WorldWideScience

Sample records for gross beta counting

  1. A Method Validation for Determination of Gross Alpha and Gross Beta in Water Sample Using Low Background Gross Alpha/ Beta Counting System

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2016-01-01

    Method validation (MV) for the measurement of gross alpha and gross beta activity in water (drinking, mineral and environmental) samples using Low Background Gross Alpha/ Beta Counting System was performed to characterize precision, accuracy and reliable results. The main objective of this assignment is to ensure that both the instrument and method always good performed and resulting accuracy and reliable results. Generally, almost the results of estimated RSD, z-score and U_s_c_o_r_e were reliable which are recorded as ≤30 %, less than 2 and less than 1.5, respectively. Minimum Detected Activity (MDA) was estimated based on the counting time of 100 minutes and present background counting value of gross alpha (0.01 - 0.35 cpm) and gross beta (0.50 - 2.18 cpm). Estimated Detection Limit (DL) was 0.1 Bq/ L for gross alpha and 0.2 Bq/ L for gross beta and expended uncertainty was relatively small of 9.77 % for gross alpha and 10.57 % for gross beta. Align with that, background counting for gross alpha and gross beta was ranged of 0.01 - 0.35 cpm and 0.50 - 2.18 cpm, respectively. While, sample volume was set at minimum of 500 mL and maximum of 2000 mL. These proven the accuracy and precision result that are generated from developed method/ technique is satisfactory and method is recommended to be used. Therefore, it can be concluded that the MV found no doubtful on the ability of the developed method. The test result showed the method is suitable for all types of water samples which are contained several radionuclides and elements as well as any impurities that interfere the measurement analysis of gross alpha and gross beta. (author)

  2. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  3. Gross alpha and gross beta determination in surface and groundwater water by liquid scintillation counting (LSC)

    International Nuclear Information System (INIS)

    Faria, Ligia S.; Moreira, Rubens M.

    2013-01-01

    The present study has used 40 samples of groundwater and surface water collected at four different sites along the period of one year in Brumadinho and Nova Lima, two municipalities in the State of Minas Gerais, Brazil, as part of a more extensive study aiming at determination of the natural radioactivity in the water used for domestic use. These two sites are inside an Environmental Protection Area is located in a region of very intensive iron ore exploration. In addition of mineral resources, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium. Radioactivity levels were determined via liquid scintillation counting (LSC), a fast and high counting efficiency method that can be advantageously employed to determine gross alpha and gross beta activity in liquid samples. Previously to gross alpha and gross beta counting the samples were acidified with concentrated HNO 3 in the field. The technique involved a pre-concentration of the sample to obtain a low detection limit. Specific details of the employed methodology are commented. The results showed that concentrations of gross alpha natural activity and gross beta values ranged from less than the detection limit of the equipment (0.03 Bq.L -1 ) to 0.275 ± 0.05 Bq.L -1 for gross alpha. As regards gross beta, all samples were below the limit of detection. (author)

  4. Determination of gross gamma and gross beta activities in liquid effluent samples. Phase I

    International Nuclear Information System (INIS)

    Curtis, K.E.; Sood, S.P.

    1985-08-01

    Several inadequacies in the presently used procedures for gross gamma and gross beta measurements in aqueous wastes have been identified. Both the presence of suspended particulate activity and the use of cesium-137 as a calibration standard can cause gross gamma measurements to overestimate the actual activity in the sample. At the same time, sample preparation for the determination of gross beta activities causes large losses of radioiodine before the measurement step and the presence of solid material can cause a serious decrease in the beta counting efficiency. A combination of these errors could result in large discrepancies between the results obtained by the two measurement methods. Improved procedures are required to overcome these problems

  5. Innovative procedure for the determination of gross-alpha/gross-beta activities in drinking water

    International Nuclear Information System (INIS)

    Wisser, S.; Frenzel, E.; Dittmer, M.

    2006-01-01

    An alternative sample preparation method for the determination of gross-alpha/beta activity concentrations in drinking water is introduced in this paper. After the freeze-drying of tap water samples, determination by liquid scintillation counting can be applied utilizing alpha/beta separation. It has been shown that there is no adsorption or loss of solid radionuclides during the freeze-drying procedure. However, the samples have to be measured quickly after the preparation since the ingrowth of daughter isotopes negatively effects the measurement. The limits of detection for gross-alpha and gross-beta activity are in the range 25-210 mBq/l, respectively, for a measurement time of only 8-9 h

  6. Monitoring of gross alpha, gross beta and tritium activities in portuguese drinking waters

    International Nuclear Information System (INIS)

    Lopes, I.; Madruga, M.J.; Ferrador, G.O.; Sequeira, M.M.; Oliveira, E.J.; Gomes, A.R.; Rodrigues, F.D.; Carvalho, F.P.

    2006-01-01

    The gross beta and tritium activities in the forty Portuguese drinking waters analyzed using the ISO standard methods (Portuguese Guidelines) are below the guidance levels proposed in the Portuguese Drinking Water Quality Guidelines. In what concerns the gross alpha activity only 18% exceeded the recommended level. In general, it can be concluded that the ingestion of these drinking waters does not create a radiological hazard to the human consumption, however, more detailed analyses will be necessary mainly the determinations of the individual alpha emitters radionuclide concentrations. The minimum gross alpha and gross beta detectable activities by L.S.C. methodology are higher than for the proportional counting technique (ISO method). Higher concentration factors will be needed to reach lower required detection limits. (authors)

  7. Measurement of Gross Alpha and Gross Beta Radioactivity of River Yobe, North Eastern Nigeria

    International Nuclear Information System (INIS)

    Abba, H. T.; Sadiq, U.; Adeyemo, D. J.

    2013-01-01

    Measurement of the gross alpha and gross beta radioactivity of River Yobe has been carried out. Fifteen samples of the river water were collected from the farming, fishing, domestic/livestock and control areas along the river and were analyzed using desktop alpha/beta (MPC 2000- DP) counting system. The count results show the average alpha activities in farming, fishing, domestic/livestock and control areas are 0.207±0.082, 0.257±0.13, 0.437±0.315 and 0.237±0.10 Bq L -1 , respectively. The average beta activities in the four areas are 0.813±0.122, 0.308±0.0145, 0.563±0.230 and 0.225±0.0096 Bq L -1 , respectively. The overall results show that the alpha and beta activities in the four areas are far below the practical screening level of radioactivity in drinking water of 0.5 Bq L -1 for alpha and 1 Bq L -1 for beta recommended by CEC-FAO and WHO and therefore may not pose any serious detrimental health side-effects to the public users of the river.

  8. A survey of gross alpha and gross beta activity in soil samples in Kinta District, Perak, Malaysia

    International Nuclear Information System (INIS)

    Lee, Siak Kuan; Wagiran, Husin; Ramli, Ahmad Termizi

    2014-01-01

    The objective of this study was to determine the gross alpha and gross beta activity concentrations from the different soil types found in the Kinta District, Perak, Malaysia. A total of 128 soil samples were collected and their dose rates were measured 1 m above the ground. Gross alpha and gross beta activity measurements were carried out using gas flow proportional counter, Tennelec Series 5 LB5500 Automatic Low Background Counting System. The alpha activity concentration ranged from 15 to 9634 Bq kg -1 with a mean value of 1558±121 Bq kg -1 . The beta activity concentration ranged from 142 to 6173 Bq kg -1 with a mean value of 1112±32 Bq kg -1 . High alpha and beta activity concentrations are from the same soil type. The results of the analysis show a strong correlation between the gross alpha activity concentration and dose rate (R = 0.92). The data obtained can be used as a database for each soil type. (authors)

  9. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  10. Rapid determination of gross alpha and beta activity in seafood utilizing microwave digestion and liquid scintillation counting

    International Nuclear Information System (INIS)

    Daniel Sas; Jiri Janda; Alena Tokarova

    2015-01-01

    This paper describes a method for rapid determination of gross alpha and beta activity in seafood using liquid scintillation counting and microwave digestion for fast sample decomposition. The general group of seafood was divided into two groups based on its structure, whether it has shell or not. The selected group of radionuclides was chosen with respect to military significance, radiotoxicity, and possibility of potential misuse. 90 Sr and 239 Pu were selected as model radionuclides. (author)

  11. Influence of crosstalk phenomenon on the measurement of gross alpha and gross beta radioactivity in drinking water

    International Nuclear Information System (INIS)

    Gerilemandahu; Haribala; Xu Xiao; Shen Na; Sai Wenga; Bai Guilin; Wang Chengguo

    2014-01-01

    Objective: To study the influence of crosstalk phenomenon on the measurement of gross radioactivity in drinking water. Methods: The gross activity in different standard materials with different thickness and area was measured using national standard method. Results: There was no obvious change in crosstalk factor with the increase of "2"4"1Am powder amount in the measurement, whereas the larger amount of uranium used might lead to larger crosstalk factor. The different measurement channels resulted in different crosstalk factors. The influence of beta radioactivity on alpha radioactivity measurement was significant. On the contrary, the alpha-to-beta crosstalk factor was negligible. The area of sample plate imposed no significant influence on crosstalk factor. Conclusions: The gross beta activity can be corrected to decrease the influence of alpha radioactivity using powder standard samples, when simultaneous alpha and beta counting mode is applied in measurement grass radioactivity in drinking water. (authors)

  12. Estimation of low level gross alpha activities in the radioactive effluent using liquid scintillation counting technique

    International Nuclear Information System (INIS)

    Bhade, Sonali P.D.; Johnson, Bella E.; Singh, Sanjay; Babu, D.A.R.

    2012-01-01

    A technique has been developed for simultaneous measurement of gross alpha and gross beta activity concentration in low level liquid effluent samples in presence of higher activity concentrations of tritium. For this purpose, alpha beta discriminating Pulse Shape Analysis Liquid Scintillation Counting (LSC) technique was used. Main advantages of this technique are easy sample preparation, rapid measurement and higher sensitivity. The calibration methodology for Quantulus1220 LSC based on PSA technique using 241 Am and 90 Sr/ 90 Y as alpha and beta standards respectively was described in detail. LSC technique was validated by measuring alpha and beta activity concentrations in test samples with known amount of 241 Am and 90 Sr/ 90 Y activities spiked in distilled water. The results obtained by LSC technique were compared with conventional planchet counting methods such as ZnS(Ag) and end window GM detectors. The gross alpha and gross beta activity concentrations in spiked samples, obtained by LSC technique were found to be within ±5% of the reference values. (author)

  13. Gross alpha and beta activities in Tunisian mineral water

    International Nuclear Information System (INIS)

    Hamrouni Benbelgacem, Samar

    2011-01-01

    The quality of natural mineral water is a universal health problem seeing its vital importance. This problem is related to the presence of the radionuclides since this water is coming from underground, during their circulation it dissolves and conveys the radionuclides which are present in the earth's crust. This problem which leads to the contamination of the mineral water urged the World Health Organization to set standards and to recommend the respect of the median values of the activities alpha and beta within the framework of the man protection against this internal exhibition. Concerning the radiological quality of Tunisian mineral water studied in this project, we showed, by using the gross alpha and beta activities counting, that this water is specific to human consumption since their gross alpha and beta activities do not forward any risk on health.

  14. Characterization Of The Alpha/Beta Counting System Type MPC 9400 And Its Utilization

    International Nuclear Information System (INIS)

    Makhsum; Sutarman; Fikri, Hanif; Handoko, Djati

    2000-01-01

    Have been carried out the experiment to determine the operation voltage, instrument stability, counting efficiency, figure of merit, and minimum detectable activity. This instrument used to count gross alpha and gross beta. This instrument belongs good stability at the confidence level of 95 % and the background count that was 0,144 cpm for alpha and 22,65 cpm for beta. The counting efficiency was 27,41 % (electrodeposition of Am-241), 6,57 % (deposition of Am-241), 51,82 % (deposition of Sr-90). The limit of detectable activity was 1,04 x 10 exp.-2 Bq (electrodeposition of Am-241), 4,35 x 10 exp.-2 Bq (% deposition of Sr 90)

  15. The influence of the calibration standard and the chemical composition of the water samples residue in the counting efficiency of proportional detectors for gross alpha and beta counting. Application on the radiologic control of the IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Santos, Cecilia Martins

    2003-01-01

    In this work the efficiency calibration curves of thin-window and low background gas-flow proportional counters were determined for calibration standards with different energies and different absorber thicknesses. For the gross alpha counting we have used 241 Am and natural uranium standards and for the gross beta counting we have used 90 Sr/ 90 Y and 137 Cs standards in residue thicknesses ranging from 0 to approximately 18 mg/cm 2 . These sample thicknesses were increased with a previously determined salted solution prepared simulating the chemical composition of the underground water of IPEN The counting efficiency for alpha emitters ranged from 0,273 +- 0,038 for a weightless residue to only 0,015 +- 0,002 in a planchet containing 15 mg/cm 2 of residue for 241 Am standard. For natural uranium standard the efficiency ranged from 0,322 +- 0,030 for a weightless residue to 0,023 +- 0,003 in a planchet containing 14,5 mg/cm 2 of residue. The counting efficiency for beta emitters ranged from 0,430 +- 0,036 for a weightless residue to 0,247 +- 0,020 in a planchet containing 17 mg/cm 2 of residue for 137 Cs standard. For 90 Sr/ 90 Y standard the efficiency ranged from 0,489 +- 0,041 for a weightless residue to 0,323 +- 0,026 in a planchet containing 18 mg/cm 2 of residue. Results make evident the counting efficiency variation with the alpha or beta emitters energies and the thickness of the water samples residue. So, the calibration standard, the thickness and the chemical composition of the residue must always be considered in the gross alpha and beta radioactivity determination in water samples. (author)

  16. Measurement of gross alpha, gross beta, radon and radium activity concentrations in aqueous samples using liquid scintillation technique

    International Nuclear Information System (INIS)

    Zaini Hamzah; Ahmad Saat; Masitah Alias; Siti Afiqah Abdul Rahman; Mohamed Kasim; Abdul Kadir Ishak

    2011-01-01

    Recently, Malaysia has taken a positive step toward providing a better water quality by introducing more water quality parameters into its Water Quality Standard. With regard to the natural radionuclides that may present in the water, 3 parameters were introduced that is gross alpha, gross beta and radium which need to be measured and cannot exceed 0.1, 1.0 and 1.0 Bq/ L respectively. This study was conducted to develop a more practical method in measuring these parameters in aqueous environmental samples. Besides having a lot of former tin mining areas, some part of Malaysia is located on the granitic rock which also contributes to a certain extent the amount of natural radionuclides such as uranium and thorium. For all we know these two radionuclides are the origin of other radionuclides being produced from their decay series. The State of Kelantan was chosen as the study area, where the water samples were collected from various part of the Kelantan River. 25 liters of samples were collected, acidify to pH 2 and filtered before the analysis. Measurement of these parameters was done using liquid scintillation counter (LSC). The LSC was set up to the optimum discriminator level and counting was done using alpha-beta mode. The results show that gross alpha and beta can be measured using scintillation cocktail and radium and radon using extraction method. The results for gross alpha, gross beta, 222 Ra and 226 Ra are 0.39-6.42, 0.66-16.18, 0.40-4.65 and 0.05-0.56 Bq/ L. MDA for gross alpha, gross beta and radium is 0.03, 0.08 and 0.00035 Bq/ L respectively. (Author)

  17. Determination of gross alpha and gross beta in soil around repository facility at Bukit Kledang, Perak, Malaysia

    Science.gov (United States)

    Adziz, Mohd Izwan Abdul; Siong, Khoo Kok

    2018-04-01

    Recently, the Long Term Storage Facility (LTSF) in Bukit Kledang, Perak, Malaysia, has been upgraded to repository facility upon the completion of decontamination and decommissioning (D&D) process. Thorium waste and contaminated material that may contain some minor amounts of thorium hydroxide were disposed in this facility. This study is conducted to determine the concentrations of gross alpha and gross beta radioactivities in soil samples collected around the repository facility. A total of 12 soil samples were collected consisting 10 samples from around the facility and 2 samples from selected residential area near the facility. In addition, the respective dose rates were measured 5 cm and 1 m above the ground by using survey meter with Geiger Muller (GM) detector and Sodium Iodide (NaI) detector. Soil samples were collected using hand auger and then were taken back to the laboratory for further analysis. Samples were cleaned, dried, pulverized and sieved prior to analysis. Gross alpha and gross beta activity measurements were carried out using gas flow proportional counter, Canberra Series 5 XLB - Automatic Low Background Alpha and Beta Counting System. The obtained results show that, the gross alpha and gross beta activity concentration ranged from 1.55 to 5.34 Bq/g with a mean value of 3.47 ± 0.09 Bq/g and 1.64 to 5.78 Bq/g with a mean value of 3.49 ± 0.09 Bq/g, respectively. These results can be used as an additional data to represent terrestrial radioactivity baseline data for Malaysia environment. This estimation will also serve as baseline for detection of any future related activities of contamination especially around the repository facility area.

  18. Measurement of gross alpha and gross beta activity concentrations in human tooth

    International Nuclear Information System (INIS)

    Soeguet, Omer; Aydin, Mehmet Fatih; Kuecuekoender, Erdal; Zorer, Ozlem Selcuk; Dogru, Mahmut

    2010-01-01

    The gross alpha and gross beta activity concentrations were measured in human tooth taken from 3 to 6 age-groups to 40 and over ones. Accumulated teeth samples are investigated in two groups as under and above 18 years. The gross alpha and beta radioactivity of human tooth samples was measured by using a gas-flow proportional counter (PIC-MPC 9604-α/β counter). In tooth samples, for female age-groups, the obtained results show that the mean gross alpha and gross beta activity concentrations varied between 0.534-0.203 and 0.010-0.453 Bq g -1 and the same concentrations for male age-groups varied between 0.009-1.168 and 0.071-0.204 Bq g -1 , respectively.

  19. Requirement of radiochemical recovery determination for gross alpha and gross beta estimation in drinking water

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Hegde, A.G.

    2010-01-01

    Presence of radionuclides in drinking water which emits Alpha and Beta particles are the potential sources of internal exposure in drinking water. Gross alpha and gross beta determination in drinking water and packaged drinking water (PDW) as per BIS (Bureau of Indian standards) standards is discussed here. The methods have been tested to account for losses in the radiochemical procedures using radionuclides such as 137 Cs, 90 Sr, 226 Ra, 239 Pu, 243 Am, 232 U. The methods have also been validated in an IAEA proficiency test conducted during 2009. Monitoring of gross alpha and gross beta activity observed in drinking water/packaged drinking water from various states of India were within the limits set by BIS. Average radiochemical recoveries of 84% and 63% were obtained for gross α and gross β respectively. (author)

  20. Measurement of gross beta radioactivity in high-level liquid waste

    International Nuclear Information System (INIS)

    Lu Feng; Lin Cansheng; Zhang Xianzi; Chen Guoan; Zhang Chonghai

    1992-01-01

    Using beta plastic scintillation counter of low level background, gross beta radioactivity of twelve samples for high-level liquid waste is determined directly. Beta efficiency curves of plastic scintillation counter for four mass thickness are calibrated in advance. Determining gross beta radioactivity, gross efficiency of the scintillation counter for various energy beta ray is calculated via weighted mean method with the ratio of radioactivity for each nuclide. The ratio of radioactivity for nuclides which have gamma disintegration is determined in terms of the radioactivity measured by gamma spectrometer. The ratio of the radioactivity for 90 Sr which has purity beta disintegration is calculated in terms of half life time approximation. The ratio of the radioactivity for 147 Pm which also has purity disintegration is calculated by means of apparent cooling-time approximation. The uncertainty of results for the present work is about +-15%

  1. Preparation and validation of gross alpha/beta samples used in EML's quality assessment program

    International Nuclear Information System (INIS)

    Scarpitta, S.C.

    1997-10-01

    A set of water and filter samples have been incorporated into the existing Environmental Measurements Laboratory's (EML) Quality Assessment Program (QAP) for gross alpha/beta determinations by participating DOE laboratories. The participating laboratories are evaluated by comparing their results with the EML value. The preferred EML method for measuring water and filter samples, described in this report, uses gas flow proportional counters with 2 in. detectors. Procedures for sample preparation, quality control and instrument calibration are presented. Liquid scintillation (LS) counting is an alternative technique that is suitable for quantifying both the alpha ( 241 Am, 230 Th and 238 Pu) and beta ( 90 Sr/ 90 Y) activity concentrations in the solutions used to prepare the QAP water and air filter samples. Three LS counting techniques (Cerenkov, dual dpm and full spectrum analysis) are compared. These techniques may be used to validate the activity concentrations of each component in the alpha/beta solution before the QAP samples are actually prepared

  2. Beta-decay rate and beta-delayed neutron emission probability of improved gross theory

    Science.gov (United States)

    Koura, Hiroyuki

    2014-09-01

    A theoretical study has been carried out on beta-decay rate and beta-delayed neutron emission probability. The gross theory of the beta decay is based on an idea of the sum rule of the beta-decay strength function, and has succeeded in describing beta-decay half-lives of nuclei overall nuclear mass region. The gross theory includes not only the allowed transition as the Fermi and the Gamow-Teller, but also the first-forbidden transition. In this work, some improvements are introduced as the nuclear shell correction on nuclear level densities and the nuclear deformation for nuclear strength functions, those effects were not included in the original gross theory. The shell energy and the nuclear deformation for unmeasured nuclei are adopted from the KTUY nuclear mass formula, which is based on the spherical-basis method. Considering the properties of the integrated Fermi function, we can roughly categorized energy region of excited-state of a daughter nucleus into three regions: a highly-excited energy region, which fully affect a delayed neutron probability, a middle energy region, which is estimated to contribute the decay heat, and a region neighboring the ground-state, which determines the beta-decay rate. Some results will be given in the presentation. A theoretical study has been carried out on beta-decay rate and beta-delayed neutron emission probability. The gross theory of the beta decay is based on an idea of the sum rule of the beta-decay strength function, and has succeeded in describing beta-decay half-lives of nuclei overall nuclear mass region. The gross theory includes not only the allowed transition as the Fermi and the Gamow-Teller, but also the first-forbidden transition. In this work, some improvements are introduced as the nuclear shell correction on nuclear level densities and the nuclear deformation for nuclear strength functions, those effects were not included in the original gross theory. The shell energy and the nuclear deformation for

  3. Standardization and estimation of gross alpha and beta activities for potable water samples in presence of TDS using TDCR based LSA (Hidex 300SL)

    International Nuclear Information System (INIS)

    Gupta, Anil; Lenka, P.; Sahoo, S.K.; Patra, A.C.; Jha, S.K.; Tripathi, R.M.

    2018-01-01

    Quality of water is important in environmental studies because of its daily use for human consumption and an important route of intake for various elements and radionuclides. Therefore radiological quality of drinking water must be ensured. The screening parameter to evaluate the radiological safety of potable water is by estimating gross alpha and gross beta activities with a limit of 0.5 Bq/l and 1 Bq/l respectively. These have been traditionally being done by radiochemical co-precipitation of alpha and beta emitters followed by counting by ZnS(Ag) counter for alpha and gas flow proportional counter for beta. Gross alpha estimation in water samples with high TDS by ZnS(Ag) is difficult and often leads to underestimation of result due to self-absorption of alpha within the residue. This study was carried out to standardize a method to provide rapid results by simultaneously estimating both gross alpha and gross beta activity in the presence of TDS with adequate sensitivity, minimum sample processing

  4. Monitoring of gross beta radioactivities on water sample environment in the surrounding of kartini reactor at 2011

    International Nuclear Information System (INIS)

    Siswanti; Munandar, A. Aris

    2013-01-01

    Measurement of gross beta radioactivities on water environment were done in the PTAPB BATAN has a goal for routine monitoring, with the result that fill RPL has been made and the result equivalented with quality standard were decided by BAPETEN. The water sample taken as much as 2 liter at 18 area were definited on radius 100 m to 5000 m in the surrounding of kartini reactor, vaporin on electric stove till the volume been ± 10 ml, and than pick out to the aluminium planset and drying on hot plate. Sample in the plancet were counted with a Low Background Counter (LBC) for 30 minutes and accounted of gross beta radioactivity water system. The result of gross beta radioactivity water environment at 2011 has a lowest 009, ± 0,06 Bq/I on Tambak Bayan area at june and in the Janti area highest 0,39 ± 0,08 Bq/ at December. The result still under of quality standard were decided by SK BAPETEN. No. 02/Ka- BAPETEN/V-99 is 0,4 Bq/I. (author)

  5. Gross beta determination in drinking water using scintillating fiber array detector.

    Science.gov (United States)

    Lv, Wen-Hui; Yi, Hong-Chang; Liu, Tong-Qing; Zeng, Zhi; Li, Jun-Li; Zhang, Hui; Ma, Hao

    2018-04-04

    A scintillating fiber array detector for measuring gross beta counting is developed to monitor the real-time radioactivity in drinking water. The detector, placed in a stainless-steel tank, consists of 1096 scintillating fibers, both sides of which are connected to a photomultiplier tube. The detector parameters, including working voltage, background counting rate and stability, are tested, and the detection efficiency is calibrated using standard potassium chloride solution. Water samples are measured with the detector and the results are compared with those by evaporation method. The results show consistency with those by evaporation method. The background counting rate of the detector is 38.131 ± 0.005 cps, and the detection efficiency for β particles is 0.37 ± 0.01 cps/(Bq/l). The MDAC of this system can be less than 1.0 Bq/l for β particles in 120 min without pre-concentration. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Optimization of Counting Times, Figure of Merit and Mass Thickness for Low-background Alpha/beta Proportional Counter in Sea Water

    International Nuclear Information System (INIS)

    Pakkong, Pannee; Wongsanit, Sarinya; Tumnoi, Yutthana; Udomsomporn, Suchin

    2011-06-01

    Full text: The determination of gross alpha and beta activity in environmental aqueous samples can be done by using a low-background alpha/beta proportional counter with multiple detector type (Bert hold LB770). The co precipitate sea water samples were considered for optimal regime of counting time, the minimum detectable activity (MDA), mass thickness of samples (mg/cm-2) and figure of merit (FOM). The result showed that the MDA of the measurements were estimated to be 0.07 Bq/l for gross alpha and 0.05 Bq/l for gross beta at counting time of 100 and 200 minute, respectively. The thickness of samples prepared by coprecipitation technique indicated more parochial range when compared to evaporation to dryness method. In addition, the samples were in the suitable range that can be corrected by the previous self-absorption correction factor (F a ) as 0.0003w 2 -0.0414 w+1.692; where F a is the self-absorption correction factor and w is the weight of the final precipitate in milligrams

  7. Gross alpha and beta activities in drinking water from Goias State, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Mingote, Raquel M. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Belo Horizonte, MG (Brazil); Nogueira, Regina A.; Costa, Heliana F. da, E-mail: raquel.mingote@cdtn.br, E-mail: rnogueira@cnen.gov.br, E-mail: heliana@cnen.gov.br [Centro Regional de Ciencias Nucleares do Centro-Oeste (CRCN-CO/CNEN), Abadia de Goias, GO (Brazil). Parque Estadual Telma Ortegal

    2017-07-01

    Detection of gross alpha and beta radioactivity is important for a quick surveying of both natural and anthropogenic radioactivity in water. Furthermore, gross alpha and gross beta parameters are included in Brazilian legislation on quality of drinking water. In this work, a low background liquid scintillation spectrometer was used to simultaneously determine gross alpha and gross beta in samples of the public water supplies in the state of Goias, Brazil, during 2010-2015. Sample preparation involved evaporation to concentrate the sample ten-fold. The results indicate that the water meets the radioactivity standards required by the regulations MS 2914/2011 of the Brazilian Department of Health. Concerning the high level of censored observations, a statistical treatment of data was conducted by using analysis methods of censored data to provide a reference value of the gross alpha and beta radioactivity in drinking water from the state of Goias. The estimated typical activities are very low, 0.030 Bq•L{sup -1} and 0.058 Bq•L{sup -1}, respectively. (author)

  8. Gross alpha and beta activity analyses in urine-a routine laboratory method for internal human radioactivity detection.

    Science.gov (United States)

    Chen, Xiaowen; Zhao, Luqian; Qin, Hongran; Zhao, Meijia; Zhou, Yirui; Yang, Shuqiang; Su, Xu; Xu, Xiaohua

    2014-05-01

    The aim of this work was to develop a method to provide rapid results for humans with internal radioactive contamination. The authors hypothesized that valuable information could be obtained from gas proportional counter techniques by screening urine samples from potentially exposed individuals rapidly. Recommended gross alpha and beta activity screening methods generally employ gas proportional counting techniques. Based on International Standards Organization (ISO) methods, improvements were made in the evaporation process to develop a method to provide rapid results, adequate sensitivity, and minimum sample preparation and operator intervention for humans with internal radioactive contamination. The method described by an American National Standards Institute publication was used to calibrate the gas proportional counter, and urine samples from patients with or without radionuclide treatment were measured to validate the method. By improving the evaporation process, the time required to perform the assay was reduced dramatically. Compared with the reference data, the results of the validation samples were very satisfactory with respect to gross-alpha and gross-beta activities. The gas flow proportional counting method described here has the potential for radioactivity monitoring in the body. This method was easy, efficient, and fast, and its application is of great utility in determining whether a sample should be analyzed by a more complicated method, for example radiochemical and/or γ-spectroscopy. In the future, it may be used commonly in medical examination and nuclear emergency treatment.Health Phys. 106(5):000-000; 2014.

  9. The determination of the national background radioactivity of gross alpha and gross beta in water samples at the PUSPATI site and its neutrons

    International Nuclear Information System (INIS)

    Rahman, M.T.A.

    1983-01-01

    The determination of the natural background radioactivity in water samples has been made at the PUSPATI site and its environs. The study was performed in January 1981 until June 1981. Samples of river, rain and tap water are periodically collected and analyzed in order to determine gross alpha and gross beta activity. In general, the total radioactivity of water is considerably low. The mean concentration of gross alpha in river water and tap water samples are 1.2 +- 0.1 and 0.2 +- 0.1 pCi/ respectively. The level of gross alpha in rain water is however, below the background rate of the detector. The mean concentration of gross beta in river water, tap water and rain water samples are 4.2 +- 0.6, 1.6 +- 0.3, and 1.9 +- 0.3 pCi/ respectively. (author)

  10. The calculation of the detection efficiency in the calibration of gross alpha-beta systems

    International Nuclear Information System (INIS)

    Marian Romeo Calin; Ileana Radulescu; Alexandru Erminiu Druker

    2013-01-01

    This paper presents a method for efficiency calibration of a measuring alpha-beta system PROTEAN ORTEC, MPC-2000-DP, using standard radioactive sources. The system is used to measure gross alpha-beta activity concentrations in environmental samples. The calculated efficiencies of detection were subsequently introduced in the system for two working geometries: measuring geometry-gross alpha-beta ε α g = 31,37 ± 0.25 (%)-the alpha efficiency and ε β g 44.94 ± 0.69 (%)-the beta efficiency, where the spillover factor is X talk g = 25.59 ± 0.50 (%) and measuring geometry up alpha-beta ε α u 36.23 ± 0.29 (%)-the alpha efficiency and ε β u = 48.53 ± 0.74 (%)-the beta efficiency, where the spillover factor is X talk u 31.08 ± 0.60 (%). (author)

  11. Determination of the thoron daughter working level by a one gross alpha-count

    International Nuclear Information System (INIS)

    Bigu, J.; Lau, W.K.

    1983-02-01

    A study has been done on the determination of the thoron daughter Working Level, WL(Tn), by a one gross α-count. The relationship between the gross α-count rate per unit of volume of air sampled and WL(Tn), denoted the F-factor, has been investigated as a function of sampling time, elapsed time from the end of the sampling period, i.e., waiting time, and the thoron daughter disequilibrium ratio [ThC]/[ThB]. It has been found that F depends on both the waiting time and [ThC]/[ThB]. If α-count measurements are made at least 300 min after the end of sampling, F changes by less than 10 percent over the full range of theoretical values of [ThC]/[ThB], i.e., from 0 to 1. The F-factor is independent of [ThC]/[ThB] at approximately 215 min after the end of sampling. This feature can be used to determine WL(Tn) with higher accuracy and at least 1.5 hr earlier than is commonly done using other one gross α-count methods reported in the literature

  12. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Zapata-Garcia, D. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Llaurado, M., E-mail: montse.llaurado@ub.edu [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Rauret, G. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain)

    2012-04-15

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO{sub 3}, produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: Black-Right-Pointing-Pointer We study the effect of alpha and beta energies on PSA optimisation. Black-Right-Pointing-Pointer The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. Black-Right-Pointing-Pointer We study the effect of pH on the simultaneous determination of gross alpha/beta activities. Black-Right-Pointing-Pointer HNO{sub 3} produces a high amount of misclassification at very low pH. Black-Right-Pointing-Pointer The results improve when HCl is used to adjust the sample to low pH.

  13. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    International Nuclear Information System (INIS)

    Zapata-García, D.; Llauradó, M.; Rauret, G.

    2012-01-01

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO 3 , produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: ► We study the effect of alpha and beta energies on PSA optimisation. ► The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. ► We study the effect of pH on the simultaneous determination of gross alpha/beta activities. ► HNO 3 produces a high amount of misclassification at very low pH. ► The results improve when HCl is used to adjust the sample to low pH.

  14. Uranium, thorium, gross alpha and gross beta assessment in fountain waters in towns of the Iron Quadrangle, Brazil

    International Nuclear Information System (INIS)

    Ferreira, Claudia A.; Palmieri, Helena E.L.; Menezes, Maria Angela de B.C.; Chaves, Renata D.A.; Dalmazio, Ilza

    2013-01-01

    The Iron Quadrangle region is known worldwide for its diversity, both ores and rock types, which record a long and important period of Earth's history. For thousands of years erosive processes have exposed ancient rocks, Archean and Proterozoic, in this region. The concentration of uranium, thorium, gross alpha and gross beta activities has been assessed in 34 fountains water samples collected from different towns in the Iron Quadrangle. The results obtained were compared to values established by CONAMA nº 396/2008 and Decree nº 2914/2011 by the Ministry of Health. For Th in water consumption there is no value established in the Brazilian legislation and the concentrations in all samples were lower than 0.01 μg L -1 . For uranium, the values ranged from less than 0.002 to 0.61 μg L -1 , and all results were lower than the value allowed of 15 μg L -1 and 30 μg L -1 established by the legislations above, respectively. The results for the radiation levels of gross alpha and gross beta activity in some fountains waters were slightly above the limits (0.5 Bq L -1 and 1.0 Bq L -1 ) established by CONAMA nº 396/2008 and Decreet nº 2914/2011, respectively. (author)

  15. The Determination of Gross Alpha And Beta Activity of Drinking Water in Turkey

    International Nuclear Information System (INIS)

    Dilaver, A.T.; Cifter, C.; Altay, T.

    2002-01-01

    Man and his environment must be protected from the adverse effects of pesticides, radiation, noise and other forms of pollutions. Radioactive materials occur naturally in the environment (for example uranium, thorium and potassium). Same radioactive compounds arise from human activities (for example from medical or industrial uses of radioactivity). Drinking water should be safe to use and aesthetically pleasing. World Health Organisation (WHO) and Turkish Standards (TSE) have established maximum contaminant levels for gross alpha and gross beta. The purpose of these study is to determine the level of gross alpha and gross beta activities of samples collected from the different Regional Directories of The State Hydraulic Works (DSI)). After that compare the results versus permissible values of World Health Organisation and Turkish Standards. Collected samples from 14 Regional Directories of The State Hydraulic Works (DSI), have completed. All the analyses results suitable for WHO and TSE. We will give all the research our final report after completed the other Regional Directories' s analyses

  16. Uranium, thorium, gross alpha and gross beta assessment in fountain waters in towns of the Iron Quadrangle, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Claudia A.; Palmieri, Helena E.L.; Menezes, Maria Angela de B.C.; Chaves, Renata D.A.; Dalmazio, Ilza, E-mail: cferreiraquimica@yahoo.com.br, E-mail: help@cdtn.br, E-mail: menezes@cdtn.br, E-mail: rda@cdtn.br, E-mail: id@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    The Iron Quadrangle region is known worldwide for its diversity, both ores and rock types, which record a long and important period of Earth's history. For thousands of years erosive processes have exposed ancient rocks, Archean and Proterozoic, in this region. The concentration of uranium, thorium, gross alpha and gross beta activities has been assessed in 34 fountains water samples collected from different towns in the Iron Quadrangle. The results obtained were compared to values established by CONAMA nº 396/2008 and Decree nº 2914/2011 by the Ministry of Health. For Th in water consumption there is no value established in the Brazilian legislation and the concentrations in all samples were lower than 0.01 μg L{sup -1}. For uranium, the values ranged from less than 0.002 to 0.61 μg L{sup -1}, and all results were lower than the value allowed of 15 μg L{sup -1} and 30 μg L{sup -1} established by the legislations above, respectively. The results for the radiation levels of gross alpha and gross beta activity in some fountains waters were slightly above the limits (0.5 Bq L{sup -1} and 1.0 Bq L{sup -1}) established by CONAMA nº 396/2008 and Decreet nº 2914/2011, respectively. (author)

  17. Gross beta activity of the Danube river samples in 2006

    International Nuclear Information System (INIS)

    Tanaskovic, I.; Pantelic, G.; Eremic-Savkovic, M.; Vuletic, V.; Javorina, Lj.; Tanaskovic, I.)

    2007-01-01

    Our paper presents the results of radioactivity control of the Danube samples on Serbian (Bezdan left coast) in 2006. The measurements were carried out by low-phone proportional gas alpha beta counter PIC-WPC-9550. Efficiency for activity was 47%. The results of measurements of gross beta activity (water, sediment, algae and fish) reveal that the values are at the same level as they were before the Paks Nuclear power plant started running. Our results of measurements correlate well with the results of Hungarian part. (author) [sr

  18. Advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1983-01-01

    An improved computer controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high speed matrix printer, and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction, and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha, and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  19. An advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1984-01-01

    An improved computer-controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high-speed matrix printer and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  20. Determination of 90Sr, 129I and gross beta radioactivity concentration in some teas

    International Nuclear Information System (INIS)

    Sultan Sahin; Mahmut Dogru

    2011-01-01

    In this study, 90 Sr (540 keVβ - ), 129 I (150 keVβ - ) and the gross beta radioactivity concentrations were determined for the samples of tea as the most leading consumed hot drink in the markets (processed and packaged for sale) in our country. Furthermore, the obtained data were statistically analyzed. For determination of 129 I (150 keVβ - ), 90 Sr (540 keVβ - ) and gross radioactivity concentrations in tea samples, a sensor system consisting of scintillation detector with BP4 probe sensitive to beta radiation and a radiation meter (ST7) configurable for windows at desired power was used. (author)

  1. High Sensitivity Detection of Xe Isotopes Via Beta-Gamma Coincidence Counting

    International Nuclear Information System (INIS)

    Bowyer, Ted W.; McIntyre, Justin I.; Reeder, Paul L.

    1999-01-01

    Measurement of xenon fission product isotopes is a key element in the global network being established to monitor the Comprehensive Nuclear-Test-Ban Treaty. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which includes a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. The counting geometry is nearly 100% for beta and conversion electrons. The resolution in the pulse height spectrum from the plastic scintillator is sufficient to observe distinct peaks for specific conversion electrons. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. Each of the four xenon isotopes has a distinctive signature in the two-dimensional energy array. The details of the counting system, examples of two-dimensional beta-gamma data, and operational experience with this counting system will be described

  2. Design of New Complex Detector Used for Gross Beta Measuring

    International Nuclear Information System (INIS)

    Zhang Junmin

    2010-01-01

    The level of gross β for radioactive aerosol in the containment of nuclear plants can indicate how serious the radioactive pollution is in the shell, and it can provide evidence which shows whether there is the phenomenon of leak in the boundaries of confined aquifer of the primary coolant circuit equipment.In the process of measuring, the counting of gross β is influenced by γ. In order to avoid the influence of γ, a new method was introduced and a new detector was designed using plastic scintillator as the major detecting component and BGO as the sub-component. Based on distinctive difference of light attenuation time, signal induced in them can be discriminated. γ background in plastic scintillator was subtracted according to the counting of γ in BGO. The functions of absolute detection efficiency were obtained. The simulation for Monte-Carlo method shows that the influence of γ background is decreased about one order of magnitude. (authors)

  3. Methodology for estimation of 32P in bioassay samples by Cerenkov counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Sawant, Pramilla D.; Yadav, R.K.B.; Rao, D.D.

    2016-01-01

    Radioactive phosphorus ( 32 P) as phosphate is used to effectively reduce bone pain in terminal cancer patients. Several hospitals in India carry out this palliative care procedure on a regular basis. Thus, production as well as synthesis of 32 P compounds has increased over the years to meet this requirement. Monitoring of radiation workers handling 32 P compounds is important for further strengthening of radiological protection program at processing facility. 32 P being a pure beta emitter (β max = 1.71 MeV, t 1/2 = 14.3 d), bioassay is the preferred individual monitoring technique. Method standardized at Bioassay Lab, Trombay, includes estimation of 32 P in urine by co-precipitation with ammonium phosphomolybdate (AMP) followed by gross beta counting. In the present study, feasibility of Cerenkov counting for detection of 32 P in bioassay samples was explored and the results obtained were compared with the gross beta counting technique

  4. Gross beta activity and the concentration of sup(90)Sr in the vegetables of Daejeon area

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.Y.; Jun, J.S.; Oh, H.P. (Chungnam National Univ., Taejon (Republic of Korea))

    1984-06-01

    The measurement of gross beta activity and the concentration of sup(90)Sr in the vegetables such as Brassica Campestris, Raphanus Sativus and Lactuca Sativa grown in Daejeon area was carried out during the period of April through August 1983. The observed levels of gross beta activity and the concentration of sup(90)Sr in the levels of the vegetables were, on average, 189.2+-51.8pCi/g-ash (2372+-827pCi/kg-fresh) and 44.4+-11.5sup(90)Sr pCi/g-Ca(2.5+-0.5sup(90) pCi/g-ash or 31.6+-8.6 sup(90)Sr pCi/kg-fresh), respectively, while the mean level of the gross beta activity in roots was 158.6+-19.4pCi/g-ash(2121+-899pCi/kg-fresh). On the basis of the ICRP recommendations, an estimative evaluation was made for the concentration of sup(90)Sr in the vegetables, and it was turned out to be far below the permissible level. An attempt was also made to look for any existing difference in the gross beta, activities of the vegetables grown in vinyl house and in open field, taking seasonal variation of airborne radioactivity into account for normalizing the activity deposited during the course of discrepant farming period.

  5. An intercomparison between gross α counting and gross β counting for grab-sampling determination of airborne radon progeny and thoron progeny

    International Nuclear Information System (INIS)

    Papp, Z.

    2006-01-01

    The instantaneous values of the airborne activity concentrations of radon progeny and thoron progeny have been determined 34 times in a closed and windowless room in a cellar using two independent grab-sampling methods in order to compare the performance of the methods. The activity concentration of radon ( 222 Rn) was also measured and it varied between 200 and 650 Bq m -3 . Two samples of radon and thoron progeny were collected simultaneously from roughly the same air volume by filtering. For the first method, the isotopes were collected on membrane filter and gross α counting was applied over several successive time intervals. This method was a slightly improved version of the methods that are applied generally for this reason for decades. For the second method, the isotopes were collected on glass-fibre filter and gross β counts were registered over several time intervals. This other method was developed a few years ago and the above series of measurements was the first opportunity to make an intercomparison between it and another similar method based on α counting. Individual radon progeny and thoron progeny activity concentrations (for the isotopes 218 Po, 214 Pb, 214 Bi and 212 Pb) were evaluated by both methods. The detailed investigation of the results showed that the systematic deviation of the methods is small but significant and isotope-dependent. The weighted averages of the β/α activity concentration ratios for 218 Po, 214 Pb, 214 Bi, EEDC 222 (Equilibrium-Equivalent Decay-product Concentration of radon progeny) and 212 Pb were 0.99±0.03, 0.90±0.02, 1.03±0.02, 0.96±0.02 and 0.80±0.03, respectively. The source of the systematic deviation is probably the inaccurate knowledge of the counting efficiencies mainly in the case of the α-counting method. A significant random-type difference between the results obtained with the two methods has also been revealed. For example, the β/α ratio for EEDC 222 varied between 0.81±0.01 and 1.22±0

  6. Determining the level of gross alpha and beta radioactivity of water from Marilao river using liquid scintillation counter

    International Nuclear Information System (INIS)

    Cruz, J.; Magtaka, J.; Balisi, R.; Castaneda, Soledad; De Vero, J.

    2009-01-01

    This study aims to determine the level of gross alpha- and beta- radioactivity present in the Marilao River. Liquid Scintillation Counter was used to detect samples radioactivity. Water samples were taken along the different spots of Marilao River. The results showed that the radioactivity are below the Philippine National Standard for Drinking Water (PNSDW) which is 0.1 Bq/L for gross alpha activity and 1.0 Bq/L for gross beta activity set by the Dept. of Health. Hence water samples from Marilao River, is safe in terms of the level of radioactivity levels.(author)

  7. The gross beta activity and the concentration of sup(90)Sr in the vegetables of Daejeon area

    International Nuclear Information System (INIS)

    Lee, J.Y.; Jun, J.S.; Oh, H.P.

    1984-01-01

    The measurement of gross beta activity and the concentration of sup(90)Sr in the vegetables such as Brassica Campestris, Raphanus Sativus and Lactuca Sativa grown in Daejeon area was carried out during the period of April through August 1983. The observed levels of gross beta activity and the concentration of sup(90)Sr in the levels of the vegetables were, on average, 189.2+-51.8pCi/g-ash (2372+-827pCi/kg-fresh) and 44.4+-11.5sup(90)Sr pCi/g-Ca(2.5+-0.5sup(90) pCi/g-ash or 31.6+-8.6 sup(90)Sr pCi/kg-fresh), respectively, while the mean level of the gross beta activity in roots was 158.6+-19.4pCi/g-ash(2121+-899pCi/kg-fresh). On the basis of the ICRP recommendations, an estimative evaluation was made for the concentration of sup(90)Sr in the vegetables, and it was turned out to be far below the permissible level. An attempt was also made to look for any existing difference in the gross beta, activities of the vegetables grown in vinyl house and in open field, taking seasonal variation of airborne radioactivity into account for normalizing the activity deposited during the course of discrepant farming period. (Author)

  8. Design of a Quality Control Program for the Measurement of Gross Alpha and Gross Beta Activities (LMPR-CIEMAT)

    International Nuclear Information System (INIS)

    Alvarez, A.; Yague, L.; Gasco, C.; Navarro, N.; Higueras, E.; Noguerales, C.

    2010-01-01

    In accordance with international standards, general requirements for testing laboratories have to include a quality system for planning, implementing, and assessing the work performed by the organization and for carrying out required quality assurance and quality control. The purpose of internal laboratory quality control is to monitor performance, identify problems, and initiate corrective actions. This report describes the internal quality control to monitor the gross alpha and beta activities determination. Identification of specific performance indicators, the principles that govern their use and statistical means of evaluation are explained. Finally, calculation of alpha and beta specific activities, uncertainties and detection limits are performed. (Author) 10 refs.

  9. Radon Progenies as a Source of Gross Alpha-beta Activities in Drinking Water in Vinaninkarena, Antsirabe-Madagascar

    International Nuclear Information System (INIS)

    Raoelina Andriambololona; Rabesiranana, N.; Rasolonirina, M.; Rakotomanga, H.

    2004-01-01

    The village of Vinaninkarena, Antsirabe, Madagascar is located in a high radioactivity area. With the aim of assessing the health impact of radioactivity pollution, a survey was conducted around an abandoned radium mining. Waters from 24 sampling points, including 5 wells and 13 springs were sampled. The water radioactivity was measured using a portable Triathler LSC, model 425-034 from Hidex Turku. Each sample is counted more than 3 times: less than 2h after sampling, 4h to few days and more than 3 weeks after when 226 Ra attains equilibrium with 222 Rn and its short-lived daughters. Combination of water non miscible, radon extractive LS cocktail and water miscible one is used to reveal contribution of radium, radon and its short lived progenies to the gross alpha-beta activities. Maximum activity values found are : 3.6±0.3 Bq.L -1 for 226 Ra, 554±9 Bq.L -1 for the excess of radon, and 408±8 Bq.L -1 for the excess of radon progenies. Based on these data, a daily consumption of 2 L of these waters by a standard person would produce an annual 226 Ra ingestion well above the annual intake limit for 226 Ra. Moreover, the increasing gross alpha-beta activity resulting from radon progenies raises the issue of health effects. The potential for rapid spring-to-mouth delivery, which is frequent in rural area, may expose the water consumer to the short-lived alpha particle emitters.

  10. A manual low background alpha beta counting system

    Energy Technology Data Exchange (ETDEWEB)

    Levison, S; German, U; Peled, O; Turgeman, S; Vangrovitz, U; Tirosh, D; Piestum, S; Assido, H [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    An Alpha and Beta counting system consisting of a micro controller-based electronic unit and detectors assembly was developed. The radiation detection unit consists of two proportional detectors (a main detector and a cosmic-ray guard detector) which can be easily disassembled for decontamination or repair. The detectors are mounted in a manual operating sample changer shielded by 5 cm of lead. Simplicity of maintenance and functional operation were taken into consideration in the design. The electronic unit supplies the high voltage and enables the operational functions including controls anti alarms. Calculations of net cpm of Alpha and Beta counting are displayed and can be printed. RS-232 communication option enables connection to a computer and operation of more sophisticated programs for calculations and data storage in the future (authors).

  11. A manual low background alpha beta counting system

    International Nuclear Information System (INIS)

    Levison, S.; German, U.; Peled, O.; Turgeman, S.; Vangrovitz, U.; Tirosh, D.; Piestum, S.; Assido, H.

    1996-01-01

    An Alpha and Beta counting system consisting of a micro controller-based electronic unit and detectors assembly was developed. The radiation detection unit consists of two proportional detectors (a main detector and a cosmic-ray guard detector) which can be easily disassembled for decontamination or repair. The detectors are mounted in a manual operating sample changer shielded by 5 cm of lead. Simplicity of maintenance and functional operation were taken into consideration in the design. The electronic unit supplies the high voltage and enables the operational functions including controls anti alarms. Calculations of net cpm of Alpha and Beta counting are displayed and can be printed. RS-232 communication option enables connection to a computer and operation of more sophisticated programs for calculations and data storage in the future (authors)

  12. Radionuclide, scintillation cocktail and chemical/color quench influence on discriminator setting in gross alpha/beta measurements by LSC

    International Nuclear Information System (INIS)

    Stojković, Ivana; Tenjović, Branislava; Nikolov, Jovana; Todorović, Nataša

    2015-01-01

    Gross alpha/beta measurements in drinking waters enable radiochemical composition analysis in environmental studies providing efficient screening method that can indicate whether water contains elevated levels of any radionuclide. Routine gross alpha/beta activity monitoring in drinking waters has been carried out for a few years in laboratory for low-level radioactivity measurements in Novi Sad according to ASTM method, performing measurements on liquid scintillation counter Quantulus 1220 which can simultaneously generate alpha/beta spectra of samples by Pulse Shape Analysis (PSA circuit). In this paper, PSA discriminator impact was investigated to ensure obtaining of accurate and reliable alpha/beta activities. One novelty of presented work is PSA parameter setup with two combinations of radionuclides ( 241 Am, 226 Ra and 90 Sr/ 90 Y) with varying activity concentrations. Performed experiments also make contribution to investigations on the manner in which chemical and color quench affect optimal PSA parameter setting and further on, their altogether influence on gross alpha/beta activity measurements. Nitromethane, 15.8 M nitric acid and water, as well as yellow and yellow-orange dye, were used as quenching agents in order to test PSA/interference factor behavior in the presence of quenchers with different quenching strengths. Variation of PSA setting in quenched samples with two different commercially available cocktails (Ultima Gold LLT and OptiPhase HiSafe 3) was also tested. Lastly, application i.e. assessment of obtained PSA-SQP(E) correlation on the obtained results of activity concentrations of few artesian well water samples and colored spiked samples, based on the measured SQP(E) value of samples, has been demonstrated. - Highlights: • Thorough study on influence of relevant factors on optimal PSA level in gross alpha/beta measurements in waters is presented. • Experiments were performed on liquid scintillation counter Quantulus 1220™ according

  13. Determination of total alpha and beta activities on vegetable samples by LSC

    International Nuclear Information System (INIS)

    Nogueira, Regina Apolinaria; Santos, Eliane Eugenia dos; Bakker, Alexandre Pereira; Vavassori, Giullia

    2011-01-01

    Gross alpha and beta analyses are screening techniques used for environmental radioactivity monitoring. The present study proposes to determine the gross alpha and beta activities in vegetable samples by using LSC - liquid scintillation spectrometry. The procedure was applied to vegetable foods. After ashing vegetable samples in a muffle furnace, 100 mg of ash were added to gel mixture of scintillation cocktails, Water - Instagel - Ultima Gold AB (6:10:4) ml, in polyethylene vial. Am-241 standard solution and a KCl (K-40) solution were used to determine the counting configuration, alpha/beta efficiencies and spillover

  14. Monitoring gross alpha and beta activity in liquids by using ZnS(Ag) scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Stevanato, L.; Cester, D.; Filippi, D.; Lunardon, M.; Mistura, G.; Moretto, S.; Viesti, G. [Department of Physics and Astronomy ' Galileo Galilei' , University of Padova, (Italy); Badocco, D.; Pastore, P.; Romanini, F. [Department of Chemical Sciences, University of Padova, (Italy)

    2015-07-01

    In this work the possibility of monitoring gross alpha and beta activity in liquids using EJ-444 was investigated. Specific tests were carried out to determine the change of the detector properties in water tests. Possible protecting coating is also proposed and tested. Alpha/beta real-time monitoring in liquids is a goal of the EU project TAWARA{sub R}TM. (authors)

  15. Phoswich Detector for Simultaneous Counting of Alpha- and Beta-ray in a Pipe during Decommissioning

    International Nuclear Information System (INIS)

    Seo, B.K.; Kim, G.H.; Woo, Z.H.; Jung, Y.H.; Oh, W.Z.; Lee, K.W.; Han, M.J.

    2006-01-01

    A great quantity of waste has been generated during the decommissioning of nuclear facilities. These wastes are contaminated with various types of alpha, beta, and gamma nuclides. The contamination level of the decommissioning wastes must be surveyed for free release, but it is very difficult to monitor the radioactive contamination level of the pipe inside using conventional counting methods because of the small diameter. In this study a Phoswich detector for simultaneous counting of alpha- and beta-rays in a pipe was developed. The Phoswich detector is convenient for monitoring of alpha and beta contamination using only a single detector, which was composed of thin cylindrical ZnS(Ag) and plastic scintillator. The scintillator for counting an alpha particle has been applied a cylindrical polymer composite sheet, having a double layer structure of an inorganic scintillator ZnS(Ag) layer adhered onto a polymer sub-layer. The sub-layer in an alpha particle counting sheet is made of polysulfone, working as a mechanical and optical support. The ZnS(Ag) layer is formed by coating a ternary mixture of ZnS(Ag), cyano resin as a binder and solvent onto the top of a sub-layer via the screen printing method. The other layer for counting a beta particle used a commercially available plastic scintillator. The plastic scintillator was simulated by using the Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. Characteristics of the detector fabricated were also estimated. As a result, it was confirmed that detector capability was suitable for counting the beta ray. The overall counting results reveal that the developed Phoswich detector is efficient for simultaneous counting of alpha and beta ray in a pipe. (authors)

  16. Measurement of Gross Alpha and Beta Emission Rates from Ceramic Tiles

    International Nuclear Information System (INIS)

    Wudthicharoonpun, Piyasak; Chankow, Nares

    2007-08-01

    Full text: Ceramic tiles normally used to cover floors and walls contain naturally occurring radioactive elements i.e. potassium-40, uranium, thorium and their daughters from raw materials. Thus, radioactivity was dependent upon source of raw materials and the amount used. The objective of this research was to measure gross alpha and beta emission rates to be used as a database for safety assessment and for selection of rooms to measure radioactive radon-222 gas

  17. Gross theory of beta-decay and half-lives of short-lived nuclei

    International Nuclear Information System (INIS)

    Yamada, Masami; Kondo, Norikatsu.

    1976-01-01

    The gross theory of beta-decay has been developed, and this theory offers the means of calculating directly the function of beta-decay intensity, then half-lives, complex beta spectra and so on are estimated from it. This paper presents the more refined theory by introducing the shell effect. The shell effect is considered in the intensity function. The half-lives in the electron decay of In with spin of 9/2 + , the positron decay of Bi, Po, At and Rn, and the decay of odd-odd nuclei were estimated. The introduction of the shell effect shows better agreement between the theory and the experimental data. The inequality relations of intensity functions and half-lives of two adjacent nuclei were obtained. When the spins and parities of two nuclei are same, the inequality relations hold especially good. (Kato, T.)

  18. Evaluation of gross radioactivity in foodstuffs

    International Nuclear Information System (INIS)

    Zorer, Oezlem Selcuk; Oeter, Cigdem

    2015-01-01

    The paper presents the results of radiological investigations of food products sampled in the summer and fall of 2011 and 2012 in different parts of Van, Turkey. Gross radioactivity measurements in food products were evaluated. Food items were divided into eight groups: (1) water, (2) fish, (3) cheese products, (4) fruits, (5) vegetables, (6) herbs, (7) walnut and (8) rock salt. The levels of the gross alpha and gross beta radioactivity in all food samples varied widely ranging from 0.070 to 10.885 Bq/g and from 0.132 to 48.285 Bq/g on dry mass basis, respectively. In one sample, gross alpha and gross beta activity concentrations were found to be relatively high according to the other samples and in all samples, the gross alpha radioactivity was measured lower than the gross beta radioactivity. The gross α and gross β activities were measured by using α/β counter of the multi-detector low background system (PIC MPC-9604).

  19. Evaluation of gross radioactivity in foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Zorer, Oezlem Selcuk; Oeter, Cigdem [Yuzuncu Yil Univ., Van (Turkey). Dept. of Chemistry

    2015-05-15

    The paper presents the results of radiological investigations of food products sampled in the summer and fall of 2011 and 2012 in different parts of Van, Turkey. Gross radioactivity measurements in food products were evaluated. Food items were divided into eight groups: (1) water, (2) fish, (3) cheese products, (4) fruits, (5) vegetables, (6) herbs, (7) walnut and (8) rock salt. The levels of the gross alpha and gross beta radioactivity in all food samples varied widely ranging from 0.070 to 10.885 Bq/g and from 0.132 to 48.285 Bq/g on dry mass basis, respectively. In one sample, gross alpha and gross beta activity concentrations were found to be relatively high according to the other samples and in all samples, the gross alpha radioactivity was measured lower than the gross beta radioactivity. The gross α and gross β activities were measured by using α/β counter of the multi-detector low background system (PIC MPC-9604).

  20. Spreadsheet design and validation for characteristic limits determination in gross alpha and beta measurement

    International Nuclear Information System (INIS)

    Prado, Rodrigo G.P. do; Dalmazio, Ilza

    2013-01-01

    The identification and detection of ionizing radiation are essential requisites of radiation protection. Gross alpha and beta measurements are widely applied as a screening method in radiological characterization, environmental monitoring and industrial applications. As in any other analytical technique, test performance depends on the quality of instrumental measurements and reliability of calculations. Characteristic limits refer to three specific statistics, namely, decision threshold, detection limit and confidence interval, which are fundamental to ensuring the quality of determinations. This work describes a way to calculate characteristic limits for measurements of gross alpha and beta activity applying spreadsheets. The approach used for determination of decision threshold, detection limit and limits of the confidence interval, the mathematical expressions of measurands and uncertainty followed standards guidelines. A succinct overview of this approach and examples are presented and spreadsheets were validated using specific software. Furthermore, these spreadsheets could be used as tool to instruct beginner users of methods for ionizing radiation measurements. (author)

  1. Improvement and automatization of a proportional alpha-beta counting system - FAG

    International Nuclear Information System (INIS)

    German, U.; Levinson, S.; Pelled, O.; Shemesh, Y.; Assido, H.

    1997-01-01

    An alpha and beta counting system - FAG*, for planchette samples is operated at the Health Physics department's laboratory of the NRCN. The original operation mode of the system was based on manual tasks handled by the FHT1 100 electronics. An option for a basic computer keyboard operation was available too. A computer with an appropriate I/O card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. A bar-code laser system for sample number reading was integrated into the Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. authors)

  2. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  3. Low background gas flow beta counting system [Paper No.:M2

    International Nuclear Information System (INIS)

    Abani, M.C.; Anilkumar, S.; Bhende, D.R.; Krishnan, Narayani; Babu, D.A.R.

    1993-01-01

    It is difficult to count beta samples of low specific activity in conventional types of counting systems which have inherently high background. This is specially true in case of environmental samples. A gas flow type beta counter has been developed which have the twin advantage of high efficiency and low background. This system uses a gas flow type main counter and another gas flow type guard counter working on the same principle in anticoincidence mode. Both counters are operated in G.M. region. With this anticoincidence arrangement and lead shielding of 3 inch, the system has the background of the order of 1 cpm and efficiency of 40% for 40 K beta and 14% for 14 C beta. The electronics developed includes a quenching cum coincidence-anticoincidence unit, EHT and a counter timer. This paper describes in detail the development and operational experience with the system. A number of units are already operational at BARC and at Environmental Survey Laboratories set up by Department of Atomic Energy and at various other institutions. (author). 4 refs., 2 figs

  4. Estimation of inhalation doses from airborne releases using gross monitors

    International Nuclear Information System (INIS)

    Goldstein, N.P.

    1978-01-01

    Monitoring programs at most nuclear facilities involve continuous gross measurements supplemented by periodic isotopic analyses of release samples. The isotopic measurements are required to accurately assess the potential dose from the various effluent streams, but in between these measurements, one depends on the gross monitors to provide approximate indications of the dose. The effluent streams release a variety of nuclides, each with its own dose factor. This means that the relationship between the counting rate in a gross monitor and the potential dose of the effluent being monitored will depend on the isotopic composition of this release. If this composition changes, then the dose indicated by the gross monitor (calibrated for the original group of isotopes) may be significantly in error. The problem of indicating inhalation doses from gross monitoring of airborne releases is considered. In order for this type of monitor to accurately indicate dose, regardless of the isotopic makeup of a release, the analysis shows that its response to each isotope should be proportional to the dose factor of that isotope. These ideas are applied to the monitoring of air particulates using gross beta and gross gamma monitors. The study shows that the former more closely satisfies this condition and as a result, satisfactorily indicates the actual dose from reactor effluents, as determined from detailed isotopic data published in the literature. On the other hand, the gross gamma monitor, with its poorer fit to the condition, provided less than satisfactory accuracy in its dose estimates. In addition, a variety of other mathematical response functions were considered but their dose estimation capabilities were not much better than the straight beta response. The study shows that reasonably accurate dose estimates can be made using properly selected gross monitors, but that significant errors can result with improper ones. (author)

  5. Simultaneous and separate, low background counting of beta rays and gamma rays using the phoswich principle

    International Nuclear Information System (INIS)

    Mayhugh, M.R.; Utts, B.K.; Shoffner, B.M.

    1978-01-01

    A phoswich constructed using thin calcium fluoride optically coupled to a thicker sodium iodide crystal and operated with pulse shape analysis equipment can be used as an efficient low background counting assembly. Low background in the beta ray counting channel is achieved by judicious choice of pure materials in the assembly and by operating the analysis equipment so as to reject background events which occur simultaneously in the sodium iodide crystal. Careful survey of construction materials and methods has resulted in reducing beta ray counting background to 0.6 c/min for a 2-inch diameter assembly. The radioactivity of typical building materials will be discussed. A pulse shape analyzer has been constructed which provides separately adjusted time windows and separate output information for the beta ray and gamma ray channels. The dual channel capability combined with the low beta ray background reduces the sample counting time significantly for typical laboratory samples. (author)

  6. Design of a Quality Control Program for the Measurement of Gross Alpha and Gross Beta Activities (LMPR-CIEMAT); Diseno del Control de Calidad de las Medidas de Actividad Alfa-Beta Total (LMPR-CIEMAT)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, A.; Yague, L.; Gasco, C.; Navarro, N.; Higueras, E.; Noguerales, C.

    2010-10-21

    In accordance with international standards, general requirements for testing laboratories have to include a quality system for planning, implementing, and assessing the work performed by the organization and for carrying out required quality assurance and quality control. The purpose of internal laboratory quality control is to monitor performance, identify problems, and initiate corrective actions. This report describes the internal quality control to monitor the gross alpha and beta activities determination. Identification of specific performance indicators, the principles that govern their use and statistical means of evaluation are explained. Finally, calculation of alpha and beta specific activities, uncertainties and detection limits are performed. (Author) 10 refs.

  7. Determination of potassium in feldspars by beta counting using a GM multicounter system

    Energy Technology Data Exchange (ETDEWEB)

    Boetter-Jensen, L; Mejdahl, V

    1985-01-01

    A gas flow multicounter system developed at Risoe National laboratory for low-level beta counting applications was adopted for measuring potassium in feldspars extracted from archaeological and geological materials, in connection with TL dating work. A guard counter reduces the background by using an anticoincidence technique. Calibration was accomplished by measuring KCl and a feldspar standard. A potassium content of 1% yields a net beta count rate (background subtracted) of about 40 c.p.h.; the background is around 15 c.p.h. The precision in repeated measurements is better than 2% and the estimated accuracy is about 3%.

  8. Role of quenching on alpha/beta separation in liquid scintillation counting for several high capacity cocktails

    International Nuclear Information System (INIS)

    Pujol, L.; Sanchez-Cabeza, J.-A.

    1997-01-01

    The optimization of alpha/beta separation in liquid scintillation using pulse shape analysis is convenient for the simultaneous determination of alpha and beta emitters in natural water and other samples. In this work, alpha/beta separation was studied for different scintillant/vial combinations and it was observed that both the optimum pulse shape discrimination level and the total interference value (that is, the summed relative interference between alpha and beta spectra) were dependent on the sample quenching and independent of the scintillant/vial combination. These results provide a simple method for modifying the counting configuration, such as a change in the cocktail, vial or sample characteristics, without the need to perform exhaustive parameter optimizations. Also, it was observed that, for our counting conditions, the combination of Ultima Gold AB scintillation cocktail with Zinsser low diffusion vials presented the lowest total interference, namely 0.94 ± 0.28%, which is insignificant for the counting of environmental samples. (Author)

  9. Refinement of the gross theory of nuclear {beta}-decay, and hindrance of the first-forbidden transition of rank 1

    Energy Technology Data Exchange (ETDEWEB)

    Nakata, Hidehiko [Waseda Univ., Tokyo (Japan). Dept. of Physics; Tachibana, Takahiro; Yamada, Masami

    1997-03-01

    Recently the gross theory of nuclear {beta}-decay was refined for odd-odd nuclei. In this refinement, the effect of the selection rule of {beta}-transitions from the ground states of odd-odd nuclei to those of even-even nuclei was taken into account based on a statistical consideration. The transitions to the first 2{sup +} excited states in even-even nuclei were also taken into account according to the selection rule approximately. In that study, it was found that the transitions between 1{sup -} ground states of the odd-odd nuclei and 0{sup +} ground states of even-even nuclei, belonging to the first-forbidden transitions of rank 1, are strongly hindered. A reduction factor was introduced for the transitions to the ground states of even-even nuclei to take into account this hindrance. It was also found that the strength functions of the Gamow-Teller transitions obtained from the conventional gross theory are underestimated by a factor of about 3. In order to improve this underestimation, the Lorentz-type function was adopted for the one-particle strength function in the model instead of the hyperbolic-secant-type function. In the present study we have newly analyzed the experimental ft-values of odd-A nuclei, and found that the first-forbidden transitions of rank 1 are also considerably hindered between the ground states. Following the above refinement we have calculated the {beta}-ray spectra of some odd-odd short-lived fission products with the use of the refined gross theory. These results are compared not only with the experiments by Rudstam et al. but also with the conventional gross theory. (author)

  10. PC based alpha, beta and gamma counting system

    International Nuclear Information System (INIS)

    Bhattacharya, S.; Gopalakrishnan, K.R.; Bairi, B.R.

    1992-01-01

    In the field of radiation protection and safety a large number of samples have to be assayed for estimation of their radioactivity at various stages in nuclear fuel. A PC based alpha, beta and gamma counting system has been designed for the above application. The system is fully automatic and requires minimum of operator intervention. The main units in the system are detector and pulse processing electronics, sample changer and assembly and IBM PC interface and supporting software. The main function of interface is to control the sample changer which is basically loading and unloading of sample, data acquisition and further processing by software. The pulses from detector are analysed in a pulse shape discriminator. A pulse identified as an alpha, beta or gamma event is converted to digital pulse. These digital pulses are accumulated in the three channels on PC interface each corresponding to alpha, beta and gamma. The sample movements are controlled by interface depending upon sample position. The software has been developed so as to maintain user friendliness and convenience of the operator. Various selection modes for parameters and operation of system provide lot of flexibility in operation of the system. (author). 1 fig

  11. Determination of self absorption correction factor (SAF) for gross alpha measurement in water samples by BIS method

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Baburajan, A.; Ravi, P.M.

    2018-01-01

    The laboratories accredited by AERB undertake the measurement of gross alpha and gross beta in packaged drinking water from manufactures across the country and analyze as per the procedure of Bureau of Indian standards. The accurate measurements of gross alpha in the drinking water sample is a challenge due to the self absorption of alpha particle from varying precipitate (Fe(OH) 3 +BaSO 4 ) thickness and total dissolved solids (TDS). This paper deals with a study on tracer recovery generation and self absorption correction factor (SAF). ESL, Tarapur has participated in an inter-laboratory comparison exercise conducted by IDS, RSSD, BARC as per the recommendation of AERB for the accredited laboratories. The thickness of the precipitate is an important aspect which affected the counting process. The activity was reported after conducting multiple experiments with uranium tracer recovery and precipitate thickness. Later on to make our efforts simplified, an average tracer recovery and Self Absorption correction Factor (SAF) was derived by the present experiment and the same was used for the re-calculation of activity from the count rate reported earlier

  12. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  13. A bar-code reader for an alpha-beta automatic counting system - FAG

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, S; Shemesh, Y; Ankry, N; Assido, H; German, U; Peled, O [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors).

  14. A bar-code reader for an alpha-beta automatic counting system - FAG

    International Nuclear Information System (INIS)

    Levinson, S.; Shemesh, Y.; Ankry, N.; Assido, H.; German, U.; Peled, O.

    1996-01-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors)

  15. Passive non destructive assay of hull waste by gross neutron counting method

    International Nuclear Information System (INIS)

    Andola, Sanjay; Sur, Amit; Rawool, A.M.; Sharma, B.; Kaushik, T.C.; Gupta, S.C.; Basu, Sekhar; Raman Kumar; Agarwal, K.

    2014-01-01

    The special nuclear material accounting (SNMA) is an important and necessary issue now in nuclear waste management. The hull waste generated from dissolution of spent fuel contains small amounts of Uranium and Plutonium and other actinides due to undissolved trapped material inside zircoalloy tubes. We report here on the development of a Passive Hull monitoring system using gross neutron counting technique and its implementation with semiautomatic instrumentation. The overall sensitivity of the 3 He detector banks placed at 75 cm from the centre of loaded hull cask comes out to 5.2 x 10 -3 counts per neutron (c/n) while with standard Pu-Be source placed in same position it comes out to be 3.1 x 10 3 c/n. The difference in the efficiency is mainly because of the differences in the geometry and size of hull cask as well as difference in the energy spectrum of hull waste and Pu-Be source. This is accounted through Monte Carlo computations. The Pu mass in solid waste comes out as expected and varies with the surface dose rate of drum in almost a proportional manner. Being simple and less time consuming, this setup has been installed for routine assay of solid Hull waste at NRB, Tarapur

  16. Determination of Potassium in Feldspars by Beta Counting Using a GM Multicounter System

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Mejdahl, V.

    1985-01-01

    A gas flow multicounter system developed at Riso National Laboratory for low-level beta counting applications was adopted for measuring potassium in feldspars extracted from archaeological and geological materials, in connection with TL dating work. A guard counter reduces the background by using...

  17. Development of methodology for detection of long lived alpha emitters in air based on simultaneous alpha and beta activity measurement

    International Nuclear Information System (INIS)

    Kaushik, Vivek; Rath, D.P.; Vinayagami, Bhakti; Ashokkumar, P.; Umashankar, C.; Gopalakrishnan, R.K.; Kulkarni, M.S.

    2018-01-01

    Interference of the radon and thoron progeny co-deposited on the filtration media is the long-standing problem related to prompt analyses in continuous air sampling or monitoring of any potential suspect radionuclides. The solutions to this problem have been quite diverse, and included, for example, simple gross-alpha counting, the use of beta-to-alpha ratios, and the use of alpha spectrum analyses. The techniques based on beta to alpha disintegration ratios make use of the naturally occurring alpha to beta disintegration ratios and departures therefrom. This ratio is found empirically to be relatively constant. With the help of the solution of differential equation, which govern the deposition of radionuclide on filter paper, one can easily estimate theoretically the behavior of the radon progeny alpha to beta disintegration (or count) rate ratio

  18. Investigation and study of radioactive dusts in high altitude air. Consideration on the long-term trends of gross beta activity

    International Nuclear Information System (INIS)

    Ogino, Kumiko; Sato, Mihoko

    2005-01-01

    The data for radioactivities of airborne dust that have been measured by JDA since 1961 was stored in database. Generally, the gross beta activity that have been obtained in the past was analyzed, using the data base. The behavior of fallout in environment and the effect on Japanese sky were considered. (author)

  19. Particle count monitoring of reverse osmosis water treatment for removal of low-level radionuclides

    International Nuclear Information System (INIS)

    Moritz, E.J.; Hoffman, C.R.; Hergert, T.R.

    1995-01-01

    Laser diode particle counting technology and analytical measurements were used to evaluate a pilot-scale reverse osmosis (RO) water treatment system for removal of particulate matter and sub-picocurie low-level radionuclides. Stormwater mixed with Waste Water Treatment Plant (WWTP) effluent from the Rocky Flats Environmental Technology Site (RFETS), formerly a Department of Energy (DOE) nuclear weapons production facility, were treated. No chemical pretreatment of the water was utilized during this study. The treatment system was staged as follows: multimedia filtration, granular activated carbon adsorption, hollow tube ultrafiltration, and reverse osmosis membrane filtration. Various recovery rates and two RO membrane models were tested. Analytical measurements included total suspended solids (TSS), total dissolved solids (TDS), gross alpha (α) and gross beta (β) activity, uranium isotopes 233/234 U and 238 U, plutonium 239/240 Pu, and americium 241 Am. Particle measurement between 1--150 microns (μ) included differential particle counts (DPC), and total particle counts (TPC) before and after treatment at various sampling points throughout the test. Performance testing showed this treatment system produced a high quality effluent in clarity and purity. Compared to raw water levels, TSS was reduced to below detection of 5 milligrams per liter (mg/L) and TDS reduced by 98%. Gross α was essentially removed 100%, and gross β was reduced an average of 94%. Uranium activity was reduced by 99%. TPC between 1-150μ were reduced by an average 99.8% to less than 1,000 counts per milliliter (mL), similar in purity to a good drinking water treatment plant. Raw water levels of 239/240 Pu and 241 Am were below reliable quantitation limits and thus no removal efficiencies could be determined for these species

  20. Beta-gamma counting system for Xe fission products

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; Perkins, R.W.

    1998-01-01

    A beta-gamma coincidence counting system has been developed for automated analysis of Xe gas samples separated from air. The Xe gas samples are contained in a cylindrical plastic scintillator cell located between two NaI(Tl) scintillation detectors. The X-ray and gamma spectra gated by coincident events in the plastic scintillator cell are recorded for each NaI(Tl) crystal. The characteristic signatures of the 131m Xe, 133g Xe, 133m Xe, and 135g Xe isotopes of interest for nuclear test-ban verification as well as the procedures and results of absolute efficiency measurements are described. A NaI(Tl) crystal with provision for 4 sample cells has been implemented for the system to be deployed in the field. Examples of data on ambient air samples in New York City obtained with the field prototype are presented. (author)

  1. Evaluation of polymer-coated CsI:Tl as an alpha/beta pulse shape discriminating flow-cell

    International Nuclear Information System (INIS)

    Branton, S.D.; Fjeld, R.A.; DeVol, T.A.

    1996-01-01

    A pulse shape discriminating flow-cell radiation detection system constructed with polymer coated CsI:Tl was evaluated for simultaneous gross alpha/gross beta quantification. The CsI:TI scintillator was crushed and sieved to 63-90 μm particle size and microencapsulated with Parylene C to reduce its rate of dissolution. Averaged over the first hour of use, the pulse shape discrimination figure-of-merit was 1.4 and the detection efficiencies were 64.9 ± 5.7 %, 52.5 ± 4.5 % and 4.5 ± 0.2 % for 233 U, 90 Sr/ 90 Y and 14 C , respectively. The typical background count rate in the alpha and beta pulse shape window was 0.17 and 0.004 cps, respectively. The resultant minimum detectable activity for a 30 second count time was calculated to be 0.19 ± 0.01 Bq, 0.9 ± 0.1 Bq and 11.4 ± 0.6 Bq for 233 U, 90 Sr/ 90 Y and 14 C, respectively. Although the 3 μm thick microencapsulation reduced CsI:Tl dissolution, the detection efficiency declined by a factor of two after 4.8 hours while the pulse shape resolution degraded slightly

  2. Evaluation of induced radioactivity in 10 MeV-Electron irradiated spices, (2); [beta]-ray counting

    Energy Technology Data Exchange (ETDEWEB)

    Katayama, Tadashi; Furuta, Masakazu; Shibata, Setsuko; Matsunami, Tadao; Ito, Norio; Mizohata, Akira; Toratani, Hirokazu (Osaka Prefectural Univ., Sakai (Japan). Research Inst. for Advanced Science and Technology); Takeda, Atsuhiko

    1994-02-01

    In order to check radioactivity of beta-emmitters produced by ([gamma], n) reactions which could occur at energies up to 10 MeV, black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeV electron from a linear accelerator to a dose of 100 kGy. Beta-rays were counted using a 2[pi] gas flow counter and a liquid scintillation counter. Any induced radioactivity could not be detected in irradiated samples. When inorganic compounds containing the nuclides in the list were artificially added in the samples and were irradiated, the [beta]-activities were detected. From the amount of observed radioactivities of [beta]-emmitters produced in the compounds as photonuclear products, it is concluded that the induced radioactivity in natural samples by 10 MeV-electron irradiation were far smaller than natural radioactivity from [sup 40]K contained in the samples and, hence, its biological effects should be negligible. (author).

  3. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  4. Identification and quantitative grade estimation of Uranium mineralization based on gross-count gamma ray log at Lemajung sector West Kalimantan

    International Nuclear Information System (INIS)

    Adi Gunawan Muhammad

    2014-01-01

    Lemajung sector, is one of uranium potential sector in Kalan Area, West Kalimantan. Uranium mineralization is found in metasiltstone and schistose metapelite rock with general direction of mineralization east - west tilted ± 70° to the north parallel with schistocity pattern (S1). Drilling evaluation has been implemented in 2013 in Lemajung sector at R-05 (LEML-(S1). Drilling evaluation has been implemented in 2013 in Lemajung sector at R-05 (LEML-gamma ray. The purpose of this activity is to determine uranium mineralization grade with quantitatively methode in the rocks and also determine the geological conditions in sorounding of drilling area. The methodology involves determining the value of k-factor, geological mapping for the sorounding of drill hole, determination of the thickness and grade estimation of uranium mineralization with gross-count gamma ray. Quantitatively from grade estimation of uranium using gross-count gamma ray log can be known that the highest % eU_3O_8 in the hole R-05 (LEML-40) reaches 0.7493≈6354 ppm eU found at depth interval from 30.1 to 34.96 m. Uranium mineralization is present as fracture filling (vein) or tectonic breccia matrix filling in metasiltstone with thickness from 0.10 to 2.40 m associated with sulphide (pyrite) and characterized by high ratio of U/Th. (author)

  5. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system

    International Nuclear Information System (INIS)

    Carlos, J. E. de; Granados, C. E.

    1972-01-01

    In 4π β-γ coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between theβ--and γ-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs

  6. Screening procedures for alpha, beta and gamma emitting radionuclides in urine

    International Nuclear Information System (INIS)

    Kramer, G.H.; Gardner, S.E.; Johnson, J.R.

    1983-08-01

    The gross actinide and beta screening methods currently used by the Bioassay Laboratory at Chalk River Nuclear Laboratories have been documented and tested. The gross gamma method has also been documented. The gross actinide method was tested with Th-nat, Pu-239, Np-237, Am-241 and Cm-244 and the average percent recoveries were 90, 99, 45, 72 and 78, respectively. The gross beta method was tested with Sr-90/Y-90, Ce-144/Pr-144, Pm-147 and Ba-133 and the average percent recoveries were 78, 100, 46 and 46, respectively. Detection limits for the gross actinide (alpha) method are found to be about 0.4 mBq and about 39 mBq for the gross beta method

  7. Analysis of fresh fallout from Chinese tests by beta counting technique

    International Nuclear Information System (INIS)

    Mishra, U.C.; Lalit, B.Y.; Shukla, V.K.; Ramachandran, T.V.

    1979-01-01

    The paper describes beta counting techniques used in the analysis of fresh radioactive fallout samples from nuclear weapon tests. Fresh fallout samples have been collected by swiping the exposed portion of the engine covers of commercial aircrafts arriving at Bombay from New York after Chinese tests on September 26, 1976 and September 17, 1977. Activities of short-lived radionuclides such as Ag 111, Sr 89, Mo 99, U 237 and Np 239 were determined using these techniques. The results obtained from this analysis is discussed in brief in relation to the kind of fissile material, the extent of thermonuclear reaction in the weapon and the mode of detonation. (orig.) [de

  8. Determination of radon daughter activities of different aerosol fractions by gross-α and gross-β measurements

    International Nuclear Information System (INIS)

    Katona, T.; Kanyar, B.; Jobbagy, V.; Kavasi, N.; Molnar, A.; Imre, K.

    2004-01-01

    The aim was to determine the radioactivities of the radon progenies ( 218 Po, 214 Pb, 214 Bi and 214 Po) attached to the carrier aerosol particles with respect to the size distribution in order to improve the assessment of the inhalation dose. We derived the radionuclide-specific activity concentrations from gross alpha and gross beta measurements provided during 2 hours after sampling and model calculations including parameter estimation. For the aerosol sampling we used an electrical low pressure impactor, which is able to collect aerosol particles in 12 different diameter ranges. In our test investigations the aerosol particles were collected from a closed chamber in a common laboratory building. The chamber contained a relatively high radon concentration (60-90 kBq/m 3 ) in equilibrium with the short lived daughters generated previously without any additional aerosol sources. For the nuclear measurements of the aerosol samples ZnS/plastic sandwich detectors have been used. The time series data of gross alpha and gross beta activities were fitted simultaneously and the initial activities of the daughters were estimated. According to the results from two different fractions (0.06 and 0.7 μm) just followed the end of sampling they contain a higher 218 Po activity than the 214 Pb and 214 Bi ones. The preliminary assessments for the special air conditions show that the 214 Pb-to- 218 Po activity ratios are higher for the small aerosol particles than for the larger ones. The estimated errors of the initial activities were near to 50% in a large part of cases. (author)

  9. Assessment of radiological risk parameters associated with some selected rivers around oil mineral producing sites in Abia State, Nigeria due to gross alpha and beta radiations

    International Nuclear Information System (INIS)

    Enyinna, Paschal Ikenna; Uzochukwu, Francis C.

    2016-01-01

    The study of gross alpha and beta radiation in environmental components and water bodies in particular is very crucial to the environmental, radiation and medical Physicist as this helps to promote good water quality and environmental hygiene. This research work understudied the radiological risk parameters due to gross alpha and beta radiations associated with three selected rivers around crude oil production sites in Abia State, Nigeria. Gross alpha and beta activities were computed for the three rivers based on analytical measurements carried out using a well-calibrated IN-20 model gas-flow proportional counter. Radiological risk parameters were computed from the activity concentrations which included; annual effective dose equivalent of radiation from ingested water (AEDE), annual gonadal dose equivalent (AGDE), and excess lifetime cancer risk (ELCR). The mean of the total AEDE due to the sum of alpha and beta radiations for the three rivers are 0.868 ± 0.221 mSv/y, 1.008 ± 0.156 mSv/y, and 0.917 ± 0.214 mSv/y; and are above the World Health Organization (WHO) permissible limit of 0.1 mSv/y. The mean of the total AGDE are 4.048 ± 1.063 mSv/y, 4.756 ± 0.739 mSv/y, and 4.295 ± 1.026 mSv/y; and are above the world average limit of 0.3 mSv/y. The mean of the total ELCR are (3.038 ± 0.774) X 10"-"3, (3.529 ± 0.547) X 10"-"3, and (3.210 ± 0.748) X 10"-"3; and are above the world average limit of 0.29 X 10"-"3. Most values of ELCR computed in this work are >6.0 X 10"-"4 estimated to be the risk of fatal and weighted nonfatal health conditions over a lifetime (70 years) derived from the radiation dose of 0.1 mSv/y (WHO permissible limit for drinking water). Drinking water from these surveyed sources could impact negatively on the end users. (author)

  10. Radon Daughters Background Reduction in Alpha Particles Counting System

    International Nuclear Information System (INIS)

    Dadon, S. S.; Pelled, O.; Orion, I.

    2014-01-01

    The ABPC method is using a serially occurring events of the beta decay of the 214Bi fallow by alpha decay of the 214Po that take place almost simultaneously to detect the Pseudo Coincidence Event (PCE) from the RDP, and to subtract them from the gross alpha counts. 267 This work showed that it is possible to improve the efficiency of RDP background reduction, including subtracting the 218Po contribution by using the ABPC method based on a single solid state silicon PIPS detector. False counts percentage obtained at the output of the PCE circuit were smaller than 0.1%. The results show that the PCE circuit was not influenced by non RDP alpha emitters. The PCE system did not reduce the non PCE of the 218Po. After 20 minutes the 218Po was strongly decayed, and its contribution became negligible. In order to overcome this disadvantage, a mathematical matching calculations for the 214Po and the 218Po decay equations were employed, and a constant ratio of the APo214(0) / APo218(0) was obtained. This ratio can be used to estimate the count rate of the 218Po at the first 20 minutes, and to subtract it from the total count rate in order to obtain correct RDP reduction

  11. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system; Informe preliminar del sistema Samar sistema automatico de medidas absolutas de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Carlos, J E. de; Granados, C E

    1972-07-01

    In 4{pi} {beta}-{gamma} coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between the{beta}--and {gamma}-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs.

  12. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system; Informe preliminar del sistema Samar sistema automatico de medidas absolutas de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Carlos, J. E. de; Granados, C. E.

    1972-07-01

    In 4{pi} {beta}-{gamma} coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between the{beta}--and {gamma}-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs.

  13. Technical Basis for the Use of Alpha Absorption Corrections on RCF Gross Alpha Data

    International Nuclear Information System (INIS)

    Ceffalo, G.M.

    1999-01-01

    This document provides the supporting data and rationale for making absorption corrections to gross alpha data to correct alpha data for loss due to absorption in the sample matrix. For some time there has been concern that the gross alpha data produced by the Environmental Restoration Contractor Radiological Counting Facility, particularly gross alpha analysis on soils, has been biased toward low results, as no correction for self-absorption was applied to the counting data. The process was investigated, and a new methodology for alpha self-absorption has been developed

  14. Gamma-spectrometric and total alpha-beta counting methods for radioactivity analysis of deuterium depleted water

    International Nuclear Information System (INIS)

    Ferdes, Ov. S.; Mladin, C.; Vladu, Mihaela; Bulubasa, G.; Bidica, N.

    2008-01-01

    According to national regulations, as well as to the EU directive on the quality of drinking water, the radionuclide concentrations represent some of the drinking water quality parameters. Among the most important radioactivity content parameters are: the total alpha and total beta concentration (Bq/l); K-40 content, and the gamma-nuclides volume activities. The paper presents the measuring methods for low-level total alpha and/or beta counting of volume samples, as well as the high-resolution gamma-ray spectrometric method used to measure the volume activity of nuclides in drinking water. These methods are applied to monitor the radioactivity content and quality of the QLARIVIA brand of Deuterium depleted water (DDW). There are discussed the performances of these applied methods as well as some preliminary results. (authors)

  15. Determination of beta and gamma radioactivity on the coal

    International Nuclear Information System (INIS)

    Suhardi; Mulyono; Sutanto WW; Rosidi

    2013-01-01

    Radioactivity in coal, botton ash and fly ash. This determination was carried out to know each the radioactivity of β gross, γ gross on the coal, botton ash and fly ash, which accommodation of environment data the present in PLTU Paiton Probolinggo. Samples taken preparation and analysis based on the procedures of environmental radioactivity analysis. The radioactivity on the PLTU Paiton Probolinggo detected by beta gross Spectrometer with Geiger Muller (GM) and gamma Spectrometer with Ge(Li) detector. The result indicates that radioactivity concentration of beta and gamma gross are (95,57-308,26) Bq/kg and (1,374 - 31,677) Bq/kg respectively. (author)

  16. Improvement of gross theory of beta-decay for application to nuclear data

    Science.gov (United States)

    Koura, Hiroyuki; Yoshida, Tadashi; Tachibana, Takahiro; Chiba, Satoshi

    2017-09-01

    A theoretical study of β decay and delayed neutron has been carried out with a global β-decay model, the gross theory. The gross theory is based on a consideration of the sum rule of the β-strength function, and gives reasonable results of β-decay rates and delayed neutron in the entire nuclear mass region. In a fissioning nucleus, neutrons are produced by β decay of neutron-rich fission fragments from actinides known as delayed neutrons. The average number of delayed neutrons is estimated based on the sum of the β-delayed neutron-emission probabilities multiplied by the cumulative fission yield for each nucleus. Such a behavior is important to manipulate nuclear reactors, and when we adopt some new high-burn-up reactors, properties of minor actinides will play an important roll in the system, but these data have not been sufficient. We re-analyze and improve the gross theory. For example, we considered the parity of neutrons and protons at the Fermi surface, and treat a suppression for the allowed transitions in the framework of the gross theory. By using the improved gross theory, underestimated half-lives in the neutron-rich indium isotopes and neighboring region increase, and consequently follow experimental trend. The ability of reproduction (and also prediction) of the β-decay rates, delayed-neutron emission probabilities is discussed. With this work, we have described the development of a programming code of the gross theory of β-decay including the improved parts. After preparation finished, this code can be released for the nuclear data community.

  17. Selection of the ''best'' model for converting beta backscatter count readings into thickness measurements

    International Nuclear Information System (INIS)

    Smiriga, N.G.

    1976-01-01

    This report compares two models for converting beta backscatter count readings into thickness measurements. The necessary formulas to be used in an unweighted and weighted regression analysis are listed. The question of whether one should perform a regression analysis using the five available standard thicknesses or whether one should, in addition to these standard thicknesses, use zero as a standard thickness is decided. A weighted regression analysis is compared with an unweighted one for each model. The ''best'' model is selected, and the conclusions of the analysis are presented

  18. "Lost milk?": Counting the economic value of breast milk in gross domestic product.

    Science.gov (United States)

    Smith, J P

    2013-11-01

    The contribution of breastfeeding and mothers milk to the economy is invisible in economic statistics. This article demonstrates how the economic value of human milk production can be included in economic statistics such as gross domestic product (GDP) and provides estimates for Australia, the United States, and Norway. The contribution of human milk and lactation to GDP in these countries is estimated using United Nations (System of National Accounting) guidelines and conventional economic valuation approaches to measuring production in GDP. In Australia, current human milk production levels exceed $3 billion annually. The United States has the potential to produce human milk worth more than US$110 billion a year, but currently nearly two thirds of this value is lost due to premature weaning. In Norway, production valued at US$907 million annually is 60% of its potential value. The potential loss of economic value from not protecting women's lactation and milk production from competing market pressures is large. Failure to account for mothers' milk production in GDP and other economic data has important consequences for public policy. The invisibility of human milk reduces the perceived importance of programs and regulations that protect and support women to breastfeed. The value of human milk can be measured using accepted international guidelines for calculating national income and production. It is quantitatively nontrivial and should be counted in GDP.

  19. Few remarks on the absolute counting of {beta} emitters using 4 {pi} counter; Quelques remarques sur la mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B; Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This study looks to determinate the optimum experimental conditions which allow the best accuracy possible for the absolute counting of {beta} emitters when using a 4 {pi} counter. The study has been done with a 4 {pi} counter using source supports of 30 {mu}m thickness. The associated electronic circuit includes: high-voltage, a 1000 scale and a dead time preafier of 4x10{sup -4} {mu}s. In addition, a coincidence preamplifier - with 1 {mu}s resolution time - was added which permits to count the coincidence between the measuring channels. It compares the measurement accuracy and the absorption correction needed for different source supports including polymers thin films with and without metal coating. (M.P.)

  20. Beta activity measurements in high, variable gamma backgrounds

    International Nuclear Information System (INIS)

    Stanga, D.; Sandu, E.; Craciun, L.

    1997-01-01

    In many cases beta activity measurements must be performed in high and variable gamma backgrounds. In such instances it is necessary to use well-shielded detectors but this technique is limited to laboratory equipment and frequently insufficient. In order to perform in a simple manner beta activity measurements in high and variable backgrounds a software-aided counting technique have been developed and a counting system have been constructed. This technique combines the different counting techniques with traditional method of successive measurement of the sample and background. The counting system is based on a programmable multi-scaler which is endowed with appropriate software and allow all operations to be performed via keyboard in an interactive fashion. Two large - area proportional detectors were selected in order to have the same background and the same gamma response within 5%. A program has been developed for the counting data analysis and beta activity computing. The software-aided counting technique has been implemented for beta activity measurement in high and variable backgrounds. (authors)

  1. Study of the radioactivity of drinking water in the city of Antsirabe using the method of liquid scintillation counting

    International Nuclear Information System (INIS)

    RAKOTOMANGA, H.

    2003-01-01

    The objective of this work is to determine the radioactivity by liquid scintillation counting (LSC) and to study the distribution of radionuclides in drinking water from the Antsirabe region. Optiphase Hisafe 3TM is used to measure gross alpha-beta radioactivity. Radium, radon and the excess of short half-life radionuclides are obtained from MaxilightTM cocktail. Results of measurement of drinking water samples show that : gross alpha-beta activities are between (120±27) Bq.l -1 and (426±47) Bq.l -1 , the radium activities are from (14±2)Bq.l -1 to (78±5) Bq.l -1 , radon activities are from (0.6±0.2)Bq.l -1 to (60±6) Bq.l -1 , short half-life radionuclides activities are between 25±8 Bq.l -1 and 270±27 Bq.l -1 .Annual dose exposure from ingestion of radium-226 is between (2.09 ± 0.32)mSv and (11.03 ± 0.73)mSv. These values are close to the Malagasy standard (5 mSv). The results show that drinking waters from the Antsirabe region contain natural radionuclides. Dose exposure increases if the water is directly ingested after collection. [fr

  2. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter); Determinacao de atividades alfa e beta total em agua para consumo humano por LSC (Contador de Cintilacao Liquida))

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  3. Beta/alpha continuous air monitor

    Science.gov (United States)

    Becker, G.K.; Martz, D.E.

    1988-06-27

    A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinquishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts. 7 figs.

  4. Assessment of natural radioactivity and heavy metals in water and soil around seismically active area

    International Nuclear Information System (INIS)

    Oktay Baykara; Mahmut Dogru; Firat University, Elazig

    2010-01-01

    The natural radioactivity concentration and some heavy metals in various water and soil samples collected from seismically active area have been determined. Gross-alpha and beta concentrations of different 33 water samples and some heavy metal (Fe, Pb, Cu, K, Mn, Cr and Zn) concentration in 72 soil samples collected from two major fault systems (North and East Anatolian Active Fault Systems) in Turkey have been studied. This survey regarding gross-alpha and beta radioactivity and some heavy metals concentrations was carried out by means of Krieger method using a gross-alpha and beta-counting system and atomic absorption spectrometry (AAS), respectively. Also, gross annual effective dose from the average gross-alpha activity in waters were calculated. (author)

  5. The Schroedinger functional for Gross-Neveu models

    International Nuclear Information System (INIS)

    Leder, B.

    2007-01-01

    Gross-Neveu type models with a finite number of fermion flavours are studied on a two-dimensional Euclidean space-time lattice. The models are asymptotically free and are invariant under a chiral symmetry. These similarities to QCD make them perfect benchmark systems for fermion actions used in large scale lattice QCD computations. The Schroedinger functional for the Gross-Neveu models is defined for both, Wilson and Ginsparg-Wilson fermions, and shown to be renormalisable in 1-loop lattice perturbation theory. In two dimensions four fermion interactions of the Gross-Neveu models have dimensionless coupling constants. The symmetry properties of the four fermion interaction terms and the relations among them are discussed. For Wilson fermions chiral symmetry is explicitly broken and additional terms must be included in the action. Chiral symmetry is restored up to cut-off effects by tuning the bare mass and one of the couplings. The critical mass and the symmetry restoring coupling are computed to second order in lattice perturbation theory. This result is used in the 1-loop computation of the renormalised couplings and the associated beta-functions. The renormalised couplings are defined in terms of suitable boundary-to-boundary correlation functions. In the computation the known first order coefficients of the beta-functions are reproduced. One of the couplings is found to have a vanishing betafunction. The calculation is repeated for the recently proposed Schroedinger functional with exact chiral symmetry, i.e. Ginsparg-Wilson fermions. The renormalisation pattern is found to be the same as in the Wilson case. Using the regularisation dependent finite part of the renormalised couplings, the ratio of the Lambda-parameters is computed. (orig.)

  6. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  7. Alpha/beta separation in liquid scintillation gel samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1994-01-01

    The pulse shape analysis commonly used in liquid scintillation alpha/beta separations is satisfactory for moderate quench levels. However, for gel samples, the alpha particle counting efficiency is never greater than 10%, and an optimum separation of the alpha component cannot be achieved when beta to alpha counting rate ratios are greater than 100. In such cases, it is better to use a spectrum analysis method for alpha/beta separation. ((orig.))

  8. Operating program for an automatic alpha-beta counting system-FAG

    Energy Technology Data Exchange (ETDEWEB)

    German, U; Levinson, L; Shemesh, Y; Peled, O; Weistein, M [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    An alpha and beta counting system - FAG, for planchette samples is operated at the Health Physics department`s laboratory of the NRCN. The system consists of a proportional detector of 8`` diameter operated in coincidence with a guard detector, an automatic sample changer (FAG-FHT770E) and electronics (FAG- FHT1100 digital counter and controller). The original operation mode of the system was based on manual tasks handled by the FHT1100 electronics. Pin option for a basic computer keyboard operation was available too. A computer with appropriate 110 card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. The program which was developed enables computer control of all components of the system, based on bi-directional communication. The computer software controls the FHT1100 electronics using the R5232 protocol and the sample changer by an additional 110 card Contec Inodel PIO-48W(PC). The computer controls the whole operation of the system: change of samples, high voltage change, start, stop etc. It handles in the appropriate order the different commands and operates the electronic and mechanic components accordingly (authors).

  9. Operating program for an automatic alpha-beta counting system-FAG

    International Nuclear Information System (INIS)

    German, U.; Levinson, L.; Shemesh, Y.; Peled, O.; Weistein, M.

    1996-01-01

    An alpha and beta counting system - FAG, for planchette samples is operated at the Health Physics department's laboratory of the NRCN. The system consists of a proportional detector of 8'' diameter operated in coincidence with a guard detector, an automatic sample changer (FAG-FHT770E) and electronics (FAG- FHT1100 digital counter and controller). The original operation mode of the system was based on manual tasks handled by the FHT1100 electronics. Pin option for a basic computer keyboard operation was available too. A computer with appropriate 110 card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. The program which was developed enables computer control of all components of the system, based on bi-directional communication. The computer software controls the FHT1100 electronics using the R5232 protocol and the sample changer by an additional 110 card Contec Inodel PIO-48W(PC). The computer controls the whole operation of the system: change of samples, high voltage change, start, stop etc. It handles in the appropriate order the different commands and operates the electronic and mechanic components accordingly (authors)

  10. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter)

    International Nuclear Information System (INIS)

    2013-01-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  11. Water quality - Measurement of gross alpha activity in non-saline water - Thick source method. 2. ed.

    International Nuclear Information System (INIS)

    2007-01-01

    This International Standard specifies a method for the determination of gross alpha activity in non-saline waters for alpha-emitting radionuclides which are not volatile at 350 degree Centigrade. It is possible to determine supported volatile radionuclides measured to an extent determined by half-life, matrix retention (of the volatile species) and the duration of measurement (counting time). The method is applicable to raw and potable waters. The range of application depends on the amount of suspended matter in the water and on the performance characteristics (background count rate and counting efficiency) of the counter. Gross alpha radioactivity is determined by using proportional counting or solid scintillation counting on water residue deposited on a planchet. Due to the strong absorption of the residue deposit, it is considered that the alpha emission from the surface is proportional to the alpha activity of the deposit. Gross alpha determination is not an absolute determination of the sample alpha radioactive content, but a relative determination referring to a specific alpha emitter which constitutes the standard calibration source. This type of determination is also known as alpha index. The sample is acidified to stabilize it, evaporated almost to dryness, converted to the sulfate form and then ignited at 350 degree Centigrade. A portion of the residue is transferred to a planchet and the alpha activity measured by counting in an alpha-particle detector or counting system previously calibrated against an alpha-emitting standard and the alpha activity concentration calculated. The paper provides information about scope, normative references, symbols, definitions and units, principle, reagents and equipment, procedure, contamination check, expression of results and test report

  12. Total lymphocyte count and subpopulation lymphocyte counts in relation to dietary intake and nutritional status of peritoneal dialysis patients.

    Science.gov (United States)

    Grzegorzewska, Alicja E; Leander, Magdalena

    2005-01-01

    Dietary deficiency causes abnormalities in circulating lymphocyte counts. For the present paper, we evaluated correlations between total and subpopulation lymphocyte counts (TLC, SLCs) and parameters of nutrition in peritoneal dialysis (PD) patients. Studies were carried out in 55 patients treated with PD for 22.2 +/- 11.4 months. Parameters of nutritional status included total body mass, lean body mass (LBM), body mass index (BMI), and laboratory indices [total protein, albumin, iron, ferritin, and total iron binding capacity (TIBC)]. The SLCs were evaluated using flow cytometry. Positive correlations were seen between TLC and dietary intake of niacin; TLC and CD8 and CD16+56 counts and energy delivered from protein; CD4 count and beta-carotene and monounsaturated fatty acids 17:1 intake; and CD19 count and potassium, copper, vitamin A, and beta-carotene intake. Anorexia negatively influenced CD19 count. Serum albumin showed correlations with CD4 and CD19 counts, and LBM with CD19 count. A higher CD19 count was connected with a higher red blood cell count, hemoglobin, and hematocrit. Correlations were observed between TIBC and TLC and CD3 and CD8 counts, and between serum Fe and TLC and CD3 and CD4 counts. Patients with a higher CD19 count showed a better clinical-laboratory score, especially less weakness. Patients with a higher CD4 count had less expressed insomnia. Quantities of ingested vitamins and minerals influence lymphocyte counts in the peripheral blood of PD patients. Evaluation of TLC and SLCs is helpful in monitoring the effectiveness of nutrition in these patients.

  13. Mutual interference of alpha and beta signals in counting

    International Nuclear Information System (INIS)

    Zhang Fengxiang; Ren Wei; Tang Shaohua; Han Suping; Du Xiangyang.

    1993-01-01

    When multi-wire proportional counters are used for monitoring of mixed contamination of α and β radioactivity, both of the signals should be distinguished as far as possible from requirement of radiation protection. The rules provided by the recommendation standard of International Electrotechnical Committee (IEC) and the national standard of China indicate: For fixed personal surface contamination monitoring assembly, the response of the α-counting channel to β events should be smaller than 1% of response of the α-counting channel to α events, and the response of β-counting channel to β events should be smaller than that of the response of α-counting channel to the same events. To distinguish one kind of signal from another, amplitude discrimination method is used usually. (3 figs)

  14. Beta, gamma contamination analysis of thermo luminescence dosimeter cassettes using Geiger Muller counting set up and gamma spectrometry techniques

    International Nuclear Information System (INIS)

    Prasad, S.K.; Sudheer, T.S.; Sahoo, L.; Vinayagam, Bhakti; Kamble, Mahesh; Khuspe, R.R.; Anilkumar, Rekha; Verma, K.K.

    2009-01-01

    Β-γ contamination cheek up of TLD cassettes were carried out and the isotopes found were 137 Cs, 106 Ru, 60 Co, 64 Cu, 144 Ce and 95 Nb with activity per square cm varying from 0.05-4.70 Bq/cm 2 with median value 1.3. The assessed dose in TLD was in the range of 2.10 mSv to 22.05 mSv for beta, 0.05 mSv to 5.25 mSv for gamma. The beta doses have median value of 6.19 mSv. This contamination may be due to active water contamination on TLD's of personnel working for irradiated fuel handling or work in fuel rod (under water) storage area. This gives a method to estimate skin exposure of personnel due to skin contamination during work. Chances of getting TLD's contaminated due to various reasons were studied. Contamination was found maximum inside the cassette box having area 16 cm 2 . In case of plastic pouch of TLD disc contamination was detected in three cases. Contamination level on TLD cassettes using GM counter was found in the range of 0.30-3.6 Bq/cm 2 for cassettes. By opening the window of the surveymeter contamination and field of these cassettes in closed condition were found to increase by 20% due to the measurement of beta dose. With the same condition contamination of TLD cassette in open condition was found five times more. This is due to the a-contamination which is five times more than a contamination, The most prominent isotope 137 Cs in common chemical forms are soluble in water and if inhaled or ingested are rapidly and completely absorbed in the lungs and across the gastrointestinal tract. Thus a skin contamination of most prominent isotope 137 Cs can lead to intake in addition to skin dose. Fading studies of contamination of TLD cassettes were carried out. It was found negligible after counting with GM counting set up after a period of 3 months. But one of the TLD cassettes was showing an 80% reduction of contamination after 3 months with GM counting set up, the contaminants being 141 Ce, 103 Ru and 95 Nb. The gamma peaks in the external exposure

  15. Estimation of potassium concentration in coconut water by beta radioactivity measurement

    International Nuclear Information System (INIS)

    Reddy, P.J.; Narayani, K.; Bhade, S.P.D.; Anilkumar, S.; Kolekar, R.V.; Singh, Rajvir; Pradeepkumar, K.S.

    2014-01-01

    Potassium is widely distributed in soil, in all vegetable, fruits and animal tissues. Approximately half the radioactivity found in humans comes from 40 K. Potassium is an essential element in our diet since it is required for proper nerve and muscle function, as well as for maintaining the fluid balance of cells and heart rhythm. Potassium can enter the body mainly consuming fruits, vegetables and food. Tender coconut water is consumed widely as natural refreshing drink which is rich in potassium. The simple way to determine 40 K activity is by gamma ray spectrometry. However, the low abundance of this gamma photon makes the technique less sensitive compared to gross beta measurement. Many analytical methods are reported for potassium estimation which is time consuming and destructive in nature. A unique way to estimate 40 K by beta activity is by Cerenkov Counting technique using Liquid Scintillation Analyzer. Also much lower detection limit is achieved, allowing for greater precision. In this work, we have compared two methods to arrive at the potassium concentration in tender and matured coconut water by measuring 40 K. One is non-scintillator method based on measurement of the Cerenkov radiation generated from the high-energy β of 40 K. The second method is based on beta activity measurement using low background Gas flow counter

  16. Refined tropical curve counts and canonical bases for quantum cluster algebras

    DEFF Research Database (Denmark)

    Mandel, Travis

    We express the (quantizations of the) Gross-Hacking-Keel-Kontsevich canonical bases for cluster algebras in terms of certain (Block-Göttsche) weighted counts of tropical curves. In the process, we obtain via scattering diagram techniques a new invariance result for these Block-Göttsche counts....

  17. Fixation of radioactive elements on diethylene-glycol-succinate and its use for the determination of gross activity in urine

    International Nuclear Information System (INIS)

    Hafez, M.B.; Nazmy, A.F.; Eldesoky, M.M.

    1977-01-01

    Studies are given to illustrate surface adsorption of 144 Ce, 90 Sr, 232 Th, 235 U, 239 Pu and 241 Am on diethylene-glycol-succinate, DGS. Adsorption of these elements was studied from aqueous and phosphate solutions. A procedure for the determination of gross activity in urine, based on surface adsorption on DGS is described. Groups of nine solutions, in 30 ml 1N HNO 3 , were spiked with the investigated radioactive elements (approximately 5 pCi). The pH of the solutions was adjusted to a range of 0.5 to 10 using ammonia. Each solution was passed through the column and the fixed activity was removed from the column with 50 ml of 4N HCl, followed by two washes with 10 ml of distilled water. The acid solution was evaporated to dryness for alpha- or beta-counting. The percentage fixation was determined by comparison with a standard source of the same spiked element. Adsorption was found to depend on pH, age of the tracer solution, hydrolysis state of the radioelement and the ionic strength of the solution. The adsorption phenomenon which was particularly well observed could be used as a separation stage in a method for the determination of gross activity in urine. Recoveries of about 85% were obtained. (T.G.)

  18. Monitoring of global alpha and beta radioactive level in the public water supply of Sao Paulo State, Brazil

    International Nuclear Information System (INIS)

    Peres, Ana Claudia

    2002-01-01

    The present work was based in the regulation number 1469 of Brazilian Health Ministry, of 2000, 29 th of December, that establishes the proceedings and responsibilities relatives to control and vigilance of water quality to human consumption and your gauge of potability. In the context the results of the analysis of the gross alpha and gross beta concentrations are presented. They were determined in 143 samples of drinking water supplies of Sao Paulo State in the year of 2001. The gross alpha presented concentrations ranging from <0,001 a 0,182 Bq/L, while the gross beta presented concentrations ranging from <0,001 a 0,872 Bq/L. (author)

  19. Counting efficiency for radionuclides decaying by beta and gamma-ray emission; Calculo de la eficiencia de recuento de nucleidos que experimentan desintegracion beta y desexcitacion gamma simple

    Energy Technology Data Exchange (ETDEWEB)

    Grau, A.; Garcia-Torano, E.

    1988-07-01

    In this paper, counting efficiency vs figure of merit for beta and gamma-ray emitters has been computed. It is assumed that the decay scheme has only a gamma level and the beta-ray emission may be coincident with the gamma-rays or the internal-conversion electrons. The radionuclides tabulated are: 20 {sub 0}, 20{sub p}, 28{sub A}l, 35{sub p}, 41{sub A}r, 42{sub K}, 47{sub S}e, 62{sub F}e, 66{sub C}u, 81{sub G}e, 86{sub B}b, 108{sub R}u, 112{sub p}d, 121{sub S}n(Ni), 122{sub I}n, 129{sub I}, 141{sub C}e 171{sub T}m, 194{sub O}s, 2O3{sub H}g, 205{sub H}g, 210{sub p}b, 225{sub R}a, 142{sub p}r, 151{sub S}m, 244{sub A}m(m). It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 10 cm''3. (Author) 8 refs.

  20. Cherenkov radiation effects on counting efficiency in extremely quenched liquid scintillation samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.; Rodriguez Barquero, L.

    1993-01-01

    The CIEMAT/NIST tracer method has successfully standardized nuclides with diverse quench values and decay schemes in liquid scintillation counting. However, the counting efficiency is computed inaccurately for extremely quenched samples. This article shows that when samples are extremely quenched, the counting efficiency in high-energy beta-ray nuclides depends principally on the Cherenkov effect. A new technique is described for quench determination, which makes the measurement of counting efficiency possible when scintillation counting approaches zero. A new efficiency computation model for pure beta-ray nuclides is also described. The results of the model are tested experimentally for 89 Sr, 90 Y, 36 Cl and 204 Tl nuclides with independence of the quench level. (orig.)

  1. Measurement of isotopic uranium in water for compliance monitoring by liquid scintillation counting with alpha/beta discrimination

    International Nuclear Information System (INIS)

    Venso, E.A.S.

    1993-01-01

    A simple and inexpensive method is described for analysis of uranium (U) activity and mass in water by liquid scintillation counting using α/β discrimination. This method appears to offer a solution to the need for an inexpensive protocol for monitoring U activity and mass simultaneously and an alternative to the potential inaccuracy involved when depending on the mass-to-activity conversion factor or activity screen. U is extracted virtually quantitatively into 20 ml extractive scintillator from a 1-ell aliquot of water acidified to less than pH 2. After phase separation, the sample is counted for a 20-minute screening count with a minimum detection level of 0.27 pCi ell -1 . α-particle emissions from the extracted U are counted with close to 100% efficiency with a Beckman LS6000 LL liquid scintillation counter equipped with pulse-shape discrimination electronics. Samples with activities higher than 10 pCi ell -1 are recounted for 500-1000 minutes for isotopic analysis. Isotopic analysis uses events that are automatically stored in spectral files and transferred to a computer during assay. The data can be transferred to a commercially available spreadsheet and retrieved for examination or data manipulation. Values for three readily observable spectral features can be rapidly identified by data examination and substituted into a simple formula to obtain 234 U/ 238 U ratio for most samples. U mass is calculated by substituting the isotopic ratio value into a simple equation. The utility of this method for the proposed compliance monitoring of U in public drinking water supplies was field tested with a survey of drinking water from Texas supplies that had previously been known to contain elevated levels of gross α activity. U concentrations in 32 samples from 27 drinking water supplies ranged from 0.26 to 65.5 pCi ell -1 , with seven samples exceeding the proposed Maximum Contaminant Level

  2. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  3. Spectrum library concept and pulse shape analysis in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Kaihola, L [Wallac Oy, Turku (Finland)

    1997-03-01

    Wallac introduced in 1990 a new absolute liquid scintillation counting (LSC) method, Digital Overlay Technique (DOT) to correct for quench. This method allows quantization of multilabel samples by referring to library spectra which are generated against chemical and color quench indices at the factory. The libraries can further be expanded to any beta emitter by user with a method called fine tuning, which can be carried out even with a single sample. Spectrum libraries are created over the whole spectrum range of the radionuclide and allow automatic identification of a single label beta emitting radionuclide, called Easy Count method. Another improvement in LSC is commercial introduction of Pulse Shape Analysis (PSA) in 1986 by Wallac. This method recognizes alpha particle decay by pulse shape and leads to excellent sensitivity in alpha counting because most of the background signal in LSC comprises of short or beta like pulses. PSA detects alpha events in the presence of high excess of beta activity over alphas, up to a ratio 100000 to 1. (orig.)

  4. A {beta} - {gamma} coincidence; Metodo de coincidencias {beta} - {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Agullo, F

    1960-07-01

    A {beta} - {gamma} coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from {sup 1}98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs.

  5. Beta-glucan ameliorates gamma-rays induced oxidative injury in male Swiss albino rats

    International Nuclear Information System (INIS)

    Salama, S.F.

    2011-01-01

    1,3-beta-D-Glucan is a natural polysaccharide derived from the cell walls of bakers yeast Saccharomyces cerevsiae with immunoenhancing and potent antioxidant effects. This study investigated the pathways through which beta-glucan gavage treatment (50mg/kg) exerts its effect on radiation-induced oxidative damage in male rats. Beta-glucan was given orally to male rats; 3 hours post gamma-irradiation at dose 5Gy, for 10 and 20 days post-irradiation level were assayed, being remarkable indicators in cell oxidative stress. Results pointed out that irradiation at 5Gy significantly depressed all blood parameters, such as erythrocytes count (RBCs), hemoglobin content (Hb), hematocrit value (Hct), total leucocytes count and absolute lymphocytes and neutrophils counts, blood glutathione (GSH) level and conversely elevated level of serum ascorbyl radical (AsR), product of lipid peroxidation (MDA melanodialdehyde), triglycerides and cholesterol. Total leucocytes count and absolute lymphocytes and neutrophils counts, RBCs, Hb, Hct, blood GSH and serum MDA of irradiated animals receiving beta-glucan administration were exhibited significant differences compared to the irradiated group. Marrow count and the percentage of viability and spleenocytes viability were also significantly decreased. Beta-glucan treatment accelerates recovery of cell damage induced by ionizing irradiation through its potential immune-enhancing activity and free radical scavenging ability that is partially mediated through stimulation of immunohaematological system thus could play a role in regulating irradiation complications

  6. The determination of the optimum counting conditions for a ZnS(Ag) scintillation detector

    International Nuclear Information System (INIS)

    Djurasevic, M.M.; Kandic, A.B.; Novkovic, D.N; Vukanac, I.S. . E-mail address of corresponding author: mirad@vin.bg.ac.yu; Djurasevic, M.M.)

    2005-01-01

    The methods that use scintillation counting with ZnS(Ag) scintillation detector are widely used for gross alpha activity determination. The common criteria for the selection of optimum counting condition for a ZnS(Ag) scintillation detector do not consider simultaneously operating voltage and discrimination level variation. In presented method a relationship between voltage and discrimination level is derived for counting efficiency. (author)

  7. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  8. Discrimination indices as screening tests for beta-thalassemic trait.

    Science.gov (United States)

    Ntaios, George; Chatzinikolaou, Anastasia; Saouli, Zoi; Girtovitis, Fotios; Tsapanidou, Maria; Kaiafa, Georgia; Kontoninas, Zisis; Nikolaidou, Androula; Savopoulos, Christos; Pidonia, Ifigenia; Alexiou-Daniel, Stiliani

    2007-07-01

    The two most frequent microcytic anemias are beta-thalassemic trait (beta-TT) and iron deficiency anemia (IDA). Several discrimination indices have been proposed to distinguish between these two conditions. These indices are derived from several simple red blood cell indices, like red blood cell (RBC) count, mean cell volume, and RBC distribution width (RDW), as these are provided by electronic cell counters. The purpose of the study is to examine the diagnostic accuracy of six discrimination indices in the differentiation between IDA and beta-TT. The six discrimination indices that were examined were as follows: Mentzer Index (MI), Green & King Index (G&K), RDW Index (RDWI), England & Fraser Index (E&F), RDW, and RBC count. We calculated these indices on 373 patients (205 men, 168 women) with beta-TT and 120 patients (50 men, 70 women) with IDA, as well as their sensitivity, specificity, positive and negative prognostic value, efficiency, and Youden's index (YI). G&K shows the highest reliability, followed by E&F, RBC count, MI, and RDWI. On the contrary, RDW completely failed to differentiate between IDA and beta-TT. G&K proved to be the most reliable index as it had the highest sensitivity (75.06%), efficiency (80.12%), and YI (70.86%) for the detection of beta-TT. These six discrimination indices cannot be relied on for a safe differential diagnosis between beta-TT and IDA. They do have high specificity, but their sensitivity for the detection of beta-TT is not satisfactory. Consequently, they cannot be used neither as a screening tool for beta-TT because they could result in a significant number of false negative results.

  9. Estimation of tritium trapped in the used ion exchange column resins using water as scavenger

    International Nuclear Information System (INIS)

    Kumaravel, S.; Ramakrishna, V.; Nair, B.S.K.; Ganesh, G.; Tripathi, R.M.

    2018-01-01

    Estimation of Tritium trapped in the used resins of Ion exchange (IX) columns apart from the gross beta activity in heavy water systems of Pressurised Heavy Water Reactors (PHWR) is mandatory before their disposal as radioactive waste. The gross beta activity is estimated by Gieger- Muller (GM) counter and by using gamma spectrometer. Accurate estimation of tritium activity of the resin without compromising the counting efficiency is a challenging task because, if a fixed quantity of the resin is directly added to the scintillation solution and counted on a liquid scintillation analyser (LSA), it is prone to interfere with counting efficiency drastically and results in unquantifiable errors and other practical difficulties. In this study a standard technique using light water as scavenger medium to precisely quantify the total activity of tritium trapped in the resin by a systematic approach was carried out

  10. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  11. Beta-delayed neutron decay of $^{33}$Na

    CERN Document Server

    Radivojevic, Z; Caurier, E; Cederkäll, J; Courtin, S; Dessagne, P; Jokinen, A; Knipper, A; Le Scornet, G; Lyapin, V G; Miehé, C; Nowacki, F; Nummela, S; Oinonen, M; Poirier, E; Ramdhane, M; Trzaska, W H; Walter, G; Äystö, J

    2002-01-01

    Beta-delayed neutron decay of /sup 33/Na has been studied using the on-line mass separator ISOLDE. The delayed neutron spectra were measured by time-of-flight technique using fast scintillators. Two main neutron groups at 800(60) and 1020(80) keV were assigned to the /sup 33/Na decay, showing evidence for strong feeding of states at about 4 MeV in /sup 33/Mg. By simultaneous beta - gamma -n counting the delayed neutron emission probabilities P/sub 1n/ = 47(6)% and P /sub 2n/ = 13(3)% were determined. The half-life value for /sup 33 /Na, T/sub 1/2/ = 8.0(3) ms, was measured by three different techniques, one employing identifying gamma transitions and two employing beta and neutron counting. (21 refs).

  12. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  13. In vitro proliferation of adult human beta-cells.

    Directory of Open Access Journals (Sweden)

    Sabine Rutti

    Full Text Available A decrease in functional beta-cell mass is a key feature of type 2 diabetes. Glucagon-like peptide 1 (GLP-1 analogues induce proliferation of rodent beta-cells. However, the proliferative capacity of human beta-cells and its modulation by GLP-1 analogues remain to be fully investigated. We therefore sought to quantify adult human beta-cell proliferation in vitro and whether this is affected by the GLP-1 analogue liraglutide.Human islets from 7 adult cadaveric organ donors were dispersed into single cells. Beta-cells were purified by FACS. Non-sorted cells and the beta-cell enriched ("beta-cells" population were plated on extracellular matrix from rat (804G and human bladder carcinoma cells (HTB9 or bovine corneal endothelial ECM (BCEC. Cells were maintained in culture+/-liraglutide for 4 days in the presence of BrdU.Rare human beta-cell proliferation could be observed either in the purified beta-cell population (0.051±0.020%; 22 beta-cells proliferating out of 84'283 beta-cells counted or in the non-sorted cell population (0.055±0.011%; 104 proliferating beta-cells out of 232'826 beta-cells counted, independently of the matrix or the culture conditions. Liraglutide increased human beta-cell proliferation on BCEC in the non-sorted cell population (0.082±0.034% proliferating beta-cells vs. 0.017±0.008% in control, p<0.05.These results indicate that adult human beta-cell proliferation can occur in vitro but remains an extremely rare event with these donors and particular culture conditions. Liraglutide increases beta-cell proliferation only in the non-sorted cell population and only on BCEC. However, it cannot be excluded that human beta-cells may proliferate to a greater extent in situ in response to natural stimuli.

  14. Application of PSD for low level alpha counting using liquid scintillation counting

    International Nuclear Information System (INIS)

    Krishnamachari, G.; Vaze, P.K.; Iyer, M.R.

    1989-01-01

    In the liquid scintillator the light produced by alpha particles decays differently than those produced by electrons. Pulse shape discrimination (PSD) methods are employed to estimate low levels of alpha emitting radionuclides by reducing the background due to either beta or gamma events. An attempt is being made to develop a liquid scintillation counting sytem using a simple PSD circuit to achieve a background of 0.01 counts/min. The PSD circuit is based on measuring zero cross over points to differentiate particle types. The input signal is first differentiated by a delay line and subsequently by a RC circuit. The width of the initial part of the doubly differentiated pulse is different for alpha and beta pulses. This width is converted to amplitude by a time-to-amplitude converter (TAC). The higher amplitude pulses from the TAC are due to alpha particles and they are separated by an integral discriminator. The output from the integral discriminator opens a linear gate to record the pulse height spectrum. The figure of merit of the PSD circuit and background in the alpha energy channel have been worked out using different scintillator types. (author). 4 figs

  15. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  16. Quality control of radiation counting systems and measurement of minimum detectable activity

    International Nuclear Information System (INIS)

    Song, Byoung Chul; Han, Sung Sim; Kim, Young Bok; Jee, Kwang Yong; Sohn, Se Chul

    2004-01-01

    Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the γ-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 dps within 20 confidence levels. The average alpha background level for the low background α/β counting system was 0.31 cpm and the efficiency for alpha counting was 34.38 %. The average beta background level for the α/β counting system was 1.30 cpm and the efficiency for beta counting was 46.5%. The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the γ-spectrometer was found to be 3.2 Bq/mL and 3.8 Bq/mL for the liquid scintillation counter, and 20.5 and 23.0 Bq/mL, respectively for the α and β counting system

  17. Interpretation of serum antibody response to Anoplocephala perfoliata in relation to parasite burden and faecal egg count

    DEFF Research Database (Denmark)

    Kjaer, L.N.; Lungholt, M.M.; Nielsen, M.K.

    2007-01-01

    of development and gross pathological mucosal lesions were recorded and compared with serum antibody responses and faecal egg counts. Faecal egg counts were determined in samples from A. perfoliata infected horses using a semi-quantitative centrifugation/flotation technique. Blood samples collected at slaughter...

  18. CD26 + CD4 + T cell counts and attack risk in interferon-treated multiple sclerosis

    DEFF Research Database (Denmark)

    Sellebjerg, F; Ross, C; Koch-Henriksen, Nils

    2005-01-01

    in patients with CD26 + CD4 + T cell counts above median, and this risk was independent of the risk conferred by neutralizing anti-IFN-beta antibodies. CD26 + CD4 + T cell counts may identify patients with MS at increased risk of attack during treatment with IFN-beta....... and CCR5 on T cells is altered in patients with active MS. We studied the expression of these molecules by flow cytometry in patients followed for six months during immunomodulatory treatment. In interferon (IFN)-beta-treated patients, we found that the hazard ratio for developing an attack was 28...

  19. AIRFIL: a FORTRAN program for reduction of data obtained from alpha spectrometry of perimeter air filters

    International Nuclear Information System (INIS)

    Hinton, E.R. Jr.; Howell, R.L.

    1984-03-01

    Isotopic alpha spectrometry of 238 U, 235 U, and 234 U, along with gross alpha/beta counting of perimeter air filters, is performed by the Oak Ridge Y-12 Plant Laboratory in support of the Envrirnomental Monitoring Section of the Radiation Safety Department. Weekly samples are gross alpha/beta counted and the isotopic analysis performed on quarterly composites. Calculations and data management represents a major portion of the anlaysis time when performed manually, even with a desktop calculator. In order to reduce calculation time, perform orderly data manipulation and management, reduce errors due to redundant calculations, and eliminate report typing turnaround time, a computer program (AIRFIL) has been developed that performs these functions. The program accepts data through user prompts, then calculates and prints intermediate and final data, including detection limits

  20. On the absolute measure of Beta activities; Sobre la medida absoluta de actividades Beta

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez del Rio, C; Jimenez Reynaldo, O; Rodriguez Mayquez, E

    1956-07-01

    A new method for absolute beta counting of solid samples is given. The measurements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  1. Radioisotope indicator, type BETA 2

    International Nuclear Information System (INIS)

    Duszanski, M.; Pankow, A.; Skwarczynski, B.

    1975-01-01

    The authors describe a radioisotope indicator, type BETA 2, constructed in the ZKMPW Works to be employed in mines for counting, checking, signalling the presence and positioning of cars, as well as monitoring the state of some other equipment. (author)

  2. Gross National Happiness

    DEFF Research Database (Denmark)

    Giri, Krishna Prasad; Kjær-Rasmussen, Lone Krogh

    This paper investigates practices related to the ideology of infusing Gross National Happiness (GNH) into school curriculum, the effectiveness of the meditation and mind training and the implication of GNH for school environment. It also explores how GNH ambience has been managed and practiced...... of Gross National Happiness and Educating for Gross National happiness....

  3. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  4. Design and development of multiple sample counting setup

    International Nuclear Information System (INIS)

    Rath, D.P.; Murali, S.; Babu, D.A.R.

    2010-01-01

    Full text: The analysis of active samples on regular basis for ambient air activity and floor contamination from radio chemical lab accounts for major chunk of the operational activity in Health Physicist's responsibility. The requirement for daily air sample analysis on immediate counting and delayed counting from various labs in addition to samples of smear swipe check of lab led to the urge for development of system that could cater multiple sample analysis in a time programmed manner on a single sample loading. A multiple alpha/beta counting system for counting was designed and fabricated. It has arrangements for loading 10 samples in slots in order, get counted in a time programmed manner with results displayed and records maintained in PC. The paper describes the design and development of multiple sample counting setup presently in use at the facility has resulted in reduction of man-hour consumption in counting and recording of the results

  5. Beta-adrenergic receptors of lymphocytes in children with allergic respiratory diseases

    International Nuclear Information System (INIS)

    Bittera, I.; Gyurkovits, K.; Falkay, G.; Eck, E.; Koltai, M.

    1988-01-01

    The beta-adrenergic receptor binding sites on peripheral lymphocytes in children with bronchial asthma (n = 16) and seasonal allergic rhinitis (n = 8) were examined in comparison with normal controls (n = 18) by means of 124 I-cyanopindolol. The number of beta-adrenergic receptors was significantly lower in the asthmatic group (858 +/- 460/lymphocyte) than in the controls (1564 +/- 983/lymphocyte). The value (1891 +/- 1502/lymphocyte in children with allergic rhinitis was slightly higher than that in healthy controls. Of the 24 patients suffering from allergic diseases of the lower or upper airways, the bronchial histamine provocation test was performed in 21; 16 gave positive results, while 5 were negative. No difference in beta-adrenergic receptor count was found between the histamine-positive and negative patients. Neither was there any correlation between the number of beta-adrenergic receptors and the high (16/24) and low (8/24) serum IgE concentrations found in allergic patients. The significant decrease in beta-adrenergic receptor count in asthmatic children lends support to Szentivanyi's concept. Further qualitative and quantitative analysis of lymphocyte beta-adrenergic receptors may provide an individual approach to the treatment of bronchial asthma with beta-sympathomimetic drugs

  6. A simple method for calibration of Lucas scintillation cell counting system for measurement of 226Ra and 222Rn

    Directory of Open Access Journals (Sweden)

    N.K. Sethy

    2014-10-01

    Full Text Available Known quantity of radium from high grade ore solution was chemically separated and carefully kept inside the cavity of a Lucas Cell (LC. The 222Rn gradually builds up and attain secular equilibrium with its parent 226Ra. This gives a steady count after a suitable buildup period (>25 days. This secondary source was used to calibrate the radon counting system. The method is validated in by comparison with identical measurement with AlphaGuard Aquakit. The radon counting system was used to evaluate dissolved radon in ground water sample by gross alpha counting in LC. Radon counting system measures the collected radon after a delay of >180 min by gross alpha counting. Simultaneous measurement also carried out by AlphaGuard Aquakit in identical condition. AlphaGuard measures dissolved radon from water sample by constant aeration in a closed circuit without giving any delay. Both the methods are matching with a correlation coefficient of >0.9. This validates the calibration of Lucas scintillation cell counting system by designed encapsulated source. This study provides an alternative for calibration in absence of costly Radon source available in the market.

  7. Calibration of nuclides by gamma-gamma sum peak coincidence counting

    International Nuclear Information System (INIS)

    Guevara, E.A.

    1986-01-01

    The feasibility of extending sum peak coincidence counting to the direct calibration of gamma-ray emitters having particular decay schemes was investigated, also checkings of the measurement accuracy, by comparing with more precise beta-gamma coincidence counting have been performed. New theoretical studies and experiments were developed, demonstrating the reliability of the procedure. Uncertainties of less than one percent were obtained when certain radioactive sources were measured. The application of the procedure to 60 Co, 22 Na, 47 Ca and 148 Pm was studied. Theoretical bases of sum peak coincidence counting were set in order to extend it as an alternative method for absolute activity determination. In this respect, theoretical studies were performed for positive and negative beta decay, and electron capture, either accompanied or unaccompanied by coincident gamma rays. They include decay schemes containing up to three daughter nuclide excited levels, for different geometrical configurations. Equations are proposed for a possible generalization of the procedure. (M.E.L.) [es

  8. Counting efficiency for liquid scintillator systems with a single multiplier phototube

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1984-01-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs

  9. One-loop beta functions for the orientable non-commutative Gross Neveu model TH1"-->

    Science.gov (United States)

    Lakhoua, A.; Vignes-Tourneret, F.; Wallet, J.-C.

    2007-11-01

    We compute at the one-loop order the β-functions for a renormalisable non-commutative analog of the Gross Neveu model defined on the Moyal plane. The calculation is performed within the so called x-space formalism. We find that this non-commutative field theory exhibits asymptotic freedom for any number of colors. The β-function for the non-commutative counterpart of the Thirring model is found to be non vanishing.

  10. Relationship between habitual physical activity and gross motor skills is multifaceted in 5- to 8-year-old children.

    Science.gov (United States)

    Laukkanen, A; Pesola, A; Havu, M; Sääkslahti, A; Finni, T

    2014-04-01

    Adequate motor skills are essential for children participating in age-related physical activities, and gross motor skills may play an important role for maintaining sufficient level of physical activity (PA) during life course. The purpose of this study was to examine the relationship between gross motor skills and PA in children when PA was analyzed by both metabolic- and neuromuscular-based methods. Gross motor skills (KTK--Körperkoordinationstest für Kinder and APM inventory--manipulative skill test) of 84 children aged 5-8 years (53 preschoolers, 28 girls; 31 primary schoolers, 18 girls) were measured, and accelerometer-derived PA was analyzed using in parallel metabolic counts and neuromuscular impact methods. The gross motor skills were associated with moderate-to-high neuromuscular impacts, PA of vigorous metabolic intensity, and mean level of PA in primary school girls (0.5 motor skills (0.4 motor skills and PA stressing both metabolic and neuromuscular systems in children. Furthermore, PA highly stressing neuromuscular system interacts with gross motor proficiency in girls especially. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Sources of variability in the determination by evaporation method of gross alpha activity in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, A.; Corbacho, J.A. [LARUEX, Caceres (Spain). Environmental Radioactivity Lab.

    2013-07-01

    Determining the gross alpha activity concentration of water samples is one way to screen for waters whose radionuclide content is so high that its consumption could imply surpassing the Total Indicative Dose as defined in European Directive 98/83/EC. One of the most commonly used methods to prepare the sources to measure gross alpha activity in water samples is desiccation. Its main advantages are the simplicity of the procedure, the low cost of source preparation, and the possibility of simultaneously determining the gross beta activity. The preparation of the source, the construction of the calibration curves, and the measurement procedure itself involve, however, various factors that may introduce sufficient variability into the results to significantly affect the screening process. We here identify the main sources of this variability, and propose specific procedures to follow in the desiccation process that will reduce the uncertainties, and ensure that the result is indeed representative of the sum of the activities of the alpha emitters present in the sample. (orig.)

  12. Alpha liquid scintillation counting: past, present, and future

    International Nuclear Information System (INIS)

    McDowell, W.J.

    1979-01-01

    Beta liquid scintillation counting has been used for about 30 years, and its effectiveness for alpha particles has been known for almost that long; however, the technique has not been widely applied to alpha particle detection because of poor energy resolution, high background, and variable interference from beta and gamma radiation. Beginning with the work of Horrocks in the early 1960s, improvements in energy resolution and background rejection have been made. Further developments at Oak Ridge National Laboratory over the past 10 to 12 years have resulted in improved methods of sample preparation (using liquid-liquid extraction methods to isolate the sample and introduce it into the scintillator) and better instrumentation, including electronic rejection of beta and gamma pulses. Energy resolutions of 200- to 300-keV FWHM and background counts of 0.01 cpm are now routine. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are outlined for a variety of analyses

  13. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Bonicalzi, R.M. [Seattle Central College, 1701 Broadway, Seattle, WA 98122 (United States); Aalseth, C.E.; Day, A.R.; Hoppe, E.W. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States); Mace, E.K., E-mail: Emily.Mace@pnl.gov [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States); Moran, J.J.; Overman, C.T.; Panisko, M.E.; Seifert, A. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States)

    2016-03-21

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a natural methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill of P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium-counting efficiency while minimizing radiocarbon beta-decay interference. - Highlights: • Use of a single compound (methane) for dual tritium and radiocarbon measurements. • Optimized analysis window for simultaneous tritium and radiocarbon measurement. • Allows for optimization of tritium counting in the presence of radiocarbon.

  14. Energy response of detectors to alpha/beta particles and compatibility of the equivalent factors

    International Nuclear Information System (INIS)

    Lin Bingxing; Li Guangxian; Lin Lixiong

    2011-01-01

    By measuring detect efficiency and equivalent factors of alpha/beta radiation with different energies on three types of detectors, this paper compares compatibility of their equivalent factors and discusses applicability of detectors to measuring total alpha/beta radiation. The result shows the relationship between efficiency of alpha/beta radiation and their energies on 3 types of detectors, such as scintillation and proportional and semiconductor counters, are overall identical. Alpha count efficiency display exponential relation with alpha-particle energy. While beta count efficiency display logarithm relation with beta-particle energy, but the curves appears deflection at low energy. Comparison test of energy response also shows that alpha and beta equivalent factors of scintillation and proportional counters have a good compatibility, and alpha equivalent factors of the semiconductor counters are in good agreement with those of the above two types of counters, but beta equivalent factors have obvious difference, or equivalent factors of low energy beta-particle are lower than those of other detectors. So, the semiconductor counter can not be used for measuring total radioactivity or for the measurements for the purpose of food safety. (authors)

  15. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Bonicalzi, R. M.; Aalseth, C. E.; Day, A. R.; Hoppe, E. W.; Mace, E. K.; Moran, J. J.; Overman, C. T.; Panisko, M. E.; Seifert, A.

    2016-03-01

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill of P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium counting efficiency while minimizing radiocarbon beta decay interference.

  16. Potassium analysis by beta counting using a Geiger-Mueller system

    International Nuclear Information System (INIS)

    Espana, E.; Beneitez, P.; Calderon, T.

    1993-01-01

    A technique for quantitative analysis of different soils, ceramics, feldspars and natural halide samples is presented, based on the measurement of β-activities using a Geiger-Mueller system. The system was calibrated with KCl, KC 8 H 5 O 4 , KNO 3 and K 2 SO 4 standards and a potassium content of 1% yields a net β-count rate (background subtracted) of about 55 cph. Precision values of less than ±0.4% K can be achieved in counting times of about 4 hours. The results agree with those obtained by means of other more common analytical methods such as flame photometry, atomic absorption and γ-spectrometry. In comparison with these methods, this approach is direct, precise and non-destructive, because the samples do not require prior treatment. (author) 16 refs.; 2 figs.; 6 tabs

  17. Discriminator setting and cocktail preparation for analysis of alpha and beta emitters in aqueous solution using liquid scintillation counter

    International Nuclear Information System (INIS)

    Zaini Hamzah; Masitah Alias; Zaharudin Ahmad

    2011-01-01

    Liquid scintillation counting (LSC) is not only being used to measure pure beta emitters, but it can be used to measure both alpha and beta emitters simultaneously. Measurement of alpha and beta emitters in aqueous solution is done using a single sample. For the sample preparation, colorless detergent or emulsifier was used to incorporate the water into an organic based scintillator to produce a clear homogeneous solution, since this is the best form to give the highest count rate and detection efficiency. The instrument also need some attention, where after calibration, the LSC was set for the discriminator level which is suitable for measurement of both alpha and beta radiations. In this study, the focus is on the development of the best scintillation cocktail and establishes the best discriminator setting. From this study the best proportion of scintillation cocktail is 2:4:4 for water, toluene, and Triton-N101 (emulsifier) respectively and the best discriminator setting for alpha and beta counting are 120. (author)

  18. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  19. Method of measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1980-01-01

    A novel liquid scintillation counting method of measuring the disintegration rate of a beta-emitting radionuclide is described which involves counting the sample at at least two different quench levels. (UK)

  20. Monte Carlo simulation of the spectral response of beta-particle emitters in LSC systems

    International Nuclear Information System (INIS)

    Ortiz, F.; Los Arcos, J.M.; Grau, A.; Rodriguez, L.

    1992-01-01

    This paper presents a new method to evaluate the counting efficiency and the effective spectra at the output of any dynodic stage, for any pure beta-particle emitter, measured in a liquid scintillation counting system with two photomultipliers working in sum-coincidence mode. The process is carried out by a Monte Carlo simulation procedure that gives the electron distribution, and consequently the counting efficiency, at any dynode, in response to the beta particles emitted, as a function of the figure of merit of the system and the dynodic gains. The spectral outputs for 3 H and 14 C have been computed and compared with experimental data obtained with two sets of quenched radioactive standards of these nuclides. (orig.)

  1. Recent status of the studies of nuclear masses and {beta}-decay

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Masami [Waseda Univ., Tokyo (Japan). Advanced Research Center for Science and Engineering

    1996-05-01

    The recent status of the above studies was explained, especially, nuclear masses were described from the aspect of probability theory and that of {beta}-decay suggested that the first forbidden transition was hindered between the ground states. We have to study various systematics in order to know the mass surface, Way-Yamada-Matumoto type systematics is better to check the experimental nuclear masses. The gross theory is very useful to understand the general aspect of {beta}-decay. The understanding method of mass surface, systematic check of mass and hindrance of the first forbidden transition at rank 1 were explained. (S.Y.)

  2. On the absolute measure of Beta activities

    International Nuclear Information System (INIS)

    Sanchez del Rio, C.; Jimenez Reynaldo, O.; Rodriguez Mayquez, E.

    1956-01-01

    A new method for absolute beta counting of solid samples is given. The mea surements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  3. Recent progress with digital coincidence counting

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Watt, G.C.; Alexiev, D.

    1999-01-01

    Digital Coincidence Counting (DCC) is a new technique, based on the older method of analogue coincidence counting. It has been developed by ANSTO as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue to digital converter acquisition system for collecting pulse information from a 4Π beta detector and a NaI(Tl) gamma detector. The digitised pulse information is stored on a high speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software based algorithms. The system is operational and results are now being routinely collected and analysed. Some of the early work is presented for Co-60, Na-22 and Sm-153

  4. The effects of beta-hydroxy-beta-methylbutyrate (HMB) and HMB/creatine supplementation on indices of health in highly trained athletes.

    Science.gov (United States)

    Crowe, Melissa J; O'Connor, Donna M; Lukins, Joann E

    2003-06-01

    This study aimed to investigate the effects of 6 wk oral supplementation of beta-hydroxy-beta-methylbutyrate (HMB) and HMB combined with creatine monohydrate (HMBCr) on indices of health in highly trained athletes. Elite, male rugby league players (n=28) were allocated to 1 of 3 groups: a control group (n=6), a HMB group (3 g/d; n=11), or a HMBCr group (3 g/day HMB, 3 g/d Cr; n=11). Testing prior to, and immediately following, supplementation included a full blood count, plasma testosterone and cortisol, blood electrolytes, lipids, urea and glucose, sperm count and motility, and assessment of psychological state. A 3 x 2 factorial ANOVA revealed no effect of HMB or HMBCr on any of the measured parameters except minor changes in blood bicarbonate and blood monocyte and lymphocyte counts. Blood bicarbonate was significantly decreased in the HMB post-supplementation sample compared to the control and HMBCr groups. Blood monocyte and lymphocyte counts showed no within-group changes for HMB or HMBCr supplementation but were significantly different from the control. However, the majority of these readings remained within normal range. HMB and HMBCr were concluded to have no adverse effects on the parameters evaluated in this study when taken orally by highly trained male athletes over a 6-wk period.

  5. Using Cherenkov Counting For Fast Determination of 90Sr/90Y Activity in Milk

    International Nuclear Information System (INIS)

    Tsroya, S.; Dolgin, B.; German, U.; Pelled, O.; Alfassi, Z. B.

    2014-01-01

    90Sr is one of the main long-lived fission products, and it is transferred into human body primarily by food, with milk being a substantial contributor. Due to its biochemical similarity to calcium, most strontium is efficiently incorporated into bone tissues. 90Sr is characterized by a long physical half life (28.8 y) and decays by beta particles with an Emax of 0.546 MeV to 90Y. This daughter isotope has a half life of 64 h and decays into 90Zr by beta particles with an Emax of 2.284 MeV. The milk components produce a high turbidity and light attenuation, causing a significant decrease of the counting efficiency in liquid scintillation counting (LSC) systems, mostly used for beta emitters detection. Most methods proposed in the past are time-consuming, as they are based on several stages of chemical and physical treatments, including precipitation, ashing, ion exchange and extraction (Wikins et al., 1984, Porter et al, 1961, Kimura et al., 1979). When measuring 90Sr/90Y activity by Cherenkov counting, most of the Cherenkov radiation is produced by 90Y (about 98.6%), due to the much higher energy of its beta particles relative to these from 90Sr. The counting efficiency varies strongly with color quenching, at a greater extent than in standard liquid scintillation counting (L'Annunziata, 2012), and therefore the quench correction is critical. The ‘‘external source area ratio’’ (ESAR) quench correction method was applied to measure 90Sr/90Y activities in aqueous samples with a wide range of quenching levels (Tsroya et al., 2009). This method was proved to be superior to all other quench correction methods (Tsroya et al., 2012) and is applicable also for determination of 90Sr/90Y in human urine (Tsroya et al., 2013). In the present work the applicability of the ESAR method to measurement of 90Sr/90Y activities in milk and some of its products was investigated

  6. NM Gross Receipts Baseline

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  7. Beta decay to the second 2+ excited state of 122Te

    International Nuclear Information System (INIS)

    Hayashi, Takeo; Yamada, Shigeru

    1976-01-01

    The first-forbidden beta transition in Sb-122 was studied by the angular correlation experiment and the beta-spectra. The special precautions were paid for counting the beta particles having energy lower than 750 keV in the beta-gamma angular correlation measurement. The sources of Sb-122 were obtained by irradiating enriched Sb-121 in the Kyoto University reactor. The reduced beta coefficient R(E) was obtained from the angular correlation function. The beta spectrum measurement was performed with a sector type double focusing beta-ray spectrometer. The R(E) values for the beta transitions were analyzed by using the simplex method as used by Manthuruthil and Poirier to compare the angular correlation data with the exact formula given by Morita and Morita. Sets of the nuclear matrix parameters thus obtained show that the condition for the cancellation effect is satisfied in the beta transition. (Kato, T.)

  8. Trends in physical activity, health-related fitness, and gross motor skills in children during a two-year comprehensive school physical activity program.

    Science.gov (United States)

    Brusseau, Timothy A; Hannon, James C; Fu, You; Fang, Yi; Nam, Kahyun; Goodrum, Sara; Burns, Ryan D

    2018-01-06

    The purpose of this study was to examine the trends in school-day step counts, health-related fitness, and gross motor skills during a two-year Comprehensive School Physical Activity Program (CSPAP) in children. Longitudinal trend analysis. Participants were a sample of children (N=240; mean age=7.9±1.2 years; 125 girls, 115 boys) enrolled in five low-income schools. Outcome variables consisted of school day step counts, Body Mass Index (BMI), estimated VO 2 Peak , and gross motor skill scores assessed using the Test of Gross Motor Development-3rd Edition (TGMD-3). Measures were collected over a two-year CSPAP including a baseline and several follow-up time-points. Multi-level mixed effects models were employed to examine time trends on each continuous outcome variable. Markov-chain transition models were employed to examine time trends for derived binary variables for school day steps, BMI, and estimated VO 2 Peak . There were statistically significant time coefficients for estimated VO 2 Peak (b=1.10mL/kg/min, 95% C.I. [0.35mL/kg/min-2.53mL/kg/min], p=0.009) and TGMD-3 scores (b=7.8, 95% C.I. [6.2-9.3], p<0.001). There were no significant changes over time for school-day step counts or BMI. Boys had greater change in odds of achieving a step count associating with 30min of school day MVPA (OR=1.25, 95% C.I. [1.02-1.48], p=0.044). A two-year CSPAP related to increases in cardio-respiratory endurance and TGMD-3 scores. School day steps and BMI were primarily stable across the two-year intervention. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  10. Beta 2-adrenergic receptors are colocalized and coregulated with whisker barrels in rat somatosensory cortex

    International Nuclear Information System (INIS)

    Vos, P.; Kaufmann, D.; Hand, P.J.; Wolfe, B.B.

    1990-01-01

    Autoradiography has been used to visualize independently the subtypes of beta-adrenergic receptors in rat somatosensory cortex. Beta 2-adrenergic receptors, but not beta 1-adrenergic receptors colocalize with whisker barrels in this tissue. Thus, each whisker sends a specific multisynaptic pathway to the somatosensory cortex that can be histochemically visualized and only one subtype of beta-adrenergic receptor is specifically associated with this cortical representation. Additionally, neonatal lesion of any or all of the whisker follicles results in loss of the corresponding barrel(s) as shown by histochemical markers. This loss is paralleled by a similar loss in the organization of beta 2-adrenergic receptors in the somatosensory cortex. Other results indicate that these beta 2-adrenergic receptors are not involved in moment-to-moment signal transmission in this pathway and, additionally, are not involved in a gross way in the development of whisker-barrel array

  11. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  12. Bayesian approach in MN low dose of radiation counting

    International Nuclear Information System (INIS)

    Serna Berna, A.; Alcaraz, M.; Acevedo, C.; Navarro, J. L.; Alcanzar, M. D.; Canteras, M.

    2006-01-01

    The Micronucleus assay in lymphocytes is a well established technique for the assessment of genetic damage induced by ionizing radiation. Due to the presence of a natural background of MN the net MN is obtained by subtracting this value to the gross value. When very low doses of radiation are given the induced MN is close even lower than the predetermined background value. Furthermore, the damage distribution induced by the radiation follows a Poisson probability distribution. These two facts pose a difficult task to obtain the net counting rate in the exposed situations. It is possible to overcome this problem using a bayesian approach, in which the selection of a priori distributions for the background and net counting rate plays an important role. In the present work we make a detailed analysed using bayesian theory to infer the net counting rate in two different situations: a) when the background is known for an individual sample, using exact value value for the background and Jeffreys prior for the net counting rate, and b) when the background is not known and we make use of a population background distribution as background prior function and constant prior for the net counting rate. (Author)

  13. Analysis of low energy beta-emitters

    International Nuclear Information System (INIS)

    Murphy, D.L.

    1979-10-01

    A survey was made of the instruments used for the determination of low energy beta radioactivity. Techniques commonly used are gas flow proportional counting, liquid scintillation counting, solid scintillation counting, and internal ionization chamber counting, solid state detector counting, and radiochemical separation followed by counting using one of the preceeding techniques. The first four techniques were examined and compared with each other. The sensitivities of the techniques were compared on the basis of the detection limits quoted for instruments described in the technical and reviewed literature. The detection limits were then related to the occupational and public individual maximum levels for air and water. Attention is focused primarily on the continuous monitoring of air for 3 H and 85 Kr, a medium energy β-emitter. It is clear that several continuous air monitoring instruments are readily available for measuring low energy β concentrations, even in presence of certain other activity, at occupational levels. However, these instruments do not typically have sensitivities comparable to the public individual levels. Moreover, their capabilities for giving results in real time and for differentiating among the radionuclides actually present is limited

  14. Experimental investigation of mass efficiency curve for alpha radioactivity counting using a gas-proportional detector

    International Nuclear Information System (INIS)

    Semkow, T.M.; Bari, A.; Parekh, P.P.; Haines, D.K.; Gao, H.; Bolden, A.N.; Dahms, K.S.; Scarpitta, S.C.; Thern, R.E.; Velazquez, S.

    2004-01-01

    Gross α counting of evaporated water residues offers a simple method for screening α radioactivity in water for both public health and emergency purposes. The evaporation process for water has been improved by using a combination of roughening of the surface of counting planchettes, two-stage evaporation, and temperature-controlled block heating. The efficiency of the gas-proportional detector for α-particle detection in water residues was studied as a function of sample mass-thickness in the range between 0.1 and 13 mg cm -2 . The effect of α energy on the efficiency, as well as moisture absorption on the samples, were studied using 230 Th, 238 U, 239 Pu, 241 Am, and 244 Cm radionuclides. Also, α-to-β crosstalk was investigated as a function of sample mass for 230 Th, 239 Pu, 210 Po, 241 Am, and 244 Cm. The improved method can also be applied for gross α detection in biological fluids

  15. Activity level of gross α and gross β in airborne aerosol samples around the Qinshan NPP

    International Nuclear Information System (INIS)

    Chen Bin; Ye Jida; Chen Qianyuan; Wu Xiaofei; Song Weili; Wang Hongfeng

    2007-01-01

    The monitoring results of gross α and gross 13 activity from 2001 to 2005 for environmental airborne aerosol samples around the Qinshan NPP base are presented in this paper. A total of 170 aerosol samples were collected from monitoring sites of Caichenmen village, Qinlian village, Xiajiawan village and Yangliucun village around the Qinshan NPP base. The measured specific activity of gross α and gross β are in the range of 0.02-0.38 mBq/m 3 and 0.10-1.81 mBq/m 3 , respectively, with an average of 0.11 mBq/m 3 and 0.45mBq/m 3 , respectively. They are lower than the average of 0.15 mBq/m 3 and 0.52 mBq/m 3 , of reference site at Hangzhou City. It is indicated that the specific activity of gross α and gross β for environmental aerosol samples around the Qinshan NPP base had not been increased in normal operating conditions of the NPP. (authors)

  16. Determination of beta attenuation coefficients by means of timing method

    International Nuclear Information System (INIS)

    Ermis, E.E.; Celiktas, C.

    2012-01-01

    Highlights: ► Beta attenuation coefficients of absorber materials were found in this study. ► For this process, a new method (timing method) was suggested. ► The obtained beta attenuation coefficients were compatible with the results from the traditional one. ► The timing method can be used to determine beta attenuation coefficient. - Abstract: Using a counting system with plastic scintillation detector, beta linear and mass attenuation coefficients were determined for bakelite, Al, Fe and plexiglass absorbers by means of timing method. To show the accuracy and reliability of the obtained results through this method, the coefficients were also found via conventional energy method. Obtained beta attenuation coefficients from both methods were compared with each other and the literature values. Beta attenuation coefficients obtained through timing method were found to be compatible with the values obtained from conventional energy method and the literature.

  17. Card controlled beta backscatter thickness measuring instrument

    International Nuclear Information System (INIS)

    Schlesinger, J.

    1978-01-01

    An improved beta backscatter instrument for the nondestructive measurement of the thickness of thin coatings on a substrate is described. Included therein is the utilization of a bank of memory stored data representative of isotope, substrate, coating material and thickness range characteristics in association with a control card having predetermined indicia thereon selectively representative of a particular isotope, substrate material, coating material and thickness range for conditioning electronic circuit means by memory stored data selected in accord with the predetermined indicia on a control card for converting backscattered beta particle counts into indicia of coating thickness

  18. Water radiological sanitary control of Veracruz State; Control sanitario radiologico de agua del Estado de Veracruz

    Energy Technology Data Exchange (ETDEWEB)

    Carreon G, E.; Vazquez C, J. A.; Aguilar P, M. del C.; Parissi C, A., E-mail: eulaliacarreon@gmail.com [Laboratorio Estatal de Salud Publica, Eucalipto Mza. 12, Lote 7, Corredor Industrial Bruno Pagliai, 91697 Veracruz (Mexico)

    2014-10-15

    This work is carried out in Veracruz State covering over 11 jurisdictions of the State (Panuco, Tuxpan, Poza Rica, Martinez de la Torre, Xalapa, Cordoba, Orizaba, Veracruz, Cosamaloapan, San Andres Tuxtla and Coatzacoalcos). The sampling was realized in a period from 2009 to 2013 analyzing home drinking water, supply sources and wells, the sampling was done by the sanitary checkers of different jurisdictions with approved methods and the methodology was validated at the State Laboratory of Public Health. 1637 samples were analyzed by counting equipment Tennelec Canberra series 5 and a gas supply system P-10 with calibration curves for alpha and gross beta. The results of measurements ranging from 0.07 to 0.25 Bq/L in the activity concentration gross alpha annual average, an gross beta were from 0.12 to 0.17 Bq/L in the activity concentration gross beta annual average, and with a concentration range of alpha activity up to 0.62 and a minimum 0.02, and the concentration of beta activity of a maximum value 1.54 and a minimum 0.02, taking also as resulted in five years of analysis only 1.16% of the analyzed samples (19 samples) showed a value of alpha activity concentration above the minimum detectable concentration and 62.43% (1022 samples) of the analyzed samples showed a value of beta activity concentration above the minimum detectable concentration, is also clear that the results of the sanitary jurisdictions of Panuco and Tuxpan not have corresponding activity values for the years 2009, 2011-2013 except 2010. We can conclude that the regular measurements of alpha and gross beta activity in water are invaluable for timely detection of radioactive contamination. (Author)

  19. Water radiological sanitary control of Veracruz State

    International Nuclear Information System (INIS)

    Carreon G, E.; Vazquez C, J. A.; Aguilar P, M. del C.; Parissi C, A.

    2014-10-01

    This work is carried out in Veracruz State covering over 11 jurisdictions of the State (Panuco, Tuxpan, Poza Rica, Martinez de la Torre, Xalapa, Cordoba, Orizaba, Veracruz, Cosamaloapan, San Andres Tuxtla and Coatzacoalcos). The sampling was realized in a period from 2009 to 2013 analyzing home drinking water, supply sources and wells, the sampling was done by the sanitary checkers of different jurisdictions with approved methods and the methodology was validated at the State Laboratory of Public Health. 1637 samples were analyzed by counting equipment Tennelec Canberra series 5 and a gas supply system P-10 with calibration curves for alpha and gross beta. The results of measurements ranging from 0.07 to 0.25 Bq/L in the activity concentration gross alpha annual average, an gross beta were from 0.12 to 0.17 Bq/L in the activity concentration gross beta annual average, and with a concentration range of alpha activity up to 0.62 and a minimum 0.02, and the concentration of beta activity of a maximum value 1.54 and a minimum 0.02, taking also as resulted in five years of analysis only 1.16% of the analyzed samples (19 samples) showed a value of alpha activity concentration above the minimum detectable concentration and 62.43% (1022 samples) of the analyzed samples showed a value of beta activity concentration above the minimum detectable concentration, is also clear that the results of the sanitary jurisdictions of Panuco and Tuxpan not have corresponding activity values for the years 2009, 2011-2013 except 2010. We can conclude that the regular measurements of alpha and gross beta activity in water are invaluable for timely detection of radioactive contamination. (Author)

  20. Assessment of environmental radioactivity for Sanliurfa region of southeastern Turkey

    International Nuclear Information System (INIS)

    Bozkurt, Ahmet; Yorulmaz, Nuri; Kam, Erol; Karahan, Gursel; Osmanlioglu, Ahmet Erdal

    2007-01-01

    This study assesses the level of background radiation for Sanliurfa province of southeastern Turkey. Measurements of outdoor gamma radiation (of terrestrial and cosmic origin) in air were performed at 112 locations using a plastic scintillator and the average absorbed dose was found as 60.9 nGy/h (corresponding to an effective dose of 74.7μSv/y). The radionuclide activity concentrations in 45 soil samples collected from the study area were measured through gamma-ray spectrometry and the average activities were determined as 20.8, 24.95 and 298.6 for the natural radionuclides 238 U, 232 Th and 40 K, respectively, and 9.08 Bq/kg for the fission product 137 Cs. The natural radioactivity sources resulted in an effective dose of 46.9μSv/y. The radioactivity levels of 53 drinking water samples were measured as 0.038 Bq/l for gross-alpha activity and 0.1324 Bq/l for gross-beta activity using gross-alpha and gross-beta counting methods (equivalent to an effective dose of 7.76μSv/y). When compared with the data available for other Turkish cities, the outdoor gamma doses and soil radioactivity concentrations obtained in this study indicate a background radiation level that falls within natural limits. On the other hand, the measured gross-alpha and -beta activities in drinking water are relatively higher

  1. Air and smear sample calculational tool for Fluor Hanford Radiological control

    International Nuclear Information System (INIS)

    BAUMANN, B.L.

    2003-01-01

    A spreadsheet calculation tool was developed to automate the calculations performed for determining the concentration of airborne radioactivity and smear counting as outlined in HNF--13536, Section 5.2.7, ''Analyzing Air and Smear Samples''. This document reports on the design and testing of the calculation tool. Radiological Control Technicians (RCTs) will save time and reduce hand written and calculation errors by using an electronic form for documenting and calculating work place air samples. Current expectations are RCTs will perform an air sample and collect the filter or perform a smear for surface contamination. RCTs will then survey the filter for gross alpha and beta/gamma radioactivity and with the gross counts utilize either hand calculation method or a calculator to determine activity on the filter. The electronic form will allow the RCT with a few key strokes to document the individual's name, payroll, gross counts, instrument identifiers; produce an error free record. This productivity gain is realized by the enhanced ability to perform mathematical calculations electronically (reducing errors) and at the same time, documenting the air sample

  2. Expression and autoregulation of transforming growth factor beta receptor mRNA in small-cell lung cancer cell lines

    DEFF Research Database (Denmark)

    Nørgaard, P; Spang-Thomsen, M; Poulsen, H S

    1996-01-01

    In small-cell lung cancer cell lines resistance to growth inhibition by transforming growth factor (TGF)-beta 1, was previously shown to correlate with lack of TGF-beta receptor I (RI) and II (RII) proteins. To further investigate the role of these receptors, the expression of mRNA for RI, RII...... and beta-glycan (RIII) was examined. The results showed that loss of RII mRNA correlated with TGF-beta 1 resistance. In contrast, RI-and beta-glycan mRNA was expressed by all cell lines, including those lacking expression of these proteins. According to Southern blot analysis, the loss of type II m......RNA was not due to gross structural changes in the gene. The effect of TGF-beta 1 on expression of TGF-beta receptor mRNA (receptor autoregulation) was examined by quantitative Northern blotting in four cell lines with different expression of TGF-beta receptor proteins. In two cell lines expressing all three TGF...

  3. 26 CFR 1.61-1 - Gross income.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Gross income. 1.61-1 Section 1.61-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Definition of Gross Income, Adjusted Gross Income, and Taxable Income § 1.61-1 Gross...

  4. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    Mirashi, N.N.; Chander, Keshav; Aggarwal, S.K.

    2000-12-01

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  5. The ionization quench factor in liquid-scintillation counting standardizations

    CERN Document Server

    Grau-Malonda, A

    1999-01-01

    We present a new detailed analysis of the ionization quench function Q(E) used in calculating the counting efficiency in liquid-scintillation counting (LSC), which shows that Q(0)=1, and permits one to derive Q(E) as a function of the electron energy and the parameter kB. The coefficients are tabulated by applying a new empirical formula of Q(E) for kB values in the range between 0.001 and 0.20 gMeV sup - sup 1 cm sup - sup 2. We demonstrate the convenience of applying sup 3 H and sup 5 sup 4 Mn for beta-ray and electron capture standardizations, respectively.

  6. Beta-decay and decay heat. Summary report of consultants' meeting

    International Nuclear Information System (INIS)

    Nicols, A.L.

    2006-01-01

    Experts on decay data and decay heat calculations participated in a Consultants' Meeting organized at IAEA Headquarters on 12-14 December 2005. Debate focused on the validation of decay heat calculations as a function of cooling time for fuel irradiated in power reactors through comparisons with experimental benchmark data. Both the current understanding and quantification of mean beta and gamma decay energies were reviewed with respect to measurements and the Gross Theory of Beta Decay. Particular emphasis was placed on the known development of total absorption gamma-ray spectroscopy (TAGS), and detailed discussions took place to formulate the measurement requirements for mean beta and gamma data of individual radionuclides. This meeting was organized in cooperation with the OECD/NEA Working Party for Evaluation and Cooperation (WPEC). Proposals and recommendations were made to resolve particular difficulties, and an initial list of fission products was produced for TAGS studies. The discussions, conclusions and recommendations of the meeting are briefly described in this report. (author)

  7. Set of counts by scintillations for atmospheric samplings; Ensemble de comptages par scintillations pour prelevements atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Appriou, D.; Doury, A.

    1962-07-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies.

  8. Xe isotope detection and discrimination using beta spectroscopy with coincident gamma spectroscopy

    Science.gov (United States)

    Reeder, P. L.; Bowyer, T. W.

    1998-02-01

    Beta spectroscopic techniques show promise of significant improvements for a beta-gamma coincidence counter that is part of a system for analyzing Xe automatically separated from air. The previously developed counting system for 131mXe, 133mXe, 133gXe, and 135gXe can be enhanced to give additional discrimination between these Xe isotopes by using the plastic scintillation sample cell as a beta spectrometer to resolve the conversion electron peaks. The automated system will be a key factor in monitoring the Comprehensive Test Ban Treaty.

  9. Improving gross count gamma-ray logging in uranium mining with the NGRS probe

    Directory of Open Access Journals (Sweden)

    Carasco C.

    2018-01-01

    Full Text Available AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration measurement by means of gamma ray logging. The determination of uranium concentration in boreholes is performed with the Natural Gamma Ray Sonde (NGRS based on a NaI(Tl scintillation detector. The total gamma count rate is converted into uranium concentration using a calibration coefficient measured in concrete blocks with known uranium concentration in the AREVA Mines calibration facility located in Bessines, France. Until now, to take into account gamma attenuation in a variety of boreholes diameters, tubing materials, diameters and thicknesses, filling fluid densities and compositions, a semi-empirical formula was used to correct the calibration coefficient measured in Bessines facility. In this work, we propose to use Monte Carlo simulations to improve gamma attenuation corrections. To this purpose, the NGRS probe and the calibration measurements in the standard concrete blocks have been modeled with MCNP computer code. The calibration coefficient determined by simulation, 5.3 s-1.ppmU-1 ± 10%, is in good agreement with the one measured in Bessines, 5.2 s-1.ppmU-1. Based on the validated MCNP model, several parametric studies have been performed. For instance, the rock density and chemical composition proved to have a limited impact on the calibration coefficient. However, gamma self-absorption in uranium leads to a nonlinear relationship between count rate and uranium concentration beyond approximately 1% of uranium weight fraction, the underestimation of the uranium content reaching more than a factor 2.5 for a 50 % uranium weight fraction. Next steps will concern parametric studies with different tubing materials, diameters and thicknesses, as well as different borehole filling fluids representative of real measurement conditions.

  10. Improving gross count gamma-ray logging in uranium mining with the NGRS probe

    Science.gov (United States)

    Carasco, C.; Pérot, B.; Ma, J.-L.; Toubon, H.; Dubille-Auchère, A.

    2018-01-01

    AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration measurement by means of gamma ray logging. The determination of uranium concentration in boreholes is performed with the Natural Gamma Ray Sonde (NGRS) based on a NaI(Tl) scintillation detector. The total gamma count rate is converted into uranium concentration using a calibration coefficient measured in concrete blocks with known uranium concentration in the AREVA Mines calibration facility located in Bessines, France. Until now, to take into account gamma attenuation in a variety of boreholes diameters, tubing materials, diameters and thicknesses, filling fluid densities and compositions, a semi-empirical formula was used to correct the calibration coefficient measured in Bessines facility. In this work, we propose to use Monte Carlo simulations to improve gamma attenuation corrections. To this purpose, the NGRS probe and the calibration measurements in the standard concrete blocks have been modeled with MCNP computer code. The calibration coefficient determined by simulation, 5.3 s-1.ppmU-1 ± 10%, is in good agreement with the one measured in Bessines, 5.2 s-1.ppmU-1. Based on the validated MCNP model, several parametric studies have been performed. For instance, the rock density and chemical composition proved to have a limited impact on the calibration coefficient. However, gamma self-absorption in uranium leads to a nonlinear relationship between count rate and uranium concentration beyond approximately 1% of uranium weight fraction, the underestimation of the uranium content reaching more than a factor 2.5 for a 50 % uranium weight fraction. Next steps will concern parametric studies with different tubing materials, diameters and thicknesses, as well as different borehole filling fluids representative of real measurement conditions.

  11. Sensitivity of NEXT-100 to neutrinoless double beta decay

    CERN Document Server

    Martín-Albo, J.; Ferrario, P.; Nebot-Guinot, M.; Gómez-Cadenas, J.J.; Álvarez, V.; Azevedo, C.D.R.; Borges, F.I.G.; Cárcel, S.; Cebrián, S.; Cervera, A.; Conde, C.A.N.; Díaz, J.; Diesburg, M.; Esteve, R.; Fernandes, L.M.P.; Ferreira, A.L.; Freitas, E.D.C.; Gehman, V.M.; Goldschmidt, A.; González-Díaz, D.; Gutiérrez, R.M.; Henriques, C.A.O.; Hernando Morata, J.A.; Labarga, L.; Laing, A.; Lebrun, P.; Liubarsky, I.; López-March, N.; Lorca, D.; Losada, M.; Martínez-Lema, G.; Martínez, A.; Miller, T.; Monrabal, F.; Monserrate, M.; Monteiro, C.M.B.; Mora, F.J.; Moutinho, L.M.; Novella, P.; Nygren, D.; Para, A.; Perez, J.; Perez Aparicio, J.L.; Querol, M.; Renner, J.; Ripoll, L.; Rodríguez, J.; Santos, F.P.; dos Santos, J.M.F.; Serra, L.; Shuman, D.; Simón, A.; Sofka, C.; Sorel, M.; Stiegler, T.; Toledo, J.F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J.F.C.A.; Villar, J.A.; Webb, R.; White, J.T.; Yahlali, N.; Yepes-Ramírez, H.; Hauptman, J.

    2016-01-01

    NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta decay of Xe-136. The detector possesses two features of great value in neutrinoless double beta decay searches: very good energy resolution (better than 1% FWHM at the Q value of Xe-136) and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Detailed Monte Carlo detector simulations and material-screening measurements predict a background rate for NEXT-100 of at most 0.0004 counts/(keV kg yr). Accordingly, the detector will reach a sensitivity to the neutrinoless double beta decay half-life of 6.E25 years after running for 3 effective years.

  12. 17-beta-estradiol upregulates the stress response in Candida albicans: implications for microbial virulence.

    OpenAIRE

    O'Connor, C; Essmann, M; Larsen, B

    1998-01-01

    OBJECTIVE: The influence of 17-beta-estradiol on the stress response of Candida albicans was studied. METHODS: The survival of clinical isolates of C. albicans treated with 17-beta-estradiol after heat and oxidative stress was measured by viable plate counts. Cellular proteins were analyzed via SDS-PAGE. RESULTS: The heat stress response induced by 17-beta-estradiol in C. albicans grown at 25 degrees C protected the organisms against the lethal temperature of 48.5 degrees C, as shown by viabl...

  13. Absorption and backscatter of internal conversion electrons in the measurements of surface contamination of 137Cs

    International Nuclear Information System (INIS)

    Yunoki, A.; Kawada, Y.; Yamada, T.; Unno, Y.; Sato, Y.; Hino, Y.

    2013-01-01

    We measured 4π and 2π counting efficiencies for internal conversion electrons (ICEs), gross β-particles and also β-rays alone with various source conditions regarding absorber and backing foil thickness using e-X coincidence technique. Dominant differences regarding the penetration, attenuation and backscattering properties among ICEs and β-rays were revealed. Although the abundance of internal conversion electrons of 137 Cs- 137 Ba is only 9.35%, 60% of gross counts may be attributed to ICEs in worse source conditions. This information will be useful for radionuclide metrology and for surface contamination monitoring. - Highlights: • Counting efficiencies for internal conversion electrons from 137 Cs were measured, and compared with those for β-rays. • Electron-X coincidence technique was employed. • A thin NaI(Tl) scintillation detector was used for X-ray detection. • Backscattering fractions of electrons and beta particles were studied by similar experiments

  14. $\\beta$-delayed fission in proton-rich nuclei in the lead region

    CERN Document Server

    AUTHOR|(CDS)2085005; Huyse, Mark; Popescu, Lucia

    Nuclear fission is the breakup of an atomic nucleus into two (sometimes three) fragments, thereby releasing a large amount of energy. Soon after its discovery in the late 1930’s, the gross properties of the fission phenomenon were explained by macroscopic nuclear models. Certain features however, such as asymmetric fission-fragment mass distributions in the actinide region, require the inclusion of microscopic effects. This interplay of the microscopic motion of individual nucleons on this macroscopic process is, until today, not yet fully understood. The phenomenon of fission has therefore been of recurring interest for both theoretical and experimental studies. This thesis work focuses on the $\\beta$-delayed fission ($\\beta$DF) process, an excellent tool to study low-energy fission of exotic nuclei, which was discovered in 1966 in the actinide region. In this two-step process, a precursor nucleus first undergoes $\\beta$-decay to an excited level in the daughter nucleus, which may subsequently fission. Rec...

  15. Validating the Rett Syndrome Gross Motor Scale

    DEFF Research Database (Denmark)

    Downs, Jenny; Stahlhut, Michelle; Wong, Kingsley

    2016-01-01

    .93-0.98). The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice......Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated...... the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age...

  16. Method of measuring the disinteration rate of beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1977-01-01

    A method of measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample by counting at least two differently quenched versions of the sample is described. In each counting operation the sample is counted in the presence of and in the absence of a standard radioactive source. A pulse height (PH) corresponding to a unique point on the pulse height spectrum generated in the presence of the standard is determined. A zero threshold sample count rate (CPM) is derived by counting the sample once in a counting window having a zero threshold lower limit. Normalized values of the measured pulse heights (PH) are developed and correlated with the corresponding pulse counts (CPM) to determine the pulse count for a normalized pulse height value of zero and hence the sample disintegration rate

  17. Simple counting technique for measuring mixtures of two pure beta-emitting radionuclides

    CSIR Research Space (South Africa)

    Van Wyngaardt, WM

    2006-08-01

    Full Text Available on counting statistics. The method is demonstrated experimentally for various mixture combinations of C-14 and Ni-63. It is shown that the accuracy of the technique can be enhanced by improving the determination of the figure-of-merit....

  18. Optimization of plastic scintillator thicknesses for online beta/gamma detection

    Directory of Open Access Journals (Sweden)

    Pourtangestani K.

    2012-04-01

    Full Text Available For efficient beta detection in a mixed beta gamma field, Monte Carlo simulation models have been built to optimize the thickness of a plastic scintillator, used in a whole body monitor. The simulation has been performed using the MCNP/X code for different thicknesses of plastic scintillator from 150 μm to 600 μm. The relationship between the thickness of the scintillator and the efficiency of the detector has been analyzed. For 150 μm thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 μm to 500 μm has been found to be the optimum thickness for high efficiency beta detection in the presence of low energy gamma-rays.

  19. NM Gross Receipts January - June 2012

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  20. NM Gross Receipts July - December 2013

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  1. NM Gross Receipts January - June 2014

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  2. NM Gross Receipts July - December 2012

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  3. NM Gross Receipts January - June 2013

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  4. NM Gross Receipts January - June 2011

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  5. Method validation to determine total alpha beta emitters in water samples using LSC

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.; Al-akel, B.; Saaid, S.

    2006-06-01

    In this work a method was validated to determine gross alpha and beta emitters in water samples using liquid scintillation counter. 200 ml of water from each sample were evaporated to 20 ml and 8 ml of them were mixed with 12 ml of the suitable cocktail to be measured by liquid scintillation counter Wallac Winspectral 1414. The lower detection limit by this method (LDL) was 0.33 DPM for total alpha emitters and 1.3 DPM for total beta emitters. and the reproducibility limit was (± 2.32 DPM) and (±1.41 DPM) for total alpha and beta emitters respectively, and the repeatability limit was (±2.19 DPM) and (±1.11 DPM) for total alpha and beta emitters respectively. The method is easy and fast because of the simple preparation steps and the large number of samples that can be measured at the same time. In addition, many real samples and standard samples were analyzed by the method and showed accurate results so it was concluded that the method can be used with various water samples. (author)

  6. Method for measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    1977-01-01

    A method of measuring the distintegration rate of a beta-emitting radionuclide in a liquid sample by counting at least two differently quenched versions of the sample. In each counting operation the sample is counted in the presence of and in the absence of a standard radioactive source. A pulse height (PH) corresponding to a unique point on the pulse height spectrum generated in the presence of the standard is determined. A zero threshold sample count rate (CPM) is derived by counting the sample once in a counting window having a zero threshold lower limit. Normalized values of the measured pulse heights (PH) are developed and correlated with the corresponding counts (CPM) to determine the pulse count for a normalized pulse height value of zero and hence the sample disintegration rate

  7. SCINFI II A program to calculate the standardization curve in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1985-07-01

    A code, SCINFI II, written in BASIC, has been developed to compute the efficiency-quench standardization curve for any beta radionuclide. The free parameter method has been applied. The program requires the standardization curve for 3{sup H} and the polynomial or tabulated relating counting efficiency as figure of merit for both 3{sup H} and the problem radionuclide. The program is applied to the computation, of the counting efficiency for different values of quench when the problem is 14{sup C}. The results of four different computation methods are compared. (Author) 17 refs.

  8. SCINFI II A program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1985-01-01

    A code, SCINFI II, written in BASIC, has been developed to compute the efficiency-quench standardization curve for any beta radionuclide. The free parameter method has been applied. The program requires the standardization curve for 3 H and the polynomial or tabulated relating counting efficiency as figure of merit for both 3 H and the problem radionuclide. The program is applied to the computation, of the counting efficiency for different values of quench when the problem is 14 C . The results of four different computation methods are compared. (Author) 17 refs

  9. Validation of the BetaStar® Advanced for Beta-lactams Test Kit for the Screening of Bulk Tank and Tanker Truck Milks for the Presence of Beta-lactam Drug Residues.

    Science.gov (United States)

    Denhartigh, Andrew; Reynolds, Lindsay; Palmer, Katherine; Klein, Frank; Rice, Jennifer; Rejman, John J

    2018-05-18

    A validation study was conducted for an immunochromatographic method (BetaStar ® Advanced for Beta-lactams) for the detection of beta-lactam residues in raw, commingled bovine milk. The assay detected amoxicillin, ampicillin, cloxacillin, penicillin, cephapirin, and ceftiofur below the U.S. Food and Drug Administration tolerance levels but above the maximum sensitivity thresholds established by the National Conference on Interstate Milk Shipments. The results of internal and independent laboratory dose-response studies employing spiked samples were in agreement. The test detected all six drugs at the approximate 90/95% sensitivity levels in milk from cows treated with each drug. Selectivity of the assay was 100%, as no false-positive results were obtained in testing 1148 control milk samples. Testing the estimated 90/95% sensitivity level for amoxicillin (8.5 ppb), ampicillin (6.9 ppb), cloxacillin (8.9 ppb), penicillin (4.2 ppb), and cephapirin (17.6 ppb), and at 100 ppb for each antibiotic, resulted in 94-100% positive tests for each of the beta-lactam drugs. The results of ruggedness experiments established the operating parameter tolerances for the assay. Cross-reactivity testing established that the assay detects other certain beta-lactam drugs, but it does not cross-react with any of 30 drugs belonging to seven different drug classes. Abnormally high bacterial or somatic cell counts in raw milk produced no assay interference.

  10. Analysis of reactor-neutrino spectra fully based on gross theory of beta-decay emphasizing the special role of odd-odd FP nuclides

    Science.gov (United States)

    Yoshida, Tadashi; Tachibana, Takahiro; Chiba, Satoshi

    2017-09-01

    We applied the gross theory of β-decay to calculate the reactor antineutrino (νe) spectra emitted from 235,238U and 239,241Pu samples under neutron irradiation by summing up all the contributions from a large number of decaying fission-products (FPs). Considering the special role of the odd(Z)-odd(N) FPs in spectrum-shaping, we utilized the experimentally-known spin-parity of each odd-odd FP through the treatment proposed by Nakata, Tachibana and Yamada. Owing to this treatment, the consistency between calculated and experimental spectra was remarkably improved in a way expected from the nature of the gross theory of β-decay.

  11. Background reduction and noise discrimination in the proportional counting of tritium using pulse-shape analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hochel, R C; Hayes, D W [Du Pont de Nemours (E.I.) and Co., Aiken, S.C. (USA). Savannah River Lab.

    1975-12-01

    A pulse-shape analysis (PSA) unit of commercial design has been incorporated into a proportional counting system to determine the effectiveness of pulse-shape discrimination in increasing the sensitivity of tritium counting. It was found that a quantitative determination of tritium could be obtained directly from the PSA time spectrum eliminating the need for beta-ray energy selection used in the pulse-shape discrimination (PSD) technique. The performance of the proportional counting system was tested using the PSA unit and anticoincidence shielding, both singly and combined, under several types of background. A background reduction factor of 169 was obtained from the combined PSA-anticoincidence system with only a 2% loss in tritium counting efficiency. The PSA method was also found to offer significant reductions in noise background.

  12. Alpha/beta(gamma ray) discrimination and spillover quantification with a BaF2 scintillator

    International Nuclear Information System (INIS)

    DeVol, T.A.; Fjeld, R.A.

    1994-01-01

    A simple pulse shape discrimination technique was used to separate alpha and beta(gamma ray) interactions in a BaF 2 scintillator. The separation was not ideal, resulting in a 5.1% spillover of alpha interactions into the beta(gamma ray) channel and 11.9% spillover of beta(gamma ray) interactions into the alpha channel for a set pulse shape discriminator. The misclassification of events was reduced by post-processing the data using either a simple analytical technique or a more complex linear least squares technique. Both techniques typically reduced the difference between the expected and calculated interaction rates to <10% when the ratio of beta(gamma ray) to alpha count rate was less than 100 : 1. ((orig.))

  13. Parameter estimation of the zero inflated negative binomial beta exponential distribution

    Science.gov (United States)

    Sirichantra, Chutima; Bodhisuwan, Winai

    2017-11-01

    The zero inflated negative binomial-beta exponential (ZINB-BE) distribution is developed, it is an alternative distribution for the excessive zero counts with overdispersion. The ZINB-BE distribution is a mixture of two distributions which are Bernoulli and negative binomial-beta exponential distributions. In this work, some characteristics of the proposed distribution are presented, such as, mean and variance. The maximum likelihood estimation is applied to parameter estimation of the proposed distribution. Finally some results of Monte Carlo simulation study, it seems to have high-efficiency when the sample size is large.

  14. Electrets for beta radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    1983-01-01

    Electret dosimetry has been reviewed by Gross. A cylindrical electret ionization-chamber type dosimeter has been studied for X and gamma rays and neutrons. The principle of the dosimeter is electret charge compensation due to ionization in the chamber volume. Electret ionization chambers can be designed with one or more electrets and in various shapes. This study is concerned with a simple system, similar to a cylindrical ionization chamber (sensitive volume: 3,5 cm 3 ) using teflon electrets. Aluminum and lucite were used as wall-materials. Other experiences were performed using chambers without wall, i.e., without defined sensitive volume. The teflon electrets were obtained by Corona discharge in the gas surrounding them. The measurement of the electret charge was made by induction using a co-axial insulated metal chamber connected to an electrometer Keithley 610C. By measuring the charge before and after irradiation it is possible to obtain a calibration curve: charge (Q) versus absorbed dose (D) for the dosimeter. The irradiation setup used was the Beta Secondary Standard System of IPEN calibration laboratory with four beta sources: 90 Sr 90 Y (74 and 1850 MBq), 204 Tl (18,5 MBq) and 147 Pm (518 MBq). In some cases a 85 Kr source was also used. The electrets were tested in different radiation field geometries: electret axis parallel and perpendicular to the field. In conclusion, depending on the wall material and radiation field geometry, the teflon electret detector can be used for different dose interval determinations, using beta radiation

  15. Analytical investigation of lignite and its ash samples taken from the Afsin-Elbistan coal basin in Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Kucukonder, Adnan; Paksoy, Emine; Biber, Seyma [Kahramanmaras Suetcue Imam Univ. (Turkey). Dept. of Physics; Durdu, Burhanettin Goeker [Kilis 7 Aralik Univ., Kilis (Turkey). Opticianry Program; Baskaya, H.; Dogru, Mahmut [Bitlis Eren Univ. (Turkey). Dept. of Physics

    2014-04-15

    Lignite, taken from basin in Afsin-Elbistan region, and ash samples were analyzed according to the qualitative, quantitative and radioactivity properties. An elemental analysis was made by using the Energy Dispersive X-Ray Fluorescence (EDXRF) technique. 59.5 keV photons emitted from a {sup 241}Am source and 5.9 keV photons emitted from a {sup 55}Fe radioactive source were used for excitation. The characteristic K X-rays of the elements were counted with a Si(Li) detector. For the same samples gross alpha, gross beta and radionuclide activities were also measured. (orig.)

  16. Gross and fine motor function in fibromyalgia and chronic fatigue syndrome.

    Science.gov (United States)

    Rasouli, Omid; Fors, Egil A; Borchgrevink, Petter Chr; Öhberg, Fredrik; Stensdotter, Ann-Katrin

    2017-01-01

    This paper aimed to investigate motor proficiency in fine and gross motor function, with a focus on reaction time (RT) and movement skill, in patients with fibromyalgia (FM) and chronic fatigue syndrome (CFS) compared to healthy controls (HC). A total of 60 individuals (20 CFS, 20 FM, and 20 HC), age 19-49 years, participated in this study. Gross motor function in the lower extremity was assessed using a RT task during gait initiation in response to an auditory trigger. Fine motor function in the upper extremity was measured during a precision task (the Purdue Pegboard test) where the number of pins inserted within 30 s was counted. No significant differences were found between FM and CFS in any parameters. FM and CFS groups had significantly longer RT than HC in the gait initiation ( p =0.001, and p =0.004 respectively). In the Purdue Pegboard test, 20% in the FM group, 15% in the CFS groups, and 0% of HC group, scored below the threshold of the accepted performance. However, there were no significant differences between FM, CFS, and HC in this task ( p =0.12). Compared to controls, both CFS and FM groups displayed significantly longer RT in the gait initiation task. Generally, FM patients showed the worst results in both tests, although no group differences were found in fine motor control, according to the Purdue Pegboard test.

  17. Determination of cosmic ray produced radionuclides by means of background radiation counting system, 3

    International Nuclear Information System (INIS)

    1976-01-01

    This is the third report of the progress report series on studies of cosmic ray produced radionuclides by means of low background radiation counting system. In Part I some characteristics of a low beta-gamma coincidence spectrometer are described -- counter system, electronics, background spectra, counting efficiencies -- and studies on radioactive impurities in materials for scientific research are also described. In Part II, suitable solvents for a large scale liquid scintillation counter were examined and best combinations of solvents, solutes and naphthalene are shown. In Part III, miscellaneous topics are reported. (auth.)

  18. Evaluation of radiological impacts for environmental radioactivity distribution in the Kartini reactor area

    International Nuclear Information System (INIS)

    Yazid, M.; Suratman; Sutresna, G.; Aminjoyo, S.

    1996-01-01

    This evaluation covered of gross radioactivity. K-40 radioactivity in the water, soil and grass samples. The measurement of Cs-137 and Sr-90 radioactivity in the water samples have also been done. The aim of this research was determined of radiological impacts in the environment around the Kartini reactor. The water, soil and plant samples were counted of gross beta, Sr-90 activity by beta counter and for K-40, Cs-137 activity by low background gamma spectrometer. For this evaluation can be concluded there are no indication of the radioactivity release from the Kartini reactor operation. Gross beta radioactivity in the water, soil and grass sample are between 0.06-0.61 Bq/l, 0.24-0.79 Bq/g and 3.47-5.70 Bq/g ash. Radioactivity of K-40 in the water, soil and grass sample are between 0.09-0.56 Bq/l, 0.12-0.59 Bq/g and 0.29-0.93 Bq/g ash. The radioactivity of Cs-137 in the water samples are between under limit detectable level to 88.62 mBq/l and Sr-90 are between under limit detectable level to 24.22 mBq/l. (author)

  19. SOFT CORONAL X-RAYS FROM {beta} PICTORIS

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, H. M.; Wolk, S. J.; Drake, J. J. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Lisse, C. M. [Johns Hopkins University Applied Physics Laboratory, 11100 Johns Hopkins Road, Laurel, MD 20723 (United States); Robrade, J.; Schmitt, J. H. M. M., E-mail: hguenther@cfa.harvard.edu [Hamburger Sternwarte, Universitaet Hamburg, Gojenbergsweg 112, 21029 Hamburg (Germany)

    2012-05-01

    A-type stars are expected to be X-ray dark, yet weak emission has been detected from several objects in this class. We present new Chandra/HRC-I observations of the A5 V star {beta} Pictoris. It is clearly detected with a flux of (9 {+-} 2) Multiplication-Sign 10{sup -4} counts s{sup -1}. In comparison with previous data this constrains the emission mechanism and we find that the most likely explanation is an optically thin, collisionally dominated, thermal emission component with a temperature around 1.1 MK. We interpret this component as a very cool and dim corona, with log L{sub X} /L{sub bol} = -8.2 (0.2-2.0 keV). Thus, it seems that {beta} Pictoris shares more characteristics with cool stars than previously thought.

  20. Background reduction and noise discrimination in the proportional counting of tritium using pulse-shape analysis

    International Nuclear Information System (INIS)

    Hochel, R.C.; Hayes, D.W.

    1975-01-01

    A pulse-shape analysis (PSA) unit of commercial design has been incorporated into a proportional counting system to determine the effectiveness of pulse-shape discrimination in increasing the sensitivity of tritium counting. It was found that a quantitative determination of tritium could be obtained directly from the PSA time spectrum eliminating the need for beta-ray energy selection used in the pulse-shape discrimination (PSD) technique. The performance of the proportional counting system was tested using the PSA unit and anticoincidence shielding, both singly and combined, under several types of background. A background reduction factor of 169 was obtained from the combined PSA-anticoincidence system with only a 2% loss in tritium counting efficiency. The PSA method was also found to offer significant reductions in noise background. (Auth.)

  1. The liquid scintillation counting efficiency for 137mCs+137mBa and ''129 I; 'Eficiencias de recuento por centelleo liquido para el Cs+13 mBa y ''129 I

    Energy Technology Data Exchange (ETDEWEB)

    Grau CarLes, A.; Grau Malonda, A.

    1995-07-01

    We compute the liquid scintillation counting efficiency for 137Cs+137mBa and ''129 I taking into account the scintillator chemical composition. We consider the beta transition shape factors for the for bidden beta transitions of these nuclides, and the effects of 137mBa and 129mXe half-lives on the total counting efficiency. (Author) 8 refs.

  2. Optimization of Plastic Scintillator Thicknesses for Online Beta Detection in Mixed Fields

    Energy Technology Data Exchange (ETDEWEB)

    Pourtangestani, K.; Machrafi, R. [University of Ontario Institute of Technology, Oshawa, ON (Canada)

    2013-07-15

    For efficient beta detection in a mixed beta-gamma field, Monte Carlo simulation models have been developed to optimize the thickness of a plastic scintillator used in whole body monitor. The simulation has been performed using MCNP/X code and different thicknesses of plastic scintillators ranging from 150 to 600 {mu}m have been used. The relationship between the thickness of the scintillator and the efficiency of the detector has been analysed. For 150 {mu}m thickness, an experimental investigation has been conducted with different beta sources at different positions on the scintillator and the counting efficiency of the unit has been measured. Evaluated data along with experimental ones have been discussed. A thickness of 300 {mu}m to 500 {mu}m has been found to be an optimum thickness for better beta detection efficiency in the presence of low energy gamma ray. (author)

  3. Validating the Rett Syndrome Gross Motor Scale.

    Science.gov (United States)

    Downs, Jenny; Stahlhut, Michelle; Wong, Kingsley; Syhler, Birgit; Bisgaard, Anne-Marie; Jacoby, Peter; Leonard, Helen

    2016-01-01

    Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age and genotype were investigated. Clinical assessment scores for 38 girls and women with Rett syndrome who attended the Danish Center for Rett Syndrome were used to assess consistency of measurement. Principal components analysis enabled the calculation of three factor scores: Sitting, Standing and Walking, and Challenge. Motor scores were poorer with increasing age and those with the p.Arg133Cys, p.Arg294* or p.Arg306Cys mutation achieved higher scores than those with a large deletion. The repeatability of clinical assessment was excellent (intraclass correlation coefficient for total score 0.99, 95% CI 0.93-0.98). The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice and clinical trials.

  4. Kajian Empiris Variabel Makroekonomi Dan Mikroekonomi Terhadap Beta Saham Pada Perusahaan Yang Terdaftar Di Kompas 100 Periode 2009-2013

    Directory of Open Access Journals (Sweden)

    Carrolina Caecilia

    2014-10-01

    Full Text Available This study analizes about the influence of macroeconomics and microeconomics variables towards stock of beta. The macroeconomics variables tested are inflation, interest rate, middle rate, gross domestic product, and money supply, while the microeconomics are asset growth, current ratio, debt to equity ratio, return on equity, and dividend payout ratio. The results are that out of 10 macroeconomics and microeconomics variables tested, only 8 passed the classical assumption test. Simultaneously (F test, 8 variables that passed affects stock of beta simultaneously. Partially (t test, only interest rate and current ratio has a positive significant effect.

  5. Counting efficiency for liquid scintillator systems with a single multiplier phototube; Eficiencia de recuento en espectrometros de centelleo con un solo fotomultiplicador

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Garcia-Torano, E

    1984-07-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs.

  6. On-line plutonium measurement by alpha counting using a silica glass sensor

    International Nuclear Information System (INIS)

    Edeline, J.C.; Furgolle, B.

    1980-01-01

    Some cerium activated high purity silica glasses are good sensors for ionising particles counting. These sensors may be used for measuring plutonium concentrations in corrosive solutions which are typical in reprocessing operations. The thickness of the sensor has been reduced to minimize beta sensitivity. The thin sensor is hold by molecular adhesion to a thick glass mount which is soldered to the stainless steel sample cell [fr

  7. Quantum Gross-Pitaevskii Equation

    Directory of Open Access Journals (Sweden)

    Jutho Haegeman, Damian Draxler, Vid Stojevic, J. Ignacio Cirac, Tobias J. Osborne, Frank Verstraete

    2017-07-01

    Full Text Available We introduce a non-commutative generalization of the Gross-Pitaevskii equation for one-dimensional quantum gasses and quantum liquids. This generalization is obtained by applying the time-dependent variational principle to the variational manifold of continuous matrix product states. This allows for a full quantum description of many body system ---including entanglement and correlations--- and thus extends significantly beyond the usual mean-field description of the Gross-Pitaevskii equation, which is known to fail for (quasi one-dimensional systems. By linearizing around a stationary solution, we furthermore derive an associated generalization of the Bogoliubov -- de Gennes equations. This framework is applied to compute the steady state response amplitude to a periodic perturbation of the potential.

  8. Relation between the 2{nu}{beta}{beta} and 0{nu}{beta}{beta} nuclear matrix elements

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, Petr [Kellogg Radiation Laboratory, Caltech, Pasadena, CA 91125 (United States); Simkovic, Fedor [Department of Nuclear Physics and Biophysics, Comenius University, Mlynska dolina F1, SK-84248 Bratislava (Slovakia)

    2011-12-16

    A formal relation between the GT part of the nuclear matrix elements M{sub GT}{sup 0{nu}} of 0{nu}{beta}{beta} decay and the closure matrix elements M{sub cl}{sup 2{nu}} of 2{nu}{beta}{beta} decay is established. This relation is based on the integral representation of these quantities in terms of their dependence on the distance r between the two nucleons undergoing transformation. We also discuss the difficulties in determining the correct values of the closure 2{nu}{beta}{beta} decay matrix elements.

  9. Field transportable beta spectrometer. Innovative technology summary report

    International Nuclear Information System (INIS)

    1998-12-01

    The objective of the Large-Scale Demonstration Project (LSDP) is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Test Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved deactivation and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies. One such capability being addressed by the D and D Focus Area is rapid characterization for facility contaminants. The technology was field demonstrated during the period January 7 through January 9, 1997, and offers several potential benefits, including faster turn-around time, cost reduction, and reduction in secondary waste. This report describes a PC controlled, field-transportable beta counter-spectrometer which uses solid scintillation coincident counting and low-noise photomultiplier tubes to count element-selective filters and other solid media. The dry scintillation counter used in combination with an element-selective technology eliminates the mess and disposal costs of liquid scintillation cocktails. Software in the instrument provides real-time spectral analysis. The instrument can detect and measure Tc-99, Sr-90, and other beta emitters reaching detection limits in the 20 pCi range (with shielding). Full analysis can be achieved in 30 minutes. The potential advantages of a field-portable beta counter-spectrometer include the savings gained from field generated results. The basis for decision-making is provided with a rapid turnaround analysis in the field. This technology would be competitive with the radiometric analysis done in fixed laboratories and the associated chain of custody operations

  10. Measurement of radioactivity in water samples

    International Nuclear Information System (INIS)

    Richards, L.

    1990-01-01

    Public concern about the levels of radioactivity release to the environment whether authorised discharges or resulting from nuclear accident, has increased in recent years. Consequently there is increasing pressure for reliable data on the distribution of radioactivity and the extent of its intrusion into food chains and water supplies. As a result a number of laboratories not experienced in radioactivity measurements have acquired nucleonic counting equipment. These notes explore the underlying basics and indicate sources of essential data and information which are required for a better understanding of radioactivity measurements. Particular attention is directed to the screening tests which are usually designated ''gross'' alpha and ''gross'' beta activity measurement. (author)

  11. Gross motor skill development of kindergarten children in Japan.

    Science.gov (United States)

    Aye, Thanda; Kuramoto-Ahuja, Tsugumi; Sato, Tamae; Sadakiyo, Kaori; Watanabe, Miyoko; Maruyama, Hitoshi

    2018-05-01

    [Purpose] The purposes of this study were to assess and explore the gender-based differences in gross motor skill development of 5-year-old Japanese children. [Subjects and Methods] This cross-sectional study recruited 60 healthy 5-year-old (third-year kindergarten, i.e., nencho ) children (34 boys, 26 girls) from one local private kindergarten school in Otawara city, Tochigi Prefecture, Japan. Gross motor skills, including six locomotor and six object control skills, were assessed using the test of gross motor development, second edition (TGMD-2). All subjects performed two trials of each gross motor skill, and the performances were video-recorded and scored. Assessment procedures were performed according to the standardized guidelines of the TGMD-2. [Results] The majority of subjects had an average level of overall gross motor skills. Girls had significantly better locomotor skills. Boys had significantly better object control skills. [Conclusion] The gross motor skill development of 5-year-old Japanese children involves gender-based differences in locomotor and object control skills. This study provided valuable information that can be used to establish normative references for the gross motor skills of 5-year-old Japanese children.

  12. Validating the Rett Syndrome Gross Motor Scale.

    Directory of Open Access Journals (Sweden)

    Jenny Downs

    Full Text Available Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age and genotype were investigated. Clinical assessment scores for 38 girls and women with Rett syndrome who attended the Danish Center for Rett Syndrome were used to assess consistency of measurement. Principal components analysis enabled the calculation of three factor scores: Sitting, Standing and Walking, and Challenge. Motor scores were poorer with increasing age and those with the p.Arg133Cys, p.Arg294* or p.Arg306Cys mutation achieved higher scores than those with a large deletion. The repeatability of clinical assessment was excellent (intraclass correlation coefficient for total score 0.99, 95% CI 0.93-0.98. The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice and clinical trials.

  13. Measurement of radionuclides using ion chromatography and flow-cell scintillation counting with pulse shape discrimination

    International Nuclear Information System (INIS)

    DeVol, T.A.; Fjeld, R.A.

    1995-01-01

    A project has been initiated at Clemson Univ. to develop a HPLC/flow- cell system for analysis of non-gamma emitting radionuclides in environmental samples; an important component is development of a low background flow-cell detector that counts alpha and beta particles separately through pulse shape discrimination. Objective of the work presented here is to provide preliminary results of an evaluation of the following scintillators: CaF 2 :Eu, scintillating glass, and BaF 2 . Slightly acidic aqueous solutions of the alpha emitter 233 U and the beta emitter 45 Ca were used. Detection efficiencies and minimum detectable activities were determined

  14. The Gross-Llewellyn Smith sum rule

    International Nuclear Information System (INIS)

    Scott, W.G.

    1981-01-01

    We present the most recent data on the Gross-Llewellyn Smith sum rule obtained from the combined BEBC Narrow Band Neon and GGM-PS Freon neutrino/antineutrino experiments. The data for the Gross-Llewellyn Smith sum rule as a function of q 2 suggest a smaller value for the QCD coupling constant parameter Λ than is obtained from the analysis of the higher moments. (author)

  15. 75 FR 78897 - Definition of Omission From Gross Income

    Science.gov (United States)

    2010-12-17

    ... Definition of Omission From Gross Income AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Final regulations. SUMMARY: This document contains final regulations defining an omission from gross income for... overstatement of basis in a sold asset results in an omission from gross income. The regulations will affect any...

  16. Determination of plutonium-241 by liquid scintillation counting method and its application to environmental samples

    International Nuclear Information System (INIS)

    Watanabe, Miki; Amano, Hikaru

    1997-03-01

    Radionuclides are usually measured by gross counting mode in liquid scintillator counting (LSC) which measures both α and β pulses. This method can easily measure radioactivities, but its background counting is high. Recently reported α-β pulse shape discrimination method (α-β PSD method) in LSC which distinguishes α pulses from β pulses, shows low background counting, so it makes the detection limit lower. The aim of this research is to develop the best method for the determination of 241 Pu which is β-emitter, and Pu isotopes of α-emitters which have long half-lives and stay long in animal body. In this research, two LSC machines was carried out in different scintillators, vial volumes, measurement modes and so on. The following things were found. 1. The liquid scintillator based on naphthalene is proved to be the best separator of α-ray from β-ray, because it acts quickly in energy translation procedure between solvent and aromatic compounds. 2. α-β PSD method makes the background counting rate ten times lower than usual method. It makes the measurement performance better. 3. It is possible to determine 241 Pu in environmental samples around Chernobyl by the combination of LSC and radiochemical separation methods. (author)

  17. Haematological and genetic features of delta beta-thalassaemia in Pakistan

    International Nuclear Information System (INIS)

    Ahmad, S.; Anwar, M.

    2006-01-01

    Objective: To describe the hematological and genetic features of delta beta-thalassaemia in Pakistani patients. Design: Descriptive case series. Place and Duration of Study: Department of Pathology, PNS Shifa, Karachi and Department of Hematology, Armed Forces Institute of Pathology, Rawalpindi, from January 1994 to April 2004. Patients and Methods: Thirteen individuals from six unrelated Pakistani families with a hematological diagnosis of delta beta-thalassaemia were studied. A brief clinical history, and the results of blood counts, absolute values, Hb-F, Hb-A/sub 2/, and hemoglobin electrophoresis were recorded. The DNA from each subject was first screened for the delta beta-thalassaemia mutations found in the Pakistani population. The samples were then screened for the Invl Del sup G/gamma(sup A/gamma delta beta). Results: The subjects included six heterozygote, six homozygotes and one compound heterozygote of delta beta and delta beta-thalassaemia. All heterozygote and 4/6 homozygotes were asymptomatic. One homo zygote had thalassaemia intermedia while another had transfusion dependent anemia. The mean Hb, TRBC, MCV, MCH, Hb-F and Hb-A/sub 2/ in delta beta-thalassaemia heterozygote were 11.6 g/dl, 5.37 x 1012/L, 70.9 fl, and 21.7 pg, 14% and 2.6% respectively. The same values in the four un transfused homo zygote were 10.6 g/dl, 5.34x1012/L, 69.211, and 20.8pg, 100% and 0% respectively. The mutation analysis revealed that all 13 individuals had the same Invl Del sup G/gamma(sup A/gamma delta beta). Conclusion: delta beta-thalassaemia is a rare disorder in Pakistan. Although the clinical picture is very mild its combination with delta beta-thalassaemia trait can produce a sever transfusion dependent thalassaemia. The DNA based diagnosis is possible in the prenatal as well as the postnatal period. (author)

  18. Alternative Measure of Wellbeing: Bhutan's Gross National ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    There is growing demand for innovative yet rigorous measures of national wellbeing beyond gross domestic product. In 2008, the Centre for Bhutan Studies - Bhutan's main policy research centre - posted data from a preliminary survey of the country's Gross National Happiness (GNH). The Centre for Bhutan Studies ...

  19. 7 CFR 1424.7 - Gross payable units.

    Science.gov (United States)

    2010-01-01

    ... payments (APP), and base production payments (BPP). Repayment rates shall be based on previous payment... 50 gallons of net production increase. (2) For BPP, which will be made on production not eligible for... biodiesel production gross payable units. (3) Adding the APP and BPP to determine biodiesel gross payable...

  20. [Hans Gross as an archaeologist--the significance of archaeology for 'encyclopedic' criminology].

    Science.gov (United States)

    Karl, Stephan; Bachhiesl, Christian

    2014-01-01

    In some cases, forensics and criminology have to cooperate with disciplines that usually are counted among the humanities, e.g. with archaeology. This article examines the significance of this cooperation for the criminological epistemology at the turn of the 19th century. These methodological considerations are illustrated by an example: When Hans Gross, who became the founder of the Austrian School of Criminology later, saw an unusually shaped hill near Feldbach, a town in southern Styria, he assumed this hill to be a burial mound and informed the responsible archaeological authorities immediately. Further investigations showed, however, that this hill was a natural formation. This is an early example for interdisciplinary cooperation, which proves that both in archaeology and in criminology a thorough inspection of the site is decisive for further scientific analysis of the topic of research.

  1. Gross Sales Tax Collections

    Data.gov (United States)

    City of Jackson, Mississippi — This data is captured directly from the MS Department of Revenue and specific to the City of Jackson. It is compiled from Gross Sales Tax reported by taxpayers each...

  2. Loovkirjutamist õpetab Philip Gross

    Index Scriptorium Estoniae

    2011-01-01

    T.S. Elioti luulepreemia laureaat Philip Gross on Tallinna Ülikooli talvekooli rahvusvahelise kursuse "Poetry: A Conversation between Words and Silence" läbiviija. Oma seminarides keskendub ta lisaks loovkirjutamisele ka loova lugemise vajadusele

  3. A 4{pi} Anticoincidence Arrangement for Measurements of Beta-Ray Emitting Isotopes; Montage a Anticoiencidence 4{pi} pour la Mesure des Radioisotopes Emetteurs Beta; 4{pi} sistema schetchikov antisovpadenij dlya izmerenij beta-izluchayushchikh izotopov; Aparato de Recuento 4{pi} en Anticoincidencia para Medir Emisores Beta

    Energy Technology Data Exchange (ETDEWEB)

    Srdoc, D. [Institute ' ' Ruder Boskovic' ' , Zagreb, Yugoslavia (Croatia)

    1965-10-15

    A 4{pi} anticoincidence, low-background counting system consisting of two specially designed parallel plate counters and a bridge anticoincidence circuit is described. Each counter is of a flat, mica window ''pancake'' type. The diameter of the counters is much larger than the gap between the plates. Good counting properties are obtained in spite of the unusual counter geometry, owing to the flexibility of the counter shape design when a neon-halogen mixture is used. The counters are so arranged that both windows face the sample, leaving a narrow slit for the sample holder. The sample is spread on a thin metalized plastic film. The pulses from both counters due to beta-particles coming from the sample are recorded, giving a 4{pi} counting geometry. The pulses due to cosmic particles triggering both counters simultaneously cancel out in a simple bridge anticoincidence arrangement, thus eliminating the need for an electronic circuit. Furthermore, the parallel plate counters used here for beta-particle counting possess a markedly reduced sensitivity to gamma-rays near the threshold voltage, resulting in a further lowering of the background. Sources of beta-particles of higher energies, as well as gamma-ray sources, can also be measured by the described system, because in the proposed geometry there is no possibility of triggering both counters simultaneously, as is the case with the conventional guard-counter arrangements. (author) [French] Le memoire decrit un ensemble de mesure a anticolhcidence 4{pi}, ayant un faible bruit de fond, compose de deux compteurs speciaux a plateaux paralleles relies par un pont d'anticofncidence. Ces deux compteurs sont de type circulaire plat a fenetre de mica. Le diametre du compteur est tres superieur a l'espace entre les plaques. Malgre sa geometrie inusitee, l'appareil a des proprietes de comptage satisfaisantes en raison de la souplesse que lui conferent ses caracteristiques lorsqu'on utilise un melange halogene-neon. Les

  4. Low-level multicounter {beta}/{gamma} systems with external guards in surface and shallow underground laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Theodorsson, P [Iceland Univ. (Iceland). Science Inst.

    1997-03-01

    When weak samples are measured it is important that they can be given ample counting time in order to obtain satisfactory accuracy and that the background count rate can be checked well. This calls for a high counting capacity, which multidetectors can bring us. I will discuss development possibilities of low-level {beta}/{gamma} multidetector systems with an external anticosmic shield that will in many cases be operated in underground laboratories. These simple and low-cost system can frequently help us in increasing the number of detectors. Three concepts are combined in these systems: (1) multidetectors, (2) an external anticosmic (or guard) detector arrangement and (3) overburden shielding. (orig.)

  5. Low-dimensional chiral physics. Gross-Neveu universality and magnetic catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, Daniel David

    2012-09-27

    beyond the determination of critical exponents, we analyze the Gross-Neveu beta functions at finite temperature. The critical temperature for the 2nd order phase transition within the 2d-Ising universality class is determined as a function of the number of fermion species and we try to quantitatively describe the suppression of the so-called Ginzburg region with the number of fermion flavors. Finally we analyze the minimal coupling of the fermionic degrees of freedom to a background magnetic field that leads to the phenomenon of magnetic catalysis. The external magnetic field modifies the mode structure of the free theory to relativistic Landau levels, enhancing the efficiency of quantum fluctuations by dimensional reduction, thus leading to spontaneous symmetry breaking even for subcritical values of the coupling. We identify the corresponding renormalization group mechanism and quantitatively study the magnetic field dependence of the dynamically generated spectral gap.

  6. Low-dimensional chiral physics. Gross-Neveu universality and magnetic catalysis

    International Nuclear Information System (INIS)

    Scherer, Daniel David

    2012-01-01

    of critical exponents, we analyze the Gross-Neveu beta functions at finite temperature. The critical temperature for the 2nd order phase transition within the 2d-Ising universality class is determined as a function of the number of fermion species and we try to quantitatively describe the suppression of the so-called Ginzburg region with the number of fermion flavors. Finally we analyze the minimal coupling of the fermionic degrees of freedom to a background magnetic field that leads to the phenomenon of magnetic catalysis. The external magnetic field modifies the mode structure of the free theory to relativistic Landau levels, enhancing the efficiency of quantum fluctuations by dimensional reduction, thus leading to spontaneous symmetry breaking even for subcritical values of the coupling. We identify the corresponding renormalization group mechanism and quantitatively study the magnetic field dependence of the dynamically generated spectral gap.

  7. Renal tubular dysfunction nephrocalcinosis in a patient with BetaThalassemia Minor

    International Nuclear Information System (INIS)

    Prabahar, M.R.; Jain, M.; Chandrasekaran, V.; Indumathi, E.; Soundrarajan, P.

    2008-01-01

    Thalassemia is a hereditary anemia resulting from defect in hemoglobinproduction. Beta thalassemia is due to impaired production. Beta thalassemiais due to impaired production of beta globin chains, leading to a relativeexcess of alpha globin chains. The term beta thalassemia minor is used todescribe heterozygotes, who carry one normal beta globin and one betathalassemic allele. The vast majority of these patients are asymptomatic.However, a variety of renal tubular abnormalities including hypercaliuria,hypomagnesemia with renal magnesium wasting, decreased tubular absorption ofphosphorous, hypouricemia with renal uric acid wasting, renal glycosuria andtubular proteinuria have been described even in patients with betathalassemia minor. We here in report a 24-year old patient who was found tohave thalassemia minor and nephrocalcinosis with evidence of renal tubulardysfunction. Investigations revealed normal renal function, hypercalciuria,reduced tubular reabsorption of phosphorous, hypomagnesemia and renalmagnesium wasting. Screening for aminoaciduria was found to be negative. Anacid loading test revealed normal urinary acidification. Ultrasonogram of theabdomen revealed nephrocalcinosis and splenomegaly. Detailed work up foranemia showed normal white cell and platelet count while peripheral smearshowed microcytic hypochromic anemia with few target cells. Hemoglobinelectrophoresis revealed hemoglobin A of 92%, hemoglobin A2 of 6.2% andhemoglobin F of 1.8% consistent with beta thalassemia minor. Her parentalscreening was normal. A diagnosis of beta thalassemia minor with renaltubular dysfunction was made and the patient was started on thiazidediuretics to reduce hypercalciuria and advised regular follow-up. (author)

  8. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  9. 26 CFR 1.832-1 - Gross income.

    Science.gov (United States)

    2010-04-01

    ..., except that in the case of a mutual fire insurance company described in § 1.831-1 the amount of single... TAXES Other Insurance Companies § 1.832-1 Gross income. (a) Gross income as defined in section 832(b)(1... approved by the National Convention of Insurance Commissioners, as well as the gain derived from the sale...

  10. The MAJORANA DEMONSTRATOR: A Search for Neutrinoless Double-beta Decay of Germanium-76

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, Alexis G.; Aguayo, Estanislao; Avignone, F. T.; Zhang, C.; Back, Henning O.; Barabash, Alexander S.; Bergevin, M.; Bertrand, F.; Boswell, M.; Brudanin, V.; Busch, Matthew; Chan, Yuen-Dat; Christofferson, Cabot-Ann; Collar, J. I.; Combs, Dustin C.; Cooper, R. J.; Detwiler, Jason A.; Leon, Jonathan D.; Doe, Peter J.; Efremenko, Yuri; Egorov, Viatcheslav; Ejiri, H.; Elliott, S. R.; Esterline, James H.; Fast, James E.; Fields, N.; Finnerty, P.; Fraenkle, Florian; Gehman, Victor M.; Giovanetti, G. K.; Green, M.; Guiseppe, Vincente; Gusey, K.; Hallin, A. L.; Hazama, R.; Henning, Reyco; Hime, Andrew; Hoppe, Eric W.; Horton, Mark; Howard, Stanley; Howe, Mark; Johnson, R. A.; Keeter, K.; Keillor, Martin E.; Keller, C.; Kephart, Jeremy D.; Kidd, M. F.; Knecht, A.; Kochetov, Oleg; Konovalov, S.; Kouzes, Richard T.; LaFerriere, Brian D.; LaRoque, B. H.; Leviner, L.; Loach, J. C.; MacMullin, S.; Marino, Michael G.; Martin, R. D.; Mei, Dong-Ming; Merriman, Jason H.; Miller, M. L.; Mizouni, Leila; Nomachi, Masaharu; Orrell, John L.; Overman, Nicole R.; Phillips, D.; Poon, Alan; Perumpilly, Gopakumar; Prior, Gersende; Radford, D. C.; Rielage, Keith; Robertson, R. G. H.; Ronquest, M. C.; Shima, T.; Shirchenko, M.; Snavely, Kyle J.; Sobolev, V.; Steele, David; Strain, J.; Thomas, K.; Timkin, V.; Tornow, Werner; Vanyushin, I.; Varner, R. L.; Vetter, Kai; Vorren, Kris R.; Wilkerson, J. F.; Wolfe, B. A.; Yakushev, E.; Young, A.; Yu, Chang-Hong; Yumatov, Vladimir

    2012-09-28

    The observation of neutrinoless double-beta decay would determine whether the neutrino is a Majorana particle and provide information on the absolute scale of neutrino mass. The MAJORANA Collaboration is constructing the DEMONSTRATOR, an array of germanium detectors, to search for neutrinoless double-beta decay of 76Ge. The DEMONSTRATOR will contain 40 kg of germanium; up to 30 kg will be enriched to 86% in 76Ge. The DEMONSTRATOR will be deployed deep underground in an ultra-low-background shielded environment. Operation of the DEMONSTRATOR aims to determine whether a future tonne-scale germanium experiment can achieve a background goal of one count per tonne-year in a 4-keV region of interest around the 76Ge neutrinoless double-beta decay Q-value of 2039 keV.

  11. An automatic counting and recording system (1963); Ensemble de comptage a enregistrement automatique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Pierre, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-09-15

    An automatic control, counting and programing system for the collection of single crystal diffractometry data was designed by the author for a neutron diffractometer in 1958 at C.E.N - Grenoble. A part of the whole instrument, 'The Automatic Counting and Recording System', is described in this paper. Its applications are numerous and extensive, e.g.: the system has been designed for neutron diffractometer, but it can easily be adapted either for use with X-rays or measurement of mean life in {beta} decay analysis. (author) [French] Un ensemble automatique de telecommande, comptage et programmation pour la diffractometrie a cristal unique a ete etudie et realise par l'auteur pour la diffraction des neutrons en 1958 au C.E.N - Grenoble. Le present rapport decrit a ''l'Ensemble de Comptage a Enregistrement Automatique'' qui est une partie de l'appareillage complet. Ses applications sont nombreuses et peuvent s'etendre a de nouveaux domaines. En effet cet ensemble qui a ete etudie pour fonctionner avec un diffractometre a neutron, peut facilement s'adapter a la technique de diffraction des rayons X ou par exemple a celle de decroisasnce d'activite {beta}. (auteur)

  12. Effect of temperate climate tree species on gross ammonification, gross nitrification and N2O formation

    Science.gov (United States)

    Brüggemann, N.; Rosenkranz, P.; Papen, H.; Butterbach-Bahl, K.

    2003-04-01

    Microbial nitrogen turnover processes in the soil, like ammonification, nitrification and denitrification, play an important role in the formation of nitrous oxide (N2O): (i) ammonification, because it releases nitrogen from organic material in the form of ammonium (NH4+), which in turn can serve as substrate for nitrification; (ii) nitrification itself (i.e. the turnover of NH4+ to nitrate, NO3-), during which nitric oxide (NO) and N2O can be released as by-products at varying ratios; (iii) denitrification, in which NO3- serves as electron acceptor and is converted to molecular nitrogen (N2) via NO and N2O as intermediates, that can also be partially lost to the atmosphere. Temperate forest soils are a substantial source of atmospheric N2O contributing up to 10% to the total atmospheric N2O budget. However, this figure is afflicted with a huge uncertainty due to a number of factors governing the soil N2O formation, consumption, release and uptake, which are not fully understood at present. To one of these factors belongs the influence of the tree species on nitrogen turnover processes in the soil and the formation of N trace gases related with them. The aim of the present work was to analyse this tree species effect for the temperate climate region. For this purpose the effect of five different temperate tree species, having the same age and growing on the same soil in direct vicinity to each other, on gross ammonification and gross nitrification as well as on N2O formation was investigated. The trees (common beech, Fagus sylvatica; pedunculate oak, Quercus robur; Norway spruce, Picea abies; Japanese larch, Larix leptolepis; mountain pine, Pinus mugo) were part of a species trial in Western Jutland, Denmark, established in 1965 on a former sandy heathland. Samples from the soil under these five tree species were taken in spring and in summer 2002, respectively, differentiating between organic layer and mineral soil. The gross rates of ammonification as well of

  13. Water chemical control of the TRIGA IPR-R1 reactor primary cooling system

    International Nuclear Information System (INIS)

    Auler, Lucia M.L.A; Chaves, Renata D.A.; Palmieri, Helena E.L.; Menezes, Maria Angela de B.C.; Oliveira, Paulo F.; Kastner, Geraldo F.; Damazio, Ilza; Fagundes, Oliene dos R.; Cintra, Maria Olivia C.; Andrade, Geraldo V. de; Amaral, Angela M.; Franco, Milton B.; Fortes, Flavio; Gomes, Nilton Carlos; Vidal, Andrea; Maretti Junior, Fausto; Knupp, Eliana A.N.; Souza, Wagner de; Guedes, Joao B.; Furtado, Renato C.S.

    2013-01-01

    The TRIGA Mark I IPR-R1 reactor located at CDTN/CNEN has been in operation and contributed to research and with services to society since 1960. Is has been used in several activities such as nuclear power plant operation, graduate and post-graduate training courses, isotope production, and as an analytical irradiation tool of different types of samples. Among the several structural and operational safety requirements is the chemical quality control of the primary circuit cooling water. The aim of this work was to check the cooling water quality from the pool reactor. A water sampling plan was proposed (May, 2011 - June, 2012) and presents the results obtained in this period. The natural radioactivity level as gross alpha and gross beta activity and other chemical parameters (pH and electric conductivity) of the samples were analyzed. Some instrumental techniques were used: potentiometric methods (pH), conductometric methods (electrical conductivity, EC) and gross α and gross β proportional counting system). (author)

  14. 26 CFR 1.61-3 - Gross income derived from business.

    Science.gov (United States)

    2010-04-01

    ... Section 1.61-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Definition of Gross Income, Adjusted Gross Income, and..., merchandising, or mining business, “gross income” means the total sales, less the cost of goods sold, plus any...

  15. Predictors of change in CD4 lymphocyte count and weight among HIV infected patients on anti-retroviral treatment in Ethiopia: a retrospective longitudinal study.

    Directory of Open Access Journals (Sweden)

    Ayalu A Reda

    Full Text Available Antiretroviral treatment (ART has been introduced in Ethiopia a decade ago and continues to be scaled up. However, there is dearth of literature on the impact of ART on changes in CD4 lymphocyte count and weight among patients on treatment.To determine the predictors of change in CD4 lymphocyte count and weight among HIV/AIDS infected patients taking antiretroviral treatment in eastern Ethiopia.A retrospective cohort study was conducted among HIV/AIDS patients taking ART from 2005 to 2010. A sample of 1540 HIV infected adult patients who started antiretroviral therapy in hospitals located in eastern Ethiopia were included in the study. The primary outcomes of interest were changes in CD4 count and weight. Descriptive statistics and multivariable regression analyses were performed to examine the outcomes among the cohort.Both the median CD4 lymphocyte counts and weight showed improvements in the follow up periods. The multivariate analysis shows that the duration of ART was an important predictor of improvements in CD4 lymphocyte count (beta 7.91; 95% CI 7.48-8.34; p 0.000 and weight (beta 0.15; 95% CI 0.13-0.18; p 0.000. Advanced WHO clinical stage, lower baseline CD4 cell count, and baseline hemoglobin levels were factors associated with decline in weight. Actively working patients had higher CD4 lymphocyte count and weight compared to those that were ambulatory (p<0.05.We detected a substantial increment in weight and CD4 lymphocyte count among the patients who were taking ART in eastern Ethiopia. Patients who are of older age, with low initial CD4 lymphocyte count, late stage of the WHO clinical stages and lower hemoglobin level may need special attention. The reasons for the improved findings on CD4 count and weight throughout the five years of follow up merit further investigation.

  16. BETA digital beta radiometer

    International Nuclear Information System (INIS)

    Borovikov, N.V.; Kosinov, G.A.; Fedorov, Yu.N.

    1989-01-01

    Portable transportable digital beta radiometer providing for measuring beta-decay radionuclide specific activity in the range from 5x10 -9 up to 10 -6 Cu/kg (Cu/l) with error of ±25% is designed and introduced into commercial production for determination of volume and specific water and food radioactivity. The device specifications are given. Experience in the BETA radiometer application under conditions of the Chernobyl' NPP 30-km zone has shown that it is convenient for measuring specific activity of the order of 10 -8 Cu/kg, and application of a set of different beta detectors gives an opportunity to use it for surface contamination measurement in wide range of the measured value

  17. A beta skin dose monitor using an Eberline RO-2 ion chamber

    International Nuclear Information System (INIS)

    Jester, W.A.; Levine, S.H.; Lin, T.J.; Hock, R.

    1994-01-01

    The authors have developed a portable beta skin dose monitor that uses an Eberline RO-2trademark ion chamber. The development was based, in part, upon the previous development of a beta skin dose monitor employing silicon detectors. In this current work, the two entrance windows of the RO-2 were replaced by windows having a total mass thickness of 1.74 mg/cm 2 . A two section source-detector holder was constructed. One section fastens to the RO-2 and holds the detector at the right position to determine the contact skin dose from beta emitters located on surfaces. A second section attaches to the first, and provides fixed counting geometry for radioactive samples such as hot particles. The first section also contains a slide mechanism that allows the placement of absorbers of zero (0), 8.38, and 1000 mg/cm 2 between the detector window and the beta source. The detector response to these absorbers allows for the determination of beta skin dose. The system was modeled using a Monte Carlo beta attenuation code computing the beta skin dose to RO-2 detector response as a function of absorber thickness, average beta energy, source diameter and source position. Using the RO-2 reading from each of the three absorber configurations allows the calculation of beta skin dose and the average beta energy. The results of these calculations were confirmed through the use of three massless radioactive beta sources, traceable to the National Institute of Standards and Technology, and several utility-supplied hot particles having well-established contact skin doses. An extrapolation chamber was also used to confirm the results obtained from this monitor. This system is now use at the Pennsylvania Power and Light (PP and L) Company, the project sponsor. ((orig.))

  18. LHCb: $2\\beta_s$ measurement at LHCb

    CERN Multimedia

    Conti, G

    2009-01-01

    A measurement of $2\\beta_s$, the phase of the $B_s-\\bar{B_s}$ oscillation amplitude with respect to that of the ${\\rm b} \\rightarrow {\\rm c^{+}}{\\rm W^{-}}$ tree decay amplitude, is one of the key goals of the LHCb experiment with first data. In the Standard Model (SM), $2\\beta_s$ is predicted to be $0.0360^{+0.0020}_{-0.0016} \\rm rad$. The current constraints from the Tevatron are: $2\\beta_{s}\\in[0.32 ; 2.82]$ at 68$\\%$CL from the CDF experiment and $2\\beta_{s}=0.57^{+0.24}_{-0.30}$ from the D$\\oslash$ experiment. Although the statistical uncertainties are large, these results hint at the possible contribution of New Physics in the $B_s-\\bar{B_s}$ box diagram. After one year of data taking at LHCb at an average luminosity of $\\mathcal{L}\\sim2\\cdot10^{32}\\rm cm^{-2} \\rm s^{-1}$ (integrated luminosity $\\mathcal{L}_{\\rm int}\\sim 2 \\rm fb^{-1}$), the expected statistical uncertainty on the measurement is $\\sigma(2\\beta_s)\\simeq 0.03$. This uncertainty is similar to the $2\\beta_s$ value predicted by the SM.

  19. Determination of Li, B, and F by rapid instrumental neutron activation analysis using beta-particle counting

    International Nuclear Information System (INIS)

    Schmidt, J.O.; Palgaard, L.; Gwozdz, R.; Belhage, L.O.

    1984-01-01

    For the simultaneous determination of Li, B, and F, the application of rapid instrument neutron activation analysis was studied using 1.5s of irradiation and β-particle counting of 8 Li, 12 B, and 20 F. The fast transfer facility, Mach-1, the counting equipment, a 4-channel multiplexer, and a time-base controller are discussed. Further, the technique of simultaneous decay curve analysis of three successive decays is presented and quality control by residual analysis is demonstrated. Finally, analytical results are presented of the NBS-environmental standards Coal-1632a and Coal-1635, and of three BCR-coals intended as references materials

  20. National pattern for the realization of the unit of the dose speed absorbed in air for beta radiation. (Method: Ionometer, cavity of Bragg-Gray implemented in an extrapolation chamber with electrodes of variable separation, exposed to a field of beta radiation of 90Sr/90Y)

    International Nuclear Information System (INIS)

    Alvarez R, M. T.; Morales P, J. R.

    2001-01-01

    From the year of 1987 the Department of Metrology of the ININ, in their Secondary Laboratory of Calibration Dosimetric, has a patron group of sources of radiation beta and an extrapolation chamber of electrodes of variable separation.Their objective is to carry out of the unit of the dose speed absorbed in air for radiation beta. It uses the ionometric method, cavity Bragg-Gray in the extrapolation chamber with which it counts. The services that offers are: i) it Calibration : Radioactive Fuentes of radiation beta, isotopes: 90 Sr/ 90 Y; Ophthalmic applicators 9 0 S r/ 90 Y; Instruments for detection of beta radiation with to the radiological protection: Ionization chambers, Geiger-Muller, etc.; Personal Dosemeters. ii) Irradiation with beta radiation of materials to the investigation. (Author)

  1. The influence of the primary solute on alpha/beta discrimination

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Carles, A.

    1998-01-01

    Naphthalene and other primary solutes are commonly used in high concentrations to increase the relative intensity of the slow component of the pulse, and consequently to enhance the spectrometer capability for alpha/beta discrimination. However, this large enhancement of the slow component generates the split of the quench curve, alpha counting efficiency vs quench parameter, for different quenchers. In this work the addition of other solutes of intermediate decay times to Insta-Gel is proposed

  2. Gross Domestic Savings and Gross Capital: what Matters to Their Formation in an Era of Economic Recession in Nigeria?

    Directory of Open Access Journals (Sweden)

    Success Abusomwan

    2017-09-01

    Full Text Available The objective of this study is to empirically investigate the long run and short run dynamic impact of interest rate and output on gross domestic savings and gross capital formation in Nigeria. Literatures, both theoretical and empirical, suggest that the rate of interest and output are the key factors influencing savings and investments. A review of factors influencing interest rates and output in Nigeria is necessitated by the recent economic downturns in Nigeria that has resulted in tight monetary policy which some commentators regard as inimical to growth. Employing Ordinary Least Squares, Co-integration, Error Correction Mechanism and Granger Causality econometric techniques on a data spanning 1981 to 2014 of the Nigerian economy sourced from the World Development Index, it was found that changes in output explains the long run and short run dynamic behaviour of gross domestic savings and gross capital formation which were used as proxies for savings and investment respectively. Whereas, a bi-causality was established between output and investment, causality flowed from output to savings in Nigeria. The research also found that interest rate is not a significant determinant of savings and investment in Nigeria in both long run and short run. It is therefore recommended that to enhance investment in a period of economic downturn in Nigeria, aggregate demand should be boosted to enhance output through vigorous pursuit of fiscal policy while implementing contractionary monetary policy to address inflationary pressures created by the increase in demand. Domestic savings will improve and gross capital formation will be sustained.

  3. Integration of radiation monitoring for nuclear emergency response teams

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, J T; Thompson, N Y [Royal Military Coll. of Canada, Kingston, ON (Canada)

    1994-12-31

    The Canadian Forces have established Nuclear Emergency Response Teams to cope with potential radiation accidents. Previously, only gamma and high-energy beta radiation could be detected. Recently, new radiation sampling, detecting, and analytical equipment has been bought, including air samplers, beta counters, high-purity germanium gamma detectors, and multi-channel analyzers together with Gamma Vision Software to analyze gamma spectra. The purpose of the present study is to propose a way to use the new equipment, to analyze the results from the gamma and beta detectors, and to integrate the results into a format for decision making. Integration is achieved through the creation of a computer program, Radiation Integration Program (RIP). This program analyzes gross beta counts, and uses them to estimate danger to the thyroid. As well the results from Gamma Vision are converted from Bq to dose rate for several parts of the body. Overall gamma results affecting the thyroid are compared to the beta results to verify the initial estimations.

  4. Psychiatric Symptoms in Children with Gross Motor Problems

    Science.gov (United States)

    Emck, Claudia; Bosscher, Ruud J.; van Wieringen, Piet C. W.; Doreleijers, Theo; Beek, Peter J.

    2012-01-01

    Children with psychiatric disorders often demonstrate gross motor problems. This study investigates if the reverse also holds true by assessing psychiatric symptoms present in children with gross motor problems. Emotional, behavioral, and autism spectrum disorders (ASD), as well as psychosocial problems, were assessed in a sample of 40 children…

  5. The MAJORANA experiment: an ultra-low background search for neutrinoless double-beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, D.; Aguayo Navarrete, Estanislao; Avignone, Frank T.; Back, Henning O.; Barabash, Alexander S.; Bergevin, M.; Bertrand, F.; Boswell, M.; Brudanin, V.; Busch, Matthew; Chan, Yuen-Dat; Christofferson, Cabot-Ann; Collar, J. I.; Combs, Dustin C.; Cooper, R. J.; Detwiler, Jason A.; Doe, Peter J.; Efremenko, Yuri; Egorov, Viatcheslav; Ejiri, H.; Elliott, Steven R.; Esterline, James H.; Fast, James E.; Fields, N.; Finnerty, P.; Fraenkle, Florian; Gehman, Victor; Giovanetti, G. K.; Green, Matthew P.; Guiseppe, Vincente; Gusey, K.; Hallin, A. L.; Hazama, R.; Henning, Reyco; Hime, Andrew; Hoppe, Eric W.; Horton, Mark; Howard, Stanley; Howe, M. A.; Johnson, R. A.; Keeter, K.; Keller, C.; Kidd, Mary; Knecht, A.; Kochetov, Oleg; Konovalov, S.; Kouzes, Richard T.; LaFerriere, Brian D.; LaRoque, B. H.; Leon, Jonathan D.; Leviner, L.; Loach, J. C.; MacMullin, S.; Marino, Michael G.; Martin, R. D.; Mei, Dong-Ming; Merriman, Jason H.; Miller, M. L.; Mizouni, Leila; Nomachi, Masaharu; Orrell, John L.; Overman, Nicole R.; Poon, Alan; Perumpilly, Gopakumar; Prior, Gersende; Radford, D. C.; Rielage, Keith; Robertson, R. G. H.; Ronquest, M. C.; Schubert, Alexis G.; Shima, T.; Shirchenko, M.; Snavely, Kyle J.; Steele, David; Strain, J.; Thomas, K.; Timkin, V.; Tornow, W.; Vanyushin, I.; Varner, R. L.; Vetter, Kai; Vorren, Kris R.; Wilkerson, J. F.; Wolfe, B. A.; Yakushev, E.; Young, A.; Yu, Chang-Hong; Yumatov, Vladimir; Zhang, C.

    2012-12-01

    The observation of neutrinoless double-beta decay would resolve the Majorana nature of the neutrino and could provide information on the absolute scale of the neutrino mass. The initial phase of the Majorana Experiment, known as the Demonstrator, will house 40 kg of Ge in an ultra-low background shielded environment at the 4850' level of the Sanford Underground Laboratory in Lead, SD. The objective of the Demonstrator is to validate whether a future 1-tonne experiment can achieve a background goal of one count per tonne-year in a narrow region of interest around the 76Ge neutrinoless double-beta decay peak.

  6. Interactions between two beta-sheets. Energetics of beta/beta packing in proteins.

    Science.gov (United States)

    Chou, K C; Némethy, G; Rumsey, S; Tuttle, R W; Scheraga, H A

    1986-04-20

    The analysis of the interactions between regularly folded segments of the polypeptide chain contributes to an understanding of the energetics of protein folding. Conformational energy-minimization calculations have been carried out to determine the favorable ways of packing two right-twisted beta-sheets. The packing of two five-stranded beta-sheets was investigated, with the strands having the composition CH3CO-(L-Ile)6-NHCH3 in one beta-sheet and CH3CO-(L-Val)6-NHCH3 in the other. Two distinct classes of low-energy packing arrangements were found. In the class with lowest energies, the strands of the two beta-sheets are aligned nearly parallel (or antiparallel) with each other, with a preference for a negative orientation angle, because this arrangement corresponds to the best complementary packing of the two twisted saddle-shaped beta-sheets. In the second class, with higher interaction energies, the strands of the two beta-sheets are oriented nearly perpendicular to each other. While the surfaces of the two beta-sheets are not complementary in this arrangement, there is good packing between the corner of one beta-sheet and the interior part of the surface of the other, resulting in a favorable energy of packing. Both classes correspond to frequently observed orientations of beta-sheets in proteins. In proteins, the second class of packing is usually observed when the two beta-sheets are covalently linked, i.e. when a polypeptide strand passes from one beta-sheet to the other, but we have shown here that a large contribution to the stabilization of this packing arrangement arises from noncovalent interactions.

  7. Interaction with beta-arrestin determines the difference in internalization behavor between beta1- and beta2-adrenergic receptors.

    Science.gov (United States)

    Shiina, T; Kawasaki, A; Nagao, T; Kurose, H

    2000-09-15

    The beta(1)-adrenergic receptor (beta(1)AR) shows the resistance to agonist-induced internalization. As beta-arrestin is important for internalization, we examine the interaction of beta-arrestin with beta(1)AR with three different methods: intracellular trafficking of beta-arrestin, binding of in vitro translated beta-arrestin to intracellular domains of beta(1)- and beta(2)ARs, and inhibition of betaAR-stimulated adenylyl cyclase activities by beta-arrestin. The green fluorescent protein-tagged beta-arrestin 2 translocates to and stays at the plasma membrane by beta(2)AR stimulation. Although green fluorescent protein-tagged beta-arrestin 2 also translocates to the plasma membrane, it returns to the cytoplasm 10-30 min after beta(1)AR stimulation. The binding of in vitro translated beta-arrestin 1 and beta-arrestin 2 to the third intracellular loop and the carboxyl tail of beta(1)AR is lower than that of beta(2)AR. The fusion protein of beta-arrestin 1 with glutathione S-transferase inhibits the beta(1)- and beta(2)AR-stimulated adenylyl cyclase activities, although inhibition of the beta(1)AR-stimulated activity requires a higher concentration of the fusion protein than that of the beta(2)AR-stimulated activity. These results suggest that weak interaction of beta(1)AR with beta-arrestins explains the resistance to agonist-induced internalization. This is further supported by the finding that beta-arrestin can induce internalization of beta(1)AR when beta-arrestin 1 does not dissociate from beta(1)AR by fusing to the carboxyl tail of beta(1)AR.

  8. The Gross Motor Skills of Children with Mild Learning Disabilities

    Science.gov (United States)

    Nonis, Karen P.; Jernice, Tan Sing Yee

    2014-01-01

    Many international studies have examined the gross motor skills of children studying in special schools while local studies of such nature are limited. This study investigated the gross motor skills of children with Mild Learning Disabilities (MLD; n = 14, M age = 8.93 years, SD = 0.33) with the Test of Gross Motor Development-2 (TGMD-2, Ulrich,…

  9. Hand Monitor for Simultaneous Measurements of Alpha and Beta Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Andersson, I Oe; Braun, J; Soederlund, B

    1960-11-15

    An instrument is described which measures {alpha} and {beta} contamination of the hands simultaneously. This has been achieved by using as detectors 8 flow counters paired in 4 units of two chambers, one unit for each side of the hand. The inner chamber of every unit (adjacent to the hands) delivers {alpha}-pulses, the outer chambers deliver {beta}-pulses. When two finger contacts are pushed the detectors are closing around the hands and the measurement is started. Audible and visual warnings operate when the MPL is exceeded. Similar warnings ope.rate if hands are removed before the end of the counting period. The activity levels are logarithmically indicated on four pointer instruments, which are automatically zeroed when the next measurement is started. The instrument is now commercially available.

  10. Gerda: A new 76Ge Double Beta Decay Experiment at Gran Sasso

    International Nuclear Information System (INIS)

    Simgen, Hardy

    2005-01-01

    In the new 76 Ge double beta decay experiment Gerda [I. Abt et al., arXiv hep-ex/0404039; Gerda proposal, to be submitted to the Gran Sasso scientific committee] bare diodes of enriched 76 Ge will be operated in highly pure liquid nitrogen or argon. The goal is to reduce the background around Q ββ =2039 keV below 10 -3 counts/(kg-bar keV-bar y). With presently available diodes from the Igex and HdMs experiments the current evidence for neutrinoless double beta decay [H.-V. Klapdor-Kleingrothaus, et al., Mod. Phys. Lett. A16 (2001) 2409ff] can unambigously be checked within one year of measurement

  11. The relationship between gross motor skills and visual perception of preschoolers

    OpenAIRE

    TEPELI, Kezban

    2014-01-01

    Answers were searched for these questions; “Is there a relationship between visual perceptions and gross motor skills of preschool children?”, “Are preschool children's visual perceptions predictors of their gross motor skills?”, “Is there any difference between visual perceptions of the children having low, average and high level of gross motor skills?” within this study where the relationship between preschool children's visual perceptions and their gross motor skills were compara...

  12. (-)[125I]-iodopindolol, a new highly selective radioiodinated beta-adrenergic receptor antagonist: measurement of beta-receptors on intact rat astrocytoma cells

    International Nuclear Information System (INIS)

    Barovsky, K.; Brooker, G.

    1980-01-01

    (-)-Pindolol, one of the most potent beta-adrenergic receptor antagonists, was radioiodinated using chloramine-T oxidation of carrier-free Na 125I and separated from unreacted pindolol to yield 2200 Ci/mmole (-)-[125I]-iodopindolol ((-)-[125I]-IPin). Mass and ultraviolet spectra confirmed that the iodination occurred on the indole ring, presumably at the 3 position. The binding of radiolabeled (-)-[125I]-IPin to beta-adrenergic receptors has been studied using intact C6 rat astrocytoma cells (2B subclone) grown in monolayer cultures. Binding of (-)[125IPin was saturable with time and concentration. Using 13 pM (-)-[125I]IPin, binding equilibrium was reached in 90 min at 21-22 degrees C. The reverse rate constant was 0.026 min-1 at 21 0 C. Specific binding (expressed as 1 microM(-)-propranolol displaceable counts) of (-)-[125I]-IPin was 95% of total binding. Scatchard analysis of (-)-[125I]-I]Pin binding revealed approximately 4300 receptors/cell and a dissociation constant of 30 pM. This was in excellent agreement with the kinetically determined dissociation constant of 35 pM. Displacement by propranolol and isoproterenol showed that (-)-[125I]-IPin binding sites were pharmacologically and stereospecifically selective. These results indicate that (-)-[125I]-IPin, a pure (-)-stereoisomer, high specific activity radioligand, selectively binds to beta-adrenergic receptors in whole cells with a high percentage of specific binding and should therefore be useful in the study and measurement of cellular beta-adrenergic receptors

  13. National pattern for the realization of the unit of the dose speed absorbed in air for beta radiation. (Method: Ionometer, cavity of Bragg-Gray implemented in an extrapolation chamber with electrodes of variable separation, exposed to a field of beta radiation of {sup 90}Sr/{sup 90}Y); Patron Nacional para la realizacion de la unidad de la rapidez de dosis absorbida en aire para radiacion beta. (Metodo: Ionometrico, cavidad de Bragg-Gray implementada en una camara de extrapolacion con electrodos de separacion variable, expuesta a un campo de radiacion beta de {sup 90}Sr/{sup 90}Y)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, M T; Morales P, J R [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2001-01-15

    From the year of 1987 the Department of Metrology of the ININ, in their Secondary Laboratory of Calibration Dosimetric, has a patron group of sources of radiation beta and an extrapolation chamber of electrodes of variable separation.Their objective is to carry out of the unit of the dose speed absorbed in air for radiation beta. It uses the ionometric method, cavity Bragg-Gray in the extrapolation chamber with which it counts. The services that offers are: i) it Calibration : Radioactive Fuentes of radiation beta, isotopes: {sup 90}Sr/{sup 90}Y; Ophthalmic applicators {sup 9}0{sup S}r/{sup 90}Y; Instruments for detection of beta radiation with to the radiological protection: Ionization chambers, Geiger-Muller, etc.; Personal Dosemeters. ii) Irradiation with beta radiation of materials to the investigation. (Author)

  14. Rapid screening of radioactivity in food for emergency response.

    Science.gov (United States)

    Bari, A; Khan, A J; Semkow, T M; Syed, U-F; Roselan, A; Haines, D K; Roth, G; West, L; Arndt, M

    2011-06-01

    This paper describes the development of methods for the rapid screening of gross alpha (GA) and gross beta (GB) radioactivity in liquid foods, specifically, Tang drink mix, apple juice, and milk, as well as screening of GA, GB, and gamma radioactivity from surface deposition on apples. Detailed procedures were developed for spiking of matrices with (241)Am (alpha radioactivity), (90)Sr/(90)Y (beta radioactivity), and (60)Co, (137)Cs, and (241)Am (gamma radioactivity). Matrix stability studies were performed for 43 days after spiking. The method for liquid foods is based upon rapid digestion, evaporation, and flaming, followed by gas proportional (GP) counting. For the apple matrix, surface radioactivity was acid-leached, followed by GP counting and/or gamma spectrometry. The average leaching recoveries from four different apple brands were between 63% and 96%, and have been interpreted on the basis of ion transport through the apple cuticle. The minimum detectable concentrations (MDCs) were calculated from either the background or method-blank (MB) measurements. They were found to satisfy the required U.S. FDA's Derived Intervention Levels (DILs) in all but one case. The newly developed methods can perform radioactivity screening in foods within a few hours and have the potential to capacity with further automation. They are especially applicable to emergency response following accidental or intentional contamination of food with radioactivity. Published by Elsevier Ltd.

  15. Rapid screening of radioactivity in food for emergency response

    International Nuclear Information System (INIS)

    Bari, A.; Khan, A.J.; Semkow, T.M.; Syed, U.-F.; Roselan, A.; Haines, D.K.; Roth, G.; West, L.; Arndt, M.

    2011-01-01

    This paper describes the development of methods for the rapid screening of gross alpha (GA) and gross beta (GB) radioactivity in liquid foods, specifically, Tang drink mix, apple juice, and milk, as well as screening of GA, GB, and gamma radioactivity from surface deposition on apples. Detailed procedures were developed for spiking of matrices with 241 Am (alpha radioactivity), 90 Sr/ 90 Y (beta radioactivity), and 60 Co, 137 Cs, and 241 Am (gamma radioactivity). Matrix stability studies were performed for 43 days after spiking. The method for liquid foods is based upon rapid digestion, evaporation, and flaming, followed by gas proportional (GP) counting. For the apple matrix, surface radioactivity was acid-leached, followed by GP counting and/or gamma spectrometry. The average leaching recoveries from four different apple brands were between 63% and 96%, and have been interpreted on the basis of ion transport through the apple cuticle. The minimum detectable concentrations (MDCs) were calculated from either the background or method-blank (MB) measurements. They were found to satisfy the required U.S. FDA's Derived Intervention Levels (DILs) in all but one case. The newly developed methods can perform radioactivity screening in foods within a few hours and have the potential to capacity with further automation. They are especially applicable to emergency response following accidental or intentional contamination of food with radioactivity.

  16. An automatic counting and recording system (1963); Ensemble de comptage a enregistrement automatique (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Pierre, B. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-09-15

    An automatic control, counting and programing system for the collection of single crystal diffractometry data was designed by the author for a neutron diffractometer in 1958 at C.E.N - Grenoble. A part of the whole instrument, 'The Automatic Counting and Recording System', is described in this paper. Its applications are numerous and extensive, e.g.: the system has been designed for neutron diffractometer, but it can easily be adapted either for use with X-rays or measurement of mean life in {beta} decay analysis. (author) [French] Un ensemble automatique de telecommande, comptage et programmation pour la diffractometrie a cristal unique a ete etudie et realise par l'auteur pour la diffraction des neutrons en 1958 au C.E.N - Grenoble. Le present rapport decrit a ''l'Ensemble de Comptage a Enregistrement Automatique'' qui est une partie de l'appareillage complet. Ses applications sont nombreuses et peuvent s'etendre a de nouveaux domaines. En effet cet ensemble qui a ete etudie pour fonctionner avec un diffractometre a neutron, peut facilement s'adapter a la technique de diffraction des rayons X ou par exemple a celle de decroisasnce d'activite {beta}. (auteur)

  17. [The physical therapy undergraduate students' responses to the gross human anatomy subjects].

    Science.gov (United States)

    Anahara, Reiko; Kawashiro, Yukiko; Matsuno, Yoshiharu; Mori, Chisato; Kohno, Toshihiko

    2008-09-01

    Instruction in gross human anatomy is one of the important items in the subject for co-medical students of the physical therapist course. The physical therapy undergraduate students are required to have a solid understanding of the structure and formation of the human body. Therefore, their good-understanding of the course on the gross human anatomy and their experience of the gross human anatomy laboratory (observation practice) are acquired to improve their knowledge of the human body. To clarify the student responses to the gross human anatomy course including the gross human anatomy laboratory, several questionnaires were administered to the freshman physical therapy undergraduate student for two years. We found that more than 80% of the students, who felt a negative attitude for gross human anatomy before the course started, had a positive attitude about the gross human anatomy after going through the course. The experience of the gross human anatomy laboratory increased the students' activity of learning and they thought more about the dignity of being human after the course than before viewing. In addition, the results suggested that the multiple experiences of the gross human anatomy course are useful for the physical therapy undergraduate students to improve the quality of their understanding of the human body.

  18. Pricing, renegotiation and gross inequities

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, J.S. (Van Cott, Bagley, Cornwall McCarthy, Salt Lake City, UT (USA))

    1990-01-01

    Reviews pricing, renegotiation and gross inequity provisions of coal supply agreements in order to provide practical assistance to an attorney called upon to draft in written form the intent of buyer and seller. 26 refs.

  19. Comprehensive applications of the gas flow proportional counters for radiological surveillance

    International Nuclear Information System (INIS)

    Babu, D.A.R.; Raman, Anand; Ashokkumar, P.; Sharma, D.N.

    2008-01-01

    Gas Flow Proportional Counters (GFPC) have been developed indigenously for various radiation protection applications. These detectors can be fabricated for 2 inches diameter filter paper sample counting applications to large area (∼1500 cm 2 ) detectors for surface contamination applications. Thin entrance windows allow non penetrating type of radiations like alpha and low energy beta particles, Efficiencies (for alpha and beta radiations) are comparable to conventional detectors used to measure these radiations. Poor gamma efficiency ( 2 /γ ratio, a high figure of merit and enables efficient gamma background rejection. These detectors are quite suitable for Indian environmental conditions. Three systems have been developed and successfully incorporated in to the radiation surveillance program at various nuclear facilities. The systems based on GFPC detectors include: a) Multiple sample gross alpha counting system; b) Laundry monitoring system; c) Alpha hand contamination monitoring system. The first of these enables simultaneous gross alpha counting of five air activity filter paper samples. The area of the detector surface is optimized to cover the 2 inches sized filter paper samples routinely used for the purpose. Five numbers of GFPC 's are arranged sequentially coupled to five individual amplifiers - micro controller modules to process the signal from the five counters. The laundry monitor which is micro controller based system consists of four large area multiwire GFPC detectors (700 cm 2 sensitive area) used to monitor alpha contamination of decontaminated laundry, Each detector uses a charge sensitive preamplifier coupled to I 2 C counter. The alpha hand monitoring system consists of four large area multiwire gas flow proportional detectors (330 cm 2 sensitive area each). A micro controller-based module is employed to initiate the counting process automatically when the hands are inserted in to the suitably designed window slots and provides audio and

  20. Radiometric parameters in freshwater samples of Centro Experimental Aramar (CTMSP/Brazil)

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Marco Antonio P.V. [Laboratorio Radioecologico (LARE), Ipero, SP (Brazil). Dept. de Seguranca Nuclear; Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Experimental results are described obtained with gamma spectrometry, alpha and beta gross counts, liquid scintillation and fluorometry techniques for the measurement of background radiation in surface water samples, collected in Centro Experimental Aramar and surroundings, from 1988 to 2009. The estimated average background radiation concentrations in water samples in this region are low, related to the low level detection limits of the techniques, and indicates good water quality parameters, and low interference in the environment in Centro Experimental Aramar and region. (author)

  1. 26 CFR 1.872-1 - Gross income of nonresident alien individuals.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Gross income of nonresident alien individuals. 1...) INCOME TAX (CONTINUED) INCOME TAXES Nonresident Aliens and Foreign Corporations § 1.872-1 Gross income of nonresident alien individuals. (a) In general—(1) Inclusions. The gross income of a nonresident alien...

  2. Current usage and future trends in gross digital photography in Canada.

    Science.gov (United States)

    Horn, Christopher L; DeKoning, Lawrence; Klonowski, Paul; Naugler, Christopher

    2014-01-14

    The purpose of this study was to assess the current usage, utilization and future direction of digital photography of gross surgical specimens in pathology laboratories across Canada. An online survey consisting of 23 multiple choice and free-text questions regarding gross digital photography was sent out to via email to laboratory staff across Canada involved in gross dissection of surgical specimens. Sixty surveys were returned with representation from most of the provinces. Results showed that gross digital photography is utilized at most institutions (90.0%) and the primary users of the technology are Pathologists (88.0%), Pathologists' Assistants (54.0%) and Pathology residents (50.0%). Most respondents felt that there is a definite need for routine digital imaging of gross surgical specimens in their practice (80.0%). The top two applications for gross digital photography are for documentation of interesting/ complex cases (98.0%) and for teaching purposes (84.0%). The main limitations identified by the survey group are storage space (42.5%) and security issues (40.0%). Respondents indicated that future applications of gross digital photography mostly include teaching (96.6%), presentation at tumour boards/ clinical rounds (89.8%), medico-legal documentation (72.9%) and usage for consultation purposes (69.5%). The results of this survey indicate that pathology staff across Canada currently utilizes gross digital images for regular documentation and educational reasons. They also show that the technology will be needed for future applications in teaching, consultation and medico-legal purposes.

  3. Liquid scintillation alpha spectrometry techniques

    International Nuclear Information System (INIS)

    McKlveen, J.W.; McDowell, W.J.

    1984-01-01

    Accurate, quantitative determinations of alpha emitting nuclides by conventional plate counting methods are difficult, because of sample self-absorption problems in counting and because of non-reproducible losses in conventional sample separation methods. Liquid scintillation alpha spectrometry offers an attractive alternative with no sample self-absorption or geometry problems and with 100% counting efficiency. Sample preparation may include extraction of the alpha emitter of interest by a specific organic phase-soluble compound directly into the liquid scintillation counting medium. Detection electronics use energy and pulse-shape discrimination, to yield alpha spectra without beta and gamma background interference. Specific procedures have been developed for gross alpha, uranium, plutonium, thorium and colonium assay. Possibilities for a large number of other applications exist. Accuracy and reproducibility are typically in the 1% range. Backgrounds of the order of 0.01 cpm are readily achievable. The paper will present an overview of liquid scintillation alpha counting techniques and some of the results achieved for specific applications. (orig.)

  4. Determination of the neutrino mass from the beta decay of gaseous molecular tritium

    International Nuclear Information System (INIS)

    Decman, D.J.; Stoeffl, W.

    1992-06-01

    We set an upper limit of 8 eV for the mass of the electron antineutrino from studying the beta decay of tritium. We use a gaseous molecular tritium source, a high resolution magnetic spectrometer and a low background counting system to minimize the systematic errors encountered in these measurements. Our calibration data with radioactive 83m Kr enables us to measure our system response function and a good deal of atomic physics data. In addition to our end point results we have made the first measurement of the tritium beta decay spectrum below 200 keV. We find an excess of very low energy electrons which arise from molecular processes of the 3 He-T + ion

  5. Better Renal Resistive Index Profile in Subjects with Beta Thalassemia Minor .

    Science.gov (United States)

    Basut, Fahrettin; Keşkek, Şakir Özgür; Gülek, Bozkurt

    2018-05-03

    Beta thalassaemia minor is a common genetic disorder without any characteristic symptoms except mild anemia. It is found to be associated with some cardiovascular risk factors such as insulin resistance and diabetes mellitus. The renal resistive index (RRI) is a measure of renal arterial resistance to blood flow. The aim of this study was to evaluate the renal resistive index in subjects with beta thalassaemia minor (BTM). A total of 253 subjects were included in this cross-sectional study. The study group consisted of 148 subjects with BTM and the control group consisted of 105 healthy subjects. Beta thalassaemia minor was diagnosed by complete blood count and hemoglobin electrophoresis. Blood pressure measurement and biochemical tests were performed. Renal resistive index of all subjects was measured using renal Doppler ultrasonography. Subjects with beta thalassemia minor had lower renal resistive indices compared to healthy subjects (0.58 ± 0.04 vs. 0.60 ± 0.06, p = 0.0016). Additionally, the RRI levels of subjects with BTM were correlated with systolic blood pressure (p = 0.017, r = 0.194). In this study, lower renal resistive index was found in subjects with BTM. This may be associated with decreased vascular resistance and blood viscosity in these subjects. ©2018The Author(s). Published by S. Karger AG, Basel.

  6. Aerial radiological measuring system program

    International Nuclear Information System (INIS)

    Doyle, J.F.; Boyns, P.K.

    1972-01-01

    The present ARMS aircraft has an effective survey time of four hours. Typical survey altitudes are 300 to 500 feet for terrain surveys and up to 20,000 feet for cloud tracks. A number of special airframe modifications have been made to accommodate the various sensor systems. The ARMS radiation measurement system consists of fourteen 4-inch diameter by 4-inch thick sodium iodide (NaI) detectors, a summing network for the detector signals, single and multichannel analyzers, analog computers, digital display and recording equipment, a doppler radar position computer, and strip chart recorders. Major subsystems include meteorology sensors, multispectral camera systems, and an infrared scanner for thermal mapping. Additional radiation detectors include an alpha spectrometer and a beta counter, used to count filter samples taken from a 150 cfm air sampler, which is a permanent part of the aircraft. A small lead shield houses a 1 / 2 -in. x 3-in. NaI crystal for beta and gamma counting of air filter samples. Several BF 3 neutron detectors are also available for neutron counting. The raw data from the gross gamma count and the gamma spectral measurements are permanently recorded on paper tape, and they must undergo reduction and analysis for final characterization of the radiological properties of the surveyed area. (U.S.)

  7. Sequence swapping does not result in conformation swapping for the beta4/beta5 and beta8/beta9 beta-hairpin turns in human acidic fibroblast growth factor.

    Science.gov (United States)

    Kim, Jaewon; Lee, Jihun; Brych, Stephen R; Logan, Timothy M; Blaber, Michael

    2005-02-01

    The beta-turn is the most common type of nonrepetitive structure in globular proteins, comprising ~25% of all residues; however, a detailed understanding of effects of specific residues upon beta-turn stability and conformation is lacking. Human acidic fibroblast growth factor (FGF-1) is a member of the beta-trefoil superfold and contains a total of five beta-hairpin structures (antiparallel beta-sheets connected by a reverse turn). beta-Turns related by the characteristic threefold structural symmetry of this superfold exhibit different primary structures, and in some cases, different secondary structures. As such, they represent a useful system with which to study the role that turn sequences play in determining structure, stability, and folding of the protein. Two turns related by the threefold structural symmetry, the beta4/beta5 and beta8/beta9 turns, were subjected to both sequence-swapping and poly-glycine substitution mutations, and the effects upon stability, folding, and structure were investigated. In the wild-type protein these turns are of identical length, but exhibit different conformations. These conformations were observed to be retained during sequence-swapping and glycine substitution mutagenesis. The results indicate that the beta-turn structure at these positions is not determined by the turn sequence. Structural analysis suggests that residues flanking the turn are a primary structural determinant of the conformation within the turn.

  8. Preliminary results from a study of the double beta decay of 150Nd

    International Nuclear Information System (INIS)

    Perillo, I.M.C.; Chan, Y.D.; Hurley, D.; Lesko, K.T.; McDonald, R.J.; Moorhead, M.E.; Norman, E.B.; Smith, A.R.; Stokstad, R.G.

    1996-01-01

    We report the preliminary results from a study of the double beta decay of 150 Nd to the first 0 + excited state of 150 Sm. Our data consists of 50 days of counting 5 kg of natural Nd 2 O 3 at the LBNL-Oroville low background facility. The deduced lower limit for the half life of this decay mode is 4.9.10 19 years. (orig.)

  9. A preliminary investigation of radiation level and some radionuclides in imported food and food products

    International Nuclear Information System (INIS)

    Sinakhom, F.; Mongkolphantha, S.

    1980-04-01

    A preliminary study of gross beta activity and content of some long-lived radionuclides associated with fission products in various types of imported food and food-products was carried out. Food samples were purchased monthly during 1976-1977 from general well-known supermarkets and local grocery stores up to a total of 89 samples. The gamma spectrum of long-lived radionuclides was searched using a 128 channel analyzer coupled with 3'' x 3'' NaI (T1) crystal detector. Two radionuclides were frequently found to be present in these food samples, viz. potassium-40 and cesium-137 and their concentrations were subsequently determined. The limits of detection under the conditions used for potassium-40 and cesium-137 were 0.04 and 0.03 pCi/g-wet weight, respectively. Samples were dry-ashed and counted for gross beta activity utilizing a low background anti-coincidence G.M. counter. The content of strontium-90 was also investigated concurrently by solvent extraction technique employing tri-n-butyl phosphate as an extractant. Results of the study are tabulated. (author)

  10. Search for $\\beta$-delayed protons from $^{11}$Be

    CERN Multimedia

    $\\beta$-delayed proton emission from $^{11}$Be will be a very rare process. It is believed to decay directly into continuum states. This would imply that it will be a sensitive probe of the halo structure of the one-neutron halo nucleus $^{11}$Be. We propose to improve existing (unpublished) limits on this decay mode by two orders of magnitude. Our earlier experience at ISOLDE indicates that the required intensity and purity of the source can be obtained. The branching ratio will be measured by counting the number of $^{10}$Be atoms produced via accelerator mass spectrometry.

  11. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  12. Expression of transforming growth factor beta (TGF beta) receptors and expression of TGF beta 1, TGF beta 2 and TGF beta 3 in human small cell lung cancer cell lines

    DEFF Research Database (Denmark)

    Damstrup, L; Rygaard, K; Spang-Thomsen, M

    1993-01-01

    A panel of 21 small cell lung cancer cell (SCLC) lines were examined for the presence of Transforming growth factor beta receptors (TGF beta-r) and the expression of TGF beta mRNAs. By the radioreceptor assay we found high affinity receptors to be expressed in six cell lines. scatchard analysis......(r) = 65,000 and 90,000 and the betaglycan (type III) with M(r) = 280,000. Northern blotting showed expression of TGF beta 1 mRNA in ten, TGF beta 2 mRNA in two and TGF beta 3 mRNA in seven cell lines. Our results provide, for the first time, evidence that a large proportion of a broad panel of SCLC cell...... lines express TGF beta-receptors and also produce TGF beta mRNAs....

  13. 26 CFR 1.61-14 - Miscellaneous items of gross income.

    Science.gov (United States)

    2010-04-01

    ... as treble damages under the antitrust laws and exemplary damages for fraud are gross income. Another... by law. Illegal gains constitute gross income. Treasure trove, to the extent of its value in United...

  14. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  15. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  16. 26 CFR 1.993-6 - Definition of gross receipts.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 10 2010-04-01 2010-04-01 false Definition of gross receipts. 1.993-6 Section 1.993-6 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Domestic International Sales Corporations § 1.993-6 Definition of gross receipts. (a...

  17. Guidelines for Standard Photography in Gross and Clinical Anatomy

    Science.gov (United States)

    Barut, Cagatay; Ertilav, Hakan

    2011-01-01

    Photography has a widespread usage in medicine and anatomy. In this review, authors focused on the usage of photography in gross and clinical anatomy. Photography in gross and clinical anatomy is not only essential for accurate documentation of morphological findings but also important in sharing knowledge and experience. Photographs of cadavers…

  18. Primary standardization of {sup 152}Eu by 4πβ(LS) - γ (NaI) coincidence counting and CIEMAT-NIST method

    Energy Technology Data Exchange (ETDEWEB)

    Ruzzarin, A., E-mail: aruzzarin@nuclear.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (LIN/PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear; Cruz, P.A.L. da; Ferreira Filho, A.L.; Iwahara, A. [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiações Ionizantes

    2017-07-01

    The 4πβ-γ coincidence counting and CIEMAT/NIST liquid scintillation method were used in the standardization of a solution of {sup 152}Eu. In CIEMAT/NIST method, measurements were performed in a Liquid Scintillation Counter model Wallac 1414. In the 4πβ-γ coincidence counting, the solution was standardized using a coincidence method with 'beta-efficiency extrapolation'. A simple 4πβ-γ coincidence system was used, with acrylic scintillation cell coupled to two coincident photomultipliers at 180° each other and NaI(Tl) detector. The activity concentrations obtained were 156.934 ± 0.722 and 157.403 ± 0.113 kBq/g, respectively, for CIEMAT/NIST and 4πβ-γ coincidence counting measurement methods. (author)

  19. Beta decay heat following U-235, U-238 and Pu-239 neutron fission

    Science.gov (United States)

    Li, Shengjie

    1997-09-01

    This is an experimental study of beta-particle decay heat from 235U, 239Pu and 238U aggregate fission products over delay times 0.4-40,000 seconds. The experimental results below 2s for 235U and 239Pu, and below 20s for 238U, are the first such results reported. The experiments were conducted at the UMASS Lowell 5.5-MV Van de Graaff accelerator and 1-MW swimming-pool research reactor. Thermalized neutrons from the 7Li(p,n)7Be reaction induced fission in 238U and 239Pu, and fast neutrons produced in the reactor initiated fission in 238U. A helium-jet/tape-transport system rapidly transferred fission fragments from a fission chamber to a low background counting area. Delay times after fission were selected by varying the tape speed or the position of the spray point relative to the beta spectrometer that employed a thin-scintillator-disk gating technique to separate beta-particles from accompanying gamma-rays. Beta and gamma sources were both used in energy calibration. Based on low-energy(energies 0-10 MeV. Measured beta spectra were unfolded for their energy distributions by the program FERD, and then compared to other measurements and summation calculations based on ENDF/B-VI fission-product data performed on the LANL Cray computer. Measurements of the beta activity as a function of decay time furnished a relative normalization. Results for the beta decay heat are presented and compared with other experimental data and the summation calculations.

  20. Beta-energy averaging and beta spectra

    International Nuclear Information System (INIS)

    Stamatelatos, M.G.; England, T.R.

    1976-07-01

    A simple yet highly accurate method for approximately calculating spectrum-averaged beta energies and beta spectra for radioactive nuclei is presented. This method should prove useful for users who wish to obtain accurate answers without complicated calculations of Fermi functions, complex gamma functions, and time-consuming numerical integrations as required by the more exact theoretical expressions. Therefore, this method should be a good time-saving alternative for investigators who need to make calculations involving large numbers of nuclei (e.g., fission products) as well as for occasional users interested in restricted number of nuclides. The average beta-energy values calculated by this method differ from those calculated by ''exact'' methods by no more than 1 percent for nuclides with atomic numbers in the 20 to 100 range and which emit betas of energies up to approximately 8 MeV. These include all fission products and the actinides. The beta-energy spectra calculated by the present method are also of the same quality

  1. Oropharyngeal dysphagia and gross motor skills in children with cerebral palsy.

    Science.gov (United States)

    Benfer, Katherine A; Weir, Kelly A; Bell, Kristie L; Ware, Robert S; Davies, Peter S W; Boyd, Roslyn N

    2013-05-01

    To determine the prevalence of oropharyngeal dysphagia (OPD) and its subtypes (oral phase, pharyngeal phase, saliva control), and their relationship to gross motor functional skills in preschool children with cerebral palsy (CP). It was hypothesized that OPD would be present across all gross motor severity levels, and children with more severe gross motor function would have increased prevalence and severity of OPD. Children with a confirmed diagnosis of CP, 18 to 36 months corrected age, born in Queensland between 2006 and 2009, participated. Children with neurodegenerative conditions were excluded. This was a cross-sectional population-based study. Children were assessed by using 2 direct OPD measures (Schedule for Oral Motor Assessment; Dysphagia Disorders Survey), and observations of signs suggestive of pharyngeal phase impairment and impaired saliva control. Gross motor skills were described by using the Gross Motor Function Measure, Gross Motor Function Classification System (GMFCS), Manual Ability Classification System, and motor type/ distribution. OPD was prevalent in 85% of children with CP, and there was a stepwise relationship between OPD and GMFCS level. There was a significant increase in odds of having OPD, or a subtype, for children who were nonambulant (GMFCS V) compared with those who were ambulant (GMFCS I) (odds ratio = 17.9, P = .036). OPD was present across all levels of gross motor severity using direct assessments. This highlights the need for proactive screening of all young children with CP, even those with mild impairments, to improve growth and nutritional outcomes and respiratory health.

  2. Neutrinoless double beta decay with 82SeF6 and direct ion imaging

    Science.gov (United States)

    Nygren, D. R.; Jones, B. J. P.; López-March, N.; Mei, Y.; Psihas, F.; Renner, J.

    2018-03-01

    We present a new neutrinoless double beta decay concept: the high pressure selenium hexafluoride gas time projection chamber. A promising new detection technique is outlined which combines techniques pioneered in high pressure xenon gas, such as topological discrimination, with the high Q-value afforded by the double beta decay isotope 82Se. The lack of free electrons in SeF6 mandates the use of an ion TPC. The microphysics of ion production and drift, which have many nuances, are explored. Background estimates are presented, suggesting that such a detector may achieve background indices of better than 1 count per ton per year in the region of interest at the 100 kg scale, and still better at the ton-scale.

  3. Speculative Betas

    OpenAIRE

    Harrison Hong; David Sraer

    2012-01-01

    We provide a model for why high beta assets are more prone to speculative overpricing than low beta ones. When investors disagree about the common factor of cash-flows, high beta assets are more sensitive to this macro-disagreement and experience a greater divergence-of-opinion about their payoffs. Short-sales constraints for some investors such as retail mutual funds result in high beta assets being over-priced. When aggregate disagreement is low, expected return increases with beta due to r...

  4. Environmental radioactivity in Turkey, 2007

    International Nuclear Information System (INIS)

    2009-01-01

    In this report, the activity concentrations of natural and artificial radionuclides, gross alpha/beta activities and air gamma dose rates in the environmental and food samples provided from Turkey's seven geographical regions within the environmental radioactivity monitoring program in 2007 are presented. The activity concentrations of the natural ( 238 U, 232 Th, 2 26Ra, 4 :0K and 7 Be) and artificial ( 137 Cs, 134 Cs, 90 Sr, 238-239+240 Pu, 2 41Am) radionuclides and gross alpha/beta activities in the samples were measured by using the gamma spectrometry, the alpha spectrometry, the liquid scintillation counter and the gross alpha /beta counting system. Results show that 137 Cs and 9 0Sr radionuclides originating from the Chernobyl Nuclear Reactor accident in 1986 exist in some of samples even in low levels. The mean activity concentrations of 238 U, 232 Th, 226 Ra and 40 K in the studied surface soil samples were found as 32.1 Bq kg -1 , 35.0 Bq kg -1 , 29.0 Bq kg -1 and 446.7 Bq kg -1 , respectively, while the mean activity concentrations of the fission product 1 37Cs was found as 18.4 Bq kg -1 . While the activity concentrations of 238 U, 232 Th and 226 Ra in the analyzed food samples are lower than the minimum detectable activity (MDA), 134 Cs and 7 Be radionuclides are not observed. The mean activity concentrations of 137 Cs and 90 Sr radionuclides are 0.24 Bq L - 1 and 0.05 Bq L - 1, respectively. (Includes 4 tables and 7 figures)

  5. Labelling of. beta. -endorphin (. beta. -END) and. beta. -lipotropin (. beta. -LPH) by /sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Deby-Dupont, G.; Joris, J.; Franchimont, P. (Universite de Liege (Belgique)); Reuter, A.M.; Vrindts-Gevaert, Y. (Institut des Radioelements, Fleurus (Belgique))

    1983-01-01

    5 ..mu..g of human ..beta..-endorphin were labelled with 2 mCi /sup 125/I by the chloramine T technique. After two gel filtrations on Sephadex G-15 and on Sephadex G-50 in phosphate buffer with EDTA, Trasylol and mercapto-ethanol, a pure tracer was obtained with a specific activity about 150 ..mu..Ci/..mu..g.Kept at + 4/sup 0/C, the tracer remained utilizable for 30 days without loss of immunoreactivity. The labelling with lactoperoxydase and the use of another gel filtration method (filtration on Aca 202) gave a /sup 125/I ..beta..-END tracer with the same immunoreactivity. The binding of this tracer to the antibody of an anti-..beta..-END antiserum diluted at 1/8000 was 32% with a non specific binding of 2%. 5 ..mu..g of human ..beta..-lipotropin were labelled with 0.5 mCi /sup 125/I by the lactoperoxydase method. After two gel filtrations on Sephadex G-25 and on Sephadex G-75 in phosphate buffer with EDTA, Trasylol and mercapto-ethanol, a pure tracer with a specific activity of 140 ..mu..Ci/..mu..g was obtained. It remained utilizable for 30 days when kept at + 4/sup 0/C. Gel filtration on Aca 202 did not give good purification, while gel filtration on Aca 54 was good but slower than on Sephadex G-75. The binding to antibody in absence of unlabelled ..beta..-LPH was 32% for an anti-..beta..-LPH antiserum diluted at 1/4000. The non specific binding was 2.5%.

  6. Carbohydrate counting for children with diabetes type 1

    Directory of Open Access Journals (Sweden)

    Juanita Mena-Gallego

    2014-12-01

    Full Text Available Type 1 Diabetes Mellitus (DM1 is an endocrine disease with autoimmune bases that mainly affects children and adolescents. It is characterized by progressive loss of beta cells mass to a critical level where the ability to release the insulin, needed for the utilization of glucose by tissues, is affected, triggering microvascular damage, main long-term complication. Short-term complications are diabetic keto-acidosis and, secondary to insulin therapy, the hypoglycemia. Although insulin therapy is the mainstay of treatment, sometimes it is difficult to calculate the proper dosage for precise glycemic control; carbohydrate counting plays an important role here in the optimization of postprandial glycemic levels, which is demonstrated by the correct levels of glycosylated hemoglobin (HbA1c. This review seeks to assess the available scientific evidence on the effectiveness of carbohydrate counting in children with DM1. Search until May 2014 was conducted in PubMed, Trip database, Cochrane and academic Google; three clinical trials performed in individuals under 18 were found. The studies demonstrate effectiveness but the quality is not strong enough. No systematic reviews were found. A more exhaustive search and possibly more clinical trials are needed to be recommended as a technique of metabolic control of Type 1 Diabetes Mellitus in children.

  7. Premarital Screening of Beta Thalassemia Minor in north-east of Iran

    Science.gov (United States)

    Hashemizadeh, H; Noori, R

    2013-01-01

    Background Beta thalassemia is a preventable disease. Iran has about 20,000Patients who are homozygote for β-thalassaemia and 3,750,000 carriers. The aim of this study was to determine the prevalence of beta thalassemia minor among men who underwent premarital screening in Quchana city in Khorasan Razavi region of Iran Materials and Methods This research is a descriptive cross-sectional study. From 2010 to 2011, all participants (1000) under marriage coming to health center of Quchan underwent routine mandatory tests. Participants were considered to have beta-thalassemia minor on the condition that hey had a mean corpuscular volume (MCV) 3.5%. Venous blood was taken into an EDTA tube and the complete blood count and red blood cell indices were measured with a Coulter automated cell counter. Electrophoresis was performed on cellulose acetate. Results Mean and SD of hemoglobin, MCV and MCH were 16±2.9, 91±4 and 28.4±2, respectively. Hemoglobin A2 Higher than 3.5 percent was reported as 3.5%.The prevalence of beta-thassemia minor with high hemoglobin A2 and microcytic hypochromic anemia was 3.5% (P-value). Conclusion In countries with high prevalence of hemoglobinopathies, a premarital screening program is helpful for identification and prevention of high-risk marriages. Detecting carrier couples with premarital screening program is an effective way of controlling thalassemia major. PMID:24575266

  8. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  9. Evaluation of free i-applications for tertiary level gross anatomy education

    Directory of Open Access Journals (Sweden)

    Matthew F. Pollard

    2012-04-01

    Full Text Available BackgroundThe use of electronic resources in education, including i-applications used on portable handheld devices, is increasing. Apple® handheld devices are popular, with free applications the most prevalent download form. Many gross anatomy i-applications are available, however no information on the quality of free anatomy products is available. Rating such products could therefore guide product recommendations.AimTo evaluate the quality and range of free iPod® applications that are applicable for tertiary level gross anatomy education.MethodsA search of the iTunes® Application Store with keywords anatomy, free, medical, functional, clinical, gross, and human was performed, with inclusion based on free applications containing human gross anatomy usable for tertiary education purposes. Application specification was noted; each was trialled independently and rated for usability, specification, academic level, and quality (image and programme.ResultsSixty-three applications were identified and eleven met inclusion criteria. Two provided gross anatomy of the entire body, nine examined specific regions or systems. Five were judged introductory in academic level, five intermediate, and one advanced. One application was rated low quality, and four excellent. None were considered difficult to use (six easy, five medium. Application size ranged between 1.2MB and 229MB (mean 27MB.ConclusionsThere are few free i-applications for learning gross anatomy and most concentrate on individual body systems, with the academic level and usability of all products well rated. Results suggest some free I-applications could be suitable adjuncts for gross anatomy education at both an undergraduate and graduate level.

  10. Prevalence of Beta-Thalassemia in premarital screening in Al-Hassa, Saudi Arabia

    International Nuclear Information System (INIS)

    Al-Suliman, A.

    2006-01-01

    The Al-Hassa area is one of the regions in Saudi Arabia where hemoglobinopathies are prevalent. The Saudi Ministry of Health designed a protocol for premarital testing after the royal decree in December 2003. The protocol was implemented in a February 2004 order. The aim of this study was to determine the prevalence of beta-thalassemia trait among subjects coming for premarital screening in the Al-Hassa area. From February 2004 to November 2004, healthy subjects coming to six marriages consultation centers in the Al-Hassa area underwent routine mandatory tests. Subjects were considered to have beta-thalassemia trait if they had a mean corpuscular volume (MCV), 80 fL and/or a mean corpuscular hemoglobin (MCH) 3.2%. Venous blood was taken into ETDA tube and the complete blood count and red blood cell indices were measured by a Coulter automated cell counter on the same day of hemoglobin collection. Electrophoresis was done on cellulose acetate. All Saudi participants (n=8918), including 4218 (47.3%) males and 4700 (52.7%) females were screened. The prevalence of beta-thalassemia trait with high hemoglobin A2 and microcytic hypochromic anemia was 3.4% (307/8918). In countries with a high prelevance of hemoglobinopathies, a premarital screening program is helpful for identification and prevention of high-risk marriages. With a 3.4% prevalence of beta-thalassemia trait in premarital couples, future comprehensive programs are needed to know the actual prevalence of beta-thalassemia in Al-Hassa. (author)

  11. Doğu Karadeniz Bölgesinin Doğal Kaynak Sularındaki Toplam Alfa ve Toplam Beta Aktivite Dağılımlarının Bulanık Mantık Yöntemi ile Değerlendirilmesi ve Haritalandırılması

    Directory of Open Access Journals (Sweden)

    Cafer Mert YEŞİLKANAT

    2016-11-01

    Full Text Available Özet: Bu çalışmada bulanık mantık yaklaşımı kullanarak, Doğu karadeniz bölgesindeki doğal kaynak sularından ölçülen toplam alfa ve toplam beta aktivite konsantrasyonlarının genel dağılımı belirlenmiş ve ölçüm alınmayan noktalar için tahmin değerleri hesaplanarak, haritalandırılması gerçekleştirilmiştir. Ölçümler Artvin, Rize, Trabzon, Giresun, Ordu, Gümüşhane ve Bayburt olmak üzere toplam 7 ilde belirlenen 40 istasyondan elde edilmiştir. Bu istasyonların tamamından ölçülen toplam alfa ve toplam beta aktivite değerleri bulgularından yararlanarak çalışma alanının genel yapısı için bulanık kümeler ve kural tabanları oluşturulmuştur. Bu çalışmada Doğu-Batı X koordinatı, Güney-Kuzey Y koordinatı ve yükseklik verileri ile birlikte toplam alfa ve toplam beta konsantrasyonları bulanık kümeler ile gösterilmiş ve bulanık kurallar ile tahminlerde bulunulmuştur. Bulanık modelin performans değerlendirmesi ise çapraz doğrulama diyagramları ile değerlendirilmiştir. Bu diyagramlardan toplam alfa ve toplam beta için pearson’s r katsayıları sırasıyla 0.74 ve 0.80 olarak bulunmuştur.Çalışmanın sonucunda ölçüm alınmayan tüm noktalar için bulanık mantık modellemesi tahminlerinde bulunulmuş ve sonuçlar radyolojik dağılım haritaları olarak gösterilmiştir. Bu çalışma ile radyolojik dağılımın bulanık mantık yaklaşımları kullanılarak tespit edilebileceği ve ölçüm alınmayan noktalar için tahmin değerlerinin belirli güven aralığında hesaplanabileceği gösterilmiştir.Anahtar Sözcükler: Bulanık Mantık Modellemesi, Çevresel Radyoaktivite, Doğal kaynak suyu, Doğu Karadeniz bölgesiAbstract: In the study, drawing upon the fuzzy logic approach, the general distribution of gross alpha and gross beta concentrations measured from the natural spring waters in the Eastern Black Sea region was identified, and the predicted values were

  12. Data acquisition system and analysis programme for environmental radioactivity monitoring

    International Nuclear Information System (INIS)

    Rajaram, S.; Kannan, V.; Hegde, A.G.

    2003-01-01

    Full text: In every Environmental Survey Laboratory (ESL) many nuclear radiation detecting instruments such as low level Gas Flow Beta Counting Systems, Gross Alpha Counting Systems, Gamma Counting Systems (Single Channel Analyser) are in use to detect the environmental radiation level. These instruments give output in terms of number (total pulse event counts), which is further manually converted into activity concentration per unit weight of the environmental samples. There is considerable difficulty and delay in obtaining the data, since calculations are done manually and also it is very difficult to maintain database of these results for future reference. In order to overcome all this difficulties a Data Acquisition System and Analysing Software Programme has been designed and developed. This paper describes the design and development of the Data Acquisition System using PCL-830 Counter Timer add on card, for networking the environmental radioactivity monitoring equipment's, which is under routine operation at ESL Kalpakkam

  13. Evaluation of the activity concentration of {sup 226}Ra, {sup 228}Ra and {sup 210}Pb in sediments from Antarctica in the Admiralty Bay region

    Energy Technology Data Exchange (ETDEWEB)

    Mora, Tamires de A.; Oliveira, Joselene de, E-mail: tamires.mora@usp.br, E-mail: jolivei@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Figueira, Rubens C.L.; Mahiques, Michel M.; Sousa, Silvia H.M., E-mail: rfigueira@usp.br, E-mail: mahiques@usp.br, E-mail: smsousa@usp.br [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto Oceanografico

    2015-07-01

    In this study, we performed the radiochemical characterization of a sedimentary record (1B profile), collected in the vicinity of Admiralty Bay, King George Island in Antarctic Operation XXXI (January/2013). The activities of {sup 226}Ra, {sup 228}Ra and {sup 210}Pb were determined by the counting of gross alpha and gross beta activities in the precipitates of Ba(Ra)SO{sub 4} and PbCrO{sub 4}. Those measurements were carried out in a low background gas flow proportional detector. The {sup 226}Ra and {sup 228}Ra were measured after 21 days of the final precipitation. The {sup 210}Pb activity was determined after 10 days of the precipitation date by gross beta counting of its {sup 210}Bi decay product. The activity concentration of {sup 226}Ra ranged from 11±1 (mBq g-1) to 54±3 (mBq g{sup -1}), and the {sup 228}Ra ranged from 48±5 (mBq g{sup -1}) to 155±16 (mBq g{sup -1}). The activity concentration of {sup 210}Pb varied from 8±1 (mBq g{sup -1}) to 458±46 (mBq g{sup -1}), while unsupported {sup 210}Pb ranged from 6±1 (mBq g{sup -1}) to 434±65 (mBq g{sup -1}). The {sup 210}Pb concentrations in sediments have often been used to dating events like deposition and accumulation in various marine environments. Taking into account the results of {sup 210}Pb and {sup 226}Ra activities obtained in testimony-1B it was estimated the unsupported {sup 210}Pb activity which was applied to the CIC geochronological dating model (Constant Initial Concentration). Based in these data, the sedimentation rate obtained was 0.63±0.02 cm year{sup -1}. (author)

  14. Evaluation of the activity concentration of 226Ra, 228Ra and 210Pb in sediments from Antarctica in the Admiralty Bay region

    International Nuclear Information System (INIS)

    Mora, Tamires de A.; Oliveira, Joselene de; Figueira, Rubens C.L.; Mahiques, Michel M.; Sousa, Silvia H.M.

    2015-01-01

    In this study, we performed the radiochemical characterization of a sedimentary record (1B profile), collected in the vicinity of Admiralty Bay, King George Island in Antarctic Operation XXXI (January/2013). The activities of 226 Ra, 228 Ra and 210 Pb were determined by the counting of gross alpha and gross beta activities in the precipitates of Ba(Ra)SO 4 and PbCrO 4 . Those measurements were carried out in a low background gas flow proportional detector. The 226 Ra and 228 Ra were measured after 21 days of the final precipitation. The 210 Pb activity was determined after 10 days of the precipitation date by gross beta counting of its 210 Bi decay product. The activity concentration of 226 Ra ranged from 11±1 (mBq g-1) to 54±3 (mBq g -1 ), and the 228 Ra ranged from 48±5 (mBq g -1 ) to 155±16 (mBq g -1 ). The activity concentration of 210 Pb varied from 8±1 (mBq g -1 ) to 458±46 (mBq g -1 ), while unsupported 210 Pb ranged from 6±1 (mBq g -1 ) to 434±65 (mBq g -1 ). The 210 Pb concentrations in sediments have often been used to dating events like deposition and accumulation in various marine environments. Taking into account the results of 210 Pb and 226 Ra activities obtained in testimony-1B it was estimated the unsupported 210 Pb activity which was applied to the CIC geochronological dating model (Constant Initial Concentration). Based in these data, the sedimentation rate obtained was 0.63±0.02 cm year -1 . (author)

  15. Associations between gross motor skills and physical activity in Australian toddlers.

    Science.gov (United States)

    Veldman, Sanne L C; Jones, Rachel A; Santos, Rute; Sousa-Sá, Eduarda; Pereira, João R; Zhang, Zhiguang; Okely, Anthony D

    2018-08-01

    Physical activity can be promoted by high levels of gross motor skills. A systematic review found a positive relationship in children (3-18 years) but only few studies examined this in younger children. The aim of this study was to examine the association between gross motor skills and physical activity in children aged 11-29 months. Cross-sectional study. This study involved 284 children from 30 childcare services in NSW, Australia (Mean age=19.77±4.18months, 53.2% boys). Physical activity was measured using accelerometers (Actigraph GT3X+). Gross motor skills were assessed using the Peabody Developmental Motor Scales Second Edition (PDMS-2). Multilevel linear regression analyses were computed to assess associations between gross motor skills and physical activity, adjusting for sex, age and BMI. Children spent 53.08% of their time in physical activity and 10.39% in moderate to vigorous physical activity (MVPA). Boys had higher total physical activity (pskills score was 96.16. Boys scored higher than girls in object manipulation (pskills and total physical activity or MVPA. Although gross motor skills were not associated with physical activity in this sample, stronger associations are apparent in older children. This study therefore highlights a potential important age to promote gross motor skills. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. The Comparative Accuracy of the 4 {pi} Liquid Scintillation Counting Method of Radioisotope Standardization; L'exactitude comparee de la methode de comptage 4 {pi} a scintillateurs liquides pour l'etalonnage des radioisotopes; Sravnitel'naya tochnost' 4 {pi} zhidkogo stsintillatsionnogo metoda podscheta standartiziruemykh radioizotopov; Exactitud del metodo de recuento con centelleador liquido 4 {pi} para normalizar radioisotopos, comparada con la de otros metodos

    Energy Technology Data Exchange (ETDEWEB)

    Steyn, J [National Physical Research Laboratory, Pretoria (South Africa)

    1960-06-15

    The accuracy of the 4 {pi} liquid scintillation counting method of standardizing {beta} emitters was compared to 4 l{pi} {beta}-{gamma} coincidence counting for the nuclides Co{sup 60}, I{sup 131} and Au{sup 198}. For P{sup 32} the liquid counting results were compared to 4 {pi} proportional counting. The efficiency of the liquid scintillation counting method was found to be energy dependent, dropping to about 97.5% for Co{sup 60} which was the lowest energy {beta} emitter investigated. (author) [French] La precision de la methode de comptage 4 {pi} a scintillateurs liquides pour l'etalonnage des emetteurs {beta} a ete comparee au comptage par coincidences 4 {pi} {beta}-{gamma} pour le So{sup 60}, le I{sup 131} et le Au{sup 198}. Dans le cas du P{sup 32}, les resultats du comptage au liquide ont ete compares a ceux du comptage 4 {pi} proportionnel. On a constate que le rendement de la methode de comptage a scintillateurs liquides variait en fonction de l'energie emise et qu'il descendait a environ 97.5% pour le Co{sup 60} qui, de tous les emetteurs {beta} etudies, emet l'energie la plus faible. (author) [Spanish] El autor compara la precision del metodo de recuento con centelleador iquido 4 {pi} para normalizar emisores {beta} con la del metodo de coincidencias {beta}-{gamma} 4 {pi}, para los siguientes nuclidos: So{sup 60}, I{sup 131} y Au{sup 198}. En el caso del P{sup 32}, confronta los resultados del primer metodo con los obtenidos mediante el recuento proporcional 4 {pi}. Comprueba que la eficacia del metodo de recuento con centelleador liquido depende de la energia y desciende al 97.5%, aproximadamente, para el Co{sup 60}, que fue el emisor {beta} mas debil que se investigo. (author) [Russian] Tochnost' 4 {pi} zhidkogo stsintillyatsionnog o metoda podscheta standartiziruemogo {beta}-izluchatelya sravnivalas' s 4 {pi} {beta}-{gamma} metodom podscheta na sovpadeniyakh dlya izotopov So{sup 60}, I{sup 131} i Au{sup 198}. Dlya R{sup 32} rezultaty zhidkogo

  17. Characterisation of radioactive contaminated materials by combined radiometric and spectrometric methods

    International Nuclear Information System (INIS)

    Dulama, C.; Toma, A.; Dobrin, R.; Ciocîrlan, C.; Stoica, S.; Valeca, M.; Popescu, I. I.

    2013-01-01

    In the present paper, a combined analytical methodology is described, for characterization of radioactive contaminated materials. The subject of testing activities was a set of solutions provided by the Cernavoda NPP, which are originating from processes of radiological survey of workplaces in the plant. In the introduction section, a theoretical approach was given to the origin and nature of main radionuclides occurring in the primary cooling system of the nuclear power plant, with the aim to establish selection criteria and performance requirements for the analytical methods to be used in the development of the characterization methodology. A combination of radiometric and spectrometric methods was selected, based on gross beta counting, high resolution gamma-ray spectrometry and liquid scintillation counting. (authors)

  18. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  19. Gender effects on treatment response to interferon-beta in multiple sclerosis

    DEFF Research Database (Denmark)

    Magyari, M; Koch-Henriksen, N; Laursen, B

    2014-01-01

    BACKGROUND: Gender appears to play a role in incidence and disease course of multiple sclerosis (MS). OBJECTIVE: The objective was to determine whether male and female patients with MS respond differently to interferon-beta treatment in terms of reduction in relapse rates. METHODS: We included all....... Patients served as their own controls, and relapse rates were compared between NAb-negative and NAb-positive periods. RESULTS: NAbs significantly abrogated the interferon-beta treatment efficacy in both genders. The all-over women:men relapse rate ratio irrespective of NAb status was 1.47 (95%CI; 1.......28-1.68). In a generalized linear Poisson models analysis with relapse counts as response variable, the main effects NAbs, sex, age at treatment start and number of relapses in 2 years before treatment start were strongly significant, but the effect of NAbs on relapse rates did not differ significantly between men and women...

  20. Analysis of a Gross Counting Decision Metric for use in Threat Detection During Cargo Container Inspection

    International Nuclear Information System (INIS)

    Hall, J

    2006-01-01

    LLNL is actively engaged in the development of a variety of advanced technologies for use in detecting potential threats in sea-going cargo containers, particularly the presence of hidden special nuclear materials (SNM). One such project is the so-called ''Nuclear Car Wash'' (NCW), which uses a high-energy neutron probe to scan the container. High-energy, β-delayed γ-rays emitted during the decay of short-lived, neutron-induced fission products are then taken as a signature of fissionable material. There are a number of different threat decision metrics that one could imagine using in conjunction with an inspection system such as the NCW; however, the most straightforward approach might be to simply compare the total number of counts that our detector records during some suitably chosen time interval to the average background signal that one would expect from a ''clean'' container during the same interval. The purpose of this report is to describe the basic statistical properties of a decision metric of this sort and outline the procedures for using it in experimental practice

  1. Assessment of affinities of beta-CIT, beta-CIT-FE, and beta-CIT-FP for monoamine transporters permanently expressed in cell lines

    International Nuclear Information System (INIS)

    Okada, Tomoya; Fujita, Masahiro; Shimada, Shoichi; Sato, Kohji; Schloss, Patrick; Watanabe, Yoshiyuki; Itoh, Yasushi; Tohyama, Masaya; Nishimura, Tsunehiko

    1998-01-01

    We investigated the effects of three cocaine analogs, beta-CIT (2-beta-carbomethoxy-3-beta-(4-iodophenyl)-tropane), beta-CIT-FE (2-beta-carbomethoxy-3-beta-(4-iodophenyl)-N-(2-fluoroethyl)-nortropane), and beta-CIT-FP (2-beta-carbomethoxy-3-beta-(4-iodophenyl)-N-(3-fluoropropyl)-nortropane), on the uptake of [ 3 H]dopamine(DA), serotonin(5-HT), and 1-norepinephrine (NE) using cell lines permanently expressing DA, 5-HT, and NE transporters, respectively, to determine their affinities for these three transporters. We generated cell lines stably expressing DA, 5-HT, and NE transporters, respectively, by the Chen-Okayama method, and then tested the abilities of (-)cocaine, beta-CIT, beta-CIT-FE, beta-CIT-FP, and clomipramine to inhibit the uptake of [ 3 H]DA, 5-HT, and 1-NE. Ki values of beta-CIT, beta-CIT-FE, and beta-CIT-FP for [ 3 H]DA, 5-HT, 1-NE uptake were 6, 29, and 33 nM, 91, 133, and 130 nM, and 28, 113 and 70 nM, respectively, whereas those of cocaine and clomipramine were 316, 581, and 176 nM and > 10,000, 437, and 851 nM, respectively. Beta-CIT, beta-CIT-FE, and beta-CIT-FP were shown to be potent DA, 5-HT, and NE uptake inhibitors. Beta-CIT and beta-CIT-FP were highly potent and selective dopamine uptake inhibitors, and therefore might be useful for imaging of DA transporter with single photon emission computed tomography (SPECT) or positron emission tomography (PET)

  2. Effect of water content nitrogen gross mineralization and immobilization

    International Nuclear Information System (INIS)

    Videla C, Ximena; Parada, Ana Maria; Nario M, Adriana; Pino N, Ines; Hood, Rebeca

    2005-01-01

    The decomposition of organic matter in soil, and the accompanying mineralization and immobilization of inorganic N, are key processes in the soil plant cycle. It is hypothesized that moisture regime may also play an important role on these processes. Two laboratory studies were carried out to investigate the effect of moisture regime on gross mineralization and immobilization of N, in and Ultisol soil, which was incubated at 25 o C, under two moisture regimes, field capacity (CC) (40% w/w) and 85% of field capacity (34% w/w): Using mirror image 15 N isotope dilution techniques, it was possible to determine gross nitrification and mineralization rates. The rates of gross mineralization and nitrification rate in this soil was extremely rapid and efficient, specially with 85% CC. The N transformations varied with moisture regime (author)

  3. The one-dimensional Gross-Pitaevskii equation and its some excitation states

    Energy Technology Data Exchange (ETDEWEB)

    Prayitno, T. B., E-mail: trunk-002@yahoo.com [Physics Department, Faculty of Mathematics and Natural Science, Universitas Negeri Jakarta, Jl. Pemuda Rawamangun no. 10, Jakarta, 13220 (Indonesia)

    2015-04-16

    We have derived some excitation states of the one-dimensional Gross-Pitaevskii equation coupled by the gravitational potential. The methods that we have used here are taken by pursuing the recent work of Kivshar et. al. by considering the equation as a macroscopic quantum oscillator. To obtain the states, we have made the appropriate transformation to reduce the three-dimensional Gross-Pitaevskii equation into the one-dimensional Gross-Pitaevskii equation and applying the time-independent perturbation theory in the general solution of the one-dimensional Gross-Pitaevskii equation as a linear superposition of the normalized eigenfunctions of the Schrödinger equation for the harmonic oscillator potential. Moreover, we also impose the condition by assuming that some terms in the equation should be so small in order to preserve the use of the perturbation method.

  4. Alpha-in-air monitor for continuous monitoring based on alpha to beta ratio

    International Nuclear Information System (INIS)

    Somayaji, K.S.; Venkataramani, R.; Swaminathan, N.; Pushparaja

    1997-01-01

    Measurement of long-lived alpha activity collected on a filter paper in continuous air monitoring of ambient working environment is difficult due to interference from much larger concentrations of short-lived alpha emitting daughter products of 222 Rn and 220 Rn. However, the ratio between the natural alpha and beta activity is approximately constant and this constancy of the ratio is used to discriminate against short-lived natural radioactivity in continuous air monitoring. Detection system was specially designed for the purpose of simultaneous counting of alpha and beta activity deposited on the filter paper during continuous monitoring. The activity ratios were calculated and plotted against the monitoring duration up to about six hours. Monitoring was carried out in three facilities with different ventilation conditions. Presence of any long-lived alpha contamination on the filter paper results in increase in the alpha to beta ratio. Long-lived 239 Pu contamination of about 16 DAC.h could be detected after about 45 minutes of commencement of the sampling. The experimental results using prototype units have shown that the approach of using alpha to beta activity ratio method to detect long-lived alpha activity in the presence of short-lived natural activity is satisfactory. (author)

  5. An Optimized Design of Single-Channel Beta-Gamma Coincidence Phoswich Detector by Geant4 Monte Carlo Simulations

    Directory of Open Access Journals (Sweden)

    Weihua Zhang

    2011-01-01

    Full Text Available An optimized single-channel phoswich well detector design has been proposed and assessed in order to improve beta-gamma coincidence measurement sensitivity of xenon radioisotopes. This newly designed phoswich well detector consists of a plastic beta counting cell (BC404 embedded in a CsI(Tl crystal coupled to a photomultiplier tube. The BC404 is configured in a cylindrical pipe shape to minimise light collection deterioration. The CsI(Tl crystal consists of a rectangular part and a semicylindrical scintillation part as a light reflector to increase light gathering. Compared with a PhosWatch detector, the final optimized detector geometry showed 15% improvement in the energy resolution of a 131mXe 129.4 keV conversion electron peak. The predicted beta-gamma coincidence efficiencies of xenon radioisotopes have also been improved accordingly.

  6. Measurement of some water quality parameters related to natural radionuclides in aqueous environmental samples from former tin mining lake

    International Nuclear Information System (INIS)

    Zaini Hamzah; Masitah Alias; Ahmad Saat; Abdul Kadir Ishak

    2011-01-01

    The issue of water quality is a never ended issue and becoming more critical when considering the presence of natural radionuclides. Physical parameters and the levels of radionuclides may have some correlation and need further attention. In this study, the former tin mine lake in Kampong Gajah was chosen as a study area for its past historical background which might contribute to attenuation of the levels of natural radionuclides in water. The water samples were collected from different lakes using water sampler and some in-situ measurement were conducted to measure physical parameters as well as surface dose level. The water samples were analyzed for its gross alpha and gross beta activity concentrations using liquid scintillation counting and in-house cocktail method. Gross alpha and beta analyzed using in-house cocktail are in the range of 3.17 to 8.20 Bq/ L and 9.89 to 22.20 Bq/ L; 1.64 to 8.78 Bq/ L and 0.22 to 28.22 Bq/ L, respectively for preserved and un-preserved sample. The surface dose rate measured using survey meter is in the range of 0.07 to 0.21 μSv/ h and 0.07 to 0.2 μSv/ h for surface and 1 meter above the surface of the water, respectively. (Author)

  7. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  8. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  9. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  10. Impact of season and location on the natural radioactivity in marine macroalgae (Gracilaria edulis) of coastal Tamil Nadu, India

    International Nuclear Information System (INIS)

    Saroja, P.M.; Raj, G.A.G.; Selvan, K.E.

    2012-01-01

    Gracilaria edulis, an edible red marine macro algae from three high background radiation areas (Arockiapuram, Kadiapattinam and Kurumpanai) on the southwest coast of Tamil Nadu, and one low background radiation area (Mandapam) on the southeast coast of Tamil Nadu, in India, were studied for variations in average gross alpha and beta radiation activities. Significant variations in average gross beta activities were observed while alpha activities showed only marginal variation. The average gross alpha activity was recorded high (61.51 Bq kg -1 ) during the post southwest monsoon season, while it recorded lowest (25.48 Bq kg -1 ) during the post northeast monsoon season. Average gross beta activity varied between seasons with the lowest level (211.55 Bq Kg -1 ) during post southwest monsoon season and the highest (413.33 Bq kg -1 ) during post northeast monsoon season. Among the four locations, the gross alpha activity was high (70.95 ± 26.74 Bq Kg -1 ) in Arockiapuram and low (18.74 ± 6.32 Bq Kg -1 ) in Mandapam, while the gross beta activity was high (442.25 ± 168.53 Bq Kg -1 ) in Kurumpanai and low (158.63 ± 34.37 Bq Kg -1 ) in Mandapam. Average gross alpha activity in G. edulis was found significantly varying in terms of locations, while average gross beta activity for the same species recorded significant seasonal variation. (author)

  11. Gross Motor Skills in Children With Idiopathic Clubfoot and the Association Between Gross Motor Skills, Foot Involvement, Gait, and Foot Motion.

    Science.gov (United States)

    Lööf, Elin; Andriesse, Hanneke; André, Marie; Böhm, Stephanie; Iversen, Maura D; Broström, Eva W

    2017-02-24

    Little is known regarding gross motor skills (GMS) in children with idiopathic clubfoot (IC). This study describes GMS, specifically foot involvement and asymmetries, and analyses the association between GMS, gait, and foot status in children with IC. Gross motor tasks and gait were analyzed in children with IC and typically developed (TD) children. GMS were assessed using videotapes and the Clubfoot Assessment Protocol (CAP). The Gait Deviation Index (GDI) and GDI-Kinetic were calculated from gait analyses. Children were divided into bilateral, unilateral clubfoot, or TD groups. To analyze asymmetries, feet within each group were further classified into superior or inferior foot, depending on their CAP scores. Correlations identified associations between CAP and GDI, GDI-Kinetic, passive foot motion, and Dimeglio Classification Scores at birth in the clubfeet. In total, 75 children (mean age, 5 years) were enrolled (bilateral n=22, unilateral clubfoot n=25, TD=28). Children with clubfeet demonstrated significantly lower GMS, gait, and foot motion compared with TD children. One leg standing and hopping deviated in 84% and 91%, respectively, in at least one foot in children with clubfoot. Gross motor asymmetries were evident in both children with bilateral and unilateral involvement. In children with unilateral clubfoot, contralateral feet showed few deviations in GMS compared with TD; however, differences existed in gait and foot motion. The association between GMS and gait, foot motion, and initial foot status varied between poor and moderate. Gross motor deficits and asymmetries are present in children with both bilateral and unilateral IC. Development of GMS of the contralateral foot mirrors that of TD children, but modifies to the clubfoot in gait and foot motion. The weak association with gait, foot motion, and initial clubfoot severity indicates that gross motor measurements represent a different outcome entity in clubfoot treatment. We therefore, recommend

  12. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  13. Gross Motor Skills and Cardiometabolic Risk in Children: A Mediation Analysis.

    Science.gov (United States)

    Burns, Ryan D; Brusseau, Timothy A; Fu, You; Hannon, James C

    2017-04-01

    The purpose of this study was to examine the linear relationship between gross motor skills and cardiometabolic risk, with aerobic fitness as a mediator variable, in low-income children from the United States. Participants were a convenience sample of 224 children (mean ± SD age = 9.1 ± 1.1 yr; 129 girls and 95 boys) recruited from five low-income elementary schools from the Mountain West Region of the United States. Gross motor skills were assessed using the Test for Gross Motor Development, 3rd Edition. Gross motor skills were analyzed using a locomotor skill, a ball skill, and a total gross motor skill score. Aerobic fitness was assessed using the Progressive Aerobic Cardiovascular Endurance Run that was administered during physical education class. A continuous and age- and sex-adjusted metabolic syndrome score (MetS) was calculated from health and blood marker measurements collected in a fasted state before school hours. Total effects, average direct effects, and indirect effects (average causal mediation effect) were calculated using a bootstrap mediation analysis method via a linear regression algorithm. The average causal mediation effect of gross locomotor skills on MetS scores, using aerobic fitness as the mediator variable, was statistically significant (β = -0.055, 95% confidence interval = -0.097 to -0.021, P = 0.003). The model explained approximately 17.5% of the total variance in MetS with approximately 43.7% of the relationship between locomotor skills and MetS mediated through aerobic fitness. Ball skills did not significantly relate with cardiometabolic risk. There is a significant relationship between gross locomotor skills and cardiometabolic risk that is partially mediated through aerobic fitness in a sample of low-income children from the United States.

  14. Vast Portfolio Selection with Gross-exposure Constraints().

    Science.gov (United States)

    Fan, Jianqing; Zhang, Jingjin; Yu, Ke

    2012-01-01

    We introduce the large portfolio selection using gross-exposure constraints. We show that with gross-exposure constraint the empirically selected optimal portfolios based on estimated covariance matrices have similar performance to the theoretical optimal ones and there is no error accumulation effect from estimation of vast covariance matrices. This gives theoretical justification to the empirical results in Jagannathan and Ma (2003). We also show that the no-short-sale portfolio can be improved by allowing some short positions. The applications to portfolio selection, tracking, and improvements are also addressed. The utility of our new approach is illustrated by simulation and empirical studies on the 100 Fama-French industrial portfolios and the 600 stocks randomly selected from Russell 3000.

  15. Gross Motor Profile and Its Association with Socialization Skills in Children with Autism Spectrum Disorders.

    Science.gov (United States)

    Pusponegoro, Hardiono D; Efar, Pustika; Soedjatmiko; Soebadi, Amanda; Firmansyah, Agus; Chen, Hui-Ju; Hung, Kun-Long

    2016-12-01

    While social impairment is considered to be the core deficit in children with autism spectrum disorder (ASD), a large proportion of these children have poor gross motor ability, and gross motor deficits may influence socialization skills in children with ASD. The objectives of this study were to compare gross motor skills in children with ASD to typically developing children, to describe gross motor problems in children with ASD, and to investigate associations between gross motor and socialization skills in children with ASD. This was a cross-sectional study including 40 ASD children aged from 18 months to 6 years and 40 age-matched typically developing controls. Gross motor and socialization skills were scored using the Vineland Adaptive Behavior Scales, 2 nd edition (Vineland-II). Below average gross motor function was found in eight of 40 (20%) ASD children. The mean gross motor v-scale score in the ASD group was 15.1 [standard deviation (SD) 3.12], significantly lower than in the control group [18.7, SD 2.09, p = 0.0001; 95% confidence intervals (CI) from -4.725 to -2.525]. The differences were most prominent in ball throwing and catching, using stairs, jumping, and bicycling. The ASD children with gross motor impairments had a mean socialization domain score of 66.6 (SD 6.50) compared to 85.7 (SD 10.90) in those without gross motor impairments (p = 0.0001, 95% CI from -25.327 to -12.736). Children with ASD had lower gross motor skills compared to typically developing children. Gross motor impairments were found in 20% of the ASD children, and these children also had lower socialization skills than those without gross motor impairments. Copyright © 2016. Published by Elsevier B.V.

  16. Clubfoot Does Not Impair Gross Motor Development in 5-Year-Olds.

    Science.gov (United States)

    Zapata, Karina A; Karol, Lori A; Jeans, Kelly A; Jo, Chan-Hee

    2018-04-01

    To evaluate the gross motor development of 5-year-olds using the Peabody Developmental Motor Scales, 2nd Edition (PDMS-2), test after initial nonoperative management of clubfoot as infants. The PDMS-2 Stationary, Locomotion, and Object Manipulation subtests were assessed on 128 children with idiopathic clubfeet at the age of 5 years. Children were categorized by their initial clubfoot severity as greater than 13, unilateral or bilateral involvement, and required surgery. Children with treated clubfeet had average gross motor scores (99 Gross Motor Quotient) compared with age-matched normative scores. Children with more severe clubfeet required surgery significantly more than children with less severe scores (P < .01). Peabody scores were not significantly different according to initial clubfoot severity, unilateral versus bilateral involvement, and surgical versus nonsurgical outcomes. Clubfoot does not significantly impair gross motor development in 5-year-olds.

  17. Development of a portable triple silicon detector telescope for beta spectroscopy and skin dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Helt-Hansen, J

    2000-11-01

    It is now recognized that beta radiation can be a significant radiation problem for exposure of the skin. There is thus a need for a portable and rugged active beta dosemeter-spectrometer to carry out immediate measurements of doses and energies of beta particles even in the presence of photon radiation. The main objective of this report is to describe the development of such an instrument. A beta-spectrometer has been developed consisting of three silicon surface barrier detectors with the thickness: 50{mu}m/150{mu}m/7000{mu}m covered by a 2 {mu}m thick titanium window. The spectrometer is capable of measuring electron energies from 50 keV to 3.5 MeV. The spectrometer is characterized by a compact low weight design, achieved by digital signal processing beginning at an early stage in the signal chain. 255 channels are available for each of the three detectors. The spectrometer is controlled by a laptop computer, which also handles all subsequent data analysis. By use of coincidence/anti-coincidence considerations of the absorbed energy in the three detector elements, counts caused by electrons are separated from those originating from photons. The electron energy distribution is multiplied by a set of conversion coefficients to obtain the dose at 0.07 mm tissue. Monte Carlo calculations has been used to derive the conversion coefficients and to investigate the influence of noise and the design of detector assembly on the performance of the spectrometer. This report describes the development of the spectrometer and its mode of operation, followed by a description of the Monte Carlo calculations carried out to obtain the conversion coefficients. Finally is the capability of the telescope spectrometer to measure beta and photon spectra as well as beta dose rates in pure beta and mixed beta/photon radiation fields described. (au)

  18. Development of a portable triple silicon detector telescope for beta spectroscopy and skin dosimetry

    International Nuclear Information System (INIS)

    Helt-Hansen, J.

    2000-11-01

    It is now recognized that beta radiation can be a significant radiation problem for exposure of the skin. There is thus a need for a portable and rugged active beta dosemeter-spectrometer to carry out immediate measurements of doses and energies of beta particles even in the presence of photon radiation. The main objective of this report is to describe the development of such an instrument. A beta-spectrometer has been developed consisting of three silicon surface barrier detectors with the thickness: 50μm/150μm/7000μm covered by a 2 μm thick titanium window. The spectrometer is capable of measuring electron energies from 50 keV to 3.5 MeV. The spectrometer is characterized by a compact low weight design, achieved by digital signal processing beginning at an early stage in the signal chain. 255 channels are available for each of the three detectors. The spectrometer is controlled by a laptop computer, which also handles all subsequent data analysis. By use of coincidence/anti-coincidence considerations of the absorbed energy in the three detector elements, counts caused by electrons are separated from those originating from photons. The electron energy distribution is multiplied by a set of conversion coefficients to obtain the dose at 0.07 mm tissue. Monte Carlo calculations has been used to derive the conversion coefficients and to investigate the influence of noise and the design of detector assembly on the performance of the spectrometer. This report describes the development of the spectrometer and its mode of operation, followed by a description of the Monte Carlo calculations carried out to obtain the conversion coefficients. Finally is the capability of the telescope spectrometer to measure beta and photon spectra as well as beta dose rates in pure beta and mixed beta/photon radiation fields described. (au)

  19. [Prevalence survey and molecular characterization of alpha and beta thalassemia in Liuzhou city of Guangxi].

    Science.gov (United States)

    Cai, Ren; Li, Liyan; Liang, Xin; Liu, Zhongying; Su, Liu; Li, Wenjun; Zhu, Qiangui; Mo, Qiuhua; Pan, Lizhen; Ouyang, Hong; Huang, Lihua; Xu, Xiangmin

    2002-08-01

    To investigate the gene frequencies and mutation patterns of alpha thalassemia (alpha-thal) and beta thalassemia (beta-thal) in Liuzhou city of Guangxi Zhuang Autonomous Region. Cluster sampling was used. A total of 1 028 of umbilical blood samples were collected for a prevalence study of alpha-thal and a total of 1 312 healthy young people when receiving pre-marriage consultation were recruited for a beta-thal prevalence survey. Individuals live in city or town area of Liuzhou. A complete blood count as well as hemoglobin electrophoresis analysis were done in all of samples for phenotyping of alpha and beta-thals. Those with Hb Bart's for alpha-thal indicator and those with both microcytosis (MCV /=4.0%) for beta-thal were further studied by DNA analysis. PCR-based methodologies were used to characterize the mutation contributions of alpha and beta-thals. All the subjects were tested for the state of carrying beta-thala alleles for evaluating the situation of the compound heterozygotes of alpha-thal with beta-thal. Of 1 028 random samples of umbilical blood screened, 112 of subjects were defined to be the gene carriers of alpha-thal. The alpha-thal carrier rate was as high as 11.19% including 3 compound heterozygotes. Five well-known types of alpha-thal alleles were detected with gene contributions of 37.4% (--(SEA) deletion), 31.3% (-alpha(3.7) deletion), 17.4% (-alpha(4.2) deletion), 12.1% (alpha(CS)alpha mutation), and 0.9% (alpha(QS)alpha mutation), successively. Of the 1 312 adult specimens studied, 89 with beta-thal including 14 of the compound higher Hb F subjects were detected. All of the 89 phenotypic beta-thal carriers had the mutations in the beta-globin gene, making the overall prevalence 6.78%. The commonly seen three mutations, beta CD41 - 42 (-CTTT) frameshift, beta CD17 (T-A) nonsense mutation and beta-28 (A-G) promoter variation were accounted for 90% of the beta-thal alleles in Liuzhou. Of these beta-thal subjects, 16 (accounting for 18%) were

  20. Integrability of the Gross-Pitaevskii equation with Feshbach resonance management

    International Nuclear Information System (INIS)

    Zhao Dun; Luo Honggang; Chai Huayue

    2008-01-01

    In this Letter we study the integrability of a class of Gross-Pitaevskii equations managed by Feshbach resonance in an expulsive parabolic external potential. By using WTC test, we find a condition under which the Gross-Pitaevskii equation is completely integrable. Under the present model, this integrability condition is completely consistent with that proposed by Serkin, Hasegawa, and Belyaeva [V.N. Serkin, A. Hasegawa, T.L. Belyaeva, Phys. Rev. Lett. 98 (2007) 074102]. Furthermore, this integrability can also be explicitly shown by a transformation, which can convert the Gross-Pitaevskii equation into the well-known standard nonlinear Schroedinger equation. By this transformation, each exact solution of the standard nonlinear Schroedinger equation can be converted into that of the Gross-Pitaevskii equation, which builds a systematical connection between the canonical solitons and the so-called nonautonomous ones. The finding of this transformation has a significant contribution to understanding the essential properties of the nonautonomous solitons and the dynamics of the Bose-Einstein condensates by using the Feshbach resonance technique

  1. School Physical Activity Programming and Gross Motor Skills in Children.

    Science.gov (United States)

    Burns, Ryan D; Fu, You; Hannon, James C; Brusseau, Timothy A

    2017-09-01

    We examined the effect of a comprehensive school physical activity program (CSPAP) on gross motor skills in children. Participants were 959 children (1st-6th grade; Mean age = 9.1 ± 1.5 years; 406 girls, 553 boys) recruited from 5 low-income schools receiving a year-long CSPAP intervention. Data were collected at the beginning of the school year and at a 36-week follow-up. Gross motor skills were assessed using the Test for Gross Motor Development (3rd ed.) (TGMD-3) instrument. Multi-level mixed effects models were employed to examine the effect of CSPAP on TGMD-3 scores, testing age and sex as effect modifiers and adjusting for clustering of observations within the data structure. There were statistically significant coefficients for time (β = 8.1, 95% CI [3.9, 12.3], p skills and ball skills sub-test scores. Children showed improved gross motor skill scores at the end of the 36-week CSPAP that were modified by age, as younger children displayed greater improvements in TGMD-3 scores compared to older children.

  2. Measurement of the two-neutrino double-beta decay half-life of {sup 130}Te with the CUORE-0 experiment

    Energy Technology Data Exchange (ETDEWEB)

    Alduino, C.; Avignone, F.T.; Chott, N.; Creswick, R.J.; Rosenfeld, C.; Wilson, J. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); Alfonso, K.; Hickerson, K.P.; Huang, H.Z.; Liu, X.; Trentalange, S.; Zhu, B.X. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Artusa, D.R. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Azzolini, O.; Camacho, A.; Keppel, G.; Palmieri, V.; Pira, C. [INFN-Laboratori Nazionali di Legnaro, Legnaro, Padova (Italy); Banks, T.I.; Drobizhev, A.; Freedman, S.J.; Hennings-Yeomans, R.; O' Donnell, T.; Wagaarachchi, S.L. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Bari, G.; Deninno, M.M. [INFN-Sezione di Bologna, Bologna (Italy); Beeman, J.W. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); Bellini, F.; Cardani, L.; Casali, N.; Cosmelli, C.; Ferroni, F. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Bersani, A.; Caminata, A. [INFN-Sezione di Genova, Genova (Italy); Biassoni, M.; Carbone, L.; Cremonesi, O.; Ferri, E.; Giachero, A.; Pessina, G.; Previtali, E.; Rusconi, C. [INFN-Sezione di Milano Bicocca, Milan (Italy); Brofferio, C.; Capelli, S.; Carniti, P.; Cassina, L.; Chiesa, D.; Clemenza, M.; Faverzani, M.; Fiorini, E.; Gironi, L.; Gotti, C.; Maino, M.; Nucciotti, A.; Pavan, M.; Pozzi, S.; Sisti, M.; Terranova, F.; Zanotti, L. [Universita di Milano-Bicocca, Dipartimento di Fisica, Milan (Italy); INFN-Sezione di Milano Bicocca, Milan (Italy); Bucci, C.; Cappelli, L.; D' Addabbo, A.; Di Vacri, M.L.; Gorla, P.; Pattavina, L.; Pirro, S. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Canonica, L. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Massachusetts Institute of Technology, Cambridge, MA (United States); Cao, X.G.; Fang, D.Q.; Ma, Y.G.; Wang, H.W.; Zhang, G.Q. [Chinese Academy of Sciences, Shanghai Institute of Applied Physics, Shanghai (China); Copello, S.; Di Domizio, S.; Fernandes, G.; Marini, L.; Pallavicini, M. [INFN-Sezione di Genova, Genova (Italy); Universita di Genova, Dipartimento di Fisica, Genova (Italy); Cushman, J.S.; Davis, C.J.; Heeger, K.M.; Lim, K.E.; Maruyama, R.H. [Yale University, Department of Physics, New Haven, CT (United States); Dafinei, I.; Morganti, S.; Mosteiro, P.J.; Orio, F.; Pettinacci, V.; Tomei, C.; Vignati, M. [INFN-Sezione di Roma, Rome (Italy); Dell' Oro, S. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); INFN-Gran Sasso Science Institute, L' Aquila (Italy); Feintzeig, J.; Fujikawa, B.K.; Mei, Y.; Smith, A.R. [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Franceschi, M.A.; Ligi, C.; Napolitano, T.; Piperno, G. [INFN-Laboratori Nazionali di Frascati, Frascati, Rome (Italy); Giuliani, A.; Tenconi, M. [Universite Paris-Saclay, CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Orsay (France); Gladstone, L.; Leder, A.; Winslow, L.A. [Massachusetts Institute of Technology, Cambridge, MA (United States); Gutierrez, T.D. [California Polytechnic State University, Physics Department, San Luis Obispo, CA (United States); Haller, E.E. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); University of California, Department of Materials Science and Engineering, Berkeley, CA (United States); Han, K. [Yale University, Department of Physics, New Haven, CT (United States); Shanghai Jiao Tong University, Department of Physics and Astronomy, Shanghai (China); Hansen, E. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Massachusetts Institute of Technology, Cambridge, MA (United States); Kadel, R. [Lawrence Berkeley National Laboratory, Physics Division, Berkeley, CA (United States); Kolomensky, Yu.G. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Physics Division, Berkeley, CA (United States); Martinez, M. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Universidad de Zaragoza, Laboratorio de Fisica Nuclear y Astroparticulas, Zaragoza (Spain); Moggi, N. [INFN-Sezione di Bologna, Bologna (Italy); Alma Mater Studiorum-Universita di Bologna, Dipartimento di Scienze per la Qualita della Vita, Bologna (Italy); Nones, C. [Service de Physique des Particules, CEA/Saclay, Gif-sur-Yvette (France); Norman, E.B.; Wang, B.S. [Lawrence Livermore National Laboratory, Livermore, CA (United States); University of California, Department of Nuclear Engineering, Berkeley, CA (United States); Ouellet, J.L. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Massachusetts Institute of Technology, Cambridge, MA (United States); Pagliarone, C.E. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Universita degli Studi di Cassino e del Lazio Meridionale, Dipartimento di Ingegneria Civile e Meccanica, Cassino (Italy); Sangiorgio, S.; Scielzo, N.D. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Santone, D. [INFN-Laboratori Nazionali del Gran Sasso, Assergi, L' Aquila (Italy); Universita dell' Aquila, Dipartimento di Scienze Fisiche e Chimiche, L' Aquila (Italy); Singh, V. [University of California, Department of Physics, Berkeley, CA (US); Taffarello, L. [INFN-Sezione di Padova, Padova (IT); Wise, T. [Yale University, Department of Physics, New Haven, CT (US); University of Wisconsin, Department of Physics, Madison, WI (US); Woodcraft, A. [University of Edinburgh, SUPA, Institute for Astronomy, Edinburgh (GB); Zimmermann, S. [Lawrence Berkeley National Laboratory, Engineering Division, Berkeley, CA (US); Zucchelli, S. [INFN-Sezione di Bologna, Bologna (IT); Alma Mater Studiorum-Universita di Bologna, Dipartimento di Fisica e Astronomia, Bologna (IT)

    2017-01-15

    We report on the measurement of the two-neutrino double-beta decay half-life of {sup 130}Te with the CUORE-0 detector. From an exposure of 33.4 kg year of TeO{sub 2}, the half-life is determined to be T{sub 1/2}{sup 2ν} = [8.2 ± 0.2 (stat.) ± 0.6 (syst.)] x 10{sup 20} year. This result is obtained after a detailed reconstruction of the sources responsible for the CUORE-0 counting rate, with a specific study of those contributing to the {sup 130}Te neutrinoless double-beta decay region of interest. (orig.)

  3. Biosynthesis and release of beta-endorphin-, N-acetyl beta-endorphin-, beta-endorphin-(1-27)-, and N-acetyl beta-endorphin-(1-27)-like peptides by rat pituitary neurointermediate lobe: beta-endorphin is not further processed by anterior lobe

    International Nuclear Information System (INIS)

    Liotta, A.S.; Yamaguchi, H.; Krieger, D.T.

    1981-01-01

    Continuous labeling and pulse-chase techniques were employed to study the synthesis and secretion of multiple forms of immunoreactive beta-endorphin by cultured dispersed rat anterior lobe cells and intact neurointermediate pituitary lobe. Intact neurointermediate lobes incorporated radiolabeled amino acids into four to six forms of immunoreactive beta-endorphin. Four of these forms were physicochemically similar to authentic beta-endorphin, N-acetylated beta-endorphin, beta-endorphin-(1-27), and N-acetylated beta-endorphin-(1-27). Pulse-chase studies indicated that a beta-lipotropin-like molecule served as a metabolic intermediate for a beta-endorphin-like molecule. As beta-endorphin-like material accumulated in the cell, some of it was N-acetylated (approximately 18% at 2 hr chase and approximately 65% at 18 hr chase). At later chase times, beta-endorphin-(1-27)- and N-acetylated beta-endorphin-(1-27)-like peptides were the predominant molecular species detected. All endorphin forms were detected in unlabeled tissue maintained in culture or tissue continuously labeled for 72 hr and were released into the medium under basal, stimulatory (10(-8) M norepinephrine), or inhibitory (10(-7) M dopamine) incubation conditions. In all cases, beta-endorphin-(1-27)-like species were the predominant forms (more than 70% of total) present in the cells and released into the medium. In contrast, approximately 90% of radiolabeled immunoreactive beta-endorphin extracted from anterior lobe cells and medium similarly incubated appeared to represent the authentic beta-endorphin molecule. Continuous labeling (72 hr) revealed the beta-lipotropin/beta-endorphin molar ratio to be approximately 4. We conclude that, in anterior lobe, most of the beta-endorphin is not processed further and is released intact, while in neurointermediate lobe, it serves as a biosynthetic intermediate

  4. Influence of surface active agents on the detection of beta radiation

    International Nuclear Information System (INIS)

    Mesquita, T.B.; Ruegg, E.F.

    1984-01-01

    It has been studied the efficiency of beta irradiation detection by liquid scintillation counting using the pesticide 14 C-lindane as radiation source and scientillation cocktails containing Triton-X, Arkopal, Tinoventin, Extravon-200, Oswalmida, Bigral, ethanol and methanol. Excepting the last 5 products, which led to a phase formation in the mixture, all other compounds, that are easily available in the local market, proved to be good substitute products for the well known Triton-X, an expensive and restrict emulsifier used for liquid scintillation measurement of aqueous solutions. (Author) [pt

  5. Gross motor skill development of 5-year-old Kindergarten children in Myanmar.

    Science.gov (United States)

    Aye, Thanda; Oo, Khin Saw; Khin, Myo Thuzar; Kuramoto-Ahuja, Tsugumi; Maruyama, Hitoshi

    2017-10-01

    [Purpose] The purpose of this study was to examine the gross motor skill development of 5-year-old Kindergarten children in Myanmar. [Subjects and Methods] Total 472 healthy Kindergarten children (237 males, 235 females) of 2016-2017 academic year from four schools in urban area and four schools in rural area of Myanmar were recruited. The gross motor skill development of all subjects was assessed with the test of gross motor development second edition (TGMD-2). All subjects performed two trials for each gross motor skill and the performance was video recorded and scored. The assessment procedures were done according to the standardized guidelines of TGMD-2. [Results] The majority of subjects had average level of gross motor skill rank. The significant differences were found on the run and gallop of locomotor skills and the most of object control skills except the catch between males and females. The significant differences were also found between subjects from urban and rural areas. [Conclusion] Gross motor skill development of 5-year-old Kindergarten children in Myanmar had gender-based and region-based differences on both locomotor and object control skills. This study added a valuable information to the establishment of a normative reference of Kindergarten aged children for future studies.

  6. Primary 4{pi}{beta}-{gamma} coincidence system for standardization of radionuclides by means of plastic scintillators; Sistema primario por coincidencias 4{pi}{beta}-{gamma} para a padronizacao de radionuclideos empregando cintiladores plasticos

    Energy Technology Data Exchange (ETDEWEB)

    Baccarelli, Aida Maria

    2003-07-01

    The present work describes a 4{pi}({alpha},{beta})-{gamma} coincidence system for absolute measurement of radionuclide activity using a plastic scintillator in 4{pi} geometry for charged particles detection and a Nal (Tl) crystal for gamma-ray detection. Several shapes and dimensions of the plastic scintillator have been tried in order to obtain the best system configuration. Radionuclides which decay by alpha emission, {beta}{sup -}, {beta}{sup +} and electron capture have been standardized. The results showed excellent agreement with other conventional primary system which makes use of a 4{pi} proportional counter for X-ray and charged particle detection. The system developed in the present work have some advantages when compared with the conventional systems, namely; it does not need metal coating on the films used as radioactive source holders. When compared to liquid scintillators, is showed the advantage of not needing to be kept in dark for more than 24 h to allow phosphorescence decay of ambient light. Therefore it can be set to count immediately after the sources are placed inside of it. (author)

  7. FXIIIA and TGF-beta over-expression produces normal musculo-skeletal phenotype in TG2-/- mice.

    Science.gov (United States)

    Tarantino, U; Oliva, F; Taurisano, G; Orlandi, A; Pietroni, V; Candi, E; Melino, G; Maffulli, N

    2009-04-01

    Transglutaminase (TGs) enzymes and proteins crosslinking have for long time been implicated in the formation of hard tissue development, matrix maturation and mineralization. Among the TGs family members, in the context of connective tissue formation, TG2 and Factor XIII are expressed in cartilage by hypertrophic chondrocytes. Here, we analyse the morphological consequences of TG2 deficiency, during the development of skeletal elements. When TG2 is absent, there are not gross abnormalities in the development of the skeletal system, probably from compensatory mechanisms resulting in increased expression of FXIIIA and TGF-beta 1. In vivo other TGs may be involved in promoting chondrocytes and osteoblast differentiation and matrix mineralisation.

  8. Beta-thalassaemia trait: haematological parameters

    International Nuclear Information System (INIS)

    Yousafzai, Y.M.; Khan, S.; Raziq, F.

    2010-01-01

    Thalassaemia syndromes are a group of hereditary disorders characterised by a genetic deficiency in the synthesis of --globin genes. The objective of this study was to determine the haematological features -thalassaemia trait (BTT), and to determine the sensitivity of Mean Corpuscular Volume (MCV), Mean Corpuscular Haemoglobin (MCH) and -thalassaemia trait. Methods: A descriptive study was conducted in Hayatabad Medical Complex, Peshawar from May 2009 to May 2010 with 203 subjects having BTT. Blood samples were collected in EDTA anti-coagulated tubes. RBC indices were taken as part of complete blood count (CBC) by haematology analyser, and Haemoglobin (Hb) electrophoresis was done to determine the HbA2 percentage. The data was collected and analyzed on statistical software for demographic details, RBC indices and HBA2 levels. Results: Out of 203 patients, 92 (45%) were males and 111 (55%) were females. Most patients tested were in the 15-45 year age group. One-hundred-sixty (79%) patients had anaemia. MCV was lower than 76 fl in all the cases. Mean MCV was 59.1 fl. MCH was low, the mean MCH being 19.3 g/dl. MCH <26 gave sensitivity of 99% in detecting BTT. We calculated MI for these cases and found out that it was <12 in 75% of cases and <15 in 197 (97%). Conclusion: Beta-thalassaemia traits present with a microcytic hypochromic blood picture, detected on simple haematology analysers as low MCV and MCH and MI which provide a beta- thalassaemia trait. (author)

  9. Results from the preliminary conveyor evaluation of the high-energy beta scintillation sensor at the Fernald Soil Decontamination Pilot Plant

    International Nuclear Information System (INIS)

    Schilk, A.J.; Knopf, M.A.

    1994-07-01

    W tested a high-energy beta scintillation sensor to evaluate its efficacy in continually characterizing washed soils moving on a conveyor belt at Fernald's Soil Decontamination Pilot Plant (SDPP). This sensor was originally developed for monitoring uranium-contaminated soils in the field. It has a multi-layer design that enables it to discriminate against lower-energy beta particles from natural sources. It can also distinguish, to some extent, gamma rays and cosmic-induced species. The sensor detects uranium activity indirectly, based on the assumption that secular equilibrium exists between the targeted radionuclide ( 234m Pa) and its parent ( 238 U). Several 1-h background counts were made at the SDPP each day of the evaluation period. The average background count rate was found to be comparable to that observed under previous laboratory conditions. Static runs were performed on soils from SDPP test runs No. 1 and No. 17 to determine the extent of any residual activity following the decontamination process. Soils were found to contain 158±30 pCi/g and 114±25 pCi/g of 234 Th- 234m Pa ( 238 U?), respectively. But the soils had considerable moisture, and concern existed that this moisture would act as an additional beta attenuator and thereby give results that were erroneously low. Therefore, a soil sample was baked overnight, and the hard-baked clay that resulted was ground into small fragments and counted. This sample was counted for 30 min as before, and the total activity was determined to be 313±44 pCi/g of 234 Th 234m Pa ( 238 U?). Based on the test No. 1 results, a dry-to-wet activity ratio of 1.98 has been established. Hence, if the moisture content of test No. 17 was equivalent to that of test No. 1, the actual 234 Th- 234m Pa ( 238 U?) activity level is expected to be approximately 226 pCi/g

  10. 46 CFR 167.01-8 - Inspection of school ships using gross tonnage criterion.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Inspection of school ships using gross tonnage criterion... SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS General Provisions § 167.01-8 Inspection of school ships using gross... school ships by relative sizes in gross tonnages. When it is determined in accordance with § 70.05-20 of...

  11. Gross and microscopic lesions in corals from Micronesia

    Science.gov (United States)

    Work, Thierry M.; Aeby, Greta S.; Hughen, Konrad A.

    2015-01-01

    The authors documented gross and microscopic morphology of lesions in corals on 7 islands spanning western, southern, and eastern Micronesia, sampling 76 colonies comprising 30 species of corals among 18 genera, with Acropora, Porites, and Montipora dominating. Tissue loss comprised the majority of gross lesions sampled (41%), followed by discoloration (30%) and growth anomaly (29%). Of 31 cases of tissue loss, most lesions were subacute (48%), followed by acute and chronic (26% each). Of 23 samples with discoloration, most were dark discoloration (40%), with bleaching and other discoloration each constituting 30%. Of 22 growth anomalies, umbonate growth anomalies composed half, with exophytic, nodular, and rugose growth anomalies composing the remainder. On histopathology, for 9 cases of dark discoloration, fungal infections predominated (77%); for 7 bleached corals, depletion of zooxanthellae from the gastrodermis made up a majority of microscopic diagnoses (57%); and for growth anomalies other than umbonate, hyperplasia of the basal body wall was the most common microscopic finding (63%). For the remainder of the gross lesions, no single microscopic finding constituted >50% of the total. Host response varied with the agent present on histology. Fragmentation of tissues was most often associated with algae (60%), whereas necrosis dominated (53%) for fungi. Two newly documented potentially symbiotic tissue-associated metazoans were seen in Porites and Montipora. Findings of multiple potential etiologies for a given gross lesion highlight the importance of incorporating histopathology in coral disease surveys. This study also expands the range of corals infected with cell-associated microbial aggregates.

  12. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  13. Gross Motor Profile and Its Association with Socialization Skills in Children with Autism Spectrum Disorders

    OpenAIRE

    Hardiono D. Pusponegoro; Pustika Efar; Soedjatmiko; Amanda Soebadi; Agus Firmansyah; Hui-Ju Chen; Kun-Long Hung

    2016-01-01

    While social impairment is considered to be the core deficit in children with autism spectrum disorder (ASD), a large proportion of these children have poor gross motor ability, and gross motor deficits may influence socialization skills in children with ASD. The objectives of this study were to compare gross motor skills in children with ASD to typically developing children, to describe gross motor problems in children with ASD, and to investigate associations between gross motor and sociali...

  14. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  15. Vast Portfolio Selection with Gross-exposure Constraints*

    Science.gov (United States)

    Fan, Jianqing; Zhang, Jingjin; Yu, Ke

    2012-01-01

    We introduce the large portfolio selection using gross-exposure constraints. We show that with gross-exposure constraint the empirically selected optimal portfolios based on estimated covariance matrices have similar performance to the theoretical optimal ones and there is no error accumulation effect from estimation of vast covariance matrices. This gives theoretical justification to the empirical results in Jagannathan and Ma (2003). We also show that the no-short-sale portfolio can be improved by allowing some short positions. The applications to portfolio selection, tracking, and improvements are also addressed. The utility of our new approach is illustrated by simulation and empirical studies on the 100 Fama-French industrial portfolios and the 600 stocks randomly selected from Russell 3000. PMID:23293404

  16. Measurement of Radon-Induced Backgrounds in the NEXT Double Beta Decay Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Novella, P.; et al.

    2018-04-02

    The measurement of the internal 222Rn activity in the NEXT-White detector during the so-called Run-II period with 136Xe-depleted xenon is discussed in detail, together with its implications for double beta decay searches in NEXT. The activity is measured through the alpha production rate induced in the fiducial volume by 222Rn and its alpha-emitting progeny. The specific activity is measured to be $(37.5\\pm 2.3~\\mathrm{(stat.)}\\pm 5.9~\\mathrm{(syst.)})$~mBq/m$^3$. Radon-induced electrons have also been characterized from the decay of the 214Bi daughter ions plating out on the cathode of the time projection chamber. From our studies, we conclude that radon-induced backgrounds are sufficiently low to enable a successful NEXT-100 physics program, as the projected rate contribution should not exceed 0.2~counts/yr in the neutrinoless double beta decay sample.

  17. Purification of beta-acetylglucosaminase and beta-galactosidase from ram testis.

    Science.gov (United States)

    Caygill, J C; Roston, C P; Jevons, F R

    1966-02-01

    1. The presence of beta-galactosidase (EC 3.2.1.23) in an acetic acid extract of ram testis is reported. Some properties of the crude enzyme preparation were studied. 2. The purification of beta-acetylglucosaminase (EC 3.2.1.30) and of beta-galactosidase from the ram-testis extract by ammonium sulphate precipitation and chromatography on a CM-cellulose column is described. 3. The final purifications of the separated enzymes achieved were for the beta-acetylglucosaminase 35 times and for the beta-galactosidase 99 times. 4. The possibility of using DEAE-cellulose and Sephadex G-200 to purify the enzymes was investigated.

  18. Standardisation of 64Cu using a software coincidence counting system

    International Nuclear Information System (INIS)

    Havelka, Miroslav; Sochorová, Jana

    2014-01-01

    The activity of the radionuclide 64 Cu was determined by the efficiency extrapolation method applied to 4π(PC)−γ coincidence counting. The standardisation was performed by software coincidence counting—a digital method for primary activity measurement that simplifies the setting of optimal coincidence parameters. The γ-ray-energy window, characterised by identical gamma detection efficiency related to the sum of EC and to the sum of beta decay branches, was found. This setting ensured a linear and zero slope extrapolation curve. - Highlights: • Standardisation realised by extrapolation method applied to 4π(PC)−γ coincidence. • Digital method for optimal setting of coincidence parameters was used. • Result with total standard uncertainty of 0.74% was obtained

  19. Pb-210 behaviour in environmental samples from the Cuban east in 1993

    International Nuclear Information System (INIS)

    Perez Tamayo, L.; Suarez Pina, W.

    1996-01-01

    A method based in alpha and beta gross counting, is applied to research behaviour, during 1993, of Pb-210 in atmospheric depositional samples of six sites of the Cuban east. In five of these points, located distant from Cuban centers, the average Pb-210 aport to measured beta activity is predominant (80 +- 20 %) and maximum (> 50 % annual) is observed in coincidence with the first rain full peak. Such regularity may be explained, if assumption is made that principal source of Pb-210 are the continental air masses penetrating the insular atmosphere in winter and that mentioned radionuclide is deposit later with the spring rainfalls. In the sixth point, located at industrial zone, the alpha-beta activities rates are abnormally high, with maximums of 1.5 and 2.4 faced with peak raining and wet months respectively and probably originated by the input atmosphere of rich s in alpha emisors particles from industrial processes

  20. Pb-210 behaviour in environmental samples from the Cuban East in 1993

    International Nuclear Information System (INIS)

    Perez T, L.; Suarez P, W.

    1996-01-01

    Purely experimental method based on the alpha and beta gross counting is applied to determine Pb-210 behaviour in deposition samples from six points of the eastern part of Cuba during 1993. The results were similar in the five points away from the crowded inhabited centers: an evident Pb-210 maximum (more than 50% annual) coinciding with the higher rainy trimester in spring and the contribution of the mentioned radionuclide to the 80-100% of the total deposited beta activity. In the sixth point, located in an industrial zone, alpha and beta activity relations are abnormally high (1.5-3.0) and present peaks in the rainiest and driest months. Hypothesis are formulated to explain these results, which are related to the cyclic input of cool continental air masses rich in radon and its daughters to the island atmosphere in the first case and with input to atmosphere of particles rich in alpha-emitters of industrial origin in the record case. (authors). 3 refs

  1. Betting Against Beta

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Heje Pedersen, Lasse

    We present a model with leverage and margin constraints that vary across investors and time. We find evidence consistent with each of the model’s five central predictions: (1) Since constrained investors bid up high-beta assets, high beta is associated with low alpha, as we find empirically for U...... of the BAB factor is low; (4) Increased funding liquidity risk compresses betas toward one; (5) More constrained investors hold riskier assets........S. equities, 20 international equity markets, Treasury bonds, corporate bonds, and futures; (2) A betting-against-beta (BAB) factor, which is long leveraged low beta assets and short high-beta assets, produces significant positive risk-adjusted returns; (3) When funding constraints tighten, the return...

  2. Removal of radionuclides in drinking water by membrane treatment using ultrafiltration, reverse osmosis and electrodialysis reversal.

    Science.gov (United States)

    Montaña, M; Camacho, A; Serrano, I; Devesa, R; Matia, L; Vallés, I

    2013-11-01

    A pilot plant had been built to test the behaviour of ultrafiltration (UF), reverse osmosis (RO), and electrodialysis reversal (EDR) in order to improve the quality of the water supplied to Barcelona metropolitan area from the Llobregat River. This paper presents results from two studies to reduce natural radioactivity. The results from the pilot plant with four different scenarios were used to design the full-scale treatment plant built (SJD WTP). The samples taken at different steps of the treatment were analysed to determine gross alpha, gross beta and uranium activity. The results obtained revealed a significant improvement in the radiological water quality provided by both membrane techniques (RO and EDR showed removal rates higher than 60%). However, UF did not show any significant removal capacity for gross alpha, gross beta or uranium activities. RO was better at reducing the radiological parameters studied and this treatment was selected and applied at the full scale treatment plant. The RO treatment used at the SJD WTP reduced the concentration of both gross alpha and gross beta activities and also produced water of high quality with an average removal of 95% for gross alpha activity and almost 93% for gross beta activity at the treatment plant. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Conversion of beta-methylbutyric acid to beta-hydroxy-beta-methylbutyric acid by Galactomyces reessii.

    OpenAIRE

    Lee, I Y; Nissen, S L; Rosazza, J P

    1997-01-01

    beta-Hydroxy-beta-methylbutyric acid (HMB) has been shown to increase strength and lean mass gains in humans undergoing resistance-exercise training. HMB is currently marketed as a calcium salt of HMB, and thus, environmentally sound and inexpensive methods of manufacture are being sought. This study investigates the microbial conversion of beta-methylbutyric acid (MBA) to HMB by cultures of Galactomyces reessii. Optimal concentrations of MBA were in the range of 5 to 20 g/liter for HMB produ...

  4. The relationship between gross motor skills and academic achievement in children with learning disabilities

    NARCIS (Netherlands)

    Westendorp, Marieke; Hartman, Esther; Houwen, Suzanne; Smith, Joanne; Visscher, Chris

    2011-01-01

    The present study compared the gross motor skills of 7- to 12-year-old children with learning disabilities (n = 104) with those of age-matched typically developing children (n = 104) using the Test of Gross Motor Development-2. Additionally, the specific relationships between subsets of gross motor

  5. Production of beta-glucosidase and hydrolysis of isoflavone phytoestrogens by Lactobacillus acidophilus, Bifidobacterium lactis, and Lactobacillus casei in soymilk.

    Science.gov (United States)

    Donkor, O N; Shah, N P

    2008-01-01

    The study determined beta-glucosidase activity of commercial probiotic organisms for hydrolysis of isoflavone to aglycones in fermenting soymilk. Soymilk made with soy protein isolate (SPI) was fermented with Lactobacillus acidophilus LAFTI L10, Bifidobacterium lactis LAFTI B94, and Lactobacillus casei LAFTI L26 at 37 degrees C for 48 h and the fermented soymilk was stored for 28 d at 4 degrees C. beta-Glucosidase activity of organisms was determined using rho-nitrophenyl beta-D-glucopyranoside as a substrate and the hydrolysis of isoflavone glycosides to aglycones by these organisms was carried out. The highest level of growth occurred at 12 h for L. casei L26, 24 h for B. lactis B94, and 36 h for L. acidophilus L10 during fermentation in soymilk. Survival after storage at 4 degrees C for 28 d was 20%, 15%, and 11% greater (P < 0.05) than initial cell counts, respectively. All the bacteria produced beta-glucosidase, which hydrolyzed isoflavone beta-glycosides to isoflavone aglycones. The decrease in the concentration of beta-glycosides and the increase in the concentration of aglycones were significant (P < 0.05) in the fermented soymilk. Increased isoflavone aglycone content in fermented soymilk is likely to improve the biological functionality of soymilk.

  6. Forward-Looking Betas

    DEFF Research Database (Denmark)

    Christoffersen, Peter; Jacobs, Kris; Vainberg, Gregory

    Few issues are more important for finance practice than the computation of market betas. Existing approaches compute market betas using historical data. While these approaches differ in terms of statistical sophistication and the modeling of the time-variation in the betas, they are all backward......-looking. This paper introduces a radically different approach to estimating market betas. Using the tools in Bakshi and Madan (2000) and Bakshi, Kapadia and Madan (2003) we employ the information embedded in the prices of individual stock options and index options to compute our forward-looking market beta...

  7. Use of the Beta-Binomial Model for Central Statistical Monitoring of Multicenter Clinical Trials

    OpenAIRE

    Desmet, Lieven; Venet, David; Doffagne, Erik; Timmermans, Catherine; Legrand, Catherine; Burzykowski, Tomasz; Buyse, Marc

    2017-01-01

    As part of central statistical monitoring of multicenter clinical trial data, we propose a procedure based on the beta-binomial distribution for the detection of centers with atypical values for the probability of some event. The procedure makes no assumptions about the typical event proportion and uses the event counts from all centers to derive a reference model. The procedure is shown through simulations to have high sensitivity and high specificity if the contamination rate is small and t...

  8. Criteria for requesting specific radionuclide analysis through gross α and gross β concentration measurements in environmental samples

    International Nuclear Information System (INIS)

    Ferreira, E.G.

    1988-01-01

    This paper suggests some criteria for the decision to proceed with the analysis of specific radionuclides based on results of the determination of gross α and β concentrations in environmental samples of aerosols, water, dairy and agricultural products, soil and sediments. The samples considered are provenient from the environmental surveillance of uranium mining and milling facilities as well as the mining and processing plants of monazite sands. The radionuclides to be analysed are those considered to be the most critical to human health, that is: U-nat; Th-nat; Th-230; Ra-228; Ra-226; Po-210; Pb-210. The measured gross α and β concentrations will be compared with the Maximum Allowable Concentrations for some defined radionuclides. Radiochemical analysis of specific radionuclides may then become necessary, depending upon the results of this comparison. The main goal of the proposed guide is to simplify and to discipline the execution of environmental surveillance programs in a safe and economical way, avoiding unnecessary analysis. (author) [pt

  9. A global assessment of gross and net land change dynamics for current conditions and future scenarios

    Science.gov (United States)

    Fuchs, Richard; Prestele, Reinhard; Verburg, Peter H.

    2018-05-01

    The consideration of gross land changes, meaning all area gains and losses within a pixel or administrative unit (e.g. country), plays an essential role in the estimation of total land changes. Gross land changes affect the magnitude of total land changes, which feeds back to the attribution of biogeochemical and biophysical processes related to climate change in Earth system models. Global empirical studies on gross land changes are currently lacking. Whilst the relevance of gross changes for global change has been indicated in the literature, it is not accounted for in future land change scenarios. In this study, we extract gross and net land change dynamics from large-scale and high-resolution (30-100 m) remote sensing products to create a new global gross and net change dataset. Subsequently, we developed an approach to integrate our empirically derived gross and net changes with the results of future simulation models by accounting for the gross and net change addressed by the land use model and the gross and net change that is below the resolution of modelling. Based on our empirical data, we found that gross land change within 0.5° grid cells was substantially larger than net changes in all parts of the world. As 0.5° grid cells are a standard resolution of Earth system models, this leads to an underestimation of the amount of change. This finding contradicts earlier studies, which assumed gross land changes to appear in shifting cultivation areas only. Applied in a future scenario, the consideration of gross land changes led to approximately 50 % more land changes globally compared to a net land change representation. Gross land changes were most important in heterogeneous land systems with multiple land uses (e.g. shifting cultivation, smallholder farming, and agro-forestry systems). Moreover, the importance of gross changes decreased over time due to further polarization and intensification of land use. Our results serve as an empirical database for

  10. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  11. Gross xenon stability

    International Nuclear Information System (INIS)

    Lewins, J.D.; Wilson, P.P.H.

    1997-01-01

    The effect of xenon in thermal reactors on steady operation is generally destabilizing. Illustrating this involves the study of appropriate transfer functions, which may be conveniently displayed in three ways: as Bode, Nyquist, and root-locus diagrams. The three forms allow different aspects to be highlighted. These are illustrated for the effect of xenon with allowance not only for the stabilizing effect of the direct yield in fission but also to show the consequences of neglecting the time dependence due to the thermal capacity of the reactor. With careful interpretation, all these forms give an interpretation of stability that is consistent with direct evaluation and promote the understanding of the onset of gross oscillations in power

  12. Enantioselective synthesis of alpha,beta-disubstituted-beta-amino acids.

    Science.gov (United States)

    Sibi, Mukund P; Prabagaran, Narayanasamy; Ghorpade, Sandeep G; Jasperse, Craig P

    2003-10-01

    Highly diastereoselective and enantioselective addition of N-benzylhydroxylamine to imides 17 and 20-30 produces alpha,beta-trans-disubstituted N-benzylisoxazolidinones 19 and 31-41. These reactions proceed in 60-96% ee with 93-99% de's using 5 mol % of Mg(NTf2)2 and ligand 18. The product isoxazolidinones can be hydrogenolyzed directly to provide alpha,beta-disubstituted-beta-amino acids.

  13. 26 CFR 41.4482(b)-1 - Definition of taxable gross weight.

    Science.gov (United States)

    2010-04-01

    ... Motor Vehicles § 41.4482(b)-1 Definition of taxable gross weight. (a) Actual unloaded weight—(1) In... general. The taxable gross weight of a highway motor vehicle is the sum of the actual unloaded weight of the vehicle fully equipped for service, the actual unloaded weight of any semitrailers or trailers...

  14. Benjamin Thompson, Count Rumford Count Rumford on the nature of heat

    CERN Document Server

    Brown, Sanborn C

    1967-01-01

    Men of Physics: Benjamin Thompson - Count Rumford: Count Rumford on the Nature of Heat covers the significant contributions of Count Rumford in the fields of physics. Count Rumford was born with the name Benjamin Thompson on March 23, 1753, in Woburn, Massachusetts. This book is composed of two parts encompassing 11 chapters, and begins with a presentation of Benjamin Thompson's biography and his interest in physics, particularly as an advocate of an """"anti-caloric"""" theory of heat. The subsequent chapters are devoted to his many discoveries that profoundly affected the physical thought

  15. {sup 90}Sr in human excretion samples. Comparison of MC-ICP-MS and conventional low-level beta-counting; {sup 90}Sr in menschlichen Ausscheidungsproben. Vergleich zwischen MC-ICP-MS und konventioneller Low Level Beta-Messung

    Energy Technology Data Exchange (ETDEWEB)

    Burow, M.; Schumacher, C.; Zoriy, M. [Forschungszentrum Juelich GmbH (Germany). Geschaeftsbereich fuer Sicherheit und Strahlenschutz

    2016-07-01

    At the present for determination of {sup 90}Sr in different human excretion samples manly radiochemical methods are applied, for example LL-beta- counter or liquid scintillation method. These methods require an isolation of strontium from other interfering radioactive species such as e.g. lead, polonium, plutonium, neptunium and potassium (for example, separation on Sr Resin, Fa. Eichrom, France) and afterwards long counting time restrict the usage in some application fields. On the other hand, the liquid scintillation techniques that may be used for detection present a challenge in the analysis of {sup 90}Sr in the presence of {sup 90}Y. However spectra of both radionuclides overlap in a certain zone and this may be resolved by mathematical calculations of {sup 90}Y ingrowth or by simply waiting for radiochemical equilibrium to be reached (2-3 weeks). In the case of emergency, monitoring of operating personal or civil population for possible incorporation of {sup 90}Sr via excretion samples a readily available, faster and reliable analytical procedure may prove to be of great importance. For these purposes, an analytical method for the determination of {sup 90}Sr in urine with high-sensitive MC-ICP-MS was developed in the radiochemical laboratory of the Department for Safety and Radiation Protection. The method was optimized to avoid a multitude of isobaric interferences that occur on m/z 90 using a cold-plasma operation condition of ICP-MS. The reported LOD as low as 0,3-1 Bq/l in the water samples was found to be acceptable for majority of our analytical tasks.

  16. In-trap decay spectroscopy for {beta}{beta} decays

    Energy Technology Data Exchange (ETDEWEB)

    Brunner, Thomas

    2011-01-18

    The presented work describes the implementation of a new technique to measure electron-capture (EC) branching ratios (BRs) of intermediate nuclei in {beta}{beta} decays. This technique has been developed at TRIUMF in Vancouver, Canada. It facilitates one of TRIUMF's Ion Traps for Atomic and Nuclear science (TITAN), the Electron Beam Ion Trap (EBIT) that is used as a spectroscopy Penning trap. Radioactive ions, produced at the radioactive isotope facility ISAC, are injected and stored in the spectroscopy Penning trap while their decays are observed. A key feature of this technique is the use of a strong magnetic field, required for trapping. It radially confines electrons from {beta} decays along the trap axis while X-rays, following an EC, are emitted isotropically. This provides spatial separation of X-ray and {beta} detection with almost no {beta}-induced background at the X-ray detector, allowing weak EC branches to be measured. Furthermore, the combination of several traps allows one to isobarically clean the sample prior to the in-trap decay spectroscopy measurement. This technique has been developed to measure ECBRs of transition nuclei in {beta}{beta} decays. Detailed knowledge of these electron capture branches is crucial for a better understanding of the underlying nuclear physics in {beta}{beta} decays. These branches are typically of the order of 10{sup -5} and therefore difficult to measure. Conventional measurements suffer from isobaric contamination and a dominating {beta} background at theX-ray detector. Additionally, X-rays are attenuated by the material where the radioactive sample is implanted. To overcome these limitations, the technique of in-trap decay spectroscopy has been developed. In this work, the EBIT was connected to the TITAN beam line and has been commissioned. Using the developed beam diagnostics, ions were injected into the Penning trap and systematic studies on injection and storage optimization were performed. Furthermore, Ge

  17. The Relationship between Gross Motor Skills and Academic Achievement in Children with Learning Disabilities

    Science.gov (United States)

    Westendorp, Marieke; Hartman, Esther; Houwen, Suzanne; Smith, Joanne; Visscher, Chris

    2011-01-01

    The present study compared the gross motor skills of 7- to 12-year-old children with learning disabilities (n = 104) with those of age-matched typically developing children (n = 104) using the Test of Gross Motor Development-2. Additionally, the specific relationships between subsets of gross motor skills and academic performance in reading,…

  18. Intrahepatic cholangiocarcinoma : gross appearance and corresponding pathologic and radiologic features

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Kim, Chang Guhn; Lee, Moon Gyu; Ha, Hyun Kwon; Auh, Yong Ho; Lim, Jae Hoon

    1999-01-01

    To assess the clinical and pathologic features of each type of intrahepatic cholangiocarcinoma, which is divided into three types according to gross appearance, and to determine the efficacy of CT in detecting this tumor. The pathologic and CT features of 53 surgically proven cases of intrahepatic cholangio-carcinoma were reviewed. On the basis of their gross appearance, the tumors were divided into three types, as follows : mass forming (n=33), periductal infiltrating (n=6), and intraductal growth type (n=14). CT scans were analyzed for sensitivity of detection and correlation between a tumors appearance and its histopathology. The most common histopathologic feature of mass forming and periductal infiltrating type was tubular adenocarcinoma, while in the intraductal growth type, papillary adenocarcinoma (100%) was common. With regard to pattern of tumor spread, intrahepatic and lymph node metastasis were more common in the mass forming and periductal infiltrating type than in the intraductal growth type. CT findings including intrahepatic mass, ductal wall thickening or intraductal mass associated with segmental dilatation of intrahepataic bile ducts, corresponded with these morphologic types. This classification according to gross appearance is of considerable value when interpreting the pathologic features of intrahepatic cholangiocarcinoma. CT seems to be a useful modality for the detection of tumors and may be consistent with their gross morphologic findings

  19. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  20. BetaTPred: prediction of beta-TURNS in a protein using statistical algorithms.

    Science.gov (United States)

    Kaur, Harpreet; Raghava, G P S

    2002-03-01

    beta-turns play an important role from a structural and functional point of view. beta-turns are the most common type of non-repetitive structures in proteins and comprise on average, 25% of the residues. In the past numerous methods have been developed to predict beta-turns in a protein. Most of these prediction methods are based on statistical approaches. In order to utilize the full potential of these methods, there is a need to develop a web server. This paper describes a web server called BetaTPred, developed for predicting beta-TURNS in a protein from its amino acid sequence. BetaTPred allows the user to predict turns in a protein using existing statistical algorithms. It also allows to predict different types of beta-TURNS e.g. type I, I', II, II', VI, VIII and non-specific. This server assists the users in predicting the consensus beta-TURNS in a protein. The server is accessible from http://imtech.res.in/raghava/betatpred/

  1. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase; Validacion de la cuantificacion de actividad de emisores beta en orina mediante espectrometria de centelleo en fase liquida

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-07-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ({sup 3}H, {sup 1}4C, {sup 3}5S, {sup 3}2P and {sup 9}0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  2. Roughing up Beta

    DEFF Research Database (Denmark)

    Bollerslev, Tim; Li, Sophia Zhengzi; Todorov, Viktor

    -section. An investment strategy that goes long stocks with high jump betas and short stocks with low jump betas produces significant average excess returns. These higher risk premiums for the discontinuous and overnight market betas remain significant after controlling for a long list of other firm characteristics......Motivated by the implications from a stylized equilibrium pricing framework, we investigate empirically how individual equity prices respond to continuous, or \\smooth," and jumpy, or \\rough," market price moves, and how these different market price risks, or betas, are priced in the cross......-section of expected returns. Based on a novel highfrequency dataset of almost one-thousand individual stocks over two decades, we find that the two rough betas associated with intraday discontinuous and overnight returns entail significant risk premiums, while the intraday continuous beta is not priced in the cross...

  3. Measurement of radionuclides in various environmental samples and in items of diet of the local population. Part of a coordinated programme on environmental monitoring for radiological protection in Asia and the Far East

    International Nuclear Information System (INIS)

    Aziz, A.

    1980-03-01

    The research covered identification of radionuclides and measurement of their concentration in various environmental media and items of diet of the local population. Biomedia and items of diet selected for study were air, surface water, precipitation, vegetables, meat, poultry and fish etc. Radioactive assays under-taken were gross gamma activity measurements and gamma spectrometric analyses for the determination of gamma emitting radionuclides. These were followed by radiochemical analyses for the separation of Sr 90 and Pu 239. Radiometric measurements for Sr 90 and Pu 239 were performed by low back-ground beta counting and alpha spectrometric analyses respectively

  4. A global assessment of gross and net land change dynamics for current conditions and future scenarios

    Directory of Open Access Journals (Sweden)

    R. Fuchs

    2018-05-01

    Full Text Available The consideration of gross land changes, meaning all area gains and losses within a pixel or administrative unit (e.g. country, plays an essential role in the estimation of total land changes. Gross land changes affect the magnitude of total land changes, which feeds back to the attribution of biogeochemical and biophysical processes related to climate change in Earth system models. Global empirical studies on gross land changes are currently lacking. Whilst the relevance of gross changes for global change has been indicated in the literature, it is not accounted for in future land change scenarios. In this study, we extract gross and net land change dynamics from large-scale and high-resolution (30–100 m remote sensing products to create a new global gross and net change dataset. Subsequently, we developed an approach to integrate our empirically derived gross and net changes with the results of future simulation models by accounting for the gross and net change addressed by the land use model and the gross and net change that is below the resolution of modelling. Based on our empirical data, we found that gross land change within 0.5° grid cells was substantially larger than net changes in all parts of the world. As 0.5° grid cells are a standard resolution of Earth system models, this leads to an underestimation of the amount of change. This finding contradicts earlier studies, which assumed gross land changes to appear in shifting cultivation areas only. Applied in a future scenario, the consideration of gross land changes led to approximately 50 % more land changes globally compared to a net land change representation. Gross land changes were most important in heterogeneous land systems with multiple land uses (e.g. shifting cultivation, smallholder farming, and agro-forestry systems. Moreover, the importance of gross changes decreased over time due to further polarization and intensification of land use. Our results serve as

  5. Gross-Pitaevski map as a chaotic dynamical system.

    Science.gov (United States)

    Guarneri, Italo

    2017-03-01

    The Gross-Pitaevski map is a discrete time, split-operator version of the Gross-Pitaevski dynamics in the circle, for which exponential instability has been recently reported. Here it is studied as a classical dynamical system in its own right. A systematic analysis of Lyapunov exponents exposes strongly chaotic behavior. Exponential growth of energy is then shown to be a direct consequence of rotational invariance and for stationary solutions the full spectrum of Lyapunov exponents is analytically computed. The present analysis includes the "resonant" case, when the free rotation period is commensurate to 2π, and the map has countably many constants of the motion. Except for lowest-order resonances, this case exhibits an integrable-chaotic transition.

  6. GLOBALIZATION AND GROSS DOMESTIC PRODUCT CONSTRUCTION IN ASEAN

    Directory of Open Access Journals (Sweden)

    Muhammad Sri Wahyudi Suliswanto

    2011-09-01

    Full Text Available There is no more doubt about the importance of economic growth, which can be calculated fromGross Domestic Product (GDP. This research analyzes the role of globalization on GDP inASEAN-5 by estimating panel data. It uses a fixed effect approach to accommodate various characteristicsin the countries. To accommodate such variation, it assumes that the intercepts variesacross these countries, while the slopes remain similar. Based on the estimation result, it suggeststhat net export and foreign direct investment represent the globalization process. Both have positiveand significant influences on GDP in the corresponding countries.Keywords: Globalization, international trade, foreign direct investment, gross domestic productJEL classification numbers: E01, F51, F43

  7. Short communication: Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count.

    Science.gov (United States)

    Koop, G; Dik, N; Nielen, M; Lipman, L J A

    2010-06-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC (Fossomatic 5000, Foss, Hillerød, Denmark) and TBC (BactoScan FC 150, Foss) were measured. Staphylococcal count was correlated to SCC (r=0.40), TBC (r=0.51), and SPC (r=0.53). Coliform count was correlated to TBC (r=0.33), but not to any of the other variables. Staphylococcus aureus did not correlate to SCC. The contribution of the staphylococcal count to the SPC was 31%, whereas the coliform count comprised only 1% of the SPC. The agreement of the repeated measurements was low. This study indicates that staphylococci in goat bulk milk are related to SCC and make a significant contribution to SPC. Because of the high variation in bacterial counts, repeated sampling is necessary to draw valid conclusions from bulk milk culturing. 2010 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  8. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, S. [Education Faculty, Kastamonu University, 37200 Kastamonu (Turkey)], E-mail: syalcin@kastamonu.edu.tr; Gurler, O. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey); Gundogdu, O. [Department of Physics, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford, GU2 7XH (United Kingdom); NCCPM, Medical Physics, Royal Surrey County Hospital, Guildford, GU2 7XX (United Kingdom); Kaynak, G. [Department of Physics, Faculty of Arts and Sciences, Uludag University, Gorukle Campus, 16059 Bursa (Turkey)

    2009-01-15

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies.

  9. Monte Carlo simulation of gamma-ray total counting efficiency for a Phoswich detector

    International Nuclear Information System (INIS)

    Yalcin, S.; Gurler, O.; Gundogdu, O.; Kaynak, G.

    2009-01-01

    The LB 1000-PW detector is mainly used for determining total alpha, beta and gamma activity of low activity natural sources such as water, soil, air filters and any other environmental sources. Detector efficiency needs to be known in order to measure the absolute activity of such samples. This paper presents results on the total gamma counting efficiency of a Phoswich detector from point and disk sources. The directions of photons emitted from the source were determined by Monte Carlo techniques and the true path lengths in the detector were determined by analytical equations depending on photon directions. Results are tabulated for various gamma energies

  10. Probing the diphosphoglycerate binding pocket of HbA and HbPresbyterian (beta 108Asn --> Lys).

    Science.gov (United States)

    Gottfried, D S; Manjula, B N; Malavalli, A; Acharya, A S; Friedman, J M

    1999-08-31

    HbPresbyterian (beta 108Asn --> Lys, HbP) contains an additional positive charge (per alpha beta dimer) in the middle of the central cavity and exhibits a lower oxygen affinity than wild-type HbA in the presence of chloride. However, very little is known about the molecular origins of its altered functional properties. In this study, we have focused on the beta beta cleft of the Hb tetramer. Recently, we developed an approach for quantifying the ligand binding affinity to the beta-end of the Hb central cavity using fluorescent analogues of the natural allosteric effector 2, 3-diphosphoglycerate (DPG) [Gottfried, D. S., et al. (1997) J. Biol. Chem. 272, 1571-1578]. Time-correlated single-photon counting fluorescence lifetime studies were used to assess the binding of pyrenetetrasulfonate to both HbA and HbP in the deoxy and CO ligation states under acidic and neutral pH conditions. Both the native and mutant proteins bind the probe at a weak binding site and a strong binding site; in all cases, the binding to HbP was stronger than to HbA. The most striking finding was that for HbA the binding affinity varies as follows: deoxy (pH 6.35) > deoxy (pH 7.20) > CO (pH 6.35); however, the binding to HbP is independent of ligation or pH. The mutant oxy protein also hydrolyzes p-nitrophenyl acetate, through a reversible acyl-imidazole pathway linked to the His residues of the beta beta cleft, at a considerably higher rate than does HbA. This implies a perturbation of the microenvironment of these residues at the DPG binding pocket. Structural consequences due to the presence of the new positive charge in the middle of the central cavity have been transmitted to the beta beta cleft of the protein, even in its liganded conformation. This is consistent with a newly described quaternary state (B) for liganded HbPresbyterian and an associated change in the allosteric control mechanism.

  11. Levels of radioactivity in fish from streams near F-Area and H-Area seepage basins

    International Nuclear Information System (INIS)

    Murphy, C.E. Jr.; Loehle, C.

    1991-05-01

    This report summarizes results of recent analyses of radioactivity in fish from SRS streams near the F-Area and H-Area seepage basins. Fish were collected from headwater areas of Four Mile Creek and Pen Branch, from just below the H-Area seepage basin, and from three sites downstream in Four Mile Creek. These fish were analyzed for gross alpha and gross beta radioactivity using standard EPA methods. Levels of gross alpha and nonvolatile beta radioactivity in fish were found to be comparable to levels previously reported for these sites. Gross alpha activity was not found to be influenced by Separations Area discharges. Nonvolatile beta activity was higher in the nonvolatile beta activity was attributable to Cs-137 and K-40. The dosimetric consequences of consuming fish from this area were found to be well below DOE guidelines

  12. Development of a Computerized Adaptive Test of Children's Gross Motor Skills.

    Science.gov (United States)

    Huang, Chien-Yu; Tung, Li-Chen; Chou, Yeh-Tai; Wu, Hing-Man; Chen, Kuan-Lin; Hsieh, Ching-Lin

    2018-03-01

    To (1) develop a computerized adaptive test for gross motor skills (GM-CAT) as a diagnostic test and an outcome measure, using the gross motor skills subscale of the Comprehensive Developmental Inventory for Infants and Toddlers (CDIIT-GM) as the candidate item bank; and (2) examine the psychometric properties and the efficiency of the GM-CAT. Retrospective study. A developmental center of a medical center. Children with and without developmental delay (N=1738). Not applicable. The CDIIT-GM contains 56 universal items on gross motor skills assessing children's antigravity control, locomotion, and body movement coordination. The item bank of the GM-CAT had 44 items that met the dichotomous Rasch model's assumptions. High Rasch person reliabilities were found for each estimated gross motor skill for the GM-CAT (Rasch person reliabilities =.940-.995, SE=.68-2.43). For children aged 6 to 71 months, the GM-CAT had good concurrent validity (r values =.97-.98), adequate to excellent diagnostic accuracy (area under receiver operating characteristics curve =.80-.98), and moderate to large responsiveness (effect size =.65-5.82). The averages of items administered for the GM-CAT were 7 to 11, depending on the age group. The results of this study support the use of the GM-CAT as a diagnostic and outcome measure to estimate children's gross motor skills in both research and clinical settings. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  13. Liver X receptor activation inhibits PC-3 prostate cancer cells via the beta-catenin pathway.

    Science.gov (United States)

    Youlin, Kuang; Li, Zhang; Weiyang, He; Jian, Kang; Siming, Liang; Xin, Gou

    2017-03-01

    Liver X receptors (LXRs) are nuclear receptors family of ligand-dependent transcription factors that play a crucial role in regulating cholesterol metabolism and inflammation. Recent studies show that LXR agonists exhibit anti-cancer activities in a variety of cancer cell lines including prostate. To further identify the potential mechanisms of LXRα activation on prostate cancer, we investigated the effect of LXR agonist T0901317 on PC3 prostate cancer cell and in which activity of beta-catenin pathway involved. Prostate cancer PC3 cells were transfected with LXR-a siRNA and treated with LXR activator T0901317. qRT-PCR and western blot were used to detect the LXR-a expression. beta-catenin, cyclin D1 and c-MYC were analyzed by western blot. Cell apoptosis was examined by flow cytometry and Cell proliferation was assessed by Cell Counting Kit-8 assay. Cell migration was detected by Transwell chambers. Data showed that T0901317 significantly inhibited PC3 cell proliferation as well as invasion and increased apoptosis in vitro. Furthermore, we found that LXRα activation induced the reduction of beta-catenin expression in PC3 cells, and this inhibitory effect could be totally abolished when cells were treated with LXRα. Meanwhile, the expression of beta-catenin target gene cyclin D1 and c-MYC were also decreased. This study provided additional evidence that LXR activation inhibited PC-3 prostate cancer cells via suppressing beta-catenin pathway. Copyright © 2016 Elsevier GmbH. All rights reserved.

  14. Plasma beta-endorphin, beta-lipotropin and corticotropin in polycystic ovarian disease.

    Science.gov (United States)

    Laatikainen, T; Salminen, K; Virtanen, T; Apter, D

    1987-04-01

    In 9 women with polycystic ovarian disease (PCOD) and in 11 control subjects at the follicular phase of the normal cycle, blood samples were collected at 15-min intervals during a 2 h period of bed rest for the assay of beta-endorphin, beta-lipotropin, corticotropin, cortisol and prolactin. During the study period, the plasma levels of these hormones decreased more significantly in the PCOD than in the control group, suggesting that the PCOD patients had a more significant stress response to the puncture of the vein than the control subjects. The second hour of the study period was considered to represent resting levels of hormones. The mean resting levels (+/- S.E.) of the hormones between the PCOD and control groups, respectively, were as follows: beta-E, 2.0 +/- 0.4 vs. 1.1 +/- 0.1 pmol/l, p less than 0.05; beta-LPH, 3.4 +/- 0.6 vs. 2.1 +/- 0.5 pmol/l, N.S.; corticotropin, 2.0 +/- 0.3 vs. 1.1 +/- 0.5 pmol/l, p less than 0.05; cortisol, 176 +/- 24 vs. 128 +/- 16, N.S.; and prolactin; 3.9 +/- 0.6 vs. 5.6 +/- 1.2 ng/ml, N.S. These results confirm the previous findings on increased circulating levels of beta-E in PCOD. A concomitant increase of the plasma level of corticotropin suggests that the basal secretion of both beta-E and corticotropin from the anterior pituitary gland is increased in women with PCOD.

  15. Contra-expertise on determination of radioactivity of waste water and ventilation air of Urenco Nederland B.V. Period 2011; Contra-expertise op bepalingen van radioactiviteit van afvalwater en ventilatielucht van Urenco Nederland BV. Periode 2011

    Energy Technology Data Exchange (ETDEWEB)

    Kwakman, P.J.M.; Overwater, R.M.W.

    2012-08-15

    Within the framework of a monitoring programme, RIVM measures the release of radioactivity into the waste water and atmosphere of the Urenco uranium enrichment plant in Almelo, Netherlands. Measurements are carried out eight times per year. This form of counter-expertise is aimed at verifying and supporting the reliability of the analyses carried out by the Urenco plant. As a rule, the waste water contains very low levels of gross alpha and gross beta activity. The two different sets of measurements of gross alpha and gross beta in waste water are generally in agreement, as is also the case in 2011. Radioactivity levels in the ventilation air are very close to those levels expected due to the natural presence of radon in the outside atmosphere. For gross alpha 0,007 - 0,13 mBq.m{sup -3} was found and for gross beta 0,026 - 0,5 mBq.m{sup -3}. The agreement with the measurement results of Urenco was mostly good. Taking into account the natural gross-beta activity, and the ratio gross alpha / gross beta it is possible that at SP4 in two cases a small release of uranium may have occurred. The RIVM determined the gross alpha and gross beta activity in eight waste water samples and 40 samples of ventilation air. The samples were taken by Urenco at time points dispersed throughout 2011. This procedure provides the RIVM with a method for determining the release of artificial alpha emitters into the environment. The analyses were carried out on behalf of the Department of Nuclear Safety, Security and Safeguards of the Human Environment and Transport Inspectorate from the Ministry of Infrastructure and Environment [Dutch] Het RIVM controleert achtmaal per jaar de metingen van de verrijkingsfabriek Urenco te Almelo. Het gaat hierbij om lozingen van radioactiviteit in water en lucht. De contra-expertise onderbouwt de betrouwbaarheid van de analyses die Urenco uitvoert. Uit de metingen blijkt dat er in het afvalwater doorgaans een (zeer) lage totaal {alpha} en totaal {beta

  16. Are gross motor skills and sports participation related in children with intellectual disabilities?

    Science.gov (United States)

    Westendorp, Marieke; Houwen, Suzanne; Hartman, Esther; Visscher, Chris

    2011-01-01

    This study compared the specific gross motor skills of 156 children with intellectual disabilities (ID) (50 ≤ IQ ≥ 79) with that of 255 typically developing children, aged 7-12 years. Additionally, the relationship between the specific gross motor skills and organized sports participation was examined in both groups. The Test of Gross Motor Development-2 and a self-report measure were used to assess children's gross motor skills and sports participation, respectively. The children with ID scored significantly lower on almost all specific motor skill items than the typically developing children. Children with mild ID scored lower on the locomotor skills than children with borderline ID. Furthermore, we found in all groups that children with higher object-control scores participated more in organized sports than children with lower object-control scores. Our results support the importance of attention for well-developed gross motor skills in children with borderline and mild ID, especially to object-control skills, which might contribute positively to their sports participation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Radiological quality in drinking water from Granada city; Calidad radiologica del agua potable de la ciudad de Granada

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Penalver, J. J.; Gonzalez Gomez, C.; Ferro Garcia, M. A.; Prados Joya, G.

    2007-07-01

    The purpose of this study is to present data on gross alpha and beta activities in the drinking water from Granada city, during six years, 2000 to 2005. The samples were measured using a gas-flow proportional counter Bert hold LB 770-2/5. The results show that the gross alpha and gross beta cavity is lower than the maximum contaminant level based on the World Health Organisation, who which indicates 0.1 Bq.1-1 and 1.0 Bq.l''-1 as maximum contaminant level of gross alpha and gross beta radioactivity in potable water, respectively. Concentration ranging from 4.1.10''-3 to 3.9.10''2 Bq.l''-1 and from 4.9.10''-3 to 5.6.10''-2 Bq.l''-1 were observed from the gross alpha and beta activities, respectively. An average annual effective dose equivalent of 2.909 {mu}Sv-yr''-1 was obtained together with a range of 0.186 to 0.326 {mu}Sv.mo''-1. (Author) 10 refs.

  18. Validation the quantification of beta emitters activity in urine by scintillation spectrometry in the liquid phase

    International Nuclear Information System (INIS)

    Sierra, I.; Hernandez, C.; Benito, P.; Lopez, C.

    2013-01-01

    In this paper the methodology used in the validation of the technique for quantifying activity of some beta emitters in urine ( 3 H, 1 4C, 3 5S, 3 2P and 9 0Sr) by scintillation spectrometry Liquid Phase (Liquid Scintillation Counting, LSC) is described in bio elimination Laboratory Service CIEMAT Radiation Dosimetry accredited since last year for carrying out assays measure radiation dose based on ISO forth above. (Author)

  19. High speed quantitative digital beta autoradiography using a multi-step avalanche detector and an Apple-II microcomputer

    International Nuclear Information System (INIS)

    Bateman, J.E.; Connolly, J.F.; Stephenson, R.

    1985-04-01

    The development of an electronic, digital beta autoradiography system is described. Using a Multi-Step Avalanche/Multi-Wire Proportional Counter (MSA/MWPC) detector system fitted with delay line readout, high speed digital imaging is demonstrated with sub-millimeter spatial resolution. Good proportionality of observed counting rate relative to the known tritium activity is demonstrated. The application of the system to autoradiography in immunoelectrophoresis, histopathology and DNA sequencing is described. (author)

  20. ϵ-expansion in the Gross-Neveu

    Energy Technology Data Exchange (ETDEWEB)

    Raju, Avinash [Center for High Energy Physics, Indian Institute of Science,Bangalore 560012 (India)

    2016-10-18

    We use the recently developed CFT techniques of Rychkov and Tan to compute anomalous dimensions in the O(N) Gross-Neveu model in d=2+ϵ dimensions. To do this, we extend the “cowpie contraction' algorithm of http://arxiv.org/abs/1506.06616 to theories with fermions. Our results match perfectly with Feynman diagram computations.

  1. On Fuzzy {beta}-I-open sets and Fuzzy {beta}-I-continuous functions

    Energy Technology Data Exchange (ETDEWEB)

    Keskin, Aynur [Department of Mathematics, Faculty of Science and Arts, Selcuk University, Campus, 42075 Konya (Turkey)], E-mail: akeskin@selcuk.edu.tr

    2009-11-15

    In this paper, first of all we obtain some properties and characterizations of fuzzy {beta}-I-open sets. After that, we also define the notion of {beta}-I-closed sets and obtain some properties. Lastly, we introduce the notions of fuzzy {beta}-I-continuity with the help of fuzzy {beta}-I-open sets to obtain decomposition of fuzzy continuity.

  2. Clusters of conserved beta cell marker genes for assessment of beta cell phenotype

    DEFF Research Database (Denmark)

    Martens, Geert A; Jiang, Lei; Hellemans, Karine H

    2011-01-01

    The aim of this study was to establish a gene expression blueprint of pancreatic beta cells conserved from rodents to humans and to evaluate its applicability to assess shifts in the beta cell differentiated state. Genome-wide mRNA expression profiles of isolated beta cells were compared to those...... of a large panel of other tissue and cell types, and transcripts with beta cell-abundant and -selective expression were identified. Iteration of this analysis in mouse, rat and human tissues generated a panel of conserved beta cell biomarkers. This panel was then used to compare isolated versus laser capture...... microdissected beta cells, monitor adaptations of the beta cell phenotype to fasting, and retrieve possible conserved transcriptional regulators....

  3. Summarized report of geothermal well Gross Buchholz Gt1; Kurzprofil der Geothermiebohrung Gross Buchholz Gt1

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Frauke; Hesshaus, Annalena; Jatho, Reiner; Luppold, Friedrich-Wilhelm; Pletsch, Thomas; Tischner, Torsten [Bundesanstalt fuer Geowissenschaften und Rohstoffe (BGR), Hannover (Germany); Hunze, Sabine; Orilski, Judith; Wonik, Thomas [Leibniz-Institut fuer Angewandte Geophysik (LIAG), Hannover (Germany); Roehling, Heinz-Gerd [Landesamt fuer Bergbau, Energie und Geologie (LBEG), Hannover (Germany)

    2012-01-15

    The well Gross Buchholz Gt1 is a deep geothermal well intended to demonstrate the feasibility of deep geothermal energy mining from tight sedimentary rocks. It is the core part of the GeneSys (Generated Geothermal Energy Systems) project, aiming at developing single well concepts for direct use of geothermal energy. During the course of the project, three different single well concepts have been developed and tested at the research well Horstberg Z1 which is geologically comparable to the Gross Buchholzwell. The latter is intended to supply the heating energy for the premises of Geozentrum Hannover, an office and lab complex of some 35.000 m{sup 2} housing about 1000 employees. The geothermal target are the sandstones of the Lower Triassic Middle Buntsandstein Formation, which have a temperature of about 165 C at 3700 depth. The well has reached a final depth of 3901 m below ground level, penetrating a nearly complete succession from the Lower Cretaceous (Albian) to the Lower Triassic (Lower Buntsandstein), while Tertiary and Upper Cretaceous sediments are missing. This article summarizes technical and geographic data, stratigraphic classification, geophysical logging, cores, and sidewall cores of the well. (orig.)

  4. N-Benzylhydroxylamine addition to beta-aryl enoates. Enantioselective synthesis of beta-aryl-beta-amino acid precursors

    Science.gov (United States)

    Sibi; Liu

    2000-10-19

    Chiral Lewis acid catalyzed N-benzylhydroxylamine addition to pyrrolidinone-derived enoates afforded beta-aryl-beta-amino acid derivatives in high enantiomeric purity with moderate to very good chemical efficiency.

  5. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  6. Gross Revenue risk in Swiss dairy farming

    NARCIS (Netherlands)

    Benni, El N.; Finger, R.

    2013-01-01

    This study investigated how agricultural policy reforms, including market liberalization and market deregulation, have influenced gross revenue risk of Swiss dairy producers using farm-level panel data between 1990 and 2009. Based on detrended data, variance decomposition was applied to assess how

  7. An On-Line Water Monitor for Low Level {beta}-Radioactivity Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Quirk, E J.M.

    1968-05-15

    A detection system is described for the continuous monitoring of {beta}-radioactivity in the secondary cooling water at the Studsvik R2 reactor. Radiation emanating from a water surface is measured by a large area gas proportional detector. To protect the detector from splash caused by bursting bubbles a protective film and heater assembly is interposed between the detector and the water surface. A special feature is the programmed 'exercise' sequence for the magnetic valves which eliminates a tendency for them to stick after prolonged periods of idleness. The extent to which contamination affects the background counting rate has been studied. It is shown that for the duration of the tests described the monitor remains free from the effects of contamination so long as the scaler live time is suitably chosen. Minimum measurable specific activities obtainable in practice extend from 4 x 10{sup -6} to 3.86 x 10{sup -8} Ci/m{sup 3} depending on the {beta} end-point energy in the range 167 keV - 2.26 MeV.

  8. Beta Emission and Bremsstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-13

    Bremsstrahlung is continuous radiation produced by beta particles decelerating in matter; different beta emitters have different endpoint energies; high-energy betas interacting with high-Z materials will more likely produce bremsstrahlung; depending on the data, sometimes all you can say is that a beta emitter is present.

  9. A variational approach to the Gross-Neveu model

    International Nuclear Information System (INIS)

    Mishra, H.; Misra, P.; Mishra, A.

    1988-01-01

    The authors solve the instability of perturbative vacuum of Gross-Neveu model. They use a variational method. The analysis is nonperturbative as it uses only equal time commmutator/anticommutator algebra

  10. Standardization of {sup 241}Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    Energy Technology Data Exchange (ETDEWEB)

    Balpardo, C., E-mail: balpardo@cae.cnea.gov.a [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina); Capoulat, M.E.; Rodrigues, D.; Arenillas, P. [Laboratorio de Metrologia de Radioisotopos, CNEA, Buenos Aires (Argentina)

    2010-07-15

    The nuclide {sup 241}Am decays by alpha emission to {sup 237}Np. Most of the decays (84.6%) populate the excited level of {sup 237}Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of {sup 241}Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  11. Nuclear Matrix Elements for the $\\beta\\beta$ Decay of the $^{76}$Ge

    CERN Document Server

    Brown, B A; Horoi, M

    2015-01-01

    The nuclear matrix elements for two-neutrino double-beta (2 n$\\beta\\beta$ ) and zero-neutrino double-beta (0 n$\\beta\\beta$) decay of 76 Ge are evaluated in terms of the configuration interaction (CI), quasiparticle random phase approximation (QRPA) and interacting boson model (IBM) methods. We show that the decomposition of the matrix elements in terms of interemediate states in 74 Ge is dominated by ground state of this nucleus. We consider corrections to the CI results that arise from configurations admixtures involving orbitals out-side of the CI configuration space by using results from QRPA, many-body-perturbation theory, and the connections to related observables. The CI two-neutrino matrix element is reduced due to the inclusion of spin-orbit partners, and to many-body correlations connected with Gamow-Teller beta decay. The CI zero-neutrino matrix element for the heavy neutrino is enhanced due to particle-particle correlations that are connected with the odd-even oscillations in the nuclear masse...

  12. Scintillation detector for dosing unknown {beta} emitters deposited on large-surface filters (1963); Detecteur a scintillation pour la dosimetrie d'emetteurs beta inconnus deposes sur filtre de grande surface (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Soudain, G; Cercy, J; Geoffre, B [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1963-07-01

    The apparatus described has been specially studied for direct counting, using a plastic scintillator, of unknown emitters occurring in atmospheric samples collected on large-surface filters (10 cm diameter). In view of the fairly large contribution of low-energy fission products to the overall {beta}-activity of radio-active fallout, the adjustments have been chosen so as to obtain the best yield in an energy range as wide as possible. This has led to the acceptance of a certain background noise which is later reduced by the anti-coincidence method. The quality of the apparatus depends largely on the uniformity of the photocathode in the photomultiplier used. The counter which was built had a counting efficiency for a 10 cm diameter source of 30 per cent for S-35, 88 per cent for P-32, 45 per cent for unknown emitters and a background noise of 56 cpm. (authors) [French] L'appareil decrit a ete specialement etudie pour le comptage direct, a l'aide d'un scintillateur plastique d'emetteurs inconnus recueillis dans les prelevements atmospheriques sur des filtres de grande surface (10 cm de diametre). Etant donne la participation assez importante des produits de fission de faible energie a l'activite globale {beta} des retombees radioactives, les reglages ont ete choisis de maniere a obtenir le meilleur rendement dans une gamme d'energie aussi etendue que possible. Cela a conduit a admettre un certain bruit de fond que l'on reduit ensuite par la methode d'anticoincidence. La qualite de l'appareil depend en grande partie de l'uniformite de la photocathode du photomultiplicateur utilise. Le compteur que l'on a construit possede une efficacite de comptage pour une source de 10 cm de diametre de 30 pour cent pour {sup 35}S, 88 pour cent pour {sup 32}P, 45 pour des emetteurs {beta} inconnus et un bruit de fond de 56 cpm. (auteurs)

  13. The results of investigation in connection with the 18th Chinese nuclear test

    International Nuclear Information System (INIS)

    1977-01-01

    Concerning the 18th nuclear explosion test of the People's Republic of China, the results of measurements of radioactivity, etc. in Japan are presented. (1) As for gross beta-radioactivity in upper air, the same level as normal was measured in middle and northern Japan. (2) At monitoring posts, the same level as normal was measured across the country. (3) As for gross beta-radioactivity in rain and dry fallout, 56 pCi/ml was detected in Hachijo Island. (4) As for gross beta-radioactivity in airborne dust, 6.0 pCi/m 3 was detected in Fukuoka. (5) As for gross beta-radioactivity in dry fallout the same level as normal was measured. (6) As for the Iodine-131 concentration in fresh milk, 113 pCi/l was detected in Ishikawa Prefecture. (7) Analysis of radionuclides. (8) Data concerning the radioactivity surveillance. (J.P.N.)

  14. Production of beta-xylanase and beta-xylosidase by the extremely halophilic archaeon Halorhabdus utahensis

    DEFF Research Database (Denmark)

    Wainø, M.; Ingvorsen, K.

    2003-01-01

    -xylosidase stabilities, approximately 55% and 83% of the initial beta-xylanase and beta-xylosidase activities, respectively, remained after 24 h incubation at 20% NaCl. The enzymes were also shown to be slightly thermophilic: P-xylanase activity exhibiting two optima at 55degrees and 70degreesC, while beta......The extremely halophilic archaeon, Halorhabdus utahensis, isolated from the Great Salt Lake, Utah, produced beta-xylanase and beta-xylosidase activities. Both enzymes were active over a broad NaCl range from near zero to 30% NaCl when tested with culture broth. A broad NaCl optimum was observed...... for beta-xylanase activity between 5% and 15% NaCl, while beta-xylosidase activity was highest at 5% NaCl. Almost half of the maximum activities remained at 27%-30% NaCl for both enzyme activities. When dialyzed culture supernatant and culture broth were employed for determination of beta-xylanase and beta...

  15. Role of beta-adrenoceptors in memory consolidation: beta3-adrenoceptors act on glucose uptake and beta2-adrenoceptors on glycogenolysis.

    Science.gov (United States)

    Gibbs, Marie E; Hutchinson, Dana S; Summers, Roger J

    2008-09-01

    Noradrenaline, acting via beta(2)- and beta(3)-adrenoceptors (AR), enhances memory formation in single trial-discriminated avoidance learning in day-old chicks by mechanisms involving changes in metabolism of glucose and/or glycogen. Earlier studies of memory consolidation in chicks implicated beta(3)- rather than beta(2)-ARs in enhancement of memory consolidation by glucose, but did not elucidate whether stimulation of glucose uptake or of glycolysis was responsible. This study examines the role of glucose transport in memory formation using central injection of the nonselective facilitative glucose transporter (GLUT) inhibitor cytochalasin B, the endothelial/astrocytic GLUT-1 inhibitor phloretin and the Na(+)/energy-dependent endothelial glucose transporter (SGLT) inhibitor phlorizin. Cytochalasin B inhibited memory when injected into the mesopallium (avian cortex) either close to or between 25 and 45 min after training, whereas phloretin and phlorizin only inhibited memory at 30 min. This suggested that astrocytic/endothelial (GLUT-1) transport is critical at the time of consolidation, whereas a different transporter, probably the neuronal glucose transporter (GLUT-3), is important at the time of training. Inhibition of glucose transport by cytochalasin B, phloretin, or phlorizin also interfered with beta(3)-AR-mediated memory enhancement 20 min posttraining, whereas inhibition of glycogenolysis interfered with beta(2)-AR agonist enhancement of memory. We conclude that in astrocytes (1) activities of both GLUT-1 and SGLT are essential for memory consolidation 30 min posttraining; (2) neuronal GLUT-3 is essential at the time of training; and (3) beta(2)- and beta(3)-ARs consolidate memory by different mechanisms; beta(3)-ARs stimulate central glucose transport, whereas beta(2)-ARs stimulate central glycogenolysis.

  16. Low-beta investment strategies

    OpenAIRE

    Korn, Olaf; Kuntz, Laura-Chloé

    2015-01-01

    This paper investigates investment strategies that exploit the low-beta anomaly. Although the notion of buying low-beta stocks and selling high-beta stocks is natural, a choice is necessary with respect to the relative weighting of high-beta stocks and low-beta stocks in the investment portfolio. Our empirical results for US large-cap stocks show that this choice is very important for the risk-return characteristics of the resulting portfolios and their sensitivities to common risk factors. W...

  17. Effects of land use change on soil gross nitrogen transformation rates in subtropical acid soils of Southwest China.

    Science.gov (United States)

    Xu, Yongbo; Xu, Zhihong

    2015-07-01

    Land use change affects soil gross nitrogen (N) transformations, but such information is particularly lacking under subtropical conditions. A study was carried out to investigate the potential gross N transformation rates in forest and agricultural (converted from the forest) soils in subtropical China. The simultaneously occurring gross N transformations in soil were quantified by a (15)N tracing study under aerobic conditions. The results showed that change of land use types substantially altered most gross N transformation rates. The gross ammonification and nitrification rates were significantly higher in the agricultural soils than in the forest soils, while the reverse was true for the gross N immobilization rates. The higher total carbon (C) concentrations and C / N ratio in the forest soils relative to the agricultural soils were related to the greater gross N immobilization rates in the forest soils. The lower gross ammonification combined with negligible gross nitrification rates, but much higher gross N immobilization rates in the forest soils than in the agricultural soils suggest that this may be a mechanism to effectively conserve available mineral N in the forest soils through increasing microbial biomass N, the relatively labile organic N. The greater gross nitrification rates and lower gross N immobilization rates in the agricultural soils suggest that conversion of forests to agricultural soils may exert more negative effects on the environment by N loss through NO3 (-) leaching or denitrification (when conditions for denitrification exist).

  18. Ellagic acid promotes A{beta}42 fibrillization and inhibits A{beta}42-induced neurotoxicity

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Ying [Department of Histology and Embryology, College of Basic Medical Science, China Medical University, Shenyang 110001 (China); Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China); Yang, Shi-gao; Du, Xue-ting; Zhang, Xi; Sun, Xiao-xia; Zhao, Min [Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China); Sun, Gui-yuan, E-mail: sungy2004@sohu.com [Department of Histology and Embryology, College of Basic Medical Science, China Medical University, Shenyang 110001 (China); Liu, Rui-tian, E-mail: rtliu@tsinghua.edu.cn [Tsinghua University School of Medicine, Haidian District, Beijing 100084 (China)

    2009-12-25

    Smaller, soluble oligomers of {beta}-amyloid (A{beta}) play a critical role in the pathogenesis of Alzheimer's disease (AD). Selective inhibition of A{beta} oligomer formation provides an optimum target for AD therapy. Some polyphenols have potent anti-amyloidogenic activities and protect against A{beta} neurotoxicity. Here, we tested the effects of ellagic acid (EA), a polyphenolic compound, on A{beta}42 aggregation and neurotoxicity in vitro. EA promoted A{beta} fibril formation and significant oligomer loss, contrary to previous results that polyphenols inhibited A{beta} aggregation. The results of transmission electron microscopy (TEM) and Western blot displayed more fibrils in A{beta}42 samples co-incubated with EA in earlier phases of aggregation. Consistent with the hypothesis that plaque formation may represent a protective mechanism in which the body sequesters toxic A{beta} aggregates to render them harmless, our MTT results showed that EA could significantly reduce A{beta}42-induced neurotoxicity toward SH-SY5Y cells. Taken together, our results suggest that EA, an active ingredient in many fruits and nuts, may have therapeutic potential in AD.

  19. 26 CFR 1.924(a)-1T - Temporary regulations; definition of foreign trading gross receipts.

    Science.gov (United States)

    2010-04-01

    ... trading gross receipts. 1.924(a)-1T Section 1.924(a)-1T Internal Revenue INTERNAL REVENUE SERVICE... United States § 1.924(a)-1T Temporary regulations; definition of foreign trading gross receipts. (a) In general. The term “foreign trading gross receipts” means any of the five amounts described in paragraphs...

  20. Vitamin A and beta-carotene concentrations in adults with HIV/AIDS on highly active antiretroviral therapy.

    Science.gov (United States)

    Kaio, Daniella Junko; Rondó, Patricia Helen Carvalho; Souza, José Maria Pacheco; Firmino, Aline Vale; Luzia, Liania Alves; Segurado, Aluisio Augusto

    2013-01-01

    Micronutrient deficiency is a common condition in HIV-infected individuals and may occur in all stages of the disease. The objective of this cross-sectional study was to compare the concentrations of vitamin A and beta-carotene, micronutrients related to immunity and oxidative stress, in 182 adults with HIV/AIDS, under different highly active antiretroviral therapy (HAART) regimens. Patients were divided into 3 groups according to their HAART regimen: combination of nucleoside analog reverse transcriptase inhibitors (NRTIs) and non-NRTIs; combination of NRTIs, protease inhibitors, and ritonavir; combination of NRTIs and other classes. Multiple linear regression analysis determined the effect of the treatment regimen, time of use, and compliance with the regimen, on vitamin A and beta-carotene concentrations, controlling for the following variables: gender, age, educational level, smoking, physical activity, body mass index, time of infection with HIV, presence of comorbidities, CD4(+) T lymphocyte count, total cholesterol and fractions, and triglyceride levels. There was no significant difference in vitamin A or beta-carotene concentrations in patients under the different HAART regimens. However, approximately 4% of the patients had deficient/low concentrations of vitamin A (<0.70 μmol/L), and 98% showed concentrations of beta-carotene <1.0 μmol/L. In conclusion, HIV/AIDS patients in this region will not benefit from vitamin A supplementation, independently of the HAART regimen utilized, but beta-carotene may be of importance, considering its antioxidant effect.

  1. Gross-Motor Skill Acquisition by Preschool Dance Students under Self-Instruction Procedures

    Science.gov (United States)

    Vintere, Parsla; Hemmes, Nancy S.; Brown, Bruce L.; Poulson, Claire L.

    2004-01-01

    The effects of two training procedures -- (a) modeling and praise and (b) self-instruction, modeling, and praise -- on complex gross-motor chain acquisition for preschool dance class students were evaluated. Six girls participated in the study. A multiple baseline design across six gross-motor chains with a secondary group comparison for treatment…

  2. The radioactive equilibrium and determination methods for ratio e Ra/U; Desequilibrio Radiactivos-1. Metodo {sub {beta}}-{gamma}. Determinacion de la razon eRa/U. Valoracion del contenido en U{sub 3}O{sub 8}

    Energy Technology Data Exchange (ETDEWEB)

    Mingarro, E

    1966-07-01

    The main problems concerning the radioactive non-equilibrium on minerals and a simultaneous counting procedure for {beta}- and {gamma}- activities developed to solve those problems, are described. (Author)

  3. Verification of a simple method to achieve alpha/beta separation in LSC for the case of urine samples

    International Nuclear Information System (INIS)

    Oestergren, Inger; Norrlid, Lilian; Wallberg, Lena

    2008-01-01

    Full text: As a part of the national Swedish network of laboratories in emergency response and preparedness, the radio-analytical laboratory of the Swedish Radiation Protection Authority (SSI) should provide with fast and reliable measurements. To this purpose, Liquid Scintillation Counting (LSC) offers the advantages of reduced time for sample preparation, zero sample self-absorption, simultaneously measurement of alpha and beta emitters and high efficiency. The LSC detection system at SSI is a Quantulus 1220, which is a system permitting pulses produced by alpha and beta radiation to be discriminated when adjusting the software parameter Pulse Shape Analysis (PSA). Previously, different authors have found that the dependency of the optimum PSA on scintillation/vial combination is negligible in front of the strong influence of the sample quenching. Also the optimum PSA parameter is found according to each sample quench level, so as the composition of a standard and a real sample should be as close as possible. When handling samples of variable quenching levels, like for example urine, two possibilities have been suggested: 1) To determine the degree of quench in a short count of the samples and then use individual optimum PSA for each sample counting protocol; or 2) To have alpha and beta standards equivalent in quenching to the least quenched sample, determine PSA and quench the standards progressively. Then the percent of total interference is obtained as a function of the quench parameter for a single PSA setting, which permits the samples to be counted with the same protocol and a correction for interference can be applied afterwards. The case of urine is interesting since it is 95 % water but it may contain traces of amino acids and varying amounts of electrolytes, depending upon dietary intake. In this paper we applied number 2. The standards have been quenched to simulate human urine quench levels. The aim is to obtain the look-up table for the percent of

  4. Rapid synthesis of beta zeolites

    Science.gov (United States)

    Fan, Wei; Chang, Chun -Chih; Dornath, Paul; Wang, Zhuopeng

    2015-08-18

    The invention provides methods for rapidly synthesizing heteroatom containing zeolites including Sn-Beta, Si-Beta, Ti-Beta, Zr-Beta and Fe-Beta. The methods for synthesizing heteroatom zeolites include using well-crystalline zeolite crystals as seeds and using a fluoride-free, caustic medium in a seeded dry-gel conversion method. The Beta zeolite catalysts made by the methods of the invention catalyze both isomerization and dehydration reactions.

  5. Active-site-directed inactivation of Aspergillus oryzae beta-galactosidase with beta-D-galactopyranosylmethyl-p-nitrophenyltriazene.

    Science.gov (United States)

    Mega, T; Nishijima, T; Ikenaka, T

    1990-04-01

    beta-D-Galactopyranosylmethyl-p-nitrophenyltriazene (beta-GalMNT), a specific inhibitor of beta-galactosidase, was isolated as crystals by HPLC and its chemical and physicochemical characteristics were examined. Aspergillus oryzae beta-galactosidase was inactivated by the compound. We studied the inhibition mechanism in detail. The inhibitor was hydrolyzed by the enzyme to p-nitroaniline and an active intermediate (beta-galactopyranosylmethyl carbonium or beta-galactopyranosylmethyldiazonium), which inactivated the enzyme. The efficiency of inactivation of the enzyme (the ratio of moles of inactivated enzyme to moles of beta-GalMNT hydrolyzed by the enzyme) was 3%; the efficiency of Escherichia coli beta-galactosidase was 49%. In spite of the low efficiency, the rate of inactivation of A. oryzae enzyme was not very different from that of the E. coli enzyme, because the former hydrolyzed beta-GalMNT faster than the latter did. A. oryzae beta-galactosidase was also inactivated by p-chlorophenyl, p-tolyl, and m-nitrophenyl derivatives of beta-galactopyranosylmethyltriazene. However, E. coli beta-galactosidase was not inactivated by these triazene derivatives. The results showed that the inactivation of A. oryzae and E. coli beta-galactosidases by beta-GalMNT was an enzyme-activated and active-site-directed irreversible inactivation. The possibility of inactivation by intermediates produced nonenzymatically was ruled out for E. coli, but not for the A. oryzae enzyme.

  6. Analysis of historical gross gamma logging data from BX tank farm

    International Nuclear Information System (INIS)

    MYERS, D.A.

    1999-01-01

    Gross gamma ray logs, recorded from January 1975 through mid-year 1994 as part of the Single-Shell Tank Farm Dry Well Surveillance Program, have been reanalyzed for the BX tank farm to locate the presence of mobile radionuclides in the subsurface. This report presents the BX tank farm gross gamma ray data in such a way as to assist others in their study of vadose zone mechanism

  7. Trained, generalized, and collateral behavior changes of preschool children receiving gross-motor skills training.

    OpenAIRE

    Kirby, K C; Holborn, S W

    1986-01-01

    Three preschool children participated in a behavioral training program to improve their gross-motor skills. Ten target behaviors were measured in the training setting to assess direct effects of the program. Generalization probes for two gross-motor behaviors, one fine-motor skill, and two social behaviors were conducted in other settings. Results indicated that the training program improved the gross-motor skills trained and that improvements sometimes generalized to other settings. Contrary...

  8. Maternal plasma concentrations of beta-lipotrophin, beta-endorphin and gamma-lipotrophin throughout pregnancy.

    Science.gov (United States)

    Browning, A J; Butt, W R; Lynch, S S; Shakespear, R A

    1983-12-01

    Plasma beta-LPH, beta-EP and gamma-LPH concentrations were measured by radioimmunoassay in 10 pregnant women from 12 weeks gestation until term and in nine women in the early follicular phase of the cycle. There was a progressive and significant rise in the concentration of all three peptides throughout pregnancy and by 32 weeks the concentrations of beta-LPH and beta-EP were greater than the corresponding concentrations in the follicular phase: gamma-LPH was greater than in the follicular phase by the end of pregnancy in those women who were delivered after 40 weeks. The ratio of beta-LPH to gamma-LPH did not change significantly throughout pregnancy, but there was a progressive fall in the beta-LPH/beta-EP ratio. The possible presence of a 'big LPH' to explain this finding is discussed.

  9. $\\beta$-decay and $\\beta$-delayed Neutron Emission Measurements at GSI-FRS Beyond N=126, for r-process Nucleosynthesis

    CERN Document Server

    Caballero-Folch, R; Cortès, G; Taín, J L; Agramunt, J; Algora, A; Ameil, F; Ayyad, Y; Benlliure, J; Bowry, M; Calviño, F; Cano-Ott, D; Davinson, T; Dillmann, I; Estrade, A; Evdokimov, A; Faestermann, T; Farinon, F; Galaviz, D; García-Ríos, A; Geissel, H; Gelletly, W; Gernhäuser, R; Gómez-Hornillos, M B; Guerrero, C; Heil, M; Hinke, C; Knöbel, R; Kojouharov, I; Kurcewicz, J; Kurz, N; Litvinov, Y; Maier, L; Marganiec, J; Marta, M; Martínez, T; Montes, F; Mukha, I; Napoli, D R; Nociforo, C; Paradela, C; Pietri, S; Podolyák, Zs; Prochazka, A; Rice, S; Riego, A; Rubio, B; Schaffner, H; Scheidenberger, C; Smith, K; Sokol, E; Steiger, K; Sun, B; Takechi, M; Testov, D; Weick, H; Wilson, E; Winfield, J S; Wood, R; Woods, P J; Yeremin, A

    2014-01-01

    New measurements of very exotic nuclei in the neutron-rich region beyond N=126 have been performed at the GSI facility with the fragment separator (FRS). The aim of the experiment is to determine half-lives and beta-delayed neutron emission branching ratios of isotopes of Hg, Tl and Pb in this region. This contribution summarizes final counting statistics for identification and for implantation, as well as the present status of the data analysis of the half-lives. In summary, isotopes of Pt, Au, Hg, Ti, Pb, Bi, Po, At, Rn and Fr were clearly identified and several of them (Hg208-211, Tl211-215, Pb214-218) were implanted with enough statistics to determine their half-lives. About half of them are expected to be neutron emitters, in such cases it will become possible to obtain the neutron emission probabilities, P-n.

  10. Modeling of the Gross Regional Product on the Basis of Production Functions

    Science.gov (United States)

    Sadovin, Nikolay S.; Kokotkina, Tatiana N.; Barkalova, Tatiana G.; Tsaregorodsev, Evgeny I.

    2016-01-01

    The article is devoted to elaboration and construction of a static model of macroeconomics in which economics is considered as an unstructured holistic unit, the input of which receives the resources, and the output is the result of the functioning of economics in the form of gross domestic product or gross regional product. Resources are…

  11. Optimized formation of detergent micelles of beta-carotene and retinal production using recombinant human beta,beta-carotene 15,15'-monooxygenase.

    Science.gov (United States)

    Kim, Nam-Hee; Kim, Yeong-Su; Kim, Hye-Jung; Oh, Deok-Kun

    2008-01-01

    The formation of beta-carotene detergent micelles and their conversion into retinal by recombinant human beta,beta-carotene 15,15'-monooxygenase was optimized under aqueous conditions. Toluene was the most hydrophobic among the organic solvents tested; thus, it was used to dissolve beta-carotene, which is a hydrophobic compound. Tween 80 was selected as the detergent because it supported the highest level of retinal production among all of the detergents tested. The maximum production of retinal was achieved in detergent micelles containing 200 mg/L of beta-carotene and 2.4% (w/v) Tween 80. Under these conditions, the recombinant enzyme produced 97 mg/L of retinal after 16 h with a conversion yield of 48.5% (w/w). The amount of retinal produced, which is the highest ever reported, is a result of the ability of our system to dissolve large amounts of beta-carotene.

  12. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  13. Controls on gross fluxes of nitrous oxide and methane from an active agricultural ecosystem

    Science.gov (United States)

    Yang, W. H.; Silver, W. L.

    2013-12-01

    Agricultural soils can be a significant source of greenhouse gas emissions. Most research on the dynamics of these gases measure net fluxes across the soil-atmosphere interface. This approach limits our ability to determine driving variables because production and consumption processes occur simultaneously, and may be controlled by different factors. We used the trace gas stable isotope pool dilution technique to simultaneously measure field rates of gross production and consumption of N2O and CH4 during the growing season in a corn field located in the Sacramento-San Joaquin Delta, California. We also measured net nitrogen (N) mineralization and nitrification rates, soil temperature, soil moisture, and soil carbon dioxide (CO2) emissions to explore their role as drivers of greenhouse gas fluxes. Across five sampling dates spanning from seeding to senescence, net N2O fluxes ranged from 0 - 4.5 mg N m-2 d-1 and averaged 1.6 × 0.2 mg N m-2 d-1 (n = 112). Gross N2O production ranged from 0.09 - 6.6 mg N m-2 d-1 and gross N2O reduction rates ranged from 0.00 - 0.95 mg N m-2 d-1. The N2O yield averaged 0.68 × 0.02 (n = 40). At peak growth (days after seeding 59 and 94), 89 % of the variability in gross N2O production rates was predicted by the combination of soil moisture, soil temperature, net N mineralization, and CO2 emissions (n = 15, p seeding 11, 24, and 171), gross N2O production was most strongly correlated with soil temperature (R2 = 0.20, n = 24, p = 0.03), and gross N2O reduction rates were best predicted by CO2 emissions (R2 = 0.80, n =24, p production in 36 out of 37 measurements. Gross CH4 production reached as high as 5.4 mg C m-2 d-1 with rates trending higher throughout the growing season. Gross CH4 production rates were marginally significantly higher in rows than in inter-rows (p = 0.10). Gross CH4 oxidation did not differ significantly among sampling dates (Figure 2b), averaging 1.1 × 0.2 mg C m-2 d-1 across all measurements (n = 37). However

  14. Removal of radionuclides in drinking water by membrane treatment using ultrafiltration, reverse osmosis and electrodialysis reversal

    International Nuclear Information System (INIS)

    Montaña, M.; Camacho, A.; Serrano, I.; Devesa, R.; Matia, L.; Vallés, I.

    2013-01-01

    A pilot plant had been built to test the behaviour of ultrafiltration (UF), reverse osmosis (RO), and electrodialysis reversal (EDR) in order to improve the quality of the water supplied to Barcelona metropolitan area from the Llobregat River. This paper presents results from two studies to reduce natural radioactivity. The results from the pilot plant with four different scenarios were used to design the full-scale treatment plant built (SJD WTP). The samples taken at different steps of the treatment were analysed to determine gross alpha, gross beta and uranium activity. The results obtained revealed a significant improvement in the radiological water quality provided by both membrane techniques (RO and EDR showed removal rates higher than 60%). However, UF did not show any significant removal capacity for gross alpha, gross beta or uranium activities. RO was better at reducing the radiological parameters studied and this treatment was selected and applied at the full scale treatment plant. The RO treatment used at the SJD WTP reduced the concentration of both gross alpha and gross beta activities and also produced water of high quality with an average removal of 95% for gross alpha activity and almost 93% for gross beta activity at the treatment plant. -- Highlights: ► A study with a pilot plant using different membranes technologies was made. ► Big reduction on natural uranium and 40 K by reverse osmosis was found. ► Pilot plant and full-scale treatment plant behave similarly

  15. Beta cell adaptation in pregnancy

    DEFF Research Database (Denmark)

    Nielsen, Jens Høiriis

    2016-01-01

    Pregnancy is associated with a compensatory increase in beta cell mass. It is well established that somatolactogenic hormones contribute to the expansion both indirectly by their insulin antagonistic effects and directly by their mitogenic effects on the beta cells via receptors for prolactin...... and growth hormone expressed in rodent beta cells. However, the beta cell expansion in human pregnancy seems to occur by neogenesis of beta cells from putative progenitor cells rather than by proliferation of existing beta cells. Claes Hellerström has pioneered the research on beta cell growth for decades...... in the expansion of the beta cell mass in human pregnancy, and the relative roles of endocrine factors and nutrients....

  16. Data Reconciliation and Gross Error Detection for Troubleshooting of Ammonia Reactor

    Directory of Open Access Journals (Sweden)

    Adhi Tri Partono

    2018-01-01

    Full Text Available Data reconciliation (DR and gross error detection are two common tools used in industry to provide accurate and reliable data, which is useful to analyse plant performance and basis for troubleshooting. DR techniques improve the accuracy of measurements by using redundancies in material and energy balances. This provides reliable information that could help decision making regarding plant operation, which potentially leads to financial benefit. This paper presents the utilization of plant data to perform troubleshooting of ammonia reactor, in particular the profile of catalyst activity. Bad plant data are collected and then analysed using DR to produces reconciled data, which could be used to detect and identify the gross error measurements. The input data for DR and gross error detection were gathered from Aspen HYSYS V8.8 simulations by modelling the single-bed ammonia reactor. The result presents that bad plant data could define actual system condition such as gross error measurements in normal condition or catalyst activity problem. Both conditions are modelled by DR to indicate actual system condition using statistical analysis and to perform troubleshooting. Appropriate troubleshooting could save time and provide financial benefits by avoiding wrong accusation of system problem, specifically in ammonia reactor evaluated in this paper.

  17. Factors Associated with Enhanced Gross Motor Progress in Children with Cerebral Palsy: A Register-Based Study.

    Science.gov (United States)

    Størvold, Gunfrid V; Jahnsen, Reidun B; Evensen, Kari Anne I; Romild, Ulla K; Bratberg, Grete H

    2018-05-01

    To examine associations between interventions and child characteristics; and enhanced gross motor progress in children with cerebral palsy (CP). Prospective cohort study based on 2048 assessments of 442 children (256 boys, 186 girls) aged 2-12 years registered in the Cerebral Palsy Follow-up Program and the Cerebral Palsy Register of Norway. Gross motor progress estimates were based on repeated measures of reference percentiles for the Gross Motor Function Measure (GMFM-66) in a linear mixed model. Mean follow-up time: 2.9 years. Intensive training was the only intervention factor associated with enhanced gross motor progress (mean 3.3 percentiles, 95% CI: 1.0, 5.5 per period of ≥3 sessions per week and/or participation in an intensive program). Gross motor function was on average 24.2 percentiles (95% CI: 15.2, 33.2) lower in children with intellectual disability compared with others. Except for eating problems (-10.5 percentiles 95% CI: -18.5, -2.4) and ankle contractures by age (-1.9 percentiles 95% CI: -3.6, -0.2) no other factors examined were associated with long-term gross motor progress. Intensive training was associated with enhanced gross motor progress over an average of 2.9 years in children with CP. Intellectual disability was a strong negative prognostic factor. Preventing ankle contractures appears important for gross motor progress.

  18. Divergence of fine and gross motor skills in prelingually deaf children: implications for cochlear implantation.

    Science.gov (United States)

    Horn, David L; Pisoni, David B; Miyamoto, Richard T

    2006-08-01

    The objective of this study was to assess relations between fine and gross motor development and spoken language processing skills in pediatric cochlear implant users. The authors conducted a retrospective analysis of longitudinal data. Prelingually deaf children who received a cochlear implant before age 5 and had no known developmental delay or cognitive impairment were included in the study. Fine and gross motor development were assessed before implantation using the Vineland Adaptive Behavioral Scales, a standardized parental report of adaptive behavior. Fine and gross motor scores reflected a given child's motor functioning with respect to a normative sample of typically developing, normal-hearing children. Relations between these preimplant scores and postimplant spoken language outcomes were assessed. In general, gross motor scores were found to be positively related to chronologic age, whereas the opposite trend was observed for fine motor scores. Fine motor scores were more strongly correlated with postimplant expressive and receptive language scores than gross motor scores. Our findings suggest a disassociation between fine and gross motor development in prelingually deaf children: fine motor skills, in contrast to gross motor skills, tend to be delayed as the prelingually deaf children get older. These findings provide new knowledge about the links between motor and spoken language development and suggest that auditory deprivation may lead to atypical development of certain motor and language skills that share common cortical processing resources.

  19. Noun Countability; Count Nouns and Non-count Nouns, What are the Syntactic Differences Between them?

    Directory of Open Access Journals (Sweden)

    Azhar A. Alkazwini

    2016-11-01

    Full Text Available Words that function as the subjects of verbs, objects of verbs or prepositions and which can have a plural form and possessive ending are known as nouns. They are described as referring to persons, places, things, states, or qualities and might also be used as an attributive modifier. In this paper, classes and subclasses of nouns shall be presented, then, noun countability branching into count and non-count nous shall be discussed. A number of present examples illustrating differences between count and non-count nouns and this includes determiner-head-co-occurrence restrictions of number, subject-verb agreement, in addition to some exceptions to this agreement rule shall be discussed. Also, the lexically inherent number in nouns and how inherently plural nouns are classified in terms of (+/- count are illustrated. This research will discuss partitive construction of count and non-count nouns, nouns as attributive modifier and, finally, conclude with the fact that there are syntactic difference between count and non-count in the English Language.

  20. Beta spectrometry

    International Nuclear Information System (INIS)

    Dryak, P.; Zderadicka, J.; Plch, J.; Kokta, L.; Novotna, P.

    1977-01-01

    For the purpose of beta spectrometry, a semiconductor spectrometer with one Si(Li) detector cooled with liquid nitrogen was designed. Geometrical detection efficiency is about 10% 4 sr. The achieved resolution for 624 keV conversion electrons of sup(137m)Ba is 2.6 keV (FWHM). A program was written in the FORTRAN language for the correction of the deformation of the measured spectra by backscattering in the analysis of continuous beta spectra. The method permits the determination of the maximum energy of the beta spectrum with an accuracy of +-5 keV. (author)

  1. Comparison of a gross anatomy laboratory to online anatomy software for teaching anatomy.

    Science.gov (United States)

    Mathiowetz, Virgil; Yu, Chih-Huang; Quake-Rapp, Cindee

    2016-01-01

    This study was designed to assess the grades, self-perceived learning, and satisfaction between occupational therapy students who used a gross anatomy laboratory versus online anatomy software (AnatomyTV) as tools to learn anatomy at a large public university and a satellite campus in the mid-western United States. The goal was to determine if equivalent learning outcomes could be achieved regardless of learning tool used. In addition, it was important to determine why students chose the gross anatomy laboratory over online AnatomyTV. A two group, post-test only design was used with data gathered at the end of the course. Primary outcomes were students' grades, self-perceived learning, and satisfaction. In addition, a survey was used to collect descriptive data. One cadaver prosection was available for every four students in the gross anatomy laboratory. AnatomyTV was available online through the university library. At the conclusion of the course, the gross anatomy laboratory group had significantly higher grade percentage, self-perceived learning, and satisfaction than the AnatomyTV group. However, the practical significance of the difference is debatable. The significantly greater time spent in gross anatomy laboratory during the laboratory portion of the course may have affected the study outcomes. In addition, some students may find the difference in (B+) versus (A-) grade as not practically significant. Further research needs to be conducted to identify what specific anatomy teaching resources are most effective beyond prosection for students without access to a gross anatomy laboratory. © 2015 American Association of Anatomists.

  2. Acute radiotherapy toxicity in 57 dogs with gross and microscopic mast cell tumours.

    Science.gov (United States)

    Blackwood, L; Tanis, J B; Harper, A; Amores-Fuster, I; Killick, D R; Finotello, R

    2018-05-15

    Mast cell tumours (MCTs) are commonly treated with radiation therapy, most often in a microscopic disease setting. Poorer outcomes are expected in patients with gross disease, and irradiation of gross disease may be associated with greater toxicity. The aim of this study was to compare acute radiation adverse events (AE) in dogs with gross and microscopic MCTs receiving radiotherapy. Fifty-seven dogs were included, 28 with gross disease and 29 with microscopic. In order to assess mucosal and skin toxicity, patients were assigned to 2 groups: head (29 patients, 14 patients with gross and 15 microscopic) and other sites (28 patients, 14 each). All were treated with external beam radiotherapy, and toxicity assessed at the end of treatment and 10 to 14 days later (first recheck). All patients developed some acute radiation toxicity by the end of the course. However, there was no difference in the severity of toxicity between gross and microscopic disease in either site group at either time point. The only variable associated with an increased frequency of grade 2 or 3 toxicity at the first recheck was the use of prednisolone prior to radiotherapy (P = .05). No other factors were identified which were associated with increased toxicity. For the head group, the site of highest grade toxicity was mucosa or, if included in the field, nasal planum, which was often more severely affected than the mucosa. No significant late toxicity was identified. Two dogs developed acute haematemesis during the radiotherapy course, but both completed the course without further events. © 2018 John Wiley & Sons Ltd.

  3. Natural and Artificial Radioactivity in Drinkingwater in Malaga, Spain

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, M. C.; Duenas, C.; Gordo, E.; Canete, S. [Department of Applied Physics I, Faculty of Science, University of Malaga (Spain); Perez, M. [Department of Radiology and Health Physics, Faculty of Medicine, University of Malaga, Malaga (Spain)

    2013-07-15

    The measurement of radioactivity in drinking water permits us to determine the exposure of the population to radiation from the habitual consumption of water. An intensive study of the water supply in the city of Malaga during 2002-2010 has been carried out in order to determine the gross alpha and gross beta activities and natural and artificial radionuclides present in drinking water. A database on natural and artificial radioactivity in water was created. The results indicated that a high percentage of the water sample contains a total gross alpha and beta concentration of less than 0.10 Bq/L and 1 Bq/L, respectively. The main objectives were: (1) to analyse gross alpha and gross beta activities and to know the statistical distributions; (2) to study the levels of natural and artificial radionuclides; (3) to determine a possible mathematical correlation between the radionuclides and several factors. (author)

  4. Fine and gross motor skills: The effects on skill-focused dual-tasks.

    Science.gov (United States)

    Raisbeck, Louisa D; Diekfuss, Jed A

    2015-10-01

    Dual-task methodology often directs participants' attention towards a gross motor skill involved in the execution of a skill, but researchers have not investigated the comparative effects of attention on fine motor skill tasks. Furthermore, there is limited information about participants' subjective perception of workload with respect to task performance. To examine this, the current study administered the NASA-Task Load Index following a simulated shooting dual-task. The task required participants to stand 15 feet from a projector screen which depicted virtual targets and fire a modified Glock 17 handgun equipped with an infrared laser. Participants performed the primary shooting task alone (control), or were also instructed to focus their attention on a gross motor skill relevant to task execution (gross skill-focused) and a fine motor skill relevant to task execution (fine skill-focused). Results revealed that workload was significantly greater during the fine skill-focused task for both skill levels, but performance was only affected for the lesser-skilled participants. Shooting performance for the lesser-skilled participants was greater during the gross skill-focused condition compared to the fine skill-focused condition. Correlational analyses also demonstrated a significant negative relationship between shooting performance and workload during the gross skill-focused task for the higher-skilled participants. A discussion of the relationship between skill type, workload, skill level, and performance in dual-task paradigms is presented. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. DMPD: Immunoreceptor-like signaling by beta 2 and beta 3 integrins. [Dynamic Macrophage Pathway CSML Database

    Lifescience Database Archive (English)

    Full Text Available 17913496 Immunoreceptor-like signaling by beta 2 and beta 3 integrins. Jakus Z, Fod...) Show Immunoreceptor-like signaling by beta 2 and beta 3 integrins. PubmedID 17913496 Title Immunoreceptor-...like signaling by beta 2 and beta 3 integrins. Authors Jakus Z, Fodor S, Abram CL

  6. Are gross motor skills and sports participation related in children with intellectual disabilities?

    NARCIS (Netherlands)

    Westendorp, Marieke; Houwen, Suzanne; Hartman, Esther; Visscher, Chris

    2011-01-01

    This study compared the specific gross motor skills of 156 children with intellectual disabilities (ID) (50 79) with that of 255 typically developing children, aged 7-12 years. Additionally, the relationship between the specific gross motor skills and organized sports participation was examined

  7. Identification of active anti-inflammatory principles of beta- beta ...

    African Journals Online (AJOL)

    chromatography. Components of the extracts were identified by thin layer chromatography (TLC) scanner and UV-visible spectroscopy, using scopoletin as standard. Results: ... basic coumarin skeleton ring structure reduce ... Figure 2: Thin-layer chromatogram: (1) Ethanol extract; (2) Dichloromethane fraction; (3) Beta-beta.

  8. Solitons in Gross-Pitaevskii equation

    International Nuclear Information System (INIS)

    Lopes, E.

    1985-01-01

    It is observed that, when the potential is integrable and repulsive, the Gross-Pitaevskii Equation, with non-vanishing boundary conditions, describes a family of planar solitons. A method is presented which provides an exact soliton field to the Dirac Delta potential and an approximation solution to any other kind of potential. As an example the method is then applied to the case of a repulsive Yukawa potential. A brief discuss the relation between these solitons and Anderson's superfluidity mechanism, is also presented. (author) [pt

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  10. Use of a Radon Stripping Algorithm for Retrospective Assessment of Air Filter Samples

    International Nuclear Information System (INIS)

    Hayes, Robert

    2009-01-01

    An evaluation of a large number of air sample filters was undertaken using a commercial alpha and beta spectroscopy system employing a passive implanted planar silicon (PIPS) detector. Samples were only measured after air flow through the filters had ceased. Use of a commercial radon stripping algorithm was implemented to discriminate anthropogenic alpha and beta activity on the filters from the radon progeny. When uncontaminated air filters were evaluated, the results showed that there was a time-dependent bias in both average estimates and measurement dispersion with the relative bias being small compared to the dispersion. By also measuring environmental air sample filters simultaneously with electroplated alpha and beta sources, use of the radon stripping algorithm demonstrated a number of substantial unexpected deviations. Use of the current algorithm is therefore not recommended for assay applications and so use of the PIPS detector should only be utilized for gross counting without appropriate modifications to the curve fitting algorithm. As a screening method, the radon stripping algorithm might be expected to see elevated alpha and beta activities on air sample filters (not due to radon progeny) around the 200 dpm level

  11. The new energy management policy: Indonesian PSC-gross-split applied on steam flooding project

    Science.gov (United States)

    Irham, S.; Julyus, P.

    2018-01-01

    “SIPY” oil field has been producing oil using steam flooding technology since 1992 under the PSC-Cost-Recovery policy. In 2021, the contract will be finished, and a new agreement must be submitted to the Indonesian government. There are two applied fiscal policies on oil and gas management: PSC-Cost-Recovery and PSC-Gross-Split (introduced in 2017 as the new energy management plan). The contractor must choose between PSC-Cost-Recovery and PSC-Gross-split which makes more profit. The aim of this research is to determine the best oil and gas contract policy for the contractor. The methods are calculating contractor cash flow and comparing the Profitability Indexes. The results of this study are (1) Net Present Values for the PSC-Cost-Recovery and the PSC-Gross-Split are 15 MMUS and 61 MMUS, respectively; and (2) Internal Rate of Return values for the PSC-Cost-Recovery and PSC-Gross-Split are 10% and 11%, respectively. The conclusion is that the Net Present Value and Internal Rate of Return of PSC-Gross-Split are greater than those of PSC-Cost-Recovery, but in Pay Out Time of PSC-Gross-split is longer than Pay Out Time in PSC-Cost-Recovery. Thus, the new energy management policy will be more attractive than PSC-Cost-Recovery.

  12. The new management policy: Indonesian PSC-Gross split applied on CO2 flooding project

    Science.gov (United States)

    Irham, S.; Sibuea, S. N.; Danu, A.

    2018-01-01

    “SIAD” oil field will be developed by CO2 flooding. CO2, a famous pollutant gas, is injected into the oil reservoir to optimize the oil recovery. This technique should be conducted economically according to the energy management policy in Indonesia. In general, Indonesia has two policy contracts on oil and gas: the old one is PSC-Cost-Recovery, and the new one is PSC-Gross-Split (introduced in 2017 as the new energy management plan). The contractor must choose between PSC-Cost-Recovery and PSC-Gross-Split which makes more profit. The aim of this paper is to show the best oil and gas contract policy for the contractor. The methods are calculating and comparing the economic indicators. The result of this study are (1) NPV for the PSC-Cost-Recovery is -46 MUS, while for the PSC-Gross-Split is 73 MUS, and (2) IRR for the PSC-Cost-Recovery is 9%, whereas for the PSC-Gross-Split is 11%. The conclusion is that the NPV and IRR for PSC-Gross-Split are greater than the NPV and IRR of PSC-Cost-Recovery, but POT in PSC-Gross-split is longer than POT in PSC-Cost-Recovery. Thus, in this case, the new energy policy contract can be applied for CO2 flooding technology since it yields higher economic indicators than its antecendent.

  13. Dimers of beta 2-glycoprotein I mimic the in vitro effects of beta 2-glycoprotein I-anti-beta 2-glycoprotein I antibody complexes

    NARCIS (Netherlands)

    Lutters, B. C.; Meijers, J. C.; Derksen, R. H.; Arnout, J.; de Groot, P. G.

    2001-01-01

    Anti-beta(2)-glycoprotein I antibodies are thought to cause lupus anticoagulant activity by forming bivalent complexes with beta(2)-glycoprotein I (beta(2)GPI). To test this hypothesis, chimeric fusion proteins were constructed of the dimerization domain (apple 4) of factor XI and beta(2)GPI. Both a

  14. Exercise- and cold-induced changes in plasma beta-endorphin and beta-lipotropin in men and women.

    Science.gov (United States)

    Viswanathan, M; Van Dijk, J P; Graham, T E; Bonen, A; George, J C

    1987-02-01

    The plasma beta-endorphin (beta-EP) and beta-lipotropin (beta-LPH) response of men, eumenorrheic women, and amenorrheic women (n = 6) to 1 h of rest or to a bicycle ergometer test [20 min at 30% maximum O2 uptake (VO2max), 20 min at 60% VO2max, and at 90% VO2max to exhaustion] was studied in both normal (22 degrees C) and cold (5 degrees C) environments. beta-EP and beta-LPH was measured by radioimmunoassay in venous samples collected every 20 min during rest or after each exercise bout. Exhaustive exercise at ambient temperature (Ta) 22 degrees C induced significant increases in plasma beta-EP and beta-LPH in all subjects as did work at 60% VO2max in amenorrheic and eumenorrheic women. During work at Ta 5 degrees C, the relative increase in beta-EP and beta-LPH was suppressed in eumenorrheic women and completely prevented in amenorrheic women. Although significant lowering of beta-EP and beta-LPH was observed in men and eumenorrheic women during rest at 5 degrees C, amenorrheic women maintained precold exposure levels. These findings suggest that plasma beta-EP and beta-LPH may reflect a thermoregulatory response to heat load. There appears to be a sexual dimorphism in exercise- and cold-induced release of beta-EP and beta-LPH and amenorrhea may be accompanied by alterations in these responses.

  15. Gross efficiency and energy expenditure in kayak ergometer exercise.

    Science.gov (United States)

    Gomes, B B; Mourão, L; Massart, A; Figueiredo, P; Vilas-Boas, J P; Santos, A M C; Fernandes, R J

    2012-08-01

    We purposed to study energy expenditure, power output and gross efficiency during kayak ergometer exercise in 12 elite sprint kayakers. 6 males (age 24.2±4.8 years, height 180.4±4.8 cm, body mass 79.7±8.5 kg) and 6 females (age 24.3±4.5 years, height 164.5±3.9 cm, body mass 65.4±3.5 kg), performed an incremental intermittent protocol on kayak ergometer with VO2 and blood lactate concentration assessment, a non-linear increase between power output and energy expenditure being observed. Paddling power output, energy expenditure and gross efficiency corresponding to VO2max averaged 199.92±50.41 W, 75.27±6.30 ml.kg - 1.min - 1, and 10.10±1.08%. Male kayakers presented higher VO2max, power output and gross efficiency at the VO2max, and lower heart rate and maximal lactate concentration than females, but no differences were found between genders regarding energy expenditure at VO2max. Aerobic and anaerobic components of energy expenditure evidenced a significant contribution of anaerobic energy sources in sprint kayak performance. Results also suggested the dependence of the gross efficiency on the changes in the amount of the aerobic and anaerobic contributions, at heavy and severe intensities. The inter-individual variance of the relationship between energy expenditure and the corresponding paddling power output revealed a relevant tracking for females (FDγ=0.73±0.06), conversely to the male group (FDγ=0.27±0.08), supporting that some male kayakers are more skilled in some paddling intensities than others. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... 03. R Mayer 371,490 views 4:03 The psychological trick behind getting people to say yes - Duration: 8:06. PBS NewsHour 606,671 views 8:06 Should You Really Wash Your Hands? - Duration: 4:51. Gross Science 57,828 views 4:51 Healthcare Worker Hand ...

  17. Count-to-count time interval distribution analysis in a fast reactor

    International Nuclear Information System (INIS)

    Perez-Navarro Gomez, A.

    1973-01-01

    The most important kinetic parameters have been measured at the zero power fast reactor CORAL-I by means of the reactor noise analysis in the time domain, using measurements of the count-to-count time intervals. (Author) 69 refs

  18. beta-Thalassemia present in cis to a new beta-chain structural variant, Hb Vicksburg [beta 75 (E19)Leu leads to 0].

    Science.gov (United States)

    Adams, J G; Steinberg, M H; Newman, M V; Morrison, W T; Benz, E J; Iyer, R

    1981-01-01

    Hemoglobin Vicksburg was discovered in a 6-year-old Black boy who had been anemic since infancy. Examination of his hemolysate revealed 87.5% Hb F, 2.4% Hb A2, and 7.6% Hb Vicksburg, which had the electrophoretic and chromatographic properties of Hb A. Structural analysis of Hb Vicksburg demonstrated a deletion of leucine at beta 75(E19), a new variant. Hb Vicksburg was neither unstable nor subject to posttranslational degradation. The alpha/non-alpha biosynthetic ratio was 2.6. Because the proband appeared to be a mixed heterozygote for Hb Vicksburg and beta 0-thalassemia, Hb Vicksburg should have comprised the major portion of the hemolysate. Thus, Hb Vicksburg was synthesized at a rate considerably lower than would be expected on the basis of gene dosage. There was no reason to suspect abnormal translation of beta Vicksburg mRNA; in individuals with Hb St. Antoine (beta 74 and beta 75 deleted), the abnormal hemoglobin comprised 25% of the hemolysate in the simple heterozygote yet was unstable. Deletion of beta 75, therefore, would not in itself appear to lead to diminished synthesis. There was a profound deficit of beta Vicksburg mRNA when measured by liquid hybridization analysis with beta cDNA. The most plausible explanation for the low output of Hb Vicksburg is that a mutation for beta +-thalassemia is present in cis to the structural mutation.

  19. Jatropha curcas – Analysis of Gross Calorific Value

    Directory of Open Access Journals (Sweden)

    Juraj Ružbarský

    2014-01-01

    Full Text Available In recent years biofuels have obtained a considerable interest, due to the implementation of ruling and gradual replacement of fossil fuels. One of production steps at gaining the oil is a pressing process. Wastes come into being from this process. These wastes are used as feed, fertilizer prospectively as fuel. A contemporary scientific literature pays attention namely to one of prospective produces which is a produce of the tropical and subtropical zones Jatropa curcas. Tests were performed at Jatropha Curcas seeds of a brown colour (that means gnaw. The aim of a research is an analysis of Jatropa curcas seed from the utilization point of view of the gross calorific value. The basic instrument to evaluate the gross calorific value of each variant of the experiment was a calorimeter PARR 6200 and digital scales for accurate laboratory weighing.

  20. Clusters of conserved beta cell marker genes for assessment of beta cell phenotype

    DEFF Research Database (Denmark)

    Martens, Geert A; Jiang, Lei; Hellemans, Karine H

    2011-01-01

    The aim of this study was to establish a gene expression blueprint of pancreatic beta cells conserved from rodents to humans and to evaluate its applicability to assess shifts in the beta cell differentiated state. Genome-wide mRNA expression profiles of isolated beta cells were compared to those...... of a large panel of other tissue and cell types, and transcripts with beta cell-abundant and -selective expression were identified. Iteration of this analysis in mouse, rat and human tissues generated a panel of conserved beta cell biomarkers. This panel was then used to compare isolated versus laser capture...

  1. Determination of 131mXe and 133mXe in the presence of 133gXe via combined beta-spectroscopy and delayed coincidence

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; McIntyre, J.I.; Pitts, W.K.

    2001-01-01

    The International Monitoring System for the Comprehensive Nuclear-Test-Ban Treaty will include measurements of Xe fission products. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which detects Xe fission products using a beta-gamma counting system for 131m Xe, 133m Xe, 133g Xe, and 135g Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse-height spectra of gamma-energy versus beta-energy are obtained. The plastic scintillator spectrum in coincidence with the 31-keV X-rays from 131m Xe. 133m Xe, and 133g Xe is a complex mixture of conversion electrons and betas. A new technique to simultaneously measure the delayed coincidence (T 1/2 = 6.27 ns) between beta-particles from 133g Xe and conversion electrons depopulating the 81-keV state in 133 Cs is being developed. This technique allows separation of the 133g Xe beta spectrum from the conversion electrons due to 131m Xe and 133m Xe and uniquely quantifies all three nuclides. (author)

  2. beta-Carotene in breast milk and serum is increased after a single beta-carotene dose.

    Science.gov (United States)

    Canfield, L M; Giuliano, A R; Neilson, E M; Yap, H H; Graver, E J; Cui, H A; Blashill, B M

    1997-07-01

    Normal lactating mothers were administered a single dose of 60 or 210 mg beta-carotene and changes in serum and milk retinol, alpha-tocopherol, and carotenoids were monitored for 8 d. Average serum beta-carotene concentrations increased 4.1- and 4.0-fold after the 60- and 210-mg doses, respectively. Milk beta-carotene concentrations increased 4.1- and 3.0-fold after the 60- and 210-mg doses, respectively. Maximum serum concentrations were reached 24 h after both supplements, although concentrations of milk beta-carotene continued to rise for 2-3 d. After 8 d, both serum and milk beta-carotene continued to rise for 2-3 d. After 8 d, both serum and milk beta-carotene concentrations remained about twofold higher than baseline concentrations. Increases in serum or milk beta-carotene concentrations were not dose-dependent. Initial serum and milk concentrations of beta-carotene predicted increases after supplementation, and increases in serum beta-carotene concentrations predicted those in milk. Concentrations of milk carotenoids were less than one-tenth their respective concentrations in serum. Lutein, beta-cryptoxanthin, lycopene, alpha-carotene, retinol, and alpha-tocopherol concentrations in serum or milk did not change significantly after beta-carotene supplementation. Retinol esters account for most of the retinol equivalents in the milk of well-nourished mothers. Initial and maximum concentrations of beta-carotene in serum and milk were strongly correlated for individual mothers. Collectively, the data showed that a single 60-mg supplement of beta-carotene sustained elevated beta-carotene concentrations in serum and milk for > 1 wk in normal mothers but did not affect concentrations of other major carotenoids, retinol, or alpha-tocopherol.

  3. TRIATHLER: modern and mobile LSC instrument for the detection of radon and other radionuclides in water

    International Nuclear Information System (INIS)

    Frenzel, E.

    2004-01-01

    Rapid and sensitive measurements of radon in water and in drinking water is done with various methods. Liquid Scintillation Counting (LSC) is one of the best and most sensitive methods. This technique is international agreed and accepted. Now, for some years with Triathler(TM) a compact and mobile liquid scintillation counter is available. The Triathler with integrated alpha/beta separation enables both laboratory and in situ measurements of 222 Rn in water (LLoD 222 Rn in water are possible. In addition with simple chemical steps other natural occurring radionuclides can be measured. Due to European regulations, drinking water has to be monitored regarding the 0.1 mSv concept. With Triathler it is possible according to the method of L. Salonen and the modification by S. Wisser, to detect gross alpha activities 222 Rn in water (extractive and non-extractive methods); 234 U/ 238 U in water (extraction of U via modified cocktails); 226 Ra (enrichment by filtering on special 3M RadDisks); 228 Ra (enrichment by filtering on special 3M RadDisks); alpha-gross counting. The special rapid method for 226 Ra and 228 Ra takes benefit of the element-selective filters of 3M. These filters were developed by US research centers (like the Argonne National Laboratories) together with 3M. Up to 5 liters are filtered through the RadDisks and afterwards measured preferable by LSC, or Low Background Counting or gamma spectroscopy. (author)

  4. Beta Thalassemia (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Beta Thalassemia KidsHealth / For Parents / Beta Thalassemia What's in this ... Symptoms Diagnosis Treatment Print en español Beta talasemia Thalassemias Thalassemias are a group of blood disorders that ...

  5. The Performance of Fundamental Gross Motor Skills by Children Enrolled in Head Start.

    Science.gov (United States)

    Woodard, Rebecca J.; Yun, Joonkoo

    2001-01-01

    This study sought to descriptively evaluate the performance of fundamental gross motor skills among Head Start children. Levels of performance were compared and contrasted with performance profiles of the Test of Gross Motor Development. Findings suggest that Head Start curriculum should focus on the importance of developing fundamental gross…

  6. Beta-Adrenergic Blockade Does not Prevent Polycythemia or Decrease in Plasma Volume in Men at 4300 m Altitude

    Science.gov (United States)

    Grover, R. F.; Selland, M. A.; McCullough, R. G.; Dahms, T. E.; Wolfel, E. E.; Butterfield, G. E.; Reeves, J. T.; Greenleaf, J. E.

    1998-01-01

    When humans ascend to high altitude (ALT) their plasma volume (PV) and total blood volume (BV) decrease during the first few days. With continued residence over several weeks, the hypoxia-induced stimulation of erythropoietin increases red cell production which tends to restore BV. Because hypoxia also activates the beta-adrenergic system, which stimulates red blood cell production, we investigated the effect of adrenergic beta-receptor inhibition with propranolol on fluid volumes and the polycythemic response in 11 healthy unacclimatized men (21-33 years old exposed to an ALT of 4300 m (barometric pressure 460 Torr) for 3 weeks on Pikes Peak, Colorado. PV was determined by the Evans blue dye method (PV(sub EB)), BV by the carbon monoxide method (BV(sub CO)), red cell volume (RCV)was calculated from hematocrit (Hct) and BV(sub CO), and serum erythropoietin concentration ([EPO]) and reticulocyte count, were also determined. All determinations were made at sea level and after 9-11 (ALT-10) and 9-20 (ALT-20) days at ALT. At sea level and ALT, six men received propranolol (pro, 240 mg/day), and five received a placebo (pla). Effective beta-blockade did not modify the mean (SE) maximal values of [EPO] [pla: 24.9 (3.5) vs pro: 24.5 (1.5) mU/ml] or reticulocyte count [pla: 2.7 (0.7) vs pro: 2.2 (0.5)%]; nor changes in PV(sub EB)[pla: -15.8 (3.8) vs pro: -19.9 (2.8)%], RCV(sub CO) [pla: +7.0 (6.7) vs pro: +10.1 (6.1)%], or BV(sub CO) [pla: -7.3 (2.3) vs pro: -7.1 (3.9)%]. In the absence of weight loss, a redistribution of body water with no net loss is implied. Hence, activation of the beta-adrenergic system did not appear to affect the hypovolemic or polycythemic responses that occurred during 3 weeks at 4300 m ALT in these subjects.

  7. Landscape History of Grosses Moos, NW Swiss Alpine Foreland.

    Science.gov (United States)

    Joanna Heer, Aleksandra; Adamiec, Grzegorz; Veit, Heinz; May, Jan-Hendrik; Novenko, Elena; Hajdas, Irka

    2017-04-01

    The western Swiss Plateau with Lake Neuchâtel is part of the alpine foreland and among the key areas for the reconstruction of environmental changes since the last postglacial. This study was carried out in a landscape located NE of the lake and called Grosses Moos (The Large Fen) - currently designated the Swiss largest, continuous farming area, after the fen was drained in course of landscape engineering projects performed in Switzerland at the end of the 19th century. The study contributes new results from nine excavations of littoral ridges identified in Grosses Moos, and integrates sedimentology, paleo-environmental analysis and three independent chronological methods. Radiocarbon dating, pollen analysis and optically stimulated luminescence (OSL) were applied to the sediments. While pollen and radiocarbon follow the standard procedures, the evaluation of the luminescence age estimates demanded adjustment according to the physical and microdosimetric properties of the alpine quartz, and consideration of the peculiarities of the changing littoral environments of Grosses Moos. The Grosses Moos landscape developed on the temporary surface of the post-Last Glacial sedimentary infill of the over-deepened glacial Aare valley. In this study the landscape history has been fitted into the existing supraregional time scales of NGRIP, the Swiss bio-zones system and the human history based on archaeological and historic records and covers a time span of up to 15'000 yr b2k. The wide-ranging suite of geomorphic features and sedimentary sequences, including littoral lake sediments, beach ridges, dunes, palaeo-channels, peat and colluvial deposits, enable the extensive reconstruction of spatially and temporally variable natural shaping processes. In addition, our results indicate remobilization of soil, colluvium, and sediment due to human settlement activities since the Neolithic - with an important increase in sediment load and spatial variability since the Bronze Age

  8. Comparison of iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane for imaging of the dopamine transporter in the living human brain

    Energy Technology Data Exchange (ETDEWEB)

    Kuikka, J.T. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Bergstroem, K.A. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Ahonen, A. [Dept. of Clinical Chemistry, Oulu Univ. Central Hospital (Finland); Hiltunen, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Haukka, J. [MAP Medical Technologies Oy, Tikkakoski (Finland); Laensimies, E. [Dept. of Clinical Physiology, Kuopio Univ. Hospital (Finland); Wang Shaoyin [Research Biochemicals International (RBI), Natick, MA (United States); Neumeyer, J.L. [Research Biochemicals International (RBI), Natick, MA (United States)

    1995-04-01

    Several cocaine congeners are of potential for imaging the dopamine transporter (DAT). Previous studies have shown that iodine-123 labelled 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)tropane ([{sup 123}I]{beta}-CIT) is a promising radiotracer for imaging the serotonin (5-HT) and dopamine (DA) transporters in the living human brain with single-photon emission tomography (SPET). [{sup 123}I]{beta}-CIT was found to be not very practical for 1-day DAT imaging protocols since peak DAT uptake occurs later than 8 h. Here we report a pilot comparison of [{sup 123}I]{beta}-CIT and 2{beta}-carbomethoxy-3{beta}-(4-iodophenyl)-N-(3-fluoropropyl)nortropane ([{sup 123}I]{beta}-CIT-FP), using SPET imaging in four healthy male subjects. Peak uptake of [{sup 123}I]{beta}-CIT-FP into the basal ganglia occurred earlier (3-4 h after injection of tracer) than that of [{sup 123}I]{beta}-CIT (>8 h). However, the specific DAT binding of [{sup 123}I]{beta}-CIT-FP in the basal ganglia was somewhat less (0.813{+-}0.047) than that of [{sup 123}I]{beta}-CIT (0.922{+-}0.004). Imaging quality is excellent with both tracers and they are potentially of value for brain imaging in various neuropsychiatric disorders. (orig.)

  9. Systematic Risk on Istanbul Stock Exchange: Traditional Beta Coefficient Versus Downside Beta Coefficient

    Directory of Open Access Journals (Sweden)

    Gülfen TUNA

    2013-03-01

    Full Text Available The aim of this study is to test the validity of Downside Capital Asset Pricing Model (D-CAPM on the ISE. At the same time, the explanatory power of CAPM's traditional beta and D-CAPM's downside beta on the changes in the average return values are examined comparatively. In this context, the monthly data for seventy three stocks that are continuously traded on the ISE for the period 1991-2009 is used. Regression analysis is applied in this study. The research results have shown that D-CAPM is valid on the ISE. In addition, it is obtained that the power of downside beta coefficient is higher than traditional beta coefficient on explaining the return changes. Therefore, it can be said that the downside beta is superior to traditional beta in the ISE for chosen period.

  10. Interventions to improve gross motor performance in children with neurodevelopmental disorders: a meta-analysis.

    Science.gov (United States)

    Lucas, Barbara R; Elliott, Elizabeth J; Coggan, Sarah; Pinto, Rafael Z; Jirikowic, Tracy; McCoy, Sarah Westcott; Latimer, Jane

    2016-11-29

    Gross motor skills are fundamental to childhood development. The effectiveness of current physical therapy options for children with mild to moderate gross motor disorders is unknown. The aim of this study was to systematically review the literature to investigate the effectiveness of conservative interventions to improve gross motor performance in children with a range of neurodevelopmental disorders. A systematic review with meta-analysis was conducted. MEDLINE, EMBASE, AMED, CINAHL, PsycINFO, PEDro, Cochrane Collaboration, Google Scholar databases and clinical trial registries were searched. Published randomised controlled trials including children 3 to ≤18 years with (i) Developmental Coordination Disorder (DCD) or Cerebral Palsy (CP) (Gross Motor Function Classification System Level 1) or Developmental Delay or Minimal Acquired Brain Injury or Prematurity (gross motor outcomes obtained using a standardised assessment tool. Meta-analysis was performed to determine the pooled effect of intervention on gross motor function. Methodological quality and strength of meta-analysis recommendations were evaluated using PEDro and the GRADE approach respectively. Of 2513 papers, 9 met inclusion criteria including children with CP (n = 2) or DCD (n = 7) receiving 11 different interventions. Only two of 9 trials showed an effect for treatment. Using the least conservative trial outcomes a large beneficial effect of intervention was shown (SMD:-0.8; 95% CI:-1.1 to -0.5) with "very low quality" GRADE ratings. Using the most conservative trial outcomes there is no treatment effect (SMD:-0.1; 95% CI:-0.3 to 0.2) with "low quality" GRADE ratings. Study limitations included the small number and poor quality of the available trials. Although we found that some interventions with a task-orientated framework can improve gross motor outcomes in children with DCD or CP, these findings are limited by the very low quality of the available evidence. High quality intervention

  11. Spatial distribution and risk assessment of radioactivity and heavy metal levels of sediment, surface water and fish samples from Lake Van, Turkey

    International Nuclear Information System (INIS)

    Sema Erenturk; Zeyneb Camtakan

    2014-01-01

    In this study, radioactivity levels of 228 lake water samples, 63 upper and depth sediment samples and 12 fish samples from Lake Van were investigated from 2005 to 2008 and the distribution patterns of the radionuclides were presented. Analysis included gross alpha-beta and total radium isotopes activities and uranium concentrations of the water, and gross alpha and gross beta activities and relevant 238 U, 232 Th and 40 K activity of the sediment and fish samples of the lake. Mean gross alpha, gross beta and radium isotopes activities of lake water were found 0.74 ± 0.46, 0.02 ± 0.01 and 0.06 ± 0.04 Bq/L, respectively. Mean gross alpha and beta activities in upper and depth sediments were found to be 41 ± 6 and 1,514 ± 74 Bq/kg; 77 ± 5 and 394 ± 24 Bq/kg at a 95 % confidence level, respectively. Mean activities of 238 U, 232 Th and 40 K activity concentrations in upper and depth sediments were determined to be 225 ± 22, 70 ± 7 and 486 ± 39 Bq/kg; 174 ± 4, 63 ± 3 and 263 ± 25 Bq/kg, respectively. The mean gross alpha and beta, 238 U, 232 Th and 40 K activities in fish samples were established as 47 ± 18, 470 ± 12, 0.57 ± 0.220, 0.022 ± 0.006, 319 ± 11 Bq/kg, respectively. The transfer factor from lake water to fish tissues, annual intake by humans consuming fish, and annual committed effective doses were estimated and evaluated. (author)

  12. Integrins beta 5, beta 3 and alpha v are apically distributed in endometrial epithelium.

    Science.gov (United States)

    Aplin, J D; Spanswick, C; Behzad, F; Kimber, S J; Vićovac, L

    1996-07-01

    Several adhesion molecules have been shown to occur at the surface of endometrial cells. One of these is the integrin alpha v subunit which associates with various beta chains including beta 5. We demonstrate the presence of integrin beta 5 polypeptide in human endometrial epithelial cells throughout the menstrual cycle using immunocytochemistry with monospecific antibodies, and at the mRNA level by thermal amplification from endometrial cDNA. Integrin beta 5 is also found in a population of bone marrow-derived cells. A notable feature of the distribution of the beta 5 subunit in the glandular and luminal epithelium is its apical localization, which may suggest an involvement in implantation. However, no evidence was found for regulated expression of epithelial beta 5. In mouse, the beta 5 subunit is found at both the apical and basal surface of epithelial cells and expression is essentially oestrous cycle-independent. Comparisons are made in both species with the distribution of the alpha v and beta 3 subunits which also localize to the apical epithelium.

  13. The effect of volume and quenching on estimation of counting efficiencies in liquid scintillation counting

    International Nuclear Information System (INIS)

    Knoche, H.W.; Parkhurst, A.M.; Tam, S.W.

    1979-01-01

    The effect of volume on the liquid scintillation counting performance of 14 C-samples has been investigated. A decrease in counting efficiency was observed for samples with volumes below about 6 ml and those above about 18 ml when unquenched samples were assayed. Two quench-correction methods, sample channels ratio and external standard channels ratio, and three different liquid scintillation counters, were used in an investigation to determine the magnitude of the error in predicting counting efficiencies when small volume samples (2 ml) with different levels of quenching were assayed. The 2 ml samples exhibited slightly greater standard deviations of the difference between predicted and determined counting efficiencies than did 15 ml samples. Nevertheless, the magnitude of the errors indicate that if the sample channels ratio method of quench correction is employed, 2 ml samples may be counted in conventional counting vials with little loss in counting precision. (author)

  14. Results of the radiological environmental monitoring network in Cantabria, Spain

    International Nuclear Information System (INIS)

    Soto, J.; Rodenas, C.; Gomez, J.; Quindos, L.S.; Fernandez, P.L.

    1997-01-01

    The Medical Physics Department in the University of Cantabria, Spain as member belonging to the radiological environmental Monitoring Network has been carried out a series of measures about radioactive elements in air, rain water and soil. This report shows the methodology used and the results obtained in the measurement of the gross-alpha and gross beta activities. 90S r and gamma spectrometry in atmospheric aerosols; the activity of 131I in air; the gross-beta activity 90 Sr and gamma spectrometry in rain water and dry deposition: and the activity of 90S r gamma spectrometer in soils. The average values of the gross-alpha and gross beta activities in air has been 4 x 10 -5 and 32 x10 -5B q/m 3, respectively. The concentration of 131I has been inferior to the limit of detection in the whole of measurements. Finally, has been found small concentrations of 90S r and the 137C s in soils samples

  15. Regulation of glycogen synthase kinase-3{beta} (GSK-3{beta}) after ionizing radiation; Regulation der Glykogen Synthase Kinase-3{beta} (GSK-3{beta}) nach ionisierender Strahlung

    Energy Technology Data Exchange (ETDEWEB)

    Boehme, K.A.

    2006-12-15

    Glycogen Synthase Kinase-3{beta} (GSK-3{beta}) phosphorylates the Mdm2 protein in the central domain. This phosphorylation is absolutely required for p53 degradation. Ionizing radiation inactivates GSK-3{beta} by phosphorylation at serine 9 and in consequence prevents Mdm2 mediated p53 degradation. During the work for my PhD I identified Akt/PKB as the kinase that phosphorylates GSK-3{beta} at serine 9 after ionizing radiation. Ionizing radiation leads to phosphorylation of Akt/PKB at threonine 308 and serine 473. The PI3 Kinase inhibitor LY294002 completely abolished Akt/PKB serine 473 phosphorylation and prevented the induction of GSK-3{beta} serine 9 phosphorylation after ionizing radiation. Interestingly, the most significant activation of Akt/PKB after ionizing radiation occurred in the nucleus while cytoplasmic Akt/PKB was only weakly activated after radiation. By using siRNA, I showed that Akt1/PKBa, but not Akt2/PKB{beta}, is required for phosphorylation of GSK- 3{beta} at serine 9 after ionizing radiation. Phosphorylation and activation of Akt/PKB after ionizing radiation depends on the DNA dependent protein kinase (DNA-PK), a member of the PI3 Kinase family, that is activated by free DNA ends. Both, in cells from SCID mice and after knockdown of the catalytic subunit of DNA-PK by siRNA in osteosarcoma cells, phosphorylation of Akt/PKB at serine 473 and of GSK-3{beta} at serine 9 was completely abolished. Consistent with the principle that phosphorylation of GSK-3 at serine 9 contributes to p53 stabilization after radiation, the accumulation of p53 in response to ionizing radiation was largely prevented by downregulation of DNA-PK. From these results I conclude, that ionizing radiation induces a signaling cascade that leads to Akt1/PKBa activation mediated by DNA-PK dependent phosphorylation of serine 473. After activation Akt1/PKBa phosphorylates and inhibits GSK-3{beta} in the nucleus. The resulting hypophosphorylated form of Mdm2 protein is no longer

  16. High beta experiments in CHS

    International Nuclear Information System (INIS)

    Okamura, S.; Matsuoka, K.; Nishimura, K.

    1994-09-01

    High beta experiments were performed in the low-aspect-ratio helical device CHS with the volume-averaged equilibrium beta up to 2.1 %. These values (highest for helical systems) are obtained for high density plasmas in low magnetic field heated with two tangential neutral beams. Confinement improvement given by means of turning off gas puffing helped significantly to make high betas. Magnetic fluctuations increased with increasing beta, but finally stopped to increase in the beta range > 1 %. The coherent modes appearing in the magnetic hill region showed strong dependence on the beta values. The dynamic poloidal field control was applied to suppress the outward plasma movement with the plasma pressure. Such an operation gave fixed boundary operations of high beta plasmas in helical systems. (author)

  17. TasselNet: counting maize tassels in the wild via local counts regression network.

    Science.gov (United States)

    Lu, Hao; Cao, Zhiguo; Xiao, Yang; Zhuang, Bohan; Shen, Chunhua

    2017-01-01

    Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting ( MTC ) dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large margins and achieves the overall best counting

  18. TasselNet: counting maize tassels in the wild via local counts regression network

    Directory of Open Access Journals (Sweden)

    Hao Lu

    2017-11-01

    Full Text Available Abstract Background Accurately counting maize tassels is important for monitoring the growth status of maize plants. This tedious task, however, is still mainly done by manual efforts. In the context of modern plant phenotyping, automating this task is required to meet the need of large-scale analysis of genotype and phenotype. In recent years, computer vision technologies have experienced a significant breakthrough due to the emergence of large-scale datasets and increased computational resources. Naturally image-based approaches have also received much attention in plant-related studies. Yet a fact is that most image-based systems for plant phenotyping are deployed under controlled laboratory environment. When transferring the application scenario to unconstrained in-field conditions, intrinsic and extrinsic variations in the wild pose great challenges for accurate counting of maize tassels, which goes beyond the ability of conventional image processing techniques. This calls for further robust computer vision approaches to address in-field variations. Results This paper studies the in-field counting problem of maize tassels. To our knowledge, this is the first time that a plant-related counting problem is considered using computer vision technologies under unconstrained field-based environment. With 361 field images collected in four experimental fields across China between 2010 and 2015 and corresponding manually-labelled dotted annotations, a novel Maize Tassels Counting (MTC dataset is created and will be released with this paper. To alleviate the in-field challenges, a deep convolutional neural network-based approach termed TasselNet is proposed. TasselNet can achieve good adaptability to in-field variations via modelling the local visual characteristics of field images and regressing the local counts of maize tassels. Extensive results on the MTC dataset demonstrate that TasselNet outperforms other state-of-the-art approaches by large

  19. Determination of natural radioactivity in irrigation water of drilled wells in northwestern Saudi Arabia.

    Science.gov (United States)

    Alkhomashi, N; Al-Hamarneh, Ibrahim F; Almasoud, Fahad I

    2016-02-01

    The levels of natural radiation in bedrock groundwater extracted from drilled wells in selected farms in the northwestern part of Saudi Arabia were addressed. The investigated waters form a source of irrigation for vegetables, agricultural crops, wheat, and alfalfa to feed livestock consumed by the general public. Information about water radioactivity in this area is not available yet. Therefore, this study strives to contribute to the quality assessment of the groundwater of these wells that are drilled into the non-renewable Saq sandstone aquifer. Hence, gross alpha and beta activities as well as the concentrations of (224)Ra, (226)Ra, (228)Ra, (234)U, (238)U, and U(total) were measured, compared to national and international limits and contrasted with data quoted from the literature. Correlations between the activities of the analyzed radionuclides were discussed. The concentrations of gross alpha and beta activities as well as (228)Ra were identified by liquid scintillation counting whereas alpha spectrometry was used to determine (224)Ra, (226)Ra, (234)U and (238)U after separation from the matrix by extraction chromatography. The mean activity concentrations of gross α and β were 3.15 ± 0.26 Bq L(-1) and 5.39 ± 0.44 Bq L(-1), respectively. Radium isotopes ((228)Ra and (226)Ra) showed mean concentrations of 3.16 ± 0.17 Bq L(-1) and 1.12 ± 0.07 Bq L(-1), respectively, whereas lower levels of uranium isotopes ((234)U and (238)U) were obtained. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Conformation, molecular packing and field effect mobility of regioregular beta,beta'-dihexylsexithiophiophene

    DEFF Research Database (Denmark)

    Kiriy, N.; Kiriy, A.; Bocharova, V.

    2004-01-01

    by the pulse-radiolysis time-resolved microwave conductivity (PR-TRMC) technique was found to be Sigmamu(min) = 3.9 x 10(-3) cm(2) V-1 s(-1), which is comparable with the PR-TRMC mobility found for alpha,omega-DH6T. The field-effect mobility (FEM) of beta,beta'-DH6T was found to be on the order of 10(-5) cm(2......) V-1 s(-1), which is considerably less than the FEM of alpha,omega-DH6T. To understand the reason for such poor macroscopic electrical properties, the conformation and the molecular packing of beta,beta'-DH6T were systematically studied by means of UV-vis spectroscopy, scanning electron microscopy...... less dense crystalline packing than alpha,omega-DH6T. In contrast to the almost upright orientation of alpha,omega-DH6T molecules against the substrate (tilt angle about 68), the long axis of beta,beta'-DH6T molecules and the surface plane form an angle of similar to20degrees. Thus, the crystalline...

  1. Relation between hand function and gross motor function in full term infants aged 4 to 8 months

    Directory of Open Access Journals (Sweden)

    Solange F. Nogueira

    2015-02-01

    Full Text Available Background: In children, reaching emerges around four months of age, which is followed by rapid changes in hand function and concomitant changes in gross motor function, including the acquisition of independent sitting. Although there is a close functional relationship between these domains, to date they have been investigated separately. Objective: To investigate the longitudinal profile of changes and the relationship between the development of hand function (i.e. reaching for and manipulating an object and gross motor function in 13 normally developing children born at term who were evaluated every 15 days from 4 to 8 months of age. Method: The number of reaches and the period (i.e. time of manipulation to an object were extracted from video synchronized with the Qualisys(r movement analysis system. Gross motor function was measured using the Alberta Infant Motor Scale. ANOVA for repeated measures was used to test the effect of age on the number of reaches, the time of manipulation and gross motor function. Hierarchical regression models were used to test the associations of reaching and manipulation with gross motor function. Results: Results revealed a significant increase in the number of reaches (p<0.001, the time of manipulation (p<0.001 and gross motor function (p<0.001 over time, as well as associations between reaching and gross motor function (R2=0.84; p<0.001 and manipulation and gross motor function (R2=0.13; p=0.02 from 4 to 6 months of age. Associations from 6 to 8 months of age were not significant. Conclusion: The relationship between hand function and gross motor function was not constant, and the age span from 4 to 6 months was a critical period of interdependency of hand function and gross motor function development.

  2. Gross α/β analysis of spiked qater for IAEA 2008 world-wide open proficiency test

    International Nuclear Information System (INIS)

    Zhang Yaoling; Zhao Feng; Wu Meigui; Du Jinzhou

    2010-01-01

    The gross α/β analysis of the IAEA 2008 world-wide open proficiency test on the determination of natural radionuclides in spiked water was conducted. The Sample 03, Sample 04 and Sample 05 were tested for the gross α/β radioactivity according to the requirement of IAEA. The feedback statistics showed that the values of gross α/β of all of the three samples fell in the acceptable range of IAEA. (authors)

  3. 26 CFR 1.804-3 - Gross investment income of a life insurance company.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Gross investment income of a life insurance company. 1.804-3 Section 1.804-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Investment Income § 1.804-3 Gross investment income of a life...

  4. 26 CFR 1.1332-1 - Inclusion in gross income of war loss recoveries.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 11 2010-04-01 2010-04-01 true Inclusion in gross income of war loss recoveries. 1.1332-1 Section 1.1332-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES War Loss Recoveries § 1.1332-1 Inclusion in gross income of...

  5. Gross Motor Development of Malaysian Hearing Impaired Male Pre- and Early School Children

    Science.gov (United States)

    Zawi, Khairi; Lian, Denise Koh Choon; Abdullah, Rozlina Tan

    2014-01-01

    Acquisition of gross motor skill is a natural developmental process for children. This aspect of human development increases with one's chronological age, irrespective of any developmental conditions. The purpose of this study was to assess the level of gross motor skill development among pre- and early school-aged children with motor disability.…

  6. Determination of 226 Ra and 228 Ra in mineral spring waters of the Aguas da Prata region

    International Nuclear Information System (INIS)

    Oliveira, J. de.

    1993-01-01

    Concentration levels of 226 Ra and 228 Ra have been analysed in most of the mineral spring waters available in the Aguas da Prata region. The 226 Ra and 228 Ra were determined by coprecipitation with barium sulphate. The 226 Ra was determined by gross alpha counting of the Ba(Ra)SO 4 precipitate. The determination of 228 Ra was done by measuring the gross beta activity of the same precipitate. Both measurements were carried out in a low background gas flow proportional counter. Dose calculations were performed in order to evaluate the relative importance of such radionuclides to the radiation exposure due to the ingestion of these waters. Based upon measured concentrations, committed effective doses up to 5.5 x 10 -1 mSv/y and 1.0 x 10 -2 mSv/y were observed for 226 Ra and 228 Ra, respectively. These results show that 226 Ra is the main contributor to radiation exposure. (author)

  7. Levered and unlevered Beta

    OpenAIRE

    Fernandez, Pablo

    2003-01-01

    We prove that in a world without leverage cost the relationship between the levered beta ( L) and the unlevered beta ( u) is the No-costs-of-leverage formula: L = u + ( u - d) D (1 - T) / E. We also analyze 6 alternative valuation theories proposed in the literature to estimate the relationship between the levered beta and the unlevered beta (Harris and Pringle (1985), Modigliani and Miller (1963), Damodaran (1994), Myers (1974), Miles and Ezzell (1980), and practitioners) and prove that all ...

  8. Isospectral discrete and quantum graphs with the same flip counts and nodal counts

    Science.gov (United States)

    Juul, Jonas S.; Joyner, Christopher H.

    2018-06-01

    The existence of non-isomorphic graphs which share the same Laplace spectrum (to be referred to as isospectral graphs) leads naturally to the following question: what additional information is required in order to resolve isospectral graphs? It was suggested by Band, Shapira and Smilansky that this might be achieved by either counting the number of nodal domains or the number of times the eigenfunctions change sign (the so-called flip count) (Band et al 2006 J. Phys. A: Math. Gen. 39 13999–4014 Band and Smilansky 2007 Eur. Phys. J. Spec. Top. 145 171–9). Recent examples of (discrete) isospectral graphs with the same flip count and nodal count have been constructed by Ammann by utilising Godsil–McKay switching (Ammann private communication). Here, we provide a simple alternative mechanism that produces systematic examples of both discrete and quantum isospectral graphs with the same flip and nodal counts.

  9. Boosted beta regression.

    Directory of Open Access Journals (Sweden)

    Matthias Schmid

    Full Text Available Regression analysis with a bounded outcome is a common problem in applied statistics. Typical examples include regression models for percentage outcomes and the analysis of ratings that are measured on a bounded scale. In this paper, we consider beta regression, which is a generalization of logit models to situations where the response is continuous on the interval (0,1. Consequently, beta regression is a convenient tool for analyzing percentage responses. The classical approach to fit a beta regression model is to use maximum likelihood estimation with subsequent AIC-based variable selection. As an alternative to this established - yet unstable - approach, we propose a new estimation technique called boosted beta regression. With boosted beta regression estimation and variable selection can be carried out simultaneously in a highly efficient way. Additionally, both the mean and the variance of a percentage response can be modeled using flexible nonlinear covariate effects. As a consequence, the new method accounts for common problems such as overdispersion and non-binomial variance structures.

  10. Regulation of beta cell replication

    DEFF Research Database (Denmark)

    Lee, Ying C; Nielsen, Jens Høiriis

    2008-01-01

    Beta cell mass, at any given time, is governed by cell differentiation, neogenesis, increased or decreased cell size (cell hypertrophy or atrophy), cell death (apoptosis), and beta cell proliferation. Nutrients, hormones and growth factors coupled with their signalling intermediates have been...... suggested to play a role in beta cell mass regulation. In addition, genetic mouse model studies have indicated that cyclins and cyclin-dependent kinases that determine cell cycle progression are involved in beta cell replication, and more recently, menin in association with cyclin-dependent kinase...... inhibitors has been demonstrated to be important in beta cell growth. In this review, we consider and highlight some aspects of cell cycle regulation in relation to beta cell replication. The role of cell cycle regulation in beta cell replication is mostly from studies in rodent models, but whether...

  11. Complement activation by the amyloid proteins A beta peptide and beta 2-microglobulin

    DEFF Research Database (Denmark)

    Nybo, Mads; Nielsen, E H; Svehag, S E

    1999-01-01

    component nor heparan sulfate did significantly alter the A beta-induced CA. The results indicate that not only fibrillar A beta but also oligomers of, in particular, beta 2M from patients with dialysis-associated amyloidosis are capable of inducing CA at supra-physiological concentrations....

  12. Gross changes in forest area shape the future carbon balance of tropical forests

    Science.gov (United States)

    Li, Wei; Ciais, Philippe; Yue, Chao; Gasser, Thomas; Peng, Shushi; Bastos, Ana

    2018-01-01

    Bookkeeping models are used to estimate land-use and land-cover change (LULCC) carbon fluxes (ELULCC). The uncertainty of bookkeeping models partly arises from data used to define response curves (usually from local data) and their representativeness for application to large regions. Here, we compare biomass recovery curves derived from a recent synthesis of secondary forest plots in Latin America by Poorter et al. (2016) with the curves used previously in bookkeeping models from Houghton (1999) and Hansis et al. (2015). We find that the two latter models overestimate the long-term (100 years) vegetation carbon density of secondary forest by about 25 %. We also use idealized LULCC scenarios combined with these three different response curves to demonstrate the importance of considering gross forest area changes instead of net forest area changes for estimating regional ELULCC. In the illustrative case of a net gain in forest area composed of a large gross loss and a large gross gain occurring during a single year, the initial gross loss has an important legacy effect on ELULCC so that the system can be a net source of CO2 to the atmosphere long after the initial forest area change. We show the existence of critical values of the ratio of gross area change over net area change (γAnetAgross), above which cumulative ELULCC is a net CO2 source rather than a sink for a given time horizon after the initial perturbation. These theoretical critical ratio values derived from simulations of a bookkeeping model are compared with observations from the 30 m resolution Landsat Thematic Mapper data of gross and net forest area change in the Amazon. This allows us to diagnose areas in which current forest gains with a large land turnover will still result in LULCC carbon emissions in 20, 50 and 100 years.

  13. Are Gross Motor Skills and Sports Participation Related in Children with Intellectual Disabilities?

    Science.gov (United States)

    Westendorp, Marieke; Houwen, Suzanne; Hartman, Esther; Visscher, Chris

    2011-01-01

    This study compared the specific gross motor skills of 156 children with intellectual disabilities (ID) (50 less than or equal to IQ greater than or equal to 79) with that of 255 typically developing children, aged 7-12 years. Additionally, the relationship between the specific gross motor skills and organized sports participation was examined in…

  14. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  15. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  16. Anomaly detection in real-time gross payment data

    NARCIS (Netherlands)

    Triepels, Ron; Daniels, Hennie; Heijmans, R.; Camp, Olivier; Filipe, Joaquim

    2017-01-01

    We discuss how an autoencoder can detect system-level anomalies in a real-time gross settlement system by reconstructing a set of liquidity vectors. A liquidity vector is an aggregated representation of the underlying payment network of a settlement system for a particular time interval.

  17. Potato production in Europe - a gross margin analysis

    DEFF Research Database (Denmark)

    Pedersen, Søren Marcus; Bizik, Jan; Costa, Luisa Dalla

    The purpose of this paper is to examine different cropping practices, cost structures and gross margins for producing conventional table potatoes in 6 different regions within the European Union: Czech Republic, Denmark, Italy, Poland, Portugal and Slovakia. Findings from this study show that pot...

  18. Improved limits on beta(-) and beta(-) decays of Ca-48

    Czech Academy of Sciences Publication Activity Database

    Bakalyarov, A.; Balysh, A.; Barabash, AS.; Beneš, P.; Briancon, C.; Brudanin, V. B.; Čermák, P.; Egorov, V.; Hubert, F.; Hubert, P.; Korolev, NA.; Kosjakov, VN.; Kovalík, Alojz; Lebedev, NA.; Novgorodov, A. F.; Rukhadze, NI.; Štekl, NI.; Timkin, VV.; Veleshko, IE.; Vylov, T.; Umatov, VI.

    2002-01-01

    Roč. 76, č. 9 (2002), s. 545-547 ISSN 0021-3640 Institutional research plan: CEZ:AV0Z1048901 Keywords : beta decay * double beta decay * Ca-48 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.483, year: 2002

  19. Improvements of mass formula and β-decay gross theory

    International Nuclear Information System (INIS)

    Tachibana, Takahiro

    1987-01-01

    The nuclear mass greatly decreases when the number of protons Z and neutrons N is simultaneously equal to a magic number (mutual support of magicities). The mass also tends to decrease due to deformation as both N and Z are away from the magic numbers (mutual support of deformations). These two effects are introduced to a nuclear mass formula containing a constant-type shell term to derive a new formula. The mass excess is expressed by a sum of three parts, i.e. gross part, even-odd part and shell part. The gross part, which represents the general nature, consists of two rest mass terms and a coulomb term. The even-odd part is of a typical form with a correction term. The shell part consists of a proton shell term, neutron shell term, third term expressing the two mutual support effects, and fourth term representing a decrease in coulomb energy due to deformation of the nucleus. The improvements made in the β-decay gross theory are associated with the single particle intensity function D 0 GT (E,ε). They are intended for: (1) reproducing the peak that accounts for about a half of the Gamow-Teller intensity, which has recently been found in (p,n) reactions at energies above the isobaric analogue state and (2) explaining the other half by an exponential-type D 0 GT (E,ε). (Nogami, K.)

  20. Comparison of gross anatomy test scores using traditional specimens vs. QuickTime Virtual Reality animated specimens

    Science.gov (United States)

    Maza, Paul Sadiri

    In recent years, technological advances such as computers have been employed in teaching gross anatomy at all levels of education, even in professional schools such as medical and veterinary medical colleges. Benefits of computer based instructional tools for gross anatomy include the convenience of not having to physically view or dissect a cadaver. Anatomy educators debate over the advantages versus the disadvantages of computer based resources for gross anatomy instruction. Many studies, case reports, and editorials argue for the increased use of computer based anatomy educational tools, while others discuss the necessity of dissection for various reasons important in learning anatomy, such as a three-dimensional physical view of the specimen, physical handling of tissues, interactions with fellow students during dissection, and differences between specific specimens. While many articles deal with gross anatomy education using computers, there seems to be a lack of studies investigating the use of computer based resources as an assessment tool for gross anatomy, specifically using the Apple application QuickTime Virtual Reality (QTVR). This study investigated the use of QTVR movie modules to assess if using computer based QTVR movie module assessments were equal in quality to actual physical specimen examinations. A gross anatomy course in the College of Veterinary Medicine at Cornell University was used as a source of anatomy students and gross anatomy examinations. Two groups were compared, one group taking gross anatomy examinations in a traditional manner, by viewing actual physical specimens and answering questions based on those specimens. The other group took the same examinations using the same specimens, but the specimens were viewed as simulated three-dimensional objects in a QTVR movie module. Sample group means for the assessments were compared. A survey was also administered asking students' perceptions of quality and user-friendliness of the QTVR