WorldWideScience

Sample records for gross beta counting

  1. Gross alpha and gross beta determination in surface and groundwater water by liquid scintillation counting (LSC)

    International Nuclear Information System (INIS)

    Faria, Ligia S.; Moreira, Rubens M.

    2013-01-01

    The present study has used 40 samples of groundwater and surface water collected at four different sites along the period of one year in Brumadinho and Nova Lima, two municipalities in the State of Minas Gerais, Brazil, as part of a more extensive study aiming at determination of the natural radioactivity in the water used for domestic use. These two sites are inside an Environmental Protection Area is located in a region of very intensive iron ore exploration. In addition of mineral resources, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium. Radioactivity levels were determined via liquid scintillation counting (LSC), a fast and high counting efficiency method that can be advantageously employed to determine gross alpha and gross beta activity in liquid samples. Previously to gross alpha and gross beta counting the samples were acidified with concentrated HNO 3 in the field. The technique involved a pre-concentration of the sample to obtain a low detection limit. Specific details of the employed methodology are commented. The results showed that concentrations of gross alpha natural activity and gross beta values ranged from less than the detection limit of the equipment (0.03 Bq.L -1 ) to 0.275 ± 0.05 Bq.L -1 for gross alpha. As regards gross beta, all samples were below the limit of detection. (author)

  2. A Method Validation for Determination of Gross Alpha and Gross Beta in Water Sample Using Low Background Gross Alpha/ Beta Counting System

    International Nuclear Information System (INIS)

    Zal Uyun Wan Mahmood; Norfaizal Mohamed; Nita Salina Abu Bakar

    2016-01-01

    Method validation (MV) for the measurement of gross alpha and gross beta activity in water (drinking, mineral and environmental) samples using Low Background Gross Alpha/ Beta Counting System was performed to characterize precision, accuracy and reliable results. The main objective of this assignment is to ensure that both the instrument and method always good performed and resulting accuracy and reliable results. Generally, almost the results of estimated RSD, z-score and U_s_c_o_r_e were reliable which are recorded as ≤30 %, less than 2 and less than 1.5, respectively. Minimum Detected Activity (MDA) was estimated based on the counting time of 100 minutes and present background counting value of gross alpha (0.01 - 0.35 cpm) and gross beta (0.50 - 2.18 cpm). Estimated Detection Limit (DL) was 0.1 Bq/ L for gross alpha and 0.2 Bq/ L for gross beta and expended uncertainty was relatively small of 9.77 % for gross alpha and 10.57 % for gross beta. Align with that, background counting for gross alpha and gross beta was ranged of 0.01 - 0.35 cpm and 0.50 - 2.18 cpm, respectively. While, sample volume was set at minimum of 500 mL and maximum of 2000 mL. These proven the accuracy and precision result that are generated from developed method/ technique is satisfactory and method is recommended to be used. Therefore, it can be concluded that the MV found no doubtful on the ability of the developed method. The test result showed the method is suitable for all types of water samples which are contained several radionuclides and elements as well as any impurities that interfere the measurement analysis of gross alpha and gross beta. (author)

  3. Gross alpha/beta analyses in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Wong, C.T.; Lawrence Livermore National Laboratory, CA; Soliman, V.M.; Perera, S.K.

    2005-01-01

    The standard procedure for analyzing gross alpha and gross beta in water is evaporation of the sample and radioactivity determination of the resultant solids by proportional counting. This technique lacks precision, and lacks sensitivity for samples with high total dissolved solids. Additionally, the analytical results are dependent on the choice of radionuclide calibration standard and the sample matrix. Direct analysis by liquid scintillation counting has the advantages of high counting efficiencies and minimal sample preparation time. However, due to the small sample aliquants used for analysis, long count times are necessary to reach required detection limits. The procedure proposed consists of evaporating a sample aliquant to dryness, dissolving the resultant solids in a small volume of dilute acid, followed by liquid scintillation counting to determine radioactivity. This procedure can handle sample aliquants containing up to 500 mg of dissolved solids. Various acids, scintillation cocktail mixtures, instrument discriminator settings, and regions of interest (ROI) were evaluated to determine optimum counting conditions. Precision is improved and matrix effects are reduced as compared to proportional counting. Tests indicate that this is a viable alternative to proportional counting for gross alpha and gross beta analyses of water samples. (author)

  4. Rapid determination of gross alpha and beta activity in seafood utilizing microwave digestion and liquid scintillation counting

    International Nuclear Information System (INIS)

    Daniel Sas; Jiri Janda; Alena Tokarova

    2015-01-01

    This paper describes a method for rapid determination of gross alpha and beta activity in seafood using liquid scintillation counting and microwave digestion for fast sample decomposition. The general group of seafood was divided into two groups based on its structure, whether it has shell or not. The selected group of radionuclides was chosen with respect to military significance, radiotoxicity, and possibility of potential misuse. 90 Sr and 239 Pu were selected as model radionuclides. (author)

  5. The influence of the calibration standard and the chemical composition of the water samples residue in the counting efficiency of proportional detectors for gross alpha and beta counting. Application on the radiologic control of the IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Santos, Cecilia Martins

    2003-01-01

    In this work the efficiency calibration curves of thin-window and low background gas-flow proportional counters were determined for calibration standards with different energies and different absorber thicknesses. For the gross alpha counting we have used 241 Am and natural uranium standards and for the gross beta counting we have used 90 Sr/ 90 Y and 137 Cs standards in residue thicknesses ranging from 0 to approximately 18 mg/cm 2 . These sample thicknesses were increased with a previously determined salted solution prepared simulating the chemical composition of the underground water of IPEN The counting efficiency for alpha emitters ranged from 0,273 +- 0,038 for a weightless residue to only 0,015 +- 0,002 in a planchet containing 15 mg/cm 2 of residue for 241 Am standard. For natural uranium standard the efficiency ranged from 0,322 +- 0,030 for a weightless residue to 0,023 +- 0,003 in a planchet containing 14,5 mg/cm 2 of residue. The counting efficiency for beta emitters ranged from 0,430 +- 0,036 for a weightless residue to 0,247 +- 0,020 in a planchet containing 17 mg/cm 2 of residue for 137 Cs standard. For 90 Sr/ 90 Y standard the efficiency ranged from 0,489 +- 0,041 for a weightless residue to 0,323 +- 0,026 in a planchet containing 18 mg/cm 2 of residue. Results make evident the counting efficiency variation with the alpha or beta emitters energies and the thickness of the water samples residue. So, the calibration standard, the thickness and the chemical composition of the residue must always be considered in the gross alpha and beta radioactivity determination in water samples. (author)

  6. Determination of gross gamma and gross beta activities in liquid effluent samples. Phase I

    International Nuclear Information System (INIS)

    Curtis, K.E.; Sood, S.P.

    1985-08-01

    Several inadequacies in the presently used procedures for gross gamma and gross beta measurements in aqueous wastes have been identified. Both the presence of suspended particulate activity and the use of cesium-137 as a calibration standard can cause gross gamma measurements to overestimate the actual activity in the sample. At the same time, sample preparation for the determination of gross beta activities causes large losses of radioiodine before the measurement step and the presence of solid material can cause a serious decrease in the beta counting efficiency. A combination of these errors could result in large discrepancies between the results obtained by the two measurement methods. Improved procedures are required to overcome these problems

  7. Monitoring of gross alpha, gross beta and tritium activities in portuguese drinking waters

    International Nuclear Information System (INIS)

    Lopes, I.; Madruga, M.J.; Ferrador, G.O.; Sequeira, M.M.; Oliveira, E.J.; Gomes, A.R.; Rodrigues, F.D.; Carvalho, F.P.

    2006-01-01

    The gross beta and tritium activities in the forty Portuguese drinking waters analyzed using the ISO standard methods (Portuguese Guidelines) are below the guidance levels proposed in the Portuguese Drinking Water Quality Guidelines. In what concerns the gross alpha activity only 18% exceeded the recommended level. In general, it can be concluded that the ingestion of these drinking waters does not create a radiological hazard to the human consumption, however, more detailed analyses will be necessary mainly the determinations of the individual alpha emitters radionuclide concentrations. The minimum gross alpha and gross beta detectable activities by L.S.C. methodology are higher than for the proportional counting technique (ISO method). Higher concentration factors will be needed to reach lower required detection limits. (authors)

  8. Innovative procedure for the determination of gross-alpha/gross-beta activities in drinking water

    International Nuclear Information System (INIS)

    Wisser, S.; Frenzel, E.; Dittmer, M.

    2006-01-01

    An alternative sample preparation method for the determination of gross-alpha/beta activity concentrations in drinking water is introduced in this paper. After the freeze-drying of tap water samples, determination by liquid scintillation counting can be applied utilizing alpha/beta separation. It has been shown that there is no adsorption or loss of solid radionuclides during the freeze-drying procedure. However, the samples have to be measured quickly after the preparation since the ingrowth of daughter isotopes negatively effects the measurement. The limits of detection for gross-alpha and gross-beta activity are in the range 25-210 mBq/l, respectively, for a measurement time of only 8-9 h

  9. Gross alpha and beta activities in Tunisian mineral water

    International Nuclear Information System (INIS)

    Hamrouni Benbelgacem, Samar

    2011-01-01

    The quality of natural mineral water is a universal health problem seeing its vital importance. This problem is related to the presence of the radionuclides since this water is coming from underground, during their circulation it dissolves and conveys the radionuclides which are present in the earth's crust. This problem which leads to the contamination of the mineral water urged the World Health Organization to set standards and to recommend the respect of the median values of the activities alpha and beta within the framework of the man protection against this internal exhibition. Concerning the radiological quality of Tunisian mineral water studied in this project, we showed, by using the gross alpha and beta activities counting, that this water is specific to human consumption since their gross alpha and beta activities do not forward any risk on health.

  10. Measurement of Gross Alpha and Gross Beta Radioactivity of River Yobe, North Eastern Nigeria

    International Nuclear Information System (INIS)

    Abba, H. T.; Sadiq, U.; Adeyemo, D. J.

    2013-01-01

    Measurement of the gross alpha and gross beta radioactivity of River Yobe has been carried out. Fifteen samples of the river water were collected from the farming, fishing, domestic/livestock and control areas along the river and were analyzed using desktop alpha/beta (MPC 2000- DP) counting system. The count results show the average alpha activities in farming, fishing, domestic/livestock and control areas are 0.207±0.082, 0.257±0.13, 0.437±0.315 and 0.237±0.10 Bq L -1 , respectively. The average beta activities in the four areas are 0.813±0.122, 0.308±0.0145, 0.563±0.230 and 0.225±0.0096 Bq L -1 , respectively. The overall results show that the alpha and beta activities in the four areas are far below the practical screening level of radioactivity in drinking water of 0.5 Bq L -1 for alpha and 1 Bq L -1 for beta recommended by CEC-FAO and WHO and therefore may not pose any serious detrimental health side-effects to the public users of the river.

  11. Influence of crosstalk phenomenon on the measurement of gross alpha and gross beta radioactivity in drinking water

    International Nuclear Information System (INIS)

    Gerilemandahu; Haribala; Xu Xiao; Shen Na; Sai Wenga; Bai Guilin; Wang Chengguo

    2014-01-01

    Objective: To study the influence of crosstalk phenomenon on the measurement of gross radioactivity in drinking water. Methods: The gross activity in different standard materials with different thickness and area was measured using national standard method. Results: There was no obvious change in crosstalk factor with the increase of "2"4"1Am powder amount in the measurement, whereas the larger amount of uranium used might lead to larger crosstalk factor. The different measurement channels resulted in different crosstalk factors. The influence of beta radioactivity on alpha radioactivity measurement was significant. On the contrary, the alpha-to-beta crosstalk factor was negligible. The area of sample plate imposed no significant influence on crosstalk factor. Conclusions: The gross beta activity can be corrected to decrease the influence of alpha radioactivity using powder standard samples, when simultaneous alpha and beta counting mode is applied in measurement grass radioactivity in drinking water. (authors)

  12. Measurement of gross alpha and beta in air filter samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Sudheendran, V.; Baburajan, A.; Gaikwad, R.H.; Ravi, P.M.; Tripathi, R.M.

    2015-01-01

    The determination of gross alpha and gross beta in particulate air filter samples was carried out by alpha, beta discrimination method using Liquid Scintillation Analyzer by setting the PSA value at 55 for 5 ml 0.1 HCl plus 15 ml of Ultima Gold AB cocktail by using 241 Am and 90 Sr/ 90 Y sources. The standardized method was compared with the gross alpha and gross beta activity determined by conventional method of direct counting with end window G.M. counter and ZnS (Ag). The minimum detectable activity of LSA method was found to be 9.3 mBq and 17.7 mBq for gross alpha and gross beta respectively for 6000 sec compared to the conventional method of 9.8 mBq and 189 mBq respectively at the same counting time. The result of analysis by both method indicate that the alpha, beta discrimination set up of LSA method is highly effective in the determination of low level alpha, beta activity in air filter samples. (author)

  13. Estimation of low level gross alpha activities in the radioactive effluent using liquid scintillation counting technique

    International Nuclear Information System (INIS)

    Bhade, Sonali P.D.; Johnson, Bella E.; Singh, Sanjay; Babu, D.A.R.

    2012-01-01

    A technique has been developed for simultaneous measurement of gross alpha and gross beta activity concentration in low level liquid effluent samples in presence of higher activity concentrations of tritium. For this purpose, alpha beta discriminating Pulse Shape Analysis Liquid Scintillation Counting (LSC) technique was used. Main advantages of this technique are easy sample preparation, rapid measurement and higher sensitivity. The calibration methodology for Quantulus1220 LSC based on PSA technique using 241 Am and 90 Sr/ 90 Y as alpha and beta standards respectively was described in detail. LSC technique was validated by measuring alpha and beta activity concentrations in test samples with known amount of 241 Am and 90 Sr/ 90 Y activities spiked in distilled water. The results obtained by LSC technique were compared with conventional planchet counting methods such as ZnS(Ag) and end window GM detectors. The gross alpha and gross beta activity concentrations in spiked samples, obtained by LSC technique were found to be within ±5% of the reference values. (author)

  14. A survey of gross alpha and gross beta activity in soil samples in Kinta District, Perak, Malaysia

    International Nuclear Information System (INIS)

    Lee, Siak Kuan; Wagiran, Husin; Ramli, Ahmad Termizi

    2014-01-01

    The objective of this study was to determine the gross alpha and gross beta activity concentrations from the different soil types found in the Kinta District, Perak, Malaysia. A total of 128 soil samples were collected and their dose rates were measured 1 m above the ground. Gross alpha and gross beta activity measurements were carried out using gas flow proportional counter, Tennelec Series 5 LB5500 Automatic Low Background Counting System. The alpha activity concentration ranged from 15 to 9634 Bq kg -1 with a mean value of 1558±121 Bq kg -1 . The beta activity concentration ranged from 142 to 6173 Bq kg -1 with a mean value of 1112±32 Bq kg -1 . High alpha and beta activity concentrations are from the same soil type. The results of the analysis show a strong correlation between the gross alpha activity concentration and dose rate (R = 0.92). The data obtained can be used as a database for each soil type. (authors)

  15. Requirement of radiochemical recovery determination for gross alpha and gross beta estimation in drinking water

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Rao, D.D.; Hegde, A.G.

    2010-01-01

    Presence of radionuclides in drinking water which emits Alpha and Beta particles are the potential sources of internal exposure in drinking water. Gross alpha and gross beta determination in drinking water and packaged drinking water (PDW) as per BIS (Bureau of Indian standards) standards is discussed here. The methods have been tested to account for losses in the radiochemical procedures using radionuclides such as 137 Cs, 90 Sr, 226 Ra, 239 Pu, 243 Am, 232 U. The methods have also been validated in an IAEA proficiency test conducted during 2009. Monitoring of gross alpha and gross beta activity observed in drinking water/packaged drinking water from various states of India were within the limits set by BIS. Average radiochemical recoveries of 84% and 63% were obtained for gross α and gross β respectively. (author)

  16. Measurement of gross alpha, gross beta, radon and radium activity concentrations in aqueous samples using liquid scintillation technique

    International Nuclear Information System (INIS)

    Zaini Hamzah; Ahmad Saat; Masitah Alias; Siti Afiqah Abdul Rahman; Mohamed Kasim; Abdul Kadir Ishak

    2011-01-01

    Recently, Malaysia has taken a positive step toward providing a better water quality by introducing more water quality parameters into its Water Quality Standard. With regard to the natural radionuclides that may present in the water, 3 parameters were introduced that is gross alpha, gross beta and radium which need to be measured and cannot exceed 0.1, 1.0 and 1.0 Bq/ L respectively. This study was conducted to develop a more practical method in measuring these parameters in aqueous environmental samples. Besides having a lot of former tin mining areas, some part of Malaysia is located on the granitic rock which also contributes to a certain extent the amount of natural radionuclides such as uranium and thorium. For all we know these two radionuclides are the origin of other radionuclides being produced from their decay series. The State of Kelantan was chosen as the study area, where the water samples were collected from various part of the Kelantan River. 25 liters of samples were collected, acidify to pH 2 and filtered before the analysis. Measurement of these parameters was done using liquid scintillation counter (LSC). The LSC was set up to the optimum discriminator level and counting was done using alpha-beta mode. The results show that gross alpha and beta can be measured using scintillation cocktail and radium and radon using extraction method. The results for gross alpha, gross beta, 222 Ra and 226 Ra are 0.39-6.42, 0.66-16.18, 0.40-4.65 and 0.05-0.56 Bq/ L. MDA for gross alpha, gross beta and radium is 0.03, 0.08 and 0.00035 Bq/ L respectively. (Author)

  17. Measurement of gross alpha and gross beta activity concentrations in human tooth

    International Nuclear Information System (INIS)

    Soeguet, Omer; Aydin, Mehmet Fatih; Kuecuekoender, Erdal; Zorer, Ozlem Selcuk; Dogru, Mahmut

    2010-01-01

    The gross alpha and gross beta activity concentrations were measured in human tooth taken from 3 to 6 age-groups to 40 and over ones. Accumulated teeth samples are investigated in two groups as under and above 18 years. The gross alpha and beta radioactivity of human tooth samples was measured by using a gas-flow proportional counter (PIC-MPC 9604-α/β counter). In tooth samples, for female age-groups, the obtained results show that the mean gross alpha and gross beta activity concentrations varied between 0.534-0.203 and 0.010-0.453 Bq g -1 and the same concentrations for male age-groups varied between 0.009-1.168 and 0.071-0.204 Bq g -1 , respectively.

  18. Determination of gross alpha and gross beta in soil around repository facility at Bukit Kledang, Perak, Malaysia

    Science.gov (United States)

    Adziz, Mohd Izwan Abdul; Siong, Khoo Kok

    2018-04-01

    Recently, the Long Term Storage Facility (LTSF) in Bukit Kledang, Perak, Malaysia, has been upgraded to repository facility upon the completion of decontamination and decommissioning (D&D) process. Thorium waste and contaminated material that may contain some minor amounts of thorium hydroxide were disposed in this facility. This study is conducted to determine the concentrations of gross alpha and gross beta radioactivities in soil samples collected around the repository facility. A total of 12 soil samples were collected consisting 10 samples from around the facility and 2 samples from selected residential area near the facility. In addition, the respective dose rates were measured 5 cm and 1 m above the ground by using survey meter with Geiger Muller (GM) detector and Sodium Iodide (NaI) detector. Soil samples were collected using hand auger and then were taken back to the laboratory for further analysis. Samples were cleaned, dried, pulverized and sieved prior to analysis. Gross alpha and gross beta activity measurements were carried out using gas flow proportional counter, Canberra Series 5 XLB - Automatic Low Background Alpha and Beta Counting System. The obtained results show that, the gross alpha and gross beta activity concentration ranged from 1.55 to 5.34 Bq/g with a mean value of 3.47 ± 0.09 Bq/g and 1.64 to 5.78 Bq/g with a mean value of 3.49 ± 0.09 Bq/g, respectively. These results can be used as an additional data to represent terrestrial radioactivity baseline data for Malaysia environment. This estimation will also serve as baseline for detection of any future related activities of contamination especially around the repository facility area.

  19. Gross beta activity of the Danube river samples in 2006

    International Nuclear Information System (INIS)

    Tanaskovic, I.; Pantelic, G.; Eremic-Savkovic, M.; Vuletic, V.; Javorina, Lj.; Tanaskovic, I.)

    2007-01-01

    Our paper presents the results of radioactivity control of the Danube samples on Serbian (Bezdan left coast) in 2006. The measurements were carried out by low-phone proportional gas alpha beta counter PIC-WPC-9550. Efficiency for activity was 47%. The results of measurements of gross beta activity (water, sediment, algae and fish) reveal that the values are at the same level as they were before the Paks Nuclear power plant started running. Our results of measurements correlate well with the results of Hungarian part. (author) [sr

  20. Preparation and validation of gross alpha/beta samples used in EML's quality assessment program

    International Nuclear Information System (INIS)

    Scarpitta, S.C.

    1997-10-01

    A set of water and filter samples have been incorporated into the existing Environmental Measurements Laboratory's (EML) Quality Assessment Program (QAP) for gross alpha/beta determinations by participating DOE laboratories. The participating laboratories are evaluated by comparing their results with the EML value. The preferred EML method for measuring water and filter samples, described in this report, uses gas flow proportional counters with 2 in. detectors. Procedures for sample preparation, quality control and instrument calibration are presented. Liquid scintillation (LS) counting is an alternative technique that is suitable for quantifying both the alpha ( 241 Am, 230 Th and 238 Pu) and beta ( 90 Sr/ 90 Y) activity concentrations in the solutions used to prepare the QAP water and air filter samples. Three LS counting techniques (Cerenkov, dual dpm and full spectrum analysis) are compared. These techniques may be used to validate the activity concentrations of each component in the alpha/beta solution before the QAP samples are actually prepared

  1. Design of New Complex Detector Used for Gross Beta Measuring

    International Nuclear Information System (INIS)

    Zhang Junmin

    2010-01-01

    The level of gross β for radioactive aerosol in the containment of nuclear plants can indicate how serious the radioactive pollution is in the shell, and it can provide evidence which shows whether there is the phenomenon of leak in the boundaries of confined aquifer of the primary coolant circuit equipment.In the process of measuring, the counting of gross β is influenced by γ. In order to avoid the influence of γ, a new method was introduced and a new detector was designed using plastic scintillator as the major detecting component and BGO as the sub-component. Based on distinctive difference of light attenuation time, signal induced in them can be discriminated. γ background in plastic scintillator was subtracted according to the counting of γ in BGO. The functions of absolute detection efficiency were obtained. The simulation for Monte-Carlo method shows that the influence of γ background is decreased about one order of magnitude. (authors)

  2. Characterization Of The Alpha/Beta Counting System Type MPC 9400 And Its Utilization

    International Nuclear Information System (INIS)

    Makhsum; Sutarman; Fikri, Hanif; Handoko, Djati

    2000-01-01

    Have been carried out the experiment to determine the operation voltage, instrument stability, counting efficiency, figure of merit, and minimum detectable activity. This instrument used to count gross alpha and gross beta. This instrument belongs good stability at the confidence level of 95 % and the background count that was 0,144 cpm for alpha and 22,65 cpm for beta. The counting efficiency was 27,41 % (electrodeposition of Am-241), 6,57 % (deposition of Am-241), 51,82 % (deposition of Sr-90). The limit of detectable activity was 1,04 x 10 exp.-2 Bq (electrodeposition of Am-241), 4,35 x 10 exp.-2 Bq (% deposition of Sr 90)

  3. Beta-decay rate and beta-delayed neutron emission probability of improved gross theory

    Science.gov (United States)

    Koura, Hiroyuki

    2014-09-01

    A theoretical study has been carried out on beta-decay rate and beta-delayed neutron emission probability. The gross theory of the beta decay is based on an idea of the sum rule of the beta-decay strength function, and has succeeded in describing beta-decay half-lives of nuclei overall nuclear mass region. The gross theory includes not only the allowed transition as the Fermi and the Gamow-Teller, but also the first-forbidden transition. In this work, some improvements are introduced as the nuclear shell correction on nuclear level densities and the nuclear deformation for nuclear strength functions, those effects were not included in the original gross theory. The shell energy and the nuclear deformation for unmeasured nuclei are adopted from the KTUY nuclear mass formula, which is based on the spherical-basis method. Considering the properties of the integrated Fermi function, we can roughly categorized energy region of excited-state of a daughter nucleus into three regions: a highly-excited energy region, which fully affect a delayed neutron probability, a middle energy region, which is estimated to contribute the decay heat, and a region neighboring the ground-state, which determines the beta-decay rate. Some results will be given in the presentation. A theoretical study has been carried out on beta-decay rate and beta-delayed neutron emission probability. The gross theory of the beta decay is based on an idea of the sum rule of the beta-decay strength function, and has succeeded in describing beta-decay half-lives of nuclei overall nuclear mass region. The gross theory includes not only the allowed transition as the Fermi and the Gamow-Teller, but also the first-forbidden transition. In this work, some improvements are introduced as the nuclear shell correction on nuclear level densities and the nuclear deformation for nuclear strength functions, those effects were not included in the original gross theory. The shell energy and the nuclear deformation for

  4. Measurement of gross beta radioactivity in high-level liquid waste

    International Nuclear Information System (INIS)

    Lu Feng; Lin Cansheng; Zhang Xianzi; Chen Guoan; Zhang Chonghai

    1992-01-01

    Using beta plastic scintillation counter of low level background, gross beta radioactivity of twelve samples for high-level liquid waste is determined directly. Beta efficiency curves of plastic scintillation counter for four mass thickness are calibrated in advance. Determining gross beta radioactivity, gross efficiency of the scintillation counter for various energy beta ray is calculated via weighted mean method with the ratio of radioactivity for each nuclide. The ratio of radioactivity for nuclides which have gamma disintegration is determined in terms of the radioactivity measured by gamma spectrometer. The ratio of the radioactivity for 90 Sr which has purity beta disintegration is calculated in terms of half life time approximation. The ratio of the radioactivity for 147 Pm which also has purity disintegration is calculated by means of apparent cooling-time approximation. The uncertainty of results for the present work is about +-15%

  5. Gross beta determination in drinking water using scintillating fiber array detector.

    Science.gov (United States)

    Lv, Wen-Hui; Yi, Hong-Chang; Liu, Tong-Qing; Zeng, Zhi; Li, Jun-Li; Zhang, Hui; Ma, Hao

    2018-04-04

    A scintillating fiber array detector for measuring gross beta counting is developed to monitor the real-time radioactivity in drinking water. The detector, placed in a stainless-steel tank, consists of 1096 scintillating fibers, both sides of which are connected to a photomultiplier tube. The detector parameters, including working voltage, background counting rate and stability, are tested, and the detection efficiency is calibrated using standard potassium chloride solution. Water samples are measured with the detector and the results are compared with those by evaporation method. The results show consistency with those by evaporation method. The background counting rate of the detector is 38.131 ± 0.005 cps, and the detection efficiency for β particles is 0.37 ± 0.01 cps/(Bq/l). The MDAC of this system can be less than 1.0 Bq/l for β particles in 120 min without pre-concentration. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Design of a Quality Control Program for the Measurement of Gross Alpha and Gross Beta Activities (LMPR-CIEMAT)

    International Nuclear Information System (INIS)

    Alvarez, A.; Yague, L.; Gasco, C.; Navarro, N.; Higueras, E.; Noguerales, C.

    2010-01-01

    In accordance with international standards, general requirements for testing laboratories have to include a quality system for planning, implementing, and assessing the work performed by the organization and for carrying out required quality assurance and quality control. The purpose of internal laboratory quality control is to monitor performance, identify problems, and initiate corrective actions. This report describes the internal quality control to monitor the gross alpha and beta activities determination. Identification of specific performance indicators, the principles that govern their use and statistical means of evaluation are explained. Finally, calculation of alpha and beta specific activities, uncertainties and detection limits are performed. (Author) 10 refs.

  7. Uranium, thorium, gross alpha and gross beta assessment in fountain waters in towns of the Iron Quadrangle, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Claudia A.; Palmieri, Helena E.L.; Menezes, Maria Angela de B.C.; Chaves, Renata D.A.; Dalmazio, Ilza, E-mail: cferreiraquimica@yahoo.com.br, E-mail: help@cdtn.br, E-mail: menezes@cdtn.br, E-mail: rda@cdtn.br, E-mail: id@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    The Iron Quadrangle region is known worldwide for its diversity, both ores and rock types, which record a long and important period of Earth's history. For thousands of years erosive processes have exposed ancient rocks, Archean and Proterozoic, in this region. The concentration of uranium, thorium, gross alpha and gross beta activities has been assessed in 34 fountains water samples collected from different towns in the Iron Quadrangle. The results obtained were compared to values established by CONAMA nº 396/2008 and Decree nº 2914/2011 by the Ministry of Health. For Th in water consumption there is no value established in the Brazilian legislation and the concentrations in all samples were lower than 0.01 μg L{sup -1}. For uranium, the values ranged from less than 0.002 to 0.61 μg L{sup -1}, and all results were lower than the value allowed of 15 μg L{sup -1} and 30 μg L{sup -1} established by the legislations above, respectively. The results for the radiation levels of gross alpha and gross beta activity in some fountains waters were slightly above the limits (0.5 Bq L{sup -1} and 1.0 Bq L{sup -1}) established by CONAMA nº 396/2008 and Decreet nº 2914/2011, respectively. (author)

  8. Uranium, thorium, gross alpha and gross beta assessment in fountain waters in towns of the Iron Quadrangle, Brazil

    International Nuclear Information System (INIS)

    Ferreira, Claudia A.; Palmieri, Helena E.L.; Menezes, Maria Angela de B.C.; Chaves, Renata D.A.; Dalmazio, Ilza

    2013-01-01

    The Iron Quadrangle region is known worldwide for its diversity, both ores and rock types, which record a long and important period of Earth's history. For thousands of years erosive processes have exposed ancient rocks, Archean and Proterozoic, in this region. The concentration of uranium, thorium, gross alpha and gross beta activities has been assessed in 34 fountains water samples collected from different towns in the Iron Quadrangle. The results obtained were compared to values established by CONAMA nº 396/2008 and Decree nº 2914/2011 by the Ministry of Health. For Th in water consumption there is no value established in the Brazilian legislation and the concentrations in all samples were lower than 0.01 μg L -1 . For uranium, the values ranged from less than 0.002 to 0.61 μg L -1 , and all results were lower than the value allowed of 15 μg L -1 and 30 μg L -1 established by the legislations above, respectively. The results for the radiation levels of gross alpha and gross beta activity in some fountains waters were slightly above the limits (0.5 Bq L -1 and 1.0 Bq L -1 ) established by CONAMA nº 396/2008 and Decreet nº 2914/2011, respectively. (author)

  9. Gross alpha and beta activity analyses in urine-a routine laboratory method for internal human radioactivity detection.

    Science.gov (United States)

    Chen, Xiaowen; Zhao, Luqian; Qin, Hongran; Zhao, Meijia; Zhou, Yirui; Yang, Shuqiang; Su, Xu; Xu, Xiaohua

    2014-05-01

    The aim of this work was to develop a method to provide rapid results for humans with internal radioactive contamination. The authors hypothesized that valuable information could be obtained from gas proportional counter techniques by screening urine samples from potentially exposed individuals rapidly. Recommended gross alpha and beta activity screening methods generally employ gas proportional counting techniques. Based on International Standards Organization (ISO) methods, improvements were made in the evaporation process to develop a method to provide rapid results, adequate sensitivity, and minimum sample preparation and operator intervention for humans with internal radioactive contamination. The method described by an American National Standards Institute publication was used to calibrate the gas proportional counter, and urine samples from patients with or without radionuclide treatment were measured to validate the method. By improving the evaporation process, the time required to perform the assay was reduced dramatically. Compared with the reference data, the results of the validation samples were very satisfactory with respect to gross-alpha and gross-beta activities. The gas flow proportional counting method described here has the potential for radioactivity monitoring in the body. This method was easy, efficient, and fast, and its application is of great utility in determining whether a sample should be analyzed by a more complicated method, for example radiochemical and/or γ-spectroscopy. In the future, it may be used commonly in medical examination and nuclear emergency treatment.Health Phys. 106(5):000-000; 2014.

  10. The calculation of the detection efficiency in the calibration of gross alpha-beta systems

    International Nuclear Information System (INIS)

    Marian Romeo Calin; Ileana Radulescu; Alexandru Erminiu Druker

    2013-01-01

    This paper presents a method for efficiency calibration of a measuring alpha-beta system PROTEAN ORTEC, MPC-2000-DP, using standard radioactive sources. The system is used to measure gross alpha-beta activity concentrations in environmental samples. The calculated efficiencies of detection were subsequently introduced in the system for two working geometries: measuring geometry-gross alpha-beta ε α g = 31,37 ± 0.25 (%)-the alpha efficiency and ε β g 44.94 ± 0.69 (%)-the beta efficiency, where the spillover factor is X talk g = 25.59 ± 0.50 (%) and measuring geometry up alpha-beta ε α u 36.23 ± 0.29 (%)-the alpha efficiency and ε β u = 48.53 ± 0.74 (%)-the beta efficiency, where the spillover factor is X talk u 31.08 ± 0.60 (%). (author)

  11. Monitoring of gross beta radioactivities on water sample environment in the surrounding of kartini reactor at 2011

    International Nuclear Information System (INIS)

    Siswanti; Munandar, A. Aris

    2013-01-01

    Measurement of gross beta radioactivities on water environment were done in the PTAPB BATAN has a goal for routine monitoring, with the result that fill RPL has been made and the result equivalented with quality standard were decided by BAPETEN. The water sample taken as much as 2 liter at 18 area were definited on radius 100 m to 5000 m in the surrounding of kartini reactor, vaporin on electric stove till the volume been ± 10 ml, and than pick out to the aluminium planset and drying on hot plate. Sample in the plancet were counted with a Low Background Counter (LBC) for 30 minutes and accounted of gross beta radioactivity water system. The result of gross beta radioactivity water environment at 2011 has a lowest 009, ± 0,06 Bq/I on Tambak Bayan area at june and in the Janti area highest 0,39 ± 0,08 Bq/ at December. The result still under of quality standard were decided by SK BAPETEN. No. 02/Ka- BAPETEN/V-99 is 0,4 Bq/I. (author)

  12. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Zapata-Garcia, D. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Llaurado, M., E-mail: montse.llaurado@ub.edu [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain); Rauret, G. [Laboratori de Radiologia Ambiental (LRA), Departament de Quimica Analitica, Universitat de Barcelona, Marti i Franques, 1-11 Planta 3, E-08028 Barcelona (Spain)

    2012-04-15

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO{sub 3}, produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: Black-Right-Pointing-Pointer We study the effect of alpha and beta energies on PSA optimisation. Black-Right-Pointing-Pointer The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. Black-Right-Pointing-Pointer We study the effect of pH on the simultaneous determination of gross alpha/beta activities. Black-Right-Pointing-Pointer HNO{sub 3} produces a high amount of misclassification at very low pH. Black-Right-Pointing-Pointer The results improve when HCl is used to adjust the sample to low pH.

  13. The implications of particle energy and acidic media on gross alpha and gross beta determination using liquid scintillation

    International Nuclear Information System (INIS)

    Zapata-García, D.; Llauradó, M.; Rauret, G.

    2012-01-01

    The interaction of humans with radioactivity present in the environment from natural and artificial sources necessitates an evaluation of its risk on human health. Gross alpha and gross beta activities can provide a rapid evaluation of the radioactive content of a sample and can be simultaneously determined by using liquid scintillation counters. However, calibration of the liquid scintillation counter is required and is affected by many factors, such as particle energy and the acidity of the media. This study investigates what effect the particle energy used for calibration has on misclassification and how to account for this misclassification in routine measurements. The variability in measurement produced by the final pH, as well as any acids used in sample treatment, was also studied. These results showed that the most commonly used acid for these types of analyses, HNO 3 , produced a high amount of misclassifications at very low pH. The results improved when HCl was used to adjust the sample to low pH. - Highlights: ► We study the effect of alpha and beta energies on PSA optimisation. ► The optimum PSA shifts to higher values as the alpha energy increases. Beta energies do not affect it. ► We study the effect of pH on the simultaneous determination of gross alpha/beta activities. ► HNO 3 produces a high amount of misclassification at very low pH. ► The results improve when HCl is used to adjust the sample to low pH.

  14. Gross alpha and beta activities in drinking water from Goias State, Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Mingote, Raquel M. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN), Belo Horizonte, MG (Brazil); Nogueira, Regina A.; Costa, Heliana F. da, E-mail: raquel.mingote@cdtn.br, E-mail: rnogueira@cnen.gov.br, E-mail: heliana@cnen.gov.br [Centro Regional de Ciencias Nucleares do Centro-Oeste (CRCN-CO/CNEN), Abadia de Goias, GO (Brazil). Parque Estadual Telma Ortegal

    2017-07-01

    Detection of gross alpha and beta radioactivity is important for a quick surveying of both natural and anthropogenic radioactivity in water. Furthermore, gross alpha and gross beta parameters are included in Brazilian legislation on quality of drinking water. In this work, a low background liquid scintillation spectrometer was used to simultaneously determine gross alpha and gross beta in samples of the public water supplies in the state of Goias, Brazil, during 2010-2015. Sample preparation involved evaporation to concentrate the sample ten-fold. The results indicate that the water meets the radioactivity standards required by the regulations MS 2914/2011 of the Brazilian Department of Health. Concerning the high level of censored observations, a statistical treatment of data was conducted by using analysis methods of censored data to provide a reference value of the gross alpha and beta radioactivity in drinking water from the state of Goias. The estimated typical activities are very low, 0.030 Bq•L{sup -1} and 0.058 Bq•L{sup -1}, respectively. (author)

  15. Determination of the thoron daughter working level by a one gross alpha-count

    International Nuclear Information System (INIS)

    Bigu, J.; Lau, W.K.

    1983-02-01

    A study has been done on the determination of the thoron daughter Working Level, WL(Tn), by a one gross α-count. The relationship between the gross α-count rate per unit of volume of air sampled and WL(Tn), denoted the F-factor, has been investigated as a function of sampling time, elapsed time from the end of the sampling period, i.e., waiting time, and the thoron daughter disequilibrium ratio [ThC]/[ThB]. It has been found that F depends on both the waiting time and [ThC]/[ThB]. If α-count measurements are made at least 300 min after the end of sampling, F changes by less than 10 percent over the full range of theoretical values of [ThC]/[ThB], i.e., from 0 to 1. The F-factor is independent of [ThC]/[ThB] at approximately 215 min after the end of sampling. This feature can be used to determine WL(Tn) with higher accuracy and at least 1.5 hr earlier than is commonly done using other one gross α-count methods reported in the literature

  16. An intercomparison between gross α counting and gross β counting for grab-sampling determination of airborne radon progeny and thoron progeny

    International Nuclear Information System (INIS)

    Papp, Z.

    2006-01-01

    The instantaneous values of the airborne activity concentrations of radon progeny and thoron progeny have been determined 34 times in a closed and windowless room in a cellar using two independent grab-sampling methods in order to compare the performance of the methods. The activity concentration of radon ( 222 Rn) was also measured and it varied between 200 and 650 Bq m -3 . Two samples of radon and thoron progeny were collected simultaneously from roughly the same air volume by filtering. For the first method, the isotopes were collected on membrane filter and gross α counting was applied over several successive time intervals. This method was a slightly improved version of the methods that are applied generally for this reason for decades. For the second method, the isotopes were collected on glass-fibre filter and gross β counts were registered over several time intervals. This other method was developed a few years ago and the above series of measurements was the first opportunity to make an intercomparison between it and another similar method based on α counting. Individual radon progeny and thoron progeny activity concentrations (for the isotopes 218 Po, 214 Pb, 214 Bi and 212 Pb) were evaluated by both methods. The detailed investigation of the results showed that the systematic deviation of the methods is small but significant and isotope-dependent. The weighted averages of the β/α activity concentration ratios for 218 Po, 214 Pb, 214 Bi, EEDC 222 (Equilibrium-Equivalent Decay-product Concentration of radon progeny) and 212 Pb were 0.99±0.03, 0.90±0.02, 1.03±0.02, 0.96±0.02 and 0.80±0.03, respectively. The source of the systematic deviation is probably the inaccurate knowledge of the counting efficiencies mainly in the case of the α-counting method. A significant random-type difference between the results obtained with the two methods has also been revealed. For example, the β/α ratio for EEDC 222 varied between 0.81±0.01 and 1.22±0

  17. Determination of 90Sr, 129I and gross beta radioactivity concentration in some teas

    International Nuclear Information System (INIS)

    Sultan Sahin; Mahmut Dogru

    2011-01-01

    In this study, 90 Sr (540 keVβ - ), 129 I (150 keVβ - ) and the gross beta radioactivity concentrations were determined for the samples of tea as the most leading consumed hot drink in the markets (processed and packaged for sale) in our country. Furthermore, the obtained data were statistically analyzed. For determination of 129 I (150 keVβ - ), 90 Sr (540 keVβ - ) and gross radioactivity concentrations in tea samples, a sensor system consisting of scintillation detector with BP4 probe sensitive to beta radiation and a radiation meter (ST7) configurable for windows at desired power was used. (author)

  18. Monitoring gross alpha and beta activity in liquids by using ZnS(Ag) scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Stevanato, L.; Cester, D.; Filippi, D.; Lunardon, M.; Mistura, G.; Moretto, S.; Viesti, G. [Department of Physics and Astronomy ' Galileo Galilei' , University of Padova, (Italy); Badocco, D.; Pastore, P.; Romanini, F. [Department of Chemical Sciences, University of Padova, (Italy)

    2015-07-01

    In this work the possibility of monitoring gross alpha and beta activity in liquids using EJ-444 was investigated. Specific tests were carried out to determine the change of the detector properties in water tests. Possible protecting coating is also proposed and tested. Alpha/beta real-time monitoring in liquids is a goal of the EU project TAWARA{sub R}TM. (authors)

  19. Standardization and estimation of gross alpha and beta activities for potable water samples in presence of TDS using TDCR based LSA (Hidex 300SL)

    International Nuclear Information System (INIS)

    Gupta, Anil; Lenka, P.; Sahoo, S.K.; Patra, A.C.; Jha, S.K.; Tripathi, R.M.

    2018-01-01

    Quality of water is important in environmental studies because of its daily use for human consumption and an important route of intake for various elements and radionuclides. Therefore radiological quality of drinking water must be ensured. The screening parameter to evaluate the radiological safety of potable water is by estimating gross alpha and gross beta activities with a limit of 0.5 Bq/l and 1 Bq/l respectively. These have been traditionally being done by radiochemical co-precipitation of alpha and beta emitters followed by counting by ZnS(Ag) counter for alpha and gas flow proportional counter for beta. Gross alpha estimation in water samples with high TDS by ZnS(Ag) is difficult and often leads to underestimation of result due to self-absorption of alpha within the residue. This study was carried out to standardize a method to provide rapid results by simultaneously estimating both gross alpha and gross beta activity in the presence of TDS with adequate sensitivity, minimum sample processing

  20. Gross beta activity and the concentration of sup(90)Sr in the vegetables of Daejeon area

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J.Y.; Jun, J.S.; Oh, H.P. (Chungnam National Univ., Taejon (Republic of Korea))

    1984-06-01

    The measurement of gross beta activity and the concentration of sup(90)Sr in the vegetables such as Brassica Campestris, Raphanus Sativus and Lactuca Sativa grown in Daejeon area was carried out during the period of April through August 1983. The observed levels of gross beta activity and the concentration of sup(90)Sr in the levels of the vegetables were, on average, 189.2+-51.8pCi/g-ash (2372+-827pCi/kg-fresh) and 44.4+-11.5sup(90)Sr pCi/g-Ca(2.5+-0.5sup(90) pCi/g-ash or 31.6+-8.6 sup(90)Sr pCi/kg-fresh), respectively, while the mean level of the gross beta activity in roots was 158.6+-19.4pCi/g-ash(2121+-899pCi/kg-fresh). On the basis of the ICRP recommendations, an estimative evaluation was made for the concentration of sup(90)Sr in the vegetables, and it was turned out to be far below the permissible level. An attempt was also made to look for any existing difference in the gross beta, activities of the vegetables grown in vinyl house and in open field, taking seasonal variation of airborne radioactivity into account for normalizing the activity deposited during the course of discrepant farming period.

  1. A manual low background alpha beta counting system

    Energy Technology Data Exchange (ETDEWEB)

    Levison, S; German, U; Peled, O; Turgeman, S; Vangrovitz, U; Tirosh, D; Piestum, S; Assido, H [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    An Alpha and Beta counting system consisting of a micro controller-based electronic unit and detectors assembly was developed. The radiation detection unit consists of two proportional detectors (a main detector and a cosmic-ray guard detector) which can be easily disassembled for decontamination or repair. The detectors are mounted in a manual operating sample changer shielded by 5 cm of lead. Simplicity of maintenance and functional operation were taken into consideration in the design. The electronic unit supplies the high voltage and enables the operational functions including controls anti alarms. Calculations of net cpm of Alpha and Beta counting are displayed and can be printed. RS-232 communication option enables connection to a computer and operation of more sophisticated programs for calculations and data storage in the future (authors).

  2. A manual low background alpha beta counting system

    International Nuclear Information System (INIS)

    Levison, S.; German, U.; Peled, O.; Turgeman, S.; Vangrovitz, U.; Tirosh, D.; Piestum, S.; Assido, H.

    1996-01-01

    An Alpha and Beta counting system consisting of a micro controller-based electronic unit and detectors assembly was developed. The radiation detection unit consists of two proportional detectors (a main detector and a cosmic-ray guard detector) which can be easily disassembled for decontamination or repair. The detectors are mounted in a manual operating sample changer shielded by 5 cm of lead. Simplicity of maintenance and functional operation were taken into consideration in the design. The electronic unit supplies the high voltage and enables the operational functions including controls anti alarms. Calculations of net cpm of Alpha and Beta counting are displayed and can be printed. RS-232 communication option enables connection to a computer and operation of more sophisticated programs for calculations and data storage in the future (authors)

  3. The determination of the national background radioactivity of gross alpha and gross beta in water samples at the PUSPATI site and its neutrons

    International Nuclear Information System (INIS)

    Rahman, M.T.A.

    1983-01-01

    The determination of the natural background radioactivity in water samples has been made at the PUSPATI site and its environs. The study was performed in January 1981 until June 1981. Samples of river, rain and tap water are periodically collected and analyzed in order to determine gross alpha and gross beta activity. In general, the total radioactivity of water is considerably low. The mean concentration of gross alpha in river water and tap water samples are 1.2 +- 0.1 and 0.2 +- 0.1 pCi/ respectively. The level of gross alpha in rain water is however, below the background rate of the detector. The mean concentration of gross beta in river water, tap water and rain water samples are 4.2 +- 0.6, 1.6 +- 0.3, and 1.9 +- 0.3 pCi/ respectively. (author)

  4. Spreadsheet design and validation for characteristic limits determination in gross alpha and beta measurement

    International Nuclear Information System (INIS)

    Prado, Rodrigo G.P. do; Dalmazio, Ilza

    2013-01-01

    The identification and detection of ionizing radiation are essential requisites of radiation protection. Gross alpha and beta measurements are widely applied as a screening method in radiological characterization, environmental monitoring and industrial applications. As in any other analytical technique, test performance depends on the quality of instrumental measurements and reliability of calculations. Characteristic limits refer to three specific statistics, namely, decision threshold, detection limit and confidence interval, which are fundamental to ensuring the quality of determinations. This work describes a way to calculate characteristic limits for measurements of gross alpha and beta activity applying spreadsheets. The approach used for determination of decision threshold, detection limit and limits of the confidence interval, the mathematical expressions of measurands and uncertainty followed standards guidelines. A succinct overview of this approach and examples are presented and spreadsheets were validated using specific software. Furthermore, these spreadsheets could be used as tool to instruct beginner users of methods for ionizing radiation measurements. (author)

  5. Measurement of Gross Alpha and Beta Emission Rates from Ceramic Tiles

    International Nuclear Information System (INIS)

    Wudthicharoonpun, Piyasak; Chankow, Nares

    2007-08-01

    Full text: Ceramic tiles normally used to cover floors and walls contain naturally occurring radioactive elements i.e. potassium-40, uranium, thorium and their daughters from raw materials. Thus, radioactivity was dependent upon source of raw materials and the amount used. The objective of this research was to measure gross alpha and beta emission rates to be used as a database for safety assessment and for selection of rooms to measure radioactive radon-222 gas

  6. The Determination of Gross Alpha And Beta Activity of Drinking Water in Turkey

    International Nuclear Information System (INIS)

    Dilaver, A.T.; Cifter, C.; Altay, T.

    2002-01-01

    Man and his environment must be protected from the adverse effects of pesticides, radiation, noise and other forms of pollutions. Radioactive materials occur naturally in the environment (for example uranium, thorium and potassium). Same radioactive compounds arise from human activities (for example from medical or industrial uses of radioactivity). Drinking water should be safe to use and aesthetically pleasing. World Health Organisation (WHO) and Turkish Standards (TSE) have established maximum contaminant levels for gross alpha and gross beta. The purpose of these study is to determine the level of gross alpha and gross beta activities of samples collected from the different Regional Directories of The State Hydraulic Works (DSI)). After that compare the results versus permissible values of World Health Organisation and Turkish Standards. Collected samples from 14 Regional Directories of The State Hydraulic Works (DSI), have completed. All the analyses results suitable for WHO and TSE. We will give all the research our final report after completed the other Regional Directories' s analyses

  7. Gross theory of beta-decay and half-lives of short-lived nuclei

    International Nuclear Information System (INIS)

    Yamada, Masami; Kondo, Norikatsu.

    1976-01-01

    The gross theory of beta-decay has been developed, and this theory offers the means of calculating directly the function of beta-decay intensity, then half-lives, complex beta spectra and so on are estimated from it. This paper presents the more refined theory by introducing the shell effect. The shell effect is considered in the intensity function. The half-lives in the electron decay of In with spin of 9/2 + , the positron decay of Bi, Po, At and Rn, and the decay of odd-odd nuclei were estimated. The introduction of the shell effect shows better agreement between the theory and the experimental data. The inequality relations of intensity functions and half-lives of two adjacent nuclei were obtained. When the spins and parities of two nuclei are same, the inequality relations hold especially good. (Kato, T.)

  8. PC based alpha, beta and gamma counting system

    International Nuclear Information System (INIS)

    Bhattacharya, S.; Gopalakrishnan, K.R.; Bairi, B.R.

    1992-01-01

    In the field of radiation protection and safety a large number of samples have to be assayed for estimation of their radioactivity at various stages in nuclear fuel. A PC based alpha, beta and gamma counting system has been designed for the above application. The system is fully automatic and requires minimum of operator intervention. The main units in the system are detector and pulse processing electronics, sample changer and assembly and IBM PC interface and supporting software. The main function of interface is to control the sample changer which is basically loading and unloading of sample, data acquisition and further processing by software. The pulses from detector are analysed in a pulse shape discriminator. A pulse identified as an alpha, beta or gamma event is converted to digital pulse. These digital pulses are accumulated in the three channels on PC interface each corresponding to alpha, beta and gamma. The sample movements are controlled by interface depending upon sample position. The software has been developed so as to maintain user friendliness and convenience of the operator. Various selection modes for parameters and operation of system provide lot of flexibility in operation of the system. (author). 1 fig

  9. Passive non destructive assay of hull waste by gross neutron counting method

    International Nuclear Information System (INIS)

    Andola, Sanjay; Sur, Amit; Rawool, A.M.; Sharma, B.; Kaushik, T.C.; Gupta, S.C.; Basu, Sekhar; Raman Kumar; Agarwal, K.

    2014-01-01

    The special nuclear material accounting (SNMA) is an important and necessary issue now in nuclear waste management. The hull waste generated from dissolution of spent fuel contains small amounts of Uranium and Plutonium and other actinides due to undissolved trapped material inside zircoalloy tubes. We report here on the development of a Passive Hull monitoring system using gross neutron counting technique and its implementation with semiautomatic instrumentation. The overall sensitivity of the 3 He detector banks placed at 75 cm from the centre of loaded hull cask comes out to 5.2 x 10 -3 counts per neutron (c/n) while with standard Pu-Be source placed in same position it comes out to be 3.1 x 10 3 c/n. The difference in the efficiency is mainly because of the differences in the geometry and size of hull cask as well as difference in the energy spectrum of hull waste and Pu-Be source. This is accounted through Monte Carlo computations. The Pu mass in solid waste comes out as expected and varies with the surface dose rate of drum in almost a proportional manner. Being simple and less time consuming, this setup has been installed for routine assay of solid Hull waste at NRB, Tarapur

  10. Determining the level of gross alpha and beta radioactivity of water from Marilao river using liquid scintillation counter

    International Nuclear Information System (INIS)

    Cruz, J.; Magtaka, J.; Balisi, R.; Castaneda, Soledad; De Vero, J.

    2009-01-01

    This study aims to determine the level of gross alpha- and beta- radioactivity present in the Marilao River. Liquid Scintillation Counter was used to detect samples radioactivity. Water samples were taken along the different spots of Marilao River. The results showed that the radioactivity are below the Philippine National Standard for Drinking Water (PNSDW) which is 0.1 Bq/L for gross alpha activity and 1.0 Bq/L for gross beta activity set by the Dept. of Health. Hence water samples from Marilao River, is safe in terms of the level of radioactivity levels.(author)

  11. Radon Progenies as a Source of Gross Alpha-beta Activities in Drinking Water in Vinaninkarena, Antsirabe-Madagascar

    International Nuclear Information System (INIS)

    Raoelina Andriambololona; Rabesiranana, N.; Rasolonirina, M.; Rakotomanga, H.

    2004-01-01

    The village of Vinaninkarena, Antsirabe, Madagascar is located in a high radioactivity area. With the aim of assessing the health impact of radioactivity pollution, a survey was conducted around an abandoned radium mining. Waters from 24 sampling points, including 5 wells and 13 springs were sampled. The water radioactivity was measured using a portable Triathler LSC, model 425-034 from Hidex Turku. Each sample is counted more than 3 times: less than 2h after sampling, 4h to few days and more than 3 weeks after when 226 Ra attains equilibrium with 222 Rn and its short-lived daughters. Combination of water non miscible, radon extractive LS cocktail and water miscible one is used to reveal contribution of radium, radon and its short lived progenies to the gross alpha-beta activities. Maximum activity values found are : 3.6±0.3 Bq.L -1 for 226 Ra, 554±9 Bq.L -1 for the excess of radon, and 408±8 Bq.L -1 for the excess of radon progenies. Based on these data, a daily consumption of 2 L of these waters by a standard person would produce an annual 226 Ra ingestion well above the annual intake limit for 226 Ra. Moreover, the increasing gross alpha-beta activity resulting from radon progenies raises the issue of health effects. The potential for rapid spring-to-mouth delivery, which is frequent in rural area, may expose the water consumer to the short-lived alpha particle emitters.

  12. Beta-gamma counting system for Xe fission products

    International Nuclear Information System (INIS)

    Reeder, P.L.; Bowyer, T.W.; Perkins, R.W.

    1998-01-01

    A beta-gamma coincidence counting system has been developed for automated analysis of Xe gas samples separated from air. The Xe gas samples are contained in a cylindrical plastic scintillator cell located between two NaI(Tl) scintillation detectors. The X-ray and gamma spectra gated by coincident events in the plastic scintillator cell are recorded for each NaI(Tl) crystal. The characteristic signatures of the 131m Xe, 133g Xe, 133m Xe, and 135g Xe isotopes of interest for nuclear test-ban verification as well as the procedures and results of absolute efficiency measurements are described. A NaI(Tl) crystal with provision for 4 sample cells has been implemented for the system to be deployed in the field. Examples of data on ambient air samples in New York City obtained with the field prototype are presented. (author)

  13. "Lost milk?": Counting the economic value of breast milk in gross domestic product.

    Science.gov (United States)

    Smith, J P

    2013-11-01

    The contribution of breastfeeding and mothers milk to the economy is invisible in economic statistics. This article demonstrates how the economic value of human milk production can be included in economic statistics such as gross domestic product (GDP) and provides estimates for Australia, the United States, and Norway. The contribution of human milk and lactation to GDP in these countries is estimated using United Nations (System of National Accounting) guidelines and conventional economic valuation approaches to measuring production in GDP. In Australia, current human milk production levels exceed $3 billion annually. The United States has the potential to produce human milk worth more than US$110 billion a year, but currently nearly two thirds of this value is lost due to premature weaning. In Norway, production valued at US$907 million annually is 60% of its potential value. The potential loss of economic value from not protecting women's lactation and milk production from competing market pressures is large. Failure to account for mothers' milk production in GDP and other economic data has important consequences for public policy. The invisibility of human milk reduces the perceived importance of programs and regulations that protect and support women to breastfeed. The value of human milk can be measured using accepted international guidelines for calculating national income and production. It is quantitatively nontrivial and should be counted in GDP.

  14. The gross beta activity and the concentration of sup(90)Sr in the vegetables of Daejeon area

    International Nuclear Information System (INIS)

    Lee, J.Y.; Jun, J.S.; Oh, H.P.

    1984-01-01

    The measurement of gross beta activity and the concentration of sup(90)Sr in the vegetables such as Brassica Campestris, Raphanus Sativus and Lactuca Sativa grown in Daejeon area was carried out during the period of April through August 1983. The observed levels of gross beta activity and the concentration of sup(90)Sr in the levels of the vegetables were, on average, 189.2+-51.8pCi/g-ash (2372+-827pCi/kg-fresh) and 44.4+-11.5sup(90)Sr pCi/g-Ca(2.5+-0.5sup(90) pCi/g-ash or 31.6+-8.6 sup(90)Sr pCi/kg-fresh), respectively, while the mean level of the gross beta activity in roots was 158.6+-19.4pCi/g-ash(2121+-899pCi/kg-fresh). On the basis of the ICRP recommendations, an estimative evaluation was made for the concentration of sup(90)Sr in the vegetables, and it was turned out to be far below the permissible level. An attempt was also made to look for any existing difference in the gross beta, activities of the vegetables grown in vinyl house and in open field, taking seasonal variation of airborne radioactivity into account for normalizing the activity deposited during the course of discrepant farming period. (Author)

  15. Simultaneous and separate, low background counting of beta rays and gamma rays using the phoswich principle

    International Nuclear Information System (INIS)

    Mayhugh, M.R.; Utts, B.K.; Shoffner, B.M.

    1978-01-01

    A phoswich constructed using thin calcium fluoride optically coupled to a thicker sodium iodide crystal and operated with pulse shape analysis equipment can be used as an efficient low background counting assembly. Low background in the beta ray counting channel is achieved by judicious choice of pure materials in the assembly and by operating the analysis equipment so as to reject background events which occur simultaneously in the sodium iodide crystal. Careful survey of construction materials and methods has resulted in reducing beta ray counting background to 0.6 c/min for a 2-inch diameter assembly. The radioactivity of typical building materials will be discussed. A pulse shape analyzer has been constructed which provides separately adjusted time windows and separate output information for the beta ray and gamma ray channels. The dual channel capability combined with the low beta ray background reduces the sample counting time significantly for typical laboratory samples. (author)

  16. Phoswich Detector for Simultaneous Counting of Alpha- and Beta-ray in a Pipe during Decommissioning

    International Nuclear Information System (INIS)

    Seo, B.K.; Kim, G.H.; Woo, Z.H.; Jung, Y.H.; Oh, W.Z.; Lee, K.W.; Han, M.J.

    2006-01-01

    A great quantity of waste has been generated during the decommissioning of nuclear facilities. These wastes are contaminated with various types of alpha, beta, and gamma nuclides. The contamination level of the decommissioning wastes must be surveyed for free release, but it is very difficult to monitor the radioactive contamination level of the pipe inside using conventional counting methods because of the small diameter. In this study a Phoswich detector for simultaneous counting of alpha- and beta-rays in a pipe was developed. The Phoswich detector is convenient for monitoring of alpha and beta contamination using only a single detector, which was composed of thin cylindrical ZnS(Ag) and plastic scintillator. The scintillator for counting an alpha particle has been applied a cylindrical polymer composite sheet, having a double layer structure of an inorganic scintillator ZnS(Ag) layer adhered onto a polymer sub-layer. The sub-layer in an alpha particle counting sheet is made of polysulfone, working as a mechanical and optical support. The ZnS(Ag) layer is formed by coating a ternary mixture of ZnS(Ag), cyano resin as a binder and solvent onto the top of a sub-layer via the screen printing method. The other layer for counting a beta particle used a commercially available plastic scintillator. The plastic scintillator was simulated by using the Monte Carlo simulation method for detection of beta radiation emitted from internal surfaces of small diameter pipe. Simulation results predicted the optimum thickness and geometry of plastic scintillator at which energy absorption for beta radiation was maximized. Characteristics of the detector fabricated were also estimated. As a result, it was confirmed that detector capability was suitable for counting the beta ray. The overall counting results reveal that the developed Phoswich detector is efficient for simultaneous counting of alpha and beta ray in a pipe. (authors)

  17. Design of a Quality Control Program for the Measurement of Gross Alpha and Gross Beta Activities (LMPR-CIEMAT); Diseno del Control de Calidad de las Medidas de Actividad Alfa-Beta Total (LMPR-CIEMAT)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez, A.; Yague, L.; Gasco, C.; Navarro, N.; Higueras, E.; Noguerales, C.

    2010-10-21

    In accordance with international standards, general requirements for testing laboratories have to include a quality system for planning, implementing, and assessing the work performed by the organization and for carrying out required quality assurance and quality control. The purpose of internal laboratory quality control is to monitor performance, identify problems, and initiate corrective actions. This report describes the internal quality control to monitor the gross alpha and beta activities determination. Identification of specific performance indicators, the principles that govern their use and statistical means of evaluation are explained. Finally, calculation of alpha and beta specific activities, uncertainties and detection limits are performed. (Author) 10 refs.

  18. Radionuclide, scintillation cocktail and chemical/color quench influence on discriminator setting in gross alpha/beta measurements by LSC

    International Nuclear Information System (INIS)

    Stojković, Ivana; Tenjović, Branislava; Nikolov, Jovana; Todorović, Nataša

    2015-01-01

    Gross alpha/beta measurements in drinking waters enable radiochemical composition analysis in environmental studies providing efficient screening method that can indicate whether water contains elevated levels of any radionuclide. Routine gross alpha/beta activity monitoring in drinking waters has been carried out for a few years in laboratory for low-level radioactivity measurements in Novi Sad according to ASTM method, performing measurements on liquid scintillation counter Quantulus 1220 which can simultaneously generate alpha/beta spectra of samples by Pulse Shape Analysis (PSA circuit). In this paper, PSA discriminator impact was investigated to ensure obtaining of accurate and reliable alpha/beta activities. One novelty of presented work is PSA parameter setup with two combinations of radionuclides ( 241 Am, 226 Ra and 90 Sr/ 90 Y) with varying activity concentrations. Performed experiments also make contribution to investigations on the manner in which chemical and color quench affect optimal PSA parameter setting and further on, their altogether influence on gross alpha/beta activity measurements. Nitromethane, 15.8 M nitric acid and water, as well as yellow and yellow-orange dye, were used as quenching agents in order to test PSA/interference factor behavior in the presence of quenchers with different quenching strengths. Variation of PSA setting in quenched samples with two different commercially available cocktails (Ultima Gold LLT and OptiPhase HiSafe 3) was also tested. Lastly, application i.e. assessment of obtained PSA-SQP(E) correlation on the obtained results of activity concentrations of few artesian well water samples and colored spiked samples, based on the measured SQP(E) value of samples, has been demonstrated. - Highlights: • Thorough study on influence of relevant factors on optimal PSA level in gross alpha/beta measurements in waters is presented. • Experiments were performed on liquid scintillation counter Quantulus 1220™ according

  19. Mutual interference of alpha and beta signals in counting

    International Nuclear Information System (INIS)

    Zhang Fengxiang; Ren Wei; Tang Shaohua; Han Suping; Du Xiangyang.

    1993-01-01

    When multi-wire proportional counters are used for monitoring of mixed contamination of α and β radioactivity, both of the signals should be distinguished as far as possible from requirement of radiation protection. The rules provided by the recommendation standard of International Electrotechnical Committee (IEC) and the national standard of China indicate: For fixed personal surface contamination monitoring assembly, the response of the α-counting channel to β events should be smaller than 1% of response of the α-counting channel to α events, and the response of β-counting channel to β events should be smaller than that of the response of α-counting channel to the same events. To distinguish one kind of signal from another, amplitude discrimination method is used usually. (3 figs)

  20. Optimization of Counting Times, Figure of Merit and Mass Thickness for Low-background Alpha/beta Proportional Counter in Sea Water

    International Nuclear Information System (INIS)

    Pakkong, Pannee; Wongsanit, Sarinya; Tumnoi, Yutthana; Udomsomporn, Suchin

    2011-06-01

    Full text: The determination of gross alpha and beta activity in environmental aqueous samples can be done by using a low-background alpha/beta proportional counter with multiple detector type (Bert hold LB770). The co precipitate sea water samples were considered for optimal regime of counting time, the minimum detectable activity (MDA), mass thickness of samples (mg/cm-2) and figure of merit (FOM). The result showed that the MDA of the measurements were estimated to be 0.07 Bq/l for gross alpha and 0.05 Bq/l for gross beta at counting time of 100 and 200 minute, respectively. The thickness of samples prepared by coprecipitation technique indicated more parochial range when compared to evaporation to dryness method. In addition, the samples were in the suitable range that can be corrected by the previous self-absorption correction factor (F a ) as 0.0003w 2 -0.0414 w+1.692; where F a is the self-absorption correction factor and w is the weight of the final precipitate in milligrams

  1. Calibration of a liquid scintillation counter for alpha, beta and Cerenkov counting

    International Nuclear Information System (INIS)

    Scarpitta, S.C.; Fisenne, I.M.

    1996-07-01

    Calibration data are presented for 25 radionuclides that were individually measured in a Packard Tri-Carb 2250CA liquid scintillation (LS) counter by both conventional and Cerenkov detection techniques. The relationships and regression data between the quench indicating parameters and the LS counting efficiencies were determined using microliter amounts of tracer added to low 40 K borosilicate glass vials containing 15 mL of Insta-Gel XF scintillation cocktail. Using 40 K, the detection efficiencies were linear over a three order of magnitude range (10 - 10,000 mBq) in beta activity for both LS and Cerenkov counting. The Cerenkov counting efficiency (CCE) increased linearly (42% per MeV) from 0.30 to 2.0 MeV, whereas the LS efficiency was >90% for betas with energy in excess of 0.30 MeV. The CCE was 20 - 50% less than the LS counting efficiency for beta particles with maximum energies in excess of 1 MeV. Based on replicate background measurements, the lower limit of detection (LLD) for a 1-h count at the 95% confidence level, using water as a solvent, was 0.024 counts sec- -1 and 0.028 counts sec-1 for plastic and glass vials, respectively. The LLD for a 1-h-count ranged from 46 to 56 mBq (2.8 - 3.4 dpm) for both Cerenkov and conventional LS counting. This assumes: (1) a 100% counting efficiency, (2) a 50% yield of the nuclide of interest, (3) a 1-h measurement time using low background plastic vials, and (4) a 0-50 keV region of interest. The LLD is reduced an order of magnitude when the yield recovery exceeds 90% and a lower background region is used (i.e., 100 - 500 keV alpha region of interest). Examples and applications of both Cerenkov and LS counting techniques are given in the text and appendices

  2. High Sensitivity Detection of Xe Isotopes Via Beta-Gamma Coincidence Counting

    International Nuclear Information System (INIS)

    Bowyer, Ted W.; McIntyre, Justin I.; Reeder, Paul L.

    1999-01-01

    Measurement of xenon fission product isotopes is a key element in the global network being established to monitor the Comprehensive Nuclear-Test-Ban Treaty. Pacific Northwest National Laboratory has developed an automated system for separating Xe from air which includes a beta-gamma counting system for 131mXe, 133mXe, 133Xe, and 135Xe. Betas and conversion electrons are detected in a plastic scintillation cell containing the Xe sample. The counting geometry is nearly 100% for beta and conversion electrons. The resolution in the pulse height spectrum from the plastic scintillator is sufficient to observe distinct peaks for specific conversion electrons. Gamma and X-rays are detected in a NaI(Tl) scintillation detector which surrounds the plastic scintillator sample cell. Two-dimensional pulse height spectra of gamma energy versus beta energy are obtained. Each of the four xenon isotopes has a distinctive signature in the two-dimensional energy array. The details of the counting system, examples of two-dimensional beta-gamma data, and operational experience with this counting system will be described

  3. Determination of potassium in feldspars by beta counting using a GM multicounter system

    Energy Technology Data Exchange (ETDEWEB)

    Boetter-Jensen, L; Mejdahl, V

    1985-01-01

    A gas flow multicounter system developed at Risoe National laboratory for low-level beta counting applications was adopted for measuring potassium in feldspars extracted from archaeological and geological materials, in connection with TL dating work. A guard counter reduces the background by using an anticoincidence technique. Calibration was accomplished by measuring KCl and a feldspar standard. A potassium content of 1% yields a net beta count rate (background subtracted) of about 40 c.p.h.; the background is around 15 c.p.h. The precision in repeated measurements is better than 2% and the estimated accuracy is about 3%.

  4. Improving gross count gamma-ray logging in uranium mining with the NGRS probe

    Directory of Open Access Journals (Sweden)

    Carasco C.

    2018-01-01

    Full Text Available AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration measurement by means of gamma ray logging. The determination of uranium concentration in boreholes is performed with the Natural Gamma Ray Sonde (NGRS based on a NaI(Tl scintillation detector. The total gamma count rate is converted into uranium concentration using a calibration coefficient measured in concrete blocks with known uranium concentration in the AREVA Mines calibration facility located in Bessines, France. Until now, to take into account gamma attenuation in a variety of boreholes diameters, tubing materials, diameters and thicknesses, filling fluid densities and compositions, a semi-empirical formula was used to correct the calibration coefficient measured in Bessines facility. In this work, we propose to use Monte Carlo simulations to improve gamma attenuation corrections. To this purpose, the NGRS probe and the calibration measurements in the standard concrete blocks have been modeled with MCNP computer code. The calibration coefficient determined by simulation, 5.3 s-1.ppmU-1 ± 10%, is in good agreement with the one measured in Bessines, 5.2 s-1.ppmU-1. Based on the validated MCNP model, several parametric studies have been performed. For instance, the rock density and chemical composition proved to have a limited impact on the calibration coefficient. However, gamma self-absorption in uranium leads to a nonlinear relationship between count rate and uranium concentration beyond approximately 1% of uranium weight fraction, the underestimation of the uranium content reaching more than a factor 2.5 for a 50 % uranium weight fraction. Next steps will concern parametric studies with different tubing materials, diameters and thicknesses, as well as different borehole filling fluids representative of real measurement conditions.

  5. Improving gross count gamma-ray logging in uranium mining with the NGRS probe

    Science.gov (United States)

    Carasco, C.; Pérot, B.; Ma, J.-L.; Toubon, H.; Dubille-Auchère, A.

    2018-01-01

    AREVA Mines and the Nuclear Measurement Laboratory of CEA Cadarache are collaborating to improve the sensitivity and precision of uranium concentration measurement by means of gamma ray logging. The determination of uranium concentration in boreholes is performed with the Natural Gamma Ray Sonde (NGRS) based on a NaI(Tl) scintillation detector. The total gamma count rate is converted into uranium concentration using a calibration coefficient measured in concrete blocks with known uranium concentration in the AREVA Mines calibration facility located in Bessines, France. Until now, to take into account gamma attenuation in a variety of boreholes diameters, tubing materials, diameters and thicknesses, filling fluid densities and compositions, a semi-empirical formula was used to correct the calibration coefficient measured in Bessines facility. In this work, we propose to use Monte Carlo simulations to improve gamma attenuation corrections. To this purpose, the NGRS probe and the calibration measurements in the standard concrete blocks have been modeled with MCNP computer code. The calibration coefficient determined by simulation, 5.3 s-1.ppmU-1 ± 10%, is in good agreement with the one measured in Bessines, 5.2 s-1.ppmU-1. Based on the validated MCNP model, several parametric studies have been performed. For instance, the rock density and chemical composition proved to have a limited impact on the calibration coefficient. However, gamma self-absorption in uranium leads to a nonlinear relationship between count rate and uranium concentration beyond approximately 1% of uranium weight fraction, the underestimation of the uranium content reaching more than a factor 2.5 for a 50 % uranium weight fraction. Next steps will concern parametric studies with different tubing materials, diameters and thicknesses, as well as different borehole filling fluids representative of real measurement conditions.

  6. Analysis of a Gross Counting Decision Metric for use in Threat Detection During Cargo Container Inspection

    International Nuclear Information System (INIS)

    Hall, J

    2006-01-01

    LLNL is actively engaged in the development of a variety of advanced technologies for use in detecting potential threats in sea-going cargo containers, particularly the presence of hidden special nuclear materials (SNM). One such project is the so-called ''Nuclear Car Wash'' (NCW), which uses a high-energy neutron probe to scan the container. High-energy, β-delayed γ-rays emitted during the decay of short-lived, neutron-induced fission products are then taken as a signature of fissionable material. There are a number of different threat decision metrics that one could imagine using in conjunction with an inspection system such as the NCW; however, the most straightforward approach might be to simply compare the total number of counts that our detector records during some suitably chosen time interval to the average background signal that one would expect from a ''clean'' container during the same interval. The purpose of this report is to describe the basic statistical properties of a decision metric of this sort and outline the procedures for using it in experimental practice

  7. Determination of Potassium in Feldspars by Beta Counting Using a GM Multicounter System

    DEFF Research Database (Denmark)

    Bøtter-Jensen, Lars; Mejdahl, V.

    1985-01-01

    A gas flow multicounter system developed at Riso National Laboratory for low-level beta counting applications was adopted for measuring potassium in feldspars extracted from archaeological and geological materials, in connection with TL dating work. A guard counter reduces the background by using...

  8. Improvement of gross theory of beta-decay for application to nuclear data

    Science.gov (United States)

    Koura, Hiroyuki; Yoshida, Tadashi; Tachibana, Takahiro; Chiba, Satoshi

    2017-09-01

    A theoretical study of β decay and delayed neutron has been carried out with a global β-decay model, the gross theory. The gross theory is based on a consideration of the sum rule of the β-strength function, and gives reasonable results of β-decay rates and delayed neutron in the entire nuclear mass region. In a fissioning nucleus, neutrons are produced by β decay of neutron-rich fission fragments from actinides known as delayed neutrons. The average number of delayed neutrons is estimated based on the sum of the β-delayed neutron-emission probabilities multiplied by the cumulative fission yield for each nucleus. Such a behavior is important to manipulate nuclear reactors, and when we adopt some new high-burn-up reactors, properties of minor actinides will play an important roll in the system, but these data have not been sufficient. We re-analyze and improve the gross theory. For example, we considered the parity of neutrons and protons at the Fermi surface, and treat a suppression for the allowed transitions in the framework of the gross theory. By using the improved gross theory, underestimated half-lives in the neutron-rich indium isotopes and neighboring region increase, and consequently follow experimental trend. The ability of reproduction (and also prediction) of the β-decay rates, delayed-neutron emission probabilities is discussed. With this work, we have described the development of a programming code of the gross theory of β-decay including the improved parts. After preparation finished, this code can be released for the nuclear data community.

  9. Improvement and automatization of a proportional alpha-beta counting system - FAG

    International Nuclear Information System (INIS)

    German, U.; Levinson, S.; Pelled, O.; Shemesh, Y.; Assido, H.

    1997-01-01

    An alpha and beta counting system - FAG*, for planchette samples is operated at the Health Physics department's laboratory of the NRCN. The original operation mode of the system was based on manual tasks handled by the FHT1 100 electronics. An option for a basic computer keyboard operation was available too. A computer with an appropriate I/O card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. A bar-code laser system for sample number reading was integrated into the Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. authors)

  10. One-loop beta functions for the orientable non-commutative Gross Neveu model TH1"-->

    Science.gov (United States)

    Lakhoua, A.; Vignes-Tourneret, F.; Wallet, J.-C.

    2007-11-01

    We compute at the one-loop order the β-functions for a renormalisable non-commutative analog of the Gross Neveu model defined on the Moyal plane. The calculation is performed within the so called x-space formalism. We find that this non-commutative field theory exhibits asymptotic freedom for any number of colors. The β-function for the non-commutative counterpart of the Thirring model is found to be non vanishing.

  11. A bar-code reader for an alpha-beta automatic counting system - FAG

    International Nuclear Information System (INIS)

    Levinson, S.; Shemesh, Y.; Ankry, N.; Assido, H.; German, U.; Peled, O.

    1996-01-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors)

  12. A bar-code reader for an alpha-beta automatic counting system - FAG

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, S; Shemesh, Y; Ankry, N; Assido, H; German, U; Peled, O [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    A bar-code laser system for sample number reading was integrated into the FAG Alpha-Beta automatic counting system. The sample identification by means of an attached bar-code label enables unmistakable and reliable attribution of results to the counted sample. Installation of the bar-code reader system required several modifications: Mechanical changes in the automatic sample changer, design and production of new sample holders, modification of the sample planchettes, changes in the electronic system, update of the operating software of the system (authors).

  13. Low background gas flow beta counting system [Paper No.:M2

    International Nuclear Information System (INIS)

    Abani, M.C.; Anilkumar, S.; Bhende, D.R.; Krishnan, Narayani; Babu, D.A.R.

    1993-01-01

    It is difficult to count beta samples of low specific activity in conventional types of counting systems which have inherently high background. This is specially true in case of environmental samples. A gas flow type beta counter has been developed which have the twin advantage of high efficiency and low background. This system uses a gas flow type main counter and another gas flow type guard counter working on the same principle in anticoincidence mode. Both counters are operated in G.M. region. With this anticoincidence arrangement and lead shielding of 3 inch, the system has the background of the order of 1 cpm and efficiency of 40% for 40 K beta and 14% for 14 C beta. The electronics developed includes a quenching cum coincidence-anticoincidence unit, EHT and a counter timer. This paper describes in detail the development and operational experience with the system. A number of units are already operational at BARC and at Environmental Survey Laboratories set up by Department of Atomic Energy and at various other institutions. (author). 4 refs., 2 figs

  14. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system

    International Nuclear Information System (INIS)

    Carlos, J. E. de; Granados, C. E.

    1972-01-01

    In 4π β-γ coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between theβ--and γ-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs

  15. Investigation and study of radioactive dusts in high altitude air. Consideration on the long-term trends of gross beta activity

    International Nuclear Information System (INIS)

    Ogino, Kumiko; Sato, Mihoko

    2005-01-01

    The data for radioactivities of airborne dust that have been measured by JDA since 1961 was stored in database. Generally, the gross beta activity that have been obtained in the past was analyzed, using the data base. The behavior of fallout in environment and the effect on Japanese sky were considered. (author)

  16. Selection of the ''best'' model for converting beta backscatter count readings into thickness measurements

    International Nuclear Information System (INIS)

    Smiriga, N.G.

    1976-01-01

    This report compares two models for converting beta backscatter count readings into thickness measurements. The necessary formulas to be used in an unweighted and weighted regression analysis are listed. The question of whether one should perform a regression analysis using the five available standard thicknesses or whether one should, in addition to these standard thicknesses, use zero as a standard thickness is decided. A weighted regression analysis is compared with an unweighted one for each model. The ''best'' model is selected, and the conclusions of the analysis are presented

  17. Analysis of fresh fallout from Chinese tests by beta counting technique

    International Nuclear Information System (INIS)

    Mishra, U.C.; Lalit, B.Y.; Shukla, V.K.; Ramachandran, T.V.

    1979-01-01

    The paper describes beta counting techniques used in the analysis of fresh radioactive fallout samples from nuclear weapon tests. Fresh fallout samples have been collected by swiping the exposed portion of the engine covers of commercial aircrafts arriving at Bombay from New York after Chinese tests on September 26, 1976 and September 17, 1977. Activities of short-lived radionuclides such as Ag 111, Sr 89, Mo 99, U 237 and Np 239 were determined using these techniques. The results obtained from this analysis is discussed in brief in relation to the kind of fissile material, the extent of thermonuclear reaction in the weapon and the mode of detonation. (orig.) [de

  18. Role of quenching on alpha/beta separation in liquid scintillation counting for several high capacity cocktails

    International Nuclear Information System (INIS)

    Pujol, L.; Sanchez-Cabeza, J.-A.

    1997-01-01

    The optimization of alpha/beta separation in liquid scintillation using pulse shape analysis is convenient for the simultaneous determination of alpha and beta emitters in natural water and other samples. In this work, alpha/beta separation was studied for different scintillant/vial combinations and it was observed that both the optimum pulse shape discrimination level and the total interference value (that is, the summed relative interference between alpha and beta spectra) were dependent on the sample quenching and independent of the scintillant/vial combination. These results provide a simple method for modifying the counting configuration, such as a change in the cocktail, vial or sample characteristics, without the need to perform exhaustive parameter optimizations. Also, it was observed that, for our counting conditions, the combination of Ultima Gold AB scintillation cocktail with Zinsser low diffusion vials presented the lowest total interference, namely 0.94 ± 0.28%, which is insignificant for the counting of environmental samples. (Author)

  19. Identification and quantitative grade estimation of Uranium mineralization based on gross-count gamma ray log at Lemajung sector West Kalimantan

    International Nuclear Information System (INIS)

    Adi Gunawan Muhammad

    2014-01-01

    Lemajung sector, is one of uranium potential sector in Kalan Area, West Kalimantan. Uranium mineralization is found in metasiltstone and schistose metapelite rock with general direction of mineralization east - west tilted ± 70° to the north parallel with schistocity pattern (S1). Drilling evaluation has been implemented in 2013 in Lemajung sector at R-05 (LEML-(S1). Drilling evaluation has been implemented in 2013 in Lemajung sector at R-05 (LEML-gamma ray. The purpose of this activity is to determine uranium mineralization grade with quantitatively methode in the rocks and also determine the geological conditions in sorounding of drilling area. The methodology involves determining the value of k-factor, geological mapping for the sorounding of drill hole, determination of the thickness and grade estimation of uranium mineralization with gross-count gamma ray. Quantitatively from grade estimation of uranium using gross-count gamma ray log can be known that the highest % eU_3O_8 in the hole R-05 (LEML-40) reaches 0.7493≈6354 ppm eU found at depth interval from 30.1 to 34.96 m. Uranium mineralization is present as fracture filling (vein) or tectonic breccia matrix filling in metasiltstone with thickness from 0.10 to 2.40 m associated with sulphide (pyrite) and characterized by high ratio of U/Th. (author)

  20. Refinement of the gross theory of nuclear {beta}-decay, and hindrance of the first-forbidden transition of rank 1

    Energy Technology Data Exchange (ETDEWEB)

    Nakata, Hidehiko [Waseda Univ., Tokyo (Japan). Dept. of Physics; Tachibana, Takahiro; Yamada, Masami

    1997-03-01

    Recently the gross theory of nuclear {beta}-decay was refined for odd-odd nuclei. In this refinement, the effect of the selection rule of {beta}-transitions from the ground states of odd-odd nuclei to those of even-even nuclei was taken into account based on a statistical consideration. The transitions to the first 2{sup +} excited states in even-even nuclei were also taken into account according to the selection rule approximately. In that study, it was found that the transitions between 1{sup -} ground states of the odd-odd nuclei and 0{sup +} ground states of even-even nuclei, belonging to the first-forbidden transitions of rank 1, are strongly hindered. A reduction factor was introduced for the transitions to the ground states of even-even nuclei to take into account this hindrance. It was also found that the strength functions of the Gamow-Teller transitions obtained from the conventional gross theory are underestimated by a factor of about 3. In order to improve this underestimation, the Lorentz-type function was adopted for the one-particle strength function in the model instead of the hyperbolic-secant-type function. In the present study we have newly analyzed the experimental ft-values of odd-A nuclei, and found that the first-forbidden transitions of rank 1 are also considerably hindered between the ground states. Following the above refinement we have calculated the {beta}-ray spectra of some odd-odd short-lived fission products with the use of the refined gross theory. These results are compared not only with the experiments by Rudstam et al. but also with the conventional gross theory. (author)

  1. Evaluation of induced radioactivity in 10 MeV-Electron irradiated spices, (2); [beta]-ray counting

    Energy Technology Data Exchange (ETDEWEB)

    Katayama, Tadashi; Furuta, Masakazu; Shibata, Setsuko; Matsunami, Tadao; Ito, Norio; Mizohata, Akira; Toratani, Hirokazu (Osaka Prefectural Univ., Sakai (Japan). Research Inst. for Advanced Science and Technology); Takeda, Atsuhiko

    1994-02-01

    In order to check radioactivity of beta-emmitters produced by ([gamma], n) reactions which could occur at energies up to 10 MeV, black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeV electron from a linear accelerator to a dose of 100 kGy. Beta-rays were counted using a 2[pi] gas flow counter and a liquid scintillation counter. Any induced radioactivity could not be detected in irradiated samples. When inorganic compounds containing the nuclides in the list were artificially added in the samples and were irradiated, the [beta]-activities were detected. From the amount of observed radioactivities of [beta]-emmitters produced in the compounds as photonuclear products, it is concluded that the induced radioactivity in natural samples by 10 MeV-electron irradiation were far smaller than natural radioactivity from [sup 40]K contained in the samples and, hence, its biological effects should be negligible. (author).

  2. Operating program for an automatic alpha-beta counting system-FAG

    International Nuclear Information System (INIS)

    German, U.; Levinson, L.; Shemesh, Y.; Peled, O.; Weistein, M.

    1996-01-01

    An alpha and beta counting system - FAG, for planchette samples is operated at the Health Physics department's laboratory of the NRCN. The system consists of a proportional detector of 8'' diameter operated in coincidence with a guard detector, an automatic sample changer (FAG-FHT770E) and electronics (FAG- FHT1100 digital counter and controller). The original operation mode of the system was based on manual tasks handled by the FHT1100 electronics. Pin option for a basic computer keyboard operation was available too. A computer with appropriate 110 card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. The program which was developed enables computer control of all components of the system, based on bi-directional communication. The computer software controls the FHT1100 electronics using the R5232 protocol and the sample changer by an additional 110 card Contec Inodel PIO-48W(PC). The computer controls the whole operation of the system: change of samples, high voltage change, start, stop etc. It handles in the appropriate order the different commands and operates the electronic and mechanic components accordingly (authors)

  3. Operating program for an automatic alpha-beta counting system-FAG

    Energy Technology Data Exchange (ETDEWEB)

    German, U; Levinson, L; Shemesh, Y; Peled, O; Weistein, M [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    An alpha and beta counting system - FAG, for planchette samples is operated at the Health Physics department`s laboratory of the NRCN. The system consists of a proportional detector of 8`` diameter operated in coincidence with a guard detector, an automatic sample changer (FAG-FHT770E) and electronics (FAG- FHT1100 digital counter and controller). The original operation mode of the system was based on manual tasks handled by the FHT1100 electronics. Pin option for a basic computer keyboard operation was available too. A computer with appropriate 110 card was connected to the system and a new operating program was developed which enables full automatic control of the various components. The program includes activity calculations and statistical checks as well as data management. The program which was developed enables computer control of all components of the system, based on bi-directional communication. The computer software controls the FHT1100 electronics using the R5232 protocol and the sample changer by an additional 110 card Contec Inodel PIO-48W(PC). The computer controls the whole operation of the system: change of samples, high voltage change, start, stop etc. It handles in the appropriate order the different commands and operates the electronic and mechanic components accordingly (authors).

  4. Assessment of radiological risk parameters associated with some selected rivers around oil mineral producing sites in Abia State, Nigeria due to gross alpha and beta radiations

    International Nuclear Information System (INIS)

    Enyinna, Paschal Ikenna; Uzochukwu, Francis C.

    2016-01-01

    The study of gross alpha and beta radiation in environmental components and water bodies in particular is very crucial to the environmental, radiation and medical Physicist as this helps to promote good water quality and environmental hygiene. This research work understudied the radiological risk parameters due to gross alpha and beta radiations associated with three selected rivers around crude oil production sites in Abia State, Nigeria. Gross alpha and beta activities were computed for the three rivers based on analytical measurements carried out using a well-calibrated IN-20 model gas-flow proportional counter. Radiological risk parameters were computed from the activity concentrations which included; annual effective dose equivalent of radiation from ingested water (AEDE), annual gonadal dose equivalent (AGDE), and excess lifetime cancer risk (ELCR). The mean of the total AEDE due to the sum of alpha and beta radiations for the three rivers are 0.868 ± 0.221 mSv/y, 1.008 ± 0.156 mSv/y, and 0.917 ± 0.214 mSv/y; and are above the World Health Organization (WHO) permissible limit of 0.1 mSv/y. The mean of the total AGDE are 4.048 ± 1.063 mSv/y, 4.756 ± 0.739 mSv/y, and 4.295 ± 1.026 mSv/y; and are above the world average limit of 0.3 mSv/y. The mean of the total ELCR are (3.038 ± 0.774) X 10"-"3, (3.529 ± 0.547) X 10"-"3, and (3.210 ± 0.748) X 10"-"3; and are above the world average limit of 0.29 X 10"-"3. Most values of ELCR computed in this work are >6.0 X 10"-"4 estimated to be the risk of fatal and weighted nonfatal health conditions over a lifetime (70 years) derived from the radiation dose of 0.1 mSv/y (WHO permissible limit for drinking water). Drinking water from these surveyed sources could impact negatively on the end users. (author)

  5. Few remarks on the absolute counting of {beta} emitters using 4 {pi} counter; Quelques remarques sur la mesure absolue des emetteurs {beta} au compteur 4 {pi}

    Energy Technology Data Exchange (ETDEWEB)

    Grinberg, B; Le Gallic, Y [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    This study looks to determinate the optimum experimental conditions which allow the best accuracy possible for the absolute counting of {beta} emitters when using a 4 {pi} counter. The study has been done with a 4 {pi} counter using source supports of 30 {mu}m thickness. The associated electronic circuit includes: high-voltage, a 1000 scale and a dead time preafier of 4x10{sup -4} {mu}s. In addition, a coincidence preamplifier - with 1 {mu}s resolution time - was added which permits to count the coincidence between the measuring channels. It compares the measurement accuracy and the absorption correction needed for different source supports including polymers thin films with and without metal coating. (M.P.)

  6. Gamma-spectrometric and total alpha-beta counting methods for radioactivity analysis of deuterium depleted water

    International Nuclear Information System (INIS)

    Ferdes, Ov. S.; Mladin, C.; Vladu, Mihaela; Bulubasa, G.; Bidica, N.

    2008-01-01

    According to national regulations, as well as to the EU directive on the quality of drinking water, the radionuclide concentrations represent some of the drinking water quality parameters. Among the most important radioactivity content parameters are: the total alpha and total beta concentration (Bq/l); K-40 content, and the gamma-nuclides volume activities. The paper presents the measuring methods for low-level total alpha and/or beta counting of volume samples, as well as the high-resolution gamma-ray spectrometric method used to measure the volume activity of nuclides in drinking water. These methods are applied to monitor the radioactivity content and quality of the QLARIVIA brand of Deuterium depleted water (DDW). There are discussed the performances of these applied methods as well as some preliminary results. (authors)

  7. Measurement of isotopic uranium in water for compliance monitoring by liquid scintillation counting with alpha/beta discrimination

    International Nuclear Information System (INIS)

    Venso, E.A.S.

    1993-01-01

    A simple and inexpensive method is described for analysis of uranium (U) activity and mass in water by liquid scintillation counting using α/β discrimination. This method appears to offer a solution to the need for an inexpensive protocol for monitoring U activity and mass simultaneously and an alternative to the potential inaccuracy involved when depending on the mass-to-activity conversion factor or activity screen. U is extracted virtually quantitatively into 20 ml extractive scintillator from a 1-ell aliquot of water acidified to less than pH 2. After phase separation, the sample is counted for a 20-minute screening count with a minimum detection level of 0.27 pCi ell -1 . α-particle emissions from the extracted U are counted with close to 100% efficiency with a Beckman LS6000 LL liquid scintillation counter equipped with pulse-shape discrimination electronics. Samples with activities higher than 10 pCi ell -1 are recounted for 500-1000 minutes for isotopic analysis. Isotopic analysis uses events that are automatically stored in spectral files and transferred to a computer during assay. The data can be transferred to a commercially available spreadsheet and retrieved for examination or data manipulation. Values for three readily observable spectral features can be rapidly identified by data examination and substituted into a simple formula to obtain 234 U/ 238 U ratio for most samples. U mass is calculated by substituting the isotopic ratio value into a simple equation. The utility of this method for the proposed compliance monitoring of U in public drinking water supplies was field tested with a survey of drinking water from Texas supplies that had previously been known to contain elevated levels of gross α activity. U concentrations in 32 samples from 27 drinking water supplies ranged from 0.26 to 65.5 pCi ell -1 , with seven samples exceeding the proposed Maximum Contaminant Level

  8. Simple counting technique for measuring mixtures of two pure beta-emitting radionuclides

    CSIR Research Space (South Africa)

    Van Wyngaardt, WM

    2006-08-01

    Full Text Available on counting statistics. The method is demonstrated experimentally for various mixture combinations of C-14 and Ni-63. It is shown that the accuracy of the technique can be enhanced by improving the determination of the figure-of-merit....

  9. Counting efficiency for radionuclides decaying by beta and gamma-ray emission; Calculo de la eficiencia de recuento de nucleidos que experimentan desintegracion beta y desexcitacion gamma simple

    Energy Technology Data Exchange (ETDEWEB)

    Grau, A.; Garcia-Torano, E.

    1988-07-01

    In this paper, counting efficiency vs figure of merit for beta and gamma-ray emitters has been computed. It is assumed that the decay scheme has only a gamma level and the beta-ray emission may be coincident with the gamma-rays or the internal-conversion electrons. The radionuclides tabulated are: 20 {sub 0}, 20{sub p}, 28{sub A}l, 35{sub p}, 41{sub A}r, 42{sub K}, 47{sub S}e, 62{sub F}e, 66{sub C}u, 81{sub G}e, 86{sub B}b, 108{sub R}u, 112{sub p}d, 121{sub S}n(Ni), 122{sub I}n, 129{sub I}, 141{sub C}e 171{sub T}m, 194{sub O}s, 2O3{sub H}g, 205{sub H}g, 210{sub p}b, 225{sub R}a, 142{sub p}r, 151{sub S}m, 244{sub A}m(m). It has been assumed that the liquid is a toluene based scintillator solution in standard glass vials containing 10 cm''3. (Author) 8 refs.

  10. Potassium analysis by beta counting using a Geiger-Mueller system

    International Nuclear Information System (INIS)

    Espana, E.; Beneitez, P.; Calderon, T.

    1993-01-01

    A technique for quantitative analysis of different soils, ceramics, feldspars and natural halide samples is presented, based on the measurement of β-activities using a Geiger-Mueller system. The system was calibrated with KCl, KC 8 H 5 O 4 , KNO 3 and K 2 SO 4 standards and a potassium content of 1% yields a net β-count rate (background subtracted) of about 55 cph. Precision values of less than ±0.4% K can be achieved in counting times of about 4 hours. The results agree with those obtained by means of other more common analytical methods such as flame photometry, atomic absorption and γ-spectrometry. In comparison with these methods, this approach is direct, precise and non-destructive, because the samples do not require prior treatment. (author) 16 refs.; 2 figs.; 6 tabs

  11. Estimation of inhalation doses from airborne releases using gross monitors

    International Nuclear Information System (INIS)

    Goldstein, N.P.

    1978-01-01

    Monitoring programs at most nuclear facilities involve continuous gross measurements supplemented by periodic isotopic analyses of release samples. The isotopic measurements are required to accurately assess the potential dose from the various effluent streams, but in between these measurements, one depends on the gross monitors to provide approximate indications of the dose. The effluent streams release a variety of nuclides, each with its own dose factor. This means that the relationship between the counting rate in a gross monitor and the potential dose of the effluent being monitored will depend on the isotopic composition of this release. If this composition changes, then the dose indicated by the gross monitor (calibrated for the original group of isotopes) may be significantly in error. The problem of indicating inhalation doses from gross monitoring of airborne releases is considered. In order for this type of monitor to accurately indicate dose, regardless of the isotopic makeup of a release, the analysis shows that its response to each isotope should be proportional to the dose factor of that isotope. These ideas are applied to the monitoring of air particulates using gross beta and gross gamma monitors. The study shows that the former more closely satisfies this condition and as a result, satisfactorily indicates the actual dose from reactor effluents, as determined from detailed isotopic data published in the literature. On the other hand, the gross gamma monitor, with its poorer fit to the condition, provided less than satisfactory accuracy in its dose estimates. In addition, a variety of other mathematical response functions were considered but their dose estimation capabilities were not much better than the straight beta response. The study shows that reasonably accurate dose estimates can be made using properly selected gross monitors, but that significant errors can result with improper ones. (author)

  12. Beta, gamma contamination analysis of thermo luminescence dosimeter cassettes using Geiger Muller counting set up and gamma spectrometry techniques

    International Nuclear Information System (INIS)

    Prasad, S.K.; Sudheer, T.S.; Sahoo, L.; Vinayagam, Bhakti; Kamble, Mahesh; Khuspe, R.R.; Anilkumar, Rekha; Verma, K.K.

    2009-01-01

    Β-γ contamination cheek up of TLD cassettes were carried out and the isotopes found were 137 Cs, 106 Ru, 60 Co, 64 Cu, 144 Ce and 95 Nb with activity per square cm varying from 0.05-4.70 Bq/cm 2 with median value 1.3. The assessed dose in TLD was in the range of 2.10 mSv to 22.05 mSv for beta, 0.05 mSv to 5.25 mSv for gamma. The beta doses have median value of 6.19 mSv. This contamination may be due to active water contamination on TLD's of personnel working for irradiated fuel handling or work in fuel rod (under water) storage area. This gives a method to estimate skin exposure of personnel due to skin contamination during work. Chances of getting TLD's contaminated due to various reasons were studied. Contamination was found maximum inside the cassette box having area 16 cm 2 . In case of plastic pouch of TLD disc contamination was detected in three cases. Contamination level on TLD cassettes using GM counter was found in the range of 0.30-3.6 Bq/cm 2 for cassettes. By opening the window of the surveymeter contamination and field of these cassettes in closed condition were found to increase by 20% due to the measurement of beta dose. With the same condition contamination of TLD cassette in open condition was found five times more. This is due to the a-contamination which is five times more than a contamination, The most prominent isotope 137 Cs in common chemical forms are soluble in water and if inhaled or ingested are rapidly and completely absorbed in the lungs and across the gastrointestinal tract. Thus a skin contamination of most prominent isotope 137 Cs can lead to intake in addition to skin dose. Fading studies of contamination of TLD cassettes were carried out. It was found negligible after counting with GM counting set up after a period of 3 months. But one of the TLD cassettes was showing an 80% reduction of contamination after 3 months with GM counting set up, the contaminants being 141 Ce, 103 Ru and 95 Nb. The gamma peaks in the external exposure

  13. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system; Informe preliminar del sistema Samar sistema automatico de medidas absolutas de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Carlos, J E. de; Granados, C E

    1972-07-01

    In 4{pi} {beta}-{gamma} coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between the{beta}--and {gamma}-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs.

  14. A new approach to beta-gamma coincidence counting. Advance report on the Samar electronic system; Informe preliminar del sistema Samar sistema automatico de medidas absolutas de Radionucleidos

    Energy Technology Data Exchange (ETDEWEB)

    Carlos, J. E. de; Granados, C. E.

    1972-07-01

    In 4{pi} {beta}-{gamma} coincidence measurements, precision on the evaluation of coincidence counting losses is made difficult because of complex overlapping effects between the{beta}--and {gamma}-side dead times due to pre cursive counted events. In this context the SAMAR electronic system is aimed to give a precise way of automatic counting and reduce the need for calculated corrections. This report describes its configuration and basic features. The SAMAR has been conceived in such a manner that both beta and gamma chains are sharing a common and non extending dead-time which is simultaneously applied to both channels. The shared dead time is made to be the only one inserted throughout the chains. Overlapping effects vanish and the three counting channels have identical transmission ratios. A new dead-time circuit based on fast linear gates as blocking elements has been developed. Application of the two-oscillator Muller's method evidences a fully non-extending character. Automatism is implemented by using a live timer corrective channel controlling the counting scalers. (Author) 21 refs.

  15. Methodology for estimation of 32P in bioassay samples by Cerenkov counting

    International Nuclear Information System (INIS)

    Wankhede, Sonal; Sawant, Pramilla D.; Yadav, R.K.B.; Rao, D.D.

    2016-01-01

    Radioactive phosphorus ( 32 P) as phosphate is used to effectively reduce bone pain in terminal cancer patients. Several hospitals in India carry out this palliative care procedure on a regular basis. Thus, production as well as synthesis of 32 P compounds has increased over the years to meet this requirement. Monitoring of radiation workers handling 32 P compounds is important for further strengthening of radiological protection program at processing facility. 32 P being a pure beta emitter (β max = 1.71 MeV, t 1/2 = 14.3 d), bioassay is the preferred individual monitoring technique. Method standardized at Bioassay Lab, Trombay, includes estimation of 32 P in urine by co-precipitation with ammonium phosphomolybdate (AMP) followed by gross beta counting. In the present study, feasibility of Cerenkov counting for detection of 32 P in bioassay samples was explored and the results obtained were compared with the gross beta counting technique

  16. Determination of total alpha and beta activities on vegetable samples by LSC

    International Nuclear Information System (INIS)

    Nogueira, Regina Apolinaria; Santos, Eliane Eugenia dos; Bakker, Alexandre Pereira; Vavassori, Giullia

    2011-01-01

    Gross alpha and beta analyses are screening techniques used for environmental radioactivity monitoring. The present study proposes to determine the gross alpha and beta activities in vegetable samples by using LSC - liquid scintillation spectrometry. The procedure was applied to vegetable foods. After ashing vegetable samples in a muffle furnace, 100 mg of ash were added to gel mixture of scintillation cocktails, Water - Instagel - Ultima Gold AB (6:10:4) ml, in polyethylene vial. Am-241 standard solution and a KCl (K-40) solution were used to determine the counting configuration, alpha/beta efficiencies and spillover

  17. Analysis of reactor-neutrino spectra fully based on gross theory of beta-decay emphasizing the special role of odd-odd FP nuclides

    Science.gov (United States)

    Yoshida, Tadashi; Tachibana, Takahiro; Chiba, Satoshi

    2017-09-01

    We applied the gross theory of β-decay to calculate the reactor antineutrino (νe) spectra emitted from 235,238U and 239,241Pu samples under neutron irradiation by summing up all the contributions from a large number of decaying fission-products (FPs). Considering the special role of the odd(Z)-odd(N) FPs in spectrum-shaping, we utilized the experimentally-known spin-parity of each odd-odd FP through the treatment proposed by Nakata, Tachibana and Yamada. Owing to this treatment, the consistency between calculated and experimental spectra was remarkably improved in a way expected from the nature of the gross theory of β-decay.

  18. Evaluation of gross radioactivity in foodstuffs

    International Nuclear Information System (INIS)

    Zorer, Oezlem Selcuk; Oeter, Cigdem

    2015-01-01

    The paper presents the results of radiological investigations of food products sampled in the summer and fall of 2011 and 2012 in different parts of Van, Turkey. Gross radioactivity measurements in food products were evaluated. Food items were divided into eight groups: (1) water, (2) fish, (3) cheese products, (4) fruits, (5) vegetables, (6) herbs, (7) walnut and (8) rock salt. The levels of the gross alpha and gross beta radioactivity in all food samples varied widely ranging from 0.070 to 10.885 Bq/g and from 0.132 to 48.285 Bq/g on dry mass basis, respectively. In one sample, gross alpha and gross beta activity concentrations were found to be relatively high according to the other samples and in all samples, the gross alpha radioactivity was measured lower than the gross beta radioactivity. The gross α and gross β activities were measured by using α/β counter of the multi-detector low background system (PIC MPC-9604).

  19. Evaluation of gross radioactivity in foodstuffs

    Energy Technology Data Exchange (ETDEWEB)

    Zorer, Oezlem Selcuk; Oeter, Cigdem [Yuzuncu Yil Univ., Van (Turkey). Dept. of Chemistry

    2015-05-15

    The paper presents the results of radiological investigations of food products sampled in the summer and fall of 2011 and 2012 in different parts of Van, Turkey. Gross radioactivity measurements in food products were evaluated. Food items were divided into eight groups: (1) water, (2) fish, (3) cheese products, (4) fruits, (5) vegetables, (6) herbs, (7) walnut and (8) rock salt. The levels of the gross alpha and gross beta radioactivity in all food samples varied widely ranging from 0.070 to 10.885 Bq/g and from 0.132 to 48.285 Bq/g on dry mass basis, respectively. In one sample, gross alpha and gross beta activity concentrations were found to be relatively high according to the other samples and in all samples, the gross alpha radioactivity was measured lower than the gross beta radioactivity. The gross α and gross β activities were measured by using α/β counter of the multi-detector low background system (PIC MPC-9604).

  20. An advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1984-01-01

    An improved computer-controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high-speed matrix printer and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  1. Advanced computer-controlled automatic alpha-beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.; Bruinekool, D.J.; Stapleton, E.E.

    1983-01-01

    An improved computer controlled automatic alpha-beta air sample counter was developed, based upon an earlier automatic air sample counter design. The system consists of an automatic sample changer, an electronic counting system utilizing a large silicon diode detector, a small desk-type microcomputer, a high speed matrix printer, and the necessary data interfaces. The system is operated by commands from the keyboard and programs stored on magnetic tape cassettes. The programs provide for background counting, Chi 2 test, radon subtraction, and sample counting for sample periods of one day to one week. Output data are printed by the matrix printer on standard multifold paper. The data output includes gross beta, gross alpha, and plutonium results. Data are automatically corrected for background, counter efficiency, and in the gross alpha and plutonium channels, for the presence of radon

  2. Determination of Li, B, and F by rapid instrumental neutron activation analysis using beta-particle counting

    International Nuclear Information System (INIS)

    Schmidt, J.O.; Palgaard, L.; Gwozdz, R.; Belhage, L.O.

    1984-01-01

    For the simultaneous determination of Li, B, and F, the application of rapid instrument neutron activation analysis was studied using 1.5s of irradiation and β-particle counting of 8 Li, 12 B, and 20 F. The fast transfer facility, Mach-1, the counting equipment, a 4-channel multiplexer, and a time-base controller are discussed. Further, the technique of simultaneous decay curve analysis of three successive decays is presented and quality control by residual analysis is demonstrated. Finally, analytical results are presented of the NBS-environmental standards Coal-1632a and Coal-1635, and of three BCR-coals intended as references materials

  3. Liquid scintillation alpha counting and spectrometry and its application to bone and tissue samples

    International Nuclear Information System (INIS)

    McDowell, W.J.; Weiss, J.F.

    1976-01-01

    Three methods for determination of alpha-emitting nuclides using liquid scintillation counting are compared, and the pertinent literature is reviewed. Data showing the application of each method to the measurement of plutonium concentration in tissue and bone samples are presented. Counting with a commercial beta-liquid scintillation counter and an aqueous-phase-accepting scintillator is shown to be accurate only in cases where the alpha activity is high (several hundred counts/min or more), only gross alpha counting is desired, and beta-gamma emitters are known to be absent from the sample or present at low levels compared with the alpha activity. Counting with the same equipment and an aqueous immiscible scintillator containing an extractant for the nuclide of interest (extractive scintillator) is shown to allow better control of alpha peak shift due to quenching, a significant reduction of beta-gamma interference, and, usually, a low background. The desirability of using a multichannel pulse-height analyzer in the above two counting methods is stressed. The use of equipment and procedures designed for alpha liquid scintillation counting is shown to allow alpha spectrometry with an energy resolution capability of 200 to 300 keV full-peak-width-at-half-peak-height and a background of 0.3 to 1.0 counts/min, or as low as 0.01 counts/min if pulse-shape discrimination methods are used. Methods for preparing animal bone and tissue samples for assay are described

  4. Scintillation counting apparatus

    International Nuclear Information System (INIS)

    Noakes, J.E.

    1978-01-01

    Apparatus is described for the accurate measurement of radiation by means of scintillation counters and in particular for the liquid scintillation counting of both soft beta radiation and gamma radiation. Full constructional and operating details are given. (UK)

  5. NM Gross Receipts Baseline

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  6. Gross National Happiness

    DEFF Research Database (Denmark)

    Giri, Krishna Prasad; Kjær-Rasmussen, Lone Krogh

    This paper investigates practices related to the ideology of infusing Gross National Happiness (GNH) into school curriculum, the effectiveness of the meditation and mind training and the implication of GNH for school environment. It also explores how GNH ambience has been managed and practiced...... of Gross National Happiness and Educating for Gross National happiness....

  7. {sup 90}Sr in human excretion samples. Comparison of MC-ICP-MS and conventional low-level beta-counting; {sup 90}Sr in menschlichen Ausscheidungsproben. Vergleich zwischen MC-ICP-MS und konventioneller Low Level Beta-Messung

    Energy Technology Data Exchange (ETDEWEB)

    Burow, M.; Schumacher, C.; Zoriy, M. [Forschungszentrum Juelich GmbH (Germany). Geschaeftsbereich fuer Sicherheit und Strahlenschutz

    2016-07-01

    At the present for determination of {sup 90}Sr in different human excretion samples manly radiochemical methods are applied, for example LL-beta- counter or liquid scintillation method. These methods require an isolation of strontium from other interfering radioactive species such as e.g. lead, polonium, plutonium, neptunium and potassium (for example, separation on Sr Resin, Fa. Eichrom, France) and afterwards long counting time restrict the usage in some application fields. On the other hand, the liquid scintillation techniques that may be used for detection present a challenge in the analysis of {sup 90}Sr in the presence of {sup 90}Y. However spectra of both radionuclides overlap in a certain zone and this may be resolved by mathematical calculations of {sup 90}Y ingrowth or by simply waiting for radiochemical equilibrium to be reached (2-3 weeks). In the case of emergency, monitoring of operating personal or civil population for possible incorporation of {sup 90}Sr via excretion samples a readily available, faster and reliable analytical procedure may prove to be of great importance. For these purposes, an analytical method for the determination of {sup 90}Sr in urine with high-sensitive MC-ICP-MS was developed in the radiochemical laboratory of the Department for Safety and Radiation Protection. The method was optimized to avoid a multitude of isobaric interferences that occur on m/z 90 using a cold-plasma operation condition of ICP-MS. The reported LOD as low as 0,3-1 Bq/l in the water samples was found to be acceptable for majority of our analytical tasks.

  8. Gross Sales Tax Collections

    Data.gov (United States)

    City of Jackson, Mississippi — This data is captured directly from the MS Department of Revenue and specific to the City of Jackson. It is compiled from Gross Sales Tax reported by taxpayers each...

  9. Loovkirjutamist õpetab Philip Gross

    Index Scriptorium Estoniae

    2011-01-01

    T.S. Elioti luulepreemia laureaat Philip Gross on Tallinna Ülikooli talvekooli rahvusvahelise kursuse "Poetry: A Conversation between Words and Silence" läbiviija. Oma seminarides keskendub ta lisaks loovkirjutamisele ka loova lugemise vajadusele

  10. Development of methodology for detection of long lived alpha emitters in air based on simultaneous alpha and beta activity measurement

    International Nuclear Information System (INIS)

    Kaushik, Vivek; Rath, D.P.; Vinayagami, Bhakti; Ashokkumar, P.; Umashankar, C.; Gopalakrishnan, R.K.; Kulkarni, M.S.

    2018-01-01

    Interference of the radon and thoron progeny co-deposited on the filtration media is the long-standing problem related to prompt analyses in continuous air sampling or monitoring of any potential suspect radionuclides. The solutions to this problem have been quite diverse, and included, for example, simple gross-alpha counting, the use of beta-to-alpha ratios, and the use of alpha spectrum analyses. The techniques based on beta to alpha disintegration ratios make use of the naturally occurring alpha to beta disintegration ratios and departures therefrom. This ratio is found empirically to be relatively constant. With the help of the solution of differential equation, which govern the deposition of radionuclide on filter paper, one can easily estimate theoretically the behavior of the radon progeny alpha to beta disintegration (or count) rate ratio

  11. RBC count

    Science.gov (United States)

    ... by kidney disease) RBC destruction ( hemolysis ) due to transfusion, blood vessel injury, or other cause Leukemia Malnutrition Bone ... slight risk any time the skin is broken) Alternative Names Erythrocyte count; Red blood cell count; Anemia - RBC count Images Blood test ...

  12. Low-Level {beta} and {gamma} Counting in the Region 0-10 Disintegrations Per Minute; Comptage {beta} et {gamma} d'echantillons de faible activite (0 a 10 desintegrations par minute); Izmerenie {beta}- i {gamma}-izlucheniya maloj moshchnosti (0-10 raspadov v minutu); Recuento {beta} y {gamma} de muestras de baja actividad (0 a 10 desintegraciones por minuto)

    Energy Technology Data Exchange (ETDEWEB)

    Manov, George G [Tracerlab Inc. (United States)

    1960-06-15

    Measurements of levels of radioactivity in the region of 0-1.0 disintegrations per minute are becoming increasingly useful in the standardization of radionuclides as well as in other branches of science such as geology and medicine. For example, there is frequent need for low-level counting in the field of biological and tracer applications, particularly, in those cases in which the use of a higher level of radiation would alter the course of the mechanism or process under study. Frequently such measurements must be made under conditions in which the sample possesses an activity of only 1% of the normal, unshielded background radiation. At other times, an additional requirement is imposed because the radionuclide may have a very short half-life. There are three general ways in which the reliability of low-level measurements can be increased: more efficient counters, smaller background corrections and more stable, noise-free electronic systems. In this paper, comparative tests are described of the relative merits of hree different types of guard (anti-coincidence) counters in reducing the background. Measurements were made of: (a) umbrella, (b) annular, and (c) scintillating plastic igloo. The increasing difficulty of obtaining activity-free materials for construction of counters is a matter of some concern. Data are presented for the range of activities of materials available commercially. Stockpiling of such materials, preferably of pre-War II origin is rapidly becoming a necessity. The stability of the electronic system is a prime requisite for low level counting, particularly to avoid the counting of spurious pulses. A system is described in which a slow, measured rate of pulses is fed into the electronics, passed through the amplifier and deducted from the gross output of the register. In general, transistorized circuitry including pre-amplifiers and power supplies are more satisfactory than conventional vacuum tube devices. (author) [French] La mesure des

  13. Determination of self absorption correction factor (SAF) for gross alpha measurement in water samples by BIS method

    International Nuclear Information System (INIS)

    Raveendran, Nanda; Baburajan, A.; Ravi, P.M.

    2018-01-01

    The laboratories accredited by AERB undertake the measurement of gross alpha and gross beta in packaged drinking water from manufactures across the country and analyze as per the procedure of Bureau of Indian standards. The accurate measurements of gross alpha in the drinking water sample is a challenge due to the self absorption of alpha particle from varying precipitate (Fe(OH) 3 +BaSO 4 ) thickness and total dissolved solids (TDS). This paper deals with a study on tracer recovery generation and self absorption correction factor (SAF). ESL, Tarapur has participated in an inter-laboratory comparison exercise conducted by IDS, RSSD, BARC as per the recommendation of AERB for the accredited laboratories. The thickness of the precipitate is an important aspect which affected the counting process. The activity was reported after conducting multiple experiments with uranium tracer recovery and precipitate thickness. Later on to make our efforts simplified, an average tracer recovery and Self Absorption correction Factor (SAF) was derived by the present experiment and the same was used for the re-calculation of activity from the count rate reported earlier

  14. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques

    International Nuclear Information System (INIS)

    Sierra, I.; Delgado, A.; Navarro, T.; Macias, M. T.

    2007-01-01

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs

  15. Counting carbohydrates

    Science.gov (United States)

    Carb counting; Carbohydrate-controlled diet; Diabetic diet; Diabetes-counting carbohydrates ... Many foods contain carbohydrates (carbs), including: Fruit and fruit juice Cereal, bread, pasta, and rice Milk and milk products, soy milk Beans, legumes, ...

  16. Radon Daughters Background Reduction in Alpha Particles Counting System

    International Nuclear Information System (INIS)

    Dadon, S. S.; Pelled, O.; Orion, I.

    2014-01-01

    The ABPC method is using a serially occurring events of the beta decay of the 214Bi fallow by alpha decay of the 214Po that take place almost simultaneously to detect the Pseudo Coincidence Event (PCE) from the RDP, and to subtract them from the gross alpha counts. 267 This work showed that it is possible to improve the efficiency of RDP background reduction, including subtracting the 218Po contribution by using the ABPC method based on a single solid state silicon PIPS detector. False counts percentage obtained at the output of the PCE circuit were smaller than 0.1%. The results show that the PCE circuit was not influenced by non RDP alpha emitters. The PCE system did not reduce the non PCE of the 218Po. After 20 minutes the 218Po was strongly decayed, and its contribution became negligible. In order to overcome this disadvantage, a mathematical matching calculations for the 214Po and the 218Po decay equations were employed, and a constant ratio of the APo214(0) / APo218(0) was obtained. This ratio can be used to estimate the count rate of the 218Po at the first 20 minutes, and to subtract it from the total count rate in order to obtain correct RDP reduction

  17. Particle count monitoring of reverse osmosis water treatment for removal of low-level radionuclides

    International Nuclear Information System (INIS)

    Moritz, E.J.; Hoffman, C.R.; Hergert, T.R.

    1995-01-01

    Laser diode particle counting technology and analytical measurements were used to evaluate a pilot-scale reverse osmosis (RO) water treatment system for removal of particulate matter and sub-picocurie low-level radionuclides. Stormwater mixed with Waste Water Treatment Plant (WWTP) effluent from the Rocky Flats Environmental Technology Site (RFETS), formerly a Department of Energy (DOE) nuclear weapons production facility, were treated. No chemical pretreatment of the water was utilized during this study. The treatment system was staged as follows: multimedia filtration, granular activated carbon adsorption, hollow tube ultrafiltration, and reverse osmosis membrane filtration. Various recovery rates and two RO membrane models were tested. Analytical measurements included total suspended solids (TSS), total dissolved solids (TDS), gross alpha (α) and gross beta (β) activity, uranium isotopes 233/234 U and 238 U, plutonium 239/240 Pu, and americium 241 Am. Particle measurement between 1--150 microns (μ) included differential particle counts (DPC), and total particle counts (TPC) before and after treatment at various sampling points throughout the test. Performance testing showed this treatment system produced a high quality effluent in clarity and purity. Compared to raw water levels, TSS was reduced to below detection of 5 milligrams per liter (mg/L) and TDS reduced by 98%. Gross α was essentially removed 100%, and gross β was reduced an average of 94%. Uranium activity was reduced by 99%. TPC between 1-150μ were reduced by an average 99.8% to less than 1,000 counts per milliliter (mL), similar in purity to a good drinking water treatment plant. Raw water levels of 239/240 Pu and 241 Am were below reliable quantitation limits and thus no removal efficiencies could be determined for these species

  18. Effects of somatic cell count on the gross composition, protein ...

    African Journals Online (AJOL)

    and >265,000 cells/ml) on ewe milk composition, protein fractions and ... 6.38, true protein, true whey protein, fat, lactose, dry matter, ash, phosphorus, ... management practices, and representative of the typical ewe herd .... pasteurised before being analysed. .... Mastitis detection: current trends and future perspectives.

  19. Beta emitter radionuclides (90Sr contamination in animal feed: validation and application of a radiochemical method by ultra low level liquid scintillation counting

    Directory of Open Access Journals (Sweden)

    Marco Iammarino

    2015-02-01

    Full Text Available 90Sr is considered as a dangerous contaminant of agri-food supply chains due to its chemical affinity with Calcium, which makes its absorption in bones easy. 90Sr accumulation in raw materials and then in final products is particularly significant in relationship to its ability to transfer into animal source products. The radionuclides transfer (137Cs and 90Sr from environment to forages and then to products of animal origin (milk, cow and pork meats was studied and evaluated in different studies, which were carried out in contaminated areas, from Chernobyl disaster until today. In the present work, the development and validation of a radiochemical method for the detection of 90Sr in different types of animal feed, and the application of this technique for routinely control activities, are presented. Liquid scintillation counting was the employed analytical technique, since it is able to determine very low activity concentrations of 90Sr (<0.01 Bq kg–1. All samples analysed showed a 90Sr contamination much higher than method detection limit (0.008 Bq kg–1. In particular, the highest mean activity concentration was registered in hay samples (2.93 Bq kg–1, followed by silage samples (2.07 Bq kg–1 and animal feeds (0.77 Bq kg–1. In fact, all samples were characterized by 90Sr activity concentrations much lower than reference limits. This notwithstanding, the necessity to monitor these levels was confirmed, especially considering that 90Sr is a possible carcinogen for human.

  20. Development of krypton-85 measurement in ocean samples by beta counting and use of the krypton-85 as a tracer in oceanography

    International Nuclear Information System (INIS)

    Ternon, Jean-Francois

    1990-01-01

    Krypton-85 present in the environment has essentially an anthropogenic origin, and the knowledge of the evolution of its concentration in the atmosphere, and of its mode of penetration in the ocean by gaseous exchange at the surface, and its bio-geochemical stability in the environment make it a potential tool to trace movements of water masses in the ocean. This research thesis aims at being a contribution to the implementation of an experimental device which would allow very low concentrations of krypton-85 in the ocean to be measured. After a presentation of the general context, the author reports the development of the two last steps of krypton-85 measurement: the separation of krypton by gas chromatography, and the measurement of krypton-85 by low-level radioactive counting. Then, the author reports the study of the use of krypton-85 as a tracer in oceanography, and notably highlights its similarities with CFC which are widely used to study ocean circulation [fr

  1. Low-level measurements by liquid scintillation counting

    International Nuclear Information System (INIS)

    Schoenhofer, F.

    1991-01-01

    Liquid scintillation counting has become a convenient tool for analysis of many beta- and alpha-emitters even in ultra low-level concentration ranges. Extremely low background is achieved in a commercially available counter by an active shielding and heavy lead shielding. Thus special time saving radiochemical separation processes could be designed. Extremely simple sample preparation techniques can be used. Counting time can be reduced and sample throughput enhanced. Also precision can be enhanced. From the author's research, several applications are discussed. They include: tritium in water without enrichment, tritium in urine (excretion analysis), carbon-14 in samples like alcohol or vinegar, Rn-222 in water and air, even gaseous Kr-85. A simple and fast method for Sr-90 in environmental samples and food has been developed and the Ra-226-concentration in water can be measured as low as 30 mBq/l without any chemical separation or enrichment. The instrument has been used successfully for screening purposes after the Chernobyl accident as well as for monitoring groundwater after a large scale contamination in Lower Austria. Using a 'gross-beta-measurement' effluents from a nuclear installation are monitored, clearly showing advantages over traditional methods. α-β-discrimination reduces the background for alpha emitters to practically zero. Examples from the determination of Ra-226 in water are shown

  2. Gross decontamination experiment report

    International Nuclear Information System (INIS)

    Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment

  3. Gross xenon stability

    International Nuclear Information System (INIS)

    Lewins, J.D.; Wilson, P.P.H.

    1997-01-01

    The effect of xenon in thermal reactors on steady operation is generally destabilizing. Illustrating this involves the study of appropriate transfer functions, which may be conveniently displayed in three ways: as Bode, Nyquist, and root-locus diagrams. The three forms allow different aspects to be highlighted. These are illustrated for the effect of xenon with allowance not only for the stabilizing effect of the direct yield in fission but also to show the consequences of neglecting the time dependence due to the thermal capacity of the reactor. With careful interpretation, all these forms give an interpretation of stability that is consistent with direct evaluation and promote the understanding of the onset of gross oscillations in power

  4. Gross decontamination experiment report

    Energy Technology Data Exchange (ETDEWEB)

    Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.

    1983-07-01

    A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.

  5. Counting cormorants

    DEFF Research Database (Denmark)

    Bregnballe, Thomas; Carss, David N; Lorentsen, Svein-Håkon

    2013-01-01

    This chapter focuses on Cormorant population counts for both summer (i.e. breeding) and winter (i.e. migration, winter roosts) seasons. It also explains differences in the data collected from undertaking ‘day’ versus ‘roost’ counts, gives some definitions of the term ‘numbers’, and presents two...

  6. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  7. Radioisotope indicator, type BETA 2

    International Nuclear Information System (INIS)

    Duszanski, M.; Pankow, A.; Skwarczynski, B.

    1975-01-01

    The authors describe a radioisotope indicator, type BETA 2, constructed in the ZKMPW Works to be employed in mines for counting, checking, signalling the presence and positioning of cars, as well as monitoring the state of some other equipment. (author)

  8. BETA digital beta radiometer

    International Nuclear Information System (INIS)

    Borovikov, N.V.; Kosinov, G.A.; Fedorov, Yu.N.

    1989-01-01

    Portable transportable digital beta radiometer providing for measuring beta-decay radionuclide specific activity in the range from 5x10 -9 up to 10 -6 Cu/kg (Cu/l) with error of ±25% is designed and introduced into commercial production for determination of volume and specific water and food radioactivity. The device specifications are given. Experience in the BETA radiometer application under conditions of the Chernobyl' NPP 30-km zone has shown that it is convenient for measuring specific activity of the order of 10 -8 Cu/kg, and application of a set of different beta detectors gives an opportunity to use it for surface contamination measurement in wide range of the measured value

  9. Pricing, renegotiation and gross inequities

    Energy Technology Data Exchange (ETDEWEB)

    Kirkham, J.S. (Van Cott, Bagley, Cornwall McCarthy, Salt Lake City, UT (USA))

    1990-01-01

    Reviews pricing, renegotiation and gross inequity provisions of coal supply agreements in order to provide practical assistance to an attorney called upon to draft in written form the intent of buyer and seller. 26 refs.

  10. Technical Basis for the Use of Alpha Absorption Corrections on RCF Gross Alpha Data

    International Nuclear Information System (INIS)

    Ceffalo, G.M.

    1999-01-01

    This document provides the supporting data and rationale for making absorption corrections to gross alpha data to correct alpha data for loss due to absorption in the sample matrix. For some time there has been concern that the gross alpha data produced by the Environmental Restoration Contractor Radiological Counting Facility, particularly gross alpha analysis on soils, has been biased toward low results, as no correction for self-absorption was applied to the counting data. The process was investigated, and a new methodology for alpha self-absorption has been developed

  11. Counting probe

    International Nuclear Information System (INIS)

    Matsumoto, Haruya; Kaya, Nobuyuki; Yuasa, Kazuhiro; Hayashi, Tomoaki

    1976-01-01

    Electron counting method has been devised and experimented for the purpose of measuring electron temperature and density, the most fundamental quantities to represent plasma conditions. Electron counting is a method to count the electrons in plasma directly by equipping a probe with the secondary electron multiplier. It has three advantages of adjustable sensitivity, high sensitivity of the secondary electron multiplier, and directional property. Sensitivity adjustment is performed by changing the size of collecting hole (pin hole) on the incident front of the multiplier. The probe is usable as a direct reading thermometer of electron temperature because it requires to collect very small amount of electrons, thus it doesn't disturb the surrounding plasma, and the narrow sweep width of the probe voltage is enough. Therefore it can measure anisotropy more sensitively than a Langmuir probe, and it can be used for very low density plasma. Though many problems remain on anisotropy, computer simulation has been carried out. Also it is planned to provide a Helmholtz coil in the vacuum chamber to eliminate the effect of earth magnetic field. In practical experiments, the measurement with a Langmuir probe and an emission probe mounted to the movable structure, the comparison with the results obtained in reverse magnetic field by using a Helmholtz coil, and the measurement of ionic sound wave are scheduled. (Wakatsuki, Y.)

  12. Determination of beta and gamma radioactivity on the coal

    International Nuclear Information System (INIS)

    Suhardi; Mulyono; Sutanto WW; Rosidi

    2013-01-01

    Radioactivity in coal, botton ash and fly ash. This determination was carried out to know each the radioactivity of β gross, γ gross on the coal, botton ash and fly ash, which accommodation of environment data the present in PLTU Paiton Probolinggo. Samples taken preparation and analysis based on the procedures of environmental radioactivity analysis. The radioactivity on the PLTU Paiton Probolinggo detected by beta gross Spectrometer with Geiger Muller (GM) and gamma Spectrometer with Ge(Li) detector. The result indicates that radioactivity concentration of beta and gamma gross are (95,57-308,26) Bq/kg and (1,374 - 31,677) Bq/kg respectively. (author)

  13. Fixation of radioactive elements on diethylene-glycol-succinate and its use for the determination of gross activity in urine

    International Nuclear Information System (INIS)

    Hafez, M.B.; Nazmy, A.F.; Eldesoky, M.M.

    1977-01-01

    Studies are given to illustrate surface adsorption of 144 Ce, 90 Sr, 232 Th, 235 U, 239 Pu and 241 Am on diethylene-glycol-succinate, DGS. Adsorption of these elements was studied from aqueous and phosphate solutions. A procedure for the determination of gross activity in urine, based on surface adsorption on DGS is described. Groups of nine solutions, in 30 ml 1N HNO 3 , were spiked with the investigated radioactive elements (approximately 5 pCi). The pH of the solutions was adjusted to a range of 0.5 to 10 using ammonia. Each solution was passed through the column and the fixed activity was removed from the column with 50 ml of 4N HCl, followed by two washes with 10 ml of distilled water. The acid solution was evaporated to dryness for alpha- or beta-counting. The percentage fixation was determined by comparison with a standard source of the same spiked element. Adsorption was found to depend on pH, age of the tracer solution, hydrolysis state of the radioelement and the ionic strength of the solution. The adsorption phenomenon which was particularly well observed could be used as a separation stage in a method for the determination of gross activity in urine. Recoveries of about 85% were obtained. (T.G.)

  14. Counting Possibilia

    Directory of Open Access Journals (Sweden)

    Alfredo Tomasetta

    2010-06-01

    Full Text Available Timothy Williamson supports the thesis that every possible entity necessarily exists and so he needs to explain how a possible son of Wittgenstein’s, for example, exists in our world:he exists as a merely possible object (MPO, a pure locus of potential. Williamson presents a short argument for the existence of MPOs: how many knives can be made by fitting together two blades and two handles? Four: at the most two are concrete objects, the others being merely possible knives and merely possible objects. This paper defends the idea that one can avoid reference and ontological commitment to MPOs. My proposal is that MPOs can be dispensed with by using the notion of rules of knife-making. I first present a solution according to which we count lists of instructions - selected by the rules - describing physical combinations between components. This account, however, has its own difficulties and I eventually suggest that one can find a way out by admitting possible worlds, entities which are more commonly accepted - at least by philosophers - than MPOs. I maintain that, in answering Williamson’s questions, we count classes of physically possible worlds in which the same instance of a general rule is applied.

  15. Quantum Gross-Pitaevskii Equation

    Directory of Open Access Journals (Sweden)

    Jutho Haegeman, Damian Draxler, Vid Stojevic, J. Ignacio Cirac, Tobias J. Osborne, Frank Verstraete

    2017-07-01

    Full Text Available We introduce a non-commutative generalization of the Gross-Pitaevskii equation for one-dimensional quantum gasses and quantum liquids. This generalization is obtained by applying the time-dependent variational principle to the variational manifold of continuous matrix product states. This allows for a full quantum description of many body system ---including entanglement and correlations--- and thus extends significantly beyond the usual mean-field description of the Gross-Pitaevskii equation, which is known to fail for (quasi one-dimensional systems. By linearizing around a stationary solution, we furthermore derive an associated generalization of the Bogoliubov -- de Gennes equations. This framework is applied to compute the steady state response amplitude to a periodic perturbation of the potential.

  16. Categorical counting.

    Science.gov (United States)

    Fetterman, J Gregor; Killeen, P Richard

    2010-09-01

    Pigeons pecked on three keys, responses to one of which could be reinforced after a few pecks, to a second key after a somewhat larger number of pecks, and to a third key after the maximum pecking requirement. The values of the pecking requirements and the proportion of trials ending with reinforcement were varied. Transits among the keys were an orderly function of peck number, and showed approximately proportional changes with changes in the pecking requirements, consistent with Weber's law. Standard deviations of the switch points between successive keys increased more slowly within a condition than across conditions. Changes in reinforcement probability produced changes in the location of the psychometric functions that were consistent with models of timing. Analyses of the number of pecks emitted and the duration of the pecking sequences demonstrated that peck number was the primary determinant of choice, but that passage of time also played some role. We capture the basic results with a standard model of counting, which we qualify to account for the secondary experiments. Copyright 2010 Elsevier B.V. All rights reserved.

  17. [Corrected count].

    Science.gov (United States)

    1991-11-27

    The data of the 1991 census indicated that the population count of Brazil fell short of a former estimate by 3 million people. The population reached 150 million people with an annual increase of 2%, while projections in the previous decade expected an increase of 2.48% to 153 million people. This reduction indicates more widespread use of family planning (FP) and control of fertility among families of lower social status as more information is being provided to them. However, the Ministry of Health ordered an investigation of foreign family planning organizations because it was suspected that women were forced to undergo tubal ligation during vaccination campaigns. A strange alliance of left wing politicians and the Roman Catholic Church alleges a conspiracy of international FP organizations receiving foreign funds. The FP strategies of Bemfam and Pro-Pater offer women who have little alternative the opportunity to undergo tubal ligation or to receive oral contraceptives to control fertility. The ongoing government program of distributing booklets on FP is feeble and is not backed up by an education campaign. Charges of foreign interference are leveled while the government hypocritically ignores the grave problem of 4 million abortions a year. The population is expected to continue to grow until the year 2040 and then to stabilize at a low growth rate of .4%. In 1980, the number of children per woman was 4.4 whereas the 1991 census figures indicate this has dropped to 3.5. The excess population is associated with poverty and a forsaken caste in the interior. The population actually has decreased in the interior and in cities with 15,000 people. The phenomenon of the drop of fertility associated with rural exodus is contrasted with cities and villages where the population is 20% less than expected.

  18. NM Gross Receipts January - June 2012

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  19. NM Gross Receipts July - December 2013

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  20. NM Gross Receipts January - June 2014

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  1. NM Gross Receipts July - December 2012

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  2. NM Gross Receipts January - June 2013

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  3. NM Gross Receipts January - June 2011

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This layer represents boundaries for New Mexico's gross receipts tax districts as identified on the "Gross Receipts Tax Rate Schedule" published by the Taxation and...

  4. Speculative Betas

    OpenAIRE

    Harrison Hong; David Sraer

    2012-01-01

    We provide a model for why high beta assets are more prone to speculative overpricing than low beta ones. When investors disagree about the common factor of cash-flows, high beta assets are more sensitive to this macro-disagreement and experience a greater divergence-of-opinion about their payoffs. Short-sales constraints for some investors such as retail mutual funds result in high beta assets being over-priced. When aggregate disagreement is low, expected return increases with beta due to r...

  5. Determination of radon daughter activities of different aerosol fractions by gross-α and gross-β measurements

    International Nuclear Information System (INIS)

    Katona, T.; Kanyar, B.; Jobbagy, V.; Kavasi, N.; Molnar, A.; Imre, K.

    2004-01-01

    The aim was to determine the radioactivities of the radon progenies ( 218 Po, 214 Pb, 214 Bi and 214 Po) attached to the carrier aerosol particles with respect to the size distribution in order to improve the assessment of the inhalation dose. We derived the radionuclide-specific activity concentrations from gross alpha and gross beta measurements provided during 2 hours after sampling and model calculations including parameter estimation. For the aerosol sampling we used an electrical low pressure impactor, which is able to collect aerosol particles in 12 different diameter ranges. In our test investigations the aerosol particles were collected from a closed chamber in a common laboratory building. The chamber contained a relatively high radon concentration (60-90 kBq/m 3 ) in equilibrium with the short lived daughters generated previously without any additional aerosol sources. For the nuclear measurements of the aerosol samples ZnS/plastic sandwich detectors have been used. The time series data of gross alpha and gross beta activities were fitted simultaneously and the initial activities of the daughters were estimated. According to the results from two different fractions (0.06 and 0.7 μm) just followed the end of sampling they contain a higher 218 Po activity than the 214 Pb and 214 Bi ones. The preliminary assessments for the special air conditions show that the 214 Pb-to- 218 Po activity ratios are higher for the small aerosol particles than for the larger ones. The estimated errors of the initial activities were near to 50% in a large part of cases. (author)

  6. Evaluation of polymer-coated CsI:Tl as an alpha/beta pulse shape discriminating flow-cell

    International Nuclear Information System (INIS)

    Branton, S.D.; Fjeld, R.A.; DeVol, T.A.

    1996-01-01

    A pulse shape discriminating flow-cell radiation detection system constructed with polymer coated CsI:Tl was evaluated for simultaneous gross alpha/gross beta quantification. The CsI:TI scintillator was crushed and sieved to 63-90 μm particle size and microencapsulated with Parylene C to reduce its rate of dissolution. Averaged over the first hour of use, the pulse shape discrimination figure-of-merit was 1.4 and the detection efficiencies were 64.9 ± 5.7 %, 52.5 ± 4.5 % and 4.5 ± 0.2 % for 233 U, 90 Sr/ 90 Y and 14 C , respectively. The typical background count rate in the alpha and beta pulse shape window was 0.17 and 0.004 cps, respectively. The resultant minimum detectable activity for a 30 second count time was calculated to be 0.19 ± 0.01 Bq, 0.9 ± 0.1 Bq and 11.4 ± 0.6 Bq for 233 U, 90 Sr/ 90 Y and 14 C, respectively. Although the 3 μm thick microencapsulation reduced CsI:Tl dissolution, the detection efficiency declined by a factor of two after 4.8 hours while the pulse shape resolution degraded slightly

  7. Gross anatomy of network security

    Science.gov (United States)

    Siu, Thomas J.

    2002-01-01

    Information security involves many branches of effort, including information assurance, host level security, physical security, and network security. Computer network security methods and implementations are given a top-down description to permit a medically focused audience to anchor this information to their daily practice. The depth of detail of network functionality and security measures, like that of the study of human anatomy, can be highly involved. Presented at the level of major gross anatomical systems, this paper will focus on network backbone implementation and perimeter defenses, then diagnostic tools, and finally the user practices (the human element). Physical security measures, though significant, have been defined as beyond the scope of this presentation.

  8. Study of the radioactivity of drinking water in the city of Antsirabe using the method of liquid scintillation counting

    International Nuclear Information System (INIS)

    RAKOTOMANGA, H.

    2003-01-01

    The objective of this work is to determine the radioactivity by liquid scintillation counting (LSC) and to study the distribution of radionuclides in drinking water from the Antsirabe region. Optiphase Hisafe 3TM is used to measure gross alpha-beta radioactivity. Radium, radon and the excess of short half-life radionuclides are obtained from MaxilightTM cocktail. Results of measurement of drinking water samples show that : gross alpha-beta activities are between (120±27) Bq.l -1 and (426±47) Bq.l -1 , the radium activities are from (14±2)Bq.l -1 to (78±5) Bq.l -1 , radon activities are from (0.6±0.2)Bq.l -1 to (60±6) Bq.l -1 , short half-life radionuclides activities are between 25±8 Bq.l -1 and 270±27 Bq.l -1 .Annual dose exposure from ingestion of radium-226 is between (2.09 ± 0.32)mSv and (11.03 ± 0.73)mSv. These values are close to the Malagasy standard (5 mSv). The results show that drinking waters from the Antsirabe region contain natural radionuclides. Dose exposure increases if the water is directly ingested after collection. [fr

  9. Beta/alpha continuous air monitor

    Science.gov (United States)

    Becker, G.K.; Martz, D.E.

    1988-06-27

    A single deep layer silicon detector in combination with a microcomputer, recording both alpha and beta activity and the energy of each pulse, distinquishing energy peaks using a novel curve fitting technique to reduce the natural alpha counts in the energy region where plutonium and other transuranic alpha emitters are present, and using a novel algorithm to strip out radon daughter contribution to actual beta counts. 7 figs.

  10. A {beta} - {gamma} coincidence; Metodo de coincidencias {beta} - {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Agullo, F

    1960-07-01

    A {beta} - {gamma} coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from {sup 1}98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs.

  11. The Schroedinger functional for Gross-Neveu models

    International Nuclear Information System (INIS)

    Leder, B.

    2007-01-01

    Gross-Neveu type models with a finite number of fermion flavours are studied on a two-dimensional Euclidean space-time lattice. The models are asymptotically free and are invariant under a chiral symmetry. These similarities to QCD make them perfect benchmark systems for fermion actions used in large scale lattice QCD computations. The Schroedinger functional for the Gross-Neveu models is defined for both, Wilson and Ginsparg-Wilson fermions, and shown to be renormalisable in 1-loop lattice perturbation theory. In two dimensions four fermion interactions of the Gross-Neveu models have dimensionless coupling constants. The symmetry properties of the four fermion interaction terms and the relations among them are discussed. For Wilson fermions chiral symmetry is explicitly broken and additional terms must be included in the action. Chiral symmetry is restored up to cut-off effects by tuning the bare mass and one of the couplings. The critical mass and the symmetry restoring coupling are computed to second order in lattice perturbation theory. This result is used in the 1-loop computation of the renormalised couplings and the associated beta-functions. The renormalised couplings are defined in terms of suitable boundary-to-boundary correlation functions. In the computation the known first order coefficients of the beta-functions are reproduced. One of the couplings is found to have a vanishing betafunction. The calculation is repeated for the recently proposed Schroedinger functional with exact chiral symmetry, i.e. Ginsparg-Wilson fermions. The renormalisation pattern is found to be the same as in the Wilson case. Using the regularisation dependent finite part of the renormalised couplings, the ratio of the Lambda-parameters is computed. (orig.)

  12. Validating the Rett Syndrome Gross Motor Scale

    DEFF Research Database (Denmark)

    Downs, Jenny; Stahlhut, Michelle; Wong, Kingsley

    2016-01-01

    .93-0.98). The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice......Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated...... the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age...

  13. Screening procedures for alpha, beta and gamma emitting radionuclides in urine

    International Nuclear Information System (INIS)

    Kramer, G.H.; Gardner, S.E.; Johnson, J.R.

    1983-08-01

    The gross actinide and beta screening methods currently used by the Bioassay Laboratory at Chalk River Nuclear Laboratories have been documented and tested. The gross gamma method has also been documented. The gross actinide method was tested with Th-nat, Pu-239, Np-237, Am-241 and Cm-244 and the average percent recoveries were 90, 99, 45, 72 and 78, respectively. The gross beta method was tested with Sr-90/Y-90, Ce-144/Pr-144, Pm-147 and Ba-133 and the average percent recoveries were 78, 100, 46 and 46, respectively. Detection limits for the gross actinide (alpha) method are found to be about 0.4 mBq and about 39 mBq for the gross beta method

  14. Alpha/beta separation in liquid scintillation gel samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1994-01-01

    The pulse shape analysis commonly used in liquid scintillation alpha/beta separations is satisfactory for moderate quench levels. However, for gel samples, the alpha particle counting efficiency is never greater than 10%, and an optimum separation of the alpha component cannot be achieved when beta to alpha counting rate ratios are greater than 100. In such cases, it is better to use a spectrum analysis method for alpha/beta separation. ((orig.))

  15. Measures of Gross National Happiness

    Directory of Open Access Journals (Sweden)

    Ruut Veenhoven

    2010-02-01

    Full Text Available Happiness is rising on the political agenda and this calls for measures of how well nations perform in creating great happiness for a great number, analogous to measures of success in creating wealth, such as GDP. Happiness is defined as subjective enjoyment of one’s life as-a-whole and this can be measured using self-reports. Question on happiness are currently used in large scale surveys of the general population in nations. As a result we have now comparable data on happiness in 144 contemporary nations and time-series of 25 years and longer on 11 developed nations. These data can be aggregated in different ways: If the aim is simply greater happiness for a greater number of citizens, Average happiness (AH is an appropriate measure. If the focus is on enduring happiness, it is better to combine average happiness with longevity in an index of Happy Life Years (HLY. If the aim is to reduce disparity among citizens a relevant indicator is the Inequality of Happiness (IH in the nations as measured with the standard deviation. Average and dispersion can also be combined in an index of Inequality-Adjusted Happiness (IAH. Comparison across nations shows sizable differences on all these measures of gross national happiness and these differences correspond with societal characteristics that can be influenced by policy makers, such as freedom and justice. Comparison over time shows major improvement during the last decade.

  16. Beta spectrometry

    International Nuclear Information System (INIS)

    Dryak, P.; Zderadicka, J.; Plch, J.; Kokta, L.; Novotna, P.

    1977-01-01

    For the purpose of beta spectrometry, a semiconductor spectrometer with one Si(Li) detector cooled with liquid nitrogen was designed. Geometrical detection efficiency is about 10% 4 sr. The achieved resolution for 624 keV conversion electrons of sup(137m)Ba is 2.6 keV (FWHM). A program was written in the FORTRAN language for the correction of the deformation of the measured spectra by backscattering in the analysis of continuous beta spectra. The method permits the determination of the maximum energy of the beta spectrum with an accuracy of +-5 keV. (author)

  17. Heterogeneous counting on filter support media

    International Nuclear Information System (INIS)

    Long, E.; Kohler, V.; Kelly, M.J.

    1976-01-01

    Many investigators in the biomedical research area have used filter paper as the support for radioactive samples. This means that a heterogeneous counting of sample sometimes results. The count rate of a sample on a filter will be affected by positioning, degree of dryness, sample application procedure, the type of filter, and the type of cocktail used. Positioning of the filter (up or down) in the counting vial can cause a variation of 35% or more when counting tritiated samples on filter paper. Samples of varying degrees of dryness when added to the counting cocktail can cause nonreproducible counts if handled improperly. Count rates starting at 2400 CPM initially can become 10,000 CPM in 24 hours for 3 H-DNA (deoxyribonucleic acid) samples dried on standard cellulose acetate membrane filters. Data on cellulose nitrate filters show a similar trend. Sample application procedures in which the sample is applied to the filter in a small spot or on a large amount of the surface area can cause nonreproducible or very low counting rates. A tritiated DNA sample, when applied topically, gives a count rate of 4,000 CPM. When the sample is spread over the whole filter, 13,400 CPM are obtained with a much better coefficient of variation (5% versus 20%). Adding protein carrier (bovine serum albumin-BSA) to the sample to trap more of the tritiated DNA on the filter during the filtration process causes a serious beta absorption problem. Count rates which are one-fourth the count rate applied to the filter are obtained on calibrated runs. Many of the problems encountered can be alleviated by a proper choice of filter and the use of a liquid scintillation cocktail which dissolves the filter. Filter-Solv has been used to dissolve cellulose nitrate filters and filters which are a combination of cellulose nitrate and cellulose acetate. Count rates obtained for these dissolved samples are very reproducible and highly efficient

  18. Alternative Measure of Wellbeing: Bhutan's Gross National ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    There is growing demand for innovative yet rigorous measures of national wellbeing beyond gross domestic product. In 2008, the Centre for Bhutan Studies - Bhutan's main policy research centre - posted data from a preliminary survey of the country's Gross National Happiness (GNH). The Centre for Bhutan Studies ...

  19. Beta Blockers

    Science.gov (United States)

    ... may not work as effectively for people of African heritage and older people, especially when taken without ... conditions/high-blood-pressure/in-depth/beta-blockers/ART-20044522 . Mayo Clinic Footer Legal Conditions and Terms ...

  20. Determination of 210Pb by direct gamma-ray spectrometry, beta counting via 210Bi and alpha-particle spectrometry via 210Po in coal, slag and ash samples from thermal power plant

    International Nuclear Information System (INIS)

    Seslak, Bojan; Vukanac, Ivana; Kandic, Aleksandar; Durasevic, Mirjana; Eric, Milic; Jevremovic, Aleksandar

    2017-01-01

    In order to compare three different techniques and estimate radiological impact, activity concentration of 210 Pb in coal, slag and ash samples from thermal power plant 'Nikola Tesla', Serbia, were measured, and results are presented in this study. Determination of 210 Pb was carried out in three ways: using HPGe gamma spectrometer and via in-growth of 210 Po and 210 Bi by alpha-particle spectrometry and proportional counting, respectively. The results obtained for three different techniques were compared. Statistical analysis and comparison of methods were carried out by combination of Z score and χ 2 statistical tests. Tests results, as well as values of measured activities concentrations obtained by alpha and gamma spectrometry, showed that gamma spectrometry is a valid alternative to time-consuming alpha spectrometry for low level activity measurements of 210 Pb. This remark is also valid even for gamma spectrometers with poor efficiency in low energy region. (author)

  1. Determining random counts in liquid scintillation counting

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1979-01-01

    During measurements involving coincidence counting techniques, errors can arise due to the detection of chance or random coincidences in the multiple detectors used. A method and the electronic circuits necessary are here described for eliminating this source of error in liquid scintillation detectors used in coincidence counting. (UK)

  2. Estimation of potassium concentration in coconut water by beta radioactivity measurement

    International Nuclear Information System (INIS)

    Reddy, P.J.; Narayani, K.; Bhade, S.P.D.; Anilkumar, S.; Kolekar, R.V.; Singh, Rajvir; Pradeepkumar, K.S.

    2014-01-01

    Potassium is widely distributed in soil, in all vegetable, fruits and animal tissues. Approximately half the radioactivity found in humans comes from 40 K. Potassium is an essential element in our diet since it is required for proper nerve and muscle function, as well as for maintaining the fluid balance of cells and heart rhythm. Potassium can enter the body mainly consuming fruits, vegetables and food. Tender coconut water is consumed widely as natural refreshing drink which is rich in potassium. The simple way to determine 40 K activity is by gamma ray spectrometry. However, the low abundance of this gamma photon makes the technique less sensitive compared to gross beta measurement. Many analytical methods are reported for potassium estimation which is time consuming and destructive in nature. A unique way to estimate 40 K by beta activity is by Cerenkov Counting technique using Liquid Scintillation Analyzer. Also much lower detection limit is achieved, allowing for greater precision. In this work, we have compared two methods to arrive at the potassium concentration in tender and matured coconut water by measuring 40 K. One is non-scintillator method based on measurement of the Cerenkov radiation generated from the high-energy β of 40 K. The second method is based on beta activity measurement using low background Gas flow counter

  3. Correction to the count-rate detection limit and sample/blank time-allocation methods

    International Nuclear Information System (INIS)

    Alvarez, Joseph L.

    2013-01-01

    A common form of count-rate detection limits contains a propagation of uncertainty error. This error originated in methods to minimize uncertainty in the subtraction of the blank counts from the gross sample counts by allocation of blank and sample counting times. Correct uncertainty propagation showed that the time allocation equations have no solution. This publication presents the correct form of count-rate detection limits. -- Highlights: •The paper demonstrated a proper method of propagating uncertainty of count rate differences. •The standard count-rate detection limits were in error. •Count-time allocation methods for minimum uncertainty were in error. •The paper presented the correct form of the count-rate detection limit. •The paper discussed the confusion between count-rate uncertainty and count uncertainty

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... Like this video? Sign in to make your opinion count. Sign in 131 2 Don't like this video? Sign in to make your opinion count. Sign in 3 Loading... Loading... Transcript The ...

  5. The Big Pumpkin Count.

    Science.gov (United States)

    Coplestone-Loomis, Lenny

    1981-01-01

    Pumpkin seeds are counted after students convert pumpkins to jack-o-lanterns. Among the activities involved, pupils learn to count by 10s, make estimates, and to construct a visual representation of 1,000. (MP)

  6. The Gross-Llewellyn Smith sum rule

    International Nuclear Information System (INIS)

    Scott, W.G.

    1981-01-01

    We present the most recent data on the Gross-Llewellyn Smith sum rule obtained from the combined BEBC Narrow Band Neon and GGM-PS Freon neutrino/antineutrino experiments. The data for the Gross-Llewellyn Smith sum rule as a function of q 2 suggest a smaller value for the QCD coupling constant parameter Λ than is obtained from the analysis of the higher moments. (author)

  7. Validating the Rett Syndrome Gross Motor Scale.

    Directory of Open Access Journals (Sweden)

    Jenny Downs

    Full Text Available Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age and genotype were investigated. Clinical assessment scores for 38 girls and women with Rett syndrome who attended the Danish Center for Rett Syndrome were used to assess consistency of measurement. Principal components analysis enabled the calculation of three factor scores: Sitting, Standing and Walking, and Challenge. Motor scores were poorer with increasing age and those with the p.Arg133Cys, p.Arg294* or p.Arg306Cys mutation achieved higher scores than those with a large deletion. The repeatability of clinical assessment was excellent (intraclass correlation coefficient for total score 0.99, 95% CI 0.93-0.98. The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice and clinical trials.

  8. Validating the Rett Syndrome Gross Motor Scale.

    Science.gov (United States)

    Downs, Jenny; Stahlhut, Michelle; Wong, Kingsley; Syhler, Birgit; Bisgaard, Anne-Marie; Jacoby, Peter; Leonard, Helen

    2016-01-01

    Rett syndrome is a pervasive neurodevelopmental disorder associated with a pathogenic mutation on the MECP2 gene. Impaired movement is a fundamental component and the Rett Syndrome Gross Motor Scale was developed to measure gross motor abilities in this population. The current study investigated the validity and reliability of the Rett Syndrome Gross Motor Scale. Video data showing gross motor abilities supplemented with parent report data was collected for 255 girls and women registered with the Australian Rett Syndrome Database, and the factor structure and relationships between motor scores, age and genotype were investigated. Clinical assessment scores for 38 girls and women with Rett syndrome who attended the Danish Center for Rett Syndrome were used to assess consistency of measurement. Principal components analysis enabled the calculation of three factor scores: Sitting, Standing and Walking, and Challenge. Motor scores were poorer with increasing age and those with the p.Arg133Cys, p.Arg294* or p.Arg306Cys mutation achieved higher scores than those with a large deletion. The repeatability of clinical assessment was excellent (intraclass correlation coefficient for total score 0.99, 95% CI 0.93-0.98). The standard error of measurement for the total score was 2 points and we would be 95% confident that a change 4 points in the 45-point scale would be greater than within-subject measurement error. The Rett Syndrome Gross Motor Scale could be an appropriate measure of gross motor skills in clinical practice and clinical trials.

  9. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs.

  10. Radiation counting statistics

    Energy Technology Data Exchange (ETDEWEB)

    Suh, M. Y.; Jee, K. Y.; Park, K. K. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiments. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. 11 refs., 6 figs., 8 tabs. (Author)

  11. Radiation counting statistics

    International Nuclear Information System (INIS)

    Suh, M. Y.; Jee, K. Y.; Park, K. K.; Park, Y. J.; Kim, W. H.

    1999-08-01

    This report is intended to describe the statistical methods necessary to design and conduct radiation counting experiments and evaluate the data from the experiment. The methods are described for the evaluation of the stability of a counting system and the estimation of the precision of counting data by application of probability distribution models. The methods for the determination of the uncertainty of the results calculated from the number of counts, as well as various statistical methods for the reduction of counting error are also described. (Author). 11 refs., 8 tabs., 8 figs

  12. Total lymphocyte count and subpopulation lymphocyte counts in relation to dietary intake and nutritional status of peritoneal dialysis patients.

    Science.gov (United States)

    Grzegorzewska, Alicja E; Leander, Magdalena

    2005-01-01

    Dietary deficiency causes abnormalities in circulating lymphocyte counts. For the present paper, we evaluated correlations between total and subpopulation lymphocyte counts (TLC, SLCs) and parameters of nutrition in peritoneal dialysis (PD) patients. Studies were carried out in 55 patients treated with PD for 22.2 +/- 11.4 months. Parameters of nutritional status included total body mass, lean body mass (LBM), body mass index (BMI), and laboratory indices [total protein, albumin, iron, ferritin, and total iron binding capacity (TIBC)]. The SLCs were evaluated using flow cytometry. Positive correlations were seen between TLC and dietary intake of niacin; TLC and CD8 and CD16+56 counts and energy delivered from protein; CD4 count and beta-carotene and monounsaturated fatty acids 17:1 intake; and CD19 count and potassium, copper, vitamin A, and beta-carotene intake. Anorexia negatively influenced CD19 count. Serum albumin showed correlations with CD4 and CD19 counts, and LBM with CD19 count. A higher CD19 count was connected with a higher red blood cell count, hemoglobin, and hematocrit. Correlations were observed between TIBC and TLC and CD3 and CD8 counts, and between serum Fe and TLC and CD3 and CD4 counts. Patients with a higher CD19 count showed a better clinical-laboratory score, especially less weakness. Patients with a higher CD4 count had less expressed insomnia. Quantities of ingested vitamins and minerals influence lymphocyte counts in the peripheral blood of PD patients. Evaluation of TLC and SLCs is helpful in monitoring the effectiveness of nutrition in these patients.

  13. Method of measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1980-01-01

    A novel liquid scintillation counting method of measuring the disintegration rate of a beta-emitting radionuclide is described which involves counting the sample at at least two different quench levels. (UK)

  14. Design and development of multiple sample counting setup

    International Nuclear Information System (INIS)

    Rath, D.P.; Murali, S.; Babu, D.A.R.

    2010-01-01

    Full text: The analysis of active samples on regular basis for ambient air activity and floor contamination from radio chemical lab accounts for major chunk of the operational activity in Health Physicist's responsibility. The requirement for daily air sample analysis on immediate counting and delayed counting from various labs in addition to samples of smear swipe check of lab led to the urge for development of system that could cater multiple sample analysis in a time programmed manner on a single sample loading. A multiple alpha/beta counting system for counting was designed and fabricated. It has arrangements for loading 10 samples in slots in order, get counted in a time programmed manner with results displayed and records maintained in PC. The paper describes the design and development of multiple sample counting setup presently in use at the facility has resulted in reduction of man-hour consumption in counting and recording of the results

  15. Detection of Beta-Emitting Nuclides of Energy >1 Mev in Urine After an Accident by Means of Measurement of the Cerenkov Effect in a Liquid Scintillation Counting System; Detection des Radioelements Emetteurs Beta d'une Energie Superieure a 1 Mev dans l'Urine Apres un Accident, par la Mesure de l'Effet Cerenkov Avec un Ensemble de Comptage a Scintillation Liquide; 041e 0411 041d 0414 ; Deteccion en la Orina de Emisores Beta de Energia Superior a 1 Mev, Despues de un Accidente, por Medicion del Efecto Cerenkov en un Contador de Centelleador Liquido

    Energy Technology Data Exchange (ETDEWEB)

    Narrog, J. [Landesinstitut fuer Arbeitsschutz und Arbeitsmedizin, Karlsruhe, Federal Republic of Germany (Germany)

    1965-06-15

    Beta particles of energy >1 MeV in water can be measured by Cerenkov effect in liquid scintillation counters without any further preparation. Since Hoffman reported about this possibility at the Symposium held by the Gesellschaft Deutscher Chemiker (1-2 April 1964) in Karlsruhe-Leopoldshafen, experiments have been carried out in our institute to apply this method to urine. When experiments were carried out with unprepared urine, the measurements were insensitive because of the strong absorption effect. The urine must be cleared. Therefore we tried to oxidate with KMnO{sub 4} and got a clear liquid. The background was very high, because the K of the KMnO{sub 4} contains the radioactive K{sup 40}, which also emits {beta}-rays of energy > 1 MeV (1.32 MeV). We used Na MnO{sub 4} instead of KMnO{sub 4} and got better results. The background is now about 30 counts/min, the lower limit (measured with Sr{sup 90}/Y{sup 90}) about 1 pc/ml urine. If in accidents the content of radioactive K{sup 40} in urine cannot be assessed (e.g. by flame-photometry of the K-content in urine) this method gives the same sensitivity as other methods (e.g. bum and measure in a large-area proportional counting system), in this case (> 2 pc/ml). The measurement with the large-area proportional counter and additional assessment of the K{sup 40} {beta}-activity of the urine is mere sensitive and more accurate. This method is useful for a rapid measurement of large body burdens (and following excretion) of {beta}-nuclides of energy > 1 MeV, demanded by an accidental situation. With these methods we need no more than 90 min total time. (author) [French] On peut mesurer les particules beta d'une energie superieure a 1 MeV grace a l'effet Cerenkov dans des compteurs a scintillation liquide sans aucune autre preparation. Depuis que Hoffmann en a signale la possibilite a un colloque organise par la Gesellschaft Deutscher Chemiker les 1{sup er} et 2 avril 1964 a Karlsruhe-Leopoldshafen, l'auteur a

  16. Refined tropical curve counts and canonical bases for quantum cluster algebras

    DEFF Research Database (Denmark)

    Mandel, Travis

    We express the (quantizations of the) Gross-Hacking-Keel-Kontsevich canonical bases for cluster algebras in terms of certain (Block-Göttsche) weighted counts of tropical curves. In the process, we obtain via scattering diagram techniques a new invariance result for these Block-Göttsche counts....

  17. Assessment of beta-emitter radionuclides in biological samples using liquid scintillation counting. Application to the study of internal doses in molecular and cellular biology techniques; Evaluacion en muestras biologicas de radionucleidos emisores beta mediante espectrometria de centelleo en fase liquida. Aplicaciones al estudio de dosis internas en tecnicas de investigacion de biologia molecular y celular

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, I.; Delgado, A.; Navarro, T.; Macias, M. T.

    2007-07-01

    The radioisotopic techniques used in Molecular and Cellular Biology involve external and internal irradiation risk. It is necessary to control the possible internal contamination associated to the development of these techniques. The internal contamination risk can be due to physical and chemical properties of the labelled compounds, aerosols generated during the performance technique. The aim of this work was to estimate the possible intake of specific beta emitters during the technique development and to propose the required criterions to perform Individual Monitoring. The most representative radioisotopic techniques were selected attending their potential risk of internal contamination. Techniques were analysed applying IAEA methodology according to the used activity in each technique. It was necessary to identify the worker groups that would require individual monitoring on the base of their specific risk. Different measurement procedures were applied to study the possible intake in group risk and more than 160 persons were measured by in vitro bioassay. (Author) 96 refs.

  18. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    Science.gov (United States)

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  19. 26 CFR 1.61-1 - Gross income.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Gross income. 1.61-1 Section 1.61-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Definition of Gross Income, Adjusted Gross Income, and Taxable Income § 1.61-1 Gross...

  20. The determination of the optimum counting conditions for a ZnS(Ag) scintillation detector

    International Nuclear Information System (INIS)

    Djurasevic, M.M.; Kandic, A.B.; Novkovic, D.N; Vukanac, I.S. . E-mail address of corresponding author: mirad@vin.bg.ac.yu; Djurasevic, M.M.)

    2005-01-01

    The methods that use scintillation counting with ZnS(Ag) scintillation detector are widely used for gross alpha activity determination. The common criteria for the selection of optimum counting condition for a ZnS(Ag) scintillation detector do not consider simultaneously operating voltage and discrimination level variation. In presented method a relationship between voltage and discrimination level is derived for counting efficiency. (author)

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... 03. R Mayer 371,490 views 4:03 The psychological trick behind getting people to say yes - Duration: 8:06. PBS NewsHour 606,671 views 8:06 Should You Really Wash Your Hands? - Duration: 4:51. Gross Science 57,828 views 4:51 Healthcare Worker Hand ...

  2. Platelet Count and Plateletcrit

    African Journals Online (AJOL)

    strated that neonates with late onset sepsis (bacteremia after 3 days of age) had a dramatic increase in MPV and. PDW18. We hypothesize that as the MPV and PDW increase and platelet count and PCT decrease in sick children, intui- tively, the ratio of MPV to PCT; MPV to Platelet count,. PDW to PCT, PDW to platelet ...

  3. EcoCount

    Directory of Open Access Journals (Sweden)

    Phillip P. Allen

    2014-05-01

    Full Text Available Techniques that analyze biological remains from sediment sequences for environmental reconstructions are well established and widely used. Yet, identifying, counting, and recording biological evidence such as pollen grains remain a highly skilled, demanding, and time-consuming task. Standard procedure requires the classification and recording of between 300 and 500 pollen grains from each representative sample. Recording the data from a pollen count requires significant effort and focused resources from the palynologist. However, when an adaptation to the recording procedure is utilized, efficiency and time economy improve. We describe EcoCount, which represents a development in environmental data recording procedure. EcoCount is a voice activated fully customizable digital count sheet that allows the investigator to continuously interact with a field of view during the data recording. Continuous viewing allows the palynologist the opportunity to remain engaged with the essential task, identification, for longer, making pollen counting more efficient and economical. EcoCount is a versatile software package that can be used to record a variety of environmental evidence and can be installed onto different computer platforms, making the adoption by users and laboratories simple and inexpensive. The user-friendly format of EcoCount allows any novice to be competent and functional in a very short time.

  4. Clean Hands Count

    Medline Plus

    Full Text Available ... starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with ... ads? Get YouTube Red. Working... Not now Try it free Find out why Close Clean Hands Count ...

  5. Counting It Twice.

    Science.gov (United States)

    Schattschneider, Doris

    1991-01-01

    Provided are examples from many domains of mathematics that illustrate the Fubini Principle in its discrete version: the value of a summation over a rectangular array is independent of the order of summation. Included are: counting using partitions as in proof by pictures, combinatorial arguments, indirect counting as in the inclusion-exclusion…

  6. Set of counts by scintillations for atmospheric samplings

    International Nuclear Information System (INIS)

    Appriou, D.; Doury, A.

    1962-01-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies

  7. Gross Revenue risk in Swiss dairy farming

    NARCIS (Netherlands)

    Benni, El N.; Finger, R.

    2013-01-01

    This study investigated how agricultural policy reforms, including market liberalization and market deregulation, have influenced gross revenue risk of Swiss dairy producers using farm-level panel data between 1990 and 2009. Based on detrended data, variance decomposition was applied to assess how

  8. On the absolute measure of Beta activities

    International Nuclear Information System (INIS)

    Sanchez del Rio, C.; Jimenez Reynaldo, O.; Rodriguez Mayquez, E.

    1956-01-01

    A new method for absolute beta counting of solid samples is given. The mea surements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 65K ...

  10. Clean Hands Count

    Medline Plus

    Full Text Available ... Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed Unsubscribe 66K ...

  11. Housing Inventory Count

    Data.gov (United States)

    Department of Housing and Urban Development — This report displays the data communities reported to HUD about the nature of their dedicated homeless inventory, referred to as their Housing Inventory Count (HIC)....

  12. Allegheny County Traffic Counts

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — Traffic sensors at over 1,200 locations in Allegheny County collect vehicle counts for the Pennsylvania Department of Transportation. Data included in the Health...

  13. Counting Knights and Knaves

    Science.gov (United States)

    Levin,Oscar; Roberts, Gerri M.

    2013-01-01

    To understand better some of the classic knights and knaves puzzles, we count them. Doing so reveals a surprising connection between puzzles and solutions, and highlights some beautiful combinatorial identities.

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... why Close Clean Hands Count Centers for Disease Control and Prevention (CDC) Loading... Unsubscribe from Centers for Disease Control and Prevention (CDC)? Cancel Unsubscribe Working... Subscribe Subscribed ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. Working... Not now Try it free Find ...

  16. The Kruskal Count

    OpenAIRE

    Lagarias, Jeffrey C.; Rains, Eric; Vanderbei, Robert J.

    2001-01-01

    The Kruskal Count is a card trick invented by Martin J. Kruskal in which a magician "guesses" a card selected by a subject according to a certain counting procedure. With high probability the magician can correctly "guess" the card. The success of the trick is based on a mathematical principle related to coupling methods for Markov chains. This paper analyzes in detail two simplified variants of the trick and estimates the probability of success. The model predictions are compared with simula...

  17. Activity level of gross α and gross β in airborne aerosol samples around the Qinshan NPP

    International Nuclear Information System (INIS)

    Chen Bin; Ye Jida; Chen Qianyuan; Wu Xiaofei; Song Weili; Wang Hongfeng

    2007-01-01

    The monitoring results of gross α and gross 13 activity from 2001 to 2005 for environmental airborne aerosol samples around the Qinshan NPP base are presented in this paper. A total of 170 aerosol samples were collected from monitoring sites of Caichenmen village, Qinlian village, Xiajiawan village and Yangliucun village around the Qinshan NPP base. The measured specific activity of gross α and gross β are in the range of 0.02-0.38 mBq/m 3 and 0.10-1.81 mBq/m 3 , respectively, with an average of 0.11 mBq/m 3 and 0.45mBq/m 3 , respectively. They are lower than the average of 0.15 mBq/m 3 and 0.52 mBq/m 3 , of reference site at Hangzhou City. It is indicated that the specific activity of gross α and gross β for environmental aerosol samples around the Qinshan NPP base had not been increased in normal operating conditions of the NPP. (authors)

  18. TERATOGENIC EFFECTS OF SILVER NANOPARTICLES: GROSS ANOMALIES

    OpenAIRE

    Jyoti Prakash; Rajniti; Deepika; Royana

    2015-01-01

    BACK GROUND: Prenatal exposure of AgNPs can induces devastative and detrimental effect in the organogenesis period of the developing embryos and foetuses. Organogenesis period is highly condemnatory and persuadable. Any injury to embryo during this period leads to dysmorphogenesis or even death AIM: The present study means to evaluate the gross anomalies on developing f o etus subsequent to silver nanoparticle ingestion during the gestational period. ...

  19. Low White Blood Cell Count

    Science.gov (United States)

    Symptoms Low white blood cell count By Mayo Clinic Staff A low white blood cell count (leukopenia) is a decrease ... of white blood cell (neutrophil). The definition of low white blood cell count varies from one medical ...

  20. Recent progress with digital coincidence counting

    International Nuclear Information System (INIS)

    Butcher, K.S.A.; Watt, G.C.; Alexiev, D.

    1999-01-01

    Digital Coincidence Counting (DCC) is a new technique, based on the older method of analogue coincidence counting. It has been developed by ANSTO as a faster more reliable means of determining the activity of ionising radiation samples. The technique employs a dual channel analogue to digital converter acquisition system for collecting pulse information from a 4Π beta detector and a NaI(Tl) gamma detector. The digitised pulse information is stored on a high speed hard disk and timing information for both channels is also stored. The data may subsequently be recalled and analysed using software based algorithms. The system is operational and results are now being routinely collected and analysed. Some of the early work is presented for Co-60, Na-22 and Sm-153

  1. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  2. Principles of correlation counting

    International Nuclear Information System (INIS)

    Mueller, J.W.

    1975-01-01

    A review is given of the various applications which have been made of correlation techniques in the field of nuclear physics, in particular for absolute counting. Whereas in most cases the usual coincidence method will be preferable for its simplicity, correlation counting may be the only possible approach in such cases where the two radiations of the cascade cannot be well separated or when there is a longliving intermediate state. The measurement of half-lives and of count rates of spurious pulses is also briefly discussed. The various experimental situations lead to different ways the correlation method is best applied (covariance technique with one or with two detectors, application of correlation functions, etc.). Formulae are given for some simple model cases, neglecting dead-time corrections

  3. Interpretation of galaxy counts

    International Nuclear Information System (INIS)

    Tinsely, B.M.

    1980-01-01

    New models are presented for the interpretation of recent counts of galaxies to 24th magnitude, and predictions are shown to 28th magnitude for future comparison with data from the Space Telescope. The results supersede earlier, more schematic models by the author. Tyson and Jarvis found in their counts a ''local'' density enhancement at 17th magnitude, on comparison with the earlier models; the excess is no longer significant when a more realistic mixture of galaxy colors is used. Bruzual and Kron's conclusion that Kron's counts show evidence for evolution at faint magnitudes is confirmed, and it is predicted that some 23d magnitude galaxies have redshifts greater than unity. These may include spheroidal systems, elliptical galaxies, and the bulges of early-type spirals and S0's, seen during their primeval rapid star formation

  4. Interpretation of serum antibody response to Anoplocephala perfoliata in relation to parasite burden and faecal egg count

    DEFF Research Database (Denmark)

    Kjaer, L.N.; Lungholt, M.M.; Nielsen, M.K.

    2007-01-01

    of development and gross pathological mucosal lesions were recorded and compared with serum antibody responses and faecal egg counts. Faecal egg counts were determined in samples from A. perfoliata infected horses using a semi-quantitative centrifugation/flotation technique. Blood samples collected at slaughter...

  5. Computerized radioautographic grain counting

    International Nuclear Information System (INIS)

    McKanna, J.A.; Casagrande, V.A.

    1985-01-01

    In recent years, radiolabeling techniques have become fundamental assays in physiology and biochemistry experiments. They also have assumed increasingly important roles in morphologic studies. Characteristically, radioautographic analysis of structure has been qualitative rather than quantitative, however, microcomputers have opened the door to several methods for quantifying grain counts and density. The overall goal of this chapter is to describe grain counting using the Bioquant, an image analysis package based originally on the Apple II+, and now available for several popular microcomputers. The authors discuss their image analysis procedures by applying them to a study of development in the central nervous system

  6. Rainflow counting revisited

    Energy Technology Data Exchange (ETDEWEB)

    Soeker, H [Deutsches Windenergie-Institut (Germany)

    1996-09-01

    As state of the art method the rainflow counting technique is presently applied everywhere in fatigue analysis. However, the author feels that the potential of the technique is not fully recognized in wind energy industries as it is used, most of the times, as a mere data reduction technique disregarding some of the inherent information of the rainflow counting results. The ideas described in the following aim at exploitation of this information and making it available for use in the design and verification process. (au)

  7. The Gross Motor Skills of Children with Mild Learning Disabilities

    Science.gov (United States)

    Nonis, Karen P.; Jernice, Tan Sing Yee

    2014-01-01

    Many international studies have examined the gross motor skills of children studying in special schools while local studies of such nature are limited. This study investigated the gross motor skills of children with Mild Learning Disabilities (MLD; n = 14, M age = 8.93 years, SD = 0.33) with the Test of Gross Motor Development-2 (TGMD-2, Ulrich,…

  8. 75 FR 78897 - Definition of Omission From Gross Income

    Science.gov (United States)

    2010-12-17

    ... Definition of Omission From Gross Income AGENCY: Internal Revenue Service (IRS), Treasury. ACTION: Final regulations. SUMMARY: This document contains final regulations defining an omission from gross income for... overstatement of basis in a sold asset results in an omission from gross income. The regulations will affect any...

  9. Beta Emission and Bremsstrahlung

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-13

    Bremsstrahlung is continuous radiation produced by beta particles decelerating in matter; different beta emitters have different endpoint energies; high-energy betas interacting with high-Z materials will more likely produce bremsstrahlung; depending on the data, sometimes all you can say is that a beta emitter is present.

  10. Water quality - Measurement of gross alpha activity in non-saline water - Thick source method. 2. ed.

    International Nuclear Information System (INIS)

    2007-01-01

    This International Standard specifies a method for the determination of gross alpha activity in non-saline waters for alpha-emitting radionuclides which are not volatile at 350 degree Centigrade. It is possible to determine supported volatile radionuclides measured to an extent determined by half-life, matrix retention (of the volatile species) and the duration of measurement (counting time). The method is applicable to raw and potable waters. The range of application depends on the amount of suspended matter in the water and on the performance characteristics (background count rate and counting efficiency) of the counter. Gross alpha radioactivity is determined by using proportional counting or solid scintillation counting on water residue deposited on a planchet. Due to the strong absorption of the residue deposit, it is considered that the alpha emission from the surface is proportional to the alpha activity of the deposit. Gross alpha determination is not an absolute determination of the sample alpha radioactive content, but a relative determination referring to a specific alpha emitter which constitutes the standard calibration source. This type of determination is also known as alpha index. The sample is acidified to stabilize it, evaporated almost to dryness, converted to the sulfate form and then ignited at 350 degree Centigrade. A portion of the residue is transferred to a planchet and the alpha activity measured by counting in an alpha-particle detector or counting system previously calibrated against an alpha-emitting standard and the alpha activity concentration calculated. The paper provides information about scope, normative references, symbols, definitions and units, principle, reagents and equipment, procedure, contamination check, expression of results and test report

  11. Gross shell structure of moments of inertia

    International Nuclear Information System (INIS)

    Deleplanque, M.A.; Frauendorf, S.; Pashkevich, V.V.; Chu, S.Y.; Unzhakova, A.

    2002-01-01

    Average yrast moments of inertia at high spins, where the pairing correlations are expected to be largely absent, were found to deviate from the rigid-body values. This indicates that shell effects contribute to the moment of inertia. We discuss the gross dependence of moments of inertia and shell energies on the neutron number in terms of the semiclassical periodic orbit theory. We show that the ground-state shell energies, nuclear deformations and deviations from rigid-body moments of inertia are all due to the same periodic orbits

  12. Solitons in Gross-Pitaevskii equation

    International Nuclear Information System (INIS)

    Lopes, E.

    1985-01-01

    It is observed that, when the potential is integrable and repulsive, the Gross-Pitaevskii Equation, with non-vanishing boundary conditions, describes a family of planar solitons. A method is presented which provides an exact soliton field to the Dirac Delta potential and an approximation solution to any other kind of potential. As an example the method is then applied to the case of a repulsive Yukawa potential. A brief discuss the relation between these solitons and Anderson's superfluidity mechanism, is also presented. (author) [pt

  13. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 824 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 409,492 ...

  14. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 786 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,702 ...

  15. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 414 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  16. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 869 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  17. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 460 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  18. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 741 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  19. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 029 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  20. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 396 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  1. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 094 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,974 ...

  2. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 319 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  3. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 585 views 3:10 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 413,097 ...

  4. Detection and counting systems

    International Nuclear Information System (INIS)

    Abreu, M.A.N. de

    1976-01-01

    Detection devices based on gaseous ionization are analysed, such as: electroscopes ionization chambers, proportional counters and Geiger-Mueller counters. Scintillation methods are also commented. A revision of the basic concepts in electronics is done and the main equipment for counting is detailed. In the study of gama spectrometry, scintillation and semiconductor detectors are analysed [pt

  5. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 384 views 1:19 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Thomas Jefferson University & Jefferson ...

  6. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 285 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  7. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 033 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 410,052 ...

  8. Reticulocyte Count Test

    Science.gov (United States)

    ... htm. (2004 Summer). Immature Reticulocyte Fraction(IRF). The Pathology Center Newsletter v9(1). [On-line information]. Available ... Company, Philadelphia, PA [18th Edition]. Levin, M. (2007 March 8, Updated). Reticulocyte Count. MedlinePlus Medical Encyclopedia [On- ...

  9. Clean Hands Count

    Medline Plus

    Full Text Available ... is starting stop Loading... Watch Queue Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos ... empower patients to play a role in their care by asking or reminding healthcare providers to clean ...

  10. Radiation intensity counting system

    International Nuclear Information System (INIS)

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  11. Clean Hands Count

    Medline Plus

    Full Text Available ... Queue __count__/__total__ It’s YouTube. Uninterrupted. Loading... Want music and videos with zero ads? Get YouTube Red. ... 043 views 1:36 Wash 'Em - Hand Hygiene Music Video - Duration: 5:46. Jefferson Health 411,292 ...

  12. Calorie count - fast food

    Science.gov (United States)

    ... GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Calorie count - fast food URL of this page: //medlineplus.gov/ency/patientinstructions/ ...

  13. Fast counting electronics for neutron coincidence counting

    International Nuclear Information System (INIS)

    Swansen, J.E.

    1987-01-01

    This patent describes a high speed circuit for accurate neutron coincidence counting comprising: neutron detecting means for providing an above-threshold signal upon neutron detection; amplifying means inputted by the neutron detecting means for providing a pulse output having a pulse width of about 0.5 microseconds upon the input of each above threshold signal; digital processing means inputted by the pulse output of the amplifying means for generating a pulse responsive to each input pulse from the amplifying means and having a pulse width of about 50 nanoseconds effective for processing an expected neutron event rate of about 1 Mpps: pulse stretching means inputted by the digital processing means for producing a pulse having a pulse width of several milliseconds for each pulse received form the digital processing means; visual indicating means inputted by the pulse stretching means for producing a visual output for each pulse received from the digital processing means; and derandomizing means effective to receive the 50 ns neutron event pulses from the digital processing means for storage at a rate up to the neutron event rate of 1 Mpps and having first counter means for storing the input neutron event pulses

  14. On the absolute measure of Beta activities; Sobre la medida absoluta de actividades Beta

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez del Rio, C; Jimenez Reynaldo, O; Rodriguez Mayquez, E

    1956-07-01

    A new method for absolute beta counting of solid samples is given. The measurements is made with an inside Geiger-Muller tube of new construction. The backscattering correction when using an infinite thick mounting is discussed and results for different materials given. (Author)

  15. Counting efficiency for liquid scintillator systems with a single multiplier phototube

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1984-01-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs

  16. CD26 + CD4 + T cell counts and attack risk in interferon-treated multiple sclerosis

    DEFF Research Database (Denmark)

    Sellebjerg, F; Ross, C; Koch-Henriksen, Nils

    2005-01-01

    in patients with CD26 + CD4 + T cell counts above median, and this risk was independent of the risk conferred by neutralizing anti-IFN-beta antibodies. CD26 + CD4 + T cell counts may identify patients with MS at increased risk of attack during treatment with IFN-beta....... and CCR5 on T cells is altered in patients with active MS. We studied the expression of these molecules by flow cytometry in patients followed for six months during immunomodulatory treatment. In interferon (IFN)-beta-treated patients, we found that the hazard ratio for developing an attack was 28...

  17. Card controlled beta backscatter thickness measuring instrument

    International Nuclear Information System (INIS)

    Schlesinger, J.

    1978-01-01

    An improved beta backscatter instrument for the nondestructive measurement of the thickness of thin coatings on a substrate is described. Included therein is the utilization of a bank of memory stored data representative of isotope, substrate, coating material and thickness range characteristics in association with a control card having predetermined indicia thereon selectively representative of a particular isotope, substrate material, coating material and thickness range for conditioning electronic circuit means by memory stored data selected in accord with the predetermined indicia on a control card for converting backscattered beta particle counts into indicia of coating thickness

  18. Electrets for beta radiation detection

    International Nuclear Information System (INIS)

    Campos, L.L.; Caldas, L.V.E.; Mascarenhas, S.

    1983-01-01

    Electret dosimetry has been reviewed by Gross. A cylindrical electret ionization-chamber type dosimeter has been studied for X and gamma rays and neutrons. The principle of the dosimeter is electret charge compensation due to ionization in the chamber volume. Electret ionization chambers can be designed with one or more electrets and in various shapes. This study is concerned with a simple system, similar to a cylindrical ionization chamber (sensitive volume: 3,5 cm 3 ) using teflon electrets. Aluminum and lucite were used as wall-materials. Other experiences were performed using chambers without wall, i.e., without defined sensitive volume. The teflon electrets were obtained by Corona discharge in the gas surrounding them. The measurement of the electret charge was made by induction using a co-axial insulated metal chamber connected to an electrometer Keithley 610C. By measuring the charge before and after irradiation it is possible to obtain a calibration curve: charge (Q) versus absorbed dose (D) for the dosimeter. The irradiation setup used was the Beta Secondary Standard System of IPEN calibration laboratory with four beta sources: 90 Sr 90 Y (74 and 1850 MBq), 204 Tl (18,5 MBq) and 147 Pm (518 MBq). In some cases a 85 Kr source was also used. The electrets were tested in different radiation field geometries: electret axis parallel and perpendicular to the field. In conclusion, depending on the wall material and radiation field geometry, the teflon electret detector can be used for different dose interval determinations, using beta radiation

  19. Beta activity measurements in high, variable gamma backgrounds

    International Nuclear Information System (INIS)

    Stanga, D.; Sandu, E.; Craciun, L.

    1997-01-01

    In many cases beta activity measurements must be performed in high and variable gamma backgrounds. In such instances it is necessary to use well-shielded detectors but this technique is limited to laboratory equipment and frequently insufficient. In order to perform in a simple manner beta activity measurements in high and variable backgrounds a software-aided counting technique have been developed and a counting system have been constructed. This technique combines the different counting techniques with traditional method of successive measurement of the sample and background. The counting system is based on a programmable multi-scaler which is endowed with appropriate software and allow all operations to be performed via keyboard in an interactive fashion. Two large - area proportional detectors were selected in order to have the same background and the same gamma response within 5%. A program has been developed for the counting data analysis and beta activity computing. The software-aided counting technique has been implemented for beta activity measurement in high and variable backgrounds. (authors)

  20. GROSS- GAMMA RAY OBSERVATORY ATTITUDE DYNAMICS SIMULATOR

    Science.gov (United States)

    Garrick, J.

    1994-01-01

    The Gamma Ray Observatory (GRO) spacecraft will constitute a major advance in gamma ray astronomy by offering the first opportunity for comprehensive observations in the range of 0.1 to 30,000 megaelectronvolts (MeV). The Gamma Ray Observatory Attitude Dynamics Simulator, GROSS, is designed to simulate this mission. The GRO Dynamics Simulator consists of three separate programs: the Standalone Profile Program; the Simulator Program, which contains the Simulation Control Input/Output (SCIO) Subsystem, the Truth Model (TM) Subsystem, and the Onboard Computer (OBC) Subsystem; and the Postprocessor Program. The Standalone Profile Program models the environment of the spacecraft and generates a profile data set for use by the simulator. This data set contains items such as individual external torques; GRO spacecraft, Tracking and Data Relay Satellite (TDRS), and solar and lunar ephemerides; and star data. The Standalone Profile Program is run before a simulation. The SCIO subsystem is the executive driver for the simulator. It accepts user input, initializes parameters, controls simulation, and generates output data files and simulation status display. The TM subsystem models the spacecraft dynamics, sensors, and actuators. It accepts ephemerides, star data, and environmental torques from the Standalone Profile Program. With these and actuator commands from the OBC subsystem, the TM subsystem propagates the current state of the spacecraft and generates sensor data for use by the OBC and SCIO subsystems. The OBC subsystem uses sensor data from the TM subsystem, a Kalman filter (for attitude determination), and control laws to compute actuator commands to the TM subsystem. The OBC subsystem also provides output data to the SCIO subsystem for output to the analysts. The Postprocessor Program is run after simulation is completed. It generates printer and CRT plots and tabular reports of the simulated data at the direction of the user. GROSS is written in FORTRAN 77 and

  1. Determination of beta attenuation coefficients by means of timing method

    International Nuclear Information System (INIS)

    Ermis, E.E.; Celiktas, C.

    2012-01-01

    Highlights: ► Beta attenuation coefficients of absorber materials were found in this study. ► For this process, a new method (timing method) was suggested. ► The obtained beta attenuation coefficients were compatible with the results from the traditional one. ► The timing method can be used to determine beta attenuation coefficient. - Abstract: Using a counting system with plastic scintillation detector, beta linear and mass attenuation coefficients were determined for bakelite, Al, Fe and plexiglass absorbers by means of timing method. To show the accuracy and reliability of the obtained results through this method, the coefficients were also found via conventional energy method. Obtained beta attenuation coefficients from both methods were compared with each other and the literature values. Beta attenuation coefficients obtained through timing method were found to be compatible with the values obtained from conventional energy method and the literature.

  2. Sources of variability in the determination by evaporation method of gross alpha activity in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, A.; Corbacho, J.A. [LARUEX, Caceres (Spain). Environmental Radioactivity Lab.

    2013-07-01

    Determining the gross alpha activity concentration of water samples is one way to screen for waters whose radionuclide content is so high that its consumption could imply surpassing the Total Indicative Dose as defined in European Directive 98/83/EC. One of the most commonly used methods to prepare the sources to measure gross alpha activity in water samples is desiccation. Its main advantages are the simplicity of the procedure, the low cost of source preparation, and the possibility of simultaneously determining the gross beta activity. The preparation of the source, the construction of the calibration curves, and the measurement procedure itself involve, however, various factors that may introduce sufficient variability into the results to significantly affect the screening process. We here identify the main sources of this variability, and propose specific procedures to follow in the desiccation process that will reduce the uncertainties, and ensure that the result is indeed representative of the sum of the activities of the alpha emitters present in the sample. (orig.)

  3. Fractional Bhatnagar-Gross-Krook kinetic equation

    Science.gov (United States)

    Goychuk, Igor

    2017-11-01

    The linear Boltzmann equation (LBE) approach is generalized to describe fractional superdiffusive transport of the Lévy walk type in external force fields. The time distribution between scattering events is assumed to have a finite mean value and infinite variance. It is completely characterized by the two scattering rates, one fractional and a normal one, which defines also the mean scattering rate. We formulate a general fractional LBE approach and exemplify it with a particularly simple case of the Bohm and Gross scattering integral leading to a fractional generalization of the Bhatnagar, Gross and Krook (BGK) kinetic equation. Here, at each scattering event the particle velocity is completely randomized and takes a value from equilibrium Maxwell distribution at a given fixed temperature. We show that the retardation effects are indispensable even in the limit of infinite mean scattering rate and argue that this novel fractional kinetic equation provides a viable alternative to the fractional Kramers-Fokker-Planck (KFP) equation by Barkai and Silbey and its generalization by Friedrich et al. based on the picture of divergent mean time between scattering events. The case of divergent mean time is also discussed at length and compared with the earlier results obtained within the fractional KFP. Also a phenomenological fractional BGK equation without retardation effects is proposed in the limit of infinite scattering rates. It cannot be, however, rigorously derived from a scattering model, being rather clever postulated. It this respect, this retardationless equation is similar to the fractional KFP by Barkai and Silbey. However, it corresponds to the opposite, much more physical limit and, therefore, also presents a viable alternative.

  4. In vitro proliferation of adult human beta-cells.

    Directory of Open Access Journals (Sweden)

    Sabine Rutti

    Full Text Available A decrease in functional beta-cell mass is a key feature of type 2 diabetes. Glucagon-like peptide 1 (GLP-1 analogues induce proliferation of rodent beta-cells. However, the proliferative capacity of human beta-cells and its modulation by GLP-1 analogues remain to be fully investigated. We therefore sought to quantify adult human beta-cell proliferation in vitro and whether this is affected by the GLP-1 analogue liraglutide.Human islets from 7 adult cadaveric organ donors were dispersed into single cells. Beta-cells were purified by FACS. Non-sorted cells and the beta-cell enriched ("beta-cells" population were plated on extracellular matrix from rat (804G and human bladder carcinoma cells (HTB9 or bovine corneal endothelial ECM (BCEC. Cells were maintained in culture+/-liraglutide for 4 days in the presence of BrdU.Rare human beta-cell proliferation could be observed either in the purified beta-cell population (0.051±0.020%; 22 beta-cells proliferating out of 84'283 beta-cells counted or in the non-sorted cell population (0.055±0.011%; 104 proliferating beta-cells out of 232'826 beta-cells counted, independently of the matrix or the culture conditions. Liraglutide increased human beta-cell proliferation on BCEC in the non-sorted cell population (0.082±0.034% proliferating beta-cells vs. 0.017±0.008% in control, p<0.05.These results indicate that adult human beta-cell proliferation can occur in vitro but remains an extremely rare event with these donors and particular culture conditions. Liraglutide increases beta-cell proliferation only in the non-sorted cell population and only on BCEC. However, it cannot be excluded that human beta-cells may proliferate to a greater extent in situ in response to natural stimuli.

  5. Beta decay to the second 2+ excited state of 122Te

    International Nuclear Information System (INIS)

    Hayashi, Takeo; Yamada, Shigeru

    1976-01-01

    The first-forbidden beta transition in Sb-122 was studied by the angular correlation experiment and the beta-spectra. The special precautions were paid for counting the beta particles having energy lower than 750 keV in the beta-gamma angular correlation measurement. The sources of Sb-122 were obtained by irradiating enriched Sb-121 in the Kyoto University reactor. The reduced beta coefficient R(E) was obtained from the angular correlation function. The beta spectrum measurement was performed with a sector type double focusing beta-ray spectrometer. The R(E) values for the beta transitions were analyzed by using the simplex method as used by Manthuruthil and Poirier to compare the angular correlation data with the exact formula given by Morita and Morita. Sets of the nuclear matrix parameters thus obtained show that the condition for the cancellation effect is satisfied in the beta transition. (Kato, T.)

  6. Levered and unlevered Beta

    OpenAIRE

    Fernandez, Pablo

    2003-01-01

    We prove that in a world without leverage cost the relationship between the levered beta ( L) and the unlevered beta ( u) is the No-costs-of-leverage formula: L = u + ( u - d) D (1 - T) / E. We also analyze 6 alternative valuation theories proposed in the literature to estimate the relationship between the levered beta and the unlevered beta (Harris and Pringle (1985), Modigliani and Miller (1963), Damodaran (1994), Myers (1974), Miles and Ezzell (1980), and practitioners) and prove that all ...

  7. Relationship between habitual physical activity and gross motor skills is multifaceted in 5- to 8-year-old children.

    Science.gov (United States)

    Laukkanen, A; Pesola, A; Havu, M; Sääkslahti, A; Finni, T

    2014-04-01

    Adequate motor skills are essential for children participating in age-related physical activities, and gross motor skills may play an important role for maintaining sufficient level of physical activity (PA) during life course. The purpose of this study was to examine the relationship between gross motor skills and PA in children when PA was analyzed by both metabolic- and neuromuscular-based methods. Gross motor skills (KTK--Körperkoordinationstest für Kinder and APM inventory--manipulative skill test) of 84 children aged 5-8 years (53 preschoolers, 28 girls; 31 primary schoolers, 18 girls) were measured, and accelerometer-derived PA was analyzed using in parallel metabolic counts and neuromuscular impact methods. The gross motor skills were associated with moderate-to-high neuromuscular impacts, PA of vigorous metabolic intensity, and mean level of PA in primary school girls (0.5 motor skills (0.4 motor skills and PA stressing both metabolic and neuromuscular systems in children. Furthermore, PA highly stressing neuromuscular system interacts with gross motor proficiency in girls especially. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. CalCOFI Egg Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  9. Beta Thalassemia (For Parents)

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Beta Thalassemia KidsHealth / For Parents / Beta Thalassemia What's in this ... Symptoms Diagnosis Treatment Print en español Beta talasemia Thalassemias Thalassemias are a group of blood disorders that ...

  10. Effect of temperate climate tree species on gross ammonification, gross nitrification and N2O formation

    Science.gov (United States)

    Brüggemann, N.; Rosenkranz, P.; Papen, H.; Butterbach-Bahl, K.

    2003-04-01

    Microbial nitrogen turnover processes in the soil, like ammonification, nitrification and denitrification, play an important role in the formation of nitrous oxide (N2O): (i) ammonification, because it releases nitrogen from organic material in the form of ammonium (NH4+), which in turn can serve as substrate for nitrification; (ii) nitrification itself (i.e. the turnover of NH4+ to nitrate, NO3-), during which nitric oxide (NO) and N2O can be released as by-products at varying ratios; (iii) denitrification, in which NO3- serves as electron acceptor and is converted to molecular nitrogen (N2) via NO and N2O as intermediates, that can also be partially lost to the atmosphere. Temperate forest soils are a substantial source of atmospheric N2O contributing up to 10% to the total atmospheric N2O budget. However, this figure is afflicted with a huge uncertainty due to a number of factors governing the soil N2O formation, consumption, release and uptake, which are not fully understood at present. To one of these factors belongs the influence of the tree species on nitrogen turnover processes in the soil and the formation of N trace gases related with them. The aim of the present work was to analyse this tree species effect for the temperate climate region. For this purpose the effect of five different temperate tree species, having the same age and growing on the same soil in direct vicinity to each other, on gross ammonification and gross nitrification as well as on N2O formation was investigated. The trees (common beech, Fagus sylvatica; pedunculate oak, Quercus robur; Norway spruce, Picea abies; Japanese larch, Larix leptolepis; mountain pine, Pinus mugo) were part of a species trial in Western Jutland, Denmark, established in 1965 on a former sandy heathland. Samples from the soil under these five tree species were taken in spring and in summer 2002, respectively, differentiating between organic layer and mineral soil. The gross rates of ammonification as well of

  11. A study of gross morphological and histological syringeal features of ...

    African Journals Online (AJOL)

    A study of gross morphological and histological syringeal features of true francolins (Galliformes: Francolinus, Scleroptila, Peliperdix and Dendroperdix spp.) and spurfowls ( Pternistis spp.) in a phylogenetic context.

  12. Counting statistics in radioactivity measurements

    International Nuclear Information System (INIS)

    Martin, J.

    1975-01-01

    The application of statistical methods to radioactivity measurement problems is analyzed in several chapters devoted successively to: the statistical nature of radioactivity counts; the application to radioactive counting of two theoretical probability distributions, Poisson's distribution law and the Laplace-Gauss law; true counting laws; corrections related to the nature of the apparatus; statistical techniques in gamma spectrometry [fr

  13. Do your syringes count?

    International Nuclear Information System (INIS)

    Brewster, K.

    2002-01-01

    Full text: This study was designed to investigate anecdotal evidence that residual Sestamibi (MIBI) activity vaned in certain situations. For rest studies different brands of syringes were tested to see if the residuals varied. The period of time MIBI doses remained in the syringe between dispensing and injection was also considered as a possible source of increased residual counts. Stress Mibi syringe residual activities were measured to assess if the method of stress test affected residual activity. MIBI was reconstituted using 13 Gbq of Technetium in 3mls of normal saline then boiled for 10 minutes. Doses were dispensed according to department protocol and injected via cannula. Residual syringes were collected for three syringe types. In each case the barrel and plunger were measured separately. As the syringe is flushed during the exercise stress test and not the pharmacological stress test the chosen method was recorded. No relationship was demonstrated between the time MIBI remained in a syringe prior to injection and residual activity. Residual activity was not affected by method of stress test used. Actual injected activity can be calculated if the amount of activity remaining in the syringe post injection is known. Imaging time can be adjusted for residual activity to optimise count statistics. Preliminary results in this study indicate there is no difference in residual activity between syringe brands.Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  14. Cherenkov radiation effects on counting efficiency in extremely quenched liquid scintillation samples

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.; Rodriguez Barquero, L.

    1993-01-01

    The CIEMAT/NIST tracer method has successfully standardized nuclides with diverse quench values and decay schemes in liquid scintillation counting. However, the counting efficiency is computed inaccurately for extremely quenched samples. This article shows that when samples are extremely quenched, the counting efficiency in high-energy beta-ray nuclides depends principally on the Cherenkov effect. A new technique is described for quench determination, which makes the measurement of counting efficiency possible when scintillation counting approaches zero. A new efficiency computation model for pure beta-ray nuclides is also described. The results of the model are tested experimentally for 89 Sr, 90 Y, 36 Cl and 204 Tl nuclides with independence of the quench level. (orig.)

  15. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Bonicalzi, R. M.; Aalseth, C. E.; Day, A. R.; Hoppe, E. W.; Mace, E. K.; Moran, J. J.; Overman, C. T.; Panisko, M. E.; Seifert, A.

    2016-03-01

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill of P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium counting efficiency while minimizing radiocarbon beta decay interference.

  16. Forward-Looking Betas

    DEFF Research Database (Denmark)

    Christoffersen, Peter; Jacobs, Kris; Vainberg, Gregory

    Few issues are more important for finance practice than the computation of market betas. Existing approaches compute market betas using historical data. While these approaches differ in terms of statistical sophistication and the modeling of the time-variation in the betas, they are all backward......-looking. This paper introduces a radically different approach to estimating market betas. Using the tools in Bakshi and Madan (2000) and Bakshi, Kapadia and Madan (2003) we employ the information embedded in the prices of individual stock options and index options to compute our forward-looking market beta...

  17. Quality control of radiation counting systems and measurement of minimum detectable activity

    International Nuclear Information System (INIS)

    Song, Byoung Chul; Han, Sung Sim; Kim, Young Bok; Jee, Kwang Yong; Sohn, Se Chul

    2004-01-01

    Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the γ-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 dps within 20 confidence levels. The average alpha background level for the low background α/β counting system was 0.31 cpm and the efficiency for alpha counting was 34.38 %. The average beta background level for the α/β counting system was 1.30 cpm and the efficiency for beta counting was 46.5%. The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the γ-spectrometer was found to be 3.2 Bq/mL and 3.8 Bq/mL for the liquid scintillation counter, and 20.5 and 23.0 Bq/mL, respectively for the α and β counting system

  18. Discrimination indices as screening tests for beta-thalassemic trait.

    Science.gov (United States)

    Ntaios, George; Chatzinikolaou, Anastasia; Saouli, Zoi; Girtovitis, Fotios; Tsapanidou, Maria; Kaiafa, Georgia; Kontoninas, Zisis; Nikolaidou, Androula; Savopoulos, Christos; Pidonia, Ifigenia; Alexiou-Daniel, Stiliani

    2007-07-01

    The two most frequent microcytic anemias are beta-thalassemic trait (beta-TT) and iron deficiency anemia (IDA). Several discrimination indices have been proposed to distinguish between these two conditions. These indices are derived from several simple red blood cell indices, like red blood cell (RBC) count, mean cell volume, and RBC distribution width (RDW), as these are provided by electronic cell counters. The purpose of the study is to examine the diagnostic accuracy of six discrimination indices in the differentiation between IDA and beta-TT. The six discrimination indices that were examined were as follows: Mentzer Index (MI), Green & King Index (G&K), RDW Index (RDWI), England & Fraser Index (E&F), RDW, and RBC count. We calculated these indices on 373 patients (205 men, 168 women) with beta-TT and 120 patients (50 men, 70 women) with IDA, as well as their sensitivity, specificity, positive and negative prognostic value, efficiency, and Youden's index (YI). G&K shows the highest reliability, followed by E&F, RBC count, MI, and RDWI. On the contrary, RDW completely failed to differentiate between IDA and beta-TT. G&K proved to be the most reliable index as it had the highest sensitivity (75.06%), efficiency (80.12%), and YI (70.86%) for the detection of beta-TT. These six discrimination indices cannot be relied on for a safe differential diagnosis between beta-TT and IDA. They do have high specificity, but their sensitivity for the detection of beta-TT is not satisfactory. Consequently, they cannot be used neither as a screening tool for beta-TT because they could result in a significant number of false negative results.

  19. Modal Logics with Counting

    Science.gov (United States)

    Areces, Carlos; Hoffmann, Guillaume; Denis, Alexandre

    We present a modal language that includes explicit operators to count the number of elements that a model might include in the extension of a formula, and we discuss how this logic has been previously investigated under different guises. We show that the language is related to graded modalities and to hybrid logics. We illustrate a possible application of the language to the treatment of plural objects and queries in natural language. We investigate the expressive power of this logic via bisimulations, discuss the complexity of its satisfiability problem, define a new reasoning task that retrieves the cardinality bound of the extension of a given input formula, and provide an algorithm to solve it.

  20. Digital coincidence counting

    International Nuclear Information System (INIS)

    Buckman, S.M.; Ius, D.

    1996-01-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method. (orig.)

  1. Digital coincidence counting

    Science.gov (United States)

    Buckman, S. M.; Ius, D.

    1996-02-01

    This paper reports on the development of a digital coincidence-counting system which comprises a custom-built data acquisition card and associated PC software. The system has been designed to digitise the pulse-trains from two radiation detectors at a rate of 20 MSamples/s with 12-bit resolution. Through hardware compression of the data, the system can continuously record both individual pulse-shapes and the time intervals between pulses. Software-based circuits are used to process the stored pulse trains. These circuits are constructed simply by linking together icons representing various components such as coincidence mixers, time delays, single-channel analysers, deadtimes and scalers. This system enables a pair of pulse trains to be processed repeatedly using any number of different methods. Some preliminary results are presented in order to demonstrate the versatility and efficiency of this new method.

  2. Analysis of low energy beta-emitters

    International Nuclear Information System (INIS)

    Murphy, D.L.

    1979-10-01

    A survey was made of the instruments used for the determination of low energy beta radioactivity. Techniques commonly used are gas flow proportional counting, liquid scintillation counting, solid scintillation counting, and internal ionization chamber counting, solid state detector counting, and radiochemical separation followed by counting using one of the preceeding techniques. The first four techniques were examined and compared with each other. The sensitivities of the techniques were compared on the basis of the detection limits quoted for instruments described in the technical and reviewed literature. The detection limits were then related to the occupational and public individual maximum levels for air and water. Attention is focused primarily on the continuous monitoring of air for 3 H and 85 Kr, a medium energy β-emitter. It is clear that several continuous air monitoring instruments are readily available for measuring low energy β concentrations, even in presence of certain other activity, at occupational levels. However, these instruments do not typically have sensitivities comparable to the public individual levels. Moreover, their capabilities for giving results in real time and for differentiating among the radionuclides actually present is limited

  3. 26 CFR 1.832-1 - Gross income.

    Science.gov (United States)

    2010-04-01

    ..., except that in the case of a mutual fire insurance company described in § 1.831-1 the amount of single... TAXES Other Insurance Companies § 1.832-1 Gross income. (a) Gross income as defined in section 832(b)(1... approved by the National Convention of Insurance Commissioners, as well as the gain derived from the sale...

  4. 26 CFR 1.993-6 - Definition of gross receipts.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 10 2010-04-01 2010-04-01 false Definition of gross receipts. 1.993-6 Section 1.993-6 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Domestic International Sales Corporations § 1.993-6 Definition of gross receipts. (a...

  5. 7 CFR 1424.7 - Gross payable units.

    Science.gov (United States)

    2010-01-01

    ... payments (APP), and base production payments (BPP). Repayment rates shall be based on previous payment... 50 gallons of net production increase. (2) For BPP, which will be made on production not eligible for... biodiesel production gross payable units. (3) Adding the APP and BPP to determine biodiesel gross payable...

  6. Guidelines for Standard Photography in Gross and Clinical Anatomy

    Science.gov (United States)

    Barut, Cagatay; Ertilav, Hakan

    2011-01-01

    Photography has a widespread usage in medicine and anatomy. In this review, authors focused on the usage of photography in gross and clinical anatomy. Photography in gross and clinical anatomy is not only essential for accurate documentation of morphological findings but also important in sharing knowledge and experience. Photographs of cadavers…

  7. Psychiatric Symptoms in Children with Gross Motor Problems

    Science.gov (United States)

    Emck, Claudia; Bosscher, Ruud J.; van Wieringen, Piet C. W.; Doreleijers, Theo; Beek, Peter J.

    2012-01-01

    Children with psychiatric disorders often demonstrate gross motor problems. This study investigates if the reverse also holds true by assessing psychiatric symptoms present in children with gross motor problems. Emotional, behavioral, and autism spectrum disorders (ASD), as well as psychosocial problems, were assessed in a sample of 40 children…

  8. Application of PSD for low level alpha counting using liquid scintillation counting

    International Nuclear Information System (INIS)

    Krishnamachari, G.; Vaze, P.K.; Iyer, M.R.

    1989-01-01

    In the liquid scintillator the light produced by alpha particles decays differently than those produced by electrons. Pulse shape discrimination (PSD) methods are employed to estimate low levels of alpha emitting radionuclides by reducing the background due to either beta or gamma events. An attempt is being made to develop a liquid scintillation counting sytem using a simple PSD circuit to achieve a background of 0.01 counts/min. The PSD circuit is based on measuring zero cross over points to differentiate particle types. The input signal is first differentiated by a delay line and subsequently by a RC circuit. The width of the initial part of the doubly differentiated pulse is different for alpha and beta pulses. This width is converted to amplitude by a time-to-amplitude converter (TAC). The higher amplitude pulses from the TAC are due to alpha particles and they are separated by an integral discriminator. The output from the integral discriminator opens a linear gate to record the pulse height spectrum. The figure of merit of the PSD circuit and background in the alpha energy channel have been worked out using different scintillator types. (author). 4 figs

  9. Bayesian approach in MN low dose of radiation counting

    International Nuclear Information System (INIS)

    Serna Berna, A.; Alcaraz, M.; Acevedo, C.; Navarro, J. L.; Alcanzar, M. D.; Canteras, M.

    2006-01-01

    The Micronucleus assay in lymphocytes is a well established technique for the assessment of genetic damage induced by ionizing radiation. Due to the presence of a natural background of MN the net MN is obtained by subtracting this value to the gross value. When very low doses of radiation are given the induced MN is close even lower than the predetermined background value. Furthermore, the damage distribution induced by the radiation follows a Poisson probability distribution. These two facts pose a difficult task to obtain the net counting rate in the exposed situations. It is possible to overcome this problem using a bayesian approach, in which the selection of a priori distributions for the background and net counting rate plays an important role. In the present work we make a detailed analysed using bayesian theory to infer the net counting rate in two different situations: a) when the background is known for an individual sample, using exact value value for the background and Jeffreys prior for the net counting rate, and b) when the background is not known and we make use of a population background distribution as background prior function and constant prior for the net counting rate. (Author)

  10. Counting statistics in low level radioactivity measurements fluctuating counting efficiency

    International Nuclear Information System (INIS)

    Pazdur, M.F.

    1976-01-01

    A divergence between the probability distribution of the number of nuclear disintegrations and the number of observed counts, caused by counting efficiency fluctuation, is discussed. The negative binominal distribution is proposed to describe the probability distribution of the number of counts, instead of Poisson distribution, which is assumed to hold for the number of nuclear disintegrations only. From actual measurements the r.m.s. amplitude of counting efficiency fluctuation is estimated. Some consequences of counting efficiency fluctuation are investigated and the corresponding formulae are derived: (1) for detection limit as a function of the number of partial measurements and the relative amplitude of counting efficiency fluctuation, and (2) for optimum allocation of the number of partial measurements between sample and background. (author)

  11. An electronic instructor for gross anatomy dissection.

    Science.gov (United States)

    Josephson, Eleanor M; Moore, Larry J

    2006-01-01

    Gross anatomy is time consuming to teach and to learn. Because the process of dissection takes up so much student time, assistance in the form of an in-lab instructional DVD program might improve student performance. The DVD could be viewed with a portable device by individual dissection groups at their tables. Groups could dissect at their own pace, with access to step-by-step demonstrations and answers to frequently asked anatomical questions. We created an instructional DVD program demonstrating dissection of the canine ventral neck and thoracic limb. The effect on student exam scores of using the DVD versus not using it was measured in a controlled, two-sample study using incoming first-year veterinary students as volunteers. Volunteers were told the study was of two different dissection methods; the DVD was not specifically mentioned until after the students were separated into two groups (Blue/DVD group and Orange/No DVD group), and then only to volunteers in the Blue group. Except for the DVD, the two groups had the same resources. The difference in scores on an exam given after a single dissection period did not differ sufficiently to conclude that DVD use raised the mean score; however, 73% of the DVD group scored 60% or higher, while only 38% of the No DVD group scored 60% or higher. The difference in mean scores overall was 2.3 points out of a possible 49, suggesting that the DVD helped students, especially those with lower scores, to earn two to three more points than they would have otherwise.

  12. Beta 2-adrenergic receptors are colocalized and coregulated with whisker barrels in rat somatosensory cortex

    International Nuclear Information System (INIS)

    Vos, P.; Kaufmann, D.; Hand, P.J.; Wolfe, B.B.

    1990-01-01

    Autoradiography has been used to visualize independently the subtypes of beta-adrenergic receptors in rat somatosensory cortex. Beta 2-adrenergic receptors, but not beta 1-adrenergic receptors colocalize with whisker barrels in this tissue. Thus, each whisker sends a specific multisynaptic pathway to the somatosensory cortex that can be histochemically visualized and only one subtype of beta-adrenergic receptor is specifically associated with this cortical representation. Additionally, neonatal lesion of any or all of the whisker follicles results in loss of the corresponding barrel(s) as shown by histochemical markers. This loss is paralleled by a similar loss in the organization of beta 2-adrenergic receptors in the somatosensory cortex. Other results indicate that these beta 2-adrenergic receptors are not involved in moment-to-moment signal transmission in this pathway and, additionally, are not involved in a gross way in the development of whisker-barrel array

  13. Betting Against Beta

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Heje Pedersen, Lasse

    We present a model with leverage and margin constraints that vary across investors and time. We find evidence consistent with each of the model’s five central predictions: (1) Since constrained investors bid up high-beta assets, high beta is associated with low alpha, as we find empirically for U...... of the BAB factor is low; (4) Increased funding liquidity risk compresses betas toward one; (5) More constrained investors hold riskier assets........S. equities, 20 international equity markets, Treasury bonds, corporate bonds, and futures; (2) A betting-against-beta (BAB) factor, which is long leveraged low beta assets and short high-beta assets, produces significant positive risk-adjusted returns; (3) When funding constraints tighten, the return...

  14. Roughing up Beta

    DEFF Research Database (Denmark)

    Bollerslev, Tim; Li, Sophia Zhengzi; Todorov, Viktor

    -section. An investment strategy that goes long stocks with high jump betas and short stocks with low jump betas produces significant average excess returns. These higher risk premiums for the discontinuous and overnight market betas remain significant after controlling for a long list of other firm characteristics......Motivated by the implications from a stylized equilibrium pricing framework, we investigate empirically how individual equity prices respond to continuous, or \\smooth," and jumpy, or \\rough," market price moves, and how these different market price risks, or betas, are priced in the cross......-section of expected returns. Based on a novel highfrequency dataset of almost one-thousand individual stocks over two decades, we find that the two rough betas associated with intraday discontinuous and overnight returns entail significant risk premiums, while the intraday continuous beta is not priced in the cross...

  15. Method validation for simultaneous counting of Total α , β in Drinking Water using Liquid Scintillation Counter

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.

    2014-05-01

    In this work, Method Validation Methods and Pulse Shape Analysis were validated to determine gross Alpha and Beta Emitters in Drinking Water using Liquid Scintillation Counter Win spectral 1414. Validation parameters include Method Detection Limit, Method Quantitation Limit, Repeatability Limit, Intermediate Precision, Trueness) Bias), Recovery Coefficient, Linearity and Uncertainty Budget in analysis. The results show that the Method Detection Limit and Method Quantitation Limit were 0.07, 0.24 Bq/l for Alpha emitters respectively, and 0.42, 1.4 Bq/l for Beta emitters, respectively. The relative standard deviation of Repeatability Limit reached 2.81% for Alpha emitters and 3.96% for Beta emitters. In addition to, the relative standard deviation of Intermediate Precisionis was 0.54% for Alpha emitters and 1.17% for Beta emitters. Moreover, the trueness was - 7.7% for Alpha emitters and - 4.5% for Beta emitters. Recovery Coefficient ranged between 87 - 96% and 88-101 for Alpha and Beta emitters, respectively. Linearity reached 1 for both Alpha and Beta emitters. on the other hand, Uncertainty Budget for all continents was 96.65% ,83.14% for Alpha and Beta emitters, respectively (author).

  16. Let's Make Data Count

    Science.gov (United States)

    Budden, A. E.; Abrams, S.; Chodacki, J.; Cruse, P.; Fenner, M.; Jones, M. B.; Lowenberg, D.; Rueda, L.; Vieglais, D.

    2017-12-01

    The impact of research has traditionally been measured by citations to journal publications and used extensively for evaluation and assessment in academia, but this process misses the impact and reach of data and software as first-class scientific products. For traditional publications, Article-Level Metrics (ALM) capture the multitude of ways in which research is disseminated and used, such as references and citations within social media and other journal articles. Here we present on the extension of usage and citation metrics collection to include other artifacts of research, namely datasets. The Make Data Count (MDC) project will enable measuring the impact of research data in a manner similar to what is currently done with publications. Data-level metrics (DLM) are a multidimensional suite of indicators measuring the broad reach and use of data as legitimate research outputs. By making data metrics openly available for reuse in a number of different ways, the MDC project represents an important first step on the path towards the full integration of data metrics into the research data management ecosystem. By assuring researchers that their contributions to scholarly progress represented by data corpora are acknowledged, data level metrics provide a foundation for streamlining the advancement of knowledge by actively promoting desirable best practices regarding research data management, publication, and sharing.

  17. LAWRENCE RADIATION LABORATORY COUNTING HANDBOOK

    Energy Technology Data Exchange (ETDEWEB)

    Group, Nuclear Instrumentation

    1966-10-01

    The Counting Handbook is a compilation of operational techniques and performance specifications on counting equipment in use at the Lawrence Radiation Laboratory, Berkeley. Counting notes have been written from the viewpoint of the user rather than that of the designer or maintenance man. The only maintenance instructions that have been included are those that can easily be performed by the experimenter to assure that the equipment is operating properly.

  18. Summarized report of geothermal well Gross Buchholz Gt1; Kurzprofil der Geothermiebohrung Gross Buchholz Gt1

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Frauke; Hesshaus, Annalena; Jatho, Reiner; Luppold, Friedrich-Wilhelm; Pletsch, Thomas; Tischner, Torsten [Bundesanstalt fuer Geowissenschaften und Rohstoffe (BGR), Hannover (Germany); Hunze, Sabine; Orilski, Judith; Wonik, Thomas [Leibniz-Institut fuer Angewandte Geophysik (LIAG), Hannover (Germany); Roehling, Heinz-Gerd [Landesamt fuer Bergbau, Energie und Geologie (LBEG), Hannover (Germany)

    2012-01-15

    The well Gross Buchholz Gt1 is a deep geothermal well intended to demonstrate the feasibility of deep geothermal energy mining from tight sedimentary rocks. It is the core part of the GeneSys (Generated Geothermal Energy Systems) project, aiming at developing single well concepts for direct use of geothermal energy. During the course of the project, three different single well concepts have been developed and tested at the research well Horstberg Z1 which is geologically comparable to the Gross Buchholzwell. The latter is intended to supply the heating energy for the premises of Geozentrum Hannover, an office and lab complex of some 35.000 m{sup 2} housing about 1000 employees. The geothermal target are the sandstones of the Lower Triassic Middle Buntsandstein Formation, which have a temperature of about 165 C at 3700 depth. The well has reached a final depth of 3901 m below ground level, penetrating a nearly complete succession from the Lower Cretaceous (Albian) to the Lower Triassic (Lower Buntsandstein), while Tertiary and Upper Cretaceous sediments are missing. This article summarizes technical and geographic data, stratigraphic classification, geophysical logging, cores, and sidewall cores of the well. (orig.)

  19. Beta limits for ETF

    International Nuclear Information System (INIS)

    Helton, F.J.; Miller, R.L.

    1982-01-01

    ETF (Engineering Test Facility) one-dimensional transport simulations indicate that a volume-average beta of 4% is required for ignition. It is therefore important that theoretical beta limits, determined by requiring equilibria to be stable to all ideal modes, exceed 4%. This paper documents an ideal MHD analysis wherein it is shown that, with appropriate plasma cross-sectional shape and current profile optimization, operation near 5% is possible. The critical beta value, however, depends on the functional form used for ff', which suggests that higher critical betas could be achieved by directly optimizing the safety factor profile. (author)

  20. SUMS Counts-Related Projects

    Data.gov (United States)

    Social Security Administration — Staging Instance for all SUMs Counts related projects including: Redeterminations/Limited Issue, Continuing Disability Resolution, CDR Performance Measures, Initial...

  1. Gross motor skill development of kindergarten children in Japan.

    Science.gov (United States)

    Aye, Thanda; Kuramoto-Ahuja, Tsugumi; Sato, Tamae; Sadakiyo, Kaori; Watanabe, Miyoko; Maruyama, Hitoshi

    2018-05-01

    [Purpose] The purposes of this study were to assess and explore the gender-based differences in gross motor skill development of 5-year-old Japanese children. [Subjects and Methods] This cross-sectional study recruited 60 healthy 5-year-old (third-year kindergarten, i.e., nencho ) children (34 boys, 26 girls) from one local private kindergarten school in Otawara city, Tochigi Prefecture, Japan. Gross motor skills, including six locomotor and six object control skills, were assessed using the test of gross motor development, second edition (TGMD-2). All subjects performed two trials of each gross motor skill, and the performances were video-recorded and scored. Assessment procedures were performed according to the standardized guidelines of the TGMD-2. [Results] The majority of subjects had an average level of overall gross motor skills. Girls had significantly better locomotor skills. Boys had significantly better object control skills. [Conclusion] The gross motor skill development of 5-year-old Japanese children involves gender-based differences in locomotor and object control skills. This study provided valuable information that can be used to establish normative references for the gross motor skills of 5-year-old Japanese children.

  2. Beta-energy averaging and beta spectra

    International Nuclear Information System (INIS)

    Stamatelatos, M.G.; England, T.R.

    1976-07-01

    A simple yet highly accurate method for approximately calculating spectrum-averaged beta energies and beta spectra for radioactive nuclei is presented. This method should prove useful for users who wish to obtain accurate answers without complicated calculations of Fermi functions, complex gamma functions, and time-consuming numerical integrations as required by the more exact theoretical expressions. Therefore, this method should be a good time-saving alternative for investigators who need to make calculations involving large numbers of nuclei (e.g., fission products) as well as for occasional users interested in restricted number of nuclides. The average beta-energy values calculated by this method differ from those calculated by ''exact'' methods by no more than 1 percent for nuclides with atomic numbers in the 20 to 100 range and which emit betas of energies up to approximately 8 MeV. These include all fission products and the actinides. The beta-energy spectra calculated by the present method are also of the same quality

  3. Compton suppression gamma-counting: The effect of count rate

    Science.gov (United States)

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  4. Monitoring of global alpha and beta radioactive level in the public water supply of Sao Paulo State, Brazil

    International Nuclear Information System (INIS)

    Peres, Ana Claudia

    2002-01-01

    The present work was based in the regulation number 1469 of Brazilian Health Ministry, of 2000, 29 th of December, that establishes the proceedings and responsibilities relatives to control and vigilance of water quality to human consumption and your gauge of potability. In the context the results of the analysis of the gross alpha and gross beta concentrations are presented. They were determined in 143 samples of drinking water supplies of Sao Paulo State in the year of 2001. The gross alpha presented concentrations ranging from <0,001 a 0,182 Bq/L, while the gross beta presented concentrations ranging from <0,001 a 0,872 Bq/L. (author)

  5. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    Energy Technology Data Exchange (ETDEWEB)

    Wiebe, L I; Helus, F; Maier-Borst, W [Deutsches Krebsforschungszentrum, Heidelberg (Germany, F.R.). Inst. fuer Nuklearmedizin

    1978-06-01

    /sup 18/F and /sup 14/C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched /sup 14/C fluorescence, and with a 10-fold excess of DMSO over MS, /sup 18/F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of /sup 18/F in MS. Nitrobenzene was a concentration-dependent quencher for both /sup 14/C and /sup 18/F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with /sup 18/F. Counting efficiencies for /sup 18/F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. /sup 14/C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high /sup 14/C and /sup 18/F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as /sup 18/F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as /sup 14/C.

  6. Cerenkov counting and Cerenkov-scintillation counting with high refractive index organic liquids using a liquid scintillation counter

    International Nuclear Information System (INIS)

    Wiebe, L.I.; Helus, F.; Maier-Borst, W.

    1978-01-01

    18 F and 14 C radioactivity was measured in methyl salicylate (MS), a high refractive index hybrid Cherenkov-scintillation generating medium, using a liquid scintillation counter. At concentrations of up to 21.4%, in MS, dimethyl sulfoxide (DMSO) quenched 14 C fluorescence, and with a 10-fold excess of DMSO over MS, 18 F count rates were reduced below that for DMSO alone, probably as a result of concentration-independent self-quenching due to 'dark-complex' formation. DMSO in lower concentrations did not reduce the counting efficiency of 18 F in MS. Nitrobenzene was a concentration-dependent quencher for both 14 C and 18 F in MS. Chlorobenzene (CB) and DMSO were both found to be weak Cherenkov generators with 18 F. Counting efficiencies for 18 F in MS, CB, and DMSO were 50.3, 7.8 and 4.3% respectively in the coincidence counting mode, and 58.1, 13.0 and 6.8% in the singles mode. 14 C efficiencies were 14.4 and 22.3% for coincidence and singles respectively, and 15.3 and 42.0% using a modern counter designed for coincidence and single photon counting. The high 14 C and 18 F counting efficiency in MS are discussed with respect to excitation mechanism, on the basis of quench and channels ratios changes observed. It is proposed that MS functions as an efficient Cherenkov-scintillation generator for high-energy beta emitters such as 18 F, and as a low-efficiency scintillator for weak beta emitting radionuclides such as 14 C. (author)

  7. Track counting in radon dosimetry

    International Nuclear Information System (INIS)

    Fesenbeck, Ingo; Koehler, Bernd; Reichert, Klaus-Martin

    2013-01-01

    The newly developed, computer-controlled track counting system is capable of imaging and analyzing the entire area of nuclear track detectors. The high optical resolution allows a new analysis approach for the process of automated counting using digital image processing technologies. This way, higher exposed detectors can be evaluated reliably by an automated process as well. (orig.)

  8. Use of sum-peak and coincidence counting methods for activity standardization of {sup 22}Na

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, E.M. de, E-mail: estela@ird.gov.br [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Iwahara, A.; Poledna, R. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Silva, M.A.L. da [Coordenacao Geral de Instalacoes Nucleares/Comissao Nacional de Energia Nuclear, R. Gal. Severiano, 90 - Botafogo, CEP 22290-901 Rio de Janeiro (Brazil); Tauhata, L. [Fundacao Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro (FAPERJ), Av. Erasmo Braga, 118-6 Degree-Sign andar, CEP 20020-000 Centro, Rio de Janeiro (Brazil); Delgado, J.U. [Laboratorio Nacional de Metrologia das Radiacoes Ionizantes (LNMRI/IRD/CNEN), Av. Salvador Allende, s/n, Recreio, CEP 22780-160 Rio de Janeiro (Brazil); Lopes, R.T. [Laboratorio de Instrumentacao Nuclear (LIN/PEN/COPPE/UFRJ), Caixa Postal 68509, CEP 21945-970 Rio de Janeiro (Brazil)

    2012-09-21

    A solution containing the positron emitter {sup 22}Na has been absolutely standardized using the 4{pi}{beta}-{gamma} coincidence counting method and the sum-peak spectrometry counting method. In the 4{pi}{beta}-{gamma} coincidence method two ways for the activity concentration measurements were used: gating on the 1275 keV photopeak and on the 1786 keV sum-peak where the knowledge of the {beta}{sup +}-branching ratio is required. In the sum-peak method the measurements were carried out using three experimental arrangements: the first composed by a well type 5 in. Multiplication-Sign 5 in. NaI(Tl) scintillation crystal, the second by a 3 in. Multiplication-Sign 3 in. NaI(Tl) scintillation crystal placed on the top of the first, resulting in a 4{pi} counting geometry and the third arrangement is a high purity coaxial germanium detector. The results that are obtained by these two methods are compatible within the standard uncertainty values with a coverage factor of k=2 ({approx}95% of the confidence level). This means that the sum-peak counting with its more simple experimental setup than the complex coincidence 4{pi}{beta}-{gamma} counting system gives consistent results for the activity standardization of {sup 22}Na with smaller uncertainties. Besides, the time period involved to attain the result of the standardization was quite shorter than the coincidence measurements used in this work.

  9. High beta tokamaks

    International Nuclear Information System (INIS)

    Dory, R.A.; Berger, D.P.; Charlton, L.A.; Hogan, J.T.; Munro, J.K.; Nelson, D.B.; Peng, Y.K.M.; Sigmar, D.J.; Strickler, D.J.

    1978-01-01

    MHD equilibrium, stability, and transport calculations are made to study the accessibility and behavior of ''high beta'' tokamak plasmas in the range β approximately 5 to 15 percent. For next generation devices, beta values of at least 8 percent appear to be accessible and stable if there is a conducting surface nearby

  10. Sorting out Downside Beta

    NARCIS (Netherlands)

    G.T. Post (Thierry); P. van Vliet (Pim); S.D. Lansdorp (Simon)

    2009-01-01

    textabstractDownside risk, when properly defined and estimated, helps to explain the cross-section of US stock returns. Sorting stocks by a proper estimate of downside market beta leads to a substantially larger cross-sectional spread in average returns than sorting on regular market beta. This

  11. Betting against Beta

    DEFF Research Database (Denmark)

    Frazzini, Andrea; Heje Pedersen, Lasse

    2014-01-01

    We present a model with leverage and margin constraints that vary across investors and time. We find evidence consistent with each of the model's five central predictions: (1) Because constrained investors bid up high-beta assets, high beta is associated with low alpha, as we find empirically...

  12. Galaxy number counts: Pt. 2

    International Nuclear Information System (INIS)

    Metcalfe, N.; Shanks, T.; Fong, R.; Jones, L.R.

    1991-01-01

    Using the Prime Focus CCD Camera at the Isaac Newton Telescope we have determined the form of the B and R galaxy number-magnitude count relations in 12 independent fields for 21 m ccd m and 19 m ccd m 5. The average galaxy count relations lie in the middle of the wide range previously encompassed by photographic data. The field-to-field variation of the counts is small enough to define the faint (B m 5) galaxy count to ±10 per cent and this variation is consistent with that expected from galaxy clustering considerations. Our new data confirm that the B, and also the R, galaxy counts show evidence for strong galaxy luminosity evolution, and that the majority of the evolving galaxies are of moderately blue colour. (author)

  13. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  14. Beta-delayed neutron decay of $^{33}$Na

    CERN Document Server

    Radivojevic, Z; Caurier, E; Cederkäll, J; Courtin, S; Dessagne, P; Jokinen, A; Knipper, A; Le Scornet, G; Lyapin, V G; Miehé, C; Nowacki, F; Nummela, S; Oinonen, M; Poirier, E; Ramdhane, M; Trzaska, W H; Walter, G; Äystö, J

    2002-01-01

    Beta-delayed neutron decay of /sup 33/Na has been studied using the on-line mass separator ISOLDE. The delayed neutron spectra were measured by time-of-flight technique using fast scintillators. Two main neutron groups at 800(60) and 1020(80) keV were assigned to the /sup 33/Na decay, showing evidence for strong feeding of states at about 4 MeV in /sup 33/Mg. By simultaneous beta - gamma -n counting the delayed neutron emission probabilities P/sub 1n/ = 47(6)% and P /sub 2n/ = 13(3)% were determined. The half-life value for /sup 33 /Na, T/sub 1/2/ = 8.0(3) ms, was measured by three different techniques, one employing identifying gamma transitions and two employing beta and neutron counting. (21 refs).

  15. Set of counts by scintillations for atmospheric samplings; Ensemble de comptages par scintillations pour prelevements atmospheriques

    Energy Technology Data Exchange (ETDEWEB)

    Appriou, D.; Doury, A.

    1962-07-01

    The author reports the development of a scintillation-based counting assembly with the following characteristics: a photo-multiplier with a wide photo-cathode, a thin plastic scintillator for the counting of beta + alpha (and possibility of mounting an alpha scintillator), a relatively small own motion with respect to activities to be counted, a weakly varying efficiency. The authors discuss the counting objective, present equipment tests (counter, proportional amplifier and pre-amplifier, input drawer). They describe the apparatus operation, discuss the selection of scintillators, report the study of the own movement (electron-based background noise, total background noise, background noise reduction), discuss counts (influence of the external source, sensitivity to alpha radiations, counting homogeneity, minimum detectable activity) and efficiencies.

  16. 26 CFR 1.61-4 - Gross income of farmers.

    Science.gov (United States)

    2010-04-01

    ... exchange is to be included in gross income. Proceeds of insurance, such as hail or fire insurance on... include crop insurance proceeds in income for taxable year following taxable year of destruction. For...

  17. Gross efficiency during rowing is not affected by stroke rate

    NARCIS (Netherlands)

    Hofmijster, M.J.; van Soest, A.J.; de Koning, J.J.

    2009-01-01

    Purpose: It has been suggested that the optimal stroke rate in rowing is partly determined by the stroke-rate dependence of internal power losses. This should be reflected in a stroke-rate dependency of gross efficiency (e

  18. A variational approach to the Gross-Neveu model

    International Nuclear Information System (INIS)

    Mishra, H.; Misra, P.; Mishra, A.

    1988-01-01

    The authors solve the instability of perturbative vacuum of Gross-Neveu model. They use a variational method. The analysis is nonperturbative as it uses only equal time commmutator/anticommutator algebra

  19. Genetics Home Reference: beta thalassemia

    Science.gov (United States)

    ... Facebook Twitter Home Health Conditions Beta thalassemia Beta thalassemia Printable PDF Open All Close All Enable Javascript to view the expand/collapse boxes. Description Beta thalassemia is a blood disorder that reduces the production ...

  20. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter); Determinacao de atividades alfa e beta total em agua para consumo humano por LSC (Contador de Cintilacao Liquida))

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-07-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  1. Rapid synthesis of beta zeolites

    Science.gov (United States)

    Fan, Wei; Chang, Chun -Chih; Dornath, Paul; Wang, Zhuopeng

    2015-08-18

    The invention provides methods for rapidly synthesizing heteroatom containing zeolites including Sn-Beta, Si-Beta, Ti-Beta, Zr-Beta and Fe-Beta. The methods for synthesizing heteroatom zeolites include using well-crystalline zeolite crystals as seeds and using a fluoride-free, caustic medium in a seeded dry-gel conversion method. The Beta zeolite catalysts made by the methods of the invention catalyze both isomerization and dehydration reactions.

  2. Determination of total alpha and beta activity in water for human consumption by LSC(Liquid Scintillation Counter)

    International Nuclear Information System (INIS)

    2013-01-01

    The Ordinance Brazilian of Ministry of Health (MS 2914/2011) establishes the standards for quality of water intended for human consumption, being limits values of 5.0 Bq/L for gross alpha, and 1.0 Bq/L for gross beta radioactivity. The liquid scintillation spectrometry (LSC) technique has been presented as an alternative to conventional procedure using gas flow proportional counter. The present work shows a review of the methods for determination of gross alpha and gross beta in water by using LSC. Between the factors that influence the accuracy and repeatability of the analytical results we can highlight: thermal preconcentration, type of the acid and calibration standard. A procedure was established and carried out to samples of the National Program of Intercomparison of Radionuclides in Environmental Samples for evaluation of its performance. The gross alpha and gross beta analysis in samples of the public water supplies in the Metropolitan Region of Goiania, state of Goias was carried out. The results are consistent with the guideline values form the Ministry of Health concerning radioactivity. (author)

  3. Alpha liquid scintillation counting: past, present, and future

    International Nuclear Information System (INIS)

    McDowell, W.J.

    1979-01-01

    Beta liquid scintillation counting has been used for about 30 years, and its effectiveness for alpha particles has been known for almost that long; however, the technique has not been widely applied to alpha particle detection because of poor energy resolution, high background, and variable interference from beta and gamma radiation. Beginning with the work of Horrocks in the early 1960s, improvements in energy resolution and background rejection have been made. Further developments at Oak Ridge National Laboratory over the past 10 to 12 years have resulted in improved methods of sample preparation (using liquid-liquid extraction methods to isolate the sample and introduce it into the scintillator) and better instrumentation, including electronic rejection of beta and gamma pulses. Energy resolutions of 200- to 300-keV FWHM and background counts of 0.01 cpm are now routine. Alpha liquid scintillation spectrometry is now suitable for a wide range of applications, from the accurate quantitative determination of relatively large amounts of known nuclides in laboratory-generated samples to the detection and identification of very small, subpicocurie amounts of alpha emitters in environmental-type samples. Suitable nuclide separation procedures, sample preparation methods, and instrument configurations are outlined for a variety of analyses

  4. In vivo counting of uranium

    International Nuclear Information System (INIS)

    Palmer, H.E.

    1985-03-01

    A state-of-the-art radiation detector system consisting of six individually mounted intrinsic germanium planar detectors, each 20 cm 2 by 13 mm thick, mounted together such that the angle of the whole system can be changed to match the slope of the chest of the person being counted, is described. The sensitivity of the system for counting uranium and plutonium in vivo and the precedures used in calibrating the system are also described. Some results of counts done on uranium mill workers are presented. 15 figs., 2 tabs

  5. [Hans Gross as an archaeologist--the significance of archaeology for 'encyclopedic' criminology].

    Science.gov (United States)

    Karl, Stephan; Bachhiesl, Christian

    2014-01-01

    In some cases, forensics and criminology have to cooperate with disciplines that usually are counted among the humanities, e.g. with archaeology. This article examines the significance of this cooperation for the criminological epistemology at the turn of the 19th century. These methodological considerations are illustrated by an example: When Hans Gross, who became the founder of the Austrian School of Criminology later, saw an unusually shaped hill near Feldbach, a town in southern Styria, he assumed this hill to be a burial mound and informed the responsible archaeological authorities immediately. Further investigations showed, however, that this hill was a natural formation. This is an early example for interdisciplinary cooperation, which proves that both in archaeology and in criminology a thorough inspection of the site is decisive for further scientific analysis of the topic of research.

  6. Beta-glucan ameliorates gamma-rays induced oxidative injury in male Swiss albino rats

    International Nuclear Information System (INIS)

    Salama, S.F.

    2011-01-01

    1,3-beta-D-Glucan is a natural polysaccharide derived from the cell walls of bakers yeast Saccharomyces cerevsiae with immunoenhancing and potent antioxidant effects. This study investigated the pathways through which beta-glucan gavage treatment (50mg/kg) exerts its effect on radiation-induced oxidative damage in male rats. Beta-glucan was given orally to male rats; 3 hours post gamma-irradiation at dose 5Gy, for 10 and 20 days post-irradiation level were assayed, being remarkable indicators in cell oxidative stress. Results pointed out that irradiation at 5Gy significantly depressed all blood parameters, such as erythrocytes count (RBCs), hemoglobin content (Hb), hematocrit value (Hct), total leucocytes count and absolute lymphocytes and neutrophils counts, blood glutathione (GSH) level and conversely elevated level of serum ascorbyl radical (AsR), product of lipid peroxidation (MDA melanodialdehyde), triglycerides and cholesterol. Total leucocytes count and absolute lymphocytes and neutrophils counts, RBCs, Hb, Hct, blood GSH and serum MDA of irradiated animals receiving beta-glucan administration were exhibited significant differences compared to the irradiated group. Marrow count and the percentage of viability and spleenocytes viability were also significantly decreased. Beta-glucan treatment accelerates recovery of cell damage induced by ionizing irradiation through its potential immune-enhancing activity and free radical scavenging ability that is partially mediated through stimulation of immunohaematological system thus could play a role in regulating irradiation complications

  7. Beta particle measurement fundamentals

    International Nuclear Information System (INIS)

    Alvarez, J.L.

    1986-01-01

    The necessary concepts for understanding beta particle behavior are stopping power, range, and scattering. Dose as a consequence of beta particle interaction with tissue can be derived and explained by these concepts. Any calculations of dose, however, assume or require detailed knowledge of the beta spectrum at the tissue depth of calculation. A rudimentary knowledge of the incident spectrum can be of use in estimating dose, interpretating dose measuring devices and designing protection. The stopping power and range based on the csda will give a conservative estimate in cases of protection design, as scattering will reduce the range. Estimates of dose may be low because scattering effects were neglected

  8. Gross and fine motor function in fibromyalgia and chronic fatigue syndrome.

    Science.gov (United States)

    Rasouli, Omid; Fors, Egil A; Borchgrevink, Petter Chr; Öhberg, Fredrik; Stensdotter, Ann-Katrin

    2017-01-01

    This paper aimed to investigate motor proficiency in fine and gross motor function, with a focus on reaction time (RT) and movement skill, in patients with fibromyalgia (FM) and chronic fatigue syndrome (CFS) compared to healthy controls (HC). A total of 60 individuals (20 CFS, 20 FM, and 20 HC), age 19-49 years, participated in this study. Gross motor function in the lower extremity was assessed using a RT task during gait initiation in response to an auditory trigger. Fine motor function in the upper extremity was measured during a precision task (the Purdue Pegboard test) where the number of pins inserted within 30 s was counted. No significant differences were found between FM and CFS in any parameters. FM and CFS groups had significantly longer RT than HC in the gait initiation ( p =0.001, and p =0.004 respectively). In the Purdue Pegboard test, 20% in the FM group, 15% in the CFS groups, and 0% of HC group, scored below the threshold of the accepted performance. However, there were no significant differences between FM, CFS, and HC in this task ( p =0.12). Compared to controls, both CFS and FM groups displayed significantly longer RT in the gait initiation task. Generally, FM patients showed the worst results in both tests, although no group differences were found in fine motor control, according to the Purdue Pegboard test.

  9. Optimization of simultaneous tritium–radiocarbon internal gas proportional counting

    Energy Technology Data Exchange (ETDEWEB)

    Bonicalzi, R.M. [Seattle Central College, 1701 Broadway, Seattle, WA 98122 (United States); Aalseth, C.E.; Day, A.R.; Hoppe, E.W. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States); Mace, E.K., E-mail: Emily.Mace@pnl.gov [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States); Moran, J.J.; Overman, C.T.; Panisko, M.E.; Seifert, A. [Pacific Northwest National Laboratory, 902 Battelle Boulevard, Richland, WA 99352 (United States)

    2016-03-21

    Specific environmental applications can benefit from dual tritium and radiocarbon measurements in a single compound. Assuming typical environmental levels, it is often the low tritium activity relative to the higher radiocarbon activity that limits the dual measurement. In this paper, we explore the parameter space for a combined tritium and radiocarbon measurement using a natural methane sample mixed with an argon fill gas in low-background proportional counters of a specific design. We present an optimized methane percentage, detector fill pressure, and analysis energy windows to maximize measurement sensitivity while minimizing count time. The final optimized method uses a 9-atm fill of P35 (35% methane, 65% argon), and a tritium analysis window from 1.5 to 10.3 keV, which stops short of the tritium beta decay endpoint energy of 18.6 keV. This method optimizes tritium-counting efficiency while minimizing radiocarbon beta-decay interference. - Highlights: • Use of a single compound (methane) for dual tritium and radiocarbon measurements. • Optimized analysis window for simultaneous tritium and radiocarbon measurement. • Allows for optimization of tritium counting in the presence of radiocarbon.

  10. Method for measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    1977-01-01

    A method of measuring the distintegration rate of a beta-emitting radionuclide in a liquid sample by counting at least two differently quenched versions of the sample. In each counting operation the sample is counted in the presence of and in the absence of a standard radioactive source. A pulse height (PH) corresponding to a unique point on the pulse height spectrum generated in the presence of the standard is determined. A zero threshold sample count rate (CPM) is derived by counting the sample once in a counting window having a zero threshold lower limit. Normalized values of the measured pulse heights (PH) are developed and correlated with the corresponding counts (CPM) to determine the pulse count for a normalized pulse height value of zero and hence the sample disintegration rate

  11. Method of measuring the disinteration rate of beta-emitting radionuclide in a liquid sample

    International Nuclear Information System (INIS)

    Horrocks, D.L.

    1977-01-01

    A method of measuring the disintegration rate of a beta-emitting radionuclide in a liquid sample by counting at least two differently quenched versions of the sample is described. In each counting operation the sample is counted in the presence of and in the absence of a standard radioactive source. A pulse height (PH) corresponding to a unique point on the pulse height spectrum generated in the presence of the standard is determined. A zero threshold sample count rate (CPM) is derived by counting the sample once in a counting window having a zero threshold lower limit. Normalized values of the measured pulse heights (PH) are developed and correlated with the corresponding pulse counts (CPM) to determine the pulse count for a normalized pulse height value of zero and hence the sample disintegration rate

  12. Complete Blood Count (For Parents)

    Science.gov (United States)

    ... Kids Deal With Injections and Blood Tests Blood Culture Anemia Blood Test: Basic Metabolic Panel (BMP) Blood Test: Hemoglobin Basic Blood Chemistry Tests Word! Complete Blood Count (CBC) Medical Tests and Procedures ( ...

  13. Make My Trip Count 2015

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — The Make My Trip Count (MMTC) commuter survey, conducted in September and October 2015 by GBA, the Pittsburgh 2030 District, and 10 other regional transportation...

  14. Counting Triangles to Sum Squares

    Science.gov (United States)

    DeMaio, Joe

    2012-01-01

    Counting complete subgraphs of three vertices in complete graphs, yields combinatorial arguments for identities for sums of squares of integers, odd integers, even integers and sums of the triangular numbers.

  15. Counting Word Frequencies with Python

    Directory of Open Access Journals (Sweden)

    William J. Turkel

    2012-07-01

    Full Text Available Your list is now clean enough that you can begin analyzing its contents in meaningful ways. Counting the frequency of specific words in the list can provide illustrative data. Python has an easy way to count frequencies, but it requires the use of a new type of variable: the dictionary. Before you begin working with a dictionary, consider the processes used to calculate frequencies in a list.

  16. Liquid scintillation counting of chlorophyll

    International Nuclear Information System (INIS)

    Fric, F.; Horickova, B.; Haspel-Horvatovic, E.

    1975-01-01

    A precise and reproducible method of liquid scintillation counting was worked out for measuring the radioactivity of 14 C-labelled chlorophyll a and chlorophyll b solutions without previous bleaching. The spurious count rate caused by luminescence of the scintillant-chlorophyll system is eliminated by using a suitable scintillant and by measuring the radioactivity at 4 to 8 0 C after an appropriate time of dark adaptation. Bleaching of the chlorophyll solutions is necessary only for measuring of very low radioactivity. (author)

  17. Experimental investigation of mass efficiency curve for alpha radioactivity counting using a gas-proportional detector

    International Nuclear Information System (INIS)

    Semkow, T.M.; Bari, A.; Parekh, P.P.; Haines, D.K.; Gao, H.; Bolden, A.N.; Dahms, K.S.; Scarpitta, S.C.; Thern, R.E.; Velazquez, S.

    2004-01-01

    Gross α counting of evaporated water residues offers a simple method for screening α radioactivity in water for both public health and emergency purposes. The evaporation process for water has been improved by using a combination of roughening of the surface of counting planchettes, two-stage evaporation, and temperature-controlled block heating. The efficiency of the gas-proportional detector for α-particle detection in water residues was studied as a function of sample mass-thickness in the range between 0.1 and 13 mg cm -2 . The effect of α energy on the efficiency, as well as moisture absorption on the samples, were studied using 230 Th, 238 U, 239 Pu, 241 Am, and 244 Cm radionuclides. Also, α-to-β crosstalk was investigated as a function of sample mass for 230 Th, 239 Pu, 210 Po, 241 Am, and 244 Cm. The improved method can also be applied for gross α detection in biological fluids

  18. Neutrinoless double beta decay

    Indian Academy of Sciences (India)

    2012-10-06

    Oct 6, 2012 ... Anyhow, the 'multi-isotope' ansatz is needed to compensate for matrix element ... The neccessary half-life requirement to touch this ... site energy depositions (like double beta decay) and multiple site interactions (most of.

  19. Beta-Carotene

    Science.gov (United States)

    ... disease (COPD). It is also used to improve memory and muscle strength. Some people use beta-carotene ... to reduce the chance of death and night blindness during pregnancy, as well as diarrhea and fever ...

  20. Double beta decay: experiments

    International Nuclear Information System (INIS)

    Fiorini, Ettore

    2006-01-01

    The results obtained so far and those of the running experiments on neutrinoless double beta decay are reviewed. The plans for second generation experiments, the techniques to be adopted and the expected sensitivities are compared and discussed

  1. {beta} - amyloid imaging probes

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Jae Min [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2007-04-15

    Imaging distribution of {beta} - amyloid plaques in Alzheimer's disease is very important for early and accurate diagnosis. Early trial of the {beta} -amyloid plaques includes using radiolabeled peptides which can be only applied for peripheral {beta} - amyloid plaques due to limited penetration through the blood brain barrier (BBB). Congo red or Chrysamine G derivatives were labeled with Tc-99m for imaging {beta} - amyloid plaques of Alzheimer patient's brain without success due to problem with BBB penetration. Thioflavin T derivatives gave breakthrough for {beta} - amyloid imaging in vivo, and a benzothiazole derivative [C-11]6-OH-BTA-1 brought a great success. Many other benzothiazole, benzoxazole, benzofuran, imidazopyridine, and styrylbenzene derivatives have been labeled with F-18 and I-123 to improve the imaging quality. However, [C-11]6-OH-BTA-1 still remains as the best. However, short half-life of C-11 is a limitation of wide distribution of this agent. So, it is still required to develop an Tc-99m, F-18 or I-123 labeled agent for {beta} - amyloid imaging agent.

  2. Standardization of 241Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting

    International Nuclear Information System (INIS)

    Balpardo, C.; Capoulat, M.E.; Rodrigues, D.; Arenillas, P.

    2010-01-01

    The nuclide 241 Am decays by alpha emission to 237 Np. Most of the decays (84.6%) populate the excited level of 237 Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of 241 Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

  3. Effect of water content nitrogen gross mineralization and immobilization

    International Nuclear Information System (INIS)

    Videla C, Ximena; Parada, Ana Maria; Nario M, Adriana; Pino N, Ines; Hood, Rebeca

    2005-01-01

    The decomposition of organic matter in soil, and the accompanying mineralization and immobilization of inorganic N, are key processes in the soil plant cycle. It is hypothesized that moisture regime may also play an important role on these processes. Two laboratory studies were carried out to investigate the effect of moisture regime on gross mineralization and immobilization of N, in and Ultisol soil, which was incubated at 25 o C, under two moisture regimes, field capacity (CC) (40% w/w) and 85% of field capacity (34% w/w): Using mirror image 15 N isotope dilution techniques, it was possible to determine gross nitrification and mineralization rates. The rates of gross mineralization and nitrification rate in this soil was extremely rapid and efficient, specially with 85% CC. The N transformations varied with moisture regime (author)

  4. The ionization quench factor in liquid-scintillation counting standardizations

    CERN Document Server

    Grau-Malonda, A

    1999-01-01

    We present a new detailed analysis of the ionization quench function Q(E) used in calculating the counting efficiency in liquid-scintillation counting (LSC), which shows that Q(0)=1, and permits one to derive Q(E) as a function of the electron energy and the parameter kB. The coefficients are tabulated by applying a new empirical formula of Q(E) for kB values in the range between 0.001 and 0.20 gMeV sup - sup 1 cm sup - sup 2. We demonstrate the convenience of applying sup 3 H and sup 5 sup 4 Mn for beta-ray and electron capture standardizations, respectively.

  5. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  6. Programmable automatic alpha--beta air sample counter

    International Nuclear Information System (INIS)

    Howell, W.P.

    1978-01-01

    A programmable automatic alpha-beta air sample counter was developed for routine sample counting by operational health physics personnel. The system is composed of an automatic sample changer utilizing a large silicon diode detector, an electronic counting system with energy analysis capability, an automatic data acquisition controller, an interface module, and a teletypewriter with paper tape punch and paper tape reader. The system is operated through the teletypewriter keyboard and the paper tape reader, which are used to instruct the automatic data acquisition controller. Paper tape programs are provided for background counting, Chi 2 test, and sample counting. Output data are printed by the teletypewriter on standard continuous roll or multifold paper. Data are automatically corrected for background and counter efficiency

  7. A simple method for calibration of Lucas scintillation cell counting system for measurement of 226Ra and 222Rn

    Directory of Open Access Journals (Sweden)

    N.K. Sethy

    2014-10-01

    Full Text Available Known quantity of radium from high grade ore solution was chemically separated and carefully kept inside the cavity of a Lucas Cell (LC. The 222Rn gradually builds up and attain secular equilibrium with its parent 226Ra. This gives a steady count after a suitable buildup period (>25 days. This secondary source was used to calibrate the radon counting system. The method is validated in by comparison with identical measurement with AlphaGuard Aquakit. The radon counting system was used to evaluate dissolved radon in ground water sample by gross alpha counting in LC. Radon counting system measures the collected radon after a delay of >180 min by gross alpha counting. Simultaneous measurement also carried out by AlphaGuard Aquakit in identical condition. AlphaGuard measures dissolved radon from water sample by constant aeration in a closed circuit without giving any delay. Both the methods are matching with a correlation coefficient of >0.9. This validates the calibration of Lucas scintillation cell counting system by designed encapsulated source. This study provides an alternative for calibration in absence of costly Radon source available in the market.

  8. Temporal trends in sperm count

    DEFF Research Database (Denmark)

    Levine, Hagai; Jørgensen, Niels; Martino-Andrade, Anderson

    2017-01-01

    a predefined protocol 7518 abstracts were screened and 2510 full articles reporting primary data on SC were reviewed. A total of 244 estimates of SC and TSC from 185 studies of 42 935 men who provided semen samples in 1973-2011 were extracted for meta-regression analysis, as well as information on years.......006, respectively). WIDER IMPLICATIONS: This comprehensive meta-regression analysis reports a significant decline in sperm counts (as measured by SC and TSC) between 1973 and 2011, driven by a 50-60% decline among men unselected by fertility from North America, Europe, Australia and New Zealand. Because......BACKGROUND: Reported declines in sperm counts remain controversial today and recent trends are unknown. A definitive meta-analysis is critical given the predictive value of sperm count for fertility, morbidity and mortality. OBJECTIVE AND RATIONALE: To provide a systematic review and meta-regression...

  9. Calibration of nuclides by gamma-gamma sum peak coincidence counting

    International Nuclear Information System (INIS)

    Guevara, E.A.

    1986-01-01

    The feasibility of extending sum peak coincidence counting to the direct calibration of gamma-ray emitters having particular decay schemes was investigated, also checkings of the measurement accuracy, by comparing with more precise beta-gamma coincidence counting have been performed. New theoretical studies and experiments were developed, demonstrating the reliability of the procedure. Uncertainties of less than one percent were obtained when certain radioactive sources were measured. The application of the procedure to 60 Co, 22 Na, 47 Ca and 148 Pm was studied. Theoretical bases of sum peak coincidence counting were set in order to extend it as an alternative method for absolute activity determination. In this respect, theoretical studies were performed for positive and negative beta decay, and electron capture, either accompanied or unaccompanied by coincident gamma rays. They include decay schemes containing up to three daughter nuclide excited levels, for different geometrical configurations. Equations are proposed for a possible generalization of the procedure. (M.E.L.) [es

  10. Boosted beta regression.

    Directory of Open Access Journals (Sweden)

    Matthias Schmid

    Full Text Available Regression analysis with a bounded outcome is a common problem in applied statistics. Typical examples include regression models for percentage outcomes and the analysis of ratings that are measured on a bounded scale. In this paper, we consider beta regression, which is a generalization of logit models to situations where the response is continuous on the interval (0,1. Consequently, beta regression is a convenient tool for analyzing percentage responses. The classical approach to fit a beta regression model is to use maximum likelihood estimation with subsequent AIC-based variable selection. As an alternative to this established - yet unstable - approach, we propose a new estimation technique called boosted beta regression. With boosted beta regression estimation and variable selection can be carried out simultaneously in a highly efficient way. Additionally, both the mean and the variance of a percentage response can be modeled using flexible nonlinear covariate effects. As a consequence, the new method accounts for common problems such as overdispersion and non-binomial variance structures.

  11. Photon-counting image sensors

    CERN Document Server

    Teranishi, Nobukazu; Theuwissen, Albert; Stoppa, David; Charbon, Edoardo

    2017-01-01

    The field of photon-counting image sensors is advancing rapidly with the development of various solid-state image sensor technologies including single photon avalanche detectors (SPADs) and deep-sub-electron read noise CMOS image sensor pixels. This foundational platform technology will enable opportunities for new imaging modalities and instrumentation for science and industry, as well as new consumer applications. Papers discussing various photon-counting image sensor technologies and selected new applications are presented in this all-invited Special Issue.

  12. Gross Motor Profile and Its Association with Socialization Skills in Children with Autism Spectrum Disorders

    OpenAIRE

    Hardiono D. Pusponegoro; Pustika Efar; Soedjatmiko; Amanda Soebadi; Agus Firmansyah; Hui-Ju Chen; Kun-Long Hung

    2016-01-01

    While social impairment is considered to be the core deficit in children with autism spectrum disorder (ASD), a large proportion of these children have poor gross motor ability, and gross motor deficits may influence socialization skills in children with ASD. The objectives of this study were to compare gross motor skills in children with ASD to typically developing children, to describe gross motor problems in children with ASD, and to investigate associations between gross motor and sociali...

  13. ϵ-expansion in the Gross-Neveu

    Energy Technology Data Exchange (ETDEWEB)

    Raju, Avinash [Center for High Energy Physics, Indian Institute of Science,Bangalore 560012 (India)

    2016-10-18

    We use the recently developed CFT techniques of Rychkov and Tan to compute anomalous dimensions in the O(N) Gross-Neveu model in d=2+ϵ dimensions. To do this, we extend the “cowpie contraction' algorithm of http://arxiv.org/abs/1506.06616 to theories with fermions. Our results match perfectly with Feynman diagram computations.

  14. Gross and microscopic lesions in corals from Micronesia

    Science.gov (United States)

    Work, Thierry M.; Aeby, Greta S.; Hughen, Konrad A.

    2015-01-01

    The authors documented gross and microscopic morphology of lesions in corals on 7 islands spanning western, southern, and eastern Micronesia, sampling 76 colonies comprising 30 species of corals among 18 genera, with Acropora, Porites, and Montipora dominating. Tissue loss comprised the majority of gross lesions sampled (41%), followed by discoloration (30%) and growth anomaly (29%). Of 31 cases of tissue loss, most lesions were subacute (48%), followed by acute and chronic (26% each). Of 23 samples with discoloration, most were dark discoloration (40%), with bleaching and other discoloration each constituting 30%. Of 22 growth anomalies, umbonate growth anomalies composed half, with exophytic, nodular, and rugose growth anomalies composing the remainder. On histopathology, for 9 cases of dark discoloration, fungal infections predominated (77%); for 7 bleached corals, depletion of zooxanthellae from the gastrodermis made up a majority of microscopic diagnoses (57%); and for growth anomalies other than umbonate, hyperplasia of the basal body wall was the most common microscopic finding (63%). For the remainder of the gross lesions, no single microscopic finding constituted >50% of the total. Host response varied with the agent present on histology. Fragmentation of tissues was most often associated with algae (60%), whereas necrosis dominated (53%) for fungi. Two newly documented potentially symbiotic tissue-associated metazoans were seen in Porites and Montipora. Findings of multiple potential etiologies for a given gross lesion highlight the importance of incorporating histopathology in coral disease surveys. This study also expands the range of corals infected with cell-associated microbial aggregates.

  15. Gross morphometric study on the reproductive system of Japanese ...

    African Journals Online (AJOL)

    Quail farming is emerging in commercial poultry farming to provide alternatives to domestic chicken production and also strengthen the poultry production demands for animal protein. This study was conducted to determine the gross morphometry of the ovary and oviduct of inapparently healthy adult laying Japanese quail ...

  16. Awareness and use of Gross Motor Function Classification System ...

    African Journals Online (AJOL)

    Introduction The degree of disability in children with Cerebral Palsy (CP) can be evaluated with the Gross Motor Function Classification System (GMFCS), a valid tool which was designed for such purposes. However, there appears to be paucity of data on the awareness and use of the GMFCS particularly in the ...

  17. Gross and morphometric anatomical changes of the thyroid gland in ...

    African Journals Online (AJOL)

    Gross and morphometric anatomical changes of the thyroid gland in the West African Dwarf Goat ( Capra hircus ) during the foetal and post-natal periods of development. ... The right lobe was more cranially located on the larynx and trachea than the left lobe in all age groups. Thyroid isthmus was absent in few foetal thyroid ...

  18. Survey On Management Systems And Gross Profit Analysis Of ...

    African Journals Online (AJOL)

    Survey On Management Systems And Gross Profit Analysis Of Muturu In Southern Cross River State. ... in muturu rearing for commercial purposes. Cost price of muturu within the study area was uniform due to the influence of market associations. The selling price of muturu cattle is however influenced by the location.

  19. Interlimb Coordination: An Important Facet of Gross-Motor Ability

    Science.gov (United States)

    Bobbio, Tatiana; Gabbard, Carl; Cacola, Priscila

    2009-01-01

    Motor development attains landmark significance during early childhood. Although early childhood educators may be familiar with the gross-motor skill category, the subcategory of interlimb coordination needs greater attention than it typically receives from teachers of young children. Interlimb coordination primarily involves movements requiring…

  20. 77 FR 51706 - Gross Combination Weight Rating (GCWR); Definition

    Science.gov (United States)

    2012-08-27

    ... [Docket No. FMCSA-2012-0156] RIN 2126-AB53 Gross Combination Weight Rating (GCWR); Definition AGENCY... combination weight rating'' (GCWR) in our regulations. The definition currently prescribes how the GCWR is... comment, if submitted on behalf of an association, business, labor union, etc.). You may review a Privacy...

  1. 77 FR 65497 - Gross Combination Weight Rating (GCWR); Definition

    Science.gov (United States)

    2012-10-29

    ... [Docket No. FMCSA-2012-0156] RIN 2126-AB53 Gross Combination Weight Rating (GCWR); Definition AGENCY... combination weight rating'' (GCWR) in 49 CFR parts 383 and 390. The DFR would have taken effect on October 26... submitted on behalf of an association, business, labor union, etc.). You may review a Privacy Act notice...

  2. Monopol suretab kohaliku loomakasvataja / Oleg Gross ; interv . Illar Mõttus

    Index Scriptorium Estoniae

    Gross, Oleg, 1952-

    2005-01-01

    Väike-Maarja jäätmetehase monopoolse seisundi vastu sõna võtnud OG Elektra omanik Oleg Gross on kindel, et jäätmetehasega suretatakse kohalikud väiksemad lihatootjad välja. Kommenteerivad talupidaja Jüri Järvet ja Rakvere Lihakombinaadi direktor Olle Horm

  3. casual relationship between gross domestic saving and economic

    African Journals Online (AJOL)

    TOSHIBA

    private saving has both direct and indirect effects on economic growth. ... sector have a bigger impact on GDP than gross domestic savings. ... Development economists have been concerned for decades about the crucial role of ..... higher investment and higher economic growth is not supported by East African countries.

  4. Placental mesenchymal dysplasia: case report with gross and histological findings.

    Science.gov (United States)

    Toscano, Marcello Pecoraro; Schultz, Regina

    2014-01-01

    Placental mesenchymal dysplasia (PMD) is a rare placental disorder characterized by placental enlargement and areas of abnormal, enlarged, grape-like villi. This condition may resemble a partial hydatidiform mole and may occur associated with Beckwith-Wiedemann syndrome (BWS) or in phenotypically normal fetuses. There were 110 cases reported so far. We describe one case with typical gross and microscopic placental lesions.

  5. Placental mesenchymal dysplasia: case report with gross and histological findings

    OpenAIRE

    Marcello Pecoraro Toscano; Regina Schultz

    2014-01-01

    Placental mesenchymal dysplasia (PMD) is a rare placental disorder characterized by placental enlargement and areas of abnormal, enlarged, grape-like villi. This condition may resemble a partial hydatidiform mole and may occur associated with Beckwith?Wiedemann syndrome (BWS) or in phenotypically normal fetuses. There were 110 cases reported so far. We describe one case with typical gross and microscopic placental lesions.

  6. Anomaly detection in real-time gross payment data

    NARCIS (Netherlands)

    Triepels, Ron; Daniels, Hennie; Heijmans, R.; Camp, Olivier; Filipe, Joaquim

    2017-01-01

    We discuss how an autoencoder can detect system-level anomalies in a real-time gross settlement system by reconstructing a set of liquidity vectors. A liquidity vector is an aggregated representation of the underlying payment network of a settlement system for a particular time interval.

  7. Comments on the research article by Gross et al. (2012)

    DEFF Research Database (Denmark)

    Guntur, Srinivas; Sørensen, Niels N.

    2014-01-01

    The purpose of this Letter to the Editor is to present a discussion on the physics of rotational augmentation based on existing work. One of the latest works by Gross et al. (2012) is highlighted here, and its conclusions are discussed. Based on the existing understanding of rotational augmentati...

  8. Lattice simulation of 2d Gross-Neveu-type models

    International Nuclear Information System (INIS)

    Limmer, M.; Gattringer, C.; Hermann, V.

    2006-01-01

    Full text: We discuss a Monte Carlo simulation of 2d Gross-Neveu-type models on the lattice. The four-Fermi interaction is written as a Gaussian integral with an auxiliary field and the fermion determinant is included by reweighting. We present results for bulk quantities and correlators and compare them to a simulation using a fermion-loop representation. (author)

  9. Potato production in Europe - a gross margin analysis

    DEFF Research Database (Denmark)

    Pedersen, Søren Marcus; Bizik, Jan; Costa, Luisa Dalla

    The purpose of this paper is to examine different cropping practices, cost structures and gross margins for producing conventional table potatoes in 6 different regions within the European Union: Czech Republic, Denmark, Italy, Poland, Portugal and Slovakia. Findings from this study show that pot...

  10. Gross theory of nuclear β-decay with shell effects

    International Nuclear Information System (INIS)

    Pabst, M.

    1979-01-01

    The present work tries to introduce shell effects selection rules into the gross theory systematically. Instead of an unbunched or bunched Fermigas spectrum a single-particle spectrum in the shell model with a Woods-Saxon potential is used. The knowledge of spin and parity of the levels allows us to introduce selection rules in an approximative way. (orig.)

  11. The effects of climatic factors on the occurrence and gross ...

    African Journals Online (AJOL)

    The bacterial agents of ovine and caprine pneumonia and associated gross pathological lesions were studied for a period of ten years (1985-1995). Bacteriological data were obtained from the necropsy report books of the Microbiology and Pathology Dagnostic units of the Department of Vetinary Pathology and ...

  12. Intrahepatic cholangiocarcinoma : gross appearance and corresponding pathologic and radiologic features

    International Nuclear Information System (INIS)

    Yoon, Kwon Ha; Kim, Chang Guhn; Lee, Moon Gyu; Ha, Hyun Kwon; Auh, Yong Ho; Lim, Jae Hoon

    1999-01-01

    To assess the clinical and pathologic features of each type of intrahepatic cholangiocarcinoma, which is divided into three types according to gross appearance, and to determine the efficacy of CT in detecting this tumor. The pathologic and CT features of 53 surgically proven cases of intrahepatic cholangio-carcinoma were reviewed. On the basis of their gross appearance, the tumors were divided into three types, as follows : mass forming (n=33), periductal infiltrating (n=6), and intraductal growth type (n=14). CT scans were analyzed for sensitivity of detection and correlation between a tumors appearance and its histopathology. The most common histopathologic feature of mass forming and periductal infiltrating type was tubular adenocarcinoma, while in the intraductal growth type, papillary adenocarcinoma (100%) was common. With regard to pattern of tumor spread, intrahepatic and lymph node metastasis were more common in the mass forming and periductal infiltrating type than in the intraductal growth type. CT findings including intrahepatic mass, ductal wall thickening or intraductal mass associated with segmental dilatation of intrahepataic bile ducts, corresponded with these morphologic types. This classification according to gross appearance is of considerable value when interpreting the pathologic features of intrahepatic cholangiocarcinoma. CT seems to be a useful modality for the detection of tumors and may be consistent with their gross morphologic findings

  13. Barn music at St Donat's castle / Philip Gross

    Index Scriptorium Estoniae

    Gross, Philip, 1952-

    2011-01-01

    Muusikafestivalist "Vale of Glamorgan", mis oli 2010. a. pühendatud Arvo Pärdile. Eesti kammermuusikaansambli Resonabilis kavas oli ka festivali tellimusel valminud uelsi helilooja Gareth Peredur Churchilli "Vocable", mille teksti kirjutas Philip Gross. Festivalikontsertide muljeid leiab Grossi luuletsüklis "Barn music" (avaldatud samas ajakirjanumbris, lk. 42-43)

  14. Fine and Gross Motor Ability in Males with ADHD

    Directory of Open Access Journals (Sweden)

    J Gordon Millichap

    2003-09-01

    Full Text Available Both fine and gross motor abilities were evaluated in 10-year-old males with attention deficit hyperactivity disorder (ADHD and compared to a group of control children at the School of Psychology, Curtin University of Technology, Perth, Australia.

  15. Energy use and gross margin analysis for sesame production in ...

    African Journals Online (AJOL)

    As the negative impacts of energy by-products affect the climate, the knowledge and efficient use of energy in crop production will minimise environmental problems and promote sustainable agriculture as an economic production system in Nigeria and else where. The aim of the study was to evaluate energy use and gross ...

  16. Gross and Histomorphological Assessment of the Oropharynx and ...

    African Journals Online (AJOL)

    The study investigated the morphology of the oropharynx and tongue of the guinea fowl using gross anatomical and histological techniques. The results showed that the mouth and pharynx of the guinea fowl lacked a definite line of demarcation, and so formed a common oropharyngeal cavity. The roof of the oropharynx ...

  17. School Physical Activity Programming and Gross Motor Skills in Children.

    Science.gov (United States)

    Burns, Ryan D; Fu, You; Hannon, James C; Brusseau, Timothy A

    2017-09-01

    We examined the effect of a comprehensive school physical activity program (CSPAP) on gross motor skills in children. Participants were 959 children (1st-6th grade; Mean age = 9.1 ± 1.5 years; 406 girls, 553 boys) recruited from 5 low-income schools receiving a year-long CSPAP intervention. Data were collected at the beginning of the school year and at a 36-week follow-up. Gross motor skills were assessed using the Test for Gross Motor Development (3rd ed.) (TGMD-3) instrument. Multi-level mixed effects models were employed to examine the effect of CSPAP on TGMD-3 scores, testing age and sex as effect modifiers and adjusting for clustering of observations within the data structure. There were statistically significant coefficients for time (β = 8.1, 95% CI [3.9, 12.3], p skills and ball skills sub-test scores. Children showed improved gross motor skill scores at the end of the 36-week CSPAP that were modified by age, as younger children displayed greater improvements in TGMD-3 scores compared to older children.

  18. Assessing Gross Motor Skills of Kosovar Preschool Children

    Science.gov (United States)

    Shala, Merita

    2009-01-01

    In the light of the new developments in preschool education in Kosovo, this study attempts to carry out an assessment of the development of gross motor skills of preschool children attending institutional education. The emphasis is on creating a set of tests to measure the motor attainments of these children by conducting assessments of the…

  19. Gross Motor Skill Acquisition in Adolescents with Down Syndrome

    Science.gov (United States)

    Meegan, Sarah; Maraj, Brian K. V.; Weeks, Daniel; Chua, Romeo

    2006-01-01

    The purpose of this study was to assess whether verbal-motor performances deficits exhibited by individuals with Down syndrome limited their ability to acquire gross motor skills when given visual and verbal instruction together and then transferred to either a visual or verbal instructional mode to reproduce the movement. Nine individuals with…

  20. A Study on Gross Motor Skills of Preschool Children

    Science.gov (United States)

    Wang, Joanne Hui-Tzu

    2004-01-01

    The purpose of this study was to investigate the effects of a creative movement program on gross motor skills of preschool children. Sixty children between the ages of 3 to 5 were drawn from the population of a preschool in Taichung, Taiwan. An experimental pretest-posttest control-group design was utilized. The children enrolled in the…

  1. Labelling of. beta. -endorphin (. beta. -END) and. beta. -lipotropin (. beta. -LPH) by /sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Deby-Dupont, G.; Joris, J.; Franchimont, P. (Universite de Liege (Belgique)); Reuter, A.M.; Vrindts-Gevaert, Y. (Institut des Radioelements, Fleurus (Belgique))

    1983-01-01

    5 ..mu..g of human ..beta..-endorphin were labelled with 2 mCi /sup 125/I by the chloramine T technique. After two gel filtrations on Sephadex G-15 and on Sephadex G-50 in phosphate buffer with EDTA, Trasylol and mercapto-ethanol, a pure tracer was obtained with a specific activity about 150 ..mu..Ci/..mu..g.Kept at + 4/sup 0/C, the tracer remained utilizable for 30 days without loss of immunoreactivity. The labelling with lactoperoxydase and the use of another gel filtration method (filtration on Aca 202) gave a /sup 125/I ..beta..-END tracer with the same immunoreactivity. The binding of this tracer to the antibody of an anti-..beta..-END antiserum diluted at 1/8000 was 32% with a non specific binding of 2%. 5 ..mu..g of human ..beta..-lipotropin were labelled with 0.5 mCi /sup 125/I by the lactoperoxydase method. After two gel filtrations on Sephadex G-25 and on Sephadex G-75 in phosphate buffer with EDTA, Trasylol and mercapto-ethanol, a pure tracer with a specific activity of 140 ..mu..Ci/..mu..g was obtained. It remained utilizable for 30 days when kept at + 4/sup 0/C. Gel filtration on Aca 202 did not give good purification, while gel filtration on Aca 54 was good but slower than on Sephadex G-75. The binding to antibody in absence of unlabelled ..beta..-LPH was 32% for an anti-..beta..-LPH antiserum diluted at 1/4000. The non specific binding was 2.5%.

  2. Plasma beta HCG determination

    International Nuclear Information System (INIS)

    Amaral, L.B.D.; Pinto, J.C.M.; Linhares, E.; Linhares, Estevao

    1981-01-01

    There are three important indications for the early diagnosis of pregnancy through the determination of the beta sub-unit of chorionic gonadotrophin using radioimmunoassay: 1) some patient's or doctor's anxiety to discover the problem; 2) when it will be necessary to employ diagnostic or treatment procedures susceptible to affect the ovum; and 3) in the differential diagnosis of amenorrhoea, uterine hemorrhage and abdominal tumors. Other user's are the diagnosis of missed absortion, and the diagnosis and follow-up of chrorioncarcinoma. The AA. studied 200 determinations of plasma beta-HCG, considering the main difficulties occuring in the clinical use of this relevant laboratory tool in actual Obstetrics. (author) [pt

  3. Relation between the 2{nu}{beta}{beta} and 0{nu}{beta}{beta} nuclear matrix elements

    Energy Technology Data Exchange (ETDEWEB)

    Vogel, Petr [Kellogg Radiation Laboratory, Caltech, Pasadena, CA 91125 (United States); Simkovic, Fedor [Department of Nuclear Physics and Biophysics, Comenius University, Mlynska dolina F1, SK-84248 Bratislava (Slovakia)

    2011-12-16

    A formal relation between the GT part of the nuclear matrix elements M{sub GT}{sup 0{nu}} of 0{nu}{beta}{beta} decay and the closure matrix elements M{sub cl}{sup 2{nu}} of 2{nu}{beta}{beta} decay is established. This relation is based on the integral representation of these quantities in terms of their dependence on the distance r between the two nucleons undergoing transformation. We also discuss the difficulties in determining the correct values of the closure 2{nu}{beta}{beta} decay matrix elements.

  4. Liquid scintillation, counting, and compositions

    International Nuclear Information System (INIS)

    Sena, E.A.; Tolbert, B.M.; Sutula, C.L.

    1975-01-01

    The emissions of radioactive isotopes in both aqueous and organic samples can be measured by liquid scintillation counting in micellar systems. The micellar systems are made up of scintillation solvent, scintillation solute and a mixture of surfactants, preferably at least one of which is relatively oil-soluble water-insoluble and another which is relatively water-soluble oil-insoluble

  5. Phase space quark counting rule

    International Nuclear Information System (INIS)

    Wei-gin, C.; Lo, S.

    1980-01-01

    A simple quark counting rule based on phase space consideration suggested before is used to fit all 39 recent experimental data points on inclusive reactions. Parameter free relations are found to agree with experiments. Excellent detail fits are obtained for 11 inclusive reactions

  6. Counting a Culture of Mealworms

    Science.gov (United States)

    Ashbrook, Peggy

    2007-01-01

    Math is not the only topic that will be discussed when young children are asked to care for and count "mealworms," a type of insect larvae (just as caterpillars are the babies of butterflies, these larvae are babies of beetles). The following activity can take place over two months as the beetles undergo metamorphosis from larvae to adults. As the…

  7. Counting problems for number rings

    NARCIS (Netherlands)

    Brakenhoff, Johannes Franciscus

    2009-01-01

    In this thesis we look at three counting problems connected to orders in number fields. First we study the probability that for a random polynomial f in Z[X] the ring Z[X]/f is the maximal order in Q[X]/f. Connected to this is the probability that a random polynomial has a squarefree

  8. On Counting the Rational Numbers

    Science.gov (United States)

    Almada, Carlos

    2010-01-01

    In this study, we show how to construct a function from the set N of natural numbers that explicitly counts the set Q[superscript +] of all positive rational numbers using a very intuitive approach. The function has the appeal of Cantor's function and it has the advantage that any high school student can understand the main idea at a glance…

  9. Logistic regression for dichotomized counts.

    Science.gov (United States)

    Preisser, John S; Das, Kalyan; Benecha, Habtamu; Stamm, John W

    2016-12-01

    Sometimes there is interest in a dichotomized outcome indicating whether a count variable is positive or zero. Under this scenario, the application of ordinary logistic regression may result in efficiency loss, which is quantifiable under an assumed model for the counts. In such situations, a shared-parameter hurdle model is investigated for more efficient estimation of regression parameters relating to overall effects of covariates on the dichotomous outcome, while handling count data with many zeroes. One model part provides a logistic regression containing marginal log odds ratio effects of primary interest, while an ancillary model part describes the mean count of a Poisson or negative binomial process in terms of nuisance regression parameters. Asymptotic efficiency of the logistic model parameter estimators of the two-part models is evaluated with respect to ordinary logistic regression. Simulations are used to assess the properties of the models with respect to power and Type I error, the latter investigated under both misspecified and correctly specified models. The methods are applied to data from a randomized clinical trial of three toothpaste formulations to prevent incident dental caries in a large population of Scottish schoolchildren. © The Author(s) 2014.

  10. Vote Counting as Mathematical Proof

    DEFF Research Database (Denmark)

    Schürmann, Carsten; Pattinson, Dirk

    2015-01-01

    then consists of a sequence (or tree) of rule applications and provides an independently checkable certificate of the validity of the result. This reduces the need to trust, or otherwise verify, the correctness of the vote counting software once the certificate has been validated. Using a rule...

  11. Counting SET-free sets

    OpenAIRE

    Harman, Nate

    2016-01-01

    We consider the following counting problem related to the card game SET: How many $k$-element SET-free sets are there in an $n$-dimensional SET deck? Through a series of algebraic reformulations and reinterpretations, we show the answer to this question satisfies two polynomiality conditions.

  12. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    OpenAIRE

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms, 3 bulk milk samples were collected at intervals of 2 wk. The samples were cultured for SPC, coliform count, and staphylococcal count and for the presence of Staphylococcus aureus. Furthermore, SCC ...

  13. Counting efficiency for liquid scintillator systems with a single multiplier phototube; Eficiencia de recuento en espectrometros de centelleo con un solo fotomultiplicador

    Energy Technology Data Exchange (ETDEWEB)

    Grau Malonda, A; Garcia-Torano, E

    1984-07-01

    In this paper counting efficiency as a function of a free parameter (the figure of merit) has been computed. The results are applicable to liquid scintillator systems with a single multiplier phototube. Tables of counting efficiency for 62 pure beta emitters are given for figures of merit in the range 0.25 to 50. (Author) 16 refs.

  14. Induced nuclear beta decay

    International Nuclear Information System (INIS)

    Reiss, H.R.

    1986-01-01

    Certain nuclear beta decay transitions normally inhibited by angular momentum or parity considerations can be induced to occur by the application of an electromagnetic field. Such decays can be useful in the controlled production of power, and in fission waste disposal

  15. Trichoderma .beta.-glucosidase

    Science.gov (United States)

    Dunn-Coleman, Nigel; Goedegebuur, Frits; Ward, Michael; Yao, Jian

    2006-01-03

    The present invention provides a novel .beta.-glucosidase nucleic acid sequence, designated bgl3, and the corresponding BGL3 amino acid sequence. The invention also provides expression vectors and host cells comprising a nucleic acid sequence encoding BGL3, recombinant BGL3 proteins and methods for producing the same.

  16. Applied Beta Dosimetry

    International Nuclear Information System (INIS)

    Rich, B.L.

    1986-01-01

    Measurements of beta and/or nonpenetrating exposure results is complicated and past techniques and capabilities have resulted in significant inaccuracies in recorded results. Current developments have resulted in increased capabilities which make the results more accurate and should result in less total exposure to the work force. Continued development of works in progress should provide equivalent future improvements

  17. Beta thalassemia - a review

    Directory of Open Access Journals (Sweden)

    R Jha

    2014-09-01

    Full Text Available Thalassemia is a globin gene disorder that results in a diminished rate of synthesis of one or more of the globin chains. About 1.5% of the global population (80 to 90 million people are carriers of beta Thalassemia. More than 200 mutations are described in beta thalassemia. However not all mutations are common in different ethnic groups. The only effective way to reduce burden of thalassemia is to prevent birth of homozygotes. Diagnosis of beta thalassemia can be done by fetal DNA analysis for molecular defects of beta thalassemia or by fetal blood analysis. Hematopoietic stem cell transplantation is the only available curative approach for Thalassemia. Many patients with thalassemia in underdeveloped nations die in childhood or adolescence. Programs that provide acceptable care, including transfusion of safe blood and supportive therapy including chelation must be established.DOI: http://dx.doi.org/10.3126/jpn.v4i8.11609 Journal of Pathology of Nepal; Vol.4,No. 8 (2014 663-671

  18. Double Beta Decay Experiments

    International Nuclear Information System (INIS)

    Piepke, A.

    2005-01-01

    The experimental observation of neutrino oscillations and thus neutrino mass and mixing gives a first hint at new particle physics. The absolute values of the neutrino mass and the properties of neutrinos under CP-conjugation remain unknown. The experimental investigation of the nuclear double beta decay is one of the key techniques for solving these open problems

  19. Gross Domestic Savings and Gross Capital: what Matters to Their Formation in an Era of Economic Recession in Nigeria?

    Directory of Open Access Journals (Sweden)

    Success Abusomwan

    2017-09-01

    Full Text Available The objective of this study is to empirically investigate the long run and short run dynamic impact of interest rate and output on gross domestic savings and gross capital formation in Nigeria. Literatures, both theoretical and empirical, suggest that the rate of interest and output are the key factors influencing savings and investments. A review of factors influencing interest rates and output in Nigeria is necessitated by the recent economic downturns in Nigeria that has resulted in tight monetary policy which some commentators regard as inimical to growth. Employing Ordinary Least Squares, Co-integration, Error Correction Mechanism and Granger Causality econometric techniques on a data spanning 1981 to 2014 of the Nigerian economy sourced from the World Development Index, it was found that changes in output explains the long run and short run dynamic behaviour of gross domestic savings and gross capital formation which were used as proxies for savings and investment respectively. Whereas, a bi-causality was established between output and investment, causality flowed from output to savings in Nigeria. The research also found that interest rate is not a significant determinant of savings and investment in Nigeria in both long run and short run. It is therefore recommended that to enhance investment in a period of economic downturn in Nigeria, aggregate demand should be boosted to enhance output through vigorous pursuit of fiscal policy while implementing contractionary monetary policy to address inflationary pressures created by the increase in demand. Domestic savings will improve and gross capital formation will be sustained.

  20. Beta cell adaptation in pregnancy

    DEFF Research Database (Denmark)

    Nielsen, Jens Høiriis

    2016-01-01

    Pregnancy is associated with a compensatory increase in beta cell mass. It is well established that somatolactogenic hormones contribute to the expansion both indirectly by their insulin antagonistic effects and directly by their mitogenic effects on the beta cells via receptors for prolactin...... and growth hormone expressed in rodent beta cells. However, the beta cell expansion in human pregnancy seems to occur by neogenesis of beta cells from putative progenitor cells rather than by proliferation of existing beta cells. Claes Hellerström has pioneered the research on beta cell growth for decades...... in the expansion of the beta cell mass in human pregnancy, and the relative roles of endocrine factors and nutrients....

  1. Energy response of detectors to alpha/beta particles and compatibility of the equivalent factors

    International Nuclear Information System (INIS)

    Lin Bingxing; Li Guangxian; Lin Lixiong

    2011-01-01

    By measuring detect efficiency and equivalent factors of alpha/beta radiation with different energies on three types of detectors, this paper compares compatibility of their equivalent factors and discusses applicability of detectors to measuring total alpha/beta radiation. The result shows the relationship between efficiency of alpha/beta radiation and their energies on 3 types of detectors, such as scintillation and proportional and semiconductor counters, are overall identical. Alpha count efficiency display exponential relation with alpha-particle energy. While beta count efficiency display logarithm relation with beta-particle energy, but the curves appears deflection at low energy. Comparison test of energy response also shows that alpha and beta equivalent factors of scintillation and proportional counters have a good compatibility, and alpha equivalent factors of the semiconductor counters are in good agreement with those of the above two types of counters, but beta equivalent factors have obvious difference, or equivalent factors of low energy beta-particle are lower than those of other detectors. So, the semiconductor counter can not be used for measuring total radioactivity or for the measurements for the purpose of food safety. (authors)

  2. Spectrum library concept and pulse shape analysis in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Kaihola, L [Wallac Oy, Turku (Finland)

    1997-03-01

    Wallac introduced in 1990 a new absolute liquid scintillation counting (LSC) method, Digital Overlay Technique (DOT) to correct for quench. This method allows quantization of multilabel samples by referring to library spectra which are generated against chemical and color quench indices at the factory. The libraries can further be expanded to any beta emitter by user with a method called fine tuning, which can be carried out even with a single sample. Spectrum libraries are created over the whole spectrum range of the radionuclide and allow automatic identification of a single label beta emitting radionuclide, called Easy Count method. Another improvement in LSC is commercial introduction of Pulse Shape Analysis (PSA) in 1986 by Wallac. This method recognizes alpha particle decay by pulse shape and leads to excellent sensitivity in alpha counting because most of the background signal in LSC comprises of short or beta like pulses. PSA detects alpha events in the presence of high excess of beta activity over alphas, up to a ratio 100000 to 1. (orig.)

  3. Misleading Betas: An Educational Example

    Science.gov (United States)

    Chong, James; Halcoussis, Dennis; Phillips, G. Michael

    2012-01-01

    The dual-beta model is a generalization of the CAPM model. In the dual-beta model, separate beta estimates are provided for up-market and down-market days. This paper uses the historical "Anscombe quartet" results which illustrated how very different datasets can produce the same regression coefficients to motivate a discussion of the…

  4. Theory of photoelectron counting statistics

    International Nuclear Information System (INIS)

    Blake, J.

    1980-01-01

    The purpose of the present essay is to provide a detailed analysis of those theoretical aspects of photoelectron counting which are capable of experimental verification. Most of our interest is in the physical phenomena themselves, while part is in the mathematical techniques. Many of the mathematical methods used in the analysis of the photoelectron counting problem are generally unfamiliar to physicists interested in the subject. For this reason we have developed the essay in such a fashion that, although primary interest is focused on the physical phenomena, we have also taken pains to carry out enough of the analysis so that the reader can follow the main details. We have chosen to present a consistently quantum mechanical version of the subject, in that we follow the Glauber theory throughout. (orig./WL)

  5. Bayesian Kernel Mixtures for Counts.

    Science.gov (United States)

    Canale, Antonio; Dunson, David B

    2011-12-01

    Although Bayesian nonparametric mixture models for continuous data are well developed, there is a limited literature on related approaches for count data. A common strategy is to use a mixture of Poissons, which unfortunately is quite restrictive in not accounting for distributions having variance less than the mean. Other approaches include mixing multinomials, which requires finite support, and using a Dirichlet process prior with a Poisson base measure, which does not allow smooth deviations from the Poisson. As a broad class of alternative models, we propose to use nonparametric mixtures of rounded continuous kernels. An efficient Gibbs sampler is developed for posterior computation, and a simulation study is performed to assess performance. Focusing on the rounded Gaussian case, we generalize the modeling framework to account for multivariate count data, joint modeling with continuous and categorical variables, and other complications. The methods are illustrated through applications to a developmental toxicity study and marketing data. This article has supplementary material online.

  6. Sensitivity of NEXT-100 to neutrinoless double beta decay

    CERN Document Server

    Martín-Albo, J.; Ferrario, P.; Nebot-Guinot, M.; Gómez-Cadenas, J.J.; Álvarez, V.; Azevedo, C.D.R.; Borges, F.I.G.; Cárcel, S.; Cebrián, S.; Cervera, A.; Conde, C.A.N.; Díaz, J.; Diesburg, M.; Esteve, R.; Fernandes, L.M.P.; Ferreira, A.L.; Freitas, E.D.C.; Gehman, V.M.; Goldschmidt, A.; González-Díaz, D.; Gutiérrez, R.M.; Henriques, C.A.O.; Hernando Morata, J.A.; Labarga, L.; Laing, A.; Lebrun, P.; Liubarsky, I.; López-March, N.; Lorca, D.; Losada, M.; Martínez-Lema, G.; Martínez, A.; Miller, T.; Monrabal, F.; Monserrate, M.; Monteiro, C.M.B.; Mora, F.J.; Moutinho, L.M.; Novella, P.; Nygren, D.; Para, A.; Perez, J.; Perez Aparicio, J.L.; Querol, M.; Renner, J.; Ripoll, L.; Rodríguez, J.; Santos, F.P.; dos Santos, J.M.F.; Serra, L.; Shuman, D.; Simón, A.; Sofka, C.; Sorel, M.; Stiegler, T.; Toledo, J.F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J.F.C.A.; Villar, J.A.; Webb, R.; White, J.T.; Yahlali, N.; Yepes-Ramírez, H.; Hauptman, J.

    2016-01-01

    NEXT-100 is an electroluminescent high-pressure xenon gas time projection chamber that will search for the neutrinoless double beta decay of Xe-136. The detector possesses two features of great value in neutrinoless double beta decay searches: very good energy resolution (better than 1% FWHM at the Q value of Xe-136) and track reconstruction for the discrimination of signal and background events. This combination results in excellent sensitivity, as discussed in this paper. Detailed Monte Carlo detector simulations and material-screening measurements predict a background rate for NEXT-100 of at most 0.0004 counts/(keV kg yr). Accordingly, the detector will reach a sensitivity to the neutrinoless double beta decay half-life of 6.E25 years after running for 3 effective years.

  7. Card counting in continuous time

    OpenAIRE

    Andersson, Patrik

    2012-01-01

    We consider the problem of finding an optimal betting strategy for a house-banked casino card game that is played for several coups before reshuffling. The sampling without replacement makes it possible to take advantage of the changes in the expected value as the deck is depleted, making large bets when the game is advantageous. Using such a strategy, which is easy to implement, is known as card counting. We consider the case of a large number of decks, making an approximat...

  8. Gross-Pitaevski map as a chaotic dynamical system.

    Science.gov (United States)

    Guarneri, Italo

    2017-03-01

    The Gross-Pitaevski map is a discrete time, split-operator version of the Gross-Pitaevski dynamics in the circle, for which exponential instability has been recently reported. Here it is studied as a classical dynamical system in its own right. A systematic analysis of Lyapunov exponents exposes strongly chaotic behavior. Exponential growth of energy is then shown to be a direct consequence of rotational invariance and for stationary solutions the full spectrum of Lyapunov exponents is analytically computed. The present analysis includes the "resonant" case, when the free rotation period is commensurate to 2π, and the map has countably many constants of the motion. Except for lowest-order resonances, this case exhibits an integrable-chaotic transition.

  9. Vast Portfolio Selection with Gross-exposure Constraints().

    Science.gov (United States)

    Fan, Jianqing; Zhang, Jingjin; Yu, Ke

    2012-01-01

    We introduce the large portfolio selection using gross-exposure constraints. We show that with gross-exposure constraint the empirically selected optimal portfolios based on estimated covariance matrices have similar performance to the theoretical optimal ones and there is no error accumulation effect from estimation of vast covariance matrices. This gives theoretical justification to the empirical results in Jagannathan and Ma (2003). We also show that the no-short-sale portfolio can be improved by allowing some short positions. The applications to portfolio selection, tracking, and improvements are also addressed. The utility of our new approach is illustrated by simulation and empirical studies on the 100 Fama-French industrial portfolios and the 600 stocks randomly selected from Russell 3000.

  10. Vast Portfolio Selection with Gross-exposure Constraints*

    Science.gov (United States)

    Fan, Jianqing; Zhang, Jingjin; Yu, Ke

    2012-01-01

    We introduce the large portfolio selection using gross-exposure constraints. We show that with gross-exposure constraint the empirically selected optimal portfolios based on estimated covariance matrices have similar performance to the theoretical optimal ones and there is no error accumulation effect from estimation of vast covariance matrices. This gives theoretical justification to the empirical results in Jagannathan and Ma (2003). We also show that the no-short-sale portfolio can be improved by allowing some short positions. The applications to portfolio selection, tracking, and improvements are also addressed. The utility of our new approach is illustrated by simulation and empirical studies on the 100 Fama-French industrial portfolios and the 600 stocks randomly selected from Russell 3000. PMID:23293404

  11. GLOBALIZATION AND GROSS DOMESTIC PRODUCT CONSTRUCTION IN ASEAN

    Directory of Open Access Journals (Sweden)

    Muhammad Sri Wahyudi Suliswanto

    2011-09-01

    Full Text Available There is no more doubt about the importance of economic growth, which can be calculated fromGross Domestic Product (GDP. This research analyzes the role of globalization on GDP inASEAN-5 by estimating panel data. It uses a fixed effect approach to accommodate various characteristicsin the countries. To accommodate such variation, it assumes that the intercepts variesacross these countries, while the slopes remain similar. Based on the estimation result, it suggeststhat net export and foreign direct investment represent the globalization process. Both have positiveand significant influences on GDP in the corresponding countries.Keywords: Globalization, international trade, foreign direct investment, gross domestic productJEL classification numbers: E01, F51, F43

  12. The San Andreas fault experiment. [gross tectonic plates relative velocity

    Science.gov (United States)

    Smith, D. E.; Vonbun, F. O.

    1973-01-01

    A plan was developed during 1971 to determine gross tectonic plate motions along the San Andreas Fault System in California. Knowledge of the gross motion along the total fault system is an essential component in the construction of realistic deformation models of fault regions. Such mathematical models will be used in the future for studies which will eventually lead to prediction of major earthquakes. The main purpose of the experiment described is the determination of the relative velocity of the North American and the Pacific Plates. This motion being so extremely small, cannot be measured directly but can be deduced from distance measurements between points on opposite sites of the plate boundary taken over a number of years.

  13. Jatropha curcas – Analysis of Gross Calorific Value

    Directory of Open Access Journals (Sweden)

    Juraj Ružbarský

    2014-01-01

    Full Text Available In recent years biofuels have obtained a considerable interest, due to the implementation of ruling and gradual replacement of fossil fuels. One of production steps at gaining the oil is a pressing process. Wastes come into being from this process. These wastes are used as feed, fertilizer prospectively as fuel. A contemporary scientific literature pays attention namely to one of prospective produces which is a produce of the tropical and subtropical zones Jatropa curcas. Tests were performed at Jatropha Curcas seeds of a brown colour (that means gnaw. The aim of a research is an analysis of Jatropa curcas seed from the utilization point of view of the gross calorific value. The basic instrument to evaluate the gross calorific value of each variant of the experiment was a calorimeter PARR 6200 and digital scales for accurate laboratory weighing.

  14. Monitoring Milk Somatic Cell Counts

    Directory of Open Access Journals (Sweden)

    Gheorghe Şteţca

    2014-11-01

    Full Text Available The presence of somatic cells in milk is a widely disputed issue in milk production sector. The somatic cell counts in raw milk are a marker for the specific cow diseases such as mastitis or swollen udder. The high level of somatic cells causes physical and chemical changes to milk composition and nutritional value, and as well to milk products. Also, the mastitic milk is not proper for human consumption due to its contribution to spreading of certain diseases and food poisoning. According to these effects, EU Regulations established the maximum threshold of admitted somatic cells in raw milk to 400000 cells / mL starting with 2014. The purpose of this study was carried out in order to examine the raw milk samples provided from small farms, industrial type farms and milk processing units. There are several ways to count somatic cells in milk but the reference accepted method is the microscopic method described by the SR EN ISO 13366-1/2008. Generally samples registered values in accordance with the admissible limit. By periodical monitoring of the somatic cell count, certain technological process issues are being avoided and consumer’s health ensured.

  15. Interaction with beta-arrestin determines the difference in internalization behavor between beta1- and beta2-adrenergic receptors.

    Science.gov (United States)

    Shiina, T; Kawasaki, A; Nagao, T; Kurose, H

    2000-09-15

    The beta(1)-adrenergic receptor (beta(1)AR) shows the resistance to agonist-induced internalization. As beta-arrestin is important for internalization, we examine the interaction of beta-arrestin with beta(1)AR with three different methods: intracellular trafficking of beta-arrestin, binding of in vitro translated beta-arrestin to intracellular domains of beta(1)- and beta(2)ARs, and inhibition of betaAR-stimulated adenylyl cyclase activities by beta-arrestin. The green fluorescent protein-tagged beta-arrestin 2 translocates to and stays at the plasma membrane by beta(2)AR stimulation. Although green fluorescent protein-tagged beta-arrestin 2 also translocates to the plasma membrane, it returns to the cytoplasm 10-30 min after beta(1)AR stimulation. The binding of in vitro translated beta-arrestin 1 and beta-arrestin 2 to the third intracellular loop and the carboxyl tail of beta(1)AR is lower than that of beta(2)AR. The fusion protein of beta-arrestin 1 with glutathione S-transferase inhibits the beta(1)- and beta(2)AR-stimulated adenylyl cyclase activities, although inhibition of the beta(1)AR-stimulated activity requires a higher concentration of the fusion protein than that of the beta(2)AR-stimulated activity. These results suggest that weak interaction of beta(1)AR with beta-arrestins explains the resistance to agonist-induced internalization. This is further supported by the finding that beta-arrestin can induce internalization of beta(1)AR when beta-arrestin 1 does not dissociate from beta(1)AR by fusing to the carboxyl tail of beta(1)AR.

  16. Unitarity violation in noninteger dimensional Gross-Neveu-Yukawa model

    Science.gov (United States)

    Ji, Yao; Kelly, Michael

    2018-05-01

    We construct an explicit example of unitarity violation in fermionic quantum field theories in noninteger dimensions. We study the two-point correlation function of four-fermion operators. We compute the one-loop anomalous dimensions of these operators in the Gross-Neveu-Yukawa model. We find that at one-loop order, the four-fermion operators split into three classes with one class having negative norms. This implies that the theory violates unitarity, following the definition in Ref. [1].

  17. Gross efficiency and energy expenditure in kayak ergometer exercise.

    Science.gov (United States)

    Gomes, B B; Mourão, L; Massart, A; Figueiredo, P; Vilas-Boas, J P; Santos, A M C; Fernandes, R J

    2012-08-01

    We purposed to study energy expenditure, power output and gross efficiency during kayak ergometer exercise in 12 elite sprint kayakers. 6 males (age 24.2±4.8 years, height 180.4±4.8 cm, body mass 79.7±8.5 kg) and 6 females (age 24.3±4.5 years, height 164.5±3.9 cm, body mass 65.4±3.5 kg), performed an incremental intermittent protocol on kayak ergometer with VO2 and blood lactate concentration assessment, a non-linear increase between power output and energy expenditure being observed. Paddling power output, energy expenditure and gross efficiency corresponding to VO2max averaged 199.92±50.41 W, 75.27±6.30 ml.kg - 1.min - 1, and 10.10±1.08%. Male kayakers presented higher VO2max, power output and gross efficiency at the VO2max, and lower heart rate and maximal lactate concentration than females, but no differences were found between genders regarding energy expenditure at VO2max. Aerobic and anaerobic components of energy expenditure evidenced a significant contribution of anaerobic energy sources in sprint kayak performance. Results also suggested the dependence of the gross efficiency on the changes in the amount of the aerobic and anaerobic contributions, at heavy and severe intensities. The inter-individual variance of the relationship between energy expenditure and the corresponding paddling power output revealed a relevant tracking for females (FDγ=0.73±0.06), conversely to the male group (FDγ=0.27±0.08), supporting that some male kayakers are more skilled in some paddling intensities than others. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Gross alfa activity measurement in water from the Agueda river

    International Nuclear Information System (INIS)

    Fernandez, F.; Figueroa, C.F.; Gomez, J.M.G.; Lozano, J.C.

    1987-01-01

    Gross α activity has been measured in water from the Agueda river, in the province of Salamanca (Spain), covering about 45 km around the uranium mine Fe. The activity has been found to be negligeable above the mine, and average values range from 0.13Bq/λ just after the mine to 0,05 Bq/λ 22 km below. (author) 9 refs

  19. Determination of gross plasma equilibrium from magnetic multipoles

    Energy Technology Data Exchange (ETDEWEB)

    Kessel, C.E.

    1986-05-01

    A new approximate technique to determine the gross plasma equilibrium parameters, major radius, minor radius, elongation and triangularity for an up-down symmetric plasma is developed. It is based on a multipole representation of the externally applied poloidal magnetic field, relating specific terms to the equilibrium parameters. The technique shows reasonable agreement with free boundary MHD equilibrium results. The method is useful in dynamic simulation and control studies.

  20. Determination of gross plasma equilibrium from magnetic multipoles

    International Nuclear Information System (INIS)

    Kessel, C.E.

    1986-05-01

    A new approximate technique to determine the gross plasma equilibrium parameters, major radius, minor radius, elongation and triangularity for an up-down symmetric plasma is developed. It is based on a multipole representation of the externally applied poloidal magnetic field, relating specific terms to the equilibrium parameters. The technique shows reasonable agreement with free boundary MHD equilibrium results. The method is useful in dynamic simulation and control studies

  1. Placental mesenchymal dysplasia: case report with gross and histological findings

    Directory of Open Access Journals (Sweden)

    Marcello Pecoraro Toscano

    2014-12-01

    Full Text Available Placental mesenchymal dysplasia (PMD is a rare placental disorder characterized by placental enlargement and areas of abnormal, enlarged, grape-like villi. This condition may resemble a partial hydatidiform mole and may occur associated with Beckwith–Wiedemann syndrome (BWS or in phenotypically normal fetuses. There were 110 cases reported so far. We describe one case with typical gross and microscopic placental lesions.

  2. Recent status of the studies of nuclear masses and {beta}-decay

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Masami [Waseda Univ., Tokyo (Japan). Advanced Research Center for Science and Engineering

    1996-05-01

    The recent status of the above studies was explained, especially, nuclear masses were described from the aspect of probability theory and that of {beta}-decay suggested that the first forbidden transition was hindered between the ground states. We have to study various systematics in order to know the mass surface, Way-Yamada-Matumoto type systematics is better to check the experimental nuclear masses. The gross theory is very useful to understand the general aspect of {beta}-decay. The understanding method of mass surface, systematic check of mass and hindrance of the first forbidden transition at rank 1 were explained. (S.Y.)

  3. Improvements of mass formula and β-decay gross theory

    International Nuclear Information System (INIS)

    Tachibana, Takahiro

    1987-01-01

    The nuclear mass greatly decreases when the number of protons Z and neutrons N is simultaneously equal to a magic number (mutual support of magicities). The mass also tends to decrease due to deformation as both N and Z are away from the magic numbers (mutual support of deformations). These two effects are introduced to a nuclear mass formula containing a constant-type shell term to derive a new formula. The mass excess is expressed by a sum of three parts, i.e. gross part, even-odd part and shell part. The gross part, which represents the general nature, consists of two rest mass terms and a coulomb term. The even-odd part is of a typical form with a correction term. The shell part consists of a proton shell term, neutron shell term, third term expressing the two mutual support effects, and fourth term representing a decrease in coulomb energy due to deformation of the nucleus. The improvements made in the β-decay gross theory are associated with the single particle intensity function D 0 GT (E,ε). They are intended for: (1) reproducing the peak that accounts for about a half of the Gamow-Teller intensity, which has recently been found in (p,n) reactions at energies above the isobaric analogue state and (2) explaining the other half by an exponential-type D 0 GT (E,ε). (Nogami, K.)

  4. Background reduction and noise discrimination in the proportional counting of tritium using pulse-shape analysis

    Energy Technology Data Exchange (ETDEWEB)

    Hochel, R C; Hayes, D W [Du Pont de Nemours (E.I.) and Co., Aiken, S.C. (USA). Savannah River Lab.

    1975-12-01

    A pulse-shape analysis (PSA) unit of commercial design has been incorporated into a proportional counting system to determine the effectiveness of pulse-shape discrimination in increasing the sensitivity of tritium counting. It was found that a quantitative determination of tritium could be obtained directly from the PSA time spectrum eliminating the need for beta-ray energy selection used in the pulse-shape discrimination (PSD) technique. The performance of the proportional counting system was tested using the PSA unit and anticoincidence shielding, both singly and combined, under several types of background. A background reduction factor of 169 was obtained from the combined PSA-anticoincidence system with only a 2% loss in tritium counting efficiency. The PSA method was also found to offer significant reductions in noise background.

  5. Background reduction and noise discrimination in the proportional counting of tritium using pulse-shape analysis

    International Nuclear Information System (INIS)

    Hochel, R.C.; Hayes, D.W.

    1975-01-01

    A pulse-shape analysis (PSA) unit of commercial design has been incorporated into a proportional counting system to determine the effectiveness of pulse-shape discrimination in increasing the sensitivity of tritium counting. It was found that a quantitative determination of tritium could be obtained directly from the PSA time spectrum eliminating the need for beta-ray energy selection used in the pulse-shape discrimination (PSD) technique. The performance of the proportional counting system was tested using the PSA unit and anticoincidence shielding, both singly and combined, under several types of background. A background reduction factor of 169 was obtained from the combined PSA-anticoincidence system with only a 2% loss in tritium counting efficiency. The PSA method was also found to offer significant reductions in noise background. (Auth.)

  6. Low-beta investment strategies

    OpenAIRE

    Korn, Olaf; Kuntz, Laura-Chloé

    2015-01-01

    This paper investigates investment strategies that exploit the low-beta anomaly. Although the notion of buying low-beta stocks and selling high-beta stocks is natural, a choice is necessary with respect to the relative weighting of high-beta stocks and low-beta stocks in the investment portfolio. Our empirical results for US large-cap stocks show that this choice is very important for the risk-return characteristics of the resulting portfolios and their sensitivities to common risk factors. W...

  7. Neutrophil beta-2 microglobulin: an inflammatory mediator

    DEFF Research Database (Denmark)

    Bjerrum, O W; Nissen, Mogens Holst; Borregaard, N

    1990-01-01

    Beta-2 microglobulin (beta 2m) constitutes the light invariant chain of HLA class I antigen, and is a constituent of mobilizable compartments of neutrophils. Two forms of beta 2m exist: native beta 2m and proteolytically modified beta 2m (Des-Lys58-beta 2m), which shows alpha mobility in crossed ...

  8. Trends in physical activity, health-related fitness, and gross motor skills in children during a two-year comprehensive school physical activity program.

    Science.gov (United States)

    Brusseau, Timothy A; Hannon, James C; Fu, You; Fang, Yi; Nam, Kahyun; Goodrum, Sara; Burns, Ryan D

    2018-01-06

    The purpose of this study was to examine the trends in school-day step counts, health-related fitness, and gross motor skills during a two-year Comprehensive School Physical Activity Program (CSPAP) in children. Longitudinal trend analysis. Participants were a sample of children (N=240; mean age=7.9±1.2 years; 125 girls, 115 boys) enrolled in five low-income schools. Outcome variables consisted of school day step counts, Body Mass Index (BMI), estimated VO 2 Peak , and gross motor skill scores assessed using the Test of Gross Motor Development-3rd Edition (TGMD-3). Measures were collected over a two-year CSPAP including a baseline and several follow-up time-points. Multi-level mixed effects models were employed to examine time trends on each continuous outcome variable. Markov-chain transition models were employed to examine time trends for derived binary variables for school day steps, BMI, and estimated VO 2 Peak . There were statistically significant time coefficients for estimated VO 2 Peak (b=1.10mL/kg/min, 95% C.I. [0.35mL/kg/min-2.53mL/kg/min], p=0.009) and TGMD-3 scores (b=7.8, 95% C.I. [6.2-9.3], p<0.001). There were no significant changes over time for school-day step counts or BMI. Boys had greater change in odds of achieving a step count associating with 30min of school day MVPA (OR=1.25, 95% C.I. [1.02-1.48], p=0.044). A two-year CSPAP related to increases in cardio-respiratory endurance and TGMD-3 scores. School day steps and BMI were primarily stable across the two-year intervention. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Beta and muon decays

    International Nuclear Information System (INIS)

    Galindo, A.; Pascual, P.

    1967-01-01

    These notes represent a series of lectures delivered by the authors in the Junta de Energia Nuclear, during the Spring term of 1965. They were devoted to graduate students interested in the Theory of Elementary Particles. Special emphasis was focussed into the computational problems. Chapter I is a review of basic principles (Dirac equation, transition probabilities, final state interactions.) which will be needed later. In Chapter II the four-fermion punctual Interaction is discussed, Chapter III is devoted to the study of beta-decay; the main emphasis is given to the deduction of the formulae corresponding to electron-antineutrino correlation, electron energy spectrum, lifetimes, asymmetry of electrons emitted from polarized nuclei, electron and neutrino polarization and time reversal invariance in beta decay. In Chapter IV we deal with the decay of polarized muons with radiative corrections. Chapter V is devoted to an introduction to C.V.C. theory. (Author)

  10. Beta-thalassemia

    Directory of Open Access Journals (Sweden)

    Origa Raffaella

    2010-05-01

    Full Text Available Abstract Beta-thalassemias are a group of hereditary blood disorders characterized by anomalies in the synthesis of the beta chains of hemoglobin resulting in variable phenotypes ranging from severe anemia to clinically asymptomatic individuals. The total annual incidence of symptomatic individuals is estimated at 1 in 100,000 throughout the world and 1 in 10,000 people in the European Union. Three main forms have been described: thalassemia major, thalassemia intermedia and thalassemia minor. Individuals with thalassemia major usually present within the first two years of life with severe anemia, requiring regular red blood cell (RBC transfusions. Findings in untreated or poorly transfused individuals with thalassemia major, as seen in some developing countries, are growth retardation, pallor, jaundice, poor musculature, hepatosplenomegaly, leg ulcers, development of masses from extramedullary hematopoiesis, and skeletal changes that result from expansion of the bone marrow. Regular transfusion therapy leads to iron overload-related complications including endocrine complication (growth retardation, failure of sexual maturation, diabetes mellitus, and insufficiency of the parathyroid, thyroid, pituitary, and less commonly, adrenal glands, dilated myocardiopathy, liver fibrosis and cirrhosis. Patients with thalassemia intermedia present later in life with moderate anemia and do not require regular transfusions. Main clinical features in these patients are hypertrophy of erythroid marrow with medullary and extramedullary hematopoiesis and its complications (osteoporosis, masses of erythropoietic tissue that primarily affect the spleen, liver, lymph nodes, chest and spine, and bone deformities and typical facial changes, gallstones, painful leg ulcers and increased predisposition to thrombosis. Thalassemia minor is clinically asymptomatic but some subjects may have moderate anemia. Beta-thalassemias are caused by point mutations or, more rarely

  11. Beta and Gamma Gradients

    DEFF Research Database (Denmark)

    Løvborg, Leif; Gaffney, C. F.; Clark, P. A.

    1985-01-01

    Experimental and/or theoretical estimates are presented concerning, (i) attenuation within the sample of beta and gamma radiation from the soil, (ii) the gamma dose within the sample due to its own radioactivity, and (iii) the soil gamma dose in the proximity of boundaries between regions...... of differing radioactivity. It is confirmed that removal of the outer 2 mm of sample is adequate to remove influence from soil beta dose and estimates are made of the error introduced by non-removal. Other evaluations include variation of the soil gamma dose near the ground surface and it appears...... that the present practice of avoiding samples above a depth of 0.3 m may be over-cautious...

  12. Beta and muon decays

    Energy Technology Data Exchange (ETDEWEB)

    Galindo, A; Pascual, P

    1967-07-01

    These notes represent a series of lectures delivered by the authors in the Junta de Energia Nuclear, during the Spring term of 1965. They were devoted to graduate students interested in the Theory of Elementary Particles. Special emphasis was focussed into the computational problems. Chapter I is a review of basic principles (Dirac equation, transition probabilities, final state interactions.) which will be needed later. In Chapter II the four-fermion punctual Interaction is discussed, Chapter III is devoted to the study of beta-decay; the main emphasis is given to the deduction of the formulae corresponding to electron-antineutrino correlation, electron energy spectrum, lifetimes, asymmetry of electrons emitted from polarized nuclei, electron and neutrino polarization and time reversal invariance in beta decay. In Chapter IV we deal with the decay of polarized muons with radiative corrections. Chapter V is devoted to an introduction to C.V.C. theory. (Author)

  13. Measurement of radionuclides using ion chromatography and flow-cell scintillation counting with pulse shape discrimination

    International Nuclear Information System (INIS)

    DeVol, T.A.; Fjeld, R.A.

    1995-01-01

    A project has been initiated at Clemson Univ. to develop a HPLC/flow- cell system for analysis of non-gamma emitting radionuclides in environmental samples; an important component is development of a low background flow-cell detector that counts alpha and beta particles separately through pulse shape discrimination. Objective of the work presented here is to provide preliminary results of an evaluation of the following scintillators: CaF 2 :Eu, scintillating glass, and BaF 2 . Slightly acidic aqueous solutions of the alpha emitter 233 U and the beta emitter 45 Ca were used. Detection efficiencies and minimum detectable activities were determined

  14. Landscape History of Grosses Moos, NW Swiss Alpine Foreland.

    Science.gov (United States)

    Joanna Heer, Aleksandra; Adamiec, Grzegorz; Veit, Heinz; May, Jan-Hendrik; Novenko, Elena; Hajdas, Irka

    2017-04-01

    The western Swiss Plateau with Lake Neuchâtel is part of the alpine foreland and among the key areas for the reconstruction of environmental changes since the last postglacial. This study was carried out in a landscape located NE of the lake and called Grosses Moos (The Large Fen) - currently designated the Swiss largest, continuous farming area, after the fen was drained in course of landscape engineering projects performed in Switzerland at the end of the 19th century. The study contributes new results from nine excavations of littoral ridges identified in Grosses Moos, and integrates sedimentology, paleo-environmental analysis and three independent chronological methods. Radiocarbon dating, pollen analysis and optically stimulated luminescence (OSL) were applied to the sediments. While pollen and radiocarbon follow the standard procedures, the evaluation of the luminescence age estimates demanded adjustment according to the physical and microdosimetric properties of the alpine quartz, and consideration of the peculiarities of the changing littoral environments of Grosses Moos. The Grosses Moos landscape developed on the temporary surface of the post-Last Glacial sedimentary infill of the over-deepened glacial Aare valley. In this study the landscape history has been fitted into the existing supraregional time scales of NGRIP, the Swiss bio-zones system and the human history based on archaeological and historic records and covers a time span of up to 15'000 yr b2k. The wide-ranging suite of geomorphic features and sedimentary sequences, including littoral lake sediments, beach ridges, dunes, palaeo-channels, peat and colluvial deposits, enable the extensive reconstruction of spatially and temporally variable natural shaping processes. In addition, our results indicate remobilization of soil, colluvium, and sediment due to human settlement activities since the Neolithic - with an important increase in sediment load and spatial variability since the Bronze Age

  15. Regulation of beta cell replication

    DEFF Research Database (Denmark)

    Lee, Ying C; Nielsen, Jens Høiriis

    2008-01-01

    Beta cell mass, at any given time, is governed by cell differentiation, neogenesis, increased or decreased cell size (cell hypertrophy or atrophy), cell death (apoptosis), and beta cell proliferation. Nutrients, hormones and growth factors coupled with their signalling intermediates have been...... suggested to play a role in beta cell mass regulation. In addition, genetic mouse model studies have indicated that cyclins and cyclin-dependent kinases that determine cell cycle progression are involved in beta cell replication, and more recently, menin in association with cyclin-dependent kinase...... inhibitors has been demonstrated to be important in beta cell growth. In this review, we consider and highlight some aspects of cell cycle regulation in relation to beta cell replication. The role of cell cycle regulation in beta cell replication is mostly from studies in rodent models, but whether...

  16. High beta experiments in CHS

    International Nuclear Information System (INIS)

    Okamura, S.; Matsuoka, K.; Nishimura, K.

    1994-09-01

    High beta experiments were performed in the low-aspect-ratio helical device CHS with the volume-averaged equilibrium beta up to 2.1 %. These values (highest for helical systems) are obtained for high density plasmas in low magnetic field heated with two tangential neutral beams. Confinement improvement given by means of turning off gas puffing helped significantly to make high betas. Magnetic fluctuations increased with increasing beta, but finally stopped to increase in the beta range > 1 %. The coherent modes appearing in the magnetic hill region showed strong dependence on the beta values. The dynamic poloidal field control was applied to suppress the outward plasma movement with the plasma pressure. Such an operation gave fixed boundary operations of high beta plasmas in helical systems. (author)

  17. Beta rays and neutrinos

    International Nuclear Information System (INIS)

    Adams, S.F.

    1992-01-01

    It was over 30 years between the first observation of the enigmatic process of beta decay and the first postulation of the neutrino. It took a further 26 years until the first neutrino was detected and yet another 27 until the electroweak theory was confirmed by the discovery of W and Z particles. This article traces some of the puzzles and paradoxes associated with the history of the neutrino. (author)

  18. Coroutine Sequencing in BETA

    DEFF Research Database (Denmark)

    Kristensen, Bent Bruun; Madsen, Ole Lehrmann; Møller-Pedersen, Birger

    In object-oriented programming, a program execution is viewed as a physical model of some real or imaginary part of the world. A language supporting object-oriented programming must therefore contain comprehensive facilities for modeling phenomena and concepts form the application domain. Many...... applications in the real world consist of objects carrying out sequential processes. Coroutines may be used for modeling objects that alternate between a number of sequential processes. The authors describe coroutines in BETA...

  19. COM Support in BETA

    DEFF Research Database (Denmark)

    Madsen, Ole Lehrmann

    1999-01-01

    Component technologies based on binary units of independent production are some of the most important contributions to software architecture and reuse during recent years. Especially the COM technologies and the CORBA standard from the Object Management Group have contributed new and interesting...... principles for software architecture, and proven to be useful in parctice. In this paper ongoing work with component support in the BETA language is described....

  20. LHCb: $2\\beta_s$ measurement at LHCb

    CERN Multimedia

    Conti, G

    2009-01-01

    A measurement of $2\\beta_s$, the phase of the $B_s-\\bar{B_s}$ oscillation amplitude with respect to that of the ${\\rm b} \\rightarrow {\\rm c^{+}}{\\rm W^{-}}$ tree decay amplitude, is one of the key goals of the LHCb experiment with first data. In the Standard Model (SM), $2\\beta_s$ is predicted to be $0.0360^{+0.0020}_{-0.0016} \\rm rad$. The current constraints from the Tevatron are: $2\\beta_{s}\\in[0.32 ; 2.82]$ at 68$\\%$CL from the CDF experiment and $2\\beta_{s}=0.57^{+0.24}_{-0.30}$ from the D$\\oslash$ experiment. Although the statistical uncertainties are large, these results hint at the possible contribution of New Physics in the $B_s-\\bar{B_s}$ box diagram. After one year of data taking at LHCb at an average luminosity of $\\mathcal{L}\\sim2\\cdot10^{32}\\rm cm^{-2} \\rm s^{-1}$ (integrated luminosity $\\mathcal{L}_{\\rm int}\\sim 2 \\rm fb^{-1}$), the expected statistical uncertainty on the measurement is $\\sigma(2\\beta_s)\\simeq 0.03$. This uncertainty is similar to the $2\\beta_s$ value predicted by the SM.

  1. 26 CFR 1.61-14 - Miscellaneous items of gross income.

    Science.gov (United States)

    2010-04-01

    ... as treble damages under the antitrust laws and exemplary damages for fraud are gross income. Another... by law. Illegal gains constitute gross income. Treasure trove, to the extent of its value in United...

  2. Repeatability of differential goat bulk milk culture and associations with somatic cell count, total bacterial count, and standard plate count

    NARCIS (Netherlands)

    Koop, G.; Dik, N.; Nielen, M.; Lipman, L.J.A.

    2010-01-01

    The aims of this study were to assess how different bacterial groups in bulk milk are related to bulk milk somatic cell count (SCC), bulk milk total bacterial count (TBC), and bulk milk standard plate count (SPC) and to measure the repeatability of bulk milk culturing. On 53 Dutch dairy goat farms,

  3. Nearest neighbors by neighborhood counting.

    Science.gov (United States)

    Wang, Hui

    2006-06-01

    Finding nearest neighbors is a general idea that underlies many artificial intelligence tasks, including machine learning, data mining, natural language understanding, and information retrieval. This idea is explicitly used in the k-nearest neighbors algorithm (kNN), a popular classification method. In this paper, this idea is adopted in the development of a general methodology, neighborhood counting, for devising similarity functions. We turn our focus from neighbors to neighborhoods, a region in the data space covering the data point in question. To measure the similarity between two data points, we consider all neighborhoods that cover both data points. We propose to use the number of such neighborhoods as a measure of similarity. Neighborhood can be defined for different types of data in different ways. Here, we consider one definition of neighborhood for multivariate data and derive a formula for such similarity, called neighborhood counting measure or NCM. NCM was tested experimentally in the framework of kNN. Experiments show that NCM is generally comparable to VDM and its variants, the state-of-the-art distance functions for multivariate data, and, at the same time, is consistently better for relatively large k values. Additionally, NCM consistently outperforms HEOM (a mixture of Euclidean and Hamming distances), the "standard" and most widely used distance function for multivariate data. NCM has a computational complexity in the same order as the standard Euclidean distance function and NCM is task independent and works for numerical and categorical data in a conceptually uniform way. The neighborhood counting methodology is proven sound for multivariate data experimentally. We hope it will work for other types of data.

  4. The relationship between gross motor skills and visual perception of preschoolers

    OpenAIRE

    TEPELI, Kezban

    2014-01-01

    Answers were searched for these questions; “Is there a relationship between visual perceptions and gross motor skills of preschool children?”, “Are preschool children's visual perceptions predictors of their gross motor skills?”, “Is there any difference between visual perceptions of the children having low, average and high level of gross motor skills?” within this study where the relationship between preschool children's visual perceptions and their gross motor skills were compara...

  5. Liquid scintillation counting techniques for the determination of some alpha emitting actinides: a review

    International Nuclear Information System (INIS)

    Mirashi, N.N.; Chander, Keshav; Aggarwal, S.K.

    2000-12-01

    The present report is a review of the work on liquid scintillation counting techniques, for the determination of alpha emitting actinides like uranium, plutonium, americium etc; for the last three decades (1970-1999). It covers the progress that has taken place in conventional liquid scintillation counting employing various solvents, scintillators and extractants. There is gradual development in instrumentation from integral counting of alpha emitters to alpha liquid scintillation spectrometry to resolve and identify different alpha emitters. These advancements have led to Pulse Shape Analysis (PSA) and Photon Electron Rejecting Alpha Liquid Scintillation Spectrometry (PERALS) techniques for the determination of the alpha emitters in the presence of beta and gamma activity. These techniques allow the determination of actinides at very low levels which has increased their applications to almost all the fields of chemistry; be it biomedical, environmental, geological or process chemistry of nuclear fuels. The development of biphasic technique using various extractants to separate different elements and counting in presence of one another has been made possible. Inorganic scintillators have been recently developed which have the advantage of eliminating effects of quenching and presence of beta/gamma emitting actinides. This review will serve as a reference to those who want to carry out work in the field of determination of actinides using liquid scintillation counting techniques. (author)

  6. CalCOFI Egg Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish egg counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets], and...

  7. CalCOFI Larvae Counts Positive Tows

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Fish larvae counts and standardized counts for eggs captured in CalCOFI icthyoplankton nets (primarily vertical [Calvet or Pairovet], oblique [bongo or ring nets],...

  8. Alaska Steller Sea Lion Pup Count Database

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This database contains counts of Steller sea lion pups on rookeries in Alaska made between 1961 and 2015. Pup counts are conducted in late June-July. Pups are...

  9. Xe isotope detection and discrimination using beta spectroscopy with coincident gamma spectroscopy

    Science.gov (United States)

    Reeder, P. L.; Bowyer, T. W.

    1998-02-01

    Beta spectroscopic techniques show promise of significant improvements for a beta-gamma coincidence counter that is part of a system for analyzing Xe automatically separated from air. The previously developed counting system for 131mXe, 133mXe, 133gXe, and 135gXe can be enhanced to give additional discrimination between these Xe isotopes by using the plastic scintillation sample cell as a beta spectrometer to resolve the conversion electron peaks. The automated system will be a key factor in monitoring the Comprehensive Test Ban Treaty.

  10. 17-beta-estradiol upregulates the stress response in Candida albicans: implications for microbial virulence.

    OpenAIRE

    O'Connor, C; Essmann, M; Larsen, B

    1998-01-01

    OBJECTIVE: The influence of 17-beta-estradiol on the stress response of Candida albicans was studied. METHODS: The survival of clinical isolates of C. albicans treated with 17-beta-estradiol after heat and oxidative stress was measured by viable plate counts. Cellular proteins were analyzed via SDS-PAGE. RESULTS: The heat stress response induced by 17-beta-estradiol in C. albicans grown at 25 degrees C protected the organisms against the lethal temperature of 48.5 degrees C, as shown by viabl...

  11. Low-dimensional chiral physics. Gross-Neveu universality and magnetic catalysis

    Energy Technology Data Exchange (ETDEWEB)

    Scherer, Daniel David

    2012-09-27

    beyond the determination of critical exponents, we analyze the Gross-Neveu beta functions at finite temperature. The critical temperature for the 2nd order phase transition within the 2d-Ising universality class is determined as a function of the number of fermion species and we try to quantitatively describe the suppression of the so-called Ginzburg region with the number of fermion flavors. Finally we analyze the minimal coupling of the fermionic degrees of freedom to a background magnetic field that leads to the phenomenon of magnetic catalysis. The external magnetic field modifies the mode structure of the free theory to relativistic Landau levels, enhancing the efficiency of quantum fluctuations by dimensional reduction, thus leading to spontaneous symmetry breaking even for subcritical values of the coupling. We identify the corresponding renormalization group mechanism and quantitatively study the magnetic field dependence of the dynamically generated spectral gap.

  12. Low-dimensional chiral physics. Gross-Neveu universality and magnetic catalysis

    International Nuclear Information System (INIS)

    Scherer, Daniel David

    2012-01-01

    of critical exponents, we analyze the Gross-Neveu beta functions at finite temperature. The critical temperature for the 2nd order phase transition within the 2d-Ising universality class is determined as a function of the number of fermion species and we try to quantitatively describe the suppression of the so-called Ginzburg region with the number of fermion flavors. Finally we analyze the minimal coupling of the fermionic degrees of freedom to a background magnetic field that leads to the phenomenon of magnetic catalysis. The external magnetic field modifies the mode structure of the free theory to relativistic Landau levels, enhancing the efficiency of quantum fluctuations by dimensional reduction, thus leading to spontaneous symmetry breaking even for subcritical values of the coupling. We identify the corresponding renormalization group mechanism and quantitatively study the magnetic field dependence of the dynamically generated spectral gap.

  13. SCINFI II A program to calculate the standardization curve in liquid scintillation counting

    Energy Technology Data Exchange (ETDEWEB)

    Grau Carles, A.; Grau Malonda, A.

    1985-07-01

    A code, SCINFI II, written in BASIC, has been developed to compute the efficiency-quench standardization curve for any beta radionuclide. The free parameter method has been applied. The program requires the standardization curve for 3{sup H} and the polynomial or tabulated relating counting efficiency as figure of merit for both 3{sup H} and the problem radionuclide. The program is applied to the computation, of the counting efficiency for different values of quench when the problem is 14{sup C}. The results of four different computation methods are compared. (Author) 17 refs.

  14. SCINFI II A program to calculate the standardization curve in liquid scintillation counting

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    1985-01-01

    A code, SCINFI II, written in BASIC, has been developed to compute the efficiency-quench standardization curve for any beta radionuclide. The free parameter method has been applied. The program requires the standardization curve for 3 H and the polynomial or tabulated relating counting efficiency as figure of merit for both 3 H and the problem radionuclide. The program is applied to the computation, of the counting efficiency for different values of quench when the problem is 14 C . The results of four different computation methods are compared. (Author) 17 refs

  15. Determination of cosmic ray produced radionuclides by means of background radiation counting system, 3

    International Nuclear Information System (INIS)

    1976-01-01

    This is the third report of the progress report series on studies of cosmic ray produced radionuclides by means of low background radiation counting system. In Part I some characteristics of a low beta-gamma coincidence spectrometer are described -- counter system, electronics, background spectra, counting efficiencies -- and studies on radioactive impurities in materials for scientific research are also described. In Part II, suitable solvents for a large scale liquid scintillation counter were examined and best combinations of solvents, solutes and naphthalene are shown. In Part III, miscellaneous topics are reported. (auth.)

  16. 26 CFR 1.924(a)-1T - Temporary regulations; definition of foreign trading gross receipts.

    Science.gov (United States)

    2010-04-01

    ... trading gross receipts. 1.924(a)-1T Section 1.924(a)-1T Internal Revenue INTERNAL REVENUE SERVICE... United States § 1.924(a)-1T Temporary regulations; definition of foreign trading gross receipts. (a) In general. The term “foreign trading gross receipts” means any of the five amounts described in paragraphs...

  17. 26 CFR 1.61-3 - Gross income derived from business.

    Science.gov (United States)

    2010-04-01

    ... Section 1.61-3 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Definition of Gross Income, Adjusted Gross Income, and..., merchandising, or mining business, “gross income” means the total sales, less the cost of goods sold, plus any...

  18. 46 CFR 167.01-8 - Inspection of school ships using gross tonnage criterion.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Inspection of school ships using gross tonnage criterion... SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS General Provisions § 167.01-8 Inspection of school ships using gross... school ships by relative sizes in gross tonnages. When it is determined in accordance with § 70.05-20 of...

  19. The Relationship between Gross Motor Skills and Academic Achievement in Children with Learning Disabilities

    Science.gov (United States)

    Westendorp, Marieke; Hartman, Esther; Houwen, Suzanne; Smith, Joanne; Visscher, Chris

    2011-01-01

    The present study compared the gross motor skills of 7- to 12-year-old children with learning disabilities (n = 104) with those of age-matched typically developing children (n = 104) using the Test of Gross Motor Development-2. Additionally, the specific relationships between subsets of gross motor skills and academic performance in reading,…

  20. 26 CFR 1.872-1 - Gross income of nonresident alien individuals.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 9 2010-04-01 2010-04-01 false Gross income of nonresident alien individuals. 1...) INCOME TAX (CONTINUED) INCOME TAXES Nonresident Aliens and Foreign Corporations § 1.872-1 Gross income of nonresident alien individuals. (a) In general—(1) Inclusions. The gross income of a nonresident alien...

  1. The relationship between gross motor skills and academic achievement in children with learning disabilities

    NARCIS (Netherlands)

    Westendorp, Marieke; Hartman, Esther; Houwen, Suzanne; Smith, Joanne; Visscher, Chris

    2011-01-01

    The present study compared the gross motor skills of 7- to 12-year-old children with learning disabilities (n = 104) with those of age-matched typically developing children (n = 104) using the Test of Gross Motor Development-2. Additionally, the specific relationships between subsets of gross motor

  2. Beta-adrenergic receptors of lymphocytes in children with allergic respiratory diseases

    International Nuclear Information System (INIS)

    Bittera, I.; Gyurkovits, K.; Falkay, G.; Eck, E.; Koltai, M.

    1988-01-01

    The beta-adrenergic receptor binding sites on peripheral lymphocytes in children with bronchial asthma (n = 16) and seasonal allergic rhinitis (n = 8) were examined in comparison with normal controls (n = 18) by means of 124 I-cyanopindolol. The number of beta-adrenergic receptors was significantly lower in the asthmatic group (858 +/- 460/lymphocyte) than in the controls (1564 +/- 983/lymphocyte). The value (1891 +/- 1502/lymphocyte in children with allergic rhinitis was slightly higher than that in healthy controls. Of the 24 patients suffering from allergic diseases of the lower or upper airways, the bronchial histamine provocation test was performed in 21; 16 gave positive results, while 5 were negative. No difference in beta-adrenergic receptor count was found between the histamine-positive and negative patients. Neither was there any correlation between the number of beta-adrenergic receptors and the high (16/24) and low (8/24) serum IgE concentrations found in allergic patients. The significant decrease in beta-adrenergic receptor count in asthmatic children lends support to Szentivanyi's concept. Further qualitative and quantitative analysis of lymphocyte beta-adrenergic receptors may provide an individual approach to the treatment of bronchial asthma with beta-sympathomimetic drugs

  3. SPERM COUNT DISTRIBUTIONS IN FERTILE MEN

    Science.gov (United States)

    Sperm concentration and count are often used as indicators of environmental impacts on male reproductive health. Existing clinical databases may be biased towards subfertile men with low sperm counts and less is known about expected sperm count distributions in cohorts of fertil...

  4. Platelet counting using the Coulter electronic counter.

    Science.gov (United States)

    Eggleton, M J; Sharp, A A

    1963-03-01

    A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.

  5. Count-doubling time safety circuit

    International Nuclear Information System (INIS)

    Keefe, D.J.; McDowell, W.P.; Rusch, G.K.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary

  6. Count-doubling time safety circuit

    Science.gov (United States)

    Rusch, Gordon K.; Keefe, Donald J.; McDowell, William P.

    1981-01-01

    There is provided a nuclear reactor count-factor-increase time monitoring circuit which includes a pulse-type neutron detector, and means for counting the number of detected pulses during specific time periods. Counts are compared and the comparison is utilized to develop a reactor scram signal, if necessary.

  7. DC KIDS COUNT e-Databook Indicators

    Science.gov (United States)

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  8. Enantioselective synthesis of alpha,beta-disubstituted-beta-amino acids.

    Science.gov (United States)

    Sibi, Mukund P; Prabagaran, Narayanasamy; Ghorpade, Sandeep G; Jasperse, Craig P

    2003-10-01

    Highly diastereoselective and enantioselective addition of N-benzylhydroxylamine to imides 17 and 20-30 produces alpha,beta-trans-disubstituted N-benzylisoxazolidinones 19 and 31-41. These reactions proceed in 60-96% ee with 93-99% de's using 5 mol % of Mg(NTf2)2 and ligand 18. The product isoxazolidinones can be hydrogenolyzed directly to provide alpha,beta-disubstituted-beta-amino acids.

  9. How much do women count if they not counted?

    Directory of Open Access Journals (Sweden)

    Federica Taddia

    2006-01-01

    Full Text Available The condition of women throughout the world is marked by countless injustices and violations of the most fundamental rights established by the Universal Declaration of human rights and every culture is potentially prone to commit discrimination against women in various forms. Women are worse fed, more exposed to physical violence, more exposed to diseases and less educated; they have less access to, or are excluded from, vocational training paths; they are the most vulnerable among prisoners of conscience, refugees and immigrants and the least considered within ethnic minorities; from their very childhood, women are humiliated, undernourished, sold, raped and killed; their work is generally less paid compared to men’s work and in some countries they are victims of forced marriages. Such condition is the result of old traditions that implicit gender-differentiated education has long promoted through cultural models based on theories, practices and policies marked by discrimination and structured differentially for men and women. Within these cultural models, the basic educational institutions have played and still play a major role in perpetuating such traditions. Nevertheless, if we want to overcome inequalities and provide women with empowerment, we have to start right from the educational institutions and in particular from school, through the adoption of an intercultural approach to education: an approach based on active pedagogy and on methods of analysis, exchange and enhancement typical of socio-educational animation. The intercultural approach to education is attentive to promote the realisation of each individual and the dignity and right of everyone to express himself/herself in his/her own way. Such an approach will give women the opportunity to become actual agents of collective change and to get the strength and wellbeing necessary to count and be counted as human beings entitled to freedom and equality, and to have access to all

  10. Gross anatomy education for South African undergraduate physiotherapy students.

    Science.gov (United States)

    Shead, Dorothy A; Roos, Ronel; Olivier, Benita; Ihunwo, Amadi O

    2018-01-16

    Eight faculties in South Africa offer undergraduate physiotherapy training with gross anatomy included as a basis for clinical practice. Little information exists about anatomy education for this student body. A 42-question peer-reviewed survey was distributed to physiotherapy gross anatomy course coordinators in all the eight faculties. Seven coordinators from six (75%) of the universities responded. Two respondents' data from the same university were pooled. Collected data show that staff qualifications and experience varied widely and high to average staff to student ratios exist between faculties. Direct anatomy teaching duration was 12.3 (SD ±5.2) weeks per semester. Total number of weeks in courses per faculty was 27.6 (SD ±5.7) varying widely between institutions. Calculable direct contact anatomy hours ranged between 100 and 308 with a mean of 207.6 (SD ±78.1). Direct contact hours in lectures averaged 3.9 (SD ±1.6) per week and the average direct contact hours in practical sessions were 3.5 (SD ±1.8) per week. Dissection, prosection, plastinated models, surface anatomy, and e-learning were available across faculties. Ancillary modalities such as vertical integration and inter-professional learning were in use. All faculties had multiple-choice questions, spot tests, and short examination questions. Half had viva-voce examinations and one had additional long questions assessment. Students evaluated teaching performance in five faculties. Four faculties were reviewing anatomy programs to consider implementing changes to anatomy curriculum or pedagogy. The findings highlighted disparity between programs and also identified the need for specific guidelines to develop a unified South African gross anatomy course for physiotherapy students. Anat Sci Educ. © 2018 American Association of Anatomists. © 2018 American Association of Anatomists.

  11. Verbal priming and taste sensitivity make moral transgressions gross.

    Science.gov (United States)

    Herz, Rachel S

    2014-02-01

    The aims of the present study were to assess whether: (a) visceral and moral disgust share a common oral origin (taste); (b) moral transgressions that are also viscerally involving are evaluated accordingly as a function of individual differences in taste sensitivity; (c) verbal priming interacts with taste sensitivity to alter how disgust is experienced in moral transgressions; and (d) whether gender moderates these effects. Standard tests of disgust sensitivity, a questionnaire developed for this research assessing different types of moral transgressions (nonvisceral, implied-visceral, visceral) with the terms "angry" and "grossed-out," and a taste sensitivity test of 6-n-propylthiouracil (PROP) were administered to 102 participants. Results confirmed past findings that the more sensitive to PROP a participant was the more disgusted they were by visceral, but not moral, disgust elicitors. Importantly, the findings newly revealed that taste sensitivity had no bearing on evaluations of moral transgressions, regardless of their visceral nature, when "angry" was the emotion primed. However, when "grossed-out" was primed for evaluating moral violations, the more intense PROP tasted to a participant the more "grossed-out" they were by all transgressions. Women were generally more disgust sensitive and morally condemning than men, but disgust test, transgression type, and priming scale modulated these effects. The present findings support the proposition that moral and visceral disgust do not share a common oral origin, but show that linguistic priming can transform a moral transgression into a viscerally repulsive event and that susceptibility to this priming varies as a function of an individual's sensitivity to the origins of visceral disgust-bitter taste.

  12. Peak-counts blood flow model-errors and limitations

    International Nuclear Information System (INIS)

    Mullani, N.A.; Marani, S.K.; Ekas, R.D.; Gould, K.L.

    1984-01-01

    The peak-counts model has several advantages, but its use may be limited due to the condition that the venous egress may not be negligible at the time of peak-counts. Consequently, blood flow measurements by the peak-counts model will depend on the bolus size, bolus duration, and the minimum transit time of the bolus through the region of interest. The effect of bolus size on the measurement of extraction fraction and blood flow was evaluated by injecting 1 to 30ml of rubidium chloride in the femoral vein of a dog and measuring the myocardial activity with a beta probe over the heart. Regional blood flow measurements were not found to vary with bolus sizes up to 30ml. The effect of bolus duration was studied by injecting a 10cc bolus of tracer at different speeds in the femoral vein of a dog. All intravenous injections undergo a broadening of the bolus duration due to the transit time of the tracer through the lungs and the heart. This transit time was found to range from 4-6 second FWHM and dominates the duration of the bolus to the myocardium for up to 3 second injections. A computer simulation has been carried out in which the different parameters of delay time, extraction fraction, and bolus duration can be changed to assess the errors in the peak-counts model. The results of the simulations show that the error will be greatest for short transit time delays and for low extraction fractions

  13. Gross shell structure at high spin in heavy nuclei

    International Nuclear Information System (INIS)

    Deleplanque, Marie-Agnes; Frauendorf, Stefan; Pashkevich, Vitaly V.; Chu, S.Y.; Unzhakova, Anja

    2003-01-01

    Experimental nuclear moments of inertia at high spins along the yrast line have been determined systematically and found to differ from the rigid-body values. The difference is attributed to shell effect and these have been calculated microscopically. The data and quantal calculations are interpreted by means of the semiclassical Periodic Orbit Theory. From this new perspective, features in the moments of inertia as a function of neutron number and spin, as well as their relation to the shell energies can be understood. Gross shell effects persist up to the highest angular momenta observed

  14. Characterizing the development of sectoral gross domestic product composition

    Science.gov (United States)

    Lutz, Raphael; Spies, Michael; Reusser, Dominik E.; Kropp, Jürgen P.; Rybski, Diego

    2013-07-01

    We consider the sectoral composition of a country's gross domestic product (GDP), i.e., the partitioning into agrarian, industrial, and service sectors. Exploring a simple system of differential equations, we characterize the transfer of GDP shares between the sectors in the course of economic development. The model fits for the majority of countries providing four country-specific parameters. Relating the agrarian with the industrial sector, a data collapse over all countries and all years supports the applicability of our approach. Depending on the parameter ranges, country development exhibits different transfer properties. Most countries follow three of eight characteristic paths. The types are not random but show distinct geographic and development patterns.

  15. A Langevin simulation of the Gross-Neveu spectrum

    International Nuclear Information System (INIS)

    Lacaze, R.; Morel, A.; Petersson, B.

    1989-01-01

    We study the order parameter of Chiral symmetry, and fermion and boson masses in the Gross-Neveu model as a function of the flavour number N and of the Langevin time step ε in the scaling region. The 1/N dependence of the ε=0 value of the order parameter is in excellent agreement with an analytical calculation up to second order. Care is taken of the important two fermion contribution in the bosonic correlation functions. Mass ratios are found to be ε dependent, but their ε=0 extrapolation is compatible with the analytic expectation

  16. Electron scattering from the deuteron using the Gross equation

    Energy Technology Data Exchange (ETDEWEB)

    J.W. Van Orden; N. Devine; F. Gross

    1996-01-01

    The elastic electromagnetic form factors for the deuteron are calculated in the context of a one-boson-exchange model using the Gross or Spectator equation [1]. The formalism is manifestly covariant and gauge invariant. Results are shown for the impulse approximation and for pxy exchange currents. The impulse approximation results are quite close to the available data which suggests that only a relatively small exchange current contribution is required. It is shown that by using a soft form factor for the exchange current, the model provides a very good representation of the data.

  17. Pathology Gross Photography: The Beginning of Digital Pathology.

    Science.gov (United States)

    Rampy, B Alan; Glassy, Eric F

    2015-06-01

    The underutilized practice of photographing anatomic pathology specimens from surgical pathology and autopsies is an invaluable benefit to patients, clinicians, pathologists, and students. Photographic documentation of clinical specimens is essential for the effective practice of pathology. When considering what specimens to photograph, all grossly evident pathology, absent yet expected pathologic features, and gross-only specimens should be thoroughly documented. Specimen preparation prior to photography includes proper lighting and background, wiping surfaces of blood, removing material such as tubes or bandages, orienting the specimen in a logical fashion, framing the specimen to fill the screen, positioning of probes, and using the right-sized scale. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Weak turbulence theory for the Gross-Pitaevskii equation

    International Nuclear Information System (INIS)

    Nazarenko, S.; West, R.; Lvov, Y.

    2001-01-01

    The goal of this paper is to use the ideas developed for the NLSE to derive a weak turbulence theory for a large set of random waves described by the Gross-Pitaevskii equation. An interesting picture emerges even from a naive application of the results already obtained for the NLSE case. Imagine an arbitrary initial excitation; a superposition of modes with energies somewhere in the middle of the potential well. Because of the nonlinear interaction (''collisions'') there is a redistribution of energy E and particles N among the modes. (orig.)

  19. Beta measurement evaluation and upgrade

    International Nuclear Information System (INIS)

    Swinth, K.L.; Rathbun, L.A.; Roberson, P.L.; Endres, G.W.R.

    1986-01-01

    This program focuses on the resolution of problems associated with the field measurement of the beta dose component at Department of Energy (DOE) facilities. The change in DOE programs, including increased efforts in improved waste management and decontamination and decommissioning (D and D) of facilities, coupled with beta measurement problems identified at Three Mile Island has increased the need to improve beta measurements. In FY 1982, work was initiated to provide a continuing effort to identify problems associated with beta dose assessment at DOE facilities. The problems identified resulted in the development of this program. The investigation includes (1) an assessment of measurement systems now in use, (2) development of improved calibration systems and procedures, (3) application of innovative beta dosimetry concepts, (4) investigation of new instruments or concepts for monitoring and spectroscopy, and (5) development of recommendations to assure an adequate beta measurement program within DOE facilities

  20. Beta-thalassaemia trait: haematological parameters

    International Nuclear Information System (INIS)

    Yousafzai, Y.M.; Khan, S.; Raziq, F.

    2010-01-01

    Thalassaemia syndromes are a group of hereditary disorders characterised by a genetic deficiency in the synthesis of --globin genes. The objective of this study was to determine the haematological features -thalassaemia trait (BTT), and to determine the sensitivity of Mean Corpuscular Volume (MCV), Mean Corpuscular Haemoglobin (MCH) and -thalassaemia trait. Methods: A descriptive study was conducted in Hayatabad Medical Complex, Peshawar from May 2009 to May 2010 with 203 subjects having BTT. Blood samples were collected in EDTA anti-coagulated tubes. RBC indices were taken as part of complete blood count (CBC) by haematology analyser, and Haemoglobin (Hb) electrophoresis was done to determine the HbA2 percentage. The data was collected and analyzed on statistical software for demographic details, RBC indices and HBA2 levels. Results: Out of 203 patients, 92 (45%) were males and 111 (55%) were females. Most patients tested were in the 15-45 year age group. One-hundred-sixty (79%) patients had anaemia. MCV was lower than 76 fl in all the cases. Mean MCV was 59.1 fl. MCH was low, the mean MCH being 19.3 g/dl. MCH <26 gave sensitivity of 99% in detecting BTT. We calculated MI for these cases and found out that it was <12 in 75% of cases and <15 in 197 (97%). Conclusion: Beta-thalassaemia traits present with a microcytic hypochromic blood picture, detected on simple haematology analysers as low MCV and MCH and MI which provide a beta- thalassaemia trait. (author)

  1. [Prevalence survey and molecular characterization of alpha and beta thalassemia in Liuzhou city of Guangxi].

    Science.gov (United States)

    Cai, Ren; Li, Liyan; Liang, Xin; Liu, Zhongying; Su, Liu; Li, Wenjun; Zhu, Qiangui; Mo, Qiuhua; Pan, Lizhen; Ouyang, Hong; Huang, Lihua; Xu, Xiangmin

    2002-08-01

    To investigate the gene frequencies and mutation patterns of alpha thalassemia (alpha-thal) and beta thalassemia (beta-thal) in Liuzhou city of Guangxi Zhuang Autonomous Region. Cluster sampling was used. A total of 1 028 of umbilical blood samples were collected for a prevalence study of alpha-thal and a total of 1 312 healthy young people when receiving pre-marriage consultation were recruited for a beta-thal prevalence survey. Individuals live in city or town area of Liuzhou. A complete blood count as well as hemoglobin electrophoresis analysis were done in all of samples for phenotyping of alpha and beta-thals. Those with Hb Bart's for alpha-thal indicator and those with both microcytosis (MCV /=4.0%) for beta-thal were further studied by DNA analysis. PCR-based methodologies were used to characterize the mutation contributions of alpha and beta-thals. All the subjects were tested for the state of carrying beta-thala alleles for evaluating the situation of the compound heterozygotes of alpha-thal with beta-thal. Of 1 028 random samples of umbilical blood screened, 112 of subjects were defined to be the gene carriers of alpha-thal. The alpha-thal carrier rate was as high as 11.19% including 3 compound heterozygotes. Five well-known types of alpha-thal alleles were detected with gene contributions of 37.4% (--(SEA) deletion), 31.3% (-alpha(3.7) deletion), 17.4% (-alpha(4.2) deletion), 12.1% (alpha(CS)alpha mutation), and 0.9% (alpha(QS)alpha mutation), successively. Of the 1 312 adult specimens studied, 89 with beta-thal including 14 of the compound higher Hb F subjects were detected. All of the 89 phenotypic beta-thal carriers had the mutations in the beta-globin gene, making the overall prevalence 6.78%. The commonly seen three mutations, beta CD41 - 42 (-CTTT) frameshift, beta CD17 (T-A) nonsense mutation and beta-28 (A-G) promoter variation were accounted for 90% of the beta-thal alleles in Liuzhou. Of these beta-thal subjects, 16 (accounting for 18%) were

  2. Conditional Betas and Investor Uncertainty

    OpenAIRE

    Fernando D. Chague

    2013-01-01

    We derive theoretical expressions for market betas from a rational expectation equilibrium model where the representative investor does not observe if the economy is in a recession or an expansion. Market betas in this economy are time-varying and related to investor uncertainty about the state of the economy. The dynamics of betas will also vary across assets according to the assets' cash-flow structure. In a calibration exercise, we show that value and growth firms have cash-flow structures...

  3. On-line plutonium measurement by alpha counting using a silica glass sensor

    International Nuclear Information System (INIS)

    Edeline, J.C.; Furgolle, B.

    1980-01-01

    Some cerium activated high purity silica glasses are good sensors for ionising particles counting. These sensors may be used for measuring plutonium concentrations in corrosive solutions which are typical in reprocessing operations. The thickness of the sensor has been reduced to minimize beta sensitivity. The thin sensor is hold by molecular adhesion to a thick glass mount which is soldered to the stainless steel sample cell [fr

  4. Radon counting statistics - a Monte Carlo investigation

    International Nuclear Information System (INIS)

    Scott, A.G.

    1996-01-01

    Radioactive decay is a Poisson process, and so the Coefficient of Variation (COV) of open-quotes nclose quotes counts of a single nuclide is usually estimated as 1/√n. This is only true if the count duration is much shorter than the half-life of the nuclide. At longer count durations, the COV is smaller than the Poisson estimate. Most radon measurement methods count the alpha decays of 222 Rn, plus the progeny 218 Po and 214 Po, and estimate the 222 Rn activity from the sum of the counts. At long count durations, the chain decay of these nuclides means that every 222 Rn decay must be followed by two other alpha decays. The total number of decays is open-quotes 3Nclose quotes, where N is the number of radon decays, and the true COV of the radon concentration estimate is 1/√(N), √3 larger than the Poisson total count estimate of 1/√3N. Most count periods are comparable to the half lives of the progeny, so the relationship between COV and count time is complex. A Monte-Carlo estimate of the ratio of true COV to Poisson estimate was carried out for a range of count periods from 1 min to 16 h and three common radon measurement methods: liquid scintillation, scintillation cell, and electrostatic precipitation of progeny. The Poisson approximation underestimates COV by less than 20% for count durations of less than 60 min

  5. Dynamic returns of beta arbitrage

    OpenAIRE

    Nascimento, Mafalda

    2017-01-01

    This thesis studies the patterns of the abnormal returns of the beta strategy. The topic can be helpful for professional investors, who intend to achieve a better performance in their portfolios. Following the methodology of Lou, Polk, & Huang (2016), the COBAR measure is computed in order to determine the levels of beta arbitrage in the market in each point in time. It is argued that beta arbitrage activity can have impact on the returns of the beta strategy. In fact, it is demonstrated that...

  6. Integration of BETA with Eclipse

    DEFF Research Database (Denmark)

    Andersen, Peter; Madsen, Ole Lehrmann; Enevoldsen, Mads Brøgger

    2004-01-01

    This paper presents language interoperability issues appearing in order to implement support for the BETA language in the Java-based Eclipse integrated development environment. One of the challenges is to implement plug-ins in BETA and be able to load them in Eclipse. In order to do this, some fo...... it is possible to implement plug-ins in BETA and even inherit from Java classes. In the paper the two approaches are described together with part of the mapping from BETA to Java class files. http://www.sciencedirect.com/science/journal/15710661...

  7. Simultaneous beta and gamma spectroscopy

    Science.gov (United States)

    Farsoni, Abdollah T.; Hamby, David M.

    2010-03-23

    A phoswich radiation detector for simultaneous spectroscopy of beta rays and gamma rays includes three scintillators with different decay time characteristics. Two of the three scintillators are used for beta detection and the third scintillator is used for gamma detection. A pulse induced by an interaction of radiation with the detector is digitally analyzed to classify the type of event as beta, gamma, or unknown. A pulse is classified as a beta event if the pulse originated from just the first scintillator alone or from just the first and the second scintillator. A pulse from just the third scintillator is recorded as gamma event. Other pulses are rejected as unknown events.

  8. Discrete calculus methods for counting

    CERN Document Server

    Mariconda, Carlo

    2016-01-01

    This book provides an introduction to combinatorics, finite calculus, formal series, recurrences, and approximations of sums. Readers will find not only coverage of the basic elements of the subjects but also deep insights into a range of less common topics rarely considered within a single book, such as counting with occupancy constraints, a clear distinction between algebraic and analytical properties of formal power series, an introduction to discrete dynamical systems with a thorough description of Sarkovskii’s theorem, symbolic calculus, and a complete description of the Euler-Maclaurin formulas and their applications. Although several books touch on one or more of these aspects, precious few cover all of them. The authors, both pure mathematicians, have attempted to develop methods that will allow the student to formulate a given problem in a precise mathematical framework. The aim is to equip readers with a sound strategy for classifying and solving problems by pursuing a mathematically rigorous yet ...

  9. Counting paths with Schur transitions

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Pablo [Department of Physics and Astronomy, University of Lethbridge, Lethbridge, Alberta, T1K 3M4 (Canada); Kemp, Garreth [Department of Physics, University of Johannesburg, P.O. Box 524, Auckland Park 2006 (South Africa); Véliz-Osorio, Alvaro, E-mail: aveliz@gmail.com [Mandelstam Institute for Theoretical Physics, University of the Witwatersrand, WITS 2050, Johannesburg (South Africa); School of Physics and Astronomy, Queen Mary, University of London, Mile End Road, London E1 4NS (United Kingdom)

    2016-10-15

    In this work we explore the structure of the branching graph of the unitary group using Schur transitions. We find that these transitions suggest a new combinatorial expression for counting paths in the branching graph. This formula, which is valid for any rank of the unitary group, reproduces known asymptotic results. We proceed to establish the general validity of this expression by a formal proof. The form of this equation strongly hints towards a quantum generalization. Thus, we introduce a notion of quantum relative dimension and subject it to the appropriate consistency tests. This new quantity finds its natural environment in the context of RCFTs and fractional statistics; where the already established notion of quantum dimension has proven to be of great physical importance.

  10. Mass counting of radioactivity samples

    International Nuclear Information System (INIS)

    Oesterlin, D.L.; Obrycki, R.F.

    1977-01-01

    A method and apparatus for concurrently counting a plurality of radioactive samples is claimed. The position sensitive circuitry of a scintillation camera is employed to sort electrical pulses resulting from scintillations according to the geometrical locations of scintillations causing those pulses. A scintillation means, in the form of a scintillating crystal material or a liquid scintillator, is positioned proximate to an array of radioactive samples. Improvement in the accuracy of pulse classification may be obtained by employing collimating means. If a plurality of scintillation crystals are employed to measure the iodine-125 content of samples, a method and means are provided for correcting for variations in crystal light transmission properties, sample volume, and sample container radiation absorption. 2 claims, 7 drawing figures

  11. Gross morphological changes in premature and post mature human plancentae

    International Nuclear Information System (INIS)

    Sherin, F.; Afzal, E.; Seema, N.

    2015-01-01

    Placenta is a valuable tool for maternal and foetal diseases. Gross pathological changes are seen in the placenta of many disorders of pregnancy, which are associated with high perinatal morbidity and mortality. This study was conducted with the aim to compare the morphological features of preterm, term and post term placentae in our setup. Methods: This cross sectional study was conducted on 150 placentae: 50 were from normal (term) pregnancies considered as control (delivered between 37 to 42 weeks of gestation.), 50 from premature pregnancies (gestational age between 35-37 weeks) from mothers having hypertensive disorders of pregnancy, and 50 from post mature pregnancies (gestational age more than 42 weeks). The placentae were collected from Department of Obstetrics and Gynaecology, Khyber Teaching Hospital, Peshawar, through purposive sampling. Placentae were examined in the department of Anatomy, Khyber Medical College Peshawar. Results: In gross morphological features of placentae (weight and diameter) showed significant (p<0.001) among the groups Conclusion: In was concluded that the hypertensive disorders of the pregnancy adversely influence the morphology of placenta, which leads to the premature delivery. (author)

  12. Exploring the changing learning environment of the gross anatomy lab.

    Science.gov (United States)

    Hopkins, Robin; Regehr, Glenn; Wilson, Timothy D

    2011-07-01

    The objective of this study was to assess the impact of virtual models and prosected specimens in the context of the gross anatomy lab. In 2009, student volunteers from an undergraduate anatomy class were randomly assigned to study groups in one of three learning conditions. All groups studied the muscles of mastication and completed identical learning objectives during a 45-minute lab. All groups were provided with two reference atlases. Groups were distinguished by the type of primary tools they were provided: gross prosections, three-dimensional stereoscopic computer model, or both resources. The facilitator kept observational field notes. A prepost multiple-choice knowledge test was administered to evaluate students' learning. No significant effect of the laboratory models was demonstrated between groups on the prepost assessment of knowledge. Recurring observations included students' tendency to revert to individual memorization prior to the posttest, rotation of models to match views in the provided atlas, and dissemination of groups into smaller working units. The use of virtual lab resources seemed to influence the social context and learning environment of the anatomy lab. As computer-based learning methods are implemented and studied, they must be evaluated beyond their impact on knowledge gain to consider the effect technology has on students' social development.

  13. Leadership and professionalism curriculum in the Gross Anatomy course.

    Science.gov (United States)

    Pawlina, Wojciech; Hromanik, Michael J; Milanese, Tia R; Dierkhising, Ross; Viggiano, Thomas R; Carmichael, Stephen W

    2006-09-01

    Today's physicians must demonstrate both professionalism and leadership skills in order to succeed in largely team-based healthcare environments. The purpose of this study was to determine if professionalism attributes, leadership style, and leadership style adaptability are associated with academic performance among first-year students early in their medical curriculum. Students were divided into 4-member dissection groups for the duration of the Gross and Developmental Anatomy course. Leadership responsibility was randomly assigned to a team member on a rotating basis every 5 weeks. After each 5-week block, student performance was measured by written and practical examinations, and each student assessed their leader's or their own professionalism attributes and leadership style using validated survey instruments. Most students demonstrated either a "selling" only (57%) or "participating" only (30%) leadership style with low to moderate leadership adaptability. "Participating" and "delegating" leadership styles have the highest average group written exam scores (89.4%, P leadership styles and aspects of professionalism are associated with written and practical examination scores in the Gross and Developmental Anatomy course. Furthermore, it demonstrates that first-year medical students are in need of leadership skill development.

  14. Electricity prices and generator behaviour in gross pool electricity markets

    International Nuclear Information System (INIS)

    O'Mahoney, Amy; Denny, Eleanor

    2013-01-01

    Electricity market liberalisation has become common practice internationally. The justification for this process has been to enhance competition in a market traditionally characterised by statutory monopolies in an attempt to reduce costs to end-users. This paper endeavours to see whether a pool market achieves this goal of increasing competition and reducing electricity prices. Here the electricity market is set up as a sealed bid second price auction. Theory predicts that such markets should result with firms bidding their marginal cost, thereby resulting in an efficient outcome and lower costs to consumers. The Irish electricity system with a gross pool market experiences among the highest electricity prices in Europe. Thus, we analyse the Irish pool system econometrically in order to test if the high electricity prices seen there are due to participants bidding outside of market rules or out of line with theory. Overall we do not find any evidence that the interaction between generator and the pool in the Irish electricity market is not efficient. Thus, the pool element of the market structure does not explain the high electricity prices experienced in Ireland. - Highlights: • We consider whether a gross pool achieves competitive behaviour. • We analyse the Irish pool system econometrically. • Results indicate the Irish pool system appears to work efficiently. • Generators appear to be bidding appropriately

  15. Standardisation of 64Cu using a software coincidence counting system

    International Nuclear Information System (INIS)

    Havelka, Miroslav; Sochorová, Jana

    2014-01-01

    The activity of the radionuclide 64 Cu was determined by the efficiency extrapolation method applied to 4π(PC)−γ coincidence counting. The standardisation was performed by software coincidence counting—a digital method for primary activity measurement that simplifies the setting of optimal coincidence parameters. The γ-ray-energy window, characterised by identical gamma detection efficiency related to the sum of EC and to the sum of beta decay branches, was found. This setting ensured a linear and zero slope extrapolation curve. - Highlights: • Standardisation realised by extrapolation method applied to 4π(PC)−γ coincidence. • Digital method for optimal setting of coincidence parameters was used. • Result with total standard uncertainty of 0.74% was obtained

  16. Determination of plutonium-241 by liquid scintillation counting method and its application to environmental samples

    International Nuclear Information System (INIS)

    Watanabe, Miki; Amano, Hikaru

    1997-03-01

    Radionuclides are usually measured by gross counting mode in liquid scintillator counting (LSC) which measures both α and β pulses. This method can easily measure radioactivities, but its background counting is high. Recently reported α-β pulse shape discrimination method (α-β PSD method) in LSC which distinguishes α pulses from β pulses, shows low background counting, so it makes the detection limit lower. The aim of this research is to develop the best method for the determination of 241 Pu which is β-emitter, and Pu isotopes of α-emitters which have long half-lives and stay long in animal body. In this research, two LSC machines was carried out in different scintillators, vial volumes, measurement modes and so on. The following things were found. 1. The liquid scintillator based on naphthalene is proved to be the best separator of α-ray from β-ray, because it acts quickly in energy translation procedure between solvent and aromatic compounds. 2. α-β PSD method makes the background counting rate ten times lower than usual method. It makes the measurement performance better. 3. It is possible to determine 241 Pu in environmental samples around Chernobyl by the combination of LSC and radiochemical separation methods. (author)

  17. Identification of active anti-inflammatory principles of beta- beta ...

    African Journals Online (AJOL)

    chromatography. Components of the extracts were identified by thin layer chromatography (TLC) scanner and UV-visible spectroscopy, using scopoletin as standard. Results: ... basic coumarin skeleton ring structure reduce ... Figure 2: Thin-layer chromatogram: (1) Ethanol extract; (2) Dichloromethane fraction; (3) Beta-beta.

  18. Improved limits on beta(-) and beta(-) decays of Ca-48

    Czech Academy of Sciences Publication Activity Database

    Bakalyarov, A.; Balysh, A.; Barabash, AS.; Beneš, P.; Briancon, C.; Brudanin, V. B.; Čermák, P.; Egorov, V.; Hubert, F.; Hubert, P.; Korolev, NA.; Kosjakov, VN.; Kovalík, Alojz; Lebedev, NA.; Novgorodov, A. F.; Rukhadze, NI.; Štekl, NI.; Timkin, VV.; Veleshko, IE.; Vylov, T.; Umatov, VI.

    2002-01-01

    Roč. 76, č. 9 (2002), s. 545-547 ISSN 0021-3640 Institutional research plan: CEZ:AV0Z1048901 Keywords : beta decay * double beta decay * Ca-48 Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.483, year: 2002

  19. Conversion of beta-methylbutyric acid to beta-hydroxy-beta-methylbutyric acid by Galactomyces reessii.

    OpenAIRE

    Lee, I Y; Nissen, S L; Rosazza, J P

    1997-01-01

    beta-Hydroxy-beta-methylbutyric acid (HMB) has been shown to increase strength and lean mass gains in humans undergoing resistance-exercise training. HMB is currently marketed as a calcium salt of HMB, and thus, environmentally sound and inexpensive methods of manufacture are being sought. This study investigates the microbial conversion of beta-methylbutyric acid (MBA) to HMB by cultures of Galactomyces reessii. Optimal concentrations of MBA were in the range of 5 to 20 g/liter for HMB produ...

  20. Criteria for requesting specific radionuclide analysis through gross α and gross β concentration measurements in environmental samples

    International Nuclear Information System (INIS)

    Ferreira, E.G.

    1988-01-01

    This paper suggests some criteria for the decision to proceed with the analysis of specific radionuclides based on results of the determination of gross α and β concentrations in environmental samples of aerosols, water, dairy and agricultural products, soil and sediments. The samples considered are provenient from the environmental surveillance of uranium mining and milling facilities as well as the mining and processing plants of monazite sands. The radionuclides to be analysed are those considered to be the most critical to human health, that is: U-nat; Th-nat; Th-230; Ra-228; Ra-226; Po-210; Pb-210. The measured gross α and β concentrations will be compared with the Maximum Allowable Concentrations for some defined radionuclides. Radiochemical analysis of specific radionuclides may then become necessary, depending upon the results of this comparison. The main goal of the proposed guide is to simplify and to discipline the execution of environmental surveillance programs in a safe and economical way, avoiding unnecessary analysis. (author) [pt

  1. The best-beta CAPM

    NARCIS (Netherlands)

    Zou, L.

    2006-01-01

    The issue of 'best-beta' arises as soon as potential errors in the Sharpe-Lintner-Black capital asset pricing model (CAPM) are acknowledged. By incorporating a target variable into the investor preferences, this study derives a best-beta CAPM (BCAPM) that maintains the CAPM's theoretical appeal and

  2. Beta decay of Cu-56

    NARCIS (Netherlands)

    Borcea, R; Aysto, J; Caurier, E; Dendooven, P; Doring, J; Gierlik, M; Gorska, M; Grawe, H; Hellstrom, M; Janas, Z; Jokinen, A; Karny, M; Kirchner, R; La Commara, M; Langanke, K; Martinez-Pinedo, G; Mayet, P; Nieminen, A; Nowacki, F; Penttila, H; Plochocki, A; Rejmund, M; Roeckl, E; Schlegel, C; Schmidt, K; Schwengner, R; Sawicka, M

    2001-01-01

    The proton-rich isotope Cu-56 was produced at the GSI On-Line Mass Separator by means of the Si-28(S-32, p3n) fusion-evaporation reaction. Its beta -decay properties were studied by detecting beta -delayed gamma rays and protons. A half-Life of 93 +/- 3 ms was determined for Cu-56. Compared to the

  3. BETA SPECTRA. I. Negatrons spectra

    International Nuclear Information System (INIS)

    Grau Malonda, A.; Garcia-Torano, E.

    1978-01-01

    Using the Fermi theory of beta decay, the beta spectra for 62 negatrons emitters have been computed introducing a correction factor for unique forbidden transitions. These spectra are plotted vs. energy, once normal i sed, and tabulated with the related Fermi functions. The average and median energies are calculated. (Author)

  4. Review of the beta situation

    International Nuclear Information System (INIS)

    Sheffield, J.

    1982-01-01

    This note lists some of the possible causes of beta limitation in tokamak and discusses what is known and what is involved in investigating them. The motivation for preparing this note is the observed degradation of confinement with increasing beta poloidal β/sub p/ and beam power P/sub b/ in ISX-B

  5. RAVEN Beta Release

    International Nuclear Information System (INIS)

    Rabiti, Cristian; Alfonsi, Andrea; Cogliati, Joshua Joseph; Mandelli, Diego; Kinoshita, Robert Arthur; Wang, Congjian; Maljovec, Daniel Patrick; Talbot, Paul William

    2016-01-01

    This documents the release of the Risk Analysis Virtual Environment (RAVEN) code. A description of the RAVEN code is provided, and discussion of the release process for the M2LW-16IN0704045 milestone. The RAVEN code is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is capable of investigating the system response as well as the input space using Monte Carlo, Grid, or Latin Hyper Cube sampling schemes, but its strength is focused toward system feature discovery, such as limit surfaces, separating regions of the input space leading to system failure, using dynamic supervised learning techniques. RAVEN has now increased in maturity enough for the Beta 1.0 release.

  6. RAVEN Beta Release

    Energy Technology Data Exchange (ETDEWEB)

    Rabiti, Cristian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Alfonsi, Andrea [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cogliati, Joshua Joseph [Idaho National Lab. (INL), Idaho Falls, ID (United States); Mandelli, Diego [Idaho National Lab. (INL), Idaho Falls, ID (United States); Kinoshita, Robert Arthur [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wang, Congjian [Idaho National Lab. (INL), Idaho Falls, ID (United States); Maljovec, Daniel Patrick [Idaho National Lab. (INL), Idaho Falls, ID (United States); Talbot, Paul William [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-02-01

    This documents the release of the Risk Analysis Virtual Environment (RAVEN) code. A description of the RAVEN code is provided, and discussion of the release process for the M2LW-16IN0704045 milestone. The RAVEN code is a generic software framework to perform parametric and probabilistic analysis based on the response of complex system codes. RAVEN is capable of investigating the system response as well as the input space using Monte Carlo, Grid, or Latin Hyper Cube sampling schemes, but its strength is focused toward system feature discovery, such as limit surfaces, separating regions of the input space leading to system failure, using dynamic supervised learning techniques. RAVEN has now increased in maturity enough for the Beta 1.0 release.

  7. Gross and fine motor function in fibromyalgia and chronic fatigue syndrome

    Directory of Open Access Journals (Sweden)

    Rasouli O

    2017-02-01

    Full Text Available Omid Rasouli,1,2 Egil A Fors,3 Petter Chr Borchgrevink,4,5 Fredrik Öhberg,6 Ann-Katrin Stensdotter1 1Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway; 2Department of Public Health and Nursing, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway; 3Department of Public Health and Nursing, General Practice Research Unit, Norwegian University of Science and Technology, Trondheim, Norway; 4Department of Circulation and Medical Imaging, Pain and Palliation Research Group, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, Trondheim, Norway; 5National Competence Centre for Complex Symptom Disorders, St. Olav’s University Hospital, Trondheim, Norway; 6Department of Radiation Sciences, Biomedical Engineering, Umeå University, Umeå, Sweden Purpose: This paper aimed to investigate motor proficiency in fine and gross motor function, with a focus on reaction time (RT and movement skill, in patients with fibromyalgia (FM and chronic fatigue syndrome (CFS compared to healthy controls (HC.Methods: A total of 60 individuals (20 CFS, 20 FM, and 20 HC, age 19–49 years, participated in this study. Gross motor function in the lower extremity was assessed using a RT task during gait initiation in response to an auditory trigger. Fine motor function in the upper extremity was measured during a precision task (the Purdue Pegboard test where the number of pins inserted within 30 s was counted.Results: No significant differences were found between FM and CFS in any parameters. FM and CFS groups had significantly longer RT than HC in the gait initiation (p=0.001, and p=0.004 respectively. In the Purdue Pegboard test, 20% in the FM group, 15% in the CFS groups, and 0% of HC group, scored below the threshold of the accepted performance. However, there were no

  8. Interactions between two beta-sheets. Energetics of beta/beta packing in proteins.

    Science.gov (United States)

    Chou, K C; Némethy, G; Rumsey, S; Tuttle, R W; Scheraga, H A

    1986-04-20

    The analysis of the interactions between regularly folded segments of the polypeptide chain contributes to an understanding of the energetics of protein folding. Conformational energy-minimization calculations have been carried out to determine the favorable ways of packing two right-twisted beta-sheets. The packing of two five-stranded beta-sheets was investigated, with the strands having the composition CH3CO-(L-Ile)6-NHCH3 in one beta-sheet and CH3CO-(L-Val)6-NHCH3 in the other. Two distinct classes of low-energy packing arrangements were found. In the class with lowest energies, the strands of the two beta-sheets are aligned nearly parallel (or antiparallel) with each other, with a preference for a negative orientation angle, because this arrangement corresponds to the best complementary packing of the two twisted saddle-shaped beta-sheets. In the second class, with higher interaction energies, the strands of the two beta-sheets are oriented nearly perpendicular to each other. While the surfaces of the two beta-sheets are not complementary in this arrangement, there is good packing between the corner of one beta-sheet and the interior part of the surface of the other, resulting in a favorable energy of packing. Both classes correspond to frequently observed orientations of beta-sheets in proteins. In proteins, the second class of packing is usually observed when the two beta-sheets are covalently linked, i.e. when a polypeptide strand passes from one beta-sheet to the other, but we have shown here that a large contribution to the stabilization of this packing arrangement arises from noncovalent interactions.

  9. Gross Motor Profile and Its Association with Socialization Skills in Children with Autism Spectrum Disorders.

    Science.gov (United States)

    Pusponegoro, Hardiono D; Efar, Pustika; Soedjatmiko; Soebadi, Amanda; Firmansyah, Agus; Chen, Hui-Ju; Hung, Kun-Long

    2016-12-01

    While social impairment is considered to be the core deficit in children with autism spectrum disorder (ASD), a large proportion of these children have poor gross motor ability, and gross motor deficits may influence socialization skills in children with ASD. The objectives of this study were to compare gross motor skills in children with ASD to typically developing children, to describe gross motor problems in children with ASD, and to investigate associations between gross motor and socialization skills in children with ASD. This was a cross-sectional study including 40 ASD children aged from 18 months to 6 years and 40 age-matched typically developing controls. Gross motor and socialization skills were scored using the Vineland Adaptive Behavior Scales, 2 nd edition (Vineland-II). Below average gross motor function was found in eight of 40 (20%) ASD children. The mean gross motor v-scale score in the ASD group was 15.1 [standard deviation (SD) 3.12], significantly lower than in the control group [18.7, SD 2.09, p = 0.0001; 95% confidence intervals (CI) from -4.725 to -2.525]. The differences were most prominent in ball throwing and catching, using stairs, jumping, and bicycling. The ASD children with gross motor impairments had a mean socialization domain score of 66.6 (SD 6.50) compared to 85.7 (SD 10.90) in those without gross motor impairments (p = 0.0001, 95% CI from -25.327 to -12.736). Children with ASD had lower gross motor skills compared to typically developing children. Gross motor impairments were found in 20% of the ASD children, and these children also had lower socialization skills than those without gross motor impairments. Copyright © 2016. Published by Elsevier B.V.

  10. Gross national happiness as a framework for health impact assessment

    International Nuclear Information System (INIS)

    Pennock, Michael; Ura, Karma

    2011-01-01

    The incorporation of population health concepts and health determinants into Health Impact Assessments has created a number of challenges. The need for intersectoral collaboration has increased; the meaning of 'health' has become less clear; and the distinctions between health impacts, environmental impacts, social impacts and economic impacts have become increasingly blurred. The Bhutanese concept of Gross National Happiness may address these issues by providing an over-arching evidence-based framework which incorporates health, social, environmental and economic contributors as well as a number of other key contributors to wellbeing such as culture and governance. It has the potential to foster intersectoral collaboration by incorporating a more limited definition of health which places the health sector as one of a number of contributors to wellbeing. It also allows for the examination of the opportunity costs of health investments on wellbeing, is consistent with whole-of-government approaches to public policy and emerging models of social progress.

  11. Optimal Bilinear Control of Gross--Pitaevskii Equations

    KAUST Repository

    Hintermü ller, Michael; Marahrens, Daniel; Markowich, Peter A.; Sparber, Christof

    2013-01-01

    A mathematical framework for optimal bilinear control of nonlinear Schrödinger equations of Gross--Pitaevskii type arising in the description of Bose--Einstein condensates is presented. The obtained results generalize earlier efforts found in the literature in several aspects. In particular, the cost induced by the physical workload over the control process is taken into account rather than the often used L^2- or H^1-norms for the cost of the control action. Well-posedness of the problem and existence of an optimal control are proved. In addition, the first order optimality system is rigorously derived. Also a numerical solution method is proposed, which is based on a Newton-type iteration, and used to solve several coherent quantum control problems.

  12. Measurement and Quantification of Gross Human Shoulder Motion

    Directory of Open Access Journals (Sweden)

    Jeremy T. Newkirk

    2013-01-01

    Full Text Available The shoulder girdle plays an important role in the large pointing workspace that humans enjoy. The goal of this work was to characterize the human shoulder girdle motion in relation to the arm. The overall motion of the human shoulder girdle was characterized based on motion studies completed on test subjects during voluntary (natural/unforced motion. The collected data from the experiments were used to develop surface fit equations that represent the position and orientation of the glenohumeral joint for a given humeral pointing direction. These equations completely quantify gross human shoulder girdle motion relative to the humerus. The equations are presented along with goodness-of-fit results that indicate the equations well approximate the motion of the human glenohumeral joint. This is the first time the motion has been quantified for the entire workspace, and the equations provide a reference against which to compare future work.

  13. Labor Absorption and Its Impact on Gross Regional Domestic Product

    Directory of Open Access Journals (Sweden)

    Made Ika Prastyadewi

    2013-12-01

    Full Text Available The objective of this study is to examine the determinants of labor absorption in the trade, hotel and restaurant sector and its impact on Gross Regional Domestic Product/GRDP at Bali Province. This study is important due to the fact that the GRDP in this sector is the highest compared to other sector but the labor absorption is lower than the agriculture sector. This study used panel data comprising 9 regencies/cities at Bali Province in the period 2003-2009 including fixed effect model and simultaneous equation model of Two-Stage Least Square. The results showed that GRDP, working age population, and the minimum wage have positive effect on employment, while the educated unemployment has no significant effect on the employment in the trade, hotel and restaurant sector. In addition, increases in employment and workers productivity have positive and significant effects the GRDP in the trade, hotel and restaurant sector at Bali Province.

  14. Surface deposition measurements of the TMI-2 gross decontamination experiment

    International Nuclear Information System (INIS)

    McIssac, C.V.; Hetzer, D.C.

    1982-01-01

    In order to measure the effectiveness of the gross decontamination experiment (principally a water spray technique) performed in the TMI-2 reactor building, the Technical Information and Examination Program's Radiation and Environment personnel made surface activity measurements before and after the experiment. In conjunction with surface sampling, thermoluminescent dosimeter (TLD) and gamma spectrometry measurements were also performed to distinguish between radiation fields and contamination. The surface sampler used to collect samples from external surfaces within the reactor building is a milling tool having four major components: a 1.27-cm constant-speed drill; a drill support assembly that allows setting sample penetration depth; filter cartridges for intake air purification and sample collection; and an air pump that forces air across the surface being sampled and through the sample filter cartridge

  15. Counting Zero: Rethinking Feminist Epistemologies

    Directory of Open Access Journals (Sweden)

    Xin Liu

    2017-10-01

    Full Text Available This article concerns feminist engagements with epistemologies. Feminist epistemologies have revealed and challenged the exclusions and denigrations at work in knowledge production processes. And yet, the emphasis on the partiality of knowledge and the non-innocence of any subject position also cast doubt on the possibility of feminist political communities. In view of this, it has been argued that the very parameter of epistemology poses limitations for feminism, for it leads to either political paralysis or prescriptive politics that in fact undoes the political of politics. From a different perspective, decolonial feminists argue for radical epistemic disobedience and delinking the move beyond the confines of Western systems of knowledge and its extractive knowledge economy. Nevertheless, the oppositional logic informs both feminist epistemologies and its critiques, which I argue is symptomatic of the epistemic habits of academic feminism. This article ends with a preliminary reconsideration of the question of origin through the figure of zero. It asks whether it might be possible to conceive of feminist epistemologies as performing the task of counting zero – accounting for origin, wholeness, and universality – that takes into account specificities without forfeiting coalition and claims to knowledge.

  16. Leveraging multiple datasets for deep leaf counting

    OpenAIRE

    Dobrescu, Andrei; Giuffrida, Mario Valerio; Tsaftaris, Sotirios A

    2017-01-01

    The number of leaves a plant has is one of the key traits (phenotypes) describing its development and growth. Here, we propose an automated, deep learning based approach for counting leaves in model rosette plants. While state-of-the-art results on leaf counting with deep learning methods have recently been reported, they obtain the count as a result of leaf segmentation and thus require per-leaf (instance) segmentation to train the models (a rather strong annotation). Instead, our method tre...

  17. Expression and autoregulation of transforming growth factor beta receptor mRNA in small-cell lung cancer cell lines

    DEFF Research Database (Denmark)

    Nørgaard, P; Spang-Thomsen, M; Poulsen, H S

    1996-01-01

    In small-cell lung cancer cell lines resistance to growth inhibition by transforming growth factor (TGF)-beta 1, was previously shown to correlate with lack of TGF-beta receptor I (RI) and II (RII) proteins. To further investigate the role of these receptors, the expression of mRNA for RI, RII...... and beta-glycan (RIII) was examined. The results showed that loss of RII mRNA correlated with TGF-beta 1 resistance. In contrast, RI-and beta-glycan mRNA was expressed by all cell lines, including those lacking expression of these proteins. According to Southern blot analysis, the loss of type II m......RNA was not due to gross structural changes in the gene. The effect of TGF-beta 1 on expression of TGF-beta receptor mRNA (receptor autoregulation) was examined by quantitative Northern blotting in four cell lines with different expression of TGF-beta receptor proteins. In two cell lines expressing all three TGF...

  18. Carbohydrate counting for children with diabetes type 1

    Directory of Open Access Journals (Sweden)

    Juanita Mena-Gallego

    2014-12-01

    Full Text Available Type 1 Diabetes Mellitus (DM1 is an endocrine disease with autoimmune bases that mainly affects children and adolescents. It is characterized by progressive loss of beta cells mass to a critical level where the ability to release the insulin, needed for the utilization of glucose by tissues, is affected, triggering microvascular damage, main long-term complication. Short-term complications are diabetic keto-acidosis and, secondary to insulin therapy, the hypoglycemia. Although insulin therapy is the mainstay of treatment, sometimes it is difficult to calculate the proper dosage for precise glycemic control; carbohydrate counting plays an important role here in the optimization of postprandial glycemic levels, which is demonstrated by the correct levels of glycosylated hemoglobin (HbA1c. This review seeks to assess the available scientific evidence on the effectiveness of carbohydrate counting in children with DM1. Search until May 2014 was conducted in PubMed, Trip database, Cochrane and academic Google; three clinical trials performed in individuals under 18 were found. The studies demonstrate effectiveness but the quality is not strong enough. No systematic reviews were found. A more exhaustive search and possibly more clinical trials are needed to be recommended as a technique of metabolic control of Type 1 Diabetes Mellitus in children.

  19. Gross cystic disease fluid protein-15/prolactin-inducible protein as a biomarker for keratoconus disease.

    Directory of Open Access Journals (Sweden)

    Shrestha Priyadarsini

    Full Text Available Keratoconus (KC is a bilateral degenerative disease of the cornea characterized by corneal bulging, stromal thinning, and scarring. The etiology of the disease is unknown. In this study, we identified a new biomarker for KC that is present in vivo and in vitro. In vivo, tear samples were collected from age-matched controls with no eye disease (n = 36 and KC diagnosed subjects (n = 17. Samples were processed for proteomics using LC-MS/MS. In vitro, cells were isolated from controls (Human Corneal Fibroblasts-HCF and KC subjects (Human Keratoconus Cells-HKC and stimulated with a Vitamin C (VitC derivative for 4 weeks, and with one of the three transforming growth factor-beta (TGF-β isoforms. Samples were analyzed using real-time PCR and Western Blots. By using proteomics analysis, the Gross cystic disease fluid protein-15 (GCDFP-15 or prolactin-inducible protein (PIP was found to be the best independent biomarker able to discriminate between KC and controls. The intensity of GCDFP-15/PIP was significantly higher in healthy subjects compared to KC-diagnosed. Similar findings were seen in vitro, using a 3D culture model. All three TGF-β isoforms significantly down-regulated the expression of GCDFP-15/PIP. Zinc-alpha-2-glycoprotein (AZGP1, a protein that binds to PIP, was identified by proteomics and cell culture to be highly regulated. In this study by different complementary techniques we confirmed the potential role of GCDFP-15/PIP as a novel biomarker for KC disease. It is likely that exploring the GCDFP-15/PIP-AZGP1 interactions will help better understand the mechanism of KC disease.

  20. Derivatives of the Incomplete Beta Function

    Directory of Open Access Journals (Sweden)

    Robert J. Boik

    1998-03-01

    Full Text Available The incomplete beta function is defined as where Beta(p, q is the beta function. Dutka (1981 gave a history of the development and numerical evaluation of this function. In this article, an algorithm for computing first and second derivatives of Ix,p,q with respect to p and q is described. The algorithm is useful, for example, when fitting parameters to a censored beta, truncated beta, or a truncated beta-binomial model.