WorldWideScience

Sample records for hanging drop vapor

  1. Controlling Vapor Pressure In Hanging-Drop Crystallization

    Science.gov (United States)

    Carter, Daniel C.; Smith, Robbie

    1988-01-01

    Rate of evaporation adjusted to produce larger crystals. Device helps to control vapor pressure of water and other solvents in vicinity of hanging drop of solution containing dissolved enzyme protein. Well of porous frit (sintered glass) holds solution in proximity to drop of solution containing protein or enzyme. Vapor from solution in frit controls evaporation of solvent from drop to control precipitation of protein or enzyme. With device, rate of nucleation limited to decrease number and increase size (and perhaps quality) of crystals - large crystals of higher quality needed for x-ray diffraction studies of macromolecules.

  2. Axisymmetric Liquid Hanging Drops

    Science.gov (United States)

    Meister, Erich C.; Latychevskaia, Tatiana Yu

    2006-01-01

    The geometry of drops hanging on a circular capillary can be determined by numerically solving a dimensionless differential equation that is independent on any material properties, which enables one to follow the change of the height, surface area, and contact angle of drops hanging on a particular capillary. The results show that the application…

  3. Hanging drop crystal growth apparatus

    Science.gov (United States)

    Naumann, Robert J. (Inventor); Witherow, William K. (Inventor); Carter, Daniel C. (Inventor); Bugg, Charles E. (Inventor); Suddath, Fred L. (Inventor)

    1990-01-01

    This invention relates generally to control systems for controlling crystal growth, and more particularly to such a system which uses a beam of light refracted by the fluid in which crystals are growing to detect concentration of solutes in the liquid. In a hanging drop apparatus, a laser beam is directed onto drop which refracts the laser light into primary and secondary bows, respectively, which in turn fall upon linear diode detector arrays. As concentration of solutes in drop increases due to solvent removal, these bows move farther apart on the arrays, with the relative separation being detected by arrays and used by a computer to adjust solvent vapor transport from the drop. A forward scattering detector is used to detect crystal nucleation in drop, and a humidity detector is used, in one embodiment, to detect relative humidity in the enclosure wherein drop is suspended. The novelty of this invention lies in utilizing angular variance of light refracted from drop to infer, by a computer algorithm, concentration of solutes therein. Additional novelty is believed to lie in using a forward scattering detector to detect nucleating crystallites in drop.

  4. Laser scattering in a hanging drop vapor diffusion apparatus for protein crystal growth in a microgravity environment

    Science.gov (United States)

    Casay, G. A.; Wilson, W. W.

    1992-01-01

    One type of hardware used to grow protein crystals in the microgravity environment aboard the U.S. Space Shuttle is a hanging drop vapor diffusion apparatus (HDVDA). In order to optimize crystal growth conditions, dynamic control of the HDVDA is desirable. A critical component in the dynamically controlled system is a detector for protein nucleation. We have constructed a laser scattering detector for the HDVDA capable of detecting the nucleation stage. The detector was successfully tested for several scatterers differing in size using dynamic light scattering techniques. In addition, the ability to detect protein nucleation using the HDVDA was demonstrated for lysozyme.

  5. Model for determining vapor equilibrium rates in the hanging drop method for protein crystal growth

    Science.gov (United States)

    Baird, James K.; Frieden, Richard W.; Meehan, E. J., Jr.; Twigg, Pamela J.; Howard, Sandra B.; Fowlis, William A.

    1987-01-01

    An engineering analysis of the rate of evaporation of solvent in the hanging drop method of protein crystal growth is presented. Results are applied to 18 drop and well arrangements commonly encountered in the laboratory. The chemical nature of the salt, drop size and shape, drop concentration, well size, well concentration, and temperature are taken into account. The rate of evaporation increases with temperature, drop size, and the salt concentration difference between the drop and the well. The evaporation in this model possesses no unique half-life. Once the salt in the drop achieves 80 percent of its final concentration, further evaporation suffers from the law of diminishing returns.

  6. Propelling a water drop with the vapor-mediated Marangoni effect

    Science.gov (United States)

    Kim, Seungho; Kim, Ho-Young

    2013-11-01

    We show that a water drop on solid surfaces can be propelled just by placing a volatile alcohol drop nearby. It is found to be because the water-air interface near the alcohol drop mixes with alcohol vapor, thereby locally lowering the surface tension. The surface-tension-gradient induces the motion of the water drop, enabling the trajectory control of water drops through the motion of remote alcohol drops. This vapor-mediated Marangoni effect also gives rise to other interesting interfacial flow phenomena, such as nucleation of holes on a water film and ballooning of a water drop hanging from a syringe needle with the approach of an alcohol drop. We visualize such interfacial dynamics with a high-speed camera and rationalize their salient features by scaling analysis. This work was supported by the National Research Foundation of Korea (grant no. 2012-008023).

  7. Fabrication and Operation of Microfluidic Hanging-Drop Networks.

    Science.gov (United States)

    Misun, Patrick M; Birchler, Axel K; Lang, Moritz; Hierlemann, Andreas; Frey, Olivier

    2018-01-01

    The hanging-drop network (HDN) is a technology platform based on a completely open microfluidic network at the bottom of an inverted, surface-patterned substrate. The platform is predominantly used for the formation, culturing, and interaction of self-assembled spherical microtissues (spheroids) under precisely controlled flow conditions. Here, we describe design, fabrication, and operation of microfluidic hanging-drop networks.

  8. Experimental and theoretical analysis of the rate of solvent equilibration in the hanging drop method of protein crystal growth

    Science.gov (United States)

    Fowlis, William W.; Delucas, Lawrence J.; Twigg, Pamela J.; Howard, Sandra B.; Meehan, Edward J.

    1988-01-01

    The principles of the hanging-drop method of crystal growth are discussed, and the rate of water evaporation in a water droplet (containing protein, buffer, and a precipitating agent) suspended above a well containing a double concentration of precipitating agent is investigated theoretically. It is shown that, on earth, the rate of evaporation may be determined from diffusion theory and the colligative properties of solutions. The parameters affecting the rate of evaporation include the temperature, the vapor pressure of water, the ionization constant of the salt, the volume of the drop, the contact angle between the droplet and the coverslip, the number of moles of salt in the droplet, the number of moles of water and salt in the well, the molar volumes of water and salt, the distance from the droplet to the well, and the coefficient of diffusion of water vapor through air. To test the theoretical equations, hanging-drop experiments were conducted using various reagent concentrations in 25-microliter droplets and measuring the evaporation times at 4 C and 25 C. The results showed good agreement with the theory.

  9. Hanging drop cultures of human testis and testis cancer samples

    DEFF Research Database (Denmark)

    Jørgensen, Anne; Young, J; Nielsen, J E

    2014-01-01

    cultured in 'hanging drops' and effects of activin A and follistatin treatment were investigated in seminoma cultures. RESULTS: Testis fragments with normal spermatogenesis or CIS cells were cultured for 14 days with sustained proliferation of germ cells and CIS cells and without increased apoptosis....... Seminoma cultures survived 7 days, with proliferating cells detectable during the first 5 days. Activin A treatment significantly reduced KIT transcript and protein levels in seminoma cultures, thereby demonstrating a specific treatment response. CONCLUSIONS: Hanging drop cultures of human testis...

  10. Adding the 'heart' to hanging drop networks for microphysiological multi-tissue experiments.

    Science.gov (United States)

    Rismani Yazdi, Saeed; Shadmani, Amir; Bürgel, Sebastian C; Misun, Patrick M; Hierlemann, Andreas; Frey, Olivier

    2015-11-07

    Microfluidic hanging-drop networks enable culturing and analysis of 3D microtissue spheroids derived from different cell types under controlled perfusion and investigating inter-tissue communication in multi-tissue formats. In this paper we introduce a compact on-chip pumping approach for flow control in hanging-drop networks. The pump includes one pneumatic chamber located directly above one of the hanging drops and uses the surface tension at the liquid-air-interface for flow actuation. Control of the pneumatic protocol provides a wide range of unidirectional pulsatile and continuous flow profiles. With the proposed concept several independent hanging-drop networks can be operated in parallel with only one single pneumatic actuation line at high fidelity. Closed-loop medium circulation between different organ models for multi-tissue formats and multiple simultaneous assays in parallel are possible. Finally, we implemented a real-time feedback control-loop of the pump actuation based on the beating of a human iPS-derived cardiac microtissue cultured in the same system. This configuration allows for simulating physiological effects on the heart and their impact on flow circulation between the organ models on chip.

  11. Hanging drop crystal growth apparatus and method

    Science.gov (United States)

    Carter, Daniel C. (Inventor); Smith, Robbie E. (Inventor)

    1989-01-01

    An apparatus (10) is constructed having a cylindrical enclosure (16) within which a disc-shaped wicking element (18) is positioned. A well or recess (22) is cut into an upper side (24) of this wicking element, and a glass cover plate or slip (28) having a protein drop disposed thereon is sealably positioned on the wicking element (18), with drop (12) being positioned over well or recess (22). A flow of control fluid is generated by a programmable gradient former (16), with this control fluid having a vapor pressure that is selectively variable. This flow of control fluid is coupled to the wicking element (18) where control fluid vapor diffusing from walls (26) of the recess (22) is exposed to the drop (12), forming a vapor pressure gradient between the drop (12) and the control fluid vapor. Initially, this gradient is adjusted to draw solvent from the drop (12) at a relatively high rate, and as the critical supersaturation point is approached (the point at which crystal nucleation occurs), the gradient is reduced to more slowly draw solvent from the drop (12). This allows discrete protein molecules more time to orient themselves into an ordered crystalline lattice, producing protein crystals which, when processed by X-ray crystallography, possess a high degree of resolution.

  12. A hanging drop culture method to study terminal erythroid differentiation.

    Science.gov (United States)

    Gutiérrez, Laura; Lindeboom, Fokke; Ferreira, Rita; Drissen, Roy; Grosveld, Frank; Whyatt, David; Philipsen, Sjaak

    2005-10-01

    To design a culture method allowing the quantitative and qualitative analysis of terminal erythroid differentiation. Primary erythroid progenitors derived either from mouse tissues or from human umbilical cord blood were differentiated using hanging drop cultures and compared to methylcellulose cultures. Cultured cells were analyzed by FACS to assess differentiation. We describe a practical culture method by adapting the previously described hanging drop culture system to conditions allowing terminal differentiation of primary erythroid progenitors. Using minimal volumes of media and small numbers of cells, we obtained quantitative terminal erythroid differentiation within two days of culture in the case of murine cells and 4 days in the case of human cells. The established methods for ex vivo culture of primary erythroid progenitors, such as methylcellulose-based burst-forming unit-erythroid (BFU-E) and colony-forming unit-erythroid (CFU-E) assays, allow the detection of committed erythroid progenitors but are of limited value to study terminal erythroid differentiation. We show that the application of hanging drop cultures is a practical alternative that, in combination with clonogenic assays, enables a comprehensive assessment of the behavior of primary erythroid cells ex vivo in the context of genetic and drug-induced perturbations.

  13. Characterization and reproducibility of HepG2 hanging drop spheroids toxicology in vitro.

    Science.gov (United States)

    Hurrell, Tracey; Ellero, Andrea Antonio; Masso, Zelie Flavienne; Cromarty, Allan Duncan

    2018-02-21

    Hepatotoxicity remains a major challenge in drug development despite preclinical toxicity screening using hepatocytes of human origin. To overcome some limitations of reproducing the hepatic phenotype, more structurally and functionally authentic cultures in vitro can be introduced by growing cells in 3D spheroid cultures. Characterisation and reproducibility of HepG2 spheroid cultures using a high-throughput hanging drop technique was performed and features contributing to potential phenotypic variation highlighted. Cultured HepG2 cells were seeded into Perfecta 3D® 96-well hanging drop plates and assessed over time for morphology, viability, cell cycle distribution, protein content and protein-mass profiles. Divergent aspects which were assessed included cell stocks, seeding density, volume of culture medium and use of extracellular matrix additives. Hanging drops are advantageous due to no complex culture matrix being present, enabling background free extractions for downstream experimentation. Varying characteristics were observed across cell stocks and batches, seeding density, culture medium volume and extracellular matrix when using immortalized HepG2 cells. These factors contribute to wide-ranging cellular responses and highlights concerns with respect to generating a reproducible phenotype in HepG2 hanging drop spheroids. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Adding the ‘heart’ to hanging drop networks for microphysiological multi-tissue experiments†

    Science.gov (United States)

    Yazdi, Saeed Rismani; Shadmani, Amir; Bürgel, Sebastian C.; Misun, Patrick M.; Hierlemann, Andreas; Frey, Olivier

    2017-01-01

    Microfluidic hanging-drop networks enable culturing and analysis of 3D microtissue spheroids derived from different cell types under controlled perfusion and investigating inter-tissue communication in multi-tissue formats. In this paper we introduce a compact on-chip pumping approach for flow control in hanging-drop networks. The pump includes one pneumatic chamber located directly above one of the hanging drops and uses the surface tension at the liquid–air-interface for flow actuation. Control of the pneumatic protocol provides a wide range of unidirectional pulsatile and continuous flow profiles. With the proposed concept several independent hanging-drop networks can be operated in parallel with only one single pneumatic actuation line at high fidelity. Closed-loop medium circulation between different organ models for multi-tissue formats and multiple simultaneous assays in parallel are possible. Finally, we implemented a real-time feedback control-loop of the pump actuation based on the beating of a human iPS-derived cardiac microtissue cultured in the same system. This configuration allows for simulating physiological effects on the heart and their impact on flow circulation between the organ models on chip. PMID:26401602

  15. Optimal Population of Embryonic Stem Cells in "Hanging Drop" Culture for in-vitro Differentiation to Cardiac Myocytes

    OpenAIRE

    MIWA, Keiko; LEE, Jong-Kook; HIDAKA, Kyoko; SHI, Rong-qian; MORISAKI, Takayuki; KODAMA, Itsuo

    2002-01-01

    Pluripotent embryonic stem (ES) cells differentiate to cardiac myocytes in vitro by many other previous reports demonstrated "hanging-drop" method. In this study, the number of ES cells in each hanging-drop plays an important role in the cultivation of cardiac myocytes. We examined the optimal hanging-drop size to obtain embryonic stem cell-derived cardiac cells (ESCMs) in vitro using specific labeled mouse ES cells (hCGP7) which were stably transfected with the enhanced green fluorescent pro...

  16. Reconfigurable microfluidic hanging drop network for multi-tissue interaction and analysis.

    Science.gov (United States)

    Frey, Olivier; Misun, Patrick M; Fluri, David A; Hengstler, Jan G; Hierlemann, Andreas

    2014-06-30

    Integration of multiple three-dimensional microtissues into microfluidic networks enables new insights in how different organs or tissues of an organism interact. Here, we present a platform that extends the hanging-drop technology, used for multi-cellular spheroid formation, to multifunctional complex microfluidic networks. Engineered as completely open, 'hanging' microfluidic system at the bottom of a substrate, the platform features high flexibility in microtissue arrangements and interconnections, while fabrication is simple and operation robust. Multiple spheroids of different cell types are formed in parallel on the same platform; the different tissues are then connected in physiological order for multi-tissue experiments through reconfiguration of the fluidic network. Liquid flow is precisely controlled through the hanging drops, which enable nutrient supply, substance dosage and inter-organ metabolic communication. The possibility to perform parallelized microtissue formation on the same chip that is subsequently used for complex multi-tissue experiments renders the developed platform a promising technology for 'body-on-a-chip'-related research.

  17. Application of hanging drop technique to optimize human IgG formulations.

    Science.gov (United States)

    Li, Guohua; Kasha, Purna C; Late, Sameer; Banga, Ajay K

    2010-01-01

    The purpose of this work is to assess the hanging drop technique in screening excipients to develop optimal formulations for human immunoglobulin G (IgG). A microdrop of human IgG and test solution hanging from a cover slide and undergoing vapour diffusion was monitored by a stereomicroscope. Aqueous solutions of IgG in the presence of different pH, salt concentrations and excipients were prepared and characterized. Low concentration of either sodium/potassium phosphate or McIlvaine buffer favoured the solubility of IgG. Addition of sucrose favoured the stability of this antibody while addition of NaCl caused more aggregation. Antimicrobial preservatives were also screened and a complex effect at different buffer conditions was observed. Dynamic light scattering, differential scanning calorimetry and size exclusion chromatography studies were performed to further validate the results. In conclusion, hanging drop is a very easy and effective approach to screen protein formulations in the early stage of formulation development.

  18. Culturing muscle fibres in hanging drop: a novel approach to solve an old problem.

    Science.gov (United States)

    Archacka, Karolina; Pozzobon, Michela; Repele, Andrea; Rossi, Carlo Alberto; Campanella, Michelangelo; De Coppi, Paolo

    2014-02-01

    The satellite cells (SCs) associated with muscle fibres play a key role in postnatal growth and regeneration of skeletal muscle. Commonly used methods of isolation and in vitro culture of SCs lead to the mixture of their subpopulations that exist within muscle. To solve this problem, we used the well established technique, the hanging drop system, to culture SCs in a three-dimensional environment and thus, to monitor them in their original niche. Using hanging drop technique, we were able to culture SCs associated with the fibre at least for 9 days with one transfer of fibres to the fresh drops. In comparison, in the classical method of myofibres culture, that is, on the dishes coated with Matrigel, SCs leave the fibres within 3 days after the isolation. Cells cultured in both systems differed in expression of Pax7 and MyoD. While almost all cells cultured in adhesion system expressed MyoD before the fifth day of the culture, the majority of SCs cultured in hanging drop still maintained expression of Pax7 and were not characterised by the presence of MyoD. Among the cells cultured with single myofibre for up to 9 days, we identified two different subclones of SCs: low proliferative clone and high proliferative clone, which differed in proliferation rate and membrane potential. The hanging drop enables the myofibres to be kept in suspension for at least 9 days, and thus, allows SCs and their niche to interact each other for prolonged time. In a consequence, SCs cultured in hanging drop maintain expression of Pax7 while those cultured in a traditional adhesion culture, that is, devoid of signals from the original niche, activate and preferentially undergo differentiation as manifested by expression of MyoD. Thus, the innovative method of SCs culturing in the hanging drop system may serve as a useful tool to study the fate of different subpopulations of these cells in their anatomical location and to determine reciprocal interactions between them and their niche.

  19. Application of hanging drop technique for stem cell differentiation and cytotoxicity studies.

    Science.gov (United States)

    Banerjee, Meenal; Bhonde, Ramesh R

    2006-05-01

    The aim of our study is to explore the possibility of using an ancient method of culture technique- the hanging drop technique for stem cell differentiation and cytotoxicity testing. We demonstrate here a variety of novel applications of this age old technique not only to harness the differentiation potential of stem cells into specific lineages but also for cytotoxicity studies. Here we have prepared hanging drop cultures by placing 20 microl micro-drops of nutrient media and 10% Fetal Calf Serum (FCS) containing cells of interest on the lids of 60 mm dishes. Bottom plates of the dishes were filled with sterile Phosphate Buffer Saline (PBS) to avoid desiccation of samples. Lids were then placed on the bottom plates to achieve hanging drop cultures. We utilized this technique for cultivation of ciliated epithelia to study cytotoxicity and differentiation of bone marrow stromal cells. Most importantly the modified culture technique presented here is simple, economical and cost effective in terms of the time taken and the reagents required and are amenable to goal specific modification such as cytotoxicity testing. It is advantageous over the existing system in terms of retention of viability and functionality for longer duration and for providing three dimensional growth micro-environment making it useful for organotypic cultures and in vivo simulation.

  20. 384 hanging drop arrays give excellent Z-factors and allow versatile formation of co-culture spheroids.

    Science.gov (United States)

    Hsiao, Amy Y; Tung, Yi-Chung; Qu, Xianggui; Patel, Lalit R; Pienta, Kenneth J; Takayama, Shuichi

    2012-05-01

    We previously reported the development of a simple, user-friendly, and versatile 384 hanging drop array plate for 3D spheroid culture and the importance of utilizing 3D cellular models in anti-cancer drug sensitivity testing. The 384 hanging drop array plate allows for high-throughput capabilities and offers significant improvements over existing 3D spheroid culture methods. To allow for practical 3D cell-based high-throughput screening and enable broader use of the plate, we characterize the robustness of the 384 hanging drop array plate in terms of assay performance and demonstrate the versatility of the plate. We find that the 384 hanging drop array plate performance is robust in fluorescence- and colorimetric-based assays through Z-factor calculations. Finally, we demonstrate different plate capabilities and applications, including: spheroid transfer and retrieval for Janus spheroid formation, sequential addition of cells for concentric layer patterning of different cell types, and culture of a wide variety of cell types. Copyright © 2011 Wiley Periodicals, Inc.

  1. An optimized protocol for handling and processing fragile acini cultured with the hanging drop technique.

    Science.gov (United States)

    Snyman, Celia; Elliott, Edith

    2011-12-15

    The hanging drop three-dimensional culture technique allows cultivation of functional three-dimensional mammary constructs without exogenous extracellular matrix. The fragile acini are, however, difficult to preserve during processing steps for advanced microscopic investigation. We describe adaptations to the protocol for handling of hanging drop cultures to include investigation using confocal, scanning, and electron microscopy, with minimal loss of cell culture components. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Evaporation kinetics in the hanging drop method of protein crystal growth

    Science.gov (United States)

    Baird, James K.; Frieden, Richard W.; Meehan, E. J., Jr.; Twigg, Pamela J.; Howard, Sandra B.; Fowlis, William A.

    1987-01-01

    An engineering analysis of the rate of evaporation of solvent in the hanging drop method of protein crystal growth is presented; these results are applied to 18 different drop and well arrangements commonly encountered in the laboratory, taking into account the chemical nature of the salt, the drop size and shape, the drop concentration, the well size, the well concentration, and the temperature. It is found that the rate of evaporation increases with temperature, drop size, and with the salt concentration difference between the drop and the well. The evaporation possesses no unique half-life. Once the salt in the drop achieves about 80 percent of its final concentration, further evaporation suffers from the law of diminishing returns.

  3. The formation of intestinal organoids in a hanging drop culture.

    Science.gov (United States)

    Panek, Malgorzata; Grabacka, Maja; Pierzchalska, Malgorzata

    2018-01-25

    Recently organoids have become widely used in vitro models of many tissue and organs. These type of structures, originated from embryonic or adult mammalian intestines, are called "mini guts". They organize spontaneously when intestinal crypts or stem cells are embedded in the extracellular matrix proteins preparation scaffold (Matrigel). This approach has some disadvantages, as Matrigel is undefined (the concentrations of growth factors and other biologically active components in it may vary from batch to batch), difficult to handle and expensive. Here we show that the organoids derived from chicken embryo intestine are formed in a hanging drop without embedding, providing an attractive alternative for currently used protocols. Using this technique we obtained compact structures composed of contiguous organoids, which were generally similar to chicken organoids cultured in Matrigel in terms of morphology and expression of intestinal epithelial markers. Due to the simplicity, high reproducibility and throughput capacity of hanging drop technique our model may be applied in various studies concerning the gut biology.

  4. Application of Hanging Drop Technique for Kidney Tissue Culture.

    Science.gov (United States)

    Wang, Shaohui; Wang, Ximing; Boone, Jasmine; Wie, Jin; Yip, Kay-Pong; Zhang, Jie; Wang, Lei; Liu, Ruisheng

    2017-01-01

    The hanging drop technique is a well-established method used in culture of animal tissues. However, this method has not been used in adult kidney tissue culture yet. This study was to explore the feasibility of using this technique for culturing adult kidney cortex to study the time course of RNA viability in the tubules and vasculature, as well as the tissue structural integrity. In each Petri dish with the plate covered with sterile buffer, a section of mouse renal cortex was cultured within a drop of DMEM culture medium on the inner surface of the lip facing downward. The tissue were then harvested at each specific time points for Real-time PCR analysis and histological studies. The results showed that the mRNA level of most Na+ related transporters and cotransporters were stably maintained within 6 hours in culture, and that the mRNA level of most receptors found in the vasculature and glomeruli were stably maintained for up to 9 days in culture. Paraffin sections of the cultured renal cortex indicated that the tubules began to lose tubular integrity after 6 hours, but the glomeruli and vasculatures were still recognizable up to 9 days in culture. We concluded that adult kidney tissue culture by hanging drop method can be used to study gene expressions in vasculature and glomeruli. © 2017 The Author(s). Published by S. Karger AG, Basel.

  5. Application of Hanging Drop Technique for Kidney Tissue Culture

    Directory of Open Access Journals (Sweden)

    Shaohui Wang

    2017-05-01

    Full Text Available Background/Aims: The hanging drop technique is a well-established method used in culture of animal tissues. However, this method has not been used in adult kidney tissue culture yet. This study was to explore the feasibility of using this technique for culturing adult kidney cortex to study the time course of RNA viability in the tubules and vasculature, as well as the tissue structural integrity. Methods: In each Petri dish with the plate covered with sterile buffer, a section of mouse renal cortex was cultured within a drop of DMEM culture medium on the inner surface of the lip facing downward. The tissue were then harvested at each specific time points for Real-time PCR analysis and histological studies. Results: The results showed that the mRNA level of most Na+ related transporters and cotransporters were stably maintained within 6 hours in culture, and that the mRNA level of most receptors found in the vasculature and glomeruli were stably maintained for up to 9 days in culture. Paraffin sections of the cultured renal cortex indicated that the tubules began to lose tubular integrity after 6 hours, but the glomeruli and vasculatures were still recognizable up to 9 days in culture. Conclusions: We concluded that adult kidney tissue culture by hanging drop method can be used to study gene expressions in vasculature and glomeruli.

  6. In vitro differentiation of mouse embryonic stem (mES) cells using the hanging drop method.

    Science.gov (United States)

    Wang, Xiang; Yang, Phillip

    2008-07-23

    Stem cells have the remarkable potential to develop into many different cell types. When a stem cell divides, each new cell has the potential to either remain a stem cell or become another type of cell with a more specialized function, This promising of science is leading scientists to investigate the possibility of cell-based therapies to treat disease. When culture in suspension without antidifferentiation factors, embryonic stem cells spontaneously differentiate and form three-dimensional multicellular aggregates. These cell aggregates are called embryoid bodies(EB). Hanging drop culture is a widely used EB formation induction method. The rounded bottom of hanging drop allows the aggregation of ES cells which can provide mES cells a good environment for forming EBs. The number of ES cells aggregatied in a hanging drop can be controlled by varying the number of cells in the initial cell suspension to be hung as a drop from the lid of Petri dish. Using this method we can reproducibly form homogeneous EBs from a predetermined number of ES cells.

  7. Enhancement of nucleation during hanging drop protein crystallization using HF treatment of cover glasses

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Yun-Zhu; Yin, Da-Chuan; Lu, Qin-Qin; Wang, Xi-Kai; Liu, Jun [Key Laboratory for Space Bioscience and Biotechnology, Faculty of Life Sciences, Northwestern Polytechnical University, Xi' an 710072, Shaanxi (China)

    2010-02-15

    We examined a simple approach, i.e., etching cover glasses using hydrofluoric acid (HF), to determine whether cover glass treatment enhances nucleation in hanging drop protein crystallization. Hen egg white lysozyme and proteinase K were used as the model proteins. We found that the treatment increased the success rate of crystallization. The results indicated that the simple treatment, which is easy to adopt without changing much in the hanging drop method, can be utilized as an alternative method to enhance protein crystallization screens (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  8. Hanging colloidal drop: A new photonic crystal synthesis route

    Science.gov (United States)

    Sandu, Ion; Dumitru, Marius; Fleaca, Claudiu Teodor; Dumitrache, Florian

    2018-05-01

    High-quality photonic crystals (hundreds of micrometres in thickness) were grown by the free evaporation of a colloidal drop consisting of silica and polystyrene nanospheres with dimensions of 300 nm, 500 nm, and 1000 nm. The essence of experimental findings is that the drop has to hang on a pillar. This leads to the inhibition of the droplet spreading, the minimisation of the convective force, and the zeroing of the static frictional force between nanospheres and the liquid/air interface, where the first layer is formed. The theoretical essence is the continuous adjustment of nanospheres positions during the growth of photonic crystal, a key condition of the self-assembling phenomenon.

  9. The preparation of Drosophila embryos for live-imaging using the hanging drop protocol.

    Science.gov (United States)

    Reed, Bruce H; McMillan, Stephanie C; Chaudhary, Roopali

    2009-03-13

    Green fluorescent protein (GFP)-based timelapse live-imaging is a powerful technique for studying the genetic regulation of dynamic processes such as tissue morphogenesis, cell-cell adhesion, or cell death. Drosophila embryos expressing GFP are readily imaged using either stereoscopic or confocal microscopy. A goal of any live-imaging protocol is to minimize detrimental effects such as dehydration and hypoxia. Previous protocols for preparing Drosophila embryos for live-imaging analysis have involved placing dechorionated embryos in halocarbon oil and sandwiching them between a halocarbon gas-permeable membrane and a coverslip. The introduction of compression through mounting embryos in this manner represents an undesirable complication for any biomechanical-based analysis of morphogenesis. Our method, which we call the hanging drop protocol, results in excellent viability of embryos during live imaging and does not require that embryos be compressed. Briefly, the hanging drop protocol involves the placement of embryos in a drop of halocarbon oil that is suspended from a coverslip, which is, in turn, fixed in position over a humid chamber. In addition to providing gas exchange and preventing dehydration, this arrangement takes advantage of the buoyancy of embryos in halocarbon oil to prevent them from drifting out of position during timelapse acquisition. This video describes in detail how to collect and prepare Drosophila embryos for live imaging using the hanging drop protocol. This protocol is suitable for imaging dechorionated embryos using stereomicroscopy or any upright compound fluorescence microscope.

  10. [Culture of pancreatic progenitor cells in hanging drop and on floating filter].

    Science.gov (United States)

    Ma, Feng-xia; Chen, Fang; Chi, Ying; Yang, Shao-guang; Lu, Shi-hong; Han, Zhong-chao

    2013-06-01

    To construct a method to culture pancreatic progenitor cells in hanging drop and on floating filter,and to examine if pancreatic progenitor cells can differentiate into mature endocrine cells with this method. Murine embryos at day 12.5 were isolated and digested into single cells,which were then cultured in hanging drop for 24h and formed spheres.Spheres were cultured on the filter for 6 days,which floated in the dish containing medium.During culture,the expressions of pancreas duodenum homeobox-1(PDX-1)and neurogenin3(Ngn3)were determined.The expressions of endocrine and exocrine markers,insulin,glucagon,and carboxypeptidase(CPA)were determined on day 7 by immunohistochemistry.Insulin secretion of spheres stimulated by glucose was detected by ELISA.The changes of pancreatic marker expressions during culture were monitored by real-time polymerase chain reaction(PCR). One day after the culture,there were still a large amount of PDX-1 positive cells in pancreatic spheres,and these cells proliferated.On day 3,high expression of Ngn3 was detected,and the Ngn3-positive cells did not proliferate.On day 7,The expressions of endocrine and exocrine markers in the differentiated pancreatic progenitor cells were detected,which were consistent with that in vivo.Insulin was secreted by spheres upon the stimulation of glucose. In hanging drop and on floating filter,pancreatic progenitor cells can differentiate into mature endocrine cells.

  11. Three-dimensional culture of buffalo granulosa cells in hanging drop mimics the preovulatory follicle stage.

    Science.gov (United States)

    Yadav, Monica; Agrawal, Himanshu; Pandey, Mamta; Singh, Dheer; Onteru, Suneel K

    2018-03-01

    Granulosa cell (GC) culture models mimicking the intrafollicular environment are limited. Such models have a great potential in reproductive toxicity studies. The buffalo, a monovulatory species like humans, could be a better model than polyovulatory rodents. Therefore, we targeted the development and characterization of three-dimensional (3D) culture systems for buffalo GCs. The GCs from small ovarian follicles (SF) maintained the CYP19 gene expression for 144 hr in a 2D culture system. Hence, GCs from SF were cultured directly in 3D using hanging drop and Poly-([2-hydroxyethyl methacrylate]) (polyHEMA) methods in the DMEM media containing 1 ng/ml FSH and 10 ng/ml IGF-1 for 144 hr. The expression profile of nine GC-specific transcripts; CYP19, TNFAIP6, AMH, PTI, NR4A1, FSHR, RUNX, LHR, and COX2/PTGS2; revealed that 3D-spheroids developed in hanging drop method maintained the GC phenotype of preovulatory follicles. Therefore, hanging drop method is a best method for culturing GCs to mimic the intrafollicular environment. © 2017 Wiley Periodicals, Inc.

  12. VOLTAMMETRY OF AQUEOUS CHLOROAURIC ACID WITH HANGING MERCURY DROP ELECTRODE

    Czech Academy of Sciences Publication Activity Database

    Korshunov, A.; Josypčuk, Bohdan; Heyrovský, Michael

    2011-01-01

    Roč. 76, č. 7 (2011), s. 929-936 ISSN 0010-0765 R&D Projects: GA ČR GAP206/11/1638; GA AV ČR IAA400400806; GA MŠk(CZ) LC06063 Institutional research plan: CEZ:AV0Z40400503 Keywords : aqueous chloauric acid * voltammetry * hanging mercury drop electrode Subject RIV: CG - Electrochemistry Impact factor: 1.283, year: 2011

  13. Generation of Homogenous Three-Dimensional Pancreatic Cancer Cell Spheroids Using an Improved Hanging Drop Technique.

    Science.gov (United States)

    Ware, Matthew J; Colbert, Kevin; Keshishian, Vazrik; Ho, Jason; Corr, Stuart J; Curley, Steven A; Godin, Biana

    2016-04-01

    In vitro characterization of tumor cell biology or of potential anticancer drugs is usually performed using tumor cell lines cultured as a monolayer. However, it has been previously shown that three-dimensional (3D) organization of the tumor cells is important to provide insights on tumor biology and transport of therapeutics. Several methods to create 3D tumors in vitro have been proposed, with hanging drop technique being the most simple and, thus, most frequently used. However, in many cell lines this method has failed to form the desired 3D tumor structures. The aim of this study was to design and test an easy-to-use and highly reproducible modification of the hanging drop method for tumor sphere formation by adding methylcellulose polymer. Most pancreatic cancer cells do not form cohesive and manageable spheres when the original hanging drop method is used, thus we investigated these cell lines for our modified hanging drop method. The spheroids produced by this improved technique were analyzed by histology, light microscopy, immunohistochemistry, and scanning electron microscopy. Results show that using the proposed simple method; we were able to produce uniform spheroids for all five of the tested human pancreatic cancer cell lines; Panc-1, BxPC-3, Capan-1, MiaPaCa-2, and AsPC-1. We believe that this method can be used as a reliable and reproducible technique to make 3D cancer spheroids for use in tumor biology research and evaluation of therapeutic responses, and for the development of bio-artificial tissues.

  14. A PDMS-Based Microfluidic Hanging Drop Chip for Embryoid Body Formation.

    Science.gov (United States)

    Wu, Huei-Wen; Hsiao, Yi-Hsing; Chen, Chih-Chen; Yet, Shaw-Fang; Hsu, Chia-Hsien

    2016-07-06

    The conventional hanging drop technique is the most widely used method for embryoid body (EB) formation. However, this method is labor intensive and limited by the difficulty in exchanging the medium. Here, we report a microfluidic chip-based approach for high-throughput formation of EBs. The device consists of microfluidic channels with 6 × 12 opening wells in PDMS supported by a glass substrate. The PDMS channels were fabricated by replicating polydimethyl-siloxane (PDMS) from SU-8 mold. The droplet formation in the chip was tested with different hydrostatic pressures to obtain optimal operation pressures for the wells with 1000 μm diameter openings. The droplets formed at the opening wells were used to culture mouse embryonic stem cells which could subsequently developed into EBs in the hanging droplets. This device also allows for medium exchange of the hanging droplets making it possible to perform immunochemistry staining and characterize EBs on chip.

  15. A PDMS-Based Microfluidic Hanging Drop Chip for Embryoid Body Formation

    Directory of Open Access Journals (Sweden)

    Huei-Wen Wu

    2016-07-01

    Full Text Available The conventional hanging drop technique is the most widely used method for embryoid body (EB formation. However, this method is labor intensive and limited by the difficulty in exchanging the medium. Here, we report a microfluidic chip-based approach for high-throughput formation of EBs. The device consists of microfluidic channels with 6 × 12 opening wells in PDMS supported by a glass substrate. The PDMS channels were fabricated by replicating polydimethyl-siloxane (PDMS from SU-8 mold. The droplet formation in the chip was tested with different hydrostatic pressures to obtain optimal operation pressures for the wells with 1000 μm diameter openings. The droplets formed at the opening wells were used to culture mouse embryonic stem cells which could subsequently developed into EBs in the hanging droplets. This device also allows for medium exchange of the hanging droplets making it possible to perform immunochemistry staining and characterize EBs on chip.

  16. Digital microfluidics for automated hanging drop cell spheroid culture.

    Science.gov (United States)

    Aijian, Andrew P; Garrell, Robin L

    2015-06-01

    Cell spheroids are multicellular aggregates, grown in vitro, that mimic the three-dimensional morphology of physiological tissues. Although there are numerous benefits to using spheroids in cell-based assays, the adoption of spheroids in routine biomedical research has been limited, in part, by the tedious workflow associated with spheroid formation and analysis. Here we describe a digital microfluidic platform that has been developed to automate liquid-handling protocols for the formation, maintenance, and analysis of multicellular spheroids in hanging drop culture. We show that droplets of liquid can be added to and extracted from through-holes, or "wells," and fabricated in the bottom plate of a digital microfluidic device, enabling the formation and assaying of hanging drops. Using this digital microfluidic platform, spheroids of mouse mesenchymal stem cells were formed and maintained in situ for 72 h, exhibiting good viability (>90%) and size uniformity (% coefficient of variation <10% intraexperiment, <20% interexperiment). A proof-of-principle drug screen was performed on human colorectal adenocarcinoma spheroids to demonstrate the ability to recapitulate physiologically relevant phenomena such as insulin-induced drug resistance. With automatable and flexible liquid handling, and a wide range of in situ sample preparation and analysis capabilities, the digital microfluidic platform provides a viable tool for automating cell spheroid culture and analysis. © 2014 Society for Laboratory Automation and Screening.

  17. Micro-ring structures stabilize microdroplets to enable long term spheroid culture in 384 hanging drop array plates.

    Science.gov (United States)

    Hsiao, Amy Y; Tung, Yi-Chung; Kuo, Chuan-Hsien; Mosadegh, Bobak; Bedenis, Rachel; Pienta, Kenneth J; Takayama, Shuichi

    2012-04-01

    Using stereolithography, 20 different structural variations comprised of millimeter diameter holes surrounded by trenches, plateaus, or micro-ring structures were prepared and tested for their ability to stably hold arrays of microliter sized droplets within the structures over an extended period of time. The micro-ring structures were the most effective in stabilizing droplets against mechanical and chemical perturbations. After confirming the importance of micro-ring structures using rapid prototyping, we developed an injection molding tool for mass production of polystyrene 3D cell culture plates with an array of 384 such micro-ring surrounded through-hole structures. These newly designed and injection molded polystyrene 384 hanging drop array plates with micro-rings were stable and robust against mechanical perturbations as well as surface fouling-facilitated droplet spreading making them capable of long term cell spheroid culture of up to 22 days within the droplet array. This is a significant improvement over previously reported 384 hanging drop array plates which are susceptible to small mechanical shocks and could not reliably maintain hanging drops for longer than a few days. With enhanced droplet stability, the hanging drop array plates with micro-ring structures provide better platforms and open up new opportunities for high-throughput preparation of microscale 3D cell constructs for drug screening and cell analysis.

  18. Thermostatic tissue platform for intravital microscopy: 'the hanging drop' model.

    Science.gov (United States)

    Pavlovic, Dragan; Frieling, Helge; Lauer, Kai-Stephan; Bac, Vo Hoai; Richter, Joern; Wendt, Michael; Lehmann, Christian; Usichenko, Taras; Meissner, Konrad; Gruendling, Matthias

    2006-11-01

    Intravital microscopy imposes the particular problem of the combined control of the body temperature of the animal and the local temperature of the observed organ or tissues. We constructed and tested, in the rat ileum microcirculation preparation, a new organ-support platform. The platform consisted of an organ bath filled with physiological solution, and contained a suction tube, a superfusion tube, an intestine-support hand that was attached to a micromanipulator and a thermometer probe. To cover the intestine we used a cover glass plate with a plastic ring glued on its upper surface. After a routine procedure (anaesthesia, monitoring and surgery), the intestine segment (2-3 cm long) was gently exteriorized and placed on the 'hand' of the organ support. A small part of the intestine formed a small 'island' in the bath that was filled with physiological salt solution. The cover glass was secured in place. The physiological salt solution from the superfusion tube, which was pointed to the lower surface of the cover glass, formed a 'hanging drop'. The objective of the microscope was then immersed into distilled water that was formed by the cover glass plastic ring. The 'hanging drop' technique prevented any tissue quenching, ensured undisturbed microcirculation, provided for stable temperature and humidity, and permitted a clear visual field.

  19. Perbandingan Ko-kultur 2D dan 3D dengan Metode Hanging Drop untuk Menghasilkan Micro-environment yang Lebih Relevan Secara Klinis

    Directory of Open Access Journals (Sweden)

    Radiana Dhewayani Antarianto

    2017-09-01

    Full Text Available Ko-kultur sel 2 dimensi (2D kurang menyerupai micro-environment seperti in vivo sedangkan ko-kultur 3 dimensi (3D membentuk mikromassa yang lebih mirip micro-environment in vivo sehingga bermanfaat dalam penelitian biologi dasar. Penelitian ini membandingkan ko-kultur 2D dan 3D sel punca serta sel stelata hepatik dengan metode hanging drop untuk menilai morfologi sel dan pembentukan sferoid dari mikromassa yang terbentuk. Studi in vitro ini dilakukan di Pusat Virologi dan Kanker Patobiologi (PRVKP UI dan laboratorium histologi FKUI pada bulan September 2015 sampai Oktober 2016 menggunakan sel punca yang diisolasi dari darah tali pusat manusia dan sel lestari LX2 (stelata hepatik manusia. Darah tali pusat disortir dengan MACS CD34 dan dianalisis flowcytometry. Ko-kultur sel punca sumsum tulang atau darah tali pusat dan LX2 dilakukan dengan metode hanging drop untuk ko-kultur 2D dan ko-kultur 3D. Triplikasi eksperimen dilakukan untuk tiap set ko-kultur. Hasilnya menunjukkan terdapat perbedaan morfologi ko-kultur 2D dan 3D hanging drop dibandingkan monokultur. Di ko-kultur 2D terdapat mikromassa dan di monokultur 2D tidak terbentuk mikromassa. Di ko-kultur 3D hanging drop, terdapat sferoid yang lebih kecil dibandingkan monokultur 3D hanging drop. Morfologi sel ko-kultur 2D dan 3D dengan metode hanging drop dibandingkan monokultur menunjukkan perubahan fenotip sel-sel yang tergabung dalam mikromassa. Normal 0 false false false false IN X-NONE X-NONE Normal 0 false false false false IN X-NONE X-NONE Effectiveness of mesenchymal stems cells cultured by hanging drop vs. conventional culturing on the repair of hypoxic-ischemic-damaged mouse brains, measured by stemness gene expression

    Directory of Open Access Journals (Sweden)

    Lou Yongli

    2016-01-01

    Full Text Available In this study, we investigated the therapeutic effects of Human Mesenchymal Stem Cells (hMSCs cultured by hanging drop and conventional culturing methods on cerebellar repair in hypoxic-ischemic (HI brain injured mice. Real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR was used to analyze the expression levels of three stemness genes, Oct4, Sox2 and Nanog, and the migration related gene CXCR4. MSC prepared by hanging drop or conventional techniques were administered intranasally to nine day old mice, and analyzed by MRI at day 28. Results indicate that the MSCs, especially the hanging drop cultured MSCs, significantly improved the mice’s cerebellar damage repair. MSCs derived from the hanging drop culture were smaller than those from the conventional culture. The gene expression levels were significantly increased for the MSCs derived from the hanging drop culture. The mechanism might relate to the fact that the hanging drop cultured MSCs can be kept in an undifferentiated state, resulting in its higher expression level of migration receptor of CXCR4.

  1. Transfer, imaging, and analysis plate for facile handling of 384 hanging drop 3D tissue spheroids.

    Science.gov (United States)

    Cavnar, Stephen P; Salomonsson, Emma; Luker, Kathryn E; Luker, Gary D; Takayama, Shuichi

    2014-04-01

    Three-dimensional culture systems bridge the experimental gap between in vivo and in vitro physiology. However, nonstandardized formation and limited downstream adaptability of 3D cultures have hindered mainstream adoption of these systems for biological applications, especially for low- and moderate-throughput assays commonly used in biomedical research. Here we build on our recent development of a 384-well hanging drop plate for spheroid culture to design a complementary spheroid transfer and imaging (TRIM) plate. The low-aspect ratio wells of the TRIM plate facilitated high-fidelity, user-independent, contact-based collection of hanging drop spheroids. Using the TRIM plate, we demonstrated several downstream analyses, including bulk tissue collection for flow cytometry, high-resolution low working-distance immersion imaging, and timely reagent delivery for enzymatic studies. Low working-distance multiphoton imaging revealed a cell type-dependent, macroscopic spheroid structure. Unlike ovarian cancer spheroids, which formed loose, disk-shaped spheroids, human mammary fibroblasts formed tight, spherical, and nutrient-limited spheroids. Beyond the applications we describe here, we expect the hanging drop spheroid plate and complementary TRIM plate to facilitate analyses of spheroids across the spectrum of throughput, particularly for bulk collection of spheroids and high-content imaging.

  2. Study of electrochemical behavior of desatinib using hanging mercury drop electrode and gold disc electrode

    Czech Academy of Sciences Publication Activity Database

    Nováková, Kateřina; Navrátil, Tomáš; Jaklová Dytrtová, Jana; Jakl, M.

    2015-01-01

    Roč. 11, č. 1 (2015), s. 116-116 ISSN 1336-7242 Institutional support: RVO:61388955 ; RVO:61388963 Keywords : electrochemistry * hanging mercury drop electrode * gold electrode Subject RIV: CG - Electrochemistry

  3. Imaging transport phenomena during lysozyme protein crystal growth by the hanging drop technique

    Science.gov (United States)

    Sethia Gupta, Anamika; Gupta, Rajive; Panigrahi, P. K.; Muralidhar, K.

    2013-06-01

    The present study reports the transport process that occurs during the growth of lysozyme protein crystals by the hanging drop technique. A rainbow schlieren technique has been employed for imaging changes in salt concentration. A one dimensional color filter is used to record the deflection of the light beam. An optical microscope and an X-ray crystallography unit are used to characterize the size, tetragonal shape and Bravais lattice constants of the grown crystals. A parametric study on the effect of drop composition, drop size, reservoir height and number of drops on the crystal size and quality is reported. Changes in refractive index are not large enough to create a meaningful schlieren image in the air gap between the drop and the reservoir. However, condensation of fresh water over the reservoir solution creates large changes in the concentration of NaCl, giving rise to clear color patterns in the schlieren images. These have been analyzed to obtain salt concentration profiles near the free surface of the reservoir solution as a function of time. The diffusion of fresh water into the reservoir solution at the early stages of crystal growth followed by the mass flux of salt from the bulk solution towards the free surface has been recorded. The overall crystal growth process can be classified into two regimes, as demarcated by the changes in slope of salt concentration within the reservoir. The salt concentration in the reservoir equilibrates at long times when the crystallization process is complete. Thus, transport processes in the reservoir emerge as the route to monitor protein crystal growth in the hanging drop configuration. Results show that crystal growth rate is faster for a higher lysozyme concentration, smaller drops, and larger reservoir heights.

  4. Voltammetry of Aluminum Nanoparticles in Aqueous Media with Hanging Mercury Drop Electrode

    Czech Academy of Sciences Publication Activity Database

    Korshunov, A.; Heyrovský, Michael

    2010-01-01

    Roč. 22, 17-18 (2010), s. 1989-1993 ISSN 1040-0397. [International Conference on Modern Electroanalytical Methods. Prague, 09.12.2009-14.12.2009] R&D Projects: GA AV ČR IAA400400806 Institutional research plan: CEZ:AV0Z40400503 Keywords : linear cyclic voltammetry * Hanging mercury drop electrode * Aluminum nanoparticles dispersion Subject RIV: CG - Electrochemistry Impact factor: 2.721, year: 2010

  5. Media additives to promote spheroid circularity and compactness in hanging drop platform.

    Science.gov (United States)

    Leung, Brendan M; Lesher-Perez, Sasha Cai; Matsuoka, Toshiki; Moraes, Christopher; Takayama, Shuichi

    2015-02-01

    Three-dimensional spheroid cultures have become increasingly popular as drug screening platforms, especially with the advent of different high throughput spheroid forming technologies. However, comparing drug efficacy across different cell types in spheroid culture can be difficult due to variations in spheroid morphologies and transport characteristics. Improving the reproducibility of compact, circular spheroids contributes to standardizing and increasing the fidelity of the desired gradient profiles in these drug screening three-dimensional tissue cultures. In this study we discuss the role that circularity and compaction has on spheroids, and demonstrate the impact methylcellulose (MethoCel) and collagen additives in the culture media can contribute to more compact and circular spheroid morphology. We demonstrate that improved spheroid formation is not a simple function of increased viscosity of the different macromolecule additives, suggesting that other macromolecular characteristics contribute to improved spheroid formation. Of the various macromolecular additives tested for hanging drop culture, MethoCel provided the most desirable spheroid formation. Additionally, the higher viscosity of MethoCel-containing media improved the ease of imaging of cellular spheroids within hanging drop cultures by reducing motion-induced image blur.

  6. 3D Hanging Drop Culture to Establish Prostate Cancer Organoids.

    Science.gov (United States)

    Eder, Theresa; Eder, Iris E

    2017-01-01

    Three-dimensional (3D) cell culture enables the growth of cells in a multidimensional and multicellular manner compared to conventional cell culture techniques. Especially in prostate cancer research there is a big need for more tissue-recapitulating models to get a better understanding of the mechanisms driving prostate cancer as well as to screen for more efficient drugs that can be used for treatment. In this chapter we describe a 3D hanging drop system that can be used to culture prostate cancer organoids as tumor epithelial monocultures and as epithelial-stromal cocultures.

  7. Comparison of spring-loaded, loss of resistance and hanging drop techniques in lumbar epidural blocks.

    Science.gov (United States)

    Gülen, Güven; Akkaya, Taylan; Ozkan, Derya; Kaydul, Mehmet; Gözaydin, Orhan; Gümüş, Haluk

    2012-01-01

    The spring-loaded syringe is a loss of resistance syringe that provide a more objective sign that the epidural space has been entered compared with the traditional techniques. The aim of this study was to compare the time required to locate the epidural space and the backache incidence with the spring-loaded (SL), loss of resistance (LOR) and the hanging drop (HD) techniques for epidural blocks in patients undergoing transurethral resection procedure. Sixty patients undergoing transurethral resections were enrolled in the study. The patients were randomly assigned to one of three groups. Epidural block was performed in the first group with a spring-loaded syringe (n=20), in the second group with loss-of-resistance syringe (n=20), and in the third group with the hanging drop technique (n=20). The required time to locate the epidural space, the number of attempts, the incidence of dural puncture and the backache incidence were assessed during the procedure and for four weeks after the procedure in all patients. The required time to locate the epidural space was 29.1 ± 9.16 seconds in Group 1; 45.25 ± 19.58 seconds in Group 2, and 47.35 ± 11.42 seconds in Group 3 (p0.05). The use of SL syringe was found to have a shorter time period to locate the epidural space when compared with the LOR syringe and hanging drop technique.

  8. Colony, hanging drop, and methylcellulose three dimensional hypoxic growth optimization of renal cell carcinoma cell lines.

    Science.gov (United States)

    Matak, Damian; Brodaczewska, Klaudia K; Lipiec, Monika; Szymanski, Łukasz; Szczylik, Cezary; Czarnecka, Anna M

    2017-08-01

    Renal cell carcinoma (RCC) is the most lethal of the common urologic malignancies, comprising 3% of all human neoplasms, and the incidence of kidney cancer is rising annually. We need new approaches to target tumor cells that are resistant to current therapies and that give rise to recurrence and treatment failure. In this study, we focused on low oxygen tension and three-dimensional (3D) cell culture incorporation to develop a new RCC growth model. We used the hanging drop and colony formation methods, which are common in 3D culture, as well as a unique methylcellulose (MC) method. For the experiments, we used human primary RCC cell lines, metastatic RCC cell lines, human kidney cancer stem cells, and human healthy epithelial cells. In the hanging drop assay, we verified the potential of various cell lines to create solid aggregates in hypoxic and normoxic conditions. With the semi-soft agar method, we also determined the ability of various cell lines to create colonies under different oxygen conditions. Different cell behavior observed in the MC method versus the hanging drop and colony formation assays suggests that these three assays may be useful to test various cell properties. However, MC seems to be a particularly valuable alternative for 3D cell culture, as its higher efficiency of aggregate formation and serum independency are of interest in different areas of cancer biology.

  9. Enhanced differentiation of human embryonic stem cells into cardiomyocytes by combining hanging drop culture and 5-azacytidine treatment.

    Science.gov (United States)

    Yoon, Byung Sun; Yoo, Seung Jun; Lee, Jeoung Eun; You, Seungkwon; Lee, Hoon Taek; Yoon, Hyun Soo

    2006-04-01

    Cell replacement therapy is a promising approach for the treatment of cardiac diseases. It is, however, challenged by a limited supply of appropriate cells. Therefore, we have investigated whether functional cardiomyocytes can be efficiently generated from human embryonic stem cells (hESCs). In this study, we developed an efficient protocol for the generation of functional cardiomyocytes from hESCs by combining hanging drop culture and 5-azacytidine, a well-known demethylating agent, and then evaluated the expression of cardiac-specific markers. hESCs were cultured both in the medium without or with 0.1, 1, or 10 microM of 5-azacytidine under a hanging drop culture. The expression of several cardiac-specific markers was determined by real-time PCR, RT-PCR, immunofluorescence, and confocal microscopy. To verify the structural and functional properties of hESC-derived cardiomyocytes, we performed electron microscopy and electrophysiological recording. The efficiency of beating cell generation was significantly improved in the hanging drop culture compared with that in suspension culture. Treatment of hESCs with 0.1 microM of 5-azacytidine for 1-3 days significantly increased the number of beating cells and simultaneously enhanced the expression of cardiac-specific markers. Transmission electron microscopy and electrophysiological recording showed that hESC-derived cardiomyocytes acquired structural and functional properties of cardiomyocytes. In conclusion, these results suggest that differentiation of hESCs into cardiomyocytes can be enhanced by the combination of hanging drop culture and 5-azacytidine treatment. Also the methylation status of genes related to cardiomyocyte development may play an important role in the differentiation of hESCs into cardiomyocytes.

  10. Molecular dynamics study of the vaporization of an ionic drop

    Science.gov (United States)

    Galamba, N.

    2010-09-01

    The melting of a microcrystal in vacuum and subsequent vaporization of a drop of NaCl were studied through molecular dynamics simulations with the Born-Mayer-Huggins-Tosi-Fumi rigid-ion effective potential. The vaporization was studied for a single isochor at increasing temperatures until the drop completely vaporized, and gaseous NaCl formed. Examination of the vapor composition shows that the vapor of the ionic drop and gaseous NaCl are composed of neutral species, the most abundant of which, ranging from simple NaCl monomers (ion pairs) to nonlinear polymers, (NanCln)n=2-4. The enthalpies of sublimation, vaporization, and dissociation of the different vapor species are found to be in reasonable agreement with available experimental data. The decrease of the enthalpy of vaporization of the vapor species, with the radius of the drop decrease, accounts for a larger fraction of trimers and tetramers than that inferred from experiments. Further, the rhombic dimer is significantly more abundant than its linear isomer although the latter increases with the temperature. The present results suggest that both trimers and linear dimers may be important to explain the vapor pressure of molten NaCl at temperatures above 1500 K.

  11. Sizing of colloidal particle and protein molecules in a hanging fluid drop

    Science.gov (United States)

    Ansari, Rafat R.; Suh, Kwang I.

    1995-01-01

    We report non-invasive particle size measurements of polystyrene latex colloidal particles and bovine serum albumin (BSA) protein molecules suspended in tiny hanging fluid drops of 30 micro-Liter volume using a newly designed fiber optic probe. The probe is based upon the principles of the technique of dynamic light scattering (DLS). The motivation for this work comes from growing protein crystals in outer space. Protein crystals have been grown previously in hanging drops in microgravity experiments on-board the space shuttle orbiter. However, obtaining quantitative information on nucleation and growth of the protein crystals in real time has always been a desired goal, but hitherto not achieved. Several protein researchers have shown interest in using DLS to monitor crystal growth process in a droplet, but elaborate instrumentation and optical alignment problems have made in-situ applications difficult. We demonstrate that such an experiment is now possible. Our system offers fast (5 seconds) determination of particle size, utilize safe levels of very low laser power (less than or equal to 0.2 mW), a small scattering volume (approximately 2 x 10(exp -5) cu mm) and high spatial coherence (Beta) values. This is a major step forward when compared to currently available DLS systems.

  12. Molecular dynamics study of the vaporization of an ionic drop.

    Science.gov (United States)

    Galamba, N

    2010-09-28

    The melting of a microcrystal in vacuum and subsequent vaporization of a drop of NaCl were studied through molecular dynamics simulations with the Born-Mayer-Huggins-Tosi-Fumi rigid-ion effective potential. The vaporization was studied for a single isochor at increasing temperatures until the drop completely vaporized, and gaseous NaCl formed. Examination of the vapor composition shows that the vapor of the ionic drop and gaseous NaCl are composed of neutral species, the most abundant of which, ranging from simple NaCl monomers (ion pairs) to nonlinear polymers, (Na(n)Cl(n))(n=2-4). The enthalpies of sublimation, vaporization, and dissociation of the different vapor species are found to be in reasonable agreement with available experimental data. The decrease of the enthalpy of vaporization of the vapor species, with the radius of the drop decrease, accounts for a larger fraction of trimers and tetramers than that inferred from experiments. Further, the rhombic dimer is significantly more abundant than its linear isomer although the latter increases with the temperature. The present results suggest that both trimers and linear dimers may be important to explain the vapor pressure of molten NaCl at temperatures above 1500 K.

  13. Redifferentiation of in vitro expanded adult articular chondrocytes by combining the hanging-drop cultivation method with hypoxic environment.

    Science.gov (United States)

    Martinez, Inigo; Elvenes, Jan; Olsen, Randi; Bertheussen, Kjell; Johansen, Oddmund

    2008-01-01

    The main purpose of this work has been to establish a new culturing technique to improve the chondrogenic commitment of isolated adult human chondrocytes, with the aim of being used during cell-based therapies or tissue engineering strategies. By using a rather novel technique to generate scaffold-free three-dimensional (3D) structures from in vitro expanded chondrocytes, we have explored the effects of different culture environments on cartilage formation. Three-dimensional chondrospheroids were developed by applying the hanging-drop technique. Cartilage tissue formation was attempted after combining critical factors such as serum-containing or serum-free media and atmospheric (20%) or low (2.5%) oxygen tensions. The quality of the formed microtissues was analyzed by histology, immunohistochemistry, electron microscopy, and real-time PCR, and directly compared with native adult cartilage. Our results revealed highly organized, 3D tissue-like structures developed by the hanging-drop method. All culture conditions allowed formation of 3D spheroids; however, cartilage generated under low oxygen tension had a bigger size, enhanced matrix deposition, and higher quality of cartilage formation. Real-time PCR demonstrated enhanced expression of cartilage-specific genes such us collagen type II and aggrecan in 3D cultures when compared to monolayers. Cartilage-specific matrix proteins and genes expressed in hanging-drop-developed spheroids were comparable to the expression obtained by applying the pellet culture system. In summary, our results indicate that a combination of 3D cultures of chondrocytes in hanging drops and a low oxygen environment represent an easy and convenient way to generate cartilage-like microstructures. We also show that a new specially tailored serum-free medium is suitable for in vitro cartilage tissue formation. This new methodology opens up the possibility of using autogenously produced solid 3D structures with redifferentiated chondrocytes as an

  14. Determination of trace arsenic on hanging copper amalgam drop electrode.

    Science.gov (United States)

    Piech, Robert; Baś, Bogusław; Niewiara, Ewa; Kubiak, Władysław W

    2007-04-30

    Hanging copper amalgam drop electrode has been applied for trace determination of arsenic by cathodic stripping analysis. Detection limit for As(III) as low as 0.33nM (0.02mug/L) at deposition time (240s) could be obtained. For seven successive determinations of As(III) at concentration of 5nM relative standard deviation was 2.5% (n=7). Interferences from selected metals and surfactant substances were examined. Absence of copper ions in sample solution causes easier optimization and makes method less vulnerable on contamination. The developed method was validated by analysis of certified reference materials (CRMs) and applied to arsenic determinations in natural water samples.

  15. Increased sensitivity of anodic stripping voltammetry at the hanging mercury drop electrode by ultracathodic deposition.

    Science.gov (United States)

    Rodrigues, José A; Rodrigues, Carlos M; Almeida, Paulo J; Valente, Inês M; Gonçalves, Luís M; Compton, Richard G; Barros, Aquiles A

    2011-09-09

    An improved approach to the anodic stripping voltammetric (ASV) determination of heavy metals, using the hanging mercury drop electrode (HMDE), is reported. It was discovered that using very cathodic accumulation potentials, at which the solvent reduction occurs (overpotential deposition), the voltammetric signals of zinc(II), cadmium(II), lead(II) and copper(II) increase. When compared with the classical methodology a 5 to 10-fold signal increase is obtained. This effect is likely due to both mercury drop oscillation at such cathodic potentials and added local convection at the mercury drop surface caused by the evolution of hydrogen bubbles. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Intracellular localization of pregnane X receptor in HepG2 cells cultured by the hanging drop method.

    Science.gov (United States)

    Yokobori, Kosuke; Kobayashi, Kaoru; Azuma, Ikuko; Akita, Hidetaka; Chiba, Kan

    2017-10-01

    Pregnane X receptor (PXR) is localized in the cytoplasm of liver cells, whereas it is localized in the nucleus of monolayer-cultured HepG2 cells. Since cultured cells are affected by the microenvironment in which they are grown, we studied the effect of three-dimensional (3D) culture on the localization of PXR in HepG2 cells using the hanging drop method. The results showed that PXR was retained in the cytoplasm of HepG2 cells and other human hepatocarcinoma cell lines (FLC5, FLC7 and Huh7) when they were cultured by the hanging drop method. Treatment with rifampicin, a ligand of PXR, translocated PXR from the cytoplasm to nucleus and increased expression levels of CYP3A4 mRNA in HepG2 cells cultured by the hanging drop method. These findings suggest that 3D culture is a key factor determining the intracellular localization of PXR in human hepatocarcinoma cells and that PXR that becomes retained in the cytoplasm of HepG2 cells with 3D culture has functions of nuclear translocation and regulation of target genes in response to human PXR ligands. Three-dimensionally cultured hepatocarcinoma cells would be a useful tool to evaluate induction potency of drug candidates and also to study mechanisms of nuclear translocation of PXR by human PXR ligands. Copyright © 2017 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.

  17. Human HepaRG Cells can be Cultured in Hanging-drop Plates for Cytochrome P450 Induction and Function Assays.

    Science.gov (United States)

    Murayama, Norie; Usui, Takashi; Slawny, Nicky; Chesné, Christophe; Yamazaki, Hiroshi

    2015-01-01

    Recent guidance/guidelines for industry recommend that cytochrome P450 induction can be assessed using human hepatocyte enzyme activity and/or mRNA levels to evaluate potential drug- drug interactions. To evaluate time-dependent cytochrome P450 induction precisely, induction of CYP1A2, CYP2B6, and CYP3A4 mRNA was confirmed (>2-fold) by the treatment with omeprazole, phenobarbital, and rifampicin, respectively, for 24 or 48 h on day 3 from the start of culture. After 24 h, the fold induction of CYP1A2 with 3.6 and 1.8x10(4) HepaRG cells per well was lower than that for 7.2x10(4) cells. CYP1A2 induction levels at 24 h were higher than those after 48 h. In contrast, higher CYP2B6 inductions were confirmed after 48 h exposure than after 24 h, independent of the number of cells per well. To help reduce the use of human cryopreserved hepatocytes, typical P450-dependent enzyme activities were investigated in human HepaRG cells cultured in commercial hanging-drop plates. Newly designed 96-well hanging-drop plates were capable of maintaining human CYP3A-dependent midazolam hydroxylation activities for up to 4 days using only 10% of the recommended initial 7.2x10(4) cells per well. Favorable HepaRG function using hanging-drop plates was confirmed by detecting 1'- hydroxymidazolam O-glucuronide on day 3, suggesting an improvement over traditional control plates in which this metabolite can be detected for 24-well plates. These results suggest that the catalytic function and/or induction of CYP1A2, CYP2B6, and CYP3A4 can be readily assessed with reduced numbers of starting HepaRG cells cultured in three-dimensional cultures in drops prepared with hanging-drop plates.

  18. High-throughput 3D spheroid culture and drug testing using a 384 hanging drop array.

    Science.gov (United States)

    Tung, Yi-Chung; Hsiao, Amy Y; Allen, Steven G; Torisawa, Yu-suke; Ho, Mitchell; Takayama, Shuichi

    2011-02-07

    Culture of cells as three-dimensional (3D) aggregates can enhance in vitro tests for basic biological research as well as for therapeutics development. Such 3D culture models, however, are often more complicated, cumbersome, and expensive than two-dimensional (2D) cultures. This paper describes a 384-well format hanging drop culture plate that makes spheroid formation, culture, and subsequent drug testing on the obtained 3D cellular constructs as straightforward to perform and adapt to existing high-throughput screening (HTS) instruments as conventional 2D cultures. Using this platform, we show that drugs with different modes of action produce distinct responses in the physiological 3D cell spheroids compared to conventional 2D cell monolayers. Specifically, the anticancer drug 5-fluorouracil (5-FU) has higher anti-proliferative effects on 2D cultures whereas the hypoxia activated drug commonly referred to as tirapazamine (TPZ) are more effective against 3D cultures. The multiplexed 3D hanging drop culture and testing plate provides an efficient way to obtain biological insights that are often lost in 2D platforms.

  19. Energy stability of droplets and dry spots in a thin film model of hanging drops

    Science.gov (United States)

    Cheung, Ka-Luen; Chou, Kai-Seng

    2017-10-01

    The 2-D thin film equation describing the evolution of hang drops is studied. All radially symmetric steady states are classified, and their energy stability is determined. It is shown that the droplet with zero contact angle is the only global energy minimizer and the dry spot with zero contact angle is a strict local energy minimizer.

  20. Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Mi Jin; Shin, Yeon Jae; Oh, Se Yeon; Kim, Nam Sun; Kim, Kun; Lee, Dong Sun [Seoul Women' s University, Seoul (Korea, Republic of)

    2006-02-15

    A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 μL. 60 min extraction time at 25 .deg. C was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant (K{sub lh}) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, β-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.

  1. Generation of multicellular tumor spheroids by the hanging-drop method.

    Science.gov (United States)

    Timmins, Nicholas E; Nielsen, Lars K

    2007-01-01

    Owing to their in vivo-like characteristics, three-dimensional (3D) multicellular tumor spheroid (MCTS) cultures are gaining increasing popularity as an in vitro model of tumors. A straightforward and simple approach to the cultivation of these MCTS is the hanging-drop method. Cells are suspended in droplets of medium, where they develop into coherent 3D aggregates and are readily accessed for analysis. In addition to being simple, the method eliminates surface interactions with an underlying substratum (e.g., polystyrene plastic or agarose), requires only a low number of starting cells, and is highly reproducible. This method has also been applied to the co-cultivation of mixed cell populations, including the co-cultivation of endothelial cells and tumor cells as a model of early tumor angiogenesis.

  2. Vortex-Induced Vapor Explosion during Drop Impact on a Superheated Pool

    KAUST Repository

    Alchalabi, M.A.

    2017-04-18

    Ultra high-speed imaging is used to investigate the vapor explosion when a drop impacts onto a high-temperature pool. The two liquids are immiscible, a low boiling-temperature perfluorohexane drop, at room temperature, which impacts a high boiling-temperature soybean-oil pool, which is heated well above the boiling temperature of the drop. We observe different regimes: weak and strong nucleate boiling, film boiling or Leidenfrost regime and entrainment followed by vapor explosion. The vapor explosions were seen to depend on the formation of a rotational flow at the edge of the impact crater, near the pool surface, which resembles a vortex ring. This rotational motion entrains a thin sheet of the drop liquid, to become surrounded by the oil. In that region, the vapor explosion starts at a point after which it propagates azimuthally along the entire periphery at high speed.

  3. Vortex-Induced Vapor Explosion during Drop Impact on a Superheated Pool

    KAUST Repository

    Alchalabi, M.A.; Kouraytem, Nadia; Li, Erqiang; Thoroddsen, Sigurdur T

    2017-01-01

    Ultra high-speed imaging is used to investigate the vapor explosion when a drop impacts onto a high-temperature pool. The two liquids are immiscible, a low boiling-temperature perfluorohexane drop, at room temperature, which impacts a high boiling-temperature soybean-oil pool, which is heated well above the boiling temperature of the drop. We observe different regimes: weak and strong nucleate boiling, film boiling or Leidenfrost regime and entrainment followed by vapor explosion. The vapor explosions were seen to depend on the formation of a rotational flow at the edge of the impact crater, near the pool surface, which resembles a vortex ring. This rotational motion entrains a thin sheet of the drop liquid, to become surrounded by the oil. In that region, the vapor explosion starts at a point after which it propagates azimuthally along the entire periphery at high speed.

  4. Cervical spine injuries in suicidal hanging without a long-drop--patterns and possible underlying mechanisms of injury: an autopsy study.

    Science.gov (United States)

    Nikolić, Slobodan; Zivković, Vladimir

    2014-06-01

    The incidence of cervical spine injuries in suicidal hangings with a short-drop has been reported to be extremely low or non-existent. The aim of this study was to determine the frequency and pattern of cervical spine injuries in suicidal hanging. A retrospective autopsy study was performed and short-drop suicidal hanging cases with documented cervical spine injuries were identified. This group was further analyzed with regard to the gender and age of the deceased, the position of the ligature knot, the presence of hyoid-laryngeal fractures, and the level of cervical spine injury. Cervical spine injuries were present in 25 of the 766 cases, with an average age of 71.9 ± 10.7 years (range 39-88 years). In 16 of these 25 cases, the ligature knot was in the anterior position. The most common pattern of cervical spine injury included partial or complete disruption of the anterior longitudinal ligament and widening of the lower cervical spine disk spaces, associated with absence of hyoid-laryngeal fractures. Cervical spine injuries are not commonly found in short-drop suicidal hanging, occurring in only 3.3 % of all observed cases. Cervical spine injury may be occurring in 80 % of subjects aged 66.5 years and above. The most common pattern of cervical spine injury included anterior longitudinal ligament disruption of the lower cervical spine, disk space widening, and no vertebral body displacement. These injuries were mainly associated with an anterior knot position, and may be a consequence of loop pressure to the posterior neck and cervical spine hyperextension.

  5. Increased sensitivity of anodic stripping voltammetry at the hanging mercury drop electrode by ultracathodic deposition

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Jose A.; Rodrigues, Carlos M.; Almeida, Paulo J.; Valente, Ines M.; Goncalves, Luis M. [Requimte - Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade do Porto, Rua do Campo Alegre, no. 687, 4169-007 Porto (Portugal); Compton, Richard G. [Department of Chemistry, Physical and Theoretical Chemistry Laboratory, Oxford University, South Parks Road, Oxford OX1 3QZ (United Kingdom); Barros, Aquiles A., E-mail: ajbarros@fc.up.pt [Requimte - Departamento de Quimica e Bioquimica, Faculdade de Ciencias, Universidade do Porto, Rua do Campo Alegre, no. 687, 4169-007 Porto (Portugal)

    2011-09-09

    Highlights: {yields} At very cathodic accumulation potentials (overpotential deposition) the voltammetric signals of Zn{sup 2+}, Cd{sup 2+}, Pb{sup 2+} and Cu{sup 2+} increase. {yields} 5 to 10-fold signal increase is obtained. {yields} This effect is likely due to mercury drop oscillation at such cathodic potentials. {yields} This effect is also likely due to added local convection at the mercury drop surface caused by the evolution of hydrogen bubbles. - Abstract: An improved approach to the anodic stripping voltammetric (ASV) determination of heavy metals, using the hanging mercury drop electrode (HMDE), is reported. It was discovered that using very cathodic accumulation potentials, at which the solvent reduction occurs (overpotential deposition), the voltammetric signals of zinc(II), cadmium(II), lead(II) and copper(II) increase. When compared with the classical methodology a 5 to 10-fold signal increase is obtained. This effect is likely due to both mercury drop oscillation at such cathodic potentials and added local convection at the mercury drop surface caused by the evolution of hydrogen bubbles.

  6. Effectiveness of mesenchymal stems cells cultured by hanging drop vs. conventional culturing on the repair of hypoxic-ischemic-damaged mouse brains, measured by stemness gene expression

    OpenAIRE

    Lou Yongli; Guo Dewei; Zhang Hui; Song Laijun

    2016-01-01

    In this study, we investigated the therapeutic effects of Human Mesenchymal Stem Cells (hMSCs) cultured by hanging drop and conventional culturing methods on cerebellar repair in hypoxic-ischemic (HI) brain injured mice. Real-time quantitative reverse transcription polymerase chain reaction (RT-qPCR) was used to analyze the expression levels of three stemness genes, Oct4, Sox2 and Nanog, and the migration related gene CXCR4. MSC prepared by hanging drop or conventional techniques were adminis...

  7. Optimal formation of genetically modified and functional pancreatic islet spheroids by using hanging-drop strategy.

    Science.gov (United States)

    Kim, H J; Alam, Z; Hwang, J W; Hwang, Y H; Kim, M J; Yoon, S; Byun, Y; Lee, D Y

    2013-03-01

    Rejection and hypoxia are important factors causing islet loss at an early stage after pancreatic islet transplantation. Recently, islets have been dissociated into single cells for reaggregation into so-called islet spheroids. Herein, we used a hanging-drop strategy to form islet spheroids to achieve functional equivalence to intact islets. To obtain single islet cells, we dissociated islets with trypsin-EDTA digestion for 10 minutes. To obtain spheroids, we dropped various numbers of single cells (125, 250, or 500 cells/30 μL drop) onto a Petri dish, that was inverted for incubation in humidified air containing 5% CO(2) at 37 °C for 7 days. The aggregated spheroids in the droplets were harvested for further culture. The size of the aggregated islet spheroids depended on the number of single cells (125-500 cells/30 μL droplet). Their morphology was similar to that of intact islets without any cellular damage. When treated with various concentrations of glucose to evaluate responsiveness, their glucose-mediated stimulation index value was similar to that of intact islets, an observation that was attributed to strong cell-to-cell interactions in islet spheroids. However, islet spheroids aggregated in general culture dishes showed abnormal glucose responsiveness owing to weak cell-to-cell interactions. Cell-to-cell interactions in islet spheroids were confirmed with an anti-connexin-36 monoclonal antibody. Finally, nonviral poly(ethylene imine)-mediated interleukin-10 cytokine gene delivered beforehand into dissociated single cells before formation of islet spheroids increased the gene transfection efficacy and interleukin-10 secretion from islet spheroids >4-fold compared with intact islets. These results demonstrated the potential application of genetically modified, functional islet spheroids with of controlled size and morphology using an hanging-drop technique. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Seamless Combination of Fluorescence-Activated Cell Sorting and Hanging-Drop Networks for Individual Handling and Culturing of Stem Cells and Microtissue Spheroids.

    Science.gov (United States)

    Birchler, Axel; Berger, Mischa; Jäggin, Verena; Lopes, Telma; Etzrodt, Martin; Misun, Patrick Mark; Pena-Francesch, Maria; Schroeder, Timm; Hierlemann, Andreas; Frey, Olivier

    2016-01-19

    Open microfluidic cell culturing devices offer new possibilities to simplify loading, culturing, and harvesting of individual cells or microtissues due to the fact that liquids and cells/microtissues are directly accessible. We present a complete workflow for microfluidic handling and culturing of individual cells and microtissue spheroids, which is based on the hanging-drop network concept: The open microfluidic devices are seamlessly combined with fluorescence-activated cell sorting (FACS), so that individual cells, including stem cells, can be directly sorted into specified culturing compartments in a fully automated way and at high accuracy. Moreover, already assembled microtissue spheroids can be loaded into the microfluidic structures by using a conventional pipet. Cell and microtissue culturing is then performed in hanging drops under controlled perfusion. On-chip drop size control measures were applied to stabilize the system. Cells and microtissue spheroids can be retrieved from the chip by using a parallelized transfer method. The presented methodology holds great promise for combinatorial screening of stem-cell and multicellular-spheroid cultures.

  9. Voltammetric Determination of Carcinogenic Nitrobiphenyls at a Hanging Mercury Drop Electrode

    Directory of Open Access Journals (Sweden)

    Jiří Zima

    2003-02-01

    Full Text Available Differential pulse voltammetry (DPV and adsorptive stripping voltammetry (AdSV at a hanging mercury drop electrode (HMDE was used for the determination of trace amounts of carcinogenic nitrobiphenyls, namely 2-nitrobiphenyl (2-NBP, 3-nitrobiphenyl (3-NBP and 4-nitrobiphenyl (4-NBP within the concentration range from 2.10-8 to 1.10-5 mol⋅L-1 for DPV and from 2.10-9 to 1.10-7 mol⋅L-1 for AdSV using a Britton-Robinson buffer – methanol (1:1 mixture with resulting pH 12 as a base electrolyte. The practical applicability of newly developed methods was verified using model samples of drinking and river water and liquid-liquid extraction for a preliminary separation and preconcentration.

  10. Hanging Drop, A Best Three-Dimensional (3D) Culture Method for Primary Buffalo and Sheep Hepatocytes.

    Science.gov (United States)

    Shri, Meena; Agrawal, Himanshu; Rani, Payal; Singh, Dheer; Onteru, Suneel Kumar

    2017-04-26

    Livestock, having close resemblance to humans, could be a better source of primary hepatocytes than rodents. Herein, we successfully developed three-dimensional (3D) culturing system for primary sheep and buffalo hepatocytes. The 3D-structures of sheep hepatocytes were formed on the fifth-day and maintained until the tenth-day on polyHEMA-coated plates and in hanging drops with William's E media (HDW). Between the cultured and fresh cells, we observed a similar expression of GAPDH, HNF4α, ALB, CYP1A1, CK8 and CK18. Interestingly, a statistically significant increase was noted in the TAT, CPS, AFP, AAT, GSP and PCNA expression. In buffalo hepatocytes culture, 3D-like structures were formed on the third-day and maintained until the sixth-day on polyHEMA and HDW. The expression of HNF4α, GSP, CPS, AFP, AAT, PCNA and CK18 was similar between cultured and fresh cells. Further, a statistically significant increase in the TAT and CK8 expression, and a decrease in the GAPDH, CYP1A1 and ALB expression were noted. Among the culture systems, HDW maintained the liver transcript markers more or less similar to the fresh hepatocytes of the sheep and buffalo for ten and six days, respectively. Taken together, hanging drop is an efficient method for 3D culturing of primary sheep and buffalo hepatocytes.

  11. Mouse ES cells have a potential to differentiate into odontoblast-like cells using hanging drop method.

    Science.gov (United States)

    Kawai, R; Ozeki, N; Yamaguchi, H; Tanaka, T; Nakata, K; Mogi, M; Nakamura, H

    2014-05-01

    We examined whether mouse embryonic stem (ES) cells can differentiate into odontoblast-like cells without epithelial-mesenchymal interaction. Cells were cultured by the 'hanging drop' method using a collagen type-I scaffold (CS) combined with bone morphogenetic protein (BMP)-4 (CS/BMP-4). Expression of odontoblast-related mRNA and protein, and cell proliferation were performed by reverse transcription-polymerase chain reaction (RT-PCR), immunofluorescence staining and WST-1 assay, respectively. Cells potently expressed odontoblast-related cell marker mRNAs following induction of odontoblastic differentiation. Dentin sialophosphoprotein, a marker of mature odontoblasts, was strongly expressed in differentiated ES cells. The cells also acquired an odontoblast-like functional phenotype, as evidenced by the appearance of alkaline phosphatase activity and calcification. The cell-surface expression of α2, α6, αV and αVβ3 integrin proteins was rapidly upregulated in differentiated cells. Finally, anti-α2 integrin antibody suppressed the expression of odontoblastic markers in cells grown using this culture system, suggesting that α2 integrin expression in ES cells triggers their differentiation into odontoblast-like cells. Mouse ES cells cultured by the 'hanging drop' method are able to differentiate into cells with odontoblast-specific physiological functions and cell-surface integrin protein expression. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Growth factors mediated differentiation of mesenchymal stem cells to cardiac polymicrotissue using hanging drop and bioreactor.

    Science.gov (United States)

    Konstantinou, Dimitrios; Lei, Ming; Xia, Zhidao; Kanamarlapudi, Venkateswarlu

    2015-04-01

    Heart disease is the major leading cause of death worldwide and the use of stem cells promises new ways for its treatment. The relatively easy and quick acquisition of human umbilical cord matrix mesenchymal stem cells (HUMSCs) and their properties make them useful for the treatment of cardiac diseases. Therefore, the main aim of this investigation was to create cardiac polymicrotissue from HUMSCs using a combination of growth factors [sphingosine-1-phosphate (S1P) and suramin] and techniques (hanging drop and bioreactor). Using designated culture conditions of the growth factors (100 nM S1P and 500 µM suramin), cardiomyocyte differentiation medium (CDM), hanging drop, bioreactor and differentiation for 7 days, a potential specific cardiac polymicrotissue was derived from HUMSCs. The effectiveness of growth factors alone or in combination in differentiation of HUMSCs to cardiac polymicrotissue was analysed by assessing the presence of cardiac markers by immunocytochemistry. This analysis demonstrated the importance of those growth factors for the differentiation. This study for the first time demonstrated the formation of a cardiac polymicrotissue under specific culture conditions. The polymicrotissue thus obtained may be used in future as a 'patch' to cover the injured cardiac region and would thereby be useful for the treatment of heart diseases. © 2014 International Federation for Cell Biology.

  13. A hollow sphere soft lithography approach for long-term hanging drop methods.

    Science.gov (United States)

    Lee, Won Gu; Ortmann, Daniel; Hancock, Matthew J; Bae, Hojae; Khademhosseini, Ali

    2010-04-01

    In conventional hanging drop (HD) methods, embryonic stem cell aggregates or embryoid bodies (EBs) are often maintained in small inverted droplets. Gravity limits the volumes of these droplets to less than 50 microL, and hence such cell cultures can only be sustained for a few days without frequent media changes. Here we present a new approach to performing long-term HD methods (10-15 days) that can provide larger media reservoirs in a HD format to maintain more consistent culture media conditions. To implement this approach, we fabricated hollow sphere (HS) structures by injecting liquid drops into noncured poly(dimethylsiloxane) mixtures. These structures served as cell culture chambers with large media volumes (500 microL in each sphere) where EBs could grow without media depletion. The results showed that the sizes of the EBs cultured in the HS structures in a long-term HD format were approximately twice those of conventional HD methods after 10 days in culture. Further, HS cultures showed multilineage differentiation, similar to EBs cultured in the HD method. Due to its ease of fabrication and enhanced features, this approach may be of potential benefit as a stem cell culture method for regenerative medicine.

  14. Water collection behavior and hanging ability of bioinspired fiber.

    Science.gov (United States)

    Hou, Yongping; Chen, Yuan; Xue, Yan; Zheng, Yongmei; Jiang, Lei

    2012-03-13

    Since the water-collecting ability of the wetted cribellate spider capture silk is the result of a unique fiber structure, bioinspired fibers have been researched significantly so as to expose a new water-acquiring route in fogging-collection projects. However, the design of the geometry of bioinspired fiber is related to the ability of hanging drops, which has not been investigated in depth so far. Here, we fabricate bioinspired fibers to investigate the water collection behavior and the influence of geometry (i.e., periodicity of spindle knot) on the hanging-drop ability. We especially discuss water collection related to the periodicity of geometry on the bioinspired fiber. We reveal the length of the three phase contact line (TCL) at threshold conditions in conjunction with the maximal volume of a hanging drop at different modes. The study demonstrates that the geometrical structure of bioinspired fiber induces much stronger water hanging ability than that of uniform fiber, attributed to such special geometry that offers effectively an increasing TCL length or limits the contact length to be shorted. In addition, the geometry also improves the fog-collection efficiency by controlling tiny water drops to be collected in the large water drops at a given location.

  15. Determination of nitrobenzene in wastewater using a hanging mercury drop electrode.

    Science.gov (United States)

    Liang, Shu-Xuan; Zhang, Huan-Kun; Lu, Da

    2007-06-01

    The determination of trace amount nitrobenzene in wastewater on a hanging mercury drop electrode was studied. The determination conditions of pH, supporting electrolyte, accumulation potential, accumulation time, and voltammetric response were optimized. The sharp peak of the nitrobenzene was appeared at 0.05 V. The peak electric current was proportional to the concentration of nitrobenzene in the range of 1.47 x 10(-5) approximately 1.0 x 10(-3) mol/l with relative standard deviations of 3.99 approximately 8.94%. The detection limit of the nitrobenzene in water was 5 x 10(-6) mol/l. The proposed method offered low limit of determination, easy operation, the use of simple instrumentation, high sensitivity and good reproducibility. It was applied to the determination of nitrobenzene in wastewater with an average recovery of 94.0% approximately 105%. The proposed method provided fast, sensitive and sometimes real time detection of nitrobenzene.

  16. The effect of body position on the 'hanging drop' method for identifying the extradural space in anaesthetized dogs.

    Science.gov (United States)

    Naganobu, Kiyokazu; Hagio, Mitsuyoshi

    2007-01-01

    To assess the accuracy of the 'hanging drop method' for identifying the extradural space in anaesthetized dogs positioned in sternal or lateral recumbency. Prospective randomized-experimental study. Seventeen clinically healthy adult dogs, 10 females and seven males weighing 8.4-26.2 kg. Dogs were positioned in either sternal (n = 8) or lateral (n = 9) recumbency under general anaesthesia. A 20 SWG spinal needle pre-filled with 0.9% saline was advanced through the skin into the lumbosacral extradural space and the response of the saline drop recorded, i.e. whether it: 1) was aspirated from the hub into the needle; 2) remained within the hub, or 3) moved synchronously with i) spontaneous respiration, ii) heart beat or iii) manual lung inflation. The position of the needle tip was ultimately determined by positive contrast radiography. One dog positioned in lateral recumbency was excluded from the study because bleeding occurred from the needle hub. Saline was aspirated into the needle in seven of eight dogs held in sternal recumbency but in none of the dogs positioned in lateral recumbency. Accurate needle tip placement in the extradural space was confirmed by positive contrast radiography in all dogs. The 'hanging drop' method, when performed with a spinal needle, appears to be a useful technique for identifying the location of the extradural space in anaesthetized medium-sized dogs positioned in sternal, but not in lateral recumbency. The technique may yield 'false negative' results when performed in dogs positioned in sternal recumbency.

  17. Hanging drop culture enhances differentiation of human adipose-derived stem cells into anterior neuroectodermal cells using small molecules.

    Science.gov (United States)

    Amirpour, Noushin; Razavi, Shahnaz; Esfandiari, Ebrahim; Hashemibeni, Batoul; Kazemi, Mohammad; Salehi, Hossein

    2017-06-01

    Inspired by in vivo developmental process, several studies were conducted to design a protocol for differentiating of mesenchymal stem cells into neural cells in vitro. Human adipose-derived stem cells (hADSCs) as mesenchymal stem cells are a promising source for this purpose. At current study, we applied a defined neural induction medium by using small molecules for direct differentiation of hADSCs into anterior neuroectodermal cells. Anterior neuroectodermal differentiation of hADSCs was performed by hanging drop and monolayer protocols. At these methods, three small molecules were used to suppress the BMP, Nodal, and Wnt signaling pathways in order to obtain anterior neuroectodermal (eye field) cells from hADSCs. After two and three weeks of induction, the differentiated cells with neural morphology expressed anterior neuroectodermal markers such as OTX2, SIX3, β-TUB III and PAX6. The protein expression of such markers was confirmed by real time, RT-PCR and immunocytochemistry methods According to our data, it seems that the hanging drop method is a proper approach for neuroectodermal induction of hADSCs. Considering wide availability and immunosuppressive properties of hADSCs, these cells may open a way for autologous cell therapy of neurodegenerative disorders. Copyright © 2017 ISDN. Published by Elsevier Ltd. All rights reserved.

  18. Comparison of the hanging-drop technique and running-drip method for identifying the epidural space in dogs.

    Science.gov (United States)

    Martinez-Taboada, Fernando; Redondo, José I

    2017-03-01

    To compare the running-drip and hanging-drop techniques for locating the epidural space in dogs. Prospective, randomized, clinical trial. Forty-five healthy dogs requiring epidural anaesthesia. Dogs were randomized into four groups and administered epidural anaesthesia in sternal (S) or lateral (L) recumbency. All blocks were performed by the same person using Tuohy needles with either a fluid-prefilled hub (HDo) or connected to a drip set attached to a fluid bag elevated 60 cm (RDi). The number of attempts, 'pop' sensation, clear drop aspiration or fluid dripping, time to locate the epidural space (TTLES) and presence of cerebrospinal fluid (CSF) were recorded. A morphine-bupivacaine combination was injected after positive identification. The success of the block was assessed by experienced observers based on perioperative usage of rescue analgesia. Data were checked for normality. Binomial variables were analysed with the chi-squared or Fisher's exact test as appropriate. Non-parametric data were analysed using Kruskal-Wallis and Mann-Whitney tests. Normal data were studied with an anova followed by a Tukey's means comparison for groups of the same size. A p-value of Drop aspiration was observed more often in SHDo (nine of 11 dogs) than in LHDo (two of 11 dogs) (p = 0.045). Mean (range) TTLES was longer in LHDo [47 (18-82) seconds] than in SHDo [20 (14-79) seconds] (p = 0.006) and SRDi [(34 (17-53) seconds] (p = 0.038). There were no differences in 'pop' sensation, presence of CSF, rescue analgesia or pain scores between the groups. The running-drip method is a useful and fast alternative technique for identifying the epidural space in dogs. The hanging-drop technique in lateral recumbency was more difficult to perform than the other methods, requiring more time and attempts. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  19. Enrichment of cardiac differentiation of mouse embryonic stem cells by optimizing the hanging drop method.

    Science.gov (United States)

    Chen, Ming; Lin, Yong-Qing; Xie, Shuang-Lun; Wu, Hong-Fu; Wang, Jing-Feng

    2011-04-01

    Hanging drop (HD) culture is used to induce differentiation of embryonic stem cells (ESCs) into other cell types including cardiomyocytes. However, the factors affecting cardiac differentiation of ESCs with this method remain incompletely understood. We have investigated the effects of the starting number of ESCs in embryoid bodies (EBs) and the time of EB adherence to gelatin-coated plates on cardiac differentiation: cardiac differentiation was increased in the EBs by a larger number of ESCs and was decreased by plating EBs at day 4 or earlier. These two factors can thus be optimized to enrich the cardiac differentiation in ESCs using the HD method.

  20. Rat pancreatic islet size standardization by the "hanging drop" technique.

    Science.gov (United States)

    Cavallari, G; Zuellig, R A; Lehmann, R; Weber, M; Moritz, W

    2007-01-01

    Rejection and hypoxia are the main factors that limit islet engraftment in the recipient liver in the immediate posttransplant period. Recently authors have reported a negative relationship of graft function and islet size, concluding that small islets are superior to large islets. Islets can be dissociated into single cells and reaggregated into so called "pseudoislets," which are functionally equivalent to intact islets but exhibit reduced immunogenicity. The aim of our study was develop a technique that enabled one to obtain pseudoislets of defined, preferably small, dimensions. Islets were harvested from Lewis rats by the collagenase digestion procedure. After purification, the isolated islets were dissociated into single cells by trypsin digestion. Fractions with different cell numbers were seeded into single drops onto cell culture dishes, which were inverted and incubated for 5 to 8 days under cell culture conditions. Newly formed pseudoislets were analyzed for dimension, morphology, and cellular composition. The volume of reaggregated pseudoislets strongly correlated with the cell number (r(2) = .995). The average diameter of a 250-cell aggregate was 95 +/- 8 microm (mean +/- SD) compared with 122 +/- 46 microm of freshly isolated islets. Islet cell loss may be minimized by performing reaggregation in the presence of medium glucose (11 mmol/L) and the GLP-1 analogue Exendin-4. Morphology, cellular composition, and architecture of reaggregated islets were comparable to intact islets. The "hanging drop" culture method allowed us to obtain pseudoislets of standardized size and regular shape, which did not differ from intact islets in terms of cellular composition or architecture. Further investigations are required to minimize cell loss and test in vivo function of transplanted pseudoislets.

  1. Voltammetric analysis of N-containing drugs using the hanging galinstan drop electrode (HGDE).

    Science.gov (United States)

    Channaa, H; Surmann, P

    2009-03-01

    The electrochemical behaviour of several N-containing voltammetric active drugs such as 1,4-benzodiazepines (chlordiazepoxide, nitrazepam and diazepam) as well as one nitro-compound (nitrofurantoin) and one azo-compound (phenazopyridine) is described using a new kind of liquid electrode, the hanging galinstan drop electrode. Concentrations of 10(-5) - 10(-8) mol L(-1) are generally measurable. Differential pulse and adsorptive stripping voltammograms are recorded in different supporting electrolytes, like 0.1 M KNO3, acetate buffer solution pH = 4.6 and phosphate buffer solution pH = 7.0. The effects of varying the starting potentials, U(start) for DPV and accumulation times, t(acc) for AdSV are considered. Briefly, it is shown that the novel galinstan electrode is suitable for reducing several functional groups in organic substances, here presented for N-oxide-, azomethine-, nitro- and azo-groups.

  2. Etiology and use of the "hanging drop" technique: a review.

    Science.gov (United States)

    Todorov, Ludmil; VadeBoncouer, Timothy

    2014-01-01

    Background. The hanging drop (HD) technique presumably relies on the presence of subatmospheric epidural pressure. It is not clear whether this negative pressure is intrinsic or an artifact and how it is affected by body position. There are few data to indicate how often HD is currently being used. Methods. We identified studies that measured subatmospheric pressures and looked at the effect of the sitting position. We also looked at the technique used for cervical and thoracic epidural anesthesia in the last 10 years. Results. Intrinsic subatmospheric pressures were measured in the thoracic and cervical spine. Three trials studied the effect of body position, indicating a higher incidence of subatmospheric pressures when sitting. The results show lower epidural pressure (-10.7 mmHg) with the sitting position. 28.8% of trials of cervical and thoracic epidural anesthesia that documented the technique used, utilized the HD technique. When adjusting for possible bias, the rate of HD use can be as low as 11.7%. Conclusions. Intrinsic negative pressure might be present in the cervical and thoracic epidural space. This effect is more pronounced when sitting. This position might be preferable when using HD. Future studies are needed to compare it with the loss of resistance technique.

  3. Voltammetric behavior of amfepramone (diethylpropion) at the hanging mercury drop electrode and its analytical determination in pharmaceutical formulations

    OpenAIRE

    Carvalho, Leandro M. de; Nascimento, Paulo C. do; Bohrer, Denise; Correia, Daniele; Bairros, André V. de; Pomblum, Valdeci J.; Pomblum, Solange G.

    2007-01-01

    This paper describes a systematic study of the voltammetric behavior of amfepramone at the hanging mercury drop electrode (HMDE) by cyclic (CV) and alternating current (AC) voltammetric methods. The studies showed the adsorptive behavior of amfepramone at the HMDE and were performed in H2SO4 0.1 mol L-1 (pH 1.0) and Ringer buffer (pH 11.0) as supporting electrolytes. The linear range for the amfepramone determination by differential pulse voltammetry (DPV) was 0.05 to 2.0 mg L-1 (r = 0.998) i...

  4. Numerical simulation of vapor flow and pressure drop across the demister of MSF desalination plant

    International Nuclear Information System (INIS)

    Janajreh, I.; Hasania, A.; Fath, H.

    2013-01-01

    Highlights: ► Porous media was used to simulate the pressure drop across desalination demister. ► Simulation results plausibly compared with experimental results. ► FC inlet Velocity distribution has no effect on the demister pressure drop. ► Demister inertial resistance affects pressure drop more than viscous resistance. - Abstract: This paper presents a numerical simulation of the water vapor flow in an MSF flash chamber along with the pressure drop across the demister. The demister is a simple porous blanket of metal wires mesh (usually made of stainless steel wires) which retains liquid droplets entrained by the vapor momentum to enhance the quality of the product water. Two main areas of concern in wire mesh mist eliminators are; (i) the pressure drop and (ii) the mist removal efficiency. The present simulation focuses only on the pressure drop across the demister. The simulation is carried out considering a full scale flashing chamber of a typical operational MSF desalination plant and of a real industrial demister dimensions. The study simulates the demister as porous media flow. It takes into account the vapor velocity, the dimension of the demister, its porosity and wire thickness. The obtained pressure drop was found to be within a reasonable agreement with the published literature data and it follows a trend compatible with Ergun’s equation as well as the empirical correlation of Svendsen.

  5. Formation and hematopoietic differentiation of human embryoid bodies by suspension and hanging drop cultures.

    Science.gov (United States)

    Cerdan, Chantal; Hong, Seok Ho; Bhatia, Mickie

    2007-10-01

    The in vitro aggregation of human embryonic stem cells (hESCs) into clusters termed embryoid bodies (EBs) allows for the spontaneous differentiation of cells representing endoderm, mesoderm, and ectoderm lineages. This stochastic process results however, in the generation of low numbers of differentiated cells, and can be enhanced to some extent by the addition of exogenous growth factors or overexpression of regulatory genes. In the authors' laboratory, the use of hematopoietic cytokines in combination with the mesoderm inducer bone morphogenetic protein-4 (BMP-4) was able to generate up to 90% of CD45(+) hematopoietic cells with colony-forming unit (CFU) activity. This unit describes two protocols that have been successfully applied in the authors' laboratory for the generation of EBs in (1) suspension and (2) hanging drop (HD) cultures from enzymatically digested clumps of undifferentiated hESC colonies.

  6. Hanging drop cultures of human testis and testis cancer samples: a model used to investigate activin treatment effects in a preserved niche.

    Science.gov (United States)

    Jørgensen, A; Young, J; Nielsen, J E; Joensen, U N; Toft, B G; Rajpert-De Meyts, E; Loveland, K L

    2014-05-13

    Testicular germ cell tumours of young adults, seminoma or non-seminomas, are preceded by a pre-invasive precursor, carcinoma in situ (CIS), understood to arise through differentiation arrest of embryonic germ cells. Knowledge about the malignant transformation of germ cells is currently limited by the lack of experimental models. The aim of this study was to establish an experimental tissue culture model to maintain normal and malignant germ cells within their niche and allow investigation of treatment effects. Human testis and testis cancer specimens from orchidectomies were cultured in 'hanging drops' and effects of activin A and follistatin treatment were investigated in seminoma cultures. Testis fragments with normal spermatogenesis or CIS cells were cultured for 14 days with sustained proliferation of germ cells and CIS cells and without increased apoptosis. Seminoma cultures survived 7 days, with proliferating cells detectable during the first 5 days. Activin A treatment significantly reduced KIT transcript and protein levels in seminoma cultures, thereby demonstrating a specific treatment response. Hanging drop cultures of human testis and testis cancer samples can be employed to delineate mechanisms governing growth of normal, CIS and tumorigenic germ cells retained within their niche.

  7. Suicidal Decapitation by Hanging-A Population-based Study.

    Science.gov (United States)

    Byard, Roger W; Gilbert, John D

    2018-05-01

    A prospective study was undertaken at Forensic Science SA over a 15-year period from July 2002 to June 2017 for all cases of adult (>18 years) suicidal hangings with decapitation. A total of 1446 cases of suicidal hangings were identified from a general population of approximately 1.5 million (1206 males-age range 18-97 years, average 42.6; and 240 females-age range 18-96 years, average 40.1). Only three cases of decapitation were found, all from long-drop hangings; these consisted of three males (ages 32-55 years; average 45 years). Spinal transections had occurred between the first and second, second and third, and third and fourth cervical vertebrae, respectively. In this study, the number of suicidal hangings with decapitation represented only 0.2% of the total number of hangings. These events are therefore extremely rare, most likely due to most suicidal hangings occurring from relatively low levels in a domestic environment. © 2017 American Academy of Forensic Sciences.

  8. Imprinted polymer-modified hanging mercury drop electrode for differential pulse cathodic stripping voltammetric analysis of creatine.

    Science.gov (United States)

    Lakshmi, Dhana; Sharma, Piyush S; Prasad, Bhim B

    2007-06-15

    The molecularly imprinted polymer [poly(p-aminobenzoicacid-co-1,2-dichloroethane)] film casting was made on the surface of a hanging mercury drop electrode by drop-coating method for the selective and sensitive evaluation of creatine in water, blood serum and pharmaceutical samples. The molecular recognition of creatine by the imprinted polymer was found to be specific via non-covalent (electrostatic) imprinting. The creatine binding could easily be detected by differential pulse, cathodic stripping voltammetric signal at optimised operational conditions: accumulation potential -0.01 V (versus Ag/AgCl), polymer deposition time 15s, template accumulation time 60s, pH 7.1 (supporting electrolyte< or =5 x 10(-4)M NaOH), scan rate 10 mV s(-1), pulse amplitude 25 mV. The modified sensor in the present study was found to be highly reproducible and selective with detection limit 0.11 ng mL(-1) of creatine. Cross-reactivity studies revealed no response to the addition of urea, creatinine and phenylalanine; however, some insignificant magnitude of current was observed for tryptophan and histidine in the test samples.

  9. Studying electron transfer through alkanethiol self-assembled monolayers on a hanging mercury drop electrode using potentiometric measurements.

    Science.gov (United States)

    Cohen-Atiya, Meirav; Mandler, Daniel

    2006-10-14

    A new approach based on measuring the change of the open-circuit potential (OCP) of a hanging mercury drop electrode (HMDE), modified with alkanethiols of different chain length conducted in a solution containing a mixture of Ru(NH3)6(2+) and Ru(NH3)6(3+) is used for studying electron transfer across the monolayer. Following the time dependence of the OCP allowed the extraction of the kinetic parameters, such as the charge transfer resistance (R(ct)) and the electron transfer rate constant (k(et)), for different alkanethiol monolayers. An electron tunneling coefficient, beta, of 0.9 A(-1) was calculated for the monolayers on Hg.

  10. Gas scavenging of insoluble vapors: Condensation of methyl salicylate vapor onto evaporating drops of water

    Science.gov (United States)

    Seaver, Mark; Peele, J. R.; Rubel, Glenn O.

    We have observed the evaporation of acoustically levitated water drops at 0 and 32% relative humidity in a moving gas stream which is nearly saturated with methyl salicylate vapor. The initial evaporation rate is characteristic of a pure water drop and gradually slows until the evaporation rate becomes that of pure methyl salicylate. The quantity of condensed methyl salicylate exceeds its Henry's law solubility in water by factors of more than 30-50. This apparent violation of Henry's law agrees with the concentration enhancements in the liquid phase found by glotfelty et al. (1987, Nature235, 602-605) during their field measurements of organophorus pesticides in fog water. Under our conditions, visual evidence demonstrates the presence of two liquid phases, thus invalidating the use of Henry's law. A continuum evaporation-condensation model for an immiscible two-component system which accounts for evaporative self-cooling of the drop correctly predicts the amount of methyl salicylate condensed onto the water drops.

  11. Creatinine sensor based on a molecularly imprinted polymer-modified hanging mercury drop electrode.

    Science.gov (United States)

    Lakshmi, Dhana; Prasad, Bhim Bali; Sharma, Piyush Sindhu

    2006-09-15

    Molecularly imprinted polymers (MIP) have been elucidated to work as artificial receptors. In our present study, a MIP was applied as a molecular recognition element to a chemical sensor. We have constructed a creatinine sensor based on a MIP layer selective for creatinine and its differential pulse, cathodic stripping voltammetric detection (DPCSV) on a hanging mercury drop electrode (HMDE). The creatinine sensor was fabricated by the drop coating of dimethylformamide (DMF) solution of a creatinine-imprinted polymer onto the surface of HMDE. The modified-HMDE, preanodised in neutral medium at +0.4V versus Ag/AgCl for 120s, exhibited a marked enhancement in DPCSV current in comparison to the less anodised (

  12. Hanging drop monoculture for selection of optimal antioxidants during in vitro maturation of porcine oocytes.

    Science.gov (United States)

    Ishikawa, S; Machida, R; Hiraga, K; Hiradate, Y; Suda, Y; Tanemura, K

    2014-04-01

    We analysed the effect of three antioxidants that have different functional mechanisms on the in vitro maturation (IVM) of porcine oocytes. Single oocyte monoculture using the hanging drop (HD) system has some advantages such as improving analysis efficiency brought by the smaller number of samples than the number of oocytes cultured in one drop. Direct effects of ligands on single oocytes could also be detected without considering the effects of paracrine factors from other oocytes. After 22 h of pre-culture, denuded oocytes were cultured for 22 h with 0.01 and 0.1 μg/ml of L-carnitine (LC), lactoferrin (LF) or sulforaphane (SF) in the presence/non-presence of oxidant stress induced by H2O2 supplementation to evaluate the reducing effects against oxidative stress on nuclear maturation. As a result, compared with LC and SF, LF showed effective reduction in oxidative stress at a lower concentration (0.01 μg/ml), suggesting that LF is a more effective antioxidant in porcine oocyte IVM. Additionally, LF also increased maturation rate even in culture without H2O2. Our results clearly suggest that the HD monoculture system is useful for screening the substances that affect porcine oocyte culture. © 2014 Blackwell Verlag GmbH.

  13. Hematopoietic Stem and Progenitor Cell Expansion in Contact with Mesenchymal Stromal Cells in a Hanging Drop Model Uncovers Disadvantages of 3D Culture.

    Science.gov (United States)

    Schmal, Olga; Seifert, Jan; Schäffer, Tilman E; Walter, Christina B; Aicher, Wilhelm K; Klein, Gerd

    2016-01-01

    Efficient ex vivo expansion of hematopoietic stem cells with a concomitant preservation of stemness and self-renewal potential is still an unresolved ambition. Increased numbers of methods approaching this issue using three-dimensional (3D) cultures were reported. Here, we describe a simplified 3D hanging drop model for the coculture of cord blood-derived CD34(+) hematopoietic stem and progenitor cells (HSPCs) with bone marrow-derived mesenchymal stromal cells (MSCs). When seeded as a mixed cell suspension, MSCs segregated into tight spheroids. Despite the high expression of niche-specific extracellular matrix components by spheroid-forming MSCs, HSPCs did not migrate into the spheroids in the initial phase of coculture, indicating strong homotypic interactions of MSCs. After one week, however, HSPC attachment increased considerably, leading to spheroid collapse as demonstrated by electron microscopy and immunofluorescence staining. In terms of HSPC proliferation, the conventional 2D coculture system was superior to the hanging drop model. Furthermore, expansion of primitive hematopoietic progenitors was more favored in 2D than in 3D, as analyzed in colony-forming assays. Conclusively, our data demonstrate that MSCs, when arranged with a spread (monolayer) shape, exhibit better HSPC supportive qualities than spheroid-forming MSCs. Therefore, 3D systems are not necessarily superior to traditional 2D culture in this regard.

  14. Effect of superficial velocity on vaporization pressure drop with propane in horizontal circular tube

    Science.gov (United States)

    Novianto, S.; Pamitran, A. S.; Nasruddin, Alhamid, M. I.

    2016-06-01

    Due to its friendly effect on the environment, natural refrigerants could be the best alternative refrigerant to replace conventional refrigerants. The present study was devoted to the effect of superficial velocity on vaporization pressure drop with propane in a horizontal circular tube with an inner diameter of 7.6 mm. The experiments were conditioned with 4 to 10 °C for saturation temperature, 9 to 20 kW/m2 for heat flux, and 250 to 380 kg/m2s for mass flux. It is shown here that increased heat flux may result in increasing vapor superficial velocity, and then increasing pressure drop. The present experimental results were evaluated with some existing correlations of pressure drop. The best prediction was evaluated by Lockhart-Martinelli (1949) with MARD 25.7%. In order to observe the experimental flow pattern, the present results were also mapped on the Wang flow pattern map.

  15. Reassembly of anterior pituitary organization by hanging drop three-dimensional cell culture.

    Science.gov (United States)

    Tsukada, Takehiro; Kouki, Tom; Fujiwara, Ken; Ramadhani, Dini; Horiguchi, Kotaro; Kikuchi, Motoshi; Yashiro, Takashi

    2013-08-29

    The anterior pituitary gland comprises 5 types of hormone-producing cells and non-endocrine cells, such as folliculostellate (FS) cells. The cells form a lobular structure surrounded by extracellular matrix (ECM) but are not randomly distributed in each lobule; hormone-producing cells have affinities for specific cell types (topographic affinity), and FS cells form a homotypic meshwork. To determine whether this cell and ECM organization can be reproduced in vitro, we developed a 3-dimensional (3D) model that utilizes hanging drop cell culture. We found that the topographic affinities of hormone-producing cells were indeed maintained (ie, GH to ACTH cells, GH to TSH cells, PRL to LH/FSH cells). Fine structures in hormone-producing cells retained their normal appearance. In addition, FS cells displayed well-developed cytoplasmic protrusions, which interconnected with adjacent FS cells to form a 3D meshwork. In addition, reassembly of gap junctions and pseudofollicles among FS cells was observed in cell aggregates. Major ECM components-collagens and laminin-were deposited and distributed around the cells. In sum, the dissociated anterior pituitary cells largely maintained their in vivo anterior pituitary architectures. This culture system appears to be a powerful experimental tool for detailed analysis of anterior pituitary cell organization.

  16. Three-dimensional spheroid culture targeting versatile tissue bioassays using a PDMS-based hanging drop array.

    Science.gov (United States)

    Kuo, Ching-Te; Wang, Jong-Yueh; Lin, Yu-Fen; Wo, Andrew M; Chen, Benjamin P C; Lee, Hsinyu

    2017-06-29

    Biomaterial-based tissue culture platforms have emerged as useful tools to mimic in vivo physiological microenvironments in experimental cell biology and clinical studies. We describe herein a three-dimensional (3D) tissue culture platform using a polydimethylsiloxane (PDMS)-based hanging drop array (PDMS-HDA) methodology. Multicellular spheroids can be achieved within 24 h and further boosted by incorporating collagen fibrils in PDMS-HDA. In addition, the spheroids generated from different human tumor cells exhibited distinct sensitivities toward drug chemotherapeutic agents and radiation as compared with two-dimensional (2D) cultures that often lack in vivo-like biological insights. We also demonstrated that multicellular spheroids may enable key hallmarks of tissue-based bioassays, including drug screening, tumor dissemination, cell co-culture, and tumor invasion. Taken together, these results offer new opportunities not only to achieve the active control of 3D multicellular spheroids on demand, but also to establish a rapid and cost-effective platform to study anti-cancer therapeutics and tumor microenvironments.

  17. Hematopoietic Stem and Progenitor Cell Expansion in Contact with Mesenchymal Stromal Cells in a Hanging Drop Model Uncovers Disadvantages of 3D Culture

    Directory of Open Access Journals (Sweden)

    Olga Schmal

    2016-01-01

    Full Text Available Efficient ex vivo expansion of hematopoietic stem cells with a concomitant preservation of stemness and self-renewal potential is still an unresolved ambition. Increased numbers of methods approaching this issue using three-dimensional (3D cultures were reported. Here, we describe a simplified 3D hanging drop model for the coculture of cord blood-derived CD34+ hematopoietic stem and progenitor cells (HSPCs with bone marrow-derived mesenchymal stromal cells (MSCs. When seeded as a mixed cell suspension, MSCs segregated into tight spheroids. Despite the high expression of niche-specific extracellular matrix components by spheroid-forming MSCs, HSPCs did not migrate into the spheroids in the initial phase of coculture, indicating strong homotypic interactions of MSCs. After one week, however, HSPC attachment increased considerably, leading to spheroid collapse as demonstrated by electron microscopy and immunofluorescence staining. In terms of HSPC proliferation, the conventional 2D coculture system was superior to the hanging drop model. Furthermore, expansion of primitive hematopoietic progenitors was more favored in 2D than in 3D, as analyzed in colony-forming assays. Conclusively, our data demonstrate that MSCs, when arranged with a spread (monolayer shape, exhibit better HSPC supportive qualities than spheroid-forming MSCs. Therefore, 3D systems are not necessarily superior to traditional 2D culture in this regard.

  18. Effects of hanging drop culture conditions on embryoid body formation and neuronal cell differentiation using mouse embryonic stem cells: optimization of culture conditions for the formation of well-controlled embryoid bodies.

    Science.gov (United States)

    Ohnuki, Yoshitsugu; Kurosawa, Hiroshi

    2013-05-01

    Hanging drop (HD) cultures were carried out with a drop volume of either 20 or 30 μl. An incubation period of 3 days was determined to be appropriate for the formation of well-controlled embryoid bodies (EBs), and the initial cell number was identified as the most critical factor in the growth and neuronal cell differentiation of EBs. Copyright © 2012 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  19. Formation of stable small cell number three-dimensional ovarian cancer spheroids using hanging drop arrays for preclinical drug sensitivity assays.

    Science.gov (United States)

    Raghavan, Shreya; Ward, Maria R; Rowley, Katelyn R; Wold, Rachel M; Takayama, Shuichi; Buckanovich, Ronald J; Mehta, Geeta

    2015-07-01

    Ovarian cancer grows and metastasizes from multicellular spheroidal aggregates within the ascites fluid. Multicellular tumor spheroids are therefore physiologically significant 3D in vitro models for ovarian cancer research. Conventional hanging drop cultures require high starting cell numbers, and are tedious for long-term maintenance. In this study, we generate stable, uniform multicellular spheroids using very small number of ovarian cancer cells in a novel 384 well hanging drop array platform. We used novel tumor spheroid platform and two ovarian cancer cell lines (A2780 and OVCAR3) to demonstrate the stable incorporation of as few as 10 cells into a single spheroid. Spheroids had uniform geometry, with projected areas (42.60×10(3)μm-475.22×10(3)μm(2) for A2780 spheroids and 37.24×10(3)μm(2)-281.01×10(3)μm(2) for OVCAR3 spheroids) that varied as a function of the initial cell seeding density. Phalloidin and nuclear stains indicated cells formed tightly packed spheroids with demarcated boundaries and cell-cell interaction within spheroids. Cells within spheroids demonstrated over 85% viability. 3D tumor spheroids demonstrated greater resistance (70-80% viability) to cisplatin chemotherapy compared to 2D cultures (30-50% viability). Ovarian cancer spheroids can be generated from limited cell numbers in high throughput 384 well plates with high viability. Spheroids demonstrate therapeutic resistance relative to cells in traditional 2D culture. Stable incorporation of low cell numbers is advantageous when translating this research to rare patient-derived cells. This system can be used to understand ovarian cancer spheroid biology, as well as carry out preclinical drug sensitivity assays. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Optimization of a single-drop microextraction method for multielemental determination by electrothermal vaporization inductively coupled plasma mass spectrometry following in situ vapor generation

    International Nuclear Information System (INIS)

    Gil, Sandra; Loos-Vollebregt, Margaretha T.C. de; Bendicho, Carlos

    2009-01-01

    A headspace single-drop microextraction (HS-SDME) method has been developed in combination with electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS) for the simultaneous determination of As, Sb, Bi, Pb, Sn and Hg in aqueous solutions. Vapor generation is carried out in a 40 mL volume closed-vial containing a solution with the target analytes in hydrochloric acid and potassium ferricyanide medium. Hydrides (As, Sb, Bi, Pb, Sn) and Hg vapor are trapped onto an aqueous single drop (3 μL volume) containing Pd(II), followed by the subsequent injection in the ETV. Experimental variables such as medium composition, sodium tetrahydroborate (III) volume and concentration, stirring rate, extraction time, sample volume, ascorbic acid concentration and palladium amount in the drop were fully optimized. The limits of detection (LOD) (3σ criterion) of the proposed method for As, Sb, Bi, Pb, Sn and Hg were 0.2, 0.04, 0.01, 0.07, 0.09 and 0.8 μg/L, respectively. Enrichment factors of 9, 85, 138, 130, 37 and 72 for As, Sb, Bi, Pb, Sn and Hg, respectively, were achieved in 210 s. The relative standard deviations (N = 5) ranged from 4 to 8%. The proposed HS-SDME-ETV-ICP-MS method has been applied for the determination of As, Sb, Bi, Pb, Sn and Hg in NWRI TM-28.3 certified reference material.

  1. A novel hanging spherical drop system for the generation of cellular spheroids and high throughput combinatorial drug screening.

    Science.gov (United States)

    Neto, A I; Correia, C R; Oliveira, M B; Rial-Hermida, M I; Alvarez-Lorenzo, C; Reis, R L; Mano, J F

    2015-04-01

    We propose a novel hanging spherical drop system for anchoring arrays of droplets of cell suspension based on the use of biomimetic superhydrophobic flat substrates, with controlled positional adhesion and minimum contact with a solid substrate. By facing down the platform, it was possible to generate independent spheroid bodies in a high throughput manner, in order to mimic in vivo tumour models on the lab-on-chip scale. To validate this system for drug screening purposes, the toxicity of the anti-cancer drug doxorubicin in cell spheroids was tested and compared to cells in 2D culture. The advantages presented by this platform, such as feasibility of the system and the ability to control the size uniformity of the spheroid, emphasize its potential to be used as a new low cost toolbox for high-throughput drug screening and in cell or tissue engineering.

  2. Preparation of anti-inflammatory mesenchymal stem/precursor cells (MSCs) through sphere formation using hanging-drop culture technique.

    Science.gov (United States)

    Bartosh, Thomas J; Ylostalo, Joni H

    2014-02-06

    Herein, we describe a protocol for preparation of pre-activated anti-inflammatory human mesenchymal stem/precursor cells (MSCs) in 3-D culture without addition of exogenous chemicals or gene-transfer approaches. MSCs are an easily procurable source of multipotent adult stem cells with therapeutic potential largely attributed to their paracrine regulation of inflammation and immunity. However, the culture conditions to prepare the ideal MSCs for cell therapy remain elusive. Furthermore, the reported lag time for activation in experimental models has prompted investigations on pre-activating the cells prior to their administration. In this protocol, standard 2-D culture-expanded MSCs are activated by aggregation into 3-D spheres using hanging-drop cultures. MSC activation is evaluated by real-time PCR and/or ELISA for anti-inflammatory factors (TSG-6, STC-1, PGE2), and by a functional assay using lipopolysaccharide-stimulated macrophage cultures. Further, we elucidate methods to prepare MSC-sphere conditioned medium, intact spheres, and suspension of single cells from spheres for experimental and clinical applications. Copyright © 2014 John Wiley & Sons, Inc.

  3. Preparation of anti-inflammatory mesenchymal stem/precursor cells (MSCs) through sphere formation using hanging drop culture technique

    Science.gov (United States)

    Bartosh, Thomas J.

    2014-01-01

    Herein, we describe a protocol for preparation of pre-activated anti-inflammatory human mesenchymal stem/precursor cells (MSCs) in 3D culture without addition of exogenous chemicals or gene transfer approaches. MSCs are an easily procurable source of multipotent adult stem cells with therapeutic potential largely attributed to their paracrine regulation of inflammation and immunity. However, the culture conditions to prepare the ideal MSCs for cell therapy remain elusive. Furthermore, reported lag time for activation in experimental models have prompted investigations to pre-activate the cells prior to their administration. In this protocol, standard 2D culture expanded MSCs are activated by aggregation into 3D spheres using hanging drop cultures. MSC activation is evaluated by real-time PCR and/or ELISA for anti-inflammatory factors (TSG-6, STC-1, PGE2), and by a functional assay using lipopolysaccharide-stimulated macrophage cultures. Furthermore, we elucidate methods to prepare MSC sphere conditioned medium, intact spheres, and suspension of single cells from spheres for experimental and clinical applications. PMID:24510769

  4. First steps towards the successful surface-based cultivation of human embryonic stem cells in hanging drop systems.

    Science.gov (United States)

    Schulz, Julia C; Stumpf, Patrick S; Katsen-Globa, Alisa; Sachinidis, Agapios; Hescheler, Jürgen; Zimmermann, Heiko

    2012-11-01

    Miniaturization and parallelization of cell culture procedures are in focus of research in order to develop test platforms with low material consumption and increased standardization for toxicity and drug screenings. The cultivation in hanging drops (HDs) is a convenient and versatile tool for biological applications and represents an interesting model system for the screening applications due to its uniform shape, the advantageous gas supply, and the small volume. However, its application has so far been limited to non-adherent and aggregate forming cells. Here, we describe for the first time the proof-of-principle regarding the adherent cultivation of human embryonic stem cells in HD. For this microcarriers were added to the droplet as dynamic cultivation surfaces resulting in a maintained pluripotency and proliferation capacity for 10 days. This enables the HD technique to be extended to the cultivation of adherence-dependent stem cells. Also, the possible automation of this method by implementation of liquid handling systems opens new possibilities for miniaturized screenings, the improvement of cultivation and differentiation conditions, and toxicity and drug development.

  5. Capillary Thinning of Particle-laden Drops

    Science.gov (United States)

    Wagoner, Brayden; Thete, Sumeet; Jahns, Matt; Doshi, Pankaj; Basaran, Osman

    2015-11-01

    Drop formation is central in many applications such as ink-jet printing, microfluidic devices, and atomization. During drop formation, a thinning filament is created between the about-to-form drop and the fluid hanging from the nozzle. Therefore, the physics of capillary thinning of filaments is key to understanding drop formation and has been thoroughly studied for pure Newtonian fluids. The thinning dynamics is, however, altered completely when the fluid contains particles, the physics of which is not well understood. In this work, we explore the impact of solid particles on filament thinning and drop formation by using a combination of experiments and numerical simulations.

  6. Pendent_Drop: An ImageJ Plugin to Measure the Surface Tension from an Image of a Pendent Drop

    Directory of Open Access Journals (Sweden)

    Adrian Daerr

    2016-01-01

    Full Text Available The pendent drop method for surface tension measurement consists in analysing the shape of an axisymmetric drop hanging from a capillary tube. This software is an add-on for the public domain image processing software ImageJ which matches a theoretical profile to the contour of a pendent drop, either interactively or by automatically minimising the mismatch. It provides an estimate of the surface tension, drop volume and surface area from the best matching parameters. It can be used in a headless setup. It is hosted on http://fiji.sc/List_of_update_sites with the source code on https://github.com/adaerr/pendent-drop

  7. Electrochemical behavior of phytochelatins and related peptides at the hanging mercury drop electrode in the presence of cobalt(II) ions.

    Science.gov (United States)

    Dorcák, Vlastimil; Sestáková, Ivana

    2006-01-01

    Direct current voltammetry and differential pulse voltammetry have been used to investigate the electrochemical behaviour of two phytochelatins: heptapeptide (gamma-Glu-Cys)3-Gly and pentapeptide (gamma-Glu-Cys)2-Gly, tripeptide glutathione gamma-Glu-Cys-Gly and its fragments: dipeptides Cys-Gly and gamma-Glu-Cys at the hanging mercury drop electrode in the presence of cobalt(II) ions. Most interesting results were obtained with direct current voltammetry in the potential region of -0.80 V up to -1.80 V. Differential pulse voltammetry of the same solutions of Co(II) with peptides gives more complicated voltammograms with overlapping peaks, probably in connection with the influence of adsorption at slow scan rates necessarily used in this method. However, in using Brdicka catalytic currents for analytical purposes, differential pulse voltammograms seem to be more helpful. Presented investigations have shown that particularly the prewave of cobalt(II) allows distinguishing among phytochelatins, glutathione, and its fragments.

  8. Direct voltammetric specific recognition of dopamine using AlIII-DA complexes at the hanging mercury drop electrode.

    Science.gov (United States)

    Zhang, Fuping; Zhang, Min; Cheng, Jiongjia; Yang, Li; Ji, Ming; Bi, Shuping

    2007-11-01

    In this paper, we firstly report the direct voltammetric recognition and determination of dopamine (DA) by using Al(III)-DA complexes at the hanging mercury drop electrode (HMDE). A new sensitive cathodic peak of Al(III)-DA can be detected at -900 mV (vs. SCE) in 0.1 M NH(4)Cl-NH(3).H(2)O-0.1 M KCl buffer solution at pH 8.5. This unique -900 mV cathodic peak arises from the specific interaction between Al(III) and DA on the HMDE, whereas other substances with similar structures, such as L-dopa, epinephrine (EP), norepinephrine (NE), catechols, caffeic acid (CA), trihydric phenols and tiron, do not yield any new peak on the voltammograms in the potential range from -100 to -1200 mV when Al(III) is added. The distinct voltammetric characteristic of the recognition of DA can effectively inhibit the interferences of both ascorbic acid and uric acid in the DA determination by the direct electrochemistry, which is a major difficulty when a solid electrode is used. The proposed method can be anticipated as an effective means for the recognition of DA in the elucidation of the mechanisms of Parkinson's disease (PD) and Alzheimer's disease (AD) in the presence of Al(III).

  9. Life-History Traits of the Model Organism Pristionchus pacificus Recorded Using the Hanging Drop Method: Comparison with Caenorhabditis elegans.

    Science.gov (United States)

    Gilarte, Patricia; Kreuzinger-Janik, Bianca; Majdi, Nabil; Traunspurger, Walter

    2015-01-01

    The nematode Pristionchus pacificus is of growing interest as a model organism in evolutionary biology. However, despite multiple studies of its genetics, developmental cues, and ecology, the basic life-history traits (LHTs) of P. pacificus remain unknown. In this study, we used the hanging drop method to follow P. pacificus at the individual level and thereby quantify its LHTs. This approach allowed direct comparisons with the LHTs of Caenorhabditis elegans recently determined using this method. When provided with 5×10(9) Escherichia coli cells ml(-1) at 20°C, the intrinsic rate of natural increase of P. pacificus was 1.125 (individually, per day); mean net production was 115 juveniles produced during the life-time of each individual, and each nematode laid an average of 270 eggs (both fertile and unfertile). The mean age of P. pacificus individuals at first reproduction was 65 h, and the average life span was 22 days. The life cycle of P. pacificus is therefore slightly longer than that of C. elegans, with a longer average life span and hatching time and the production of fewer progeny.

  10. Life-History Traits of the Model Organism Pristionchus pacificus Recorded Using the Hanging Drop Method: Comparison with Caenorhabditis elegans.

    Directory of Open Access Journals (Sweden)

    Patricia Gilarte

    Full Text Available The nematode Pristionchus pacificus is of growing interest as a model organism in evolutionary biology. However, despite multiple studies of its genetics, developmental cues, and ecology, the basic life-history traits (LHTs of P. pacificus remain unknown. In this study, we used the hanging drop method to follow P. pacificus at the individual level and thereby quantify its LHTs. This approach allowed direct comparisons with the LHTs of Caenorhabditis elegans recently determined using this method. When provided with 5×10(9 Escherichia coli cells ml(-1 at 20°C, the intrinsic rate of natural increase of P. pacificus was 1.125 (individually, per day; mean net production was 115 juveniles produced during the life-time of each individual, and each nematode laid an average of 270 eggs (both fertile and unfertile. The mean age of P. pacificus individuals at first reproduction was 65 h, and the average life span was 22 days. The life cycle of P. pacificus is therefore slightly longer than that of C. elegans, with a longer average life span and hatching time and the production of fewer progeny.

  11. Expression, purification, crystallization and preliminary X-ray studies of the Ebola VP35 interferon inhibitory domain

    International Nuclear Information System (INIS)

    Leung, Daisy W.; Ginder, Nathaniel D.; Nix, Jay C.; Basler, Christopher F.; Honzatko, Richard B.; Amarasinghe, Gaya K.

    2009-01-01

    Native and selenomethionine-labeled crystals of Ebola VP35 interferon inhibitory domain were obtained by the hanging-drop vapor-diffusion method. Ebola VP35 is a multifunctional protein that is important for host immune suppression and pathogenesis. VP35 contains an N-terminal oligomerization domain and a C-terminal interferon inhibitory domain (IID). Mutations within the VP35 IID result in loss of host immune suppression. Here, efforts to crystallize recombinantly overexpressed VP35 IID that was purified from Escherichia coli are described. Native and selenomethionine-labeled crystals belonging to the orthorhombic space group P2 1 2 1 2 1 were obtained by the hanging-drop vapor-diffusion method and diffraction data were collected at the ALS synchrotron

  12. A simple hanging drop cell culture protocol for generation of 3D spheroids.

    Science.gov (United States)

    Foty, Ramsey

    2011-05-06

    Studies of cell-cell cohesion and cell-substratum adhesion have historically been performed on monolayer cultures adherent to rigid substrates. Cells within a tissue, however, are typically encased within a closely packed tissue mass in which cells establish intimate connections with many near-neighbors and with extracellular matrix components. Accordingly, the chemical milieu and physical forces experienced by cells within a 3D tissue are fundamentally different than those experienced by cells grown in monolayer culture. This has been shown to markedly impact cellular morphology and signaling. Several methods have been devised to generate 3D cell cultures including encapsulation of cells in collagen gels or in biomaterial scaffolds. Such methods, while useful, do not recapitulate the intimate direct cell-cell adhesion architecture found in normal tissues. Rather, they more closely approximate culture systems in which single cells are loosely dispersed within a 3D meshwork of ECM products. Here, we describe a simple method in which cells are placed in hanging drop culture and incubated under physiological conditions until they form true 3D spheroids in which cells are in direct contact with each other and with extracellular matrix components. The method requires no specialized equipment and can be adapted to include addition of any biological agent in very small quantities that may be of interest in elucidating effects on cell-cell or cell-ECM interaction. The method can also be used to co-culture two (or more) different cell populations so as to elucidate the role of cell-cell or cell-ECM interactions in specifying spatial relationships between cells. Cell-cell cohesion and cell-ECM adhesion are the cornerstones of studies of embryonic development, tumor-stromal cell interaction in malignant invasion, wound healing, and for applications to tissue engineering. This simple method will provide a means of generating tissue-like cellular aggregates for measurement of

  13. Comparative study of P19 EC stem cell differentiation in between conventional hanging drop and the zebrafish chorion as a bio-derived material.

    Science.gov (United States)

    Dae Seok Na; Lee, Hwang; Sun Uk Kim; Chang Nam Hwang; Sang Ho Lee; Ji Yoon Kang; Jai Kyeong Kim; James Jungho Pak

    2008-07-01

    Various materials including glass and polymers have been widely used for stem cell culture due to their biocompatibility. However, the roles of these materials are fundamentally limited because they cannot realize or imitate the complex biological functions of living tissues, except in very simple cases. Here, the development of a bio-derived material suitable for stem cell culture and improvement of differentiation efficiency to specific cell lineages with no stimulating agents by using a chorion obtained from a fertilized zebrafish egg through the removal of the yolk and embryonic cell mass from the egg is reported. Mouse P19 EC stem cells introduced into the empty chorion form a uniform embryoid body (EB) without addition of any inducing agent. It is demonstrated that the zebrafish chorion with nanopores improves efficiencies greatly in the EB formation, cell proliferation, and lineage-specific differentiations compared to those of the conventional hanging drop culture method.

  14. Identification of Hedgehog signaling outcomes in mouse testis development using a hanging drop-culture system.

    Science.gov (United States)

    Szczepny, Anette; Hogarth, Cathryn A; Young, Julia; Loveland, Kate L

    2009-02-01

    The Hedgehog (Hh) signaling pathway affects fetal testis growth. Recently, we described the dynamic cellular production of Hh signaling pathway components in juvenile and adult rodent testes. The Hh signaling is understood to regulate cord formation in the fetal testis, but minimal knowledge exists regarding how Hh signaling impacts the postnatal testis. To investigate this, we employed hanging drop cultures, which are used routinely in embryoid body formation. This approach has the advantage of using small media volume, and we examined its suitability for short-term culture of both murine embryonic gonads and adult testis tubules. The effects of cyclopamine, a specific Hh signaling inhibitor, were examined following culture of Embryonic Day 11.5 urogenital ridges (as control) and adult seminiferous tubule fragments for 24-48 h using histological, cell proliferation, and gene expression analyses. Cultured embryonic testes displayed generally normal cord structure, anti-Müllerian hormone (Amh) expression, and cell proliferation; known Hh target gene expression (Gli1, osteopontin, official symbol Spp1, and Amh) was altered in response to cyclopamine. Cultured adult tubules exhibited some loss of seminiferous epithelium organization over 48 h. Spermatogonia continued to proliferate, however, and no significant loss of viability was noted overall. Addition of cyclopamine significantly affected levels of Gli1, Igfbp6, Ccnd2 (cyclin D2), Ccnb1 (cyclin B1), Spp1, Kit, and Amh mRNAs; these genes have been shown previously to be expressed in Sertoli and germ cells. These novel results identify Hh target genes in the testis and demonstrate this signaling pathway likely affects cell survival and differentiation in the context of normal adult testis.

  15. Comparison of the lateral retention forces on sessile and pendant water drops on a solid surface

    Science.gov (United States)

    de la Madrid, Rafael; Whitehead, Taylor; Irwin, George M.

    2015-06-01

    We present a simple experiment that demonstrates how a water drop hanging from a Plexiglas surface (pendant drop) experiences a lateral retention force that is comparable to, and in some cases larger than, the lateral retention force on a drop resting on top of the surface (sessile drop). The experiment also affords a simple demonstration of the Coriolis effect in two dimensions.

  16. Linear scan voltammetric indirect determination of Al(III) by the catalytic cathodic response of norepinephrine at the hanging mercury drop electrode.

    Science.gov (United States)

    Zhang, Fuping; Ji, Ming; Xu, Quan; Yang, Li; Bi, Shuping

    2005-09-01

    The biological effects of aluminum (Al) have received much attention in recent years. Al is of basic relevance as concern with its reactivity and bioavailability. In this paper, the electrochemical behaviors of norepinephrine (NE) in the absence and presence of Al(III) at the hanging mercury drop electrode have been studied and applied to the practical analysis. Highly selective catalytic cathodic peak of NE is yielded by linear scan voltammetry (LSV) at -1.32 V (vs. SCE). A linear relationship holds between the cathodic peak current and the Al(III) concentration. It has been successfully applied to the determination of Al(III) in real waters and synthetic biological samples with satisfying results, which are in accordance with those obtained by ICP-AES method. The electrochemical properties and the mechanisms of the peaks in the presence and absence of Al(III) have been explored. The results show that they are irreversible adsorptive hydrogen catalytic waves. These studies not only enrich the methods of determining Al, but also lay foundations of further understanding of the mechanisms of neurodementia.

  17. Developing a continuous flow-square wave voltammetry method for determination of atrazine in soil solutions using the hanging mercury drop electrode

    Directory of Open Access Journals (Sweden)

    Santos Luciana B. O. dos

    2006-01-01

    Full Text Available This work describes the development of a Continuous Flow-Square Wave Voltammetry method for determination of atrazine using the hanging mercury drop electrode. The best signal to noise ratio was obtained at the square wave frequency of 350 Hz and flow rate of 0.47 mL min-1. Under these conditions, the analytical curve obtained in 0.010 mol L-1 CaCl2 soil extracts in presence of 40 mmol L-1 BR buffer and 0.25 mol L-1 NaNO3 was linear for atrazine concentrations between 0.10 and 2.0 µg mL-1, with detection and quantification limits of 0.030 and 0.10 µg mL-1, respectively. The proposed method increased the analytical throughput in comparison with the batch methodology, allowing a sampling frequency of 72 h-1 to be accomplished. Besides, the sample consumption is significantly reduced, and only 341 µL are necessary for each analysis. The results obtained were similar to the ones obtained by HPLC, but the proposed method is faster and does not use organic solvents.

  18. Vapor generation rate model for dispersed drop flow

    International Nuclear Information System (INIS)

    Unal, C.; Tuzla, K.; Cokmez-Tuzla, A.F.; Chen, J.C.

    1991-01-01

    A comparison of predictions of existing nonequilibrium post-CHF heat transfer models with the recently obtained rod bundle data has been performed. The models used the experimental conditions and wall temperatures to predict the heat flux and vapor temperatures at the location of interest. No existing model was able to reasonably predict the vapor superheat and the wall heat flux simultaneously. Most of the models, except Chen-Sundaram-Ozkaynak, failed to predict the wall heat flux, while all of the models could not predict the vapor superheat data or trends. A recently developed two-region heat transfer model, the Webb-Chen two-region model, did not give a reasonable prediction of the vapor generation rate in the far field of the CHF point. A new correlation was formulated to predict the vapor generation rate in convective dispersed droplet flow in terms of thermal-hydraulic parameters and thermodynamic properties. A comparison of predictions of the two-region heat transfer model, with the use of a presently developed correlation, with all the existing post-CHF data, including single-tube and rod bundle, showed significant improvements in predicting the vapor superheat and tube wall heat flux trends. (orig.)

  19. Low-level determination of silicon in steels by anodic stripping voltammetry on a hanging mercury drop electrode.

    Science.gov (United States)

    Rahier, A H; Lunardi, S; Nicolle, F; George, S M

    2010-10-15

    The sensitive differential pulse anodic stripping voltammetry (DPASV) proposed originally by Ishiyama et al. (2001) has been revised and improved to allow the accurate measurement of silicon on a hanging mercury drop electrode (HMDE) instead of a glassy carbon electrode. We assessed the rate of formation of the partially reduced β-silicododecamolybdate and found that metallic mercury promotes the reaction in the presence of a large concentration of Fe(3+). The scope of the method has been broadened by carrying out the measurements in the presence of a constant amount of Fe(3+). The limit of detection (LOD) of the method described in the present paper is 100 μg Sig(-1) of steel, with a relative precision ranging from 5% to 12%. It can be further enhanced to 700 ng Sig(-1) of steel provided the weight of the sample, the dilution factors, the duration of the electrolysis and the ballast of iron are adequately revised. The tolerance to several interfering species has been examined, especially regarding Al(3+), Cr(3+) and Cr VI species. The method was validated using four low-alloy ferritic steels certified by the National Institute of Standards and Technology (NIST). Its application to nickel base alloys as well as to less complicated matrixes is straightforward. It has also been successfully applied to the determination of free silicon into silicon carbide nano-powder. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Identification of Hedgehog Signaling Outcomes in Mouse Testis Development Using a Hanging Drop-Culture System1

    Science.gov (United States)

    Szczepny, Anette; Hogarth, Cathryn A.; Young, Julia; Loveland, Kate L.

    2008-01-01

    The Hedgehog (Hh) signaling pathway affects fetal testis growth. Recently, we described the dynamic cellular production of Hh signaling pathway components in juvenile and adult rodent testes. The Hh signaling is understood to regulate cord formation in the fetal testis, but minimal knowledge exists regarding how Hh signaling impacts the postnatal testis. To investigate this, we employed hanging drop cultures, which are used routinely in embryoid body formation. This approach has the advantage of using small media volume, and we examined its suitability for short-term culture of both murine embryonic gonads and adult testis tubules. The effects of cyclopamine, a specific Hh signaling inhibitor, were examined following culture of Embryonic Day 11.5 urogenital ridges (as control) and adult seminiferous tubule fragments for 24–48 h using histological, cell proliferation, and gene expression analyses. Cultured embryonic testes displayed generally normal cord structure, anti-Müllerian hormone (Amh) expression, and cell proliferation; known Hh target gene expression (Gli1, osteopontin, official symbol Spp1, and Amh) was altered in response to cyclopamine. Cultured adult tubules exhibited some loss of seminiferous epithelium organization over 48 h. Spermatogonia continued to proliferate, however, and no significant loss of viability was noted overall. Addition of cyclopamine significantly affected levels of Gli1, Igfbp6, Ccnd2 (cyclin D2), Ccnb1 (cyclin B1), Spp1, Kit, and Amh mRNAs; these genes have been shown previously to be expressed in Sertoli and germ cells. These novel results identify Hh target genes in the testis and demonstrate this signaling pathway likely affects cell survival and differentiation in the context of normal adult testis. PMID:18843087

  1. Study of the voltammetric behaviour of the ethalfluralin and methalpropalin and its determination in environmental matrices at hanging mercury drop electrode.

    Science.gov (United States)

    Thriveni, T; Kumar, J Rajesh; Lee, Jin Young; Sreedhar, N Y

    2009-04-01

    An electroanalytical method has been developed for the determination of the herbicides ethalfluralin[N-ethyl-N-(2-methyl-2-propenyl)-2,6-dinitro-4-(trifluoromethyl) bezenamine] and methalpropalin [N-(2-methyl-2-propenyl)-2, 6-dinitro-N-propyl-4 (trifluoromethyl) benzenamine] by differential pulse adsorptive stripping voltammetry (DP-AdSV) on a hanging mercury drop electrode (HMDE) with universal buffer as supporting electrolyte. The optimum adsorption conditions were found to be pH 6.0, an accumulation potential of -0.6 V (HMDE vs SCE), an accumulation time of 80 s. and scan rate 45 mVs(-1). Calibration curve is linear in the range 1.30 x 10(-9) to 1.32 x 10(-5) M of ethalfluralin and 1.13 x 10(-5) to 2.0 x 10(-8) M of methalpropalin with detection limits of 1.08 x 10(-9) and 1.87 x 10(-8) M, respectively. The relative SD and correlation coefficients were found to be 1.24%, 0.998 and 1.34%, 0.995, respectively for ten replicates. The method is applied to the determination of the ethalfluralin and methalpropalin in formulations and environmental matrices.

  2. Mixture effects of benzene, toluene, ethylbenzene, and xylenes (BTEX) on lung carcinoma cells via a hanging drop air exposure system.

    Science.gov (United States)

    Liu, Faye F; Escher, Beate I; Were, Stephen; Duffy, Lesley; Ng, Jack C

    2014-06-16

    A recently developed hanging drop air exposure system for toxicity studies of volatile chemicals was applied to evaluate the cell viability of lung carcinoma A549 cells after 1 and 24 h of exposure to benzene, toluene, ethylbenzene, and xylenes (BTEX) as individual compounds and as mixtures of four or six components. The cellular chemical concentrations causing 50% reduction of cell viability (EC50) were calculated using a mass balance model and came to 17, 12, 11, 9, 4, and 4 mmol/kg cell dry weight for benzene, toluene, ethylbenzene, m-xylene, o-xylene, and p-xylene, respectively, after 1 h of exposure. The EC50 decreased by a factor of 4 after 24 h of exposure. All mixture effects were best described by the mixture toxicity model of concentration addition, which is valid for chemicals with the same mode of action. Good agreement with the model predictions was found for benzene, toluene, ethylbenzene, and m-xylene at four different representative fixed concentration ratios after 1 h of exposure, but lower agreement with mixture prediction was obtained after 24 h of exposure. A recreated car exhaust mixture, which involved the contribution of the more toxic p-xylene and o-xylene, yielded an acceptable, but lower quality, prediction as well.

  3. Evaporation of a sessile water drop and a drop of aqueous salt solution.

    Science.gov (United States)

    Misyura, S Y

    2017-11-07

    The influence of various factors on the evaporation of drops of water and aqueous salt solution has been experimentally studied. Typically, in the studies of drop evaporation, only the diffusive vapor transfer, radiation and the molecular heat conduction are taken into account. However, vapor-gas convection plays an important role at droplet evaporation. In the absence of droplet boiling, the influence of gas convection turns out to be the prevailing factor. At nucleate boiling, a prevailing role is played by bubbles generation and vapor jet discharge at a bubble collapse. The gas convection behavior for water and aqueous salt solution is substantially different. With a growth of salt concentration over time, the influence of the convective component first increases, reaches an extremum and then significantly decreases. At nucleate boiling in a salt solution it is incorrect to simulate the droplet evaporation and the heat transfer in quasi-stationary approximation. The evaporation at nucleate boiling in a liquid drop is divided into several characteristic time intervals. Each of these intervals is characterized by a noticeable change in both the evaporation rate and the convection role.

  4. The origin of star-shaped oscillations of Leidenfrost drops

    Science.gov (United States)

    Ma, Xiaolei; Burton, Justin C.

    We experimentally investigate the oscillations of Leidenfrost drops of water, liquid nitrogen, ethanol, methanol, acetone and isopropyl alcohol. The drops levitate on a cushion of evaporated vapor over a hot, curved surface which keeps the drops stationary. We observe star-shaped modes along the periphery of the drop, with mode numbers n = 2 to 13. The number of observed modes is sensitive to the properties of the liquid. The pressure oscillation frequency in the vapor layer under the drop is approximately twice that of the drop frequency, which is consistent with a parametric forcing mechanism. However, the Rayleigh and thermal Marangoni numbers are of order 10,000, indicating that convection should play a dominating role as well. Surprisingly, we find that the wavelength and frequency of the oscillations only depend on the thickness of the liquid, which is twice the capillary length, and do not depend on the mode number, substrate temperature, or the substrate curvature. This robust behavior suggests that the wavelength for the oscillations is set by thermal convection inside the drop, and is less dependent on the flow in the vapor layer under the drop

  5. Hanging off a bar

    NARCIS (Netherlands)

    Mueller, F.; Walmink, W.; Toprak, C.; Bongers, Bert; Graether, E.; Hoven, van den E.A.W.H.

    2012-01-01

    Exertion Games involve physical effort and as a result can facilitate physical health benefits. We present Hanging off a Bar, an action hero-inspired Exertion Game in which players hang off an exercise bar over a virtual river for as long as possible. Initial observations from three events with

  6. Surface Tension Guided Hanging-Drop: Producing Controllable 3D Spheroid of High-Passaged Human Dermal Papilla Cells and Forming Inductive Microtissues for Hair-Follicle Regeneration.

    Science.gov (United States)

    Lin, Bojie; Miao, Yong; Wang, Jin; Fan, Zhexiang; Du, Lijuan; Su, Yongsheng; Liu, Bingcheng; Hu, Zhiqi; Xing, Malcolm

    2016-03-09

    Human dermal papilla (DP) cells have been studied extensively when grown in the conventional monolayer. However, because of great deviation from the real in vivo three-dimensional (3D) environment, these two-dimensional (2D) grown cells tend to lose the hair-inducible capability during passaging. Hence, these 2D caused concerns have motivated the development of novel 3D culture techniques to produce cellular microtissues with suitable mimics. The hanging-drop approach is based on surface tension-based technique and the interaction between surface tension and gravity field that makes a convergence of liquid drops. This study used this technique in a converged drop to form cellular spheroids of dermal papilla cells. It leads to a controllable 3Dspheroid model for scalable fabrication of inductive DP microtissues. The optimal conditions for culturing high-passaged (P8) DP spheroids were determined first. Then, the morphological, histological and functional studies were performed. In addition, expressions of hair-inductive markers including alkaline phosphatase, α-smooth muscle actin and neural cell adhesion molecule were also analyzed by quantitative RT-PCR, immunostaining and immunoblotting. Finally, P8-DP microtissues were coimplanted with newborn mouse epidermal cells (EPCs) into nude mice. Our results indicated that the formation of 3D microtissues not only endowed P8-DP microtissues many similarities to primary DP, but also confer these microtissues an enhanced ability to induce hair-follicle (HF) neogenesis in vivo. This model provides a potential to elucidate the native biology of human DP, and also shows the promising for the controllable and scalable production of inductive DP cells applied in future follicle regeneration.

  7. Modified adjustable suture hang-back recession: Description of technique and comparison with conventional adjustable hang-back recession

    Directory of Open Access Journals (Sweden)

    Siddharth Agrawal

    2017-01-01

    Full Text Available Purpose: This study aims to describe and compare modified hang-back recession with the conventional hang-back recession in large angle comitant exotropia (XT. Methods: A prospective, interventional, double-blinded, randomized study on adult patients (>18 years undergoing single eye recession-resection for large angle (>30 prism diopters constant comitant XT was conducted between January 2011 and December 2015. Patients in Group A underwent modified hang-back lateral rectus recession with adjustable knot while in Group B underwent conventional hang-back recession with an adjustable knot. Outcome parameters studied were readjustment rate, change in deviation at 6 weeks, complications and need for resurgery at 6 months. Results: The groups were comparable in terms of age and preoperative deviation. The patients with the modified hang back (Group A fared significantly better (P < 0.05 than those with conventional hang back (Group B in terms of lesser need for adjustment, greater correction in deviation at 6 weeks and lesser need for resurgery at 6 months. Conclusion: This modification offers several advantages, significantly reduces resurgery requirement and has no added complications.

  8. Numerical simulation of the effects of hanging sound absorbers on TABS cooling performance

    DEFF Research Database (Denmark)

    Rage, Nils; Kazanci, Ongun Berk; Olesen, Bjarne W.

    2016-01-01

    simulating a two-person office of 20 m2, with a typical cooling load of 42 W/m2. The results show that covering 60% of the ceiling surface with sound absorbers hanging at 300 mm from the ceiling active deck is expected to reduce the cooling capacity coefficient of TABS by 15.8%. This drops to 25......Recently there has been a considerable increase in the use of Thermally-Active Building Systems (TABS) in Europe as an energy-efficient and economical cooling and heating solution for buildings. However, this widespread solution requires large uncovered hard surfaces indoors, which can lead...... to a degradation of the room acoustic comfort. Therefore, challenges arise when this system has to be combined with acoustic requirements. Soffit-hanging sound absorbers embody a promising solution. This study focuses on quantifying their impact on the cooling performance of TABS, assessed by means of the cooling...

  9. Differential pulse cathodic stripping voltammetric determination of uranium with arsenazo-III at the hanging mercury dropping electrode

    Energy Technology Data Exchange (ETDEWEB)

    Kadi, M.W.; El-Shahawi, M.S. [Chemistry Dept., King Abdulaziz Univ., Jeddah (Saudi Arabia)

    2009-07-01

    An accurate, inexpensive and less laborious controlled adsorptive accumulation of uranium(VI)-arsenazo-III on a hanging mercury drop electrode (HMDE) has been developed for uranium(VI) determination. The method is based upon the collection of uranium(VI)-arsenazo-III complex at pH 5-6 at the HMDE and subsequent direct stripping measurement of the element in the nanomolar concentration level. The cathodic peak current (i{sub p,c}) of the adsorbed complex ions of uranium(VI) was measured at -0.35 V vs. Ag/AgCl reference electrode by differential pulse cathodic stripping voltammetry (DP-CSV), proceeded by an accumulation period of 150s2.5 in Britton-Robinson buffer of pH 5. The plot of the resulting i{sub p,c} vs. uranium(VI) concentration was linear in the range 2.1 x 10{sup -9} to 9.60 x 10{sup -7} mol L{sup -1} uranium(VI) and tended to level off at above 9.6 x 10{sup -7} mol L{sup -1}. The limits of detection and quantification of uranium(VI) were found to be 4.7 x 10{sup -10} and 1.5 x 10{sup -9} mol L{sup -1}, respectively. A relative standard deviation of {+-}2.39% (n = 5) at 8.5 x 10{sup -7} mol L{sup -1} uranium(VI) was obtained. The method was validated by comparing the results with that obtained by ICP-MS method with RSD less than {+-}3.3%. The method was applied successfully for the analysis of uranium in certified reference material (IAEA soil-7), and in phosphate fertilizers. (orig.)

  10. Experimental study of vapor explosion of molten salt and low boiling point liquid

    International Nuclear Information System (INIS)

    Iida, Yoshihiro; Takashima, Takeo

    1987-01-01

    Fundamental study of vapor explosion using small drops of high temperature liquid and low boiling point liquid and a series of small-scale vapor explosion tests are carried out. A single or plural drops of molten LiNO 3 are dropped into ethyl alcohol and the temperature range of two liquids wherein the fragmentation occurs is examined. The propagation phenomenon of vapor explosion between two drops is photographed and the pressure trace is proved to be well consistent with the behavior of the vapor bubble regions. A small amount of molten Flinak and tin which are enclosed in a test tube is dropped into tapped water. The temperature effect of two liquids onto the occurrence of vapor explosion is investigated. Some considerations are made with respect to the upper and lower temperature limits of vapor explosion to occur. A qualitative modeling of vapor explosion mechanism is proposed and discussed. (author)

  11. Common Cause Case Study: An Estimated Probability of Four Solid Rocket Booster Hold-Down Post Stud Hang-ups

    Science.gov (United States)

    Cross, Robert

    2005-01-01

    Until Solid Rocket Motor ignition, the Space Shuttle is mated to the Mobil Launch Platform in part via eight (8) Solid Rocket Booster (SRB) hold-down bolts. The bolts are fractured using redundant pyrotechnics, and are designed to drop through a hold-down post on the Mobile Launch Platform before the Space Shuttle begins movement. The Space Shuttle program has experienced numerous failures where a bolt has hung up. That is, it did not clear the hold-down post before liftoff and was caught by the SRBs. This places an additional structural load on the vehicle that was not included in the original certification requirements. The Space Shuttle is currently being certified to withstand the loads induced by up to three (3) of eight (8) SRB hold-down experiencing a "hang-up". The results of loads analyses performed for (4) stud hang-ups indicate that the internal vehicle loads exceed current structural certification limits at several locations. To determine the risk to the vehicle from four (4) stud hang-ups, the likelihood of the scenario occurring must first be evaluated. Prior to the analysis discussed in this paper, the likelihood of occurrence had been estimated assuming that the stud hang-ups were completely independent events. That is, it was assumed that no common causes or factors existed between the individual stud hang-up events. A review of the data associated with the hang-up events, showed that a common factor (timing skew) was present. This paper summarizes a revised likelihood evaluation performed for the four (4) stud hang-ups case considering that there are common factors associated with the stud hang-ups. The results show that explicitly (i.e. not using standard common cause methodologies such as beta factor or Multiple Greek Letter modeling) taking into account the common factor of timing skew results in an increase in the estimated likelihood of four (4) stud hang-ups of an order of magnitude over the independent failure case.

  12. Electrochemical study of the interaction between dsDNA and copper(I) using carbon paste and hanging mercury drop electrode.

    Science.gov (United States)

    Stanić, Z; Girousi, S

    2008-06-30

    The interaction of copper(I) with double-stranded (ds) calf thymus DNA was studied in solution and at the electrode surface by means of transfer voltammetry using a carbon paste electrode (CPE) as working electrode in 0.2 M acetate buffer solution (pH 5.0). As a result of the interaction of Cu(I) between the base pairs of the dsDNA, the characteristic peaks of dsDNA, due to the oxidation of guanine and adenine, increased and after a certain concentration of Cu(I) a new peak at +1.37 V appeared, probably due to the formation of a purine-Cu(I) complex (dsDNA-Cu(I) complex). Accordingly, the interaction of copper(I) with calf thymus dsDNA was studied in solution as well as at the electrode surface using hanging mercury drop electrode (HMDE) by means of alternating current voltammetry (AC voltammetry) in 0.3 M NaCl and 50 mM sodium phosphate buffer (pH 8.5) as supporting electrolyte. Its interaction with DNA is shown to be time dependent. Significant changes in the characteristic peaks of dsDNA were observed after addition of higher concentration of Cu(I) to a solution containing dsDNA, as a result of the interaction between Cu(I) and dsDNA. All the experimental results indicate that Cu(I) can bind to DNA by electrostatic binding and form an association complex.

  13. Gan-Hang tectonic belt and its geologic significance

    International Nuclear Information System (INIS)

    Deng Jiarui; Zhang Zhiping.

    1989-01-01

    Gan-Hang tectonic belt is predominantly controlled by Gan-Hang fracture zone. It is mainly composed of Yongfeng-Zhuji downwarping zone, Gan-Hang volcanic activity structural belt and Gan-Hang red basin downfaulted zone. Gan-Hang fracture zone is derived from evolution and development of Shaoxing-Jiangshan deep fracture. It is mainly composed of three deep and large fracture and Fuzhou-Yongfeng large fracture. The fracture zone is a long active belt, but in each active period the geologic structural patterns intensity, depth and forming time were not same. Gan-Hang tectonic belt possesses obvious inheritance. It has always maintained the character of the relative depression or low land since the Caledonian movement. This specific structural environment is favourable for uranium mineralization. At any rate, the formation of this uranium minerogenetic zone has been experiencing a long and complicated processes which were closely associated with long activity of Gan-Hang fracture zone

  14. Homicidal hanging masquerading as suicide

    DEFF Research Database (Denmark)

    Leth, Peter Mygind; Charles, Annie Vesterby

    1997-01-01

    Homicidal hanging is rare and presents special problems for the forensic pathologist. We report a case of homicide by hanging masquerading as suicide, in which the forensic evidence was of crucial importance. The victim was a 61 years old man, who was found in his house suspended by a rope around...

  15. Model of an Evaporating Drop Experiment

    Science.gov (United States)

    Rodriguez, Nicolas

    2017-11-01

    A computational model of an experimental procedure to measure vapor distributions surrounding sessile drops is developed to evaluate the uncertainty in the experimental results. Methanol, which is expected to have predominantly diffusive vapor transport, is chosen as a validation test for our model. The experimental process first uses a Fourier transform infrared spectrometer to measure the absorbance along lines passing through the vapor cloud. Since the measurement contains some errors, our model allows adding random noises to the computational integrated absorbance to mimic this. Then the resulting data are interpolated before passing through a computed tomography routine to generate the vapor distribution. Next, the gradients of the vapor distribution are computed along a given control volume surrounding the drop so that the diffusive flux can be evaluated as the net rate of diffusion out of the control volume. Our model of methanol evaporation shows that the accumulated errors of the whole experimental procedure affect the diffusive fluxes at different control volumes and are sensitive to how the noisy data of integrated absorbance are interpolated. This indicates the importance of investigating a variety of data fitting methods to choose which is best to present the data. Trinity University Mach Fellowship.

  16. Effects of Evaporation/Condensation on Spreading and Contact Angle of a Volatile Liquid Drop

    Science.gov (United States)

    Zhang, Nengli; Chao, David F.; Singh, Bhim S. (Technical Monitor)

    2000-01-01

    Effects of evaporation/condensation on spreading and contact angle were experimentally studied. A sessile drop of R-113 was tested at different vapor environments to determine the effects of evaporation/condensation on the evolution of contact diameter and contact angle of the drop. Condensation on the drop surface occurs at both the saturated and a nonsaturated vapor environments and promotes the spreading. When the drop is placed in the saturated vapor environment it tends to completely wetting and spreads rapidly. In a nonsaturated vapor environment, the evolution of the sessile drop is divided three stages: condensation-spreading stage, evaporation-retracting stage and rapid contracting stage. In the first stage the drop behaves as in the saturated environment. In the evaporation -retracting stage, the competition between spreading and evaporation of the drop determines the evolution characteristics of the contact diameter and the contact angle. A lower evaporation rate struggles against the spreading power to turn the drop from spreading to retracting with a continuous increase of the contact angle. The drop placed in open air has a much higher evaporation rate. The strong evaporation suppresses the spreading and accelerates the retraction of the drop with a linear decrease of the contact diameter. The contraction of the evaporating drops is gradually accelerated when the contact diameter decreases to 3 min and less till drying up, though the evaporation rate is gradually slowing down.

  17. Scaling during capillary thinning of particle-laden drops

    Science.gov (United States)

    Thete, Sumeet; Wagoner, Brayden; Basaran, Osman

    2017-11-01

    A fundamental understanding of drop formation is crucial in many applications such as ink-jet printing, microfluidic devices, and atomization. During drop formation, the about-to-form drop is connected to the fluid hanging from the nozzle via a thinning filament. Therefore, the physics of capillary thinning of filaments is key to understanding drop formation and has been thoroughly studied for pure Newtonian fluids using theory, simulations, and experiments. In some of the applications however, the forming drop and hence the thinning filament may contain solid particles. The thinning dynamics of such particle-laden filaments differs radically from that of particle-free filaments. Moreover, our understanding of filament thinning in the former case is poor compared to that in the latter case despite the growing interest in pinch-off of particle-laden filaments. In this work, we go beyond similar studies and experimentally explore the impact of solid particles on filament thinning by measuring both the radial and axial scalings in the neck region. The results are summarized in terms of a phase diagram of capillary thinning of particle-laden filaments.

  18. Superheated drop, open-quotes Bubbleclose quotes, dosimeters

    International Nuclear Information System (INIS)

    Harper, M.J.; Lindler, K.W.; Nelson, M.E.; Johnson, T.L.; Jones, C.R.; Rabovsky, J.L.; Rao, N.; Kerschner, H.F.; Reil, G.K.; Schwartz, R.B.

    1991-01-01

    Superheated Drop Dosimeters (SDD) offer a sensitive, immediate measure of the neutron dose equivalent, but their dynamic range is limited and their response varies with temperature, pressure, and vibration. They contain thousands of superheated liquid drops in a stabilizing matrix. High linear energy transfer (LET) radiation triggers vaporization of the drops into visible bubbles. If the matrix is a liquid, the bubbles slowly rise, and the number present indicates the dose rate. Dose may be measured by displacement of the matrix, or by counting the sounds of vaporization. If the matrix is a gel, the bubbles are fixed, and their number is proportional to the dose equivalent. Our research has focused on modeling and elimination of the environmental response, extension of the dynamic range, and tests and evaluations of prototype devices

  19. Inverse Leidenfrost effect: self-propelling drops on a bath

    Science.gov (United States)

    Gauthier, Anais; van der Meer, Devaraj; Lohse, Detlef; Physics of Fluids Team

    2017-11-01

    When deposited on very hot solid, volatile drops can levitate over a cushion of vapor, in the so-called Leidenfrost state. This phenomenon can also be observed on a hot bath and similarly to the solid case, drops are very mobile due to the absence of contact with the substrate that sustains them. We discuss here a situation of ``inverse Leidenfrost effect'' where room-temperature drops levitate on a liquid nitrogen pool - the vapor is generated here by the bath sustaining the relatively hot drop. We show that the drop's movement is not random: the liquid goes across the bath in straight lines, a pattern only disrupted by elastic bouncing on the edges. In addition, the drops are initially self-propelled; first at rest, they accelerate for a few seconds and reach velocities of the order of a few cm/s, before slowing down. We investigate experimentally the parameters that affect their successive acceleration and deceleration, such as the size and nature of the drops and we discuss the origin of this pattern.

  20. Suicidal hanging donors for lung transplantation

    Science.gov (United States)

    Ananiadou, Olga; Schmack, Bastian; Zych, Bartlomiej; Sabashnikov, Anton; Garcia-Saez, Diana; Mohite, Prashant; Weymann, Alexander; Mansur, Ashham; Zeriouh, Mohamed; Marczin, Nandor; De Robertis, Fabio; Simon, Andre Rüdiger; Popov, Aron-Frederik

    2018-01-01

    Abstract In the context of limited donor pool in cardiothoracic transplantation, utilization of organs from high risk donors, such as suicidal hanging donors, while ensuring safety, is under consideration. We sought to evaluate the outcomes of lung transplantations (LTx) that use organs from this group. Between January 2011 and December 2015, 265 LTx were performed at our center. Twenty-two recipients received lungs from donors after suicidal hanging (group 1). The remaining 243 transplantations were used as a control (group 2). Analysis of recipient and donor characteristics as well as outcomes was performed. No statistically significant difference was found in the donor characteristics between analyzed groups, except for higher incidence of cardiac arrest, younger age and smoking history of hanging donors (P donor cause of death is not associated with poor mid-term survival or chronic lung allograft dysfunction following transplantation. These results encourage assessment of lungs from hanging donors, and their consideration for transplantation. PMID:29620623

  1. Determination of picloram in natural waters employing sequential injection square wave voltammetry using the hanging mercury drop electrode.

    Science.gov (United States)

    Dos Santos, Luciana B O; Masini, Jorge C

    2007-05-15

    This paper describes the development of a sequential injection analysis method to automate the determination of picloram by square wave voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. To perform these tasks, an 800muL monosegment is formed, composed by 400muL of sample and 400muL of conditioning/standard solution, in medium of 0.10molL(-1) H(2)SO(4). Homogenization of the monosegment is achieved by three flow reversals. After homogenization the mixture zone is injected toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode, at a flow rate of 50muLs(-1). After a suitable delay time, the potential is scanned from -0.5 to -1.0V versus Ag/AgCl at frequency of 300Hz and pulse height of 25mV. The linear dynamic range is observed for picloram concentrations between 0.10 and 2.50mgL(-1) fitting to the linear equation I(p)=(-2.19+/-0.03)C(picloram)+(0.096+/-0.039), with R(2)=0.9996, for which the slope is given in muALmg(-1). The detection and quantification limits are 0.036 and 0.12mgL(-1), respectively. The sampling frequency is 37h(-1) when the standard addition protocol is followed, but can be increased to 41h(-1) if the protocol to obtain in-line external calibration curve is used for quantification. The method was applied for determination of picloram in spiked water samples and the accuracy was evaluated by comparison with high performance liquid chromatography using molecular absorption at 220nm for detection. No evidences of statistically significant differences between the two methods were observed.

  2. Hanging drop: an in vitro air toxic exposure model using human lung cells in 2D and 3D structures.

    Science.gov (United States)

    Liu, Faye F; Peng, Cheng; Escher, Beate I; Fantino, Emmanuelle; Giles, Cindy; Were, Stephen; Duffy, Lesley; Ng, Jack C

    2013-10-15

    Using benzene as a candidate air toxicant and A549 cells as an in vitro cell model, we have developed and validated a hanging drop (HD) air exposure system that mimics an air liquid interface exposure to the lung for periods of 1h to over 20 days. Dose response curves were highly reproducible for 2D cultures but more variable for 3D cultures. By comparing the HD exposure method with other classically used air exposure systems, we found that the HD exposure method is more sensitive, more reliable and cheaper to run than medium diffusion methods and the CULTEX(®) system. The concentration causing 50% of reduction of cell viability (EC50) for benzene, toluene, p-xylene, m-xylene and o-xylene to A549 cells for 1h exposure in the HD system were similar to previous in vitro static air exposure. Not only cell viability could be assessed but also sub lethal biological endpoints such as DNA damage and interleukin expressions. An advantage of the HD exposure system is that bioavailability and cell concentrations can be derived from published physicochemical properties using a four compartment mass balance model. The modelled cellular effect concentrations EC50cell for 1h exposure were very similar for benzene, toluene and three xylenes and ranged from 5 to 15 mmol/kgdry weight, which corresponds to the intracellular concentration of narcotic chemicals in many aquatic species, confirming the high sensitivity of this exposure method. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Media influenced imitative hanging: a report from West Bengal.

    Science.gov (United States)

    Chowdhury, A N; Brahma, A; Banerjee, S; Biswas, M K

    2007-01-01

    Media influences behaviour, especially of the young children and adolescents in various ways. The present study examined the media coverage of a judicial hanging and its immediate social effect. In a qualitative study the media coverage of a case of a judicial hanging was thoroughly discussed and the media influence, for over a period of ten weeks of the incident, in terms of suicide and copying of hanging among children, was collected and analysed. Eighteen cases were reported as an aftermath of this hanging: 1 suicide and 17 imitative hanging in children with 5 deaths. This report calls for attention that media should be cautious and responsible in presenting the news items that have potential social impact.

  4. Triggering and Energetics of a Single Drop Vapor Explosion: The Role of Entrapped Non-Condensable Gases

    Energy Technology Data Exchange (ETDEWEB)

    Hansson, Roberta Concilio [Royal Institute of Technology, Stockholm (Sweden)

    2009-11-15

    The present work pertains to a research program to study Molten Fuel-Coolant Interactions (MFCI), which may occur in a nuclear power plant during a hypothetical severe accident. Dynamics of the hot liquid (melt) droplet and the volatile liquid (coolant) were investigated in the MISTEE (Micro-Interactions in Steam Explosion Experiments) facility by performing well-controlled, externally triggered, single-droplet experiments, using a high-speed visualization system with synchronized digital cinematography and continuous X-ray radiography. The current study is concerned with the MISTEE-NCG test campaign, in which a considerable amount of non-condensable gases (NCG) are present in the film that enfolds the molten droplet. The SHARP images for the MISTEE-NCG tests were analyzed and special attention was given to the morphology (aspect ratio) and dynamics of the air/ vapor bubble, as well as the melt drop preconditioning. Energetics of the vapor explosion (conversion ratio) were also evaluated. The MISTEE.NCG tests showed two main aspects when compared to the MISTEE test series (without entrapped air). First, analysis showed that the melt preconditioning still strongly depends on the coolant subcooling. Second, in respect to the energetics, the tests consistently showed a reduced conversion ratio compared to that of the MISTEE test series

  5. Sensitive detection of cyclophosphamide using DNA-modified carbon paste, pencil graphite and hanging mercury drop electrodes.

    Science.gov (United States)

    Palaska, P; Aritzoglou, E; Girousi, S

    2007-05-15

    The interaction of cyclophosphamide (CP) with calf thymus double-stranded DNA (dsDNA) and thermally denatured single-stranded DNA (ssDNA) immobilized at the carbon paste (CPE) and pencil graphite electrodes (PGE), was studied electrochemically based on oxidation signals of guanine and adenine using differential pulse voltammetry (DPV). As a result of the interaction of CP with DNA, the voltammetric signals of guanine and adenine increased in the case of dsDNA while a slight increase was observed in ssDNA. The effect of experimental parameters such as the interaction time between CP and DNA forms and the concentration of CP, were studied using DPV with CPE and PGE. Additionally, reproducibility and detection limits were determined using both electrodes. A comparison of the analytical performance between CPE and PGE was done. Our results showed that these two different DNA biosensors could be used for the sensitive, rapid and cost effective detection of CP itself as well as of CP-DNA interaction. Furthermore, the interaction of CP with dsDNA and ssDNA was studied in solution and at the electrode surface by means of alternating current voltammetry (ACV) in 0.3M NaCl and 50mM sodium phosphate buffer (pH 8.5) supporting electrolyte, using a hanging mercury drop electrode (HMDE) as working electrode. The conclusions of this study were mainly based on tensammetric peaks I (at -1.183V) and II (-1.419V) of DNA. This study involved the interaction of CP with surface-confined and solution phase DNA where experimental parameters, such as the concentration of CP and the interaction time, were studied. By increasing the concentration of CP, an increase of peak II was observed in both ds and ssDNA, while an increase of peak I was observed only in the case of dsDNA. An overall conclusion of the study using HMDE was that the interaction of CP with surface-confined DNA significantly differed from that with solution phase DNA. The increase of peaks I and II was lower in the case of

  6. Investigation of the fragmentation of molten metals dropped into cold water

    International Nuclear Information System (INIS)

    Shiralkar, G.S.

    1976-11-01

    The physical mechanism by which small quantities of molten metal fragment extensively when dropped into a pool of cold water was investigated. Since this subject has been the focus of considerable research in the past, some of the more prominent theories are briefly discussed. Experiments were conducted dropping small solid spheres at a high temperature instead of molten metal drops, and indicate a significant difference from the latter. Several hypotheses were proposed based on the hydrodynamics of the molten drop and tested analytically. The theory that the drop fragmentation is caused by the violent release of dissolved gas from within the drop was investigated experimentally and lead to the conclusion that tin fragmentation probably does not occur in this way. It is felt that a calculation of the dynamics of the vapor film that would be expected to surround the hot drop is needed. This calculation was not performed but several suggestions and estimates have been made. It would seem that the possibility of metal fragmentation by rapid vaporization of water entrapped within the metal drop is well worth investigating

  7. Comparative Analysis of 3D Bladder Tumor Spheroids Obtained by Forced Floating and Hanging Drop Methods for Drug Screening

    Directory of Open Access Journals (Sweden)

    Robson L. F. Amaral

    2017-08-01

    Full Text Available Introduction: Cell-based assays using three-dimensional (3D cell cultures may reflect the antitumor activity of compounds more accurately, since these models reproduce the tumor microenvironment better.Methods: Here, we report a comparative analysis of cell behavior in the two most widely employed methods for 3D spheroid culture, forced floating (Ultra-low Attachment, ULA, plates, and hanging drop (HD methods, using the RT4 human bladder cancer cell line as a model. The morphology parameters and growth/metabolism of the spheroids generated were first characterized, using four different cell-seeding concentrations (0.5, 1.25, 2.5, and 3.75 × 104 cells/mL, and then, subjected to drug resistance evaluation.Results: Both methods generated spheroids with a smooth surface and round shape in a spheroidization time of about 48 h, regardless of the cell-seeding concentration used. Reduced cell growth and metabolism was observed in 3D cultures compared to two-dimensional (2D cultures. The optimal range of spheroid diameter (300–500 μm was obtained using cultures initiated with 0.5 and 1.25 × 104 cells/mL for the ULA method and 2.5 and 3.75 × 104 cells/mL for the HD method. RT4 cells cultured under 3D conditions also exhibited a higher resistance to doxorubicin (IC50 of 1.00 and 0.83 μg/mL for the ULA and HD methods, respectively compared to 2D cultures (IC50 ranging from 0.39 to 0.43.Conclusions: Comparing the results, we concluded that the forced floating method using ULA plates was considered more suitable and straightforward to generate RT4 spheroids for drug screening/cytotoxicity assays. The results presented here also contribute to the improvement in the standardization of the 3D cultures required for widespread application.

  8. Comparative Analysis of 3D Bladder Tumor Spheroids Obtained by Forced Floating and Hanging Drop Methods for Drug Screening.

    Science.gov (United States)

    Amaral, Robson L F; Miranda, Mariza; Marcato, Priscyla D; Swiech, Kamilla

    2017-01-01

    Introduction: Cell-based assays using three-dimensional (3D) cell cultures may reflect the antitumor activity of compounds more accurately, since these models reproduce the tumor microenvironment better. Methods: Here, we report a comparative analysis of cell behavior in the two most widely employed methods for 3D spheroid culture, forced floating (Ultra-low Attachment, ULA, plates), and hanging drop (HD) methods, using the RT4 human bladder cancer cell line as a model. The morphology parameters and growth/metabolism of the spheroids generated were first characterized, using four different cell-seeding concentrations (0.5, 1.25, 2.5, and 3.75 × 10 4 cells/mL), and then, subjected to drug resistance evaluation. Results: Both methods generated spheroids with a smooth surface and round shape in a spheroidization time of about 48 h, regardless of the cell-seeding concentration used. Reduced cell growth and metabolism was observed in 3D cultures compared to two-dimensional (2D) cultures. The optimal range of spheroid diameter (300-500 μm) was obtained using cultures initiated with 0.5 and 1.25 × 10 4 cells/mL for the ULA method and 2.5 and 3.75 × 10 4 cells/mL for the HD method. RT4 cells cultured under 3D conditions also exhibited a higher resistance to doxorubicin (IC 50 of 1.00 and 0.83 μg/mL for the ULA and HD methods, respectively) compared to 2D cultures (IC 50 ranging from 0.39 to 0.43). Conclusions: Comparing the results, we concluded that the forced floating method using ULA plates was considered more suitable and straightforward to generate RT4 spheroids for drug screening/cytotoxicity assays. The results presented here also contribute to the improvement in the standardization of the 3D cultures required for widespread application.

  9. Kritik Mitos Tentang “Hang Tuah” Karya Amir Hamzah

    Directory of Open Access Journals (Sweden)

    Puji Santosa

    2014-06-01

    Full Text Available This study reveals the myth criticism on rhyme "Hang Tuah", an Amir Hamzah’s work expressing Malay myth. The Malay myth found in the rhyme "Hang Tuah" is placed as a meeting place of myth criticism study which includes (1 the structure of the text, (2 figure with its ideology, (3 setting presenting the myth, (4 type of myth, (5 method the poet displays the myth, and (6 the benefit or function of myth. The six elements of the review are expected to contribute in exposing and describing the element of mythology in modern Indonesian poetry and its relevance to the present situation. It is identified that Hang Tuah has an ideology of Malay heroism loyalty able to be a resource in national character building: willing to sacrifice and resilient in defending the country's sovereignty rights. The Malay heroic myth of Hang Tuah, delivered in the form of poetic ballads, adds to the classic aesthetic value. The present benefits of Hang Tuah myth, by his heroism in getting rid of European colonization, is certainly to boost the fighting spirit in defending the rights and dignity as an independent nation, free from occupation or colonialism.  This study reveals the myth criticism on rhyme "Hang Tuah", an Amir Hamzah’s work expressing Malay myth. The Malay myth found in the rhyme "Hang Tuah" is placed as a meeting place of myth criticism study which includes (1 the structure of the text, (2 figure with its ideology, (3 setting presenting the myth, (4 type of myth, (5 method the poet displays the myth, and (6 the benefit or function of myth. The six elements of the review are expected to contribute in exposing and describing the element of mythology in modern Indonesian poetry and its relevance to the present situation. It is identified that Hang Tuah has an ideology of Malay heroism loyalty able to be a resource in national character building: willing to sacrifice and resilient in defending the country's sovereignty rights. The Malay heroic myth of Hang

  10. Impulsive shock induced single drop steam explosion visualized by high-speed x-ray radiography and photography - metallic melt

    International Nuclear Information System (INIS)

    Park, H. S.; Hansson, R. C.; Sehgal, B. R.

    2003-01-01

    Experimental investigation of fine fragmentation process during vapor explosion was conducted in a small-scale single drop system employing continuous high-speed X-ray radiography and photography. A molten tin drop of about 0.7 g at approximately 1000 .deg. C was dropped into a water pool, at temperatures ranging from 20 to 90 .deg. C, and the explosion was triggered by an external shock pulse of about 1 MPa. X-ray radiographs show that finely fragmented melt particles accelerates to the vapor bubble boundary and forms a particle shell during the period of vapor bubble expansion due to vapor explosions. From the photographs, it was possible to observe a number of counter-jets on the vapor boundary. For tests with highly subcooled coolant, local explosion due to external impulsive shock trigger initiates the stratified mode of explosion along the entire melt surface. For tests with lower subcooled coolant local explosions were initiated by an external impulsive shock trigger and by collapse of vapor/gas pocket attached on the top of the melt drop. Transient spatial distribution map of melt fragments during vapor explosion was obtained by a series of image processing and calibration tests

  11. Ligature material in hanging deaths: The neglected area in forensic examination

    Directory of Open Access Journals (Sweden)

    Vipul Namdeorao Ambade

    2015-09-01

    Full Text Available The hanging mark is the most relevant feature of hanging and its characteristics are well known in the literature. Most of the time, the ligature material is not available during autopsy examination in hanging. Hence, the features of the ligature material are not submitted to systematic analysis. However, the type and position of the knot plays an important role in the mechanism of death and autopsy findings in hanging. Out of the total hanging deaths, complete hanging was seen in 67.7% of the cases, but a typical hanging was noted in only 10.2% of the cases. The commonest type of ligature material used for ligation around the neck was nylon rope followed by odhni and jute rope. The fixed knot was noted in 64.6% of the cases and a running (slip in 21.3% of the cases. The commonest position of the knot was at nape of the neck, followed by the left side of the neck at mastoid process. The number of turns/loops of a ligature around the neck was one turn in 72.4% and two in 25.2% the hanging deaths. Most victims committed suicide by hanging in their homes, and the commonest ligature points were trees, flowed by beams and ceiling hook/fans.

  12. 3-D simulation of hanging wall effect at dam site

    Science.gov (United States)

    Zhang, L.; Xu, Y.

    2017-12-01

    Hanging wall effect is one of the near fault effects. This paper focuses on the difference of the ground motions on the hanging wall side between the footwall side of the fault at dam site considering the key factors, such as actual topography, the rupture process. For this purpose, 3-D ground motions are numerically simulated by the spectrum element method (SEM), which takes into account the physical mechanism of generation and propagation of seismic waves. With the SEM model of 548 million DOFs, excitation and propagation of seismic waves are simulated to compare the difference between the ground motion on the hanging wall side and that on the footwall side. Take Dagangshan region located in China as an example, several seismogenic finite faults with different dip angle are simulated to investigate the hanging wall effect. Furthermore, by comparing the ground motions of the receiving points, the influence of several factors on hanging wall effect is investigated, such as the dip of the fault and the fault type (strike slip fault or dip-slip fault). The peak acceleration on the hanging wall side is obviously larger than those on the footwall side, which numerically evidences the hanging wall effect. Besides, the simulation shows that only when the dip is less than 70° does the hanging wall effect deserve attention.

  13. Hanging Fatalities in Central Bangkok, Thailand: A 13-Year Retrospective Study

    Directory of Open Access Journals (Sweden)

    Nattapong Tulapunt

    2017-02-01

    Full Text Available Hanging is violent asphyxial death. The objective of this study is to assess the data of hanging cases. A descriptive-retrospective study was conducted. We studied 244 hanging cases autopsied in Forensic Division, Department of Pathology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok, Thailand, between January 2001 and December 2013. The study included 197 men (80.7% and 47 women (19.2%. Their age ranged from 14 to 93 years. Most of these cases were incomplete hanging (83.6%. Features of hanging victims, such as tongue protrusion; congestion of face; petechial hemorrhage of face, conjunctiva, and internal organs; and neck injuries, significantly correlated with complete hanging. The predominant occupation of hanging victims was in the service industry (63.1%. Suicides usually occurred in private homes or apartments (84.8%. A suicide note was found in 6.1% of cases. The most common ligature material used was nylon rope, found in 61.1% of cases. The most underlying diseases of the victims in hanging cases were tuberculosis and human immunodeficiency virus infection, 9 cases each. Blood ethanol levels of 29 cases (11.8% were detected to be higher than 150 mg%. Methamphetamine and benzodiazepine were detected in 5.3% and 3.3% of cases, respectively. This study provides comprehensive baseline data of hanging cases in central Bangkok.

  14. Non-Judicial Hanging in Guilan Province, Iran between 2011 and 2013

    Directory of Open Access Journals (Sweden)

    Vahid Monsef Kasmaee

    2014-09-01

    Full Text Available Introduction: Hanging is one of the most commonly used way to commit suicide in many countries. This method used in suicide is considered a problem in Iran too, but no clear data exists regarding hanging in different regions or the country as a whole. Because of the epidemiologic differences in non-judicial hanging in different regions, this study aimed to assess it in Gilan province, Iran between 2011 and 2013. Methods: In this cross-sectional study, profiles of hanging cases registered in Poorsina hospital in Gilan, Iran between 2011 and 2013 were evaluated. Age, sex, marital status, place of residency, level of education, occupation, history of suicide, history of clinical illness, season of suicide and hanging outcome were evaluated. Results: 59 cases of hanging (mean age 31.4 ± 13.1 years and 83.0% male were evaluated. 12 (20.34% suffered from psychological disorders, and 9 (15.2% confessed to substance abuse. 7 (11.9% had a history of suicide attempts by hanging. Hanging was significantly higher in men (p<0.001, people with an education level of less than high school diploma (p=0.02 and the unemployed (p<0.05 patients. In the end, 20 (33.9% of these attempts resulted in death. Conclusion: The results of this study showed that in 2 years, 59 cases committed suicide by hanging themselves, 33.9% of which finally died. Committing suicide by hanging was significantly more prevalent in men, people with an education level of less than high school diploma and the unemployed.

  15. In vitro culture of early secondary preantral follicles in hanging drop of ovarian cell-conditioned medium to obtain MII oocytes from outbred deer mice.

    Science.gov (United States)

    Choi, Jung Kyu; Agarwal, Pranay; He, Xiaoming

    2013-12-01

    The ovarian follicle (each contains a single oocyte) is the fundamental functional tissue unit of mammalian ovaries. In humans, it has been long held true that females are born with a maximum number of follicles (or oocytes) that are not only nonrenewable, but also undergoing degeneration with time with a sharply decreased oocyte quality after the age of ∼35. Therefore, it is of importance to isolate and bank ovarian follicles for in vitro culture to obtain fertilizable oocytes later, to preserve the fertility of professional women who may want to delay childbearing, young and unmarried women who may lose gonadal function because of exposure to environmental/occupational hazards or aggressive medical treatments, such as radiation and chemotherapy, and even endangered species and breeds. Although they contributed significantly to the understanding of follicle science and biology, most studies reported to date on this topic were done using the man-made, unnatural inbred animal species. It was found in this study that the conventional two-dimensional microliter drop and three-dimensional hanging drop (HD) methods, reported to be effective for in vitro culture of preantral follicles from inbred mice, are not directly transferrable to outbred deer mice. Therefore, a modified HD method was developed in this study to achieve a much higher (>5 times compared to the best conventional methods) percentage of developing early secondary preantral follicles from the outbred mice to the antral stage, for which, the use of an ovarian cell-conditioned medium and multiple follicles per HD were identified to be crucial. It was further found that the method for in vitro maturation of oocytes in antral follicles obtained by in vitro culture of preantral follicles could be very different from that for oocytes in antral follicles obtained by hormone stimulation in vivo. Therefore, this study should provide important guidance for establishing effective protocols of in vitro follicle

  16. Near hanging: Early intervention can save lives

    Directory of Open Access Journals (Sweden)

    Ritika Gandhi

    2011-01-01

    Full Text Available Hanging is a common method of suicide/homicide in the Indian scenario. We report three successive cases of attempted suicidal hangings seen over a period of 4 months in our intensive care wards. All of them presented gasping with poor clinical status and required immediate intubation, resuscitation, assisted ventilation and intensive care treatment. None had cervical spine injury, but one patient developed aspiration pneumonia. All the three patients received standard supportive intensive care and made full clinical recovery without any neurological deficit. We conclude that the cases of near hanging should be aggressively resuscitated and treated irrespective of dismal initial presentation. This is well supported by the excellent outcomes in our cases despite their poor initial condition.

  17. Thermal interaction for molten tin dropped into water

    Energy Technology Data Exchange (ETDEWEB)

    Arakeri, V.H.; Catton, I.; Kastenberg, W.E.; Plesset, M.S.

    1978-03-01

    Multiflash photography with extremely short duration exposure times per flash was used to observe the interaction of molten tin dropped into a water bath. Detailed photographic evidence is presented which demonstrates that transition, or nucleate boiling, is a possible triggering mechanism for vapor explosions. It was also found that the thermal constraints required to produce vapor explosions could be relaxed by introducing a stable thermal stratification within the coolant. In the present work, the threshold value of the initial tin temperature required for vapor explosion was reduced from about 500 to 343/sup 0/C.

  18. Dynamics of vapor bubbles in nitrogen tetroxide in conditions of pipeline seal failure

    International Nuclear Information System (INIS)

    Karpova, T.A.; Kolesnikov, P.M.

    1988-01-01

    A numerical study has been made of cavitation processe ocurring in liquid nitrogen tetroxide with an abrupt liquid pressure drop in a temperature range from 300 to 333 K. An influence of the initial process temperature and pressure drop on dynamics of vapor bubbles with regard for heat transfer processes and phase transition liquid-vapor has been investigated

  19. Effect of External Pressure Drop on Loop Heat Pipe Operating Temperature

    Science.gov (United States)

    Jentung, Ku; Ottenstein, Laura; Rogers, Paul; Cheung, Kwok; Obenschain, Arthur F. (Technical Monitor)

    2002-01-01

    This paper discusses the effect of the pressure drop on the operating temperature in a loop heat pipe (LHP). Because the evaporator and the compensation chamber (CC) both contain two-phase fluid, a thermodynamic constraint exists between the temperature difference and the pressure drop for these two components. As the pressure drop increases, so will the temperature difference. The temperature difference in turn causes an increase of the heat leak from the evaporator to the CC, resulting in a higher CC temperature. Furthermore, the heat leak strongly depends on the vapor void fraction inside the evaporator core. Tests were conducted by installing a valve on the vapor line so as to vary the pressure drop, and by charging the LHP with various amounts of fluid. Test results verify that the LHP operating temperature increases with an increasing differential pressure, and the temperature increase is a strong function of the fluid inventory in the loop.

  20. D.R.O.P: The Durable Reconnaissance and Observation Platform

    Science.gov (United States)

    McKenzie, Clifford; Parness, Aaron

    2011-01-01

    Robots can provide a remote presence in areas that are either inaccessible or too dangerous for humans. However, robots are often limited by their ability to adapt to the terrain or resist environmental factors. The Durable Reconnaissance and Observation Platform (DROP) is a lightweight robot that addresses these challenges with the capability to survive falls from significant heights, carry a useable payload, and traverse a variety of surfaces, including climbing vertical surfaces like wood, stone, and concrete. DROP is manufactured using a combination of rapid prototyping and shape deposition manufacturing. It uses microspine technology to create a new wheel-like design for vertical climbing. To date, DROP has successfully engaged several vertical surfaces, hanging statically without assistance, and traversed horizontal surfaces at approximately 30 cm/s. Unassisted vertical climbing is capable on surfaces up to 85deg at a rate of approximately 25cm*s(sup -1). DROP can also survive falls from up to 3 meters and has the ability to be thrown off of and onto rooftops. Future efforts will focus on improving the microspine wheels, selecting more resilient materials, customizing the controls, and performing more rigorous and quantifiable testing.

  1. Acute pulmonary emphysema in death by hanging: a morphometric digital study.

    Science.gov (United States)

    Castiglioni, Claudia; Baumann, Pia; Fracasso, Tony

    2016-09-01

    Acute pulmonary emphysema (APE) has been described in cases of mechanical asphyxia such as ligature or manual strangulation but not in cases of hanging. In this study, we wanted to verify by morphometric digital analysis of lung tissue whether APE occurs in death by hanging.We investigated 16 cases of hanging (eight complete, eight incomplete), 10 cases of freshwater drowning (positive control group), and 10 cases of acute external bleeding (negative control group). Tissue sections were obtained from each pulmonary lobe. For each slide, five fields were randomly selected. The area of every alveolar space was measured by image analysis software. The mean alveolar area (MAA) was calculated for each group.In incomplete hanging, MAA was significantly higher than that observed in complete hanging and similar to the one observed in freshwater drowning.APE in cases of incomplete hanging can be considered as a sign of vitality. The high number of conditions that can cause alveolar distension (that were excluded in this study) limits the applicability of this vital sign in the routine forensic practice.

  2. Hanging-induced burst suppression pattern in EEG

    Directory of Open Access Journals (Sweden)

    Nilgun Cinar

    2012-01-01

    Full Text Available Lethal suspension (hanging is one of the most common methods of attempting suicide. Spinal fractures, cognitive and motor deficits as well as epileptic seizures can be detected after unsuccessful hanging attempts. Introduced here is the case of a 25-year-old man exemplifying the clinical observations stated hereafter, who was conveyed to our emergency room after having survived attempted suicide by hanging, with his post-anoxic burst-suppression electroencephalography (BS-EEG pattern and clinical diagnoses in the post-comatose stage. The patient′s state of consciousness was gradually improved over a period of time. His neuropsychiatric assessment proved that memory deficit, a slight lack of attention and minor executive dysfunction was observed a month after the patient was discharged. Although the BS-EEG pattern indicates severe brain dysfunction, it is a poor prognostic factor; rarely, patients survive with minor cognitive deficits and can perform their normal daily activities.

  3. The discovery and exploration of Hang Son Doong

    Energy Technology Data Exchange (ETDEWEB)

    Limbert, H.; Limbert, D.; Hieu, N.; Phai, V. V.; Kinh Bac, D.; Phuong, T. H.; Granger, D.

    2016-08-01

    Hang Son Doong is located in the Phong Nha Ke Bang Limestone Massif in Quang Binh Province, Central Vietnam. Cave exploration by British cavers has been continuous in this area since 1990. Hang Son Doong is part of the Phong Nha Cave system which runs from the southern end of the National Park near the Lao border to the final resurgence at Phong Nha Cave. (Author)

  4. Crystallization and X-ray analysis of the salmon-egg lectin SEL24K

    Energy Technology Data Exchange (ETDEWEB)

    Murata, Kenji [Department of Animal Science, University of California, Davis 95616 (United States); Fisher, Andrew J. [Department of Chemistry, University of California, Davis 95616 (United States); Hedrick, Jerry L., E-mail: jlhedrick@ucdavis.edu [Department of Animal Science, University of California, Davis 95616 (United States)

    2007-05-01

    The 24 kDa egg lectin of Chinook salmon (Oncorhynchus tshawytscha) was purified by affinity chromatography from salmon eggs and crystallized by the hanging-drop vapor-diffusion method using 15/4 EO/OH (pentaerythritol ethoxylate) as a precipitant. The 24 kDa egg lectin of Chinook salmon (Oncorhynchus tshawytscha) is released from the egg during the cortical reaction. The lectin functions in blocking polyspermy during the fertilization process. The egg lectin was purified by affinity chromatography from salmon eggs and crystallized by the hanging-drop vapor-diffusion method using 15/4 EO/OH (pentaerythritol ethoxylate) as a precipitant. The crystal diffracted synchrotron-radiation X-rays to 1.63 Å resolution. The crystal belongs to the monoclinic space group P2{sub 1}, with unit-cell parameters a = 93.0, b = 73.6, c = 113.6 Å, α = 90, β = 92.82, γ = 90°. The crystal is likely to contain eight molecules in the asymmetric unit (V{sub M} = 2.3 Å{sup 3} Da{sup −1}), corresponding to a solvent content of 45.5%. A self-rotation function suggests an arrangement with 222 point symmetry within the asymmetric unit.

  5. Length of a Hanging Cable

    Directory of Open Access Journals (Sweden)

    Eric Costello

    2011-01-01

    Full Text Available The shape of a cable hanging under its own weight and uniform horizontal tension between two power poles is a catenary. The catenary is a curve which has an equation defined by a hyperbolic cosine function and a scaling factor. The scaling factor for power cables hanging under their own weight is equal to the horizontal tension on the cable divided by the weight of the cable. Both of these values are unknown for this problem. Newton's method was used to approximate the scaling factor and the arc length function to determine the length of the cable. A script was written using the Python programming language in order to quickly perform several iterations of Newton's method to get a good approximation for the scaling factor.

  6. Photoassisted vapor generation in the presence of organic acids for ultrasensitive determination of Se by electrothermal-atomic absorption spectrometry following headspace single-drop microextraction

    International Nuclear Information System (INIS)

    Figueroa, Raul; Garcia, Monica; Lavilla, Isela; Bendicho, Carlos

    2005-01-01

    A method is described for the determination of selenium at the pg/mL level by electrothermal-atomic absorption spectrometry using in situ photogeneration of Se vapors, headspace sequestration onto an aqueous microdrop containing Pd(II) and subsequent injection in a graphite tube. Several organic acids (formic, oxalic, acetic, citric and ethylenediaminetetraacetic) have been tried for photoreduction of Se(IV) into volatile Se compounds under UV irradiation. Experimental variables such as UV irradiation time, organic acid concentration, Pd(II) concentration in the drop, sample and drop volumes, extraction time and pH were fully optimized. Low-molecular weight acids such as formic and acetic provided optimal photogeneration of volatile Se species at a 0.6 mol/L concentration. Citric and ethylenediaminetetraacetic acid allowed to use a concentration as low as 1 mmol/L, but extraction times were longer than for formic and acetic acids. Photogeneration of (CH 3 ) 2 Se from Se(IV) in the presence of acetic acid provided a detection limit of 20 pg/mL, a preconcentration factor of nearly 285 and a precision, expressed as relative standard deviation, of 4%. Analytical performance seemed to depend not only on the photogeneration efficiency obtained with each acid but also on the stability of the vapors in the headspace. The method showed a high freedom from interferences caused by saline matrices, but interferences were observed for transition metals at a relatively low concentration

  7. Wetting and evaporation of binary mixture drops.

    Science.gov (United States)

    Sefiane, Khellil; David, Samuel; Shanahan, Martin E R

    2008-09-11

    Experimental results on the wetting behavior of water, methanol, and binary mixture sessile drops on a smooth, polymer-coated substrate are reported. The wetting behavior of evaporating water/methanol drops was also studied in a water-saturated environment. Drop parameters (contact angle, shape, and volume) were monitored in time. The effects of the initial relative concentrations on subsequent evaporation and wetting dynamics were investigated. Physical mechanisms responsible for the various types of wetting behavior during different stages are proposed and discussed. Competition between evaporation and hydrodynamic flow are evoked. Using an environment saturated with water vapor allowed further exploration of the controlling mechanisms and underlying processes. Wetting stages attributed to differential evaporation of methanol were identified. Methanol, the more volatile component, evaporates predominantly in the initial stage. The data, however, suggest that a small proportion of methanol remained in the drop after the first stage of evaporation. This residual methanol within the drop seems to influence subsequent wetting behavior strongly.

  8. Craniocervical injuries in judicial hangings: an anthropologic analysis of six cases.

    Science.gov (United States)

    Spence, M W; Shkrum, M J; Ariss, A; Regan, J

    1999-12-01

    Restoration projects and archaeologic excavations in two Canadian prisons resulted in the recovery of the skeletons of six felons executed by judicial hanging. Damage inflicted by hanging on various skeletal elements was observed. Among the injuries seen were fractures of the hyoid cornua, styloid processes, occipital bones, and cervical vertebral bodies (C2) and transverse processes (C1, C2, C3, and C5). Despite the general uniformity of the hanging technique, which involved a subaural knot, the trauma to the skeletal elements and the cause of death varied among individuals. Although some of this variation was probably due to minor differences in hanging practices, individual anatomic peculiarities of the victims likely also contributed.

  9. Understanding water equilibration fundamentals as a step for rational protein crystallization.

    Directory of Open Access Journals (Sweden)

    Pedro M Martins

    Full Text Available BACKGROUND: Vapor diffusion is the most widely used technique for protein crystallization and the rate of water evaporation plays a key role on the quality of the crystals. Attempts have been made in the past to solve the mass transfer problem governing the evaporation process, either analytically or by employing numerical methods. Despite these efforts, the methods used for protein crystallization remain based on trial and error techniques rather than on fundamental principles. METHODOLOGY/PRINCIPAL FINDINGS: Here we present a new theoretical model which describes the hanging drop method as a function of the different variables that are known to influence the evaporation process. The model is extensively tested against experimental data published by other authors and considering different crystallizing conditions. Aspects responsible for the discrepancies between the existing theories and the measured evaporation kinetics are especially discussed; they include the characterization of vapor-liquid equilibrium, the role of mass transfer within the evaporating droplet, and the influence of the droplet-reservoir distance. CONCLUSIONS/SIGNIFICANCE: The validation tests show that the proposed model can be used to predict the water evaporation rates under a wide range of experimental conditions used in the hanging drop vapor-diffusion method, with no parameter fitting or computational requirements. This model combined with protein solubility data is expected to become a useful tool for a priori screening of crystallization conditions.

  10. R-22 vapor explosions

    International Nuclear Information System (INIS)

    Anderson, R.P.; Armstrong, D.R.

    1977-01-01

    Previous experimental and theoretical studies of R-22 vapor explosions are reviewed. Results from two experimental investigations of vapor explosions in a medium scale R-22/water system are reported. Measurements following the drop of an unrestrained mass of R-22 into a water tank demonstrated the existence of two types of interaction behavior. Release of a constrained mass of R-22 beneath the surface of a water tank improved the visual resolution of the system thus allowing identification of two interaction mechansims: at low water temperatures, R-22/water contact would produce immediate violent boiling; at high water temperatures a vapor film formed around its R-22 as it was released, explosions were generated by a surface wave which initiated at a single location and propagated along the vapor film as a shock wave. A new vapor explosion model is proposed, it suggests explosions are the result of a sequence of three independent steps: an initial mixing phase, a trigger and growth phase, and a mature phase where a propagating shock wave accelerates the two liquids into a collapsing vapor layer causing a high velocity impact which finely fragments and intermixes the two liquids

  11. Behaviour and quantification studies of terbacil and lenacil in environmental samples using cyclic and adsorptive stripping voltammetry at hanging mercury drop electrode.

    Science.gov (United States)

    Thriveni, T; Rajesh Kumar, J; Sujatha, D; Sreedhar, N Y

    2007-05-01

    The cyclic voltammograms of terbacil and lenacil at the hanging mercury drop electrode showed a single well defined four electron irreversible peak in universal buffer of pH 4.0 for both compounds. The peak potentials were shifted to more negative values on the increase of pH of the medium, implying the involvement of protons in the electrode reaction and that the proton transfer reaction precedes the proper electrode process. The four electron single peak may be attributed to the simultaneous reduction of carbonyl groups present in 2 and 4 in pyrimidine ring of terbacil and lenacil to the corresponding hydroxy derivative. Based on the interfacial adsorptive character of the terbacil and lenacil onto the mercury electrode surface, a simple sensitive and low cost differential pulse adsorptive stripping voltammetric procedure was optimized for the analysis of terbacil and lenacil. The optimal operational conditions of the proposed procedure were accumulation potential E (acc) = -0.4 V, accumulation time t (acc) = 80 s, scan rate = 40 mV s(-1), pulse amplitude = 25 mV using a universal buffer pH 4.0 as a supporting electrolyte. The linear concentration range was found to be 1.5 x 10(-5) to 1.2 x 10(-9) mol/l and 1.5 x 10(-5) to 2.5 x 10(-8) mol/l with the lower detection limit of 1.22 x 10(-9) and 2.0 x 10(-8) mol/l. The correlation coefficient and relative standard deviation values are found to be 0.942, 0.996, 1.64% and 1.23%, respectively, for 10 replicants. The procedure was successfully applied for determination of terbacil and lenacil in formulations, mixed formulations, environmental samples such as fruit samples and spiked water samples.

  12. Development of a sequential injection-square wave voltammetry method for determination of paraquat in water samples employing the hanging mercury drop electrode.

    Science.gov (United States)

    dos Santos, Luciana B O; Infante, Carlos M C; Masini, Jorge C

    2010-03-01

    This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 µL s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), µA) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): i(p) = (-20.5 ± 0.3)C (paraquat) - (0.02 ± 0.03). The limits of detection and quantification were 2.0 and 7.0 µg L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.

  13. Thermodynamics of adsorption of dithiocarbamates at the hanging mercury drop.

    Science.gov (United States)

    Giannakopoulos, Evangelos; Deligiannakis, Yiannis

    2007-02-27

    Two dimethyldithiocarbamate (DMDTC) pesticides, thiram and ziram, are adsorbed onto a Hg drop via an entropically driven process. The adsorption isotherms are described by the Frumkin equation. For both molecules, the adsorption is characterized by a nonlinear pseudosigmoid temperature dependence of the Gibbs free energy. For the temperature range of 273-313 K, DeltaGADS varies between -43.4 and -56.71 kJ/mol for thiram and -42.60 and -55.67 kJ/mol for ziram. This variation of DeltaGADS reveals that the adsorption strength is increased at higher temperatures. During the adsorption of either molecule, strong lateral interactions are developed between neighboring adsorbates, which are severely weakened as the temperature increases. A unified reaction scheme is suggested for both ziram and thiram that predicts the formation and adsorption of a surface complex, (DMDTC)2Hg. In the case of thiram, two DMDTC molecules are formed by the cleavage of the disulfide S-S bond near the Hg electrode. The thermodynamic and structural parameters reveal that there are two limiting thermodynamic regimes for the adsorbed (DMDTC)2Hg species that originate from two limiting adsorption conformations of the adsorbates on the Hg surface. A transition occurs between these two conformations at temperatures in the region of 285-295 K. This transition is accompanied by large entropic and enthalpic changes.

  14. Headspace liquid-phase microextraction of methamphetamine and amphetamine in urine by an aqueous drop

    International Nuclear Information System (INIS)

    He Yi; Vargas, Angelica; Kang, Youn-Jung

    2007-01-01

    This study developed a headspace liquid-phase microextraction (LPME) method by using a single aqueous drop in combination with high performance liquid chromatography (HPLC)-UV detection for the determination of methamphetamine (MAP) and amphetamine (AP) in urine samples. The analytes, volatile and basic, were released from sample matrix into the headspace first, and then protonated and dissolved in an aqueous H 3 PO 4 drop hanging in the headspace by a HPLC syringe. After extraction, this drop was directly injected into HPLC. Parameters affecting extraction efficiency were investigated and optimized. This method showed good linearity in the investigated concentration range of 1.0-1500 μg L -1 , repeatability of the extraction (R.S.D. -1 for both analytes). Enrichment factors of about 400-fold and 220-fold were achieved for MAP and AP, respectively, at optimum conditions. The feasibility of the method was demonstrated by analyzing human urine samples

  15. SUICIDAL HANGING IN URBAN YOUTH : A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Bhola Kumar Singh

    2015-02-01

    Full Text Available BACKGROUND : Suicide is among the top three causes of death among youth worldwide. Hanging is among the most common modes of suicide. OBJECTIVES: The purpose of this prospective study is to determine the Suicidal hanging in urban youth and determine the prevalence of suicidal hanging in our community. METHODS : In this descriptive, prospective, cross sectional study, all patients who pres ented to the department of emergency medicine with suicidal hanging during this study period of 12 months from January 2010 - December 2011 in . were included. RESULTS : Total number of males in the study is 32 (64%, females in the study is 18(36%. Mean age of the you th was 22.50± 8.15(SD years, Male 18.50± 12.15(SD years, Females 20.50 ±5.25(SD years; predominantly the patients were in the age group of 22 - 26 years. Number of male smokers in the study was 26 (81.25% female smokers were 4(22.22%, number of m ale alcoholics were 27(84.37% whereas female alcoholics were 6(33.33%, number of patients with pallor in males were 16(50% whereas females with pallor were 12(66.66%, number of males with skin changes were 6(18.75% when compared to females who had 8(4 4.44% skin changes, number of males wit oedema were 4(12.5% and 6(33.33% of females had oedema, the mean weight among males were 48±8.34kgs when compared to females which was 42±6.56kgs. Most of the patients who attempted suicide had varied personality issues from mood disorders to psychosis. CONCLUSION : There is significant percentage of patients who attempt suicide by hanging

  16. Experimental study on condensation heat transfer enhancement and pressure drop penalty factors in four microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Han, D [Korea University, Seoul (Korea). Institute of Advanced Machinery Design; Lee, Kyu-Jung [Korea University, Seoul (Korea). Dept. of Mechanical Engineering

    2005-08-01

    Heat transfer and pressure drop characteristics of four microfin tubes were experimentally investigated for condensation of refrigerants R134a, R22, and R410A in four different test sections. The microfin tubes examined during this study consisted of 8.92, 6.46, 5.1, and 4 mm maximum inside diameter. The effect of mass flux, vapor quality, and refrigerants on condensation was investigated in terms of the heat transfer enhancement factor and the pressure drop penalty factor. The pressure drop penalty factor and the heat transfer enhancement factor showed a similar tendency for each tube at given vapor quality and mass flux. Based on the experimental data and the heat-momentum analogy, correlations for the condensation heat transfer coefficients in an annular flow regime and the frictional pressure drops are proposed. (author)

  17. Investigating the effects of water vaporization on the production of ...

    African Journals Online (AJOL)

    The simulations show that water vaporization increases productivity of well by increasing gas saturation and relative permeability near the well walls and improving the mobility of gas; and this effect is stronger in rich gas condensate reservoir than the lean ones. Keywords: Well, Gas, Pressure Drop, Vapor pressure of water ...

  18. Sistem Informasi Akademik pada SMA Swasta Hang Tuah Belawan

    OpenAIRE

    Syarifuddin, Ruisya

    2015-01-01

    Perancangan Sistem Informasi Akademik pada SMA Swasta Hang Tuah Belawan ini bertujuan untuk mempermudah proses pencarian atau searching data dan informasi untuk seluruh Siswa SMA Swasta Hang Tuah Belawan yang mengalami kesulitan dalam memperoleh data mengenai masalah Akademik tersebut. Faasilitas yang terdapat dalam aplikasi ini berupa penyediaan data dan informasi mengenai beritaberita terbaru, profil agenda kegiatan, dan data-data yang berguna untuk kelangsungan belajar si...

  19. Headspace liquid-phase microextraction of methamphetamine and amphetamine in urine by an aqueous drop

    Energy Technology Data Exchange (ETDEWEB)

    He Yi [Department of Sciences, John Jay College of Criminal Justice, City University of New York, 445 W 59th Street, New York, NY 10019 (United States)]. E-mail: yhe@jjay.cuny.edu; Vargas, Angelica [Department of Sciences, John Jay College of Criminal Justice, City University of New York, 445 W 59th Street, New York, NY 10019 (United States); Kang, Youn-Jung [Department of Sciences, John Jay College of Criminal Justice, City University of New York, 445 W 59th Street, New York, NY 10019 (United States)

    2007-04-25

    This study developed a headspace liquid-phase microextraction (LPME) method by using a single aqueous drop in combination with high performance liquid chromatography (HPLC)-UV detection for the determination of methamphetamine (MAP) and amphetamine (AP) in urine samples. The analytes, volatile and basic, were released from sample matrix into the headspace first, and then protonated and dissolved in an aqueous H{sub 3}PO{sub 4} drop hanging in the headspace by a HPLC syringe. After extraction, this drop was directly injected into HPLC. Parameters affecting extraction efficiency were investigated and optimized. This method showed good linearity in the investigated concentration range of 1.0-1500 {mu}g L{sup -1}, repeatability of the extraction (R.S.D. < 5%, n = 6), and low detection limits (0.3 {mu}g L{sup -1} for both analytes). Enrichment factors of about 400-fold and 220-fold were achieved for MAP and AP, respectively, at optimum conditions. The feasibility of the method was demonstrated by analyzing human urine samples.

  20. Hanging Out with Which Friends? Friendship-Level Predictors of Unstructured and Unsupervised Socializing in Adolescence

    Science.gov (United States)

    Siennick, Sonja E.; Osgood, D. Wayne

    2012-01-01

    Companions are central to explanations of the risky nature of unstructured and unsupervised socializing, yet we know little about whom adolescents are with when hanging out. We examine predictors of how often friendship dyads hang out via multilevel analyses of longitudinal friendship-level data on over 5,000 middle schoolers. Adolescents hang out most with their most available friends and their most generally similar friends, not with their most at-risk or similarly at-risk friends. These findings vary little by gender and wave. Together, the findings suggest that the risks of hanging out stem from the nature of hanging out as an activity, not the nature of adolescents’ companions, and that hanging out is a context for friends’ mutual reinforcement of pre-existing characteristics. PMID:23204811

  1. Hanging Out with Which Friends? Friendship-Level Predictors of Unstructured and Unsupervised Socializing in Adolescence.

    Science.gov (United States)

    Siennick, Sonja E; Osgood, D Wayne

    2012-12-01

    Companions are central to explanations of the risky nature of unstructured and unsupervised socializing, yet we know little about whom adolescents are with when hanging out. We examine predictors of how often friendship dyads hang out via multilevel analyses of longitudinal friendship-level data on over 5,000 middle schoolers. Adolescents hang out most with their most available friends and their most generally similar friends, not with their most at-risk or similarly at-risk friends. These findings vary little by gender and wave. Together, the findings suggest that the risks of hanging out stem from the nature of hanging out as an activity, not the nature of adolescents' companions, and that hanging out is a context for friends' mutual reinforcement of pre-existing characteristics.

  2. The epidemiology of injury in hang-gliding and paragliding.

    Science.gov (United States)

    Rekand, Tiina

    2012-01-01

    Para- and hang-gliding are modern air sports that developed in the 20th century. Performers should possess technical skills and manage certified equipment for successful flight. Injuries may happen during the take-off, flight and landing. PubMed was searched using the search terms 'paragliding' and/or 'hang-gliding'. The reference lists of articles identified in the search strategy were also searched for relevant articles. The most common injuries are fractures, dislocations or sprains in the extremities, followed by spinal and head traumas. Multiple injuries after accidents are common. Collision with electrical wires may cause burn injuries. Fatal outcomes are caused by brain injuries, spinal cord injuries at the cervical level or aorta rupture. Accidents happen because of risk-taking behavior, lack of education or use of self-modified equipment. Observational studies have suggested the need for protection of the head, trunk and lower extremities. The measures proposed are often based on conclusions of observational studies and not proven through randomized studies. Better education along with focusing on possible risk factors will probably diminish the risks of hang- and paragliding. Large denominator-based case series, case-control and population-based studies are needed for assessment of the risks of hang- and paragliding. Copyright © 2012 S. Karger AG, Basel.

  3. Droplet Vaporization In A Levitating Acoustic Field

    Science.gov (United States)

    Ruff, G. A.; Liu, S.; Ciobanescu, I.

    2003-01-01

    Combustion experiments using arrays of droplets seek to provide a link between single droplet combustion phenomena and the behavior of complex spray combustion systems. Both single droplet and droplet array studies have been conducted in microgravity to better isolate the droplet interaction phenomena and eliminate or reduce the effects of buoyancy-induced convection. In most experiments involving droplet arrays, the droplets are supported on fibers to keep them stationary and close together before the combustion event. The presence of the fiber, however, disturbs the combustion process by introducing a source of heat transfer and asymmetry into the configuration. As the number of drops in a droplet array increases, supporting the drops on fibers becomes less practical because of the cumulative effect of the fibers on the combustion process. To eliminate the effect of the fiber, several researchers have conducted microgravity experiments using unsupported droplets. Jackson and Avedisian investigated single, unsupported drops while Nomura et al. studied droplet clouds formed by a condensation technique. The overall objective of this research is to extend the study of unsupported drops by investigating the combustion of well-characterized drop clusters in a microgravity environment. Direct experimental observations and measurements of the combustion of droplet clusters would provide unique experimental data for the verification and improvement of spray combustion models. In this work, the formation of drop clusters is precisely controlled using an acoustic levitation system so that dilute, as well as dense clusters can be created and stabilized before combustion in microgravity is begun. While the low-gravity test facility is being completed, tests have been conducted in 1-g to characterize the effect of the acoustic field on the vaporization of single and multiple droplets. This is important because in the combustion experiment, the droplets will be formed and

  4. Realization methodology for optimal design of steel structures conveyors with hanging belt

    Directory of Open Access Journals (Sweden)

    Boslovyak P.V.

    2016-03-01

    Full Text Available Presents the results of optimum design of metal structures of the fixed conveyor with hanging belt. The analysis results optimum design of steel structures of stationary conveyor with hanging belt.

  5. Effects of molten material temperatures and coolant temperatures on vapor explosion

    Institute of Scientific and Technical Information of China (English)

    LI Tianshu; YANG Yanhua; YUAN Minghao; HU Zhihua

    2007-01-01

    An observable experiment facility for low-temperature molten materials to be dropped into water was set up in this study to investigate the mechanism of the vapor explosion. The effect of the fuel and coolant interaction(FCI) on the vapor explosion during the severe accidents of a fission nuclear reactor has been studied. The experiment results showed that the molten material temperature has an important effect on the vapor explosion behavior and pressure. The increase of the coolant temperature would decrease the pressure of the vapor explosion.

  6. Linkage between canopy water storage and drop size distributions of leaf drips

    Science.gov (United States)

    Nanko, Kazuki; Watanabe, Ai; Hotta, Norifumi; Suzuki, Masakazu

    2013-04-01

    Differences in drop size distribution (DSD) of leaf drips among tree species have been estimated and physically interpreted to clarify the leaf drip generation process. Leaf drip generation experiments for nine species were conducted in an indoor location without foliage vibration using an automatic mist spray. Broad-leaved species produced a similar DSD among species whose leaves had a matte surface and a second similar DSD among species whose leaves had a coated surface. The matte broad leaves produced a larger and wider range of DSDs than the coated broad leaves. Coated coniferous needles had a wider range of DSDs than the coated broad leaves and different DSDs were observed for different species. The species with shorter dense needles generated a larger DSD. The leaf drip diameter was calculated through the estimation of a state of equilibrium of a hanging drop on the leaves based on physical theory. The calculations indicated that the maximum diameter of leaf drips was determined by the contact angle, and the range of DSDs was determined by the variation in contact length and the contact diameter at the hanging points. The results revealed that leaf drip DSD changed due to variations in leaf hydrophobicity, leaf roughness, leaf geometry and leaf inclination among the different tree species. This study allows the modelization of throughfall DSD. Furthermore, it indicates the possibility of interpreting canopy water processes from canopy water storage to drainage through the contact angle and leaf drip DSD. The part of this study is published in Nanko et al. (2013, Agric. Forest. Meteorol. 169, 74-84).

  7. Analysis of the fragmentation of hot drops with film boiling in a water flow

    International Nuclear Information System (INIS)

    Malmazet, Erik de

    2009-01-01

    The goal of this work is to study different aspects of the fragmentation of very hot drops placed in a uniform flow, a phenomenon related to vapor explosion studies. First, a theoretical study of the isothermal hydrodynamic fragmentation of drops by the Boundary Layer Stripping (BLS) mechanism is done by developing two models. The first model, contrary to past studies which dismissed the BLS, includes deformation and acceleration effects and this is shown to greatly enhance the mass loss by BLS, which enables this mechanism to become a much more effective mechanism when the external flow is gaseous. But it is still ineffective in the liquid case. The second model describes transient aspects of the BLS, and by coupling it with a stripping criteria for the internal boundary layer, it is possible to predict the time of the initiation of fragmentation. Then, a model for film boiling over horizontal cylinders and axisymmetric bodies which is able to properly describe the inertial and convection terms in the vapor flow is presented. This has never been done before, although these terms cannot be neglected in physical conditions close to vapor explosions. The model is able to predict all the experimental results of TREPAM, the only existing forced convection film boiling experiment in conditions close to a vapor explosion, and which results could not be predicted by other models. In the last part, an experimental study of the fragmentation of hot tin drops in a water flow which uses digital fast camera and flash X ray imagery is presented. This study has allowed the observation of several new features of the drop fragmentation mechanism. (author) [fr

  8. Structure and Dynamics of Interfaces: Drops and Films

    Science.gov (United States)

    Mann, J. Adin, Jr.; Mann, Elizabeth K.; Meyer, William V.; Neumann, A. Wilhelm; Tavana, Hossein

    2015-01-01

    We aim to acquire measurements of the structure and dynamics of certain liquid-fluid interfaces using an ensemble of techniques in collaboration: (1) Total internal reflection (TIR) Surface light scattering spectroscopy (SLSS), (2) Brewster angle microscopy (BAM), and (3) Drop-shape analysis. SLSS and BAM can be done on a shared interfacial footprint. Results using a 50-50 mixture of pentane-isohexane, which extends the range of NASA's Confined Vapor Bubble (CVB) experiment, yield surface tension results that differ from the expected Langmuir Fit. These results were confirmed using both the SLSS and drop-shape analysis approaches.

  9. Flow condensation pressure drop characteristics of R410A-oil mixture inside small diameter horizontal microfin tubes

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xiangchao; Ding, Guoliang; Hu, Haitao; Zhu, Yu [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Gao, Yifeng [International Copper Association Shanghai Office, Shanghai 200020 (China); Deng, Bin [Institute of Heat Transfer Technology, Golden Dragon Precise Copper Tube Group Inc., Shanghai 200135 (China)

    2010-11-15

    Flow condensation pressure drop characteristics of R410A-oil mixture inside small diameter (5.0 mm and 4.0 mm O.D.) horizontal microfin tubes were investigated experimentally covering nominal oil concentrations from 0% to 5%. The research results indicate that, comparing with the frictional pressure drop of pure R410A, the frictional pressure drop of R410A-oil mixture may decrease by maximum of 18% when the vapor quality is lower than 0.6, and increase by maximum of 13% when the vapor quality is higher than 0.6. A new frictional pressure drop correlation for R410A-oil mixture flow condensation inside microfin tubes is developed based on the refrigerant-oil mixture properties, and can agree with 94% of the experimental data within a deviation of -30% to +30%. (author)

  10. Fate of sulfur mustard on soil: Evaporation, degradation, and vapor emission.

    Science.gov (United States)

    Jung, Hyunsook; Kah, Dongha; Chan Lim, Kyoung; Lee, Jin Young

    2017-01-01

    After application of sulfur mustard to the soil surface, its possible fate via evaporation, degradation following absorption, and vapor emission after decontamination was studied. We used a laboratory-sized wind tunnel, thermal desorber, gas chromatograph-mass spectrometry (GC-MS), and 13 C nuclear magnetic resonance ( 13 C NMR) for systematic analysis. When a drop of neat HD was deposited on the soil surface, it evaporated slowly while being absorbed immediately into the matrix. The initial evaporation or drying rates of the HD drop were found to be power-dependent on temperature and initial drop volume. Moreover, drops of neat HD, ranging in size from 1 to 6 μL, applied to soil, evaporated at different rates, with the smaller drops evaporating relatively quicker. HD absorbed into soil remained for a month, degrading eventually to nontoxic thiodiglycol via hydrolysis through the formation of sulfonium ions. Finally, a vapor emission test was performed for HD contaminant after a decontamination process, the results of which suggest potential risk from the release of trace chemical quantities of HD into the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Visualization study of film drops produced by bubble bursting

    International Nuclear Information System (INIS)

    Ma Chao; Bo Hanliang

    2012-01-01

    The phenomenon that bubble bursting results in drops production is common in the steam generator of the nuclear power plant, and the fine drops generated by this way is one of the most important source of the drop entrainment in the vapor stream. The visualization experiment about the film drops produced by the bursting bubbles at a free water surface was studied using a high-speed video camera. The results show that the bubble cap breaks up in a single point, within the limits of bubble size in the experiment at present. The whole process can be distinguished into four successive stages: A primary inertial drainage, the bubble cap puncture at the foot or on the top, the film rolls-up and the liquid ring appearing with the hole expanding, and fine film drops emission under the effect of destabilization of a Rayleigh-Taylor type. The expression about the bubble radius and the film drops number is obtain by fitting the experiment data at the bubble radius range from 3-25 mm. The result trend agrees well with the previous work. (authors)

  12. Formation of microbeads during vapor explosions of Field's metal in water

    KAUST Repository

    Kouraytem, Nadia

    2016-06-17

    We use high-speed video imaging to investigate vapor explosions during the impact of a molten Field\\'s metal drop onto a pool of water. These explosions occur for temperatures above the Leidenfrost temperature and are observed to occur in up to three stages as the metal temperature is increased, with each explosion being more powerful that the preceding one. The Field\\'s metal drop breaks up into numerous microbeads with an exponential size distribution, in contrast to tin droplets where the vapor explosion deforms the metal to form porous solid structures. We compare the characteristic bead size to the wavelength of the fastest growing mode of the Rayleigh-Taylor instability.

  13. Formation of microbeads during vapor explosions of Field's metal in water

    KAUST Repository

    Kouraytem, Nadia; Li, Erqiang; Thoroddsen, Sigurdur T

    2016-01-01

    We use high-speed video imaging to investigate vapor explosions during the impact of a molten Field's metal drop onto a pool of water. These explosions occur for temperatures above the Leidenfrost temperature and are observed to occur in up to three stages as the metal temperature is increased, with each explosion being more powerful that the preceding one. The Field's metal drop breaks up into numerous microbeads with an exponential size distribution, in contrast to tin droplets where the vapor explosion deforms the metal to form porous solid structures. We compare the characteristic bead size to the wavelength of the fastest growing mode of the Rayleigh-Taylor instability.

  14. Studies on micro-structures at vapor-liquid interfaces of film boiling on hot liquid surface at arriving of a shock pressure

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Akira; Lee, S. [Tokyo Inst. of Tech. (Japan)

    1998-01-01

    In vapor explosions, a pressure wave (shock wave) plays a fundamental role in the generation, propagation and escalation of the explosion. Transient volume change by rapid heat flow from a high temperature liquid to a low temperature volatile one and phase change generate micro-scale flow and the pressure wave. One of key issues for the vapor explosion is to make clear the mechanism to support the explosive energy release from hot drop to cold liquid. According to our observations by an Image Converter Camera, growth rate of vapor film around a hot tin drop became several times higher than that around a hot Platinum tube at the same conditions when a pressure pulse collapsed the film. The thermally induced fragmentation was followed by the explosive growth rate of the hot drop. In the previous report, we have proposed that the interface instability and fragmentation model in which the fine Taylor instability of vapor-liquid interface at the collapsing and re-growth phase of vapor film and the instability induced by the high pressure spots at the drop surface were assumed. In this study, the behavior of the vapor-liquid interface region at arrival of a pressure pulse was investigated by the CIPRIS code which is able to simulate dynamics of transient multi-phase interface regions. It is compared with the observation results. Through detailed investigations of these results, the mechanisms of the thermal fragmentation of single drop are discussed. (J.P.N.)

  15. Distribution of hanging garden vegetation associations on the Colorado Plateau, USA

    Science.gov (United States)

    James F. Fowler; N. L. Stanton; Ronald L. Hartman

    2007-01-01

    Hanging gardens are island-like habitats dominated by mesophytic-hydrophytic plant communities, growing on seeps on the xeric canyon walls of the Colorado Plateau in the American West. We measured the abundance of species and physical microhabitat characteristics of 73 individual hanging gardens during the growing seasons of 1991-1993. Cluster analysis of a simplified...

  16. Experimental investigation and correlation of two-phase frictional pressure drop of R410A-oil mixture flow boiling in a 5 mm microfin tube

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Guoliang; Hu, Haitao; Huang, Xiangchao [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, Shanghai 200240 (China); Deng, Bin [Institute of Heat Transfer Technology, Golden Dragon Precise Copper Tube Group Inc., Shanghai 200135 (China); Gao, Yifeng [International Copper Association, Shanghai Office, Shanghai 200020 (China)

    2009-01-15

    This study presents experimental two-phase frictional data for R410A-oil mixture flow boiling in an internal spiral grooved microfin tube with outside diameter of 5 mm. Experimental parameters include the evaporation temperature of 5 C, the mass flux from 200 to 400 kg m{sup -2} s{sup -1}, the heat flux from 7.46 to 14.92 kW m{sup -2}, the inlet vapor quality from 0.1 to 0.8, and nominal oil concentration from 0 to 5%. The test results show that the frictional pressure drop of R410A initially increases with vapor quality and then decreases, presenting a local maximum in the vapor quality range between 0.7 and 0.8; the frictional pressure drop of R410A-oil mixture increases with the mass flux, the presence of oil enhances two-phase frictional pressure drop, and the effect of oil on frictional pressure drop is more evident at higher vapor qualities where the local oil concentrations are higher. The enhanced factor is always larger than unity and increases with nominal oil concentration at a given vapor quality. The range of the enhanced factor is about 1.0-2.2 at present test conditions. A new correlation to predict the local frictional pressure drop of R410A-oil mixture flow boiling inside the internal spiral grooved microfin tube is developed based on local properties of refrigerant-oil mixture, and the measured local frictional pressure drop is well correlated with the empirical equation proposed by the authors. (author)

  17. Theoretical investigations on the fragmentation of drops of melt with respect to the description of thermal detonations (vapor explosions) and their application in the code Frademo

    International Nuclear Information System (INIS)

    Burger, M.; Carachalios, C.; Kim, D.S.; Unger, H.

    1986-01-01

    Vapor explosions caused by the contact of molten core material with coolant are an important issue within reactor safety analysis, because they could produce an early threat to the containment during a core melt accident. The case of steady-state propagation of a detonation wave through a coarse premixture of melt and coolant represents the most severe case of a large scale vapor explosion under reactor conditions with the highest rate and largest heat release and therefore also the highest yield of mechanical energy. The present contribution starts with the description of the integral model of the detonation wave. The fragmentation processes, which are decisive for these exchange terms and the detonation process as a whole, are dealt with also. Hydrodynamic fragmentation processes as well as a thermally induced one are considered. The processes which take place inside a detonation wave, especially the fragmentation of the drops of melt and the velocity equilibration between the melt and the coolant, determine the behavior of the wave. In the present model these processes are described within a three-phase approach, considering the drops of melt, the fragments and the coolant as separate flow phases. In the frame of this work, the computer code FRADEMO has been developed. It consists of an overall description of the processes inside a steady-state detonation wave in combination with a full description of the detailed models on hydrodynamic and thermal fragmentation presented in this report. Some useful information for the potential code user is given in the appendix of the detailed report also

  18. DSMC simulations of vapor transport toward development of the lithium vapor box divertor concept

    Science.gov (United States)

    Jagoe, Christopher; Schwartz, Jacob; Goldston, Robert

    2016-10-01

    The lithium vapor divertor box concept attempts to achieve volumetric dissipation of the high heat efflux from a fusion power system. The vapor extracts the heat of the incoming plasma by ionization and radiation, while remaining localized in the vapor box due to differential pumping based on rapid condensation. Preliminary calculations with lithium vapor at densities appropriate for an NSTX-U-scale machine give Knudsen numbers between 0.01 and 1, outside both the range of continuum fluid dynamics and of collisionless Monte Carlo. The direct-simulation Monte Carlo (DSMC) method, however, can simulate rarefied gas flows in this regime. Using the solver contained in the OpenFOAM package, pressure-driven flows of water vapor will be analyzed. The use of water vapor in the relevant range of Knudsen number allows for a flexible similarity experiment to verify the reliability of the code before moving to tests with lithium. The simulation geometry consists of chains of boxes on a temperature gradient, connected by slots with widths that are a representative fraction of the dimensions of the box. We expect choked flow, sonic shocks, and order-of-magnitude pressure and density drops from box to box, but this expectation will be tested in the simulation and then experiment. This work is supported by the Princeton Environmental Institute.

  19. Transformation of atmospheric components near a spark discharge at the anode polarization of a metallic electrode hanging over a solution

    Science.gov (United States)

    Orlov, A. M.; Yavtushenko, I. O.; Bodnarskii, D. S.

    2013-03-01

    The variation of the pressure of a gas phase activated by spark discharges between an aqueous electrolyte solution (liquid cathode) and a metallic electrode (anode) hanging over the solution is studied. A mathematical model of the proceeding reaction kinetics is constructed, and the variation of the partial pressures of all initial and produced components in the gas phase is calculated. Both the Faraday and non-Faraday mechanisms of gas component production from water are confirmed. It is found that a large overhanging drop responsible for additional supply of simultaneously produced H2 and O2 molecules forms rapidly at the end face of the anodically polarized electrode.

  20. Kritik Mitos Tentang “Hang Tuah” Karya Amir Hamzah

    OpenAIRE

    Santosa, Puji

    2014-01-01

    This study reveals the myth criticism on rhyme "Hang Tuah", an Amir Hamzah’s work expressing Malay myth. The Malay myth found in the rhyme "Hang Tuah" is placed as a meeting place of myth criticism study which includes (1) the structure of the text, (2) figure with its ideology, (3) setting presenting the myth, (4) type of myth, (5) method the poet displays the myth, and (6) the benefit or function of myth. The six elements of the review are expected to contribute in exposing and describing t...

  1. Hanging out with Which Friends? Friendship-Level Predictors of Unstructured and Unsupervised Socializing in Adolescence

    Science.gov (United States)

    Siennick, Sonja E.; Osgood, D. Wayne

    2012-01-01

    Companions are central to explanations of the risky nature of unstructured and unsupervised socializing, yet we know little about whom adolescents are with when hanging out. We examine predictors of how often friendship dyads hang out via multilevel analyses of longitudinal friendship-level data on over 5,000 middle schoolers. Adolescents hang out…

  2. A case of the CT scanning of a suicidal hanging brain

    International Nuclear Information System (INIS)

    Kawamata, Masaharu; Murooka, Hiroshi; Tanabe, Yasuhiko.

    1988-01-01

    A CT scanning of a case of hanging brain is reported. A 63-year-old man, who had been maintained with Aspirin (30 mg every morning) for cerebral infarction, attempted suicide by hanging, but failed. Several hours later, he was admitted because of consciousness disturbance and so was examined by means of CT scanning. Plain CT scanning showed symmetrical multiple intracerebral hemorrhages. Hemorrhages were found in the subcortical region of the bilateral temporal lobes and in the subependymal region near the foramen of Monro or in the choroidal plexus. We speculated that these hemorrhages may be caused by the congestion of the intracranial venous system caused by squeezing both internal jugular veins by hanging. Past angiograms (1981) for cerebral infarction revealed neither AVM nor angioma. (author)

  3. Universal method for opnimal design main structural assemblies of steel structures stationary conveyor with hanging ribbon

    Directory of Open Access Journals (Sweden)

    Boslovyak P.V.

    2015-10-01

    Full Text Available The technique and the detailed algorithm for optimal design of steel structures hospitaltion of the conveyor with hang-ing ribbon. Developed a universal objective function together with the system-limited-subject to limits of main components of steel structures of stationary conveyor with hanging ribbon.

  4. Crystallization and preliminary X-ray crystallographic analysis of the ArsM arsenic(III) S-adenosylmethionine methyltransferase

    International Nuclear Information System (INIS)

    Marapakala, Kavitha; Ajees, A. Abdul; Qin, Jie; Sankaran, Banumathi; Rosen, Barry P.

    2010-01-01

    A common biotransformation of arsenic is methylation to monomethylated, dimethylated and trimethylated species, which is catalyzed by the ArsM (or AS3MT) arsenic(III) S-adenosylmethionine methyltransferase. ArsM from the acidothermophilic alga Cyanidioschyzon sp. 5508 was expressed, purified and crystallized by the hanging-drop vapor-diffusion method and diffraction data were collected to 1.76 Å resolution. Arsenic is the most ubiquitous environmental toxin and carcinogen and consequently ranks first on the Environmental Protection Agency’s Superfund Priority List of Hazardous Substances. It is introduced primarily from geochemical sources and is acted on biologically, creating an arsenic biogeocycle. A common biotransformation is methylation to monomethylated, dimethylated and trimethylated species. Methylation is catalyzed by the ArsM (or AS3MT) arsenic(III) S-adenosylmethionine methyltransferase, an enzyme (EC 2.1.1.137) that is found in members of every kingdom from bacteria to humans. ArsM from the thermophilic alga Cyanidioschyzon sp. 5508 was expressed, purified and crystallized. Crystals were obtained by the hanging-drop vapor-diffusion method. The crystals belonged to the monoclinic space group C2, with unit-cell parameters a = 84.85, b = 46.89, c = 100.35 Å, β = 114.25° and one molecule in the asymmetric unit. Diffraction data were collected at the Advanced Light Source and were processed to a resolution of 1.76 Å

  5. HangOut: generating clean PSI-BLAST profiles for domains with long insertions.

    Science.gov (United States)

    Kim, Bong-Hyun; Cong, Qian; Grishin, Nick V

    2010-06-15

    Profile-based similarity search is an essential step in structure-function studies of proteins. However, inclusion of non-homologous sequence segments into a profile causes its corruption and results in false positives. Profile corruption is common in multidomain proteins, and single domains with long insertions are a significant source of errors. We developed a procedure (HangOut) that, for a single domain with specified insertion position, cleans erroneously extended PSI-BLAST alignments to generate better profiles. HangOut is implemented in Python 2.3 and runs on all Unix-compatible platforms. The source code is available under the GNU GPL license at http://prodata.swmed.edu/HangOut/. Supplementary data are available at Bioinformatics online.

  6. SUITABILITY OF CORNEAL TISSUE FOR TRANSPLANTATION PROCURED FROM HANGING CASES

    Directory of Open Access Journals (Sweden)

    Rekha Gyanchand

    2017-06-01

    Full Text Available BACKGROUND Requirement of donor cornea is essential to target the corneal blind. The best method to procure such corneas is from any major hospitals, which has a mortuary facility. The eye donation with hanging as the cause of death is very common in a mortuary setup. Some factors that are concerning regarding corneas procured from death due to hanging is the prolonged exposure of the cornea at the time of death, the exact time of death is not known, most of the cadavers are refrigerated for investigations as these arrive at the mortuary usually at night. Due to these reasons, the corneal surgeons are hesitant to use corneas procured from death due to hanging for corneal transplantation. Analysing these corneas would contribute to a great extent to the donor cornea pool in providing sight to the corneal blind, especially as majority are young individuals who commit suicide by hanging. In this study, the donor corneas were analysed with regards to corneal epithelial defect, endothelial cell morphology and utilisation of these corneas for transplantation. The aim of the HCRP study is to analyse the effect of death due to hanging on donor cornea. 1. Corneal epithelial status. 2. Corneal endothelial cell morphology. 3. Utilisation of corneas for transplantation. MATERIALS AND METHODS Donor corneas from 22 donors who died due to hanging were procured from hospital mortuary. All the 44 corneas were transplanted. Various parameters like demography, death to enucleation time, cadaver preservation in cold storage, endothelial cell density and utilisation of cornea for transplantation were noted. Design- Retrospective study. Statistical Analysis- Descriptive statistics, Pearson and Spearman correlation and Chi-square test were used to test the hypotheses. RESULTS Out of the 44 corneas analysed, 75% of the donors were refrigerated as a part of medicolegal investigations protocol. The average DTP time was 12 hours in refrigerated group and 5 hours in non

  7. Experimental study of the thermal interaction for molten tin dropped into water

    International Nuclear Information System (INIS)

    Arakeri, V.H.; Catton, I.; Kastenberg, W.E.; Plesset, M.S.

    1975-12-01

    Multiflash photography with extremely short exposure duration times has been used to observe the interaction of molten tin dropped into a water bath. Detailed photographic evidence is presented which demonstrates that transition, or nucleate boiling, is a possible triggering mechanism for vapor explosions and fragmentation. It was also found that the thermal constraints required to produce vapor explosions could be relaxed by introducing a stable thermal stratification within the coolant. It is shown that the constraints can be relaxed sufficiently to cause vapor explosions for test conditions for which the calculated interface contact temperatures are lower than the homogeneous nucleation temperature of water. This latter finding shows that achievement of limiting coolant superheats associated with spontaneous nucleation is not the only mechanism by which vapor explosions in liquid-liquid systems are possible

  8. Sistem Informasi Akademik pada SMA Hang Tuah Belawan

    OpenAIRE

    Tanjung, Dini Syahroni

    2015-01-01

    Informasi yang disampaikan oleh SMA HANG TUAH BELAWAN selama ini disebarkan melalui brosur dan cara yang seperti itu kurang efektif. Oleh karena itu dibuatlah sistem informasi akademik ini agar penyampaian informasinya lebih efektif dan efisien. 092406181

  9. Optimum design of vaporizer fin with liquefied natural gas by numerical analysis

    International Nuclear Information System (INIS)

    Jeong, Hyo Min; Chung, Han Shik; Lee, Sang Chul; Kong, Tae Woo; Yi, Chung Seub

    2006-01-01

    Generally, the temperature drop under 0 .deg. C on vaporizer surface creates frozen dews. This problem seems to increase as the time progress and humidity rises. In addition, the frozen dews create frost deposition. Consequently, heat transfer on vaporizer decreases because frost deposition causes adiabatic condition. Therefore, it is very important to solve this problem. This paper aims to study of the optimum design of used vaporizer at local LNG station. In this paper, experimental results were compared with numerical results. Geometries of numerical and experimental vaporizers were identical. Studied parameters of vaporizer are angle between two fins (Φ) and fin thickness (TH F ). Numerical analysis results were presented through the correlations between the ice layer thickness (TH ICE ) on the vaporizer surface to the temperature distribution of inside vaporizer (T IN ), fin thickness (TH F ), and angle between two fins (Φ). Numerical result shows good agreement with experimental outcome. Finally, the correlations for optimum design of vaporizer are proposed on this paper

  10. Effect of degree of subcooling on vapor explosion

    International Nuclear Information System (INIS)

    Xu Zhihong; Yang Yanhua; Li Tianshu

    2010-01-01

    In order to investigate the mechanism of the vapor explosion, an observable experiment equipment for low-temperature molten materials to be dropped into water was designed. In the experiment, molten material jet was injected into water to experimentally obtain the visualized information. This experiment results show that the degree of subcooling restrains the explosion. In order to validate the result by other aspects, the breakup experiment was conducted. Results show that the degree of water subcooling is important to melt breakup. High temperature of water is easy to increase the vapor generation during molten material falling, which decrease the drag and accelerated the molten material falling. At the same time, more vapor appear around the molten metal decrease the heat transfer amount between water and molten materials. The two experimental results coincide. (authors)

  11. Expression, purification, crystallization and preliminary X-ray analysis of Aeromonas hydrophilia metallo-[beta]-lactamase

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, N.; Toney, J.H.; Fitzgerald, P.M.D. (Merck)

    2010-07-20

    The CphA metallo-{beta}-lactamase from Aeromonas hydrophilia has been expressed, purified and crystallized by the hanging-drop vapor-diffusion method using ammonium sulfate as the precipitant. The crystals exhibit orthorhombic symmetry (P2{sub 1}2{sub 1}2), with unit-cell parameters a = 40.75, b = 42.05, c = 128.88 {angstrom}. There is one monomer in the asymmetric unit and the solvent content is estimated to be 44% by volume. A data set extending to 1.8 {angstrom} has been measured.

  12. Pressure drop in two-phase He I natural circulation loop at low vapour quality

    International Nuclear Information System (INIS)

    Baudouy, B.

    2003-01-01

    Steady state pressure drop in a two-phase He I natural circulation loop has been measured at atmospheric pressure. Results are obtained up to 0.2 exit vapor quality for a 14-mm diameter copper tube heated over a length of 1.2 m. Pressure drop assessment, done with the momentum balance equation including subcooling, reveals that the homogeneous model and Friedel's friction multiplier associated with Huq and Loth's void fraction correlations predict data within 15%. (author)

  13. A Local Propagation for Vapor Explosions

    International Nuclear Information System (INIS)

    Ochiai, M.; Bankoff, S.G.

    1976-01-01

    Explosive boiling, defined as energy transfer leading to formation of vapor rapidly enough to produce large shock waves, has been widely studied in a number of contexts. Depending upon the nature and temperatures of the liquids and mode of contacting, large-scale mixing and explosive vaporization may occur, or alternatively, only relatively non-energetic, film-type boiling may exist. The key difference is whether a mechanism is operative for increasing the liquid-liquid interfacial area in a time scale consistent with the formation of a detonation wave. Small drops of a cold volatile liquid were dropped onto a free surface of a hot, non-volatile liquid. The critical Weber number for coalescence is obtained from the envelope of the film boiling region. Markedly different behavior for the two hot liquids is observed. A 'splash' theory for local propagation of vapor explosions in spontaneously nucleating liquid-liquid systems is now formulated. After a random contact is made, explosive growth and coalescence of the vapor bubbles occurs as soon as the surrounding pressure is relieved, resulting in a high-pressure vapor layer at the liquid-liquid contact area. This amounts to an impact pressure applied to the free surface, with a resulting velocity distribution obtained from potential flow theory. The peak pressure predictions are. consistent with data for Freon-oil mixing, but further evaluation will await additional experimental data. Nevertheless, the current inference is that a UO 2 -Na vapor explosion in a reactor environment cannot be visualized. In conclusion: The propagation model presented here differs in some details from that of Henry and Fauske, although both are consistent with some peak pressure data obtained by Henry, et al. Clearly, additional experimental information is needed for further evaluation of these theories. Nevertheless, it should be emphasized that even at this time a number of important observations concerning the requirements for a vapor

  14. Wireless Orbiter Hang-Angle Inclinometer System

    Science.gov (United States)

    Lucena, Angel; Perotti, Jose; Green, Eric; Byon, Jonathan; Burns, Bradley; Mata, Carlos; Randazzo, John; Blalock, Norman

    2011-01-01

    A document describes a system to reliably gather the hang-angle inclination of the orbiter. The system comprises a wireless handheld master station (which contains the main station software) and a wireless remote station (which contains the inclinometer sensors, the RF transceivers, and the remote station software). The remote station is designed to provide redundancy to the system. It includes two RF transceivers, two power-management boards, and four inclinometer sensors.

  15. Simulation of hanging dams downstream of Ossauskoski power plant

    Energy Technology Data Exchange (ETDEWEB)

    Aaltonen, J.; Huokuna, M. [Finnish Environment Inst., Helsinki (Finland); Severinkangas, K.; Talvensaari, M. [Kemijoki Oy, Rovaniemi (Finland)

    2008-07-01

    Sixteen power plants have been constructed along Finland's Kemijoki River for hydroelectric power production. The Ossauskoski facility has recently undergone major renovations and upgrade, making it the sixth largest hydroelectric power plant in Finland, with a new capacity of 124 MW and an annual energy output of 501 GWh. The increase in power output and discharge may cause changes in ice conditions downstream of the power plant. The section of the river is already subjected to frazil ice problems and hanging dam formation. Discharges and adverse effects of frazil ice phenomena are likely to increase due to climate change, resulting in harm for hydropower production and the environment, particularly in flow regulated rivers where winter discharges are higher than natural discharges. As such, a study was launched to investigate a dredge plan suggested by by the electric utility Kemijoki Oy. The project involved mapping the river bed topography to identify the location and extent of hanging dams. A sounding device and ground penetrating radar was used to find the thaw regions in the ice cover. The JJT numerical river ice model was effectively used to study the effect of hanging dams on water levels. However, the ice bridging phenomena was not modelled in a reliable way by the JJT model and will be modelled in the future using the CRISSP2D numerical model. 5 refs., 11 figs.

  16. Pressure drop in two-phase He I natural circulation loop at low vapour quality

    Energy Technology Data Exchange (ETDEWEB)

    Baudouy, B

    2003-01-01

    Steady state pressure drop in a two-phase He I natural circulation loop has been measured at atmospheric pressure. Results are obtained up to 0.2 exit vapor quality for a 14-mm diameter copper tube heated over a length of 1.2 m. Pressure drop assessment, done with the momentum balance equation including subcooling, reveals that the homogeneous model and Friedel's friction multiplier associated with Huq and Loth's void fraction correlations predict data within 15%. (author)

  17. Experimental and analytical study of two-phase pressure drops during evaporation in horizontal tubes

    OpenAIRE

    Moreno Quibén, Jesús; Thome, John Richard

    2007-01-01

    Two-phase flow of gases and liquids or vapors and liquids in pipes, channels, equipment, etc. is frequently encountered in industry and has been studied intensively for many years. The reliable prediction of pressure drop in two-phase flow is thereby an important aim. Because of the complexity of these types of flow, empirical or semiempirical relationships are only of limited reliability and pressure drops predicted using leading methods may differ by up to 100%. In order to improve predicti...

  18. Thermal-hydraulic behaviors of vapor-liquid interface due to arrival of a pressure wave

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, Akira; Fujii, Yoshifumi; Matsuzaki, Mitsuo [Tokyo Institute of Technology (Japan)

    1995-09-01

    In the vapor explosion, a pressure wave (shock wave) plays a fundamental role for triggering, propagation and enhancement of the explosion. Energy of the explosion is related to the magnitude of heat transfer rate from hot liquid to cold volatile one. This is related to an increasing rate of interface area and to an amount of transient heat flux between the liquids. In this study, the characteristics of transient heat transfer and behaviors of vapor film both on the platinum tube and on the hot melt tin drop, under same boundary conditions have been investigated. It is considered that there exists a fundamental mechanism of the explosion in the initial expansion process of the hot liquid drop immediately after arrival of pressure wave. The growth rate of the vapor film is much faster on the hot liquid than that on the solid surface. Two kinds of roughness were observed, one due to the Taylor instability, by rapid growth of the explosion bubble, and another, nucleation sites were observed at the vapor-liquid interface. Based on detailed observation of early stage interface behaviors after arrival of a pressure wave, the thermal fragmentation mechanism is proposed.

  19. Etiology and Use of the “Hanging Drop” Technique: A Review

    Science.gov (United States)

    Todorov, Ludmil; VadeBoncouer, Timothy

    2014-01-01

    Background. The hanging drop (HD) technique presumably relies on the presence of subatmospheric epidural pressure. It is not clear whether this negative pressure is intrinsic or an artifact and how it is affected by body position. There are few data to indicate how often HD is currently being used. Methods. We identified studies that measured subatmospheric pressures and looked at the effect of the sitting position. We also looked at the technique used for cervical and thoracic epidural anesthesia in the last 10 years. Results. Intrinsic subatmospheric pressures were measured in the thoracic and cervical spine. Three trials studied the effect of body position, indicating a higher incidence of subatmospheric pressures when sitting. The results show lower epidural pressure (−10.7 mmHg) with the sitting position. 28.8% of trials of cervical and thoracic epidural anesthesia that documented the technique used, utilized the HD technique. When adjusting for possible bias, the rate of HD use can be as low as 11.7%. Conclusions. Intrinsic negative pressure might be present in the cervical and thoracic epidural space. This effect is more pronounced when sitting. This position might be preferable when using HD. Future studies are needed to compare it with the loss of resistance technique. PMID:24839558

  20. Etiology and Use of the “Hanging Drop” Technique: A Review

    Directory of Open Access Journals (Sweden)

    Ludmil Todorov

    2014-01-01

    Full Text Available Background. The hanging drop (HD technique presumably relies on the presence of subatmospheric epidural pressure. It is not clear whether this negative pressure is intrinsic or an artifact and how it is affected by body position. There are few data to indicate how often HD is currently being used. Methods. We identified studies that measured subatmospheric pressures and looked at the effect of the sitting position. We also looked at the technique used for cervical and thoracic epidural anesthesia in the last 10 years. Results. Intrinsic subatmospheric pressures were measured in the thoracic and cervical spine. Three trials studied the effect of body position, indicating a higher incidence of subatmospheric pressures when sitting. The results show lower epidural pressure (−10.7 mmHg with the sitting position. 28.8% of trials of cervical and thoracic epidural anesthesia that documented the technique used, utilized the HD technique. When adjusting for possible bias, the rate of HD use can be as low as 11.7%. Conclusions. Intrinsic negative pressure might be present in the cervical and thoracic epidural space. This effect is more pronounced when sitting. This position might be preferable when using HD. Future studies are needed to compare it with the loss of resistance technique.

  1. VAPOR MIXER FOR GELATINIZATION OF STARCH IN LIQUEFYING STATION

    Directory of Open Access Journals (Sweden)

    V. V. Ananskikh

    2015-01-01

    Full Text Available Starch hydrolysis is main technological process in production of starch sweeteners. Acid hydrolysis of starch using hydrochloric acid is carried out very fast but it does not allow to carry out full hydrolysis and to produce products with given carbohydrate composition. Bioconversion of starch allows to eliminate these limitations. At production of starch sweeteners from starch using enzymes starch hydrolysis is carried out in two stages At first starch – starch liquefaction the rapid increase of viscosity takes place which requires intensive mixing. Liquefying station consists of jet-cooker, holder, pressure regulator and evaporator. Jet-cooker of starch is its main part, starch is quickly turns into soluble (gelatinized state and it is partially liquefied by injection of starch suspension by flow of water vapor under pressure not less than 0,8 MPa. Heat and hydraulic calculation were carried out in order to determine constructive sizes of mixer for cooking of starch. The main hydraulic definable parameters are pressure drop in mixer, vapor pressure at mixer inlet, daily capacity of station by glucose syrup M, product consumption (starch suspension, diameter of inlet section of vapor nozzle. The goal of calculation was to determine vapor consumption M1, diameter d2 of outlet section of confuser injector, length l2 of gelatinization section. For heat calculation there was used Shukhov’s formula along with heat balance equation for gelatinization process. The numerical solution obtained with adopted assumptions given in applied mathematical package MATHCAD, for M = 50 t/day gives required daily vapor consumption M1 = 14,446 т. At hydraulic calculation of pressure drop in mixer there was used Bernoulli’s theorem. Solving obtained equations using MATHCAD found diameter of outlet section of consufer d2 = 0,023 м, vapor pressure inside of mixer p2 = 3,966·105 Па, l2 = 0,128 м. Developed method of calculation is used to determine

  2. Implementasi Kebijakan Kawasan Tanpa Rokok (KTR) pada Mahasiswa di Lingkungan Sekolah Tinggi Ilmu Kesehatan Hang Tuah Pekanbaru

    OpenAIRE

    Reno Renaldi

    2014-01-01

    Sekolah Tinggi Ilmu Kesehatan (STIKes) Hang Tuah Pekanbaru sebagai tempat pelaksanaan proses belajar mengajar bagi mahasiswa sekaligus tempat kerja bagi karyawannya,  yang mana seyogyanya tempat tersebut menjadi tempat Kawasan Tanpa Rokok berdasarkan Undang-undang kesehatan.Oleh karena itu sejak tahun2011STIKes Hang Tuah telah mengeluarkan kebijakan dalam bentuk surat edaran dengan nomor surat No/09/STIKes-HTP/IX/2011/289/mengenai Kawasan Tanpa Rokok di lingkungan STIKes Hang Tuah Pekanbaru.P...

  3. Death by hanging: implications for prevention of an important method of youth suicide.

    Science.gov (United States)

    Kosky, R J; Dundas, P

    2000-10-01

    The aim of this study was to identify factors associated with deaths by hanging among young people in Queensland, Australia. An examination of coroner's reports for all deaths by hanging of people under 25 years of age that occurred in Queensland in the years 1995 and 1996. All cases were recorded as suicides. Most were males and a quarter were indigenous persons. Half the deaths occurred in regional or rural areas. Unemployment, the experience of personal loss, psychiatric illness and alcohol use were possible precipitating agents. Early warning signs were the onset of uncharacteristic behaviours and threats of suicide. The private nature of hanging means that there are rarely opportunities to prevent it in the period immediately before the fatal event. Earlier interventions will have to be considered. To prevent hanging as a means of suicide, we need to understand more about the difficulties experienced by some young men who are living in rural areas. We need more information about the cultural problems experienced by indigenous youths in their teenage years. Young people in the justice system may need personal support. There is a pressing need to determine if young people, especially in rural areas, have adequate access to the professional expertise needed to diagnose and treat mental disorders.

  4. CASE REPORT OF SUCCESSFUL RESUSCITATION OF A CASE O F SUICIDAL HANGING

    OpenAIRE

    Yanki D.

    2013-01-01

    ABSTRACT: In Sikkim, the rate of suicide has been on the rise since the last 10 years. Suicidal hanging as method of ending life is a major concern among school children. It is very rare that the victims are brought on time for successful resuscit ation in Sikkim. Suicide by hanging is probably the most easy way to go about taking one’s own life , as the means to do it are easily available and uncomplicated and, brutally efficient in most case s . This is a case ...

  5. Two-phase pressure drop and flow visualization of FC-72 in a silicon microchannel heat sink

    International Nuclear Information System (INIS)

    Megahed, Ayman; Hassan, Ibrahim

    2009-01-01

    The rapid development of two-phase microfluidic devices has triggered the demand for a detailed understanding of the flow characteristics inside microchannel heat sinks to advance the cooling process of micro-electronics. The present study focuses on the experimental investigation of pressure drop characteristics and flow visualization of a two-phase flow in a silicon microchannel heat sink. The microchannel heat sink consists of a rectangular silicon chip in which 45 rectangular microchannels were chemically etched with a depth of 276 μm, width of 225 μm, and a length of 16 mm. Experiments are carried out for mass fluxes ranging from 341 to 531 kg/m 2 s and heat fluxes from 60.4 to 130.6 kW/m 2 using FC-72 as the working fluid. Bubble growth and flow regimes are observed using high speed visualization. Three major flow regimes are identified: bubbly, slug, and annular. The frictional two-phase pressure drop increases with exit quality for a constant mass flux. An assessment of various pressure drop correlations reported in the literature is conducted for validation. A new general correlation is developed to predict the two-phase pressure drop in microchannel heat sinks for five different refrigerants. The experimental pressure drops for laminar-liquid laminar-vapor and laminar-liquid turbulent-vapor flow conditions are predicted by the new correlation with mean absolute errors of 10.4% and 14.5%, respectively.

  6. Anatomical basis of the liver hanging maneuver.

    Science.gov (United States)

    Trotovsek, Blaz; Belghiti, Jacques; Gadzijev, Eldar M; Ravnik, Dean; Hribernik, Marija

    2005-01-01

    The anterior approach to right hepatectomy using the liver hanging maneuver without liver mobilization claims to be anatomically evaluated. During this procedure a 4 to 6-cm blind dissection between the inferior vena cava and the liver is performed. Short subhepatic veins, entering the inferior vena cava could be torn and a hemorrhage, difficult to control, could occur. On 100 corrosive casts of livers the anterior surface of the inferior vena cava was studied to evaluate the position, diameter and draining area of short subhepatic veins and inferior right hepatic vein. The width of the narrowest point on the planned route of blind dissection was determined. The average value of the narrowest point on the planned route of blind dissection was 8.7+/-2.3mm (range 2-15mm). The ideal angle of dissection being 0 degrees was found in 93% of cases. In 7% we found the angle of 5 degrees toward the right border of inferior vena cava to be the better choice. Our results show that liver hanging maneuver is a safe procedure. With the dissection in the proposed route the risk of disrupting short subhepatic veins is low (7%).

  7. Vapor-phase biofiltration: Laboratory and field experience

    International Nuclear Information System (INIS)

    Evans, P.J.; Bourbonais, K.A.; Peterson, L.E.; Lee, J.H.; Laakso, G.L.

    1995-01-01

    Application of vapor-phase bioreactors (VPBs) to petroleum hydrocarbons is complicated by the different mass transfer characteristics of aliphatics and aromatics. Laboratory- and pilot-scale VPB studies were conducted to evaluate treatment of soil vapor extraction (SVE) off-gas. A mixture of compost, perlite, and activated carbon was the selected medium based on pressure drop, microbial colonization, and adsorption properties. Two different pilot-scale reactors were built with a difference of 70:1 in scale. The smaller VPB's maximum effective elimination capacity (EC) was determined to be 7.2 g m -3 h -1 ; the larger unit's EC was 70% to 80% of this value. Low EC values may be attributable to a combination of mass-transfer and kinetic limitations

  8. A novel fabrication technique for free-hanging homogeneous polymeric cantilever waveguides

    International Nuclear Information System (INIS)

    Nordström, Maria; Hübner, Jörg; Boisen, Anja; Calleja, Montserrat

    2008-01-01

    We present a novel bonding technique developed for the fabrication of a cantilever-based biosensing system with integrated optical read-out. The read-out mechanism is based on single-mode waveguides fabricated monolithically in SU-8. For optimal operation of the read-out mode, the cantilever waveguides should be homogenous and this bonding technique ensures free-hanging cantilevers that are surrounded by the same material for bottom and top claddings. The bonding step is necessary because SU-8 is a negative resist where free-hanging structures cannot be fabricated directly. This paper gives details on the processing aspects and the parameters of the fabrication steps

  9. Prediction of pressure drop and CCFL breakdown in countercurrent two-phase flow

    International Nuclear Information System (INIS)

    Ostrogorsky, A.G.; Gay, R.R.; Lahey, R.T. Jr.

    1983-01-01

    A steady-state analytical has been developed to predict channel pressure drop as a function of inlet vapor flow rate and applied heat flux during conditions of countercurrent two-phase flow. The interfacial constitutive relations utilized are flow surface dependent and allow for the existence of either smooth or way liquid films. A computer code was developed to solve the analytical model. Predictions of Δp versus vapor flow rate were found to agree favorably with experimental data from adiabatic, air/water systems. In addition, the model was used to predict countercurrent flow conditions in heated channels characteristic of a BWR/4 nuclear reactor fuel assembly

  10. Perilaku Seks Pranikah pada Mahasiswa STIKes Hang Tuah Pekanbaru

    Directory of Open Access Journals (Sweden)

    Novita Rany

    2012-11-01

    Full Text Available Hasil penelitian PKBI (Persatuan Keluarga Berencana Indonesia – Riau tahun 2009 bahwa 38,75 % pria sudah melakukan hubungan seks pranikah sedangkan wanita 16,98 %. Penelitian ini menggunakan metode kualitatif. Subjek penelitian adalah mahasiswa STIKes Hang Tuah Pekanbaru, informan kunci merupakan dosen bagian kemahasiswaan, orang tua, ibu kos dan teman dekat. Dari penelitian ini diperoleh bahwa Perilaku seksual dibagi kedalam yang tidak berisiko (mulai dari ngobrol dan pegangan tangan saja, dan yang berisiko (dari ciuman sampai dengan berhubungan intim. Dari hasil penelitian diketahui 7 informan yang berisiko dan 9 lainnya tidak berisiko. Hampir separuh (7 dari 16 informan berperilaku seksual yang berisiko dan beberapa diantaranya pernah melakukan hubungan seksual pra nikah. Ada kecenderungan hubungan antara pengetahuan, sikap, persepsi, teman sebaya dan peran keluarga dalam mengawasi pergaulan anaknya terhadap perilaku seks berisiko. Saran bagi STIKes Hang Tuah dan Dinas Kesehatan agar dapat memasukan pendidikan seks kedalam kurikulum

  11. Finite size and Coulomb corrections: from nuclei to nuclear liquid vapor phase diagram

    International Nuclear Information System (INIS)

    Moretto, L.G.; Elliott, J.B.; Phair, L.

    2003-01-01

    In this paper we consider the problem of obtaining the infinite symmetric uncharged nuclear matter phase diagram from a thermal nuclear reaction. In the first part we shall consider the Coulomb interaction which, because of its long range makes the definition of phases problematic. This Coulomb effect seems truly devastating since it does not allow one to define nuclear phase transitions much above A ∼ 30. However there may be a solution to this difficulty. If we consider the emission of particles with a sizable charge, we notice that a large Coulomb barrier Bc is present. For T << Bc these channels may be considered effectively closed. Consequently the unbound channels may not play a role on a suitably short time scale. Then a phase transition may still be definable in an approximate way. In the second part of the article we shall deal with the finite size problem by means of a new method, the complement method, which shall permit a straightforward extrapolation to the infinite system. The complement approach consists of evaluating the change in free energy occurring when a particle or cluster is moved from one (finite) phase to another. In the case of a liquid drop in equilibrium with its vapor, this is done by extracting a vapor particle of any given size from the drop and evaluating the energy and entropy changes associated with both the vapor particle and the residual liquid drop (complement)

  12. Death by hanging while watching violent pornographic videos on the Internet - suicide or accidental autoerotic death?

    Science.gov (United States)

    Vennemann, B; Pollak, S

    2006-03-01

    In deaths by hanging, it may sometimes be difficult to differentiate between autoerotic accident and suicide. Our report deals with a 30-year-old man who was found hanged in the living room of his flat. The deceased was wearing headphones connected to a PC. Within the deceased's view was a computer screen showing the last picture of a video file downloaded from the Internet with the head of an unclothed, allegedly hanged female. The deceased's left hand was inside his trousers in the genital region. The autopsy did not only show findings typical for hanging, but also advanced sarcoidosis, which was known to the victim. Although this basic illness could have been a possible motive for suicide, the circumstances in the presented case pointed more in the direction of an accidental autoerotic death. As far as we know, this is the first description of a death during autoerotic activity in which sexual stimulation was achieved by watching a video file downloaded from the Internet.

  13. Experimental Results For Hydrocarbon Refrigerant Vaporization In Brazed Plate Heat Exchangers at High Pressure

    OpenAIRE

    Desideri, Adriano; Schmidt Ommen, Torben; Wronski, Jorrit; Quoilin, Sylvain; Lemort, Vincent; Haglind, Fredrik

    2016-01-01

    In this contribution, the experimental heat transfer coefficient  and the pressure drop measured during HFC refrigerants vaporization inside small brazed plate heat exchanger (PHE) at typical evaporation temperature for organic Rankine cycle systems for low thermal energy quality applications are presented. Scientific work focusing on the heat transfer in PHEs has been carried out since the late 19th century. More recent publications have been focusing on vaporization and condensation of ref...

  14. Efficient biotechnological approach for lentiviral transduction of induced pluripotent stem cells.

    Science.gov (United States)

    Zare, Mehrak; Soleimani, Masoud; Mohammadian, Mozhdeh; Akbarzadeh, Abolfazl; Havasi, Parvaneh; Zarghami, Nosratollah

    2016-01-01

    Induced pluripotent stem (iPS) cells are generated from differentiated adult somatic cells by reprogramming them. Unlimited self-renewal, and the potential to differentiate into any cell type, make iPS cells very promising candidates for basic and clinical research. Furthermore, iPS cells can be genetically manipulated for use as therapeutic tools. DNA can be introduced into iPS cells, using lentiviral vectors, which represent a helpful choice for efficient transduction and stable integration of transgenes. In this study, we compare two methods of lentiviral transduction of iPS cells, namely, the suspension method and the hanging drop method. In contrast to the conventional suspension method, in the hanging drop method, embryoid body (EB) formation and transduction occur concurrently. The iPS cells were cultured to form EBs, and then transduced with lentiviruses, using the conventional suspension method and the hanging drop method, to express miR-128 and green fluorescent protein (GFP). The number of transduced cells were assessed by fluorescent microscopy and flow cytometry. MTT assay and real-time PCR were performed to determine the cell viability and transgene expression, respectively. Morphologically, GFP+ cells were more detectable in the hanging drop method, and this finding was quantified by flow cytometric analysis. According to the results of the MTT assay, cell viability was considerably higher in the hanging drop method, and real-time PCR represented a higher relative expression of miR-128 in the iPS cells introduced with lentiviruses in drops. Altogether, it seems that lentiviral transduction of challenging iPS cells using the hanging drop method offers a suitable and sufficient strategy in their gene transfer, with less toxicity than the conventional suspension method.

  15. Water resources and effects of potential surface coal mining on dissolved solids in Hanging Woman Creek basin, southeastern Montana

    Science.gov (United States)

    Cannon, M.R.

    1989-01-01

    Groundwater resources of the Hanging Woman Creek basin, Montana include Holocene and Pleistocene alluvial aquifers and sandstone , coal, and clinker aquifers in the Paleocene Fort Union Formation. Surface water resources are composed of Hanging Woman Creek, its tributaries, and small stock ponds. Dissolved-solids concentrations in groundwater ranged from 200 to 11,00 mg/L. Generally, concentrations were largest in alluvial aquifers and smallest in clinker aquifers. Near its mouth, Hanging Woman Creek had a median concentration of about 1,800 mg/L. Mining of the 20-foot to 35-foot-thick Anderson coal bed and 3-foot to 16-foot thick Dietz coal bed could increase dissolved-solids concentrations in shallow aquifers and in Hanging Woman Creek because of leaching of soluble minerals from mine spoils. Analysis of saturated-paste extracts from 158 overburden samples indicated that water moving through mine spoils would have a median increase in dissolved-solids concentration of about 3,700 mg/L, resulting in an additional dissolved-solids load to Hanging Woman Creek of about 3.0 tons/day. Hanging Woman Creek near Birney could have an annual post-mining dissolved-solids load of 3,415 tons at median discharge, a 47% increase from pre-mining conditions load. Post-mining concentrations of dissolved solids, at median discharge, could range from 2,380 mg/L in March to 3,940 mg/L in August, compared to mean pre-mining concentrations that ranged from 1,700 mg/L in July, November, and December to 2,060 mg/L in May. Post-mining concentrations and loads in Hanging Woman Creek would be smaller if a smaller area were mined. (USGS)

  16. Tritiated water vapor in the surface air at Tokyo

    International Nuclear Information System (INIS)

    Inoue, Hisayuki; Katsuragi, Yukio; Shigehara, Koji

    1984-01-01

    Tritium concentration in water vapor in the air near the surface and in the precipitation at Tokyo was measured during the period from 9 August to 20 November in 1974. From August to the middle of October, tritium mixing ratios in the surface air had relatively higher values except those in air masses which were associated with a typhoon. The mixing ratios of tritium in the air decreased abruptly at the middle of October, which indicates the decrease of tritium influx from aloft. These data exhibit the salient feature that variations in tritium concentration in TR are linear to the reciprocal of the content of water vapor during each period. Tritium concentrations in vapor and rain water collected simultaneously show nearly equal values. One of the reasons for the good correlation of tritium concentration between falling drops and ambient air is considered to be the result of the rapid isotopic exchange. (author)

  17. Unusual planned complex suicide committed with a muzzle-loading pistol in combination with subsequent hanging.

    Science.gov (United States)

    Ondruschka, Benjamin; Morgenthal, Sylvia; Dreβler, Jan; Bayer, Ronny

    2016-11-01

    In Germany, suicides by firearms are not very common in contrast to deaths by hanging and intoxications. The use of historical muzzle-loading firearms in the context of suicides is a rarity. Contact shots from muzzle loaders cause an unusual wound morphology with extensive soot soiling. We report the case of a 59-year-old man, who committed a planned complex suicide by shooting into his mouth with a replica percussion gun in combination with hanging. The gunshot injury showed strong explosive effects in the oral cavity with fractures of the facial bones and the skull associated with cerebral evisceration (so-called Krönlein shot). Due to the special constellation of the case with hanging immediately after the shot, external bleeding from the head injuries was only moderate. Therefore, the head injuries could be assessed and partially reconstructed already at the scene.

  18. A tree branch instead of a ligature: an unusual accidental hanging.

    Science.gov (United States)

    Vadysinghe, Amal Nishantha; Sivasubramanium, Murugupillai; Jayasooriya, Rankothge Pemasiri

    2017-12-01

    A unique case of accidental hanging due to compression of the neck of an adult by the branches of a coffee tree is reported. The decedent was a 42-year-old male who was found dead in a semi prone position on a slope. His neck was lodged in a wedge formed by two branches of a coffee tree, with his legs angled downwards on the slope. Autopsy revealed two friction abrasions located horizontally on either side of the front of the neck, just above the larynx. The findings were compatible with compression of the neck by the branches of the tree, with the body weight of the decedent contributing to compression. Subsequent complete autopsy examination confirmed the cause of death as hanging. Following an inquest the death was ruled to be accidental.

  19. Reconditioning perovskite films in vapor environments through repeated cation doping

    Science.gov (United States)

    Boonthum, Chirapa; Pinsuwan, Kusuma; Ponchai, Jitprabhat; Srikhirin, Toemsak; Kanjanaboos, Pongsakorn

    2018-06-01

    Perovskites have attracted considerable attention for application as high-efficiency photovoltaic devices owing to their low-cost and low-temperature fabrication. A good surface and high crystallinity are necessary for high-performance devices. We examine the negative effects of chemical ambiences on the perovskite crystal formation and morphology. The repeated cation doping (RCD) technique was developed to remedy these issues by gradually dropping methylammonium ions on top of about-to-form perovskite surfaces to cause recrystallization. RCD promotes pinhole-free, compact, and polygonal-like surfaces under various vapor conditions. Furthermore, it enhances the electronic properties and crystallization. The benefits of RCD extend beyond perovskites under vapor ambiences, as it can improve regular and wasted perovskites.

  20. Approach for growth of high-quality and large protein crystals

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Hiroyoshi, E-mail: matsumura@chem.eng.osaka-u.ac.jp [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); JST (Japan); SOSHO Inc., Osaka 541-0053 (Japan); Sugiyama, Shigeru; Hirose, Mika; Kakinouchi, Keisuke; Maruyama, Mihoko; Murai, Ryota [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); JST (Japan); Adachi, Hiroaki; Takano, Kazufumi [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); JST (Japan); SOSHO Inc., Osaka 541-0053 (Japan); Murakami, Satoshi [JST (Japan); SOSHO Inc., Osaka 541-0053 (Japan); Graduate School of Bioscience and Biotechnology, Tokyo Institute of Technology, Nagatsuta, Midori-ku, Yokohama 226-8501 (Japan); Mori, Yusuke; Inoue, Tsuyoshi [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 (Japan); JST (Japan); SOSHO Inc., Osaka 541-0053 (Japan)

    2011-01-01

    Three crystallization methods, including crystallization in the presence of a semi-solid agarose gel, top-seeded solution growth (TSSG) and a large-scale hanging-drop method, have previously been presented. In this study, crystallization has been further evaluated in the presence of a semi-solid agarose gel by crystallizing additional proteins. A novel crystallization method combining TSSG and the large-scale hanging-drop method has also been developed. Three crystallization methods for growing large high-quality protein crystals, i.e. crystallization in the presence of a semi-solid agarose gel, top-seeded solution growth (TSSG) and a large-scale hanging-drop method, have previously been presented. In this study the effectiveness of crystallization in the presence of a semi-solid agarose gel has been further evaluated by crystallizing additional proteins in the presence of 2.0% (w/v) agarose gel, resulting in complete gelification with high mechanical strength. In TSSG the seed crystals are hung by a seed holder protruding from the top of the growth vessel to prevent polycrystallization. In the large-scale hanging-drop method, a cut pipette tip was used to maintain large-scale droplets consisting of protein–precipitant solution. Here a novel crystallization method that combines TSSG and the large-scale hanging-drop method is reported. A large and single crystal of lysozyme was obtained by this method.

  1. Assessing Quasi-Steady State in Evaporation of Sessile Drops by Diffusion Models

    Science.gov (United States)

    Martin, Cameron; Nguyen, Hoa; Kelly-Zion, Peter; Pursell, Chris

    2017-11-01

    The vapor distributions surrounding sessile drops of methanol are modeled as the solutions of the steady-state and transient diffusion equations using Matlab's PDE Toolbox. The goal is to determine how quickly the transient diffusive transport reaches its quasi-steady state as the droplet geometry is varied between a Weber's disc, a real droplet shape, and a spherical cap with matching thickness or contact angle. We assume that the only transport mechanism at work is diffusion. Quasi-steady state is defined using several metrics, such as differences between the transient and steady-state solutions, and change in the transient solution over time. Knowing the vapor distribution, the gradient is computed to evaluate the diffusive flux. The flux is integrated along the surface of a control volume surrounding the drop to obtain the net rate of diffusion out of the volume. Based on the differences between the transient and steady-state diffusive fluxes at the discrete points along the control-volume surface, the time to reach quasi-steady state evaporation is determined and is consistent with other proposed measurements. By varying the dimensions of the control volume, we can also assess what regimes have equivalent or different quasi-steady states for different droplet geometries. Petroleum Research Fund.

  2. Flat-ramp vs. convex-concave thrust geometries in a deformable hanging wall: new insights from analogue modeling experiments

    Science.gov (United States)

    Almeida, Pedro; Tomas, Ricardo; Rosas, Filipe; Duarte, Joao; Terrinha, Pedro

    2015-04-01

    Different modes of strain accommodation affecting a deformable hanging-wall in a flat-ramp-flat thrust system were previously addressed through several (sandbox) analog modeling studies, focusing on the influence of different variables, such as: a) thrust ramp dip angle and friction (Bonini et al, 2000); b) prescribed thickness of the hanging-wall (Koy and Maillot, 2007); and c) sin-thrust erosion (compensating for topographic thrust edification, e.g. Persson and Sokoutis, 2002). In the present work we reproduce the same experimental procedure to investigate the influence of two different parameters on hanging-wall deformation: 1) the geometry of the thrusting surface; and 2) the absence of a velocity discontinuity (VD) that is always present in previous similar analogue modeling studies. Considering the first variable we use two end member ramp geometries, flat-ramp-flat and convex-concave, to understand the control exerted by the abrupt ramp edges in the hanging-wall stress-strain distribution, comparing the obtain results with the situation in which such edge singularities are absent (convex-concave thrust ramp). Considering the second investigated parameter, our motivation was the recognition that the VD found in the different analogue modeling settings simply does not exist in nature, despite the fact that it has a major influence on strain accommodation in the deformable hanging-wall. We thus eliminate such apparatus artifact from our models and compare the obtained results with the previous ones. Our preliminary results suggest that both investigated variables play a non-negligible role on the structural style characterizing the hanging-wall deformation of convergent tectonic settings were such thrust-ramp systems were recognized. Acknowledgments This work was sponsored by the Fundação para a Ciência e a Tecnologia (FCT) through project MODELINK EXPL/GEO-GEO/0714/2013. Pedro Almeida wants to thank to FCT for the Ph.D. grant (SFRH/BD/52556/2014) under the

  3. Comparative analysis of tumor spheroid generation techniques for differential in vitro drug toxicity

    Science.gov (United States)

    Raghavan, Shreya; Rowley, Katelyn R.; Mehta, Geeta

    2016-01-01

    Multicellular tumor spheroids are powerful in vitro models to perform preclinical chemosensitivity assays. We compare different methodologies to generate tumor spheroids in terms of resultant spheroid morphology, cellular arrangement and chemosensitivity. We used two cancer cell lines (MCF7 and OVCAR8) to generate spheroids using i) hanging drop array plates; ii) liquid overlay on ultra-low attachment plates; iii) liquid overlay on ultra-low attachment plates with rotating mixing (nutator plates). Analysis of spheroid morphometry indicated that cellular compaction was increased in spheroids generated on nutator and hanging drop array plates. Collagen staining also indicated higher compaction and remodeling in tumor spheroids on nutator and hanging drop arrays compared to conventional liquid overlay. Consequently, spheroids generated on nutator or hanging drop plates had increased chemoresistance to cisplatin treatment (20-60% viability) compared to spheroids on ultra low attachment plates (10-20% viability). Lastly, we used a mathematical model to demonstrate minimal changes in oxygen and cisplatin diffusion within experimentally generated spheroids. Our results demonstrate that in vitro methods of tumor spheroid generation result in varied cellular arrangement and chemosensitivity. PMID:26918944

  4. Visualization, granulometry and evaporation of drops and sprays - Study in close and pressurized atmosphere

    International Nuclear Information System (INIS)

    Lassauce, Aurelia

    2011-01-01

    The objective of this thesis is to determine the influence of ambient pressure between 100 and 600 KPa on the evaporation of a drop, and on the evaporation of a spray in the same conditions. The first step is to study the influence of ambient pressure on the evolution of the shape, the diameter, the speed and the evaporation rate of a drop of liquid in free fall. Then, an optical measurement technique has been used and a methodology was developed to calibrate this measurement technique and minimize measurement errors on the particle size. In parallel, an analytical model of evaporation of falling drops has been developed: a particular attention was paid to the determination of an appropriate correlation for the drag coefficient to take into account changes in the shape of drops during their fall. This model of evaporation of drop is compared with a spray evaporation model (taking into account the training of air, the vapor concentration away from the drop and the influence of the pressure to show the limits of this drop evaporation model when applied to the evaporation of a spray. The second phase of the study was to apply the measurement techniques and analysis developed previously to study the drop size of a spray to characterize the influence of three parameters: ambient pressure, injection pressure of the liquid and nature of the liquid. The analysis of the results allowed developing a statistical model to determine the size of the drops of these sprays [fr

  5. Mobile vapor recovery and vapor scavenging unit

    International Nuclear Information System (INIS)

    Stokes, C.A.; Steppe, D.E.

    1991-01-01

    This patent describes a mobile anti- pollution apparatus, for the recovery of hydrocarbon emissions. It comprises a mobile platform upon which is mounted a vapor recovery unit for recovering vapors including light hydrocarbons, the vapor recovery unit having an inlet and an outlet end, the inlet end adapted for coupling to an external source of hydrocarbon vapor emissions to recover a portion of the vapors including light hydrocarbons emitted therefrom, and the outlet end adapted for connection to a means for conveying unrecovered vapors to a vapor scavenging unit, the vapor scavenging unit comprising an internal combustion engine adapted for utilizing light hydrocarbon in the unrecovered vapors exiting from the vapor recovery unit as supplemental fuel

  6. Neurological outcomes following suicidal hanging: A prospective study of 101 patients

    Directory of Open Access Journals (Sweden)

    Mohammed Turab Jawaid

    2017-01-01

    Full Text Available Context: Survivors of suicidal hanging can have variable neurological outcomes – from complete recovery to irreversible brain damage. Literature on the neurological outcomes in these patients is confined to retrospective studies and case series. Hence, this prospective study was carried out. Aims: The aim is to study the neurological outcomes in suicidal hanging. Settings and Design: This was a prospective observational study carried out from July 2014 to July 2016. Subjects and Methods: Consecutive patients admitted to the emergency and medicine wards were included in the study. Details of the clinical and radiological findings, course in hospital and at 1 month postdischarge were analyzed. Statistical Analysis Used: Statistical analysis was performed using IBM SPSS advanced statistics 20.0 (SPSS Inc., Chicago, USA. Univariate analysis was performed using Chi-square test for significance and Odd's ratio was calculated. Results: Of the 101 patients, 6 died and 4 had residual neuro deficits. Cervical spine injury was seen in 3 patients. Interestingly, 39 patients could not remember the act of hanging (retrograde amnesia. Hypotension, pulmonary edema, Glasgow coma scale (GCS score <8 at admission, need for mechanical ventilation, and cerebral edema on plain computed tomography were more in those with amnesia as compared to those with normal memory and these findings were statistically significant. Conclusions: Majority of patients recovered without any sequelae. Routine imaging of cervical spine may not be warranted in all patients, even in those with poor GCS. Retrograde amnesia might be more common than previously believed and further studies are needed to analyze this peculiar feature.

  7. High-throughput method for optimum solubility screening for homogeneity and crystallization of proteins

    Science.gov (United States)

    Kim, Sung-Hou [Moraga, CA; Kim, Rosalind [Moraga, CA; Jancarik, Jamila [Walnut Creek, CA

    2012-01-31

    An optimum solubility screen in which a panel of buffers and many additives are provided in order to obtain the most homogeneous and monodisperse protein condition for protein crystallization. The present methods are useful for proteins that aggregate and cannot be concentrated prior to setting up crystallization screens. A high-throughput method using the hanging-drop method and vapor diffusion equilibrium and a panel of twenty-four buffers is further provided. Using the present methods, 14 poorly behaving proteins have been screened, resulting in 11 of the proteins having highly improved dynamic light scattering results allowing concentration of the proteins, and 9 were crystallized.

  8. Prognosis at 6 and 12months after self-attempted hanging.

    Science.gov (United States)

    Gantois, Guillaume; Parmentier-Decrucq, Erika; Duburcq, Thibault; Favory, Raphaël; Mathieu, Daniel; Poissy, Julien

    2017-11-01

    Patients surviving a self-attempted hanging have a total neurological recovery in 57-77% of cases at hospital discharge, but no long-term data are available. In this observational study, all patients hospitalized post-self-attempted hanging in the intensive care unit (ICU) in a 5-year period were included. Neurological evaluations at 6 and 12months were performed according to Cerebral Performance Category (CPC) scores. Factors associated with neurological recovery were determined by comparing CPC2+3+4 (bad recovery) vs. CPC1 (good recovery). Of 231 patients included, 104 (47%) were found to have cardiac arrest (CA). Ninety-five (41%) patients died in the ICU: 93 (89%) in the CA group and 2 (1.6%) in the group without CA. Neurological evaluations at 6 and 12months were obtained in 97 of the 136 surviving patients. At 6months, in the CA group (n=9), the CPC score was 1 for 6 patients, 2 for 2, and 4 for 1 patient. In the group without CA (n=88), 79 patients had normal neurological status at 6months and 78 at 12months. Among these patients, 96% returned home, 77% returned to work, 16 (18%) patients re-attempted suicide within the year. Risk factors of neurological sequelae at 6months were a CA at the hanging site (P=0.045), an elevated diastolic blood pressure (87 vs. 70 mm Hg; P=0.04), a lower initial Glasgow score (4 vs. 5; P=0.04), and an elevated blood glucose level (139 vs. 113 mg/dL; Pgood neurological outcome. The rate of suicidal recidivism is particularly important, which justifies joint work with psychiatrists. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Flow regime visualization and pressure drops of HFO-1234yf, R-134a and R-410A during downward two-phase flow in vertical return bends

    International Nuclear Information System (INIS)

    Padilla, Miguel; Revellin, Rémi; Wallet, Jérémy; Bonjour, Jocelyn

    2013-01-01

    Highlights: ► Visual observation of two-phase flow regimes during downward flow in a return bend. ► Bubble and vapor slug dynamical behaviors in downward slug flow are reported. ► Perturbation lengths up- and downstream of the return bend have been investigated. ► Measurement of 285 pressure drop data points for HFO-1234yf, R-134a and R-410A. -- Abstract: This paper provides a qualitative visual observation of the two-phase flow patterns for HFO-1234yf and R-134a during downward flow in a vertical 6.7 mm inner diameter glass return bend. The different flow regimes observed are: slug, intermittent and annular flows. Bubble and vapor slug dynamical behaviors in downward slug flow are reported for HFO-1234yf. In addition, to determine the perturbation lengths up- and downstream of the return bend, the total pressure drop has been measured at different pressure tap location up- and downstream of the singularity. Furthermore, 285 pressure drop data points measured for two-phase flow of HFO-1234yf, R-134a and R-410A in vertical downward flow return bends are presented. The flow behavior in the return bend, which is subjected to the complex combined actions of gravity and centrifugal force was expressed in terms of the vapor Froude number. This experimental pressure drop database, which is included in the appendix, is compared to four well-known prediction methods available in the literature

  10. Motion of Drops on Surfaces with Wettability Gradients

    Science.gov (United States)

    Subramanian, R. Shankar; McLaughlin, John B.; Moumen, Nadjoua; Qian, Dongying

    2002-11-01

    A liquid drop present on a solid surface can move because of a gradient in wettability along the surface, as manifested by a gradient in the contact angle. The contact angle at a given point on the contact line between a solid and a liquid in a gaseous medium is the angle between the tangent planes to the liquid and the solid surfaces at that point and is measured within the liquid side, by convention. The motion of the drop occurs in the direction of increasing wettability. The cause of the motion is the net force exerted on the drop by the solid surface because of the variation of the contact angle around the periphery. This force causes acceleration of an initially stationary drop, and leads to its motion in the direction of decreasing contact angle. The nature of the motion is determined by the balance between the motivating force and the resisting hydrodynamic force from the solid surface and the surrounding gaseous medium. A wettability gradient can be chemically induced as shown by Chaudhury and Whitesides who provided unambiguous experimental evidence that drops can move in such gradients. The phenomenon can be important in heat transfer applications in low gravity, such as when condensation occurs on a surface. Daniel et al have demonstrated that the velocity of a drop on a surface due to a wettability gradient in the presence of condensation can be more than two orders of magnitude larger than that observed in the absence of condensation. In the present research program, we have begun to study the motion of a drop in a wettability gradient systematically using a model system. Our initial efforts will be restricted to a system in which no condensation occurs. The experiments are performed as follows. First, a rectangular strip of approximate dimensions 10 x 20 mm is cut out of a silicon wafer. The strip is cleaned thoroughly and its surface is exposed to the vapor from an alkylchlorosilane for a period lasting between one and two minutes inside a

  11. Drop jumping. II. The influence of dropping height on the biomechanics of drop jumping

    NARCIS (Netherlands)

    Bobbert, M F; Huijing, P A; van Ingen Schenau, G J

    In the literature, athletes preparing for explosive activities are recommended to include drop jumping in their training programs. For the execution of drop jumps, different techniques and different dropping heights can be used. This study was designed to investigate for the performance of bounce

  12. Hanging-wall deformation above a normal fault: sequential limit analyses

    Science.gov (United States)

    Yuan, Xiaoping; Leroy, Yves M.; Maillot, Bertrand

    2015-04-01

    The deformation in the hanging wall above a segmented normal fault is analysed with the sequential limit analysis (SLA). The method combines some predictions on the dip and position of the active fault and axial surface, with geometrical evolution à la Suppe (Groshong, 1989). Two problems are considered. The first followed the prototype proposed by Patton (2005) with a pre-defined convex, segmented fault. The orientation of the upper segment of the normal fault is an unknown in the second problem. The loading in both problems consists of the retreat of the back wall and the sedimentation. This sedimentation starts from the lowest point of the topography and acts at the rate rs relative to the wall retreat rate. For the first problem, the normal fault either has a zero friction or a friction value set to 25o or 30o to fit the experimental results (Patton, 2005). In the zero friction case, a hanging wall anticline develops much like in the experiments. In the 25o friction case, slip on the upper segment is accompanied by rotation of the axial plane producing a broad shear zone rooted at the fault bend. The same observation is made in the 30o case, but without slip on the upper segment. Experimental outcomes show a behaviour in between these two latter cases. For the second problem, mechanics predicts a concave fault bend with an upper segment dip decreasing during extension. The axial surface rooting at the normal fault bend sees its dips increasing during extension resulting in a curved roll-over. Softening on the normal fault leads to a stepwise rotation responsible for strain partitioning into small blocks in the hanging wall. The rotation is due to the subsidence of the topography above the hanging wall. Sedimentation in the lowest region thus reduces the rotations. Note that these rotations predicted by mechanics are not accounted for in most geometrical approaches (Xiao and Suppe, 1992) and are observed in sand box experiments (Egholm et al., 2007, referring

  13. Suicidal hanging donors for lung transplantation: Is this chapter still closed? Midterm experience from a single center in United Kingdom.

    Science.gov (United States)

    Ananiadou, Olga; Schmack, Bastian; Zych, Bartlomiej; Sabashnikov, Anton; Garcia-Saez, Diana; Mohite, Prashant; Weymann, Alexander; Mansur, Ashham; Zeriouh, Mohamed; Marczin, Nandor; De Robertis, Fabio; Simon, Andre Rüdiger; Popov, Aron-Frederik

    2018-04-01

    In the context of limited donor pool in cardiothoracic transplantation, utilization of organs from high risk donors, such as suicidal hanging donors, while ensuring safety, is under consideration. We sought to evaluate the outcomes of lung transplantations (LTx) that use organs from this group.Between January 2011 and December 2015, 265 LTx were performed at our center. Twenty-two recipients received lungs from donors after suicidal hanging (group 1). The remaining 243 transplantations were used as a control (group 2). Analysis of recipient and donor characteristics as well as outcomes was performed.No statistically significant difference was found in the donor characteristics between analyzed groups, except for higher incidence of cardiac arrest, younger age and smoking history of hanging donors (P donor cause of death is not associated with poor mid-term survival or chronic lung allograft dysfunction following transplantation. These results encourage assessment of lungs from hanging donors, and their consideration for transplantation.

  14. First drop dissimilarity in drop-on-demand inkjet devices

    International Nuclear Information System (INIS)

    Famili, Amin; Palkar, Saurabh A.; Baldy, William J. Jr.

    2011-01-01

    As inkjet printing technology is increasingly applied in a broader array of applications, careful characterization of its method of use is critical due to its inherent sensitivity. A common operational mode in inkjet technology known as drop-on-demand ejection is used as a way to deliver a controlled quantity of material to a precise location on a target. This method of operation allows ejection of individual or a sequence (burst) of drops based on a timed trigger event. This work presents an examination of sequences of drops as they are ejected, indicating a number of phenomena that must be considered when designing a drop-on-demand inkjet system. These phenomena appear to be driven by differences between the first ejected drop in a burst and those that follow it and result in a break-down of the linear relationship expected between driving amplitude and drop mass. This first drop, as quantified by high-speed videography and subsequent image analysis, can be different in morphology, trajectory, velocity, and volume from subsequent drops within a burst. These findings were confirmed orthogonally by both volume and mass measurement techniques which allowed quantitation down to single drops.

  15. Importance of tissue biopsy in suicidal hanging deaths

    Directory of Open Access Journals (Sweden)

    Manal S. Bamousa

    2015-12-01

    The total number of cases was 62; 85.5% of the deceased were males, while 15% were females. The majority of cases (53% were among the age group of 20–30 years. Hemorrhage of the sternocleidomastoid muscle and carotid intimal tear were both found in 90% of cases. Thyroid congestion was detected in 91%, and Hashimoto’s thyroiditis was diagnosed in 2% of studied cases. The study discusses the importance of biopsy examination in hanging deaths and compares its results with other similar previous studies.

  16. Measurement and correlation of frictional pressure drop of refrigerant-based nanofluid flow boiling inside a horizontal smooth tube

    Energy Technology Data Exchange (ETDEWEB)

    Peng, Hao; Ding, Guoliang; Jiang, Weiting; Hu, Haitao [Institute of Refrigeration and Cryogenics, Shanghai Jiaotong University, 800 Dongchuan Road, Shanghai 200240 (China); Gao, Yifeng [International Copper Association Shanghai Office, 381 Huaihaizhong Road, Shanghai 200020 (China)

    2009-11-15

    The objective of this paper is to investigate the effect of nanoparticle on the frictional pressure drop characteristics of refrigerant-based nanofluid flow boiling inside a horizontal smooth tube, and to present a correlation for predicting the frictional pressure drop of refrigerant-based nanofluid. R113 refrigerant and CuO nanoparticle were used for preparing refrigerant-based nanofluid. Experimental conditions include mass fluxes from 100 to 200 kg m{sup -2} s{sup -1}, heat fluxes from 3.08 to 6.16 kW m{sup -2}, inlet vapor qualities from 0.2 to 0.7, and mass fractions of nanoparticles from 0 to 0.5 wt%. The experimental results show that the frictional pressured drop of refrigerant-based nanofluid increases with the increase of the mass fraction of nanoparticles, and the maximum enhancement of frictional pressure drop is 20.8% under above conditions. A frictional pressure drop correlation for refrigerant-based nanofluid is proposed, and the predictions agree with 92% of the experimental data within the deviation of {+-}15%. (author)

  17. Foraging of the Indian Short-nosed Fruit Bat Cynopterus sphinx on banana in shops and on the pieces dropped by monkeys at a temple

    Directory of Open Access Journals (Sweden)

    A. Rathinakumar

    2016-11-01

    Full Text Available The Indian Short-nosed Fruit Bat Cynopterus sphinx fed on the pieces of banana fruit that were dropped by monkeys on the tower of a temple and in nearby shops.  The monkeys obtained fruits from devotees and shop owners.  The peak number of bat visits occurred during pre- and post- midnight hours at the tower and shops, respectively, coinciding with the lights off situation and reduced human disturbance.  The bats landed on bunches of ripe bananas hanging in the front of shops.  The number of bat landings on the tower was greater than that in the shops.  The overall number of bat visits were higher during October when compared to other periods of the year.  This may be due to the occurrence of more festivals during October.  Our study is an example of opportunistic feeding, in which banana pieces dropped while monkeys were feeding on them were eaten by the bats.

  18. [A homicidal strangulation by ligature, disguised as a suicidal hanging].

    Science.gov (United States)

    Ueno, Y; Fukunaga, T; Nakagawa, K; Imabayashi, T; Fujiwara, S; Adachi, J; Mizoi, Y

    1989-02-01

    A naked 38-year-old woman was found dead, lying beside a bed in a guest room of a hotel. A cotton cord was looped around her neck, with one end tied to a bedpost. Thus it seemed that she had hanged herself in a lying position. Yet, certain suspicious factors gave rise to doubts. The hair and a necklace were intertwined with the cord and a man that had been staying in the same room had fled. On the postmortem examination, marked congestion and many petechial haemorrhages were seen in the face and the upper area of the neck, also in conjunctiva. A light-brown and highly dry ligature mark, about one centimeter in width, was found on the neck. The mark, crossing the front of the neck, was clearly evident from the back to the right side of the neck. The lower borders of the congestion and petechial haemorrhages in the face and neck were located 1 or 2 centimeters above the ligature mark. On the left side of the neck, another pale ligature mark with slight subcutaneous haemorrhages was seen between the dry mark and the lower border of the congested part of the neck. A similar ligature mark also was found on the back of the neck. On internal examination, congestion of the cervical lymph nodes and haemorrhages in the cervical muscles were recognized in the areas of the cutaneous congestion. These findings supported suspicions that the dry ligature mark had been caused by hanging after her death, and that the light ligature mark with slight subcutaneous haemorrhages on the left side and back of the neck had been caused by strangulation, which had brought on the victim's death. Therefore, it was decided that her death had been disguised as a suicidal hanging, after she had been strangled by ligature. A week later, her former husband was arrested and confessed his crime.

  19. Liver hanging maneuver for right hemiliver in situ donation--anatomical considerations.

    Science.gov (United States)

    Trotovsek, B; Gadzijev, E M; Ravnik, D; Hribernik, M

    2006-01-01

    An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4-6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. One hundred corrosive casts of livers were evaluated to establish the position and diameter of short subhepatic veins and the inferior right hepatic vein. The average distance from the right border of the inferior vena cava to the opening of segment 1 veins was 16.7+/-3.4 mm and to the entrance of segment 9 veins was 5.0+/-0.5 mm. The width of the narrowest point on the route of blind dissection was determined, with the average value being 8.7+/-2.3 mm (range 2-15 mm). The results show that the liver hanging maneuver is a safe procedure. A proposed route of dissection minimizes the risk of disrupting short subhepatic veins (7%).

  20. THE BEHAVIOURAL REACTION OF WEANERS TO HANGING TOYS: WOODEN BALL AND AROMATIZED WOODEN BALL – WAY TO REDUCE AGGRESSION AFTER MIXING

    Directory of Open Access Journals (Sweden)

    Jacek NOWICKI

    2008-05-01

    Full Text Available The behaviour of weaners after mixing housed in pens equipped with hanging wooden ball, aromatized with vanilla fluid hanging wooden ball and without enrichment was evaluated. It was found that both enrichments reduced aggression, however the most interesting for weaners was the aromatized wooden ball.

  1. Phase diagram of nanoscale alloy particles used for vapor-liquid-solid growth of semiconductor nanowires.

    Science.gov (United States)

    Sutter, Eli; Sutter, Peter

    2008-02-01

    We use transmission electron microscopy observations to establish the parts of the phase diagram of nanometer sized Au-Ge alloy drops at the tips of Ge nanowires (NWs) that determine their temperature-dependent equilibrium composition and, hence, their exchange of semiconductor material with the NWs. We find that the phase diagram of the nanoscale drop deviates significantly from that of the bulk alloy, which explains discrepancies between actual growth results and predictions on the basis of the bulk-phase equilibria. Our findings provide the basis for tailoring vapor-liquid-solid growth to achieve complex one-dimensional materials geometries.

  2. A three-dimensional in vitro HepG2 cells liver spheroid model for genotoxicity studies.

    Science.gov (United States)

    Shah, Ume-Kulsoom; Mallia, Jefferson de Oliveira; Singh, Neenu; Chapman, Katherine E; Doak, Shareen H; Jenkins, Gareth J S

    2018-01-01

    The liver's role in metabolism of chemicals makes it an appropriate tissue for toxicity testing. Current testing protocols, such as animal testing and two-dimensional liver cell systems, offer limited resemblance to in vivo liver cell behaviour, in terms of gene expression profiles and metabolic competence; thus, they do not always accurately predict human toxicology. In vitro three-dimensional liver cell models offer an attractive alternative. This study reports on the development of a 3D liver model, using HepG2 cells, by a hanging-drop technique, with a focus on evaluating spheroid growth characteristics and suitability for genotoxicity testing. The cytokinesis-blocked micronucleus assay protocol was adapted to enable micronucleus (MN) detection in the 3D spheroid models. This involved evaluating the difference between hanging vs non-hanging drop positions for dosing of the test agents and comparison of automated Metafer scoring with manual scoring for MN detection in HepG2 spheroids. The initial seeding density, used for all experiments, was 5000 cells/20 μl drop hanging spheroids, harvested on day 4, with >75% cell viability. Albumin secretion (7.8 g/l) and both CYP1A1 and CYP1A2 gene expression were highest in the 3D environment at day 4. Exposure to metabolically activated genotoxicants for 24 h resulted in a 6-fold increase in CYP1A1 enzyme activity (3 μM B[a]P) and a 30-fold increase in CYP1A2 enzyme activity (5 μM PhIP) in 3D hanging spheroids. MN inductions in response to B[a]P or PhIP were 2-fold and 3-fold, respectively, and were greater in 3D hanging spheroids than in 2D format, showing that hanging spheroids are more sensitive to genotoxic agents. HepG2 hanging-drop spheroids are an exciting new alternative system for genotoxicity studies, due to their improved structural and physiological properties, relative to 2D cultures. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. From drop impact physics to spray cooling models: a critical review

    Science.gov (United States)

    Breitenbach, Jan; Roisman, Ilia V.; Tropea, Cameron

    2018-03-01

    Spray-wall interaction is an important process encountered in a large number of existing and emerging technologies and is the underlying phenomenon associated with spray cooling. Spray cooling is a very efficient technology, surpassing all other conventional cooling methods, especially those not involving phase change and not exploiting the latent heat of vaporization. However, the effectiveness of spray cooling is dependent on a large number of parameters, including spray characteristics like drop size, velocity and number density, the surface morphology, but also on the temperature range and thermal properties of the materials involved. Indeed, the temperature of the substrate can have significant influence on the hydrodynamics of drop and spray impact, an aspect which is seldom considered in model formulation. This process is extremely complex, thus most design rules to date are highly empirical in nature. On the other hand, significant theoretical progress has been made in recent years about the interaction of single drops with heated walls and improvements to the fundamentals of spray cooling can now be anticipated. The present review has the objective of summarizing some of these recent advances and to establish a framework for future development of more reliable and universal physics-based correlations to describe quantities involved in spray cooling.

  4. Evaluation of a hanging core support concept for LMR application

    International Nuclear Information System (INIS)

    Burelbach, J.P.; Cha, B.K.; Huebotter, P.R.; Kann, W.J.; Pan, Y.C.; Saiveau, J.G.; Seidensticker, R.W.; Wu, T.S.

    1985-01-01

    The paper describes an innovative design concept for a liquid metal reactor (LMR) core support structure (CSS). A hanging core support structure is described and analyzed. The design offers inherent safety features, constructability advantages, and potential cost reductions. Some safety considerations are examined which include the in-service inspection (ISI), the backup support system and the structural behavior in a hypothetical case of a broken beam in the core support structure

  5. Cells on Gels: Cell Behavior at the Air-Gel Interface

    Science.gov (United States)

    O'Bryan, Christopher; Hormel, Tristan; Bhattacharjee, Tapomoy; Sawyer, W.; Angelini, Thomas

    Numerous different types of cells are often grown at air-liquid interfaces. For example, a common way to create cell spheroids is to disperse cells in a droplet of liquid media that hangs from the lid of a culture dish - the ``hanging drop'' method. Some types of epithelial cells form monolayers at the bottom of hanging drops, instead of spheroids. Corneal epithelial cells stratify and exhibit a tissue-like phenotype when attached to liquid permeable culture surfaces positioned at the air-liquid media interface (air-lifted culture). These widely used culture methods make experimentation challenging - imaging through hanging drops and air-lifted culture dishes is prohibitive. However, similar results may be achieved by culturing cells on hydrogel surfaces at the air-gel interface. In this talk we will describe a method for culturing cells at air-gel interfaces. We seed human corneal epithelial cells (hTCEpi) onto the surfaces of hydrogel networks and jammed microgels, exposed to air. Preliminary observations of cell behavior at the air-gel interface will be presented.

  6. Vapor pressures and enthalpies of vaporization of azides

    International Nuclear Information System (INIS)

    Verevkin, Sergey P.; Emel'yanenko, Vladimir N.; Algarra, Manuel; Manuel Lopez-Romero, J.; Aguiar, Fabio; Enrique Rodriguez-Borges, J.; Esteves da Silva, Joaquim C.G.

    2011-01-01

    Highlights: → We prepared and measured vapor pressures and vaporization enthalpies of 7 azides. → We examined consistency of new and available in the literature data. → Data for geminal azides and azido-alkanes selected for thermochemical calculations. - Abstract: Vapor pressures of some azides have been determined by the transpiration method. The molar enthalpies of vaporization Δ l g H m of these compounds were derived from the temperature dependencies of vapor pressures. The measured data sets were successfully checked for internal consistency by comparison with vaporization enthalpies of similarly structured compounds.

  7. Drop Impact Dynamics with Sessile Drops and Geometries: Spreading, Jetting, and Fragmentation

    Science.gov (United States)

    Tilger, Christopher F.

    The tendency of surface tension to cause small parcels of fluid to form into drops allows convenient packaging, transport, dispersal of liquid phase matter. Liquid drop impacts with solids, liquids, and other drops have realized and additional future applications in biological, manufacturing, heat transfer, and combustion systems. Experiments were conducted to investigate the dynamics of multiple drop collisions, rather than the most-studied phenomenon of single drop impacts. Additional drop impacts were performed on rigid hemispheres representing sessile drops, angled substrates, and into the vertex of two tilted surfaces arranged into a vee shape. A qualitative inspection of drop-sessile drop impacts shows distinct post-impact shapes depending on the offset distance between the drops. At intermediate offset distances, distinct jets issue from the overlap region between the two drops projected areas. These jets are observed to reach their maximum extent at a critical offset distance ratio, epsilon epsilon ˜ 0.75-0.80, with substrate contact angle and W e having a lesser effect. Capillary waves that traverse the sessile drop after collision cause a lower aspect ratio liquid column to emanate from the sessile drop opposite the impact. In order to better understand the jetting phenomenon seen in the offset drop-sessile drop impacts, simpler solid geometries are investigated that elicit a similar behavior. Solid hemispheres do not show the singular jetting observed in the fluidic case, however, a simple vee formed by two intersection planar substrates do jet in a similar fashion to the fluidic case. A geometric model with partnered experiments is developed to describe the bisymmetric spread of an impacting drop on an angled substrate. This geometric model is used to guide a time of arrival based model for various features of the drop impact, which is used to predict jetting in various vee channel experiments.

  8. Effect of loose spring skirt mounting position on vibration damping in a multi segment hanging cantilever

    International Nuclear Information System (INIS)

    Nazeer, M.M.; Khan, A.F.; Shah, R.H; Afzal, M.; Ahmed, N.

    2001-01-01

    The loose spring skirt clearance is the major factor effecting the damping and amplitude control of randomly excited vibrations in a vertically hanging cantilever. However, the spring's mounting position also has an important role to play. In this work, the results of computational model as well as that of experimental set-up for various spring mounting positions having optimum annular clearance between skirted member and the skirt are presented and their vibration damping response is analyzed. It is observed that lower is the mounting position, the better is the damping and its maximum value is attained when the bottom end of spring skirt and the hanging cantilever are mutually flushed. (author)

  9. Liquid--liquid contact in vapor explosion

    International Nuclear Information System (INIS)

    Segev, A.

    1978-08-01

    The contact of two liquid materials, one of which is at a temperature substantially above the boiling point of the other, can lead to fast energy conversion and a subsequent shock wave. This well-known phenomenon is called a ''vapor explosion.'' One method of producing intimate, liquid--liquid contact (which is known to be a necessary condition for vapor explosion) is a shock tube configuration. Such experiments in which water was impacted upon molten aluminum showed that very high pressures, even larger than the thermodynamic critical pressure, could occur. The mechanism by which such sharp pressure pulses are generated is not yet clear. In this experiment cold liquids (Freon-11, Freon-22, water, or butanol) were impacted upon various hot materials (mineral oil, silicone oil, water, mercury, molten Wood's metal or molten salt mixture). The main conclusion from the experimental study is that hydrodynamic effects may be very significant in any shock tube analyses, especially when multiple interactions are observed. A theoretical study was performed to check the possibility of vapor film squeezing (between a drop in film boiling and a surface) as a controlling mechanism for making liquid--liquid contact. Using experimental data, the film thickness was calculated and it was found to be too thick for any conceivable film rupture mechanism. It was suggested that the coalescence is a two-stage process, in which the controlling stage depends mainly on temperature and surface properties and can be described as the ability of cold liquid to spread on a hot surface

  10. Design of 3D printed insert for hanging culture of Caco-2 cells

    International Nuclear Information System (INIS)

    Shen, Chong; Meng, Qin; Zhang, Guoliang

    2015-01-01

    A Caco-2 cell culture on Transwell, an alternative testing to animal or human testing used in evaluating drug intestinal permeability, incorrectly estimated the absorption of actively transported drugs due to the low expression of membrane transporters. Similarly, three-dimensional (3D) cultures of Caco-2 cells, which have been recommended to be more physiological relevant, were not superior to the Transwell culture in either accuracy or convenience in drug permeability testing. Using rapid 3D printing prototyping techniques, this study proposed a hanging culture of Caco-2 cells that performed with high accuracy in predicting drug permeability in humans. As found, hanging cultured Caco-2 cells formed a confluent monolayer and maintained high cell viability on the 3D printed insert. Compared with the normal culture on Transwell, the Caco-2 cells on the 3D printed insert presented ∼30–100% higher brush border enzyme activity and ∼2–7 folds higher activity of P-glycoprotein/multidrug resistance-associated protein 2 during 21 days of incubation. For the eight membrane transporter substrates, the predictive curve of the 3D printing culture exhibited better linearity (R 2  = 0.92) to the human oral adsorption than that of the Transwell culture (R 2  = 0.84), indicating better prediction by the 3D printing culture. In this regard, the 3D printed insert for hanging culture could be potentially developed as a convenient and low-cost tool for testing drug oral absorption. (paper)

  11. Low flow velocity, fine-screen heat exchangers and vapor-cooled cryogenic current leads

    International Nuclear Information System (INIS)

    Steyert, W.A.; Stone, N.J.

    1978-09-01

    The design, construction, and testing of three compact, low temperature heat exchangers are reported. A method is given for the construction of a small (approximately = 20-cm 3 volume) exchanger that can handle 6 g/s helium flow with low pressure drops (ΔP/P = 10 percent) and adequate heat transfer (N/sub tu/ = 3). The use of screen for simple, vapor-cooled current leads into cryogenic systems is also discussed

  12. On the equilibrium contact angle of sessile liquid drops from molecular dynamics simulations.

    Science.gov (United States)

    Ravipati, Srikanth; Aymard, Benjamin; Kalliadasis, Serafim; Galindo, Amparo

    2018-04-28

    We present a new methodology to estimate the contact angles of sessile drops from molecular simulations by using the Gaussian convolution method of Willard and Chandler [J. Phys. Chem. B 114, 1954-1958 (2010)] to calculate the coarse-grained density from atomic coordinates. The iso-density contour with average coarse-grained density value equal to half of the bulk liquid density is identified as the average liquid-vapor (LV) interface. Angles between the unit normal vectors to the average LV interface and unit normal vector to the solid surface, as a function of the distance normal to the solid surface, are calculated. The cosines of these angles are extrapolated to the three-phase contact line to estimate the sessile drop contact angle. The proposed methodology, which is relatively easy to implement, is systematically applied to three systems: (i) a Lennard-Jones (LJ) drop on a featureless LJ 9-3 surface; (ii) an SPC/E water drop on a featureless LJ 9-3 surface; and (iii) an SPC/E water drop on a graphite surface. The sessile drop contact angles estimated with our methodology for the first two systems are shown to be in good agreement with the angles predicted from Young's equation. The interfacial tensions required for this equation are computed by employing the test-area perturbation method for the corresponding planar interfaces. Our findings suggest that the widely adopted spherical-cap approximation should be used with caution, as it could take a long time for a sessile drop to relax to a spherical shape, of the order of 100 ns, especially for water molecules initiated in a lattice configuration on a solid surface. But even though a water drop can take a long time to reach the spherical shape, we find that the contact angle is well established much faster and the drop evolves toward the spherical shape following a constant-contact-angle relaxation dynamics. Making use of this observation, our methodology allows a good estimation of the sessile drop contact

  13. Arbitrary-Level Hanging Nodes and Automatic Adaptivity in the hp-FEM

    Czech Academy of Sciences Publication Activity Database

    Šolín, Pavel; Červený, Jakub; Doležel, Ivo

    2008-01-01

    Roč. 77, č. 1 (2008), s. 117-132 ISSN 0378-4754 R&D Projects: GA ČR(CZ) GA102/07/0496; GA ČR GA102/05/0629; GA AV ČR IAA100760702 Institutional research plan: CEZ:AV0Z20570509 Keywords : constrained approximation * hanging nodes * hp-FEM Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.930, year: 2008

  14. Toxicology findings in cases of hanging in the City and County of San Francisco over the 3-year period from 2011 to 2013.

    Science.gov (United States)

    San Nicolas, A C; Lemos, N P

    2015-10-01

    In postmortem cases where the cause of death is hanging, toxicological analyses may be considered unnecessary by some medical examiners, toxicologists, and other persons involved in medico-legal investigations because the cause of death seems "obvious." To ascertain if toxicological analyses are necessary when the cause of death is hanging, all 102 hanging cases (25 females; 77 males) from 2011 to 2013 that came under the jurisdiction of the San Francisco Office of the Chief Medical Examiner were examined from a total of 3912 sudden, unexpected, or violent death cases in the same period. Suicide was the manner of death in 99 of these cases, with two accidental and one undetermined death. The average age of decedents was 43.9 years (median 41), the youngest was an 11-year old male and the oldest was an 86-year old female. Of the 102 cases, 33 had negative toxicology while 69 cases had at least one positive toxicology result. Females were equally likely to have negative or positive results (12 and 13 cases respectively), but males were 37.5% more likely to have positive toxicology (n=56) rather than negative toxicology (n=21). For females, alcohol, mirtazapine, venlafaxine, and trazodone were the top psychoactive substances in peripheral blood while THC, cocaine, hydrocodone, bupropion, olanzapine, doxylamine, quetiapine and dextromethorphan were also reported. For males, alcohol, THC, cocaine, amphetamine, methamphetamine, bupropion, and diphenhydramine were the top psychoactive substances in blood, but several other drugs were also found in individual cases. Our study of hanging cases over a 3-year period support the idea that complete postmortem toxicology investigation of hangings should be performed, even when the "obvious" cause of death is asphyxia due to hanging. Many of these cases involved psychoactive substances (most often alcohol and cannabis), and having such knowledge provides a better understanding of the circumstances surrounding the decedent's death

  15. Comparison of boiling heat transfer coefficient and pressure drop correlations for evaporators

    International Nuclear Information System (INIS)

    Eskin, N.; Arslan, G.

    2009-01-01

    Evaporator design is an important aspect for the HVAC industry. As the demand for more efficient and compact heat exchangers increase, researches on estimation of two-phase flow heat transfer and pressure drop gain importance. Due to complexity of the hydrodynamic and heat transfer of the two-phase flow, there are many experimental studies available for refrigerants int he literature. In this study, a model for boiling heat transfer in a horizontal tube has been developed and the simulation results are compared with experimental ones published in the literature. In these comparisons, heat transfer coefficient is calculated by using Kattan-Thome-Favrat (1998), Shah (1982), Kandilikar (1990), Chaddock and Brunemann (1967) correlations under different operational conditions such as saturation pressure, mass flux, the type of refrigerant and two phase flow pattern. Besides that flow pattern has also been considered in the simulation by using Thome and El Hajal (2002) model. For pressure drop Lockhart-Martinelli (1949), Mueller-Steinhagen-Hack (1986) and Groennerund (1979) correlations are used in simulations. Local vapor quality change at each experimental condition through the model is determined. Roughness is an important parameter for frictional pressure drop. Friction coefficient is determined by using Churchill (1977) model. (author)

  16. Water vapor permeation and dehumidification performance of poly(vinyl alcohol)/lithium chloride composite membranes

    KAUST Repository

    Bui, Duc Thuan

    2015-10-09

    Thin and robust composite membranes comprising stainless steel scaffold, fine and porous TiO2 and polyvinyl alcohol/lithium chloride were fabricated and studied for air dehumidification application. Higher hydrophilicity, sorption and permeation were observed for membranes with increased lithium chloride content up to 50%. The permeation and sorption properties of the membranes were investigated under different temperatures. The results provided a deeper insight into the membrane water vapor permeation process. It was specifically noted that lithium chloride significantly reduces water diffusion energy barrier, resulting in the change of permeation energy from positive to negative values. Higher water vapor permeance was observed for the membrane with higher LiCl content at lower temperature. The isothermal air dehumidification tests show that the membrane is suitable for dehumidifying air in high humid condition. Additionally, results also indicate a trade-off between the humidity ratio drop with the water vapor removal rate when varying air flowrate.

  17. Monitoring the variability of precipitable water vapor over the Klang Valley, Malaysia during flash flood

    International Nuclear Information System (INIS)

    Suparta, W; Rahman, R; Singh, M S J

    2014-01-01

    Klang Valley is a focal area of Malaysian economic and business activities where the local weather condition is very important to maintain its reputation. Heavy rainfalls for more than an hour were reported up to 40 mm in September 2013 and 35 mm in October 2013. Both events are monitored as the first and second cases of flash flood, respectively. Based on these cases, we investigate the water vapor, rainfall, surface meteorological data (surface pressure, relative humidity, and temperature) and river water level. The precipitable water vapor (PWV) derived from Global Positioning System (GPS) is used to indicate the impact of flash flood on the rainfall. We found that PWV was dropped 4 mm in 2 hours before rainfall reached to 40 mm and dropped 3 mm in 3 hours before 35 mm of rainfall in respective cases. Variation of PWV was higher in September case compared to October case of about 2 mm. We suggest the rainfall phenomena can disturb the GPS propagation and therefore, the impact of PWV before, during and after the flash flood event at three selected GPS stations in Klang Valley is investigated for possible mitigation in the future

  18. Description of the heating and expansion process of a water drop enclosed in a hot melt

    International Nuclear Information System (INIS)

    Froehlich, G.; Berg, E. von.

    1985-11-01

    In the present study a simple model for the description of the heating- and expansion-process of a water drop enclosed in hot melt is developed. The model is valid between the first contact of melt and water up to the beginning of evaporation. A possible superheating by retardation of ebullition is disregarded. The balance equations for energy, mass and momentum as well as the equation of state are integrated over the radial space coordinate in both media using appropriate profiles of temperature, pressure and velocity. Thereby a system of coupled ordinary differential equations is formed for the variables of the model which are now time dependent only. The equations are solved numerically by means of a FORTRAN-program. The influence of parameters (melt-temperature, heat-transfer-coefficient between melt and water as well as drop radius) are studied. It is shown that always very rapidly a vapor-layer forms around the water drop, while the inner part of the drop did not yet 'notice' anything of the heating process. An approximation formula for the time-transfer-coefficients between melt and water. Due to this approximation, the time up to incipience of evaporation grows proportional to the drop radius, which means that in the frame of the present model even small droplets won't evaporate as a whole instantaneously. (orig.) [de

  19. Crystallization of the pneumococcal autolysin LytC: in-house phasing using novel lanthanide complexes

    International Nuclear Information System (INIS)

    Pérez-Dorado, Inmaculada; Sanles, Reyes; González, Ana; García, Pedro; García, José L.; Martínez-Ripoll, Martín; Hermoso, Juan A.

    2010-01-01

    The complete pneumococcal autolysin LytC has been crystallized by the hanging-drop vapor-diffusion method. A SAD data set has been collected in-house from a Gd derivative up to 2.6 Å resolution. LytC, one of the major autolysins from the human pathogen Streptococcus pneumoniae, has been crystallized as needles by the hanging-drop technique using 10%(w/v) PEG 3350 as precipitant and 10 mM HEPES pH 7.5. LytC crystals were quickly soaked in mother liquor containing 2 mM of the complex Gd-HPDO3A to produce derivatized crystals (LytC Gd-HPDO3A ). Both native LytC and isomorphous LytC Gd-HPDO3A crystals were flash-cooled in a nitrogen flow at 120 K prior to X-ray data collection using an in-house Enraf–Nonius rotating-anode generator (λ = 1.5418 Å) and a MAR345 imaging-plate detector. In both cases, good-quality diffraction patterns were obtained at high resolution. LytC Gd-HPDO3A crystals allowed the collection of a SAD X-ray data set to 2.6 Å resolution indexed in terms of a P2 1 monoclinic unit cell with parameters a = 59.37, b = 67.16, c = 78.85 Å, β = 105.69°. The anomalous Patterson map allowed the identification of one heavy-atom binding site, which was sufficient for the calculation of an interpretable anomalous map at 2.6 Å resolution

  20. Gasification of biomass in a drop tube furnace. Foergasning av biomassa i fallroersreaktor

    Energy Technology Data Exchange (ETDEWEB)

    Hallgren, A; Andersson, L A; Bjerle, I [Lund Univ. (SE). Dept. of Chemical Engineering 2

    1989-11-01

    The aim of the present investigation of steam gasification is mainly to study the influence on gas production (quantity, composition) for different temperatures, dwells, and partial pressure of steam and nitrogen in a drop tube furnace. The range of temperature in the experiments was 1000-1400 deg C, range of dwell 0.25-1 sec, and range of water vapor/nitrogen partial pressure ratio 25/75 to 75/25. The degree of burnup increases with increasing dwell. Highest burnup is found at the highest tmperatures. In CO{sub 2} atmosphere the degree of burnup is slightly higher than in N{sub 2} atmosphere. In the steam experiments is shown that a long dwell as well as a high water vapor partial pressure increases burnup. The product gas consists mainly of carbon monoxide and hydrogen, but ca 10% each of carbon dioxide and methane are also found. Hydrocarbons like ethene, acetylene and ethane are also found, but only in a total amount of less than 5%. The experiments in water vapor atmosphere show that a change in steam partial pressure has a very small effect on the composition of the product gas for the temperature range studied. (O.S.) (7 figs.).

  1. Measurement of the Mass of an Object Hanging from a Spring--Revisited

    Science.gov (United States)

    Serafin, Kamil; Oracz, Joanna; Grzybowski, Marcin; Koperski, Maciej; Sznajder, Pawel; Zinkiewicz, Lukasz; Wasylczyk, Piotr

    2012-01-01

    In an open competition, students were to determine the mass of a metal cylinder hanging on a spring inside a transparent enclosure. With the time for experiments limited to 24 h due to the unexpectedly large number of participants, a few surprisingly accurate results were submitted, the best of them differing by no more than 0.5% from the true…

  2. Expression, purification, crystallization and preliminary X-ray analysis of Pseudomonas aeruginosa AlgX

    Energy Technology Data Exchange (ETDEWEB)

    Weadge, J.T.; Robinson, H.; Yip, P. P.; Arnett, K.; Tipton, P. A.; Howell, P. L.

    2010-05-01

    AlgX is a periplasmic protein required for the production of the exopolysaccharide alginate in Pseudomonas sp. and Azotobacter vinelandii. AlgX has been overexpressed and purified and diffraction-quality crystals have been grown using iterative seeding and the hanging-drop vapor-diffusion method. The crystals grew as flat plates with unit-cell parameters a = 46.4, b = 120.6, c = 86.9 {angstrom}, {beta} = 95.7{sup o}. The crystals exhibited the symmetry of space group P2{sub 1} and diffracted to a minimum d-spacing of 2.1 {angstrom}. On the basis of the Matthews coefficient (V{sub M} = 2.25 {angstrom}{sup 3} Da{sup -1}), two molecules were estimated to be present in the asymmetric unit.

  3. Nonlinear response of tropical lower-stratospheric temperature and water vapor to ENSO

    Directory of Open Access Journals (Sweden)

    C. I. Garfinkel

    2018-04-01

    Full Text Available A series of simulations using the NASA Goddard Earth Observing System Chemistry–Climate Model are analyzed in order to aid in the interpretation of observed interannual and sub-decadal variability in the tropical lower stratosphere over the past 35 years. The impact of El Niño–Southern Oscillation on temperature and water vapor in this region is nonlinear in boreal spring. While moderate El Niño events lead to cooling in this region, strong El Niño events lead to warming, even as the response of the large-scale Brewer–Dobson circulation appears to scale nearly linearly with El Niño. This nonlinearity is shown to arise from the response in the Indo-West Pacific to El Niño: strong El Niño events lead to tropospheric warming extending into the tropical tropopause layer and up to the cold point in this region, where it allows for more water vapor to enter the stratosphere. The net effect is that both strong La Niña and strong El Niño events lead to enhanced entry water vapor and stratospheric moistening in boreal spring and early summer. These results lead to the following interpretation of the contribution of sea surface temperatures to the decline in water vapor in the early 2000s: the very strong El Niño event in 1997/1998, followed by more than 2 consecutive years of La Niña, led to enhanced lower-stratospheric water vapor. As this period ended in early 2001, entry water vapor concentrations declined. This effect accounts for approximately one-quarter of the observed drop.

  4. Nonlinear response of tropical lower-stratospheric temperature and water vapor to ENSO

    Science.gov (United States)

    Garfinkel, Chaim I.; Gordon, Amit; Oman, Luke D.; Li, Feng; Davis, Sean; Pawson, Steven

    2018-04-01

    A series of simulations using the NASA Goddard Earth Observing System Chemistry-Climate Model are analyzed in order to aid in the interpretation of observed interannual and sub-decadal variability in the tropical lower stratosphere over the past 35 years. The impact of El Niño-Southern Oscillation on temperature and water vapor in this region is nonlinear in boreal spring. While moderate El Niño events lead to cooling in this region, strong El Niño events lead to warming, even as the response of the large-scale Brewer-Dobson circulation appears to scale nearly linearly with El Niño. This nonlinearity is shown to arise from the response in the Indo-West Pacific to El Niño: strong El Niño events lead to tropospheric warming extending into the tropical tropopause layer and up to the cold point in this region, where it allows for more water vapor to enter the stratosphere. The net effect is that both strong La Niña and strong El Niño events lead to enhanced entry water vapor and stratospheric moistening in boreal spring and early summer. These results lead to the following interpretation of the contribution of sea surface temperatures to the decline in water vapor in the early 2000s: the very strong El Niño event in 1997/1998, followed by more than 2 consecutive years of La Niña, led to enhanced lower-stratospheric water vapor. As this period ended in early 2001, entry water vapor concentrations declined. This effect accounts for approximately one-quarter of the observed drop.

  5. [Optimize dropping process of Ginkgo biloba dropping pills by using design space approach].

    Science.gov (United States)

    Shen, Ji-Chen; Wang, Qing-Qing; Chen, An; Pan, Fang-Lai; Gong, Xing-Chu; Qu, Hai-Bin

    2017-07-01

    In this paper, a design space approach was applied to optimize the dropping process of Ginkgo biloba dropping pills. Firstly, potential critical process parameters and potential process critical quality attributes were determined through literature research and pre-experiments. Secondly, experiments were carried out according to Box-Behnken design. Then the critical process parameters and critical quality attributes were determined based on the experimental results. Thirdly, second-order polynomial models were used to describe the quantitative relationships between critical process parameters and critical quality attributes. Finally, a probability-based design space was calculated and verified. The verification results showed that efficient production of Ginkgo biloba dropping pills can be guaranteed by operating within the design space parameters. The recommended operation ranges for the critical dropping process parameters of Ginkgo biloba dropping pills were as follows: dropping distance of 5.5-6.7 cm, and dropping speed of 59-60 drops per minute, providing a reference for industrial production of Ginkgo biloba dropping pills. Copyright© by the Chinese Pharmaceutical Association.

  6. Modeling the fine fragmentation following the triggering stage of a vapor explosion

    International Nuclear Information System (INIS)

    Darbord, I.

    1997-01-01

    In the frame of PWR severe accidents, where the core melt, this thesis studies one of the stages of an FCI (fuel coolant interaction) or vapor explosion. An FCI is a rapid evaporation of a coolant when it comes into contact with a hot liquid. More precisely, the subject of this study is the triggering stage of the FCI, when a fuel drop of diameter around one centimeter breaks up into many fragments, diameter of which is around a hundred micrometers. The model describes the cyclic collapse and growth of a vapor bubble around the fuel droplet and its fragmentation. The main features of the model are: - the destabilization of the film or the vapor bubble due to the growth of Rayleigh-Taylor instabilities (those form coolant jets that contact the fuel surface); - The mechanisms of fragmentation, following the contacts (in the case of entrapment of a certain amount of coolant in the fuel, the entrapped coolant evaporates violently after it has been heated to the homogeneous nucleation temperature); - the transient heat transfer from the fragments to the coolant and the elevated vapor production, which leads to an important expansion of the bubble (about this point, the cooling of the fragments has been described by a transient heat transfer coefficient linked to nucleate boiling). The results of the model show good agreement with experimental data. (Author)

  7. Lambda-dropping

    DEFF Research Database (Denmark)

    Danvy, Olivier; Schultz, Ulrik Pagh

    1997-01-01

    Lambda-lifting a functional program transforms it into a set of recursive equations. We present the symmetric transformation: lambda-dropping. Lambda-dropping a set of recursive equations restores block structure and lexical scope.For lack of scope, recursive equations must carry around all...... the parameters that any of their callees might possibly need. Both lambda-lifting and lambda-dropping thus require one to compute a transitive closure over the call graph:• for lambda-lifting: to establish the Def/Use path of each free variable (these free variables are then added as parameters to each...... of the functions in the call path);• for lambda-dropping: to establish the Def/Use path of each parameter (parameters whose use occurs in the same scope as their definition do not need to be passed along in the call path).Without free variables, a program is scope-insensitive. Its blocks are then free...

  8. Vapor pressure and enthalpy of vaporization of aliphatic propanediamines

    International Nuclear Information System (INIS)

    Verevkin, Sergey P.; Chernyak, Yury

    2012-01-01

    Highlights: ► We measured vapor pressure of four aliphatic 1,3-diamines. ► Vaporization enthalpies at 298 K were derived. ► We examined consistency of new and available data in the literature. ► A group-contribution method for prediction was developed. - Abstract: Vapor pressures of four aliphatic propanediamines including N-methyl-1,3-propanediamine (MPDA), N,N-dimethyl-1,3-propanediamine (DMPDA), N,N-diethyl-1,3-propanediamine (DEPDA) and N,N,N′,N′-tetramethyl-1,3-propanediamine (4MPDA) were measured using the transpiration method. The vapor pressures developed in this work and reported in the literature were used to derive molar enthalpy of vaporization values at the reference temperature 298.15 K. An internal consistency check of the enthalpy of vaporization was performed for the aliphatic propanediamines studied in this work. A group-contribution method was developed for the validation and prediction vaporization enthalpies of amines and diamines.

  9. An autopsy study of death due to Suicidal Hanging – 264 cases

    Directory of Open Access Journals (Sweden)

    Dinesh Rao

    2016-09-01

    Full Text Available The present study was carried out between 2010 and 2013, a total of 7968 Autopsies were conducted of which 3.31% (n – 264 cases were deaths due to hanging. The most preferred ligature materials were Stole (n – 79 and Bed spread/Sari (n – 68. In 88% of the cases, hanging was complete. Females (n – 136 and males (n – 128 were equally affected. The major age group involved in both the sexes was of 31–40 years, contributing to 50.76% (n – 136 of the self suspension. In 80.58% (n – 213 of the incidents, ligature mark showed discontinuity (incomplete. A Slip type of knot was used in majority of the noose, contributing to 97.73% (n – 258 of the suspensions. In 87.88% (n – 232 of hanging an oblique shaped ligature mark was noticed. The horizontal and near oblique ligature marks were seen only in cases of partial suspension. In 95.45% (n – 252 of the cases, the ligature mark showed blackening of the skin (friction burn. Only 4.54% (n – 12 showed intact skin. The outer layer of the skin over the ligature mark showed displacement in majority of the cases. Married victims contributed to 70.45% of cases. Domestic issues were the commonest reason (n – 82 for self suspension, of which female (n – 68 formed the majority of victims. In 70.83% (n – 187 of cases damage to neck muscle fibers and hemorrhage at the Sternal end of the Sternocleidomastoid muscle were present. In 85.61% (n – 226 of cases the cervical vertebra was intact. In 52.27% (n – 138 of the cases the internal carotid artery showed transverse tear. In 99.42% (n – 248 cases the thyroid cartilage was found intact. The hyoid bone was damaged in 6.06% (n – 16 of the victims. Majority of the victims, 59.09% (n – 156 belonged to low socioeconomic class.

  10. Two-phase heat transfer and pressure drop of LNG during saturated flow boiling in a horizontal tube

    Science.gov (United States)

    Chen, Dongsheng; Shi, Yumei

    2013-12-01

    Two-phase heat transfer and pressure drop of LNG (liquefied natural gas) have been measured in a horizontal smooth tube with an inner diameter of 8 mm. The experiments were conducted at inlet pressures from 0.3 to 0.7 MPa with a heat flux of 8-36 kW m-2, and mass flux of 49.2-201.8 kg m-2 s-1. The effect of vapor quality, inlet pressure, heat flux and mass flux on the heat transfer characteristic are discussed. The comparisons of the experimental data with the predicted value by existing correlations are analyzed. Zou et al. (2010) correlation shows the best accuracy with 24.1% RMS deviation among them. Moreover four frictional pressure drop methods are also chosen to compare with the experimental database.

  11. Vapor pressure and enthalpy of vaporization of linear aliphatic alkanediamines

    International Nuclear Information System (INIS)

    Pozdeev, Vasiliy A.; Verevkin, Sergey P.

    2011-01-01

    Highlights: → We measured vapor pressure of diamines H 2 N-(CH 2 ) n -NH 2 with n = 3 to 12. → Vaporization enthalpies at 298 K were derived. → We examined consistency of new and available in the literature data. → Enthalpies of vaporization show linear dependence on numbers n. → Enthalpies of vaporization correlate linearly with Kovat's indices. - Abstract: Vapor pressures and the molar enthalpies of vaporization of the linear aliphatic alkanediamines H 2 N-(CH 2 ) n -NH 2 with n = (3 to 12) have been determined using the transpiration method. A linear correlation of enthalpies of vaporization (at T = 298.15 K) of the alkanediamines with the number n and with the Kovat's indices has been found, proving the internal consistency of the measured data.

  12. DEEP HANGING WALL TRAPS-THE REMAINING PROMISSING TARGETS FOR OIL EXPLORATION IN THE NIGER DELTA

    International Nuclear Information System (INIS)

    Oton, S.W

    2004-01-01

    It is well known that the most dominant types of Hydrocarbon types found in the petroliferous Niger Delta are the classical rollover anticlinical traps 'I of oil exploration in the delta, these easy-to-find rollover structures are getting exhausted. They are most numerous at shallow depths in the younger delta front sedimentary sequence. Generally, during this primary oil exploration stage, oil and gas exploration have been concentrated in the shallow depths where they are easy to reach, easy to explore and easy to produce. This means that the present and future exploration campaigns in the Niger Delta should be directed towards other types of hydrocarbon trapping mechanisms that have been mapped in the delta. Many exploration models have been used and oil has been found in at least nine types of traps in the Niger Delta. The contrary (or anitithetic) fault model was used at the close of the last century. This model is so called because the controlling antithetic fault has a regional dip contrary to the structure-building growth fault with which it is associated. These faults, which are widespread in the Niger Delta, are easy to map especially on the Petro geological model. In this period, several promising hydrocarbon accumulations trapped against antithetic faults were discovered and tested. These hydrocarbon targets also seem fully explored and exhausted now. Recently, from modern high resolution 2-D and 3-D seismic data a lot of good prospects have been mapped and drilled in the deep horizon. In the last few years, a lot of unexplored oil have been discovered and tested in the deep horizons. They are mostly in hanging wall traps, at depth below 4,000 meters. This shows that most of the remaining undiscovered hydrocarbons in the Niger Delta may well be in these deep hanging wall traps between 4,000 and close to 5,600 meters. A definite search for deep-seated hanging wall traps is therefore recommended in a bid to find more new reservoirs and thereby increase the

  13. Measurement of the mass of an object hanging from a spring—revisited

    International Nuclear Information System (INIS)

    Serafin, Kamil; Oracz, Joanna; Grzybowski, Marcin; Koperski, Maciej; Sznajder, Paweł; Zinkiewicz, Łukasz; Wasylczyk, Piotr

    2012-01-01

    In an open competition, students were to determine the mass of a metal cylinder hanging on a spring inside a transparent enclosure. With the time for experiments limited to 24 h due to the unexpectedly large number of participants, a few surprisingly accurate results were submitted, the best of them differing by no more than 0.5% from the true value with a relative uncertainty of less than 1%.

  14. Controlling charge on levitating drops.

    Science.gov (United States)

    Hilger, Ryan T; Westphall, Michael S; Smith, Lloyd M

    2007-08-01

    Levitation technologies are used in containerless processing of materials, as microscale manipulators and reactors, and in the study of single drops and particles. Presented here is a method for controlling the amount and polarity of charge on a levitating drop. The method uses single-axis acoustic levitation to trap and levitate a single, initially neutral drop with a diameter between 400 microm and 2 mm. This drop is then charged in a controllable manner using discrete packets of charge in the form of charged drops produced by a piezoelectric drop-on-demand dispenser equipped with a charging electrode. The magnitude of the charge on the dispensed drops can be adjusted by varying the voltage applied to the charging electrode. The polarity of the charge on the added drops can be changed allowing removal of charge from the trapped drop (by neutralization) and polarity reversal. The maximum amount of added charge is limited by repulsion of like charges between the drops in the trap. This charging scheme can aid in micromanipulation and the study of charged drops and particles using levitation.

  15. On-line mass spectrometry system for measurements at single-crystal electrodes in hanging meniscus configuration

    NARCIS (Netherlands)

    Wonders, A.H.; Housmans, T.H.M.; Rosca, V.; Koper, M.T.M.

    2006-01-01

    We present the construction and some first applications of an On-line electrochemical mass spectrometry system for detecting volatile products formed during electrochemical reactions at a single-crystal electrode in hanging meniscus configuration. The system is based on a small inlet tip made of

  16. SU-F-T-75: Dosimetry Considerations in the Use of Hanging-Eye Block for Lesions of the Conjunctiva

    Energy Technology Data Exchange (ETDEWEB)

    Grelewicz, Z; Lee, B; Cutright, D; Kang, Z; Gopalakrishnan, M; Sathiaseelan, V; Zhang, H [Northwestern Memorial Hospital, Chicago, IL (United States)

    2016-06-15

    Purpose: Superficial lesions in the conjunctiva are frequently treated with en face electrons, using a hanging block to spare dose to the lens of the eye. Dose to the tumor and lens depend on the design and setup of the block and supporting apparatus. We performed in phantom measurements in order to characterize the dose sparing effects of the block as well as the under-dosing effect under the supporting apparatus for 6 MeV treatment. Methods: The commercial hanging block studied uses a 1.2 cm diameter tungsten cylinder supported by a 3 mm diameter acrylic rod. Point dose measurements under the hanging block, under an unblocked part of the field, and under the acrylic rod were performed using MOSFET detectors. In addition, EBT3 film was used for both PDD and profile measurements at a depth in phantom of 3 mm for both 105 and 103 cm SSD. Results: MOSFET measurements reported a dose reduction of 95% under the tungsten block when using an SSD of 103 cm, and 86% when using an SSD of 105 cm at a depth in phantom of 3 mm. Film measurements showed that the area under the acrylic rod may be under-dosed by as much as 30% when using 103 SSD. MOSFET measurements confirmed that when using an SSD of 103 cm, the area under the acrylic rod is under-dosed by up to 30% at 3mm depth, compared to the unblocked part of the field. Conclusion: The effectiveness of the commercial hanging block apparatus depends on setup, with 95% lens sparing possible with an SSD of 103 cm. This short SSD is necessary for sharp penumbra. At this SSD, substantial under-dosing under the acrylic support rod is possible. This must be mitigated with either feathering, or using an alternative method of support for the tungsten block.

  17. Extending total parenteral nutrition hang time in the neonatal intensive care unit: is it safe and cost effective?

    Science.gov (United States)

    Balegar V, Kiran Kumar; Azeem, Mohammad Irfan; Spence, Kaye; Badawi, Nadia

    2013-01-01

    To investigate the effects of prolonging hang time of total parenteral nutrition (TPN) fluid on central line-associated blood stream infection (CLABSI), TPN-related cost and nursing workload. A before-after observational study comparing the practice of hanging TPN bags for 48 h (6 February 2009-5 February 2010) versus 24 h (6 February 2008-5 February 2009) in a tertiary neonatal intensive care unit was conducted. The main outcome measures were CLABSI, TPN-related expenses and nursing workload. One hundred thirty-six infants received 24-h TPN bags and 124 received 48-h TPN bags. Median (inter-quartile range) gestation (37 weeks (33,39) vs. 36 weeks (33,39)), mean (±standard deviation) admission weight of 2442 g (±101) versus 2476 g (±104) and TPN duration (9.7 days (±12.7) vs. 9.9 days (±13.4)) were similar (P > 0.05) between the 24- and 48-h TPN groups. There was no increase in CLABSI with longer hang time (0.8 vs. 0.4 per 1000 line days in the 24-h vs. 48-h group; P < 0.05). Annual cost saving using 48-h TPN was AUD 97,603.00. By using 48-h TPN, 68.3% of nurses indicated that their workload decreased and 80.5% indicated that time spent changing TPN reduced. Extending TPN hang time from 24 to 48 h did not alter CLABSI rate and was associated with a reduced TPN-related cost and perceived nursing workload. Larger randomised controlled trials are needed to more clearly delineate these effects. © 2012 The Authors. Journal of Paediatrics and Child Health © 2012 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  18. Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single-Family Homes

    Energy Technology Data Exchange (ETDEWEB)

    Cummings, James [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Withers, Charles [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Martin, Eric [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States); Moyer, Neil [Building America Partnership for Improved Residential Construction (BA-PIRC), Cocoa, FL (United States)

    2012-10-01

    This report is a revision of an earlier report titled: Measure Guideline: Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single-Family Homes. Revisions include: Information in the text box on page 1 was revised to reflect the most accurate information regarding classifications as referenced in the 2012 International Residential Code. “Measure Guideline” was dropped from the title of the report. An addition was made to the reference list.

  19. Dynamics of deforming drops

    OpenAIRE

    Bouwhuis, W.

    2015-01-01

    Liquid drops play a dominant role in numerous industrial applications, such as spray coating, spray painting, inkjet printing, lithography processes, and spraying/sprinkling in agriculture or gardening. In all of these examples, the generation, flight, impact, and spreading of drops are separate stages of the corresponding industrial processes, which are all thoroughly studied for many years. This thesis focuses on drop dynamics, impact phenomena, Leidenfrost drops, and pouring flows. Based o...

  20. Scanning drop sensor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian; Xiang, Chengxiang; Gregoire, John

    2017-05-09

    Electrochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  1. Formation and evolution of mesozoic volcanic basins in Gan-Hang tectonic belt

    International Nuclear Information System (INIS)

    Zhang Xingpu

    1999-01-01

    The author mainly discusses the principle model for the formation and the evolution of Mesozoic volcanic basins in the Gan-Hang Tectonic Belt, and describes the distinct evolution features between the internal and external sites of volcanic basins, the natural relation between the down-warped, down-faulted, collapse volcanic basins and volcanic domes, the relationship between the formation of inter layered fractured zones of the volcanic cover and the evolution of volcanic basins

  2. VAPOR PRESSURES AND HEATS OF VAPORIZATION OF PRIMARY COAL TARS

    Energy Technology Data Exchange (ETDEWEB)

    Eric M. Suuberg; Vahur Oja

    1997-07-01

    This project had as its main focus the determination of vapor pressures of coal pyrolysis tars. It involved performing measurements of these vapor pressures and from them, developing vapor pressure correlations suitable for use in advanced pyrolysis models (those models which explicitly account for mass transport limitations). This report is divided into five main chapters. Each chapter is a relatively stand-alone section. Chapter A reviews the general nature of coal tars and gives a summary of existing vapor pressure correlations for coal tars and model compounds. Chapter B summarizes the main experimental approaches for coal tar preparation and characterization which have been used throughout the project. Chapter C is concerned with the selection of the model compounds for coal pyrolysis tars and reviews the data available to us on the vapor pressures of high boiling point aromatic compounds. This chapter also deals with the question of identifying factors that govern the vapor pressures of coal tar model materials and their mixtures. Chapter D covers the vapor pressures and heats of vaporization of primary cellulose tars. Chapter E discusses the results of the main focus of this study. In summary, this work provides improved understanding of the volatility of coal and cellulose pyrolysis tars. It has resulted in new experimentally verified vapor pressure correlations for use in pyrolysis models. Further research on this topic should aim at developing general vapor pressure correlations for all coal tars, based on their molecular weight together with certain specific chemical characteristics i.e. hydroxyl group content.

  3. The detection of organic solvent vapor by using polymer coated chemocapacitor sensor

    Science.gov (United States)

    Rusdiarna Indrapraja, Apik; Rivai, Muhammad; Arifin, Achmad; Purwanto, Djoko

    2017-05-01

    A chemocapacitor consists of planar interdigital electrodes (IDE) made by two comb electrodes on a substrate. A dielectric film was applied on the electrodes in which the absorbed vapor will modify its permittivity. This study has fabricated chemocapacitor with the IDE distance of 0.5 mm, while the dielectric film was a sensitive layer consisting of a polymeric material. The deposition of the polymeric film was accomplished by drop casting. A sensor array consisting of four chemocapacitors coated with different polymers namely PEG-1540, PEG-20M, PEG-6000, and PVP was used to obtain the pattern of shift in the capacitance. The integrated circuit AD7746 was used as the capacitance to-digital converter (CDC). The organic solvents of ethanol, benzene, and aceton were used as the vapor samples in this experiment. The results showed that the change in the capacitance value increases proportionally to the concentration of vapour where sensors coated with PEG-1540 and PVP have higher sensitivity, i.e. 0.0028pF/part per thousand and 0.0027pF/part per thousand, respectively. Based on the capacitance to digital conversion capabilities, the system provides there solution of 0.4084ppm. The sensor array could produce a different pattern for each of the vapor sample. The Neural Network pattern recognition system could identify the type of vapor automatically with the root mean square error of 10-5

  4. Detrended cross-correlation analysis on RMB exchange rate and Hang Seng China Enterprises Index

    Science.gov (United States)

    Ruan, Qingsong; Yang, Bingchan; Ma, Guofeng

    2017-02-01

    In this paper, we investigate the cross-correlations between the Hang Seng China Enterprises Index and RMB exchange markets on the basis of a cross-correlation statistic test and multifractal detrended cross-correlation analysis (MF-DCCA). MF-DCCA has, at best, serious limitations for most of the signals describing complex natural processes and often indicates multifractal cross-correlations when there are none. In order to prevent these false multifractal cross-correlations, we apply MFCCA to verify the cross-correlations. Qualitatively, we find that the return series of the Hang Seng China Enterprises Index and RMB exchange markets were, overall, significantly cross-correlated based on the statistical analysis. Quantitatively, we find that the cross-correlations between the stock index and RMB exchange markets were strongly multifractal, and the multifractal degree of the onshore RMB exchange markets was somewhat larger than the offshore RMB exchange markets. Moreover, we use the absolute return series to investigate and confirm the fact of multifractality. The results from the rolling windows show that the short-term cross-correlations between volatility series remain high.

  5. Scanning drop sensor

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Jian; Xiang, Chengxiang; Gregoire, John M.; Shinde, Aniketa A.; Guevarra, Dan W.; Jones, Ryan J.; Marcin, Martin R.; Mitrovic, Slobodan

    2017-05-09

    Electrochemical or electrochemical and photochemical experiments are performed on a collection of samples by suspending a drop of electrolyte solution between an electrochemical experiment probe and one of the samples that serves as a test sample. During the electrochemical experiment, the electrolyte solution is added to the drop and an output solution is removed from the drop. The probe and collection of samples can be moved relative to one another so the probe can be scanned across the samples.

  6. Flutter instability of freely hanging articulated pipes conveying fluid

    Science.gov (United States)

    Schouveiler, Lionel; Chermette, Félix

    2018-03-01

    We experimentally investigate the stability of freely hanging articulated pipes made of rigid segments connected by flexible joints and with their displacements constrained in a vertical plane. When the velocity of the fluid conveyed by the pipe is increased, flutter-type instability occurs above a critical value. The critical velocity and the characteristics of the flutter modes (frequency, amplitude, and shape) are determined as a function of the number n of segments into the pipe which is varied from 2 to 5. Experimental results are compared to predictions from linear stability analysis extending previous studies by taking into account damping due to the dissipation in the joints. Qualitative agreement is found and the limits of the analysis are discussed.

  7. Overexpression, purification, crystallization and preliminary X-ray studies of Vibrio cholerae EpsG

    International Nuclear Information System (INIS)

    Jens, Jason; Raghunathan, Kannan; Vago, Frank; Arvidson, Dennis

    2009-01-01

    Recombinant V. cholerae EpsG has been expressed, purified and crystallized. The crystals diffracted to 2.26 Å resolution. EpsG is the major pseudopilin protein of the Vibrio cholerae type II secretion system. An expression plasmid that encodes an N-terminally truncated form of EpsG with a C-terminal noncleavable His tag was constructed. Recombinant EpsG was expressed in Escherichia coli; the truncated protein was purified and crystallized by hanging-drop vapor diffusion against a reservoir containing 6 mM zinc sulfate, 60 mM MES pH 6.5, 15% PEG MME 550. The crystals diffracted X-rays to a resolution of 2.26 Å and belonged to space group P2 1 , with unit-cell parameters a = 88.61, b = 70.02, c = 131.54 Å

  8. Crystallization and preliminary X-ray diffraction analysis of red clover necrotic mosaic virus

    International Nuclear Information System (INIS)

    Martin, Stanton L.; Guenther, Richard H.; Sit, Tim L.; Swartz, Paul D.; Meilleur, Flora; Lommel, Steven A.; Rose, Robert B.

    2010-01-01

    Virions of red clover necrotic mosaic virus have been purified and crystallized. The space group was determined to be I23, with unit-cell parameter a = 377.8 Å. The crystals diffracted to 4 Å resolution. Red clover necrotic mosaic virus (RCNMV) is a species that belongs to the Tombusviridae family of plant viruses with a T = 3 icosahedral capsid. RCNMV virions were purified and were crystallized for X-ray analysis using the hanging-drop vapor-diffusion method. Self-rotation functions and systematic absences identified the space group as I23, with two virions in the unit cell. The crystals diffracted to better than 4 Å resolution but were very radiation-sensitive, causing rapid decay of the high-resolution reflections. The data were processed to 6 Å in the analysis presented here

  9. Hanging out at the airport: Unusual upside-down perching behavior by Eurasian Jackdaws (Corvus monedula) in a human-dominated environment

    Science.gov (United States)

    Katzner, Todd E.

    2016-01-01

    Animals occupying human-dominated environments show the capacity for behavioral flexibility. Corvids are among the most intelligent synanthropic bird species. During a layover at Schipol Airport in Amsterdam, Netherlands, I photographically documented Eurasian Jackdaws (Corvus monedula) perching upside down from a building cornice. In contrast to other reports of hanging birds, these jackdaws did not forage or play while upside down and appeared to use the perching spot to observe their surroundings. Although Corvids and Psittacines are known to hang upside down, especially in captive situations, such behaviors are rarely documented in the wild, and never before in association with human-built structures.

  10. Global lower mesospheric water vapor revealed by LIMS observations

    Science.gov (United States)

    Gordley, L. L.; Russell, J. M., III; Remsberg, E. E.

    1985-01-01

    The Limb Infrared Monitor of the Stratospheric water vapor channel data analysis has been extended from the 1. mb level (about 48 km) to the .3 mb level (about 60 km) through a radiance averaging procedure and better understanding of systematic errors. The data show H2O mixing ratio peaks near the .5 mb level varying from 4 to 7 ppmv with latitude and season. Above this level the mixing ratio drops off quickly with altitude, but, due to experimental uncertainties, at an uncertain rate. The stratospheric results are virtually the same as determined from the archived LIMS results with a tropical hygropause and enhanced H2O concentration in the lower levels at high winter latitudes.

  11. Enthalpy of Vaporization and Vapor Pressures: An Inexpensive Apparatus

    Science.gov (United States)

    Battino, Rubin; Dolson, David A.; Hall, Michael A.; Letcher, Trevor M.

    2007-01-01

    A simple and inexpensive method to determine the enthalpy of vaporization of liquids by measuring vapor pressure as a function of temperature is described. The vapor pressures measured with the stopcock cell were higher than the literature values and those measured with the sidearm rubber septum cell were both higher and lower than literature…

  12. Understanding evaporation characteristics of a drop of distilled sulfur mustard (HD) chemical agent from stainless steel and aluminum substrates

    Energy Technology Data Exchange (ETDEWEB)

    Jung, H., E-mail: junghs@add.re.kr; Lee, H.W.

    2014-05-01

    Highlights: • Evaporation rates of HD are obtained from stainless steel and aluminum substrates. • The rates increase with temperature and are linearly proportional to drop size. • HD evaporation from stainless steel follows only constant contact area mechanism. • HD evaporation from aluminum proceeds by a combined mechanism. - Abstract: We report herein the evaporation rates and mechanism of a drop of distilled sulfur mustard (HD) agent from stainless steel and aluminum substrates. For systematic analysis, we used a laboratory-sized wind tunnel, thermal desorption (TD) connected to gas chromatograph/mass spectrometry (GC/MS) and drop shape analysis (DSA). We found that the evaporation rates of HD from stainless steel and aluminum increased with temperature. The rates were also linearly proportional to drop size. The time-dependent contact angle measurement showed that the evaporation of the drop of HD proceeded only by constant contact area mechanism from stainless steel surface. On the other hand, the evaporation of HD from aluminum proceeded by a combined mechanism of constant contact area mode and constant contact angle mode. Our experimental data sets and analysis could be used to predict vapor and contact hazard persistence of chemical warfare agents (CWAs) in the air and on exterior surfaces with chemical releases, which assists the military decision influencing personnel safety and decontamination of the site upon a chemical attack event.

  13. Understanding evaporation characteristics of a drop of distilled sulfur mustard (HD) chemical agent from stainless steel and aluminum substrates

    International Nuclear Information System (INIS)

    Jung, H.; Lee, H.W.

    2014-01-01

    Highlights: • Evaporation rates of HD are obtained from stainless steel and aluminum substrates. • The rates increase with temperature and are linearly proportional to drop size. • HD evaporation from stainless steel follows only constant contact area mechanism. • HD evaporation from aluminum proceeds by a combined mechanism. - Abstract: We report herein the evaporation rates and mechanism of a drop of distilled sulfur mustard (HD) agent from stainless steel and aluminum substrates. For systematic analysis, we used a laboratory-sized wind tunnel, thermal desorption (TD) connected to gas chromatograph/mass spectrometry (GC/MS) and drop shape analysis (DSA). We found that the evaporation rates of HD from stainless steel and aluminum increased with temperature. The rates were also linearly proportional to drop size. The time-dependent contact angle measurement showed that the evaporation of the drop of HD proceeded only by constant contact area mechanism from stainless steel surface. On the other hand, the evaporation of HD from aluminum proceeded by a combined mechanism of constant contact area mode and constant contact angle mode. Our experimental data sets and analysis could be used to predict vapor and contact hazard persistence of chemical warfare agents (CWAs) in the air and on exterior surfaces with chemical releases, which assists the military decision influencing personnel safety and decontamination of the site upon a chemical attack event

  14. An acoustical bubble counter for superheated drop detectors

    International Nuclear Information System (INIS)

    Taylor, C.; Montvila, D.; Flynn, D.; Brennan, C.; D'Errico, F.

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons. (authors)

  15. An acoustical bubble counter for superheated drop detectors.

    Science.gov (United States)

    Taylor, Chris; Montvila, Darius; Flynn, David; Brennan, Christopher; d'Errico, Francesco

    2006-01-01

    A new bubble counter has been developed based on the well-established approach of detecting vaporization events acoustically in superheated drop detectors (SDDs). This counter is called the Framework Scientific ABC 1260, and it represents a major improvement over prior versions of this technology. By utilizing advanced acoustic pattern recognition software, the bubble formation event can be differentiated from ambient background noise, as well as from other acoustic signatures. Additional structural design enhancements include a relocation of the electronic components to the bottom of the device; thus allowing for greater stability, easier access to vial SDDs without exposure to system electronics. Upgrades in the electronics permit an increase in the speed of bubble detection by almost 50%, compared with earlier versions of the counters. By positioning the vial on top of the device, temperature and sound insulation can be accommodated for extreme environments. Lead shells can also be utilized for an enhanced response to high-energy neutrons.

  16. Vapor pressures and vaporization enthalpy of codlemone by correlation gas chromatography

    International Nuclear Information System (INIS)

    Schultz, Shannon M.; Harris, Harold H.; Chickos, James S.

    2015-01-01

    Highlights: • The vaporization enthalpy of codlemone has been evaluated. • The vapor pressure of codlemone has been evaluated from T = (298.15 to T b ) K. • Vapor pressures for the 1-alkanols standards are available from T = (298.15 to 500) K. - Abstract: The vapor pressure and vaporization enthalpy of codlemone (trans, trans 8,10-dodecadien-1-ol), the female sex hormone of the codling moth is evaluated by correlation gas chromatography using a series of saturated primary alcohols as standards. A vaporization enthalpy of (92.3 ± 2.6) kJ · mol −1 and a vapor pressure, p/Pa = (0.083 ± 0.012) were evaluated at T = 298.15 K. An equation for the evaluation of vapor pressure from ambient temperature to boiling has been derived by correlation for codlemone. The calculated boiling temperature of T B = 389 K at p = 267 Pa is within the temperature range reported in the literature. A normal boiling temperature of T B = (549.1 ± 0.1) K is also estimated by extrapolation

  17. 29 CFR 1926.907 - Use of safety fuse.

    Science.gov (United States)

    2010-07-01

    ... way shall be forbidden. (b) The hanging of a fuse on nails or other projections which will cause a...-called “drop fuse” method of dropping or pushing a primer or any explosive with a lighted fuse attached...

  18. Flash vaporization during earthquakes evidenced by gold deposits

    Science.gov (United States)

    Weatherley, Dion K.; Henley, Richard W.

    2013-04-01

    Much of the world's known gold has been derived from arrays of quartz veins. The veins formed during periods of mountain building that occurred as long as 3 billion years ago, and were deposited by very large volumes of water that flowed along deep, seismically active faults. The veins formed under fluctuating pressures during earthquakes, but the magnitude of the pressure fluctuations and their influence on mineral deposition is not known. Here we use a simple thermo-mechanical piston model to calculate the drop in fluid pressure experienced by a fluid-filled fault cavity during an earthquake. The geometry of the model is constrained using measurements of typical fault jogs, such as those preserved in the Revenge gold deposit in Western Australia, and other gold deposits around the world. We find that cavity expansion generates extreme reductions in pressure that cause the fluid that is trapped in the jog to expand to a very low-density vapour. Such flash vaporization of the fluid results in the rapid co-deposition of silica with a range of trace elements to form gold-enriched quartz veins. Flash vaporization continues as more fluid flows towards the newly expanded cavity, until the pressure in the cavity eventually recovers to ambient conditions. Multiple earthquakes progressively build economic-grade gold deposits.

  19. Petroleum Vapor Intrusion

    Science.gov (United States)

    One type of vapor intrusion is PVI, in which vapors from petroleum hydrocarbons such as gasoline, diesel, or jet fuel enter a building. Intrusion of contaminant vapors into indoor spaces is of concern.

  20. Millisecond-period meltdown experiments on prompt-burst effects and molten-tin-water dropping experiments

    International Nuclear Information System (INIS)

    Wright, R.W.; Coats, R.L.; Schmidt, T.R.; Arakeri, V.H.

    1976-01-01

    The U.S. Nuclear Regulatory Commission has initiated a program of confirmatory research for the safety assessment of LMFBR plants. In the sodium-fuel interactions area, this research includes a series of real-time in-pile experiments on the pressure and work potential of prompt-burst excursions as well as laboratory dropping experiments with molten tin and water. The in-pile experiments are performed by Sandia Laboratories in the Annular Core Pulse Reactor (ACPR), which has a minimum period of 1.3 milliseconds. These single-pin experiments are performed in a piston-loaded, stagnent-sodium autoclave, that is conceptually similar to the one used in the S-11 TREAT test. Unlike the S-11 test, however, realistic radial temperature profiles are obtained in the fuel, the cladding, and the sodium by pre-pulsing the reactor about 1/2 second before the main pulse. A series of preparatory runs have been made with helium-filled capsules and at low energy with sodium-filled capsules. The first significant fuel-coolant interaction run is scheduled for late March 1976. This will be a double-pulsed run at 2700 j/gm UO 2 . A continuing series of experiments is planned with oxide and advanced fuels in both fresh and irradiated form. In molten-tin-water dropping experiments at UCLA, microsecond duration multi-flash photography has been used for event diagnostics. Transition or nucleate boiling was found to trigger energetic interactions or vapor explosions. Temperature stratification in the water was found to reduce the threshold tin temperature necessary to produce vapor explosions below that the predicted by the coolant homogeneous nucleation hypothesis. Interaction zone growth times of a few msec. were measured. (auth.)

  1. Millisecond-Period Meltdown Experiments on Prompt - Burst Effects and Molten-Tin-Water Dropping Experiments

    International Nuclear Information System (INIS)

    Wright, R.W.; Coats, R.L.; Schmidt, T.R.; Arakeri, V.H.

    1976-01-01

    The U.S. Nuclear Regulatory Commission has initiated a program of confirmatory research for the safety assessment of LMFBR plants. In the sodium-fuel interactions area, this research includes a series of real-time in-pile experiments on the pressure and work potential of prompt-burst excursions as well as laboratory dropping experiments with molten tin and water. The in-pile experiments are performed by Sandia Laboratories in the Annular Core Pulse Reactor (ACPR), which has a minimum period of 1.3 milliseconds. These single-pin experiments are performed in a piston-loaded, stagnant-sodium autoclave, that is conceptually similar to the one used in the S-11 TREAT test. Unlike the S-11 test, however, realistic radial temperature profiles are obtained in the fuel, the cladding, and the sodium by pre-pulsing the reactor about 1/2 second before the main pulse. A series of preparatory runs have been made with helium-filled capsules and at low energy with sodium-filled capsules. The first significant fuel-coolant interaction run is scheduled for late March 1976. This will be a double-pulsed run at 2700 j/gm UO 2 . A continuing series of experiments is planned with oxide and advanced fuels in both fresh and irradiated form. In molten-tin-water dropping experiments at UCLA, microsecond duration multi-flash photography has been used for event diagnostics. Transition or nucleate boiling was found to trigger energetic interactions or vapor explosions. Temperature stratification in the water was found to reduce the threshold tin temperature necessary to produce vapor explosions below that the predicted by the coolant homogeneous nucleation hypothesis. Interaction zone growth times of a few msec were measured

  2. 29 CFR Appendix B to Subpart I of... - General Testing Conditions and Additional Guidelines for Personal Fall Protection Systems (Non...

    Science.gov (United States)

    2010-07-01

    ..., to its hanging location (6 feet (1.83 m) below the anchorage). The test weight should fall without... belts, the complete belt should withstand a drop test consisting of a 250 pound (113.4 kg) weight.... One belt terminal should be attached to a rigid anchor and the other terminal should hang free. The...

  3. Rehabilitation approaches to dysphagia that was developed for a patient who attempted to commit suicide by hanging: a case report.

    Science.gov (United States)

    Kii, Y; Mizuma, M

    2014-04-01

    We report our experience with a case of attempted suicidal hanging presenting with dysphagia, in which rehabilitation approaches resulted in improvement. A 36-year-old man was discovered collapsed at home. From the finding of a broken cord nearby, attempted suicide by hanging was suspected. He was transported to hospital after 40 minutes, and regained consciousness after emergency treatment. There were no noteworthy findings on brain magnetic resonance imaging, cervical spine computed tomography, or vocal cord examination. There were no noteworthy psychiatric disorders or cognitive abnormalities. On hospital day 10, he showed signs of dysphagia. Videofluoroscopic examination of swallowing revealed piriform sinuses residue and aspiration after ingestion of jelly in any posture. Rehabilitation approaches were started based on the diagnosis of dysphagia due to impaired transit through the piriform sinuses. The patient achieved independent oral intake by 40 days after the injury. In this case, dysphagia was considered attributable to compression of the vagus nerves running along the lateral aspects of the neck by the cord used in the hanging. If compression is brief, full functional recovery can be expected. Implementation of rehabilitation approaches is also important in this situation.

  4. Operation characteristic of a heat pump of mechanical vapor recompression propelled by fans and its performance analysis applied to waste-water treatment

    Science.gov (United States)

    Weike, Pang; Wenju, Lin; Qilin, Pan; Wenye, Lin; Qunte, Dai; Luwei, Yang; Zhentao, Zhang

    2014-01-01

    In this paper, a set of heat pump (called as Mechanical Vapor Recompression, MVR) propelled by a centrifugal fan is tested and it shows some special characteristic when it works together with a falling film evaporator. Firstly, an analysis of the fan's suction and discharge parameters at stable state, such as its pressure and temperature, indicates that a phenomenon of wet compression is probably to appear during vapor compression. As a result, superheat after saturated vapor is compressed is eliminated, which reduces discharge temperature of the system. It is because drops boil away and absorb the super heat into their latent heat during vapor compression. Meanwhile, drops in the suction vapor add to the compressed vapor, which increase the given heat of the MVR heat pump. Next, assistant electric heat could adjust and keep steady of the operating pressure and temperature of an MVR heat pump. With the evaporation temperature up to be high, heat balance is broken and supplement heat needs to increase. Thirdly, the performance of an MVR heat pump is affect by the balance of falling film and evaporation that has an effect on heat transfer. Then, two parameters standing for the performance are measured as it runs in practical condition. The two important parameters are consumptive electricity power and productive water capacity. According to theoretical work in ideal condition by calculation and fan's input power by measure as running, adiabatic efficiency (ηad) of a centrifugal fan is calculated when it is applied in a heat pump of MVR. Following, based on ηad, practical SMER and COP of an MVR heat pump are discovered to be correlative with it. Finally, in dependence on productive water in theory and in practice, displacement efficiency (ηv) of centrifugal fans is obtained when compressing vapor, and so provide some references of matching a fan for an MVR heat pump. On the other hand, it is helpful to research and develop MVR heat pumps, and also to check

  5. Liver hanging maneuver for right hemiliver in situ donation – anatomical considerations

    OpenAIRE

    Trotovšek, B.; Gadžijev, E.M.; Ravnik, D.; Hribernik, M.

    2006-01-01

    Background. An anatomical study was carried out to evaluate the safety of the liver hanging maneuver for the right hemiliver in living donor and in situ splitting transplantation. During this procedure a 4–6 cm blind dissection is performed between the inferior vena cava and the liver. Short subhepatic veins entering the inferior vena cava from segments 1 and 9 could be torn with consequent hemorrhage. Materials and methods. One hundred corrosive casts of livers were evaluated to establish th...

  6. Toxicologic Laboratory Findings in Cases Reported with Hanging Death: a Two-Year Retrospective Study in Northeast Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Ranjbar

    2013-09-01

    How to cite this article: Ranjbar R, Liaghat AR, Ranjbar A, Mohabbati H. Toxicologic Laboratory Findings in Cases Reported with Hanging Death: a Two-Year Retrospective Study in Northeast Iran. Asia Pac J Med Toxicol 2013;2:92-5.

  7. Continuous and simultaneous measurements of precipitation and vapor isotopes over two monsoon seasons during 2016-2017 in Singapore

    Science.gov (United States)

    Jackisch, D.; He, S.; Ong, M. R.; Goodkin, N.

    2017-12-01

    Water isotopes are important tracers of climate dynamics and their measurement can provide valuable insights into the relationship between isotopes and atmospheric parameters and overall convective activities. While most studies provide data on daily or even monthly time scales, high-temporal in-situ stable isotope measurements are scarce, especially in the tropics. In this study, we presented δ18O and δ2H values in precipitation and vapor continuously and simultaneously measured using laser spectroscopy in Singapore during the 2016/2017 Northeast (NE) Asian monsoon and 2017 Southwest (SW) Asian monsoon. We found that δ-values of precipitation and vapor exhibit quite different patterns during individual events, although there is a significant correlation between the δ-values of precipitation and of vapor. δ-values in precipitation during individual precipitation events show a distinct V-shape pattern, with the lowest isotope values observed in the middle of the event. However, isotopes in water vapor mostly show an L-shape and are characterized by a gradual decrease with the onset of rainfall. The difference in δ-values of precipitation and vapor is generally constant during the early stage of the events but gradually increases near the end. It is likely that vapor and precipitation are closer to equilibrium at the early stage of a rain event, but diverge at the later stages. This divergence can be largely attributed to the evaporation of raindrops. We notice a frequent drop in d-excess of precipitation, whereas d-excess in vapor increases. In addition, a significant correlation exists between outgoing longwave radiation (OLR) and isotopes in both precipitation and vapor, suggesting an influence of regional convective activity.

  8. Contact angle of sessile drops in Lennard-Jones systems.

    Science.gov (United States)

    Becker, Stefan; Urbassek, Herbert M; Horsch, Martin; Hasse, Hans

    2014-11-18

    Molecular dynamics simulations are used for studying the contact angle of nanoscale sessile drops on a planar solid wall in a system interacting via the truncated and shifted Lennard-Jones potential. The entire range between total wetting and dewetting is investigated by varying the solid-fluid dispersive interaction energy. The temperature is varied between the triple point and the critical temperature. A correlation is obtained for the contact angle in dependence of the temperature and the dispersive interaction energy. Size effects are studied by varying the number of fluid particles at otherwise constant conditions, using up to 150,000 particles. For particle numbers below 10,000, a decrease of the contact angle is found. This is attributed to a dependence of the solid-liquid surface tension on the droplet size. A convergence to a constant contact angle is observed for larger system sizes. The influence of the wall model is studied by varying the density of the wall. The effective solid-fluid dispersive interaction energy at a contact angle of θ = 90° is found to be independent of temperature and to decrease linearly with the solid density. A correlation is developed that describes the contact angle as a function of the dispersive interaction, the temperature, and the solid density. The density profile of the sessile drop and the surrounding vapor phase is described by a correlation combining a sigmoidal function and an oscillation term.

  9. Animations, games, and virtual reality for the Jing-Hang Grand Canal.

    Science.gov (United States)

    Chen, Wenzhi; Zhang, Mingmin; Pan, Zhigeng; Liu, Gengdai; Shen, Huaqing; Chen, Shengnan; Liu, Yong

    2010-01-01

    Digital heritage, an effective method to preserve and present natural and cultural heritage, is engaging many heritage preservation specialists and computer scientists. In particular, computer graphics researchers have become involved, and digital heritage has employed many CG techniques. For example, Daniel Pletinckx and his colleagues employed VR in a real museum at Ename, Belgium, and Zhigeng Pan and his colleagues applied it to construct a virtual Olympics museum. Soo-Chang Pei and his colleagues focused on restoring ancient Chinese paintings. Here, we describe how we've applied animations, computer games, and VR to China's famous Jing-Hang Grand Canal.

  10. Point of net vapor generation and vapor void fraction in subcooled boiling

    International Nuclear Information System (INIS)

    Saha, P.; Zuber, N.

    1974-01-01

    An analysis is presented directed at predicting the point of net vapor generation and vapor void fraction in subcooled boiling. It is shown that the point of net vapor generation depends upon local conditions--thermal and fluid dynamic. Thus, at low mass flow rates the net vapor generation is determined by thermal conditions, whereas at high mass flow rates the phenomenon is hydrodynamically controlled. Simple criteria are derived which can be used to predict these local conditions for net vapor generation. These criteria are used to determine the vapor void fraction is subcooled boiling. Comparison between the results predicted by this analysis and experimental data presently available shows good agreement for wide range of operating conditions, fluids and geometries. (U.S.)

  11. Vibration-Induced Climbing of Drops

    Science.gov (United States)

    Brunet, P.; Eggers, J.; Deegan, R. D.

    2007-10-01

    We report an experimental study of liquid drops moving against gravity, when placed on a vertically vibrating inclined plate, which is partially wetted by the drop. The frequency of vibrations ranges from 30 to 200 Hz, and, above a threshold in vibration acceleration, drops experience an upward motion. We attribute this surprising motion to the deformations of the drop, as a consequence of an up or down symmetry breaking induced by the presence of the substrate. We relate the direction of motion to contact angle measurements. This phenomenon can be used to move a drop along an arbitrary path in a plane, without special surface treatments or localized forcing.

  12. Effect of Different Catalyst Deposition Technique on Aligned Multiwalled Carbon Nanotubes Grown by Thermal Chemical Vapor Deposition

    Directory of Open Access Journals (Sweden)

    Mohamed Shuaib Mohamed Saheed

    2014-01-01

    Full Text Available The paper reported the investigation of the substrate preparation technique involving deposition of iron catalyst by electron beam evaporation and ferrocene vaporization in order to produce vertically aligned multiwalled carbon nanotubes array needed for fabrication of tailored devices. Prior to the growth at 700°C in ethylene, silicon dioxide coated silicon substrate was prepared by depositing alumina followed by iron using two different methods as described earlier. Characterization analysis revealed that aligned multiwalled carbon nanotubes array of 107.9 µm thickness grown by thermal chemical vapor deposition technique can only be achieved for the sample with iron deposited using ferrocene vaporization. The thick layer of partially oxidized iron film can prevent the deactivation of catalyst and thus is able to sustain the growth. It also increases the rate of permeation of the hydrocarbon gas into the catalyst particles and prevents agglomeration at the growth temperature. Combination of alumina-iron layer provides an efficient growth of high density multiwalled carbon nanotubes array with the steady growth rate of 3.6 µm per minute for the first 12 minutes and dropped by half after 40 minutes. Thicker and uniform iron catalyst film obtained from ferrocene vaporization is attributed to the multidirectional deposition of particles in the gaseous form.

  13. The vapor pressure and enthalpy of vaporization of M-xylene

    International Nuclear Information System (INIS)

    Rothenberg, S.J.; Seiler, F.A.; Bechtold, W.E.; Eidson, A.F.

    1988-01-01

    We measured the vapor pressure of m-xylene over the temperature range 273 to 293 deg K with a single-sided capacitance manometer. The enthalpy of vaporization was 42.2 ± 0.1 (SE) kj/ g·mol. Combining our own data with previously published data, we recommend using the values 42.0, 40.6, and 39.1 (± 0.1) (SE) kjg·mol for the enthalpy of vaporization of m-xylene at 300, 340, and 380 deg. K, respectively, and a value for the change in heat capacity on vaporization (ΔCpdeg.) of 35 ± 3 (SE) J/g·mol·K over the temperature range studied. (author)

  14. Drop Tower Physics

    Science.gov (United States)

    Dittrich, William A.

    2014-01-01

    The drop towers of yesteryear were used to make lead shot for muskets, as described in "The Physics Teacher" in April 2012. However, modern drop towers are essentially elevators designed so that the cable can "break" on demand, creating an environment with microgravity for a short period of time, currently up to nine seconds at…

  15. Modelling of the processes of heat and mass transfer in adiabatic steam and drop flows

    International Nuclear Information System (INIS)

    Andrizhievskij, A.A.; Mikhalevich, A.A.; Nesterenko, V.B.; Trifonov, A.G.

    1983-01-01

    The mathematical models for investigating the local and integral characteristics of heat and mass transfer processes during simultaneous motion of adiabatic steam and drop flow and a flux of impurity particles are given. The mathematical model is constrUcted on the basis of one-dimensional stationary eqUations of conservation of mass, thermal energy and momentum of liquid and vapor phases. Dispersion composition of condensed moisture is described by the Nukiyama-Tanasava distribution function formed taking into account the Veber number critical value. Equations of motion and mass balance conservation for impurity particles are included into the mathematical model. These equations are considered as additional inactive phase

  16. Ingestion of safety razor blade and delayed hanging in a complex suicide.

    Science.gov (United States)

    Chauhan, Mohit Singh; Behera, C; Naagar, Sunil; Sreenivas, M

    2016-12-01

    Ingestion of a foreign body is mostly accidental in children and intentional in prisoners to achieve hospitalization; however, use of this method of suicide is rare. We report a case where the victim first ingested a safety razor blade, but failed to die and then hanged himself, but failed again and finally succumbed to the complications on the sixth day. He had also attempted suicide by inflicting multiple incised wounds on his neck four days before the safety blade ingestion, but none were fatal. © The Author(s) 2016.

  17. Crystallization and preliminary X-ray diffraction analysis of salutaridine reductase from the opium poppy Papaver somniferum

    International Nuclear Information System (INIS)

    Higashi, Yasuhiro; Smith, Thomas J.; Jez, Joseph M.; Kutchan, Toni M.

    2010-01-01

    Recombinant P. somniferum salutaridine reductase (SalR) was purified and crystallized with NADPH using the hanging-drop vapor-diffusion method. Crystals of the SalR–NADPH complex diffracted X-rays to a resolution of 1.9 Å. The opium poppy Papaver somniferum is the source of the narcotic analgesics morphine and codeine. Salutaridine reductase (SalR; EC 1.1.1.248) reduces the C-7 keto group of salutaridine to the C-7 (S)-hydroxyl group of salutaridinol in the biosynthetic pathway that leads to morphine in the opium poppy plant. P. somniferum SalR was overproduced in Escherichia coli and purified using cobalt-affinity and size-exclusion chromatography. Hexagonal crystals belonging to space group P6 4 22 or P6 2 22 were obtained using ammonium sulfate as precipitant and diffracted to a resolution of 1.9 Å

  18. Drop "impact" on an airfoil surface.

    Science.gov (United States)

    Wu, Zhenlong

    2018-05-17

    Drop impact on an airfoil surface takes place in drop-laden two-phase flow conditions such as rain and icing, which are encountered by wind turbines or airplanes. This phenomenon is characterized by complex nonlinear interactions that manifest rich flow physics and pose unique modeling challenges. In this article, the state of the art of the research about drop impact on airfoil surface in the natural drop-laden two-phase flow environment is presented. The potential flow physics, hazards, characteristic parameters, droplet trajectory calculation, drop impact dynamics and effects are discussed. The most key points in establishing the governing equations for a drop-laden flow lie in the modeling of raindrop splash and water film. The various factors affecting the drop impact dynamics and the effects of drop impact on airfoil aerodynamic performance are summarized. Finally, the principle challenges and future research directions in the field as well as some promising measures to deal with the adverse effects of drop-laden flows on airfoil performance are proposed. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The vapor pressure and enthalpy of vaporization of M-xylene

    Energy Technology Data Exchange (ETDEWEB)

    Rothenberg, S J; Seiler, F A; Bechtold, W E; Eidson, A F

    1988-12-01

    We measured the vapor pressure of m-xylene over the temperature range 273 to 293 deg K with a single-sided capacitance manometer. The enthalpy of vaporization was 42.2 {+-} 0.1 (SE) kj/ g{center_dot}mol. Combining our own data with previously published data, we recommend using the values 42.0, 40.6, and 39.1 ({+-} 0.1) (SE) kjg{center_dot}mol for the enthalpy of vaporization of m-xylene at 300, 340, and 380 deg. K, respectively, and a value for the change in heat capacity on vaporization ({delta}Cpdeg.) of 35 {+-} 3 (SE) J/g{center_dot}mol{center_dot}K over the temperature range studied. (author)

  20. Effects of fullerol on the osteogenic differentiation of adipose-derived mesenchymal stem cells

    Directory of Open Access Journals (Sweden)

    Yan-ting TANG

    2016-09-01

    Full Text Available Objective  To investigate the effect of fullerol on the osteogenic differentiation of rat adipose-derived mesenchymal stem cells (rADSCs based on hanging drop culture. Methods  rADSC spheres were formed by hanging drop culture for 3 days, then the spheres were dissociated to single cell by trypsin (called rADSC sphere-derived cells. The rADSC sphere-derived cells were cultured in 2-D adherent cell cultures for 24 hours, then the ordinary culture medium was replaced by osteogenic induction medium (osteogenic medium, OM. OM without fullerol served as control group (CM; OM with 1.0μmol/L fullerol was used as the experimental group (OM+Ful1.0μmol/L. Two groups were induced to differentiation for 14d and 21d, using two methods of alizarin red staining and quantitative real-time PCR (qPCR to detecte the ability of rADSC sphere-derived cells differentiating into osteoblasts. Results  rADSCs could form a uniform size microspheres structure through hanging drop culture for 3 days; rADSC sphere-derived cells were obtained by dissipation of trypsin. Compared with OM group, OM+Ful1.0μmol/L can make rADSC sphere-derived cells form more mineralized calcium nodules, and enhance the expression of the relevant osteogenic gene Runx2, OCN and ColI. Conclusion  Fullerol can significantly enhance the osteogenic differentiation of rADSCs based on hanging drop culture, and it is helpful to improve the efficiency of osteogenic induction of rADSCs. DOI: 10.11855/j.issn.0577-7402.2016.08.03

  1. Experimental verification of a condenser with liquid–vapor separation in an air conditioning system

    International Nuclear Information System (INIS)

    Chen, Xueqing; Chen, Ying; Deng, Lisheng; Mo, Songping; Zhang, Haiyan

    2013-01-01

    Three liquid–vapor separation condensers (LSC) were tested to evaluate their ability to automatically separate the liquid and vapor during condensation. Each was used in a split-type air conditioner to investigate the performance. The performance of the LSC system having the greatest cooling capacity and energy efficiency ratio (EER) was then compared with that of the system having a baseline fin-and-tube condenser for various ambient temperatures from 29 °C to 43 °C. The results showed that both the cooling capacity and EER of the two systems were almost the same at the three standard conditions in the Chinese standard GB/T 7725-2004, with the LSC having just 67% of the heat transfer area of the baseline condenser. In addition, the LSC system was charged with only 80% of the refrigerant in the baseline system. -- Highlights: ► We tested three liquid–vapor separation condensers in an air conditioning system. ► The best system had the most uniform wall temperature and the smallest pressure drop. ► The LSC system performance with only 67% condenser area was as good as the baseline system. ► LSC system operations are compared for various outdoor temperatures

  2. Vortex flow in acoustically levitated drops

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Z.L.; Xie, W.J. [Department of Applied Physics, Northwestern Polytechnical University, Xi' an 710072 (China); Wei, B., E-mail: bbwei@nwpu.edu.cn [Department of Applied Physics, Northwestern Polytechnical University, Xi' an 710072 (China)

    2011-08-29

    The internal flow of acoustically levitated water drops is investigated experimentally. This study reveals a kind of vortex flow which rotates in the meridional plane of the levitated drop. The magnitude of fluid velocity is nearly vanishing at the drop center, whereas it increases toward the free surface of a levitated drop until the maximum value of about 80 mm/s. A transition of streamline shapes from concentric circles to ellipses takes place at the distance of about 1.2 mm from the drop center. The fluid velocity distribution is plotted as a function of polar angle for seven characteristic streamlines. -- Highlights: → We experimentally observe the internal flow of acoustically levitated water drops. → We present a fascinating structure of vortex flow inside the levitated water drop. → This vortex flow rotates around the drop center in the meridional plane. → Velocity distribution information of this vortex flow is quantitatively analyzed.

  3. Vortex flow in acoustically levitated drops

    International Nuclear Information System (INIS)

    Yan, Z.L.; Xie, W.J.; Wei, B.

    2011-01-01

    The internal flow of acoustically levitated water drops is investigated experimentally. This study reveals a kind of vortex flow which rotates in the meridional plane of the levitated drop. The magnitude of fluid velocity is nearly vanishing at the drop center, whereas it increases toward the free surface of a levitated drop until the maximum value of about 80 mm/s. A transition of streamline shapes from concentric circles to ellipses takes place at the distance of about 1.2 mm from the drop center. The fluid velocity distribution is plotted as a function of polar angle for seven characteristic streamlines. -- Highlights: → We experimentally observe the internal flow of acoustically levitated water drops. → We present a fascinating structure of vortex flow inside the levitated water drop. → This vortex flow rotates around the drop center in the meridional plane. → Velocity distribution information of this vortex flow is quantitatively analyzed.

  4. Crystallization, data collection and data processing of maltose-binding protein (MalE) from the phytopathogen Xanthomonas axonopodis pv. citri

    International Nuclear Information System (INIS)

    Souza, C. S.; Ferreira, L. C. S.; Thomas, L.; Barbosa, J. A. R. G.; Balan, A.

    2009-01-01

    The Xanthomonas axonopodis pv. citri maltose-binding protein MalE has been crystallized at 293 K using the hanging-drop vapour-diffusion method. Maltose-binding protein is the periplasmic component of the ABC transporter responsible for the uptake of maltose/maltodextrins. The Xanthomonas axonopodis pv. citri maltose-binding protein MalE has been crystallized at 293 K using the hanging-drop vapour-diffusion method. The crystal belonged to the primitive hexagonal space group P6 1 22, with unit-cell parameters a = 123.59, b = 123.59, c = 304.20 Å, and contained two molecules in the asymetric unit. It diffracted to 2.24 Å resolution

  5. Coalescence collision of liquid drops I: Off-center collisions of equal-size drops

    Directory of Open Access Journals (Sweden)

    Alejandro Acevedo-Malavé

    2011-09-01

    Full Text Available The Smoothed Particle Hydrodynamics method (SPH is used here to model off-center collisions of equal-size liquid drops in a three-dimensional space. In this study the Weber number is calculated for several conditions of the droplets dynamics and the velocity vector fields formed inside the drops during the collision process are shown. For the permanent coalescence the evolution of the kinetic and internal energy is shown and also the approaching to equilibrium of the resulting drop. Depending of the Weber number three possible outcomes for the collision of droplets is obtained: permanent coalescence, flocculation and fragmentation. The fragmentation phenomena are modeled and the formation of small satellite drops can be seen. The ligament that is formed follows the “end pinching” mechanism and it is transformed into a flat structure.

  6. Sensitive determination of mercury by a miniaturized spectrophotometer after in situ single-drop microextraction

    International Nuclear Information System (INIS)

    Yang Fangwen; Liu Rui; Tan Zhiqiang; Wen Xiaodong; Zheng Chengbin; Lv Yi

    2010-01-01

    An in situ single-drop microextraction (SDME) method was developed for trace mercury determination by a miniaturized spectrophotometer, in which a simple and cheap light-emitting diode (LED) was employed as the light source, and a handheld charge coupled device (CCD) was served as the detector. A droplet of 0.006% dithizone-CCl 4 (m/v) was used as extraction phase and hanged on a rolled PTFE tube. LED light was adjusted carefully to pass through the centre of the droplet and the entrance slit of the CCD detector. The radiation intensities of 475 nm before and after SDME (I 0 and I i ) were recorded for quantification. Under the optimum conditions, the system provided a linear range of 2-50 μg L -1 , with a correlation coefficient of 0.9983 and a limit of detection (3σ) of 0.2 μg L -1 . The enrichment factor was about 69. The present method showed the merits of high sensitivity, simplicity, rapidity, low reagent consumption and field analysis potential. Finally, this method was successfully applied for the determination of the total mercury in spiked tap water sample, spiked river water sample and certified reference material (GBW (E) 080393, simulated water).

  7. Sensitive determination of mercury by a miniaturized spectrophotometer after in situ single-drop microextraction.

    Science.gov (United States)

    Yang, Fangwen; Liu, Rui; Tan, Zhiqiang; Wen, Xiaodong; Zheng, Chengbin; Lv, Yi

    2010-11-15

    An in situ single-drop microextraction (SDME) method was developed for trace mercury determination by a miniaturized spectrophotometer, in which a simple and cheap light-emitting diode (LED) was employed as the light source, and a handheld charge coupled device (CCD) was served as the detector. A droplet of 0.006% dithizone-CCl(4) (m/v) was used as extraction phase and hanged on a rolled PTFE tube. LED light was adjusted carefully to pass through the centre of the droplet and the entrance slit of the CCD detector. The radiation intensities of 475 nm before and after SDME (I(0) and I(i)) were recorded for quantification. Under the optimum conditions, the system provided a linear range of 2-50 μg L(-1), with a correlation coefficient of 0.9983 and a limit of detection (3σ) of 0.2 μg L(-1). The enrichment factor was about 69. The present method showed the merits of high sensitivity, simplicity, rapidity, low reagent consumption and field analysis potential. Finally, this method was successfully applied for the determination of the total mercury in spiked tap water sample, spiked river water sample and certified reference material (GBW (E) 080393, simulated water). Copyright © 2010 Elsevier B.V. All rights reserved.

  8. "Self-Shaping" of Multicomponent Drops.

    Science.gov (United States)

    Cholakova, Diana; Valkova, Zhulieta; Tcholakova, Slavka; Denkov, Nikolai; Smoukov, Stoyan K

    2017-06-13

    In our recent study we showed that single-component emulsion drops, stabilized by proper surfactants, can spontaneously break symmetry and transform into various polygonal shapes during cooling [ Denkov Nature 2015 , 528 , 392 - 395 ]. This process involves the formation of a plastic rotator phase of self-assembled oil molecules beneath the drop surface. The plastic phase spontaneously forms a frame of plastic rods at the oil drop perimeter which supports the polygonal shapes. However, most of the common substances used in industry appear as mixtures of molecules rather than pure substances. Here we present a systematic study of the ability of multicomponent emulsion drops to deform upon cooling. The observed trends can be summarized as follows: (1) The general drop-shape evolution for multicomponent drops during cooling is the same as with single-component drops; however, some additional shapes are observed. (2) Preservation of the particle shape upon freezing is possible for alkane mixtures with chain length difference Δn ≤ 4; for greater Δn, phase separation within the droplet is observed. (3) Multicomponent particles prepared from alkanes with Δn ≤ 4 plastify upon cooling due to the formation of a bulk rotator phase within the particles. (4) If a compound, which cannot induce self-shaping when pure, is mixed with a certain amount of a compound which induces self-shaping, then drops prepared from this mixture can also self-shape upon cooling. (5) Self-emulsification phenomena are also observed for multicomponent drops. In addition to the three recently reported mechanisms of self-emulsification [ Tcholakova Nat. Commun. 2017 , ( 8 ), 15012 ], a new (fourth) mechanism is observed upon freezing for alkane mixtures with Δn > 4. It involves disintegration of the particles due to a phase separation of alkanes upon freezing.

  9. Enthalpy of vaporization and vapor pressure of whiskey lactone and menthalactone by correlation gas chromatography

    International Nuclear Information System (INIS)

    Simmons, Daniel; Chickos, James

    2017-01-01

    Highlights: • The vapor pressure and vaporization enthalpies of cis and trans-whiskey lactone have been evaluated. • Enthalpies of vaporization and vapor pressures of (+)-isomintlactone and (−)-mintlactone were also evaluated. • The sublimation enthalpy and corresponding vapor pressure of (+) -isomintlactone at T = 298.15 K is estimated. - Abstract: Enthalpies of vaporization at T = 298.15 K of cis and trans-whiskey lactone have been evaluated by correlation gas chromatography to be (68.4 ± 1.7) kJ·mol −1 and (67.5 ± 1.7) kJ·mol −1 , respectively. The enthalpies of vaporization of isomintlactone and mintlactone also evaluated by correlation gas chromatography have been found to have vaporization enthalpies of (74.2 ± 1.8) kJ·mol −1 and (73.2 ± 1.8) kJ·mol −1 respectively. The vapor pressures for cis and trans-whiskey lactone at T = 298.15 K have been evaluated as (1.5 ± 0.09) Pa and (2.0 ± 0.1) Pa using vapor pressures of a series of lactones as standards. Vapor pressures for isomintlactone and mintlactone were evaluated as (0.26 ± 0.012) Pa and (0.33 ± 0.02) Pa, respectively. Fusion and sublimation enthalpies for (+)-isomintlactone as well as the vapor pressure of the solid have been estimated.

  10. Dynamics of deforming drops

    NARCIS (Netherlands)

    Bouwhuis, W.

    2015-01-01

    Liquid drops play a dominant role in numerous industrial applications, such as spray coating, spray painting, inkjet printing, lithography processes, and spraying/sprinkling in agriculture or gardening. In all of these examples, the generation, flight, impact, and spreading of drops are separate

  11. Experiences of marijuana-vaporizer users.

    Science.gov (United States)

    Malouff, John M; Rooke, Sally E; Copeland, Jan

    2014-01-01

    Using a marijuana vaporizer may have potential harm-reduction advantages on smoking marijuana, in that the user does not inhale smoke. Little research has been published on use of vaporizers. In the first study of individuals using a vaporizer on their own initiative, 96 adults anonymously answered questions about their experiences with a vaporizer and their use of marijuana with tobacco. Users identified 4 advantages to using a vaporizer over smoking marijuana: perceived health benefits, better taste, no smoke smell, and more effect from the same amount of marijuana. Users identified 2 disadvantages: inconvenience of setup and cleaning and the time it takes to get the device operating for each use. Only 2 individuals combined tobacco in the vaporizer mix, whereas 15 combined tobacco with marijuana when they smoked marijuana. Almost all participants intended to continue using a vaporizer. Vaporizers seem to have appeal to marijuana users, who perceive them as having harm-reduction and other benefits. Vaporizers are worthy of experimental research evaluating health-related effects of using them.

  12. Crystallization and preliminary X ray analysis of nucleoside diphosphate kinase 1 from T. cruzi

    International Nuclear Information System (INIS)

    Gomez Barroso, J.A.; Aguilar, C.F.; Miranda, M.R.; Pereira, C.A.

    2009-01-01

    Introduction: Trypanosoma cruzi is the etiologic agent of Chagas disease. The Nucleoside diphosphate kinases (NDPKs) are enzymes involved in energy management and nucleoside balance in the cell. T. cruzi TcNDPK1, a canonical isoform. The objective of this work is obtaining protein's crystals, diffract and process the data for tridimensional structure resolution. Materials and Methods: TcNDPK1 was expressed in E. coli as a fusion protein with Nterminal His-tag. TcNDPK1 was overexpressed and purified by FPLC. Crystallization was assayed by sitting drop and hanging drop vapor diffusion method. Crystals was frozen and diffracted on synchrotron x-ray radiation in Campinas (Brasil). The data set collected was reduced and merged using MOSFLM and SCALA programs. Results and Discussion: His-TcNDPK was overexpressed, purified and crystallized. The crystals are diffracted and collected the data to 3.5A. The crystals belong to the trigonal space group P3, with unit cell parameters a=127.94, b=127.84, c=275.49. Structure determination is under way. These results will provide relevant information that could be the first step in rational drug design for treating Chagas disease.(authors)

  13. Electrohydrodynamics of a viscous drop with inertia.

    Science.gov (United States)

    Nganguia, H; Young, Y-N; Layton, A T; Lai, M-C; Hu, W-F

    2016-05-01

    Most of the existing numerical and theoretical investigations on the electrohydrodynamics of a viscous drop have focused on the creeping Stokes flow regime, where nonlinear inertia effects are neglected. In this work we study the inertia effects on the electrodeformation of a viscous drop under a DC electric field using a novel second-order immersed interface method. The inertia effects are quantified by the Ohnesorge number Oh, and the electric field is characterized by an electric capillary number Ca_{E}. Below the critical Ca_{E}, small to moderate electric field strength gives rise to steady equilibrium drop shapes. We found that, at a fixed Ca_{E}, inertia effects induce larger deformation for an oblate drop than a prolate drop, consistent with previous results in the literature. Moreover, our simulations results indicate that inertia effects on the equilibrium drop deformation are dictated by the direction of normal electric stress on the drop interface: Larger drop deformation is found when the normal electric stress points outward, and smaller drop deformation is found otherwise. To our knowledge, such inertia effects on the equilibrium drop deformation has not been reported in the literature. Above the critical Ca_{E}, no steady equilibrium drop deformation can be found, and often the drop breaks up into a number of daughter droplets. In particular, our Navier-Stokes simulations show that, for the parameters we use, (1) daughter droplets are larger in the presence of inertia, (2) the drop deformation evolves more rapidly compared to creeping flow, and (3) complex distribution of electric stresses for drops with inertia effects. Our results suggest that normal electric pressure may be a useful tool in predicting drop pinch-off in oblate deformations.

  14. A Downflow Hanging Sponge (DHS) reactor for faecal coliform removal from an Upflow Anaerobic Sludge Bed (UASB) effluent

    NARCIS (Netherlands)

    Yaya Beas, R.E.; Kujawa-Roeleveld, K.; Lier, van J.B.; Zeeman, G.

    2015-01-01

    This research was conducted to study the faecal coliforms removal capacity of Downflow Hanging Sponge (DHS) reactors as a post-treatment for an Upflow Anaerobic Sludge Blanket (UASB) reactor. Three long-term continuous lab-scale DHS reactors i.e. a reactor with cube type sponges without

  15. Vaporization inside a mini microfin tube: experimental results and modeling

    Science.gov (United States)

    Diani, A.; Rossetto, L.

    2015-11-01

    This paper proposes a comparison among the common R134a and the extremely low GWP refrigerant R1234yf during vaporization inside a mini microfin tube. This microfin tube has an internal diameter of 2.4 mm, it has 40 fins, with a fin height of 0.12 mm. Due to the high heat transfer coefficients shown by this tube, this technology can lead to a refrigerant charge reduction. Tests were run in the Heat Transfer in Micro Geometries Lab of the Dipartimento di Ingegneria Industriale of the Università di Padova. Mass velocities range between 375 and 940 kg m-2 s-1, heat fluxes from 10 to 50 kW m-2, vapour qualities from 0.10 to 0.99, at a saturation temperature of 30°C. The comparison among the two fluids is proposed at the same operating conditions, in order to highlight the heat transfer and pressure drop differences among the two refrigerants. In addition, two correlations are proposed to estimate the heat transfer coefficient and frictional pressure drop during refrigerant flow boiling inside mini microfin tubes. These correlations well predict the experimental values, and thus they can be used as a useful tool to design evaporators based on these mini microfin tubes.

  16. Verkapselungseinreichtung und -verfahren zur Verkapselung einer Probe in einer Polymerkapsel

    OpenAIRE

    Zimmermann, Heiko; Neubauer, Julia

    2015-01-01

    Source: WO15010763A1 [EN] The invention relates to an encapsulating device (100), which is designed to encapsulate a sample (1, 2) in a polymer capsule, comprising a drop generator (10), which is designed to provide a drop (3) of a suspension, which drop contains the sample (1), and a cross-linking device (20), which is designed to polymerize the drop (3), wherein the drop generator (10) has a retaining device (11), which is designed to accommodate the drop (3) in a hanging state, and the cro...

  17. Turbulence, bubbles and drops

    NARCIS (Netherlands)

    van der Veen, Roeland

    2016-01-01

    In this thesis, several questions related to drop impact and Taylor-Couette turbulence are answered. The deformation of a drop just before impact can cause a bubble to be entrapped. For many applications, such as inkjet printing, it is crucial to control the size of this entrapped bubble. To study

  18. Waste Tank Vapor Project: Tank vapor database development

    International Nuclear Information System (INIS)

    Seesing, P.R.; Birn, M.B.; Manke, K.L.

    1994-09-01

    The objective of the Tank Vapor Database (TVD) Development task in FY 1994 was to create a database to store, retrieve, and analyze data collected from the vapor phase of Hanford waste tanks. The data needed to be accessible over the Hanford Local Area Network to users at both Westinghouse Hanford Company (WHC) and Pacific Northwest Laboratory (PNL). The data were restricted to results published in cleared reports from the laboratories analyzing vapor samples. Emphasis was placed on ease of access and flexibility of data formatting and reporting mechanisms. Because of time and budget constraints, a Rapid Application Development strategy was adopted by the database development team. An extensive data modeling exercise was conducted to determine the scope of information contained in the database. a A SUN Sparcstation 1000 was procured as the database file server. A multi-user relational database management system, Sybase reg-sign, was chosen to provide the basic data storage and retrieval capabilities. Two packages were chosen for the user interface to the database: DataPrism reg-sign and Business Objects trademark. A prototype database was constructed to provide the Waste Tank Vapor Project's Toxicology task with summarized and detailed information presented at Vapor Conference 4 by WHC, PNL, Oak Ridge National Laboratory, and Oregon Graduate Institute. The prototype was used to develop a list of reported compounds, and the range of values for compounds reported by the analytical laboratories using different sample containers and analysis methodologies. The prototype allowed a panel of toxicology experts to identify carcinogens and compounds whose concentrations were within the reach of regulatory limits. The database and user documentation was made available for general access in September 1994

  19. The vapor pressures of explosives

    Energy Technology Data Exchange (ETDEWEB)

    Ewing, Robert G.; Waltman, Melanie J.; Atkinson, David A.; Grate, Jay W.; Hotchkiss, Peter

    2013-01-05

    The vapor pressures of many explosive compounds are extremely low and thus determining accurate values proves difficult. Many researchers, using a variety of methods, have measured and reported the vapor pressures of explosives compounds at single temperatures, or as a function of temperature using vapor pressure equations. There are large variations in reported vapor pressures for many of these compounds, and some errors exist within individual papers. This article provides a review of explosive vapor pressures and describes the methods used to determine them. We have compiled primary vapor pressure relationships traceable to the original citations and include the temperature ranges for which they have been determined. Corrected values are reported as needed and described in the text. In addition, after critically examining the available data, we calculate and tabulate vapor pressures at 25 °C.

  20. Boiling characteristics of dilute polymer solutions and implications for the suppression of vapor explosions

    Energy Technology Data Exchange (ETDEWEB)

    Bang, K.H.; Kim, M.H. [Univ. of Science and Technology, Pohang (Korea, Republic of)

    1995-09-01

    Quenching experiments of hot solid spheres in dilute aqueous solutions of polyethylene oxide polymer have been conducted for the purpose of investigating the physical mechanisms of the suppression of vapor explosions in this polymer solutions. Two spheres of 22.2mm and 9.5mm-diameter were tested in the polymer solutions of various concentrations at 30{degrees}C. Minimum film boiling temperature ({Delta}T{sub MFB}) in this highly-subcooled liquid rapidly decreased from over 700{degrees}c for pure water to about 150{degrees}C as the polymer concentration was increased up to 300ppm for 22.2mm sphere, and it decreased to 350{degrees}C for 9.5mm sphere. This rapid reduction of minimum film boiling temperature in the PEO aqueous solutions can explain its ability of the suppression of spontaneous vapor explosions. The ability of suppression of vapor explosions by dilute polyethylene oxide solutions against an external trigger pressure was tested by dropping molten tin into the polymer solutions at 25{degrees}C. It was observed that in 50ppm solutions more mass fragmented than in pure water, but produced weaker explosion pressures. The explosion was completely suppressed in 300ppm solutions with the external trigger. The debris size distributions of fine fragments smaller than 0.7mm were shown almost identical regardless of the polymer concentrations.

  1. Purification and crystallization of Bacillus subtilis NrnA, a novel enzyme involved in nanoRNA degradation

    Energy Technology Data Exchange (ETDEWEB)

    Nelersa, Claudiu M.; Schmier, Brad J.; Malhotra, Arun (Miami-MED)

    2012-05-08

    The final step in RNA degradation is the hydrolysis of RNA fragments five nucleotides or less in length (nanoRNA) to mononucleotides. In Escherichia coli this step is carried out by oligoribonuclease (Orn), a DEDD-family exoribonuclease that is conserved throughout eukaryotes. However, many bacteria lack Orn homologs, and an unrelated DHH-family phosphoesterase, NrnA, has recently been identified as one of the enzymes responsible for nanoRNA degradation in Bacillus subtilis. To understand its mechanism of action, B. subtilis NrnA was purified and crystallized at room temperature using the hanging-drop vapor-diffusion method with PEG 4000, PEG 3350 or PEG MME 2000 as precipitant. The crystals belonged to the primitive monoclinic space group P2{sub 1}, with unit-cell parameters a = 50.62, b = 121.3, c = 123.4 {angstrom}, {alpha} = 90, {beta} = 91.31, {gamma} = 90{sup o}.

  2. Expression, purification, crystallization and preliminary crystallographic analysis of chitinase A from Vibrio carchariae

    International Nuclear Information System (INIS)

    Songsiriritthigul, Chomphunuch; Yuvaniyama, Jirundon; Robinson, Robert C.; Vongsuwan, Archara; Suginta, Wipa

    2005-10-01

    Chitinase A of Vibrio carchariae was functionally expressed in Escherichia coli M15 host cells as a C-terminally proteolytic processed fragment using the pQE60 expression vector. The yield of the 63-kDa protein was purified, yielding ∼70 mg per liter of bacterial culture. Crystals of recombinant chitinase A were obtained by the hanging-drop vapor diffusion method in a precipitant containing 10% (v/v) PEG 400, 0.1 M sodium acetate p H 4.6 and 0.125 M CaCl 2 . The crystals belonged to the tetragonal space group P422 with two molecules per asymmetric unit and unit-cell parameters a = b 127.64 Angstrom, and c = 171.42 Angstrom. A complete diffraction data set was collected to 2.14 Angstrom resolution, using a Rigaku/MSC R-AXIS IV ++ detector system mounted on an RU-H3R rotating-anode X-ray generator

  3. Building blocks for ionic liquids: Vapor pressures and vaporization enthalpies of 1-(n-alkyl)-imidazoles

    International Nuclear Information System (INIS)

    Emel'yanenko, Vladimir N.; Portnova, Svetlana V.; Verevkin, Sergey P.; Skrzypczak, Andrzej; Schubert, Thomas

    2011-01-01

    Highlights: → We measured vapor pressures of the 1-(n-alkyl)-imidazoles by transpiration method. → Variations on the alkyl chain length n were C 3 , C 5 -C 7 , and C 9 -C 10 . → Enthalpies of vaporization were derived from (p, T) dependencies. → Enthalpies of vaporization at 298.15 K were linear dependent on the chain length. - Abstract: Vapor pressures of the linear 1-(n-alkyl)-imidazoles with the alkyl chain C 3 , C 5 -C 7 , and C 9 -C 10 have been measured by the transpiration method. The molar enthalpies of vaporization Δ l g H m of these compounds were derived from the temperature dependencies of vapor pressures. A linear correlation of enthalpies of vaporization Δ l g H m (298.15 K) of the 1-(n-alkyl)-imidazoles with the chain length has been found.

  4. Dispersion of silver particles in aqueous solutions visualized by polarography/voltammetry

    Czech Academy of Sciences Publication Activity Database

    Korshunov, A.; Heyrovský, Michael

    2009-01-01

    Roč. 54, č. 26 (2009), s. 6264-6268 ISSN 0013-4686 R&D Projects: GA AV ČR IAA400400806 Institutional research plan: CEZ:AV0Z40400503 Keywords : silver ions * silver particles * drop ping mercury electrode * hanging mercury drop electrode Subject RIV: CG - Electrochemistry Impact factor: 3.325, year: 2009

  5. Drop impact splashing and air entrapment

    KAUST Repository

    Thoraval, Marie-Jean

    2013-03-01

    Drop impact is a canonical problem in fluid mechanics, with numerous applications in industrial as well as natural phenomena. The extremely simple initial configuration of the experiment can produce a very large variety of fast and complex dynamics. Scientific progress was made in parallel with major improvements in imaging and computational technologies. Most recently, high-speed imaging video cameras have opened the exploration of new phenomena occurring at the micro-second scale, and parallel computing allowed realistic direct numerical simulations of drop impacts. We combine these tools to bring a new understanding of two fundamental aspects of drop impacts: splashing and air entrapment. The early dynamics of a drop impacting on a liquid pool at high velocity produces an ejecta sheet, emerging horizontally in the neck between the drop and the pool. We show how the interaction of this thin liquid sheet with the air, the drop or the pool, can produce micro-droplets and bubble rings. Then we detail how the breakup of the air film stretched between the drop and the pool for lower impact velocities can produce a myriad of micro-bubbles.

  6. Vapor pressure and enthalpy of vaporization of oil of catnip by correlation gas chromatography

    International Nuclear Information System (INIS)

    Simmons, Daniel; Gobble, Chase; Chickos, James

    2016-01-01

    Highlights: • Vaporization enthalpies of the nepetalactones from oil of catnip have been evaluated. • Vapor pressures from T = (298.15 to 350) K have been evaluated. • Oil of catnip has a vapor pressure similar to DEET at T = 298.15 K. - Abstract: The vaporization enthalpy and vapor pressure of the two nepetalactones found in Nepeta cataria have been evaluated by correlation gas chromatography. Vaporization enthalpies at T = 298.15 K of {(68.0 ± 1.9) and (69.4 ± 1.9)} kJ ⋅ mol"−"1 have been derived for the minor diastereomer, (4aS,7S,7aS)-nepetalactone, and major one, (4aS,7S,7aR)-nepetalactone, respectively. Vapor pressures also at T = 298.15 K of p = (1.2 ± 0.04) Pa and (0.91 ± 0.03) Pa have been evaluated for the minor and the major stereoisomer. In addition to being of interest because of the remarkable effect it has on various felids, oil of catnip is also quite effective in repelling mosquitoes, comparable to diethyl-m-toluamide (DEET). The vapor pressures evaluated in this work suggest that the two stereoisomers have similar volatility to DEET at ambient temperatures.

  7. Obtaining of lysozyme spherulitic forms at ambient temperature using pyrrolidinium octanoat as ionic liquid additive

    Directory of Open Access Journals (Sweden)

    Claudia Simona ŞTEFAN

    2012-12-01

    Full Text Available Pyrrolidinium octanoate carboxylate (Py+CnH2n+1COO-; PyO in abbreviation was used as additive for advanced crystallization of Lysozyme protein, to investigate the impact of protic ionic liquid on the protein crystal morphology. The ionic liquid was synthesized by acidic-base Brönsted neutralization, and its purity was checked by HPLC. The protein crystallization was made through the method of vapour diffusion with hanging drops. Crystallization experiments of Lysozyme with the addition of PyO were performed at 0.4 M PyO and respectively 1.6 M. The morphological of spherulitic forms of Lysozyme in aqueous solutions of PyO protic ionic liquid was investigated by optical microscopy after trials were incubated at ambient temperature (18-20°C, in various growth periods (3 days and 1 week. Hanging-drop vapour diffusion crystallization experiments with the addition of 0.4 M of PyO show that Lysozyme crystallized in type I spherulitic form. This is assumed to be a result of heterogeneous nucleation, with thin needles radially growing outwardfrom a more or less spherical particle. Hanging-drop vapour diffusioncrystallization experiments revealed that the addition of 1.6 M of PyO led to a second type of spherulitic form of the Lysozyme.

  8. Insights from the pollination drop proteome and the ovule transcriptome of Cephalotaxus at the time of pollination drop production.

    Science.gov (United States)

    Pirone-Davies, Cary; Prior, Natalie; von Aderkas, Patrick; Smith, Derek; Hardie, Darryl; Friedman, William E; Mathews, Sarah

    2016-05-01

    Many gymnosperms produce an ovular secretion, the pollination drop, during reproduction. The drops serve as a landing site for pollen, but also contain a suite of ions and organic compounds, including proteins, that suggests diverse roles for the drop during pollination. Proteins in the drops of species of Chamaecyparis, Juniperus, Taxus, Pseudotsuga, Ephedra and Welwitschia are thought to function in the conversion of sugars, defence against pathogens, and pollen growth and development. To better understand gymnosperm pollination biology, the pollination drop proteomes of pollination drops from two species of Cephalotaxus have been characterized and an ovular transcriptome for C. sinensis has been assembled. Mass spectrometry was used to identify proteins in the pollination drops of Cephalotaxus sinensis and C. koreana RNA-sequencing (RNA-Seq) was employed to assemble a transcriptome and identify transcripts present in the ovules of C. sinensis at the time of pollination drop production. About 30 proteins were detected in the pollination drops of both species. Many of these have been detected in the drops of other gymnosperms and probably function in defence, polysaccharide metabolism and pollen tube growth. Other proteins appear to be unique to Cephalotaxus, and their putative functions include starch and callose degradation, among others. Together, the proteins appear either to have been secreted into the drop or to occur there due to breakdown of ovular cells during drop production. Ovular transcripts represent a wide range of gene ontology categories, and some may be involved in drop formation, ovule development and pollen-ovule interactions. The proteome of Cephalotaxus pollination drops shares a number of components with those of other conifers and gnetophytes, including proteins for defence such as chitinases and for carbohydrate modification such as β-galactosidase. Proteins likely to be of intracellular origin, however, form a larger component of drops

  9. Langevin modelling of high-frequency Hang-Seng index data

    Science.gov (United States)

    Tang, Lei-Han

    2003-06-01

    Accurate statistical characterization of financial time series, such as compound stock indices, foreign currency exchange rates, etc., is fundamental to investment risk management, pricing of derivative products and financial decision making. Traditionally, such data were analyzed and modeled from a purely statistics point of view, with little concern on the specifics of financial markets. Increasingly, however, attention has been paid to the underlying economic forces and the collective behavior of investors. Here we summarize a novel approach to the statistical modeling of a major stock index (the Hang Seng index). Based on mathematical results previously derived in the fluid turbulence literature, we show that a Langevin equation with a variable noise amplitude correctly reproduces the ubiquitous fat tails in the probability distribution of intra-day price moves. The form of the Langevin equation suggests that, despite the extremely complex nature of financial concerns and investment strategies at the individual's level, there exist simple universal rules governing the high-frequency price move in a stock market.

  10. CANFLEX fuel bundle junction pressure drop

    International Nuclear Information System (INIS)

    Chung, H. J.; Chung, C. H.; Jun, J. S.; Hong, S. D.; Chang, S. K.; Kim, B. D.

    1996-11-01

    This report describes the junction pressure drop test results which are to used to determine the alignment angle between bundles to achieve the most probable fuel string pressure drop for randomly aligned bundles for use in the fuel string total pressure drop test. (author). 4 tabs., 17 figs

  11. CANFLEX fuel bundle junction pressure drop

    Energy Technology Data Exchange (ETDEWEB)

    Chung, H. J.; Chung, C. H.; Jun, J. S.; Hong, S. D.; Chang, S. K.; Kim, B. D.

    1996-11-01

    This report describes the junction pressure drop test results which are to used to determine the alignment angle between bundles to achieve the most probable fuel string pressure drop for randomly aligned bundles for use in the fuel string total pressure drop test. (author). 4 tabs., 17 figs.

  12. 49 CFR 178.603 - Drop test.

    Science.gov (United States)

    2010-10-01

    ... used for the hydrostatic pressure or stacking test. Exceptions for the number of steel and aluminum..., non-resilient, flat and horizontal surface. (e) Drop height. Drop heights, measured as the vertical... than flat drops, the center of gravity of the test packaging must be vertically over the point of...

  13. Surgical results of the slipped medial rectus muscle after hang back recession surgery

    Directory of Open Access Journals (Sweden)

    Yasar Duranoglu

    2014-12-01

    Full Text Available AIM:To analyze the surgical results of a slipped medial rectus muscle (MRM after hang back recession surgery for esotropia.METHODS:Twenty-one patients who underwent re-exploration for diagnosed slipped muscle after hang back recession surgery were included in this retrospective study. Dynamic magnetic resonance imaging was performed to identify the location of the slipped muscle. Ocular motility was evaluated with assessment with prism and cover test in gaze at cardinal positions. The operations were performed by the same consultant. Intraoperative forced duction test was performed under general anesthesia. The empty sheath of the slipped MRM was resected and the muscle was advanced to the original insertion site in all patients.RESULTS:The average age of 21 patients who hadconsecutive exotropia with a slipped MRM at the time of presentation was 17.4±5.4y (5-50y. The average duration between the first operation and the diagnosis of the slipped muscle was 25mo (12 to 36mo. The mean follow up after the corrective surgery was 28mo. The mean preoperative adduction limitation in the field of action of the slipped muscle was -2.26 (ranging from -1 to -4. All patients had full adduction postoperatively.CONCLUSION:The diagnosis of the slipped muscle should be confirmed during the strabismus surgery. The slipped muscle may be caused due to insufficient suture and excessive rubbing of the eye. When divergent strabismus is observed after the recession of the MRM, a slipped muscle should be considered in the differential diagnosis.

  14. Comparative study of heat transfer and pressure drop during flow boiling and flow condensation in minichannels

    Directory of Open Access Journals (Sweden)

    Mikielewicz Dariusz

    2014-09-01

    Full Text Available In the paper a method developed earlier by authors is applied to calculations of pressure drop and heat transfer coefficient for flow boiling and also flow condensation for some recent data collected from literature for such fluids as R404a, R600a, R290, R32,R134a, R1234yf and other. The modification of interface shear stresses between flow boiling and flow condensation in annular flow structure are considered through incorporation of the so called blowing parameter. The shear stress between vapor phase and liquid phase is generally a function of nonisothermal effects. The mechanism of modification of shear stresses at the vapor-liquid interface has been presented in detail. In case of annular flow it contributes to thickening and thinning of the liquid film, which corresponds to condensation and boiling respectively. There is also a different influence of heat flux on the modification of shear stress in the bubbly flow structure, where it affects bubble nucleation. In that case the effect of applied heat flux is considered. As a result a modified form of the two-phase flow multiplier is obtained, in which the nonadiabatic effect is clearly pronounced.

  15. Vapor pressures and vaporization enthalpy of (−) α-bisabolol and (dl) menthol by correlation gas chromatography

    International Nuclear Information System (INIS)

    Keating, Leasa; Harris, Harold H.; Chickos, James S.

    2017-01-01

    Highlights: • The vaporization enthalpy and vapor pressure of (−) α-bisabolol and (dl)-menthol have been measured as a function of temperature. • Vapor pressures, vaporization enthalpies and boiling temperatures have been compared to available literature data. • Vapor pressures of (l)-menthol are compared to (dl)-menthol. - Abstract: The vapor pressures and vaporization enthalpies of (−) α-bisabolol and (dl)-menthol, two GRAS chemicals (generally recognized as safe) are evaluated by correlation gas chromatography using a series of saturated primary alcohols as standards. Vaporization enthalpies of (96.6 ± 2.4) and (74.2 ± 2.8) kJ mol −1 and vapor pressures of p/Pa = (0.020 ± 0.003) and (4.5 ± 0.44) were evaluated at T = 298.15 K for (−) α-bisabolol and (dl)-menthol, respectively, and compared to literature values. The vapor pressures of both compounds from T = (298.15 to 500) K have been derived from correlations using vapor pressures of a series of 1-alkanols and corresponding gas chromatographic retention times at 10 K intervals. The results were fit to a second order polynomial. Calculated normal boiling temperatures of T B = (574.8 and 492.7) K are calculated for (−) α-bisabolol and (dl)-menthol, respectively. A normal boiling temperature of T B = (485.2, and 489.7) K has previously been reported for (dl)-menthol. Vapor pressures for both (l)-menthol and (dl)-menthol from a previous study and (dl)-menthol from this study are compared with literature values.

  16. Liquid-gas mass transfer at drop structures

    DEFF Research Database (Denmark)

    Matias, Natércia; Nielsen, Asbjørn Haaning; Vollertsen, Jes

    2017-01-01

    -water mass transfer, little is known about hydrogen sulfide emission under highly turbulent conditions (e.g., drop structures, hydraulic jumps). In this study, experimental work was carried out to analyze the influence of characteristics of drops on reaeration. Physical models were built, mimicking typical...... sewer drop structures and allowing different types of drops, drop heights, tailwater depths and flow rates. In total, 125 tests were performed. Based on their results, empirical expressions translating the relationship between the mass transfer of oxygen and physical parameters of drop structures were...... established. Then, by applying the two-film theory with two-reference substances, the relation to hydrogen sulfide release was defined. The experiments confirmed that the choice of the type of drop structure is critical to determine the uptake/emission rates. By quantifying the air-water mass transfer rates...

  17. Melting temperature, vapor density, and vapor pressure of molybdenum pentafluoride

    Energy Technology Data Exchange (ETDEWEB)

    Krause, Jr, R F; Douglas, T B [National Bureau of Standards, Washington, D.C. (USA). Inst. for Materials Research

    1977-12-01

    A sample of MoF/sub 5/ was prepared by reaction of MoF/sub 6/(g) and Mo(c). Melting curves of temperature against time established the melting temperature at zero impurity to be 318.85 K, the enthalpy of fusion to be 6.1 kJ mol/sup -1/ (+ - 5 per cent), and the cryoscopic impurity of the sample to be 0.15 mole per cent. In the presence of MoF/sub 6/(g) which was added to suppress disproportionation, the vapor density of MoF/sub 5/ over the liquid was measured by the transpiration method at 343, 363, and 383 K, the total MoF/sub 5/ that evaporated being determined by permanganate titration. The total vapor pressure of MoF/sub 5/ oligomers over the liquid was measured by a simple static method at 373 and 392 K, while melting temperatures were taken alternately to monitor possible contamination of the sample. Although the vapor pressures were adjusted for disproportionation, solution of MoF/sub 6/ in MoF/sub 5/ (1), and wall adsorption of MoF/sub 6/ their percentage uncertainty is probably several times that of the vapor densities. A combination of the two properties indicates the average extent of association of the saturated vapor to be near 2, which is the value for the dimer species (MoF/sub 5/)/sub 2/.

  18. Nonlinear oscillations of inviscid free drops

    Science.gov (United States)

    Patzek, T. W.; Benner, R. E., Jr.; Basaran, O. A.; Scriven, L. E.

    1991-01-01

    The present analysis of free liquid drops' inviscid oscillations proceeds through solution of Bernoulli's equation to obtain the free surface shape and of Laplace's equation for the velocity potential field. Results thus obtained encompass drop-shape sequences, pressure distributions, particle paths, and the temporal evolution of kinetic and surface energies; accuracy is verified by the near-constant drop volume and total energy, as well as the diminutiveness of mass and momentum fluxes across drop surfaces. Further insight into the nature of oscillations is provided by Fourier power spectrum analyses of mode interactions and frequency shifts.

  19. The Drop Tower Bremen -Experiment Operation

    Science.gov (United States)

    Könemann, Thorben; von Kampen, Peter; Rath, Hans J.

    The idea behind the drop tower facility of the Center of Applied Space Technology and Micro-gravity (ZARM) in Bremen is to provide an inimitable technical opportunity of a daily access to short-term weightlessness on earth. In this way ZARM`s european unique ground-based microgravity laboratory displays an excellent economic alternative for research in space-related conditions at low costs comparable to orbital platforms. Many national and international ex-perimentalists motivated by these prospects decide to benefit from the high-quality and easy accessible microgravity environment only provided by the Drop Tower Bremen. Corresponding experiments in reduced gravity could open new perspectives of investigation methods and give scientists an impressive potential for a future technology and multidisciplinary applications on different research fields like Fundamental Physics, Astrophysics, Fluid Dynamics, Combus-tion, Material Science, Chemistry and Biology. Generally, realizing microgravity experiments at ZARM`s drop tower facility meet new requirements of the experimental hardware and may lead to some technical constraints in the setups. In any case the ZARM Drop Tower Operation and Service Company (ZARM FAB mbH) maintaining the drop tower facility is prepared to as-sist experimentalists by offering own air-conditioned laboratories, clean rooms, workshops and consulting engineers, as well as scientific personal. Furthermore, ZARM`s on-site apartment can be used for accommodations during the experiment campaigns. In terms of approaching drop tower experimenting, consulting of experimentalists is mandatory to successfully accomplish the pursued drop or catapult capsule experiment. For this purpose there will be a lot of expertise and help given by ZARM FAB mbH in strong cooperation to-gether with the experimentalists. However, in comparison to standard laboratory setups the drop or catapult capsule setup seems to be completely different at first view. While defining a

  20. Piezoelectric trace vapor calibrator

    International Nuclear Information System (INIS)

    Verkouteren, R. Michael; Gillen, Greg; Taylor, David W.

    2006-01-01

    The design and performance of a vapor generator for calibration and testing of trace chemical sensors are described. The device utilizes piezoelectric ink-jet nozzles to dispense and vaporize precisely known amounts of analyte solutions as monodisperse droplets onto a hot ceramic surface, where the generated vapors are mixed with air before exiting the device. Injected droplets are monitored by microscope with strobed illumination, and the reproducibility of droplet volumes is optimized by adjustment of piezoelectric wave form parameters. Complete vaporization of the droplets occurs only across a 10 deg. C window within the transition boiling regime of the solvent, and the minimum and maximum rates of trace analyte that may be injected and evaporated are determined by thermodynamic principles and empirical observations of droplet formation and stability. By varying solution concentrations, droplet injection rates, air flow, and the number of active nozzles, the system is designed to deliver--on demand--continuous vapor concentrations across more than six orders of magnitude (nominally 290 fg/l to 1.05 μg/l). Vapor pulses containing femtogram to microgram quantities of analyte may also be generated. Calibrated ranges of three explosive vapors at ng/l levels were generated by the device and directly measured by ion mobility spectrometry (IMS). These data demonstrate expected linear trends within the limited working range of the IMS detector and also exhibit subtle nonlinear behavior from the IMS measurement process

  1. Sodium vapor deposition onto a horizontal flat plate above liquid sodium surface, 2

    International Nuclear Information System (INIS)

    Kudo, Kazuhiko; Hirata, Masaru.

    1977-01-01

    The sodium vapor deposition onto a horizontal flat plate above liquid sodium surface was studied. The analysis was performed by assuming that the sodium mist is emitted into the main flow without condensation and then grows up in the main flow and drops on the sodium surface. The effects of growth of sodium mist to the system were investigated. The model of the phenomena is the sodium deposition onto a horizontal flat plate which is placed above the sodium surface with the medium cover gas. One-dimensional analysis can be done. The rate of deposition is greatly reduced when the temperature of the flat plate is lowered. For the analysis of this phenomena, it is assumed that the sodium mist grows by condensation. One of results is that the real state may be the state between the state that the condensation of mist is made in the boundary layer and the state that the mist is condensed in the main flow. Others are that there is no effect of sodium mist condensation on the rate of deposition, and that the rate of the vaporization of sodium is given by the original and the modified model. (Kato, T.)

  2. Fuel vapor pressure (FVAPRS)

    International Nuclear Information System (INIS)

    Mason, R.E.

    1979-04-01

    A subcode (FVAPRS) is described which calculates fuel vapor pressure. This subcode was developed as part of the fuel rod behavior modeling task performed at EG and G Idaho, Inc. The fuel vapor pressure subcode (FVAPRS), is presented and a discussion of literature data, steady state and transient fuel vapor pressure equations and estimates of the standard error of estimate to be expected with the FVAPRS subcode are included

  3. Total Site Heat Integration Considering Pressure Drops

    Directory of Open Access Journals (Sweden)

    Kew Hong Chew

    2015-02-01

    Full Text Available Pressure drop is an important consideration in Total Site Heat Integration (TSHI. This is due to the typically large distances between the different plants and the flow across plant elevations and equipment, including heat exchangers. Failure to consider pressure drop during utility targeting and heat exchanger network (HEN synthesis may, at best, lead to optimistic energy targets, and at worst, an inoperable system if the pumps or compressors cannot overcome the actual pressure drop. Most studies have addressed the pressure drop factor in terms of pumping cost, forbidden matches or allowable pressure drop constraints in the optimisation of HEN. This study looks at the implication of pressure drop in the context of a Total Site. The graphical Pinch-based TSHI methodology is extended to consider the pressure drop factor during the minimum energy requirement (MER targeting stage. The improved methodology provides a more realistic estimation of the MER targets and valuable insights for the implementation of the TSHI design. In the case study, when pressure drop in the steam distribution networks is considered, the heating and cooling duties increase by 14.5% and 4.5%.

  4. Drop size measurements in Venturi scrubbers

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Alonso, D.; Azzopardi, B.J. [Nottingham Univ. (United Kingdom). Dept. of Chemical Engineering; Goncalves, J.A.S.; Coury, J.R. [Universidade Federal de Sao Carlos (Brazil). Departamento de Engenharia Quimica

    2001-07-01

    Venturi scrubbers are high efficiency gas cleaners in which suspended particles are removed from gas streams by drops formed by liquid atomisation, usually in the Venturi throat. The size of the drops formed are of fundamental importance to the performance of the equipment, both in terms of pressure drop and dust removal efficiency. In this study, drop sizes in a cylindrical laboratory-scale Venturi scrubber were measured using a laser diffraction technique. Gas velocity and liquid to gas ratios varied from 50 to 90 m/s and 0.5 to 2.0 1/m{sup 3}, respectively. Water was injected using two different arrangements: either as jets in the throat or as a film just upstream of the convergence. Drop size measurements were performed at three positions in the case of jet injection: two located along the throat, and the last one at the end of the diffuser. The present data shows that the Sauter mean diameter of the spray can be well correlated by the equation of Boll et al. (J. Air Pollut. Control Assoc. 24 (1974) 932). Drop size distributions are satisfactorily represented by a Rosin-Rammler function. This paper also provides a simple method for calculating the parameters of the Rosin-Rammler function. As a result of this work, drop sizes in Venturi scrubbers can be estimated with much higher accuracy. (Author)

  5. “just hanging out with you in my back yard”: Mark Zuckerberg and Mediated Paternalism

    OpenAIRE

    Little Ben; Winch Alison

    2018-01-01

    In a video that showcases a new Facebook feature, Mark Zuckerberg chats to his users, telling them that he’s “just hanging out with you in my backyard.” In this video-which is on his Facebook page-Zuckerberg discloses the domestic space of his backyard, revealing his interaction with family and friends. Depicted hosting a barbeque while watching the electoral debate, Zuckerberg performs an affective white postfeminist paternity (Hamad, 2014) by talking about hunting, eating meat, and being a ...

  6. Sepsis from dropped clips at laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Hussain, Sarwat

    2001-01-01

    We report seven patients in whom five dropped surgical clips and two gallstones were visualized in the peritoneal cavity, on radiological studies. In two, subphrenic abscesses and empyemas developed as a result of dropped clips into the peritoneal cavity during or following laparoscopic cholecystectomy. In one of these two, a clip was removed surgically from the site of an abscess. In two other patients dropped gallstones, and in three, dropped clips led to no complications. These were seen incidentally on studies done for other indications. Abdominal abscess secondary to dropped gallstones is a well-recognized complication of laparoscopic cholecystectomy (LC). We conclude that even though dropped surgical clips usually do not cause problems, they should be considered as a risk additional to other well-known causes of post-LC abdominal sepsis

  7. Purification, crystallization and preliminary crystallographic analysis of biotin protein ligase from Staphylococcus aureus

    International Nuclear Information System (INIS)

    Pendini, Nicole R.; Polyak, Steve W.; Booker, Grant W.; Wallace, John C.; Wilce, Matthew C. J.

    2008-01-01

    The biotin protein ligase from S. aureus has been overexpressed in E. coli, purified, crystallized by the hanging-drop vapour-diffusion method and analysed using X-ray diffraction. Biotin protein ligase from Staphylococcus aureus catalyses the biotinylation of acetyl-CoA carboxylase and pyruvate carboxylase. Recombinant biotin protein ligase from S. aureus has been cloned, expressed and purified. Crystals were grown using the hanging-drop vapour-diffusion method using PEG 8000 as the precipitant at 295 K. X-ray diffraction data were collected to 2.3 Å resolution from crystals using synchrotron X-ray radiation at 100 K. The diffraction was consistent with the tetragonal space group P4 2 2 1 2, with unit-cell parameters a = b = 93.665, c = 131.95

  8. Crystallization and initial X-ray analysis of polyhydroxyalkanoate granule-associated protein from Aeromonas hydrophila

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Minglian; Li, Zhenguo; Zheng, Wei; Lou, Zhiyong [MOE Key Laboratory of Protein Science, Department of Biological Sciences and Biotechnology, Tsinghua University, Beijing 100084 (China); Chen, Guo-Qiang, E-mail: chengq@stu.edu.cn [MOE Key Laboratory of Protein Science, Department of Biological Sciences and Biotechnology, Tsinghua University, Beijing 100084 (China); Multidisciplinary Research Center, Shantou University, Shantou 515063, Guangdong (China)

    2006-08-01

    The phasin PhaP{sub Ah} from A. hydrophila strain 4AK4 was crystallized using the hanging-drop vapour-diffusion method. Polyhydroxyalkanoate (PHA) granule-associated proteins (phasins) were discovered in PHA-accumulating bacteria. They play a crucial role as a structural protein during initial PHA-granule formation and granule growth and also serve as interfaces for granule stabilization in vivo. The phasin PhaP{sub Ah} from Aeromonas hydrophila strain 4AK4 was crystallized using the hanging-drop vapour-diffusion method. Single crystals were cryocooled for X-ray diffraction analysis. The phasin crystals belonged to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 80.8, b = 108.9, c = 134.4 Å.

  9. Micro-splashing by drop impacts

    KAUST Repository

    Thoroddsen, Sigurdur T; Takehara, Kohsei; Etoh, Takeharugoji

    2012-01-01

    We use ultra-high-speed video imaging to observe directly the earliest onset of prompt splashing when a drop impacts onto a smooth solid surface. We capture the start of the ejecta sheet travelling along the solid substrate and show how it breaks up immediately upon emergence from the underneath the drop. The resulting micro-droplets are much smaller and faster than previously reported and may have gone unobserved owing to their very small size and rapid ejection velocities, which approach 100 m s-1, for typical impact conditions of large rain drops. We propose a phenomenological mechanism which predicts the velocity and size distribution of the resulting microdroplets. We also observe azimuthal undulations which may help promote the earliest breakup of the ejecta. This instability occurs in the cusp in the free surface where the drop surface meets the radially ejected liquid sheet. © 2012 Cambridge University Press.

  10. Micro-splashing by drop impacts

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2012-07-18

    We use ultra-high-speed video imaging to observe directly the earliest onset of prompt splashing when a drop impacts onto a smooth solid surface. We capture the start of the ejecta sheet travelling along the solid substrate and show how it breaks up immediately upon emergence from the underneath the drop. The resulting micro-droplets are much smaller and faster than previously reported and may have gone unobserved owing to their very small size and rapid ejection velocities, which approach 100 m s-1, for typical impact conditions of large rain drops. We propose a phenomenological mechanism which predicts the velocity and size distribution of the resulting microdroplets. We also observe azimuthal undulations which may help promote the earliest breakup of the ejecta. This instability occurs in the cusp in the free surface where the drop surface meets the radially ejected liquid sheet. © 2012 Cambridge University Press.

  11. Pressure drop in ET-RR-1

    International Nuclear Information System (INIS)

    Khattab, M.; Mina, A.R.

    1990-01-01

    Measurements of pressure drop through a bundle comprising 16 rods and their lower arrangement grid as well as orifices similar to those of ET-RR-1 core have been done. Experiments are carried out under adiabatic turbulent flow conditions at about 35 degree C. Bundle Reynolds number range is 4 x 10 -2 x 10. Orifices of diameters 4.5, 3.25 or 2.5 cm. are mounted underneath the bundle. The bundle and lower grid pressure drop coefficients are 3.75 and 1.8 respectively. Orifices pressure drop coefficients are 2.65, 19.67 and 53.55 respectively. The ratio of bundle pressure drop to that of 4.5 cm. Orifice diameter is 1.415. The pressure drop coefficients are utilizer to calculate flow through bundles. The flow rate per bundle is 39.1, 20.4 or 13.1 m 3 /hr. Depending on orifice diameter

  12. Controls on fault zone structure and brittle fracturing in the foliated hanging wall of the Alpine Fault

    Science.gov (United States)

    Williams, Jack N.; Toy, Virginia G.; Massiot, Cécile; McNamara, David D.; Smith, Steven A. F.; Mills, Steven

    2018-04-01

    Three datasets are used to quantify fracture density, orientation, and fill in the foliated hanging wall of the Alpine Fault: (1) X-ray computed tomography (CT) images of drill core collected within 25 m of its principal slip zones (PSZs) during the first phase of the Deep Fault Drilling Project that were reoriented with respect to borehole televiewer images, (2) field measurements from creek sections up to 500 m from the PSZs, and (3) CT images of oriented drill core collected during the Amethyst Hydro Project at distances of ˜ 0.7-2 km from the PSZs. Results show that within 160 m of the PSZs in foliated cataclasites and ultramylonites, gouge-filled fractures exhibit a wide range of orientations. At these distances, fractures are interpreted to have formed at relatively high confining pressures and/or in rocks that had a weak mechanical anisotropy. Conversely, at distances greater than 160 m from the PSZs, fractures are typically open and subparallel to the mylonitic or schistose foliation, implying that fracturing occurred at low confining pressures and/or in rocks that were mechanically anisotropic. Fracture density is similar across the ˜ 500 m width of the field transects. By combining our datasets with measurements of permeability and seismic velocity around the Alpine Fault, we further develop the hierarchical model for hanging-wall damage structure that was proposed by Townend et al. (2017). The wider zone of foliation-parallel fractures represents an outer damage zone that forms at shallow depths. The distinct inner damage zone. This zone is interpreted to extend towards the base of the seismogenic crust given that its width is comparable to (1) the Alpine Fault low-velocity zone detected by fault zone guided waves and (2) damage zones reported from other exhumed large-displacement faults. In summary, a narrow zone of fracturing at the base of the Alpine Fault's hanging-wall seismogenic crust is anticipated to widen at shallow depths, which is

  13. Investigation of heat transfer and pressure drop of CO(2) two-phase flow in a horizontal minichannel

    CERN Document Server

    Wu, J; Haug, F; Franke, C; Bremer, J; Eisel, T; Koettig, T

    2011-01-01

    An innovative cooling system based on evaporative CO(2) two-phase flow is under investigation for the tracker detectors upgrade at CERN (European Organization for Nuclear Research). The radiation hardness and the excellent thermodynamic properties emphasize carbon dioxide as a cooling agent in the foreseen minichannels. A circular stainless steel tube in horizontal orientation with an inner diameter of 1.42 mm and a length of 0.3 m has been used as a test section to perform the step-wise scanning of the vapor quality in the entire two-phase region. To characterize the heat transfer and the pressure drop depending on the vapor quality in the tube, measurements have been performed by varying the mass flux from 300 to 600 kg/m(2) s, the heat flux from 7.5 to 29.8 kW/m(2) and the saturation temperature from -40 to 0 degrees C (reduced pressures from 0.136 to 0.472). Heat transfer coefficients between 4 kW/m(2) K and 28 kW/m(2) K and pressure gradients up to 75 kPa/m were registered. The measured data was analyzed...

  14. Vapor generation methods for explosives detection research

    Energy Technology Data Exchange (ETDEWEB)

    Grate, Jay W.; Ewing, Robert G.; Atkinson, David A.

    2012-12-01

    The generation of calibrated vapor samples of explosives compounds remains a challenge due to the low vapor pressures of the explosives, adsorption of explosives on container and tubing walls, and the requirement to manage (typically) multiple temperature zones as the vapor is generated, diluted, and delivered. Methods that have been described to generate vapors can be classified as continuous or pulsed flow vapor generators. Vapor sources for continuous flow generators are typically explosives compounds supported on a solid support, or compounds contained in a permeation or diffusion device. Sources are held at elevated isothermal temperatures. Similar sources can be used for pulsed vapor generators; however, pulsed systems may also use injection of solutions onto heated surfaces with generation of both solvent and explosives vapors, transient peaks from a gas chromatograph, or vapors generated by s programmed thermal desorption. This article reviews vapor generator approaches with emphasis on the method of generating the vapors and on practical aspects of vapor dilution and handling. In addition, a gas chromatographic system with two ovens that is configurable with up to four heating ropes is proposed that could serve as a single integrated platform for explosives vapor generation and device testing. Issues related to standards, calibration, and safety are also discussed.

  15. Drop trampoline

    Science.gov (United States)

    Chantelot, Pierre; Coux, Martin; Clanet, Christophe; Quere, David

    2017-11-01

    Superhydrophobic substrates inspired from the lotus leaf have the ability to reflect impacting water drops. They do so very efficiently and contact lasts typically 10 ms for millimetric droplets. Yet unlike a lotus leaf most synthetic substrates are rigid. Focusing on the interplay between substrate flexibility and liquid repellency might allow us to understand the dynamic properties of natural surfaces. We perform liquid marbles impacts at velocity V onto thin ( 0.01 mm) stretched circular PDMS membranes. We obtain contact time reductions of up to 70%. The bouncing mechanism is drastically modified compared to that on a rigid substrate: the marble leaves the substrate while it is still spread in a disk shape as it is kicked upwards by the membrane. We show that the bouncing is controlled by an interplay between the dynamics of the drop and the membrane.

  16. Drop Spreading with Random Viscosity

    Science.gov (United States)

    Xu, Feng; Jensen, Oliver

    2016-11-01

    Airway mucus acts as a barrier to protect the lung. However as a biological material, its physical properties are known imperfectly and can be spatially heterogeneous. In this study we assess the impact of these uncertainties on the rate of spreading of a drop (representing an inhaled aerosol) over a mucus film. We model the film as Newtonian, having a viscosity that depends linearly on the concentration of a passive solute (a crude proxy for mucin proteins). Given an initial random solute (and hence viscosity) distribution, described as a Gaussian random field with a given correlation structure, we seek to quantify the uncertainties in outcomes as the drop spreads. Using lubrication theory, we describe the spreading of the drop in terms of a system of coupled nonlinear PDEs governing the evolution of film height and the vertically-averaged solute concentration. We perform Monte Carlo simulations to predict the variability in the drop centre location and width (1D) or area (2D). We show how simulation results are well described (at much lower computational cost) by a low-order model using a weak disorder expansion. Our results show for example how variability in the drop location is a non-monotonic function of the solute correlation length increases. Engineering and Physical Sciences Research Council.

  17. Thermocapillary reorientation of Janus drops

    Science.gov (United States)

    Rosales, Rodolfo; Saenz, Pedro

    2017-11-01

    Janus drops, named after the Ancient Roman two-faced god, are liquid drops formed from two immiscible fluids. Experimental observations indicate that a Janus drop may re-orientate in response to an applied external thermal gradient due to the Marangoni effect. Depending on the angle between the interior interface and the direction of the temperature gradient, disparities in the physical properties of the constituent liquids may lead to asymmetries in the thermocapillary flow. As a result, the drop will move along a curved path until a torque-free configuration is achieved, point after which it will continue on a straight trajectory. Here, we present the results of a theoretical investigation of this realignment phenomenon in the Stokes regime and in the limit of non-deformable interfaces. A 3D semi-analytical method in terms of polar spherical harmonics is developed to characterize and rationalize the hydrodynamic response (forces and torques), flow (velocity and temperature distribution) and trajectory of a Janus drop moving during the temperature-driven reorientation process. Furthermore, we discuss how this phenomenon may be exploited to develop dynamically reconfigurable micro-lenses. This work was partially supported by the US National Science Foundation through Grants DMS-1614043 and DMS-1719637.

  18. A Study on the Violent Interactions of an Immiscible Drop impacting on a Superheated Pool

    KAUST Repository

    Alchalabi, Mohamad

    2014-05-01

    ABSTRACT A Study on the Violent Interactions of an Immiscible Drop Impacting on a Superheated Pool Mohamad Alchalabi The interactions between two immiscible liquids of different temperatures can be violent to the extent of causing harm to individuals, or damage to equipment, especially when used in the industry. Only a few studies investigated these interactions but they could not produce the violent interactions often reported by the industry, and therefore their results did not help much to develop clear understanding of the dynamics of these interactions. In this work, a high speed imaging system operated at 100,000 frames per second was utilized to record the events and phenomena taking place upon the impact of Perfluorohexane droplet at room temperature onto a hot soybean oil pool at temperatures as high as 300 ºC. The impact velocity was varied by varying the height of the droplet before it pinches off under its own weight. The recorded events identified the occurrence of vortex ring vapor explosions, weak and strong nucleate boiling, and film boiling. An impact velocity vs. oil temperature diagram identifying the regions in which each of these phenomena takes place was generated, and the dynamics driving their occurrences were explored. The vortex ring vapor explosions were found to become less violent as the impact velocity was increased, which was attributed to the existence of a smaller amount of liquid Perfluorohexane within the rings at high speed impacts, which does evaporate but does not expand violently. Weak nucleate boiling occurred at very high impact velocities relatively. As the temperature is increased, however, they start 5 turning into strong nucleate boiling. The strong nucleate boiling usually starts right upon impact, and when the temperature of the oil at one impact velocity is increased, it starts turning into film boiling, in which the liquid Perfluorohexane is covered by a vapor layer of its own vapor.

  19. Muscle activity and spine load during anterior chain whole body linkage exercises: the body saw, hanging leg raise and walkout from a push-up.

    Science.gov (United States)

    McGill, Stuart; Andersen, Jordan; Cannon, Jordan

    2015-01-01

    This study examined anterior chain whole body linkage exercises, namely the body saw, hanging leg raise and walkout from a push-up. Investigation of these exercises focused on which particular muscles were challenged and the magnitude of the resulting spine load. Fourteen males performed the exercises while muscle activity, external force and 3D body segment motion were recorded. A sophisticated and anatomically detailed 3D model used muscle activity and body segment kinematics to estimate muscle force, and thus sensitivity to each individual's choice of motor control for each task. Gradations of muscle activity and spine load characteristics were observed across tasks. On average, the hanging straight leg raise created approximately 3000 N of spine compression while the body saw created less than 2500 N. The hanging straight leg raise created the highest challenge to the abdominal wall (>130% MVC in rectus abdominis, 88% MVC in external oblique). The body saw resulted in almost 140% MVC activation of the serratus anterior. All other exercises produced substantial abdominal challenge, although the body saw did so in the most spine conserving way. These findings, along with consideration of an individual's injury history, training goals and current fitness level, should assist in exercise choice and programme design.

  20. Trace mercury determination in drinking and natural water after preconcentration and separation by DLLME-SFO method coupled with cold vapor atomic absorption spectrometry

    OpenAIRE

    Abdollahi Atousa; Amirkavehei Mooud; Gheisari Mohammad Mehdi; Tadayon Fariba

    2014-01-01

    A novel dispersive liquid–liquid microextraction based on solidification of floating organic drop (DLLME-SFO) for simultaneous separation/preconcentration of ultra trace amounts of mercury was used. A method based on amalgamation was used for collection of gaseous mercury on gold coated sand (Gold trap). The concentration of mercury was determined by cold vapor atomic absorption spectrometry (CV-AAS). The DLLME-SFO behavior of mercury by using dithizone as complexing agent was systematically ...

  1. The vaporization enthalpy and vapor pressure of S (+)-methamphetamine at T = 298.15 K by correlation gas chromatography

    International Nuclear Information System (INIS)

    Thornton, Melissa; Gobble, Chase; Chickos, James

    2014-01-01

    Highlights: • The vaporization enthalpy of (d)-methamphetamine was measured. • The vapor pressure of (d)-methamphetamine as a function of temperature was evaluated. • The vapor pressure of 4-benzylpiperidine as a function of temperature was evaluated. - Abstract: The vaporization enthalpy and vapor pressure of S (+)-methamphetamine is evaluated by correlation-gas chromatography. A vaporization enthalpy of (58.7 ± 4.3) kJ · mol −1 and a vapor pressure, p = (38 ± 9) Pa has been obtained using a variety of secondary aliphatic amines as standards. In addition, equations describing the vapor pressure temperature dependence are provided for standards and S (+)-methamphetamine covering the temperature range from T = 298.15 K to the boiling temperature. Boiling temperatures are reproduced within an interval of 8 K or less

  2. CPAS Preflight Drop Test Analysis Process

    Science.gov (United States)

    Englert, Megan E.; Bledsoe, Kristin J.; Romero, Leah M.

    2015-01-01

    Throughout the Capsule Parachute Assembly System (CPAS) drop test program, the CPAS Analysis Team has developed a simulation and analysis process to support drop test planning and execution. This process includes multiple phases focused on developing test simulations and communicating results to all groups involved in the drop test. CPAS Engineering Development Unit (EDU) series drop test planning begins with the development of a basic operational concept for each test. Trajectory simulation tools include the Flight Analysis and Simulation Tool (FAST) for single bodies, and the Automatic Dynamic Analysis of Mechanical Systems (ADAMS) simulation for the mated vehicle. Results are communicated to the team at the Test Configuration Review (TCR) and Test Readiness Review (TRR), as well as at Analysis Integrated Product Team (IPT) meetings in earlier and intermediate phases of the pre-test planning. The ability to plan and communicate efficiently with rapidly changing objectives and tight schedule constraints is a necessity for safe and successful drop tests.

  3. Observation and particle simulation of vaporized W, Mo, and Be in PISCES-B plasma for vapor-shielding studies

    Directory of Open Access Journals (Sweden)

    K. Ibano

    2017-08-01

    Full Text Available Interactions of Tungsten (W, Molybdenum (Mo, and Beryllium (Be vapors with a steady-state plasma were studied by the PISCES-B liner plasma experiments as well as Particle-In-Cell (PIC simulations for the understanding of vapor-shielding phenomena. Effective cooling of the plasma by laser-generated Be vapor was observed in PISCES-B. On the other hand, no apparent cooling was observed for W and Mo vapors. The PIC simulation explains these experimental observations of the difference between low-Z and high-Z vapors. Decrease of electron temperature due to the vapor ejection was observed in case of a simulation of the Be vapor. As for the W vapor, it was found that the plasma cooling is localized only near the wall at a higher electron density plasma (∼1019m−3. On the other hand, the appreciable plasma cooling can be observed in a lower density plasma (∼1018m−3 for the W vapor.

  4. Blood drop patterns: Formation and applications.

    Science.gov (United States)

    Chen, Ruoyang; Zhang, Liyuan; Zang, Duyang; Shen, Wei

    2016-05-01

    The drying of a drop of blood or plasma on a solid substrate leads to the formation of interesting and complex patterns. Inter- and intra-cellular and macromolecular interactions in the drying plasma or blood drop are responsible for the final morphologies of the dried patterns. Changes in these cellular and macromolecular components in blood caused by diseases have been suspected to cause changes in the dried drop patterns of plasma and whole blood, which could be used as simple diagnostic tools to identify the health of humans and livestock. However, complex physicochemical driving forces involved in the pattern formation are not fully understood. This review focuses on the scientific development in microscopic observations and pattern interpretation of dried plasma and whole blood samples, as well as the diagnostic applications of pattern analysis. Dried drop patterns of plasma consist of intricate visible cracks in the outer region and fine structures in the central region, which are mainly influenced by the presence and concentration of inorganic salts and proteins during drying. The shrinkage of macromolecular gel and its adhesion to the substrate surface have been thought to be responsible for the formation of the cracks. Dried drop patterns of whole blood have three characteristic zones; their formation as functions of drying time has been reported in the literature. Some research works have applied engineering treatment to the evaporation process of whole blood samples. The sensitivities of the resultant patterns to the relative humidity of the environment, the wettability of the substrates, and the size of the drop have been reported. These research works shed light on the mechanisms of spreading, evaporation, gelation, and crack formation of the blood drops on solid substrates, as well as on the potential applications of dried drop patterns of plasma and whole blood in diagnosis. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  5. Passive vapor extraction feasibility study

    International Nuclear Information System (INIS)

    Rohay, V.J.

    1994-01-01

    Demonstration of a passive vapor extraction remediation system is planned for sites in the 200 West Area used in the past for the disposal of waste liquids containing carbon tetrachloride. The passive vapor extraction units will consist of a 4-in.-diameter pipe, a check valve, a canister filled with granular activated carbon, and a wind turbine. The check valve will prevent inflow of air that otherwise would dilute the soil gas and make its subsequent extraction less efficient. The granular activated carbon is used to adsorb the carbon tetrachloride from the air. The wind turbine enhances extraction rates on windy days. Passive vapor extraction units will be designed and operated to meet all applicable or relevant and appropriate requirements. Based on a cost analysis, passive vapor extraction was found to be a cost-effective method for remediation of soils containing lower concentrations of volatile contaminants. Passive vapor extraction used on wells that average 10-stdft 3 /min air flow rates was found to be more cost effective than active vapor extraction for concentrations below 500 parts per million by volume (ppm) of carbon tetrachloride. For wells that average 5-stdft 3 /min air flow rates, passive vapor extraction is more cost effective below 100 ppm

  6. Hydraulic Behavior in The Downflow Hanging Sponge Bioreactor

    Directory of Open Access Journals (Sweden)

    Izarul Machdar

    2016-12-01

    Full Text Available Performance efficiency in a Downflow Hanging Sponge (DHS bioreactor is associated with the amount of time that a wastewater remains in the bioreactor. The bioreactor is considered as a plug flow reactor and its hydraulic residence time (HRT depends on the void volume of packing material and the flow rate. In this study, hydraulic behavior of DHS bioreactor was investigated by using tracer method. Two types of sponge module covers, cylindrical plastic frame (module-1 and plastic hair roller (module-2, were investigated and compared. A concentrated NaCl solution used as an inert tracer and input as a pulse at the inlet of DHS bioreactor. Analysis of the residence time distribution (RTD curves provided interpretation of the index distribution or holdup water (active volume, the degree of short-circuiting, number of tanks in series (the plug flow characteristic, and the dispersion number. It was found that the actual HRT was primarily shorter than theoretical HRT of each test. Holdup water of the DHS bioreactor ranged from 60% to 97% and 36% to 60% of module-1 and module-2, respectively. Eventhough module-1 has higher effective volume than module-2, result showed that the dispersion numbers of the two modules were not significant difference. Furthermore, N-values were found larger at a higher flow rate. It was concluded that a DHS bioreactor design should incorporated a combination of water distributor system, higher loading rate at startup process to generate a hydraulic behavior closer to an ideal plug flow.ABSTRAKEfisiensi unjuk kerja bioreactor Downflow Hanging Sponge (DHS berkaitan dengan lamanya waktu tinggal limbah berada di dalam bioreaktor tersebut. Bioreaktor DHS dianggap sebagai seuatu reaktor aliran sumbat (plug flow dimana waktu tinggal hidraulik (HRT tergantung pada volume pori material isian dan laju alir. Dua jenis modul digunakan dalam penelitian ini, yang diberi nama dengan module-1 dan module-2 untuk melihat pengaruh jenis modul

  7. Penerapan Technical Barrier to Trade melalui Pelabelan (Hang Tag Identitas Budaya pada Produk Batik

    Directory of Open Access Journals (Sweden)

    Siti Zulaekah

    2014-12-01

    Full Text Available Artikel ini bertujuan menawarkan ide/gagasan baru tentang formulasi perlindungan melalui penerapan hambatan teknis perdagangan (technical barrier to trade/TBT berupa pelabelan identitas budaya (hang tag dalam mekanisme perdagangan internasional pada produk batik.Sebagaimana diketahui, perlindungan dalam bentuk hambatan non tariff (non tariff barrier khususnya TBT yang menyangkut pelabelan produk yangberlaku selama ini sepanjang pengetahuan peneliti baru sebatas alasan keamanan pangan, kesehatan, dan lingkungan. Negara-negara yang menerap- kan hambatan dalam pelabelan di luar kategori tersebut pun masih sangat terbatas.Untuk menjawab permasalahan tersebut, penelitian ini dirancang dengan menggunakan pendekatan Hukum Normatif dengan desain penelitian kualita- tif. Penelitian menggunakan teknik participatory observation dan focus group discussion sebagai metode pengumpulan data primer. Pengumpulan data sekunder dilakukan melalui telaah kepustakaan dan inventarisasi peraturan perundang-undangan untuk data yang berupa bahan hukum. Agar data (teru- tama data primer yang diperoleh teruji keabsahannya, penelitian ini meman- faatkan metode trianggulasi yang menyatu dan tidak terpisahkan dari kegia- tan pengumpulan data primer tersebut. Analisis data menggunakan model Miles dan Huberman yang pada prinsipnya meliputi 3 (tiga tahapan yakni reduksi data, display data, dan verifikasi atau penarikan kesimpulan.Hasil penelitian menunjukkan bahwa Pemerintah Indonesia sebenarnya telah menerapkan hambatan non tarif dalam bentuk TBT pada produk batik melalui Peraturan Menteri Perindustrian tentang batikmark “batik INDONE- SIA”. Meski demikian, pelabelan tersebut masih membutuhkan rincian lagi dalam bentuk pelabelan identitas budaya sehingga maksud pelestarian batik sebagaimana diamanatkan Unesco pada Pemerintah Indonesia diharapkan menjadi terwujud.Keywords : Non Tariff Barrier, Technical Barrier to Trade,   Hang Tag, Pelabelan Identitas  Budaya

  8. A heated vapor cell unit for dichroic atomic vapor laser lock in atomic rubidium.

    Science.gov (United States)

    McCarron, Daniel J; Hughes, Ifan G; Tierney, Patrick; Cornish, Simon L

    2007-09-01

    The design and performance of a compact heated vapor cell unit for realizing a dichroic atomic vapor laser lock (DAVLL) for the D(2) transitions in atomic rubidium is described. A 5 cm long vapor cell is placed in a double-solenoid arrangement to produce the required magnetic field; the heat from the solenoid is used to increase the vapor pressure and correspondingly the DAVLL signal. We have characterized experimentally the dependence of important features of the DAVLL signal on magnetic field and cell temperature. For the weaker transitions both the amplitude and gradient of the signal are increased by an order of magnitude.

  9. A heated vapor cell unit for dichroic atomic vapor laser lock in atomic rubidium

    International Nuclear Information System (INIS)

    McCarron, Daniel J.; Hughes, Ifan G.; Tierney, Patrick; Cornish, Simon L.

    2007-01-01

    The design and performance of a compact heated vapor cell unit for realizing a dichroic atomic vapor laser lock (DAVLL) for the D 2 transitions in atomic rubidium is described. A 5 cm long vapor cell is placed in a double-solenoid arrangement to produce the required magnetic field; the heat from the solenoid is used to increase the vapor pressure and correspondingly the DAVLL signal. We have characterized experimentally the dependence of important features of the DAVLL signal on magnetic field and cell temperature. For the weaker transitions both the amplitude and gradient of the signal are increased by an order of magnitude

  10. Cloning, expression, purification, crystallization and preliminary X-ray diffraction analysis of the regulator AcrR from Escherichia coli

    International Nuclear Information System (INIS)

    Li, Ming; Qiu, Xi; Su, Chih-Chia; Long, Feng; Gu, Ruoyu; McDermott, Gerry; Yu, Edward W.

    2006-01-01

    The transcriptional regulator AcrR from Escherichia coli has been cloned, overexpressed, purified and crystallized and X-ray diffraction data have been collected to a resolution of 2.5 Å. This paper describes the cloning, expression, purification and preliminary X-ray data analysis of the AcrR regulatory protein. The Escherichia coli AcrR is a member of the TetR family of transcriptional regulators. It regulates the expression of the AcrAB multidrug transporter. Recombinant AcrR with a 6×His tag at the C-terminus was expressed in E. coli and purified by metal-affinity chromatography. The protein was crystallized using hanging-drop vapor diffusion. X-ray diffraction data were collected from cryocooled crystals at a synchrotron light source. The best crystal diffracted to 2.5 Å. The space group was determined to be P3 2 , with unit-cell parameters a = b = 46.61, c = 166.16 Å

  11. Crystallization and Preliminary X-ray Analysis of Bacteriophasge T4 UvsY Recombination Mediator Protein

    International Nuclear Information System (INIS)

    Xu, H.; Beernink, H.; Rould, M.; Morrical, S.

    2006-01-01

    Bacteriophage T4 UvsY protein is considered to be the prototype of recombination mediator proteins, a class of proteins which assist in the loading of recombinases onto DNA. Wild-type and Se-substituted UvsY protein have been expressed and purified and crystallized by hanging-drop vapor diffusion. The crystals diffract to 2.4 (angstrom) using in-house facilities and to 2.2 (angstrom) at NSLS, Brookhaven National Laboratory. The crystals belong to space group P422, P4 2 22, P42 1 2 or P4 2 2 1 2, the ambiguity arising from pseudo-centering, with unit-cell parameters a = b = 76.93, c = 269.8 (angstrom). Previous biophysical characterization of UvsY indicates that it exists primarily as a hexamer in solution. Along with the absence of a crystallographic threefold, this suggests that the asymmetric unit of these crystals is likely to contain either three monomers, giving a solvent content of 71%, or six monomers, giving a solvent content of 41%

  12. Crystallization and preliminary X-ray characterization of the glpX-encoded class II fructose-1,6-bisphosphatase from Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Gutka, Hiten J.; Franzblau, Scott G.; Movahedzadeh, Farahnaz; Abad-Zapatero, Cele

    2011-01-01

    The crystallization and preliminary X-ray crystallographic analysis of the glpX-encoded class II fructose-1,6-bisphosphatase from M. tuberculosis in the apo form is reported. Fructose-1,6-bisphosphatase (FBPase; EC 3.1.3.11), which is a key enzyme in gluconeogenesis, catalyzes the hydrolysis of fructose 1,6-bisphosphate to form fructose 6-phosphate and orthophosphate. The present investigation reports the crystallization and preliminary crystallographic studies of the glpX-encoded class II FBPase from Mycobacterium tuberculosis H37Rv. The recombinant protein, which was cloned using an Escherichia coli expression system, was purified and crystallized using the hanging-drop vapor-diffusion method. The crystals diffracted to a resolution of 2.7 Å and belonged to the hexagonal space group P6 1 22, with unit-cell parameters a = b = 131.3, c = 143.2 Å. The structure has been solved by molecular replacement and is currently undergoing refinement

  13. An experimental analysis of flow boiling and pressure drop in a brazed plate heat exchanger for organic Rankine cycle power systems

    DEFF Research Database (Denmark)

    Desideri, Adriano; Zhang, Ji; Kærn, Martin Ryhl

    2017-01-01

    Organic Rankine cycle power systems for low quality waste heat recovery applications can play a major role in achieving targets of increasing industrial processes efficiency and thus reducing the emissions of greenhouse gases. Low capacity organic Rankine cycle systems are equipped with brazed...... and pressure drop during vaporization at typical temperatures for low quality waste heat recovery organic Rankine cycle systems are presented for the working fluids HFC-245fa and HFO-1233zd. The experiments were carried out at saturation temperatures of 100°C, 115°C and 130°C and inlet and outlet qualities...

  14. Comparison of the Hang High-Pull and Loaded Jump Squat for the Development of Vertical Jump and Isometric Force-Time Characteristics.

    Science.gov (United States)

    Oranchuk, Dustin J; Robinson, Tracey L; Switaj, Zachary J; Drinkwater, Eric J

    2017-04-15

    Weightlifting movements have high skill demands and require expert coaching. Loaded jumps have a comparably lower skill demand, but may be similarly effective for improving explosive performance. The purpose of this study was to compare vertical jump performance, isometric force, and rate of force development (RFD) following a ten-week intervention employing the hang high-pull (hang-pull) or trap-bar jump squat (jump-squat). Eighteen NCAA Division II swimmers (8 males, 10 females) with at least one year of resistance training experience volunteered to participate. Testing included the squat jump (SJ), countermovement jump (CMJ) and the isometric mid-thigh pull (IMTP). Vertical ground reaction forces were analyzed to obtain jump height and relative peak power. Relative peak force, peak RFD and relative force at five time bands were obtained from the IMTP. Subjects were randomly assigned to either a hang-pull (n = 9) or jump-squat (n = 9) training group and completed a ten-week, volume-equated, periodized training program. While there was a significant main effect of training for both groups, no statistically significant between-group differences were found (p ≥ 0.17) for any of the dependent variables. However, medium effect sizes in favor of the jump-squat training group were seen in SJ height (d = 0.56) and SJ peak power (d = 0.69). Loaded jumps seem equally effective as weightlifting derivatives for improving lower-body power in experienced athletes. Since loaded jumps require less skill and less coaching expertise than weightlifting, loaded jumps should be considered where coaching complex movements is difficult.

  15. Petrophysical, Geochemical, and Hydrological Evidence for Extensive Fracture-Mediated Fluid and Heat Transport in the Alpine Fault's Hanging-Wall Damage Zone

    Science.gov (United States)

    Townend, John; Sutherland, Rupert; Toy, Virginia G.; Doan, Mai-Linh; Célérier, Bernard; Massiot, Cécile; Coussens, Jamie; Jeppson, Tamara; Janku-Capova, Lucie; Remaud, Léa.; Upton, Phaedra; Schmitt, Douglas R.; Pezard, Philippe; Williams, Jack; Allen, Michael John; Baratin, Laura-May; Barth, Nicolas; Becroft, Leeza; Boese, Carolin M.; Boulton, Carolyn; Broderick, Neil; Carpenter, Brett; Chamberlain, Calum J.; Cooper, Alan; Coutts, Ashley; Cox, Simon C.; Craw, Lisa; Eccles, Jennifer D.; Faulkner, Dan; Grieve, Jason; Grochowski, Julia; Gulley, Anton; Hartog, Arthur; Henry, Gilles; Howarth, Jamie; Jacobs, Katrina; Kato, Naoki; Keys, Steven; Kirilova, Martina; Kometani, Yusuke; Langridge, Rob; Lin, Weiren; Little, Tim; Lukacs, Adrienn; Mallyon, Deirdre; Mariani, Elisabetta; Mathewson, Loren; Melosh, Ben; Menzies, Catriona; Moore, Jo; Morales, Luis; Mori, Hiroshi; Niemeijer, André; Nishikawa, Osamu; Nitsch, Olivier; Paris, Jehanne; Prior, David J.; Sauer, Katrina; Savage, Martha K.; Schleicher, Anja; Shigematsu, Norio; Taylor-Offord, Sam; Teagle, Damon; Tobin, Harold; Valdez, Robert; Weaver, Konrad; Wiersberg, Thomas; Zimmer, Martin

    2017-12-01

    Fault rock assemblages reflect interaction between deformation, stress, temperature, fluid, and chemical regimes on distinct spatial and temporal scales at various positions in the crust. Here we interpret measurements made in the hanging-wall of the Alpine Fault during the second stage of the Deep Fault Drilling Project (DFDP-2). We present observational evidence for extensive fracturing and high hanging-wall hydraulic conductivity (˜10-9 to 10-7 m/s, corresponding to permeability of ˜10-16 to 10-14 m2) extending several hundred meters from the fault's principal slip zone. Mud losses, gas chemistry anomalies, and petrophysical data indicate that a subset of fractures intersected by the borehole are capable of transmitting fluid volumes of several cubic meters on time scales of hours. DFDP-2 observations and other data suggest that this hydrogeologically active portion of the fault zone in the hanging-wall is several kilometers wide in the uppermost crust. This finding is consistent with numerical models of earthquake rupture and off-fault damage. We conclude that the mechanically and hydrogeologically active part of the Alpine Fault is a more dynamic and extensive feature than commonly described in models based on exhumed faults. We propose that the hydrogeologically active damage zone of the Alpine Fault and other large active faults in areas of high topographic relief can be subdivided into an inner zone in which damage is controlled principally by earthquake rupture processes and an outer zone in which damage reflects coseismic shaking, strain accumulation and release on interseismic timescales, and inherited fracturing related to exhumation.

  16. High temperature vapors science and technology

    CERN Document Server

    Hastie, John

    2012-01-01

    High Temperature Vapors: Science and Technology focuses on the relationship of the basic science of high-temperature vapors to some areas of discernible practical importance in modern science and technology. The major high-temperature problem areas selected for discussion include chemical vapor transport and deposition; the vapor phase aspects of corrosion, combustion, and energy systems; and extraterrestrial high-temperature species. This book is comprised of seven chapters and begins with an introduction to the nature of the high-temperature vapor state, the scope and literature of high-temp

  17. Copper-vapor-catalyzed chemical vapor deposition of graphene on dielectric substrates

    Science.gov (United States)

    Yang, Chao; Wu, Tianru; Wang, Haomin; Zhang, Xuefu; Shi, Zhiyuan; Xie, Xiaoming

    2017-07-01

    Direct synthesis of high-quality graphene on dielectric substrates is important for its application in electronics. In this work, we report the process of copper-vapor-catalyzed chemical vapor deposition of high-quality and large graphene domains on various dielectric substrates. The copper vapor plays a vital role on the growth of transfer-free graphene. Both single-crystal domains that are much larger than previous reports and high-coverage graphene films can be obtained by adjusting the growth duration. The quality of the obtained graphene was verified to be comparable with that of graphene grown on Cu foil. The progress reported in this work will aid the development of the application of transfer-free graphene in the future.

  18. Estimated vapor pressure for WTP process streams

    Energy Technology Data Exchange (ETDEWEB)

    Pike, J. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Poirier, M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-01-01

    Design assumptions during the vacuum refill phase of the Pulsed Jet Mixers (PJMs) in the Hanford Waste Treatment and Immobilization Plant (WTP) equate the vapor pressure of all process streams to that of water when calculating the temperature at which the vacuum refill is reduced or eliminated. WTP design authority asked the authors to assess this assumption by performing calculations on proposed feed slurries to calculate the vapor pressure as a function of temperature. The vapor pressure was estimated for each WTP waste group. The vapor pressure suppression caused by dissolved solids is much greater than the increase caused by organic components such that the vapor pressure for all of the waste group compositions is less than that of pure water. The vapor pressure for each group at 145°F ranges from 81% to 98% of the vapor pressure of water. If desired, the PJM could be operated at higher temperatures for waste groups with high dissolved solids that suppress vapor pressure. The SO4 group with the highest vapor pressure suppression could be operated up to 153°F before reaching the same vapor pressure of water at 145°F. However, most groups would reach equivalent vapor pressure at 147 to 148°F. If any of these waste streams are diluted, the vapor pressure can exceed the vapor pressure of water at mass dilution ratios greater than 10, but the overall effect is less than 0.5%.

  19. A numerical investigation of vapor intrusion--the dynamic response of contaminant vapors to rainfall events.

    Science.gov (United States)

    Shen, Rui; Pennell, Kelly G; Suuberg, Eric M

    2012-10-15

    The U.S. government and various agencies have published guidelines for field investigation of vapor intrusion, most of which suggest soil gas sampling as an integral part of the investigation. Contaminant soil gas data are often relatively more stable than indoor air vapor concentration measurements, but meteorological conditions might influence soil gas values. Although a few field and numerical studies have considered some temporal effects on soil gas vapor transport, a full explanation of the contaminant vapor concentration response to rainfall events is not available. This manuscript seeks to demonstrate the effects on soil vapor transport during and after different rainfall events, by applying a coupled numerical model of fluid flow and vapor transport. Both a single rainfall event and seasonal rainfall events were modeled. For the single rainfall event models, the vapor response process could be divided into three steps: namely, infiltration, water redistribution, and establishment of a water lens atop the groundwater source. In the infiltration step, rainfall intensity was found to determine the speed of the wetting front and wash-out effect on the vapor. The passage of the wetting front led to an increase of the vapor concentration in both the infiltration and water redistribution steps and this effect is noted at soil probes located 1m below the ground surface. When the mixing of groundwater with infiltrated water was not allowed, a clean water lens accumulated above the groundwater source and led to a capping effect which can reduce diffusion rates of contaminant from the source. Seasonal rainfall with short time intervals involved superposition of the individual rainfall events. This modeling results indicated that for relatively deeper soil that the infiltration wetting front could not flood, the effects were damped out in less than a month after rain; while in the long term (years), possible formation of a water lens played a larger role in determining

  20. Hydrothermal waves in evaporating sessile drops

    OpenAIRE

    Brutin, D.; Rigollet, F.; Niliot, C. Le

    2009-01-01

    Drop evaporation is a simple phenomena but still unclear concerning the mechanisms of evaporation. A common agreement of the scientific community based on experimental and numerical work evidences that most of the evaporation occurs at the triple line. However, the rate of evaporation is still empirically predicted due to the lack of knowledge on the convection cells which develop inside the drop under evaporation. The evaporation of sessile drop is more complicated than it appears due to the...

  1. An Experimental Study on the Dynamics of a Single Droplet Vapor Explosion

    International Nuclear Information System (INIS)

    Concilio Hansson, Roberta

    2010-01-01

    correlation between the coolant temperature and the molten droplet deformation/prefragmentation during the first bubble dynamics cycle. The SHARP observations followed by further analysis leads to a hypothesis about a novel phenomenon called pre-conditioning , according to which dynamics of the first bubble-dynamics cycle and the ability of the melt drop to deform/pre-fragment dictate the subsequent explosivity of the so-triggered droplet. The effect of non-condensable gases on the perceived mechanisms was investigated on the MISTEE-NCG test campaign, in which a considerable amount of non-condensable gases (NCG) are present in the film that enfolds the molten droplet. The SHARP images for the MISTEE-NCG tests were analyzed and special attention was given to the morphology (aspect ratio) and dynamics of the air/ vapor bubble, as well as the melt drop preconditioning and interaction energetics. Analysis showed two main aspects when compared to the MISTEE test series (without entrapped air). First, the investigation showed that the melt preconditioning still strongly depends on the coolant subcooling. Second, in respect to the energetics, the tests consistently showed a reduced conversion ratio compared to that of the MISTEE test series. The effect of the melt material in the steam explosion triggerability was also summoned, since it would in principle directly implicate the melt preconditioning. Since a number of the thermo-physical properties of the material would influence the triggering process, we focused on the material properties by using the same dioxide material with difference concentrations, i.e. eutectic and non-eutectic. Unfortunately, due to the high melt superheat the possible differences were not perceived. Thus, in addition to other materials, lower melt superheat tests were schedule in the future

  2. An Experimental Study on the Dynamics of a Single Droplet Vapor Explosion

    Energy Technology Data Exchange (ETDEWEB)

    Concilio Hansson, Roberta

    2010-07-01

    correlation between the coolant temperature and the molten droplet deformation/prefragmentation during the first bubble dynamics cycle. The SHARP observations followed by further analysis leads to a hypothesis about a novel phenomenon called pre-conditioning , according to which dynamics of the first bubble-dynamics cycle and the ability of the melt drop to deform/pre-fragment dictate the subsequent explosivity of the so-triggered droplet. The effect of non-condensable gases on the perceived mechanisms was investigated on the MISTEE-NCG test campaign, in which a considerable amount of non-condensable gases (NCG) are present in the film that enfolds the molten droplet. The SHARP images for the MISTEE-NCG tests were analyzed and special attention was given to the morphology (aspect ratio) and dynamics of the air/ vapor bubble, as well as the melt drop preconditioning and interaction energetics. Analysis showed two main aspects when compared to the MISTEE test series (without entrapped air). First, the investigation showed that the melt preconditioning still strongly depends on the coolant subcooling. Second, in respect to the energetics, the tests consistently showed a reduced conversion ratio compared to that of the MISTEE test series. The effect of the melt material in the steam explosion triggerability was also summoned, since it would in principle directly implicate the melt preconditioning. Since a number of the thermo-physical properties of the material would influence the triggering process, we focused on the material properties by using the same dioxide material with difference concentrations, i.e. eutectic and non-eutectic. Unfortunately, due to the high melt superheat the possible differences were not perceived. Thus, in addition to other materials, lower melt superheat tests were schedule in the future

  3. Parametric resonance in acoustically levitated water drops

    International Nuclear Information System (INIS)

    Shen, C.L.; Xie, W.J.; Wei, B.

    2010-01-01

    Liquid drops can be suspended in air with acoustic levitation method. When the sound pressure is periodically modulated, the levitated drop is usually forced into an axisymmetric oscillation. However, a transition from axisymmetric oscillation into sectorial oscillation occurs when the modulation frequency approaches some specific values. The frequency of the sectorial oscillation is almost exactly half of the modulation frequency. It is demonstrated that this transition is induced by the parametric resonance of levitated drop. The natural frequency of sectorial oscillation is found to decrease with the increase of drop distortion extent.

  4. Parametric resonance in acoustically levitated water drops

    Energy Technology Data Exchange (ETDEWEB)

    Shen, C.L.; Xie, W.J. [Department of Applied Physics, Northwestern Polytechnical University, Xi' an 710072 (China); Wei, B., E-mail: bbwei@nwpu.edu.c [Department of Applied Physics, Northwestern Polytechnical University, Xi' an 710072 (China)

    2010-05-10

    Liquid drops can be suspended in air with acoustic levitation method. When the sound pressure is periodically modulated, the levitated drop is usually forced into an axisymmetric oscillation. However, a transition from axisymmetric oscillation into sectorial oscillation occurs when the modulation frequency approaches some specific values. The frequency of the sectorial oscillation is almost exactly half of the modulation frequency. It is demonstrated that this transition is induced by the parametric resonance of levitated drop. The natural frequency of sectorial oscillation is found to decrease with the increase of drop distortion extent.

  5. Nonlinear dynamics of drops and bubbles and chaotic phenomena

    Science.gov (United States)

    Trinh, Eugene H.; Leal, L. G.; Feng, Z. C.; Holt, R. G.

    1994-01-01

    Nonlinear phenomena associated with the dynamics of free drops and bubbles are investigated analytically, numerically and experimentally. Although newly developed levitation and measurement techniques have been implemented, the full experimental validation of theoretical predictions has been hindered by interfering artifacts associated with levitation in the Earth gravitational field. The low gravity environment of orbital space flight has been shown to provide a more quiescent environment which can be utilized to better match the idealized theoretical conditions. The research effort described in this paper is a closely coupled collaboration between predictive and guiding theoretical activities and a unique experimental program involving the ultrasonic and electrostatic levitation of single droplets and bubbles. The goal is to develop and to validate methods based on nonlinear dynamics for the understanding of the large amplitude oscillatory response of single drops and bubbles to both isotropic and asymmetric pressure stimuli. The first specific area on interest has been the resonant coupling between volume and shape oscillatory modes isolated gas or vapor bubbles in a liquid host. The result of multiple time-scale asymptotic treatment, combined with domain perturbation and bifurcation methods, has been the prediction of resonant and near-resonant coupling between volume and shape modes leading to stable as well as chaotic oscillations. Experimental investigations of the large amplitude shape oscillation modes of centimeter-size single bubbles trapped in water at 1 G and under reduced hydrostatic pressure, have suggested the possibility of a low gravity experiment to study the direct coupling between these low frequency shape modes and the volume pulsation, sound-radiating mode. The second subject of interest has involved numerical modeling, using the boundary integral method, of the large amplitude shape oscillations of charged and uncharged drops in the presence

  6. Vapor Pressure Data Analysis and Statistics

    Science.gov (United States)

    2016-12-01

    near 8, 2000, and 200, respectively. The A (or a) value is directly related to vapor pressure and will be greater for high vapor pressure materials...1, (10) where n is the number of data points, Yi is the natural logarithm of the i th experimental vapor pressure value, and Xi is the...VAPOR PRESSURE DATA ANALYSIS AND STATISTICS ECBC-TR-1422 Ann Brozena RESEARCH AND TECHNOLOGY DIRECTORATE

  7. Deformed liquid marbles: Freezing drop oscillations with powders

    KAUST Repository

    Marston, Jeremy; Zhu, Y.; Vakarelski, Ivan Uriev; Thoroddsen, Sigurdur T

    2012-01-01

    In this work we show that when a liquid drop impacts onto a fine-grained hydrophobic powder, the final form of the drop can be very different from the spherical form with which it impacts. In all cases, the drop rebounds due to the hydrophobic nature of the powder. However, we find that above a critical impact speed, the drop undergoes a permanent deformation to a highly non-spherical shape with a near-complete coverage of powder, which then freezes the drop oscillations during rebound. © 2012 Elsevier B.V.

  8. Deformed liquid marbles: Freezing drop oscillations with powders

    KAUST Repository

    Marston, Jeremy

    2012-09-01

    In this work we show that when a liquid drop impacts onto a fine-grained hydrophobic powder, the final form of the drop can be very different from the spherical form with which it impacts. In all cases, the drop rebounds due to the hydrophobic nature of the powder. However, we find that above a critical impact speed, the drop undergoes a permanent deformation to a highly non-spherical shape with a near-complete coverage of powder, which then freezes the drop oscillations during rebound. © 2012 Elsevier B.V.

  9. Crystallization and preliminary X-ray analysis of Streptococcus mutans dextran glucosidase

    Energy Technology Data Exchange (ETDEWEB)

    Saburi, Wataru; Hondoh, Hironori, E-mail: hondoh@abs.agr.hokudai.ac.jp [Research Faculty of Agriculture, Hokkaido University, Sapporo, Hokkaido 060-8589 (Japan); Unno, Hideaki [Faculty of Engineering, Nagasaki University, Bunkyo-machi, Nagasaki 852-8521 (Japan); Okuyama, Masayuki; Mori, Haruhide [Research Faculty of Agriculture, Hokkaido University, Sapporo, Hokkaido 060-8589 (Japan); Nakada, Toshitaka [Faculty of Science and Engineering, Ritsumeikan University, Kusatsu, Shiga 525-8577 (Japan); Matsuura, Yoshiki [Institute for Protein Research, Osaka University, Suita, Osaka 565-0871 (Japan); Kimura, Atsuo [Research Faculty of Agriculture, Hokkaido University, Sapporo, Hokkaido 060-8589 (Japan)

    2007-09-01

    Dextran glucosidase from S. mutans was crystallized using the hanging-drop vapour-diffusion method. The crystals diffracted to 2.2 Å resolution. Dextran glucosidase from Streptococcus mutans is an exo-hydrolase that acts on the nonreducing terminal α-1,6-glucosidic linkage of oligosaccharides and dextran with a high degree of transglucosylation. Based on amino-acid sequence similarity, this enzyme is classified into glycoside hydrolase family 13. Recombinant dextran glucosidase was purified and crystallized by the hanging-drop vapour-diffusion technique using polyethylene glycol 6000 as a precipitant. The crystals belong to the orthorhombic space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 72.72, b = 86.47, c = 104.30 Å. A native data set was collected to 2.2 Å resolution from a single crystal.

  10. Crystallization and preliminary X-ray analysis of Streptococcus mutans dextran glucosidase

    International Nuclear Information System (INIS)

    Saburi, Wataru; Hondoh, Hironori; Unno, Hideaki; Okuyama, Masayuki; Mori, Haruhide; Nakada, Toshitaka; Matsuura, Yoshiki; Kimura, Atsuo

    2007-01-01

    Dextran glucosidase from S. mutans was crystallized using the hanging-drop vapour-diffusion method. The crystals diffracted to 2.2 Å resolution. Dextran glucosidase from Streptococcus mutans is an exo-hydrolase that acts on the nonreducing terminal α-1,6-glucosidic linkage of oligosaccharides and dextran with a high degree of transglucosylation. Based on amino-acid sequence similarity, this enzyme is classified into glycoside hydrolase family 13. Recombinant dextran glucosidase was purified and crystallized by the hanging-drop vapour-diffusion technique using polyethylene glycol 6000 as a precipitant. The crystals belong to the orthorhombic space group P2 1 2 1 2 1 , with unit-cell parameters a = 72.72, b = 86.47, c = 104.30 Å. A native data set was collected to 2.2 Å resolution from a single crystal

  11. Crystallization and preliminary X-ray characterization of a PaaX-like protein from Sulfolobus solfataricus P2

    International Nuclear Information System (INIS)

    Cao, Yi; Lou, Zhiyong; Sun, Yuna; Xue, Fei; Feng, Changzeng; Gong, Xiaocui; Yang, Dongmei; Bartlam, Mark; Meng, Zhaohui; Zhang, Keqin

    2009-01-01

    In this study, the PaaX-like protein from the hyperthermophilic archaeon Sulfolobus solfataricus P2 was successfully crystallized by the hanging-drop vapour-diffusion method using ammonium sulfate as a precipitant. PaaX is a global regulator of the phenylacetyl-coenzyme A catabolon that adjusts the expression of different operons to that of the paa-encoded central pathway. In this study, the PaaX-like protein from the hyperthermophilic archaeon Sulfolobus solfataricus P2 was successfully crystallized by the hanging-drop vapour-diffusion method using ammonium sulfate as a precipitant. Diffraction data were obtained to a resolution of 3.0 Å using synchrotron radiation at the Photon Factory. The crystal belonged to space group P321, with unit-cell parameters a = 86.4, b = 86.4, c = 105.5 Å

  12. Cloning, expression, purification, crystallization and preliminary X-ray studies of a pyridoxine 5′-phosphate oxidase from Mycobacterium smegmatis

    International Nuclear Information System (INIS)

    Jackson, Colin J.; Taylor, Matthew C.; Tattersall, David B.; French, Nigel G.; Carr, Paul D.; Ollis, David L.; Russell, Robyn J.; Oakeshott, John G.

    2008-01-01

    Good-quality crystals of selenomethionine-substituted Msmeg-3380 were obtained by the hanging-drop vapour-diffusion technique and diffracted to 1.2 Å using synchrotron radiation. Pyridoxine 5′-phosphate oxidases (PNPOxs) are known to catalyse the terminal step in pyridoxal 5′-phosphate biosynthesis in a flavin mononucleotide-dependent manner in humans and Escherichia coli. Recent reports of a putative PNPOx from Mycobacterium tuberculosis, Rv1155, suggest that the cofactor or catalytic mechanism may differ in Mycobacterium species. To investigate this, a putative PNPOx from M. smegmatis, Msmeg-3380, has been cloned. This enzyme has been recombinantly expressed in E. coli and purified to homogeneity. Good-quality crystals of selenomethionine-substituted Msmeg-3380 were obtained by the hanging-drop vapour-diffusion technique and diffracted to 1.2 Å using synchrotron radiation

  13. Cloning, expression, purification, crystallization and preliminary X-ray studies of a pyridoxine 5′-phosphate oxidase from Mycobacterium smegmatis

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, Colin J., E-mail: colin.jackson@csiro.au; Taylor, Matthew C.; Tattersall, David B.; French, Nigel G. [CSIRO Entomology, Black Mountain, ACT 2601 (Australia); Carr, Paul D.; Ollis, David L. [Research School of Chemistry, Australian National University, ACT 0200 (Australia); Russell, Robyn J.; Oakeshott, John G. [CSIRO Entomology, Black Mountain, ACT 2601 (Australia)

    2008-05-01

    Good-quality crystals of selenomethionine-substituted Msmeg-3380 were obtained by the hanging-drop vapour-diffusion technique and diffracted to 1.2 Å using synchrotron radiation. Pyridoxine 5′-phosphate oxidases (PNPOxs) are known to catalyse the terminal step in pyridoxal 5′-phosphate biosynthesis in a flavin mononucleotide-dependent manner in humans and Escherichia coli. Recent reports of a putative PNPOx from Mycobacterium tuberculosis, Rv1155, suggest that the cofactor or catalytic mechanism may differ in Mycobacterium species. To investigate this, a putative PNPOx from M. smegmatis, Msmeg-3380, has been cloned. This enzyme has been recombinantly expressed in E. coli and purified to homogeneity. Good-quality crystals of selenomethionine-substituted Msmeg-3380 were obtained by the hanging-drop vapour-diffusion technique and diffracted to 1.2 Å using synchrotron radiation.

  14. Levitation of a drop over a film flow

    Science.gov (United States)

    Sreenivas, K. R.; de, P. K.; Arakeri, Jaywant H.

    1999-02-01

    A vertical jet of water impinging on a horizontal surface produces a radial film flow followed by a circular hydraulic jump. We report a phenomenon where fairly large (1 ml) drops of liquid levitate just upstream of the jump on a thin air layer between the drop and the film flow. We explain the phenomenon using lubrication theory. Bearing action both in the air film and the water film seems to be necessary to support large drops. Horizontal support is given to the drop by the hydraulic jump. A variety of drop shapes is observed depending on the volume of the drop and liquid properties. We show that interaction of the forces due to gravity, surface tension, viscosity and inertia produces these various shapes.

  15. A Simple Experiment for Determining Vapor Pressure and Enthalpy of Vaporization of Water.

    Science.gov (United States)

    Levinson, Gerald S.

    1982-01-01

    Laboratory procedures, calculations, and sample results are described for a freshman chemistry experiment in which the Clausius-Clapeyron equation is introduced as a means of describing the variation of vapor pressure with temperature and for determining enthalpy of vaporization. (Author/SK)

  16. 46 CFR 160.035-12 - Additional preapproval tests required for F.R.P. lifeboats.

    Science.gov (United States)

    2010-10-01

    ... that when hanging freely the gunwale on one side of the boat is approximately 2 inches from a... no damage which would render the boat unserviceable. (4) Drop test. The boat shall be loaded with...

  17. Improvements to vapor generators

    International Nuclear Information System (INIS)

    Keller, Arthur; Monroe, Neil.

    1976-01-01

    A supporting system is proposed for vapor generators of the 'supported' type. Said supporting system is intended to compensate the disparities of thermal expansion due to the differences in the vertical dimensions of the tubes in the walls of the combustion chamber and their collectors compared to that of the balloon tanks and the connecting tube clusters of vaporization, the first one being longer than the second ones. Said system makes it possible to build said combustion chamber higher than the balloon tanks and the tube clusters of vaporization. The capacity of steam production is thus enhanced [fr

  18. Drop Test Results of CRDM under Seismic Loads

    International Nuclear Information System (INIS)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Kim, Gyeong-Ho; Sun, Jong-Oh; Huh, Hyung

    2016-01-01

    This paper describes the test results to demonstrate the drop performance of CRDM under seismic loads. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the drop performance under seismic loads such as operating basis earthquake (OBE) and safe shutdown earthquake (SSE). Especially, the CAR drop times are important data for the safety analysis. confirm the drop performance under seismic loads. The delay of drop time at Rig no. 2 due to seismic loads is greater than that at Rig no. 3. The total pure drop times under seismic loads are estimated as 1.169 and 1.855, respectively

  19. Drop Test Results of CRDM under Seismic Loads

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Myoung-Hwan; Cho, Yeong-Garp; Kim, Gyeong-Ho; Sun, Jong-Oh; Huh, Hyung [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    This paper describes the test results to demonstrate the drop performance of CRDM under seismic loads. The top-mounted CRDM driven by the stepping motor for Jordan Research and Training Reactor (JRTR) has been developed in KAERI. The CRDM for JRTR has been optimized by the design improvement based on that of the HANARO. It is necessary to verify the drop performance under seismic loads such as operating basis earthquake (OBE) and safe shutdown earthquake (SSE). Especially, the CAR drop times are important data for the safety analysis. confirm the drop performance under seismic loads. The delay of drop time at Rig no. 2 due to seismic loads is greater than that at Rig no. 3. The total pure drop times under seismic loads are estimated as 1.169 and 1.855, respectively.

  20. Impact of granular drops

    KAUST Repository

    Marston, J. O.

    2013-07-15

    We investigate the spreading and splashing of granular drops during impact with a solid target. The granular drops are formed from roughly spherical balls of sand mixed with water, which is used as a binder to hold the ball together during free-fall. We measure the instantaneous spread diameter for different impact speeds and find that the normalized spread diameter d/D grows as (tV/D)1/2. The speeds of the grains ejected during the “splash” are measured and they rarely exceed twice that of the impact speed.

  1. Impact of granular drops

    KAUST Repository

    Marston, J. O.; Mansoor, Mohammad M.; Thoroddsen, Sigurdur T

    2013-01-01

    We investigate the spreading and splashing of granular drops during impact with a solid target. The granular drops are formed from roughly spherical balls of sand mixed with water, which is used as a binder to hold the ball together during free-fall. We measure the instantaneous spread diameter for different impact speeds and find that the normalized spread diameter d/D grows as (tV/D)1/2. The speeds of the grains ejected during the “splash” are measured and they rarely exceed twice that of the impact speed.

  2. Structural analysis of hanging wall and footwall blocks within the Río Guanajibo fold-and-thrust belt in Southwest Puerto Rico

    Science.gov (United States)

    Laó-Dávila, Daniel A.; Llerandi-Román, Pablo A.

    2017-01-01

    The Río Guanajibo fold-and-thrust belt (RGFT), composed of Cretaceous serpentinite and volcano-sedimentary rocks, represents the deformation front of a contractional event in SW Puerto Rico during the Paleogene. Previous studies inferred structural and stratigraphic relationships from poorly exposed outcrops. New road cuts exposed the Yauco (YF) and El Rayo Formations (ERF) providing insights on the deformation of the hanging wall and footwall. We described the nature and orientation of faults and folds and analyzed the kinematic indicators to characterize the deformation. The YF occurs in the hanging wall and shows a sequence of folded, medium-bedded mudstone and thinly bedded shale and sandstone. Major folds strike NW-SE and are gentle with steeply inclined axial planes and sub-horizontal fold axes. Minor folds are open with moderately inclined axial planes and gently to moderately inclined SE-plunging fold axes. NW-SE striking reverse and thrust faults cut layers and show movement to the SW. Steep left-lateral faults strike NW-SE and NE-SW, and smaller right-lateral strike-slip faults strike NNE-SSW. At the footwall, the ERF consists of bioclastic limestone and polymictic orthoconglomerates and paraconglomerates. Reverse and strike-slip faults cut along lithological contacts. Results suggest that the hanging wall and footwall accommodated strain along preexisting weaknesses, which are dependent on lithology and sedimentary structures. The kinematic analysis suggests that shortening in the NE-SW direction was partitioned between folding and interlayer shortening, accommodated by flexural slip, and reverse and left-lateral faults that resulted from contraction. The RGFT represents the Paleogene back arc deformation of a bivergent thrust system.

  3. Thermogravimetric measurements of liquid vapor pressure

    International Nuclear Information System (INIS)

    Rong Yunhong; Gregson, Christopher M.; Parker, Alan

    2012-01-01

    Highlights: ► Rapid determination of vapor pressure by TGA. ► Demonstration of limitations of currently available approaches in literature. ► New model for vapor pressure assessment of small size samples in TGA. ► New model accounts for vapor diffusion and sample geometry and measures vapor pressure normally within 10%. - Abstract: A method was developed using thermo-gravimetric analysis (TGA) to determine the vapor pressure of volatile liquids. This is achieved by measuring the rate of evaporation (mass loss) of a pure liquid contained within a cylindrical pan. The influence of factors like sample geometry and vapor diffusion on evaporation rate are discussed. The measurement can be performed across a wide range of temperature yielding reasonable results up to 10 kPa. This approach may be useful as a rapid and automatable method for measuring the volatility of flavor and fragrance raw materials.

  4. Petroleum Vapor - Field Technical

    Science.gov (United States)

    The screening approach being developed by EPA OUST to evaluate petroleum vapor intrusion (PVI) requires information that has not be routinely collected in the past at vapor intrusion sites. What is the best way to collect this data? What are the relevant data quality issues and ...

  5. A Numerical Investigation of Vapor Intrusion — the Dynamic Response of Contaminant Vapors to Rainfall Events

    Science.gov (United States)

    Shen, Rui; Pennell, Kelly G.; Suuberg, Eric M.

    2013-01-01

    The U.S. government and various agencies have published guidelines for field investigation of vapor intrusion, most of which suggest soil gas sampling as an integral part of the investigation. Contaminant soil gas data are often relatively more stable than indoor air vapor concentration measurements, but meteorological conditions might influence soil gas values. Although a few field and numerical studies have considered some temporal effects on soil gas vapor transport, a full explanation of the contaminant vapor concentration response to rainfall events is not available. This manuscript seeks to demonstrate the effects on soil vapor transport during and after different rainfall events, by applying a coupled numerical model of fluid flow and vapor transport. Both a single rainfall event and seasonal rainfall events were modeled. For the single rainfall event models, the vapor response process could be divided into three steps: namely, infiltration, water redistribution, and establishment of a water lens atop the groundwater source. In the infiltration step, rainfall intensity was found to determine the speed of the wetting front and wash-out effect on the vapor. The passage of the wetting front led to an increase of the vapor concentration in both the infiltration and water redistribution steps and this effect is noted at soil probes located 1 m below the ground surface. When the mixing of groundwater with infiltrated water was not allowed, a clean water lens accumulated above the groundwater source and led to a capping effect which can reduce diffusion rates of contaminant from the source. Seasonal rainfall with short time intervals involved superposition of the individual rainfall events. This modeling results indicated that for relatively deeper soil that the infiltration wetting front could not flood, the effects were damped out in less than a month after rain; while in the long term (years), possible formation of a water lens played a larger role in

  6. The lithium vapor box divertor

    International Nuclear Information System (INIS)

    Goldston, R J; Schwartz, J; Myers, R

    2016-01-01

    It has long been recognized that volumetric dissipation of the plasma heat flux from a fusion power system is preferable to its localized impingement on a material surface. Volumetric dissipation mitigates both the anticipated very high heat flux and intense particle-induced damage due to sputtering. Recent projections to a tokamak demonstration power plant suggest an immense upstream parallel heat flux, of order 20 GW m −2 , implying that fully detached operation may be a requirement for the success of fusion power. Building on pioneering work on the use of lithium by Nagayama et al and by Ono et al as well as earlier work on the gas box divertor by Watkins and Rebut, we present here a concept for a lithium vapor box divertor, in which lithium vapor extracts momentum and energy from a fusion-power-plant divertor plasma, using fully volumetric processes. At the high powers and pressures that are projected this requires a high density of lithium vapor, which must be isolated from the main plasma in order to avoid lithium build-up on the chamber walls or in the plasma. Isolation is achieved through a powerful multi-box differential pumping scheme available only for condensable vapors. The preliminary box-wise calculations are encouraging, but much more work is required to demonstrate the practical viability of this scheme, taking into account at least 2D plasma and vapor flows within and between the vapor boxes and out of the vapor boxes to the main plasma. (paper)

  7. Vapor pressures and enthalpies of vaporization of a series of the linear aliphatic aldehydes

    Czech Academy of Sciences Publication Activity Database

    Verevkin, S. P.; Krasnykh, E. L.; Vasiltsova, T. V.; Koutek, Bohumír; Doubský, Jan; Heintz, A.

    2003-01-01

    Roč. 206, - (2003), s. 331-339 ISSN 0378-3812 Institutional research plan: CEZ:AV0Z4055905 Keywords : aldehydes * vapor pressure * enthalpy of vaporization Subject RIV: CC - Organic Chemistry Impact factor: 1.165, year: 2003

  8. Investigation of the condensing vapor bubble behavior through CFD simulation

    International Nuclear Information System (INIS)

    Sablania, Sidharth; Verma, Akash; Goyal, P.; Dutta, Anu; Singh, R.K.

    2013-09-01

    In nuclear systems the sub-cooled boiling flow is an important problem due to the behavior of condensing vapor bubble which has a large effect on the heat transfer characteristics as well as pressure drops and flow instability. The sub-cooled boiling flows become very complex and dynamic phenomena by the vapor bubble-water interaction. This happens due to the boiling/condensation, break-up, and coalescence of the bubble and needs to be addressed for characterizing the above mentioned flow parameters. There have been many researches to analyze the behavior of bubble experimentally and analytically. However, it is very difficult to get complete information about the behavior of bubble because of ever changing interface between vapor and water phase due to bubble condensation/evaporation Therefore, it is necessary to carry out a CFD simulation for better understanding the complex phenomenon of the bubble behavior. The present work focuses on the simulation of condensing bubble in subcooled boiling flow using (Volume of Fluid) VOF method in the CFD code CFD-ACE+. In order to simulate the heat and mass transfer through the bubble interface, CFD modeling for the bubble condensation was developed by modeling the source terms in the governing equations of VOF model using the User-Defined Function (UDF) in CFD-ACE+ code. The effect of condensation on bubble behavior was analyzed by comparing the behavior of condensing bubble with that of adiabatic bubble. It was observed that the behavior of condensing bubble was different from that of non condensing bubble in respect of bubble shape, diameter, velocity etc. The results obtained from the present simulation in terms of various parameters such as bubble velocity, interfacial area and bubble volume agreed well with the reported experimental results verified with FLUENT code in available literature. Hence, this CFD-ACE+ simulation of single bubble condensation will be a useful computational fluid dynamics tool for analyzing the

  9. Vapor pressures and enthalpies of vaporization of a series of γ and δ-lactones by correlation gas chromatography

    International Nuclear Information System (INIS)

    Kozlovskiy, Mikhail; Gobble, Chase; Chickos, James

    2014-01-01

    Highlights: • The vaporization enthalpies of γ-octanolactone, γ- and δ-undecanolactone and γ and δ-dodecanolactone are reported. • Equations for predicting the vapor pressures over the temperature range T = (298.15 to 350) K are provided. • Vaporization enthalpies are compared to predicted values. - Abstract: The vaporization enthalpies of γ-octanolactone, γ- and δ-undecanolactone and γ and δ-dodecanolactone used commercially as flavor ingredients are reported as are their vapor pressures over the temperature range T = (298.15 to 350) K. Vaporization enthalpies at T = 298.15 K of: (66.0 ± 3.9), (79.4 ± 4.4), (80.1 ± 4.5), (83.9 ± 4.6), and (84.61 ± 4.7) kJ · mol −1 and vapor pressures also at T = 298.15 K of: (2.8 ± 0.9), (0.12 ± 0.05), (0.09 ± 0.04), (0.04 ± 0.02), and (0.03 ± 0.02) Pa, respectively, have been evaluated by correlation gas chromatography experiments. The vaporization enthalpies of the lactones studied are reproduced within ±0.5 kJ · mol −1 using a group additivity scheme reported previously for γ- and δ-lactones. The vaporization enthalpies of the γ- and δ-lactones are compared to a similar series of ω-lactones

  10. Thyrotoxicosis Presenting as Unilateral Drop Foot.

    Science.gov (United States)

    Hara, Kenju; Miyata, Hajime; Motegi, Takahide; Shibano, Ken; Ishiguro, Hideaki

    2017-01-01

    Neuromuscular disorders associated with hyperthyroidism have several variations in their clinical phenotype, such as ophthalmopathy, periodic paralysis, and thyrotoxic myopathy. We herein report an unusual case of thyrotoxic myopathy presenting as unilateral drop foot. Histopathological examinations of the left tibialis anterior muscle showed marked variation in the fiber size, mild inflammatory cell infiltration, and necrotic and regenerated muscle fibers with predominantly type 1 fiber atrophy. Medical treatment with propylthiouracil resulted in complete improvement of the left drop foot. This case expands the phenotype of thyrotoxicosis and suggests that thyrotoxicosis be considered as a possible cause of unilateral drop foot.

  11. Bubble and Drop Nonlinear Dynamics (BDND)

    Science.gov (United States)

    Trinh, E. H.; Leal, L. Gary; Thomas, D. A.; Crouch, R. K.

    1998-01-01

    Free drops and bubbles are weakly nonlinear mechanical systems that are relatively simple to characterize experimentally in 1-G as well as in microgravity. The understanding of the details of their motion contributes to the fundamental study of nonlinear phenomena and to the measurement of the thermophysical properties of freely levitated melts. The goal of this Glovebox-based experimental investigation is the low-gravity assessment of the capabilities of a modular apparatus based on ultrasonic resonators and on the pseudo- extinction optical method. The required experimental task is the accurate measurements of the large-amplitude dynamics of free drops and bubbles in the absence of large biasing influences such as gravity and levitation fields. A single-axis levitator used for the positioning of drops in air, and an ultrasonic water-filled resonator for the trapping of air bubbles have been evaluated in low-gravity and in 1-G. The basic feasibility of drop positioning and shape oscillations measurements has been verified by using a laptop-interfaced automated data acquisition and the optical extinction technique. The major purpose of the investigation was to identify the salient technical issues associated with the development of a full-scale Microgravity experiment on single drop and bubble dynamics.

  12. Drop Testing Representative Multi-Canister Overpacks

    Energy Technology Data Exchange (ETDEWEB)

    Snow, Spencer D. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Morton, Dana K. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-06-01

    The objective of the work reported herein was to determine the ability of the Multi- Canister Overpack (MCO) canister design to maintain its containment boundary after an accidental drop event. Two test MCO canisters were assembled at Hanford, prepared for testing at the Idaho National Engineering and Environmental Laboratory (INEEL), drop tested at Sandia National Laboratories, and evaluated back at the INEEL. In addition to the actual testing efforts, finite element plastic analysis techniques were used to make both pre-test and post-test predictions of the test MCOs structural deformations. The completed effort has demonstrated that the canister design is capable of maintaining a 50 psig pressure boundary after drop testing. Based on helium leak testing methods, one test MCO was determined to have a leakage rate not greater than 1x10-5 std cc/sec (prior internal helium presence prevented a more rigorous test) and the remaining test MCO had a measured leakage rate less than 1x10-7 std cc/sec (i.e., a leaktight containment) after the drop test. The effort has also demonstrated the capability of finite element methods using plastic analysis techniques to accurately predict the structural deformations of canisters subjected to an accidental drop event.

  13. Lithium vapor trapping at a high-temperature lithium PFC divertor target

    Science.gov (United States)

    Jaworski, Michael; Abrams, T.; Goldston, R. J.; Kaita, R.; Stotler, D. P.; de Temmerman, G.; Scholten, J.; van den Berg, M. A.; van der Meiden, H. J.

    2014-10-01

    Liquid lithium has been proposed as a novel plasma-facing material for NSTX-U and next-step fusion devices but questions remain on the ultimate temperature limits of such a PFC during plasma bombardment. Lithium targets were exposed to high-flux plasma bombardment in the Magnum-PSI experimental device resulting in a temperature ramp from room-temperature to above 1200°C. A stable lithium vapor cloud was found to form directly in front of the target and persist to temperature above 1000°C. Consideration of mass and momentum balance in the pre-sheath region of an attached plasma indicates an increase in the magnitude of the pre-sheath potential drop with the inclusion of ionization sources as well as the inclusion of momentum loss terms. The low energy of lithium emission from a surface measured in previous experiments (Contract DE-AC02-09CH11466.

  14. Spent Nuclear Fuel (SNF) Bounding Drop Support Calculations

    International Nuclear Information System (INIS)

    CHENAULT, D.M.

    1999-01-01

    This report evaluates different drop heights, concrete and other impact media to which the transport package and/or the MCO is dropped. A prediction method is derived for estimating the resultant impact factor for determining the bounding drop case for the SNF Project

  15. A study on vapor explosions

    International Nuclear Information System (INIS)

    Takagi, N.; Shoji, M.

    1979-01-01

    An experimental study was carried out for vapor explosions of molten tin falling in water. For various initial metal temperatures and subcooling of water, transient pressure of the explosions, relative frequency of the explosions and the position where the explosions occur were measured in detail. The influence of ambient pressure was also investigated. From the results, it was concluded that the vapor explosion is closely related to the collapse of a vapor film around the molten metal. (author)

  16. A Hanged From the Past: Medical Consideration on the Judas Iscariot Fresco-Chapelle Notre-Dame-des-Fontaines, La Brigue (15th Century).

    Science.gov (United States)

    Gaeta, Raffaele; Fornaciari, Antonio

    2016-09-01

    The medieval chapel of Notre Dame-des-Fontaines (Our Lady of the Fountains), in the French Maritime Alps, is entirely covered by the fresco cycle of the Passion (15th century) that depicts the last days of Jesus from the Last Supper to the Resurrection. Under a small window, there is the brutal representation of the suicide of Judas Iscariot, hanging from a tree, with the abdomen quartered from which his soul, represented by a small man, is kidnapped by a devil. The author, Giovanni Canavesio, represented the traitor's death with very detailed anatomical structures, differently thus from other paintings of the same subject; it is therefore possible to assume that the artist had become familiar with the human anatomy. In particular, the realism of the hanged man's posture, neck bent in an unnatural way, allows us to hypothesize that it probably comes from direct observation of the executions of capital punishment, not infrequently imposed by the public authorities in low medieval Italy.

  17. Physical model for vaporization

    OpenAIRE

    Garai, Jozsef

    2006-01-01

    Based on two assumptions, the surface layer is flexible, and the internal energy of the latent heat of vaporization is completely utilized by the atoms for overcoming on the surface resistance of the liquid, the enthalpy of vaporization was calculated for 45 elements. The theoretical values were tested against experiments with positive result.

  18. Drop-out from a psychodynamic group psychotherapy outpatient unit.

    Science.gov (United States)

    Jensen, Hans Henrik; Mortensen, Erik Lykke; Lotz, Martin

    2014-11-01

    BACKGROUND. Drop-out from psychotherapy is common and represents a considerable problem in clinical practice and research. Aim. To explore pre-treatment predictors of early and late drop-out from psychodynamic group therapy in a public outpatient unit for non-psychotic disorders in Denmark. Methods. Naturalistic design including 329 patients, the majority with mood, neurotic and personality disorders referred to 39-session group therapy. Predictors were socio-demographic and clinical variables, self-reported symptoms (Symptom Check List-90-Revised) and personality style (Millon Clinical Multiaxial Inventory-II). Drop-out was classified into early and late premature termination excluding patients who dropped out for external reasons. Results. Drop-out comprised 20.6% (68 patients) of the sample. Logistic regression revealed social functioning, vocational training, alcohol problems and antisocial behavior to be related to drop-out. However, early drop-outs had prominent agoraphobic symptoms, lower interpersonal sensitivity and compulsive personality features, and late drop-outs cognitive and somatic anxiety symptoms and antisocial personality features. Clinical and psychological variables accounted for the major part of variance in predictions of drop-out, which ranged from 15.6% to 19.5% (Nagelkerke Pseudo R-Square). Conclusion. Social functioning was consistently associated with drop-out, but personality characteristics and anxiety symptoms differentiated between early and late drop-out. Failure to discriminate between stages of premature termination may explain some of the inconsistencies in the drop-out literature. Clinical implications. Before selection of patients to time-limited psychodynamic groups, self-reported symptoms should be thoroughly considered. Patients with agoraphobic symptoms should be offered alternative treatment. Awareness of and motivation to work with interpersonal issues may be essential for compliance with group therapy.

  19. Reducing Variability in Stress Drop with Root-Mean Acceleration

    Science.gov (United States)

    Crempien, J.; Archuleta, R. J.

    2012-12-01

    Stress drop is a fundamental property of the earthquake source. For a given tectonic region stress drop is assumed to be constant allowing for the scaling of earthquake spectra. However, the variability of the stress drop, either for worldwide catalogs or regional catalogs, is quite large. The variability around the median value is on the order of 1.5 in log10 units. One question that continues to pervade the analysis of stress drop is whether this variability is an inherent characteristic of the Earth or is an artifact of the determination of stress drop via the use of the spectral analysis. It is simple to see that the stress drop determined by seismic moment times corner frequency cubed that errors in the corner frequency will strongly influence the variability in the stress drop. To avoid this strong dependence on corner frequency cubed, we have examined the determination of stress drop based on the approach proposed by Hanks (1979), namely using the root-mean-square acceleration. The stress drop determined using rms acceleration may be advantageous because the stress drop is only affected by the square root of the corner frequency. To test this approach we have determined stress drops for the 2000 Tottori earthquake and its aftershocks. We use both the classic method of fitting to a spectrum as well as using rms acceleration. For a preliminary analysis of eight aftershocks and the mainshock we find that the variability in stress drop is reduced by about a factor of two. This approach needs more careful analysis of more events, which will be shown at the meeting.

  20. Why Do Students Drop Advanced Mathematics?

    Science.gov (United States)

    Horn, Ilana

    2004-01-01

    Students, especially black, Latino and Native American youth and students of low socio-economic status drop out of advanced mathematics. Teachers must coordinate their expectations, their knowledge of students and their teaching practices in order to stop struggling students from dropping out of advanced math classes.

  1. Delayed frost growth on jumping-drop superhydrophobic surfaces.

    Science.gov (United States)

    Boreyko, Jonathan B; Collier, C Patrick

    2013-02-26

    Self-propelled jumping drops are continuously removed from a condensing superhydrophobic surface to enable a micrometric steady-state drop size. Here, we report that subcooled condensate on a chilled superhydrophobic surface are able to repeatedly jump off the surface before heterogeneous ice nucleation occurs. Frost still forms on the superhydrophobic surface due to ice nucleation at neighboring edge defects, which eventually spreads over the entire surface via an interdrop frost wave. The growth of this interdrop frost front is shown to be up to 3 times slower on the superhydrophobic surface compared to a control hydrophobic surface, due to the jumping-drop effect dynamically minimizing the average drop size and surface coverage of the condensate. A simple scaling model is developed to relate the success and speed of interdrop ice bridging to the drop size distribution. While other reports of condensation frosting on superhydrophobic surfaces have focused exclusively on liquid-solid ice nucleation for isolated drops, these findings reveal that the growth of frost is an interdrop phenomenon that is strongly coupled to the wettability and drop size distribution of the surface. A jumping-drop superhydrophobic condenser minimized frost formation relative to a conventional dropwise condenser in two respects: preventing heterogeneous ice nucleation by continuously removing subcooled condensate, and delaying frost growth by limiting the success of interdrop ice bridge formation.

  2. Free drop impact analysis of shipping cask

    International Nuclear Information System (INIS)

    Pfeiffer, P.A.; Kennedy, J.M.

    1989-01-01

    The WHAMS-2D and WHAMS-3D codes were used to analyze the dynamic response of the RAS/TREAT shielded shipping cask subjected to transient leadings for the purpose of assessing potential damage to the various components that comprise the the cask. The paper describes how these codes can be used to provide and intermediate level of detail between full three-dimensional finite element calculations and hand calculations which are cost effective for design purposes. Three free drops were adressed: (1) a thirty foot axial drop on either end; (2) a thirty foot oblique angle drop with the cask having several different orientations from the vertical with impact on the cask corner; and (3) a thirty foot side drop with simultaneous impact on the lifting trunnion and the bottom end. Results are presented for two models of the side and oblique angle drops; one model includes only the mass of the lapped sleeves of depleted uranium (DU) while the other includes the mass and stiffness of the DU. The results of the end drop analyses are given for models with and without imperfections in the cask. Comparison of the analysis to hand calculations and simplified analyses are given. (orig.)

  3. Electrowetting-on-dielectrics for manipulation of oil drops and gas bubbles in aqueous-shell compound drops.

    Science.gov (United States)

    Li, Jiang; Wang, Yixuan; Chen, Haosheng; Wan, Jiandi

    2014-11-21

    We present the manipulation of oil, organic and gaseous chemicals by electrowetting-on-dielectric (EWOD) technology using aqueous-shell compound drops. We demonstrate that the transport and coalescence of viscous oil drops, the reaction of bromine with styrene in benzene solution, and the reaction of red blood cells with carbon monoxide bubbles can be accomplished using this method.

  4. Vaporization of irradiated droplets

    International Nuclear Information System (INIS)

    Armstrong, R.L.; O'Rourke, P.J.; Zardecki, A.

    1986-01-01

    The vaporization of a spherically symmetric liquid droplet subject to a high-intensity laser flux is investigated on the basis of a hydrodynamic description of the system composed of the vapor and ambient gas. In the limit of the convective vaporization, the boundary conditions at the fluid--gas interface are formulated by using the notion of a Knudsen layer in which translational equilibrium is established. This leads to approximate jump conditions at the interface. For homogeneous energy deposition, the hydrodynamic equations are solved numerically with the aid of the CON1D computer code (''CON1D: A computer program for calculating spherically symmetric droplet combustion,'' Los Alamos National Laboratory Report No. LA-10269-MS, December, 1984), based on the implict continuous--fluid Eulerian (ICE) [J. Comput. Phys. 8, 197 (1971)] and arbitrary Lagrangian--Eulerian (ALE) [J. Comput. Phys. 14, 1227 (1974)] numerical mehtods. The solutions exhibit the existence of two shock waves propagating in opposite directions with respect to the contact discontinuity surface that separates the ambient gas and vapor

  5. Crystallization and preliminary X-ray analysis of an enantioselective halohydrin dehalogenase from Agrobacterium radiobacter AD1

    NARCIS (Netherlands)

    Jong, René M. de; Rozeboom, Henriëtte J.; Kalk, Kor H.; Tang, Lixia; Janssen, Dick B.; Dijkstra, Bauke W.

    2002-01-01

    Halohydrin dehalogenases are key enzymes in the bacterial degradation of vicinal halopropanols and structurally related nematocides. Crystals of the enantioselective halohydrin dehalogenase HheC from Agrobacterium radiobacter AD1 have been obtained at room temperature from hanging-drop

  6. Crystallization and preliminary X-ray analysis of an enantioselective halohydrin dehalogenase from Agrobacterium radiobacter AD1

    NARCIS (Netherlands)

    de Jong, RM; Rozeboom, HJ; Kalk, KH; Tang, Lixia; Janssen, DB; Dijkstra, BW

    Halohydrin dehalogenases are key enzymes in the bacterial degradation of vicinal halopropanols and structurally related nematocides. Crystals of the enantioselective halohydrin dehalogenase HheC from Agrobacterium radiobacter AD1 have been obtained at room temperature from hanging-drop

  7. Non-equilibrium phenomena near vapor-liquid interfaces

    CERN Document Server

    Kryukov, Alexei; Puzina, Yulia

    2013-01-01

    This book presents information on the development of a non-equilibrium approach to the study of heat and mass transfer problems using vapor-liquid interfaces, and demonstrates its application to a broad range of problems. In the process, the following peculiarities become apparent: 1. At vapor condensation on the interface from gas-vapor mixture, non-condensable components can lock up the interface surface and condensation stops completely. 2. At the evolution of vapor film on the heater in superfluid helium (He-II), the boiling mass flux density from the vapor-liquid interface is effectively zero at the macroscopic scale. 3. In problems concerning the motion of He-II bridges inside capillaries filled by vapor, in the presence of axial heat flux the He-II bridge cannot move from the heater as would a traditional liquid, but in the opposite direction instead. Thus the heater attracts the superfluid helium bridge. 4. The shape of liquid-vapor interface at film boiling on the axis-symmetric heaters immersed in l...

  8. Effect of impact angle on vaporization

    Science.gov (United States)

    Schultz, Peter H.

    1996-09-01

    Impacts into easily vaporized targets such as dry ice and carbonates generate a rapidly expanding vapor cloud. Laboratory experiments performed in a tenuous atmosphere allow deriving the internal energy of this cloud through well-established and tested theoretical descriptions. A second set of experiments under near-vacuum conditions provides a second measure of energy as the internal energy converts to kinetic energy of expansion. The resulting data allow deriving the vaporized mass as a function of impact angle and velocity. Although peak shock pressures decrease with decreasing impact angle (referenced to horizontal), the amount of impact-generated vapor is found to increase and is derived from the upper surface. Moreover, the temperature of the vapor cloud appears to decrease with decreasing angle. These unexpected results are proposed to reflect the increasing roles of shear heating and downrange hypervelocity ricochet impacts created during oblique impacts. The shallow provenance, low temperature, and trajectory of such vapor have implications for larger-scale events, including enhancement of atmospheric and biospheric stress by oblique terrestrial impacts and impact recycling of the early atmosphere of Mars.

  9. A Citizen's Guide to Vapor Intrusion Mitigation

    Science.gov (United States)

    This guide describes how vapor intrusion is the movement of chemical vapors from contaminated soil and groundwater into nearby buildings.Vapors primarily enter through openings in the building foundation or basement walls.

  10. Condensation of vapor bubble in subcooled pool

    Science.gov (United States)

    Horiuchi, K.; Koiwa, Y.; Kaneko, T.; Ueno, I.

    2017-02-01

    We focus on condensation process of vapor bubble exposed to a pooled liquid of subcooled conditions. Two different geometries are employed in the present research; one is the evaporation on the heated surface, that is, subcooled pool boiling, and the other the injection of vapor into the subcooled pool. The test fluid is water, and all series of the experiments are conducted under the atmospheric pressure condition. The degree of subcooling is ranged from 10 to 40 K. Through the boiling experiment, unique phenomenon known as microbubble emission boiling (MEB) is introduced; this phenomenon realizes heat flux about 10 times higher than the critical heat flux. Condensation of the vapor bubble is the key phenomenon to supply ambient cold liquid to the heated surface. In order to understand the condensing process in the MEB, we prepare vapor in the vapor generator instead of the evaporation on the heated surface, and inject the vapor to expose the vapor bubble to the subcooled liquid. Special attention is paid to the dynamics of the vapor bubble detected by the high-speed video camera, and on the enhancement of the heat transfer due to the variation of interface area driven by the condensation.

  11. Studying the field induced breakup of acoustically levitated drops

    Science.gov (United States)

    Warschat, C.; Riedel, J.

    2017-10-01

    Coulomb fission of charged droplets (The terms drop and droplet are often used synonymous. Throughout this manuscript, to avoid confusion, the terms drop and droplet will be used for liquid spheres with radii in the millimeter range and the micrometer range, respectively. In our experiments, the first correspond to the parent drop while the latter describes the ejected progeny droplets.) is a well-studied natural phenomenon. Controlled droplet fission is already successfully employed in several technological applications. Still, since the occurring surface rupture relies on the exact understanding and description of the liquid gas boundary, some details are still under debate. Most empirical systematic studies observe falling micrometer droplets passing through the electric field inside a plate capacitor. This approach, although easily applicable and reliable, limits the experimental degrees of freedom regarding the observable time and the maximum size of the drops and can only be performed in consecutive individual observations of different subsequent drops. Here we present a novel setup to study the field induced breakup of acoustically levitated drops. The design does not bear any restrictions towards the temporal window of observation, and allows handling of drops of a tunable radius ranging from 10 μm to several millimeters and a real-time monitoring of one single drop. Our comprehensive study includes a time resolved visual inspection, laser shadowgraphy, laser induced fluorescence imaging, and ambient mass spectrometric interrogation of the nascent Taylor cone. The results shown for a millimeter sized drop, previously inaccessible for Coulomb fission experiments, are mostly comparable with previous results for smaller drops. The major difference is the time scale and the threshold potential of the drop rupture. Both values, however, resemble theoretically extrapolations to the larger radius. The technique allows for a systematic study of breakup behavior of

  12. Motion of a drop driven by substrate vibrations

    Science.gov (United States)

    Brunet, P.; Eggers, J.; Deegan, R. D.

    2009-01-01

    We report an experimental study of liquid drops moving against gravity, when placed on a vertically vibrating inclined plate, which is partially wet by the drop. Frequency of vibrations ranges from 30 to 200 Hz, and above a threshold in vibration acceleration, drops experience an upward motion. We attribute this surprising motion to the deformations of the drop, as a consequence of an up/down symmetry-breaking induced by the presence of the substrate. We relate the direction of motion to contact angle measurements.

  13. The new Drop Tower catapult system

    Science.gov (United States)

    von Kampen, Peter; Kaczmarczik, Ulrich; Rath, Hans J.

    2006-07-01

    The Center of Applied Space Technology and Microgravity (ZARM) was founded in 1985 as an institute of the University Bremen, which focuses on research on gravitational and space-related phenomena. In 1988, the construction of the "Drop Tower" began. Since then, the eye-catching tower with a height of 146 m and its characteristic glass roof has become the emblem of the technology centre in Bremen. The Drop Tower Bremen provides a facility for experiments under conditions of weightlessness. Items are considered weightless, when they are in "free fall", i.e. moving without propulsion within the gravity field of the earth. The height of the tower limits the simple "free fall" experiment period to max. 4.74 s. With the inauguration of the catapult system in December 2004, the ZARM is entering a new dimension. This world novelty will meet scientists' demands of extending the experiment period up to 9.5 s. Since turning the first sod on May 3rd, 1988, the later installation of the catapult system has been taken into account by building the necessary chamber under the tower. The catapult system is located in a chamber 10 m below the base of the tower. This chamber is almost completely occupied by 12 huge pressure tanks. These tanks are placed around the elongation of the vacuum chamber of the drop tube. In its centre there is the pneumatic piston that accelerates the drop capsule by the pressure difference between the vacuum inside the drop tube and the pressure inside the tanks. The acceleration level is adjusted by means of a servo hydraulic breaking system controlling the piston velocity. After only a quarter of a second the drop capsule achieves its lift-off speed of 175 km/h. With this exact speed, the capsule will rise up to the top of the tower and afterwards fall down again into the deceleration unit which has been moved under the drop tube in the meantime. The scientific advantages of the doubled experiment time are obvious: during almost 10 s of high

  14. Crystallization of ornithine acetyltransferase from yeast by counter-diffusion and preliminary X-ray study

    Energy Technology Data Exchange (ETDEWEB)

    Maes, Dominique, E-mail: dominique.maes@vub.ac.be; Crabeel, Marjolaine [Laboratorium voor Ultrastructuur, Vrije Universiteit Brussel (VUB) and Vlaams Interuniversitair Instituut voor Biotechnologie (VIB), Pleinlaan 2, B-1050 Brussels (Belgium); Van de Weerdt, Cécile; Martial, Joseph [Laboratoire de Biologie Moléculaire et de Génie Génétique, Université de Liège, Allée de la Chimie 3, B-4000 Liège (Belgium); Peeters, Eveline; Charlier, Daniël [Erfelijkheidsleer en Microbiologie, Vrije Universiteit Brussel (VUB), Pleinlaan 2, B-1050 Brussels (Belgium); Decanniere, Klaas; Vanhee, Celine; Wyns, Lode; Zegers, Ingrid [Laboratorium voor Ultrastructuur, Vrije Universiteit Brussel (VUB) and Vlaams Interuniversitair Instituut voor Biotechnologie (VIB), Pleinlaan 2, B-1050 Brussels (Belgium)

    2006-12-01

    A study on the crystallization of ornithine acetyltransferase from yeast, catalysing the fifth step in microbial arginine synthesis, is presented. The use of the counter-diffusion technique removes the disorder present in one dimension in crystals grown by either batch or hanging-drop techniques. A study is presented on the crystallization of ornithine acetyltransferase from yeast, which catalyzes the fifth step in microbial arginine synthesis. The use of the counter-diffusion technique removes the disorder present in one dimension in crystals grown by either the batch or hanging-drop techniques. This makes the difference between useless crystals and crystals that allow successful determination of the structure of the protein. The crystals belong to space group P4, with unit-cell parameters a = b = 66.98, c = 427.09 Å, and a data set was collected to 2.76 Å.

  15. Heterologous expression, purification, crystallization and preliminary X-ray analysis of raucaffricine glucosidase, a plant enzyme specifically involved in Rauvolfia alkaloid biosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Ruppert, Martin [Department of Pharmaceutical Biology, Institute of Pharmacy, Johannes Gutenberg-University Mainz, Staudinger Weg 5, D-55099 Mainz (Germany); Panjikar, Santosh [European Molecular Biology Laboratory Hamburg, Outstation Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22603 Hamburg (Germany); Barleben, Leif [Department of Pharmaceutical Biology, Institute of Pharmacy, Johannes Gutenberg-University Mainz, Staudinger Weg 5, D-55099 Mainz (Germany); Stöckigt, Joachim [Department of Pharmaceutical Biology, Institute of Pharmacy, Johannes Gutenberg-University Mainz, Staudinger Weg 5, D-55099 Mainz (Germany); College of Pharmaceutical Sciences, Zhejiang University, 353 Yan An Road, 310031 Hangzhou (China)

    2006-03-01

    Raucaffricine glucosidase, an enzyme involved in the biosynthesis of monoterpenoid indole alkaloids in the plant Rauvolfia serpentina, was crystallized by the hanging-drop vapour-diffusion method using PEG4000 as precipitant. The crystals diffract to 2.3 Å resolution and belong to space group I222. Raucaffricine glucosidase (RG) is an enzyme that is specifically involved in the biosynthesis of indole alkaloids from the plant Rauvolfia serpentina. After heterologous expression in Escherichia coli cells, crystals of RG were obtained by the hanging-drop vapour-diffusion technique at 293 K with 0.3 M ammonium sulfate, 0.1 M sodium acetate pH 4.6 buffer and 11% PEG 4000 as precipitant. Crystals belong to space group I222 and diffract to 2.30 Å, with unit-cell parameters a = 102.8, b = 127.3, c = 215.8 Å.

  16. Heterologous expression, purification, crystallization and preliminary X-ray analysis of raucaffricine glucosidase, a plant enzyme specifically involved in Rauvolfia alkaloid biosynthesis

    International Nuclear Information System (INIS)

    Ruppert, Martin; Panjikar, Santosh; Barleben, Leif; Stöckigt, Joachim

    2006-01-01

    Raucaffricine glucosidase, an enzyme involved in the biosynthesis of monoterpenoid indole alkaloids in the plant Rauvolfia serpentina, was crystallized by the hanging-drop vapour-diffusion method using PEG4000 as precipitant. The crystals diffract to 2.3 Å resolution and belong to space group I222. Raucaffricine glucosidase (RG) is an enzyme that is specifically involved in the biosynthesis of indole alkaloids from the plant Rauvolfia serpentina. After heterologous expression in Escherichia coli cells, crystals of RG were obtained by the hanging-drop vapour-diffusion technique at 293 K with 0.3 M ammonium sulfate, 0.1 M sodium acetate pH 4.6 buffer and 11% PEG 4000 as precipitant. Crystals belong to space group I222 and diffract to 2.30 Å, with unit-cell parameters a = 102.8, b = 127.3, c = 215.8 Å

  17. Crystallization and preliminary crystallographic analysis of recombinant immunoglobulin G-binding protein from Streptococcus suis

    Energy Technology Data Exchange (ETDEWEB)

    Khan, Abdul Hamid; Chu, Fuliang; Feng, Youjun; Zhang, Qinagmin [Center for Molecular Immunology, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101 (China); Qi, Jianxun [Institute of Physics, Chinese Academy of Sciences, Beijing 100080 (China); Gao, George Fu, E-mail: gaof@im.ac.cn [Center for Molecular Immunology, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101 (China)

    2008-08-01

    Crystallization of recombinant IgG-binding protein expressed in Escherichia coli using the hanging-drop vapour-diffusion method is described. The crystals belonged to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 38.98, b = 43.94, c = 78.17 Å. Streptococcus suis, an important zoonotic pathogen, expresses immunoglobulin G-binding protein, which is thought to be helpful to the organism in eluding the host defence system. Recombinant IgG-binding protein expressed in Escherichia coli has been crystallized using the hanging-drop vapour-diffusion method. The crystals belonged to space group P2{sub 1}2{sub 1}2{sub 1}, with unit-cell parameters a = 38.98, b = 43.94, c = 78.17 Å and one molecule in the asymmetric unit. Diffraction data were collected to 2.60 Å resolution.

  18. Collapsing criteria for vapor film around solid spheres as a fundamental stage leading to vapor explosion

    Energy Technology Data Exchange (ETDEWEB)

    Freud, Roy [Nuclear Research Center - Negev, Beer-Sheva (Israel)], E-mail: freud@bgu.ac.il; Harari, Ronen [Nuclear Research Center - Negev, Beer-Sheva (Israel); Sher, Eran [Pearlstone Center for Aeronautical Studies, Department of Mechanical Engineering, Ben-Gurion University, Beer-Sheva (Israel)

    2009-04-15

    Following a partial fuel-melting accident, a Fuel-Coolant Interaction (FCI) can result with the fragmentation of the melt into tiny droplets. A vapor film is then formed between the melt fragments and the coolant, while preventing a contact between them. Triggering, propagation and expansion typically follow the premixing stage. In the triggering stage, vapor film collapse around one or several of the fragments occurs. This collapse can be the result of fragments cooling, a sort of mechanical force, or by any other means. When the vapor film collapses and the coolant re-establishes contact with the dry surface of the hot melt, it may lead to a very rapid and rather violent boiling. In the propagation stage the shock wave front leads to stripping of the films surrounding adjacent droplets which enhance the fragmentation and the process escalates. During this process a large quantity of liquid vaporizes and its expansion can result in destructive mechanical damage to the surrounding structures. This multiphase thermal detonation in which high pressure shock wave is formed is regarded as 'vapor explosion'. The film boiling and its possible collapse is a fundamental stage leading to vapor explosion. If the interaction of the melt and the coolant does not result in a film boiling, no explosion occurs. Many studies have been devoted to determine the minimum temperature and heat flux that is required to maintain a film boiling. The present experimental study examines the minimum temperature that is required to maintain a film boiling around metal spheres immersed into a liquid (subcooled distilled water) reservoir. In order to simulate fuel fragments that are small in dimension and has mirror-like surface, small spheres coated with anti-oxidation layer were used. The heat flux from the spheres was calculated from the sphere's temperature profiles and the sphere's properties. The vapor film collapse was associated with a sharp rise of the heat flux

  19. Collapsing criteria for vapor film around solid spheres as a fundamental stage leading to vapor explosion

    International Nuclear Information System (INIS)

    Freud, Roy; Harari, Ronen; Sher, Eran

    2009-01-01

    Following a partial fuel-melting accident, a Fuel-Coolant Interaction (FCI) can result with the fragmentation of the melt into tiny droplets. A vapor film is then formed between the melt fragments and the coolant, while preventing a contact between them. Triggering, propagation and expansion typically follow the premixing stage. In the triggering stage, vapor film collapse around one or several of the fragments occurs. This collapse can be the result of fragments cooling, a sort of mechanical force, or by any other means. When the vapor film collapses and the coolant re-establishes contact with the dry surface of the hot melt, it may lead to a very rapid and rather violent boiling. In the propagation stage the shock wave front leads to stripping of the films surrounding adjacent droplets which enhance the fragmentation and the process escalates. During this process a large quantity of liquid vaporizes and its expansion can result in destructive mechanical damage to the surrounding structures. This multiphase thermal detonation in which high pressure shock wave is formed is regarded as 'vapor explosion'. The film boiling and its possible collapse is a fundamental stage leading to vapor explosion. If the interaction of the melt and the coolant does not result in a film boiling, no explosion occurs. Many studies have been devoted to determine the minimum temperature and heat flux that is required to maintain a film boiling. The present experimental study examines the minimum temperature that is required to maintain a film boiling around metal spheres immersed into a liquid (subcooled distilled water) reservoir. In order to simulate fuel fragments that are small in dimension and has mirror-like surface, small spheres coated with anti-oxidation layer were used. The heat flux from the spheres was calculated from the sphere's temperature profiles and the sphere's properties. The vapor film collapse was associated with a sharp rise of the heat flux during the cooling

  20. Theory of magnetostriction of electron-hole drops in Ge

    International Nuclear Information System (INIS)

    Markiewicz, R.S.

    1978-01-01

    A large mass of electron-hole liquid (γ drop) formed in a strain-induced potential well in Ge is known to distort its shape significantly in a magnetic field B > or approx. = 1 kG. It is shown in this paper that the shape change can be understood in detail as due to a ''recombination current'' of electron-hole pairs needed to replace those pairs which recombine in the drop volume. The Lorentz force deflects this current and produces a macroscopic dipole current loop inside the drop. The drop then changes shape to minimize its total energy, including magnetic, strain, and surface energies. While the drop usually flattens along the field direction, both para- and diamagnetic effects (elongated drops) are found to be possible, depending on excitation conditions, in accord with experiment. Similar effects are predicted to occur in small drops in unstrained Ge. This paper presents a magnetohydrodynamic theory of the magnetostriction which takes into account density variations which occur in the strain well and in high magnetic fields. A simpler theory is given for the special case in which the drop may be considered incompressible (small drops and moderate fields). Effects of carrier mass anisotropy and fluid viscosity are taken into consideration

  1. Ground Motion Prediction Equations Empowered by Stress Drop Measurement

    Science.gov (United States)

    Miyake, H.; Oth, A.

    2015-12-01

    Significant variation of stress drop is a crucial issue for ground motion prediction equations and probabilistic seismic hazard assessment, since only a few ground motion prediction equations take into account stress drop. In addition to average and sigma studies of stress drop and ground motion prediction equations (e.g., Cotton et al., 2013; Baltay and Hanks, 2014), we explore 1-to-1 relationship for each earthquake between stress drop and between-event residual of a ground motion prediction equation. We used the stress drop dataset of Oth (2013) for Japanese crustal earthquakes ranging 0.1 to 100 MPa and K-NET/KiK-net ground motion dataset against for several ground motion prediction equations with volcanic front treatment. Between-event residuals for ground accelerations and velocities are generally coincident with stress drop, as investigated by seismic intensity measures of Oth et al. (2015). Moreover, we found faster attenuation of ground acceleration and velocities for large stress drop events for the similar fault distance range and focal depth. It may suggest an alternative parameterization of stress drop to control attenuation distance rate for ground motion prediction equations. We also investigate 1-to-1 relationship and sigma for regional/national-scale stress drop variation and current national-scale ground motion equations.

  2. Vapor deposition of tantalum and tantalum compounds

    International Nuclear Information System (INIS)

    Trkula, M.

    1996-01-01

    Tantalum, and many of its compounds, can be deposited as coatings with techniques ranging from pure, thermal chemical vapor deposition to pure physical vapor deposition. This review concentrates on chemical vapor deposition techniques. The paper takes a historical approach. The authors review classical, metal halide-based techniques and current techniques for tantalum chemical vapor deposition. The advantages and limitations of the techniques will be compared. The need for new lower temperature processes and hence new precursor chemicals will be examined and explained. In the last section, they add some speculation as to possible new, low-temperature precursors for tantalum chemical vapor deposition

  3. Pressure Drop of Chamfer on Spacer Grid Strap

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Euijae; Kim, Kanghoon; Kim, Kyounghong; Nahm, Keeyil [KEPCO Nuclear Fuel Co., Daejeon (Korea, Republic of)

    2014-05-15

    A swirl flow and cross flow are generated by the spacer grid with mixing vane that enhances the thermal performance and critical heat flux (CHF). The additional pressure drop makes it difficult to meet acceptance criteria for overall pressure drop in fuel assembly depending upon the pump capacity. The chamfer on the end of spacer grid strap is one solution to reduce additional pressure drop without any adverse effect on flow fields. In this research, the pressure drop tests for spacer grid with and without chamfer were carried out at the hydraulic test facility. The result can be applied to develop high performance nuclear fuel assemblies for Pressurized Water Reactor (PWR) plants. The pressure drop tests for 5x5 spacer grid with and without chamfer as well as 6x6 spacer grid with and without chamfer were carried out at the INFINIT test facility. The Reynolds number ranged about from 16000 to 75000. The sweep-up and sweep-down test showed that the direction of sweep did not affect the pressure drop. The chamfer on spacer grid strap reduced the pressure drop due to the decreased in ratio of inlet area to outlet area. The pressure loss coefficient for spacer grid with chamfer was by up to 13.8 % lower than that for spacer grid without chamfer. Hence, the chamfer on spacer grid strap was one of effective ways to reduce the pressure drop.

  4. Drop impact entrapment of bubble rings

    KAUST Repository

    Thoraval, M.-J.

    2013-04-29

    We use ultra-high-speed video imaging to look at the initial contact of a drop impacting on a liquid layer. We observe experimentally the vortex street and the bubble-ring entrapments predicted numerically, for high impact velocities, by Thoraval et al. (Phys. Rev. Lett., vol. 108, 2012, article 264506). These dynamics mainly occur within 50 -s after the first contact, requiring imaging at 1 million f.p.s. For a water drop impacting on a thin layer of water, the entrapment of isolated bubbles starts through azimuthal instability, which forms at low impact velocities, in the neck connecting the drop and pool. For Reynolds number Re above -12 000, up to 10 partial bubble rings have been observed at the base of the ejecta, starting when the contact is -20% of the drop size. More regular bubble rings are observed for a pool of ethanol or methanol. The video imaging shows rotation around some of these air cylinders, which can temporarily delay their breakup into micro-bubbles. The different refractive index in the pool liquid reveals the destabilization of the vortices and the formation of streamwise vortices and intricate vortex tangles. Fine-scale axisymmetry is thereby destroyed. We show also that the shape of the drop has a strong influence on these dynamics. 2013 Cambridge University Press.

  5. Evidence of a sewer vapor transport pathway at the USEPA vapor intrusion research duplex

    Science.gov (United States)

    The role of sewer lines as preferential pathways for vapor intrusion is poorly understood. Although the importance of sewer lines for volatile organic compound (VOC) transport has been documented at a small number of sites with vapor intrusion, sewer lines are not routinely sampl...

  6. Marangoni Flow Induced Evaporation Enhancement on Binary Sessile Drops.

    Science.gov (United States)

    Chen, Pin; Harmand, Souad; Ouenzerfi, Safouene; Schiffler, Jesse

    2017-06-15

    The evaporation processes of pure water, pure 1-butanol, and 5% 1-butanol aqueous solution drops on heated hydrophobic substrates are investigated to determine the effect of temperature on the drop evaporation behavior. The evolution of the parameters (contact angle, diameter, and volume) during evaporation measured using a drop shape analyzer and the infrared thermal mapping of the drop surface recorded by an infrared camera were used in investigating the evaporation process. The pure 1-butanol drop does not show any thermal instability at different substrate temperatures, while the convection cells created by the thermal Marangoni effect appear on the surface of the pure water drop from 50 °C. Because 1-butanol and water have different surface tensions, the infrared video of the 5% 1-butanol aqueous solution drop shows that the convection cells are generated by the solutal Marangoni effect at any substrate temperature. Furthermore, when the substrate temperature exceeds 50 °C, coexistence of the thermal and solutal Marangoni flows is observed. By analyzing the relation between the ratio of the evaporation rate of pure water and 1-butanol aqueous solution drops and the Marangoni number, a series of empirical equations for predicting the evaporation rates of pure water and 1-butanol aqueous solution drops at the initial time as well as the equations for the evaporation rate of 1-butanol aqueous solution drop before the depletion of alcohol are derived. The results of these equations correspond fairly well to the experimental data.

  7. Knudsen cell vaporization of rare earth nitrides: enthalpy of vaporization of HoN098

    International Nuclear Information System (INIS)

    Brown, R.C.; Clark, N.J.

    1975-01-01

    The enthalpy of vaporization of HoN 0 . 98 was measured by the weight-loss Knudsen cell technique using Motzfeldt-Whitman extrapolations to zero orifice area. A third-law enthalpy of vaporization of HoN 0 . 98 of 155.9 +- 5 kcal mole -1 was obtained compared to a second-law value of 162.0 +- 5 kcal mole -1 . Similar measurements on the nitrides of samarium, erbium, and ytterbium gave third-law enthalpies of vaporization of 126.8 +-- 5 kcal mole -1 ; 159.6 +- 5 kcal mole -1 , and 121.0 +- 5 kcal mole -1 , respectively. 7 tables

  8. Vapor pressures and vapor compositions in equilibrium with hypostoichiometric plutonium dioxide at high temperatures

    International Nuclear Information System (INIS)

    Green, D.W.; Fink, J.K.; Leibowitz, L.

    1982-01-01

    Vapor pressures and vapor compositions have been calculated for 1500 less than or equal to T less than or equal to 4000 0 K. Thermodynamic functions for the condensed phase and for each of the gaseous species were combined with an oxygen-potential model extended into the liquid region to obtain the partial pressures of O 2 , O, Pu, PuO and PuO 2 . The calculated oxygen pressures increase very rapidly as stoichiometry is approached. At least part of this increase is a consequence of the exclusion of Pu 6 + from the oxygen-potential model. No reliable method was found to estimate the importance of this ion. As a result of large oxygen potentials at high temperatures, extremely high total pressures that produced unreasonably high vapor densities were calculated. The highest temperature was therefore limited to 400 K, and the range of oxygen-to-metal ratios was limited to 1.994 to 1.70. These calculations show that vapor in equilibrium with hypostoichiometric plutonium dioxide is poorly approximated as PuO 2 for most of the temperture and composition range of interest. The vapor is much more oxygen-rich than the condensed phase. Implications for the (U,Pu)O/sub 2-x/ system are discussed

  9. Drop-out rate and drop-out reasons among promising Norwegian track and field athletes: a 25 year study

    OpenAIRE

    Enoksen, Eystein

    2011-01-01

    © Eystein Enoksen, 2011 The aim of the present study was to identify the total drop-out rate and drop-out reasons for a group of promising track and field athletes. 202 males and 98 females, aged 16 ±2 years, took part in this study. Questionnaires were administrated in 1975, 1983, and 1989. In-depth interviews were conducted in 1989 and in 2000. A chi-square test was administrated to test the difference between males and females dropping out and to test the most significant reasons influe...

  10. Vapor pressure measured with inflatable plastic bag

    Science.gov (United States)

    1965-01-01

    Deflated plastic bag in a vacuum chamber measures initial low vapor pressures of materials. The bag captures the test sample vapors and visual observation of the vapor-inflated bag under increasing external pressures yields pertinent data.

  11. Numerical and Experimental Study of an Ambient Air Vaporizer Coupled with a Compact Heat Exchanger

    Science.gov (United States)

    Kimura, Randon

    The University of Washington was tasked with designing a "21st century engine" that will make use of the thermal energy available in cryogenic gasses due to their coldness. There are currently large quantities of cryogenic gases stored throughout the U.S. at industrial facilities whereupon the regasification process, the potential for the fluid to do work is wasted. The engine proposed by the University of Washington will try to capture some of that wasted energy. One technical challenge that must be overcome during the regasification process is providing frost free operation. This thesis presents the numerical analysis and experimental testing of a passive heat exchange system that uses ambient vaporizers coupled with compact heat exchangers to provide frost free operation while minimizing pressure drop.

  12. Temperature dependences of saturated vapor pressure and the enthalpy of vaporization of n-pentyl esters of dicarboxylic acids

    Science.gov (United States)

    Portnova, S. V.; Krasnykh, E. L.; Levanova, S. V.

    2016-05-01

    The saturated vapor pressures and enthalpies of vaporization of n-pentyl esters of linear C2-C6 dicarboxylic acids are determined by the transpiration method in the temperature range of 309.2-361.2 K. The dependences of enthalpies of vaporization on the number of carbon atoms in the molecule and on the retention indices have been determined. The predictive capabilities of the existing calculation schemes for estimation of enthalpy of vaporization of the studied compounds have been analyzed.

  13. Vapor-droplet flow equations

    International Nuclear Information System (INIS)

    Crowe, C.T.

    1975-01-01

    General features of a vapor-droplet flow are discussed and the equations expressing the conservation of mass, momentum, and energy for the vapor, liquid, and mixture using the control volume approach are derived. The phenomenological laws describing the exchange of mass, momentum, and energy between phases are also reviewed. The results have application to development of water-dominated geothermal resources

  14. University Drop-Out: An Italian Experience

    Science.gov (United States)

    Belloc, Filippo; Maruotti, Antonello; Petrella, Lea

    2010-01-01

    University students' drop-out is a crucial issue for the universities' efficiency evaluation and funding. In this paper, we analyze the drop-out rate of the Economics and Business faculty of Sapienza University of Rome. We use administrative data on 9,725 undergraduates students enrolled in three-years bachelor programs from 2001 to 2007 and…

  15. Acoustic forcing of a liquid drop

    Science.gov (United States)

    Lyell, M. J.

    1992-01-01

    The development of systems such as acoustic levitation chambers will allow for the positioning and manipulation of material samples (drops) in a microgravity environment. This provides the capability for fundamental studies in droplet dynamics as well as containerless processing work. Such systems use acoustic radiation pressure forces to position or to further manipulate (e.g., oscillate) the sample. The primary objective was to determine the effect of a viscous acoustic field/tangential radiation pressure forcing on drop oscillations. To this end, the viscous acoustic field is determined. Modified (forced) hydrodynamic field equations which result from a consistent perturbation expansion scheme are solved. This is done in the separate cases of an unmodulated and a modulated acoustic field. The effect of the tangential radiation stress on the hydrodynamic field (drop oscillations) is found to manifest as a correction to the velocity field in a sublayer region near the drop/host interface. Moreover, the forcing due to the radiation pressure vector at the interface is modified by inclusion of tangential stresses.

  16. A Novel Technique for Laparoscopic Salvage of CAPD Catheter Malfunction and Migration: The Santosh-PGI Hanging Loop Technique

    Directory of Open Access Journals (Sweden)

    Santosh Kumar

    2015-01-01

    Full Text Available CAPD catheter malfunction is a common problem. Obstruction due to wrapping by appendices epiploicae of sigmoid colon has been rarely reported in literature. We report a case of CAPD catheter malfunction caused by catheter tip migration and obstruction by appendices epiploicae that was successfully managed by laparoscopic hanging loop technique. This case report highlights the ease with which epiplopexy can be performed and catheter tip migration can be prevented by this innovative laparoscopic procedure.

  17. What Good is Raman Water Vapor Lidar?

    Science.gov (United States)

    Whitman, David

    2011-01-01

    Raman lidar has been used to quantify water vapor in the atmosphere for various scientific studies including mesoscale meteorology and satellite validation. Now the international networks of NDACC and GRUAN have interest in using Raman water vapor lidar for detecting trends in atmospheric water vapor concentrations. What are the data needs for addressing these very different measurement challenges. We will review briefly the scientific needs for water vapor accuracy for each of these three applications and attempt to translate that into performance specifications for Raman lidar in an effort to address the question in the title of "What good is Raman water vapor Iidar."

  18. DROpS: an object of learning in computer simulation of discrete events

    Directory of Open Access Journals (Sweden)

    Hugo Alves Silva Ribeiro

    2015-09-01

    Full Text Available This work presents the “Realistic Dynamics Of Simulated Operations” (DROpS, the name given to the dynamics using the “dropper” device as an object of teaching and learning. The objective is to present alternatives for professors teaching content related to simulation of discrete events to graduate students in production engineering. The aim is to enable students to develop skills related to data collection, modeling, statistical analysis, and interpretation of results. This dynamic has been developed and applied to the students by placing them in a situation analogous to a real industry, where various concepts related to computer simulation were discussed, allowing the students to put these concepts into practice in an interactive manner, thus facilitating learning

  19. Crystallization and preliminary X-ray diffraction studies of the pneumococcal teichoic acid phosphorylcholine esterase Pce

    Energy Technology Data Exchange (ETDEWEB)

    Lagartera, Laura; González, Ana; Stelter, Meike; García, Pedro; Kahn, Richard; Menéndez, Margarita; Hermoso, Juan A., E-mail: xjuan@iqfr.csic.es

    2005-02-01

    The modular choline-binding protein Pce, the phosphorylcholine esterase from S. pneumoniae, has been crystallized by the hanging-drop vapour-diffusion method. A SAD data set from a derivative with a gadolinium complex has been collected to 2.7 Å resolution.

  20. Flow Vaporization of CO{sub 2} in Microchannel Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Pettersen, Jostein

    2002-07-01

    Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have shown a clear dominance of nucleate boiling even at very high mass flux. Heat transfer tests were conducted in a rig using a flat, extruded aluminium microchannel tube of 540 mm length with 25 channels of 0.81 mm diameter. The horizontal test tube was heated by a water jacket in order to get representative boundary conditions for air-to-refrigerant heat transfer (''fluid heating''). Constant heat flux conditions do not simulate these boundary conditions well, and may give unrealistic behaviour especially in relation to dryout and post-dryout heat transfer. Systematic tests at constant heat flux with single-phase CO{sub 2} flow on the inside generated data that were used in the derivation of a model for water-side beat transfer coefficient. A regression based on these data gave a calibrated equation for water-side heat transfer on the form NuNu(Re,Pr). This equation was then used in later experiments to subtract water-side thermal resistance from the measured overall resistance (1/UA), thereby finding the internal heat