Sample records for handheld snm monitors

  1. Standard guide to In-Plant performance evaluation of Hand-Held SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide is one of a series on the application and evaluation of special nuclear material (SNM) monitors. Other guides in the series are listed in Section 2, and the relationship of in-plant performance evaluation to other procedures described in the series is illustrated in Fig. 1. Hand-held SNM monitors are described in of Guide C1112, and performance criteria illustrating their capabilities can be found in Appendix X1. 1.2 The purpose of this guide to in-plant performance evaluation is to provide a comparatively rapid procedure to verify that a hand-held SNM monitor performs as expected for detecting SNM or alternative test sources or to disclose the need for repair. The procedure can be used as a routine operational evaluation or it can be used to verify performance after a monitor is calibrated. 1.3 In-plant performance evaluations are more comprehensive than daily functional tests. They take place less often, at intervals ranging from weekly to once every three months, and derive their result fr...

  2. New portable hand-held radiation instruments for measurements and monitoring

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-01-01

    Hand-held radiation monitors are often used to search pedestrians and motor vehicles for special nuclear material (SNM) as part of a physical protection plan for nuclear materials. Recently, the Los Alamos Advanced Nuclear Technology group has commercialized an improved hand-held monitor that can be used for both physical-protection monitoring and verification measurements in nuclear material control and waste management. The new monitoring instruments are smaller and lighter; operate much longer on a battery charge; are available with NaI(Tl) or neutron and gamma-ray sensitive plastic scintillation detectors; and are less expensive than other comparable instruments. They also have a second operating mode for making precise measurements over counting times as long as 99 s. This mode permits making basic verification measurements that may be needed before transporting nuclear material or waste outside protected areas. Improved verification measurements can be made with a second new hand-held instrument that has a stabilized detector and three separate gamma-ray energy windows to obtain spectral information for SNM quantity, enrichment, or material-type verification

  3. Applications guide to pedestrian SNM monitors

    Energy Technology Data Exchange (ETDEWEB)

    Fehlau, P.E.

    1986-02-01

    The applications guide introduces readers to the pedestrian special nuclear material (SNM) monitors that provide nuclear material control at DOE contractor facilities. It explains the principles of operation, the strong and weak points, and steps for calibration and maintenance of the monitors. Administrators and security specialists will find an overview of pedestrain monitor application and upkeep in Part 1 of the guide and a descriptive catalog of present-day monitors in Part 3. Technically oriented readers will be interested in the more detailed discussion of SNM monitoring physics and SNM monitor design principles found in Part 2. 18 refs., 33 figs., 9 tabs.

  4. Applications guide to pedestrian SNM monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1986-02-01

    The applications guide introduces readers to the pedestrian special nuclear material (SNM) monitors that provide nuclear material control at DOE contractor facilities. It explains the principles of operation, the strong and weak points, and steps for calibration and maintenance of the monitors. Administrators and security specialists will find an overview of pedestrain monitor application and upkeep in Part 1 of the guide and a descriptive catalog of present-day monitors in Part 3. Technically oriented readers will be interested in the more detailed discussion of SNM monitoring physics and SNM monitor design principles found in Part 2. 18 refs., 33 figs., 9 tabs

  5. An applications guide to vehicle SNM monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1987-03-01

    The applications guide introduces its readers to the vehicle special nuclear material (SNM) monitors that are becoming part of safeguards and security measures for nuclear material control at DOE facilities. Building on the foundation provided by an applications guide to pedestrian SNM monitors published in 1986 and a technical report on vehicle monitoring published in 1982, the guide provides an overview of vehicle monitoring in Part 1, a discussion of technical aspects of vehicle monitoring in Part 2, and a catalog of vehicle SNM monitors available to DOE facilities in Part 3. Vehicle monitor upkeep, calibration, testing, and performance are important topics in Part 1. The short technical discussion in Part 2 is devoted to new developments and unique features of vehicle monitors

  6. 1997 update for the applications guide to vehicle SNM monitors

    International Nuclear Information System (INIS)

    York, R.L.; Fehlau, P.E.

    1997-04-01

    Ten years have elapsed since the publication of the original applications guide to vehicle special nuclear material (SNM) monitors. During that interval, use of automatic vehicle monitors has become more commonplace, and formal procedures for monitor upkeep and evaluation have become available. New concepts for vehicle monitoring are being explored, as well. This update report reviews the basics of vehicle SNM monitoring, discusses what is new in vehicle SNM monitoring, and catalogs the vehicle SNM monitors that are commercial available

  7. Standard guide for in-plant performance evaluation of automatic pedestrian SNM monitors

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    1.1 This guide is affiliated with Guide C1112 on special nuclear material (SNM) monitors, Guide C1169 on laboratory performance evaluation, and Guide C1189 on calibrating pedestrian SNM monitors. This guide to in-plant performance evaluation is a comparatively rapid way to verify whether a pedestrian SNM monitor performs as expected for detecting SNM or SNM-like test sources. 1.1.1 In-plant performance evaluation should not be confused with the simple daily functional test recommended in Guide C1112. In-plant performance evaluation takes place less often than daily tests, usually at intervals ranging from weekly to once every three months. In-plant evaluations are also more extensive than daily tests and may examine both a monitor's nuisance alarm record and its detection sensitivity for a particular SNM or alternative test source. 1.1.2 In-plant performance evaluation also should not be confused with laboratory performance evaluation. In-plant evaluation is comparatively rapid, takes place in the monitor...

  8. Process instrument monitoring for SNM solution surveillance

    International Nuclear Information System (INIS)

    Armatys, C.M.; Johnson, C.E.; Wagner, E.P.

    1983-02-01

    A process monitoring computer system at the Idaho Chemical Processing Plant (ICPP) is being used to evaluate nuclear fuel reprocessing plant data for Safeguards surveillance capabilities. The computer system was installed to collect data from the existing plant instruments and to evaluate what safeguards assurances can be provided to complement conventional accountability and physical protection measures. Movements of solutions containing special nuclear material (SNM) can be observed, activities associated with accountancy measurements (mixing, sampling, and bulk measurement) can be confirmed, and long-term storage of SNM solutions can be monitored to ensure containment. Special precautions must be taken, both in system design and operation to ensure adequate coverage of essential measured parameters and interpretation of process data, which can be comprised by instrument malfunctions or failures, unreliable data collection, or process activities that deviate from readily identified procedures. Experience at ICPP and prior evaluations at the Tokai reprocessing plant show that the use of process data can provide assurances that accountability measurement procedures are followed and SNM solutions are properly contained and can help confirm that SNM controls are in effect within a facility

  9. Special nuclear material radiation monitors for the 1980's

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1985-01-01

    During the two decades that automatic gamma-radiation monitors have been applied to detecting special nuclear material (SNM), little attention has been devoted to how well the monitors perform in plant environments. Visits to 11 DOE facilities revealed poor information flow between developers, manufacturers, and maintainers of SNM radiation monitors. To help users achieve best performance from their monitors or select new ones, Los Alamos National Laboratory developed a hand-held monitor user's guide, calibration manuals for some commercial SNM pedestrian monitors, and an application guide for SNM pedestrian monitors. In addition, Los Alamos evaluated new commercial SNM monitors, considered whether to apply neutron detection to SNM monitoring, and investigated the problem of operating gamma-ray SNM monitors in variable plutonium gamma-radiation fields. As a result, the performance of existing SNM monitors will improve and alternative monitoring methods will become commerciallly available during the 1980s. 9 refs., 6 figs., 1 tab

  10. A portable, automatic SNM monitor for nuclear safeguards: Development, evaluation, and applications

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1993-09-01

    The portable SNM monitor is a lightweight, full-size, automatic monitor, suitable for temporary service (such as demonstrations or for use during maintenance) or as a permanent replacement for hand- held monitors. The authors based the monitor on the TSA Systems, Ltd., modular SNM monitor design and, through evaluation and improvement of the commercial modules, obtained adequate sensitivity in a single- cabinet monitor that is easily portable. Complete monitoring of pedestrians with a single detector cabinet is achieved by requiring the pedestrian to stand in front of the detectors and turn around through 360 deg while being observed by a security inspector. The monitor is available commercially as the TSA Systems Model PMD-701, and it is beginning to be used in both temporary and permanent applications

  11. Design of microprocessor data acquisition system for pedestrian portal SNM monitor

    International Nuclear Information System (INIS)

    Zhang Wenliang

    2003-01-01

    The paper introduces the hardware structure and composition of data acquisition system for pedestrian portal special nuclear material (SNM) monitor. The hardware and software of single chip microprocessor AT89C52, LCM, keyboard and serial communication interface software are also discussed. (authors)

  12. Hand-held personnel and vehicle monitors

    International Nuclear Information System (INIS)

    Kunz, W.E.; Chambers, W.H.; Henry, C.N.; France, S.W.; Millegan, D.R.; Hastings, R.D.; Worth, G.M.

    1976-05-01

    A light, rugged monitor has been developed for special nuclear materials (SNM) searches at material-access and protection-area exits. This monitor accepts gamma-ray pulses from a NaI(Tl) detector, integrates for a preset counting interval (typically 0.3 s), and produces an audible alarm whenever the counts in the interval exceed the trip level that is a preset multiple of the stored background count. Because the monitor is silent except when the alarm is operating, personnel with little special training can conduct more effective searches in a noisy and distracting environment than they can with conventional audible monitoring of individual radiation counts. The monitor is also more sensitive than conventional monitors that provide audible indication of the count rate

  13. New ICPP portal monitor

    International Nuclear Information System (INIS)

    Georgeson, M.A.; Nichols, C.E.

    1981-04-01

    A large area gas filled proportional-detector portal monitor mounted in a swinging door frame has been designed and developed at the Idaho Chemical Processing Plant (ICPP). This monitor extends the sensitivity and speed of personnel contamination detection to levels equal to or exceeding that obtained using hand-held portable survey techniques. The new monitor has state-of-the-art electronics which result in rapid response, and use statistical principles in the alarm logic to reduce or eliminate spurious alarms. In addition, the evaluation of this instrument indicates that it will detect small enough quantities of U-235 in shielded containers to meet current special nuclear materials (SNM) detection standards. Simultaneous detection of very low level contamination and small quantities of SNM results in a monitor particularly useful for nuclear installations

  14. Special Nuclear Material Portal Monitoring at the Nevada Test Site

    International Nuclear Information System (INIS)

    DeAnn Long; Michael Murphy

    2008-01-01

    Prior to April 2007, acceptance and performance testing of the various Special Nuclear Material (SNM) monitoring devices at the Nevada Test Site (NTS) was performed by the Radiological Health Instrumentation department. Calibration and performance testing on the PM-700 personnel portal monitor was performed, but there was no test program for the VM-250 vehicle portal monitor. The handheld SNM monitors, the TSA model 470B, were being calibrated annually, but there was no performance test program. In April of 2007, the Material Control and Accountability Manager volunteered to take over performance testing of all SNM portal monitors at NTS in order to strengthen the program and meet U.S. Department of Energy Order requirements. This paper will discuss the following activities associated with developing a performance testing program: changing the culture, learning the systems, developing and implementing procedures, troubleshooting and repair, validating the process, physical control of equipment, acquisition of new systems, and implementing the performance test program

  15. Special Nuclear Material Portal Monitoring at the Nevada Test Site

    International Nuclear Information System (INIS)

    Mike Murphy

    2008-01-01

    In the past, acceptance and performance testing of the various Special Nuclear Material (SNM) monitoring devices at the Nevada Test Site has been performed by the Radiological Health Instrumentation Department. Calibration and performance tests on the PM-700 personnel portal monitor were performed but there was no test program for the VM-250 vehicle portal monitor because it had never been put into service. The handheld SNM monitors, the TSA model 470B, were being calibrated annually, but there was no program in place to test them quarterly. In April of 2007, the Material Control and Accountability (MC and A) Manager at the time decided that the program needed to be strengthened and MC and A took over performance testing of all SNM portal monitoring equipment. This paper will discuss the following activities associated with creating a performance testing program: changing the culture, learning the systems, writing procedures, troubleshooting/repairing, validating the process, control of equipment, acquisition of new systems, and running the program

  16. SNM gamma-ray fingerprint monitor functional requirements and design specifications

    International Nuclear Information System (INIS)

    Bieber, A.M. Jr.; Kane, W.R.

    1994-07-01

    A number of DOE facilities need to perform confirmatory inventory measurements on items of special nuclear material (SNM). The DOE Office of Safeguards and Security (OSS) has tasked the Safeguards, Safety and Nonproliferation Division (SSN) of the Department of Advanced Technology at Brookhaven National Laboratory (BNL) to develop a high-resolution gamma-ray-spectroscopy-based instrument for performing confirmatory inventory measurements on such materials, a ''gamma-ray fingerprint monitor'' (GRFM). This document is a conceptual design for the SSN GRFM system. This conceptual design is based on previous experience with measurements of plutonium-bearing materials and comparison of gamma-ray spectrum features, not on actual tests of the procedures or hardware described. As a result, modifications may be necessary when actual prototype hardware and software are tested in realistic circumstances on actual materials of interest

  17. The TMI-2 SNM accountability program

    International Nuclear Information System (INIS)

    Schork, J.S.; Rogan, R.E.; Deininger, F.W.; Weaver, W.W.

    1988-01-01

    This paper describes the Special Nuclear Material (SNM) Accountability Program for Three Mile Isaland Unit 2. The TMI-2 SNM Accountability Program is uniquely designed to inventory and control the SNM borne by the fuel materials that were distributed throughout the Reactor Vessel and connected Reactor Coolant System piping as a result of the March, 1979 accident. The current knowledge of fuel (SNM) quantities and locations as a result of the TMI-2 accident is reviewed. The inventory and control of fuel debris canisters, core debris samples, water process filters, ion exchnagers and radioactive waste that contain SNM is discussed. In addition, the methods and techniques for performing the Post-Defueling Survey of residual SNM quantities at the end of defueling activities are described. The integration of the Waste Management (shipping), Defueling (packaging), Radiological Controls and Data Management and Analysis Departments support is addressed. Finally, the contractual transfer of TMI-2 fuel debris ownership from GPU Nuclear to the Department of Energy is reviewed

  18. A data communications systems for tamper-protected special nuclear materials (SNM) inventory management

    International Nuclear Information System (INIS)

    Hurkamp, A.C.

    1995-01-01

    The Department of Energy (D.O.E.) is responsible for the long term storage and protection of large quantities of Special Nuclear Material (SNM). This material is stored within individual containers located in vaults. Security measures are required to ensure that the SNM remains within the canisters where it is stored and that it is not disturbed in any manner. Conventional security and inventory techniques are manpower intensive and often require exposure to radiation hazards. The Purpose of this D.O.E sponsored project is to develop a cost effective system to monitor Special Nuclear Materials that, when fielded, would result in an extension of manual inventory cycles at a wide variety of SNM storage locations. The system consists of a computer, radio frequency interrogator, and individual miniaturized radio frequency transponders (tags) that are co-located with individual SNM containers. Each tag can perform SNM inventory, tamper alarm, and multiple sensor data transmission to the interrogator under the control of software designed by the user. SNM custodians can customize the system by their choice of packaging, software, and sensors. When implemented in accordance with current department of energy (D.O.E.) Policy on SNM inventory extension, the system has the potential to qualify for maximum extension times thus saving considerable resources through reduction of radiation exposure

  19. Continuous inventory in SNM storage facilities

    International Nuclear Information System (INIS)

    Chambers, W.H.

    1975-01-01

    Instrumentation and data processing techniques that provide inexpensive verification of material in storage were investigated. Transfers of special nuclear materials (SNM) into the storage area are accompanied by an automated verification of the container identity, weight, and the radiation signature of the contents. This information is computer-processed and stored for comparison at subsequent transfers and also provides the data base for record purposes. Physical movement of containers across the boundary of the storage area is presently accomplished by operating personnel in order to minimize expensive modifications to existing storage facilities. Personnel entering and leaving the storage area are uniquely identified and also through portal monitors capable of detecting small quantities of SNM. Once material is placed on the storage shelves, simple, low-cost container tagging and radiation sensors are activated. A portion of the prescribed gamma signature, obtained by duplicate shelf monitors during the transfer verification, is thus continuously checked against the stored identification data. Radiation detector design is severely constrained by the need to discriminate individual signatures in a high background area and the need for low unit costs. In operation any unauthorized change in signal is analyzed along with auxiliary data from surveillance sensors to activate the appropriate alarms. (auth))

  20. Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF

    Energy Technology Data Exchange (ETDEWEB)

    Aldrian, Alexia, E-mail: alexia.aldrian@unileoben.ac.at [Chair of Waste Processing Technology and Waste Management, Montanuniversitaet Leoben, Franz-Josef-Straße 18, 8700 Leoben (Austria); Ledersteger, Alfred, E-mail: a.ledersteger@saubermacher.at [Saubermacher Dienstleistungs AG, Hans-Roth-Straße 1, 8073 Feldkirchen bei Graz (Austria); Pomberger, Roland, E-mail: roland.pomberger@unileoben.ac.at [Chair of Waste Processing Technology and Waste Management, Montanuniversitaet Leoben, Franz-Josef-Straße 18, 8700 Leoben (Austria)

    2015-02-15

    Highlights: • Specification of an empirical factor for conversion from bromine to PBB and PBDE. • The handheld XRF device was validated for this particular application. • A very large number of over 4600 pieces of monitor housings was analysed. • The recyclable fraction mounts up to 85% for TV but only 53% of PC waste plastics. • A high percentage of pieces with bromine contents of over 50,000 ppm was obtained. - Abstract: This contribution is focused on the on-site determination of the bromine content in waste electrical and electronic equipment (WEEE), in particular waste plastics from television sets (TV) and personal computer monitors (PC) using a handheld X-ray fluorescence (XRF) device. The described approach allows the examination of samples in regards to the compliance with legal specifications for polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) directly after disassembling and facilitates the sorting out of plastics with high contents of brominated flame retardants (BFRs). In all, over 3000 pieces of black (TV) and 1600 pieces of grey (PC) plastic waste were analysed with handheld XRF technique for this study. Especially noticeable was the high percentage of pieces with a bromine content of over 50,000 ppm for TV (7%) and PC (39%) waste plastics. The applied method was validated by comparing the data of handheld XRF with results obtained by GC–MS. The results showed the expected and sufficiently accurate correlation between these two methods. It is shown that handheld XRF technique is an effective tool for fast monitoring of large volumes of WEEE plastics in regards to BFRs for on-site measurements.

  1. The role of SNM portal monitoring in the Russian MPC ampersand A program

    International Nuclear Information System (INIS)

    York, R.L.

    1997-01-01

    Controlling the movement of nuclear materials is still the most effective nonproliferation measure. Pedestrian and vehicle portal monitors have been an established tool for preventing the unauthorized movement of SNM across US nuclear facility boundaries for 15 years. Because the portals are reliable and easy to install, they are an efficient first step to improve the security at Russian nuclear facilities. The portals were first furnished to Russian facilities for testing and evaluation. After Russian technical experts gained experience with the operating parameters, the instruments were implemented at appropriate locations at each facility. This process has been executed at IPPE, VNIEF, VNIITF, RCC KI, and SKhK. The transfer of the portal monitoring technology to Russian institutes to promote the manufacture of Russian instruments is also an important goal of the program. The process was started with two portal monitor workshops attended by representatives of Russian facilities at ORNL and followed by technical collaborations at the individual Russian facilities. The success of this effort is illustrated by the recent workshop hosted by VNIIA at the SCI in Obninsk where specialists from thirty-two Russian nuclear facilities met to discuss their experience in portal monitoring. Twelve institutes and firms reported on the status of Russian designed and manufactured instruments. Details of this program will be presented in this paper

  2. Measuring thyroid uptake with hand-held radiation monitors

    International Nuclear Information System (INIS)

    Deschamps, M.

    1987-04-01

    With the use of Iodine 123, 125 and 131 and some compounds of Technetium-99 m, a fraction of the isotopes can be trapped in the thyroid of the technicians. We used the hand-held radiation contamination or survey meters of the nine (9) Nuclear medicine departments we visited to see if they were adequate for the evaluation of thyroid uptake of the users. Measurements on a neck-phanton helped us to determine a minimum detectable activity for each isotope. We were then able to check if the measurements of investigations and action levels were possible. None of the hand-held radiation monitors are completely satisfactory for the measure of thyroid uptake of the user. We discuss a class of equipment capable of measuring radiation emissions at the investigation level. Measurement at the action level is possible with meters having scintillation or proportional probes but none of them permits the discrimination in energy required for a quantitative evaluation of the radioisotopes used

  3. Gamma-ray detectors for intelligent, hand-held radiation monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1983-01-01

    Small radiation detectors based on HgI 2 , bismuth germanate (BGO), plastic, or NaI(Tl) detector materials were evaluated for use in small, lighweight radiation monitors. The two denser materials, HgI 2 and BGO, had poor resolution at low-energy and thus performed less well than NaI(Tl) in detecting low-energy gamma rays from bare, enriched uranium. The plastic scintillator, a Compton recoil detector, also performed less well at low gamma-ray energy. Two small NaI(Tl) detectors were suitable for detecting bare uranium and sheilded plutonium. One became part of a new lightweight hand-held monitor and the other found uses as a pole-mounted detector for monitoring hard-to-reach locations

  4. Detection of SNM by Pulsed Neutron Interrogation

    International Nuclear Information System (INIS)

    Pedersen, Bent; Mayorov, Valeriy; Roesgen, Eric; Mosconi, Marita; Crochemore, Jean-Michel; Ocherashvili, Aharon; Beck, Arie; Ettedgui, Hanania

    2014-01-01

    A method for the detection of special nuclear materials (SNM) in shielded containers which is both sensitive and easily applicable under field conditions is presented. The method applies neutron induced fission in SNM by means of an external pulsed neutron source with subsequent detection of the fast prompt fission neutrons. Liquid scintillation detectors surrounding the container under investigation are able to discriminate gamma rays from fast neutrons by the so-called pulse shape discrimination technique (PSD)

  5. Security improvements for rail movements of SNM

    International Nuclear Information System (INIS)

    Garcia, M.R.; Gronager, J.E.; Shemigon, N.N.

    1998-01-01

    The US Department of Energy (DOE) and the Russian Special Scientific and Production State Enterprise Eleron have teamed to lead a project to enhance the overall security of Russian Ministry of Atomic Energy (MINATOM) transportation of Special Nuclear Material (SNM) shipments. The effort is called the Railcar Transportation Security Project and is part of the overall DOE Material Protection, Control, and Accounting (MPC and A) program addressing the enhancement of nuclear material control, accounting, and physical protection for Russian SNM. The goal of this MPC and A project is to significantly increase the security of Russian MINATOM highly enriched SNM rail shipments. To accomplish this, the MPC and A Railcar Transportation Security program will provide an enhanced, yet cost effective, railcar transportation security system. The system incorporates a balance between the traditional detection, communications, delay, and response security elements to significantly improve the security of MINATOM SNM shipments. The strategy of this program is to use rapid upgrades to implement mature security technologies as quickly as possible. The rapid upgrades emphasize rapidly deployable delay elements, enhanced radio communications, and intrusion detection and surveillance. Upgraded railcars have begun operation during FY98. Subsequent upgrades will build upon the rapid upgrades and eventually be integrated into a final deployed system configuration. This paper provides an overview of the program, with a summary of performance of the deployed railcars

  6. Portal monitoring technology control process

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    Portal monitors are an important part of the material protection, control, and accounting (MPC and A) programs in Russia and the US. Although portal monitors are only a part of an integrated MPC and A system, they are an effective means of controlling the unauthorized movement of special nuclear material (SNM). Russian technical experts have gained experience in the use of SNM portal monitors from US experts ad this has allowed them to use the monitors more effectively. Several Russian institutes and companies are designing and manufacturing SNM portal monitors in Russia. Interactions between Russian and US experts have resulted in improvements to the instruments. SNM portal monitor technology has been effectively transferred from the US to Russia and should be a permanent part of the Russian MPC and A Program. Progress in the implementation of the monitors and improvements to how they are used are discussed

  7. Neutron spectrometer for improved SNM search.

    Energy Technology Data Exchange (ETDEWEB)

    Vance, Andrew L.; Aigeldinger, Georg

    2007-03-01

    With the exception of large laboratory devices with very low sensitivities, a neutron spectrometer have not been built for fission neutrons such as those emitted by special nuclear materials (SNM). The goal of this work was to use a technique known as Capture Gated Neutron Spectrometry to develop a solid-state device with this functionality. This required modifications to trans-stilbene, a known solid-state scintillator. To provide a neutron capture signal we added lithium to this material. This unique triggering signal allowed identification of neutrons that lose all of their energy in the detector, eliminating uncertainties that arise due to partial energy depositions. We successfully implemented a capture gated neutron spectrometer and were able to distinguish an SNM like fission spectrum from a spectrum stemming from a benign neutron source.

  8. Radioisotope Identification Of Shielded And Masked SNM RDD Materials

    International Nuclear Information System (INIS)

    Salaymeh, S.; Jeffcoat, R.

    2010-01-01

    Sonar and speech techniques have been investigated to improve functionality and enable handheld and other man-portable, mobile, and portal systems to positively detect and identify illicit nuclear materials, with minimal data and with minimal false positives and false negatives. RadSonar isotope detection and identification is an algorithm development project funded by NA-22 and employing the resources of Savannah River National Laboratory and three University Laboratories (JHU-APL, UT-ARL, and UW-APL). Algorithms have been developed that improve the probability of detection and decrease the number of false positives and negatives. Two algorithms have been developed and tested. The first algorithm uses support vector machine (SVM) classifiers to determine the most prevalent nuclide(s) in a spectrum. It then uses a constrained weighted least squares fit to estimate and remove the contribution of these nuclide(s) to the spectrum, iterating classification and fitting until there is nothing of significance left. If any Special Nuclear Materials (SNMs) were detected in this process, a second tier of more stringent classifiers are used to make the final SNM alert decision. The second algorithm is looking at identifying existing feature sets that would be relevant in the radioisotope identification context. The underlying philosophy here is to identify parallels between the physics and/or the structures present in the data for the two applications (speech analysis and gamma spectroscopy). The expectation is that similar approaches may work in both cases. The mel-frequency cepstral representation of spectra is widely used in speech, particularly for two reasons: approximation of the response of the human ear, and simplicity of channel effect separation (in this context, a 'channel' is a method of signal transport that affects the signal, examples being vocal tract shape, room echoes, and microphone response). Measured and simulated gamma-ray spectra from a hand-held

  9. Detector placement optimization for cargo containers using deterministic adjoint transport examination for SNM detection

    International Nuclear Information System (INIS)

    McLaughlin, Trevor D.; Sjoden, Glenn E.; Manalo, Kevin L.

    2011-01-01

    With growing concerns over port security and the potential for illicit trafficking of SNM through portable cargo shipping containers, efforts are ongoing to reduce the threat via container monitoring. This paper focuses on answering an important question of how many detectors are necessary for adequate coverage of a cargo container considering the detection of neutrons and gamma rays. Deterministic adjoint transport calculations are performed with compressed helium- 3 polyethylene moderated neutron detectors and sodium activated cesium-iodide gamma-ray scintillation detectors on partial and full container models. Results indicate that the detector capability is dependent on source strength and potential shielding. Using a surrogate weapons grade plutonium leakage source, it was determined that for a 20 foot ISO container, five neutron detectors and three gamma detectors are necessary for adequate coverage. While a large CsI(Na) gamma detector has the potential to monitor the entire height of the container for SNM, the He-3 neutron detector is limited to roughly 1.25 m in depth. Detector blind spots are unavoidable inside the container volume unless additional measures are taken for adequate coverage. (author)

  10. The expression of the rice (Oryza sativa L.) homologue of Snm1 is induced by DNA damages

    International Nuclear Information System (INIS)

    Kimura, Seisuke; Saotome, Ai; Uchiyama, Yukinobu; Mori, Yoko; Tahira, Yasue; Sakaguchi, Kengo

    2005-01-01

    We isolated and characterized the rice homologue of the DNA repair gene Snm1 (OsSnm1). The length of the cDNA was 1862 bp; the open reading frame encoded a predicted product of 485 amino acid residues with a molecular mass of 53.2 kDa. The OsSnm1 protein contained the conserved β-lactamase domain in its internal region. OsSnm1 was expressed in all rice organs. The expression was induced by MMS, H 2 O 2 , and mitomycin C, but not by UV. Transient expression of an OsSnm1/GFP fusion protein in onion epidermal cells revealed the localization of OsSnm1 to the nucleus. These results suggest that OsSnm1 is involved not only in the repair of DNA interstrand crosslinks, but also in various other DNA repair pathways

  11. Silicon nanopore membrane (SNM) for islet encapsulation and immunoisolation under convective transport

    Science.gov (United States)

    Song, Shang; Faleo, Gaetano; Yeung, Raymond; Kant, Rishi; Posselt, Andrew M.; Desai, Tejal A.; Tang, Qizhi; Roy, Shuvo

    2016-03-01

    Problems associated with islet transplantation for Type 1 Diabetes (T1D) such as shortage of donor cells, use of immunosuppressive drugs remain as major challenges. Immune isolation using encapsulation may circumvent the use of immunosuppressants and prolong the longevity of transplanted islets. The encapsulating membrane must block the passage of host’s immune components while providing sufficient exchange of glucose, insulin and other small molecules. We report the development and characterization of a new generation of semipermeable ultrafiltration membrane, the silicon nanopore membrane (SNM), designed with approximately 7 nm-wide slit-pores to provide middle molecule selectivity by limiting passage of pro-inflammatory cytokines. Moreover, the use of convective transport with a pressure differential across the SNM overcomes the mass transfer limitations associated with diffusion through nanometer-scale pores. The SNM exhibited a hydraulic permeability of 130 ml/hr/m2/mmHg, which is more than 3 fold greater than existing polymer membranes. Analysis of sieving coefficients revealed 80% reduction in cytokines passage through SNM under convective transport. SNM protected encapsulated islets from infiltrating cytokines and retained islet viability over 6 hours and remained responsive to changes in glucose levels unlike non-encapsulated controls. Together, these data demonstrate the novel membrane exhibiting unprecedented hydraulic permeability and immune-protection for islet transplantation therapy.

  12. Environmental-impact appraisal related to special nuclear materials. License No. SNM-696; Docket No. 70-734

    International Nuclear Information System (INIS)

    1983-06-01

    This Environmental Impact Appraisal is issued by the US Nuclear Regulatory Commission in response to an application by GA Technologies, Inc., (GA) for renewal of Special Nuclear Material (SNM) License No. SNM-696 covering plant operations at San Diego, California. The proposed action provides for continuing research, development, and production activities involving SNM, uranium enriched in the U-235 and U-233 isotopes, and plutonium

  13. Use of Sources and SNM in COE Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Archuleta, Jeffrey Christopher [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-07

    This procedure describes how to use Special Nuclear Material (SNM) and sources in order to perform measurements in a safe manner. The hazards and controls associated with these activities are addressed in this document.

  14. Lessons learned in streamlining the preparation of SNM standard solutions

    International Nuclear Information System (INIS)

    Clark, J.P.; Johnson, S.R.

    1986-01-01

    Improved safeguard measurements have produced a demand for greater quantities of reliable SNM solution standards. At the Savannah River Plant (SRP), the demand for these standards has been met by several innovations to improve the productivity and reliability of standards preparations. With the use of computer controlled balance, large batches of SNM stock solutions are prepared on a gravimetric basis. Accurately dispensed quantities of the stock solution are weighed and stored in bottles. When needed, they are quantitatively transferred to tared containers, matrix adjusted to target concentrations, weighed, and measured for density at 25 0 C. Concentrations of SNM are calculated both gravimetrically and volumetrically. Calculated values are confirmed analytically before the standards are used in measurement control program (MCP) activities. The lessons learned include: MCP goals include error identification and management. Strategy modifications are required to improve error management. Administrative controls can minimize certain types of errors. Automation can eliminate redundancy and streamline preparations. Prudence and simplicity enhance automation success. The effort expended to increase productivity has increased the reliability of standards and provided better documentation for quality assurance

  15. Standard guide for application of radiation monitors to the control and physical security of special nuclear material

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1999-01-01

    1.1 This guide briefly describes the state-of-the-art of radiation monitors for detecting special nuclear material (SNM) (see 3.1.11) in order to establish the context in which to write performance standards for the monitors. This guide extracts information from technical documentation to provide information for selecting, calibrating, testing, and operating such radiation monitors when they are used for the control and protection of SNM. This guide offers an unobtrusive means of searching pedestrians, packages, and motor vehicles for concealed SNM as one part of a nuclear material control or security plan for nuclear materials. The radiation monitors can provide an efficient, sensitive, and reliable means of detecting the theft of small quantities of SNM while maintaining a low likelihood of nuisance alarms. 1.2 Dependable operation of SNM radiation monitors rests on selecting appropriate monitors for the task, operating them in a hospitable environment, and conducting an effective program to test, calibrat...

  16. Project Plan For Remove Special Nuclear Material (SNM) from Plutonium Finishing Plant (PFP) Project

    International Nuclear Information System (INIS)

    BARTLETT, W.D.

    1999-01-01

    This plan presents the overall objectives, description, justification and planning for the Plutonium Finishing Plant (PFP) Remove SNM Materials. The intent of this plan is to describe how this project will be managed and integrated with other facility stabilization and deactivation activities. This plan supplements the overall integrated plan presented in the Plutonium Finishing Plant Integrated Project Management Plan (IPMP), HNF-3617. This project plan is the top-level definitive project management document for the PFP Remove SNM Materials project. It specifies the technical, schedule, requirements and the cost baseline to manage the execution of the Remove SNM Materials project. Any deviation to the document must be authorized through the appropriate change control process. The Remove SNM Materials project provides the necessary support and controls required for DOE-HQ, DOE-RL, BWHC, and other DOE Complex Contractors the path forward to negotiate shipped/receiver agreements, schedule shipments, and transfer material out of PFP to enable final deactivation

  17. Strategic Niche Management (SNM) beyond sustainability : an exploration of key findings of SNM through the lens of ICT and privacy

    NARCIS (Netherlands)

    Schilpzand, W.F.; Raven, R.P.J.M.; Est, van Q.C.

    2011-01-01

    The governance of transitions to sustainability is gaining attention. This paper discusses the approach of strategic niche management (SNM) and contributes by asking whether this approach is also useful for other types of socially desirable change. This question is addressed through a review of six

  18. 77 FR 22362 - Exemption Requests for Special Nuclear Material License SNM-362, Department of Commerce...

    Science.gov (United States)

    2012-04-13

    ... Nuclear Material License SNM-362, Department of Commerce, Gaithersburg, MD AGENCY: Nuclear Regulatory... Commerce, National Institutes of Standards and Technology (NIST) in Gaithersburg, Maryland. NIST requested... within the Department of Commerce. The SNM license was renewed in 1979, 1985, 1991, and 1997. The current...

  19. Handheld Multi-Gas Meters Market Survey Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-23

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the chemical monitored. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. To provide emergency responders with information on handheld multi-gas meters, the System Assessment and Validation for Emergency Responders (SAVER) Program conducted a market survey. This market survey report is based on information gathered between November 2015 and February 2016 from vendors, Internet research, industry publications, an emergency responder focus group, and a government issued Request for Information (RFI) that was posted on the Federal Business Opportunities website.

  20. Exporting automatic vehicle SNM monitoring technology

    International Nuclear Information System (INIS)

    York, R.L.; Fehlau, P.E.; Close, D.A.

    1995-01-01

    Controlling the transportation of nuclear materials is still one of the most effective nuclear proliferation barriers. The recent increase of global nuclear material proliferation has expanded the application of vehicle monitor technology to prevent the diversion of special nuclear material across international borders. To satisfy this new application, a high-sensitivity vehicle monitor, which is easy to install and capable of operating in high-traffic areas, is required. A study of a new detector configuration for a drive-through vehicle monitor is discussed in this paper

  1. Standard guide for application of radiation monitors to the control and physical security of special nuclear material

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    This guide briefly describes the state-of-the-art of radiation monitors for detecting special nuclear material (SNM) in order to establish the context in which to write performance standards for the monitors. This guide extracts information from technical documentation to provide information for selecting, calibrating, testing, and operating such radiation monitors when they are used for the control and protection of SNM. This guide offers an unobtrusive means of searching pedestrians, packages, and motor vehicles for concealed SNM as one part of a nuclear material control or security plan for nuclear materials. The radiation monitors can provide an efficient, sensitive, and reliable means of detecting the theft of small quantities of SNM while maintaining a low likelihood of nuisance alarms

  2. Human SNM1B is required for normal cellular response to both DNA interstrand crosslink-inducing agents and ionizing radiation.

    Science.gov (United States)

    Demuth, Ilja; Digweed, Martin; Concannon, Patrick

    2004-11-11

    DNA interstrand crosslinks (ICLs) are critical lesions for the mammalian cell since they affect both DNA strands and block transcription and replication. The repair of ICLs in the mammalian cell involves components of different repair pathways such as nucleotide-excision repair and the double-strand break/homologous recombination repair pathways. However, the mechanistic details of mammalian ICL repair have not been fully delineated. We describe here the complete coding sequence and the genomic organization of hSNM1B, one of at least three human homologs of the Saccharomyces cerevisiae PSO2 gene. Depletion of hSNM1B by RNA interference rendered cells hypersensitive to ICL-inducing agents. This requirement for hSNM1B in the cellular response to ICL has been hypothesized before but never experimentally verified. In addition, siRNA knockdown of hSNM1B rendered cells sensitive to ionizing radiation, suggesting the possibility of hSNM1B involvement in homologous recombination repair of double-strand breaks arising as intermediates of ICL repair. Monoubiquitination of FANCD2, a key step in the FANC/BRCA pathway, is not affected in hSNM1B-depleted HeLa cells, indicating that hSNM1B is probably not a part of the Fanconi anemia core complex. Nonetheless, similarities in the phenotype of hSNM1B-depleted cells and cultured cells from patients suffering from Fanconi anemia make hSNM1B a candidate for one of the as yet unidentified Fanconi anemia genes not involved in monoubiquitination of FANCD2.

  3. Process monitoring

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Many of the measurements and observations made in a nuclear processing facility to monitor processes and product quality can also be used to monitor the location and movements of nuclear materials. In this session information is presented on how to use process monitoring data to enhance nuclear material control and accounting (MC and A). It will be seen that SNM losses can generally be detected with greater sensitivity and timeliness and point of loss localized more closely than by conventional MC and A systems if process monitoring data are applied. The purpose of this session is to enable the participants to: (1) identify process unit operations that could improve control units for monitoring SNM losses; (2) choose key measurement points and formulate a loss indicator for each control unit; and (3) describe how the sensitivities and timeliness of loss detection could be determined for each loss indicator

  4. Upgrades for truck transportation of SNM in the Russian Federation

    International Nuclear Information System (INIS)

    Gardner, B.H.; Kornilovich, E.

    1998-01-01

    The goal of this project is the rapid reduction of risk to truck transportation of SNM in Russia. Enhanced protection is being accomplished by cooperation between the US Department of Energy, MINATOM of Russia, the Russian Ministry of Defense, and various Russian Institutes. This program provides an integrated program of specialized trucks that are equipped with hardened overpack (SNM vault) containers, alarm and communications systems, and armored cabs. Armored escort vehicles are also provided to increase the survivability of the guards escorting convoys. Only indigenous Russian equipment, modified and/or manufactured by Designing Bureau for Motor Vehicle Transport Equipment (KBATO), is provided under this program. The US will not provide assistance in the truck transportation arena without a commitment from the Russian facility to provide heavily armed escorts for SNM movement. Each site conducts a detailed transportation needs assessment study that is used as the basis for prioritizing assistance. The Siberian Chemical Combine (Tomsk-7) was the initial site of cooperation. The designs used at Tomsk-7 are serving as the baseline for all future vehicles modified under this program. In FY98, many vehicles systems have been ordered for various institutes. Many additional systems will be ordered in FY99

  5. 75 FR 2163 - Constellation Energy; Notice of Docketing of Special Nuclear Material License SNM-2505 Amendment...

    Science.gov (United States)

    2010-01-14

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 72-8; NRC-2010-0011] Constellation Energy; Notice of Docketing of Special Nuclear Material License SNM-2505 Amendment Application for the Calvert Cliffs... Constellation Energy (Constellation) to amend its Special Nuclear Material License No. SNM-2505, under the...

  6. Monitoring invasive plants using hand-held GIS technology

    Science.gov (United States)

    Theresa M. Mau-Crimmins; Barron J. Orr

    2005-01-01

    Successful control of invasive species requires a clear picture of the spatial extent of infestations. The latest mapping technology involves coupling global position systems and handheld computers running geographic information systems software in the field. A series of workshops applying this technology to mapping weeds was developed and presented to Weed Management...

  7. Considerations for sampling nuclear materials for SNM accounting measurements

    International Nuclear Information System (INIS)

    Brouns, R.J.; Roberts, F.P.; Upson, U.L.

    1978-01-01

    This report presents principles and guidelines for sampling nuclear materials to measure chemical and isotopic content of the material. Development of sampling plans and procedures that maintain the random and systematic errors of sampling within acceptable limits for SNM accounting purposes are emphasized

  8. 76 FR 55711 - Confirmatory Order Modifying License No. SNM-2001 for the Shallow Land Disposal Area, Parks...

    Science.gov (United States)

    2011-09-08

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 40-8907; NRC-2011-0193] Confirmatory Order Modifying License No. SNM-2001 for the Shallow Land Disposal Area, Parks Township, Armstrong County, PA; Notice of... (SNM), pursuant to the terms and conditions of the aforementioned License, at the Shallow Land Disposal...

  9. Development of Real-Time Dual-Display Handheld and Bench-Top Hybrid-Mode SD-OCTs

    Directory of Open Access Journals (Sweden)

    Nam Hyun Cho

    2014-01-01

    Full Text Available Development of a dual-display handheld optical coherence tomography (OCT system for retina and optic-nerve-head diagnosis beyond the volunteer motion constraints is reported. The developed system is portable and easily movable, containing the compact portable OCT system that includes the handheld probe and computer. Eye posterior chambers were diagnosed using the handheld probe, and the probe could be fixed to the bench-top cradle depending on the volunteers’ physical condition. The images obtained using this handheld probe were displayed in real time on the computer monitor and on a small secondary built-in monitor; the displayed images were saved using the handheld probe’s built-in button. Large-scale signal-processing procedures such as k-domain linearization, fast Fourier transform (FFT, and log-scaling signal processing can be rapidly applied using graphics-processing-unit (GPU accelerated processing rather than central-processing-unit (CPU processing. The Labview-based system resolution is 1,024 × 512 pixels, and the frame rate is 56 frames/s, useful for real-time display. The 3D images of the posterior chambers including the retina, optic-nerve head, blood vessels, and optic nerve were composed using real-time displayed images with 500 × 500 × 500 pixel resolution. A handheld and bench-top hybrid mode with a dual-display handheld OCT was developed to overcome the drawbacks of the conventional method.

  10. Fusing Open Source Intelligence and Handheld Situational Awareness - Benghazi Case Study

    Science.gov (United States)

    2014-10-01

    1 DM-0001694 Fusing Open Source Intelligence and Handheld Situational Awareness Benghazi Case Study Jeff Boleng, PhD Marc Novakouski Gene...command and control element at the CIA compound that would have been monitoring OSINT and other sources of intelligence before the attack and... Source Intelligence and Handheld Situational Awareness - Benghazi Case Study 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6

  11. Real time loss detection for SNM in process

    International Nuclear Information System (INIS)

    Candy, J.V.; Dunn, D.R.; Gavel, D.T.

    1980-01-01

    This paper discusses the basis of a design for real time special nuclear material (SNM) loss detectors. The design utilizes process measurements and signal processing techniques to produce a timely estimate of material loss. A state estimator is employed as the primary signal processing algorithm. Material loss is indicated by changes in the states or process innovations (residuals). The design philosophy is discussed in the context of these changes

  12. DNA aptamer beacon assay for C-telopeptide and handheld fluorometer to monitor bone resorption.

    Science.gov (United States)

    Bruno, John Gordon; Carrillo, Maria P; Phillips, Taylor; Hanson, Douglas; Bohmann, Jonathan A

    2011-09-01

    A novel DNA aptamer beacon is described for quantification of a 26-amino acid C-telopeptide (CTx) of human type I bone collagen. One aptamer sequence and its reverse complement dominated the aptamer pool (31.6% of sequenced clones). Secondary structures of these aptamers were examined for potential binding pockets. Three-dimensional computer models which analyzed docking topologies and binding energies were in agreement with empirical fluorescence experiments used to select one candidate loop for beacon assay development. All loop structures from the aptamer finalists were end-labeled with TYE 665 and Iowa Black quencher for comparison of beacon fluorescence levels as a function of CTx concentration. The optimal beacon, designated CTx 2R-2h yielded a low ng/ml limit of detection using a commercially available handheld fluorometer. The CTx aptamer beacon bound full-length 26-amino acid CTx peptide, but not a shorter 8-amino acid segment of CTx peptide which is a common target for commercial CTx ELISA kits. The prototype assay was shown to detect CTx peptide from human urine after creatinine and urea were removed by size-exclusion chromatography to prevent nonspecific denaturing of the aptamer beacon. This work demonstrates the potential of aptamer beacons to be utilized for rapid and sensitive bone health monitoring in a handheld or point-of-care format.

  13. Technical evaluation of Tom Scurry Associates: Model PM-203 doorway monitor

    International Nuclear Information System (INIS)

    1978-07-01

    Under a basic assignment by the Office of Safeguards and Security, the Tom Scurry Associates Model PM-203 Personnel Doorway SNM Monitor manufactured by Tom Scurry Associates was evaluated by LASL Group Q-2 against the DOE Personnel Doorway Monitor standards. During the evaluation, a small change was required in detector shielding to eliminate low sensitivity areas at the portal sides. With the modified shielding described, the PM-203 meets the Office of Safeguards and Security SNM doorway monitor specifications for detecting either 235 U or 239 Pu-- 233 U. This system is also capable of monitoring 238 Pu

  14. Data for Users of Handheld Ion Mobility Spectrometers

    International Nuclear Information System (INIS)

    Keith A. Daum; Sandra L. Fox

    2008-01-01

    Chemical detection technology end-user surveys conducted by Idaho National Laboratory (INL) in 2005 and 2007 indicated that first responders believed manufacturers claims for instruments sometimes were not supported in field applications, and instruments sometimes did not meet their actual needs. Based on these findings, the Department of Homeland Security (DHS) asked INL to conduct a similar survey for handheld ion mobility spectrometers (IMS), which are used by a broad community of first responders as well as for other applications. To better access this broad community, the INL used the Center for Technology Commercialization, Inc. (CTC), Public Safety Technology Center (PSTC) to set up an online framework to gather information from users of handheld IMS units. This framework (Survey Monkey) was then used to perform an online Internet survey, augmented by e-mail prompts, to get information from first responders and personnel from various agencies about their direct experience with handheld IMS units. Overall, 478 individuals responded to the survey. Of these, 174 respondents actually owned a handheld IMS. Performance and satisfaction data from these 174 respondents are captured in this report. The survey identified the following observations: (1) The most common IMS unit used by respondents was the Advanced Portable Detector (APD 2000), followed by ChemRae, Sabre 4000, Sabre 2000, Draeger Multi IMS, Chemical Agent Monitor-2, Chemical Agent Monitor, Vapor Tracer, and Vapor Tracer 2. (2) The primary owners were HazMat teams (20%), fire services (14%), local police (12%), and sheriffs departments (9%). (3) IMS units are seldom used as part of an integrated system for detecting and identifying chemicals but instead are used independently. (4) Respondents are generally confused about the capabilities of their IMS unit. This is probably a result of lack of training. (5) Respondents who had no training or fewer than 8 hours were not satisfied with the overall operation

  15. Handheld juggernaut.

    Science.gov (United States)

    Hagland, Mark

    2010-08-01

    Not only are hospital, health system, and medical group ClOs and clinical informaticists deploying handheld mobile devices across their enterprises as clinical computing tools; clinicians, especially physicians, are increasingly bringing their own BlackBerrys, iPhones, iPads, Android devices, and other handhelds, into patient care organizations for their personal clinical use. Not surprisingly, the challenges--as well as the opportunities--are multilayered and complex, and include the strategic planning, infrastructure, clinician preference, clinician workflow, and security issues involved in the emerging mobile handheld revolution. The diversity of approaches among ClOs and other healthcare IT leaders on such issues is striking, and underscores the need for flexibility and nimbleness going forward.

  16. Kalman-filter model for determining block and trickle SNM losses

    International Nuclear Information System (INIS)

    Barlow, R.E.; Durst, M.J.; Smiriga, N.G.

    1982-07-01

    This paper describes an integrated decision procedure for deciding whether a diversion of SNM has occurred. Two possible types of diversion are considered: a block loss during a single time period and a cumulative trickle loss over several time periods. The methodology used is based on a compound Kalman filter model. Numerical examples illustrate our approach

  17. Tempering of accounts and records to disguise SNM theft

    International Nuclear Information System (INIS)

    Lim, J.J.; Huebel, J.G.

    1979-07-01

    A typical nuclear material accounting system employing double-entry bookkeeping is described. A logic diagram is used to model the interactions of the accounting system and the adversary when he attempts to thwart it. Boolean equations are derived from the logic diagram; solution of these equations yields the accounts and records through which the adversary may disguise SNM theft and the collusion requirements needed to accomplish this feat

  18. Diagnostic efficacy of handheld devices for emergency radiologic consultation.

    LENUS (Irish Health Repository)

    Toomey, Rachel J

    2010-02-01

    Orthopedic injury and intracranial hemorrhage are commonly encountered in emergency radiology, and accurate and timely diagnosis is important. The purpose of this study was to determine whether the diagnostic accuracy of handheld computing devices is comparable to that of monitors that might be used in emergency teleconsultation.

  19. Elcodrum I, a tamper-resistant and integrity controlled container for SNM

    International Nuclear Information System (INIS)

    Bueker, H.; Arning, F.; Reuters, H.; Nicolai, S.

    1984-01-01

    The safekeeping of special nuclear material (SNM) requires the use of a container with opening and surface area protection, which means that any access to the nuclear material whether by opening or damaging the container shell must be recorded. Based on the optoelectronic sensor principle, a 55-gallon drum with opening and surface area protection has been developed for which the opening status as well as the integrity of its entire surface can be verified at any time in a tamperproof manner. This may be done either ''in situ'' or from a remote monitoring station by means of a computer-aided remote verification system. The prototype of such a container has been successfully tested for more than five months at the Juelich Nuclear Research Center. It can be used both for national and international nuclear materials safeguards. It also offers itself for application in the planned ''International Plutonium Storage (IPS)'' system. The design and functioning of the container as well as the use of several containers in conjunction with a computer-aided remote verification system will be described

  20. An expert system to estimate SNM production at LWR systems

    International Nuclear Information System (INIS)

    Sandquist, G.M.; Allison, J.L.; Rogers, V.C.

    1988-01-01

    An artificial intelligence expert system, analysis of proliferation by expert system (APES), has been developed and tested to permit a nonexpert to quickly evaluate the capabilities and capacities of a reactor and reprocessing system for producing and separating plutonium [special nuclear material (SNM)] even when system information may be limited and uncertain. The present analysis domain of APES is directed at light water reactors and Purex reprocessing, but extension of the domain is planned

  1. Integrated neutron/gamma-ray portal monitors for nuclear safeguards

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1994-01-01

    Radiation monitoring is one nuclear-safeguards measure used to protect against the theft of special nuclear materials (SNM) by pedestrians departing from SNM access areas. The integrated neutron/gamma-ray portal monitor is an ideal radiation monitor for the task when the SNM is plutonium. It achieves high sensitivity for detecting both bare and shielded plutonium by combining two types of radiation detector. One type is a neutron-chamber detector, comprising a large, hollow, neutron moderator that contains a single thermal-neutron proportional counter. The entrance wall of each chamber is thin to admit slow neutrons from plutonium contained in a moderating shield, while the other walls are thick to moderate fast neutrons from bare or lead-shielded plutonium so that they can be detected. The other type of detector is a plastic scintillator that is primarily for detecting gamma rays from small amounts of unshielded plutonium. The two types of detector are easily integrated by making scintillators part of the thick back wall of each neutron chamber or by inserting them into each chamber void. The authors compared the influence of the two methods of integration on detecting neutrons and gamma rays, and they examined the effectiveness of other design factors and the methods for signal detection as well

  2. Department of Energy (DOE) system for the transportation of strategic quantities of special nuclear material (SQ SNM)

    International Nuclear Information System (INIS)

    Dickason, D.P.

    1978-01-01

    Since 1947 DOE and its predecessor agencies, AEC and ERDA, have moved nuclear materials by a variety of commercial and government transportation modes. In the late 1960's world-wide terrorism and other dissident activities prompted the then-AEC to review its procedures for safeguarding SNM. These reviews resulted in immediate and long-range programs for improvement of overall safeguards. Domestic transportation of completed nuclear weapons and SNM used in the weapons program was selected for special consideration. In the early 1970's AEC started the development of a Safe Secure Trailer (SST) to transport nuclear weapons and nuclear components and the development and installation of a high frequency (HF) communications system to assure continuous radio contact between selected highway and rail shipments and Headquarters, Albuquerque Operations (ALO). Late 1974 AEC directed ALO to develop a transportation system to extend weapons-level protection to all AEC SQ SNM shipments and to consolidate, manage, and operate this system. As of September 1976 all SQ SNM was being transported in the Safe Secure DOE (then ERDA) transportation safeguards system, composed of the following principal elements: (1) Transport equipment consisting of Safe Secure Trailers and specially modified towing tractors; Safe Secure Railcars and specially modified escort coaches; and specially designed highway escort vehicles. (2) An automated high-frequency digital radio system that enables continuous communications between the transporting equipment and central control. (3) A courier force that operates all transport equipment (except aircraft and rail power units) and mobile communications equipment; provides armed protection for shipments; and assures proper safety en route. (4) A central Headquarters staff that plans, executes, and controls shipments and directs, manages, and operates the system

  3. Handheld Multi-Gas Meters Assessment Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Gustavious [Brigham Young Univ., Provo, UT (United States); Wald-Hopkins, Mark David [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Obrey, Stephen J. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Akhadov, Valida Dushdurova [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-27

    Handheld multi-gas meters (MGMs) are equipped with sensors to monitor oxygen (O2) levels and additional sensors to detect the presence of combustible or toxic gases in the environment. This report is limited to operational response-type MGMs that include at least four different sensors. These sensors can vary by type and by the monitored chemical. In real time, the sensors report the concentration of monitored gases in the atmosphere near the MGM. In April 2016 the System Assessment and Validation for Emergency Responders (SAVER) Program conducted an operationally-oriented assessment of MGMs. Five MGMs were assessed by emergency responders. The criteria and scenarios used in this assessment were derived from the results of a focus group of emergency responders with experience in using MGMs. The assessment addressed 16 evaluation criteria in four SAVER categories: Usability, Capability, Maintainability, and Deployability.

  4. Application of Handheld Tele-ECG for Health Care Delivery in Rural India

    Directory of Open Access Journals (Sweden)

    Meenu Singh

    2014-01-01

    Full Text Available Telemonitoring is a medical practice that involves remotely monitoring patients who are not at the same location as the health care provider. The purpose of our study was to use handheld tele-electrocardiogram (ECG developed by Bhabha Atomic Research Center (BARC to identify heart conditions in the rural underserved population where the doctor-patient ratio is low and access to health care is difficult. The objective of our study was clinical validation of handheld tele-ECG as a screening tool for evaluation of cardiac diseases in the rural population. ECG was obtained in 450 individuals (mean age 31.49 ± 20.058 residing in the periphery of Chandigarh, India, from April 2011 to March 2013, using the handheld tele-ECG machine. The data were then transmitted to physicians in Postgraduate Institute of Medical Education and Research (PGIMER, Chandigarh, for their expert opinion. ECG was interpreted as normal in 70% individuals. Left ventricular hypertrophy (9.3% was the commonest abnormality followed closely by old myocardial infarction (5.3%. Patient satisfaction was reported to be ~95%. Thus, it can be safely concluded that tele-ECG is a portable, cost-effective, and convenient tool for diagnosis and monitoring of heart diseases and thus improves quality and accessibility, especially in rural areas.

  5. Characterizing the reflectivity of handheld display devices.

    Science.gov (United States)

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements

  6. Considerations for sampling nuclear materials for SNM accounting measurements. Special nuclear material accountability report

    International Nuclear Information System (INIS)

    Brouns, R.J.; Roberts, F.P.; Upson, U.L.

    1978-05-01

    This report presents principles and guidelines for sampling nuclear materials to measure chemical and isotopic content of the material. Development of sampling plans and procedures that maintain the random and systematic errors of sampling within acceptable limits for SNM(Special Nuclear Materials) accounting purposes are emphasized

  7. ICPP digital wide area portal monitor

    International Nuclear Information System (INIS)

    Nichols, C.E.

    1978-01-01

    A portal montior is described which is used to check personnel for contamination. The monitor is extremely sensitive. In addition to personnel contamination control, it serves as an extremely effective SNM detector capable of detecting U-235 in half the quantities specified in Federal Standards

  8. Hand-held medical robots.

    Science.gov (United States)

    Payne, Christopher J; Yang, Guang-Zhong

    2014-08-01

    Medical robots have evolved from autonomous systems to tele-operated platforms and mechanically-grounded, cooperatively-controlled robots. Whilst these approaches have seen both commercial and clinical success, uptake of these robots remains moderate because of their high cost, large physical footprint and long setup times. More recently, researchers have moved toward developing hand-held robots that are completely ungrounded and manipulated by surgeons in free space, in a similar manner to how conventional instruments are handled. These devices provide specific functions that assist the surgeon in accomplishing tasks that are otherwise challenging with manual manipulation. Hand-held robots have the advantages of being compact and easily integrated into the normal surgical workflow since there is typically little or no setup time. Hand-held devices can also have a significantly reduced cost to healthcare providers as they do not necessitate the complex, multi degree-of-freedom linkages that grounded robots require. However, the development of such devices is faced with many technical challenges, including miniaturization, cost and sterility, control stability, inertial and gravity compensation and robust instrument tracking. This review presents the emerging technical trends in hand-held medical robots and future development opportunities for promoting their wider clinical uptake.

  9. Application of Suresight handheld auto-refractometer in refraction screening for infants in Community Health Service Center

    Directory of Open Access Journals (Sweden)

    Li-Hua Guo

    2014-08-01

    Full Text Available AIM: To observe the application of Suresight handheld auto-refractometer in measuring diopter of infants in Community Health Service Center. METHODS:Totally 836 cases(1 672 eyesfrom June 2013 to December 2013 were examined diopter of infants by Suresight handheld auto-refractometer in Community Health Service Center. RESULTS: Within 1 672 eyes of 836 infants were examined, 202 eyes were diagnosed ametropia, 38 eyes were suspicious, 240 eyes were transferred to the department of ophthalmology, the referral rate was 14.35%; 172 eyes were diagnosed ametropia, and the diagnosis rate of the referral patients was 71.67%. Among 172 eyes, 46 eyes were provided with corrected glasses, accounting for 2.75% of the number of screening, and 126 eyes were given intensive monitoring, accounting for 7.54% of the number of screening.CONCLUSION: Application of Suresight handheld auto-refractometer in refraction screening for infants in Community Health Service Center is convenient and effective. With two-way referral between community health service center and department of ophthalmology can monitor and intervene vision development of infants much earlier.

  10. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry

    NARCIS (Netherlands)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H.; Tol, Johannes L.; Verhaar, Jan A. N.; Weir, Adam

    2016-01-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of

  11. Criteria for a comparative assessment on handheld gamma-ray measurement tools

    International Nuclear Information System (INIS)

    Feichtinger, J.; Schwaiger, M.; Schmitzer, C.; Kindl, P.

    2001-01-01

    Full text: The radionuclide laboratories at the Austrian Research Centres Seibersdorf are strongly involved in radiation protection of public and employees as well as in environmental monitoring with special concern to gamma spectrometric measurements. Hence, field measurements and therefore the subject of hand-held measurement devices is a topic of main interest. Taking into consideration, that these hand-held measurement tool are further used in critical and sensitive operations, as for example by the IAEA Safeguards or by CTBTO On-Site inspectors, a standard for characterising these gamma measurement tools seems to be sound as necessary. The poster presents a set of technical criteria as well as limiting values, which allows an objective comparison of hand-held measurement devices. The criteria can be divided into three individual parts: radiometric characteristics, ergonomics and usability in field operations. The main criteria for testing the radiometry performance of hand-held measurement devices are sensitivity, efficiency, energy response, energy resolution and nuclide identification or not identification (if necessary), detection probability, dose rate indication, uncertainty, etc. The ergonomic test contains as dominating parts handling and quality of the manual. To evaluate the applicability in field operations different environmental conditions (e.g. light conditions, temperature range, moisture...) as well as battery lifetime and weight should be taken into account. These criteria may vary in dependence of the requirements or limitations given by various external conditions, but still a standard to evaluate and will give the opportunity to provide an objective comparison. (author)

  12. Status report on the TSA Systems, Ltd., MCA465 gamma-ray confirmation instrument

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Rutherford, D.A.

    1994-01-01

    The TSA Systems, Ltd., MCA465 is hand-portable, low resolution, gamma-ray instrument for confirming special nuclear materials (SNM) and related applications. The instrument evolved from earlier TSA Systems hand-held instruments, and, since its inception in 1991, it has been undergoing cycles of evaluation and then repair or redesign to correct problems. Through the efforts of Los Alamos, Rocky Flats, and TSA Systems, the MCA465 now has achieved commendable progress toward achieving quality performance as a rapid confirmation tool for SNM

  13. 30 CFR 56.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 56.12033 Section 56.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL....12033 Hand-held electric tools. Hand-held electric tools shall not be operated at high potential...

  14. 30 CFR 57.12033 - Hand-held electric tools.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand-held electric tools. 57.12033 Section 57.12033 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL... Surface and Underground § 57.12033 Hand-held electric tools. Hand-held electric tools shall not be...

  15. CSER 94-015: New portable NDA equipment for use in SNM audits

    Energy Technology Data Exchange (ETDEWEB)

    Hess, A.L.

    1994-12-12

    A criticality safety review is presented for the use of two portable NDA detectors from Los Alamos during an IAEA inspection of the SNM at PFP. The units are an Active Well Coincidence Counter (AWCC) and a High Level Neutron Coincidence Counter (HLNCC). Approval for their employment is based on the inherent safety of the containers to be assayed, one at a time, and because their designs conform with the acceptability criteria which allow the other NDA detectors currently employed at the facility.

  16. Municipalities in action. Comment to the article 'Slow with air quality plans' of the SNM

    International Nuclear Information System (INIS)

    2006-01-01

    The Association of Dutch Municipalities (VNG) does not agree with the environmental organization SNM, which states in another article in this issue of the magazine that municipalities in the Netherlands are slow in setting up and implementing air quality plans. From a VNG study it appears that investments are made to improve the air quality [nl

  17. Correcting for motion artifact in handheld laser speckle images

    Science.gov (United States)

    Lertsakdadet, Ben; Yang, Bruce Y.; Dunn, Cody E.; Ponticorvo, Adrien; Crouzet, Christian; Bernal, Nicole; Durkin, Anthony J.; Choi, Bernard

    2018-03-01

    Laser speckle imaging (LSI) is a wide-field optical technique that enables superficial blood flow quantification. LSI is normally performed in a mounted configuration to decrease the likelihood of motion artifact. However, mounted LSI systems are cumbersome and difficult to transport quickly in a clinical setting for which portability is essential in providing bedside patient care. To address this issue, we created a handheld LSI device using scientific grade components. To account for motion artifact of the LSI device used in a handheld setup, we incorporated a fiducial marker (FM) into our imaging protocol and determined the difference between highest and lowest speckle contrast values for the FM within each data set (Kbest and Kworst). The difference between Kbest and Kworst in mounted and handheld setups was 8% and 52%, respectively, thereby reinforcing the need for motion artifact quantification. When using a threshold FM speckle contrast value (KFM) to identify a subset of images with an acceptable level of motion artifact, mounted and handheld LSI measurements of speckle contrast of a flow region (KFLOW) in in vitro flow phantom experiments differed by 8%. Without the use of the FM, mounted and handheld KFLOW values differed by 20%. To further validate our handheld LSI device, we compared mounted and handheld data from an in vivo porcine burn model of superficial and full thickness burns. The speckle contrast within the burn region (KBURN) of the mounted and handheld LSI data differed by burns. Collectively, our results suggest the potential of handheld LSI with an FM as a suitable alternative to mounted LSI, especially in challenging clinical settings with space limitations such as the intensive care unit.

  18. Applying the neutron scatter camera to treaty verification and warhead monitoring

    International Nuclear Information System (INIS)

    Cooper, Robert Lee; Gerling, Mark; Brennan, James S.; Mascarenhas, Nicholas; Mrowka, Stanley; Marleau, Peter

    2010-01-01

    The neutron scatter camera was originally developed for a range of SNM detection applications. We are now exploring the feasibility of applications in treaty verification and warhead monitoring using experimentation, maximum likelihood estimation method (MLEM), detector optimization, and MCNP-PoliMi simulations.

  19. Use of a hand-held bladder ultrasound scanner in the assessment of dehydration and monitoring response to treatment in a paediatric emergency department.

    Science.gov (United States)

    Enright, Kevin; Beattie, Tom; Taheri, Sepideh

    2010-10-01

    Dehydration is a common concern in paediatric emergency care. Limited tools are available to assess reduced urine production, which is commonly cited as a reliable marker of dehydration. To evaluate the utility of a hand-held bladder ultrasound scanner in monitoring urine production in children attending the emergency department with suspected dehydration. A prospective pilot study was undertaken on a convenience sample of patients presenting with suspected dehydration. Serial bladder ultrasound scanning was performed to monitor urine output. Dehydration was assessed clinically using the WHO guide to dehydration assessment. Decisions about treatment and admission were made independently of the urine output measurements obtained using the bladder scanner. 45 children were studied. Using the WHO guide, 33 (73%) had mild dehydration, 8 (18%) had moderate dehydration and 4 (9%) had severe dehydration. There was a significant difference in estimated urine production between those admitted and those discharged (0.9±1.2 ml/kg/h vs 1.8±1.5 ml/kg/h, p=0.01) and between those with mild dehydration versus moderate/severe dehydration (2.3±1.5 ml/kg/h vs 0.6±0.7 ml/kg/h, p=0.0011). Urine output had been significantly reduced in those who had received an intravenous fluid bolus compared with those who had not (0.4±0.46 ml/kg/h vs 1.9±1.6 ml/kg/h, p=0.001). The hand-held bladder scanner is a convenient, non-invasive and objective adjunct in the assessment and management of children attending the emergency department with suspected dehydration.

  20. Image Quality Characteristics of Handheld Display Devices for Medical Imaging

    Science.gov (United States)

    Yamazaki, Asumi; Liu, Peter; Cheng, Wei-Chung; Badano, Aldo

    2013-01-01

    Handheld devices such as mobile phones and tablet computers have become widespread with thousands of available software applications. Recently, handhelds are being proposed as part of medical imaging solutions, especially in emergency medicine, where immediate consultation is required. However, handheld devices differ significantly from medical workstation displays in terms of display characteristics. Moreover, the characteristics vary significantly among device types. We investigate the image quality characteristics of various handheld devices with respect to luminance response, spatial resolution, spatial noise, and reflectance. We show that the luminance characteristics of the handheld displays are different from those of workstation displays complying with grayscale standard target response suggesting that luminance calibration might be needed. Our results also demonstrate that the spatial characteristics of handhelds can surpass those of medical workstation displays particularly for recent generation devices. While a 5 mega-pixel monochrome workstation display has horizontal and vertical modulation transfer factors of 0.52 and 0.47 at the Nyquist frequency, the handheld displays released after 2011 can have values higher than 0.63 at the respective Nyquist frequencies. The noise power spectra for workstation displays are higher than 1.2×10−5 mm2 at 1 mm−1, while handheld displays have values lower than 3.7×10−6 mm2. Reflectance measurements on some of the handheld displays are consistent with measurements for workstation displays with, in some cases, low specular and diffuse reflectance coefficients. The variability of the characterization results among devices due to the different technological features indicates that image quality varies greatly among handheld display devices. PMID:24236113

  1. Wireless Handhelds to Support Clinical Nursing Practicum

    Science.gov (United States)

    Wu, Cheng-Chih; Lai, Chin-Yuan

    2009-01-01

    This paper reports our implementation and evaluation of a wireless handheld learning environment used to support a clinical nursing practicum course. The learning environment was designed so that nursing students could use handhelds for recording information, organizing ideas, assessing patients, and also for interaction and collaboration with…

  2. The use of hand-held 35 mm color infrared imagery for estimates of suspended solids - A progress report. [in water pollution monitoring

    Science.gov (United States)

    Miller, W. F.; Whisler, F. D.; Robinette, H. R.; Finnie, D.; Cannon, T.

    1975-01-01

    A cost-effective aerial surveillance technique is proposed for detection and identification of suspended solids which would be operational for both governmental monitoring organizations and private individuals operating catfish farms. Sixteen catfish ponds were flown daily for seven days using two hand-held 35 mm cameras with both Kodachrome X and Ektachrome infrared film. Hue, value, and chroma designations were recorded for each pond on each date by three interpreters, and the accepted color was that recorded by at least two of the interpreters, or if there was a three hue range, the median was accepted. Relations between suspended solids and color designations were analyzed graphically, and chroma was discarded due to an apparent lack of correlation. The data obtained were then analyzed by multiple regression. Significant correlations were revealed between hue and value and total and inorganic suspended solids. If perfected, this technique could be developed to sufficent accuracy for large-scale reconnaissance surveys to monitor the quality of rivers and streams.

  3. Initial Operation of the Savannah River Site Advanced Storage Monitoring Facility

    International Nuclear Information System (INIS)

    McCurry, D.R.

    2001-01-01

    An advanced storage monitoring facility has been constructed at the Savannah River Site capable of storing sensitive nuclear materials (SNM) with access to monitoring information available over the Internet. This system will also have monitoring information available over the Internet to appropriate users. The programs will ultimately supply authenticated and encrypted data from the storage sites to certified users to demonstrate the capability of using the Internet as a safe and secure communications medium for remote monitoring of sensitive items

  4. Digital forensics for handheld devices

    CERN Document Server

    Doherty, Eamon P

    2012-01-01

    Approximately 80 percent of the world's population now owns a cell phone, which can hold evidence or contain logs about communications concerning a crime. Cameras, PDAs, and GPS devices can also contain information related to corporate policy infractions and crimes. Aimed to prepare investigators in the public and private sectors, Digital Forensics for Handheld Devices examines both the theoretical and practical aspects of investigating handheld digital devices. This book touches on all areas of mobile device forensics, including topics from the legal, technical, academic, and social aspects o

  5. ITSY Handheld Software Radio

    National Research Council Canada - National Science Library

    Bose, Vanu

    2001-01-01

    .... A handheld software radio platform would enable the construction of devices that could inter-operate with multiple legacy systems, download new waveforms and be used to construct adhoc networks...

  6. Detection of SNM by delayed gamma rays from induced fission

    International Nuclear Information System (INIS)

    Rennhofer, H.; Crochemore, J.-M.; Roesgen, E.; Pedersen, B.

    2011-01-01

    The Pulsed Neutron Interrogation Test Assembly (PUNITA) is an experimental device for research in NDA methods and field applicable instrumentation for nuclear safeguards and security applications. PUNITA incorporates a standard 14-MeV (D-T) pulsed neutron generator inside a large graphite mantle. The generator target is surrounded by a thick tungsten filter with the purpose to increase the neutron output and to tailor the neutron energy spectrum. In this configuration a sample may be exposed to a relatively high average thermal neutron flux of about (2.2±0.1)x10 3 s -1 cm -2 at only 10% of the maximum target neutron emission. The sample cavity is large enough to allow variation of the experimental setup including the fissile sample, neutron and gamma detectors, and shielding materials. The response from SNM samples of different fissile material content was investigated with various field-applicable scintillation gamma detectors such as the 3x2 in. LaBr 3 detector. Shielding in the form of tungsten and cadmium was applied to the detector to improve the signal to background ratio. Gamma and neutron shields surrounding the samples were also tested for the purpose of simulating clandestine conduct. The energy spectra of delayed gamma rays were recorded in the range 100 keV-9 MeV. In addition time spectra of delayed gamma rays in the range 3.3-8 MeV were recorded in the time period of 10 ms-120 s after the 14-MeV neutron burst. The goal of the experiment was to optimize the sample/detector configuration including the energy range and time period for SNM detection. The results show, for example, that a 170 g sample of depleted uranium can be detected with the given setup in less than 3 min of investigation. Samples of higher enrichment or higher mass are detected in much shorter time.

  7. Neutron kinetics in moderators and SNM detection through epithermal-neutron-induced fissions

    Energy Technology Data Exchange (ETDEWEB)

    Gozani, Tsahi, E-mail: tgmaven@gmail.com [1050 Harriet St., Palo Alto, CA 94301 (United States); King, Michael J. [Rapiscan Laboratories Inc., 520 Almanor Ave., Sunnyvale, CA 94085 (United States)

    2016-01-01

    Extension of the well-established Differential Die Away Analysis (DDAA) into a faster time domain, where more penetrating epithermal neutrons induce fissions, is proposed and demonstrated via simulations and experiments. In the proposed method the fissions stimulated by thermal, epithermal and even higher-energy neutrons are measured after injection of a narrow pulse of high-energy 14 MeV (d,T) or 2.5 MeV (d,D) source neutrons, appropriately moderated. The ability to measure these fissions stems from the inherent correlation of neutron energy and time (“E–T” correlation) during the process of slowing down of high-energy source neutrons in common moderating materials such as hydrogenous compounds (e.g., polyethylene), heavy water, beryllium and graphite. The kinetic behavior following injection of a delta-function-shaped pulse (in time) of 14 MeV neutrons into such moderators is studied employing MCNPX simulations and, when applicable, some simple “one-group” models. These calculations served as a guide for the design of a source moderator which was used in experiments. Qualitative relationships between slowing-down time after the pulse and the prevailing neutron energy are discussed. A laboratory system consisting of a 14 MeV neutron generator, a polyethylene-reflected Be moderator, a liquid scintillator with pulse-shape discrimination (PSD) and a two-parameter E–T data acquisition system was set up to measure prompt neutron and delayed gamma-ray fission signatures in a 19.5% enriched LEU sample. The measured time behavior of thermal and epithermal neutron fission signals agreed well with the detailed simulations. The laboratory system can readily be redesigned and deployed as a mobile inspection system for SNM in, e.g., cars and vans. A strong pulsed neutron generator with narrow pulse (<75 ns) at a reasonably high pulse frequency could make the high-energy neutron induced fission modality a realizable SNM detection technique.

  8. Introduction of handheld computing to a family practice residency program.

    Science.gov (United States)

    Rao, Goutham

    2002-01-01

    Handheld computers are valuable practice tools. It is important for residency programs to introduce their trainees and faculty to this technology. This article describes a formal strategy to introduce handheld computing to a family practice residency program. Objectives were selected for the handheld computer training program that reflected skills physicians would find useful in practice. TRGpro handheld computers preloaded with a suite of medical reference programs, a medical calculator, and a database program were supplied to participants. Training consisted of four 1-hour modules each with a written evaluation quiz. Participants completed a self-assessment questionnaire after the program to determine their ability to meet each objective. Sixty of the 62 participants successfully completed the training program. The mean composite score on quizzes was 36 of 40 (90%), with no significant differences by level of residency training. The mean self-ratings of participants across all objectives was 3.31 of 4.00. Third-year residents had higher mean self-ratings than others (mean of group, 3.62). Participants were very comfortable with practical skills, such as using drug reference software, and less comfortable with theory, such as knowing the different types of handheld computers available. Structured training is a successful strategy for introducing handheld computing to a residency program.

  9. Navigating on handheld displays: Dynamic versus Static Keyhole Navigation

    NARCIS (Netherlands)

    Mehra, S.; Werkhoven, P.; Worring, M.

    2006-01-01

    Handheld displays leave little space for the visualization and navigation of spatial layouts representing rich information spaces. The most common navigation method for handheld displays is static peephole navigation: The peephole is static and we move the spatial layout behind it (scrolling). A

  10. Doctors' experience with handheld computers in clinical practice: qualitative study.

    Science.gov (United States)

    McAlearney, Ann Scheck; Schweikhart, Sharon B; Medow, Mitchell A

    2004-05-15

    To examine doctors' perspectives about their experiences with handheld computers in clinical practice. Qualitative study of eight focus groups consisting of doctors with diverse training and practice patterns. Six practice settings across the United States and two additional focus group sessions held at a national meeting of general internists. 54 doctors who did or did not use handheld computers. Doctors who used handheld computers in clinical practice seemed generally satisfied with them and reported diverse patterns of use. Users perceived that the devices helped them increase productivity and improve patient care. Barriers to use concerned the device itself and personal and perceptual constraints, with perceptual factors such as comfort with technology, preference for paper, and the impression that the devices are not easy to use somewhat difficult to overcome. Participants suggested that organisations can help promote handheld computers by providing advice on purchase, usage, training, and user support. Participants expressed concern about reliability and security of the device but were particularly concerned about dependency on the device and over-reliance as a substitute for clinical thinking. Doctors expect handheld computers to become more useful, and most seem interested in leveraging (getting the most value from) their use. Key opportunities with handheld computers included their use as a stepping stone to build doctors' comfort with other information technology and ehealth initiatives and providing point of care support that helps improve patient care.

  11. Handheld spectrometers: the state of the art

    Science.gov (United States)

    Crocombe, Richard A.

    2013-05-01

    "Small" spectrometers fall into three broad classes: small versions of laboratory instruments, providing data, subsequently processed on a PC; dedicated analyzers, providing actionable information to an individual operator; and process analyzers, providing quantitative or semi-quantitative information to a process controller. The emphasis of this paper is on handheld dedicated analyzers. Many spectrometers have historically been large, possible fragile, expensive and complicated to use. The challenge over the last dozen years, as instruments have moved into the field, has been to make spectrometers smaller, affordable, rugged, easy-to-use, but most of all capable of delivering actionable results. Actionable results can dramatically improve the efficiency of a testing process and transform the way business is done. There are several keys to this handheld spectrometer revolution. Consumer electronics has given us powerful mobile platforms, compact batteries, clearly visible displays, new user interfaces, etc., while telecomm has revolutionized miniature optics, sources and detectors. While these technologies enable miniature spectrometers themselves, actionable information has demanded the development of rugged algorithms for material confirmation, unknown identification, mixture analysis and detection of suspicious materials in unknown matrices. These algorithms are far more sophisticated than the `correlation' or `dot-product' methods commonly used in benchtop instruments. Finally, continuing consumer electronics advances now enable many more technologies to be incorporated into handheld spectrometers, including Bluetooth, wireless, WiFi, GPS, cameras and bar code readers, and the continued size shrinkage of spectrometer `engines' leads to the prospect of dual technology or `hyphenated' handheld instruments.

  12. MPC and A operational monitoring system pilot project at MEPhI as example of successful application in the international/national control and guaranties programs

    International Nuclear Information System (INIS)

    Ryzhukhin, D.V.; Bondarev, P.V.; Pogozhin, N.S.

    2002-01-01

    Full text: At present an active development of digital communication technologies has resulted in reduction of their cost and increase of their possibilities. As a result the remote monitoring systems gain new development. The increase of the requirements to a safety level on potentially dangerous and very important objects makes such systems extremely attractive for using in a system of national departmental or international control and inspections. Purpose of using such systems is to provide control for correctness of subject to the control-regulated procedures performance, performance of management or inspection bodies' instructions and operating of existing protection systems, at integration with them. This control is independent from object staff. The remote monitoring systems usage by supervising bodies at an object gives following advantages: timely reception of information; increase of information volume at the expense of constant non physically presence of an onsite inspector; increase of received information objectivity at the expense of the fact of 'undeclared inspections' realization; an opportunity of application modern information technologies for analysis and storage of digital information; reduction of impact on object's work; reduction of volume of physical inspections and expenses for their realization. All above was reflected in the material protect, control and accounting (MPC and A) operational monitoring (MOM) program, begun under Russian-American cooperation in the field of MPC and A in 2001. MOM program purpose is to control double application materials and radioactive divided materials, activity of the people under MPC and A program and procedures ensuring performance of guarantees on special nuclear material (SNM) protection and non-proliferation. The Moscow engineering-physics institute (state university) (MEPhl) was chosen as an object of realization of MOM system pilot project. The reasons are that MEPhl is installed under framework of

  13. Glass fiber sensors for detecting special nuclear materials at portal and monitor stations

    International Nuclear Information System (INIS)

    Hull, C.D.; Seymour, R.; Crawford, T.; Bliss, M.; Craig, R.A.

    2001-01-01

    Nuclear Safeguards and Security Systems LLC (NucSafe) participated in the Illicit Trafficking Radiation Assessment Program (ITRAP) recently conducted by the Austrian Research Center, Seibersdorf (ARCS) for IAEA, INTERPOL, and the World Customs Organization (IAEA, in press). This presentation reviews ITRAP test results of NucSafe instrumentation. NucSafe produces stationary, mobile, and hand-held systems that use neutron and gamma ray sensors to detect Special Nuclear Materials (SNM). Neutron sensors are comprised of scintillating glass fibers (trade name 'PUMA' for Pu Materials Analysis), which provide several advantages over 3 He and 10 BF 3 tubes. PUMA 6 Li glass fiber sensors offer greater neutron sensitivity and dynamic counting range with significantly less microphonic susceptibility than tubes, while eliminating transport and operational hazards. PUMA sensors also cost less per active area than gas tubes, which is important since rapid neutron detection at passenger, freight, and vehicle portals require large sensor areas to provide the required sensitivity

  14. Electronic prescribing: criteria for evaluating handheld prescribing systems and an evaluation of a new, handheld, wireless wide area network (WWAN) prescribing system.

    Science.gov (United States)

    Goldblum, O M

    2001-02-01

    The objectives of this study were: 1) to establish criteria for evaluating handheld computerized prescribing systems; and 2) to evaluate out-of-box performance and features of a new, Palm Operating System (OS)-based, handheld, wireless wide area network (WWAN) prescribing system. The system consisted of a Palm Vx handheld organizer, a Novatel Minstrel V wireless modem, OmniSky wireless internet access and ePhysician ePad 1.1, the Palm OS electronic prescribing software program. A dermatologist familiar with healthcare information technology conducted an evaluation of the performance and features of a new, handheld, WWAN electronic prescribing system in an office practice during a three-month period in 2000. System performance, defined as transmission success rate, was determined from data collected during the three-month trial. Evaluation criteria consisted of an analysis of features found in electronic prescribing systems. All prescriptions written for all patients seen during a three-month period (August - November, 2000) were eligible for inclusion. Prescriptions written for patients who intended to fill them at pharmacies without known facsimile receiving capabilities were excluded from the study. The performance of the system was evaluated using data collected during the study. Criteria for evaluating features of electronic prescribing systems were developed and used to analyze the system employed in this study. During this three-month trial, 200 electronic prescriptions were generated for 132 patients included in the study. Of these prescriptions, 92.5 percent were successfully transmitted to pharmacies. Transmission failures resulted from incorrect facsimile numbers and non-functioning facsimile machines. Criteria established for evaluation of electronic prescribing systems included System (Hardware & Software), Costs, System Features, Printing & Transmission, Formulary & Insurance, Customization, Drug Safety and Security. This study is the first effort to

  15. Handheld Microfluidic Blood Ananlyzer, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Nanohmics proposes to develop a handheld blood analyzer for micro- and hypo-gravity missions. The prototype instrument will combine impedance analysis with optical...

  16. Handheld CAT Video Game, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed project is to design, develop and fabricate a handheld video game console for astronauts during long space flight. This portable hardware runs...

  17. A Cognitive Style Perspective to Handheld Devices: Customization vs. Personalization

    Science.gov (United States)

    Hsieh, Chen-Wei; Chen, Sherry Y.

    2016-01-01

    Handheld devices are widely applied to support open and distributed learning, where students are diverse. On the other hand, customization and personalization can be applied to accommodate students' diversities. However, paucity of research compares the effects of customization and personalization in the context of handheld devices. To this end, a…

  18. Driver hand-held cellular phone use: a four-year analysis.

    Science.gov (United States)

    Eby, David W; Vivoda, Jonathon M; St Louis, Renée M

    2006-01-01

    The use of hand-held cellular (mobile) phones while driving has stirred more debate, passion, and research than perhaps any other traffic safety issue in the past several years. There is ample research showing that the use of either hand-held or hands-free cellular phones can lead to unsafe driving patterns. Whether or not these performance deficits increase the risk of crash is difficult to establish, but recent studies are beginning to suggest that cellular phone use elevates crash risk. The purpose of this study was to assess changes in the rate of hand-held cellular phone use by motor-vehicle drivers on a statewide level in Michigan. This study presents the results of 13 statewide surveys of cellular phone use over a 4-year period. Hand-held cellular phone use data were collected through direct observation while vehicles were stopped at intersections and freeway exit ramps. Data were weighted to be representative of all drivers traveling during daylight hours in Michigan. The study found that driver hand-held cellular phone use has more than doubled between 2001 and 2005, from 2.7% to 5.8%. This change represents an average increase of 0.78 percentage points per year. The 5.8% use rate observed in 2005 means that at any given daylight hour, around 36,550 drivers were conversing on cellular phones while driving on Michigan roadways. The trend line fitted to these data predicts that by the year 2010, driver hand-held cellular phone use will be around 8.6%, or 55,000 drivers at any given daylight hour. These results make it clear that cellular phone use while driving will continue to be an important traffic safety issue, and highlight the importance of continued attempts to generate new ways of alleviating this potential hazard.

  19. Formation of Sn-M (M=Fe, Al, Ni) alloy nanoparticles by DC arc-discharge and their electrochemical properties as anodes for Li-ion batteries

    Science.gov (United States)

    Gao, Song; Huang, Hao; Wu, Aimin; Yu, Jieyi; Gao, Jian; Dong, Xinglong; Liu, Chunjing; Cao, Guozhong

    2016-10-01

    A direct current arc-discharge method was applied to prepare the Sn-M (M=Fe, Al, Ni) bi-alloy nanoparticles. Thermodynamic is introduced to analyze the energy circumstances for the formation of the nanoparticles during the physical condensation process. The electrochemical properties of as-prepared Sn-M alloy nanoparticles are systematically investigated as anodes of Li-ion batteries. Among them, Sn-Fe nanoparticles electrode exhibits high Coulomb efficiency (about 71.2%) in the initial charge/discharge (257.9 mA h g-1/366.6 mA h g-1) and optimal cycle stability (a specific reversible capacity of 240 mA h g-1 maintained after 20 cycles) compared with others. Large differences in the electrochemical behaviors indicate that the chemical composition and microstructure of the nanoparticles determine the lithium-ion storage properties and the long-term cyclic stability during the charge/discharge process.

  20. 75 FR 27504 - Substantial Product Hazard List: Hand-Held Hair Dryers

    Science.gov (United States)

    2010-05-17

    ... immersion during their use. Section 15(a) of the CPSA defines ``substantial product hazard'' to include, a....'' Hand-held hair dryers routinely contain open-coil heating elements that are, in essence, uninsulated..., bathtub, or lavatory). The proposed rule would define ``hand-held hair dryer'' as ``an electrical...

  1. The Nuclear Car Wash: Neutron interrogation of cargo containers to detect hidden SNM

    Science.gov (United States)

    Hall, J. M.; Asztalos, S.; Biltoft, P.; Church, J.; Descalle, M.-A.; Luu, T.; Manatt, D.; Mauger, G.; Norman, E.; Petersen, D.; Pruet, J.; Prussin, S.; Slaughter, D.

    2007-08-01

    LLNL is actively involved in the development of advanced technologies for use in detecting threats in sea-going cargo containers, particularly the presence of hidden special nuclear materials (SNM). The "Nuclear Car Wash" (NCW) project presented here uses a high-energy (En ≈ 3.5-7.0 MeV) neutron probe to scan a container and then takes high-energy (Eγ ⩾ 2.5 MeV), β-delayed γ-rays emitted during the subsequent decay of any short-lived, neutron-induced fission products as a signature of fissionable material. The components of the proposed system (e.g. neutron source, gamma detectors, etc.) will be discussed along with data processing schemes, possible threat detection metrics and potential interference signals. Results from recent laboratory experiments using a prototype system at LLNL will also be presented.

  2. The Nuclear Car Wash: Neutron interrogation of cargo containers to detect hidden SNM

    International Nuclear Information System (INIS)

    Hall, J.M.; Asztalos, S.; Biltoft, P.; Church, J.; Descalle, M.-A.; Luu, T.; Manatt, D.; Mauger, G.; Norman, E.; Petersen, D.; Pruet, J.; Prussin, S.; Slaughter, D.

    2007-01-01

    LLNL is actively involved in the development of advanced technologies for use in detecting threats in sea-going cargo containers, particularly the presence of hidden special nuclear materials (SNM). The 'Nuclear Car Wash' (NCW) project presented here uses a high-energy (E n ∼ 3.5-7.0 MeV) neutron probe to scan a container and then takes high-energy (E γ ≥ 2.5 MeV), β-delayed γ-rays emitted during the subsequent decay of any short-lived, neutron-induced fission products as a signature of fissionable material. The components of the proposed system (e.g. neutron source, gamma detectors, etc.) will be discussed along with data processing schemes, possible threat detection metrics and potential interference signals. Results from recent laboratory experiments using a prototype system at LLNL will also be presented

  3. Prospective evaluation of an internet-linked handheld computer critical care knowledge access system.

    Science.gov (United States)

    Lapinsky, Stephen E; Wax, Randy; Showalter, Randy; Martinez-Motta, J Carlos; Hallett, David; Mehta, Sangeeta; Burry, Lisa; Stewart, Thomas E

    2004-12-01

    Critical care physicians may benefit from immediate access to medical reference material. We evaluated the feasibility and potential benefits of a handheld computer based knowledge access system linking a central academic intensive care unit (ICU) to multiple community-based ICUs. Four community hospital ICUs with 17 physicians participated in this prospective interventional study. Following training in the use of an internet-linked, updateable handheld computer knowledge access system, the physicians used the handheld devices in their clinical environment for a 12-month intervention period. Feasibility of the system was evaluated by tracking use of the handheld computer and by conducting surveys and focus group discussions. Before and after the intervention period, participants underwent simulated patient care scenarios designed to evaluate the information sources they accessed, as well as the speed and quality of their decision making. Participants generated admission orders during each scenario, which were scored by blinded evaluators. Ten physicians (59%) used the system regularly, predominantly for nonmedical applications (median 32.8/month, interquartile range [IQR] 28.3-126.8), with medical software accessed less often (median 9/month, IQR 3.7-13.7). Eight out of 13 physicians (62%) who completed the final scenarios chose to use the handheld computer for information access. The median time to access information on the handheld handheld computer was 19 s (IQR 15-40 s). This group exhibited a significant improvement in admission order score as compared with those who used other resources (P = 0.018). Benefits and barriers to use of this technology were identified. An updateable handheld computer system is feasible as a means of point-of-care access to medical reference material and may improve clinical decision making. However, during the study, acceptance of the system was variable. Improved training and new technology may overcome some of the barriers we

  4. An Investigation of Game-Embedded Handheld Devices to Enhance English Learning

    Science.gov (United States)

    Hung, Hui-Chun; Young, Shelley Shwu-Ching

    2015-01-01

    This study proposed and implemented a system combining the advantages of both educational games and wireless handheld technology to promote the interactive English learning in the classroom setting. An interactive English vocabulary acquisition board game was designed with the system being implemented on handheld devices. Thirty sixth-grade…

  5. Decisions at hand: a decision support system on handhelds.

    Science.gov (United States)

    Zupan, B; Porenta, A; Vidmar, G; Aoki, N; Bratko, I; Beck, J R

    2001-01-01

    One of the applications of clinical information systems is decision support. Although the advantages of utilizing such aids have never been theoretically disputed, they have been rarely used in practice. The factor that probably often limits the utility of clinical decision support systems is the need for computing power at the very site of decision making--at the place where the patient is interviewed, in discussion rooms, etc. The paper reports on a possible solution to this problem. A decision-support shell LogReg is presented, which runs on a handheld computer. A general schema for handheld-based decision support is also proposed, where decision models are developed on personal computers/workstations, encoded in XML and then transferred to handhelds, where the models are used within a decision support shell. A use case where LogReg has been applied to clinical outcome prediction in crush injury is presented.

  6. Using medical knowledge sources on handheld computers--a qualitative study among junior doctors.

    Science.gov (United States)

    Axelson, Christian; Wårdh, Inger; Strender, Lars-Erik; Nilsson, Gunnar

    2007-09-01

    The emergence of mobile computing could have an impact on how junior doctors learn. To exploit this opportunity it is essential to understand their information seeking process. To explore junior doctors' experiences of using medical knowledge sources on handheld computers. Interviews with five Swedish junior doctors. A qualitative manifest content analysis of a focus group interview followed by a qualitative latent content analysis of two individual interviews. A focus group interview showed that users were satisfied with access to handheld medical knowledge sources, but there was concern about contents, reliability and device dependency. Four categories emerged from individual interviews: (1) A feeling of uncertainty about using handheld technology in medical care; (2) A sense of security that handhelds can provide; (3) A need for contents to be personalized; (4) A degree of adaptability to make the handheld a versatile information tool. A theme was established to link the four categories together, as expressed in the Conclusion section. Junior doctors' experiences of using medical knowledge sources on handheld computers shed light on the need to decrease uncertainty about clinical decisions during medical internship, and to find ways to influence the level of self-confidence in the junior doctor's process of decision-making.

  7. Augmented Reality Simulations on Handheld Computers

    Science.gov (United States)

    Squire, Kurt; Klopfer, Eric

    2007-01-01

    Advancements in handheld computing, particularly its portability, social interactivity, context sensitivity, connectivity, and individuality, open new opportunities for immersive learning environments. This article articulates the pedagogical potential of augmented reality simulations in environmental engineering education by immersing students in…

  8. Texting while driving: is speech-based text entry less risky than handheld text entry?

    Science.gov (United States)

    He, J; Chaparro, A; Nguyen, B; Burge, R J; Crandall, J; Chaparro, B; Ni, R; Cao, S

    2014-11-01

    Research indicates that using a cell phone to talk or text while maneuvering a vehicle impairs driving performance. However, few published studies directly compare the distracting effects of texting using a hands-free (i.e., speech-based interface) versus handheld cell phone, which is an important issue for legislation, automotive interface design and driving safety training. This study compared the effect of speech-based versus handheld text entries on simulated driving performance by asking participants to perform a car following task while controlling the duration of a secondary text-entry task. Results showed that both speech-based and handheld text entries impaired driving performance relative to the drive-only condition by causing more variation in speed and lane position. Handheld text entry also increased the brake response time and increased variation in headway distance. Text entry using a speech-based cell phone was less detrimental to driving performance than handheld text entry. Nevertheless, the speech-based text entry task still significantly impaired driving compared to the drive-only condition. These results suggest that speech-based text entry disrupts driving, but reduces the level of performance interference compared to text entry with a handheld device. In addition, the difference in the distraction effect caused by speech-based and handheld text entry is not simply due to the difference in task duration. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Correlation and Agreement of Handheld Spirometry with Laboratory Spirometry in Allogeneic Hematopoietic Cell Transplant Recipients.

    Science.gov (United States)

    Cheng, Guang-Shing; Campbell, Angela P; Xie, Hu; Stednick, Zach; Callais, Cheryl; Leisenring, Wendy M; Englund, Janet A; Chien, Jason W; Boeckh, Michael

    2016-05-01

    Early detection of subclinical lung function decline may help identify allogeneic hematopoietic cell transplant (HCT) recipients who are at increased risk for late noninfectious pulmonary complications, including bronchiolitis obliterans syndrome. We evaluated the use of handheld spirometry in this population. Allogeneic HCT recipients enrolled in a single-center observational trial performed weekly spirometry with a handheld spirometer for 1 year after transplantation. Participants performed pulmonary function tests in an outpatient laboratory setting at 3 time points: before transplantation, at day 80 after transplantation, and at 1 year after transplantation. Correlation between the 2 methods was assessed by Pearson and Spearman correlations; agreement was assessed using Bland-Altman plots. A total of 437 subjects had evaluable pulmonary function tests. Correlation for forced expiratory volume in 1 second (FEV1) was r = .954 (P spirometry correlated well with laboratory spirometry after allogeneic HCT and may be useful for self-monitoring of patients for early identification of airflow obstruction. Copyright © 2016 American Society for Blood and Marrow Transplantation. All rights reserved.

  10. Improving car passengers' comfort and experience by supporting the use of handheld devices.

    Science.gov (United States)

    van Veen, S A T; Hiemstra-van Mastrigt, S; Kamp, I; Vink, P

    2014-01-01

    There is a demand for interiors to support other activities in a car than controlling the vehicle. Currently, this is the case for the car passengers and--in the future--autonomous driving cars will also facilitate drivers to perform other activities. One of these activities is working with handheld devices. Previous research shows that people experience problems when using handheld devices in a moving vehicle and the use of handheld devices generally causes unwanted neck flexion [Young et al. 2012; Sin and Zu 2011; Gold et al.2011]. In this study, armrests are designed to support the arms when using handheld devices in a driving car in order to decrease neck flexion. Neck flexion was measured by attaching markers on the C7 and tragus. Discomfort was indicated on a body map on a scale 1-10. User experience was evaluated in a semi-structured interview. Neck flexion is significantly decreased by the support of the armrests and approaches a neutral position. Furthermore, overall comfort and comfort in the neck region specifically are significantly increased. Subjects appreciate the body posture facilitated by the armrests and 9 out of 10 prefer using handheld devices with the armrests compared to using handheld devices without the armrests. More efforts are needed to develop the mock-up into an established product, but the angles and dimensions presented in this study could serve as guidelines.

  11. Ultrasonography with a hand-held device for the diagnosis of acute appendicitis

    International Nuclear Information System (INIS)

    Kameda, Toru; Takahashi, Isao

    2009-01-01

    The purpose of this study was to evaluate the accuracy of ultrasonography (US) with a hand-held device for the diagnosis of acute appendicitis in the emergency room. US with a hand-held device was performed by the first author in 33 patients suspected of having appendicitis in the emergency room. From these 33 patients, 24 who subsequently underwent computed tomography (CT) or surgery were included in this study. The accuracy of US with the hand-held device for the diagnosis of acute appendicitis was evaluated based on the findings of CT or surgery. CT and surgery were performed in 22 and 12 patients, respectively. Final diagnoses were acute appendicitis (n=18), terminal ileitis (n=2), pelvic inflammatory disease (n=2), diverticulitis (n=1), and ureterolithiasis (n=1). The US yielded a sensitivity of 78% and a positive predictive value of 100%. The shortest distance between the abdominal wall and the appendix measured on CT was less than 40 mm in 11 patients. In ten (91%) of the 11 patients US with the hand-held device showed the swollen appendix. US with a hand-held device is potentially useful in the positive identification of acute appendicitis, but further investigation is needed to prove its utility in the routine diagnosis of acute appendicitis. (author)

  12. Introducing handheld computing into a residency program: preliminary results from qualitative and quantitative inquiry.

    OpenAIRE

    Manning, B.; Gadd, C. S.

    2001-01-01

    Although published reports describe specific handheld computer applications in medical training, we know very little yet about how, and how well, handheld computing fits into the spectrum of information resources available for patient care and physician training. This paper reports preliminary quantitative and qualitative results from an evaluation study designed to track changes in computer usage patterns and computer-related attitudes before and after introduction of handheld computing. Pre...

  13. A Continuous Automated Vault Inventory System (CAVIS) for accountability monitoring of stored nuclear materials

    International Nuclear Information System (INIS)

    Pickett, C.A.; Barham, M.A.; Gafford, T.A.; Hutchinson, D.P.; Jordan, J.K.; Maxey, L.C.; Moran, B.W.; Muhs, J.; Nodine, R.; Simpson, M.L.

    1994-01-01

    Nearly all facilities that store hazardous (radioactive or non-radioactive) materials must comply with prevailing federal, state, and local laws. These laws usually have components that require periodic physical inspections to insure that all materials remain safely and securely stored. The inspections are generally labor intensive, slow, put personnel at risk, and only find anomalies after they have occurred. The system described in this paper was developed for monitoring stored nuclear materials resulting from weapons dismantlement, but its applications extend to any storage facility that meets the above criteria. The traditional special nuclear material (SNM) accountability programs, that are currently used within most of the Department of Energy (DOE) complex, require the physical entry of highly trained personnel into SNM storage vaults. This imposes the need for additional security measures, which typically mandate that extra security personnel be present while SNM inventories are performed. These requirements increase labor costs and put additional personnel at risk to radiation exposure. In some cases, individuals have received radiation exposure equivalent to the annual maximum during just one inventory verification. With increasing overhead costs, the current system is rapidly becoming too expensive to operate, the need for an automated method of inventory verification is evident. The Continuous Automated Vault Inventory System (CAVIS) described in this paper was designed and prototyped as a low cost, highly reliable, and user friendly system that is capable of providing, real-time weight, gamma. and neutron energy confirmation from each item stored in a SNM vault. This paper describes the sensor technologies, the CAVIS prototype system (built at Y- 12 for highly enriched uranium storage), the technical requirements that must be achieved to assure successful implementation, and descriptions of sensor technologies needed for a plutonium facility

  14. A Continuous Automated Vault Inventory System (CAVIS) for accountability monitoring of stored nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Pickett, C.A.; Barham, M.A.; Gafford, T.A.; Hutchinson, D.P.; Jordan, J.K.; Maxey, L.C.; Moran, B.W.; Muhs, J.; Nodine, R.; Simpson, M.L. [and others

    1994-12-08

    Nearly all facilities that store hazardous (radioactive or non-radioactive) materials must comply with prevailing federal, state, and local laws. These laws usually have components that require periodic physical inspections to insure that all materials remain safely and securely stored. The inspections are generally labor intensive, slow, put personnel at risk, and only find anomalies after they have occurred. The system described in this paper was developed for monitoring stored nuclear materials resulting from weapons dismantlement, but its applications extend to any storage facility that meets the above criteria. The traditional special nuclear material (SNM) accountability programs, that are currently used within most of the Department of Energy (DOE) complex, require the physical entry of highly trained personnel into SNM storage vaults. This imposes the need for additional security measures, which typically mandate that extra security personnel be present while SNM inventories are performed. These requirements increase labor costs and put additional personnel at risk to radiation exposure. In some cases, individuals have received radiation exposure equivalent to the annual maximum during just one inventory verification. With increasing overhead costs, the current system is rapidly becoming too expensive to operate, the need for an automated method of inventory verification is evident. The Continuous Automated Vault Inventory System (CAVIS) described in this paper was designed and prototyped as a low cost, highly reliable, and user friendly system that is capable of providing, real-time weight, gamma. and neutron energy confirmation from each item stored in a SNM vault. This paper describes the sensor technologies, the CAVIS prototype system (built at Y- 12 for highly enriched uranium storage), the technical requirements that must be achieved to assure successful implementation, and descriptions of sensor technologies needed for a plutonium facility.

  15. 40 CFR 90.129 - Fuel tank permeation from handheld engines and equipment.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Fuel tank permeation from handheld... KILOWATTS Emission Standards and Certification Provisions § 90.129 Fuel tank permeation from handheld... equipment with respect to fuel tanks. For the purposes of this section, fuel tanks do not include fuel caps...

  16. Possible Radiation-Induced Damage to the Molecular Structure of Wooden Artifacts Due to Micro-Computed Tomography, Handheld X-Ray Fluorescence, and X-Ray Photoelectron Spectroscopic Techniques

    Directory of Open Access Journals (Sweden)

    Madalena Kozachuk

    2016-05-01

    Full Text Available This study was undertaken to ascertain whether radiation produced by X-ray photoelectron spectroscopy (XPS, micro-computed tomography (μCT and/or portable handheld X-ray fluorescence (XRF equipment might damage wood artifacts during analysis. Changes at the molecular level were monitored by Fourier transform infrared (FTIR analysis. No significant changes in FTIR spectra were observed as a result of μCT or handheld XRF analysis. No substantial changes in the collected FTIR spectra were observed when XPS analytical times on the order of minutes were used. However, XPS analysis collected over tens of hours did produce significant changes in the FTIR spectra.

  17. Handheld computers in nursing education: PDA pilot project.

    Science.gov (United States)

    Koeniger-Donohue, Rebecca

    2008-02-01

    Interest in the use and application of handheld technology at undergraduate and graduate nursing programs across the country is growing rapidly. Personal digital assistants (PDAs) are often referred to as a "peripheral brain" because they can save time, decrease errors, and simplify information retrieval at the point of care. In addition, research results support the notion that PDAs enhance nursing clinical education and are an effective student learning resource. However, most nursing programs lack the full range of technological resources to implement and provide ongoing support for handheld technology use by faculty and students. This article describes a 9-month pilot project for the initial use of PDAs by novice faculty and students at Simmons College.

  18. Handheld ESPI-speckle interferometer

    DEFF Research Database (Denmark)

    Skov Hansen, René

    2003-01-01

    . The interferometer presented here is a compact version of the set-up, Which is capable of measuring displacements of small objects, having either a specularly reflecting-or a diffusely scattering surface. The small optical set-up together with the use of the popular USB-communication for acquiring the images...... and controlling the phase of the reference wave constitutes a compact "handheld" instrument and eliminates the need for installing extra hardware, such as frame grabber and Digital to Analog converter, in the host computer....

  19. Radiation portal evaluation parameters

    International Nuclear Information System (INIS)

    York, R.L.

    1998-01-01

    The detection of the unauthorized movement of radioactive materials is one of the most effective nonproliferation measures. Automatic special nuclear material (SNM) portal monitors are designed to detect this unauthorized movement and are an important part of the safeguard systems at US nuclear facilities. SNM portals differ from contamination monitors because they are designed to have high sensitivity for the low energy gamma-rays associated with highly enriched uranium (HEU) and plutonium. These instruments are now being installed at international borders to prevent the spread of radioactive contamination an SNM. In this paper the parameters important to evaluating radiation portal monitors are discussed. (author)

  20. Who’s That Girl? Handheld Augmented Reality for Printed Photo Books

    OpenAIRE

    Henze , Niels; Boll , Susanne

    2011-01-01

    Part 1: Long and Short Papers; International audience; Augmented reality on mobile phones has recently made major progress. Lightweight, markerless object recognition and tracking makes handheld Augmented Reality feasible for new application domains. As this field is technology driven the interface design has mostly been neglected. In this paper we investigate visualization techniques for augmenting printed documents using handheld Augmented Reality. We selected the augmentation of printed ph...

  1. Energy Cost of Active and Sedentary Music Video Games: Drum and Handheld Gaming vs. Walking and Sitting.

    Science.gov (United States)

    Miranda, Edwin; Overstreet, Brittany S; Fountain, William A; Gutierrez, Vincent; Kolankowski, Michael; Overstreet, Matthew L; Sapp, Ryan M; Wolff, Christopher A; Mazzetti, Scott A

    2017-01-01

    To compare energy expenditure during and after active and handheld video game drumming compared to walking and sitting. Ten experienced, college-aged men performed four protocols (one per week): no-exercise seated control (CTRL), virtual drumming on a handheld gaming device (HANDHELD), active drumming on drum pads (DRUM), and walking on a treadmill at ~30% of VO 2max (WALK). Protocols were performed after an overnight fast, and expired air was collected continuously during (30min) and after (30min) exercise. DRUM and HANDHELD song lists, day of the week, and time of day were identical for each participant. Significant differences (p DRUM > HANDHELD. No significant differences in the rates of energy expenditure among groups during recovery were observed. Total energy expenditure was significantly greater (p < 0.05) during WALK (149.5 ± 30.6 kcal) compared to DRUM (118.7 ± 18.8 kcal) and HANDHELD (44.9±11.6 kcal), and greater during DRUM compared to HANDHELD. Total energy expenditure was not significantly different between HANDHELD (44.9 ± 11.6 kcal) and CTRL (38.2 ± 6.0 kcal). Active video game drumming at expert-level significantly increased energy expenditure compared to handheld, but it hardly met moderate-intensity activity standards, and energy expenditure was greatest during walking. Energy expenditure with handheld video game drumming was not different from no-exercise control. Thus, traditional aerobic exercise remains at the forefront for achieving the minimum amount and intensity of physical activity for health, individuals desiring to use video games for achieving weekly physical activity recommendations should choose games that require significant involvement of lower-body musculature, and time spent playing sedentary games should be a limited part of an active lifestyle.

  2. Active case finding strategy for chronic obstructive pulmonary disease with handheld spirometry.

    Science.gov (United States)

    Kim, Joo Kyung; Lee, Chang Min; Park, Ji Young; Kim, Joo Hee; Park, Sung-Hoon; Jang, Seung Hun; Jung, Ki-Suck; Yoo, Kwang Ha; Park, Yong Bum; Rhee, Chin Kook; Kim, Deog Kyeom; Hwang, Yong Il

    2016-12-01

    The early detection and diagnosis of chronic obstructive pulmonary disease (COPD) is critical to providing appropriate and timely treatment. We explored a new active case-finding strategy for COPD using handheld spirometry.We recruited subjects over 40 years of age with a smoking history of more than 10 pack-years who visited a primary clinic complaining of respiratory symptoms. A total of 190 of subjects were enrolled. Medical information was obtained from historical records and physical examination by general practitioners. All subjects had their pulmonary function evaluated using handheld spirometry with a COPD-6 device. Because forced expiratory volume in 6 seconds (FEV6) has been suggested as an alternative to FVC, we measured forced expiratory volume in 1 second (FEV1)/FEV6 for diagnosis of airflow limitation. All subjects were then referred to tertiary referral hospitals to complete a "Could it be COPD?" questionnaire, handheld spiromtery, and conventional spirometry. The results of each instrument were compared to evaluate the efficacy of both handheld spirometry and the questionnaire.COPD was newly diagnosed in 45 (23.7%) patients. According to our receiver-operating characteristic (ROC) curve analysis, sensitivity and specificity were maximal when the FEV1/FEV6 ratio was less than 77%. The area under the ROC curve was 0.759. The sensitivity, specificity, positive predictive value, and negative predictive value were 72.7%, 77.1%, 50%, and 90%, respectively. The area under the ROC curve of respiratory symptoms listed on the questionnaire ranged from 0.5 to 0.65, which indicates that there is almost no difference compared with the results of handheld spirometry.The present study demonstrated the efficacy of handheld spirometry as an active case-finding tool for COPD in a primary clinical setting. This study suggested that physicians should recommend handheld spirometry for people over the age of 40, who have a smoking history of more than 10 pack

  3. Handheld single photon emission computed tomography (handheld SPECT) navigated video-assisted thoracoscopic surgery of computer tomography-guided radioactively marked pulmonary lesions.

    Science.gov (United States)

    Müller, Joachim; Putora, Paul Martin; Schneider, Tino; Zeisel, Christoph; Brutsche, Martin; Baty, Florent; Markus, Alexander; Kick, Jochen

    2016-09-01

    Radioactive marking can be a valuable extension to minimally invasive surgery. The technique has been clinically applied in procedures involving sentinel lymph nodes, parathyroidectomy as well as interventions in thoracic surgery. Improvements in equipment and techniques allow one to improve the limits. Pulmonary nodules are frequently surgically removed for diagnostic or therapeutic reasons; here video-assisted thoracoscopic surgery (VATS) is the preferred technique. VATS might be impossible with nodules that are small or located deep in the lung. In this study, we examined the clinical application and safety of employing the newly developed handheld single photon emission tomography (handheld SPECT) device in combination with CT-guided radioactive marking of pulmonary nodules. In this pilot study, 10 subjects requiring surgical resection of a pulmonary nodule were included. The technique involved CT-guided marking of the target nodule with a 20-G needle, with subsequent injection of 25-30 MBq (effective: 7-14 MBq) Tc-99m MAA (Macro Albumin Aggregate). Quality control was made with conventional SPECT-CT to confirm the correct localization and exclude possible complications related to the puncture procedure. VATS was subsequently carried out using the handheld SPECT to localize the radioactivity intraoperatively and therefore the target nodule. A 3D virtual image was superimposed on the intraoperative visual image for surgical guidance. In 9 of the 10 subjects, the radioactive application was successfully placed directly in or in the immediate vicinity of the target nodule. The average size of the involved nodules was 9 mm (range 4-15). All successfully marked nodules were subsequently completely excised (R0) using VATS. The procedure was well tolerated. An asymptomatic clinically insignificant pneumothorax occurred in 5 subjects. Two subjects were found to have non-significant discrete haemorrhage in the infiltration canal of the needle. In a single subject, the

  4. Survey of special nuclear material vehicle monitors for domestic and international safeguards

    International Nuclear Information System (INIS)

    Fehlau, P.E.; Atwater, H.F.; Caldwell, J.T.; Shunk, E.R.

    1979-01-01

    Special nuclear materials vehicle monitors, including gateside vehicle monitors, hand-held personnel-vehicle monitors, and a new tunnel monitor concept for very large vehicles, are discussed. The results of a comparison of effectiveness of monitors for domestic application are presented. The results of calculations and small scale prototype measurements are given for a tunnel-like neutron monitor for monitoring at the perimeter of an enrichment plant subjected to International Safeguards

  5. Position statement on use of hand-held portable dental X-ray equipment

    International Nuclear Information System (INIS)

    2014-06-01

    The position statement focuses on justification in the medical field, in particular on the use of hand-held portable dental x-ray equipment. It supplements another HERCA position paper, providing a general overview of the use of all hand-held portable X-ray equipment. Key Messages: - HERCA finds that the use of hand-held portable X-ray devices should be discouraged except in special circumstances. - As a general rule, these devices should only be used in scenarios where an intraoral radiograph is deemed necessary for a patient and the use of a fixed or semi-mobile x-ray unit is impractical, e.g.: - nursing homes, residential care facilities or homes for persons with disabilities; - forensic odontology, - military operations abroad without dental facilities

  6. Carbonaceous species emitted from handheld two-stroke engines

    Science.gov (United States)

    Volckens, John; Olson, David A.; Hays, Michael D.

    Small, handheld two-stroke engines used for lawn and garden work (e.g., string trimmers, leaf blowers, etc.) can emit a variety of potentially toxic carbonaceous air pollutants. Yet, the emissions effluents from these machines go largely uncharacterized, constraining the proper development of human exposure estimates, emissions inventories, and climate and air quality models. This study samples and evaluates chemical pollutant emissions from the dynamometer testing of six small, handheld spark-ignition engines—model years 1998-2002. Four oil-gas blends were tested in each engine in duplicate. Emissions of carbon dioxide, carbon monoxide, and gas-phase hydrocarbons were predominant, and the PM emitted was organic matter primarily. An ANOVA model determined that engine type and control tier contributed significantly to emissions variations across all identified compound classes; whereas fuel blend was an insignificant variable accounting for engines were generally intermediate in magnitude compared with other gasoline-powered engines, numerous compounds traditionally viewed as motor vehicle markers are also present in small engine emissions in similar relative proportions. Given that small, handheld two-stroke engines used for lawn and garden work account for 5-10% of total US emissions of CO, CO 2, NO x, HC, and PM 2.5, source apportionment models and human exposure studies need to consider the effect of these small engines on ambient concentrations in air polluted environments.

  7. A smartphone controlled handheld microfluidic liquid handling system.

    Science.gov (United States)

    Li, Baichen; Li, Lin; Guan, Allan; Dong, Quan; Ruan, Kangcheng; Hu, Ronggui; Li, Zhenyu

    2014-10-21

    Microfluidics and lab-on-a-chip technologies have made it possible to manipulate small volume liquids with unprecedented resolution, automation and integration. However, most current microfluidic systems still rely on bulky off-chip infrastructures such as compressed pressure sources, syringe pumps and computers to achieve complex liquid manipulation functions. Here, we present a handheld automated microfluidic liquid handling system controlled by a smartphone, which is enabled by combining elastomeric on-chip valves and a compact pneumatic system. As a demonstration, we show that the system can automatically perform all the liquid handling steps of a bead-based HIV1 p24 sandwich immunoassay on a multi-layer PDMS chip without any human intervention. The footprint of the system is 6 × 10.5 × 16.5 cm, and the total weight is 829 g including battery. Powered by a 12.8 V 1500 mAh Li battery, the system consumed 2.2 W on average during the immunoassay and lasted for 8.7 h. This handheld microfluidic liquid handling platform is generally applicable to many biochemical and cell-based assays requiring complex liquid manipulation and sample preparation steps such as FISH, PCR, flow cytometry and nucleic acid sequencing. In particular, the integration of this technology with read-out biosensors may help enable the realization of the long-sought Tricorder-like handheld in vitro diagnostic (IVD) systems.

  8. Injection-depth-locking axial motion guided handheld micro-injector using CP-SSOCT.

    Science.gov (United States)

    Cheon, Gyeong Woo; Huang, Yong; Kwag, Hye Rin; Kim, Ki-Young; Taylor, Russell H; Gehlbach, Peter L; Kang, Jin U

    2014-01-01

    This paper presents a handheld micro-injector system using common-path swept source optical coherence tomography (CP-SSOCT) as a distal sensor with highly accurate injection-depth-locking. To achieve real-time, highly precise, and intuitive freehand control, the system used graphics processing unit (GPU) to process the oversampled OCT signal with high throughput and a smart customized motion monitoring control algorithm. A performance evaluation was conducted with 60-insertions and fluorescein dye injection tests to show how accurately the system can guide the needle and lock to the target depth. The evaluation tests show our system can guide the injection needle into the desired depth with 4.12 um average deviation error while injecting 50 nl of fluorescein dye.

  9. A neutron portal monitor for vehicles

    International Nuclear Information System (INIS)

    Coop, K.L.; Fehlau, P.E.; Atwater, H.F.

    1987-01-01

    We have designed and built a portal vehicle monitoring systems for detecting neutron-emitting special nuclear material (SNM) such as plutonium. Monte Carlo calculations were used to optimize the design of the 15-cm-deep x 122-cm-high x 244-cm-long detector chambers, which utilize 3 He proportional counters inside a hollow polyethylene box. Results for a variety of parametric studies, including polyethylene thickness and detector number, are described. Our experimental measurements are in good agreement with the computer calculations. The monitor's decision logic uses the Sequential Probability Ratio Test (SPRT) on Poisson distributed counting data, which is superior to other statistical tests in many applications. We performed computer simulations of the SPRT logic to determine expected false-positive decision rates. A controller unit of our design that uses this SPRT was built commercially. The cost of the complete monitoring system is similar to that of vehicle portal monitors that detect gamma rays. This new neutron monitor can serve as an addition to standard gamma-ray vehicle portals or as a stand-alone portal monitor in particular safeguards monitoring situations. The monitor is being tested at Los Alamos and is scheduled for in-plant evaluation of another DOE facility in 1987. 7 refs

  10. Handheld low-temperature plasma probe for portable "point-and-shoot" ambient ionization mass spectrometry.

    Science.gov (United States)

    Wiley, Joshua S; Shelley, Jacob T; Cooks, R Graham

    2013-07-16

    We describe a handheld, wireless low-temperature plasma (LTP) ambient ionization source and its performance on a benchtop and a miniature mass spectrometer. The source, which is inexpensive to build and operate, is battery-powered and utilizes miniature helium cylinders or air as the discharge gas. Comparison of a conventional, large-scale LTP source against the handheld LTP source, which uses less helium and power than the large-scale version, revealed that the handheld source had similar or slightly better analytical performance. Another advantage of the handheld LTP source is the ability to quickly interrogate a gaseous, liquid, or solid sample without requiring any setup time. A small, 7.4-V Li-polymer battery is able to sustain plasma for 2 h continuously, while the miniature helium cylinder supplies gas flow for approximately 8 continuous hours. Long-distance ion transfer was achieved for distances up to 1 m.

  11. Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

    Science.gov (United States)

    Ushiyama, Naoko; Kurobe, Yasushi; Momose, Kimito

    2017-11-01

    [Purpose] To determine the validity of knee extension muscle strength measurements using belt-stabilized hand-held dynamometry with and without body stabilization compared with the gold standard isokinetic dynamometry in healthy adults. [Subjects and Methods] Twenty-nine healthy adults (mean age, 21.3 years) were included. Study parameters involved right side measurements of maximal isometric knee extension strength obtained using belt-stabilized hand-held dynamometry with and without body stabilization and the gold standard. Measurements were performed in all subjects. [Results] A moderate correlation and fixed bias were found between measurements obtained using belt-stabilized hand-held dynamometry with body stabilization and the gold standard. No significant correlation and proportional bias were found between measurements obtained using belt-stabilized hand-held dynamometry without body stabilization and the gold standard. The strength identified using belt-stabilized hand-held dynamometry with body stabilization may not be commensurate with the maximum strength individuals can generate; however, it reflects such strength. In contrast, the strength identified using belt-stabilized hand-held dynamometry without body stabilization does not reflect the maximum strength. Therefore, a chair should be used to stabilize the body when performing measurements of maximal isometric knee extension strength using belt-stabilized hand-held dynamometry in healthy adults. [Conclusion] Belt-stabilized hand-held dynamometry with body stabilization is more convenient than the gold standard in clinical settings.

  12. Handheld emissions detector (HED): overview and development

    Science.gov (United States)

    Valentino, George J.; Schimmel, David

    2009-05-01

    Nova Engineering, Cincinnati OH, a division of L-3 Communications (L-3 Nova), under the sponsorship of Program Manager Soldier Warrior (PM-SWAR), Fort Belvoir, VA, has developed a Soldier portable, light-weight, hand-held, geolocation sensor and processing system called the Handheld Emissions Detector (HED). The HED is a broadband custom receiver and processor that allows the user to easily sense, direction find, and locate a broad range of emitters in the user's surrounding area. Now in its second design iteration, the HED incorporates a set of COTS components that are complemented with L-3 Nova custom RF, power, digital, and mechanical components, plus custom embedded and application software. The HED user interfaces are designed to provide complex information in a readily-understandable form, thereby providing actionable results for operators. This paper provides, where possible, the top-level characteristics of the HED as well as the rationale behind its design philosophy along with its applications in both DOD and Commercial markets.

  13. Development and testing of a scale to assess physician attitudes about handheld computers with decision support.

    Science.gov (United States)

    Ray, Midge N; Houston, Thomas K; Yu, Feliciano B; Menachemi, Nir; Maisiak, Richard S; Allison, Jeroan J; Berner, Eta S

    2006-01-01

    The authors developed and evaluated a rating scale, the Attitudes toward Handheld Decision Support Software Scale (H-DSS), to assess physician attitudes about handheld decision support systems. The authors conducted a prospective assessment of psychometric characteristics of the H-DSS including reliability, validity, and responsiveness. Participants were 82 Internal Medicine residents. A higher score on each of the 14 five-point Likert scale items reflected a more positive attitude about handheld DSS. The H-DSS score is the mean across the fourteen items. Attitudes toward the use of the handheld DSS were assessed prior to and six months after receiving the handheld device. Cronbach's Alpha was used to assess internal consistency reliability. Pearson correlations were used to estimate and detect significant associations between scale scores and other measures (validity). Paired sample t-tests were used to test for changes in the mean attitude scale score (responsiveness) and for differences between groups. Internal consistency reliability for the scale was alpha = 0.73. In testing validity, moderate correlations were noted between the attitude scale scores and self-reported Personal Digital Assistant (PDA) usage in the hospital (correlation coefficient = 0.55) and clinic (0.48), p DSS scale was reliable, valid, and responsive. The scale can be used to guide future handheld DSS development and implementation.

  14. Handheld Computers in Education: An Industry Perspective

    Science.gov (United States)

    van 't Hooft, Mark; Vahey, Philip

    2007-01-01

    Five representatives from the mobile computing industry provide their perspectives on handhelds in education. While some of their ideas differ, they all agree on the importance of staff development, appropriate curriculum development, and teacher support to create the kinds of personalized learning environments that mobile devices make possible.

  15. Handheld FRET-Aptamer Sensor for Water Safety, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Operational Technologies Corporation (OpTech) proposes to expand its current NASA Phase 2 SBIR handheld fluorometer and bone marker fluorescence resonance energy...

  16. SAFARI 2000 Atmospheric Aerosol Measurements, Hand-held Hazemeters, Zambia

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: In conjunction with the AERONET (AErosol RObotic NETwork) participation in SAFARI 2000, the USDA Forest Service deployed handheld hazemeters in western...

  17. The use of handheld radiometry for the identification of stratigraphic characteristics of Paraiba Basin units

    International Nuclear Information System (INIS)

    Souza, Ebenezer Moreno de; Villar, Heldio Pereira; Lima, Ricardo de Andrade; Lima Filho, Mario

    2000-01-01

    A study on the use of radiometric techniques for the identification of stratigraphic characteristics of Paraiba Basin units was carried out with handheld instrumentation. The area chosen ran from north Pernambuco to south Paraiba. The presence of radioactive material had been previously determined. For this work a portable scintillometer was fixed to the door of a vehicle, on the outside, with the probe directed downwards. Background radiation was measured as 40 cps (counts per second). The scintillometer has an alarm which sounds whenever the measured count rate rises above a pre-established figure, 100 cps in the present case. Monitoring then proceeded manually. In sites where the count rate was much higher than 100 cps, the probe was lowered to the soil surface. Local coordinates were obtained by GPS. Therefore, an isoradioactivity map of the area could be drawn. The comparison between this map and local geological charts showed significant correlation between observed count rates and geologic formations. Low count rates were indicative of the Barreiras formation, whereas the highest rates were obtained for the Gramame formation (with urano-phosphatic lythotypes). It is concluded that handheld radiometry is a useful tool in geological charting, is special in areas where stratigraphic units have been masked by environmental changes and human activities. (author)

  18. Design and Implementation of an Intelligent Windowsill System Using Smart Handheld Device and Fuzzy Microcontroller.

    Science.gov (United States)

    Wang, Jing-Min; Yang, Ming-Ta; Chen, Po-Lin

    2017-04-11

    With the advance of science and technology, people have a desire for convenient and comfortable living. Creating comfortable and healthy indoor environments is a major consideration for designing smart homes. As handheld devices become increasingly powerful and ubiquitous, this paper proposes an innovative use of smart handheld devices (SHD), using MIT App Inventor and fuzzy control, to perform the real-time monitoring and smart control of the designed intelligent windowsill system (IWS) in a smart home. A compact weather station that consists of environment sensors was constructed in the IWS for measuring of indoor illuminance, temperature-humidity, carbon dioxide (CO₂) concentration and outdoor rain and wind direction. According to the measured environment information, the proposed system can automatically send a command to a fuzzy microcontroller performed by Arduino UNO to fully or partly open the electric curtain and electric window for adapting to climate changes in the indoor and outdoor environment. Moreover, the IWS can automatically close windows for rain splashing on the window. The presented novel control method for the windowsill not only expands the SHD applications, but greatly enhances convenience to users. To validate the feasibility and effectiveness of the IWS, a laboratory prototype was built and confirmed experimentally.

  19. SAFARI 2000 Atmospheric Aerosol Measurements, Hand-held Hazemeters, Zambia

    Data.gov (United States)

    National Aeronautics and Space Administration — In conjunction with the AERONET (AErosol RObotic NETwork) participation in SAFARI 2000, the USDA Forest Service deployed handheld hazemeters in western Zambia from...

  20. An Intelligent Hand-Held Microsurgical Instrument for Improved Accuracy

    National Research Council Canada - National Science Library

    Ang, Wei

    2001-01-01

    This paper presents the development and initial experimental results of the first prototype of Micron, an active hand-held instrument to sense and compensate physiological tremor and other unwanted...

  1. 75 FR 8400 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-02-24

    ... Communications System Server Software, Wireless Handheld Devices and Battery Packs; Notice of Investigation... within the United States after importation of certain wireless communications system server software... certain wireless communications system server software, wireless handheld devices or battery packs that...

  2. The impact of legislation in Ireland on handheld mobile phone use by drivers.

    LENUS (Irish Health Repository)

    O'Meara, M

    2008-01-01

    Under the Road Traffic Act, 2006 handheld mobile phone use whilst driving is an offence liable to a fine and penalty points. The aim of this study was to determine whether there has been a change in driver behaviour following the introduction of this legislation. This study found that 2.3% of drivers were still using a handheld mobile phone.

  3. 75 FR 36678 - In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic...

    Science.gov (United States)

    2010-06-28

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-697] In the Matter of Certain Authentication Systems, Including Software and Handheld Electronic Devices; Notice of Commission Decision Not to... importation of certain authentication systems, including software and handheld electronic devices, by reason...

  4. My-Mini-Pet: A Handheld Pet-Nurturing Game to Engage Students in Arithmetic Practices

    Science.gov (United States)

    Liao, C. C. Y.; Chen, Z-H.; Cheng, H. N. H.; Chen, F-C.; Chan, T-W.

    2011-01-01

    In the last decade, more and more games have been developed for handheld devices. Furthermore, the popularity of handheld devices and increase of wireless computing can be taken advantage of to provide students with more learning opportunities. Games also could bring promising benefits--specifically, motivating students to learn/play, sustaining…

  5. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States.

    Science.gov (United States)

    Rudisill, Toni M; Zhu, Motao

    2017-05-12

    Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16-24, 25-59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Data from the 2008-2013 National Occupant Protection Use Survey were merged with states' cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, phone bans, the adjusted odds ratio (aOR) of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI): 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55) for males and 0.31 (CI 0.25, 0.38) for drivers in Western states compared to 0.47 (CI 0.30, 0.72) in the Northeast and 0.50 (CI 0.38, 0.66) in the South. The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  6. Accentuated Factors of Handheld Computing

    DEFF Research Database (Denmark)

    Andersson, Bo; Henningsson, Stefan

    The recent years of rapid development of mobile technologies creates opportunities for new user-groups in the mobile workforce to take advantage of in-formation systems (IS). However, to apprehend and harness these opportunities for mobile IS it is crucial to fully understand the user group and t......, these two steps develop the framework towards a theoretical contribution as theory for describing handheld computing from a designer’s perspective. Thirteen semi-structured interviews were made and the tentative framework was elaborated and confirmed....

  7. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States

    Directory of Open Access Journals (Sweden)

    Toni M. Rudisill

    2017-05-01

    Full Text Available Abstract Background Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16–24, 25–59, ≥60 years, sexes, races (White, African American, or other, ruralities (suburban, rural, or urban, and regions (Northeast, Midwest, South, and West. Methods Data from the 2008–2013 National Occupant Protection Use Survey were merged with states’ cell phone use while driving legislation. The exposure was presence of a universal hand-held cell phone ban at time of observation. Logistic regression was used to assess the odds of drivers having a hand-held cell phone conversation. Sub-groups differences were assessed using models with interaction terms. Results When universal hand-held cell phone bans were effective, hand-held cell phone conversations were lower across all driver demographic sub-groups and regions. Sub-group differences existed among the sexes (p-value, <0.0001 and regions (p-value, 0.0003. Compared to states without universal hand-held cell phone bans, the adjusted odds ratio (aOR of a driver hand-held phone conversation was 0.34 [95% confidence interval (CI: 0.28, 0.41] for females versus 0.47 (CI 0.40, 0.55 for males and 0.31 (CI 0.25, 0.38 for drivers in Western states compared to 0.47 (CI 0.30, 0.72 in the Northeast and 0.50 (CI 0.38, 0.66 in the South. Conclusions The presence of universal hand-held cell phone bans were associated lower hand-held cell phone conversations across all driver sub-groups and regions. Hand-held phone conversations were particularly lower among female drivers and those from Western states when these bans were in effect. Public health interventions concerning hand-held cell phone use while driving could reasonably target all drivers.

  8. Acute pain management efficiency improves with point-of-care handheld electronic billing system.

    Science.gov (United States)

    Fahy, Brenda G

    2009-02-01

    Technology advances continue to impact patient care and physician workflow. To enable more efficient performance of billing activities, a point-of-care (POC) handheld computer technology replaced a paper-based system on an acute pain management service. Using a handheld personal digital assistant (PDA) and software from MDeverywhere (MDe, MDeverywhere, Long Island, NY), we performed a 1-yr prospective observational study of an anesthesiology acute pain management service billings and collections. Seventeen anesthesiologists providing billable acute pain services were trained and entered their charges on a PDA. Twelve months of data, just before electronic implementation (pre-elec), were compared to a 12-m period after implementation (post-elec). The total charges were 4883 for 890 patients pre-elec and 5368 for 1128 patients post-elec. With adoption of handheld billing, the charge lag days decreased from 29.3 to 7.0 (P billing using PDAs to replace a paper-based billing system improved the collection rate and decreased the number of charge lag days with a positive return on investment. The handheld PDA billing system provided POC support for physicians during their daily clinical (e.g., patient locations, rounding lists) and billing activities, improving workflow.

  9. Epilepsy Forewarning Using A Hand-Held Device

    Energy Technology Data Exchange (ETDEWEB)

    Hively, LM

    2005-02-21

    Over the last decade, ORNL has developed and patented a novel approach for forewarning of a large variety of machine and biomedical events. The present implementation uses desktop computers to analyze archival data. This report describes the next logical step in this effort, namely use of a hand-held device for the analysis.

  10. Aristocratic Sinomania: The SNM Museum Červený Kameň and its collection of Chinese porcelain (Vplyv sinománie na budovanie šľachtických zbierok – zbierka čínskeho porcelánu v SNM-Múzeu Červený Kameň

    Directory of Open Access Journals (Sweden)

    Nikola Maliňáková

    2016-03-01

    Full Text Available This paper analyzes the influence of Chinese culture on the lifestyle of European aristocrats which ranged from adoption of certain elements from the Chinese culture to an outright Sinomania which led to such fads as designing homes in the chinoiserie style or collecting Chinese artifacts, especially porcelain. The latter not only showed that the owner followed the latest fashions, but it also displayed their wealth and high social status. In this paper, we analyzed one such collection currently house in the SNM Musem Červený Kameň providing a detailed description of selected items

  11. Clinical translation of handheld optical coherence tomography: practical considerations and recent advancements

    Science.gov (United States)

    Monroy, Guillermo L.; Won, Jungeun; Spillman, Darold R.; Dsouza, Roshan; Boppart, Stephen A.

    2017-12-01

    Since the inception of optical coherence tomography (OCT), advancements in imaging system design and handheld probes have allowed for numerous advancements in disease diagnostics and characterization of the structural and optical properties of tissue. OCT system developers continue to reduce form factor and cost, while improving imaging performance (speed, resolution, etc.) and flexibility for applicability in a broad range of fields, and nearly every clinical specialty. An extensive array of components to construct customized systems has also become available, with a range of commercial entities that produce high-quality products, from single components to full systems, for clinical and research use. Many advancements in the development of these miniaturized and portable systems can be linked back to a specific challenge in academic research, or a clinical need in medicine or surgery. Handheld OCT systems are discussed and explored for various applications. Handheld systems are discussed in terms of their relative level of portability and form factor, with mention of the supporting technologies and surrounding ecosystem that bolstered their development. Additional insight from our efforts to implement systems in several clinical environments is provided. The trend toward well-designed, efficient, and compact handheld systems paves the way for more widespread adoption of OCT into point-of-care or point-of-procedure applications in both clinical and commercial settings.

  12. Evaluation of an enclosed ultraviolet-C radiation device for decontamination of mobile handheld devices.

    Science.gov (United States)

    Mathew, J Itty; Cadnum, Jennifer L; Sankar, Thriveen; Jencson, Annette L; Kundrapu, Sirisha; Donskey, Curtis J

    2016-06-01

    Mobile handheld devices used in health care settings may become contaminated with health care-associated pathogens. We demonstrated that an enclosed ultraviolet-C radiation device was effective in rapidly reducing methicillin-resistant Staphylococcus aureus, and with longer exposure times, Clostridium difficile spores, on glass slides and reducing contamination on in-use mobile handheld devices. Published by Elsevier Inc.

  13. Agreement Between an Automated Volume Breast Scanner and Handheld Ultrasound for Diagnostic Breast Examinations.

    Science.gov (United States)

    Barr, Richard G; DeVita, Robert; Destounis, Stamatia; Manzoni, Federica; De Silvestri, Annalisa; Tinelli, Carmine

    2017-10-01

    To compare the agreement and interobserver variability of diagnostic handheld ultrasound (US) and a single volume on an automated breast volume scanner (ABVS) and to determine whether there was a significant difference if the ABVS was used by a sonographer or mammographic technologist. Ninety patients scheduled for diagnostic US examinations were randomized to either handheld US or the ABVS first. The AVBS was randomized between a sonographer and a mammographic technologist performing the study. The studies were blinded, randomized, and read by 2 radiologists. The lesion with the highest Breast Imaging Reporting and Data System (BI-RADS) score was used in the analysis. Final diagnoses were made by core biopsy or follow-up for 2 years. Lesions included 9 malignant and 81 benign. The 90 patients had a mean age ± SD of 53.1 ± 16.3 years. The κ value for agreement between the ABVS and handheld US was 0.831 (95% confidence interval, 0.744-0.925), whereas the global agreement for a 7-point BI-RADS score was 0.488 (0.372-0.560). The agreement between the ABVS and handheld US was nearly the same when the ABVS was used by a mammographic technologist (κ = 0.858 [0.723-0.963]) or sonographer (κ = 0.803 [0.596-1.000]; P = .47). The areas under the receiver operating characteristic curves for characterization by the ABVS were 0.91 (0.84-0.96) for reader 1 and 0.91 (0.83-0.96) for reader 2; those for handheld US were 0.91 (0.84-0.96) for reader 1 and 0.83 (0.74-0.90) for reader 2, with no statistical difference. The agreement based on pathologic images was κ = 0.831 (0.718-0.944); for handheld US, κ = 0.795 (0.623-0.967); and for the AVBS, κ = 0.869 (0.725-1.000). Performing a single-view diagnostic ABVS examination has good agreement with a handheld diagnostic US workup. There is no difference if the ABVS is used by a sonographer or mammographic technologist. © 2017 by the American Institute of Ultrasound in Medicine.

  14. Leakage and scattered radiation from hand-held dental x-ray unit

    International Nuclear Information System (INIS)

    Kim, Eun Kyung

    2007-01-01

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR ΙΙΙ was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR ΙΙΙ was exposed with portable X-ray unit 6.39 μGy, and the mean dose with fixed X-ray unit 3.03 μGy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 μGy and with fixed X-ray unit the mean dose was 0.68 μGy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography

  15. Leakage and scattered radiation from hand-held dental x-ray unit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Kyung [Dankook Univ. School of Dentistry, Seoul (Korea, Republic of)

    2007-06-15

    To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR {iota}{iota}{iota} was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of hand-held dental X-ray unit were 70 kVp, 3 mA , 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. The mean dose at the hand level when human skull DXTTR {iota}{iota}{iota} was exposed with portable X-ray unit 6.39 {mu}Gy, and the mean dose with fixed X-ray unit 3.03 {mu}Gy (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was 2.97 {mu}Gy and with fixed X-ray unit the mean dose was 0.68 {mu}Gy (p<0.01). The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  16. Special nuclear material simulation device

    Science.gov (United States)

    Leckey, John H.; DeMint, Amy; Gooch, Jack; Hawk, Todd; Pickett, Chris A.; Blessinger, Chris; York, Robbie L.

    2014-08-12

    An apparatus for simulating special nuclear material is provided. The apparatus typically contains a small quantity of special nuclear material (SNM) in a configuration that simulates a much larger quantity of SNM. Generally the apparatus includes a spherical shell that is formed from an alloy containing a small quantity of highly enriched uranium. Also typically provided is a core of depleted uranium. A spacer, typically aluminum, may be used to separate the depleted uranium from the shell of uranium alloy. A cladding, typically made of titanium, is provided to seal the source. Methods are provided to simulate SNM for testing radiation monitoring portals. Typically the methods use at least one primary SNM spectral line and exclude at least one secondary SNM spectral line.

  17. Handheld computers for self-administered sensitive data collection: A comparative study in Peru

    Directory of Open Access Journals (Sweden)

    Hughes James P

    2008-03-01

    Full Text Available Abstract Background Low-cost handheld computers (PDA potentially represent an efficient tool for collecting sensitive data in surveys. The goal of this study is to evaluate the quality of sexual behavior data collected with handheld computers in comparison with paper-based questionnaires. Methods A PDA-based program for data collection was developed using Open-Source tools. In two cross-sectional studies, we compared data concerning sexual behavior collected with paper forms to data collected with PDA-based forms in Ancon (Lima. Results The first study enrolled 200 participants (18–29 years. General agreement between data collected with paper format and handheld computers was 86%. Categorical variables agreement was between 70.5% and 98.5% (Kappa: 0.43–0.86 while numeric variables agreement was between 57.1% and 79.8% (Spearman: 0.76–0.95. Agreement and correlation were higher in those who had completed at least high school than those with less education. The second study enrolled 198 participants. Rates of responses to sensitive questions were similar between both kinds of questionnaires. However, the number of inconsistencies (p = 0.0001 and missing values (p = 0.001 were significantly higher in paper questionnaires. Conclusion This study showed the value of the use of handheld computers for collecting sensitive data, since a high level of agreement between paper and PDA responses was reached. In addition, a lower number of inconsistencies and missing values were found with the PDA-based system. This study has demonstrated that it is feasible to develop a low-cost application for handheld computers, and that PDAs are feasible alternatives for collecting field data in a developing country.

  18. Human Handheld-Device Interaction : An Adaptive User Interface

    NARCIS (Netherlands)

    Fitrianie, S.

    2010-01-01

    The move to smaller, lighter and more powerful (mobile) handheld devices, whe-ther PDAs or smart-phones, looks like a trend that is building up speed. With numerous embedded technologies and wireless connectivity, the drift opens up unlimited opportunities in daily activities that are both more

  19. Mobile monitoring in routine operations and emergencies

    International Nuclear Information System (INIS)

    Barth, Joachim; Bucher, Benno; Estier, Sybille

    2011-01-01

    Gaining actuality after the Fukushima accident and in a certain way complementing the main topic of the most recent issue (Emergency Preparedness), articles deal with mobile monitoring in its various aspects. Mobile laboratories and measuring devices are presented ranging from aerosol samplers in aeroplanes over helicopters, environmental monitoring cars, a fire brigades CBRN-reconnaissance vehicle and mobile in-vivo laboratories to the special van of an emergency response team carrying among others hand-held instruments. (orig.)

  20. The availability of relatively cheap hand-held Global Positioning ...

    African Journals Online (AJOL)

    spamer

    conditions, so the approach failed to produce results ... Hand-held Global Positioning System (GPS) receivers provide opportunities for detailed and rapid mapping of features ..... TICKELL, W. L. N. 1968 — The biology of the great albatrosses,.

  1. Hand-held electronic data collection and procedure environment

    International Nuclear Information System (INIS)

    Kennedy, E.; Doniz, K.

    1996-01-01

    As part of a CANDU Owners Group project, AECL has developed a hand-held electronic data collection and procedure environment. Integral to this environment is the C omputerized Procedure Engine . The development of the CPE allows operators, maintainers, and technical support staff to execute virtually any type of station procedure on a general-purpose PC-compatible hand-held computer. There are several advantages to using the computerized procedures: less paper use and handling, reduction in human error, reduction in rework in the field, an increase in procedural compliance, and immediate availability of data to download to databases and plant information systems. The paper describes: the advantages of using computerized procedures, why early forms of computerized procedures were inadequate, the features that the C omputerized Procedure Engine o ffers to the user, the streamlined life cycle of a computerized procedure, and field experience. The paper concludes that computerized procedures are ready for pilot applications at stations. (author)

  2. Handheld Universal Diagnostic Sensor

    Science.gov (United States)

    Chan, Eugene

    2012-01-01

    The rHEALTH technology is designed to shrink an entire hospital testing laboratory onto a handheld device. A physician or healthcare provider performs the test by collecting a fingerstick of blood from a patient. The tiny volume of blood is inserted into the rHEALTH device. Inside the device is a microfluidic chip that contains small channels about the width of a human hair. These channels help move the blood and analyze the blood sample. The rHEALTH sensor uses proprietary reagents called nanostrips, which are nanoscale test strips that enable the clinical assays. The readout is performed by laser-induced fluorescence. Overall, the time from blood collection through analysis is less than a minute.

  3. Monitoring around the secret nuclear facilities of naval ports

    International Nuclear Information System (INIS)

    Jaskierowicz, D.; Quere, St.

    2010-01-01

    Based within large industrial cities (Brest, Toulon, Cherbourg) or more rural areas like Crozon (Ile Longue), French navy exploits nuclear facilities where are built, maintained and decommissioned nuclear power submarines and aircraft-carrier. The safety and the security of these installations as well as the non-impact on people and environment are continuously monitored. The DSND, a governmental regulatory body dedicated to the Defense, applies the same regulations enforced by the ASN for civilian nuclear activities. Concerning environmental monitoring, the navy answers to the DSND or the ASN, depending on the type of survey. In every nuclear site, an automatic nuclear monitoring sensor system (2SNM) runs 24/7, with the supervision of specialized personnel in radioprotection. Each year, more than 7000 samples are collected in the ecosystem and thousands of measurements are carried out in four laboratories (LASEM in Cherbourg, Brest and Toulon) - SPRS ILO) of the navy. These results are sent to the DSND and have been integrated since February 2010 to the brand-new public web site of the national monitoring network of radioactivity in the environment (RMN). (author)

  4. Application of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) to Geochemical Analysis.

    Science.gov (United States)

    Connors, Brendan; Somers, Andrew; Day, David

    2016-05-01

    While laser-induced breakdown spectroscopy (LIBS) has been in use for decades, only within the last two years has technology progressed to the point of enabling true handheld, self-contained instruments. Several instruments are now commercially available with a range of capabilities and features. In this paper, the SciAps Z-500 handheld LIBS instrument functionality and sub-systems are reviewed. Several assayed geochemical sample sets, including igneous rocks and soils, are investigated. Calibration data are presented for multiple elements of interest along with examples of elemental mapping in heterogeneous samples. Sample preparation and the data collection method from multiple locations and data analysis are discussed. © The Author(s) 2016.

  5. Exploring streamwater mixing dynamics via handheld thermal infrared imagery

    NARCIS (Netherlands)

    Antonelli, Marta; Klaus, Julian; Smettem, Keith; Teuling, Ryan; Pfister, Laurent

    2017-01-01

    Stream confluences are important hotspots of aquatic ecological processes. Water mixing dynamics at stream confluences influence physio-chemical characteristics of the stream as well as sediment mobilisation and pollutant dispersal. In this study, we investigated the potential for handheld

  6. Characterizing infantile hemangiomas with a near-infrared spectroscopic handheld wireless device

    Science.gov (United States)

    Fong, Christopher J.; Hoi, Jennifer W.; Kim, Hyun K.; Behr, Gerald; Geller, Lauren; Antonov, Nina; Flexman, Molly; Garzon, Maria; Hielscher, Andreas H.

    2015-03-01

    Infantile hemangiomas (IH) are common vascular growths that occur in 5-10% of neonates and have the potential to cause disfiguring and even life-threatening complications. Currently, no objective tool exist to monitor either progression or treatment of IH. To address this unmet clinical need, we have developed a handheld wireless device (HWD) that uses diffuse optical spectroscopy for the assessment of IH. The system employs 4 wavelengths (l=780nm, 805nm, 850nm, and 905nm) and 6 source-detector pairs with distances between 0.6 and 20 mm. Placed on the skin surface, backreflection data is obtained and a multispectral evolution algorithm is used to determine total hemoglobin concentration and tissue oxygen saturation. First results of an ongoing pilot study involving 13 patients (average enrollment age = 25 months) suggest that an increase in hypoxic stress over time can lead to the proliferation of IH. Involuting IH lesions showed an increase in tissue oxygen saturation as well as a decrease in total hemoglobin.

  7. Performance of handheld electrocardiogram devices to detect atrial fibrillation in a cardiology and geriatric ward setting.

    Science.gov (United States)

    Desteghe, Lien; Raymaekers, Zina; Lutin, Mark; Vijgen, Johan; Dilling-Boer, Dagmara; Koopman, Pieter; Schurmans, Joris; Vanduynhoven, Philippe; Dendale, Paul; Heidbuchel, Hein

    2017-01-01

    To determine the usability, accuracy, and cost-effectiveness of two handheld single-lead electrocardiogram (ECG) devices for atrial fibrillation (AF) screening in a hospital population with an increased risk for AF. Hospitalized patients (n = 445) at cardiological or geriatric wards were screened for AF by two handheld ECG devices (MyDiagnostick and AliveCor). The performance of the automated algorithm of each device was evaluated against a full 12-lead or 6-lead ECG recording. All ECGs and monitor tracings were also independently reviewed in a blinded fashion by two electrophysiologists. Time investments by nurses and physicians were tracked and used to estimate cost-effectiveness of different screening strategies. Handheld recordings were not possible in 7 and 21.4% of cardiology and geriatric patients, respectively, because they were not able to hold the devices properly. Even after the exclusion of patients with an implanted device, sensitivity and specificity of the automated algorithms were suboptimal (Cardiology: 81.8 and 94.2%, respectively, for MyDiagnostick; 54.5 and 97.5%, respectively, for AliveCor; Geriatrics: 89.5 and 95.7%, respectively, for MyDiagnostick; 78.9 and 97.9%, respectively, for AliveCor). A scenario based on automated AliveCor evaluation in patients without AF history and without an implanted device proved to be the most cost-effective method, with a provider cost to identify one new AF patient of €193 and €82 at cardiology and geriatrics, respectively. The cost to detect one preventable stroke per year would be €7535 and €1916, respectively (based on average CHA 2 DS 2 -VASc of 3.9 ± 2.0 and 5.0 ± 1.5, respectively). Manual interpretation increases sensitivity, but decreases specificity, doubling the cost per detected patient, but remains cheaper than sole 12-lead ECG screening. Using AliveCor or MyDiagnostick handheld recorders requires a structured screening strategy to be effective and cost-effective in a hospital setting

  8. Accuracy of Handheld Blood Glucose Meters at High Altitude

    NARCIS (Netherlands)

    de Mol, Pieter; Krabbe, Hans G.; de Vries, Suzanna T.; Fokkert, Marion J.; Dikkeschei, Bert D.; Rienks, Rienk; Bilo, Karin M.; Bilo, Henk J. G.

    2010-01-01

    Background: Due to increasing numbers of people with diabetes taking part in extreme sports (e. g., high-altitude trekking), reliable handheld blood glucose meters (BGMs) are necessary. Accurate blood glucose measurement under extreme conditions is paramount for safe recreation at altitude. Prior

  9. A hand-held robotic device for peripheral intravenous catheterization.

    Science.gov (United States)

    Cheng, Zhuoqi; Davies, Brian L; Caldwell, Darwin G; Barresi, Giacinto; Xu, Qinqi; Mattos, Leonardo S

    2017-12-01

    Intravenous catheterization is frequently required for numerous medical treatments. However, this process is characterized by a high failure rate, especially when performed on difficult patients such as newborns and infants. Very young patients have small veins, and that increases the chances of accidentally puncturing the catheterization needle directly through them. In this article, we present the design, development and experimental evaluation of a novel hand-held robotic device for improving the process of peripheral intravenous catheterization by facilitating the needle insertion procedure. To our knowledge, this design is the first hand-held robotic device for assisting in the catheterization insertion task. Compared to the other available technologies, it has several unique advantages such as being compact, low-cost and able to reliably detect venipuncture. The system is equipped with an electrical impedance sensor at the tip of the catheterization needle, which provides real-time measurements used to supervise and control the catheter insertion process. This allows the robotic system to precisely position the needle within the lumen of the target vein, leading to enhanced catheterization success rate. Experiments conducted to evaluate the device demonstrated that it is also effective to deskill the task. Naïve subjects achieved an average catheterization success rate of 88% on a 1.5 mm phantom vessel with the robotic device versus 12% with the traditional unassisted system. The results of this work prove the feasibility of a hand-held assistive robotic device for intravenous catheterization and show that such device has the potential to greatly improve the success rate of these difficult operations.

  10. Neurosurgery contact handheld probe based on sapphire shaped crystal

    Science.gov (United States)

    Shikunova, I. A.; Stryukov, D. O.; Rossolenko, S. N.; Kiselev, A. M.; Kurlov, V. N.

    2017-01-01

    A handheld contact probe based on sapphire shaped crystal is developed for intraoperative spectrally-resolved optical diagnostics, laser coagulation and aspiration of malignant brain tissue. The technology was integrated into the neurosurgical workflow for intraoperative real-time identification and removing of invasive brain cancer.

  11. A handheld support system to facilitate stereological measurements and mapping of branching structures

    DEFF Research Database (Denmark)

    Gardi, J.E.; Wulfsohn, Dvora-Laiô; Nyengaard, J.R.

    2007-01-01

    specifications, software and Graphical User Interface (GUI) development, functionality and application of the handheld system using four examples: (1) sampling monkey lung bronchioles for estimation of diameter and wall thickness (2) sampling rat kidney for estimating number of arteries and arterioles......‘BranchSampler' is a system for computer-assisted manual stereology written for handheld devices running Windows CE. The system has been designed specifically to streamline data collection and optimize sampling of tree-like branching structures, with particular aims of reducing user errors, saving...

  12. CERN safety system monitoring - SSM

    International Nuclear Information System (INIS)

    Hakulinen, T.; Ninin, P.; Valentini, F.; Gonzalez, J.; Salatko-Petryszcze, C.

    2012-01-01

    CERN SSM (Safety System Monitoring) is a system for monitoring state-of-health of the various access and safety systems of the CERN site and accelerator infrastructure. The emphasis of SSM is on the needs of maintenance and system operation with the aim of providing an independent and reliable verification path of the basic operational parameters of each system. Included are all network-connected devices, such as PLCs (local purpose control unit), servers, panel displays, operator posts, etc. The basic monitoring engine of SSM is a freely available system-monitoring framework Zabbix, on top of which a simplified traffic-light-type web-interface has been built. The web-interface of SSM is designed to be ultra-light to facilitate access from hand-held devices over slow connections. The underlying Zabbix system offers history and notification mechanisms typical of advanced monitoring systems. (authors)

  13. Imaging Emission Spectra with Handheld and Cellphone Cameras

    Science.gov (United States)

    Sitar, David

    2012-01-01

    As point-and-shoot digital camera technology advances it is becoming easier to image spectra in a laboratory setting on a shoestring budget and get immediate results. With this in mind, I wanted to test three cameras to see how their results would differ. Two undergraduate physics students and I used one handheld 7.1 megapixel (MP) digital Cannon…

  14. Octopus: embracing the energy efficiency of handheld multimedia computers

    NARCIS (Netherlands)

    Havinga, Paul J.M.; Smit, Gerardus Johannes Maria

    1999-01-01

    In the MOBY DICK project we develop and define the architecture of a new generation of mobile hand-held computers called Mobile Digital Companions. The Companions must meet several major requirements: high performance, energy efficient, a notion of Quality of Service (QoS), small size, and low

  15. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study

    Directory of Open Access Journals (Sweden)

    Fleming Lora E

    2011-04-01

    Full Text Available Abstract Background Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. Methods In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost of the handheld administration method was recorded and compared to approaches available in the extant literature. Results Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Conclusions Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data

  16. Application of handheld devices to field research among underserved construction worker populations: a workplace health assessment pilot study.

    Science.gov (United States)

    Caban-Martinez, Alberto J; Clarke, Tainya C; Davila, Evelyn P; Fleming, Lora E; Lee, David J

    2011-04-01

    Novel low-cost approaches for conducting rapid health assessments and health promotion interventions among underserved worker groups are needed. Recruitment and participation of construction workers is particularly challenging due to their often transient periods of work at any one construction site, and their limited time during work to participate in such studies. In the present methodology report, we discuss the experience, advantages and disadvantages of using touch screen handheld devices for the collection of field data from a largely underserved worker population. In March 2010, a workplace-centered pilot study to examine the feasibility of using a handheld personal device for the rapid health assessment of construction workers in two South Florida Construction sites was undertaken. A 45-item survey instrument, including health-related questions on tobacco exposure, workplace safety practices, musculoskeletal disorders and health symptoms, was programmed onto Apple iPod Touch® devices. Language sensitive (English and Spanish) recruitment scripts, verbal consent forms, and survey questions were all preloaded onto the handheld devices. The experience (time to survey administration and capital cost) of the handheld administration method was recorded and compared to approaches available in the extant literature. Construction workers were very receptive to the recruitment, interview and assessment processes conducted through the handheld devices. Some workers even welcomed the opportunity to complete the questionnaire themselves using the touch screen handheld device. A list of advantages and disadvantages emerged from this experience that may be useful in the rapid health assessment of underserved populations working in a variety of environmental and occupational health settings. Handheld devices, which are relatively inexpensive, minimize survey response error, and allow for easy storage of data. These technological research modalities are useful in the

  17. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Directory of Open Access Journals (Sweden)

    Janson C

    2006-04-01

    Full Text Available Abstract Background Exhaled nitric oxide (NO measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO was compared with a standard stationary chemiluminescence unit (NIOX. Methods A total of 71 subjects (6–60 years; 36 males, both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots, measurement feasibility (success rate with 6 attempts and repeatability (intrasubject SD. Results Success rate was high (≥ 84% in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb. When comparing the mean of three measurements (n = 61, the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO and the stationary system (NIOX are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO is used. The hand-held device shows good repeatability, and it

  18. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    Science.gov (United States)

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children

  19. Neurosurgical hand-held optical coherence tomography (OCT) forward-viewing probe

    Science.gov (United States)

    Sun, Cuiru; Lee, Kenneth K. C.; Vuong, Barry; Cusimano, Michael; Brukson, Alexander; Mariampillai, Adrian; Standish, Beau A.; Yang, Victor X. D.

    2012-02-01

    A prototype neurosurgical hand-held optical coherence tomography (OCT) imaging probe has been developed to provide micron resolution cross-sectional images of subsurface tissue during open surgery. This new ergonomic hand-held probe has been designed based on our group's previous work on electrostatically driven optical fibers. It has been packaged into a catheter probe in the familiar form factor of the clinically accepted Bayonet shaped neurosurgical non-imaging Doppler ultrasound probes. The optical design was optimized using ZEMAX simulation. Optical properties of the probe were tested to yield an ~20 um spot size, 5 mm working distance and a 3.5 mm field of view. The scan frequency can be increased or decreased by changing the applied voltage. Typically a scan frequency of less than 60Hz is chosen to keep the applied voltage to less than 2000V. The axial resolution of the probe was ~15 um (in air) as determined by the OCT system. A custom-triggering methodology has been developed to provide continuous stable imaging, which is crucial for clinical utility. Feasibility of this probe, in combination with a 1310 nm swept source OCT system was tested and images are presented to highlight the usefulness of such a forward viewing handheld OCT imaging probe. Knowledge gained from this research will lay the foundation for developing new OCT technologies for endovascular management of cerebral aneurysms and transsphenoidal neuroendoscopic treatment of pituitary tumors.

  20. Interactive topology optimization on hand-held devices

    DEFF Research Database (Denmark)

    Aage, Niels; Nobel-Jørgensen, Morten; Andreasen, Casper Schousboe

    2013-01-01

    This paper presents an interactive topology optimization application designed for hand-held devices running iOS or Android. The TopOpt app solves the 2D minimum compliance problem with interactive control of load and support positions as well as volume fraction. Thus, it is possible to change......OS devices from the Apple App Store, at Google Play for the Android platform, and a web-version can be run from www.topopt.dtu.dk....

  1. Cellphone-based hand-held microplate reader for point-of-care ELISA testing (Conference Presentation)

    Science.gov (United States)

    Berg, Brandon; Cortazar, Bingen; Tseng, Derek; Ozkan, Haydar; Feng, Steve; Wei, Qingshan; Chan, Raymond Y.; Burbano, Jordi; Farooqui, Qamar; Lewinski, Michael; Di Carlo, Dino; Garner, Omai B.; Ozcan, Aydogan

    2016-03-01

    Enzyme-linked immunosorbent assay (ELISA) in a microplate format has been a gold standard first-line clinical test for diagnosis of various diseases including infectious diseases. However, this technology requires a relatively large and expensive multi-well scanning spectrophotometer to read and quantify the signal from each well, hindering its implementation in resource-limited-settings. Here, we demonstrate a cost-effective and handheld smartphone-based colorimetric microplate reader for rapid digitization and quantification of immunoserology-related ELISA tests in a conventional 96-well plate format at the point of care (POC). This device consists of a bundle of 96 optical fibers to collect the transmitted light from each well of the microplate and direct all the transmission signals from the wells onto the camera of the mobile-phone. Captured images are then transmitted to a remote server through a custom-designed app, and both quantitative and qualitative diagnostic results are returned back to the user within ~1 minute per 96-well plate by using a machine learning algorithm. We tested this mobile-phone based micro-plate reader in a clinical microbiology lab using FDA-approved mumps IgG, measles IgG, and herpes simplex virus IgG (HSV-1 and HSV-2) ELISA tests on 1138 remnant patient samples (roughly 50% training and 50% testing), and achieved an overall accuracy of ~99% or higher for each ELISA test. This handheld and cost-effective platform could be immediately useful for large-scale vaccination monitoring in low-infrastructure settings, and also for other high-throughput disease screening applications at POC.

  2. Hand-held and automated breast ultrasound

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.; Kimme-Smith, C.

    1985-01-01

    The book is a guide for physicians and technologists who use US as an adjunct to mammography; it carefully outlines the pros and cons of US of the breast and its role in the diagnosis of benign and malignant diseases. After an introduction that discusses the philosophy of breast US, the chapters cover the physics of US and instrumentation (both hand-held transducers as well as automated water path scanners), then proceed to a discussion of the normal breast. Sections on benign disorders, malignant lesions, and pitfalls of diagnosis are followed by quiz cases

  3. Technology-enabled division of labour: the use of handhelds

    NARCIS (Netherlands)

    Benders, J.G.J.M.; Schouteten, R.L.J.; Ruijsscher, C. de

    2012-01-01

    Using the task pool model and data from 15 establishments in the Dutch hospitality industry, this study shows how and why applying handhelds affects the division of labour. These devices allow to split the waiters' jobs into separate tasks which tend to be combined into two separate "sub jobs": the

  4. Technology-enabled division of labour : The use of handhelds

    NARCIS (Netherlands)

    Benders, J.G.J.M.; Schouteten, R.; de Ruijsscher, C.

    2012-01-01

    Using the task pool model and data from 15 establishments in the Dutch hospitality industry, this study shows how and why applying handhelds affects the division of labour. These devices allow to split the waiters' jobs into separate tasks which tend to be combined into two separate "sub jobs": the

  5. Environmental impact appraisal for renewal of Special Nuclear Material License No. SNM-1097 (Docket No. 70-1113)

    International Nuclear Information System (INIS)

    1984-06-01

    The proposed action, the full 5-year renewal of License SNM-1097, is necessary for GE to continue producing fuel used in light-water nuclear reactors. The fuel manufacturing operation principally involves converting UF 6 to UO 2 powder, pressing the UO 2 powder into pellets, sintering and grinding the pellets, loading the pellets into Zircaloy tubes, and then assembling the loaded tubes into fuel bundles. A variety of radiological and nonradiological gaseous, liquid, and solid wastes are generated. After treatment, some of the wastes are released to the environment. In addition to the nuclear fuel fabrication operation, there are other operations performed at GE which do not require NRC licensing (e.g., zirconium metal processing, production of fuel bundle and mechanical reactor components, and the manufacture of aircraft engine parts) and are not associated with the proposed action. 28 references, 15 figures, 21 tables

  6. Abdominoplasty and seroma: a prospective randomised study comparing scalpel and handheld electrocautery dissection.

    Science.gov (United States)

    Marsh, Dan J; Fox, Andreas; Grobbelaar, Adriaan O; Chana, Jagdeep S

    2015-02-01

    Seroma formation remains a significant problem in abdominoplasty procedures--the cause of which remains to be elucidated. It has been suggested that one of the causative factors for seroma formation is the use of handheld electrocautery as opposed to scalpel for abdominal flap dissection. Prospective trial in 102 consecutive abdominoplasty patients randomised to have abdominal flap dissection with either handheld electrocautery device on 'coagulation setting' or sharp dissection with scalpel and monopolar electrocautery forceps for haemostasis. In all other aspects the surgical technique was identical between the two groups. All drains were removed at 48 h, irrespective of drain volume. Primary outcome measure is postoperative seroma formation on clinical examination, secondary outcome measures are drain volume, weight of tissue removed, effect of liposuction and patient BMI. Both study groups were similar in demographics with no significant difference in weight of tissue excised, BMI, drain output or post operative complictions. There was no significant difference in seroma formation rates between the handheld electrocautery group (17.2%) and the sharp dissection group (20.1%). Overall, the seroma rate was 18.6%. Liposuction to the flanks at the time of abdominoplasty was found to significantly increase the incidence of seroma, compared to patients having abdominoplasty alone. Use of handheld electrocautery rather than scalpel for tissue dissection does not lead to increased seroma formation in abdominoplasty patients. Concomitant liposuction at the time of abdominoplasty increases the risk of seroma formation compared to patients having abdominoplasty alone. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. A hand-held beta imaging probe for FDG.

    Science.gov (United States)

    Singh, Bipin; Stack, Brendan C; Thacker, Samta; Gaysinskiy, Valeriy; Bartel, Twyla; Lowe, Val; Cool, Steven; Entine, Gerald; Nagarkar, Vivek

    2013-04-01

    Advances in radiopharmaceuticals and clinical understanding have escalated the use of intraoperative gamma probes in surgery. However, most probes on the market are non-imaging gamma probes that suffer from the lack of ancillary information of the surveyed tissue area. We have developed a novel, hand-held digital Imaging Beta Probe™ (IBP™) to be used in surgery in conjunction with beta-emitting radiopharmaceuticals such as (18)FDG, (131)I and (32)P for real-time imaging of a surveyed area with higher spatial resolution and sensitivity and greater convenience than existing instruments. We describe the design and validation of a hand-held beta probe intended to be used as a visual mapping device to locate and confirm excision of (18)FDG-avid primary tumors and metastases in an animal model. We have demonstrated a device which can generate beta images from (18)FDG avid lesions in an animal model. It is feasible to image beta irradiation in animal models of cancer given (18)FDG. This technology may be applied to clinical mapping of tumors and/or their metastases in the operating room. Visual image depiction of malignancy may aid the surgeon in localization and excision of lesions of interest.

  8. Video Browsing on Handheld Devices

    Science.gov (United States)

    Hürst, Wolfgang

    Recent improvements in processing power, storage space, and video codec development enable users now to playback video on their handheld devices in a reasonable quality. However, given the form factor restrictions of such a mobile device, screen size still remains a natural limit and - as the term "handheld" implies - always will be a critical resource. This is not only true for video but any data that is processed on such devices. For this reason, developers have come up with new and innovative ways to deal with large documents in such limited scenarios. For example, if you look at the iPhone, innovative techniques such as flicking have been introduced to skim large lists of text (e.g. hundreds of entries in your music collection). Automatically adapting the zoom level to, for example, the width of table cells when double tapping on the screen enables reasonable browsing of web pages that have originally been designed for large, desktop PC sized screens. A multi touch interface allows you to easily zoom in and out of large text documents and images using two fingers. In the next section, we will illustrate that advanced techniques to browse large video files have been developed in the past years, as well. However, if you look at state-of-the-art video players on mobile devices, normally just simple, VCR like controls are supported (at least at the time of this writing) that only allow users to just start, stop, and pause video playback. If supported at all, browsing and navigation functionality is often restricted to simple skipping of chapters via two single buttons for backward and forward navigation and a small and thus not very sensitive timeline slider.

  9. Web-Based Spatial Training Using Handheld Touch Screen Devices

    Science.gov (United States)

    Martin-Dorta, Norena; Saorin, Jose Luis; Contero, Manuel

    2011-01-01

    This paper attempts to harness the opportunities for mobility and the new user interfaces that handheld touch screen devices offer, in a non-formal learning context, with a view to developing spatial ability. This research has addressed two objectives: first, analyzing the effects that training can have on spatial visualisation using the…

  10. Multimodal ophthalmic imaging using handheld spectrally encoded coherence tomography and reflectometry (SECTR)

    Science.gov (United States)

    Leeburg, Kelsey C.; El-Haddad, Mohamed T.; Malone, Joseph D.; Terrones, Benjamin D.; Tao, Yuankai K.

    2018-02-01

    Scanning laser ophthalmoscopy (SLO) provides high-speed, noninvasive en face imaging of the retinal fundus. Optical coherence tomography (OCT) is the current "gold-standard" for ophthalmic diagnostic imaging and enables depth-resolved visualization of ophthalmic structures and image-based surrogate biomarkers of disease. We present a compact optical and mechanical design for handheld spectrally encoded coherence tomography and reflectometry (SECTR) for multimodality en face spectrally encoded reflectometry (SER) and cross-sectional OCT imaging. We custom-designed a double-pass telecentric scan lens, which halves the size of 4-f optical relays and allowed us to reduce the footprint of our SECTR scan-head by a factor of >2.7x (volume) over our previous design. The double-pass scan lens was optimized for diffraction-limited performance over a +/-10° scan field. SECTR optics and optomechanics were combined in a compact rapid-prototyped enclosure with dimensions 87 x 141.8 x 137 mm (w x h x d). SECTR was implemented using a custom-built 400 kHz 1050 nm swept-source. OCT and SER were simultaneously digitized on dual input channels of a 4 GS/s digitizer at 1.4 GS/s per channel. In vivo human en face SER and cross-sectional OCT images were acquired at 350 fps. OCT volumes of 1000 B-scans were acquired in 2.86 s. We believe clinical translation of our compact handheld design will benefit point-of-care ophthalmic diagnostics in patients who are unable to be imaged on conventional slit-lamp based systems, such as infants and the bedridden. When combined with multi-volumetric registration methods, handheld SECTR will have advantages in motion-artifact free imaging over existing handheld technologies.

  11. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Oh, Mirae; Lee, Hoonsoo; Cho, Hyunjeong; Moon, Sang-Ho; Kim, Eun-Kyung; Kim, Moon S.

    2016-05-01

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by highlighting contaminated food and food contact surfaces on a display monitor. It can be used under ambient lighting conditions in food processing plants. Critical components of the imaging device includes four 405-nm 10-W LEDs for fluorescence excitation, a charge-coupled device (CCD) camera, optical filter (670 nm used for this study), and Wi-Fi transmitter for broadcasting real-time video/images to monitoring devices such as smartphone and tablet. This study aimed to investigate the effectiveness of HFID in enhancing visual detection of fecal contamination on red meat, fat, and bone surfaces of beef under varying ambient luminous intensities (0, 10, 30, 50 and 70 foot-candles). Overall, diluted feces on fat, red meat and bone areas of beef surfaces were detectable in the 670-nm single-band fluorescence images when using the HFID under 0 to 50 foot-candle ambient lighting.

  12. Holdup-related issues in safeguarding of nuclear materials

    International Nuclear Information System (INIS)

    Pillay, K.K.S.

    1988-03-01

    Residual inventories of special nuclear materials (SNM) remaining in processing facilities (holdup) are recognized as an insidious problem for both safety and safeguards. This paper identifies some of the issues that are of concern to the safeguards community at-large that are related to holdup of SNM in large-scale process equipment. These issues range from basic technologies of SNM production to changing regulatory requirements to meet the needs of safeguarding nuclear materials. Although there are no magic formulas to resolve these issues, there are several initiatives that could be taken in areas of facility design, plant operation, personnel training, SNM monitoring, and regulatory guidelines to minimize the problems of holdup and thereby improve both safety and safeguards at nuclear material processing plants. 8 refs

  13. Jump Training in Youth Soccer Players: Effects of Haltere Type Handheld Loading.

    Science.gov (United States)

    Rosas, F; Ramirez-Campillo, R; Diaz, D; Abad-Colil, F; Martinez-Salazar, C; Caniuqueo, A; Cañas-Jamet, R; Loturco, I; Nakamura, F Y; McKenzie, C; Gonzalez-Rivera, J; Sanchez-Sanchez, J; Izquierdo, M

    2016-12-01

    The aim of this study was to compare the effects of a jump training program, with or without haltere type handheld loading, on maximal intensity exercise performance. Youth soccer players (12.1±2.2 y) were assigned to either a jump training group (JG, n=21), a jump training group plus haltere type handheld loading (LJG, n=21), or a control group following only soccer training (CG, n=21). Athletes were evaluated for maximal-intensity performance measures before and after 6 weeks of training, during an in-season training period. The CG achieved a significant change in maximal kicking velocity only (ES=0.11-0.20). Both jump training groups improved in right leg (ES=0.28-0.45) and left leg horizontal countermovement jump with arms (ES=0.32-0.47), horizontal countermovement jump with arms (ES=0.28-0.37), vertical countermovement jump with arms (ES=0.26), 20-cm drop jump reactive strength index (ES=0.20-0.37), and maximal kicking velocity (ES=0.27-0.34). Nevertheless, compared to the CG, only the LJG exhibited greater improvements in all performance tests. Therefore, haltere type handheld loading further enhances performance adaptations during jump training in youth soccer players. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Towards Vision-Based Control of a Handheld Micromanipulator for Retinal Cannulation in an Eyeball Phantom

    Science.gov (United States)

    Becker, Brian C.; Yang, Sungwook; MacLachlan, Robert A.; Riviere, Cameron N.

    2012-01-01

    Injecting clot-busting drugs such as t-PA into tiny vessels thinner than a human hair in the eye is a challenging procedure, especially since the vessels lie directly on top of the delicate and easily damaged retina. Various robotic aids have been proposed with the goal of increasing safety by removing tremor and increasing precision with motion scaling. We have developed a fully handheld micromanipulator, Micron, that has demonstrated reduced tremor when cannulating porcine retinal veins in an “open sky” scenario. In this paper, we present work towards handheld robotic cannulation with the goal of vision-based virtual fixtures guiding the tip of the cannula to the vessel. Using a realistic eyeball phantom, we address sclerotomy constraints, eye movement, and non-planar retina. Preliminary results indicate a handheld micromanipulator aided by visual control is a promising solution to retinal vessel occlusion. PMID:24649479

  15. Real-time inventory system for special nuclear material

    Energy Technology Data Exchange (ETDEWEB)

    Kuckertz, T.H.; Ethridge, C.D.; Nicholson, N.

    1979-01-01

    This paper describes a special purpose peripheral device for a minicomputer that can monitor SNM in vault storage in real time and give timely indication of any tampering with the material. This device, called a shelf monitor, is designed around a single-chip microcomputer, and can be manufactured in quantity for about $100. A typical system of shelf monitors controlled by a minicomputer is described. The minicomputer is used to acquire data associated with the weight and gamma activity of the sample of SNM under observation. Significant deviations in the weight and gamma activity are cause for a tampering alarm.

  16. Real-time inventory system for special nuclear material

    International Nuclear Information System (INIS)

    Kuckertz, T.H.; Ethridge, C.D.; Nicholson, N.

    1979-01-01

    This paper describes a special purpose peripheral device for a minicomputer that can monitor SNM in vault storage in real time and give timely indication of any tampering with the material. This device, called a shelf monitor, is designed around a single-chip microcomputer, and can be manufactured in quantity for about $100. A typical system of shelf monitors controlled by a minicomputer is described. The minicomputer is used to acquire data associated with the weight and gamma activity of the sample of SNM under observation. Significant deviations in the weight and gamma activity are cause for a tampering alarm

  17. Enhancing the performance of a tensioned metastable fluid detector based active interrogation system for the detection of SNM in interrogation source in moderated/reflected geometries

    Science.gov (United States)

    Grimes, T. F.; Hagen, A. R.; Archambault, B. C.; Taleyarkhan, R. P.

    2018-03-01

    This paper describes the development of a SNM detection system for interrogating 1m3 cargos via the combination of a D-D neutron interrogation source (with and without reflectors) and tensioned metastable fluid detectors (TMFDs). TMFDs have been previously shown (Taleyarkhan et al., 2008; Grimes et al., 2015; Grimes and Taleyarkhan, 2016; Archambault et al., 2017; Hagen et al., 2016) to be capable of using Threshold Energy Neutron Analysis (TENA) techniques to reject the ∼2.45 MeV D-D interrogating neutrons while still remaining sensitive to >2.45 MeV neutrons resulting from fission in the target (HEU) material. In order to enhance the performance, a paraffin reflector was included around the accelerator head. This reflector was used to direct neutrons into the package to increase the fission signal, lower the energy of the interrogating neutrons to increase the fission cross-section with HEU, and, also to direct interrogating neutrons away from the detectors in order to enhance the required discrimination between interrogating and fission neutrons. Experiments performed with a 239 Pu-Be neutron source and MnO2 indicated that impressive performance gains could be made by placing a parabolic paraffin moderator between the interrogation source and an air-filled cargo container with HEU placed at the center. However, experiments with other cargo fillers (as specified in the well-known ANSI N42.41-2007 report), and with HEU placed in locations other than the center of the package indicated that other reflector geometries might be superior due to over-"focusing" and the increased solid angle effects due to the accommodation of the moderator geometry. The best performance for the worst case of source location and box fill was obtained by placing the reflector only behind the D-D neutron source rather than in front of it. Finally, it was shown that there could be significant gains in the ability to detect concealed SNM by operating the system in multiple geometric

  18. MEMS-based handheld fourier domain Doppler optical coherence tomography for intraoperative microvascular anastomosis imaging.

    Directory of Open Access Journals (Sweden)

    Yong Huang

    Full Text Available To demonstrate the feasibility of a miniature handheld optical coherence tomography (OCT imager for real time intraoperative vascular patency evaluation in the setting of super-microsurgical vessel anastomosis.A novel handheld imager Fourier domain Doppler optical coherence tomography based on a 1.3-µm central wavelength swept source for extravascular imaging was developed. The imager was minimized through the adoption of a 2.4-mm diameter microelectromechanical systems (MEMS scanning mirror, additionally a 12.7-mm diameter lens system was designed and combined with the MEMS mirror to achieve a small form factor that optimize functionality as a handheld extravascular OCT imager. To evaluate in-vivo applicability, super-microsurgical vessel anastomosis was performed in a mouse femoral vessel cut and repair model employing conventional interrupted suture technique as well as a novel non-suture cuff technique. Vascular anastomosis patency after clinically successful repair was evaluated using the novel handheld OCT imager.With an adjustable lateral image field of view up to 1.5 mm by 1.5 mm, high-resolution simultaneous structural and flow imaging of the blood vessels were successfully acquired for BALB/C mouse after orthotopic hind limb transplantation using a non-suture cuff technique and BALB/C mouse after femoral artery anastomosis using a suture technique. We experimentally quantify the axial and lateral resolution of the OCT to be 12.6 µm in air and 17.5 µm respectively. The OCT has a sensitivity of 84 dB and sensitivity roll-off of 5.7 dB/mm over an imaging range of 5 mm. Imaging with a frame rate of 36 Hz for an image size of 1000(lateral×512(axial pixels using a 50,000 A-lines per second swept source was achieved. Quantitative vessel lumen patency, lumen narrowing and thrombosis analysis were performed based on acquired structure and Doppler images.A miniature handheld OCT imager that can be used for intraoperative evaluation of

  19. Ultra-compact swept-source optical coherence tomography handheld probe with motorized focus adjustment (Conference Presentation)

    Science.gov (United States)

    LaRocca, Francesco; Nankivil, Derek; Keller, Brenton; Farsiu, Sina; Izatt, Joseph A.

    2017-02-01

    Handheld optical coherence tomography (OCT) systems facilitate imaging of young children, bedridden subjects, and those with less stable fixation. Smaller and lighter OCT probes allow for more efficient imaging and reduced operator fatigue, which is critical for prolonged use in either the operating room or neonatal intensive care unit. In addition to size and weight, the imaging speed, image quality, field of view, resolution, and focus correction capability are critical parameters that determine the clinical utility of a handheld probe. Here, we describe an ultra-compact swept source (SS) OCT handheld probe weighing only 211 g (half the weight of the next lightest handheld SSOCT probe in the literature) with 20.1 µm lateral resolution, 7 µm axial resolution, 102 dB peak sensitivity, a 27° x 23° field of view, and motorized focus adjustment for refraction correction between -10 to +16 D. A 2D microelectromechanical systems (MEMS) scanner, a converging beam-at-scanner telescope configuration, and an optical design employing 6 different custom optics were used to minimize device size and weight while achieving diffraction limited performance throughout the system's field of view. Custom graphics processing unit (GPU)-accelerated software was used to provide real-time display of OCT B-scans and volumes. Retinal images were acquired from adult volunteers to demonstrate imaging performance.

  20. The SNM Scanner: A Non-invasive Protocol for Effective Monitoring of Special Nuclear Material Inventories

    International Nuclear Information System (INIS)

    Lanier, R G; Dauffy, L S; Hodge, A M

    2004-01-01

    We suggest a system of monitoring special nuclear material inventories which uses simple mathematical techniques to compare the gross features of emitted gamma-ray spectra. In this report we develop the techniques necessary to make such spectral comparisons and describe their application. We also apply these ideas and develop inventory confirmation results using a room-temperature CdTe detector in a real nuclear-material inventory environment

  1. Quality-Based Backlight Optimization for Video Playback on Handheld Devices

    Directory of Open Access Journals (Sweden)

    Liang Cheng

    2007-01-01

    Full Text Available For a typical handheld device, the backlight accounts for a significant percentage of the total energy consumption (e.g., around 30% for a Compaq iPAQ 3650. Substantial energy savings can be achieved by dynamically adapting backlight intensity levels on such low-power portable devices. In this paper, we analyze the characteristics of video streaming services and propose a cross-layer optimization scheme called quality adapted backlight scaling (QABS to achieve backlight energy savings for video playback applications on handheld devices. Specifically, we present a fast algorithm to optimize backlight dimming while keeping the degradation in image quality to a minimum so that the overall service quality is close to a specified threshold. Additionally, we propose two effective techniques to prevent frequent backlight switching, which negatively affects user perception of video. Our initial experimental results indicate that the energy used for backlight is significantly reduced, while the desired quality is satisfied. The proposed algorithms can be realized in real time.

  2. A conceptual application for computer-based procedures for handheld devices

    Energy Technology Data Exchange (ETDEWEB)

    Sofie, Lunde-Hanssen Linda [Industrial Psychology, Institute for Energy Technology, Halden (Norway)

    2014-08-15

    This paper describes the concepts and proposed design principles for an application for computer-based procedures (CBPs) for field operators in the nuclear domain (so-called handheld procedures). The concept is focused on the field operators' work with procedures and the communication and coordination between field operators and control room operators. The goal is to overcome challenges with shared situation awareness (SA) in a distributed team by providing effective and usable information design. An iterative design method and user-centred design is used for tailoring the concept to the context of field operations. The resulting concept supports the execution of procedures where close collaboration is needed between control room and field operations, e.g. where particular procedure steps are executed from remote control points and others from the control room. The resulting conceptual application for CBPs on handheld devices is developed for mitigating the SA challenges and designing for usability and ease of use.

  3. A conceptual application for computer-based procedures for handheld devices

    International Nuclear Information System (INIS)

    Sofie, Lunde-Hanssen Linda

    2014-01-01

    This paper describes the concepts and proposed design principles for an application for computer-based procedures (CBPs) for field operators in the nuclear domain (so-called handheld procedures). The concept is focused on the field operators' work with procedures and the communication and coordination between field operators and control room operators. The goal is to overcome challenges with shared situation awareness (SA) in a distributed team by providing effective and usable information design. An iterative design method and user-centred design is used for tailoring the concept to the context of field operations. The resulting concept supports the execution of procedures where close collaboration is needed between control room and field operations, e.g. where particular procedure steps are executed from remote control points and others from the control room. The resulting conceptual application for CBPs on handheld devices is developed for mitigating the SA challenges and designing for usability and ease of use

  4. Handheld Nonlinear Detection of Delamination and Intrusion Faults in Composites, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase I of the SBIR program, LEEOAT Company will develop a hand-held high-resolution ultrasonic nonlinear imager for non-destructive inspection (NDI) of...

  5. Combining heterogenous features for 3D hand-held object recognition

    Science.gov (United States)

    Lv, Xiong; Wang, Shuang; Li, Xiangyang; Jiang, Shuqiang

    2014-10-01

    Object recognition has wide applications in the area of human-machine interaction and multimedia retrieval. However, due to the problem of visual polysemous and concept polymorphism, it is still a great challenge to obtain reliable recognition result for the 2D images. Recently, with the emergence and easy availability of RGB-D equipment such as Kinect, this challenge could be relieved because the depth channel could bring more information. A very special and important case of object recognition is hand-held object recognition, as hand is a straight and natural way for both human-human interaction and human-machine interaction. In this paper, we study the problem of 3D object recognition by combining heterogenous features with different modalities and extraction techniques. For hand-craft feature, although it reserves the low-level information such as shape and color, it has shown weakness in representing hiconvolutionalgh-level semantic information compared with the automatic learned feature, especially deep feature. Deep feature has shown its great advantages in large scale dataset recognition but is not always robust to rotation or scale variance compared with hand-craft feature. In this paper, we propose a method to combine hand-craft point cloud features and deep learned features in RGB and depth channle. First, hand-held object segmentation is implemented by using depth cues and human skeleton information. Second, we combine the extracted hetegerogenous 3D features in different stages using linear concatenation and multiple kernel learning (MKL). Then a training model is used to recognize 3D handheld objects. Experimental results validate the effectiveness and gerneralization ability of the proposed method.

  6. Pre-test habituation improves the reliability of a handheld test of mechanical nociceptive threshold in dairy cows

    DEFF Research Database (Denmark)

    Raundal, P. M.; Andersen, P. H.; Toft, Nils

    2015-01-01

    Mechanical nociceptive threshold (MNT) testing has been used to investigate aspects of painful states in bovine claws. We investigated a handheld tool, where the applied stimulation force was monitored continuously relative to a pre-encoded based target force. The effect on MNT of two pre-testing...... habituation procedures was performed in two different experiments comprising a total of 88 sound Holsteins dairy cows kept either inside or outside their home environment. MNT testing was performed using five consecutive mechanical nociceptive stimulations per cow per test at a fixed pre-encoded target rate...... of 2.1 N/s. The habituation procedure performed in dairy cows kept in their home environment led to lowered intra-individual coefficient of variation of MNT (P test...

  7. 78 FR 27441 - NIJ Evaluation of Hand-Held Cell Phone Detector Devices

    Science.gov (United States)

    2013-05-10

    ...The National Institute of Justice (NIJ) is soliciting interest in supplying hand-held cell phone detector devices for participation in an evaluation by the NIJ Corrections Technology Center of Excellence (CXCoE).

  8. Optical links in handheld multimedia devices

    Science.gov (United States)

    van Geffen, S.; Duis, J.; Miller, R.

    2008-04-01

    Ever emerging applications in handheld multimedia devices such as mobile phones, laptop computers, portable video games and digital cameras requiring increased screen resolutions are driving higher aggregate bitrates between host processor and display(s) enabling services such as mobile video conferencing, video on demand and TV broadcasting. Larger displays and smaller phones require complex mechanical 3D hinge configurations striving to combine maximum functionality with compact building volumes. Conventional galvanic interconnections such as Micro-Coax and FPC carrying parallel digital data between host processor and display module may produce Electromagnetic Interference (EMI) and bandwidth limitations caused by small cable size and tight cable bends. To reduce the number of signals through a hinge, the mobile phone industry, organized in the MIPI (Mobile Industry Processor Interface) alliance, is currently defining an electrical interface transmitting serialized digital data at speeds >1Gbps. This interface allows for electrical or optical interconnects. Above 1Gbps optical links may offer a cost effective alternative because of their flexibility, increased bandwidth and immunity to EMI. This paper describes the development of optical links for handheld communication devices. A cable assembly based on a special Plastic Optical Fiber (POF) selected for its mechanical durability is terminated with a small form factor molded lens assembly which interfaces between an 850nm VCSEL transmitter and a receiving device on the printed circuit board of the display module. A statistical approach based on a Lean Design For Six Sigma (LDFSS) roadmap for new product development tries to find an optimum link definition which will be robust and low cost meeting the power consumption requirements appropriate for battery operated systems.

  9. Advanced accounting techniques in automated fuel fabrication facilities

    International Nuclear Information System (INIS)

    Carlson, R.L.; DeMerschman, A.W.; Engel, D.W.

    1977-01-01

    The accountability system being designed for automated fuel fabrication facilities will provide real-time information on all Special Nuclear Material (SNM) located in the facility. It will utilize a distributed network of microprocessors and minicomputers to monitor material movement and obtain nuclear materials measurements directly from remote, in-line Nondestructive Assay instrumentation. As SNM crosses an accounting boundary, the accountability computer will update the master files and generate audit trail records. Mass balance accounting techniques will be used around each unit process step, while item control will be used to account for encapsulated material, and SNM in transit

  10. Development and performance of a hand-held CZT detector for in-situ measurements at the emergency response

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Young Yong; Chung, Kun Ho; Kim, Chang Jong; Lee, Wan No; Choi, Geun Sik; Kang, Mun Ja [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Yoon, Jin [SI Detection Co. Ltd, Daejeon (Korea, Republic of)

    2016-06-15

    A hand-held detector for an emergency response was developed for nuclide identification and to estimate the information of the ambient dose rate in the scene of an accident as well as the radioactivity of the contaminants. To achieve this, the most suitable sensor was first selected as a cadmium zinc telluride (CZT) semiconductor and the signal processing unit from a sensor and the signal discrimination and storage unit were successfully manufactured on a printed circuit board. The performance of the developed signal processing unit was then evaluated to have an energy resolution of about 14 keV at 662 keV. The system control unit was also designed to operate the CZT detector, monitor the detector, battery, and interface status, and check and transmit the measured results of the ambient dose rate and radioactivity. In addition, a collimator, which can control the inner radius, and the airborne dust sampler, which consists of an air filter and charcoal filter, were developed and mounted to the developed CZT detector for the quick and efficient response of a nuclear accident. The hand-held CZT detector was developed to make the in-situ gamma-ray spectrometry and its performance was checked to have a good energy resolution. In addition, the collimator and the airborne dust sampler were developed and mounted to the developed CZT detector for a quick and efficient response to a nuclear accident.

  11. Audiovisual Presentations on a Handheld PC are Preferred As an Educational Tool by NICU Parents.

    Science.gov (United States)

    Alur, P; Cirelli, J; Goodstein, M; Bell, T; Liss, J

    2010-01-01

    Health literacy is critical for understanding complex medical problems and necessary for the well being of the patient. Printed educational materials (PM) have limitations in explaining the dynamics of a disease process. Multimedia formats may be useful for enhancing the educational process. To evaluate whether a printed format or animation with commentary on a handheld personal computer (PC) is preferred as an educational tool by parents of a baby in the NICU. PARENTS EVALUATED TWO FORMATS: A 1-page illustrated document from the American Heart Association explaining patent ductus arteriosus (PDA) and animation with commentary on a handheld PC that explained the physiology of PDA in 1 minute. The reading grade level of the PM was 8.6 versus 18.6 for the audio portion of the animated presentation. Parents viewed each format and completed a four-item questionnaire. Parents rated both formats and indicated their preference as printed, animation, or both. Forty-six parents participated in the survey. Parents preferred animation over PM (50% vs. 17.4%. p = 0.02); 39.1% expressed that the animation was excellent; whereas 4.3% expressed that the PM was excellent (p0.05). Parents preferred animation on a small screen handheld PC despite a much higher language level. Because handheld PCs are portable and inexpensive, they can be used effectively at the bedside with low-cost animation to enhance understanding of complex disease conditions.

  12. Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City

    Directory of Open Access Journals (Sweden)

    Sumanth Mallikarjuna Majgi

    2018-01-01

    Full Text Available Background: Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. Methods: The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. Results: The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads (Χ2 = 25.79, P < 0.0001. More than 50% of the handheld phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. Conclusions: The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads.

  13. Performance Analysis of Nomadic Mobile Services on Multi-homed Handheld Devices

    NARCIS (Netherlands)

    Pawar, P.; van Beijnum, Bernhard J.F.; van Sinderen, Marten J.; Aggarwal, Akshai; De Clercq, Frederic

    2007-01-01

    Compared to their predecessors, the current generation handheld mobile devices possess higher processing power, increased memory and new multi-homing capabilities. These features combined with the widespread acceptance and use of these devices result in a situation where mobile devices are no longer

  14. How to use hand-held computers to evaluate wood drying.

    Science.gov (United States)

    Howard N. Rosen; Darrell S. Martin

    1985-01-01

    Techniques have been developed to evaluate end generate wood drying curves with hand-held computers (3-5K memory). Predictions of time to dry to a specific moisture content, drying rates, and other characteristics of wood drying curves can be made. The paper describes the development of programs and illustrates their use.

  15. A prototype wearable tritium monitor

    International Nuclear Information System (INIS)

    Surette, R. A.; Dubeau, J.

    2008-01-01

    Sudden unexpected changes in tritium-in-air concentrations in workplace air can result in significant unplanned exposures. Although fixed area monitors are used to monitor areas where there is a potential for elevated tritium in air concentrations, they do not monitor personnel air space and may require some time for acute tritium releases to be detected. There is a need for a small instrument that will quickly alert staff of changing tritium hazards. A moderately sensitive tritium instrument that workers could wear would bring attention to any rise in tritium levels that were above predetermined limits and help in assessing the potential hazard therefore minimizing absorbed dose. Hand-held instruments currently available can be used but require the assistance of a fellow worker or restrict the user to using only one hand to perform some duties. (authors)

  16. Handheld Devices with Wide-Area Wireless Connectivity: Applications in Astronomy Educational Technology and Remote Computational Control

    Science.gov (United States)

    Budiardja, R. D.; Lingerfelt, E. J.; Guidry, M. W.

    2003-05-01

    Wireless technology implemented with handheld devices has attractive features because of the potential to access large amounts of data and the prospect of on-the-fly computational analysis from a device that can be carried in a shirt pocket. We shall describe applications of such technology to the general paradigm of making digital wireless connections from the field to upload information and queries to network servers, executing (potentially complex) programs and controlling data analysis and/or database operations on fast network computers, and returning real-time information from this analysis to the handheld device in the field. As illustration, we shall describe several client/server programs that we have written for applications in teaching introductory astronomy. For example, one program allows static and dynamic properties of astronomical objects to be accessed in a remote observation laboratory setting using a digital cell phone or PDA. Another implements interactive quizzing over a cell phone or PDA using a 700-question introductory astronomy quiz database, thus permitting students to study for astronomy quizzes in any environment in which they have a few free minutes and a digital cell phone or wireless PDA. Another allows one to control and monitor a computation done on a Beowulf cluster by changing the parameters of the computation remotely and retrieving the result when the computation is done. The presentation will include hands-on demonstrations with real devices. *Managed by UT-Battelle, LLC, for the U.S. Department of Energy under contract DE-AC05-00OR22725.

  17. ENGAGING SCIENCE STUDENTS WITH HANDHELD TECHNOLOGY AND APPLICATIONS BY RE-VISITING THE THAYER METHOD OF TEACHING AND LEARNING

    Directory of Open Access Journals (Sweden)

    Julia Paredes

    2011-12-01

    Full Text Available Organic chemistry instructors integrate handheld technology and applications into course lecture and lab to engage students with tools and techniques students use in the modern world. This technology and applications enable instructors to re-visit the Thayer Method of teaching and learning to create an updated method that works with 21st century students. The Thayer Method is based on the premise that students are willing and capable of making substantial preparation before coming to class and lab in order to maximize efficiency of student-instructor contact time. During this student preparation phase, we engage students with handheld technology and content applications including smart phone viewable course administrative materials; “flashcards” containing basic organic chemistry nomenclature, molecular structures, and chemical reactions; mini-lectures prepared using the Smart Board Airliner Interactive Tablet for upcoming class periods and laboratory technique videos demonstrating tasks they will perform as part of laboratory experimentation. Coupled with a student friendly course text, these handheld applications enable substantial student preparation before class and lab. The method, in conjunction with handheld technology and applications, has been used with positive results in our organic chemistry courses.

  18. Environmental radiation monitoring technology: Capabilities and needs

    International Nuclear Information System (INIS)

    Hofstetter, K.J.

    1994-01-01

    Radiation monitoring in the Savannah River Site (SRS) environment is conducted by a combination of automated, remote sampling and/or analysis systems, and manual sampling operations. This program provides early detection of radionuclide releases, minimizes the consequences, and assesses the impact on the public. Instrumentation installed at the release points monitor the atmospheric and aqueous releases from SRS operations. Ground water and air monitoring stations are strategically located throughout the site for radionuclide migration studies. The environmental radiological monitoring program at SRS includes: fixed monitoring stations for atmospheric radionuclide concentrations, aqueous monitors for surface water measurements, mobile laboratory operations for real-time, in-field measurements, aerial scanning for wide area contamination surveillance, and hand-held instruments for radionuclide-specific measurements. Rigorous environmentnal sampling surveillance coupled with laboratory analyses provide confirmatory results for all in-field measurements. Gaps in the technologies and development projects at SRS to fill these deficiencies are discussed in the context of customer needs and regulatory requirements

  19. The Weak Link HP-41C hand-held calculator program

    Science.gov (United States)

    Ross A. Phillips; Penn A. Peters; Gary D. Falk

    1982-01-01

    The Weak Link hand-held calculator program (HP-41C) quickly analyzes a system for logging production and costs. The production equations model conventional chain saw, skidder, loader, and tandemaxle truck operations in eastern mountain areas. Production of each function of the logging system may be determined so that the system may be balanced for minimum cost. The...

  20. Standardization from a benchtop to a handheld NIR spectrometer using mathematically mixed NIR spectra to determine fuel quality parameters

    DEFF Research Database (Denmark)

    da Silva, Neirivaldo Cavalcante; Cavalcanti, Claudia Jessica; Honorato, Fernanda Araujo

    2017-01-01

    spectral responses of fuel samples (gasoline and biodiesel blends) from a high-resolution benchtop Frontier FT-NIR (PerkinElmer) spectrometer and a handheld MicroNIR™1700 (JDSU). These virtual standards can be created by mathematically mixing spectra from the pure solvents present in gasoline or diesel...... to the handheld MicroNIR using virtual standards as transfer samples...

  1. Development of dual sensor hand-held detector

    Science.gov (United States)

    Sezgin, Mehmet

    2010-04-01

    In this paper hand-held dual sensor detector development requirements are considered dedicated to buried object detection. Design characteristics of such a system are categorized and listed. Hardware and software structures, ergonomics, user interface, environmental and EMC/EMI tests to be applied and performance test issues are studied. Main properties of the developed system (SEZER) are presented, which contains Metal Detector (MD) and Ground Penetrating Radar (GPR). The realized system has ergonomic structure and can detect both metallic and non-metallic buried objects. Moreover classification of target is possible if it was defined to the signal processing software in learning phase.

  2. Reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH Sensor), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of rHEALTH sensor is a universal handheld sensor that can provide rapid, low-cost complete blood count (CBC) with differential, electrolyte analysis, and...

  3. Reusable Handheld Electrolytes and Lab Technology for Humans (rHEALTH Sensor), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of the rHEALTH sensor is to provide rapid, low-cost, handheld complete blood count (CBC), cell differential counts, electrolyte measurements, and other lab...

  4. The Study on the Innovation System of Strategic and Emerging Industries Based on The SNM Theory%基于战略生态位管理理论的战略性新兴产业创新系统研究

    Institute of Scientific and Technical Information of China (English)

    李华军; 张光宇; 刘贻新

    2012-01-01

    回顾了战略生态位管理(SNM)理论,丰富和完善了SNM理论体系,运用SNM理论归纳了战略性新兴产业创新系统的理论架构.在分析创新系统要素与作用机理的基础上,构建了战略性新兴产业创新系统及相关模型.提出应在创新系统中通过战略生态位空间的构建、优化和突变,使得技术生态位成功过渡到市场生态位,突破“技术制度锁定”效应,实现产业变革.%Based on the review about the emerging theory of strategic niche management (SNM), this paper enriches and improves its theoretical framework, then use SNM theory to summarize the innovation system's theoretical framework of strategic and emerging industries. By analyzing the innovation system's elements and mechanism, constructs the strategic and emerging industries' innovation system and related models. It Puts forward through the construction, optimization and mutation of strategic niche space in the innovation system, to make a successful transition from technology niche to market niche, break through the "technology-system lock in"effect, and transforming the industry, these provide new perspective and path to foster and develop strategic and emerging industries.

  5. PROSPECTIVE EVALUATION OF VISUAL ACUITY AGREEMENT BETWEEN STANDARD EARLY TREATMENT DIABETIC RETINOPATHY STUDY CHART AND A HANDHELD EQUIVALENT IN EYES WITH RETINAL PATHOLOGY.

    Science.gov (United States)

    Rahimy, Ehsan; Reddy, Sahitya; DeCroos, Francis Char; Khan, M Ali; Boyer, David S; Gupta, Omesh P; Regillo, Carl D; Haller, Julia A

    2015-08-01

    To evaluate the visual acuity agreement between a standard back-illuminated Early Treatment Diabetic Retinopathy Study (ETDRS) chart and a handheld internally illuminated ETDRS chart. Two-center prospective study. Seventy patients (134 eyes) with retinal pathology were enrolled between October 2012 and August 2013. Visual acuity was measured using both the ETDRS chart and the handheld device by masked independent examiners after best protocol refraction. Examination was performed in the same room under identical illumination and testing conditions. The mean number of letters seen was 63.0 (standard deviation: 19.8 letters) and 61.2 letters (standard deviation: 19.1 letters) for the ETDRS chart and handheld device, respectively. Mean difference per eye between the ETDRS and handheld device was 1.8 letters. A correlation coefficient (r) of 0.95 demonstrated a positive linear correlation between ETDRS chart and handheld device measured acuities. Intraclass correlation coefficient was performed to assess the reproducibility of the measurements made by different observers measuring the same quantity and was calculated to be 0.95 (95% confidence interval: 0.93-0.96). Agreement was independent of retinal disease. The strong correlation between measured visual acuity using the ETDRS and handheld equivalent suggests that they may be used interchangeably, with accurate measurements. Potential benefits of this device include convenience and portability, as well as the ability to assess ETDRS visual acuity without a dedicated testing lane.

  6. Gen-2 Hand-Held Optical Imager towards Cancer Imaging: Reflectance and Transillumination Phantom Studies

    Directory of Open Access Journals (Sweden)

    Anuradha Godavarty

    2012-02-01

    Full Text Available Hand-held near-infrared (NIR optical imagers are developed by various researchers towards non-invasive clinical breast imaging. Unlike these existing imagers that can perform only reflectance imaging, a generation-2 (Gen-2 hand-held optical imager has been recently developed to perform both reflectance and transillumination imaging. The unique forked design of the hand-held probe head(s allows for reflectance imaging (as in ultrasound and transillumination or compressed imaging (as in X-ray mammography. Phantom studies were performed to demonstrate two-dimensional (2D target detection via reflectance and transillumination imaging at various target depths (1–5 cm deep and using simultaneous multiple point illumination approach. It was observed that 0.45 cc targets were detected up to 5 cm deep during transillumination, but limited to 2.5 cm deep during reflectance imaging. Additionally, implementing appropriate data post-processing techniques along with a polynomial fitting approach, to plot 2D surface contours of the detected signal, yields distinct target detectability and localization. The ability of the gen-2 imager to perform both reflectance and transillumination imaging allows its direct comparison to ultrasound and X-ray mammography results, respectively, in future clinical breast imaging studies.

  7. The reliability and validity of hand-held refractometry water content measures of hydrogel lenses.

    Science.gov (United States)

    Nichols, Jason J; Mitchell, G Lynn; Good, Gregory W

    2003-06-01

    To investigate within- and between-examiner reliability and validity of hand-held refractometry water content measures of hydrogel lenses. Nineteen lenses of various nominal water contents were examined by two examiners on two occasions separated by 1 hour. An Atago N2 hand-held refractometer was used for all water content measures. Lenses were presented in a random order to each examiner by a third party, and examiners were masked to any potential lens identifiers. Intraclass correlation coefficients (ICC), 95% limits of agreement, and Wilcoxon signed rank test were used to characterize the within- and between-examiner reliability and validity of lens water content measures. Within-examiner reliability was excellent (ICC, 0.97; 95% limits of agreement, -3.6% to +5.7%), and the inter-visit mean difference of 1.1 +/- 2.4% was not biased (p = 0.08). Between-examiner reliability was also excellent (ICC, 0.98; 95% limits of agreement, -4.1% to +3.9%). The mean difference between examiners was -0.1 +/- 2.1% (p = 0.83). The mean difference between the nominally reported water content and our water content measures was -2.1 +/- 1.7% (p refractometry and is material dependent. Therefore, investigators may need to account for bias when measuring hydrogel lens water content via hand-held refractometry.

  8. Hand-held transendoscopic robotic manipulators: A transurethral laser prostate surgery case study.

    Science.gov (United States)

    Hendrick, Richard J; Mitchell, Christopher R; Herrell, S Duke; Webster, Robert J

    2015-11-01

    Natural orifice endoscopic surgery can enable incisionless approaches, but a major challenge is the lack of small and dexterous instrumentation. Surgical robots have the potential to meet this need yet often disrupt the clinical workflow. Hand-held robots that combine thin manipulators and endoscopes have the potential to address this by integrating seamlessly into the clinical workflow and enhancing dexterity. As a case study illustrating the potential of this approach, we describe a hand-held robotic system that passes two concentric tube manipulators through a 5 mm port in a rigid endoscope for transurethral laser prostate surgery. This system is intended to catalyze the use of a clinically superior, yet rarely attempted, procedure for benign prostatic hyperplasia. This paper describes system design and experiments to evaluate the surgeon's functional workspace and accuracy using the robot. Phantom and cadaver experiments demonstrate successful completion of the target procedure via prostate lobe resection.

  9. Nonproliferation and safeguarding via ionization detection

    International Nuclear Information System (INIS)

    Koster, J.E.; Johnson, J.P.; Steadman, P.

    1995-01-01

    A significant signature of the presence of special nuclear material (SNM) is ionizing radiation. SNM naturally decays with the emission of alpha particles, gamma rays, and neutrons. Detecting and monitoring these emissions is an important capability for international safeguards. A new detection method collects the ions produced by such radiation in ambient air. Alpha particles in particular are specific to heavy nuclei but have very short range. The ions produced by an alpha, however, can be transported tens of meters to an ion detector. These new monitors are rugged, very sensitive, respond in real time, and in most cases are quite portable

  10. Maintaining radiation exposures as low as reasonably achievable (ALARA) for dental personnel operating portable hand-held x-ray equipment.

    Science.gov (United States)

    McGiff, Thomas J; Danforth, Robert A; Herschaft, Edward E

    2012-08-01

    Clinical experience indicates that newly available portable hand-held x-ray units provide advantages compared to traditional fixed properly installed and operated x-ray units in dental radiography. However, concern that hand-held x-ray units produce higher operator doses than fixed x-ray units has caused regulatory agencies to mandate requirements for use of hand-held units that go beyond those recommended by the manufacturer and can discourage the use of this technology. To assess the need for additional requirements, a hand-held x-ray unit and a pair of manikins were used to measure the dose to a simulated operator under two conditions: exposures made according to the manufacturer's recommendations and exposures made according to manufacturer's recommendation except for the removal of the x-ray unit's protective backscatter shield. Dose to the simulated operator was determined using an array of personal dosimeters and a pair of pressurized ion chambers. The results indicate that the dose to an operator of this equipment will be less than 0.6 mSv y⁻¹ if the device is used according to the manufacturer's recommendations. This suggests that doses to properly trained operators of well-designed, hand-held dental x-ray units will be below 1.0 mSv y⁻¹ (2% of the annual occupational dose limit) even if additional no additional operational requirements are established by regulatory agencies. This level of annual dose is similar to those reported as typical dental personnel using fixed x-ray units and appears to satisfy the ALARA principal for this class of occupational exposures.

  11. Monitoring around the secret nuclear facilities of naval ports; Surveillance autour des INBS des ports militaires

    Energy Technology Data Exchange (ETDEWEB)

    Jaskierowicz, D. [Marine Nationale, pharmacien en chef, conseiller scientifique et technique, etat-major de la marine, 83 - Toulon (France); Quere, St. [Marine Nationale, capitaine de corvette, adjoint charge de la prise en compte des installations nucleaires sur l' environnement et le personnel, 83 - Toulon (France)

    2010-06-15

    Based within large industrial cities (Brest, Toulon, Cherbourg) or more rural areas like Crozon (Ile Longue), French navy exploits nuclear facilities where are built, maintained and decommissioned nuclear power submarines and aircraft-carrier. The safety and the security of these installations as well as the non-impact on people and environment are continuously monitored. The DSND, a governmental regulatory body dedicated to the Defense, applies the same regulations enforced by the ASN for civilian nuclear activities. Concerning environmental monitoring, the navy answers to the DSND or the ASN, depending on the type of survey. In every nuclear site, an automatic nuclear monitoring sensor system (2SNM) runs 24/7, with the supervision of specialized personnel in radioprotection. Each year, more than 7000 samples are collected in the ecosystem and thousands of measurements are carried out in four laboratories (LASEM in Cherbourg, Brest and Toulon) - SPRS ILO) of the navy. These results are sent to the DSND and have been integrated since February 2010 to the brand-new public web site of the national monitoring network of radioactivity in the environment (RMN). (author)

  12. Classification and Visualization of Physical and Chemical Properties of Falsified Medicines with Handheld Raman Spectroscopy and X-Ray Computed Tomography.

    Science.gov (United States)

    Kakio, Tomoko; Yoshida, Naoko; Macha, Susan; Moriguchi, Kazunobu; Hiroshima, Takashi; Ikeda, Yukihiro; Tsuboi, Hirohito; Kimura, Kazuko

    2017-09-01

    Analytical methods for the detection of substandard and falsified medical products (SFs) are important for public health and patient safety. Research to understand how the physical and chemical properties of SFs can be most effectively applied to distinguish the SFs from authentic products has not yet been investigated enough. Here, we investigated the usefulness of two analytical methods, handheld Raman spectroscopy (handheld Raman) and X-ray computed tomography (X-ray CT), for detecting SFs among oral solid antihypertensive pharmaceutical products containing candesartan cilexetil as an active pharmaceutical ingredient (API). X-ray CT visualized at least two different types of falsified tablets, one containing many cracks and voids and the other containing aggregates with high electron density, such as from the presence of the heavy elements. Generic products that purported to contain equivalent amounts of API to the authentic products were discriminated from the authentic products by the handheld Raman and the different physical structure on X-ray CT. Approach to investigate both the chemical and physical properties with handheld Raman and X-ray CT, respectively, promise the accurate discrimination of the SFs, even if their visual appearance is similar with authentic products. We present a decision tree for investigating the authenticity of samples purporting to be authentic commercial tablets. Our results indicate that the combination approach of visual observation, handheld Raman and X-ray CT is a powerful strategy for nondestructive discrimination of suspect samples.

  13. Adaptive RF front-ends for hand-held applications

    CERN Document Server

    van Bezooijen, Andre; van Roermund, Arthur

    2010-01-01

    The RF front-end - antenna combination is a vital part of a mobile phone because its performance is very relevant to the link quality between hand-set and cellular network base-stations. The RF front-end performance suffers from changes in operating environment, like hand-effects, that are often unpredictable. ""Adaptive RF Front-Ends for Hand-Held Applications"" presents an analysis on the impact of fluctuating environmental parameters. In order to overcome undesired behavior two different adaptive control methods are treated that make RF frond-ends more resilient: adaptive impedance control,

  14. Handheld Longwave Infrared Camera Based on Highly-Sensitive Quantum Well Infrared Photodetectors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop a compact handheld longwave infrared camera based on quantum well infrared photodetector (QWIP) focal plane array (FPA) technology. Based on...

  15. A data-driven design evaluation tool for handheld device soft keyboards.

    Directory of Open Access Journals (Sweden)

    Matthieu B Trudeau

    Full Text Available Thumb interaction is a primary technique used to operate small handheld devices such as smartphones. Despite the different techniques involved in operating a handheld device compared to a personal computer, the keyboard layouts for both devices are similar. A handheld device keyboard that considers the physical capabilities of the thumb may improve user experience. We developed and applied a design evaluation tool for different geometries of the QWERTY keyboard using a performance evaluation model. The model utilizes previously collected data on thumb motor performance and posture for different tap locations and thumb movement directions. We calculated a performance index (PITOT, 0 is worst and 2 is best for 663 designs consisting in different combinations of three variables: the keyboard's radius of curvature (R (mm, orientation (O (°, and vertical location on the screen (L. The current standard keyboard performed poorly (PITOT = 0.28 compared to other designs considered. Keyboard location (L contributed to the greatest variability in performance out of the three design variables, suggesting that designers should modify this variable first. Performance was greatest for designs in the middle keyboard location. In addition, having a slightly upward curve (R = -20 mm and orientated perpendicular to the thumb's long axis (O = -20° improved performance to PITOT = 1.97. Poorest performances were associated with placement of the keyboard's spacebar in the bottom right corner of the screen (e.g., the worst was for R = 20 mm, O = 40°, L =  Bottom (PITOT = 0.09. While this evaluation tool can be used in the design process as an ergonomic reference to promote user motor performance, other design variables such as visual access and usability still remain unexplored.

  16. Comparative Geometrical Accuracy Investigations of Hand-Held 3d Scanning Systems - AN Update

    Science.gov (United States)

    Kersten, T. P.; Lindstaedt, M.; Starosta, D.

    2018-05-01

    Hand-held 3D scanning systems are increasingly available on the market from several system manufacturers. These systems are deployed for 3D recording of objects with different size in diverse applications, such as industrial reverse engineering, and documentation of museum exhibits etc. Typical measurement distances range from 0.5 m to 4.5 m. Although they are often easy-to-use, the geometric performance of these systems, especially the precision and accuracy, are not well known to many users. First geometrical investigations of a variety of diverse hand-held 3D scanning systems were already carried out by the Photogrammetry & Laser Scanning Lab of the HafenCity University Hamburg (HCU Hamburg) in cooperation with two other universities in 2016. To obtain more information about the accuracy behaviour of the latest generation of hand-held 3D scanning systems, HCU Hamburg conducted further comparative geometrical investigations using structured light systems with speckle pattern (Artec Spider, Mantis Vision PocketScan 3D, Mantis Vision F5-SR, Mantis Vision F5-B, and Mantis Vision F6), and photogrammetric systems (Creaform HandySCAN 700 and Shining FreeScan X7). In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data was acquired by measurements with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  17. A Fresh Look at the Crystal Violet Lab with Handheld Camera Colorimetry

    Science.gov (United States)

    Knutson, Theodore R.; Knutson, Cassandra M.; Mozzetti, Abbie R.; Campos, Antonio R.; Haynes, Christy L.; Penn, R. Lee

    2015-01-01

    Chemical kinetic experiments to determine rate laws are common in high school and college chemistry courses. For reactions involving a color change, rate laws can be determined experimentally using spectrophotometric or colorimetric equipment though this equipment can be cost prohibitive. Previous work demonstrated that inexpensive handheld camera…

  18. Torque Removal Evaluation of Screw in One-Piece and Two-Piece Abutments Tightened with a Handheld screwdriver

    Directory of Open Access Journals (Sweden)

    Jalil Ghanbarzadeh

    2013-12-01

    Full Text Available Introduction: Some clinicians use a handheld screw driver instead of a torque wrench to definitively tighten abutment screws. The aim of this study was to compare the removal torque of one-piece and two-piece abutments tightened with a handheld driver and a torque control ratchet. Methods: 40 ITI implants were placed in acrylic blocks and divided into 4 groups. In groups one and two, 10 ITI one-piece abutments (Solid® and in groups three and four, 10 ITI two-piece abutments (Synocta® were placed on the implants. In groups one and three abutments were tightened by 5 experienced males and 5 experienced females using a handheld driver. In groups two and four abutments were tightened using a torque wrench with torque values of 10, 20 and 35 N.cm. Insertion torque and removal torque values of the abutments were measured with a digital torque meter. Results: The insertion torque values (ITVs of males in both abutments were significantly higher than those of females. ITVs in both Solid® and Synocta® abutments tightened with a handheld screwdriver were similar to the torque of 20 N.cm in the torque wrench. Removal torque values (RTVs of solid® abutments were higher than those of synocta® abutments. Conclusion: The one- piece abutments (solid® showed higher RTVs than the two-piece abutments (synocta®. Hand driver does not produce sufficient preload force for the final tightening of the abutment

  19. Handheld Delivery System for Modified Boron-Type Fire Extinguishment Agent

    Science.gov (United States)

    1993-11-01

    was to develop and test a handheld portable delivery system for use with the modified boron-type fire extinguishing agent for metal fires . B...BACKGROUND A need exists for an extinguishing agent and accompanying delivery system that are effective against complex geometry metal fires . A modified...agent and its delivery system have proven effective against complex geometry metal fires containing up to 200 pounds of magnesium metal. Further

  20. Handheld microwave bomb-detecting imaging system

    Science.gov (United States)

    Gorwara, Ashok; Molchanov, Pavlo

    2017-05-01

    Proposed novel imaging technique will provide all weather high-resolution imaging and recognition capability for RF/Microwave signals with good penetration through highly scattered media: fog, snow, dust, smoke, even foliage, camouflage, walls and ground. Image resolution in proposed imaging system is not limited by diffraction and will be determined by processor and sampling frequency. Proposed imaging system can simultaneously cover wide field of view, detect multiple targets and can be multi-frequency, multi-function. Directional antennas in imaging system can be close positioned and installed in cell phone size handheld device, on small aircraft or distributed around protected border or object. Non-scanning monopulse system allows dramatically decrease in transmitting power and at the same time provides increased imaging range by integrating 2-3 orders more signals than regular scanning imaging systems.

  1. Comparing a recursive digital filter with the moving-average and sequential probability-ratio detection methods for SNM portal monitors

    International Nuclear Information System (INIS)

    Fehlau, P.E.

    1993-01-01

    The author compared a recursive digital filter proposed as a detection method for French special nuclear material monitors with the author's detection methods, which employ a moving-average scaler or a sequential probability-ratio test. Each of these nine test subjects repeatedly carried a test source through a walk-through portal monitor that had the same nuisance-alarm rate with each method. He found that the average detection probability for the test source is also the same for each method. However, the recursive digital filter may have on drawback: its exponentially decreasing response to past radiation intensity prolongs the impact of any interference from radiation sources of radiation-producing machinery. He also examined the influence of each test subject on the monitor's operation by measuring individual attenuation factors for background and source radiation, then ranked the subjects' attenuation factors against their individual probabilities for detecting the test source. The one inconsistent ranking was probably caused by that subject's unusually long stride when passing through the portal

  2. Handheld Versus Wearable Interaction Design for Professionals - A Case Study of Hospital Service Work

    DEFF Research Database (Denmark)

    Stisen, Allan; Blunck, Henrik; Kjærgaard, Mikkel Baun

    2014-01-01

    With the blooming of new available wrist worn devices there are potentials for these to support the work done in many professional domains. One such domain is hospital service work. This paper explores two wearable prototypes with regards to challenges and opportunities to support future hospital...... service work. This explorative study was conducted with 4 experienced hospital orderlies who interacted with an application across two wearable concepts, and one handheld smartphone in five scenarios in a hospital environment. The interaction was video recorded with a chest-mounted video afterwards semi...... structured interviews with each participant was conducted. This study shows that wearable computers can effectively support the maintenance work of the orderlies and has domain specific advantages over the handheld smartphone, e.g., the former support glancing at the task information. Furthermore, we outline...

  3. Selected topics in special nuclear materials safeguard system design

    International Nuclear Information System (INIS)

    King, L.L.; Thatcher, C.D.; Clarke, J.D.; Rodriguez, M.P.

    1991-01-01

    During the past two decades the improvements in circuit integration have given rise to many new applications in digital processing technology by continuously reducing the unit cost of processing power. Along with this increase in processing power a corresponding decrease in circuit volume has been achieved. Progress has been so swift that new classes of applications become feasible every 2 or 3 years. This is especially true in the application of proven new technology to special nuclear materials (SNM) safeguard systems. Several areas of application were investigated in establishing the performance requirements for the SNM safeguard system. These included the improvements in material control and accountability and surveillance by using multiple sensors to continuously monitor SNM inventory within the selected value(s); establishing a system architecture to provide capabilities needed for present and future performance requirements; and limiting operating manpower exposure to radiation. This paper describes two selected topics in the application of state-of-the-art, well-proven technology to SNM safeguard system design

  4. [Evaluation of accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer].

    Science.gov (United States)

    Chen, X; Peng, D; Zhou, W; Zhong, Y

    1995-06-01

    To evaluate the accuracy of measuring intraocular pressure by handheld non-contact applanation tonometer. 58 patients' (113 eyes) intraocular pressure were measured by Keeler, non-contact tonometer and R 900 Goldmann applanation tonometer and the results of measurement of intraocular pressure by the two kinds of tonometers were compared. The mean intraocular pressure measured by non-contact is 16.31 +/- 5.59 mmHg and 17.49 +/- 6.13 mmHg (1 mmHg = 0.1333 kPa) by Goldmann applanation tonometer, respectively. There was no statistical significance to be found (P > 0.05) between the two methods. By linear correlation and regression analysis, a positive correlation was found between the two methods (r = 0.8942, b = 0.8154). The handheld non-contact tonometer has the same accuracy and reliability of measurement of intraocular pressure comparing with Goldmann applanation tonometer, and it can be used in glaucoma clinic and screening.

  5. Handheld pose tracking using vision-inertial sensors with occlusion handling

    Science.gov (United States)

    Li, Juan; Slembrouck, Maarten; Deboeverie, Francis; Bernardos, Ana M.; Besada, Juan A.; Veelaert, Peter; Aghajan, Hamid; Casar, José R.; Philips, Wilfried

    2016-07-01

    Tracking of a handheld device's three-dimensional (3-D) position and orientation is fundamental to various application domains, including augmented reality (AR), virtual reality, and interaction in smart spaces. Existing systems still offer limited performance in terms of accuracy, robustness, computational cost, and ease of deployment. We present a low-cost, accurate, and robust system for handheld pose tracking using fused vision and inertial data. The integration of measurements from embedded accelerometers reduces the number of unknown parameters in the six-degree-of-freedom pose calculation. The proposed system requires two light-emitting diode (LED) markers to be attached to the device, which are tracked by external cameras through a robust algorithm against illumination changes. Three data fusion methods have been proposed, including the triangulation-based stereo-vision system, constraint-based stereo-vision system with occlusion handling, and triangulation-based multivision system. Real-time demonstrations of the proposed system applied to AR and 3-D gaming are also included. The accuracy assessment of the proposed system is carried out by comparing with the data generated by the state-of-the-art commercial motion tracking system OptiTrack. Experimental results show that the proposed system has achieved high accuracy of few centimeters in position estimation and few degrees in orientation estimation.

  6. Radiation safety evaluation of a hand-held, battery operated image intensifier

    International Nuclear Information System (INIS)

    Wilson, O.J.; Young, B.F.

    1987-01-01

    A portable, hand-held, fluoroscopic unit intended for medical and industrial use was tested to verify the claim of the manufacturers that the radiation doses to the patient and user are low, and comparable to those received from standard radiographic procedures. The first claim was substantiated but not the second. A number of concerns arising from the use of this unit are discussed

  7. A BODIPY-Based Fluorescent Probe to Visually Detect Phosgene: Toward the Development of a Handheld Phosgene Detector.

    Science.gov (United States)

    Sayar, Melike; Karakuş, Erman; Güner, Tuğrul; Yildiz, Busra; Yildiz, Umit Hakan; Emrullahoğlu, Mustafa

    2018-03-02

    A boron-dipyrromethene (BODIPY)-based fluorescent probe with a phosgene-specific reactive motif shows remarkable selectivity toward phosgene, in the presence of which the nonfluorescent dye rapidly transforms into a new structure and induces a fluorescent response clearly observable to the naked eye under ultraviolet light. Given that dynamic, a prototypical handheld phosgene detector with a promising sensing capability that expedites the detection of gaseous phosgene without sophisticated instrumentation was developed. The proposed method using the handheld detector involves a rapid response period suitable for issuing early warnings during emergency situations. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Efficacy of Handheld Electronic Visual Supports to Enhance Vocabulary in Children with ASD

    Science.gov (United States)

    Ganz, Jennifer B.; Boles, Margot B.; Goodwyn, Fara D.; Flores, Margaret M.

    2014-01-01

    Although electronic tools such as handheld computers have become increasingly common throughout society, implementation of such tools to improve skills in individuals with intellectual and developmental disabilities has lagged in the professional literature. However, the use of visual scripts for individuals with disabilities, particularly those…

  9. A study of cladding technology on tube wall surface by a hand-held laser torch

    International Nuclear Information System (INIS)

    Terada, Takaya; Nishimura, Akihiko; Oka, Kiyoshi; Moriyama, Taku; Matsuda, Hiroyasu

    2015-01-01

    New maintenance technique was proposed using a hand-held laser torch for aging chemical plants and power plants. The hand-held laser torch was specially designed to be able to access limited tubular space in various cases. A composite-type optical fiberscope was composed of a center fiber for beam delivery and surrounded fibers for visible image delivery. Laser irradiation on a work pieces with the best accuracy of filler wire was carried out. And, we found that the optimized wire-feed speed was 2 mm/s in laser cladding. We succeeded to make a line clad on the inner wall of 23 mm tube. This technique was discussed to be applied to the maintenance for cracks or corrosions of tubes in various harsh environments. (author)

  10. Evolving Consumption Patterns of Various Information Media via Handheld Mobile Devices

    Directory of Open Access Journals (Sweden)

    Nitza Geri

    2015-06-01

    Full Text Available This study examines diverse information media in order to identify those formats that are most suitable for consumption via handheld mobile devices, namely, smartphones and tablets. The preferences of the users are measured objectively by analyzing actual data of their relative use of handheld mobile devices and personal computing (PC desktop devices, including laptops and notebooks, for consumption of information presented in various formats. Our findings are based on Google Analytics pageview data of five course Websites during a period of three semesters, by 11,557 undergraduate students. M-learning contexts were chosen, since in a learning environment the interests of information providers (i.e., the instructors are in accord with those of the information consumers (i.e., the students, whereas in commercial settings there may be conflicts of interests. Our findings demonstrate that although about 90% of the pageviews were via PC devices, the rate of smartphone use for consuming learning content in diverse information media is gradually increasing as time goes by, whereas the rate of tablet use for these purposes is stagnant. The most promising direction for smartphone development, emanating from the findings, is online video content.

  11. Hand-held indirect calorimeter offers advantages compared with prediction equations, in a group of overweight women, to determine resting energy expenditures and estimated total energy expenditures during research screening.

    Science.gov (United States)

    Spears, Karen E; Kim, Hyunsook; Behall, Kay M; Conway, Joan M

    2009-05-01

    To compare standardized prediction equations to a hand-held indirect calorimeter in estimating resting energy and total energy requirements in overweight women. Resting energy expenditure (REE) was measured by hand-held indirect calorimeter and calculated by prediction equations Harris-Benedict, Mifflin-St Jeor, World Health Organization/Food and Agriculture Organization/United Nations University (WHO), and Dietary Reference Intakes (DRI). Physical activity level, assessed by questionnaire, was used to estimate total energy expenditure (TEE). Subjects (n=39) were female nonsmokers older than 25 years of age with body mass index more than 25. Repeated measures analysis of variance, Bland-Altman plot, and fitted regression line of difference. A difference within +/-10% of two methods indicated agreement. Significant proportional bias was present between hand-held indirect calorimeter and prediction equations for REE and TEE (Pvalues and underestimated at higher values. Mean differences (+/-standard error) for REE and TEE between hand-held indirect calorimeter and Harris-Benedict were -5.98+/-46.7 kcal/day (P=0.90) and 21.40+/-75.7 kcal/day (P=0.78); between hand-held indirect calorimeter and Mifflin-St Jeor were 69.93+/-46.7 kcal/day (P=0.14) and 116.44+/-75.9 kcal/day (P=0.13); between hand-held indirect calorimeter and WHO were -22.03+/-48.4 kcal/day (P=0.65) and -15.8+/-77.9 kcal/day (P=0.84); and between hand-held indirect calorimeter and DRI were 39.65+/-47.4 kcal/day (P=0.41) and 56.36+/-85.5 kcal/day (P=0.51). Less than 50% of predictive equation values were within +/-10% of hand-held indirect calorimeter values, indicating poor agreement. A significant discrepancy between predicted and measured energy expenditure was observed. Further evaluation of hand-held indirect calorimeter research screening is needed.

  12. Advanced sampling techniques for hand-held FT-IR instrumentation

    Science.gov (United States)

    Arnó, Josep; Frunzi, Michael; Weber, Chris; Levy, Dustin

    2013-05-01

    FT-IR spectroscopy is the technology of choice to identify solid and liquid phase unknown samples. The challenging ConOps in emergency response and military field applications require a significant redesign of the stationary FT-IR bench-top instruments typically used in laboratories. Specifically, field portable units require high levels of resistance against mechanical shock and chemical attack, ease of use in restrictive gear, extreme reliability, quick and easy interpretation of results, and reduced size. In the last 20 years, FT-IR instruments have been re-engineered to fit in small suitcases for field portable use and recently further miniaturized for handheld operation. This article introduces the HazMatID™ Elite, a FT-IR instrument designed to balance the portability advantages of a handheld device with the performance challenges associated with miniaturization. In this paper, special focus will be given to the HazMatID Elite's sampling interfaces optimized to collect and interrogate different types of samples: accumulated material using the on-board ATR press, dispersed powders using the ClearSampler™ tool, and the touch-to-sample sensor for direct liquid sampling. The application of the novel sample swipe accessory (ClearSampler) to collect material from surfaces will be discussed in some detail. The accessory was tested and evaluated for the detection of explosive residues before and after detonation. Experimental results derived from these investigations will be described in an effort to outline the advantages of this technology over existing sampling methods.

  13. Xsense: using nanotechnology to combine detection methods for high sensitivity handheld explosives detectors

    DEFF Research Database (Denmark)

    Schmidt, Michael Stenbæk; Kostesha, Natalie; Bosco, Filippo

    2010-01-01

    In an effort to produce a handheld explosives sensor the Xsense project has been initiated at the Technical University of Denmark in collaboration with a number of partners. Using micro- and nano technological approaches it will be attempted to integrate four detection principles into a single de...

  14. Epidemiology of Handheld Cell Phone Use While Driving: A Study from a South Indian City.

    Science.gov (United States)

    Majgi, Sumanth Mallikarjuna; AiswaryaLakshmi, A S

    2018-01-01

    Using cell phones while driving contribute to distractions which can potentially cause minor or major road traffic injuries and also stress among other drivers. With this background, the study was done to ascertain the proportion of handheld cell phone use while driving among road users in Mysore city and also patterns of the use by the day of week, type of road, and type of vehicle. The study was conducted in Mysore, Karnataka, India. Four stretches of roads were observed thrice daily for 1 week. The total number of vehicles passing through the stretch and the number and characteristics of drivers using hand-held cell was noted. Pearson's Chi-square test was used to ascertain the significance of the difference in proportions. The overall proportion of cell phone users was calculated as 1.41/100 vehicles. The observed use of handheld cell phones was 1.78 times higher on nonbusy roads than busy roads ( Χ 2 = 25.79, P phone users were driving a two wheeler, the proportion being 50.5% in busy roads, and 67% in nonbusy roads. There was no difference in the proportion of cell phone use by time of the day or across different days of the week. The proportion of drivers who use cell phones is found to be relatively lower, and use of cell phones was higher on nonbusy roads.

  15. Balancing fast-rotating parts of hand-held machine drive

    Science.gov (United States)

    Korotkov, V. S.; Sicora, E. A.; Nadeina, L. V.; Yongzheng, Wang

    2018-03-01

    The article considers the issues related to the balancing of fast rotating parts of the hand-held machine drive including a wave transmission with intermediate rolling elements, which is constructed on the basis of the single-phase collector motor with a useful power of 1 kW and a nominal rotation frequency of 15000 rpm. The forms of balancers and their location are chosen. The method of balancing is described. The scheme for determining of residual unbalance in two correction planes is presented. Measurement results are given in tables.

  16. Comparison of Wearable Optical See-through and Handheld Devices as Platform for an Augmented Reality Museum Guide

    DEFF Research Database (Denmark)

    Serubugo, Sule; Skantarova, Denisa; Nielsen, Lasse Kjærsgård

    2017-01-01

    Self-service guides are a common way of providing information about artworks exhibited in museums. Modern advances in handheld mobile applications and wearable optical see-through devices that use augmented reality offer new ways of designing museum guides that are more engaging and interactive...... than traditional self-service guides such as written descriptions or audio guides. In this study we compare wearable (smart glasses) and handheld (smartphone) devices as a platform for an augmented reality museum guide. We have developed a museum guide for both a smartphone and smart glasses that can...... of potentials of these platforms as augmented reality museum guides and suggest promising future work....

  17. Hand-held cell phone use while driving legislation and observed driver behavior among population sub-groups in the United States

    OpenAIRE

    Rudisill, Toni M.; Zhu, Motao

    2017-01-01

    Abstract Background Cell phone use behaviors are known to vary across demographic sub-groups and geographic locations. This study examined whether universal hand-held calling while driving bans were associated with lower road-side observed hand-held cell phone conversations across drivers of different ages (16–24, 25–59, ≥60 years), sexes, races (White, African American, or other), ruralities (suburban, rural, or urban), and regions (Northeast, Midwest, South, and West). Methods Data from the...

  18. Spectroscopic monitoring of NO traces in plants and human breath: applications and perspectives

    DEFF Research Database (Denmark)

    Cristescu, S M; Marchenko, D; Mandon, J

    2012-01-01

    monitoring of NO concentrations in exhaled breath, and from plants under pathogen attack. A simple hand-held breath sampling device that allows single breath collection at various exhalation flows (15, 50, 100 and 300mL/s, respectively) is developed for off-line measurements and validated in combination...... with the WMS-based sensor. Additionally, the capability of plants to remove environmental NO is presented....

  19. Effects of a Driver Cellphone Ban on Overall, Handheld, and Hands-Free Cellphone Use While Driving: New Evidence from Canada.

    Science.gov (United States)

    Carpenter, Christopher S; Nguyen, Hai V

    2015-11-01

    We provide new evidence on the effects of increasingly common driver cellphone bans on self-reported overall, handheld, and hands-free cellphone use while driving by studying Ontario, Canada, which instituted a 3-month education campaign in November 2009 followed by a binding driver cellphone ban in February 2010. Using residents of Alberta as a control group in a difference-in-differences framework, we find visual and regression-based evidence that Ontario's cellphone ban significantly reduced overall and handheld cellphone use. We also find that the policies significantly increased hands-free cellphone use. The reductions in overall and handheld use are driven exclusively by women, whereas the increases in hands-free use are much larger for men. Our results provide the first direct evidence that cellphone bans have the unintended effect of inducing substitution to hands-free devices. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Rapid and automatic chemical identification of the medicinal flower buds of Lonicera plants by the benchtop and hand-held Fourier transform infrared spectroscopy

    Science.gov (United States)

    Chen, Jianbo; Guo, Baolin; Yan, Rui; Sun, Suqin; Zhou, Qun

    2017-07-01

    With the utilization of the hand-held equipment, Fourier transform infrared (FT-IR) spectroscopy is a promising analytical technique to minimize the time cost for the chemical identification of herbal materials. This research examines the feasibility of the hand-held FT-IR spectrometer for the on-site testing of herbal materials, using Lonicerae Japonicae Flos (LJF) and Lonicerae Flos (LF) as examples. Correlation-based linear discriminant models for LJF and LF are established based on the benchtop and hand-held FT-IR instruments. The benchtop FT-IR models can exactly recognize all articles of LJF and LF. Although a few LF articles are misjudged at the sub-class level, the hand-held FT-IR models are able to exactly discriminate LJF and LF. As a direct and label-free analytical technique, FT-IR spectroscopy has great potential in the rapid and automatic chemical identification of herbal materials either in laboratories or in fields. This is helpful to prevent the spread and use of adulterated herbal materials in time.

  1. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by ...

  2. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    Science.gov (United States)

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  3. Hand-held tidal breathing nasal nitric oxide measurement--a promising targeted case-finding tool for the diagnosis of primary ciliary dyskinesia

    DEFF Research Database (Denmark)

    Marthin, June Kehlet; Nielsen, Kim Gjerum

    2013-01-01

    BACKGROUND: Nasal nitric oxide (nNO) measurement is an established first line test in the work-up for primary ciliary dyskinesia (PCD). Tidal breathing nNO (TB-nNO) measurements require minimal cooperation and are potentially useful even in young children. Hand-held NO devices are becoming...... increasingly widespread for asthma management. Therefore, we chose to assess whether hand-held TB-nNO measurements reliably discriminate between PCD, and Healthy Subjects (HS) and included Cystic Fibrosis (CF) patients as a disease control group known to have intermediate nNO levels. METHODS: In this cross...... sectional, single centre, single occasion, proof-of-concept study in children and adults with PCD and CF, and in HS we compared feasibility, success rates, discriminatory capacity, repeatability and agreement between a hand-held electrochemical device equipped with a nNO software application sampling...

  4. Survey reveals public open to ban on hand-held cell phone use and texting.

    Science.gov (United States)

    2013-01-01

    A study performed by the Bureau of Transportation Statistics (BTS) reveals that the public is open to a ban on hand-held cell phone use while driving. The study is based on data from 2009s Omnibus Household Survey (OHS), which is administered by B...

  5. Algorithms for a hand-held miniature x-ray fluorescence analytical instrument

    International Nuclear Information System (INIS)

    Elam, W.T.; Newman, D.; Ziemba, F.

    1998-01-01

    The purpose of this joint program was to provide technical assistance with the development of a Miniature X-ray Fluorescence (XRF) Analytical Instrument. This new XRF instrument is designed to overcome the weaknesses of spectrometers commercially available at the present time. Currently available XRF spectrometers (for a complete list see reference 1) convert spectral information to sample composition using the influence coefficients technique or the fundamental parameters method. They require either a standard sample with composition relatively close to the unknown or a detailed knowledge of the sample matrix. They also require a highly-trained operator and the results often depend on the capabilities of the operator. In addition, almost all existing field-portable, hand-held instruments use radioactive sources for excitation. Regulatory limits on such sources restrict them such that they can only provide relatively weak excitation. This limits all current hand-held XRF instruments to poor detection limits and/or long data collection times, in addition to the licensing requirements and disposal problems for radioactive sources. The new XRF instrument was developed jointly by Quantrad Sensor, Inc., the Naval Research Laboratory (NRL), and the Department of Energy (DOE). This report describes the analysis algorithms developed by NRL for the new instrument and the software which embodies them

  6. Learning Motivation and Adaptive Video Caption Filtering for EFL Learners Using Handheld Devices

    Science.gov (United States)

    Hsu, Ching-Kun

    2015-01-01

    The aim of this study was to provide adaptive assistance to improve the listening comprehension of eleventh grade students. This study developed a video-based language learning system for handheld devices, using three levels of caption filtering adapted to student needs. Elementary level captioning excluded 220 English sight words (see Section 1…

  7. Remote real-time monitoring of subsurface landfill gas migration.

    Science.gov (United States)

    Fay, Cormac; Doherty, Aiden R; Beirne, Stephen; Collins, Fiachra; Foley, Colum; Healy, John; Kiernan, Breda M; Lee, Hyowon; Maher, Damien; Orpen, Dylan; Phelan, Thomas; Qiu, Zhengwei; Zhang, Kirk; Gurrin, Cathal; Corcoran, Brian; O'Connor, Noel E; Smeaton, Alan F; Diamond, Dermot

    2011-01-01

    The cost of monitoring greenhouse gas emissions from landfill sites is of major concern for regulatory authorities. The current monitoring procedure is recognised as labour intensive, requiring agency inspectors to physically travel to perimeter borehole wells in rough terrain and manually measure gas concentration levels with expensive hand-held instrumentation. In this article we present a cost-effective and efficient system for remotely monitoring landfill subsurface migration of methane and carbon dioxide concentration levels. Based purely on an autonomous sensing architecture, the proposed sensing platform was capable of performing complex analytical measurements in situ and successfully communicating the data remotely to a cloud database. A web tool was developed to present the sensed data to relevant stakeholders. We report our experiences in deploying such an approach in the field over a period of approximately 16 months.

  8. EMMNet: Sensor Networking for Electricity Meter Monitoring

    Directory of Open Access Journals (Sweden)

    Zhi-Ting Lin

    2010-06-01

    Full Text Available Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  9. EMMNet: sensor networking for electricity meter monitoring.

    Science.gov (United States)

    Lin, Zhi-Ting; Zheng, Jie; Ji, Yu-Sheng; Zhao, Bao-Hua; Qu, Yu-Gui; Huang, Xu-Dong; Jiang, Xiu-Fang

    2010-01-01

    Smart sensors are emerging as a promising technology for a large number of application domains. This paper presents a collection of requirements and guidelines that serve as a basis for a general smart sensor architecture to monitor electricity meters. It also presents an electricity meter monitoring network, named EMMNet, comprised of data collectors, data concentrators, hand-held devices, a centralized server, and clients. EMMNet provides long-distance communication capabilities, which make it suitable suitable for complex urban environments. In addition, the operational cost of EMMNet is low, compared with other existing remote meter monitoring systems based on GPRS. A new dynamic tree protocol based on the application requirements which can significantly improve the reliability of the network is also proposed. We are currently conducting tests on five networks and investigating network problems for further improvements. Evaluation results indicate that EMMNet enhances the efficiency and accuracy in the reading, recording, and calibration of electricity meters.

  10. Hand-held spectrophotometer design for textile fabrics

    Science.gov (United States)

    Böcekçi, Veysel Gökhan; Yıldız, Kazım

    2017-09-01

    In this study, a hand-held spectrophotometer was designed by taking advantage of the developments in modern optoelectronic technology. Spectrophotometer devices are used to determine the color information from the optic properties of the materials. As an alternative to a desktop spectrophotometer device we have implemented, it is the first prototype, low cost and portable. The prototype model designed for the textile industry can detect the color tone of any fabric. The prototype model consists of optic sensor, processor, display floors. According to the color applied on the optic sensor, it produces special frequency information on its output at that color value. In Arduino type processor, the frequency information is evaluated by the program we have written and the color tone information between 0-255 ton is decided and displayed on the screen.

  11. Exploring field-of-view non-uniformities produced by a hand-held spectroradiometer

    Directory of Open Access Journals (Sweden)

    Tamir Caras

    2011-01-01

    Full Text Available The shape of a spectroradiometer’s field of view (FOV affects the way spectral measurements are acquired. Knowing this property is a prerequisite for the correct use of the spectrometer. If the substrate is heterogeneous, the ability to accurately know what is being measured depends on knowing the FOV location, shape, spectral and spatial sensitivity. The GER1500 is a hand-held spectrometer with a fixed lens light entry slit and has a laser guide that allows control over the target by positioning the entire unit. In the current study, the FOV of the GER1500 was mapped and analysed. The spectral and spatial non-uniformities of the FOV were examined and were found to be spectrally independent. The relationship between the FOV and the built-in laser guide was tested and found to have a linear displacement dependent on the distance to the target. This allows an accurate prediction of the actual FOV position. A correction method to improve the agreement between the expected and measured reflectance over heterogeneous targets was developed and validated. The methods described are applicable and may be of use with other hand-held spectroradiometers.

  12. 75 FR 43206 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-07-23

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-706] In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld Devices and Battery Packs: Notice of Commission... United States after importation of certain wireless communications system server software, wireless...

  13. Applying Hand-Held 3D Printing Technology to the Teaching of VSEPR Theory

    Science.gov (United States)

    Dean, Natalie L.; Ewan, Corrina; McIndoe, J. Scott

    2016-01-01

    The use of hand-held 3D printing technology provides a unique and engaging approach to learning VSEPR theory by enabling students to draw three-dimensional depictions of different molecular geometries, giving them an appreciation of the shapes of the building blocks of complex molecular structures. Students are provided with 3D printing pens and…

  14. Rich internet application system for patient-centric healthcare data management using handheld devices.

    Science.gov (United States)

    Constantinescu, L; Pradana, R; Kim, J; Gong, P; Fulham, Michael; Feng, D

    2009-01-01

    Rich Internet Applications (RIAs) are an emerging software platform that blurs the line between web service and native application, and is a powerful tool for handheld device deployment. By democratizing health data management and widening its availability, this software platform has the potential to revolutionize telemedicine, clinical practice, medical education and information distribution, particularly in rural areas, and to make patient-centric medical computing a reality. In this paper, we propose a telemedicine application that leverages the ability of a mobile RIA platform to transcode, organise and present textual and multimedia data, which are sourced from medical database software. We adopted a web-based approach to communicate, in real-time, with an established hospital information system via a custom RIA. The proposed solution allows communication between handheld devices and a hospital information system for media streaming with support for real-time encryption, on any RIA enabled platform. We demonstrate our prototype's ability to securely and rapidly access, without installation requirements, medical data ranging from simple textual records to multi-slice PET-CT images and maximum intensity (MIP) projections.

  15. Discrimination of Pigments of Microalgae, Bacteria and Yeasts Using Lightweight Handheld Raman Spectrometers: Prospects for Astrobiology

    Science.gov (United States)

    Jehlicka, J.; Osterrothova, K.; Nedbalova, L.; Gunde-Cimerman, N.; Oren, A.

    2014-06-01

    Handheld Raman instrumentation with 532 nm lasers can be used to distinguish carotenoids of autotrophic microalgae, purple sulfur bacteria, halophilic Archaea and pigmented yeasts. Pigments are proposed as biomarkers for astrobiology of Mars.

  16. Compact handheld low-cost biosensor platform for remote health monitoring

    Science.gov (United States)

    Hastanin, J.; Lenaerts, C.; Gailly, P.; Jans, H.; Huang, C.; Lagae, L.; Kokkinos, D.; Fleury-Frenette, K.

    2016-04-01

    In this paper, we present an original concept of plasmonic-related instrumentation platform dedicated to diagnostic biosensing tests out of the laboratory. The developed instrumental platform includes both disposable one-use microfluidic affinity biochip and compact optical readout device for biochip monitoring involving mobile Internet devices for data processing and communication. The biochip includes both microfluidic and optical coupling structures formed into a single plastic slab. The microfluidic path of the biochip operates in passive capillary pumping mode. In the proof-of-concept prototype, we address specifically the sensing format involving Surface Plasmon Resonance phenomenon. The biochip is plugged in the readout device without the use of an index matching fluid. An essential advantage of the developed biochip is that its implementation involves conventional hot embossing and thin film deposition process, perfectly suited for mass production of low-cost microfluidic biochip for biochemical applications.

  17. Elbow joint position sense after neuromuscular training with handheld vibration.

    Science.gov (United States)

    Tripp, Brady L; Faust, Donald; Jacobs, Patrick

    2009-01-01

    Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Crossover study. University athletic training research laboratory. Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 + or - 3 years, height = 173 + or - 8 cm, mass = 76 + or - 14 kg). We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90 degrees ) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P or = .200). Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury.

  18. A Study of the Use of a Handheld Computer Algebra System in Discrete Mathematics

    Science.gov (United States)

    Powers, Robert A.; Allison, Dean E.; Grassl, Richard M.

    2005-01-01

    This study investigated the impact of the TI-92 handheld Computer Algebra System (CAS) on student achievement in a discrete mathematics course. Specifically, the researchers examined the differences between a CAS section and a control section of discrete mathematics on students' in-class examinations. Additionally, they analysed student approaches…

  19. Comparing handheld and hands-free cell phone usage behaviors while driving.

    Science.gov (United States)

    Soccolich, Susan A; Fitch, Gregory M; Perez, Miguel A; Hanowski, Richard J

    2014-01-01

    The goal of this study was to compare cell phone usage behaviors while driving across 3 types of cell phones: handheld (HH) cell phones, portable hands-free (PHF) cell phones, and integrated hands-free (IHF) cell phones. Naturalistic driving data were used to observe HH, PHF, and IHF usage behaviors in participants' own vehicles without any instructions or manipulations by researchers. In addition to naturalistic driving data, drivers provided their personal cell phone call records. Calls during driving were sampled and observed in naturalistically collected video. Calls were reviewed to identify cell phone type used for, and duration of, cell phone subtasks, non-cell phone secondary tasks, and other use behaviors. Drivers in the study self-identified as HH, PHF, or IHF users if they reported using that cell phone type at least 50% of the time. However, each sampled call was classified as HH, PHF, or IHF if the talking/listening subtask was conducted using that cell phone type, without considering the driver's self-reported group. Drivers with PHF or IHF systems also used HH cell phones (IHF group used HH cell phone in 53.2% of the interactions, PHF group used HH cell phone for 55.5% of interactions). Talking/listening on a PHF phone or an IHF phone was significantly longer than talking/listening on an HH phone (P phone call task for HH phones was significantly longer in duration than the end phone call task for PHF and IHF phones. Of all the non-cell phone-related secondary tasks, eating or drinking was found to occur significantly more often during IHF subtasks (0.58%) than in HH subtasks (0.15%). Drivers observed to reach for their cell phone mostly kept their cell phone in the cup holder (36.3%) or in their seat or lap (29.0% of interactions); however, some observed locations may have required drivers to move out of position. Hands-free cell phone technologies reduce the duration of cell phone visual-manual tasks compared to handheld cell phones. However

  20. Technological characteristics of digital video broadcasting: Handheld standard DVB-H

    Directory of Open Access Journals (Sweden)

    Andreja B. Samčović

    2011-07-01

    Full Text Available This paper gives an overview of the Digital Video Broadcasting - Handheld standard DVB-H, as a part of the DVB Project. This standard is based on the previous standard DVB-T, which was developed for the terrestrial digital television. The ways of DVB-H signal transmission are also described. Development of advanced technology enabled the digital video broadcasting over wireless portable terminals. This paper discusses the key technological features of the DVB-H standard, such as: time slicing, forward error correction, 4K mode and in-depth interleavers.

  1. 75 FR 10502 - In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices...

    Science.gov (United States)

    2010-03-08

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-667; Investigation No. 337-TA-673] In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices; Notice of... Entirety AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that...

  2. The 21st century Museum Climatic Monitoring System

    Science.gov (United States)

    Liu, W.-S.

    2015-08-01

    Technology has provided us work convenience and shaped our quality of life; it has enabled an unprecedented level of access to knowledge by flipping screen of a hand-held electronic device without going elsewhere but stay connected wireless communication. This kind of technology has been broadly acquired at museums in Hong Kong for preserving their valuable collections. Similar gadget was applied on the monitoring system to record climatic conditions of museum's stores and galleries. Sensors have been equipped with chips for the wireless transmission of RH/Temp, without installation of any conduit or LAN lines. Useful and important data will then be grouped into a packet format for efficient delivery. As long as the static IP address of the target workstation has been set, data can be accurately retrieved from one place to another via commercially available browsers, such as: Firefox or Internet Explorer, even on hand-held electronic devices. This paper will discuss the detail of this system, its pros and cons in comparison with the old model. After all, the new technology is highly significant in supporting the current needs and the future developments of the museum service.

  3. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    Energy Technology Data Exchange (ETDEWEB)

    Ortega, Joaquin; Lledo, Salvador [University of Valencia, Clinic University Hospital, Department of Surgery, Valencia (Spain); Ferrer-Rebolleda, Jose [Clinic University Hospital, Department of Nuclear Medicine, Valencia (Spain); Cassinello, Norberto [Clinic University Hospital, Unit of Endocrinologic and Bariatric Surgery, Valencia (Spain)

    2007-02-15

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  4. Potential role of a new hand-held miniature gamma camera in performing minimally invasive parathyroidectomy

    International Nuclear Information System (INIS)

    Ortega, Joaquin; Lledo, Salvador; Ferrer-Rebolleda, Jose; Cassinello, Norberto

    2007-01-01

    Sestamibi scans have increased the use of minimally invasive parathyroidectomy (MIP) to treat primary hyperparathyroidism (PHPT) when caused by a parathyroid single adenoma. The greatest concern for surgeons remains the proper identification of pathological glands in a limited surgical field. We have studied the usefulness of a new hand-held miniature gamma camera (MGC) when used intraoperatively to locate parathyroid adenomas. To our knowledge this is the first report published on this subject in the scientific literature. Five patients with PHPT secondary to a single adenoma, positively diagnosed by preoperative sestamibi scans, underwent a MIP. A gamma probe for radioguided surgery and the new hand-held MGC were used consecutively to locate the pathological glands. This new MGC has a module composed of a high-resolution interchangeable collimator and a CsI(Na) scintillating crystal. It has dimensions of around 15 cm x 8 cm x 9 cm and weighs 1 kg. The intraoperative assay of PTH (ioPTH) was used to confirm the complete resection of pathological tissue. All cases were operated on successfully by a MIP. The ioPTH confirmed the excision of all pathological tissues. The MGC proved its usefulness in all patients, even in a difficult case in which the first attempt with the gamma probe failed. In all cases it offered real-time accurate intraoperative images. The hand-held MGC is a useful instrument in MIP for PHPT. It may be used to complement the standard tools used to date, or may even replace them, at least in selected cases of single adenomas. (orig.)

  5. Strength and Pain Threshold Handheld Dynamometry Test Reliability in Patellofemoral Pain.

    Science.gov (United States)

    van der Heijden, R A; Vollebregt, T; Bierma-Zeinstra, S M A; van Middelkoop, M

    2015-12-01

    Patellofemoral pain syndrome (PFPS), characterized by peri- and retropatellar pain, is a common disorder in young, active people. The etiology is unclear; however, quadriceps strength seems to be a contributing factor, and sensitization might play a role. The study purpose is determining the inter-rater reliability of handheld dynamometry to test both quadriceps strength and pressure pain threshold (PPT), a measure for sensitization, in patients with PFPS. This cross-sectional case-control study comprises 3 quadriceps strength and one PPT measurements performed by 2 independent investigators in 22 PFPS patients and 16 matched controls. Inter-rater reliability was analyzed using intraclass correlation coefficients (ICC) and Bland-Altman plots. Inter-rater reliability of quadriceps strength testing was fair to good in PFPS patients (ICC=0.72) and controls (ICC=0.63). Bland-Altman plots showed an increased difference between assessors when average quadriceps strength values exceeded 250 N. Inter-rater reliability of PPT was excellent in patients (ICC=0.79) and fair to good in controls (ICC=0.52). Handheld dynamometry seems to be a reliable method to test both quadriceps strength and PPT in PFPS patients. Inter-rater reliability was higher in PFPS patients compared to control subjects. With regard to quadriceps testing, a higher variance between assessors occurs when quadriceps strength increases. © Georg Thieme Verlag KG Stuttgart · New York.

  6. A handheld open-field infant keratometer (an american ophthalmological society thesis).

    Science.gov (United States)

    Miller, Joseph M

    2010-12-01

    To design and evaluate a new infant keratometer that incorporates an unobstructed view of the infant with both eyes (open-field design). The design of the open-field infant keratometer is presented, and details of its construction are given. The design incorporates a single-ring keratoscope for measurement of corneal astigmatism over a 4-mm region of the cornea and includes a rectangular grid target concentric within the ring to allow for the study of higher-order aberrations of the eye. In order to calibrate the lens and imaging system, a novel telecentric test object was constructed and used. The system was bench calibrated against steel ball bearings of known dimensions and evaluated for accuracy while being used in handheld mode in a group of 16 adult cooperative subjects. It was then evaluated for testability in a group of 10 infants and toddlers. Results indicate that while the device achieved the goal of creating an open-field instrument containing a single-ring keratoscope with a concentric grid array for the study of higher-order aberrations, additional work is required to establish better control of the vertex distance. The handheld open-field infant keratometer demonstrates testability suitable for the study of infant corneal astigmatism. Use of collimated light sources in future iterations of the design must be incorporated in order to achieve the accuracy required for clinical investigation.

  7. Absorption Related to Hand-Held Devices in Data Mode

    DEFF Research Database (Denmark)

    Andersen, Jørgen Bach; Nielsen, Jesper Ødum; Pedersen, Gert F.

    2016-01-01

    The human body has an influence on the radiation from handheld devices like smartphones, tablets and laptops, part of the energy is absorbed and the spatial distribution of the radiated part is modified. Previous studies of whole body absorp- tion have mainly been numerical or related to talk mode....... In the present paper an experimental study involving four volunteers and three different devices is performed from 0.5 to 3 GHz. The devices are a laptop, a tablet, and a smartphone all held in the lap. The 3D distribution of radiation is measured. Comparing the integrated power in the case of a person present...

  8. A sensitive, handheld vapor sensor based on microcantilevers

    Science.gov (United States)

    Pinnaduwage, L. A.; Hedden, D. L.; Gehl, A.; Boiadjiev, V. I.; Hawk, J. E.; Farahi, R. H.; Thundat, T.; Houser, E. J.; Stepnowski, S.; McGill, R. A.; Deel, L.; Lareau, R. T.

    2004-11-01

    We report the development of a handheld sensor based on piezoresistive microcantilevers that does not depend on optical detection, yet has high detection sensitivity. The sensor is able to detect vapors from the plastic explosives pentaerythritol tetranitrate and hexahydro-1,3,5-triazine at levels below 10 parts per trillion within few seconds of exposure under ambient conditions. A differential measurement technique has yielded a rugged sensor that is unaffected by vibration and is able to function as a "sniffer." The microelectromechanical system sensor design allows for the incorporation of hundreds of microcantilevers with suitable coatings in order to achieve sufficient selectivity in the future, and thus could provide an inexpensive, unique platform for the detection of chemical, biological, and explosive materials.

  9. A handheld optical device for skin profile measurement

    Science.gov (United States)

    Sun, Jiuai; Liu, Xiaojin

    2018-04-01

    This paper describes a portable optical scanning device designed for skin surface measurement on both colour and 3D geometry through a relative easy and cost effective multiple light source photometric stereo method. The validation of colour recovered had been verified through its application on skin lesion segmentation in our early work. This paper focuses on the reconstructed topographic data which are subject to further evaluation and advancement. The evaluation work takes the skin in vitro as an application scenario and compares the experimental result to that obtained by using a commercial product. The experiments show that this handheld device can measure the skin profile significantly closer to that of the ground truth and have the additional function of skin colour recovery.

  10. Contact lens assisted imaging with integrated flexible handheld probe for glaucoma diagnosis

    Science.gov (United States)

    Hong, Xun Jie Jeesmond; V. K., Shinoj; Murukeshan, V. M.; Baskaran, M.; Aung, Tin

    2017-06-01

    Angle closure glaucoma accounts for majority of the bilateral blindness in Asian countries such as Singapore, China, and India. Abnormalities in the optic nerve and aqueous outflow system are the most indicative clinical hallmarks for glaucoma of this clinical subtype. Traditional photographic imaging techniques to assess the drainage angle are contact based, and may expose patients to risk of corneal abrasion and infections. In addition, these procedures require the use of viscous ophthalmic gels as coupling medium to overcome the phenomenon of total internal reflection at the tear-air interface. In this paper, we propose an integrated flexible handheld probe consisting of a micro color CCD video camera and white light LEDs. The handheld probe is able to capture images of the fundus and opposite iridocorneal angle when placed at the central cornea or limbus respectively. Here, we propose the use of hydrogel contact lens as an index matching medium and better protective barrier, as an alternative to conventional ophthalmic gels. The proposed imaging system and methodology has been successfully tested on porcine eye samples, ex vivo. With its high repeatability, reproducibility, and a good safety profile, it is believed that the proposed imaging system and methodology will complement existing imaging modalities in the diagnosis and management of glaucoma.

  11. Use of handheld X-ray fluorescence spectrometry units for identification of arsenic in treated wood

    Energy Technology Data Exchange (ETDEWEB)

    Block, Colleen N. [University of Miami, Department of Civil, Architectural, and Environmental Engineering, P.O. Box 248294, McArthur Building, Coral Gables, FL 33124-0630 (United States); Shibata, Tomoyuki [University of Miami, Department of Civil, Architectural, and Environmental Engineering, P.O. Box 248294, McArthur Building, Coral Gables, FL 33124-0630 (United States); Solo-Gabriele, Helena M. [University of Miami, Department of Civil, Architectural, and Environmental Engineering, P.O. Box 248294, McArthur Building, Coral Gables, FL 33124-0630 (United States)]. E-mail: hmsolo@miami.edu; Townsend, Timothy G. [University of Florida, Department of Environmental Engineering Sciences, Gainesville, FL 32611-6450 (United States)

    2007-07-15

    The objective of this study was to evaluate the performance of handheld XRF analyzers on wood that has been treated with a preservative containing arsenic. Experiments were designed to evaluate precision, detection limit, effective depth of analysis, and accuracy of the XRF arsenic readings. Results showed that the precision of the XRF improved with increased sample concentration and longer analysis times. Reported detection limits decreased with longer analysis times to values of less than 1 mg/kg or 18 mg/kg, depending on the model used. The effective depth of analysis was within the top 1.2 cm and 2.0 cm of sample for wood containing natural gradients of chemical preservative and concentration extremes, respectively. XRF results were found to be 1.5-2.3 times higher than measurements from traditional laboratory analysis. Equations can be developed to convert XRF values to results which are consistent with traditional laboratory testing. - Handheld XRF analyzers provided quantitative results for the amount of arsenic within preservative-treated wood.

  12. Handheld ultrahigh speed swept source optical coherence tomography instrument using a MEMS scanning mirror.

    Science.gov (United States)

    Lu, Chen D; Kraus, Martin F; Potsaid, Benjamin; Liu, Jonathan J; Choi, Woojhon; Jayaraman, Vijaysekhar; Cable, Alex E; Hornegger, Joachim; Duker, Jay S; Fujimoto, James G

    2013-12-20

    We developed an ultrahigh speed, handheld swept source optical coherence tomography (SS-OCT) ophthalmic instrument using a 2D MEMS mirror. A vertical cavity surface-emitting laser (VCSEL) operating at 1060 nm center wavelength yielded a 350 kHz axial scan rate and 10 µm axial resolution in tissue. The long coherence length of the VCSEL enabled a 3.08 mm imaging range with minimal sensitivity roll-off in tissue. Two different designs with identical optical components were tested to evaluate handheld OCT ergonomics. An iris camera aided in alignment of the OCT beam through the pupil and a manual fixation light selected the imaging region on the retina. Volumetric and high definition scans were obtained from 5 undilated normal subjects. Volumetric OCT data was acquired by scanning the 2.4 mm diameter 2D MEMS mirror sinusoidally in the fast direction and linearly in the orthogonal slow direction. A second volumetric sinusoidal scan was obtained in the orthogonal direction and the two volumes were processed with a software algorithm to generate a merged motion-corrected volume. Motion-corrected standard 6 x 6 mm(2) and wide field 10 x 10 mm(2) volumetric OCT data were generated using two volumetric scans, each obtained in 1.4 seconds. High definition 10 mm and 6 mm B-scans were obtained by averaging and registering 25 B-scans obtained over the same position in 0.57 seconds. One of the advantages of volumetric OCT data is the generation of en face OCT images with arbitrary cross sectional B-scans registered to fundus features. This technology should enable screening applications to identify early retinal disease, before irreversible vision impairment or loss occurs. Handheld OCT technology also promises to enable applications in a wide range of settings outside of the traditional ophthalmology or optometry clinics including pediatrics, intraoperative, primary care, developing countries, and military medicine.

  13. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination

    International Nuclear Information System (INIS)

    Paridaens, J.

    2006-01-01

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth[reg] GPS receiver, a commercial RS-232 to Bluetooth[reg] converter combined with a standard Bluetooth[reg] enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river

  14. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination.

    Science.gov (United States)

    Paridaens, J

    2006-02-01

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth GPS receiver, a commercial RS-232 to Bluetooth converter combined with a standard Bluetooth enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

  15. Development of a low cost, GPS-based upgrade to a standard handheld gamma detector for mapping environmental radioactive contamination

    Energy Technology Data Exchange (ETDEWEB)

    Paridaens, J. [Belgian Nuclear Research Centre, SCK.CEN, Boeretang 200, B2400 Mol (Belgium)]. E-mail: jparidae@sckcen.be

    2006-02-15

    A low cost extension to a standard handheld radiation monitor was developed, allowing one to perform outdoor georeferenced gamma measurements. It consists of a commercial wireless Bluetooth[reg] GPS receiver, a commercial RS-232 to Bluetooth[reg] converter combined with a standard Bluetooth[reg] enabled pocket personal computer (PPC). The system is intended for use in difficult to access areas, typically for foot campaigns. As the operator walks, a straightforward homemade visual basic program alternately reads GPS position and gamma dose rate into the PPC, creating a data log. This allows a single operator on foot to map between 50 and 200 ha of environmental radiation per day in very rugged areas, depending on the accessibility of the terrain and the detail required. On a test field with known contamination, a spatial precision of about 5-10 m was obtainable. The device was also used to reveal complex contamination patterns in the flooding zones of a radioactively contaminated small river.

  16. Fast, cheap and in control: spectral imaging with handheld devices

    Science.gov (United States)

    Gooding, Edward A.; Deutsch, Erik R.; Huehnerhoff, Joseph; Hajian, Arsen R.

    2017-05-01

    Remote sensing has moved out of the laboratory and into the real world. Instruments using reflection or Raman imaging modalities become faster, cheaper and more powerful annually. Enabling technologies include virtual slit spectrometer design, high power multimode diode lasers, fast open-loop scanning systems, low-noise IR-sensitive array detectors and low-cost computers with touchscreen interfaces. High-volume manufacturing assembles these components into inexpensive portable or handheld devices that make possible sophisticated decision-making based on robust data analytics. Examples include threat, hazmat and narcotics detection; remote gas sensing; biophotonic screening; environmental remediation and a host of other applications.

  17. Font size and viewing distance of handheld smart phones.

    Science.gov (United States)

    Bababekova, Yuliya; Rosenfield, Mark; Hue, Jennifer E; Huang, Rae R

    2011-07-01

    The use of handheld smart phones for written communication is becoming ubiquitous in modern society. The relatively small screens found in these devices may necessitate close working distances and small text sizes, which can increase the demands placed on accommodation and vergence. Font size and viewing distance were measured while subjects used handheld electronic devices in two separate trials. In the first study (n=129), subjects were asked to show a typical text message on their own personal phone and to hold the device "as if they were about to read a text message." A second trial was conducted in a similar manner except subjects (n=100) were asked to view a specific web page from the internet. For text messages and internet viewing, the mean font size was 1.1 M (range, 0.7 to 2.1 M) and 0.8 M (range, 0.3 to 1.4 M), respectively. The mean working distance for text messages and internet viewing was 36.2 cm (range, 17.5 to 58.0 cm) and 32.2 cm (range, 19 to 60 cm), respectively. The mean font size for both conditions was comparable with newspaper print, although some subjects viewed text that was considerably smaller. However, the mean working distances were closer than the typical near working distance of 40 cm for adults when viewing hardcopy text. These close distances place increased demands on both accommodation and vergence, which could exacerbate symptoms. Practitioners need to consider the closer distances adopted while viewing material on smart phones when examining patients and prescribing refractive corrections for use at near, as well as when treating patients presenting with asthenopia associated with nearwork. Copyright © 2011 American Academy of Optometry

  18. Pyxis handheld polarimetric imager

    Science.gov (United States)

    Chenault, David B.; Pezzaniti, J. Larry; Vaden, Justin P.

    2016-05-01

    The instrumentation for measuring infrared polarization signatures has seen significant advancement over the last decade. Previous work has shown the value of polarimetric imagery for a variety of target detection scenarios including detection of manmade targets in clutter and detection of ground and maritime targets while recent work has shown improvements in contrast for aircraft detection and biometric markers. These data collection activities have generally used laboratory or prototype systems with limitations on the allowable amount of target motion or the sensor platform and usually require an attached computer for data acquisition and processing. Still, performance and sensitivity have been steadily getting better while size, weight, and power requirements have been getting smaller enabling polarimetric imaging for a greater or real world applications. In this paper, we describe Pyxis®, a microbolometer based imaging polarimeter that produces live polarimetric video of conventional, polarimetric, and fused image products. A polarization microgrid array integrated in the optical system captures all polarization states simultaneously and makes the system immune to motion artifacts of either the sensor or the scene. The system is battery operated, rugged, and weighs about a quarter pound, and can be helmet mounted or handheld. On board processing of polarization and fused image products enable the operator to see polarimetric signatures in real time. Both analog and digital outputs are possible with sensor control available through a tablet interface. A top level description of Pyxis® is given followed by performance characteristics and representative data.

  19. Using handheld devices for real-time wireless teleconsultation.

    Science.gov (United States)

    Banitsas, K A; Georgiadis, P; Tachakra, S; Cavouras, D

    2004-01-01

    Recent advances in the hardware of handheld devices, opened up the way for newer applications in the healthcare sector, and more specifically, in the teleconsultation field. Out of these devices, this paper focuses on the services that personal digital assistants and smartphones can provide to improve the speed, quality and ease of delivering a medical opinion from a distance and laying the ground for an all-wireless hospital. In that manner, PDAs were used to wirelessly support the viewing of digital imaging and communication in medicine (DICOM) images and to allow for mobile videoconferencing while within the hospital. Smartphones were also used to carry still images, multiframes and live video outside the hospital. Both of these applications aimed at increasing the mobility of the consultant while improving the healthcare service.

  20. Spectral domain, common path OCT in a handheld PIC based system

    Science.gov (United States)

    Leinse, Arne; Wevers, Lennart; Marchenko, Denys; Dekker, Ronald; Heideman, René G.; Ruis, Roosje M.; Faber, Dirk J.; van Leeuwen, Ton G.; Kim, Keun Bae; Kim, Kyungmin

    2018-02-01

    Optical Coherence Tomography (OCT) has made it into the clinic in the last decade with systems based on bulk optical components. The next disruptive step will be the introduction of handheld OCT systems. Photonic Integrated Circuit (PIC) technology is the key enabler for this further miniaturization. PIC technology allows signal processing on a stable platform and the implementation of a common path interferometer in that same platform creates a robust fully integrated OCT system with a flexible fiber probe. In this work the first PIC based handheld and integrated common path based spectral domain OCT system is described and demonstrated. The spectrometer in the system is based on an Arrayed Waveguide Grating (AWG) and fully integrated with the CCD and a fiber probe into a system operating at 850 nm. The AWG on the PIC creates a 512 channel spectrometer with a resolution of 0.22 nm enabling a high speed analysis of the full A-scan. The silicon nitride based proprietary waveguide technology (TriPleXTM) enables low loss complex photonic structures from the visible (405 nm) to IR (2350 nm) range, making it a unique candidate for OCT applications. Broadband AWG operation from visible to 1700 nm has been shown in the platform and Photonic Design Kits (PDK) are available enabling custom made designs in a system level design environment. This allows a low threshold entry for designing new (OCT) designs for a broad wavelength range.

  1. The Xsense project: The application of an intelligent sensor array for high sensitivity handheld explosives detectors

    DEFF Research Database (Denmark)

    Kostesha, Natalie; Schmidt, Michael Stenbæk; Bosco, Filippo

    2011-01-01

    Multiple independent sensors are used in security and military applications in order to increase sensitivity, selectivity and data reliability. The Xsense project has been initiated at the Technical University of Denmark in collaboration with a number of partners in an effort to produce a handheld...

  2. Introducing Handheld Computing for Interactive Medical Education

    Directory of Open Access Journals (Sweden)

    Joseph Finkelstein

    2005-04-01

    Full Text Available The goals of this project were: (1 development of an interactive multimedia medical education tool (CO-ED utilizing modern features of handheld computing (PDA and major constructs of adult learning theories, and (2 pilot testing of the computer-assisted education in residents and clinicians. Comparison of the knowledge scores using paired t-test demonstrated statistically significant increase in subject knowledge (p<0.01 after using CO-ED. Attitudinal surveys were analyzed by total score (TS calculation represented as a percentage of a maximal possible score. The mean TS was 74.5±7.1%. None of the subjects (N=10 had TS less than 65% and in half of the subjects (N=5 TS was higher than 75%. Analysis of the semi-structured in-depth interviews showed strong support of the study subjects in using PDA as an educational tool, and high acceptance of CO-ED user interface. We concluded that PDA have a significant potential as a tool for clinician education.

  3. A handheld point-of-care genomic diagnostic system.

    Directory of Open Access Journals (Sweden)

    Frank B Myers

    Full Text Available The rapid detection and identification of infectious disease pathogens is a critical need for healthcare in both developed and developing countries. As we gain more insight into the genomic basis of pathogen infectivity and drug resistance, point-of-care nucleic acid testing will likely become an important tool for global health. In this paper, we present an inexpensive, handheld, battery-powered instrument designed to enable pathogen genotyping in the developing world. Our Microfluidic Biomolecular Amplification Reader (µBAR represents the convergence of molecular biology, microfluidics, optics, and electronics technology. The µBAR is capable of carrying out isothermal nucleic acid amplification assays with real-time fluorescence readout at a fraction of the cost of conventional benchtop thermocyclers. Additionally, the µBAR features cell phone data connectivity and GPS sample geotagging which can enable epidemiological surveying and remote healthcare delivery. The µBAR controls assay temperature through an integrated resistive heater and monitors real-time fluorescence signals from 60 individual reaction chambers using LEDs and phototransistors. Assays are carried out on PDMS disposable microfluidic cartridges which require no external power for sample loading. We characterize the fluorescence detection limits, heater uniformity, and battery life of the instrument. As a proof-of-principle, we demonstrate the detection of the HIV-1 integrase gene with the µBAR using the Loop-Mediated Isothermal Amplification (LAMP assay. Although we focus on the detection of purified DNA here, LAMP has previously been demonstrated with a range of clinical samples, and our eventual goal is to develop a microfluidic device which includes on-chip sample preparation from raw samples. The µBAR is based entirely around open source hardware and software, and in the accompanying online supplement we present a full set of schematics, bill of materials, PCB layouts

  4. A new approach for the screening of carotid lesions: a 'fast-track' method with the use of new generation hand-held ultrasound devices.

    Science.gov (United States)

    Aboyans, V; Lacroix, P; Jeannicot, A; Guilloux, J; Bertin, F; Laskar, M

    2004-09-01

    We assessed the usefulness of fast-track neck sonography with a new-generation hand-held ultrasound scanner in the detection of > or =60% carotid stenosis. Patients with a past history of atherosclerotic disease or presence of risk factors were enrolled. All had fast-track carotid screening with a hand-held ultrasound scanner. Initial assessment was performed with our quick imaging protocol. A second examiner performed a conventional complete carotid duplex as gold-standard. We enrolled 197 consecutive patients with a mean age of 67 years (range 35-94). A carotid stenosis >60% was detected in 13 cases (6%). The sensitivity, specificity, positive and negative predictive value of fast-track sonography was 100%, 64%, 17% and 100%, respectively. Concomitant power Doppler imaging during the fast-track method did not improve accuracy. The use of a fast-track method with a hand-held ultrasound device can reduce the number of unnecessary carotid Duplex and enhance the screening efficiency without missing significant carotid stenoses.

  5. A Mobile Mixed-Reality Environment for Children's Storytelling Using a Handheld Projector and a Robot

    Science.gov (United States)

    Sugimoto, Masanori

    2011-01-01

    This paper describes a system called GENTORO that uses a robot and a handheld projector for supporting children's storytelling activities. GENTORO differs from many existing systems in that children can make a robot play their own story in a physical space augmented by mixed-reality technologies. Pilot studies have been conducted to clarify the…

  6. Handheld Micromanipulator for Robot-Assisted Stapes Footplate Surgery

    Science.gov (United States)

    Grande, Gonzalo Montes; Knisely, Anna J.; Becker, Brian C.; Yang, Sungwook; Hirsch, Barry E.; Riviere, Cameron N.

    2012-01-01

    Stapes footplate surgery is complex and delicate. This surgery is carried out in the middle ear to improve hearing. High accuracy is required to avoid critical tissues and structures near the surgical worksite. By suppressing the surgeon’s tremor during the operation, accuracy can be improved. In this paper, a fully handheld active micromanipulator known as Micron is evaluated for its feasibility for this delicate operation. An ergonomic handle, a custom tip, and a brace attachment were designed for stapes footplate surgery and tested in a fenestration task through a fixed speculum. Accuracy was measured during simulated surgery in two different scenarios: Micron off (unaided) and Micron on (aided), both with image guidance. Preliminary results show that Micron significantly reduces the mean position error and the mean duration of time spent in specified dangerous zones. PMID:23366167

  7. An Integrated Passive (Battery-Free) Seals-and-Tag for International Safeguards

    International Nuclear Information System (INIS)

    Nekoogar, F.; Dowla, F.

    2015-01-01

    The ability to reliably and securely automate the monitoring of SNM is an important goal in Safeguards. Although item level monitoring of SNM requires both seal and tag technologies, the two technologies thus far have been developed more or less independently, and had been a lack of an integrated compact system. An integrated seal-and-tag approach not only aids inspectors to perform their tasks effectively, this approach also allows real-time inspection in large scale facilities. A typical facility could be the size of a large warehouse with hundreds or thousands of items that need to be sealed and monitored in real-time. Previously we reported on advanced secure RF passive (battery-less) tags with special features including, long-range interrogation of passive tags, communicating with passive tags with strong encryption and dynamic authentication features, and the ability to place the tags directly on metal objects. In this paper, we report on a novel secure passive tag integrated with fibre optics seal that allows real-time monitoring of items through secure wireless communications that employs AES encryption and dynamic authentication. Furthermore, the devices can be networked for large scale operations. The proposed passive seal has the same capabilities as active seals in that it allows realtime monitoring. However, the battery lifetimes of conventional active seals are limited or unpredictable. As the long-term storage of SNM might last for several years, these passive seals having been integrated with passive RF tags, extends the lifetime of the physical seals and tags indefinitely, while getting the same performance of active seals and tags. The integrated seal-and-tag is transformational in addressing a critical need in Safeguards area for long-term real-time monitoring. (author)

  8. 76 FR 22918 - In the Matter of Certain Handheld Electronic Computing Devices, Related Software, and Components...

    Science.gov (United States)

    2011-04-25

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-769] In the Matter of Certain Handheld Electronic.... International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that a complaint was filed with the U.S. International Trade Commission on March 21, 2011, under section 337 of the Tariff Act of 1930...

  9. A distribution-free test for anomalous gamma-ray spectra

    International Nuclear Information System (INIS)

    Chan, Kung-sik; Li, Jinzheng; Eichinger, William; Bai, Er-Wei

    2014-01-01

    Gamma-ray spectra are increasingly acquired in monitoring cross-border traffic, or in an area search for lost or orphan special nuclear material (SNM). The signal in such data is generally weak, resulting in poorly resolved spectra, thereby making it hard to detect the presence of SNM. We develop a new test for detecting anomalous spectra by characterizing the complete shape change in a spectrum from background radiation; the proposed method may serve as a tripwire for routine screening for SNM. We show that, with increasing detection time, the limiting distribution of the test is given by some functional of the Brownian bridge. The efficacy of the proposed method is illustrated by simulations. - Highlights: • We develop a new non-parametric test for detecting anomalous gamma-ray spectra. • The proposed test has good empirical power for detecting weak signals. • It can serve as an effective tripwire for invoking more thorough scrutiny of the source

  10. Comparative Geometrical Investigations of Hand-Held Scanning Systems

    Science.gov (United States)

    Kersten, T. P.; Przybilla, H.-J.; Lindstaedt, M.; Tschirschwitz, F.; Misgaiski-Hass, M.

    2016-06-01

    An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry) as well as the Humboldt University in Berlin (Institute for Computer Science): DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google's Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M). The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  11. Intra-operative ultrasound hand-held strain imaging for the visualization of ablations produced in the liver with a toroidal HIFU transducer: first in vivo results

    Energy Technology Data Exchange (ETDEWEB)

    Chenot, J; Melodelima, D; N' Djin, W A; Souchon, Remi; Rivoire, M; Chapelon, J Y, E-mail: jeremy.chenot@inserm.f [Inserm, U556, Lyon, F-69003 (France)

    2010-06-07

    The use of hand-held ultrasound strain imaging for the intra-operative real-time visualization of HIFU (high-intensity focused ultrasound) ablations produced in the liver by a toroidal transducer was investigated. A linear 12 MHz ultrasound imaging probe was used to obtain radiofrequency signals. Using a fast cross-correlation algorithm, strain images were calculated and displayed at 60 frames s{sup -1}, allowing the use of hand-held strain imaging intra-operatively. Fourteen HIFU lesions were produced in four pigs. Intra-operative strain imaging of HIFU ablations in the liver was feasible owing to the high frame rate. The correlation between dimensions measured on gross pathology and dimensions measured on B-mode images and on strain images were R = 0.72 and R = 0.94 respectively. The contrast between ablated and non-ablated tissue was significantly higher (p < 0.05) in the strain images (22 dB) than in the B-mode images (9 dB). Strain images allowed equivalent or improved definition of ablated regions when compared with B-mode images. Real-time intra-operative hand-held strain imaging seems to be a promising complement to conventional B-mode imaging for the guidance of HIFU ablations produced in the liver during an open procedure. These results support that hand-held strain imaging outperforms conventional B-mode ultrasound and could potentially be used for the assessment of thermal therapies.

  12. An Adaptive Geometry Game for Handheld Devices

    Directory of Open Access Journals (Sweden)

    Harri Ketamo

    2003-01-01

    Full Text Available The development of adaptive learning systems is only in the very beginning. In fact, the concept of adaptive learning systems range from different user interfaces to behaviour adaptive systems as well as from the place and time independent systems to terminal independent systems. When approaching the concept of adaptive learning materials, we must first have conceptual models of the behaviour of different learners within digital environments.The aim of this study was to develop a geometry learning game that adapts to user’s behaviour. The learners in this study were six years old Finnish pre-school pupils. The adaptive system was very limited and the observed behaviour was defined as very simple. However, the software developed achieves good learning results among the tested pupils. The study shows that the learning effect is very promising with this kind of handheld platform and simple adaptation system. This study gives good visions of what can be achieved with more complex behaviour adaptive systems in the field of eLearning.

  13. Extensional rheometry with a handheld mobile device

    Science.gov (United States)

    Marshall, Kristin A.; Liedtke, Aleesha M.; Todt, Anika H.; Walker, Travis W.

    2017-06-01

    The on-site characterization of complex fluids is important for a number of academic and industrial applications. Consequently, a need exists to develop portable rheometers that can provide in the field diagnostics and serve as tools for rapid quality assurance. With the advancement of smartphone technology and the widespread global ownership of smart devices, mobile applications are attractive as platforms for rheological characterization. The present work investigates the use of a smartphone device for the extensional characterization of a series of Boger fluids composed of glycerol/water and poly(ethylene oxide), taking advantage of the increasing high-speed video capabilities (currently up to 240 Hz capture rate at 720p) of smartphone cameras. We report a noticeable difference in the characterization of samples with slight variations in polymer concentration and discuss current device limitations. Potential benefits of a handheld extensional rheometer include its use as a point-of-care diagnostic tool, especially in developing communities, as well as a simple and inexpensive tool for assessing product quality in industry.

  14. Remote Arrhythmia Monitoring System Developed

    Science.gov (United States)

    York, David W.; Mackin, Michael A.; Liszka, Kathy J.; Lichter, Michael J.

    2004-01-01

    Telemedicine is taking a step forward with the efforts of team members from the NASA Glenn Research Center, the MetroHealth campus of Case Western University, and the University of Akron. The Arrhythmia Monitoring System is a completed, working test bed developed at Glenn that collects real-time electrocardiogram (ECG) signals from a mobile or homebound patient, combines these signals with global positioning system (GPS) location data, and transmits them to a remote station for display and monitoring. Approximately 300,000 Americans die every year from sudden heart attacks, which are arrhythmia cases. However, not all patients identified at risk for arrhythmias can be monitored continuously because of technological and economical limitations. Such patients, who are at moderate risk of arrhythmias, would benefit from technology that would permit long-term continuous monitoring of electrical cardiac rhythms outside the hospital environment. Embedded Web Technology developed at Glenn to remotely command and collect data from embedded systems using Web technology is the catalyst for this new telemetry system (ref. 1). In the end-to-end system architecture, ECG signals are collected from a patient using an event recorder and are transmitted to a handheld personal digital assistant (PDA) using Bluetooth, a short-range wireless technology. The PDA concurrently tracks the patient's location via a connection to a GPS receiver. A long distance link is established via a standard Internet connection over a 2.5-generation Global System for Mobile Communications/General Packet Radio Service (GSM/GPRS)1 cellular, wireless infrastructure. Then, the digital signal is transmitted to a call center for monitoring by medical professionals.

  15. Developing a compact multiple laser diode combiner with a single fiber stub output for handheld IoT devices

    Science.gov (United States)

    Lee, Minseok; June, Seunghyeok; Kim, Sehwan

    2018-01-01

    Many biomedical applications require an efficient combination and localization of multiple discrete light sources ( e.g., fluorescence and absorbance imaging). We present a compact 6 channel combiner that couples the output of independent solid-state light sources into a single 400-μm-diameter fiber stub for handheld Internet of Things (IoT) devices. We demonstrate average coupling efficiencies > 80% for each of the 6 laser diodes installed into the prototype. The design supports the use of continuous wave and intensity-modulated laser diodes. This fiber-stub-type beam combiner could be used to construct custom multi-wavelength sources for tissue oximeters, microscopes and molecular imaging technologies. In order to validate its suitability, we applied the developed fiber-stub-type beam combiner to a multi-wavelength light source for a handheld IoT device and demonstrated its feasibility for smart healthcare through a tumor-mimicking silicon phantom.

  16. Precise intraoperative location of gastrointestinal bleeding with a hand-held counter. Work in progress

    International Nuclear Information System (INIS)

    Williamson, M.R.; Boyd, C.M.; McGuire, E.L.

    1986-01-01

    The nuclear medicine bleeding scan is frequently insufficient to locate sites of bleeding precisely, in spite of its great sensitivity. A small, hand-held Geiger-Mueller counter, placed directly on exposed intestine in the operating room, enables precise location of the probable bleeding site. In three patients, the technique allowed a minimal amount of intestine to be resected, distinguished between large- and small-intestinal hemorrhage, and eliminated other foci as sites of bleeding.A

  17. A novel paradigm for telemedicine using the personal bio-monitor.

    Science.gov (United States)

    Bhatikar, Sanjay R; Mahajan, Roop L; DeGroff, Curt

    2002-01-01

    The foray of solid-state technology in the medical field has yielded an arsenal of sophisticated healthcare tools. Personal, portable computing power coupled with the information superhighway open up the possibility of sophisticated healthcare management that will impact the medical field just as much. The full synergistic potential of three interwoven technologies: (1) compact electronics, (2) World Wide Web, and (3) Artificial Intelligence is yet to be realized. The system presented in this paper integrates these technologies synergistically, providing a new paradigm for healthcare. Our idea is to deploy internet-enabled, intelligent, handheld personal computers for medical diagnosis. The salient features of the 'Personal Bio-Monitor' we envisage are: (1) Utilization of the peripheral signals of the body which may be acquired non-invasively and with ease, for diagnosis of medical conditions; (2) An Artificial Neural Network (ANN) based approach for diagnosis; (3) Configuration of the diagnostic device as a handheld for personal use; (4) Internet connectivity, following the emerging bluetooth protocol, for prompt conveyance of information to a patient's health care provider via the World Wide Web. The proposal is substantiated with an intelligent handheld device developed by the investigators for pediatric cardiac auscultation. This device performed accurate diagnoses of cardiac abnormalities in pediatrics using an artificial neural network to process heart sounds acquired by a low-frequency microphone and transmitted its diagnosis to a desktop PC via infrared. The idea of the personal biomonitor presented here has the potential to streamline healthcare by optimizing two valuable resources: physicians' time and sophisticated equipment time. We show that the elements of such a system are in place, with our prototype. Our novel contribution is the synergistic integration of compact electronics' technology, artificial neural network methodology and the wireless web

  18. Applicability of a Diffuse Reflectance Infrared Fourier Transform handheld spectrometer to perform in situ analyses on Cultural Heritage materials.

    Science.gov (United States)

    Arrizabalaga, Iker; Gómez-Laserna, Olivia; Aramendia, Julene; Arana, Gorka; Madariaga, Juan Manuel

    2014-08-14

    This work studies the applicability of a Diffuse Reflectance Infrared Fourier Transform handheld device to perform in situ analyses on Cultural Heritage assets. This portable diffuse reflectance spectrometer has been used to characterise and diagnose the conservation state of (a) building materials of the Guevara Palace (15th century, Segura, Basque Country, Spain) and (b) different 19th century wallpapers manufactured by the Santa Isabel factory (Vitoria-Gasteiz, Basque Country, Spain) and by the well known Dufour and Leroy manufacturers (Paris, France), all of them belonging to the Torre de los Varona Castle (Villanañe, Basque Country, Spain). In all cases, in situ measurements were carried out and also a few samples were collected and measured in the laboratory by diffuse reflectance spectroscopy (DRIFT) in order to validate the information obtained by the handheld instrument. In the analyses performed in situ, distortions in the diffuse reflectance spectra can be observed due to the presence of specular reflection, showing the inverted bands caused by the Reststrahlen effect, in particular on those IR bands with the highest absorption coefficients. This paper concludes that the results obtained in situ by a diffuse reflectance handheld device are comparable to those obtained with laboratory diffuse reflectance spectroscopy equipment and proposes a few guidelines to acquire good spectra in the field, minimising the influence caused by the specular reflection. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. COMPARATIVE GEOMETRICAL INVESTIGATIONS OF HAND-HELD SCANNING SYSTEMS

    Directory of Open Access Journals (Sweden)

    T. P. Kersten

    2016-06-01

    Full Text Available An increasing number of hand-held scanning systems by different manufacturers are becoming available on the market. However, their geometrical performance is little-known to many users. Therefore the Laboratory for Photogrammetry & Laser Scanning of the HafenCity University Hamburg has carried out geometrical accuracy tests with the following systems in co-operation with the Bochum University of Applied Sciences (Laboratory for Photogrammetry as well as the Humboldt University in Berlin (Institute for Computer Science: DOTProduct DPI-7, Artec Spider, Mantis Vision F5 SR, Kinect v1 + v2, Structure Sensor and Google’s Project Tango. In the framework of these comparative investigations geometrically stable reference bodies were used. The appropriate reference data were acquired by measurement with two structured light projection systems (AICON smartSCAN and GOM ATOS I 2M. The comprehensive test results of the different test scenarios are presented and critically discussed in this contribution.

  20. Hand-held optical fuel pin scanner

    International Nuclear Information System (INIS)

    Kirchner, T.L.; Powers, H.G.

    1987-01-01

    A portable, hand-held apparatus is described for optically scanning indicia imprinted about a planar end face of an article having an outer wall surface, the apparatus comprising: a supporting frame; light detector means fixed to the frame for digitizing light patterns directed thereto; indexing means on the frame for engaging the planar end face and locating the end face in a preselected focal plane on the frame. The indexing means has an inner wall surface complementary to the article wall surface for disposition thereabout and terminates in an end portion beyond the planar end face. The inner wall surface has a radially inwardly extending shoulder spaced from the end portion and engageable with the planar end face; light means directed onto the preselected focal plane; optical means mounted on the frame about a central axis, the optical means being optically interposed between the indexing means and the light detector means for directing reflected light from the preselected focal plane to the light detector means and including a dove prism centrally aligned along the central axis; and means for selectively rotating the dove prism relative to the frame about the central axis to thereby rotate the image from the focal plane as transmitted to the light detector means

  1. Hip- and knee-strength assessments using a hand-held dynamometer with external belt-fixation are inter-tester reliable

    DEFF Research Database (Denmark)

    Thorborg, Kristian; Bandholm, Thomas; Hölmich, Per

    2013-01-01

    PURPOSE: In football, ice-hockey, and track and field, injuries have been predicted, and hip- and knee-strength deficits quantified using hand-held dynamometry (HHD). However, systematic bias exists when testers of different sex and strength perform the measurements. Belt-fixation of the dynamome...

  2. Suitability of capillary blood obtained by a minimally invasive lancet technique to detect subclinical ketosis in dairy cows by using 3 different electronic hand-held devices.

    Science.gov (United States)

    Kanz, P; Drillich, M; Klein-Jöbstl, D; Mair, B; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2015-09-01

    for the specific hand-held meters, no significant differences between the devices in Se and Sp to detect subclinical ketosis in coccygeal blood were observed. Calculated test characteristics for analyzing capillary blood using the hand-held devices were numerically smaller compared with blood obtained from a coccygeal vessel, but overlapping confidence intervals indicate no statistical difference between the origin of the sample. Hence, this procedure seems to be suitable for ketosis monitoring in dairy cows, but further validation with more data from different farms is recommended. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  3. Visual Search and Target Cueing: A Comparison of Head-Mounted Versus Hand-Held Displays on the Allocation of Visual Attention

    National Research Council Canada - National Science Library

    Yeh, Michelle; Wickens, Christopher D

    1998-01-01

    We conducted a study to examine the effects of target cueing and conformality with a hand-held or head-mounted display to determine their effects on visual search tasks requiring focused and divided attention...

  4. Handheld and automated ultrasonic spray deposition of conductive PEDOT:PSS films and their application in AC EL devices

    NARCIS (Netherlands)

    Ely, Fernando; Matsumoto, Agatha; Zoetebier, Bram; Peressinotto, Valdirene S.; Hirata, Marcelo Kioshi; de Sousa, Douglas A.; Maciel, Rubens

    2014-01-01

    In this contribution we explore the spray deposition technique to achieve smooth films based on the conductive polymer PEDOT:PSS. Two different spray systems were used and compared namely: (a) handheld airbrush and (b) automated ultrasonic spray system. For each system a number of parameters were

  5. Performance Investigation of a Handheld 3d Scanner to Define Good Practices for Small Artefact 3d Modeling

    Science.gov (United States)

    Lachat, E.; Landes, T.; Grussenmeyer, P.

    2017-08-01

    Handheld 3D scanners can be used to complete large scale models with the acquisition of occluded areas or small artefacts. This may be of interest for digitization projects in the field of Cultural Heritage, where detailed areas may require a specific treatment. Such sensors present the advantage of being easily portable in the field, and easily usable even without particular knowledge. In this paper, the Freestyle3D handheld scanner launched on the market in 2015 by FARO is investigated. Different experiments are described, covering various topics such as the influence of range or color on the measurements, but also the precision achieved for geometrical primitive digitization. These laboratory experiments are completed by acquisitions performed on engraved and sculpted stone blocks. This practical case study is useful to investigate which acquisition protocol seems to be the more adapted and leads to precise results. The produced point clouds will be compared to photogrammetric surveys for the purpose of their accuracy assessment.

  6. Linear Text vs. Non-Linear Hypertext in Handheld Computers: Effects on Declarative and Structural Knowledge, and Learner Motivation

    Science.gov (United States)

    Son, Chanhee; Park, Sanghoon; Kim, Minjeong

    2011-01-01

    This study compared linear text-based and non-linear hypertext-based instruction in a handheld computer regarding effects on two different levels of knowledge (declarative and structural knowledge) and learner motivation. Forty four participants were randomly assigned to one of three experimental conditions: linear text, hierarchical hypertext,…

  7. Do adjunctive flap-monitoring technologies impact clinical decision making? An analysis of microsurgeon preferences and behavior by body region.

    Science.gov (United States)

    Bellamy, Justin L; Mundinger, Gerhard S; Flores, José M; Wimmers, Eric G; Yalanis, Georgia C; Rodriguez, Eduardo D; Sacks, Justin M

    2015-03-01

    Multiple perfusion assessment technologies exist to identify compromised microvascular free flaps. The effectiveness, operability, and cost of each technology vary. The authors investigated surgeon preference and clinical behavior with several perfusion assessment technologies. A questionnaire was sent to members of the American Society for Reconstructive Microsurgery concerning perceptions and frequency of use of several technologies in varied clinical situations. Demographic information was also collected. Adjusted odds ratios were calculated using multinomial logistic regression accounting for clustering of similar practices within institutions/regions. The questionnaire was completed by 157 of 389 participants (40.4 percent response rate). Handheld Doppler was the most commonly preferred free flap-monitoring technology (56.1 percent), followed by implantable Doppler (22.9 percent) and cutaneous tissue oximetry (16.6 percent). Surgeons were significantly more likely to opt for immediate take-back to the operating room when presented with a concerning tissue oximetry readout compared with a concerning handheld Doppler signal (OR, 2.82; p decision making did not significantly differ by demographics, training, or practice setup. Although most surgeons still prefer to use standard handheld Doppler for free flap assessment, respondents were significantly more likely to opt for immediate return to the operating room for a concerning tissue oximetry reading than an abnormal Doppler signal. This suggests that tissue oximetry may have the greatest impact on clinical decision making in the postoperative period.

  8. Estimating the accuracy of optic nerve sheath diameter measurement using a pocket-sized, handheld ultrasound on a simulation model.

    Science.gov (United States)

    Johnson, Garrett G R J; Zeiler, Frederick A; Unger, Bertram; Hansen, Gregory; Karakitsos, Dimitrios; Gillman, Lawrence M

    2016-12-01

    Ultrasound measurement of optic nerve sheath diameter (ONSD) appears to be a promising, rapid, non-invasive bedside tool for identification of elevated intra-cranial pressure. With improvements in ultrasound technology, machines are becoming smaller; however, it is unclear if these ultra-portable handheld units have the resolution to make these measurements precisely. In this study, we estimate the accuracy of ONSD measurement in a pocket-sized ultrasound unit. Utilizing a locally developed, previously validated model of the eye, ONSD was measured by two expert observers, three times with two machines and on five models with different optic nerve sheath sizes. A pocket ultrasound (Vscan, GE Healthcare) and a standard portable ultrasound (M-Turbo, SonoSite) were used to measure the models. Data was analyzed by Bland-Altman plot and intra-class correlation coefficient (ICC). The ICC between raters for the SonoSite was 0.878, and for the Vscan was 0.826. The between-machine agreement ICC was 0.752. Bland-Altman agreement analysis between the two ultrasound methods showed an even spread across the range of sheath sizes, and that the Vscan tended to read on average 0.33 mm higher than the SonoSite for each measurement, with a standard deviation of 0.65 mm. Accurate ONSD measurement may be possible utilizing pocket-sized, handheld ultrasound devices despite their small screen size, lower resolution, and lower probe frequencies. Further study in human subjects is warranted for all newer handheld ultrasound models as they become available on the market.

  9. Influence of Fine Motor Skill on Accuracy of Measurements Using a Handheld Sliding Caliper at Adolescents Group Aged 19-20

    Science.gov (United States)

    Brychta, Petr; Hojk, Vladimír; Hrubý, Jiří; Pilc, Jozef

    2017-10-01

    This innovate ve interdisciplinary study deals with influence of fine motor skill level (finger dexterity) of individual on his measurement results in metrology practice. The main objective of this study was determinate fine motor skill level of individuals using a motor test. Further determinate the potential effect of different fine motor skill levels on accuracy of measuring using a mechanical handheld sliding caliper. Fine motor skill test and metrological test were implemented. Pursuant the results of fine motor skill test were probands divided into 2 groups. The groups are significantly different on accuracy of measurement (p=0,006). Pearson coefficient shows a significant correlation r = - 0.66 between the Purdue Pegboard test and a measurement error. Results confirmed that the fine motor skill of the upper limbs (especially finger coordination) significantly influence accuracy of measurement using a mechanical handheld sliding caliper.

  10. Criticality Safety Support to a Project Addressing SNM Legacy Items at LLNL

    International Nuclear Information System (INIS)

    Pearson, J S; Burch, J G; Dodson, K E; Huang, S T

    2005-01-01

    and new ES and H container labels applied. In many cases, legacy material that was inspected was determined to be excess to programmatic needs and it was then either processed to meet the DOE-3013-STD or designated as TRU waste and disposed of accordingly. During FY2003 through FY2004 approximately 1600 items were opened and the items processed if necessary, repackaged and newly labeled with ES and H labels. As of April, 2005, there are only 32 non-ES and H labeled items in existence within the Plutonium Facility. Due to a consolidated effort in dealing with the legacy items, the problems associated with storage of these items at LLNL has been substantially abated. The paper will discuss the background, implementation, and results of the SNM Legacy Items Implementation Project. Benefits and Lessons Learned will be identified

  11. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites

  12. Position-sensitive radiation monitoring (surface contamination monitor). Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    1999-06-01

    The Shonka Research Associates, Inc. Position-Sensitive Radiation Monitor both detects surface radiation and prepares electronic survey map/survey report of surveyed area automatically. The electronically recorded map can be downloaded to a personal computer for review and a map/report can be generated for inclusion in work packages. Switching from beta-gamma detection to alpha detection is relatively simple and entails moving a switch position to alpha and adjusting the voltage level to an alpha detection level. No field calibration is required when switching from beta-gamma to alpha detection. The system can be used for free-release surveys because it meets the federal detection level sensitivity limits requires for surface survey instrumentation. This technology is superior to traditionally-used floor contamination monitor (FCM) and hand-held survey instrumentation because it can precisely register locations of radioactivity and accurately correlate contamination levels to specific locations. Additionally, it can collect and store continuous radiological data in database format, which can be used to produce real-time imagery as well as automated graphics of survey data. Its flexible design can accommodate a variety of detectors. The cost of the innovative technology is 13% to 57% lower than traditional methods. This technology is suited for radiological surveys of flat surfaces at US Department of Energy (DOE) nuclear facility decontamination and decommissioning (D and D) sites or similar public or commercial sites.

  13. Comparison of low-cost handheld retinal camera and traditional table top retinal camera in the detection of retinal features indicating a risk of cardiovascular disease

    Science.gov (United States)

    Joshi, V.; Wigdahl, J.; Nemeth, S.; Zamora, G.; Ebrahim, E.; Soliz, P.

    2018-02-01

    Retinal abnormalities associated with hypertensive retinopathy are useful in assessing the risk of cardiovascular disease, heart failure, and stroke. Assessing these risks as part of primary care can lead to a decrease in the incidence of cardiovascular disease-related deaths. Primary care is a resource limited setting where low cost retinal cameras may bring needed help without compromising care. We compared a low-cost handheld retinal camera to a traditional table top retinal camera on their optical characteristics and performance to detect hypertensive retinopathy. A retrospective dataset of N=40 subjects (28 with hypertensive retinopathy, 12 controls) was used from a clinical study conducted at a primary care clinic in Texas. Non-mydriatic retinal fundus images were acquired using a Pictor Plus hand held camera (Volk Optical Inc.) and a Canon CR1-Mark II tabletop camera (Canon USA) during the same encounter. The images from each camera were graded by a licensed optometrist according to the universally accepted Keith-Wagener-Barker Hypertensive Retinopathy Classification System, three weeks apart to minimize memory bias. The sensitivity of the hand-held camera to detect any level of hypertensive retinopathy was 86% compared to the Canon. Insufficient photographer's skills produced 70% of the false negative cases. The other 30% were due to the handheld camera's insufficient spatial resolution to resolve the vascular changes such as minor A/V nicking and copper wiring, but these were associated with non-referable disease. Physician evaluation of the performance of the handheld camera indicates it is sufficient to provide high risk patients with adequate follow up and management.

  14. Beyond mere information provisioning: a handheld museum guide based on social activities and playful learning

    OpenAIRE

    SCHROYEN, Jolien; GABRIELS, Kris; TEUNKENS, Daniel; ROBERT, Karel; LUYTEN, Kris; CONINX, Karin

    2007-01-01

    During a museum visit, social interaction can improve intellectual, social, personal and cultural development. With the advances in technology, the use of personal mobile handheld devices – such as Personal Digital Assistants (PDAs) – that replace the traditional paper guidebooks is becoming a common sight at various heritage sites all over the world. This technology often leads to problems such as isolating visitors from their companions and distracting visitors away from their surroundings....

  15. First demonstration of real-time gamma imaging by using a handheld Compton camera for particle therapy

    Energy Technology Data Exchange (ETDEWEB)

    Taya, T., E-mail: taka48138@ruri.waseda.jp [Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555 (Japan); Kataoka, J.; Kishimoto, A.; Iwamoto, Y.; Koide, A. [Research Institute for Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku, Tokyo 169-8555 (Japan); Nishio, T. [Graduate School of Biomedical and Health Science, Hiroshima University, 1-2-3, Kasumi, Minami-ku, Hiroshima-shi, Hiroshima (Japan); Kabuki, S. [School of Medicine, Tokai University, 143 Shimokasuya, Isehara-shi, Kanagawa (Japan); Inaniwa, T. [National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba-shi, Chiba (Japan)

    2016-09-21

    The use of real-time gamma imaging for cancer treatment in particle therapy is expected to improve the accuracy of the treatment beam delivery. In this study, we demonstrated the imaging of gamma rays generated by the nuclear interactions during proton irradiation, using a handheld Compton camera (14 cm×15 cm×16 cm, 2.5 kg) based on scintillation detectors. The angular resolution of this Compton camera is ∼8° at full width at half maximum (FWHM) for a {sup 137}Cs source. We measured the energy spectra of the gamma rays using a LaBr{sub 3}(Ce) scintillator and photomultiplier tube, and using the handheld Compton camera, performed image reconstruction when using a 70 MeV proton beam to irradiate a water, Ca(OH){sub 2}, and polymethyl methacrylate (PMMA) phantom. In the energy spectra of all three phantoms, we found an obvious peak at 511 keV, which was derived from annihilation gamma rays, and in the energy spectrum of the PMMA phantom, we found another peak at 718 keV, which contains some of the prompt gamma rays produced from {sup 10}B. Therefore, we evaluated the peak positions of the projection from the reconstructed images of the PMMA phantom. The differences between the peak positions and the Bragg peak position calculated using simulation are 7 mm±2 mm and 3 mm±8 mm, respectively. Although we could quickly acquire online gamma imaging of both of the energy ranges during proton irradiation, we cannot arrive at a clear conclusion that prompt gamma rays sufficiently trace the Bragg peak from these results because of the uncertainty given by the spatial resolution of the Compton camera. We will develop a high-resolution Compton camera in the near future for further study. - Highlights: • Gamma imaging during proton irradiation by a handheld Compton camera is demonstrated. • We were able to acquire the online gamma-ray images quickly. • We are developing a high resolution Compton camera for range verification.

  16. Using two detectors concurrently to monitor ambient dose equivalent rates in vehicle surveys of radiocesium contaminated land.

    Science.gov (United States)

    Takeishi, Minoru; Shibamichi, Masaru; Malins, Alex; Kurikami, Hiroshi; Murakami, Mitsuhiro; Saegusa, Jun; Yoneya, Masayuki

    2017-10-01

    In response to the accident at Tokyo Electric Power Company's Fukushima Dai-ichi Nuclear Power Plant (FDNPP), vehicle-borne monitoring was used to map radiation levels for radiological protection of the public. By convention measurements from vehicle-borne surveys are converted to the ambient dose equivalent rate at 1 m height in the absence of the vehicle. This allows for comparison with results from other types of survey, including surveys with hand-held or airborne instruments. To improve the accuracy of the converted results from vehicle-borne surveys, we investigated combining measurements from two detectors mounted on the vehicle at different heights above the ground. A dual-detector setup was added to a JAEA monitoring car and compared against hand-held survey meter measurements in Fukushima Prefecture. The results obtained by combining measurements from two detectors were within ±20% of the hand-held reference measurements. The mean absolute percentage deviation from the reference measurements was 7.2%. The combined results from the two detectors were more accurate than those from either the roof-mounted detector, or the detector inside the vehicle, taken alone. One issue with vehicle-borne surveys is that ambient dose equivalent rates above roads are not necessarily representative of adjacent areas. This is because radiocesium is often deficient on asphalt surfaces, as it is easily scrubbed off by rain, wind and vehicle tires. To tackle this issue, we investigated mounting heights for vehicle-borne detectors using Monte Carlo gamma-ray simulations. When radiocesium is deficient on a road compared to the adjacent land, mounting detectors high on vehicles yields results closer to the values adjacent to the road. The ratio of ambient dose equivalent rates reported by detectors mounted at different heights in a dual-detector setup indicates whether radiocesium is deficient on the road compared to the adjacent land. Copyright © 2017 Elsevier Ltd. All rights

  17. An integrated portable hand-held analyser for real-time isothermal nucleic acid amplification

    International Nuclear Information System (INIS)

    Smith, Matthew C.; Steimle, George; Ivanov, Stan; Holly, Mark; Fries, David P.

    2007-01-01

    A compact hand-held heated fluorometric instrument for performing real-time isothermal nucleic acid amplification and detection is described. The optoelectronic instrument combines a Printed Circuit Board/Micro Electro Mechanical Systems (PCB/MEMS) reaction detection/chamber containing an integrated resistive heater with attached miniature LED light source and photo-detector and a disposable glass waveguide capillary to enable a mini-fluorometer. The fluorometer is fabricated and assembled in planar geometry, rolled into a tubular format and packaged with custom control electronics to form the hand-held reactor. Positive or negative results for each reaction are displayed to the user using an LED interface. Reaction data is stored in FLASH memory for retrieval via an in-built USB connection. Operating on one disposable 3 V lithium battery >12, 60 min reactions can be performed. Maximum dimensions of the system are 150 mm (h) x 48 mm (d) x 40 mm (w), the total instrument weight (with battery) is 140 g. The system produces comparable results to laboratory instrumentation when performing a real-time nucleic acid sequence-based amplification (NASBA) reaction, and also displayed comparable precision, accuracy and resolution to laboratory-based real-time nucleic acid amplification instrumentation. A good linear response (R 2 = 0.948) to fluorescein gradients ranging from 0.5 to 10 μM was also obtained from the instrument indicating that it may be utilized for other fluorometric assays. This instrument enables an inexpensive, compact approach to in-field genetic screening, providing results comparable to laboratory equipment with rapid user feedback as to the status of the reaction

  18. An integrated portable hand-held analyser for real-time isothermal nucleic acid amplification

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Matthew C. [College of Marine Science, University of South Florida, St Petersburg, FL (United States)], E-mail: msmith@marine.usf.edu; Steimle, George; Ivanov, Stan; Holly, Mark; Fries, David P. [College of Marine Science, University of South Florida, St Petersburg, FL (United States)

    2007-08-29

    A compact hand-held heated fluorometric instrument for performing real-time isothermal nucleic acid amplification and detection is described. The optoelectronic instrument combines a Printed Circuit Board/Micro Electro Mechanical Systems (PCB/MEMS) reaction detection/chamber containing an integrated resistive heater with attached miniature LED light source and photo-detector and a disposable glass waveguide capillary to enable a mini-fluorometer. The fluorometer is fabricated and assembled in planar geometry, rolled into a tubular format and packaged with custom control electronics to form the hand-held reactor. Positive or negative results for each reaction are displayed to the user using an LED interface. Reaction data is stored in FLASH memory for retrieval via an in-built USB connection. Operating on one disposable 3 V lithium battery >12, 60 min reactions can be performed. Maximum dimensions of the system are 150 mm (h) x 48 mm (d) x 40 mm (w), the total instrument weight (with battery) is 140 g. The system produces comparable results to laboratory instrumentation when performing a real-time nucleic acid sequence-based amplification (NASBA) reaction, and also displayed comparable precision, accuracy and resolution to laboratory-based real-time nucleic acid amplification instrumentation. A good linear response (R{sup 2} = 0.948) to fluorescein gradients ranging from 0.5 to 10 {mu}M was also obtained from the instrument indicating that it may be utilized for other fluorometric assays. This instrument enables an inexpensive, compact approach to in-field genetic screening, providing results comparable to laboratory equipment with rapid user feedback as to the status of the reaction.

  19. Object localization in handheld thermal images for fireground understanding

    Science.gov (United States)

    Vandecasteele, Florian; Merci, Bart; Jalalvand, Azarakhsh; Verstockt, Steven

    2017-05-01

    Despite the broad application of the handheld thermal imaging cameras in firefighting, its usage is mostly limited to subjective interpretation by the person carrying the device. As remedies to overcome this limitation, object localization and classification mechanisms could assist the fireground understanding and help with the automated localization, characterization and spatio-temporal (spreading) analysis of the fire. An automated understanding of thermal images can enrich the conventional knowledge-based firefighting techniques by providing the information from the data and sensing-driven approaches. In this work, transfer learning is applied on multi-labeling convolutional neural network architectures for object localization and recognition in monocular visual, infrared and multispectral dynamic images. Furthermore, the possibility of analyzing fire scene images is studied and their current limitations are discussed. Finally, the understanding of the room configuration (i.e., objects location) for indoor localization in reduced visibility environments and the linking with Building Information Models (BIM) are investigated.

  20. Active neutron technique for detecting attempted special nuclear material diversion

    International Nuclear Information System (INIS)

    Smith, G.W.; Rice, L.G. III.

    1979-01-01

    The identification of special nuclear material (SNM) diversion is necessary if SNM inventory control is to be maintained at nuclear facilities. (Special nuclear materials are defined for this purpose as either 235 U of 239 Pu.) Direct SNM identification by the detection of natural decay or fission radiation is inadequate if the SNM is concealed by appropriate shielding. The active neutron interrogation technique described combines direct SNM identification by delayed fission neutron (DFN) detection with implied SNM detection by the identification of materials capable of shielding SNM from direct detection. This technique is being developed for application in an unattended material/equipment portal through which items such as electronic instruments, packages, tool boxes, etc., will pass. The volume of this portal will be 41-cm wide, 53-cm high and 76-cm deep. The objective of this technique is to identify an attempted diversion of at least 20 grams of SNM with a measurement time of 30 seconds

  1. 3D handheld endoscope for optical coherence tomography of the human oral mucosa in vivo

    Science.gov (United States)

    Walther, Julia; Schnabel, Christian; Ebert, Nadja; Baumann, Michael; Koch, Edmund

    2017-07-01

    The early non-invasive diagnosis of epithelial tissue alterations in daily clinical routine is still challenging. Since optical coherence tomography (OCT) shows the potential to differentiate between benign and malignant tissue of primal endothelium, OCT could be beneficial for the early diagnosis of malignancies in routine health checks. In this research, a new handheld endoscopic scanning unit was designed and connected to a spectral domain OCT system of our workgroup for the in vivo imaging of the human oral mucosa.

  2. Towards Robust Self-Calibration for Handheld 3d Line Laser Scanning

    Science.gov (United States)

    Bleier, M.; Nüchter, A.

    2017-11-01

    This paper studies self-calibration of a structured light system, which reconstructs 3D information using video from a static consumer camera and a handheld cross line laser projector. Intersections between the individual laser curves and geometric constraints on the relative position of the laser planes are exploited to achieve dense 3D reconstruction. This is possible without any prior knowledge of the movement of the projector. However, inaccurrately extracted laser lines introduce noise in the detected intersection positions and therefore distort the reconstruction result. Furthermore, when scanning objects with specular reflections, such as glossy painted or metalic surfaces, the reflections are often extracted from the camera image as erroneous laser curves. In this paper we investiagte how robust estimates of the parameters of the laser planes can be obtained despite of noisy detections.

  3. Implementation of synthetic aperture imaging on a hand-held device

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Kjeldsen, Thomas; Larsen, Lee

    2014-01-01

    -held devices all with different chipsets and a BK Medical UltraView 800 ultrasound scanner emulating a wireless probe. The wireless transmission is benchmarked using an imaging setup consisting of 269 scan lines x 1472 complex samples (1.58 MB pr. frame, 16 frames per second). The measured data throughput...... reached an average of 28.8 MB/s using a LG G2 mobile device, which is more than the required data throughput of 25.3 MB/s. Benchmarking the processing performance for B-mode imaging showed a total processing time of 18.9 ms (53 frames/s), which is less than the acquisition time (62.5 ms).......This paper presents several implementations of Syn- thetic Aperture Sequential Beamforming (SASB) on commer- cially available hand-held devices. The implementations include real-time wireless reception of ultrasound radio frequency sig- nals and GPU processing for B-mode imaging. The proposed...

  4. Comparison of maximal voluntary isometric contraction and hand-held dynamometry in measuring muscle strength of patients with progressive lower motor neuron syndrome

    NARCIS (Netherlands)

    Visser, J.; Mans, E.; de Visser, M.; van den Berg-Vos, R. M.; Franssen, H.; de Jong, J. M. B. V.; van den Berg, L. H.; Wokke, J. H. J.; de Haan, R. J.

    2003-01-01

    Context. Maximal voluntary isometric contraction, a method quantitatively assessing muscle strength, has proven to be reliable, accurate and sensitive in amyotrophic lateral sclerosis. Hand-held dynamometry is less expensive and more quickly applicable than maximal voluntary isometric contraction.

  5. Handheld Devices and Video Modeling to Enhance the Learning of Self-Help Skills in Adolescents With Autism Spectrum Disorder.

    Science.gov (United States)

    Campbell, Joseph E; Morgan, Michele; Barnett, Veronica; Spreat, Scott

    2015-04-01

    The viewing of videos is a much-studied intervention to teach self-help, social, and vocational skills. Many of the studies to date looked at video modeling using televisions, computers, and other large screens. This study looked at the use of video modeling on portable handheld devices to teach hand washing to three adolescent students with an autism spectrum disorder. Three students participated in this 4-week study conducted by occupational therapists. Baseline data were obtained for the first student for 1 week, the second for 2 weeks, and the third for 3 weeks; videos were introduced when the participants each finished the baseline phase. Given the cognitive and motor needs of the participants, the occupational therapist set the player so that the participants only had to press the play button to start the video playing. The participants were able to hold the players and view at distances that were most appropriate for their individual needs and preferences. The results suggest that video modeling on a handheld device improves the acquisition of self-help skills.

  6. A New Algorithm for Radioisotope Identification of Shielded and Masked SNM/RDD Materials

    International Nuclear Information System (INIS)

    Jeffcoat, R.

    2012-01-01

    Detection and identification of shielded and masked nuclear materials is crucial to national security, but vast borders and high volumes of traffic impose stringent requirements for practical detection systems. Such tools must be be mobile, and hence low power, provide a low false alarm rate, and be sufficiently robust to be operable by non-technical personnel. Currently fielded systems have not achieved all of these requirements simultaneously. Transport modeling such as that done in GADRAS is able to predict observed spectra to a high degree of fidelity; our research is focusing on a radionuclide identification algorithm that inverts this modeling within the constraints imposed by a handheld device. Key components of this work include incorporation of uncertainty as a function of both the background radiation estimate and the hypothesized sources, dimensionality reduction, and nonnegative matrix factorization. We have partially evaluated performance of our algorithm on a third-party data collection made with two different sodium iodide detection devices. Initial results indicate, with caveats, that our algorithm performs as good as or better than the on-board identification algorithms. The system developed was based on a probabilistic approach with an improved approach to variance modeling relative to past work. This system was chosen based on technical innovation and system performance over algorithms developed at two competing research institutions. One key outcome of this probabilistic approach was the development of an intuitive measure of confidence which was indeed useful enough that a classification algorithm was developed based around alarming on high confidence targets. This paper will present and discuss results of this novel approach to accurately identifying shielded or masked radioisotopes with radiation detection systems.

  7. The Pixel Paradox and Transition-Metal Spectroscopy: One of Many Uses of the Handheld Digital Microscope in Chemical Demonstrations

    Science.gov (United States)

    Vitz, Ed

    2010-01-01

    A handheld digital microscope (HDM) interfaced to a computer with a presentation projector is used to project an out-of-focus yellow patch on the screen, then the patch is brought into focus to show that, paradoxically, there are red and green but no yellow pixels. Chromaticity diagrams are used to discuss this observation and spectroscopic…

  8. Handheld magnetic probe with permanent magnet and Hall sensor for identifying sentinel lymph nodes in breast cancer patients.

    Science.gov (United States)

    Sekino, Masaki; Kuwahata, Akihiro; Ookubo, Tetsu; Shiozawa, Mikio; Ohashi, Kaichi; Kaneko, Miki; Saito, Itsuro; Inoue, Yusuke; Ohsaki, Hiroyuki; Takei, Hiroyuki; Kusakabe, Moriaki

    2018-01-19

    The newly developed radioisotope-free technique based on magnetic nanoparticle detection using a magnetic probe is a promising method for sentinel lymph node biopsy. In this study, a novel handheld magnetic probe with a permanent magnet and magnetic sensor is developed to detect the sentinel lymph nodes in breast cancer patients. An outstanding feature of the probe is the precise positioning of the sensor at the magnetic null point of the magnet, leading to highly sensitive measurements unaffected by the strong ambient magnetic fields of the magnet. Numerical and experimental results show that the longitudinal detection length is approximately 10 mm, for 140 μg of iron. Clinical tests were performed, for the first time, using magnetic and blue dye tracers-without radioisotopes-in breast cancer patients to demonstrate the performance of the probe. The nodes were identified through transcutaneous and ex-vivo measurements, and the iron accumulation in the nodes was quantitatively revealed. These results show that the handheld magnetic probe is useful in sentinel lymph node biopsy and that magnetic techniques are widely being accepted as future standard methods in medical institutions lacking nuclear medicine facilities.

  9. Handheld optical coherence tomography-reflectance confocal microscopy probe for detection of basal cell carcinoma and delineation of margins

    Science.gov (United States)

    Iftimia, Nicusor; Yélamos, Oriol; Chen, Chih-Shan J.; Maguluri, Gopi; Cordova, Miguel A.; Sahu, Aditi; Park, Jesung; Fox, William; Alessi-Fox, Christi; Rajadhyaksha, Milind

    2017-07-01

    We present a hand-held implementation and preliminary evaluation of a combined optical coherence tomography (OCT) and reflectance confocal microscopy (RCM) probe for detecting and delineating the margins of basal cell carcinomas (BCCs) in human skin in vivo. A standard OCT approach (spectrometer-based) with a central wavelength of 1310 nm and 0.11 numerical aperture (NA) was combined with a standard RCM approach (830-nm wavelength and 0.9 NA) into a common path hand-held probe. Cross-sectional OCT images and enface RCM images are simultaneously displayed, allowing for three-dimensional microscopic assessment of tumor morphology in real time. Depending on the subtype and depth of the BCC tumor and surrounding skin conditions, OCT and RCM imaging are able to complement each other, the strengths of each helping overcome the limitations of the other. Four representative cases are summarized, out of the 15 investigated in a preliminary pilot study, demonstrating how OCT and RCM imaging may be synergistically combined to more accurately detect BCCs and more completely delineate margins. Our preliminary results highlight the potential benefits of combining the two technologies within a single probe to potentially guide diagnosis as well as treatment of BCCs.

  10. Report on the 31st annual meeting of the Society of Nuclear Medicine (SNM), June 4-8, 1984, Los Angeles, USA

    International Nuclear Information System (INIS)

    Pfannenstiel, P.

    1984-01-01

    As the meeting of the Society of Nuclear Medicine ''SNM '84'' in Los Angeles made clear, the future of nuclear medicine lies in regional functional diagnostics in vivo, and biochemistry will in future play a dominating past in nuclear medicine, the more since all life is based on biochemical process which it is not so far possible to investigate in vivo except by means of nuclear medicine. The hopes for wider PET uses seem unrealistic. But at the PET principle is increasingly being transterred to SPECT - 'not looking for cold spots, but for function' - nuclear medicine will perhaps gain a new independent significance and nuclear medicine is badly in need of a new upswing. To achieve this goal it must emerge from its (self-inflicted) isolation and seek interdisciplinary cooperation again. For other fields can learn from nuclear medicine, and nuclear medicine can learn a lot from other fields. Following quite an impetuous development at the beginning of the 70s, nuclear medicine has now entered its 'period of maturity'. It is characterized by perfect apparatuses and a wide range of differentiated substances for radiodiagnosis offering many new possibilities of examination. The new methods are by no means 'mature' yet. If the position of nuclear medicine as a young diagnostical discipline is to be strengthened it must be repared to jettison methods that have become obsolete or for which alternative processes have been found and break interesting new ground. (orig./MG) [de

  11. Handheld real-time volumetric 3-D gamma-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Haefner, Andrew, E-mail: ahaefner@lbl.gov [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Barnowski, Ross [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Luke, Paul; Amman, Mark [Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States); Vetter, Kai [Department of Nuclear Engineering, UC Berkeley, 4155 Etcheverry Hall, MC 1730, Berkeley, CA 94720 (United States); Lawrence Berkeley National Lab – Applied Nuclear Physics, 1 Cyclotron Road, Berkeley, CA 94720 (United States)

    2017-06-11

    This paper presents the concept of real-time fusion of gamma-ray imaging and visual scene data for a hand-held mobile Compton imaging system in 3-D. The ability to obtain and integrate both gamma-ray and scene data from a mobile platform enables improved capabilities in the localization and mapping of radioactive materials. This not only enhances the ability to localize these materials, but it also provides important contextual information of the scene which once acquired can be reviewed and further analyzed subsequently. To demonstrate these concepts, the high-efficiency multimode imager (HEMI) is used in a hand-portable implementation in combination with a Microsoft Kinect sensor. This sensor, in conjunction with open-source software, provides the ability to create a 3-D model of the scene and to track the position and orientation of HEMI in real-time. By combining the gamma-ray data and visual data, accurate 3-D maps of gamma-ray sources are produced in real-time. This approach is extended to map the location of radioactive materials within objects with unknown geometry.

  12. Portable Hand-Held Electrochemical Sensor for the Transuranics

    Energy Technology Data Exchange (ETDEWEB)

    Dale D. Russell, William B. Knowlton, Ph.D.; Russel Hertzog, Ph.D

    2005-11-25

    sensitive detector for uranium. Millimeter scale electrodes, operated by a hand-held instrument assembled in this lab and operated in the voltammetric mode, were transported to the DOE-Nevada test site (Las Vegas, NV) where field detection and quantitation of plutonium, uranium, and a mixture of these two elements was also demonstrated. Several probe designs were prepared, built and tested including probes with movable protective windows. A miniature, battery powered potentiostat was designed, built and demonstrated for use in a hand-held field portable instrument. This work was performed largely by undergraduates who gained valuable research experience, and many of them have continued on to graduate schools. In addition, they all gained exposure to and appreciation for national security research, in particular non-proliferation research. Four graduate students participated and one earned the MS degree on this project.

  13. Standard echocardiography versus handheld echocardiography for the detection of subclinical rheumatic heart disease: protocol for a systematic review.

    Science.gov (United States)

    Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Zühlke, Liesl J; Engel, Mark E

    2018-02-10

    Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this

  14. User-friendly tools on handheld devices for observer performance study

    Science.gov (United States)

    Matsumoto, Takuya; Hara, Takeshi; Shiraishi, Junji; Fukuoka, Daisuke; Abe, Hiroyuki; Matsusako, Masaki; Yamada, Akira; Zhou, Xiangrong; Fujita, Hiroshi

    2012-02-01

    ROC studies require complex procedures to select cases from many data samples, and to set confidence levels in each selected case to generate ROC curves. In some observer performance studies, researchers have to develop software with specific graphical user interface (GUI) to obtain confidence levels from readers. Because ROC studies could be designed for various clinical situations, it is difficult task for preparing software corresponding to every ROC studies. In this work, we have developed software for recording confidence levels during observer studies on tiny personal handheld devices such as iPhone, iPod touch, and iPad. To confirm the functions of our software, three radiologists performed observer studies to detect lung nodules by using public database of chest radiograms published by Japan Society of Radiological Technology. The output in text format conformed to the format for the famous ROC kit from the University of Chicago. Times required for the reading each case was recorded very precisely.

  15. Internal transfers of special nuclear material - March 1975

    International Nuclear Information System (INIS)

    Anon.

    1976-01-01

    Paragraph 70.51(e) of 10 CFR Part 70 requires, with certain exceptions stated in the rule, that each licensee authorized to possess more than one effective kilogram of special nuclear material (SNM) maintain certain procedures. These procedures are to include: (1) records of the quantities of SNM added to or removed from the process; (2) documentation of all transfers of SNM between material-balance areas to show the identity and quantity of SNM transferred; (3) requirements for authorized signatures on each document used to record the transfer of SNM between material-balance areas; and (4) means for control of and accounting for internal transfer documents. Paragraph 70.58(e) requires licensees to establish, maintain, and follow a system for measuring the SNM transferred between material-balance areas and item-control areas. Paragraph 70.58(f) requires that licensees have a program that evaluates and controls the quality of their measurement system. Additionally, all licensees authorized to possess SNM must comply with paragraph 70.51(b) of 10 CFR Part 70. That rule requires licensees to keep records showing, among other things, the inventory of all SNM in their possession and its location. This guide sets forth acceptable methods for controlling and documenting transfers of SNM within a plant site in order to meet the requirements listed above

  16. Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt.

    Science.gov (United States)

    Aramaki, Hidefumi; Katoh, Munenori; Hiiragi, Yukinobu; Kawasaki, Tsubasa; Kurihara, Tomohisa; Ohmi, Yorikatsu

    2016-07-01

    [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects' right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson's product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.

  17. A practioner's view on Strategic Niche Management

    International Nuclear Information System (INIS)

    Mourik, R.; Raven, R.P.J.M.

    2006-11-01

    Strategic Niche Management (SNM) is a tool to support the societal introduction of radical sustainable innovations. However, it has been mainly used in retrospective to analyse historical case studies. This report discusses SNM from a practioner's perspective with the main aim to articulate questions that should be addressed for translating SNM from an ex-post to an ex-ante tool. The main conclusion is that an SNM tool should focus on the level of 'niches' rather than single projects, i.e. SNM should aim to support (program) managers who aim at orchestrating the interaction between multiple experiments

  18. Poor correlation between intracranial pressure and intraocular pressure by hand-held tonometry

    Directory of Open Access Journals (Sweden)

    Golan S

    2013-06-01

    Full Text Available Shani Golan,1 Shimon Kurtz,1 Daphna Mezad-Koursh,1 Michael Waisbourd,1 Anat Kesler,1 Pinchas Halpern2 1Departments of Ophthalmology, Tel Aviv Sourasky Medical Center, affiliated with the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; 2Emergency Medicine, Tel Aviv Sourasky Medical Center, affiliated with the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel Purpose: The aim of this study is to provide data on the controversial issue of whether handheld measurements of intraocular pressure (IOP are capable of accurately predicting elevated intracranial pressure (ICP in patients undergoing lumbar puncture (LP. Methods: All patients over the age of 18 years who underwent an LP in the emergency or neurological departments at the Tel Aviv Medical center for any reason between October 2007 and July 2010 were eligible to participate in this prospective observational pilot study. IOP was measured with the Tono-Pen XL while patients were in the supine position before undergoing LP. ICP was measured in the lateral recumbent position. ICP and bilateral IOP were measured, and the mean and maximum values of IOP were calculated. The association between ICP and each one of the four IOP measures was evaluated by the Pearson correlation coefficient. Results: Twenty-four patients (mean age 37.8 ± 15.8 years, ten males and 14 females were enrolled. The reasons for their requiring an LP were headache (19/24 patients, evaluation for hemiparesis (2/24, cognitive deterioration (1/24, and seizures (2/24. Nine had elevated mean opening pressure (>20 cm H2O, six had an elevated mean IOP (>20 mmHg, and four of these six also had an elevated opening pressure. There was no significant correlation between the ICP measurements and any of the IOP measurements. Conclusion: Handheld ocular tonometry has poor sensitivity and specificity for the prediction of increased ICP and is not an effective tool for screening for ICP in the ED or in the

  19. Radiation Detection for Homeland Security Applications

    Science.gov (United States)

    Ely, James

    2008-05-01

    In the past twenty years or so, there have been significant changes in the strategy and applications for homeland security. Recently there have been significant at deterring and interdicting terrorists and associated organizations. This is a shift in the normal paradigm of deterrence and surveillance of a nation and the `conventional' methods of warfare to the `unconventional' means that terrorist organizations resort to. With that shift comes the responsibility to monitor international borders for weapons of mass destruction, including radiological weapons. As a result, countries around the world are deploying radiation detection instrumentation to interdict the illegal shipment of radioactive material crossing international borders. These efforts include deployments at land, rail, air, and sea ports of entry in the US and in European and Asian countries. Radioactive signatures of concern include radiation dispersal devices (RDD), nuclear warheads, and special nuclear material (SNM). Radiation portal monitors (RPMs) are used as the main screening tool for vehicles and cargo at borders, supplemented by handheld detectors, personal radiation detectors, and x-ray imaging systems. This talk will present an overview of radiation detection equipment with emphasis on radiation portal monitors. In the US, the deployment of radiation detection equipment is being coordinated by the Domestic Nuclear Detection Office within the Department of Homeland Security, and a brief summary of the program will be covered. Challenges with current generation systems will be discussed as well as areas of investigation and opportunities for improvements. The next generation of radiation portal monitors is being produced under the Advanced Spectroscopic Portal program and will be available for deployment in the near future. Additional technologies, from commercially available to experimental, that provide additional information for radiation screening, such as density imaging equipment, will

  20. Compact printed two dipole array antenna with a high front-back ratio for ultra-high-frequency radio-frequency identification handheld reader applications

    DEFF Research Database (Denmark)

    Liu, Qi; Zhang, Shuai; He, Sailing

    2015-01-01

    A printed two-dipole array antenna with a high front-back ratio is proposed for ultra-high-frequency (UHF) radio-frequency identification handheld readers. The proposed antenna is a parasitic dual-element array with the ends of both elements folded back towards each other for additional coupling....

  1. Evaluation of Acquisition Strategies for Image-Based Construction Site Monitoring

    Science.gov (United States)

    Tuttas, S.; Braun, A.; Borrmann, A.; Stilla, U.

    2016-06-01

    Construction site monitoring is an essential task for keeping track of the ongoing construction work and providing up-to-date information for a Building Information Model (BIM). The BIM contains the as-planned states (geometry, schedule, costs, ...) of a construction project. For updating, the as-built state has to be acquired repeatedly and compared to the as-planned state. In the approach presented here, a 3D representation of the as-built state is calculated from photogrammetric images using multi-view stereo reconstruction. On construction sites one has to cope with several difficulties like security aspects, limited accessibility, occlusions or construction activity. Different acquisition strategies and techniques, namely (i) terrestrial acquisition with a hand-held camera, (ii) aerial acquisition using a Unmanned Aerial Vehicle (UAV) and (iii) acquisition using a fixed stereo camera pair at the boom of the crane, are tested on three test sites. They are assessed considering the special needs for the monitoring tasks and limitations on construction sites. The three scenarios are evaluated based on the ability of automation, the required effort for acquisition, the necessary equipment and its maintaining, disturbance of the construction works, and on the accuracy and completeness of the resulting point clouds. Based on the experiences during the test cases the following conclusions can be drawn: Terrestrial acquisition has the lowest requirements on the device setup but lacks on automation and coverage. The crane camera shows the lowest flexibility but the highest grade of automation. The UAV approach can provide the best coverage by combining nadir and oblique views, but can be limited by obstacles and security aspects. The accuracy of the point clouds is evaluated based on plane fitting of selected building parts. The RMS errors of the fitted parts range from 1 to a few cm for the UAV and the hand-held scenario. First results show that the crane camera

  2. EVALUATION OF ACQUISITION STRATEGIES FOR IMAGE-BASED CONSTRUCTION SITE MONITORING

    Directory of Open Access Journals (Sweden)

    S. Tuttas

    2016-06-01

    Full Text Available Construction site monitoring is an essential task for keeping track of the ongoing construction work and providing up-to-date information for a Building Information Model (BIM. The BIM contains the as-planned states (geometry, schedule, costs, ... of a construction project. For updating, the as-built state has to be acquired repeatedly and compared to the as-planned state. In the approach presented here, a 3D representation of the as-built state is calculated from photogrammetric images using multi-view stereo reconstruction. On construction sites one has to cope with several difficulties like security aspects, limited accessibility, occlusions or construction activity. Different acquisition strategies and techniques, namely (i terrestrial acquisition with a hand-held camera, (ii aerial acquisition using a Unmanned Aerial Vehicle (UAV and (iii acquisition using a fixed stereo camera pair at the boom of the crane, are tested on three test sites. They are assessed considering the special needs for the monitoring tasks and limitations on construction sites. The three scenarios are evaluated based on the ability of automation, the required effort for acquisition, the necessary equipment and its maintaining, disturbance of the construction works, and on the accuracy and completeness of the resulting point clouds. Based on the experiences during the test cases the following conclusions can be drawn: Terrestrial acquisition has the lowest requirements on the device setup but lacks on automation and coverage. The crane camera shows the lowest flexibility but the highest grade of automation. The UAV approach can provide the best coverage by combining nadir and oblique views, but can be limited by obstacles and security aspects. The accuracy of the point clouds is evaluated based on plane fitting of selected building parts. The RMS errors of the fitted parts range from 1 to a few cm for the UAV and the hand-held scenario. First results show that the crane

  3. A hand-held sensor for analyses of local distributions of magnetic fields and losses

    CERN Document Server

    Krismanic, G; Baumgartinger, N

    2000-01-01

    The paper describes a novel sensor for non-destructive analyses of local field and loss distributions in laminated soft magnetic cores, such as transformer cores. It was designed for rapid information on comparative local degrees of inhomogeneity, e.g., for the estimation of local building factors. Similar to a magnifying glass with handle, the compact hand-held sensor contains extremely sharp needle electrodes for the detection of the induction vector B as well as double-field coils for the vector H. Losses P are derived from the Poynting law. Applied to inner -- or also outer -- core regions, the sensor yields instantaneous computer displays of local H, B, and P.

  4. Detection of cadmium sulphide nanoparticles by using screen-printed electrodes and a handheld device

    International Nuclear Information System (INIS)

    Merkoci, Arben; Marcolino-Junior, Luiz Humberto; MarIn, Sergio; Fatibello-Filho, Orlando; Alegret, Salvador

    2007-01-01

    A simple method based on screen-printed electrodes and a handheld potentiostatic device is reported for the detection of water soluble CdS quantum dots modified with glutathione. The detection method is based on the stripping of electrochemically reduced cadmium at pH 7.0 by using square wave voltammetry. Various parameters that affect the sensitivity of the method are optimized. QD suspension volumes of 20 μl and a number of around 2 x 10 11 CdS quantum dots have been able to be detected. The proposed method should be of special interest for bioanalytical assays, where CdS quantum dots can be used as electrochemical tracers

  5. Sacral neuromodulation effects on periurethral sensation and urethral sphincter activity.

    Science.gov (United States)

    Gleason, Jonathan L; Kenton, Kimberly; Greer, W Jerod; Ramm, Olga; Szychowski, Jeff M; Wilson, Tracey; Richter, Holly E

    2013-06-01

    To characterize the effect of sacral neuromodulation (SNM) on urethral neuromuscular function. Following IRB approval, women with refractory overactive bladder (OAB) underwent standardized urethral testing prior to and after Stage 1 SNM implantation. Periurethral sensation was measured using current perception thresholds (CPT). Striated urethral sphincter activity was quantified using concentric needle electromyography (CNE) and Multi-Motor Unit Action Potential (MUP) analysis software. Nonparametric analyses were used to characterize pre/post changes with intervention. Baseline CPT and CNE findings were compared between SNM responders and non-responders. Twenty-seven women were enrolled in this pilot study with a mean age of 61 ± 13 years. Twenty of 26 women (76.9%) responded to SNM and went to Stage 2 permanent implantation. Four (14.8%) withdrew after Stage 1 implantation; three of the four withdrawals had not had therapeutic responses to SNM. CPT and CNE parameters did not significantly differ from baseline 2 weeks after SNM. Pre-SNM urethral sensation was not significantly different between responders and non-responders. However, responders had larger amplitude, longer duration and more turns and phases at baseline approaching significance, reflecting more successful urethral reinnervation, than non-responders. SNM does not alter urethral neuromuscular function 2 weeks post Stage 1 implantation. Copyright © 2012 Wiley Periodicals, Inc.

  6. Reliability of measuring hip abductor strength following total knee arthroplasty using a hand-held dynamometer.

    Science.gov (United States)

    Schache, Margaret B; McClelland, Jodie A; Webster, Kate E

    2016-01-01

    To investigate the test-retest reliability of measuring hip abductor strength in patients with total knee arthroplasty (TKA) using a hand-held dynamometer (HHD) with two different types of resistance: belt and manual resistance. Test-retest reliability of 30 subjects (17 female, 13 male, 71.9 ± 7.4 years old), 9.2 ± 2.7 days post TKA was measured using belt and therapist resistance. Retest reliability was calculated with intra-class coefficients (ICC3,1) and 95% confidence intervals (CI) for both the group average and the individual scores. A paired t-test assessed whether a difference existed between the belt and therapist methods of resistance. ICCs were 0.82 and 0.80 for the belt and therapist resisted methods, respectively. Hip abductor strength increases of 8 N (14%) for belt resisted and 14 N (17%) for therapist resisted measurements of the group average exceeded the 95% CI and may represent real change. For individuals, hip abductor strength increases of 33 N (72%) (belt resisted) and 57 N (79%) (therapist resisted) could be interpreted as real change. Hip abductor strength can be reliably measured using HHD in the clinical setting with the described protocol. Belt resistance demonstrated slightly higher test-retest reliability. Reliable measurement of hip abductor muscle strength in patients with TKA is important to ensure deficiencies are addressed in rehabilitation programs and function is maximized. Hip abductor strength can be reliably measured with a hand-held dynamometer in the clinical setting using manual or belt resistance.

  7. A review of the use of handheld computers in medical nutrition.

    Science.gov (United States)

    Holubar, Stefan; Harvey-Banchik, Lillian

    2007-08-01

    Handheld computers, or personal digital assistants (PDAs), have been used to assist clinicians in medical nutrition since the early 1980s. The term PDA was originally applied to programmable calculators; over time, the capabilities of these devices were expanded to allow for the use of more complicated programs such as databases, spreadsheets, and electronic books. Slowly, the device evolved into what is more commonly thought of as a PDA, that is, a device such as a PalmOS (PalmSource, Inc, Tokyo, Japan) or PocketPC (Microsoft, Redmond, WA) unit. We present a review of the literature about the use of PDAs in medical nutrition, followed by a discussion of the different types of PDAs and mobile technologies that are commercially available. This is followed by a discussion of software applications that are currently available for use by nutrition clinicians, focusing on freeware applications. Finally, future technologies and applications are discussed.

  8. Potential air contamination during CO2 angiography using a hand-held syringe: theoretical considerations and gas chromatography.

    Science.gov (United States)

    Cho, David R; Cho, Kyung J; Hawkins, Irvin F

    2006-01-01

    To assess air contamination in the hand-held syringes currently used for CO2 delivery and to determine whether there is an association between their position and the rate of air contamination. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO2 at 0.1599 cm2/sec (9.594 cm2/min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Air contamination occurs in hand-held syringes filled with CO2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions.

  9. Science education with handheld devices: A comparison of Nintendo WiiMote and iPod touch for kinematics learning

    OpenAIRE

    Hochberg, K.; Kuhn, J.; Müller, A.

    2016-01-01

    Experiential science learning based on the in-built sensors of handheld devices such as smartphones, tablet computer and game consoles has seen quite a strong development in recent years. In particular, such devices with internal acceleration sensors offer an innovative approach to kinematics learning in classroom physics, a notoriously difficult topic for pupils. In view of research and teaching in this domain, the practical advantages and disadvantages of two such devices, the Nintendo WiiM...

  10. Interpreting Mobile and Handheld Air Sensor Readings in Relation to Air Quality Standards and Health Effect Reference Values: Tackling the Challenges

    Directory of Open Access Journals (Sweden)

    George M. Woodall

    2017-09-01

    Full Text Available The US Environmental Protection Agency (EPA and other federal agencies face a number of challenges in interpreting and reconciling short-duration (seconds to minutes readings from mobile and handheld air sensors with the longer duration averages (hours to days associated with the National Ambient Air Quality Standards (NAAQS for the criteria pollutants-particulate matter (PM, ozone, carbon monoxide, lead, nitrogen oxides, and sulfur oxides. Similar issues are equally relevant to the hazardous air pollutants (HAPs where chemical-specific health effect reference values are the best indicators of exposure limits; values which are often based on a lifetime of continuous exposure. A multi-agency, staff-level Air Sensors Health Group (ASHG was convened in 2013. ASHG represents a multi-institutional collaboration of Federal agencies devoted to discovery and discussion of sensor technologies, interpretation of sensor data, defining the state of sensor-related science across each institution, and provides consultation on how sensors might effectively be used to meet a wide range of research and decision support needs. ASHG focuses on several fronts: improving the understanding of what hand-held sensor technologies may be able to deliver; communicating what hand-held sensor readings can provide to a number of audiences; the challenges of how to integrate data generated by multiple entities using new and unproven technologies; and defining best practices in communicating health-related messages to various audiences. This review summarizes the challenges, successes, and promising tools of those initial ASHG efforts and Federal agency progress on crafting similar products for use with other NAAQS pollutants and the HAPs. NOTE: The opinions expressed are those of the authors and do not necessary represent the opinions of their Federal Agencies or the US Government. Mention of product names does not constitute endorsement.

  11. WWC Review of the Report "Conceptualizing Astronomical Scale: Virtual Simulations on Handheld Tablet Computers Reverse Misconceptions." What Works Clearinghouse Single Study Review

    Science.gov (United States)

    What Works Clearinghouse, 2014

    2014-01-01

    The 2014 study, "Conceptualizing Astronomical Scale: Virtual Simulations on Handheld Tablet Computers Reverse Misconceptions," examined the effects of using the true-to-scale (TTS) display mode versus the orrery display mode in the iPad's Solar Walk software application on students' knowledge of the Earth's place in the solar system. The…

  12. Clinical effectiveness of the Respimat® inhaler device in managing chronic obstructive pulmonary disease: evidence when compared with other handheld inhaler devices

    Directory of Open Access Journals (Sweden)

    et al

    2011-02-01

    Full Text Available Felix SF Ram1, Celso R Carvallho2, John White31School of Health and Social Services, Massey University, Auckland, New Zealand; 2Department of Physical Therapy, School of Medicine, University of São Paulo, Brazil; 3York Hospitals NHS Foundation Trust, York Hospital, York, UKObjectives: Medication for the management of chronic obstructive pulmonary disease (COPD may be delivered by a number of different inhaler devices. This study was undertaken to determine the clinical effectiveness of the Respimat® handheld inhaler device compared with other handheld inhaler devices for the delivery of medication in stable COPD.Methodology: A systematic review of high-quality randomized controlled clinical trials comparing Respimat with other inhaler devices using the same medication was performed. Studies were searched for in the Cochrane Central Register of Controlled Trials as well as other relevant electronic databases. Manufacturers of inhaled COPD medication were also contacted for potential trials.Results: Seven studies of high methodological quality with 3813 participants were included in the review. Three trials used Handihaler® as the comparator inhaler, three used a chlorofluorocarbon metered-dose inhaler (CFC-MDI, and one trial used a hydroflouroalkane (HFA-MDI. When Respimat was compared with Handihaler, the following reported outcomes were not significantly different: trough forced expiratory volume in 1 second (FEV1 (weighted mean difference [WMD] 0.01 L; P = 0.14, trough forced vital capacity (FVC (WMD 0.001 L: P = 0.88, peak FEV1 (WMD 0.01 L: P = 0.08, peak FVC (WMD 0.01 L: P = 0.55, morning peak expiratory flow rate (PEFR (WMD 5.06 L/min: P = 0.08, and evening PEFR (WMD 4.39 L/min: P = 0.15. Furthermore, there were no differences when Respimat was compared with Handihaler for risk of exacerbations (relative risk [RR] 0.94: P = 0.81, dry mouth (RR 1.57: P = 0.34, or nasopharyngitis (RR 1.42: P = 0.22. For Respimat compared with CFC-MDI, the

  13. Photoacoustic cystography using handheld dual modal clinical ultrasound photoacoustic imaging system

    Science.gov (United States)

    Sivasubramanian, Kathyayini; Periyasamy, Vijitha; Austria, Dienzo Rhonnie; Pramanik, Manojit

    2018-02-01

    Vesicoureteral reflux is the abnormal flow of urine from your bladder back up the tubes (ureters) that connect your kidneys to your bladder. Normally, urine flows only down from your kidneys to your bladder. Vesicoureteral reflux is usually diagnosed in infants and children. The disorder increases the risk of urinary tract infections, which, if left untreated, can lead to kidney damage. X-Ray cystography is used currently to diagnose this condition which uses ionising radiation, making it harmful for patients. In this work we demonstrate the feasibility of imaging the urinary bladder using a handheld clinical ultrasound and photoacoustic dual modal imaging system in small animals (rats). Additionally, we demonstrate imaging vesicoureteral reflux using bladder mimicking phantoms. Urinary bladder imaging is done with the help of contrast agents like black ink and gold nanoparticles which have high optical absorption at 1064 nm. Imaging up to 2 cm was demonstrated with this system. Imaging was done at a framerate of 5 frames per second.

  14. Textbooks on tap: using electronic books housed in handheld devices in nursing clinical courses.

    Science.gov (United States)

    Williams, Margaret G; Dittmer, Arlis

    2009-01-01

    Changing technology is creating new ways to approach nursing education and practice. Beginning in 2003, using a quasi-experimental design, this project introduced personal digital assistants (PDAs) as a clinical tool to five experimental and control groups of students and faculty. The handheld device, or PDA, was loaded with e-books for clinical practice. Differences in learning styles and preferences emerged during the different phases of the study. Students were quickly able to master the technology and use the device effectively, reporting that they liked the concise nature of the information obtained. No students expressed dissatisfaction or regret at being in the experimental group. Results and implications for clinical practice, education, and library resources are discussed.

  15. An improved characterization method for international accountancy measurements of fresh and irradiated mixed oxide (MOX) fuel: helping achieve continual monitoring and safeguards through the fuel cycle

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Louise G [Los Alamos National Laboratory; Croft, Stephen [Los Alamos National Laboratory; Swinhoe, Martyn T [Los Alamos National Laboratory; Tobin, S. J. [Los Alamos National Laboratory; Menlove, H. O. [Los Alamos National Laboratory; Schear, M. A. [Los Alamos National Laboratory; Worrall, Andrew [U.K. NNL

    2011-01-13

    Nuclear fuel accountancy measurements are conducted at several points through the nuclear fuel cycle to ensure continuity of knowledge (CofK) of special nuclear material (SNM). Non-destructive assay (NDA) measurements are performed on fresh fuel (prior to irradiation in a reactor) and spent nuclear fuel (SNF) post-irradiation. We have developed a fuel assembly characterization system, based on the novel concept of 'neutron fingerprinting' with multiplicity signatures to ensure detailed CofK of nuclear fuel through the entire fuel cycle. The neutron fingerprint in this case is determined by the measurement of the various correlated neutron signatures, specific to fuel isotopic composition, and therefore offers greater sensitivity to variations in fissile content among fuel assemblies than other techniques such as gross neutron counting. This neutron fingerprint could be measured at the point of fuel dispatch (e.g. from a fuel fabrication plant prior to irradiation, or from a reactor site post-irradiation), monitored during transportation of the fuel assembly, and measured at a subsequent receiving site (e.g. at the reactor site prior to irradiation, or reprocessing facility post-irradiation); this would confirm that no unexpected changes to the fuel composition or amount have taken place during transportation and/ or reactor operations. Changes may indicate an attempt to divert material for example. Here, we present the current state of the practice of fuel measurements for both fresh mixed oxide (MOX) fuel and SNF (both MOX and uranium dioxide). This is presented in the framework of international safeguards perspectives from the US and UK. We also postulate as to how the neutron fingerprinting concept could lead to improved fuel characterization (both fresh MOX and SNF) resulting in: (a) assured CofK of fuel across the nuclear fuel cycle, (b) improved detection of SNM diversion, and (c) greater confidence in safeguards of SNF transportation.

  16. Direction-Sensitive Hand-Held Gamma-Ray Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Mukhopadhyay, S.

    2012-10-04

    A novel, light-weight, hand-held gamma-ray detector with directional sensitivity is being designed. The detector uses a set of multiple rings around two cylindrical surfaces, which provides precise location of two interaction points on two concentric cylindrical planes, wherefrom the source location can be traced back by back projection and/or Compton imaging technique. The detectors are 2.0 × 2.0 mm europium-doped strontium iodide (SrI2:Eu2+) crystals, whose light output has been measured to exceed 120,000 photons/MeV, making it one of the brightest scintillators in existence. The crystal’s energy resolution, less than 3% at 662 keV, is also excellent, and the response is highly linear over a wide range of gamma-ray energies. The emission of SrI2:Eu2+ is well matched to both photo-multiplier tubes and blue-enhanced silicon photodiodes. The solid-state photomultipliers used in this design (each 2.0 × 2.0 mm) are arrays of active pixel sensors (avalanche photodiodes driven beyond their breakdown voltage in reverse bias); each pixel acts as a binary photon detector, and their summed output is an analog representation of the total photon energy, while the individual pixel accurately defines the point of interaction. A simple back-projection algorithm involving cone-surface mapping is being modeled. The back projection for an event cone is a conical surface defining the possible location of the source. The cone axis is the straight line passing through the first and second interaction points.

  17. Handheld Computers for Malaria Monitoring (Mozambique) | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Malaria is the principal cause of morbidity and mortality in Mozambique and is considered a major impediment to development. The effectiveness of any malaria control program depends on reliable data delivered in timely fashion, something that is currently lacking in the nation's health service. This grant will allow the ...

  18. Handheld Computers for Malaria Monitoring (Mozambique) | CRDI ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Malaria is the principal cause of morbidity and mortality in Mozambique and is considered a major impediment to development. The effectiveness of any malaria control program depends on reliable data delivered in timely fashion, something that is currently lacking in the nation's health service. This grant will allow the ...

  19. Potential Air Contamination During CO2 Angiography Using a Hand-Held Syringe: Theoretical Considerations and Gas Chromatography

    International Nuclear Information System (INIS)

    Cho, David R.; Cho, Kyung J.; Hawkins, Irvin F.

    2006-01-01

    Purpose. To assess air contamination in the hand-held syringes currently used for CO 2 delivery and to determine whether there is an association between their position and the rate of air contamination. Methods. Assessment of air contamination in the syringe (20 ml) included theoretical modeling, mathematical calculation, and gas chromatography (GC). The model was used with Fick's first law to calculate the diffusion of CO 2 and the amount of air contamination. For GC studies, the syringes were placed in the upright, horizontal, and inverted positions and gas samples were obtained after 5, 10, 20, 30, and 60 min. All trials with each position for each sampling time were performed five times. Results. The amounts of air contamination with time calculated mathematically were 5-10% less than those of GC. With the diffusivity of air-CO 2 at 0.1599 cm 2 /sec (9.594 cm 2 /min), air contamination was calculated to be 60% at 60 min. With GC air contamination was 13% at 5 min, 31% at 20 min, 43% at 30 min, and 68% at 60 min. There was no difference in air contamination between the different syringe positions. Conclusion. Air contamination occurs in hand-held syringes filled with CO 2 when they are open to the ambient air. The amounts of air contamination over time are similar among syringes placed in the upright, horizontal, and inverted positions

  20. Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.

    Science.gov (United States)

    Mair, B; Drillich, M; Klein-Jöbstl, D; Kanz, P; Borchardt, S; Meyer, L; Schwendenwein, I; Iwersen, M

    2016-02-24

    Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). The results of this study demonstrate good performance characteristics for the GLX

  1. Clinical assessment of hip strength using a hand-held dynamometer is reliable

    DEFF Research Database (Denmark)

    Thorborg, K; Petersen, J; Magnusson, S P

    2010-01-01

    rotation (ER), internal rotation (IR), flexion (FLEX) and extension (EXT) using a hand-held dynamometer. Nine subjects (five males, four females), physically active for at least 2.5 h a week, were included. Twelve standardized isometric strength tests were performed twice with a 1-week interval in between......Hip strength assessment plays an important role in the clinical examination of the hip and groin region. The primary aim of this study was to examine the absolute test-retest measurement variation concerning standardized strength assessments of hip abduction (ABD), adduction (ADD), external...... by the same examiner. The test order was randomized to avoid systematic bias. Measurement variation between sessions was 3-12%. When the maximum value of four measurements was used, test-retest measurement variation was below 10% in 11 of the 12 individual hip strength tests and below 5% in five of the 12...

  2. Inter-Tester Reliability and Precision of Manual Muscle Testing and Hand-Held Dynamometry in Lower Limb Muscles of Children with Spina Bifida

    Science.gov (United States)

    Mahony, Kate; Hunt, Adrienne; Daley, Deborah; Sims, Susan; Adams, Roger

    2009-01-01

    Reliability and measurement precision of manual muscle testing (MMT) and hand-held dynamometry (HHD) were compared for children with spina bifida. Strength measures were obtained of the hip flexors, hip abductors, and knee extensors of 20 children (10 males, 10 females; mean age 9 years 10 months; range: 5 to 15 years) by two experienced physical…

  3. Attentionally splitting the mass distribution of hand-held rods.

    Science.gov (United States)

    Burton, G; Turvey, M T

    1991-08-01

    Two experiments on the length-perception capabilities of effortful or dynamic touch differed only in terms of what the subject intended to perceive, while experimental conditions and apparatus were held constant. In each trial, a visually occluded rod was held as still as possible by the subject at an intermediate position. For two thirds of the trials, a weight was attached to the rod above or below the hand. In Experiment 1, in which the subject's task was to perceive the distance reachable with the portion of the rod forward of the hand, perceived extent was a function of the first moment of the mass distribution associated with the forward portion of the rod, and indifferent to the first moment of the entire rod. In Experiment 2, in which the task was to perceive the distance reachable with the entire rod if it was held at an end, the pattern of results was reversed. These results indicate the capability of selective sensitivity to different aspects of a hand-held object's mass distribution, without the possibility of differential exploration specific to these two tasks. Results are discussed in relation to possible roles of differential information, intention, and self-organization in the explanations of selective perceptual abilities.

  4. Nuclear material control and accounting safeguards in the United States

    International Nuclear Information System (INIS)

    Woltermann, H.A.; Rudy, C.R.; Rakel, D.A.; DeVer, E.A.

    1982-01-01

    Material control and accounting (MC and A) of special nuclear material (SNM) must supplement physical security to protect SNM from unlawful use such as terrorist activities. This article reviews MC and A safeguards of SNM in the United States. The following topics are covered: a brief perspective and history of MC and A safeguards, current MC and A practices, measurement methods for SNM, historical MC and A performance, a description of near-real-time MC and A systems, and conclusions on the status of MC and A in the United States

  5. Mobile Testing of Cognitive Function : A tool for assessment of cognitive abilities in an everyday environment using a handheld device

    OpenAIRE

    Fouchenette, Kim

    2011-01-01

    The unit of Cognitive Developmental Neuroscience at Karolinska Institutet have developed a method for measuring cognitive performance with handheld devices, which resulted in a mobile application for the iPod Touch. The application was previously used in a clinical trial with individuals suffering from chronic stress disorder, but had to be further developed. The application, which consisted of cognitive tests and questionnaires, required improvements that could be divided into three parts: (...

  6. Measurement control program for nuclear material accounting

    International Nuclear Information System (INIS)

    Brouns, R.J.; Roberts, F.P.; Merrill, J.A.; Brown, W.B.

    1980-06-01

    A measurement control program for nuclear material accounting monitors and controls the quality of the measurments of special nuclear material that are involved in material balances. The quality is monitored by collecting data from which the current precision and accuracy of measurements can be evaluated. The quality is controlled by evaluations, reviews, and other administrative measures for control of selection or design of facilities, equipment and measurement methods and the training and qualification of personnel who perform SNM measurements. This report describes the most important elements of a program by which management can monitor and control measurement quality

  7. Engineered Antibodies for Monitoring of Polynuclear Aromatic Hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Alexander E. Karu Ph.D; Victoria A. Roberts Ph.D.; Qing X. Li, Ph.D.

    2002-01-17

    This project was undertaken to fill needs in ODE's human and ecosystem health effects research, site remediation, rapid emergency response, and regulatory compliance monitoring programs. Doe has greatly stimulated development and validation of antibody-based, rapid, field-portable detection systems for small hazardous compounds. These range from simple dipsticks, microplate enzyme-linked immunosorbent assays (ELISAs), and hand-held colorimeters, to ultrasensitive microfluidic reactors, fiber-optic sensors and microarrays that can identify multiple analytes from patterns of cross-reactivity. Unfortunately, the technology to produce antibodies with the most desirable properties did not keep pace. Lack of antibodies remains a limiting factor in production and practical use of such devices. The goals of our project were to determine the chemical and structural bases for the antibody-analyte binding interactions using advanced computational chemistry, and to use this information to create useful new binding properties through in vitro genetic engineering and combinatorial library methods.

  8. Intrarater reliabilities of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer for geriatric and stroke patients

    OpenAIRE

    Hirano, Masahiro; Katoh, Munenori; Kawaguchi, Saori; Uemura, Tomomi

    2016-01-01

    [Purpose] This study aimed to verify the appropriate number of measurements and the intrarater reliabilities of shoulder joint horizontal adductor muscle strength measurements using a handheld dynamometer (HHD) for geriatric and stroke patients. [Subjects and Methods] The subjects were 40 inpatients, who were divided into two groups: 20 stroke patients in the stroke group (SG), and 20 geriatric patients in the no-stroke group (N-SG). Measurements were performed three times using an HHD with a...

  9. Assessment of isometric muscle strength and rate of torque development with hand-held dynamometry: Test-retest reliability and relationship with gait velocity after stroke.

    Science.gov (United States)

    Mentiplay, Benjamin F; Tan, Dawn; Williams, Gavin; Adair, Brooke; Pua, Yong-Hao; Bower, Kelly J; Clark, Ross A

    2018-04-27

    Isometric rate of torque development examines how quickly force can be exerted and may resemble everyday task demands more closely than isometric strength. Rate of torque development may provide further insight into the relationship between muscle function and gait following stroke. Aims of this study were to examine the test-retest reliability of hand-held dynamometry to measure isometric rate of torque development following stroke, to examine associations between strength and rate of torque development, and to compare the relationships of strength and rate of torque development to gait velocity. Sixty-three post-stroke adults participated (60 years, 34 male). Gait velocity was assessed using the fast-paced 10 m walk test. Isometric strength and rate of torque development of seven lower-limb muscle groups were assessed with hand-held dynamometry. Intraclass correlation coefficients were calculated for reliability and Spearman's rho correlations were calculated for associations. Regression analyses using partial F-tests were used to compare strength and rate of torque development in their relationship with gait velocity. Good to excellent reliability was shown for strength and rate of torque development (0.82-0.97). Strong associations were found between strength and rate of torque development (0.71-0.94). Despite high correlations between strength and rate of torque development, rate of torque development failed to provide significant value to regression models that already contained strength. Assessment of isometric rate of torque development with hand-held dynamometry is reliable following stroke, however isometric strength demonstrated greater relationships with gait velocity. Further research should examine the relationship between dynamic measures of muscle strength/torque and gait after stroke. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Physical protection of special nuclear material in the commercial fuel cycle. Volume I. Executive summary

    International Nuclear Information System (INIS)

    1976-04-01

    This is the summary of the work and recommendations resulting from Sandia's participation in the Special Safeguards Study, which covered three areas: protection of SNM at fixed facilities, protection of SNM while in transit, and relocation and recovery of lost SNM. The results are published in full in five other volumes. 6 tables, 4 fig

  11. A novel fully integrated handheld gamma camera

    International Nuclear Information System (INIS)

    Massari, R.; Ucci, A.; Campisi, C.; Scopinaro, F.; Soluri, A.

    2016-01-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  12. A novel fully integrated handheld gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Massari, R.; Ucci, A.; Campisi, C. [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy); Scopinaro, F. [University of Rome “La Sapienza”, S. Andrea Hospital, Rome (Italy); Soluri, A., E-mail: alessandro.soluri@ibb.cnr.it [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy)

    2016-10-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  13. Quantitative evaluation of a handheld light microscope for field diagnosis of soil-transmitted helminth infection.

    Science.gov (United States)

    Bogoch, Isaac I; Andrews, Jason R; Speich, Benjamin; Ame, Shaali M; Ali, Said M; Stothard, J Russell; Utzinger, Jürg; Keiser, Jennifer

    2014-12-01

    We evaluated the Newton Nm1, a commercially available handheld light microscope and compared it with conventional light microscopy for the diagnosis of soil-transmitted helminth infections. A total of 91 Kato-Katz thick smears were examined by experienced microscopists and helminth eggs were counted and expressed as eggs per gram of stool (EPG). Mean egg counts were significantly higher with the conventional light microscope (5,190 EPG versus 2,386 EPG for Ascaris lumbricoides; 826 versus 456 for Trichuris trichiura; both P Newton Nm1 microscope may be a useful tool for the detection and quantification of soil-transmitted helminth infection in clinical, epidemiologic, and public health settings. © The American Society of Tropical Medicine and Hygiene.

  14. Telemedicine and Alzheimer's Disease from Studio-Based Videoconferencing to Mobile Handheld Cell Phones

    Directory of Open Access Journals (Sweden)

    Pk (Poh-Kooi Loh

    2009-01-01

    Full Text Available The use of Telemedicine in the assessment of cognitive impairment and Alzheimer's Disease is evolving with advances in Information and Communication Technology. This article outlines the course of evolution in Western Australia, a large state with a sparse population outside of the capital city. The starting point of the evolution, video-conferencing in Telehealth studios, is reviewed as well as the next stage, use of desktop technology, which enables the physician to consult from the office or clinic. A pilot study currently being undertaken to assess the validity of the latest stage in evolution of Telehealth—the use of handheld mobile cell phone video calling that allows the physician and patient to interact at locations convenient to both parties. The pitfalls and implications of the use of this stage, should it prove to be a valid approach, are discussed.

  15. Handheld readout electronics to fully exploit the particle discrimination capabilities of elpasolite scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Budden, B.S., E-mail: bbudden@lanl.gov [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Stonehill, L.C.; Warniment, A.; Michel, J.; Storms, S.; Dallmann, N.; Coupland, D.D.S.; Stein, P.; Weller, S.; Borges, L.; Proicou, M.; Duran, G. [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Kamto, J. [Intelligence and Space Research Division, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Electrical & Computer Engineering Department, Praire View A& M University, Prairie View, TX 77446 (United States)

    2015-09-21

    A new class of elpasolite scintillators has garnered recent attention due to the ability to perform as simultaneous gamma spectrometers and thermal neutron detectors. Such a dual-mode capability is made possible by pulse-shape discrimination (PSD), whereby the emission waveform profiles of gamma and neutron events are fundamentally unique. To take full advantage of these materials, we have developed the Compact Advanced Readout Electronics for Elpasolites (CAREE). This handheld instrument employs a multi-channel PSD-capable ASIC, custom micro-processor board, front-end electronics, power supplies, and a 2 in. photomultiplier tube for readout of the scintillator. The unit is highly configurable to allow for performance optimization amongst a wide sample of elpasolites which provide PSD in fundamentally different ways. We herein provide an introduction to elpasolites, then describe the motivation for the work, mechanical and electronic design, and preliminary performance results.

  16. Digital knowledge in the coat pocket - hand-held personal digital assistants in radiology

    International Nuclear Information System (INIS)

    Niehues, S.M.; Froehlich, M.; Felix, R.; Lemke, A.J.

    2004-01-01

    The personal digital assistant (PDA) enables the independent access to large data in a pocket-sized format. The applications for hand-held computers are growing steadily and can support almost any kind of problem. An overview of the available hardware and software is provided and evaluated. Furthermore, the use of the PDA in the clinical daily routine is described. In view of the numerous software programs available in radiology, the range of software solutions for radiologists is presented. Despite the high acquisition cost, the PDA has already become the digital assistant for the radiologist. After a short time of getting used to the PDA, nobody wants to miss it at work or at home. New technical features and available software programs will continuously increase the integration of the PDA into the medical workflow in the near future. (orig.)

  17. Hand-held Raman sensor head for in-situ characterization of meat quality applying a microsystem 671 nm diode laser

    Science.gov (United States)

    Schmidt, Heinar; Sowoidnich, Kay; Maiwald, Martin; Sumpf, Bernd; Kronfeldt, Heinz-Detlef

    2009-05-01

    A hand-held Raman sensor head was developed for the in-situ characterization of meat quality. As light source, a microsystem based external cavity diode laser module (ECDL) emitting at 671 nm was integrated in the sensor head and attached to a miniaturized optical bench which contains lens optics for excitation and signal collection as well as a Raman filter stage for Rayleigh rejection. The signal is transported with an optical fiber to the detection unit which was in the initial phase a laboratory spectrometer with CCD detector. All elements of the ECDL are aligned on a micro optical bench with 13 x 4 mm2 footprint. The wavelength stability is provided by a reflection Bragg grating and the laser has an optical power of up to 200 mW. However, for the Raman measurements of meat only 35 mW are needed to obtain Raman spectra within 1 - 5 seconds. Short measuring times are essential for the hand-held device. The laser and the sensor head are characterized in terms of stability and performance for in-situ Raman investigations. The function is demonstrated in a series of measurements with raw and packaged pork meat as samples. The suitability of the Raman sensor head for the quality control of meat and other products will be discussed.

  18. Initial Experience with a Handheld Device Digital Imaging and Communications in Medicine Viewer: OsiriX Mobile on the iPhone

    OpenAIRE

    Choudhri, Asim F.; Radvany, Martin G.

    2010-01-01

    Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility o...

  19. Three-dimensional modeling of physiological tremor for hand-held surgical robotic instruments.

    Science.gov (United States)

    Tatinati, Sivanagaraja; Yan Naing Aye; Pual, Anand; Wei Tech Ang; Veluvolu, Kalyana C

    2016-08-01

    Hand-held robotic instruments are developed to compensate physiological tremor in real-time while augmenting the required precision and dexterity into normal microsurgical work-flow. The hardware (sensors and actuators) and software (causal linear filters) employed for tremor identification and filtering introduces time-varying unknown phase-delay that adversely affects the device performance. The current techniques that focus on three-dimensions (3D) tip position control involves modeling and canceling the tremor in 3-axes (x, y, and z axes) separately. Our analysis with the tremor data recorded from surgeons and novice subjects show that there exists significant correlation in tremor motion across the dimensions. Motivated by this, a new multi-dimensional modeling approach based on extreme learning machines (ELM) is proposed in this paper to correct the phase delay and to accurately model tremulous motion in three dimensions simultaneously. A study is conducted with tremor data recorded from the microsurgeons to analyze the suitability of proposed approach.

  20. SAFEGUARDS ENVELOPE: PREVIOUS WORK AND EXAMPLES

    International Nuclear Information System (INIS)

    Metcalf, Richard; Bevill, Aaron; Charlton, William; Bean, Robert

    2008-01-01

    The future expansion of nuclear power will require not just electricity production but fuel cycle facilities such as fuel fabrication and reprocessing plants. As large reprocessing facilities are built in various states, they must be built and operated in a manner to minimize the risk of nuclear proliferation. Process monitoring has returned to the spotlight as an added measure that can increase confidence in the safeguards of special nuclear material (SNM). Process monitoring can be demonstrated to lengthen the allowable inventory period by reducing accountancy requirements, and to reduce the false positive indications. The next logical step is the creation of a Safeguards Envelope, a set of operational parameters and models to maximize anomaly detection and inventory period by process monitoring while minimizing operator impact and false positive rates. A brief example of a rudimentary Safeguards Envelope is presented, and shown to detect synthetic diversions overlaying a measured processing plant data set. This demonstration Safeguards Envelope is shown to increase the confidence that no SNM has been diverted with minimal operator impact, even though it is based on an information sparse environment. While the foundation on which a full Safeguards Envelope can be built has been presented in historical demonstrations of process monitoring, several requirements remain yet unfulfilled. Future work will require reprocessing plant transient models, inclusion of 'non-traditional' operating data, and exploration of new methods of identifying subtle events in transient processes

  1. New PAMTRAK video and interface capabilities

    International Nuclear Information System (INIS)

    Anspach, J.

    1994-01-01

    The Department of Energy (DOE) mission is changing due to the number of nuclear weapon reductions by the United States and the former Soviet Union, and increasing long-term storage requirements for DOE sites. New techniques to ensure the integrity of special nuclear material (SNM) in storage are available to sites to supplement manual physical inventories, thus allowing them to decrease operating costs while keeping radiation exposure at minimal levels. To help ensure the integrity of SNM Sandia National Laboratories has developed a generic, real time, personnel tracking and material monitoring system named PAMTRAK. PAMTRAK can significantly reduce the number of required manual physical inventories at DOE sites while increasing assurance that an insider has not diverted or stolen material. This paper describes two new capabilities that we have recently added to PAMTRAK; a video motion detection subsystem, and a communication interface to other systems

  2. Beyond Textbook Illustrations: Hand-Held Models of Ordered DNA and Protein Structures as 3D Supplements to Enhance Student Learning of Helical Biopolymers

    Science.gov (United States)

    Jittivadhna, Karnyupha; Ruenwongsa, Pintip; Panijpan, Bhinyo

    2010-01-01

    Textbook illustrations of 3D biopolymers on printed paper, regardless of how detailed and colorful, suffer from its two-dimensionality. For beginners, computer screen display of skeletal models of biopolymers and their animation usually does not provide the at-a-glance 3D perception and details, which can be done by good hand-held models. Here, we…

  3. Non-streaming high-efficiency perforated semiconductor neutron detectors, methods of making same and measuring wand and detector modules utilizing same

    Science.gov (United States)

    McGregor, Douglas S.; Shultis, John K.; Rice, Blake B.; McNeil, Walter J.; Solomon, Clell J.; Patterson, Eric L.; Bellinger, Steven L.

    2010-12-21

    Non-streaming high-efficiency perforated semiconductor neutron detectors, method of making same and measuring wands and detector modules utilizing same are disclosed. The detectors have improved mechanical structure, flattened angular detector responses, and reduced leakage current. A plurality of such detectors can be assembled into imaging arrays, and can be used for neutron radiography, remote neutron sensing, cold neutron imaging, SNM monitoring, and various other applications.

  4. Safeguards instrument to monitor spent reactor fuel

    International Nuclear Information System (INIS)

    Nicholson, N.; Dowdy, E.J.; Holt, D.M.; Stump, C.

    1981-01-01

    A hand-held instrument for monitoring irradiated nuclear fuel inventories located in water-filled storage ponds has been developed. This instrument provides sufficient precise qualitative and quantitative information to be useful as a confirmatory technique to International Atomic Energy Agency inspectors, and is believed to be of potential use to nuclear fuel managers and to operators of spent-fuel storage facilities, both at reactor and away-from-reactor, and to operators of nuclear fuel reprocessing plants. Because the Cerenkov radiation glow can barely be seen by the unaided eye under darkened conditions, a night vision device is incorporated to aid the operator in locating the fuel assembly to be measured. Beam splitting optics placed in front of the image intensifier and a preset aperture select a predetermined portion of the observed scene for measurement of the light intensity using a photomultiplier (PM) tube and digital readout. The PM tube gain is adjusted by use of an internal optical reference source, providing long term repeatability and instrument-to-instrument cnsistency. Interchangeable lenses accommodate various viewing and measuring conditions

  5. Mobile real-time data acquisition system for application in preventive medicine.

    Science.gov (United States)

    Neubert, Sebastian; Arndt, Dagmar; Thurow, Kerstin; Stoll, Regina

    2010-05-01

    In this article, the development of a system for online monitoring of a subject's physiological parameters and subjective workload regardless of location has been presented, which allows for studies on occupational health. In the sector of occupational health, modern acquisition systems are needed. Such systems can be used by the subject during usual daily routines without being influenced by the presence of an examiner. Moreover, the system's influence on the subject should be reduced to a minimum to receive reliable data from the examination. The acquisition system is based on a mobile handheld (or smart phone), which allows both management of the communication process and input of several dialog data (e.g., questionnaires). A sensor electronics module permits the acquisition of different physiological parameters and their online transmission to the handheld via Bluetooth. The mobile handheld and the sensor electronics module constitute a wireless personal area network. The handheld allows the first analysis, the synchronization of the data, and the continuous data transfer to a communication server by the integrated mobile radio standards of the handheld. The communication server stores the incoming data of several subjects in an application-dependent database and allows access from all over the world via a Web-based management system. The developed system permits one examiner to monitor the physiological parameters and the subjective workload of several subjects in different locations at the same time. Thereby the subjects can move almost freely in any area covered by the mobile network. The mobile handheld allows the popping-up of the questionnaires at flexible time intervals. This electronic input of the dialog data, in comparison to the manual documentation on papers, is more comfortable to the subject as well as to the examiner for an analysis. A Web-based management application facilitates a continuous remote monitoring of the physiological and the

  6. Evaluation of Handheld Scanners for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Wadea Ameen

    2018-01-01

    Full Text Available The process of generating a computerized geometric model for an existing part is known as Reverse Engineering (RE. It is a very useful technique in product development and plays a significant role in automotive, aerospace, and medical industries. In fact, it has been getting remarkable attention in manufacturing industries owing to its advanced data acquisition technologies. The process of RE is based on two primary steps: data acquisition (also known as scanning and data processing. To facilitate point data acquisition, a variety of scanning systems is available with different capabilities and limitations. Although the optical control of 3D scanners is fully developed, still several factors can affect the quality of the scanned data. As a result, the proper selection of scanning parameters, such as resolution, laser power, shutter time, etc., becomes very crucial. This kind of investigation can be very helpful and provide its users with guidelines to identify the appropriate factors. Moreover, it is worth noting that no single system is ideal in all applications. Accordingly, this work has compared two portable (handheld systems based on laser scanning and white light optical scanning for automotive applications. A car door containing a free-form surface has been used to achieve the above-mentioned goal. The design of experiments has been employed to determine the effects of different scanning parameters and optimize them. The capabilities and limitations have been identified by comparing the two scanners in terms of accuracy, scanning time, triangle numbers, ease of use, and portability. Then, the relationships between the system capabilities and the application requirements have been established. The results revealed that the laser scanner performed better than the white light scanner in terms of accuracy, while the white light scanner performed better in terms of acquisition speed and triangle numbers.

  7. Development of an advanced safeguards system as a proliferation deterrent

    International Nuclear Information System (INIS)

    Ayers, A.A.; Barnes, L.D.

    1978-11-01

    The Advanced Safeguards System consists of Computerized Nuclear Materials Control and Accounting System, Physical Protection System, and Safeguards Coordination Center (SCC). Should all the computer-based monitoring systems be overcome (i.e., the NMC computer programmed not to recognize a materials inventory change, the SCC computer programmed to accept a falsified area and personnel authorization, and the physical security system programmed not to alarm for area intrusion), the requirements of the physical security system remain formidable barriers to successful theft since all SNM is separated from the uncontrolled areas by at least one entry control portal. An egress from the protected area--by either a vehicle through the vehicle access portal, or on foot through the personnel access portal--requires that the individuals be subjected to a search for metal and SNM before egress is permitted. The material access areas are further controlled by an interior access portal imposing the same SNM and metal search criteria. The portal search criteria are not subject to computer interpretation, but direct positive--negative indications to the portal patrolman. The physical security system then provides an independent backup should the computerized systems be defeated. Thus, the computer systems themselves will not, if defeated, guarantee an adversary success. The corollary also holds true; a defeat of the physical search elements of the physical security system will not guarantee adversary success because of the monitoring/surveillance function of the computerized systems. The complementary and overlapping nature of the safeguards systems is intended to provide multiple layers of safeguards, each layer providing an effective element of protection. Tests to date indicate that it appears feasible to meet operational objectives and maintain a high safeguards performance level using these concepts which are being incorporated into the Advanced Safeguards System.None

  8. Ketone bodies in blood of dairy cows: Prevalence and monitoring of subclinical ketosis

    Directory of Open Access Journals (Sweden)

    Marek Krempaský

    2014-01-01

    Full Text Available The aim of this study was to investigate the relationship between concentration of non-esterified fatty acid and ketone bodies in blood of dairy cows, and to evaluate these concentrations for the detection of prevalence of subclinical ketosis. The second aim was to compare the concentration of β-hydroxybutyric acid determined by an electronic handheld meter Precision Xtra® with serum concentration of β-hydroxybutyric acid analysed in laboratory with izotachometric and photometric method, respectively. Blood samples were collected from jugular vein 4–6 h after morning feeding in three groups of Holstein cows (n = 909 according to the lactation phase from 51 different herds with similar husbandry characteristics. High lipomobilization (non-esterified fatty acid ≥ 0.35 mmol·l-1, mean concentration 0.34 ± 0.15 mmol·l-1 was detected in 30.3% of antepartum cows, while increased concentrations of β-hydroxybutyric acid (≥ 1.0 mmol·l-1, prevalence of subclinical ketosis were detected in 18.5% and 14.1% of the early lactation and mid lactation cows, respectively. The correlation coefficient (r = 0.84, P P ® test and plasma or serum β-hydroxybutyric acid concentration determined by isotachophoresis and photometrical method, respectively. Our results show that the monitoring of changes in the blood concentration of β-hydroxybutyric acid in high-yielding cows in the early postpartum period by the electronic handheld meter Precision Xtra® may be effective in reducing the incidence of ketosis and health problems associated with ketosis in dairy cattle herds.

  9. Strength Measurements in Acute Hamstring Injuries: Intertester Reliability and Prognostic Value of Handheld Dynamometry.

    Science.gov (United States)

    Reurink, Gustaaf; Goudswaard, Gert Jan; Moen, Maarten H; Tol, Johannes L; Verhaar, Jan A N; Weir, Adam

    2016-08-01

    Study Design Cohort study, repeated measures. Background Although hamstring strength measurements are used for assessing prognosis and monitoring recovery after hamstring injury, their actual clinical relevance has not been established. Handheld dynamometry (HHD) is a commonly used method of measuring muscle strength. The reliability of HHD has not been determined in athletes with acute hamstring injuries. Objectives To determine the intertester reliability and the prognostic value of hamstring HHD strength measurement in acute hamstring injuries. Methods We measured knee flexion strength with HHD in 75 athletes at 2 visits, at baseline (within 5 days of hamstring injury) and follow-up (5 to 7 days after the baseline measurement). We assessed isometric hamstring strength in 15° and 90° of knee flexion. Reliability analysis testing was performed by 2 testers independently at the follow-up visit. We recorded the time needed to return to play (RTP) up to 6 months following baseline. Results The intraclass correlation coefficients of the strength measurements in injured hamstrings were between 0.75 and 0.83. There was a statistically significant but weak correlation between the time to RTP and the strength deficit at 15° of knee flexion measured at baseline (Spearman r = 0.25, P = .045) and at the follow-up visit (Spearman r = 0.26, P = .034). Up to 7% of the variance in time to RTP is explained by this strength deficit. None of the other strength variables were significantly correlated with time to RTP. Conclusion Hamstring strength can be reliably measured with HHD in athletes with acute hamstring injuries. The prognostic value of strength measurements is limited, as there is only a weak association between the time to RTP and hamstring strength deficit after acute injury. Level of Evidence Prognosis, level 4. J Orthop Sports Phys Ther 2016;46(8):689-696. Epub 12 May 2016. doi:10.2519/jospt.2016.6363.

  10. Handheld and mobile hyperspectral imaging sensors for wide-area standoff detection of explosives and chemical warfare agents

    Science.gov (United States)

    Gomer, Nathaniel R.; Gardner, Charles W.; Nelson, Matthew P.

    2016-05-01

    Hyperspectral imaging (HSI) is a valuable tool for the investigation and analysis of targets in complex background with a high degree of autonomy. HSI is beneficial for the detection of threat materials on environmental surfaces, where the concentration of the target of interest is often very low and is typically found within complex scenery. Two HSI techniques that have proven to be valuable are Raman and shortwave infrared (SWIR) HSI. Unfortunately, current generation HSI systems have numerous size, weight, and power (SWaP) limitations that make their potential integration onto a handheld or field portable platform difficult. The systems that are field-portable do so by sacrificing system performance, typically by providing an inefficient area search rate, requiring close proximity to the target for screening, and/or eliminating the potential to conduct real-time measurements. To address these shortcomings, ChemImage Sensor Systems (CISS) is developing a variety of wide-field hyperspectral imaging systems. Raman HSI sensors are being developed to overcome two obstacles present in standard Raman detection systems: slow area search rate (due to small laser spot sizes) and lack of eye-safety. SWIR HSI sensors have been integrated into mobile, robot based platforms and handheld variants for the detection of explosives and chemical warfare agents (CWAs). In addition, the fusion of these two technologies into a single system has shown the feasibility of using both techniques concurrently to provide higher probability of detection and lower false alarm rates. This paper will provide background on Raman and SWIR HSI, discuss the applications for these techniques, and provide an overview of novel CISS HSI sensors focused on sensor design and detection results.

  11. Pregnancy in women with Fowler's syndrome treated with sacral neuromodulation.

    Science.gov (United States)

    Khunda, Azar; Karmarkar, Roopali; Abtahi, Bahareh; Gonzales, Gwen; Elneil, Sohier

    2013-07-01

    Our aim was to determine the impact of pregnancy on sacral neuromodulation (SNM) and vice versa in patients with Fowler's syndrome (FS), which is typified by chronic urinary retention (CUR). We performed a retrospective study of pregnancy in patients with FS who underwent a two-stage SNM implantation. Data were obtained using a standard questionnaire and clinical interview. There were a total of ten patients with 13 pregnancies. The SNM was switched off in ten of the 13 pregnancies, with CUR recurring in nine of the ten pregnancies and recurrent urinary tract infections (UTI) occurring in four of these pregnancies (more than three UTI in the pregnancy). Those in whom the device was left on continued to void normally. One woman had a first trimester miscarriage, eight pregnancies went to term, and four deliveries were premature. Caesarean section was performed in eight pregnancies for obstetric reasons. Four pregnancies resulted in a vaginal delivery. There were no congenital anomalies reported. Following delivery, four of nine women experienced dysfunction of their SNM device when it was switched back on. Turing off the SNM during pregnancy results in recurrence of CUR, with an increased risk of recurrent UTI associated with preterm delivery. This did not impact foetal well-being. The option of keeping the SNM on during pregnancy should therefore be considered, and as caesarean section affects the SNM device, we advise that caesarean section should only be performed for obstetric reasons.

  12. Hand-held dynamic visual noise reduces naturally occurring food cravings and craving-related consumption.

    Science.gov (United States)

    Kemps, Eva; Tiggemann, Marika

    2013-09-01

    This study demonstrated the applicability of the well-established laboratory task, dynamic visual noise, as a technique for reducing naturally occurring food cravings and subsequent food intake. Dynamic visual noise was delivered on a hand-held computer device. Its effects were assessed within the context of a diary study. Over a 4-week period, 48 undergraduate women recorded their food cravings and consumption. Following a 2-week baseline, half the participants watched the dynamic visual noise display whenever they experienced a food craving. Compared to a control group, these participants reported less intense cravings. They were also less likely to eat following a craving and consequently consumed fewer total calories following craving. These findings hold promise for curbing unwanted food cravings and craving-driven consumption in real-world settings. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    International Nuclear Information System (INIS)

    Arias, Nestor; Meneses, Nestor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  14. The Complimentary Role of Methoxy-Isobutyl-Isonitrile and Hand-Held Gamma Probe in Adamantinoma

    Science.gov (United States)

    Maharaj, Masha; Korowlay, Nisaar; Ellmann, Prof

    2016-01-01

    Adamantinoma is a rare locally aggressive osteolytic tumor that is found 90% of the time in the diaphysis of the tibia with the remaining lesions found in the fibula and long tubular bones. A case of adamantinoma of the tibia is presented. The added value of nuclear medicine investigations in the workup of this patient is described. A three-phase whole body 99mTc-methylene diphosphonate bone and a whole body 99mTc-methoxy-isobutyl-isonitrile scans were complimentary in the demarcation of viable bone tumor and the assessment of the remainder of the bone and soft tissue to exclude other sites. Intra-operative assistance with a hand-held gamma probe, guided the biopsy of the most metabolically active tumor tissue. Histology revealed a biphasic tumor composed of epithelial and fibrous components, in keeping with an adamantinoma. PMID:26912979

  15. Monitoring/Verification Using DMS: TATP Example

    International Nuclear Information System (INIS)

    Kevin Kyle; Stephan Weeks

    2008-01-01

    Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a 'smart dust' sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the illegal use of explosives or chemical and biological materials. DMS is currently one of the foremost emerging technologies for field separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. GC is the leading analytical method for the separation of chemical species in complex mixtures. Low-thermal-mass GC columns have led to compact, low-power field systems capable of complete analyses in 15-300 seconds. A collaborative effort optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for peroxide-based explosive measurements

  16. Dual Neutral Particle Beam Interrogation of Intermodal Shipping Containers for Special Nuclear Material

    Science.gov (United States)

    Keith, Rodney Lyman

    Intermodal shipping containers entering the United States provide an avenue to smuggle unsecured or stolen special nuclear material (SNM). The only direct method fielded to indicate the presence of SNM is by passive photon/neutron radiation detection. Active interrogation using neutral particle beams to induce fission in SNM is a method under consideration. One by-product of fission is the creation of fragments that undergo radioactive decay over a time period on the order of tens of seconds after the initial event. The "delayed" gamma-rays emitted from these fragments over this period are considered a hallmark for the presence of SNM. A fundamental model is developed using homogenized cargos with a SNM target embedded at the center and computationally interrogated using simultaneous neutron and photon beams. Findings from analysis of the delayed gamma emissions from these experiments are intended to mitigate the effects of poor quality information about the composition and disposition of suspect cargo before examination in an active interrogation portal.

  17. A novel 1050nm handheld OCT imaging system for pediatric retinoblastoma patients: technology development and clinical study (Conference Presentation)

    Science.gov (United States)

    Nadiarnykh, Oleg; Moll, Annette C.; de Boer, Johannes F.

    2016-03-01

    We demonstrate a novel optical coherence tomography system specifically developed and validated for clinical imaging of retinoblastoma tumors in pediatric patients. The existing treatment options for this malignant tumor of the retina aim at reduction of tumor (re)growth risks, and vision preservation. The choice of optimal treatment strongly depends on skilled and detailed clinical assessment. Due to the limitations of the existing real-time diagnostic tools the patients at risk are periodically monitored with retinal imaging to confirm the absence of new tumor seedings. Three-dimensional visualization of tissue layer and microvasculature at improved axial and lateral resolution of interference-based OCT imaging provides sensitivity for detection of vital tumor tissue concurrent with local treatment. Our METC-approved system accommodates for the range of optical parameters of infants' eyes, and uses the 1050nm wavelength to access the deeper choroid layers of retina. The prototype is designed for patients in supine position under general anesthesia, where ergonomic handheld module is connected to fiber-based optical setup via umbilical cord. The system conforms to clinical safety requirements, including fully isolated low-voltage electric circuit. Focusing is performed with a mechanically tunable lens, where resolution is 6 µm axially, and varies with focusing at 10-18µm laterally. We will present optical design, performance limitations, and results of the ongoing clinical study, including the increased OCT diagnostic sensitivity in three dimensions in comparison with the established clinical imaging modalities. We will discuss images of early, active, and treated tumors, as well as follow-up on patients after local and systemic treatments.

  18. Detecting special nuclear material using muon-induced neutron emission

    Energy Technology Data Exchange (ETDEWEB)

    Guardincerri, Elena; Bacon, Jeffrey; Borozdin, Konstantin; Matthew Durham, J.; Fabritius II, Joseph [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Hecht, Adam [University of New Mexico, Albuquerque, NM 87131 (United States); Milner, Edward C. [Southern Methodist University, Dallas, TX 75205 (United States); Miyadera, Haruo; Morris, Christopher L. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Perry, John [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); University of New Mexico, Albuquerque, NM 87131 (United States); Poulson, Daniel [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States)

    2015-07-21

    The penetrating ability of cosmic ray muons makes them an attractive probe for imaging dense materials. Here, we describe experimental results from a new technique that uses neutrons generated by cosmic-ray muons to identify the presence of special nuclear material (SNM). Neutrons emitted from SNM are used to tag muon-induced fission events in actinides and laminography is used to form images of the stopping material. This technique allows the imaging of SNM-bearing objects tagged using muon tracking detectors located above or to the side of the objects, and may have potential applications in warhead verification scenarios. During the experiment described here we did not attempt to distinguish the type or grade of the SNM.

  19. Biochip for Real-Time Monitoring of Hepatitis B Virus (HBV) by Combined Loop-Mediated Isothermal Amplification and Solution-Phase Electrochemical Detection

    Science.gov (United States)

    Tien, Bui Quang; Ngoc, Nguyen Thy; Loc, Nguyen Thai; Thu, Vu Thi; Lam, Tran Dai

    2017-06-01

    Accurate in situ diagnostic tests play a key role in patient management and control of most infectious diseases. To achieve this, use of handheld biochips that implement sample handling, sample analysis, and result readout together is an ideal approach. We present herein a fluid-handling biochip for real-time electrochemical monitoring of nucleic acid amplification based on loop-mediated isothermal amplification and real-time electrochemical detection on a microfluidic platform. Intercalation between amplifying DNA and free redox probe in solution phase was used to monitor the number of DNA copies. The whole diagnostic process is completed within 70 min. Our platform offers a fast and easy tool for quantification of viral pathogens in shorter time and with limited risk of all potential forms of cross-contamination. Such diagnostic tools have potential to make a huge difference to the lives of millions of people worldwide.

  20. Handheld echocardiography during hospitalization for acute myocardial infarction.

    Science.gov (United States)

    Cullen, Michael W; Geske, Jeffrey B; Anavekar, Nandan S; Askew, J Wells; Lewis, Bradley R; Oh, Jae K

    2017-11-01

    Handheld echocardiography (HHE) is concordant with standard transthoracic echocardiography (TTE) in a variety of settings but has not been thoroughly compared to traditional TTE in patients with acute myocardial infarction (AMI). Completed by experienced operators, HHE provides accurate diagnostic capabilities compared with standard TTE in AMI patients. This study prospectively enrolled patients admitted to the coronary care unit with AMI. Experienced sonographers performed HHE with a V-scan. All patients underwent clinical TTE. Each HHE was interpreted by 2 experts blinded to standard TTE. Agreement was assessed with κ statistics and concordance correlation coefficients. Analysis included 82 patients (mean age, 66 years; 74% male). On standard TTE, mean left ventricular (LV) ejection fraction was 46%. Correlation coefficients between HHE and TTE were 0.75 (95% confidence interval: 0.66 to 0.82) for LV ejection fraction and 0.69 (95% confidence interval: 0.58 to 0.77) for wall motion score index. The κ statistics ranged from 0.47 to 0.56 for LV enlargement, 0.55 to 0.79 for mitral regurgitation, and 0.44 to 0.57 for inferior vena cava dilatation. The κ statistics were highest for the anterior (0.81) and septal (0.71) apex and lowest for the mid inferolateral (0.36) and basal inferoseptal (0.36) walls. In patients with AMI, HHE and standard TTE demonstrate good correlation for LV function and wall motion. Agreement was less robust for structural abnormalities and specific wall segments. In experienced hands, HHE can provide a focused assessment of LV function in patients hospitalized with AMI; however, HHE should not substitute for comprehensive TTE. © 2017 Wiley Periodicals, Inc.

  1. Monitoring engineering structures by the comparison of similar photographs

    International Nuclear Information System (INIS)

    Jones, A.

    1976-12-01

    A commonly used method of monitoring engineering structures is to compare similar photographs taken at different times. The initial part of this note deals with commercially available equipment, known as a comparascope, which enables differences between photographs to be rapidly (and reliably) detected. A series of practical tests is described in which it is established that a change in dimensions of 0.05mm can be detected between photographs. For typical camera systems, this will usually correspond to detectable displacements of the order of several mm in object space. Perhaps the most serious disadvantages of the technique is that alterations in camera attitude between photographs can cause changes in the recorded image which mask genuine movements in the structure. The changes caused by a given shift in camera attitude are, therefore, investigated theoretically. Since it is desirable that the changes are small enough to go undetected in the comparison, the established detection limit of the comparascope is included in the investigation to specify how accurately the camera attitude must be controlled for a given set of experimental circumstances. As a result, it appears that a special purpose camera mounting will nearly always be required if structural differences as small as several mm are to be reliably detected. Hand-held cameras should only be used for relatively coarse monitoring tasks. (author)

  2. Into the Wild: Neuroergonomic Differentiation of Hand-Held and Augmented Reality Wearable Displays during Outdoor Navigation with Functional Near Infrared Spectroscopy.

    Science.gov (United States)

    McKendrick, Ryan; Parasuraman, Raja; Murtza, Rabia; Formwalt, Alice; Baccus, Wendy; Paczynski, Martin; Ayaz, Hasan

    2016-01-01

    Highly mobile computing devices promise to improve quality of life, productivity, and performance. Increased situation awareness and reduced mental workload are two potential means by which this can be accomplished. However, it is difficult to measure these concepts in the "wild". We employed ultra-portable battery operated and wireless functional near infrared spectroscopy (fNIRS) to non-invasively measure hemodynamic changes in the brain's Prefrontal cortex (PFC). Measurements were taken during navigation of a college campus with either a hand-held display, or an Augmented reality wearable display (ARWD). Hemodynamic measures were also paired with secondary tasks of visual perception and auditory working memory to provide behavioral assessment of situation awareness and mental workload. Navigating with an augmented reality wearable display produced the least workload during the auditory working memory task, and a trend for improved situation awareness in our measures of prefrontal hemodynamics. The hemodynamics associated with errors were also different between the two devices. Errors with an augmented reality wearable display were associated with increased prefrontal activity and the opposite was observed for the hand-held display. This suggests that the cognitive mechanisms underlying errors between the two devices differ. These findings show fNIRS is a valuable tool for assessing new technology in ecologically valid settings and that ARWDs offer benefits with regards to mental workload while navigating, and potentially superior situation awareness with improved display design.

  3. A multisite randomized trial of social norms marketing campaigns to reduce college student drinking.

    Science.gov (United States)

    DeJong, William; Schneider, Shari Kessel; Towvim, Laura Gomberg; Murphy, Melissa J; Doerr, Emily E; Simonsen, Neal R; Mason, Karen E; Scribner, Richard A

    2006-11-01

    An 18-site randomized trial was conducted to determine the effectiveness of social norms marketing (SNM) campaigns in reducing college student drinking. The SNM campaigns are intended to correct misperceptions of subjective drinking norms and thereby drive down alcohol consumption. Institutions of higher education were randomly assigned to treatment and control groups. At the treatment group institutions, SNM campaigns delivered school-specific, data-driven messages through a mix of campus media venues. Cross-sectional student surveys were conducted by mail at baseline (n = 2,771) and at posttest 3 years later (n = 2,939). Hierarchical linear modeling was applied to examine multiple drinking outcomes, taking intraclass correlation into account. Controlling for other predictors, having an SNM campaign was significantly associated with lower perceptions of student drinking levels and lower alcohol consumption, as measured by a composite drinking scale, recent maximum consumption, blood alcohol concentration for recent maximum consumption, drinks consumed when partying, and drinks consumed per week. A moderate mediating effect of normative perceptions on student drinking was demonstrated by an attenuation of the Experimental Group x Time interaction, ranging from 16.4% to 39.5% across measures. Additional models that took into account the intensity of SNM campaign activity at the treatment institutions suggested that there was a dose-response relationship. This study is the most rigorous evaluation of SNM campaigns conducted to date. Analysis revealed that students attending institutions that implemented an SNM campaign had a lower relative risk of alcohol consumption than students attending control group institutions.

  4. Mobile Carbon Monoxide Monitoring System Based on Arduino-Matlab for Environmental Monitoring Application

    Science.gov (United States)

    Azieda Mohd Bakri, Nur; Junid, Syed Abdul Mutalib Al; Razak, Abdul Hadi Abdul; Idros, Mohd Faizul Md; Karimi Halim, Abdul

    2015-11-01

    Nowadays, the increasing level of carbon monoxide globally has become a serious environmental issue which has been highlighted in most of the country globally. The monitoring of carbon monoxide content is one of the approaches to identify the level of carbon monoxide pollution towards providing the solution for control the level of carbon monoxide produced. Thus, this paper proposed a mobile carbon monoxide monitoring system for measuring the carbon monoxide content based on Arduino-Matlab General User Interface (GUI). The objective of this project is to design, develop and implement the real-time mobile carbon monoxide sensor system and interfacing for measuring the level of carbon monoxide contamination in real environment. Four phases or stages of work have been carried out for the accomplishment of the project, which classified as sensor development, controlling and integrating sensor, data collection and data analysis. As a result, a complete design and developed system has been verified with the handheld industrial standard carbon monoxide sensor for calibrating the sensor sensitivity and measurement in the laboratory. Moreover, the system has been tested in real environments by measuring the level of carbon monoxide in three different lands used location; industrial area; residential area and main road (commercial area). In this real environment test, the industrial area recorded the highest reading with 71.23 ppm and 82.59 ppm for sensor 1 and sensor 2 respectively. As a conclusion, the mobile realtime carbon monoxide system based on the Arduino-Matlab is the best approach to measure the carbon monoxide concentration in different land-used since it does not require a manual data collection and reduce the complexity of the existing carbon monoxide level concentration measurement practise at the same time with a complete data analysis facilities.

  5. An Enhanced Intelligent Handheld Instrument with Visual Servo Control for 2-DOF Hand Motion Error Compensation

    Directory of Open Access Journals (Sweden)

    Yan Naing Aye

    2013-10-01

    Full Text Available The intelligent handheld instrument, ITrem2, enhances manual positioning accuracy by cancelling erroneous hand movements and, at the same time, provides automatic micromanipulation functions. Visual data is acquired from a high speed monovision camera attached to the optical surgical microscope and acceleration measurements are acquired from the inertial measurement unit (IMU on board ITrem2. Tremor estimation and canceling is implemented via Band-limited Multiple Fourier Linear Combiner (BMFLC filter. The piezoelectric actuated micromanipulator in ITrem2 generates the 3D motion to compensate erroneous hand motion. Preliminary bench-top 2-DOF experiments have been conducted. The error motions simulated by a motion stage is reduced by 67% for multiple frequency oscillatory motions and 56.16% for pre-conditioned recorded physiological tremor.

  6. Elemental Analysis of Bone, Teeth, Horn and Antler in Different Animal Species Using Non-Invasive Handheld X-Ray Fluorescence

    Science.gov (United States)

    Buddhachat, Kittisak; Klinhom, Sarisa; Siengdee, Puntita; Brown, Janine L.; Nomsiri, Raksiri; Kaewmong, Patcharaporn; Thitaram, Chatchote; Mahakkanukrauh, Pasuk; Nganvongpanit, Korakot

    2016-01-01

    Mineralized tissues accumulate elements that play crucial roles in animal health. Although elemental content of bone, blood and teeth of human and some animal species have been characterized, data for many others are lacking, as well as species comparisons. Here we describe the distribution of elements in horn (Bovidae), antler (Cervidae), teeth and bone (humerus) across a number of species determined by handheld X-ray fluorescence (XRF) to better understand differences and potential biological relevance. A difference in elemental profiles between horns and antlers was observed, possibly due to the outer layer of horns being comprised of keratin, whereas antlers are true bone. Species differences in tissue elemental content may be intrinsic, but also related to feeding habits that contribute to mineral accumulation, particularly for toxic heavy metals. One significant finding was a higher level of iron (Fe) in the humerus bone of elephants compared to other species. This may be an adaptation of the hematopoietic system by distributing Fe throughout the bone rather than the marrow, as elephant humerus lacks a marrow cavity. We also conducted discriminant analysis and found XRF was capable of distinguishing samples from different species, with humerus bone being the best source for species discrimination. For example, we found a 79.2% correct prediction and success rate of 80% for classification between human and non-human humerus bone. These findings show that handheld XRF can serve as an effective tool for the biological study of elemental composition in mineralized tissue samples and may have a forensic application. PMID:27196603

  7. Elemental Analysis of Bone, Teeth, Horn and Antler in Different Animal Species Using Non-Invasive Handheld X-Ray Fluorescence.

    Directory of Open Access Journals (Sweden)

    Kittisak Buddhachat

    Full Text Available Mineralized tissues accumulate elements that play crucial roles in animal health. Although elemental content of bone, blood and teeth of human and some animal species have been characterized, data for many others are lacking, as well as species comparisons. Here we describe the distribution of elements in horn (Bovidae, antler (Cervidae, teeth and bone (humerus across a number of species determined by handheld X-ray fluorescence (XRF to better understand differences and potential biological relevance. A difference in elemental profiles between horns and antlers was observed, possibly due to the outer layer of horns being comprised of keratin, whereas antlers are true bone. Species differences in tissue elemental content may be intrinsic, but also related to feeding habits that contribute to mineral accumulation, particularly for toxic heavy metals. One significant finding was a higher level of iron (Fe in the humerus bone of elephants compared to other species. This may be an adaptation of the hematopoietic system by distributing Fe throughout the bone rather than the marrow, as elephant humerus lacks a marrow cavity. We also conducted discriminant analysis and found XRF was capable of distinguishing samples from different species, with humerus bone being the best source for species discrimination. For example, we found a 79.2% correct prediction and success rate of 80% for classification between human and non-human humerus bone. These findings show that handheld XRF can serve as an effective tool for the biological study of elemental composition in mineralized tissue samples and may have a forensic application.

  8. Elemental Analysis of Bone, Teeth, Horn and Antler in Different Animal Species Using Non-Invasive Handheld X-Ray Fluorescence.

    Science.gov (United States)

    Buddhachat, Kittisak; Klinhom, Sarisa; Siengdee, Puntita; Brown, Janine L; Nomsiri, Raksiri; Kaewmong, Patcharaporn; Thitaram, Chatchote; Mahakkanukrauh, Pasuk; Nganvongpanit, Korakot

    2016-01-01

    Mineralized tissues accumulate elements that play crucial roles in animal health. Although elemental content of bone, blood and teeth of human and some animal species have been characterized, data for many others are lacking, as well as species comparisons. Here we describe the distribution of elements in horn (Bovidae), antler (Cervidae), teeth and bone (humerus) across a number of species determined by handheld X-ray fluorescence (XRF) to better understand differences and potential biological relevance. A difference in elemental profiles between horns and antlers was observed, possibly due to the outer layer of horns being comprised of keratin, whereas antlers are true bone. Species differences in tissue elemental content may be intrinsic, but also related to feeding habits that contribute to mineral accumulation, particularly for toxic heavy metals. One significant finding was a higher level of iron (Fe) in the humerus bone of elephants compared to other species. This may be an adaptation of the hematopoietic system by distributing Fe throughout the bone rather than the marrow, as elephant humerus lacks a marrow cavity. We also conducted discriminant analysis and found XRF was capable of distinguishing samples from different species, with humerus bone being the best source for species discrimination. For example, we found a 79.2% correct prediction and success rate of 80% for classification between human and non-human humerus bone. These findings show that handheld XRF can serve as an effective tool for the biological study of elemental composition in mineralized tissue samples and may have a forensic application.

  9. Calculation of induced current densities and specific absorption rates (SAR) for pregnant women exposed to hand-held metal detectors

    International Nuclear Information System (INIS)

    Kainz, Wolfgang; Chan, Dulciana D; Casamento, Jon P; Bassen, Howard I

    2003-01-01

    The finite difference time domain (FDTD) method in combination with a well established frequency scaling method was used to calculate the internal fields and current densities induced in a simple model of a pregnant woman and her foetus, when exposed to hand-held metal detectors. The pregnant woman and foetus were modelled using a simple semi-heterogeneous model in 10 mm resolution, consisting of three different types of tissue. The model is based on the scanned shape of a pregnant woman in the 34th gestational week. Nine different representative models of hand-held metal detectors operating in the frequency range from 8 kHz to 2 MHz were evaluated. The metal detectors were placed directly on the abdomen of the computational model with a spacing of 1 cm. Both the induced current density and the specific absorption rate (SAR) are well below the recommended limits for exposure of the general public published in the ICNIRP Guidelines and the IEEE C95.1 Standard. The highest current density is 8.3 mA m -2 and the highest SAR is 26.5 μW kg -1 . Compared to the limits for the induced current density recommended in the ICNIRP Guidelines, a minimum safety factor of 3 exists. Compared to the IEEE C95.1 Standard, a safety factor of 60,000 for the specific absorption rate was found. Based on the very low specific absorption rate and an induced current density below the recommended exposure limits, significant temperature rise or nerve stimulation in the pregnant woman or in the foetus can be excluded

  10. Operational facility-integrated computer system for safeguards

    International Nuclear Information System (INIS)

    Armento, W.J.; Brooksbank, R.E.; Krichinsky, A.M.

    1980-01-01

    A computer system for safeguards in an active, remotely operated, nuclear fuel processing pilot plant has been developed. This sytem maintains (1) comprehensive records of special nuclear materials, (2) automatically updated book inventory files, (3) material transfer catalogs, (4) timely inventory estimations, (5) sample transactions, (6) automatic, on-line volume balances and alarmings, and (7) terminal access and applications software monitoring and logging. Future development will include near-real-time SNM mass balancing as both a static, in-tank summation and a dynamic, in-line determination. It is planned to incorporate aspects of site security and physical protection into the computer monitoring

  11. Hand-held multi-DOF robotic forceps for neurosurgery designed for dexterous manipulation in deep and narrow space.

    Science.gov (United States)

    Okubo, Takuro; Harada, Kanako; Fujii, Masahiro; Tanaka, Shinichi; Ishimaru, Tetsuya; Iwanaka, Tadashi; Nakatomi, Hirohumi; Sora, Sigeo; Morita, Akio; Sugita, Naohiko; Mitsuishi, Mamoru

    2014-01-01

    Neurosurgical procedures require precise and dexterous manipulation of a surgical suture in narrow and deep spaces in the brain. This is necessary for surgical tasks such as the anastomosis of microscopic blood vessels and dura mater suturing. A hand-held multi-degree of freedom (DOF) robotic forceps was developed to aid the performance of such difficult tasks. The diameter of the developed robotic forceps is 3.5 mm, and its tip has three DOFs, namely, bending, rotation, and grip. Experimental results showed that the robotic forceps had an average needle insertion force of 1.7 N. Therefore, an increase in the needle insertion force is necessary for practical application of the developed device.

  12. Characterization of wood dust emission from hand-held woodworking machines.

    Science.gov (United States)

    Keller, F-X; Chata, F

    2018-01-01

    This article focuses on the prevention of exposure to wood dust when operating electrical hand-held sawing and sanding machines. A laboratory methodology was developed to measure the dust concentration around machines during operating processes. The main objective was to characterize circular saws and sanders, with the aim of classifying the different power tools tested in terms of dust emission (high dust emitter vs. low dust emitter). A test set-up was developed and is described and a measurement methodology was determined for each of the two operations studied. The robustness of the experimental results is discussed and shows good tendencies. The impact of air-flow extraction rate was assessed and the pressure loss of the system for each machine established. For the circular saws, three machines over the nine tested could be classified in the low dust emitter group. Their mean concentration values measured are between 0.64 and 0.98 mg/m 3 for the low dust emitter group and from 2.55 and 4.37 mg/m 3 for the high dust emitter group. From concentration measurements, a machine classification is possible-one for sanding machines and one for sawing machines-and a ratio from 1-7 is obtained when comparing the results. This classification will be helpful when a choice of high performance power tools, in terms of dust emission, must be made by professionals.

  13. Accuracy of Mobile Phone and Handheld Light Microscopy for the Diagnosis of Schistosomiasis and Intestinal Protozoa Infections in Côte d'Ivoire.

    Directory of Open Access Journals (Sweden)

    Jean T Coulibaly

    2016-06-01

    Full Text Available Handheld light microscopy using compact optics and mobile phones may improve the quality of health care in resource-constrained settings by enabling access to prompt and accurate diagnosis.Laboratory technicians were trained to operate two handheld diagnostic devices (Newton Nm1 microscope and a clip-on version of the mobile phone-based CellScope. The accuracy of these devices was compared to conventional light microscopy for the diagnosis of Schistosoma haematobium, S. mansoni, and intestinal protozoa infection in a community-based survey in rural Côte d'Ivoire. One slide of 10 ml filtered urine and a single Kato-Katz thick smear from 226 individuals were subjected to the Newton Nm1 microscope and CellScope for detection of Schistosoma eggs and compared to conventional microscopy. Additionally, 121 sodium acetate-acetic acid-formalin (SAF-fixed stool samples were examined by the Newton Nm1 microscope and compared to conventional microscopy for the diagnosis of intestinal protozoa.The prevalence of S. haematobium, S. mansoni, Giardia intestinalis, and Entamoeba histolytica/E. dispar, as determined by conventional microscopy, was 39.8%, 5.3%, 20.7%, and 4.9%, respectively. The Newton Nm1 microscope had diagnostic sensitivities for S. mansoni and S. haematobium infection of 91.7% (95% confidence interval (CI 59.8-99.6% and 81.1% (95% CI 71.2-88.3%, respectively, and specificities of 99.5% (95% CI 97.0-100% and 97.1% (95% CI 92.2-99.1%, respectively. The CellScope demonstrated sensitivities for S. mansoni and S. haematobium of 50.0% (95% CI 25.4-74.6% and 35.6% (95% CI 25.9-46.4%, respectively, and specificities of 99.5% (95% CI 97.0-100% and 100% (95% CI 86.7-100%, respectively. For G. intestinalis and E. histolytica/E. dispar, the Newton Nm1 microscope had sensitivity of 84.0% (95% CI 63.1-94.7% and 83.3% (95% CI 36.5-99.1%, respectively, and 100% specificity.Handheld diagnostic devices can be employed in community-based surveys in resource

  14. Accuracy of Mobile Phone and Handheld Light Microscopy for the Diagnosis of Schistosomiasis and Intestinal Protozoa Infections in Côte d'Ivoire.

    Science.gov (United States)

    Coulibaly, Jean T; Ouattara, Mamadou; D'Ambrosio, Michael V; Fletcher, Daniel A; Keiser, Jennifer; Utzinger, Jürg; N'Goran, Eliézer K; Andrews, Jason R; Bogoch, Isaac I

    2016-06-01

    Handheld light microscopy using compact optics and mobile phones may improve the quality of health care in resource-constrained settings by enabling access to prompt and accurate diagnosis. Laboratory technicians were trained to operate two handheld diagnostic devices (Newton Nm1 microscope and a clip-on version of the mobile phone-based CellScope). The accuracy of these devices was compared to conventional light microscopy for the diagnosis of Schistosoma haematobium, S. mansoni, and intestinal protozoa infection in a community-based survey in rural Côte d'Ivoire. One slide of 10 ml filtered urine and a single Kato-Katz thick smear from 226 individuals were subjected to the Newton Nm1 microscope and CellScope for detection of Schistosoma eggs and compared to conventional microscopy. Additionally, 121 sodium acetate-acetic acid-formalin (SAF)-fixed stool samples were examined by the Newton Nm1 microscope and compared to conventional microscopy for the diagnosis of intestinal protozoa. The prevalence of S. haematobium, S. mansoni, Giardia intestinalis, and Entamoeba histolytica/E. dispar, as determined by conventional microscopy, was 39.8%, 5.3%, 20.7%, and 4.9%, respectively. The Newton Nm1 microscope had diagnostic sensitivities for S. mansoni and S. haematobium infection of 91.7% (95% confidence interval (CI) 59.8-99.6%) and 81.1% (95% CI 71.2-88.3%), respectively, and specificities of 99.5% (95% CI 97.0-100%) and 97.1% (95% CI 92.2-99.1%), respectively. The CellScope demonstrated sensitivities for S. mansoni and S. haematobium of 50.0% (95% CI 25.4-74.6%) and 35.6% (95% CI 25.9-46.4%), respectively, and specificities of 99.5% (95% CI 97.0-100%) and 100% (95% CI 86.7-100%), respectively. For G. intestinalis and E. histolytica/E. dispar, the Newton Nm1 microscope had sensitivity of 84.0% (95% CI 63.1-94.7%) and 83.3% (95% CI 36.5-99.1%), respectively, and 100% specificity. Handheld diagnostic devices can be employed in community-based surveys in resource

  15. Fast monitoring of indoor bioaerosol concentrations with ATP bioluminescence assay using an electrostatic rod-type sampler.

    Directory of Open Access Journals (Sweden)

    Ji-Woon Park

    Full Text Available A culture-based colony counting method is the most widely used analytical technique for monitoring bioaerosols in both indoor and outdoor environments. However, this method requires several days for colony formation. In this study, our goal was fast monitoring (Sampling: 3 min, Detection: < 1 min of indoor bioaerosol concentrations with ATP bioluminescence assay using a bioaerosol sampler. For this purpose, a novel hand-held electrostatic rod-type sampler (110 mm wide, 115 mm long, and 200 mm tall was developed and used with a commercial luminometer, which employs the Adenosine triphosphate (ATP bioluminescence method. The sampler consisted of a wire-rod type charger and a cylindrical collector, and was operated with an applied voltage of 4.5 kV and a sampling flow rate of 150.7 lpm. Its performance was tested using Staphylococcus epidermidis which was aerosolized with an atomizer. Bioaerosol concentrations were measured using ATP bioluminescence method with our sampler and compared with the culture-based method using Andersen cascade impactor under controlled laboratory conditions. Indoor bioaerosol concentrations were also measured using both methods in various indoor environments. A linear correlation was obtained between both methods in lab-tests and field-tests. Our proposed sampler with ATP bioluminescence method may be effective for fast monitoring of indoor bioaerosol concentrations.

  16. Reliability of hand-held dynamometry for measurement of lower limb muscle strength in children with Duchenne and Becker muscular dystrophy

    Directory of Open Access Journals (Sweden)

    Wei SHI

    2015-05-01

    Full Text Available Objective To determine the reliability of hand-held dynamometry (HHD for lower limb isometric muscle strength measurement in children with Duchenne and Becker muscular dystrophy (DMD/BMD.  Methods A total of 21 children [20 males and one female; mean age was (7.88 ± 2.87 years, ranging between 3.96-14.09 years; mean age at diagnosis was (5.88 ± 2.88 years, ranging between 1.35-12.89 years; mean height was (120.64 ± 16.30 cm, ranging between 97-153 cm; mean body weight was (24.62 ± 9.05 kg, ranging between 14-50 kg] with DMD (19/21 and BMD (2/21 were involved from Rehabilitation Center of Children's Hospital of Fudan University. The muscle strength of hip, knee and ankle was measured by HHD under standardized test methods. The test-retest results were compared to determine the inter-test reliability, and the results among testers were compared to determine the inter-tester reliability.  Results HHD showed fine inter-tester reliability (ICC = 0.762-0.978 and inter-test reliability (ICC = 0.690-0.938 in measuring lower limb muscle strength of children with DMD/BMD. Results also showed relatively poor reliability in distal muscle groups (foot plantar flexion and dorsiflexion.  Conclusions HHD, showing fine inter-tester and inter-test reliability in measuring the lower limb muscle strength of children with DMD/BMD, can be used in monitoring muscle strength changing and assessing effects of clinical interventions. DOI: 10.3969/j.issn.1672-6731.2015.05.009

  17. Development and implementation of attractiveness Level E criteria and the plutonium disposition methodology

    International Nuclear Information System (INIS)

    Christensen, D.C.; Robinson, M.A.

    1998-03-01

    Historically, the Department of Energy used the Economic Discard Limits (EDLs), those Special Nuclear Material (SNM) concentrations in residue matrices below which production of new SNM was more economic than SNM recovery, as a basis for discard decisions. In 1994, a joint team from DOE Defense Programs (DP) and Environmental Management (EM) determined that the EDLs were no longer a valid discriminator and directed that SNM disposition consider instead 12 specific criteria, foremost of which are waste minimization, environmental impacts, safety, proliferation concerns, and cost. In response, the Los Alamos National Laboratory developed a technical basis for determining SNM bearing materials unattractive for proliferation purposes and a quantitative method for predicting materials disposition consequences as a basis for decision making called the plutonium disposition methodology. The objective of attractiveness Level E criteria is to insure that waste is unattractive for proliferation or terrorist purposes. Level E criteria is about 0.17 kg Pu per 208 liter drum (requiring diversion of a minimum of 54 drums, assuming 100% recovery efficiency)

  18. Neonatal Morbidity at Term, Early Child Development, and School Performance: A Population Study.

    Science.gov (United States)

    Bentley, Jason P; Schneuer, Francisco J; Lain, Samantha J; Martin, Andrew J; Gordon, Adrienne; Nassar, Natasha

    2018-02-01

    Investigate the association between severe neonatal morbidity (SNM) and child development and school performance among term infants. The study population included term infants without major congenital conditions born between 2000 and 2007 in New South Wales, Australia, with a linked record of developmental assessment at ages 4 to 6 years in 2009 or 2012 ( n = 144 535) or school performance at ages 7 to 9 years from 2009 to 2014 ( n = 253 447). Developmental outcomes included special needs or being vulnerable and/or at risk in 1 of 5 developmental domains. School performance outcomes were test exemption, or performing <-1 SD on reading or numeracy tests. Binary generalized estimating equations were used to estimate associations between SNM and outcomes, adjusting for sociodemographic, perinatal, and assessment and/or test characteristics. Overall, 2.1% of infants experienced SNM. The adjusted odds ratio (95% confidence interval) for SNM and physical health was 1.18 (1.08-1.29), 1.14 (1.02-1.26) for language and cognitive skills, and 1.14 (1.06-1.24) and 1.13 (1.05-1.21) for scoring <-1 SD in reading and numeracy, respectively. SNM was most strongly associated with special needs 1.34 (1.15-1.55) and test exemption 1.50 (1.25-1.81). SNM infants born at 37 to 38 weeks' gestation and who were small for gestational age had the greatest likelihood of poorer outcomes. Term infants with SNM have greater odds of poor neurodevelopment in childhood. These findings provide population-based information for families and can inform clinical counseling and guidelines for follow-up and early intervention. Copyright © 2018 by the American Academy of Pediatrics.

  19. Hazardous metals in vintage plastic toys measured by a handheld X-ray fluorescence spectrometer.

    Science.gov (United States)

    Miller, Gillian Zaharias; Harris, Zoe E

    2015-01-01

    Over 100 plastic toys from the 1970s and 1980s, both polyvinyl chloride ("vinyl") and nonvinyl, were analyzed in the study described here using a handheld X-ray fluorescence spectrometer to quantify hazardous metal content. A sampling of recent vinyl toys was also tested. The majority of nonvinyl samples were Fisher Price brand toys. The vinyl toys consisted largely of Barbie dolls and other dolls. Overall, lead or cadmium was found in 67% of vintage plastic toys, frequently at concentrations exceeding current U.S. and European limits. Arsenic was detected at levels of concern in 16% of the samples. In the nonvinyl toys, heavy metal content was found to correlate with certain colors of plastic. The likely sources of the detected metals are discussed. None of the contemporary vinyl toys contained detectable cadmium, lead, or arsenic. Given that vintage toys remain in widespread use by children in homes and other locations, the results illuminate a potential source of heavy metal exposure for children.

  20. DRIVING SUSTAINABLE INNOVATION IN CONSTRUCTION COMPANIES

    DEFF Research Database (Denmark)

    Thuesen, Christian Langhoff; Koch, Christian

    2011-01-01

    By adopting a theoretical framework from strategic niche management research (SNM) this paper presents an analysis of the innovation system of the Danish Construction industry. Theories within SNM look upon innovation in a sector as a socio-technical phenomenon and identify three levels of socio...... for innovation in the construction industry. By bridging SNM with business development activities through an adapted version of Ansoffs growth matrix, companies continuously and consciously can develop a competitive advantage by targeting new and existing markets with new or existing competencies...

  1. Westinghouse Hanford Company special nuclear material vault storage study

    International Nuclear Information System (INIS)

    Borisch, R.R.

    1996-01-01

    Category 1 and 2 Special Nuclear Materials (SNM) require storage in vault or vault type rooms as specified in DOE orders 5633.3A and 6430.1A. All category 1 and 2 SNM in dry storage on the Hanford site that is managed by Westinghouse Hanford Co (WHC) is located in the 200 West Area at Plutonium Finishing Plant (PFP) facilities. This document provides current and projected SNM vault inventories in terms of storage space filled and forecasts available space for possible future storage needs

  2. Duplication of complete dentures using general-purpose handheld optical scanner and 3-dimensional printer: Introduction and clinical considerations.

    Science.gov (United States)

    Kurahashi, Kosuke; Matsuda, Takashi; Goto, Takaharu; Ishida, Yuichi; Ito, Teruaki; Ichikawa, Tetsuo

    2017-01-01

    To introduce a new clinical procedure for fabricating duplicates of complete dentures by bite pressure impression using digital technology, and to discuss its clinical significance. The denture is placed on a rotary table and the 3-dimensional form of the denture is digitized using a general-purpose handheld optical scanner. The duplicate denture is made of polylactic acid by a 3-dimensional printer using the 3-dimensional data. This procedure has the advantages of wasting less material, employing less human power, decreasing treatment time at the chair side, lowering the rates of contamination, and being readily fabricated at the time of the treatment visit. Copyright © 2016 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. Initial experience with a handheld device digital imaging and communications in medicine viewer: OsiriX mobile on the iPhone.

    Science.gov (United States)

    Choudhri, Asim F; Radvany, Martin G

    2011-04-01

    Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility of mobile review of diagnostic medical images to expedite diagnosis and treatment planning using a commercial off the shelf solution, facilitating communication among radiologists and referring clinicians.

  4. A handheld low temperature atmospheric pressure air plasma gun for nanomaterial synthesis in liquid phase

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Shuang; Wang, Kaile; Zuo, Shasha; Liu, Jiahui [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); Zhang, Jue, E-mail: zhangjue@pku.edu.cn; Fang, Jing [Academy for Advanced Interdisciplinary Studies, Peking University, Beijing 100871 (China); College of Engineering, Peking University, Beijing 100871 (China)

    2015-10-15

    A handheld low temperature atmospheric pressure air plasma gun based on a dielectric barrier structure with hollow electrodes was proposed. The portable plasma gun with an embedded mini air pump was driven by a 12 V direct voltage battery. The air plasma jet generated from the gun could be touched without a common shock hazard. Besides working in air, the plasma gun can also work in water. The diagnostic result of optical emission spectroscopy showed the difference in reactive species of air plasma jet between in air and in water. The plasma gun was excited in 20 ml chloroauric acid aqueous solution with a concentration of 1.214 mM. A significant amount of gold nanoparticles were synthesized after 2 min continuous discharge. The plasma gun with these unique features is applicable in plasma medicine, etching, and s-nthesis of nanomaterials.

  5. Mobile applications for handheld devices to screen and randomize acute stroke patients in clinical trials.

    Science.gov (United States)

    Qureshi, Ai; Connelly, B; Abbott, Ei; Maland, E; Kim, J; Blake, J

    2012-08-01

    The availability of internet connectivity and mobile application software used by low-power handheld devices makes smart phones of unique value in time-sensitive clinical trials. Trial-specific applications can be downloaded by investigators from various mobile software distribution platforms or web applications delivered over HTTP. The Antihypertensive Treatment in Acute Cerebral Hemorrhage (ATACH) II investigators in collaboration with MentorMate released the ATACH-II Patient Recruitment mobile application available on iPhone, Android, and Blackberry in 2011. The mobile application provides tools for pre-screening, assessment of eligibility, and randomization of patients. Since the release of ATACH-II mobile application, the CLEAR-IVH (Clot Lysis Evaluating Accelerated Resolution of Intraventricular Hemorrhage) trial investigators have also adopted such a mobile application. The video-conferencing capabilities of the most recent mobile devices open up additional opportunities to involve central coordinating centers in the recruitment process in real time.

  6. In situ, dual-mode monitoring of organ-on-a-chip with smartphone-based fluorescence microscope.

    Science.gov (United States)

    Cho, Soohee; Islas-Robles, Argel; Nicolini, Ariana M; Monks, Terrence J; Yoon, Jeong-Yeol

    2016-12-15

    The use of organ-on-a-chip (OOC) platforms enables improved simulation of the human kidney's response to nephrotoxic drugs. The standard method of analyzing nephrotoxicity from existing OOC has majorly consisted of invasively collecting samples (cells, lysates, media, etc.) from an OOC. Such disruptive analyses potentiate contamination, disrupt the replicated in vivo environment, and require expertize to execute. Moreover, traditional analyses, including immunofluorescence microscopy, immunoblot, and microplate immunoassay are essentially not in situ and require substantial time, resources, and costs. In the present work, the incorporation of fluorescence nanoparticle immunocapture/immunoagglutination assay into an OOC enabled dual-mode monitoring of drug-induced nephrotoxicity in situ. A smartphone-based fluorescence microscope was fabricated as a handheld in situ monitoring device attached to an OOC. Both the presence of γ-glutamyl transpeptidase (GGT) on the apical brush-border membrane of 786-O proximal tubule cells within the OOC surface, and the release of GGT to the outflow of the OOC were evaluated with the fluorescence scatter detection of captured and immunoagglutinated anti-GGT conjugated nanoparticles. This dual-mode assay method provides a novel groundbreaking tool to enable the internal and external in situ monitoring of the OOC, which may be integrated into any existing OOCs to facilitate their subsequent analyses. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Robust sleep quality quantification method for a personal handheld device.

    Science.gov (United States)

    Shin, Hangsik; Choi, Byunghun; Kim, Doyoon; Cho, Jaegeol

    2014-06-01

    The purpose of this study was to develop and validate a novel method for sleep quality quantification using personal handheld devices. The proposed method used 3- or 6-axes signals, including acceleration and angular velocity, obtained from built-in sensors in a smartphone and applied a real-time wavelet denoising technique to minimize the nonstationary noise. Sleep or wake status was decided on each axis, and the totals were finally summed to calculate sleep efficiency (SE), regarded as sleep quality in general. The sleep experiment was carried out for performance evaluation of the proposed method, and 14 subjects participated. An experimental protocol was designed for comparative analysis. The activity during sleep was recorded not only by the proposed method but also by well-known commercial applications simultaneously; moreover, activity was recorded on different mattresses and locations to verify the reliability in practical use. Every calculated SE was compared with the SE of a clinically certified medical device, the Philips (Amsterdam, The Netherlands) Actiwatch. In these experiments, the proposed method proved its reliability in quantifying sleep quality. Compared with the Actiwatch, accuracy and average bias error of SE calculated by the proposed method were 96.50% and -1.91%, respectively. The proposed method was vastly superior to other comparative applications with at least 11.41% in average accuracy and at least 6.10% in average bias; average accuracy and average absolute bias error of comparative applications were 76.33% and 17.52%, respectively.

  8. Thresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.

    Science.gov (United States)

    Pichler, M; Damberger, A; Schwendenwein, I; Gasteiner, J; Drillich, M; Iwersen, M

    2014-03-01

    Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA ≥ 1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood

  9. A novel 1050nm handheld OCT imaging system for pediatric retinoblastoma patients: translation from laboratory bench to clinical study (Conference Presentation)

    Science.gov (United States)

    Nadiarnykh, Oleg; Moll, Annette C.; de Boer, Johannes F.

    2016-03-01

    We demonstrate a novel optical coherence tomography system specifically developed and validated for clinical imaging of retinoblastoma tumors in pediatric patients. The existing treatment options for this malignant tumor of the retina aim at reduction of tumor (re)growth risks, and vision preservation. The choice of optimal treatment strongly depends on skilled and detailed clinical assessment. Currently, the patients at risk are periodically monitored with retinal imaging for possible morphological changes over time, and new tumor seedings, as the existing real-time diagnostic tools are limited. Three-dimensional visualization of tissue layer and microvasculature at improved axial and lateral resolution of interference-based OCT imaging provides sensitivity for detection of vital tumor tissue concurrent with local treatment. Our METC-approved system accommodates for the range of optical parameters of infants' eyes, and uses the 1050nm wavelength to access the deeper choroid layers of retina. The prototype is designed for patients in supine position under general anesthesia, where ergonomic handheld module is connected to fiber-based optical setup via umbilical cord. The system conforms to clinical safety requirements, including fully isolated low-voltage electric circuit. Focusing is performed with a mechanically tunable lens, where resolution is 6 µm axially, and varies with focusing at 10-18µm laterally. We will present optical design, performance limitations, and results of the ongoing clinical study, including the increased OCT diagnostic sensitivity in three dimensions in comparison with the established clinical imaging modalities. We will discuss images of early, active, and treated tumors, as well as follow-up on patients after local and systemic treatments.

  10. Acoustical method of whole-body hydration status monitoring

    Science.gov (United States)

    Sarvazyan, A. P.; Tsyuryupa, S. N.; Calhoun, M.; Utter, A.

    2016-07-01

    An acoustical handheld hydration monitor (HM) for assessing the water balance of the human body was developed. Dehydration is a critical public health problem. Many elderly over age of 65 are particularly vulnerable as are infants and young children. Given that dehydration is both preventable and reversible, the need for an easy-to-perform method for the detection of water imbalance is of the utmost clinical importance. The HM is based on an experimental fact that ultrasound velocity in muscle is a linear function of water content and can be referenced to the hydration status of the body. Studies on the validity of HM for the assessment of whole-body hydration status were conducted in the Appalachian State University, USA, on healthy young adults and on elderly subjects residing at an assisted living facility. The HM was able to track changes in total body water during periods of acute dehydration and rehydration in athletes and day-to-day and diurnal variability of hydration in elderly. Results of human studies indicate that HM has a potential to become an efficient tool for detecting abnormal changes in the body hydration status.

  11. Phone use while driving: results from an observational survey.

    Science.gov (United States)

    Wundersitz, L N

    2014-01-01

    The aim of this study was to quantify the level of handheld phone use when driving in South Australia. The study also sought to investigate any driver, site, and vehicle characteristics associated with handheld phone use to inform countermeasure development and publicity campaigns. An on-road observational survey of handheld phone use was undertaken as part of a larger restraint use survey. The survey was conducted at 61 sites in metropolitan Adelaide and rural regions within South Australia on weekdays and a weekend in 2009. A total of 64 (0.6%) of the 11,524 drivers observed during the survey were using handheld phones. Handheld phone usage rates ranged from 0.8 percent in metropolitan Adelaide to 0.3 percent in the rural region of The Riverland. Of all driver, site, and vehicle characteristics examined, the only statistically significant difference in handheld phone usage was for the number of vehicle occupants. The odds of a driver using a handheld phone while traveling alone was over 4 times higher than for a driver traveling with passengers. The level of handheld phone use among drivers in South Australia appears to be low relative to other jurisdictions. The level of enforcement activity and severity of penalties do not offer a clear explanation for the higher levels of compliance with phone laws. Given the rate of increase in phone technology, it is important to conduct regular roadside surveys of phone use among drivers to monitor trends in usage over time.

  12. SU-F-J-140: Using Handheld Stereo Depth Cameras to Extend Medical Imaging for Radiation Therapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, C; Xing, L; Yu, S [Stanford University, Stanford, CA (United States)

    2016-06-15

    Purpose: A correct body contour is essential for the accuracy of dose calculation in radiation therapy. While modern medical imaging technologies provide highly accurate representations of body contours, there are times when a patient’s anatomy cannot be fully captured or there is a lack of easy access to CT/MRI scanning. Recently, handheld cameras have emerged that are capable of performing three dimensional (3D) scans of patient surface anatomy. By combining 3D camera and medical imaging data, the patient’s surface contour can be fully captured. Methods: A proof-of-concept system matches a patient surface model, created using a handheld stereo depth camera (DC), to the available areas of a body contour segmented from a CT scan. The matched surface contour is then converted to a DICOM structure and added to the CT dataset to provide additional contour information. In order to evaluate the system, a 3D model of a patient was created by segmenting the body contour with a treatment planning system (TPS) and fabricated with a 3D printer. A DC and associated software were used to create a 3D scan of the printed phantom. The surface created by the camera was then registered to a CT model that had been cropped to simulate missing scan data. The aligned surface was then imported into the TPS and compared with the originally segmented contour. Results: The RMS error for the alignment between the camera and cropped CT models was 2.26 mm. Mean distance between the aligned camera surface and ground truth model was −1.23 +/−2.47 mm. Maximum deviations were < 1 cm and occurred in areas of high concavity or where anatomy was close to the couch. Conclusion: The proof-of-concept study shows an accurate, easy and affordable method to extend medical imaging for radiation therapy planning using 3D cameras without additional radiation. Intel provided the camera hardware used in this study.

  13. Handheld skin printer: in situ formation of planar biomaterials and tissues.

    Science.gov (United States)

    Hakimi, Navid; Cheng, Richard; Leng, Lian; Sotoudehfar, Mohammad; Ba, Phoenix Qing; Bakhtyar, Nazihah; Amini-Nik, Saeid; Jeschke, Marc G; Günther, Axel

    2018-05-15

    We present a handheld skin printer that enables the in situ formation of biomaterial and skin tissue sheets of different homogeneous and architected compositions. When manually positioned above a target surface, the compact instrument (weight <0.8 kg) conformally deposits a biomaterial or tissue sheet from a microfluidic cartridge. Consistent sheet formation is achieved by coordinating the flow rates at which bioink and cross-linker solution are delivered, with the speed at which a pair of rollers actively translate the cartridge along the surface. We demonstrate compatibility with dermal and epidermal cells embedded in ionically cross-linkable biomaterials (e.g., alginate), and enzymatically cross-linkable proteins (e.g., fibrin), as well as their mixtures with collagen type I and hyaluronic acid. Upon rapid crosslinking, biomaterial and skin cell-laden sheets of consistent thickness, width and composition were obtained. Sheets deposited onto horizontal, agarose-coated surfaces were used for physical and in vitro characterization. Proof-of-principle demonstrations for the in situ formation of biomaterial sheets in murine and porcine excisional wound models illustrate the capacity of depositing onto inclined and compliant wound surfaces that are subject to respiratory motion. We expect the presented work will enable the in situ delivery of a wide range of different cells, biomaterials, and tissue adhesives, as well as the in situ fabrication of spatially organized biomaterials, tissues, and biohybrid structures.

  14. A Handheld, Free Roaming, Data Display for DIII-D Diagnostic Data

    International Nuclear Information System (INIS)

    Broesch, J.D.; Phillips, J.C.; Petersen, P.I.; Hansink, M.J.

    1999-01-01

    Standard handheld test instruments such as voltmeters and portable oscilloscopes are useful for making basic measurements necessary for the operation and maintenance of large experiments such as the DIII-D magnetic fusion research facility. Some critical diagnostic information, however, is available only on system computers. Often this diagnostic information is located in computer databases and requires synthesis via computational algorithms to be of practical use to the technician. Unfortunately, this means the data is typically only available via computer screens located at fixed locations. One common way to provide mobile information is to have one operator sit at a console and read the data to the mobile technician via radio. This is inefficient in as much as it requires two people. Even more importantly the operator-to-technician voice link introduces significant delays and errors that may hinder response times. To address these concerns of personnel utilization and efficiency, we have developed a remote display based on an rf-data link that can be carried with a technician as he moves about the facility. This display can provide the technician with any information needed from the stationary database. This paper will discuss the overall architecture as well as the individual modules for the mobile data display. Lessons learned, as well as techniques for improving the usefulness of such systems, will be presented

  15. Remote control of safety and technological mining processes in underground coal mines

    Energy Technology Data Exchange (ETDEWEB)

    Marjanovic, D. (Elektronska Industrija RO IRI OOUR Razvoj, Nis (Yugoslavia))

    1989-02-01

    Discusses importance of data relevant to remote monitoring of production and safety at work in underground coal mines. The EI PS 2000 multi-purpose system developed by Elektronska Industrija, Nis, for use with AP-X1 and AP-X2 microcomputers in Serbian mines is described. Component parts include the CUM-8 central unit, the CIP-8 communication interface processor, the SNM-64 disjunction unit, the NM-64 energy supply unit and the CRT alarm monitor. This system is designed to warn of mine fires, methane and coal dust explosions, to help in evacuating mine crews, to control production processes and mine management and other functions. 8 refs

  16. Geocam Space: Enhancing Handheld Digital Camera Imagery from the International Space Station for Research and Applications

    Science.gov (United States)

    Stefanov, William L.; Lee, Yeon Jin; Dille, Michael

    2016-01-01

    Handheld astronaut photography of the Earth has been collected from the International Space Station (ISS) since 2000, making it the most temporally extensive remotely sensed dataset from this unique Low Earth orbital platform. Exclusive use of digital handheld cameras to perform Earth observations from the ISS began in 2004. Nadir viewing imagery is constrained by the inclined equatorial orbit of the ISS to between 51.6 degrees North and South latitude, however numerous oblique images of land surfaces above these latitudes are included in the dataset. While unmodified commercial off-the-shelf digital cameras provide only visible wavelength, three-band spectral information of limited quality current cameras used with long (400+ mm) lenses can obtain high quality spatial information approaching 2 meters/ground pixel resolution. The dataset is freely available online at the Gateway to Astronaut Photography of Earth site (http://eol.jsc.nasa.gov), and now comprises over 2 million images. Despite this extensive image catalog, use of the data for scientific research, disaster response, commercial applications and visualizations is minimal in comparison to other data collected from free-flying satellite platforms such as Landsat, Worldview, etc. This is due primarily to the lack of fully-georeferenced data products - while current digital cameras typically have integrated GPS, this does not function in the Low Earth Orbit environment. The Earth Science and Remote Sensing (ESRS) Unit at NASA Johnson Space Center provides training in Earth Science topics to ISS crews, performs daily operations and Earth observation target delivery to crews through the Crew Earth Observations (CEO) Facility on board ISS, and also catalogs digital handheld imagery acquired from orbit by manually adding descriptive metadata and determining an image geographic centerpoint using visual feature matching with other georeferenced data, e.g. Landsat, Google Earth, etc. The lack of full geolocation

  17. Actor networks in strategic niche management : insights from social network theory

    NARCIS (Netherlands)

    Caniëls, M.C.J.; Romijn, H.A.

    2008-01-01

    This paper contributes to Strategic Niche Management (SNM), an analytical technique designed to facilitate the introduction and diffusion of radically new sustainable technologies through societal experiments. According to SNM, intensive networking among social actors is a crucial process for the

  18. Strategic niche management and sustainable innovation journeys : theory, findings, research agenda, and policy

    NARCIS (Netherlands)

    Schot, J.W.; Geels, F.W.

    2008-01-01

    This article discusses empirical findings and conceptual elaborations of the last 10 years in strategic niche management research (SNM). The SNM approach suggests that sustainable innovation journeys can be facilitated by creating technological niches, i.e. protected spaces that allow the

  19. MATERIAL CONTROL ACCOUNTING INMM

    Energy Technology Data Exchange (ETDEWEB)

    Hasty, T.

    2009-06-14

    Since 1996, the Mining and Chemical Combine (MCC - formerly known as K-26), and the United States Department of Energy (DOE) have been cooperating under the cooperative Nuclear Material Protection, Control and Accounting (MPC&A) Program between the Russian Federation and the U.S. Governments. Since MCC continues to operate a reactor for steam and electricity production for the site and city of Zheleznogorsk which results in production of the weapons grade plutonium, one of the goals of the MPC&A program is to support implementation of an expanded comprehensive nuclear material control and accounting (MC&A) program. To date MCC has completed upgrades identified in the initial gap analysis and documented in the site MC&A Plan and is implementing additional upgrades identified during an update to the gap analysis. The scope of these upgrades includes implementation of MCC organization structure relating to MC&A, establishing material balance area structure for special nuclear materials (SNM) storage and bulk processing areas, and material control functions including SNM portal monitors at target locations. Material accounting function upgrades include enhancements in the conduct of physical inventories, limit of error inventory difference procedure enhancements, implementation of basic computerized accounting system for four SNM storage areas, implementation of measurement equipment for improved accountability reporting, and both new and revised site-level MC&A procedures. This paper will discuss the implementation of MC&A upgrades at MCC based on the requirements established in the comprehensive MC&A plan developed by the Mining and Chemical Combine as part of the MPC&A Program.

  20. Drift from the Use of Hand-Held Knapsack Pesticide Sprayers in Boyacá (Colombian Andes).

    Science.gov (United States)

    García-Santos, Glenda; Feola, Giuseppe; Nuyttens, David; Diaz, Jaime

    2016-05-25

    Offsite pesticide losses in tropical mountainous regions have been little studied. One example is measuring pesticide drift soil deposition, which can support pesticide risk assessment for surface water, soil, bystanders, and off-target plants and fauna. This is considered a serious gap, given the evidence of pesticide-related poisoning in those regions. Empirical data of drift deposition of a pesticide surrogate, Uranine tracer, within one of the highest potato-producing regions in Colombia, characterized by small plots and mountain orography, is presented. High drift values encountered in this study reflect the actual spray conditions using hand-held knapsack sprayers. Comparison between measured and predicted drift values using three existing empirical equations showed important underestimation. However, after their optimization based on measured drift information, the equations showed a strong predictive power for this study area and the study conditions. The most suitable curve to assess mean relative drift was the IMAG calculator after optimization.

  1. 3D Scan of Ornamental Column (huabiao Using Terrestrial LiDAR and Hand-held Imager

    Directory of Open Access Journals (Sweden)

    W. Zhang

    2015-08-01

    Full Text Available In ancient China, Huabiao was a type of ornamental column used to decorate important buildings. We carried out 3D scan of a Huabiao located in Peking University, China. This Huabiao was built no later than 1742. It is carved by white marble, 8 meters in height. Clouds and various postures of dragons are carved on its body. Two instruments were used to acquire the point cloud of this Huabiao, a terrestrial LiDAR (Riegl VZ-1000 and a hand-held imager (Mantis Vision F5. In this paper, the details of the experiment were described, including the differences between these two instruments, such as working principle, spatial resolution, accuracy, instrument dimension and working flow. The point clouds obtained respectively by these two instruments were compared, and the registered point cloud of Huabiao was also presented. These should be of interest and helpful for the research communities of archaeology and heritage.

  2. Electrotactile Feedback for Handheld Devices with Touch Screen and Simulation of Roughness.

    Science.gov (United States)

    Altinsoy, M E; Merchel, S

    2012-01-01

    We present a novel electrotactile display that can be integrated into current handheld devices with touch screens. In this display, tactile information is presented to the fingertip of the user by transmitting small currents through electrodes. Experiments were conducted to investigate the perception of simulated textures using this electrotactile display technique. One fundamental feature of texture, which is the focus of this study, is roughness. The aim of the first experiment was to investigate the relationship between electrotactile stimulation parameters such as current and pulse frequency and the perception of roughness. An increase in the current magnitude resulted in an increase in perceived roughness. The aim of the second experiment was to investigate parameter combinations of electrotactile stimuli can be used to simulate textures. Subjects adjusted the intensity and frequency of the current stimuli until the simulated textures were perceived as being equal to reference textures such as sandpapers of varying grit numbers and grooved woods with varying groove widths. Subjects tended to find an electrotactile stimulus with a high current magnitude and a low pulse frequency more suitable to represent rough surfaces. They tended to find just-perceptible current magnitudes suitable for very smooth surfaces and did not show a preference for any frequency.

  3. Clinical assessment of blood glucose homeostasis in horses: comparison of a continuous glucose monitoring system with a combined intravenous glucose and insulin test protocol.

    Science.gov (United States)

    Johnson, P J; Wiedmeyer, C E; LaCarrubba, A; Messer, N T; Dingfelder, H A; Cogswell, A M; Amorim, J R R; Ganjam, V K

    2011-01-01

    The combined glucose-insulin test (CGIT) is helpful for evaluating insulin sensitivity. A continuous glucose monitoring system (CGMS) reports changes in interstitial glucose concentrations as they occur in the blood. Use of the CGMS minimizes animal contact and may be useful when performing a CGIT. Results obtained using a CGMS are useful for the evaluation of glucose responses during the evaluation of insulin sensitivity in equids. Seven mature, obese ponies. Ponies were equipped with CGMS for determination of interstitial glucose concentrations. Glucose (150 mg/kg, i.v.) and insulin (0.1 U/kg, i.v.) were administered and blood glucose concentrations determined at (minutes after time zero) 1, 5, 15, 25, 35, 45, 60, 75, 90, 105, and 120 with a hand-held glucometer. Blood chemistry results were compared with simultaneously obtained results using CGMS. Concordance coefficients determined for comparison of blood glucose concentrations determined by a hand-held glucometer and those determined by CGMS after the zero time point were 0.623, 0.764, 0.834, 0.854, and 0.818 (for delays of 0, 5, 10, 15, and 20 minutes, respectively). Interstitial glucose concentrations obtained by the CGMS compared favorably to blood glucose concentrations. CGMS may be useful for assessment of glucose dynamics in the CGIT. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  4. Handheld echocardiography versus auscultation for detection of rheumatic heart disease.

    Science.gov (United States)

    Godown, Justin; Lu, Jimmy C; Beaton, Andrea; Sable, Craig; Mirembe, Grace; Sanya, Richard; Aliku, Twalib; Yu, Sunkyung; Lwabi, Peter; Webb, Catherine L; Ensing, Gregory J

    2015-04-01

    Rheumatic heart disease (RHD) remains a major public health concern in developing countries, and routine screening has the potential to improve outcomes. Standard portable echocardiography (STAND) is far more sensitive than auscultation for the detection of RHD but remains cost-prohibitive in resource-limited settings. Handheld echocardiography (HAND) is a lower-cost alternative. The purpose of this study was to assess the incremental value of HAND over auscultation to identify RHD. RHD screening was completed for schoolchildren in Gulu, Uganda, by using STAND performed by experienced echocardiographers. Any child with mitral or aortic regurgitation or stenosis plus a randomly selected group of children with normal STAND findings underwent HAND and auscultation. STAND and HAND studies were interpreted by 6 experienced cardiologists using the 2012 World Heart Federation criteria. Sensitivity and specificity of HAND and auscultation for the detection of RHD and pathologic mitral or aortic regurgitation were calculated by using STAND as the gold standard. Of 4773 children who underwent screening with STAND, a subgroup of 1317 children underwent HAND and auscultation. Auscultation had uniformly poor sensitivity for the detection of RHD or valve disease. Sensitivity was significantly improved by using HAND compared with auscultation for the detection of definite RHD (97.8% vs 22.2%), borderline or definite RHD (78.4% vs 16.4%), and pathologic aortic insufficiency (81.8% vs 13.6%). Auscultation alone is a poor screening test for RHD. HAND significantly improves detection of RHD and may be a cost-effective screening strategy for RHD in resource-limited settings. Copyright © 2015 by the American Academy of Pediatrics.

  5. Design, construction and performance of a portable handheld electrohydrodynamic multi-needle spray gun for biomedical applications.

    Science.gov (United States)

    Sofokleous, Panagiotis; Stride, Eleanor; Bonfield, William; Edirisinghe, Mohan

    2013-01-01

    Electrohydrodynamic (EHD) processing has attracted substantial interest in the technological and pharmaceutical sectors in recent years. Given the complexity of the process, exploring new ideas for EHD electrospraying and electrospinning delivery is a challenge. In this article, the design, construction and testing of a portable handheld EHD multi-needle device are described to produce multifunctional particles and fibers. Solid and encapsulated polymer particles and fibers were generated in order to study the performance of the device. The intrinsic properties of the feed solution/suspension and the processing conditions were adjusted to ensure robustness of the process and give uniform and reproducible products, with diameters ranging from the sub-micrometer scale to a few micrometers. These products have a broad range of applications in many advanced industrial sectors e.g. drug delivery systems, wound dressing patches, low calorie food products and cosmetics. Copyright © 2012 Elsevier B.V. All rights reserved.

  6. Analysis of the role of an interfacility SNM accounting system

    International Nuclear Information System (INIS)

    McDonnel, J.L.; Chilton, P.D.; Kufahl, G.E.; Vergari, A.A.; Dunn, D.R.

    1982-01-01

    Lawrence Livermore National Laboratory (LLNL) undertook the task of analyzing the actual and potential value of an interfacility NRC material accounting system in deterring and detecting both material diversion and facility material accounting data falsification. The most important conclusion is that only relatively minor changes are needed to upgrade the current NRC interfacility reporting system. The emphasis of the task was on evaluating the usefulness of an NRC-monitored material accounting information system in providing protection against accounting fraud at the plant management or corporate level. The Nuclear Materials Management and Safeguards System (NMMSS) and the NRC Safeguards Status Report System (SSRS), the principal constituents of the current interfacility NRC material accounting information system, are described. Their relationship is shown in two information flow diagrams. Deterministic accounting checks and balances are discussed, both for the current NRC interfacility material accounting system and for an upgraded system. Detection mechanisms are described that would use currently available data and that could be exercised by the NRC in its safeguards management role. Additional checks and balances are recommended, with corresponding changes in data reporting requirements, to upgrade NRC interfacility material accounting system

  7. 78 FR 67225 - Amendments to Material Control and Accounting Regulations

    Science.gov (United States)

    2013-11-08

    ... Amendments to Material Control and Accounting Regulations AGENCY: Nuclear Regulatory Commission. ACTION... for material control and accounting (MC&A) of special nuclear material (SNM). The goal of this... for control and accounting of SNM that is held by a licensee. The MC&A regulations ensure that the...

  8. 76 FR 50767 - In the Matter of USEC Inc., American Centrifuge Lead Cascade Facility, and American Centrifuge...

    Science.gov (United States)

    2011-08-16

    ...; License Nos. SNM-7003, SNM-2011] In the Matter of USEC Inc., American Centrifuge Lead Cascade Facility, and American Centrifuge Plant; Order Extending the Date by Which the Direct Transfer of Licenses Is To... American Centrifuge Lead Cascade Facility (Lead Cascade) and American Centrifuge Plant (ACP), respectively...

  9. Handheld mechanical nociceptive threshold testing in dairy cows - intra-individual variation, inter-observer agreement and variation over time.

    Science.gov (United States)

    Raundal, Peter M; Andersen, Pia H; Toft, Nils; Forkman, Björn; Munksgaard, Lene; Herskin, Mette S

    2014-11-01

    To examine the use of handheld methodology to assess mechanical nociceptive threshold (MNT) on cows kept loose-housed. Prospective randomized partial cross-over experimental study. A one-factor (test day) design was used to evaluate MNT over time. One hundred and fifteen healthy, loose-housed Danish Holstein cattle. We evaluated intra-individual variation, inter-observer agreement and variation over time of MNT using two handheld devices and two stimulation sites. Mechanical, ramped stimulations were performed with an algometer (6.5 mm diameter steel probe, 0-10.0 kgf) or an electronic von Frey device (plastic tip with diameter 0.8 mm, 0-1000 gf). Each cow received 5-6 consecutive stimulations within a 2 × 5 cm skin area on the dorsal or lateral aspect of the left third metatarsus until an avoidance reaction occurred. We investigated the difference in precision [expressed as coefficient of variation (CV)] between the combinations of devices and stimulation sites. The inter-observer agreement and the difference in MNT between test day 1, 3, 7, 10 and 24 were investigated for selected combinations. Data were analysed in mixed models and Bland-Altman as relevant. The CVs did not differ [range 0.34-0.52 (p = 0.1)]. Difference between observers (95% limits) was 0.2 kgf (2.8) and 4 gf (369) for the algometer and von Frey device, respectively. Mechanical nociceptive threshold increased from 361 on test day one to 495 gf on test day 24 (p < 0.01). All methods showed a high degree of intra-individual variation, and no combination of device and stimulation site showed superior precision. Mean difference between observers was low, and MNT was not consistent over time. Further development of the methods is required before they can be used in research to investigate possible relations between claw lesions and hyperalgesia. © 2014 The Authors Veterinary Anaesthesia and Analgesia published by John Wiley & Sons Ltd on behalf of Association of Veterinary Anaesthetists and the

  10. An Empirical Study Of User Acceptance Of Online Social Networks Marketing

    Directory of Open Access Journals (Sweden)

    Olumayowa Mulero

    2013-07-01

    Full Text Available The explosion of Internet usage has drawn the attention of researchers towards online Social Networks Marketing (SNM. Research has shown that a number of the Internet users are distrustful and indecisive, when it comes to the use of social networks marketing system. Therefore, there is a need for researchers to identify some of the factors that determine users’ acceptance of social networks marketing using Technology Acceptance Model (TAM. This study extended the Technology Acceptance Model theoretical framework to predict consumer acceptance of social networks marketing within Western Cape Province of South Africa. The research model was tested using data collected from 470 questionnaires and analysed using linear regression. The results showed that user intentions to use SNM are strongly and positively correlated with user acceptance of using SNM systems. Empirical results confirmed that perceived credibility and perceived usefulness are the strongest determinant in predicting user intentions to use SNM system.

  11. Extra-oral dental radiography for disaster victims using a flat panel X-ray detector and a hand-held X-ray generator.

    Science.gov (United States)

    Ohtani, M; Oshima, T; Mimasaka, S

    2017-12-01

    Forensic odontologists commonly incise the skin for post-mortem dental examinations when it is difficult to open the victim's mouth. However, it is prohibited by law to incise dead bodies without permission in Japan. Therefore, we attempted using extra-oral dental radiography, using a digital X-ray equipment with rechargeable batteries, to overcome this restriction. A phantom was placed in the prone position on a table, and three plain dental radiographs were used per case: "lateral oblique radiographs" for left and right posterior teeth and a "contact radiograph" for anterior teeth were taken using a flat panel X-ray detector and a hand-held X-ray generator. The resolving power of the images was measured by a resolution test chart, and the scattered X-ray dose was measured using an ionization chamber-type survey meter. The resolving power of the flat panel X-ray detector was 3.0 lp/mm, which was less than that of intra-oral dental methods, but the three extra-oral plain dental radiographs provided the overall dental information from outside of the mouth, and this approach was less time-consuming. In addition, the higher dose of scattered X-rays was laterally distributed, but the dose per case was much less than that of intra-oral dental radiographs. Extra-oral plain dental radiography can be used for disaster victim identification by dental methods even when it is difficult to open the mouth. Portable and rechargeable devices, such as a flat panel X-ray detector and a hand-held X-ray generator, are convenient to bring and use anywhere, even at a disaster scene lacking electricity and water.

  12. Hip strength assessment using handheld dynamometry is subject to intertester bias when testers are of different sex and strength

    DEFF Research Database (Denmark)

    Thorborg, K; Bandholm, T; Schick, M

    2013-01-01

    Handheld dynamometry (HHD) is a promising tool for obtaining reliable hip strength measurements in the clinical setting, but intertester reliability has been questioned, especially in situations where testers exhibit differences in upper-extremity muscle strength (male vs female). The purpose...... of this study was to examine the intertester reliability concerning strength assessments of hip abduction, adduction, external and internal rotation, flexion and extension using HHD, and to test whether systematic differences in test values exist between testers of different upper-extremity strength. Fifty...... healthy individuals (29 women), aged 25 ± 5 years were included. Two physiotherapist students (one female, one male) of different upper-extremity strength performed the measurements. The tester order and strength test order were randomized. Intraclass correlation coefficients were used to quantify...

  13. Development of a Handheld Line Information Reader and Generator for Efficient Management of Optical Communication Lines.

    Science.gov (United States)

    Lee, Jaeyul; Kwon, Hyungwoo; Song, Jaewon; Jeon, Mansik; Kim, Jeehyun

    2017-08-24

    A handheld line information reader and a line information generator were developed for the efficient management of optical communication lines. The line information reader consists of a photo diode, trans-impedance amplifier, voltage amplifier, microcontroller unit, display panel, and communication modules. The line information generator consists of a laser diode, laser driving circuits, microcontroller unit, and communication modules. The line information reader can detect the optical radiation field of the test line by bending the optical fiber. To enhance the sensitivity of the line information reader, an additional lens was used with a focal length of 4.51 mm. Moreover, the simulation results obtained through BeamPROP ® software from Synopsys, Inc. demonstrated a stronger optical radiation field of the fiber due to a longer transmission wavelength and larger bending angle of the fiber. Therefore, the developed devices can be considered as useful tools for the efficient management of optical communication lines.

  14. Utility of hand-held echocardiography in outpatient pediatric cardiology management.

    Science.gov (United States)

    Riley, Alan; Sable, Craig; Prasad, Aparna; Spurney, Christopher; Harahsheh, Ashraf; Clauss, Sarah; Colyer, Jessica; Gierdalski, Marcin; Johnson, Ashley; Pearson, Gail D; Rosenthal, Joanna

    2014-12-01

    Adult patient series have shown hand-held echocardiography (echo) units (HHE) to be accurate for rapid diagnosis and triage. This is the first study to evaluate the ability of HHE to inform decision making in outpatient pediatric cardiology. New pediatric cardiology patients in outpatient clinics staffed by six pediatric cardiologists (experience 1-17 years) were prospectively enrolled if an echocardiogram (echo) was ordered during their initial visit. After history and physical examination and before a standard echo, the cardiologists performed a bedside HHE examination (GE Vscan 1.7-3.8 MHz), documented findings, and made a clinical decision. Diagnoses and decisions based on HHE were compared with final management after the standard echo. The study enrolled 101 subjects (ages 9 days to 19 years). The cardiologists considered HHE imaging adequate for decision making for 80 of the 101 subjects. For 77 of the 80 subjects with acceptable HHE imaging (68/68 normal and 9/12 abnormal standard echoes), the HHE-based primary diagnoses and decisions agreed with the final management. The sensitivity of HHE was 75 % (95 % confidence interval [CI] 43-94 %) and the positive predictive value 100 % (95 % CI 66-100 %) for pediatric heart disease. The agreement between standard echocardiography and HHE imaging was substantial (κ = 0.82). Excluding one of the least experienced cardiologists, HHE provided the basis for correct cardiac diagnoses and management for all the subjects with acceptable HHE imaging (58/58 normal and 9/9 abnormal echoes). In outpatient pediatric cardiology, HHE has potential as a tool to complement physical examination. Further investigation is needed to evaluate how value improves with clinical experience.

  15. Flexible CMOS low-noise amplifiers for beyond-3G wireless hand-held devices

    Science.gov (United States)

    Becerra-Alvarez, Edwin C.; Sandoval-Ibarra, Federico; de la Rosa, José M.

    2009-05-01

    This paper explores the use of reconfigurable Low-Noise Amplifiers (LNAs) for the implementation of CMOS Radio Frequency (RF) front-ends in the next generation of multi-standard wireless transceivers. Main circuit strategies reported so far for multi-standard LNAs are reviewed and a novel flexible LNA intended for Beyond-3G RF hand-held terminals is presented. The proposed LNA circuit consists of a two-stage topology that combines inductive-source degeneration with PMOS-varactor based tuning network and a programmable load to adapt its performance to different standard specifications without penalizing the circuit noise and with a reduced number of inductors as compared to previous reported reconfigurable LNAs. The circuit has been designed in a 90-nm CMOS technology to cope with the requirements of the GSM, WCDMA, Bluetooth and WLAN (IEEE 802.11b-g) standards. Simulation results, including technology and packaging parasitics, demonstrate correct operation of the circuit for all the standards under study, featuring NF13.3dB and IIP3>10.9dBm, over a 1.85GHz-2.4GHz band, with an adaptive power consumption between 17mW and 22mW from a 1-V supply voltage. Preliminary experimental measurements are included, showing a correct reconfiguration operation within the operation band.

  16. The Takei Handheld Dynamometer: An Effective Clinical Outcome Measure Tool for Hand and Wrist Function in Boxing.

    Science.gov (United States)

    Gatt, Ian; Smith-Moore, Sophie; Steggles, Charlie; Loosemore, Mike

    2018-05-01

    The aim of this article was to explore retrospectively the Takei dynamometer as a valid and reliable outcome measure tool for hand and wrist pathology in the Great Britain amateur boxing squad between 2010 and 2014. Longitudinal retrospective injury surveillance of the Great Britain boxing squad was performed from 2010 to 2014. The location, region affected, description, and duration of each injury were recorded by the team doctor and team physiotherapists. For each significant injury, we recorded hand grip scores using the Takei handheld dynamometer and compared the scores with baseline measures. At the hand, fractures and dislocations were highly detected with an average difference of 40.2% ( P 20% should be highly considered for significant pathology. The Takei dynamometer is a valid and reliable outcome measure tool for hand and wrist pathologies in boxing. Our study highlights the importance of appropriate clinical tools to guide injury management in this sport.

  17. Handheld Raman Spectroscopy for the Distinction of Essential Oils Used in the Cosmetics Industry

    Directory of Open Access Journals (Sweden)

    Paul Vargas Jentzsch

    2015-05-01

    Full Text Available Essential oils are highly appreciated by the cosmetics industry because they have antimicrobial and antioxidant properties, among others. Since essential oils are natural products, their inclusion in cosmetic formulations is a common practice. Currently, low-quality and/or adulterated essential oils can be found on the market; therefore, analytical methods for control are required. Raman spectroscopy is a versatile technique that can be used for quality control tasks; the portability of modern devices expand the analytical possibilities also to in situ measurements. Fifteen essential oils of interest for the cosmetics industry were measured using a handheld Raman spectrometer, and the assignment of the main bands observed in their average spectra was proposed. In most cases, it is possible to distinguish the essential oils by a simple visual inspection of their characteristic Raman bands. However, for essential oils extracted from closely-related vegetable species and containing the same main component in a very high proportion, the visual inspection of the spectra may be not enough, and the application of chemometric methods is suggested. Characteristic Raman bands for each essential oil can be used to both identify the essential oils and detect adulterations.

  18. Investigations of active interrogation techniques to detect special nuclear material in maritime environments: Standoff interrogation of small- and medium-sized cargo ships

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Thomas M., E-mail: millertm@ornl.gov; Patton, Bruce W.; Grogan, Brandon R.; Henkel, James J.; Murphy, Brian D.; Johnson, Jeffrey O.; Mihalczo, John T.

    2013-12-01

    In this work, several active interrogation (AI) sources are evaluated to determine their usefulness in detecting the presence of special nuclear material (SNM) in fishing trawlers, small cargo transport ships, and luxury yachts at large standoff distances from the AI source and detector. This evaluation is performed via computational analysis applying Monte Carlo methods with advanced variance reduction techniques. The goal is to determine the AI source strength required to detect the presence of SNM. The general conclusion of this study is that AI is not reliable when SNM is heavily shielded and not tightly coupled geometrically with the source and detector, to the point that AI should not be considered a via interrogation option in these scenarios. More specifically, when SNM is shielded by hydrogenous material large AI source strengths are required if detection is based on neutrons, which is not surprising. However, if the SNM is shielded by high-Z material the required AI source strengths are not significantly different if detection is based on neutrons or photons, which is somewhat surprising. Furthermore, some of the required AI source strengths that were calculated are very large. These results coupled with the realities of two ships moving independently at sea and other assumptions made during this analysis make the use of standoff AI in the maritime environment impractical.

  19. Investigations of active interrogation techniques to detect special nuclear material in maritime environments: Standoff interrogation of small- and medium-sized cargo ships

    International Nuclear Information System (INIS)

    Miller, Thomas M.; Patton, Bruce W.; Grogan, Brandon R.; Henkel, James J.; Murphy, Brian D.; Johnson, Jeffrey O.; Mihalczo, John T.

    2013-01-01

    In this work, several active interrogation (AI) sources are evaluated to determine their usefulness in detecting the presence of special nuclear material (SNM) in fishing trawlers, small cargo transport ships, and luxury yachts at large standoff distances from the AI source and detector. This evaluation is performed via computational analysis applying Monte Carlo methods with advanced variance reduction techniques. The goal is to determine the AI source strength required to detect the presence of SNM. The general conclusion of this study is that AI is not reliable when SNM is heavily shielded and not tightly coupled geometrically with the source and detector, to the point that AI should not be considered a via interrogation option in these scenarios. More specifically, when SNM is shielded by hydrogenous material large AI source strengths are required if detection is based on neutrons, which is not surprising. However, if the SNM is shielded by high-Z material the required AI source strengths are not significantly different if detection is based on neutrons or photons, which is somewhat surprising. Furthermore, some of the required AI source strengths that were calculated are very large. These results coupled with the realities of two ships moving independently at sea and other assumptions made during this analysis make the use of standoff AI in the maritime environment impractical

  20. Signal estimation and change detection in tank data for nuclear safeguards

    International Nuclear Information System (INIS)

    Burr, Tom; Suzuki, Mitsutoshi; Howell, John; Longo, Claire E.; Hamada, Michael S.

    2011-01-01

    Process monitoring (PM) is increasingly important in nuclear safeguards as a complement to mass-balance based nuclear materials accounting (NMA). Typically, PM involves more frequent but lower quality measurements than NMA. While NMA estimates special nuclear material (SNM) mass balances and uncertainties, PM often tracks SNM attributes qualitatively or in the case of solution monitoring (SM) tracks bulk mass and volume. Automatic event marking is used in several nuclear safeguards PM systems. The aims are to locate the start and stop times and signal changes associated with key events. This paper describes results using both real and simulated SM data to quantify the errors associated with imperfect marking of start and stop times of tank events such as receipts and shipments. In the context of safeguards, one can look both forward and backward in modest time intervals to recognize events. Event marking methods evaluated include differencing, multi-scale principal component analysis using wavelets, and piecewise linear regression (PLR). All methods are evaluated on both raw and smoothed data, and several smoothing options are compared, including standard filters, hybrid filters, and local kernel smoothing. The main finding for real and simulated examples considered is that a two-step strategy is most effective. First, any reasonably effective initial smoother is used to provide a good initial guess at change point locations. Second, PLR is applied, looking for one change point at a time. In contrast, PLR that allows for multiple change points simultaneously has worse performance.

  1. Assessment of Lower Limb Muscle Strength and Power Using Hand-Held and Fixed Dynamometry: A Reliability and Validity Study

    Science.gov (United States)

    Perraton, Luke G.; Bower, Kelly J.; Adair, Brooke; Pua, Yong-Hao; Williams, Gavin P.; McGaw, Rebekah

    2015-01-01

    Introduction Hand-held dynamometry (HHD) has never previously been used to examine isometric muscle power. Rate of force development (RFD) is often used for muscle power assessment, however no consensus currently exists on the most appropriate method of calculation. The aim of this study was to examine the reliability of different algorithms for RFD calculation and to examine the intra-rater, inter-rater, and inter-device reliability of HHD as well as the concurrent validity of HHD for the assessment of isometric lower limb muscle strength and power. Methods 30 healthy young adults (age: 23±5yrs, male: 15) were assessed on two sessions. Isometric muscle strength and power were measured using peak force and RFD respectively using two HHDs (Lafayette Model-01165 and Hoggan microFET2) and a criterion-reference KinCom dynamometer. Statistical analysis of reliability and validity comprised intraclass correlation coefficients (ICC), Pearson correlations, concordance correlations, standard error of measurement, and minimal detectable change. Results Comparison of RFD methods revealed that a peak 200ms moving window algorithm provided optimal reliability results. Intra-rater, inter-rater, and inter-device reliability analysis of peak force and RFD revealed mostly good to excellent reliability (coefficients ≥ 0.70) for all muscle groups. Concurrent validity analysis showed moderate to excellent relationships between HHD and fixed dynamometry for the hip and knee (ICCs ≥ 0.70) for both peak force and RFD, with mostly poor to good results shown for the ankle muscles (ICCs = 0.31–0.79). Conclusions Hand-held dynamometry has good to excellent reliability and validity for most measures of isometric lower limb strength and power in a healthy population, particularly for proximal muscle groups. To aid implementation we have created freely available software to extract these variables from data stored on the Lafayette device. Future research should examine the reliability

  2. Handheld mechanical nociceptive threshold testing in dairy cows – intra-individual variation, inter-observer agreement and variation over time

    Science.gov (United States)

    Raundal, Peter M; Andersen, Pia H; Toft, Nils; Forkman, Björn; Munksgaard, Lene; Herskin, Mette S

    2014-01-01

    Objective To examine the use of handheld methodology to assess mechanical nociceptive threshold (MNT) on cows kept loose-housed. Study design Prospective randomized partial cross-over experimental study. A one-factor (test day) design was used to evaluate MNT over time. Animals One hundred and fifteen healthy, loose-housed Danish Holstein cattle. Methods We evaluated intra-individual variation, inter-observer agreement and variation over time of MNT using two handheld devices and two stimulation sites. Mechanical, ramped stimulations were performed with an algometer (6.5 mm diameter steel probe, 0–10.0 kgf) or an electronic von Frey device (plastic tip with diameter 0.8 mm, 0–1000 gf). Each cow received 5–6 consecutive stimulations within a 2 × 5 cm skin area on the dorsal or lateral aspect of the left third metatarsus until an avoidance reaction occurred. We investigated the difference in precision [expressed as coefficient of variation (CV)] between the combinations of devices and stimulation sites. The inter-observer agreement and the difference in MNT between test day 1, 3, 7, 10 and 24 were investigated for selected combinations. Data were analysed in mixed models and Bland-Altman as relevant. Results The CVs did not differ [range 0.34–0.52 (p = 0.1)]. Difference between observers (95% limits) was 0.2 kgf (2.8) and 4 gf (369) for the algometer and von Frey device, respectively. Mechanical nociceptive threshold increased from 361 on test day one to 495 gf on test day 24 (p < 0.01). Conclusion and clinical relevance All methods showed a high degree of intra-individual variation, and no combination of device and stimulation site showed superior precision. Mean difference between observers was low, and MNT was not consistent over time. Further development of the methods is required before they can be used in research to investigate possible relations between claw lesions and hyperalgesia. PMID:24734991

  3. Westinghouse Hanford Company FY 1995 Materials Management Plan (MMP)

    International Nuclear Information System (INIS)

    Higginson, M.C.

    1994-10-01

    The safe and sound operation of facilities and storage of nuclear material are top priorities within Hanford's environmental management, site restoration mission. The projected materials estimates, based on the Materials Management Plan (MMP) assumptions outlined below, were prepared for Department of Energy (DOE) use in long-range planning. The Hanford MMP covers the period FY 1995 through FY 2005, as directed by DOE. All DOE Richland Operations (RL) Office facilities are essentially funded by the Office of Transition and Facilities Management, Environmental Restoration and Waste Management (EM). These facilities include PUREX, the UO 3 plant, N-Reactor, T-Plant, K-Basins, FFTF, PFP and the 300 Area Fuel Fabrication facilities. Currently DP provides partial funding for the latter two facilities. Beginning in FY 1996 (in accordance with DOE-HQ MMP assumptions), EM will fund expenses related to the storage, monitoring, and safeguarding of all Special Nuclear Material (SNM) in the PFP. Ownership and costs related to movement and/or stabilization of that material will belong to EM programs (excluding NE material). It is also assumed that IAEA will take over inventory validation and surveillance of EM owned SNM at this time (FY 1996)

  4. Use of a Digital Camera to Monitor the Growth and Nitrogen Status of Cotton

    Directory of Open Access Journals (Sweden)

    Biao Jia

    2014-01-01

    Full Text Available The main objective of this study was to develop a nondestructive method for monitoring cotton growth and N status using a digital camera. Digital images were taken of the cotton canopies between emergence and full bloom. The green and red values were extracted from the digital images and then used to calculate canopy cover. The values of canopy cover were closely correlated with the normalized difference vegetation index and the ratio vegetation index and were measured using a GreenSeeker handheld sensor. Models were calibrated to describe the relationship between canopy cover and three growth properties of the cotton crop (i.e., aboveground total N content, LAI, and aboveground biomass. There were close, exponential relationships between canopy cover and three growth properties. And the relationships for estimating cotton aboveground total N content were most precise, the coefficients of determination (R2 value was 0.978, and the root mean square error (RMSE value was 1.479 g m−2. Moreover, the models were validated in three fields of high-yield cotton. The result indicated that the best relationship between canopy cover and aboveground total N content had an R2 value of 0.926 and an RMSE value of 1.631 g m−2. In conclusion, as a near-ground remote assessment tool, digital cameras have good potential for monitoring cotton growth and N status.

  5. Ground and river water quality monitoring using a smartphone-based pH sensor

    Directory of Open Access Journals (Sweden)

    Sibasish Dutta

    2015-05-01

    Full Text Available We report here the working of a compact and handheld smartphone-based pH sensor for monitoring of ground and river water quality. Using simple laboratory optical components and the camera of the smartphone, we develop a compact spectrophotometer which is operational in the wavelength range of 400-700 nm and having spectral resolution of 0.305 nm/pixel for our equipment. The sensor measures variations in optical absorption band of pH sensitive dye sample in different pH solutions. The transmission image spectra through a transmission grating gets captured by the smartphone, and subsequently converted into intensity vs. wavelengths. Using the designed sensor, we measure water quality of ground water and river water from different locations in Assam and the results are found to be reliable when compared with the standard spectrophotometer tool. The overall cost involved for development of the sensor is relatively low. We envision that the designed sensing technique could emerge as an inexpensive, compact and portable pH sensor that would be useful for in-field applications.

  6. Seeding Social Norms about Energy Conservation among Girl Scouts

    Science.gov (United States)

    Bernstein, Debra; Puttick, Gillian

    2014-01-01

    Three studies examined whether a social norm message (SNM) to Girl Scouts who had completed an energy conservation program would impact behavior and attitudes. Studies 1 and 2 were conducted with girls recently completing the program, study 3 was conducted with girls completing the program one year earlier. Results suggest that the SNM may impact…

  7. Using exotic atoms to keep borders safe

    International Nuclear Information System (INIS)

    Stocki, T J; Olsthoorn, J; Jason, A; Miyadera, H; Esch, E-I; Hoteling, N J; Heffner, R H; Green, A; Adelmann, A

    2011-01-01

    Muons, created by a particle accelerator, can be used to scan cargo for special nuclear materials (SNM). These muons have a sufficiently long lifetime and are penetrating enough that they can be used to actively scan cargo to ensure the non-proliferation of SNM. A set of 'proof-of-concept' experiments have been performed to show that active muon analysis can be used. Experiments were performed at high intensity, medium energy particle accelerators (TRIUMF and PSI). Negative muons form exotic atoms with one electron replaced by the muon. Since the muon is captured in an excited state, it will give off x-rays which can be detected by high purity germanium detectors. The characteristic x-ray spectrum can be potentially used to identify nuclides. The muonic x-rays corresponding to the SNM of interest have been measured, even with the use of various shielding configurations composed of lead, iron, polyethylene, or fibreglass. These preliminary results show that muon scanning systems can be successfully used to find shielded SNM, helping to ensure the safety of all citizens.

  8. Using exotic atoms to keep borders safe

    International Nuclear Information System (INIS)

    Jason, A.; Miyadera, H.; Esch, E.I.; Hoteling, N.J.; Adelmann, A.; Heffner, R.H.; Green, A.; Olsthoorn, J.; Stocki, T.J.

    2010-01-01

    Muons, created by a particle accelerator, can be used to scan cargo for special nuclear materials (SNM). These muons exist long enough and are penetrating enough that they can be used to actively scan cargo to ensure the non-proliferation of SNM. A set of 'proof-of-concept' experiments have been performed to show that active muon analysis can be used. Experiments were performed at high intensity, medium energy particle accelerators (TRIUMF and PSI). Negative muons form exotic atoms with one electron replaced by the muon. Since the muon is captured in an excited state, it will give off x-rays which can be detected by high purity germanium detectors. These characteristic x-rays can be used to identify the nuclide. The muonic x-rays corresponding to the SNM of interest have been measured, even with the use of various shielding configurations composed of lead, iron, polyethylene, or fiberglass. These preliminary results show that muons can be successfully used to find shielded SNM. The safety of North Americans can be protected by the use of this technology.

  9. Sexual response in patients treated with sacral neuromodulation for lower urinary tract symptoms or fecal incontinence.

    Science.gov (United States)

    van Voskuilen, A C; Oerlemans, D J; Gielen, N; Lansen-Koch, S M P; Weil, E H J; van Lankveld, J J D M; van den Hombergh, U; Baeten, C G M I; van Kerrenbroeck, P E V

    2012-01-01

    To determine whether sacral neuromodulation (SNM) for urinary symptoms or fecal incontinence gives improvement of female sexual function and whether improvement is due to physiological or psychological factors. Between 2002 and 2008, 8 patients had an array of questionnaires before and after SNM implantation. The questionnaires were: the Questionnaire for Screening for Sexual Dysfunctions, the Golombok Rust Inventory of Sexual Satisfaction, the Symptom Checklist-90, the Maudsley Marital Questionnaire and the McGill-Mah Orgasm Questionnaire. Three of these 8 patients underwent vaginal plethysmography before and after implantation. No statistically significant changes were found, although there seems to be a trend toward improvement in orgasm scores. In plethysmography all 3 patients showed increased vaginal pulse amplitude with the stimulator turned on with both erotic and non-erotic stimuli. This study does not show a clear effect of SNM on sexual function, although there seems to be an improvement in orgasm scores. The lack of response on psychological questionnaires and the increase in vaginal pulse amplitude after SNM implantation indicate that there might be a physiological response. Copyright © 2012 S. Karger AG, Basel.

  10. Nuclear materials inventory plan

    International Nuclear Information System (INIS)

    Doerr, R.W.; Nichols, D.H.

    1982-03-01

    In any processing, manufacturing, or active storage facility it is impractical to assume that any physical security system can prevent the diversion of Special Nuclear Material (SNM). It is, therefore, the responsibility of any DOE Contractor, Licensee, or other holder of SNM to provide assurance that loss or diversion of a significant quantity of SNM is detectable. This ability to detect must be accomplishable within a reasonable time interval and can be accomplished only by taking physical inventories. The information gained and decisions resulting from these inventories can be no better than the SNM accounting system and the quality of measurements performed for each receipt, removal and inventory. Inventories interrupt processing or production operations, increase personnel exposures, and can add significantly to the cost of any operation. Therefore, realistic goals for the inventory must be defined and the relationship of the inherent parameters used in its validation be determined. Purpose of this document is to provide a statement of goals and a plan of action to achieve them

  11. Locating sensors for detecting source-to-target patterns of special nuclear material smuggling: a spatial information theoretic approach.

    Science.gov (United States)

    Przybyla, Jay; Taylor, Jeffrey; Zhou, Xuesong

    2010-01-01

    In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM) smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.

  12. OR14-V-Uncertainty-PD2La Uncertainty Quantification for Nuclear Safeguards and Nondestructive Assay Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Nicholson, Andrew D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Croft, Stephen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McElroy, Robert Dennis [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-08-01

    The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically provide error bars and also partition total uncertainty into “random” and “systematic” components so that, for example, an error bar can be developed for the total mass estimate in multiple items. Uncertainty Quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed and achievable using modern statistical methods.

  13. Special Nuclear Material Gamma-Ray Signatures for Reachback Analysts

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, Steven Charles [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-29

    These are slides on special nuclear material gamma-ray signatures for reachback analysts for an LSS Spectroscopy course. The closing thoughts for this presentation are the following: SNM materials have definite spectral signatures that should be readily recognizable to analysts in both bare and shielded configurations. One can estimate burnup of plutonium using certain pairs of peaks that are a few keV apart. In most cases, one cannot reliably estimate uranium enrichment in an analogous way to the estimation of plutonium burnup. The origin of the most intense peaks from some SNM items may be indirect and from ‘associated nuclides.' Indirect SNM signatures sometimes have commonalities with the natural gamma-ray background.

  14. Project plan remove special nuclear material from PFP project plutonium finishing plant; TOPICAL

    International Nuclear Information System (INIS)

    BARTLETT, W.D.

    1999-01-01

    This plan presents the overall objectives, description, justification and planning for the Plutonium Finishing Plant (PFP) Remove Special Nuclear Material (SNM) Materials. The intent of this plan is to describe how this project will be managed and integrated with other facility stabilization and deactivation activities. This plan supplements the overall integrated plan presented in the Plutonium Finishing Plant Integrated Project Management Plan (IPMP), HNF-3617,Rev. 0. This project plan is the top-level definitive project management document for PFP Remove SNM Materials project. It specifies the technical, schedule, requirements and the cost baselines to manage the execution of the Remove SNM Materials project. Any deviations to the document must be authorized through the appropriate change control process

  15. Project plan remove special nuclear material from PFP project plutonium finishing plant

    International Nuclear Information System (INIS)

    BARTLETT, W.D.

    1999-01-01

    This plan presents the overall objectives, description, justification and planning for the Plutonium Finishing Plant (PFP) Remove Special Nuclear Material (SNM) Materials. The intent of this plan is to describe how this project will be managed and integrated with other facility stabilization and deactivation activities. This plan supplements the overall integrated plan presented in the Plutonium Finishing Plant Integrated Project Management Plan (IPMP), HNF-3617, Rev. 0. This project plan is the top-level definitive project management document for PFP Remove SNM Materials project. It specifies the technical, schedule, requirements and the cost baselines to manage the execution of the Remove SNM Materials project. Any deviations to the document must be authorized through the appropriate change control process

  16. Locating Sensors for Detecting Source-to-Target Patterns of Special Nuclear Material Smuggling: A Spatial Information Theoretic Approach

    Directory of Open Access Journals (Sweden)

    Xuesong Zhou

    2010-08-01

    Full Text Available In this paper, a spatial information-theoretic model is proposed to locate sensors for detecting source-to-target patterns of special nuclear material (SNM smuggling. In order to ship the nuclear materials from a source location with SNM production to a target city, the smugglers must employ global and domestic logistics systems. This paper focuses on locating a limited set of fixed and mobile radiation sensors in a transportation network, with the intent to maximize the expected information gain and minimize the estimation error for the subsequent nuclear material detection stage. A Kalman filtering-based framework is adapted to assist the decision-maker in quantifying the network-wide information gain and SNM flow estimation accuracy.

  17. A self-sustainable winery, an advanced passive building and remote monitoring of environments in wineries

    Directory of Open Access Journals (Sweden)

    Roger Boulton

    2017-08-01

    Full Text Available The self-sustainable winery was conceived in 2006 and the intention was to create a building and its related utility systems that would operate independently from the energy and water grids and to eliminate hydrocarbon fuels from its operation, capture and sequester the carbon dioxide from its fermentations and create a zero carbon footprint facility. The winery was the highest scoring LEED building at any university when it was completed and the first LEED Platinum Winery in the USA. The adjacent Jess Jackson sustainable winery building is a highly passive research and utility space that will house the advanced energy and water systems that make this off-grid performance possible. Together these buildings will operate every daily in energy and water positive modes and at capacities, which exceed the demands even during the harvest season. The data system incorporated into these buildings for one hundred and fifty research fermentors, fourteen teaching fermentors will also monitor all energy, water and building activities in a secure, cloud-based software system that supports both web and handheld access, with the potential for bidirectional date and control functions. This data network has been extended to include real time monitoring of temperature, humidity, carbon dioxide and volatile organic compounds in five production areas within two commercial winery sites and two creamery facilities, located more than 100 km from Davis. This now provides an example of a distributed dynamic network for the monitoring of the built environment in remote commercial food and wine facilities.

  18. Design of a Handheld Pseudo Random Coded UWB Radar for Human Sensing

    Directory of Open Access Journals (Sweden)

    Xia Zheng-huan

    2015-10-01

    Full Text Available This paper presents the design of a handheld pseudo random coded Ultra-WideBand (UWB radar for human sensing. The main tasks of the radar are to track the moving human object and extract the human respiratory frequency. In order to achieve perfect penetrability and good range resolution, m sequence with a carrier of 800 MHz is chosen as the transmitting signal. The modulated m-sequence can be generated directly by the high-speed DAC and FPGA to reduce the size of the radar system, and the mean power of the transmitting signal is 5 dBm. The receiver has two receiving channels based on hybrid sampling, the first receiving channel is to sample the reference signal and the second receiving channel is to obtain the radar echo. The real-time pulse compression is computed in parallel with a group of on-chip DSP48E slices in FPGA to improve the scanning rate of the radar system. Additionally, the algorithms of moving target tracking and life detection are implemented using Intel’s micro-processor, and the detection results are sent to the micro displayer fixed on the helmet. The experimental results show that the moving target located at less than 16 m far away from the wall can be tracked, and the respiratory frequency of the static human at less than 14 m far away from the wall can be extracted.

  19. Handheld Diagnostic Device Delivers Quick Medical Readings

    Science.gov (United States)

    2014-01-01

    To monitor astronauts' health remotely, Glenn Research Center awarded SBIR funding to Cambridge, Massachusetts-based DNA Medical Institute, which developed a device capable of analyzing blood cell counts and a variety of medical biomarkers. The technology will prove especially useful in rural areas without easy access to labs.

  20. Can handheld micropower impulse radar technology be used to detect pneumothorax? Initial experience in a European trauma centre.

    Science.gov (United States)

    Albers, C E; Haefeli, P C; Zimmermann, H; de Moya, M; Exadaktylos, A K

    2013-05-01

    Pneumothoraces are a common injury pattern in emergency medicine. Rapid and safe identification can reduce morbidity and mortality. A new handheld, battery powered device, the Pneumoscan (CE 561036, PneumoSonics Inc., Cleveland, OH, USA), using micropower impulse radar (MIR) technology, has recently been introduced in Europe for the rapid and reliable detection of PTX. However, this technology has not yet been tested in trauma patients. This is the first quality control evaluation to report on emergency room performance of a new device used in the trauma setting. This study was performed at a Level I trauma centre in Switzerland. All patients with thoracic trauma and undergoing chest X-ray and CT-scan were eligible for the study. Readings were performed before the chest X-ray and CT scan. The patients had eight lung fields tested (four on each side). All readings with the Pneumoscan were performed by two junior residents in our department who had previously received an instructional tutorial of 15min. The qualitative MIR results were blinded, and stored on the device. We then compared the results of the MIR to those of the clinical examination, chest X-ray and CT-scan. 50 patients were included, with a mean age of 46 (SD 17) years. Seven patients presented with PTX diagnosed by CT; six of these were detected by Pneumoscan, leading to an overall sensitivity of 85.7 (95% confidence interval 42.1-99.6)%. Only two of seven PTX were found during clinical examination and on chest X-ray (sensitivity 28.6 (95% CI 3.7-71.0)%). Of the remaining 43 of 50 patients without PTX, one false-positive PTX was found by the Pneumoscan, resulting in a specificity of 97.7 (95% CI 87.7-99.9)%. The Pneumoscan is an easy to use handheld technology with reliable results. In this series, the sensitivity to detect a PTX by the Pneumoscan was higher than by clinical examination and chest X-ray. Further studies with higher case numbers and a prospective study design are needed to confirm our