WorldWideScience

Sample records for ground grid systems

  1. Active ground system for mean voltage grids; Sistema de aterramento ativo para redes de media tensao

    Energy Technology Data Exchange (ETDEWEB)

    Filgueira, Francisco Pazos [Iberdrola, Bilbao (Spain); Amezua, Aitor; Gutierrez, Itziar [Oldar Electronica, Bilbao (Spain); Garcia, Juanmari [Ingeteam T and D, Bizkaia (SPAIN); Valverde, Victor [EHU/UPV, Bizkaia (Spain)

    2010-06-15

    The system described in this paper is based on multifrequency, which combines a new device of power electronic with a control and protection system. The technology facilitates the operation and maintenance of the distribution grid, overcoming some limitations of the traditional systems, and becomes possible improvements in the service quality and continuity of supply (author)

  2. Model grid and infiltration values for the transient ground-water flow model, Death Valley regional ground-water flow system, Nevada and California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This digital data set defines the model grid and infiltration values simulated in the transient ground-water flow model of the Death Valley regional ground-water...

  3. Model grid and infiltration values for the transient ground-water flow model, Death Valley regional ground-water flow system, Nevada and California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This digital data set defines the model grid and infiltration values simulated in the transient ground-water flow model of the Death Valley regional ground-water...

  4. A New Method of Grounding Grid Design

    Directory of Open Access Journals (Sweden)

    Feng Zhen-Bao

    2016-01-01

    Full Text Available In order to equalize the electric potential distribution of the grounding grid surface, and improve the safety level of the grounding grid, method for optimal arrangement of conducts in the grounding grid is proposed in this paper. The calculation results about maximum touch voltages and mesh potentials show that the method can reduce touch voltage and equilibrium surface potential. It is shown that the design of the grounding grid is related to not only the soil environment, but also the rectangular shape. Comparing with other methods, the method proposed in the paper can reduce maximum touch voltage about 12%. This method also can be applied in a uniform and non-uniform soil, rectangular and square grounding grids. The optimize effect meets the related standards of the power industry.

  5. Instant 960 Grid System

    CERN Document Server

    Tres, Diego

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. Instant 960 Grid System uses step-by-step instructions, covering the basic understanding needed to create a quick, high quality responsive website prototype using the 960 Grid System.The book is intended for beginner web developers and information architects looking to create a quick responsive website prototype. Basic knowledge of web development and a little understanding of grids is encouraged.

  6. Achievement of the best design for unequally spaced grounding grids

    Directory of Open Access Journals (Sweden)

    El-Sayed M. El-Refaie

    2015-03-01

    Also, unequal spacing can reduce the cost of the grids and enhance the level of safety for people and equipments. In this paper two different approaches were used to determine the best possible configuration of grounding grid. These approaches based on sequential multiplicative and sequential power techniques.

  7. 3G POWER GRID SYSTEM

    OpenAIRE

    Saiyad Tausif Ali *; Gaurav Pawar; Pragati Rathi; Mandar Pathak

    2016-01-01

    3G Power grid system is dual side stream of electricity and automated construct information and distributed advanced energy delivery network. In this 3G Power grid system avoided the thermal and hydro sources of energy. By using the solar power and wind power energy will generate electricity according with the condition of nature. 3G Power grid system provides the facility of generating as well as marketing of electricity not only for the producers but also for consumers. By using megabytes o...

  8. "Grid" versus "Ground": Optimized Design of Low-Distortion Projections Using Existing Projection Types Rigorously Georeferenced to the National Spatial Reference System

    Science.gov (United States)

    Dennis, M. L.; Armstrong, M. L.

    2016-12-01

    With the adoption of a new geometric datum in 2022, NOAA's National Geodetic Survey (NGS) will update the State Plane Coordinate System (SPCS). This update may consist simply of offsetting northings and/or eastings of existing SPCS projection zones. However, there is significant interest among NGS customers for another type of projected coordinate system: Low-Distortion Projections (LDPs). Although LDPs are presently not endorsed or supported by NGS, an assessment of LDP feasibility and performance is warranted within the context of updating the National Spatial Reference System (NSRS). LDPs are conformal map projections that minimize linear distortion at the topographic surface, manifested as a difference in distance between a pair of projected "grid" coordinates and the true horizontal "ground" distance. For SPCS, the differences can exceed a few hundred parts per million (ppm), and it can be problematic for engineering and surveying applications. Although such distortion cannot be eliminated, an LDP design method is presented that yields optimal results even for large areas of variable elevation. This approach can provide much lower distortion than the traditional method of scaling SPCS to ground, often called "modified" SPCS (MSPCS). MSPCS was included in training provided by NGS beginning in the 1960s, but it does not optimally minimize linear distortion. LDP systems have been adopted throughout the United States. One such system is the Oregon Coordinate Reference System (OCRS). Figure 1 compares distortion of an MSPCS for Bend, Oregon, to the OCRS zone for that area, where the green shading indicates distortion within ±20 ppm (2 cm/km or 0.1 ft/mile). The difference in performance is striking, even though both use the same projection type. Because LDPs cover larger areas, one can be used for many projects, whereas in most cases one MSPCS (and sometimes more) must be defined for every project. Importantly, the presented method for designing LDPs is based on

  9. Smart Grid Communications System Blueprint

    Science.gov (United States)

    Clark, Adrian; Pavlovski, Chris

    2010-10-01

    Telecommunications operators are well versed in deploying 2G and 3G wireless networks. These networks presently support the mobile business user and/or retail consumer wishing to place conventional voice calls and data connections. The electrical power industry has recently commenced transformation of its distribution networks by deploying smart monitoring and control devices throughout their networks. This evolution of the network into a `smart grid' has also motivated the need to deploy wireless technologies that bridge the communication gap between the smart devices and information technology systems. The requirements of these networks differ from traditional wireless networks that communications operators have deployed, which have thus far forced energy companies to consider deploying their own wireless networks. We present our experience in deploying wireless networks to support the smart grid and highlight the key properties of these networks. These characteristics include application awareness, support for large numbers of simultaneous cell connections, high service coverage and prioritized routing of data. We also outline our target blueprint architecture that may be useful to the industry in building wireless and fixed networks to support the smart grid. By observing our experiences, telecommunications operators and equipment manufacturers will be able to augment their current networks and products in a way that accommodates the needs of the emerging industry of smart grids and intelligent electrical networks.

  10. Joint Grid System Used in Embedding Technique

    Institute of Scientific and Technical Information of China (English)

    李孝伟; 范绪箕

    2003-01-01

    The joint grid system, which consists of the developed collar grid, the virtual grid and other grids, wasused in the embedding technique to solve the problem of finding interpolating cells of the internal and externalboundary points near the joint regions. With different boundary plane generated along different fixed surface, thecollar grid obtained using hyperbolic partial equations can ensure to generate high-quality grids and to provide realinterpolating cells for the boundary points in the blanking regions. The virtual grid was used to convert solid wallboundary conditions into an interface condition, however, no fluid flow computations were conducted within thevirtual grid. The computational result of body-strake-wing shows that the current developed embedding techniquewith joint grid system can effectively treat the geometry and can more accurately predict the flow over complexcon-figuration with intersecting surfaces.

  11. Usability Issues of Grid System Software

    Institute of Scientific and Technical Information of China (English)

    Zhi-Wei Xu; Hao-Jie Zhou; Guo-Jie Li

    2006-01-01

    This paper addresses the problem why grid technology has not spread as fast as the Web technology of the 1990's. In the past 10 years, considerable efforts have been put into grid computing. Much progress has been made and more importantly, fundamental challenges and essential issues of this field are emerging. This paper focuses on the area of grid system software research, and argues that usability of grid system software must be enhanced. It identifies four usability issues, drawing from international grid research experiences. It also presents advances by the Vega Grid team in addressing these challenges.

  12. PQ Control Based Grid Connected DG Systems

    Directory of Open Access Journals (Sweden)

    P Siva Srinivas1 ,

    2015-10-01

    Full Text Available Distributed generation (DG generally refer to small scale electric power generators produce electricity that is bound to an electric distribution system. Distributed generation systems such as photovoltaic (PV or wind energy systems are parts of the future smart grids. By applying intelligent techniques these future grids change as smarter grids. During the past few years electrical energy consumption to the investment is increased when compared to cost on transmission and distribution resulting in compromised reliability and high energy costs. So there is need to change from conventional grid to smart grid. Micro grids consist of small power sources called distributed generation system. Many distributed generation systems such as photovoltaic systems are grid interfaced through power electronic voltage source inverters. In this paper a boost inverter technique is explained and distributed generation sources such as PV and fuel cell are connected in series with the help of PQ controller technique the above system is evaluated.

  13. A grid job monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Dumitrescu, Catalin; /Fermilab; Nowack, Andreas; /Aachen, Tech. Hochsch.; Padhi, Sanjay; /UC, San Diego; Sarkar, Subir; /INFN, Pisa /Pisa, Scuola Normale Superiore

    2010-01-01

    This paper presents a web-based Job Monitoring framework for individual Grid sites that allows users to follow in detail their jobs in quasi-real time. The framework consists of several independent components: (a) a set of sensors that run on the site CE and worker nodes and update a database, (b) a simple yet extensible web services framework and (c) an Ajax powered web interface having a look-and-feel and control similar to a desktop application. The monitoring framework supports LSF, Condor and PBS-like batch systems. This is one of the first monitoring systems where an X.509 authenticated web interface can be seamlessly accessed by both end-users and site administrators. While a site administrator has access to all the possible information, a user can only view the jobs for the Virtual Organizations (VO) he/she is a part of. The monitoring framework design supports several possible deployment scenarios. For a site running a supported batch system, the system may be deployed as a whole, or existing site sensors can be adapted and reused with the web services components. A site may even prefer to build the web server independently and choose to use only the Ajax powered web interface. Finally, the system is being used to monitor a glideinWMS instance. This broadens the scope significantly, allowing it to monitor jobs over multiple sites.

  14. Ground Enterprise Management System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Emergent Space Technologies Inc. proposes to develop the Ground Enterprise Management System (GEMS) for spacecraft ground systems. GEMS will provide situational...

  15. Smart grids concept in electrical distribution system

    Directory of Open Access Journals (Sweden)

    Popović Željko N.

    2012-01-01

    Full Text Available This paper defines key business processes in electrical distribution systems and key elements and priority components that should be (redefined in these processes in order to enable the goals of smart grids concept to be fulfilled in the cost effective way. Activities undertaken in the Power Distribution Company of “Elektrovojvodina” (Serbia, which provide the basis for fulfilling the Smart Grids goals and thus enable full implementation of smart grids concept are presented in details.

  16. Kite Generator System: Grid Integration and Validation

    OpenAIRE

    Ahmed, Mariam; Hably, Ahmad; Bacha, Seddik; Ovalle, Andres

    2014-01-01

    International audience; In this paper, the problem of grid integration of a kite generator system (KGS), is handled. The mechanical power generated by the kite's traction is translated into an electrical one via a permanent magnet synchronous machine. This power is then injected in the grid or used to supply an isolated load after passing a power electronics interface. Control schemes have been developed for grid connected or stand-alone operation and tested on a hardware-in-the-loop simulator.

  17. Production grid systems and their programming

    CERN Document Server

    Kacsuk, P; Stefan, P

    2004-01-01

    Summary form only given. There are a large variety of grid test-beds that can be used for experimental purposes by a small community. However, the number of production grid systems that can be used as a service for a large community is very limited. The current tutorial provides introduction to three of these very few production grid systems. They represent different models and policies of using grid resources and hence understanding and comparing them is an extremely useful exercise to everyone interested in grid technology. The Hungarian ClusterGrid infrastructure connects clusters during the nights and weekends. These clusters are used during the day for educational purposes at the Hungarian universities and polytechnics. Therefore, a unique feature of this grid is the switching mechanism by which the day time and night time working modes are loaded to the computers. In order to manage the system as a production, one, the system is homogeneous, all the machines should install the same grid software package...

  18. Radix Representation of Triangular Discrete Grid System

    Science.gov (United States)

    Ben, J.; Li, Y. L.; Wang, R.

    2016-11-01

    Discrete Global Grid Systems (DGGSs) are spatial references that use a hierarchical tessellation of cells to partition and address the entire globe. It provides an organizational structure that permits fast integration between multiple sources of large and variable geospatial data. Although many endeavors have been done to describe certain discrete grid systems, there still lack of a uniform mathematical framework for them. This paper simplifies the planar class I aperture 4 triangular discrete grid system into a hierarchical lattice model which is proved to be a radix system in the complex number plane. Mathematical properties of the radix system reveal the discrete grid system is equivalent to the set of complex numbers with special form. The conclusion provides a potential way to build a uniform mathematical framework of DGGS and can be used to design efficient encoding and spatial operation scheme for DGGS.

  19. Grid-Tied Photovoltaic Power System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2011-01-01

    A grid-tied photovoltaic (PV) power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. Operating costs of a PV power system are low compared to conventional power technologies. This method can displace the highest-cost electricity during times of peak demand in most climatic regions, and thus reduce grid loading. Net metering is often used, in which independent power producers such as PV power systems are connected to the utility grid via the customers main service panels and meters. When the PV power system is generating more power than required at that location, the excess power is provided to the utility grid. The customer pays the net of the power purchased when the on-site power demand is greater than the onsite power production, and the excess power is returned to the utility grid. Power generated by the PV system reduces utility demand, and the surplus power aids the community. Modern PV panels are readily available, reliable, efficient, and economical, with a life expectancy of at least 25 years. Modern electronics have been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy equal to the modern PV panels. The grid-tied PV power system was successfully designed and developed, and this served to validate the basic principles developed, and the theoretical work that was performed. Grid-tied PV power systems are reliable, maintenance- free, long-life power systems, and are of significant value to NASA and the community. Of particular value are the analytical tools and capabilities that have been successfully developed. Performance predictions can be made confidently for grid-tied PV systems of various scales. The work was done under the NASA Hybrid Power Management (HPM

  20. An Improved Algorithm of Grounding Grids Corrosion Diagnosis Based on Total Least Square Method

    Institute of Scientific and Technical Information of China (English)

    ZHANG Ying-jiao; NIU Tao; WANG Sen

    2011-01-01

    A new model considering corrosion property for grounding grids diagnosis is proposed, which provides reference solutions of ambiguous branches. The constraint total least square method based on singular value decomposition is adopted to improve the effectiveness of grounding grids' diagnosis algorithm. The improvement can weaken the influence of the model's error, which results from the differences between design paper and actual grid. Its influence on touch and step voltages caused by the interior resistance of conductors is taken into account. Simulation results show the validity of this approach.

  1. Grid Voltage Synchronization for Distributed Generation Systems under Grid Fault Conditions

    DEFF Research Database (Denmark)

    Luna, Alvaro; Rocabert, J.; Candela, I.

    2015-01-01

    The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and PV systems, are becoming very demanding. The Transmission System Operators (TSOs) are especially concerned about the Low Voltage Ride Through requirements. Solutions based on the installat......The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and PV systems, are becoming very demanding. The Transmission System Operators (TSOs) are especially concerned about the Low Voltage Ride Through requirements. Solutions based...

  2. Representation of Performance Data in Grid Systems

    Institute of Scientific and Technical Information of China (English)

    时培植; 李三立

    2004-01-01

    The increasingly frequent exchange of performance data in grid systems across heterogeneous platforms requires a uniform "representation" of various types of performance data.This paper reviews the current related research,considers the defect of existing methods,and proposes a new portable description method: grid performance data description (GPDD) using an extensible markup language (XML)-based grid performance data representation language (XGPDRL).GPDD describes the abstract structure,which has excellent extensibility (all types of performance data can be described in one format),efficiency,and flexibility.XGPDRL defines the grammar of the GPDD performance data representation,and is both extensible and portable.For benchmarking purposes,performance data can be collected during runtime,represented in XGPDRL,and analyzed visually using a browser across heterogeneous platforms.GPDD and XGPDRL can conveniently ensure data comprehension across various platforms,and are very suitable for grid performance data representation.

  3. Synchronization in single-phase grid-connected photovoltaic systems under grid faults

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2012-01-01

    The highly increasing penetration of single-phase photovoltaic (PV) systems pushes the grid requirements related to the integration of PV power systems to be updated. These upcoming regulations are expected to direct the grid-connected renewable generators to support the grid operation...... and stability both under grid faulty conditions and under normal operations. Grid synchronization techniques play an important role in the control of single-phase systems in order to fulfill these demands. Thus, it is necessary to evaluate the behaviors of grid synchronization methods in single phase systems...... under grid faults. The focus of this paper is put on the benchmarking of synchronization techniques, mainly about phase locked loop (PLL) based methods, in single-phase PV power systems operating under grid faults. Some faulty mode cases are studied at the end of this paper in order to compare...

  4. FDTD Analysis of the Current Distribution within the Grounding System for a Wind Turbine Generation Tower Struck by Lightning

    Science.gov (United States)

    Nagao, Mitsuhiro; Nagaoka, Naoto; Baba, Yoshihiro; Ametani, Akihiro

    Transient current distribution within the grounding system for a wind-turbine-generation tower of height 61m struck by lightning has been calculated using the finite-difference time-domain (FDTD) method. The grounding grid for the lightning-struck tower considered in this paper is connected electrically via an insulated wire to one neighboring-tower grounding grid located 50m away from it. High-frequency components of a lightning current tend to flow in ground through the grounding grid of the lightning-struck tower, and they become larger with increasing the ground conductivity. Relatively-lower-frequency components of the lightning current flow in ground through each of the two grounding grids roughly in inverse proportion to the grounding resistance of each grid. For example, when two identical grounding grids for the lightning-struck tower and the neighboring tower are buried in the same ground, about 50% of the lightning current flows in the grounding grid for the neighboring tower via the insulated wire connecting these two grounding grids. When the grounding resistance of the neighboring tower is about 1/4 of that for the lightning-struck tower, about 4/5 of the lightning current flows in the neighboring-tower grounding grid. This agrees well with the trend shown by Nagaoka et al. from their measurement in the grounding system for an actual wind-turbine-generation tower struck by natural lightning.

  5. Grid infrastructures for developing mammography CAD systems.

    Science.gov (United States)

    Ramos-Pollan, Raul; Franco, Jose M; Sevilla, Jorge; Guevara-Lopez, Miguel A; de Posada, Naimy Gonzalez; Loureiro, Joanna; Ramos, Isabel

    2010-01-01

    This paper presents a set of technologies developed to exploit Grid infrastructures for breast cancer CAD, that include (1) federated repositories of mammography images and clinical data over Grid storage, (2) a workstation for mammography image analysis and diagnosis and (3) a framework for data analysis and training machine learning classifiers over Grid computing power specially tuned for medical image based data. An experimental mammography digital repository of approximately 300 mammograms from the MIAS database was created and classifiers were built achieving a 0.85 average area under the ROC curve in a dataset of 100 selected mammograms with representative pathological lesions and normal cases. Similar results were achieved with classifiers built for the UCI Breast Cancer Wisconsin dataset (699 features vectors). Now these technologies are being validated in a real medical environment at the Faculty of Medicine in Porto University after a process of integrating the tools within the clinicians workflows and IT systems.

  6. Solar energy grid integration systems "SEGIS"

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2007-10-01

    The inevitable transformation of the electrical grid to a more distributed generation configuration requires solar system capabilities well beyond simple net-metered, grid-connected approaches. Time-of-use and peak-demand rate structures will require more sophisticated systems designs that integrate energy management and/or energy storage into the system architecture. Controlling power flow into and from the utility grid will be required to ensure grid reliability and power quality. Alternative protection strategies will also be required to accommodate large numbers of distributed energy sources. This document provides an overview of the R&D needs and describes some pathways to promising solutions. The solutions will, in many cases, require R&D of new components, innovative inverter/controllers, energy management systems, innovative energy storage and a suite of advanced control algorithms, technical methodologies, protocols and the associated communications. It is expected that these solutions will help to push the “advanced integrated system” and “smart grid” evolutionary processes forward in a faster but focused manner.

  7. 5th Annual Earth System Grid Federation

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Dean N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-04-01

    The purpose of the Fifth Annual Earth System Grid Federation (ESGF) Face-to-Face (F2F) Conference was to present the most recent information on the state of ESGF’s software stack and to identify and address the data needs and gaps for the climate and weather communities that ESGF supports.

  8. Methods for Procuring Power System Flexibility, Greening the Grid

    Energy Technology Data Exchange (ETDEWEB)

    Katz, Jessica; Cochran, Jaquelin; Miller, Mackay

    2015-05-01

    Greening the Grid provides technical assistance to energy system planners, regulators, and grid operators to overcome challenges associated with integrating variable renewable energy into the grid. This document, part of a Greening the Grid toolkit, introduces administrative and incentive-based mechanisms for procuring a cost-effective mix of flexibility sources.

  9. Power system SCADA and smart grids

    CERN Document Server

    Thomas, Mini S

    2015-01-01

    Power System SCADA and Smart Grids brings together in one concise volume the fundamentals and possible application functions of power system supervisory control and data acquisition (SCADA). The text begins by providing an overview of SCADA systems, evolution, and use in power systems and the data acquisition process. It then describes the components of SCADA systems, from the legacy remote terminal units (RTUs) to the latest intelligent electronic devices (IEDs), data concentrators, and master stations, as well as:Examines the building and practical implementation of different SCADA systemsOf

  10. Ground Control System Description Document

    Energy Technology Data Exchange (ETDEWEB)

    Eric Loros

    2001-07-31

    The Ground Control System contributes to the safe construction and operation of the subsurface facility, including accesses and waste emplacement drifts, by maintaining the configuration and stability of the openings during construction, development, emplacement, and caretaker modes for the duration of preclosure repository life. The Ground Control System consists of ground support structures installed within the subsurface excavated openings, any reinforcement made to the rock surrounding the opening, and inverts if designed as an integral part of the system. The Ground Control System maintains stability for the range of geologic conditions expected at the repository and for all expected loading conditions, including in situ rock, construction, operation, thermal, and seismic loads. The system maintains the size and geometry of operating envelopes for all openings, including alcoves, accesses, and emplacement drifts. The system provides for the installation and operation of sensors and equipment for any required inspection and monitoring. In addition, the Ground Control System provides protection against rockfall for all subsurface personnel, equipment, and the engineered barrier system, including the waste package during the preclosure period. The Ground Control System uses materials that are sufficiently maintainable and that retain the necessary engineering properties for the anticipated conditions of the preclosure service life. These materials are also compatible with postclosure waste isolation performance requirements of the repository. The Ground Control System interfaces with the Subsurface Facility System for operating envelopes, drift orientation, and excavated opening dimensions, Emplacement Drift System for material compatibility, Monitored Geologic Repository Operations Monitoring and Control System for ground control instrument readings, Waste Emplacement/Retrieval System to support waste emplacement operations, and the Subsurface Excavation System

  11. Power systems signal processing for smart grids

    CERN Document Server

    Ribeiro, Paulo Fernando; Ribeiro, Paulo Márcio; Cerqueira, Augusto Santiago

    2013-01-01

    With special relation to smart grids, this book provides clear and comprehensive explanation of how Digital Signal Processing (DSP) and Computational Intelligence (CI) techniques can be applied to solve problems in the power system. Its unique coverage bridges the gap between DSP, electrical power and energy engineering systems, showing many different techniques applied to typical and expected system conditions with practical power system examples. Surveying all recent advances on DSP for power systems, this book enables engineers and researchers to understand the current state of the art a

  12. Electricity distribution management Smart Grid system model

    Directory of Open Access Journals (Sweden)

    Wiesław Nowak

    2012-06-01

    Full Text Available This paper presents issues concerning the implementation of Smart Grid solutions in a real distribution network. The main components possible to quick implementation were presented. Realization of these ideas should bring tangible benefi ts to both customers and distribution system operators. Moreover the paper shows selected research results which examine proposed solutions in area of improving supply reliability and reducing energy losses in analysed network.

  13. Electricity distribution management Smart Grid system model

    OpenAIRE

    Wiesław Nowak; Wojciech Bąchorek; Szczepan Moskwa; Rafał Tarko; Waldemar Szpyra; Mariusz Benesz; Andrzej Makuch; Jarosław Łabno; Paweł Mazur

    2012-01-01

    This paper presents issues concerning the implementation of Smart Grid solutions in a real distribution network. The main components possible to quick implementation were presented. Realization of these ideas should bring tangible benefi ts to both customers and distribution system operators. Moreover the paper shows selected research results which examine proposed solutions in area of improving supply reliability and reducing energy losses in analysed network.

  14. 2016 Earth System Grid Federation Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Dean N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-05-10

    The Earth System Grid Federation (ESGF) experienced a major setback in June 2015, when it experienced a security incident that brought all systems to a halt for more than half a year. However, federation developers and management committee members turned the incident into an opportunity to dramatically upgrade the system security and functionality and to develop planning and policy documents to guide ESGF evolution and success. Moreover, despite the incident, ESGF developer working teams continue to make strong and significant progress on various enhancement projects that will help ensure ESGF can meet the needs of the climate community in the coming years.

  15. Ground Enterprise Management System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Spacecraft ground systems are on the cusp of achieving "plug-and-play" capability, i.e., they are approaching the state in which the various components can be...

  16. A Grid Architecture for Manufacturing Database System

    Directory of Open Access Journals (Sweden)

    Laurentiu CIOVICĂ

    2011-06-01

    Full Text Available Before the Enterprise Resource Planning concepts business functions within enterprises were supported by small and isolated applications, most of them developed internally. Yet today ERP platforms are not by themselves the answer to all organizations needs especially in times of differentiated and diversified demands among end customers. ERP platforms were integrated with specialized systems for the management of clients, Customer Relationship Management and vendors, Supplier Relationship Management. They were integrated with Manufacturing Execution Systems for better planning and control of production lines. In order to offer real time, efficient answers to the management level, ERP systems were integrated with Business Intelligence systems. This paper analyses the advantages of grid computing at this level of integration, communication and interoperability between complex specialized informatics systems with a focus on the system architecture and data base systems.

  17. Benchmarking of grid fault modes in single-phase grid-connected photovoltaic systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2012-01-01

    Pushed by the booming installations of single-phase photovoltaic (PV) systems, the grid demands regarding the integration of PV systems are expected to be modified. Hence, the future PV systems should become more active with functionalities of low voltage ride-through (LVRT) and the grid support...... phase systems under grid faults. The intent of this paper is to present a benchmarking of grid fault modes that might come in future single-phase PV systems. In order to map future challenges, the relevant detection and control strategies are discussed. Some faulty modes are studied experimentally...... and provided at the end of this paper. It is concluded that there are extensive control possibilities in single-phase PV systems under grid faults. The Second Order General Integral based PLL technique might be the most promising candidate for future single-phase PV systems because of its fast adaptive...

  18. Benchmarking of Grid Fault Modes in Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede; Zou, Zhixiang

    2013-01-01

    Pushed by the booming installations of singlephase photovoltaic (PV) systems, the grid demands regarding the integration of PV systems are expected to be modified. Hence, the future PV systems should become more active with functionalities of Low Voltage Ride-Through (LVRT) and grid support...... phase systems under grid faults. The intent of this paper is to present a benchmarking of grid fault modes that might come in future single-phase PV systems. In order to map future challenges, the relevant synchronization and control strategies are discussed. Some faulty modes are studied experimentally...... and provided at the end of this paper. It is concluded that there are extensive control possibilities in single-phase PV systems under grid faults. The Second Order General Integral based PLL technique might be the most promising candidate for future single-phase PV systems because of its fast adaptive...

  19. Analysis of the influences of grid-connected PV power system on distribution grids

    Directory of Open Access Journals (Sweden)

    Dumitru Popandron

    2013-12-01

    Full Text Available This paper presents the analysis of producing an electric power of 2.8 MW using a solar photovoltaic plant. The PV will be grid connected to the distribution network. The study is focused on the influences of connecting to the grid of a photovoltaic system, using modern software for analysis, modeling and simulation in power systems.

  20. Danish experiments with a grid system tested in the North Sea shrimp fishery

    DEFF Research Database (Denmark)

    Madsen, Niels; Hansen, K.E.

    2001-01-01

    Grids have been proven successful worldwide as bycatch reducers in shrimp fisheries but have never been tested in the North Sea shrimp fishery. The objectives of this experiment were to develop and test a flexible grid system for the Danish Fladen Ground shrimp (Pandalus borealis) fishery, which...... and during sea trials. Two experiments were conducted with a commercial trawler at the Fladen Ground. A standard shrimp codend was compared to a codend with the grid system simultaneously in a twin trawl rig. There was a relatively large and significant reduction in the grid codend of cod (Gadus morhua......), haddock (Melanogrammus aeglefinus). whiting (Merlangius merlangus), saithe (Pollachius virens), Norway pout (Trisopterus esmarki). Norway lobster, herring (Clupea harengus) and witch (Glyptocephalus cynoglossus) but no significant difference in weight of shrimp and monkfish (Lophius piscatorius...

  1. An Evaluation of Information Consistency in Grid Information Systems

    CERN Document Server

    Field, Laurence

    2016-01-01

    A Grid information system resolves queries that may need to consider all information sources (Grid services), which are widely distributed geographically, in order to enable efficient Grid functions that may utilise multiple cooperating services. Fundamentally this can be achieved by either moving the query to the data (query shipping) or moving the data to the query (data shipping). Existing Grid information system implementations have adopted one of the two approaches. This paper explores the two approaches in further detail by evaluating them to the best possible extent with respect to Grid information system benchmarking metrics. A Grid information system that follows the data shipping approach based on the replication of information that aims to improve the currency for highly-mutable information is presented. An implementation of this, based on an Enterprise Messaging System, is evaluated using the benchmarking method and the consequence of the results for the design of Grid information systems is discu...

  2. GEMS: A Fault Tolerant Grid Job Management System

    OpenAIRE

    Tadepalli, Sriram Satish

    2003-01-01

    The Grid environments are inherently unstable. Resources join and leave the environment without any prior notification. Application fault detection, checkpointing and restart is of foremost importance in the Grid environments. The need for fault tolerance is especially acute for large parallel applications since the failure rate grows with the number of processors and the duration of the computation. A Grid job management system hides the heterogeneity of the Grid and the complexity of the ...

  3. Unmanned Ground Systems Roadmap

    Science.gov (United States)

    2011-07-01

    Squad Mission Support System SOC .............................. Special Operations Command SOFC ............................ Solid Oxide Fuel Cell ...technologies may be used to match a given Use Profile: Table 5. Power Use Profiles Energy Storage Energy Harvesting Fuel Cells Engines Lead Acid...significant amount of research and development in both Government and Industry have been devoted to the areas of energy storage, fuel cells , and small

  4. Grid Converters for Photovoltaic and Wind Power Systems

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Liserre, Marco; Rodriguez, Pedro

    power, operation within a wide range of voltage and frequency, voltage ride-through capability, reactive current injection during faults, grid services support. This book explains the topologies, modulation and control of grid converters for both photovoltaic and wind power applications. In addition...... to power electronics, this book focuses on the specific applications in photovoltaic wind power systems where grid condition is an essential factor. With a review of the most recent grid requirements for photovoltaic and wind power systems, the book discusses these other relevant issues: Modern grid...... inverter topologies for photovoltaic and wind turbines Islanding detection methods for photovoltaic systems Synchronization techniques based on second order generalized integrators (SOGI) Advanced synchronization techniques with robust operation under grid unbalance condition grid filter design and active...

  5. Intrusion Detection System Inside Grid Computing Environment (IDS-IGCE

    Directory of Open Access Journals (Sweden)

    Basappa B. Kodada

    2012-01-01

    Full Text Available Grid Computing is a kind of important information technology which enables resource sharing globally to solve the large scale problem. It is based on networks and able to enable large scale aggregation and sharing of computational, data, sensors and other resources across institutional boundaries. Integrated Globus Tool Kit with Web services is to present OGSA (Open Grid Services Architecture as the standardservice grid architecture. In OGSA, everything is abstracted as a service, including computers, applications, data as well as instruments. The services and resources in Grid are heterogeneous and dynamic, and they also belong to different domains. Grid Services are still new to business system & asmore systems are being attached to it, any threat to it could bring collapse and huge harm. May be intruder come with a new form of attack. Grid Computing is a Global Infrastructure on the internet has led to asecurity attacks on the Computing Infrastructure. The wide varieties of IDS (Intrusion Detection System are available which are designed to handle the specific types of attacks. The technique of [27] will protect future attacks in Service Grid Computing Environment at the Grid Infrastructure but there is no technique can protect these types of attacks inside the grid at the node level. So this paper proposes the Architecture of IDS-IGCE (Intrusion Detection System – Inside Grid Computing Environment which can provide the protection against the complete threats inside the Grid Environment.

  6. 46 CFR 120.376 - Grounded distribution systems (Neutral grounded).

    Science.gov (United States)

    2010-10-01

    ... ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 120.376 Grounded distribution systems... distribution system having a neutral bus or conductor must have the neutral grounded. (c) The neutral or each... generator is connected to the bus, except the neutral of an emergency power generation system must...

  7. Optimum Design Of On Grid Pv System Using Tracking System

    Directory of Open Access Journals (Sweden)

    Saeed Mansour

    2015-05-01

    Full Text Available Abstract The fossil fuel is a main issue in the world due to the increase of fossil fuel cost and the depletion of the fossil fuel with continuous increasing demand on electricity. With continuous decrease of PV panels cost it is interesting to consider generation of electricity from PV system. To provide electric energy to a load in a remote area where electric grid utility is not available or connection with grid utility is available there are two approaches of photovoltaic system PV without tracking system Fixed System and PV with tracking systems. The result shows that the energy production by using PV with tracking system generates more energy in comparison with fixed panels system. However the cost per produced KWH is less in case of using fixed panels. This is the backbone in choice between two approaches of photovoltaic system. In this work a system design and cost analysis for two approaches of photovoltaic system are considered.

  8. A Grid Voltage Measurement Method for Wind Power Systems during Grid Fault Conditions

    Directory of Open Access Journals (Sweden)

    Cheol-Hee Yoo

    2014-11-01

    Full Text Available Grid codes in many countries require low-voltage ride-through (LVRT capability to maintain power system stability and reliability during grid fault conditions. To meet the LVRT requirement, wind power systems must stay connected to the grid and also supply reactive currents to the grid to support the recovery from fault voltages. This paper presents a new fault detection method and inverter control scheme to improve the LVRT capability for full-scale permanent magnet synchronous generator (PMSG wind power systems. Fast fault detection can help the wind power systems maintain the DC-link voltage in a safe region. The proposed fault detection method is based on on-line adaptive parameter estimation. The performance of the proposed method is verified in comparison to the conventional voltage measurement method defined in the IEC 61400-21 standard.

  9. Synchronization method for grid integrated battery storage systems during asymmetrical grid faults

    Directory of Open Access Journals (Sweden)

    Popadić Bane

    2017-01-01

    Full Text Available This paper aims at presenting a robust and reliable synchronization method for battery storage systems during asymmetrical grid faults. For this purpose, a Matlab/Simulink based model for testing of the power electronic interface between the grid and the battery storage systems has been developed. The synchronization method proposed in the paper is based on the proportional integral resonant controller with the delay signal cancellation. The validity of the synchronization method has been verified using the advanced laboratory station for the control of grid connected distributed energy sources. The proposed synchronization method has eliminated unfavourable components from the estimated grid angular frequency, leading to the more accurate and reliable tracking of the grid voltage vector positive sequence during both the normal operation and the operation during asymmetrical grid faults. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. III 042004: Integrated and Interdisciplinary Research entitled: Smart Electricity Distribution Grids Based on Distribution Management System and Distributed Generation

  10. Contribution of domestic heating systems to smart grid control

    DEFF Research Database (Denmark)

    Tahersima, Fatemeh; Stoustrup, Jakob; Meybodi, Soroush Afkhami

    2011-01-01

    How and to what extent, domestic heating systems can be helpful in regaining power balance in a smart grid, is the question to be answered in this paper. Our case study is an under-floor heating system supplied with a geothermal heat pump which is driven by electrical power from the grid. The idea...... is to deviate power consumption of the heat pump from its optimal value, in order to compensate power imbalances in the grid. Heating systems could be forced to consume energy, i.e. storing it in heat buffers when there is a power surplus in the grid; and be prevented from using power, in case of power shortage...

  11. The Earth System Grid Federation (ESGF) Project

    Science.gov (United States)

    Carenton-Madiec, Nicolas; Denvil, Sébastien; Greenslade, Mark

    2015-04-01

    The Earth System Grid Federation (ESGF) Peer-to-Peer (P2P) enterprise system is a collaboration that develops, deploys and maintains software infrastructure for the management, dissemination, and analysis of model output and observational data. ESGF's primary goal is to facilitate advancements in Earth System Science. It is an interagency and international effort led by the US Department of Energy (DOE), and co-funded by National Aeronautics and Space Administration (NASA), National Oceanic and Atmospheric Administration (NOAA), National Science Foundation (NSF), Infrastructure for the European Network of Earth System Modelling (IS-ENES) and international laboratories such as the Max Planck Institute for Meteorology (MPI-M) german Climate Computing Centre (DKRZ), the Australian National University (ANU) National Computational Infrastructure (NCI), Institut Pierre-Simon Laplace (IPSL), and the British Atmospheric Data Center (BADC). Its main mission is to support current CMIP5 activities and prepare for future assesments. The ESGF architecture is based on a system of autonomous and distributed nodes, which interoperate through common acceptance of federation protocols and trust agreements. Data is stored at multiple nodes around the world, and served through local data and metadata services. Nodes exchange information about their data holdings and services, trust each other for registering users and establishing access control decisions. The net result is that a user can use a web browser, connect to any node, and seamlessly find and access data throughout the federation. This type of collaborative working organization and distributed architecture context en-lighted the need of integration and testing processes definition to ensure the quality of software releases and interoperability. This presentation will introduce the ESGF project and demonstrate the range of tools and processes that have been set up to support release management activities.

  12. Security Challenges in Smart-Grid Metering and Control Systems

    Directory of Open Access Journals (Sweden)

    Xinxin Fan

    2013-07-01

    Full Text Available The smart grid is a next-generation power system that is increasingly attracting the attention of government, industry, and academia. It is an upgraded electricity network that depends on two-way digital communications between supplier and consumer that in turn give support to intelligent metering and monitoring systems. Considering that energy utilities play an increasingly important role in our daily life, smart-grid technology introduces new security challenges that must be addressed. Deploying a smart grid without adequate security might result in serious consequences such as grid instability, utility fraud, and loss of user information and energy-consumption data. Due to the heterogeneous communication architecture of smart grids, it is quite a challenge to design sophisticated and robust security mechanisms that can be easily deployed to protect communications among different layers of the smart grid-infrastructure. In this article, we focus on the communication-security aspect of a smart-grid metering and control system from the perspective of cryptographic techniques, and we discuss different mechanisms to enhance cybersecurity of the emerging smart grid. We aim to provide a comprehensive vulnerability analysis as well as novel insights on the cybersecurity of a smart grid.

  13. Smart Grid Research: Control Systems - IEEE Vision for Smart Grid Controls

    DEFF Research Database (Denmark)

    Aho, Jacob; Arnold, George; Buckspan, Andrew

    This document highlights the role of control systems in the evolution of the Smart Grid. It includes an overview of research investigations that are needed for renewable integration, reliability, self-healing, energy efficiency, and resilience to physical and cyber attacks. These investigations......, and security. Together, they usher in new horizons for control, such as architecting a system of distributed systems, building interfaces to social sciences such as economics, sociology, and psychology, and providing a blueprint for critical infrastructure systems. While the emerging role of control and its...... implication on grid architectures have been articulated in various papers, a comprehensive discourse on the evolution of Smart Grid and the opportunities and challenges that it presents for control, ranging from generators to consumers, from planning to real-time operation, from current practice to scenarios...

  14. Energy Systems Integration: Demonstrating Distributed Grid-Edge Control Hierarchy

    Energy Technology Data Exchange (ETDEWEB)

    2017-01-01

    Overview fact sheet about the OMNETRIC Group Integrated Network Testbed for Energy Grid Research and Technology Experimentation (INTEGRATE) project at the Energy Systems Integration Facility. INTEGRATE is part of the U.S. Department of Energy's Grid Modernization Initiative.

  15. Intelligent Control for a DC Micro-Grid System

    DEFF Research Database (Denmark)

    Martino, Michele; Quiñones, Yamshid Farhat; Raboni, Pietro

    2012-01-01

    This paper presents the dynamic response of a DC–micro-grid (DC-MG) controlled in master-slave mode. The benefits of the micro-grids (MGs) are the low cost in terms of power electronics converters and the high reliability and quality, even in case of loss connection to the transmission system. A DC...

  16. Towards an actor-driven workflow management system for Grids

    NARCIS (Netherlands)

    F. Berretz; S. Skorupa; V. Sander; A. Belloum

    2010-01-01

    Currently, most workflow management systems in Grid environments provide push-oriented job distribution strategies, where jobs are explicitly delegated to resources. In those scenarios the dedicated resources execute submitted jobs according to the request of a workflow engine or Grid wide scheduler

  17. Energy Systems Integration: Demonstrating the Grid Benefits of Connected Devices

    Energy Technology Data Exchange (ETDEWEB)

    2017-01-01

    Overview fact sheet about the Electric Power Research Institute (EPRI) and the University of Delaware Integrated Network Testbed for Energy Grid Research and Technology Experimentation (INTEGRATE) project at the Energy Systems Integration Facility. INTEGRATE is part of the U.S. Department of Energy's Grid Modernization Initiative.

  18. Towards an actor-driven workflow management system for Grids

    NARCIS (Netherlands)

    Berretz, F.; Skorupa, S.; Sander, V.; Belloum, A.

    2010-01-01

    Currently, most workflow management systems in Grid environments provide push-oriented job distribution strategies, where jobs are explicitly delegated to resources. In those scenarios the dedicated resources execute submitted jobs according to the request of a workflow engine or Grid wide

  19. Towards an actor-driven workflow management system for Grids

    NARCIS (Netherlands)

    Berretz, F.; Skorupa, S.; Sander, V.; Belloum, A.

    2010-01-01

    Currently, most workflow management systems in Grid environments provide push-oriented job distribution strategies, where jobs are explicitly delegated to resources. In those scenarios the dedicated resources execute submitted jobs according to the request of a workflow engine or Grid wide scheduler

  20. Network resource control for grid workflow management systems

    NARCIS (Netherlands)

    Strijkers, R.J.; Cristea, M.; Korkhov, V.; Marchal, D.; Belloum, A.; Laat, C.de; Meijer, R.J.

    2010-01-01

    Grid workflow management systems automate the orchestration of scientific applications with large computational and data processing needs, but lack control over network resources. Consequently, the management system cannot prevent multiple communication intensive applications to compete for network

  1. Grid Integration Science, NREL Power Systems Engineering Center

    Energy Technology Data Exchange (ETDEWEB)

    Kroposki, Benjamin [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-04-25

    This report highlights journal articles published in 2016 by researchers in the Power Systems Engineering Center. NREL's Power Systems Engineering Center published 47 journal and magazine articles in the past year, highlighting recent research in grid modernization.

  2. Improved Grid Synchronization Algorithm for DG System using DSRF PLL under Grid disturbances

    Directory of Open Access Journals (Sweden)

    R.Godha

    2014-11-01

    Full Text Available Distributed Generation (DG System is a small scale electric power generation at or near the user’s facility as opposed to the normal mode of centralized power generation. In order to ensure safe and reliable operation of power system based on DS, grid synchronization algorithm plays a very important role. This paper presents a Double Synchronous Reference Frame (DSRF phase locked loop (PLL based on synthesis circuit for grid synchronization of distributed generation (DG system under grid disturbances aimed to provide an estimation of the angular frequency and both the positive and negative sequences of the fundamental component of an unbalanced three-phase signal. The design of this PLL is based on a complete description of the source voltage involving both positive and negative sequences in stationary coordinates and considering the angular frequency as an uncertain parameter.

  3. Communication Systems for Grid Integration of Renewable Energy Resources

    CERN Document Server

    Yu, F Richard; Xiao, Weidong; Choudhury, Paul

    2011-01-01

    There is growing interest in renewable energy around the world. Since most renewable sources are intermittent in nature, it is a challenging task to integrate renewable energy resources into the power grid infrastructure. In this grid integration, communication systems are crucial technologies, which enable the accommodation of distributed renewable energy generation and play extremely important role in monitoring, operating, and protecting both renewable energy generators and power systems. In this paper, we review some communication technologies available for grid integration of renewable energy resources. Then, we present the communication systems used in a real renewable energy project, Bear Mountain Wind Farm (BMW) in British Columbia, Canada. In addition, we present the communication systems used in Photovoltaic Power Systems (PPS). Finally, we outline some research challenges and possible solutions about the communication systems for grid integration of renewable energy resources.

  4. Research of the grid computing system applied in optical simulation

    Science.gov (United States)

    Jin, Wei-wei; Wang, Yu-dong; Liu, Qiangsheng; Cen, Zhao-feng; Li, Xiao-tong; Lin, Yi-qun

    2008-03-01

    A grid computing in the field of optics is presented in this paper. Firstly, the basic principles and research background of grid computing are outlined in this paper, along with the overview of its applications and the development status quo. The paper also discusses several typical tasks scheduling algorithms. Secondly, it focuses on describing a task scheduling of grid computing applied in optical computation. The paper gives details about the task scheduling system, including the task partition, granularity selection and tasks allocation, especially the structure of the system. In addition, some details of communication on grid computing are also illustrated. In this system, the "makespan" and "load balancing" are comprehensively considered. Finally, we build a grid model to test the task scheduling strategy, and the results are analyzed in detail. Compared to one isolated computer, a grid comprised of one server and four processors can shorten the "makespan" to 1/4. At the same time, the experimental results of the simulation also illustrate that the proposed scheduling system is able to balance loads of all processors. In short, the system performs scheduling well in the grid environment.

  5. Grid Information Security Functional Requirement - Fulfilling Information Security of a Smart Grid System

    CERN Document Server

    Ling, Amy Poh Ai; 10.5121/ijgca.2011.2201

    2011-01-01

    This paper describes the background of smart information infrastructure and the needs for smart grid information security. It introduces the conceptual analysis to the methodology with the application of hermeneutic circle and information security functional requirement identification. Information security for the grid market cover matters includes automation and communications industry that affects the operation of electric power systems and the functioning of the utilities that manage them and its awareness of this information infrastructure has become critical to the reliability of the power system. Community benefits from of cost savings, flexibility and deployment along with the establishment of wireless communications. However, concern revolves around the security protections for easily accessible devices such as the smart meter and the related communications hardware. On the other hand, the changing points between traditional versus smart grid networking trend and the information security importance on...

  6. Performance analysis of a grid-connected photovoltaic system

    Energy Technology Data Exchange (ETDEWEB)

    Sidrach-de-Cardona, M. [Universidad de Malaga (Spain). Dpto. Fisica Aplicado II; Lopez, L.M. [Universidad de Malaga (Spain). Dpto. Lenguajes y C. Computacion

    1999-02-01

    Grid-connected photovoltaic systems are required to introduce photovoltaic solar energy into urban areas. To analyze these systems, a 2.0 kW{sub p} power system has been installed at the University of Malaga, Spain. The array power output was estimated by using measured I-V curves for the installed modules with minimization of mismatch losses. The supplied grid energy and main performances are described. The effects on system yield of threshold-inverter and coupling losses of the inverter to the grid have been studied. During 1997, the system supplied 2678 kWh to the grid, i.e. the mean daily output, was 7.4 kWh. The annual performance ratio was 64.5% and the optimal value 67.9%. (author)

  7. Low-voltage grid-connection of photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Collinson, A.; Thornycroft, J.

    1999-07-01

    This report summarises the results of a project aimed at developing technical guidelines concerning grid connected photovoltaic (PV) inverter generators which are to be published in draft form as the {sup U}K Technical Guidelines for Inverter Connected Single Phase Photovoltaic (PV) Generators up to 5kVA{sup .} The background to the use of PV in the UK is traced, and the technical criteria for electrical integration of PV systems, and UK guidelines for grid connected PV systems are examined. The findings of the working group of the International Energy Agency (IEA) Implementing Agreement on Photovoltaic Power Systems are also presented in this report. Appendices discuss the UK technical guidelines, the IEA Task V activities,, utility aspects of grid-connected PV systems, and demonstration tests on grid-connected PV systems, and lists Task V reports.

  8. A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions

    DEFF Research Database (Denmark)

    Rodríguez, P.; Luna, A.; Muñoz-Aguilar, R. S.

    2012-01-01

    Grid synchronization algorithms are of great importance in the control of grid-connected power converters, as fast and accurate detection of the grid voltage parameters is crucial in order to implement stable control strategies under generic grid conditions. This paper presents a new grid...... of the instantaneous symmetrical components of the grid voltage under unbalanced and distorted grid conditions. This paper analyzes the performance of the proposed synchronization method including different design issues. Moreover, the behavior of the method for synchronizing with highly unbalanced grid is proven...

  9. A Guidebook on Grid Interconnection and Islanded Operation of Mini-Grid Power Systems Up to 200 kW

    Energy Technology Data Exchange (ETDEWEB)

    Greacen, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Engel, Richard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Quetchenbach, Thomas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-04-01

    A Guidebook on Grid Interconnection and Islanded Operation of Mini-Grid Power Systems Up to 200 kW is intended to help meet the widespread need for guidance, standards, and procedures for interconnecting mini-grids with the central electric grid as rural electrification advances in developing countries, bringing these once separate power systems together. The guidebook aims to help owners and operators of renewable energy mini-grids understand the technical options available, safety and reliability issues, and engineering and administrative costs of different choices for grid interconnection. The guidebook is intentionally brief but includes a number of appendices that point the reader to additional resources for indepth information. Not included in the scope of the guidebook are policy concerns about “who pays for what,” how tariffs should be set, or other financial issues that are also paramount when “the little grid connects to the big grid.”

  10. Suomi NPP Ground System Performance

    Science.gov (United States)

    Grant, K. D.; Bergeron, C.

    2013-12-01

    The National Oceanic and Atmospheric Administration (NOAA) and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation civilian weather and environmental satellite system: the Joint Polar Satellite System (JPSS). JPSS will replace the afternoon orbit component and ground processing system of the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA. The JPSS satellites will carry a suite of sensors designed to collect meteorological, oceanographic, climatological and geophysical observations of the Earth. The first satellite in the JPSS constellation, known as the Suomi National Polar-orbiting Partnership (Suomi NPP) satellite, was launched on 28 October 2011, and is currently undergoing product calibration and validation activities. As products reach a beta level of maturity, they are made available to the community through NOAA's Comprehensive Large Array-data Stewardship System (CLASS). CGS's data processing capability processes the satellite data from the Joint Polar Satellite System satellites to provide environmental data products (including Sensor Data Records (SDRs) and Environmental Data Records (EDRs)) to NOAA and Department of Defense (DoD) processing centers operated by the United States government. CGS is currently processing and delivering SDRs and EDRs for Suomi NPP and will continue through the lifetime of the Joint Polar Satellite System programs. Following the launch and sensor activation phase of the Suomi NPP mission, full volume data traffic is now flowing from the satellite through CGS's C3, data processing, and data delivery systems. Ground system performance is critical for this operational system. As part of early system checkout, Raytheon measured all aspects of data acquisition, routing, processing, and delivery to ensure operational performance requirements are met, and will continue to be met throughout the mission. Raytheon developed a tool to measure, categorize, and

  11. An Interactive Energy System with Grid, Heating and Transportation Systems

    DEFF Research Database (Denmark)

    Diaz de Cerio Mendaza, Iker

    is required. The models developed in this thesis include different features (thermal, mechanical, chemical…) which are not normally considered in the traditional power system modelling. In this sense, they are intended to serve as a reference for the new researchers starting in the field. Moreover, the grid......: thermostatic loads (electric water heaters and heat pumps), loads for hydrogen generation (alkaline electrolyzers) and load for electric mobility (plug-in and vehicle-to-grid concepts). Many of these are considered domestic loads and they fulfill certain need to the household they belong. Depending on the user...... requirements, these may perform a different power consumption patterns. In this context, the thermal comfort or mobility needs from Danish users are statistically analyzed. The outcome is used to generate random profiles that define the different thermal and mobility requirements from the users of a network...

  12. Grid-connected inverter for wind power generation system

    Institute of Scientific and Technical Information of China (English)

    YANG Yong; RUAN Yi; SHEN Huan-qing; TANG Yan-yan; YANG Ying

    2009-01-01

    In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on PI-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.

  13. Eastern Cape hybrid mini-grid systems - a case study

    CSIR Research Space (South Africa)

    Szewczuk, S

    2010-05-01

    Full Text Available -GRID SYSTEMS A CASE STUDY WIND POWER AFRICA 2010 S Szewczuk CSIR May 2010 PRESENTATION OUTLINE • Rationale for Projects • Renewable Energy for Rural Electrification in E Cape • Integrated Energy/Economic Framework • Hybrid mini-grid energy systems... • Impact of research work RATIONALE FOR OFF-GRID PROJECTS • Poverty Reduction: • Sustainable economic and social benefits • Meeting of Millennium Development Goals • Appropriate technology choice: • 500 million African people without access to modern...

  14. Preface: Workshop on Off-Grid Technology Systems

    Science.gov (United States)

    Alonso-Marroquin, Fernando

    2017-06-01

    Off-grid houses are dwellings that do not rely on water supply, sewer, or electrical power grid, and are able to operate independently of all public utility services. These houses are ideal for remote communities or population suffering natural or human-made disasters. Our aim is to develop compact and affordable off-grid technologies by integrating high-end nano-engineering with systems that imitates natural biological processes. The key areas of focus in the workshop were: solar energy harvesting using nanotechnology, wind energy harvesting from vertical-axis wind turbines, supercapacitors energy storage systems, treatment of greywater, and green roofs to achieve air comfort.

  15. Electric grid stability and the design of sustainable energy systems

    DEFF Research Database (Denmark)

    Lund, Henrik

    2005-01-01

    The article presents technical designs of potential future flexible energy systems, which will be able both to balance production and demand and to secure voltage and frequency requirements on the grid....

  16. ESIF 2016: Modernizing Our Grid and Energy System

    Energy Technology Data Exchange (ETDEWEB)

    Van Becelaere, Kimberly [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-03-09

    This 2016 annual report highlights work conducted at the Energy Systems Integration Facility (ESIF) in FY 2016, including grid modernization, high-performance computing and visualization, and INTEGRATE projects.

  17. Smart grid and renewable energy systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Guerrero, Josep M.

    2011-01-01

    The electrical energy consumption continues growing and more applications relay on electricity. We can expect that more 60 % of all energy consumption will be converted and used as electricity. Therefore, it is a demand that production, distribution and use of electrical energy are done as effici...... sources, wind energy and photovoltaics. Then main focus is on the power electronics and control technology for wind turbines as they are the largest renewable power contributor, allowing their penetration into a SmartGrid to be even higher in the future....... conventional, fossil based energy sources to renewable energy sources. Another is to use high efficient power electronics in power generation, power transmission/distribution and end-user application. This paper discus trends of the future grid infrastructure as well as the most emerging renewable energy...

  18. Advanced Ground Systems Maintenance Anomaly Detection Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop the capability to identify anomalous conditions (indications to potential impending system failure) in ground system operations before such...

  19. Smart Grid Research: Control Systems - IEEE Vision for Smart Grid Controls

    DEFF Research Database (Denmark)

    Aho, Jacob; Arnold, George; Buckspan, Andrew

    This document highlights the role of control systems in the evolution of the Smart Grid. It includes an overview of research investigations that are needed for renewable integration, reliability, self-healing, energy efficiency, and resilience to physical and cyber attacks. These investigations...... are encapsulated in several loci of control including: new methodologies for transmission, distribution, and renewable energy, and storage; new roles in emerging topics such as electricity markets, demand-response, microgrids, and virtual power plants; and new solutions for efficiency, heating and cooling...... implication on grid architectures have been articulated in various papers, a comprehensive discourse on the evolution of Smart Grid and the opportunities and challenges that it presents for control, ranging from generators to consumers, from planning to real-time operation, from current practice to scenarios...

  20. New grid-planning and certification approaches for the large-scale offshore-wind farm grid-connection systems

    Energy Technology Data Exchange (ETDEWEB)

    Heising, C.; Bartelt, R. [Avasition GmbH, Dortmund (Germany); Zadeh, M. Koochack; Lebioda, T.J.; Jung, J. [TenneT Offshore GmbH, Bayreuth (Germany)

    2012-07-01

    Stable operation of the offshore-wind farms (OWF) and stable grid connection under stationary and dynamic conditions are essential to achieve a stable public power supply. To reach this aim, adequate grid-planning and certification approaches are a major advantage. Within this paper, the fundamental characteristics of the offshore-wind farms and their grid-connection systems are given. The main goal of this research project is to study the stability of the offshore grid especially in terms of subharmonic stability for the likely future extension stage of the offshore grids i.e. having parallel connection of two or more HVDC links and for certain operating scenarios e.g. overload scenario. The current requirements according to the grid code are not the focus of this research project. The goal is to study and define potential additional grid code requirements, simulations, tests and grid planning methods for the future. (orig.)

  1. Hardware-in-the-loop grid simulator system and method

    Science.gov (United States)

    Fox, John Curtiss; Collins, Edward Randolph; Rigas, Nikolaos

    2017-05-16

    A hardware-in-the-loop (HIL) electrical grid simulation system and method that combines a reactive divider with a variable frequency converter to better mimic and control expected and unexpected parameters in an electrical grid. The invention provides grid simulation in a manner to allow improved testing of variable power generators, such as wind turbines, and their operation once interconnected with an electrical grid in multiple countries. The system further comprises an improved variable fault reactance (reactive divider) capable of providing a variable fault reactance power output to control a voltage profile, therein creating an arbitrary recovery voltage. The system further comprises an improved isolation transformer designed to isolate zero-sequence current from either a primary or secondary winding in a transformer or pass the zero-sequence current from a primary to a secondary winding.

  2. GENIE(++): A Multi-Block Structured Grid System

    Science.gov (United States)

    Williams, Tonya; Nadenthiran, Naren; Thornburg, Hugh; Soni, Bharat K.

    1996-01-01

    The computer code GENIE++ is a continuously evolving grid system containing a multitude of proven geometry/grid techniques. The generation process in GENIE++ is based on an earlier version. The process uses several techniques either separately or in combination to quickly and economically generate sculptured geometry descriptions and grids for arbitrary geometries. The computational mesh is formed by using an appropriate algebraic method. Grid clustering is accomplished with either exponential or hyperbolic tangent routines which allow the user to specify a desired point distribution. Grid smoothing can be accomplished by using an elliptic solver with proper forcing functions. B-spline and Non-Uniform Rational B-splines (NURBS) algorithms are used for surface definition and redistribution. The built in sculptured geometry definition with desired distribution of points, automatic Bezier curve/surface generation for interior boundaries/surfaces, and surface redistribution is based on NURBS. Weighted Lagrance/Hermite transfinite interpolation methods, interactive geometry/grid manipulation modules, and on-line graphical visualization of the generation process are salient features of this system which result in a significant time savings for a given geometry/grid application.

  3. Monitoring and Analysis of Two Grid Connected PV Systems

    OpenAIRE

    2013-01-01

    International audience; In this paper, two grid connected photovoltaic systems are studied and monitored for fault detection ad predictive reliability. The first PV grid, is at CNRS-PROMES laboratory in Perpignan, built in 2001 with 3 PV arrays named "Shed","Brise soleil","Mur rideau") connected to the grid thanks to many inverter of different power (3 of 4KWC and 2 of 2.5KWC). The second one is at CNRS-LAAS in Toulouse with a power of 100kWc. It is composed of a facade of 36kWc PV array and ...

  4. The Geographic Information Grid System Based on Mobile Agent

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    We analyze the deficiencies of current application systems, and discuss the key requirements of distributed Geographic Information service (GIS). We construct the distributed GIS on grid platform. Considering the flexibility and efficiency, we integrate the mobile agent technology into the system. We propose a new prototype system, the Geographic Information Grid System (GIGS) based on mobile agent. This system has flexible services and high performance, and improves the sharing of distributed resources. The service strategy of the system and the examples are also presented.

  5. Performance Analyses of IDEAL Algorithm on Highly Skewed Grid System

    Directory of Open Access Journals (Sweden)

    Dongliang Sun

    2014-03-01

    Full Text Available IDEAL is an efficient segregated algorithm for the fluid flow and heat transfer problems. This algorithm has now been extended to the 3D nonorthogonal curvilinear coordinates. Highly skewed grids in the nonorthogonal curvilinear coordinates can decrease the convergence rate and deteriorate the calculating stability. In this study, the feasibility of the IDEAL algorithm on highly skewed grid system is analyzed by investigating the lid-driven flow in the inclined cavity. It can be concluded that the IDEAL algorithm is more robust and more efficient than the traditional SIMPLER algorithm, especially for the highly skewed and fine grid system. For example, at θ = 5° and grid number = 70 × 70 × 70, the convergence rate of the IDEAL algorithm is 6.3 times faster than that of the SIMPLER algorithm, and the IDEAL algorithm can converge almost at any time step multiple.

  6. Architecture and key technologies of grid geographic information system

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    The highly efficient and stable collaborative computation platform for geospatial information can be constructed on the basis of Grid computing technology,com-bined with Peer-to-Peer (P2P) computing technology and geospatial database technology. This paper proposed the architecture and key technologies of the Grid GIS (Geographic Information System) incorporated with P2P structure,and corre-spondingly a Grid GIS prototype named Nebula was designed and then imple-mented. Nebula is a suite of middleware for geospatial Grid computing,which could be deployed onto various service nodes in network. Based on Grid protocols and infrastructure,Nebula provides invocation interfaces to users in form of Grid services. By using P2P message based communication mechanism,complex geospatial computation tasks could be accomplished by Nebula in a collaborative way. This paper introduced Nebula’s architecture and key modules,and according to experimental data,we discussed the Grid GIS’s advantages,application scenar-ios and future directions.

  7. Driving Energy System Transformation with "Vehicle-to-Grid" Power

    OpenAIRE

    Moura, F

    2006-01-01

    Today's electricity and transport systems face a number of challenges related to reliability, security and environmental sustainability. New technologies may provide a means by which to overcome some of these challenges, yet many such technologies are confronted with substantial technical or commercial hurdles. This report explores one promising technology, "Vehicle-to-Grid" (V2G) power generation, whereby parked Electric-Drive Vehicles (EDVs) are used to provide electricity to the grid. EDV...

  8. A Taxonomy of Workflow Management Systems for Grid Computing

    OpenAIRE

    Yu, Jia; Buyya, Rajkumar

    2005-01-01

    With the advent of Grid and application technologies, scientists and engineers are building more and more complex applications to manage and process large data sets, and execute scientific experiments on distributed resources. Such application scenarios require means for composing and executing complex workflows. Therefore, many efforts have been made towards the development of workflow management systems for Grid computing. In this paper, we propose a taxonomy that characterizes and classifi...

  9. Ground Collision Avoidance System (Igcas)

    Science.gov (United States)

    Skoog, Mark A (Inventor); Prosser, Kevin (Inventor); Hook, Loyd (Inventor)

    2017-01-01

    The present invention is a system and method for aircraft ground collision avoidance (iGCAS) comprising a modular array of software, including a sense own state module configured to gather data to compute trajectory, a sense terrain module including a digital terrain map (DTM) and map manger routine to store and retrieve terrain elevations, a predict collision threat module configured to generate an elevation profile corresponding to the terrain under the trajectory computed by said sense own state module, a predict avoidance trajectory module configured to simulate avoidance maneuvers ahead of the aircraft, a determine need to avoid module configured to determine which avoidance maneuver should be used, when it should be initiated, and when it should be terminated, a notify Module configured to display each maneuver's viability to the pilot by a colored GUI, a pilot controls module configured to turn the system on and off, and an avoid module configured to define how an aircraft will perform avoidance maneuvers through 3-dimensional space.

  10. Design of smart power grid renewable energy systems

    CERN Document Server

    Keyhani, Ali

    2011-01-01

    To address the modeling and control of smart grid renewable energy system into electric power systems, this book integrates three areas of electrical engineering: power system engineering, control systems engineering and power electronics  The approach to the integration of these three areas differs from classical methods. Due to complexity of this task, the author has decided to present the basic concepts, and then present a simulation test bed in matlab to use these concepts to solve a basic problem in development of smart grid energy system. Therefore, each chapter has three parts: first a

  11. Simple system for locating ground loops.

    Science.gov (United States)

    Bellan, P M

    2007-06-01

    A simple low-cost system for rapid identification of the cables causing ground loops in complex instrumentation configurations is described. The system consists of an exciter module that generates a 100 kHz ground loop current and a detector module that determines which cable conducts this test current. Both the exciter and detector are magnetically coupled to the ground circuit so there is no physical contact to the instrumentation system under test.

  12. A Machine Vision System for Ball Grid Array Package Inspection

    Institute of Scientific and Technical Information of China (English)

    XIA Nian-jiong; CAO Qi-xin; LEE Jey

    2005-01-01

    An optical inspection method of the Ball Grid Array package (BGA) was proposed by using a machine vision system. The developed machine vision system could get main critical factors for BGA quality evaluation, such as the height of solder ball, diameter, pitch and coplanarity. The experiment has proved that this system is available for BGA failure detection.

  13. Overview of Single-Phase Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Blaabjerg, Frede

    2015-01-01

    A still booming installation of solar photovoltaic (PV) systems has been witnessed worldwide. It is mainly driven by the demand of “clean” power generation. Grid-connected PV systems will become an even active player in the future mixed power systems, which are linked by a vast of power electronics...

  14. Grid-connected PV systems - How and where they fit

    Science.gov (United States)

    Thomas, M. G.; Jones, G. J.

    The use of grid-connected photovoltaic systems requires substantial improvements in system economics. By integrating anticipated improvements in economics with consumer needs and perceptions, the various potential applications have been order-ranked. Third-party ownership of large systems appears to have the largest potential, residential has a modest potential, and the intermediate dedicated-load application potential appears to be small.

  15. Grid-connected photovoltaic (PV) systems with batteries storage as solution to electrical grid outages in Burkina Faso

    Science.gov (United States)

    Abdoulaye, D.; Koalaga, Z.; Zougmore, F.

    2012-02-01

    This paper deals with a key solution for power outages problem experienced by many African countries and this through grid-connected photovoltaic (PV) systems with batteries storage. African grids are characterized by an insufficient power supply and frequent interruptions. Due to this fact, users who especially use classical grid-connected photovoltaic systems are unable to profit from their installation even if there is sun. In this study, we suggest the using of a grid-connected photovoltaic system with batteries storage as a solution to these problems. This photovoltaic system works by injecting the surplus of electricity production into grid and can also deliver electricity as a stand-alone system with all security needed. To achieve our study objectives, firstly we conducted a survey of a real situation of one African electrical grid, the case of Burkina Faso (SONABEL: National Electricity Company of Burkina). Secondly, as study case, we undertake a sizing, a modeling and a simulation of a grid-connected PV system with batteries storage for the LAME laboratory at the University of Ouagadougou. The simulation shows that the proposed grid-connected system allows users to profit from their photovoltaic installation at any time even if the public electrical grid has some failures either during the day or at night.

  16. 46 CFR 183.376 - Grounded distribution systems (neutral grounded).

    Science.gov (United States)

    2010-10-01

    ... propulsion, power, lighting, or distribution system having a neutral bus or conductor must have the neutral..., circuit breaker, or fuse in the neutral conductor of the bus-tie feeder connecting the emergency... that aluminum grounding conductors must not be used....

  17. Energy storage systems: power grid and energy market use cases

    Directory of Open Access Journals (Sweden)

    Komarnicki Przemysław

    2016-09-01

    Full Text Available Current power grid and market development, characterized by large growth of distributed energy sources in recent years, especially in Europa, are according energy storage systems an increasingly larger field of implementation. Existing storage technologies, e.g. pumped-storage power plants, have to be upgraded and extended by new but not yet commercially viable technologies (e.g. batteries or adiabatic compressed air energy storage that meet expected demands. Optimal sizing of storage systems and technically and economically optimal operating strategies are the major challenges to the integration of such systems in the future smart grid. This paper surveys firstly the literature on the latest niche applications. Then, potential new use case and operating scenarios for energy storage systems in smart grids, which have been field tested, are presented and discussed and subsequently assessed technically and economically.

  18. Scheduling in Desktop Grid Systems: Theoretical Evaluation of Policies & Frameworks

    Directory of Open Access Journals (Sweden)

    Muhammad Khalid Khan

    2017-01-01

    Full Text Available Desktop grid systems have already established their identity in the area of distributed systems. They are well suited for High Throughput Computing especially for Bag-of-Tasks applications. In desktop grid systems, idle processing cycles and memory of millions of users (connected through internet or through any other communication mechanism can be utilized but the workers / hosts machines not under any centralized administrative control that result in high volatility. This issue is countered by applying various types of scheduling policies that not only ensure task assignments to better workers but also takes care of fault tolerance through replication and other mechanism. In this paper, we discussed leading desktop grid systems framework and performed a comparative analysis of these frameworks. We also presented a theoretical evaluation of server and client based scheduling policies and identified key performance indicators to evaluate these policies.

  19. Cyber physical systems approach to smart electric power grid

    CERN Document Server

    Khaitan, Siddhartha Kumar; Liu, Chen Ching

    2015-01-01

    This book documents recent advances in the field of modeling, simulation, control, security and reliability of Cyber- Physical Systems (CPS) in power grids. The aim of this book is to help the reader gain insights into working of CPSs and understand their potential in transforming the power grids of tomorrow. This book will be useful for all those who are interested in design of cyber-physical systems, be they students or researchers in power systems, CPS modeling software developers, technical marketing professionals and business policy-makers.

  20. Trends and Potentials of the Smart Grid Infrastructure: From ICT Sub-System to SDN-Enabled Smart Grid Architecture

    Directory of Open Access Journals (Sweden)

    Jaebeom Kim

    2015-10-01

    Full Text Available Context and situational awareness are key features and trends of the smart grid and enable adaptable, flexible and extendable smart grid services. However, the traditional hardware-dependent communication infrastructure is not designed to identify the flow and context of data, and it focuses only on packet forwarding using a pre-defined network configuration profile. Thus, the current network infrastructure may not dynamically adapt the various business models and services of the smart grid system. To solve this problem, software-defined networking (SDN is being considered in the smart grid, but the design, architecture and system model need to be optimized for the smart grid environment. In this paper, we investigate the state-of-the-art smart grid information subsystem, communication infrastructure and its emerging trends and potentials, called an SDN-enabled smart grid. We present an abstract business model, candidate SDN applications and common architecture of the SDN-enabled smart grid. Further, we compare recent studies into the SDN-enabled smart grid depending on its service functionalities, and we describe further challenges of the SDN-enabled smart grid network infrastructure.

  1. Comparing the architecture of Grid Computing and Cloud Computing systems

    Directory of Open Access Journals (Sweden)

    Abdollah Doavi

    2015-09-01

    Full Text Available Grid Computing or computational connected networks is a new network model that allows the possibility of massive computational operations using the connected resources, in fact, it is a new generation of distributed networks. Grid architecture is recommended because the widespread nature of the Internet makes an exciting environment called 'Grid' to create a scalable system with high-performance, generalized and secure. Then the central architecture called to this goal is a firmware named GridOS. The term 'cloud computing' means the development and deployment of Internet –based computing technology. This is a style of computing in an environment where IT-related capabilities offered as a service or users services. And it allows him/her to have access to technology-based services on the Internet; without the user having the specific information about this technology or (s he wants to take control of the IT infrastructure supported by him/her. In the paper, general explanations are given about the systems Grid and Cloud. Then their provided components and services are checked by these systems and their security.

  2. Modernization of the Cassini Ground System

    Science.gov (United States)

    Razo, Gus; Fujii, Tammy

    2014-01-01

    The Cassini Spacecraft and its ground system have been operational for over 16 years. Modernization presents several challenges due to the personnel, processes, and tools already invested and embedded into the current ground system structure. Every mission's ground system has its own unique complexities and challenges, involving various organizational units. As any mission from its inception to its execution, schedules are always tight. This forces GDS engineers to implement a working ground system that is not necessarily fully optimized. Ground system challenges increase as technology evolves and cyber threats become more sophisticated. Cassini's main challenges were due to its ground system existing before many security requirements were levied on the multi-mission tools and networks. This caused a domino effect on Cassini GDS tools that relied on outdated technological features. In the aerospace industry reliable and established technology is preferred over innovative yet less proven technology. Loss of data for a spacecraft mission can be catastrophic; therefore, there is a reluctance to make changes and updates to the ground system. Nevertheless, all missions and associated teams face the need to modernize their processes and tools. Systems development methods from well-known system analysis and design principles can be applied to many missions' ground systems. Modernization should always be considered, but should be done in such a way that it does not affect flexibility nor interfere with established practices. Cassini has accomplished a secure and efficient ground data system through periodic updates. The obstacles faced while performing the modernization of the Cassini ground system will be outlined, as well as the advantages and challenges that were encountered.

  3. Accounting and Accountability for Distributed and Grid Systems

    Science.gov (United States)

    Thigpen, William; McGinnis, Laura F.; Hacker, Thomas J.

    2001-01-01

    While the advent of distributed and grid computing systems will open new opportunities for scientific exploration, the reality of such implementations could prove to be a system administrator's nightmare. A lot of effort is being spent on identifying and resolving the obvious problems of security, scheduling, authentication and authorization. Lurking in the background, though, are the largely unaddressed issues of accountability and usage accounting: (1) mapping resource usage to resource users; (2) defining usage economies or methods for resource exchange; (3) describing implementation standards that minimize and compartmentalize the tasks required for a site to participate in a grid.

  4. Grid converters for photovoltaic and wind power systems

    CERN Document Server

    Teodorescu, Remus; Rodríguez, Pedro

    2011-01-01

    "Grid Converters for Photovoltaic and Wind Power Systems provides a comprehensive description of the control of grid converters for photovoltaic and wind power systems. The authors present a range of control methods for meeting the latest application, power quality and power conversion requirements and standards, as well as looking towards potential future control functions. Practical examples, exercises, and an accompanying website with simulation models using Matlab and Simulink environments, and PSIM software make this text a pragmatic resource for electrical engineers as well as students taking related courses"--

  5. An optimal replication strategy for data grid systems

    Institute of Scientific and Technical Information of China (English)

    JIANG Jianjin; YANG Guangwen

    2007-01-01

    Data access latency is an important metric of system performance in data grid.By means of efficient replication strategy,the amount of data transferred in a wide area network will decrease,and the average access latency of data will decrease ultimately.The motivation of our research is to solve the optimized replica distribution problem in a data grid;that is,the system should utilize many replicas for every data with storage constraints to minimize the average access latency of data.This paper proposes a model of replication strategy in federated data grid and gives the optimized solution.The analysis results and simulation results show that the optimized replication strategy proposed in this paper is superior to LRU caching strategy,uniform replication strategy,proportional replication strategy and square root replication strategy in terms of wide area network bandwidth requirement and in the average access latency of data.

  6. A System for Monitoring and Management of Computational Grids

    Science.gov (United States)

    Smith, Warren; Biegel, Bryan (Technical Monitor)

    2002-01-01

    As organizations begin to deploy large computational grids, it has become apparent that systems for observation and control of the resources, services, and applications that make up such grids are needed. Administrators must observe the operation of resources and services to ensure that they are operating correctly and they must control the resources and services to ensure that their operation meets the needs of users. Users are also interested in the operation of resources and services so that they can choose the most appropriate ones to use. In this paper we describe a prototype system to monitor and manage computational grids and describe the general software framework for control and observation in distributed environments that it is based on.

  7. Grid Converters for Stationary Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Trintis, Ionut

    to hours, rated at MW and MWh, battery energy storage systems are suitable and ecient solutions. Grid connection of the storage system can be done at dierent voltage levels, depending on the location and application scenario. For high power and energy ratings, increase in the battery and converter voltage...... was realized for a 100 kW active rectier to be used in a 6 kV battery energy storage test bench. In the second part, dierent solutions for power converters to interface energy storage units to medium voltage grid are given. A new modular multilevel converter concept is introduced, where the energy storage......-voltage 100 kW bidirectional grid converter, to be used in a high voltage battery energy storage test bench. The control structure proved to be stable without damping. The converter was tested in the test bench and the experimental results are presented. Multilevel converters are replacing the classical two...

  8. A distributed spatial computing prototype system in grid environment

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Digital Earth has been a hot topic and research trend since it was proposed,and Digital China has drawn much attention in China.As a key technique to implement Digital China,grid is an excellent and promising concept to construct a dynamic,inter-domain and distributed computing environment.It is appropriate to process geographic information across dispersed computing resources in networks effectively and cooperatively.A distributed spatial computing prototype system is designed and implemented with the Globus Toolkit.Several important aspects are discussed in detail.The architecture is proposed according to the characteristics of grid firstly,and then the spatial resource query and access interfaces are designed for heterogeneous data sources.An open-up hierarchical architecture for resource discovery and management is represented to detect spatial and computing resources in grid.A standard spatial job management mechanism is implemented by grid service for convenient use.In addition,the control mechanism of spatial datasets access is developed based on GSI.The prototype system utilizes the Globus Toolkit to implement a common distributed spatial computing framework,and it reveals the spatial computing ability of grid to support Digital China.

  9. Dynamic Grid Scheduling with Job Migration and Rescheduling in the GridLab Resource Management System

    Directory of Open Access Journals (Sweden)

    K. Kurowski

    2004-01-01

    Full Text Available Grid computing has become one of the most important research topics that appeared in the field of computing in the last years. Simultaneously, we have noticed the growing popularity of new Web-based technologies which allow us to create application-oriented Grid middleware services providing capabilities required for dynamic resource and job management, monitoring, security, etc. Consequently, end users are able to get easier access to geographically distributed resources. In this paper we present the results of our experiments with the Grid(Lab Resource Management System (GRMS, which acts on behalf of end users and controls their computations efficiently using distributed heterogeneous resources. We show how resource matching techniques used within GRMS can be improved by the use of a job migration based rescheduling policy. The main aim of this policy is to shorten job pending times and reduce machine overloads. The influence of this method on application performance and resource utilization is studied in detail and compared with two other simple policies.

  10. Training, simulation, restoration expert system for power grid

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The paper introduces some technology for training, simulation, restoration expert system of power grid, the structure of the system including function composition, hardware and software composition are discussed, knowledge representation and the method to establish device graphical library for expert system are given, the fault setting and diagnosis for training and simulation as well as restoration technology with deep first searching arithmetic and heuristic inference are presented. The research provides a good base for developing the training, simulation, restoration system of power companies.

  11. Grid Integration of Large PV Power Systems Using HVDC Link

    Directory of Open Access Journals (Sweden)

    Gamal Sowilam

    2016-09-01

    Full Text Available This paper explores the interconnection of large scale Photo-Voltaic (PV systems to the grid though a High Voltage Direct Current (HVDC link. HVDC link is recently utilized for transmission lines longer than 50 km. It is usually utilized to interconnect two asynchronous grids with the same or different frequencies while avoiding stability disturbances greatly. A suitable Maximum Power Point Tracking (MPPT techniques is employed to control the performance of the integrated PV system. The system of the HVDC link has two 12-pulse converter using thyristor-bridges. The delay and the extinction angles at the rectifier and the inverter units control the flow and the quantity of the transmitted power from the PV system into the grid. Fixed capacitors and filters are used to provide the AC side with the required reactive power and reduce the harmonic contents. For evaluation purposes, different simulation investigations are carried out with a detailed modeling using the MATLAB. These tests corroborate the efficacy of HVDC link for integrating large PV systems to electrical grids.

  12. OVERSMART Reporting Tool for Flow Computations Over Large Grid Systems

    Science.gov (United States)

    Kao, David L.; Chan, William M.

    2012-01-01

    Structured grid solvers such as NASA's OVERFLOW compressible Navier-Stokes flow solver can generate large data files that contain convergence histories for flow equation residuals, turbulence model equation residuals, component forces and moments, and component relative motion dynamics variables. Most of today's large-scale problems can extend to hundreds of grids, and over 100 million grid points. However, due to the lack of efficient tools, only a small fraction of information contained in these files is analyzed. OVERSMART (OVERFLOW Solution Monitoring And Reporting Tool) provides a comprehensive report of solution convergence of flow computations over large, complex grid systems. It produces a one-page executive summary of the behavior of flow equation residuals, turbulence model equation residuals, and component forces and moments. Under the automatic option, a matrix of commonly viewed plots such as residual histograms, composite residuals, sub-iteration bar graphs, and component forces and moments is automatically generated. Specific plots required by the user can also be prescribed via a command file or a graphical user interface. Output is directed to the user s computer screen and/or to an html file for archival purposes. The current implementation has been targeted for the OVERFLOW flow solver, which is used to obtain a flow solution on structured overset grids. The OVERSMART framework allows easy extension to other flow solvers.

  13. Utility interface issues for grid-connected photovoltaic systems

    Science.gov (United States)

    Chu, D.; Key, T.; Fitzer, J.

    Photovoltaic (PV) balance-of-system research and development has focused on interconnection with the utility grid as the most promising future application for photovoltaic energy production. These sysems must be compatible with the existing utility grid to be accepted. Compatibility encompasses many technical, economic and institutional issues, from lineman safety to revenue metering and power quality. This paper reviews DOE/PV sponsored research for two of the technical interconnection issues: harmonic injection, and power factor control. Explanations and rationale behind these two issues will be reviewed, and the status of current research and plans for required future work will be presented.

  14. Optimal system sizing in grid-connected photovoltaic applications

    Science.gov (United States)

    Simoens, H. M.; Baert, D. H.; de Mey, G.

    A costs/benefits analysis for optimizing the combination of photovoltaic (PV) panels, batteries and an inverter for grid interconnected systems at a 500 W/day Belgian residence is presented. It is assumed that some power purchases from the grid will always be necessary, and that excess PV power can be fed into the grid. A minimal value for the cost divided by the performance is defined for economic optimization. Shortages and excesses are calculated for PV panels of 0.5-10 kWp output, with consideration given to the advantages of a battery back-up. The minimal economic value is found to increase with the magnitude of PV output, and an inverter should never be rated at more than half the array maximum output. A maximum panel size for the Belgian residence is projected to be 6 kWp.

  15. Wind Power - WINDSPD100_IN: Mean Wind Speed at Height of 100 Meters above Ground, Derived from Mesoscale Atmospheric Simulation System and WindMap (TrueWind Solutions, 200-Meter Grid)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — The following is excerpted from an unpublished report by Michael Brower (2004): "Using the MesoMap system, TrueWind has produced maps of mean wind speed in Indiana...

  16. Wind Power - WINDPWR100_IN: Mean Wind Power at Height of 100 Meters above Ground, Derived from Mesoscale Atmospheric Simulation System and WindMap(TrueWind Solutions, 200-Meter Grid)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — The following is excerpted from an unpublished report by Michael Brower (2004): "Using the MesoMap system, TrueWind has produced maps of mean wind speed in Indiana...

  17. Wind Power - WINDSPD50_IN: Mean Wind Speed at Height of 50 Meters above Ground, Derived from Mesoscale Atmospheric Simulation System and WindMap (TrueWind Solutions, 200-Meter Grid)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — The following is excerpted from an unpublished report by Michael Brower (2004): "Using the MesoMap system, TrueWind has produced maps of mean wind speed in Indiana...

  18. Wind Power - WINDPWR50_IN: Mean Wind Power at Height of 50 Meters above Ground, Derived from Mesoscale Atmospheric Simulation System and WindMap (TrueWind Solutions, 200-Meter Grid)

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — The following is excerpted from an unpublished report by Michael Brower (2004): "Using the MesoMap system, TrueWind has produced maps of mean wind speed in Indiana...

  19. A COMPARISON OF INTERCELL METRICS ON DISCRETE GLOBAL GRID SYSTEMS

    Science.gov (United States)

    A discrete global grid system (DGGS) is a spatial data model that aids in global research by serving as a framework for environmental modeling, monitoring and sampling across the earth at multiple spatial scales. Topological and geometric criteria have been proposed to evaluate a...

  20. Establishment of key grid-connected performance index system for integrated PV-ES system

    Science.gov (United States)

    Li, Q.; Yuan, X. D.; Qi, Q.; Liu, H. M.

    2016-08-01

    In order to further promote integrated optimization operation of distributed new energy/ energy storage/ active load, this paper studies the integrated photovoltaic-energy storage (PV-ES) system which is connected with the distribution network, and analyzes typical structure and configuration selection for integrated PV-ES generation system. By combining practical grid- connected characteristics requirements and technology standard specification of photovoltaic generation system, this paper takes full account of energy storage system, and then proposes several new grid-connected performance indexes such as paralleled current sharing characteristic, parallel response consistency, adjusting characteristic, virtual moment of inertia characteristic, on- grid/off-grid switch characteristic, and so on. A comprehensive and feasible grid-connected performance index system is then established to support grid-connected performance testing on integrated PV-ES system.

  1. A Checkpoint Storage System for Desktop Grid Computing

    CERN Document Server

    Kiswany, Samer Al; Vazhkudai, Sudharshan S

    2007-01-01

    Checkpointing is an indispensable technique to provide fault tolerance for long-running high-throughput applications like those running on desktop grids. In these environments, a checkpoint storage system can offer multiple benefits: reduce the load on a traditional file system, offer high-performance through specialization, and, finally, optimize checkpoint data management by taking into account application semantics. Such a storage system can present a unifying abstraction to checkpoint operations, while hiding the fact that there are no dedicated resources to store the checkpoint data. This paper presents a dedicated checkpoint storage system for desktop grid environments. Our solution uses scavenged disk space from participating desktops to build an inexpensive storage space, offering a traditional file system interface for easy integration with checkpointing applications. This paper presents the architecture of our checkpoint storage system, key write optimizations for high-speed I/O, support for increme...

  2. Grid-connected distributed solar power systems

    Science.gov (United States)

    Moyle, R.; Chernoff, H.; Schweizer, T.

    This paper discusses some important, though often ignored, technical and economic issues of distributed solar power systems: protection of the utility system and nonsolar customers requires suitable interfaced equipment. Purchase criteria must mirror reality; most analyses use life-cycle costing with low discount rates - most buyers use short payback periods. Distributing, installing, and marketing small, distributed solar systems is more costly than most analyses estimate. Results show that certain local conditions and uncommon purchase considerations can combine to make small, distributed solar power attractive, but lower interconnect costs (per kW), lower marketing and product distribution costs, and more favorable purchase criteria make large, centralized solar energy more attractive. Specifically, the value of dispersed solar systems to investors and utilities can be higher than $2000/kw. However, typical residential owners place a value of well under $1000 on the installed system.

  3. A policy system for Grid Management and Monitoring

    Science.gov (United States)

    Stagni, Federico; Santinelli, Roberto; LHCb Collaboration

    2011-12-01

    Organizations using a Grid computing model are faced with non-traditional administrative challenges: the heterogeneous nature of the underlying resources requires professionals acting as Grid Administrators. Members of a Virtual Organization (VO) can use a subset of available resources and services in the grid infrastructure and in an ideal world, the more resoures are exploited the better. In the real world, the less faulty services, the better: experienced Grid administrators apply procedures for adding and removing services, based on their status, as it is reported by an ever-growing set of monitoring tools. When a procedure is agreed and well-exercised, a formal policy could be derived. For this reason, using the DIRAC framework in the LHCb collaboration, we developed a policy system that can enforce management and operational policies, in a VO-specific fashion. A single policy makes an assessment on the status of a subject, relative to one or more monitoring information. Subjects of the policies are monitored entities of an established Grid ontology. The status of a same entity is evaluated against a number of policies, whose results are then combined by a Policy Decision Point. Such results are enforced in a Policy Enforcing Point, which provides plug-ins for actions, like raising alarms, sending notifications, automatic addition and removal of services and resources from the Grid mask. Policy results are shown in the web portal, and site-specific views are provided also. This innovative system provides advantages in terms of procedures automation, information aggregation and problem solving.

  4. Application of modified vector fitting to grounding system modeling

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez, D.; Camargo, M.; Herrera, J.; Torres, H. [National University of Colombia (Colombia). Research Program on Acquisition and Analysis of Signals - PAAS], Emails: dyjimeneza@unal.edu.co, mpcamargom@unal.edu.co; Vargas, M. [Siemens S.A. - Power Transmission and Distribution - Energy Services (Colombia)

    2007-07-01

    The transient behavior of grounding systems (GS) influences greatly the performance of electrical networks under fault conditions. This fact has led the authors to present an application of the Modified Vector Fitting (MVF)1 methodology based upon the frequency response of the system, in order to find a rational function approximation and an equivalent electrical network whose transient behavior is similar to the original one of the GS. The obtained network can be introduced into the EMTP/ATP program for simulating the transient behavior of the GS. The MVF technique, which is a modification of the Vector Fitting (VF) technique, allows identifying state space models from the Frequency Domain Response for both single and multiple input-output systems. In this work, the methodology is used to fit the frequency response of a grounding grid, which is computed by means of the Hybrid Electromagnetic Model (HEM), finding the relation between voltages and input currents in two points of the grid in frequency domain. The model obtained with the MVF shows a good agreement with the frequency response of the GS. Besides, the model is tested in EMTP/ATP finding a good fitting with the calculated data, which demonstrates the validity and usefulness of the MVF. (author)

  5. Geospatial Analysis of Photovoltaic Mini-Grid System Performance

    Directory of Open Access Journals (Sweden)

    Thomas Huld

    2017-02-01

    Full Text Available We present a geographic information system (GIS-based tool for estimating the performance of photovoltaic (PV mini-grid system over large geographical areas. The methodology consists of geospatial analysis and mapping of the energy output and reliability of PV mini-grid system. The algorithm uses a combination of hourly solar radiation data from satellites combined with measured data on PV module and battery performance and estimated electricity consumption data. The methods also make it possible to optimize the PV array and battery storage size for a given location. Results are presented for an area covering Africa and most of Southern and Central Asia. We also investigate the effects of using Li-ion batteries instead of the traditional lead-acid batteries. The use of our spatial analysis as decision support tool could help governments, local authorities and non-governmental organizations to investigate the suitability of PV mini-grids for electrification of regions where access to electricity is lacking. In this way it is possible to identify areas where PV mini-grids are most suitable.

  6. Intelligent grid management with variable grid fees as indirect control system for Distribution System Operators; Intelligentes Netzlastmanagement mit variablen Netzentgelten als indirektes Steuerungsinstrument fuer Verteilnetzbetreiber

    Energy Technology Data Exchange (ETDEWEB)

    Engel, Stephan; Nestle, David; Selzam, Patrick; Strauss, Philipp [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik, Kassel (Germany)

    2011-07-01

    Variable grid fees are an incentive system to motivate the grid customers to adjust their energy consumption to the requirements of the distribution grid. Therefore, the Distribution System Operator can reduce grid peak load, improve the integration of fluctuating renewable power producers and optimize the grid load prediction. Compared to variable grid fees which are just in the research stage, peak power demand prices are an existing incentive system. The comparison between these two incentive systems demonstrates which system can support more efficiently the requirements of a sustainable energy system. In E-Energy-Project ''Modellstadt Mannheim'', a proposal for a transparent calculation of variable grid fees will be developed and a technical solution deployed. (orig.)

  7. GRID2D/3D: A computer program for generating grid systems in complex-shaped two- and three-dimensional spatial domains. Part 1: Theory and method

    Science.gov (United States)

    Shih, T. I.-P.; Bailey, R. T.; Nguyen, H. L.; Roelke, R. J.

    1990-01-01

    An efficient computer program, called GRID2D/3D was developed to generate single and composite grid systems within geometrically complex two- and three-dimensional (2- and 3-D) spatial domains that can deform with time. GRID2D/3D generates single grid systems by using algebraic grid generation methods based on transfinite interpolation in which the distribution of grid points within the spatial domain is controlled by stretching functions. All single grid systems generated by GRID2D/3D can have grid lines that are continuous and differentiable everywhere up to the second-order. Also, grid lines can intersect boundaries of the spatial domain orthogonally. GRID2D/3D generates composite grid systems by patching together two or more single grid systems. The patching can be discontinuous or continuous. For continuous composite grid systems, the grid lines are continuous and differentiable everywhere up to the second-order except at interfaces where different single grid systems meet. At interfaces where different single grid systems meet, the grid lines are only differentiable up to the first-order. For 2-D spatial domains, the boundary curves are described by using either cubic or tension spline interpolation. For 3-D spatial domains, the boundary surfaces are described by using either linear Coon's interpolation, bi-hyperbolic spline interpolation, or a new technique referred to as 3-D bi-directional Hermite interpolation. Since grid systems generated by algebraic methods can have grid lines that overlap one another, GRID2D/3D contains a graphics package for evaluating the grid systems generated. With the graphics package, the user can generate grid systems in an interactive manner with the grid generation part of GRID2D/3D. GRID2D/3D is written in FORTRAN 77 and can be run on any IBM PC, XT, or AT compatible computer. In order to use GRID2D/3D on workstations or mainframe computers, some minor modifications must be made in the graphics part of the program; no

  8. Intelligent Control for a DC Micro-Grid System

    DEFF Research Database (Denmark)

    Martino, Michele; Quiñones, Yamshid Farhat; Raboni, Pietro

    2012-01-01

    This paper presents the dynamic response of a DC–micro-grid (DC-MG) controlled in master-slave mode. The benefits of the micro-grids (MGs) are the low cost in terms of power electronics converters and the high reliability and quality, even in case of loss connection to the transmission system. A DC......-MG in fact can survive in standalone mode if properly managed. The considered system is made by a photovoltaic array (PV), a wind turbine (WT), a gas engine (GE) and an energy storage system (ESS). The DC-MG behavior is analyzed in different scenarios to demonstrate the efficacy of the control for all...... the units, especially in case of variable weather conditions with different DC loads. Thus the voltage level of the system and the power flow are shown, out of a detailed description of the power electronic interfaces featuring the distributed generators (DGs)....

  9. Sizing aspects of a small scale grid connected PV system

    Energy Technology Data Exchange (ETDEWEB)

    Bartha, S.; Teodoreanu, D.I.; Teodoreanu, M.; Negreanu, C. [I.C.P.E.-New Energy Sources Laboratory (NESL), Bucharest (Romania); Farkas, I.; Seres, I. [Szent Istvan University, Goedoelloe (Hungary). Department of Physics and Process Control

    2008-07-01

    Photovoltaics can be used in grid connected mode in two ways: as array installed at the end use site, such as on rooftops, or as utility-scale generating stations. The present paper describes a small-scale grid connected Photovoltaic system. The paper starts with the structure and characterization of the system. The principal technical parameter data are also presented. The used monitoring parameters indicate the principal meteorological data, air temperature and solar radiation data for the location sited at Agigea, at the Black Sea and the produced energy by the PV modules. The present application is made by 1 subsystem with 1200 Wp power and with the panel inclination possibility, using different type of PV modules. The paper presents a simulation model for this system realized with commercial software packages and with a one self made Matlab model that evaluates the energy balance of the PV system. All the simulation and measurements data are presented. (orig.)

  10. Online grid impedance estimation for single-phase grid-connected systems using PQ variations

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Rodriguez, Pedro;

    2007-01-01

    algorithms are used in order to estimate the value of the grid impedance. The online grid impedance estimation method can be used for compliance with the anti-islanding standard requirements (IEEE1574, IEEE929 and VDE0126) and for adaptive control of the grid-connected converters. The proposed method...

  11. Space/ground systems as cooperating agents

    Science.gov (United States)

    Grant, T. J.

    1994-01-01

    Within NASA and the European Space Agency (ESA) it is agreed that autonomy is an important goal for the design of future spacecraft and that this requires on-board artificial intelligence. NASA emphasizes deep space and planetary rover missions, while ESA considers on-board autonomy as an enabling technology for missions that must cope with imperfect communications. ESA's attention is on the space/ground system. A major issue is the optimal distribution of intelligent functions within the space/ground system. This paper describes the multi-agent architecture for space/ground systems (MAASGS) which would enable this issue to be investigated. A MAASGS agent may model a complete spacecraft, a spacecraft subsystem or payload, a ground segment, a spacecraft control system, a human operator, or an environment. The MAASGS architecture has evolved through a series of prototypes. The paper recommends that the MAASGS architecture should be implemented in the operational Dutch Utilization Center.

  12. Open System of Agile Ground Stations Project

    Data.gov (United States)

    National Aeronautics and Space Administration — There is an opportunity to build the HETE-2/TESS network of ground stations into an innovative and powerful Open System of Agile Stations, by developing a low-cost...

  13. VENTILATION SYSTEM WITH GROUND HEAT EXCHANGER

    Directory of Open Access Journals (Sweden)

    Vyacheslav Pisarev

    2016-11-01

    Full Text Available Ventilation systems consume more and more energy because of the often complex treatment of the air supplied to closed spaces. Looking for sources of energy allow for significant savings costs, which often translate into renewable energy sources. One of the more popular solutions is to use energy from the ground by various methods. Known and relatively common solutions are based on ground heat exchanger and ground collector cooperating with a heat pump. The paper presents the possibility of cooperation ventilation system with ground air heat exchanger and heat pump both in summer and winter period. A number solutions of this type of system, supported by calculation examples and moist air transformation in the Moliere chart have been presented. Support ventilation system with renewable energy sources allows significant savings in operating as shown in the article.

  14. Energy Storage Management in Grid Connected Solar Photovoltaic System

    Directory of Open Access Journals (Sweden)

    Vidhya M.E

    2015-04-01

    Full Text Available The penetration of renewable sources in the power system network in the power system has been increasing in the recent years. One of the solutions being proposed to improve the reliability and performance of these systems is to integrate energy storage device into the power system network. This paper discusses the modeling of photo voltaic and status of the storage device such as lead acid battery for better energy management in the system. The energy management for the grid connected system was performed by the dynamic switching process.

  15. Grid Monitoring and Advanced Control of Distributed Power Generation Systems

    OpenAIRE

    Timbus, Adrian Vasile

    2007-01-01

    The movement towards a clean technology for energy production and the constraints in reducing the CO2 emissions are some factors facilitating the growth of distributed power generation systems based on renewable energy resources. Consequently, large penetration of distributed generators has been reported in some countries creating concerns about power system stability. This leads to a continuous evolution of grid interconnection requirements towards a better controllability of generated power...

  16. JavaFIRE: A Replica and File System for Grids

    Science.gov (United States)

    Petek, Marko; da Silva Gomes, Diego; Resin Geyer, Claudio Fernando; Santoro, Alberto; Gowdy, Stephen

    2012-12-01

    The work is focused on the creation of a replica and file transfers system for Computational Grids inspired on the needs of the High Energy Physics (HEP). Due to the high volume of data created by the HEP experiments, an efficient file and dataset replica system may play an important role on the computing model. Data replica systems allow the creation of copies, distributed between the different storage elements on the Grid. In the HEP context, the data files are basically immutable. This eases the task of the replica system, because given sufficient local storage resources any dataset just needs to be replicated to a particular site once. Concurrent with the advent of computational Grids, another important theme in the distributed systems area that has also seen some significant interest is that of peer-to-peer networks (p2p). P2p networks are an important and evolving mechanism that eases the use of distributed computing and storage resources by end users. One common technique to achieve faster file download from possibly overloaded storage elements over congested networks is to split the files into smaller pieces. This way, each piece can be transferred from a different replica, in parallel or not, optimizing the moments when the network conditions are better suited to the transfer. The main tasks achieved by the system are: the creation of replicas, the development of a system for replicas transfer (RFT) and for replicas location (RLS) with a different architecture that the one provided by Globus and the development of a system for file transfer in pieces on computational grids with interfaces for several storage elements. The RLS uses a p2p overlay based on the Kademlia algorithm.

  17. Distribution System Reliability Analysis for Smart Grid Applications

    Science.gov (United States)

    Aljohani, Tawfiq Masad

    Reliability of power systems is a key aspect in modern power system planning, design, and operation. The ascendance of the smart grid concept has provided high hopes of developing an intelligent network that is capable of being a self-healing grid, offering the ability to overcome the interruption problems that face the utility and cost it tens of millions in repair and loss. To address its reliability concerns, the power utilities and interested parties have spent extensive amount of time and effort to analyze and study the reliability of the generation and transmission sectors of the power grid. Only recently has attention shifted to be focused on improving the reliability of the distribution network, the connection joint between the power providers and the consumers where most of the electricity problems occur. In this work, we will examine the effect of the smart grid applications in improving the reliability of the power distribution networks. The test system used in conducting this thesis is the IEEE 34 node test feeder, released in 2003 by the Distribution System Analysis Subcommittee of the IEEE Power Engineering Society. The objective is to analyze the feeder for the optimal placement of the automatic switching devices and quantify their proper installation based on the performance of the distribution system. The measures will be the changes in the reliability system indices including SAIDI, SAIFI, and EUE. The goal is to design and simulate the effect of the installation of the Distributed Generators (DGs) on the utility's distribution system and measure the potential improvement of its reliability. The software used in this work is DISREL, which is intelligent power distribution software that is developed by General Reliability Co.

  18. Modeling Supermarket Refrigeration Systems for Supervisory Control in Smart Grid

    DEFF Research Database (Denmark)

    Shafiei, Seyed Ehsan; Rasmussen, Henrik; Stoustrup, Jakob

    2013-01-01

    A modular modeling approach of supermarket refrigeration systems (SRS) which is appropriate for smart grid control purposes is presented in this paper. Modeling and identification are performed by just knowing the system configuration and measured data disregarding the physical details. So......, this approach is extendable to different configurations with different modules. The focus of the work is on estimating the power consumption of the system while estimating the display case temperatures as well. This model can however be employed as a simulation benchmark to develop control methods for SRS...... regarding their power/energy consumptions in the future smart grids. Moreover, the developed model is validated by real data collected from a supermarket in Denmark. The utilization of the produced model is also illustrated by a simple simulation example....

  19. Fuel Cost Estimation for Sumatra Grid System

    Science.gov (United States)

    Liun, Edwaren

    2010-06-01

    Sumatra has a high growth rate electricity energy demand from the first decade in this century. At the medium of this decade the growth is 11% per annum. On the other side capability of Government of Indonesia cq. PLN authority is limited, while many and most old existing power plants will be retired. The electricity demand growth of Sumatra is increasing the fuel consumption for several next decades. Based on several cases by vary growth scenarios and economic parameters, it shown that some kinds of fossil fuel keep to be required until next several decades. Although Sumatra has abundant coal resource, however, the other fuel types such as fuel oil, diesel, gas and nuclear are needed. On the Base Scenario and discount rate of 10%, the Sumatra System will require 11.6 million tones of coal until 2030 producing 866 TWh with cost of US10558 million. Nuclear plants produce about 501 TWh or 32% by cost of US3.1 billion. On the High Scenario and discount rate 10%, the coal consumption becomes 486.6 million tones by fuel cost of US12.7 billion producing 1033 TWh electricity energy. Nuclear fuel cost required in this scenario is US7.06 billion. The other fuel in large amount consumed is natural gas for combined cycle plants by cost of US1.38 billion producing 11.7 TWh of electricity energy on the Base Scenario and discount rate of 10%. In the High Scenario and discount rate 10% coal plants take role in power generation in Sumatra producing about 866 TWh or 54% of electricity energy. Coal consumption will be the highest on the Base Scenario with discount rate of 12% producing 756 TWh and required cost of US17.1 billion. Nuclear plants will not applicable in this scenario due to its un-competitiveness. The fuel cost will depend on nuclear power role in Sumatra system. Fuel cost will increase correspond to the increasing of coal consumption on the case where nuclear power plants not appear.

  20. Does Your Domestic Photovoltaic Energy System Survive Grid Outages?

    Directory of Open Access Journals (Sweden)

    Marijn R. Jongerden

    2016-09-01

    Full Text Available Domestic renewable energy systems, including photovoltaic energy generation, as well as local storage, are becoming increasingly popular and economically feasible, but do come with a wide range of options. Hence, it can be difficult to match their specification to specific customer’s needs. Next to the usage-specific demand profiles and location-specific production profiles, local energy storage through the use of batteries is becoming increasingly important, since it allows one to balance variations in production and demand, either locally or via the grid. Moreover, local storage can also help to ensure a continuous energy supply in the presence of grid outages, at least for a while. Hybrid Petri net (HPN models allow one to analyze the effect of different battery management strategies on the continuity of such energy systems in the case of grid outages. The current paper focuses on one of these strategies, the so-called smart strategy, that reserves a certain percentage of the battery capacity to be only used in case of grid outages. Additionally, we introduce a new strategy that makes better use of the reserved backup capacity, by reducing the demand in the presence of a grid outage through a prioritization mechanism. This new strategy, called power-save, only allows the essential (high-priority demand to draw from the battery during power outages. We show that this new strategy outperforms previously-proposed strategies through a careful analysis of a number of scenarios and for a selection of survivability measures, such as minimum survivability per day, number of survivable hours per day, minimum survivability per year and various survivability quantiles.

  1. Detection and Protection Against Intrusions on Smart Grid Systems

    Directory of Open Access Journals (Sweden)

    Ata Arvani

    2015-05-01

    Full Text Available The wide area monitoring of power systems is implemented at a central control center to coordinate the actions of local controllers. Phasor measurement units (PMUs are used for the collection of data in real time for the smart grid energy systems. Intrusion detection and cyber security of network are important requirements for maintaining the integrity of wide area monitoring systems. The intrusion detection methods analyze the measurement data to detect any possible cyber attacks on the operation of smart grid systems. In this paper, the model-based and signal-based intrusion detection methods are investigated to detect the presence of malicious data. The chi-square test and discrete wavelet transform (DWT have been used for anomaly-based detection. The false data injection attack (FDIA can be detected using measurement residual. If the measurement residual is larger than expected detection threshold, then an alarm is triggered and bad data can be identified. Avoiding such alarms in the residual test is referred to as stealth attack. There are two protection strategies for stealth attack: (1 Select a subset of meters to be protected from the attacker (2 Place secure phasor measurement units in the power grid. An IEEE 14-bus system is simulated using real time digital simulator (RTDS hardware platform for implementing attack and detection schemes.

  2. H-Bridge Transformerless Inverter with Common Ground for Single-Phase Solar-Photovoltaic System

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede

    2017-01-01

    This paper proposes a new single-phase H-Bridge transformerless inverter with common ground for grid-connected photovoltaic systems (hereafter it is called ‘Siwakoti-H’ inverter). The inverter works on the principle of flying capacitor and consists of only four power switches (two reverse blockin...

  3. Global distribution of grid connected electrical energy storage systems

    Directory of Open Access Journals (Sweden)

    Katja Buss

    2016-06-01

    Full Text Available This article gives an overview of grid connected electrical energy storage systems worldwide, based on public available data. Technologies considered in this study are pumped hydroelectric energy storage (PHES, compressed air energy storage (CAES, sodium-sulfur batteries (NaS, lead-acid batteries, redox-flow batteries, nickel-cadmium batteries (NiCd and lithium-ion batteries. As the research indicates, the worldwide installed capacity of grid connected electrical energy storage systems is approximately 154 GW. This corresponds to a share of 5.5 % of the worldwide installed generation capacity. Furthermore, the article gives an overview of the historical development of installed and used storage systems worldwide. Subsequently, the focus is on each considered technology concerning the current storage size, number of plants and location. In summary it can be stated, PHES is the most commonly used technology worldwide, whereas electrochemical technologies are increasingly gaining in importance. Regarding the distribution of grid connected storage systems reveals the share of installed storage capacity is in Europe and Eastern Asia twice as high as in North America.

  4. A composite controller for grid connected photovoltaic systems

    Institute of Scientific and Technical Information of China (English)

    Dong Mi; Yang Jian; Luo An

    2008-01-01

    This paper addresses a new composite controller for a boost-buck inverter to interface the photovoltaic array with the power grid. Based on dynamically tracking the maximum power point, two novel control methodologies are proposed to control the DC-bus and the output current for the inverter. First, a new linear cycle discrete control algorithm is introduced to realize linear control of the DC-bus voltage and synchronously get the reference current for the inner current loop with a little calculation. Then, to assure a good adaptability to noise and model uncertainty, an auto-disturbance rejection controller is chosen as the output current controller, which does not depend on precise mathematics model. Thus, output current of PV system to the grid is with low harmonic distortion and unity power factor. Simulations and experiments are performed, and the results show that the system is of excellent robustness and effective.

  5. DDGrid: a grid computing system for drug discovery and design

    Institute of Scientific and Technical Information of China (English)

    Chen Shudong; Zhang Liang; Ma Fanyuan; Shen Jianhua

    2005-01-01

    This paper presents DDGrid, a novel Grid computing system for drug discovery and design. By utilizing the idle resources donated by the clusters that scatter over the Internet, DDGrid can implement efficient data-intensive biologic applications. The high-level resource management framework with a Grid-P2P hybrid architecture is described. With P2P technologies, some problems which are inevitable in the master-slave model can be avoided, such as single point of failure or performance bottleneck. Then an agent-based resource scheduling algorithm is presented. With this scheduling algorithm, the idle computational resources are dynamically scheduled according to the real-time working load on each execution node. Thus DDGrid can hold an excellent load balance state. Furthermore, the framework is introduced into the practical protein molecules docking applications. Solid experimental results show the load balance and robustness of the proposed system, which can greatly speed up the process of protein molecules docking.

  6. A Technique for Shunt Active Filter meld micro grid System

    Directory of Open Access Journals (Sweden)

    A. Lumani

    2015-08-01

    Full Text Available The proposed system presents a control technique for a micro grid connected hybrid generation system ith case study interfaced with a three phase shunt active filter to suppress the current harmonics and reactive power present in the load using PQ Theory with ANN controller. This Hybrid Micro Grid is developed using freely renewable energy resources like Solar Photovoltaic (SPV and Wind Energy (WE. To extract the maximum available power from PV panels and wind turbines, Maximum power point Tracker (MPPT has been included. This MPPT uses the “Standard Perturbs and Observe” technique. By using PQ Theory with ANN Controller, the Reference currents are generated which are to be injected by Shunt active power filter (SAPFto compensate the current harmonics in the non linear load. Simulation studies shows that the proposed control technique performs non-linear load current harmonic compensation maintaining the load current in phase with the source voltage.\\

  7. Rethinking the Future Grid: Integrated Nuclear Renewable Energy Systems: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Bragg-Sitton, S. M.; Boardman, R.; Ruth, M.; Zinaman, O.; Forsberg, C.

    2015-01-01

    The U.S. DOE is supporting research and development that could lead to more efficient utilization of clean energy generation sources, including renewable and nuclear options, to meet both grid demand and thermal energy needs in the industrial sector. One concept under consideration by the DOE-NE and DOE-EERE is tighter coupling of nuclear and renewable energy sources in a manner that better optimizes energy use for the combined electricity, industrial manufacturing, and transportation sectors. This integration concept has been referred to as a 'hybrid system' that is capable of apportioning thermal and electrical energy to first meet the grid demand (with appropriate power conversion systems), then utilizing excess thermal and, in some cases, electrical energy to drive a process that results in an additional product.

  8. A monitoring sensor management system for grid environments

    Energy Technology Data Exchange (ETDEWEB)

    Tierney, Brian; Crowley, Brian; Gunter, Dan; Lee, Jason; Thompson, Mary

    2001-06-01

    Large distributed systems, such as computational grids,require a large amount of monitoring data be collected for a variety oftasks, such as fault detection, performance analysis, performance tuning,performance prediction and scheduling. Ensuring that all necessarymonitoring is turned on and that the data is being collected can be avery tedious and error-prone task. We have developed an agent-basedsystem to automate the execution of monitoring sensors and the collectionof event data.

  9. A monitoring sensor management system for grid environments

    Energy Technology Data Exchange (ETDEWEB)

    Tierney, Brian; Crowley, Brian; Gunter, Dan; Lee, Jason; Thompson, Mary

    2001-06-01

    Large distributed systems, such as computational grids,require a large amount of monitoring data be collected for a variety oftasks, such as fault detection, performance analysis, performance tuning,performance prediction and scheduling. Ensuring that all necessarymonitoring is turned on and that the data is being collected can be avery tedious and error-prone task. We have developed an agent-basedsystem to automate the execution of monitoring sensors and the collectionof event data.

  10. Transient Control of Synchronous Machine Active and Reactive Power in Micro-grid Power Systems

    Science.gov (United States)

    Weber, Luke G.

    power. The scope of this work is to • develop a mathematical model for a salient pole, 2 damper winding synchronous generator with d axis saturation suitable for transient analysis, • develop a mathematical model for a voltage regulator and excitation system using the IEEE AC8B voltage regulator and excitation system template, • develop mathematical models for an energy storage primary control system, LC filter and transformer suitable for transient analysis, • combine the generator and energy storage models in a micro-grid context, • develop mathematical models for electric system components in the stationary abc frame and rotating dq reference frame, • develop a secondary control network for dispatch of micro-grid assets, • establish micro-grid limits of stable operation for step changes in load and power commands based on simulations of model data assuming net load on the micro-grid, and • use generator and electric system models to assess the generator current magnitude during phase-to-ground faults.

  11. Smart EV Energy Management System to Support Grid Services

    Science.gov (United States)

    Wang, Bin

    Under smart grid scenarios, the advanced sensing and metering technologies have been applied to the legacy power grid to improve the system observability and the real-time situational awareness. Meanwhile, there is increasing amount of distributed energy resources (DERs), such as renewable generations, electric vehicles (EVs) and battery energy storage system (BESS), etc., being integrated into the power system. However, the integration of EVs, which can be modeled as controllable mobile energy devices, brings both challenges and opportunities to the grid planning and energy management, due to the intermittency of renewable generation, uncertainties of EV driver behaviors, etc. This dissertation aims to solve the real-time EV energy management problem in order to improve the overall grid efficiency, reliability and economics, using online and predictive optimization strategies. Most of the previous research on EV energy management strategies and algorithms are based on simplified models with unrealistic assumptions that the EV charging behaviors are perfectly known or following known distributions, such as the arriving time, leaving time and energy consumption values, etc. These approaches fail to obtain the optimal solutions in real-time because of the system uncertainties. Moreover, there is lack of data-driven strategy that performs online and predictive scheduling for EV charging behaviors under microgrid scenarios. Therefore, we develop an online predictive EV scheduling framework, considering uncertainties of renewable generation, building load and EV driver behaviors, etc., based on real-world data. A kernel-based estimator is developed to predict the charging session parameters in real-time with improved estimation accuracy. The efficacy of various optimization strategies that are supported by this framework, including valley-filling, cost reduction, event-based control, etc., has been demonstrated. In addition, the existing simulation-based approaches do

  12. Doubly Fed Induction Generator Wind Turbine Systems Subject to Recurring Symmetrical Grid Faults

    DEFF Research Database (Denmark)

    Chen, Wenjie; Blaabjerg, Frede; Zhu, Nan

    2016-01-01

    grid faults is established. The analysis is based on the DFIG wind turbine system with the typical low-voltage ride-through strategy-with rotor-side crowbar. The stator natural flux produced by the voltage recovery after the first grid fault may be superposed on the stator natural flux produced......New grid codes demand the wind turbine systems to ride through recurring grid faults. In this paper, the performance of the doubly Ffed induction generator (DFIG) wind turbine system under recurring symmetrical grid faults is analyzed. The mathematical model of the DFIG under recurring symmetrical...... by the second grid fault, so that the transient rotor and stator current and torque fluctuations under the second grid fault may be influenced by the characteristic of the first grid fault, including the voltage dips level and the grid fault angle, as well as the duration between two faults. The mathematical...

  13. Optimization of Renewable Energy Hybrid System for Grid Connected Application

    Directory of Open Access Journals (Sweden)

    Mustaqimah Mustaqimah

    2012-10-01

    Full Text Available ABSTRACT. Hybrid energy systems are pollution free, takes low cost and less gestation period, user and social friendly. Such systems are important sources of energy for shops, schools, and clinics in village communities especially in remote areas. Hybrid systems can provide electricity at a comparatively economic price in many remote areas. This paper presents a method to jointly determine the sizing and operation control of hybrid energy systems. The model, PV wind hydro and biomass hybrid system connects to grid. The system configuration of the hybrid is derived based on a theoretical domestic load at a typical location and local solar radiation, wind and water flow rate data and biomass availability. The hybrid energy system is proposed for 10 of teacher’s houses of Industrial Training Institute, Mersing. It is predicted 10 kW load consumption per house. The hybrid energy system consists of wind, solar, biomass, hydro, and grid power. Approximately energy consumption is 860 kWh/day with a 105 kW peak demand load. The proposed hybrid renewable consists of solar photovoltaic (PV panels, wind turbine, hydro turbine and biomass. Battery and inverter are included as part of back-up and storage system. It provides the economic sensitivity of hybridization and the economic and environmental benefits of using a blend of technologies. It also presents the trade off that is involved in optimizing a hybrid energy system to harness and utilize the available renewable energy resources efficiently.

  14. Equivalent Simplification Method of Micro-Grid

    OpenAIRE

    Cai Changchun; Cao Xiangqin

    2013-01-01

    The paper concentrates on the equivalent simplification method for the micro-grid system connection into distributed network. The equivalent simplification method proposed for interaction study between micro-grid and distributed network. Micro-grid network, composite load, gas turbine synchronous generation, wind generation are equivalent simplification and parallel connect into the point of common coupling. A micro-grid system is built and three phase and single phase grounded faults are per...

  15. Ground states of linearly coupled Schrodinger systems

    Directory of Open Access Journals (Sweden)

    Haidong Liu

    2017-01-01

    Full Text Available This article concerns the standing waves of a linearly coupled Schrodinger system which arises from nonlinear optics and condensed matter physics. The coefficients of the system are spatially dependent and have a mixed behavior: they are periodic in some directions and tend to positive constants in other directions. Under suitable assumptions, we prove that the system has a positive ground state. In addition, when the L-infinity-norm of the coupling coefficient tends to zero, the asymptotic behavior of the ground states is also obtained.

  16. Wind energy management for smart grids with storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Gasco, Manuel [Universidad de Alicante (Spain). Area de Ingenieria Electrica; Rios, Alberto [Universidad Europea de Madrid (Spain). Area de Ingenieria Electrica

    2012-07-01

    Increasing integration of wind energy into the power system makes the optimal management of different situations that can occur more and more important. The objective of the present study is to replace the power necessary for electrical feed when the wind resources are not available, and to make a continuous demand tracking of the power. The energy storage systems treated in this study are as follows: a fuel cell, flywheel, pump systems and turbine systems, compressed air systems, electrochemical cells, electric vehicles, supercapacitors and superconductors. As a result the maximum benefit of the smart grid is achieved and it includes coexistence of the energy storage systems described and integrated in the numerous microgrids which can form the distribution grid. The current capacity is observed in order to be able to manage the wind generation for short periods of time. This way it is possible to plan the production which would be adjusted to the variations through these storage systems allowing the systems to maintain their constant programming for the base plants, adjusting the variations in these systems in the short term. (orig.)

  17. 40 CFR 265.91 - Ground-water monitoring system.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Ground-water monitoring system. 265.91... DISPOSAL FACILITIES Ground-Water Monitoring § 265.91 Ground-water monitoring system. (a) A ground-water monitoring system must be capable of yielding ground-water samples for analysis and must consist of: (1...

  18. Applying Modeling Tools to Ground System Procedures

    Science.gov (United States)

    Di Pasquale, Peter

    2012-01-01

    As part of a long-term effort to revitalize the Ground Systems (GS) Engineering Section practices, Systems Modeling Language (SysML) and Business Process Model and Notation (BPMN) have been used to model existing GS products and the procedures GS engineers use to produce them.

  19. Static Equivalent of Distribution Grids With High Penetration of PV Systems

    DEFF Research Database (Denmark)

    Samadi, Afshin; Söder, Lennart; Shayesteh, Ebrahim;

    2015-01-01

    High penetrations of photovoltaic (PV) systems within load pockets in distribution grids have changed pure consumers to prosumers. This can cause technical challenges in distribution and transmission grids, such as overvoltage and reverse power flow. Embedding voltage support schemes into PVs......, such as standard cos phi(P) characteristic proposed by the German grid codes, may cause more changes in the steady-state behavior of distribution grids and, in turn, the transmission side. Accordingly, it is important to properly model active distribution grids to analyze the system impacts of these changes...... to plan and operate future smart power grids. However, due to the high dimension of distribution grids, considering a detailed distribution grid to study the transmission side or a fraction of the distribution grid is either cumbersome or impractical. Therefore, it is required to develop a reasonable...

  20. Solar power management for smart grids with storage systems

    Energy Technology Data Exchange (ETDEWEB)

    Gasco, Manuel [Universidad de Alicante (Spain). Area de Ingenieria Electrica; Rios, Alberto [Universidad Europea de Madrid (Spain). Area de Ingenieria Electrica

    2012-07-01

    The increasing integration of solar photovoltaic power into the power system makes the optimal management of different situations that can occur more and more important. The current capacity is observed in order to be able to predict the solar generation for short periods of time. This way it is possible to plan the production which would be adjusted to the variations in these storage systems allowing the system to maintain its constant programming for base plants, adjusting the variations in these systems in the short term. The referred accumulation systems are as follows: a fuel cell, mass flywheel, pump and turbine systems, compressed air systems, electrochemical cells, supercapacitors, superconductors, and electric vehicles. As a result the maximum benefit for the smart grid is achieved. (orig.)

  1. Time Stamp Attack on Wide Area Monitoring System in Smart Grid

    CERN Document Server

    Zhang, Zhenghao; Li, Husheng; Pei, Changxing

    2011-01-01

    Security becomes an extremely important issue in smart grid. To maintain the steady operation for smart power grid, massive measurement devices must be allocated widely among the power grid. Previous studies are focused on false data injection attack to the smart grid system. In practice, false data injection attack is not easy to implement, since it is not easy to hack the power grid data communication system. In this paper, we demonstrate that a novel time stamp attack is a practical and dangerous attack scheme for smart grid. Since most of measurement devices are equipped with global positioning system (GPS) to provide the time information of measurements, it is highly probable to attack the measurement system by spoofing the GPS. By employing the real measurement data in North American Power Grid, simulation results demonstrate the effectiveness of the time stamp attack on smart grid.

  2. A Component Mining Approach to Incubate Grid Services in Object-Oriented Legacy Systems

    Institute of Scientific and Technical Information of China (English)

    Jian-Zhi Li; Zhuo-Peng Zhang; Bing Qiao; Hong-Ji Yang

    2006-01-01

    This paper describes an approach for Grid service component mining in object-oriented legacy systems, applying software clustering, architecture recovery, program slicing and wrapping techniques to decompose a legacy system, analyse the concerned components and integrate them into a Grid environment. The resulting components with core legacy code function in a Grid service framework.

  3. Efficient Bulk Data Replication for the Earth System Grid

    Energy Technology Data Exchange (ETDEWEB)

    Sim, Alex [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gunter, Dan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Natarajan, Vijaya [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shoshani, Arie [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Williams, Dean [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Long, Jeff [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Hick, Jason [National Energy Research Scientific Computing Center, Berkeley, CA (United States); Lee, Jason [National Energy Research Scientific Computing Center, Berkeley, CA (United States); Dart, Eli [Energy Sciences Network, Berkeley, CA (United States)

    2010-03-10

    The Earth System Grid (ESG) community faces the difficult challenge of managing the distribution of massive data sets to thousands of scientists around the world. To move data replicas efficiently, the ESG has developed a data transfer management tool called the Bulk Data Mover (BDM). We describe the performance results of the current system and plans towards extending the techniques developed so far for the up- coming project, in which the ESG will employ advanced networks to move multi-TB datasets with the ulti- mate goal of helping researchers understand climate change and its potential impacts on world ecology and society.

  4. System design specification Brayton Isotope Power System (BIPS) Flight System (FS), and Ground Demonstration System (GDS)

    Energy Technology Data Exchange (ETDEWEB)

    1976-06-14

    The system design specification for ground demonstration, development, and flight qualification of a Brayton Isotope Power System (BIPS) is presented. The requirements for both a BIPS conceptual Flight System (FS) and a Ground Demonstration System (GDS) are defined.

  5. Storage Size Determination for Grid-Connected Photovoltaic Systems

    CERN Document Server

    Ru, Yu; Martinez, Sonia

    2011-01-01

    In this paper, we study the problem of determining the size of battery storage used in grid-connected photovoltaic (PV) systems. In our setting, electricity is generated from PV and is used to supply the demand from loads. Excess electricity generated from the PV can be stored in a battery to be used later on, and electricity must be purchased from the electric grid if the PV generation and battery discharging cannot meet the demand. The objective is to minimize the electricity purchase from the electric grid while at the same time choosing an appropriate battery size. More specifically, we want to find a unique critical value (denoted as $E_{max}^c$) of the battery size such that the cost of electricity purchase remains the same if the battery size is larger than or equal to $E_{max}^c$, and the cost is strictly larger if the battery size is smaller than $E_{max}^c$. We propose an upper bound on $E_{max}^c$, and show that the upper bound is achievable for certain scenarios. For the case with ideal PV generat...

  6. Optimization Design System for Composite Structures Based on Grid Technology

    Institute of Scientific and Technical Information of China (English)

    CHENG Wen-yuan; CHANG Yan; CUI De-gang; XIE Xiang-hui

    2007-01-01

    To solve the topology optimization of complicated multi-objective continuous/discrete design variables in aircraft structure design, a Parallel Pareto Genetic Algorithm (PPGA) is presented based on grid platform in this paper. In the algorithm, the commercial finite element analysis (FEA) software is integrated as the calculating tool for analyzing the objective functions and the filter of Pareto solution set based on weight information is introduced to deal with the relationships among all objectives. Grid technology is utilized in PPGA to realize the distributed computations and the user interface is developed to realize the job submission and job management locally/remotely. Taking the aero-elastic tailoring of a composite wing for optimization as an example, a set of Pareto solutions are obtained for the decision-maker. The numerical results show that the aileron reversal problem can be solved by adding the limited skin weight in this system. The algorithm can be used to solve complicated topology optimization for composite structures in engineering and the computation efficiency can be improved greatly by using the grid platform that aggregates numerous idle resources.

  7. Semantic Grounding Strategies for Tagbased Recommender Systems

    CERN Document Server

    Durao, Frederico

    2011-01-01

    Recommender systems usually operate on similarities between recommended items or users. Tag based recommender systems utilize similarities on tags. The tags are however mostly free user entered phrases. Therefore, similarities computed without their semantic groundings might lead to less relevant recommendations. In this paper, we study a semantic grounding used for tag similarity calculus. We show a comprehensive analysis of semantic grounding given by 20 ontologies from different domains. The study besides other things reveals that currently available OWL ontologies are very narrow and the percentage of the similarity expansions is rather small. WordNet scores slightly better as it is broader but not much as it does not support several semantic relationships. Furthermore, the study reveals that even with such number of expansions, the recommendations change considerably.

  8. A Taxonomy of Performance Prediction Systems in the Parallel and Distributed Computing Grids

    OpenAIRE

    2013-01-01

    As Grids are loosely-coupled congregations of geographically distributed heterogeneous resources, the efficient utilization of the resources requires the support of a sound Performance Prediction System (PPS). The performance prediction of grid resources is helpful for both Resource Management Systems and grid users to make optimized resource usage decisions. There have been many PPS projects that span over several grid resources in several dimensions. In this paper the taxonomy for describin...

  9. Distributed intelligence for ground/space systems

    Science.gov (United States)

    Aarup, Mads; Munch, Klaus Heje; Fuchs, Joachim; Hartmann, Ralf; Baud, Tim

    1994-01-01

    DI is short for Distributed Intelligence for Ground/Space Systems and the DI Study is one in a series of ESA projects concerned with the development of new concepts and architectures for future autonomous spacecraft systems. The kick-off of DI was in January 1994 and the planned duration is three years. The background of DI is the desire to design future ground/space systems with a higher degree of autonomy than seen in today's missions. The aim of introducing autonomy in spacecraft systems is to: (1) lift the role of the spacecraft operators from routine work and basic troubleshooting to supervision; (2) ease access to and increase availability of spacecraft resources; (3) carry out basic mission planning for users; (4) enable missions which have not yet been feasible due to eg. propagation delays, insufficient ground station coverage etc.; and (5) possibly reduce mission cost. The study serves to identify the feasibility of using state-of-the-art technologies in the area of planning, scheduling, fault detection using model-based diagnosis and knowledge processing to obtain a higher level of autonomy in ground/space systems.

  10. Optimising the economic viability of grid-connected photovoltaic systems

    Energy Technology Data Exchange (ETDEWEB)

    Mondol, Jayanta Deb; Yohanis, Yigzaw G [School of the Built Environment, University of Ulster, Newtownabbey, Northern Ireland BT370QB (United Kingdom); Norton, Brian [Dublin Institute of Technology, Aungier Street, Dublin 2 (Ireland)

    2009-07-15

    The impact of photovoltaic (PV) array size, orientation, inclination, load profile, electricity buying price, feed-in tariffs, PV/inverter sizing ratio ('sizing ratio') and PV/inverter cost ratio ('cost ratio') on the economic viability of a grid-connected PV system was investigated using a validated TRNSYS simulation model. The results showed that the fractional load met directly by a PV system depends on matching between PV supply and building load profile, sizing ratio and PV inclination. The profitability of a grid-connected PV system increases if the PV system is sized to reduce excess PV electrical energy fed to the grid when the feed-in tariff is lower than electricity buying price. The effect of feed-in tariffs on PV saving for selected European countries has been shown. The cost of the PV electricity depends on sizing ratio, PV and inverter lifetimes, cost ratio, PV inclination and financial parameters. The effect of cost ratio on the optimum PV/inverter sizing ratio is less significant when the cost ratio lies within 7-11. The minimum PV electricity cost at low and high insolation conditions were obtained for sizing ratios of 1.6 and 1.2, respectively. The lowest PV electricity cost was found for surface slopes within 30-40 for the selected European locations. The PV electricity cost for cost ratio of 5 and 13 varied from 0.44-0.85 EURkWh{sup -1} to 0.38-0.76 EURkWh{sup -1}, respectively within high to low insolation conditions when the PV module unit cost, market discount rate, PV size, PV lifetime and inverter lifetime were assumed to be 6.5 EURW{sub p}{sup -1}, 3%, 13 kW{sub p}, 20 years and 10 years, respectively. (author)

  11. Wire-grid electromagnetic modelling of metallic cylindrical objects with arbitrary section, for Ground Penetrating Radar applications

    Science.gov (United States)

    Adabi, Saba; Pajewski, Lara

    2014-05-01

    This work deals with the electromagnetic wire-grid modelling of metallic cylindrical objects, buried in the ground or embedded in a structure, for example in a wall or in a concrete slab. Wire-grid modelling of conducting objects was introduced by Richmond in 1966 [1] and, since then, this method has been extensively used over the years to simulate arbitrarily-shaped objects and compute radiation patterns of antennas, as well as the electromagnetic field scattered by targets. For any wire-grid model, a fundamental question is the choice of the optimum wire radius and grid spacing. The most widely used criterion to fix the wire size is the so-called same-area rule [2], coming from empirical observation: the total surface area of the wires has to be equal to the surface area of the object being modelled. However, just few authors have investigated the validity of this criterion. Ludwig [3] studied the reliability of the rule by examining the canonical radiation problem of a transverse magnetic field by a circular cylinder fed with a uniform surface current, compared with a wire-grid model; he concluded that the same-area rule is optimum and that too thin wires are just as bad as too thick ones. Paknys [4] investigated the accuracy of the same-area rule for the modelling of a circular cylinder with a uniform current on it, continuing the study initiated in [3], or illuminated by a transverse magnetic monochromatic plane wave; he deduced that the same-area rule is optimal and that the field inside the cylinder is most sensitive to the wire radius than the field outside the object, so being a good error indicator. In [5], a circular cylinder was considered, embedded in a dielectric half-space and illuminated by a transverse magnetic monochromatic plane wave; the scattered near field was calculated by using the Cylindrical-Wave Approach and numerical results, obtained for different wire-grid models in the spectral domain, were compared with the exact solution. The

  12. Improved Grid Synchronization Algorithm for DG System using and UH PLL under Grid disturbances

    Directory of Open Access Journals (Sweden)

    R.Godha

    2014-12-01

    Full Text Available Distributed Generation (DG System is a small scale electric power generation at or near the user’s facility as opposed to the normal mode of centralized power generation. In order to ensure safe and reliable operation of power system based on DS, grid synchronization algorithm plays a very important role. Unbalanced Harmonic (UH based phase locked loop (PLL aimed to provide an estimation of the angular frequency and both the positive and negative sequences of the fundamental component of an unbalanced threephase signal. The UH PLL does not require transformation of variables into synchronous reference frame coordinates. Therefore, the proposed scheme is not based on the phase angle detection. Instead the angular frequency is detected and used for synchronization purposes. The design of this PLL is based on a complete description of the source voltage involving both positive and negative sequences in stationary coordinates and considering the angular frequency as an uncertain parameter. Therefore UHPLL is intended to perform properly under severe unbalanced conditions and to be robust against angular frequency variations, sags and swells in the three-phase utility voltage signal.

  13. Features of the Deployed NPOESS Ground System

    Science.gov (United States)

    Smith, D.; Grant, K. D.; Route, G.; Heckmann, G.

    2009-12-01

    NOAA, DoD, and NASA are jointly acquiring the National Polar-orbiting Operational Environmental Satellite System (NPOESS) replacing the current NOAA Polar-orbiting Operational Environmental Satellites (POES) and the DoD's Defense Meteorological Satellite Program (DMSP). The NPOESS satellites will carry a suite of sensors to collect meteorological, oceanographic, climatological, and solar-geophysical observations of the earth, atmosphere and space. The ground data processing segment is the Interface Data Processing Segment (IDPS), developed by Raytheon Intelligence & Information Systems (IIS). The IDPS processes NPOESS satellite data to provide environmental data products (aka, Environmental Data Records or EDRs) to US NOAA and DoD processing centers. The IDPS will process EDRs beginning with the NPOESS Preparatory Project (NPP) and through the lifetime of the NPOESS system. The command and telemetry segment is the Command, Control and Communications Segment (C3S), also developed by Raytheon IIS. C3S is responsible for managing the overall NPOESS mission from control and status of the space and ground assets to ensuring delivery of timely, high quality data from the Space Segment (SS) to IDPS for processing. In addition, the C3S provides the globally distributed ground assets necessary to collect and transport mission, telemetry, and command data between the satellites and the processing locations. The C3S provides all functions required for day-to-day commanding and state-of-health monitoring of the NPP and NPOESS satellites, and delivery of SMD to each Central IDP for data products development and transfer to System subscribers. The C3S also monitors and reports system-wide health, status and data communications with external systems and between the NPOESS segments. The NPOESS C3S and IDPS ground segments have been delivered and transitioned to operations for NPP. C3S was transitioned to operations at the NOAA Satellite Operations Facility in Suitland MD in August

  14. RETHINKING THE FUTURE GRID: INTEGRATED NUCLEAR-RENEWABLE ENERGY SYSTEMS

    Energy Technology Data Exchange (ETDEWEB)

    S.M. Bragg-Sitton; R. Boardman

    2014-12-01

    The 2013 electricity generation mix in the United States consisted of ~13% renewables (hydropower, wind, solar, geothermal), 19% nuclear, 27% natural gas, and 39% coal. In the 2011 State of the Union Address, President Obama set a clean energy goal for the nation: “By 2035, 80 percent of America’s electricity will come from clean energy sources. Some folks want wind and solar. Others want nuclear, clean coal and natural gas. To meet this goal we will need them all.” The U.S. Department of Energy (DOE) Offices of Nuclear Energy (NE) and Energy Efficiency and Renewable Energy (EERE) recognize that “all of the above” means that we are called to best utilize all available clean energy sources. To meet the stated environmental goals for electricity generation and for the broader energy sector, there is a need to transform the energy infrastructure of the U.S. and elsewhere. New energy systems must be capable of significantly reducing environmental impacts in an efficient and economically viable manner while utilizing both hydrocarbon resources and clean energy generation sources. The U.S. DOE is supporting research and development that could lead to more efficient utilization of clean energy generation sources, including renewable and nuclear options, to meet both grid demand and thermal energy needs in the industrial sector. A concept being advanced by the DOE-NE and DOE-EERE is tighter coupling of nuclear and renewable energy sources in a manner that better optimizes energy use for the combined electricity, industrial manufacturing, and the transportation sectors. This integration concept has been referred to as a “hybrid system” that is capable of apportioning thermal and electrical energy to first meet the grid demand (with appropriate power conversion systems), then utilizing excess thermal and, in some cases, electrical energy to drive a process that results in an additional product. For the purposes of the present work, the hybrid system would

  15. Development of standardised control and connection systems for mini grid applications

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, D.

    2002-07-01

    Dulas Ltd undertook a project to develop the application of standard grid connection equipment for use by small-scale hydroelectric systems in a mini-grid (or isolated grid) environment. The mini-grid system has greatest potential in developing countries where there is no well-established distribution system. The study was conducted on two small hydro generators which could be connected to form a mini grid with the addition of some generator control and protection equipment and a controllable load system. It was demonstrated that standard control units can be used to connect hydro generators to a mini-grid and maintain the mini-grid system control provided small variations in system frequency can be tolerated. The study was part of the DTI New and Renewable Energy Programme.

  16. Application of Impulse Control in Smart Grid Price System

    Directory of Open Access Journals (Sweden)

    Peng Du

    2013-07-01

    Full Text Available With the development of smart grid, flexible and interactive electricity market will finally emerge. Making full use of price can encourage consumers to use electricity during a low load period and reduce peak load, thus to guarantee electricity market stability. Impulse control is applied to price system in this paper. It is found that giving impulse control to price system can make the system reach stable state well, which is based on the theory of impulsive differential system. The sufficient condition for stable system and the max upper bound of impulse interval are also provided. The proposed method is proved to be feasible and effective by theoretically analysis and numerical simulation.

  17. Adapting a commercial power system simulator for smart grid based system study and vulnerability assessment

    Science.gov (United States)

    Navaratne, Uditha Sudheera

    The smart grid is the future of the power grid. Smart meters and the associated network play a major role in the distributed system of the smart grid. Advance Metering Infrastructure (AMI) can enhance the reliability of the grid, generate efficient energy management opportunities and many innovations around the future smart grid. These innovations involve intense research not only on the AMI network itself but as also on the influence an AMI network can have upon the rest of the power grid. This research describes a smart meter testbed with hardware in loop that can facilitate future research in an AMI network. The smart meters in the testbed were developed such that their functionality can be customized to simulate any given scenario such as integrating new hardware components into a smart meter or developing new encryption algorithms in firmware. These smart meters were integrated into the power system simulator to simulate the power flow variation in the power grid on different AMI activities. Each smart meter in the network also provides a communication interface to the home area network. This research delivers a testbed for emulating the AMI activities and monitoring their effect on the smart grid.

  18. Method and system for managing power grid data

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Jian; Akyol, Bora A.; Gorton, Ian

    2015-11-10

    A system and method of managing time-series data for smart grids is disclosed. Data is collected from a plurality of sensors. An index is modified for a newly created block. A one disk operation per read or write is performed. The one disk operation per read includes accessing and looking up the index to locate the data without movement of an arm of the disk, and obtaining the data. The one disk operation per write includes searching the disk for free space, calculating an offset, modifying the index, and writing the data contiguously into a block of the disk the index points to.

  19. Design and operation of grid-interactive thin-film silicon PV systems

    Science.gov (United States)

    Marion, Bill; Atmaram, Gobind; Lashway, Clin; Strachan, John W.

    Results are described from the operation of 11 thin-film amorphous silicon photovoltaic systems at three test facilities: the Florida Solar Energy Center, the New Mexico Solar Energy Institute, and Sandia National Laboratories. Commercially available modules from four US manufacturers are used in these systems, with array sizes from 133 to 750 W peak. Measured array efficiencies are from 3.1 to 4.8 percent. Except for one manufacturer, array peak power is in agreement with the calculated design ratings. For certain grid-connected systems, nonoptimal operation exists because the array peak power voltage is below the lower voltage limit of the power conditioning system. Reliability problems are found in two manufacturers' modules when shorts to ground and terminal corrosion occur. Array leakage current data are presented.

  20. SAUNA: A system for grid generation and flow simulation using hybrid structured/unstructured grids

    Science.gov (United States)

    Childs, P. N.; Shaw, J. A.; Peace, A. J.; Georgala, J. M.

    1992-05-01

    The development of a flow simulation facility for predicting the aerodynamics of complex configurations wherein the grid is composed of both structured and unstructured regions is described. Issues relating to the generation and analysis of such grids and to the accurate and efficient computation of both inviscid and viscous flows thereon are considered. Further the development of a comprehensive post-processing and visualization facility is explored. Techniques are illustrated throughout by application to realistic aircraft geometries.

  1. Methodology to determine the technical performance and value proposition for grid-scale energy storage systems :

    Energy Technology Data Exchange (ETDEWEB)

    Byrne, Raymond Harry; Loose, Verne William; Donnelly, Matthew K.; Trudnowski, Daniel J.

    2012-12-01

    As the amount of renewable generation increases, the inherent variability of wind and photovoltaic systems must be addressed in order to ensure the continued safe and reliable operation of the nation's electricity grid. Grid-scale energy storage systems are uniquely suited to address the variability of renewable generation and to provide other valuable grid services. The goal of this report is to quantify the technical performance required to provide di erent grid bene ts and to specify the proper techniques for estimating the value of grid-scale energy storage systems.

  2. Distributed operating system for NASA ground stations

    Science.gov (United States)

    Doyle, John F.

    1987-01-01

    NASA ground stations are characterized by ever changing support requirements, so application software is developed and modified on a continuing basis. A distributed operating system was designed to optimize the generation and maintenance of those applications. Unusual features include automatic program generation from detailed design graphs, on-line software modification in the testing phase, and the incorporation of a relational database within a real-time, distributed system.

  3. Distributed operating system for NASA ground stations

    Science.gov (United States)

    Doyle, John F.

    1987-01-01

    NASA ground stations are characterized by ever changing support requirements, so application software is developed and modified on a continuing basis. A distributed operating system was designed to optimize the generation and maintenance of those applications. Unusual features include automatic program generation from detailed design graphs, on-line software modification in the testing phase, and the incorporation of a relational database within a real-time, distributed system.

  4. Development of Phase Lock Loop System for Synchronisation of a Hybrid System with the Grid

    Directory of Open Access Journals (Sweden)

    A. S. Abubakar

    2016-06-01

    Full Text Available Phase locked loop (PLL is an important part of the control unit of the grid connected power converter. The method of zero crossing detection (ZCD does not produce accurate phase information when grid is non-ideal. In this work, a synchronous reference frame (SRF PLL method to obtain accurate phase information when the grid voltages are unbalanced is proposed. The performances of the PLL have been verified for ideal and abnormal grid conditions such as unbalance, voltage sag, faults condition etc. Based on the results obtained, the developed PLL gives better fault ride when unbalances in the three phase input signals are overall handled well by the PLL system as it locks the two signal back within the first cycle. It also overcomes a phase jump after 5 milli-seconds from the time the fault was introduced and performs better tracking of the grid voltage and that of the renewable energy source.

  5. Development of Phase Lock Loop System for Synchronisation of a Hybrid System with the Grid

    Directory of Open Access Journals (Sweden)

    A. S. Abubakar

    2016-12-01

    Full Text Available Phase locked loop (PLL is an important part of the control unit of the grid connected power converter. The method of zero crossing detection (ZCD does not produce accurate phase information when grid is non-ideal. In this work, a synchronous reference frame (SRF PLL method to obtain accurate phase information when the grid voltages are unbalanced is proposed. The performances of the PLL have been verified for ideal and abnormal grid conditions such as unbalance, voltage sag, faults condition etc. Based on the results obtained, the developed PLL gives better fault ride when unbalances in the three phase input signals are overall handled well by the PLL system as it locks the two signal back within the first cycle. It also overcomes a phase jump after 5 milli-seconds from the time the fault was introduced and performs better tracking of the grid voltage and that of the renewable energy source.

  6. Direct Control Implementation of a Refrigeration System in Smart Grid

    DEFF Research Database (Denmark)

    Pedersen, Rasmus; Schwensen, John; Sivabalan, Senthuran

    2013-01-01

    controlled smart grid, by use of a predictive control strategy. In this application the shift in consumption is used to stabilize a small grid by utilizing excess renewable energy to minimize the need for fossil fueled production sources. In order for the centralized grid controller to handle such a node...

  7. Equivalent Simplification Method of Micro-Grid

    Directory of Open Access Journals (Sweden)

    Cai Changchun

    2013-09-01

    Full Text Available The paper concentrates on the equivalent simplification method for the micro-grid system connection into distributed network. The equivalent simplification method proposed for interaction study between micro-grid and distributed network. Micro-grid network, composite load, gas turbine synchronous generation, wind generation are equivalent simplification and parallel connect into the point of common coupling. A micro-grid system is built and three phase and single phase grounded faults are performed for the test of the equivalent model of micro-grid. The simulation results show that the equivalent model of micro-grid is effective, and the dynamic of equivalent model is similar with the detailed model of micro-grid. The equivalent simplification method for the micro-grid network and distributed components is suitable for the study of micro-grid.  

  8. Application of smart grid in Kosovo power system

    Directory of Open Access Journals (Sweden)

    Arben Gjukaj

    2011-08-01

    Full Text Available The expansion of the electricity market and the reorganization of electricity companies (production, transmission, distribution, etc. require a supervision of electricity distribution network at all voltage levels. The main goal is supplying costumers with electricity in both quality and economical manner. This encourages us to establish the Smart Grid and SCADA system, so that the existing system will be monitored from the distance in a regular time and will be operated in order to carry out optimization, automation of control, and direction of key parameters of the distribution system. Further, the large number of facilities of all voltage levels, as well as, large number of planned and unplanned occurrences causes numerous operations and changes in the configuration of network distribution. Therefore, it is very important to supervise the distribution network from distance both, in technical and economical aspect. Accordingly, the automation of the network is the topic of all distribution companies in Kosovo too.

  9. Vehicle-to-Grid Power in Danish Electric Power Systems

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2009-01-01

    The integration of renewable energy systems is often constrained by the variable nature of their output. This demands for the services of storing the electricity generated from most of the renewable energy sources. Vehicle-to-grid (V2G) power could use the inherent energy storage of electric...... vehicles and its quick response time to balance and stabilize a power system with fluctuating power. This paper outlines the use of battery electric vehicles in supporting large-scale integration of renewable energy in the Danish electric power systems. The reserve power requirements for a high renewable...... energy penetration could be met by an amount of V2G based electric vehicles less than 10% of the total vehicle need in Denmark. The participation of electric vehicle in ancillary services would earn significant revenues to the vehicle owner. The power balancing services of electric vehicles...

  10. Vehicle-to-Grid Power in Danish Electric Power Systems

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2009-01-01

    The integration of renewable energy systems is often constrained by the variable nature of their output. This demands for the services of storing the electricity generated from most of the renewable energy sources. Vehicle-to-grid (V2G) power could use the inherent energy storage of electric...... vehicles and its quick response time to balance and stabilize a power system with fluctuating power. This paper outlines the use of battery electric vehicles in supporting large-scale integration of renewable energy in the Danish electric power systems. The reserve power requirements for a high renewable...... energy penetration could be met by an amount of V2G based electric vehicles less than 10% of the total vehicle need in Denmark. The participation of electric vehicle in ancillary services would earn significant revenues to the vehicle owner. The power balancing services of electric vehicles...

  11. Grid Harmonic and Control Delay Compensation for Three-phase Grid-connected VSIs in Small Wind Turbine Systems

    Institute of Scientific and Technical Information of China (English)

    Mary Kaye; Chris Diduch; Qing-rong ZENG; Idris Gadoura; Liu-chen ZHANG

    2011-01-01

    Voltage space vector pulse-width modulation(SVPWM) has been widely applied to control current in threephase vohage source inverters (VSI).However,as a voltage type modulator,SVPWM has certain drawbacks compared with current type modulators for grid-connected applications.For a grid-connected VSI,the performance of existing current controllers based on SVPWM is compromised by grid harmonics,control delay and system nonlinearities such as switching dead time.Moreover,unlike current type PWM,SVPWM does not inherently have over-current protection.A novel SVPWM-based current controller is proposed for three-phase grid-connected VSIs for small wind turbine applications.To overcome the drawbacks of SVPWM,a grid harmonic compensation method is proposed along with compensation for control delays.Both simulation and experimental results have established excellent steady-state response and fast dynamic response of the current controller.In addition,the DSP-based control system has both improved real-time control performance and fast response for over-current protection.

  12. Tables for the estimation of the internal rate of return of photovoltaic grid-connected systems

    Energy Technology Data Exchange (ETDEWEB)

    Talavera, D.L.; Nofuentes, G.; Aguilera, J.; Fuentes, M. [Grupo de Investigacion y Desarrollo de Energia Solar y Automatica, Escuela Politecnica Superior, University of Jaen, Campus de Las Lagunillas, s/n. 23071 Jaen (Spain)

    2007-04-15

    A continuous decrease trend in PV costs together with a wide variety of supporting measures have turned photovoltaic grid-connected systems (PVGCS) into a profitable investment when some economic conditions are met. The internal rate of return (IRR) is a meaningful parameter for prospective owners of these PV systems. Nevertheless, this parameter has to be estimated by means of non-analytical methods. This paper presents some easy-to-use tables addressed to estimate the IRR avoiding cumbersome calculations, which is an attractive feature for owners, marketers and designers. Firstly, current and near-term costs of PVGCS are reviewed, together with some financial incentives available at present. This introduces the economic scenario, where the tables are to be used. A short introduction to the economic analysis of these systems provides a solid ground to eventually present the tables intended to the estimation of the IRR. Lastly, three examples demonstrate the use of the tables. (author)

  13. Earth System Grid II, Turning Climate Datasets into Community Resources

    Energy Technology Data Exchange (ETDEWEB)

    Middleton, Don

    2006-08-01

    The Earth System Grid (ESG) II project, funded by the Department of Energy’s Scientific Discovery through Advanced Computing program, has transformed climate data into community resources. ESG II has accomplished this goal by creating a virtual collaborative environment that links climate centers and users around the world to models and data via a computing Grid, which is based on the Department of Energy’s supercomputing resources and the Internet. Our project’s success stems from partnerships between climate researchers and computer scientists to advance basic and applied research in the terrestrial, atmospheric, and oceanic sciences. By interfacing with other climate science projects, we have learned that commonly used methods to manage and remotely distribute data among related groups lack infrastructure and under-utilize existing technologies. Knowledge and expertise gained from ESG II have helped the climate community plan strategies to manage a rapidly growing data environment more effectively. Moreover, approaches and technologies developed under the ESG project have impacted datasimulation integration in other disciplines, such as astrophysics, molecular biology and materials science.

  14. Islanding Issues of Grid-connected PV Systems

    Directory of Open Access Journals (Sweden)

    S.Narendiran

    2013-04-01

    Full Text Available ‘Islanding’ is a term, which refers to the situation when the Distributed generator (DG continues to power the consumer-end even when the electrical power from the electric utility is no longerpresent. Islanding phenomenon occurs after the certain part of the utility grid gets disconnected from a large number of inter-connected PVs. It leads to troubles in voltage and frequency control and powerquality issues. Therefore there is a need for appropriate anti-islanding measures for grid-connected PV systems. There are two ways to defeat the islanding phenomenon, by reactor insertion method on utility side and capacitor insertion method on PV side. Some of the Islanding detection methods (IDMs are broadly classifies as Active, Passive and Utility based. Active mode of detection includes impedance measurement, slip mode frequency shift and frequency bias. Passive methods contain over/under voltage and frequency and harmonics detection. Utility-based methods consist of manual disconnection, SCADA, impedance insertion.

  15. Optimal collective communication algorithms in grid computing system

    Institute of Scientific and Technical Information of China (English)

    Wu Yanhui; Lu Xinda

    2005-01-01

    With computational grid, running parallel program on large-scale and geographically distributed computer systems is feasible. It is a difficult task to write parallel applications which may require changing the communication structure of the applications. MPI's collective operations allow for some of these changes to be hidden from the applications programmer. We have developed optimal collective communication algorithms optimized for wide area systems and have taken hierarchical network structure into account. Both the bandwidth and the latency of the LAN and WAN links differ by almost two orders of magnitude. Our algorithms are designed to send the minimal amount of data over the slow wide area links, and to only incur a single wide area latency. Compared to MPICH that do not consider the topology, large performance improvements are possible.

  16. Protection Method of Biological Lightning Safety around Power Grid Based on Grounding Electrode Structure

    Science.gov (United States)

    Sixiang, Chen; Daopin, Chen; Ming, Zhang; Xiao, Huang; Jian, He; Zhijie, He

    2017-05-01

    Aimed at the actual situation of fish death in fish ponds near the power transmission line towers after the thunderstorm happened in Guangdong Province in China, this paper studied the influence of the ground current on fish in the pond. Firstly, This paper studied the current density of the fish without protection. On this basis, paper studied the horizontal pole with full-shielded, the vertical pole with half-shielded, the horizontal pole with extension three kinds of protective measures and effects. Finally an effective protection scheme was put forward according to the engineering practice. The results can provide some engineering guidance and quantitative basis for the design and modification of grounding devices when the tower is adjacent to the fish ponds in southern China.

  17. Environmental impacts of large-scale grid-connected ground-mounted PV installations

    OpenAIRE

    Beylot, Antoine; Payet, Jérôme; Puech, Clément; Adra, Nadine; Jacquin, Philippe; Blanc, Isabelle; Beloin-Saint-Pierre, Didier

    2014-01-01

    World Renewable Energy Congress - Sweden, 8-13 May, 2011, Linköping, Sweden; International audience; This study characterizes the environmental performances of large-scale ground-mounted PV installations by considering a life cycle approach. The methodology is based on the application of the existing international standards of Life Cycle Assessment (LCA). Four scenarios are compared, considering fixed-mounting structures with (1) primary aluminum supports or (2) wood supports, and mobile stru...

  18. Environmental Impacts of Large-Scale Grid-Connected Ground-Mounted PV Installations

    OpenAIRE

    Beylot, Antoine; Payet, Jérôme; Puech, Clément; Adra, Nadine; Jacquin, Philippe; Blanc, Isabelle; Beloin-Saint-Pierre, Didier

    2011-01-01

    Available on: http://www.ep.liu.se/ecp/057/vol11/007/ecp57vol11_007.pdf; International audience; This study characterizes the environmental performances of large-scale ground-mounted PV installations by considering a life-cycle approach. The methodology is based on the application of the existing international standards of Life Cycle Assessment (LCA). Four scenarios are compared, considering fixedmounting structures with (1) primary aluminum supports or (2) wood supports, and mobile structure...

  19. Review of DC System Technologies for Large Scale Integration of Wind Energy Systems with Electricity Grids

    Directory of Open Access Journals (Sweden)

    Sheng Jie Shao

    2010-06-01

    Full Text Available The ever increasing development and availability of power electronic systems is the underpinning technology that enables large scale integration of wind generation plants with the electricity grid. As the size and power capacity of the wind turbine continues to increase, so is the need to place these significantly large structures at off-shore locations. DC grids and associated power transmission technologies provide opportunities for cost reduction and electricity grid impact minimization as the bulk power is concentrated at single point of entry. As a result, planning, optimization and impact can be studied and carefully controlled minimizing the risk of the investment as well as power system stability issues. This paper discusses the key technologies associated with DC grids for offshore wind farm applications.

  20. Computer Aided Design of Transformer Station Grounding System Using CDEGS Software

    Directory of Open Access Journals (Sweden)

    S. Nikolovski

    2004-01-01

    Full Text Available This paper presents a computer-aided design of a transformer station grounding system. Fault conditions in a transformer station can produce huge damage to transformer station equipment if the grounding system is not designed properly. A well designed grounding system is a very important part of the project for transformer station design as a whole. This paper analyses a procedure for transformer grounding system design and spatial distribution of touch and step voltage on the ground surface level, using the CDEGS (Current Distribution Electromagnetic Interference Grounding and Soil Structure Analysis software. Spatial distribution is needed for checking and finding dangerous step and touch voltages above and around the transformer station. Apparent earth resistivity data is measured and analyzed using the RESAP module of the CDEGS software. Because of the very high current flow into the grounding system during a single line to ground fault or a three phase fault in the transformer station, very high and dangerous potentials can be induced on the metallic structures including the fence, which can cause dangerous situations for people and animals near the station and for the personnel inside the station. The PLOT module of CDEGS is used to view the results of the scalar potential, step and touch voltage on the surface. Graphic displays include equipotent contour lines and potential profiles (gradients in 3D and 2D perspective and apparent soil resistivity (Wm versus inter electrode spacing (m. The results of alternative grid designs may be displayed simultaneously for the purpose of comparison.

  1. Implementation of a Wind Farm Turbine Control System with Short-Term Grid Faults Management

    DEFF Research Database (Denmark)

    Marra, Francesco; Rasmussen, Tonny Wederberg; Garcia-Valle, Rodrigo

    2010-01-01

    The increased penetration of wind power in the grid has led to important technical barriers that limit the development, where the stability of the system plays a key issue. Grid operators in different countries are issuing new grid requirements, the so-called grid codes that impose more...... restrictions for the wind turbines behavior especially under grid faults. Wind turbines are requested to stay connected even during faults. These new requirements are challenging the control of the wind turbines and new control strategies are required to meet the target. This paper dealt...... with the implementation of a control strategy in order to stay connected under grid faults. The method aimed to ensure that a wind farm turbine remains connected and no electric power is delivered to the grid during the fault period. The overall system was modelled and simulated by using the software Matlab/Simulink....

  2. Study of Security Attributes of Smart Grid Systems- Current Cyber Security Issues

    Energy Technology Data Exchange (ETDEWEB)

    Wayne F. Boyer; Scott A. McBride

    2009-04-01

    This document provides information for a report to congress on Smart Grid security as required by Section 1309 of Title XIII of the Energy Independence and Security Act of 2007. The security of any future Smart Grid is dependent on successfully addressing the cyber security issues associated with the nation’s current power grid. Smart Grid will utilize numerous legacy systems and technologies that are currently installed. Therefore, known vulnerabilities in these legacy systems must be remediated and associated risks mitigated in order to increase the security and success of the Smart Grid. The implementation of Smart Grid will include the deployment of many new technologies and multiple communication infrastructures. This report describes the main technologies that support Smart Grid and summarizes the status of implementation into the existing U.S. electrical infrastructure.

  3. A Harmonic Impedance Measurement System for Reduction of Harmonics in the Electricity Grid

    NARCIS (Netherlands)

    Heskes, P.J.M.; Myrzik, J.M.A.; Kling, W.L.

    2009-01-01

    This paper describes the development of a Complex Harmonic Impedance Measurement system, called the CHIME-system. This system performs on-line impedance measurements in the electricity grid and will be designed for implementation in Digital Signal Processor (DSP) control systems of grid-connected el

  4. Model of interaction in Smart Grid on the basis of multi-agent system

    Science.gov (United States)

    Engel, E. A.; Kovalev, I. V.; Engel, N. E.

    2016-11-01

    This paper presents model of interaction in Smart Grid on the basis of multi-agent system. The use of travelling waves in the multi-agent system describes the behavior of the Smart Grid from the local point, which is being the complement of the conventional approach. The simulation results show that the absorption of the wave in the distributed multi-agent systems is effectively simulated the interaction in Smart Grid.

  5. Performance Of Microturbine Generation System in Grid Connected and Islanding Modes of Operation

    OpenAIRE

    Gaonkar, Dattatraya N.

    2010-01-01

    The Distributed generation based on microturbine technology is new and a fast growing business. These DG systems are quickly becoming an energy management solution that saves money, resources, and environment in one compact and scalable package- be it stationary or mobile, remote or interconnected with the utility grid. In this thesis the MTG system model suitable for grid connected and islanding operation has been presented.The detailed modeling of a single-shaft MTG system suitable for grid...

  6. Death Valley regional ground-water flow system, Nevada and California -- hydrogeologic framework and transient ground-water flow model

    Science.gov (United States)

    : Belcher, Wayne R.

    2004-01-01

    provided by acquiring additional data, by reevaluating existing data using current technology and concepts, and by refining earlier interpretations to reflect the current understanding of the regional ground-water flow system. Ground-water flow in the Death Valley region is composed of several interconnected, complex ground-water flow systems. Ground-water flow occurs in three subregions in relatively shallow and localized flow paths that are superimposed on deeper, regional flow paths. Regional ground-water flow is predominantly through a thick Paleozoic carbonate rock sequence affected by complex geologic structures from regional faulting and fracturing that can enhance or impede flow. Spring flow and evapotranspiration (ET) are the dominant natural ground-water discharge processes. Ground water also is withdrawn for agricultural, commercial, and domestic uses. Ground-water flow in the DVRFS was simulated using MODFLOW-2000, a 3D finite-difference modular ground-water flow modeling code that incorporates a nonlinear least-squares regression technique to estimate aquifer parameters. The DVRFS model has 16 layers of defined thickness, a finite-difference grid consisting of 194 rows and 160 columns, and uniform cells 1,500 m on each side. Prepumping conditions (before 1913) were used as the initial conditions for the transient-state calibration. The model uses annual stress periods with discrete recharge and discharge components. Recharge occurs mostly from infiltration of precipitation and runoff on high mountain ranges and from a small amount of underflow from adjacent basins. Discharge occurs primarily through ET and spring discharge (both simulated as drains) and water withdrawal by pumping and, to a lesser amount, by underflow to adjacent basins, also simulated by drains. All parameter values estimated by the regression are reasonable and within the range of expected values. The simulated hydraulic heads of the final calibrated transient model gener

  7. Distributed Computation Resources for Earth System Grid Federation (ESGF)

    Science.gov (United States)

    Duffy, D.; Doutriaux, C.; Williams, D. N.

    2014-12-01

    The Intergovernmental Panel on Climate Change (IPCC), prompted by the United Nations General Assembly, has published a series of papers in their Fifth Assessment Report (AR5) on processes, impacts, and mitigations of climate change in 2013. The science used in these reports was generated by an international group of domain experts. They studied various scenarios of climate change through the use of highly complex computer models to simulate the Earth's climate over long periods of time. The resulting total data of approximately five petabytes are stored in a distributed data grid known as the Earth System Grid Federation (ESGF). Through the ESGF, consumers of the data can find and download data with limited capabilities for server-side processing. The Sixth Assessment Report (AR6) is already in the planning stages and is estimated to create as much as two orders of magnitude more data than the AR5 distributed archive. It is clear that data analysis capabilities currently in use will be inadequate to allow for the necessary science to be done with AR6 data—the data will just be too big. A major paradigm shift from downloading data to local systems to perform data analytics must evolve to moving the analysis routines to the data and performing these computations on distributed platforms. In preparation for this need, the ESGF has started a Compute Working Team (CWT) to create solutions that allow users to perform distributed, high-performance data analytics on the AR6 data. The team will be designing and developing a general Application Programming Interface (API) to enable highly parallel, server-side processing throughout the ESGF data grid. This API will be integrated with multiple analysis and visualization tools, such as the Ultrascale Visualization Climate Data Analysis Tools (UV-CDAT), netCDF Operator (NCO), and others. This presentation will provide an update on the ESGF CWT's overall approach toward enabling the necessary storage proximal computational

  8. Modified Multilevel Inverter Topology for Grid Connected Pv Systems

    Directory of Open Access Journals (Sweden)

    Dhivya Balakrishnan

    2013-10-01

    Full Text Available Multilevel converters offer high power capability, associated with lower output harmonics and lower commutation losses. Their main disadvantage is their complexity, requiring a great number of power devices and passive components, and a rather complex control circuitry. This paper proposes a single-phase seven- level inverter for grid connected PV systems, with a novel pulse width-modulated (PWM control scheme. Three reference signals that are identical to each other with an offset that is equivalent to the amplitude of the triangular carrier signal were used to generate the PWM signals. The inverter is capable of producing seven levels of output-voltage levels from the dc supply voltage. This paper proposes a new multilevel inverter topology using an H-bridge output stage with two bidirectional auxiliary switches. The new topology produces a significant reduction in the number of power devices and capacitors required to implement a multilevel output using the Asymmetric Cascade configuration.

  9. River Debris Management System using Off-Grid Photovoltaic Module

    Directory of Open Access Journals (Sweden)

    Saadon Intan Mastura

    2017-01-01

    Full Text Available In Malaysia, Malacca River has long been the tourism attraction in Malacca. However, due to negligence, the river has been polluted by the litters thrown by tourists and even local residents, thus reflects a negative perception on Malacca. Therefore, this paper discusses about a fully automated river debris management system development using a stand-alone photovoltaic system. The concept design is to be stand alone in the river and automatically pull debris towards it for disposal. An off-grid stand-alone photovoltaic solar panel is used as renewable energy source connected to water pump and Arduino Uno microcontroller. The water pump rotates a water wheel and at the same time moves a conveyor belt; which is connected to the water wheel by a gear for debris collection. The solar system sizing suitable for the whole system is shown in this paper. The dumpster barge is equipped with an infrared sensor to monitor maximum height for debris, and instruct Arduino Uno to turn off the water pump. This system is able to power up using solar energy on sunny days and using battery otherwise.

  10. 46 CFR 111.05-31 - Grounding conductors for systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Grounding conductors for systems. 111.05-31 Section 111... Grounding conductors for systems. (a) A conductor for grounding a direct-current system must be the larger of: (1) The largest conductor supplying the system; or (2) No. 8 AWG (8.4mm2). (b) A conductor...

  11. Foundational Report Series. Advanced Distribution management Systems for Grid Modernization (Importance of DMS for Distribution Grid Modernization)

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jianhui [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-01

    Grid modernization is transforming the operation and management of electric distribution systems from manual, paper-driven business processes to electronic, computer-assisted decisionmaking. At the center of this business transformation is the distribution management system (DMS), which provides a foundation from which optimal levels of performance can be achieved in an increasingly complex business and operating environment. Electric distribution utilities are facing many new challenges that are dramatically increasing the complexity of operating and managing the electric distribution system: growing customer expectations for service reliability and power quality, pressure to achieve better efficiency and utilization of existing distribution system assets, and reduction of greenhouse gas emissions by accommodating high penetration levels of distributed generating resources powered by renewable energy sources (wind, solar, etc.). Recent “storm of the century” events in the northeastern United States and the lengthy power outages and customer hardships that followed have greatly elevated the need to make power delivery systems more resilient to major storm events and to provide a more effective electric utility response during such regional power grid emergencies. Despite these newly emerging challenges for electric distribution system operators, only a small percentage of electric utilities have actually implemented a DMS. This paper discusses reasons why a DMS is needed and why the DMS may emerge as a mission-critical system that will soon be considered essential as electric utilities roll out their grid modernization strategies.

  12. Grid-Search Location Methods for Ground-Truth Collection from Local and Regional Seismic Networks

    Energy Technology Data Exchange (ETDEWEB)

    Schultz, C A; Rodi, W; Myers, S C

    2003-07-24

    The objective of this project is to develop improved seismic event location techniques that can be used to generate more and better quality reference events using data from local and regional seismic networks. Their approach is to extend existing methods of multiple-event location with more general models of the errors affecting seismic arrival time data, including picking errors and errors in model-based travel-times (path corrections). Toward this end, they are integrating a grid-search based algorithm for multiple-event location (GMEL) with a new parameterization of travel-time corrections and new kriging method for estimating the correction parameters from observed travel-time residuals. Like several other multiple-event location algorithms, GMEL currently assumes event-independent path corrections and is thus restricted to small event clusters. The new parameterization assumes that travel-time corrections are a function of both the event and station location, and builds in source-receiver reciprocity and correlation between the corrections from proximate paths as constraints. The new kriging method simultaneously interpolates travel-time residuals from multiple stations and events to estimate the correction parameters as functions of position. They are currently developing the algorithmic extensions to GMEL needed to combine the new parameterization and kriging method with the simultaneous location of events. The result will be a multiple-event location method which is applicable to non-clustered, spatially well-distributed events. They are applying the existing components of the new multiple-event location method to a data set of regional and local arrival times from Nevada Test Site (NTS) explosions with known origin parameters. Preliminary results show the feasibility and potential benefits of combining the location and kriging techniques. They also show some preliminary work on generalizing of the error model used in GMEL with the use of mixture

  13. Grid-Search Location Methods for Ground-Truth Collection From Local and Regional Seismic Networks

    Energy Technology Data Exchange (ETDEWEB)

    William Rodi; Craig A. Schultz; Gardar Johannesson; Stephen C. Myers

    2005-05-13

    This project investigated new techniques for improving seismic event locations derived from regional and local networks. The technqiues include a new approach to empirical travel-time calibration that simultaneously fits data from multiple stations and events, using a generalization of the kriging method, and predicts travel-time corrections for arbitrary event-station paths. We combined this calibration approach with grid-search event location to produce a prototype new multiple-event location method that allows the use of spatially well-distributed events and takes into account correlations between the travel-time corrections from proximate event-station paths. Preliminary tests with a high quality data set from Nevada Test Site explosions indicated that our new calibration/location method offers improvement over the conventional multiple-event location methods now in common use, and is applicable to more general event-station geometries than the conventional methods. The tests were limited, however, and further research is needed to fully evaluate, and improve, the approach. Our project also demonstrated the importance of using a realistic model for observational errors in an event location procedure. We took the initial steps in developing a new error model based on mixture-of-Gaussians probability distributions, which possess the properties necessary to characterize the complex arrival time error processes that can occur when picking low signal-to-noise arrivals. We investigated various inference methods for fitting these distributions to observed travel-time residuals, including a Markov Chain Monte Carlo technique for computing Bayesian estimates of the distribution parameters.

  14. Simulation of wind power with front-end converter into interconnected grid system

    Directory of Open Access Journals (Sweden)

    Sharad W. Mohod

    2009-09-01

    Full Text Available In the growing electricity supply industry and open access market for electricity worldwide, renewable sources are getting added into the grid system. This affects the grid power quality. To assess the impact on grid due to wind energy integration, the knowledge of electrical characteristic of wind turbine and associated control equipments are required. The paper presents a simulation set-up for wind turbine in MATLAB / SIMULINK, with front end converter and interconnected system. The presented control scheme provides the wind power flow to the grid through a converter. The injected power in the system at the point of common coupling is ensured within the power quality norms.

  15. Selection of Model in Developing Information Security Criteria for Smart Grid Security System

    CERN Document Server

    Ling, Amy Poh Ai

    2011-01-01

    At present, the "Smart Grid" has emerged as one of the best advanced energy supply chains. This paper looks into the security system of smart grid via the smart planet system. The scope focused on information security criteria that impact on consumer trust and satisfaction. The importance of information security criteria is perceived as the main aspect to impact on customer trust throughout the entire smart grid system. On one hand, this paper also focuses on the selection of the model for developing information security criteria on a smart grid.

  16. State-space-based harmonic stability assessment of paralleled grid-connected inverters system

    DEFF Research Database (Denmark)

    Wang, Yanbo; Wang, Xiongfei; Chen, Zhe;

    2016-01-01

    model of paralleled grid-connected inverters is built. Finally, the state space-based stability analysis approach is developed to explain the harmonic resonance phenomenon. The eigenvalue traces associated with time delay and coupled grid impedance are obtained, which accounts for how the unstable......This paper addresses a state-space-based harmonic stability analysis of paralleled grid-connected inverters system. A small signal model of individual inverter is developed, where LCL filter, the equivalent delay of control system, and current controller are modeled. Then, the overall small signal...... inverter produces the harmonic resonance and leads to the instability of whole paralleled system. The proposed approach reveals the contributions of the grid impedance as well as the coupled effect on other grid-connected inverters under different grid conditions. Simulation and experimental results...

  17. 40 CFR 257.22 - Ground-water monitoring systems.

    Science.gov (United States)

    2010-07-01

    ... operator. When physical obstacles preclude installation of ground-water monitoring wells at the relevant... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground-water monitoring systems. 257... Waste Disposal Units Ground-Water Monitoring and Corrective Action § 257.22 Ground-water......

  18. Grid Monitoring and Advanced Control of Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian Vasile

    . First part of the thesis investigates possible algorithms for fast and accurate identi cation of utility network variables such as voltage amplitude, frequency, phase angle and line impedance. Special attention has been paid to grid synchronization algorithm in terms of accurate estimation of grid...... of grid voltage and the frequency of utility network. As a result, fast and accurate identi cation of both variables has been achieved. In addition, positive and negative sequence components of grid voltage can also be calculated. Simple, yet powerful ltering techniques, based on second order generalized...... integrator (SOGI) and delay signal cancellation (DSC) have been used to separate the sequence components. Simulation and experimental results attest the accuracy and e ectiveness of the developed algorithms in identifying the frequency, phase angle and magnitude of grid voltages during severe distortions...

  19. Grid Inertial Response with Lithium-ion Battery Energy Storage Systems

    DEFF Research Database (Denmark)

    Knap, Vaclav; Sinha, Rakesh; Swierczynski, Maciej Jozef

    2014-01-01

    of this paper is to evaluate the technical viability of utilizing energy storage systems based on Lithium-ion batteries for providing inertial response in grids with high penetration levels of wind power. In order to perform this evaluation, the 12-bus system grid model was used; the inertia of the grid...... was varied by decreasing the number of conventional power plants in the studied grid model while in the same time increasing the load and the wind power penetration levels. Moreover, in order to perform a realistic investigation, a dynamic model of the Lithium-ion battery was considered and parameterized...

  20. Smart Grids – selected objectives and directions of distribution system operator actions

    Directory of Open Access Journals (Sweden)

    Rafał Czyżewski

    2012-03-01

    Full Text Available The paper presents various aspects of the implementation of Smart Grids from the distribution system operator standpoint. It discusses legal conditions of the Smart Grids implementation and their impact on the implementation timing. It describes the current state of the distribution grid and operations management systems infrastructure, indicating the desired direction of their development. It describes the preferred model of interrelations between grid operators and other key stakeholders, especially in the context of the expected establishment of balancing areas. It points out to the relevance of standardization and to the assurance of security of implemented Smart Grid solutions. It also specifies the barriers, which in the authors’ opinion could impede the Smart Grids deployment.

  1. Using Cloud-to-Ground Lightning Climatologies to Initialize Gridded Lightning Threat Forecasts for East Central Florida

    Science.gov (United States)

    Lambert, Winnie; Sharp, David; Spratt, Scott; Volkmer, Matthew

    2005-01-01

    Each morning, the forecasters at the National Weather Service in Melbourn, FL (NWS MLB) produce an experimental cloud-to-ground (CG) lightning threat index map for their county warning area (CWA) that is posted to their web site (http://www.srh.weather.gov/mlb/ghwo/lightning.shtml) . Given the hazardous nature of lightning in central Florida, especially during the warm season months of May-September, these maps help users factor the threat of lightning, relative to their location, into their daily plans. The maps are color-coded in five levels from Very Low to Extreme, with threat level definitions based on the probability of lightning occurrence and the expected amount of CG activity. On a day in which thunderstorms are expected, there are typically two or more threat levels depicted spatially across the CWA. The locations of relative lightning threat maxima and minima often depend on the position and orientation of the low-level ridge axis, forecast propagation and interaction of sea/lake/outflow boundaries, expected evolution of moisture and stability fields, and other factors that can influence the spatial distribution of thunderstorms over the CWA. The lightning threat index maps are issued for the 24-hour period beginning at 1200 UTC (0700 AM EST) each day with a grid resolution of 5 km x 5 km. Product preparation is performed on the AWIPS Graphical Forecast Editor (GFE), which is the standard NWS platform for graphical editing. Currently, the forecasters create each map manually, starting with a blank map. To improve efficiency of the forecast process, NWS MLB requested that the Applied Meteorology Unit (AMU) create gridded warm season lightning climatologies that could be used as first-guess inputs to initialize lightning threat index maps. The gridded values requested included CG strike densities and frequency of occurrence stratified by synoptic-scale flow regime. The intent is to increase consistency between forecasters while enabling them to focus on

  2. Electricity tariff systems for informatics system design regarding consumption optimization in smart grids

    Directory of Open Access Journals (Sweden)

    Simona Vasilica OPREA

    2016-01-01

    Full Text Available High volume of data is gathered via sensors and recorded by smart meters. These data are processed at the electricity consumer and grid operators' side by big data analytics. Electricity consumption optimization offers multiple advantages for both consumers and grid operators. At the electricity customer level, by optimizing electricity consumption savings are significant, but the main benefits will come from indirect aspects such as avoiding onerous grid investments, higher volume of renewable energy sources' integration, less polluted environment etc. In order to optimize electricity consumption, advanced tariff systems are essential due to the financial incentive they provide for electricity consumers' behaviour change. In this paper several advanced tariff systems are described in details. These systems are applied in England, Spain, Italy, France, Norway and Germany. These systems are compared from characteristics, advantages/disadvantages point of view. Then, different tariff systems applied in Romania are presented. Romanian tariff systems have been designed for various electricity consumers' types. Different tariff systems applied by grid operators or electricity suppliers will be included in the database model that is part of an informatics system for electricity consumption optimization.

  3. In Situ Measurement of the Undisturbed Ground Temperature for Ground Source Heat Pump System

    Institute of Scientific and Technical Information of China (English)

    ZHOU Ya-su

    2008-01-01

    The undisturbed ground are important for design of the ground heat exchangers in ground source heat pump (GSHP) systems. In this paper, the undisturbed ground temperatures measured in two different methods are presented. The investigation was carried out in two cases. The temperature measured with the direct method is assumed to give the correct undisturbed ground temperature profile. The temperature measured with indirect method overestimates the undisturbed ground temperature by 2.1℃ and 1.7℃. This difference is mainly caused by the circulation pump and ambient air to the fluid. Therefore, the results that are decreased about 2℃ as compared with the indirect measured are recommended to estimate the undisturbed ground temperature in situ measuring. A smaller pump or deeper borehole or mild weather would result in a more correct temperature. Because the undisturbed ground temperature is affected by many factors. Whether or not these conclusions are correct to other areas, this would need further investigation.

  4. Design and Analysis of the Poloidal Field Grid Power Supply System for the HT-7 Tokamak

    Institute of Scientific and Technical Information of China (English)

    2005-01-01

    This paper reports a new project - the poloidal field (PF) grid power supply system to replace the ac flywheel generator power supply system on the basis of the present running parameters of the HT-7 poloidal field and the short-circuit capacity of our transformer substation.The designed parameters of the PF grid power supply system have been verified to meet the requirements of the heating field (HF) and the vertical field (VF). In the meantime, in order to reduce the disturbance to the local power grid, the device of reactive power and harmonic current compensation has been added. Experimental results have confirmed the feasibility of the PF grid power supply system. Compared with the ac flywheel generator, the PF grid power supply system has the advantages of lower noise, precise control, convenient maintenance, simple operation and cost savings.

  5. Battery Energy Storage System (BESS) and Battery Management System (BMS) for Grid-Scale Applications

    Energy Technology Data Exchange (ETDEWEB)

    Lawder, M. T.; Suthar, B.; Northrop, P. W. C.; De, S.; Hoff, C. M.; Leitermann, O.; Crow, M. L.; Santhanagopalan, S.; Subramanian, V. R.

    2014-05-07

    The current electric grid is an inefficient system that wastes significant amounts of the electricity it produces because there is a disconnect between the amount of energy consumers require and the amount of energy produced from generation sources. Power plants typically produce more power than necessary to ensure adequate power quality. By taking advantage of energy storage within the grid, many of these inefficiencies can be removed. Advanced modeling is required when using battery energy storage systems (BESS) for grid storage in order to accurately monitor and control the storage system. Battery management systems (BMS) control how the storage system will be used and a BMS that utilizes advanced physics-based models will offer for much more robust operation of the storage system. The paper outlines the current state of the art for modeling in BMS and the advanced models required to fully utilize BMS for both lithium-ion batteries and vanadium redox-flow batteries. In addition, system architecture and how it can be useful in monitoring and control is discussed. A pathway for advancing BMS to better utilize BESS for grid-scale applications is outlined.

  6. Complete coverage of space favors modularity of the grid system in the brain

    Science.gov (United States)

    Sanzeni, A.; Balasubramanian, V.; Tiana, G.; Vergassola, M.

    2016-12-01

    Grid cells in the entorhinal cortex fire when animals that are exploring a certain region of space occupy the vertices of a triangular grid that spans the environment. Different neurons feature triangular grids that differ in their properties of periodicity, orientation, and ellipticity. Taken together, these grids allow the animal to maintain an internal, mental representation of physical space. Experiments show that grid cells are modular, i.e., there are groups of neurons which have grids with similar periodicity, orientation, and ellipticity. We use statistical physics methods to derive a relation between variability of the properties of the grids within a module and the range of space that can be covered completely (i.e., without gaps) by the grid system with high probability. Larger variability shrinks the range of representation, providing a functional rationale for the experimentally observed comodularity of grid cell periodicity, orientation, and ellipticity. We obtain a scaling relation between the number of neurons and the period of a module, given the variability and coverage range. Specifically, we predict how many more neurons are required at smaller grid scales than at larger ones.

  7. Flexible Mode Control of Grid Connected Wind Energy Conversion System Using Wavelet

    Directory of Open Access Journals (Sweden)

    Bhavna Jain

    2015-01-01

    Full Text Available Small wind turbine systems offer services to critical loads during grid faults and also connected back to grid in normal condition. The connection of a wind energy conversion system to the grid requires a robust phase locked loop (PLL and continuous monitoring of the grid conditions such as overvoltage, undervoltage, overfrequency, underfrequency, and grid outages. This paper describes a flexible control operation to operate a small wind turbine in both stand-alone mode via planned islanding and grid connected mode as well. In particular, a proper monitoring and control algorithm is required for transition between the modes. A wavelet based energy function is used for detection of grid disturbances as well as recovery of grid so that transition between the modes is made. To obtain good power quality LCL filter is used to reduce ripples. PLL is used for synchronization whenever mode changes from stand-alone to grid connected. Simulation results from a 10 kW wind energy conversion system are included to show the usefulness of the proposed methods. The control method is tested by generated gate pulses for single phase bridge inverter using field programmable gate array (FPGA.

  8. JPSS Common Ground System Multimission Support

    Science.gov (United States)

    Jamilkowski, M. L.; Miller, S. W.; Grant, K. D.

    2013-12-01

    NOAA & NASA jointly acquire the next-generation civilian operational weather satellite: Joint Polar Satellite System (JPSS). JPSS contributes the afternoon orbit & restructured NPOESS ground system (GS) to replace the current Polar-orbiting Operational Environmental Satellite (POES) system run by NOAA. JPSS sensors will collect meteorological, oceanographic, climatological & solar-geophysical observations of the earth, atmosphere & space. The JPSS GS is the Common Ground System (CGS), consisting of Command, Control, & Communications (C3S) and Interface Data Processing (IDPS) segments, both developed by Raytheon Intelligence, Information & Services (IIS). CGS now flies the Suomi National Polar-orbiting Partnership (S-NPP) satellite, transfers its mission data between ground facilities and processes its data into Environmental Data Records for NOAA & Defense (DoD) weather centers. CGS will expand to support JPSS-1 in 2017. The JPSS CGS currently does data processing (DP) for S-NPP, creating multiple TBs/day across over two dozen environmental data products (EDPs). The workload doubles after JPSS-1 launch. But CGS goes well beyond S-NPP & JPSS mission management & DP by providing data routing support to operational centers & missions worldwide. The CGS supports several other missions: It also provides raw data acquisition, routing & some DP for GCOM-W1. The CGS does data routing for numerous other missions & systems, including USN's Coriolis/Windsat, NASA's SCaN network (including EOS), NSF's McMurdo Station communications, Defense Meteorological Satellite Program (DMSP), and NOAA's POES & EUMETSAT's MetOp satellites. Each of these satellite systems orbits the Earth 14 times/day, downlinking data once or twice/orbit at up to 100s of MBs/second, to support the creation of 10s of TBs of data/day across 100s of EDPs. Raytheon and the US government invested much in Raytheon's mission-management, command & control and data-processing products & capabilities. CGS's flexible

  9. Increased Productivity for Emerging Grid Applications the Application Support System

    CERN Document Server

    Maier, Andrew; Mendez Lorenzo, Patricia; Moscicki, Jakub; Lamanna, Massimo; Muraru, Adrian

    2008-01-01

    Recently a growing number of various applications have been quickly and successfully enabled on the Grid by the CERN Grid application support team. This allowed the applications to achieve and publish large-scale results in a short time which otherwise would not be possible. We present the general infrastructure, support procedures and tools that have been developed. We discuss the general patterns observed in supporting new applications and porting them to the EGEE environment. The CERN Grid application support team has been working with the following real-life applications: medical and particle physics simulation (Geant4, Garfield), satellite imaging and geographic information for humanitarian relief operations (UNOSAT), telecommunications (ITU), theoretical physics (Lattice QCD, Feynman-loop evaluation), Bio-informatics (Avian Flu Data Challenge), commercial imaging processing and classification (Imense Ltd.) and physics experiments (ATLAS, LHCb, HARP). Using the EGEE Grid we created a standard infrastruct...

  10. Finite Element Modeling of Unbounded Grounding System Considering Soil Ionization Characteristic

    Institute of Scientific and Technical Information of China (English)

    CHEN Lin; LI Jingli; YANG Qing; SIMA Wenxia; SUN Caixin

    2012-01-01

    The aim of this paper is to calculate accurately the grounding performance of an unbounded grounding system under high-magnitude fault current.In this work,a finite element model is presented to compute the characteristic parameters of the grounding system in frequency domain.The ionization phenomenon in the soil surrounding the grounding electrode is taken into account by setting the resistivity of every soil element while the resistivity of each element is varying with the electric field intensity;not a priori hypothesis on the geometrical shape of the ionized region around the electrodes has to be enforced.Open boundaries of the grounding system are represented by introducing a spatial transformation formulation,which translates the semi-infinite space into the finite space without shortening the domain as in the traditional approach.The suggested modeling is validated by comparison of the calculated results,which are laid out for grounding rod and grounding grid,with experimental and simulation results found in literature.

  11. Design issues for grid-connected photovoltaic systems

    Science.gov (United States)

    Ropp, Michael Eugene

    1998-08-01

    Photovoltaics (PV) is the direct conversion of sunlight to electrical energy. In areas without centralized utility grids, the benefits of PV easily overshadow the present shortcomings of the technology. However, in locations with centralized utility systems, significant technical challenges remain before utility-interactive PV (UIPV) systems can be integrated into the mix of electricity sources. One challenge is that the needed computer design tools for optimal design of PV systems with curved PV arrays are not available, and even those that are available do not facilitate monitoring of the system once it is built. Another arises from the issue of islanding. Islanding occurs when a UIPV system continues to energize a section of a utility system after that section has been isolated from the utility voltage source. Islanding, which is potentially dangerous to both personnel and equipment, is difficult to prevent completely. The work contained within this thesis targets both of these technical challenges. In Task 1, a method for modeling a PV system with a curved PV array using only existing computer software is developed. This methodology also facilitates comparison of measured and modeled data for use in system monitoring. The procedure is applied to the Georgia Tech Aquatic Center (GTAC) FV system. In the work contained under Task 2, islanding prevention is considered. The existing state-of-the- art is thoroughly reviewed. In Subtask 2.1, an analysis is performed which suggests that standard protective relays are in fact insufficient to guarantee protection against islanding. In Subtask 2.2. several existing islanding prevention methods are compared in a novel way. The superiority of this new comparison over those used previously is demonstrated. A new islanding prevention method is the subject under Subtask 2.3. It is shown that it does not compare favorably with other existing techniques. However, in Subtask 2.4, a novel method for dramatically improving this new

  12. Evolutionary Hierarchical Multi-Criteria Metaheuristics for Scheduling in Large-Scale Grid Systems

    CERN Document Server

    Kołodziej, Joanna

    2012-01-01

    One of the most challenging issues in modelling today's large-scale computational systems is to effectively manage highly parametrised distributed environments such as computational grids, clouds, ad hoc networks and P2P networks. Next-generation computational grids must provide a wide range of services and high performance computing infrastructures. Various types of information and data processed in the large-scale dynamic grid environment may be incomplete, imprecise, and fragmented, which complicates the specification of proper evaluation criteria and which affects both the availability of resources and the final collective decisions of users. The complexity of grid architectures and grid management may also contribute towards higher energy consumption. All of these issues necessitate the development of intelligent resource management techniques, which are capable of capturing all of this complexity and optimising meaningful metrics for a wide range of grid applications.   This book covers hot topics in t...

  13. Novel deadbeat power control strategy for grid connected systems

    Directory of Open Access Journals (Sweden)

    Yousry Atia

    2015-09-01

    Full Text Available This paper introduces a novel approach for power control of three phase voltage source inverter (VSI in grid connected distribution generation system. In this approach, the control of active and reactive power is based on deadbeat control strategy. First, the difference between the reference and actual currents are introduced in different approach. Then current to power substitutions are carried out to obtain direct relationship between the required inverter voltage and instantaneous power errors. There is no need for coordinate transformation or PLL, where the required inverter voltage vector calculations carried out in α–β stationary reference frame. The proposed technique introduces two cross coupling components in the control function. Including these two components, the controller can achieve nearly zero steady-state tracking error of the controlled variables. To obtain fixed switching frequency operations, space vector modulation (SVM is used to synthesize the required inverter voltage vector and to generate the switching pulses for the VSI. The proposed strategy has the simplicity of the direct power control (DPC technique and doesn’t require any current control loops. The proposed strategy is experimentally implemented using fixed-point microcontroller. Simulation and experimental results are presented to confirm the superiority of the proposed strategy.

  14. Scaling the Earth System Grid to 100Gbps Networks

    Energy Technology Data Exchange (ETDEWEB)

    Balman, Mehmet [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sim, Alex [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-03-02

    The SC11 demonstration, titled Scaling the Earth System Grid to 100Gbps Networks, showed the ability to use underlying infrastructure for the movement of climate data over 100Gbps network. Climate change research is one of the critical data intensive sciences, and the amount of data is continuously growing. Climate simulation data is geographically distributed over the world, and it needs to be accessed from many sources for fast and efficient analysis and inter-comparison of simulations. We used a 100Gbps link connecting National Energy Research Scientific Computing Center (NERSC) at Lawrence Berkeley National Laboratory (LBNL), Argonne National Laboratory (ANL) and Oak Ridge National Laboratory (ORNL). In the demo, the Intergovernmental Panel on Climate Change (IPCC) Fourth Assessment Report (AR4) phase 3 of the Coupled Model Intercomparison Project (CMIP-3) dataset was staged into the memory of computing nodes at ANL and ORNL from NERSC over the 100Gbps network for analysis and visualization. In general, climate simulation data consists of relatively small and large files with irregular file size distribution in each dataset. In this demo, we addressed challenges on data management in terms of high bandwidth networks, usability of existing protocols and middleware tools, and how applications can adapt and benefit from next generation networks.

  15. Distributing reanalysis data on the Earth System Grid Federation

    Science.gov (United States)

    Potter, G. L.; Bosilovich, M. G.; Dee, D. P.; Compo, G.; Onogi, K.; Saha, S.; Carriere, L.; Nadeau, D.; Williams, D. N.

    2013-12-01

    Reanalysis has become an important tool for use by the atmospheric science community and the data available from the various reanalysis centers is offered in a variety of formats and structure. This variety among the reanalysis efforts makes intercomparison a laborious process. In order to make the data more easily accessible, a new community project called ana4MIPs will be available from the Earth System Grid Federation (ESGF) distributed archive and will include selections from NASA/MERRA, NCEP/CFSR, ECMWF-Interim, NOAA/20CR, and JMA/JRA-25. The data is formatted in a similar way that CMIP5 and will be distributed though ESGF with accompanying technical documents. The data adhere to all the standards used by CMIP5 allowing easy comparison among the various reanalyses and between reanalyses and CMIP5 model output. New analysis packages such as the Ultra-scale Visualization Climate Data Analysis Tools (UV-CDAT) provide an efficient interface to the data and offer a variety of specialized routines for comprehensive analysis and comparison. Access and use of the new interface to reanalysis will be discussed along with examples using the reformatted reanalysis data.

  16. Task 5. Grid interconnection of building integrated and other dispersed photovoltaic power systems. International guideline for the certification of photovoltaic system components and grid-connected systems

    Energy Technology Data Exchange (ETDEWEB)

    Bower, W.

    2002-02-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme presents a guideline for the certification of photovoltaic system components and grid-connected systems. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. This generic international guideline for the certification of photovoltaic system components and complete grid-connected photovoltaic systems describes a set of recommended methods and tests that may be used to verify the integrity of hardware and installations, compliance with applicable standards/codes and can be used to provide a measure of the performance of components or of entire systems. The guideline is to help ensure that photovoltaic installations are both safe for equipment as well as for personnel when used according to the applicable installation standards and codes. The guideline may be used in any country using the rules stipulated by the applicable standards and codes and by applying them to the guideline's recommended tests. This document uses examples for some tests but does not specify exact test set-ups, equipment accuracy, equipment manufacturers or calibration procedures.

  17. Distributed Secondary Control for Islanded MicroGrids – A Networked Control Systems Approach

    DEFF Research Database (Denmark)

    Shafiee, Qobad; Vasquez, Juan Carlos; Guerrero, Josep M.

    2012-01-01

    control system is used in order to implement a distributed secondary control thus avoiding the use of a MicroGrid Central Control. The proposed approach is not only able to restore frequency and voltage of the MicroGrid but also ensures reactive power sharing. The distributed secondary control do......This paper presents a novel approach to conceive the secondary control in droop-controlled MicroGrids. The conventional approach is based on restoring the frequency and amplitude deviations produced by the local droop controllers by using a MicroGrid Central Controller. A distributed networked...

  18. On the Building of a Job Scheduler System for Globus Grid Environment

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Grid system is an emerging infrastructure that promises to unify resources and computing power in many organizations together. At the present state, it is still very complex to use grid system due to the lack of a powerful and highly automated grid resource manager. In this paper,the development of a grid resource manager called SCEGrid is presented. The architecture of global-scope resource management software for grid system is proposed.Then, the design and development of scheduler software are described. SCEGrid software allows users to use simple single-command to submit, query, and cancel existing sequential jobs running in the grid. This eliminates the need to manually write the complicate job descriptions files. The experimental results have been conducted to compare between system with and without SCEGrid using the execution time of arbitrary number of sequential jobs. The experimental results indicate that SCEGrid can speed up the total run time of task sequence on the experimental grid system. In summary, SCEGrid provides a means for users to effectively exploit the huge amount of computing power make available by the grid infrastructure to solve their compute intensive problems.

  19. Smart grid strategy - the future intelligent energy system. [Denmark]; Smart grid-strategi - fremtidens intelligente energisystem

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-04-15

    The Government's Smart Grid Strategy brings Danish consumers a big step closer to managing their own energy consumption. The strategy, combines electricity meters read on an hourly basis with variable tariffs and a data hub. It will make it possible for consumers to use the power when it is least expensive. ''Today we set the course for developing a smart energy network that will reduce the cost of converting to sustainable energy, cut electricity bills and create brand new products consumers will welcome,'' says Minister of Climate, Energy and Building Martin Lidegaard. Encouraging consumers to use energy more efficiently is a key aspect of the strategy. The remote-read electricity meters are crucial if consumers are to play a role in optimising the flexible energy network. (LN)

  20. Analysis of SDFT based phase detection system for grid synchronization of distributed generation systems

    Directory of Open Access Journals (Sweden)

    B. Chitti Babu

    2014-12-01

    Full Text Available A fast and exact detection of phase and fundamental frequency of grid voltage/current is essential for calculating accurate reference signal in order to implement the control algorithm of inverter-interfaced distributed generation (DG system and realize precise harmonic compensation. However, the methods adapted in the literature based on phase locked loop (PLL exhibits large phase error, be difficult to implement, and their performance is also indistinct under conditions where the grid frequency varies or the supply is distorted with low frequency harmonics. This paper explores an improved phase detection system for DG system based on Sliding Discrete Fourier Transform (SDFT. The proposed SDFT based phase detection shows a robust phase tracking capability with fast transient response under adverse situation of the grid. Moreover, SDFT phase detection system is more efficient as it requires small number of operations to extract a single frequency component, thereby reducing computational complexity and simpler than DFT. The superior performance of proposed SDFT phase detection system is analyzed and the obtained results are compared with Discrete Fourier Transform (DFT filtering to confirm the feasibility of the study under different grid environment such as high frequency harmonic injection, frequency deviation, and phase variation etc.

  1. 采用模糊理论的接地网故障诊断方法%Method of Grounding Grid Fault Diagnosis Based on Fuzzy Theory

    Institute of Scientific and Technical Information of China (English)

    张蓬鹤; 何俊佳; 尹小根

    2011-01-01

    In order to settle the problem of the exact fault placement on grounding grid, a new fault diagnosis method was brought forward based on the fuzzy theory. The two important principles of fuzzy theory, degree of nearness and furthest selection, were improved according to this specific problem of grounding grid fault diagnosis. Making use of the complex image method and Prony method, adopting the MATLAB program, the distribution of earth surface potential of the 10xl0 intact and fault grounding grid were calculated, as the sample data-base. Adopting VC++ program, calculating the relation between the intact grounding grid sample and the fault grounding grid sample based on the improved fuzzy degree of nearness, the fault sample data-base were diagnosed. Subsequently, calculating the difference between the fault samples, the fault placement of grounding grid was diagnosed based on the principle of furthest selection. The result indicated that the accuracy is high.%为解决接地网故障准确定位的问题,笔者提出了采用模糊函数的接地网故障诊断方法.根据接地网故障诊断这一具体问题,改进了模糊理论中的两个重要原则--贴近度和择近原则.利用复镜像法和Prony 法,采用MATLAB进行编程,计算出10×10完整状态接地网和故障状态接地网的地表电位分布,作为诊断算法样本数据库.采用VC++编程,用改进的贴近度公式计算完整状态接地网样本与故障状态接地网样本之间的关系,初步诊断出故障样本库.最后,计算故障样本内各点之间的差异值,利用择远原则最终诊断出接地网的故障位置.运算结果表明模糊理论算法准确率高.

  2. A Thermal grid coordinated by a Multi Agent Energy Management System

    NARCIS (Netherlands)

    Pruissen, O.P. van; Kamphuis, V.; Togt, A. van der; Werkman, E.

    2013-01-01

    In the near future an increase of both thermal grids and sustainable suppliers of heat with intermittency behavior, connected to these heat grids, is expected. For smart operation this challenges the current centralized management systems. To deal with this and to optimize cost and energy efficiency

  3. Interaction and Coordination among Nuclear Power Plants, Power Grids and Their Protection Systems

    Directory of Open Access Journals (Sweden)

    Guoyang Wu

    2016-04-01

    Full Text Available Nuclear power plants (NPPs have recently undergone rapid development in China. To improve the performance of both NPPs and grids during adverse conditions, a precise understanding of the coordination between NPPs and grids is required. Therefore, a new mathematical model with reasonable accuracy and reduced computational complexity is developed. This model is applicable to the short, mid, and long-term dynamic simulation of large-scale power systems. The effectiveness of the model is verified by using an actual NPP full-scope simulator as a reference. Based on this model, the interaction and coordination between NPPs and grids under the conditions of over-frequency, under-frequency and under-voltage are analyzed, with special stress applied to the effect of protection systems on the safe operation of both NPPs and power grids. Finally, the coordinated control principles and schemes, together with the recommended protection system values, are proposed for both NPPs and grids. These results show that coordination between the protection systems of NPPs and power networks is a crucial factor in ensuring the safe and stable operation of both NPPs and grids. The results can be used as a reference for coordination between NPPs and grids, as well as for parameter optimization of grid-related generator protection of NPPs.

  4. Optimal Utilization of Microgrids Supplemented with Battery Energy Storage Systems in Grid Support Applications

    DEFF Research Database (Denmark)

    Anvari-Moghaddam, Amjad; Dragicevic, Tomislav; Vasquez, Juan Carlos

    2015-01-01

    This paper proposes a control scheme which minimizes the operating cost of a grid connected micro-grid supplemented by battery energy storage system (BESS). What distinguishes approach presented here from conventional strategies is that not only the price of electricity is considered...

  5. Innovative Distributed Power Grid Interconnection and Control Systems: Final Report, December 11, 2000 - August 30, 2005

    Energy Technology Data Exchange (ETDEWEB)

    DePodesta, K.; Birlingmair, D.; West, R.

    2006-03-01

    The contract goal was to further advance distributed generation in the marketplace by making installations more cost-effective and compatible with existing systems. This was achieved by developing innovative grid interconnection and control systems.

  6. Design of investment management optimization system for power grid companies under new electricity reform

    Science.gov (United States)

    Yang, Chunhui; Su, Zhixiong; Wang, Xin; Liu, Yang; Qi, Yongwei

    2017-03-01

    The new normalization of the economic situation and the implementation of a new round of electric power system reform put forward higher requirements to the daily operation of power grid companies. As an important day-to-day operation of power grid companies, investment management is directly related to the promotion of the company's operating efficiency and management level. In this context, the establishment of power grid company investment management optimization system will help to improve the level of investment management and control the company, which is of great significance for power gird companies to adapt to market environment changing as soon as possible and meet the policy environment requirements. Therefore, the purpose of this paper is to construct the investment management optimization system of power grid companies, which includes investment management system, investment process control system, investment structure optimization system, and investment project evaluation system and investment management information platform support system.

  7. Renaissance architecture for Ground Data Systems

    Science.gov (United States)

    Perkins, Dorothy C.; Zeigenfuss, Lawrence B.

    1994-01-01

    The Mission Operations and Data Systems Directorate (MO&DSD) has embarked on a new approach for developing and operating Ground Data Systems (GDS) for flight mission support. This approach is driven by the goals of minimizing cost and maximizing customer satisfaction. Achievement of these goals is realized through the use of a standard set of capabilities which can be modified to meet specific user needs. This approach, which is called the Renaissance architecture, stresses the engineering of integrated systems, based upon workstation/local area network (LAN)/fileserver technology and reusable hardware and software components called 'building blocks.' These building blocks are integrated with mission specific capabilities to build the GDS for each individual mission. The building block approach is key to the reduction of development costs and schedules. Also, the Renaissance approach allows the integration of GDS functions that were previously provided via separate multi-mission facilities. With the Renaissance architecture, the GDS can be developed by the MO&DSD or all, or part, of the GDS can be operated by the user at their facility. Flexibility in operation configuration allows both selection of a cost-effective operations approach and the capability for customizing operations to user needs. Thus the focus of the MO&DSD is shifted from operating systems that we have built to building systems and, optionally, operations as separate services. Renaissance is actually a continuous process. Both the building blocks and the system architecture will evolve as user needs and technology change. Providing GDS on a per user basis enables this continuous refinement of the development process and product and allows the MO&DSD to remain a customer-focused organization. This paper will present the activities and results of the MO&DSD initial efforts toward the establishment of the Renaissance approach for the development of GDS, with a particular focus on both the technical

  8. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [ENVIRON; Yavuzturk, Cy [University of Hartford; Pinder, George [University of Vermont

    2015-04-15

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  9. Optimal Ground Source Heat Pump System Design

    Energy Technology Data Exchange (ETDEWEB)

    Ozbek, Metin [Environ Holdings Inc., Princeton, NJ (United States); Yavuzturk, Cy [Univ. of Hartford, West Hartford, CT (United States); Pinder, George [Univ. of Vermont, Burlington, VT (United States)

    2015-04-01

    Despite the facts that GSHPs first gained popularity as early as the 1940’s and they can achieve 30 to 60 percent in energy savings and carbon emission reductions relative to conventional HVAC systems, the use of geothermal energy in the U.S. has been less than 1 percent of the total energy consumption. The key barriers preventing this technically-mature technology from reaching its full commercial potential have been its high installation cost and limited consumer knowledge and trust in GSHP systems to deliver the technology in a cost-effective manner in the market place. Led by ENVIRON, with support from University Hartford and University of Vermont, the team developed and tested a software-based a decision making tool (‘OptGSHP’) for the least-cost design of ground-source heat pump (‘GSHP’) systems. OptGSHP combines state of the art optimization algorithms with GSHP-specific HVAC and groundwater flow and heat transport simulation. The particular strength of OptGSHP is in integrating heat transport due to groundwater flow into the design, which most of the GSHP designs do not get credit for and therefore are overdesigned.

  10. Analysis on Design of Grid-connected PV System%并网光伏系统设计简析

    Institute of Scientific and Technical Information of China (English)

    罗刚; 俞晟

    2014-01-01

    简要介绍常见并网光伏系统设计依据、常用软件、组成部分及其原理,以及光设计中需要把握的原则、注意事项和一些经验教训,包括光伏支架、光伏方阵与场地的设计考虑,并网逆变器的选择、并网形式的选择、防雷接地等。%The paper provides a brief introduction of the design basis, common software, components and principles of common grid-connected PV system, as well as principles, considerations and some experiences in PV design, including the design considerations of PV stent, PV array and venue, selection of grid-connected inverter and form and grounding for protection against lightning.

  11. Performance of Grid-Connected Photovoltaic System in Two Sites in Kuwait

    OpenAIRE

    2012-01-01

    This paper presents an assessment of the electricity generated by photovoltaic (PV) grid-connected systems in Kuwait. Three years of meteorological data are provided for two main sites in Kuwait, namely, Al-Wafra and Mutla. These data and a PV grid-connected system mathematical model are used to assist a 100 kWp grid-connected PV system proposed for both sites. The proposed systems show high energy productivity whereas the annual capacity factors for Mutla and Al-Wafra are 22.25% and 21.6%, r...

  12. Monitoring the Earth System Grid Federation through the ESGF Dashboard

    Science.gov (United States)

    Fiore, S.; Bell, G. M.; Drach, B.; Williams, D.; Aloisio, G.

    2012-12-01

    The Climate Model Intercomparison Project, phase 5 (CMIP5) is a global effort coordinated by the World Climate Research Programme (WCRP) involving tens of modeling groups spanning 19 countries. It is expected the CMIP5 distributed data archive will total upwards of 3.5 petabytes, stored across several ESGF Nodes on four continents (North America, Europe, Asia, and Australia). The Earth System Grid Federation (ESGF) provides the IT infrastructure to support the CMIP5. In this regard, the monitoring of the distributed ESGF infrastructure represents a crucial part carried out by the ESGF Dashboard. The ESGF Dashboard is a software component of the ESGF stack, responsible for collecting key information about the status of the federation in terms of: 1) Network topology (peer-groups composition), 2) Node type (host/services mapping), 3) Registered users (including their Identity Providers), 4) System metrics (e.g., round-trip time, service availability, CPU, memory, disk, processes, etc.), 5) Download metrics (both at the Node and federation level). The last class of information is very important since it provides a strong insight of the CMIP5 experiment: the data usage statistics. In this regard, CMCC and LLNL have developed a data analytics management system for the analysis of both node-level and federation-level data usage statistics. It provides data usage statistics aggregated by project, model, experiment, variable, realm, peer node, time, ensemble, datasetname (including version), etc. The back-end of the system is able to infer the data usage information of the entire federation, by carrying out: - at node level: a 18-step reconciliation process on the peer node databases (i.e. node manager and publisher DB) which provides a 15-dimension datawarehouse with local statistics and - at global level: an aggregation process which federates the data usage statistics into a 16-dimension datawarehouse with federation-level data usage statistics. The front-end of the

  13. Wireless Sensor Network Based Smart Grid Communications: Cyber Attacks, Intrusion Detection System and Topology Control

    Directory of Open Access Journals (Sweden)

    Lipi Chhaya

    2017-01-01

    Full Text Available The existing power grid is going through a massive transformation. Smart grid technology is a radical approach for improvisation in prevailing power grid. Integration of electrical and communication infrastructure is inevitable for the deployment of Smart grid network. Smart grid technology is characterized by full duplex communication, automatic metering infrastructure, renewable energy integration, distribution automation and complete monitoring and control of entire power grid. Wireless sensor networks (WSNs are small micro electrical mechanical systems that are deployed to collect and communicate the data from surroundings. WSNs can be used for monitoring and control of smart grid assets. Security of wireless sensor based communication network is a major concern for researchers and developers. The limited processing capabilities of wireless sensor networks make them more vulnerable to cyber-attacks. The countermeasures against cyber-attacks must be less complex with an ability to offer confidentiality, data readiness and integrity. The address oriented design and development approach for usual communication network requires a paradigm shift to design data oriented WSN architecture. WSN security is an inevitable part of smart grid cyber security. This paper is expected to serve as a comprehensive assessment and analysis of communication standards, cyber security issues and solutions for WSN based smart grid infrastructure.

  14. The capacity credit of grid-connected photovoltaic systems

    Science.gov (United States)

    Alsema, E. A.; van Wijk, A. J. M.; Turkenburg, W. C.

    The capacity credit due photovoltaic (PV) power plants if integrated into the Netherlands grid was investigated, together with an estimate of the total allowable penetration. An hourly simulation was performed based on meteorological data from five stations and considering tilted surfaces, the current grid load pattern, and the load pattern after PV-power augmentation. The reliability of the grid was assessed in terms of a loss of load probability analysis, assuming power drops were limited to 1 GW. A projected tolerance for 2.5 GW of PV power was calculated. Peak demands were determined to be highest in winter, contrary to highest insolation levels; however, daily insolation levels coincided with daily peak demands. Combining the PV input with an equal amount of wind turbine power production was found to augment the capacity credit for both at aggregate outputs of 2-4 GW.

  15. The Effect Of Numbers Of Inverters In Photovoltaic Grid Connected System On Efficiency Reliability And Cost

    Directory of Open Access Journals (Sweden)

    Aliaa N.Madkor

    2015-08-01

    Full Text Available Abstract The DCAC inverters are used in grid-connected PV energy production systems as the power processing interface between the PV energy source and the electric grid. The energy injected into the electric grid by the PV installation depends on the amount of power extracted from the PV power source and the efficient processing of this power by the DCAC inverter. The main target of this paper is to determine the principle that achieves high reliability and efficiency with the low cost of the photovoltaic grid-connected system. Accordingly we are considering the inverter as it represents the important part of the system by a comparison among the following three systems The system has one inverter with the power of 100 kw The system has two inverters each has the power of 50 kw and The system has twenty inverters each has the power of 5 kW. We will check the effect of number of inverters in photovoltaic grid-connected system on efficiency reliability and cost taking into account the fixed system one axis tracking system and two axes tracking system. Also in order to validate the accuracy of the proposed control strategy grid-connected PV system is simulated based on MATLABSimulink.

  16. The smart grid adapting the power system to new challenges

    CERN Document Server

    Bollen, Math

    2011-01-01

    This book links the challenges to which the electricity network is exposed with the range of new technology, methodologies and market mechanisms known under the name ""smart grid."" The main challenges will be described by the way in which they impact the electricity network: the introduction of renewable electricity production, energy efficiency, the introduction and further opening of the electricity market, increasing demands for reliability and voltage quality, and the growing need for more transport capacity in the grid. Three fundamentally different types of solutions are distinguished i

  17. Multi-agent approach for power system in a smart grid protection context

    DEFF Research Database (Denmark)

    Abedini, Reza; Pinto, Tiago; Morais, Hugo

    2013-01-01

    proposes a new approach for protection in a Microgrid environment as a part of SmartGrid: Multi-agent system to Protections Coordination (MAS-ProteC) which integrated in MASGriP (Multi-Agent Smart Grid Platform), providing protection services within network operation in SmartGrid in electricity market...... electricity markets and in the other hand with increasing penetration of Distributed Generation (DG) because of environment issues and diminishing in fossil fuel reserves and its price growth, made microgrid more attractive. Micro grids are considers as partial of SmartGrid system to accommodate DGs as well......With increasing penetration of electricity application in society and the need of majority of appliance to electricity, high level of reliability becomes more essential; in one hand with deregulation of electricity market in production, transmission and distribution and emerge of competitive...

  18. Performance of R-GMA based grid job monitoring system for CMS data production

    CERN Document Server

    Byrom, Robert; Fisher, Steve M; Grandi, Claudio; Hobson, Peter R; Kyberd, Paul; MacEvoy, Barry; Nebrensky, Jindrich Josef; Tallini, Hugh; Traylen, Stephen

    2004-01-01

    High Energy Physics experiments, such as the Compact Muon Solenoid (CMS) at the CERN laboratory in Geneva, have large-scale data processing requirements, with stored data accumulating at a rate of 1 Gbyte/s. This load comfortably exceeds any previous processing requirements and we believe it may be most efficiently satisfied through Grid computing. Management of large Monte Carlo productions (~3000 jobs) or data analyses and the quality assurance of the results requires careful monitoring and bookkeeping, and an important requirement when using the Grid is the ability to monitor transparently the large number of jobs that are being executed simultaneously at multiple remote sites. R-GMA is a monitoring and information management service for distributed resources based on the Grid Monitoring Architecture of the Global Grid Forum. We have previously developed a system allowing us to test its performance under a heavy load while using few real Grid resources. We present the latest results on this system and comp...

  19. Joint Polar Satellite System Common Ground System Overview

    Science.gov (United States)

    Jamilkowski, M. L.; Smith, D. C.

    2011-12-01

    Jointly acquired by NOAA & NASA, the next-generation civilian environmental satellite system, Joint Polar Satellite System (JPSS), will supply the afternoon orbit & ground system of the restructured NPOESS program. JPSS will replace NOAA's current POES satellites and the ground processing part of both POES & DoD's Defense Weather Satellite System (DWSS)(DMSP replacement). JPSS sensors will collect meteorological, oceanographic, climatological and solar-geophysical data. The ground system, or JPSS Common Ground System (CGS), has 6 integrated product teams/segments: Command, Control & Communications (C3S); Interface Data Processing (IDPS); Field Terminal (FTS); Systems Engineering, Integration & Test (SEIT); Operations & Support (O&S); and Sustainment developed by Raytheon Intelligence & Information Systems. The IDPS will process JPSS data to provide Environmental Data Records (EDRs) to NOAA & DoD processing centers beginning with the NPOESS Preparatory Project (NPP) and through JPSS & DWSS eras. C3S will: manage overall JPSS & DWSS missions from control/status of space/ground assets to ensure timely delivery of high-quality data to IDPS; provide globally-distributed ground assets to collect/transport mission, telemetry and command data between satellites & processing locations; provide all commanding & state-of-health monitoring functions of NPP, JPSS and DWSS satellites, and delivery of mission data to each Central IDP and monitor/report system-wide health/status and data communications with external systems and between CGS segments. SEIT leads the overall effort, including: manage/coordinate/execute JPSS CGS activities with NASA participation/oversight; plan/conduct all activities related to systems engineering, develop & ensure completeness of JPSS CGS functional & technical baselines and perform integration, deployment, testing and verification; sponsor/support modeling & simulation, performance analysis and trade studies; provide engineering for the product

  20. Research and design of smart grid monitoring control via terminal based on iOS system

    Science.gov (United States)

    Fu, Wei; Gong, Li; Chen, Heli; Pan, Guangji

    2017-06-01

    Aiming at a series of problems existing in current smart grid monitoring Control Terminal, such as high costs, poor portability, simple monitoring system, poor software extensions, low system reliability when transmitting information, single man-machine interface, poor security, etc., smart grid remote monitoring system based on the iOS system has been designed. The system interacts with smart grid server so that it can acquire grid data through WiFi/3G/4G networks, and monitor each grid line running status, as well as power plant equipment operating conditions. When it occurs an exception in the power plant, incident information can be sent to the user iOS terminal equipment timely, which will provide troubleshooting information to help the grid staff to make the right decisions in a timely manner, to avoid further accidents. Field tests have shown the system realizes the integrated grid monitoring functions, low maintenance cost, friendly interface, high security and reliability, and it possesses certain applicable value.

  1. 40 CFR 258.51 - Ground-water monitoring systems.

    Science.gov (United States)

    2010-07-01

    ... preclude installation of ground-water monitoring wells at the relevant point of compliance at existing... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Ground-water monitoring systems. 258... CRITERIA FOR MUNICIPAL SOLID WASTE LANDFILLS Ground-Water Monitoring and Corrective Action § 258.51...

  2. Agent-based Decentralization of Applications in Distributed Smart Grid Systems

    DEFF Research Database (Denmark)

    Kienesberger, Georg; Xypolytou, Evangelia; Marchgraber, Jurgen

    2015-01-01

    dezentralized concepts in order to adapt to the distributed nature of smart grids. Multi-agent systems (MAS) are a very promising approach for designing distributed, decentralized systems, naturally also in the field of smart grids. This work introduces the notion of decentralized multi-agent-based control......Smart grid technology promises to prepare today’s power systems for the challenges of the future by extensive integration of information and communication technology (ICT). One key aspect is the control paradigm which will have to be shifted from completely centralized control systems to more...... systems (DMACS) and aims to give an overview on the different requirements and challenges on the way from current centralized control systems to DMACS. Therefore, different ICT scenarios and MAS topologies are employed to discuss the decentralization of three exemplary smart grid applications: voltage...

  3. Simulation of offshore wind farm integrated into power grid using VSC HVDC system

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Hui; Nguyen, Mau Cuong; Rudion, Krzystof; Styczynski, Zbigniew Antoni [Magdeburg Univ. (Germany). Chair for Electric Power Networks and Renewable Energy Sources

    2011-07-01

    In this paper, the integration of an offshore wind farm into a power grid is studied based on the simulation of a developed test system including an aggregated DFIG wind farm model and VSC HVDC transmission system model. This paper concentrates on the transient stability and system performance with an applied controller for DFIG and HVDC converter stations. The results are obtained by simulation of the test system subjected to severe grid disturbance, e.g. three-phase short circuit fault at the point of common coupling (PCC). Furthermore, the conformity of the system performance with the current grid code, e.g. fault-ride through capability is investigated and confirmed from the simulation results. In addition, a DC-chopper circuit is modeled to protect the HVDC-link from the overvoltage without disconnection during grid faults. Different time delays of the DC-chopper are considered and simulated to investigate its influence on the system dynamics and performance. (orig.)

  4. Impedance-Based High Frequency Resonance Analysis of DFIG System in Weak Grids

    DEFF Research Database (Denmark)

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    The impedance-based model of Doubly Fed Induction Generator (DFIG) systems, including the rotor part (Rotor Side Converter (RSC) and induction machine), and the grid part (Grid Side Converter (GSC) and its output filter), has been developed for analysis and mitigation of the Sub- Synchronous...... Resonance (SSR). However, the High Frequency Resonance (HFR) of DFIG systems due to the impedance interaction between DFIG system and parallel compensated weak network is often overlooked. This paper thus investigates the impedance characteristics of DFIG systems for the analysis of HFR. The influences...... of the rotor speed variation, the machine mutual inductance and the digital control delay are evaluated. Two resonances phenomena are revealed, i.e., 1) the series HFR between the DFIG system and weak power grid; 2) the parallel HFR between the rotor part and the grid part of DFIG system. The impedance...

  5. Agent-based Decentralization of Applications in Distributed Smart Grid Systems

    DEFF Research Database (Denmark)

    Kienesberger, Georg; Xypolytou, Evangelia; Marchgraber, Jurgen

    2015-01-01

    Smart grid technology promises to prepare today’s power systems for the challenges of the future by extensive integration of information and communication technology (ICT). One key aspect is the control paradigm which will have to be shifted from completely centralized control systems to more...... dezentralized concepts in order to adapt to the distributed nature of smart grids. Multi-agent systems (MAS) are a very promising approach for designing distributed, decentralized systems, naturally also in the field of smart grids. This work introduces the notion of decentralized multi-agent-based control...... systems (DMACS) and aims to give an overview on the different requirements and challenges on the way from current centralized control systems to DMACS. Therefore, different ICT scenarios and MAS topologies are employed to discuss the decentralization of three exemplary smart grid applications: voltage...

  6. The Earth System Grid Center for Enabling Technologies (ESG-CET): Scaling the Earth System Grid to Petascale Data

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Dean N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2007-09-27

    This report, which summarizes work carried out by the ESG-CET during the period April 1, 2007 through September 30, 2007, includes discussion of overall progress, period goals, highlights, collaborations and presentations. To learn more about our project, please visit the Earth System Grid website. In addition, this report will be forwarded to the DOE SciDAC project management, the Office of Biological and Environmental Research (OBER) project management, national and international stakeholders (e.g., the Community Climate System Model (CCSM), the Intergovernmental Panel on Climate Change (IPCC) 5th Assessment Report (AR5), the Climate Science Computational End Station (CCES), etc.), and collaborators. The ESG-CET executive committee consists of David Bernholdt, ORNL; Ian Foster, ANL; Don Middleton, NCAR; and Dean Williams, LLNL. The ESG-CET team is a collective of researchers and scientists with diverse domain knowledge, whose home institutions include seven laboratories (ANL, LANL, LBNL, LLNL, NCAR, ORNL, PMEL) and one university (ISI/USC); all work in close collaboration with the project's stakeholders and domain researchers and scientists. During this semi-annual reporting period, the ESG-CET increased its efforts on completing requirement documents, framework design, and component prototyping. As we strove to complete and expand the overall ESG-CET architectural plans and use-case scenarios to fit our constituency's scope of use, we continued to provide production-level services to the community. These services continued for IPCC AR4, CCES, and CCSM, and were extended to include Cloud Feedback Model Intercomparison Project (CFMIP) data.

  7. Suggested Grid Code Modifications to Ensure Wide-Scale Adoption of Photovoltaic Energy in Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Enjeti, Prasad; Blaabjerg, Frede;

    2013-01-01

    -phase PV systems in the distributed grid, the disconnection under grid faults can contribute to: a) voltage flickers, b) power outages, and c) system instability. In this paper, grid code modifications are explored for wide-scale adoption of PV systems in the distribution grid. More recently, Italy......Current grid standards seem to largely require low power (e.g. several kilowatts) single-phase photovoltaic (PV) systems to operate at unity power factor with maximum power point tracking, and disconnect from the grid under grid faults. However, in case of a wide-scale penetration of single...... and Japan, have undertaken a major review of standards for PV power conversion systems connected to low voltage networks. In view of this, the importance of low voltage ride-through for single-phase PV power systems under grid faults along with reactive power injection is studied in this paper. Three...

  8. Development and Testing of a Prototype Grid-Tied Photovoltaic Power System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2009-01-01

    The NASA Glenn Research Center (GRC) has developed and tested a prototype 2 kW DC grid-tied photovoltaic (PV) power system at the Center. The PV system has generated in excess of 6700 kWh since operation commenced in July 2006. The PV system is providing power to the GRC grid for use by all. Operation of the prototype PV system has been completely trouble free. A grid-tied PV power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. The project transfers space technology to terrestrial use via nontraditional partners. GRC personnel glean valuable experience with PV power systems that are directly applicable to various space power systems, and provide valuable space program test data. PV power systems help to reduce harmful emissions and reduce the Nation s dependence on fossil fuels. Power generated by the PV system reduces the GRC utility demand, and the surplus power aids the community. Present global energy concerns reinforce the need for the development of alternative energy systems. Modern PV panels are readily available, reliable, efficient, and economical with a life expectancy of at least 25 years. Modern electronics has been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy of at least 25 years. Based upon the success of the prototype PV system, additional PV power system expansion at GRC is under consideration. The prototype grid-tied PV power system was successfully designed and developed which served to validate the basic principles described, and the theoretical work that was performed. The report concludes that grid-tied photovoltaic power systems are reliable, maintenance free, long life power systems, and are of significant value to NASA and the community.

  9. Impedance-Based High Frequency Resonance Analysis of DFIG System in Weak Grids

    OpenAIRE

    Song, Yipeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    The impedance-based model of Doubly Fed Induction Generator (DFIG) systems, including the rotor part (Rotor Side Converter (RSC) and induction machine), and the grid part (Grid Side Converter (GSC) and its output filter), has been developed for analysis and mitigation of the Sub- Synchronous Resonance (SSR). However, the High Frequency Resonance (HFR) of DFIG systems due to the impedance interaction between DFIG system and parallel compensated weak network is often overlooked. This paper thus...

  10. Integration of Vehicle-to-Grid in Western Danish Power System

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2011-01-01

    capabilities of large power plants in the future, demands for new balancing solutions like Vehicle-to-Grid systems. In this article, aggregated electric vehicle based battery storage representing a Vehicle-to-Grid system is modelled for the use in long term dynamic power system simulations. Further...... Transmission) control areas are significantly minimized by the faster up and down regulation characteristics of the electric vehicle battery storage....

  11. Modeling and Control for Smart Grid Integration\\ud of Solar/Wind Energy Conversion System

    OpenAIRE

    2011-01-01

    Performance optimization, system reliability and operational efficiency are key characteristics of smart grid systems. In this paper a novel model of smart grid-connected PV/WT hybrid system is developed. It comprises photovoltaic array, wind turbine, asynchronous (induction) generator, controller and converters. The model is implemented using MATLAB/SIMULINK software package. Perturb and observe (P&O) algorithm is used for maximizing the generated power based on maximum power point tracker (...

  12. Future evolution of distributed systems for smart grid - The challenges and opportunities to using decentralized energy system

    Science.gov (United States)

    Konopko, Joanna

    2015-12-01

    A decentralized energy system is a relatively new approach in the power industry. Decentralized energy systems provide promising opportunities for deploying renewable energy sources locally available as well as for expanding access to clean energy services to remote communities. The electricity system of the future must produce and distribute electricity that is reliable and affordable. To accomplish these goals, both the electricity grid and the existing regulatory system must be smarter. In this paper, the major issues and challenges in distributed systems for smart grid are discussed and future trends are presented. The smart grid technologies and distributed generation systems are explored. A general overview of the comparison of the traditional grid and smart grid is also included.

  13. Harmonics Suppression for Single-Phase Grid-Connected Photovoltaic Systems in Different Operation Modes

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2013-01-01

    As the penetration of grid-connected photovoltaic (PV) systems is booming, specific grid demands are imposed on such interconnected PV systems. Therefore, achieving high reliable PV systems with high power quality is of intense interest. However, the injected current from single-phase grid-connected......-phase grid-connected PV systems in different operation modes. Especially, it can remove higher order harmonics effectively leading to a better power quality compared to the Proportional plus Multi-Resonant Controller, and it has less computational burden....... PV inverters may be severely affected in different operation modes. In this paper, a detailed analysis is conducted to reveal the relationship between the harmonics level with the power factor and the current level in the PV systems. A current control solution which employs an Internal Model...

  14. Evaluation of Energy Storage System to Support Danish Island of Bornholm Power Grid

    DEFF Research Database (Denmark)

    Cha, Seung-Tae; Zhao, Haoran; Wu, Qiuwei

    2012-01-01

    This paper presents a real-time evaluation and simulation approach of energy storage system (ESS) based on large renewable-based electricity generation, which can be used for grid support. The ESS is designed to maintain power quality as a primary regulation, while the conventional generation units...... handle the secondary frequency regulation to mitigate ramping issues. The real time models of Bornholm distribution grid, which is the combination of an aggregated wind power generation and the energy storage system (ESS) has been used to test the system and control approach in a real time grid simulator...... to identify the improvement of the grid support capability. The interactive simulation platform with real-time energy forecasting data running online with a link to the Bornholm power system data are being used to measure and validate the system performance with and without energy storage after a disturbance....

  15. Optimal DG Source Allocation for Grid Connected Distributed Generation with Energy Storage System

    Directory of Open Access Journals (Sweden)

    S. Ezhilarasan

    2015-05-01

    Full Text Available This study proposes an Energy Management System (EMS for allocation of DG source in a grid connected hybrid power system. Modeling and simulation for EMS is implemented using MATLAB/SIMULINK package. The objective of proposed EMS for micro grid is to optimize the fuel cost, improving the energy utilization efficiency and to manage the peak load demand by scheduling the generation according to the availability of the fuel. The proposed intelligent energy management system is designed to optimize the availability of energy to the load according to the level of priority and to manage the power flow. The developed management system performance was assessed using a hybrid system having PV panels, Wind Turbine (WT, battery and biomass gasifier. Real time field test has been conducted and the parameters i.e., solar irradiance, temperature, wind speed are gathered from 4.05 KW off grid and 2.0 KW On grid Solar Photovoltaic systems (SPV system and wind turbine. The dynamic behavior of the proposed model is examined under different operating conditions. The simulation results of proposed EMS using fuzzy logic expert system shows the minimization on the operating cost and emission level of micro grid by optimal scheduling of power generation and maintains the State of Charge (SOC of batteries in desired value which improves the battery life. The proposed multi objective intelligent energy management system aims to minimize the operational cost and the environmental impact of a micro grid.

  16. GRID2D/3D: A computer program for generating grid systems in complex-shaped two- and three-dimensional spatial domains. Part 2: User's manual and program listing

    Science.gov (United States)

    Bailey, R. T.; Shih, T. I.-P.; Nguyen, H. L.; Roelke, R. J.

    1990-01-01

    An efficient computer program, called GRID2D/3D, was developed to generate single and composite grid systems within geometrically complex two- and three-dimensional (2- and 3-D) spatial domains that can deform with time. GRID2D/3D generates single grid systems by using algebraic grid generation methods based on transfinite interpolation in which the distribution of grid points within the spatial domain is controlled by stretching functions. All single grid systems generated by GRID2D/3D can have grid lines that are continuous and differentiable everywhere up to the second-order. Also, grid lines can intersect boundaries of the spatial domain orthogonally. GRID2D/3D generates composite grid systems by patching together two or more single grid systems. The patching can be discontinuous or continuous. For continuous composite grid systems, the grid lines are continuous and differentiable everywhere up to the second-order except at interfaces where different single grid systems meet. At interfaces where different single grid systems meet, the grid lines are only differentiable up to the first-order. For 2-D spatial domains, the boundary curves are described by using either cubic or tension spline interpolation. For 3-D spatial domains, the boundary surfaces are described by using either linear Coon's interpolation, bi-hyperbolic spline interpolation, or a new technique referred to as 3-D bi-directional Hermite interpolation. Since grid systems generated by algebraic methods can have grid lines that overlap one another, GRID2D/3D contains a graphics package for evaluating the grid systems generated. With the graphics package, the user can generate grid systems in an interactive manner with the grid generation part of GRID2D/3D. GRID2D/3D is written in FORTRAN 77 and can be run on any IBM PC, XT, or AT compatible computer. In order to use GRID2D/3D on workstations or mainframe computers, some minor modifications must be made in the graphics part of the program; no

  17. Development of Smart Grid for Community and Cyber based Landslide Hazard Monitoring and Early Warning System

    Science.gov (United States)

    Karnawati, D.; Wilopo, W.; Fathani, T. F.; Fukuoka, H.; Andayani, B.

    2012-12-01

    A Smart Grid is a cyber-based tool to facilitate a network of sensors for monitoring and communicating the landslide hazard and providing the early warning. The sensor is designed as an electronic sensor installed in the existing monitoring and early warning instruments, and also as the human sensors which comprise selected committed-people at the local community, such as the local surveyor, local observer, member of the local task force for disaster risk reduction, and any person at the local community who has been registered to dedicate their commitments for sending reports related to the landslide symptoms observed at their living environment. This tool is designed to be capable to receive up to thousands of reports/information at the same time through the electronic sensors, text message (mobile phone), the on-line participatory web as well as various social media such as Twitter and Face book. The information that should be recorded/ reported by the sensors is related to the parameters of landslide symptoms, for example the progress of cracks occurrence, ground subsidence or ground deformation. Within 10 minutes, this tool will be able to automatically elaborate and analyse the reported symptoms to predict the landslide hazard and risk levels. The predicted level of hazard/ risk can be sent back to the network of electronic and human sensors as the early warning information. The key parameters indicating the symptoms of landslide hazard were recorded/ monitored by the electrical and the human sensors. Those parameters were identified based on the investigation on geological and geotechnical conditions, supported with the laboratory analysis. The cause and triggering mechanism of landslide in the study area was also analysed in order to define the critical condition to launch the early warning. However, not only the technical but also social system were developed to raise community awareness and commitments to serve the mission as the human sensors, which will

  18. A grid-enabled MPI : message passing in heterogeneous distributed computing systems.

    Energy Technology Data Exchange (ETDEWEB)

    Foster, I.; Karonis, N. T.

    2000-11-30

    Application development for high-performance distributed computing systems, or computational grids as they are sometimes called, requires grid-enabled tools that hide mundate aspects of the heterogeneous grid environment without compromising performance. As part of an investigation of these issues, they have developed MPICH-G, a grid-enabled implementation of the Message Passing Interface (MPI) that allows a user to run MPI programs across multiple computers at different sites using the same commands that would be used on a parallel computer. This library extends the Argonne MPICH implementation of MPI to use services provided by the globus grid toolkit. In this paper, they describe the MPICH-G implementation and present preliminary performance results.

  19. ARMS: An Agent-Based Resource Management System for Grid Computing

    Directory of Open Access Journals (Sweden)

    Junwei Cao

    2002-01-01

    Full Text Available Resource management is an important component of a grid computing infrastructure. The scalability and adaptability of such systems are two key challenges that must be addressed. In this work an agent-based resource management system, ARMS, is implemented for grid computing. ARMS utilises the performance prediction techniques of the PACE toolkit to provide quantitative data regarding the performance of complex applications running on a local grid resource. At the meta-level, a hierarchy of homogeneous agents are used to provide a scalable and adaptable abstraction of the system architecture. Each agent is able to cooperate with other agents and thereby provide service advertisement and discovery for the scheduling of applications that need to utilise grid resources. A case study with corresponding experimental results is included to demonstrate the efficiency of the resource management and scheduling system.

  20. Improved Control Strategy for DFIG-based Wind Energy Conversion System during Grid Voltage Disturbances

    DEFF Research Database (Denmark)

    Zhu, Rongwu

    simplifies the control system and also reduce the effects of the PLL on system performance. Based on the simulation and experimental results, it clearly verifies that the proposed strategy can accurately control the stator phase angle and completely decouple the stator active and reactive power. Besides...... isolating the stator from the grid, the DFIG voltage can be compensated by the DVR. However, the configuration generally requires large capacity of the DVR system, which will increases the system cost. Therefore, an improved control strategy for the DVR-based DFIG WECS to reduce the capacity of the DVR......For the DFIG-based WECS, due to the direct connection between the stator and grid, the DFIG is sensitive to grid voltage disturbances. The effects from the power grid may produce the oscillations of the stator active and reactive power, oscillatory electromagnetic torque, and distorted stator...

  1. Research on a New Control Scheme of Photovoltaic Grid Power Generation System

    Directory of Open Access Journals (Sweden)

    Dong-Hui Li

    2014-01-01

    Full Text Available A new type of photovoltaic grid power generation system control scheme to solve the problems of the conventional photovoltaic grid power generation systems is presented. To aim at the oscillation and misjudgment of traditional perturbation observation method, an improved perturbation observation method comparing to the next moment power is proposed, combining with BOOST step-up circuit to realize the maximum power tracking. To counter the harmonic pollution problem in photovoltaic grid power generation system, the deadbeat control scheme in fundamental wave synchronous frequency rotating coordinate system of power grid is presented. A parameter optimization scheme based on positive feedback of active frequency shift island detection to solve the problems like the nondetection zone due to the import of disturbance in traditional island detection method is proposed. Finally, the results in simulation environment by MATLAB/Simulink simulation and experiment environment verify the validity and superiority of the proposed scheme.

  2. Versioning for CMIP6 in the Earth System Grid Federation

    Science.gov (United States)

    Weigel, Tobias; Kindermann, Stephan; Lautenschlager, Michael

    2015-04-01

    The Earth System Grid Federation (ESGF) has been used as the e-infrastructure to provide access to CMIP5 data and is expected to serve CMIP6 data as well. 2015 marks the year of continued planning and preparation where new concepts can still be implemented for the operational phase of CMIP6. A particular concern within ESGF operations is the versioning and automated replication of data. From CMIP5 experience we know that the pathway between initial submission of modelling data to the ESGF data space and quality-controlled long-term archival of the final products is long and far from linear. Data may be retracted, amended and updated, and metadata may accumulate at different stages. It is unrealistic to assume that a simple and straightforward process can be used as a role model to build ESGF services around the different stages data will pass through during the active phase of CMIP6. Nonetheless, at the technical level ESGF requires some form of automated control and management. At the same time, the accountability of data products must be made transparent to guard against misinterpretation, increase user experience and promote open and reproducible science. To address the challenges, first some essential versioning policies must be agreed upon and enforced through technical means and organizational processes. The volatile readiness state of CMIP data cannot be changed as it is given by the users; however its management can be improved. A promising approach is to embed persistent identifiers in all CMIP6 data objects and register them so they can be globally resolved by any user and used as reference points within ESGF management processes. A specific conceptual interpretation and management of such identifiers can ensure that they remain valid and useful even if the data objects change or become unavailable. For this, identifiers must be assigned to individual versions and aggregations, connected with each other and integrated in the existing ESGF publication

  3. The research of the malfunction diagnosis and predictions system in the smart electric grid

    Science.gov (United States)

    Wang, Yaqing; Zhang, Guoxing; Xu, Hongbing

    2017-03-01

    The Chinese smart electric grid constriction has been increasing with the technology development. However, the monitoring equipment and background system which should play important roles did not work as intended and restrict to the efficacy of the smart grid. In this essay, it has researched an intelligentized malfunction diagnosis and predictions system which could work with the existed monitoring equipment to function as whole energy monitoring, common malfunction diagnosis, faulted proactive judgment and automatically elimination.

  4. Symmetry without symmetry: Numerical simulation of axisymmetric systems using Cartesian grids.

    OpenAIRE

    Alcubierre, M.; Brandt, S; Brügmann, B.; Holz, D.; Seidel, E; Takahashi, R.; Thornburg, J.

    2001-01-01

    We present a new technique for the numerical simulation of axisymmetric systems. This technique avoids the coordinate singularities which often arise when cylindrical or polar-spherical coordinate finite difference grids are used, particularly in simulating tenser partial differential equations like those of 3 + 1 numerical relativity. For a system axisymmetric about the r axis, the basic idea is to use a three-dimensional Cartesian (x,y,z) coordinate grid which covers (say) the y = 0 plane, ...

  5. Maximum Power Point Tracking and Reactive Power Control of Single Stage Grid Connected Photovoltaic System

    OpenAIRE

    2011-01-01

    Single-stage grid-connected Photovoltaic (PV) systems have advantages such as simple topology, high efficiency, etc. However, since all the control objectives such as the maximum power point tracking (with the utility voltage, and harmonics reduction for output current need to be considered simultaneously, the complexity of the control scheme is much increased. In this paper a new type of grid connected photovoltaic (PV) system with Maximum Power Point Tracking (MPPT) and reactive power simul...

  6. Shunt Connected STATCOM Control Grid of Wind Turbine System for Balanced and Unbalanced Non Linear Loads

    OpenAIRE

    Vinay Kumar. Polishetty; Dr.S.Siva Prasad

    2014-01-01

    Injection of wind power into the grid affects the power quality resulting in poor performance of the system. The power arising out of the wind turbine when connected to a grid system concerning the power quality measurements are active power, reactive power, voltage sag, voltage sell, flicker, harmonics, and electrical behavior of switching operation. This paper proposes a control scheme based on instantaneous reactive power theory for compensating reactive power requirements ...

  7. Assembling Large, Multi-Sensor Climate Datasets Using the SciFlo Grid Workflow System

    Science.gov (United States)

    Wilson, B.; Manipon, G.; Xing, Z.; Fetzer, E.

    2009-04-01

    NASA's Earth Observing System (EOS) is an ambitious facility for studying global climate change. The mandate now is to combine measurements from the instruments on the "A-Train" platforms (AIRS, AMSR-E, MODIS, MISR, MLS, and CloudSat) and other Earth probes to enable large-scale studies of climate change over periods of years to decades. However, moving from predominantly single-instrument studies to a multi-sensor, measurement-based model for long-duration analysis of important climate variables presents serious challenges for large-scale data mining and data fusion. For example, one might want to compare temperature and water vapor retrievals from one instrument (AIRS) to another instrument (MODIS), and to a model (ECMWF), stratify the comparisons using a classification of the "cloud scenes" from CloudSat, and repeat the entire analysis over years of AIRS data. To perform such an analysis, one must discover & access multiple datasets from remote sites, find the space/time "matchups" between instruments swaths and model grids, understand the quality flags and uncertainties for retrieved physical variables, assemble merged datasets, and compute fused products for further scientific and statistical analysis. To meet these large-scale challenges, we are utilizing a Grid computing and dataflow framework, named SciFlo, in which we are deploying a set of versatile and reusable operators for data query, access, subsetting, co-registration, mining, fusion, and advanced statistical analysis. SciFlo is a semantically-enabled ("smart") Grid Workflow system that ties together a peer-to-peer network of computers into an efficient engine for distributed computation. The SciFlo workflow engine enables scientists to do multi-instrument Earth Science by assembling remotely-invokable Web Services (SOAP or http GET URLs), native executables, command-line scripts, and Python codes into a distributed computing flow. A scientist visually authors the graph of operation in the Viz

  8. A new PLL system using full order observer and PLL system modeling in a single phase grid-connected inverter

    DEFF Research Database (Denmark)

    Ko, Youngjong; Park, Kiwoo; Lee, Kyo-Beum

    2011-01-01

    In a grid connected power conversion system, the phase angle information of a grid voltage is very essential for supplying power to the grid since it is used for active and reactive power control. A Phase Locked Loop (PLL) system is used and should be robust because often the actual grid voltages...... are usually distorted by unexpected harmonics. However, conventional PLL systems have steady state errors when distorted voltages are used as a PLL input. Furthermore, using this distorted phase angle in the power control could reduce the output power quality. In this paper, the grid voltages are separated...... into fundamental and harmonic components and a virtual phase voltage is generated from the fundamental component using a Full Order Observer (FOO). Two virtual voltages are used as an input for the PLL system so the phase angle errors can be reduced and the output power quality can be improved. The dynamic...

  9. Analysis of Low-Resistance Neutral Point Grounding Mode in 10kV Power Distribution Grid%10 kV配电网中性点经小电阻接地方式分析

    Institute of Scientific and Technical Information of China (English)

    顾韧; 闫少波

    2015-01-01

    Introduction was made to the low-resistance neutral point grounding mode in 10kV power distribution grid. Analysis was made to the current direction and protection setting mode when the line single phase grounding. This paper discussed a case of total reserve unwanted operation of grounding transformer when the line high-resistance grounding and suggested that the line should fit for the setting value of grounding transformer zero-sequence current. The result shows that in the low-resistance neutral point ground-ing system, if the setting value of grounding transformer zero-sequence current acting as the 10kV system total reserve is less than that of the outgoing line secondary section, the total reserve will turn up unwanted operation.%介绍了10kV配电网中性点经小电阻接地方式,通过对线路单相接地时的电流流向和保护整定方式的分析,讨论了一起线路高阻接地时接地变总后备误动的案例,并对线路和接地变零序电流整定值的配合方式给出了建议。结果表明,中性点经小电阻接地系统中,若作为整个10 kV系统总后备的接地变高压零流整定值小于出线Ⅱ段零序整定值,可能会造成总后备误动作。

  10. Danish experiments with a grid system tested in the North Sea shrimp fishery

    DEFF Research Database (Denmark)

    Madsen, Niels; Hansen, K.E.

    2001-01-01

    can retain marketable catches of roundfish and Norway lobster (Nephrops norvegicus). The grid system was made of polyamide with a fish escape hole at the top and a Norway lobster escape hole at the bottom. Hinges made the grid flexible. The grid system was developed acid tested in a flume tank......), haddock (Melanogrammus aeglefinus). whiting (Merlangius merlangus), saithe (Pollachius virens), Norway pout (Trisopterus esmarki). Norway lobster, herring (Clupea harengus) and witch (Glyptocephalus cynoglossus) but no significant difference in weight of shrimp and monkfish (Lophius piscatorius......) in the first experiment. The grid system was altered in experiment 2 resulting in no significant difference in the catch of cod and saithe above the minimum landing size while the catch of Norway lobster and shrimp improved significantly. Experiments with collecting bags indicated that most fish went through...

  11. Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III -- Grid Interconnection System Evaluator: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Lundstrom, B.; Shirazi, M.; Coddington, M.; Kroposki, B.

    2013-01-01

    This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

  12. Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III - Grid Interconnection System Evaluator

    Energy Technology Data Exchange (ETDEWEB)

    Lundstrom, B.; Shirazi, M.; Coddington, M.; Kroposki, B.

    2013-01-01

    This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

  13. Robust Two Degrees-of-freedom Single-current Control Strategy for LCL-type Grid-Connected DG System under Grid-Frequency Fluctuation and Grid-impedance Variation

    DEFF Research Database (Denmark)

    Zhou, Leming; Chen, Yandong; Luo, An

    2016-01-01

    For LCL-type grid-connected distributed generation(DG) system, the grid-frequency fluctuation and grid-impedance variation affect the active/reactive power control accuracy and resonance peak suppression respectively, which would reduce the system robustness. In this paper, a robust two degrees-of-freedom......-state performances. The stability margin and dynamic response of the overall system are analyzed in detail, and the proper parameters are selected without complicated trial. Finally, Simulation and experimental results verify the proposed control and design strategies....

  14. Impact of Degraded Communication on Interdependent Power Systems: The Application of Grid Splitting

    Directory of Open Access Journals (Sweden)

    Di-An Tian

    2016-08-01

    Full Text Available Communication is increasingly present for managing and controlling critical infrastructures strengthening their cyber interdependencies. In electric power systems, grid splitting is a topical communication-critical application. It amounts to separating a power system into islands in response to an impending instability, e.g., loss of generator synchronism due to a component fault, by appropriately disconnecting transmission lines and grouping synchronous generators. The successful application of grid splitting depends on the communication infrastructure to collect system-wide synchronized measurements and to relay the command to open line switches. Grid splitting may be ineffective if communication is degraded and its outcome may also depend on the system loading conditions. This paper investigates the effects of degraded communication and load variability on grid splitting. To this aim, a communication delay model is coupled with a transient electrical model and applied to the IEEE 39-Bus and the IEEE 118-Bus Test System. Case studies show that the loss of generator synchronism following a fault is mitigated by timely splitting the network into islands. On the other hand, the results show that communication delays and increased network flows can degrade the performance of grid splitting. The developed framework enables the identification of the requirements of the dedicated communication infrastructure for a successful grid-splitting procedure.

  15. 46 CFR 169.676 - Grounded electrical systems.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Grounded electrical systems. 169.676 Section 169.676... Machinery and Electrical Electrical Installations Operating at Potentials of 50 Volts Or More on Vessels of Less Than 100 Gross Tons § 169.676 Grounded electrical systems. (a) Except as provided in paragraph...

  16. Grid-enabled SEE++, A Grid-Based Medical Decision Support System for Eye Muscle Surgery Conference

    CERN Document Server

    Schreiner, W.; Buchberger, M.; Kaltofen, T.

    2006-01-01

    JKU/RISC currently develops in cooperation with Upper Austrian Research (UAR) the SEE-GRID software system. SEE-GRID is based on the SEE++ software for the biomechanical 3D simulation of the human eye and its muscles. SEE++ simulates the common eye muscle surgery techniques in a graphic interactive way that is familiar to an experienced surgeon. SEE++ is world-wide the most advanced software for this purpose; it is used by various hospitals and medical doctors for surgery training and planning, SEE++ deals with the support of diagnosis and treatment of strabismus, which is the common name given to usually persistent or regularly occuring misalignment of the eyes. Strabismus is a visual defect in which eyes point in different directions. A person suffering from it may see double images due to misaligned eyes. SEE++ is able to simulate the result of the Hess-Lancaster test, from which the pathological reason of strabismus can be estimated. The outcome of such an examination is two gaze patterns of blue points a...

  17. Physics design of a 100 keV acceleration grid system for the diagnostic neutral beam for international tokamak experimental reactor.

    Science.gov (United States)

    Singh, M J; De Esch, H P L

    2010-01-01

    This paper describes the physics design of a 100 keV, 60 A H(-) accelerator for the diagnostic neutral beam (DNB) for international tokamak experimental reactor (ITER). The accelerator is a three grid system comprising of 1280 apertures, grouped in 16 groups with 80 apertures per beam group. Several computer codes have been used to optimize the design which follows the same philosophy as the ITER Design Description Document (DDD) 5.3 and the 1 MeV heating and current drive beam line [R. Hemsworth, H. Decamps, J. Graceffa, B. Schunke, M. Tanaka, M. Dremel, A. Tanga, H. P. L. De Esch, F. Geli, J. Milnes, T. Inoue, D. Marcuzzi, P. Sonato, and P. Zaccaria, Nucl. Fusion 49, 045006 (2009)]. The aperture shapes, intergrid distances, and the extractor voltage have been optimized to minimize the beamlet divergence. To suppress the acceleration of coextracted electrons, permanent magnets have been incorporated in the extraction grid, downstream of the cooling water channels. The electron power loads on the extractor and the grounded grids have been calculated assuming 1 coextracted electron per ion. The beamlet divergence is calculated to be 4 mrad. At present the design for the filter field of the RF based ion sources for ITER is not fixed, therefore a few configurations of the same have been considered. Their effect on the transmission of the electrons and beams through the accelerator has been studied. The OPERA-3D code has been used to estimate the aperture offset steering constant of the grounded grid and the extraction grid, the space charge interaction between the beamlets and the kerb design required to compensate for this interaction. All beamlets in the DNB must be focused to a single point in the duct, 20.665 m from the grounded grid, and the required geometrical aimings and aperture offsets have been calculated.

  18. Physics design of a 100 keV acceleration grid system for the diagnostic neutral beam for international tokamak experimental reactor

    Science.gov (United States)

    Singh, M. J.; De Esch, H. P. L.

    2010-01-01

    This paper describes the physics design of a 100 keV, 60 A H- accelerator for the diagnostic neutral beam (DNB) for international tokamak experimental reactor (ITER). The accelerator is a three grid system comprising of 1280 apertures, grouped in 16 groups with 80 apertures per beam group. Several computer codes have been used to optimize the design which follows the same philosophy as the ITER Design Description Document (DDD) 5.3 and the 1 MeV heating and current drive beam line [R. Hemsworth, H. Decamps, J. Graceffa, B. Schunke, M. Tanaka, M. Dremel, A. Tanga, H. P. L. De Esch, F. Geli, J. Milnes, T. Inoue, D. Marcuzzi, P. Sonato, and P. Zaccaria, Nucl. Fusion 49, 045006 (2009)]. The aperture shapes, intergrid distances, and the extractor voltage have been optimized to minimize the beamlet divergence. To suppress the acceleration of coextracted electrons, permanent magnets have been incorporated in the extraction grid, downstream of the cooling water channels. The electron power loads on the extractor and the grounded grids have been calculated assuming 1 coextracted electron per ion. The beamlet divergence is calculated to be 4 mrad. At present the design for the filter field of the RF based ion sources for ITER is not fixed, therefore a few configurations of the same have been considered. Their effect on the transmission of the electrons and beams through the accelerator has been studied. The OPERA-3D code has been used to estimate the aperture offset steering constant of the grounded grid and the extraction grid, the space charge interaction between the beamlets and the kerb design required to compensate for this interaction. All beamlets in the DNB must be focused to a single point in the duct, 20.665 m from the grounded grid, and the required geometrical aimings and aperture offsets have been calculated.

  19. 30 CFR 77.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.

    Science.gov (United States)

    2010-07-01

    ... circuits on high-voltage resistance grounded systems. On and after September 30, 1971, all high-voltage, resistance grounded systems shall include a fail safe ground check circuit or other no less effective device... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on...

  20. Joint Polar Satellite System Common Ground System Overview

    Science.gov (United States)

    Jamilkowski, M. L.; Miller, S. W.; Grant, K. D.

    2012-12-01

    The National Oceanic and Atmospheric Administration (NOAA) and National Aeronautics and Space Administration (NASA) are jointly acquiring the next-generation civilian weather and environmental satellite system: the Joint Polar Satellite System (JPSS). JPSS will contribute the afternoon orbit component and ground processing system of the restructured National Polar-orbiting Operational Environmental Satellite System (NPOESS). As such, JPSS replaces the current Polar-orbiting Operational Environmental Satellites (POES) managed by NOAA and the ground processing component of both Polar-orbiting Operational Environmental Satellites and the Defense Meteorological Satellite Program (DMSP) replacement, previously known as the Defense Weather Satellite System (DWSS), managed by the Department of Defense (DoD). The JPSS satellites will carry a suite of sensors designed to collect meteorological, oceanographic, climatological, and solar-geophysical observations of the earth, atmosphere, and space. The ground processing system for JPSS is known as the JPSS Common Ground System (JPSS CGS), and consists of a Command, Control, and Communications Segment (C3S) and an Interface Data Processing Segment (IDPS). Both segments are developed by Raytheon Intelligence and Information Systems (IIS). The C3S currently flies the Suomi National Polar Partnership (Suomi NPP) satellite and transfers mission data from Suomi NPP and between the ground facilities. The IDPS processes Suomi NPP satellite data to provide Environmental Data Records (EDRs) to NOAA and DoD processing centers operated by the United States government. When the JPSS-1 satellite is launched in early 2017, the responsibilities of the C3S and the IDPS will be expanded to support both Suomi NPP and JPSS-1. The JPSS CGS currently provides data processing for Suomi NPP, generating multiple terabytes per day across over two dozen environmental data products; that workload will be multiplied by two when the JPSS-1 satellite is

  1. Grid-based precision aim system and method for disrupting suspect objects

    Science.gov (United States)

    Gladwell, Thomas Scott; Garretson, Justin; Hobart, Clinton G.; Monda, Mark J.

    2014-06-10

    A system and method for disrupting at least one component of a suspect object is provided. The system has a source for passing radiation through the suspect object, a grid board positionable adjacent the suspect object (the grid board having a plurality of grid areas, the radiation from the source passing through the grid board), a screen for receiving the radiation passing through the suspect object and generating at least one image, a weapon for deploying a discharge, and a targeting unit for displaying the image of the suspect object and aiming the weapon according to a disruption point on the displayed image and deploying the discharge into the suspect object to disable the suspect object.

  2. A techno-economic assessment of grid connected photovoltaic system for hospital building in Malaysia

    Science.gov (United States)

    Mat Isa, Normazlina; Tan, Chee Wei; Yatim, AHM

    2017-07-01

    Conventionally, electricity in hospital building are supplied by the utility grid which uses mix fuel including coal and gas. Due to enhancement in renewable technology, many building shall moving forward to install their own PV panel along with the grid to employ the advantages of the renewable energy. This paper present an analysis of grid connected photovoltaic (GCPV) system for hospital building in Malaysia. A discussion is emphasized on the economic analysis based on Levelized Cost of Energy (LCOE) and total Net Present Post (TNPC) in regards with the annual interest rate. The analysis is performed using Hybrid Optimization Model for Electric Renewables (HOMER) software which give optimization and sensitivity analysis result. An optimization result followed by the sensitivity analysis also being discuss in this article thus the impact of the grid connected PV system has be evaluated. In addition, the benefit from Net Metering (NeM) mechanism also discussed.

  3. A Sensorless Power Reserve Control Strategy for Two-Stage Grid-Connected PV Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2017-01-01

    Due to the still increasing penetration of grid-connected Photovoltaic (PV) systems, advanced active power control functionalities have been introduced in grid regulations. A power reserve control, where namely the active power from the PV panels is reserved during operation, is required for grid...... to achieve the power reserve. In this method, the solar irradiance and temperature measurements that have been used in conventional power reserve control schemes to estimate the available PV power are not required, and thereby being a sensorless approach with reduced cost. Experimental tests have been...... support. In this paper, a cost-effective solution to realize the power reserve for two-stage grid-connected PV systems is proposed. The proposed solution routinely employs a Maximum Power Point Tracking (MPPT) control to estimate the available PV power and a Constant Power Generation (CPG) control...

  4. Sensorless Reserved Power Control Strategy for Two-Stage Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Sangwongwanich, Ariya; Yang, Yongheng; Blaabjerg, Frede

    2016-01-01

    Due to still increasing penetration level of grid-connected Photovoltaic (PV) systems, advanced active power control functionalities have been introduced in grid regulations. A reserved power control, where the active power from the PV panels is reserved during operation, is required for grid...... to achieve the power reserve. In this method, the irradiance measurements that have been used in conventional control schemes to estimate the available PV power are not required, and thereby being a sensorless solution. Simulations and experimental tests have been performed on a 3-kW two-stage single...... support. In this paper, a cost-effective solution to realize the reserved power control for grid-connected PV systems is proposed. The proposed solution routinely employs a Maximum Power Point Tracking (MPPT) control to estimate the available PV power and a Constant Power Generation (CPG) control...

  5. The biometric-based module of smart grid system

    Science.gov (United States)

    Engel, E.; Kovalev, I. V.; Ermoshkina, A.

    2015-10-01

    Within Smart Grid concept the flexible biometric-based module base on Principal Component Analysis (PCA) and selective Neural Network is developed. The formation of the selective Neural Network the biometric-based module uses the method which includes three main stages: preliminary processing of the image, face localization and face recognition. Experiments on the Yale face database show that (i) selective Neural Network exhibits promising classification capability for face detection, recognition problems; and (ii) the proposed biometric-based module achieves near real-time face detection, recognition speed and the competitive performance, as compared to some existing subspaces-based methods.

  6. The on-line electric vehicle wireless electric ground transportation systems

    CERN Document Server

    Cho, Dong

    2017-01-01

    This book details the design and technology of the on-line electric vehicle (OLEV) system and its enabling wireless power-transfer technology, the “shaped magnetic field in resonance” (SMFIR). The text shows how OLEV systems can achieve their three linked important goals: reduction of CO2 produced by ground transportation; improved energy efficiency of ground transportation; and contribution to the amelioration or prevention of climate change and global warming. SMFIR provides power to the OLEV by wireless transmission from underground cables using an alternating magnetic field and the reader learns how this is done. This cable network will in future be part of any local smart grid for energy supply and use thereby exploiting local and renewable energy generation to further its aims. In addition to the technical details involved with design and realization of a fleet of vehicles combined with extensive subsurface charging infrastructure, practical issues such as those involved with pedestrian safety are c...

  7. Simulating the thermal regime and thaw processes of ice-rich permafrost ground with the land-surface model CryoGrid 3

    Science.gov (United States)

    Westermann, S.; Langer, M.; Boike, J.; Heikenfeld, M.; Peter, M.; Etzelmüller, B.; Krinner, G.

    2016-02-01

    Thawing of permafrost in a warming climate is governed by a complex interplay of different processes of which only conductive heat transfer is taken into account in most model studies. However, observations in many permafrost landscapes demonstrate that lateral and vertical movement of water can have a pronounced influence on the thaw trajectories, creating distinct landforms, such as thermokarst ponds and lakes, even in areas where permafrost is otherwise thermally stable. Novel process parameterizations are required to include such phenomena in future projections of permafrost thaw and subsequent climatic-triggered feedbacks. In this study, we present a new land-surface scheme designed for permafrost applications, CryoGrid 3, which constitutes a flexible platform to explore new parameterizations for a range of permafrost processes. We document the model physics and employed parameterizations for the basis module CryoGrid 3, and compare model results with in situ observations of surface energy balance, surface temperatures, and ground thermal regime from the Samoylov permafrost observatory in NE Siberia. The comparison suggests that CryoGrid 3 can not only model the evolution of the ground thermal regime in the last decade, but also consistently reproduce the chain of energy transfer processes from the atmosphere to the ground. In addition, we demonstrate a simple 1-D parameterization for thaw processes in permafrost areas rich in ground ice, which can phenomenologically reproduce both formation of thermokarst ponds and subsidence of the ground following thawing of ice-rich subsurface layers. Long-term simulation from 1901 to 2100 driven by reanalysis data and climate model output demonstrate that the hydrological regime can both accelerate and delay permafrost thawing. If meltwater from thawed ice-rich layers can drain, the ground subsides, as well as the formation of a talik, are delayed. If the meltwater pools at the surface, a pond is formed that enhances heat

  8. Design, Digital Control, and Simulation of a Grid-Connected Photovoltaic Generation System

    OpenAIRE

    Feshara, Hazem; Elharony, Mohamed; Sharaf, Soliman

    2016-01-01

    This paper presents simulation and digital control of a three-phase grid-connected photovoltaic (PV) generation system. The technique used for maximum power point tracking (MPPT) of photovoltaic power is sliding mode (SM) control. Control of power extraction from DC link capacitor is presented. Space vector pulse width modulation (SVPWM) inverter is utilized to deliver power to utility grid. Simulation is performed using PLECS standalone software package and simulation results are shown. Comp...

  9. Second life battery energy storage system for enhancing renewable energy grid integration

    OpenAIRE

    Koch-Ciobotaru, Cosmin; Saez-de Ibarra, Andoni; Martinez-Laserna, Egoitz; Stroe, Daniel-Ioan; Swierczynski, Maciej; Rodríguez Cortés, Pedro

    2015-01-01

    Connecting renewable power plants to the grid must comply with certain codes and requirements. One requirement is the ramp rate constraint, which must be fulfilled in order to avoid penalties. As this service becomes compulsory with an increased grid penetration of renewable, all possible solutions must be explored especially that large battery energy storage systems are still expensive solutions. Thus, in order to make battery investment economic viable, the use of second life batteries is i...

  10. Real-Time Business Intelligence in the MIRABEL Smart Grid System

    DEFF Research Database (Denmark)

    Fischer, Ulrike; Kaulakiene, Dalia; Khalefa, Mohamed

    2012-01-01

    of energy related data, and must be able to react rapidly (but intelligently) when conditions change, leading to substantial real-time business intelligence challenges. This paper discusses these challenges and presents data management solutions in the European smart grid project MIRABEL. These solutions......) data. Experimental studies show that the proposed solutions support important real-time business intelligence tasks in a smart grid system....

  11. The Application of Stationary VOC-PR with PLL for Grid side Converter-based Wind Power Generation System

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Li, Lijuan

    2010-01-01

    Voltage oriented control PR is combined with space vector modulation and phase locked loop to control the grid side converter in wind power generation system in this paper. First the mathematical models of grid side converter and LCL filter as well as grid are given. Then the control strategy of ...

  12. Movable Ground Based Recovery System for Reuseable Space Flight Hardware

    Science.gov (United States)

    Sarver, George L. (Inventor)

    2013-01-01

    A reusable space flight launch system is configured to eliminate complex descent and landing systems from the space flight hardware and move them to maneuverable ground based systems. Precision landing of the reusable space flight hardware is enabled using a simple, light weight aerodynamic device on board the flight hardware such as a parachute, and one or more translating ground based vehicles such as a hovercraft that include active speed, orientation and directional control. The ground based vehicle maneuvers itself into position beneath the descending flight hardware, matching its speed and direction and captures the flight hardware. The ground based vehicle will contain propulsion, command and GN&C functionality as well as space flight hardware landing cushioning and retaining hardware. The ground based vehicle propulsion system enables longitudinal and transverse maneuverability independent of its physical heading.

  13. A GRID CONNECTED PV SYSTEM INTEGRATED THROUGH MULTILEVEL MODULAR CASCADED H-BRIDGE INVERTER BY USING FUZZY LOGIC CONTROLLER

    OpenAIRE

    2016-01-01

    This paper presents a modular cascaded H-bridge multilevel photovoltaic (PV) inverter for three-phase grid-connected applications. The modular cascaded multilevel topology helps to improve the efficiency and flexibility of PV systems. The main abstruse is the harmonization of the DG to the utility grid. Generally current regulated PWM voltage-source inverters (VSI) are used for synchronizing the utility grid with DG source in order to meet the following objectives: 1) To ensure grid stability...

  14. Issues regarding the modelling and simulation of hybrid micro grid systems

    Science.gov (United States)

    Szeidert, I.; Filip, I.; Prostean, O.

    2016-02-01

    The main followed objectives within control strategies dedicated to hybrid micro grid systems (wind/hydro/solar), that operate based on maximum power point tracking (MPPT) techniques are to improve the conversion systems efficiency and to maintain the quality of the produced electrical energy (the voltage and power factor control). One of the main goals of maximum power point tracking strategy is to achieve the harvesting of the maximal possible energy within a pre-set time period. In order to implement the control strategies for micro grid systems that operate at time variable parameter, there are usually required specific transducers (anemometer for wind speed measurement, optical rotational transducers, taco generators, etc.). In the technical literature there are presented several variants of the MPPT techniques, which are particularized at several applications (wind energy conversion systems, solar systems, hydro plants and micro grid hybrid systems). The maximum power point tracking implementations are mainly based on two-level architecture. The inferior level controls the primary variables, while the superior level represents the MPPT control structure. In the paper, authors present some micro grid structures proposed at Politehnica University Timisoara within the frame of a research grant. The paper is focused on the application of MPPT strategies on hybrid micro grid systems. There are presented several structures and control strategies and are highlighted their advantages and disadvantages, together with practical implementation guidelines.

  15. Mission Profile Translation to Capacitor Stresses in Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Ma, Ke; Wang, Huai

    2014-01-01

    DC capacitors are widely adopted in grid-connected PhotoVoltaic(PV) systems for power stabilization and control decoupling. They have become one of the critical components in grid-connected PV inverters in terms of cost, reliability and volume. The electrical and thermal stresses of the DC...... capacitors are varying along with the intermittent solar PV energy (i.e. of weather-dependency) and also the grid conditions (e.g. voltage fault transients). This paper serves to translate real-field mission profiles (i.e. solar irradiance and ambient temperature) into voltage, current, and temperature...... stresses of the DC capacitors under both normal and abnormal grid conditions. As a consequence, this investigation provides new insights into the sizing and reliability prediction of those capacitors with respect to priorart studies. Two study cases on a single-stage PV inverter and a two-stage PV inverter...

  16. Mitigation of Power Quality Problems in Grid-Interactive Distributed Generation System

    Science.gov (United States)

    Bhende, C. N.; Kalam, A.; Malla, S. G.

    2016-04-01

    Having an inter-tie between low/medium voltage grid and distributed generation (DG), both exposes to power quality (PQ) problems created by each other. This paper addresses various PQ problems arise due to integration of DG with grid. The major PQ problems are due to unbalanced and non-linear load connected at DG, unbalanced voltage variations on transmission line and unbalanced grid voltages which severely affect the performance of the system. To mitigate the above mentioned PQ problems, a novel integrated control of distribution static shunt compensator (DSTATCOM) is presented in this paper. DSTATCOM control helps in reducing the unbalance factor of PCC voltage. It also eliminates harmonics from line currents and makes them balanced. Moreover, DSTATCOM supplies the reactive power required by the load locally and hence, grid need not to supply the reactive power. To show the efficacy of the proposed controller, several operating conditions are considered and verified through simulation using MATLAB/SIMULINK.

  17. Evaluation of a grid-connected photovoltaic system in southern Spain

    Energy Technology Data Exchange (ETDEWEB)

    Sidrach-de-Cardona, M. [Universidad de Malaga, Dpto. Fisica Aplicada 2, Malaga (Spain); Lopez, Ll. Mora [Universidad de Malaga, Dpto. Lenguajes y C. Computacion, Malaga (Spain)

    1998-09-01

    The results obtained in the evaluation of a 2 kW{sub p} grid-connected photovoltaic system in Malaga (Spain) are shown. The data set covers from January until December 1997. The energy losses of the system and the most relevant performances of the installation have been quantified. In this period, the system has supplied 2678 kWh to the grid. This means a daily energy average of 7,4 kWh, with a monthly average value of daily system efficiency between 6,1 and 8,0%. According with the obtained results, the South of Spain is an optimum region for the development of grid-connected photovoltaic systems. (Author)

  18. Monitoring and remote failure detection of grid-connected PV systems based on satellite observations

    NARCIS (Netherlands)

    Drews, A.; de Keizer, A.C.; Beyer, H.G.; Lorenz, E.; Betcke, J.W.H.; van Sark, W.G.J.H.M.; Heydenreich, W.; Wiemken, E.; Stettler, S.; Toggweiler, P.; Bofinger, S.; Schneider, M.; Heilscher, G.; Heinemann, D.

    2007-01-01

    Small grid-connected photovoltaic systems up to 5 kWp are often not monitored because advanced surveillance systems are not economical. Hence, some system failures which lead to partial energy losses stay unnoticed for a long time. Even a failure that results in a larger energy deficit can be diffic

  19. Modeling and Simulation of an Unmanned Ground Vehicle Power System

    Science.gov (United States)

    2014-03-28

    Wilhelm, A. N., Surgenor, B. W., and Pharoah, J. G., “Design and evaluation of a micro-fuel-cell-based power system for a mobile robot ,” Mechatronics ...of Michigan, Ann Arbor, MI, USA bU.S. Army RDECOM-TARDEC, Warren, MI, USA ABSTRACT Long-duration missions challenge ground robot systems with respect...to energy storage and efficient conversion to power on demand. Ground robot systems can contain multiple power sources such as fuel cell, battery and

  20. A Quarter Active Suspension System Based Ground-Hook Controller

    OpenAIRE

    Turnip Arjon

    2016-01-01

    An alternative design technique for active suspension system of vehicle using a developved ground-hook damping system as a reference is proposed. The controller parameters are determined using Lyapunov method and can be tuned to precisely achieve the type of desired response which given by reference model. The simulation result show that the designed active suspension system based ground-hook reference model is able to significantly improve the ride comfort and the road holding compared with ...

  1. Structured grid technology to enable flow simulation in an integrated system environment

    Science.gov (United States)

    Remotigue, Michael Gerard

    An application-driven Computational Fluid Dynamics (CFD) environment needs flexible and general tools to effectively solve complex problems in a timely manner. In addition, reusable, portable, and maintainable specialized libraries will aid in rapidly developing integrated systems or procedures. The presented structured grid technology enables the flow simulation for complex geometries by addressing grid generation, grid decomposition/solver setup, solution, and interpretation. Grid generation is accomplished with the graphical, arbitrarily-connected, multi-block structured grid generation software system (GUM-B) developed and presented here. GUM-B is an integrated system comprised of specialized libraries for the graphical user interface and graphical display coupled with a solid-modeling data structure that utilizes a structured grid generation library and a geometric library based on Non-Uniform Rational B-Splines (NURBS). A presented modification of the solid-modeling data structure provides the capability for arbitrarily-connected regions between the grid blocks. The presented grid generation library provides algorithms that are reliable and accurate. GUM-B has been utilized to generate numerous structured grids for complex geometries in hydrodynamics, propulsors, and aerodynamics. The versatility of the libraries that compose GUM-B is also displayed in a prototype to automatically regenerate a grid for a free-surface solution. Grid decomposition and solver setup is accomplished with the graphical grid manipulation and repartition software system (GUMBO) developed and presented here. GUMBO is an integrated system comprised of specialized libraries for the graphical user interface and graphical display coupled with a structured grid-tools library. The described functions within the grid-tools library reduce the possibility of human error during decomposition and setup for the numerical solver by accounting for boundary conditions and connectivity. GUMBO is

  2. Electrical Market Management Considering Power System Constraints in Smart Distribution Grids

    Directory of Open Access Journals (Sweden)

    Poria Hasanpor Divshali

    2016-05-01

    Full Text Available Rising demand, climate change, growing fuel costs, outdated power system infrastructures, and new power generation technologies have made renewable distribution generators very attractive in recent years. Because of the increasing penetration level of renewable energy sources in addition to the growth of new electrical demand sectors, such as electrical vehicles, the power system may face serious problems and challenges in the near future. A revolutionary new power grid system, called smart grid, has been developed as a solution to these problems. The smart grid, equipped with modern communication and computation infrastructures, can coordinate different parts of the power system to enhance energy efficiency, reliability, and quality, while decreasing the energy cost. Since conventional distribution networks lack smart infrastructures, much research has been recently done in the distribution part of the smart grid, called smart distribution grid (SDG. This paper surveys contemporary literature in SDG from the perspective of the electricity market in addition to power system considerations. For this purpose, this paper reviews current demand side management methods, supply side management methods, and electrical vehicle charging and discharging techniques in SDG and also discusses their drawbacks. We also present future research directions to tackle new and existing challenges in the SDG.

  3. Introduction to grid computing

    CERN Document Server

    Magoules, Frederic; Tan, Kiat-An; Kumar, Abhinit

    2009-01-01

    A Thorough Overview of the Next Generation in ComputingPoised to follow in the footsteps of the Internet, grid computing is on the verge of becoming more robust and accessible to the public in the near future. Focusing on this novel, yet already powerful, technology, Introduction to Grid Computing explores state-of-the-art grid projects, core grid technologies, and applications of the grid.After comparing the grid with other distributed systems, the book covers two important aspects of a grid system: scheduling of jobs and resource discovery and monitoring in grid. It then discusses existing a

  4. Study of the integration of distributed generation systems in the grid: application in micro-grids; Etude de structures d'integration des systemes de generation decentralisee: application aux microreseaux

    Energy Technology Data Exchange (ETDEWEB)

    Gaztanaga Arantzamendi, H

    2006-12-15

    The present PhD deals with an original micro-grid concept and its application as a Renewable Energy Source's (RES) grid integration scheme. This micro-grid is composed of RES generators as well as support systems that incorporate additional functionalities in order to improve RES integration into the grid. According to this concept, two practical micro-grid applications have been studied in detail: a residential micro-grid and a wind farm supported by DFACTS systems (STATCOM and DVR). In both applications, the control structures which are implemented at different levels and applied to the different micro-grid elements have been developed, analyzed by means of off-line simulations and finally validated in real-time conditions with physical reduced-scale prototypes. (author)

  5. Development and Testing of the Glenn Research Center Visitor's Center Grid-Tied Photovoltaic Power System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2009-01-01

    The NASA Glenn Research Center (GRC) has developed, installed, and tested a 12 kW DC grid-tied photovoltaic (PV) power system at the GRC Visitor s Center. This system utilizes a unique ballast type roof mount for installing the photovoltaic panels on the roof of the Visitor s Center with no alterations or penetrations to the roof. The PV system has generated in excess of 15000 kWh since operation commenced in August 2008. The PV system is providing power to the GRC grid for use by all. Operation of the GRC Visitor s Center PV system has been completely trouble free. A grid-tied PV power system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility. The project transfers space technology to terrestrial use via nontraditional partners. GRC personnel glean valuable experience with PV power systems that are directly applicable to various space power systems, and provides valuable space program test data. PV power systems help to reduce harmful emissions and reduce the Nation s dependence on fossil fuels. Power generated by the PV system reduces the GRC utility demand, and the surplus power aids the community. Present global energy concerns reinforce the need for the development of alternative energy systems. Modern PV panels are readily available, reliable, efficient, and economical with a life expectancy of at least 25 years. Modern electronics has been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy of at least 25 years. Based upon the success of the GRC Visitor s Center PV system, additional PV power system expansion at GRC is under consideration. The GRC Visitor s Center grid-tied PV power system was successfully designed and developed which served to validate the basic principles

  6. Improving Overhead Computation and pre-processing Time for Grid Scheduling System

    CERN Document Server

    Bouyer, Asgarali; Abdullah, Abdul Hanan

    2010-01-01

    Computational Grid is enormous environments with heterogeneous resources and stable infrastructures among other Internet-based computing systems. However, the managing of resources in such systems has its special problems. Scheduler systems need to get last information about participant nodes from information centers for the purpose of firmly job scheduling. In this paper, we focus on online updating resource information centers with processed and provided data based on the assumed hierarchical model. A hybrid knowledge extraction method has been used to classifying grid nodes based on prediction of jobs' features. An affirmative point of this research is that scheduler systems don't waste extra time for getting up-to-date information of grid nodes. The experimental result shows the advantages of our approach compared to other conservative methods, especially due to its ability to predict the behavior of nodes based on comprehensive data tables on each node.

  7. Classical ground states of symmetric Heisenberg spin systems

    CERN Document Server

    Schmidt, H J

    2003-01-01

    We investigate the ground states of classical Heisenberg spin systems which have point group symmetry. Examples are the regular polygons (spin rings) and the seven quasi-regular polyhedra including the five Platonic solids. For these examples, ground states with special properties, e.g. coplanarity or symmetry, can be completely enumerated using group-theoretical methods. For systems having coplanar (anti-) ground states with vanishing total spin we also calculate the smallest and largest energies of all states having a given total spin S. We find that these extremal energies depend quadratically on S and prove that, under certain assumptions, this happens only for systems with coplanar S = 0 ground states. For general systems the corresponding parabolas represent lower and upper bounds for the energy values. This provides strong support and clarifies the conditions for the so-called rotational band structure hypothesis which has been numerically established for many quantum spin systems.

  8. The Earth Observing System (EOS) Ground System: Leveraging an Existing Operational Ground System Infrastructure to Support New Missions

    Science.gov (United States)

    Hardison, David; Medina, Johnny; Dell, Greg

    2016-01-01

    The Earth Observer System (EOS) was officially established in 1990 and went operational in December 1999 with the launch of its flagship spacecraft Terra. Aqua followed in 2002 and Aura in 2004. All three spacecraft are still operational and producing valuable scientific data. While all are beyond their original design lifetime, they are expected to remain viable well into the 2020s. The EOS Ground System is a multi-mission system based at NASA Goddard Space Flight Center that supports science and spacecraft operations for these three missions. Over its operational lifetime to date, the EOS Ground System has evolved as needed to accommodate mission requirements. With an eye towards the future, several updates are currently being deployed. Subsystem interconnects are being upgraded to reduce data latency and improve system performance. End-of-life hardware and operating systems are being replaced to mitigate security concerns and eliminate vendor support gaps. Subsystem hardware is being consolidated through the migration to Virtual Machine based platforms. While mission operations autonomy was not a design goal of the original system concept, there is an active effort to apply state-of-the-art products from the Goddard Mission Services Evolution Center (GMSEC) to facilitate automation where possible within the existing heritage architecture. This presentation will provide background information on the EOS ground system architecture and evolution, discuss latest improvements, and conclude with the results of a recent effort that investigated how the current system could accommodate a proposed new earth science mission.

  9. Analysis of Grid Based Distributed Data Mining System for Service Oriented Frameworks

    Directory of Open Access Journals (Sweden)

    Praseeda Manoj

    2013-01-01

    Full Text Available Distribution of data and computation allows for solving larger problems and execute applications that are distributed in nature. A Grid is a distributed computing infrastructure that enables to manage large amount of data and run business applications supporting consumers and end users. The Grid can play a significant role in providing an effective computational infrastructure that enables coordinated resource sharing within dynamic organizations. There have been several systems proposed to build distributed data mining. This paper analyses different grid based distributed data mining applications which help to give an overview of how Grid computing can be used to support distributed data mining. In addition, the synergy between data mining and grid technology is also discussed. This concept is implemented in Weka4WS, a framework that extends the widely used open source Weka toolkit to support distributed data mining on WSRF-enabled Grids . Weka4WS adopts the WSRF technology for running remote data mining algorithms and managing distributed computations.

  10. A hybrid grid method in an auxiliary coordinate system for irregular fluid-solid interface modelling

    Science.gov (United States)

    Qu, Yingming; Huang, Jianping; Li, Zhenchun; Li, Jinli

    2017-03-01

    Seismic wave propagation in a fluid-solid environment cannot be simulated with a single wave equation, but can be described by use of the acoustic and viscoelastic wave equations for their respective fluid and solid parts. Proper boundary conditions at the fluid-solid interface based on the relationship between pressure and stress are crucial when combining the two different wave equations. Traditional finite difference methods have had difficulties in dealing with the irregular fluid-solid interface topography. The Cartesian grids discretization leads to artificial reflections and diffractions during the conversion between acoustic wave and elastic waves. We propose a variable coordinate transformation methodology to simulate seismic waves in a fluid-solid environment. An irregular fluid-solid interface can be transformed into a horizontal interface, so that pressure and stress can be well converted. We also introduce a multiblock coordinate transformation (MCT) method which meshes each layer with curvilinear grids to transform the interface topography into a horizontal one, thereby allocating vertical sampling points adaptively. The grid size is determined adaptively based on the shape and the parameters of the target area, which reduces in size in when the layers are thin or exhibit low velocities. A Lebedev-standard staggered grid scheme is applied to the MCT method to reduce both the computational cost associated with the Lebedev grid scheme and the instability in the auxiliary coordinate system when using a standard staggered grid scheme.

  11. Cyber-Physical System Security of a Power Grid: State-of-the-Art

    Directory of Open Access Journals (Sweden)

    Chih-Che Sun

    2016-07-01

    Full Text Available As part of the smart grid development, more and more technologies are developed and deployed on the power grid to enhance the system reliability. A primary purpose of the smart grid is to significantly increase the capability of computer-based remote control and automation. As a result, the level of connectivity has become much higher, and cyber security also becomes a potential threat to the cyber-physical systems (CPSs. In this paper, a survey of the state-of-the-art is conducted on the cyber security of the power grid concerning issues of: (1 the structure of CPSs in a smart grid; (2 cyber vulnerability assessment; (3 cyber protection systems; and (4 testbeds of a CPS. At Washington State University (WSU, the Smart City Testbed (SCT has been developed to provide a platform to test, analyze and validate defense mechanisms against potential cyber intrusions. A test case is provided in this paper to demonstrate how a testbed helps the study of cyber security and the anomaly detection system (ADS for substations.

  12. Distributed Energy Systems Integration and Demand Optimization for Autonomous Operations and Electric Grid Transactions

    Energy Technology Data Exchange (ETDEWEB)

    Ghatikar, Girish [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Greenlots, San Francisco, CA (United States); Mashayekh, Salman [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stadler, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Center for Energy and Innovation Technologies (Austria); Yin, Rongxin [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Liu, Zhenhua [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-11-29

    Distributed power systems in the U.S. and globally are evolving to provide reliable and clean energy to consumers. In California, existing regulations require significant increases in renewable generation, as well as identification of customer-side distributed energy resources (DER) controls, communication technologies, and standards for interconnection with the electric grid systems. As DER deployment expands, customer-side DER control and optimization will be critical for system flexibility and demand response (DR) participation, which improves the economic viability of DER systems. Current DER systems integration and communication challenges include leveraging the existing DER and DR technology and systems infrastructure, and enabling optimized cost, energy and carbon choices for customers to deploy interoperable grid transactions and renewable energy systems at scale. Our paper presents a cost-effective solution to these challenges by exploring communication technologies and information models for DER system integration and interoperability. This system uses open standards and optimization models for resource planning based on dynamic-pricing notifications and autonomous operations within various domains of the smart grid energy system. It identifies architectures and customer engagement strategies in dynamic DR pricing transactions to generate feedback information models for load flexibility, load profiles, and participation schedules. The models are tested at a real site in California—Fort Hunter Liggett (FHL). Furthermore, our results for FHL show that the model fits within the existing and new DR business models and networked systems for transactive energy concepts. Integrated energy systems, communication networks, and modeling tools that coordinate supply-side networks and DER will enable electric grid system operators to use DER for grid transactions in an integrated system.

  13. Job system generation in grid taking into account user preferences

    Directory of Open Access Journals (Sweden)

    D. M. Yemelyanov

    2016-01-01

    Full Text Available Distributed computing environments like Grid are characterized by heterogeneity, low cohesion and dynamic structure of computing nodes. This is why the task of resource scheduling in such environments is complex. Different approaches to job scheduling in grid exist. Some of them use economic principles. Economic approaches to scheduling have shown their efficiency. One of such approaches is cyclic scheduling scheme which is considered in this paper.Cyclic scheduling scheme takes into account the preferences of computing environment users by means of an optimization criterion, which is included in the resource request. Besides, the scheme works cyclically by scheduling a certain job batch at each scheduling step. This is why there is a preliminary scheduling step which is job batch generation.The purpose of this study was to estimate the infl uence of job batch structure by the user criterion on the degree of its satisfaction. In other words we had to find the best way to form the batch with relation to the user optimization criterion. For example if it is more efficient to form the batch with jobs with the same criterion value or with different criterion values. Also we wanted to find the combination of criterion values which would give the most efficient scheduling results.To achieve this purpose an experiment in a simulation environment was conducted. The experiment consisted of scheduling of job batches with different values of the user criterion, other parameters of the resource request and the characteristics of the computing environment being the same. Three job batch generation strategies were considered. In the first strategy the batch consisted of jobs with the same criterion value. In the second strategy the batch consisted of jobs with all the considered criteria equally likely. The third strategy was similar to the second one, but only two certain criteria were considered. The third strategy was considered in order to find the most

  14. Allocating SMART Reliability and Maintainability Goals to NASA Ground Systems

    Science.gov (United States)

    Gillespie, Amanda; Monaghan, Mark

    2013-01-01

    This paper will describe the methodology used to allocate Reliability and Maintainability (R&M) goals to Ground Systems Development and Operations (GSDO) subsystems currently being designed or upgraded.

  15. Global Renewable Energy-Based Electricity Generation and Smart Grid System for Energy Security

    Directory of Open Access Journals (Sweden)

    M. A. Islam

    2014-01-01

    Full Text Available Energy is an indispensable factor for the economic growth and development of a country. Energy consumption is rapidly increasing worldwide. To fulfill this energy demand, alternative energy sources and efficient utilization are being explored. Various sources of renewable energy and their efficient utilization are comprehensively reviewed and presented in this paper. Also the trend in research and development for the technological advancement of energy utilization and smart grid system for future energy security is presented. Results show that renewable energy resources are becoming more prevalent as more electricity generation becomes necessary and could provide half of the total energy demands by 2050. To satisfy the future energy demand, the smart grid system can be used as an efficient system for energy security. The smart grid also delivers significant environmental benefits by conservation and renewable generation integration.

  16. Data Mining and Visualization of Grid-Based City Emergency System

    Institute of Scientific and Technical Information of China (English)

    XUE Jingsheng; SUN Jizhou; LIU Muxing; ZHANG Xu; HE Hong

    2005-01-01

    A cluster analyzing algorithm based on grids is introduced in this paper,which is applied to data mining in the city emergency system. In the previous applications, data mining was based on the method of analyzing points and lines, which was not efficient enough in dealing with the geographic information in units of police areas. The proposed algorithm maps an event set stored as a point set to a grid unit set, utilizes the cluster algorithm based on grids to find out all the clusters, and shows the results in the method of visualization. The algorithm performs well when dealing with high dimensional data sets and immense data. It is suitable for the data mining based on geogra-phic information system and is supportive to decision-makings in the city emergency system.

  17. Global Renewable Energy-Based Electricity Generation and Smart Grid System for Energy Security

    Science.gov (United States)

    Islam, M. A.; Hasanuzzaman, M.; Rahim, N. A.; Nahar, A.; Hosenuzzaman, M.

    2014-01-01

    Energy is an indispensable factor for the economic growth and development of a country. Energy consumption is rapidly increasing worldwide. To fulfill this energy demand, alternative energy sources and efficient utilization are being explored. Various sources of renewable energy and their efficient utilization are comprehensively reviewed and presented in this paper. Also the trend in research and development for the technological advancement of energy utilization and smart grid system for future energy security is presented. Results show that renewable energy resources are becoming more prevalent as more electricity generation becomes necessary and could provide half of the total energy demands by 2050. To satisfy the future energy demand, the smart grid system can be used as an efficient system for energy security. The smart grid also delivers significant environmental benefits by conservation and renewable generation integration. PMID:25243201

  18. Reliable Grid Condition Detection and Control of Single-Phase Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai

    The constant growth of Distributed Power Generation Systems (DPGS) presents an efficient and economic way of generating electricity closer to the load(s). The DPGS can contribute to an efficient and renewable electricity future by potentially: increasing the use of renewable sources of energy......; improving the efficiency of the electricity system by reducing transmission and distribution losses; improving the security of the electricity supply through increased diversity of supply and reduced vulnerability to simultaneous system failures. However, the new trend of using DPGS comes also with a suite...... of new challenges. One of the challenges is the interaction between the DPGS and the utility grid. As a consequence, grid interconnection requirements applying to distributed generation are continuously updated in order to maintain the quality and the stability of the utility grid. The new upcoming...

  19. Study on Battery Capacity for Grid-connection Power Planning with Forecasts in Clustered Photovoltaic Systems

    Science.gov (United States)

    Shimada, Takae; Kawasaki, Norihiro; Ueda, Yuzuru; Sugihara, Hiroyuki; Kurokawa, Kosuke

    This paper aims to clarify the battery capacity required by a residential area with densely grid-connected photovoltaic (PV) systems. This paper proposes a planning method of tomorrow's grid-connection power from/to the external electric power system by using demand power forecasting and insolation forecasting for PV power predictions, and defines a operation method of the electricity storage device to control the grid-connection power as planned. A residential area consisting of 389 houses consuming 2390 MWh/year of electricity with 2390kW PV systems is simulated based on measured data and actual forecasts. The simulation results show that 8.3MWh of battery capacity is required in the conditions of half-hour planning and 1% or less of planning error ratio and PV output limiting loss ratio. The results also show that existing technologies of forecasting reduce required battery capacity to 49%, and increase the allowable installing PV amount to 210%.

  20. Global renewable energy-based electricity generation and smart grid system for energy security.

    Science.gov (United States)

    Islam, M A; Hasanuzzaman, M; Rahim, N A; Nahar, A; Hosenuzzaman, M

    2014-01-01

    Energy is an indispensable factor for the economic growth and development of a country. Energy consumption is rapidly increasing worldwide. To fulfill this energy demand, alternative energy sources and efficient utilization are being explored. Various sources of renewable energy and their efficient utilization are comprehensively reviewed and presented in this paper. Also the trend in research and development for the technological advancement of energy utilization and smart grid system for future energy security is presented. Results show that renewable energy resources are becoming more prevalent as more electricity generation becomes necessary and could provide half of the total energy demands by 2050. To satisfy the future energy demand, the smart grid system can be used as an efficient system for energy security. The smart grid also delivers significant environmental benefits by conservation and renewable generation integration.

  1. Grid integration and smart grid implementation of emerging technologies in electric power systems through approximate dynamic programming

    Science.gov (United States)

    Xiao, Jingjie

    A key hurdle for implementing real-time pricing of electricity is a lack of consumers' responses. Solutions to overcome the hurdle include the energy management system that automatically optimizes household appliance usage such as plug-in hybrid electric vehicle charging (and discharging with vehicle-to-grid) via a two-way communication with the grid. Real-time pricing, combined with household automation devices, has a potential to accommodate an increasing penetration of plug-in hybrid electric vehicles. In addition, the intelligent energy controller on the consumer-side can help increase the utilization rate of the intermittent renewable resource, as the demand can be managed to match the output profile of renewables, thus making the intermittent resource such as wind and solar more economically competitive in the long run. One of the main goals of this dissertation is to present how real-time retail pricing, aided by control automation devices, can be integrated into the wholesale electricity market under various uncertainties through approximate dynamic programming. What distinguishes this study from the existing work in the literature is that whole- sale electricity prices are endogenously determined as we solve a system operator's economic dispatch problem on an hourly basis over the entire optimization horizon. This modeling and algorithm framework will allow a feedback loop between electricity prices and electricity consumption to be fully captured. While we are interested in a near-optimal solution using approximate dynamic programming; deterministic linear programming benchmarks are use to demonstrate the quality of our solutions. The other goal of the dissertation is to use this framework to provide numerical evidence to the debate on whether real-time pricing is superior than the current flat rate structure in terms of both economic and environmental impacts. For this purpose, the modeling and algorithm framework is tested on a large-scale test case

  2. Measured Off-Grid LED Lighting System Performance

    Energy Technology Data Exchange (ETDEWEB)

    Granderson, Jessica; Galvin, James; Bolotov, Dmitriy; Clear, Robert; Jacobson, Arne; Mills, Evan

    2008-12-18

    This report is a product of our ongoing effort to support the development of high-quality yet affordable products for off-grid lighting in the developing world that have good potential to succeed in the market. The effort includes work to develop low-cost testing procedures, to identify useful performance metrics, and to facilitate the development of industry standards and product rating protocols. We conducted laboratory testing of nine distinct product lines. In some cases we also tested multiple generations of a single product line and/or operating modes for a product. The resultsare summarized in Table 1. We found that power consumption and light output varied by nearly a factor of 12, with efficacy varying by a factor of more than six. Of particular note, overall luminous efficacy varied from 8.2 to 53.1 lumens per watt. Color quality indices variedmaterially, especially for correlated color temperature. Maximum illuminance, beamcandlepower, and luminance varied by 8x, 32x, and 61x respectively, suggesting considerable differences among products in terms of service levels and visual comfort. Glare varied by1.4x, and was above acceptable thresholds in most cases. Optical losses play a role in overall performance, varying by a factor of 3.2 and ranging as high as 24percent. These findings collectively indicate considerable potential for improved product design.

  3. Optimization Techniques for Dimensionally Truncated Sparse Grids on Heterogeneous Systems

    KAUST Repository

    Deftu, A.

    2013-02-01

    Given the existing heterogeneous processor landscape dominated by CPUs and GPUs, topics such as programming productivity and performance portability have become increasingly important. In this context, an important question refers to how can we develop optimization strategies that cover both CPUs and GPUs. We answer this for fastsg, a library that provides functionality for handling efficiently high-dimensional functions. As it can be employed for compressing and decompressing large-scale simulation data, it finds itself at the core of a computational steering application which serves us as test case. We describe our experience with implementing fastsg\\'s time critical routines for Intel CPUs and Nvidia Fermi GPUs. We show the differences and especially the similarities between our optimization strategies for the two architectures. With regard to our test case for which achieving high speedups is a "must" for real-time visualization, we report a speedup of up to 6.2x times compared to the state-of-the-art implementation of the sparse grid technique for GPUs. © 2013 IEEE.

  4. Theory of ground state factorization in quantum cooperative systems.

    Science.gov (United States)

    Giampaolo, Salvatore M; Adesso, Gerardo; Illuminati, Fabrizio

    2008-05-16

    We introduce a general analytic approach to the study of factorization points and factorized ground states in quantum cooperative systems. The method allows us to determine rigorously the existence, location, and exact form of separable ground states in a large variety of, generally nonexactly solvable, spin models belonging to different universality classes. The theory applies to translationally invariant systems, irrespective of spatial dimensionality, and for spin-spin interactions of arbitrary range.

  5. Optimized ground-coupled heat pump system design for northern climate applications. [Including ground coil

    Energy Technology Data Exchange (ETDEWEB)

    Catan, M.A.; Baxter, V.D.

    1985-01-01

    This paper addresses the question of the performance of a ground coupled heat pump (GCHP) system with a water - source heat pump package designed expressly for such systems operating in a northern climate. The project objective was to minimize the life-cycle cost of a GCHP system by optimizing the design of both the heat pump package and the ground coil in concert. In order to achieve this objective, a number of modelling tools were developed or modified to analyze the heat pump's performance and cost and the ground coil's performance. The life-cycle cost of a GCHP system (water-source heat pump with a horizontal ground coil) for an 1800 ft/sup 2/ (167 m/sup 2/) house in Pittsburgh, PA, was minimized over a 7 year economic life. Simple payback for the optimized GCHP system, relative to conventional air-source heat pumps, was under 3 years. The water-source heat pump package resulting from this optimization is calculated to cost 21% more than its conventional counterpart with a heating coefficient of performance (COP) about 20% higher, and a cooling COP about 23% higher. In the GCHP system modeled, its annual energy savings are predicted to be about 11% compared to a system designed around the conventional heat pump while having about the same installation cost. The major conclusion of this study is - GCHP system performance improvement can be attained by improving the water-source heat pump package at less cost than by buying more ground coil. The following conclusions were drawn from the steady-state performance optimization results: (1) By adding about $100.00 to the manufacturer's cost off construction, both the heating and cooling COPs can be improved by 20% or more. (2) Cooling COP need not be sacrificed for the sake of heating performance and vice versa. 13 refs., 11 figs., 12 tabs.

  6. Efficient Temperature-Dependent Green's Functions Methods for Realistic Systems: Compact Grids for Orthogonal Polynomial Transforms.

    Science.gov (United States)

    Kananenka, Alexei A; Phillips, Jordan J; Zgid, Dominika

    2016-02-01

    The Matsubara Green's function that is used to describe temperature-dependent behavior is expressed on a numerical grid. While such a grid usually has a couple of hundred points for low-energy model systems, for realistic systems with large basis sets the size of an accurate grid can be tens of thousands of points, constituting a severe computational and memory bottleneck. In this paper, we determine efficient imaginary time grids for the temperature-dependent Matsubara Green's function formalism that can be used for calculations on realistic systems. We show that, because of the use of an orthogonal polynomial transform, we can restrict the imaginary time grid to a few hundred points and reach micro-Hartree accuracy in the electronic energy evaluation. Moreover, we show that only a limited number of orthogonal polynomial expansion coefficients are necessary to preserve accuracy when working with a dual representation of the Green's function or self-energy and transforming between the imaginary time and frequency domain.

  7. Efficient temperature-dependent Green's functions methods for realistic systems: compact grids for orthogonal polynomial transforms

    CERN Document Server

    Kananenka, Alexei A; Zgid, Dominika

    2015-01-01

    The temperature-dependent Matsubara Green's function that is used to describe temperature-dependent behavior is expressed on a numerical grid. While such a grid usually has a couple of hundred points for low-energy model systems, for realistic systems in large basis sets the size of an accurate grid can be tens of thousands of points, constituting a severe computational and memory bottleneck. In this paper, we determine efficient imaginary time grids for the temperature-dependent Matsubara Green's function formalism that can be used for calculations on realistic systems. We show that due to the use of orthogonal polynomial transform, we can restrict the imaginary time grid to few hundred points and reach micro-Hartree accuracy in the electronic energy evaluation. Moreover, we show that only a limited number of orthogonal polynomial expansion coefficients are necessary to preserve accuracy when working with a dual representation of Green's function or self-energy and transforming between the imaginary time and...

  8. Impact of Rural Grid-Connected Photovoltaic Generation Systems on Power Quality

    Directory of Open Access Journals (Sweden)

    Rita Pinto

    2016-09-01

    Full Text Available Photovoltaic (PV generation systems have been increasingly used to generate electricity from renewable sources, attracting a growing interest. Recently, grid connected PV micro-generation facilities in individual homes have increased due to governmental policies as well as greater attention by industry. As low voltage (LV distribution systems were built to make energy flow in one direction, the power feed-in of PV generation in rural low-voltage grids can influence power quality (PQ as well as facility operation and reliability. This paper presents results on PQ analysis of a real PV generation facility connected to a rural low-voltage grid. Voltage fluctuations and voltage harmonic contents were observed. Statistical analysis shows a negative impact on PQ produced by this PV facility and also that only a small fraction of the energy available during a sunny day is converted, provoking losses of revenue and forcing the converter to work in an undesirable operating mode. We discuss the disturbances imposed upon the grid and their outcome regarding technical and economic viability of the PV system, as well as possible solutions. A low-voltage grid strengthening has been suggested and implemented. After that a new PQ analysis shows an improvement in the impact upon PQ, making this facility economically viable.

  9. Semi-implicit integration factor methods on sparse grids for high-dimensional systems

    Science.gov (United States)

    Wang, Dongyong; Chen, Weitao; Nie, Qing

    2015-07-01

    Numerical methods for partial differential equations in high-dimensional spaces are often limited by the curse of dimensionality. Though the sparse grid technique, based on a one-dimensional hierarchical basis through tensor products, is popular for handling challenges such as those associated with spatial discretization, the stability conditions on time step size due to temporal discretization, such as those associated with high-order derivatives in space and stiff reactions, remain. Here, we incorporate the sparse grids with the implicit integration factor method (IIF) that is advantageous in terms of stability conditions for systems containing stiff reactions and diffusions. We combine IIF, in which the reaction is treated implicitly and the diffusion is treated explicitly and exactly, with various sparse grid techniques based on the finite element and finite difference methods and a multi-level combination approach. The overall method is found to be efficient in terms of both storage and computational time for solving a wide range of PDEs in high dimensions. In particular, the IIF with the sparse grid combination technique is flexible and effective in solving systems that may include cross-derivatives and non-constant diffusion coefficients. Extensive numerical simulations in both linear and nonlinear systems in high dimensions, along with applications of diffusive logistic equations and Fokker-Planck equations, demonstrate the accuracy, efficiency, and robustness of the new methods, indicating potential broad applications of the sparse grid-based integration factor method.

  10. Grid connection of active stall wind farms using a VSC based DC transmission system

    DEFF Research Database (Denmark)

    Iov, Florin; Sorensen, Paul; Hansen, Anca-Daniela;

    2005-01-01

    are fulfilled. However, the traditional squirrel-cage generators based wind turbines/wind farms directly connected to the grid have less control capabilities. These wind turbines/farms cannot regulate their production and contribute to power system stability. A DC transmission system for connection...

  11. Analysis of off-grid hybrid wind turbine/solar PV water pumping systems

    Science.gov (United States)

    While many remote water pumping systems exist (e.g. mechanical windmills, solar photovoltaic , wind-electric, diesel powered), very few combine both the wind and solar energy resources to possibly improve the reliability and the performance of the system. In this paper, off-grid wind turbine (WT) a...

  12. Experimental grid access for dynamic discovery and data transfer in distributed interactive simulation systems

    NARCIS (Netherlands)

    A. Tirado-Ramos; K. Zajac; Z. Zhao; P.M.A. Sloot; G.D. van Albada; M. Bubak

    2003-01-01

    Interactive Problem Solving Environments (PSEs) offer an integrated approach for constructing and running complex systems, such as distributed simulation systems. New distributed infrastructures, like the Grid, support the access to a large variety of core services and resources that can be used by

  13. Performance Analysis of Grid Integrated Hydro and Solar Based Hybrid Systems

    Directory of Open Access Journals (Sweden)

    Sweeka Meshram

    2013-01-01

    Full Text Available The renewable energy systems (RESs are an attractive option to electrify the community as they are environment friendly, free of cost, and all-pervading. The efficiency of these energy systems is very low and can be improved by integrating them in parallel. In this paper, hydro (7.5 kW and solar systems (10 kW are taken as RESs and connected with the utility grid. Due to the intermittent nature of both the hydro and photovoltaic energy sources, utility grid is connected to the system for ensuring the continuous power flow. The hydro power generation system uses the self excited induction generator (SEIG and converters. The AC/DC/AC converter is used as interface to connect the hydro turbine to the utility grid to adjust the generated voltage to the utility grid voltage. The solar generation system is the combination of PV array, boost converter, and solar inverter. The control of both the hydro and solar power plants is provided through the constant current controller. The analysis has been done to verify the existence of the proposed system. Results demonstrate that the proposed system is able to be put into service and can feed the community.

  14. Benchmarking of Phase Locked Loop based Synchronization Techniques for Grid-Connected Inverter Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Hadjidemetriou, Lenos; Blaabjerg, Frede

    2015-01-01

    , becoming inevitable challenges to the synchronization of the grid-connected renewable energy systems. In order to ensure the quality of the power generation from the renewables, robust and reliable synchronization methods are in demand. Among the prior-art solutions, Phase Locked Loop (PLL) based...... synchronization methods have gained much popularity in grid-connected applications. However, an appropriate selection and thus a proper design of the selected PLL synchronization remain of interest in practice, especially for single-phase systems. Therefore, in this paper, a benchmarking of the main PLL...

  15. Analysis of Three-Phase Rectifier Systems with Controlled DC-Link Current Under Unbalanced Grids

    DEFF Research Database (Denmark)

    Kumar, Dinesh; Davari, Pooya; Zare, Firuz

    2017-01-01

    Voltage unbalance is the most common disturbance in distribution networks, which give undesirable effects on many grid connected power electronics systems including Adjustable Speed Drive (ASD). Severe voltage unbalance can force three-phase rectifiers into almost single-phase operation, which...... degrades the grid power quality and also imposes a significant negative impact on the ASD system. This major power quality issue affecting the conventional rectifiers can be attenuated by controlling the DC-link current based on an Electronic Inductor (EI) technique. The purpose of this digest...

  16. Distributed Energy Systems: Security Implications of the Grid of the Future

    Energy Technology Data Exchange (ETDEWEB)

    Stamber, Kevin L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kelic, Andjelka [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Taylor, Robert A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Henry, Jordan M [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Stamp, Jason E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-01-01

    Distributed Energy Resources (DER) are being added to the nation's electric grid, and as penetration of these resources increases, they have the potential to displace or offset large-scale, capital-intensive, centralized generation. Integration of DER into operation of the traditional electric grid requires automated operational control and communication of DER elements, from system measurement to control hardware and software, in conjunction with a utility's existing automated and human-directed control of other portions of the system. Implementation of DER technologies suggests a number of gaps from both a security and a policy perspective. This page intentionally left blank.

  17. Modelling and control of hybrid renewable energy system connected to AC grid

    Directory of Open Access Journals (Sweden)

    Sami Younsi

    2011-12-01

    Full Text Available This paper discusses the development of new control and supervision method for the optimum operation of hybrid renewable energy system (HRES connected to AC grid. The hybrid system consists of wind generator (WG, diesel generator (DG, and flywheel energy storage system (FESS. These subsystems are based on permanent magnet synchronous machines (PMSM which are controlled by sliding mode control. A supervisor control is designed to determine the energy transfer type of flywheel energy storage system (charging / discharging / no transfer energy, to take decision on diesel generators ON/OFF status, and to determine the reference powers for these two subsystems. The supervisor inputs are the power requested by AC grid, the power generated by wind generator, and the energy stored in flywheel. The objectives of the control and supervision for hybrid renewable energy system are to satisfy the power requested by AC grid, to manage the energy transfer between hybrid system and AC grid, to optimize the use of wind energy, and to reduce fuel of diesel generator. The system is simulated with Matlab – Simulink software and it gave good results.

  18. Advanced Ground Systems Maintenance Physics Models For Diagnostics Project

    Science.gov (United States)

    Perotti, Jose M.

    2015-01-01

    The project will use high-fidelity physics models and simulations to simulate real-time operations of cryogenic and systems and calculate the status/health of the systems. The project enables the delivery of system health advisories to ground system operators. The capability will also be used to conduct planning and analysis of cryogenic system operations. This project will develop and implement high-fidelity physics-based modeling techniques tosimulate the real-time operation of cryogenics and other fluids systems and, when compared to thereal-time operation of the actual systems, provide assessment of their state. Physics-modelcalculated measurements (called “pseudo-sensors”) will be compared to the system real-timedata. Comparison results will be utilized to provide systems operators with enhanced monitoring ofsystems' health and status, identify off-nominal trends and diagnose system/component failures.This capability can also be used to conduct planning and analysis of cryogenics and other fluidsystems designs. This capability will be interfaced with the ground operations command andcontrol system as a part of the Advanced Ground Systems Maintenance (AGSM) project to helpassure system availability and mission success. The initial capability will be developed for theLiquid Oxygen (LO2) ground loading systems.

  19. The Spartan attitude control system - Ground support computer

    Science.gov (United States)

    Schnurr, R. G., Jr.

    1986-01-01

    The Spartan Attitude Control System (ACS) contains a command and control computer. This computer is optimized for the activities of the flight and contains very little human interface hardware and software. The computer system provides the technicians testing of Spartan ACS with a convenient command-oriented interface to the flight ACS computer. The system also decodes and time tags data automatically sent out by the flight computer as key events occur. The duration and magnitude of all system maneuvers is also derived and displayed by this system. The Ground Support Computer is also the primary Ground Support Equipment for the flight sequencer which controls all payload maneuvers, and long term program timing.

  20. Enhanced Control of a DFIG-Based Wind-Power Generation System With Series Grid-Side Converter Under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Yao, Jun; Li, Hui; Chen, Zhe

    2013-01-01

    This paper presents an enhanced control method for a doubly fed induction generator (DFIG)-based wind-power generation system with series grid-side converter (SGSC) under unbalanced grid voltage conditions. The behaviors of the DFIG system with SGSC during network unbalance are described. By inje......This paper presents an enhanced control method for a doubly fed induction generator (DFIG)-based wind-power generation system with series grid-side converter (SGSC) under unbalanced grid voltage conditions. The behaviors of the DFIG system with SGSC during network unbalance are described....... By injecting a series control voltage generated from the SGSC to balance the stator voltage, the adverse effects of voltage unbalance upon the DFIG, such as stator and rotor current unbalances, electromagnetic torque, and power pulsations, can be removed, and then the conventional vector control strategy...... for the rotor-side converter remains in full force under unbalanced conditions. Meanwhile, three control targets for the parallel grid-side converter (PGSC) are identified, including eliminating the oscillations in the total active power or reactive power, or eliminating negative-sequence current injected...

  1. Web interactive non intrusive load disaggregation system for active demand in smart grids

    Directory of Open Access Journals (Sweden)

    G.M. Tina

    2014-12-01

    Full Text Available A Smart Grid combines the use of traditional technology with innovative digital solutions, making the management of the electricity grid more flexible. It allows for monitoring, analysis, control and communication within the supply chain to improve efficiency, reduce the energy consumption and cost, and maximize the transparency and reliability of the energy supply chain. The optimization of energy consumption in Smart Grids is possible by using an innovative system based on Non Intrusive Appliance Load Monitoring (NIALM algorithms, in which individual appliance power consumption information is disaggregated from single-point measurements, that provide a feedback in such a way to make energy more visible and more amenable to understanding and control. We contribute with an approach for monitoring consumption of electric power in households based on both a NILM algorithm, that uses a simple load signatures, and a web interactive systems that allows an active role played by users.

  2. Research on Experiment of Islanding Protection Device of Grid-connected Photovoltaic System Based on RTDS

    Science.gov (United States)

    Zhou, Ning; Yang, Jia; Cheng, Zheng; Chen, Bo; Su, Yong Chun; Shu, Zhan; Zou, Jin

    2017-06-01

    Solar photovoltaic power generation is the power generation using solar cell module converting sunlight into DC electric energy. In the paper an equivalent model of solar photovoltaic power generation system is built in RTDS. The main circuit structure of the two-stage PV grid-connected system consists of the DC-DC, DC-AC circuit. The MPPT (Maximum Power Point Tracking) control of the PV array is controlled by adjusting the duty ratio of the DC-DC circuit. The proposed control strategy of constant voltage/constant reactive power (V/Q) control is successfully implemented grid-connected control of the inverter when grid-connected operation. The closed-loop experiment of islanding protection device of photovoltaic power plant on RTDS, verifies the correctness of the simulation model, and the experimental verification can be applied to this type of device.

  3. Design of a nonlinear backstepping control strategy of grid interconnected wind power system based PMSG

    Science.gov (United States)

    Errami, Y.; Obbadi, A.; Sahnoun, S.; Benhmida, M.; Ouassaid, M.; Maaroufi, M.

    2016-07-01

    This paper presents nonlinear backstepping control for Wind Power Generation System (WPGS) based Permanent Magnet Synchronous Generator (PMSG) and connected to utility grid. The block diagram of the WPGS with PMSG and the grid side back-to-back converter is established with the dq frame of axes. This control scheme emphasises the regulation of the dc-link voltage and the control of the power factor at changing wind speed. Besides, in the proposed control strategy of WPGS, Maximum Power Point Tracking (MPPT) technique and pitch control are provided. The stability of the regulators is assured by employing Lyapunov analysis. The proposed control strategy for the system has been validated by MATLAB simulations under varying wind velocity and the grid fault condition. In addition, a comparison of simulation results based on the proposed Backstepping strategy and conventional Vector Control is provided.

  4. Systems for heat and cold from the ground. Proposal for a development program; System foer vaerme och kyla ur mark - Foerslag till utvecklingsprogram

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, Bengt; Gabrielsson, Anna; Fallsvik, Jan; Nilsson, Gunnel [Swedish Geotechnical Inst., Linkoeping (Sweden); Hellstroem, Goeran [Lund Inst. of Technology (Sweden). Dept. of Mathematical Physics

    2002-02-01

    Ground heat systems usually consist of a heat pump, with an evaporator connected to a heat carrier circuit of heat exchangers in the ground, and a condenser connected to the heat distribution system inside the building (radiators, fan convectors, floor heating etc). The heat pump's compressor is connected to the electricity grid. Similar systems without heat pumps are also used, where the excess heat from the building or process is exchanged with the cooler ground solely by circulation of the heat carrier fluid in the ground heat exchangers, so called 'Tree cooling'. The performance of ground heat systems depends on several factors. There is a continuous development of components and their interaction in heating/cooling systems, both in Sweden and abroad. Based on the current state of the art of ground heat systems and the national energy market it is possible to identify the development potential within many areas. In this report the development potentials for ground heat systems are presented in the following program areas: Combined heating/cooling systems with or without heat pumps and improvements of existing systems. Horizontal, compact and vertical ground heat exchangers, installation methods. Geological prerequisites and geotechnical impact of heating and/or cooling. Thermal capacity of all types of ground heat exchangers including moisture transport effects. Design specifications for different types of ground heat exchangers and ground conditions. Operation and maintenance. Environmental impact, e.g. of heat carrier fluids and local government environmental protection requirements. Economic optimization based on verified technical performance and cost figures.

  5. New control strategy for 2-stage grid-connected photovoltaic power system

    Energy Technology Data Exchange (ETDEWEB)

    Hamrouni, N.; Jraidi, M.; Cherif, A. [Laboratory of Electrical Systems, Engineering Faculty of Tunis, PB 37, 1002 Belvedere, Tunis (Tunisia)

    2008-10-15

    This work deals with the performances and responses of a grid-connected photovoltaic (PV) plant in normal and disturbed modes. The system is composed of a solar array, a dc-dc converter and a three-phase inverter connected to the utility grid. On the one hand a suitable control of the dc-dc converter is developed in order to extract the maximum amount of power from the PV generator. On the other hand an active and reactive power control approach (PQ) has been presented for the inverter. This method can provide a current with sinusoidal waveform and ensure a high power factor. Therefore, the grid interface inverter transfers the energy drawn from the PV into the grid by ensuring constant dc link voltage. Modeling and controlling were carried out using the informational graph of causality and the macroscopic energy representation methods. The simulation under MATLAB/SIMULINK and the experimental results show the control performance and dynamic behavior of grid-connected PV system in normal and disturbances modes. (author)

  6. Integrated Train Ground Radio Communication System Based TD-LTE

    Institute of Scientific and Technical Information of China (English)

    ZHAO Hongli; CAO Yuan; ZHU Li; XU Wei

    2016-01-01

    In existing metro systems, the train ground radio communication system for different applications are deployed independently. Investing and constructing the communication infrastructures repeatedly wastes substan-tial social resources, and it brings difficulties to maintain all these infrastructures. We present the communication Quality of service (QoS) requirement for different train ground radio applications. An integrated TD-LTE based train ground radio communication system for the metro system (LTE-M) is designed next. In order to test the LTE-M system performance, an indoor testing environment is set up. The channel simulator and programmable attenua-tors are used to simulate the real metro environment. Ex-tensive test results show that the designed LTE-M system performance satisfies metro communication requirements.

  7. Experimental evaluation of 8 kW grid-connected photovoltaic system in Egypt

    Directory of Open Access Journals (Sweden)

    A. Elkholy

    2016-09-01

    Full Text Available An experimental observation study of 8 kW grid-connected photovoltaic (PV system that is installed at Electronics Research Institute (ERI, Giza, Egypt (Latitude 30.04°N, Longitude 31.21°E, is presented. This study includes the quality of the electrical power generated and injected into the network. The considered system consists of 28 × 295 Wp multicrystalline PV modules, StecaGrid three-phase 8 kW grid-connected inverter and a Solar-Log 300 PM+ for data acquisition and remote monitoring. The power quality parameters at the inverter output side have been measured using CA8335 power quality analyzer. The system has been installed in August 2014 and generated 5.7 MWh till February 2015. The produced electricity by the system is injected directly into the grid without storage device. The purpose of this paper is to present and evaluate the measurements of the power quality parameters obtained from the PV site. Also, this paper presents a comprehensive evaluation of the performance of the system over a period of one week. The observation and analyses exploitation of the collected data can help to evaluate the performance of the PV system connected to the network.

  8. Pumpage for the transient ground-water flow model, Death Valley regional ground-water flow system, Nevada and California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This digital data set represents ground-water discharged from the Death Valley regional ground-water flow system (DVRFS) through pumped wells. Pumping from wells in...

  9. A Current-Forced Line-Commutated Inverter for Single-Phase Grid-Connected Photovoltaic Generation Systems

    OpenAIRE

    2015-01-01

    A simple power electronic interface based on the line-commutated inverter (LCI) has been developed in order to inject sinusoidal current to the grid for single-phase grid-connected photovoltaic (PV) energy generation systems. The proposed inverter facilitates controlling the injecting/grid current with a controllable power factor in contrast to the conventional LCI system. It is achieved that the total harmonic distortion (THD) of the injecting currents for the different firin...

  10. Size reduction of high- and low-moisture corn stalks by linear knife grid system

    Energy Technology Data Exchange (ETDEWEB)

    Womac, A.R. [University of Tennessee; Igathinathane, C. [Mississippi State University (MSU); Sokhansanj, Shahabaddine [ORNL; Narayan, S. [First American Scientific Co.

    2009-04-01

    High- and low-moisture corn stalks were tested using a linear knife grid size reduction device developed for first-stage size reduction. The device was used in conjunction with a universal test machine that quantified shearing stress and energy characteristics for forcing a bed of corn stalks through a grid of sharp knives. No published engineering performance data for corn stover with similar devices are available to optimize performance; however, commercial knife grid systems exist for forage size reduction. From the force displacement data, mean and maximum ultimate shear stresses, cumulative and peak mass-based cutting energies for corn stalks, and mean new surface area-based cutting energies were determined from 4 5 refill runs at two moisture contents (78.8% and 11.3% wet basis), three knife grid spacings (25.4, 50.8, and 101.6 mm), and three bed depths (50.8, 101.6, and 152.4 mm). In general, the results indicated that peak failure load, ultimate shear stress, and cutting energy values varied directly with bed depth and inversely with knife grid spacing. Mean separation analysis established that high- and low-moisture conditions and bed depths 101.6 mm did not differ significantly (P < 0.05) for ultimate stress and cutting energy values, but knife grid spacing were significantly different. Linear knife grid cutting energy requirements for both moisture conditions of corn stalks were much smaller than reported cutting energy requirements. Ultimate shear stress and cutting energy results of this research should aid the engineering design of commercial scale linear knife gird size reduction equipment for various biomass feedstocks.

  11. Size reduction of high- and low-moisture corn stalks by linear knife grid system

    Energy Technology Data Exchange (ETDEWEB)

    Igathinathane, C. [Agricultural and Biological Engineering Department, 130 Creelman Street, Mississippi State University, Mississippi State, Mississippi 39762 (United States); Womac, A.R. [Department of Biosystems Engineering and Soil Science, 2506 E. J. Chapman Drive, The University of Tennessee, Knoxville, Tennessee 37996 (United States); Sokhansanj, S. [Oak Ridge National Laboratory, Environmental Sciences Division, Oak Ridge, P. O. Box 2008, Tennessee 37831 (United States); Narayan, S. [First American Scientific Company, 100 Park Royal South West Vancouver, British Columbia, V7T 1A2 (Canada)

    2009-04-15

    High- and low-moisture corn stalks were tested using a linear knife grid size reduction device developed for first-stage size reduction. The device was used in conjunction with a universal test machine that quantified shearing stress and energy characteristics for forcing a bed of corn stalks through a grid of sharp knives. No published engineering performance data for corn stover with similar devices are available to optimize performance; however, commercial knife grid systems exist for forage size reduction. From the force-displacement data, mean and maximum ultimate shear stresses, cumulative and peak mass-based cutting energies for corn stalks, and mean new surface area-based cutting energies were determined from 4-5 refill runs at two moisture contents (78.8% and 11.3% wet basis), three knife grid spacings (25.4, 50.8, and 101.6 mm), and three bed depths (50.8, 101.6, and 152.4 mm). In general, the results indicated that peak failure load, ultimate shear stress, and cutting energy values varied directly with bed depth and inversely with knife grid spacing. Mean separation analysis established that high- and low-moisture conditions and bed depths {>=} 101.6 mm did not differ significantly (P < 0.05) for ultimate stress and cutting energy values, but knife grid spacing were significantly different. Linear knife grid cutting energy requirements for both moisture conditions of corn stalks were much smaller than reported cutting energy requirements. Ultimate shear stress and cutting energy results of this research should aid the engineering design of commercial scale linear knife gird size reduction equipment for various biomass feedstocks. (author)

  12. Real time hardware implementation of power converters for grid integration of distributed generation and STATCOM systems

    Science.gov (United States)

    Jaithwa, Ishan

    Deployment of smart grid technologies is accelerating. Smart grid enables bidirectional flows of energy and energy-related communications. The future electricity grid will look very different from today's power system. Large variable renewable energy sources will provide a greater portion of electricity, small DERs and energy storage systems will become more common, and utilities will operate many different kinds of energy efficiency. All of these changes will add complexity to the grid and require operators to be able to respond to fast dynamic changes to maintain system stability and security. This thesis investigates advanced control technology for grid integration of renewable energy sources and STATCOM systems by verifying them on real time hardware experiments using two different systems: d SPACE and OPAL RT. Three controls: conventional, direct vector control and the intelligent Neural network control were first simulated using Matlab to check the stability and safety of the system and were then implemented on real time hardware using the d SPACE and OPAL RT systems. The thesis then shows how dynamic-programming (DP) methods employed to train the neural networks are better than any other controllers where, an optimal control strategy is developed to ensure effective power delivery and to improve system stability. Through real time hardware implementation it is proved that the neural vector control approach produces the fastest response time, low overshoot, and, the best performance compared to the conventional standard vector control method and DCC vector control technique. Finally the entrepreneurial approach taken to drive the technologies from the lab to market via ORANGE ELECTRIC is discussed in brief.

  13. Modernizing Distribution System Restoration to Achieve Grid Resiliency Against Extreme Weather Events: An Integrated Solution

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chen; Wang, Jianhui; Ton, Dan

    2017-07-01

    Recent severe power outages caused by extreme weather hazards have highlighted the importance and urgency of improving the resilience of the electric power grid. As the distribution grids still remain vulnerable to natural disasters, the power industry has focused on methods of restoring distribution systems after disasters in an effective and quick manner. The current distribution system restoration practice for utilities is mainly based on predetermined priorities and tends to be inefficient and suboptimal, and the lack of situational awareness after the hazard significantly delays the restoration process. As a result, customers may experience an extended blackout, which causes large economic loss. On the other hand, the emerging advanced devices and technologies enabled through grid modernization efforts have the potential to improve the distribution system restoration strategy. However, utilizing these resources to aid the utilities in better distribution system restoration decision-making in response to extreme weather events is a challenging task. Therefore, this paper proposes an integrated solution: a distribution system restoration decision support tool designed by leveraging resources developed for grid modernization. We first review the current distribution restoration practice and discuss why it is inadequate in response to extreme weather events. Then we describe how the grid modernization efforts could benefit distribution system restoration, and we propose an integrated solution in the form of a decision support tool to achieve the goal. The advantages of the solution include improving situational awareness of the system damage status and facilitating survivability for customers. The paper provides a comprehensive review of how the existing methodologies in the literature could be leveraged to achieve the key advantages. The benefits of the developed system restoration decision support tool include the optimal and efficient allocation of repair

  14. Open System of Agile Ground Stations Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase I effort demonstrated, through actual development and tests with a spacecraft system, the technical and programmatic feasibility of developing, within the...

  15. Grid Connected Wind Energy Conversion System Using Three Phase Matrix Converter

    Directory of Open Access Journals (Sweden)

    R.A. Priya

    2015-01-01

    Full Text Available A variable speed Wind Energy Conversion System (WECS with Permanent Magnet Synchronous Generator (PMSG connected to grid through Matrix Converter (MC is proposed in this study. Necessity for increased demand in electrical energy paved way for use of renewable energy sources, one of which is abundant wind energy available in ample. Various Wind Energy Conversion systems have been proposed over the decades, of which various topologies had been projected, where complex topologies are being in existence. Permanent magnet synchronous generator has substantial advantages over conventional generators like less weight and volume and exemption for separate excitation with high precision. The conventional system involves two stage of conversion involving rectification followed by inversion being coupled by a DC link capacitor before fed to a grid, which decreases the efficiency of the system due to power quality issue. To overcome this matrix converter can be utilized to transfer the power from generation stage to the grid; there by an AC-AC converter can transfer power from generator to the grid. The proposed system is designed and tested in MATALB/Simulink environment and the results are effective.

  16. Grid-connected photovoltaic power systems: survey of inverter and related protection equipments

    Energy Technology Data Exchange (ETDEWEB)

    Ishikawa, T

    2002-12-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme reports on a survey made on inverter and related protection equipment. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. This report summarises the data obtained from survey of recent inverter technology and inverter protection equipment for grid interconnected PV systems. The results are based on the surveys using a questionnaire to identify the current status of grid-interconnection inverters. This report is to serve as a reference for those interested in installing grid-connected PV systems, electric utility company personnel, manufacturers and researchers. The results of the survey are presented and discussed. Technical and financial data is reviewed and two appendices provide details on the results obtained and those institutions involved in the survey.

  17. Developing Backward Chaining Algorithm of Inference Engine in Ternary Grid Expert System

    Directory of Open Access Journals (Sweden)

    Yuliadi Erdani

    2012-09-01

    Full Text Available The inference engine is one of main components of expert system that influences the performance of expert system. The task of inference engine is to give answers and reasons to users by inference the knowledge of expert system. Since the idea of ternary grid issued in 2004, there is only several developed method, technique or engine working on ternary grid knowledge model. The in 2010 developed inference engine is less efficient because it works based on iterative process. The in 2011 developed inference engine works statically and quite expensive to compute. In order to improve the previous inference methods, a new inference engine has been developed. It works based on backward chaining process in ternary grid expert system. This paper describes the development of inference engine of expert system that can work in ternary grid knowledge model. The strategy to inference knowledge uses backward chaining with recursive process. The design result is implemented in the form of software. The result of experiment shows that the inference process works properly, dynamically and more efficient to compute in comparison to the previous developed methods.

  18. Quantitative Analysis Method of Output Loss due to Restriction for Grid-connected PV Systems

    Science.gov (United States)

    Ueda, Yuzuru; Oozeki, Takashi; Kurokawa, Kosuke; Itou, Takamitsu; Kitamura, Kiyoyuki; Miyamoto, Yusuke; Yokota, Masaharu; Sugihara, Hiroyuki

    Voltage of power distribution line will be increased due to reverse power flow from grid-connected PV systems. In the case of high density grid connection, amount of voltage increasing will be higher than the stand-alone grid connection system. To prevent the over voltage of power distribution line, PV system's output will be restricted if the voltage of power distribution line is close to the upper limit of the control range. Because of this interaction, amount of output loss will be larger in high density case. This research developed a quantitative analysis method for PV systems output and losses to clarify the behavior of grid connected PV systems. All the measured data are classified into the loss factors using 1 minute average of 1 second data instead of typical 1 hour average. Operation point on the I-V curve is estimated to quantify the loss due to the output restriction using module temperature, array output voltage, array output current and solar irradiance. As a result, loss due to output restriction is successfully quantified and behavior of output restriction is clarified.

  19. Intelligent distributed voltage control system for smart grid application

    Energy Technology Data Exchange (ETDEWEB)

    Sajadi, Amirhossein [Warsaw Univ. of Technology (Poland); Ariatabar, Mitra [RWTH Aachen Univ. (Germany)

    2012-07-01

    Increasing penetration of the renewable energy source (RES) units in distribution networks particularly due to nonlinear and unpredictable nature of renewable units brings up new challenges in different aspects of electricity network, which leads to more complex power systems. Multi-agent system is consisting of agents which are capable to perceive environment that they are located in and to reacts with each other by communication infrastructure in order to achieve overall goals. In this paper an approach to control the voltage based on in the power distribution system is proposed and discussed. Therefore, a multi-agent system has been integrated with artificial intelligence to come up with fuzzy multi-agent based system. The proposed control scheme is deployed to a smart distribution system consisting distribution generation units, modelled in MATLAB/Simulink, to evaluate its effectiveness. The simulation results show how proposed system can regulate voltage in smart distribution feeders. (orig.)

  20. A Fuzzy ANP Model Integrated with Benefits, Opportunities, Costs, and Risks to Prioritize Intelligent Power Grid Systems

    Directory of Open Access Journals (Sweden)

    Hsing Hung Chen

    2013-01-01

    Full Text Available Although growth of renewable energy is envisaged, many concerns are critical like the ability to maintain the balance between demands and supply and the variability, noncontrollability, and flexibility of the sources. Then, what will be the future concerns about the main composition of intelligent power grid systems in the future? There is no such research tackled before. Thus, this paper first finds critical success criteria of intelligent power grid systems and then constructs a multiple criteria and decision making model to help in identifying the suitable trends under complex economic performance, environmental impacts, and rapid technological and marketing changes. After empirical demonstration, the paper summarizes that the most suitable composition of future intelligent power grid systems should be constituted by “DHT” P2P grid, “C&D workflow” P2P scheduling, “GARCM” trustworthy P2P grid, and “multipurpose” grid applications in the future.

  1. Design of a Glenn Research Center Solar Field Grid-Tied Photovoltaic Power System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2009-01-01

    The NASA Glenn Research Center (GRC) designed, developed, and installed, a 37.5 kW DC photovoltaic (PV) Solar Field in the GRC West Area in the 1970s for the purpose of testing PV panels for various space and terrestrial applications. The PV panels are arranged to provide a nominal 120 VDC. The GRC Solar Field has been extremely successful in meeting its mission. The PV panels and the supporting electrical systems are all near their end of life. GRC has designed a 72 kW DC grid-tied PV power system to replace the existing GRC West Area Solar Field. The 72 kW DC grid-tied PV power system will provide DC solar power for GRC PV testing applications, and provide AC facility power for all times that research power is not required. A grid-tied system is connected directly to the utility distribution grid. Facility power can be obtained from the utility system as normal. The PV system is synchronized with the utility system to provide power for the facility, and excess power is provided to the utility for use by all. The project transfers space technology to terrestrial use via nontraditional partners. GRC personnel glean valuable experience with PV power systems that are directly applicable to various space power systems, and provide valuable space program test data. PV power systems help to reduce harmful emissions and reduce the Nation s dependence on fossil fuels. Power generated by the PV system reduces the GRC utility demand, and the surplus power aids the community. Present global energy concerns reinforce the need for the development of alternative energy systems. Modern PV panels are readily available, reliable, efficient, and economical with a life expectancy of at least 25 years. Modern electronics has been the enabling technology behind grid-tied power systems, making them safe, reliable, efficient, and economical with a life expectancy of at least 25 years. The report concludes that the GRC West Area grid-tied PV power system design is viable for a reliable

  2. Space vehicle field unit and ground station system

    Energy Technology Data Exchange (ETDEWEB)

    Judd, Stephen; Dallmann, Nicholas; Delapp, Jerry; Proicou, Michael; Seitz, Daniel; Michel, John; Enemark, Donald

    2017-09-19

    A field unit and ground station may use commercial off-the-shelf (COTS) components and share a common architecture, where differences in functionality are governed by software. The field units and ground stations may be easy to deploy, relatively inexpensive, and be relatively easy to operate. A novel file system may be used where datagrams of a file may be stored across multiple drives and/or devices. The datagrams may be received out of order and reassembled at the receiving device.

  3. Space vehicle field unit and ground station system

    Science.gov (United States)

    Judd, Stephen; Dallmann, Nicholas; Delapp, Jerry; Proicou, Michael; Seitz, Daniel; Michel, John; Enemark, Donald

    2016-10-25

    A field unit and ground station may use commercial off-the-shelf (COTS) components and share a common architecture, where differences in functionality are governed by software. The field units and ground stations may be easy to deploy, relatively inexpensive, and be relatively easy to operate. A novel file system may be used where datagrams of a file may be stored across multiple drives and/or devices. The datagrams may be received out of order and reassembled at the receiving device.

  4. Marshall Space Flight Center Ground Systems Development and Integration

    Science.gov (United States)

    Wade, Gina

    2016-01-01

    Ground Systems Development and Integration performs a variety of tasks in support of the Mission Operations Laboratory (MOL) and other Center and Agency projects. These tasks include various systems engineering processes such as performing system requirements development, system architecture design, integration, verification and validation, software development, and sustaining engineering of mission operations systems that has evolved the Huntsville Operations Support Center (HOSC) into a leader in remote operations for current and future NASA space projects. The group is also responsible for developing and managing telemetry and command configuration and calibration databases. Personnel are responsible for maintaining and enhancing their disciplinary skills in the areas of project management, software engineering, software development, software process improvement, telecommunications, networking, and systems management. Domain expertise in the ground systems area is also maintained and includes detailed proficiency in the areas of real-time telemetry systems, command systems, voice, video, data networks, and mission planning systems.

  5. System Performance Modelling of a Grid-Connected Photovoltaic System in UiTM, Malaysia

    Directory of Open Access Journals (Sweden)

    Nurmalessa Muhammad

    2017-08-01

    Full Text Available This paper presents the prediction of grid-connected photovoltaic (GCPV system installed at Green Energy Research Center, Universiti Teknologi MARA, Shah Alam, Malaysia located at latitude of 2 °N 101°E. By using Mathematical approach and climate variations of Malaysia such as module temperature and solar irradiance, the prediction of power systems performance parameters were analyzed. The parameter of the study is limited to 26 consecutive days with filter data of 80W/m2 irradiance. This study conducted by using monocrystalline and polycrystalline solar cell technologies. The actual and the predicted data measurement of these solar cell technologies were analyzed. The empirical models were compared according to the coefficient of determination (R2 and percentage error.  MathCAD software was used in order to calculate the prediction and detail analysis of electrical parameters. Finally, the results show a good accuracy between actual and prediction data.

  6. New gridded database of clear-sky solar radiation derived from ground-based observations over Europe

    Science.gov (United States)

    Bartok, Blanka; Wild, Martin; Sanchez-Lorenzo, Arturo; Hakuba, Maria Z.

    2017-04-01

    Since aerosols modify the entire energy balance of the climate system through different processes, assessments regarding aerosol multiannual variability are highly required by the climate modelling community. Because of the scarcity of long-term direct aerosol measurements, the retrieval of aerosol data/information from other type of observations or satellite measurements are very relevant. One approach frequently used in the literature is analyze of the clear-sky solar radiation which offer a better overview of changes in aerosol content. In the study first two empirical methods are elaborated in order to separate clear-sky situations from observed values of surface solar radiation available at the World Radiation Data Center (WRDC), St. Petersburg. The daily data has been checked for temporal homogeneity by applying the MASH method (Szentimrey, 2003). In the first approach, clear sky situations are detected based on clearness index, namely the ratio of the surface solar radiation to the extraterrestrial solar irradiation. In the second approach the observed values of surface solar radiation are compared to the climatology of clear-sky surface solar radiation calculated by the MAGIC radiation code (Muller et al. 2009). In both approaches the clear-sky radiation values highly depend on the applied thresholds. In order to eliminate this methodological error a verification of clear-sky detection is envisaged through a comparison with the values obtained by a high time resolution clear-sky detection and interpolation algorithm (Long and Ackermann, 2000) making use of the high quality data from the Baseline Surface Radiation Network (BSRN). As the consequences clear-sky data series are obtained for 118 European meteorological stations. Next a first attempt has been done in order to interpolate the point-wise clear-sky radiation data by applying the MISH (Meteorological Interpolation based on Surface Homogenized Data Basis) method for the spatial interpolation of

  7. Optimal Power Scheduling for a Grid-Connected Hybrid PV-Wind-Battery Microgrid System

    DEFF Research Database (Denmark)

    Hernández, Adriana Carolina Luna; Aldana, Nelson Leonardo Diaz; Savaghebi, Mehdi

    2016-01-01

    In this paper, a lineal mathematical model is proposed to schedule optimally the power references of the distributed energy resources in a grid-connected hybrid PVwind-battery microgrid. The optimization of the short term scheduling problem is addressed through a mixed-integer linear programming...... mathematical model, wherein the cost of energy purchased from the main grid is minimized and profits for selling energy generated by photovoltaic arrays are maximized by considering both physical constraints and requirements for a feasible deployment in the real system. The optimization model is tested...

  8. A Novel Flying Capacitor Transformerless Inverter for Single-Phase Grid Connected Solar Photovoltaic System

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede

    2016-01-01

    This paper proposes a new single-phase flying capacitor transformerless PV inverter for grid-connected photovoltaic (PV) systems. The neutral of the grid can be directly connected to the negative terminal of the source (PV). It consists of four power switches, one diode, one capacitor and a small...... and some topologies, which requires two times of the peak ac-voltage magnitude) and, (5) the flying capacitor charges every switching cycle, which reduces the size of the required capacitor with switching frequency. In addition, industry standard half bridge module can be used in the new inverter without...

  9. Islanding detection technique using wavelet energy in grid-connected PV system

    Science.gov (United States)

    Kim, Il Song

    2016-08-01

    This paper proposes a new islanding detection method using wavelet energy in a grid-connected photovoltaic system. The method detects spectral changes in the higher-frequency components of the point of common coupling voltage and obtains wavelet coefficients by multilevel wavelet analysis. The autocorrelation of the wavelet coefficients can clearly identify islanding detection, even in the variations of the grid voltage harmonics during normal operating conditions. The advantage of the proposed method is that it can detect islanding condition the conventional under voltage/over voltage/under frequency/over frequency methods fail to detect. The theoretical method to obtain wavelet energies is evolved and verified by the experimental result.

  10. Stochastic Impact Assessment of the Heating and Transportation Systems Electrification on LV grids

    DEFF Research Database (Denmark)

    Mendaza, Iker Diaz de Cerio; Bak-Jensen, Birgitte; Chen, Zhe

    2014-01-01

    loads in networks which were not designed for them. In low voltage grids especially, depending on the system penetration grade and the way they are disposed produces a completely different reaction of the network. This paper introduces a methodology for stochastically evaluating the impact caused....... As a case study, a typical Danish low voltage grid is considered. The results obtained, using DIgSILENT PowerFactory, show that sometimes the hosting capability of these networks may be poor for the integration levels expected....

  11. Performance Analysis of a Grid connected Wind Energy system

    Directory of Open Access Journals (Sweden)

    Manju Khare

    2016-07-01

    Full Text Available This paper is concerned with the study of a small wind generation system used for battery charging. A topology that aims at the exploitation of maximum energy from the generator, generated at low speed is proposed. The characteristics of the wind turbine and the generator are discussed, providing the overview of the system modeling. Simulation tests of the system are obtained using MATLAB/SIMULINK. We adopt compact permanent magnet type synchronous generator, which doesn’t need exciting current, and step- up /down buck-boost chopper to wind power generating system of a few kW output with rotor speed sensor. In addition, we employ rectifier circuit using Diode Bridge instead of AC-DC converter with PWM method and a battery charging system. Using these methods we achieve a simple wind power generation system

  12. FIFE-Jobsub: a grid submission system for intensity frontier experiments at Fermilab

    Science.gov (United States)

    Box, Dennis

    2014-06-01

    The Fermilab Intensity Frontier Experiments use an integrated submission system known as FIFE-jobsub, part of the FIFE (Fabric for Frontier Experiments) initiative, to submit batch jobs to the Open Science Grid. FIFE-jobsub eases the burden on experimenters by integrating data transfer and site selection details in an easy to use and well-documented format. FIFE-jobsub automates tedious details of maintaining grid proxies for the lifetime of the grid job. Data transfer is handled using the Intensity Frontier Data Handling Client (IFDHC) [1] tool suite, which facilitates selecting the appropriate data transfer method from many possibilities while protecting shared resources from overload. Chaining of job dependencies into Directed Acyclic Graphs (Condor DAGS) is well supported and made easier through the use of input flags and parameters.

  13. Evaluation of security availability of data components for a renewable energy micro Smart Grid system

    Science.gov (United States)

    Aguilera Zambrano, Leonel

    In this thesis, we study the development and security testing of photovoltaic data collection system. With the introduction of the smart grid concept, a lot of research has been done on the communication aspect of energy production and distribution throughout the power network. For Smart Grid, Internet is used as the communication medium for specific required services and for data collection. Despite all the advantages of the Smart Grid infrastructure, there is also some security concern regarding the vulnerabilities associated with internet access. In this thesis, we consider security testing of the two most popular and globally deployed web server platforms Apache running on Red Had Linux 5 and IIS on Windows Server 2008, and their performance under Distributed Denial of Service Attacks. Furthermore we stress test the data collection services provided by MySQL running on both Windows and Linux Servers when it is also under DDoS attacks.

  14. Implementation of fuzzy-sliding mode based control of a grid connected photovoltaic system.

    Science.gov (United States)

    Menadi, Abdelkrim; Abdeddaim, Sabrina; Ghamri, Ahmed; Betka, Achour

    2015-09-01

    The present work describes an optimal operation of a small scale photovoltaic system connected to a micro-grid, based on both sliding mode and fuzzy logic control. Real time implementation is done through a dSPACE 1104 single board, controlling a boost chopper on the PV array side and a voltage source inverter (VSI) on the grid side. The sliding mode controller tracks permanently the maximum power of the PV array regardless of atmospheric condition variations, while The fuzzy logic controller (FLC) regulates the DC-link voltage, and ensures via current control of the VSI a quasi-total transit of the extracted PV power to the grid under a unity power factor operation. Simulation results, carried out via Matlab-Simulink package were approved through experiment, showing the effectiveness of the proposed control techniques.

  15. Fault Ride-Through of a Grid-connected Photovoltaic System with Quasi Z Source Inverter

    DEFF Research Database (Denmark)

    Al-Durra, Ahmed; Fayyad, Yara; Muyeen, S.M.

    2016-01-01

    This article presents fault ride-through schemes for a three-phase quasi Z source single-stage photovoltaic (PV) inverter that is connected to the grid after the distribution network. The quasi Z source inverter employs a unique LC network to couple the inverter main circuit to the input of the PV...... panel. By controlling the shoot-through duty cycle, the quasi Z source inverter can theoretically produce any desired output AC voltage, even greater than the line voltage. Three different control strategies to improve the low-voltage ride-through capability are proposed when there is voltage sag from...... the grid side so that the grid fault ride-through requirements can be fulfilled. Scheme A involves control modification in the system; Schemes B and C involve hardware modification in the circuit topology by adding a chopper circuit across the DC link in Scheme B and across the quasi Z source inverter...

  16. Probability-Based Software for Grid Optimization: Improved Power System Operations Using Advanced Stochastic Optimization

    Energy Technology Data Exchange (ETDEWEB)

    None

    2012-02-24

    GENI Project: Sandia National Laboratories is working with several commercial and university partners to develop software for market management systems (MMSs) that enable greater use of renewable energy sources throughout the grid. MMSs are used to securely and optimally determine which energy resources should be used to service energy demand across the country. Contributions of electricity to the grid from renewable energy sources such as wind and solar are intermittent, introducing complications for MMSs, which have trouble accommodating the multiple sources of price and supply uncertainties associated with bringing these new types of energy into the grid. Sandia’s software will bring a new, probability-based formulation to account for these uncertainties. By factoring in various probability scenarios for electricity production from renewable energy sources in real time, Sandia’s formula can reduce the risk of inefficient electricity transmission, save ratepayers money, conserve power, and support the future use of renewable energy.

  17. Operation and control of a DC-grid offshore wind farm under DC transmission system faults

    DEFF Research Database (Denmark)

    Deng, Fujin; Chen, Zhe

    2013-01-01

    So far, all existing offshore wind farms have an ac collection system, and the collected power in the offshore wind farm is sent to an onshore ac grid through high-voltage ac (HVAC) or DC (HVDC) transmission lines. However, future of fshore wind farms may use dc also for power collection. Consequ...

  18. 6th Annual Earth System Grid Federation Face to Face Conference Report

    Energy Technology Data Exchange (ETDEWEB)

    Williams, D. N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-03-06

    The Sixth Annual Face-to-Face (F2F) Conference of the Earth System Grid Federation (ESGF), a global consortium of international government agencies, institutions, and companies dedicated to the creation, management, analysis, and distribution of extreme-scale scientific data, was held December 5–9, 2016, in Washington, D.C.

  19. Dynamics of voltage source converter in a grid connected solar photovoltaic system

    DEFF Research Database (Denmark)

    Haribabu, Divyanagalakshmi; Vangari, Adithya; Sakamuri, Jayachandra N.

    2015-01-01

    This paper emphasises the modelling and control of a voltage source converter (VSC) for three phase grid connected PV system. The transfer functions for inner current control and outer DC link voltage control for VSC are derived. The controllers for VSC are designed based on PI and K factor contr...... conditions. The effectiveness of the proposed controller is illustrated by evaluating the response of PV system for power system voltage sag and swell conditions as well as grid faults.......This paper emphasises the modelling and control of a voltage source converter (VSC) for three phase grid connected PV system. The transfer functions for inner current control and outer DC link voltage control for VSC are derived. The controllers for VSC are designed based on PI and K factor control...... methods and the performance of VSC using both the methods are presented with the simulations performed using PSCAD/EMTDC. The design of LC filter to meet the specified THD requirement for grid connected VSC is presented and the corresponding harmonic analysis is performed for different solar radiation...

  20. A Combined Two-Method MPPT Control Scheme for Grid-Connected Photovoltaic Systems

    DEFF Research Database (Denmark)

    Dorofte, Christinel; Borup, Uffe; Blaabjerg, Frede

    2005-01-01

    In order to increase the output efficiency of a grid-connected photovoltaic (PV) system it is important to have an efficient Maximum Power Point Tracker (MPPT). In the case of low irradiation, the Perturb and Observe (PO) and Incremental Conductance (IC) methods have a poor efficiency, because of...

  1. Fast solution of nonsymmetric linear systems on Grid computers using parallel variants of IDR(s)

    NARCIS (Netherlands)

    Collignon, T.P.; Van Gijzen, M.B.

    IDR(s) is a family of fast algorithms for iteratively solving large nonsymmetric linear systems [14]. With cluster computing and in particular with Grid computing, the inner product is a bottleneck operation. In this paper, three techniques are combined in order to alleviate this bottleneck. Firstly

  2. Smart grids in the colombian electric system: Current situation and potential opportunities

    Directory of Open Access Journals (Sweden)

    William Mauricio Giral Ramírez

    2017-07-01

    Full Text Available Context: This paper focuses on providing a functional analysis of smart grids, with the purpose of establishing a framework to identify the main characteristics of the current electric interconnection system in Colombia. It also names the positive incentives proposed by the Colombian government to support both research and development projects that implement non-conventional energy sources and promoting energy management based on efficiency. Method: An architecture model that describes the components interoperability of a smart grid is presented using a descriptive methodology. Results: The results include a list of the objectives established by the Colombian public and private entities related to energy development, specially focusing on the opportunities to provide some kind of artificial intelligence to the current electrical system. Conclusions: It is necessary for the Colombian energy system to supply the energy demand considering electrical safety, social equity, and the minimum environmental impact. These restrictions impose new challenges for the energy system itself: From a technical point of view, the traditional electrical grid must be outfitted with the characteristics of a smart grid, and from a legal perspective, it is essential to generate a clear regulatory framework that promotes the development of this type of technology.

  3. Method for detecting an open-switch fault in a grid-connected NPC inverter system

    DEFF Research Database (Denmark)

    Choi, Ui-Min; Jeong, Hae-Gwang; Lee, Kyo-Beum;

    2012-01-01

    This paper proposes a fault-detection method for an open-switch fault in the switches of grid-connected neutral-point-clamped inverter systems. The proposed method can not only detect the fault condition but also identify the location of the faulty switch. In the proposed method, which is designed...

  4. Fast solution of nonsymmetric linear systems on Grid computers using parallel variants of IDR(s)

    NARCIS (Netherlands)

    Collignon, T.P.; Van Gijzen, M.B.

    IDR(s) is a family of fast algorithms for iteratively solving large nonsymmetric linear systems [14]. With cluster computing and in particular with Grid computing, the inner product is a bottleneck operation. In this paper, three techniques are combined in order to alleviate this bottleneck. Firstly

  5. Analysis of Three-Phase Rectifier Systems with Controlled DC-Link Current Under Unbalanced Grids

    DEFF Research Database (Denmark)

    Kumar, Dinesh; Davari, Pooya; Zare, Firuz

    2017-01-01

    Voltage unbalance is the most common disturbance in distribution networks, which give undesirable effects on many grid connected power electronics systems including Adjustable Speed Drive (ASD). Severe voltage unbalance can force three-phase rectifiers into almost single-phase operation, which de...

  6. Using System Dynamics to Define, Study, and Implement Smart Control Strategies on the Electric Power Grid

    Energy Technology Data Exchange (ETDEWEB)

    Lyle G. Roybal; Robert F Jeffers

    2013-07-01

    The United States electric power grid is the most complex and expansive control system in the world. Local generation control occurs at individual units based on response time and unit economics, larger regional control coordinates unit response to error conditions, and high level large-area regional control is ultimately administered by a network of humans guided by economic and resiliency related factors. Under normal operating conditions, the grid is a relatively slow moving entity that exhibits high inertia to outside stimuli, and behaves along repeatable diurnal and seasonal patterns. However, that paradigm is quickly changing because of the increasing implementation of renewable generation sources. Renewable generators by nature cannot be tightly controlled or scheduled. They appear like a negative load to the system with all of the variability associated with load on a larger scale. Also, grid-reactive loads (i.e. smart devices) can alter their consumption based on price or demand rules adding more variability to system behavior. This paper demonstrates how a systems dynamic modeling approach capable of operating over multiple time scales, can provide valuable insight into developing new “smart-grid” control strategies and devices needed to accommodate renewable generation and regulate the frequency of the grid.

  7. Vehicle-to-Grid Systems for Frequency Regulation in an Islanded Danish Distribution Network

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2010-01-01

    Electric vehicles (EVs) have gained significant attention in the recent years due to their prospects in reducing greenhouse gas emissions benefitting the transportation sector directly and the electricity sector indirectly. Vehicle-to-grid (V2G) systems using the battery storages of electric...... vehicles could provide power system ancillary services in the form of power balancing reserves to support the large-scale integration of variable renewable energy sources like wind power. This paper investigates the dynamic frequency response of an islanded Danish distribution system operation with large...... amount of wind power supported by the Vehicle-to-grid systems. The power system simulations are analysed for scenarios with 48% and 65% of wind power penetration. The simulation results show that the V2G systems provide a faster and stable frequency control than the conventional generation units. V2G...

  8. A New GPS-based Digital Protection System for Smart Grids in Loop Structure

    Directory of Open Access Journals (Sweden)

    X. Liu

    2014-12-01

    Full Text Available This paper presents a new digital protection system to solve the protection challenges in future smart grids, i.e., fast protection and fault isolation in a loop-structured system with limited magnitude of fault current. The new system combines two protection algorithms, i.e., a differential protection as the primary algorithm and an overcurrent protection as the backup one. The new system uses real-time Ethernet and digital data acquisition techniques to overcome the restriction on data transmission over large grids. The current measurements at different locations are time-synchronized by GPS clocks, and then transmitted to a central computer via the Ethernet. As opposed to digital relays which often contain PMU functionality nowadays, this approach uses time stamps on the instantaneous current values. We build a prototype of the new system on a test-bed. The results from simulations and experiments have demonstrated that the protection system achieves fast and accurate protection.

  9. Development of a Hydrogen Energy System as a Grid Frequency Management Tool

    Energy Technology Data Exchange (ETDEWEB)

    Ewan, Mitch [Univ. of Hawaii, Honolulu, HI (United States); Rocheleau, Richard [Univ. of Hawaii, Honolulu, HI (United States); Swider-Lyons, Karen [U.S. Naval Research Lab., Washington, DC (United States); Virji, Meheboob [GRandalytics, Honolulu, HI (United States); Randolph, Guenter [Hydrogen Renewable Energy System Analysis, Pickering, ON (Canada)

    2016-07-15

    The Hawai‘i Natural Energy Institute (HNEI) is conducting research to assess the technical potential of using an electrolyzer-based hydrogen (H2) production and storage system as a grid demand response tool using battery data from a 200 MW grid to show the kind of response required. The hydrogen produced by the electrolyzer is used for transportation. A 65 kg/day hydrogen energy system (HES) consisting of a PEM electrolyzer, 35 bar buffer tank, 450 bar compressor, and associated chiller systems was purchased and installed at the Hawaii Natural Energy Laboratory Hawaii Authority (NELHA) to demonstrate long-term durability of the electrolyzer under cyclic operation required for frequency regulation on an island grid system. The excess hydrogen was stored for use by three fuel-cell buses to be operated at Hawai‘i Volcanoes National Park (HAVO) and by the County of Hawai‘i Mass Transit Agency (MTA). This paper describes the site selection and equipment commissioning, plus a comprehensive test plan that was developed to characterize the performance and durability of the electrolyzer under dynamic load conditions. The controls were modified for the operating envelope and dynamic limits of the electrolyzer. While the data showed these modifications significantly improved the system response time, it is not fast enough to match a BESS response time for grid frequency management. The electrolyzer can only be used for slower acting changes (1 to 0.5 Hz). A potential solution is to design an electrolyzer/BESS hybrid system and develop a modeling program to find the optimum mix of battery and electrolyzer to provide the maximum grid regulation services at minimum cost.

  10. Photovoltaic system design in grid-connected applications

    Science.gov (United States)

    Jones, G. J.

    The design of photovoltaic (PV) systems was traditionally done from the owner's viewpoint. This does not present a problem in central station applications but may result in misleading guidance for distributed system configurations. The results of the traditional design approach are contrasted with those obtained when the utility and application are viewed as a whole. The typical design assumes that on-site energy use must be maximized leading to a synergism between on-site loads and design optimization. This is shown to be a false requirement, resulting from considering only the system owner. When the system and utility are viewed together, the value of PV energy is found to be independent of the point of consumption. Load management, conservation, and passive solar design may affect energy use but have no impact on PV energy value. Furthermore, the value of PV energy is essentially the same for all systems, whether distributed or centralized.

  11. Reduced order modeling of grid-connected photovoltaic inverter systems

    Science.gov (United States)

    Wasynczuk, O.; Krause, P. C.; Anwah, N. A.

    1988-04-01

    This report summarizes the development of reduced order models of three-phase, line- and self-commutated inverter systems. This work was performed as part of the National Photovoltaics Program within the United States Department of Energy and was supervised by Sandia National Laboratories. The overall objective of the national program is to promote the development of low cost, reliable terrestrial photovoltaic systems for widespread use in residential, commercial and utility applications. The purpose of the effort reported herein is to provide reduced order models of three-phase, line- and self-commutated PV systems suitable for implementation into transient stability programs, which are commonly used to predict the stability characteristics of large-scale power systems. The accuracy of the reduced models is verified by comparing the response characteristics predicted therefrom with the response established using highly detailed PV system models in which the inverter switching is represented in detail.

  12. Equivalence of the Symbol Grounding and Quantum System Identification Problems

    Directory of Open Access Journals (Sweden)

    Chris Fields

    2014-02-01

    Full Text Available The symbol grounding problem is the problem of specifying a semantics for the representations employed by a physical symbol system in a way that is neither circular nor regressive. The quantum system identification problem is the problem of relating observational outcomes to specific collections of physical degrees of freedom, i.e., to specific Hilbert spaces. It is shown that with reasonable physical assumptions these problems are equivalent. As the quantum system identification problem is demonstrably unsolvable by finite means, the symbol grounding problem is similarly unsolvable.

  13. A Quarter Active Suspension System Based Ground-Hook Controller

    Directory of Open Access Journals (Sweden)

    Turnip Arjon

    2016-01-01

    Full Text Available An alternative design technique for active suspension system of vehicle using a developved ground-hook damping system as a reference is proposed. The controller parameters are determined using Lyapunov method and can be tuned to precisely achieve the type of desired response which given by reference model. The simulation result show that the designed active suspension system based ground-hook reference model is able to significantly improve the ride comfort and the road holding compared with semi-active suspension.

  14. Co-Simulation of Detailed Whole Building with the Power System to Study Smart Grid Applications

    Energy Technology Data Exchange (ETDEWEB)

    Makhmalbaf, Atefe; Fuller, Jason C.; Srivastava, Viraj; Ciraci, Selim; Daily, Jeffrey A.

    2014-12-24

    Modernization of the power system in a way that ensures a sustainable energy system is arguably one of the most pressing concerns of our time. Buildings are important components in the power system. First, they are the main consumers of electricity and secondly, they do not have constant energy demand. Conventionally, electricity has been difficult to store and should be consumed as it is generated. Therefore, maintaining the demand and supply is critical in the power system. However, to reduce the complexity of power models, buildings (i.e., end-use loads) are traditionally modeled and represented as aggregated “dumb” nodes in the power system. This means we lack effective detailed whole building energy models that can support requirements and emerging technologies of the smart power grid. To gain greater insight into the relationship between building energy demand and power system performance, it is important to constitute a co-simulation framework to support detailed building energy modeling and simulation within the power system to study capabilities promised by the modern power grid. This paper discusses ongoing work at Pacific Northwest National Laboratory and presents underlying tools and framework needed to enable co-simulation of building, building energy systems and their control in the power system to study applications such as demand response, grid-based HVAC control, and deployment of buildings for ancillary services. The optimal goal is to develop an integrated modeling and simulation platform that is flexible, reusable, and scalable. Results of this work will contribute to future building and power system studies, especially those related to the integrated ‘smart grid’. Results are also expected to advance power resiliency and local (micro) scale grid studies where several building and renewable energy systems transact energy directly. This paper also reviews some applications that can be supported and studied using the framework introduced

  15. Sensitivity of the dispatch strategy in designing grid integrated hybrid energy systems

    OpenAIRE

    Perera, Amarasinghage Tharindu Dasun; Mauree, Dasaraden; Scartezzini, Jean-Louis; Nik, Vahid M.

    2016-01-01

    Integrating renewable energy technologies based on solar PV (SPV) and wind energy in the energy system is challenging due to time dependence of the energy potential for these energy sources. Grid integrated hybrid energy systems combining SPV panels, wind turbines, battery bank and internal combustion generators (ICG) can be used in this regard specially for distributed generation. Energy-economic dispatch strategy plays a vital role in managing the energy flow of the system. However, it is d...

  16. Automatic knowledge extraction in sequencing analysis with multiagent system and grid computing.

    Science.gov (United States)

    González, Roberto; Zato, Carolina; Benito, Rocío; Bajo, Javier; Hernández, Jesús M; De Paz, Juan F; Vera, Vicente; Corchado, Juan M

    2012-07-24

    Advances in bioinformatics have contributed towards a significant increase in available information. Information analysis requires the use of distributed computing systems to best engage the process of data analysis. This study proposes a multiagent system that incorporates grid technology to facilitate distributed data analysis by dynamically incorporating the roles associated to each specific case study. The system was applied to genetic sequencing data to extract relevant information about insertions, deletions or polymorphisms.

  17. Optimum Design Of Grid Connected Photovoltaic System Using Concentrators

    Directory of Open Access Journals (Sweden)

    Eng. Mohammed Fawzy

    2015-08-01

    Full Text Available Abstract Due to the increasing demand of electrical energy in Egypt and also in many neighboring countries around the world the main problem facing electrical energy production using classical methods such steam power stations is the depletion of fossil fuels. The gap between the electrical energy demand and the continuous increase on the fossil fuel cost make the problem of electricity generation more sophisticated. With the continuous decrease of the photovoltaic PV technologies cost it doesnt make sense neglecting the importance of electricity production using solar photovoltaic PV especially that the annual average daily energy received is about 6 kamp12310whmamp123112day in Cairo Egypt 30N.In this work a detailed simulation model including photovoltaic PV module characteristics and climatic conditions of Cairo Egypt is developed. The model compares fixed PV systems electrical energy output with photovoltaic PV system using concentrators and double axis tracker systems. The comparison includes the energy generated area required as well as the cost per kwh generated. The optimality criterion is the cost per kwh generated. The system that gives the minimum cost per kwh is the optimum system. To verify the developed model the simulation results of fixed PV modules and CPV using tracking system obtained by the model are compared with practical measurements of 40KW peak station erected in Cairo Egypt 30N.Very good agreement between measured values and results obtained from detailed simulation model. For fixed PV system the detailed economic analysis showed that it gives minimum cost perkwh generated Comparisons among these systems are presented. For Cairo results showed that a cost of about 6 to 9 US centskwh is attainable.

  18. Potential and cost-effectiveness of off-grid PV systems in Indonesia - An evaluation on a provincial level

    NARCIS (Netherlands)

    Veldhuis, A.J.; Reinders, A.H.M.E.

    2014-01-01

    In this study we estimate the potential of off-grid PV systems in Indonesia at a provincial level as a follow-up of a study on the potential of grid-connected PV systems in Indonesia which we executed in 2012 [1]. For this study we use an adapted methodology leading to cumulative numbers for the nom

  19. Maximum Power Point Tracking and Reactive Power Control of Single Stage Grid Connected Photovoltaic System

    Directory of Open Access Journals (Sweden)

    Y. Hoseynpoor

    2011-12-01

    Full Text Available Single-stage grid-connected Photovoltaic (PV systems have advantages such as simple topology, high efficiency, etc. However, since all the control objectives such as the maximum power point tracking (with the utility voltage, and harmonics reduction for output current need to be considered simultaneously, the complexity of the control scheme is much increased. In this paper a new type of grid connected photovoltaic (PV system with Maximum Power Point Tracking (MPPT and reactive power simultaneous control system is presented. System has two controlling loops to obtain the maximum power from the PV array and also has reactive power control (RPC. In order to decrease the complexity, cost and the number of converters, a singlestage PV system is applied. Using RPC and MPPT controllers, reference current is calculated and the current with low THD (<5% is injected to grid through Adaptive Predictive Current Control (APCC and current Controlled Voltage Source Inverter (CCVSI. The operation of the system is classified in to two day and night modes. In day mode MPPT and RPC control is accomplished and in night mode RPC control is accomplished like STATCOM operation. Reactive power control is continuously performed correctly with appropriate speed in two inductive and capacitive modes in both day and night modes. Thus, System Utilization Factor (SUF increases to 100% which is just 20% for common PV systems. Mathematical modeling of the system and the results of simulations in MATLAB/SIMULINK software are presented to investigate the correctness of the results.

  20. X-band uplink ground systems development

    Science.gov (United States)

    Hartop, R.; Johns, C.; Kolbly, R.

    1980-04-01

    The design of an X-band exciter and transmitter control system is presented. For the exciter design such aspects as the block diagram, expected oscillator frequency stability, effect of instability of the cables between the control room and the antenna, improvement in uplink stability obtained with the transmitter phase control loop, expected frequency stability of exciter references for the doppler extractors, expected performance of the X-band range modulator, and the frequency stability improvement to be obtained with temperature control of the hardware environment are covered.

  1. Evaluation of Harmonic Content from a Tap Transformer Based Grid Connection System for Wind Power

    Directory of Open Access Journals (Sweden)

    S. Apelfröjd

    2013-01-01

    Full Text Available Simulations done in MATLAB/Simulink together with experiments conducted at the Ångströms laboratory are used to evaluate and discuss the total harmonic distortion (THD and total demand distortion (TDD of a tap transformer based grid connection system. The grid connection topology can be used with different turbine and generator topologies and is here applied on a vertical axis wind turbine (VAWT with a permanent magnet synchronous generator (PMSG and its operational scheme. The full variable-speed wind conversion system consists of a diode rectifier, DC link, IGBT inverter, LCL-filter, and tap transformer. The full variable-speed operation is enabled by the use of the different step-up ratios of the tap transformer. In the laboratory study, a full experimental setup of the system was used, a clone of the on-site PMSG driven by a motor was used, and the grid was replaced with a resistive load. With a resistive load, grid harmonics and possible unbalances are removed. The results show a TDD and THD below 5% for the full operating range and harmonic values within the limits set up by IEEE-519. Furthermore, a change in tap, going to a lower step-up ratio, results in a reduction in both THD and TDD for the same output power.

  2. Development of 3-D Flow Analysis Code for Fuel Assembly using Unstructured Grid System

    Energy Technology Data Exchange (ETDEWEB)

    Myong, Hyon Kook; Kim, Jong Eun; Ahn, Jong Ki; Yang, Seung Yong [Kookmin Univ., Seoul (Korea, Republic of)

    2007-03-15

    The flow through a nuclear rod bundle with mixing vanes are very complex and required a suitable turbulence model to be predicted accurately. Final objective of this study is to develop a CFD code for fluid flow and heat transfer analysis in a nuclear fuel assembly using unstructured grid system. In order to develop a CFD code for fluid flow and heat transfer analysis in a nuclear fuel assembly using unstructured grid system, the following researches are made: - Development of numerical algorithm for CFD code's solver - Grid and geometric connectivity data - Development of software(PowerCFD code) for fluid flow and heat transfer analysis in a nuclear fuel assembly using unstructured grid system - Modulation of software(PowerCFD code) - Development of turbulence model - Development of analysis module of RANS/LES hybrid models - Analysis of turbulent flow and heat transfer - Basic study on LES analysis - Development of main frame on pre/post processors based on GUI - Algorithm for fully-developed flow.

  3. A Systems Approach to Analyzing Cyber-Physical Threats in the Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Almajali, Anas; Rice, Eric; Viswanathan, Arun; Tan, Kymie; Neuman, Clifford

    2016-10-01

    This paper presents a systems analysis approach to characterizing the risk of a Smart Grid to a load-drop attack. A characterization of the risk is necessary for the design of detection and remediation strategies to address the consequences of such attacks. Using concepts from systems health management and system engineering, this work (a) first identifies metrics that can be used to generate constraints for security features, and (b) lays out an end-to-end integrated methodology using separate network and power simulations to assess system risk. We demonstrate our approach by performing a systems-style analysis of a load-drop attack implemented over the AMI subsystem and targeted at destabilizing the underlying power grid.

  4. Applications of CCSDS recommendations to Integrated Ground Data Systems (IGDS)

    Science.gov (United States)

    Mizuta, Hiroshi; Martin, Daniel; Kato, Hatsuhiko; Ihara, Hirokazu

    1993-01-01

    This paper describes an application of the CCSDS Principle Network (CPH) service model to communications network elements of a postulated Integrated Ground Data System (IGDS). Functions are drawn principally from COSMICS (Cosmic Information and Control System), an integrated space control infrastructure, and the Earth Observing System Data and Information System (EOSDIS) Core System (ECS). From functional requirements, this paper derives a set of five communications network partitions which, taken together, support proposed space control infrastructures and data distribution systems. Our functional analysis indicates that the five network partitions derived in this paper should effectively interconnect the users, centers, processors, and other architectural elements of an IGDS. This paper illustrates a useful application of the CCSDS (Consultive Committee for Space Data Systems) Recommendations to ground data system development.

  5. 30 CFR 75.803 - Fail safe ground check circuits on high-voltage resistance grounded systems.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fail safe ground check circuits on high-voltage resistance grounded systems. 75.803 Section 75.803 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... High-Voltage Distribution § 75.803 Fail safe ground check circuits on high-voltage resistance...

  6. PMEL contributions to the collaboration: SCALING THE EARTH SYSTEM GRID TO PETASCALE DATA for the DOE SciDACs Earth System Grid Center for Enabling Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Hankin, Steve

    2012-06-01

    Drawing to a close after five years of funding from DOE's ASCR and BER program offices, the SciDAC-2 project called the Earth System Grid (ESG) Center for Enabling Technologies has successfully established a new capability for serving data from distributed centers. The system enables users to access, analyze, and visualize data using a globally federated collection of networks, computers and software. The ESG software now known as the Earth System Grid Federation (ESGF) has attracted a broad developer base and has been widely adopted so that it is now being utilized in serving the most comprehensive multi-model climate data sets in the world. The system is used to support international climate model intercomparison activities as well as high profile U.S. DOE, NOAA, NASA, and NSF projects. It currently provides more than 25,000 users access to more than half a petabyte of climate data (from models and from observations) and has enabled over a 1,000 scientific publications.

  7. A Multi-Agent System Architecture for Smart Grid Management and Forecasting of Energy Demand in Virtual Power Plants

    OpenAIRE

    Hernández, Luis; Baladrón Zorita, Carlos; Aguiar Pérez, Javier Manuel; Carro, Belén; Sanchez-Esguevillas, Antonio; Lloret, Jaime; Chinarro, David; Gómez Sanz, Jorge; Cook, Diane

    2013-01-01

    Recent technological advances in the power generation and information technologies areas are helping to change the modern electricity supply system in order to comply with higher energy efficiency and sustainability standards. Smart grids are an emerging trend that introduce intelligence in the power grid to optimize resource usage. In order for this intelligence to be effective, it is necessary to retrieve enough information about the grid operation together with other context data such as e...

  8. Foundational Report Series: Advanced Distribution Management Systems for Grid Modernization

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jianhui [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-01

    This report describes the application functions for distribution management systems (DMS). The application functions are those surveyed by the IEEE Power and Energy Society’s Task Force on Distribution Management Systems. The description of each DMS application includes functional requirements and the key features and characteristics in current and future deployments, as well as a summary of the major benefits provided by each function to stakeholders — from customers to shareholders. Due consideration is paid to the fact that the realizable benefits of each function may differ by type of utility, whether investor-owned, cooperative, or municipal. This report is sufficient to define the functional requirements of each application for system procurement (request-for-proposal [RFP]) purposes and for developing preliminary high-level use cases for those functions. However, it should not be considered a design document that will enable a vendor or software developer to design and build actual DMS applications.

  9. Ground Source Heat Pump in Heating System with Electronics Monitoring

    Directory of Open Access Journals (Sweden)

    NEAMŢU Ovidiu

    2013-10-01

    Full Text Available The monitoring system is implemented for a ground coupled heat pump in heating/ system. The borehole heat exchangers – which are 150 m long - are filled with a mixture of water and ethilene glycol calledbrine. Metering and monitoring energy consumption is achieved for: heat pump, circulation pumps, additional electrical heating, hot air ventilation systems, control systems with sensors: analog and smart sensors. Instantaneous values are stored in a local computer.

  10. A Dynamic Mobile Grid System for 4G Networks

    Science.gov (United States)

    Abdelkader, Manel; Boudriga, Mohamed Hamdi Noureddine

    Future networks specially International Mobile Telecommunications-advanced, better known as 4G, will come up with a panoply of services so as to provide a comprehensive and secure IP-based solution where facilities such as voice, data and stremed multimedia will be provided to users anywhere at anytime. This solution will also provide much higher data rates compared to previous generations. More importantly, the 4G architecture will strongly promote ubiquitous computing, which involves many computational devices and systems simultaneously. Such devices and systems can even be unaware that they are contributing to computational process.

  11. The Interim : until you achieve an operationally responsive ground system

    Science.gov (United States)

    Wendlandt, Bob; Clarke, Kelly; Lei, Jordan; Miyamoto, Charles; Owen-Mankovich, Kyran

    2008-01-01

    Everyone wants to achieve a 'Responsive' Ground Data System (GDS), but that takes time. What do you do in the interim? Our group, called the Integration, Test and Deployment Team (ITD), is a group of responsive engineers whose primary focus is to assist JPL projects to successfully adapt, test, integrate and deploy their ground data system. The team configures and adapts the GDS for a project, so that analysts, engineers and scientist do not need to be experts in the GDS to operate it. The team has developed a human interface to accommodate all types of users. It provides Graphical User Interfaces (GUI's) for those that want GUI's, command line interfaces for those that want control, and selection button interfaces for other users. The cornerstone of a responsive Ground Data System is responsive people. Without individuals who can be aware of a project's changing needs and requirements, how can the GDS become responsive

  12. Does your domestic photovoltaic energy system survive grid outages?

    NARCIS (Netherlands)

    Jongerden, Marijn R.; Hüls, Jannik; Remke, Anne; Haverkort, Boudewijn R.

    2016-01-01

    Domestic renewable energy systems, including photovoltaic energy generation, as well as local storage, are becoming increasingly popular and economically feasible, but do come with a wide range of options. Hence, it can be difficult to match their specification to specific customer’s needs. Next to

  13. EMISSIONS REDUCTION DATA FOR GRID-CONNECTED PHOTOVOLTAIC POWER SYSTEMS

    Science.gov (United States)

    This study measured the pollutant emission reduction potential of 29 photovoltaic (PV) systems installed on residential and commercial building rooftops across the U.S. from 1993 through 1997. The U.S. Environmental Protection Agency (EPA) and 21 electric power companies sponsor...

  14. Hybrid mini-grid systems – electricity for communities not connected to the national electricity grid based on renewable energy resources

    CSIR Research Space (South Africa)

    Szewczuk, S

    2008-11-01

    Full Text Available Africa’s first hybrid mini-grid energy system at the Hluleka Nature Reserve on the Wild Coast of the Eastern Cape province of South Africa. This paper describes the three-year investigative project in the Eastern Cape province, the formulation...

  15. Corrosion Behavior of Copper-Clad Steel Bars with Unclad Two-End Faces for Grounding Grids in the Red Clay Soil

    Science.gov (United States)

    Shao, Yupei; Mu, Miaomiao; Zhang, Bing; Nie, Kaibin; Liao, Qiangqiang

    2017-02-01

    Iron-aluminum oxides in the red soil have a significant impact on the corrosion behavior of the metal for grounding grids. Effects of iron-aluminum oxides on the corrosion behavior of the cross section of copper-clad steel in the red soil have been investigated using electrochemical impedance spectroscopy and Tafel polarization. All the data indicate that the iron-aluminum oxides can promote the corrosion of copper-clad steel in the red soil. The corrosivity of the red soil greatly increases after iron-aluminum oxides are added into the soil. Iron-aluminum oxides promote galvanic corrosion of copper-clad steel and increase the corrosion degree of the center steel layer. The iron-aluminum oxides stimulate corrosion process of copper-clad steel acting as a cathodic depolarizing agent. XRD results further validate that the corrosion products of the copper-clad steel bar mainly consist of Fe3O4 and Cu2O.

  16. Corrosion Behavior of Copper-Clad Steel Bars with Unclad Two-End Faces for Grounding Grids in the Red Clay Soil

    Science.gov (United States)

    Shao, Yupei; Mu, Miaomiao; Zhang, Bing; Nie, Kaibin; Liao, Qiangqiang

    2017-04-01

    Iron-aluminum oxides in the red soil have a significant impact on the corrosion behavior of the metal for grounding grids. Effects of iron-aluminum oxides on the corrosion behavior of the cross section of copper-clad steel in the red soil have been investigated using electrochemical impedance spectroscopy and Tafel polarization. All the data indicate that the iron-aluminum oxides can promote the corrosion of copper-clad steel in the red soil. The corrosivity of the red soil greatly increases after iron-aluminum oxides are added into the soil. Iron-aluminum oxides promote galvanic corrosion of copper-clad steel and increase the corrosion degree of the center steel layer. The iron-aluminum oxides stimulate corrosion process of copper-clad steel acting as a cathodic depolarizing agent. XRD results further validate that the corrosion products of the copper-clad steel bar mainly consist of Fe3O4 and Cu2O.

  17. A Smart Home Test Bed for Undergraduate Education to Bridge the Curriculum Gap from Traditional Power Systems to Modernized Smart Grids

    Science.gov (United States)

    Hu, Qinran; Li, Fangxing; Chen, Chien-fei

    2015-01-01

    There is a worldwide trend to modernize old power grid infrastructures to form future smart grids, which will achieve efficient, flexible energy consumption by using the latest technologies in communication, computing, and control. Smart grid initiatives are moving power systems curricula toward smart grids. Although the components of smart grids…

  18. Grid reliability

    Science.gov (United States)

    Saiz, P.; Andreeva, J.; Cirstoiu, C.; Gaidioz, B.; Herrala, J.; Maguire, E. J.; Maier, G.; Rocha, R.

    2008-07-01

    Thanks to the Grid, users have access to computing resources distributed all over the world. The Grid hides the complexity and the differences of its heterogeneous components. In such a distributed system, it is clearly very important that errors are detected as soon as possible, and that the procedure to solve them is well established. We focused on two of its main elements: the workload and the data management systems. We developed an application to investigate the efficiency of the different centres. Furthermore, our system can be used to categorize the most common error messages, and control their time evolution.

  19. A Fast Algorithm for Large-Scale MDP-Based Systems in Smart Grid

    Directory of Open Access Journals (Sweden)

    Hua Xiao

    2013-01-01

    Full Text Available In this study, we investigate the fast algorithms for the Large-Scale Markov Decision Process (LSMDP problem in smart gird. Markov decision process is one of the efficient mathematical tools to solve the control and optimization problems in wireless smart grid systems. However, the complexity and the memory requirements exponentially increase when the number of system state grows in. Moreover, the limited computational ability and small size of memory on board constraint the application of wireless smart grid systems. As a result, it is impractical to implement those LSMDP-based approaches in such systems. Therefore, we propose the fast algorithm with low computational overhead and good performance in this study. We first derive the factored MDP representation, which substitutes LSMDP in a compact way. Based on the factored MDP, we propose the fast algorithm, which considerably reduces the size of state space and remains reasonable performance compared to the optimal solution.

  20. Security Policies for Mitigating the Risk of Load Altering Attacks on Smart Grid Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, Tatyana; AlMajali, Anas; Neuman, Clifford

    2015-04-01

    While demand response programs implement energy efficiency and power quality objectives, they bring potential security threats to the Smart Grid. The ability to influence load in a system enables attackers to cause system failures and impacts the quality and integrity of power delivered to customers. This paper presents a security mechanism to monitor and control load according to a set of security policies during normal system operation. The mechanism monitors, detects, and responds to load altering attacks. We examined the security requirements of Smart Grid stakeholders and constructed a set of load control policies enforced by the mechanism. We implemented a proof of concept prototype and tested it using the simulation environment. By enforcing the proposed policies in this prototype, the system is maintained in a safe state in the presence of load drop attacks.

  1. Achieving High Performance Distributed System: Using Grid, Cluster and Cloud Computing

    Directory of Open Access Journals (Sweden)

    Sunil Kr Singh

    2015-02-01

    Full Text Available To increase the efficiency of any task, we require a system that would provide high performance along with flexibilities and cost efficiencies for user. Distributed computing, as we are all aware, has become very popular over the past decade. Distributed computing has three major types, namely, cluster, grid and cloud. In order to develop a high performance distributed system, we need to utilize all the above mentioned three types of computing. In this paper, we shall first have an introduction of all the three types of distributed computing. Subsequently examining them we shall explore trends in computing and green sustainable computing to enhance the performance of a distributed system. Finally presenting the future scope, we conclude the paper suggesting a path to achieve a Green high performance distributed system using cluster, grid and cloud computing

  2. Performance of a grid connected PV system used as active filter

    Energy Technology Data Exchange (ETDEWEB)

    Calleja, H. [Cenidet, Morelos (Mexico). Electronics Dept.; Jimenez, H. [IIE, Morelos (Mexico). Conventional Energy Sources Dept.

    2004-09-01

    In this paper, the performance of a grid connected photovoltaic (PV) system used as an active filter is presented. its main feature is the capability to compensate the reactive and harmonic currents drawn by nonlinear loads while simultaneously injecting into the grid the maximum power available from the cells. The system can also operate as a stand alone active filter. The system was connected to a 1 kW PV array and tested with the loads typically found in households: small motors, personal computers and electronic ballasts. The results show that the system can correct the power factor to values close to unity for all the cases tested, thereby improving the efficiency of the electric energy supply. (author)

  3. Does your domestic photovoltaic energy system survive grid outages?

    OpenAIRE

    Jongerden, Marijn R.; Jannik Hüls; Anne Remke; Haverkort, Boudewijn R.

    2016-01-01

    Domestic renewable energy systems, including photovoltaic energy generation, as well as local storage, are becoming increasingly popular and economically feasible, but do come with a wide range of options. Hence, it can be difficult to match their specification to specific customer’s needs. Next to the usage-specific demand profiles and location-specific production profiles, local energy storage through the use of batteries is becoming increasingly important, since it allows one to balance va...

  4. Advanced Analysis of Grid-connected PV System's Performance and Effect of Battery

    Science.gov (United States)

    Ueda, Yuzuru; Kurokawa, Kosuke; Itou, Takamitsu; Kitamura, Kiyoyuki; Akanuma, Katsumi; Yokota, Masaharu; Sugihara, Hiroyuki; Morimoto, Atsushi

    An advanced analysis method for grid connected PV systems is developed in this research. To investigate the issues which may happen in the clustered PV systems, “Demonstrative research on clustered PV systems" is being conducted from December, 2002, in Oota, Japan. More than 500 residential PV systems will be installed in the demonstrative research area, battery integrated PV systems are developed to avoid the restriction of output power due to the raising of grid voltage. Annual performance of commercial PV systems without battery is analyzed and resulted in around 80% of performance ratio on the average. Over voltage of power distribution line and snow are two major factors of very low performance ratio on daily basis. Effects of batteries are also analyzed, the results indicate that there will be some improvement for the energy loss due to the grid voltage but PCS's efficiency will be around 8% worse than that of the commercial PV systems. It is also found that the non-optimized operation of battery sometimes results in the fully-charged situation during the noontime and maximum reverse power flow may not be minimized in this situation.

  5. CT reclassification system cuts costs of grid metering

    Energy Technology Data Exchange (ETDEWEB)

    Doig, P. [Schneider Electric, Toronto, ON (Canada)

    2006-07-01

    New regulatory requirements demand that utilities meter previously un-metered locations on the power network with accurate revenue metering equipment. Utilities are now exploring the possibility of re-using existing relay-class transformers (CTs) for metering applications. However, the true accuracy of the existing CTs is often unknown. This paper presented details of a new CT reclassification system. The system uses a highly accurate current sensor for use in live-line methods in a high voltage environment. The system analyzes the accuracy of an existing CT and calculates its characteristic performance. Corresponding error correction parameters are then obtained and programmed into an advanced revenue meter in order to enable dynamic accuracy reclassification of the existing CT while it is operational. The sensor is based on a split-core active CT design. In a typical installation, 3 primary sensors are installed on the high-side bus in a high voltage substation in series with the circuit breaker containing the existing relay-class CTs under test. The sensors each wirelessly stream data to a computer workstation in a nearby substation control building. The sensors and the advanced revenue meter are equipped with a global positioning system (GPS) receiver that support accurate time-stamping and synchronization of all data sent to the computer for analysis. Software is used to compare data from the sensors to the respective 3-phase data collected from the meter and to calculate the appropriate ratio correction factors and phase angle correction factors for each test point. Correction parameters are then programmed into the revenue meter which provides dynamic correction for the ratio and phase angle errors of the relay-class CT over its operational range. The revenue meter is left in place after the sensors are removed in order to measure highly accurate energy data which is reported back to the utility data collection and billing system. Details of a test conducted

  6. Structural factors of solar system cluster ground coupled storage rationalization

    Directory of Open Access Journals (Sweden)

    Viktor V. Wysochin

    2015-12-01

    Full Text Available The computational investigations of unsteady heat transfer in seasonal solar heat storage system were conducted. This storage system consists of nine ground heat exchangers. The investigations were made for periodical diurnal cycle charging during summer season. The heat exchanger is presented as vertical probe with concentric tubes arrangement. Aim: The aim of the work is the optimization of cluster ground coupled storage – the probes quantity in cluster, their lengths and interval – using high precision mathematical model. Materials and Methods: The mathematical model of conjugate solar system functioning and ground coupled storage involves differential equations describing the incoming and conversion of solar energy in solar collector. Also it includes the heat exchange in ground heat exchangers and three-dimensional soil mass. Results: The need of mutual influence accounting of the solar collector and the ground heat exchanger size ranges is shown. One more thing – capability of effectiveness improvement of the collector based on reasonable step size selection for cluster and selection of active heat exchangers quantity in requisite construction. Conclusions: The recommendations for organization of heat exchangers of the collector work are offered. The five-probe structure is the most effective one for cluster arrangement of seasonal heat storage. The recommended interval between probes is 4 meters.

  7. Application of magnetic pulse compression to the grid system of the ETA/ATA accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Birx, D.L.; Cook, E.G.; Reginato, L.L.; Schmidt, J.A.; Smith, M.W.

    1982-11-02

    During the past year, several magnetic pulse compression systems have been built and applied to the ETA accelerator. In view of their excellent performance, a non-linear magnetic system has been adopted for the ATA grid drive in place of the spark gap driven Blumlein. The magnetic system will give us a much higher reliability and greater flexibility by being independent of the high pressure gas blown system. A further advantage of this system will be the capability of achieving higher rep-rates in case of a future upgrade. System design and performance under burst mode will be described.

  8. Marketing residential grid-connected PV systems using a balanced scorecard as a marketing tool

    Energy Technology Data Exchange (ETDEWEB)

    Bach, N. [University of Giessen (Germany). Dept. of Organisation and Management; Calais, P. [Murdoch University, Perth (Australia). School of Environmental Science; Calais, M. [Curtin University, Perth (Australia). Centre for Renewable Systems Technology

    2001-03-01

    A strategic analysis of the electricity market in Western Australia yields a market potential for renewable energy in Western Australia. However, from a purely financial viewpoint the installation of grid-connected pv-systems still is not economically viable. In this paper a balanced scorecard (BSC) is developed to capture and visualize other than financial benefits. Therefore, the BSC can be used as a marketing tool to communicate the benefits of a privately owned GCPV system to potential customers. (author)

  9. PV grid connected system with fuzzy intelligent control

    Directory of Open Access Journals (Sweden)

    Florin DRAGOMIR

    2009-05-01

    Full Text Available This paper proposes an engineering solution for stability control of the low voltage electrical networks with distributed power generation from renewable energy resources. First there are presentedgenerally, the existing problems in this type of systems, capable to be solved with automation intelligent control. In the second part, the paper focuses over fuzzy controller design based on experimentalmonitored data and experts know how. The results of proposed software realized with LabView will be pointed out from the main objective point of view.

  10. Probability of islanding in utility networks due to grid connected photovoltaic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Verhoeven, B.

    2002-09-15

    This report for the International Energy Agency (IEA) made by Task 5 of the Photovoltaic Power Systems (PVPS) programme takes a look at the probability of islanding in utility networks due to grid-connected photovoltaic power systems. The mission of the Photovoltaic Power Systems Programme is to enhance the international collaboration efforts which accelerate the development and deployment of photovoltaic solar energy. Task 5 deals with issues concerning grid-interconnection and distributed PV power systems. This report summarises the results on a study on the probability of islanding in power networks with a high penetration level of grid connected PV-systems. The results are based on measurements performed during one year in a Dutch utility network. The measurements of active and reactive power were taken every second for two years and stored in a computer for off-line analysis. The area examined and its characteristics are described, as are the test set-up and the equipment used. The ratios between load and PV-power are discussed. The general conclusion is that the probability of islanding is virtually zero for low, medium and high penetration levels of PV-systems.

  11. Grid Connected Solar PV System with SEPIC Converter Compared with Parallel Boost Converter Based MPPT

    Directory of Open Access Journals (Sweden)

    T. Ajith Bosco Raj

    2014-01-01

    Full Text Available The main objective of this work is to study the behaviour of the solar PV systems and model the efficient Grid-connected solar power system. The DC-DC MPPT circuit using chaotic pulse width modulation has been designed to track maximum power from solar PV module. The conversion efficiency of the proposed MPPT system is increased when CPWM is used as a control scheme. This paper also proposes a simplified multilevel (seven level inverter for a grid-connected photovoltaic system. The primary goal of these systems is to increase the energy injected to the grid by keeping track of the maximum power point of the panel, by reducing the switching frequency, and by providing high reliability. The maximum power has been tracked experimentally. It is compared with parallel boost converter. Also this model is based on mathematical equations and is described through an equivalent circuit including a PV source with MPPT, a diode, a series resistor, a shunt resistor, and dual boost converter with active snubber circuit. This model can extract PV power and boost by using dual boost converter with active snubber. By using this method the overall system efficiency is improved thereby reducing the switching losses and cost.

  12. Probing quantum frustrated systems via factorization of the ground state.

    Science.gov (United States)

    Giampaolo, Salvatore M; Adesso, Gerardo; Illuminati, Fabrizio

    2010-05-21

    The existence of definite orders in frustrated quantum systems is related rigorously to the occurrence of fully factorized ground states below a threshold value of the frustration. Ground-state separability thus provides a natural measure of frustration: strongly frustrated systems are those that cannot accommodate for classical-like solutions. The exact form of the factorized ground states and the critical frustration are determined for various classes of nonexactly solvable spin models with different spatial ranges of the interactions. For weak frustration, the existence of disentangling transitions determines the range of applicability of mean-field descriptions in biological and physical problems such as stochastic gene expression and the stability of long-period modulated structures.

  13. Special issue on advancing grid-connected renewable generation systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Yang, Yongheng

    2017-01-01

    Renewables are heavily involved in power generation, as an essential component for today’s energy paradigm. Energy structure—both national and international—has been undergoing significant changes over the past few decades. For instance, in Denmark, power generation is shifting from fossil......-fuel-based to renewable-based in terms of energy sources, from centralized to decentralized in terms of architectures, and from sole to miscellaneous in terms of energy varieties [1]. In this energy evolution, the power electronic technology plays an enabling role in the integration and advancements of renewables......—such as wind turbine, photovoltaics, fuel cells, and other emerging energy systems. At the same time, various control strategies are necessary to guide the energy integration (i.e., to enhance the energy transition), and on the other hand, to flexibly, reliably, and efficiently utilize the energy. Tremendous...

  14. Ground-Based Calibration Of A Microwave Landing System

    Science.gov (United States)

    Kiriazes, John J.; Scott, Marshall M., Jr.; Willis, Alfred D.; Erdogan, Temel; Reyes, Rolando

    1996-01-01

    System of microwave instrumentation and data-processing equipment developed to enable ground-based calibration of microwave scanning-beam landing system (MSBLS) at distances of about 500 to 1,000 ft from MSBLS transmitting antenna. Ensures accuracy of MSBLS near touchdown point, without having to resort to expense and complex logistics of aircraft-based testing. Modified versions prove useful in calibrating aircraft instrument landing systems.

  15. 0{sup +} ground state dominance in many-body systems

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yu-Min [Southeast Univ., Dept. of Physics, Nanjing (China); Arima, Akito [The House of Councilors, Tokyo (Japan); Yoshinaga, Naotaka [Saitama Univ., Physics Dept., Saitama (Japan)

    2002-12-01

    We propose a simple approach to predict the angular momentum I ground states (Ig.s.) probabilities of many-body systems without diagonalization of the hamiltonian using random interactions. It is suggested that the 0g.s. dominance in boson systems and even valence nucleon systems is not given by the model space as previously assumed, but by specific two-body interactions. (author)

  16. Ground Source Geothermal District Heating and Cooling System

    Energy Technology Data Exchange (ETDEWEB)

    Lowe, James William [Ball State Univ., Muncie, IN (United States)

    2016-10-21

    Ball State University converted its campus from a coal-fired steam boiler district heating system to a ground source heat pump geothermal district system that produces simultaneously hot water for heating and chilled water for cooling. This system will include the installation of 3,600 four hundred feet deep vertical closed loop boreholes making it the largest ground source geothermal district system in the country. The boreholes will act as heat exchangers and transfer heat by virtue of the earth’s ability to maintain an average temperature of 55 degree Fahrenheit. With growing international concern for global warming and the need to reduce worldwide carbon dioxide loading of the atmosphere geothermal is poised to provide the means to help reduce carbon dioxide emissions. The shift from burning coal to utilizing ground source geothermal will increase electrical consumption but an overall decrease in energy use and reduction in carbon dioxide output will be achieved. This achievement is a result of coupling the ground source geothermal boreholes with large heat pump chiller technology. The system provides the thermodynamic means to move large amounts of energy with limited energy input. Ball State University: http://cms.bsu.edu/About/Geothermal.aspx

  17. Grid-connection of offshore wind farms using VSC-HVDC systems

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Xiaofan; Dessaint, Louis A. [Ecole de Technologie Superieure, Montreal, QC (Canada). Dept. of Electrical Engineering; Gagnon, Richard [Hydro-Quebec Research Institute, Montreal, QC (Canada)

    2011-07-01

    In this paper, the structure of variable speed PMSG-based offshore wind farms connected to the grid through VSC-HVDC link is presented. And the system models are developed. Also, the corresponding control strategy for this system is proposed. The control objective of the generator side VSC is to achieve the optimal wind power by adjusting the speed of permanent magnet synchronous generator, while the grid side VSC is to maintain DC voltage constant. Furthermore, a case study of 100MW offshore wind farm consisting of 50 individual 2MW PSMG-based wind turbines is developed in MATLAB/SimPowerSystems. Simulation results show the proposed scheme works well. (orig.)

  18. The Integration and Control of Multifunctional Stationary PV-Battery Systems in Smart Distribution Grid

    DEFF Research Database (Denmark)

    Khan, Mohammad Rezwan; Mulder, Grietus; Van Mierlo, Joeri

    2013-01-01

    . The objective of this paper is to develop and detail the method of optimum sizing energy storage for grid connected distribution systems using newly devised BESS control protocol and investigate its sensitivity to factors which are known to influence energy system performance and hence storage requirements......The paper investigates the potential of using lumped stationary battery energy storage systems (BESS) in the public low-voltage distribution grid in order to defer upgrades needed in case of large penetration of electric vehicle (EV), electrified heat pump (HP) in presence of photovoltaic (PV......) panel on the view of techno economic optimal sizing taking the consideration of season-based diurnal dynamics. The BESS is primarily dimensioned for the peak shaving operation targeted for the counterbalance of overloading of transformer; BESS also participates in arbitrage (buy low, sell high...

  19. Reactive Power Injection Strategies for Single-Phase Photovoltaic Systems Considering Grid Requirements

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    like what the conventional power plants do today in the grid regulation participation. Requirements of ancillary services like Low-Voltage Ride-Through (LVRT) associated with reactive current injection and voltage support through reactive power control, have been in effectiveness in some countries...... possibilities are: a) constant average active power control, b) constant active current control, c) constant peak current control and d) thermal optimized control strategy. All those strategies comply with the currently active grid codes, but are with different objectives. The thermal optimized control strategy....... Those advanced features can be provided by next-generation PV systems, and will be enhanced in the future to ensure an even efficient and reliable utilization of PV systems. In the light of this, Reactive Power Injection (RPI) strategies for single-phase PV systems are explored in this paper. The RPI...

  20. Reactive Power Injection Strategies for Single-Phase Photovoltaic Systems Considering Grid Requirements

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    like what the conventional power plants do today in the grid regulation participation. Requirements of ancillary services like Low-Voltage Ride-Through (LVRT) associated with reactive current injection and voltage support through reactive power control, have been in effectiveness in some countries, e...... in this paper. The RPI possibilities are: a) constant average active power control, b) constant active current control, c) constant peak current control and d) thermal optimized control strategy. All those strategies comply with the currently active grid codes, but are with different objectives. The proposed.......g. Germany and Italy. Those advanced features can be provided by next generation PV systems, and will be enhanced in the future to ensure an even efficient and reliable utilization of PV systems. In light of this, Reactive Power Injection (RPI) strategies for single-phase PV systems are explored...

  1. Two-stage single-phase grid-connected photovoltaic system with reduced complexity

    Science.gov (United States)

    da Silva, Cintia S.; Motta, Filipe R.; Tofoli, Fernando L.

    2011-06-01

    This article presents a grid-connected photovoltaic (PV) system using the classical DC-DC buck converter, which is responsible for stepping down the resulting voltage from several series-connected panels. Besides, the structure provides high power factor operation by injecting a quasi-sinusoidal current into the grid, with near no displacement in relation to the line voltage at the point of common coupling among the PV system and the loads. A CSI employing thyristors is cascaded with the DC-DC stage so that AC voltage results. The inverter output voltage level is adjusted by using a low-frequency transformer, which also provides galvanic isolation. The proposed system is described as mathematical approach and design guidelines are presented, providing an overview of the topology. An experimental prototype is also implemented, and relevant results to validate the proposal are discussed.

  2. Grid Integration of Single Stage Solar PV System using Three-level Voltage Source Converter

    Science.gov (United States)

    Hussain, Ikhlaq; Kandpal, Maulik; Singh, Bhim

    2016-08-01

    This paper presents a single stage solar PV (photovoltaic) grid integrated power generating system using a three level voltage source converter (VSC) operating at low switching frequency of 900 Hz with robust synchronizing phase locked loop (RS-PLL) based control algorithm. To track the maximum power from solar PV array, an incremental conductance algorithm is used and this maximum power is fed to the grid via three-level VSC. The use of single stage system with three level VSC offers the advantage of low switching losses and the operation at high voltages and high power which results in enhancement of power quality in the proposed system. Simulated results validate the design and control algorithm under steady state and dynamic conditions.

  3. Operating conditions of batteries in off-grid renewable energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Svoboda, Vojtech [University of Hawaii, 1680 East-West Rd., Post 109, Honolulu, HI 96822, (United States); Wenzl, Heinz [Beratung fuer Batterien und Energietechnik, Am Bergwaeldchen 27, 37520 Osterode (Germany); Kaiser, Rudi [Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, 79110 Freiburg (Germany); Jossen, Andreas [Center for Solar Energy and Hydrogen Research Baden - Wuerttemberg, Helmholtzstrasse 8, 89081 Ulm (Germany); Baring-Gould, Ian [National Renewable Energy Laboratory, MS 3811, 1617 Cole Blvd, 80401-3393 Golden/CO (United States); Manwell, James [University of Massachusetts, Amherst, Massachusetts, MA 01003 (United States); Lundsager, Per; Bindner, Henrik; Cronin, Tom; Noergaard, Per [Riseo National Laboratory, P.O. Box 49, Frederiksborgvej 399, 4000 Roskilde (Denmark); Ruddell, Alan [Council for the Central Laboratory of the Research Councils, Rutherford Appleton Laboratory, Energy Research Unit, Chilton, OX11 0QX Didcot (United Kingdom); Perujo, Adolfo; Douglas, Kevin [E.C. Joint Research Centre, Institute for Environment and Sustainability, 21020 Ispra VA (Italy); Rodrigues, Carlos; Joyce, Antonio [INETI, Department of Renewable Energy, Estrada do Paco de Lumiar 22, 1649-038 Lisbon (Portugal); Tselepis, Stathis [Center for Renewable Energy Sources, 19th km Marathonos Ave., 19009 Pikermi (Greece); Borg, Nico van der; Nieuwenhout, Frans [The Netherlands Energy Research Foundation, P.O. Box 1, 1755 ZG Petten (Netherlands); Wilmot, Nigel [Research Institute for Sustainable Energy, Murdoch University, South Street, 6150 Perth (Australia); Mattera, Florence [Commissariat a l' Energetie Atomicque, Groupement Energetique de Cadarache, 38054 Grenoble (France)

    2007-11-15

    Operating conditions in off-grid renewable energy systems (RES) vary significantly in different applications and locations. To describe RES and the operating conditions of their components it is useful to define categories of similar operating conditions. Categories can also be used for lifetime considerations of RES components, for making recommendations and for analysing the properties and performance of a RES and its components. Categories support system designers and an economic analysis. This paper describes the process and the results of creating RES categories of similar operating conditions for batteries. Categories are defined in such a way that batteries belonging to the same category are subjected to similar operating conditions and a similar combination of stress factors. The results provide a comprehensive overview of battery operating conditions in existing off-grid renewable energy systems. This work is part of the EU research project Benchmarking. (author)

  4. Operating conditions of batteries in off-grid renewable energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Svoboda, Vojtech; Wenzl, Heinz; Kaiser, Rudi; Jossen, Andreas; Baring-Gould, Ian; Manwell, James; Lundsager, Per; Bindner, Henrik; Cronin, Tom; Nørgård, Per; Ruddell, Alan; Perujo, Adolfo; Douglas, Kevin; Rodrigues, Carlos; Joyce, António; Tselepis, Stathis; van der Borg, Nico; Nieuwenhout, Frans; Wilmot, Nigel; Mattera, Florence; Sauer, Dirk Uwe

    2007-11-01

    Operating conditions in off-grid renewable energy systems (RES) vary significantly in different applications and locations. To describe RES and the operating conditions of their components it is useful to define categories of similar operating conditions. Categories can also be used for lifetime considerations of RES components, for making recommendations and for analysing the properties and performance of a RES and its components. Categories support system designers and an economic analysis. This paper describes the process and the results of creating RES categories of similar operating conditions for batteries. Categories are defined in such a way that batteries belonging to the same category are subjected to similar operating conditions and a similar combination of stress factors. The results provide a comprehensive overview of battery operating conditions in existing off-grid renewable energy systems. This work is part of the EU research project Benchmarking.

  5. Operating conditions of batteries in off-grid renewable energy systems

    DEFF Research Database (Denmark)

    Svoboda, V.; Wenzl, H.; Kaiser, R.

    2007-01-01

    Operating conditions in off-grid renewable energy systems (RES) vary significantly in different applications and locations. To describe RES and the operating conditions of their components it is useful to define categories of similar operating conditions. Categories can also be used for lifetime...... considerations of RES components, for making recommendations and for analysing the properties and performance of a RES and its components. Categories support system designers and an economic analysis. This paper describes the process and the results of creating RES categories of similar operating conditions...... for batteries. Categories are defined in such a way that batteries belonging to the same category are subjected to similar operating conditions and a similar combination of stress factors. The results provide a comprehensive overview of battery operating conditions in existing off-grid renewable energy systems...

  6. Solar activity and economic fundamentals: Evidence from 12 geographically disparate power grids

    Science.gov (United States)

    Forbes, Kevin F.; St. Cyr, O. C.

    2008-10-01

    This study uses local (ground-based) magnetometer data as a proxy for geomagnetically induced currents (GICs) to address whether there is a space weather/electricity market relationship in 12 geographically disparate power grids: Eirgrid, the power grid that serves the Republic of Ireland; Scottish and Southern Electricity, the power grid that served northern Scotland until April 2005; Scottish Power, the power grid that served southern Scotland until April 2005; the power grid that serves the Czech Republic; E.ON Netz, the transmission system operator in central Germany; the power grid in England and Wales; the power grid in New Zealand; the power grid that serves the vast proportion of the population in Australia; ISO New England, the power grid that serves New England; PJM, a power grid that over the sample period served all or parts of Delaware, Maryland, New Jersey, Ohio, Pennsylvania, Virginia, West Virginia, and the District of Columbia; NYISO, the power grid that serves New York State; and the power grid in the Netherlands. This study tests the hypothesis that GIC levels (proxied by the time variation of local magnetic field measurements (dH/dt)) and electricity grid conditions are related using Pearson's chi-squared statistic. The metrics of power grid conditions include measures of electricity market imbalances, energy losses, congestion costs, and actions by system operators to restore grid stability. The results of the analysis indicate that real-time market conditions in these power grids are statistically related with the GIC proxy.

  7. Power control and management of the grid containing largescale wind power systems

    Science.gov (United States)

    Aula, Fadhil Toufick

    The ever increasing demand for electricity has driven many countries toward the installation of new generation facilities. However, concerns such as environmental pollution and global warming issues, clean energy sources, high costs associated with installation of new conventional power plants, and fossil fuels depletion have created many interests in finding alternatives to conventional fossil fuels for generating electricity. Wind energy is one of the most rapidly growing renewable power sources and wind power generations have been increasingly demanded as an alternative to the conventional fossil fuels. However, wind power fluctuates due to variation of wind speed. Therefore, large-scale integration of wind energy conversion systems is a threat to the stability and reliability of utility grids containing these systems. They disturb the balance between power generation and consumption, affect the quality of the electricity, and complicate load sharing and load distribution managing and planning. Overall, wind power systems do not help in providing any services such as operating and regulating reserves to the power grid. In order to resolve these issues, research has been conducted in utilizing weather forecasting data to improve the performance of the wind power system, reduce the influence of the fluctuations, and plan power management of the grid containing large-scale wind power systems which consist of doubly-fed induction generator based energy conversion system. The aims of this research, my dissertation, are to provide new methods for: smoothing the output power of the wind power systems and reducing the influence of their fluctuations, power managing and planning of a grid containing these systems and other conventional power plants, and providing a new structure of implementing of latest microprocessor technology for controlling and managing the operation of the wind power system. In this research, in order to reduce and smooth the fluctuations, two

  8. Smart Grid Wide-Area Transmission System Visualization

    Directory of Open Access Journals (Sweden)

    Thomas J. Overbye

    2015-12-01

    Full Text Available The installation of vast quantities of additional new sensing and communication equipment, in conjunction with building the computing infrastructure to store and manage data gathered by this equipment, has been the first step in the creation of what is generically referred to as the “smart grid” for the electric transmission system. With this enormous capital investment in equipment having been made, attention is now focused on developing methods to analyze and visualize this large data set. The most direct use of this large set of new data will be in data visualization. This paper presents a survey of some visualization techniques that have been deployed by the electric power industry for visualizing data over the past several years. These techniques include pie charts, animation, contouring, time-varying graphs, geographic-based displays, image blending, and data aggregation techniques. The paper then emphasizes a newer concept of using word-sized graphics called sparklines as an extremely effective method of showing large amounts of time-varying data.

  9. Evaluation of Grounding Impedance of a Complex Lightning Protective System Using Earth Ground Clamp Measurements and ATP Modeling

    Science.gov (United States)

    Mata, Carlos T.; Rakov, V. A.; Mata, Angel G.

    2010-01-01

    A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulators installed atop three towers in a triangular configuration. A total of nine downconductors (each about 250 meters long, on average) are connected to the catenary wire system. Each of the nine downconductors is connected to a 7.62-meter radius circular counterpoise conductor with six equally spaced 6-meter long vertical grounding rods. Grounding requirements at LC39B call for all underground and above ground metallic piping, enclosures, raceways, and cable trays, within 7.62 meters of the counterpoise, to be bounded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways, and cable trays that run in multiple direction around LC39B. The complexity of this grounding system makes the fall of potential method, which uses multiple metallic rods or stakes, unsuitable for measuring the grounding impedances of the downconductors. To calculate the downconductors grounding impedance, an Earth Ground Clamp (a stakeless grounding resistance measuring device) and a LPS Alternative Transient Program (ATP) model are used. The Earth Ground Clamp is used to measure the loop impedance plus the grounding impedance of each downconductor and the ATP model is used to calculate the loop impedance of each downconductor circuit. The grounding impedance of the downconductors is then calculated by subtracting the ATP calculated loop impedances from the Earth Ground Clamp measurements.

  10. Forecasting Wind and Solar Generation: Improving System Operations, Greening the Grid (Spanish Version)

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Tian; Chernyakhovskiy, Ilya; Brancucci Martinez-Anido, Carlo

    2016-04-01

    This document is the Spanish version of 'Greening the Grid- Forecasting Wind and Solar Generation Improving System Operations'. It discusses improving system operations with forecasting with and solar generation. By integrating variable renewable energy (VRE) forecasts into system operations, power system operators can anticipate up- and down-ramps in VRE generation in order to cost-effectively balance load and generation in intra-day and day-ahead scheduling. This leads to reduced fuel costs, improved system reliability, and maximum use of renewable resources.

  11. A probabilistic study of grid-connected wind electric conversion systems

    Science.gov (United States)

    Mohanpurkar, Manish

    Scope and Method of Study. Purpose of the study is to model the power output of Wind Electric Conversion System (WECS) as a random variable given that wind speeds incident on them is random. The model is extended to model probability functions for combined power outputs of multiple WECS located in a wind regime. The impact of variable region in the power characteristic on the probability functions for power output of individual and multiple WECS is investigated. This model is employed in performance assessment of wind farms within probabilistic framework to obtain its load supplying capability. Smart grid functionalities and Demand Side Management (DSM) are identified to have complementary behavior beneficial for optimal operation of electric grid. This is demonstrated using the obtained model for wind farms and a possible modification of load demand distribution function. Findings and Conclusions. The power output of WECS is a mixed random variable. Impact of exponent 'n' on the probability density function (pdf) for power output of multiple WECS is "minor" for a low number of WECS. For a large number of WECS, there occurs a major redistribution of probabilities of power outputs leading to distinct pdf plots for different exponents. Increasing wind penetration leads to flatter power duration curves. Smart grid functionalities and DSM techniques if complemented in a suitable manner will assist in greater assimilation of wind energy into the grid.

  12. Geospatial Applications on Different Parallel and Distributed Systems in enviroGRIDS Project

    Science.gov (United States)

    Rodila, D.; Bacu, V.; Gorgan, D.

    2012-04-01

    The execution of Earth Science applications and services on parallel and distributed systems has become a necessity especially due to the large amounts of Geospatial data these applications require and the large geographical areas they cover. The parallelization of these applications comes to solve important performance issues and can spread from task parallelism to data parallelism as well. Parallel and distributed architectures such as Grid, Cloud, Multicore, etc. seem to offer the necessary functionalities to solve important problems in the Earth Science domain: storing, distribution, management, processing and security of Geospatial data, execution of complex processing through task and data parallelism, etc. A main goal of the FP7-funded project enviroGRIDS (Black Sea Catchment Observation and Assessment System supporting Sustainable Development) [1] is the development of a Spatial Data Infrastructure targeting this catchment region but also the development of standardized and specialized tools for storing, analyzing, processing and visualizing the Geospatial data concerning this area. For achieving these objectives, the enviroGRIDS deals with the execution of different Earth Science applications, such as hydrological models, Geospatial Web services standardized by the Open Geospatial Consortium (OGC) and others, on parallel and distributed architecture to maximize the obtained performance. This presentation analysis the integration and execution of Geospatial applications on different parallel and distributed architectures and the possibility of choosing among these architectures based on application characteristics and user requirements through a specialized component. Versions of the proposed platform have been used in enviroGRIDS project on different use cases such as: the execution of Geospatial Web services both on Web and Grid infrastructures [2] and the execution of SWAT hydrological models both on Grid and Multicore architectures [3]. The current

  13. Performance of Grid-Connected Photovoltaic System in Two Sites in Kuwait

    Directory of Open Access Journals (Sweden)

    Ali Hajiah

    2012-01-01

    Full Text Available This paper presents an assessment of the electricity generated by photovoltaic (PV grid-connected systems in Kuwait. Three years of meteorological data are provided for two main sites in Kuwait, namely, Al-Wafra and Mutla. These data and a PV grid-connected system mathematical model are used to assist a 100 kWp grid-connected PV system proposed for both sites. The proposed systems show high energy productivity whereas the annual capacity factors for Mutla and Al-Wafra are 22.25% and 21.6%, respectively. Meanwhile the annual yield factors for Mutla and Al-Wafra are 1861 kWh/kWp/year and 1922.7 kWh/kWp/year, respectively. On the other hand the cost of the energy generated by both systems is about 0.1 USD/kWh which is very close to the price of the energy sold by the Ministry of Electricity and Water (MEW. Furthermore the invested money is recovered during the assumed life cycle time whereas the payback period for both sites is about 15 years. This work contains worthwhile technical information for those who are interested in PV technology investment in Kuwait.

  14. Development of an Advanced Grid-Connected PV-ECS System Considering Solar Energy Estimation

    Science.gov (United States)

    Rahman, Md. Habibur; Yamashiro, Susumu; Nakamura, Koichi

    In this paper, the development and the performance of a viable distributed grid-connected power generation system of Photovoltaic-Energy Capacitor System (PV-ECS) considering solar energy estimation have been described. Instead of conventional battery Electric Double Layer Capacitors (EDLC) are used as storage device and Photovoltaic (PV) panel to generate power from solar energy. The system can generate power by PV, store energy when the demand of load is low and finally supply the stored energy to load during the period of peak demand. To realize the load leveling function properly the system will also buy power from grid line when load demand is high. Since, the power taken from grid line depends on the PV output power, a procedure has been suggested to estimate the PV output power by calculating solar radiation. In order to set the optimum value of the buy power, a simulation program has also been developed. Performance of the system has been studied for different load patterns in different weather conditions by using the estimated PV output power with the help of the simulation program.

  15. Power conditioning system topology for grid integration of wind and fuell cell energy

    Directory of Open Access Journals (Sweden)

    Marian GAICEANU

    2006-12-01

    Full Text Available This paper shows the topology of the hybrid grid-connected power system and the performances of the front-end three-phase power inverter. The renewable sources of the hybrid power system consist of a solid oxide fuel cell and a wind-turbine. This type of combination is the most efficient one. The proposed topology benefits of the one common DC-AC inverter which injects the generated power into the grid. The architecture diminishes the cost of the power conditioning system. Moreover, due to the power balance control of the entire power conditioning system the bulk dc link electrolytic capacitor is replaced with a small plastic film one. The final power conditioning system has the following advantages: independent control of the reactive power, minimize harmonic current distortion offering a nearly unity power factor operation (0,998 operation capability, dc link voltage regulation (up to 5% ripple in the dc-link voltage in any operated conditions, fast disturbance compensation capability, high reliability, and low cost. The experimental test has been performed and the performances of the grid power inverter are shown.

  16. Discrete Global Grid Systems - A Framework for the next Era in Big Earth Data

    Science.gov (United States)

    Peterson, P. R.; Percivall, G.; Purss, M. B. J.; Samavati, F.; Gibb, R.

    2015-12-01

    Discrete Global Grid Systems (DGGS) are spatial reference systems that use a hierarchical tessellation of cells to partition and address the entire globe. DGGS are designed to portray real-world phenomena by providing a digital framework on a common discrete geospatial data structure and they are commonly used to create virtual globes. DGGS differ from conventional geographic coordinate reference systems in that they are designed to be an information grid not a navigation grid. Conventional coordinate reference systems address the globe using tuples of "real" numbered coordinates. DGGS, however, address the entire planet by partitioning it into a hierarchical tessellation of integer-based nested cells thereby providing a truly discrete, rather than continuous, reference frame for repeating the location of measured Earth observations, feature interpretations, and extrapolated predictions. Formal development of DGGS began in the 1980s with the promising value of global analysis coinciding with the increased use of geographic information systems and the availability of global mapping data and positioning systems. However, following the initial excitement about DGGS as a technology the lack of availability of suitable cloud and High Performance Computing (HPC) environments has limited the uptake and application of DGGS - until now! The maturation of accessible cloud and HPC infrastructures has enabled DGGS to emerge from the 'trough of disillusionment' and to provide a path to realizing the vision of the Digital Earth, and the future of CyberGIS. The Open Geospatial Consortium (OGC) is developing an international standard for DGGS that will formally define the essential properties of a DGGS and specify protocols that will facilitate interoperability between multiple DGGS and traditional data infrastructures. The OGC DGGS Standards Working Group is finalizing its work based on inputs and review from experts around the world with experinence using multiple DGGSs. By

  17. The Effect of Images on Surface Potential and Resistance Calculation of Grounding Systems

    Directory of Open Access Journals (Sweden)

    MARTINS, A.

    2015-05-01

    Full Text Available In the grounding systems with a two layers soil, the calculation of the surface potential using the image method is sometimes impossible due to singularities, avoiding researchers to use the method for electrodes in the bottom layer. In the literature this problem solution is refereed as unreliable or solved with other more complex methods. This paper presents a new approach to calculate the surface potentials in a two. layer soil, for electrodes in the bottom layer, when images are at surface. The singularities in computing surface voltage, when the first image upwards lies at surface, are analysed and it's shown that a small change in top layer thickness allows an approximate solution. Surface potentials due to grid conductor are also considered and the values of resistance are compared with those from other methodologies. Singularities for a ground rod that crosses the two layers are also treated. The obtained values of resistance are not satisfactory, due to lower segments images that overlap the upper segments. This paper also proposes shifting the surface of the upper part of the ground rod, in the upper layer, or taking the modulus of the mutual resistance, to overcome this difficulty.

  18. Adaptive Hysteresis Band Current Control (AHB) with PLL of Grid Side Converter-Based Wind Power Generation System

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Li, Lijuan

    2011-01-01

    Adaptive hysteresis band current control(AHB CC) is used to control the three-phase grid currents by means of grid side converter in wind power generation system in this paper. AHB has reached the good purpose with PLL (Lock phase loop). First the mathematical models of each part are given...

  19. Adaptive Hysteresis Band Current Control (AHB) with PLL of Grid Side Converter-Based Wind Power Generation System

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Li, Lijuan

    2011-01-01

    Adaptive hysteresis band current control(AHB CC) is used to control the three-phase grid currents by means of grid side converter in wind power generation system in this paper. AHB has reached the good purpose with PLL (Lock phase loop). First the mathematical models of each part are given...

  20. Thermal Protection System Cavity Heating for Simplified and Actual Geometries Using Computational Fluid Dynamics Simulations with Unstructured Grids

    Science.gov (United States)

    McCloud, Peter L.

    2010-01-01

    Thermal Protection System (TPS) Cavity Heating is predicted using Computational Fluid Dynamics (CFD) on unstructured grids for both simplified cavities and actual cavity geometries. Validation was performed using comparisons to wind tunnel experimental results and CFD predictions using structured grids. Full-scale predictions were made for simplified and actual geometry configurations on the Space Shuttle Orbiter in a mission support timeframe.

  1. High-Efficiency Food Production in a Renewable Energy Based Micro-Grid Power System

    Science.gov (United States)

    Bubenheim, David; Meiners, Dennis

    2016-01-01

    Controlled Environment Agriculture (CEA) systems can be used to produce high-quality, desirable food year round, and the fresh produce can positively contribute to the health and well being of residents in communities with difficult supply logistics. While CEA has many positive outcomes for a remote community, the associated high electric demands have prohibited widespread implementation in what is typically already a fully subscribed power generation and distribution system. Recent advances in CEA technologies as well as renewable power generation, storage, and micro-grid management are increasing system efficiency and expanding the possibilities for enhancing community supporting infrastructure without increasing demands for outside supplied fuels. We will present examples of how new lighting, nutrient delivery, and energy management and control systems can enable significant increases in food production efficiency while maintaining high yields in CEA. Examples from Alaskan communities where initial incorporation of renewable power generation, energy storage and grid management techniques have already reduced diesel fuel consumption for electric generation by more than 40% and expanded grid capacity will be presented. We will discuss how renewable power generation, efficient grid management to extract maximum community service per kW, and novel energy storage approaches can expand the food production, water supply, waste treatment, sanitation and other community support services without traditional increases of consumable fuels supplied from outside the community. These capabilities offer communities with a range of choices to enhance their communities. The examples represent a synergy of technology advancement efforts to develop sustainable community support systems for future space-based human habitats and practical implementation of infrastructure components to increase efficiency and enhance health and well being in remote communities today and tomorrow.

  2. Designing Dual-Active Bridge (DAB) converter for energy storage/recovery systems in a lighting smart grid context

    OpenAIRE

    Rico Secades, Manuel; García Llera, Daniel; López Corominas, Emilio Ramón; Calleja Rodríguez, Antonio Javier

    2014-01-01

    Lighting Systems are suffering and important evolution with the introduction of LED lighting systems with new strategies of energy savings, incorporation of renewable energy sources and optionally a bidirectional interconnection with the mains (AC grid or DC interconnection bus). Lighting Systems are moving to Lighting Smart Grids and step by step integrating in Smart City strategies. In this context design of modular and efficient energy storage/recovery systems are gaining importance lookin...

  3. Geospatial Information Service System Based on GeoSOT Grid & Encoding

    Directory of Open Access Journals (Sweden)

    LI Shizhong

    2016-12-01

    Full Text Available With the rapid development of the space and earth observation technology, it is important to establish a multi-source, multi-scale and unified cross-platform reference for global data. In practice, the production and maintenance of geospatial data are scattered in different units, and the standard of the data grid varies between departments and systems. All these bring out the disunity of standards among different historical periods or orgnizations. Aiming at geospatial information security library for the national high resolution earth observation, there are some demands for global display, associated retrieval and template applications and other integrated services for geospatial data. Based on GeoSOT grid and encoding theory system, "geospatial information security library information of globally unified grid encoding management" data subdivision organization solutions have been proposed; system-level analyses, researches and designs have been carried out. The experimental results show that the data organization and management method based on GeoSOT can significantly improve the overall efficiency of the geospatial information security service system.

  4. Smart Grid as Multi-layer Interacting System for Complex Decision Makings

    Science.gov (United States)

    Bompard, Ettore; Han, Bei; Masera, Marcelo; Pons, Enrico

    This chapter presents an approach to the analysis of Smart Grids based on a multi-layer representation of their technical, cyber, social and decision-making aspects, as well as the related environmental constraints. In the Smart Grid paradigm, self-interested active customers (prosumers), system operators and market players interact among themselves making use of an extensive cyber infrastructure. In addition, policy decision makers define regulations, incentives and constraints to drive the behavior of the competing operators and prosumers, with the objective of ensuring the global desired performance (e.g. system stability, fair prices). For these reasons, the policy decision making is more complicated than in traditional power systems, and needs proper modeling and simulation tools for assessing "in vitro" and ex-ante the possible impacts of the decisions assumed. In this chapter, we consider the smart grids as multi-layered interacting complex systems. The intricacy of the framework, characterized by several interacting layers, cannot be captured by closed-form mathematical models. Therefore, a new approach using Multi Agent Simulation is described. With case studies we provide some indications about how to develop agent-based simulation tools presenting some preliminary examples.

  5. Development of JPSS VIIRS Global Gridded Vegetation Index products for NOAA NCEP Environmental Modeling Systems

    Science.gov (United States)

    Vargas, Marco; Miura, Tomoaki; Csiszar, Ivan; Zheng, Weizhong; Wu, Yihua; Ek, Michael

    2017-04-01

    The first Joint Polar Satellite System (JPSS) mission, the Suomi National Polar-orbiting Partnership (S-NPP) satellite, was successfully launched in October, 2011, and it will be followed by JPSS-1, slated for launch in 2017. JPSS provides operational continuity of satellite-based observations and products for NOAA's Polar Operational Environmental Satellites (POES). Vegetation products derived from satellite measurements are used for weather forecasting, land modeling, climate research, and monitoring the environment including drought, the health of ecosystems, crop monitoring and forest fires. The operationally produced S-NPP VIIRS Vegetation Index (VI) Environmental Data Record (EDR) includes two vegetation indices: the Top of the Atmosphere (TOA) Normalized Difference Vegetation Index (NDVI), and the Top of the Canopy (TOC) Enhanced Vegetation Index (EVI). For JPSS-1, the S-NPP Vegetation Index EDR algorithm has been updated to include the TOC NDV. The current JPSS operational VI products are generated in granule style at 375 meter resolution at nadir, but these products in granule format cannot be ingested into NOAA operational monitoring and decision making systems. For that reason, the NOAA JPSS Land Team is developing a new global gridded Vegetation Index (VI) product suite for operational use by the NOAA National Centers for Environmental Prediction (NCEP). The new global gridded VIs will be used in the Multi-Physics (MP) version of the Noah land surface model (Noah-MP) in NCEP NOAA Environmental Modeling System (NEMS) for plant growth and data assimilation and to describe vegetation coverage and density in order to model the correct surface energy partition. The new VI 4km resolution global gridded products (TOA NDVI, TOC NDVI and TOC EVI) are being designed to meet the needs of directly ingesting vegetation index variables without the need to develop local gridding and compositing procedures. These VI products will be consistent with the already

  6. Single Phase PV Grid-Connected in Smart Household Energy System with Anticipation on Fault Conditions

    Directory of Open Access Journals (Sweden)

    Feri Yusivar

    2014-02-01

    Full Text Available This paper proposes an algorithm of Smart household energy systems to anticipate fault conditions in power system grid. Single phase PV grid-connected in smart household energy system is a smart system that determines electrical supply conditions to the load in residential electrical system. The smart system is consisted of two voltage source, conventional electricity system from national electricity provider as preferred source and photovoltaic as the alternative source. In smart system, fault conditions can be anticipated by selecting the appropriate voltage sources to supply the load. The condition of smart system can be described in power flow regulation to the load by detection and identification of amplitude, phase angle, and frequency of the voltage source compared to the system reference. The system mechanism is based on detection of voltage source using static transfer switch (STS with phase locked loop (PLL as voltage detection algorithm which output is used to determine decision logic algorithm for switching conditions. The results show that conditions of smart power system flow can be obtained based on voltage source selection in decision logic when fault condition occurs.

  7. Optimal Power System and Grid Interface Design Considerations for the CLICs Klystron Modulators

    CERN Document Server

    Marija, Jankovic; Jon, Clare; Pat, Wheeler; Davide, Aguglia

    2015-01-01

    The Compact Linear Collider (CLIC) is an electron-positron collider under study at CERN with the aim to explore the next generation of high precision/high energy particles physics. The CLIC’s drive beams will be accelerated by approximately 1300 klystrons, requiring highly efficient and controllable solid state capacitor discharge modulators. Capacitor charger specifications include the requirement to mask the pulsed effect of the load from the utility grid, ensure maximum power quality, control the derived DC voltage precisely (to maximize accuracy for the modulators being implemented), and achieve high efficiency and operability of the overall power system. This paper presents the work carried out on the power system interface for the CLIC facility. In particular it discusses the challenges on the utility interface and analysis of the grid interface converters with regards to required functionality, efficiency, and control methodologies.

  8. Development of a Microcontroller-based Battery Charge Controller for an Off-grid Photovoltaic System

    Science.gov (United States)

    Rina, Z. S.; Amin, N. A. M.; Hashim, M. S. M.; Majid, M. S. A.; Rojan, M. A.; Zaman, I.

    2017-08-01

    A development of a microcontroller-based charge controller for a 12V battery has been explained in this paper. The system is designed based on a novel algorithm to couple existing solar photovoltaic (PV) charging and main grid supply charging power source. One of the main purposes of the hybrid charge controller is to supply a continuous charging power source to the battery. Furthermore, the hybrid charge controller was developed to shorten the battery charging time taken. The algorithm is programmed in an Arduino Uno R3 microcontroller that monitors the battery voltage and generates appropriate commands for the charging power source selection. The solar energy is utilized whenever the solar irradiation is high. The main grid supply will be only consumed whenever the solar irradiation is low. This system ensures continuous charging power supply and faster charging of the battery.

  9. A Review of Systems and Technologies for Smart Homes and Smart Grids

    Directory of Open Access Journals (Sweden)

    Gabriele Lobaccaro

    2016-05-01

    Full Text Available In the actual era of smart homes and smart grids, advanced technological systems that allow the automation of domestic tasks are developing rapidly. There are numerous technologies and applications that can be installed in smart homes today. They enable communication between home appliances and users, and enhance home appliances’ automation, monitoring and remote control capabilities. This review article, by introducing the concept of the smart home and the advent of the smart grid, investigates technologies for smart homes. The technical descriptions of the systems are presented and point out advantages and disadvantages of each technology and product today available on the market. Barriers, challenges, benefits and future trends regarding the technologies and the role of users have also been discussed.

  10. Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System

    Energy Technology Data Exchange (ETDEWEB)

    Agamy, Mohammed [GE Global Research Center, Niskayuna, NY (United States)

    2015-10-27

    The “Module Embedded Micro-inverter Smart Grid Ready Residential Solar Electric System” program is focused on developing innovative concepts for residential photovoltaic (PV) systems with the following objectives: to create an Innovative micro-inverter topology that reduces the cost from the best in class micro-inverter and provides high efficiency (>96% CEC - California Energy Commission), and 25+ year warranty, as well as reactive power support; integrate micro-inverter and PV module to reduce system price by at least $0.25/W through a) accentuating dual use of the module metal frame as a large area heat spreader reducing operating temperature, and b) eliminating redundant wiring and connectors; and create micro-inverter controller handles smart grid and safety functions to simplify implementation and reduce cost.

  11. SYNCHRONIZATION OF NATIONAL GRID NETWORK WITH THE ELECTRICITY SHIPS NETWORK IN THE "SHORE TO SHIP" SYSTEM

    Directory of Open Access Journals (Sweden)

    Dariusz TARNAPOWICZ

    2013-07-01

    Full Text Available ‘Shore to ship’ system – ships’ power supply from the local electrical substations – is one of the effective ways to limit the negative impact of the ships lying in ports on the environment. Energy infrastructure of the port installation necessary to provide ships with power supply has to be designed so that different types of ships can use it. The important issue concerning ‘shore to ship’ system is the quality of power supply. This can be achieved via sustaining continuity of power supply while switching from the ships’ electrical network over to the national grid. In this article the author presents the way of synchronizing the national grid with the ships’ electrical network during ship’s lying in port. Such synchronization would allow for uninterruptible work of the ship’s electrical devices.

  12. A Multi-layer, Hierarchical Information Management System for the Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Ning; Du, Pengwei; Paulson, Patrick R.; Greitzer, Frank L.; Guo, Xinxin; Hadley, Mark D.

    2011-10-10

    This paper presents the modeling approach, methodologies, and initial results of setting up a multi-layer, hierarchical information management system (IMS) for the smart grid. The IMS allows its users to analyze the data collected by multiple control and communication networks to characterize the states of the smart grid. Abnormal, corrupted, or erroneous measurement data and outliers are detected and analyzed to identify whether they are caused by random equipment failures, unintentional human errors, or deliberate tempering attempts. Data collected from different information networks are crosschecked for data integrity based on redundancy, dependency, correlation, or cross-correlations, which reveal the interdependency between data sets. A hierarchically structured reasoning mechanism is used to rank possible causes of an event to aid the system operators to proactively respond or provide mitigation recommendations to remove or neutralize the threats. The model provides satisfactory performance on identifying the cause of an event and significantly reduces the need of processing myriads of data collected.

  13. Monitoring of the electrical parameters in off-grid solar power system

    Science.gov (United States)

    Idzkowski, Adam; Leoniuk, Katarzyna; Walendziuk, Wojciech

    2016-09-01

    The aim of this work was to make a monitoring dedicated to an off-grid installation. A laboratory set, which was built for that purpose, was equipped with a PV panel, a battery, a charge controller and a load. Additionally, to monitor electrical parameters from this installation there were used: LabJack module (data acquisition card), measuring module (self-built) and a computer with a program, which allows to measure and present the off-grid installation parameters. The program was made in G language using LabVIEW software. The designed system enables analyzing the currents and voltages of PV panel, battery and load. It makes also possible to visualize them on charts and to make reports from registered data. The monitoring system was also verified by a laboratory test and in real conditions. The results of this verification are also presented.

  14. Regulating Future Offshore Grids: Economic Impact Analysis on Wind Parks and Transmission System Operators

    DEFF Research Database (Denmark)

    Kitzing, Lena; Schröder, Sascha Thorsten

    , for example in the price premium level, investment incentives could either be diminished or the wind park could incur windfall profits. Both cases are socio-economically suboptimal as they may pose additional cost to the system. Policy makers should consider these findings when designing the regulatory regime...... the respective countries. This study focuses on how investors in wind parks and transmission systems are affected by the choice of regulatory regime in offshore grids with one to four countries connected. In order to capture the uncertainties related to the exposure to market prices as well as risks related...... to line failures, we develop a stochastic model for an exemplary wind park and offshore grid. This yields the real option values of operational flexibility from additional connections. Simulation results show that the choice of regulatory regime, including market access and pricing rules, can have...

  15. `imaka - a ground-layer adaptive optics system on Maunakea

    CERN Document Server

    Chun, Mark; Toomey, Douglas; Lu, Jessica; Service, Max; Baranec, Christoph; Thibault, Simon; Brousseau, Denis; Hayano, Yutaka; Oya, Shin; Santi, Shane; Kingery, Christopher; Loss, Keith; Gardiner, John; Steele, Brad

    2016-01-01

    We present the integration status for `imaka, the ground-layer adaptive optics (GLAO) system on the University of Hawaii 2.2-meter telescope on Maunakea, Hawaii. This wide-field GLAO pathfinder system exploits Maunakea's highly confined ground layer and weak free-atmosphere to push the corrected field of view to ~1/3 of a degree, an areal field approaching an order of magnitude larger than any existing or planned GLAO system, with a FWHM ~ 0.33 arcseconds in the visible and near infrared. We discuss the unique design aspects of the instrument, the driving science cases and how they impact the system, and how we will demonstrate these cases on the sky.

  16. Experimental optimization of the FireFly 600 photovoltaic off-grid system.

    Energy Technology Data Exchange (ETDEWEB)

    Boyson, William Earl; Orozco, Ron (Energia Total, Ltd., Corrales, NM); Ralph, Mark E.; Brown, Marlene Laura; King, David L.; Hund, Thomas D.

    2003-10-01

    A comprehensive evaluation and experimental optimization of the FireFly{trademark} 600 off-grid photovoltaic system manufactured by Energia Total, Ltd. was conducted at Sandia National Laboratories in May and June of 2001. This evaluation was conducted at the request of the manufacturer and addressed performance of individual system components, overall system functionality and performance, safety concerns, and compliance with applicable codes and standards. A primary goal of the effort was to identify areas for improvement in performance, reliability, and safety. New system test procedures were developed during the effort.

  17. Vehicle-to-Grid for islanded power system operation in Bornholm

    DEFF Research Database (Denmark)

    Pillai, Jayakrishnan Radhakrishna; Bak-Jensen, Birgitte

    2010-01-01

    a model of an aggregated electric vehicle based battery storage to support an isolated power system operating with a large wind power penetration in the Danish island of Bornholm. From the simulation results, the EV battery storages represented by the V2G systems are able to integrate more fluctuating......Vehicle-to-Grid (V2G) systems are an emerging concept of utilizing the battery storage of electric vehicles (EVs) for providing power system regulation services. This technology could be used to balance the variable electricity generated from various renewable energy sources. This article considers...

  18. Z-Source-Inverter-Based Flexible Distributed Generation System Solution for Grid Power Quality Improvement

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Vilathgamuwa, D. M.; Loh, Poh Chiang

    2009-01-01

    Distributed generation (DG) systems are usually connected to the grid using power electronic converters. Power delivered from such DG sources depends on factors like energy availability and load demand. The converters used in power conversion do not operate with their full capacity all the time......-stage buck-boost inverter, recently proposed Z-source inverter (ZSI) is a good candidate for future DG systems. This paper presents a controller design for a ZSI-based DG system to improve power quality of distribution systems. The proposed control method is tested with simulation results obtained using...

  19. Smart buildings in the smart grid: Contract-based design of an integrated energy management system

    OpenAIRE

    Maasoumy, M; Nuzzo, P; Sangiovanni-Vincentelli, A.

    2015-01-01

    © Springer-Verlag Berlin Heidelberg 2015. In a supply-following “smart” grid scenario, buildings can exploit remotely controllable thermostats and “smart” meters to communicate with energy providers, trade energy in real-time and offer frequency regulation services, by leveraging the flexibility in the energy consumption of their heating, ventilation and air conditioning (HVAC) systems. The realization of such a scenario is, however, strongly dependent on our ability to radically re-think the...

  20. Electrical PV array reconfiguration strategy for energy extraction improvement in grid-connected PV systems

    OpenAIRE

    2009-01-01

    This paper applies a dynamical electrical array reconfiguration (EAR) strategy on the photovoltaic (PV) generator of a grid-connected PV system based on a plant-oriented configuration, in order to improve its energy production when the operating conditions of the solar panels are different. The EAR strategy is carried out by inserting a controllable switching matrix between the PV generator and the central inverter, which allows the electrical reconnection of the available PV modules. A...