WorldWideScience

Sample records for heart rate recordings

  1. Predictive value of casual ECG-based resting heart rate compared with resting heart rate obtained from Holter recording

    DEFF Research Database (Denmark)

    Carlson, Nicholas; Dixen, Ulrik; Marott, Jacob L

    2014-01-01

    BACKGROUND: Elevated resting heart rate (RHR) is associated with cardiovascular mortality and morbidity. Assessment of heart rate (HR) from Holter recording may afford a more precise estimate of the effect of RHR on cardiovascular risk, as compared to casual RHR. Comparative analysis was carried ...

  2. Validity of (Ultra-)Short Recordings for Heart Rate Variability Measurements

    NARCIS (Netherlands)

    Muñoz Venegas, Loretto; van Roon, Arie; Riese, Harriette; Thio, Chris; Oostenbroek, Emma; Westrik, Iris; de Geus, Eco J. C.; Gansevoort, Ron; Lefrandt, Joop; Nolte, Ilja M.; Snieder, Harold

    2015-01-01

    Objectives In order to investigate the applicability of routine 10s electrocardiogram (ECG) recordings for time-domain heart rate variability (HRV) calculation we explored to what extent these (ultra-)short recordings capture the "actual" HRV. Methods The standard deviation of normal-to-normal

  3. Conventional heart rate variability analysis of ambulatory electrocardiographic recordings fails to predict imminent ventricular fibrillation

    Science.gov (United States)

    Vybiral, T.; Glaeser, D. H.; Goldberger, A. L.; Rigney, D. R.; Hess, K. R.; Mietus, J.; Skinner, J. E.; Francis, M.; Pratt, C. M.

    1993-01-01

    OBJECTIVES. The purpose of this report was to study heart rate variability in Holter recordings of patients who experienced ventricular fibrillation during the recording. BACKGROUND. Decreased heart rate variability is recognized as a long-term predictor of overall and arrhythmic death after myocardial infarction. It was therefore postulated that heart rate variability would be lowest when measured immediately before ventricular fibrillation. METHODS. Conventional indexes of heart rate variability were calculated from Holter recordings of 24 patients with structural heart disease who had ventricular fibrillation during monitoring. The control group consisted of 19 patients with coronary artery disease, of comparable age and left ventricular ejection fraction, who had nonsustained ventricular tachycardia but no ventricular fibrillation. RESULTS. Heart rate variability did not differ between the two groups, and no consistent trends in heart rate variability were observed before ventricular fibrillation occurred. CONCLUSIONS. Although conventional heart rate variability is an independent long-term predictor of adverse outcome after myocardial infarction, its clinical utility as a short-term predictor of life-threatening arrhythmias remains to be elucidated.

  4. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    Science.gov (United States)

    Arras, Margarete; Rettich, Andreas; Cinelli, Paolo; Kasermann, Hans P; Burki, Kurt

    2007-01-01

    Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day) or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation. PMID:17683523

  5. Assessment of post-laparotomy pain in laboratory mice by telemetric recording of heart rate and heart rate variability

    Directory of Open Access Journals (Sweden)

    Kasermann Hans P

    2007-08-01

    Full Text Available Abstract Background Pain of mild to moderate grade is difficult to detect in laboratory mice because mice are prey animals that attempt to elude predators or man by hiding signs of weakness, injury or pain. In this study, we investigated the use of telemetry to identify indicators of mild-to-moderate post-laparotomy pain. Results Adult mice were subjected to laparotomy, either combined with pain treatment (carprofen or flunixin, 5 mg/kg s/c bid, for 1 day or without pain relief. Controls received anesthesia and analgesics or vehicle only. Telemetrically measured locomotor activity was undisturbed in all animals, thus confirming that any pain experienced was of the intended mild level. No symptoms of pain were registered in any of the groups by scoring the animals' outer appearance or spontaneous and provoked behavior. In contrast, the group receiving no analgesic treatment after laparotomy demonstrated significant changes in telemetry electrocardiogram recordings: increased heart rate and decreased heart rate variability parameters pointed to sympathetic activation and pain lasting for 24 hours. In addition, core body temperature was elevated. Body weight and food intake were reduced for 3 and 2 days, respectively. Moreover, unstructured cage territory and destroyed nests appeared for 1–2 days in an increased number of animals in this group only. In controls these parameters were not affected. Conclusion In conclusion, real-time telemetric recordings of heart rate and heart rate variability were indicative of mild-to-moderate post-laparotomy pain and could define its duration in our mouse model. This level of pain cannot easily be detected by direct observation.

  6. Fetal heart rate patterns at 20 to 24 weeks gestation as recorded by fetal electrocardiography

    Science.gov (United States)

    Hofmeyr, F; Groenewald, CA; Nel, DG; Myers, MM; Fifer, WP; Signore, C; Hankins, GDV; Odendaal, HJ

    2014-01-01

    Introduction With advancing technology it has become possible to accurately record and assess fetal heart rate (FHR) patterns from gestations as early as 20 weeks. The aim of our study was to describe early patterns of FHR, as recorded by transabdominal fetal electrocardiogram according to the Dawes-Redman criteria. Accordingly, short-term variability, basal heart rate, accelerations and decelerations were quantified at 20-24 weeks gestation among women with uncomplicated pregnancies. Methods This study was conducted in a subset of participants enrolled in a large prospective pregnancy cohort study. Our final data set consisted of 281 recordings of women with good perinatal outcomes that had undergone fetal electrocardiographic assessment as part of the Safe Passage Study. Results The success rate of the recordings was 95.4%. The mean frequency of small and large accelerations was 0.5 and 0.1 per 10 minutes respectively and that of small and large decelerations 0.3 and 0.008 per 10 minutes respectively. The mean and basal heart rates were both equal to 148.0 bpm at a median gestation of 161 days. The mean short term variation was 6.2 (SD 1.4) milliseconds and mean minute range 35.1 (SD 7.1) milliseconds. Conclusion The 20 to 24 week fetus demonstrates FHR patterns with more accelerations and decelerations, as well as higher baseline variability than was anticipated. Information from this study provides an important foundation for further, more detailed, studies of early FHR patterns. PMID:23991757

  7. Dimensional analysis of heart rate variability in heart transplant recipients

    Energy Technology Data Exchange (ETDEWEB)

    Zbilut, J.P.; Mayer-Kress, G.; Geist, K.

    1987-01-01

    We discuss periodicities in the heart rate in normal and transplanted hearts. We then consider the possibility of dimensional analysis of these periodicities in transplanted hearts and problems associated with the record.

  8. An investigation into a contactless photoplethysmographic mobile application to record heart rate post-exercise: Implications for field testing

    Directory of Open Access Journals (Sweden)

    Peart Daniel J.

    2015-08-01

    Full Text Available Study aim: the aim of this study was to compare the accuracy of a contactless photoplethysmographic mobile application (CPA to record post-exercise heart rate and estimate maximal aerobic capacity after the Queen’s College Step Test. It was hypothesised that the CPA may present a cost effective heart rate measurement tool for educators and practitioners with limited access to specialised laboratory equipment.

  9. Heart rate variability in healthy population

    International Nuclear Information System (INIS)

    Alamgir, M.; Hussain, M.M.

    2010-01-01

    Background: Heart rate variability has been considered as an indicator of autonomic status. Little work has been done on heart rate variability in normal healthy volunteers. We aimed at evolving the reference values of heart rate variability in our healthy population. Methods: Twenty-four hour holter monitoring of 37 healthy individuals was done using Holter ECG recorder 'Life card CF' from 'Reynolds Medical'. Heart rate variability in both time and frequency domains was analysed with 'Reynolds Medical Pathfinder Digital/700'. Results: The heart rate variability in normal healthy volunteers of our population was found in time domain using standard deviation of R-R intervals (SDNN), standard deviation of average NN intervals (SDANN), and Square root of the mean squared differences of successive NN intervals (RMSSD). Variation in heart rate variability indices was observed between local and foreign volunteers and RMSSD was found significantly increased (p<0.05) in local population. Conclusions: The values of heart rate variability (RMSSD) in healthy Pakistani volunteers were found increased compared to the foreign data reflecting parasympathetic dominance in our population. (author)

  10. Heating and cooling rates and their effects upon heart rate in the ...

    African Journals Online (AJOL)

    The heating and cooling rates of adult Chersina angulata were investigated to ascertain whether these tortoises can physiologically alter their rates of heat exchange. In addition, heart rates were recorded to provide an insight into the control of heat exchange. C. angulata heats significantly faster than it cools. Heart rates ...

  11. Monitoring nocturnal heart rate with bed sensor.

    Science.gov (United States)

    Migliorini, M; Kortelainen, J M; Pärkkä, J; Tenhunen, M; Himanen, S L; Bianchi, A M

    2014-01-01

    This article is part of the Focus Theme of Methods of Information in Medicine on "Biosignal Interpretation: Advanced Methods for Studying Cardiovascular and Respiratory Systems". The aim of this study is to assess the reliability of the estimated Nocturnal Heart Rate (HR), recorded through a bed sensor, compared with the one obtained from standard electrocardiography (ECG). Twenty-eight sleep deprived patients were recorded for one night each through matrix of piezoelectric sensors, integrated into the mattress, through polysomnography (PSG) simultaneously. The two recording methods have been compared in terms of signal quality and differences in heart beat detection. On average, coverage of 92.7% of the total sleep time was obtained for the bed sensor, testifying the good quality of the recordings. The average beat-to-beat error of the inter-beat intervals was 1.06%. These results suggest a good overall signal quality, however, considering fast heart rates (HR > 100 bpm), performances were worse: in fact, the sensitivity in the heart beat detection was 28.4% while the false positive rate was 3.8% which means that a large amount of fast beats were not detected. The accuracy of the measurements made using the bed sensor has less than 10% of failure rate especially in periods with HR lower than 70 bpm. For fast heart beats the uncertainty increases. This can be explained by the change in morphology of the bed sensor signal in correspondence of a higher HR.

  12. Validity of (Ultra-Short Recordings for Heart Rate Variability Measurements.

    Directory of Open Access Journals (Sweden)

    M Loretto Munoz

    Full Text Available In order to investigate the applicability of routine 10s electrocardiogram (ECG recordings for time-domain heart rate variability (HRV calculation we explored to what extent these (ultra-short recordings capture the "actual" HRV.The standard deviation of normal-to-normal intervals (SDNN and the root mean square of successive differences (RMSSD were measured in 3,387 adults. SDNN and RMSSD were assessed from (ultrashort recordings of 10s(3x, 30s, and 120s and compared to 240s-300s (gold standard measurements. Pearson's correlation coefficients (r, Bland-Altman 95% limits of agreement and Cohen's d statistics were used as agreement analysis techniques.Agreement between the separate 10s recordings and the 240s-300s recording was already substantial (r = 0.758-0.764/Bias = 0.398-0.416/d = 0.855-0.894 for SDNN; r = 0.853-0.862/Bias = 0.079-0.096/d = 0.150-0.171 for RMSSD, and improved further when three 10s periods were averaged (r = 0.863/Bias = 0.406/d = 0.874 for SDNN; r = 0.941/Bias = 0.088/d = 0.167 for RMSSD. Agreement increased with recording length and reached near perfect agreement at 120s (r = 0.956/Bias = 0.064/d = 0.137 for SDNN; r = 0.986/Bias = 0.014/d = 0.027 for RMSSD. For all recording lengths and agreement measures, RMSSD outperformed SDNN.Our results confirm that it is unnecessary to use recordings longer than 120s to obtain accurate measures of RMSSD and SDNN in the time domain. Even a single 10s (standard ECG recording yields a valid RMSSD measurement, although an average over multiple 10s ECGs is preferable. For SDNN we would recommend either 30s or multiple 10s ECGs. Future research projects using time-domain HRV parameters, e.g. genetic epidemiological studies, could calculate HRV from (ultra-short ECGs enabling such projects to be performed at a large scale.

  13. Automatic classification of transient ischaemic and transient non-ischaemic heart-rate related ST segment deviation episodes in ambulatory ECG records

    International Nuclear Information System (INIS)

    Faganeli, J; Jager, F

    2010-01-01

    In ambulatory ECG records, besides transient ischaemic ST segment deviation episodes, there are also transient non-ischaemic heart-rate related ST segment deviation episodes present, which appear only due to a change in heart rate and thus complicate automatic detection of true ischaemic episodes. The goal of this work was to automatically classify these two types of episodes. The tested features to classify the ST segment deviation episodes were changes of heart rate, changes of the Mahalanobis distance of the first five Karhunen–Loève transform (KLT) coefficients of the QRS complex, changes of time-domain morphologic parameters of the ST segment and changes of the Legendre orthonormal polynomial coefficients of the ST segment. We chose Legendre basis functions because they best fit typical shapes of the ST segment morphology, thus allowing direct insight into the ST segment morphology changes through the feature space. The classification was performed with the help of decision trees. We tested the classification method using all records of the Long-Term ST Database on all ischaemic and all non-ischaemic heart-rate related deviation episodes according to annotation protocol B. In order to predict the real-world performance of the classification we used second-order aggregate statistics, gross and average statistics, and the bootstrap method. We obtained the best performance when we combined the heart-rate features, the Mahalanobis distance and the Legendre orthonormal polynomial coefficient features, with average sensitivity of 98.1% and average specificity of 85.2%

  14. Validation of Heart Rate Monitor Polar RS800 for Heart Rate Variability Analysis During Exercise.

    Science.gov (United States)

    Hernando, David; Garatachea, Nuria; Almeida, Rute; Casajús, Jose A; Bailón, Raquel

    2018-03-01

    Hernando, D, Garatachea, N, Almeida, R, Casajús, JA, and Bailón, R. Validation of heart rate monitor Polar RS800 for heart rate variability analysis during exercise. J Strength Cond Res 32(3): 716-725, 2018-Heart rate variability (HRV) analysis during exercise is an interesting noninvasive tool to measure the cardiovascular response to the stress of exercise. Wearable heart rate monitors are a comfortable option to measure interbeat (RR) intervals while doing physical activities. It is necessary to evaluate the agreement between HRV parameters derived from the RR series recorded by wearable devices and those derived from an electrocardiogram (ECG) during dynamic exercise of low to high intensity. Twenty-three male volunteers performed an exercise stress test on a cycle ergometer. Subjects wore a Polar RS800 device, whereas ECG was also recorded simultaneously to extract the reference RR intervals. A time-frequency spectral analysis was performed to extract the instantaneous mean heart rate (HRM), and the power of low-frequency (PLF) and high-frequency (PHF) components, the latter centered on the respiratory frequency. Analysis was done in intervals of different exercise intensity based on oxygen consumption. Linear correlation, reliability, and agreement were computed in each interval. The agreement between the RR series obtained from the Polar device and from the ECG is high throughout the whole test although the shorter the RR is, the more differences there are. Both methods are interchangeable when analyzing HRV at rest. At high exercise intensity, HRM and PLF still presented a high correlation (ρ > 0.8) and excellent reliability and agreement indices (above 0.9). However, the PHF measurements from the Polar showed reliability and agreement coefficients around 0.5 or lower when the level of the exercise increases (for levels of O2 above 60%).

  15. FPGA Implementation of Heart Rate Monitoring System.

    Science.gov (United States)

    Panigrahy, D; Rakshit, M; Sahu, P K

    2016-03-01

    This paper describes a field programmable gate array (FPGA) implementation of a system that calculates the heart rate from Electrocardiogram (ECG) signal. After heart rate calculation, tachycardia, bradycardia or normal heart rate can easily be detected. ECG is a diagnosis tool routinely used to access the electrical activities and muscular function of the heart. Heart rate is calculated by detecting the R peaks from the ECG signal. To provide a portable and the continuous heart rate monitoring system for patients using ECG, needs a dedicated hardware. FPGA provides easy testability, allows faster implementation and verification option for implementing a new design. We have proposed a five-stage based methodology by using basic VHDL blocks like addition, multiplication and data conversion (real to the fixed point and vice-versa). Our proposed heart rate calculation (R-peak detection) method has been validated, using 48 first channel ECG records of the MIT-BIH arrhythmia database. It shows an accuracy of 99.84%, the sensitivity of 99.94% and the positive predictive value of 99.89%. Our proposed method outperforms other well-known methods in case of pathological ECG signals and successfully implemented in FPGA.

  16. Heart rate index

    DEFF Research Database (Denmark)

    Haedersdal, C; Pedersen, F H; Svendsen, J H

    1992-01-01

    after the myocardial infarction. A significant correlation (Spearman's correlation coefficient rs, p less than 0.05) was found between LVEF at rest and the following variables assessed at exercise test: 1) the heart rate at rest, 2) rise in heart rate, 3) ratio between maximal heart rate and heart rate...... at rest, 4) rise in systolic blood pressure, 5) rate pressure product at rest, 6) rise in rate pressure product, 7) ratio (rHR) between maximal rate pressure product and rate pressure product at rest, 8) total exercise time. The heart rate was corrected for effects caused by age (heart index (HR...

  17. Effects of Malaria on Blood Pressure, Heart Rate, Electrocardiogram ...

    African Journals Online (AJOL)

    The effect of malaria on blood pressure, heart rate, electrocardiogram and the cardiovascular responses to postural change were studied in malaria patients. Blood pressure was measured by the sphygmomanometric-auscultatory method. Standard ECG machine was used to record the electrocardiogram. Heart rate was ...

  18. Comparison of energy expenditure by the doubly labeled water technique with energy intake, heart rate, and activity recording in man

    International Nuclear Information System (INIS)

    Schulz, S.; Westerterp, K.R.; Brueck, K.

    1989-01-01

    Average daily energy expenditure determined by the doubly labeled water technique (dlwEE) was compared in six subjects (aged 20-30 y) over 2 wk under usual living conditions; average food energy intake and energy expenditure estimated from individual diary records of physical activity. In addition, energy expenditure was estimated from 24-h heart rate recordings carried out on two randomly chosen days of the 2-wk period. The group means of the dlwEE were 1.94 +/- 0.24 (means +/- SD) times larger than resting metabolic rate (= 1.94 met) and nearly identical to the average daily energy intake (1.93 +/- 0.23 met). Energy expenditure estimated from the diaries of activity and from the 24-h heart rate recording varied between 1.67 and 2.24 met depending on the calculation procedure. The dlwEE (1.94 +/- 0.24 met) is much higher than that recently determined for sedentary people (1.25 met) and thus explains that young students may achieve body weight balance with a relatively high daily food energy intake

  19. The reliability and accuracy of estimating heart-rates from RGB video recorded on a consumer grade camera

    Science.gov (United States)

    Eaton, Adam; Vincely, Vinoin; Lloyd, Paige; Hugenberg, Kurt; Vishwanath, Karthik

    2017-03-01

    Video Photoplethysmography (VPPG) is a numerical technique to process standard RGB video data of exposed human skin and extracting the heart-rate (HR) from the skin areas. Being a non-contact technique, VPPG has the potential to provide estimates of subject's heart-rate, respiratory rate, and even the heart rate variability of human subjects with potential applications ranging from infant monitors, remote healthcare and psychological experiments, particularly given the non-contact and sensor-free nature of the technique. Though several previous studies have reported successful correlations in HR obtained using VPPG algorithms to HR measured using the gold-standard electrocardiograph, others have reported that these correlations are dependent on controlling for duration of the video-data analyzed, subject motion, and ambient lighting. Here, we investigate the ability of two commonly used VPPG-algorithms in extraction of human heart-rates under three different laboratory conditions. We compare the VPPG HR values extracted across these three sets of experiments to the gold-standard values acquired by using an electrocardiogram or a commercially available pulseoximeter. The two VPPG-algorithms were applied with and without KLT-facial feature tracking and detection algorithms from the Computer Vision MATLAB® toolbox. Results indicate that VPPG based numerical approaches have the ability to provide robust estimates of subject HR values and are relatively insensitive to the devices used to record the video data. However, they are highly sensitive to conditions of video acquisition including subject motion, the location, size and averaging techniques applied to regions-of-interest as well as to the number of video frames used for data processing.

  20. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography

    Directory of Open Access Journals (Sweden)

    Thomas Penzel

    2016-10-01

    Full Text Available The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG and cardio-respiratory couplings in a chronological (historical sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave.

  1. Modulations of Heart Rate, ECG, and Cardio-Respiratory Coupling Observed in Polysomnography.

    Science.gov (United States)

    Penzel, Thomas; Kantelhardt, Jan W; Bartsch, Ronny P; Riedl, Maik; Kraemer, Jan F; Wessel, Niels; Garcia, Carmen; Glos, Martin; Fietze, Ingo; Schöbel, Christoph

    2016-01-01

    The cardiac component of cardio-respiratory polysomnography is covered by ECG and heart rate recordings. However, their evaluation is often underrepresented in summarizing reports. As complements to EEG, EOG, and EMG, these signals provide diagnostic information for autonomic nervous activity during sleep. This review presents major methodological developments in sleep research regarding heart rate, ECG, and cardio-respiratory couplings in a chronological (historical) sequence. It presents physiological and pathophysiological insights related to sleep medicine obtained by new technical developments. Recorded nocturnal ECG facilitates conventional heart rate variability (HRV) analysis, studies of cyclical variations of heart rate, and analysis of ECG waveform. In healthy adults, the autonomous nervous system is regulated in totally different ways during wakefulness, slow-wave sleep, and REM sleep. Analysis of beat-to-beat heart-rate variations with statistical methods enables us to estimate sleep stages based on the differences in autonomic nervous system regulation. Furthermore, up to some degree, it is possible to track transitions from wakefulness to sleep by analysis of heart-rate variations. ECG and heart rate analysis allow assessment of selected sleep disorders as well. Sleep disordered breathing can be detected reliably by studying cyclical variation of heart rate combined with respiration-modulated changes in ECG morphology (amplitude of R wave and T wave).

  2. Heart rate variability among caregivers of chronically bedridden patients

    Directory of Open Access Journals (Sweden)

    Amrith Pakkala

    2013-01-01

    Full Text Available Background: Caregivers of chronically bedridden patients are likely to suffer from mental and physical exhaustion leading to stress. This is important in view of the prevailing socioeconomic as well as the healthcare system available in a developing country like India. Therefore, the present study is designed to measure heart rate variability (HRV among this special group of population who give care to long-term bedridden patients. Materials and Methods: Fifteen female subjects were enrolled from among attendants of patients admitted with an immediate history of a cerebrovascular accident with locomotor deficits, who required constant care. They were free from any type of physical and mental health issues, nonsmokers and nonaddicts. Each care giver was subjected to HRV analysis on three occasions: The first record was performed in the 1 st week of their arrival in the hospital as caregivers. The second observation was recorded after 3 months of caregiving. The final HRV analysis was done after 6 months of care giving. Two types of parameters were analyzed: Time domain and frequency domain. Statistical analysis was done using paired t-test. Results: Both the HRV parameters: Time and frequency domain, showed decreased values during the 3 rd and 6 th month recording as compared to the 1 st week recording. The decrease is much more during the 6 th month recording as compared to the 3 rd month recording. Statistically significant decrease is observed in mean RR interval, heart rate, very low frequency (VLF, and LF only when the 1 st week recording is compared with the 3 rd month recording, but when the 1 st week recording was compared with the 6 th month recording significant decrease was found in mean RR interval and heart rate. Conclusion: Subjects involved in taking care of chronically ill bedridden patients are likely to undergo a lot of physical and mental stress, thus affecting their autonomic status. HRV analysis using short term

  3. "Heart rate-dependent" electrocardiographic diagnosis of left ventricular hypertrophy.

    Science.gov (United States)

    Madias, John E

    2013-05-01

    A case is presented revealing the common phenomenon of heart rate-dependent diagnosis of electrocardiographic (ECG) diagnosis of left ventricular hypertrophy (LVH), which consists of satisfaction of LVH criteria only at faster rates whereas ECGs with a slow heart rate do not satisfy such criteria. The mechanism of the phenomenon has been attributed to the tachycardia-mediated underfilling of the left ventricle bringing the electrical "centroid" of the heart closer to the recording electrodes, which results in augmentation of the amplitude of QRS complexes, particularly in leads V2-V4. ©2012, The Author. Journal compilation ©2012 Wiley Periodicals, Inc.

  4. Heart Rate Variability - A Historical Perspective

    Directory of Open Access Journals (Sweden)

    George E Billman

    2011-11-01

    Full Text Available Heart rate variability (HRV, the beat-to-beat variation in either heart rate or the duration of the R-R interval – the heart period, has become a popular clinical and investigational tool. The temporal fluctuations in heart rate exhibit a marked synchrony with respiration (increasing during inspiration and decreasing during expiration – the so called respiratory sinus arrhythmia, RSA and are widely believed to reflect changes in cardiac autonomic regulation. Although the exact contributions of the parasympathetic and the sympathetic divisions of the autonomic nervous system to this variability are controversial and remain the subject of active investigation and debate, a number of time and frequency domain techniques have been developed to provide insight into cardiac autonomic regulation in both health and disease. It is the purpose of this essay to provide an historical overview of the evolution in the concept of heart rate variability. Briefly, pulse rate was first measured by ancient Greek physicians and scientists. However, it was not until the invention of the Physician’s Pulse Watch (a watch with a second hand that could be stopped in 1707 that changes in pulse rate could be accurately assessed. The Rev. Stephen Hales (1733 was the first to note that pulse varied with respiration and in 1847 Carl Ludwig was the first to record RSA. With the measurement of the ECG (1895 and advent of digital signal processing techniques in the 1960’s, investigation of HRV and its relationship to health and disease has exploded. This essay will conclude with a brief description of time domain, frequency domain, and non-linear dynamic analysis techniques (and their limitations that are commonly used to measure heart rate variability.

  5. Influence of heavy cigarette smoking on heart rate variability and heart rate turbulence parameters

    DEFF Research Database (Denmark)

    Cagirci, Goksel; Cay, Serkan; Karakurt, Ozlem

    2009-01-01

    BACKGROUND: Cigarette smoking increases the risk of cardiovascular events related with several mechanisms. The most suggested mechanism is increased activity of sympathetic nervous system. Heart rate variability (HRV) and heart rate turbulence (HRT) has been shown to be independent and powerful......, 69 subjects and nonsmokers 74 subjects (control group) were enrolled in this study. HRV and HRT analyses [turbulence onset (TO) and turbulence slope (TS)] were assessed from 24-hour Holter recordings. RESULTS: The values of TO were significantly higher in heavy cigarette smokers than control group...... (-1.150 +/- 4.007 vs -2.454 +/- 2.796, P = 0.025, respectively), but values of TS were not statistically different between two groups (10.352 +/- 7.670 vs 9.613 +/- 7.245, P = 0.555, respectively). Also, the number of patients who had abnormal TO was significantly higher in heavy cigarette smokers...

  6. Design of heart rate monitor based on piezoelectric sensor using an Arduino

    Science.gov (United States)

    Setyowati, Veni; Muninggar, Jodelin; Shanti. N. A, Made R. S.

    2017-01-01

    Reading of result heart rate using an acoustic stethoscope needs a particular skill, quiet environment, and hearing sensitivity. This project had the purpose design of a user-friendly automatic heart rate monitor and especially in a noisy area which to eliminate problems and incorrect reading of result. The liquid crystal display shows a heart rate as a result of measurements. The design of the heart rate monitor has two main parts; the signal recorder that a piezoelectric sensor, a filter, and an amplifier as recorder. The second parts was Arduino microcontroller with reinforced. Besides, three supporting buttons provided as the manual switches, the ‘on’, the ‘start’, and ‘reset’ buttons. The values acquired from the heart rate monitor indicate that those were on the Vernier BPS-BTA value range. The measurement error factor of the heart rate monitor then compared to the Vernier BPS-BTA test device was 3.15%. Besides, the value of statistical independent-test indicates that there is no significant difference (P = 0.971) between the heart rate monitor device and the Vernier BPS-BTA. In conclusion, this device was ready to be used because it has almost the same accuracy with the standart device.

  7. The effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multislice computed tomography angiography

    International Nuclear Information System (INIS)

    Tuyyab, F.; Naeem, M.Y.; Maken, G.R.; Najfi, M.H.; Hassan, F.

    2012-01-01

    Objective: The purpose of this study was to determine the effect of metaprolol alone and metaprolol plus bromazepam on heart rate and heart rate variability during multi slice computed tomography (MSCT) angiography. Methodology: This was a Double blind randomized controlled trial was conducted at AFIC/NIHD, Rawalpindi, from May 2011 to November 2011. Patients undergoing first MSCT angiography meeting inclusion criteria with heart rates (HR) more than 80 beats/min were included. Patients were randomized in to two groups using random numbers table. Group 1 was administered metaprolol plus placebo while group 2 was administered metaprolol plus bromazepam one hour before the scan. Both groups had scans under strictly similar conditions. HR before and during scan along with heart rate variability (HRV) were recorded. Results: A total of 80 patients were included. Patients mean age was 49 + 13, 57 % were males while 43 % were females. Risk factor profile was similar in both groups. HR reduction in group 1 was 15+ 6.0 and in group 2, was 21+9.0 (p= 0.002). HRV in group 1 was 3.9 + 1.32 and in group 2 was 2.3 + 1.0 (p= 0.003). Group 2 had significantly lower HR and significantly less HRV as compared with group 1. Conclusion: Combination of bromazepam and metaprolol results in significant and further reduction in heart rate and heart rate variability than metaprolol alone. Both drugs can be used together for a better control of heart rate and heart rate variability during MSCT angiography for improving the quality of images. (author)

  8. Time-motion analysis and heart rate recordings of South African ...

    African Journals Online (AJOL)

    The objective of this study was to determine the movement patterns, heart rates and work-to-rest ratios of South African Rugby Union referees during the two halves of match-refereeing. The referees were monitored by means of a video camera in 16 matches during a tournament. The frequency and duration of the different ...

  9. Determination of heart rate variability with an electronic stethoscope.

    Science.gov (United States)

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  10. Effects of Liraglutide on Heart Rate and Heart Rate Variability

    DEFF Research Database (Denmark)

    Kumarathurai, Preman; Anholm, Christian; Larsen, Bjørn Strøier

    2017-01-01

    OBJECTIVE: Reduced heart rate variability (HRV) and increased heart rate (HR) have been associated with cardiovascular mortality. Glucagon-like peptide 1 receptor agonists (GLP-1 RAs) increase HR, and studies have suggested that they may reduce HRV. We examined the effect of the GLP-1 RA...

  11. Change of Diurnal Heart Rate Patterns During Pregnancy and Lactation in Dogs (Canis familiaris

    Directory of Open Access Journals (Sweden)

    Häggström J

    2003-09-01

    Full Text Available Pregnancy and lactation involve great demands on the cardiovascular system. The purpose of this study was to investigate how the heart rate and diurnal heart rate pattern change when dogs become pregnant or lactate. Five clinically healthy female beagle dogs were mated, and delivered three to seven healthy puppies. The heart rate was investigated with 24-h ECG (Holter once during anoestrus, at 3, 5, 7 and 9 weeks of pregnancy, and at week 4 postpartum (lactation. However, at 9 weeks, the ECG could not be recorded for the fully 24 h in 4 of 5 dogs, because labour started and the dogs then appeared disturbed by the recordings. The results at this date are not included in the statistical comparison. The heart rate increased progressively during pregnancy and was still elevated at 4 weeks of lactation. During late pregnancy the difference in heart rates between daytime and nighttime became smaller, but the heart rate was significantly higher in daytime in all periods. In conclusion, the increased heart rates during pregnancy and lactation reflect increased demands on the cardiovascular system and may be important to consider in clinical practice.

  12. Automatic evaluation of intrapartum fetal heart rate recordings: a comprehensive analysis of useful features.

    Science.gov (United States)

    Chudáček, V; Spilka, J; Janků, P; Koucký, M; Lhotská, L; Huptych, M

    2011-08-01

    Cardiotocography is the monitoring of fetal heart rate (FHR) and uterine contractions (TOCO), used routinely since the 1960s by obstetricians to detect fetal hypoxia. The evaluation of the FHR in clinical settings is based on an evaluation of macroscopic morphological features and so far has managed to avoid adopting any achievements from the HRV research field. In this work, most of the features utilized for FHR characterization, including FIGO, HRV, nonlinear, wavelet, and time and frequency domain features, are investigated and assessed based on their statistical significance in the task of distinguishing the FHR into three FIGO classes. We assess the features on a large data set (552 records) and unlike in other published papers we use three-class expert evaluation of the records instead of the pH values. We conclude the paper by presenting the best uncorrelated features and their individual rank of importance according to the meta-analysis of three different ranking methods. The number of accelerations and decelerations, interval index, as well as Lempel-Ziv complexity and Higuchi's fractal dimension are among the top five features.

  13. Automatic evaluation of intrapartum fetal heart rate recordings: a comprehensive analysis of useful features

    International Nuclear Information System (INIS)

    Chudáček, V; Spilka, J; Lhotská, L; Huptych, M; Janků, P; Koucký, M

    2011-01-01

    Cardiotocography is the monitoring of fetal heart rate (FHR) and uterine contractions (TOCO), used routinely since the 1960s by obstetricians to detect fetal hypoxia. The evaluation of the FHR in clinical settings is based on an evaluation of macroscopic morphological features and so far has managed to avoid adopting any achievements from the HRV research field. In this work, most of the features utilized for FHR characterization, including FIGO, HRV, nonlinear, wavelet, and time and frequency domain features, are investigated and assessed based on their statistical significance in the task of distinguishing the FHR into three FIGO classes. We assess the features on a large data set (552 records) and unlike in other published papers we use three-class expert evaluation of the records instead of the pH values. We conclude the paper by presenting the best uncorrelated features and their individual rank of importance according to the meta-analysis of three different ranking methods. The number of accelerations and decelerations, interval index, as well as Lempel–Ziv complexity and Higuchi's fractal dimension are among the top five features

  14. QRS peak detection for heart rate monitoring on Android smartphone

    Science.gov (United States)

    Pambudi Utomo, Trio; Nuryani, Nuryani; Darmanto

    2017-11-01

    In this study, Android smartphone is used for heart rate monitoring and displaying electrocardiogram (ECG) graph. Heart rate determination is based on QRS peak detection. Two methods are studied to detect the QRS complex peak; they are Peak Threshold and Peak Filter. The acquisition of ECG data is utilized by AD8232 module from Analog Devices, three electrodes, and Microcontroller Arduino UNO R3. To record the ECG data from a patient, three electrodes are attached to particular body’s surface of a patient. Patient’s heart activity which is recorded by AD8232 module is decoded by Arduino UNO R3 into analog data. Then, the analog data is converted into a voltage value (mV) and is processed to get the QRS complex peak. Heart rate value is calculated by Microcontroller Arduino UNO R3 uses the QRS complex peak. Voltage, heart rate, and the QRS complex peak are sent to Android smartphone by Bluetooth HC-05. ECG data is displayed as the graph by Android smartphone. To evaluate the performance of QRS complex peak detection method, three parameters are used; they are positive predictive, accuracy and sensitivity. Positive predictive, accuracy, and sensitivity of Peak Threshold method is 92.39%, 70.30%, 74.62% and for Peak Filter method are 98.38%, 82.47%, 83.61%, respectively.

  15. Heart rate monitoring mobile applications

    OpenAIRE

    Chaudhry, Beenish M.

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone?s camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, ?Unique Heart Rate Monitor?, you can also maintain your heart rate history for personal ...

  16. Heart rate turbulence after ventricular premature beats in healthy Doberman pinschers and those with dilated cardiomyopathy.

    Science.gov (United States)

    Harris, J D; Little, C J L; Dennis, J M; Patteson, M W

    2017-10-01

    To describe the measurement of heart rate turbulence (HRT) after ventricular premature beats and compare HRT in healthy Doberman pinschers and those with dilated cardiomyopathy (DCM), with and without congestive heart failure (CHF). Sixty-five client-owned Dobermans: 20 healthy (NORMAL), 31 with preclinical DCM and 14 with DCM and CHF (DCM + CHF). A retrospective study of data retrieved from clinical records and ambulatory ECG (Holter) archives, including data collected previously for a large-scale prospective study of Dobermans with preclinical DCM. Holter data were reanalysed quantitatively, including conventional time-domain heart rate variability and the HRT parameters turbulence onset and turbulence slope. Heart rate turbulence could be measured in 58/65 dogs. Six Holter recordings had inadequate ventricular premature contractions (VPCs) and one exhibited VPCs too similar to sinus morphology. Heart rate turbulence parameter, turbulence onset, was significantly reduced in DCM dogs, whereas conventional heart rate variability measures were not. Heart rate variability and HRT markers were reduced in DCM + CHF dogs as expected. Heart rate turbulence can be measured from the majority of good quality standard canine 24-hour Holter recordings with >5 VPCs. Turbulence onset is significantly reduced in Dobermans with preclinical DCM which indicates vagal withdrawal early in the course of disease. Heart rate turbulence is a powerful prognostic indicator in human cardiac disease which can be measured from standard 24-hour ambulatory ECG (Holter) recordings using appropriate computer software. Further studies are warranted to assess whether HRT may be of prognostic value in dogs with preclinical DCM and in other canine cardiac disease. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Heart rate monitoring mobile applications.

    Science.gov (United States)

    Chaudhry, Beenish M

    2016-01-01

    Total number of times a heart beats in a minute is known as the heart rate. Traditionally, heart rate was measured using clunky gadgets but these days it can be measured with a smartphone's camera. This can help you measure your heart rate anywhere and at anytime, especially during workouts so you can adjust your workout intensity to achieve maximum health benefits. With simple and easy to use mobile app, 'Unique Heart Rate Monitor', you can also maintain your heart rate history for personal reflection and sharing with a provider.

  18. Music close to one's heart: heart rate variability with music, diagnostic with e-bra and smartphone

    Science.gov (United States)

    Hegde, Shantala; Kumar, Prashanth S.; Rai, Pratyush; Mathur, Gyanesh N.; Varadan, Vijay K.

    2012-04-01

    Music is a powerful elicitor of emotions. Emotions evoked by music, through autonomic correlates have been shown to cause significant modulation of parameters like heart rate and blood pressure. Consequently, Heart Rate Variability (HRV) analysis can be a powerful tool to explore evidence based therapeutic functions of music and conduct empirical studies on effect of musical emotion on heart function. However, there are limitations with current studies. HRV analysis has produced variable results to different emotions evoked via music, owing to variability in the methodology and the nature of music chosen. Therefore, a pragmatic understanding of HRV correlates of musical emotion in individuals listening to specifically chosen music whilst carrying out day to day routine activities is needed. In the present study, we aim to study HRV as a single case study, using an e-bra with nano-sensors to record heart rate in real time. The e-bra developed previously, has several salient features that make it conducive for this study- fully integrated garment, dry electrodes for easy use and unrestricted mobility. The study considers two experimental conditions:- First, HRV will be recorded when there is no music in the background and second, when music chosen by the researcher and by the subject is playing in the background.

  19. Heart rate variability - a historical perspective.

    Science.gov (United States)

    Billman, George E

    2011-01-01

    Heart rate variability (HRV), the beat-to-beat variation in either heart rate or the duration of the R-R interval - the heart period, has become a popular clinical and investigational tool. The temporal fluctuations in heart rate exhibit a marked synchrony with respiration (increasing during inspiration and decreasing during expiration - the so called respiratory sinus arrhythmia, RSA) and are widely believed to reflect changes in cardiac autonomic regulation. Although the exact contributions of the parasympathetic and the sympathetic divisions of the autonomic nervous system to this variability are controversial and remain the subject of active investigation and debate, a number of time and frequency domain techniques have been developed to provide insight into cardiac autonomic regulation in both health and disease. It is the purpose of this essay to provide an historical overview of the evolution in the concept of HRV. Briefly, pulse rate was first measured by ancient Greek physicians and scientists. However, it was not until the invention of the "Physician's Pulse Watch" (a watch with a second hand that could be stopped) in 1707 that changes in pulse rate could be accurately assessed. The Rev. Stephen Hales (1733) was the first to note that pulse varied with respiration and in 1847 Carl Ludwig was the first to record RSA. With the measurement of the ECG (1895) and advent of digital signal processing techniques in the 1960s, investigation of HRV and its relationship to health and disease has exploded. This essay will conclude with a brief description of time domain, frequency domain, and non-linear dynamic analysis techniques (and their limitations) that are commonly used to measure HRV.

  20. Heart rate response to breathing

    DEFF Research Database (Denmark)

    Mehlsen, J; Pagh, K; Nielsen, J S

    1987-01-01

    Heart rate responses to stepwise and periodic changes in lung volume were studied in seven young healthy males. Stepwise inspiration and expiration both resulted in an increase in heart rate followed by a rapid decrease in heart rate. The fastest heart rate was reached in 1.6 +/- 0.5 s and in 3.......6 +/- 1.4 s in response to inspiration and expiration, respectively (P less than 0.01). The slowest heart rate was reached in 4.8 +/- 1.0 s and in 7.6 +/- 1.9 s in response to inspiration and expiration, respectively (P less than 0.01). Following this biphasic change the heart rate returned to a steady...... level. The difference between the fastest and the slowest heart rates was significantly larger in response to inspiration (21.7 +/- 7.3 beats per minute) than in response to expiration (12.0 +/- 7.3 beats per minute; P less than 0.01). Periodic changes in lung volume were performed with frequencies from...

  1. Probability of detection of clinical seizures using heart rate changes.

    Science.gov (United States)

    Osorio, Ivan; Manly, B F J

    2015-08-01

    Heart rate-based seizure detection is a viable complement or alternative to ECoG/EEG. This study investigates the role of various biological factors on the probability of clinical seizure detection using heart rate. Regression models were applied to 266 clinical seizures recorded from 72 subjects to investigate if factors such as age, gender, years with epilepsy, etiology, seizure site origin, seizure class, and data collection centers, among others, shape the probability of EKG-based seizure detection. Clinical seizure detection probability based on heart rate changes, is significantly (pprobability of detecting clinical seizures (>0.8 in the majority of subjects) using heart rate is highest for complex partial seizures, increases with a patient's years with epilepsy, is lower for females than for males and is unrelated to the side of hemisphere origin. Clinical seizure detection probability using heart rate is multi-factorially dependent and sufficiently high (>0.8) in most cases to be clinically useful. Knowledge of the role that these factors play in shaping said probability will enhance its applicability and usefulness. Heart rate is a reliable and practical signal for extra-cerebral detection of clinical seizures originating from or spreading to central autonomic network structures. Copyright © 2015 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  2. Validity of a heart rate monitor during work in the laboratory and on the Space Shuttle

    Science.gov (United States)

    Moore, A. D. Jr; Lee, S. M.; Greenisen, M. C.; Bishop, P.

    1997-01-01

    Accurate heart rate measurement during work is required for many industrial hygiene and ergonomics situations. The purpose of this investigation was to determine the validity of heart rate measurements obtained by a simple, lightweight, commercially available wrist-worn heart rate monitor (HRM) during work (cycle exercise) sessions conducted in the laboratory and also during the particularly challenging work environment of space flight. Three different comparisons were made. The first compared HRM data to simultaneous electrocardiogram (ECG) recordings of varying heart rates that were generated by an ECG simulator. The second compared HRM data to ECG recordings collected during work sessions of 14 subjects in the laboratory. Finally, ECG downlink and HRM data were compared in four astronauts who performed cycle exercise during space flight. The data were analyzed using regression techniques. The results were that the HRM recorded virtually identical heart rates compared with ECG recordings for the data set generated by an ECG simulator. The regression equation for the relationship between ECG versus HRM heart rate data during work in the laboratory was: ECG HR = 0.99 x (HRM) + 0.82 (r2 = 0.99). Finally, the agreement between ECG downlink data and HRM data during space flight was also very high, with the regression equation being: Downlink ECG HR = 1.05 x (HRM) -5.71 (r2 = 0.99). The results of this study indicate that the HRM provides accurate data and may be used to reliably obtain valid data regarding heart rate responses during work.

  3. Approximate entropy and point correlation dimension of heart rate variability in healthy subjects

    DEFF Research Database (Denmark)

    Storella, R J; Wood, H W; Mills, K M

    1999-01-01

    The contribution of nonlinear dynamics to heart rate variability in healthy humans was examined using surrogate data analysis. Several measures of heart rate variability were used and compared. Heart rates were recorded for three hours and original data sets of 8192 R-R intervals created. For each...... original data set (n = 34), three surrogate data sets were made by shuffling the order of the R-R intervals while retaining their linear correlations. The difference in heart rate variability between the original and surrogate data sets reflects the amount of nonlinear structure in the original data set....... Heart rate variability was analyzed by two different nonlinear methods, point correlation dimension and approximate entropy. Nonlinearity, though under 10 percent, could be detected with both types of heart rate variability measures. More importantly, not only were the correlations between...

  4. Effects of hot-iron branding on heart rate, breathing rate and behaviour of anaesthetised Steller sea lions.

    Science.gov (United States)

    Walker, K A; Mellish, J E; Weary, D M

    2011-10-01

    This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.

  5. Spectral analysis of time series of events: effect of respiration on heart rate in neonates

    International Nuclear Information System (INIS)

    Van Drongelen, Wim; Williams, Amber L; Lasky, Robert E

    2009-01-01

    Certain types of biomedical processes such as the heart rate generator can be considered as signals that are sampled by the occurring events, i.e. QRS complexes. This sampling property generates problems for the evaluation of spectral parameters of such signals. First, the irregular occurrence of heart beats creates an unevenly sampled data set which must either be pre-processed (e.g. by using trace binning or interpolation) prior to spectral analysis, or analyzed with specialized methods (e.g. Lomb's algorithm). Second, the average occurrence of events determines the Nyquist limit for the sampled time series. Here we evaluate different types of spectral analysis of recordings of neonatal heart rate. Coupling between respiration and heart rate and the detection of heart rate itself are emphasized. We examine both standard and data adaptive frequency bands of heart rate signals generated by models of coupled oscillators and recorded data sets from neonates. We find that an important spectral artifact occurs due to a mirror effect around the Nyquist limit of half the average heart rate. Further we conclude that the presence of respiratory coupling can only be detected under low noise conditions and if a data-adaptive respiratory band is used

  6. Heart rate variability analysis in healthy subjects, patients suffering from congestive heart failure and heart transplanted patients

    Directory of Open Access Journals (Sweden)

    Argentina Leite

    2013-12-01

    Full Text Available This study aimed to find parameters to characterize heart rate variability (HRV and discriminate healthy subjects and patients with heart diseases. The parameters used for discrimination characterize the different components of HRV memory (short and long and are extracted from HRV recordings using parametric as well as non parametric methods. Thus, the parameters are: spectral components at low frequencies (LH and high frequencies (HF which are associated with the short memory of HRV and the long memory parameter (d obtained from autoregressive fractionally integrated moving average (ARFIMA models. In the non parametric context, short memory (α1 and long memory (α2 parameters are obtained from detrended fluctuation analysis (DFA. The sample used in this study contains 24-hour Holter HRV recordings of 30 subjects: 10 healthy individuals, 10 patients suffering from congestive heart failure and 10 heart transplanted patients from the Noltisalis database. It was found that short memory parameters present higher values for the healthy individuals whereas long memory parameters present higher values for the diseased individuals. Moreover, there is evidence that ARFIMA modeling allows the discrimination between the 3 groups under study, being advantageous over DFA.

  7. Smartphone-based photoplethysmographic imaging for heart rate monitoring.

    Science.gov (United States)

    Alafeef, Maha

    2017-07-01

    The purpose of this study is to make use of visible light reflected mode photoplethysmographic (PPG) imaging for heart rate (HR) monitoring via smartphones. The system uses the built-in camera feature in mobile phones to capture video from the subject's index fingertip. The video is processed, and then the PPG signal resulting from the video stream processing is used to calculate the subject's heart rate. Records from 19 subjects were used to evaluate the system's performance. The HR values obtained by the proposed method were compared with the actual HR. The obtained results show an accuracy of 99.7% and a maximum absolute error of 0.4 beats/min where most of the absolute errors lay in the range of 0.04-0.3 beats/min. Given the encouraging results, this type of HR measurement can be adopted with great benefit, especially in the conditions of personal use or home-based care. The proposed method represents an efficient portable solution for HR accurate detection and recording.

  8. New descriptors of T-wave morphology are independent of heart rate

    DEFF Research Database (Denmark)

    Andersen, Mads Peter; Xue, Joel Q; Graff, Claus

    2008-01-01

    from daytime Holter recordings. Duration parameters (QT, ToTe, TpTe, and others), a number of basic T-wave morphology parameters (amplitude, area, and others) as well as advanced morphology descriptors (asymmetry, flatness, and others) were measured automatically. Heart rate dependence was examined...... by means of analysis of covariance. The results showed clear heart rate dependence for the QT interval (R(2) = 0.53-0.57) and a moderate degree of heart rate dependence for the basic morphology parameters (amplitude, area, and others) (R(2) = 0.17-0.42). Both the advanced T-wave descriptors (asymmetry......T-wave morphology descriptors are sensitive to drug-induced changes and may be a useful addition to the QT interval in cardiac safety trials. Intrasubject heart rate dependence of T-wave morphology was investigated in a sample of 39 healthy individuals. Ten-second electrocardiograms were obtained...

  9. Evaluation of sympathetic nerve system activity with MIBG. Comparison with heart rate variability

    International Nuclear Information System (INIS)

    Kurata, Chinori; Wakabayashi, Yasushi; Shouda, Sakae; Mikami, Tadashi; Tawarahara, Kei; Sugiyama, Tsuyoshi; Nakano, Tomoyasu; Suzuki, Toshihiko.

    1997-01-01

    Authors attempted to elucidate the relations of plasma concentration of norepinephrine (pNE) and findings of heart rate variability and MIBG myocardial scintigraphy and evaluated cardiac autonomic nervous activity in chronic renal failure. Subjects were 211 patients with various heart diseases (coronary artery lesion, cardiomyopathy, hypertension, diabetes mellitus, renal failure and so on), 60 patients with artificial kidney due to chronic renal failure, 13 of whom were found to have coronary arterial disease by Tl myocardial scintigraphy, and 14 normal volunteers. ECG was recorded with the portable recorder for heart rate variability. Together with collection of blood for pNE measurement, myocardial scintigraphy was done at 15 and 150 min after intravenous administration of 111 MBq of MIBG for acquisition of early and delayed, respectively, images of the frontal breast. Accumulation at and elimination during the time points of MIBG were computed in cps unit. Variability of heart rate was found to have the correlation positive with MIBG delayed accumulation and negative with the elimination, and pNE, negative with heart rate variability and the delayed accumulation and positive with the elimination. Thus cardiac autonomic nervous abnormality was suggested to occur before uremic cardiomyopathy. (K.H.)

  10. Is 10-second electrocardiogram recording enough for accurately estimating heart rate in atrial fibrillation.

    Science.gov (United States)

    Shuai, Wei; Wang, Xi-Xing; Hong, Kui; Peng, Qiang; Li, Ju-Xiang; Li, Ping; Chen, Jing; Cheng, Xiao-Shu; Su, Hai

    2016-07-15

    At present, the estimation of rest heart rate (HR) in atrial fibrillation (AF) is obtained by apical auscultation for 1min or on the surface electrocardiogram (ECG) by multiplying the number of RR intervals on the 10second recording by six. But the reasonability of 10second ECG recording is controversial. ECG was continuously recorded at rest for 60s to calculate the real rest HR (HR60s). Meanwhile, the first 10s and 30s ECG recordings were used for calculating HR10s (sixfold) and HR30s (twofold). The differences of HR10s or HR30s with the HR60s were compared. The patients were divided into three sub-groups on the HR60s 100bpm. No significant difference among the mean HR10s, HR30s and HR60s was found. A positive correlation existed between HR10s and HR60s or HR30s and HR60s. Bland-Altman plot showed that the 95% reference limits were high as -11.0 to 16.0bpm for HR10s, but for HR30s these values were only -4.5 to 5.2bpm. Among the three subgroups with HR60s 100bpm, the 95% reference limits with HR60s were -8.9 to 10.6, -10.5 to 14.0 and -11.3 to 21.7bpm for HR10s, but these values were -3.9 to 4.3, -4.1 to 4.6 and -5.3 to 6.7bpm for HR30s. As 10s ECG recording could not provide clinically accepted estimation HR, ECG should be recorded at least for 30s in the patients with AF. It is better to record ECG for 60s when the HR is rapid. Copyright © 2016. Published by Elsevier Ireland Ltd.

  11. AUTONOMIC CONTROL OF HEART RATE AFTER EXERCISE IN TRAINED WRESTLERS

    Directory of Open Access Journals (Sweden)

    Carlos F Henríquez

    2013-04-01

    Full Text Available The objective of this study was to establish differences in vagal reactivation, through heart rate recovery and heart rate variability post exercise, in Brazilian jiu-jitsu wrestlers (BJJW. A total of 18 male athletes were evaluated, ten highly trained (HT and eight moderately trained (MT, who performed a maximum incremental test. At the end of the exercise, the R-R intervals were recorded during the first minute of recovery. We calculated heart rate recovery (HRR60s, and performed linear and non-linear (standard deviation of instantaneous beat-to-beat R-R interval variability – SD1 analysis of heart rate variability (HRV, using the tachogram of the first minute of recovery divided into four segments of 15 s each (0-15 s, 15-30 s, 30-45 s, 45-60 s. Between HT and MT individuals, there were statistically significant differences in HRR60s (p <0.05 and in the non linear analysis of HRV from SD130-45s (p <0.05 and SD145-60s (p <0.05. The results of this research suggest that heart rate kinetics during the first minute after exercise are related to training level and can be used as an index for autonomic cardiovascular control in BJJW.

  12. Age-related disappearance of Mayer-like heart rate waves

    Science.gov (United States)

    Jarisch, W. R.; Ferguson, J. J.; Shannon, R. P.; Wei, J. Y.; Goldberger, A. L.

    1987-01-01

    The effect of age on the principal spectral components of heart rate obtained immediately after passive upright tilt was investigated in human subjects who underwent a 60-deg tilt over 9 sec. Two groups were examined, the first of which consisting of healthy male subjects aged 22-26 years, while the second was comprised of subjects aged 65-84 years on no medication; radiograms were recorded continuously beginning just prior to tilt until 3 min posttilt. The results of spectral analysis showed that elderly subjects did not exhibit the Mayer-like heart rate waves (the 0.07-0.09 Hz oscillations) that were present in the spectra of young subjects immediately after passive upright tilt. The findings are consistent with the concept of a 'dysautonomia of aging'. It is suggested that postural stress testing with spectral analysis of heart rate fluctuations may provide a useful way of assessing physiologic vs chronologic age.

  13. The clinical significance of detection to heart rate deceleration capacity and heart rate variability in patients with chronic heart failure

    Directory of Open Access Journals (Sweden)

    Jiang-rong Zhou

    2015-01-01

    Full Text Available Objective: To study the change of heart rate deceleration capacity ( DC and heart rate variability in patients with chronic heart failure (CHF and its relationship with left ventricular ejection fraction (LVEF. Methods: DC, LVEF, time and frequency domain parameters of HRV were measured in 66 patients with CHF and 34 healthy adults (control group by using 24h Holter recordings and Echocardiography. The standard deviation of normal R-R intervals( SDNN, squares of differences between adjacent NN intervals ( RMSSD,low frequency power( LFn and high frequency power( HFn and the changes of LVEF were compared between  the two groups,the relationship between DC,LVEF and HRV were studied in patients with CHF. Results: The median value of DC in the patients with CHF was significantly lower than that in control group( 3.1 ± 2.4 ms vs 7.2 ± 1.3 ms,P <0.01.Incidence of abnormal DC in the CHF group was 57.5%,which was significantly higher than that in the control group (P <0.01.The HRV index, including SDNN、RMSSD、LFn、HFn, in the CHF group was significantly lower than that in normal control group (P < 0.01. Significant positive correlation between HRV index and LVEF were confirmed (P < 0.01. Conclusions: DC and HRV index are lower in patients with CHF and have a good correlation with the left ventricular ejection fraction.

  14. Heart Rate Variability and Drawing Impairment in Hypoxemic COPD

    Science.gov (United States)

    Incalzi, Raffaele Antonelli; Corsonello, Andrea; Trojano, Luigi; Pedone, Claudio; Acanfora, Domenico; Spada, Aldo; D'Addio, Gianni; Maestri, Roberto; Rengo, Franco; Rengo, Giuseppe

    2009-01-01

    We studied 54 patients with hypoxemic chronic obstructive pulmonary disease (COPD). The Mini Mental State Examination and the Mental Deterioration Battery were used for neuropsychological assessment. Heart rate variability (HRV) was assessed based on 24-h Holter ECG recording. Mann-Whitney test was used to compare HRV parameters of patients…

  15. Monitoring apparatus for monitoring a user's heart rate and/or heart rate variation

    NARCIS (Netherlands)

    2012-01-01

    A monitoring apparatus (4) monitors a user's heart rate and/or heart rate variation. The apparatus includes a capacitor (22) which is positionable on or near a body part of a person, for example a person's limb, for example an arm (3), such that an electrical capacitance of the capacitor (22) is

  16. Heart rate response to a climber’s fall in sport climbing

    OpenAIRE

    Chaloupsky, David

    2015-01-01

    The research deals with response of heart rate to a climber’s simulated fall in a leading position when indoor climbing. Heart rate of climbers was recorded during ascents of an overhanging route in the leading position, to the given point high above the ground, followed by falling into the last protection. The length of the free fall was defined by the place of the last belay anchor, which was at the height of climber’s ankles. The length of the fall was about two meters of free fall plus th...

  17. Short-term association between personal exposure to noise and heart rate variability: The RECORD MultiSensor Study.

    Science.gov (United States)

    El Aarbaoui, Tarik; Méline, Julie; Brondeel, Ruben; Chaix, Basile

    2017-12-01

    Studies revealed long-term associations between noise exposure and cardiovascular health, but the underlying short-term mechanisms remain uncertain. To explore the concomitant and lagged short-term associations between personal exposure to noise and heart rate variability (HRV) in a real life setting in the Île-de-France region. The RECORD MultiSensor Study collected between July 2014 and June 2015 noise and heart rate data for 75 participants, aged 34-74 years, in their living environments for 7 days using a personal dosimeter and electrocardiography (ECG) sensor on the chest. HRV parameters and noise levels were calculated for 5-min windows. Short-term relationships between noise level and log-transformed HRV parameters were assessed using mixed effects models with a random intercept for participants and a temporal autocorrelation structure, adjusted for heart rate, physical activity (accelerometry), and short-term trends. An increase by one dB(A) of A-weighted equivalent sound pressure level (Leq) was associated with a 0.97% concomitant increase of the Standard deviation of normal to normal intervals (SDNN) (95% CI: 0.92, 1.02), of 2.08% of the Low frequency band power (LF) (95% CI: 1.97, 2.18), of 1.30% of the High frequency band power (HF) (95% CI: 1.17, 1.43), and of 1.16% of the LF/HF ratio (95% CI: 1.10, 1.23). The analysis of lagged exposures to noise adjusted for the concomitant exposure illustrates the dynamic of recovery of the autonomic nervous system. Non-linear associations were documented with all HRV parameters with the exception of HF. Piecewise regression revealed that the association was almost 6 times stronger below than above 65 Leq dB(A) for the SDNN and LF/HF ratio. Personal noise exposure was found to be related to a concomitant increase of the overall HRV, with evidence of imbalance of the autonomic nervous system towards sympathetic activity, a pathway to increased cardiovascular morbidity and mortality. Copyright © 2017 Elsevier Ltd

  18. Reduced Dietary Sodium Intake Increases Heart Rate

    DEFF Research Database (Denmark)

    Graudal, Niels A; Hubeck-Graudal, Thorbjørn; Jürgens, Gesche

    2016-01-01

    Reduced dietary sodium intake (sodium reduction) increases heart rate in some studies of animals and humans. As heart rate is independently associated with the development of heart failure and increased risk of premature death a potential increase in heart rate could be a harmful side......-effect of sodium reduction. The purpose of the present meta-analysis was to investigate the effect of sodium reduction on heart rate. Relevant studies were retrieved from an updated pool of 176 randomized controlled trials (RCTs) published in the period 1973-2014. Sixty-three of the RCTs including 72 study...... populations reported data on heart rate. In a meta-analysis of these data sodium reduction increased heart rate with 1.65 beats per minute [95% CI: 1.19, 2.11], p heart rate. This effect was independent of baseline blood pressure. In conclusion sodium reduction...

  19. Relationships between heart rate and age, bodyweight and breed in 10,849 dogs.

    Science.gov (United States)

    Hezzell, M J; Dennis, S G; Humm, K; Agee, L; Boswood, A

    2013-06-01

    To evaluate relationships between heart rate and clinical variables in healthy dogs and dogs examined at a referral hospital. Clinical data were extracted from the electronic patient records of a first opinion group (5000 healthy dogs) and a referral hospital (5849 dogs). Univariable and multi-variable general linear models were used to assess associations between heart rate and clinical characteristics. Separate multi-variable models were constructed for first opinion and referral populations. In healthy dogs, heart rate was negatively associated with bodyweight (PChihuahuas. The mean difference in heart rate between a 5 and 55 kg dog was 10.5 beats per minute. In dogs presenting to a referral hospital, heart rate was negatively associated with bodyweight (P<0.001) and the following breeds; border collie, golden retriever, Labrador retriever, springer spaniel and West Highland white terrier and positively associated with age, admitting service (emergency and critical care, emergency first opinion and cardiology) and the following breeds; Cavalier King Charles spaniel, Staffordshire bull terrier and Yorkshire terrier. Bodyweight, age, breed and disease status all influence heart rate in dogs, although these factors account for a relatively small proportion of the overall variability in heart rate. © 2013 British Small Animal Veterinary Association.

  20. The role of abnormal fetal heart rate in scheduling chorionic villus sampling.

    Science.gov (United States)

    Yagel, S; Anteby, E; Ron, M; Hochner-Celnikier, D; Achiron, R

    1992-09-01

    To assess the value of fetal heart rate (FHR) measurements in predicting spontaneous fetal loss in pregnancies scheduled for chorionic villus sampling (CVS). A prospective descriptive study. Two hospital departments of obstetrics and gynaecology in Israel. 114 women between 9 and 11 weeks gestation scheduled for chorionic villus sampling (CVS). Fetal heart rate was measured by transvaginal Doppler ultrasound and compared with a monogram established from 75 fetuses. Whenever a normal FHR was recorded, CVS was performed immediately. 106 women had a normal FHR and underwent CVS; two of these pregnancies ended in miscarriage. In five pregnancies no fetal heart beats could be identified and fetal death was diagnosed. In three pregnancies an abnormal FHR was recorded and CVS was postponed; all three pregnancies ended in miscarriage within 2 weeks. Determination of FHR correlated with crown-rump length could be useful in predicting spontaneous miscarriage before performing any invasive procedure late in the first trimester.

  1. Effects of social stress on heart rate and heart rate variability in growing pigs

    NARCIS (Netherlands)

    Jong, de I.C.; Sgoifo, A.; Lambooij, E.; Korte, S.M.; Blokhuis, H.J.; Koolhaas, J.M.

    2000-01-01

    The effects of social stress on heart rate, heart rate variability and the occurrence of cardiac arrhythmias were studied in 12 growing pigs. Social stress was induced during a good competition test with a pen mate, and subsequently during a resident-intruder test with an unacquainted pig in which

  2. Effects of social stress on heart rate and heart rate variability in growing pigs

    NARCIS (Netherlands)

    de Jong, IC; Sgoifo, A; Lambooij, E; Korte, SM; Blokhuis, HJ; Koolhaas, JM

    The effects of social stress on heart rate, heart rate variability and the occurrence of cardiac arrhythmias were studied in 12 growing pigs. Social stress was induced during a good competition test with a pen mate, and subsequently during a resident-intruder test with an unacquainted pig in which

  3. Evaluation of Stress Parameters Based on Heart Rate Variability Measurements

    OpenAIRE

    Uysal, Fatma; Tokmakçı, Mahmut

    2018-01-01

    In this study, heart rate variabilitymeasurements and analysis was carried with help of the ECG recordings to showhow autonom nervous system activity changes. So as to evaluate the parametersrelated to stress of the study, the situation of relaxation, Stroop color/wordtest, mental test and auditory stimulus that would stress someone out wereapplied to six volunteer participants in a laboratory environment. Being takentotally seven minutes ECG recording and made analysis in time and frequencyd...

  4. Chronic intermittent hypoxia-hypercapnia blunts heart rate responses and alters neurotransmission to cardiac vagal neurons.

    Science.gov (United States)

    Dyavanapalli, Jhansi; Jameson, Heather; Dergacheva, Olga; Jain, Vivek; Alhusayyen, Mona; Mendelowitz, David

    2014-07-01

    Patients with obstructive sleep apnoea experience chronic intermittent hypoxia-hypercapnia (CIHH) during sleep that elicit sympathetic overactivity and diminished parasympathetic activity to the heart, leading to hypertension and depressed baroreflex sensitivity. The parasympathetic control of heart rate arises from pre-motor cardiac vagal neurons (CVNs) located in nucleus ambiguus (NA) and dorsal motor nucleus of the vagus (DMNX). The mechanisms underlying diminished vagal control of heart rate were investigated by studying the changes in blood pressure, heart rate, and neurotransmission to CVNs evoked by acute hypoxia-hypercapnia (H-H) and CIHH. In vivo telemetry recordings of blood pressure and heart rate were obtained in adult rats during 4 weeks of CIHH exposure. Retrogradely labelled CVNs were identified in an in vitro brainstem slice preparation obtained from adult rats exposed either to air or CIHH for 4 weeks. Postsynaptic inhibitory or excitatory currents were recorded using whole cell voltage clamp techniques. Rats exposed to CIHH had increases in blood pressure, leading to hypertension, and blunted heart rate responses to acute H-H. CIHH induced an increase in GABAergic and glycinergic neurotransmission to CVNs in NA and DMNX, respectively; and a reduction in glutamatergic neurotransmission to CVNs in both nuclei. CIHH blunted the bradycardia evoked by acute H-H and abolished the acute H-H evoked inhibition of GABAergic transmission while enhancing glycinergic neurotransmission to CVNs in NA. These changes with CIHH inhibit CVNs and vagal outflow to the heart, both in acute and chronic exposures to H-H, resulting in diminished levels of cardioprotective parasympathetic activity to the heart as seen in OSA patients. © 2014 The Authors. The Journal of Physiology © 2014 The Physiological Society.

  5. Stress level in wild harbour porpoises (Phocoena phocoena) during satellite tagging measured by respiration, heart rate and cortisol

    DEFF Research Database (Denmark)

    Eskesen, Ida Grønborg; Teilmann, J.; Geertsen, B. M.

    2009-01-01

    During satellite tagging of harbour porpoises (Phocoena phocoena), heart rate, respiration rate and cortisol value were measured to evaluate stress effects during handling and tagging. Respiration rates were obtained using video recordings, heart rates were recorded and serum cortisol levels were...... between cortisol and month of year, sex and body length. As high individual variations occurred in response to tagging of harbour porpoises, it is not possible to give general advice based oil the factors investigated, on how to reduce stress during handling. However, pouring water over the animal...

  6. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    Directory of Open Access Journals (Sweden)

    Peter Van Leeuwen

    Full Text Available It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization.In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance.In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data.The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  7. Aerobic exercise during pregnancy and presence of fetal-maternal heart rate synchronization.

    Science.gov (United States)

    Van Leeuwen, Peter; Gustafson, Kathleen M; Cysarz, Dirk; Geue, Daniel; May, Linda E; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates.

  8. Aerobic Exercise during Pregnancy and Presence of Fetal-Maternal Heart Rate Synchronization

    Science.gov (United States)

    Van Leeuwen, Peter; Gustafson, Kathleen M.; Cysarz, Dirk; Geue, Daniel; May, Linda E.; Grönemeyer, Dietrich

    2014-01-01

    It has been shown that short-term direct interaction between maternal and fetal heart rates may take place and that this interaction is affected by the rate of maternal respiration. The aim of this study was to determine the effect of maternal aerobic exercise during pregnancy on the occurrence of fetal-maternal heart rate synchronization. Methods In 40 pregnant women at the 36th week of gestation, 21 of whom exercised regularly, we acquired 18 min. RR interval time series obtained simultaneously in the mothers and their fetuses from magnetocardiographic recordings. The time series of the two groups were examined with respect to their heart rate variability, the maternal respiratory rate and the presence of synchronization epochs as determined on the basis of synchrograms. Surrogate data were used to assess whether the occurrence of synchronization was due to chance. Results In the original data, we found synchronization occurred less often in pregnancies in which the mothers had exercised regularly. These subjects also displayed higher combined fetal-maternal heart rate variability and lower maternal respiratory rates. Analysis of the surrogate data showed shorter epochs of synchronization and a lack of the phase coordination found between maternal and fetal beat timing in the original data. Conclusion The results suggest that fetal-maternal heart rate coupling is present but generally weak. Maternal exercise has a damping effect on its occurrence, most likely due to an increase in beat-to-beat differences, higher vagal tone and slower breathing rates. PMID:25162592

  9. Neonatal heart rate prediction.

    Science.gov (United States)

    Abdel-Rahman, Yumna; Jeremic, Aleksander; Tan, Kenneth

    2009-01-01

    Technological advances have caused a decrease in the number of infant deaths. Pre-term infants now have a substantially increased chance of survival. One of the mechanisms that is vital to saving the lives of these infants is continuous monitoring and early diagnosis. With continuous monitoring huge amounts of data are collected with so much information embedded in them. By using statistical analysis this information can be extracted and used to aid diagnosis and to understand development. In this study we have a large dataset containing over 180 pre-term infants whose heart rates were recorded over the length of their stay in the Neonatal Intensive Care Unit (NICU). We test two types of models, empirical bayesian and autoregressive moving average. We then attempt to predict future values. The autoregressive moving average model showed better results but required more computation.

  10. Hopfield neural network and optical fiber sensor as intelligent heart rate monitor

    Science.gov (United States)

    Mutter, Kussay Nugamesh

    2018-01-01

    This paper presents a design and fabrication of an intelligent fiber-optic sensor used for examining and monitoring heart rate activity. It is found in the literature that the use of fiber sensors as heart rate sensor is widely studied. However, the use of smart sensors based on Hopfield neural networks is very low. In this work, the sensor is a three fibers without cladding of about 1 cm, fed by laser light of 1550 nm of wavelength. The sensing portions are mounted with a micro sensitive diaphragm to transfer the pulse pressure on the left radial wrist. The influenced light intensity will be detected by a three photodetectors as inputs into the Hopfield neural network algorithm. The latter is a singlelayer auto-associative memory structure with a same input and output layers. The prior training weights are stored in the net memory for the standard recorded normal heart rate signals. The sensors' heads work on the reflection intensity basis. The novelty here is that the sensor uses a pulse pressure and Hopfield neural network in an integrity approach. The results showed a significant output measurements of heart rate and counting with a plausible error rate.

  11. Heart rate variability in normal-weight patients with polycystic ovary syndrome.

    Science.gov (United States)

    Kilit, Celal; Paşalı Kilit, Türkan

    2017-05-01

    Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. We examined the heart rate variability in 60 normal-weight women with PCOS and compared them with that in 60 age-matched healthy women having a similar metabolic profile. Time and frequency domain parameters of heart rate variability were analyzed based on 5-min-long continuous electrocardiography recordings for the following 3 periods: (1) during rest in supine position, (2) during controlled breathing, and (3) during isometric handgrip exercise. Time and frequency domain parameters of heart rate variability for the 3 periods assessed were similar in the two groups. Although modified Ferriman-Gallwey score and serum testosterone and luteinizing hormone levels were significantly higher in women with PCOS, homeostatic model assessment-insulin resistance (HOMA-IR) was not different the between the PCOS and control groups. There were no significant correlations between serum testosterone levels and heart rate variability parameters among the study population. The findings of this study suggest that the reactivity of cardiac sympathovagal balance is not altered in normal-weight women with PCOS having a normal HOMA-IR.

  12. HEART RATE RECOVERY AFTER EXERCISE AND NEURAL REGULATION OF HEART RATE VARIABILITY IN 30-40 YEAR OLD FEMALE MARATHON RUNNERS

    Directory of Open Access Journals (Sweden)

    Toshio Matsuoka

    2005-03-01

    Full Text Available The aim of the present study was to examine the effects of endurance training on heart rate (HR recovery after exercise and cardiac autonomic nervous system (ANS modulation in female marathon runners by comparing with untrained controls. Six female marathon runners (M group aged 32-40 years and eight age-matched untrained females (C group performed a maximum-effort treadmill running exercise. Maximal oxygen uptake (VO2max was measured during the exercise with a gas analyzer connected to subjects through a face mask. Heart rate, blood pressure and blood lactate were measured before and after the exercise. Rating of perceived exertion (RPE to the exercise was obtained immediately after the exercise. Holter ECG was recorded and analyzed with power spectral analysis of heart rate variability (HRV to investigate the cardiac ANS modulation. The M group had significantly higher VO2max, faster HR recovery after exercise, higher Mean RR, SDRR, HF power and lower LF/HF ratio at rest compared with the C group. The M group also presented greater percent decrease of blood pressure after exercise, although their blood pressure after exercise was higher than the C group. It is suggested that endurance training induced significant alterations in cardiac ANS modulation at rest and significant acceleration of HR recovery after exercise in female marathon runners. Faster HR recovery after exercise in the female marathon runners should result from their higher levels of HRV, higher aerobic capacity and exaggerated blood pressure response to exercise compared with untrained controls.

  13. Segmentation of heart sound recordings by a duration-dependent hidden Markov model

    International Nuclear Information System (INIS)

    Schmidt, S E; Graff, C; Toft, E; Struijk, J J; Holst-Hansen, C

    2010-01-01

    Digital stethoscopes offer new opportunities for computerized analysis of heart sounds. Segmentation of heart sound recordings into periods related to the first and second heart sound (S1 and S2) is fundamental in the analysis process. However, segmentation of heart sounds recorded with handheld stethoscopes in clinical environments is often complicated by background noise. A duration-dependent hidden Markov model (DHMM) is proposed for robust segmentation of heart sounds. The DHMM identifies the most likely sequence of physiological heart sounds, based on duration of the events, the amplitude of the signal envelope and a predefined model structure. The DHMM model was developed and tested with heart sounds recorded bedside with a commercially available handheld stethoscope from a population of patients referred for coronary arterioangiography. The DHMM identified 890 S1 and S2 sounds out of 901 which corresponds to 98.8% (CI: 97.8–99.3%) sensitivity in 73 test patients and 13 misplaced sounds out of 903 identified sounds which corresponds to 98.6% (CI: 97.6–99.1%) positive predictivity. These results indicate that the DHMM is an appropriate model of the heart cycle and suitable for segmentation of clinically recorded heart sounds

  14. Influence of different characteristics of sport on heart rate recovery in elite athletes

    Directory of Open Access Journals (Sweden)

    Anđić Radovan

    2016-01-01

    Full Text Available Introduction: One of the benefits of regular physical activity is lower resting heart rate and its faster recovery after maximal exercise test, as a result of a stronger parasympatic (vagal tone. Heart rate recovery is used as reliable parameter for prescription of the training program and also in prognostic purposes as a parameter of risk for developing cardiovascular diseases. Aim: The purpose of this study is to show significant differences in heart rate recovery after maximal exercise test and resting heart rate among different groups of elite athletes. Material and Methods: This study subjected 575 adult (23.1 ± 4.3 years, male athletes divided into four sport groups: skill, power, mixed and endurance. Every subject performed progressive, maximal cardiopulmonary exercise test on a treadmill. Heart rate recovery in first (ΔHRR1 and third (ΔHRR3 minute was calculated as a difference of maximal heart rate and heart rate in the first and the third minute after cessation of exercise, respectively. Results: Compared to skill, power and mixed group (62.9 ± 11.4; 61.5 ± 10.0; 59.9 ± 10.4 min-1 respectively, significantly lower values od resting heart rate are recorded in the endurance group (56.2 ± 10.6 min-1 (p = 0,05. Also, ΔHRR1 was significantly higher in the endurance group (33.5 ±14.3 min-1 compared to skill, power and mixed group (24.3 ± 10.9; 25.5 ± 11.2; 27.8 ± 15.6 min-1 respectively (p = 0,05. Values od ΔHRR3 were significantly higher in power, mixed and endurance groups (74.8 ± 14.3; 79.5 ± 12.7; 79.4 ± 12.6 min-1 respectively compared to skill group (67.3±16.1 min-1 (p = 0,05. Conclusion: Training endurance group of sports has the most contribution to lower resting heart rate and faster recovery of heart rate in the first minute after exercising, due to dominant parasympatic tone.

  15. Variation in heart rate influences the assessment of transient ischemic dilation in myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Leslie, William D; Levin, Daniel P; Demeter, Sandor J

    2007-01-01

    Transient arrhythmias can affect transient ischemic dilation (TID) ratios. This study was initiated to evaluate the frequency and effect of normal heart rate change on TID measures in routine clinical practice. Consecutive patients undergoing stress/rest sestamibi gated myocardial perfusion scintigraphy were studied (N = 407). Heart rate at the time of stress and rest imaging were recorded. TID ratios were analyzed in relation to absolute change in heart rate (stress minus rest) for subjects with normal perfusion and systolic function (Group 1, N = 169) and those with abnormalities in perfusion and/or function (Group 2, N = 238). In Group 1, mean TID ratio was inversely correlated with the change in heart rate (r = -0.47, P < 0.0001). For every increase of 10 BPM in heart rate change, the TID ratio decreased by approximately 0.06 (95% confidence interval 0.04–0.07). In Group 2, multiple linear regression demonstrated that the change in heart rate (beta = -0.25, P < 0.0001) and the summed difference score (beta = 0.36, P < 0.0001) were independent predictors of the TID ratio. Normal variation in heart rate between the stress and rest components of myocardial perfusion scans is common and can influence TID ratios in patients with normal and abnormal cardiac scans

  16. Gender differences of heart rate variability in healthy volunteers

    International Nuclear Information System (INIS)

    Saleem, S.; Majeed, S.M.I.; Khan, M.A.

    2012-01-01

    Objective: To identify the basic values of heart rate variability in Pakistani population and to verify our hypothesis that there are gender differences in cardiovascular autonomic modulation. Methods: The descriptive cross sectional study based on convenience probability sampling was conducted at Armed Forces Institute of Cardiology/National Institute of Heart Diseases (AFIC/NIHD) Pakistan. The duration of the study was from December 2009 to July 2010. It involved 24-hour holter monitoring of 45 healthy individuals using holter electrocardiography (ECG) recorder. Heart rate variability was analysed in time (SDNN, SDANN, SDNNi, rMSSD, pNN50) and frequency domains (power, VLF, LF, and HF). Results: The time domain indices; SDNN (male=140 +- 36 ms vs. females=122 +- 33 ms; p =0.09), SDANN (male=123 +- 34 ms vs. females=111+- 34 ms; P= 0.23), SDNNi (male=64 +-19 ms vs. females=52 +- 14 ms; P= 0.03), and pNN50 (male=14 +- 10 ms vs. females=12 +- 7 ms; P= 0.43) were decreased in female volunteers when compared with males. Comparison of frequency domain indices; Total power (male=4041 +- 3150 ms/sup 2/ vs. females=2750 +- 1439 ms/sup 2/; P= 0.07), VLF (male=291 2675 ms/sup 2/ vs. females=1843 +- 928 ms/sup 2/; P= 0.06), LF (male=788 +- 397 ms/sup 2/ vs. females=556 +- 346 ms/sup 2/; P= 0.04) and HF (male=318 +- 251 ms/sup 2/ vs. females=31 277 ms/sup 2/; P= 0.94) amongst males and females showed attenuated heart rate variability in females. Of all the observed values, SDNNi and LF were found significantly (p <0.05) decreased in women. Conclusion: In healthy population, heart rate variability is low in women than men. It reflects sympathetic dominance in women in our population. (author)

  17. Heart rate turbulence and variability in patients with ventricular arrhythmias

    Directory of Open Access Journals (Sweden)

    Diego Tarricone

    2009-08-01

    Full Text Available Background: To evaluate the changes in autonomic neural control mechanisms before malignant ventricular arrhythmias, we measured heart rate variability (HRV and heart rate turbulence (HRT in patients with ventricular tachycardia or fibrillation (Group I; n=6, non sustained ventricular tachycardia (Group II; n=32, frequent premature ventricular beats (Group III; n=26 and with ICD implantation (Group IV; n=11. Methods: Time domain parameters of HRV and turbulence onset (TO and slope (TS were calculated on 24 hour Holter recordings. Normal values were: SDNN > 70 msec for HRV, TO <0% and TS >2.5 msec/RR-I for HRT. Results: Whereas SDNN was within normal range and similar in all study groups, HRT parameters were significantly different in patients who experienced VT/VF during Holter recording. Abnormal TO and/or TS were present in 100% of Group I patients and only in about 50% of Group II and IV. On the contrary, normal HRT parameters were present in 40-70% of Group II, III and IV patients and none of Group I. Conclusions: These data suggest that HRT analysis is more suitable than HRV to detect those transient alterations in autonomic control mechanisms that are likely to play a major trigger role in the genesis of malignant cardiac arrhythmias. (Heart International 2007; 3: 51-7

  18. Flecainide attenuates rate adaptation of ventricular repolarization in guinea-pig heart

    DEFF Research Database (Denmark)

    Osadchii, Oleg E.

    2016-01-01

    examined flecainide effect on adaptation of the QT interval and ventricular action potential duration (APD) to abrupt reductions of the cardiac cycle length. DESIGN: ECG and ventricular epicardial and endocardial monophasic APD were recorded in isolated, perfused guinea-pig heart preparations upon...... a sustained cardiac acceleration (rapid pacing for 30 s), and following a single perturbation of the cycle length evoked by extrasystolic stimulation. RESULTS: Sustained increase in heart rate was associated with progressive bi-exponential shortening of the QT interval and APD. Flecainide prolonged...

  19. Reduced intrinsic heart rate is associated with reduced arrhythmic susceptibility in guinea-pig heart.

    Science.gov (United States)

    Osadchii, Oleg E

    2014-12-01

    In the clinical setting, patients with slower resting heart rate are less prone to cardiovascular death compared with those with elevated heart rate. However, electrophysiological adaptations associated with reduced cardiac rhythm have not been thoroughly explored. In this study, relationships between intrinsic heart rate and arrhythmic susceptibility were examined by assessments of action potential duration (APD) rate adaptation and inducibility of repolarization alternans in sinoatrial node (SAN)-driven and atrioventricular (AV)-blocked guinea-pig hearts perfused with Langendorff apparatus. Electrocardiograms, epicardial monophasic action potentials, and effective refractory periods (ERP) were assessed in normokalemic and hypokalemic conditions. Slower basal heart rate in AV-blocked hearts was associated with prolonged ventricular repolarization during spontaneous beating, and with attenuated APD shortening at increased cardiac activation rates during dynamic pacing, when compared with SAN-driven hearts. During hypokalemic perfusion, the inducibility of repolarization alternans and tachyarrhythmia by rapid pacing was found to be lower in AV-blocked hearts. This difference was ascribed to prolonged ERP in the setting of reduced basal heart rate, which prevented ventricular capture at critically short pacing intervals required to induce arrhythmia. Reduced basal heart rate is associated with electrophysiological changes that prevent electrical instability upon an abrupt cardiac acceleration.

  20. Onset of decreased heart work is correlated with increased heart rate and shortened QT interval in high-carbohydrate fed overweight rats.

    Science.gov (United States)

    Durak, Aysegul; Olgar, Yusuf; Tuncay, Erkan; Karaomerlioglu, Irem; Kayki Mutlu, Gizem; Arioglu Inan, Ebru; Altan, Vecdi Melih; Turan, Belma

    2017-11-01

    Mechanical activity of the heart is adversely affected in metabolic syndrome (MetS) characterized by increased body mass and marked insulin resistance. Herein, we examined the effects of high carbohydrate intake on cardiac function abnormalities by evaluating in situ heart work, heart rate, and electrocardiograms (ECGs) in rats. MetS was induced in male Wistar rats by adding 32% sucrose to drinking water for 22-24 weeks and was confirmed by insulin resistance, increased body weight, increased blood glucose and serum insulin, and increased systolic and diastolic blood pressures in addition to significant loss of left ventricular integrity and increased connective tissue around myofibrils. Analysis of in situ ECG recordings showed a markedly shortened QT interval and decreased QRS amplitude with increased heart rate. We also observed increased oxidative stress and decreased antioxidant defense characterized by decreases in serum total thiol level and attenuated paraoxonase and arylesterase activities. Our data indicate that increased heart rate and a shortened QT interval concomitant with higher left ventricular developed pressure in response to β-adrenoreceptor stimulation as a result of less cyclic AMP release could be regarded as a natural compensation mechanism in overweight rats with MetS. In addition to the persistent insulin resistance and obesity associated with MetS, one should consider the decreased heart work, increased heart rate, and shortened QT interval associated with high carbohydrate intake, which may have more deleterious effects on the mammalian heart.

  1. Combinatorial effect of nicotine and black tea on heart rate variability: Useful or harmful?

    Science.gov (United States)

    Joukar, S; Sheibani, M

    2017-06-01

    The effect of nicotine on heart rate variability (HRV) is controversial. Autonomic nervous system is the main regulator of heart rhythm, and heart rate variability is an appropriate index to assessment of the effects of the autonomic system on heart. In this study, the combination effect of nicotine and black tea consumption on sympatho-vagal balance and heart rate variability was investigated in rats. Male Wistar rats were randomized into four groups as control, tea (2.5 g/100 cc, daily), nicotine (2 mg/kg/d) and tea plus nicotine groups which treated for 28 days, and in the 29th day, their electrocardiograms (lead II) were recorded. The mean of high-frequency power (HF) in tea, nicotine and tea plus nicotine groups was significantly more than control group (P nicotine and tea + nicotine groups was significantly less than control group (P nicotine and tea + nicotine groups in comparison with control group (P nicotine or their combination with dosages used in this study can increase the heart rate variability and improve the sympatho-vagal balance in rat. © 2017 John Wiley & Sons Ltd.

  2. Impact of space weather on human heart rate during the years 2011-2013

    Science.gov (United States)

    Galata, E.; Ioannidou, S.; Papailiou, M.; Mavromichalaki, H.; Paravolidakis, K.; Kouremeti, M.; Rentifis, L.; Simantirakis, E.; Trachanas, K.

    2017-08-01

    During the last years a possible link between different levels of solar and geomagnetic disturbances and human physiological parameters is suggested by several published studies. In this work the examination of the potential association between heart rate variations and specific space weather activities was performed. A total of 482 individuals treated at Hippocratio General Hospital in Athens, the Cardiology clinics of Nikaia General Hospital in Piraeus and the Heraklion University Hospital in Crete, Greece, were assessed from July 2011 to April 2013. The heart rate of the individuals was recorded by a Holter monitor on a n hourly basis, while the hourly variations of the cosmic ray intensity measured by the Neutron Monitor Station of the Athens University and of the geomagnetic index Dst provided by the Kyoto Observatory were used. The ANalysis Of VAriance (ANOVA) and the Multiple Linear Regression analysis were used for analysis of these data. A statistically significant effect of both cosmic rays and geomagnetic activity on heart rate was observed, which may indicate that changes in space weather could be linked to heart rate variations.

  3. Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?

    Science.gov (United States)

    Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J

    2017-07-01

    For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.

  4. PRES- and orthostatic-induced heart-rate changes as markers of labile hypertension : magnitude and reliability measures.

    OpenAIRE

    Rau, Harald; Furedy, John J.; Elbert, Thomas

    1996-01-01

    Split-half and test-retest reliabilities of heart-rate responses to a baroreceptor manipulation and an orthostatic manoeuver were compared between subjects with either normal or elevated blood-pressure. Ten subjects showing elevated resting blood-pressure and 11 normotensive subjects participated in two experimental sessions, each including heart-rate recordings during baroreceptor manipulation and orthostatic challenge. Carotid baroreceptors were manipulated by applying the baroreceptor-spec...

  5. Reduced heart rate variability in social anxiety disorder: associations with gender and symptom severity.

    Directory of Open Access Journals (Sweden)

    Gail A Alvares

    Full Text Available BACKGROUND: Polyvagal theory emphasizes that autonomic nervous system functioning plays a key role in social behavior and emotion. The theory predicts that psychiatric disorders of social dysfunction are associated with reduced heart rate variability, an index of autonomic control, as well as social inhibition and avoidance. The purpose of this study was to examine whether heart rate variability was reduced in treatment-seeking patients diagnosed with social anxiety disorder, a disorder characterized by social fear and avoidance. METHODS: Social anxiety patients (n = 53 were recruited prior to receiving psychological therapy. Healthy volunteers were recruited through the University of Sydney and the general community and were matched by gender and age (n = 53. Heart rate variability was assessed during a five-minute recording at rest, with participants completing a range of self-report clinical symptom measures. RESULTS: Compared to controls, participants with social anxiety exhibited significant reductions across a number of heart rate variability measures. Reductions in heart rate variability were observed in females with social anxiety, compared to female controls, and in patients taking psychotropic medication compared to non-medicated patients. Finally, within the clinical group, we observed significant associations between reduced heart rate variability and increased social interaction anxiety, psychological distress, and harmful alcohol use. CONCLUSIONS: The results of this study confirm that social anxiety disorder is associated with reduced heart rate variability. Resting state heart rate variability may therefore be considered a marker for social approach-related motivation and capacity for social engagement. Additionally, heart rate variability may provide a useful biomarker to explain underlying difficulties with social approach, impaired stress regulation, and behavioral inhibition, especially in disorders associated with

  6. Heart rate profile during exercise in patients with early repolarization.

    Science.gov (United States)

    Cay, Serkan; Cagirci, Goksel; Atak, Ramazan; Balbay, Yucel; Demir, Ahmet Duran; Aydogdu, Sinan

    2010-09-01

    Both early repolarization and altered heart rate profile are associated with sudden death. In this study, we aimed to demonstrate an association between early repolarization and heart rate profile during exercise. A total of 84 subjects were included in the study. Comparable 44 subjects with early repolarization and 40 subjects with normal electrocardiogram underwent exercise stress testing. Resting heart rate, maximum heart rate, heart rate increment and decrement were analyzed. Both groups were comparable for baseline characteristics including resting heart rate. Maximum heart rate, heart rate increment and heart rate decrement of the subjects in early repolarization group had significantly decreased maximum heart rate, heart rate increment and heart rate decrement compared to control group (all P decrement (multiple-adjusted OR of the risk of presence of early repolarization was 2.98 (95%CI 1.21-7.34) (P = 0.018) and 7.73 (95%CI 2.84-21.03) (P decrement compared to higher levels, respectively. Subjects with early repolarization have altered heart rate profile during exercise compared to control subjects. This can be related to sudden death.

  7. Multidetector-row computed tomography coronary angiography. Optimization of image reconstruction phase according to the heart rate

    International Nuclear Information System (INIS)

    Nagatani, Yukihiro; Takahashi, Masashi; Takazakura, Ryutaro; Nitta, Norihisa; Murata, Kiyoshi; Ushio, Noritoshi; Matsuo, Shinro; Yamamoto, Takashi; Horie, Minoru

    2007-01-01

    The purpose of this study was to optimize the image reconstruction phase of multidetector-row computed tomography (MDCT) coronary angiography according to the heart rate is crucial. Scan data were reconstructed for 10 different phases in 58 sequential patients who under went 8-row cardiac MDCT. The obtained images were scored and compared in terms of motion artifacts and visibility of the vessels, and moreover, electrocardiogram (ECG) record-based evaluations were added for clarification of the temporal relationships among these 10 phases. In the cases with lower heart rates ( 65 beats/mm), they were obtained in the late systolic period. As the heart rate increased, the optimal image reconstruction phase changed from mid diastole to late systole. However, it is recommended to try to decrease the heart rate of patients before data acquisition. (author)

  8. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise

    Directory of Open Access Journals (Sweden)

    Masoumeh Sadeghi

    2016-12-01

    Full Text Available The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5% were diagnosed as MetS. The mean resting heart rate (RHR was not statistically different between the two groups (P=0.078. However, the mean maximum heart (MHR rate was considerably higher in participants with MetS (142.37±14.84 beats per min compared to the non-MetS group (134.62±21.63 beats per min (P<0.001. In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033 and was inversely associated with age (β=-0.469, P<0.001. The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004 with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  9. Assessing Metabolic Syndrome Through Increased Heart Rate During Exercise.

    Science.gov (United States)

    Sadeghi, Masoumeh; Gharipour, Mojgan; Nezafati, Pouya; Shafie, Davood; Aghababaei, Esmaeil; Sarrafzadegan, Nizal

    2016-11-01

    The present study aimed to assess changes in resting and maximum heart rates as primary indicators of cardiac autonomic function in metabolic syndrome (MetS) patients and to determine their value for discriminating MetS from non-MetS. 468 participants were enrolled in this cross-sectional study and assessed according to the updated adult treatment panel III (ATP-III) definition of MetS. Resting and maximum heart rates were recorded following the Bruce protocol during an exercise. A receiver operating characteristic (ROC) curve was used to identify the best cutoff point for discriminating MetS from the non-MetS state. 194 participants (41.5%) were diagnosed as MetS. The mean resting heart rate (RHR) was not statistically different between the two groups (P=0.078). However, the mean maximum heart (MHR) rate was considerably higher in participants with MetS (142.37±14.84 beats per min) compared to the non-MetS group (134.62±21.63 beats per min) (P<0.001). In the MetS group, the MHR was positively correlated with the serum triglyceride level (β=0.185, P=0.033) and was inversely associated with age (β=-0.469, P<0.001). The MHR had a moderate value for discriminating MetS from the non-MetS state (c=0.580, P=0.004) with the optimal cutoff point of 140 beats per min. In MetS patients, the MHR was significantly greater compared to non-MetS subjects and was directly correlated with serum triglyceride levels and inversely with advanced age. Moreover, MHR can be used as a suspicious indicator for identifying MetS.

  10. Genome-wide association studies and resting heart rate

    DEFF Research Database (Denmark)

    Oskari Kilpeläinen, Tuomas

    2016-01-01

    Genome-wide association studies (GWASs) have revolutionized the search for genetic variants regulating resting heart rate. In the last 10 years, GWASs have led to the identification of at least 21 novel heart rate loci. These discoveries have provided valuable insights into the mechanisms...... and pathways that regulate heart rate and link heart rate to cardiovascular morbidity and mortality. GWASs capture majority of genetic variation in a population sample by utilizing high-throughput genotyping chips measuring genotypes for up to several millions of SNPs across the genome in thousands...... of individuals. This allows the identification of the strongest heart rate associated signals at genome-wide level. While GWASs provide robust statistical evidence of the association of a given genetic locus with heart rate, they are only the starting point for detailed follow-up studies to locate the causal...

  11. General anesthesia suppresses normal heart rate variability in humans

    Science.gov (United States)

    Matchett, Gerald; Wood, Philip

    2014-06-01

    The human heart normally exhibits robust beat-to-beat heart rate variability (HRV). The loss of this variability is associated with pathology, including disease states such as congestive heart failure (CHF). The effect of general anesthesia on intrinsic HRV is unknown. In this prospective, observational study we enrolled 100 human subjects having elective major surgical procedures under general anesthesia. We recorded continuous heart rate data via continuous electrocardiogram before, during, and after anesthesia, and we assessed HRV of the R-R intervals. We assessed HRV using several common metrics including Detrended Fluctuation Analysis (DFA), Multifractal Analysis, and Multiscale Entropy Analysis. Each of these analyses was done in each of the four clinical phases for each study subject over the course of 24 h: Before anesthesia, during anesthesia, early recovery, and late recovery. On average, we observed a loss of variability on the aforementioned metrics that appeared to correspond to the state of general anesthesia. Following the conclusion of anesthesia, most study subjects appeared to regain their normal HRV, although this did not occur immediately. The resumption of normal HRV was especially delayed on DFA. Qualitatively, the reduction in HRV under anesthesia appears similar to the reduction in HRV observed in CHF. These observations will need to be validated in future studies, and the broader clinical implications of these observations, if any, are unknown.

  12. Interchangeability of electrocardiography and blood pressure measurement for determining heart rate and heart rate variability in free-moving domestic pigs in various behavioral contexts

    Directory of Open Access Journals (Sweden)

    Annika eKrause

    2015-11-01

    Full Text Available This study assessed the interchangeability between heart rate (HR and heart rate variability (HRV measures derived from a series of interbeat intervals (IBIs recorded via electrocardiogram (ECG and intra-arterial blood pressure (BP in various behavioral contexts. Five minutes of simultaneously recorded IBIs from ECG and BP signals in 11 female domestic pigs during resting, feeding and active behavior were analyzed. Comparisons were made for measures of HR, SDNN (the standard deviation of IBIs and RMSSD (the root mean of the squared distances of subsequent IBIs derived from ECG and BP signals for each behavior category using statistical procedures with different explanatory power (linear regression, intraclass correlation coefficient (ICC, Bland and Altman plots and analysis of variance (ANOVA. Linear regression showed a strong relationship for HR during all behaviors and for HRV during resting. Excellent ICCs (lower 95% CI > 0.75 and narrow limits of agreement (LoA in all behavior categories were found for HR. ICCs for HRV reached the critical lower 95% CI value of 0.75 only during resting. Using Bland and Altman plots, HRV agreement was unacceptable for all of the behavior categories. ANOVA showed significant differences between the methods in terms of HRV. BP systematically overestimated HRV compared with ECG. Our findings reveal that HR data recorded via BP agree well those recorded using ECG independently of the activity of the subject, whereas ECG and BP cannot be used interchangeably in the context of HRV in free-moving domestic pigs.

  13. Effects of slow breathing rate on heart rate variability and arterial baroreflex sensitivity in essential hypertension.

    Science.gov (United States)

    Li, Changjun; Chang, Qinghua; Zhang, Jia; Chai, Wenshu

    2018-05-01

    This study is to investigate the effects of slow breathing on heart rate variability (HRV) and arterial baroreflex sensitivity in essential hypertension.We studied 60 patients with essential hypertension and 60 healthy controls. All subjects underwent controlled breathing at 8 and 16 breaths per minute. Electrocardiogram, respiratory, and blood pressure signals were recorded simultaneously. We studied effects of slow breathing on heart rate, blood pressure and respiratory peak, high-frequency (HF) power, low-frequency (LF) power, and LF/HF ratio of HRV with traditional and corrected spectral analysis. Besides, we tested whether slow breathing was capable of modifying baroreflex sensitivity in hypertensive subjects.Slow breathing, compared with 16 breaths per minute, decreased the heart rate and blood pressure (all P hypertensive subjects. Slow breathing increased baroreflex sensitivity in hypertensive subjects (from 59.48 ± 6.39 to 78.93 ± 5.04 ms/mm Hg, P hypertension. Besides, slow breathing increased baroreflex sensitivity in hypertensive subjects. These demonstrate slow breathing is indeed capable of shifting sympatho-vagal balance toward vagal activities and increasing baroreflex sensitivity, suggesting a safe, therapeutic approach for essential hypertension.

  14. Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis

    Directory of Open Access Journals (Sweden)

    Aleš Procházka

    2016-06-01

    Full Text Available This paper is devoted to a new method of using Microsoft (MS Kinect sensors for non-contact monitoring of breathing and heart rate estimation to detect possible medical and neurological disorders. Video sequences of facial features and thorax movements are recorded by MS Kinect image, depth and infrared sensors to enable their time analysis in selected regions of interest. The proposed methodology includes the use of computational methods and functional transforms for data selection, as well as their denoising, spectral analysis and visualization, in order to determine specific biomedical features. The results that were obtained verify the correspondence between the evaluation of the breathing frequency that was obtained from the image and infrared data of the mouth area and from the thorax movement that was recorded by the depth sensor. Spectral analysis of the time evolution of the mouth area video frames was also used for heart rate estimation. Results estimated from the image and infrared data of the mouth area were compared with those obtained by contact measurements by Garmin sensors (www.garmin.com. The study proves that simple image and depth sensors can be used to efficiently record biomedical multidimensional data with sufficient accuracy to detect selected biomedical features using specific methods of computational intelligence. The achieved accuracy for non-contact detection of breathing rate was 0.26% and the accuracy of heart rate estimation was 1.47% for the infrared sensor. The following results show how video frames with depth data can be used to differentiate different kinds of breathing. The proposed method enables us to obtain and analyse data for diagnostic purposes in the home environment or during physical activities, enabling efficient human–machine interaction.

  15. Classic electrocardiogram-based and mobile technology derived approaches to heart rate variability are not equivalent.

    Science.gov (United States)

    Guzik, Przemyslaw; Piekos, Caroline; Pierog, Olivia; Fenech, Naiman; Krauze, Tomasz; Piskorski, Jaroslaw; Wykretowicz, Andrzej

    2018-05-01

    We compared classic ECG-derived versus a mobile approach to heart rate variability (HRV) measurement. 29 young adult healthy volunteers underwent a simultaneous recording of heart rate using an ECG and a chest heart rate monitor at supine rest, during mental stress and active standing. Mean RR interval, Standard Deviation of Normal-to-Normal (SDNN) of RR intervals, and Root Mean Square of the Successive Differences (RMSSD) between RR intervals were computed in 168 pairs of 5-minute epochs by in-house software on a PC (only sinus beats) and by mobile application "ELITEHRV" on a smartphone (no beat type identification). ECG analysis showed that 33.9% of the recordings contained at least one non-sinus beat or artefact, the mobile app did not report this. The mean RR intervals were significantly longer (p = 0.0378), while SDNN (p = 0.0001) and RMSSD (p = 0.0199) were smaller for the mobile approach. Measures of identical HRV parameters by ECG-based and mobile approaches are not equivalent. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Localised photoplethysmography imaging for heart rate estimation of pre-term infants in the clinic

    Science.gov (United States)

    Chaichulee, Sitthichok; Villarroel, Mauricio; Jorge, João.; Arteta, Carlos; Green, Gabrielle; McCormick, Kenny; Zisserman, Andrew; Tarassenko, Lionel

    2018-02-01

    Non-contact vital-sign estimation allows the monitoring of physiological parameters (such as heart rate, respiratory rate, and peripheral oxygen saturation) without contact electrodes or sensors. Our recent work has demonstrated that a convolutional neural network (CNN) can be used to detect the presence of a patient and segment the patient's skin area for vital-sign estimation, thus enabling the automatic continuous monitoring of vital signs in a hospital environment. In a study approved by the local Research Ethical Committee, we made video recordings of pre-term infants nursed in a Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford, UK. We extended the CNN model to detect the head, torso and diaper of the infants. We extracted multiple photoplethysmographic imaging (PPGi) signals from each body part, analysed their signal quality, and compared them with the PPGi signal derived from the entire skin area. Our results demonstrated the benefits of estimating heart rate combined from multiple regions of interest using data fusion. In the test dataset, we achieved a mean absolute error of 2.4 beats per minute for 80% (31.1 hours) from a total recording time of 38.5 hours for which both reference heart rate and video data were valid.

  17. Heart rate variability and heart rate turbulence in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Özkeçeci, Gülay; Ünlü, Bekir Serdar; Dursun, Hüseyin; Akçi, Önder; Köken, Gülengül; Onrat, Ersel; Avşar, Alaettin

    2016-05-01

    Cardiac autonomic dysfunction may develop in patients with polycystic ovary syndrome (PCOS). Heart rate variability (HRV) and heart rate turbulence (HRT) are used in assessing cardiac autonomic functions. The goal of this study was to compare the cardiac autonomic functions in patients with PCOS and healthy controls. To our knowledge, this is the first study evaluating cardiac autonomic functions in patients with PCOS with respect to both HRV and HRT. Twenty-three patients with PCOS (mean age 22.8±3.9 years) and 25 healthy female volunteers who were matched for age and body mass index (BMI) (mean age 23.5±6.2 years) were enrolled in this as case-control study. Twenty-four hour ambulatory electrocardiogram recordings of all participants were taken using Pathfinder software. The time domain parameters of HRV and HRT, including turbulence onset (TO) and turbulence slope, were calculated. Diagnosis of PCOS was made with physical and laboratory findings of hirsutism or biochemical hyperandrogenism and chronic anovulation. Diabetes mellitus, other hormon disorders or hormon therapy, pregnancy, atrial fibrilation, obesite, chronic diseases, disorders of the autonomic nervous system, a history of drug use affecting the autonomic nervous system were excluded. There were no significant differences in HRV and HRT parameters between the two groups. Cardiovascular risk factors, such as BMI, blood pressure, fasting blood glucose, and lipid parameters, were also similar. Triangular index measure of HRV was negatively correlated with high density lipoprotein cholesterol levels (r=-0.47, p<0.05), while age and BMI were significantly correlated with TO (r=0.31 and 0.47, respectively; p<0.05 for all). Cardiac autonomic functions were not found to be altered in patients with PCOS in comparison with healthy controls. These results may be explained with the absence of concomitant cardiovascular risk factors with the patients being in the early stage of the disease.

  18. Activity and heart rate in semi-domesticated reindeer during adaptation to emergency feeding.

    Science.gov (United States)

    Nilsson, A; Ahman, B; Norberg, H; Redbo, I; Eloranta, E; Olsson, K

    2006-06-15

    Although reindeer are well adapted to limited food resources during winter, semi-domesticated reindeer are regularly fed when snow conditions are bad in order to prevent starvation. Feeding sometimes results in health problems and loss of animals. This study was made to assess if activity pattern in reindeer could be used as a tool for the reindeer herder in early detection of animals that are not adapting to feeding. The frequency of 10 behavioural categories was recorded in five groups of penned, eight-month-old, female semi-domesticated reindeer. Three reindeer per group were fitted with heart rate monitors. Lying was the most frequent behaviour, whilst there were few cases of agonistic behaviour. Heart rate varied during the day, with peaks during feeding and low heart rates in the early morning. Restricted feed intake resulted in more locomotion and seeking but less ruminating compared to feeding ad libitum. This was followed by a generally lower heart rate in reindeer in the restricted groups compared to controls. Subsequent feeding with different combinations of lichens, silage and pellets ad libitum resulted initially in significantly more of the animals lying curled up, compared to controls, combined with increased heart rates. As the experiment continued the general activity pattern, as well as the heart rate, gradually became more similar in all groups. Lying curled was the behavioural indicator most consistently affected by feed deprivation and adaptation to feeding and may thus be a useful indicator to distinguish individual reindeer that are not adjusting to feeding.

  19. Robust detection of heart beats in multimodal records using slope- and peak-sensitive band-pass filters.

    Science.gov (United States)

    Pangerc, Urška; Jager, Franc

    2015-08-01

    In this work, we present the development, architecture and evaluation of a new and robust heart beat detector in multimodal records. The detector uses electrocardiogram (ECG) signals, and/or pulsatile (P) signals, such as: blood pressure, artery blood pressure and pulmonary artery pressure, if present. The base approach behind the architecture of the detector is collecting signal energy (differentiating and low-pass filtering, squaring, integrating). To calculate the detection and noise functions, simple and fast slope- and peak-sensitive band-pass digital filters were designed. By using morphological smoothing, the detection functions were further improved and noise intervals were estimated. The detector looks for possible pacemaker heart rate patterns and repairs the ECG signals and detection functions. Heart beats are detected in each of the ECG and P signals in two steps: a repetitive learning phase and a follow-up detecting phase. The detected heart beat positions from the ECG signals are merged into a single stream of detected ECG heart beat positions. The merged ECG heart beat positions and detected heart beat positions from the P signals are verified for their regularity regarding the expected heart rate. The detected heart beat positions of a P signal with the best match to the merged ECG heart beat positions are selected for mapping into the noise and no-signal intervals of the record. The overall evaluation scores in terms of average sensitivity and positive predictive values obtained on databases that are freely available on the Physionet website were as follows: the MIT-BIH Arrhythmia database (99.91%), the MGH/MF Waveform database (95.14%), the augmented training set of the follow-up phase of the PhysioNet/Computing in Cardiology Challenge 2014 (97.67%), and the Challenge test set (93.64%).

  20. Effect of the Torrance Creative Thinking Test on Heart Rate Signal Features

    Directory of Open Access Journals (Sweden)

    Zakeri S.

    2016-02-01

    Full Text Available Aims: Showing a meta-cognitive aspect, creativity is related to higher mental processes such as thinking, intelligence, imagination, and information process. There are many studies on the physiological bases of creativity. The aim of this study was to investigate the effects of creative thinking on the heart rate signal. Materials & Methods: In this semi-experimental study, 52 medical engineering, electrical, and control students of Sahand University were studied in 2012. The subjects were selected via accessible sampling method. To assess the level of the students’ creative thinking, Torrance Tests of Creative Thinking (B form; figural was used. Before and during creative thinking test, heart signal in the rest position was recorded by 1000Hz sampling frequency. Data was analyzed using Wilcoxon non-parametric test.   Findings: There was an increase in the mean heart power amplitude during creative thinking than the rest position. However, passing time and conducting the last sessions of the creativity test, it showed a reduction. There was an increase in the heart rate in persons with high creativity than those with low creativity. In addition, based on the test scores, there was a higher creativity level in females and three-lingual persons than males and bi-lingual persons, respectively. There was an increase in the heart rate in females than males (p=0.0398. Nevertheless, there was no significant difference between three-lingual and bilingual persons (p>0.05.    Conclusion: Creative thinking results in an increase in the heart rate in persons with high creativity than persons with low creativity. Therefore, the creativity level can be detected via heart signal. 

  1. Peak heart rates at extreme altitudes

    DEFF Research Database (Denmark)

    Lundby, C; Van Hall, Gerrit

    2001-01-01

    We have measured maximal heart rate during a graded maximal bicycle exercise test to exhaustion in five healthy climbers before and during an expedition to Mt. Everest. Maximal heart rates at sea level were 186 (177-204) beats/min(-1) at sea level and 170 (169-182) beats/min(-1) with acute hypoxi...

  2. Heart rate turbulence as a marker of myocardial electrical instability in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    V. A. Makarova

    2014-01-01

    Full Text Available Heart rate turbulence is a myocardial electrical instability marker used to stratify the risk of sudden cardiac death. Fifty children aged 7 to 17 years with hypertrophic cardiomyopathy were examined. The survey program included standard electrocardiography, Doppler echocardiography, and 24-hour Holter ECG monitoring. Heart rate turbulence parameters, such as turbulence onset and turbulence slope, were analyzed. According to turbulence onset greater than zero, heart rate turbulence impairment was identified in 5 of the 24 patients included in the survey. The abnormal turbulence slope values of less than 6 msec/RR were found in 3 patients. Both parameters were abnormal in 1 patient. Heart rate turbulence impairment was significantly more common in children with the non-obstructive form of hypertrophic cardiomyopathy than in those with its obstructive form (χ2=3,05; p=0,08. All the children with abnormal heart rhythm turbulence values had one or more major risk factors for sudden cardiac death, which significantly exceeds their rates in the normal heart rate turbulence groups (χ2=7,11; p=0,007. The patients with abnormal turbulence onset values were more often found to have syncope (χ2=3,2; p=0,02. One such patient was recorded to have unstable ventricular tachycardia (χ2=10,56; p=0,001. Our findings suggest that heart rate turbulence is an additional predictor of the unfavorable course of hypertrophic cardiomyopathy in children. 

  3. Ambulatory heart rate is underestimated when measured by an ambulatory blood pressure device

    NARCIS (Netherlands)

    Vrijkotte, T. G.; de Geus, E. J.

    2001-01-01

    To test the validity of ambulatory heart rate (HR) assessment with a cuff ambulatory blood pressure (ABP) monitor. Cross-instrument comparison of HR measured intermittently by a cuff ABP monitor (SpaceLabs, Redmond, Washington, USA), with HR derived from continuous electrocardiogram (ECG) recordings

  4. The effect of relaxing music on heart rate and heart rate variability during ECG GATED-myocardial perfusion scintigraphy.

    Science.gov (United States)

    Tan, Yusuf Ziya; Ozdemir, Semra; Temiz, Ahmet; Celik, Fatmanur

    2015-05-01

    The positive changes in human behavior caused by relaxing music demonstrate the psychological effect of music on human body. A meta-analytical study has shown that relaxing music affects blood pressure and heart rate in coronary heart patients and cancer patients. The aim of our study is to research whether there is a significant effect on heart rate and heart rate variability due to listening to relaxing music during ECG GATED MPS imaging under gamma camera. The music group (n = 50 patients) could choose from 15 different musical types including folk music (no lyric). The other 50 patients were placed in a "no music group" and did not get headphones or any music. There was a statistically significant reduction in the heart rate of patients in the music group compared to those in the control group. Relaxing music provides great benefits to both patient and clinician. There is close relationship between relaxing music and health procedure, can use every area of the health noninvasiv, safe, cheap and is a method don't have side effect. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Heart rate reveals torpor at high body temperatures in lowland tropical free-tailed bats.

    Science.gov (United States)

    O'Mara, M Teague; Rikker, Sebastian; Wikelski, Martin; Ter Maat, Andries; Pollock, Henry S; Dechmann, Dina K N

    2017-12-01

    Reduction in metabolic rate and body temperature is a common strategy for small endotherms to save energy. The daily reduction in metabolic rate and heterothermy, or torpor, is particularly pronounced in regions with a large variation in daily ambient temperature. This applies most strongly in temperate bat species (order Chiroptera), but it is less clear how tropical bats save energy if ambient temperatures remain high. However, many subtropical and tropical species use some daily heterothermy on cool days. We recorded the heart rate and the body temperature of free-ranging Pallas' mastiff bats ( Molossus molossus ) in Gamboa, Panamá, and showed that these individuals have low field metabolic rates across a wide range of body temperatures that conform to high ambient temperature. Importantly, low metabolic rates in controlled respirometry trials were best predicted by heart rate, and not body temperature . Molossus molossus enter torpor-like states characterized by low metabolic rate and heart rates at body temperatures of 32°C, and thermoconform across a range of temperatures. Flexible metabolic strategies may be far more common in tropical endotherms than currently known.

  6. Measuring heart rate with optical sensor

    NARCIS (Netherlands)

    Barachi, M. (Mitra)

    2014-01-01

    The problem addressed in this report is to verify the possibility of using an optical sensor in the SaxShirt in order to extract the heart rate. There are specifically three questions that we try to address. 1) How is it possible to extract heart rate (BPM) from the optical sensor? 2) Is it

  7. Heart Rate Variability as a Measure of Airport Ramp-Traffic Controllers Workload

    Science.gov (United States)

    Hayashi, Miwa; Dulchinos, Victoria Lee

    2016-01-01

    Heart Rate Variability (HRV) has been reported to reflect the person's cognitive and emotional stress levels, and may offer an objective measure of human-operator's workload levels, which are recorded continuously and unobtrusively to the task performance. The present paper compares the HRV data collected during a human-in-the-loop simulation of airport ramp-traffic control operations with the controller participants' own verbal self-reporting ratings of their workload.

  8. Study Heart Rate by Tools from Complex Networks

    International Nuclear Information System (INIS)

    Makowiec, D.; Wdowczyk-Szulc, J.; Zarczynska-Buchowiecka, M.; Gruchala, M.; Rynkiewicz, A.

    2011-01-01

    Heart rate measured as beat-to-beat time intervals varies in time. It is believed that time intervals between subsequent normal heart contractions carry information about the regulatory system of the heart. How to quantify such signals is not clear and because of that heart rate variability is still apart from the clinic routine. In the following, we propose a method for representing a heart rate signal as a directed network. Then we study the signal properties by complex network tools. The signals to study were collected from patients recovering after the heart transplantation. The aim is to classify the progress of adapting of the new heart - graft. Moreover, it is expected that the method allows for visual classification. Our investigations are preliminary, however the obtained results are promising. (authors)

  9. National trends in heart failure hospitalization rates in Slovenia 2004-2012.

    Science.gov (United States)

    Omersa, Daniel; Farkas, Jerneja; Erzen, Ivan; Lainscak, Mitja

    2016-11-01

    Heart failure (HF) hospitalization rates are decreasing in western Europe, but little is known about trends in central and east European countries. We analysed the Slovenian national hospitalization database to determine the burden of HF hospitalization. The Slovenian National Hospital Discharge Registry was searched for HF hospitalizations between 2004 and 2012 in patients aged ≥20 years. A total of 55 531 main HF hospitalizations (43 636 first HF hospitalizations) in 34 406 patients (median age 78 years, 55% female) were recorded. The most common co-morbidities were arterial hypertension (54.3%), atrial fibrillation (40.6%), diabetes mellitus (24.5%), and ischaemic heart disease (21.9%). The number of age-standardized main and first HF hospitalizations per 100 000 population decreased from 249 to 232 (7.1%, P = 0.002) and from 467 to 435 (6.8%, P = 0.074), respectively. Crude main and first HF hospitalization rates increased from 249 to 298 (19.8%, P Slovenia, standardized HF hospitalization rates have decreased but the crude HF hospitalization burden has increased. Readmissions were associated with established cardiovascular risk factors. © 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.

  10. Metaiodobenzylguanidine and heart rate variability in heart failure

    International Nuclear Information System (INIS)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-01-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac 123 I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  11. Metaiodobenzylguanidine and heart rate variability in heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Kurata, Chinori; Shouda, Sakae; Mikami, Tadashi; Uehara, Akihiko; Ishikawa, Keiko [Hamamatsu Univ., Shizuoka (Japan). School of Medicine; Tawarahara, Kei; Nakano, Tomoyasu; Matoh, Fumitaka; Takeuchi, Kazuhiko

    1998-10-01

    It is assumed that the low-frequency power (LF) of heart rate variability (HRV) increases with progress of congestive heart failure (CHF), therefore positively correlating with cardiac {sup 123}I-metaiodobenzylguanidine (MIBG) washout. It is demonstrated here that HRV, including normalized LF, correlated inversely with MIBG washout and positively with the ratio of heart-to-mediastinum MIBG activity in controls and CHF patients, whereas these correlations were not observed within CHF patients. Thus MIBG washout may increase and HRV including normalized LF may decrease with CHF, although the HRV and MIBG measures may not similarly change in proportion to the severity of the cardiac autonomic dysfunction in CHF. (author)

  12. The relationship between phase and heart rate

    International Nuclear Information System (INIS)

    Underwood, S.R.; Walton, S.; Brown, N.J.G.; Laming, P.J.; Ell, P.J.; Emanuel, R.W.; Swanton, R.H.

    1984-01-01

    The Fourier phase image is used in rest and stress radionuclide angiocardiography to assess the timing of ventricular wall motion in a regional fashion, and areas of high phase are taken to reprensent areas of delayed contraction. However, phase increases with heart rate and this can make interpretation difficult. This study investigates the relationship between phase and heart rate. A heterogenous group of 43 subjects was studied by ECG-gated equilibrium radionuclide angiocardiography, all of the subjects having normal extent of left ventricular wall motion as judged by normal ejection fraction and normal amplitude image. Mean left ventricular phase correlated well with mean time of end systole (r=0.92), but there was no correlation with time of end diastole.Thus phase reflects the time of end systole as a proportion of cycle length and should be linearly related to heart rate provided the duration of systole is unchanged. In 28 normal subjects mean left ventricular phase correlated linearly with resting rate (r=0.91), and when exercised the relationship was maintained up to 90 beats per minute. Above this rate the increases were less marked as the duration of systole shortened. The same was true in 4 subjects paced at different rates. Mean resting heart rate in the normal subjects was 70 beats per minute and correcting phase linearly to rate 70 did not change mean left ventricular phase but did decrease the standard deviation from 18 degree to 12 degree. It is concluded that correcting phase for heart rate below 90 beats per minute will increase the sensitivity of the phase image to abnormalities of the timing of ventricular contraction. This correction should be appropriate in resting, isometric exercise, and cold pressor studies but because of the higher heart rates involved will not be appropriate for bicycle exercise. (Author)

  13. Classification of Fetal Heart Rate Tracings Based on Wavelet-Transform & Self-Organizing Map Neural Networks

    National Research Council Canada - National Science Library

    Vasios, G

    2001-01-01

    .... We demonstrate that it is possible to distinguish between healthy subjects and acidemic fetuses by way of wavelet transform analysis of the fetal heart rate recordings and fetal pulse oximetry (FSpO2...

  14. Autonomic dysfunction in HIV patients on antiretroviral therapy: studies of heart rate variability

    DEFF Research Database (Denmark)

    Lebech, Anne-Mette; Kristoffersen, Ulrik Sloth; Mehlsen, Jesper

    2007-01-01

    of healthy volunteers (n = 12) were included. All were non-smokers, non-diabetic and had never received medication for dyslipidaemia or hypertension. Following a 10 min resting period a 5 min ECG recording was performed. Heart rate variability (HRV) analysis was performed in accordance with current...

  15. Heart rate awareness in patients with chronic stable heart failure. A multi-center observational study.

    LENUS (Irish Health Repository)

    Moran, D

    2014-08-23

    We assessed adherence to European Society of Cardiology heart rate guidelines (i.e. heart rates less than 70bpm) in patients with chronic stable heart failure. We also investigated the percent of patients on target doses of rate controlling drugs.

  16. An exploration of heart rate response to differing music rhythm and tempos.

    Science.gov (United States)

    da Silva, Ariany G; Guida, Heraldo L; Antônio, Ana Márcia Dos S; Marcomini, Renata S; Fontes, Anne M G G; Carlos de Abreu, Luiz; Roque, Adriano L; Silva, Sidney B; Raimundo, Rodrigo D; Ferreira, Celso; Valenti, Vitor E

    2014-05-01

    The aim of this study was to investigate acute cardiac response and heart rate variability (HRV) when listening to differing forms of music. Eleven healthy men aged between 18 and 25 years old were included in the study. HRV was recorded at rest for ten minutes with no music, then were asked to listen to classical baroque or heavy metal music for a period of 20 min. It was noted that heart rate variability did not affect HRV indices for time and frequency. In conclusion, music with different tempos does not influence cardiac autonomic regulation in men. However more studies are suggested to explore this topic in greater detail. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  17. Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study.

    Science.gov (United States)

    Kroll, Ryan R; Boyd, J Gordon; Maslove, David M

    2016-09-20

    As the sensing capabilities of wearable devices improve, there is increasing interest in their application in medical settings. Capabilities such as heart rate monitoring may be useful in hospitalized patients as a means of enhancing routine monitoring or as part of an early warning system to detect clinical deterioration. To evaluate the accuracy of heart rate monitoring by a personal fitness tracker (PFT) among hospital inpatients. We conducted a prospective observational study of 50 stable patients in the intensive care unit who each completed 24 hours of heart rate monitoring using a wrist-worn PFT. Accuracy of heart rate recordings was compared with gold standard measurements derived from continuous electrocardiographic (cECG) monitoring. The accuracy of heart rates measured by pulse oximetry (Spo2.R) was also measured as a positive control. On a per-patient basis, PFT-derived heart rate values were slightly lower than those derived from cECG monitoring (average bias of -1.14 beats per minute [bpm], with limits of agreement of 24 bpm). By comparison, Spo2.R recordings produced more accurate values (average bias of +0.15 bpm, limits of agreement of 13 bpm, P<.001 as compared with PFT). Personal fitness tracker device performance was significantly better in patients in sinus rhythm than in those who were not (average bias -0.99 bpm vs -5.02 bpm, P=.02). Personal fitness tracker-derived heart rates were slightly lower than those derived from cECG monitoring in real-world testing and not as accurate as Spo2.R-derived heart rates. Performance was worse among patients who were not in sinus rhythm. Further clinical evaluation is indicated to see if PFTs can augment early warning systems in hospitals. ClinicalTrials.gov NCT02527408; https://clinicaltrials.gov/ct2/show/NCT02527408 (Archived by WebCite at  http://www.webcitation.org/6kOFez3on).

  18. The mitochondrial uniporter controls fight or flight heart rate increases.

    Science.gov (United States)

    Wu, Yuejin; Rasmussen, Tyler P; Koval, Olha M; Joiner, Mei-Ling A; Hall, Duane D; Chen, Biyi; Luczak, Elizabeth D; Wang, Qiongling; Rokita, Adam G; Wehrens, Xander H T; Song, Long-Sheng; Anderson, Mark E

    2015-01-20

    Heart rate increases are a fundamental adaptation to physiological stress, while inappropriate heart rate increases are resistant to current therapies. However, the metabolic mechanisms driving heart rate acceleration in cardiac pacemaker cells remain incompletely understood. The mitochondrial calcium uniporter (MCU) facilitates calcium entry into the mitochondrial matrix to stimulate metabolism. We developed mice with myocardial MCU inhibition by transgenic expression of a dominant-negative (DN) MCU. Here, we show that DN-MCU mice had normal resting heart rates but were incapable of physiological fight or flight heart rate acceleration. We found that MCU function was essential for rapidly increasing mitochondrial calcium in pacemaker cells and that MCU-enhanced oxidative phoshorylation was required to accelerate reloading of an intracellular calcium compartment before each heartbeat. Our findings show that MCU is necessary for complete physiological heart rate acceleration and suggest that MCU inhibition could reduce inappropriate heart rate increases without affecting resting heart rate.

  19. Heart rate and flow velocity variability as determined from umbilical Doppler velocimetry at 10-20 weeks of gestation.

    Science.gov (United States)

    Ursem, N T; Struijk, P C; Hop, W C; Clark, E B; Keller, B B; Wladimiroff, J W

    1998-11-01

    1. The aim of this study was to define from umbilical artery flow velocity waveforms absolute peak systolic and time-averaged velocity, fetal heart rate, fetal heart rate variability and flow velocity variability, and the relation between fetal heart rate and velocity variables in early pregnancy.2.A total of 108 women presenting with a normal pregnancy from 10 to 20 weeks of gestation consented to participate in a cross-sectional study design. Doppler ultrasound recordings were made from the free-floating loop of the umbilical cord.3. Umbilical artery peak systolic and time-averaged velocity increased at 10-20 weeks, whereas fetal heart rate decreased at 10-15 weeks of gestation and plateaued thereafter. Umbilical artery peak systolic velocity variability and fetal heart rate variability increased at 10-20 and 15-20 weeks respectively.4. The inverse relationship between umbilical artery flow velocity and fetal heart rate at 10-15 weeks of gestation suggests that the Frank-Starling mechanism regulates cardiovascular control as early as the late first and early second trimesters of pregnancy. A different underlying mechanism is suggested for the observed variability profiles in heart rate and umbilical artery peak systolic velocity. It is speculated that heart rate variability is mediated by maturation of the parasympathetic nervous system, whereas peak systolic velocity variability reflects the activation of a haemodynamic feedback mechanism.

  20. Interference suppression for EEG recording during open heart surgery

    NARCIS (Netherlands)

    Weide, H. van der; Pronk, R.A.F.

    A device for recording the EEG during open heart surgery is described. It differs from most standard equipment in two ways. First, the input circuit is completely floating from earth and will withstand 500 V DC. Second, radiofrequency (RF)_shielding and filtering permits continuous recording of the

  1. Heart Rate Variability Is Associated with Exercise Capacity in Patients with Cardiac Syndrome X.

    Directory of Open Access Journals (Sweden)

    Dai-Yin Lu

    Full Text Available Heart rate variability (HRV reflects the healthiness of autonomic nervous system, which is associated with exercise capacity. We therefore investigated whether HRV could predict the exercise capacity in the adults with cardiac syndrome X (CSX. A total of 238 subjects (57±12 years, 67.8% men, who were diagnosed as CSX by the positive exercise stress test and nearly normal coronary angiogram were enrolled. Power spectrum from the 24-hour recording of heart rate was analyzed in frequency domain using total power (TP and spectral components of the very low frequency (VLF, low frequency (LF and high frequency (HF ranges. Among the study population, 129 subjects with impaired exercise capacity during the treadmill test had significantly lower HRV indices than those with preserved exercise capacity (≥90% of the age predicted maximal heart rate. After accounting for age, sex, and baseline SBP and heart rate, VLF (odds ratio per 1SD and 95% CI: 2.02, 1.19-3.42, LF (1.67, 1.10-2.55, and TP (1.82, 1.17-2.83 remained significantly associated with preserved exercise capacity. In addition, increased HRV indices were also associated with increased exercise duration, rate-pressure product, and heart rate recovery, independent of age, body mass index, and baseline SBP and heart rate. In subgroup analysis, HRV indices demonstrated similar predictive values related to exercise capacity across various subpopulations, especially in the young. In patients with CSX, HRV was independently associated with exercise capacity, especially in young subjects. The healthiness of autonomic nervous system may have a role in modulating the exercise capacity in patients with CSX.

  2. Arduino-based noise robust online heart-rate detection.

    Science.gov (United States)

    Das, Sangita; Pal, Saurabh; Mitra, Madhuchhanda

    2017-04-01

    This paper introduces a noise robust real time heart rate detection system from electrocardiogram (ECG) data. An online data acquisition system is developed to collect ECG signals from human subjects. Heart rate is detected using window-based autocorrelation peak localisation technique. A low-cost Arduino UNO board is used to implement the complete automated process. The performance of the system is compared with PC-based heart rate detection technique. Accuracy of the system is validated through simulated noisy ECG data with various levels of signal to noise ratio (SNR). The mean percentage error of detected heart rate is found to be 0.72% for the noisy database with five different noise levels.

  3. Noise detection during heart sound recording using periodicity signatures

    International Nuclear Information System (INIS)

    Kumar, D; Carvalho, P; Paiva, R P; Henriques, J; Antunes, M

    2011-01-01

    Heart sound is a valuable biosignal for diagnosis of a large set of cardiac diseases. Ambient and physiological noise interference is one of the most usual and highly probable incidents during heart sound acquisition. It tends to change the morphological characteristics of heart sound that may carry important information for heart disease diagnosis. In this paper, we propose a new method applicable in real time to detect ambient and internal body noises manifested in heart sound during acquisition. The algorithm is developed on the basis of the periodic nature of heart sounds and physiologically inspired criteria. A small segment of uncontaminated heart sound exhibiting periodicity in time as well as in the time-frequency domain is first detected and applied as a reference signal in discriminating noise from the sound. The proposed technique has been tested with a database of heart sounds collected from 71 subjects with several types of heart disease inducing several noises during recording. The achieved average sensitivity and specificity are 95.88% and 97.56%, respectively

  4. Heart rate and blood pressure variations after transvascular patent ductus arteriosus occlusion in dogs.

    Science.gov (United States)

    De Monte, Valentina; Staffieri, Francesco; Caivano, Domenico; Nannarone, Sara; Birettoni, Francesco; Porciello, Francesco; Di Meo, Antonio; Bufalari, Antonello

    2017-08-01

    The objective of the study was to retrospectively analyse the cardiovascular effects that occurs following the transvascular occlusion of patent ductus arteriosus in dogs. Sixteen anaesthesia records were included. Variables were recorded at the time of placing the arterial introducer, occlusion of the ductus, and from 5 to 60min thereafter, including, among the other, heart rate, systolic, diastolic and mean arterial blood pressure. The maximal percentage variation of the aforementioned physiological parameters within 60min of occlusion, compared with the values recorded at the introducer placing, was calculated. The time at which maximal variation occurred was also computed. Correlations between maximal percentage variation of physiological parameters and the diameter of the ductus and systolic and diastolic flow velocity through it were evaluated with linear regression analysis. Heart rate decreased after occlusion of the ductus with a mean maximal percentage variation of 41.0±14.8% after 21.2±13.7min. Mean and diastolic arterial blood pressure increased after occlusion with a mean maximal percentage variation of 30.6±18.1 and 55.4±27.1% after 19.6±12.1 and 15.7±10.8min, respectively. Mean arterial blood pressure variation had a significant and moderate inverse correlation with diastolic and systolic flow velocity through the ductus. Transvascular patent ductus arteriosus occlusion in anaesthetised dogs causes a significant reduction in heart rate and an increase in diastolic and mean blood arterial pressure within 20min of closure of the ductus. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. EFFECT OF FUROSEMIDE AND TORASEMIDE ON HEART RATE VARIABILITY AND VENTRICULAR RHYTHM DISORDERS IN PATIENTS WITH CHRONIC HEART FAILURE COMPLICATING ISCHEMIC HEART DISEASE: COMPARATIVE NONRANDOMIZED STUDY

    Directory of Open Access Journals (Sweden)

    H. H. Shugushev

    2010-01-01

    Full Text Available Aim. To study effect of diuretic therapy with furosemide and torasemide on heart rate variability (HRV and frequency of ventriclar rhythm disorders in patients with chronic heart failure (CHF complicating ischemic heart disease (IHD.Material and methods. Patients (n=107 with CHF III-IV functional class (NYHA complicating IHD were examined. The first group of patients received furosemide, 20-60 mg QD (n=52, the second group received torasemide, 5-20 mg QD (n=55. Analysis of heart rhythm disorders and the basic HRV indicators was performed by ECG 10-minute recordings initially and after 10 days of therapy.Results. Decrease in time and spectral HRV parameters and increase in daily number of ventricular extrasystoles was found in furosemide treated patients. Improvement of HRV parameters and reduction of daily number of ventricular rhythm disorders was found torasemide treated patients.Conclusion. Torasemide therapy improves an autonomic regulation of heart rhythm and leads to the reduction of ventricular heart rhythm disorders in patients with CHF complicating IHD.

  6. Heart rate variability interventions for concussion and rehabilitation

    OpenAIRE

    Conder, Robert L.; Conder, Alanna A.

    2014-01-01

    The study of Heart Rate Variability (HRV) has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain). It is well-established that lack of heart rate variability implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal heart rate variability has been associated ...

  7. Musical Auditory Stimulation Influences Heart Rate Autonomic Responses to Endodontic Treatment

    Directory of Open Access Journals (Sweden)

    Milana Drumond Ramos Santana

    2017-01-01

    Full Text Available We aimed to evaluate the acute effect of musical auditory stimulation on heart rate autonomic regulation during endodontic treatment. The study included 50 subjects from either gender between 18 and 40 years old, diagnosed with irreversible pulpitis or pulp necrosis of the upper front teeth and endodontic treatment indication. HRV was recorded 10 minutes before (T1, during (T2, and immediately (T3 and T4 after endodontic treatment. The volunteers were randomly divided into two equal groups: exposed to music (during T2, T3, and T4 or not. We found no difference regarding salivary cortisol and anxiety score. In the group with musical stimulation heart rate decreased in T3 compared to T1 and mean RR interval increased in T2 and T3 compared to T1. SDNN and TINN indices decreased in T3 compared to T4, the RMSSD and SD1 increased in T4 compared to T1, the SD2 increased compared to T3, and LF (low frequency band increased in T4 compared to T1 and T3. In the control group, only RMSSD and SD1 increased in T3 compared to T1. Musical auditory stimulation enhanced heart rate autonomic modulation during endodontic treatment.

  8. Heart Rate Monitoring in Team Sports—A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription

    Directory of Open Access Journals (Sweden)

    Christoph Schneider

    2018-05-01

    Full Text Available A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3–5 min submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution combined with multivariate analysis, which includes markers of (perceived wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using

  9. Heart Rate Monitoring in Team Sports-A Conceptual Framework for Contextualizing Heart Rate Measures for Training and Recovery Prescription.

    Science.gov (United States)

    Schneider, Christoph; Hanakam, Florian; Wiewelhove, Thimo; Döweling, Alexander; Kellmann, Michael; Meyer, Tim; Pfeiffer, Mark; Ferrauti, Alexander

    2018-01-01

    A comprehensive monitoring of fitness, fatigue, and performance is crucial for understanding an athlete's individual responses to training to optimize the scheduling of training and recovery strategies. Resting and exercise-related heart rate measures have received growing interest in recent decades and are considered potentially useful within multivariate response monitoring, as they provide non-invasive and time-efficient insights into the status of the autonomic nervous system (ANS) and aerobic fitness. In team sports, the practical implementation of athlete monitoring systems poses a particular challenge due to the complex and multidimensional structure of game demands and player and team performance, as well as logistic reasons, such as the typically large number of players and busy training and competition schedules. In this regard, exercise-related heart rate measures are likely the most applicable markers, as they can be routinely assessed during warm-ups using short (3-5 min) submaximal exercise protocols for an entire squad with common chest strap-based team monitoring devices. However, a comprehensive and meaningful monitoring of the training process requires the accurate separation of various types of responses, such as strain, recovery, and adaptation, which may all affect heart rate measures. Therefore, additional information on the training context (such as the training phase, training load, and intensity distribution) combined with multivariate analysis, which includes markers of (perceived) wellness and fatigue, should be considered when interpreting changes in heart rate indices. The aim of this article is to outline current limitations of heart rate monitoring, discuss methodological considerations of univariate and multivariate approaches, illustrate the influence of different analytical concepts on assessing meaningful changes in heart rate responses, and provide case examples for contextualizing heart rate measures using simple heuristics. To

  10. Effect of Heart Rate Variability Biofeedback on Sport Performance, a Systematic Review.

    Science.gov (United States)

    Jiménez Morgan, Sergio; Molina Mora, José Arturo

    2017-09-01

    Aim is to determine if the training with heart rate variability biofeedback allows to improve performance in athletes of different disciplines. Methods such as database search on Web of Science, SpringerLink, EBSCO Academic Search Complete, SPORTDiscus, Pubmed/Medline, and PROQUEST Academic Research Library, as well as manual reference registration. The eligibility criteria were: (a) published scientific articles; (b) experimental studies, quasi-experimental, or case reports; (c) use of HRV BFB as main treatment; (d) sport performance as dependent variable; (e) studies published until October 2016; (f) studies published in English, Spanish, French or Portuguese. The guidelines of the PRISMA statement were followed. Out of the 451 records found, seven items were included. All studies had a small sample size (range from 1 to 30 participants). In 85.71% of the studies (n = 6) the athletes enhanced psychophysiological variables that allowed them to improve their sport performance thanks to training with heart rate variability biofeedback. Despite the limited amount of experimental studies in the field to date, the findings suggest that heart rate variability biofeedback is an effective, safe, and easy-to-learn and apply method for both athletes and coaches in order to improve sport performance.

  11. Heart rate measurement based on face video sequence

    Science.gov (United States)

    Xu, Fang; Zhou, Qin-Wu; Wu, Peng; Chen, Xing; Yang, Xiaofeng; Yan, Hong-jian

    2015-03-01

    This paper proposes a new non-contact heart rate measurement method based on photoplethysmography (PPG) theory. With this method we can measure heart rate remotely with a camera and ambient light. We collected video sequences of subjects, and detected remote PPG signals through video sequences. Remote PPG signals were analyzed with two methods, Blind Source Separation Technology (BSST) and Cross Spectral Power Technology (CSPT). BSST is a commonly used method, and CSPT is used for the first time in the study of remote PPG signals in this paper. Both of the methods can acquire heart rate, but compared with BSST, CSPT has clearer physical meaning, and the computational complexity of CSPT is lower than that of BSST. Our work shows that heart rates detected by CSPT method have good consistency with the heart rates measured by a finger clip oximeter. With good accuracy and low computational complexity, the CSPT method has a good prospect for the application in the field of home medical devices and mobile health devices.

  12. Power spectral analysis of heart rate in hyperthyroidism.

    Science.gov (United States)

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P activity and, thus, a relative hypersympathetic tone.

  13. Heart rate response to hypoxic exercise

    DEFF Research Database (Denmark)

    Lundby, C; Møller, P; Kanstrup, I L

    2001-01-01

    progressively decreased the maximal heart rate from day 1 and onwards; also, hypoxia by itself increased plasma noradrenaline levels after maximal exercise. Domperidone further increased maximal noradrenaline concentrations, but had no effect on maximal heart rate. On each study day at altitude, oxygen......This study examined the effects of dopamine D(2)-receptor blockade on the early decrease in maximal heart rate at high altitude (4559 m). We also attempted to clarify the time-dependent component of this reduction and the extent to which it is reversed by oxygen breathing. Twelve subjects performed...... two consecutive maximal exercise tests, without and with oxygen supplementation respectively, at sea level and after 1, 3 and 5 days at altitude. On each study day, domperidone (30 mg; n=6) or no medication (n=6) was given 1 h before the first exercise session. Compared with sea level, hypoxia...

  14. Increasing T-type calcium channel activity by β-adrenergic stimulation contributes to β-adrenergic regulation of heart rates.

    Science.gov (United States)

    Li, Yingxin; Zhang, Xiaoxiao; Zhang, Chen; Zhang, Xiaoying; Li, Ying; Qi, Zhao; Szeto, Christopher; Tang, Mingxin; Peng, Yizhi; Molkentin, Jeffery D; Houser, Steven R; Xie, Mingxing; Chen, Xiongwen

    2018-04-01

    Cav3.1 T-type Ca 2+ channel current (I Ca-T ) contributes to heart rate genesis but is not known to contribute to heart rate regulation by the sympathetic/β-adrenergic system (SAS). We show that the loss of Cav3.1 makes the beating rates of the heart in vivo and perfused hearts ex vivo, as well as sinoatrial node cells, less sensitive to β-adrenergic stimulation; it also renders less conduction acceleration through the atrioventricular node by β-adrenergic stimulation. Increasing Cav3.1 in cardiomyocytes has the opposite effects. I Ca-T in sinoatrial nodal cells can be upregulated by β-adrenergic stimulation. The results of the present study add a new contribution to heart rate regulation by the SAS system and provide potential new mechanisms for the dysregulation of heart rate and conduction by the SAS in the heart. T-type Ca 2+ channel can be a target for heart disease treatments that aim to slow down the heart rate ABSTRACT: Cav3.1 (α 1G ) T-type Ca 2+ channel (TTCC) is expressed in mouse sinoatrial node cells (SANCs) and atrioventricular (AV) nodal cells and contributes to heart rate (HR) genesis and AV conduction. However, its role in HR regulation and AV conduction acceleration by the β-adrenergic system (SAS) is unclear. In the present study, L- (I Ca-L ) and T-type (I Ca-T ) Ca 2+ currents were recorded in SANCs from Cav3.1 transgenic (TG) and knockout (KO), and control mice. I Ca-T was absent in KO SANCs but enhanced in TG SANCs. In anaesthetized animals, different doses of isoproterenol (ISO) were infused via the jugular vein and the HR was recorded. The EC 50 of the HR response to ISO was lower in TG mice but higher in KO mice, and the maximal percentage of HR increase by ISO was greater in TG mice but less in KO mice. In Langendorff-perfused hearts, ISO increased HR and shortened PR intervals to a greater extent in TG but to a less extent in KO hearts. KO SANCs had significantly slower spontaneous beating rates than control SANCs before and after

  15. Individually Coded Telemetry: a Tool for Studying Heart Rate and Behaviour in Reindeer Calves

    Directory of Open Access Journals (Sweden)

    Pudas T

    2002-09-01

    Full Text Available The aim of the study was to test the performance of a silver wire modified version of the coded telemetric heart rate monitor Polar Vantage NV™ (PVNV and to measure heart rate (HR in a group of captive reindeer calves during different behaviour. The technical performance of PVNV HR monitors was tested in cold conditions (-30°C using a pulse generator and the correlation between generated pulse and PVNV values was high (r = 0.9957. The accuracy was tested by comparing the HR obtained with the PVNV monitor with the standard ECG, and the correlation was significant (r = 0.9965. Both circadian HR and HR related to behavioural pattern were recorded. A circadian rhythm was observed in the HR in reindeer with a minimum during night and early morning hours and maximum at noon and during the afternoon, the average HR of the reindeer calves studied being 42.5 beats/min in February. The behaviour was recorded by focal individual observations and the data was synchronized with the output of the HR monitors. Running differed from all other behavioural categories in HR. Inter-individual differences were seen expressing individual responses to external and internal stimuli. The silver wire modified Polar Vantage NV™ provides a suitable and reliable tool for measuring heart rate in reindeer, also in natural conditions.

  16. The heart field effect: Synchronization of healer-subject heart rates in energy therapy.

    Science.gov (United States)

    Bair, Christine Caldwell

    2008-01-01

    Recent health research has focused on subtle energy and vibrational frequency as key components of health and healing. In particular, intentional direction of bioenergy is receiving increasing scientific attention. This study investigates the effect of the healer's electromagnetic (EM) heart field upon subjects during energy healing as measured by synchronization of heart rates and scores on a Subjective Units of Distress (SUD) scale and a Profile of Mood States (POMS) inventory. A nonequivalent pretest-posttest design was used based on heart rate comparisons between healer and subject and correlated with pre-and posttest SUD and POMS scores. Subjects included those who sat within the 3- to 4-foot "strong" range of the independent variable, the healer's heart field, while performing self-application of WHEE (the wholistic hybrid derived from EMDR [eye movement desensitization and reprocessing], and EFT [emotional freedom technique]), a meridian-based tapping technique (n=50); and those who performed the same process beyond the 15- to 18-foot range of the healer's EM heart field (n=41). The dependent variables were heart rate, SUD, and POMS inventory. All subjects completed these measures within 1 hour. Study results showed statistically significant heart-rate synchronization with the intervention population. In addition, SUD and POMS scores demonstrated considerably more improvement than in the control population, indicating additional benefit beyond the meridian-based therapies, such as WHEE, alone. Additional findings and future research recommendations are presented in this article.

  17. Learning by Heart: Students Use Heart Rate Patterns To Identify Nervous System Imbalances.

    Science.gov (United States)

    Ackerly, Spafford C.

    2001-01-01

    Introduces a science unit on heart rate variability (HVR) patterns. Uses spectral analysis to determine the effects of environmental stimulants such as music and emotional stress on heart rate. Observes relaxation techniques and their effects on the autonomous nervous system. (Contains 12 references.) (YDS)

  18. [Resonance hypothesis of heart rate variability origin].

    Science.gov (United States)

    Sheĭkh-Zade, Iu R; Mukhambetaliev, G Kh; Cherednik, I L

    2009-09-01

    A hypothesis is advanced of the heart rate variability being subjected to beat-to-beat regulation of cardiac cycle duration in order to ensure the resonance interaction between respiratory and own fluctuation of the arterial system volume for minimization of power expenses of cardiorespiratory system. Myogenic, parasympathetic and sympathetic machanisms of heart rate variability are described.

  19. Safety and efficacy of a drug regimen to control heart rate during 64-slice ECG-gated coronary CTA in children

    International Nuclear Information System (INIS)

    Rigsby, Cynthia K.; Nicholas, Angela C.; deFreitas, R.A.; Leidecker, Christianne; Johanek, Andrew J.; Anley, Peter; Wang, Deli; Uejima, Tetsu

    2010-01-01

    The adult practice for ECG-gated single-source 64-slice coronary CTA (CCTA) includes administering beta-blockers to reduce heart rate. There are limited data on this process in children. To evaluate the safety and efficacy of a drug regimen to decrease heart rate before performing CCTA in children. IV remifentanil and esmolol infusion were chosen to decrease heart rate in 41 children (mean age 6.5 years) while they were under general anesthesia (GA) for CCTA. Drug doses, changes in heart rate and procedural complications were recorded. CCTA image quality was graded on a scale of 1 to 5. The relationships between image quality and heart rate and image quality and age were evaluated. Patient effective radiation doses were calculated. Heart rates were lowered utilizing esmolol (4 children), remifentanil (2 children) or both (35 children); 26 children received nitroglycerin for coronary vasodilation. The mean decrease in heart rate was 26%. There were no major complications. The average image-quality score was 4.4. Higher heart rates were associated with worse image quality (r = 0.67, P < 0.0001). Older age was associated with better image quality (r = 0.66, P < 0.0001). Effective radiation doses were 0.7 to 7.0 mSv. Heart rate reduction for pediatric CCTA can be safely and effectively achieved while yielding high-quality images. (orig.)

  20. Accuracy of Heart Rate Watches: Implications for Weight Management.

    Directory of Open Access Journals (Sweden)

    Matthew P Wallen

    Full Text Available Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established.To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha to measure heart rate and energy expenditure at rest and during exercise.Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate and indirect calorimetry (energy expenditure.None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98] and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]. All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9% but greater for energy expenditure (9-43%. Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm than energy expenditure (ranging from -266.7 to 65.7 kcals across devices.These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  1. Accuracy of Heart Rate Watches: Implications for Weight Management.

    Science.gov (United States)

    Wallen, Matthew P; Gomersall, Sjaan R; Keating, Shelley E; Wisløff, Ulrik; Coombes, Jeff S

    2016-01-01

    Wrist-worn monitors claim to provide accurate measures of heart rate and energy expenditure. People wishing to lose weight use these devices to monitor energy balance, however the accuracy of these devices to measure such parameters has not been established. To determine the accuracy of four wrist-worn devices (Apple Watch, Fitbit Charge HR, Samsung Gear S and Mio Alpha) to measure heart rate and energy expenditure at rest and during exercise. Twenty-two healthy volunteers (50% female; aged 24 ± 5.6 years) completed ~1-hr protocols involving supine and seated rest, walking and running on a treadmill and cycling on an ergometer. Data from the devices collected during the protocol were compared with reference methods: electrocardiography (heart rate) and indirect calorimetry (energy expenditure). None of the devices performed significantly better overall, however heart rate was consistently more accurate than energy expenditure across all four devices. Correlations between the devices and reference methods were moderate to strong for heart rate (0.67-0.95 [0.35 to 0.98]) and weak to strong for energy expenditure (0.16-0.86 [-0.25 to 0.95]). All devices underestimated both outcomes compared to reference methods. The percentage error for heart rate was small across the devices (range: 1-9%) but greater for energy expenditure (9-43%). Similarly, limits of agreement were considerably narrower for heart rate (ranging from -27.3 to 13.1 bpm) than energy expenditure (ranging from -266.7 to 65.7 kcals) across devices. These devices accurately measure heart rate. However, estimates of energy expenditure are poor and would have implications for people using these devices for weight loss.

  2. Simultaneous measurement of instantaneous heart rate and chest wall plethysmography in short-term, metronome guided heart rate variability studies: suitability for assessment of autonomic dysfunction.

    Science.gov (United States)

    Perring, S; Jones, E

    2003-08-01

    Instantaneous heart rate and chest wall motion were measured using a 3-lead ECG and an air pressure chest wall plethysmography system. Chest wall plethysmography traces were found to accurately represent the breathing pattern as measured by spirometry (average correlation coefficient 0.944); though no attempt was made to calibrate plethysmography voltage output to tidal volume. Simultaneous measurements of heart rate and chest wall motion were made for short periods under metronome guided breathing at 6 breaths per minute. The average peak to trough heart rate change per breath cycle (AVEMAX) and maximum correlation between heart rate and breathing cycle (HRBRCORR) were measured. Studies of 44 normal volunteers indicated clear inverse correlation of heart rate variability parameters with age (AVEMAX R = -0.502, P < 0.001) but no significant change in HRBRCORR with age (R = -0.115). Comparison of normal volunteers with diabetics with no history of symptoms associated with autonomic failure indicated significant lower heart rate variability in diabetics (P = 0.005 for AVEMAX) and significantly worse correlation between heart rate and breathing (P < 0.001 for HRBRCORR). Simultaneous measurement of heart rate and breathing offers the possibility of more sensitive diagnosis of autonomic failure in a simple bedside test and gives further insight into the nature of cardio-ventilatory coupling.

  3. Leukocyte Populations are Associated with Heart Rate Variability After a Triathlon

    Directory of Open Access Journals (Sweden)

    Cruz Germán Hernández

    2016-12-01

    Full Text Available The purpose of this study was to analyze cellular immune components and their association with heart rate variability in triathlon athletes. Twelve athletes were included (age 36.41 ± 5.57 years, body mass 81.84 ± 10.97 kg and blood samples were taken one week before, immediately, at 2 and 48 hours, and one week after competition. Total lymphocytes and their subpopulations, neutrophils, basophils, eosinophils and monocytes were analyzed. At the same time, heart rate variability was recorded for 30 minutes using Polar Team2®. A significant difference between lymphocyte subpopulations and heart rate variability was found in the different study periods. A positive correlation was found between total lymphocytes and rMSSD (r = .736, p <0.05, CD3+ and rMSSD (r = .785, p <0.05, and CD4+ and rMSSD (r = .795, p < 0.05 at the end of the competition. After one week of competition, a negative correlation was found between eosinophils and MRR, SDNN, pNN50, and rMSSD (p <0.01; and basophils and MRR, SDNN, pNN50, and rMSSD (p <0.01; while a positive correlation was found between CD19+ (B cells and pNN50 (r = .678, p <0.05. Our results suggest that it is possible to predict the effect of training with regard to the athlete's performance.

  4. Heart Rate Fragmentation: A Symbolic Dynamical Approach

    Directory of Open Access Journals (Sweden)

    Madalena D. Costa

    2017-11-01

    Full Text Available Background: We recently introduced the concept of heart rate fragmentation along with a set of metrics for its quantification. The term was coined to refer to an increase in the percentage of changes in heart rate acceleration sign, a dynamical marker of a type of anomalous variability. The effort was motivated by the observation that fragmentation, which is consistent with the breakdown of the neuroautonomic-electrophysiologic control system of the sino-atrial node, could confound traditional short-term analysis of heart rate variability.Objective: The objectives of this study were to: (1 introduce a symbolic dynamical approach to the problem of quantifying heart rate fragmentation; (2 evaluate how the distribution of the different dynamical patterns (“words” varied with the participants' age in a group of healthy subjects and patients with coronary artery disease (CAD; and (3 quantify the differences in the fragmentation patterns between the two sample populations.Methods: The symbolic dynamical method employed here was based on a ternary map of the increment NN interval time series and on the analysis of the relative frequency of symbolic sequences (words with a pre-defined set of features. We analyzed annotated, open-access Holter databases of healthy subjects and patients with CAD, provided by the University of Rochester Telemetric and Holter ECG Warehouse (THEW.Results: The degree of fragmentation was significantly higher in older individuals than in their younger counterparts. However, the fragmentation patterns were different in the two sample populations. In healthy subjects, older age was significantly associated with a higher percentage of transitions from acceleration/deceleration to zero acceleration and vice versa (termed “soft” inflection points. In patients with CAD, older age was also significantly associated with higher percentages of frank reversals in heart rate acceleration (transitions from acceleration to

  5. Comparison of O2 saturation, heart and respiratory rate following injection of vasoconstrictor containing anesthetic (lidocaine 2% and without vasoconstrictor anesthetic (Mepivacaine

    Directory of Open Access Journals (Sweden)

    Bayat M.

    2005-07-01

    Full Text Available Background and Aim: Along with higher usage of dental local anesthesia with risks to people health together with their positive role, the important goal of dentistry, patients’ health, has been stressed repeatedly nowadays. This study was conducted to compare O2 saturation, respiratory rate and heart rate of patients following injection of anesthetic containing vasoconstrictor (lidocaine 2% and without vasoconstrictor (Mepivacaine. Materials and Methods: This experimental study was conducted on 32 healthy humans (16 females and 16 males with 25-50 years age range and no history of drug usage. Cases were classified into two matched groups. O2 saturation, heart and respiratory rate were recorded before extraction of a mandibular posterior tooth. In the first group, 3.6 ml lidocaine 2% with 1:80,000 epinephrine and in the second group Mepivacaine 3% was injected, using inferior alveolar dental nerve block with aspiration. Variables were measured and recorded. Tooth extraction was performed and the mentioned variables were recorded again. Data were analyzed with SPSS software using t and Paired t-test with P<0.05 as the limit of significance. Results: After injection of lidocaine, the heart rate was increased (12.25±1.75 bpm, and the time to reach the maximum rate was 64.75±11.26 seconds. After extraction of tooth, heart rate in both groups was increased not considering the type of injection. Conclusion: The study showed that the injection of lidocaine (containing epinephrine in patients without contraindication has no risk. Also, possible increase in heart rate is not risky and is not associated with O2 saturation decrease and respiratory interruption.

  6. Resting and postexercise heart rate variability in professional handball players.

    Science.gov (United States)

    Kayacan, Yildirim; Yildiz, Sedat

    2016-03-01

    The aim of this study was to evaluate heart rate variability (HRV) in professional handball players during rest and following a 5 min mild jogging exercise. For that purpose, electrocardiogram (ECG) of male handball players (N.=12, mean age 25±3.95 years) and sedentary controls (N.=14, mean age 23.5±2.95 years) were recorded for 5 min at rest and just after 5 min of mild jogging. ECGs were recorded and following HRV parameters were calculated: time-domain variables such as heart rate (HR), average normal-to-normal RR intervals, standard deviation of normal-to-normal RR intervals, square root of the mean of the squares of differences between adjacent NN intervals, percentage of differences between adjacent NN intervals that are greater than 50 milliseconds (pNN50), and frequency-domain variables such as very low frequency, low (LF) and high frequency (HF) of the power and LF/HF ratio. Unpaired t-test was used to find out differences among groups while paired t-test was used for comparison of each group for pre- and postjogging HRV. Pearson correlations were carried out to find out the relationships between the parameters. Blood pressures were not different between handball players and sedentary controls but exercise increased systolic blood pressure (Phandball players (Phandball players (Phandball players in response to a mild, short-time (5 min) jogging exercise. However, in sedentary subjects, either the sympathetic regulation of the autonomous nervous system increased or vagal withdrawal occurred.

  7. State Anxiety and Nonlinear Dynamics of Heart Rate Variability in Students.

    Science.gov (United States)

    Dimitriev, Dimitriy A; Saperova, Elena V; Dimitriev, Aleksey D

    2016-01-01

    Clinical and experimental research studies have demonstrated that the emotional experience of anxiety impairs heart rate variability (HRV) in humans. The present study investigated whether changes in state anxiety (SA) can also modulate nonlinear dynamics of heart rate. A group of 96 students volunteered to participate in the study. For each student, two 5-minute recordings of beat intervals (RR) were performed: one during a rest period and one just before a university examination, which was assumed to be a real-life stressor. Nonlinear analysis of HRV was performed. The Spielberger's State-Trait Anxiety Inventory was used to assess the level of SA. Before adjusting for heart rate, a Wilcoxon matched pairs test showed significant decreases in Poincaré plot measures, entropy, largest Lyapunov exponent (LLE), and pointwise correlation dimension (PD2), and an increase in the short-term fractal-like scaling exponent of detrended fluctuation analysis (α1) during the exam session, compared with the rest period. A Pearson analysis indicated significant negative correlations between the dynamics of SA and Poincaré plot axes ratio (SD1/SD2), and between changes in SA and changes in entropy measures. A strong negative correlation was found between the dynamics of SA and LLE. A significant positive correlation was found between the dynamics of SA and α1. The decreases in Poincaré plot measures (SD1, complex correlation measure), entropy measures, and LLE were still significant after adjusting for heart rate. Corrected α1 was increased during the exam session. As before, the dynamics of adjusted LLE was significantly correlated with the dynamics of SA. The qualitative increase in SA during academic examination was related to the decrease in the complexity and size of the Poincaré plot through a reduction of both the interbeat interval and its variation.

  8. State Anxiety and Nonlinear Dynamics of Heart Rate Variability in Students.

    Directory of Open Access Journals (Sweden)

    Dimitriy A Dimitriev

    Full Text Available Clinical and experimental research studies have demonstrated that the emotional experience of anxiety impairs heart rate variability (HRV in humans. The present study investigated whether changes in state anxiety (SA can also modulate nonlinear dynamics of heart rate.A group of 96 students volunteered to participate in the study. For each student, two 5-minute recordings of beat intervals (RR were performed: one during a rest period and one just before a university examination, which was assumed to be a real-life stressor. Nonlinear analysis of HRV was performed. The Spielberger's State-Trait Anxiety Inventory was used to assess the level of SA.Before adjusting for heart rate, a Wilcoxon matched pairs test showed significant decreases in Poincaré plot measures, entropy, largest Lyapunov exponent (LLE, and pointwise correlation dimension (PD2, and an increase in the short-term fractal-like scaling exponent of detrended fluctuation analysis (α1 during the exam session, compared with the rest period. A Pearson analysis indicated significant negative correlations between the dynamics of SA and Poincaré plot axes ratio (SD1/SD2, and between changes in SA and changes in entropy measures. A strong negative correlation was found between the dynamics of SA and LLE. A significant positive correlation was found between the dynamics of SA and α1. The decreases in Poincaré plot measures (SD1, complex correlation measure, entropy measures, and LLE were still significant after adjusting for heart rate. Corrected α1 was increased during the exam session. As before, the dynamics of adjusted LLE was significantly correlated with the dynamics of SA.The qualitative increase in SA during academic examination was related to the decrease in the complexity and size of the Poincaré plot through a reduction of both the interbeat interval and its variation.

  9. Hyperthyroidism is characterized by both increased sympathetic and decreased vagal modulation of heart rate: evidence from spectral analysis of heart rate variability.

    Science.gov (United States)

    Chen, Jin-Long; Chiu, Hung-Wen; Tseng, Yin-Jiun; Chu, Woei-Chyn

    2006-06-01

    The clinical manifestations of hyperthyroidism resemble those of the hyperadrenergic state. This study was designed to evaluate the impact of hyperthyroidism on the autonomic nervous system (ANS) and to investigate the relationship between serum thyroid hormone concentrations and parameters of spectral heart rate variability (HRV) analysis in hyperthyroidism. Thirty-two hyperthyroid Graves' disease patients (mean age 31 years) and 32 sex-, age-, and body mass index (BMI)-matched normal control subjects were recruited to receive one-channel electrocardiogram (ECG) recording. The cardiac autonomic nervous function was evaluated by the spectral analysis of HRV, which indicates the autonomic modulation of the sinus node. The correlation coefficients between serum thyroid hormone concentrations and parameters of the spectral HRV analysis were also computed. The hyperthyroid patients revealed significant differences (P hyperthyroidism in 28 patients, all of the above parameters were restored to levels comparable to those of the controls. In addition, serum thyroid hormone concentrations showed significant correlations with spectral HRV parameters. Hyperthyroidism is in a sympathovagal imbalanced state, characterized by both increased sympathetic and decreased vagal modulation of the heart rate. These autonomic dysfunctions can be detected simultaneously by spectral analysis of HRV, and the spectral HRV parameters could reflect the disease severity in hyperthyroid patients.

  10. Heart rate and time-motion analyses in top junior players during basketball matches

    Directory of Open Access Journals (Sweden)

    Karel Hůlka

    2013-09-01

    Full Text Available BACKGROUND: Basketball performance can be classified as an intermittent physical activity due to the changing situational game conditions and the number of intervening variables. It is necessary to have detailed knowledge about the performance of basketball players during a match as a background for more specific planning of the training process. OBJECTIVE: The aim of this study was to analyse the indicators of internal and external load of basketball player’s performance during a match of U18 top men basketball players as a background for the planning of specific training processes. METHODS: Thirty-two Czech top junior basketball players (male, aged 16.88 ± 0.72 years participated in this research. The heart rate was recorded and time-motion analysis was conducted during six warm-up matches. RESULTS: The average heart rate was measured to be 167.47 ± 13.01 beats • min.–1, which corresponded to 85.06 ± 6.40% of peak heart rate. The percentages of the total time spent over and under 85% were 63.12% and 36.88%, respectively. Average distance covered was measured to be 5,880.91 ± 831.01 meters. The average work : rest ratio was 1 : 7.95 ± 1.83, ranging from 1 : 4.80 to 1 : 10.92. CONCLUSIONS: The results from these matches suggest that the exercise intensity and sprint activity observed during junior basketball are dependent on the player's position and partly on the level of the performance. The heart rate during a match was not dependent on the positions, however, time-motion analysis revealed significant differences between three basketball positions during a match. The combination of heart rate and time-motion analysis is recommended.

  11. Heart rate and lactate response of junior handball players (Under 18 during competitive match play

    Directory of Open Access Journals (Sweden)

    Subir Gupta

    2017-08-01

    Full Text Available Background: This study highlights the heart rate (HR and blood lactate (La response of junior handball players of two positions – wings and backs, during competitive matches. Methods: Heart rate and blood lactate of twelve handball players – 6 Backs (B and 6 Wingers (W] – were recorded in quarter- and semifinal matches of the tournament. HR was recorded continuously by heart rate telemeter whereas La was measured at rest, after warm up and immediately after the end of first- and second halves of the matches. Results: Average HR and Maximum Heart Rate Reserve (MHRR of the players were similar in each half of play. No significant difference (p<0.05 in average HR and MHRR were observed between B (169±17.5 beats/min and 74.3±9.4% and W (169.5±16.3 beats/min and 74.1±8.5%. W and B played about 1/5th of their playing time above the Anerobic Threshold level. Average HR of the players in each 5 min of play could vary significantly but no such difference per 15 min of play was found. Lactate of W and B after the first half of play were 7.4±1.6 and 7.2±1.5 mM and after the end of the matches were 7.9±0.4 and 7.6±1.4 mM respectively. No significant difference in La was found between W and B. Conclusion: (a Handball play is a high intensity game, (b the workload does not vary between W and B, (c the intensity of play could vary in every 5 min of play but there is no difference in average intensity for each 15 min, and (d handball is played aerobically for majority of the time.

  12. Comparing low frequency heart rate variability and preejection period: Two sides of a different coin.

    NARCIS (Netherlands)

    Goedhart, A.D.; Willemsen, G.; Houtveen, J.H.; Boomsma, D.I.; de Geus, E.J.C.

    2008-01-01

    It has been hypothesized that the ratio of heart rate variability in the low- (LF) and high- (HF) frequency bands may capture variation in cardiac sympathetic control. Here we tested the temporal stability of the LF/HF ratio in 24-h ambulatory recordings and compared this ratio to the preejection

  13. Effect of oxygen treatment on heart rate after abdominal surgery

    DEFF Research Database (Denmark)

    Rosenberg-Adamsen, S; Lie, C; Bernhard, A

    1999-01-01

    BACKGROUND: Cardiac complications are common during the postoperative period and may be associated with hypoxemia and tachycardia. Preliminary studies in high-risk patients after operation have shown a possible beneficial effect of oxygen therapy on arterial oxygen saturation and heart rate....... METHODS: The authors studied the effect of oxygen therapy on arterial oxygen saturation and heart rate in 100 consecutive unselected patients randomly and double blindly allocated to receive air or oxygen therapy between the first and fourth day after major abdominal surgery. RESULTS: The median arterial...... oxygen saturation rate increased significantly from 96% to 99% (P heart rate decreased significantly from 85 beats/min to 81 beats/min (P heart rate occurred...

  14. Paradoxical dissociation between heart rate and heart rate variability following different modalities of exercise in individuals with metabolic syndrome: The RESOLVE study.

    Science.gov (United States)

    Boudet, Gil; Walther, Guillaume; Courteix, Daniel; Obert, Philippe; Lesourd, Bruno; Pereira, Bruno; Chapier, Robert; Vinet, Agnès; Chamoux, Alain; Naughton, Geraldine; Poirier, Paul; Dutheil, Frédéric

    2017-02-01

    Aims To analyse the effects of different modalities of exercise training on heart rate variability (HRV) in individuals with metabolic syndrome (MetS). Methods and results Eighty MetS participants (aged 50-70 years) were housed and managed in an inpatient medical centre for 21 days, including weekends. Physical activity and food intake/diet were intensively monitored. Participants were randomly assigned into three training groups, differing only by intensity of exercise: moderate-endurance-moderate-resistance ( re), high-resistance-moderate-endurance ( Re), and moderate-resistance-high-endurance ( rE). HRV was recorded before and after the intervention by 24-hour Holter electrocardiogram. Although mean 24-hour heart rate decreased more in Re than re (-11.6 ± 1.6 vs. -4.8 ± 2.1%; P = 0.010), low frequency/high frequency decreased more in re than Re (-20.4 ± 5.5% vs. + 20.4 ± 9.1%; P = 0.002) and rE (-20.4 ± 5.5% vs. -0.3 ± 11.1%; P = 0.003). Very low frequency increased more in Re than re (+121.2 ± 35.7 vs. 42.9 ± 11.3%; P = 0.004). For all HRV parameters, rE ranged between re and Re values. Low frequency/high frequency changes were linked with visceral fat loss only in re (coefficient 5.9, 95% CI 1.9-10.0; P = 0.004). By day 21, HRV parameters of MetS groups (heart rate -8.6 ± 1.0%, standard deviation of R-R intervals + 34.0 ± 6.6%, total power + 63.3 ± 11.1%; P < 0.001) became closer to values of 50 aged-matched healthy controls. Conclusions A 3-week residential programme with intensive volumes of physical activity (15-20 hours per week) enhanced HRV in individuals with MetS. Participants with moderate intensity of training had greater improvements in sympathovagal balance, whereas those with high intensity in resistance training had greater decreases in heart rate and greater increases in very low frequency. Modality-specific relationships were observed between enhanced HRV

  15. Changes of heart rate variability and prefrontal oxygenation during Tai Chi practice versus arm ergometer cycling.

    Science.gov (United States)

    Lu, Xi; Hui-Chan, Christina Wan-Ying; Tsang, William Wai-Nam

    2016-11-01

    [Purpose] Exercise has been shown to improve cardiovascular fitness and cognitive function. Whether the inclusion of mind over exercise would increase parasympathetic control of the heart and brain activities more than general exercise at a similar intensity is not known. The aim of this study was to compare the effects of Tai Chi (mind-body exercise) versus arm ergometer cycling (body-focused exercise) on the heart rate variability and prefrontal oxygenation level. [Subjects and Methods] A Tai Chi master was invited to perform Tai Chi and arm ergometer cycling with similar exercise intensity on two separate days. Heart rate variability and prefrontal oxyhemoglobin levels were measured continuously by a RR recorder and near-infrared spectroscopy, respectively. [Results] During Tai Chi exercise, spectral analysis of heart rate variability demonstrated a higher high-frequency power as well as a lower low-frequency/high-frequency ratio than during ergometer cycling, suggesting increased parasympathetic and decreased sympathetic control of the heart. Also, prefrontal oxyhemoglobin and total hemoglobin levels were higher than those during arm ergometer exercise. [Conclusion] These findings suggest that increased parasympathetic control of the heart and prefrontal activities may be associated with Tai Chi practice. Having a "mind" component in Tai Chi could be more beneficial for older adults' cardiac health and cognitive function than body-focused ergometer cycling.

  16. Analyses of heart rate variability in young soccer players: the effects of sport activity.

    Science.gov (United States)

    Bricout, Véronique-Aurélie; Dechenaud, Simon; Favre-Juvin, Anne

    2010-04-19

    The use of heart rate variability (HRV) in the management of sport training is a practice which tends to spread, especially in order to prevent the occurrence of states of fatigue. To estimate the HRV parameters obtained using a heart rate recording, according to different loads of sporting activities, and to make the possible link with the appearance of fatigue. Eight young football players, aged 14.6 years+/-2 months, playing at league level in Rhône-Alpes, training for 10 to 20 h per week, were followed over a period of 5 months, allowing to obtain 54 recordings of HRV in three different conditions: (i) after rest (ii) after a day with training and (iii) after a day with a competitive match. Under the effect of a competitive match, the HRV temporal indicators (heart rate, RR interval, and pNN50) were significantly altered compared to the rest day. The analysis of the sympathovagal balance rose significantly as a result of the competitive constraint (0.72+/-0.17 vs. 0.90+/-0.20; pHRV is an objective and non-invasive monitoring of management of the training of young sportsmen. HRV analysis allowed to highlight any neurovegetative adjustments according to the physical loads. Thus, under the effect of an increase of physical and psychological constraints that a football match represents, the LF/HF ratio rises significantly; reflecting increased sympathetic stimulation, which beyond certain limits could be relevant to prevent the emergence of a state of fatigue. 2009 Elsevier B.V. All rights reserved.

  17. Blood Pressure vs. Heart Rate

    Science.gov (United States)

    ... Peripheral Artery Disease Venous Thromboembolism Aortic Aneurysm More Blood Pressure vs. Heart Rate (Pulse) Updated:Nov 13,2017 ... This content was last reviewed October 2016. High Blood Pressure • Home • Get the Facts About HBP Introduction What ...

  18. Human care system for heart-rate and human-movement trajectory in home and its application to detect mental disease

    Science.gov (United States)

    Hata, Yutaka; Kanazawa, Seigo; Endo, Maki; Tsuchiya, Naoki; Nakajima, Hiroshi

    2012-06-01

    This paper proposes a heart rate monitoring system for detecting autonomic nervous system by the heart rate variability using an air pressure sensor to diagnose mental disease. Moreover, we propose a human behavior monitoring system for detecting the human trajectory in home by an infrared camera. In day and night times, the human behavior monitoring system detects the human movement in home. The heart rate monitoring system detects the heart rate in bed in night time. The air pressure sensor consists of a rubber tube, cushion cover and pressure sensor, and it detects the heart rate by setting it to bed. It unconstraintly detects the RR-intervals; thereby the autonomic nervous system can be assessed. The autonomic nervous system analysis can examine the mental disease. While, the human behavior monitoring system obtains distance distribution image by an infrared camera. It classifies adult, child and the other object from distance distribution obtained by the camera, and records their trajectories. This behavior, i.e., trajectory in home, strongly corresponds to cognitive disorders. Thus, the total system can detect mental disease and cognitive disorders by uncontacted sensors to human body.

  19. Examination of a Novel Method for Non-Contact, Low-Cost, and Automated Heart-Rate Detection in Ambient Light Using Photoplethysmographic Imaging

    Science.gov (United States)

    2014-10-01

    Unclassified 19b. TELEPHONE NUMBER (Include area code ) 407-208-5693 Standard Form 298 (Rev. 8/98) Prescribed by ANSI Std. Z39.18 iii...more intrusive than those recording facial and vocal expression. For example, to measure heart rate (HR) or heart rate variability (HRV), the subject...during surgery . Capnographs monitor respiratory status 2 and pulse of patients during anesthesia and intensive care. These methods are proven

  20. Heart rate and heart rate variability modification in chronic insomnia patients.

    Science.gov (United States)

    Farina, Benedetto; Dittoni, Serena; Colicchio, Salvatore; Testani, Elisa; Losurdo, Anna; Gnoni, Valentina; Di Blasi, Chiara; Brunetti, Riccardo; Contardi, Anna; Mazza, Salvatore; Della Marca, Giacomo

    2014-01-01

    Chronic insomnia is highly prevalent in the general population, provoking personal distress and increased risk for psychiatric and medical disorders. Autonomic hyper-arousal could be a pathogenic mechanism of chronic primary insomnia. The aim of this study was to investigate autonomic activity in patients with chronic primary insomnia by means of heart rate variability (HRV) analysis. Eighty-five consecutive patients affected by chronic primary insomnia were enrolled (38 men and 47 women; mean age: 53.2 ± 13.6). Patients were compared with a control group composed of 55 healthy participants matched for age and gender (23 men and 32 women; mean age: 54.2 ± 13.9). Patients underwent an insomnia study protocol that included subjective sleep evaluation, psychometric measures, and home-based polysomnography with evaluation of HRV in wake before sleep, in all sleep stages, and in wake after final awakening. Patients showed modifications of heart rate and HRV parameters, consistent with increased sympathetic activity, while awake before sleep and during Stage-2 non-REM sleep. No significant differences between insomniacs and controls could be detected during slow-wave sleep, REM sleep, and post-sleep wake. These results are consistent with the hypothesis that autonomic hyper-arousal is a major pathogenic mechanism in primary insomnia, and confirm that this condition is associated with an increased cardiovascular risk.

  1. Low vagally-mediated heart rate variability and increased susceptibility to ventricular arrhythmias in rats bred for high anxiety.

    Science.gov (United States)

    Carnevali, Luca; Trombini, Mimosa; Graiani, Gallia; Madeddu, Denise; Quaini, Federico; Landgraf, Rainer; Neumann, Inga D; Nalivaiko, Eugene; Sgoifo, Andrea

    2014-04-10

    In humans, there is a documented association between anxiety disorders and cardiovascular disease. Putative underlying mechanisms may include an impairment of the autonomic nervous system control of cardiac function. The primary objective of the present study was to characterize cardiac autonomic modulation and susceptibility to arrhythmias in genetic lines of rats that differ largely in their anxiety level. To reach this goal, electrocardiographic recordings were performed in high-anxiety behavior (HAB, n=10) and low-anxiety behavior (LAB, n=10) rats at rest, during stressful stimuli and under autonomic pharmacological manipulations, and analyzed by means of time- and frequency-domain indexes of heart rate variability. During resting conditions, HAB rats displayed a reduced heart rate variability, mostly in terms of lower parasympathetic (vagal) modulation compared to LAB rats. In HAB rats, this relatively low cardiac vagal control was associated with smaller heart rate responsiveness to acute stressors compared to LAB counterparts. In addition, beta-adrenergic pharmacological stimulation induced a larger incidence of ventricular tachyarrhythmias in HABs compared to LABs. At sacrifice, a moderate increase in heart-body weight ratio was observed in HAB rats. We conclude that high levels of anxiety-related behavior in rats are associated with signs of i) impaired autonomic modulation of heart rate (low vagally-mediated heart rate variability), ii) poor adaptive heart rate responsiveness to stressful stimuli, iii) increased arrhythmia susceptibility, and iv) cardiac hypertrophy. These results highlight the utility of the HAB/LAB model for investigating the mechanistic basis of the comorbidity between anxiety disorders and cardiovascular disease. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Exaggerated heart rate oscillations during two meditation techniques.

    Science.gov (United States)

    Peng, C K; Mietus, J E; Liu, Y; Khalsa, G; Douglas, P S; Benson, H; Goldberger, A L

    1999-07-31

    We report extremely prominent heart rate oscillations associated with slow breathing during specific traditional forms of Chinese Chi and Kundalini Yoga meditation techniques in healthy young adults. We applied both spectral analysis and a novel analytic technique based on the Hilbert transform to quantify these heart rate dynamics. The amplitude of these oscillations during meditation was significantly greater than in the pre-meditation control state and also in three non-meditation control groups: i) elite athletes during sleep, ii) healthy young adults during metronomic breathing, and iii) healthy young adults during spontaneous nocturnal breathing. This finding, along with the marked variability of the beat-to-beat heart rate dynamics during such profound meditative states, challenges the notion of meditation as only an autonomically quiescent state.

  3. Inhibition of sarcoplasmic reticulum Ca(2+)-ATPase decreases atrioventricular node-paced heart rate in rabbits.

    Science.gov (United States)

    Cheng, Hongwei; Smith, Godfrey L; Orchard, Clive H; Hancox, Jules C; Burton, Francis L

    2012-10-01

    Recent data indicate that Ca(2+) cycling in isolated atrioventricular node (AVN) cells contributes to setting spontaneous rate. The aim of the present study was to extend this observation to the intact AVN in situ, by evaluating the effects of inhibiting sarcoplasmic reticulum Ca(2+) uptake with cyclopiazonic acid (CPA) on intact AVN spontaneous activity and its response to isoprenaline. A model of the AVN-paced heart was produced to investigate intact AVN automaticity, by surgical ablation of the sino-atrial node (SAN) in the rabbit Langendorff-perfused heart. Electrograms were recorded from a site close to the AVN (triangle of Koch), an atrial site above the AVN, the left atrium and right ventricle, enabling AVN pacing of the preparation to be confirmed. Before SAN ablation, the heart rate was 166.8 ± 5.4 beats min(-1). Ablation of the SAN was clearly indicated by a sudden and significant decrease of heart rate to 108.6 ± 9.6 beats min(-1) (P AVN rate to 187.8 ± 12.0 beats min(-1) after 1 min of application (P AVN rate to 81.6 ± 4.8 (n = 9) and 77.4 ± 6.0 beats min(-1) (n = 7), respectively [P AVN rate increase in response to isoprenaline from 78.8 ± 10.0 to 46.8 ± 6.8 and 26.7 ± 5.3%, respectively (P AVN rate and its response to isoprenaline indicate that Ca(2+) cycling is important to the intact AVN spontaneous activity and its acceleration during sympathetic stimulation.

  4. Association of heart rate profile during exercise with the severity of coronary artery disease.

    Science.gov (United States)

    Cay, Serkan; Ozturk, Sezgin; Biyikoglu, Funda; Yildiz, Abdulkadir; Cimen, Tolga; Uygur, Belma; Tuna, Funda

    2009-05-01

    Coronary artery disease is the leading cause of morbidity and mortality around the world. Autonomic nervous system abnormalities are associated with coronary artery disease and its complications. Exercise stress tests are routinely used for the detection of the presence of coronary artery disease. In this study, we observed the association between heart rate profile during exercise and the severity of coronary artery disease. One hundred and sixty patients with abnormal exercise treadmill test (> or =1 mm horizontal or downsloping ST-segment depression; 119 men, 41 women; mean age = 57 +/- 9 years) were included in the study. Use of any drug affecting heart rate was not permitted. Resting heart rate before exercise, maximum heart rate during exercise, and resting heart rate after exercise (5 min later) were measured and two parameters were calculated: heart rate increment (maximum heart rate - resting heart rate before exercise) and heart rate decrement (maximum heart rate - resting heart rate after exercise). All patients underwent selective coronary angiography and subclassified into two groups according to stenotic lesion severity. Group 1 had at least 50% of stenotic lesion and group 2 had less than 50%. Patients in the first group had increased resting heart rate, decreased maximum heart rate, decreased heart rate increment, and decreased heart rate decrement compared with second group. All patients were classified into tertiles of resting heart rate, heart rate increment, and heart rate decrement level to evaluate whether these parameters were associated with severity of coronary artery stenosis in the study. The multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 21.888 (95% confidence interval 6.983-68.606) for the highest tertile of resting heart rate level compared with the lowest tertile. In addition, the multiple-adjusted odds ratio of the risk of severe coronary atherosclerosis was 20.987 (95% confidence interval 6

  5. Discovery of novel heart rate-associated loci using the Exome Chip

    DEFF Research Database (Denmark)

    van den Berg, Marten E; Warren, Helen R; Cabrera, Claudia P

    2017-01-01

    Resting heart rate is a heritable trait, and an increase in heart rate is associated with increased mortality risk. Genome-wide association study analyses have found loci associated with resting heart rate, at the time of our study these loci explained 0.9% of the variation. This study aims to di......) and fetal muscle samples by including our novel variants.Our findings advance the knowledge of the genetic architecture of heart rate, and indicate new candidate genes for follow-up functional studies....

  6. Dynamic classification of fetal heart rates by hierarchical Dirichlet process mixture models.

    Directory of Open Access Journals (Sweden)

    Kezi Yu

    Full Text Available In this paper, we propose an application of non-parametric Bayesian (NPB models for classification of fetal heart rate (FHR recordings. More specifically, we propose models that are used to differentiate between FHR recordings that are from fetuses with or without adverse outcomes. In our work, we rely on models based on hierarchical Dirichlet processes (HDP and the Chinese restaurant process with finite capacity (CRFC. Two mixture models were inferred from real recordings, one that represents healthy and another, non-healthy fetuses. The models were then used to classify new recordings and provide the probability of the fetus being healthy. First, we compared the classification performance of the HDP models with that of support vector machines on real data and concluded that the HDP models achieved better performance. Then we demonstrated the use of mixture models based on CRFC for dynamic classification of the performance of (FHR recordings in a real-time setting.

  7. Heart rate variability in stroke patients submitted to an acute bout of aerobic exercise.

    Science.gov (United States)

    Raimundo, Rodrigo Daminello; de Abreu, Luiz Carlos; Adami, Fernando; Vanderlei, Franciele Marques; de Carvalho, Tatiana Dias; Moreno, Isadora Lessa; Pereira, Valdelias Xavier; Valenti, Vitor Engracia; Sato, Monica Akemi

    2013-10-01

    Stroke has been associated with cardiac autonomic impairment due to damage in central nervous system. Dysfunction in heart rate variability (HRV) may reflect dysfunction of the autonomic nervous system. Aerobic training has been used in the rehabilitation procedure of patients, due to improvement of aerobic function and other beneficial effects as increased recruitment of motor units, favoring the development of muscle fibers. The purpose of this study was to evaluate the cardiac autonomic modulation in patients with stroke before, during, and after an acute bout of aerobic exercise. The heart rate of 38 stroke patients was recorded using a heart rate (HR) monitor and the data were used to assess cardiac autonomic modulation through HRV analysis. The patients were in supine position and remained at resting condition (R) for 10 min before starting the experiment. Afterwards, they were submitted to walking exercise (E) on a treadmill until achieve 50-70% of maximum heart rate. After 30 min of aerobic exercise, the subjects were advised to remain in supine position for additional 30 min in order to record the HR during the recovery (RC) period. The recordings were divided in three periods: RC1, immediately after the end of exercise bout, RC2, between 12 and 17 min of recovery, and RC3, at the final 5 min of recovery. A significant decrease was observed during exercise in the MeanRR index (577.3±92 vs. 861.1+109), RRtri (5.1±2 vs. 9.1±3), high frequency component (11.2±4 vs. 167±135 ms) and SD1 (5.7±2 vs. 16.9±7 ms) compared to resting values. The SDNN index reduced during E (27.6±19) and RC1 (29.9±11), RC2 (27.9±9) and RC3 (32.4±13) compared to resting values (42.4±19). The low frequency component increased during E (545±82), but decreased during RC1 (166.3±129), RC2 (206.9±152), and RC3 (249.5±236) compared to R levels (394.6±315). These findings suggest that stroke patients showed a reduced HRV during and at least 30 min after exercise, due to an

  8. A randomised, simulated study assessing auscultation of heart rate at birth

    NARCIS (Netherlands)

    Voogdt, Kevin G. J. A.; Morrison, Allison C.; Wood, Fiona E.; van Elburg, Ruurd M.; Wyllie, Jonathan P.

    2010-01-01

    Heart rate is a primary clinical indicator directing newborn resuscitation. The time taken to assess the heart rate by auscultation in relation to accuracy during newborn resuscitation is not known. To assess both the accuracy and time taken to assess heart rate by stethoscope in simulated

  9. Task demands and the pressures of everyday life: associations between cardiovascular reactivity and work blood pressure and heart rate.

    Science.gov (United States)

    Steptoe, A; Cropley, M; Joekes, K

    2000-01-01

    Associations between cardiovascular stress reactivity and blood pressure and heart rate recorded in everyday life were hypothesized to depend on the stressfulness of the ambulatory monitoring period relative to standardized tasks and on activity levels at the time of measurement. One hundred two female and 60 male school teachers carried out high- and low-demand tasks under standardized conditions and ambulatory monitoring during the working day. Stress ratings during the day were close to those recorded during the low-demand task. Reactions to the low-demand task were significant predictors of ambulatory blood pressure and heart rate independent of baseline, age, gender, and body mass. Associations were more consistent for ambulatory recordings taken when participants were seated than when they were standing and when the ambulatory monitoring day was considered to be as stressful as usual or more stressful than usual, and not less stressful than usual. Laboratory-field associations of cardiovascular activity depend in part on the congruence of stressfulness and physical activity level in the 2 situations.

  10. Omega-3 Fatty Acid Supplementation Improves Heart Rate Variability in Obese Children

    Directory of Open Access Journals (Sweden)

    Christoph Baumann

    2018-01-01

    Full Text Available Obese children and adolescents are at high risk of developing cardiovascular diseases later in life. We hypothesized that cardiovascular prophylaxis with omega-3 fatty acids could benefit them. In our study, 20 children and adolescents (mean body mass index percentile: 99.1; mean age: 11.0 years underwent two ambulatory 24 h Holter electrocardiography (ECG recordings (before and after at least 3 months of omega-3 fatty acid supplementation. Time domain heart rate variability (HRV and heart rate (HR were examined for these patients. As a control, we used 24 h Holter ECG recordings of 94 nonobese children and adolescents. Time domain HRV parameters, which are indicators of vagal stimulation, were significantly lower in obese patients than in healthy controls, but HR was higher (standard deviation of the normal-to-normal [SDNN] interbeat intervals: −34.02%; root mean square of successive differences [RMSSD] between normal heartbeats: −40.66%; percentage of consecutive RR intervals [pNN50]: −60.24%; HR: +13.37%. After omega-3 fatty acid supplementation, time domain HRV parameters and HR of obese patients were similar to the values of healthy controls (SDNN interbeat intervals: −21.73%; RMSSD: −19.56%; pNN50: −25.59%; HR: +3.94%. Therefore, omega-3 fatty acid supplementation may be used for cardiovascular prophylaxis in obese children and adolescents.

  11. Reproducibility for Heart Rate Variability Analysis during 6-Min Walk Test in Patients with Heart Failure and Agreement between Devices.

    Science.gov (United States)

    Braga, Lays Magalhães; Prado, Gustavo Faibischew; Umeda, Iracema Ioco Kikuchi; Kawauchi, Tatiana Satie; Taboada, Adriana Marques Fróes; Azevedo, Raymundo Soares; Pereira Filho, Horacio Gomes; Grupi, César José; Souza, Hayala Cristina Cavenague; Moreira, Dalmo Antônio Ribeiro; Nakagawa, Naomi Kondo

    2016-01-01

    Heart rate variability (HRV) analysis is a useful method to assess abnormal functioning in the autonomic nervous system and to predict cardiac events in patients with heart failure (HF). HRV measurements with heart rate monitors have been validated with an electrocardiograph in healthy subjects but not in patients with HF. We explored the reproducibility of HRV in two consecutive six-minute walk tests (6MW), 60-minute apart, using a heart rate monitor (PolarS810i) and a portable electrocardiograph (called Holter) in 50 HF patients (mean age 59 years, NYHA II, left ventricular ejection fraction ~35%). The reproducibility for each device was analysed using a paired t-test or the Wilcoxon signed-rank test. Additionally, we assessed the agreement between the two devices based on the HRV indices at rest, during the 6MW and during recovery using concordance correlation coefficients (CCC), 95% confidence intervals and Bland-Altman plots. The test-retest for the HRV analyses was reproducible using Holter and PolarS810i at rest but not during recovery. In the second 6MW, patients showed significant increases in rMSSD and walking distance. The PolarS810i measurements had remarkably high concordance correlation [0.86rates, a small effect in increasing differences between Holter and Polar in R-R intervals was observed. In conclusion, our study showed good reproducibility of HRV at rest in two consecutive 6MW using Holter and PolarS810i. Additionally, PolarS810i produced good agreements in short-term HRV indices based on Holter simultaneous recordings at rest, during the 6MW and recovery in HF patients.

  12. Bluetooth Heart Rate Monitors For Spaceflight

    Science.gov (United States)

    Buxton, R. E.; West, M. R.; Kalogera, K. L.; Hanson, A. M.

    2016-01-01

    Heart rate monitoring is required for crewmembers during exercise aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data are required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health aboard the ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) were worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_HRM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the 2 data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. RESULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6% error), followed by CS4 (3.3% error), CS3 (6.4% error), and CS2 (9.2% error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, but unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to obtain the best quality data. CS2 will be

  13. Intrapartum fetal heart rate profiles with and without fetal asphyxia.

    Science.gov (United States)

    Low, J A; Pancham, S R; Worthington, D N

    1977-04-01

    Fetal heart rate profiles for periods up to 12 hours prior to delivery have been reviewed in 515 patients with a fetus at risk. Mechanisms other than fetal asphyxia will cause fetal heart rate decelerations, and fetal asphyxia may in some instances develop in the absence of total or late decelerations. However, an increasing incidence of total decelerations and late decelerations and particularly a marked pattern of total decelerations and late decelerations are of value in the prediction of fetal asphyxia. Fetal heart rate deceleration patterns can predict the probability of fetal asphyxia at the time of initial intervention, while a progression of fetal heart rate deceleration patterns in the individual fetus can be of assistance in the subsequent scheduling of serial acid-base assessments during labor.

  14. Effects of electromagnetic radiation (bright light, extremely low-frequency magnetic fields, infrared radiation) on the circadian rhythm of melatonin synthesis, rectal temperature, and heart rate.

    Science.gov (United States)

    Griefahn, Barbara; Künemund, Christa; Blaszkewicz, Meinolf; Lerchl, Alexander; Degen, Gisela H

    2002-10-01

    Electromagnetic spectra reduce melatonin production and delay the nadirs of rectal temperature and heart rate. Seven healthy men (16-22 yrs) completed 4 permuted sessions. The control session consisted of a 24-hours bedrest at infrared radiation (65 degrees C) was applied from 5 pm to 1 am. Salivary melatonin level was determined hourly, rectal temperature and heart rate were continuously recorded. Melatonin synthesis was completely suppressed by light but resumed thereafter. The nadirs of rectal temperature and heart rate were delayed. The magnetic field had no effect. Infrared radiation elevated rectal temperature and heart rate. Only bright light affected the circadian rhythms of melatonin synthesis, rectal temperature, and heart rate, however, differently thus causing a dissociation, which might enhance the adverse effects of shiftwork in the long run.

  15. Effects of heart rate on myocardial thallium-201 uptake and clearance

    International Nuclear Information System (INIS)

    Nordrehaug, J.E.; Danielsen, R.; Vik-Mo, H.

    1989-01-01

    The effects of heart rate on the myocardial uptake and clearance of 201 Tl were studied prospectively in seven healthy men, mean age 43 +/- 7 (s.d.) yr. Initial and delayed (3 hr) thallium images were obtained in three views after three bicycle exercise tests: to maximal, 80% and 60% of predicted maximal heart rate. The mean of three views initial myocardial 201 Tl uptake was higher at maximal than at both 80% and 60% of predicted maximal heart rate, being 81% (p less than 0.01) and 60% (p less than 0.01) of maximal activity, respectively. The myocardial activity in the delayed images was identical. There was a linear relationship between heart rate and the initial myocardial activity, r = 0.86 (p less than 0.001). The mean (range) 201 Tl clearance was 58% (51-65), 47% (34-56), and 34% (22-49) (all differences p less than 0.01), respectively. Concordance among the three individual views in estimating clearance was best for the highest exercise level. There was a linear relationship between heart rate and clearance, r = 0.80 (p less than 0.001). Clearance was altered by only 1.67 x 10%/heart bpm (0.024 hr/heart beat). Clearance in the liver, spleen and lungs increased at submaximal exercise levels. Thus, a linear relationship between heart rate and clearance is the result of changes in the initial exercise myocardial 201 Tl activity. Submaximal exercise may reduce reproducibility of clearance estimation, and the change of myocardial clearance with heart rate seems less than previously suggested

  16. Validation of the Nonin 8600V Pulse Oximeter for heart rate and oxygen saturation measurements in rats.

    Science.gov (United States)

    Bernard, Susan L; An, Dowon; Glenny, Robb W

    2004-05-01

    This report validates the use and limitations of the Nonin Pulse Oximeter for measuring heart rate and oxygen saturation in rats. Eight anesthetized Sprague-Dawley rats were intubated and catheterized. Oxygen saturation was directly measured from arterial blood by using a Radiometer OSM3 Hemoximeter adjusted for rat blood as well as indirectly by using the Nonin Pulse Oximeter. Oxygen saturation was changed by varying the level of inhaled oxygen. Heart rate was measured in two ways: 1) by using the signal from the Nonin Pulse Oximeter and 2) by counting the pressure pulses from the transduced blood pressure. There was excellent agreement between heart rate values measured by the Nonin Pulse Oximeter and that measured by counting the pulses from the arterial blood pressure recording. The Nonin Pulse Oximeter underestimated oxygen saturations by about 3% to 5% compared to the Hemoximeter. Overall, the pulse oximeter reflected important trends in oxygen saturations, making it a useful tool for laboratory animal medicine.

  17. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability

    OpenAIRE

    E.R. Migliaro; P. Contreras; S. Bech; A. Etxagibel; M. Castro; R. Ricca; K. Vicente

    2001-01-01

    In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-...

  18. Day-to-Day Heart-Rate Variability Recordings in World-Champion Rowers: Appreciating Unique Athlete Characteristics.

    Science.gov (United States)

    Plews, Daniel J; Laursen, Paul B; Buchheit, Martin

    2017-05-01

    Heart-rate variability (HRV) is a popular tool for monitoring autonomic nervous system status and training adaptation in athletes. It is believed that increases in HRV indicate effective training adaptation, but these are not always apparent in elite athletes. Resting HRV was recorded in 4 elite rowers (rowers A, B, C, and D) over the 7-wk period before their success at the 2015 World Rowing Championships. The natural logarithm of the square root of the mean sum of the squared differences (Ln rMSSD) between R-R intervals, Ln rMSSD:R-R ratio trends, and the Ln-rMSSD-to-R-R-interval relationship were assessed for each championship-winning rower. The time course of change in Ln rMSSD was athlete-dependent, with stagnation and decreases apparent. However, there were consistent substantial reductions in the Ln rMSSD:R-R ratio: rower A, baseline toward wk 5 (-2.35 ± 1.94); rower B, baseline to wk 4 and 5 (-0.41 ± 0.48 and -0.64 ± 0.65, respectively); rower C, baseline to wk 4 (-0.58 ± 0.66); and rower D, baseline to wk 4, 5, and 6 (-1.15 ± 0.91, -0.81 ± 0.74, and -1.43 ± 0.69, respectively). Reductions in Ln rMSSD concurrent with reductions in the Ln rMSSD:R-R ratio are indicative of parasympathetic saturation. Consequently, 3 of 4 rowers displayed substantial increases in parasympathetic activity despite having decreases in Ln rMSSD. These results confirm that a combination of indices should be used to monitor cardiac autonomic activity.

  19. Heart rate, multiple body temperature, long-range and long-life telemetry system for free-ranging animals

    Science.gov (United States)

    Lund, G. F.; Westbrook, R. M.; Fryer, T. B.

    1980-01-01

    The design details and rationale for a versatile, long-range, long-life telemetry data acquisition system for heart rates and body temperatures at multiple locations from free-ranging animals are presented. The design comprises an implantable transmitter for short to medium range transmission, a receiver retransmitter collar to be worn for long-range transmission, and a signal conditioner interface circuit to assist in signal discrimination and demodulation of receiver or tape-recorded audio outputs. Implanted electrodes are used to obtain an ECG, from which R-wave characteristics are selected to trigger a short RF pulse. Pulses carrying heart rate information are interrupted periodically by a series of pulse interval modulated RF pulses conveying temperature information sensed at desired locations by thermistors. Pulse duration and pulse sequencing are used to discriminate between heart rate and temperature pulses as well as radio frequency interference. The implanted transmitter may be used alone for medium and short-range tracking, or with a receiver-transmitter collar that employs commercial tracking equipment for transmissions of up to 12 km. A system prototype has been tested on a dog.

  20. Using Complexity Metrics With R-R Intervals and BPM Heart Rate Measures

    DEFF Research Database (Denmark)

    Wallot, Sebastian; Fusaroli, Riccardo; Tylén, Kristian

    2013-01-01

    Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker of inter......Lately, growing attention in the health sciences has been paid to the dynamics of heart rate as indicator of impending failures and for prognoses. Likewise, in social and cognitive sciences, heart rate is increasingly employed as a measure of arousal, emotional engagement and as a marker...... of interpersonal coordination. However, there is no consensus about which measurements and analytical tools are most appropriate in mapping the temporal dynamics of heart rate and quite different metrics are reported in the literature. As complexity metrics of heart rate variability depend critically...

  1. Heart rate variability in newborns.

    Science.gov (United States)

    Javorka, K; Lehotska, Z; Kozar, M; Uhrikova, Z; Kolarovszki, B; Javorka, M; Zibolen, M

    2017-09-22

    Heart rate (HR) and heart rate variability (HRV) in newborns is influenced by genetic determinants, gestational and postnatal age, and other variables. Premature infants have a reduced HRV. In neonatal HRV evaluated by spectral analysis, a dominant activity can be found in low frequency (LF) band (combined parasympathetic and sympathetic component). During the first postnatal days the activity in the high frequency (HF) band (parasympathetic component) rises, together with an increase in LF band and total HRV. Hypotrophy in newborn can cause less mature autonomic cardiac control with a higher contribution of sympathetic activity to HRV as demonstrated by sequence plot analysis. During quiet sleep (QS) in newborns HF oscillations increase - a phenomenon less expressed or missing in premature infants. In active sleep (AS), HRV is enhanced in contrast to reduced activity in HF band due to the rise of spectral activity in LF band. Comparison of the HR and HRV in newborns born by physiological vaginal delivery, without (VD) and with epidural anesthesia (EDA) and via sectio cesarea (SC) showed no significant differences in HR and in HRV time domain parameters. Analysis in the frequency domain revealed, that the lowest sympathetic activity in chronotropic cardiac chronotropic regulation is in the VD group. Different neonatal pathological states can be associated with a reduction of HRV and an improvement in the health conditions is followed by changes in HRV what can be use as a possible prognostic marker. Examination of heart rate variability in neonatology can provide information on the maturity of the cardiac chronotropic regulation in early postnatal life, on postnatal adaptation and in pathological conditions about the potential dysregulation of cardiac function in newborns, especially in preterm infants.

  2. Combined effect of whole-body vibration and ambient lighting on human discomfort, heart rate, and reaction time.

    Science.gov (United States)

    Monazzam, Mohammad Reza; Shoja, Esmaeil; Zakerian, Seyed Abolfazl; Foroushani, Abbas Rahimi; Shoja, Mohsen; Gharaee, Masoumeh; Asgari, Amin

    2018-03-12

    This study aimed to investigate the effect of whole-body vibration and ambient lighting, as well as their combined effect on human discomfort, heart rate, and reaction time in laboratory conditions. 44 men were recruited with an average age of 25.4 ± 1.9 years. Each participant was subjected to 12 experimental steps, each step lasting five minutes for four different vibration accelerations in X, Y, and Z axes at a fixed frequency; three different lighting intensities of 50, 500, and 1000 lx were also considered. At each step, a visual computerized reaction test was taken from subjects and their heart rate recorded by pulse oximeter. In addition, the discomfort rate of subjects was measured using Borg scale. Increasing vibration acceleration significantly increased the discomfort rate and heart beat but not the reaction time. Lack of lighting caused more discomfort in the subjects, but there was no significant correlation between lighting intensity with heart rate and reaction time. The results also showed that the combined effect of vibration and lighting had no significant effect on any of the discomfort, heart rate, and reaction time variables. Whole-body vibration is an important factor in the development of human subjective and physiological reactions compared to lighting. Therefore, consideration of the level of vibration to which an individual is exposed in workplaces subject to vibration plays an important role in reducing the level of human discomfort, but its interaction with ambient lighting does not have a significant effect on human subjective and physiological responses.

  3. Quantification of fetal heart rate regularity using symbolic dynamics

    Science.gov (United States)

    van Leeuwen, P.; Cysarz, D.; Lange, S.; Geue, D.; Groenemeyer, D.

    2007-03-01

    Fetal heart rate complexity was examined on the basis of RR interval time series obtained in the second and third trimester of pregnancy. In each fetal RR interval time series, short term beat-to-beat heart rate changes were coded in 8bit binary sequences. Redundancies of the 28 different binary patterns were reduced by two different procedures. The complexity of these sequences was quantified using the approximate entropy (ApEn), resulting in discrete ApEn values which were used for classifying the sequences into 17 pattern sets. Also, the sequences were grouped into 20 pattern classes with respect to identity after rotation or inversion of the binary value. There was a specific, nonuniform distribution of the sequences in the pattern sets and this differed from the distribution found in surrogate data. In the course of gestation, the number of sequences increased in seven pattern sets, decreased in four and remained unchanged in six. Sequences that occurred less often over time, both regular and irregular, were characterized by patterns reflecting frequent beat-to-beat reversals in heart rate. They were also predominant in the surrogate data, suggesting that these patterns are associated with stochastic heart beat trains. Sequences that occurred more frequently over time were relatively rare in the surrogate data. Some of these sequences had a high degree of regularity and corresponded to prolonged heart rate accelerations or decelerations which may be associated with directed fetal activity or movement or baroreflex activity. Application of the pattern classes revealed that those sequences with a high degree of irregularity correspond to heart rate patterns resulting from complex physiological activity such as fetal breathing movements. The results suggest that the development of the autonomic nervous system and the emergence of fetal behavioral states lead to increases in not only irregular but also regular heart rate patterns. Using symbolic dynamics to

  4. Evoked response of heart rate variability using short-duration white noise.

    Science.gov (United States)

    Lee, Guo-She; Chen, Mei-Ling; Wang, Gin-You

    2010-06-24

    To investigate and to establish a model for evaluation of the instant cardiovascular responses to the noises of low-to-moderate intensity, sixteen healthy subjects were enrolled. The white noises were binaurally presented with a supra-aural earphone. The test intensities of noises were no noise, 50, 60, 70 and 80 dBA. Each noise was continued for 5 min and the electrocardiogram was simultaneously recorded. The cardiac autonomic responses were evaluated using power spectral analysis of the R-R contour obtained from digital signal processing of the ECG tracings. The result showed that the mean heart rate and mean blood pressure did not change significantly with the noises. However, the low-frequency power (LF) which represents cardiac autonomic modulations and the ratio (LHR) of LF to high-frequency power (HF) which reflects cardiac sympathetic modulations were significantly greater in the noise intensity of 50, 60, 70 and 80dBA (pnoise intensity (rho=0.90, pwhite noises can be detected using power spectral analysis of heart rate variability and the evoked responses may provide a sensitive way to evaluate the instant effect of noise to humans.

  5. Diminution of Heart Rate Variability in Bipolar Depression

    Directory of Open Access Journals (Sweden)

    Brandon Hage

    2017-12-01

    Full Text Available Autonomic nervous system (ANS dysregulation in depression is associated with symptoms associated with the ANS. The beat-to-beat pattern of heart rate defined as heart rate variability (HRV provides a noninvasive portal to ANS function and has been proposed to represent a means of quantifying resting vagal tone. We quantified HRV in bipolar depressed (BDD patients as a measure of ANS dysregulation seeking to establish HRV as a potential diagnostic and prognostic biomarker for treatment outcome. Forty-seven BDD patients were enrolled. They were randomized to receive either escitalopram–celecoxib or escitalopram-placebo over 8 weeks in a double-blind study design. Thirty-five patients completed the HRV studies. Thirty-six healthy subjects served as controls. HRV was assessed at pretreatment and end of study and compared with that of controls. HRV was quantified and corrected for artifacts using an algorithm that incorporates time and frequency domains to address non-stationarity of the beat-to-beat heart rate pattern. Baseline high frequency-HRV (i.e., respiratory sinus arrhythmia was lower in BDD patients than controls, although the difference did not reach significance. Baseline low-frequency HRV was significantly lower in BDD patients (ln4.20 than controls (ln = 5.50 (p < 0.01. Baseline heart period was significantly shorter (i.e., faster heart rate in BDD patients than controls. No significant change in HRV parameters were detected over the course of the study with either treatment. These findings suggest that components of HRV may be diminished in BDD patients.

  6. Modeling baroreflex regulation of heart rate during orthostatic stress

    DEFF Research Database (Denmark)

    Olufsen, Mette; Tran, Hien T.; Ottesen, Johnny T.

    2006-01-01

    . The model uses blood pressure measured in the finger as an input to model heart rate dynamics in response to changes in baroreceptor nerve firing rate, sympathetic and parasympathetic responses, vestibulo-sympathetic reflex, and concentrations of norepinephrine and acetylcholine. We formulate an inverse...... in healthy and hypertensive elderly people the hysteresis loop shifts to higher blood pressure values and its area is diminished. Finally, for hypertensive elderly people the hysteresis loop is generally not closed indicating that during postural change from sitting to standing, the blood pressure resettles......During orthostatic stress, arterial and cardiopulmonary baroreflexes play a key role in maintaining arterial pressure by regulating heart rate. This study, presents a mathematical model that can predict the dynamics of heart rate regulation in response to postural change from sitting to standing...

  7. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    Science.gov (United States)

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  8. Relationship between heart rate and preference for tempo of music.

    Science.gov (United States)

    Iwanaga, M

    1995-10-01

    People prefer music with tempi ranging from 70 to 100 cycles per minute similar to that of adults' heart rate within normal daily situations. Previous studies of the relation between preferred tempi and heart rates using a pure tone also have indicated that subjects tended to prefer tempi similar to their heart rates. The present study examined this relationship using a musical piece (the theme of "It's a small world") as a stimulus. 14 undergraduate women were subjects who searched for their favorite tempi by controlling the musical tempo by themselves. The most preferred tempo was close to their cycle of heart beats, however, tempi that were one and a half and twice as fast as the heart rate were less preferred in the present study than in a previous study using a tone. Subjects preferred faster tempi in the descending series of stimuli than in the ascending one, and hence were influenced by the initial value of the tempo in the trial sequence. The effects due to the differences of the meaning of the stimuli are considered.

  9. Comparison of two systems for long-term heart rate variability monitoring in free-living conditions - a pilot study

    DEFF Research Database (Denmark)

    Kristiansen, Jesper; Korshoj, Mette; Skotte, Jorgen H

    2011-01-01

    Actiheart and Holter recorders, and signals were processed to RR-interval time series. Segments of 5-minute duration were sampled every 30 minutes, and spectral components of the heart rate variability were calculated. Actiheart and Holter values were compared using Deming regression analysis and Bland...

  10. Effects of smoking on heart rate at rest and during exercise, and on heart rate recovery, in young adults.

    Science.gov (United States)

    Papathanasiou, George; Georgakopoulos, Dimitris; Papageorgiou, Effie; Zerva, Efthimia; Michalis, Lampros; Kalfakakou, Vasiliki; Evangelou, Angelos

    2013-01-01

    There is an established link between smoking, abnormal heart rate (HR) values, and impaired cardiovascular health in middle-aged or older populations. The purpose of this study was to examine the effects of smoking on resting HR and on HR responses during and after exercise in young adults. A sample of 298 young adults (159 men), aged 20-29 years old, were selected from a large population of health-science students based on health status, body mass index, physical activity, and smoking habit. All subjects underwent a maximal Bruce treadmill test and their HR was recorded during, at peak, and after termination of exercise. Smokers had significantly higher resting HR values than non-smokers. Both female and male smokers showed a significantly slower HR increase during exercise. Female smokers failed to reach their age-predicted maximum HR by 6.0 bpm and males by 3.6 bpm. The actual maximum HR achieved (HRmax) was significantly lower for both female smokers (191.0 bpm vs.198.0 bpm) and male smokers (193.2 bpm vs.199.3 bpm), compared to non-smokers. Heart rate reserve was also significantly lower in female (114.6 bpm vs. 128.1 bpm) and male smokers (120.4 bpm vs. 133.0 bpm). During recovery, the HR decline was significantly attenuated, but only in female smokers. Females had a higher resting HR and showed a higher HR response during sub-maximal exercise compared to males. Smoking was found to affect young smokers' HR, increasing HR at rest, slowing HR increase during exercise and impairing their ability to reach the age-predicted HRmax. In addition, smoking was associated with an attenuated HR decline during recovery, but only in females.

  11. Heart-Rate Recovery Index Is Impaired in Behçet's Disease

    Science.gov (United States)

    Kaya, Ergun Baris; Yorgun, Hikmet; Akdogan, Ali; Ates, Ahmet Hakan; Canpolat, Ugur; Sunman, Hamza; Aytemir, Kudret; Tokgozoglu, Lale; Kabakci, Giray; Calguneri, Meral; Ozkutlu, Hilmi; Oto, Ali

    2009-01-01

    Behçet's disease, a multisystemic inflammatory disorder, has been associated with a number of cardiovascular dysfunctions, including ventricular arrhythmias and sudden cardiac death. Heart-rate recovery after exercise can provide both an estimate of impaired parasympathetic tone and a prognosis in regard to all-cause and cardiovascular death. The aim of our study was to evaluate heart-rate recovery in Behçet's disease From January through July 2008, we examined at our outpatient clinic and prospectively enrolled 30 consecutive patients with Behçet's disease and 50 healthy control participants who were matched for age and sex. Basal electrocardiography, echocardiography, and treadmill exercise testing were performed in all patients and control participants. The heart-rate recovery index was calculated in the usual manner, by subtracting the 1st-minute (Rec1), 2nd-minute (Rec2), and 3rd-minute (Rec3) recovery heart rates from the maximal heart rate after exercise stress testing. Patients with Behçet's disease exhibited significantly lower heart-rate recovery numbers, compared with healthy control participants: Rec1, 24.28 ± 8.2 vs 34.4 ± 7.6, P = 0.002; Rec2, 49.28 ± 11.2 vs 57.5 ± 7.0, P < 0.05; and Rec3, 56.2 ± 12.11 vs 67.4 ± 8.7, P = 0.014. To our knowledge, this is the 1st study that shows an impaired heart-rate recovery index (indicative of reduced parasympathetic activity) among patients with Behçet's disease. Given the independent prognostic value of the heart-rate recovery index, our results may explain the increased occurrence of arrhythmias and sudden cardiac death in Behçet's patients. Therefore, this index may be clinically useful in the identification of high-risk patients. PMID:19693299

  12. Do high fetal catecholamine levels affect heart rate variability and ...

    African Journals Online (AJOL)

    Objectives. To deternrine the relationship between Umbilical arterial catecholamine levels and fetal heart rate variability and meconium passage. Study design. A prospective descriptive study was perfonned. Umbilical artery catecholamine levels were measured in 55 newborns and correlated with fetal heart rate before ...

  13. Fetal Heart Rate Monitoring during Labor

    Science.gov (United States)

    ... What are the types of monitoring? • How is auscultation performed? • How is electronic fetal monitoring performed? • How ... methods of fetal heart rate monitoring in labor. Auscultation is a method of periodically listening to the ...

  14. Pharmacokinetic-pharmacodynamic modeling of QRS-prolongation by flecainide: heart rate-dependent effects during sinus rhythm in conscious telemetered dogs.

    Science.gov (United States)

    Sällström, Johan; Al-Saffar, Ahmad; Pehrson, Rikard

    2014-01-01

    The duration of the QRS interval is determined by the ion currents involved in cardiac depolarization. Class I antiarrhythmic drugs reduce cardiac excitability and conduction by inhibiting Nav1.5 channels responsible for I(Na), thus increasing the QRS interval. Previous studies in humans as well as in animal models have demonstrated a more pronounced effect on QRS-prolongation during higher heart rates. In the present study, the effects of the Nav1.5 inhibitor flecainide on cardiovascular parameters, were studied in the telemetered beagle dog under normal autonomic control. The heart rate dependency of QRS prolongation was characterized using pharmacokinetic-pharmacodynamic (PKPD) modeling. Four male telemetered beagle dogs were administered placebo or flecainide (100, 150 and 200 mg) in a Latin square design. The QRS interval and heart rate were recorded, and blood samples were taken. Plasma concentrations of flecainide were fitted to a one compartment oral model and the intrapolated plasma concentrations were fitted to QRS and heart rate data sampled during 5 h after dosing. Flecainide increased the QRS interval in all dogs, whereas there were no effects on heart rate. Using the PKPD model, a statistically significant heart rate-dependent QRS prolongation was linked to individual concentration-time profiles of flecainide. PKPD analysis of QRS interval data from unrestrained dogs with sinus rhythm can elucidate mechanisms previously only described during controlled heart rhythm. Specific questions can therefore be addressed in generically designed cardiovascular telemetry safety studies and different types of relationships between parameters can be uncovered. In addition, the present approach can be used to better characterize drug-induced QRS effects in cardiovascular dog models. © 2013.

  15. Exercise training improves heart rate variability after methamphetamine dependency.

    Science.gov (United States)

    Dolezal, Brett Andrew; Chudzynski, Joy; Dickerson, Daniel; Mooney, Larissa; Rawson, Richard A; Garfinkel, Alan; Cooper, Christopher B

    2014-06-01

    Heart rate variability (HRV) reflects a healthy autonomic nervous system and is increased with physical training. Methamphetamine dependence (MD) causes autonomic dysfunction and diminished HRV. We compared recently abstinent methamphetamine-dependent participants with age-matched, drug-free controls (DF) and also investigated whether HRV can be improved with exercise training in the methamphetamine-dependent participants. In 50 participants (MD = 28; DF = 22), resting heart rate (HR; R-R intervals) was recorded over 5 min while seated using a monitor affixed to a chest strap. Previously reported time domain (SDNN, RMSSD, pNN50) and frequency domain (LFnu, HFnu, LF/HF) parameters of HRV were calculated with customized software. MD were randomized to thrice-weekly exercise training (ME = 14) or equal attention without training (MC = 14) over 8 wk. Groups were compared using paired and unpaired t-tests. Statistical significance was set at P ≤ 0.05. Participant characteristics were matched between groups (mean ± SD): age = 33 ± 6 yr; body mass = 82.7 ± 12 kg, body mass index = 26.8 ± 4.1 kg·min. Compared with DF, the MD group had significantly higher resting HR (P HRV indices were similar between ME and MC groups. However, after training, the ME group significantly (all P HRV, based on several conventional indices, was diminished in recently abstinent, methamphetamine-dependent individuals. Moreover, physical training yielded a marked increase in HRV, representing increased vagal modulation or improved autonomic balance.

  16. [The influence of physical exercise on heart rate variability].

    Science.gov (United States)

    Gajek, Jacek; Zyśko, Dorota; Negrusz-Kawecka, Marta; Halawa, Bogumił

    2003-03-01

    Heart rate variability is controlled by the influence of autonomic nervous system, whereas one part of the system modulates the activity of the other. There is evidence of increased sympathetic activity in patients (pts) with essential hypertension. The aim of the study was to assess the persisting influence of increased sympathetic activity 30 min after moderate physical exercise on heart rate variability in patients with arterial hypertension. The study was performed in 19 patients (10 women, mean age 52.7 +/- 9.5 years and 9 men, mean age 37.7 +/- 8.8 years) with stage I (6 pts) and stage II (13 pts) arterial hypertension. All studied pts had sinus rhythm, were free of diabetes, coronary heart disease and congestive heart failure. 24-hour Holter monitoring was performed and for 30 min before the exercise test the pts stayed in supine rest. The exercise tests were performed between 10 and 11 a.m. Immediately after the exercise all pts stayed in supine position for 30 min. The heart rate variability parameters were studied using Holter monitoring system Medilog Optima Jet and were then analysed statistically. The mean energy expenditure during the exercise was 5.8 +/- 1.1 METs and the maximal heart rate was 148.1 +/- 20.3 bpm. All studied HRV parameters were significantly different in the assessed time period compared to the baseline values (p < 0.001). Significant correlation was found between the age of the studied patients and the mean RR interval, what can be considered as a hyperkinetic (hyperadrenergic) circulatory status and shorter RR interval in younger pts. Significant negative correlation between the age and SDNN parameter (r = -0.65, p < 0.001), 30 min after the exercise mirrors the prolonged adrenergic influence in older pts. The present study shows that the influence of moderate physical exercise on heart rate variability in pts with essential hypertension is extended over 30 min period after exercise and is more pronounced in older pts. The studies

  17. Heart rate variability changes in business process outsourcing employees working in shifts.

    Science.gov (United States)

    Kunikullaya, Kirthana U; Kirthi, Suresh K; Venkatesh, D; Goturu, Jaisri

    2010-10-31

    Irregular and poor quality sleep is common in business process outsourcing (BPO) employees due to continuous shift working. The influence of this on the cardiac autonomic activity was investigated by the spectral analysis of heart rate variability (HRV). 36 night shift BPO employees (working from 22:00 to 06:00h) and 36 age and sex matched day shift BPO employees (working from 08:00 to 16:00h) were recruited for the study. Five minute electrocardiogram (ECG) was recorded in all the subjects. Heart rate variability was analyzed by fast Fourier transformation using RMS Vagus HRV software. The results were analyzed using Mann Whitney U test, Student t-test, Wilcoxon signed rank test and were expressed as mean ± SD. Sleepiness was significantly higher among night shift workers as measured by Epworth Sleepiness Scale (p<0.001). Night shift BPO employees were found to have a trend towards lower values of vagal parameters - HF power (ms(2)), and higher values of sympathovagal parameters like LF Power (ms(2)) and the LF/HF power (%) suggesting decreased vagal activity and sympathetic over activity, when compared to day shift employees. However, HRV parameters did not vary significantly between the day shift employees and night shift workers baseline values, and also within the night shift group. Night shift working increased the heart rate and shifted the sympathovagal balance towards sympathetic dominance and decreased vagal parameters of HRV. This is an indicator of unfavorable change in the myocardial system, and thus shows increased risk of cardiovascular disease among the night shift employees.

  18. [Voluntary alpha-power increasing training impact on the heart rate variability].

    Science.gov (United States)

    Bazanova, O M; Balioz, N V; Muravleva, K B; Skoraia, M V

    2013-01-01

    In order to study the effect of the alpha EEG power increasing training at heart rate variability (HRV) as the index of the autonomic regulation of cognitive functions there were follow tasks: (1) to figure out the impact of biofeedback in the voluntary increasing the power in the individual high-frequency alpha-band effect on heart rate variability and related characteristics of cognitive and emotional spheres, (2) to determine the nature of the relationship between alpha activity indices and heart rate variability, depending on the alpha-frequency EEG pattern at rest (3) to examine how the individual alpha frequency EEG pattern is reflected in changes HRV as a result of biofeedback training. Psychometric indicators of cognitive performance, the characteristics of the alpha-EEG activity and heart rate variability (HRV) as LF/HF and pNN50 were recorded in 27 healthy men aged 18-34 years, before, during, and after 10 sessions of training of voluntary increase in alpha power in the individual high-frequency alpha band with eyes closed. To determine the biofeedback effect on the alpha power increasing training, data subjects are compared in 2 groups: experimental (14) with the real and the control group (13 people)--with mock biofeedback. The follow up effect of trainings was studied through month over the 10 training sessions. Results showed that alpha biofeedback training enhanced the fluency and accuracy in cognitive performance, decreased anxiety and frontal EMG, increased resting frequency, width and power in individual upper alpha range only in participants with low baseline alpha frequency. While mock biofeedback increased resting alpha power only in participants with high baseline resting alpha frequency and did change neither cognitive performance, nor HRV indices. Biofeedback training eliminated the alpha power decrease in response to arithmetic task in both with high and low alpha frequency participants and this effect was followed up over the month. Mock

  19. The use of heart rate turbulence and heart rate variability in the assessment of autonomic regulation and circadian rhythm in patients with systemic lupus erythematosus without apparent heart disease.

    Science.gov (United States)

    Poliwczak, A R; Waszczykowska, E; Dziankowska-Bartkowiak, B; Koziróg, M; Dworniak, K

    2018-03-01

    Background Systemic lupus erythematosus is a progressive autoimmune disease. There are reports suggesting that patients even without overt signs of cardiovascular complications have impaired autonomic function. The aim of this study was to assess autonomic function using heart rate turbulence and heart rate variability parameters indicated in 24-hour ECG Holter monitoring. Methods Twenty-six women with systemic lupus erythematosus and 30 healthy women were included. Twenty-four hour ambulatory ECG-Holter was performed in home conditions. The basic parameters of heart rate turbulence and heart rate variability were calculated. The analyses were performed for the entire day and separately for daytime activity and night time rest. Results There were no statistically significant differences in the basic anthropometric parameters. The mean duration of disease was 11.52 ± 7.42. There was a statistically significant higher turbulence onset (To) value in patients with systemic lupus erythematosus, median To = -0.17% (minimum -1.47, maximum 3.0) versus To = -1.36% (minimum -4.53, maximum -0.41), P lupus erythematosus group than in the healthy controls, including SDANN and r-MSSD and p50NN. Concerning the morning activity and night resting periods, the results were similar as for the whole day. In the control group, higher values in morning activity were noted for parameters that characterise sympathetic activity, especially SDANN, and were significantly lower for parasympathetic parameters, including r-MSSD and p50NN, which prevailed at night. There were no statistically significant changes for systemic lupus erythematosus patients for p50NN and low and very low frequency. There was a positive correlation between disease duration and SDNN, R = 0.417; P < 0.05 and SDANN, R = 0.464; P < 0.05, a negative correlation between low/high frequency ratio and r-MSSD, R = -0.454; P < 0.05; p50NN, R = -0.435; P < 0.05 and high frequency

  20. Correlation of heart rate and radionuclide index of left ventricular contraction and relaxation

    International Nuclear Information System (INIS)

    Adachi, Haruhiko; Sugihara, Hiroki; Nakagawa, Hiroaki; Inagaki, Suetsugu; Kubota, Yasushi; Nakagawa, Masao

    1990-01-01

    Since the cardiac function indices derived from radionuclide ventriculography (RNV) are considered to depend on the heart rate, we studied the relationship between systolic or diastolic indices and heart rates in patients with normal RNV and devised a method of correcting these indices according to the heart rate. For the systolic indices, the heart rate showed significant correlation with ET (r=-0.640), PER (r=0.791) and TPE (r=-0.401) but not with EF, 1/3 EF, MNSER or 1/3 MNSER. For the diastolic indices, the heart rate correlated well with FT (r=-0.938), RFT (r=-0.736), SFT (r=-0.803), 1/3 FF (r=-0.758), PFR (r=0.759), 1/3 PFR (r=0.742) and TPF (r=-0.389) but not with AFT, 1/3 MNDFR or AFF. These results indicate that many systolic and diastolic indices derived from RNV are affected by the heart rate, So when cardiac function is evaluated with the use of radionuclide indices, those which are independent of the heart rate should be used, or they should be corrected for the heart rate. As a method of correction, we proposed a rotating method obtained by manipulation of the regression equation of heart rates and indices. This new method is certain and easier to use when the correcting equations are set into a computer program. (author)

  1. Fractal analysis of heart rate variability and mortality after an acute myocardial infarction

    DEFF Research Database (Denmark)

    Tapanainen, Jari M; Thomsen, Poul Erik Bloch; Køber, Lars

    2002-01-01

    The recently developed fractal analysis of heart rate (HR) variability has been suggested to provide prognostic information about patients with heart failure. This prospective multicenter study was designed to assess the prognostic significance of fractal and traditional HR variability parameters...... in a large, consecutive series of survivors of an acute myocardial infarction (AMI). A consecutive series of 697 patients were recruited to participate 2 to 7 days after an AMI in 3 Nordic university hospitals. The conventional time-domain and spectral parameters and the newer fractal scaling indexes of HR...... variability were analyzed from 24-hour RR interval recordings. During the mean follow-up of 18.4 +/- 6.5 months, 49 patients (7.0%) died. Of all the risk variables, a reduced short-term fractal scaling exponent (alpha(1)

  2. A healthy heart is not a metronome: an integrative review of the heart's anatomy and heart rate variability.

    Science.gov (United States)

    Shaffer, Fred; McCraty, Rollin; Zerr, Christopher L

    2014-01-01

    Heart rate variability (HRV), the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF), very-low-frequency (VLF), low-frequency (LF), and high-frequency (HF) bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges' polyvagal theory, Thayer and colleagues' neurovisceral integration model, Lehrer et al.'s resonance frequency model, and the Institute of HeartMath's coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  3. Heart rate variability in bipolar disorder

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Kessing, Lars Vedel; Munkholm, Klaus

    2017-01-01

    Background Heart rate variability (HRV) has been suggested reduced in bipolar disorder (BD) compared with healthy individuals (HC). This meta-analysis investigated: HRV differences in BD compared with HC, major depressive disorder or schizophrenia; HRV differences between affective states; HRV...

  4. Gas exchange and heart rate in the harbour porpoise, Phocoena phocoena

    DEFF Research Database (Denmark)

    Reed, J.Z.; Chambers, C.; Hunter, C.J.

    2000-01-01

    a comparatively high minute rate of gas exchange. Oxygen consumption under these experimental conditions (247 +/- 13.8 ml O-2. min(-1)) was 1.9- fold higher than predicted by standard scaling relations. These data together with an estimate of the total oxygen stores predicted an aerobic dive limit of 5.4 min......The respiratory physiology, heart rates and metabolic rates of two captive juvenile male harbour porpoises (both 28 kg) were measured using a rapid-response respiratory gas analysis system in the laboratory. Breath-hold durations in the laboratory (12 +/- 0.3 s, mean +/- SEM) were shorter than...... field observations. although a few breath-holds of over 40 s were recorded. The mean percentage time spent submerged was 89 +/- 0.4%. Relative to similarly-sized terrestrial mammals, the respiratory frequency was low (4.9 +/- 0.19 breaths min(-1)) but with high tidal volumes (1.1 +/- 0.01 l), enabling...

  5. Bilateral hegu acupoints have the same effect on the heart rate variability of the healthy subjects.

    Science.gov (United States)

    Guangjun, Wang; Yuying, Tian; Shuyong, Jia; Wenting, Zhou; Weibo, Zhang

    2014-01-01

    Background. The specificity of acupuncture points (acupoints) is one of the key concepts in traditional acupuncture theory, but the question of whether there is adequate scientific evidence to prove or disprove specificity has been vigorously debated in recent years. Acupoint laterality is an important aspect of acupoint specificity. Data is particularly scarce regarding the laterality of the same channel, namesake acupoint located on opposite sides of the body. Our previous study results suggest that Neiguan acupoint (PC6) has the laterality. The aim of this study was to investigate whether Hegu (LI4) also has laterality from the perspective of heart rate variability. Methods. A total of twenty-eight healthy female volunteers were recruited for this study and were randomly separated into the group I (n = 14) and the group II (n = 14) according to the register order. In the group I, left LI4 was stimulated in the first epoch and the right LI4 was stimulated in the second epoch. In the group II, right LI4 was stimulated in the first epoch and left LI4 was stimulated in the second epoch. Electrocardiogram was recorded and heart rate variability was analyzed. Results. The results show that there were no significant differences of heart rate variablity between the group I and the group II in the time domain and in the frequency domain. Conclusions. Bilateral Hegu acupoints have the same effect on the heart rate variability of the healthy subjects.

  6. Bilateral Hegu Acupoints Have the Same Effect on the Heart Rate Variability of the Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Wang Guangjun

    2014-01-01

    Full Text Available Background. The specificity of acupuncture points (acupoints is one of the key concepts in traditional acupuncture theory, but the question of whether there is adequate scientific evidence to prove or disprove specificity has been vigorously debated in recent years. Acupoint laterality is an important aspect of acupoint specificity. Data is particularly scarce regarding the laterality of the same channel, namesake acupoint located on opposite sides of the body. Our previous study results suggest that Neiguan acupoint (PC6 has the laterality. The aim of this study was to investigate whether Hegu (LI4 also has laterality from the perspective of heart rate variability. Methods. A total of twenty-eight healthy female volunteers were recruited for this study and were randomly separated into the group I (n=14 and the group II (n=14 according to the register order. In the group I, left LI4 was stimulated in the first epoch and the right LI4 was stimulated in the second epoch. In the group II, right LI4 was stimulated in the first epoch and left LI4 was stimulated in the second epoch. Electrocardiogram was recorded and heart rate variability was analyzed. Results. The results show that there were no significant differences of heart rate variablity between the group I and the group II in the time domain and in the frequency domain. Conclusions. Bilateral Hegu acupoints have the same effect on the heart rate variability of the healthy subjects.

  7. Heart Rate Variability Interventions for Concussion and Rehabilitation

    Directory of Open Access Journals (Sweden)

    Robert Lake Conder

    2014-08-01

    Full Text Available The study of Heart Rate Variability (HRV has emerged as an essential component of cardiovascular health, as well as a physiological mechanism by which one can increase the interactive communication between the cardiac and the neurocognitive systems (i.e., the body and the brain. It is well-established that lack of heart rate variability implies cardiopathology, morbidity, reduced quality-of-life, and precipitous mortality. On the positive, optimal heart rate variability has been associated with good cardiovascular health, autonomic nervous system (ANS control, emotional regulation, and enhanced neurocognitive processing. In addition to health benefits, optimal HRV has been shown to improve neurocognitive performance by enhancing focus, visual acuity and readiness, and by promoting emotional regulation needed for peak performance. In concussed athletes and soldiers, concussions not only alter brain connectivity, but also alter cardiac functioning and impair cardiovascular performance upon exertion. Altered sympathetic and parasympathetic balance in the ANS has been postulated as a critical factor in refractory Post Concussive Syndrome (PCS. This article will review both the pathological aspects of reduced heart rate variability on athletic performance, as well as the cardiovascular and cerebrovascular components of concussion and PCS. Additionally, this article will review interventions with HRV biofeedback (HRV BFB training as a promising and underutilized treatment for sports and military-related concussion. Finally, this article will review research and promising case studies pertaining to use of HRV BFB for enhancement of cognition and performance, with applicability to concussion rehabilitation.

  8. The Effect of Heart Rate on the Heart Rate Variability Response to Autonomic Interventions

    Directory of Open Access Journals (Sweden)

    George E Billman

    2013-08-01

    Full Text Available Heart rate variability (HRV, the beat-to-beat variation in either heart rate (HR or heart period (R-R interval, has become a popular clinical and investigational tool to quantify cardiac autonomic regulation. However, it is not widely appreciated that, due to the inverse curvilinear relationship between HR and R-R interval, HR per se can profoundly influence HRV. It is, therefore, critical to correct HRV for the prevailing HR particularly, as HR changes in response to autonomic neural activation or inhibition. The present study evaluated the effects of HR on the HRV response to autonomic interventions that either increased (submaximal exercise, n = 25 or baroreceptor reflex activation, n = 20 or reduced (pharmacological blockade: β-adrenergic receptor, muscarinic receptor antagonists alone and in combination, n = 25, or bilateral cervical vagotomy, n = 9 autonomic neural activity in a canine model. Both total (RR interval standard deviation, RRSD and the high frequency variability (HF, 0.2 to 1.04 Hz were determined before and in response to an autonomic intervention. All interventions that reduced or abolished cardiac parasympathetic regulation provoked large reductions in HRV even after HR correction [division by mean RRsec or (mean RRsec2 for RRSD and HF, respectively] while interventions that reduced HR yielded mixed results. β-adrenergic receptor blockade reduced HRV (RRSD but not HF while both RRSD and HF increased in response to increases in arterial blood (baroreceptor reflex activation even after HR correction. These data suggest that the physiological basis for HRV is revealed after correction for prevailing HR and, further, that cardiac parasympathetic activity is responsible for a major portion of the HRV in the dog.

  9. Novel Fingertip Image-Based Heart Rate Detection Methods for a Smartphone

    Directory of Open Access Journals (Sweden)

    Rifat Zaman

    2017-02-01

    Full Text Available We hypothesize that our fingertip image-based heart rate detection methods using smartphone reliably detect the heart rhythm and rate of subjects. We propose fingertip curve line movement-based and fingertip image intensity-based detection methods, which both use the movement of successive fingertip images obtained from smartphone cameras. To investigate the performance of the proposed methods, heart rhythm and rate of the proposed methods are compared to those of the conventional method, which is based on average image pixel intensity. Using a smartphone, we collected 120 s pulsatile time series data from each recruited subject. The results show that the proposed fingertip curve line movement-based method detects heart rate with a maximum deviation of 0.0832 Hz and 0.124 Hz using time- and frequency-domain based estimation, respectively, compared to the conventional method. Moreover, another proposed fingertip image intensity-based method detects heart rate with a maximum deviation of 0.125 Hz and 0.03 Hz using time- and frequency-based estimation, respectively.

  10. Clinical significance of power spectral analysis of heart rate variability and {sup 123}I-metaiodobenzylguanidine (MIBG) myocardial imaging for assessing the severity of heart failure

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Fukuoka, Shuji; Shimotsu, Yoriko; Sasaki, Tatsuya; Kamakura, Shiro; Yasumura, Yoshio; Miyatake, Kunio; Shimomura, Katsuro [National Cardiovascular Center, Suita, Osaka (Japan); Tani, Akihiro

    1997-04-01

    The significance of power spectral analysis of heart rate variability and of MIBG myocardial imaging to see the sympathetic nervous function was evaluated in patients with congestive heart failure due to dilated cardiomyopathy. Subjects were 10 normal volunteers and 8 patients with severity NYHA II; 10 normals and 25 patients with NYHA II and III; and 17 patients treated with a beta-blocker (metoprolol 5-40 mg). ECG was recorded with a portable ECG recorder for measuring RR intervals for 24 hr, which were applied for power spectral analysis. Early and delayed imagings with 111 MBq of {sup 123}I-MIBG were performed at 15 min and 4 hr, respectively, after its intravenous administration for acquisition of anterior planar and SPECT images. Myocardial blood flow SPECT was also done with 111 MBq of {sup 201}Tl given intravenously, and difference of total defect scores between MIBG and Tl images was computed. MIBG myocardial sympathetic nerve imaging in those patients was found useful to assess the severity of heart failure, to predict the risk patients for beta-blocker treatment and to assess the risk in complicated ventricular tachycardia. (K.H.)

  11. Patterns of Interspecific Variation in the Heart Rates of Embryonic Reptiles

    Science.gov (United States)

    Du, Wei-Guo; Ye, Hua; Zhao, Bo; Pizzatto, Ligia; Ji, Xiang; Shine, Richard

    2011-01-01

    New non-invasive technologies allow direct measurement of heart rates (and thus, developmental rates) of embryos. We applied these methods to a diverse array of oviparous reptiles (24 species of lizards, 18 snakes, 11 turtles, 1 crocodilian), to identify general influences on cardiac rates during embryogenesis. Heart rates increased with ambient temperature in all lineages, but (at the same temperature) were faster in lizards and turtles than in snakes and crocodilians. We analysed these data within a phylogenetic framework. Embryonic heart rates were faster in species with smaller adult sizes, smaller egg sizes, and shorter incubation periods. Phylogenetic changes in heart rates were negatively correlated with concurrent changes in adult body mass and residual incubation period among the lizards, snakes (especially within pythons) and crocodilians. The total number of embryonic heart beats between oviposition and hatching was lower in squamates than in turtles or the crocodilian. Within squamates, embryonic iguanians and gekkonids required more heartbeats to complete development than did embryos of the other squamate families that we tested. These differences plausibly reflect phylogenetic divergence in the proportion of embryogenesis completed before versus after laying. PMID:22174948

  12. Heart Rate Monitor for Portable MP3 Player.

    Science.gov (United States)

    Kim, Jaywoo; Lee, Mi-Hee; Lee, Hyoung-Ki; Choi, Kiwan; Bang, Seokwon; Kim, Sangryong

    2005-01-01

    This paper presents a photoplethysmography sensor based on a heart rate monitor for a portable MP3 player. Two major design issues are addressed: one is to acquire the sensor signal with a proper amplitude despite a wide range of variation and the other is to handle the noise contaminated signal which is caused by a motion artifact. A benchmarking test with a professional medical photoplethysmography sensor shows that our device performs very well in calculating heart rate even though our photoplethysmography sensor module was designed to be cost effective.

  13. iHeartLift: a closed loop system with bio-feedback that uses music tempo variability to improve heart rate variability.

    Science.gov (United States)

    Ho, Thomas C T; Chen, Xiang

    2011-01-01

    "Musica delenit bestiam feram" translates into "Music soothes the savage beast". There is a hidden truth in this ancient quip passed down from generations. Besides soothing the heart, it also incites the heart to a healthier level of heart rate variability (HRV). In this paper, an approach to use and test music and biofeedback to increase the heart rate variability for people facing daily stress is discussed. By determining the music tempo variability (MTV) of a piece of music and current heart rate variability, iHeartLift is able to compare the 2 trends and locate a musical piece that is suited to increase the user's heart rate variability to a healthier level. With biofeedback, the 2 trends are continuously compared in real-time and the musical piece is changed in accordance with the current comparisons. A study was conducted and it was generally found that HRV can be uplifted by music regardless of language and meaning of musical lyrics but with limitations to musical genre.

  14. Heart rate variability and baroreflex sensitivity in bilateral lung transplant recipients.

    Science.gov (United States)

    Fontolliet, Timothée; Gianella, Pietro; Pichot, Vincent; Barthélémy, Jean-Claude; Gasche-Soccal, Paola; Ferretti, Guido; Lador, Frédéric

    2018-01-09

    The effects of lung afferents denervation on cardiovascular regulation can be assessed on bilateral lung transplantation patients. The high-frequency component of heart rate variability is known to be synchronous with breathing frequency. Then, if heart beat is neurally modulated by breathing frequency, we may expect disappearance of high frequency of heart rate variability in bilateral lung transplantation patients. On 11 patients and 11 matching healthy controls, we measured R-R interval (electrocardiography), blood pressure (Portapres ® ) and breathing frequency (ultrasonic device) in supine rest, during 10-min free breathing, 10-min cadenced breathing (0·25 Hz) and 5-min handgrip. We analysed heart rate variability and spontaneous variability of arterial blood pressure, by power spectral analysis, and baroreflex sensitivity, by the sequence method. Concerning heart rate variability, with respect to controls, transplant recipients had lower total power and lower low- and high-frequency power. The low-frequency/high-frequency ratio was higher. Concerning systolic, diastolic and mean arterial pressure variability, transplant recipients had lower total power (only for cadenced breathing), low frequency and low-frequency/high-frequency ratio during free and cadenced breathing. Baroreflex sensitivity was decreased. Denervated lungs induced strong heart rate variability reduction. The higher low-frequency/high-frequency ratio suggested that the total power drop was mostly due to high frequency. These results support the hypothesis that neural modulation from lung afferents contributes to the high frequency of heart rate variability. © 2018 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  15. Automated signal quality assessment of mobile phone-recorded heart sound signals.

    Science.gov (United States)

    Springer, David B; Brennan, Thomas; Ntusi, Ntobeko; Abdelrahman, Hassan Y; Zühlke, Liesl J; Mayosi, Bongani M; Tarassenko, Lionel; Clifford, Gari D

    Mobile phones, due to their audio processing capabilities, have the potential to facilitate the diagnosis of heart disease through automated auscultation. However, such a platform is likely to be used by non-experts, and hence, it is essential that such a device is able to automatically differentiate poor quality from diagnostically useful recordings since non-experts are more likely to make poor-quality recordings. This paper investigates the automated signal quality assessment of heart sound recordings performed using both mobile phone-based and commercial medical-grade electronic stethoscopes. The recordings, each 60 s long, were taken from 151 random adult individuals with varying diagnoses referred to a cardiac clinic and were professionally annotated by five experts. A mean voting procedure was used to compute a final quality label for each recording. Nine signal quality indices were defined and calculated for each recording. A logistic regression model for classifying binary quality was then trained and tested. The inter-rater agreement level for the stethoscope and mobile phone recordings was measured using Conger's kappa for multiclass sets and found to be 0.24 and 0.54, respectively. One-third of all the mobile phone-recorded phonocardiogram (PCG) signals were found to be of sufficient quality for analysis. The classifier was able to distinguish good- and poor-quality mobile phone recordings with 82.2% accuracy, and those made with the electronic stethoscope with an accuracy of 86.5%. We conclude that our classification approach provides a mechanism for substantially improving auscultation recordings by non-experts. This work is the first systematic evaluation of a PCG signal quality classification algorithm (using a separate test dataset) and assessment of the quality of PCG recordings captured by non-experts, using both a medical-grade digital stethoscope and a mobile phone.

  16. [Corrective effect of aromatherapy on indices of heart rate variability in students under exam stress conditions].

    Science.gov (United States)

    Abrahamyan, H T; Minasyan, S M

    2016-01-01

    There were investigated changes in indices of the activity of regulatory mechanisms of heart rhythm in student under exam stress conditions and the possibility of their correction with aid of aromatherapy. The examination stress was established to be accompanied by pronounced shifts of integral and spectral indices of heart rhythm in students, indicating to the activation of the sympathetic circuit of Autonomic Nervous System in conditions of examination stress. A positive, relaxation impact of the essential oil of orange on the investigated indices was also recorded. The latter is expressed by weakly pronounced changes or lack of them in data of integral and spectral heart rate indices in students from the experimental group, that indicates to the stabilizing effect of used ethereal oil on the psycho-physiological state of students in conditions of exam stress

  17. Elevated resting heart rate, physical fitness and all-cause mortality

    DEFF Research Database (Denmark)

    Jensen, Magnus Thorsten; Suadicani, Poul; Hein, Hans Ole

    2013-01-01

    To examine whether elevated resting heart rate (RHR) is an independent risk factor for mortality or a mere marker of physical fitness (VO2Max).......To examine whether elevated resting heart rate (RHR) is an independent risk factor for mortality or a mere marker of physical fitness (VO2Max)....

  18. Validity of the Elite HRV Smartphone Application for Examining Heart Rate Variability in a Field-Based Setting.

    Science.gov (United States)

    Perrotta, Andrew S; Jeklin, Andrew T; Hives, Ben A; Meanwell, Leah E; Warburton, Darren E R

    2017-08-01

    Perrotta, AS, Jeklin, AT, Hives, BA, Meanwell, LE, and Warburton, DER. Validity of the elite HRV smartphone application for examining heart rate variability in a field-based setting. J Strength Cond Res 31(8): 2296-2302, 2017-The introduction of smartphone applications has allowed athletes and practitioners to record and store R-R intervals on smartphones for immediate heart rate variability (HRV) analysis. This user-friendly option should be validated in the effort to provide practitioners confidence when monitoring their athletes before implementing such equipment. The objective of this investigation was to examine the relationship and validity between a vagal-related HRV index, rMSSD, when derived from a smartphone application accessible with most operating systems against a frequently used computer software program, Kubios HRV 2.2. R-R intervals were recorded immediately upon awakening over 14 consecutive days using the Elite HRV smartphone application. R-R recordings were then exported into Kubios HRV 2.2 for analysis. The relationship and levels of agreement between rMSSDln derived from Elite HRV and Kubios HRV 2.2 was examined using a Pearson product-moment correlation and a Bland-Altman Plot. An extremely large relationship was identified (r = 0.92; p smartphone HRV application may offer a reliable platform when assessing parasympathetic modulation.

  19. Target Heart Rates

    Science.gov (United States)

    ... Check Recipe Certification Program Nutrition Requirements Heart-Check Professional Resources Contact the Heart-Check Certification Program Simple Cooking and Recipes Dining Out Choosing a Restaurant Deciphering ...

  20. Poincare indices for analyzing meditative heart rate signals

    Directory of Open Access Journals (Sweden)

    Atefeh Goshvarpour

    2015-06-01

    Full Text Available Background: Poincare plots are commonly used to study the nonlinear behavior of physiologic signals. The aim of this study is to evaluate the Poincare plot indices of human heart rate signals during meditation. Methods: For this purpose, heart rate time series of eight Chi meditators available in Physionet database were used. Poincare plots with lags of 1 and 6 were constructed, and the ratio of the minor axis to major axis (SD1/SD2 and the area of Poincare plots were calculated for each lag. Results: The results show that the SD1/SD2 ratio increased significantly during meditation compared to that before meditation, especially the index measured from Poincare plots reconstructed with a lag of 6 (p < 0.05. In addition, in both lags, the area of Poincare plots decreased significantly during meditation compared to before meditation (p < 0.05. Conclusion: The comparative dynamic measures of the Poincare plot indices during and before meditation give more insight of the heart rate signals in a specific psychophysiological state.

  1. The Performance of Short-Term Heart Rate Variability in the Detection of Congestive Heart Failure

    Directory of Open Access Journals (Sweden)

    Fausto Lucena

    2016-01-01

    Full Text Available Congestive heart failure (CHF is a cardiac disease associated with the decreasing capacity of the cardiac output. It has been shown that the CHF is the main cause of the cardiac death around the world. Some works proposed to discriminate CHF subjects from healthy subjects using either electrocardiogram (ECG or heart rate variability (HRV from long-term recordings. In this work, we propose an alternative framework to discriminate CHF from healthy subjects by using HRV short-term intervals based on 256 RR continuous samples. Our framework uses a matching pursuit algorithm based on Gabor functions. From the selected Gabor functions, we derived a set of features that are inputted into a hybrid framework which uses a genetic algorithm and k-nearest neighbour classifier to select a subset of features that has the best classification performance. The performance of the framework is analyzed using both Fantasia and CHF database from Physionet archives which are, respectively, composed of 40 healthy volunteers and 29 subjects. From a set of nonstandard 16 features, the proposed framework reaches an overall accuracy of 100% with five features. Our results suggest that the application of hybrid frameworks whose classifier algorithms are based on genetic algorithms has outperformed well-known classifier methods.

  2. Short- and long-term variations in non-linear dynamics of heart rate variability

    DEFF Research Database (Denmark)

    Kanters, J K; Højgaard, M V; Agner, E

    1996-01-01

    OBJECTIVES: The purpose of the study was to investigate the short- and long-term variations in the non-linear dynamics of heart rate variability, and to determine the relationships between conventional time and frequency domain methods and the newer non-linear methods of characterizing heart rate...... rate and describes mainly linear correlations. Non-linear predictability is correlated with heart rate variability measured as the standard deviation of the R-R intervals and the respiratory activity expressed as power of the high-frequency band. The dynamics of heart rate variability changes suddenly...

  3. An Overview of Heart Rate Variability Metrics and Norms

    Directory of Open Access Journals (Sweden)

    Fred Shaffer

    2017-09-01

    Full Text Available Healthy biological systems exhibit complex patterns of variability that can be described by mathematical chaos. Heart rate variability (HRV consists of changes in the time intervals between consecutive heartbeats called interbeat intervals (IBIs. A healthy heart is not a metronome. The oscillations of a healthy heart are complex and constantly changing, which allow the cardiovascular system to rapidly adjust to sudden physical and psychological challenges to homeostasis. This article briefly reviews current perspectives on the mechanisms that generate 24 h, short-term (~5 min, and ultra-short-term (<5 min HRV, the importance of HRV, and its implications for health and performance. The authors provide an overview of widely-used HRV time-domain, frequency-domain, and non-linear metrics. Time-domain indices quantify the amount of HRV observed during monitoring periods that may range from ~2 min to 24 h. Frequency-domain values calculate the absolute or relative amount of signal energy within component bands. Non-linear measurements quantify the unpredictability and complexity of a series of IBIs. The authors survey published normative values for clinical, healthy, and optimal performance populations. They stress the importance of measurement context, including recording period length, subject age, and sex, on baseline HRV values. They caution that 24 h, short-term, and ultra-short-term normative values are not interchangeable. They encourage professionals to supplement published norms with findings from their own specialized populations. Finally, the authors provide an overview of HRV assessment strategies for clinical and optimal performance interventions.

  4. The 30-second rule: the effects of prolonged intubation attempts on oxygen saturation and heart rate in preterm infants in the delivery room.

    Science.gov (United States)

    Wozniak, Madeline; Arnell, Kathy; Brown, Melissa; Gonzales, Sarah; Lazarus, Danielle; Rich, Wade; Katheria, Anup

    2018-04-01

    A duration of 30 seconds has been shown to improve the success rate of intubation attempts without any decompensation. There is limited data regarding the detrimental effects of prolonged intubation attempts in preterm infants. The aim was to determine the effect of prolonged intubation attempts on heart rate and oxygen saturation in preterm infants. We retrospectively reviewed videos and physiologic data collected during delivery room (DR) resuscitations. Infants who had a functioning pulse oximeter at the time of intubation in the delivery room were analyzed using video and analog recordings. The duration of the intubation attempt was defined as the time the laryngoscope blade was in the infant's mouth. Prolonged intubations were defined as intubations over 30 seconds. Baseline heart rate and saturations were defined as the heart rate and saturation immediately prior to the intubation attempt. Video recording was used to determine time laryngoscope was in the mouth, what other procedures were performed, and whether there was recovery between attempts. Analog data including heart rate, airway pressure and saturation was also recorded. There were 52 intubation attempts in 28 infants. The median (IQR) birth weight and gestational age were 795 (705, 972) grams and 25 (25, 27) weeks. The duration of an intubation attempt was 35 (27, 46) seconds with number of attempts 2 (1, 2). There were 34 intubation attempts greater than 30 seconds (prolonged group) and 18 attempts less than or equal to 30 seconds (short group). Longer attempts did not affect intubation success (successful 34 [25,37] seconds vs. unsuccessful 41[29, 53] seconds; P=0.05). Infants in the prolonged group had a greater decrease in oxygen saturation percentage from baseline (5±8 percent, short intubation group and 13±27 prolonged intubation group; P=0.004). There was also a significant decrease in heart rate beats per minute between the two groups (6±9 in the short intubation group and 23±29

  5. Heart rate detection from an electronic weighing scale

    International Nuclear Information System (INIS)

    González-Landaeta, R; Casas, O; Pallàs-Areny, R

    2008-01-01

    We propose a novel technique for beat-to-beat heart rate detection based on the ballistocardiographic (BCG) force signal from a subject standing on a common electronic weighing scale. The detection relies on sensing force variations related to the blood acceleration in the aorta, works even if wearing footwear and does not require any sensors attached to the body because it uses the load cells in the scale. We have devised an approach to estimate the sensitivity and frequency response of three commercial weighing scales to assess their capability to detect the BCG force signal. Static sensitivities ranged from 490 nV V −1 N −1 to 1670 nV V −1 N −1 . The frequency response depended on the subject's mass but it was broad enough for heart rate estimation. We have designed an electronic pulse detection system based on off-the-shelf integrated circuits to sense heart-beat-related force variations of about 0.24 N. The signal-to-noise ratio of the main peaks of the force signal detected was higher than 30 dB. A Bland–Altman plot was used to compare the RR time intervals estimated from the ECG and BCG force signals for 17 volunteers. The error was ±21 ms, which makes the proposed technique suitable for short-term monitoring of the heart rate

  6. Guided imagery, anxiety, heart rate, and heart rate variability during centrifuge training.

    Science.gov (United States)

    Jing, Xiaolu; Wu, Ping; Liu, Fang; Wu, Bin; Miao, Danmin

    2011-02-01

    Centrifuge training is an important method of improving the hypergravity tolerance of pilots, cosmonauts, and Chinese astronauts. However, the concomitants of tension or anxiety often impede training. Guided imagery (GI), a mind-body relaxation technique, provides a behavioral and cognitive means whereby individuals are able to exert control over the focus of attention. This study aims to investigate the immediate effects of GI for reducing stress in centrifuge training. There were 12 healthy young men who were randomly assigned to a GI group or music group. We measured changes in heart rate during centrifuge training, in heart rate variability before and after centrifuge training, and also evaluated relaxation and anxiety in three phases: before intervention, after intervention, and following centrifuge training. The change in the pattern of anxiety was different in the two groups over the three phases. Anxiety (measured by State Anxiety Inventory) in the GI group changed from 31.7 +/- 5.9 to 26.8 +/- 2.6 and 27.8 +/- 4.1, whereas for the music group this changed from 32.2 +/- 7.6 to 31.2 +/- 8.3 and 26.8 +/- 6.8. During centrifuge training, the maximal HR for the GI group (101.2 +/- 8.8) was lower than that of the music group (123.0 +/- 19.1). In addition GI showed a decrease in low frequency (LF, 0.04-0.15 Hz) components and an increase in high frequency (HF, 0.15-0.4 Hz) components before and after centrifuge training. GI was capable of decreasing tension, anxiety, and sympathetic nervous system activity pre- or post-centrifugation.

  7. Resonance of about-weekly human heart rate rhythm with solar activity change.

    Science.gov (United States)

    Cornelissen, G; Halberg, F; Wendt, H W; Bingham, C; Sothern, R B; Haus, E; Kleitman, E; Kleitman, N; Revilla, M A; Revilla, M; Breus, T K; Pimenov, K; Grigoriev, A E; Mitish, M D; Yatsyk, G V; Syutkina, E V

    1996-12-01

    In several human adults, certain solar activity rhythms may influence an about 7-day rhythm in heart rate. When no about-weekly feature was found in the rate of change in sunspot area, a measure of solar activity, the double amplitude of a circadian heart rate rhythm, approximated by the fit of a 7-day cosine curve, was lower, as was heart rate corresponds to about-weekly features in solar activity and/or relates to a sunspot cycle.

  8. Separating the effect of respiration from the heart rate variability for cases of constant harmonic breathing

    Directory of Open Access Journals (Sweden)

    Kircher Michael

    2015-09-01

    Full Text Available Heart Rate Variability studies are a known measure for the autonomous control of the heart rate. In special situations, its interpretation can be ambiguous, since the respiration has a major influence on the heart rate variability. For this reason it has often been proposed to measure Heart Rate Variability, while the subjects are breathing at a constant respiration rate. That way the spectral influence of the respiration is known. In this work we propose to remove this constant respiratory influence from the heart rate and the Heart Rate Variability parameters to gain respiration free autonomous controlled heart rate signal. The spectral respiratory component in the heart rate signal is detected and characterized. Subsequently the respiratory effect on Heart Rate Variability is removed using spectral filtering approaches, such as the Notch filter or the Raised Cosine filter. As a result new decoupled Heart Variability parameters are gained, which could lead to new additional interpretations of the autonomous control of the heart rate.

  9. Functionality of the baroreceptor nerves in heart rate regulation

    DEFF Research Database (Denmark)

    Ottesen, Johnny T.; Olufsen, Mette

    2011-01-01

    are a consequence of the memory encapsulated by the models, and the nonlinearity gives rise to sigmoidal response curves. The nonlinear afferent baroreceptor models are coupled with an effector model, and the coupled model has been used to predict baroreceptor feedback regulation of heart rate during postural...... change from sitting to standing and during head-up tilt. The efferent model couples the afferent nerve paths to the sympathetic and parasympathetic outflow, and subsequently predicts the build up of an action potential at the sinus knot of the heart. In this paper, we analyze the nonlinear afferent model...... and show that the coupled model is able to predict heart rate regulation using blood pressure data as an input...

  10. Unconstrained monitoring of long-term heart and breath rates during sleep

    International Nuclear Information System (INIS)

    Chen, Wenxi; Zhu, Xin; Wei, Daming; Nemoto, Tetsu; Sugitani, Kayo; Kitamura, Kei-ichiro

    2008-01-01

    An unconstrained method for the long-term monitoring of heart and breath rates during sleep is proposed. The system includes a sensor unit and a web-based network module. The sensor unit is set beneath a pillow to pick up the pressure variations from the head induced by inhalation/exhalation movements and heart pulsation during sleep. The measured pressure signal was digitized and transferred to a remote database server via the network module. A wavelet-based algorithm was employed to detect the heart and breath rates, as well as body movement, during sleep. The overall system was utilized for a total six-month trial operation delivered to a female subject. The profiles of the heart and breath rates on a beat-by-beat and daily basis were obtained. Movements during sleep were also estimated. The results show that the daily average percentage of undetectable periods (UPs) during 881.6 sleep hours over a 180 day period was 17.2%. A total of 89.2% of sleep hours had a UP of not more than 25%. The profile of the heart rate revealed a periodic property that corresponded to the female monthly menstrual cycle. Our system shows promise as a long-term unconstrained monitor for heart and breath rates, and for other physiological parameters related to the quality of sleep and the regularity of the menstrual cycle. (note)

  11. Ambulatory ECG and analysis of heart rate variability in Parkinson's disease.

    Science.gov (United States)

    Haapaniemi, T H; Pursiainen, V; Korpelainen, J T; Huikuri, H V; Sotaniemi, K A; Myllylä, V V

    2001-03-01

    Cardiovascular reflex tests have shown both sympathetic and parasympathetic failure in Parkinson's disease. These tests, however, describe the autonomic responses during a restricted time period and have great individual variability, providing a limited view of the autonomic cardiac control mechanisms. Thus, they do not reflect tonic autonomic regulation. The aim was to examine tonic autonomic cardiovascular regulation in untreated patients with Parkinson's disease. 24 Hour ambulatory ECG was recorded in 54 untreated patients with Parkinson's disease and 47 age matched healthy subjects. In addition to the traditional spectral (very low frequency, VLF; low frequency, LF; high frequency, HF) and non-spectral components of heart rate variability, instantaneous beat to beat variability (SD1) and long term continuous variability (SD2) derived from Poincaré plots, and the slope of the power law relation were analysed. All spectral components (plaw relation (pParkinson's disease than in the control subjects. The Unified Parkinson's disease rating scale total and motor scores had a negative correlation with VLF and LF power spectrum values and the power law relation slopes. Patients with mild hypokinesia had higher HF values than patients with more severe hypokinesia. Tremor and rigidity were not associated with the HR variability parameters. Parkinson's disease causes dysfunction of the diurnal autonomic cardiovascular regulation as demonstrated by the spectral measures of heart rate variability and the slope of the power law relation. This dysfunction seems to be more profound in patients with more severe Parkinson's disease.

  12. Real-time heart rate measurement for multi-people using compressive tracking

    Science.gov (United States)

    Liu, Lingling; Zhao, Yuejin; Liu, Ming; Kong, Lingqin; Dong, Liquan; Ma, Feilong; Pang, Zongguang; Cai, Zhi; Zhang, Yachu; Hua, Peng; Yuan, Ruifeng

    2017-09-01

    The rise of aging population has created a demand for inexpensive, unobtrusive, automated health care solutions. Image PhotoPlethysmoGraphy(IPPG) aids in the development of these solutions by allowing for the extraction of physiological signals from video data. However, the main deficiencies of the recent IPPG methods are non-automated, non-real-time and susceptible to motion artifacts(MA). In this paper, a real-time heart rate(HR) detection method for multiple subjects simultaneously was proposed and realized using the open computer vision(openCV) library, which consists of getting multiple subjects' facial video automatically through a Webcam, detecting the region of interest (ROI) in the video, reducing the false detection rate by our improved Adaboost algorithm, reducing the MA by our improved compress tracking(CT) algorithm, wavelet noise-suppression algorithm for denoising and multi-threads for higher detection speed. For comparison, HR was measured simultaneously using a medical pulse oximetry device for every subject during all sessions. Experimental results on a data set of 30 subjects show that the max average absolute error of heart rate estimation is less than 8 beats per minute (BPM), and the processing speed of every frame has almost reached real-time: the experiments with video recordings of ten subjects under the condition of the pixel resolution of 600× 800 pixels show that the average HR detection time of 10 subjects was about 17 frames per second (fps).

  13. Aggressive behavior: an alternative model of resting heart rate and sensation seeking.

    Science.gov (United States)

    Wilson, Laura C; Scarpa, Angela

    2014-01-01

    Low resting heart rate is a well-replicated biological correlate of aggression, and sensation seeking is frequently cited as the underlying causal explanation. However, little empirical evidence supports this mediating relationship. Furthermore, the biosocial model of violence and social push theory suggest sensation seeking may moderate the relationship between heart rate and aggression. In a sample of 128 college students (82.0% White; 73.4% female), the current study tested a moderation model as an alternative relationship between resting heart rate and sensation seeking in regard to aggression. Overall, the findings partially supported an interaction effect, whereby the relationship between heart rate and aggression was moderated by sensation seeking. Specifically, the oft-noted relationship between low resting heart rate and increased aggression was found, but only for individuals with low levels of sensation seeking. If replication supports this finding, the results may better inform prevention and intervention work. © 2013 Wiley Periodicals, Inc.

  14. Non-linear indices of heart rate variability during endodontic treatment.

    Science.gov (United States)

    Santana, Milana Drumond Ramos; Pita Neto, Ivo Cavalcante; Martiniano, Eli Carlos; Monteiro, Larissa Raylane Lucas; Ramos, José Lucas Souza; Garner, David M; Valenti, Vitor Engácia; Abreu, Luiz Carlos de

    2016-01-01

    Dental treatment promotes psychosomatic change that can influence the procedure and compromise the general well-being of the patient. In this context, it highlights the importance of evaluating the function of the autonomic nervous system in individuals undergoing endodontic treatment. Thus, this manuscript aimed to analyse cardiac autonomic modulation, through non-linear indices of heart rate variability (HRV) during endodontic treatment. Analysis of 50 subjects of either sex aged between 18 and 40 years diagnosed with irreversible pulp necrosis of lower molars undergoing endodontic treatment was undertaken. We carried out fractal and symbolic analysis of HRV, which was recorded in the first session of the endodontic treatment at four intervals: T1: 0-10 min before the onset of the treatment session; T2: 0-10 min after the application of anaesthesia; T3: throughout the period of treatment; and T4: 0-30 min after the end of the treatment session. There was reduction of α1 in T2 compared to T1 and T4 (p endodontic treatment, and after applying local anaesthetic the parasympathetic component of HRV increases. These data indicate that endodontic treatment acutely overcharges the heart, supporting the stress involved in this situation.

  15. Assessment of baroreflex sensitivity from spontaneous oscillations of blood pressure and heart rate: proven clinical value?

    International Nuclear Information System (INIS)

    Pinna, Gian Domenico; Maestri, Roberto; La Rovere, Maria Teresa

    2015-01-01

    The baroreceptor-heart rate reflex (baroreflex sensitivity, BRS) is a key mechanism contributing to the neural regulation of the cardiovascular system. Several methods have been proposed so far to assess BRS by analyzing the spontaneous beat-to-beat fluctuations of arterial blood pressure and heart rate. These methods are inherently simple, non-invasive and low-cost. This study is an attempt to address the question of whether spontaneous baroreflex methods have proven to be of value in the clinical setting. In the first part of this article, we critically review most representative clinical studies using spontaneous BRS techniques either for risk stratification or treatment evaluation, these being major issues in the clinical management of the patients. In the second part, we address two important aspects of spontaneous BRS measurements: measurability and reliability. Estimation of BRS in the studies selected for the review was performed according to the sequence, transfer function, alpha-index and phase-rectified signal averaging method. Arterial blood pressure was recorded non-invasively during supine, short-term (<30 min) laboratory recordings. The conclusion from this review is that spontaneous BRS techniques have been shown to be of great value in clinical practice but further work is needed to confirm the validity of previous findings and to widen the field of clinical applications. Measurability and reliability can be a major issue in the measurement of spontaneous BRS, particularly in some patient populations like post-myocardial infarction and heart failure patents. Main causes of poor measurability are: non-sinus rhythm, a high rate of ectopic beats and the need for recorded time series of RR interval and arterial blood pressure to satisfy the constraints of the different BRS estimation algorithms. As for reliability, within-subject variability is rather high in the measurements of spontaneous BRS and, therefore, should be carefully taken into account

  16. Heart Rate and Increased Intravascular Volume

    Czech Academy of Sciences Publication Activity Database

    Souček, M.; Kára, T.; Jurák, Pavel; Halámek, Josef; Špinarová, L.; Meluzín, J.; Toman, J.; Řiháček, I.; Šumbera, J.; Fráňa, P.

    2003-01-01

    Roč. 52, - (2003), s. 137 - 140 ISSN 0862-8408 R&D Projects: GA ČR GA102/02/1339 Institutional research plan: CEZ:AV0Z2065902 Keywords : kidneys * heart rate * atrial mechanisms Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 0.939, year: 2003

  17. Field Measurements Indicate Unexpected, Serious Underestimation of Mussel Heart Rates and Thermal Tolerance by Laboratory Studies.

    Directory of Open Access Journals (Sweden)

    Morgana Tagliarolo

    Full Text Available Attempts to predict the response of species to long-term environmental change are generally based on extrapolations from laboratory experiments that inevitably simplify the complex interacting effects that occur in the field. We recorded heart rates of two genetic lineages of the brown mussel Perna perna over a full tidal cycle in-situ at two different sites in order to evaluate the cardiac responses of the two genetic lineages present on the South African coast to temperature and the immersion/emersion cycle. "Robomussel" temperature loggers were used to monitor thermal conditions at the two sites over one year. Comparison with live animals showed that robomussels provided a good estimate of mussel body temperatures. A significant difference in estimated body temperatures was observed between the sites and the results showed that, under natural conditions, temperatures regularly approach or exceed the thermal limits of P. perna identified in the laboratory. The two P. perna lineages showed similar tidal and diel patterns of heart rate, with higher cardiac activity during daytime immersion and minimal values during daytime emersion. Comparison of the heart rates measured in the field with data previously measured in the laboratory indicates that laboratory results seriously underestimate heart rate activity, by as much as 75%, especially during immersion. Unexpectedly, field estimates of body temperatures indicated an ability to tolerate temperatures considered lethal on the basis of laboratory measurements. This suggests that the interaction of abiotic conditions in the field does not necessarily raise vulnerability to high temperatures.

  18. Association Between Baseline Blood Pressures, Heart Rates, and Vasovagal Syncope in Children and Adolescents.

    Science.gov (United States)

    Adlakha, Himanshu; Gupta, Ruchi; Hassan, Romana; Kern, Jeffrey H

    2018-01-28

    Vasovagal syncope is the most common cause of syncope in children and adults, accounting for 50-66% of unexplained syncope. There are no studies establishing the relationship between syncope, baseline heart rate, and blood pressure. To identify a possible association between baseline blood pressure and heart rate with syncope. We conducted a questionnaire-based chart review study. A questionnaire was distributed to the guardian of children between eight and 18 years of age who attended the Pediatric Ambulatory Care Clinic at Flushing Hospital Medical Center. Based on the responses in the questionnaire, subjects were classified either as cases (positive for syncope) or controls (negative for syncope). Children and adolescents with neurological, cardiac, or any medical condition that can cause syncopal episodes were excluded from the study. Data collected from the questionnaire included age, gender, ethnicity, medical history, family history of syncope, and the amount of salt used in food. Anthropometric and vital signs for the current visit (height, weight, BMI, blood pressure, and heart rate) and vital signs from two previous visits were collected from electronic medical records. The data was analyzed using t-test and chi-square test with Microsoft Excel software (Microsoft Office Standard, v. 14, Microsoft; 2010); p<0.05 was considered significant. A total of 197 subjects were included in this study. There were 18 cases and 179 controls. Of the cases, (4/18) 22.2% were more likely to have a systolic blood pressure lower than the 10th percentile for their gender, age, and height as compared with controls (7/179) 3.9%, p = 0.003. The subjects with a history of syncope were more likely to add salt to their food (p = 0.004). There were no significant differences between cases and controls for age, gender, ethnicity between cases and controls for systolic blood pressure. No significant difference was observed between the heart rates of cases and controls. Children

  19. Assessing positive emotional states in dogs using heart rate and heart rate variability.

    Science.gov (United States)

    Zupan, Manja; Buskas, Julia; Altimiras, Jordi; Keeling, Linda J

    2016-03-01

    Since most animal species have been recognized as sentient beings, emotional state may be a good indicator of welfare in animals. The goal of this study was to manipulate the environment of nine beagle research dogs to highlight physiological responses indicative of different emotional experiences. Stimuli were selected to be a more or a less positive food (meatball or food pellet) or social reward (familiar person or less familiar person). That all the stimuli were positive and of different reward value was confirmed in a runway motivation test. Dogs were tested individually while standing facing a display theatre where the different stimuli could be shown by lifting a shutter. The dogs approached and remained voluntarily in the test system. They were tested in four sessions (of 20s each) for each of the four stimuli. A test session consisted of four presentation phases (1st exposure to stimulus, post exposure, 2nd exposure, and access to reward). Heart rate (HR) and heart rate variability (HRV) responses were recorded during testing in the experimental room and also when lying resting in a quiet familiar room. A new method of 'stitching' short periods of HRV data together was used in the analysis. When testing different stimuli, no significant differences were observed in HR and LF:HF ratio (relative power in low frequency (LF) and the high-frequency (HF) range), implying that the sympathetic tone was activated similarly for all the stimuli and may suggest that dogs were in a state of positive arousal. A decrease of HF was associated with the meatball stimulus compared to the food pellet and the reward phase (interacting with the person or eating the food) was associated with a decrease in HF and RMSSD (root mean square of successive differences of inter-beat intervals) compared to the preceding phase (looking at the person or food). This suggests that parasympathetic deactivation is associated with a more positive emotional state in the dog. A similar reduction

  20. Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring.

    Science.gov (United States)

    Lin, Zhiming; Chen, Jun; Li, Xiaoshi; Zhou, Zhihao; Meng, Keyu; Wei, Wei; Yang, Jin; Wang, Zhong Lin

    2017-09-26

    Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, noninvasive, and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure-based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit, and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to an external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG-based generator and a TENG-based sensor, an all-TENG-based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, noninvasive, and user-friendly.

  1. ISOMETRIC EXERCISE AND ITS EFFECT ON BLOOD PRESSURE AND HEART RATE, BEFORE AND AFTER TRAINING IN YOUNG HEALTHY MALES

    Directory of Open Access Journals (Sweden)

    Mohammed

    2015-05-01

    Full Text Available INTRODUCTION: Isometric exercise is a normal part of everyday activities and many occupational tasks. Preventive services are important as they give physicians an opportunity and responsibility to promote regular physical activity, reduc e high blood pressure, and help in weight control. Physical inactivity is recognized as a risk factor for coronary artery disease. Regular aerobic physical activity increases exercise capacity and plays a role in both primary and secondary prevention of ca rdiovascular disease. OBJECTIVE: To assess the effects of isometric handgrip training on Blood pressure and Heart rate in healthy young males in the age group of 18 - 22 years. MATERIALS AND METHOD : Study subjects consisted of 30 healthy adult males in the age group of 18 - 22 yrs. Age and sex matched adults who were not active in sports or in physical activities constituted the control group (n=30. Blood pressure and heart rate were recorded and eval uated after a defined protocol of handgrip sustained static (isometric contractions performed with the handgrip dynamometer at Rest and Post Exercise. BP and HR were recorded with the help of automated blood pressure monitor and power lab 8/30 series inst rument available in the Department of Physiology , Navodaya Medical college, Raichur. RESULTS: There was no change in Resting Blood pressure and Heart rate between the subject and control group before the training sessions. There was significant decrease in resting Blood pressure and Heart rate in trained subject group when compared to untrained control group after 5 weeks of training sessions. CONCLUSION : Isometric hand grip training is effective in lowering arterial pressure in normotensive subjects. Isome tric training may be an effective intervention in the prevention and treatment of hypertension

  2. Heart rate effects of intraosseous injections using slow and fast rates of anesthetic solution deposition.

    Science.gov (United States)

    Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa

    2008-01-01

    The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe.

  3. Resting heart rate in infants and toddlers: variations associated with early infant diet and the omega 3 fatty acid DHA

    Science.gov (United States)

    Although early postnatal nutrition can have long-term effects on developmental processes, the influence of infant diet on the maturation of cardiac development has not been documented. To study this relationship we recorded resting heart-rate (HR) in awake, healthy infants and toddlers exclusively b...

  4. Value of Serial Heart Rate Variability Measurement for Prediction of Appropriate ICD Discharge in Patients with Heart Failure

    NARCIS (Netherlands)

    ten Sande, Judith N.; Damman, Peter; Tijssen, Jan G. P.; de Groot, Joris R.; Knops, Reinoud E.; Wilde, Arthur A. M.; van Dessel, Pascal F. H. M.

    2014-01-01

    HRV and Appropriate ICD Shock in Heart Failure Introduction Decreased heart rate variability (HRV) is associated with adverse outcomes in patients with heart failure. Our objective was to examine whether decreased HRV predicts appropriate implantable cardioverter defibrillator (ICD) shocks. Methods

  5. Long-Term Persistency of Abnormal Heart Rate Variability following Long NICU Stay and Surgery at Birth

    Directory of Open Access Journals (Sweden)

    Mélanie Morin

    2014-01-01

    Full Text Available Preterm birth is associated with painful procedures during the neonatal intensive care unit (NICU stay. Full-term newborns can also experience pain, following surgery. These procedures can have long-lasting consequences. It has been shown that children born preterm show pain responses and cardiac alterations. This study aimed to explore the heart rate reactivity to pain in 107 subjects born either preterm or full-term who were between 7 and 25 years old at testing. We also evaluated the effect of pain experienced at birth, as represented by a longer NICU stay, time under ventilation, and surgery at birth. Participants were asked to immerse their right forearm in 10°C water for 2 minutes. Electrocardiograms were recorded at baseline and during the immersion procedure. Full-term subjects showed a stable increase in heart rate throughout the procedure, whereas preterm ones showed a strong increase at the beginning, which decreased over time. Also, preterm and full-term subjects who experienced pain at birth showed higher resting heart rate, stronger sympathetic activity, and lower cardiac vagal activity. Our study demonstrated a long-term impact of a long NICU stay and surgery at birth on cardiac autonomic activity. This could lead to impaired reactions to pain or stress in later life.

  6. Smart pillow for heart-rate monitoring using a fiber optic sensor

    Science.gov (United States)

    Chen, Zhihao; Teo, Ju Teng; Ng, Soon Huat; Yim, Huiqing

    2011-03-01

    In this paper, we propose and demonstrate a new method to monitor heart rate using fiber optic microbending based sensor for in-bed non-intrusive monitoring. The sensing system consists of transmitter, receiver, sensor mat, National Instrument (NI) data acquisition (DAQ) card and a computer for signal processing. The sensor mat is embedded inside a commercial pillow. The heart rate measurement system shows an accuracy of +/-2 beats, which has been successfully demonstrated in a field trial. The key technological advantage of our system is its ability to measure heart rate with no preparation and minimal compliance by the patient.

  7. QT measurement and heart rate correction during hypoglycemia

    DEFF Research Database (Denmark)

    Christensen, Toke Folke; Randløv, Jette; Christensen, Leif Engmann

    2010-01-01

    induced by intravenous injection of two insulin types in a cross-over design. QT measurements were done using the slope-intersect (SI) and manual annotation (MA) methods. Heart rate correction was done using Bazett's (QTcB) and Fridericia's (QTcF) formulas. Results. The SI method showed significant......Introduction. Several studies show that hypoglycemia causes QT interval prolongation. The aim of this study was to investigate the effect of QT measurement methodology, heart rate correction, and insulin types during hypoglycemia. Methods. Ten adult subjects with type 1 diabetes had hypoglycemia...... prolongation at hypoglycemia for QTcB (42(6) ms; P measuring the QT interval has...

  8. Estimating energy expenditure from heart rate in older adults: a case for calibration.

    Science.gov (United States)

    Schrack, Jennifer A; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M; Ferrucci, Luigi

    2014-01-01

    Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using different levels of calibration. Heart rate and energy expenditure were assessed across five levels of exertion in 290 adults participating in the Baltimore Longitudinal Study of Aging. Correlation and random effects regression analyses assessed the linearity of the relationship between heart rate and energy expenditure and cross-validation models assessed predictive performance. Heart rate and energy expenditure were highly correlated (r=0.98) and linear regardless of age or sex. Intra-person variability was low but inter-person variability was high, with substantial heterogeneity of the random intercept (s.d. =0.372) despite similar slopes. Cross-validation models indicated individual calibration data substantially improves accuracy predictions of energy expenditure from heart rate, reducing the potential for considerable measurement bias. Although using five calibration measures provided the greatest reduction in the standard deviation of prediction errors (1.08 kcals/min), substantial improvement was also noted with two (0.75 kcals/min). These findings indicate standard regression equations may be used to make population-level inferences when estimating energy expenditure from heart rate in older adults but caution should be exercised when making inferences at the individual level without proper calibration.

  9. Resemblances of Parents and Twins in Sport Participation and Heart Rate

    NARCIS (Netherlands)

    Boomsma, D.I.; van den Bree, M.B.; Orlebeke, J.F.; Molenaar, P.C.M.

    1989-01-01

    A model to analyze resemblances of twins and parents using LISREL is outlined and applied to sports participation and heart-rate data. Sports participation and heart rate were measured in 44 monozygotic and 46 dizygotic adolescent twin pairs and in their parents. Genetic factors influence variation

  10. Gaussian Mixture Model of Heart Rate Variability

    Science.gov (United States)

    Costa, Tommaso; Boccignone, Giuseppe; Ferraro, Mario

    2012-01-01

    Heart rate variability (HRV) is an important measure of sympathetic and parasympathetic functions of the autonomic nervous system and a key indicator of cardiovascular condition. This paper proposes a novel method to investigate HRV, namely by modelling it as a linear combination of Gaussians. Results show that three Gaussians are enough to describe the stationary statistics of heart variability and to provide a straightforward interpretation of the HRV power spectrum. Comparisons have been made also with synthetic data generated from different physiologically based models showing the plausibility of the Gaussian mixture parameters. PMID:22666386

  11. Adaptive Mean and Trend Removal of Heart Rate Variability Using Kalman Filtering

    National Research Council Canada - National Science Library

    Schloegl, A

    2001-01-01

    Analysis of heart rate van ability requires the calculation of the mean heart rate, Adaptive methods are important for online and real-time parameter estimation, In this paper we demonstrate the use...

  12. Sleep Quality Estimation based on Chaos Analysis for Heart Rate Variability

    Science.gov (United States)

    Fukuda, Toshio; Wakuda, Yuki; Hasegawa, Yasuhisa; Arai, Fumihito; Kawaguchi, Mitsuo; Noda, Akiko

    In this paper, we propose an algorithm to estimate sleep quality based on a heart rate variability using chaos analysis. Polysomnography(PSG) is a conventional and reliable system to diagnose sleep disorder and to evaluate its severity and therapeatic effect, by estimating sleep quality based on multiple channels. However, a recording process requires a lot of time and a controlled environment for measurement and then an analyzing process of PSG data is hard work because the huge sensed data should be manually evaluated. On the other hand, it is focused that some people make a mistake or cause an accident due to lost of regular sleep and of homeostasis these days. Therefore a simple home system for checking own sleep is required and then the estimation algorithm for the system should be developed. Therefore we propose an algorithm to estimate sleep quality based only on a heart rate variability which can be measured by a simple sensor such as a pressure sensor and an infrared sensor in an uncontrolled environment, by experimentally finding the relationship between chaos indices and sleep quality. The system including the estimation algorithm can inform patterns and quality of own daily sleep to a user, and then the user can previously arranges his life schedule, pays more attention based on sleep results and consult with a doctor.

  13. Heart rate variability in patients with systemic lupus erythematosus: a systematic review and methodological considerations.

    Science.gov (United States)

    Matusik, P S; Matusik, P T; Stein, P K

    2018-07-01

    Aim The aim of this review was to summarize current knowledge about the scientific findings and potential clinical utility of heart rate variability measures in patients with systemic lupus erythematosus. Methods PubMed, Embase and Scopus databases were searched for the terms associated with systemic lupus erythematosus and heart rate variability, including controlled vocabulary, when appropriate. Articles published in English and available in full text were considered. Finally, 11 publications were selected, according to the systematic review protocol and were analyzed. Results In general, heart rate variability, measured in the time and frequency domains, was reported to be decreased in patients with systemic lupus erythematosus compared with controls. In some systemic lupus erythematosus studies, heart rate variability was found to correlate with inflammatory markers and albumin levels. A novel heart rate variability measure, heart rate turbulence onset, was shown to be increased, while heart rate turbulence slope was decreased in systemic lupus erythematosus patients. Reports of associations of changes in heart rate variability parameters with increasing systemic lupus erythematosus activity were inconsistent, showing decreasing heart rate variability or no relationship. However, the low/high frequency ratio was, in some studies, reported to increase with increasing disease activity or to be inversely correlated with albumin levels. Conclusions Patients with systemic lupus erythematosus have abnormal heart rate variability, which reflects cardiac autonomic dysfunction and may be related to inflammatory cytokines but not necessarily to disease activity. Thus measurement of heart rate variability could be a useful clinical tool for monitoring autonomic dysfunction in systemic lupus erythematosus, and may potentially provide prognostic information.

  14. iHeartrate: a heart rate controlled in-flight music recommendation system

    NARCIS (Netherlands)

    Liu, H.; Hu, J.; Rauterberg, G.W.M.; Spink, A.J.; Grieco, O.E.; Krips, L.W.S.; Loijens, L.P.J.J.; Noldus, xx; Zimmerman, P.H.

    2010-01-01

    Travel by air, especially long distance, the enclosed environment of the aircraft cabin causes discomfort and even stress to flight passengers. In this paper, we present a new heart rate controlled music recommendation system. Heart rate is used as a stress indicator. If the user is stressed and

  15. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders

    DEFF Research Database (Denmark)

    den Hoed, Marcel; Eijgelsheim, Mark; Esko, Tõnu

    2013-01-01

    of dilated cardiomyopathy, congenital heart failure and/or sudden cardiac death. In addition, genetic susceptibility to increased heart rate is associated with altered cardiac conduction and reduced risk of sick sinus syndrome, and both heart rate-increasing and heart rate-decreasing variants associate...

  16. Multi-Functional Sensor System for Heart Rate, Body Position and Movement Intensity Analysis

    Directory of Open Access Journals (Sweden)

    Michael MAO

    2008-12-01

    Full Text Available A novel multi-functional wearable sensor has been developed with multi-axis accelerometer, disposable hydro-gel electrodes, and analog filtering components. This novel sensor implementation can be used for detecting common body positions, movement intensity, and measures bio-potential signals for ECG and heart rate analysis. Based on the novel sensor principle, a prototype combines position detection, heart rate detection, and motion intensity level detection together in a handheld device that records the physiological information and wirelessly transmits the signals through Bluetooth to a mobile phone. Static body positions such as standing/sitting, lying supine, prone, and on the sides have been detected with high accuracy (97.7 % during the subject tests. Further, an algorithm that detects body movement intensity that can potentially be applied in real-time monitoring physical activity level is proposed based on average variance values. Motion intensity results show variance values increase and exercise intensity increases for almost all of the cases. A clear relation between movement intensity level shown by an increase in frequency and/or speed of exercise increases the variance values detected in all three spatial axes.

  17. Nonlinear Heart Rate Variability features for real-life stress detection. Case study: students under stress due to university examination.

    Science.gov (United States)

    Melillo, Paolo; Bracale, Marcello; Pecchia, Leandro

    2011-11-07

    This study investigates the variations of Heart Rate Variability (HRV) due to a real-life stressor and proposes a classifier based on nonlinear features of HRV for automatic stress detection. 42 students volunteered to participate to the study about HRV and stress. For each student, two recordings were performed: one during an on-going university examination, assumed as a real-life stressor, and one after holidays. Nonlinear analysis of HRV was performed by using Poincaré Plot, Approximate Entropy, Correlation dimension, Detrended Fluctuation Analysis, Recurrence Plot. For statistical comparison, we adopted the Wilcoxon Signed Rank test and for development of a classifier we adopted the Linear Discriminant Analysis (LDA). Almost all HRV features measuring heart rate complexity were significantly decreased in the stress session. LDA generated a simple classifier based on the two Poincaré Plot parameters and Approximate Entropy, which enables stress detection with a total classification accuracy, a sensitivity and a specificity rate of 90%, 86%, and 95% respectively. The results of the current study suggest that nonlinear HRV analysis using short term ECG recording could be effective in automatically detecting real-life stress condition, such as a university examination.

  18. Six Years in the Life of a Mother Bear - The Longest Continuous Heart Rate Recordings from a Free-Ranging Mammal

    Science.gov (United States)

    Laske, Timothy G.; Iaizzo, Paul A.; Garshelis, David L.

    2017-01-01

    Physiological monitoring of free-ranging wild animals is providing new insights into their adaptations to a changing environment. American black bears (Ursus americanus) are highly adaptable mammals, spending up to half the year hibernating, and the remainder of the year attempting to gain weight on a landscape with foods that vary seasonally and year to year. We recorded heart rate (HR) and corresponding activity of an adult female black bear over the course of six years, using an implanted monitor. Despite yearly differences in food, and an every-other year reproductive cycle, this bear exhibited remarkable consistency in HR and activity. HR increased for 12 weeks in spring, from minimal hibernation levels (mean 20-25 beats/minute [bpm]; min 10 bpm) to summer active levels (July daytime: mean 95 bpm). Timing was delayed following one cold winter. In August the bear switched from primarily diurnal to nocturnal, coincident with the availability of baits set by legal hunters. Activity in autumn was higher when the bear was with cubs. Birthing of cubs in January was identified by a transient increase in HR and activity. Long-term physiological and behavioral monitoring is valuable for understanding adaptations of free-ranging animals to climate change, food availability, and human-related stressors.

  19. Heart rate monitoring in soccer: interest and limits during competitive match play and training, practical application.

    Science.gov (United States)

    Alexandre, Dellal; da Silva, Cristiano Diniz; Hill-Haas, Stephen; Wong, Del P; Natali, Antonio J; De Lima, Jorge R P; Bara Filho, Mauricio G B; Marins, Joao J C B; Garcia, Emerson Silami; Karim, Chamari

    2012-10-01

    The identification of physiological loads imposed by soccer training or match play reveals essential information, which may help improve training and recovery strategies. Until today, the use of heart rate (HR) monitoring is not standardized in soccer. Thus, the aim of this review was to analyze, determine and compare the exercise intensity (EI) monitored by HR in professional, youth, and recreational soccer players during matches and training sessions using a meta-analysis. Heart rate is one of the most common physiological variables used to determine exercise internal training load. The mean EI recorded during competitive matches was described as 70-80% of VO2max or 80-90% of maximal heart rate (HRmax), independent of the playing level. With respect to HR training zones, approximately 65% of the total match duration is spent at intensity of 70-90% HRmax and rarely below 65% HRmax. However, although HRmax is mostly employed in the literature, monitoring EI should be expressed in relation to reserve heart rate, as it was described as a more reliable indicator of HR, allowing interindividual comparisons. The HR response according to the playing position indicates that midfielders are characterized by the highest EI, followed by forwards and fullbacks. Moreover, in the second half of the match, the EI is lower than that observed during the first half; this reduction could be correlated with the level of the player's physical conditioning. Consequently, coaches may favor the use of interval training or small-sided training games because these are shown to improve both aerobic capacity and the ability to repeat high-intensity actions. Small-sided games allow reaching similar HR responses to those found during interval training and match play but with greater heterogeneity values. Future investigations should include a larger sample of players with special reference to playing position and the expression of EI in percentage of the reserve heart rate, analyzing the

  20. Heart rhythm analysis using ECG recorded with a novel sternum based patch technology

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Fauerskov, Inge; Osmanagic, Armin

    2013-01-01

    , reliable long-term ECG recordings. The device is designed for high compliance and low patient burden. This novel patch technology is CE approved for ambulatory ECG recording of two ECG channels on the sternum. This paper describes a clinical pilot study regarding the usefulness of these ECG signals...... for heart rhythm analysis. A clinical technician with experience in ECG interpretation selected 200 noise-free 7 seconds ECG segments from 25 different patients. These 200 ECG segments were evaluated by two medical doctors according to their usefulness for heart rhythm analysis. The first doctor considered...... 98.5% of the segments useful for rhythm analysis, whereas the second doctor considered 99.5% of the segments useful for rhythm analysis. The conclusion of this pilot study indicates that two channel ECG recorded on the sternum is useful for rhythm analysis and could be used as input to diagnosis...

  1. Heart rate variability to monitor performance in elite athletes: Criticalities and avoidable pitfalls.

    Science.gov (United States)

    Lucini, Daniela; Marchetti, Ilaria; Spataro, Antonio; Malacarne, Mara; Benzi, Manuela; Tamorri, Stefano; Sala, Roberto; Pagani, Massimo

    2017-08-01

    Spectral analysis of Heart Rate Variability (HRV) is a simple, non-invasive technique that is widely used in sport to assess sympatho-vagal regulation of the heart. Its employment is increasing partly due to the rising usage of wearable devices. However data acquisition using these devices may be suboptimal because they cannot discriminate between sinus and non-sinus beats and do not record any data regarding respiratory frequency. This information is mandatory for a correct clinical interpretation. This study involved 974 elite athletes, all of them underwent a complete autonomic assessment, by way of Autoregressive HRV analysis. In 91 subjects (9% of the total population) we observed criticalities of either cardiac rhythm or respiration. Through perusal of one-lead ECG analysis we observed that 77 subjects had atrial or ventricular ectopy, i.e. conditions which impair stationarity and sinus rhythm. Running anyway autonomic nervous system analysis in this population, we observed that RR variance and raw values of LF and HF regions are significantly higher in arrhythmic subjects. In addition 14 subjects had slow (about 6 breath/min, 0.1Hz) respiration. This condition clouds the separation between LF from HF spectral regions of RR interval variability, respectively markers of the prevalent sympathetic and vagal modulation of SA node and of their synergistic interaction. Caution must be payed when assessing HRV with non-ECG wearable devices. Recording ECG signal and ensuring that respiratory rate is higher than 10 breath/min are both prerequisites for a more reliable analysis of HRV particularly in athletes. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Heart rate variability as determinism with jump stochastic parameters.

    Science.gov (United States)

    Zheng, Jiongxuan; Skufca, Joseph D; Bollt, Erik M

    2013-08-01

    We use measured heart rate information (RR intervals) to develop a one-dimensional nonlinear map that describes short term deterministic behavior in the data. Our study suggests that there is a stochastic parameter with persistence which causes the heart rate and rhythm system to wander about a bifurcation point. We propose a modified circle map with a jump process noise term as a model which can qualitatively capture such this behavior of low dimensional transient determinism with occasional (stochastically defined) jumps from one deterministic system to another within a one parameter family of deterministic systems.

  3. Behaviour, heart rate, and heart rate variability in pigs exposed to novelty

    Directory of Open Access Journals (Sweden)

    Manja Zupan

    2016-03-01

    Full Text Available ABSTRACT In the present study, we investigated behavioural responses and determined parameters of heart rate variability (HRV to elucidate a relative activation of autonomic nervous system (ANS during baseline (10 min and in response to potentially stressful situations (10 min in two pig breeds and sexes. Gilts (n = 21 and barrows (n = 9 of the Landrace × Yorkshire (LY; n = 15 and Landrace/Yorkshire × Landrace/Duroc (LYLD; n = 15 breeds were subjected to a novel object test (NOT and a novel arena test (NAT. Basal ANS state differed in pigs across breeds but not sexes. Landrace × Yorkshire pigs had a significantly lower basal heart rate (HR and low-frequency band (LF with a higher root mean square of successive interbeat intervals (RMSSD and high-frequency band (HF than LYLD pigs. In the NOT, despite having similar cardiac responses, gilts had a longer duration of contact with a novel object, higher lying and standing duration, and a lower duration of walking compared with barrows. In the NAT, we found similar behaviour across sexes but a different degree of ANS state, with barrows having a significantly higher increase in LF/HF (power of the low frequency component divided by the power of the high-frequency band compared with gilts. Landrace/Yorkshire × Landrace/Duroc pigs showed longer duration of contact with a novel object in the NOT accompanied by less lying and standing than LY pigs in both tests. No difference in ANS activation between breeds was found in the NOT. In the NAT, HR increased more from baseline to testing in LY pigs than in LYLD pigs. There is a complex and often contradictory nature of relationships between behaviour and cardiac responses to novelty in pigs of different breeds and sexes.

  4. Effects of metronome breathing on the assessment of autonomic control using heart rate variability

    NARCIS (Netherlands)

    Haaksma, J; Brouwer, J; vandenBerg, MP; Dijk, WA; Dassen, WRM; Crijns, HJGM; Mulder, Lambertus; Mulder, Gysbertus

    1996-01-01

    Analysis of Heart Rate Variability is a non-invasive quantitative tool to study the influence of the autonomic nervous system on the heart. Rapid variations in heart rate, related to breathing are primarily mediated by the vagal limb of the autonomic nervous system. The resulting variations in heart

  5. Detection of heart rate and rhythm with a smartphone-based electrocardiograph versus a reference standard electrocardiograph in dogs and cats.

    Science.gov (United States)

    Kraus, Marc S; Gelzer, Anna R; Rishniw, Mark

    2016-07-15

    OBJECTIVE To evaluate the diagnostic utility of ECGs acquired with a smartphone-based device, compared with reference 6-lead ECGs, for identification of heart rate and rhythm in dogs and cats. DESIGN Prospective study. ANIMALS 51 client-owned dogs and 27 client-owned cats. PROCEDURES Patients examined by a small animal referral cardiology service between April 2012 and January 2013 were enrolled consecutively. In each patient, a 30-second ECG was simultaneously acquired with a smartphone-based device (a bipolar, single-lead recorder coupled to a smartphone with an ECG application) and a standard 6-lead ECG machine. Recordings were evaluated by 3 board-certified cardiologists, and intra- and interobserver agreement were evaluated for both rhythm diagnosis and QRS polarity identification. RESULTS Values for instantaneous and mean heart rates for the smartphone-acquired and reference ECGs were within 1 beat of each other when mean heart rates were calculated. Intraobserver agreement for rhythm assessment was very high, with maximum disagreement for any observer for only 2 of 51 dogs and only 4 of 27 cats. There was minimal disagreement in the polarity of depolarization between the smartphone-acquired and reference ECGs in dogs but frequent disagreement in cats. Interobserver agreement for smartphone-acquired ECGs was similar to that for reference ECGs. with all 3 observers agreeing on the rhythm analysis and minimal disagreement on polarity. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that ECGs acquired with the smartphone-based device accurately identified heart rate and rhythm in dogs and cats. Thus, the device may allow veterinarians to evaluate and manage cardiac arrhythmias relatively inexpensively at the cage side and could also allow clinicians to rapidly share information via email for further consultation, potentially enhancing patient care.

  6. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Wei [Texas Children' s Hospital, E. B. Singleton Department of Pediatric Radiology, Houston, TX (United States); Bogale, Saivivek [Baylor University Medical Center, Department of Radiology, Dallas, TX (United States); Golriz, Farahnaz [Baylor College of Medicine, Department of Radiology, Houston, TX (United States); Krishnamurthy, Rajesh [Nationwide Children' s Hospital, Department of Diagnostic Radiology, Columbus, OH (United States)

    2017-11-15

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole. (orig.)

  7. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    Science.gov (United States)

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  8. Heart Rate and Energy Expenditure in Division I Field Hockey Players During Competitive Play.

    Science.gov (United States)

    Sell, Katie M; Ledesma, Allison B

    2016-08-01

    Sell, KM and Ledesma, AB. Heart rate and energy expenditure in Division I field hockey players during competitive play. J Strength Cond Res 30(8): 2122-2128, 2016-The purpose of this study was to quantify energy expenditure and heart rate data for Division I female field hockey players during competitive play. Ten female Division I collegiate field hockey athletes (19.8 ± 1.6 years; 166.4 ± 6.1 cm; 58.2 ± 5.3 kg) completed the Yo-Yo intermittent endurance test to determine maximal heart rate. One week later, all subjects wore a heart rate monitor during a series of 3 matches in an off-season competition. Average heart rate (AvHR), average percentage of maximal heart rate (AvHR%), peak exercise heart rate (PExHR), and percentage of maximal heart rate (PExHR%), time spent in each of the predetermined heart rate zones, and caloric expenditure per minute of exercise (kcalM) were determined for all players. Differences between positions (backs, midfielders, and forwards) were assessed. No significant differences in AvHR, AvHR%, PExHR, PExHR%, and %TM were observed between playing positions. The AvHR% and PExHR% for each position fell into zones 4 (77-93% HRmax) and 5 (>93% HRmax), respectively, and significantly more time was spent in zone 4 compared with zones 1, 2, 3, and 5 across all players (p ≤ 0.05). The kcalM reflected very heavy intensity exercise. The results of this study will contribute toward understanding the sport-specific physiological demands of women's field hockey and has specific implications for the duration and schedule of training regimens.

  9. Bluetooth(Registered Trademark) Heart Rate Monitors for Spaceflight

    Science.gov (United States)

    Buxton, Roxanne E.; West, Michael R.; Kalogera, Kent L.; Hanson, Andrea M.

    2016-01-01

    Heart rate monitoring is required during exercise for crewmembers aboard the International Space Station (ISS) and will be for future exploration missions. The cardiovascular system must be sufficiently stressed throughout a mission to maintain the ability to perform nominal and contingency/emergency tasks. High quality heart rate data is required to accurately determine the intensity of exercise performed by the crewmembers and show maintenance of VO2max. The quality of the data collected on ISS is subject to multiple limitations and is insufficient to meet current requirements. PURPOSE: To evaluate the performance of commercially available Bluetooth® heart rate monitors (BT_HRM) and their ability to provide high quality heart rate data to monitor crew health on board ISS and during future exploration missions. METHODS: Nineteen subjects completed 30 data collection sessions of various intensities on the treadmill and/or cycle. Subjects wore several BT_HRM technologies for each testing session. One electrode-based chest strap (CS) was worn, while one or more optical sensors (OS) was worn. Subjects were instrumented with a 12-lead ECG to compare the heart rate data from the Bluetooth sensors. Each BT_RHM data set was time matched to the ECG data and a +/-5bpm threshold was applied to the difference between the two data sets. Percent error was calculated based on the number of data points outside the threshold and the total number of data points. REULTS: The electrode-based chest straps performed better than the optical sensors. The best performing CS was CS1 (1.6%error), followed by CS4 (3.3%error), CS3 (6.4%error), and CS2 (9.2%error). The OS resulted in 10.4% error for OS1 and 14.9% error for OS2. CONCLUSIONS: The highest quality data came from CS1, unfortunately it has been discontinued by the manufacturer. The optical sensors have not been ruled out for use, but more investigation is needed to determine how to get the best quality data. CS2 will be used in an

  10. Paradoxical response to an emotional task: Trait characteristics and heart-rate dynamics

    NARCIS (Netherlands)

    Balocchia, R.; Varanini, M.; Paoletti, G.; Mecacci, G.; Santarcangelo, E.L.

    2015-01-01

    The present study evaluated the heart-rate dynamics of subjects reporting decreased (responders) or paradoxically increased relaxation (nonresponders) at the end of a threatening movie. Heart-rate dynamics were characterized by indices extracted through recurrence quantification analysis (RQA) and

  11. Application of Overall Dynamic Body Acceleration as a Proxy for Estimating the Energy Expenditure of Grazing Farm Animals: Relationship with Heart Rate

    Science.gov (United States)

    Miwa, Masafumi; Oishi, Kazato; Nakagawa, Yasuhiro; Maeno, Hiromichi; Anzai, Hiroki; Kumagai, Hajime; Okano, Kanji; Tobioka, Hisaya; Hirooka, Hiroyuki

    2015-01-01

    Estimating the energy expenditure of farm animals at pasture is important for efficient animal management. In recent years, an alternative technique for estimating energy expenditure by measuring body acceleration has been widely performed in wildlife and human studies, but the availability of the technique in farm animals has not yet been examined. In the present study, we tested the potential use of an acceleration index, overall dynamic body acceleration (ODBA), as a new proxy for estimating the energy expenditure of grazing farm animals (cattle, goats and sheep) at pasture with the simultaneous evaluation of a conventional proxy, heart rate. Body accelerations in three axes and heart rate for cows (n = 8, two breeds), goats (n = 6) and sheep (n = 5) were recorded, and the effect of ODBA calculated from the body accelerations on heart rate was analyzed. In addition, the effects of the two other activity indices, the number of steps and vectorial dynamic body acceleration (VeDBA), on heart rate were also investigated. The results of the comparison among three activity indices indicated that ODBA was the best predictor for heart rate. Although the relationship between ODBA and heart rate was different between the groups of species and breeds and between individuals (Panimals, and the results indicated that ODBA is a good proxy for estimating the energy expenditure of grazing farm animals across species and breeds. The utility and simplicity of the procedure with acceleration loggers could make the accelerometry technique a worthwhile option in field research and commercial farm use. PMID:26030931

  12. Heart rate variability based on risk stratification for type 2 diabetes mellitus.

    Science.gov (United States)

    Silva-E-Oliveira, Julia; Amélio, Pâmela Marina; Abranches, Isabela Lopes Laguardia; Damasceno, Dênis Derly; Furtado, Fabianne

    2017-01-01

    To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score and was classified as low risk (n=26), slightly elevated risk (n=41), moderate risk (n=27) and high risk (n=32). To measure heart rate variability, a heart-rate monitor Polar S810i® was employed to obtain RR series for each individual, at rest, for 5 minutes, followed by analysis of linear and nonlinear indexes. The groups at higher risk of type 2 diabetes mellitus had significantly lower linear and nonlinear heart rate variability indexes. The individuals at high risk for type 2 diabetes mellitus have lower heart rate variability. Avaliar a variabilidade da frequência cardíaca em adultos com diferentes níveis de risco para diabetes mellitus tipo 2. O grau de risco para diabetes mellitus tipo 2 de 130 participantes (41 homens) foi avaliado pelo questionário Finnish Diabetes Risk Score. Os participantes foram classificados em baixo risco (n=26), risco levemente elevado (n=41), risco moderado (n=27) e alto risco (n=32). Para medir a variabilidade da frequência cardíaca, utilizou-se o frequencímetro Polar S810i® para obter séries de intervalo RR para cada indivíduo, em repouso, durante 5 minutos; posteriormente, realizou-se análise por meio de índices lineares e não-lineares. O grupo com maior risco para diabetes mellitus tipo 2 teve uma diminuição significante nos índices lineares e não-lineares da variabilidade da frequência cardíaca. Os resultados apontam que indivíduos com risco alto para diabetes mellitus tipo 2 tem menor variabilidade da frequência cardíaca. To evaluate heart rate variability among adults with different risk levels for type 2 diabetes mellitus. The risk for type 2 diabetes mellitus was assessed in 130 participants (89 females) based on the questionnaire Finnish Diabetes Risk Score

  13. Experimental protocol to assess the tourism vehicles accessibility based on heart rate and access time measurements

    Energy Technology Data Exchange (ETDEWEB)

    Alcala Fazio, E.; Alvarez Fernandez, N.

    2016-07-01

    The objective of the Project is to define an experimental protocol for the accessibility assessment of the transport vehicles, by analysing the evolution of the effort and time variables consumed by a target group –Persons of Reduced Mobility (PMRs). This protocol consisted in tests of accessibility on a sample of 6 passenger cars (class M1) by 8 elderly people carrying a heart rate monitor, and whose access manoeuvres were recorded by video cameras. Based on the Hilloskorpi et al. [1] model and by developing a method of truncation of the heart rate (HR) tests records - eliminating the component of the work biologically needed by the organism to keep its basal metabolic rate from the work each person performed – it was possible to evaluate how much energy each individual invested in each access manoeuver. Immediately after each test, and after the whole round of vehicles, each participant was surveyed for a subjective assessment of the difficulty of accessing to the cars. According to each of the above results, the HR objective measurements and the subjective opinion about the ease of access experienced by each individual, the vehicles were ranked by order of accessibility to the front and rear seats. The result of both rankings showed the orders of the similar vehicles, the potential of the method and a fair closeness between its results and the subjective, but real and unequivocal, judgments of the participants. (Author)

  14. Determination of Hemodynamic Changes on Heart Rate for Assessment of Orthostatic Intolerance in Older People

    Energy Technology Data Exchange (ETDEWEB)

    Hortelano Rubio, M.; Reilly, R.B.; Cervigón Abad, R.

    2016-07-01

    Introduction.- The aim of our study was to assess the hemodynamic changes that occur in symptomatic Orthostatic Intolerance (OI) patients, at the starting of exercise and recovery stages during six minutes walking distance test. Materials.- We analysed 65 older subjects, of whom 42 were women. The participants were carried out the Active Stand Protocol. The records were divided into: Phase 1 (pre-exercise), Phase 2 (starting of exercise), Phase 3 (active), Phase 4 (recovery) and Phase 5 (prost-exercise). Methods.- The averages and differences of heart rate (HR) between Phase 1, Phase 3 and Phase 5 were calculated. In the same way, duration before stabilization from passive to active stages (Phase 2) and from active to passive stages (Phase 4) were calculated. The máximum and mínimum values achieved in these time series and the difference between these values were also calculated. Results.- Results showed that the symptomatic OI patients employed more time to reach the active phase tan the asymptomatic OI participants. Moreover, the symptomatic OI participants showed higher mínimum heart rate values at the starting of exercise and recovery stages. However, the asymptomatic OI group illustrated a higher difference between the máximum and mínimum heart rate values in these stages with a significance p=0.003 and p=0.007, respectivecly. Conclusion.- This study provides important information on hemodynamic parameters and can be helpful for description of the hemodynamic changes that occur during OI. (Author)

  15. Abnormal heart rate recovery and deficient chronotropic response after submaximal exercise in young Marfan syndrome patients.

    Science.gov (United States)

    Peres, Paulo; Carvalho, Antônio C; Perez, Ana Beatriz A; Medeiros, Wladimir M

    2016-10-01

    Marfan syndrome patients present important cardiac structural changes, ventricular dysfunction, and electrocardiographic changes. An abnormal heart rate response during or after exercise is an independent predictor of mortality and autonomic dysfunction. The aim of the present study was to compare heart rate recovery and chronotropic response obtained by cardiac reserve in patients with Marfan syndrome subjected to submaximal exercise. A total of 12 patients on β-blocker therapy and 13 off β-blocker therapy were compared with 12 healthy controls. They were subjected to submaximal exercise with lactate measurements. The heart rate recovery was obtained in the first minute of recovery and corrected for cardiac reserve and peak lactate concentration. Peak heart rate (141±16 versus 155±17 versus 174±8 bpm; p=0.001), heart rate reserve (58.7±9.4 versus 67.6±14.3 versus 82.6±4.8 bpm; p=0.001), heart rate recovery (22±6 versus 22±8 versus 34±9 bpm; p=0.001), and heart rate recovery/lactate (3±1 versus 3±1 versus 5±1 bpm/mmol/L; p=0.003) were different between Marfan groups and controls, respectively. All the patients with Marfan syndrome had heart rate recovery values below the mean observed in the control group. The absolute values of heart rate recovery were strongly correlated with the heart rate reserve (r=0.76; p=0.001). Marfan syndrome patients have reduced heart rate recovery and chronotropic deficit after submaximal exercise, and the chronotropic deficit is a strong determinant of heart rate recovery. These changes are suggestive of autonomic dysfunction.

  16. Heart rate and activity profile for young female soccer players

    OpenAIRE

    Barbero Álvarez, José Carlos; Gómez López, Maite; Barbero Álvarez, Verónica; Granda Vera, Juan; Castagna, Carlo

    2008-01-01

    The physical and physiological demands of high-level male soccer have been studied extensively, while few studies have investigated the demands placed on females during match-play, however, there is no information available about the heart rate and activity profile of young female soccer players during match play. Therefore, the aim of this study was to examine cardiovascular (heart-rates HR) and physical demands of young female soccer players during a match. Players were observed during a fr...

  17. Increased heart rate variability but normal resting metabolic rate in hypocretin/orexin-deficient human narcolepsy.

    NARCIS (Netherlands)

    Fronczek, R.; Overeem, S.; Reijntjes, R.; Lammers, G.J.; Dijk, J.G.M.; Pijl, H.

    2008-01-01

    STUDY OBJECTIVES: We investigated autonomic balance and resting metabolic rate to explore their possible involvement in obesity in hypocretin/orexin-deficient narcoleptic subjects. METHODS: Resting metabolic rate (using indirect calorimetry) and variability in heart rate and blood pressure were

  18. A Comparative Study on Fetal Heart Rates Estimated from Fetal Phonography and Cardiotocography

    Directory of Open Access Journals (Sweden)

    Emad A. Ibrahim

    2017-10-01

    Full Text Available The aim of this study is to investigate that fetal heart rates (fHR extracted from fetal phonocardiography (fPCG could convey similar information of fHR from cardiotocography (CTG. Four-channel fPCG sensors made of low cost (<$1 ceramic piezo vibration sensor within 3D-printed casings were used to collect abdominal phonogram signals from 20 pregnant mothers (>34 weeks of gestation. A novel multi-lag covariance matrix-based eigenvalue decomposition technique was used to separate maternal breathing, fetal heart sounds (fHS and maternal heart sounds (mHS from abdominal phonogram signals. Prior to the fHR estimation, the fPCG signals were denoised using a multi-resolution wavelet-based filter. The proposed source separation technique was first tested in separating sources from synthetically mixed signals and then on raw abdominal phonogram signals. fHR signals extracted from fPCG signals were validated using simultaneous recorded CTG-based fHR recordings.The experimental results have shown that the fHR derived from the acquired fPCG can be used to detect periods of acceleration and deceleration, which are critical indication of the fetus' well-being. Moreover, a comparative analysis demonstrated that fHRs from CTG and fPCG signals were in good agreement (Bland Altman plot has mean = −0.21 BPM and ±2 SD = ±3 with statistical significance (p < 0.001 and Spearman correlation coefficient ρ = 0.95. The study findings show that fHR estimated from fPCG could be a reliable substitute for fHR from the CTG, opening up the possibility of a low cost monitoring tool for fetal well-being.

  19. Vigorous physical activity predicts higher heart rate variability among younger adults.

    Science.gov (United States)

    May, Richard; McBerty, Victoria; Zaky, Adam; Gianotti, Melino

    2017-06-14

    Baseline heart rate variability (HRV) is linked to prospective cardiovascular health. We tested intensity and duration of weekly physical activity as predictors of heart rate variability in young adults. Time and frequency domain indices of HRV were calculated based on 5-min resting electrocardiograms collected from 82 undergraduate students. Hours per week of both moderate and vigorous activity were estimated using the International Physical Activity Questionnaire. In regression analyses, hours of vigorous physical activity, but not moderate activity, significantly predicted greater time domain and frequency domain indices of heart rate variability. Adjusted for weekly frequency, greater daily duration of vigorous activity failed to predict HRV indices. Future studies should test direct measurements of vigorous activity patterns as predictors of autonomic function in young adulthood.

  20. Heart rate asymmetry follows the inspiration/expiration ratio in healthy volunteers

    International Nuclear Information System (INIS)

    Klintworth, Anne; Ajtay, Zénó; Paljunite, Alina; Szabados, Sándor; Hejjel, László

    2012-01-01

    Heart rate asymmetry (HRA) quantifies the uneven distribution of points above and below the identity-line in a Poincaré plot of RR-intervals. The authors investigated if HRA could be influenced by the inspiration/expiration ratio. Healthy volunteers (n = 18) were studied in the supine position at 4.5 s metronome breathing. ECG and breathing signals were recorded for 360 s at each breathing pattern: inspiration controlled, inspiration/expiration controlled (1:2, 1:1, 2:1 ratio), inspiration controlled again. Time domain, frequency domain and Poincaré plot heart rate variability (HRV) analysis with Porta's and Guzik's indices were performed on 300 s tachograms. There were no statistically significant differences in time domain, frequency domain and standard Poincaré plot parameters during the various breathing patterns, whereas Porta's and Guzik's indices significantly rose at 1:1 and 2:1 compared to physiological 1:2 breathing. There were no significant differences in the HRA parameters between the first and the last runs. In our population the inspiration/expiration ratio significantly influenced HRA, but not standard HRV parameters. Positive correlation of Guzik's and Porta's index reflects reciprocal changes of the number of points and their dispersion in the accelerating and decelerating sets of RR-intervals. HRA-analysis can be a promising method for investigating cardiovascular regulation/health particularly with further spreading of wearable monitors. (paper)

  1. Fetal QRS detection and heart rate estimation: a wavelet-based approach

    International Nuclear Information System (INIS)

    Almeida, Rute; Rocha, Ana Paula; Gonçalves, Hernâni; Bernardes, João

    2014-01-01

    Fetal heart rate monitoring is used for pregnancy surveillance in obstetric units all over the world but in spite of recent advances in analysis methods, there are still inherent technical limitations that bound its contribution to the improvement of perinatal indicators. In this work, a previously published wavelet transform based QRS detector, validated over standard electrocardiogram (ECG) databases, is adapted to fetal QRS detection over abdominal fetal ECG. Maternal ECG waves were first located using the original detector and afterwards a version with parameters adapted for fetal physiology was applied to detect fetal QRS, excluding signal singularities associated with maternal heartbeats. Single lead (SL) based marks were combined in a single annotator with post processing rules (SLR) from which fetal RR and fetal heart rate (FHR) measures can be computed. Data from PhysioNet with reference fetal QRS locations was considered for validation, with SLR outperforming SL including ICA based detections. The error in estimated FHR using SLR was lower than 20 bpm for more than 80% of the processed files. The median error in 1 min based FHR estimation was 0.13 bpm, with a correlation between reference and estimated FHR of 0.48, which increased to 0.73 when considering only records for which estimated FHR > 110 bpm. This allows us to conclude that the proposed methodology is able to provide a clinically useful estimation of the FHR. (paper)

  2. Estimating Energy Expenditure from Heart Rate in Older Adults: A Case for Calibration

    OpenAIRE

    Schrack, Jennifer A.; Zipunnikov, Vadim; Goldsmith, Jeff; Bandeen-Roche, Karen; Crainiceanu, Ciprian M.; Ferrucci, Luigi

    2014-01-01

    Background Accurate measurement of free-living energy expenditure is vital to understanding changes in energy metabolism with aging. The efficacy of heart rate as a surrogate for energy expenditure is rooted in the assumption of a linear function between heart rate and energy expenditure, but its validity and reliability in older adults remains unclear. Objective To assess the validity and reliability of the linear function between heart rate and energy expenditure in older adults using diffe...

  3. Effect of propranolol on heart rate variability in hyperthyroidism.

    Science.gov (United States)

    Tankeu, Aurel T; Azabji-Kenfack, Marcel; Nganou, Chris-Nadège; Ngassam, Eliane; Kuate-Mfeukeu, Liliane; Mba, Camille; Dehayem, Mesmin Y; Mbanya, Jean-Claude; Sobngwi, Eugene

    2018-02-22

    We aimed to determine the effect of propanolol on heart rate variability (HRV) in hyperthyroidism before antithyroid treatment. This was a before and after study, on ten patients presenting overt hyperthyroidism naïve to treatment. In each patient, a resting electrocardiogram was done followed by estimation of cardiac autonomic dysfunction during five maneuvers (Ewing battery tests). Long term HRV measurement was done using 24 h ambulatory electrocardiographic recording. This automatically provided estimation of HRV using SDNN and RMSSD index, LF, HF, and HF/LF ratio. After baseline investigations, 40 mg of propanolol was given twice a day for 3 days and same parameters were measured after 72 h of treatment. Our patients were aged 40 ± 10 years. Propanolol significantly reduced RR and HR interval (669 ms vs 763 ms and 91 vs 79 bpm; p hyperthyroidism. Trial registration NCT03393728 "Retrospectively registered".

  4. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio [Tohoku Univ., Sendai (Japan). School of Medicine

    1998-11-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ({sup 123}I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of {sup 123}I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of {sup 123}I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). {sup 123}I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of {sup 123}I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the {sup 123}I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  5. Evaluation of therapy for dilated cardiomyopathy with heart failure by iodine-123 metaiodobenzyl-guanidine imaging. Comparison with heart rate variability power spectral analysis

    International Nuclear Information System (INIS)

    Li, Shou-lin; Ikeda, Jun; Takita, Tamotsu; Sekiguchi, Yohei; Demachi, Jun; Chikama, Hisao; Goto, Atsushi; Shirato, Kunio

    1998-01-01

    The relationship between the myocardial uptake of iodine-123 metaiodobenzylguanidine ( 123 I-MIBG) and heart rate variability parameters has not been determined. This study determined the relationship between the change in myocardial uptake of 123 I-MIBG and improvement in left ventricular function after treatment, to determine the usefulness of 123 I-MIBG imaging to assess the effect of therapy on heart failure due to dilated cardiomyopathy (DCM). 123 I-MIBG imaging and power spectral analysis of heart rate variability were performed before and after treatment in 17 patients with heart failure due to DCM. The following parameters were compared before and after treatment: New York Heart Association (NYHA) functional class, radiographic cardiothoracic ratio (CTR), blood pressure, echocardiographic data (left ventricular end-systolic (LVDs) and end-diastolic (LVDd) diameters, left ventricular ejection fraction (LVEF)), plasma concentrations of norepinephrine and epinephrine, heart rate variability power spectral analysis data (mean low frequency (MLF) and high frequency power (MHF)) and the myocardium to mediastinum activity ratio (MYO/M) obtained in early and late images, and washout rate calculated by anterior planar imaging of 123 I-MIBG. The NYHA functional class, LVEF, LVDs, CTR, MLF and MHF improved after treatment. Early MYO/M and late MYO/M improved after treatment. The rate of increase in late MYO/M was positively correlated with the rate of improvement of LVEF after treatment. Furthermore, the late MYO/M was negatively correlated with MLF. Washout rate revealed no correlation with hemodynamic parameters. These findings suggest that late MYO/M is more useful than washout rate to assess the effect of treatment on heart failure due to DCM. Furthermore, the 123 I-MIBG imaging and heart rate variability parameters are useful to assess the autonomic tone in DCM with heart failure. (author)

  6. Identification and Progression of Heart Disease Risk Factors in Diabetic Patients from Longitudinal Electronic Health Records

    Directory of Open Access Journals (Sweden)

    Jitendra Jonnagaddala

    2015-01-01

    Full Text Available Heart disease is the leading cause of death worldwide. Therefore, assessing the risk of its occurrence is a crucial step in predicting serious cardiac events. Identifying heart disease risk factors and tracking their progression is a preliminary step in heart disease risk assessment. A large number of studies have reported the use of risk factor data collected prospectively. Electronic health record systems are a great resource of the required risk factor data. Unfortunately, most of the valuable information on risk factor data is buried in the form of unstructured clinical notes in electronic health records. In this study, we present an information extraction system to extract related information on heart disease risk factors from unstructured clinical notes using a hybrid approach. The hybrid approach employs both machine learning and rule-based clinical text mining techniques. The developed system achieved an overall microaveraged F-score of 0.8302.

  7. Reliability of heart rate mobile apps in young healthy adults: exploratory study and research directions

    Directory of Open Access Journals (Sweden)

    Maria Parpinel

    2017-06-01

    Full Text Available Background: Recently, a number of smartphone apps appeared that allow for heart rate measurements basing on the photoplethysmography principle. In fact, almost every smartphone now has a camera with flash that could be used for that. Some studies appeared on the reliability of some of those apps, with heterogeneous results. Objectives: The present study aims at adding up evidence in particular during physical activity, by comparing 3 apps on two different platforms (IOs and Android, on a broad range of heart rates. As gold standard, heart rate has been measured with a traditional heart rate monitor. Results: The results suggest that heart rate apps might be used for measuring heart rate for fitness aims for many individuals, but further research is needed to i analyse influence of smartphone features; ii identify personal factors hindering measurements, and iii verify reliability on different measurement sites.

  8. Heart rate profiles and energy cost of locomotion during cross-country skiing races.

    Science.gov (United States)

    Mognoni, P; Rossi, G; Gastaldelli, F; Canclini, A; Cotelli, F

    2001-07-01

    The purpose of this study was to compare heart rate responses and speed in two cross-country skiing races, which were run by seven male and seven female subjects by using classic and free style. Heart rates and skiing velocities were analyzed over flat, uphill and downhill sections, which were run from one to three times. Heart rates were higher in uphill sections than in flat sections; a steady-state heart rate was never reached in the downhill section. When the same uphill section was repeated, the heart rate tended to increase but the speed to decrease. Oxygen uptake (VO2) was calculated from heart rate:VO2 ratio, measured during uphill walking with the aid of poles. The mean (SD) energy cost of locomotion (i.e., the ratio between net VO2 and speed) was 162.1 (9.4) ml.km(-1).kg(-1) and 147.7 (7.1) ml.km(-1).kg(-1) when male subjects ran the flat section after first downhill by using classic and free style, respectively. Females had lower values for VO2 and speed, but similar energy costs. In general, the variability of the energy cost of locomotion in skiers of a similar competitive level is of the same order as that found in uphill walking on a treadmill.

  9. Heart rate calculation from ensemble brain wave using wavelet and Teager-Kaiser energy operator.

    Science.gov (United States)

    Srinivasan, Jayaraman; Adithya, V

    2015-01-01

    Electroencephalogram (EEG) signal artifacts are caused by various factors, such as, Electro-oculogram (EOG), Electromyogram (EMG), Electrocardiogram (ECG), movement artifact and line interference. The relatively high electrical energy cardiac activity causes EEG artifacts. In EEG signal processing the general approach is to remove the ECG signal. In this paper, we introduce an automated method to extract the ECG signal from EEG using wavelet and Teager-Kaiser energy operator for R-peak enhancement and detection. From the detected R-peaks the heart rate (HR) is calculated for clinical diagnosis. To check the efficiency of our method, we compare the HR calculated from ECG signal recorded in synchronous with EEG. The proposed method yields a mean error of 1.4% for the heart rate and 1.7% for mean R-R interval. The result illustrates that, proposed method can be used for ECG extraction from single channel EEG and used in clinical diagnosis like estimation for stress analysis, fatigue, and sleep stages classification studies as a multi-model system. In addition, this method eliminates the dependence of additional synchronous ECG in extraction of ECG from EEG signal process.

  10. Short-term versus long-term heart rate variability in ischemic cardiomyopathy risk stratification

    Directory of Open Access Journals (Sweden)

    Andreas eVoss

    2013-12-01

    Full Text Available In industrialized countries with aging populations, heart failure affects 0.3%-2% of the general population. The investigation of 24h-ECG recordings revealed the potential of nonlinear indices of heart rate variability (HRV for enhanced risk stratification in patients with ischemic heart failure (IHF. However, long-term analyses are time-consuming, expensive and delay the initial diagnosis. The objective of this study was to investigate whether 30min short-term HRV analysis is sufficient for comparable risk stratification in IHF in comparison to 24h-HRV analysis. From 256 IHF patients (221 at low risk (IHFLR and 35 at high risk (IHFHR a 24h beat-to-beat time series b the first 30min segment c the 30min most stationary day segment and d the 30min most stationary night segment were investigated. We calculated linear (time and frequency domain and nonlinear HRV analysis indices. Optimal parameter sets for risk stratification in IHF were determined for 24 hours and for each 30min segment by applying discriminant analysis on significant clinical and non-clinical indices. Long- and short-term HRV indices from frequency domain and particularly from nonlinear dynamics revealed high univariate significances (p

  11. 256-slice CT coronary angiography in atrial fibrillation: The impact of mean heart rate and heart rate variability on image quality

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Liang-Kuang [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan (China); College of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China); Hsu, Shih-Ming [Department of Biomedical Imaging and Radiological Science, China Medical University, Taichung, Taiwan (China); Mok, Greta S.P. [Department of Electrical and Electronics Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Law, Wei-Yip; Lu, Kun-Mu [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan (China); Yang, Ching-Ching, E-mail: g39220003@yahoo.com.tw [Department of Radiological Technology, Tzu Chi College of Technology, 880, Sec.2, Chien-kuo Rd. Hualien 970, Taiwan (China); Wu, Tung-Hsin, E-mail: tung@ym.edu.tw [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, 155 Li-Nong St., Sec. 2, Taipei 112, Taiwan (China)

    2011-08-21

    Objective: The aim of this study was to evaluate the image quality of 256-MDCT in atrial fibrillation and to compare the findings with those among patients in sinus rhythm. Materials: All reconstructed images were evaluated by two independent experienced readers blinded to patient information, heart rate, and ECG results to assess the diagnostic quality of images of the coronary artery segments using axial images, multi-planar reformations, maximum intensity projections, and volume rendering technique. Results: No statistical significance was detected in terms of the overall image quality between patients in sinus rhythm and with atrial fibrillation. Pearson's correlation analysis showed no significant association between image quality and mean heart rate no matter for patients in sinus rhythm or with atrial fibrillation. Similarly, there was no correlation between image quality and heart rate variability for either patients in sinus rhythm or with atrial fibrillation. Our results showed that the optimal reconstruction window depends on patient's HR, and the pattern for patients in atrial fibrillation is similar to that obtained from non-atrial fibrillation patients. Conclusion: This study shows the potential of using 256-MDCT coronary angiography in patients with atrial fibrillation. Our results suggest that when appropriate reconstruction timing window is applied, patients with atrial fibrillation do not have to be excluded from MDCT coronary angiographic examinations.

  12. 256-slice CT coronary angiography in atrial fibrillation: The impact of mean heart rate and heart rate variability on image quality

    International Nuclear Information System (INIS)

    Chen, Liang-Kuang; Hsu, Shih-Ming; Mok, Greta S.P.; Law, Wei-Yip; Lu, Kun-Mu; Yang, Ching-Ching; Wu, Tung-Hsin

    2011-01-01

    Objective: The aim of this study was to evaluate the image quality of 256-MDCT in atrial fibrillation and to compare the findings with those among patients in sinus rhythm. Materials: All reconstructed images were evaluated by two independent experienced readers blinded to patient information, heart rate, and ECG results to assess the diagnostic quality of images of the coronary artery segments using axial images, multi-planar reformations, maximum intensity projections, and volume rendering technique. Results: No statistical significance was detected in terms of the overall image quality between patients in sinus rhythm and with atrial fibrillation. Pearson's correlation analysis showed no significant association between image quality and mean heart rate no matter for patients in sinus rhythm or with atrial fibrillation. Similarly, there was no correlation between image quality and heart rate variability for either patients in sinus rhythm or with atrial fibrillation. Our results showed that the optimal reconstruction window depends on patient's HR, and the pattern for patients in atrial fibrillation is similar to that obtained from non-atrial fibrillation patients. Conclusion: This study shows the potential of using 256-MDCT coronary angiography in patients with atrial fibrillation. Our results suggest that when appropriate reconstruction timing window is applied, patients with atrial fibrillation do not have to be excluded from MDCT coronary angiographic examinations.

  13. Effect of music tempo on exercise performance and heart rate among young adults.

    Science.gov (United States)

    Thakare, Avinash E; Mehrotra, Ranjeeta; Singh, Ayushi

    2017-01-01

    Music captures attention, triggers a range of emotions, alters or regulates mood, increases work output, heightens arousal, induces states of higher functioning, reduces inhibitions and encourages rhythmic movement. Music has ergo-genic effect as well, it increases exercise performance, delays fatigue and increases performance and endurance, power and strength. Our study tried to evaluate the effect of music on exercise performance in young untrained subjects. In this study, we tested the effect of music on sub maximal exercise performance time duration in young adults. 25 Male and 25 females were subjected to standard submaximal exercise with and without music. Resting HR and Max. HR during exercise and the exercise time duration was recorded. Total exercise duration in whole group with music (37.12 ± 16.26** min) was significantly greater than exercise duration without music (22.48 ± 10.26 min). Males (42.4 ± 15.6** min) outperformed significantly better than females (31.84 ± 15.48 min). Also, we observed statistically significant higher values of Maximal heart rate with music than without music. But there was no significant correlation between duration of exercise, music and change in Heart rate. We can conclude that Music increases duration of exercise in both sexes and hence endurance.

  14. Estimating the cost of mental loading in a bimodal divided-attention task: Combining reaction time, heart-rate variability and signal-detection theory

    Science.gov (United States)

    Casper, Patricia A.; Kantowitz, Barry H.

    1988-01-01

    Multiple approaches are necessary for understanding and measuring workload. In particular, physiological systems identifiable by employing cardiac measures are related to cognitive systems. One issue of debate in measuring cardiac output is the grain of analysis used in recording and summarizing data. Various experiments are reviewed, the majority of which were directed at supporting or contradicting Lacey's intake-rejection hypothesis. Two of the experiments observed heart rate in operational environments and found virtually no changes associated with mental load. The major problems facing researchers using heart rate variability, or sinus arrhthmia, as a dependent measure have been associated with valid and sensitive scoring and preventing contamination of observed results by influences unrelated to cognition. Spectral analysis of heart rate variability offers two useful procedures: analysis from the time domain and analysis from the frequency domain. Most recently, data have been collected in a divided attention experiment, the performance measures and cardiac measures of which are detailed.

  15. Robust efficient estimation of heart rate pulse from video

    Science.gov (United States)

    Xu, Shuchang; Sun, Lingyun; Rohde, Gustavo Kunde

    2014-01-01

    We describe a simple but robust algorithm for estimating the heart rate pulse from video sequences containing human skin in real time. Based on a model of light interaction with human skin, we define the change of blood concentration due to arterial pulsation as a pixel quotient in log space, and successfully use the derived signal for computing the pulse heart rate. Various experiments with different cameras, different illumination condition, and different skin locations were conducted to demonstrate the effectiveness and robustness of the proposed algorithm. Examples computed with normal illumination show the algorithm is comparable with pulse oximeter devices both in accuracy and sensitivity. PMID:24761294

  16. Mental load, heart rate and heart rate variability.

    NARCIS (Netherlands)

    Blitz, P.S.; Hoogstraten, J.; Mulder, G.

    1970-01-01

    "Several investigators have shown that diminished sinus arrhythmia can be seen as an indication of increased mental load. The present experiment deals with the influence of different levels of mental load, operationalized as the number of binary choices per minute, on the regularity of the heart

  17. Hypnosis in the Treatment of Major Depression: An Analysis of Heart Rate Variability.

    Science.gov (United States)

    Chen, Xiuwen; Yang, Rongqian; Ge, Lulu; Luo, Jie; Lv, Ruixue

    2017-01-01

    Hypnosis is an adjuvant treatment of major depression (MD). Heart rate variability (HRV) can assess the autonomic nervous system, which is associated with MD, and HRV is decreased in MD patients. There is a lack of research on HRV changes before, during, and after the use of hypnosis in MD patients. A total of 21 MD patients participated in this study, and 5-minute electrocardiograms were recorded before, during, and after hypnosis. Compared with the prehypnotic condition, HRV parameters significantly (p hypnosis treatment should bring some functional improvement to the autonomic nervous system. HRV is potentially a useful tool that quantifies the physiological impact of hypnosis treatment in MD patients.

  18. Electrocardiogram application based on heart rate variability ontology and fuzzy markup language

    NARCIS (Netherlands)

    Wang, M.-H.; Lee, C.-S.; Acampora, G.; Loia, V.; Gacek, A.; Pedrycz, W.

    2011-01-01

    The electrocardiogram (ECG) signal is adopted extensively as a low-cost diagnostic procedure to provide information concerning the healthy status of the heart. Heart rate variability (HRV) is a physiological phenomenon where the time interval between heart beats varies. It is measured by the

  19. Exploratory multivariate analysis of the effect of fatty fish consumption and medicinal use on heart rate and heart rate variability data

    Directory of Open Access Journals (Sweden)

    Bjorn eGrung

    2015-02-01

    Full Text Available The overall aim of the present study was to explore the relationship between medicinal use and fatty fish consumption on heart rate variability (HRV and heart rate (HR in a group of forensic inpatients on a variety of medications. A total of 49 forensic inpatients, randomly assigned to a fish group (n=27 or a control group (n=22 were included in the present study. Before and by the end of the food intervention period HR and HRV were measured during an experimental test procedure. An additional aim of this paper is to show how multivariate data analysis can highlight differences and similarities between the groups, thus being a valuable addition to traditional statistical hypothesis testing. The results indicate that fish consumption may have a positive effect on both HR and HRV regardless of medication, but that the influence of medication is strong enough to mask the true effect of fish consumption. Without correcting for medication, the fish group and control group become indistinguishable (p = 0.0794, Cohen’s d = 0.60. The effect of medication is demonstrated by establishing a multivariate regression model that estimates HR and HRV in a recovery phase based on HR and HRV data recorded during psychological tests. The model performance is excellent for HR data, but yields poor results for HRV when employed on participants undergoing the more severe medical treatments. This indicates that the HRV behavior of this group is very different from that of the participants on no or lower level of medication. When focusing on the participants on a constant medication regime, a substantial improvement in HRV and HR for the fish group compared to the control group is indicated by a principal component analysis and t tests (p = 0.00029, Cohen’s d = 2.72. In a group of psychiatric inpatients characterized by severe mental health problems consuming different kinds of medication, the fish diet improved HR and HRV, indices of both emotional regulation and

  20. Heart Rates of Elementary Physical Education Students during the Dancing Classrooms Program

    Science.gov (United States)

    Nelson, Larry; Evans, Melissa; Guess, Wendy; Morris, Mary; Olson, Terry; Buckwalter, John

    2011-01-01

    We examined how different types of dance activities, along with their duration, influenced heart rate responses among fifth-grade physical education students (N = 96) who participated in the Dancing Classrooms program. Results indicated that the overall Dancing Classrooms program elicits a moderate cardiovascular heart rate response (M = 124.4…

  1. Heart Rate Variability in Patients with Chronic Obstructive Pulmonary Disease Treated by Noninvasive Mechanic Ventilation

    Directory of Open Access Journals (Sweden)

    Zekeriya Küçükdurmaz

    2011-08-01

    Full Text Available Aims: This study aimed to investigate heart rate variability (HRV of patients with severe COPD who are treated by noninvasive mechanic ventilation (NIMV.Patients and Method: Twenty-seven patient (58±8 years, 9 F with severe COPD treated by nocturnal NIMV at home and 23 sex and age matched volunteers (56±8 years, 11 F who has not dyspnea as a control group recruited in the study. Subjects underwent spirometry, blood gas analysis, transthoracic echocardiography, 24 hours ambulatory ECG analysis. Time domain HRV analysis performed from ambulatory ECG records. Results: 52% of patients at NYHA functional class II, 36% at class III, and 12% at class IV when they have been treated by NIMV. Groups were similar for age and sex (p>0.05 for both. Heart rates of patients were higher significantly than controls’ (p0.05. But, systolic pulmonary pressures were higher of COPD group (p<0.01. 24 hours heart rate was higher, and standard deviation of normal R-R intervals (SDNN 24 hours, SDNN night, SDNN day, SDNN index (SDNNI and standard deviation of mean R-R intervals (SDANNI values were lower in COPD group significantly. SDNN was inversely correlated with duration of daily NIMV usage, intensive care unit administration and entubation rate and PaCO2. SDNNI was inversely correlated with functional class, duration of daily NIMV usage, intensive care unit administration rate and PaCO2. Else, SDNNI was correlated with predicted forced vital capacity % (FVC% and predicted forced expiratory volume at 1 second % (FEV1%.Conclusion: Time domain HRV decreases in patients with severe COPD. Decrease is correlated with severity of disease, and it presents in despite of the chronic nocturnal NIMV application. These patients have high risk for cardiovascular morbidity and mortality and should be monitored and manegement for cardiovascular events.

  2. Heart rate recovery in elite Spanish male athletes.

    Science.gov (United States)

    Peinado, A B; Benito, P J; Barriopedro, M; Lorenzo, I; Maffulli, N; Calderón, F J

    2014-06-01

    During postexercise recovery, heart rate (HR) initially falls rapidly, followed by a period of slower decrease, until resting values are reached. The aim of the present work was to examine the differences in the recovery heart rate (RHR) between athletes engaged in static and dynamic sports. The study subjects were 294 federated sportsmen competing at the national and international level in sports classified using the criteria of Mitchell et al. as either prevalently static (N.=89) or prevalently dynamic (N.=205). Within the dynamic group, the subjects who practised the most dynamic sports were assigned to further subgroups: triathlon (N.=20), long distance running (N.=58), cycling (N.=28) and swimming (N.=12). All athletes were subjected to a maximum exertion stress test and their HR recorded at 1, 2, 3 and 4 min (RHR1,2,3,4) into the HR recovery period. The following indices of recovery (IR) were then calculated: IR1=(HRpeak-RHR1,2,3,4)/(HRmax-HRrest)*100, IR2=(HRpeak-RHR1,2,3,4)/(HRmax/HRpeak), and IR3=HRpeak-RHR1,2,3,4. The differences in the RHR and IR for the static and dynamic groups were examined using two way ANOVA. The RHR at minutes 2 (138.7±15.2 vs. 134.8±14.4 beats·min⁻¹) and 3 (128.5±15.2 vs. 123.3±14.4 beats·min⁻¹) were significantly higher for the static group (Group S) than the dynamic group (Group D), respectively. Significant differences were seen between Group D and S with respect to IR1 at minutes 1 (26.4±8.7 vs. 24.8±8.4%), 2 (43.8±8.1 vs. 41.5±7.8%), 3 (52.1±8.3 vs. 49.1±8%) and 4 (56.8±8.6 vs. 55.4±7.4%) of recovery. For IR2, significant differences were seen between the same groups at minutes 2 (59.7±12.5 vs. 55.9±10.8 beats·min⁻¹) and 3 (71.0±13.5 vs. 66.1±11.4 beats·min⁻¹) of recovery. Finally, for IR3, the only significant difference between Group D and S was recorded at minute 3 of recovery (72.2±12.5 vs. 66.2±11.5 beats·min⁻¹). This work provides information on RHR of a large population of elite

  3. Heart rate variability in the standing position reflects training adaptation in professional soccer players.

    Science.gov (United States)

    Ravé, Guillaume; Fortrat, Jacques-Olivier

    2016-08-01

    To show that heart rate variability (HRV) in the standing position better reflects the way in which athletes adapt to training in so-called intermittent sports than the indicator of resting parasympathetic tone usually employed in endurance sports. Twenty professional soccer players (intermittent sport) took part in a 5-week training session divided into three successive periods: "Warm-up", "Intensive training" and "Tapering". At the beginning and end of each of the three periods, a stand test was carried out and the heart rate was recorded, beat by beat (Polar Team 2). We analysed HRV to determine the indicator mostly used to demonstrate training adaptation in endurance sports (lnRMSSD supine, natural logarithm of root mean square of the successive differences) as well as indicators obtained by means of spectral analysis in both supine and standing position. A decrease in heart rate was observed in the supine position at rest during training (-5.2 ± 1.3 bpm) while lnRMSSD and spectral analysis indicators remained unchanged. The "Warm-up" caused an increase in spectral analysis total power in standing position which was further highlighted by "Tapering" (3.39 ± 0.09, 3.61 ± 0.08 and 3.65 ± 0.09 log ms(2), respectively). However, the autonomic changes are probably more complex than a change in autonomic activity or balance since spectral analysis autonomic indicators remained unchanged. HRV in the standing position could monitor training adaptation in intermittent sports contrary to the indicator usually employed in endurance sports. However, the significance of the HRV change in the standing position during training remains unclear.

  4. Heart Rate Measures of Flight Test and Evaluation

    National Research Council Canada - National Science Library

    Bonner, Malcolm A; Wilson, Glenn F

    2001-01-01

    .... Because flying is a complex task, several measures are required to derive the best evaluation. This article describes the use of heart rate to augment the typical performance and subjective measures used in test and evaluation...

  5. Comparison of carbon dioxide and argon euthanasia: effects on behavior, heart rate, and respiratory lesions in rats.

    Science.gov (United States)

    Burkholder, Tanya H; Niel, Lee; Weed, James L; Brinster, Lauren R; Bacher, John D; Foltz, Charmaine J

    2010-07-01

    In this study we compared rat (n = 16) responses to euthanasia with either gradual-fill CO(2) or rapid induction argon gas by evaluating the animals' heart rate via radiotelemetry, behavior, and vocalizations. We also evaluated the histologic effects of the gases. Rats were placed in an open test chamber 24 h before the start of the experiment. During baseline tests, rats were exposed to oxygen to evaluate the effects of the noise and movement of gas entering the chamber; 1 wk later, rats were euthanized by gas displacement with either 10%/min CO(2) or 50%/min argon gas. Rats tended to have higher heart rats and were more active during the baseline test, but these parameters were normal before the euthanasia experiment, suggesting that the rats had acclimated to the equipment. Heart rate, behavior, and ultrasonic vocalizations were recorded for 2 min after gas introduction in both groups. All rats appeared conscious throughout the test interval. The heart rates of rats exposed to argon did not change, whereas those of rats exposed to CO(2) declined significantly. Unlike those exposed to CO(2), rats euthanized with argon gas gasped and demonstrated seizure-like activity. There were no differences in the pulmonary lesions resulting from death by either gas. Our results suggest that argon as a sole euthanasia agent is aversive to rats. CO(2) using a 10%/min displacement may be less aversive than more rapid displacements. Future research investigating methods of euthanasia should allow sufficient time for the rats to acclimate to the test apparatus.

  6. Linear and nonlinear characteristics of heart rate time series in obesity and during weight-reduction surgery

    International Nuclear Information System (INIS)

    Alam, I; Morgan, J; Baxter, J; Lewis, M J

    2009-01-01

    Obesity is associated with abnormal cardiac regulation by the autonomic nervous system (ANS), this being reversed by weight loss. Bariatric (weight-reduction) surgery can induce substantial long-term weight reductions. This study compares the acute influence on ANS control of two different types of bariatric surgery involving laparascopic and open procedures. To distinguish between the cardiac influences of surgery and obesity, we perform the same analysis for laparascopic surgery in non-obese patients. Eight morbidly obese and five non-obese patients underwent surgery. Obese patients received either laparoscopic procedures (group A: n = 5, BMI = 44.3 ± 2.7 kg m 2 ) or open procedures (group B: n = 3, BMI = 55.2 ± 4.5 kg m 2 ) and non-obese patients received a laparoscopic procedure (group C: n = 5, BMI = 30.8 ± 5.8 kg m −2 ). Holter ECG was recorded and heart rate variability (HRV) was quantified together with measures of complexity (sample entropy) and structure (Hurst coefficient, scaling coefficient) of the heart rate data. Multifractal characteristics of heart rate data, not previously reported for obese patients, are also quantified and interpreted. Mixed model ANOVA was used to assess the magnitudes of each quantified variable, with surgical group and perioperative time as main factors. HRV measures were influenced only during anaesthesia (LFn increase: p = 0.009; HFn decrease: p = 0.033) and did not discriminate between patient groups. Multifractality was the only characteristic of heart rate data that discriminated between patient groups, being significantly (p < 0.001) greater in non-obese (group C) compared with obese patients (groups A and B, who had similar multifractal properties). Multifractality was also enhanced during anaesthesia (p = 0.028) but did not differ for other stages. We conclude that obesity per se rather than response to surgery is the cause of reduced multifractality. Reduced multifractality in obesity might reflect a diminished

  7. Office and 24-hour heart rate and target organ damage in hypertensive patients

    Directory of Open Access Journals (Sweden)

    García-García Ángel

    2012-03-01

    Full Text Available Abstract Background We investigated the association between heart rate and its variability with the parameters that assess vascular, renal and cardiac target organ damage. Methods A cross-sectional study was performed including a consecutive sample of 360 hypertensive patients without heart rate lowering drugs (aged 56 ± 11 years, 64.2% male. Heart rate (HR and its standard deviation (HRV in clinical and 24-hour ambulatory monitoring were evaluated. Renal damage was assessed by glomerular filtration rate and albumin/creatinine ratio; vascular damage by carotid intima-media thickness and ankle/brachial index; and cardiac damage by the Cornell voltage-duration product and left ventricular mass index. Results There was a positive correlation between ambulatory, but not clinical, heart rate and its standard deviation with glomerular filtration rate, and a negative correlation with carotid intima-media thickness, and night/day ratio of systolic and diastolic blood pressure. There was no correlation with albumin/creatinine ratio, ankle/brachial index, Cornell voltage-duration product or left ventricular mass index. In the multiple linear regression analysis, after adjusting for age, the association of glomerular filtration rate and intima-media thickness with ambulatory heart rate and its standard deviation was lost. According to the logistic regression analysis, the predictors of any target organ damage were age (OR = 1.034 and 1.033 and night/day systolic blood pressure ratio (OR = 1.425 and 1.512. Neither 24 HR nor 24 HRV reached statistical significance. Conclusions High ambulatory heart rate and its variability, but not clinical HR, are associated with decreased carotid intima-media thickness and a higher glomerular filtration rate, although this is lost after adjusting for age. Trial Registration ClinicalTrials.gov: NCT01325064

  8. Effect of Heart rate on Basketball Three-Point Shot Accuracy

    Directory of Open Access Journals (Sweden)

    Luca P. Ardigò

    2018-02-01

    Full Text Available The three-point shot (3S is a fundamental basketball skill used frequently during a game, and is often a main determinant of the final result. The aim of the study was to investigate the effect of different metabolic conditions, in terms of heart rates, on 3S accuracy (3S% in 24 male (Under 17 basketball players (age 16.3 ± 0.6 yrs. 3S performance was specifically investigated at different heart rates. All sessions consisted of 10 consecutive 3Ss from five different significant field spots just beyond the FIBA three-point line, i.e., about 7 m from the basket (two counter-clockwise “laps” at different heart rates: rest (0HR, after warm-up (50%HRMAX [50HR], and heart rate corresponding to 80% of its maximum value (80%HRMAX [80HR]. We found that 50HR does not significantly decrease 3S% (−15%, P = 0.255, while 80HR significantly does when compared to 0HR (−28%, P = 0.007. Given that 50HR does not decrease 3S% compared to 0HR, we believe that no preliminary warm-up is needed before entering a game in order to specifically achieve a high 3S%. Furthermore, 3S training should be performed in conditions of moderate-to-high fatigued state so that a high 3S% can be maintained during game-play.

  9. Application of overall dynamic body acceleration as a proxy for estimating the energy expenditure of grazing farm animals: relationship with heart rate.

    Science.gov (United States)

    Miwa, Masafumi; Oishi, Kazato; Nakagawa, Yasuhiro; Maeno, Hiromichi; Anzai, Hiroki; Kumagai, Hajime; Okano, Kanji; Tobioka, Hisaya; Hirooka, Hiroyuki

    2015-01-01

    Estimating the energy expenditure of farm animals at pasture is important for efficient animal management. In recent years, an alternative technique for estimating energy expenditure by measuring body acceleration has been widely performed in wildlife and human studies, but the availability of the technique in farm animals has not yet been examined. In the present study, we tested the potential use of an acceleration index, overall dynamic body acceleration (ODBA), as a new proxy for estimating the energy expenditure of grazing farm animals (cattle, goats and sheep) at pasture with the simultaneous evaluation of a conventional proxy, heart rate. Body accelerations in three axes and heart rate for cows (n = 8, two breeds), goats (n = 6) and sheep (n = 5) were recorded, and the effect of ODBA calculated from the body accelerations on heart rate was analyzed. In addition, the effects of the two other activity indices, the number of steps and vectorial dynamic body acceleration (VeDBA), on heart rate were also investigated. The results of the comparison among three activity indices indicated that ODBA was the best predictor for heart rate. Although the relationship between ODBA and heart rate was different between the groups of species and breeds and between individuals (Pheart rate (beats/min) = 147.263∙M-0.141 + 889.640∙M-0.179∙ODBA (g). Combining this equation with the previously reported energy expenditure per heartbeat, we estimated the energy expenditure of the tested animals, and the results indicated that ODBA is a good proxy for estimating the energy expenditure of grazing farm animals across species and breeds. The utility and simplicity of the procedure with acceleration loggers could make the accelerometry technique a worthwhile option in field research and commercial farm use.

  10. An open-source LabVIEW application toolkit for phasic heart rate analysis in psychophysiological research.

    Science.gov (United States)

    Duley, Aaron R; Janelle, Christopher M; Coombes, Stephen A

    2004-11-01

    The cardiovascular system has been extensively measured in a variety of research and clinical domains. Despite technological and methodological advances in cardiovascular science, the analysis and evaluation of phasic changes in heart rate persists as a way to assess numerous psychological concomitants. Some researchers, however, have pointed to constraints on data analysis when evaluating cardiac activity indexed by heart rate or heart period. Thus, an off-line application toolkit for heart rate analysis is presented. The program, written with National Instruments' LabVIEW, incorporates a variety of tools for off-line extraction and analysis of heart rate data. Current methods and issues concerning heart rate analysis are highlighted, and how the toolkit provides a flexible environment to ameliorate common problems that typically lead to trial rejection is discussed. Source code for this program may be downloaded from the Psychonomic Society Web archive at www.psychonomic.org/archive/.

  11. The influence of physical exertion on basic hematological parameters values and heart rate in trotters

    Directory of Open Access Journals (Sweden)

    Slijepčević Dajana

    2014-01-01

    Full Text Available One of very important prerequisites for achieving good results in races, in addition to genetic predisposition, quality training and good health, are optimal values for number of erythrocytes, concentration of haemoglobin and hematocrit, of which depends efficient oxygen supply of muscles during great efforts. The stated values, along with data on heart rate, are useful indicators of the degree of horse fitness and readiness for horse race. The influence of physical exertion on the values of basic hematological parameters as well as on heart rate, was investigated on 6 trotters, in training at the Belgrade racetrack (one head of Italian trotter, male, 3 years old; 3 heads of American trotter, male, 3,4 and 6 years old and two heads of Serbian trotter, female, 4 and 5 years old. The blood samples for hematological tests were taken by punction of jugular vein in resting phase - immediately before the commencement of work, after light trot warming for 3000 m and fast trot for 1000 m, with 30 minutes rest between the two runnings. The heart rate was monitored continuously by radio telemetry cardiometer, from the moment they were taken from their boxes and harnessing to the completion of work. The obtained results confirm the relationship between the rise of heart rate and hematocrit values: maximal hematocrit values were determined after the first running (0.49±0.05, in regard to 0.42±0.03 in resting phase, but 30 minutes after the second running there was a slight drop of hematocrit values (0.46±0.04. The blood samples in both cases were taken after fast trot during which there were recorded maximal pulse values, so in the moment of sampling the pulse lowered close to the values in resting - after the first running from 192.23±19.66, and after the second from 180.33±17.22 to 40.67±5.76.

  12. Extracting fetal heart beats from maternal abdominal recordings: selection of the optimal principal components

    International Nuclear Information System (INIS)

    Di Maria, Costanzo; Liu, Chengyu; Zheng, Dingchang; Murray, Alan; Langley, Philip

    2014-01-01

    This study presents a systematic comparison of different approaches to the automated selection of the principal components (PC) which optimise the detection of maternal and fetal heart beats from non-invasive maternal abdominal recordings. A public database of 75 4-channel non-invasive maternal abdominal recordings was used for training the algorithm. Four methods were developed and assessed to determine the optimal PC: (1) power spectral distribution, (2) root mean square, (3) sample entropy, and (4) QRS template. The sensitivity of the performance of the algorithm to large-amplitude noise removal (by wavelet de-noising) and maternal beat cancellation methods were also assessed. The accuracy of maternal and fetal beat detection was assessed against reference annotations and quantified using the detection accuracy score F1 [2*PPV*Se / (PPV + Se)], sensitivity (Se), and positive predictive value (PPV). The best performing implementation was assessed on a test dataset of 100 recordings and the agreement between the computed and the reference fetal heart rate (fHR) and fetal RR (fRR) time series quantified. The best performance for detecting maternal beats (F1 99.3%, Se 99.0%, PPV 99.7%) was obtained when using the QRS template method to select the optimal maternal PC and applying wavelet de-noising. The best performance for detecting fetal beats (F1 89.8%, Se 89.3%, PPV 90.5%) was obtained when the optimal fetal PC was selected using the sample entropy method and utilising a fixed-length time window for the cancellation of the maternal beats. The performance on the test dataset was 142.7 beats 2 /min 2 for fHR and 19.9 ms for fRR, ranking respectively 14 and 17 (out of 29) when compared to the other algorithms presented at the Physionet Challenge 2013. (paper)

  13. Cardiovascular Reactivity and Heart Rate Variability in Panic Disorder

    National Research Council Canada - National Science Library

    Santiago, Helen T

    1999-01-01

    .... Because previous studies of cardiovascular reactivity and heart rate variability have been inconclusive, these factors were re-examined in panickers and controls during physiological challenge...

  14. The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure

    International Nuclear Information System (INIS)

    Turianikova, Zuzana; Javorka, Kamil; Calkovska, Andrea; Javorka, Michal; Baumert, Mathias

    2011-01-01

    Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1–10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change

  15. Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years - United States, 1968-2015.

    Science.gov (United States)

    Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele

    2018-03-30

    Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. 1968-2015. The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968-2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968-2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases occurring during the 1970s and 1980s followed by small but steady

  16. Effect of Heart rate on Basketball Three-Point Shot Accuracy

    OpenAIRE

    Luca P. Ardigò; Goran Kuvacic; Antonio D. Iacono; Giacomo Dascanio; Johnny Padulo; Johnny Padulo

    2018-01-01

    The three-point shot (3S) is a fundamental basketball skill used frequently during a game, and is often a main determinant of the final result. The aim of the study was to investigate the effect of different metabolic conditions, in terms of heart rates, on 3S accuracy (3S%) in 24 male (Under 17) basketball players (age 16.3 ± 0.6 yrs). 3S performance was specifically investigated at different heart rates. All sessions consisted of 10 consecutive 3Ss from five different significant field spot...

  17. Heart rate-based lactate minimum test: a reproducible method.

    NARCIS (Netherlands)

    Strupler, M.; Muller, G.; Perret, C.

    2009-01-01

    OBJECTIVE: To find the individual intensity for aerobic endurance training, the lactate minimum test (LMT) seems to be a promising method. LMTs described in the literature consist of speed or work rate-based protocols, but for training prescription in daily practice mostly heart rate is used. The

  18. Effect of atrioventricular conduction on heart rate variability

    KAUST Repository

    Ahmad, Talha Jamal; Ali, Hussnain; Majeed, S. M Imran; Khan, Shoab A.

    2011-01-01

    This paper discusses the effect of atrioventricular conduction time (AVCT) on the short-term Heart Rate Variability (HRV) by computing HRV parameters using intervals between the onsets of successive P waves (PP time series) for three groups: normal

  19. gHRV: Heart rate variability analysis made easy.

    Science.gov (United States)

    Rodríguez-Liñares, L; Lado, M J; Vila, X A; Méndez, A J; Cuesta, P

    2014-08-01

    In this paper, the gHRV software tool is presented. It is a simple, free and portable tool developed in python for analysing heart rate variability. It includes a graphical user interface and it can import files in multiple formats, analyse time intervals in the signal, test statistical significance and export the results. This paper also contains, as an example of use, a clinical analysis performed with the gHRV tool, namely to determine whether the heart rate variability indexes change across different stages of sleep. Results from tests completed by researchers who have tried gHRV are also explained: in general the application was positively valued and results reflect a high level of satisfaction. gHRV is in continuous development and new versions will include suggestions made by testers. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Using a smartphone to measure heart rate changes during relived happiness and anger

    NARCIS (Netherlands)

    Lakens, D.

    2013-01-01

    This study demonstrates the feasibility of measuring heart rate differences associated with emotional states such as anger and happiness with a smartphone. Novice experimenters measured higher heart rates during relived anger and happiness (replicating findings in the literature) outside a

  1. Automatic heart rate normalization for accurate energy expenditure normalization : an analysis of activities of daily living and heart rate features

    NARCIS (Netherlands)

    Altini, M.; Penders, J.; Vullers, R.J.M.; Amft, O.D.

    2014-01-01

    Introduction: This article is part of the Focus Theme of Methods of Information in Medicine on "Pervasive Intelligent Technologies for Health". Background: Energy Expenditure (EE) estimation algorithms using Heart Rate (HR) or a combination of accelerometer and HR data suffer from large error due to

  2. Heart rate variability in normal-weight patients with polycystic ovary syndrome

    OpenAIRE

    Kilit, Celal; Kilit, T?rkan Pa?al?

    2017-01-01

    Objective: Polycystic ovary syndrome (PCOS) is an endocrine disease closely related to several risk factors of cardiovascular disease. Obese women with PCOS show altered autonomic modulation. The results of studies investigating cardiac autonomic functions of normal-weight women with PCOS are conflicting. The aim of the study was to assess the reactivity of cardiac sympathovagal balance in normal-weight women with PCOS by heart rate variability analysis. Methods: We examined the heart rate va...

  3. Early warnings of heart rate deterioration

    OpenAIRE

    Almeida, Vânia G.; Nabney, Ian T.

    2016-01-01

    Hospitals can experience difficulty in detecting and responding to early signs of patient deterioration leading to late intensive care referrals, excess mortality and morbidity, and increased hospital costs. Our study aims to explore potential indicators of physiological deterioration by the analysis of vital-signs. The dataset used comprises heart rate (HR) measurements from MIMIC II waveform database, taken from six patients admitted to the Intensive Care Unit (ICU) and diagnosed with sever...

  4. How Live Performance Moves the Human Heart.

    Directory of Open Access Journals (Sweden)

    Haruka Shoda

    Full Text Available We investigated how the audience member's physiological reactions differ as a function of listening context (i.e., live versus recorded music contexts. Thirty-seven audience members were assigned to one of seven pianists' performances and listened to his/her live performances of six pieces (fast and slow pieces by Bach, Schumann, and Debussy. Approximately 10 weeks after the live performance, each of the audience members returned to the same room and listened to the recorded performances of the same pianists' via speakers. We recorded the audience members' electrocardiograms in listening to the performances in both conditions, and analyzed their heart rates and the spectral features of the heart-rate variability (i.e., HF/TF, LF/HF. Results showed that the audience's heart rate was higher for the faster than the slower piece only in the live condition. As compared with the recorded condition, the audience's sympathovagal balance (LF/HF was less while their vagal nervous system (HF/TF was activated more in the live condition, which appears to suggest that sharing the ongoing musical moments with the pianist reduces the audience's physiological stress. The results are discussed in terms of the audience's superior attention and temporal entrainment to live performance.

  5. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    Background: Previous studies of autonomic nervous system activity through analysis of heart rate variability (HRV) have demonstrated increased sympathetic activity during positive-pressure pneumoperitoneum. We employed an online, continuous method for rapid HRV analysis (MemCalc™, Tarawa, Suwa Trust, Tokyo, ...

  6. Endogenous Pain Modulation: Association with Resting Heart Rate Variability and Negative Affectivity.

    Science.gov (United States)

    Van Den Houte, Maaike; Van Oudenhove, Lukas; Bogaerts, Katleen; Van Diest, Ilse; Van den Bergh, Omer

    2017-07-21

    Several chronic pain syndromes are characterized by deficient endogenous pain modulation as well as elevated negative affectivity and reduced resting heart rate variability. In order to elucidate the relationships between these characteristics, we investigated whether negative affectivity and heart rate variability are associated with endogenous pain modulation in a healthy population. An offset analgesia paradigm with noxious thermal stimulation calibrated to the individual's pain threshold was used to measure endogenous pain modulation magnitude in 63 healthy individuals. Pain ratings during constant noxious heat stimulation to the arm (15 seconds) were compared with ratings during noxious stimulation comprising a 1 °C rise and return of temperature to the initial level (offset trials, 15 seconds). Offset analgesia was defined as the reduction in pain following the 1 °C decrease relative to pain at the same time point during continuous heat stimulation. Evidence for an offset analgesia effect could only be found when noxious stimulation intensity (and, hence, the individual's pain threshold) was intermediate (46 °C or 47 °C). Offset analgesia magnitude was also moderated by resting heart rate variability: a small but significant offset effect was found in participants with high but not low heart rate variability. Negative affectivity was not related to offset analgesia magnitude. These results indicate that resting heart rate variability (HRV) is related to endogenous pain modulation (EPM) in a healthy population. Future research should focus on clarifying the causal relationship between HRV and EPM and chronic pain by using longitudinal study designs. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. Incident solar radiation and coronary heart disease mortality rates in Europe

    International Nuclear Information System (INIS)

    Wong, Alfred

    2008-01-01

    The reported low mortality rate from coronary heart disease in Portugal, Spain, Italy, Greece, and France, to a lesser extent, has been attributed in numerous nutritional studies to the consumption of a Mediterranean-type diet. There are still many unresolved issues about the direct causal effect of the Mediterranean dietary regime on low incidence of coronary heart disease. An analysis of coronary heart disease mortality rates in Europe from a latitudinal gradient perspective has shown to have a close correlation to incident solar radiation. It is surmised that the resulting increased in situ biosynthesis of Vitamin D 3 could be the critical missing confounder in the analysis of the beneficial health outcome of the Mediterranean diet

  8. Effect of pre operative heart rate on post spinal hypotension in obsteric patients

    International Nuclear Information System (INIS)

    Khan, S.; Zahoor, M.U.; Zaid, A.Y.; Buland, K.

    2010-01-01

    The purpose of the study was to determine the association between of preoperative heart rate and post spinal hypotension in women undergoing cesarean section, Two hundred patients undergoing caesarean were included in the study selected on non probability convenience sampling technique, The patients were divided into two groups depending upon their pre operative heart rate. Spinal anesthesia was administered and number of patients developing hypotension was noted. Among 200 patients, who were included in the study; 112 were placed in group A and 88 were placed in group B depending on mean heart rate of 90 beats per minute or less or 91 beats per minute or more respectively. In group A 14 (11.86%) patients developed hypotension where as in group B 28 (31,82%) patients developed hypotension. Pre operative heart rate is significantly associated with post spinal hypotension in obstetric patients undergoing cesarean section. (author)

  9. Design of a heart rate controller for treadmill exercise using a recurrent fuzzy neural network.

    Science.gov (United States)

    Lu, Chun-Hao; Wang, Wei-Cheng; Tai, Cheng-Chi; Chen, Tien-Chi

    2016-05-01

    In this study, we developed a computer controlled treadmill system using a recurrent fuzzy neural network heart rate controller (RFNNHRC). Treadmill speeds and inclines were controlled by corresponding control servo motors. The RFNNHRC was used to generate the control signals to automatically control treadmill speed and incline to minimize the user heart rate deviations from a preset profile. The RFNNHRC combines a fuzzy reasoning capability to accommodate uncertain information and an artificial recurrent neural network learning process that corrects for treadmill system nonlinearities and uncertainties. Treadmill speeds and inclines are controlled by the RFNNHRC to achieve minimal heart rate deviation from a pre-set profile using adjustable parameters and an on-line learning algorithm that provides robust performance against parameter variations. The on-line learning algorithm of RFNNHRC was developed and implemented using a dsPIC 30F4011 DSP. Application of the proposed control scheme to heart rate responses of runners resulted in smaller fluctuations than those produced by using proportional integra control, and treadmill speeds and inclines were smoother. The present experiments demonstrate improved heart rate tracking performance with the proposed control scheme. The RFNNHRC scheme with adjustable parameters and an on-line learning algorithm was applied to a computer controlled treadmill system with heart rate control during treadmill exercise. Novel RFNNHRC structure and controller stability analyses were introduced. The RFNNHRC were tuned using a Lyapunov function to ensure system stability. The superior heart rate control with the proposed RFNNHRC scheme was demonstrated with various pre-set heart rates. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Relationship between Autonomic Markers of Heart Rate and Subjective Indicators of Recovery Status in Male, Elite Badminton Players

    Directory of Open Access Journals (Sweden)

    Christo A. Bisschoff, Ben Coetzee, Michael R. Esco

    2016-12-01

    Full Text Available The primary aim of the study was to determine if heart rate variability (HRV, and heart rate recovery (HRR are related to several subjective indicators of recovery status (muscle soreness, hydration status, sleep quality and quantity as well as pre-competition mood states for different match periods in male, elite, African, singles badminton players. HRV and HRR were measured in twenty-two badminton players before (pre-match, during (in-match, after (post-match and during rest periods (in-match rest of 46 national and international matches. Muscle soreness, hydration status, and sleep quality and quantity were measured on a daily basis whereas mood states were measured just before each match via questionnaires. Prior to each match warm-up, players were fitted with a Fix Polar Heart Rate Transmitter Belt to record heart rate every second during each match and HRR during service breaks and after matches. Kubios HRV software was used for final HRV analyses from the series of R-R-intervals. A strong, significant canonical correlation (Rc = 0.96, p = 0.014 was found between HRV, HRR and subjective indicators of recovery status for the in-match period, but only strong, non-significant relationships were observed for pre-match (Rc = 0.98, p = 0.626 and post-match periods (Rc = 0.98, p = 0.085 and a low non-significant relationship (Rc = 0.69, p = 0.258 for the in-match rest period. Canonical functions accounted for between 47.89% and 96.43% of the total variation between the two canonical variants. Results further revealed that Ln-HFnu, the energy index and vigour were the most prominent variables in the relationship between the autonomic markers of heart rate and recovery-related variables. In conclusion, this study proved that subjective indicators of recovery status influence HRV and HRR measures obtained in a competitive badminton environment and should therefore be incorporated in protocols that evaluate these ANS-related parameters.

  11. Relationship between Autonomic Markers of Heart Rate and Subjective Indicators of Recovery Status in Male, Elite Badminton Players.

    Science.gov (United States)

    Bisschoff, Christo A; Coetzee, Ben; Esco, Michael R

    2016-12-01

    The primary aim of the study was to determine if heart rate variability (HRV), and heart rate recovery (HRR) are related to several subjective indicators of recovery status (muscle soreness, hydration status, sleep quality and quantity as well as pre-competition mood states) for different match periods in male, elite, African, singles badminton players. HRV and HRR were measured in twenty-two badminton players before (pre-match), during (in-match), after (post-match) and during rest periods (in-match rest) of 46 national and international matches. Muscle soreness, hydration status, and sleep quality and quantity were measured on a daily basis whereas mood states were measured just before each match via questionnaires. Prior to each match warm-up, players were fitted with a Fix Polar Heart Rate Transmitter Belt to record heart rate every second during each match and HRR during service breaks and after matches. Kubios HRV software was used for final HRV analyses from the series of R-R-intervals. A strong, significant canonical correlation (Rc = 0.96, p = 0.014) was found between HRV, HRR and subjective indicators of recovery status for the in-match period, but only strong, non-significant relationships were observed for pre-match (Rc = 0.98, p = 0.626) and post-match periods (Rc = 0.98, p = 0.085) and a low non-significant relationship (Rc = 0.69, p = 0.258) for the in-match rest period. Canonical functions accounted for between 47.89% and 96.43% of the total variation between the two canonical variants. Results further revealed that Ln-HFnu, the energy index and vigour were the most prominent variables in the relationship between the autonomic markers of heart rate and recovery-related variables. In conclusion, this study proved that subjective indicators of recovery status influence HRV and HRR measures obtained in a competitive badminton environment and should therefore be incorporated in protocols that evaluate these ANS-related parameters.

  12. Major depressive disorder with melancholia displays robust alterations in resting state heart rate and its variability: Implications for future morbidity and mortality

    Directory of Open Access Journals (Sweden)

    Andrew eKemp

    2014-11-01

    Full Text Available Background: Major depressive disorder (MDD is associated with increased heart rate and reductions in its variability (HRV – markers of future morbidity and mortality – yet prior studies have reported contradictory effects. We hypothesised that increases in heart rate and reductions in HRV would be more robust in melancholia relative to controls, than in patients with non-melancholia. Methods: A total of 72 patients with a primary diagnosis of MDD (age M: 36.26, SE: 1.34; 42 females and 94 controls (age M: 35.69, SE: 1.16; 52 females were included in this study. Heart rate and measures of its variability (HRV were calculated from two 2-minute electrocardiogram recordings during resting state. Propensity score matching controlled imbalance on potential confounds between patients with melancholia (n=40 and non-melancholia (n=32 including age, gender, disorder severity and comorbid anxiety disorders. Results: MDD patients with melancholia displayed significantly increased heart rate and lower resting-state HRV (including the square root of the mean squared differences between successive N–N intervals, the absolute power of high frequency and standard deviation of the Poincaré plot perpendicular to the line of identity measures of HRV relative to controls, findings associated with a moderate effect size (Cohens d’s = 0.56-0.58. Patients with melancholia also displayed an increased heart rate relative to those with non-melancholia (Cohen’s d = 0.20.Conclusion: MDD patients with melancholia – but not non-melancholia – display robust increases in heart rate and decreases in HRV. These findings may underpin a variety of behavioural impairments in patients with melancholia including somatic symptoms, cognitive impairment, reduced responsiveness to the environment, and over the longer-term, morbidity and mortality.

  13. Heart rate biofeedback fails to enhance children's ability to identify time spent in moderate to vigorous physical activity.

    Science.gov (United States)

    Conley, Marguerite M; Gastin, Paul B; Brown, Helen; Shaw, Christine

    2011-03-01

    Physical activity recommendations for children in several countries advise that all young people should accumulate at least 60 min of moderate to vigorous physical activity every day. Perceiving physical activity intensity, however, can be a difficult task for children and it is not clear whether children can identify their levels of moderate to vigorous physical activity in accordance with the recommended guidelines. This study aimed to (1) explore whether children can identify time spent in moderate to vigorous physical activity; and (2) investigate whether heart rate biofeedback would improve children's ability to estimate time spent in moderate to vigorous physical activity. Thirty seven children (15 boys and 22 girls, mean age 12.6 years) wore data recording Polar E600 heart rate monitors during eight physical education lessons. At the end of each lesson children's estimated time in zone was compared to their actual time in zone. During a six lesson Intervention phase, one class was assigned to a biofeedback group whilst the other class acted as the control group and received no heart rate biofeedback. Post-Intervention, students in the biofeedback group were no better than the control group at estimating time spent in zone (mean relative error of estimation biofeedback group: Pre-Intervention 41±32% to Post-Intervention 28±26%; control group: Pre-Intervention 40±39% to Post-Intervention 31±37%). Thus it seems that identifying time spent in moderate to vigorous physical activity remains a complex task for children aged 11-13 even with the help of heart rate biofeedback. Copyright © 2010 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  14. Ivabradine Improves Heart Rate Variability in Patients with Nonischemic Dilated Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Ertugrul Kurtoglu

    2014-10-01

    Full Text Available Background: Ivabradine is a novel specific heart rate (HR-lowering agent that improves event-free survival in patients with heart failure (HF. Objectives: We aimed to evaluate the effect of ivabradine on time domain indices of heart rate variability (HRV in patients with HF. Methods: Forty-eight patients with compensated HF of nonischemic origin were included. Ivabradine treatment was initiated according to the latest HF guidelines. For HRV analysis, 24-h Holter recording was obtained from each patient before and after 8 weeks of treatment with ivabradine. Results: The mean RR interval, standard deviation of all normal to normal RR intervals (SDNN, the standard deviation of 5-min mean RR intervals (SDANN, the mean of the standard deviation of all normal-to-normal RR intervals for all 5-min segments (SDNN index, the percentage of successive normal RR intervals exceeding 50 ms (pNN50, and the square root of the mean of the squares of the differences between successive normal to normal RR intervals (RMSSD were low at baseline before treatment with ivabradine. After 8 weeks of treatment with ivabradine, the mean HR (83.6 ± 8.0 and 64.6 ± 5.8, p < 0.0001, mean RR interval (713 ± 74 and 943 ± 101 ms, p < 0.0001, SDNN (56.2 ± 15.7 and 87.9 ± 19.4 ms, p < 0.0001, SDANN (49.5 ± 14.7 and 76.4 ± 19.5 ms, p < 0.0001, SDNN index (24.7 ± 8.8 and 38.3 ± 13.1 ms, p < 0.0001, pNN50 (2.4 ± 1.6 and 3.2 ± 2.2 %, p < 0.0001, and RMSSD (13.5 ± 4.6 and 17.8 ± 5.4 ms, p < 0.0001 substantially improved, which sustained during both when awake and while asleep. Conclusion: Our findings suggest that treatment with ivabradine improves HRV in nonischemic patients with HF.

  15. Changes in heart rate associated with contest outcome in agonistic encounters in lobsters.

    Science.gov (United States)

    Hernáindez-Falcón, Jesús; Basu, Alo C; Govindasamy, Siddhartan; Kravitz, Edward A

    2005-03-01

    Agonistic contests between lobsters housed together in a confined space progress through encounters of increasing intensity until a dominance relationship is established. Once this relationship is established, losing animals continually retreat from the advances of winners. These encounters are likely to consume much energy in both winning and losing animals. Therefore, one might expect involvement of many physiological systems before, during and after fights. Here, we report effects of agonistic encounters on cardiac frequency in winning and losing adult lobsters involved in dyadic interactions. The results show that: (i) small but significant increases in heart rate are observed upon chemical detection of a conspecific; (ii) during agonistic interactions, further increases in heart rate are seen; and (iii) ultimate winners exhibit greater increases in heart rate lasting longer periods of time compared to ultimate losers. Heart rate in winners remains elevated for at least 15 min after the contests have ended and animals have been returned to their home tanks. Reduced effects are seen in second and third pairings between familiar opponents. The sustained changes in heart rate that we observe in winning lobsters may result from hormonal modulation of cardiac function related to the change in social status brought about by contest outcome.

  16. Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR.

    Science.gov (United States)

    Bai, Yang; Hibbing, Paul; Mantis, Constantine; Welk, Gregory J

    2018-08-01

    The purpose of this investigation was to examine the validity of energy expenditure (EE), steps, and heart rate measured with the Apple Watch 1 and Fitbit Charge HR. Thirty-nine healthy adults wore the two monitors while completing a semi-structured activity protocol consisting of 20 minutes of sedentary activity, 25 minutes of aerobic exercise, and 25 minutes of light intensity physical activity. Criterion measures were obtained from an Oxycon Mobile for EE, a pedometer for steps, and a Polar heart rate strap worn on the chest for heart rate. For estimating whole-trial EE, the mean absolute percent error (MAPE) from Fitbit Charge HR (32.9%) was more than twice that of Apple Watch 1 (15.2%). This trend was consistent for the individual conditions. Both monitors accurately assessed steps during aerobic activity (MAPE Apple : 6.2%; MAPE Fitbit : 9.4%) but overestimated steps in light physical activity. For heart rate, Fitbit Charge HR produced its smallest MAPE in sedentary behaviors (7.2%), followed by aerobic exercise (8.4%), and light activity (10.1%). The Apple Watch 1 had stronger validity than the Fitbit Charge HR for assessing overall EE and steps during aerobic exercise. The Fitbit Charge HR provided heart rate estimates that were statistically equivalent to Polar monitor.

  17. Embryos in the fast lane: high-temperature heart rates of turtles decline after hatching.

    Directory of Open Access Journals (Sweden)

    Wei-Guo Du

    Full Text Available In ectotherms such as turtles, the relationship between cardiovascular function and temperature may be subject to different selective pressures in different life-history stages. Because embryos benefit by developing as rapidly as possible, and can "afford" to expend energy to do so (because they have access to the yolk for nutrition, they benefit from rapid heart (and thus, developmental rates. In contrast, hatchlings do not have a guaranteed food supply, and maximal growth rates may not enhance fitness--and so, we might expect a lower heart rate, especially at high temperatures where metabolic costs are greatest. Our data on two species of emydid turtles, Chrysemys picta, and Graptemys pseudogeographica kohnii, support these predictions. Heart rates of embryos and hatchlings were similar at low temperatures, but heart rates at higher temperatures were much greater before than after hatching.

  18. Continuous measurement of heart rate variability following carbon ...

    African Journals Online (AJOL)

    2010-07-16

    Jul 16, 2010 ... Power spectral analysis of the electrocardiographic R-R interval [heart rate variability: (HRV)] is a well known, non- invasive method for assessing autonomic nervous activity.1. Studies using HRV analysis during positive-pressure pneumoperitoneum (PPP) have demonstrated increased sympathetic ...

  19. Universal design of a microcontroller and IoT system to detect the heart rate

    Science.gov (United States)

    Uwamahoro, Raphael; Mushikiwabeza, Alexie; Minani, Gerard; Mohan Murari, Bhaskar

    2017-11-01

    Heart rate analysis provides vital information of the present condition of the human body. It helps medical professionals in diagnosis of various malfunctions of the body. The limitation of vision impaired and blind people to access medical devices cause a considerable loss of life. In this paper, we intended to develop a heart rate detection system that is usable for people with normal and abnormal vision. The system is based on a non-invasive method of measuring the variation of the tissue blood flow rate by means of a photo transmitter and detector through fingertip known as photoplethysmography (PPG). The signal detected is firstly passed through active low pass filter and then amplified by a two stages high gain amplifier. The amplified signal is feed into the microcontroller to calculate the heart rate and displays the heart beat via sound systems and Liquid Crystal Display (LCD). To distinguish arrhythmia, normal heart rate and abnormal working conditions of the system, recognition is provided in different sounds, LCD readings and Light Emitting Diodes (LED).

  20. Lack of evidence for low-dimensional chaos in heart rate variability

    DEFF Research Database (Denmark)

    Kanters, J K; Holstein-Rathlou, N H; Agner, E

    1994-01-01

    INTRODUCTION: The term chaos is used to describe erratic or apparently random time-dependent behavior in deterministic systems. It has been suggested that the variability observed in the normal heart rate may be due to chaos, but this question has not been settled. METHODS AND RESULTS: Heart rate...... in the experimental data, but the prediction error as a function of the prediction length increased at a slower rate than characteristic of a low-dimensional chaotic system. CONCLUSION: There is no evidence for low-dimensional chaos in the time series of RR intervals from healthy human subjects. However, nonlinear...

  1. Visualization of heart rate variability of long-term heart transplant patient by transition networks: a case report

    Directory of Open Access Journals (Sweden)

    Joanna eWdowczyk

    2016-03-01

    Full Text Available We present a heart transplant patient at his 17th year of uncomplicated follow-up. Within a frame of routine check out several tests were performed. With such a long and uneventful follow-up some degree of graft reinnervation could be anticipated. However, the patient's electrocardiogram and exercise parameters seemed largely inconclusive in this regard. The exercise heart rate dynamics were suggestive of only mild, if any parasympathetic reinnervation of the graft with persisting sympathetic activation. On the other hand, traditional heart rate variability (HRV indices were inadequately high, due to erratic rhythm resulting from interference of the persisting recipient sinus node or nonconducted atrial parasystole. New tools, originated from network representation of time series, by visualization short-term dynamical patterns, provided a method to discern HRV increase due to reinnervation from other reasons.

  2. Heart Rate Variability Monitoring during Sleep Based on Capacitively Coupled Textile Electrodes on a Bed

    Directory of Open Access Journals (Sweden)

    Hong Ji Lee

    2015-05-01

    Full Text Available In this study, we developed and tested a capacitively coupled electrocardiogram (ECG measurement system using conductive textiles on a bed, for long-term healthcare monitoring. The system, which was designed to measure ECG in a bed with no constraints of sleep position and posture, included a foam layer to increase the contact region with the curvature of the body and a cover to ensure durability and easy installation. Nine healthy subjects participated in the experiment during polysomnography (PSG, and the heart rate (HR coverage and heart rate variability (HRV parameters were analyzed to evaluate the system. The experimental results showed that the mean of R-peak coverage was 98.0% (95.5%–99.7%, and the normalized errors of HRV time and spectral measures between the Ag/AgCl system and our system ranged from 0.15% to 4.20%. The root mean square errors for inter-beat (RR intervals and HR were 1.36 ms and 0.09 bpm, respectively. We also showed the potential of our developed system for rapid eye movement (REM sleep and wake detection as well as for recording of abnormal states.

  3. Analyses of Heart Rate, Respiration and Cardiorespiratory Coupling in Patients with Schizophrenia

    Directory of Open Access Journals (Sweden)

    Steffen Schulz

    2015-01-01

    Full Text Available Schizophrenia is a severe mental disorder associated with a significantly increased cardiovascular mortality rate. However, the underlying mechanisms leading to this cardiovascular disease (CVD are not fully known. Therefore, the objective of this study was to characterize the cardiorespiratory influence by investigating heart rate, respiration and the causal strength and direction of cardiorespiratory coupling (CRC, based mainly on entropy measures. We investigated 23 non-medicated patients with schizophrenia (SZ, comparing them to 23 age- and gender-matched healthy controls (CO. A significantly reduced complexity was found for the heart rate and a significantly increased complexity in respiration and CRC in SZ patients when compared to corresponding measurements from CO (p < 0.001. CRC analyses revealed a clear coupling, with a driver-responder relationship from respiration to heart rate in SZ patients. Moreover, a slight driver-responder relationship from heart rate to respiration could be recognized. These findings lead to the assumption that SZ should be considered to be a high-risk group for CVD. We hypothesize that the varying cardiorespiratory regulation contributes to the increased risk for cardiac mortality. Therefore, regular monitoring of the cardiorespiratory status of SZ is suggested to identify autonomic regulation impairment at an early stage—to develop timely and effective treatment and intervention strategies.

  4. Nonlinear analysis of heart rate variability in patients with eating disorders

    NARCIS (Netherlands)

    Vigo, Daniel E.; Castro, Mariana N.; Dorpinghaus, Andrea; Weidema, Hylke; Cardinali, Daniel P.; Siri, Leonardo Nicola; Rovira, Bernardo; Fahrer, Rodolfo D.; Nogues, Martin; Leiguarda, Ramon C.; Guinjoan, Salvador M.

    2008-01-01

    Patients with anorexia nervosa or bulimia nervosa often have signs of autonomic dysfunction potentially deleterious to the heart. The aim of this study was to ascertain the nonlinear properties of heart rate variability in patients with eating disorders. A group of 33 women with eating disorders (14

  5. Glutamate transporter type 3 knockout leads to decreased heart rate possibly via parasympathetic mechanism

    OpenAIRE

    Deng, Jiao; Li, Jiejie; Li, Liaoliao; Feng, Chenzhuo; Xiong, Lize; Zuo, Zhiyi

    2013-01-01

    Parasympathetic tone is a dominant neural regulator for basal heart rate. Glutamate transporters (EAAT) via their glutamate uptake functions regulate glutamate neurotransmission in the central nervous system. We showed that EAAT type 3 (EAAT3) knockout mice had a slower heart rate than wild-type mice when they were anesthetized. We design this study to determine whether non-anesthetized EAAT3 knockout mice have a slower heart rate and, if so, what may be the mechanism for this effect. Young a...

  6. HEART RATE, MOOD STATES, AND RATING OF PERCEIVED EXERTION AMONG ELDERLY SUBJECTS DURING 3.5 HOURS OF RECREATIONAL ALPINE SKIING

    Directory of Open Access Journals (Sweden)

    Sabine Krautgasser

    2012-12-01

    Full Text Available A decline in physiological functioning and mental wellbeing is common with advancing age. However, these changes may vary among elderly individuals. Physical activity and the response of the elderly to exercise during recreational activities, i.e., recreational alpine skiing, may serve as a catalyst for the improvement of wellbeing and general health. Purpose: The aim of the study was to assess the heart rate (HR response modulations in a group of elderly recreational alpine skiers during 3.5h of skiing. In addition, each group's perceived responses of mood state (MS and rating of perceived exertion (RPE were collected to determine possible contributions to changes in wellbeing as a result of recreational skiing. Methods: Forty-nine healthy elderly participants (mean age: 63±6 yrs, weight: 75.4+13.1 kg, height: 170.5+9.1 cm, BMI: 26+3.2 with at least basic alpine skiing ability participated in a 3.5h ski test. GPS data (GPS Garmin Forerunner 301 were used to monitor altitude and HR and were recorded continuously during the 3.5h of skiing. During skiing, participants were asked at three different times to report RPE and MS. Results: The time spent on the lift during the 3.5h skiing ranged from 21-58% followed by recovery breaks of 17-53% and time spent in downhill skiing ranged from 12-40%. Participants completed 9-23 downhill runs in 3.5h. Average intensities during 3.5 h downhill runs for over 80% of the group were between 50-80% of maximal heart rate (HRmax (220-age. Peak heart rate (HRpeak values during downhill runs for 35% of the group were between 60-70% of HRmax. Statistical analysis revealed numerous significant differences between RPE and MS values for the three different sampling times. The MS in general remained positive and even increased in the categories of happiness and sociability despite an increase in fatigue. Conclusion: The results of this study suggest that the duration and intensity of skiing was appropriate and yielded

  7. Heart Rate Changes in Electroacupuncture Treated Polycystic Ovary in Rats.

    Science.gov (United States)

    Ramadoss, Mukilan; Ramanathan, Gunasekaran; Subbiah, Angelie Jessica; Natrajan, Chidambaranathan

    2016-03-01

    Polycystic Ovary Syndrome (PCOS) is a common metabolic disorder, it affects both humans and animals. It may induce coronary heart disease, obesity and hyperandrogenism. Previous studies show that Low frequency Electroacupuncture (EA) have an effect on PCOS, however the exact pathway is unclear. To find the effect of EA on autonomic activity of the heart in Estradiol Valerate (EV) induced PCOS rats. Heart rate variability (HRV) was assessed in 3 groups: 1) Control; 2) PCOS rats; and 3) PCOS rats after EA treatment (n=8 in each group). From the time domain analysis and frequency domain analysis (linear measures) HRV analysis was done. EA stimulation was given at low frequency of 2Hz for 15 min on alternate days for 4-5 weeks. Collected data were statistically analysed using One-Way Analysis of Variance with the application of multiple comparisons of Tukey test. EA treatment group shows significant reduction in Heart Rate (HR) and low frequency, high frequency ratio (LF/HF); and increase in RR interval, Total Power (TP) when compared to PCOS group. The study concludes that EA treatment has a significant effect on reducing sympathetic tone and decreasing HR in PCOS.

  8. Heart Rate, Stress, and Occupational Noise Exposure among Electronic Waste Recycling Workers

    Directory of Open Access Journals (Sweden)

    Katrina N. Burns

    2016-01-01

    Full Text Available Electronic waste (e-waste is a growing occupational and environmental health issue around the globe. E-waste recycling is a green industry of emerging importance, especially in low-and middle-income countries where much of this recycling work is performed, and where many people’s livelihoods depend on this work. The occupational health hazards of e-waste recycling have not been adequately explored. We performed a cross-sectional study of noise exposures, heart rate, and perceived stress among e-waste recycling workers at a large e-waste site in Accra, Ghana. We interviewed 57 workers and continuously monitored their individual noise exposures and heart rates for up to 24 h. More than 40% of workers had noise exposures that exceeded recommended occupational (85 dBA and community (70 dBA noise exposure limits, and self-reported hearing difficulties were common. Workers also had moderate to high levels of perceived stress as measured via Cohen’s Perceived Stress Scale, and reported a variety of symptoms that could indicate cardiovascular disease. Noise exposures were moderately and significantly correlated with heart rate (Spearman’s ρ 0.46, p < 0.001. A mixed effects linear regression model indicated that a 1 dB increase in noise exposure was associated with a 0.17 increase in heart rate (p-value = 0.01 even after controlling for work activities, age, smoking, perceived stress, and unfavorable physical working conditions. These findings suggest that occupational and non-occupational noise exposure is associated with elevations in average heart rate, which may in turn predict potential cardiovascular damage.

  9. Heart Rate Variability is a Moderating Factor in the Workload-Injury Relationship of Competitive CrossFit™ Athletes

    OpenAIRE

    Williams, Sean; Booton, Thomas; Watson, Matthew; Rowland, Daniel; Altini, Marco

    2017-01-01

    Heart rate variability (HRV) is a popular tool for monitoring training adaptation and readiness in athletes, but it also has the potential to indicate early signs of somatic tissue overload prior to the onset of pain or fully developed injury. Therefore, the aim of this study was to investigate the interaction between HRV, workloads, and risk of overuse problems in competitive CrossFit™ athletes. Daily resting HRV and workloads (duration × session-RPE) were recorded in six competitive CrossFi...

  10. Heart Rate Variability as an Indicator of Chronic Stress Caused by Lameness in Dairy Cows.

    Directory of Open Access Journals (Sweden)

    Levente Kovács

    Full Text Available Most experimental studies on animal stress physiology have focused on acute stress, while chronic stress, which is also encountered in intensive dairy cattle farming--e.g. in case of lameness--, has received little attention. We investigated heart rate (HR and heart rate variability (HRV as indicators of the autonomic nervous system activity and fecal glucocorticoid concentrations as the indicator of the hypothalamic-pituitary-adrenal axis activity in lame (with locomotion scores 4 and 5; n = 51 and non-lame (with locomotion scores 1 and 2; n = 52 Holstein-Friesian cows. Data recorded during the periods of undisturbed lying--representing baseline cardiac activity--were involved in the analysis. Besides linear analysis methods of the cardiac inter-beat interval (time-domain geometric, frequency domain and Poincaré analyses non-linear HRV parameters were also evaluated. With the exception of standard deviation 1 (SD1, all HRV indices were affected by lameness. Heart rate was lower in lame cows than in non-lame ones. Vagal tone parameters were higher in lame cows than in non-lame animals, while indices of the sympathovagal balance reflected on a decreased sympathetic activity in lame cows. All geometric and non-linear HRV measures were lower in lame cows compared to non-lame ones suggesting that chronic stress influenced linear and non-linear characteristics of cardiac function. Lameness had no effect on fecal glucocorticoid concentrations. Our results demonstrate that HRV analysis is a reliable method in the assessment of chronic stress, however, it requires further studies to fully understand the elevated parasympathetic and decreased sympathetic tone in lame animals.

  11. Effect of partial sports massage on blood pressure and heart rate

    Directory of Open Access Journals (Sweden)

    T.D. Pystupa

    2013-12-01

    Full Text Available With the growing popularity and demand for different types of massages (including sports is a growing need for research on specific forms. There is also a need to study the advantages and effects on various body functions. The objective was to study the effect of partial sports massage on blood pressure and heart rate in both men and women. Material and methods. Research has been extended 80 healthy men and women are physically active (age 20-25 years. Blood pressure and heart rate were made on the left arm automatic digital device (model HEM - 907. The device is intended to measure blood pressure. It is established that it is possible to verify the existing beliefs. This promotes more efficient use of massage therapy. Conclusions . Sports massage has an effect on hemodynamic changes, the increase (decrease in blood pressure acceleration (deceleration of the heart rate. It depends on what part of the body exposed to the massage procedure.

  12. GLP-1 receptor stimulation depresses heart rate variability and inhibits neurotransmission to cardiac vagal neurons.

    Science.gov (United States)

    Griffioen, Kathleen J; Wan, Ruiqian; Okun, Eitan; Wang, Xin; Lovett-Barr, Mary Rachael; Li, Yazhou; Mughal, Mohamed R; Mendelowitz, David; Mattson, Mark P

    2011-01-01

    glucagon-like peptide 1 (GLP-1) is an incretin hormone released from the gut in response to food intake. Whereas GLP-1 acts in the periphery to inhibit glucagon secretion and stimulate insulin release, it also acts in the central nervous system to mediate autonomic control of feeding, body temperature, and cardiovascular function. Because of its role as an incretin hormone, GLP-1 receptor analogs are used as a treatment for type 2 diabetes. Central or peripheral administration of GLP-1 increases blood pressure and heart rate, possibly by activating brainstem autonomic nuclei and increasing vagus nerve activity. However, the mechanism(s) by which GLP-1 receptor stimulation affects cardiovascular function are unknown. We used the long-lasting GLP-1 receptor agonist Exendin-4 (Ex-4) to test the hypothesis that GLP-1 signalling modulates central parasympathetic control of heart rate. using a telemetry system, we assessed heart rate in mice during central Ex-4 administration. Heart rate was increased by both acute and chronic central Ex-4 administration. Spectral analysis indicated that the high frequency and low frequency powers of heart rate variability were diminished by Ex-4 treatment. Finally, Ex-4 decreased both excitatory glutamatergic and inhibitory glycinergic neurotransmission to preganglionic parasympathetic cardiac vagal neurons. these data suggest that central GLP-1 receptor stimulation diminishes parasympathetic modulation of the heart thereby increasing heart rate.

  13. Heart rate modulation in stable coronary artery disease without clinical heart failure: What we have already learned from SIGNIFY?

    Directory of Open Access Journals (Sweden)

    Gian Piero Perna

    2016-12-01

    In conclusion, heart rate is a marker of risk but is not a risk factor and/or a target of therapy in patients with stable coronary artery disease and preserved ventricular systolic function. Standard doses of ivabradine are indicated for treatment of angina as an alternative or in addition to beta-blockers, but should not be administered in association with CYP3A4 inhibitors or heart rate-lowering calcium-channel blockers.

  14. High readmission rate after heart valve surgery

    DEFF Research Database (Denmark)

    Sibilitz, K L; Berg, S K; Thygesen, L C

    2015-01-01

    investigated. RESULTS: After valve surgery, the self-reported health was lower (Short Form-36 (SF-36) Physical Component Scale (PCS): 44.5 vs. 50.6 and Mental Component Scale (MCS): 51.9 vs. 55.0, pClinical signs......BACKGROUND: After heart valve surgery, knowledge on long-term self-reported health status and readmission is lacking. Thus, the optimal strategy for out-patient management after surgery remains unclear. METHODS: Using a nationwide survey with linkage to Danish registers with one year follow-up, we...... included all adults 6-12months after heart valve surgery irrespective of valve procedure, during Jan-June 2011 (n=867). Participants completed a questionnaire regarding health-status (n=742), and answers were compared with age- and sex-matched healthy controls. Readmission rates and mortality were...

  15. Heart rate autonomic regulation system at rest and during paced breathing among patients with CRPS as compared to age-matched healthy controls.

    Science.gov (United States)

    Bartur, Gadi; Vatine, Jean-Jacques; Raphaely-Beer, Noa; Peleg, Sara; Katz-Leurer, Michal

    2014-09-01

    The objective of this study is to assess the autonomic nerve heart rate regulation system at rest and its immediate response to paced breathing among patients with complex regional pain syndrome (CRPS) as compared with age-matched healthy controls. Quasiexperimental. Outpatient clinic. Ten patients with CRPS and 10 age- and sex-matched controls. Participants underwent Holter ECG (NorthEast Monitoring, Inc., Maynard, MA, USA) recording during rest and biofeedback-paced breathing session. Heart rate variability (HRV), time, and frequency measures were assessed. HRV and time domain values were significantly lower at rest among patients with CRPS as compared with controls. A significant association was noted between pain rank and HRV frequency measures at rest and during paced breathing; although both groups reduced breathing rate significantly during paced breathing, HRV time domain parameters increased only among the control group. The increased heart rate and decreased HRV at rest in patients with CRPS suggest a general autonomic imbalance. The inability of the patients to increase HRV time domain values during paced breathing may suggest that these patients have sustained stress response with minimal changeability in response to slow-paced breathing stimuli. Wiley Periodicals, Inc.

  16. Simplifying cardiovascular risk estimation using resting heart rate.

    LENUS (Irish Health Repository)

    Cooney, Marie Therese

    2010-09-01

    Elevated resting heart rate (RHR) is a known, independent cardiovascular (CV) risk factor, but is not included in risk estimation systems, including Systematic COronary Risk Evaluation (SCORE). We aimed to derive risk estimation systems including RHR as an extra variable and assess the value of this addition.

  17. A simple test of one minute heart rate variability during deep breathing for evaluation of sympathovagal imbalance in patients with type 2 diabetes mellitus

    International Nuclear Information System (INIS)

    Fareedabanu, A.B.

    2011-01-01

    Heart rate variability (HRV) refers to the magnitude of the fluctuation in the number of heart beats per minute in conjunction with respiration. HRV with deep breathing (HRVdb) has recently become a popular non-invasive research tool in cardiology. This study was carried out to determine and compare the HRV in patients with Type 2 DM with those of Non diabetic controls. Methods: Sixty diabetic patients attending out patient department in Karnataka Institute of Diabetology, Bangalore and 60 age-matched controls were enrolled. HRV was performed on all the subjects and the results obtained were compared between the groups. The One minute HRV was analysed during deep breathing and defined as the difference in beats/minute between the shortest and the longest heart rate interval measured by lead II electrocardiographic recording during six cycles of deep breathing. Results: Statistically significant decrease in mean minimal heart rate and 1 minute HRV (16.30 +- 6.42 vs 29.33 +- 8.39) was observed during deep breathing among Type 2 Diabetic patients on comparison with that of healthy controls. There was no significant difference in mean maximal heart rate between the groups. Conclusion: Significant decrease in HRV in Type 2 DM patients is suggestive of reduced parasympathetic activity or an imbalance between sympathetic and parasympathetic neural activity in them. Hence HRVdb provides a sensitive screening measure for parasympathetic dysfunction in many autonomic disorders. (author)

  18. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals.

    Science.gov (United States)

    Xiong, Jiping; Cai, Lisang; Wang, Fei; He, Xiaowei

    2017-03-03

    Although wrist-type photoplethysmographic (hereafter referred to as WPPG) sensor signals can measure heart rate quite conveniently, the subjects' hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  19. The Use of Heart Rate Monitors in Physical Education

    Science.gov (United States)

    Nichols, Randall; Davis, Kathryn L.; McCord, Tim; Schmidt, Dave; Slezak, Alex M.

    2009-01-01

    The ever-rising rate of obesity and the need for increased physical activity for young children is well documented. Data suggests that today's youth are not participating in enough quality health-enhancing physical activity either in or outside of school. Heart rate monitors have been used by adult exercisers for many years to monitor and assess…

  20. Thermal effect on heart rate and hemodynamics in vitelline arteries of stage 18 chicken embryos.

    Science.gov (United States)

    Lee, Jung Yeop; Lee, Sang Joon

    2010-12-01

    We investigated the thermal effects on heart rate, hemodynamics, and response of vitelline arteries of stage-18 chicken embryos. Heart rate was monitored by a high-speed imaging method, while hemodynamic quantities were evaluated using a particle image velocimetry (PIV) technique. Experiments were carried out at seven different temperatures (36-42 °C with 1 °C interval) after 1h of incubation to stabilize the heart rate. The heart rate increased in a linear manner (r = 0.992). Due to the increased cardiac output (or heart rate), the hemodynamic quantities such as mean velocity (U(mean)), velocity fluctuation (U(fluc)), and peak velocity (U(peak)) also increased with respect to the Womersley number (Ω) in the manner r = 0.599, 0.693, and 0.725, respectively. This indicates that the mechanical force exerting on the vessel walls increases. However, the active response (or regulation) of the vitelline arteries was not observed in this study. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    Science.gov (United States)

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  2. HEART RATE VARIABILITY CLASSIFICATION USING SADE-ELM CLASSIFIER WITH BAT FEATURE SELECTION

    Directory of Open Access Journals (Sweden)

    R Kavitha

    2017-07-01

    Full Text Available The electrical activity of the human heart is measured by the vital bio medical signal called ECG. This electrocardiogram is employed as a crucial source to gather the diagnostic information of a patient’s cardiopathy. The monitoring function of cardiac disease is diagnosed by documenting and handling the electrocardiogram (ECG impulses. In the recent years many research has been done and developing an enhanced method to identify the risk in the patient’s body condition by processing and analysing the ECG signal. This analysis of the signal helps to find the cardiac abnormalities, arrhythmias, and many other heart problems. ECG signal is processed to detect the variability in heart rhythm; heart rate variability is calculated based on the time interval between heart beats. Heart Rate Variability HRV is measured by the variation in the beat to beat interval. The Heart rate Variability (HRV is an essential aspect to diagnose the properties of the heart. Recent development enhances the potential with the aid of non-linear metrics in reference point with feature selection. In this paper, the fundamental elements are taken from the ECG signal for feature selection process where Bat algorithm is employed for feature selection to predict the best feature and presented to the classifier for accurate classification. The popular machine learning algorithm ELM is taken for classification, integrated with evolutionary algorithm named Self- Adaptive Differential Evolution Extreme Learning Machine SADEELM to improve the reliability of classification. It combines Effective Fuzzy Kohonen clustering network (EFKCN to be able to increase the accuracy of the effect for HRV transmission classification. Hence, it is observed that the experiment carried out unveils that the precision is improved by the SADE-ELM method and concurrently optimizes the computation time.

  3. Dogs with macroadenomas have lower body temperature and heart rate than dogs with microadenomas.

    Science.gov (United States)

    Benchekroun, Ghita; Desquilbet, Loic; Herrtage, Michael E; Jeffery, Nick D; Rosenberg, Dan; Granger, Nicolas

    2017-09-01

    Pituitary macroadenomas compress the hypothalamus, which partly regulates heart rate and body temperature. The aim of this study was to investigate whether heart rate and/or body temperature could aid in clinically differentiating dogs with macroadenomas from dogs with microadenomas (i.e. small non-compressive pituitary mass). Two groups of dogs diagnosed with pituitary-dependent hyperadrenocorticism (i.e. Cushing's disease) were included. Heart rate and body temperature were collected on initial presentation before any procedure. Dogs with macroadenoma had a significantly lower heart rate and body temperature (Pdogs with microadenoma. We suggest that the combined cut-off values of 84 beats per minutes and 38.3°C in dogs with Cushing's disease, especially with vague neurological signs (nine of 12 dogs=75%), might help to suspect the presence of a macroadenoma. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. [Effects of Monochord Music on Heart Rate Variability and Self-Reports of Relaxation in Healthy Adults].

    Science.gov (United States)

    Gäbel, Christine; Garrido, Natalia; Koenig, Julian; Hillecke, Thomas Karl; Warth, Marco

    Music-based interventions are considered an effective and low-cost treatment option for stress-related symptoms. The present study aimed to examine the trajectories of the psychophysiological response in apparently healthy participants during a music-based relaxation intervention compared to a verbal relaxation exercise. 70 participants were assigned to either receptive live music (experimental group) or a prerecorded verbal relaxation exercise (control group). Self-ratings of relaxation were assessed before and after each intervention on visual analogue scales and the Relaxation Inventory (RI). The heart rate variability (HRV) was continuously recorded throughout the sessions. Statistical analysis focused on HRV parameters indicative of parasympathetic cardiovascular outflow. We found significant quadratic main effects for time on the mean R-R interval (heart rate), the high-frequency power of HRV (indicative of parasympathetic activity), and the self-ratings of relaxation in both groups. A significant group × time interaction was observed for the cognitive tension subscale of the RI. Participants in both groups showed psychophysiological changes indicative of greater relaxation over the course of the interventions. However, differences between groups were only marginal. Music might be effective in relieving stress and promoting relaxation by altering the autonomic nervous system function. Future studies need to explore the long-term outcomes of such interventions. © 2017 S. Karger GmbH, Freiburg.

  5. Does treadmill running performance, heart rate and breathing rate response during maximal graded exercise improve after volitional respiratory muscle training?

    Science.gov (United States)

    Radhakrishnan, K; Sharma, V K; Subramanian, S K

    2017-05-10

    Maximal physical exertion in sports usually causes fatigue in the exercising muscles, but not in the respiratory muscles due to triggering of the Respiratory muscle metabo-reflex, a sympathetic vasoconstrictor response leading to preferential increment in blood flow to respiratory muscles. 1 We planned to investigate whether a six week yogic pranayama based Volitional Respiratory Muscle Training (VRMT) can improve maximal Graded Exercise Treadmill Test (GXTT) performance in healthy adult recreational sportspersons. Consecutive, consenting healthy adult recreational sportspersons aged 20.56±2.49 years (n=30), volunteered to 'baseline recording' of resting heart rate (HR), blood pressure (BP), respiratory rate (RR), and Bruce ramp protocol maximal GXTT until volitional exhaustion providing total test time (TTT), derived VO2max, Metabolic Equivalent of Task (METs), HR and BP response during maximal GXTT and drop in recovery HR data. After six weeks of observation, they underwent 'pre-intervention recording' followed by supervised VRMT intervention for 6 weeks (30 minutes a day; 5 days a week) and then 'post-intervention recording'. Repeated measures ANOVA with pairwise t statistical comparison was used to analyse the data. After supervised VRMT, we observed significant decrease in their resting supine RR (prespiratory muscle aerobic capacity, attenuation of respiratory muscle metabo-reflex, increase in cardiac stroke volume and autonomic resetting towards parasympatho-dominance. Yogic Pranayama based VRMT can be used in sports conditioning programme of athletes to further improve their maximal exercise performance, and as part of rehabilitation training during return from injury.

  6. Development of an Algorithm for Heart Rate Measurement Using a Mobile Phone Camera

    Directory of Open Access Journals (Sweden)

    D. A. Laure

    2014-01-01

    Full Text Available Nowadays there exist many different ways to measure a person’s heart rate. One of them assumes the usage of a mobile phone built-in camera. This method is easy to use and does not require any additional skills or special devices for heart rate measurement. It requires only a mobile cellphone with a built-in camera and a flash. The main idea of the method is to detect changes in finger skin color that occur due to blood pulsation. The measurement process is simple: the user covers the camera lens with a finger and the application on the mobile phone starts catching and analyzing frames from the camera. Heart rate can be calculated by analyzing average red component values of frames taken by the mobile cellphone camera that contain images of an area of the skin.In this paper the authors review the existing algorithms for heart rate measurement with the help of a mobile phone camera and propose their own algorithm which is more efficient than the reviewed algorithms.

  7. Additive effects of heating and exercise on baroreflex control of heart rate in healthy males.

    Science.gov (United States)

    Peçanha, Tiago; Forjaz, Cláudia L M; Low, David A

    2017-12-01

    This study assessed the additive effects of passive heating and exercise on cardiac baroreflex sensitivity (cBRS) and heart rate variability (HRV). Twelve healthy young men (25 ± 1 yr, 23.8 ± 0.5 kg/m 2 ) randomly underwent two experimental sessions: heat stress (HS; whole body heat stress using a tube-lined suit to increase core temperature by ~1°C) and normothermia (NT). Each session was composed of a preintervention rest (REST1); HS or NT interventions; postintervention rest (REST2); and 14 min of cycling exercise [7 min at 40%HR reserve (EX1) and 7 min at 60%HR reserve (EX2)]. Heart rate and finger blood pressure were continuously recorded. cBRS was assessed using the sequence (cBRS SEQ ) and transfer function (cBRS TF ) methods. HRV was assessed using the indexes standard deviation of RR intervals (SDNN) and root mean square of successive RR intervals (RMSSD). cBRS and HRV were not different between sessions during EX1 and EX2 (i.e., matched heart rate conditions: EX1 = 116 ± 3 vs. 114 ± 3 and EX2 = 143 ± 4 vs. 142 ± 3 beats/min but different workloads: EX1 = 50 ± 9 vs. 114 ± 8 and EX2 = 106 ± 10 vs. 165 ± 8 W; for HS and NT, respectively; P heat stress to exercise does not affect cBRS and HRV. Alternatively, in workload-matched conditions, the addition of heat to exercise results in reduced cBRS and HRV compared with exercise in normothermia. NEW & NOTEWORTHY The present study assessed cardiac baroreflex sensitivity during the combination of heat and exercise stresses. This is the first study to show that prior whole body passive heating reduces cardiac baroreflex sensitivity and autonomic modulation of heart rate during exercise. These findings contribute to the better understanding of the role of thermoregulation on cardiovascular regulation during exercise.

  8. Heart rate, heart rate variability, and arrhythmias in dogs with myxomatous mitral valve disease

    DEFF Research Database (Denmark)

    Rasmussen, Caroline Elisabeth; Falk, Bo Torkel; Zois, Nora Elisabeth

    2012-01-01

    Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD).......Autonomic modulation of heart rhythm is thought to influence the pathophysiology of myxomatous mitral valve disease (MMVD)....

  9. Making the Most of the "Daphnia" Heart Rate Lab: Optimizing the Use of Ethanol, Nicotine & Caffeine

    Science.gov (United States)

    Corotto, Frank; Ceballos, Darrel; Lee, Adam; Vinson, Lindsey

    2010-01-01

    Students commonly test the effects of chemical agents on the heart rate of the crustacean "Daphnia" magna, but the procedure has never been optimized. We determined the effects of three concentrations of ethanol, nicotine, and caffeine and of a control solution on heart rate in "Daphnia." Ethanol at 5% and 10% (v/v) reduced mean heart rate to…

  10. Heart Rate, Stress, and Occupational Noise Exposure among Electronic Waste Recycling Workers.

    Science.gov (United States)

    Burns, Katrina N; Sun, Kan; Fobil, Julius N; Neitzel, Richard L

    2016-01-19

    Electronic waste (e-waste) is a growing occupational and environmental health issue around the globe. E-waste recycling is a green industry of emerging importance, especially in low-and middle-income countries where much of this recycling work is performed, and where many people's livelihoods depend on this work. The occupational health hazards of e-waste recycling have not been adequately explored. We performed a cross-sectional study of noise exposures, heart rate, and perceived stress among e-waste recycling workers at a large e-waste site in Accra, Ghana. We interviewed 57 workers and continuously monitored their individual noise exposures and heart rates for up to 24 h. More than 40% of workers had noise exposures that exceeded recommended occupational (85 dBA) and community (70 dBA) noise exposure limits, and self-reported hearing difficulties were common. Workers also had moderate to high levels of perceived stress as measured via Cohen's Perceived Stress Scale, and reported a variety of symptoms that could indicate cardiovascular disease. Noise exposures were moderately and significantly correlated with heart rate (Spearman's ρ 0.46, p stress, and unfavorable physical working conditions. These findings suggest that occupational and non-occupational noise exposure is associated with elevations in average heart rate, which may in turn predict potential cardiovascular damage.

  11. Attenuated heart rate response in REM sleep behavior disorder and Parkinson's disease

    DEFF Research Database (Denmark)

    Sorensen, Gertrud Laura; Kempfner, Jacob; Zoetmulder, Marielle

    2012-01-01

    The objective of this study was to determine whether patients with Parkinson's disease with and without rapid‐eye‐movement sleep behavior disorder and patients with idiopathic rapid‐eye‐movement sleep behavior disorder have an attenuated heart rate response to arousals or to leg movements during...... sleep compared with healthy controls. Fourteen and 16 Parkinson's patients with and without rapid‐eye‐movement sleep behavior disorder, respectively, 11 idiopathic rapid‐eye‐movement sleep behavior disorder patients, and 17 control subjects underwent 1 night of polysomnography. The heart rate response...... associated with arousal or leg movement from all sleep stages was analyzed from 10 heartbeats before the onset of the sleep event to 15 heartbeats following onset of the sleep event. The heart rate reponse to arousals was significantly lower in both parkinsonian groups compared with the control group...

  12. Heart-Rate Variability—More than Heart Beats?

    Directory of Open Access Journals (Sweden)

    Gernot Ernst

    2017-09-01

    Full Text Available Heart-rate variability (HRV is frequently introduced as mirroring imbalances within the autonomous nerve system. Many investigations are based on the paradigm that increased sympathetic tone is associated with decreased parasympathetic tone and vice versa. But HRV is probably more than an indicator for probable disturbances in the autonomous system. Some perturbations trigger not reciprocal, but parallel changes of vagal and sympathetic nerve activity. HRV has also been considered as a surrogate parameter of the complex interaction between brain and cardiovascular system. Systems biology is an inter-disciplinary field of study focusing on complex interactions within biological systems like the cardiovascular system, with the help of computational models and time series analysis, beyond others. Time series are considered surrogates of the particular system, reflecting robustness or fragility. Increased variability is usually seen as associated with a good health condition, whereas lowered variability might signify pathological changes. This might explain why lower HRV parameters were related to decreased life expectancy in several studies. Newer integrating theories have been proposed. According to them, HRV reflects as much the state of the heart as the state of the brain. The polyvagal theory suggests that the physiological state dictates the range of behavior and psychological experience. Stressful events perpetuate the rhythms of autonomic states, and subsequently, behaviors. Reduced variability will according to this theory not only be a surrogate but represent a fundamental homeostasis mechanism in a pathological state. The neurovisceral integration model proposes that cardiac vagal tone, described in HRV beyond others as HF-index, can mirror the functional balance of the neural networks implicated in emotion–cognition interactions. Both recent models represent a more holistic approach to understanding the significance of HRV.

  13. Heart-Rate Variability-More than Heart Beats?

    Science.gov (United States)

    Ernst, Gernot

    2017-01-01

    Heart-rate variability (HRV) is frequently introduced as mirroring imbalances within the autonomous nerve system. Many investigations are based on the paradigm that increased sympathetic tone is associated with decreased parasympathetic tone and vice versa . But HRV is probably more than an indicator for probable disturbances in the autonomous system. Some perturbations trigger not reciprocal, but parallel changes of vagal and sympathetic nerve activity. HRV has also been considered as a surrogate parameter of the complex interaction between brain and cardiovascular system. Systems biology is an inter-disciplinary field of study focusing on complex interactions within biological systems like the cardiovascular system, with the help of computational models and time series analysis, beyond others. Time series are considered surrogates of the particular system, reflecting robustness or fragility. Increased variability is usually seen as associated with a good health condition, whereas lowered variability might signify pathological changes. This might explain why lower HRV parameters were related to decreased life expectancy in several studies. Newer integrating theories have been proposed. According to them, HRV reflects as much the state of the heart as the state of the brain. The polyvagal theory suggests that the physiological state dictates the range of behavior and psychological experience. Stressful events perpetuate the rhythms of autonomic states, and subsequently, behaviors. Reduced variability will according to this theory not only be a surrogate but represent a fundamental homeostasis mechanism in a pathological state. The neurovisceral integration model proposes that cardiac vagal tone, described in HRV beyond others as HF-index, can mirror the functional balance of the neural networks implicated in emotion-cognition interactions. Both recent models represent a more holistic approach to understanding the significance of HRV.

  14. The effects of short-term relaxation therapy on indices of heart rate variability and blood pressure in young adults.

    Science.gov (United States)

    Pal, Gopal Krushna; Ganesh, Venkata; Karthik, Shanmugavel; Nanda, Nivedita; Pal, Pravati

    2014-01-01

    Assessment of short-term practice of relaxation therapy on autonomic and cardiovascular functions in first-year medical students. Case-control, interventional study. Medical college laboratory. Sixty-seven medical students, divided into two groups: study group (n = 35) and control group (n = 32). Study group subjects practiced relaxation therapy (shavasana with a soothing background music) daily 1 hour for 6 weeks. Control group did not practice relaxation techniques. Cardiovascular parameters and spectral indices of heart rate variability (HRV) were recorded before and after the 6-week practice of relaxation therapy. The data between the groups and the data before and after practice of relaxation techniques were analyzed by one-way analysis of variance and Student t-test. In the study group, prediction of low-frequency to high-frequency ratio (LF-HF) of HRV, the marker of sympathovagal balance, to blood pressure (BP) status was assessed by logistic regression. In the study group, there was significant reduction in heart rate (p = .0001), systolic (p = .0010) and diastolic (p = .0021) pressure, and rate pressure product (p linked to BP status in these individuals.

  15. Study of foetal heart rate patterns in pregnancy with intra-uterine growth restriction during antepartum period

    International Nuclear Information System (INIS)

    Fardiazar, Z.; Abassalizade, F.

    2013-01-01

    Objectives: To evaluate foetal heart rate pattern during antepartum period in pregnancies suffering from intra-uterine growth restriction. Methods: The case control study was conducted at the Alzahra Hospital, Tabriz, Iran from April 2008 to April 2011. It comprised 100 pregnancies with intra-uterine growth restriction and 92 normal pregnancies. The foetal heart rate pattern including basal heart rate, beat-to-beat variation, non-stress test (NST) result and acceleration and deceleration patterns of the heart rate were determined in both groups during the antepartum period. Findings were compared between the two groups and their relation with pregnancy-foetal outcomes was specified in the case group. SPSS 15 was used for statistical analysis. Results: There was no statistically significant difference between the foetus mean basal heart rate in the two groups (p <0.960). Frequency of cases with non-reactive non-stress test in the Cases was significantly higher than Controls (p <0.005). The difference in heart rate acceleration was also not statistically significant (p <0.618). Frequency of cases with low birth weight and caesarian was non-significantly but borderline higher among the Cases (p <0.081 and 0.060, respectively). Conclusion: Abnormal foetal heart rate pattern is more common in pregnancies marked by intra-uterine growth restriction and is directly associated with worse pregnancy/foetal outcomes. (author)

  16. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography

    International Nuclear Information System (INIS)

    Laspas, Fotios; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John; Tsantioti, Dimitra

    2011-01-01

    Background: Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. Purpose: To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Material and Methods: Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Results: Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR =65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Conclusion: Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure

  17. [Design of Oxygen Saturation, Heart Rate, Respiration Rate Detection System Based on Smartphone of Android Operating System].

    Science.gov (United States)

    Zhu, Mingshan; Zeng, Bixin

    2015-03-01

    In this paper, we designed an oxygen saturation, heart rate, respiration rate monitoring system based on smartphone of android operating system, physiological signal acquired by MSP430 microcontroller and transmitted by Bluetooth module.

  18. SVM-Based Spectral Analysis for Heart Rate from Multi-Channel WPPG Sensor Signals

    Directory of Open Access Journals (Sweden)

    Jiping Xiong

    2017-03-01

    Full Text Available Although wrist-type photoplethysmographic (hereafter referred to as WPPG sensor signals can measure heart rate quite conveniently, the subjects’ hand movements can cause strong motion artifacts, and then the motion artifacts will heavily contaminate WPPG signals. Hence, it is challenging for us to accurately estimate heart rate from WPPG signals during intense physical activities. The WWPG method has attracted more attention thanks to the popularity of wrist-worn wearable devices. In this paper, a mixed approach called Mix-SVM is proposed, it can use multi-channel WPPG sensor signals and simultaneous acceleration signals to measurement heart rate. Firstly, we combine the principle component analysis and adaptive filter to remove a part of the motion artifacts. Due to the strong relativity between motion artifacts and acceleration signals, the further denoising problem is regarded as a sparse signals reconstruction problem. Then, we use a spectrum subtraction method to eliminate motion artifacts effectively. Finally, the spectral peak corresponding to heart rate is sought by an SVM-based spectral analysis method. Through the public PPG database in the 2015 IEEE Signal Processing Cup, we acquire the experimental results, i.e., the average absolute error was 1.01 beat per minute, and the Pearson correlation was 0.9972. These results also confirm that the proposed Mix-SVM approach has potential for multi-channel WPPG-based heart rate estimation in the presence of intense physical exercise.

  19. Real-time Continuous Assessment Method for Mental and Physiological Condition using Heart Rate Variability

    Science.gov (United States)

    Yoshida, Yutaka; Yokoyama, Kiyoko; Ishii, Naohiro

    It is necessary to monitor the daily health condition for preventing stress syndrome. In this study, it was proposed the method assessing the mental and physiological condition, such as the work stress or the relaxation, using heart rate variability at real time and continuously. The instantanuous heart rate (HR), and the ratio of the number of extreme points (NEP) and the number of heart beats were calculated for assessing mental and physiological condition. In this method, 20 beats heart rate were used to calculate these indexes. These were calculated in one beat interval. Three conditions, which are sitting rest, performing mental arithmetic and watching relaxation movie, were assessed using our proposed algorithm. The assessment accuracies were 71.9% and 55.8%, when performing mental arithmetic and watching relaxation movie respectively. In this method, the mental and physiological condition was assessed using only 20 regressive heart beats, so this method is considered as the real time assessment method.

  20. ARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.

    Science.gov (United States)

    Kaufmann, Tobias; Sütterlin, Stefan; Schulz, Stefan M; Vögele, Claus

    2011-12-01

    The importance of appropriate handling of artifacts in interbeat interval (IBI) data must not be underestimated. Even a single artifact may cause unreliable heart rate variability (HRV) results. Thus, a robust artifact detection algorithm and the option for manual intervention by the researcher form key components for confident HRV analysis. Here, we present ARTiiFACT, a software tool for processing electrocardiogram and IBI data. Both automated and manual artifact detection and correction are available in a graphical user interface. In addition, ARTiiFACT includes time- and frequency-based HRV analyses and descriptive statistics, thus offering the basic tools for HRV analysis. Notably, all program steps can be executed separately and allow for data export, thus offering high flexibility and interoperability with a whole range of applications.

  1. Heart rate responses induced by acoustic tempo and its interaction with basal heart rate.

    Science.gov (United States)

    Watanabe, Ken; Ooishi, Yuuki; Kashino, Makio

    2017-03-07

    Many studies have revealed the influences of music on the autonomic nervous system (ANS). Since previous studies focused on the effects of acoustic tempo on the ANS, and humans have their own physiological oscillations such as the heart rate (HR), the effects of acoustic tempo might depend on the HR. Here we show the relationship between HR elevation induced by acoustic tempo and individual basal HR. Since high tempo-induced HR elevation requires fast respiration, which is based on sympatho-respiratory coupling, we controlled the participants' respiration at a faster rate (20 CPM) than usual (15 CPM). We found that sound stimuli with a faster tempo than the individual basal HR increased the HR. However, the HR increased following a gradual increase in the acoustic tempo only when the extent of the gradual increase in tempo was within a specific range (around + 2%/min). The HR did not follow the increase in acoustic tempo when the rate of the increase in the acoustic tempo exceeded 3% per minute. These results suggest that the effect of the sympatho-respiratory coupling underlying the HR elevation caused by a high acoustic tempo depends on the basal HR, and the strength and the temporal dynamics of the tempo.

  2. Toward Capturing Momentary Changes of Heart Rate Variability by a Dynamic Analysis Method.

    Directory of Open Access Journals (Sweden)

    Haoshi Zhang

    Full Text Available The analysis of heart rate variability (HRV has been performed on long-term electrocardiography (ECG recordings (12~24 hours and short-term recordings (2~5 minutes, which may not capture momentary change of HRV. In this study, we present a new method to analyze the momentary HRV (mHRV. The ECG recordings were segmented into a series of overlapped HRV analysis windows with a window length of 5 minutes and different time increments. The performance of the proposed method in delineating the dynamics of momentary HRV measurement was evaluated with four commonly used time courses of HRV measures on both synthetic time series and real ECG recordings from human subjects and dogs. Our results showed that a smaller time increment could capture more dynamical information on transient changes. Considering a too short increment such as 10 s would cause the indented time courses of the four measures, a 1-min time increment (4-min overlapping was suggested in the analysis of mHRV in the study. ECG recordings from human subjects and dogs were used to further assess the effectiveness of the proposed method. The pilot study demonstrated that the proposed analysis of mHRV could provide more accurate assessment of the dynamical changes in cardiac activity than the conventional measures of HRV (without time overlapping. The proposed method may provide an efficient means in delineating the dynamics of momentary HRV and it would be worthy performing more investigations.

  3. Dynamic neural networking as a basis for plasticity in the control of heart rate.

    Science.gov (United States)

    Kember, G; Armour, J A; Zamir, M

    2013-01-21

    A model is proposed in which the relationship between individual neurons within a neural network is dynamically changing to the effect of providing a measure of "plasticity" in the control of heart rate. The neural network on which the model is based consists of three populations of neurons residing in the central nervous system, the intrathoracic extracardiac nervous system, and the intrinsic cardiac nervous system. This hierarchy of neural centers is used to challenge the classical view that the control of heart rate, a key clinical index, resides entirely in central neuronal command (spinal cord, medulla oblongata, and higher centers). Our results indicate that dynamic networking allows for the possibility of an interplay among the three populations of neurons to the effect of altering the order of control of heart rate among them. This interplay among the three levels of control allows for different neural pathways for the control of heart rate to emerge under different blood flow demands or disease conditions and, as such, it has significant clinical implications because current understanding and treatment of heart rate anomalies are based largely on a single level of control and on neurons acting in unison as a single entity rather than individually within a (plastically) interconnected network. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Heart Rate Monitors Promote Physical Education for Children

    Science.gov (United States)

    Tipton, Jan; Sander, Allan N.

    2004-01-01

    National health and fitness data suggests that a significant percentage of children are not on a pathway to leading healthy, physically active lifestyles. Many children are leading sedentary lifestyles due to a lack of opportunity, success, or self-motivation in physical activity. Programs that highlight the use of heart rate monitors offer a…

  5. Influence of Prolonged Spaceflight on Heart Rate and Oxygen Uptake Kinetics

    Science.gov (United States)

    Hoffmann, U.; Moore, A.; Drescher, U.

    2013-02-01

    During prolonged spaceflight, physical training is used to minimize cardiovascular deconditioning. Measurement of the kinetics of cardiorespiratory parameters, in particular the kinetic analysis of heart rate, respiratory and muscular oxygen uptake, provides useful information with regard to the efficiency and regulation of the cardiorespiratory system. Practically, oxygen uptake kinetics can only be measured at the lung site (V’O2 resp). The dynamics of V’O2 resp, however, is not identical with the dynamics at the site of interest: skeletal muscle. Eight Astronauts were tested pre- and post-flight using pseudo random binary workload changes between 30 and 80 W. Their kinetic responses of heart rate, respiratory as well as muscular V’O2 kinetics were estimated by using time-series analysis. Statistical analysis revealed that the kinetic responses of respiratory as well as muscular V’O2 kinetics are slowed post-flight than pre-flight. Heart rate seems not to be influenced following flight. The influence of other factors (e. g. astronauts’ exercise training) may impact these parameters and is an area for future studies.

  6. Estimation of physical work load by statistical analysis of the heart rate in a conveyor-belt worker.

    Science.gov (United States)

    Kontosic, I; Vukelić, M; Pancić, M; Kunisek, J

    1994-12-01

    Physical work load was estimated in a female conveyor-belt worker in a bottling plant. Estimation was based on continuous measurement and on calculation of average heart rate values in three-minute and one-hour periods and during the total measuring period. The thermal component of the heart rate was calculated by means of the corrected effective temperature, for the one-hour periods. The average heart rate at rest was also determined. The work component of the heart rate was calculated by subtraction of the resting heart rate and the heart rate measured at 50 W, using a regression equation. The average estimated gross energy expenditure during the work was 9.6 +/- 1.3 kJ/min corresponding to the category of light industrial work. The average estimated oxygen uptake was 0.42 +/- 0.06 L/min. The average performed mechanical work was 12.2 +/- 4.2 W, i.e. the energy expenditure was 8.3 +/- 1.5%.

  7. Changes in heart rate and heart rate variability during transportation of horses by road and air.

    Science.gov (United States)

    Ohmura, Hajime; Hobo, Seiji; Hiraga, Atsushi; Jones, James H

    2012-04-01

    To determine the influence of transportation by road and air on heart rate (HR) and HR variability (HRV) in horses. Animals-6 healthy horses. ECG recordings were obtained from horses before (quarantine with stall rest [Q]; 24 hours) and during a journey that included transportation by road (RT; 4.5 hours), waiting on the ground in an air stall (W; 5.5 hours), and transportation by air (AT; 11 hours); HR was determined, and HRV indices of autonomic nervous activity (low-frequency [LF; 0.01 to 0.07 Hz] and high-frequency [HF; 0.07 to 0.6 Hz] power) were calculated. Mean ± SD HRs during Q, RT, W, and AT were 38.9 ± 1.5 beats/min, 41.7 ± 5.6 beats/min, 41.5 ± 4.3 beats/min, and 48.8 ± 5.6 beats/min, respectively; HR during AT was significantly higher than HR during Q. The LF power was significantly higher during Q (3,454 ± 1,087 milliseconds(2)) and AT (3,101 ± 567 milliseconds(2)) than it was during RT (1,824 ± 432 milliseconds(2)) and W (2,072 ± 616 milliseconds(2)). During Q, RT, W, and AT, neither HF powers (range, 509 to 927 milliseconds(2)) nor LF:HF ratios (range, 4.1 to 6.2) differed significantly. The HR during RT was highly correlated with LF power (R(2) = 0.979), and HR during AT was moderately correlated with the LF:HF ratio (R(2) = 0.477). In horses, HR and HRV indices during RT and AT differed, suggesting that exposure to different stressors results in different autonomic nervous influences on HR.

  8. [Evaluation of heart impact in the 100 m extreme intensity sport using near-infrared non-invasive muscle oxygen detecting device and sports heart rate detection technology].

    Science.gov (United States)

    Wang, Pei-Yong; Long, Fei-Xiao; Fu, Lan-Ying; Li, Yue; Ding, Hai-Shu; Qu, An-Lian; Zhou, Xiao-Ping

    2010-02-01

    Using continuous two wavelength near-infrared technology to detect the variation in the consistency of oxygen hemoglobin in the muscle and the sports heart rate wireless real time collection technology, we devised the real time muscle tissue oxygenation and instantaneous heart rate experiment scheme and implemented it for the process of the 100 m run with two parameters given simultaneously. The experiment shows that the concentration of the oxygen hemoglobin in the muscle tissue continues decreasing after the end of the 100 m run, and the time interval between the moment when the concentration of the oxygen hemoglobin attains the minimum value and the moment when the athletes finish the 100 m run is (6.65 +/- 1.10) sec; while the heart rate continues increasing after the end of the 100 m run, and the time interval between the moment when the heart rate attains the maximum value and the moment when the athletes finish the 100 m run is (8.00 +/- 1.57) sec. The results show that the two wavelength near-infrared tissue oxygenation detection technology and the sports heart rate real time collection equipment can accurately measure the sports tissue oxygenation and the heart rate in the extreme intensity sport, and reveal the process of muscle oxygen transportation and consumption and its dynamic character with the heart rate in the extreme intensity sport.

  9. Using pupil size and heart rate to infer affective states during behavioral neurophysiology and neuropsychology experiments.

    Science.gov (United States)

    Mitz, Andrew R; Chacko, Ravi V; Putnam, Philip T; Rudebeck, Peter H; Murray, Elisabeth A

    2017-03-01

    Nonhuman primates (NHPs) are a valuable research model because of their behavioral, physiological and neuroanatomical similarities to humans. In the absence of language, autonomic activity can provide crucial information about cognitive and affective states during single-unit recording, inactivation and lesion studies. Methods standardized for use in humans are not easily adapted to NHPs and detailed guidance has been lacking. We provide guidance for monitoring heart rate and pupil size in the behavioral neurophysiology setting by addressing the methodological issues, pitfalls and solutions for NHP studies. The methods are based on comparative physiology to establish a rationale for each solution. We include examples from both electrophysiological and lesion studies. Single-unit recording, pupil responses and heart rate changes represent a range of decreasing temporal resolution, a characteristic that impacts experimental design and analysis. We demonstrate the unexpected result that autonomic measures acquired before and after amygdala lesions are comparable despite disruption of normal autonomic function. Species and study design differences can render standard techniques used in human studies inappropriate for NHP studies. We show how to manage data from small groups typical of NHP studies, data from the short behavioral trials typical of neurophysiological studies, issues associated with longitudinal studies, and differences in anatomy and physiology. Autonomic measurement to infer cognitive and affective states in NHP is neither off-the-shelf nor onerous. Familiarity with the issues and solutions will broaden the use of autonomic signals in NHP single unit and lesion studies. Published by Elsevier B.V.

  10. The modulatory effects of noradrenaline on vagal control of heart rate in the dogfish, Squalus acanthias.

    Science.gov (United States)

    Agnisola, Claudio; Randall, David J; Taylor, Edwin W

    2003-01-01

    The possible interactions between inhibitory vagal control of the heart and circulating levels of catecholamines in dogfish (Squalus acanthias) were studied using an in situ preparation of the heart, which retained intact its innervation from centrally cut vagus nerves. The response to peripheral vagal stimulation typically consisted of an initial cardiac arrest, followed by an escape beat, leading to renewed beating at a mean heart rate lower than the prestimulation rate (partial recovery). Cessation of vagal stimulation led to a transient increase in heart rate, above the prestimulation rate. This whole response was completely abolished by 10(-4) M atropine (a muscarinic cholinergic antagonist). The degree of vagal inhibition was evaluated in terms of both the initial, maximal cardiac interval and the mean heart rate during partial recovery, both expressed as a percentage of the prestimulation heart rate. The mean prestimulation heart rate of this preparation (36+/-4 beats min(-1)) was not affected by noradrenaline but was significantly reduced by 10(-4) M nadolol (a beta-adrenergic receptor antagonist), suggesting the existence of a resting adrenergic tone arising from endogenous catecholamines. The degree of vagal inhibition of heart rate varied with the rate of stimulation and was increased by the presence of 10(-8) M noradrenaline (the normal in vivo level in routinely active fish), while 10(-7) M noradrenaline (the in vivo level measured in disturbed or deeply hypoxic fish) reduced the cardiac response to vagal stimulation. In the presence of 10(-7) M noradrenaline, 10(-4) M nadolol further reduced the vagal response, while 10(-4) M nadolol + 10(-4) M phentolamine had no effect, indicating a complex interaction between adrenoreceptors, possibly involving presynaptic modulation of vagal inhibition.

  11. Heart rate during conflicts predicts post-conflict stress-related behavior in greylag geese.

    Directory of Open Access Journals (Sweden)

    Claudia A F Wascher

    Full Text Available BACKGROUND: Social stressors are known to be among the most potent stressors in group-living animals. This is not only manifested in individual physiology (heart rate, glucocorticoids, but also in how individuals behave directly after a conflict. Certain 'stress-related behaviors' such as autopreening, body shaking, scratching and vigilance have been suggested to indicate an individual's emotional state. Such behaviors may also alleviate stress, but the behavioral context and physiological basis of those behaviors is still poorly understood. METHODOLOGY/PRINCIPAL FINDINGS: We recorded beat-to-beat heart rates (HR of 22 greylag geese in response to agonistic encounters using fully implanted sensor-transmitter packages. Additionally, for 143 major events we analyzed the behavior shown by our focal animals in the first two minutes after an interaction. Our results show that the HR during encounters and characteristics of the interaction predicted the frequency and duration of behaviors shown after a conflict. CONCLUSIONS/SIGNIFICANCE: To our knowledge this is the first study to quantify the physiological and behavioral responses to single agonistic encounters and to link this to post conflict behavior. Our results demonstrate that 'stress-related behaviors' are flexibly modulated by the characteristics of the preceding aggressive interaction and reflect the individual's emotional strain, which is linked to autonomic arousal. We found no support for the stress-alleviating hypothesis, but we propose that stress-related behaviors may play a role in communication with other group members, particularly with pair-partners.

  12. Heart Transplantation - Spectral and Bispectral Analysis

    National Research Council Canada - National Science Library

    Toledo, E

    2001-01-01

    .... 25 recordings were obtained from 13 male HT patients at time after transplant (TAT) ranging 0.5-65 months. We observed an interesting evolution with TAT in heart rate response to active standing...

  13. Heart Disease Death Rates Among Blacks and Whites Aged ≥35 Years — United States, 1968–2015

    Science.gov (United States)

    Van Dyke, Miriam; Greer, Sophia; Odom, Erika; Schieb, Linda; Vaughan, Adam; Kramer, Michael; Casper, Michele

    2018-01-01

    Problem/Condition Heart disease is the leading cause of death in the United States. In 2015, heart disease accounted for approximately 630,000 deaths, representing one in four deaths in the United States. Although heart disease death rates decreased 68% for the total population from 1968 to 2015, marked disparities in decreases exist by race and state. Period Covered 1968–2015. Description of System The National Vital Statistics System (NVSS) data on deaths in the United States were abstracted for heart disease using diagnosis codes from the eighth, ninth, and tenth revisions of the International Classification of Diseases (ICD-8, ICD-9, and ICD-10) for 1968–2015. Population estimates were obtained from NVSS files. National and state-specific heart disease death rates for the total population and by race for adults aged ≥35 years were calculated for 1968–2015. National and state-specific black-white heart disease mortality ratios also were calculated. Death rates were age standardized to the 2000 U.S. standard population. Joinpoint regression was used to perform time trend analyses. Results From 1968 to 2015, heart disease death rates decreased for the total U.S. population among adults aged ≥35 years, from 1,034.5 to 327.2 per 100,000 population, respectively, with variations in the magnitude of decreases by race and state. Rates decreased for the total population an average of 2.4% per year, with greater average decreases among whites (2.4% per year) than blacks (2.2% per year). At the national level, heart disease death rates for blacks and whites were similar at the start of the study period (1968) but began to diverge in the late 1970s, when rates for blacks plateaued while rates for whites continued to decrease. Heart disease death rates among blacks remained higher than among whites for the remainder of the study period. Nationwide, the black-white ratio of heart disease death rates increased from 1.04 in 1968 to 1.21 in 2015, with large increases

  14. A pilot investigation of the effect of extremely low frequency pulsed electromagnetic fields on humans' heart rate variability.

    Science.gov (United States)

    Baldi, Emilio; Baldi, Claudio; Lithgow, Brian J

    2007-01-01

    The question whether pulsed electromagnetic field (PEMF) can affect the heart rhythm is still controversial. This study investigates the effects on the cardiocirculatory system of ELF-PEMFs. It is a follow-up to an investigation made of the possible therapeutic effect ELF-PEMFs, using a commercially available magneto therapeutic unit, had on soft tissue injury repair in humans. Modulation of heart rate (HR) or heart rate variability (HRV) can be detected from changes in periodicity of the R-R interval and/or from changes in the numbers of heart-beat/min (bpm), however, R-R interval analysis gives only a quantitative insight into HRV. A qualitative understanding of HRV can be obtained considering the power spectral density (PSD) of the R-R intervals Fourier transform. In this study PSD is the investigative tool used, more specifically the low frequency (LF) PSD and high frequency (HF) PSD ratio (LF/HF) which is an indicator of sympatho-vagal balance. To obtain the PSD value, variations of the R-R time intervals were evaluated from a continuously recorded ECG. The results show a HR variation in all the subjects when they are exposed to the same ELF-PEMF. This variation can be detected by observing the change in the sympatho-vagal equilibrium, which is an indicator of modulation of heart activity. Variation of the LF/HF PSD ratio mainly occurs at transition times from exposure to nonexposure, or vice versa. Also of interest are the results obtained during the exposure of one subject to a range of different ELF-PEMFs. This pilot study suggests that a full investigation into the effect of ELF-PEMFs on the cardiovascular system is justified.

  15. The forgotten role of central volume in low frequency oscillations of heart rate variability.

    Directory of Open Access Journals (Sweden)

    Manuela Ferrario

    Full Text Available The hypothesis that central volume plays a key role in the source of low frequency (LF oscillations of heart rate variability (HRV was tested in a population of end stage renal disease patients undergoing conventional hemodialysis (HD treatment, and thus subject to large fluid shifts and sympathetic activation. Fluid overload (FO in 58 chronic HD patients was assessed by whole body bioimpedance measurements before the midweek HD session. Heart Rate Variability (HRV was measured using 24-hour Holter electrocardiogram recordings starting before the same HD treatment. Time domain and frequency domain analyses were performed on HRV signals. Patients were retrospectively classified in three groups according to tertiles of FO normalized to the extracellular water (FO/ECW%. These groups were also compared after stratification by diabetes mellitus. Patients with the low to medium hydration status before the treatment (i.e. 1st and 2nd FO/ECW% tertiles showed a significant increase in LF power during last 30 min of HD compared to dialysis begin, while no significant change in LF power was seen in the third group (i.e. those with high pre-treatment hydration values. In conclusion, several mechanisms can generate LF oscillations in the cardiovascular system, including baroreflex feedback loops and central oscillators. However, the current results emphasize the role played by the central volume in determining the power of LF oscillations.

  16. The forgotten role of central volume in low frequency oscillations of heart rate variability.

    Science.gov (United States)

    Ferrario, Manuela; Moissl, Ulrich; Garzotto, Francesco; Cruz, Dinna N; Tetta, Ciro; Signorini, Maria G; Ronco, Claudio; Grassmann, Aileen; Cerutti, Sergio; Guzzetti, Stefano

    2015-01-01

    The hypothesis that central volume plays a key role in the source of low frequency (LF) oscillations of heart rate variability (HRV) was tested in a population of end stage renal disease patients undergoing conventional hemodialysis (HD) treatment, and thus subject to large fluid shifts and sympathetic activation. Fluid overload (FO) in 58 chronic HD patients was assessed by whole body bioimpedance measurements before the midweek HD session. Heart Rate Variability (HRV) was measured using 24-hour Holter electrocardiogram recordings starting before the same HD treatment. Time domain and frequency domain analyses were performed on HRV signals. Patients were retrospectively classified in three groups according to tertiles of FO normalized to the extracellular water (FO/ECW%). These groups were also compared after stratification by diabetes mellitus. Patients with the low to medium hydration status before the treatment (i.e. 1st and 2nd FO/ECW% tertiles) showed a significant increase in LF power during last 30 min of HD compared to dialysis begin, while no significant change in LF power was seen in the third group (i.e. those with high pre-treatment hydration values). In conclusion, several mechanisms can generate LF oscillations in the cardiovascular system, including baroreflex feedback loops and central oscillators. However, the current results emphasize the role played by the central volume in determining the power of LF oscillations.

  17. Interest of analyses of heart rate variability in the prevention of fatigue states in senior runners.

    Science.gov (United States)

    Leti, Thomas; Bricout, Véronique A

    2013-01-01

    The use of heart rate variability (HRV) in the management of sport training is a practice which tends to spread, especially in order to prevent the occurrence of fatigue states. To estimate the HRV parameters obtained using a heart rate recording, according to different exercise impacts, and to make the link with the appearance of subjective fatigue. Ten senior runners, aged 51±5 years, were each monitored over a period of 12 weeks in different conditions: (i) after a resting period, (ii) after a day with training, (iii) after a day of competition and (iv) after a rest day. They also completed three questionnaires, to assess fatigue (SFMS), profile of mood states (POMS) and quality of sleep. The HRV indices (heart rate, LF (n.u.), HF (n.u.) and LF/HF) were significantly altered with the competitive impact, shifting toward a sympathetic predominance. After rest and recovery nights, the LF (n.u.) increased significantly with the competitive impact (62.1±15.2 and 66.9±11.6 vs. 76.0±10.7; p<0.05 respectively) whereas the HF (n.u.) decreased significantly (37.9±15.2 and 33.1±11.6 vs. 24.0±10.7; p<0.05 respectively). Positive correlations were found between fatigue and frequency domain indices and between fatigue and training impact. Autonomic nervous system modulation-fatigue relationships were significant, suggesting the potential use of HRV in follow-up and control of training. Furthermore, the addition of questionnaires constitutes complementary tools that allow to achieve a greater relevance and accuracy of the athletes' fitness and results. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Electrodes as social glue: measuring heart rate promotes giving in the trust game.

    Science.gov (United States)

    Van Lange, Paul A M; Finkenauer, Catrin; Popma, Arne; van Vugt, Mark

    2011-06-01

    While physiological measures are increasingly used to help us understand the workings of interpersonal trust (and related behaviors), we know very little about the effects of such measures on trust. We examined the effects of a classic measure, the measurement of heart rate using a standard protocol, on behavioral trust in dyads of women who did not know each other. Behavioral trust was assessed in the trust game, in which the trustor decides how much money from their subject payment to give to a trustee, while knowing that the experimenter triples that amount before giving it to the trustee, after which the trustee decides how much money to return to the trustor. As predicted, we found greater levels of behavioral trust in the trust game, as well as greater returns by the trustees (which were accounted for by trustor's giving), in the heart rate (HR) than in no heart rate (NHR) measurement condition. Parallel findings were observed for self-reported trust. Findings are discussed in terms of the idea that the elusive effects of a protocol for measuring heart rate can cause pronounced effects on subsequent social interactions via enhanced interpersonal trust. 2011 Elsevier B.V. All rights reserved.

  19. Heart rate responses to autonomic challenges in obstructive sleep apnea.

    Directory of Open Access Journals (Sweden)

    Paul M Macey

    Full Text Available Obstructive sleep apnea (OSA is accompanied by structural alterations and dysfunction in central autonomic regulatory regions, which may impair dynamic and static cardiovascular regulation, and contribute to other syndrome pathologies. Characterizing cardiovascular responses to autonomic challenges may provide insights into central nervous system impairments, including contributions by sex, since structural alterations are enhanced in OSA females over males. The objective was to assess heart rate responses in OSA versus healthy control subjects to autonomic challenges, and, separately, characterize female and male patterns. We studied 94 subjects, including 37 newly-diagnosed, untreated OSA patients (6 female, age mean ± std: 52.1 ± 8.1 years; 31 male aged 54.3 ± 8.4 years, and 57 healthy control subjects (20 female, 50.5 ± 8.1 years; 37 male, 45.6 ± 9.2 years. We measured instantaneous heart rate with pulse oximetry during cold pressor, hand grip, and Valsalva maneuver challenges. All challenges elicited significant heart rate differences between OSA and control groups during and after challenges (repeated measures ANOVA, p<0.05. In post-hoc analyses, OSA females showed greater impairments than OSA males, which included: for cold pressor, lower initial increase (OSA vs. control: 9.5 vs. 7.3 bpm in females, 7.6 vs. 3.7 bpm in males, OSA delay to initial peak (2.5 s females/0.9 s males, slower mid-challenge rate-of-increase (OSA vs. control: -0.11 vs. 0.09 bpm/s in females, 0.03 vs. 0.06 bpm/s in males; for hand grip, lower initial peak (OSA vs. control: 2.6 vs. 4.6 bpm in females, 5.3 vs. 6.0 bpm in males; for Valsalva maneuver, lower Valsalva ratio (OSA vs. control: 1.14 vs. 1.30 in females, 1.29 vs. 1.34 in males, and OSA delay during phase II (0.68 s females/1.31 s males. Heart rate responses showed lower amplitude, delayed onset, and slower rate changes in OSA patients over healthy controls, and impairments may be more pronounced in

  20. Association between smoking and heart rate variability among individuals with depression.

    Science.gov (United States)

    Harte, Christopher B; Liverant, Gabrielle I; Sloan, Denise M; Kamholz, Barbara W; Rosebrock, Laina E; Fava, Maurizio; Kaplan, Gary B

    2013-08-01

    Both depression and smoking have been independently associated with lower heart rate variability (HRV), suggesting dysregulation of cardiac autonomic function. However, no studies have systematically explored the effects of smoking on HRV among depressed patients. This study examined differences in HRV based on smoking status among depressed individuals. Electrophysiological data were examined among 77 adult outpatients without a history of myocardial infarction, who met criteria for major depressive disorder or dysthymia. Frequency domain [low frequency (LF), high frequency (HF), LF/HF ratio, respiratory sinus arrhythmia (RSA)] parameters of HRV, and heart rate and inter-beat interval (IBI) data were compared between depressed smokers (n = 34) and depressed nonsmokers (n = 44). After controlling for covariates, depressed smokers, compared to depressed nonsmokers, displayed significantly lower LF, HF, and RSA. Among depressed patients, smoking is associated with significantly lower HRV, indicating dysregulated autonomic modulation of the heart.

  1. Reduced dietary sodium intake increases heart rate. A meta-analysis of 63 randomized controlled trials including 72 study populations.

    Directory of Open Access Journals (Sweden)

    Niels eGraudal

    2016-03-01

    Full Text Available Reduced dietary sodium intake (sodium reduction increases heart rate in some studies of animals and humans. As heart rate is independently associated with the development of heart failure and increased risk of premature death a potential increase in heart rate could be a harmful side-effect of sodium reduction. The purpose of the present meta-analysis was to investigate the effect of sodium reduction on heart rate. Relevant studies were retrieved from an updated pool of 176 randomized controlled trials (RCTs published in the period 1973–2014. 63 of the RCTs including 72 study populations reported data on heart rate. In a meta-analysis of these data sodium reduction increased heart rate with 1.65 beats per minute [95% CI: 1.19, 2.11], p < 0.00001, corresponding to 2.4% of the baseline heart rate. This effect was independent of baseline blood pressure. In conclusion sodium reduction increases heart rate by as much (2.4% as it decreases blood pressure (2.5%. This side-effect, which may cause harmful health effects, contributes to the need for a revision of the present dietary guidelines.

  2. Heart rate variability is reduced during acute uncomplicated diverticulitis

    DEFF Research Database (Denmark)

    Huang, Chenxi; Alamili, Mahdi; Rosenberg, Jacob

    2016-01-01

    BACKGROUND: The aim of the present study was to report the trajectory of heart rate variability (HRV) indices during a low-grade acute inflammation and their associations to biomarkers for infection. METHODS: Twelve patients with uncomplicated acute diverticulitis completed this observational study...

  3. Physiological and performance adaptations to an in-season soccer camp in the heat: Associations with heart rate and heart rate variability

    DEFF Research Database (Denmark)

    Buchheit, M; Voss, S C; Nybo, Lars

    2011-01-01

    The aim of the present study was to examine the associations between adaptive responses to an in-season soccer training camp in the heat and changes in submaximal exercising heart rate (HRex, 5-min run at 9 ¿km/h), postexercise HR recovery (HRR) and HR variability (HRV). Fifteen well-trained but ......The aim of the present study was to examine the associations between adaptive responses to an in-season soccer training camp in the heat and changes in submaximal exercising heart rate (HRex, 5-min run at 9 ¿km/h), postexercise HR recovery (HRR) and HR variability (HRV). Fifteen well......-trained but non-heat-acclimatized male adult players performed a training week in Qatar (34.6¿±¿1.9°C wet bulb globe temperature). HRex, HRR, HRV (i.e. the standard deviation of instantaneous beat-to-beat R-R interval variability measured from Poincaré plots SD1, a vagal-related index), creatine kinase (CK...... at the beginning and at the end of the training week. Throughout the intervention, HRex and HRV showed decreasing (P¿...

  4. The Influence of a Mouthpiece-Based Topography Measurement Device on Electronic Cigarette User's Plasma Nicotine Concentration, Heart Rate, and Subjective Effects Under Directed and Ad Libitum Use Conditions.

    Science.gov (United States)

    Spindle, Tory R; Hiler, Marzena M; Breland, Alison B; Karaoghlanian, Nareg V; Shihadeh, Alan L; Eissenberg, Thomas

    2017-04-01

    Electronic cigarettes e-cigarettes aerosolize a liquid solution often containing nicotine. e-cigarette nicotine delivery may be influenced by user puffing behaviors ("puff topography"). E-cigarette puff topography can be recorded using mouthpiece-based computerized systems. The present study sought to examine the extent to which these systems influence e-cigarette nicotine delivery and other e-cigarette associated acute effects under ad libitum use conditions. Plasma nicotine concentration, heart rate, and subjective effects were assessed in 29 experienced e-cigarette users using their preferred e-cigarette battery and liquid (≥12mg/mL nicotine) in two sessions differing only by the presence of a mouthpiece-based device. In both sessions, participants completed a directed e-cigarette use bout (10 puffs, 30-s interpuff interval) and a 90-min ad libitum bout. Puff topography was recorded in the session with the topography mouthpiece. Plasma nicotine, heart rate, and subjective effects, aside from "Did the e-cigarette Taste Good?" were independent of topography measurement (higher mean taste ratings were observed in the no topography condition). Mean (SEM) plasma nicotine concentration following the ad libitum bout was 34.3ng/mL (4.9) in the no topography condition and 35.7ng/mL (4.3) in the topography condition. Longer puff durations, longer interpuff intervals, and larger puff volumes were observed in the ad libitum relative to the directed bout. E-cigarette use significantly increased plasma nicotine concentration and heart rate while suppressing abstinence symptoms. These effects did not differ when a topography mouthpiece was present. Future studies using ad libitum e-cigarette use bouts would facilitate understanding of e-cigarette toxicant yield. No prior study has examined whether mouthpiece-based topography recording devices influence e-cigarette associated nicotine delivery, heart rate, or subjective effects under ad libitum conditions or assessed ad

  5. Prognostic value of ambulatory heart rate revisited in 6928 subjects from 6 populations

    DEFF Research Database (Denmark)

    Hansen, Tine Willum; Thijs, Lutgarde; Staessen, Jan A.

    2008-01-01

    The evidence relating mortality and morbidity to heart rate remains inconsistent. We performed 24-hour ambulatory blood pressure monitoring in 6928 subjects (not on beta-blockers; mean age: 56.2 years; 46.5% women) enrolled in prospective population studies in Denmark, Belgium, Japan, Sweden......, Uruguay, and China. We computed standardized hazard ratios for heart rate, while stratifying for cohort, and adjusting for blood pressure and other cardiovascular risk factors. Over 9.6 years (median), 850, 325, and 493 deaths accrued for total, cardiovascular, and noncardiovascular mortality......, respectively. The incidence of fatal combined with nonfatal end points was 805, 363, 439, and 324 for cardiovascular, stroke, cardiac, and coronary events, respectively. Twenty-four-hour heart rate predicted total (hazard ratio: 1.15) and noncardiovascular (hazard ratio: 1.18) mortality but not cardiovascular...

  6. MEDEX 2015: Heart Rate Variability Predicts Development of Acute Mountain Sickness.

    Science.gov (United States)

    Sutherland, Angus; Freer, Joseph; Evans, Laura; Dolci, Alberto; Crotti, Matteo; Macdonald, Jamie Hugo

    2017-09-01

    Sutherland, Angus, Joseph Freer, Laura Evans, Alberto Dolci, Matteo Crotti, and Jamie Hugo Macdonald. MEDEX 2015: Heart rate variability predicts development of acute mountain sickness. High Alt Med Biol. 18: 199-208, 2017. Acute mountain sickness (AMS) develops when the body fails to acclimatize to atmospheric changes at altitude. Preascent prediction of susceptibility to AMS would be a useful tool to prevent subsequent harm. Changes to peripheral oxygen saturation (SpO 2 ) on hypoxic exposure have previously been shown to be of poor predictive value. Heart rate variability (HRV) has shown promise in the early prediction of AMS, but its use pre-expedition has not previously been investigated. We aimed to determine whether pre- and intraexpedition HRV assessment could predict susceptibility to AMS at high altitude with better diagnostic accuracy than SpO 2 . Forty-four healthy volunteers undertook an expedition in the Nepali Himalaya to >5000 m. SpO 2 and HRV parameters were recorded at rest in normoxia and in a normobaric hypoxic chamber before the expedition. On the expedition HRV parameters and SpO 2 were collected again at 3841 m. A daily Lake Louise Score was obtained to assess AMS symptomology. Low frequency/high frequency (LF/HF) ratio in normoxia (cutpoint ≤2.28 a.u.) and LF following 15 minutes of exposure to normobaric hypoxia had moderate (area under the curve ≥0.8) diagnostic accuracy. LF/HF ratio in normoxia had the highest sensitivity (85%) and specificity (88%) for predicting AMS on subsequent ascent to altitude. In contrast, pre-expedition SpO 2 measurements had poor (area under the curve <0.7) diagnostic accuracy and inferior sensitivity and specificity. Pre-ascent measurement of HRV in normoxia was found to be of better diagnostic accuracy for AMS prediction than all measures of HRV in hypoxia, and better than peripheral oxygen saturation monitoring.

  7. Variation in heart rate and blood lactate concentration in freestyle kytesurfing.

    Science.gov (United States)

    Camps, A; Vercruyssen, F; Brisswalter, J

    2011-06-01

    The aim of this paper was to evaluate the physiological demands of freestyle kitesurfing. Ten elite subjects performed an incremental running test on a treadmill and a three 7 min simulated freestyle heats of kitesurfing in MW (Midwind) condition ranging from 15 to 22 knots. Oxygen uptake (VO(2)) was estimated from the heart rate (HR) recorded during the freestyle trial using the individual HR-VO(2) relationship determined during the incremental test. Blood lactate concentration [Lab] was measured at rest and 3 min after the exercise completion. 3 experienced kitesurfers acted as judges to better simulate competition conditions. Linear relationship was demonstrated between scores and % HR(max) on water (r=-0.764, Pat the end of crossing trial (5.2±0.8 mmol L(-1)). This first analysis of freestyle kitesurfing suggests that the energy demand is sustained by both aerobic and anaerobic metabolism during a MW condition and freestyle event of kitesurfing.

  8. Heart Rate Variability: New Perspectives on Physiological Mechanisms, Assessment of Self-regulatory Capacity, and Health risk.

    Science.gov (United States)

    McCraty, Rollin; Shaffer, Fred

    2015-01-01

    Heart rate variability, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operates on different time scales to adapt to environmental and psychological challenges. This article briefly reviews neural regulation of the heart and offers some new perspectives on mechanisms underlying the very low frequency rhythm of heart rate variability. Interpretation of heart rate variability rhythms in the context of health risk and physiological and psychological self-regulatory capacity assessment is discussed. The cardiovascular regulatory centers in the spinal cord and medulla integrate inputs from higher brain centers with afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. We also discuss the intrinsic cardiac nervous system and the heart-brain connection pathways, through which afferent information can influence activity in the subcortical, frontocortical, and motor cortex areas. In addition, the use of real-time HRV feedback to increase self-regulatory capacity is reviewed. We conclude that the heart's rhythms are characterized by both complexity and stability over longer time scales that reflect both physiological and psychological functional status of these internal self-regulatory systems.

  9. Reduced heart rate variability and vagal tone in anxiety: trait versus state, and the effects of autogenic training.

    Science.gov (United States)

    Miu, Andrei C; Heilman, Renata M; Miclea, Mircea

    2009-01-28

    This study investigated heart rate variability (HRV) in healthy volunteers that were selected for extreme scores of trait anxiety (TA), during two opposite psychophysiological conditions of mental stress, and relaxation induced by autogenic training. R-R intervals, HF and LF powers, and LF/HF ratios were derived from short-term electrocardiographic recordings made during mental stress and relaxation by autogenic training, with respiratory rate and skin conductance being controlled for in all the analyses. The main finding was that high TA was associated with reduced R-R intervals and HF power across conditions. In comparison to mental stress, autogenic training increased HRV and facilitated the vagal control of the heart. There were no significant effects of TA or the psychophysiological conditions on LF power, or LF/HF ratio. These results support the view that TA, which is an important risk factor for anxiety disorders and predictor of cardiovascular morbidity and mortality, is associated with autonomic dysfunction that seems likely to play a pathogenetic role in the long term.

  10. Gonadal hormones and heart rate as an emotional response

    NARCIS (Netherlands)

    de Loos, Wolter Statius

    1988-01-01

    Animai experiments may give information on the physiology of hormones under stress conditions. The model for the investigation of acute emotional stress in animals that has been chosen permits the study of heart rate in freely moving laboratory rats as a sensitive psychophysiological parameter, This

  11. Blood pressure and heart rate adjustment following acute Frenkel's ...

    African Journals Online (AJOL)

    Background: Frenkel's ambulatory activity has been routinely employed by physiotherapists for rehabilitation of gait coordination, however, its immediate influence on blood pressure and heart rate has not been investigated. Objective: To investigate the acute effect of Frenkel's ambulatory activity on blood pressure and ...

  12. Heart Rate and Oxygen Saturation Change Patterns During 6-min Walk Test in Subjects With Chronic Thromboembolic Pulmonary Hypertension.

    Science.gov (United States)

    Inagaki, Takeshi; Terada, Jiro; Yahaba, Misuzu; Kawata, Naoko; Jujo, Takayuki; Nagashima, Kengo; Sakao, Seiichiro; Tanabe, Nobuhiro; Tatsumi, Koichiro

    2017-12-26

    The 6-min walk test (6MWT) is commonly performed to assess functional status in patients with chronic thromboembolic pulmonary hypertension. However, changes in heart rate and oxygen saturation ( S pO 2 ) patterns during 6MWT in patients with chronic thromboembolic pulmonary hypertension remain unclear. Thirty-one subjects with chronic thromboembolic pulmonary hypertension were retrospectively evaluated to examine the relationships between the change in heart rateheart rate), heart rate acceleration time, slope of heart rate acceleration, heart rate recovery during the first minute after 6MWT (HRR1), change in S pO 2 (Δ S pO 2 ), S pO 2 reduction time, and S pO 2 recovery time during 6MWT, and the severity of pulmonary hemodynamics assessed by right heart catheterization and echocardiography. Subjects with severe chronic thromboembolic pulmonary hypertension had significantly longer heart rate acceleration time (144.9 ± 63.9 s vs 96.0 ± 42.5 s, P = .033), lower Δheart rate (47.4 ± 16.9 vs 61.8 ± 13.6 beats, P = .02), and lower HRR1 (13.3 ± 9.0 beats vs 27.1 ± 9.2 beats, P pulmonary hypertension. Subjects with severe chronic thromboembolic pulmonary hypertension also had significantly longer S pO 2 reduction time (178.3 ± 70.3 s vs 134.3 ± 58.4 s, P = .03) and S pO 2 recovery time (107.6 ± 35.3 s vs 69.8 ± 32.7 s, P = .004) than did subjects with mild chronic thromboembolic pulmonary hypertension. Multivariate linear regression analysis showed only mean pulmonary arterial pressure independently was associated with heart rate acceleration time and slope of heart rate acceleration. Heart rate and S pO 2 change patterns during 6MWT is predominantly associated with pulmonary hemodynamics in subjects with chronic thromboembolic pulmonary hypertension. Evaluating heart rate and S pO 2 change patterns during 6MWT may serve a safe and convenient way to follow the change in pulmonary hemodynamics. Copyright © 2017 by Daedalus Enterprises.

  13. A healthy heart is not a metronome: An integrative review of the heart’s anatomy and heart rate variability

    Directory of Open Access Journals (Sweden)

    Fredric Bruce Shaffer

    2014-09-01

    Full Text Available Heart rate variability (HRV, the change in the time intervals between adjacent heartbeats, is an emergent property of interdependent regulatory systems that operate on different time scales to adapt to challenges and achieve optimal performance. This article briefly reviews neural regulation of the heart, and its basic anatomy, the cardiac cycle, and the sinoatrial and atrioventricular pacemakers. The cardiovascular regulation center in the medulla integrates sensory information and input from higher brain centers, and afferent cardiovascular system inputs to adjust heart rate and blood pressure via sympathetic and parasympathetic efferent pathways. This article reviews sympathetic and parasympathetic influences on the heart, and examines the interpretation of HRV and the association between reduced HRV, risk of disease and mortality, and the loss of regulatory capacity. This article also discusses the intrinsic cardiac nervous system and the heart-brain connection, through which afferent information can influence activity in the subcortical and frontocortical areas, and motor cortex. It also considers new perspectives on the putative underlying physiological mechanisms and properties of the ultra-low-frequency (ULF, very-low-frequency (VLF, low-frequency (LF, and high-frequency (HF bands. Additionally, it reviews the most common time and frequency domain measurements as well as standardized data collection protocols. In its final section, this article integrates Porges’ polyvagal theory, Thayer and colleagues’ neurovisceral integration model, Lehrer, Vaschillo, and Vaschillo’s resonance frequency model, and the Institute of HeartMath’s coherence model. The authors conclude that a coherent heart is not a metronome because its rhythms are characterized by both complexity and stability over longer time scales. Future research should expand understanding of how the heart and its intrinsic nervous system influence the brain.

  14. Heart rate variability alters cardiac repolarization and electromechanical dynamics.

    Science.gov (United States)

    Phadumdeo, Vrishti M; Weinberg, Seth H

    2018-04-07

    Heart rate continuously varies due to autonomic regulation, stochasticity in pacemaking, and circadian rhythm, collectively termed heart rate variability (HRV), during normal physiological conditions. Low HRV is clinically associated with an elevated risk of cardiac arrhythmias. Alternans, a beat-to-beat alternation in action potential duration (APD) and/or intracellular calcium (Ca) transient, is a well-known risk factor associated with cardiac arrhythmias that is typically studied under conditions of a constant pacing rate, i.e., the absence of HRV. In this study, we investigate the effects of HRV on the interplay between APD, Ca, and electromechanical properties, employing a nonlinear discrete-time map model that governs APD and intracellular Ca cycling with a stochastic pacing period. We find that HRV can decrease variation in APD and peak Ca at fast pacing rates for which alternans is present. Further, increased HRV typically disrupts the alternating pattern for both APD and peak Ca and weakens the correlation between APD and peak Ca, thus decoupling Ca-mediated instabilities from repolarization alternation. We find that the efficacy of these effects is regulated by the sarcoplasmic reticulum Ca uptake rate. Overall, these results demonstrate that HRV disrupts arrhythmogenic alternans and suggests that HRV may be a significant factor in preventing life-threatening arrhythmias. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Change in heart rate variability after the adult attachment interview in dissociative patients.

    Science.gov (United States)

    Farina, Benedetto; Speranza, Anna Maria; Imperatori, Claudio; Quintiliani, Maria Isabella; Della Marca, Giacomo

    2015-01-01

    The aim of this study was to assess heart rate variability (HRV) in individuals with dissociative disorders (DD) before and after the Adult Attachment Interview (AAI). Electrocardiograms were recorded before, during, and after the AAI in 13 individuals with DD and 13 healthy participants matched for age and gender. Significant change in HRV was observed only in the DD group. After the AAI, those with DD showed significant increases in the low frequency/high frequency ratio (pre-AAI = 1.91 ± 1.19; post-AAI = 4.03 ± 2.40; Wilcoxon test = -2.76, p = .005). Our results suggest that the retrieval of childhood attachment experiences in individuals with DD is associated with a change in HRV patterns that could reflect the emotion dysregulation of dissociative psychopathological processes.

  16. Evaluation of the influence of change in heart rate on left ventricular diastolic function indices

    International Nuclear Information System (INIS)

    Kimura, Motomasa; Yamagishi, Hiroaki; Seino, Yasuyuki; Odano, Ikuo; Sakai, Kunio; Yamamoto, Tomohiko; Tsuda, Takashi

    1988-01-01

    In order to assess the influence of change in heart rate on left ventricular diastolic function indices, ECG gated cardiac pool study was performed in 6 patients with implanted programmable AAI pacemakers. Heart rate was changed by atrial pacing from 50 to 120 beats/min, every 10 beats/min. The filling fraction during first third of diastole (1/3FF), the peak filling rate (PFR), mean first third filling rate (1/3FR-mean) and early filling volume ratio (%EFV), being used as the indices of left ventricular diastolic performance, were assessed. In accordance with increase in heart rate, 1/3FF decreased significantly. PFR were fairly stable from 50 to 80 beats/min, but increased significantly from 90 to 120 beats/min. 1/3FR-mean and %EFV did not change significantly, but 1/3FR-mean showed decreasing tendency and %EFV showed increasing tendency as the heart rate was increased. %EFV was more changeable index than other indices among clinical cases. These results indicate that PFR and 1/3FR-mean were appropriate diastolic phase indices at rest. (author)

  17. Investigation of effect of blood pressure and heart rate changes in different positions (lying and sitting on hypotension incidence rate after spinal anesthesia in patients undergoing caesarean section

    Directory of Open Access Journals (Sweden)

    Nahid Manouchehrian

    2016-07-01

    Full Text Available Due to the relatively high prevalence of hypotension (20% -40% after spinal anesthesia as well as the adverse effects of hypotension on mother and baby, it is better to prevent hypotension as much as possible. Therefore, this study is aimed to determine the relationship between postural blood pressure and heart rate changes and hypotension incidence rate after spinal anesthesia in cesarean section.63 women aging18 to 45years old with fullterm pregnancy, who were candidate for caesarean section with spinal anesthesia, entered the study. Afterwards, the diastolic, systolic, and mean arterial pressures as well as the heart rate (pulse in different positions (sitting, lying, and left lateral were measured. After spinal anesthesia, the patients' blood pressure was measured and recorded every minute until the10thmin, then every 3 minute until the15thmin, and then every 5 minute until the end of cesarean section. Data analysis was performed using SPSS (ver. 19 software, descriptive statistics, one-way ANOVA, and post hoc Bonferroni test. In this study, the hypotension incidence rate was 30% and the orthostatic variation rate of the systolic blood pressure in more than half of the people was between 4.39 to 13.49psi, which showed the highest variation compared to the diastolic pressure, mean arterial blood pressure (or: mean arterial pressure [MAP], and heart(pulse. Considering the correlation coefficient of 0.27, the systolic blood pressure in the lateral position has the highest relationship with the incidence of hypotension. The postural systolic blood pressure changes in patients prior to the spinal anesthesia can be a predictive factor for the post-spinal hypotension incidence.

  18. Wavelet and receiver operating characteristic analysis of heart rate variability

    Science.gov (United States)

    McCaffery, G.; Griffith, T. M.; Naka, K.; Frennaux, M. P.; Matthai, C. C.

    2002-02-01

    Multiresolution wavelet analysis has been used to study the heart rate variability in two classes of patients with different pathological conditions. The scale dependent measure of Thurner et al. was found to be statistically significant in discriminating patients suffering from hypercardiomyopathy from a control set of normal subjects. We have performed Receiver Operating Characteristc (ROC) analysis and found the ROC area to be a useful measure by which to label the significance of the discrimination, as well as to describe the severity of heart dysfunction.

  19. Promising effects of xanthine oxidase inhibition by allopurinol on autonomic heart regulation estimated by heart rate variability (HRV) analysis in rats exposed to hypoxia and hyperoxia

    Science.gov (United States)

    Ziółkowski, Wiesław; Badtke, Piotr; Zajączkowski, Miłosz A.; Flis, Damian J.; Figarski, Adam; Smolińska-Bylańska, Maria; Wierzba, Tomasz H.

    2018-01-01

    Background It has long been suggested that reactive oxygen species (ROS) play a role in oxygen sensing via peripheral chemoreceptors, which would imply their involvement in chemoreflex activation and autonomic regulation of heart rate. We hypothesize that antioxidant affect neurogenic cardiovascular regulation through activation of chemoreflex which results in increased control of sympathetic mechanism regulating heart rhythm. Activity of xanthine oxidase (XO), which is among the major endogenous sources of ROS in the rat has been shown to increase during hypoxia promote oxidative stress. However, the mechanism of how XO inhibition affects neurogenic regulation of heart rhythm is still unclear. Aim The study aimed to evaluate effects of allopurinol-driven inhibition of XO on autonomic heart regulation in rats exposed to hypoxia followed by hyperoxia, using heart rate variability (HRV) analysis. Material and methods 16 conscious male Wistar rats (350 g): control-untreated (N = 8) and pretreated with Allopurinol-XO inhibitor (5 mg/kg, followed by 50 mg/kg), administered intraperitoneally (N = 8), were exposed to controlled hypobaric hypoxia (1h) in order to activate chemoreflex. The treatment was followed by 1h hyperoxia (chemoreflex suppression). Time-series of 1024 RR-intervals were extracted from 4kHz ECG recording for heart rate variability (HRV) analysis in order to calculate the following time-domain parameters: mean RR interval (RRi), SDNN (standard deviation of all normal NN intervals), rMSSD (square root of the mean of the squares of differences between adjacent NN intervals), frequency-domain parameters (FFT method): TSP (total spectral power) as well as low and high frequency band powers (LF and HF). At the end of experiment we used rat plasma to evaluate enzymatic activity of XO and markers of oxidative stress: protein carbonyl group and 8-isoprostane concentrations. Enzymatic activity of superoxide dismutase (SOD), catalase (CAT) and glutathione

  20. Promising effects of xanthine oxidase inhibition by allopurinol on autonomic heart regulation estimated by heart rate variability (HRV analysis in rats exposed to hypoxia and hyperoxia.

    Directory of Open Access Journals (Sweden)

    Stanisław Zajączkowski

    Full Text Available It has long been suggested that reactive oxygen species (ROS play a role in oxygen sensing via peripheral chemoreceptors, which would imply their involvement in chemoreflex activation and autonomic regulation of heart rate. We hypothesize that antioxidant affect neurogenic cardiovascular regulation through activation of chemoreflex which results in increased control of sympathetic mechanism regulating heart rhythm. Activity of xanthine oxidase (XO, which is among the major endogenous sources of ROS in the rat has been shown to increase during hypoxia promote oxidative stress. However, the mechanism of how XO inhibition affects neurogenic regulation of heart rhythm is still unclear.The study aimed to evaluate effects of allopurinol-driven inhibition of XO on autonomic heart regulation in rats exposed to hypoxia followed by hyperoxia, using heart rate variability (HRV analysis.16 conscious male Wistar rats (350 g: control-untreated (N = 8 and pretreated with Allopurinol-XO inhibitor (5 mg/kg, followed by 50 mg/kg, administered intraperitoneally (N = 8, were exposed to controlled hypobaric hypoxia (1h in order to activate chemoreflex. The treatment was followed by 1h hyperoxia (chemoreflex suppression. Time-series of 1024 RR-intervals were extracted from 4kHz ECG recording for heart rate variability (HRV analysis in order to calculate the following time-domain parameters: mean RR interval (RRi, SDNN (standard deviation of all normal NN intervals, rMSSD (square root of the mean of the squares of differences between adjacent NN intervals, frequency-domain parameters (FFT method: TSP (total spectral power as well as low and high frequency band powers (LF and HF. At the end of experiment we used rat plasma to evaluate enzymatic activity of XO and markers of oxidative stress: protein carbonyl group and 8-isoprostane concentrations. Enzymatic activity of superoxide dismutase (SOD, catalase (CAT and glutathione peroxidase (GPx were measures in erythrocyte

  1. Attenuated heart rate response is associated with hypocretin deficiency in patients with narcolepsy.

    Science.gov (United States)

    Sorensen, Gertrud Laura; Knudsen, Stine; Petersen, Eva Rosa; Kempfner, Jacob; Gammeltoft, Steen; Sorensen, Helge Bjarup Dissing; Jennum, Poul

    2013-01-01

    Several studies have suggested that hypocretin-1 may influence the cerebral control of the cardiovascular system. We analyzed whether hypocretin-1 deficiency in narcolepsy patients may result in a reduced heart rate response. We analyzed the heart rate response during various sleep stages from a 1-night polysomnography in patients with narcolepsy and healthy controls. The narcolepsy group was subdivided by the presence of +/- cataplexy and +/- hypocretin-1 deficiency. Sleep laboratory studies conducted from 2001-2011. In total 67 narcolepsy patients and 22 control subjects were included in the study. Cataplexy was present in 46 patients and hypocretin-1 deficiency in 38 patients. None. All patients with narcolepsy had a significantly reduced heart rate response associated with arousals and leg movements (P hypocretin-1 deficiency and cataplexy groups compared with patients with normal hypocretin-1 levels (P hypocretin-1 deficiency significantly predicted the heart rate response associated with arousals in both REM and non-REM in a multivariate linear regression. Our results show that autonomic dysfunction is part of the narcoleptic phenotype, and that hypocretin-1 deficiency is the primary predictor of this dysfunction. This finding suggests that the hypocretin system participates in the modulation of cardiovascular function at rest.

  2. Heart rate variability is associated with psychosocial stress in distinct social domains.

    Science.gov (United States)

    Lischke, Alexander; Jacksteit, Robert; Mau-Moeller, Anett; Pahnke, Rike; Hamm, Alfons O; Weippert, Matthias

    2018-03-01

    Psychosocial stress is associated with substantial morbidity and mortality. Accordingly, there is a growing interest in biomarkers that indicate whether individuals show adaptive (i.e., stress-buffering and health-promoting) or maladaptive (i.e., stress-escalating and health-impairing) stress reactions in social contexts. As heart rate variability (HRV) has been suggested to be a biomarker of adaptive behavior during social encounters, it may be possible that inter-individual differences in HRV are associated with inter-individual differences regarding stress in distinct social domains. To test this hypothesis, resting state HRV and psychosocial stress was assessed in 83 healthy community-dwelling individuals (age: 18-35years). HRV was derived from heart rate recordings during spontaneous and instructed breathing to assess the robustness of possible associations between inter-individual differences in HRV and inter-individual differences in psychosocial stress. Psychosocial stress was determined with a self-report questionnaire assessing stress in distinct social domains. A series of categorical and dimensional analyses revealed an association between inter-individual differences in HRV and inter-individual differences in psychosocial stress: Individuals with high HRV reported less stress in social life, but not in family life, work life or everyday life, than individuals with low HRV. On basis of these findings, it may be assumed that individuals with high HRV experience less psychosocial stress than individuals with low HRV. Although such an assumption needs to be corroborated by further findings, it seems to be consistent with previous findings showing that individuals with high HRV suffer less from stress and stress-related disorders than individuals with low HRV. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Anxiety, attention, and decision making: The moderating role of heart rate variability.

    Science.gov (United States)

    Ramírez, Encarnación; Ortega, Ana Raquel; Reyes Del Paso, Gustavo A

    2015-12-01

    The current exploratory research examined whether high frequency heart rate variability (HF-HRV) modulates the association between anxiety and (1) executive attentional control during situations involving neutral stimuli, in which the distractor stimuli are in conflict with the target stimulus, and (2) risk aversion in decision making. Forty-five participants (21 with low and 24 with high trait-anxiety) performed a modified version of the Attention Network Test to measure attentional control, and the Balloon Analog Risk Task to measure risk aversion. HF-HRV was recorded during a rest period before completion of the tasks. Results showed that individuals with high anxiety and low HF-HRV have worse attentional control in the face of conflicting information as well as greater risk aversion, in comparison with individuals with both high anxiety and high HF-HRV or low anxiety (regardless of HF-HRV). HF-HRV was positively associated with attentional control and negatively associated with risk aversion. Furthermore, a strong negative association was observed between attentional control and risk aversion. These results suggest that HF-HRV modulates the influence of anxiety on both attentional control to neutral stimuli, and risk aversion in decision making. Greater HF-HRV appears to fulfill a protective role in highly anxious individuals. The associations observed also suggest that executive control of attention plays a relevant role in decision making. These results support the relevance of the autonomic nervous system in sustained cognition and are in accordance with theories in which vagal-mediated heart rate variability is taken as an indicator of prefrontal cortex inhibitory influences. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT.

    Science.gov (United States)

    Ng, Ming Yen; Karimzad, Yasser; Menezes, Ravi J; Wintersperger, Bernd J; Li, Qin; Forero, Julian; Paul, Narinder S; Nguyen, Elsie T

    2016-10-01

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. • Relaxation music does not reduce heart rate in cardiac CT • Relaxation music does not reduce beta-blocker use in cardiac CT • Relaxation music has no effect on cardiac CT image quality • Low levels of anxiety are present in patients prior to cardiac CT • Patients enjoyed the relaxation music and this results in improved patient experience.

  5. Ivabradine in acute coronary syndromes: Protection beyond heart rate lowering.

    Science.gov (United States)

    Niccoli, Giampaolo; Borovac, Josip Anđelo; Vetrugno, Vincenzo; Camici, Paolo G; Crea, Filippo

    2017-06-01

    Ivabradine is a heart rate reducing agent that exhibits anti-ischemic effects through the inhibition of funny electrical current in the sinus node resulting in heart rate reduction, thus enabling longer diastolic perfusion time, and reduced myocardial oxygen consumption without detrimental changes in arterial blood pressure, coronary vasomotion, and ventricular contractility. The current guideline-based clinical use of Ivabradine is reserved for patients with stable angina pectoris who cannot tolerate or whose symptoms are inadequately controlled with beta blockers. In patients with chronic heart failure and reduced ejection fraction, Ivabradine has demonstrated beneficial effects in improving clinical outcomes when added to conventional therapy. However, the role of Ivabradine in acute coronary syndromes has not been established. Based on the results from some relevant preclinical studies and a limited amount of clinical data that were reported recently, the role of Ivabradine in acute ischemic events warrants further investigation. The aim of this review is to provide an overview of the available literature on the potential role of Ivabradine in the clinical context of acute coronary syndromes. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Impact of pulmonary arterial hypertension and its therapy on indices of heart rate variability.

    Science.gov (United States)

    Can, Mehmet Mustafa; Kaymaz, Cihangir; Pochi, Nartilla; Aktimur, Tugba

    2013-08-01

    To compare heart rate variability (HRV) indices between pulmonary arterial hypertension (PAH) patients and controls, and to investigate whether therapy improves heart rhythm. Thirty-eight patients and 20 controls underwent Holter monitoring. HRV was analyzed before and after PAH therapy. Various time, and frequency domain indices of HRV analysis including standard deviation of all normal-to-normal intervals, standard deviation of mean values for all normal-to-normal intervals over 5 min, and square root of the mean square differences of successive RR intervals were recorded and analyzed before and after 1 year of PAH therapy. Significant differences with regard to diminished physical capacity, impared cardiac output, increased BNP in PAH cohort; HRV indices were diminished compared to controls and no differences between before and after PAH therapy with respect to analysis of HRV. Patients exhibited depressed HRV and therapy failed to improve HRV indices suggesting urgent unmet need for better therapeutic options. Patients with PAH exhibit severely depressed HRV. Surprisingly, PAH specific therapy for 1 year with phosphodiesterase- 5 inhibitor, prostacyclin analogue, endhotelin receptor antagonist, or their combination failed to improve HRV indices suggesting urgent unmet need for better therapeutic options.

  7. Nonlinear Methods to Assess Changes in Heart Rate Variability in Type 2 Diabetic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Bhaskar, Roy, E-mail: imbhaskarall@gmail.com [Indian Institute of Technology (India); University of Connecticut, Farmington, CT (United States); Ghatak, Sobhendu [Indian Institute of Technology (India)

    2013-10-15

    Heart rate variability (HRV) is an important indicator of autonomic modulation of cardiovascular function. Diabetes can alter cardiac autonomic modulation by damaging afferent inputs, thereby increasing the risk of cardiovascular disease. We applied nonlinear analytical methods to identify parameters associated with HRV that are indicative of changes in autonomic modulation of heart function in diabetic patients. We analyzed differences in HRV patterns between diabetic and age-matched healthy control subjects using nonlinear methods. Lagged Poincaré plot, autocorrelation, and detrended fluctuation analysis were applied to analyze HRV in electrocardiography (ECG) recordings. Lagged Poincare plot analysis revealed significant changes in some parameters, suggestive of decreased parasympathetic modulation. The detrended fluctuation exponent derived from long-term fitting was higher than the short-term one in the diabetic population, which was also consistent with decreased parasympathetic input. The autocorrelation function of the deviation of inter-beat intervals exhibited a highly correlated pattern in the diabetic group compared with the control group. The HRV pattern significantly differs between diabetic patients and healthy subjects. All three statistical methods employed in the study may prove useful to detect the onset and extent of autonomic neuropathy in diabetic patients.

  8. Nonlinear Methods to Assess Changes in Heart Rate Variability in Type 2 Diabetic Patients

    International Nuclear Information System (INIS)

    Bhaskar, Roy; Ghatak, Sobhendu

    2013-01-01

    Heart rate variability (HRV) is an important indicator of autonomic modulation of cardiovascular function. Diabetes can alter cardiac autonomic modulation by damaging afferent inputs, thereby increasing the risk of cardiovascular disease. We applied nonlinear analytical methods to identify parameters associated with HRV that are indicative of changes in autonomic modulation of heart function in diabetic patients. We analyzed differences in HRV patterns between diabetic and age-matched healthy control subjects using nonlinear methods. Lagged Poincaré plot, autocorrelation, and detrended fluctuation analysis were applied to analyze HRV in electrocardiography (ECG) recordings. Lagged Poincare plot analysis revealed significant changes in some parameters, suggestive of decreased parasympathetic modulation. The detrended fluctuation exponent derived from long-term fitting was higher than the short-term one in the diabetic population, which was also consistent with decreased parasympathetic input. The autocorrelation function of the deviation of inter-beat intervals exhibited a highly correlated pattern in the diabetic group compared with the control group. The HRV pattern significantly differs between diabetic patients and healthy subjects. All three statistical methods employed in the study may prove useful to detect the onset and extent of autonomic neuropathy in diabetic patients

  9. Features of Heart Rate Variability Capture Regulatory Changes During Kangaroo Care in Preterm Infants.

    Science.gov (United States)

    Kommers, Deedee R; Joshi, Rohan; van Pul, Carola; Atallah, Louis; Feijs, Loe; Oei, Guid; Bambang Oetomo, Sidarto; Andriessen, Peter

    2017-03-01

    To determine whether heart rate variability (HRV) can serve as a surrogate measure to track regulatory changes during kangaroo care, a period of parental coregulation distinct from regulation within the incubator. Nurses annotated the starting and ending times of kangaroo care for 3 months. The pre-kangaroo care, during-kangaroo care, and post-kangaroo care data were retrieved in infants with at least 10 accurately annotated kangaroo care sessions. Eight HRV features (5 in the time domain and 3 in the frequency domain) were used to visually and statistically compare the pre-kangaroo care and during-kangaroo care periods. Two of these features, capturing the percentage of heart rate decelerations and the extent of heart rate decelerations, were newly developed for preterm infants. A total of 191 kangaroo care sessions were investigated in 11 preterm infants. Despite clinically irrelevant changes in vital signs, 6 of the 8 HRV features (SD of normal-to-normal intervals, root mean square of the SD, percentage of consecutive normal-to-normal intervals that differ by >50 ms, SD of heart rate decelerations, high-frequency power, and low-frequency/high-frequency ratio) showed a visible and statistically significant difference (P heart rate decelerations. HRV-based features may be clinically useful for capturing the dynamic changes in autonomic regulation in response to kangaroo care and other changes in environment and state. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Ming Yen [University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada); The University of Hong Kong, Queen Mary Hospital, Department of Diagnostic Radiology, Hong Kong (China); Karimzad, Yasser; Menezes, Ravi J.; Wintersperger, Bernd J.; Li, Qin; Forero, Julian; Paul, Narinder S.; Nguyen, Elsie T. [University of Toronto, Department of Medical Imaging, Toronto General Hospital, Toronto, ON (Canada)

    2016-10-15

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. (orig.)

  11. Randomized controlled trial of relaxation music to reduce heart rate in patients undergoing cardiac CT

    International Nuclear Information System (INIS)

    Ng, Ming Yen; Karimzad, Yasser; Menezes, Ravi J.; Wintersperger, Bernd J.; Li, Qin; Forero, Julian; Paul, Narinder S.; Nguyen, Elsie T.

    2016-01-01

    To evaluate the heart rate lowering effect of relaxation music in patients undergoing coronary CT angiography (CCTA), pulmonary vein CT (PVCT) and coronary calcium score CT (CCS). Patients were randomised to a control group (i.e. standard of care protocol) or to a relaxation music group (ie. standard of care protocol with music). The groups were compared for heart rate, radiation dose, image quality and dose of IV metoprolol. Both groups completed State-Trait Anxiety Inventory anxiety questionnaires to assess patient experience. One hundred and ninety-seven patients were recruited (61.9 % males); mean age 56y (19-86 y); 127 CCTA, 17 PVCT, 53 CCS. No significant difference in heart rate, radiation dose, image quality, metoprolol dose and anxiety scores. 86 % of patients enjoyed the music. 90 % of patients in the music group expressed a strong preference to have music for future examinations. The patient cohort demonstrated low anxiety levels prior to CT. Relaxation music in CCTA, PVCT and CCS does not reduce heart rate or IV metoprolol use. Patients showed low levels of anxiety indicating that anxiolytics may not have a significant role in lowering heart rate. Music can be used in cardiac CT to improve patient experience. (orig.)

  12. Quantitative comparison of entropy analysis of fetal heart rate variability related to the different stages of labor.

    Science.gov (United States)

    Lim, Jongil; Kwon, Ji Young; Song, Juhee; Choi, Hosoon; Shin, Jong Chul; Park, In Yang

    2014-02-01

    The interpretation of the fetal heart rate (FHR) signal considering labor progression may improve perinatal morbidity and mortality. However, there have been few studies that evaluate the fetus in each labor stage quantitatively. To evaluate whether the entropy indices of FHR are different according to labor progression. A retrospective comparative study of FHR recordings in three groups: 280 recordings in the second stage of labor before vaginal delivery, 31 recordings in the first stage of labor before emergency cesarean delivery, and 23 recordings in the pre-labor before elective cesarean delivery. The stored FHR recordings of external cardiotocography during labor. Approximate entropy (ApEn) and sample entropy (SampEn) for the final 2000 RR intervals. The median ApEn and SampEn for the 2000 RR intervals showed the lowest values in the second stage of labor, followed by the emergency cesarean group and the elective cesarean group for all time segments (all PEntropy indices of FHR were significantly different according to labor progression. This result supports the necessity of considering labor progression when developing intrapartum fetal monitoring using the entropy indices of FHR. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. The level of intelligence and heart rate variability in men after myocardial infarction.

    Science.gov (United States)

    Pecyna, M B

    2006-09-01

    Heart rate variability (HRV) reflects periodic changes taking place in heart rhythm, which are controlled by the autonomic nervous system (ANS) and external factors. The aim of the present study was to assess the relationship between HRV and the level of intelligence using the Raven Advanced Matrices Test in 95 men (mean age 41.6 +/-3.7 SD yr) who experienced myocardial infarction during two years preceding the psychophysiological examination. HRV was analyzed from the EEG signal recordings in the time and spectral domains. It was found that post-myocardial infarct men of the higher than average intelligence had significantly increased HRV; the finding was reflected in the analysis of both time and frequency domains. Although both sympathetic and parasympathetic components showed an increase in the frequency domain, the former did disproportionately more, achieving substantial predominance. The results indicate that active mental processes and attitude, linked to a higher intelligence level, might be a beneficial prognostic marker, as is higher HRV, for the overall post-infarction cardiac mortality and for return of such subjects back to normal life. The corollary is that the assessment of IQ in post-infarction patients seems a simple screening method that may help presage the health and social course the patient takes.

  14. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  15. Quantifying the Interactions between Maternal and Fetal Heart Rates by Transfer Entropy.

    Directory of Open Access Journals (Sweden)

    Faezeh Marzbanrad

    Full Text Available Evidence of the short term relationship between maternal and fetal heart rates has been found in previous studies. However there is still limited knowledge about underlying mechanisms and patterns of the coupling throughout gestation. In this study, Transfer Entropy (TE was used to quantify directed interactions between maternal and fetal heart rates at various time delays and gestational ages. Experimental results using maternal and fetal electrocardiograms showed significant coupling for 63 out of 65 fetuses, by statistically validating against surrogate pairs. Analysis of TE showed a decrease in transfer of information from fetus to the mother with gestational age, alongside the maturation of the fetus. On the other hand, maternal to fetal TE was significantly greater in mid (26-31 weeks and late (32-41 weeks gestation compared to early (16-25 weeks gestation (Mann Whitney Wilcoxon (MWW p<0.05. TE further increased from mid to late, for the fetuses with RMSSD of fetal heart rate being larger than 4 msec in the late gestation. This difference was not observed for the fetuses with smaller RMSSD, which could be associated with the quiet sleep state. Delay in the information transfer from mother to fetus significantly decreased (p = 0.03 from mid to late gestation, implying a decrease in fetal response time. These changes occur concomitant with the maturation of the fetal sensory and autonomic nervous systems with advancing gestational age. The effect of maternal respiratory rate derived from maternal ECG was also investigated and no significant relationship was found between breathing rate and TE at any lag. In conclusion, the application of TE with delays revealed detailed information on the fetal-maternal heart rate coupling strength and latency throughout gestation, which could provide novel clinical markers of fetal development and well-being.

  16. Temporal discounting and heart rate reactivity to stress.

    Science.gov (United States)

    Diller, James W; Patros, Connor H G; Prentice, Paula R

    2011-07-01

    Temporal discounting is the reduction of the value of a reinforcer as a function of increasing delay to its presentation. Impulsive individuals discount delayed consequences more rapidly than self-controlled individuals, and impulsivity has been related to substance abuse, gambling, and other problem behaviors. A growing body of literature has identified biological correlates of impulsivity, though little research to date has examined relations between delay discounting and markers of poor health (e.g., cardiovascular reactivity to stress). We evaluated the relation between one aspect of impulsivity, measured using a computerized temporal discounting task, and heart rate reactivity, measured as a change in heart rate from rest during a serial subtraction task. A linear regression showed that individuals who were more reactive to stress responded more impulsively (i.e., discounted delayed reinforcers more rapidly). When results were stratified by gender, the effect was observed for females, but not for males. This finding supports previous research on gender differences in cardiovascular reactivity and suggests that this type of reactivity may be an important correlate of impulsive behavior. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Heart rate variability | Lutfi | Sudan Journal of Medical Sciences

    African Journals Online (AJOL)

    An important outcome of such analysis is heart rate variability (HRV), which is widely accepted to have prognostic significance in patients with cardiovascular diseases especially after acute myocardial infarction. This is because HRV represents one of the most helpful markers of autonomic balance and hence can predict ...

  18. Improved detection of congestive heart failure via probabilistic symbolic pattern recognition and heart rate variability metrics.

    Science.gov (United States)

    Mahajan, Ruhi; Viangteeravat, Teeradache; Akbilgic, Oguz

    2017-12-01

    A timely diagnosis of congestive heart failure (CHF) is crucial to evade a life-threatening event. This paper presents a novel probabilistic symbol pattern recognition (PSPR) approach to detect CHF in subjects from their cardiac interbeat (R-R) intervals. PSPR discretizes each continuous R-R interval time series by mapping them onto an eight-symbol alphabet and then models the pattern transition behavior in the symbolic representation of the series. The PSPR-based analysis of the discretized series from 107 subjects (69 normal and 38 CHF subjects) yielded discernible features to distinguish normal subjects and subjects with CHF. In addition to PSPR features, we also extracted features using the time-domain heart rate variability measures such as average and standard deviation of R-R intervals. An ensemble of bagged decision trees was used to classify two groups resulting in a five-fold cross-validation accuracy, specificity, and sensitivity of 98.1%, 100%, and 94.7%, respectively. However, a 20% holdout validation yielded an accuracy, specificity, and sensitivity of 99.5%, 100%, and 98.57%, respectively. Results from this study suggest that features obtained with the combination of PSPR and long-term heart rate variability measures can be used in developing automated CHF diagnosis tools. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The effects of cigarette smoking on aerobic and anaerobic capacity and heart rate variability among female university students

    Directory of Open Access Journals (Sweden)

    Lee CL

    2013-10-01

    Full Text Available Chia-Lun Lee,1 Wen-Dien Chang21Physical Education Section for General Education, National Sun Yat-sen University, Kaohsiung, Taiwan; 2Department of Sports Medicine, China Medical University, Taichung, TaiwanAim: In this study, the effects of cigarette smoking on maximal aerobic capacity, anaerobic capacity, and heart rate variability among female university students were investigated.Materials and methods: Twelve smokers and 21 nonsmokers participated in this study. All participants performed an intermittent sprint test (IST and a 20 m shuttle run test to measure their anaerobic capacity and maximal aerobic capacity. The IST was comprised of 6 × 10-second sprints with a 60-second active recovery between each sprint. Heart rate variability was recorded while the participants were in a supine position 20 minutes before and 30 minutes after the IST.Results: The total work, peak power, and heart rate of the smokers and nonsmokers did not differ significantly. However, the smokers’ average power declined significantly during sprints 4 to 6 (smokers versus nonsmokers, respectively: 95% confidence interval =6.2–7.2 joule/kg versus 6.8–7.6 joule/kg; P<0.05, and their fatigue index increased (smokers versus nonsmokers, respectively: 35.8% ± 2.3% versus 24.5% ± 1.76%; P<0.05 during the IST. The maximal oxygen uptake of nonsmokers was significantly higher than that of the smokers (P<0.05. The standard deviation of the normal to normal intervals and the root mean square successive difference did not differ significantly between nonsmokers and smokers. However, the nonsmokers exhibited a significantly higher normalized high frequency (HF, and significantly lower normalized low frequency (LF, LF/HF ratio, and natural logarithm of the LF/HF when compared with those of the smokers (P<0.05.Conclusion: Smoking may increase female smokers’ exercise fatigue and decrease their average performance during an IST, while reducing their maximal aerobic

  20. Effects and after-effects of chewing gum on vigilance, heart rate, EEG and mood.

    Science.gov (United States)

    Allen, Andrew P; Jacob, Tim J C; Smith, Andrew P

    2014-06-22

    Research has shown that chewing gum improves attention, although the mechanism for this effect remains unclear. This study investigated the effects and after-effects of chewing gum on vigilance, mood, heart rate and EEG. Participants completed a vigilance task four times; at baseline, with or without chewing gum, and twice post-chewing. EEG alpha and beta power at left frontal and temporal lobes, subjective mood and heart rate were assessed. Chewing gum shortened reaction time and increased the rate of hits, although hits fell during the second post-chewing task. Chewing gum heightened heart rate, but only during chewing. Gum also increased beta power at F7 and T3 immediately post-chewing, but not following the post-chewing tasks. The findings show that chewing gum affects several different indicators of alertness. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Reliability of Heart Rate Variability in Children: Influence of Sex and Body Position During Data Collection.

    Science.gov (United States)

    Silva, Carla Cristiane; Bertollo, Maurizio; Reichert, Felipe Fossati; Boullosa, Daniel Alexandre; Nakamura, Fábio Yuzo

    2017-05-01

    To examine which body position and indices present better reliability of heart rate variability (HRV) measures in children and to compare the HRV analyzed in different body positions between sexes. Twenty eutrophic prepubertal children of each sex participated in the study. The RR intervals were recorded using a portable heart rate monitor twice a day for 7 min in the supine, sitting, and standing positions. The reproducibility was analyzed using the intraclass correlation coefficient (ICC; two way mixed) and within-subject coefficient of variation (CV).Two-way ANOVA with repeated measures was used to compare the sexes. High levels of reproducibility were indicated by higher ICC in the root-mean-square difference of successive normal RR intervals (RMSSD: 0.93 and 0.94) and Poincaré plot of the short-term RR interval variability (SD1: 0.92 and 0.94) parameters for boys and girls, respectively, in the supine position. The ICCs were lower in the sitting and standing positions for all HRV indices. In addition, the girls presented significantly higher values than the boys for SDNN and absolute high frequency (HF; p position. The supine position is the most reproducible for the HRV indices in both sexes, especially the vagal related indices.

  2. The effects of auditory stimulation with music on heart rate variability in healthy women

    Directory of Open Access Journals (Sweden)

    Adriano L. Roque

    2013-07-01

    Full Text Available OBJECTIVES: There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. METHODS: We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21, who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19, who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB. A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB. The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio, low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. RESULTS: The triangular index and the standard deviation of

  3. The effects of auditory stimulation with music on heart rate variability in healthy women.

    Science.gov (United States)

    Roque, Adriano L; Valenti, Vitor E; Guida, Heraldo L; Campos, Mônica F; Knap, André; Vanderlei, Luiz Carlos M; Ferreira, Lucas L; Ferreira, Celso; Abreu, Luiz Carlos de

    2013-07-01

    There are no data in the literature with regard to the acute effects of different styles of music on the geometric indices of heart rate variability. In this study, we evaluated the acute effects of relaxant baroque and excitatory heavy metal music on the geometric indices of heart rate variability in women. We conducted this study in 21 healthy women ranging in age from 18 to 35 years. We excluded persons with previous experience with musical instruments and persons who had an affinity for the song styles. We evaluated two groups: Group 1 (n = 21), who were exposed to relaxant classical baroque musical and excitatory heavy metal auditory stimulation; and Group 2 (n = 19), who were exposed to both styles of music and white noise auditory stimulation. Using earphones, the volunteers were exposed to baroque or heavy metal music for five minutes. After the first music exposure to baroque or heavy metal music, they remained at rest for five minutes; subsequently, they were re-exposed to the opposite music (70-80 dB). A different group of women were exposed to the same music styles plus white noise auditory stimulation (90 dB). The sequence of the songs was randomized for each individual. We analyzed the following indices: triangular index, triangular interpolation of RR intervals and Poincaré plot (standard deviation of instantaneous beat-by-beat variability, standard deviation of the long-term RR interval, standard deviation of instantaneous beat-by-beat variability and standard deviation of the long-term RR interval ratio), low frequency, high frequency, low frequency/high frequency ratio, standard deviation of all the normal RR intervals, root-mean square of differences between the adjacent normal RR intervals and the percentage of adjacent RR intervals with a difference of duration greater than 50 ms. Heart rate variability was recorded at rest for 10 minutes. The triangular index and the standard deviation of the long-term RR interval indices were reduced

  4. Identification of heart rate-associated loci and their effects on cardiac conduction and rhythm disorders

    NARCIS (Netherlands)

    den Hoed, M.A.H.; Eijgelsheim, M.; Esko, T.; Brundel, B.J.; Peal, D.S.; Evans, D.M.; Nolte, I.M.; Segrè, A.V.; Holm, H.; Handsaker, R.E.; Westra, H.J.; Johnson, T.; Isaacs, A.; Yang, L.; Lundby, A.; Zhao, J.H.; Kim, Y.J.; Go, M.J.; Almgren, P.; Bochud, M.; Boucher, G.; Cornelis, M.C.; Gudbjartsson, D.F.; Hadley, D.; van der Harst, P.; Hayward, C.; den Heijer, M.; Igl, W.; Jackson, A.U.; Kutalik, Z.; Luan, J.; Kemp, J.P.; Kristiansson, K.; Ladenvall, C.; Lorentzon, M.; Montasser, M.E.; Njajou, O.T.; O'Reilly, P.F.; Padmanabhan, S.; St Pourcain, B.; Rankinen, T.; Salo, P.; Tanaka, T.; Timpson, N.J.; Vitart, V.; Waite, L.; Wheeler, W.; Zhang, W.; Draisma, H.H.M.; Feitosa, M.F.; Kerr, K.F.; Lind, P.A.; Mihailov, E.; Onland-Moret, N.C.; Song, C.; Weedon, M.N.; Xie, W.; Yengo, L.; Absher, D.; Albert, C.M.; Alonso, A.; Arking, D.E.; de Bakker, P.I.; Balkau, B.; Barlassina, C.; Benaglio, P.; Bis, J.C.; Bouatia-Naji, N.; Brage, S.; Chanock, S.J.; Chines, P.S.; Chung, M.; Darbar, D.; Dina, C.; Dörr, M.; Elliott, P.; Felix, S.B.; Fischer, K.; Fuchsberger, C.; de Geus, E.J.C.; Goyette, P.; Gudnason, V.; Harris, T.B.; Hartikainen, A.L.; Havulinna, A.S.; Heckbert, S.R.; Hicks, A.A.; Hofman, A.; Holewijn, S.; Hoogstra-Berends, F.; Hottenga, J.J.; Jensen, M.K.; Johansson, A.; Junttila, J.; Kääb, S.; Kanon, B.; Ketkar, S.; Khaw, K.T.; Knowles, J.W.; Kooner, A.S.; Kors, J.A.; Kumari, M.; Milani, L.; Laiho, P.; Lakatta, E.G.; Langenberg, C.; Leusink, M.; Liu, Y.; Luben, R.N.; Lunetta, K.L.; Lynch, S.N.; Markus, M.R.; Marques-Vidal, P.; Mateo Leach, I.; McArdle, W.L.; McCarroll, S.A.; Medland, S.E.; Miller, K.A.; Montgomery, G.W.; Morrison, A.C.; Müller-Nurasyid, M.; Navarro, P.; Nelis, M.; O'Connell, J.R.; O'Donnell, C.J.; Ong, K.K.; Newman, A.B.; Peters, A.; Polasek, O.; Pouta, A.; Pramstaller, P.P.; Psaty, B.M.; Rao, D.C.; Ring, S.M.; Rossin, E.J.; Rudan, D.; Sanna, S.; Scott, R.A.; Sehmi, J.S.; Sharp, S.; Shin, J.T.; Singleton, A.B.; Smith, A.V.; Soranzo, N.; Spector, T.D.; Stewart, C.; Stringham, H.M.; Tarasov, K.V.; Uitterlinden, A.G.; Vandenput, L.; Hwang, S.J.; Whitfield, J.B.; Wijmenga, C.; Wild, S.H.; Willemsen, G.; Wilson, J.F.; Witteman, J.C.; Wong, A.; Wong, Q.; Jamshidi, Y.; Zitting, P.; Boer, J.M.; Boomsma, D.I.; Borecki, I.B.; van Duijn, C.M.; Ekelund, U.; Forouhi, N.G.; Froguel, P.; Hingorani, A.D.; Ingelsson, E.; Kivimaki, M.; Kronmal, R.A.; Kuh, D; Lind, L.; Martin, N.G.; Oostra, B.A.; Pedersen, N.L.; Quertermous, T.; Rotter, J.I.; van der Schouw, Y.T.; Verschuren, W.M.; Walker, M.; Albanes, D.; Arnar, D.O.; Assimes, T.L.; Bandinelli, S.; Boehnke, M.; de Boer, R.A.; Bouchard, C.; Caulfield, W.L.; Chambers, J.C.; Curhan, G.; Cusi, D.; Eriksson, J.; Ferrucci, L.; van Gilst, W.H.; Glorioso, N.; de Graaf, J.; Groop, L.; Gyllensten, U.; Hsueh, W.C.; Hu, F.B.; Huikuri, H.V.; Hunter, D.J.; Iribarren, C.; Isomaa, B.; Järvelin, M.R.; Jula, A.; Kähönen, M.; Kiemeney, L.A.; van der Klauw, M.M.; Kooner, J.S.; Kraft, P.; Iacoviello, L.; Lehtimäki, T.; Lokki, M.L.; Mitchell, B.D.; Navis, G.; Nieminen, M.S.; Ohlsson, C.; Poulter, N.R.; Qi, L.; Raitakari, O.T.; Rimm, E.B.; Rioux, J.D.; Rizzi, F.; Rudan, I.; Salomaa, V.; Sever, P.S.; Shields, D.C.; Shuldiner, A.R.; Sinisalo, J.; Stanton, A.V.; Stolk, R.P.; Strachan, D.P.; Tardif, J.C.; Thorsteinsdottir, U.; Tuomilehto, J.; van Veldhuisen, D.J.; Virtamo, J.; Viikari, J.; Vollenweider, P.; Waeber, G.; Widen, E.; Cho, Y.S.; Olsen, J.V.; Visscher, P.M.; Willer, C.J.; Franke, L; Erdmann, J.; Thompson, J.R.; Pfeufer, A.; Sotoodehnia, N.; Newton-Cheh, C.; Ellinor, P.T.; Stricker, B.H.C.; Metspalu, A.; Perola, M.; Beckmann, J.S.; Smith, G.D.; Stefansson, K.; Wareham, N.J.; Munroe, P.B.; Sibon, O.C.M.; Milan, D.J.; Snieder, H.; Samani, N.J.; Loos, R.J.

    2013-01-01

    Elevated resting heart rate is associated with greater risk of cardiovascular disease and mortality. In a 2-stage meta-analysis of genome-wide association studies in up to 181,171 individuals, we identified 14 new loci associated with heart rate and confirmed associations with all 7 previously

  5. Device accurately measures and records low gas-flow rates

    Science.gov (United States)

    Branum, L. W.

    1966-01-01

    Free-floating piston in a vertical column accurately measures and records low gas-flow rates. The system may be calibrated, using an adjustable flow-rate gas supply, a low pressure gage, and a sequence recorder. From the calibration rates, a nomograph may be made for easy reduction. Temperature correction may be added for further accuracy.

  6. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability

    Directory of Open Access Journals (Sweden)

    E.R. Migliaro

    2001-04-01

    Full Text Available In order to assess the relative influence of age, resting heart rate (HR and sedentary life style, heart rate variability (HRV was studied in two different groups. The young group (YG consisted of 9 sedentary subjects aged 15 to 20 years (YG-S and of 9 nonsedentary volunteers (YG-NS also aged 15 to 20. The elderly sedentary group (ESG consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min. R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

  7. Relative influence of age, resting heart rate and sedentary life style in short-term analysis of heart rate variability.

    Science.gov (United States)

    Migliaro, E R; Contreras, P; Bech, S; Etxagibel, A; Castro, M; Ricca, R; Vicente, K

    2001-04-01

    In order to assess the relative influence of age, resting heart rate (HR) and sedentary life style, heart rate variability (HRV) was studied in two different groups. The young group (YG) consisted of 9 sedentary subjects aged 15 to 20 years (YG-S) and of 9 nonsedentary volunteers (YG-NS) also aged 15 to 20. The elderly sedentary group (ESG) consisted of 16 sedentary subjects aged 39 to 82 years. HRV was assessed using a short-term procedure (5 min). R-R variability was calculated in the time-domain by means of the root mean square successive differences. Frequency-domain HRV was evaluated by power spectrum analysis considering high frequency and low frequency bands. In the YG the effort tolerance was ranked in a bicycle stress test. HR was similar for both groups while ESG showed a reduced HRV compared with YG. Within each group, HRV displayed a negative correlation with HR. Although YG-NS had better effort tolerance than YG-S, their HR and HRV were not significantly different. We conclude that HRV is reduced with increasing HR or age, regardless of life style. The results obtained in our short-term study agree with others of longer duration by showing that age and HR are the main determinants of HRV. Our results do not support the idea that changes in HRV are related to regular physical activity.

  8. Facial electromyogram and heart-rate correlates of a paradoxical attitude change to antinuclear war information

    International Nuclear Information System (INIS)

    Vigne, J.J.; Dale, J.A.; Klions, H.L.

    1988-01-01

    The effects of film images versus film descriptions of the effects of nuclear explosions (versus a no-film control) on corrugator muscle tension, heart rate, attitude and mood were investigated. The last 5 min. of the images were associated with more corrugator tension for that condition when compared to the last 5 min. of the description condition. The groups did not differ in heart rate but women in both groups showed an increase in heart rate whereas men in both groups showed a decrease in heart rate. Film groups did not differ in their significant increases in anxiety, hostility, and depression on the Multiple Adjective Affect Checklist. On the pretest there was no significant correlation between scores on Betts' Questionnaire Upon Mental Imagery and scores on Goldenring and Doctor's index of concern for nuclear war. The vivid-image film group showed a decrease in concern for nuclear war when compared to the descriptive film group and the no-film control

  9. The antiarrhythmic effect of vagal stimulation after acute coronary occlusion: Role of the heart rate.

    Science.gov (United States)

    Manati, Waheed; Pineau, Julien; Doñate Puertas, Rosa; Morel, Elodie; Quadiri, Timour; Bui-Xuan, Bernard; Chevalier, Philippe

    2018-01-03

    Strong evidence suggests a causal link between autonomic disturbances and ventricular arrhythmias. However, the mechanisms underlying the antiarrhythmic effect of vagal stimulation are poorly understood. The vagal antiarrhythmic effect might be modulated by a decrease in heart rate. the proximal anterior interventricular artery was occluded in 16 pigs by clamping under general anaesthesia. Group 1: heart rates remained spontaneous (n = 6; 12 occlusions); Group 2: heart rates were fixed at 190 beats per minute (bpm) with atrial electrical stimulation (n = 10; 20 occlusions). Each pig received two occlusions, 30 min apart, one without and one with vagal stimulation (10 Hz, 2 ms, 5-20 mA). The antiarrhythmic effect of vagal activation was defined as the time to the appearance of ventricular fibrillation (VF) after occlusion. In Group 1, vagal stimulation triggered a significant decrease in basal heart rate (132 ± 4 vs. 110 ± 17 bpm, p coronary occlusion (1102 ± 85 vs. 925 ± 41 s, p acute coronary occlusion.

  10. Circadian Disruptions of Heart Rate Variability among Weekly Consecutive-12-hour 2 Shift Workers in the Automobile Factory in Korea.

    Science.gov (United States)

    Son, Mia; Sung, Juhon; Yum, Myunggul; Kong, Jung Ok; Lee, Hye Un; Kim, In A; Kim, Jung Yeon

    2004-05-01

    The objective of this study is to compare the circadian patterns of heart rate variability assessed by 24-hour ambulatory electrocardiographic (ECG) recordings during day shift and night shift among the workers in the 5 days-concecutive- 12-hour shift in an automobile factory in Korea. The study population consisted 300 workers, who were randomly selected among the 8700 total workers in one car factory. To analyse circadian variation, the 24-hour ECG recordings (Marquette) were measured during day shift (08: 00-20: 00 h) and night shift (20: 00-08: 00 h). Analysis was performed for all time and frequency domain measures of HRV. 233 workers completed taking 24-hour ECG recordings. This study shows that the 24 hourcircadian variation mainly follows work/sleep cycle rather than day/night cycle among shift workers. This study also shows that among the night shift, the circadian variation between work and sleep cycle decreased compared to the work/sleep cycle among day shift workers. All time and frequency domain parameters (except LF/HF ratio) show significantly different between work and sleep in the day shift and night shift. These changes in heart rate variability circadian rhythms reflect significant reductions in cardiac parasympathetic activity with the most marked reduction in normal vagal activity among the shift workers. Especially, it suggests the circadian rhytm has blunted among the night workers. The quantification of the circadian variation in HRV can be a surrogates of workers' potential health risk, as well as suggests possible mechanisms through which the shift works compromise workers' health.

  11. Physiological Study on the Relation of Heart Rate Variability in Ageing and Thyroid Hormone Disorder

    Directory of Open Access Journals (Sweden)

    Elsayed A. M. Shokr

    2016-04-01

    Full Text Available The present study aimed to investigate whether cardiac autonomic dysfunction in aging human might be related to an underlying thyroid disturbance. ageing has been associated with hypothyroidism and cardiac autonomic dysfunction. On the basis of body mass index (BMI, 150 patients were grouped into three groups (n = 50 48 years ± 2, 55 years ± 2 and 63 years ± 2. Electrocardiogram was recorded using PowerLab system and the time and frequency domain measures of heart rate variability (HRV were calculated. Fasting blood samples were drawn for measurement of serum thyroid stimulating hormone (TSH, total thyroxin (T4 and total triiodothyronine (T3 concentrations. The levels of TSH, T4 and T3 were not significantly different between the groups. The frequency domain HRV parameter reflecting parasympathetic tone (high-frequency normalized units, HFnu was significantly reduced in aging third groups group. The parameters which reflect sympathetic activation (Heart rate, low-frequency normalized units; LFnu and the LF/HF ratio were significantly increased in the aging group. HFnu was significantly and negatively correlated with age, whereas LFnu and LF/HF ratio were significantly and positively correlated with the above mentioned parameters. No significant relationships were noted between the HRV parameters and the levels of TSH or thyroid hormones. Cardiac autonomic dysfunction in aging human is not linked with underlying thyroid disturbance.

  12. The fall in the rate of death from heart diseases

    International Nuclear Information System (INIS)

    Bemski, G.

    1983-01-01

    A self limiting interaction between heart disease producing factors and genetic factors is postulated. Such an interaction could be responsable for the fall in rate of death from ischemic disease observed in the United States. (Author) [pt

  13. [Heart rate variability and physical exercise. Current status].

    Science.gov (United States)

    Hottenrott, Kuno; Hoos, Olaf; Esperer, Hans Dieter

    2006-09-01

    Heart rate variability (HRV) has long been used in risk stratification for sudden cardiac death and diabetic autonomic neuropathy. In recent years, both time and frequency domain indices of HRV also gained increasing interest in sports and training sciences. In these fields, HRV is currently used for the noninvasive assessment of autonomic changes associated with short-term and long-term endurance exercise training in both leisure sports activity and high-performance training. Furthermore, HRV is being investigated as a diagnostic marker of overreaching and overtraining.A large body of evidence shows that, in healthy subjects and cardiovascular patients of all ages (up to an age of 70 years), regular aerobic training usually results in a significant improvement of overall as well as instantaneous HRV. These changes, which are accompanied by significant reductions in heart rates both at rest and during submaximal exercise, reflect an increase in autonomic efferent activity and a shift in favor of enhanced vagal modulation of the cardiac rhythm. Regular aerobic training of moderate volume and intensity over a minimum period of 3 months seems to be necessary to ensure these effects, which might be associated with a prognostic benefit regarding overall mortality.At present, available data does not allow for final conclusions with respect to the usefulness of traditional HRV indices in assessing an individual's exercise performance and monitoring training load. The discrepant results published so far are due to several factors including insufficient study size and design, and different HRV methods. Large-sized and prospectively designed studies are necessary for clarification. It also remains to be seen, whether the traditional HRV indices prove useful in the diagnosis of overreaching and overtraining. Preliminary results, though promising, need to be confirmed in larger cohorts.A basic problem in HRV analysis is nonstationarity of the heart rate signal, which holds

  14. Heart Rate Variability Density Analysis (Dyx) and Prediction of Long-Term Mortality after Acute Myocardial Infarction

    DEFF Research Database (Denmark)

    Jørgensen, Rikke Mørch; Abildstrøm, Steen Z; Levitan, Jacob

    2016-01-01

    AIMS: The density HRV parameter Dyx is a new heart rate variability (HRV) measure based on multipole analysis of the Poincaré plot obtained from RR interval time series, deriving information from both the time and frequency domain. Preliminary results have suggested that the parameter may provide...... new predictive information on mortality in survivors of acute myocardial infarction (MI). This study compares the prognostic significance of Dyx to that of traditional linear and nonlinear measures of HRV. METHODS AND RESULTS: In the Nordic ICD pilot study, patients with an acute MI were screened...... with 2D echocardiography and 24-hour Holter recordings. The study was designed to assess the power of several HRV measures to predict mortality. Dyx was tested in a subset of 206 consecutive Danish patients with analysable Holter recordings. After a median follow-up of 8.5 years 70 patients had died...

  15. Higher Precision of Heart Rate Compared with VO2 to Predict Exercise Intensity in Endurance-Trained Runners.

    Science.gov (United States)

    Reis, Victor M; den Tillaar, Roland Van; Marques, Mario C

    2011-01-01

    The aim of the present study was to assess the precision of oxygen uptake with heart rate regression during track running in highly-trained runners. Twelve national and international level male long-distance road runners (age 30.7 ± 5.5 yrs, height 1.71 ± 0.04 m and mass 61.2 ± 5.8 kg) with a personal best on the half marathon of 62 min 37 s ± 1 min 22 s participated in the study. Each participant performed, in an all-weather synthetic track five, six min bouts at constant velocity with each bout at an increased running velocity. The starting velocity was 3.33 m·s(-1) with a 0.56 m·s(-1) increase on each subsequent bout. VO2 and heart rate were measured during the runs and blood lactate was assessed immediately after each run. Mean peak VO2 and mean peak heart rate were, respectively, 76.2 ± 9.7 mL·kg(-1)·min(-1) and 181 ± 13 beats·min(-1). The linearity of the regressions between heart rate, running velocity and VO2 were all very high (r > 0.99) with small standard errors of regression (i.e. Sy.x at the velocity associated with the 2 and 4 mmol·L(-1) lactate thresholds). The strong relationships between heart rate, running velocity and VO2 found in this study show that, in highly trained runners, it is possible to have heart rate as an accurate indicator of energy demand and of the running speed. Therefore, in this subject cohort it may be unnecessary to use VO2 to track changes in the subjects' running economy during training periods. Key pointsHeart rate is used in the control of exercise intensity in endurance sports.However, few studies have quantified the precision of its relationship with oxygen uptake in highly trained runners.We evaluated twelve elite half-marathon runners during track running at various intensities and established three regressions: oxygen uptake / heart rate; heart rate / running velocity and oxygen uptake / running velocity.The three regressions presented, respectively, imprecision of 4,2%, 2,75% and 4,5% at the velocity

  16. Variation in heart rate during submaximal exercise: Implications for monitoring training : Implications for monitoring training

    NARCIS (Netherlands)

    Lamberts, R.P.; Lemmink, K.A.P.M.; Durandt, J.J.; Lambert, M.I.

    2004-01-01

    A change in heart rate at a controlled submaximal exercise intensity is used as a marker of training status. However, the standard error of measurement has not been studied systematically, and therefore a change in heart rate, which can be considered relevant, has not been determined. Forty-four

  17. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    Science.gov (United States)

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  18. Atenolol Is Associated with Lower Day of Surgery Heart Rate as compared to Long and Short-acting Metoprolol

    Science.gov (United States)

    Schonberger, Robert B.; Brandt, Cynthia; Feinleib, Jessica; Dai, Feng; Burg, Matthew M.

    2012-01-01

    Objectives We analyzed the association between outpatient beta-blocker type and day-of-surgery heart rate in ambulatory surgical patients. We further investigated whether differences in day of surgery heart rate between atenolol and metoprolol could be explained by once-daily versus twice-daily dosing regimens. Design Retrospective observational study. Setting VA Hospital Participants Ambulatory surgical patients on chronic atenolol or metoprolol. Interventions None. Measurements and Main Results Using a propensity-score matched cohort, we compared day of surgery heart rates of patients prescribed atenolol versus metoprolol. We then differentiated between once-daily and twice-daily metoprolol formulations and compared day of surgery heart rates within a general linear model. Day of surgery heart rates in patients prescribed atenolol vs. any metoprolol formulation were slower by a mean of 5.1 beats/min (66.6 vs. 71.7; 95% CI of difference 1.9 to 8.3, p=0.002), a difference that was not observed in preoperative primary care visits. The general linear model demonstrated that patients prescribed atenolol (typically QD dosing) had a mean day of surgery heart rate 5.6 beats/min lower compared to patients prescribed once-daily metoprolol succinate (68.9 vs. 74.5; 95% CI of difference: −8.6 to −2.6, p<0.001) and 3.8 beats/minute lower compared to patients prescribed twice-daily metoprolol tartrate (68.9 vs. 72.7; 95% CI of difference: −6.1 to −1.6, p<0.001). Day of surgery heart rates were similar between different formulations of metoprolol (95% CI of difference: −1.0 to +4.6, p=0.22). Conclusions Atenolol is associated with lower day of surgery heart rate vs. metoprolol. The heart rate difference is specific to the day of surgery and is not explained by once-daily versus twice-daily dosing regimens. PMID:22889605

  19. Longitudinal Associations of Leptin and Adiponectin with Heart Rate Variability in Children

    Directory of Open Access Journals (Sweden)

    Roos Van De Wielle

    2017-07-01

    Full Text Available For early prevention of cardiovascular disease, early detection and risk factor insights are necessary. The autonomic balance reflects cardiovascular risk and can be measured by heart rate variability (HRV. Therefore, our purpose is to examine associations between HRV and the energy-related biomarkers leptin and adiponectin in children. Participants of this study were Belgian children recruited for the longitudinal ChiBS study (year 2010–2012. HRV was measured and fasting blood samples were taken in 249 children at baseline (4.4–11.0 y and 223 children at follow-up (6.7–12.2 y. Cross-sectional and longitudinal linear regression analyses were separated by sex and adjusted for age, socio-economic status, body fat%, negative emotions, puberty, and mean heart rate. Leptin was a negative cross-sectional and longitudinal predictor of parasympathetic activity in boys; while leptin in girls was cross-sectionally associated with higher LF and LF/HF suggesting sympathetic predominance. Adiponectin was a negative cross-sectional and longitudinal predictor of parasympathetic activity in boys; but when adjusting for mean heart rate, this effect disappeared and adiponectin was a positive cross-sectional and longitudinal predictor of parasympathetic activity in girls. These results stress the importance of considering sex differences and adjustment for heart rate in testing HRV predictors. Leptin seemed disadvantageous for the autonomic balance, while adiponectin seemed advantageous for the autonomic balance in girls only. More research is needed to see whether leptin and adiponectin are interesting in cardiovascular screening/prevention or in determining the cardiovascular gain during weight loss follow-up.

  20. The heart rate response to nintendo wii boxing in young adults.

    Science.gov (United States)

    Bosch, Pamela R; Poloni, Joseph; Thornton, Andrew; Lynskey, James V

    2012-06-01

    To determine if 30 minutes of Nintendo Wii Sports boxing provides cardiorespiratory benefits and contributes to the daily exercise recommendations for healthy young adults. Twenty healthy 23- to 27-year-olds participated in two sessions to measure maximum heart rate (HR(max)) via a treadmill test and heart rate (HR) response to 30 minutes of Wii Sports boxing. Heart rate in beats per minute (bpm) was measured continuously, and exercise intensity during each minute of play was stratified as a percentage of HR(max). Mixed designs analysis of variance (ANOVA) and Pearson product moment correlations were used to analyze the data. Mean (SD) HR response to boxing was 143 (15) bpm or 77.5% (10.0%) of HR(max). The mean HR response for experienced participants was significantly lower than inexperienced participants, P = .007. The ANOVA revealed a significant interaction between experience and time spent at various intensities, P = .009. Experienced participants spent more time in light to vigorous intensities, inexperienced participants in moderate to very hard intensities. Fitness was not correlated with mean HR response to boxing, P = .49. Thirty minutes of Nintendo Wii Sports boxing provides a moderate to vigorous aerobic response in healthy young adults and can contribute to daily recommendations for physical activity.

  1. Association between resting heart rate and N-terminal pro-brain natriuretic peptide in a community-based population study in Beijing

    Directory of Open Access Journals (Sweden)

    Cao R

    2014-12-01

    Full Text Available Ruihua Cao, Yongyi Bai, Ruyi Xu, Ping Ye Department of Geriatric Cardiology, Chinese PLA General Hospital, Beijing, People’s Republic of China Background: N-terminal pro-brain natriuretic peptide (NT-proBNP is associated with an increased risk of cardiac insufficiency, which possibly leads to heart failure. However, the relationship between resting heart rate and NT-proBNP is unclear.Objective: This study focuses on this relativity between resting heart rate and plasma NT-proBNP levels in a surveyed community-based population.Methods: We evaluated the relativity between resting heart rate and plasma levels of NT-proBNP in 1,567 participants (mean age 61.0 years, range 21–96 years from a community-based population in Beijing, People’s Republic of China.Results: In patients with high resting heart rate (≥75 beats/min, NT-proBNP was higher than in those having low resting heart rate (<75 beats/min. In multiple linear stepwise regression analysis, plasma NT-proBNP was associated with resting heart rate (partial correlation coefficient, 0.82; 95% confidence interval, 0.18–1.51; P=0.011. A subsequent subgroup analysis revealed that the association between resting heart rate and plasma NT-proBNP was strengthened in subjects over 60 years old (partial correlation coefficient 1.28; 95% confidence interval, 0.49–2.36; P=0.031; while the relativity between resting heart rate and plasma NT-proBNP was not emerged in the younger subgroup (<60 years old.Conclusions: Resting heart rate was associated with plasma NT-proBNP in the elderly, which indicated a relationship between resting heart rate and cardiac function damage. Keywords: resting heart rate, N-terminal pro-brain natriuretic peptide, epidemiology, cardiac function, relationship

  2. Effects of Orthostatism and Hemodialysis on Mean Heart Period and Fractal Heart Rate Properties of Chronic Renal Failure Patients.

    Science.gov (United States)

    Echeverría, Juan C; Infante, Oscar; Pérez-Grovas, Héctor; González, Hortensia; José, Marco V; Lerma, Claudia

    2017-11-01

    The aim of this work was to evaluate the short-term fractal index (α 1 ) of heart rate variability (HRV) in chronic renal failure (CRF) patients by identifying the effects of orthostatism and hemodialysis (HD), and by evaluating the correlation between α 1 and the mean RR interval from sinus beats (meanNN). HRV time series were derived from ECG data of 19 CRF patients and 20 age-matched healthy subjects obtained at supine and orthostatic positions (lasting 5 min each). Data from CRF patients were collected before and after HD. α 1 was calculated from each time series and compared by analysis of variance. Pearson's correlations between meanNN and α 1 were calculated using the data from both positions by considering three groups: healthy subjects, CRF before HD and CRF after HD. At supine position, α 1 of CRF patients after HD (1.17 ± 0.30) was larger (P renal disease condition in itself. In conclusion, as in healthy subjects, α 1 of CRF patients correlates with meanNN after HD (indicating a more irregular-like HRV behavior at slower heart rates). This suggests that CRF patients with stable blood pressure preserve a regulatory adaptability despite a shifted setting point of the heart period (i.e., higher heart rate) in comparison with healthy subjects. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  3. Heart Rate Variability Responses of Individuals With and Without Saline-Induced Obstructive Sleep Apnea.

    Science.gov (United States)

    Vena, Daniel; Bradley, T Douglas; Millar, Philip J; Floras, John S; Rubianto, Jonathan; Gavrilovic, Bojan; Perger, Elisa; Yadollahi, Azadeh

    2018-03-30

    Postoperative development of obstructive sleep apnea (OSA) has been attributed to the fluid overloaded state of patients during the postoperative period. In this context, alterations in cardiac autonomic regulation caused by OSA may explain the increased postoperative risk for adverse cardiovascular events. This study tests the hypothesis that individuals with fluid overload-induced OSA will experience autonomic dysregulation, compared to those without fluid overload-induced OSA. Twenty-one normotensive, nonobese (mean body mass index 24.5 kg/m2) males (mean age 37 years) underwent a sleep study. Participants were randomly assigned to infusion with saline during sleep either at the minimum rate (control) or as a bolus of 22 mL/kg body weight (intervention). Participants were blinded to the intervention and crossed over to the other study arm after 1 week. Measures of heart rate variability were calculated from electrocardiography recordings presaline and postsaline infusion in the intervention arm. Heart rate variability measures computed were: standard deviation of the RR interval; root mean square of successive differences; low-frequency, high-frequency, and total power; and the ratio of low-frequency to high-frequency power. Although presaline infusion values were similar, postsaline infusion values of the standard deviation of the RR interval and high-frequency power were lower in the group whose apnea-hypopnea index increased in response to saline infusion, compared to the group whose apnea-hypopnea index did not increase in response to saline infusion ( P variability, consistent with vagal withdrawal. Future work should explore autonomic dysregulation in the postoperative period and its association with adverse events. Copyright © 2018 American Academy of Sleep Medicine. All rights reserved.

  4. Mortality by Heart Failure and Ischemic Heart Disease in Brazil from 1996 to 2011

    International Nuclear Information System (INIS)

    Gaui, Eduardo Nagib; Oliveira, Gláucia Maria Moraes de; Klein, Carlos Henrique

    2014-01-01

    Circulatory system diseases are the first cause of death in Brazil. To analyze the evolution of mortality caused by heart failure, by ischemic heart diseases and by ill-defined causes, as well as their possible relations, in Brazil and in the geoeconomic regions of the country (North, Northeast, Center-West, South and Southeast), from 1996 to 2011. Data were obtained from DATASUS and death declaration records with codes I20 and I24 for acute ischemic diseases, I25 for chronic ischemic diseases, and I50 for heart failure, and codes in chapter XIII for ill-defined causes, according to geoeconomic regions of Brazil, from 1996 to 2011. Mortality rates due to heart failure declined in Brazil and its regions, except for the North and the Northeast. Mortality rates due to acute ischemic heart diseases increased in the North and Northeast regions, especially from 2005 on; they remained stable in the Center-West region; and decreased in the South and in the Southeast. Mortality due to chronic ischemic heart diseases decreased in Brazil and in the Center-West, South and Southeast regions, and had little variation in the North and in the Northeast. The highest mortality rates due to ill-defined causes occurred in the Northeast until 2005. Mortality due to heart failure is decreasing in Brazil and in all of its geoeconomic regions. The temporal evolution of mortality caused by ischemic heart diseases was similar to that of heart failure. The decreasing number of deaths due to ill-defined causes may represent the improvement in the quality of information about mortality in Brazil. The evolution of acute ischemic heart diseases ranged according to regions, being possibly confused with the differential evolution of ill-defined causes

  5. Mortality by Heart Failure and Ischemic Heart Disease in Brazil from 1996 to 2011

    Directory of Open Access Journals (Sweden)

    Eduardo Nagib Gaui

    2014-06-01

    Full Text Available Background: Circulatory system diseases are the first cause of death in Brazil. Objective: To analyze the evolution of mortality caused by heart failure, by ischemic heart diseases and by ill-defined causes, as well as their possible relations, in Brazil and in the geoeconomic regions of the country (North, Northeast, Center-West, South and Southeast, from 1996 to 2011. Methods: Data were obtained from DATASUS and death declaration records with codes I20 and I24 for acute ischemic diseases, I25 for chronic ischemic diseases, and I50 for heart failure, and codes in chapter XIII for ill-defined causes, according to geoeconomic regions of Brazil, from 1996 to 2011. Results: Mortality rates due to heart failure declined in Brazil and its regions, except for the North and the Northeast. Mortality rates due to acute ischemic heart diseases increased in the North and Northeast regions, especially from 2005 on; they remained stable in the Center-West region; and decreased in the South and in the Southeast. Mortality due to chronic ischemic heart diseases decreased in Brazil and in the Center-West, South and Southeast regions, and had little variation in the North and in the Northeast. The highest mortality rates due to ill-defined causes occurred in the Northeast until 2005. Conclusions: Mortality due to heart failure is decreasing in Brazil and in all of its geoeconomic regions. The temporal evolution of mortality caused by ischemic heart diseases was similar to that of heart failure. The decreasing number of deaths due to ill-defined causes may represent the improvement in the quality of information about mortality in Brazil. The evolution of acute ischemic heart diseases ranged according to regions, being possibly confused with the differential evolution of ill-defined causes.

  6. Mortality by Heart Failure and Ischemic Heart Disease in Brazil from 1996 to 2011

    Energy Technology Data Exchange (ETDEWEB)

    Gaui, Eduardo Nagib, E-mail: engaui@cardiol.br; Oliveira, Gláucia Maria Moraes de [Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ (Brazil); Klein, Carlos Henrique [Escola Nacional de Saúde Pública Sérgio Arouca da Fundação Oswaldo Cruz, Rio de Janeiro, RJ (Brazil)

    2014-06-15

    Circulatory system diseases are the first cause of death in Brazil. To analyze the evolution of mortality caused by heart failure, by ischemic heart diseases and by ill-defined causes, as well as their possible relations, in Brazil and in the geoeconomic regions of the country (North, Northeast, Center-West, South and Southeast), from 1996 to 2011. Data were obtained from DATASUS and death declaration records with codes I20 and I24 for acute ischemic diseases, I25 for chronic ischemic diseases, and I50 for heart failure, and codes in chapter XIII for ill-defined causes, according to geoeconomic regions of Brazil, from 1996 to 2011. Mortality rates due to heart failure declined in Brazil and its regions, except for the North and the Northeast. Mortality rates due to acute ischemic heart diseases increased in the North and Northeast regions, especially from 2005 on; they remained stable in the Center-West region; and decreased in the South and in the Southeast. Mortality due to chronic ischemic heart diseases decreased in Brazil and in the Center-West, South and Southeast regions, and had little variation in the North and in the Northeast. The highest mortality rates due to ill-defined causes occurred in the Northeast until 2005. Mortality due to heart failure is decreasing in Brazil and in all of its geoeconomic regions. The temporal evolution of mortality caused by ischemic heart diseases was similar to that of heart failure. The decreasing number of deaths due to ill-defined causes may represent the improvement in the quality of information about mortality in Brazil. The evolution of acute ischemic heart diseases ranged according to regions, being possibly confused with the differential evolution of ill-defined causes.

  7. Job strain and resting heart rate: a cross-sectional study in a Swedish random working sample

    Directory of Open Access Journals (Sweden)

    Peter Eriksson

    2016-03-01

    Full Text Available Abstract Background Numerous studies have reported an association between stressing work conditions and cardiovascular disease. However, more evidence is needed, and the etiological mechanisms are unknown. Elevated resting heart rate has emerged as a possible risk factor for cardiovascular disease, but little is known about the relation to work-related stress. This study therefore investigated the association between job strain, job control, and job demands and resting heart rate. Methods We conducted a cross-sectional survey of randomly selected men and women in Västra Götalandsregionen, Sweden (West county of Sweden (n = 1552. Information about job strain, job demands, job control, heart rate and covariates was collected during the period 2001–2004 as part of the INTERGENE/ADONIX research project. Six different linear regression models were used with adjustments for gender, age, BMI, smoking, education, and physical activity in the fully adjusted model. Job strain was operationalized as the log-transformed ratio of job demands over job control in the statistical analyses. Results No associations were seen between resting heart rate and job demands. Job strain was associated with elevated resting heart rate in the unadjusted model (linear regression coefficient 1.26, 95 % CI 0.14 to 2.38, but not in any of the extended models. Low job control was associated with elevated resting heart rate after adjustments for gender, age, BMI, and smoking (linear regression coefficient −0.18, 95 % CI −0.30 to −0.02. However, there were no significant associations in the fully adjusted model. Conclusions Low job control and job strain, but not job demands, were associated with elevated resting heart rate. However, the observed associations were modest and may be explained by confounding effects.

  8. Non-stationarities significantly distort short-term spectral, symbolic and entropy heart rate variability indices

    International Nuclear Information System (INIS)

    Magagnin, Valentina; Bassani, Tito; Bari, Vlasta; Turiel, Maurizio; Porta, Alberto; Maestri, Roberto; Pinna, Gian Domenico

    2011-01-01

    The autonomic regulation is non-invasively estimated from heart rate variability (HRV). Many methods utilized to assess autonomic regulation require stationarity of HRV recordings. However, non-stationarities are frequently present even during well-controlled experiments, thus potentially biasing HRV indices. The aim of our study is to quantify the potential bias of spectral, symbolic and entropy HRV indices due to non-stationarities. We analyzed HRV series recorded in healthy subjects during uncontrolled daily life activities typical of 24 h Holter recordings and during predetermined levels of robotic-assisted treadmill-based physical exercise. A stationarity test checking the stability of the mean and variance over short HRV series (about 300 cardiac beats) was utilized to distinguish stationary periods from non-stationary ones. Spectral, symbolic and entropy indices evaluated solely over stationary periods were contrasted with those derived from all the HRV segments. When indices were calculated solely over stationary series, we found that (i) during both uncontrolled daily life activities and controlled physical exercise, the entropy-based complexity indices were significantly larger; (ii) during uncontrolled daily life activities, the spectral and symbolic indices linked to sympathetic modulation were significantly smaller and those associated with vagal modulation were significantly larger; (iii) while during uncontrolled daily life activities, the variance of spectral, symbolic and entropy rate indices was significantly larger, during controlled physical exercise, it was smaller. The study suggests that non-stationarities increase the likelihood to overestimate the contribution of sympathetic control and affect the power of statistical tests utilized to discriminate conditions and/or groups

  9. The relationship between the parameters (Heart rate, Ejection fraction and BMI) and the maximum enhancement time of ascending aorta

    International Nuclear Information System (INIS)

    Jang, Young Ill; June, Woon Kwan; Dong, Kyeong Rae

    2007-01-01

    In this study, Bolus Tracking method was used to investigate the parameters affecting the time when contrast media is reached at 100 HU (T 100 ) and studied the relationship between parameters and T 100 because the time which is reached at aorta through antecubital vein after injecting contrast media is different from person to person. Using 64 MDCT, Cadiac CT, the data were obtained from 100 patients (male: 50, female: 50, age distribution: 21⁓81, average age: 57.5) during July and September, 2007 by injecting the contrast media at 4 ml∙sec -1 through their antecubital vein except having difficulties in stopping their breath and having arrhythmia. Using Somatom Sensation Cardiac 64 Siemens, patients’ height and weight were measured to know their mean Heart rate and BMI. Ejection Fraction was measured using Argus Program at Wizard Workstation. Variances of each parameter were analyzed depending on T 100 ’s variation with multiple comparison and the correlation of Heart rate, Ejection Fraction and BMI were analyzed, as well. According to T 100 ’s variation caused by Heart rate, Ejection Fraction and BMI variations, the higher patients’ Heart Rate and Ejection Fraction were, the faster T 100 ’s variations caused by Heart Rate and Ejection Fraction were. The lower their Heart Rate and Ejection Fraction were, the slower T 100 ’s variations were, but T 100 ’s variations caused by BMI were not affected. In the correlation between T 100 and parameters, Heart Rate (p⁄0.01) and Ejection Fraction (p⁄0.05) were significant, but BMI was not significant (p¤0.05). In the Heart Rate, Ejection Fraction and BMI depending on Fast (17 sec and less), Medium (18⁓21 sec), Slow (22 sec and over) Heart Rate was significant at Fast and Slow and Ejection Fraction was significant Fast and Slow as well as Medium and Slow (p⁄0.05), but BMI was not statistically significant. Of the parameters (Heart Rate, Ejection Fraction and BMI) which would affect T 100 , Heart

  10. Effects of omega-3 fatty acids on resting heart rate, heart rate recovery after exercise, and heart rate variability in men with healed myocardial infarctions and depressed ejection fractions.

    Science.gov (United States)

    O'Keefe, James H; Abuissa, Hussam; Sastre, Antonio; Steinhaus, David M; Harris, William S

    2006-04-15

    We explored possible mechanisms by which recommended intakes of omega-3 fatty acids may decrease the risk for sudden cardiac death in patients with documented coronary heart disease. The cardioprotective effects of omega-3 fatty acids have been documented in epidemiologic and randomized controlled trials. These fatty acids are presumed to decrease susceptibility to fatal arrhythmias, but whether this is mediated by classic risk factors or direct cardiac mechanisms is not known. Eighteen white men with a history of myocardial infarction and ejection fractions <40% were randomized to placebo or omega-3 fatty acids (585 mg of docosahexaenoic acid and 225 mg of eicosapentaenoic acid) for two 4-month periods in a crossover design. At the end of each period, heart rate (HR), HR variability, and rate of HR recovery after exercise were determined, as were effects on arterial compliance, blood pressure, cardiac function, and fasting serum levels of lipids and inflammatory markers. Omega-3 fatty acids decreased HR at rest from 73 +/- 13 to 68 +/- 13 beats/min (p <0.0001) and improved 1-minute HR recovery after exercise (-27 +/- 10 to -32 +/- 12 beats/min, p <0.01). HR variability in the high-frequency band increased (p <0.02), but no change was noted in overall HR variability. There were no significant effects on blood pressure, arterial compliance, lipids, or inflammatory markers. These changes are consistent with an increase in vagal activity and may in part explain the observed decrease in risk for sudden cardiac death seen with omega-3 fatty acid supplementation.

  11. Changes in heart rate variability and QT variability during the first trimester of pregnancy.

    Science.gov (United States)

    Carpenter, R E; D'Silva, L A; Emery, S J; Uzun, O; Rassi, D; Lewis, M J

    2015-03-01

    The risk of new-onset arrhythmia during pregnancy is high, presumably relating to changes in both haemodynamic and cardiac autonomic function. The ability to non-invasively assess an individual's risk of developing arrhythmia during pregnancy would therefore be clinically significant. We aimed to quantify electrocardiographic temporal characteristics during the first trimester of pregnancy and to compare these with non-pregnant controls. Ninety-nine pregnant women and sixty-three non-pregnant women underwent non-invasive cardiovascular and haemodynamic assessment during a protocol consisting of various physiological states (postural manoeurvres, light exercise and metronomic breathing). Variables measured included stroke volume, cardiac output, heart rate, heart rate variability, QT and QT variability and QTVI (a measure of the variability of QT relative to that of RR). Heart rate (p pregnancy only during the supine position (p pregnancy in all physiological states (p pregnancy in all states (p pregnancy is associated with substantial changes in heart rate variability, reflecting a reduction in parasympathetic tone and an increase in sympathetic activity. QTVI shifted to a less favourable value, reflecting a greater than normal amount of QT variability. QTVI appears to be a useful method for quantifying changes in QT variability relative to RR (or heart rate) variability, being sensitive not only to physiological state but also to gestational age. We support the use of non-invasive markers of cardiac electrical variability to evaluate the risk of arrhythmic events in pregnancy, and we recommend the use of multiple physiological states during the assessment protocol.

  12. Non-contact Real-time heart rate measurements based on high speed circuit technology research

    Science.gov (United States)

    Wu, Jizhe; Liu, Xiaohua; Kong, Lingqin; Shi, Cong; Liu, Ming; Hui, Mei; Dong, Liquan; Zhao, Yuejin

    2015-08-01

    In recent years, morbidity and mortality of the cardiovascular or cerebrovascular disease, which threaten human health greatly, increased year by year. Heart rate is an important index of these diseases. To address this status, the paper puts forward a kind of simple structure, easy operation, suitable for large populations of daily monitoring non-contact heart rate measurement. In the method we use imaging equipment video sensitive areas. The changes of light intensity reflected through the image grayscale average. The light change is caused by changes in blood volume. We video the people face which include the sensitive areas (ROI), and use high-speed processing circuit to save the video as AVI format into memory. After processing the whole video of a period of time, we draw curve of each color channel with frame number as horizontal axis. Then get heart rate from the curve. We use independent component analysis (ICA) to restrain noise of sports interference, realized the accurate extraction of heart rate signal under the motion state. We design an algorithm, based on high-speed processing circuit, for face recognition and tracking to automatically get face region. We do grayscale average processing to the recognized image, get RGB three grayscale curves, and extract a clearer pulse wave curves through independent component analysis, and then we get the heart rate under the motion state. At last, by means of compare our system with Fingertip Pulse Oximeter, result show the system can realize a more accurate measurement, the error is less than 3 pats per minute.

  13. Effects of Interval Training Programme on Resting Heart Rate in ...

    African Journals Online (AJOL)

    DATONYE ALASIA

    Subjects with Hypertension: A Randomized Controlled Trial. Type of Article: Original ... Resting Heart Rate in Subjects with Hypertension — Lamina S. et al investigate the effect of interval .... changes in VO max) of interest. In the t-test. 2.

  14. Modest weight loss in moderately overweight postmenopausal women improves heart rate variability

    DEFF Research Database (Denmark)

    Mouridsen, Mette Rauhe; Bendsen, Nathalie Tommerup; Astrup, Arne

    2013-01-01

    Purpose: To evaluate the effects of weight loss on heart rate (HR) and heart rate variability (HRV) parameters in overweight postmenopausal women. Design and Methods: Forty-nine overweight postmenopausal women with an average body mass index of 28.8 1.9 kg/m2 underwent a 12-week dietary weight......-to-normal intervals for each 5-min period (SDNNindex). Baseline body fat mass (FM%) and changes in body composition was determined by dual X-ray absorptiometry. Before and after the weight-loss period, total abdominal fat, intra-abdominal fat (IAAT), and subcutaneous abdominal fat (SCAT) were measured by single...

  15. Decreased heart rate variability in surgeons during night shifts

    DEFF Research Database (Denmark)

    Amirian, Ilda; Toftegård Andersen, Lærke; Rosenberg, Jacob

    2014-01-01

    BACKGROUND: Heart rate variability (HRV) has been used as a measure of stress and mental strain in surgeons. Low HRV has been associated with death and increased risk of cardiac events in the general population. The aim of this study was to clarify the effect of a 17-hour night shift on surgeons'...

  16. Anti-Hyperlipidaemic and Heart Rate Lowering Effects of Aqueous ...

    African Journals Online (AJOL)

    The anti-hyperlipidaemic and heart rate lowering potential of aqueous leaf extract of Viscum album (mistletoe) in hypercholesterolaemic rats was investigated in this study. The lethality studies showed that the aqueous extract of the plant had an LD50 value of 452.20mg/kg by intraperitoneal route. There were significant ...

  17. Importance of heart rate during exercise for response to cardiac resynchronization therapy.

    Science.gov (United States)

    Maass, Alexander H; Buck, Sandra; Nieuwland, Wybe; Brügemann, Johan; van Veldhuisen, Dirk J; Van Gelder, Isabelle C

    2009-07-01

    Cardiac resynchronization therapy (CRT) is an established therapy for patients with severe heart failure and mechanical dyssynchrony. Response is only achieved in 60-70% of patients. To study exercise-related factors predicting response to CRT. We retrospectively examined consecutive patients in whom a CRT device was implanted. All underwent cardiopulmonary exercise testing prior to implantation and after 6 months. The occurrence of chronotropic incompetence and heart rates exceeding the upper rate of the device, thereby compromising biventricular stimulation, was studied. Response was defined as a decrease in LVESV of 10% or more after 6 months. We included 144 patients. After 6 months 86 (60%) patients were responders. Peak VO2 significantly increased in responders. Chronotropic incompetence was more frequently seen in nonresponders (21 [36%] vs 9 [10%], P = 0.03), mostly in patients in SR. At moderate exercise, defined as 25% of the maximal exercise tolerance, that is, comparable to daily life exercise, nonresponders more frequently went above the upper rate of the device (13 [22%] vs 2 [3%], P exercise (OR 15.8 [3.3-76.5], P = 0.001) and nonischemic cardiomyopathy (OR 2.4 [1.0-5.7], P = 0.04) as predictive for response. Heart rate exceeding the upper rate during moderate exercise is an independent predictor for nonresponse to CRT in patients with AF, whereas chronotropic incompetence is a predictor for patients in SR.

  18. Effect of mental challenge induced by movie clips on action potential duration in normal human subjects independent of heart rate.

    Science.gov (United States)

    Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O'Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter

    2014-06-01

    Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Activation recovery intervals measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady-state pacing, whilst subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Hemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (P=0.001). APD decreased during the stressful parts of the film clip, for example, for global right ventricular activation recovery interval at end of film clip 193.8 ms (SD, 14) versus 198.0 ms (SD, 13) during the matched breathing control (end film left ventricle 199.8 ms [SD, 16] versus control 201.6 ms [SD, 15]; P=0.004). Respiration rate increased during the stressful part of the film clip (by 2 breaths per minute) and was well matched in the respective control period without any hemodynamic or activation recovery interval changes. Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular APD in conscious humans. The effect of mental challenge on APD was not secondary to emotionally induced altered respiration or heart rate. © 2014 American Heart Association, Inc.

  19. Risk-adjustment models for heart failure patients' 30-day mortality and readmission rates: the incremental value of clinical data abstracted from medical charts beyond hospital discharge record.

    Science.gov (United States)

    Lenzi, Jacopo; Avaldi, Vera Maria; Hernandez-Boussard, Tina; Descovich, Carlo; Castaldini, Ilaria; Urbinati, Stefano; Di Pasquale, Giuseppe; Rucci, Paola; Fantini, Maria Pia

    2016-09-06

    Hospital discharge records (HDRs) are routinely used to assess outcomes of care and to compare hospital performance for heart failure. The advantages of using clinical data from medical charts to improve risk-adjustment models remain controversial. The aim of the present study was to evaluate the additional contribution of clinical variables to HDR-based 30-day mortality and readmission models in patients with heart failure. This retrospective observational study included all patients residing in the Local Healthcare Authority of Bologna (about 1 million inhabitants) who were discharged in 2012 from one of three hospitals in the area with a diagnosis of heart failure. For each study outcome, we compared the discrimination of the two risk-adjustment models (i.e., HDR-only model and HDR-clinical model) through the area under the ROC curve (AUC). A total of 1145 and 1025 patients were included in the mortality and readmission analyses, respectively. Adding clinical data significantly improved the discrimination of the mortality model (AUC = 0.84 vs. 0.73, p < 0.001), but not the discrimination of the readmission model (AUC = 0.65 vs. 0.63, p = 0.08). We identified clinical variables that significantly improved the discrimination of the HDR-only model for 30-day mortality following heart failure. By contrast, clinical variables made little contribution to the discrimination of the HDR-only model for 30-day readmission.

  20. Attachment Status Affects Heart Rate Responses to Experimental Ostracism in Inpatients with Depression.

    Directory of Open Access Journals (Sweden)

    Jannika De Rubeis

    Full Text Available Depression is assumed to be both a risk factor for rejection and a result of it, and as such constitutes an important factor in rejection research. Attachment theory has been applied to understand psychological disorders, such as depression, and can explain individual differences in responses to rejection. Research on autonomic nervous system activity to rejection experiences has been contradictory, with opposing strings of argumentation (activating vs. numbing. We investigated autonomic nervous system-mediated peripheral physiological responses (heart rate to experimentally manipulated ostracism (Cyberball in 97 depressed patients with organized (n = 52 and disorganized attachment status (n = 45. Controlling for baseline mean heart rate levels, depressed patients with disorganized attachment status responded to ostracism with significantly higher increases in heart rate than depressed patients with organized attachment status (p = .029; ηp2 = .051. These results suggest that attachment status may be a useful indicator of autonomic responses to perceived social threat, which in turn may affect the therapeutic process and the patient-therapist relationship.

  1. Heart rate variability changes in physicians working on night call.

    Science.gov (United States)

    Malmberg, Birgitta; Persson, Roger; Flisberg, Per; Ørbaek, Palle

    2011-03-01

    Adverse effects by night-call duty have become an important occupational health issue. The aim of this study was to investigate whether the heart rate variability (HRV) differed during recovery from day work and night-call duty between distinct physician specialities. We studied the impact of a 16-h night-call duty on autonomic balance, measured by HRV, among two physician groups differing with respect to having to deal with life-threatening conditions while on call. Nineteen anaesthesiologists (ANEST) and 16 paediatricians and ear, nose and throat surgeons (PENT) were monitored by ambulatory digital Holter electrocardiogram (ECG). Heart rate variability was analysed between 21:00 and 22:00 after an ordinary workday, on night call and in the evening post-call. Absolute and normalized high-frequency power (HF, HFnu) were the main outcome variables, expressing parasympathetic influence on the heart. ANEST had lower HF power than PENT while on night call and post-daytime work (p work compared with post-night-call duty (p balance and did not differ between specialities. However, the less dynamic HRV after daytime work and during night-call duty in the ANEST group may indicate a higher physiological stress level. These results may contribute to the improvement of night-call schedules within the health care sector.

  2. The Effect of 8 Weeks Yoga Training on Respiratory Function and Heart Rate of Non-Athlete Females

    Directory of Open Access Journals (Sweden)

    KH

    2015-07-01

    Conclusions: Results of this study showed that 8 weeks of practicing yoga and pranayama to increase vital capacity and forced expiratory volume in the first second and decreased heart rate and respiratory rate at rest is. Keywords: Yoga, Pranayama, spirometric indices, heart rate

  3. Playing a violent television game affects heart rate variability.

    Science.gov (United States)

    Ivarsson, Malena; Anderson, Martin; Akerstedt, Torbjörn; Lindblad, Frank

    2009-01-01

    To investigate how playing a violent/nonviolent television game during the evening affects sympathetic and parasympathetic reactions during and after playing as well as sleep quality during the night after playing. In total, 19 boys, 12-15 years of age, played television games on two occasions in their homes and participated once without gaming. Heart rate, heart rate variability (HRV) and physical activity were measured during gaming/participating and the night to follow using a portable combined heart rate and movement sensor. A sleep diary and questionnaires about gaming experiences and session-specific experiences were filled in. Criteria for Selection of Games: Violent game involves/rewards direct physical violence (no handguns) against another person, and nonviolent game involves/rewards no violence; same game design ('third-person game'); conducted in the same manner; no differences concerning motor activity; similar sound and light effects; no sexual content, violence against women or racial overtones. During violent (vs. nonviolent) gaming, there was significantly higher activity of the very low frequency component of the HRV and total power. During the night after playing, very low frequency, low frequency and high frequency components were significantly higher during the violent (vs. nonviolent) condition, just as total power. There were no significant differences between the three conditions (violent/nonviolent/no gaming) with respect to an index reflecting subjectively perceived sleep difficulties. Nor was there any difference between violent and nonviolent condition for any single sleep item. Violent gaming induces different autonomic responses in boys compared to nonviolent gaming--during playing and during the following night--suggesting different emotional responses. Subjectively perceived sleep quality is not influenced after a single gaming experience. Future studies should address the development of the autonomic balance after gaming over longer

  4. High resolution heart rate variability analysis in patients with angina pectoris during coronary artery bypass graft surgery

    Science.gov (United States)

    Mironov, V. A.; Mironova, T. F.; Kuvatov, V. A.; Nokhrina, O. Yu.; Kuvatova, E. V.

    2017-12-01

    The purpose of the study is approbation of the capabilities of high-resolution rhythmocardiography (RCG) for the determination of the actual cardiovascular status of operated patients with angina pectoris during coronary artery bypass graft surgery (CABGS) for myocardial revascularization. The research was done by means of a KAP-RK-02-Mikor hardware-software complex with a monitor record and the time- and frequency-domain analyses of heart rate variability (HRV). Monitor records were made at each stage of CABGS in 123 patients. As a result, HRV manifested itself as a fairly adequate and promising method for the determination of the cardiovascular status during CABGS. In addition, the data of the HRV study during CABGS testify to the capability of RCG to determine the high risk of life-threatening cardioarrhythmias before and during operation, to different changes in sinoatrial heart node (SN) dysregulation, and contain the HRV symptoms of a high death risk before, during and after shunting. The loss of the peripheral autonomic sympathetic and parasympathetic control in SN in the form of the autonomic cardioneuropathy syndrome is a predictor of the complications related to CABGS. The obtained data on RCG monitoring of HRV recording are suggestive of wide prospects of the high-resolution RCG method to be used in cardiac surgery as a whole. The actual multivariant dysregulations of SN pacemaker activity testify to its adequacy to the pathophysiology of each period of the cardiac operation, according to the initial ischemic damages and localization of cardiosurgical manipulations during CABGS.

  5. Self-rating level of perceived exertion for guiding exercise intensity during a 12-week cardiac rehabilitation programme and the influence of heart rate reducing medication

    DEFF Research Database (Denmark)

    Tang, Lars H.; Zwisler, Ann-Dorthe; Taylor, Rod S

    2016-01-01

    OBJECTIVES: To investigate whether self-rating level of perceived exertion can adequately guide exercise intensity during a 12-week cardiac rehabilitation programme. DESIGN: Linear regression analysis using rehabilitation data from two randomised controlled trials. METHODS: Patients undergoing ra......-led and self-regulated model using rating of perceived exertion can help guide exercise intensity in everyday clinical practice among patients with heart disease, irrespective if they are taking heart rate-reducing medication....... radiofrequency ablation for atrial fibrillation or following heart valve surgery and participating in exercise-based rehabilitation were included. The 12-week rehabilitation outpatient programme comprised three weekly training sessions, each consisting of 20min aerobic exercise divided into three steps. Patients...... were asked to base their exercise intensity for each step on a predefined rating of perceived exertion specified in a training diary. Exercise intensity was objectively measured by heart rate during the last 2min for each exercise step. Comparative analysis and linear regression of the rating...

  6. The Influence of Motor Impairment on Autonomic Heart Rate Modulation among Children with Cerebral Palsy

    Science.gov (United States)

    Zamuner, Antonio Roberto; Cunha, Andrea Baraldi; da Silva, Ester; Negri, Ana Paola; Tudella, Eloisa; Moreno, Marlene Aparecida

    2011-01-01

    The study of heart rate variability is an important tool for a noninvasive evaluation of the neurocardiac integrity. The present study aims to evaluate the autonomic heart rate modulation in supine and standing positions in 12 children diagnosed with cerebral palsy and 16 children with typical motor development (control group), as well as to…

  7. Single unit activity in the medial prefrontal cortex during Pavlovian heart rate conditioning: Effects of peripheral autonomic blockade.

    Science.gov (United States)

    Powell, D A; Ginsberg, Jay P

    2005-11-01

    Electrical activity was recorded from single neurons in the medial prefrontal cortex of rabbits during differential Pavlovian heart rate (HR) conditioning. A heterogeneous population of cells were found, some of which showed CS-evoked increases and others CS-evoked decreases in discharge, while some cells were biphasic. A subset of cells also showed trial-related changes in discharge that were related to acquisition of the HR discrimination between the reinforced CS+ and non-reinforced CS-. Administration of the peripheral cholinergic antagonist, methylscopolamine, and the andrenergic antagonist, atenolol, either increased or decreased maintained baseline activity of many cells, but had little or no effect on the CS-evoked activity of these cells. Waveform changes also did not result from administration of these drugs. This finding suggests that CS-evoked mPFC activity is not being driven by cardiac afferent input to CNS cardiac control centers. Previous studies have shown that ibotenic acid lesions of this area greatly decreases the magnitude of decelerative heart rate conditioned responses; the latter finding, plus the results of the present study, suggest that processing of CS/US contingencies by the prefrontal cortex contributes to the acquisition of autonomic changes during Pavlovian conditioning.

  8. Individual variability in heart rate recovery after standardized submaximal exercise

    NARCIS (Netherlands)

    van der Does, Hendrike; Brink, Michel; Visscher, Chris; Lemmink, Koen

    2012-01-01

    To optimize performance, coaches and athletes are always looking for the right balance between training load and recovery. Therefore, closely monitoring of athletes is important. Heart rate recovery (HRR) after standardized sub maximal exercise has been proposed as a useful variable to monitor

  9. The intubating laryngeal mask produces less heart rate response to ...

    African Journals Online (AJOL)

    Pc

    We compared heart rate and blood pressure changes to intubation produced by conventional laryngoscopic-guided intubation to those produced by blind intubation through the intubating laryngeal mask (ILM) in normotensive adults with normal airways. Forty paralysed, anaesthetised adults undergoing elective surgery ...

  10. Relationship between exercise heart rate and music tempo preference

    OpenAIRE

    Karageorghis, CI; Jones, L; Low, DC

    2006-01-01

    The present study examined the predicted positive and linear relationship (Iwanaga, 1995a,1995b) between exercise heart rate and music tempo preference. Initially, 128 undergraduates (M 3 age = 20.0 years, SD = 0.9 years) were surveyed to establish their three favorite music artists of all time. A separate experimental group of 29 undergraduates (M age = 20.3 years, SD = 1.2 years) selected the music of a single artist from a choice of the three highest-rated artists from the earlier survey. ...

  11. Intermittent Auscultation for Intrapartum Fetal Heart Rate Surveillance: American College of Nurse-Midwives.

    Science.gov (United States)

    2015-01-01

    Fetal heart rate surveillance is a standard component of intrapartum care. The fetal heart rate can be evaluated using intermittent auscultation or electronic fetal monitoring. Research that has compared these 2 strategies found them to be equivalent with respect to long-term neonatal outcomes. The purpose of this clinical bulletin by the American College of Nurse-Midwives is to review the evidence for use of intermittent auscultation and provide recommendations for intermittent auscultation technique, interpretation, and documentation. © 2015 by the American College of Nurse-Midwives.

  12. Deficient maternal zinc intake-but not folate-is associated with lower fetal heart rate variability.

    Science.gov (United States)

    Spann, Marisa N; Smerling, Jennifer; Gustafsson, Hanna; Foss, Sophie; Altemus, Margaret; Monk, Catherine

    2015-03-01

    Few studies of maternal prenatal diet and child development examine micronutrient status in relation to fetal assessment. Twenty-four-hour dietary recall of zinc and folate and 20min of fetal heart rate were collected from 3rd trimester pregnant adolescents. Deficient zinc was associated with less fetal heart rate variability. Deficient folate had no associations with HRV. Neither deficient zinc nor deficient folate was related to fetal heart rate. These findings, from naturalistic observation, are consistent with emerging data on prenatal zinc supplementation using a randomized control design. Taken together, the findings suggest that maternal prenatal zinc intake is an important and novel factor for understanding child ANS development. Copyright © 2015. Published by Elsevier Ireland Ltd.

  13. Deficient maternal zinc intake—but not folate—is associated with lower fetal heart rate variability

    Science.gov (United States)

    Spann, Marisa N.; Smerling, Jennifer; Gustafsson, Hanna; Foss, Sophie; Altemus, Margaret; Monk, Catherine

    2015-01-01

    Objective Few studies of maternal prenatal diet and child development examine micronutrient status in relation to fetal assessment. Methods Twenty-four-hour dietary recall of zinc and folate and 20min of fetal heart rate were collected from 3rd trimester pregnant adolescents. Results Deficient zinc was associated with less fetal heart rate variability. Deficient folate had no associations with HRV. Neither deficient zinc nor deficient folate was related to fetal heart rate. Conclusions These findings, from naturalistic observation, are consistent with emerging data on prenatal zinc supplementation using a randomized control design. Practical Implication Taken together, the findings suggest that maternal prenatal zinc intake is an important and novel factor for understanding child ANS development. PMID:25658874

  14. Effect of Smoking on Blood Pressure and Resting Heart Rate

    DEFF Research Database (Denmark)

    Linneberg, Allan; Jacobsen, Rikke K; Skaaby, Tea

    2015-01-01

    BACKGROUND: -Smoking is an important cardiovascular disease risk factor, but the mechanisms linking smoking to blood pressure are poorly understood. METHODS AND RESULTS: -Data on 141,317 participants (62,666 never, 40,669 former, 37,982 current smokers) from 23 population-based studies were...... for smoking heaviness in current smokers. In observational analyses, current as compared with never smoking was associated with lower SBP, DBP, and lower hypertension risk, but with higher resting heart rate. In observational analyses amongst current smokers, one cigarette/day higher level of smoking...... heaviness was associated with higher (0.21 beats/minute; 95% CI 0.19; 0.24) resting heart rate, and slightly higher DBP (0.05 mmHg; 95% CI 0.02; 0.08) and SBP (0.08 mmHg; 95% CI 0.03; 0.13). However, in MR analyses amongst current smokers, while each smoking increasing allele of rs16969968/rs1051730...

  15. Retrospective low heart rate variability overview in Jos, Nigeria ...

    African Journals Online (AJOL)

    Result: Subjects with low HRV were older (51 vs 42, p=<0.05) years with low mean heart rate p=<0.05, compared to those with normal HRV. They all had severe features of cardiac dysfunction. Females with low HRV had decreased frequency of premature atrial contraction (PACs) (52% vs 78%). Only 5 (28%) cases out of ...

  16. Neighborhood blight, stress, and health: a walking trial of urban greening and ambulatory heart rate

    Science.gov (United States)

    Eugenia C. South; Michelle C. Kondo; Rose A. Cheney; Charles C. Branas

    2015-01-01

    We measured dynamic stress responses using ambulatory heart rate monitoring as participants in Philadelphia, Pennsylvania walked past vacant lots before and after a greening remediation treatment of randomly selected lots. Being in view of a greened vacant lot decreased heart rate significantly more than did being in view of a nongreened vacant lot or not in view of...

  17. Effects of vasoactive intestinal polypeptide on heart rate in relation to vagal cardioacceleration in conscious dogs

    NARCIS (Netherlands)

    Roossien, A; Brunstig, J.R; Nijmeijer, A; Zaagsma, Hans; Zijlstra, W.G

    Objective: The vagal cardiac accelerator (VCA) system takes part in the nervous control of the heart rate. In the present study we tried to adduce evidence that vasoactive intestinal polypeptide (VLP) contributes to vagally induced cardioacceleration. Methods: The effect of VIP on heart rate and

  18. Humoral regulation of heart rate during digestion in pythons (Python molurus and Python regius).

    Science.gov (United States)

    Enok, Sanne; Simonsen, Lasse Stærdal; Pedersen, Signe Vesterskov; Wang, Tobias; Skovgaard, Nini

    2012-05-15

    Pythons exhibit a doubling of heart rate when metabolism increases several times during digestion. Pythons, therefore, represent a promising model organism to study autonomic cardiovascular regulation during the postprandial state, and previous studies show that the postprandial tachycardia is governed by a release of vagal tone as well as a pronounced stimulation from nonadrenergic, noncholinergic (NANC) factors. Here we show that infusion of plasma from digesting donor pythons elicit a marked tachycardia in fasting snakes, demonstrating that the NANC factor resides in the blood. Injections of the gastrin and cholecystokinin receptor antagonist proglumide had no effect on double-blocked heart rate or blood pressure. Histamine has been recognized as a NANC factor in the early postprandial period in pythons, but the mechanism of its release has not been identified. Mast cells represent the largest repository of histamine in vertebrates, and it has been speculated that mast cells release histamine during digestion. Treatment with the mast cell stabilizer cromolyn significantly reduced postprandial heart rate in pythons compared with an untreated group but did not affect double-blocked heart rate. While this study indicates that histamine induces postprandial tachycardia in pythons, its release during digestion is not stimulated by gastrin or cholecystokinin nor is its release from mast cells a stimulant of postprandial tachycardia.

  19. Heart-rate variability and precompetitive anxiety in swimmers

    OpenAIRE

    Cervantes Blásquez, Julio César

    2009-01-01

    The aim of this study was to test the utility of heart-rate variability (HRV) analyses as a noninvasive means of quantifying cardiac autonomic regulation during precompetitive anxiety situations in swimmers. Psychophysiological state evaluation of 10 volunteer «master» swimmers (6 women and 4 men) was obtained by comparing baseline training condition (TC) with competition condition (CC). Self-evaluation of precompetitive somatic anxiety measured by CSAI-2 showed significant increase from the ...

  20. Reductions in Children's Vicariously Learnt Avoidance and Heart Rate Responses Using Positive Modeling.

    Science.gov (United States)

    Reynolds, Gemma; Field, Andy P; Askew, Chris

    2016-03-23

    Recent research has indicated that vicarious learning can lead to increases in children's fear beliefs and avoidance preferences for stimuli and that these fear responses can subsequently be reversed using positive modeling (counterconditioning). The current study investigated children's vicariously acquired avoidance behavior, physiological responses (heart rate), and attentional bias for stimuli and whether these could also be reduced via counterconditioning. Ninety-six (49 boys, 47 girls) 7- to 11-year-olds received vicarious fear learning for novel stimuli and were then randomly assigned to a counterconditioning, extinction, or control group. Fear beliefs and avoidance preferences were measured pre- and post-learning, whereas avoidance behavior, heart rate, and attentional bias were all measured post-learning. Control group children showed increases in fear beliefs and avoidance preferences for animals seen in vicarious fear learning trials. In addition, significantly greater avoidance behavior, heart rate responding, and attentional bias were observed for these animals compared to a control animal. In contrast, vicariously acquired avoidance preferences of children in the counterconditioning group were significantly reduced post-positive modeling, and these children also did not show the heightened heart rate responding to fear-paired animals. Children in the extinction group demonstrated comparable responses to the control group; thus the extinction procedure showed no effect on any fear measures. The findings suggest that counterconditioning with positive modelling can be used as an effective early intervention to reduce the behavioral and physiological effects of vicarious fear learning in childhood.