WorldWideScience

Sample records for grip force amplitude

  1. Domo-Grip: functional evaluation and rehabilitation using grip force.

    Science.gov (United States)

    Hewson, David J; Li, Ke; Frerejean, Alexis; Hogrel, Jean-Yves; Duchene, Jacques

    2010-01-01

    Grip force measurement is routinely used to identify pathologies, evaluate muscular function, and as part of rehabilitation. Grip force has also been shown to be a good indicator of the capacity of elderly to live independently owing to its strong relationship with clinical tests such as the Index of Activities of Daily Living. An autonomous, communicant grip-force measurement device is presented in this paper in order to perform grip-force evaluation at home. The Domo-Grip system consists of the Grip-Ball, the Grip-Box, and Grip-Soft. The Grip-Ball measures the pressure resulting from grip force, the Grip-Box serves as the communication hub, while Grip-Soft is an interactive software suite. The Domo-Grip system can be used as part of a home-based rehabilitation, and also for functional evaluation as part of an assessment of the capacity of elderly to live autonomously.

  2. Proximal arm kinematics affect grip force-load force coordination

    OpenAIRE

    Vermillion, Billy C.; Lum, Peter S; Lee, Sang Wook

    2015-01-01

    During object manipulation, grip force is coordinated with load force, which is primarily determined by object kinematics. Proximal arm kinematics may affect grip force control, as proximal segment motion could affect control of distal hand muscles via biomechanical and/or neural pathways. The aim of this study was to investigate the impact of proximal kinematics on grip force modulation during object manipulation. Fifteen subjects performed three vertical lifting tasks that involved distinct...

  3. Proximal arm kinematics affect grip force-load force coordination.

    Science.gov (United States)

    Vermillion, Billy C; Lum, Peter S; Lee, Sang Wook

    2015-10-01

    During object manipulation, grip force is coordinated with load force, which is primarily determined by object kinematics. Proximal arm kinematics may affect grip force control, as proximal segment motion could affect control of distal hand muscles via biomechanical and/or neural pathways. The aim of this study was to investigate the impact of proximal kinematics on grip force modulation during object manipulation. Fifteen subjects performed three vertical lifting tasks that involved distinct proximal kinematics (elbow/shoulder), but resulted in similar end-point (hand) trajectories. While temporal coordination of grip and load forces remained similar across the tasks, proximal kinematics significantly affected the grip force-to-load force ratio (P = 0.042), intrinsic finger muscle activation (P = 0.045), and flexor-extensor ratio (P muscles and the elbow joint cannot fully explain the observed changes, as task-related changes in intrinsic hand muscle activation were greater than in extrinsic hand muscles. Rather, between-task variation in grip force (highest during task 3) appears to contrast to that in shoulder joint velocity/acceleration (lowest during task 3). These results suggest that complex neural coupling between the distal and proximal upper extremity musculature may affect grip force control during movements, also indicated by task-related changes in intermuscular coherence of muscle pairs, including intrinsic finger muscles. Furthermore, examination of the fingertip force showed that the human motor system may attempt to reduce variability in task-relevant motor output (grip force-to-load force ratio), while allowing larger fluctuations in output less relevant to task goal (shear force-to-grip force ratio).

  4. ASSESSMENT OF GRIP FORCE CONTROL IN PATIENTS WITH MUSCULAR DYSTROPHY

    Directory of Open Access Journals (Sweden)

    Gregorij Kurillo

    2004-12-01

    Full Text Available Background. The majority of hand functionality tests are based on qualitative assessment which largely depends on the experience of the therapist. Computer-assisted methods can provide more objective and accurate measurements of the grip force and other parameters related to grasping.Methods. We analysed the grip force control in 12 patients with muscular dystrophy using the tracking system developed. The system consists of a grip-measuring device with endobjects assessing the force applied in different grips. The device was used as input to a tracking task where the patient applied the grip force according to the visual feedback from the computer screen. Each patient performed two tasks which consisted of tracking a ramp and sinus target.Results. We analysed the maximal grip force as assessed in the ramp task and the tracking accuracy of the sinus task. The results are compared among five different grips (cylindrical, lateral, palmar, pinch and spherical grip, applied with dominant and non-dominant hand. The results show no significant difference in tracking accuracy between the dominant and non-dominant hand.Conclusions. The results obtained in tracking the ramp target showed that the method could be used for the assessment of the muscle fatigue, providing quantitative information on muscle capacity. The results of the sinus-tracking task showed that the method can evaluate the grip force control in different types of grips, providing information on hand dexterity, muscle activation patterns or tremor.

  5. Optimal work-rest cycles for an isometric intermittent gripping task as a function of force, posture and grip span.

    Science.gov (United States)

    Eksioglu, Mahmut

    2006-02-10

    The aim of this study was to investigate the maximum acceptable contraction frequencies (i.e. work-rest cycles) for an isometric-intermittent handgrip task as a function of grip span, applied force and shoulder posture using psychophysical and physiological approaches. Twelve healthy males served as subjects. The three grip spans investigated were the optimal, 2 cm narrower than the optimal, and 2 cm wider than the optimal. The grip force levels studied were 15% and 30% of maximum voluntary grip force and the two shoulder postures were 25 degrees flexion and 30 degrees abduction. The psychophysical results indicate that subjects work faster with the narrower grip span at 15% of maximum voluntary grip force level in comparison to working with the optimal and the wider spans. However, when the task required 30% of maximum grip force level, the subjects worked faster with the optimal grip span. These findings were supported by the results of electromyography, heart rate, blood pressure and perceived discomfort. The study suggests that grip span of a tool is an important factor to be considered in predicting optimal work-rest cycles for hand grip tasks, and the optimum setting of grip span of the hand-tool depends on the required task force level. That is, the optimality is relative rather than absolute. In addition, it appears that weaker subjects can work at a higher rate than stronger ones at the same relative force level.

  6. Specific cerebellar regions are related to force amplitude and rate of force development.

    Science.gov (United States)

    Spraker, M B; Corcos, D M; Kurani, A S; Prodoehl, J; Swinnen, S P; Vaillancourt, D E

    2012-01-16

    The human cerebellum has been implicated in the control of a wide variety of motor control parameters, such as force amplitude, movement extent, and movement velocity. These parameters often covary in both movement and isometric force production tasks, so it is difficult to resolve whether specific regions of the cerebellum relate to specific parameters. In order to address this issue, the current study used two experiments and SUIT normalization to determine whether BOLD activation in the cerebellum scales with the amplitude or rate of change of isometric force production or both. In the first experiment, subjects produced isometric pinch-grip force over a range of force amplitudes without any constraints on the rate of force development. In the second experiment, subjects varied the rate of force production, but the target force amplitude remained constant. The data demonstrate that BOLD activation in separate sub-areas of cerebellar regions lobule VI and Crus I/II scales with both force amplitude and force rate. In addition, BOLD activation in cerebellar lobule V and vermis VI was specific to force amplitude, whereas BOLD activation in lobule VIIb was specific to force rate. Overall, cerebellar activity related to force amplitude was located superior and medial, whereas activity related to force rate was inferior and lateral. These findings suggest that specific circuitry in the cerebellum may be dedicated to specific motor control parameters such as force amplitude and force rate.

  7. Effect of object width on precision grip force and finger posture.

    Science.gov (United States)

    Domalain, M; Vigouroux, L; Danion, F; Sevrez, V; Berton, E

    2008-09-01

    This study aimed to define the effect of object width on spontaneous grasp. Participants held objects of various masses (0.75 to 2.25 kg) and widths (3.5 to 9.5 cm) between thumb and index finger. Grip force, maximal grip force and corresponding finger postures were recorded using an embedded force sensor and an optoelectronic system, respectively. Results showed that index finger joints varied to accommodate the object width, whereas thumb posture remained constant across conditions. For a given object mass, grip force increased as a function of object width, although this result is not dictated by the laws of mechanics. Because maximal grip force also increased with object width, we hypothesise that participants maintain a constant ratio between grip force and their maximal grip force at each given width. Altogether we conclude that when the task consists in manipulating objects/tools, the optimal width is different than when maximal force exertions are required.

  8. Control of Precision Grip Force in Lifting and Holding of Low-Mass Objects.

    Directory of Open Access Journals (Sweden)

    Yuichi Hiramatsu

    Full Text Available Few studies have investigated the control of grip force when manipulating an object with an extremely small mass using a precision grip, although some related information has been provided by studies conducted in an unusual microgravity environment. Grip-load force coordination was examined while healthy adults (N = 17 held a moveable instrumented apparatus with its mass changed between 6 g and 200 g in 14 steps, with its grip surface set as either sandpaper or rayon. Additional measurements of grip-force-dependent finger-surface contact area and finger skin indentation, as well as a test of weight discrimination, were also performed. For each surface condition, the static grip force was modulated in parallel with load force while holding the object of a mass above 30 g. For objects with mass smaller than 30 g, on the other hand, the parallel relationship was changed, resulting in a progressive increase in grip-to-load force (GF/LF ratio. The rayon had a higher GF/LF force ratio across all mass levels. The proportion of safety margin in the static grip force and normalized moment-to-moment variability of the static grip force were also elevated towards the lower end of the object mass for both surfaces. These findings indicate that the strategy of grip force control for holding objects with an extremely small mass differs from that with a mass above 30 g. The data for the contact area, skin indentation, and weight discrimination suggest that a decreased level of cutaneous feedback signals from the finger pads could have played some role in a cost function in efficient grip force control with low-mass objects. The elevated grip force variability associated with signal-dependent and internal noises, and anticipated inertial force on the held object due to acceleration of the arm and hand, could also have contributed to the cost function.

  9. Positive force feedback in development of substrate grip in the stick insect tarsus.

    Science.gov (United States)

    Zill, Sasha N; Chaudhry, Sumaiya; Exter, Annelie; Büschges, Ansgar; Schmitz, Josef

    2014-09-01

    The mechanics of substrate adhesion has recently been intensively studied in insects but less is known about the sensorimotor control of substrate engagement. We characterized the responses and motor effects of tarsal campaniform sensilla in stick insects to understand how sensory signals of force could contribute to substrate grip. The tarsi consist of a chain of segments linked by highly flexible articulations. Morphological studies showed that one to four campaniform sensilla are located on the distal end of each segment. Activities of the receptors were recorded neurographically and sensilla were identified by stimulation and ablation of their cuticular caps. Responses were characterized to bending forces and axial loads, muscle contractions and to forces applied to the retractor apodeme (tendon). The tarsal sensilla effectively encoded both the rate and amplitude of loads and muscle forces, but only when movement was resisted. Mechanical stimulation of the receptors produced activation of motor neurons in the retractor unguis and tibial flexor muscles. These findings indicate that campaniform sensilla can provide information about the effectiveness of the leg muscles in generating substrate adherence. They can also produce positive force feedback that could contribute to the development of substrate grip and stabilization of the tarsal chain.

  10. Effects of Sensory Deficit on Phalanx Force Deviation During Power Grip Post Stroke.

    Science.gov (United States)

    Enders, Leah R; Seo, Na Jin

    2017-01-01

    The effect of sensory deficits on power grip force from individual phalanges was examined. The authors found that stroke survivors with sensory deficits (determined by the Semmes-Weinstein monofilament test) gripped with phalanx force directed more tangential to the object surface, than those without, although both groups had similar motor deficits (Chedoke-McMaster and Fugl-Meyer), grip strength, and skin friction. Altered grip force direction elevates risk of finger slippage against the object thus grip loss/object dropping, hindering activities of daily living. Altered grip force direction was associated with altered muscle activation patterns. In summary, the motor impairment level alone may not describe hand motor control in detail. Information about sensory deficits helps elucidate patients' hand motor control with functional relevance.

  11. Force analysis of the rowing stroke employing two differing oar grips.

    Science.gov (United States)

    Bompa, T O; Hebbelinck, M; Van Gheluwe, B

    1985-06-01

    The velocity of the rowing boat appears to depend on the force which the athlete applies at the handle of the oar. Although force is generated by legs, upper body, and arms, the latter are the only limbs which actually transmit and apply the force against the oar. The force output of the arms seem to be a function of the forearm position used by the athlete while gripping the oar. The traditional gripping technique is with the forearms in pronation. This technique was never challenged or scientifically researched to see whatever a modified one might lead to better efficiency. Consequently, the purpose of this investigation was to analyze whether athletes' force output differed if the gripping technique was changed from pronation to a semiprone grip (one arm prone, the other semiprone). Under the specific conditions of this investigation it was demonstrated that the semiprone position was generating greater force output, thus being superior to the classical prone grip.

  12. Anticipatory grip force between 1 and 3g

    Science.gov (United States)

    White, Olivier; Van Loon, ing.. Jack J. W. A.; Thonnard, Jean-Louis; Hermsdorfer, Joachim; Lefevre, Philippe

    One remarkable capacity of utilizing common tools appropriately as soon as we grasp them relies on the ability to determine in advance the grip force (GF) required to handle them in relation to their mechanical properties and the surrounding environment. This anticipatory strategy avoids the uncompressible delays in the feedback system. The predictive control of GF is made possible because the nervous system can learn, store and then select the internal representations of the dynamics of innumerable objects, known as internal models. Beside this flexibility, the nervous system's ability to learn different task dynamics is often limited in classical robotic experiments The environment itself can be profoundly modified in altered gravity or centrifugation. The few studies that investigated motor adaptation in such contexts did not consider the interaction between gravitational phases and even less the transitions across environments. Here, we tested subject's abilities to adapt to levels of gravitational fields generated by a human centrifuge. In Experiment 1, seven subjects performed 4 lifting trials in each gravitational phase (1 to 2.5g and then 2.5 to 1g by steps of 0.5g) with a 0.12 kg instrumented object. In Experiment 2, six subjects performed vertical oscillations of the object during transitions between 1 and 3g (0.5g steps, ascending and descending phases, profile repeated twice). We continuously measured GF, load force (LF) and ambient gravity. We hypothesized that participants were able to predictively adjust GF to the new environment. In Experiment 1, participants adjusted their GF proportionally to gravity and decreased GF across trials within a given gravitational environment. Preload phases decreased over time from 300ms to 50ms irrespective of gravity. We quantified the abilities of participants to switch across environments by subtracting GF recorded in the last trial in the current gravity level from GF during the first trial in the new environment

  13. Using Hand Grip Force as a Correlate of Longitudinal Acceleration Comfort for Rapid Transit Trains.

    Science.gov (United States)

    Guo, Beiyuan; Gan, Weide; Fang, Weining

    2015-07-02

    Longitudinal acceleration comfort is one of the essential metrics used to evaluate the ride comfort of train. The aim of this study was to investigate the effectiveness of using hand grip force as a correlate of longitudinal acceleration comfort of rapid transit trains. In the paper, a motion simulation system was set up and a two-stage experiment was designed to investigate the role of the grip force on the longitudinal comfort of rapid transit trains. The results of the experiment show that the incremental grip force was linearly correlated with the longitudinal acceleration value, while the incremental grip force had no correlation with the direction of the longitudinal acceleration vector. The results also show that the effects of incremental grip force and acceleration duration on the longitudinal comfort of rapid transit trains were significant. Based on multiple regression analysis, a step function model was established to predict the longitudinal comfort of rapid transit trains using the incremental grip force and the acceleration duration. The feasibility and practicably of the model was verified by a field test. Furthermore, a comparative analysis shows that the motion simulation system and the grip force based model were valid to support the laboratory studies on the longitudinal comfort of rapid transit trains.

  14. Temporary threshold shift of vibratory sensation induced by a vibrating handle and its gripping force.

    Science.gov (United States)

    Nishiyama, K; Taoda, K; Yamashita, H; Watanabe, S

    1996-01-01

    This study examines the effect of the force with which a vibrating handle is gripped on the temporary threshold shift of vibratory sensation (TTSv) induced by hand-arm vibration. Six healthy subjects gripped a handle vibrating with a 1.3 octave-band vibration, with a central frequency of 200 Hz and an intensity of 39.2 m/s2. Exposure was for 1 min and 10 min, respectively. Gripping forces for the 1-min exposure were 5 N, 10 N, 40 N and 80 N, respectively, with 0 N push-pull force. Gripping forces for the 10-min exposure were the same as for the 1-min exposure but omitting 80 N. The vibratory sensation threshold at 125 Hz was measured before and after exposure of an exposed fingertip to vibration. The differences measured determine TTSv.t at time t. TTSv.t determines TTSv.0, that is, the temporary threshold shift of vibratory sensation immediately after exposure to vibration according to the estimate made on the basis of the preceding study. The same experimental conditions were repeated 3 times on different days in a soundproof and thermoregulated room. Our findings show that TTSv increases significantly with increasing gripping force. We also determined the quantitative relationships between TTSv.0 and gripping force as described by the equation TTSv.0 = exp(kf x F + Cf). where kt and Cf are constants and F is gripping force. This study revealed the importance of ergonomic design in reducing the force with which a vibrating handle is gripped to prevent an adverse effect of local vibration. The equation devised may help in the quantitative assessment of the effect of reduced gripping force.

  15. Control of grip force and vertical posture while holding an object and being perturbed.

    Science.gov (United States)

    Chen, Bing; Lee, Yun-Ju; Aruin, Alexander S

    2016-11-01

    We investigated motor control perspectives of coordinating maintenance of posture and application of grip force when holding an object and being perturbed. Ten subjects stood on the force platform holding an instrumented object in their dominant hand and were exposed to an external perturbation applied to their shoulders. Task demands were manipulated by positioning a slippery cap on top of the instrumented object. Grip force applied to the object, the object acceleration and the center of pressure (COP) were recorded and analyzed during the time intervals typical for the anticipatory (APA) and compensatory (CPA) components of postural control. Onsets of grip force were seen before the onsets of the COP displacement and initiation of movements of the handheld object during the APA phase of postural control, while the onsets of maximum grip force preceded the maximum COP displacement during the CPA phase. When the task demands increased by holding a handheld object with the slippery cap, subjects tended to generate grip force earlier and of a smaller magnitude; also, the COP displacement in the APA phase was smaller as compared to holding a handheld object only. The outcome provides a foundation for future studies of maintenance of vertical posture in people with impairments of balance and grip force control when holding an object and being perturbed.

  16. Adaptive grip force is modulated by subthalamic beta activity in Parkinson's disease patients

    Directory of Open Access Journals (Sweden)

    Lukas L. Imbach

    2015-01-01

    Conclusion: The time-locked suppression of beta oscillatory activity in the STN is in line with previous reports of beta ERD prior to voluntary movements. Our results show that the STN is involved in anticipatory grip force control in PD patients. The difference in the phasic beta ERD between the two tasks and the reduction of cortico-subthalamic synchronization suggests that qualitatively different neuronal network states are involved in different grip force control tasks.

  17. Automated force controller for amplitude modulation atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Miyagi, Atsushi, E-mail: atsushi.miyagi@inserm.fr, E-mail: simon.scheuring@inserm.fr; Scheuring, Simon, E-mail: atsushi.miyagi@inserm.fr, E-mail: simon.scheuring@inserm.fr [U1006 INSERM, Université Aix-Marseille, Parc Scientifique et Technologique de Luminy, 163 Avenue de Luminy, 13009 Marseille (France)

    2016-05-15

    Atomic Force Microscopy (AFM) is widely used in physics, chemistry, and biology to analyze the topography of a sample at nanometer resolution. Controlling precisely the force applied by the AFM tip to the sample is a prerequisite for faithful and reproducible imaging. In amplitude modulation (oscillating) mode AFM, the applied force depends on the free and the setpoint amplitudes of the cantilever oscillation. Therefore, for keeping the applied force constant, not only the setpoint amplitude but also the free amplitude must be kept constant. While the AFM user defines the setpoint amplitude, the free amplitude is typically subject to uncontrollable drift, and hence, unfortunately, the real applied force is permanently drifting during an experiment. This is particularly harmful in biological sciences where increased force destroys the soft biological matter. Here, we have developed a strategy and an electronic circuit that analyzes permanently the free amplitude of oscillation and readjusts the excitation to maintain the free amplitude constant. As a consequence, the real applied force is permanently and automatically controlled with picoNewton precision. With this circuit associated to a high-speed AFM, we illustrate the power of the development through imaging over long-duration and at various forces. The development is applicable for all AFMs and will widen the applicability of AFM to a larger range of samples and to a larger range of (non-specialist) users. Furthermore, from controlled force imaging experiments, the interaction strength between biomolecules can be analyzed.

  18. The effect of force feedback delay on stiffness perception and grip force modulation during tool-mediated interaction with elastic force fields.

    Science.gov (United States)

    Leib, Raz; Karniel, Amir; Nisky, Ilana

    2015-05-01

    During interaction with objects, we form an internal representation of their mechanical properties. This representation is used for perception and for guiding actions, such as in precision grip, where grip force is modulated with the predicted load forces. In this study, we explored the relationship between grip force adjustment and perception of stiffness during interaction with linear elastic force fields. In a forced-choice paradigm, participants probed pairs of virtual force fields while grasping a force sensor that was attached to a haptic device. For each pair, they were asked which field had higher level of stiffness. In half of the pairs, the force feedback of one of the fields was delayed. Participants underestimated the stiffness of the delayed field relatively to the nondelayed, but their grip force characteristics were similar in both conditions. We analyzed the magnitude of the grip force and the lag between the grip force and the load force in the exploratory probing movements within each trial. Right before answering which force field had higher level of stiffness, both magnitude and lag were similar between delayed and nondelayed force fields. These results suggest that an accurate internal representation of environment stiffness and time delay was used for adjusting the grip force. However, this representation did not help in eliminating the bias in stiffness perception. We argue that during performance of a perceptual task that is based on proprioceptive feedback, separate neural mechanisms are responsible for perception and action-related computations in the brain.

  19. Extraction of time and frequency features from grip force rates during dexterous manipulation.

    Science.gov (United States)

    Mojtahedi, Keivan; Fu, Qiushi; Santello, Marco

    2015-05-01

    The time course of grip force from object contact to onset of manipulation has been extensively studied to gain insight into the underlying control mechanisms. Of particular interest to the motor neuroscience and clinical communities is the phenomenon of bell-shaped grip force rate (GFR) that has been interpreted as indicative of feedforward force control. However, this feature has not been assessed quantitatively. Furthermore, the time course of grip force may contain additional features that could provide insight into sensorimotor control processes. In this study, we addressed these questions by validating and applying two computational approaches to extract features from GFR in humans: 1) fitting a Gaussian function to GFR and quantifying the goodness of the fit [root-mean-square error, (RMSE)]; and 2) continuous wavelet transform (CWT), where we assessed the correlation of the GFR signal with a Mexican Hat function. Experiment 1 consisted of a classic pseudorandomized presentation of object mass (light or heavy), where grip forces developed to lift a mass heavier than expected are known to exhibit corrective responses. For Experiment 2, we applied our two techniques to analyze grip force exerted for manipulating an inverted T-shaped object whose center of mass was changed across blocks of consecutive trials. For both experiments, subjects were asked to grasp the object at either predetermined or self-selected grasp locations ("constrained" and "unconstrained" task, respectively). Experiment 1 successfully validated the use of RMSE and CWT as they correctly distinguished trials with versus without force corrective responses. RMSE and CWT also revealed that grip force is characterized by more feedback-driven corrections when grasping at self-selected contact points. Future work will examine the application of our analytical approaches to a broader range of tasks, e.g., assessment of recovery of sensorimotor function following clinical intervention, interlimb

  20. Effects of Taping on Pain, Grip Strength and Wrist Extension Force in Patients with Tennis Elbow

    Science.gov (United States)

    Shamsoddini, Alireza; Hollisaz, Mohammad Taghi

    2013-01-01

    Background Tennis elbow (TE) is a common musculotendinous degenerative disorder of the extensor origin at the lateral humeral epicondyle. Different modes of treatment are used for management of tennis elbow. Objectives This study investigated the effect of the taping technique (TT) on pain, grip strength and wrist extension force in treatment of tennis elbow. Patients and Methods Thirty patients (16 men /14 women with a mean age of 32.2 years) with tennis elbow of their dominant arm participated in this study. Outcome measures were assessment of pain at the lateral aspect of the elbow, grip strength and wrist extension force before and five to ten minutes after application of elbow tape on the affected and unaffected arms. A Visual Analog Scale was used to assess pain. A dynamometer and a hand-held dynamometer were used for evaluation of grip strength and wrist extension force, respectively. Results Among the variables, significant differences were found in wrist extension forces between effected and unaffected arms (P = 0.02). Changes in grip strength showed statically significant improvements in the affected arm compared to the unaffected arm (P = 0.03). Also, in assessment of pain at the lateral epicondyle, the mean change between affected and unaffected arms was significant, with P = 0.001. Conclusions The taping technique, as applied in this study demonstrates an impressive effect on wrist extension force and grip strength of patients with TE. Elbow taping also reduces pain at the lateral aspect of the elbow in these patients. PMID:24350156

  1. Evaluation of total grip strength and individual finger forces on opposing (A-type) handles among Koreans.

    Science.gov (United States)

    Kong, Yong-Ku; Seo, Min-Tae; Kang, Hyun-Sung

    2014-01-01

    The present study evaluated the effect of grip span on finger forces and defined the best grip span for maximising total grip strength based on the finger forces and subjective discomfort in a static exertion. Five grip spans (45, 50, 55, 60 and 65 mm) of the opposing (A-type) handle shape were tested in this study to measure total grip strength and individual finger force among Korean population. A total of 30 males who participated in this study were asked to exert a maximum grip force with two repetitions, and to report the subjective discomfort experienced between exertions using the Borg's CR-10 scale. The highest grip strength was obtained at 45 mm and 50 mm grip spans. Results also showed that forces of all fingers, except for the middle finger force, significantly differed over the grip spans. The lowest subjective discomfort was observed in the 50 mm grip span. The results might be used as development guidelines for ergonomic opposing (A-type) hand tools for Korean population.

  2. Measurement error in grip and pinch force measurements in patients with hand injuries.

    Science.gov (United States)

    Schreuders, Ton A R; Roebroeck, Marij E; Goumans, Janine; van Nieuwenhuijzen, Johan F; Stijnen, Theo H; Stam, Henk J

    2003-09-01

    There is limited documentation of measurement error of grip and pinch force evaluation methods. The purposes of this study were (1) to determine indexes of measurement error for intraexaminer and interexaminer measurements of grip and pinch force in patients with hand injuries and (2) to investigate whether the measurement error differs between measurements of the injured and noninjured hands and between experienced and inexperienced examiners. The subjects were a consecutive sample of 33 patients with hand injuries who were seen in the Department of Rehabilitation Medicine of Erasmus MC-University Medical Center Rotterdam in the Netherlands. Repeated measurements were taken of grip and pinch force, with a short break of 2 to 3 minutes between sessions. For the grip force in 2 handle positions (distance between handles of 4.6 and 7.2 cm, respectively), tip pinch (with the index finger on top and the thumb below, with the other fingers flexed) and key pinch force (with the thumb on top and the radial side of the index finger below) data were obtained on both hands of the subjects by an experienced examiner and an inexperienced examiner. Intraclass correlation coefficients (ICCs), standard errors of measurement (SEMs), and associated smallest detectable differences (SDDs) were calculated and compared with data from previous studies. The reliability of the measurements was expressed by ICCs between .82 and .97. For grip force measurements (in the second handle position) by the experienced examiner, an SDD of 61 N was found. For tip pinch and key pinch, these values were 12 N and 11 N, respectively. For measurements by the inexperienced examiner, SDDs of 56 N for grip force and 13 N and 18 N for tip pinch and key pinch were found. Based on the SEMs and SDDs, in individual patients only relatively large differences in grip and pinch force measurements can be adequately detected between consecutive measurements. Measurement error did not differ between injured and

  3. Weight-specific anticipatory coding of grip force in human dorsal premotor cortex

    DEFF Research Database (Denmark)

    van Nuenen, Bart F L; Kuhtz-Buschbeck, Johann; Schulz, Christian

    2012-01-01

    ). An additional pre-cue (S1) correctly predicted the weight in 75% of the trials. Participants were asked to use this prior information to prepare for the lift. In the sham condition, grip force showed a consistent undershoot, if the S1 incorrectly prompted the preparation of a light lift. Likewise, an S1...

  4. Grip Force Control Is Dependent on Task Constraints in Children with and without Developmental Coordination Disorder

    Science.gov (United States)

    Law, Sui-Heung; Lo, Sing Kai; Chow, Susanna; Cheing, Gladys L.Y.

    2011-01-01

    Excessive grip force (GF) is often found in children with developmental coordination disorder (DCD). However, their GF control may vary when task constraints are imposed upon their motor performance. This study aimed to investigate how their GF control changes in response to task demands, and to examine their tactile sensitivity. Twenty-one…

  5. Effects of Taping on Pain, Grip Strength and Wrist Extension Force in Patients with Tennis Elbow

    Directory of Open Access Journals (Sweden)

    Alireza Shamsoddini

    2013-09-01

    Full Text Available Background: Tennis elbow (TE is a common musculotendinous degenerative disorder of the extensor origin at the lateral humeral epicondyle. Different modes of treatment are used for management of tennis elbow.Objectives: This study investigated the effect of the taping technique (TT on pain, grip strength and wrist extension force in treatment of tennis elbow.Patients and Methods: Thirty patients (16 men /14 women with a mean age of 32.2 years with tennis elbow of their dominant arm participated in this study. Outcome measures were assessment of pain at the lateral aspect of the elbow, grip strength and wrist extension force before and five to ten minutes after application of elbow tape on the affected and unaffected arms. A Visual Analog Scale was used to assess pain. A dynamometer and a hand-held dynamometer were used for evaluation of grip strength and wrist extension force, respectively.Results: Among the variables, significant differences were found in wrist extension forces between effected and unaffected arms (P = 0.02. Changes in grip strength showed statically significant improvements in the affected arm compared to the unaffected arm (P = 0.03. Also, in assessment of pain at the lateral epicondyle, the mean change between affected and unaffected arms was significant, with P = 0.001.Conclusions: The taping technique, as applied in this study demonstrates an impressive effect on wrist extension force and grip strength of patients with TE. Elbow taping also reduces pain at the lateral aspect of the elbow in these patients.

  6. A simple technique to study embodied language processes: the grip force sensor.

    Science.gov (United States)

    Nazir, Tatjana A; Hrycyk, Lianna; Moreau, Quentin; Frak, Victor; Cheylus, Anne; Ott, Laurent; Lindemann, Oliver; Fischer, Martin H; Paulignan, Yves; Delevoye-Turrell, Yvonne

    2017-02-01

    Research in cognitive neuroscience has shown that brain structures serving perceptual, emotional, and motor processes are also recruited during the understanding of language when it refers to emotion, perception, and action. However, the exact linguistic and extralinguistic conditions under which such language-induced activity in modality-specific cortex is triggered are not yet well understood. The purpose of this study is to introduce a simple experimental technique that allows for the online measure of language-induced activity in motor structures of the brain. This technique consists in the use of a grip force sensor that captures subtle grip force variations while participants listen to words and sentences. Since grip force reflects activity in motor brain structures, the continuous monitoring of force fluctuations provides a fine-grained estimation of motor activity across time. In other terms, this method allows for both localization of the source of language-induced activity to motor brain structures and high temporal resolution of the recorded data. To facilitate comparison of the data to be collected with this tool, we present two experiments that describe in detail the technical setup, the nature of the recorded data, and the analyses (including justification about the data filtering and artifact rejection) that we applied. We also discuss how the tool could be used in other domains of behavioral research.

  7. Role of movement velocity on the magnitude of grip force while lifting an object with touch from the contralateral finger.

    Science.gov (United States)

    Iyengar, Veena; Santos, Marcio J; Aruin, Alexander S

    2009-04-01

    We investigated whether slower velocity of arm movement affects grip-force generation in conditions with the finger touch provided to the wrist of the target arm. Nine subjects performed the task of lifting and transporting an object at slow, intermediate, and fast velocities with a light finger touch from the contralateral arm and without it. There was an effect of velocity of arm movement on grip-force generation in both conditions. However, when the no touch and touch trials performed with similar velocity were matched, the effect of touch on grip-force reduction was statistically significant (p touch conditions and underlines the importance of using a contralateral touch in the performance of activities of daily living. It also points to a possibility of the development of therapeutic advances for the enhancement of grip-force control in patients with neurological impairments.

  8. Quantification of hand and forearm muscle forces during a maximal power grip task.

    Science.gov (United States)

    Goislard de Monsabert, Benjamin; Rossi, Jérémy; Berton, Eric; Vigouroux, Laurent

    2012-10-01

    The aim of this study was to estimate muscle and joint forces during a power grip task. Considering the actual lack of quantification of such internal variables, this information would be essential for sports sciences, medicine, and ergonomics. This study also contributed to the advancement of scientific knowledge concerning hand control during power grip. A specially designed apparatus combining both an instrumented handle and a pressure map was used to record the forces at the hand/handle interface during maximal exertions. Data were processed such that the forces exerted on 25 hand anatomical areas were determined. Joint angles of the five fingers and the wrist were also computed from synchronized kinematic measurements. These processed data were used as input of a hand/wrist biomechanical model, which includes 23 degrees of freedom and 42 muscles to estimate muscle and joint forces. Greater forces were applied on the distal phalanges of the long fingers compared with the middle and the proximal ones. Concomitantly, high solicitations were observed for FDP muscles. A large cocontraction level of extensor muscles was also estimated by the model and confirmed previously reported activities and injuries of extensor muscles related to the power grip. Quantifying hand internal loadings also resulted in new insights into the thumb and the wrist biomechanics. Output muscle tension ratios were all in smaller ranges than the ones reported in the literature. Including wrist and finger interactions in this hand model provided new quantification of muscle load sharing, cocontraction level, and biomechanics of the hand. Such information could complete future investigations concerning handle ergonomics or pathomechanisms of hand musculoskeletal disorders.

  9. Size-weight illusion and anticipatory grip force scaling following unilateral cortical brain lesion.

    Science.gov (United States)

    Li, Yong; Randerath, Jennifer; Goldenberg, Georg; Hermsdörfer, Joachim

    2011-04-01

    The prediction of object weight from its size is an important prerequisite of skillful object manipulation. Grip and load forces anticipate object size during early phases of lifting an object. A mismatch between predicted and actual weight when two different sized objects have the same weight results in the size-weight illusion (SWI), the small object feeling heavier. This study explores whether lateralized brain lesions in patients with or without apraxia alter the size-weight illusion and impair anticipatory finger force scaling. Twenty patients with left brain damage (LBD, 10 with apraxia, 10 without apraxia), ten patients with right brain damage (RBD), and matched control subjects lifted two different-sized boxes in alternation. All subjects experienced a similar size-weight illusion. The anticipatory force scaling of all groups was in correspondence with the size cue: higher forces and force rates were applied to the big box and lower forces and force rates to the small box during the first lifts. Within few lifts, forces were scaled to actual object weight. Despite the lack of significant differences at group level, 5 out of 20 LBD patients showed abnormal predictive scaling of grip forces. They differed from the LBD patients with normal predictive scaling by a greater incidence of posterior occipito-parietal lesions but not by a greater incidence of apraxia. The findings do not support a more general role for the motor-dominant left hemisphere, or an influence of apraxia per se, in the scaling of finger force according to object properties. However, damage in the vicinity of the parietal-occipital junction may be critical for deriving predictions of weight from size.

  10. The impact of unilateral brain damage on anticipatory grip force scaling when lifting everyday objects.

    Science.gov (United States)

    Eidenmüller, S; Randerath, J; Goldenberg, G; Li, Y; Hermsdörfer, J

    2014-08-01

    The scaling of our finger forces according to the properties of manipulated objects is an elementary prerequisite of skilled motor behavior. Lesions of the motor-dominant left brain may impair several aspects of motor planning. For example, limb-apraxia, a tool-use disorder after left brain damage is thought to be caused by deficient recall or integration of tool-use knowledge into an action plan. The aim of the present study was to investigate whether left brain damage affects anticipatory force scaling when lifting everyday objects. We examined 26 stroke patients with unilateral brain damage (16 with left brain damage, ten with right brain damage) and 21 healthy control subjects. Limb apraxia was assessed by testing pantomime of familiar tool-use and imitation of meaningless hand postures. Participants grasped and lifted twelve randomly presented everyday objects. Grip force was measured with help of sensors fixed on thumb, index and middle-finger. The maximum rate of grip force was determined to quantify the precision of anticipation of object properties. Regression analysis yielded clear deficits of anticipation in the group of patients with left brain damage, while the comparison of patient with right brain damage with their respective control group did not reveal comparable deficits. Lesion-analyses indicate that brain structures typically associated with a tool-use network in the left hemisphere play an essential role for anticipatory grip force scaling, especially the left inferior frontal gyrus (IFG) and the premotor cortex (PMC). Furthermore, significant correlations of impaired anticipation with limb apraxia scores suggest shared representations. However, the presence of dissociations, implicates also independent processes. Overall, our findings suggest that the left hemisphere is engaged in anticipatory grip force scaling for lifting everyday objects. The underlying neural substrate is not restricted to a single region or stream; instead it may rely on

  11. The brain adjusts grip forces differently according to gravity and inertia: a parabolic flight experiment.

    Science.gov (United States)

    White, Olivier

    2015-01-01

    In everyday life, one of the most frequent activities involves accelerating and decelerating an object held in precision grip. In many contexts, humans scale and synchronize their grip force (GF), normal to the finger/object contact, in anticipation of the expected tangential load force (LF), resulting from the combination of the gravitational and the inertial forces. In many contexts, GF and LF are linearly coupled. A few studies have examined how we adjust the parameters-gain and offset-of this linear relationship. However, the question remains open as to how the brain adjusts GF regardless of whether LF is generated by different combinations of weight and inertia. Here, we designed conditions to generate equivalent magnitudes of LF by independently varying mass and movement frequency. In a control experiment, we directly manipulated gravity in parabolic flights, while other factors remained constant. We show with a simple computational approach that, to adjust GF, the brain is sensitive to how LFs are produced at the fingertips. This provides clear evidence that the analysis of the origin of LF is performed centrally, and not only at the periphery.

  12. Intra-session and inter-day reliability of forearm surface EMG during varying hand grip forces.

    Science.gov (United States)

    Hashemi Oskouei, Alireza; Paulin, Michael G; Carman, Allan B

    2013-02-01

    Surface electromyography (EMG) is widely used to evaluate forearm muscle function and predict hand grip forces; however, there is a lack of literature on its intra-session and inter-day reliability. The aim of this study was to determine reliability of surface EMG of finger and wrist flexor muscles across varying grip forces. Surface EMG was measured from six forearm flexor muscles of 23 healthy adults. Eleven of these subjects undertook inter-day test-retest. Six repetitions of five randomized isometric grip forces between 0% and 80% of maximum force (MVC) were recorded and normalized to MVC. Intra- and inter-day reliability were calculated through the intraclass correlation coefficient (ICC) and standard error of measurement (SEM). Normalized EMG produced excellent intra-session ICC of 0.90 when repeated measurements were averaged. Intra-session SEM was low at low grip forces, however, corresponding normalized SEM was high (23-45%) due to the small magnitude of EMG signals. This may limit the ability to evaluate finer forearm muscle function and hand grip forces in daily tasks. Combining EMG of functionally related muscles improved intra-session SEM, improving within-subject reliability without taking multiple measurements. Removing and replacing electrodes inter-day produced poor ICC (ICC < 0.50) but did not substantially affect SEM.

  13. Functional corticospinal projections from human supplementary motor area revealed by corticomuscular coherence during precise grip force control.

    Directory of Open Access Journals (Sweden)

    Sophie Chen

    Full Text Available The purpose of the present study was to investigate whether corticospinal projections from human supplementary motor area (SMA are functional during precise force control with the precision grip (thumb-index opposition. Since beta band corticomuscular coherence (CMC is well-accepted to reflect efferent corticospinal transmission, we analyzed the beta band CMC obtained with simultaneous recording of electroencephalographic (EEG and electromyographic (EMG signals. Subjects performed a bimanual precise visuomotor force tracking task by applying isometric low grip forces with their right hand precision grip on a custom device with strain gauges. Concurrently, they held the device with their left hand precision grip, producing similar grip forces but without any precision constraints, to relieve the right hand. Some subjects also participated in a unimanual control condition in which they performed the task with only the right hand precision grip while the device was held by a mechanical grip. We analyzed whole scalp topographies of beta band CMC between 64 EEG channels and 4 EMG intrinsic hand muscles, 2 for each hand. To compare the different topographies, we performed non-parametric statistical tests based on spatio-spectral clustering. For the right hand, we obtained significant beta band CMC over the contralateral M1 region as well as over the SMA region during static force contraction periods. For the left hand, however, beta band CMC was only found over the contralateral M1. By comparing unimanual and bimanual conditions for right hand muscles, no significant difference was found on beta band CMC over M1 and SMA. We conclude that the beta band CMC found over SMA for right hand muscles results from the precision constraints and not from the bimanual aspect of the task. The result of the present study strongly suggests that the corticospinal projections from human SMA become functional when high precision force control is required.

  14. An Overview on Gripping Force Measurement at the Micro and Nano-Scales Using Two-Fingered Microrobotic Systems

    Directory of Open Access Journals (Sweden)

    Mokrane Boudaoud

    2014-03-01

    Full Text Available Two-fingered micromanipulation systems with an integrated force sensor are widely used in robotics to sense and control gripping forces at the micro and nano-scales. They became of primary importance for an efficient manipulation and characterization of highly deformable biomaterials and nanostructures. This paper presents a chronological overview of gripping force measurement using two-fingered micromanipulation systems. The work summarizes the major achievements in this field from the early 90s to the present, focusing in particular on the evolution of measurement technologies regarding the requirements of microrobotic applications. Measuring forces below the microNewton for the manipulation of highly deformable materials, embedding force sensors within microgrippers to increase their dexterity, and reducing the influence of noise to improve the measurement resolution are among the addressed challenges. The paper shows different examples of how these challenges have been addressed. Resolution, operating range and signal/noise ratio of gripping force sensors are reported and compared. A discussion about force measurement technologies and gripping force control is performed and future trends are highlighted.

  15. An Overview on Gripping Force Measurement at the Micro and Nano-scales Using Two-fingered Microrobotic Systems

    Directory of Open Access Journals (Sweden)

    Mokrane Boudaoud

    2014-03-01

    Full Text Available Two-fingered micromanipulation systems with an integrated force sensor are widely used in robotics to sense and control gripping forces at the micro and nano-scales. They became of primary importance for an efficient manipulation and characterization of highly deformable biomaterials and nanostructures. This paper presents a chronological overview of gripping force measurement using two-fingered micromanipulation systems. The work summarizes the major achievements in this field from the early 90s to the present, focusing in particular on the evolution of measurement technologies regarding the requirements of microrobotic applications. Measuring forces below the microNewton for the manipulation of highly deformable materials, embedding force sensors within microgrippers to increase their dexterity, and reducing the influence of noise to improve the measurement resolution are among the addressed challenges. The paper shows different examples of how these challenges have been addressed. Resolution, operating range and signal/noise ratio of gripping force sensors are reported and compared. A discussion about force measurement technologies and gripping force control is performed and future trends are highlighted.

  16. Effects of Anodal Transcranial Direct Current Stimulation on Visually Guided Learning of Grip Force Control

    Directory of Open Access Journals (Sweden)

    Tamas Minarik

    2015-03-01

    Full Text Available Anodal transcranial Direct Current Stimulation (tDCS has been shown to be an effective non-invasive brain stimulation method for improving cognitive and motor functioning in patients with neurological deficits. tDCS over motor cortex (M1, for instance, facilitates motor learning in stroke patients. However, the literature on anodal tDCS effects on motor learning in healthy participants is inconclusive, and the effects of tDCS on visuo-motor integration are not well understood. In the present study we examined whether tDCS over the contralateral motor cortex enhances learning of grip-force output in a visually guided feedback task in young and neurologically healthy volunteers. Twenty minutes of 1 mA anodal tDCS were applied over the primary motor cortex (M1 contralateral to the dominant (right hand, during the first half of a 40 min power-grip task. This task required the control of a visual signal by modulating the strength of the power-grip for six seconds per trial. Each participant completed a two-session sham-controlled crossover protocol. The stimulation conditions were counterbalanced across participants and the sessions were one week apart. Performance measures comprised time-on-target and target-deviation, and were calculated for the periods of stimulation (or sham and during the afterphase respectively. Statistical analyses revealed significant performance improvements over the stimulation and the afterphase, but this learning effect was not modulated by tDCS condition. This suggests that the form of visuomotor learning taking place in the present task was not sensitive to neurostimulation. These null effects, together with similar reports for other types of motor tasks, lead to the proposition that tDCS facilitation of motor learning might be restricted to cases or situations where the motor system is challenged, such as motor deficits, advanced age, or very high task demand.

  17. Frequency adaptation for enhanced radiation force amplitude in dynamic elastography.

    Science.gov (United States)

    Ouared, Abderrahmane; Montagnon, Emmanuel; Kazemirad, Siavash; Gaboury, Louis; Robidoux, André; Cloutier, Guy

    2015-08-01

    In remote dynamic elastography, the amplitude of the generated displacement field is directly related to the amplitude of the radiation force. Therefore, displacement improvement for better tissue characterization requires the optimization of the radiation force amplitude by increasing the push duration and/or the excitation amplitude applied on the transducer. The main problem of these approaches is that the Food and Drug Administration (FDA) thresholds for medical applications and transducer limitations may be easily exceeded. In the present study, the effect of the frequency used for the generation of the radiation force on the amplitude of the displacement field was investigated. We found that amplitudes of displacements generated by adapted radiation force sequences were greater than those generated by standard nonadapted ones (i.e., single push acoustic radiation force impulse and supersonic shear imaging). Gains in magnitude were between 20 to 158% for in vitro measurements on agar-gelatin phantoms, and 170 to 336% for ex vivo measurements on a human breast sample, depending on focus depths and attenuations of tested samples. The signal-to-noise ratio was also improved more than 4-fold with adapted sequences. We conclude that frequency adaptation is a complementary technique that is efficient for the optimization of displacement amplitudes. This technique can be used safely to optimize the deposited local acoustic energy without increasing the risk of damaging tissues and transducer elements.

  18. Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography

    Directory of Open Access Journals (Sweden)

    Hannes Höppner

    2017-05-01

    Full Text Available We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands.

  19. Key Insights into Hand Biomechanics: Human Grip Stiffness Can Be Decoupled from Force by Cocontraction and Predicted from Electromyography

    Science.gov (United States)

    Höppner, Hannes; Große-Dunker, Maximilian; Stillfried, Georg; Bayer, Justin; van der Smagt, Patrick

    2017-01-01

    We investigate the relation between grip force and grip stiffness for the human hand with and without voluntary cocontraction. Apart from gaining biomechanical insight, this issue is particularly relevant for variable-stiffness robotic systems, which can independently control the two parameters, but for which no clear methods exist to design or efficiently exploit them. Subjects were asked in one task to produce different levels of force, and stiffness was measured. As expected, this task reveals a linear coupling between force and stiffness. In a second task, subjects were then asked to additionally decouple stiffness from force at these force levels by using cocontraction. We measured the electromyogram from relevant groups of muscles and analyzed the possibility to predict stiffness and force. Optical tracking was used for avoiding wrist movements. We found that subjects were able to decouple grip stiffness from force when using cocontraction on average by about 20% of the maximum measured stiffness over all force levels, while this ability increased with the applied force. This result contradicts the force–stiffness behavior of most variable-stiffness actuators. Moreover, we found the thumb to be on average twice as stiff as the index finger and discovered that intrinsic hand muscles predominate our prediction of stiffness, but not of force. EMG activity and grip force allowed to explain 72 ± 12% of the measured variance in stiffness by simple linear regression, while only 33 ± 18% variance in force. Conclusively the high signal-to-noise ratio and the high correlation to stiffness of these muscles allow for a robust and reliable regression of stiffness, which can be used to continuously teleoperate compliance of modern robotic hands. PMID:28588472

  20. A method to study precision grip control in viscoelastic force fields using a robotic gripper.

    Science.gov (United States)

    Lambercy, Olivier; Metzger, Jean-Claude; Santello, Marco; Gassert, Roger

    2015-01-01

    Instrumented objects and multipurpose haptic displays have commonly been used to investigate sensorimotor control of grasping and manipulation. A major limitation of these devices, however, is the extent to which the experimenter can vary the interaction dynamics to fully probe sensorimotor control mechanisms. We propose a novel method to study precision grip control using a grounded robotic gripper with two moving, mechanically coupled finger pads instrumented with force sensors. The device is capable of stably rendering virtual mechanical properties with a wide dynamic range of achievable impedances. Eight viscoelastic force fields with different combinations of stiffness and damping parameters were implemented, and tested on eight healthy subjects performing 30 consecutive repetitions of a grasp, hold, and release task with time and position constraints. Rates of thumb and finger force were found to be highly correlated (r>0.9) during grasping, revealing that, despite the mechanical coupling of the two finger pads, subjects performed grasping movements in a physiological fashion. Subjects quickly adapted to the virtual dynamics (within seven trials), but, depending on the presented force field condition, used different control strategies to correctly perform the task. The proof of principle presented in this paper underscores the potential of such a one-degree-of-freedom robotic gripper to study neural control of grasping, and to provide novel insights on sensorimotor control mechanisms.

  1. The application of an external wrist extension force reduces electromyographic activity of wrist extensor muscles during gripping.

    NARCIS (Netherlands)

    Elk, N. van; Faes, M.C.; Degens, H.; Kooloos, J.G.M.; Lint, J.A. de; Hopman, M.T.E.

    2004-01-01

    STUDY DESIGN: Experimental repeated-measures study. OBJECTIVE: To investigate the effect of different extension forces applied to the palm of the hand on electromyographic (EMG) activity of the wrist extensor muscles during hand gripping. BACKGROUND: Lateral epicondylitis is usually caused by repeti

  2. A low cost grip transducer based instrument to quantify fingertip touch force.

    Science.gov (United States)

    Boukhenous, Samir; Attari, Mokhtar

    2007-01-01

    In this paper, a transducer based instrument for fingertip touch force is developed. As a diagnostic tool, the system was coupled with an EMG analog signal processor, which is considered as the main basis of evaluation for motor function impairment. A software program is developed to analyze EMG signal during fingertips effort to obtain valid characteristic parameters with spectral analysis. These parameters are associated with a low cost grip transducer based on Hall Effect component developed for the improvement of fingertip movement during holding objects or training exercises. Thus, the changes on each sensor signal can be detected and monitored with the software interface. The output signal and the EMG analog processor are feeding a high resolution data acquisition system of National Instrument. Preliminary experimental tests have been carried out for the fingertip force grasping according to the Adductor Pollicis muscle (AdP) for controlling the adductive motion of the thumb. The experimental results show that the changes of dynamic fingertip force affect the muscle.

  3. Detailed Study of Amplitude Nonlinearity in Piezoresistive Force Sensors

    OpenAIRE

    Pablo Gonzalez De Santos; Elena Garcia; Luis Emmi; Leonel Paredes-Madrid

    2011-01-01

    This article upgrades the RC linear model presented for piezoresistive force sensors. Amplitude nonlinearity is found in sensor conductance, and a characteristic equation is formulated for modeling its response under DC-driving voltages below 1 V. The feasibility of such equation is tested on four FlexiForce model A201-100 piezoresistive sensors by varying the sourcing voltage and the applied forces. Since the characteristic equation proves to be valid, a method is presented for obtaining a s...

  4. Predictive force programming in the grip-lift task: the role of memory links between arbitrary cues and object weight.

    Science.gov (United States)

    Ameli, Mitra; Dafotakis, Manuel; Fink, Gereon R; Nowak, Dennis A

    2008-01-01

    We tested the ability of healthy participants to learn an association between arbitrary sensory cues and the weight of an object to be lifted using a precision grip between the index finger and thumb. Right-handed participants performed a series of grip-lift tasks with each hand. In a first experiment, participants lifted two objects of equal visual appearance which unexpectedly and randomly changed their weight. In two subsequent experiments, the change in object weight was indicated by cues, which were presented (i) visually or (ii) auditorily. When no cue about the weight of the object to be lifted was presented, participants programmed grip force according to the most recent lift, regardless of the hand used. In contrast, participants were able to rapidly establish an association between a particular sensory cue with a given weight and scaled grip force precisely to the actual weight thereafter, regardless of the hand used or the sensory modality of the cue. We discuss our data within the theoretical concept of internal models.

  5. Detailed Study of Amplitude Nonlinearity in Piezoresistive Force Sensors

    Directory of Open Access Journals (Sweden)

    Pablo Gonzalez De Santos

    2011-09-01

    Full Text Available This article upgrades the RC linear model presented for piezoresistive force sensors. Amplitude nonlinearity is found in sensor conductance, and a characteristic equation is formulated for modeling its response under DC-driving voltages below 1 V. The feasibility of such equation is tested on four FlexiForce model A201-100 piezoresistive sensors by varying the sourcing voltage and the applied forces. Since the characteristic equation proves to be valid, a method is presented for obtaining a specific sensitivity in sensor response by calculating the appropriate sourcing voltage and feedback resistor in the driving circuit; this provides plug-and-play capabilities to the device and reduces the start-up time of new applications where piezoresistive devices are to be used. Finally, a method for bypassing the amplitude nonlinearity is presented with the aim of reading sensor capacitance.

  6. Detailed study of amplitude nonlinearity in piezoresistive force sensors.

    Science.gov (United States)

    Paredes-Madrid, Leonel; Emmi, Luis; Garcia, Elena; de Santos, Pablo Gonzalez

    2011-01-01

    This article upgrades the RC linear model presented for piezoresistive force sensors. Amplitude nonlinearity is found in sensor conductance, and a characteristic equation is formulated for modeling its response under DC-driving voltages below 1 V. The feasibility of such equation is tested on four FlexiForce model A201-100 piezoresistive sensors by varying the sourcing voltage and the applied forces. Since the characteristic equation proves to be valid, a method is presented for obtaining a specific sensitivity in sensor response by calculating the appropriate sourcing voltage and feedback resistor in the driving circuit; this provides plug-and-play capabilities to the device and reduces the start-up time of new applications where piezoresistive devices are to be used. Finally, a method for bypassing the amplitude nonlinearity is presented with the aim of reading sensor capacitance.

  7. Explaining the discrepancy between forced fold amplitude and sill thickness.

    Science.gov (United States)

    Hoggett, Murray; Jones, Stephen M.; Reston, Timothy; Magee, Craig; Jackson, Christopher AL

    2017-04-01

    Understanding the behaviour of Earth's surface in response to movement and emplacement of magma underground is important because it assists calculation of subsurface magma volumes, and could feed into eruption forecasting. Studies of seismic reflection data have observed that the amplitude of a forced fold above an igneous sill is usually smaller than the thickness of the sill itself. This observation implies that fold amplitude alone provides only a lower bound for magma volume, and an understanding of the mechanism(s) behind the fold amplitude/sill thickness discrepancy is also required to obtain a true estimate of magma volume. Mechanisms suggested to explain the discrepancy include problems with seismic imaging and varying strain behaviour of the host rock. Here we examine the extent to which host-rock compaction can explain the fold amplitude/sill thickness discrepancy. This mechanism operates in cases where a sill is injected into the upper few kilometres of sedimentary rock that contain significant porosity. Accumulation of sediment after sill intrusion reduces the amplitude of the forced fold by compaction, but the sill itself undergoes little compaction since its starting porosity is almost zero. We compiled a database of good-quality 2D and 3D seismic observations where sill thickness has been measured independently of forced fold geometry. We then backstripped the post-intrusion sedimentary section to reconstruct the amplitude of the forced fold at the time of intrusion. We used the standard compaction model in which porosity decays exponentially below the sediment surface. In all examples we studied, post-sill-emplacement compaction can explain all of the fold amplitude/sill thickness discrepancy, subject to uncertainty in compaction model parameters. This result leads directly to an improved method of predicting magma volume from fold amplitude, including how uncertainty in compaction parameters maps onto uncertainty in magma volume. Our work implies

  8. Deficient grip force control in schizophrenia: behavioral and modeling evidence for altered motor inhibition and motor noise.

    Science.gov (United States)

    Teremetz, Maxime; Amado, Isabelle; Bendjemaa, Narjes; Krebs, Marie-Odile; Lindberg, Pavel G; Maier, Marc A

    2014-01-01

    Whether upper limb sensorimotor control is affected in schizophrenia and how underlying pathological mechanisms may potentially intervene in these deficits is still being debated. We tested voluntary force control in schizophrenia patients and used a computational model in order to elucidate potential cerebral mechanisms underlying sensorimotor deficits in schizophrenia. A visuomotor grip force-tracking task was performed by 17 medicated and 6 non-medicated patients with schizophrenia (DSM-IV) and by 15 healthy controls. Target forces in the ramp-hold-and-release paradigm were set to 5 N and to 10% maximal voluntary grip force. Force trajectory was analyzed by performance measures and Principal Component Analysis (PCA). A computational model incorporating neural control signals was used to replicate the empirically observed motor behavior and to explore underlying neural mechanisms. Grip task performance was significantly lower in medicated and non-medicated schizophrenia patients compared to controls. Three behavioral variables were significantly higher in both patient groups: tracking error (by 50%), coefficient of variation of force (by 57%) and duration of force release (up by 37%). Behavioral performance did not differ between patient groups. Computational simulation successfully replicated these findings and predicted that decreased motor inhibition, together with an increased signal-dependent motor noise, are sufficient to explain the observed motor deficits in patients. PCA also suggested altered motor inhibition as a key factor differentiating patients from control subjects: the principal component representing inhibition correlated with clinical severity. These findings show that schizophrenia affects voluntary sensorimotor control of the hand independent of medication, and suggest that reduced motor inhibition and increased signal-dependent motor noise likely reflect key pathological mechanisms of the sensorimotor deficit.

  9. The bilateral movement condition facilitates maximal but not submaximal paretic-limb grip force in people with post-stroke hemiparesis

    Science.gov (United States)

    DeJong, Stacey L.; Lang, Catherine E.

    2012-01-01

    Objectives Although healthy individuals have less force production capacity during bilateral muscle contractions compared to unilateral efforts, emerging evidence suggests that certain aspects of paretic upper limb task performance after stroke may be enhanced by moving bilaterally instead of unilaterally. We investigated whether the bilateral movement condition affects grip force differently on the paretic side of people with post-stroke hemiparesis, compared to their non-paretic side and both sides of healthy young adults. Methods Within a single session, we compared: 1) maximal grip force during unilateral vs. bilateral contractions on each side, and 2) force contributed by each side during a 30% submaximal bilateral contraction. Results Healthy controls produced less grip force in the bilateral condition, regardless of side (- 2.4% difference), and similar findings were observed on the non-paretic side of people with hemiparesis (- 4.5% difference). On the paretic side, however, maximal grip force was increased by the bilateral condition in most participants (+11.3% difference, on average). During submaximal bilateral contractions in each group, the two sides each contributed the same percentage of unilateral maximal force. Conclusions The bilateral condition facilitates paretic limb grip force at maximal, but not submaximal levels. Significance In some people with post-stroke hemiparesis, the paretic limb may benefit from bilateral training with high force requirements. PMID:22248812

  10. Molecular dynamics simulation of amplitude modulation atomic force microscopy.

    Science.gov (United States)

    Hu, Xiaoli; Egberts, Philip; Dong, Yalin; Martini, Ashlie

    2015-06-12

    Molecular dynamics (MD) simulations were used to model amplitude modulation atomic force microscopy (AM-AFM). In this novel simulation, the model AFM tip responds to both tip-substrate interactions and to a sinusoidal excitation signal. The amplitude and phase shift of the tip oscillation observed in the simulation and their variation with tip-sample distance were found to be consistent with previously reported trends from experiments and theory. These simulation results were also fit to an expression enabling estimation of the energy dissipation, which was found to be smaller than that in a corresponding experiment. The difference was analyzed in terms of the effects of tip size and substrate thickness. Development of this model is the first step toward using MD to gain insight into the atomic-scale phenomena that occur during an AM-AFM measurement.

  11. Performance of repetitive tasks induces decreased grip strength and increased fibrogenic proteins in skeletal muscle: role of force and inflammation.

    Directory of Open Access Journals (Sweden)

    Samir M Abdelmagid

    Full Text Available BACKGROUND: This study elucidates exposure-response relationships between performance of repetitive tasks, grip strength declines, and fibrogenic-related protein changes in muscles, and their link to inflammation. Specifically, we examined forearm flexor digitorum muscles for changes in connective tissue growth factor (CTGF; a matrix protein associated with fibrosis, collagen type I (Col1; a matrix component, and transforming growth factor beta 1 (TGFB1; an upstream modulator of CTGF and collagen, in rats performing one of two repetitive tasks, with or without anti-inflammatory drugs. METHODOLOGY/RESULTS: To examine the roles of force versus repetition, rats performed either a high repetition negligible force food retrieval task (HRNF, or a high repetition high force handle-pulling task (HRHF, for up to 9 weeks, with results compared to trained only (TR-NF or TR-HF and normal control rats. Grip strength declined with both tasks, with the greatest declines in 9-week HRHF rats. Quantitative PCR (qPCR analyses of HRNF muscles showed increased expression of Col1 in weeks 3-9, and CTGF in weeks 6 and 9. Immunohistochemistry confirmed PCR results, and also showed greater increases of CTGF and collagen matrix in 9-week HRHF rats than 9-week HRNF rats. ELISA, and immunohistochemistry revealed greater increases of TGFB1 in TR-HF and 6-week HRHF, compared to 6-week HRNF rats. To examine the role of inflammation, results from 6-week HRHF rats were compared to rats receiving ibuprofen or anti-TNF-α treatment in HRHF weeks 4-6. Both treatments attenuated HRHF-induced increases in CTGF and fibrosis by 6 weeks of task performance. Ibuprofen attenuated TGFB1 increases and grip strength declines, matching our prior results with anti-TNFα. CONCLUSIONS/SIGNIFICANCE: Performance of highly repetitive tasks was associated with force-dependent declines in grip strength and increased fibrogenic-related proteins in flexor digitorum muscles. These changes were

  12. Dissipation and oscillatory solvation forces in confined liquids studied by small-amplitude atomic force spectroscopy

    NARCIS (Netherlands)

    Beer, de Sissi; Ende, van den Dirk; Mugele, Frieder

    2010-01-01

    We determine conservative and dissipative tip–sample interaction forces from the amplitude and phase response of acoustically driven atomic force microscope (AFM) cantilevers using a non-polar model fluid (octamethylcyclotetrasiloxane, which displays strong molecular layering) and atomically flat su

  13. Design and Evaluation of a Fiber-Optic Grip Force Sensor with Compliant 3D-Printable Structure for (fMRI Applications

    Directory of Open Access Journals (Sweden)

    Tobias L. Bützer

    2016-01-01

    Full Text Available Grip force sensors compatible with magnetic resonance imaging (MRI are used in human motor control and decision-making research, providing objective and sensitive behavioral outcome measures. Commercial sensors are expensive, cover limited force ranges, rely on pneumatic force transmission that cannot detect fast force changes, or are electrically active, which increases the risk of electromagnetic interference. We present the design and evaluation of a low-cost, 3D-printed, inherently MRI-compatible grip force sensor based on a commercial intensity-based fiber-optic sensor. A compliant monobloc structure with flexible hinges transduces grip force to a linear displacement captured by the fiber-optic sensor. The structure can easily be adapted for different force ranges by changing the hinge thickness. A prototype designed for forces up to 800 N was manufactured and showed a highly linear behavior (nonlinearity of 2.37% and an accuracy of 1.57% in a range between zero and 500 N. It can be printed and assembled within one day and for less than $300. Accurate performance was confirmed, both inside and outside a 3 T MRI scanner within a pilot study. Given its simple design allowing for customization of sensing properties and ergonomics for different applications and requirements, the proposed grip force handle offers researchers a valuable scientific tool.

  14. Atomic force microscopy force-distance curves with small amplitude ultrasonic modulation.

    Science.gov (United States)

    Ma, Chengfu; Chen, Yuhang; Wang, Tian; Chu, Jiaru

    2015-01-01

    Force-distance curves were acquired on a highly oriented pyrolytic graphite (HOPG) specimen and a gold film specimen under ultrasonic modulation in atomic force microscopy (AFM). Measurements demonstrated that small amplitude ultrasonic oscillation of either the cantilever or the sample has significant impacts on the characteristics of force-distance curves. With the increase of excitation amplitude, the apparent pull-off force decreased gradually and the hysteresis between the approach and retraction curves reduced significantly. Furthermore, the decrease of the pull-off force was determined to be also relevant to the excitation frequency. With the assistance of contact resonance spectra, the pull-off force was verified to have a near-linear relationship with the cantilever contact oscillation amplitude. Theoretical analysis and subsequent numerical simulations well interpreted the experimental results. The emergence of large oscillating contact forces under ultrasonic modulation altered the force-distance curves, and such a mechanism was ascertained by further ultrasonic AFM imaging. © Wiley Periodicals, Inc.

  15. From Single Motor Unit Activity to Multiple Grip Forces: Mini‐review of Multi‐digit Grasping1

    Science.gov (United States)

    Winges, Sara A.; Santello, Marco

    2007-01-01

    SYNOPSIS This paper is a mini review of kinetic and kinematic evidence on the control of the hand with emphasis on grasping. It is not meant to be an exhaustive review, rather it summarizes current research examining the mechanisms through which specific patterns of coordination are elicited and observed during reach to grasp movements and static grasping. These coordination patterns include the spatial and temporal covariation of the rotation at multiple joints during reach to grasp movements. A basic coordination between grip forces produced by multiple digits also occurs during whole hand grasping such that normal forces tend to be produced in a synchronous fashion across pairs of digits. Finally, we address current research that suggests that motor unit synchrony across hand muscles and muscle compartments might be one of the neural mechanisms underlying the control of grasping. PMID:18414593

  16. Specific cerebellar regions are related to force amplitude and rate of force development

    OpenAIRE

    Spraker, M B.; Corcos, D.M.; Kurani, A.S.; Prodoehl, J; Swinnen, S.P.; Vaillancourt, D E

    2011-01-01

    The human cerebellum has been implicated in the control of a wide variety of motor control parameters, such as force amplitude, movement extent, and movement velocity. These parameters often covary in both movement and isometric force production tasks, so it is difficult to resolve whether specific regions of the cerebellum relate to specific parameters. In order to address this issue, the current study used two experiments and SUIT normalization to determine whether BOLD activation in the ce...

  17. Combining displacement field and grip force information to determine mechanical properties of planar tissue with complicated geometry.

    Science.gov (United States)

    Nagel, Tina M; Hadi, Mohammad F; Claeson, Amy A; Nuckley, David J; Barocas, Victor H

    2014-11-01

    Performing planar biaxial testing and using nominal stress-strain curves for soft-tissue characterization is most suitable when (1) the test produces homogeneous strain fields, (2) fibers are aligned with the coordinate axes, and (3) strains are measured far from boundaries. Some tissue types [such as lamellae of the annulus fibrosus (AF)] may not allow for these conditions to be met due to their natural geometry and constitution. The objective of this work was to develop and test a method utilizing a surface displacement field, grip force-stretch data, and finite-element (FE) modeling to facilitate analysis of such complex samples. We evaluated the method by regressing a simple structural model to simulated and experimental data. Three different tissues with different characteristics were used: Superficial pectoralis major (SPM) (anisotropic, aligned with axes), facet capsular ligament (FCL) (anisotropic, aligned with axes, bone attached), and a lamella from the AF (anisotropic, aligned off-axis, bone attached). We found that the surface displacement field or the grip force-stretch data information alone is insufficient to determine a unique parameter set. Utilizing both data types provided tight confidence regions (CRs) of the regressed parameters and low parameter sensitivity to initial guess. This combined fitting approach provided robust characterization of tissues with varying fiber orientations and boundaries and is applicable to tissues that are poorly suited to standard biaxial testing. The structural model, a set of C++ finite-element routines, and a Matlab routine to do the fitting based on a set of force/displacement data is provided in the on-line supplementary material.

  18. Cross-talk in mechanomyographic signals from the forearm muscles during sub-maximal to maximal isometric grip force.

    Directory of Open Access Journals (Sweden)

    Md Anamul Islam

    Full Text Available PURPOSE: This study aimed: i to examine the relationship between the magnitude of cross-talk in mechanomyographic (MMG signals generated by the extensor digitorum (ED, extensor carpi ulnaris (ECU, and flexor carpi ulnaris (FCU muscles with the sub-maximal to maximal isometric grip force, and with the anthropometric parameters of the forearm, and ii to quantify the distribution of the cross-talk in the MMG signal to determine if it appears due to the signal component of intramuscular pressure waves produced by the muscle fibers geometrical changes or due to the limb tremor. METHODS: Twenty, right-handed healthy men (mean ± SD: age  = 26.7±3.83 y; height  = 174.47±6.3 cm; mass  = 72.79±14.36 kg performed isometric muscle actions in 20% increment from 20% to 100% of the maximum voluntary isometric contraction (MVIC. During each muscle action, MMG signals generated by each muscle were detected using three separate accelerometers. The peak cross-correlations were used to quantify the cross-talk between two muscles. RESULTS: The magnitude of cross-talk in the MMG signals among the muscle groups ranged from, R2(x, y = 2.45-62.28%. Linear regression analysis showed that the magnitude of cross-talk increased linearly (r2 = 0.857-0.90 with the levels of grip force for all the muscle groups. The amount of cross-talk showed weak positive and negative correlations (r2 = 0.016-0.216 with the circumference and length of the forearm respectively, between the muscles at 100% MVIC. The cross-talk values significantly differed among the MMG signals due to: limb tremor (MMGTF, slow firing motor unit fibers (MMGSF and fast firing motor unit fibers (MMGFF between the muscles at 100% MVIC (p<0.05, η2 = 0.47-0.80. SIGNIFICANCE: The results of this study may be used to improve our understanding of the mechanics of the forearm muscles during different levels of the grip force.

  19. Peak forces and lateral resolution in amplitude modulation force microscopy in liquid

    Directory of Open Access Journals (Sweden)

    Horacio V. Guzman

    2013-12-01

    Full Text Available The peak forces exerted on soft and rigid samples by a force microscope have been modeled by performing numerical simulations of the tip motion in liquid. The forces are obtained by using two contact mechanics models, Hertz and Tatara. We present a comparison between the numerical simulations and three analytical models for a wide variety of probe and operational parameters. In general, the forces derived from analytical expressions are not in good quantitative agreement with the simulations when the Young modulus and the set-point amplitude are varied. The only exception is the parametrized approximation that matches the results given by Hertz contact mechanics for soft materials and small free amplitudes. We also study the elastic deformation of the sample as a function of the imaging conditions for materials with a Young modulus between 25 MPa and 2 GPa. High lateral resolution images are predicted by using both small free amplitudes (less than 2 nm for soft materials and high set-point amplitudes.

  20. Grip force and heart rate responses to manual carrying tasks: effects of material, weight, and base area of the container.

    Science.gov (United States)

    Lee, Tzu-Hsien; Tseng, Chia-Yun

    2014-01-01

    This study recruited 16 industrial workers to examine the effects of material, weight, and base area of container on reduction of grip force (ΔGF) and heart rate for a 100-m manual carrying task. This study examined 2 carrying materials (iron and water), 4 carrying weights (4.4, 8.9, 13.3, 17.8 kg), and 2 base areas of container (24 × 24 cm, 35 × 24 cm). This study showed that carrying water significantly increased ΔGF and heart rate as compared with carrying iron. Also, ΔGF and heart rate significantly increased with carrying weight and base area of container. The effects of base area of container on ΔGF and heart rate were greater in carrying water condition than in carrying iron condition. The maximum dynamic effect of water on ΔGF and heart rate occurred when water occupied ~60%-80% of full volume of the container.

  1. Bilateral deficits in fine motor control and pinch grip force are not associated with electrodiagnostic findings in women with carpal tunnel syndrome.

    Science.gov (United States)

    de la Llave-Rincón, Ana Isabel; Fernández-de-Las-Peñas, César; Pérez-de-Heredia-Torres, Marta; Martínez-Perez, Almudena; Valenza, Marie Carmen; Pareja, Juan A

    2011-06-01

    : The aim of this study was to analyze the differences in deficits in fine motor control and pinch grip force between patients with minimal, moderate/mild, or severe carpal tunnel syndrome (CTS) and healthy age- and hand dominance-matched controls. : A case-control study was conducted. The subtests of the Purdue Pegboard Test (one-hand and bilateral pin placements and assemblies) and pinch grip force between the thumb and the remaining four fingers of the hand were bilaterally evaluated in 66 women with minimal (n = 16), moderate (n = 16), or severe (n = 34) CTS and in 20 age- and hand-matched healthy women. The differences among the groups were analyzed using different mixed models of analysis of variance. : A two-way mixed analysis of variance revealed significant differences between groups, not depending on the presence of unilateral or bilateral symptoms (side), for the one-hand pin placement subtest: patients showed bilateral lower scores compared with controls (P < 0.001), without differences among those with minimal, moderate, or severe CTS (P = 0.946). The patients also exhibited lower scores in bilateral pin placement (P < 0.001) and assembly (P < 0.001) subtests, without differences among them. The three-way analysis of variance revealed significant differences among groups (P < 0.001) and fingers (P < 0.001), not depending on the presence of unilateral/bilateral symptoms (P = 0.684), for pinch grip force: patients showed bilateral lower pinch grip force in all fingers compared with healthy controls, without differences among those with minimal, moderate, or severe CTS. : The current study revealed similar bilateral deficits in fine motor control and pinch grip force in patients with minimal, moderate, or severe CTS, supporting that fine motor control deficits are a common feature of CTS not associated with electrodiagnostic findings.

  2. GRIPS Plan

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-31

    The GRIPS (Geothermal Resources Impact Projection Study) Commission was established by a Joint Powers Agreement between the California Counties of Lake, Mendocino, Napa, and Sonoma. The objectives of GRIPS are primarily to develop and use a cooperative environmental data collection and use system including natural, social, and economic considerations to facilitate their independent decisions and those of State and Federal agencies related to the environmental effects of geothermal development. This GRIPS Plan was prepared from a wide range of studies, workshops, and staff analyses. The plan is presented in four parts: summary and introduction; environmental data status report; planned programs; and budget. (MHR)

  3. GRIPS bibliography

    Energy Technology Data Exchange (ETDEWEB)

    1978-07-31

    This GRIPS (Geothermal Resources Impact Project Study) contains over 1700 references on a wide variety of subjects dealing directly or indirectly with geothermal development at the Geysers/Calistoga KGRA. (MHR)

  4. Serotonin and Histamine Therapy Increases Tetanic Forces of Myoblasts, Reduces Muscle Injury, and Improves Grip Strength Performance of Dmdmdx Mice

    Directory of Open Access Journals (Sweden)

    Volkan Gurel

    2015-11-01

    Full Text Available Duchenne muscular dystrophy (DMD is a recessive X-linked fatal disorder caused by a mutation in the dystrophin gene. Although several therapeutic approaches have been studied, none has led to substantial long-term effects in patients. The aim of this study was to test a serotonin and histamine (S&H combination on human skeletal myoblasts and Dmdmdx mice for its effects on muscle strength and injury. Normal human bioartificial muscles (BAMs were treated, and muscle tetanic forces and muscle injury tests were performed using the MyoForce Analysis System. Dmdmdx mice, the murine model of DMD, were administered serotonin, histamine, or S&H combination twice daily for 6 weeks, and functional performance tests were conducted once a week. The S&H combination treatment caused significant increases in tetanic forces at all time points and concentrations tested as compared to the saline controls. Dose response of the BAMs to the treatment demonstrated a significant increase in force generation at all concentrations compared to the controls after 3 to 4 days of drug treatment. The highest 3 concentrations had a significant effect on lowering contractile-induced injury as measured by a reduction in the release of adenylate kinase. Histamine-only and S&H treatments improved grip strength of Dmdmdx mice, whereas serotonin-only treatment resulted in no significant improvement in muscle strength. The results of this study indicate that S&H therapy might be a promising new strategy for muscular dystrophies and that the mechanism should be further investigated.

  5. Grip and limb force limits to turning performance in competition horses

    Science.gov (United States)

    Tan, Huiling; Wilson, Alan M.

    2011-01-01

    Manoeuverability is a key requirement for successful terrestrial locomotion, especially on variable terrain, and is a deciding factor in predator–prey interaction. Compared with straight-line running, bend running requires additional leg force to generate centripetal acceleration. In humans, this results in a reduction in maximum speed during bend running and a published model assuming maximum limb force as a constraint accurately predicts how much a sprinter must slow down on a bend given his maximum straight-line speed. In contrast, greyhounds do not slow down or change stride parameters during bend running, which suggests that their limbs can apply the additional force for this manoeuvre. We collected horizontal speed and angular velocity of heading of horses while they turned in different scenarios during competitive polo and horse racing. The data were used to evaluate the limits of turning performance. During high-speed turns of large radius horizontal speed was lower on the bend, as would be predicted from a model assuming a limb force limit to running speed. During small radius turns the angular velocity of heading decreased with increasing speed in a manner consistent with the coefficient of friction of the hoof–surface interaction setting the limit to centripetal force to avoid slipping. PMID:21147799

  6. Grip and limb force limits to turning performance in competition horses.

    Science.gov (United States)

    Tan, Huiling; Wilson, Alan M

    2011-07-22

    Manoeuverability is a key requirement for successful terrestrial locomotion, especially on variable terrain, and is a deciding factor in predator-prey interaction. Compared with straight-line running, bend running requires additional leg force to generate centripetal acceleration. In humans, this results in a reduction in maximum speed during bend running and a published model assuming maximum limb force as a constraint accurately predicts how much a sprinter must slow down on a bend given his maximum straight-line speed. In contrast, greyhounds do not slow down or change stride parameters during bend running, which suggests that their limbs can apply the additional force for this manoeuvre. We collected horizontal speed and angular velocity of heading of horses while they turned in different scenarios during competitive polo and horse racing. The data were used to evaluate the limits of turning performance. During high-speed turns of large radius horizontal speed was lower on the bend, as would be predicted from a model assuming a limb force limit to running speed. During small radius turns the angular velocity of heading decreased with increasing speed in a manner consistent with the coefficient of friction of the hoof-surface interaction setting the limit to centripetal force to avoid slipping.

  7. Rating forces grip and driving and accelerations of the car with drive different configuration

    Directory of Open Access Journals (Sweden)

    Kowalski Mariusz

    2015-12-01

    Full Text Available The paper shows a typical drive systems used in today's vehicles, mainly cars. Approximated scheme of the formation of the driving force of the vehicle and the necessary mathematical relations for the calculation. For example, a typical passenger car BMW 320 was analyzed and calculations obtained a driving force, of adhesion and acceleration. The calculations were performed for the drive system, the classical (i.e. the rear axle of the vehicle for front-wheel drive and four-wheel drive (4×4. Virtually assumed that to the above mentioned vehicle it is possible buildings of each of said system. These are shown graphically in diagrams bearing a distribution of the forces acting on the substrate and the reactions - the data necessary for the calculations. The resulting calculation is graphically shown in the diagrams, in which is illustrated a change value of the resulting adhesive strength, and the acceleration depending on the drive type vehicle.

  8. Evaluation of pliers' grip spans in the maximum gripping task and sub-maximum cutting task.

    Science.gov (United States)

    Kim, Dae-Min; Kong, Yong-Ku

    2016-12-01

    A total of 25 males participated to investigate the effects of the grip spans of pliers on the total grip force, individual finger forces and muscle activities in the maximum gripping task and wire-cutting tasks. In the maximum gripping task, results showed that the 50-mm grip span had significantly higher total grip strength than the other grip spans. In the cutting task, the 50-mm grip span also showed significantly higher grip strength than the 65-mm and 80-mm grip spans, whereas the muscle activities showed a higher value at 80-mm grip span. The ratios of cutting force to maximum grip strength were also investigated. Ratios of 30.3%, 31.3% and 41.3% were obtained by grip spans of 50-mm, 65-mm, and 80-mm, respectively. Thus, the 50-mm grip span for pliers might be recommended to provide maximum exertion in gripping tasks, as well as lower maximum-cutting force ratios in the cutting tasks.

  9. The Effectiveness of Manual Therapy Versus Surgery on Self-reported Function, Cervical Range of Motion, and Pinch Grip Force in Carpal Tunnel Syndrome: A Randomized Clinical Trial.

    Science.gov (United States)

    Fernández-de-Las-Peñas, César; Cleland, Joshua; Palacios-Ceña, María; Fuensalida-Novo, Stella; Pareja, Juan A; Alonso-Blanco, Cristina

    2017-03-01

    Study Design Randomized parallel-group trial. Background Carpal tunnel syndrome (CTS) is a common pain condition that can be managed surgically or conservatively. Objective To compare the effectiveness of manual therapy versus surgery for improving self-reported function, cervical range of motion, and pinch-tip grip force in women with CTS. Methods In this randomized clinical trial, 100 women with CTS were randomly allocated to either a manual therapy (n = 50) or a surgery (n = 50) group. The primary outcome was self-rated hand function, assessed with the Boston Carpal Tunnel Questionnaire. Secondary outcomes included active cervical range of motion, pinch-tip grip force, and the symptom severity subscale of the Boston Carpal Tunnel Questionnaire. Patients were assessed at baseline and 1, 3, 6, and 12 months after the last treatment by an assessor unaware of group assignment. Analysis was by intention to treat, with mixed analyses of covariance adjusted for baseline scores. Results At 12 months, 94 women completed the follow-up. Analyses showed statistically significant differences in favor of manual therapy at 1 month for self-reported function (mean change, -0.8; 95% confidence interval [CI]: -1.1, -0.5) and pinch-tip grip force on the symptomatic side (thumb-index finger: mean change, 2.0; 95% CI: 1.1, 2.9 and thumb-little finger: mean change, 1.0; 95% CI: 0.5, 1.5). Improvements in self-reported function and pinch grip force were similar between the groups at 3, 6, and 12 months. Both groups reported improvements in symptom severity that were not significantly different at all follow-up periods. No significant changes were observed in pinch-tip grip force on the less symptomatic side and in cervical range of motion in either group. Conclusion Manual therapy and surgery had similar effectiveness for improving self-reported function, symptom severity, and pinch-tip grip force on the symptomatic hand in women with CTS. Neither manual therapy nor surgery resulted

  10. Four Weeks of finger grip training increases the rate of force development and the maximal force in elite and world-top ranking climbers.

    Science.gov (United States)

    Levernier, Guillaume; Laffaye, Guillaume

    2017-09-19

    The goal of this study was to assess the impact of a specific four-week training program on finger grip in climbers; specifically, on the maximal force and the rate of force development (RFD) of finger muscles in isometric contraction. The participants were 14 French male rock climbers who took part in national and international bouldering competitions (at world-ranking and elite levels). They were divided into two samples. The experimental group performed a specific four-week training program that included such exercises as suspensions on small holds at the rate of three times a week. The control group performed climbing exercises only. The maximal force and the RFD were recorded using a specific dynamometer in three different holding conditions (slope crimp, half crimp and full crimp). Results reveal a significant gain of force for the slope crimp (+ 8 %) and a high increase of the RFD in the first 200ms of the force-time slope (between 27.5 % and 32 % for averaged conditions), suggesting a neural gain rather a change in muscle-tendon structure. These results reveals that a four-week training program is enough to improve the level of maximum force and rate of force development in elite climbers. Bearing in mind that climbing will make its appearance in a future Olympic Games in the form of a combined competition, i.e., bouldering, speed climbing and lead climbing, it will be crucial for each athlete to develop both a high level of force and RFD to be competitive.

  11. Effect of combined variation of force amplitude and rate of force development on the modulation characteristics of muscle activation during rapid isometric aiming force production.

    Science.gov (United States)

    Park, Jin-Hoon; Stelmach, George E

    2006-01-01

    Studies of rapid target-directed limb movements have suggested that various control schemes can be defined by the modulation pattern of the muscle activity. The present study was aimed to address the question regarding the extent to which a simultaneous control of force amplitude, and rate of force development influences the modulation characteristics of muscle activation associated with producing rapid isometric aiming forces at the elbow joint. The subjects were instructed to produce rapid isometric force pulses to three different force amplitudes (15, 35, and 55% of their maximal voluntary contractions) under systematically varied force-rate conditions ranging from a fast and accurate force-rate to the fastest force-rate possible. The results showed that larger force amplitudes were achieved by increasing the rate of force development (d F/d t) while the time to peak force remained relatively constant. The magnitude of the electromyographic (EMG) burst systematically increased as a function of force amplitude at all force-rate conditions. The primary finding was that the characteristic of the EMG burst duration associated with different force amplitudes showed a significant difference among force-rate conditions. Under a fast and accurate force-rate condition, the duration of the agonist burst increased linearly with force amplitude. A gradual transition into a fixed duration of the agonist burst then was observed over the remaining three force-rate requirements. With increasingly faster force-rates, there were no changes in the agonist burst duration over three force amplitudes. These results indicate that the combined variations in force amplitude and force-rate examined relative to the most rapid force-rate influence the control patterns for the muscle activation during the fast isometric force production. Changes in the EMG modulation patterns observed are likely due to the constraints imposed by muscle contractile properties.

  12. Large amplitude forced vibration analysis of cross-beam system ...

    African Journals Online (AJOL)

    user

    governing nonlinear differential equation of dynamic equilibrium for forced vibration of a ...... ω is the first natural frequency of the corresponding beam. ..... Although a separate free vibration analysis of the system is not carried out in course.

  13. Hydraulically Driven Grips For Hot Tensile Specimens

    Science.gov (United States)

    Bird, R. Keith; Johnson, George W.

    1994-01-01

    Pair of grips for tensile and compressive test specimens operate at temperatures up to 1,500 degrees F. Grips include wedges holding specimen inside furnace, where heated to uniform temperature. Hydraulic pistons drive wedges, causing them to exert clamping force. Hydraulic pistons and hydraulic fluid remain outside furnace, at room temperature. Cooling water flows through parts of grips to reduce heat transferred to external components. Advantages over older devices for gripping specimens in high-temperature tests; no need to drill holes in specimens, maintains constant gripping force on specimens, and heated to same temperature as that of specimen without risk of heating hydraulic fluid and acuator components.

  14. Motor cortical function and the precision grip.

    Science.gov (United States)

    Geevasinga, Nimeshan; Menon, Parvathi; Kiernan, Matthew C; Vucic, Steve

    2014-12-01

    While task-dependent changes in motor cortical outputs have been previously reported, the issue of whether such changes are specific for complex hand tasks remains unresolved. The aim of the present study was to determine whether cortical inhibitory tone and cortical output were greater during precision grip and power grip. Motor cortex excitability was undertaken by using the transcranial magnetic stimulation threshold tracking technique in 15 healthy subjects. The motor-evoked potential (MEP) responses were recorded over the abductor pollicis brevis (APB), with the hand in the following positions: (1) rest, (2) precision grip and (3) power grip. The MEP amplitude (MEP amplitude REST 23.6 ± 3.3%; MEP amplitude PRECISION GRIP 35.2 ± 5.6%; MEP amplitude POWER GRIP 19.6 ± 3.4%, F = 2.4, P < 0.001) and stimulus-response gradient (SLOPEREST 0.06 ± 0.01; SLOPEPRCISION GRIP 0.15 ± 0.04; SLOPE POWER GRIP 0.07 ± 0.01, P < 0.05) were significantly increased during precision grip. Short interval intracortical inhibition (SICI) was significantly reduced during the precision grip (SICI REST 15.0 ± 2.3%; SICI PRECISION GRIP 9.7 ± 1.5%, SICI POWER GRIP 15.9 ± 2.7%, F = 2.6, P < 0.05). The present study suggests that changes in motor cortex excitability are specific for precision grip, with functional coupling of descending corticospinal pathways controlling thumb and finger movements potentially forming the basis of these cortical changes.

  15. Amplitude modulated Lorentz force MEMS magnetometer with picotesla sensitivity

    Science.gov (United States)

    Kumar, Varun; Ramezany, Alireza; Mahdavi, Mohammad; Pourkamali, Siavash

    2016-10-01

    This paper demonstrates ultra-high sensitivities for a Lorentz force resonant MEMS magnetometer enabled by internal-thermal piezoresistive vibration amplification. A detailed model of the magneto-thermo-electro-mechanical internal amplification is described and is in good agreement with the experimental results. Internal amplification factors up to ~1620 times have been demonstrated by artificially boosting the effective quality factor of the resonator from 680 to 1.14  ×  106 by tuning the bias current. The increase in the resonator bias current in addition to the improvement in the quality factor of the device led to a sensitivity enhancement by ~2400 times. For a bias current of 7.245 mA, where the effective quality factor of the device and consequently the sensitivity is maximum (2.107 mV nT-1), the noise floor is measured to be as low as 2.8 pT (√Hz)-1. This is by far the most sensitive Lorentz force MEMS magnetometer demonstrated to date.

  16. [Reliability and validity of the analysis of hand grip and pinch force in isometric and isokinetic conditions].

    Science.gov (United States)

    Benaglia, P G; Franchignoni, F; Ferriero, G; Zebellin, G; Sartorio, F

    1999-01-01

    Strength measurement of the hand grip is at the core of most protocols of functional assessment of the upper limb and in rehabilitation plays a major role in the analysis of treatment efficacy and patients' occupational ability. The aims of this study were to: a) verify the repeatability of strength measurements made during performance of the hand grip and three types of pinch, carried out under isometric and isokinetic conditions; b) compare maximal isometric strength with the corresponding isokinetic value for each of the manoeuvres studied; c) investigate the correlations between the strength expressed in the different manoeuvres, under both isometric and isokinetic conditions. We studied 14 voluntary subjects over three sessions conducted at 48-hr intervals, employing a computerized isokinetic dynamometer Lido WorkSet equipped with device N(o) 21 for the study of pinch (lateral pinch, pulp pinch, chuck pinch) and device N(o) 52 for the grip study. Isometric contractions resulted stronger than isokinetic ones, and the hand grip was found to be the manoeuvre able to produce most strength. The repeatability of each strength measurement test over the three days was high (Intraclass Correlation Coefficients: 0.89-0.93). Correlations between the isometric and isokinetic performance for each of the manoeuvres examined were always high (Pearson's r coefficients: 0.89-0.95) as were those between the different manoeuvres, whether performed in isometric or isokinetic modality (r: 0.60-0.94).

  17. Short Term Microgravity Effect on Isometric Hand Grip and Precision Pinch Force with Visual and Propioceptive Feedback

    Science.gov (United States)

    Pastacaldi, P.; Bracciaferri, F.; Neri, G.; Porciani, M.; Zolesi, V.

    Experiments executed on the upper limb are assuming increasing significance in the frame of the Human Physiology in space, for at least two reasons: -the upper limb is the principal means of locomotion for the subject living in aspace station -fatigue can have a significant effect the hand, for the ordinary work on board,and in particular for the extra-vehicular activities. The degradation of the performances affecting the muscular-skeletal apparatus can be easily recognized on the upper limb, by exerting specific scientific protocols, to be repeated through the permanence of the subject in weightlessness conditions. Also, the effectiveness of adequate counter-measures aimed to the reduction of calcium and muscular mass need to be verified, by means of specific assessments on the upper limb. Another aspect relevant to the effect of microgravity on the upper limb is associated with the alteration of the motor control programs due to the different gravity factor, affecting not only the bio-mechanics of the subject, but in general all his/her psycho- physical conditions, induced by the totally different environment. Specific protocols on the upper limb can facilitate the studies on learning mechanisms for the motor control. The results of such experiments can be transferred to the Earth, useful for treatment of subjects with local traumas or diseases of the Central Nervous System.In the frame of the mission of the Italian astronaut Roberto Vittori on board the International Space Station (ISS), the Italian Space Agency (ASI) has promoted the program "Marco Polo", with a number of experiments devoted to the study of the effect of microgravity on the human body. The experiment CHIRO ("Crew's Health: Investigation on Reduced Operability) is a part of the program. Its purpose is the determination of the influence of the altered gravity on the control of the grip force exerted by the hand or by a group of fingers and the adaptive behavior of this control through the

  18. Effects of amplitude and phase-duration modification on electrically induced contraction force and discomfort.

    Science.gov (United States)

    Springer, Shmuel; Shapiro, Maxim

    2017-08-09

    Neuromuscular electrical stimulation (NMES) is commonly used in rehabilitation. However, the optimal combination of phase-duration and amplitude for enhancing motor output is not yet resolved. To test the effects of increasing phase-duration and amplitude on isometric knee extension force and discomfort, while controlling the effects of electrode-skin resistance and body mass index (BMI). Twenty-one healthy volunteers participated in the study. Stimulation was set at 250 μsec phase-duration and 45 Hz to evoke 10% of maximal voluntary isometric contraction of the quadriceps. Electrode-skin resistance was measured. Then, electrically induced contraction (EIC) forces and discomfort level were measured under four conditions: Moderate (25%) or substantial increase (50%) from baseline amplitude with constant phase-duration and moderate (25%) or substantial increase (50%) in phase-duration with amplitude constant. Compared with baseline, EIC force was significantly higher in all intensification conditions, while discomfort was significantly greater in all conditions except for moderate increase in phase-duration (p= 0.44). Amplitude intensification produced significantly higher force and greater discomfort than phase-duration. Electrode-skin resistance and BMI were not significant covariates. Greater force is elicited by increasing amplitude than by similar increase in phase-duration; however, the associated discomfort is also higher. Clinicians may use phase-duration while conditioning for NMES.

  19. Analysis of the pen pressure and grip force signal during basic drawing tasks: The timing and speed changes impact drawing characteristics.

    Science.gov (United States)

    Gatouillat, Arthur; Dumortier, Antoine; Perera, Subashan; Badr, Youakim; Gehin, Claudine; Sejdić, Ervin

    2017-08-01

    Writing is a complex fine and trained motor skill, involving complex biomechanical and cognitive processes. In this paper, we propose the study of writing kinetics using three angles: the pen-tip normal force, the total grip force signal and eventually writing quality assessment. In order to collect writing kinetics data, we designed a sensor collecting these characteristics simultaneously. Ten healthy right-handed adults were recruited and were asked to perform four tasks: first, they were instructed to draw circles at a speed they considered comfortable; they then were instructed to draw circles at a speed they regarded as fast; afterwards, they repeated the comfortable task compelled to follow the rhythm of a metronome; and eventually they performed the fast task under the same timing constraints. Statistical differences between the tasks were computed, and while pen-tip normal force and total grip force signal were not impacted by the changes introduced in each task, writing quality features were affected by both the speed changes and timing constraint changes. This verifies the already-studied speed-accuracy trade-off and suggest the existence of a timing constraints-accuracy trade-off. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. The πN amplitude and the three-nucleon force

    Science.gov (United States)

    Afnan, I. R.; Saito, T.-Y.

    1995-05-01

    We examine the role of the energy dependence of the πN amplitude on the π-π three-nucleon force. We find that the inclusion of the full energy dependence reduces the magnitude of the three-nucleon force as a result of the cancellation between the S- and P-wave πN contributions.

  1. Derivation of amplitude equations for nonlinear oscillators subject to arbitrary forcing.

    Science.gov (United States)

    Mayol, Catalina; Toral, Raúl; Mirasso, Claudio R

    2004-06-01

    By using a generalization of the multiple scales technique we develop a method to derive amplitude equations for zero-dimensional forced systems. The method allows to consider either additive or multiplicative forcing terms and can be straightforwardly applied to the case that the forcing is white noise. We give examples of the use of this method to the case of the van der Pol-Duffing oscillator. The writing of the amplitude equations in terms of a Lyapunov potential allow us to obtain an analytical expression for the probability distribution function which reproduces reasonably well the numerical simulation results.

  2. Effects of Periodic Forcing Amplitude on the Spiral Wave Resonance Drift

    Institute of Scientific and Technical Information of China (English)

    WU Ning-Jie; LI Bing-Wei; YING He-Ping

    2006-01-01

    @@ We study dynamics of spiral waves under a uniform periodic temporal forcing in an excitable medium. With a specific combination of frequency and amplitude of the external periodic forcing, a resonance drift of a spiral wave occurs along a straight line, and it is accompanied by a complicated ‘flower-like’ motion on each side of this bifurcate boundary line. It is confirmed that the straight-line drift frequency of spiral waves is not locked to the nature rotation frequency as the forcing amplitude expends the range of the spiral wave frequency. These results are further verified numerically for a simplified kinematical model.

  3. The {pi}{ital N} amplitude and the three-nucleon force

    Energy Technology Data Exchange (ETDEWEB)

    Afnan, I.R. [School of Physical Sciences, Flinders University of South Australia, GPO Box 2100, Adelaide 5001 (Australia); Saito, T. [Institute de Physique Nucleaire, Division de Physique Theorique, 91406 Orsay, Cedex (France)

    1995-05-10

    We examine the role of the energy dependence of the {pi}{ital N} amplitude on the {pi}-{pi} three-nucleon force. We find that the inclusion of the full energy dependence reduces the magnitude of the three-nucleon force as a result of the cancellation between the {ital S}- and {ital P}-wave {pi}{ital N} contributions. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  4. Vibration amplitude of a tip-loaded quartz tuning fork during shear force microscopy scanning

    Science.gov (United States)

    Sandoz, P.; Friedt, J.-M.; Carry, É.

    2008-08-01

    This Note reports on experimental results obtained with a recently published vision method for in-plane vibration measurement [Sandoz et al., Rev. Sci. Instrum. 78, 023706 (2007)]. The latter is applied to a tip-loaded quartz tuning fork frequently used in scanning probe microscopy for shear-force monitoring of the tip-sample distance. The vibration amplitude of the tip-loaded prong is compared to that of the free one and the damping induced by tip-surface interactions is measured. The tuning-fork behavior is characterized during approaches from free space to surface contact. Tip-surface contact is clearly identified by a drastic reduction in the prong vibration amplitude. However, no differences were observed between hydrophilic and hydrophobic surfaces. Experiments reported here show that the vibration amplitude of the quartz tuning fork in free space is a good estimate of the vibration amplitude of the tip interacting with the sample surface during shear force sample-tip feedback. The experimental setup for measuring the amplitude is easily integrated in an inverted microscope setup on which the shear force microscope is installed for simultaneous scanning probe and optical microscopy analysis of the sample.

  5. FORCES AND MOMENTS OF THE LIQUID FINITE AMPLITUDE SLOSHING IN A LIQUID-SOLID COUPLED SYSTEM

    Institute of Scientific and Technical Information of China (English)

    苟兴宇; 李铁寿; 马兴瑞; 王本利

    2001-01-01

    Nonlinear coupling dynamics between a spring-mass system and a finite amplitude sloshing system with liquid in a cylindrical tank is investigated. Based on a group of nonlinear coupling equations of six degrees of freedoms, analytical formulae of forces and moments of the liquid large amplitude sloshing were obtained. Nonlinearity of the forces and moments of the sloshing was induced by integrating on final configuration of liquid sloshing and the nonlinear terms in the liquid pressure formula. The symmetry between the formula of Ox and Oy direction proves that the derivation is correct. According to the coupled mechanism, the formulae are available in other liquid-solid coupled systems.Simulations and corresponding experimental results arecompared. It is shown that the forces and moments formulae by integrating on the final sloshing configuration are more reasonable. The omitted high-dimensional modal bases and high-order nonlinear terms and the complexity of sloshing damping are main sources of errors.

  6. Drive-amplitude-modulation atomic force microscopy: From vacuum to liquids

    Directory of Open Access Journals (Sweden)

    Miriam Jaafar

    2012-04-01

    Full Text Available We introduce drive-amplitude-modulation atomic force microscopy as a dynamic mode with outstanding performance in all environments from vacuum to liquids. As with frequency modulation, the new mode follows a feedback scheme with two nested loops: The first keeps the cantilever oscillation amplitude constant by regulating the driving force, and the second uses the driving force as the feedback variable for topography. Additionally, a phase-locked loop can be used as a parallel feedback allowing separation of the conservative and nonconservative interactions. We describe the basis of this mode and present some examples of its performance in three different environments. Drive-amplutide modulation is a very stable, intuitive and easy to use mode that is free of the feedback instability associated with the noncontact-to-contact transition that occurs in the frequency-modulation mode.

  7. Re-evaluation of the amplitude-force relationship of trunk muscles.

    Science.gov (United States)

    Huebner, Agnes; Faenger, Bernd; Scholle, Hans-Christoph; Anders, Christoph

    2015-04-13

    Amplitude-force relationships of major trunk muscles are established in terms of curve characteristics, but up to now were not normalized with respect to maximum voluntary contraction (MVC) force levels. The study therefore aims at a re-evaluation of trunk muscle amplitude-force relationship data according to MVC. Surface EMG of five major trunk muscles was taken from 50 healthy subjects of both sexes (age 20-40 years). All tasks were performed in a device where submaximal loads on the trunk were applied by gradually tilting the subjects in sagittal plane to horizontal position. MVC flexion and extension forces were determined in upright position using an additional harness over the subject's shoulders. Furthermore, the subject's upper body mass (UBM) was obtained during forward tilt to horizontal. MVC to UBM ratio was calculated, corrected by the actual tilt angle, and these linearly estimated values compared with the measured relative values according to MVC. All abdominal muscles confirmed the known non-linear amplitude-force relationship. At low load levels the linearly estimated values overestimated the measured ones and, at higher load levels, underestimated the true stress levels considerably. Back muscles confirmed the known linear curve shape, but for the longissimus muscle at L1 level measured data was always below estimated values. With increasing load, muscular stress of abdominal muscles changes from overestimated towards considerably underestimated values if expected stress levels are based on linear interpolation. Major back muscles' activation levels are nearly linear, but the amplitude-force relationship values seem overestimated for longissimus.

  8. Shortening amplitude affects the incomplete force recovery after active shortening in mouse soleus muscle.

    Science.gov (United States)

    Van Noten, Pieter; Van Leemputte, Marc

    2009-12-11

    Compared to isometric contraction, the force producing capacity of muscle is reduced (force depression, FD) after a work producing shortening phase. It has been suggested that FD results from an inhibition of cross-bridge binding. Because the rate constants of the exponential force (re)development are thought to be primarily determined by cross-bridge attachment/detachment rate, we aimed to investigate the components of force redevelopment (REDEV) after 0.6, 1.2 and 2.4mm shortening, resulting in varying amounts of FD (from about 5% to about 16%), in mouse soleus muscle (n=11). Compared to isometric force development (DEV), the time to reach steady-state during REDEV was about 3 times longer (370 versus 1261ms) increasing with increasing amplitude. Contrary to a single, a double exponential function with one component set equal to the rate constant of DEV (14.3s(-1)), accurately described REDEV (RMSshortening amplitude and was associated with work delivered during shortening (R(2)=0.75) and FD (R(2)=0.77). We concluded that a work related slow exponential component is induced to the trajectory of incomplete force recovery after shortening, causing FD. These results suggest that after shortening, aside from cross-bridges with normal attachment/detachment rate, cross-bridges with reduced cycling rate are active.

  9. Tip radius preservation for high resolution imaging in amplitude modulation atomic force microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Jorge R., E-mail: jorge.rr@cea.cu [Instituto de Ciencia de Materiales de Madrid, Sor Juana Inés de la Cruz 3, Canto Blanco, 28049 Madrid, España (Spain)

    2014-07-28

    The acquisition of high resolution images in atomic force microscopy (AFM) is correlated to the cantilever's tip shape, size, and imaging conditions. In this work, relative tip wear is quantified based on the evolution of a direct experimental observable in amplitude modulation atomic force microscopy, i.e., the critical amplitude. We further show that the scanning parameters required to guarantee a maximum compressive stress that is lower than the yield/fracture stress of the tip can be estimated via experimental observables. In both counts, the optimized parameters to acquire AFM images while preserving the tip are discussed. The results are validated experimentally by employing IgG antibodies as a model system.

  10. Unsteady aerodynamic force mechanisms of a hoverfly hovering with a short stroke-amplitude

    Science.gov (United States)

    Zhu, Hao Jie; Sun, Mao

    2017-08-01

    Hovering insects require a rather large lift coefficient. Many insects hover with a large stroke amplitude (120°-170°), and it has been found that the high lift is mainly produced by the delayed-stall mechanism. However, some insects hover with a small stroke amplitude (e.g., 65°). The delayed-stall mechanism might not work for these insects because the wings travel only a very short distance in a stroke, and other aerodynamic mechanisms must be operating. Here we explore the aerodynamic mechanisms of a hoverfly hovering with an inclined stroke plane and a small stroke amplitude (65.6°). The Navier-Stokes equations are numerically solved to give the flows and forces and the theory of vorticity dynamics used to reveal the aerodynamic mechanisms. The majority of the weight-supporting vertical force is produced in the mid portion of the downstroke, a short period (about 26% of the stroke cycle) in which the vertical force coefficient is larger than 4. The force is produced using a new mechanism, the "paddling mechanism." During the short period, the wing moves rapidly downward and forward at a large angle of attack (about 48°), and strong counter clockwise vorticity is produced continuously at the trailing edge and clockwise vorticity at the leading edge, resulting in a large time rate of change in the first moment of vorticity, hence the large aerodynamic force. It is interesting to note that with the well known delayed stall mechanism, the force is produced by the relative motion of two vortices of opposite sign, while in the "paddling mechanism," it is produced by generating new vortices of opposite sign at different locations.

  11. Standard practice for verification of constant amplitude dynamic forces in an axial fatigue testing system

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This practice covers procedures for the dynamic verification of cyclic force amplitude control or measurement accuracy during constant amplitude testing in an axial fatigue testing system. It is based on the premise that force verification can be done with the use of a strain gaged elastic element. Use of this practice gives assurance that the accuracies of forces applied by the machine or dynamic force readings from the test machine, at the time of the test, after any user applied correction factors, fall within the limits recommended in Section 9. It does not address static accuracy which must first be addressed using Practices E 4 or equivalent. 1.2 Verification is specific to a particular test machine configuration and specimen. This standard is recommended to be used for each configuration of testing machine and specimen. Where dynamic correction factors are to be applied to test machine force readings in order to meet the accuracy recommended in Section 9, the verification is also specific to the c...

  12. Determination of electrostatic force and its characteristics based on phase difference by amplitude modulation atomic force microscopy

    Science.gov (United States)

    Wang, Kesheng; Cheng, Jia; Yao, Shiji; Lu, Yijia; Ji, Linhong; Xu, Dengfeng

    2016-12-01

    Electrostatic force measurement at the micro/nano scale is of great significance in science and engineering. In this paper, a reasonable way of applying voltage is put forward by taking an electrostatic chuck in a real integrated circuit manufacturing process as a sample, applying voltage in the probe and the sample electrode, respectively, and comparing the measurement effect of the probe oscillation phase difference by amplitude modulation atomic force microscopy. Based on the phase difference obtained from the experiment, the quantitative dependence of the absolute magnitude of the electrostatic force on the tip-sample distance and applied voltage is established by means of theoretical analysis and numerical simulation. The results show that the varying characteristics of the electrostatic force with the distance and voltage at the micro/nano scale are similar to those at the macroscopic scale. Electrostatic force gradually decays with increasing distance. Electrostatic force is basically proportional to the square of applied voltage. Meanwhile, the applicable conditions of the above laws are discussed. In addition, a comparison of the results in this paper with the results of the energy dissipation method shows the two are consistent in general. The error decreases with increasing distance, and the effect of voltage on the error is small.

  13. Subharmonic excitation in amplitude modulation atomic force microscopy in the presence of adsorbed water layers

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Sergio [Laboratory of Energy and Nanosciences, Masdar Institute of Science and Technology, P.O. BOX 54224, Abu Dhabi (United Arab Emirates); Barcons, Victor [Departament de Disseny i Programacio de Sistemes Electronics, UPC - Universitat Politecnica de Catalunya Av. Bases, 61, 08242 Manresa (Spain); Verdaguer, Albert [Centre d' Investigacio en Nanociencia i Nanotecnologia (CIN2) (CSIC-ICN), Esfera UAB, Campus de la UAB, Edifici CM-7, 08193-Bellaterra, Catalunya (Spain); Chiesa, Matteo [Laboratory of Energy and Nanosciences, Masdar Institute of Science and Technology, P.O. BOX 54224, Abu Dhabi (United Arab Emirates); Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139-4307 (United States)

    2011-12-01

    In ambient conditions, nanometric water layers form on hydrophilic surfaces covering them and significantly changing their properties and characteristics. Here we report the excitation of subharmonics in amplitude modulation atomic force microscopy induced by intermittent water contacts. Our simulations show that there are several regimes of operation depending on whether there is perturbation of water layers. Single period orbitals, where subharmonics are never induced, follow only when the tip is either in permanent contact with the water layers or in pure noncontact where the water layers are never perturbed. When the water layers are perturbed subharmonic excitation increases with decreasing oscillation amplitude. We derive an analytical expression which establishes whether water perturbations compromise harmonic motion and show that the predictions are in agreement with numerical simulations. Empirical validation of our interpretation is provided by the observation of a range of values for apparent height of water layers when subharmonic excitation is predicted.

  14. Variability of grip kinetics during adult signature writing.

    Directory of Open Access Journals (Sweden)

    Bassma Ghali

    Full Text Available Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20 adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of 1.2±0.4% in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively.

  15. Variability of grip kinetics during adult signature writing.

    Science.gov (United States)

    Ghali, Bassma; Thalanki Anantha, Nayanashri; Chan, Jennifer; Chau, Tom

    2013-01-01

    Grip kinetics and their variation are emerging as important considerations in the clinical assessment of handwriting pathologies, fine motor rehabilitation, biometrics, forensics and ergonomic pen design. This study evaluated the intra- and inter-participant variability of grip shape kinetics in adults during signature writing. Twenty (20) adult participants wrote on a digitizing tablet using an instrumented pen that measured the forces exerted on its barrel. Signature samples were collected over 10 days, 3 times a day, to capture temporal variations in grip shape kinetics. A kinetic topography (i.e., grip shape image) was derived per signature by time-averaging the measured force at each of 32 locations around the pen barrel. The normalized cross correlations (NCC) of grip shape images were calculated within- and between-participants. Several classification algorithms were implemented to gauge the error rate of participant discrimination based on grip shape kinetics. Four different grip shapes emerged and several participants made grip adjustments (change in grip shape or grip height) or rotated the pen during writing. Nonetheless, intra-participant variation in grip kinetics was generally much smaller than inter-participant force variations. Using the entire grip shape images as a 32-dimensional input feature vector, a K-nearest neighbor classifier achieved an error rate of 1.2±0.4% in discriminating among participants. These results indicate that writers had unique grip shape kinetics that were repeatable over time but distinct from those of other participants. The topographic analysis of grip kinetics may inform the development of personalized interventions or customizable grips in clinical and industrial applications, respectively.

  16. Metabolic pathways reconstruction by frequency and amplitude response to forced glycolytic oscillations in yeast.

    Science.gov (United States)

    Zimmerman, William B

    2005-10-05

    The hypothesis that frequency and amplitude response can be used in a complicated metabolic pathway kinetics model for optimal parameter estimation, as speculated by its successful prior usage for a mechanical oscillator and a heterogeneous chemical system, is tested here. Given the complexity of the glycolysis model of yeast chosen, this question is limited to three kinetics parameters of the 87 in the in vitro model developed in the literature. The direct application of the approach, used with the uninformed selection of operating conditions for the oscillation of external glucose concentration, led to miring the data assimilation process in local minima. Application of linear systems theory, however, identified two natural resonant frequencies that, when excited by external forced oscillations of the same frequency, result in the expression of many harmonics in the Fourier spectra, that is, information-rich experiments. A single such information-rich experiment at one of the resonant frequencies was sufficient to break away from the local minima to find the optimum kinetics parameter estimates. The resonant frequencies themselves represent oscillation modes in glycolysis akin to those previously observed. Furthermore, operation of the bioreactor with large amplitude oscillations of glucose feed (25%) leads to enhanced ethanol average yield by 1.6% at the resonant frequency.

  17. Hand-grip isometric strength in judo

    Directory of Open Access Journals (Sweden)

    Juan G Bonitch-Góngora

    2014-02-01

    Full Text Available The grip is an important technical and tactical aspect through which the judokas dominate the adversary, hindering the application of appropriate techniques and favoring their own attack. The judokas must have high levels of isometric force and endurance to this type of force on the gripping muscles of the forearms, as one of the key aspects for success. This article reviews the grip muscular strength and endurance profiles of judokas of different groups (gender, age and competitive level. In general, the peak isometric strength of elite judokas has not changed in the last 40 years and is similar to that reached by non-elite judokas or even registered in large populations. This indicate that the evaluation of the isometric hand grip endurance may be a more relevant parameter than the peak isometric force in judokas, as during the bouts the grip must be maintained for relatively long periods of time and the maximum force cannot be maintained for long. However there are few studies on the ability to resist successive isometric handgrip stress in judokas.

  18. Forearm posture and grip effects during push and pull tasks.

    Science.gov (United States)

    Di Domizio, Jennifer; Keir, Peter J

    2010-03-01

    Direction of loading and performance of multiple tasks have been shown to elevate muscle activity in the upper extremity. The purpose of this study was to evaluate the effects of gripping on muscle activity and applied force during pushing and pulling tasks with three forearm postures. Twelve volunteers performed five hand-based tasks in supinated, neutral and pronated forearm postures with the elbow at 90 degrees and upper arm vertical. All tasks were performed with the right (dominant) hand and included hand grip alone, push and pull with and without hand grip. Surface EMG from eight upper extremity muscles, hand grip force, tri-axial push and pull forces and wrist angles were recorded during the 10 s trials. The addition of a pull force to hand grip elevated activity in all forearm muscles (all p push with grip tasks, forearm extensor muscle activity tended to increase when compared with grip only while flexor activity tended to decrease. Forearm extensor muscle activity was higher with the forearm pronated compared with neutral and supinated postures during most isolated grip tasks and push or pull with grip tasks (all p push and pull forces could act to assist in creating grip force, forearm muscle activity generally decreased. These results provide strategies for reducing forearm muscle loading in the workplace. STATEMENT OF RELEVANCE: Tools and tasks designed to take advantage of coupling grip with push or pull actions may be beneficial in reducing stress and injury in the muscles of the forearm. These factors should be considered in assessing the workplace in terms of acute and cumulative loading.

  19. Cantilever tilt causing amplitude related convolution in dynamic mode atomic force microscopy.

    Science.gov (United States)

    Wang, Chunmei; Sun, Jielin; Itoh, Hiroshi; Shen, Dianhong; Hu, Jun

    2011-01-01

    It is well known that the topography in atomic force microscopy (AFM) is a convolution of the tip's shape and the sample's geometry. The classical convolution model was established in contact mode assuming a static probe, but it is no longer valid in dynamic mode AFM. It is still not well understood whether or how the vibration of the probe in dynamic mode affects the convolution. Such ignorance complicates the interpretation of the topography. Here we propose a convolution model for dynamic mode by taking into account the typical design of the cantilever tilt in AFMs, which leads to a different convolution from that in contact mode. Our model indicates that the cantilever tilt results in a dynamic convolution affected by the absolute value of the amplitude, especially in the case that corresponding contact convolution has sharp edges beyond certain angle. The effect was experimentally demonstrated by a perpendicular SiO(2)/Si super-lattice structure. Our model is useful for quantitative characterizations in dynamic mode, especially in probe characterization and critical dimension measurements.

  20. Practical loss tangent imaging with amplitude-modulated atomic force microscopy

    Science.gov (United States)

    Proksch, Roger; Kocun, Marta; Hurley, Donna; Viani, Mario; Labuda, Aleks; Meinhold, Waiman; Bemis, Jason

    2016-04-01

    Amplitude-modulated (AM) atomic force microscopy (AFM), also known as tapping or AC mode, is a proven, reliable, and gentle imaging method with widespread applications. Previously, the contrast in AM-AFM has been difficult to quantify. AFM loss tangent imaging is a recently introduced technique that recasts AM mode phase imaging into a single term tan δ that includes both the dissipated and stored energy of the tip-sample interaction. It promises fast, versatile mapping of variations in near-surface viscoelastic properties. However, experiments to date have generally obtained values larger than expected for the viscoelastic loss tangent of materials. Here, we explore and discuss several practical considerations for AFM loss tangent imaging experiments. A frequent limitation to tapping in air is Brownian (thermal) motion of the cantilever. This fundamental noise source limits the accuracy of loss tangent estimation to approximately 0.01 phase transitions, even in the presence of such non-ideal interactions. These results help understand the limits and opportunities not only of this particular technique but also of AM mode with phase imaging in general.

  1. An Efficient Approach for Determining Forced Vibration Response Amplitudes of a MDOF System with Various Attachments

    Directory of Open Access Journals (Sweden)

    J.S. Wu

    2012-01-01

    of the same vibrating system are calculated by using a relationship between |Y(x|t and |Y(x|s obtained from the single-degree-of-freedom (SDOF vibrating system. It is noted that, near resonance (i.e., we/w≈ 1.0, the entire MDOF system (with natural frequency w will vibrate synchronously in a certain mode and can be modeled by a SDOF system. Finally, the conventional finite element method (FEM incorporated with the Newmark's direct integration method is also used to determine the "total" response amplitudes |Y(x|t of the same forced vibrating system from the time histories of dynamic responses at each specified exciting frequency we. It has been found that the numerical results of the presented approach are in good agreement with those of FEM, this confirms the reliability of the presented theory. Because the CPU time required by the presented approach is less than 1% of that required by the conventional FEM, the presented approach should be an efficient technique for the title problem.

  2. Enhanced sensitivity and contrast with bimodal atomic force microscopy with small and ultra-small amplitudes in ambient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Sergio [Departament de Disseny i Programació de Sistemes Electrònics, UPC-Universitat Politècnica de Catalunya Av. Bases, 61, 08242 Manresa (Barcelona) (Spain)

    2013-12-02

    Here, we introduce bimodal atomic force microscopy operated with sub-nm and ultra-small, i.e., sub-angstrom, first and second mode amplitudes in ambient conditions. We show how the tip can be made to oscillate in the proximity of the surface and in perpetual contact with the adsorbed water layers while the second mode amplitude and phase provide enhanced contrast and sensitivity. Nonlinear and nonmonotonic behavior of the experimental observables is discussed theoretically with a view to high resolution, enhanced contrast, and minimally invasive mapping. Fractions of meV of energy dissipation are shown to provide contrast above the noise level.

  3. Change of amplitude of motion and force of hand for women after a radical mammectomy

    OpenAIRE

    Odinec T.E.

    2009-01-01

    The estimation of dynamometer of brush and amplitude of motion is rotined in a humeral joint for women. The features of remote postprocess period are considered after a radical mammectomy. Close correlation is rotined between amplitude of motion and index of function of the external breathing. The results of goniometer and dynamometer are presented. A hydrokinesitherapy is considered from position of perspective mean of rehabilitation of the functional state of women. The high degree of inter...

  4. [Grip strength changes in familial amyloidotic polyneuropathy].

    Science.gov (United States)

    Tomás, Maria Teresa; Santa-Clara, Helena; Monteiro, Estela; Carolino, Elizabete; Freire, António; Barroso, Eduardo

    2010-01-01

    Familial amiloidotic polyneuropathy (FAP) is an autossomical and dominant neurodegenerative disease related with systemic deposition of amyloid fibre mainly on peripheral nervous system. Clinically, is translated by an autonomous sensitive-motor polyneuropathy with beginning nearly always in foot, involving subsequently the hands. Until now, the unique available treatment for FAP disease is liver transplantation requiring medication that negatively affect muscle metabolism and force production mechanism. To our knowledge there are no quantitative characterizations of peak force in FAP patients or any comparison with healthy people. This knowledge will be extremely important to verify clinical and functional evolution of this disease and eventually prescribe an effective rehabilitation program. The purpose of this study was to analyse and compare levels of hand grip strength (peak force and endurance) in FAP patients with (FAPTx) or without (FAPNTx) a liver transplant with a group of healthy people (GC). The total sample of individuals where two hundred and six, assigned in 3 groups: 59 patients PAFNTx (23 males, 36 female; age 35 ± 8 years); 90 patients PAFTx (53 males, 37 females; age 34 ± 8 years) e 62 healthy persons (GC) (30 males, 32 females; age 33 ± 9 years). Grip strength was assessed by a portable grip dynamometer E-link (Biometrics Ltd, UK). All measurements were taken on standardized positions with standardized orders. The value noted to peak force was classified according to American College of Sports Medicine norms for grip strength. The 3 groups are differents (p < 0,05) for weigth, body mass index (BMI) and grip strength in both hands and endurance for left hand. Negative correlations between age and grip strength were found for PAFNTx and PAFTx but not for GC. According to our results FAP patients have lower values for grip strength in both hands than healthy subjects and consequently a worse classification in ACSM norms. Most patients present

  5. Hand grip strength

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Gaist, David; Petersen, Hans Christian

    2002-01-01

    in life is a major problem in terms of prevalence, morbidity, functional limitations, and quality of life. It is therefore of interest to find a phenotype reflecting physical functioning which has a relatively high heritability and which can be measured in large samples. Hand grip strength is known......-55%). A powerful design to detect genes associated with a phenotype is obtained using the extreme discordant and concordant sib pairs, of whom 28 and 77 dizygotic twin pairs, respectively, were found in this study. Hence grip strength is a suitable phenotype for identifying genetic variants of importance to mid...

  6. Gripping tool for the ITER upper port plug RH extraction/insertion

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, Elena V., E-mail: elena.rosa@ciemat.es; Ríos, Luis, E-mail: luis.rios@ciemat.es

    2014-10-15

    Highlights: •The gripping tool is based on only one gripping point centred at the plug bottom. •The gripping tool should allow the relative displacement in the gripping point to absorb the misalignment between plug and tractor. •The gripping tool needs to withstand around 100/30 kN during the plug extraction/insertion. •The gripping tool should rely on visual control and it has to avoid force feed-back. •The comparison between the features of several gripping tool concepts is assessed. -- Abstract: The conceptual design of several gripping tools and their mechanical interfaces is being carried out for the ITER ECH UPP within the WP10-GOTRH programme. EFDA finances the GOT RH (Goal Oriented Training Programme for Remote Handling). The purpose of this paper is to introduce new concepts of gripping tools for the plug extraction/insertion in the upper port of ITER. All these gripping tools are designed according to IO input data and geometrical constraints. The gripping tools have to be able to extract/insert the plug in the scenario of maximum misalignment between the plug and the tractor. The paper also defines the functional requirements the gripping tools need to comply with. The requirements and input data are verified and validated through 3D simulation with Catia mock-ups of the gripping tools. The strengths and weaknesses of each gripping tool model are compared.

  7. Change of amplitude of motion and force of hand for women after a radical mammectomy

    Directory of Open Access Journals (Sweden)

    Odinec T.E.

    2009-12-01

    Full Text Available The estimation of dynamometer of brush and amplitude of motion is rotined in a humeral joint for women. The features of remote postprocess period are considered after a radical mammectomy. Close correlation is rotined between amplitude of motion and index of function of the external breathing. The results of goniometer and dynamometer are presented. A hydrokinesitherapy is considered from position of perspective mean of rehabilitation of the functional state of women. The high degree of intercommunication is rotined between taking and bending in a humeral joint the vital capacity of lights.

  8. Individual finger contribution in submaximal voluntary contraction of gripping.

    Science.gov (United States)

    Kong, Yong-Ku; Lee, Kyung-Sun; Kim, Dae-Min; Jung, Myung-Chul

    2011-11-01

    The objective of this study was to evaluate individual finger force and contribution to a gripping force, the difference between actual and expected finger forces and subjective discomfort rating at 10 different submaximal voluntary contraction (%MVC) levels (10-100% in 10 increments). Seventy-two participants randomly exerted gripping force with a multi-finger force measurement system. The individual finger force, gripping force and discomfort increased as %MVC levels increased. The middle and ring fingers exerted more force and contributed to a gripping force more than the index and little fingers due to their larger mass fractions of the digit flexor muscles. It was apparent at MVC; however, the index finger increased its contribution and exerted even more force than expected at more than 50% MVC. Subjective discomfort supported the results of the objective measures. This could explain the conflicting findings between index and ring fingers in previous finger contribution studies. STATEMENT OF RELEVANCE: Hand tool design is of special interest in ergonomics due to its association with musculoskeletal disorders in the hand. This study reveals a different contribution pattern of the fingers in submaximal voluntary contraction of gripping exertion.

  9. Pulsed laser manipulation of an optically trapped bead: Averaging thermal noise and measuring the pulsed force amplitude

    DEFF Research Database (Denmark)

    Lindballe, Thue Bjerring; Kristensen, Martin V. G.; Berg-Sørensen, Kirstine

    2013-01-01

    An experimental strategy for post-eliminating thermal noise on position measurements of optically trapped particles is presented. Using a nanosecond pulsed laser, synchronized to the detection system, to exert a periodic driving force on an optically trapped 10 polystyrene bead, the laser pulse......-bead interaction is repeated hundreds of times. Traces with the bead position following the prompt displacement from equilibrium, induced by each laser pulse, are averaged and reveal the underlying deterministic motion of the bead, which is not visible in a single trace due to thermal noise. The motion of the bead...... is analyzed from the direct time-dependent position measurements and from the power spectrum. The results show that the bead is on average displaced 208 nm from the trap center and exposed to a force amplitude of 71 nanoNewton, more than five orders of magnitude larger than the trapping forces. Our...

  10. Vibrational analysis of single-layered piezoelectric AFM microcantilever in amplitude mode by considering the capillary force

    Science.gov (United States)

    Habibnejad Korayem, Alireza; Habibnejad Korayem, Moharam; Ghaderi, Reza

    2014-12-01

    In this article, the vibrational behavior of a microcantilever (MC) with an extended piezoelectric layer in the air ambient undergoes examination. To model the vibrational motion of this type of cantilever, the Hamilton's principle has been used. For this purpose, the MC vibrational equation has been derived by the assumption of the continuous beam based on the Euler-Bernoulli beam theory. By adopting the finite element method (FEM), the MC differential equation has been solved. In the present simulation not only van der Waals and contact forces but also the capillary forces resulting from the condensation of the water vapors in air on MC tip have been considered. The results illustrate that the force between the sample surface and the probe affects the MC amplitude; furthermore, it causes the reduction in the resonance frequency. In addition, to reduce the time delay during topography from the surface roughness, it is better to select MCs with larger width and length and smaller thickness. Furthermore, the results indicate that the best imaging takes place when the vibration is in its second vibrational mode. Finally, the effects of MC geometric parameters on the time delay between the starting moment of surface roughness and the moment of variation in the MC amplitude (surface roughness topography) have been analyzed.

  11. A complete set of total cross sections for imaginary parts of nd forward scattering amplitudes and three-nucleon force effects

    CERN Document Server

    Ishikawa, S; Iseri, Y

    2001-01-01

    In the neutron-deuteron scattering, four total cross sections are shown to form a complete set for the determination of the imaginary parts of the forward amplitudes because of the optical theorem. The amplitudes are decomposed into scalar and tensor ones in the spin space. Contributions of three-nucleon forces (3NF) to these amplitudes are studied, by the Faddeev calculation, which predicts significant tensor effects of the 3NF.

  12. Enter the Gripping Beast

    DEFF Research Database (Denmark)

    Sindbæk, Søren Michael

    2012-01-01

    of communities and their life world. Transcending technology, cultural dispositions and social relations, the study of innovations invites an actor-networks approach, which considers the heterogeneous nature of human-material relations. The archaeological record is potentially a rich source of evidence...... on innovations. Mostly, however, the time-resolution of archaeological data is too coarse-grained to allow us to grasp this potential to the full. In the period c. AD 790-850 a distinctly new artistic motif, the Gripping Beast, emerged in Scandinavia. A series of narrowly dated contexts provide anchor points...

  13. Fuzzy logic based grip force control method for myoelectric prosthesis with tactile feedback%带触觉的肌电假手握力模糊控制方法

    Institute of Scientific and Technical Information of China (English)

    章华涛; 吴常铖; 郭晏; 包加桐; 宋爱国

    2013-01-01

    In light of the feeling and experience of the disabled,this paper proposes a new grip force control method for myoelectric prosthesis.According to the theory of STFT,the whole myoelectric signal is divided into several time segments.Some representative parameters of the surface electromyography (SEMG) signal in these time segments are selected,which are analyzed and processed with a trained neural network,and then the muscle force strength is estimated.The tactile information obtained from the tactile sensor at the prosthesis finger end and the muscle force strength signal are inputted into the fuzzy logic controller,then the motor speed of the myoelectric prosthesis is adjusted according to the designed fuzzy logic rules so that the grip force can be adjusted.This method could significantly minimize the influences of individual difference of the SEMG signal and the detection position of the SEMG sensors on the control effects,and decrease the installation difficulty of the myoelectric sensor,which can be used by non-specific disabled.Experiment results prove the effectiveness of the proposed grip force control method.%从注重残疾人本体感出发,提出了一种新的用于肌电假手握力控制的方法.该方法利用短时傅里叶变换思想对信号进行时间片分割,并对时间片内的信号分析选取了几个具有代表性的肌电信号参数,并用训练后的神经网络对其进行分析处理,进而估计出相应的肌肉用力大小.同时将肌电假手指端的力触觉传感器所得的力触觉信号和肌肉用力大小信号输入模糊控制器,根据设计好的模糊控制规则调节肌电假手驱动电机的转动速度从而控制握力大小.该方法可以有效减小个人差异性和肌电信号传感器检测位置不同对控制效果的影响,可以减小肌电传感器安装难度并可供不同的残疾人使用.实验结果证明了该握力控制方法的有效性.

  14. Effects of carpal tunnel syndrome on dexterous manipulation are grip type-dependent.

    Science.gov (United States)

    Zhang, Wei; Johnston, Jamie A; Ross, Mark A; Sanniec, Kyle; Gleason, Elizabeth A; Dueck, Amylou C; Santello, Marco

    2013-01-01

    Carpal tunnel syndrome (CTS) impairs sensation of a subset of digits. Although the effects of CTS on manipulation performed with CTS-affected digits have been studied using precision grip tasks, the extent to which CTS affects multi-digit force coordination has only recently been studied. Whole-hand manipulation studies have shown that CTS patients retain the ability to modulate multi-digit forces to object mass, mass distribution, and texture. However, CTS results in sensorimotor deficits relative to healthy controls, including significantly larger grip force and lower ability to balance the torques generated by the digits. Here we investigated the effects of CTS on multi-digit force modulation to object weight when manipulating an object with a variable number of fingers. We hypothesized that CTS patients would be able to modulate digit forces to object weight. However, as different grip types involve the exclusive use of CTS-affected digits ('uniform' grips) or a combination of CTS-affected and non-affected digits ('mixed' grips), we addressed the question of whether 'mixed' grips would reduce or worsen CTS-induced force coordination deficits. The former scenario would be due to adding digits with intact tactile feedback, whereas the latter scenario might occur due to a potentially greater challenge for the central nervous system of integrating 'noisy' and intact tactile feedback. CTS patients learned multi-digit force modulation to object weight regardless of grip type. Although controls exerted the same total grip force across all grip types, patients exerted significantly larger grip force than controls but only for manipulations with four and five digits. Importantly, this effect was due to CTS patients' inability to change the finger force distribution when adding the ring and little fingers. These findings suggest that CTS primarily challenges sensorimotor integration processes for dexterous manipulation underlying the coordination of CTS-affected and non

  15. Effects of carpal tunnel syndrome on dexterous manipulation are grip type-dependent.

    Directory of Open Access Journals (Sweden)

    Wei Zhang

    Full Text Available Carpal tunnel syndrome (CTS impairs sensation of a subset of digits. Although the effects of CTS on manipulation performed with CTS-affected digits have been studied using precision grip tasks, the extent to which CTS affects multi-digit force coordination has only recently been studied. Whole-hand manipulation studies have shown that CTS patients retain the ability to modulate multi-digit forces to object mass, mass distribution, and texture. However, CTS results in sensorimotor deficits relative to healthy controls, including significantly larger grip force and lower ability to balance the torques generated by the digits. Here we investigated the effects of CTS on multi-digit force modulation to object weight when manipulating an object with a variable number of fingers. We hypothesized that CTS patients would be able to modulate digit forces to object weight. However, as different grip types involve the exclusive use of CTS-affected digits ('uniform' grips or a combination of CTS-affected and non-affected digits ('mixed' grips, we addressed the question of whether 'mixed' grips would reduce or worsen CTS-induced force coordination deficits. The former scenario would be due to adding digits with intact tactile feedback, whereas the latter scenario might occur due to a potentially greater challenge for the central nervous system of integrating 'noisy' and intact tactile feedback. CTS patients learned multi-digit force modulation to object weight regardless of grip type. Although controls exerted the same total grip force across all grip types, patients exerted significantly larger grip force than controls but only for manipulations with four and five digits. Importantly, this effect was due to CTS patients' inability to change the finger force distribution when adding the ring and little fingers. These findings suggest that CTS primarily challenges sensorimotor integration processes for dexterous manipulation underlying the coordination of CTS

  16. Kinetic measurements of hand motor impairments after mild to moderate stroke using grip control tasks.

    Science.gov (United States)

    Ye, Yu; Ma, Le; Yan, Tiebin; Liu, Huihua; Wei, Xijun; Song, Rong

    2014-05-11

    The aim of this study is to investigate quantitative outcome measurements of hand motor performance for subjects after mild to moderate stroke using grip control tasks and characterize abnormal flexion synergy of upper extremities after stroke. A customized dynamometer with force sensors was used to measure grip force and calculate rotation torque during the sub-maximal grip control tasks. The paretic and nonpartic sides of eleven subjects after stroke and the dominant sides of ten healthy persons were tested. Their maximal voluntary grip force was measured and used to set sub-maximal grip control tasks at three different target force levels. Force control ability was characterized by the maximal grip force, mean force percentage, coefficient of variation (CV), target deviation ratio (TDR), and rotation torque ratio (RTR). The motor impairments of subjects after stroke were also evaluated using the Fugl-Meyer assessment for upper extremity (FMA-UE) and Wolf Motor Function Test (WMFT). Maximal grip force of the paretic side was significantly reduced as compared to the nonparetic side and the healthy group, while the difference of maximal grip force between the nonparetic side and the healthy group was not significant. TDR and RTR increased for all three groups with increasing target force level. There were significant differences of CV, TDR and RTR between the paretic side and the healthy group at all the force levels. CV, TDR and RTR showed significant negative correlations with FMA-UE and WMFT at 50% of maximum grip force. This study designed a customized dynamometer together with an innovative measurement, RTR, to investigate the hand motor performance of subjects after mild to moderate stroke during force control tasks. And stroke-induced abnormal flexion synergy of wrist and finger muscles could be characterized by RTR. This study also identified a set of kinetic parameters which can be applied to quantitatively assess the hand motor function of subjects after

  17. Finding Relief from Allergy's Grip

    Science.gov (United States)

    ... Navigation Bar Home Current Issue Past Issues Finding Relief from Allergy's Grip Past Issues / Summer 2006 Table ... action for patients who have had inadequate symptom relief with antihistamines and topical nasal steroids. Through injection ...

  18. Mechanical Properties of Microcrystalline Metal-Organic Frameworks (MOFs) Measured by Bimodal Amplitude Modulated-Frequency Modulated Atomic Force Microscopy.

    Science.gov (United States)

    Sun, Yao; Hu, Zhigang; Zhao, Dan; Zeng, Kaiyang

    2017-09-08

    Direct measurement of the mechanical properties of microcrystalline metal-organic framework (MOF) nanoparticles is challenging and rarely explored. In this work, we apply an effective method to realize elastic modulus mapping of a series of isostructural single MOF nanoparticles (100-500 nm) via bimodal amplitude modulated-frequency modulated atomic force microscopy. By probing five types of zirconium (Zr) and hafnium (Hf) isostructural UiO-66-type MOFs, we experimentally found that UiO-66(Hf)-type MOFs possess the higher elastic modulus (46-104 GPa) than that of UiO-66(Zr)-type MOFs (34-100 GPa), both of which are higher than that of reported zinc/copper based MOFs (3-10 GPa). We also experimentally demonstrate that the mechanical properties of MOFs can be tuned by adjusting the chemical functionalities of the ligands or using different metal nodes. In detail, the sterically bulky functional groups increase the mechanical properties of the resultant UiO-66-type MOFs, possibly due to the increased atomic density. These results pave a way to the direct measurement of mechanical properties of MOFs crystalline particles and provide an incisive perspective to the design of MOFs with high mechanical properties.

  19. Biomimetics approach for methods to release microobjects from the gripping tool

    DEFF Research Database (Denmark)

    Gegeckaite, Asta; Moon, Jack; Hansen, Hans Nørgaard

    2005-01-01

    In the micro scale, gripping devices are working in the different way. New forces, working in the micro scale, like van der Waals, surface tension and electrostatics are influencing the gripping process. Handling of micro or even nano sized objects can be easily in the nature. Different types of ...

  20. Biomimetics approach for methods to release microobjects from the gripping tool

    DEFF Research Database (Denmark)

    Gegeckaite, Asta; Moon, Jack; Hansen, Hans Nørgaard

    2005-01-01

    In the micro scale, gripping devices are working in the different way. New forces, working in the micro scale, like van der Waals, surface tension and electrostatics are influencing the gripping process. Handling of micro or even nano sized objects can be easily in the nature. Different types of ...

  1. Gripping during climbing of arboreal snakes may be safe but not economical

    Science.gov (United States)

    Byrnes, Greg; Jayne, Bruce C.

    2014-01-01

    On the steep surfaces that are common in arboreal environments, many types of animals without claws or adhesive structures must use muscular force to generate sufficient normal force to prevent slipping and climb successfully. Unlike many limbed arboreal animals that have discrete gripping regions on the feet, the elongate bodies of snakes allow for considerable modulation of both the size and orientation of the gripping region. We quantified the gripping forces of snakes climbing a vertical cylinder to determine the extent to which their force production favoured economy or safety. Our sample included four boid species and one colubrid. Nearly all of the gripping forces that we observed for each snake exceeded our estimate of the minimum required, and snakes commonly produced more than three times the normal force required to support their body weight. This suggests that a large safety factor to avoid slipping and falling is more important than locomotor economy. PMID:25142200

  2. Grip pressure distributions and associated variability in golf: a two-club comparison.

    Science.gov (United States)

    Langlais, Sean M; Broker, Jeffrey P

    2014-06-01

    Teaching and playing professionals offer multiple theories concerning the manner in which forces should be applied to the handle of the club during the golf swing. This study extends recent research concerning grip pressures and forces in golf, with the purpose of exploring the similarities and differences between force profiles for a 7-iron and driver swung by proficient golfers. A secondary purpose was to further analyze the way that golfers use grip forces to manipulate the club. Grip forces were measured on eight low handicap golfers (USGA indexes 0 to 7) swinging their own 7-irons and drivers. In total, lead-hand and trail-hand grip forces were isolated as well as anatomically specific forces within the hands. Force profile variability across multiple swings for each golfer and between golfers characterized consistencies and important differences. Correlations between 7-iron and driver force profiles characterized force 'signatures.' The data highlight large fluctuations in grip forces during the swing. Marked differences between participants were observed, involving force magnitudes and phasing. Dominant forces arose primarily from the lead hand, specifically the last three fingers. Force profiles were highly repeatable across swings for a golfer (standard deviations high (r2 = 0.86). Notably, within swing force variability was greatest during club acceleration, but dramatically decreased at impact.

  3. Effect of wrist position on young adults pinch grip control

    Directory of Open Access Journals (Sweden)

    Vanessa Luzia Barros de Andrade

    2015-12-01

    Full Text Available Pinch grip is used in a large number of handling activities that require precision and control of an object. The position of the upper arm joints affects the fingers force production in order to handle the object. This study aimed to verify the influence of the wrist position in the production of maximum strength and in the control fingers grip pinch submaximum strength control. Participants were 21 right handed adults (10 male, 18-26 years old. They made two attempts of maximum force production and eight attempts of submaximal force production (four at 20% and four at 40% of maximum strength for pinch grip in three wrist positions: neutral, flexion and extension. The results showed that the production of maximum strength is higher in neutral position compared to wrist flexion and extension and higher for men compared to women. In addition, there was a positive correlation between the length of the hand and the production of maximum strength. The results also indicated that the wrist position did not interfere in the submaximum force control during this task. However, participants showed more difficulty controlling 20% than 40% of maximum strength. The present study showed evidence that the motor units used to produce grip pinch maximum strength cross the wrist joint but those used for the 20% and 40% of maximum strength are present only in the fingers and hand.

  4. Gripping System For Mechanical Testing Of Composites

    Science.gov (United States)

    Mackay, Rebecca A.; Nathal, Michael V.

    1994-01-01

    Specimens held without slippage, even at high temperatures. Improved gripping system designed to securely hold ends of specimen of composite material during creep or tensile test. Each grip includes pair of wedges having sharply corrugated gripping surfaces. Wedges held between two plates containing cavities sloped to accommodate wedges. Two such grips (one for each end) holds specimen in furnace connected to tensile test machine for creep measurements.

  5. Soft shape-adaptive gripping device made from artificial muscle

    Science.gov (United States)

    Hamburg, E.; Vunder, V.; Johanson, U.; Kaasik, F.; Aabloo, A.

    2016-04-01

    We report on a multifunctional four-finger gripper for soft robotics, suitable for performing delicate manipulation tasks. The gripping device is comprised of separately driven gripping and lifting mechanisms, both made from a separate single piece of smart material - ionic capacitive laminate (ICL) also known as artificial muscle. Compared to other similar devices the relatively high force output of the ICL material allows one to construct a device able to grab and lift objects exceeding multiple times its own weight. Due to flexible design of ICL grips, the device is able to adapt the complex shapes of different objects and allows grasping single or multiple objects simultaneously without damage. The performance of the gripper is evaluated in two different configurations: a) the ultimate grasping strength of the gripping hand; and b) the maximum lifting force of the lifting actuator. The ICL is composed of three main layers: a porous membrane consisting of non-ionic polymer poly(vinylidene fluoride-co-hexafluoropropene) (PVdF-HFP), ionic liquid 1-ethyl-3-methylimidazolium trifluoromethane-sulfonate (EMITFS), and a reinforcing layer of woven fiberglass cloth. Both sides of the membrane are coated with a carbonaceous electrode. The electrodes are additionally covered with thin gold layers, serving as current collectors. Device made of this material operates silently, requires low driving voltage (<3 V), and is suitable for performing tasks in open air environment.

  6. Effect of Sampling Rates on the Quantification of Forces, Durations, and Rates of Loading of Simulated Side Posture High-Velocity, Low-Amplitude Lumbar Spine Manipulation☆

    Science.gov (United States)

    Gudavalli, Maruti Ram; DeVocht, James; Tayh, Ali; Xia, Ting

    2013-01-01

    Objective Quantification of chiropractic high-velocity, low-amplitude spinal manipulation (HVLA-SM) may require biomechanical equipment capable of sampling data at high rates. However, there are few studies reported in the literature regarding the minimal sampling rate required to record the HVLA-SM force-time profile data accurately and precisely. The purpose of this study was to investigate the effect of different sampling rates on the quantification of forces, durations, and rates of loading of simulated side posture lumbar spine HVLA-SM delivered by doctors of chiropractic. Methods Five doctors of chiropractic (DCs) and 5 asymptomatic participants were recruited for this study. Force-time profiles were recorded during (i) 52 simulated HVLA-SM thrusts to a force transducer placed on a force plate by 2 DCs and (ii) 12 lumbar side posture HVLA-SM on 5 participants by 3 DCs. Data sampling rate of the force plate remained the same at 1000 Hz, whereas the sampling rate of the force transducer varied at 50, 100, 200, and 500 Hz. The data were reduced using custom-written MATLAB (Mathworks, Inc, Natick, MA) and MathCad (version 15; Parametric Technologies, Natick, MA) programs and analyzed descriptively. Results The average differences in the computed durations and rates of loading are smaller than 5% between 50 and 1000 Hz sampling rates. The differences in the computed preloads and peak loads are smaller than 3%. Conclusions The small differences observed in the characteristics of force-time profiles of simulated manual HVLA-SM thrusts measured using various sampling rates suggest that a sampling rate as low as 50 to 100 Hz may be sufficient. The results are applicable to the manipulation performed in this study: manual side posture lumbar spine HVLA-SM. PMID:23790603

  7. Effect of sampling rates on the quantification of forces, durations, and rates of loading of simulated side posture high-velocity, low-amplitude lumbar spine manipulation.

    Science.gov (United States)

    Gudavalli, Maruti Ram; DeVocht, James; Tayh, Ali; Xia, Ting

    2013-06-01

    Quantification of chiropractic high-velocity, low-amplitude spinal manipulation (HVLA-SM) may require biomechanical equipment capable of sampling data at high rates. However, there are few studies reported in the literature regarding the minimal sampling rate required to record the HVLA-SM force-time profile data accurately and precisely. The purpose of this study was to investigate the effect of different sampling rates on the quantification of forces, durations, and rates of loading of simulated side posture lumbar spine HVLA-SM delivered by doctors of chiropractic. Five doctors of chiropractic (DCs) and 5 asymptomatic participants were recruited for this study. Force-time profiles were recorded during (i) 52 simulated HVLA-SM thrusts to a force transducer placed on a force plate by 2 DCs and (ii) 12 lumbar side posture HVLA-SM on 5 participants by 3 DCs. Data sampling rate of the force plate remained the same at 1000 Hz, whereas the sampling rate of the force transducer varied at 50, 100, 200, and 500 Hz. The data were reduced using custom-written MATLAB (Mathworks, Inc, Natick, MA) and MathCad (version 15; Parametric Technologies, Natick, MA) programs and analyzed descriptively. The average differences in the computed durations and rates of loading are smaller than 5% between 50 and 1000 Hz sampling rates. The differences in the computed preloads and peak loads are smaller than 3%. The small differences observed in the characteristics of force-time profiles of simulated manual HVLA-SM thrusts measured using various sampling rates suggest that a sampling rate as low as 50 to 100 Hz may be sufficient. The results are applicable to the manipulation performed in this study: manual side posture lumbar spine HVLA-SM. Copyright © 2013 The Authors. Published by Mosby, Inc. All rights reserved.

  8. Examinations of factors influencing toe grip strength.

    Science.gov (United States)

    Soma, Masayuki; Murata, Shin; Kai, Yoshihiro; Nakae, Hideyuki; Satou, Yousuke; Murata, Jun; Miyazaki, Junya

    2016-11-01

    [Purpose] This study examined the relationship between toe grip strength and its associated factors by focusing on factors that were suggested to have a relationship with toe grip strength in previous studies, aiming to clarify the factors influencing the toe grip strength of healthy women. [Subjects and Methods] Twelve healthy young women were selected for this study. Their toe grip strength, angular changes in their ankle joint during toe grip, maximum voluntary contraction activities of the rectus femoris, biceps femoris, and tibialis anterior muscles, and the medial head of the gastrocnemius muscles were measured using electromyography. Their toe curl ability, foot-arch height ratio, and weight were also measured. [Results] Multiple regression analysis demonstrated that the predictors of toe grip strength in the resulting model were foot-arch height ratio and the percentage of integrated electromyography (%IEMG) of the tibialis anterior muscle, as the dependent variables. This reveals that women whose tibialis anterior muscle %IEMG values and foot-arch height ratio are high have greater %IEMG values have greater toe grip strength. [Conclusion] These findings suggest a significant relationship between foot-arch height ratio and toe grip strength, with a reciprocal interaction. These findings further indicate that the risk of falls by the elderly could be decreased if toe grip strength were enhanced, by increasing the height of a low foot-arch with the help of an inserted insole.

  9. Dimensional comparison between amplitude-modulation atomic force microscopy and scanning ion conductance microscopy of biological samples

    Science.gov (United States)

    Kim, Joonhui; Choi, MyungHoon; Jung, Goo-Eun; Rahim Ferhan, Abdul; Cho, Nam-Joon; Cho, Sang-Joon

    2016-08-01

    The range of scanning probe microscopy (SPM) applications for atomic force microscopy (AFM) is expanding in the biological sciences field, reflecting an increasing demand for tools that can improve our fundamental understanding of the physics behind biological systems. However, the complexity associated with applying SPM techniques in biomedical research hampers the full exploitation of its capabilities. Recently, the development of scanning ion conductance microscopy (SICM) has overcome these limitations and enabled contact-free, high resolution imaging of live biological specimens. In this work, we demonstrate the limitation of AFM for imaging biological samples in liquid due to artifacts arising from AFM tip-sample interaction, and how SICM imaging is able to overcome those limitations with contact-free scanning. We also demonstrate that SICM measurements, when compared to AFM, show better fit to the actual dimensions of the biological samples. Our results highlight the superiority of SICM imaging, enabling it to be widely adopted as a general and versatile research tool for biological studies in the nanoscale.

  10. Relationship between Biomechanical Characteristics of Spinal Manipulation and Neural Responses in an Animal Model: Effect of Linear Control of Thrust Displacement versus Force, Thrust Amplitude, Thrust Duration, and Thrust Rate

    Directory of Open Access Journals (Sweden)

    William R. Reed

    2013-01-01

    Full Text Available High velocity low amplitude spinal manipulation (HVLA-SM is used frequently to treat musculoskeletal complaints. Little is known about the intervention’s biomechanical characteristics that determine its clinical benefit. Using an animal preparation, we determined how neural activity from lumbar muscle spindles during a lumbar HVLA-SM is affected by the type of thrust control and by the thrust's amplitude, duration, and rate. A mechanical device was used to apply a linear increase in thrust displacement or force and to control thrust duration. Under displacement control, neural responses during the HVLA-SM increased in a fashion graded with thrust amplitude. Under force control neural responses were similar regardless of the thrust amplitude. Decreasing thrust durations at all thrust amplitudes except the smallest thrust displacement had an overall significant effect on increasing muscle spindle activity during the HVLA-SMs. Under force control, spindle responses specifically and significantly increased between thrust durations of 75 and 150 ms suggesting the presence of a threshold value. Thrust velocities greater than 20–30 mm/s and thrust rates greater than 300 N/s tended to maximize the spindle responses. This study provides a basis for considering biomechanical characteristics of an HVLA-SM that should be measured and reported in clinical efficacy studies to help define effective clinical dosages.

  11. Relationship between Biomechanical Characteristics of Spinal Manipulation and Neural Responses in an Animal Model: Effect of Linear Control of Thrust Displacement versus Force, Thrust Amplitude, Thrust Duration, and Thrust Rate.

    Science.gov (United States)

    Reed, William R; Cao, Dong-Yuan; Long, Cynthia R; Kawchuk, Gregory N; Pickar, Joel G

    2013-01-01

    High velocity low amplitude spinal manipulation (HVLA-SM) is used frequently to treat musculoskeletal complaints. Little is known about the intervention's biomechanical characteristics that determine its clinical benefit. Using an animal preparation, we determined how neural activity from lumbar muscle spindles during a lumbar HVLA-SM is affected by the type of thrust control and by the thrust's amplitude, duration, and rate. A mechanical device was used to apply a linear increase in thrust displacement or force and to control thrust duration. Under displacement control, neural responses during the HVLA-SM increased in a fashion graded with thrust amplitude. Under force control neural responses were similar regardless of the thrust amplitude. Decreasing thrust durations at all thrust amplitudes except the smallest thrust displacement had an overall significant effect on increasing muscle spindle activity during the HVLA-SMs. Under force control, spindle responses specifically and significantly increased between thrust durations of 75 and 150 ms suggesting the presence of a threshold value. Thrust velocities greater than 20-30 mm/s and thrust rates greater than 300 N/s tended to maximize the spindle responses. This study provides a basis for considering biomechanical characteristics of an HVLA-SM that should be measured and reported in clinical efficacy studies to help define effective clinical dosages.

  12. Grip pressure measurements during activities of daily life

    Science.gov (United States)

    Sanford, Joe; Young, Carolyn; Popa, Dan; Bugnariu, Nicoleta; Patterson, Rita

    2014-06-01

    Research has expanded human-machine communication methods past direct programming and standard hand- held joystick control. Individual force sensors have been used as a simple means of providing environmental information to a robot and research has shown that more advanced sensitive skins can be viable input devices. These touch sensitive surfaces allow for additional modes of interaction between machines in open, undefined environments. These interactions include object detection for navigation and safety but can also be used for recognition of users command gestures by their machine partner. Key to successful implementation of these gestures is the understanding of varied strategies used for communication and interaction and the development of performance limits. Data of dominant hand grip forces was collected using a Tekscan Grip VersaTek Pressure Measurement System during opening of a door. Analysis of data from 10 male and female subjects is presented. The results of qualitative and quantitative analysis of these data show variability in hand configurations between users. Average data over the cohort is reported. These data will be used in future work to provide human metrology constraints and limits for use in simulation and design of new, physical human-robot interaction systems.

  13. Analysis of the statistical methods used to detect submaximal effort with the five-rung grip strength test.

    Science.gov (United States)

    Shechtman, Orit; Gutierrez, Zeida; Kokendofer, Emily

    2005-01-01

    Controversy exists in the literature concerning the ability of the five-rung grip test to identify submaximal effort. The purpose of this study was to analyze four methods commonly used to evaluate the shape of the curve generated by maximal versus submaximal efforts. Thirty hand therapy patients performed the five-rung grip test maximally and submaximally with both their injured and uninjured hands. Grip strength scores were recorded at each of the five-rung positions. Next, four methods were used to analyze the data 1) visual analysis, 2) analysis of variance, 3) normalization, and 4) calculation of the standard deviation across the five strength scores. Analysis by all methods demonstrated that there were no differences between the injured hand exerting maximal effort and the uninjured hand exerting submaximal effort. In all four methods, the five-rung grip strength test was unable to distinguish between the injured hand exerting maximal effort and the uninjured hand exerting submaximal effort. The results suggest that the five-rung grip strength test should not be used to determine sincerity of effort in people with hand injuries, and that the shape of the curve generated by the five-rung grip strength test may not be related to level of effort but rather to the amount of force generated by the gripping hand.

  14. Força de preensão palmar e pinça digital em diferentes grupos de pilotos da Academia da Força Aérea brasileira Grip and pinch strength among different groups of Brazilian Air Force pilots

    Directory of Open Access Journals (Sweden)

    Gláucia Helena Gonçalves

    2010-06-01

    Full Text Available Pilotos da Academia de Força Aérea (AFA brasileira, durante vôos, realizam movimentos com grande solicitação da musculatura da mão que comanda o manche, o que pode modificar a força muscular. Este estudo teve por objetivo analisar as forças musculares isométricas de preensão palmar e pinças polpa-a-polpa, trípode e lateral de três grupos de pilotos da AFA. Foram avaliados 15 pilotos da Esquadrilha da Fumaça (EDA, 16 instrutores de vôo (PI e 6 pilotos em treinamento (PT, todos do sexo masculino. Para a avaliação, o posicionamento corporal dos pilotos seguiu a padronização da Sociedade Americana de Terapeutas da Mão e a ordem dos movimentos analisados foi predefinida, evitando fadiga muscular. A força muscular isométrica máxima foi coletada em uma contração sustentada por 6 segundos. Os resultados mostram diferenças significativas na preensão, com superioridade das mãos dominantes em relação às não-dominantes em todos os grupos, tendo ainda o grupo EDA obtido valores significativamente superiores em relação aos demais. Nas medidas da pinça trípode, o grupo EDA apresentou significativos valores superiores aos do grupo PT, sendo encontrados valores das mãos dominantes superiores aos das não-dominantes nos grupos EDA e PI. Conclui-se que o treino específico da musculatura da mão durante o vôo, a especificidade e o período de treinamento interferem na força muscular isométrica da mão.Pilots from Brazilian Air Force Academy (AFA perform strentgth- and accuracy-demanding hand movements, which may modify muscle strength. The aim of this study was to analyse hand isometric strength of grip and pulp-to-pulp, tripode and lateral pinch in three groups of male AFA pilots: ADS (Air Demonstration Squadron, n=15; IP (instructor pilots, n=16; and TP (training pilots, n=6. Pilots body positioning during tests followed the standards of the American Society of Hand Therapists; the sequence of assessed movements was

  15. Grip type and task goal modify reach-to-grasp performance in post-stroke hemiparesis

    Science.gov (United States)

    Schaefer, Sydney Y.; DeJong, Stacey L.; Cherry, Kendra M.; Lang, Catherine E.

    2011-01-01

    This study investigated whether grip type and/or task goal influenced reaching and grasping performance in post-stroke hemiparesis. Sixteen adults with post-stroke hemiparesis and twelve healthy adults reached to and grasped a cylindrical object using one of two grip types (3-finger or palmar) to achieve one of two task goals (hold or lift). Performance of the stroke group was characteristic of hemiparetic limb movement during reach-to-grasp, with more curved handpaths and slower velocities compared to the control group. These effects were present regardless of grip type or task goal. Other measures of reaching (reach time and reach velocity at object contact) and grasping (peak thumb-index finger aperture during the reach and peak grip force during the grasp) were differentially affected by grip type, task goal, or both, despite the presence of hemiparesis, providing new evidence that changes in motor patterns after stroke may occur to compensate for stroke-related motor impairment. PMID:22357103

  16. Slip detection and grip adjustment using optical tracking in prosthetic hands.

    Science.gov (United States)

    Roberts, Luke; Singhal, Girish; Kaliki, Rahul

    2011-01-01

    We have designed a closed loop control system that adjusts the grasping force of a prosthetic hand based on the amount of object slip detected by an optical tracking sensor. The system was designed for the i-Limb (a multi-fingered prosthetic hand from Touch Bionics Inc.) and is comprised of an optical sensor embedded inside a silicone prosthetic glove and a control algorithm. In a proof of concept study to demonstrate the effectiveness of optical tracking in slip sensing, we record slip rate while increasing the weight held in the grasp of the hand and compare two cases: grip adjustment on and grip adjustment off. The average slip rate was found to be 0.314 slips/(s · oz) without grip adjustment and 0.0411 slips/(s · oz) with grip adjustment. This paper discusses the advantages of the optical approach in slip detection and presents the experiment and results utilizing the optical sensor and grip control algorithm.

  17. Statistical framework for evaluation of climate model simulations by use of climate proxy data from the last millennium – Part 3: Practical considerations, relaxed assumptions, and using tree-ring data to address the amplitude of solar forcing

    Directory of Open Access Journals (Sweden)

    A. Moberg

    2014-06-01

    Full Text Available Practical issues arise when applying a statistical framework for unbiased ranking of alternative forced climate model simulations by comparison with climate observations from instrumental and proxy data (Part 1 in this series. Given a set of model and observational data, several decisions need to be made; e.g. concerning the region that each proxy series represents, the weighting of different regions, and the time resolution to use in the analysis. Objective selection criteria cannot be made here, but we argue to study how sensitive the results are to the choices made. The framework is improved by the relaxation of two assumptions; to allow autocorrelation in the statistical model for simulated climate variability, and to enable direct comparison of alternative simulations to test if any of them fit the observations significantly better. The extended framework is applied to a set of simulations driven with forcings for the pre-industrial period 1000–1849 CE and fifteen tree-ring based temperature proxy series. Simulations run with only one external forcing (land-use, volcanic, small-amplitude solar, or large-amplitude solar, do not significantly capture the variability in the tree-ring data – although the simulation with volcanic forcing does so for some experiment settings. When all forcings are combined (using either the small- or large-amplitude solar forcing including also orbital, greenhouse-gas and non-volcanic aerosol forcing, and additionally used to produce small simulation ensembles starting from slightly different initial ocean conditions, the resulting simulations are highly capable of capturing some observed variability. Nevertheless, for some choices in the experiment design, they are not significantly closer to the observations than when unforced simulations are used, due to highly variable results between regions. It is also not possible to tell whether the small-amplitude or large-amplitude solar forcing causes the multiple-forcing

  18. Temperature limit values for gripping cold surfaces

    NARCIS (Netherlands)

    Malchaire, J.; Geng, Q.; Den Hartog, E.; Havenith, G.; Holmer, I.; Piette, A.; Powell, S.L.; Rintamäki, H.; Rissanen, S.

    2002-01-01

    Objectives. At the request of the European Commission and in the framework of the European Machinery Directive, research was conducted jointly in five different laboratories to develop specifications for surface temperature limit values for the gripping and handling of cold items. Methods. Four

  19. Temperature limit values for gripping cold surfaces

    NARCIS (Netherlands)

    Malchaire, J.; Geng, Q.; Den Hartog, E.; Havenith, G.; Holmer, I.; Piette, A.; Powell, S.L.; Rintamäki, H.; Rissanen, S.

    2002-01-01

    Objectives. At the request of the European Commission and in the framework of the European Machinery Directive, research was conducted jointly in five different laboratories to develop specifications for surface temperature limit values for the gripping and handling of cold items. Methods. Four hund

  20. Grip-Pattern Recognition for Smart Guns

    NARCIS (Netherlands)

    Kauffman, J.A.; Bazen, A.M.; Gerez, S.H.; Veldhuis, R.N.J.

    2003-01-01

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 x 44 piezoresistive elements has been used. An interface has been developed to acquire pr

  1. The GRIP method for collaborative roadmapping workshops

    DEFF Research Database (Denmark)

    Piirainen, Kalle

    2015-01-01

    Technology roadmapping is a well-known tool for technology management, but practical advice for facilitating collaborative roadmapping workshops is relatively scarce. To cater for this need, we have designed a method for collaborative roadmapping, dubbed the GRIP method, for facilitating group work...

  2. ANALYSIS OF POWER GRIP AND PINCH GRIP AMONG HEALTH CARE PROFESSIONALS

    Directory of Open Access Journals (Sweden)

    Zakariya M P

    2016-02-01

    Full Text Available Background: Grip and pinch strength are commonly employed indices of strength used in hand evaluations. Pinch grip and power grip strengths are used as indices of strength in hand therapy assessments. For all professions grip strength is an important criterion to be successful in their profession. Such phenomena may be explained by differences in nature of work, working environment, and objects workers handle. Method: 200 healthy subjects, satisfying the selection criteria were included and assessed with standardized procedure for power grip and pinch grip (lateral pinch, pad-pad, and tip-tip strength. They were divided in four groups, 50 group each according to profession i.e. medical surgeons, dentist, physiotherapists and nurses. Results: The mean power grip strength shows highly significant difference between medical vs. dental (p>0.01 and medical vs. physiotherapy group (p> 0.05 .The mean lateral pinch strength shows there is highly significant difference (p< 0.001 between dental vs. nursing profession and dental vs. physiotherapy group. No significant difference among other groups. The mean pad-pad pinch strength shows there is significant difference between dental vs. nursing (p< 0.05 and dental vs physiotherapy group (p< 0.05. The mean Tip-Tip pinch strength shows there is significant difference between dental vs nursing profession(p< 0.05 and dental vs. physiotherapy(p< 0.05. No significant different among other groups. Conclusion: Surgeons have highest power grip strength followed by Nursing, Physiotherapy and Dental professionals. Dentists have the maximum pinch strength in all three positions, followed by Surgeons, Nurses and Physiotherapists. Surgeons have maximum pinch strength next to Dentists.

  3. Registration of hand-grip pattern in smart gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, R.N.J.

    2006-01-01

    Secure Grip1 focuses on the development of a hand-grip pattern recognition system, as part of a smart gun. It is intended for use by the police. We collected the hand-grip data from police officers in three sessions in a row with time intervals in between. If data for training and testing come from

  4. Effect of elbow flexion, forearm rotation and upper arm abduction on MVC grip and grip endurance time.

    Science.gov (United States)

    Farooq, Mohd; Khan, Abid Ali

    2012-01-01

    This experiment was designed to know the effect of upper limb postural deviations on grip strength and grip endurance time. A full factorial design of experiment, i.e., 3 (0°, 45°, 90° abduction angles of upper arm) × 3 (45°, 90°, 135° angles of elbow flexion) × 3 (0°, -60° prone, +60° supine angles of forearm rotation) was used to find the effect of 27 combinations of postures on maximum voluntary contraction (MVC) grip strength and grip endurance time. The results showed that none of the main factors were significant on MVC grip, although there was a change in MVC grip. Grip endurance time significantly decreased with an increase in upper arm abduction. Also, grip endurance significantly increased with the elbow flexion angle and decreased with forearm rotation from neutral. These data will help designers and engineers to improve the workplace and tools to reduce the risk of injuries.

  5. Facilitation of corticospinal tract excitability by transcranial direct current stimulation combined with voluntary grip exercise.

    Science.gov (United States)

    Kim, Gi-Wook; Ko, Myoung-Hwan

    2013-08-26

    Previous studies have established that transcranial direct current stimulation (tDCS) is a powerful technique for the deliberate manipulation of the activity of human cerebral cortex. Moreover, it has also been shown that the non-exhausted voluntary motor exercise increases the excitability of corticospinal tract. We conducted this study to define the facilitation effect following anodal tDCS combined with the voluntary grip exercise as compared with single use of tDCS or voluntary grip exercise. Our result showed that the combination of anodal tDCS with voluntary grip exercise produced a 2-fold increase in the amplitude of MEP as compared with single use of anodal tDCS or voluntary grip exercise. In conclusion, our result could indicate that the treatment outcomes of brain and neurorehabilitation using tDCS would be better when tDCS is combined with the appropriate method of voluntary exercise as compared with single use of tDCS. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  6. Precision grip in congenital and acquired hemiparesis: similarities in impairments and implications for neurorehabilitation - review

    Directory of Open Access Journals (Sweden)

    Yannick eBleyenheuft

    2014-06-01

    Full Text Available Background: Patients with congenital and acquired hemiparesis incur long-term functional deficits, among which the loss of prehension that may impact their functional independence. Identifying, understanding and comparing the underlying mechanisms of prehension impairments represent an opportunity to better adapt neurorehabilitationObjective: The present review aims to provide a better understanding of precision grip deficits in congenital and acquired hemiparesis and to determine whether the severity and type of fine motor control impairments depend on whether or not the lesions are congenital or acquired in adulthood. Methods: Using combinations of the following key words: fingertip force, grip force, precision grip, cerebral palsy, stroke, pubmed and Scopus databases were used to search studies from 1984 to 2013. Results: Individuals with both congenital and acquired hemiparesis were able to some extent to use anticipatory motor control in precision grip tasks, even if this control was impaired in the paretic hand. In both congenital or acquired hemiparesis, the ability to plan efficient anticipatory motor control when the less-affected hand is used provides a possibility to remediate impairments in anticipatory motor control of the paretic hand. Conclusion: Surprisingly we observed very few differences between the results of studies in children with congenital hemiplegia and stroke patients. We suggest that the underlying specific strategies of neurorehabilitation developed for each one could benefit the other.

  7. Reliability of the grip strength coefficient of variation for detecting sincerity in normal and blocked median nerve in healthy adults.

    Science.gov (United States)

    Wachter, N J; Mentzel, M; Hütz, R; Gülke, J

    2017-04-01

    In the assessment of hand and upper limb function, detecting sincerity of effort (SOE) for grip strength is of major importance to identifying feigned loss of strength. Measuring maximal grip strength with a dynamometer is very common, often combined with calculating the coefficient of variation (CV), a measure of the variation over the three grip strength trials. Little data is available about the relevance of these measurements in patients with median nerve impairment due to the heterogeneity of patient groups. This study examined the reliability of grip strength tests as well as the CV to detect SOE in healthy subjects. The power distribution of the individual fingers and the thenar was taken into account. To assess reliability, the measurements were performed in subjects with a median nerve block to simulate a nerve injury. The ability of 21 healthy volunteers to exert maximal grip force and to deliberately exert half-maximal force to simulate reduced SOE in a power grip was examined using the Jamar(®) dynamometer. The experiment was performed in a combined setting with and without median nerve block of the same subject. The force at the fingertips of digits 2-5 and at the thenar eminence was measured with a sensor glove with integrated pressure receptors. For each measurement, three trials were recorded subsequently and the mean and CV were calculated. When exerting submaximal force, the subjects reached 50-62% of maximal force, regardless of the median nerve block. The sensor glove revealed a significant reduction of force when exerting submaximal force (P1 sensor) with (P<0.032) and without median nerve block (P<0.017). An increase in CV at submaximal force was found, although it was not significant. SOE can be detected with the CV at the little finger at using a 10% cut-off (sensitivity 0.84 and 0.92 without and with median nerve block, respectively). These findings suggest low reliability of the power grip measurement with the Jamar(®) dynamometer, as

  8. The use of clamping grips and friction pads by tree frogs for climbing curved surfaces

    Science.gov (United States)

    Ji, Aihong; Yuan, Shanshan; Hill, Iain; Wang, Huan; Barnes, W. Jon P.; Dai, Zhendong; Sitti, Metin

    2017-01-01

    Most studies on the adhesive mechanisms of climbing animals have addressed attachment against flat surfaces, yet many animals can climb highly curved surfaces, like twigs and small branches. Here we investigated whether tree frogs use a clamping grip by recording the ground reaction forces on a cylindrical object with either a smooth or anti-adhesive, rough surface. Furthermore, we measured the contact area of fore and hindlimbs against differently sized transparent cylinders and the forces of individual pads and subarticular tubercles in restrained animals. Our study revealed that frogs use friction and normal forces of roughly a similar magnitude for holding on to cylindrical objects. When challenged with climbing a non-adhesive surface, the compressive forces between opposite legs nearly doubled, indicating a stronger clamping grip. In contrast to climbing flat surfaces, frogs increased the contact area on all limbs by engaging not just adhesive pads but also subarticular tubercles on curved surfaces. Our force measurements showed that tubercles can withstand larger shear stresses than pads. SEM images of tubercles revealed a similar structure to that of toe pads including the presence of nanopillars, though channels surrounding epithelial cells were less pronounced. The tubercles' smaller size, proximal location on the toes and shallow cells make them probably less prone to buckling and thus ideal for gripping curved surfaces. PMID:28228509

  9. Maximal intermittent handgrip strategy: design and evaluation of an exercise protocol and a grip tool.

    Science.gov (United States)

    Bentley, Danielle Christine; Thomas, Scott Gordon

    2016-01-01

    Handgrip (HG) exercise has been prescribed as a lifestyle intervention to successfully reduce resting blood pressure (BP) among heterogeneous groups of participants. Current HG protocols have limited accessibility due to complicated exercise prescriptions and sophisticated required equipment. Therefore, this research describes the design and evaluation of the maximal intermittent (MINT) HG exercise strategy, consisting of both a novel exercise protocol (32×5 seconds maximal grip squeezes separated by 5 seconds of rest between sets) and an original grip tool. This research was a multistep progressive design that included 51 postmenopausal women as participants in three separate research studies. Part 1 of this research focuses on the MINT exercise protocol. A literature-informed rationale for the design of the protocol is described. This includes exercise intensity, work-to-rest ratio, and total exercise duration with reference to the unique physiology (mechanoreflex and metaboreflex) of postmenopausal women. Subsequent experimental analyses of acute responses to the MINT protocol revealed that women produced 50% of their maximum grip force with moderate cardiovascular responses (increases of systolic BP: 41.6 mmHg, diastolic BP: 20.1 mmHg, heart rate: 35.1 bpm) that remained far below the thresholds of concern identified by the American College of Sports Medicine. Part 2 of this research describes the creation of a novel grip tool, beginning with a mixed-methods assessment of participant opinions regarding two distinct in-laboratory grip tools, leading to the creation of four prototype MINT tools. Structured focus groups revealed a strong preference for MINT prototype 1 for all tool design features, including color, shape, size, and foam grip. Collectively, the result of this multistep research is a novel HG exercise strategy with enhanced accessibility by being easy to understand and simple to execute. The long-term training effectiveness of MINT as an exercise

  10. Hand grip strength in patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Jeong M

    2017-08-01

    Full Text Available Moa Jeong,1 Hyung Koo Kang,1 Pamela Song,2 Hye Kyeong Park,1 Hoon Jung,1 Sung-Soon Lee,1 Hyeon-Kyoung Koo1 1Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, 2Department of Neurology, Ilsan Paik Hospital, Inje University College of Medicine, Goyang, Republic of Korea Purpose: Hand grip strength (HGS is a simple way of predicting the risk of cardiovascular disease and all-cause mortality in the general population. However, the practical significance of grip strength in patients with COPD is uncertain. The aim of this study was to compare HGS between subjects with and without COPD and to evaluate its clinical relevance in patients with COPD by using a national survey.Methods: Data were collected from the Korean National Health and Nutrition Examination Survey. The study included 421 adults with COPD and 2,542 controls who completed questionnaires, spirometry, and a HGS test. HGS was compared between subjects with and without COPD, and the association between grip strength, lung function, and quality of life (QoL was evaluated.Results: The mean HGS was 33.3±9.1 kg in the COPD group and 29.9±9.5 kg in the non-COPD group; adjusted HGS was 30.9±0.33 kg and 30.9±0.11 kg, respectively (P=0.99. HGS was not related to forced vital capacity (β=0.04, P=0.70 or forced expiratory volume in 1 second (β=0.11, P=0.24 in multivariable analysis. HGS was independently associated with the EQ-5D index, but the relationship was stronger in the COPD group (β=0.30, P<0.001 than in the non-COPD group (β=0.21, P<0.001. The results were similar for each component of the EQ-5D, including mobility (β=-0.25, P<0.001, daily activity (β=-0.19, P=0.01, pain/discomfort (β=-0.32, P<0.001, and anxiety/depression (β=-0.16, P=0.01.Conclusion: HGS was not different between subjects with and without COPD, but was associated with QoL – including mobility, daily activity, pain/discomfort, and anxiety/depression – in patients with COPD. The

  11. Force

    CERN Document Server

    Graybill, George

    2007-01-01

    Forces are at work all around us. Discover what a force is, and different kinds of forces that work on contact and at a distance. We use simple language and vocabulary to make this invisible world easy for students to ""see"" and understand. Examine how forces ""add up"" to create the total force on an object, and reinforce concepts and extend learning with sample problems.

  12. The influence of material cues on early grasping force

    NARCIS (Netherlands)

    Bergmann Tiest, W.M.; Kappers, A.M.L.

    2014-01-01

    The object of this study was to see whether differences in texture influence grip force in the very early phase of grasping an object. Subjects were asked to pick up objects with different textures either blindfolded or sighted, while grip force was measured. Maximum force was found to be adjusted t

  13. Capillary and van der Waals interactions on CaF2 crystals from amplitude modulation AFM force reconstruction profiles under ambient conditions

    Directory of Open Access Journals (Sweden)

    Annalisa Calò

    2015-03-01

    Full Text Available There has been much interest in the past two decades to produce experimental force profiles characteristic of the interaction between nanoscale objects or a nanoscale object and a plane. Arguably, the advent of the atomic force microscope AFM was instrumental in driving such efforts because, in principle, force profiles could be recovered directly. Nevertheless, it has taken years before techniques have developed enough as to recover the attractive part of the force with relatively low noise and without missing information on critical ranges, particularly under ambient conditions where capillary interactions are believed to dominate. Thus a systematic study of the different profiles that may arise in such situations is still lacking. Here we employ the surfaces of CaF2, on which nanoscale water films form, to report on the range and force profiles that might originate by dynamic capillary interactions occurring between an AFM tip and nanoscale water patches. Three types of force profiles were observed under ambient conditions. One in which the force decay resembles the well-known inverse-square law typical of van der Waals interactions during the first 0.5–1 nm of decay, a second one in which the force decays almost linearly, in relatively good agreement with capillary force predicted by the constant chemical potential approximation, and a third one in which the attractive force is almost constant, i.e., forms a plateau, up to 3–4 nm above the surface when the formation of a capillary neck dominates the tip–sample interaction.

  14. Microspine Gripping Mechanism for Asteroid Capture

    Science.gov (United States)

    Merriam, Ezekiel G.; Berg, Andrew B.; Willig, Andrew; Parness, Aaron; Frey, Tim; Howell, Larry L.

    2016-01-01

    This paper details the development and early testing of a compliant suspension for a microspine gripper device for asteroid capture or micro-gravity percussive drilling. The microspine gripper architecture is reviewed, and a proposed microspine suspension design is presented and discussed. Prototyping methods are discussed, as well as testing methods and results. A path forward is identified from the results of the testing completed thus far. Key findings include: the microspine concept has been established as a valid architecture and the compliant suspension exhibits the desired stiffness characteristics for good gripping behavior. These developments will aid in developing the capability to grasp irregularly shaped boulders in micro-gravity.

  15. Analysis list: Grip1 [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Grip1 Blood + mm9 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Grip1.1.tsv... http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Grip1.5.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/target/Gri...p1.10.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Grip1.Blood.tsv http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/colo/Blood.gml ...

  16. Adaptive Human Control Gains During Precision Grip

    Directory of Open Access Journals (Sweden)

    Erik D. Engeberg

    2013-03-01

    Full Text Available Eight human test subjects attempted to track a desired position trajectory with an instrumented manipulandum (MN. The test subjects used the MN with three different levels of stiffness. A transfer function was developed to represent the human application of a precision grip from the data when the test subjects initially displaced the MN so as to learn the position mapping from the MN onto the display. Another transfer function was formed from the data of the remainder of the experiments, after significant displacement of the MN occurred. Both of these transfer functions accurately modelled the system dynamics for a portion of the experiments, but neither was accurate for the duration of the experiments because the human grip dynamics changed while learning the position mapping. Thus, an adaptive system model was developed to describe the learning process of the human test subjects as they displaced the MN in order to gain knowledge of the position mapping. The adaptive system model was subsequently validated following comparison with the human test subject data. An examination of the average absolute error between the position predicted by the adaptive model and the actual experimental data yielded an overall average error of 0.34mm for all three levels of stiffness.

  17. Algorithm design for grip-pattern verification in smart gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, R.N.J.; Bazen, A.M.; Ganzevoort, W.P.T.

    2005-01-01

    The Secure Grip project1 focuses on the development of a hand-grip pattern recognition system, as part of the smart gun. Its target customer is the police. To explore the authentication performance of this system, we collected data from a group of police officers, and made authentication simulations

  18. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond; Bazen, Asker; Kauffman, Joost; Hartel, Pieter

    2004-01-01

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 £ 44 piezoresistive elements is used to measure the grip pattern. An interface has been d

  19. Biometric verification based on grip-pattern recognition

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Kauffman, J.A.; Hartel, Pieter H.; Delp, Edward J.; Wong, Ping W.

    This paper describes the design, implementation and evaluation of a user-verification system for a smart gun, which is based on grip-pattern recognition. An existing pressure sensor consisting of an array of 44 x 44 piezoresistive elements is used to measure the grip pattern. An interface has been

  20. Algorithm Design for Grip-Pattern Verification in Smart Gun

    NARCIS (Netherlands)

    Shang, X.; Veldhuis, Raymond N.J.; Bazen, A.M.; Ganzevoort, W.P.T.

    2005-01-01

    The Secure Grip project1 focuses on the development of a hand-grip pattern recognition system, as part of the smart gun. Its target customer is the police. To explore the authentication performance of this system, we collected data from a group of police officers, and made authentication simulations

  1. Grip-pattern recognition: Applied to a smart gun

    NARCIS (Netherlands)

    Shang, X.

    2008-01-01

    In our work the verification performance of a biometric recognition system based on grip patterns, as part of a smart gun for use by the police ocers, has been investigated. The biometric features are extracted from a two-dimensional pattern of the pressure, exerted on the grip of a gun by the hand

  2. Grip-pattern verification for a smart gun

    NARCIS (Netherlands)

    Shang, X.; Groenland, J.P.J.; Groenland, J.P.J.; Veldhuis, Raymond N.J.

    In the biometric verification system of a smart gun, the rightful user of the gun is recognized based on grip-pattern recognition. It was found that the verification performance of grip-pattern recognition degrades strongly when the data for training and testing the classifier, respectively, have

  3. Normative data on functional grip strength of elderly in Singapore.

    Science.gov (United States)

    Mat Jais, Ita Suzana; Chan, Kai Li; Loke, Mun Kitt Austin; Abdul Rahim, Saleem; Tay, Shian Chao

    2017-02-21

    Cross-sectional study for clinical measurement. Most daily tasks require individuals to exert grip strength with torque, which can be challenging for elderly as their strength diminishes with age. We postulate that to assess the functional capacity of an individual, it is important to evaluate the functional grip strength instead of the maximal static grip strength. The objective of this cross-sectional study is to establish normative data for the functional grip strength of elderly aged 60 years and older in the Singapore population. In this study, 233 healthy subjects aged 60 years and older were recruited. Using a custom-made hand strength measurement device, the following measurements were recorded: grip strength at neutral position, grip strength with resistive pronation torque, and grip strength with resistive supination torque. Grip strengths measured for both genders decreased by 13% and 16% for males and females respectively, when pronation torque was exerted, and with supination torque, the strength decreased by 18% and 17% for males and females respectively. Normative data for the elderly population in Singapore had been established. The findings from this study can complement the existing ergonomic hand data in designing better assistive tools to improve the independent living of elderly. NA. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. Power spectrum analysis with least-squares fitting: Amplitude bias and its elimination, with application to optical tweezers and atomic force microscope cantilevers

    DEFF Research Database (Denmark)

    Nørlykke, Simon F.; Flyvbjerg, Henrik

    2010-01-01

    Optical tweezers and atomic force microscope (AFM) cantilevers are often calibrated by fitting their experimental power spectra of Brownian motion. We demonstrate here that if this is done with typical weighted least-squares methods, the result is a bias of relative size between -2/n and + 1/n....... The fitted value for the characteristic frequency is not affected by this bias. For the AFM then, force measurements are not affected provided an independent length-scale calibration is available. For optical tweezers there is no such luck, since the spring constant is found as the ratio...... of the characteristic frequency and the diffusion coefficient. We give analytical results for the weight-dependent bias for the wide class of systems whose dynamics is described by a linear (integro)differential equation with additive noise, white or colored. Examples are optical tweezers with hydrodynamic self...

  5. Study on the collision-mechanical properties of tomatoes gripped by ...

    African Journals Online (AJOL)

    STORAGESEVER

    2009-12-15

    Dec 15, 2009 ... The data of collision-mechanical property of tomatoes gripped by robot fingers are important for the gripping control of .... Figure 2a shows the process of robot fingers gripping tomato. ..... Drop test simulation of a sample.

  6. Improved Friction Joint With Self-Locking Grips

    DEFF Research Database (Denmark)

    Costache, Andrei; Glejbøl, Kristian; Sivebæk, Ion Marius

    2016-01-01

    Flexible risers are used in the oil industry to transport liquids and gas from the seafloorto extraction and production equipment at the sea surface. Ongoing research aims at using composite materials instead of steel, in order to reduce weight and increase stiffness. Ensuring an optimal load...... transfer between the composite and metal components is very important. This paper presents an improved method for anchoring a flat fiber reinforced tendon using a double grip system with self-locking grips. The novelty is the combination of new experimental results and finite element (FE) analysis...... to develop asuperior dry friction grip. Experimental results are carried using a dedicated test setup, through which the test parameters can be accurately controlled. The efficiency of the grip system during pullout is superior to results obtained with flat grips. Numerical results offer an in...

  7. Maximal intermittent handgrip strategy: design and evaluation of an exercise protocol and a grip tool

    Directory of Open Access Journals (Sweden)

    Bentley DC

    2016-05-01

    Full Text Available Danielle Christine Bentley, Scott Gordon Thomas Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, Ontario, Canada Abstract: Handgrip (HG exercise has been prescribed as a lifestyle intervention to successfully reduce resting blood pressure (BP among heterogeneous groups of participants. Current HG protocols have limited accessibility due to complicated exercise prescriptions and sophisticated required equipment. Therefore, this research describes the design and evaluation of the maximal intermittent (MINT HG exercise strategy, consisting of both a novel exercise protocol (32×5 seconds maximal grip squeezes separated by 5 seconds of rest between sets and an original grip tool. This research was a multistep progressive design that included 51 postmenopausal women as participants in three separate research studies. Part 1 of this research focuses on the MINT exercise protocol. A literature-informed rationale for the design of the protocol is described. This includes exercise intensity, work-to-rest ratio, and total exercise duration with reference to the unique physiology (mechanoreflex and metaboreflex of postmenopausal women. Subsequent experimental analyses of acute responses to the MINT protocol revealed that women produced 50% of their maximum grip force with moderate cardiovascular responses (increases of systolic BP: 41.6 mmHg, diastolic BP: 20.1 mmHg, heart rate: 35.1 bpm that remained far below the thresholds of concern identified by the American College of Sports Medicine. Part 2 of this research describes the creation of a novel grip tool, beginning with a mixed-methods assessment of participant opinions regarding two distinct in-laboratory grip tools, leading to the creation of four prototype MINT tools. Structured focus groups revealed a strong preference for MINT prototype 1 for all tool design features, including color, shape, size, and foam grip. Collectively, the result of this multistep

  8. Electron acceleration and emission in a field of a plane and converging dipole wave of relativistic amplitudes with the radiation reaction force taken into account

    Science.gov (United States)

    Bashinov, Aleksei V.; Gonoskov, Arkady A.; Kim, A. V.; Marklund, Mattias; Mourou, G.; Sergeev, Aleksandr M.

    2013-04-01

    A comparative analysis is performed of the electron emission characteristics as the electrons move in laser fields with ultra-relativistic intensity and different configurations corresponding to a plane or tightly focused wave. For a plane travelling wave, analytical expressions are derived for the emission characteristics, and it is shown that the angular distribution of the radiation intensity changes qualitatively even when the wave intensity is much less than that in the case of the radiation-dominated regime. An important conclusion is drawn that the electrons in a travelling wave tend to synchronised motion under the radiation reaction force. The characteristic features of the motion of electrons are found in a converging dipole wave, associated with the curvature of the phase front and nonuniformity of the field distribution. The values of the maximum achievable longitudinal momenta of electrons accelerated to the centre, as well as their distribution function are determined. The existence of quasi-periodic trajectories near the focal region of the dipole wave is shown, and the characteristics of the emission of both accelerated and oscillating electrons are analysed.

  9. Effect of skin hydration on the dynamics of fingertip gripping contact

    Science.gov (United States)

    André, T.; Lévesque, V.; Hayward, V.; Lefèvre, P.; Thonnard, J.-L.

    2011-01-01

    The dynamics of fingertip contact manifest themselves in the complex skin movements observed during the transition from a stuck state to a fully developed slip. While investigating this transition, we found that it depended on skin hydration. To quantify this dependency, we asked subjects to slide their index fingertip on a glass surface while keeping the normal component of the interaction force constant with the help of visual feedback. Skin deformation inside the contact region was imaged with an optical apparatus that allowed us to quantify the relative sizes of the slipping and sticking regions. The ratio of the stuck skin area to the total contact area decreased linearly from 1 to 0 when the tangential force component increased from 0 to a maximum. The slope of this relationship was inversely correlated to the normal force component. The skin hydration level dramatically affected the dynamics of the contact encapsulated in the course of evolution from sticking to slipping. The specific effect was to reduce the tendency of a contact to slip, regardless of the variations of the coefficient of friction. Since grips were more unstable under dry skin conditions, our results suggest that the nervous system responds to dry skin by exaggerated grip forces that cannot be simply explained by a change in the coefficient of friction. PMID:21490002

  10. Effect of syllable articulation on precision and power grip performance.

    Directory of Open Access Journals (Sweden)

    Lari Vainio

    Full Text Available The present study was motivated by a theory, which proposes that speech includes articulatory gestures that are connected to particular hand actions. We hypothesized that certain articulatory gestures would be more associated with the precision grip than with the power grip, and vice versa. In the study, the participants pronounced a syllable and performed simultaneously a precision or power grip that was theorized to be either congruent or incongruent with the syllable. Relatively fast precision grip responses were associated with articulatory gestures in which the tip of the tongue contacted the alveolar ridge ([te] or the aperture of the vocal tract remained small ([hi], as well as gestures that required lip protrusion ([pu]. In contrast, relatively fast power grip responses were associated with gestures that were produced by moving the back of the tongue against the velum ([ke] or in which the aperture of the vocal tract remained large ([hα]. In addition to demonstrating that certain articulatory gestures are systematically connected to different grip types, the study may shed some light on discussion concerning sound symbolism and evolution of speech.

  11. Grip op werkstress. Mindfulness ontstresst maatschappelijk werkers

    Directory of Open Access Journals (Sweden)

    Jen van Horen

    2014-03-01

    Full Text Available Taking control over work related stress. Mindfulness destresses social workersStress is a major social problem. Due to the increasing workload and the content of the work, social workers are at risk to develop stress (symptoms. The physical and psychological consequences of prolonged stress are serious. By living healthy, optimize working conditions and applying mindfulness, stress can be reduced. Mindfulness is an effective and useful way to reduce stress. It increases the resistance of workers against stress, improves brainfunctions and therefore has a positive effect on the performance. These effects are great, but they are still weakly methodologically substantiated. A pilot project within the youthcare though, was enthusiastically received and proves to be effective against stress symptoms. The exercises that are part of this pilot fit well with the needs of employees. For organizations mindfulnesstrainings are a time-and cost-effective way of structural stress prevention.Grip op werkstress. Mindfulness ontstresst maatschappelijk werkersStress is een omvangrijk maatschappelijk probleem. Door de toenemende werkdruk en de inhoud van het werk zijn maatschappelijk werkers een risicogroep om stress en stressklachten te ontwikkelen. De fysieke en psychische gevolgen die langdurige stress met zich meebrengt zijn ernstig. Door gezond te leven, de arbeidsomstandigheden te optimaliseren en mindfulness toe te passen kan stress terug worden gedrongen. Mindfulness is een effectieve en bruikbare manier om stress te verminderen. Het vergroot de weerbaarheid van werknemers tegen stress, het verbetert de hersenwerking en heeft daardoor een positief effect op het functioneren. Grote effecten dus, maar wel nog methodologisch zwak onderbouwd. Een pilot binnen de jeugdzorg op het gebied van mindfulness is enthousiast ontvangen en blijkt effectief tegen stressklachten. De oefeningen die onderdeel uitmaken van deze pilot sluiten goed aan bij de behoeften van

  12. Association of grip strength with cardiovascular risk markers.

    Science.gov (United States)

    Gubelmann, Cédric; Vollenweider, Peter; Marques-Vidal, Pedro

    2017-03-01

    Background Mechanisms underlying the association between grip strength and cardiovascular mortality are poorly understood. We aimed to assess the association of grip strength with a panel of cardiovascular risk markers. Design The study was based on a cross-sectional analysis of 3468 adults aged 50-75 years (1891 women) from a population-based sample in Lausanne, Switzerland. Methods Grip strength was measured using a hydraulic hand dynamometer. Cardiovascular risk markers included anthropometry, blood pressure, lipids, glucose, adiposity, inflammatory and other metabolic markers. Results In both genders, grip strength was negatively associated with fat mass (Pearson correlation coefficient: women: -0.170, men: -0.198), systolic blood pressure (women: -0.096, men: -0.074), fasting glucose (women: -0.048, men: -0.071), log-transformed leptin (women: -0.074, men: -0.065), log-transformed high-sensitivity C-reactive protein (women: -0.101, men: -0.079) and log-transformed homocysteine (women: -0.109, men: -0.060). In men, grip strength was also positively associated with diastolic blood pressure (0.068), total (0.106) and low density lipoprotein-cholesterol (0.082), and negatively associated with interleukin-6 (-0.071); in women, grip strength was negatively associated with triglycerides (-0.064) and uric acid (-0.059). After multivariate adjustment, grip strength was negatively associated with waist circumference (change per 5 kg increase in grip strength: -0.82 cm in women and -0.77 cm in men), fat mass (-0.56% in women; -0.27% in men) and high-sensitivity C-reactive protein (-6.8% in women; -3.2% in men) in both genders, and with body mass index (0.22 kg/m(2)) and leptin (-2.7%) in men. Conclusion Grip strength shows only moderate associations with cardiovascular risk markers. The effect of muscle strength as measured by grip strength on cardiovascular disease does not seem to be mediated by cardiovascular risk markers.

  13. Muscular forearm activation in hand-grip tasks with superimposition of mechanical vibrations.

    Science.gov (United States)

    Fattorini, L; Tirabasso, A; Lunghi, A; Di Giovanni, R; Sacco, F; Marchetti, E

    2016-02-01

    The purpose of this paper is to evaluate the muscular activation of the forearm, with or without vibration stimuli at different frequencies while performing a grip tasks of 45s at various level of exerted force. In 16 individuals, 9 females and 7 males, the surface electromyogram (EMG) of extensor carpi radialis longus and the flexor carpi ulnari muscles were assessed. At a short latency from onset EMG, RMS and the level of MU synchronization were assessed to evaluate the muscular adaptations. Whilst a trend of decay of EMG Median frequency (MDFd) was employed as an index of muscular fatigue. Muscular tasks consists of the grip of an instrumented handle at a force level of 20%, 30%, 40%, 60% of the maximum voluntary force. Vibration was supplied by a shaker to the hand in mono-frequential waves at 20, 30, 33 and 40Hz. In relation to EMG, RMS and MU synchronization, the muscular activation does not seem to change with the superimposition of the mechanical vibrations, on the contrary a lower MDFd was observed at 33Hz than in absence of vibration. This suggests an early muscular fatigue induced by vibration due to the fact that 33Hz is a resonance frequency for the hand-arm system.

  14. Relevance of the EMG/grip relationship in isometric anisotonic conditions.

    Science.gov (United States)

    Claudon, Laurent

    2003-01-01

    The aim of the present study was to develop a relationship to evaluate grip force using the electromyogram (EMG) in isometric anisotonic conditions. The EMGs of the flexor digitorum superficialis (FDS) and the extensor digitorum (ED) were recorded in 3 flexion-extension positions of the wrist (30 degrees flexion, 30 degrees extension, and 60 degrees extension) associated with 3 positions of the forearm (70 degrees pronation, prono-supination, and 70 degrees supination). For each position, the participants had to follow linear ramp targets (2 rates of increase and decrease) displayed on an oscilloscope. The results show the best fit is a quadratic type force-EMG relationship. Some aspects such as the rate of force variation and the forearm and wrist positions are then discussed along with the limitations of the relationship.

  15. TMS reveals a direct influence of spinal projections from human SMAp on precise force production.

    Science.gov (United States)

    Entakli, Jonathan; Bonnard, Mireille; Chen, Sophie; Berton, Eric; De Graaf, Jozina B

    2014-01-01

    The corticospinal (CS) system plays an important role in fine motor control, especially in precision grip tasks. Although the primary motor cortex (M1) is the main source of the CS projections, other projections have been found, especially from the supplementary motor area proper (SMAp). To study the characteristics of these CS projections from SMAp, we compared muscle responses of an intrinsic hand muscle (FDI) evoked by stimulation of human M1 and SMAp during an isometric static low-force control task. Subjects were instructed to maintain a small cursor on a target force curve by applying a pressure with their right precision grip on a force sensor. Neuronavigated transcranial magnetic stimulation was used to stimulate either left M1 or left SMAp with equal induced electric field values at the defined cortical targets. The results show that the SMAp stimulation evokes reproducible muscle responses with similar latencies and amplitudes as M1 stimulation, and with a clear and significant shorter silent period. These results suggest that (i) CS projections from human SMAp are as rapid and efficient as those from M1, (ii) CS projections from SMAp are directly involved in control of the excitability of spinal motoneurons and (iii) SMAp has a different intracortical inhibitory circuitry. We conclude that human SMAp and M1 both have direct influence on force production during fine manual motor tasks. © 2013 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  16. Coordination of precision grip in 2-6 year-old children with autism spectrum disorders compared to children developing typically and children with developmental disabilities

    Directory of Open Access Journals (Sweden)

    Fabian Jude David

    2012-12-01

    Full Text Available Impaired motor coordination is prevalent in children with Autism Spectrum Disorders (ASD and affects adaptive skills. Little is known about the development of motor patterns in young children with ASD between 2 and 6 years of age. The purpose of the current study was threefold: 1 to describe developmental correlates of motor coordination in children with ASD, 2 to identify the extent to which motor coordination deficits are unique to ASD by using a control group of children with other developmental disabilities (DD, and 3 to determine the association between motor coordination variables and functional fine motor skills. Twenty-four children with ASD were compared to 30 children with typical development (TD and 11 children with DD. A precision grip task was used to quantify and analyze motor coordination. The motor coordination variables were two temporal variables (grip to load force onset latency and time to peak grip force and two force variables (grip force at onset of load force and peak grip force. Functional motor skills were assessed using the Fine Motor Age Equivalents of the Vineland Adaptive Behavior Scale and the Mullen Scales of Early Learning. Mixed regression models were used for all analyses. Children with ASD presented with significant motor coordination deficits only on the two temporal variables, and these variables differentiated children with ASD from the children with TD, but not from children with DD. Fine motor functional skills had no statistically significant associations with any of the motor coordination variables. These findings suggest that subtle problems in the timing of motor actions, possibly related to maturational delays in anticipatory feed-forward mechanisms, may underlie some motor deficits reported in children with ASD, but that these issues are not unique to this population. Further research is needed to investigate how children with ASD or DD compensate for motor control deficits to establish functional

  17. G×E Interaction Influences Trajectories of Hand Grip Strength

    DEFF Research Database (Denmark)

    Petersen, Inge; Pedersen, Nancy L; Rantanen, Taina;

    2016-01-01

    and Environment across Multiple Studies consortium. Growth curve parameters were estimated for same-sex pairs, aged 34-99 (N = 10,681). Fisher's test for mixture distribution of within-monozygotic twin-pair differences (N = 1724) was performed on growth curve parameters. We observed significant gene......-environment interaction on grip strength trajectories. Finally, we compared the variability of within-pair differences of growth curve parameters by APOE haplotypes. Though not statistically significant, the results suggested that APOE ɛ2ɛ2/ɛ2ɛ3 haplotypes might buffer environmental influences on grip strength...

  18. Study of Silicon Photomultipliers for the GRIPS Calorimeter Module

    Directory of Open Access Journals (Sweden)

    Alexei Ulyanov

    2013-01-01

    Full Text Available GRIPS is a proposed gamma-ray (200 keV to 80 MeV astronomy mission, which incorporates a pair-creation and Compton scattering telescope, along with X-ray and infrared telescopes. It will carry out a sensitive all-sky scanning survey, investigating phenomena such as gamma-ray bursts, blazars and core collapse supernovae. The main telescope is composed of a Si strip detector surroundedby a calorimeter with a fast scintillator material. We present the initial results of a study which considers the potential use of silicon photomultipliers in conjunction with the scintillator in the GRIPS calorimeter module.

  19. A COMPARATIVE STUDY TO FIND OUT IMMEDIATE EFFECTIVENESS OF MOVEMENT WITH MOBILIZATION VERSUS ELBOW ORTHOSIS ON PAIN AND GRIP STRENGTH IN LATERAL EPICONDYLITIS IN HOUSEWIVES

    Directory of Open Access Journals (Sweden)

    Trishna Kakati

    2015-12-01

    both Mulligan’s MWM technique and counter force elbow orthosis produces significant decrease in pain and improvement in grip strength immediately after treatment. It has been seen that Mulligan’s MWM is better than counter force elbow orthosis in relieving pain (p=0.03. Increase in hand grip strength does not differ remarkably in both treatment groups.

  20. High Amplitude Secondary Mass Drive

    Energy Technology Data Exchange (ETDEWEB)

    DYCK,CHRISTOPHER WILLIAM; ALLEN,JAMES J.; HUBER,ROBERT JOHN; SNIEGOWSKI,JEFFRY J.

    2000-07-06

    In this paper we describe a high amplitude electrostatic drive for surface micromachined mechanical oscillators that may be suitable for vibratory gyroscopes. It is an advanced design of a previously reported dual mass oscillator (Dyck, et. al., 1999). The structure is a 2 degree-of-freedom, parallel-plate driven motion amplifier, termed the secondary mass drive oscillator (SMD oscillator). During each cycle the device contacts the drive plates, generating large electrostatic forces. Peak-to-peak amplitudes of 54 {micro}m have been obtained by operating the structure in air with an applied voltage of 11 V. We describe the structure, present the analysis and design equations, and show recent results that have been obtained, including frequency response data, power dissipation, and out-of- plane motion.

  1. Amplitudes, acquisition and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bloor, Robert

    1998-12-31

    Accurate seismic amplitude information is important for the successful evaluation of many prospects and the importance of such amplitude information is increasing with the advent of time lapse seismic techniques. It is now widely accepted that the proper treatment of amplitudes requires seismic imaging in the form of either time or depth migration. A key factor in seismic imaging is the spatial sampling of the data and its relationship to the imaging algorithms. This presentation demonstrates that acquisition caused spatial sampling irregularity can affect the seismic imaging and perturb amplitudes. Equalization helps to balance the amplitudes, and the dealing strategy improves the imaging further when there are azimuth variations. Equalization and dealiasing can also help with the acquisition irregularities caused by shot and receiver dislocation or missing traces. 2 refs., 2 figs.

  2. Prosthetic Hand With Two Gripping Fingers

    Science.gov (United States)

    Norton, William E.; Belcher, Jewell B.; Vest, Thomas W.; Carden, James R.

    1993-01-01

    Prosthetic hand developed for amputee who retains significant portion of forearm. Outer end of device is end effector including two fingers, one moved by rotating remaining part of forearm about its longitudinal axis. Main body of end effector is end member supporting fingers, roller bearing assembly, and rack-and-pinion mechanism. Advantage of rack-and-pinion mechanism enables user to open or close gap between fingers with precision and force.

  3. Grip and Pinch Strength Norms for Michigan Workers

    Directory of Open Access Journals (Sweden)

    Joel M. Phillips M.S., OTRL

    2013-06-01

    Full Text Available The purpose of this study was to create a norm reference of current grip and pinch strength norms for working-age Michigan adults. This normative study included a convenience sample of 179 volunteers who were employees at car plants in South East Michigan or hospital sites in West Michigan. Participants’ ages ranged from between 20 and 62 years of age with a mean age of 49.15 years. There were 78 females (44% and 101 males (56%. Subjects were classified by gender and in the age categories of ages 20 to 49 years and ages 50-62 years. Grip and pinch strength norms were collected following the American Society of Hand Therapy protocol. The norms from these working adults were calculated with descriptive statistics for males and females in two age classifications: ages 20 to 49 and ages 50 to 62 years. Standard Errors (SE are better than the 1985 norms for both males and females ages 20 to 49 years. SEs are higher than the ages 20 to 49 years’ norms for the ages 50 to 62 years age categories in both males and females. These norms offer a point of comparison for clinicians to use for clients in Michigan who are ages 20 to 62 years and who have a goal to improve their grip strength. Clients’ grip and pinch strength could be compared to their age level or gender norms using the comparison for one standard deviation above, below, or at the means.

  4. Gripped by movies: From story-world to artifact absorption

    NARCIS (Netherlands)

    Doicaru, M.M.

    2016-01-01

    That movies are a great source of entertainment seems to be common sense. But how exactly movies manage to get large audiences absorbed, or what is their gripping tool is still a mystery. Research makes use of different concepts pointing to narrative absorption, but it is not clear how they differ f

  5. Hand Grip Strength Vs. Sprint Effectiveness in Amputee Soccer Players

    Directory of Open Access Journals (Sweden)

    Wieczorek Marta

    2015-12-01

    Full Text Available Amputee soccer is one of the types of soccer designed for the disabled, especially those who have undergone amputations, as well as those with extremity dysfunction. The objective of the study was to find the relationship between hand grip strength and sprint time in amputee soccer players. Thirteen field amputee soccer players participated in the study. A SAEHAN hydraulic hand dynamometer manufactured by Jamar was used for hand grip strength measurements. The sprint running test was conducted over a distance of 30 m. The Fusion Smart Speed System was employed for running time measurements. No statistically significant relationships were found between hand grip strength of the left or right hand, and sprint times over 1, 5, 10, 15, 20, 25 and 30 m. Analysis of the running velocity curve of the subjects showed an interesting profile characterized by a 15 meter-long acceleration phase and a significant velocity increase over a distance of 20 – 25 m. The study suggests that there is no relationship between hand grip strength and sprint effectiveness in amputee soccer players. The specificity of locomotion with the use of elbow crutches among elite Polish amputee soccer players probably accounts for the profile of the sprint velocity curve. Extension of the acceleration phase in the sprint run and a velocity increase in the subsequent part of the run were observed.

  6. Effects of intermanual transfer induced by repetitive precision grip on input-output properties of untrained contralateral limb muscles.

    Science.gov (United States)

    Liang, Nan; Takahashi, Makoto; Ni, Zhen; Yahagi, Susumu; Funase, Kozo; Kato, Takashi; Kasai, Tatsuya

    2007-10-01

    Although there were many reports relating to intermanual transfer of behavioral motor tasks in humans, it is still not well-known whether the transfer phenomenon between the trained and untrained hand is accompanied by corresponding changes in motor system. In the present study we applied transcranial magnetic stimulation to investigate the practice effects of unilateral fingertip precision grip on corticospinal excitability, regarding both the trained and untrained hand muscles. The results showed that after practice fingertip grip force became steady and safety margin dramatically decreased not only in the trained hand, but also in the untrained hand. Regarding MEP and background EMG (B.EMG) activities, the regression slope of MEP/B.EMG ratio in the first dorsal interosseous (FDI) muscle became significantly steeper after practice in both hands, but in the thenar (TH) muscle there were no clear modulations. These results indicated that through practice qualitative or functional changes of corticospinal systems related to the reorganization for a fingertip precision grip prominently reflect only on FDI muscle which plays a dominant role in the task. More importantly, such effects were simultaneously seen in the untrained hand correspondent to the trained hand, i.e., changes of input-output property in M1 occur not only in the trained hand, but also in the untrained hand. Based on the present results, we suggest that training-induced neural adaptations of the central nervous system may include improvement of its predicting fingertip grip force for self-lifting of the object in the untrained hand.

  7. Real topological string amplitudes

    Science.gov (United States)

    Narain, K. S.; Piazzalunga, N.; Tanzini, A.

    2017-03-01

    We discuss the physical superstring correlation functions in type I theory (or equivalently type II with orientifold) that compute real topological string amplitudes. We consider the correlator corresponding to holomorphic derivative of the real topological amplitude G_{χ } , at fixed worldsheet Euler characteristic χ. This corresponds in the low-energy effective action to N=2 Weyl multiplet, appropriately reduced to the orientifold invariant part, and raised to the power g' = -χ + 1. We show that the physical string correlator gives precisely the holomorphic derivative of topological amplitude. Finally, we apply this method to the standard closed oriented case as well, and prove a similar statement for the topological amplitude F_g.

  8. Force-independent distribution of correlated neural inputs to hand muscles during three-digit grasping.

    Science.gov (United States)

    Poston, Brach; Danna-Dos Santos, Alessander; Jesunathadas, Mark; Hamm, Thomas M; Santello, Marco

    2010-08-01

    The ability to modulate digit forces during grasping relies on the coordination of multiple hand muscles. Because many muscles innervate each digit, the CNS can potentially choose from a large number of muscle coordination patterns to generate a given digit force. Studies of single-digit force production tasks have revealed that the electromyographic (EMG) activity scales uniformly across all muscles as a function of digit force. However, the extent to which this finding applies to the coordination of forces across multiple digits is unknown. We addressed this question by asking subjects (n = 8) to exert isometric forces using a three-digit grip (thumb, index, and middle fingers) that allowed for the quantification of hand muscle coordination within and across digits as a function of grasp force (5, 20, 40, 60, and 80% maximal voluntary force). We recorded EMG from 12 muscles (6 extrinsic and 6 intrinsic) of the three digits. Hand muscle coordination patterns were quantified in the amplitude and frequency domains (EMG-EMG coherence). EMG amplitude scaled uniformly across all hand muscles as a function of grasp force (muscle x force interaction: P = 0.997; cosines of angle between muscle activation pattern vector pairs: 0.897-0.997). Similarly, EMG-EMG coherence was not significantly affected by force (P = 0.324). However, coherence was stronger across extrinsic than that across intrinsic muscle pairs (P = 0.0039). These findings indicate that the distribution of neural drive to multiple hand muscles is force independent and may reflect the anatomical properties or functional roles of hand muscle groups.

  9. Role of across‐muscle motor unit synchrony for the coordination of forces

    OpenAIRE

    Santello, Marco; Fuglevand, Andrew J.

    2004-01-01

    Evidence from five‐digit grasping studies indicates that grip forces exerted by pairs of digits tend to be synchronized. It has been suggested that motor unit synchronization might be a mechanism responsible for constraining the temporal relationships between grip forces. To evaluate this possibility and quantify the effect of motor unit synchrony on force relationships, we used a motor unit model to simulate force produced by two muscles using three physiological levels of motor unit synchro...

  10. GRiP - A flexible approach for calculating risk as a function of consequence, vulnerability, and threat.

    Energy Technology Data Exchange (ETDEWEB)

    Whitfield, R. G.; Buehring, W. A.; Bassett, G. W. (Decision and Information Sciences)

    2011-04-08

    Get a GRiP (Gravitational Risk Procedure) on risk by using an approach inspired by the physics of gravitational forces between body masses! In April 2010, U.S. Department of Homeland Security Special Events staff (Protective Security Advisors [PSAs]) expressed concern about how to calculate risk given measures of consequence, vulnerability, and threat. The PSAs believed that it is not 'right' to assign zero risk, as a multiplicative formula would imply, to cases in which the threat is reported to be extremely small, and perhaps could even be assigned a value of zero, but for which consequences and vulnerability are potentially high. They needed a different way to aggregate the components into an overall measure of risk. To address these concerns, GRiP was proposed and developed. The inspiration for GRiP is Sir Isaac Newton's Universal Law of Gravitation: the attractive force between two bodies is directly proportional to the product of their masses and inversely proportional to the squares of the distance between them. The total force on one body is the sum of the forces from 'other bodies' that influence that body. In the case of risk, the 'other bodies' are the components of risk (R): consequence, vulnerability, and threat (which we denote as C, V, and T, respectively). GRiP treats risk as if it were a body within a cube. Each vertex (corner) of the cube represents one of the eight combinations of minimum and maximum 'values' for consequence, vulnerability, and threat. The risk at each of the vertices is a variable that can be set. Naturally, maximum risk occurs when consequence, vulnerability, and threat are at their maximum values; minimum risk occurs when they are at their minimum values. Analogous to gravitational forces among body masses, the GRiP formula for risk states that the risk at any interior point of the box depends on the squares of the distances from that point to each of the eight vertices. The risk

  11. Secondary threshold amplitudes for sinuous streak breakdown

    Science.gov (United States)

    Cossu, Carlo; Brandt, Luca; Bagheri, Shervin; Henningson, Dan S.

    2011-07-01

    The nonlinear stability of laminar sinuously bent streaks is studied for the plane Couette flow at Re = 500 in a nearly minimal box and for the Blasius boundary layer at Reδ*=700. The initial perturbations are nonlinearly saturated streamwise streaks of amplitude AU perturbed with sinuous perturbations of amplitude AW. The local boundary of the basin of attraction of the linearly stable laminar flow is computed by bisection and projected in the AU - AW plane providing a well defined critical curve. Different streak transition scenarios are seen to correspond to different regions of the critical curve. The modal instability of the streaks is responsible for transition for AU = 25%-27% for the considered flows, where sinuous perturbations of amplitude below AW ≈ 1%-2% are sufficient to counteract the streak viscous dissipation and induce breakdown. The critical amplitude of the sinuous perturbations increases when the streamwise streak amplitude is decreased. With secondary perturbations amplitude AW ≈ 4%, breakdown is induced on stable streamwise streaks with AU ≈ 13%, following the secondary transient growth scenario first examined by Schoppa and Hussain [J. Fluid Mech. 453, 57 (2002)]. A cross-over, where the critical amplitude of the sinuous perturbation becomes larger than the amplitude of streamwise streaks, is observed for streaks of small amplitude AU < 5%-6%. In this case, the transition is induced by an initial transient amplification of streamwise vortices, forced by the decaying sinuous mode. This is followed by the growth of the streaks and final breakdown. The shape of the critical AU - AW curve is very similar for Couette and boundary layer flows and seems to be relatively insensitive to the nature of the edge states on the basin boundary. The shape of this critical curve indicates that the stability of streamwise streaks should always be assessed in terms of both the streak amplitude and the amplitude of spanwise velocity perturbations.

  12. Protostring scattering amplitudes

    Science.gov (United States)

    Thorn, Charles B.

    2016-11-01

    We calculate some tree-level scattering amplitudes for a generalization of the protostring, which is a novel string model implied by the simplest string bit models. These bit models produce a light-cone world sheet which supports s integer moded Grassmann fields. In the generalization we supplement this Grassmann world-sheet system with d =24 -s transverse coordinate world-sheet fields. The protostring corresponds to s =24 and the bosonic string to s =0 . The interaction vertex is a simple overlap with no operator insertions at the break/join point. Assuming that s is even we calculate the multistring scattering amplitudes by bosonizing the Grassmann fields, each pair equivalent to one compactified bosonic field, and applying Mandelstam's interacting string formalism to a system of s /2 compactified and d uncompactified bosonic world-sheet fields. We obtain all amplitudes for open strings with no oscillator excitations and for closed strings with no oscillator excitations and zero winding number. We then study in detail some simple special cases. Multistring processes with maximal helicity violation have much simpler amplitudes. We also specialize to general four-string amplitudes and discuss their high energy behavior. Most of these models are not covariant under the full Lorentz group O (d +1 ,1 ). The exceptions are the bosonic string whose Lorentz group is O (25 ,1 ) and the protostring whose Lorentz group is O (1 ,1 ). The models in between only enjoy an O (1 ,1 )×O (d ) spacetime symmetry.

  13. Rapamycin increases grip strength and attenuates age-related decline in maximal running distance in old low capacity runner rats.

    Science.gov (United States)

    Xue, Qian-Li; Yang, Huanle; Li, Hui-Fen; Abadir, Peter M; Burks, Tyesha N; Koch, Lauren G; Britton, Steven L; Carlson, Joshua; Chen, Laura; Walston, Jeremy D; Leng, Sean X

    2016-04-01

    Rapamycin is known to extend lifespan. We conducted a randomized placebo-controlled study of enteric rapamycin-treatment to evaluate its effect on physical function in old low capacity runner (LCR) rats, a rat model selected from diverse genetic background for low intrinsic aerobic exercise capacity without genomic manipulation and characterized by increased complex disease risks and aging phenotypes. The study was performed in 12 male and 16 female LCR rats aged 16-22 months at baseline. The treatment group was fed with rapamycin-containing diet pellets at approximately 2.24mg/kg body weight per day and the placebo group with the same diet without rapamycin for six months. Observation was extended for additional 2 months. Physical function measurements include grip strength measured as maximum tensile force using a rat grip strength meter and maximum running distance (MRD) using rat physical treadmill test. The results showed that rapamycin improved grip strength by 13% (p=.036) and 60% (p=.001) from its baseline in female and male rats, respectively. Rapamycin attenuated MRD decline by 66% (p=.001) and 46% (p=.319) in females and males, respectively. These findings provide initial evidence for beneficial effect of rapamycin on physical functioning in an aging rat model of high disease risks with significant implication in humans.

  14. Impaired anticipatory control of force sharing patterns during whole-hand grasping in Parkinson's disease.

    Science.gov (United States)

    Muratori, Lisa M; McIsaac, Tara L; Gordon, Andrew M; Santello, Marco

    2008-02-01

    We examined the coordination of multi-digit grasping forces as they developed during object grasping and lifting. Ten subjects with Parkinson's disease (PD; OFF and ON medication) and ten healthy age-matched control subjects lifted a manipulandum that measured normal forces at each digit and the manipulandum's position. The center of mass (CM) was changed from trial to trial in either a predictable (blocked) or unpredictable (random) order. All subjects modulated individual fingertip forces to counterbalance forces exerted by the thumb and minimize object tilt after lift-off. However, subjects with PD OFF exhibited an impaired ability to use anticipatory mechanisms resulting in less differentiated scaling of individual finger forces to the object CM location. Remarkably, these between-group differences in force modulation dissipated as subjects reached peak grip forces during object lift, although these occurred significantly later in subjects with PD OFF than controls and PD ON. Analysis of the tilt of the object during lift revealed all subjects had similar deviations of the object from the vertical, the direction of which depended on CM location. Thus these findings in subjects with PD indicate that: (a) PD-induced impairments in anticipatory force mechanisms appear to be greatly increased in multi-digit grasping as opposed to previous reports from two-digit grasping; (b) inaccurate scaling of fingertip force amplitude and sharing patterns before object lift is recovered during object lift; (c) the implementation of appropriate force amplitude and sharing among the digits during the lift occurs significantly later than for controls; (d) medication improves the temporal recovery of multi-digit force coordination. These results are discussed within the framework of PD-related deficits in sensorimotor integration and control of multi-degrees of freedom movement.

  15. Protostring Scattering Amplitudes

    CERN Document Server

    Thorn, Charles B

    2016-01-01

    We calculate some tree level scattering amplitudes for a generalization of the protostring, which is a novel string model implied by the simplest string bit models. These bit models produce a lightcone worldsheet which supports $s$ integer moded Grassmann fields. In the generalization we supplement this Grassmann worldsheet system with $d=24-s$ transverse coordinate worldsheet fields. The protostring corresponds to $s=24$ and the bosonic string to $s=0$. The interaction vertex is a simple overlap with no operator insertions at the break/join point. Assuming that $s$ is even we calculate the multi-string scattering amplitudes by bosonizing the Grassmann fields, each pair equivalent to one compactified bosonic field, and applying Mandelstam's interacting string formalism to a system of $s/2$ compactified and $d$ uncompactified bosonic worldsheet fields. We obtain all amplitudes for open strings with no oscillator excitations and for closed strings with no oscillator excitations and zero winding number. We then ...

  16. Effects of hyperthyroidism on hand grip strength and function.

    Science.gov (United States)

    Erkol İnal, Esra; Çarlı, Alparslan Bayram; Çanak, Sultan; Aksu, Oğuzhan; Köroğlu, Banu Kale; Savaş, Serpil

    2015-01-01

    Hyperthyroidism is a pathologic condition in which the body is exposed to excessive amounts of circulating thyroid hormones. Skeletal muscle is one of the major target organs of thyroid hormones. We evaluated hand grip strength and function in patients with overt hyperthyroidism. Fifty-one patients newly diagnosed with hyperthyroidism and 44 healthy controls participated in this study. Age, height, weight, and dominant hand of all participants were recorded. The diagnosis of hyperthyroidism was confirmed by clinical examination and laboratory tests. Hand grip strength was tested at the dominant hand with a Jamar hand dynamometer. The grooved pegboard test (PGT) was used to evaluate hand dexterity. The Duruöz Hand Index (DHI) was used to assess hand function. No significant differences were found in terms of clinical and demographic findings between the patients with hyperthyroidism and healthy controls (p > 0.05). Significant differences were found between the patients with hyperthyroidism and healthy controls regarding PGT and DHI scores (p Hyperthyroidism seemed to affect hand dexterity and function more than hand grip strength and seemed to be associated with reduced physical function more than muscle strength. This may also indicate that patients with hyperthyroidism should be evaluated by multidisplinary modalities.

  17. GRIPS - Gamma-Ray Imaging, Polarimetry and Spectroscopy

    CERN Document Server

    Greiner, J; Aharonian, F; Ajello, M; Balasz, L G; Barbiellini, G; Bellazzini, R; Bishop, S; Bisnovatij-Kogan, G S; Boggs, S; Bykov, A; DiCocco, G; Diehl, R; Elsässer, D; Foley, S; Fransson, C; Gehrels, N; Hanlon, L; Hartmann, D; Hermsen, W; Hillebrandt, W; Hudec, R; Iyudin, A; Jose, J; Kadler, M; Kanbach, G; Klamra, W; Kiener, J; Klose, S; Kreykenbohm, I; Kuiper, L M; Kylafis, N; Labanti, C; Langanke, K; Langer, N; Larsson, S; Leibundgut, B; Laux, U; Longo, F; Maeda, K; Marcinkowski, R; Marisaldi, M; McBreen, B; McBreen, S; Meszaros, A; Nomoto, K; Pearce, M; Peer, A; Pian, E; Prantzos, N; Raffelt, G; Reimer, O; Rhode, W; Ryde, F; Schmidt, C; Silk, J; Shustov, B M; Strong, A; Tanvir, N; Thielemann, F -K; Tibolla, O; Tierney, D; Trümper, J; Varshalovich, D A; Wilms, J; Wrochna, G; Zdziarski, A; Zoglauer, A

    2011-01-01

    We propose to perform a continuously scanning all-sky survey from 200 keV to 80 MeV achieving a sensitivity which is better by a factor of 40 or more compared to the previous missions in this energy range. The Gamma-Ray Imaging, Polarimetry and Spectroscopy (GRIPS) mission addresses fundamental questions in ESA's Cosmic Vision plan. Among the major themes of the strategic plan, GRIPS has its focus on the evolving, violent Universe, exploring a unique energy window. We propose to investigate $\\gamma$-ray bursts and blazars, the mechanisms behind supernova explosions, nucleosynthesis and spallation, the enigmatic origin of positrons in our Galaxy, and the nature of radiation processes and particle acceleration in extreme cosmic sources including pulsars and magnetars. The natural energy scale for these non-thermal processes is of the order of MeV. Although they can be partially and indirectly studied using other methods, only the proposed GRIPS measurements will provide direct access to their primary photons. G...

  18. A course in amplitudes

    Science.gov (United States)

    Taylor, Tomasz R.

    2017-05-01

    This a pedagogical introduction to scattering amplitudes in gauge theories. It proceeds from Dirac equation and Weyl fermions to the two pivot points of current developments: the recursion relations of Britto, Cachazo, Feng and Witten, and the unitarity cut method pioneered by Bern, Dixon, Dunbar and Kosower. In ten lectures, it covers the basic elements of on-shell methods.

  19. Weak Boson Production Amplitude Zeros; Equalities of the Helicity Amplitudes

    CERN Document Server

    Mamedov, F

    2002-01-01

    We investigate the radiation amplitude zeros exhibited by many Standard Model amplitudes for triple weak gauge boson production processes. We show that $WZ\\gamma$ production amplitudes have especially rich structure in terms of zeros, these amplitudes have zeros originating from several different sources. It is also shown that TYPE I current null zone is the special case of the equality of the specific helicity amplitudes.

  20. Periods and Superstring Amplitudes

    CERN Document Server

    Stieberger, S

    2016-01-01

    Scattering amplitudes which describe the interaction of physical states play an important role in determining physical observables. In string theory the physical states are given by vibrations of open and closed strings and their interactions are described (at the leading order in perturbation theory) by a world-sheet given by the topology of a disk or sphere, respectively. Formally, for scattering of N strings this leads to N-3-dimensional iterated real integrals along the compactified real axis or N-3-dimensional complex sphere integrals, respectively. As a consequence the physical observables are described by periods on M_{0,N} - the moduli space of Riemann spheres of N ordered marked points. The mathematical structure of these string amplitudes share many recent advances in arithmetic algebraic geometry and number theory like multiple zeta values, single-valued multiple zeta values, Drinfeld, Deligne associators, Hopf algebra and Lie algebra structures related to Grothendiecks Galois theory. We review the...

  1. Light Meson Distribution Amplitudes

    CERN Document Server

    Arthur, R.; Brommel, D.; Donnellan, M.A.; Flynn, J.M.; Juttner, A.; de Lima, H.Pedroso; Rae, T.D.; Sachrajda, C.T.; Samways, B.

    2010-01-01

    We calculated the first two moments of the light-cone distribution amplitudes for the pseudoscalar mesons ($\\pi$ and $K$) and the longitudinally polarised vector mesons ($\\rho$, $K^*$ and $\\phi$) as part of the UKQCD and RBC collaborations' $N_f=2+1$ domain-wall fermion phenomenology programme. These quantities were obtained with a good precision and, in particular, the expected effects of $SU(3)$-flavour symmetry breaking were observed. Operators were renormalised non-perturbatively and extrapolations to the physical point were made, guided by leading order chiral perturbation theory. The main results presented are for two volumes, $16^3\\times 32$ and $24^3\\times 64$, with a common lattice spacing. Preliminary results for a lattice with a finer lattice spacing, $32^3\\times64$, are discussed and a first look is taken at the use of twisted boundary conditions to extract distribution amplitudes.

  2. Quantitative Seismic Amplitude Analysis

    OpenAIRE

    Dey, A. K.

    2011-01-01

    The Seismic Value Chain quantifies the cyclic interaction between seismic acquisition, imaging and reservoir characterization. Modern seismic innovation to address the global imbalance in hydrocarbon supply and demand requires such cyclic interaction of both feed-forward and feed-back processes. Currently, the seismic value chain paradigm is in a feed-forward mode. Modern seismic data now have the potential to yield the best images in terms of spatial resolution, amplitude accuracy, and incre...

  3. Discrimination of handlebar grip samples by fourier transform infrared microspectroscopy analysis and statistics

    Directory of Open Access Journals (Sweden)

    Zeyu Lin

    2017-01-01

    Full Text Available In this paper, the authors presented a study on the discrimination of handlebar grip samples, to provide effective forensic science service for hit and run traffic cases. 50 bicycle handlebar grip samples, 49 electric bike handlebar grip samples, and 96 motorcycle handlebar grip samples have been randomly collected by the local police in Beijing (China. Fourier transform infrared microspectroscopy (FTIR was utilized as analytical technology. Then, target absorption selection, data pretreatment, and discrimination of linked samples and unlinked samples were chosen as three steps to improve the discrimination of FTIR spectrums collected from different handlebar grip samples. Principal component analysis and receiver operating characteristic curve were utilized to evaluate different data selection methods and different data pretreatment methods, respectively. It is possible to explore the evidential value of handlebar grip residue evidence through instrumental analysis and statistical treatments. It will provide a universal discrimination method for other forensic science samples as well.

  4. Capillary forces in tapping mode atomic force microscopy

    NARCIS (Netherlands)

    Zitzler, L.; Herminghaus, S.; Mugele, Friedrich Gunther

    2002-01-01

    We investigated the influence of the relative humidity on amplitude and phase of the cantilever oscillation while operating an atomic force microscope (AFM) in the tapping mode. If the free oscillation amplitude A0 exceeds a certain critical amplitude Ac, the amplitude- and phase-distance curves

  5. ANALYTICAL RESEARCH ON THE GRIP VARIATION OF TWO-AXLE CAR

    Directory of Open Access Journals (Sweden)

    Rosen IVANOV

    2016-12-01

    Full Text Available This paper presents a theoretical investigation on the decrease in grip coefficient of a car due to the car mass changes for three different running conditions- straightforward, motion in curve and braking. The grip of two types of cars - with forward and rear traction, equipped with three models of tires are studied. The results show a significant decrease of the grip coefficient in longitudinal and lateral directions.

  6. Finger pad friction and its role in grip and touch

    Science.gov (United States)

    Adams, Michael J.; Johnson, Simon A.; Lefèvre, Philippe; Lévesque, Vincent; Hayward, Vincent; André, Thibaut; Thonnard, Jean-Louis

    2013-01-01

    Many aspects of both grip function and tactile perception depend on complex frictional interactions occurring in the contact zone of the finger pad, which is the subject of the current review. While it is well established that friction plays a crucial role in grip function, its exact contribution for discriminatory touch involving the sliding of a finger pad is more elusive. For texture discrimination, it is clear that vibrotaction plays an important role in the discriminatory mechanisms. Among other factors, friction impacts the nature of the vibrations generated by the relative movement of the fingertip skin against a probed object. Friction also has a major influence on the perceived tactile pleasantness of a surface. The contact mechanics of a finger pad is governed by the fingerprint ridges and the sweat that is exuded from pores located on these ridges. Counterintuitively, the coefficient of friction can increase by an order of magnitude in a period of tens of seconds when in contact with an impermeably smooth surface, such as glass. In contrast, the value will decrease for a porous surface, such as paper. The increase in friction is attributed to an occlusion mechanism and can be described by first-order kinetics. Surprisingly, the sensitivity of the coefficient of friction to the normal load and sliding velocity is comparatively of second order, yet these dependencies provide the main basis of theoretical models which, to-date, largely ignore the time evolution of the frictional dynamics. One well-known effect on taction is the possibility of inducing stick–slip if the friction decreases with increasing sliding velocity. Moreover, the initial slip of a finger pad occurs by the propagation of an annulus of failure from the perimeter of the contact zone and this phenomenon could be important in tactile perception and grip function. PMID:23256185

  7. Grip strength in healthy caucasian adults: reference values.

    Science.gov (United States)

    Günther, Christian M; Bürger, Alexander; Rickert, Markus; Crispin, Alexander; Schulz, Christoph U

    2008-04-01

    The aim of this study was to update reference data of handgrip strength for healthy adults of both genders spanning a wide age range and to analyze possible factors of influence. Intraindividual and interindividual variations of grip strength and their relation to several anthropometric factors were analyzed in a standardized manner for 769 healthy adults (women, n = 403; men, n = 366) aged between 20 years and 95 years. Measurements were done in neutral position of arm, forearm, and wrist on setting II of a Baseline digital hydraulic dynamometer (NexGen Ergonomics Inc. Quebec, Canada). Mean strength was about 41% less in women (right 29 kg; left 27 kg) than in men (right 49 kg; left 47 kg) resulting in a ratio of left to right hand slightly above .95 in both genders. During the course of life, hand strength develops comparably in both genders peaking at 35 years of age and decreasing continuously further on. Anthropometric variables such as forearm circumference and length, hand size, or body mass showed a positive correlation with grip strength. Body mass index, type of work, and hand dominance showed only a partial positive correlation or no correlation with grip strength. Gender and age, followed by parameters representing body length and obesity, were observed to have the highest predictive value for handgrip strength and were therefore entered into the generation of prediction equations. We recommend side adjustment of measured values for intraindividual comparison and inclusion of information regarding anthropometric characteristics, as well as using gender- and age-adjusted reference values, whereas hand dominance can be neglected. The regression equations we generated might prove to be useful for clinicians or for those who use normative values within software to provide more accurate predictions of strength scores for specific applications.

  8. GRIPS - Gamma-Ray Burst Investigation via Polarimetry and Spectroscopy

    CERN Document Server

    Greiner, J

    2008-01-01

    The primary scientific goal of the GRIPS mission is to revolutionize our understanding of the early universe using gamma-ray bursts. We propose a new generation gamma-ray observatory capable of unprecedented spectroscopy over a wide range of gamma-ray energies (200 keV--50 MeV) and of polarimetry (200--1000 keV). Secondary goals achievable by this mission include direct measurements of supernova interiors through gamma-rays from radioactive decays, nuclear astrophysics with massive stars and novae, and studies of particle acceleration near compact stars, interstellar shocks, and clusters of galaxies.

  9. GRIP Database original data - GRIPDB | LSDB Archive [Life Science Database Archive metadata

    Lifescience Database Archive (English)

    Full Text Available List Contact us GRIPDB GRIP Database original data Data detail Data name GRIP Database original data DOI 10....18908/lsdba.nbdc01665-006 Description of data contents GRIP Database original data It consists of data table...s and sequences. Data file File name: gripdb_original_data.zip File URL: ftp://ftp.biosciencedbc.jp/archive/gripdb/LATEST/gripdb_orig...e Database Description Download License Update History of This Database Site Policy | Contact Us GRIP Database original data - GRIPDB | LSDB Archive ... ...inal_data.zip File size: 779 KB Simple search URL - Data

  10. Pencil grips, legibility, and speed of fourth-graders' writing in cursive.

    Science.gov (United States)

    Koziatek, Susan M; Powell, Nancy J

    2003-01-01

    The purpose of this research was to study how the speed and legibility of fourth-graders handwriting was affected by type of pencil grip on the Evaluation Tool of Children's Handwriting-Cursive. Ninety-five typically developing students and 6 students receiving special education services completed the Evaluation Tool of Children's Handwriting-Cursive (ETCH-C). Photographs were taken of their pencil grips while they wrote the alphabet. One-way ANOVAs were calculated to compare legibility rates and writing speeds by type of pencil grip. Ninety-nine of the students used one of four pencil grips including the dynamic tripod (38 students), the dynamic quadrupod (18), the lateral tripod (22), and the lateral quadrupod (21). One student used the four-finger pencil grip and one used the interdigital pencil grip. Mean cursive writing speeds were similar for all pencil grips except for the interdigital grasp. Speeds obtained were slower than recently published fourth-grade speeds ranging from a mean of 29.45 to 34.75 letters per minute. CONCLUSION. This study found the lateral quadrupod and four-finger pencil grips to be as functional as the dynamic tripod, lateral tripod, and dynamic quadrupod pencil grips. This study provides average handwriting speeds for fourth-grade students on the ETCH-C.

  11. Delayed grip relaxation and altered modulation of intracortical inhibition with aging

    Science.gov (United States)

    Motawar, Binal; Stinear, James W.; Lauer, Abigail W.; Ramakrishnan, V. Viswanathan; Seo, Na Jin

    2015-01-01

    Grip relaxation is a voluntary action that requires an increase in short-interval intracortical inhibition (SICI) in healthy young adults, rather than a simple termination of excitatory drive. The way aging affects this voluntary inhibitory action and timing of grip relaxation is currently unknown. The objective of this study was to examine aging-related delays in grip relaxation and SICI modulation for the flexor digitorum superficialis (FDS) muscle during grip relaxation. The main finding was that young adults increased SICI to relax their grips, whereas older adults did not increase SICI with a prolonged grip relaxation time (prelaxation time). A secondary experiment showed that both young and older adults did not change H reflex excitability during grip relaxation. Our data suggest that grip relaxation is mediated by increased cortical inhibitory output in young adults, and aging-related impairment in increasing cortical inhibitory output may hamper timely cessation of muscle activity. Our data also suggest a lesser role of the spinal circuits in grip muscle relaxation. This knowledge may contribute to understanding of aging-related movement deterioration and development of interventions for improving modulation of SICI to improve muscle relaxation and movement coordination. PMID:26686531

  12. Comparative study of maximum isometric grip strength in different sports

    Directory of Open Access Journals (Sweden)

    Noé Gomes Borges Junior

    2009-06-01

    Full Text Available The objective of this study was to compare maximum isometric grip strength (Fmaxbetween different sports and between the dominant (FmaxD and non-dominant (FmaxND hand. Twenty-nine male aikido (AI, jiujitsu (JJ, judo (JU and rowing (RO athletes and 21non-athletes (NA participated in the study. The hand strength test consisted of maintainingmaximum isometric grip strength for 10 seconds using a hand dynamometer. The position of the subjects was that suggested by the American Society of Hand Therapy. Factorial 2X5 ANOVA with Bonferroni correction, followed by a paired t test and Tukey test, was used for statistical analysis. The highest Fmax values were observed for the JJ group when using the dominant hand,followed by the JU, RO, AI and NA groups. Variation in Fmax could be attributed to handdominance (30.9%, sports modality (39.9% and the interaction between hand dominance andsport (21.3%. The present results demonstrated significant differences in Fmax between the JJ and AI groups and between the JJ and NA groups for both the dominant and non-dominant hand. Significant differences in Fmax between the dominant and non-dominant hand were only observed in the AI and NA groups. The results indicate that Fmax can be used for comparisonbetween different sports modalities, and to identify differences between the dominant and nondominanthand. Studies involving a larger number of subjects will permit the identification of differences between other modalities.

  13. GRiP - A flexible approach for calculating risk as a function of consequence, vulnerability, and threat.

    Energy Technology Data Exchange (ETDEWEB)

    Whitfield, R. G.; Buehring, W. A.; Bassett, G. W. (Decision and Information Sciences)

    2011-04-08

    Get a GRiP (Gravitational Risk Procedure) on risk by using an approach inspired by the physics of gravitational forces between body masses! In April 2010, U.S. Department of Homeland Security Special Events staff (Protective Security Advisors [PSAs]) expressed concern about how to calculate risk given measures of consequence, vulnerability, and threat. The PSAs believed that it is not 'right' to assign zero risk, as a multiplicative formula would imply, to cases in which the threat is reported to be extremely small, and perhaps could even be assigned a value of zero, but for which consequences and vulnerability are potentially high. They needed a different way to aggregate the components into an overall measure of risk. To address these concerns, GRiP was proposed and developed. The inspiration for GRiP is Sir Isaac Newton's Universal Law of Gravitation: the attractive force between two bodies is directly proportional to the product of their masses and inversely proportional to the squares of the distance between them. The total force on one body is the sum of the forces from 'other bodies' that influence that body. In the case of risk, the 'other bodies' are the components of risk (R): consequence, vulnerability, and threat (which we denote as C, V, and T, respectively). GRiP treats risk as if it were a body within a cube. Each vertex (corner) of the cube represents one of the eight combinations of minimum and maximum 'values' for consequence, vulnerability, and threat. The risk at each of the vertices is a variable that can be set. Naturally, maximum risk occurs when consequence, vulnerability, and threat are at their maximum values; minimum risk occurs when they are at their minimum values. Analogous to gravitational forces among body masses, the GRiP formula for risk states that the risk at any interior point of the box depends on the squares of the distances from that point to each of the eight vertices. The risk

  14. Statistical framework for evaluation of climate model simulations by use of climate proxy data from the last millennium – Part 2: A pseudo-proxy study addressing the amplitude of solar forcing

    Directory of Open Access Journals (Sweden)

    A. Hind

    2012-08-01

    Full Text Available The statistical framework of Part 1 (Sundberg et al., 2012, for comparing ensemble simulation surface temperature output with temperature proxy and instrumental records, is implemented in a pseudo-proxy experiment. A set of previously published millennial forced simulations (Max Planck Institute – COSMOS, including both "low" and "high" solar radiative forcing histories together with other important forcings, was used to define "true" target temperatures as well as pseudo-proxy and pseudo-instrumental series. In a global land-only experiment, using annual mean temperatures at a 30-yr time resolution with realistic proxy noise levels, it was found that the low and high solar full-forcing simulations could be distinguished. In an additional experiment, where pseudo-proxies were created to reflect a current set of proxy locations and noise levels, the low and high solar forcing simulations could only be distinguished when the latter served as targets. To improve detectability of the low solar simulations, increasing the signal-to-noise ratio in local temperature proxies was more efficient than increasing the spatial coverage of the proxy network. The experiences gained here will be of guidance when these methods are applied to real proxy and instrumental data, for example when the aim is to distinguish which of the alternative solar forcing histories is most compatible with the observed/reconstructed climate.

  15. Comparative study of millennials' (age 20-34 years) grip and lateral pinch with the norms.

    Science.gov (United States)

    Fain, Elizabeth; Weatherford, Cara

    Cross-sectional research design. Clinical practice continues to use normative data for grip and pinch measurements that were established in 1985. There is no updated norms despite different hand usage patterns in today's society. Measuring and comparing grip and pinch strengths with normative data is a valid method to determine hand function. This research was implemented to compare the grip and pinch measurements obtained from healthy millennials to the established norms and to describe hand usage patterns for millennials. Grip and lateral pinch measurements were obtained from a sample of 237 healthy millennials (ages 20-34 years). Strength scores were statistically lower that older normative data in all millennial grip strengths, with the exception of the women in the age group of 30-34 years. Specifically, this statistically significant trend was observed in all male grip strengths, as well as in women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). However, the lateral pinch data reflected was similar to the older norms with variances of 0.5-1 kg. Current data reflect statistically significant differences from the norms for all male grip measurements, as well as for women in the age group of 20-24 years (bilateral grip) and 25-29 years (right grip). No statistical significance was observed in the independent-sample t tests for the lateral pinch in men of all age groups. Statistical significance was noted for lateral pinch for female age groups for the left hand (20-24 years) and for bilateral lateral pinches (30-34 years). IV. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  16. Analysis of fatigue and tremor during sustained maximal grip contractions using Hilbert-Huang Transformation.

    Science.gov (United States)

    Li, Ke; Hogrel, Jean-Yves; Duchêne, Jacques; Hewson, David J

    2012-09-01

    The objective of this study was to evaluate muscle fatigue and tremor during a Sustained Maximal Grip Contraction (SMGC) using the Hilbert-Huang Transformation (HHT). Thirty-nine healthy subjects volunteered for the study and performed a 25-s SMGC. Fatigue parameters such as the relative force output (RFO) were calculated from the residual of SMGC after applying Empirical Mode Decomposition (EMD). Using the energy spectrum of the Intrinsic Mode Functions (IMF) obtained using HHT, isometric force tremor was identified from the 4 to 12 Hz region in IMF3 and IMF4. Data were analysed for five consecutive 5-s epochs to identify changes in fatigue and tremor over time. The HHT method was able to identify a greater resistance to fatigue in women compared to men (p≤0.05) and in non-dominant hands compared to dominant hands (p≤0.05). Consistent with the results for fatigue, women had less tremor than men (p≤0.05), while non-dominant hands trembled less than did dominant hands (p≤0.05). Higher levels of tremor were observed for non-fatigue-resistant subjects for both 10-15 s and 15-20 s epochs (p≤0.05). The HHT is an appropriate method to identify both fatigue and tremor during SMGC. It would be of interest to apply this method to the study the elderly or patients with neuromuscular disorders.

  17. The Effect of Handedness on Grip Strength in Older Adults with Intellectual Disabilities

    Science.gov (United States)

    Oppewal, Alyt; Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2013-01-01

    Grip strength is an important predictor of several health outcomes in the general older population. Grip strength assessment is feasible and reliable in older adults with intellectual disabilities (ID), which makes it a valuable measurement for application in this population. The purpose of this study was to investigate the effect of handedness on…

  18. Children with flat feet have weaker toe grip strength than those having a normal arch

    Science.gov (United States)

    Tashiro, Yuto; Fukumoto, Takahiko; Uritani, Daisuke; Matsumoto, Daisuke; Nishiguchi, Shu; Fukutani, Naoto; Adachi, Daiki; Hotta, Takayuki; Morino, Saori; Shirooka, Hidehiko; Nozaki, Yuma; Hirata, Hinako; Yamaguchi, Moe; Aoyama, Tomoki

    2015-01-01

    [Purpose] This study investigated the relationship between toe grip strength and foot posture in children. [Subjects and Methods] A total of 619 children participated in this study. The foot posture of the participants was measured using a foot printer and toe grip strength was measured using a toe grip dynamometer. Children were classified into 3 groups; flatfoot, normal, and high arch, according to Staheli’s arch index. The differences in demographic data and toe grip strength among each foot posture group were analyzed by analysis of variance. Additionally, toe grip strength differences were analyzed by analysis of covariance, adjusted to body mass index, age, and gender. [Results] The number of participants classified as flatfoot, normal, and high arch were 110 (17.8%), 468 (75.6%), and 41 (6.6%), respectively. The toe grip strength of flatfoot children was significantly lower than in normal children, as shown by both analysis of variance and analysis of covariance. [Conclusion] A significant difference was detected in toe grip strength between the low arch and normal foot groups. Therefore, it is suggested that training to increase toe grip strength during childhood may prevent the formation of flat feet or help in the development of arch. PMID:26696732

  19. Getting a Grip on Numbers: Numerical Magnitude Priming in Object Grasping

    Science.gov (United States)

    Lindemann, Oliver; Abolafia, Juan M.; Girardi, Giovanna; Bekkering, Harold

    2007-01-01

    To investigate the functional connection between numerical cognition and action planning, the authors required participants to perform different grasping responses depending on the parity status of Arabic digits. The results show that precision grip actions were initiated faster in response to small numbers, whereas power grips were initiated…

  20. 16 CFR Figure 5 to Part 1512 - Typical Handbrake Actuator Showing Grip Dimension

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Typical Handbrake Actuator Showing Grip Dimension 5 Figure 5 to Part 1512 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS... Actuator Showing Grip Dimension EC03OC91.072 ...

  1. PULSE AMPLITUDE DISTRIBUTION RECORDER

    Science.gov (United States)

    Cowper, G.

    1958-08-12

    A device is described for automatica1ly recording pulse annplitude distribution received from a counter. The novelty of the device consists of the over-all arrangement of conventional circuit elements to provide an easy to read permanent record of the pulse amplitude distribution during a certain time period. In the device a pulse analyzer separates the pulses according to annplitude into several channels. A scaler in each channel counts the pulses and operates a pen marker positioned over a drivable recorder sheet. Since the scalers in each channel have the sanne capacity, the control circuitry permits counting of the incoming pulses until one scaler reaches capacity, whereupon the input is removed and an internal oscillator supplies the necessary pulses to fill up the other scalers. Movement of the chart sheet is initiated wben the first scaler reaches capacity to thereby give a series of marks at spacings proportional to the time required to fill the remaining scalers, and accessory equipment marks calibration points on the recorder sheet to facilitate direct reading of the number of external pulses supplied to each scaler.

  2. Comparison of Infant Car Seat grip orientations and lift strategies.

    Science.gov (United States)

    Clamann, Michael; Zhu, Biwen; Beaver, Leah; Taylor, Kinley; Kaber, David

    2012-07-01

    The rear-facing Infant Car Seat (ICS) is designed to meet federal requirements for transporting children less than 1 year old. Typical use includes transfer in and out of a vehicle, which is shown to be a difficult lift. Despite the frequency of this lift, manufacturers provide little guidance for users. Review of relevant literature suggested an ICS featuring an angled handle, promoting a neutral wrist posture, would increase grip stability and decrease lifting effort. Popular press suggested a foot-in-car stance for the ICS lift would do the same. An experiment was conducted in which wrist deviations from neutral posture were recorded along with lifting muscle activation levels (multiple flexor muscles and biceps brachii) and overall perceived exertion for straight versus a new bent handle design and conventional stance versus foot-in-car. Foot position was examined to test the recommendations in the popular press. Surprisingly, wrist deviation was not significantly affected by the new bent handle design (due to compensatory behavior with the straight handle) but was related to foot placement (p=0.04). Results revealed the bent handle to significantly reduce flexor activation compared with the straight handle (p=0.0003); however, the level of biceps activation increased. Biceps activation also significantly increased for foot-in-car stance (p=0.035) but not flexor activation. In general, the bent handle enabled the user to lift the ICS with a steadier grip and less effort. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. CHY formula and MHV amplitudes

    CERN Document Server

    Du, Yi-jian; Wu, Yong-shi

    2016-01-01

    In this paper, we study the relation between the Cachazo-He-Yuan (CHY) formula and the maximal-helicity-violating (MHV) amplitudes of Yang-Mills and gravity in four dimensions. We prove that only one special rational solution of the scattering equations found by Weinzierl support the MHV amplitudes. Namely, localized at this solution, the integrated CHY formula reproduces the Parke-Taylor formula for Yang-Mills amplitudes as well as the Hodges formula for gravitational amplitudes. This is achieved by developing techniques, in a manifestly M\\"obius covariant formalism, to explicitly compute relevant reduced Pfaffians/determinants. We observe and prove two interesting properties (or identities), which facilitate the computations. We also check that all the other $(n-3)!-1$ solutions to the scattering equations do not support the MHV amplitudes, and prove analytically that this is indeed true for the other special rational solution proposed by Weinzierl, that actually supports the anti-MHV amplitudes.

  4. Effects of kinesio tape compared with non-elastic tape on hand grip strength.

    Science.gov (United States)

    Kim, Ji Young; Kim, Seong Yeol

    2016-05-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm.

  5. Effects of kinesio tape compared with non-elastic tape on hand grip strength

    Science.gov (United States)

    Kim, Ji Young; Kim, Seong Yeol

    2016-01-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm. PMID:27313372

  6. Bite force and state of dentition.

    Science.gov (United States)

    Helkimo, E; Carlsson, G E; Helkimo, M

    1977-01-01

    The maximal bite force and the strength of the finger-thumb grip of 125 Skolt Lapps, aged 15 to 65, was measured with a specially devised apparatus. The bite force was measured with the biting fork placed between the first molars and between the incisors, respectively. The finger-thumb grip was measured by letting the subject press the prongs of the fork between the thumb and forefinger of each hand as hard as possible. The range of inter-individual variation of the maximal bite force and finger-thumb grip was great. The mean values were higher for the males than for the females. In the males the maximal bite force thus measured in the molar region was 39 kg (382 N) and 18 kg (176 N) in the incisor region. The corresponding values for the females were 22 kg (216 N) and 11 kg (108 N). The finger-thumb grip strength for males was, on the average, 10 kg (98 N); that of the females, 7 KG (69 N). The average difference in bite force between the men and the women was larger in the group with natural teeth than in the one with complete dentures. The values found for the bite force decreased with increasing age, especially for the females. Most of this reduction with increasing age was probably due to the age-dependent deterioration of the dentition. In both sexes the bite force was notably smaller among the denture wearers than among the dentate persons. The number of natural teeth varied closely with the bite force, i.e. the greater number of natural teeth the greater the bite force.

  7. Hand-grip strength cut points to screen older persons at risk for mobility limitation.

    Science.gov (United States)

    Sallinen, Janne; Stenholm, Sari; Rantanen, Taina; Heliövaara, Markku; Sainio, Päivi; Koskinen, Seppo

    2010-09-01

    To determine optimal hand-grip strength cut points for likelihood of mobility limitation in older people and to study whether these cut points differ according to body mass index (BMI). Cross-sectional analysis of data. Data collected in the Finnish population-based Health 2000 Survey. One thousand eighty-four men and 1,562 women aged 55 and older with complete data on anthropometry, hand-grip strength and self-reported mobility. Mobility limitation was defined as difficulty walking 0.5 km or climbing stairs. Receiver operating characteristic analysis was used to estimate hand-grip strength cut points for likelihood of mobility limitation. The overall hand-grip strength cut points for likelihood of mobility limitation were 37 kg (sensitivity 62%; specificity 76%) for men and 21 kg (sensitivity 67%; specificity 73%) for women. The effect of the interaction between hand-grip strength and BMI on mobility limitation was significant in men (P=.02), but no such interaction was observed in women (P=.16). In men, the most-optimal cutoff points were 33 kg (sensitivity 73%; specificity 79%) for normal-weight men, 39 kg (sensitivity 67%; specificity 71%) for overweight men, and 40 kg (sensitivity 57%; specificity 68%) for obese men. In women, BMI-specific hand-grip strength cutoff values was not markedly more accurate than the overall cutoff value. The hand-grip strength test is a useful tool to identify persons at risk of mobility limitation. In men, hand-grip strength cut points for mobility increased with BMI, whereas in women, only one hand-grip strength threshold was identified. © 2010, Copyright the Authors. Journal compilation © 2010, The American Geriatrics Society.

  8. Immediate and Delayed Effects of Forearm Kinesio Taping on Grip Strength

    Science.gov (United States)

    Kouhzad Mohammadi, Hosein; Khademi Kalantari, Khosro; Naeimi, Sedighe Sadat; Pouretezad, Mohammad; Shokri, Esmaeil; Tafazoli, Mojdeh; Dastjerdi, Mahboobeh; Kardooni, Leila

    2014-01-01

    Background: Due to the fundamental role of gripping in most upper limb activities, grip strength promotion is a chief goal in the treatment of patients with upper limb musculoskeletal disorders. Kinesio taping is a novel and effective therapeutic technique believed to facilitate muscle contraction through stimulating mechanoreceptors and increasing the sensory feedback around the taped region. Objectives: The present study aimed to identify the best region (flexor, extensor and flexor/extensor regions) and time (immediate, 0.5, 1, 1.5, and 2 hours) of forearm Kinesio taping to obtain the maximum improvement in grip strength. Materials and Methods: In this longitudinal study, 40 healthy men and women (the mean age of 22.3 ± 2.19 years) were selected among students of Shahid Beheshti University of Medical Sciences, Tehran, Iran by simple, nonrandom sampling method. A dynamometer was used to measure grip strength immediately and every 30 minutes during the two hours after I-shaped application of tape (with 50% stretch) to the flexor, extensor, and flexor/extensor forearm muscles. Results: Grip strength was significantly increased in various muscle groups for males (P = 0.002) and females (P = 0.000) of the forearm and at different intervals for males (P = 0.000) and females (P = 0.000). Moreover, in both men and women, tape application to the extensor region provided greater grip strength compared to taping of the flexor and flexor/extensor regions (P = 0.000 for both). Furthermore, the maximum increase in grip strength were 0.5 (10.8% increase, P = 0.001) and 1.5 h (23.9% increase, P = 0.000) after taping in males and females, respectively. Conclusions: Taping the extensor region of forearm is recommended to achieve higher grip strength. Although grip strength increased at a slower pace in females than males, the final values were higher in women. PMID:25389492

  9. Amplitude dependent closest tune approach

    CERN Document Server

    Tomas Garcia, Rogelio; Franchi, Andrea; Maclean, Ewen Hamish; CERN. Geneva. ATS Department

    2016-01-01

    Recent observations in the LHC point to the existence of an amplitude dependent closest tune approach. However this dynamical behavior and its underlying mechanism remain unknown. This effect is highly relevant for the LHC as an unexpectedly closest tune approach varying with amplitude modifies the frequency content of the beam and, hence, the Landau damping. Furthermore the single particle stability would also be affected by this effect as it would modify how particles with varying amplitudes approach and cross resonances. We present analytic derivations that lead to a mechanism generating an amplitude dependent closest tune approach.

  10. Graviton amplitudes from collinear limits of gauge amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Stieberger, Stephan, E-mail: stephan.stieberger@mpp.mpg.de [Max-Planck-Institut für Physik, Werner-Heisenberg-Institut, 80805 München (Germany); Taylor, Tomasz R. [Department of Physics, Northeastern University, Boston, MA 02115 (United States)

    2015-05-11

    We express all tree-level graviton amplitudes in Einstein's gravity as the collinear limits of a linear combination of pure Yang–Mills amplitudes in which each graviton is represented by two gauge bosons, each of them carrying exactly one half of graviton's momentum and helicity.

  11. On the Period-Amplitude and Amplitude-Period Relationships

    Science.gov (United States)

    Wilson, Robert M.; Hathaway, David H.

    2008-01-01

    Examined are Period-Amplitude and Amplitude-Period relationships based on the cyclic behavior of the 12-month moving averages of monthly mean sunspot numbers for cycles 0.23, both in terms of Fisher's exact tests for 2x2 contingency tables and linear regression analyses. Concerning the Period-Amplitude relationship (same cycle), because cycle 23's maximum amplitude is known to be 120.8, the inferred regressions (90-percent prediction intervals) suggest that its period will be 131 +/- 24 months (using all cycles) or 131 +/- 18 months (ignoring cycles 2 and 4, which have the extremes of period, 108 and 164 months, respectively). Because cycle 23 has already persisted for 142 months (May 1996 through February 2008), based on the latter prediction, it should end before September 2008. Concerning the Amplitude-Period relationship (following cycle maximum amplitude versus preceding cycle period), because cycle 23's period is known to be at least 142 months, the inferred regressions (90-percent prediction intervals) suggest that cycle 24's maximum amplitude will be about less than or equal to 96.1 +/- 55.0 (using all cycle pairs) or less than or equal to 91.0 +/- 36.7 (ignoring statistical outlier cycle pairs). Hence, cycle 24's maximum amplitude is expected to be less than 151, perhaps even less than 128, unless cycle pair 23/24 proves to be a statistical outlier.

  12. JPL Genesis and Rapid Intensification Processes (GRIP) Portal

    Science.gov (United States)

    Knosp, Brian W.; Li, P. Peggy; Vu, Quoc A.; Turk, Francis J.; Shen, Tsae-Pyng J.; Hristova-Veleva, Svetla M.; Licata, Stephen J.; Poulsen, William L.

    2012-01-01

    Satellite observations can play a very important role in airborne field campaigns, since they provide a comprehensive description of the environment that is essential for the experiment design, flight planning, and post-experiment scientific data analysis. In the past, it has been difficult to fully utilize data from multiple NASA satellites due to the large data volume, the complexity of accessing NASA s data in near-real-time (NRT), as well as the lack of software tools to interact with multi-sensor information. The JPL GRIP Portal is a Web portal that serves a comprehensive set of NRT observation data sets from NASA and NOAA satellites describing the atmospheric and oceanic environments related to the genesis and intensification of the tropical storms in the North Atlantic Ocean. Together with the model forecast data from four major global atmospheric models, this portal provides a useful tool for the scientists and forecasters in planning and monitoring the NASA GRIP field campaign during the 2010 Atlantic Ocean hurricane season. This portal uses the Google Earth plug-in to visualize various types of data sets, such as 2D maps, wind vectors, streamlines, 3D data sets presented at series of vertical cross-sections or pointwise vertical profiles, and hurricane best tracks and forecast tracks. Additionally, it allows users to overlap multiple data sets, change the opacity of each image layer, generate animations on the fly with selected data sets, and compare the observation data with the model forecast using two independent calendars. The portal also provides the capability to identify the geographic location of any point of interest. In addition to supporting the airborne mission planning, the NRT data and portal will serve as a very rich source of information during the post-field campaign analysis stage of the airborne experiment. By including a diverse set of satellite observations and model forecasts, it provides a good spatial and temporal context for the

  13. Large amplitude oscillatory elongation flow

    DEFF Research Database (Denmark)

    Rasmussen, Henrik K.; Laillé, Philippe; Yu, Kaijia

    2008-01-01

    A filament stretching rheometer (FSR) was used for measuring the elongation flow with a large amplitude oscillative elongation imposed upon the flow. The large amplitude oscillation imposed upon the elongational flow as a function of the time t was defined as epsilon(t) =(epsilon) over dot(0)t + ...

  14. Self-Biased-SMA Drive PU Microgripper with Force Sensing in Visual Servo

    Directory of Open Access Journals (Sweden)

    Ren-Jung Chang

    2013-06-01

    Full Text Available An innovative design of a polyurethane microgripper system with force sensor is developed for the measurement of gripping force in vision-based control. A microgripper mechanism integrated with a force sensing arm is fabricated by an excimer laser. The microgripper is actuated by a self-biased-SMA (Shape Memory Alloy actuator. A computer-vision method through the ERES (Extended Regional Edge Statistics algorithm is employed to track the motion of gripper. The position information of the gripping point together with the deflection of the force sensing arm is utilized for sensing force. A fuzzy expert with a PI controller in a visual servo is employed to test the performance of sensing the gripping force in grasping of 38μm diameter metal rod. In the performance test, the microgripper system provides a maximum gripping size of 40μm, a maximum force resolution of 1μN and a maximum gripping force of 58μN.

  15. Closed string amplitudes as single-valued open string amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Stieberger, Stephan, E-mail: stephan.stieberger@mpp.mpg.de [Max-Planck-Institut für Physik, Werner-Heisenberg-Institut, 80805 München (Germany); Taylor, Tomasz R. [Department of Physics, Northeastern University, Boston, MA 02115 (United States)

    2014-04-15

    We show that the single trace heterotic N-point tree-level gauge amplitude A{sub N}{sup HET} can be obtained from the corresponding type I amplitude A{sub N}{sup I} by the single-valued (sv) projection: A{sub N}{sup HET}=sv(A{sub N}{sup I}). This projection maps multiple zeta values to single-valued multiple zeta values. The latter represent a subclass of multiple zeta values originating from single-valued multiple polylogarithms at unity. Similar relations between open and closed string amplitudes or amplitudes of different string vacua can be established. As a consequence the α{sup ′}-expansion of a closed string amplitude is dictated by that of the corresponding open string amplitude. The combination of single-valued projections, Kawai–Lewellen–Tye relations and Mellin correspondence reveal a unity of all tree-level open and closed superstring amplitudes together with the maximally supersymmetric Yang–Mills and supergravity theories.

  16. Quantitative laryngeal electromyography: turns and amplitude analysis.

    Science.gov (United States)

    Statham, Melissa McCarty; Rosen, Clark A; Nandedkar, Sanjeev D; Munin, Michael C

    2010-10-01

    Laryngeal electromyography (LEMG) is primarily a qualitative examination, with no standardized approach to interpretation. The objectives of our study were to establish quantitative norms for motor unit recruitment in controls and to compare with interference pattern analysis in patients with unilateral vocal fold paralysis (VFP). Retrospective case-control study We performed LEMG of the thyroarytenoid-lateral cricoarytenoid muscle complex (TA-LCA) in 21 controls and 16 patients with unilateral VFP. Our standardized protocol used a concentric needle electrode with subjects performing variable force TA-LCA contraction. To quantify the interference pattern density, we measured turns and mean amplitude per turn for ≥10 epochs (each 500 milliseconds). Logarithmic regression analysis between amplitude and turns was used to calculate slope and intercept. Standard deviation was calculated to further define the confidence interval, enabling generation of a linear-scale graphical "cloud" of activity containing ≥90% of data points for controls and patients. Median age of controls and patients was similar (50.7 vs. 48.5 years). In controls, TA-LCA amplitude with variable contraction ranged from 145-1112 μV, and regression analysis comparing mean amplitude per turn to root-mean-square amplitude demonstrated high correlation (R = 0.82). In controls performing variable contraction, median turns per second was significantly higher compared to patients (450 vs. 290, P = .002). We first present interference pattern analysis in the TA-LCA in healthy adults and patients with unilateral VFP. Our findings indicate that motor unit recruitment can be quantitatively measured within the TA-LCA. Additionally, patients with unilateral VFP had significantly reduced turns when compared with controls.

  17. lateral asymmetry ш grip strength: utility of the ten per cent rule

    African Journals Online (AJOL)

    2001-11-01

    Nov 1, 2001 ... between strengths of dominant and non-dominant hands. Such discrepancy in ... methodological approaches in evaluation of grip strength, different .... Relations between stronger hand and hand preference. Stronger hand.

  18. Effect of Putting Grip on Eye and Head Movements During the Golf Putting Stroke

    Directory of Open Access Journals (Sweden)

    George K. Hung

    2003-01-01

    Full Text Available The objective of this article is to determine the effect of three different putting grips (conventional, cross-hand, and one-handed on variations in eye and head movements during the putting stroke. Seven volunteer novice players, ranging in age from 21 to 22 years, participated in the study. During each experimental session, the subject stood on a specially designed platform covered with artificial turf and putted golf balls towards a standard golf hole. The three different types of grips were tested at two distances: 3 and 9 ft. For each condition, 20 putts were attempted. For each putt, data were recorded over a 3-s interval at a sampling rate of 100 Hz. Eye movements were recorded using a helmet-mounted eye movement monitor. Head rotation about an imaginary axis through the top of the head and its center-of-rotation was measured by means of a potentiometer mounted on a fixed frame and coupled to the helmet. Putter-head motion was measured using a linear array of infrared phototransistors embedded in the platform. The standard deviation (STD, relative to the initial level was calculated for eye and head movements over the duration of the putt (i.e., from the beginning of the backstroke, through the forward stroke, to impact. The averaged STD for the attempted putts was calculated for each subject. Then, the averaged STDs and other data for the seven subjects were statistically compared across the three grip conditions. The STD of eye movements were greater (p < 0.1 for conventional than cross-hand (9 ft and one-handed (3 and 9 ft grips. Also, the STD of head movements were greater (p < 0.1; 3 ft for conventional than cross-hand and one-handed grips. Vestibulo-ocular responses associated with head rotations could be observed in many 9 ft and some 3 ft putts. The duration of the putt was significantly longer (p < 0.05; 3 and 9 ft for the one-handed than conventional and cross-hand grips. Finally, performance, or percentage putts made, was

  19. Subharmonic and fundamental high amplitude excitation of an axisymmetric jet

    Science.gov (United States)

    Raman, Ganesh; Rice, Edward J.

    1989-01-01

    The effect of simultaneous excitation at the fundamental and subharmonic frequencies on the behavior of a circular jet shear layer is studied. Attention is given to the effect of the initial phase difference, the Strouhal number pair, and amplitudes of the fundamental and subharmonic tones. High-amplitude excitation devices which can provide a wide range of forcing conditions when used in conjunction with equipment that produces complex waveforms are used.

  20. Improvement of handle grip using reverse engineering, CAE and Rapid Prototyping

    Directory of Open Access Journals (Sweden)

    Stoklasek Pavel

    2016-01-01

    Full Text Available The overwhelming majority of manual operations is even nowadays performed by using manual hand tools. These tools can be divided into 2 groups – hand tools designed for general use or a single-purpose hand tools for special operations. Tool described in this paper is used in assembling operation in the completion of electric motor. During the design of the existing tools the requirements for a functional part of the tool (lifespan, inability to damage the engine installation were fully considered, demands for ergonomic grip area, however, were not taken into account. Long-term use of incorrectly designed tool causes carpal tunnel syndrome, hand-arm vibration syndrome, diminished sensitivity or tingling in the fingers of workers. These difficulties can be reduced or entirely eliminated due to proper design of the grip of hand tool. Most authors focus on adjusting the grip for optimum ergonomics at individual types of grips (cylindrical, palmar, lateral, etc.. However, as already mentioned, there are tools for specific operations when the working area is limited by space or a specific type of load on the grip is needed. In some cases, it is often necessary to change the type of grip or combine different types of grips. This paper describes the design of an optimal grip of hand tool used for specific operation when assembling motors. Design of prototype mold and production of functional prototypes for ergonomics assessment directly in the workplace were realized. New design of handle should reduce the risk primarily of developing carpal tunnel in long-term use.

  1. Optimization of phase contrast in bimodal amplitude modulation AFM

    Directory of Open Access Journals (Sweden)

    Mehrnoosh Damircheli

    2015-04-01

    Full Text Available Bimodal force microscopy has expanded the capabilities of atomic force microscopy (AFM by providing high spatial resolution images, compositional contrast and quantitative mapping of material properties without compromising the data acquisition speed. In the first bimodal AFM configuration, an amplitude feedback loop keeps constant the amplitude of the first mode while the observables of the second mode have not feedback restrictions (bimodal AM. Here we study the conditions to enhance the compositional contrast in bimodal AM while imaging heterogeneous materials. The contrast has a maximum by decreasing the amplitude of the second mode. We demonstrate that the roles of the excited modes are asymmetric. The operational range of bimodal AM is maximized when the second mode is free to follow changes in the force. We also study the contrast in trimodal AFM by analyzing the kinetic energy ratios. The phase contrast improves by decreasing the energy of second mode relative to those of the first and third modes.

  2. Optimization of phase contrast in bimodal amplitude modulation AFM.

    Science.gov (United States)

    Damircheli, Mehrnoosh; Payam, Amir F; Garcia, Ricardo

    2015-01-01

    Bimodal force microscopy has expanded the capabilities of atomic force microscopy (AFM) by providing high spatial resolution images, compositional contrast and quantitative mapping of material properties without compromising the data acquisition speed. In the first bimodal AFM configuration, an amplitude feedback loop keeps constant the amplitude of the first mode while the observables of the second mode have not feedback restrictions (bimodal AM). Here we study the conditions to enhance the compositional contrast in bimodal AM while imaging heterogeneous materials. The contrast has a maximum by decreasing the amplitude of the second mode. We demonstrate that the roles of the excited modes are asymmetric. The operational range of bimodal AM is maximized when the second mode is free to follow changes in the force. We also study the contrast in trimodal AFM by analyzing the kinetic energy ratios. The phase contrast improves by decreasing the energy of second mode relative to those of the first and third modes.

  3. PICK1 interacts with ABP/GRIP to regulate AMPA receptor trafficking.

    Science.gov (United States)

    Lu, Wei; Ziff, Edward B

    2005-08-04

    PICK1 and ABP/GRIP bind to the AMPA receptor (AMPAR) GluR2 subunit C terminus. Transfer of the receptor from ABP/GRIP to PICK1, facilitated by GluR2 S880 phosphorylation, may initiate receptor trafficking. Here we report protein interactions that regulate these steps. The PICK1 BAR domain interacts intermolecularly with the ABP/GRIP linker II region and intramolecularly with the PICK1 PDZ domain. Binding of PKCalpha or GluR2 to the PICK1 PDZ domain disrupts the intramolecular interaction and facilitates the PICK1 BAR domain association with ABP/GRIP. Interference with the PICK1-ABP/GRIP interaction impairs S880 phosphorylation of GluR2 by PKC and decreases the constitutive surface expression of GluR2, the NMDA-induced endocytosis of GluR2, and recycling of internalized GluR2. We suggest that the PICK1 interaction with ABP/GRIP is a critical step in controlling GluR2 trafficking.

  4. Adductor pollicis muscle and hand grip strength: potential methods of nutritional assessment in outpatients with stroke

    Directory of Open Access Journals (Sweden)

    Débora Rocha Oliveira

    2010-12-01

    Full Text Available Objective: To evaluate and compare the effectiveness of different methods used for nutritional assessment of outpatients who had hemiplegic stroke. Methods: A cross-section study with adult and elderly patients of both genders enrolled in a rehabilitation center. The analyzed variables were anthropometric measurements, bioelectrical impedance, hand grip strength and thickness of the adductor pollicis muscle. The Pearson χ2 test was used to check the association between variables with a significance level of α = 5%. Results: When evaluating the association between indicators of muscle mass, it was observed that the hand grip strength in both genders was positively correlated with arm muscle circumference (p = 0.0196 and lean mass (p = 0.0002. Fat mass measured by the bioelectrical impedance method already showed a significant inverse relationship with the grip (r = -0.3879. The thickness of the adductor pollicis muscle showed significant association with lean mass (p = 0.0052 and hand grip (p = 0.0024. Conclusion: In this study, the hand grip strength and thickness of the adductor pollicis muscle were well correlated with measurements determined by anthropometry and bioimpedance. The results show the applicability of grip strength and thickness of the adductor pollicis muscle in clinical practice as nutritional assessment methods for this population, especially elderly patients, since they detect functional changes not captured by other parameters in the short term and are important for early identification of risk nutrition.

  5. [Isometric grip strength and social gerontological research: results and analytic potentials of SHARE and SOEP].

    Science.gov (United States)

    Hank, K; Jürges, H; Schupp, J; Wagner, G G

    2009-04-01

    This paper shows that the measurement of hand grip strength provides a non-invasive and reliable objective health indicator for social science research and is easy to collect in general population surveys. Grip strength is not only a useful complement of self-reported indicators of health, but it also exhibits a considerable predictive power with regard to a number of further relevant variables for social gerontological research, such as mortality risks. New data from the 2004 Survey of Health, Ageing and Retirement in Europe (SHARE) and the 2006 wave of the German Socio-Economic Panel Study (SOEP) allow insightful methodological and very first substantive cross-sectional analyses of grip strength in Germany. The focus of the present study is on the analysis of individuals aged 50 or older. The experience of both surveys when measuring grip strength is consistently positive, particularly with regard to the respondents' feedback. Major determinants of isometric grip strength are - beyond the individual's gender - age, body size and weight. A multivariate analysis also provides evidence for a clear positive association between various health indicators and grip strength.

  6. Hold, grasp, clutch or grab: consumer grip choices during food container opening.

    Science.gov (United States)

    Rowson, J; Yoxall, A

    2011-07-01

    Society is ageing and sadly that ageing leads to a host of issues, not least a society in which the majority are likely to have some loss of strength and dexterity. This can lead to complications in undertaking everyday tasks such as using transport, bathing or even handling and opening food. Packaging has to provide a multitude of services; to protect and preserve the product, to provide information to the consumer and not least to allow access to the contents. This access to packaging--or 'openability'--has become a significant issue for designers and manufacturers with the change in demographics as described above. Understanding the choices consumers make in how they manipulate packaging can help designers produce packaging that is more able to meet the requirements of modern society. Studies previously undertaken by the authors showed that consumers did use different grips when opening packaging and that certain grips were theoretically more comfortable and stronger than others. This paper outlines a further study whereby consumers were asked to apply the most common grips to a specially designed torque measuring device. Details were taken about the consumers: age, gender, occupation, hand size, plus their preferred grip choice for packaging of this type. The study showed that typically women chose a grip that maximised their opportunity of opening the closure and that this grip choice was more limited than that available for men. This has implications for inclusive design of many everyday products.

  7. Grip strength measurements at two different wrist extension positions in chronic lateral epicondylitis-comparison of involved vs. uninvolved side in athletes and non athletes: a case-control study

    Directory of Open Access Journals (Sweden)

    Bhargava Arti S

    2010-09-01

    Full Text Available Abstract Background Lateral epicondylitis is a common sports injury of the elbow caused due to altered muscle activation during repetitive wrist extension in many athletic and non-athletic endeavours. The amount of muscle activity and timing of contraction eventually is directly dependent upon joint position during the activity. The purpose of our study was to compare the grip strength in athletes with lateral epicondylalgia in two different wrist extension positions and compare them between involved and uninvolved sides of athletes and non-athletes. Methods An assessor-blinded case-control study of eight athletes and twenty-two non-athletes was done. The grip strength was measured using JAMAR® hand dynamometer in kilograms-force at 15 degrees (slightly extended and 35 degrees (moderately extended wrist extension positions (maintained by wrist splints on both involved and uninvolved sides of athletes and non-athletes with unilateral lateral epicondylitis of atleast 3 months duration. Their pain was to be elicited with local tenderness and two of three tests being positive- Cozen's, Mill's manoeuvre, resisted middle finger extension tests. For comparisons of grip strength, Wilcoxon signed rank test was used for within-group comparison (between 15 and 35 degrees wrist extension positions and Mann-Whitney U test was used for between-group (athletes vs. non-athletes comparisons at 95% confidence interval and were done using SPSS 11.5 for Windows. Results Statistically significant greater grip strength was found in 15 degrees (27.75 ± 4.2 kgms in athletes; 16.45 ± 4.2 kgms in non-athletes wrist extension than at 35 degrees (25.25 ± 3.53 kgm in athletes and 14.18 ± 3.53 kgm in non-athletes. The athletes had greater grip strength than non-athletes in each of test positions (11.3 kgm at 15 degrees and 11.07 kgm at 35 degrees measured. There was also a significant difference between involved and uninvolved sides' grip strength at both wrist

  8. WITHDRAWN: Positive force feedback in development of substrate grip in the stick insect tarsus.

    Science.gov (United States)

    Zill, Sasha N; Chaudhry, Sumaiya; Exter, Annelie; Büschges, Ansgar; Schmitz, Josef

    2014-06-04

    The Publisher regrets that this article is an accidental duplication of an article that has already been published, http://dx.doi.org/10.1016/j.asd.2014.06.002. The duplicate article has therefore been withdrawn.

  9. Scattering amplitudes in gauge theories

    CERN Document Server

    Henn, Johannes M

    2014-01-01

    At the fundamental level, the interactions of elementary particles are described by quantum gauge field theory. The quantitative implications of these interactions are captured by scattering amplitudes, traditionally computed using Feynman diagrams. In the past decade tremendous progress has been made in our understanding of and computational abilities with regard to scattering amplitudes in gauge theories, going beyond the traditional textbook approach. These advances build upon on-shell methods that focus on the analytic structure of the amplitudes, as well as on their recently discovered hidden symmetries. In fact, when expressed in suitable variables the amplitudes are much simpler than anticipated and hidden patterns emerge.   These modern methods are of increasing importance in phenomenological applications arising from the need for high-precision predictions for the experiments carried out at the Large Hadron Collider, as well as in foundational mathematical physics studies on the S-matrix in quantum ...

  10. Positive Amplitudes In The Amplituhedron

    CERN Document Server

    Arkani-Hamed, Nima; Trnka, Jaroslav

    2014-01-01

    The all-loop integrand for scattering amplitudes in planar N = 4 SYM is determined by an "amplitude form" with logarithmic singularities on the boundary of the amplituhedron. In this note we provide strong evidence for a new striking property of the superamplitude, which we conjecture to be true to all loop orders: the amplitude form is positive when evaluated inside the amplituhedron. The statement is sensibly formulated thanks to the natural "bosonization" of the superamplitude associated with the amplituhedron geometry. However this positivity is not manifest in any of the current approaches to scattering amplitudes, and in particular not in the cellulations of the amplituhedron related to on-shell diagrams and the positive grassmannian. The surprising positivity of the form suggests the existence of a "dual amplituhedron" formulation where this feature would be made obvious. We also suggest that the positivity is associated with an extended picture of amplituhedron geometry, with the amplituhedron sitting...

  11. Model selection for amplitude analysis

    CERN Document Server

    Guegan, Baptiste; Stevens, Justin; Williams, Mike

    2015-01-01

    Model complexity in amplitude analyses is often a priori under-constrained since the underlying theory permits a large number of amplitudes to contribute to most physical processes. The use of an overly complex model results in reduced predictive power and worse resolution on unknown parameters of interest. Therefore, it is common to reduce the complexity by removing from consideration some subset of the allowed amplitudes. This paper studies a data-driven method for limiting model complexity through regularization during regression in the context of a multivariate (Dalitz-plot) analysis. The regularization technique applied greatly improves the performance. A method is also proposed for obtaining the significance of a resonance in a multivariate amplitude analysis.

  12. Posture, Flexibility and Grip Strength in Horse Riders

    Directory of Open Access Journals (Sweden)

    Hobbs Sarah Jane

    2014-10-01

    Full Text Available Since the ability to train the horse to be ambidextrous is considered highly desirable, rider asymmetry is recognized as a negative trait. Acquired postural and functional asymmetry can originate from numerous anatomical regions, so it is difficult to suggest if any is developed due to riding. The aim of this study was therefore to assess symmetry of posture, strength and flexibility in a large population of riders and to determine whether typical traits exist due to riding. 127 right handed riders from the UK and USA were categorized according to years riding (in 20 year increments and their competition level (using affiliated test levels. Leg length, grip strength and spinal posture were measured and recorded by a physiotherapist. Standing and sitting posture and trunk flexibility were measured with 3-D motion capture technology. Right-left differences were explored in relation to years riding and rider competitive experience. Significant anatomical asymmetry was found for the difference in standing acromion process height for a competition level (-0.07±1.50 cm Intro/Prelim; 0.02±1.31 cm Novice; 0.43±1.27 cm Elementary+; p=0.048 and for sitting iliac crest height for years riding (-0.23±1.36 cm Intro/Prelim; 0.01±1.50 cm Novice; 0.86±0.41 cm Elementary+; p=0.021. For functional asymmetry, a significant interaction was found for lateral bending ROM for years riding x competition level (p=0.047. The demands on dressage riders competing at higher levels may predispose these riders to a higher risk of developing asymmetry and potentially chronic back pain rather than improving their symmetry

  13. Genetic influences on the development of grip strength in adolescence.

    Science.gov (United States)

    Isen, Joshua; McGue, Matt; Iacono, William

    2014-06-01

    Enhanced physical strength is a secondary sex characteristic in males. Sexual dimorphism in physical strength far exceeds sex differences in stature or total body mass, suggesting a legacy of intense sexual selection. Upper-body strength is a particularly promising marker of intrasexual competitiveness in young men. Consequently, it is assumed that sex-influenced gene expression contributes to the development of physical strength. It is unclear, however, whether the underlying sources of individual differences in strength development are comparable across sex. We obtained three measurements of hand-grip strength (HGS) over a six-year period spanning adolescence in male and female same-sex twins (N = 2,513). Biometrical latent growth models were used to partition the HGS variance at age 11 (intercept) and its growth over time (slope) into genetic and environmental components. Results demonstrated that variance around the intercept was highly heritable in both males and females (88% and 79%, respectively). In males, variance around the slope exceeded that of the intercept, while the reverse held for females. Additive genetic effects accounted for most (80%) of the variance around the slope in males, but were of less importance in females (heritability = 28%). Absolute genetic variance around the slope was nearly nine-fold higher in males. This striking disparity suggests that the developmental processes shaping HGS growth are different between the sexes. We propose that this might account for the sex-specific pattern of associations between HGS and external measures (e.g., digit ratio and physical aggression) typically reported in the literature. Our results underscore the role of endogenous androgenic influences in the development of physical strength.

  14. Posture, flexibility and grip strength in horse riders.

    Science.gov (United States)

    Hobbs, Sarah Jane; Baxter, Joanna; Broom, Louise; Rossell, Laura-Ann; Sinclair, Jonathan; Clayton, Hilary M

    2014-09-29

    Since the ability to train the horse to be ambidextrous is considered highly desirable, rider asymmetry is recognized as a negative trait. Acquired postural and functional asymmetry can originate from numerous anatomical regions, so it is difficult to suggest if any is developed due to riding. The aim of this study was therefore to assess symmetry of posture, strength and flexibility in a large population of riders and to determine whether typical traits exist due to riding. 127 right handed riders from the UK and USA were categorized according to years riding (in 20 year increments) and their competition level (using affiliated test levels). Leg length, grip strength and spinal posture were measured and recorded by a physiotherapist. Standing and sitting posture and trunk flexibility were measured with 3-D motion capture technology. Right-left differences were explored in relation to years riding and rider competitive experience. Significant anatomical asymmetry was found for the difference in standing acromion process height for a competition level (-0.07±1.50 cm Intro/Prelim; 0.02±1.31 cm Novice; 0.43±1.27 cm Elementary+; p=0.048) and for sitting iliac crest height for years riding (-0.23±1.36 cm Intro/Prelim; 0.01±1.50 cm Novice; 0.86±0.41 cm Elementary+; p=0.021). For functional asymmetry, a significant interaction was found for lateral bending ROM for years riding x competition level (p=0.047). The demands on dressage riders competing at higher levels may predispose these riders to a higher risk of developing asymmetry and potentially chronic back pain rather than improving their symmetry.

  15. Normative Measurements of Grip and Pinch Strengths of 21st Century Korean Population

    Directory of Open Access Journals (Sweden)

    Jin Hee Shim

    2013-01-01

    Full Text Available BackgroundMeasuring grip and pinch strength is an important part of hand injury evaluation. Currently, there are no standardized values of normal grip and pinch strength among the Korean population, and lack of such data prevents objective evaluation of post-surgical recovery in strength. This study was designed to establish the normal values of grip and pinch strength among the healthy Korean population and to identify any dependent variables affecting grip and pinch strength.MethodsA cross-sectional study was carried out. The inclusion criterion was being a healthy Korean person without a previous history of hand trauma. The grip strength was measured using a Jamar dynamometer. Pulp and key pinch strength were measured with a hydraulic pinch gauge. Intra-individual and inter-individual variations in these variables were analyzed in a standardized statistical manner.ResultsThere were a total of 336 healthy participants between 13 and 77 years of age. As would be expected in any given population, the mean grip and pinch strength was greater in the right hand than the left. Male participants (137 showed mean strengths greater than female participants (199 when adjusted for age. Among the male participants, anthropometric variables correlated positively with grip strength, but no such correlations were identifiable in female participants in a statistically significant way.ConclusionsObjective measurements of hand strength are an important component of hand injury evaluation, and population-specific normative data are essential for clinical and research purposes. This study reports updated normative hand strengths of the South Korean population in the 21st century.

  16. Efeito da preensão manual sobre o equilíbrio de judocas Effect of hand grip on the balance of judokas

    Directory of Open Access Journals (Sweden)

    Jonathan Ache Dias

    2011-06-01

    Full Text Available O objetivo deste estudo foi verificar se existe efeito da preensão manual máxima (o ato de realizar ou não a preensão sobre o controle do equilíbrio de judocas em postura restrita, além de verificar se existe correlação entre a força de preensão manual (FPM e o controle do equilíbrio. Foram avaliados sete judocas com um dinamômetro e uma plataforma estabilométrica sendo mensuradas, concomitantemente, a FPM e o centro de pressão (CP. Foi verificado que até 80% da variabilidade do CP pode ser atrelada a preensão manual indicando que a mesma gera perturbações no controle do equilíbrio. Entretanto, foram encontradas correlações (r = 0,348 até 0,816 entre a FPM e o deslocamento do CP. Com isso pode-se concluir que, apesar da preensão manual gerar perturbações no equilíbrio, seu comportamento parece estar relacionado com os movimentos do corpo realizados para manter o equilíbrio, indicando uma possível correlação entre esses fenômenos.The purpose of this study was to verify if there is an effect of maximum hand grip (the act of performing or not the hand grip on the balance control of judokas in a restrict posture, and also to verify if there is a correlation between the hand grip strength (HGS and the balance control. Seven judokas were evaluated with a dynamometer and a stabilometric force platform, being measured, at the same time, the HGS and the center of pressure (COP. It was found that up to 80% of the COP variability was related to the hand grip demonstrating that it generates perturbations to the balance control. However, It was found correlations (r = 0,348 to 0,816 between de HGS and de COP displacement. With that, it can be concluded that, despite the hand grip generating perturbation on the balance, its behavior appears to be related to the body movements performed to sustain balance, indicating a possible correlation between this phenomenons.

  17. ANALYSIS ON THE SPINNING FORCES IN FLEXIBLE SPINNING OF CONES

    Institute of Scientific and Technical Information of China (English)

    Xia Qinxiang; Susumu Shima

    2003-01-01

    Flexible spinning is a new type of spinning process where spin-forming is performed without using a mandrel. Combining shearing and rolling processes, the calculation formulas of thespinning forces in flexible spinning of cones is presented. The effects of the main processing parameters, such as gripping force G applied to the blank by the inner roller, the feed rate of rollersfand the roundness radius of outer roller ro, on the spinning forces are analyzed experimentally and theoretically.

  18. Computing Maximally Supersymmetric Scattering Amplitudes

    Science.gov (United States)

    Stankowicz, James Michael, Jr.

    This dissertation reviews work in computing N = 4 super-Yang--Mills (sYM) and N = 8 maximally supersymmetric gravity (mSUGRA) scattering amplitudes in D = 4 spacetime dimensions in novel ways. After a brief introduction and overview in Ch. 1, the various techniques used to construct amplitudes in the remainder of the dissertation are discussed in Ch. 2. This includes several new concepts such as d log and pure integrand bases, as well as how to construct the amplitude using exactly one kinematic point where it vanishes. Also included in this chapter is an outline of the Mathematica package on shell diagrams and numerics.m (osdn) that was developed for the computations herein. The rest of the dissertation is devoted to explicit examples. In Ch. 3, the starting point is tree-level sYM amplitudes that have integral representations with residues that obey amplitude relations. These residues are shown to have corresponding residue numerators that allow a double copy prescription that results in mSUGRA residues. In Ch. 4, the two-loop four-point sYM amplitude is constructed in several ways, showcasing many of the techniques of Ch. 2; this includes an example of how to use osdn. The two-loop five-point amplitude is also presented in a pure integrand representation with comments on how it was constructed from one homogeneous cut of the amplitude. On-going work on the two-loop n-point amplitude is presented at the end of Ch. 4. In Ch. 5, the three-loop four-point amplitude is presented in the d log representation and in the pure integrand representation. In Ch. 6, there are several examples of four- through seven-loop planar diagrams that illustrate how considerations of the singularity structure of the amplitude underpin dual-conformal invariance. Taken with the previous examples, this is additional evidence that the structure known to exist in the planar sector extends to the full theory. At the end of this chapter is a proof that all mSUGRA amplitudes have a pole at

  19. ADJUSTMENT ERRORS IN ASCENDING AND DESCENDING PHASES OF TARGET LEVEL IN CONTROLLED FORCE EXERTION.

    Science.gov (United States)

    Kubota, Hiroshi; Demura, Shinichi

    2015-10-01

    Hand grip force adjustment errors to ascending and descending phases of a sinusoidal target force in a controlled force exertion (CFE) test were measured and the laterality of responses evaluated. 75 men (M age = 19.6 yr., SD = 1.6) performed the CFE test after one practice trial by matching handgrip force to target level (5-25% of maximal grip force). The CFE errors in ascending and descending phases of the target force were calculated as the absolute differences between actual force and target force in each phase. There were significantly smaller CFE errors in the ascending phase for both dominant and non-dominant hands, but CFE error for the dominant hand was significantly smaller in both phases. Therefore, error in force exertion in the ascending and descending phases of the target force differed, and laterality influenced error in both phases.

  20. Scattering Amplitudes in Gauge Theories

    CERN Document Server

    Schubert, Ulrich

    2014-01-01

    This thesis is focused on the development of new mathematical methods for computing multi-loop scattering amplitudes in gauge theories. In this work we combine, for the first time, the unitarity-based construction for integrands, and the recently introduced integrand-reduction through multivariate polynomial division. After discussing the generic features of this novel reduction algorithm, we will apply it to the one- and two-loop five-point amplitudes in ${\\cal N}=4$ sYM. The integrands of the multiple-cuts are generated from products of tree-level amplitudes within the super-amplitudes formalism. The corresponding expressions will be used for the analytic reconstruction of the polynomial residues. Their parametric form is known a priori, as derived by means of successive polynomial divisions using the Gr\\"obner basis associated to the on-shell denominators. The integrand reduction method will be exploited to investigate the color-kinematic duality for multi-loop ${\\cal N}=4$ sYM scattering amplitudes. Our a...

  1. Muscle-Pair Specific Distribution and Grip-Type Modulation of Neural Common Input to Extrinsic Digit Flexors

    Science.gov (United States)

    Winges, Sara A.; Johnston, Jamie A.; Santello, Marco

    2007-01-01

    To gain insight into the synergistic control of hand muscles, we have recently quantified the strength of correlated neural activity across motor units from extrinsic digit flexors during a five-digit object-hold task. We found stronger synchrony and coherence across motor units from thumb and index finger flexor muscle compartment than between the thumb flexor and other finger flexor muscle compartments. The present study of two-digit object hold was designed to determine the extent to which such distribution of common input among thumb-finger flexor muscle compartments, revealed by holding an object with five digits, is preserved when varying the functional role of a given digit pair. We recorded normal force exerted by the digits and electrical activity of single motor units from muscle flexor pollicis longus (FPL) and two compartments of the m. flexor digitorum profundus (FDP2 and FDP3; index and middle finger, respectively). Consistent with our previous results from five-digit grasping, synchrony and coherence across motor units from FPL-FDP2 was significantly stronger than in FPL-FDP3 during object hold with two digits [common input strength: 0.49 ± 0.02 and 0.35 ± 0.02 (means ± SE), respectively; peak coherence: 0.0054 and 0.0038, respectively]. This suggests that the distribution of common neural input is muscle-pair specific regardless of grip type. However, the strength of coherence, but not synchrony, was significantly stronger in two- versus five-digit object hold for both muscle combinations, suggesting the periodicity of common input is sensitive to grip type. PMID:16723414

  2. AtGRIP protein locates to the secretory vesicles of trans Golgi-network in Arabidopsis root cap cells

    Institute of Scientific and Technical Information of China (English)

    CHEN Ying; ZHANG Wei; ZHAO Lei; LI Yan

    2008-01-01

    GRIP domain proteins, locating to the trans-Golgi network, are thought to play an essential role in Golgi apparatus trafficking in yeast and animal cells. In the present study, AtGRIP cDNA was amplified by reverse transcriptase PCR from RNA isolated from Arabidopsis seedling. The GST fusion protein of AtGRIP was affinity-purified and its rabbit polyclonal antibody was obtained. Immuno-blotting with the purified anti-AtGRIP polyclonal antibody demonstrated that the molecular mass of AtGRIP protein is about 92 kD, and its expression is not tissue-specific in Arabidopsis. Immunoflourescent labeling and confocal microscopy revealed that the AtGRIP protein was co-localized with Golgi stacks in Arabidop-sis root cells. Immuno-gold labeling and electron microscopy observation showed that AtGRIP protein was mainly located to the membrane of the secretory vesicles of trans-Golgi network in Arabidopsis root cap cells. Taken together, these results indicate that the localization of GRIP domain proteins be-tween plants and animal cells are conserved. These results also suggest that the AtGRIP may be in-volved in regulating the formation or sorting of Golgi-associated vesicles in plant cells.

  3. Factorization of Chiral String Amplitudes

    CERN Document Server

    Huang, Yu-tin; Yuan, Ellis Ye

    2016-01-01

    We re-examine a closed-string model defined by altering the boundary conditions for one handedness of two-dimensional propagators in otherwise-standard string theory. We evaluate the amplitudes using Kawai-Lewellen-Tye factorization into open-string amplitudes. The only modification to standard string theory is effectively that the spacetime Minkowski metric changes overall sign in one open-string factor. This cancels all but a finite number of states: As found in earlier approaches, with enough supersymmetry (e.g., type II) the tree amplitudes reproduce those of the massless truncation of ordinary string theory. However, we now find for the other cases that additional fields, formerly thought to be auxiliary, describe new spin-2 states at the two adjacent mass levels (tachyonic and tardyonic). The tachyon is always a ghost, but can be avoided in the heterotic case.

  4. Factorization of chiral string amplitudes

    Science.gov (United States)

    Huang, Yu-tin; Siegel, Warren; Yuan, Ellis Ye

    2016-09-01

    We re-examine a closed-string model defined by altering the boundary conditions for one handedness of two-dimensional propagators in otherwise-standard string theory. We evaluate the amplitudes using Kawai-Lewellen-Tye factorization into open-string amplitudes. The only modification to standard string theory is effectively that the spacetime Minkowski metric changes overall sign in one open-string factor. This cancels all but a finite number of states: as found in earlier approaches, with enough supersymmetry (e.g., type II) the tree amplitudes reproduce those of the massless truncation of ordinary string theory. However, we now find for the other cases that additional fields, formerly thought to be auxiliary, describe new spin-2 states at the two adjacent mass levels (tachyonic and tardyonic). The tachyon is always a ghost, but can be avoided in the heterotic case.

  5. Shape of Pion Distribution Amplitude

    Energy Technology Data Exchange (ETDEWEB)

    Radyushkin, Anatoly

    2009-11-01

    A scenario is investigated in which the leading-twist pion distribution amplitude $\\varphi_\\pi (x)$ is approximated by the pion decay constant $f_\\pi$ for all essential values of the light-cone fraction $x$. A model for the light-front wave function $\\Psi (x, k_\\perp)$ is proposed that produces such a distribution amplitude and has a rapidly decreasing (exponential for definiteness) dependence on the light-front energy combination $ k_\\perp^2/x(1-x)$. It is shown that this model easily reproduces the fit of recent large-$Q^2$ BaBar data on the photon-pion transition form factor. Some aspects of scenario with flat pion distribution amplitude are discussed.

  6. Nonsinglet pentagons and NMHV amplitudes

    Directory of Open Access Journals (Sweden)

    A.V. Belitsky

    2015-07-01

    Full Text Available Scattering amplitudes in maximally supersymmetric gauge theory receive a dual description in terms of the expectation value of the super Wilson loop stretched on a null polygonal contour. This makes the analysis amenable to nonperturbative techniques. Presently, we elaborate on a refined form of the operator product expansion in terms of pentagon transitions to compute twist-two contributions to NMHV amplitudes. To start with, we provide a novel derivation of scattering matrices starting from Baxter equations for flux-tube excitations propagating on magnon background. We propose bootstrap equations obeyed by pentagon form factors with nonsinglet quantum numbers with respect to the R-symmetry group and provide solutions to them to all orders in 't Hooft coupling. These are then successfully confronted against available perturbative calculations for NMHV amplitudes to four-loop order.

  7. Proposed technique for inguinal hernia repair with self-gripping mesh: avoiding fixation to undesired structures.

    Science.gov (United States)

    Porrero, J L; Cano-Valderrama, O; Castillo, M J; Alonso, M T

    2015-10-01

    Self-gripping meshes have been developed to avoid fixing sutures during inguinal hernia repair. Operative time is shorter when using a self-gripping mesh than with conventional Lichtenstein repair. However, these meshes can be difficult to handle because they fix to undesired structures. The aim of this report is to describe a new technique to avoid this problem. Inguinal hernia dissection is made as usual. Once dissection is finished, a Parietex ProGrip(®) (Covidien, Dublin, Ireland) flat sheet mesh is cut depending on the size needed. A small split is made between the lower and medium third of the mesh to mark where the split for the spermatic cord will be. Using this mark, the upper third of the mesh is folded over the medium third, hiding the microgrips that make this a self-gripping mesh. In this way, only the lower third of the mesh has the microgrips exposed and the mesh can be fixed to the pubic bone and inguinal ligament without fixation to undesired structures. Once the lower third of the mesh is fixed, the split for the spermatic cord is completed and the upper part of the mesh is passed below the spermatic cord. Then, the mesh is unfolded to expose the microgrips again and the medium and upper third of the mesh are descended to its final position. This proposed technique for inguinal hernia repair with self-gripping mesh makes the surgery easier, avoiding mesh fixation to undesired structures.

  8. Amplitude Equation for Instabilities Driven at Deformable Surfaces - Rosensweig Instability

    Science.gov (United States)

    Pleiner, Harald; Bohlius, Stefan; Brand, Helmut R.

    2008-11-01

    The derivation of amplitude equations from basic hydro-, magneto-, or electrodynamic equations requires the knowledge of the set of adjoint linear eigenvectors. This poses a particular problem for the case of a free and deformable surface, where the adjoint boundary conditions are generally non-trivial. In addition, when the driving force acts on the system via the deformable surface, not only Fredholm's alternative in the bulk, but also the proper boundary conditions are required to get amplitude equations. This is explained and demonstrated for the normal field (or Rosensweig) instability in ferrofluids as well as in ferrogels. An important aspect of the problem is its intrinsic dynamic nature, although at the end the instability is stationary. The resulting amplitude equation contains cubic and quadratic nonlinearities as well as first and (in the gel case) second order time derivatives. Spatial variations of the amplitudes cannot be obtained by using simply Newell's method in the bulk.

  9. Estimating thumb-index finger precision grip and manipulation potential in extant and fossil primates.

    Science.gov (United States)

    Feix, Thomas; Kivell, Tracy L; Pouydebat, Emmanuelle; Dollar, Aaron M

    2015-05-06

    Primates, and particularly humans, are characterized by superior manual dexterity compared with other mammals. However, drawing the biomechanical link between hand morphology/behaviour and functional capabilities in non-human primates and fossil taxa has been challenging. We present a kinematic model of thumb-index precision grip and manipulative movement based on bony hand morphology in a broad sample of extant primates and fossil hominins. The model reveals that both joint mobility and digit proportions (scaled to hand size) are critical for determining precision grip and manipulation potential, but that having either a long thumb or great joint mobility alone does not necessarily yield high precision manipulation. The results suggest even the oldest available fossil hominins may have shared comparable precision grip manipulation with modern humans. In particular, the predicted human-like precision manipulation of Australopithecus afarensis, approximately one million years before the first stone tools, supports controversial archaeological evidence of tool-use in this taxon.

  10. Employing Helicity Amplitudes for Resummation

    CERN Document Server

    Moult, Ian; Tackmann, Frank J; Waalewijn, Wouter J

    2015-01-01

    Many state-of-the-art QCD calculations for multileg processes use helicity amplitudes as their fundamental ingredients. We construct a simple and easy-to-use helicity operator basis in soft-collinear effective theory (SCET), for which the hard Wilson coefficients from matching QCD onto SCET are directly given in terms of color-ordered helicity amplitudes. Using this basis allows one to seamlessly combine fixed-order helicity amplitudes at any order they are known with a resummation of higher-order logarithmic corrections. In particular, the virtual loop amplitudes can be employed in factorization theorems to make predictions for exclusive jet cross sections without the use of numerical subtraction schemes to handle real-virtual infrared cancellations. We also discuss matching onto SCET in renormalization schemes with helicities in $4$- and $d$-dimensions. To demonstrate that our helicity operator basis is easy to use, we provide an explicit construction of the operator basis, as well as results for the hard m...

  11. Scattering amplitudes in gauge theories

    Energy Technology Data Exchange (ETDEWEB)

    Henn, Johannes M. [Institute for Advanced Study, Princeton, NJ (United States). School of Natural Sciences; Plefka, Jan C. [Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik

    2014-03-01

    First monographical text on this fundamental topic. Course-tested, pedagogical and self-contained exposition. Includes exercises and solutions. At the fundamental level, the interactions of elementary particles are described by quantum gauge field theory. The quantitative implications of these interactions are captured by scattering amplitudes, traditionally computed using Feynman diagrams. In the past decade tremendous progress has been made in our understanding of and computational abilities with regard to scattering amplitudes in gauge theories, going beyond the traditional textbook approach. These advances build upon on-shell methods that focus on the analytic structure of the amplitudes, as well as on their recently discovered hidden symmetries. In fact, when expressed in suitable variables the amplitudes are much simpler than anticipated and hidden patterns emerge. These modern methods are of increasing importance in phenomenological applications arising from the need for high-precision predictions for the experiments carried out at the Large Hadron Collider, as well as in foundational mathematical physics studies on the S-matrix in quantum field theory. Bridging the gap between introductory courses on quantum field theory and state-of-the-art research, these concise yet self-contained and course-tested lecture notes are well-suited for a one-semester graduate level course or as a self-study guide for anyone interested in fundamental aspects of quantum field theory and its applications. The numerous exercises and solutions included will help readers to embrace and apply the material presented in the main text.

  12. Employing Helicity Amplitudes for Resummation

    NARCIS (Netherlands)

    Moult, I.; Stewart, I.W.; Tackmann, F.J.; Waalewijn, W.J.

    2015-01-01

    Many state-of-the-art QCD calculations for multileg processes use helicity amplitudes as their fundamental ingredients. We construct a simple and easy-to-use helicity operator basis in soft-collinear effective theory (SCET), for which the hard Wilson coefficients from matching QCD onto SCET are dire

  13. Extracting amplitudes from photoproduction data

    Science.gov (United States)

    Workman, R. L.

    2011-09-01

    We consider the problems associated with amplitude extraction, from meson photoproduction data, over the first resonance regions. The notion of a complete experiment has motivated the FROST program at Jefferson Lab. Exercises applied to pion photoproduction data illustrate the problems to be confronted in any attempt to extract underlying resonance signals from these data (without introducing a model for the resonant process).

  14. Influence of force feedback on grasp force modulation in prosthetic applications: a preliminary study.

    Science.gov (United States)

    Godfrey, Sasha B; Bianchi, Matteo; Bicchi, Antonio; Santello, Marco

    2016-08-01

    In typical movement, humans use a combination of feed-forward and feedback motor control strategies to interact with the world around them. However, when sensory input is impaired or absent, as in the case of various neuropathies or amputation, the ability to perform everyday tasks, like modulating grip force to object weight, can be affected. In this study, we show the results of a preliminary study using a pressure cuff-like force feedback device (CUFF) with the SoftHand Pro (SHP) prosthetic hand. Subjects lifted an object of various weights using their own hand, with the SHP without feedback, and the SHP with force feedback. As expected, significant differences were found between the two SHP conditions and the native hand, but surprisingly not between the SHP conditions. A closer look at the data suggests the feedback may help diminish the overall grip force used during grasping even if it does not alter the grip force modulation to object weight. The lack of significance may be due in part to high intra- and inter-subject variability. Additional training with the CUFF and/or customization of the feedback may enhance the effects and warrants further study.

  15. Force-directed design of a voluntary closing hand prosthesis

    NARCIS (Netherlands)

    De Visser, H.; Herder, J.L.

    2000-01-01

    This paper presents the design of a body-powered voluntary closing prosthetic hand. It is argued that the movement of the fingers before establishing a grip is much less relevant for good control of the object held than the distribution of forces once the object has been contacted. Based on this not

  16. Corticomuscular coherence during hand gripping with DBS and medication in PD patients

    DEFF Research Database (Denmark)

    Sridharan, Kousik Sarathy; Højlund, Andreas; Johnsen, Erik Lisbjerg

    (MEG) from six PD patients performing hand gripping during DBS ON and medicated (levodopa, MED ON) conditions and from ten age-matched healthy controls. Participants performed isotonic contractions (hand gripping) with their right hand, and electromyography (EMG) was recorded from the extensor...... digitorum communis muscle with a belly-tendon montage. We calculated the mean-squared coherence between MEG and the rectified EMG signals. For each group and condition, we selected the maximum CMC value in the beta range (13-30 Hz) within the average of an a priori selection of nine left sensorimotor...

  17. Wear and Grip Loss Evaluation of High Chromium Welding Deposits Applied on Sugar Cane Rolls1

    OpenAIRE

    Diaz Millan, Sebastian; Rugbeño S.A.S; Aguilar Castro, Yesid; Escuela de Ingeniería de Materiales, Universidad del Valle, Cali, Colombia; Casanova García, Gonzalo Fernando; Escuela de Ingeniería Mecánica,Universidad del Valle, Cali, Colombia

    2015-01-01

    Wear on sugar cane rolls is an expensive maintenance problem for the sugar cane industry. Wear produces loss of sucrose extraction and loss of grip of the roll on the bagasse. This paper presents the evaluation of wear and loss of grip of hypoeutectic and hypereutectic high chromium welding deposits applied on ASTM A-36 steel and gray cast iron. A modified ASTM G-65 standard test was used. Wear was produced by the abrasive action of wet bagasse with three levels of mineral extraneous matter. ...

  18. The determination of the operating range of a twin-grip control yoke through biomechanical means

    Science.gov (United States)

    Gaertner, K. P.

    1978-01-01

    A twin-grip control yoke was designed as an ergonomic case study that allows dual axis control inputs, both axes being rotational. Inputs are effected by rotating the grips. How the handles were designed with respect to their shape and size and how the angular range of the control yoke in both rotational axes was evaluated. The control yoke which requires two-hand operation was tested to determine its operating range. The intention of this investigation was to find out the optimal form of the control yoke and the maximum permissible range in both rotating axes. In these experiments controls had no spring resistance.

  19. Grip strength and lower limb extension power in 19-72-year-old Danish men and women

    DEFF Research Database (Denmark)

    Aadahl, Mette; Beyer, Nina; Linneberg, Allan

    2011-01-01

    To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition.......To assess muscular fitness by hand grip strength (HGS) and lower limb extension power (LEP) and to explore associations with age, leisure time physical activity (LTPA) and body composition....

  20. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    DEFF Research Database (Denmark)

    Willems, Sara M; Wright, Daniel J.; Day, Felix R

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of 1...

  1. Large-scale GWAS identifies multiple loci for hand grip strength providing biological insights into muscular fitness

    NARCIS (Netherlands)

    Willems, Sara M.; Wright, D.J.; Day, Felix R.; Trajanoska, Katerina; Joshi, P.K.; Morris, John A.; Matteini, Amy M.; Garton, Fleur C.; Grarup, Niels; Oskolkov, Nikolay; Thalamuthu, Anbupalam; Mangino, Massimo; Liu, Jun; Demirkan, Ayse; Lek, Monkol; Xu, Liwen; Wang, Guan; Oldmeadow, Christopher; Gaulton, Kyle J.; Lotta, Luca A.; Miyamoto-Mikami, Eri; Rivas, Manuel A.; White, Tom; Loh, Po Ru; Aadahl, Mette; Amin, Najaf; Attia, John R.; Austin, Krista; Benyamin, Beben; Brage, Søren; Cheng, Yu Ching; Ciȩszczyk, Paweł; Derave, Wim; Eriksson, Karl Fredrik; Eynon, Nir; Linneberg, Allan; Lucia, Alejandro; Massidda, Myosotis; Mitchell, Braxton D.; Miyachi, Motohiko; Murakami, Haruka; Padmanabhan, Sandosh; Pandey, Ashutosh; Papadimitriou, Ioannis; Rajpal, Deepak K.; Sale, Craig; Schnurr, Theresia M.; Sessa, Francesco; Shrine, Nick; Tobin, Martin D.; Varley, Ian; Wain, Louise V.; Wray, Naomi R.; Lindgren, Cecilia M.; MacArthur, Daniel G.; Waterworth, Dawn M.; McCarthy, Mark I.; Pedersen, Oluf; Khaw, Kay Tee; Kiel, Douglas P.; Pitsiladis, Yannis; Fuku, Noriyuki; Franks, Paul W.; North, Kathryn N.; Duijn, Van C.M.; Mather, Karen A.; Hansen, Torben; Hansson, Ola; Spector, Tim D.; Murabito, Joanne M.; Richards, J.B.; Rivadeneira, Fernando; Langenberg, Claudia; Perry, John R.B.; Wareham, Nick J.; Scott, Robert A.; Oei, Ling; Zheng, Hou Feng; Forgetta, Vincenzo; Leong, Aaron; Ahmad, Omar S.; Laurin, Charles; Mokry, Lauren E.; Ross, Stephanie; Elks, Cathy E.; Bowden, Jack; Warrington, Nicole M.; Murray, Anna; Ruth, Katherine S.; Tsilidis, Konstantinos K.; Medina-Gómez, Carolina; Estrada, Karol; Bis, Joshua C.; Chasman, Daniel I.; Demissie, Serkalem; Enneman, Anke W.; Hsu, Yi Hsiang; Ingvarsson, Thorvaldur; Kähönen, Mika; Kammerer, Candace; Lacroix, Andrea Z.; Li, Guo; Liu, Ching Ti; Liu, Yongmei; Lorentzon, Mattias; Mägi, Reedik; Mihailov, Evelin; Milani, Lili; Moayyeri, Alireza; Nielson, Carrie M.; Sham, Pack Chung; Siggeirsdotir, Kristin; Sigurdsson, Gunnar; Stefansson, Kari; Trompet, Stella; Thorleifsson, Gudmar; Vandenput, Liesbeth; Velde, Van Der Nathalie; Viikari, Jorma; Xiao, Su Mei; Zhao, Jing Hua; Evans, Daniel S.; Cummings, Steven R.; Cauley, Jane; Duncan, Emma L.; Groot, De Lisette C.P.G.M.; Esko, Tonu; Gudnason, Vilmundar; Harris, Tamara B.; Jackson, Rebecca D.; Jukema, J.W.; Ikram, Arfan M.A.; Karasik, David; Kaptoge, Stephen; Kung, Annie Wai Chee; Lehtimäki, Terho; Lyytikäinen, Leo Pekka; Lips, Paul; Luben, Robert; Metspalu, Andres; Meurs, van Joyce B.; Minster, Ryan L.; Orwoll, Erick; Oei, Edwin; Psaty, Bruce M.; Raitakari, Olli T.; Ralston, Stuart W.; Ridker, Paul M.; Robbins, John A.; Smith, Albert V.; Styrkarsdottir, Unnur; Tranah, Gregory J.; Thorstensdottir, Unnur; Uitterlinden, Andre G.; Zmuda, Joseph; Zillikens, M.C.; Ntzani, Evangelia E.; Evangelou, Evangelos; Ioannidis, John P.A.; Evans, David M.; Ohlsson, Claes

    2017-01-01

    Hand grip strength is a widely used proxy of muscular fitness, a marker of frailty, and predictor of a range of morbidities and all-cause mortality. To investigate the genetic determinants of variation in grip strength, we perform a large-scale genetic discovery analysis in a combined sample of 195,

  2. Relationship between grip, pinch strengths and anthropometric variables, types of pitch throwing among Japanese high school baseball pitchers.

    Science.gov (United States)

    Tajika, Tsuyoshi; Kobayashi, Tsutomu; Yamamoto, Atsushi; Shitara, Hitoshi; Ichinose, Tsuyoshi; Shimoyama, Daisuke; Okura, Chisa; Kanazawa, Saeko; Nagai, Ayako; Takagishi, Kenji

    2015-03-01

    Grip and pinch strength are crucially important attributes and standard parameters related to the functional integrity of the hand. It seems significant to investigate normative data for grip and pinch strength of baseball players to evaluate their performance and condition. Nevertheless, few reports have explained the association between grip and pinch strength and anthropometric variables and types of pitch throwing for baseball pitchers. The aim of this study was to measure and evaluate clinical normative data for grip and tip, key, palmar pinch strength and to assess the relationship between these data and anthropometric variables and types of pitch throwing among Japanese high-school baseball pitchers. One hundred-thirty three healthy high school baseball pitchers were examined and had completed a self-administered questionnaire including items related to age, hand dominance, throwing ratio of type of pitch. A digital dynamometer was used to measure grip strength and a pinch gauge to measure tip, key and palmer pinch in both dominant and nondominant side. Body composition was measured by the multi frequency segmental body composition analyzer. Grip strength and tip and palmer pinch strength in dominant side were statistically greater than them in nondominant side (P types of pitches thrown and grip strength and tip, key, palmar pinch strength. Our result provides normative values and evidences for grip and pinch strengths in high school baseball pitchers.

  3. Age trajectories of grip strength: cross-sectional and longitudinal data among 8,342 Danes aged 46 to 102

    DEFF Research Database (Denmark)

    Frederiksen, Henrik; Hjelmborg, Jacob; Mortensen, Jakob

    2006-01-01

    with increasing age. Estimates were obtained by using full-information methods from large population-representative studies. Equations of expected grip strength, as well as tables with sex-, age-, and height-stratified reference data, provide an opportunity to include grip-strength measurement in clinical care...

  4. An investigation of the association between grip strength and hip and knee joint moments in older adults.

    Science.gov (United States)

    Samuel, Dinesh; Rowe, Philip

    2012-01-01

    Grip strength is a predictor of health outcomes but with differing rates of age-related decline in muscle strength, it is unclear whether handgrip is a reliable indicator of lower limb moments. This study investigated the relationship between grip strength and lower extremity moments in community-dwelling older adults. Eighty-two healthy volunteers aged 60-82 years (mean age 73.2 years) performed maximal voluntary contractions of knee and hip extensors and flexors at three positions and at neutral position for hip abductors and adductors using a custom-built dynamometer. Grip strength was measured using an electronic Jamar dynamometer. The relative reduction in muscle strength of 80s age category compared to 60-year-olds ranged from 14% for grip strength to 27% for hip abductors. Peak torque of flexors and extensors of the knee and hip joints were significantly correlated with grip strength and Pearson's correlation coefficients ranged from 0.56 to 0.78 with the highest correlations observed between knee moments and grip strength. "Good" correlation was found but only 31-60% of the variation in grip strength could be related to changes in joint torques. Hence the assumption that grip strength is an indicator of strength in the lower limb would seem unjustified in the healthy older adult.

  5. The cost-effectiveness of grip on challenging behaviour: an economic evaluation of a care programme for managing challenging behaviour

    NARCIS (Netherlands)

    Zwijsen, S.A.; Bosmans, J.E.; Gerritsen, D.L.; Pot, A.M.; Hertogh, C.M.; Smalbrugge, M.

    2016-01-01

    OBJECTIVE: The objective of the study was to evaluate the cost-effectiveness of implementing the Grip on Challenging Behaviour care programme (GRIP) on dementia special care units in comparison with usual care. METHODS: A stepped wedge design was used. Challenging behaviour and quality of life were

  6. Energy Dependence of the πN Amplitude and the Three-Nucleon Interaction

    Science.gov (United States)

    Saito, T.-Y.; Afnan, I. R.

    1995-08-01

    By calculating the contribution of the ππ three-body force to the three-nucleon binding energy in terms of the πN amplitude using perturbation theory, we are able to determine the importance of the energy dependence and the contribution of the different partial waves of the πN amplitude to the three-nucleon force. A separable representation of the non-pole πN amplitude allows us to write the three-nucleon force in terms of the amplitude for NN → NN*, propagation of the NNN* system, and the amplitude for NN* → NN , with N* being the πN quasi-particle amplitude in a given state. The division of the πN amplitude into a pole and non-pole part gives a procedure for the determination of the πNN form factor within the model. The total contribution of the three-body force to the binding energy of the triton for the separable approximation to the Paris nucleon-nucleon potential (PEST) is found to be very small mainly as a result of the energy dependence of the πN amplitude, the cancellation between the S- and P-wave πN amplitudes, and the soft πNN form factor.

  7. Gauge and Gravity Amplitude Relations

    CERN Document Server

    Carrasco, John Joseph M

    2015-01-01

    In these lectures I talk about simplifications and universalities found in scattering amplitudes for gauge and gravity theories. In contrast to Ward identities, which are understood to arise from familiar symmetries of the classical action, these structures are currently only understood in terms of graphical organizational principles, such as the gauge-theoretic color-kinematics duality and the gravitational double-copy structure, for local representations of multi-loop S-matrix elements. These graphical principles make manifest new relationships in and between gauge and gravity scattering amplitudes. My lectures will focus on arriving at such graphical organizations for generic theories with examples presented from maximal supersymmetry, and their use in unitarity-based multi-loop integrand construction.

  8. Infrared singularities in QCD amplitudes

    CERN Document Server

    Gardi, Einan

    2009-01-01

    We review recent progress in determining the infrared singularity structure of on-shell scattering amplitudes in massless gauge theories. We present a simple ansatz where soft singularities of any scattering amplitude of massless partons, to any loop order, are written as a sum over colour dipoles, governed by the cusp anomalous dimension. We explain how this formula was obtained, as the simplest solution to a newly-derived set of equations constraining the singularity structure to all orders. We emphasize the physical ideas underlying this derivation: the factorization of soft and collinear modes, the special properties of soft gluon interactions, and the notion of the cusp anomaly. Finally, we briefly discuss potential multi-loop contributions going beyond the sum-over-dipoles formula, which cannot be excluded at present.

  9. Pulse amplitude modulated chlorophyll fluorometer

    Energy Technology Data Exchange (ETDEWEB)

    Greenbaum, Elias; Wu, Jie

    2015-12-29

    Chlorophyll fluorometry may be used for detecting toxins in a sample because of changes in micro algae. A portable lab on a chip ("LOAC") based chlorophyll fluorometer may be used for toxin detection and environmental monitoring. In particular, the system may include a microfluidic pulse amplitude modulated ("PAM") chlorophyll fluorometer. The LOAC PAM chlorophyll fluorometer may analyze microalgae and cyanobacteria that grow naturally in source drinking water.

  10. Grip and detachment of locusts on inverted sandpaper substrates

    Energy Technology Data Exchange (ETDEWEB)

    Han Longbao; Wang Zhouyi; Ji Aihong; Dai Zhendong, E-mail: zddai@nuaa.edu.cn [Institute of Bio-inspired Structure and Surface Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing 210016 (China)

    2011-12-15

    Locusts (Locusta migratoria manilensis) are characterized by their strong flying and grasping ability. Research on the grasping mechanism and behaviour of locusts on sloping substrates plays an important role in elucidating the mechanics of hexapod locomotion. Data on the maximum angles of slope at which locusts can grasp stably (critical angles of detachment) were obtained from high-speed video recordings at 215 fps. The grasping forces were collected by using two sensors, in situations where all left legs were standing on one and the right legs on the other sensor plate. These data were used to illustrate the grasping ability of locusts on slopes with varying levels of roughness. The grasping morphologies of locusts' bodies and tarsi were observed, and the surface roughness as well as diameters of their claw tips was measured under a microscope to account for the grasping mechanism of these insects on the sloping substrate. The results showed that the claw tips and part of the pads were in contact with the inverted substrate when the mean particle diameter was in the range of 15.3-40.5 {mu}m. The interaction between pads and substrates may improve the stability of contact, and claw tips may play a key role in keeping the attachment reliable. A model was developed to explain the significant effects of the relative size of claw tips and mean particle diameter on grasping ability as well as the observed increase in lateral force (2.09-4.05 times greater than the normal force during detachment) with increasing slope angle, which indicates that the lateral force may be extremely important in keeping the contact reliable. This research lays the groundwork for the probable design and development of biomimetic robotics.

  11. Does grip strength on the unaffected side of patients with hemiparetic stroke reflect the strength of other ipsilateral muscles?

    Science.gov (United States)

    Takahashi, Jumpei; Nishiyama, Toru; Matsushima, Yoshimasa

    2017-01-01

    [Purpose] Grip strength is used as an indicator of overall body muscular strength. However, most studies on grip strength have been performed in healthy people, and no study has evaluated it in the unaffected side of patients with hemiparetic stroke. The purpose of this study was to determine if grip strength on the unaffected side of patients with hemiparetic stroke correlates with the strength of other ipsilateral musculature. [Subjects and Methods] The maximal strengths of the muscles on the unaffected side of 31 patients with hemiparetic stroke were measured, and correlation coefficients were calculated. [Results] The results revealed significant positive correlations between grip strength on the unaffected side and the strength of the other ipsilateral muscle groups, with relatively high correlations being observed for the upper extremity muscle groups. [Conclusion] This suggests that grip strength on the unaffected side of patients with hemiparetic stroke can be used as a simple way to estimate overall strength on that side.

  12. All-Multiplicity Amplitudes with Massive Scalars

    CERN Document Server

    Forde, D; Forde, Darren; Kosower, David A.

    2005-01-01

    We compute two infinite series of tree-level amplitudes with a massive scalar pair and an arbitrary number of gluons. We provide results for amplitudes where all gluons have identical helicity, and amplitudes with one gluon of opposite helicity. These amplitudes are useful for unitarity-based one-loop calculations in nonsupersymmetric gauge theories generally, and QCD in particular.

  13. Crisis in Amplitude Control Hides in Multistability

    Science.gov (United States)

    Li, Chunbiao; Sprott, Julien Clinton; Xing, Hongyan

    2016-12-01

    A crisis of amplitude control can occur when a system is multistable. This paper proposes a new chaotic system with a line of equilibria to demonstrate the threat to amplitude control from multistability. The new symmetric system has two coefficients for amplitude control, one of which is a partial amplitude controller, while the other is a total amplitude controller that simultaneously controls the frequency. The amplitude parameter rescales the basins of attraction and triggers a state switch among different states resulting in a failure of amplitude control to the desired state.

  14. Calculation of multi-loop superstring amplitudes

    Science.gov (United States)

    Danilov, G. S.

    2016-12-01

    The multi-loop interaction amplitudes in the closed, oriented superstring theory are obtained by the integration of local amplitudes. The local amplitude is represented by a sum over the spinning string local amplitudes. The spinning string local amplitudes are given explicitly through super-Schottky group parameters and through interaction vertex coordinates on the (1| 1) complex, non-split supermanifold. The obtained amplitudes are free from divergences. They are consistent with the world-sheet spinning string symmetries. The vacuum amplitude vanishes along with 1-, 2- and 3-point amplitudes of massless states. The vanishing of the above-mentioned amplitude occurs after the integration of the corresponding local amplitude has been performed over the super-Schottky group limiting points and over interaction vertex coordinate, except for those (3| 2) variables which are fixed due to SL(2)-symmetry.

  15. Differential roles for NSF and GRIP/ABP in AMPA receptor cycling.

    Science.gov (United States)

    Braithwaite, Steven P; Xia, Houhui; Malenka, Robert C

    2002-05-14

    alpha-Amino-3-hydroxy-5-methylisoxazole-4-propionic acid receptor (AMPAR) stability and movement at synapses are important factors controlling synaptic strength. Here, we study the roles of proteins [N-ethylmaleimide-sensitive fusion protein (NSF), glutamate receptor AMPAR binding protein (ABP)-interacting protein (GRIP)/(ABP), and protein interacting with C-kinase-1 (PICK1) that interact with the GluR2 subunit in the control of the surface expression and cycling of AMPARs. Epitope-tagged GluR2 formed functional receptors that exhibited targeting to synaptic sites. Constructs in which binding to NSF, PDZ proteins (GRIP/ABP and PICK1), or GRIP/ABP alone was eliminated each exhibited normal surface targeting and constitutive cycling. The lack of NSF binding, however, resulted in receptors that were endocytosed to a greater extent than wild-type receptors in response to application of AMPA or N-methyl-d-aspartate (NMDA). Conversely, the behavior of the GluR2 mutants incapable of binding to GRIP/ABP suggests that these PDZ proteins play a role in the stabilization of an intracellular pool of AMPARs that have been internalized on stimulation, thus inhibiting their recycling to the synaptic membrane. These results provide further evidence for distinct functional roles of GluR2-interacting proteins in AMPAR trafficking.

  16. Eyes, Grip and Gesture as Objective Indicators of Intentions and Attention

    DEFF Research Database (Denmark)

    Mortensen, Ditte Hvas

    This poster abstract presents the first part of a study concerning the use of information about gaze, grip and gesture to create non-command interaction. The experiment reported here seeks to establish the occurrence of patterns in nonverbal communication,  which may be used in an activity aware...

  17. EFFECT OF ECCENTRIC EXERCISE PROGRAMME ON PAIN AND GRIP STRENGTH FOR SUBJECTS WITH MEDIAL EPICONDYLITIS

    Directory of Open Access Journals (Sweden)

    Mishra Prashant Akhilesh

    2014-04-01

    Full Text Available Background and Objective: Therapeutic eccentric exercise may provide both a structural and functional benefit during tendinopathy rehabilitation. The objective is to find the effect of eccentric exercises on improvement of pain and grip strength for subjects with Medial Epicondylitis. Method: Pre to post test experimental study design randomized thirty subjects with medial epicondylitis, 15 each into Group A and Group B. Group B subjects were treated with conventional therapy and Eccentric exercises. Group A subjects were treated with conventional therapy. Results: When means of post intervention were compared using Independent ‘t’ between groups there was no statistically significant difference in improvements obtained in VAS scores and grip strength. There was a statistically significant change in means of VAS score and Grip strength when means were analyzed by using Paired‘t’ test and Wilcoxon signed rank test within the groups with positive percentage of change. Conclusion: It is concluded that four weeks of Eccentric Exercise Programme combined with conventional therapy shown significant effect on improving pain and Grip strength, however the improvement obtained has no difference when compared with control conventional treatment for Subjects with Medial Epicondylitis.

  18. The effect of precision and power grips on activations in human auditory cortex

    Directory of Open Access Journals (Sweden)

    Patrik Alexander Wikman

    2015-10-01

    Full Text Available The neuroanatomical pathways interconnecting auditory and motor cortices play a key role in current models of human auditory cortex (AC. Evidently, auditory-motor interaction is important in speech and music production, but the significance of these cortical pathways in other auditory processing is not well known. We investigated the general effects of motor responding on AC activations to sounds during auditory and visual tasks. During all task blocks, subjects detected targets in the designated modality, reported the relative number of targets at the end of the block, and ignored the stimuli presented in the opposite modality. In each block, they were also instructed to respond to targets either using a precision grip, power grip, or to give no overt target responses. We found that motor responding strongly modulated AC activations. First, during both visual and auditory tasks, activations in widespread regions of AC decreased when subjects made precision and power grip responses to targets. Second, activations in AC were modulated by grip type during the auditory but not during the visual task. Further, the motor effects were distinct from the strong attention-related modulations in AC. These results are consistent with the idea that operations in AC are shaped by its connections with motor cortical regions.

  19. Getting a grip on numbers : Numerical magnitude priming in object grasping

    NARCIS (Netherlands)

    Lindemann, Oliver; Abolafia, Juan A.; Girardi, Giovanna; Bekkering, Harold

    2007-01-01

    To investigate the functional connection between numerical cognition and action planning, the authors required participants to perform different grasping responses depending on the parity status of Arabic digits. The results show that precision grip actions were initiated faster in response to small

  20. Frimand Needle Holder Reduces Suturing Time and Surgical Stress When Suturing in Palm Grip.

    Science.gov (United States)

    Frimand Rönnow, Carl-Fredrik; Jeppsson, Bengt; Thorlacius, Henrik

    2016-06-01

    Purpose The Frimand needle holder (FNH) was developed to facilitate palm grip suturing. In the present study, we wanted to examine the impact of the FNH compared with a conventional Hegar-styled needle holder (HSNH) on suture time and surgical stress. Methods Thirty-two surgeons were enrolled and they performed sets of 3 continuous sutures on a polyurethane pad with premarked insert and exit points and the time for suturing was measured. Surgical stress was quantified by having the surgeons to perform 10 release maneuvers with the FNH and the HSNH on a needle attached to a scale. The scale sent 5 values per second to a computer. The first measurement of each series was regarded as the starting weight and all subsequent measurements were either regarded as neutral, pressure or traction. The sum of these measurements represented total surgical stress. Results We found that all surgeons reduced their median suturing time by 16% when using FNH for palm grip suturing with no difference between junior and senior surgeons. Moreover, it was observed that FNH decreased median surgical stress by 62% for all surgeons performing palm grip suturing compared with a conventional HSNH. Conclusion We conclude that the FNH reduces suture time and surgical stress compared with HSNH when performing palm grip suturing. These findings warrant studies in surgical patients in order to evaluate the potential clinical impact of FNH.

  1. First flight of the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument

    CERN Document Server

    Duncan, Nicole; Shih, A Y; Hurford, G J; Bain, H M; Amman, M; Mochizuki, B A; Hoberman, J; Olson, J; Maruca, B A; Godbole, N M; Smith, D M; Sample, J; Kelley, N A; Zoglauer, A; Caspi, A; Kaufmann, P; Boggs, S; Lin, R P

    2016-01-01

    The Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in Jan 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV) with enhanced imaging, spectroscopy and polarimetry. GRIPS is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing HXRs and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) include 3D position-sensi...

  2. Grip Strength as a Marker of Hypertension and Diabetes in Healthy Weight Adults.

    Science.gov (United States)

    Mainous, Arch G; Tanner, Rebecca J; Anton, Stephen D; Jo, Ara

    2015-12-01

    Muscle strength may play a role in cardiometabolic disease. We examined the relationship between hand grip strength and diabetes and hypertension in a sample of healthy weight adults. In 2015, we analyzed the National Health and Nutrition Examination Survey 2011-2012 for adults aged ≥20 years with healthy BMIs (between 18.5 and Hypertension was based on measured blood pressure and reported hypertension diagnosis. Individuals with undiagnosed diabetes compared with individuals without diabetes had lower grip strength (51.9 vs 69.8, p=0.0001), as did individuals with diagnosed diabetes compared with individuals without diabetes (61.7 vs 69.8, p=0.008). Mean grip strength was lower among individuals with undiagnosed hypertension compared with individuals without hypertension (63.5 vs 71.5, p=0.008) as well as among individuals with diagnosed hypertension compared with those without hypertension (60.8 vs 71.5, phypertension (β=-6.6, p=0.004) and diagnosed hypertension (β=-4.27, p=0.04) compared with individuals without hypertension. Among healthy weight adults, combined grip strength is lower in individuals with diagnosed and undiagnosed diabetes and hypertension. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  3. Enhanced independence: experiences after regaining grip function in people with tetraplegia.

    Science.gov (United States)

    Wangdell, Johanna; Carlsson, Gunnel; Fridén, Jan

    2013-01-01

    To explore how surgical reconstruction of grip affects everyday life for patients with tetraplegia, with special emphasis on patients perspective of their perceived changes. Qualitative method. Eleven people (aged 22-73) with tetraplegia who had undergone surgical reconstruction to restore grip function. Qualitative interviews were conducted 7-17 months after surgery and analysed using Grounded theory. The core concept describing the participants experienced gains after grip reconstructive surgery was "enhanced independence". It was associated with changes in both practical and psychological aspects of independence. Practical aspects identified were: "perform more activities", "smoother everyday life", "renewed ability to participate in social activities", "less dependence on assistance" and "less restricted by physical environment". Psychological aspects of independence included "regained privacy", "increased manageability", "regained identity", "recapture a part of the body" and "share positive experiences with relatives and friends". Encompassing all categories was the concept "self-efficacy in hand control". It was seen as a result included in the enhanced independency core but also as an important factor for the development of all the other categories. Participants in this study experienced enhanced independence after grip reconstructive surgery and rehabilitation. The enhanced independence included both practical and physical aspects and it influenced all domains using the International Classification of Function, Disability and Health model; body function and structure, activities, participation, personal factors and environmental factors. Implications for Rehabilitation Patients with tetraplegia experience grip reconstruction as a useful intervention, an enhanced independence, related to their improved hand control. The increased hand control impacted not only physical aspects but also practical and psychological aspects. It also influenced social and

  4. Electromagnet Gripping in Iron Foundry Automation Part II: Simulation

    Directory of Open Access Journals (Sweden)

    Rhythm Suren Wadhwa

    2012-03-01

    Full Text Available This paper compares the simulation and initial experimental results for robust part handling by radially symmetric cylindrical electromagnetic gripper heads, that are used in foundry manufacturing assembly operation. Knowledge of the direct holding force is essential to determine if a given electromagnet is capable of preventing part slipping during pick and place operation. Energy based model and the magnetic circuit model have been described. The latter is developed further and compared with results from a FEA software. It was found that the magnetic circuit model, although simple in form, was limited in its ability to accurately predict the holding force over the entire range of conditions investigated. The shortcomings in the model were attributed to its inability to accurately model the leakage flux and non-uniform distribution of the magnetic flux. A finite element allowed for the ability to couple the mechanical and magnetic models. The finite element model was used to predict the magnetic field based off the solutions to the mechanical (sigma and the magnetic model (B.

  5. The energy dependence of the $\\pi$N amplitude and the three-nucleon interaction

    CERN Document Server

    Saitô, T; Saito, T Y

    1994-01-01

    By calculating the contribution of the \\pi-\\pi three-body force to the three-nucleon binding energy in terms of the \\pi N amplitude using perturbation theory, we are able to determine the importance of the energy dependence and the contribution of the different partial waves of the \\pi N amplitude to the three-nucleon force. A separable representation of the non-pole \\pi N amplitude allows us to write the three-nucleon force in terms of the amplitude for NN\\rightarrow NN^*, propagation of the NNN^* system, and the amplitude for NN^*\\rightarrow NN, with N^* being the \\pi N quasi-particle amplitude in a given state. The division of the \\pi N amplitude into a pole and non-pole gives a procedure for the determination of the \\pi NN form factor within the model. The total contribution of the three-body force to the binding energy of the triton for the separable approximation to the Paris nucleon-nucleon potential (PEST) is found to be very small mainly as a result of the energy dependence of the \\pi N amplitude, th...

  6. Amplitude recruitment of cochlear potential

    Institute of Scientific and Technical Information of China (English)

    LI Xingqi; SUN Wei; SUN Jianhe; YU Ning; JIANG Sichang

    2001-01-01

    Intracellular recordings were made from outer hair cells (OHC) and the cochlear microphonics (CM) were recorded from scala media (SM) in three turn of guinea pig cochlea,the compound action potential (CAP) were recorded at the round window (RW) before and after the animal were exposed to white noise. The results suggest that the nonlinear properties with “saduration” of Input/output (I/O) function of OHC AC recepter potential and CM were founded; the nonlinear properties with “Low”, “Platean” and “high” of CAP also were investigated. After explosion, the threshold shift of CAP has about 10 dB. The I/O of OHC responses and CM were changed in a linearizing (i.e., nonlinearity loss), the “platean” of I/O CAP disappeared and the growth rate of CAP amplitude were larger than before explosion. The response amplitude recruitment of OHC appears to result from reduction in gain (i.e., hearing loss); It was due to the nonlinear growth function of OHC receptor potentials was changed in linearzing that the basilar membrance motion was changed in linearizing. Since intensity coding in the inner ear depends on an interactions of nonlinear basilar membrance and nerve fibers. So that it must lead to a linearizing of CAP as input responses.

  7. Measuring the local pressure amplitude in microchannel acoustophoresis

    DEFF Research Database (Denmark)

    Barnkob, Rune; Augustsson, Per; Laurell, Thomas

    2010-01-01

    A new method is reported on how to measure the local pressure amplitude and the Q factor of ultrasound resonances in microfluidic chips designed for acoustophoresis of particle suspensions. The method relies on tracking individual polystyrene tracer microbeads in straight water-filled silicon...... of the microbeads. From the curve fits we obtain the acoustic energy density, and hence the pressure amplitude as well as the acoustophoretic force. By plotting the obtained energy densities as a function of applied frequency, we obtain Lorentzian line shapes, from which the resonance frequency and the Q factor...... for each resonance peak are derived. Typical measurements yield acoustic energy densities of the order of 10 J/m3, pressure amplitudes of 0.2 MPa, and Q factors around 500. The observed half wavelength of the transverse acoustic pressure wave is equal within 2% to the measured width w = 377 m...

  8. Slippage Detection in Gripping Fruits and Vegetables for Agricultural Robot%农业机器人果蔬抓取中滑觉检测研究

    Institute of Scientific and Technical Information of China (English)

    周俊; 朱树平

    2013-01-01

    A kind of sensitive slippage sensor was developed by using piezoresistor, and a slippage observation system was constructed. The technique of STFT was applied to analyze the spectral information of slippage signal. Then slippage signal was distinguished with the signal resulted from different normal griping forces by using the result of DWT. The experimental results showed that the slippage signal was able to be effectively extracted regardless of different normal gripping force. At last, the experiment of gripping force adjustment was carried out by using two parallel fingers hand equipped with the designed slippage sensor. The experimental results of grasping actual fruits and vegetables demonstrated the promise of this slippage sensor in the agricultural picking robot.%利用压敏电阻作为敏感材料制作了一种灵敏的滑觉传感器,构建了滑觉信号观测系统.用短时傅里叶变换方法分析了滑觉信号的频谱特征,并运用离散小波变换结果来区分法向抓取力变化与实际发生的滑动信号,以使滑动信号检测结果不受法向抓取力变化的影响,试验结果表明滑觉检测的稳定性.运用二指平行手爪进行了实际的果蔬抓取试验,验证了基于滑觉检测的抓取力调节效果.

  9. Power grip, pinch grip, manual muscle testing or thenar atrophy – which should be assessed as a motor outcome after carpal tunnel decompression? A systematic review

    Directory of Open Access Journals (Sweden)

    Kale Swati

    2007-11-01

    Full Text Available Abstract Background Objective assessment of motor function is frequently used to evaluate outcome after surgical treatment of carpal tunnel syndrome (CTS. However a range of outcome measures are used and there appears to be no consensus on which measure of motor function effectively captures change. The purpose of this systematic review was to identify the methods used to assess motor function in randomized controlled trials of surgical interventions for CTS. A secondary aim was to evaluate which instruments reflect clinical change and are psychometrically robust. Methods The bibliographic databases Medline, AMED and CINAHL were searched for randomized controlled trials of surgical interventions for CTS. Data on instruments used, methods of assessment and results of tests of motor function was extracted by two independent reviewers. Results Twenty-two studies were retrieved which included performance based assessments of motor function. Nineteen studies assessed power grip dynamometry, fourteen studies used both power and pinch grip dynamometry, eight used manual muscle testing and five assessed the presence or absence of thenar atrophy. Several studies used multiple tests of motor function. Two studies included both power and pinch strength and reported descriptive statistics enabling calculation of effect sizes to compare the relative responsiveness of grip and pinch strength within study samples. The study findings suggest that tip pinch is more responsive than lateral pinch or power grip up to 12 weeks following surgery for CTS. Conclusion Although used most frequently and known to be reliable, power and key pinch dynamometry are not the most valid or responsive tools for assessing motor outcome up to 12 weeks following surgery for CTS. Tip pinch dynamometry more specifically targets the thenar musculature and appears to be more responsive. Manual muscle testing, which in theory is most specific to the thenar musculature, may be more

  10. 基于复合滑移理论的轮胎抓地状态建模与验证%Construction and verification of tire grip state based on combined-slip theory

    Institute of Scientific and Technical Information of China (English)

    李波; 赵又群; 臧利国; 王健; 张明杰

    2014-01-01

    In order to obtain accurate estimation of the tire gripping state, a model on the interaction between the tire and the ground playing a key role in the driving stability and the security of vehicles was studied in this paper. Adopting the Brush Model of tire and considering the contact differences between the longitudinal slip and the lateral slip considered, an improved Brush Model of tire based on the compound slip theory was proposed for modeling the tire gripping state. The Brush Model is an important method to predict the force between the tire and the ground, and in this simplified tire model, the contact state between the tire and the road can be divided into the adhesion area and the slip area. The forces in the adhesion area come from the static friction between the tread of rigid carcass and the road, and the forces in the slip area come from the sliding friction between the tread and the road. The innovation of this article is to distinguish the friction types between the adhesion section and the slip section, and the friction coefficients between the longitudinal and the lateral. The tire’s ability to grip is the critical factor of driving, braking, steering and other performances of the vehicle, which comes from the horizontal friction between the tire and the ground. Various active control technologies have been developed to improve the drivability and applied to the active safety system of commercial vehicles. Some experts have raised the protection function of the limit manipulation cases, which was applied into the active manipulation controller. The ratio of the horizontal force and the vertical force was defined as the adhesion coefficient to analyze vehicle adhesion state in some papers. However, it only reflected the change of tire gripping, but the sliding state (the dangerous degree of tire slipping) could not be predicted due to the less accurate model or the complex parameter structure. The state of tire gripping was determined by the

  11. First flight of the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument

    Science.gov (United States)

    Duncan, Nicole; Saint-Hilaire, P.; Shih, A. Y.; Hurford, G. J.; Bain, H. M.; Amman, M.; Mochizuki, B. A.; Hoberman, J.; Olson, J.; Maruca, B. A.; Godbole, N. M.; Smith, D. M.; Sample, J.; Kelley, N. A.; Zoglauer, A.; Caspi, A.; Kaufmann, P.; Boggs, S.; Lin, R. P.

    2016-07-01

    The Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument is a balloon-borne telescope designed to study solar- are particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of are emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM gridimaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi

  12. Relations Between Helicity Coupling Amplitude and L-S Coupling Amplitude

    Institute of Scientific and Technical Information of China (English)

    WU Ning; RUAN Tu-Nan

    2001-01-01

    Relations between helicity coupling amplitude and L-S coupling amplitude are discussed. The equivalence condition for these two kinematic analysis methods and the limitations of the L-S coupling amplitude are also studied in this paper.``

  13. Grassmannian geometry of scattering amplitudes

    CERN Document Server

    Arkani-Hamed, Nima; Cachazo, Freddy; Goncharov, Alexander; Postnikov, Alexander; Trnka, Jaroslav

    2016-01-01

    Outlining a revolutionary reformulation of the foundations of perturbative quantum field theory, this book is a self-contained and authoritative analysis of the application of this new formulation to the case of planar, maximally supersymmetric Yang–Mills theory. The book begins by deriving connections between scattering amplitudes and Grassmannian geometry from first principles before introducing novel physical and mathematical ideas in a systematic manner accessible to both physicists and mathematicians. The principle players in this process are on-shell functions which are closely related to certain sub-strata of Grassmannian manifolds called positroids - in terms of which the classification of on-shell functions and their relations becomes combinatorially manifest. This is an essential introduction to the geometry and combinatorics of the positroid stratification of the Grassmannian and an ideal text for advanced students and researchers working in the areas of field theory, high energy physics, and the...

  14. Holonomy-flux spinfoam amplitude

    CERN Document Server

    Perini, Claudio

    2012-01-01

    We introduce a holomorphic representation for the Lorentzian EPRL spinfoam on arbitrary 2-complexes. The representation is obtained via the Ashtekar-Lewandowski-Marolf-Mour\\~ao-Thiemann heat kernel coherent state transform. The new variables are classical holonomy-flux phase space variables $(h,X)\\simeq \\mathcal T^*SU(2)$ of Hamiltonian loop quantum gravity prescribing the holonomies of the Ashtekar connection $A=\\Gamma + \\gamma K$, and their conjugate gravitational fluxes. For small heat kernel `time' the spinfoam amplitude is peaked on classical space-time geometries, where at most countably many curvatures are allowed for non-zero Barbero-Immirzi parameter. We briefly comment on the possibility to use the alternative flipped classical limit.

  15. Constructing Amplitudes from Their Soft Limits

    Energy Technology Data Exchange (ETDEWEB)

    Boucher-Veronneau, Camille; Larkoski, Andrew J.; /SLAC

    2011-12-09

    The existence of universal soft limits for gauge-theory and gravity amplitudes has been known for a long time. The properties of the soft limits have been exploited in numerous ways; in particular for relating an n-point amplitude to an (n-1)-point amplitude by removing a soft particle. Recently, a procedure called inverse soft was developed by which 'soft' particles can be systematically added to an amplitude to construct a higher-point amplitude for generic kinematics. We review this procedure and relate it to Britto-Cachazo-Feng-Witten recursion. We show that all tree-level amplitudes in gauge theory and gravity up through seven points can be constructed in this way, as well as certain classes of NMHV gauge-theory amplitudes with any number of external legs. This provides us with a systematic procedure for constructing amplitudes solely from their soft limits.

  16. Constructing amplitudes from their soft limits

    Science.gov (United States)

    Boucher-Veronneau, Camille; Larkoski, Andrew J.

    2011-09-01

    The existence of universal soft limits for gauge-theory and gravity amplitudes has been known for a long time. The properties of the soft limits have been exploited in numerous ways; in particular for relating an n-point amplitude to an ( n - 1)-point amplitude by removing a soft particle. Recently, a procedure called inverse soft was developed by which "soft" particles can be systematically added to an amplitude to construct a higher-point amplitude for generic kinematics. We review this procedure and relate it to Britto-Cachazo-Feng-Witten recursion. We show that all tree-level amplitudes in gauge theory and gravity up through seven points can be constructed in this way, as well as certain classes of NMHV gauge-theory amplitudes with any number of external legs. This provides us with a systematic procedure for constructing amplitudes solely from their soft limits.

  17. Limiting amplitudes of fully nonlinear interfacial tides and solitons

    Science.gov (United States)

    Aguiar-González, Borja; Gerkema, Theo

    2016-08-01

    A new two-fluid layer model consisting of forced rotation-modified Boussinesq equations is derived for studying tidally generated fully nonlinear, weakly nonhydrostatic dispersive interfacial waves. This set is a generalization of the Choi-Camassa equations, extended here with forcing terms and Coriolis effects. The forcing is represented by a horizontally oscillating sill, mimicking a barotropic tidal flow over topography. Solitons are generated by a disintegration of the interfacial tide. Because of strong nonlinearity, solitons may attain a limiting table-shaped form, in accordance with soliton theory. In addition, we use a quasi-linear version of the model (i.e. including barotropic advection but linear in the baroclinic fields) to investigate the role of the initial stages of the internal tide prior to its nonlinear disintegration. Numerical solutions reveal that the internal tide then reaches a limiting amplitude under increasing barotropic forcing. In the fully nonlinear regime, numerical experiments suggest that this limiting amplitude in the underlying internal tide extends to the nonlinear case in that internal solitons formed by a disintegration of the internal tide may not reach their table-shaped form with increased forcing, but appear limited well below that state.

  18. A Note on Loop Amplitudes in QED

    CERN Document Server

    Brandhuber, Andreas; Vincon, Massimiliano

    2009-01-01

    We consider the two-loop four-point amplitude in N=2 super QED, and show that there exists an approximate recursive structure similar to that captured by the ABDK/BDS ansatz for MHV amplitudes in N=4 super Yang-Mills. Furthermore, we present a simple relation between the box coefficients of one-loop photon MHV amplitudes in (super) QED, and sums of box coefficients of one-loop MHV amplitudes in (super) Yang-Mills.

  19. Freezing grip - new application of the Peltier technology; Gefriergreifer - neue Anwendung der Peltier-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, L.; Stephan, J. [NAISS GmbH, Berlin (Germany)

    2002-12-01

    The rising requirements in efficiency and quality lead to products of in addition integration and functionality with ever smaller components. In addition new materials with improved characteristics are used e.g. GRP components plastics. Due to the characteristics of miniature units and new materials an automated assembling process becomes ever more difficult. With CRYO grip gripping tools were developed, which transport material units and carefully. (orig.) [German] Die steigenden Anforderungen an Leistungsfaehigkeit und Qualitaet fuehren zu Produkten hoeherer Integration und Funktionalitaet mit immer kleineren Komponenten. Ausserdem kommt es zur Anwendung neuer Werkstoffe mit verbesserten Eigenschaften wie z. B. Faserverbundkunststoffen. Aufgrund der Eigenschaften von Miniaturbauteilen und neuer Materialien wird ein automatisierter Montageprozess immer schwieriger. Mit CRYO-Greifern sind Greifwerkzeuge entwickelt worden, die materialschonend und sicher solche Bauteile transportieren. (orig.)

  20. A Monte Carlo-tuned model of the flow in the NorthGRIP area

    DEFF Research Database (Denmark)

    Grinsted, Aslak; Dahl-Jensen, Dorthe

    2002-01-01

    The North Greenland Icecore Project (NorthGRIP) drill site was chosen in order to obtain a good Eemian record. At the present depth, 3001m, the Eemian interstadial has yet to be seen. Clearly the flow in this area is poorly understood and needs further investigation. After a review of specific...... no Eemian is observed is a high basal melt rate (2.7mm/a). The melting is a consequence of a higher geothermal heat flux than the expected 51mW/m^2 of the Precambrian shield. From our analyses it is concluded that the geothermal heat flux at NorthGRIP is 98mW/m^2.The high basalmelt rate also gives rise...

  1. Dynamics of Crystal Formation in the Greenland NorthGRIP Ice Core

    CERN Document Server

    Mathiesen, J; Jensen, M H; Levinsen, M; Olesen, P; Dahl-Jensen, D; Svensson, A; Mathiesen, Joachim; Ferkinghoff-Borg, Jesper; Jensen, Mogens H.; Levinsen, Mogens; Olesen, Poul; Dahl-Jensen, Dorthe; Svensson, Anders

    2003-01-01

    The North Greenland Ice Core Project (NorthGRIP) provides paleoclimatic information back to at least 115 kyr before present [Dahl-Jensen et al., 2002]. Each year, precipitation on the ice sheet covers it with a new layer of snow, which gradually transforms into ice crystals as the layer sinks into the ice sheet. The size distribution of ice crystals has been measured at selected depths in the upper 880 m of the NorthGRIP ice core [Svensson et al., 2003b], which cover a time span of 5300 years. The distributions change with time toward a universal curve, indicating a common underlying physical process in the formation of crystals. We identify this process as an interplay between fragmentation of the crystals and diffusion of their grain boundaries. The process is described by a two-parameter differential equation to which we obtain the exact solution. The solution is in excellent agreement with the experimentally observed distributions.

  2. Randomized clinical trial of self-gripping mesh versus sutured mesh for Lichtenstein hernia repair

    DEFF Research Database (Denmark)

    Jorgensen, L N; Sommer, T; Assaadzadeh, S;

    2012-01-01

    between the groups in postoperative complications (33·7 versus 40·4 per cent; P = 0·215), rate of recurrent hernia within 1 year (1·2 per cent in both groups) or quality of life. CONCLUSION: The avoidance of suture fixation using a self-gripping mesh was not accompanied by a reduction in chronic symptoms......BACKGROUND: Many patients develop discomfort after open repair of a groin hernia. It was hypothesized that suture fixation of the mesh is a cause of these symptoms. METHODS: This patient- and assessor-blinded randomized multicentre clinical trial compared a self-gripping mesh (Parietene Progrip......(®) ) and sutured mesh for open primary repair of uncomplicated inguinal hernia by the Lichtenstein technique. Patients were assessed before surgery, on the day of operation, and at 1 and 12 months after surgery. The primary endpoint was moderate or severe symptoms after 12 months, including a combination...

  3. Coefficient of variation in maximal and feigned static and dynamic grip efforts.

    Science.gov (United States)

    Dvir, Z

    1999-01-01

    The purpose of this study was to investigate the validity of the coefficient of variation as an identifier of feigned grip effort. Seventeen healthy female aged 20 to 25 yr participated in the study. Maximal and feigned efforts were measured isometrically and isokinetically (concentric and eccentric) using the Jamar and KinCom dynamometers, respectively. Findings indicated that, in all situations, the coefficient of variation derived from the maximal effort was significantly (P < 0.0001) lower than that derived from the feigned effort. However, the extent of overlapping between the two was sufficiently large to render the test sensitivities very low. Consequently, regardless of the measurement method, the coefficient of variation is not a valid tool for identifying feigned grip effort in healthy subjects.

  4. First flight of the Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS)

    Science.gov (United States)

    Saint-Hilaire, Pascal; Shih, Albert Y.; Duncan, Nicole; Bain, Hazel; Maruca, Bennett A.; Kelley, Nicole; Godbole, Niharika; Kaufmann, Pierre; Caspi, Amir; Sample, John; Hoberman, Jane; Mochizuki, Brent; Olson, Jerry; Boggs, Steven E.; Zoglauer, Andreas; Hurford, Gordon J.; Smith, David M.; Tajima, Hiroyasu; Amman, Mark

    2016-05-01

    The Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) high altitude balloon payload was successfully flown in January 2016 from Antarctica (Jan 19 to Jan 30).GRIPS provides a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma ray/hard X-ray emissions from ~20 keV to >~10 MeV. GRIPS’s goal is to address questions raised by recent solar flare observations regarding particle acceleration and energy release, such as: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? The spectrometer/polarimeter consists of six 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution gamma-ray energies (12.5 arcsec FWHM), sufficient to separate 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs, with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS was also equipped with active BGO shields, and three piggy-back instruments: a solar terahertz radiometer (Solar-T), a hard X-ray spectrometer (SMASH), and a sonic anemometer (TILDAE).We will present an overview of GRIPS's first flight, the performance of its instruments and subsystems, including the solar pointing and aspect systems, and the current progress of our data analysis.

  5. Effect of paddle grip on segmental fluid distribution in elite slalom paddlers.

    Science.gov (United States)

    Bílý, Milan; Baláš, Jiří; Martin, Andrew John; Cochrane, Darryl; Coufalová, Klára; Süss, Vladimír

    2013-01-01

    Issues of high levels of muscular asymmetry have been associated with injury risk, and therefore have potential implications for decremental performance at the elite sport level. The aim of this current study was to assess the relationship between the segmental fluid distribution and the paddle grip in elite male and female slalom kayakers and canoeists. Eighty-four world-cup competitors (61 males and 23 females) took part in the study. Impedance analysis was used to assess segmental fluid asymmetry. The effect of paddle grip (loose/fixed hand in kayakers, lower/upper hand in canoeists), morphological dominance (dominant/non-dominant) and discipline (canoe/kayak) were evaluated by repeated measures ANOVA. The findings indicated a significant effect of paddle grip in canoeists on morphological asymmetry in upper limbs (arm of lower paddle hand mean fluid distribution 3.28, s=0.43 litres; arm of upper paddle hand mean fluid distribution 3.19, s=0.41 litres; P=0.000, [Formula: see text]=0.33). The sternmen demonstrated higher asymmetry between the arms of upper and lower paddle hand (mean 0.11, s=0.04 litres, P=0.000, [Formula: see text]=0.80) than the bowmen (mean 0.04, s=0.06 litres, P=0.015, [Formula: see text]=0.44) in double-canoes. Significant morphological asymmetry was found also in kayakers but the effect of paddle grip was not substantial. The use of segmental impedance analysis may be a suitable diagnostic tool for assessing morphological changes, which can be related to paddling training. Likewise muscular asymmetry is associated with injury risk; the evaluation of morphological changes during the training process may be considered by sport trainers and physical therapists.

  6. Relation between hand grip strength, respiratory muscle strength and spirometric measures in male nursing home residents.

    Science.gov (United States)

    Bahat, Gulistan; Tufan, Asli; Ozkaya, Hilal; Tufan, Fatih; Akpinar, Timur Selçuk; Akin, Sibel; Bahat, Zumrut; Kaya, Zuleyha; Kiyan, Esen; Erten, Nilgün; Karan, Mehmet Akif

    2014-09-01

    Adverse-outcomes related to sarcopenia are mostly mentioned as physical disability. As the other skeletal muscles, respiratory muscles may also be affected by sarcopenia. Respiratory muscle strength is known to affect pulmonary functions. Therefore, we aimed to investigate the relations between extremity muscle strength, respiratory muscle strengths and spirometric measures in a group of male nursing home residents. Among a total of 104 male residents, residents with obstructive measures were excluded and final study population was composed of 62 residents. Mean age was 70.5 ± 6.7 years, body mass index: 27.7 ± 5.3 kg/m2 and dominant hand grip strength: 29.7 ± 6.5 kg. Hand grip strength was positively correlated with maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) (r = 0.35, p strength; among spirometric measures only parameter significantly related to grip strength was peak cough flow (PCF). The association of PCF with grip strength disappeared when MIP alone or "MIP and MEP" were included in the regression analysis. In the latter case, PCF was significantly associated only with MIP. We found peripheric muscle strength be associated with MIP and PCF but not with MEP or any other spirometric parameters. The relation between peripheral muscle strength and PCF was mediated by MIP. Our findings suggest that sarcopenia may affect inspiratory muscle strength earlier or more than the expiratory muscle strength. Sarcopenia may cause decrease in PCF in the elderly, which may stand for some common adverse respiratory complications.

  7. Tension free open inguinal hernia repair using an innovative self gripping semi-resorbable mesh

    Directory of Open Access Journals (Sweden)

    Chastan Philippe

    2006-01-01

    Full Text Available Aims: Inguinal hernia repair according to Lichtenstein technique has become the most common procedure performed by general surgeons. Heavy weight polypropylene meshes have been reported to stimulate inflammatory reaction responsible for mesh shrinkage when scar tissue evolved. Additionally, some concerns remain regarding the relationship between chronic pain and mesh fixation technique. In order to reduce those drawbacks, we have developed a new mesh for anterior tension free inguinal hernia repair which exhibits self-gripping absorbable properties. Materials and Methods: 52 patients (69 hernias were prospectivly operated with this mesh (SOFRADIM-France made of low-weight isoelastic large pores knitted fabric which incorporated resorbable micro hooks that provides self gripping properties to the mesh during the first months post-implantation. The fixation of the mesh onto the tissues is significantly facilitated. The mesh is secured around the cord with a self gripping flap. After complete tissular ingrowth and resorption of the PLA hooks, the low-weight (40 g/m2 polypropylene mesh insures the long term wall reinforcement. Results: Peroperativly, no complication was reported, the mesh was easy to handle and to fix. Discharge was obtained at Day 1. No perioperative complication occurred, return to daily activities was obtained at Day 5.5. At one month, no neurological pain or other complications were described. Conclusions: Based on the first results of this clinical study, this unique concept of low density self gripping mesh should allows an efficient treatment of inguinal hernia. It should reduce postoperative complications and the extent of required suture fixation, making the procedure more reproducible

  8. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

    NARCIS (Netherlands)

    Smidt, N.; Windt, A. van der; Assendelft, W.J.; Mourits, A.J.; Devillé, W.L.; Winter, F. de; Bouter, L.M.

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of

  9. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis

    NARCIS (Netherlands)

    Smidt, N; van der Windt, DA; Assendelft, WJ; Mourits, AJ; Deville, WL; de Winter, AF; Bouter, LM

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of compl

  10. Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

    NARCIS (Netherlands)

    Smidt, N.; Windt, A. van der; Assendelft, W.J.; Mourits, A.J.; Devillé, W.L.; Winter, F. de; Bouter, L.M.

    2002-01-01

    Objective: To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. Design: Two physiotherapists assessed independently, and in randomized order, the severity of compl

  11. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment

    DEFF Research Database (Denmark)

    Filteau, Suzanne; PrayGod, G; Woodd, Susannah L

    2017-01-01

    involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index requiring ART. The relationship of grip strength to nutritional, infectious and demographic factors was assessed by multivariable linear regression at referral...

  12. Tsunami Focusing and Leading Amplitude

    Science.gov (United States)

    Kanoglu, U.

    2016-12-01

    Tsunamis transform substantially through spatial and temporal spreading from their source region. This substantial spreading might result unique maximum tsunami wave heights which might be attributed to the source configuration, directivity, the waveguide structures of mid-ocean ridges and continental shelves, focusing and defocusing through submarine seamounts, random focusing due to small changes in bathymetry, dispersion, and, most likely, combination of some of these effects. In terms of the maximum tsunami wave height, after Okal and Synolakis (2016 Geophys. J. Int. 204, 719-735), it is clear that dispersion would be one of the reasons to drive the leading wave amplitude in a tsunami wave train. Okal and Synolakis (2016), referring to this phenomenon as sequencing -later waves in the train becoming higher than the leading one, considered Hammack's (1972, Ph.D. Dissertation, Calif. Inst. Tech., 261 pp) formalism, in addition to LeMéhauté and Wang's (1995 Water waves generated by underwater explosion, World Scientific, 367 pp), to evaluate linear dispersive tsunami propagation from a circular plug uplifted on an ocean of constant depth. They identified transition distance, as the second wave being larger, performing parametric study for the radius of the plug and the depth of the ocean. Here, we extend Okal and Synolakis' (2016) analysis to an initial wave field with a finite crest length and, in addition, to a most common tsunami initial wave form of N-wave (Tadepalli and Synolakis, 1994 Proc. R. Soc. A: Math. Phys. Eng. Sci. 445, 99-112). First, we investigate the focusing feature in the leading-depression side, which enhance tsunami wave height as presented by Kanoglu et al. (2013 Proc. R. Soc. A: Math. Phys. Eng. Sci. 469, 20130015). We then discuss the results in terms of leading wave amplitude presenting a parametric study and identify a simple relation for the transition distance. The solution presented here could be used to better analyze dispersive

  13. Flash Detection Efficiencies of Long Range Lightning Detection Networks During GRIP

    Science.gov (United States)

    Mach, Douglas M.; Bateman, Monte G.; Blakeslee, Richard J.

    2012-01-01

    We flew our Lightning Instrument Package (LIP) on the NASA Global Hawk as a part of the Genesis and Rapid Intensification Processes (GRIP) field program. The GRIP program was a NASA Earth science field experiment during the months of August and September, 2010. During the program, the LIP detected lighting from 48 of the 213 of the storms overflown by the Global Hawk. The time and location of tagged LIP flashes can be used as a "ground truth" dataset for checking the detection efficiency of the various long or extended range ground-based lightning detection systems available during the GRIP program. The systems analyzed included Vaisala Long Range (LR), Vaisala GLD360, the World Wide Lightning Location Network (WWLLN), and the Earth Networks Total Lightning Network (ENTLN). The long term goal of our research is to help understand the advantages and limitations of these systems so that we can utilize them for both proxy data applications and cross sensor validation of the GOES-R Geostationary Lightning Mapper (GLM) sensor when it is launched in the 2015 timeframe.

  14. Cortical activation during power grip task with pneumatic pressure gauge: an fMRI study

    Science.gov (United States)

    Mohamad, M.; Mardan, N. H.; Ismail, S. S.

    2017-05-01

    Aging is associated with a decline in cognitive and motor function. But, the relationships with motor performance are less well understood. In this study, functional magnetic resonance imaging (fMRI) was used to assess cortical activation in older adults. This study employed power grip task that utilised block paradigm consisted of alternate 30s rest and active. A visual cue was used to pace the hand grip movement that clenched a cylindrical rubber bulb connected with pressure pneumatic gauge that measure the pressure (Psi). The objective of this study is determined the brain areas activated during motor task and the correlation between percentage signal change of each motor area (BA 4 and 6) and hand grip pressure. Result showed there was a significant difference in mean percentage signal change in BA 4 and BA 6 in both hemispheres and negative correlation obtained in BA 4 and BA 6. These results indicate that a reduced ability in the motor networks contribute to age-related decline in motor performance.

  15. On the Effect of Different Grips of Handsets on Data Rate in the Measured Channels

    Directory of Open Access Journals (Sweden)

    Maryam Rahimi

    2015-01-01

    Full Text Available The investigation on the achieved data rate of the cellular system considering different grips of handsets at different frequencies using measurement results of the measurement campaign—which was carried out in the city of Aalborg—is presented in this paper. The achieved data rate of the multiple-input single-output (MISO interference channel is investigated. A typical propagation environment using two BSs and four handsets, like smart phones, held by four to eight different users was designed and multiple-input multiple-output (MIMO channels in different scenarios were measured. In this paper, two BSs and two handsets at each measurement time are considered. The impact of the different parameters like correlation, different grips of handsets, and different long term evolution (LTE frequency bands on the achieved data rate is investigated for different measurements. It could be concluded that the variations in the values of data rate are weakly associated with the different grips of handsets but more correlated with different frequencies.

  16. Design and implementation of GRIP: a computerized glucose control system at a surgical intensive care unit

    Directory of Open Access Journals (Sweden)

    Zijlstra Felix

    2005-12-01

    Full Text Available Abstract Background Tight glucose control by intensive insulin therapy has become a key part of critical care and is an important field of study in acute coronary care. A balance has to be found between frequency of measurements and the risk of hypoglycemia. Current nurse-driven protocols are paper-based and, therefore, rely on simple rules. For safety and efficiency a computer decision support system that employs complex logic may be superior to paper protocols. Methods We designed and implemented GRIP, a stand-alone Java computer program. Our implementation of GRIP will be released as free software. Blood glucose values measured by a point-of-care analyzer were automatically retrieved from the central laboratory database. Additional clinical information was asked from the nurse and the program subsequently advised a new insulin pump rate and glucose sampling interval. Results Implementation of the computer program was uneventful and successful. GRIP treated 179 patients for a total of 957 patient-days. Severe hypoglycemia ( Conclusion A computer driven protocol is a safe and effective means of glucose control at a surgical ICU. Future improvements in the recommendation algorithm may further improve safety and efficiency.

  17. Nutritional status is the major factor affecting grip strength of African HIV patients before and during antiretroviral treatment.

    Science.gov (United States)

    Filteau, S; PrayGod, G; Woodd, S L; Friis, H; Heimburger, D C; Koethe, J R; Kelly, P; Kasonka, L; Rehman, A M

    2017-10-01

    Low grip strength is a marker of frailty and a risk factor for mortality among HIV patients and other populations. We investigated factors associated with grip strength in malnourished HIV patients at referral to ART, and at 12 weeks and 2-3 years after starting ART. The study involved HIV-infected Zambian and Tanzanian participants recruited to the NUSTART trial when malnourished (body mass index <18.5 kg/m(2) ) and requiring ART. The relationship of grip strength to nutritional, infectious and demographic factors was assessed by multivariable linear regression at referral for ART (n = 1742) and after 12 weeks (n = 778) and 2-3 years of ART (n = 273). In analyses controlled only for sex, age and height, most nutrition and infection-related variables were associated with grip strength. However, in multivariable analyses, consistent associations were seen for fat-free mass index, mid-upper arm circumference, haemoglobin and systolic blood pressure, and a variable association with fat mass index in men. C-reactive protein and CD4 count had limited independent effects on grip strength, while receiving tuberculosis treatment was associated with weaker grip strength. In this population of originally malnourished HIV patients, poor grip strength was more strongly and independently associated with nutritional than with infection and inflammation variables. Programmes to improve health and survival of HIV patients should incorporate nutritional assessment and management and could use grip strength as a functional indicator of improving nutrition. © 2017 John Wiley & Sons Ltd.

  18. Dynamic Nonlinear Focal Shift in Amplitude Modulated Moderately Focused Acoustic Beams

    CERN Document Server

    Jiménez, Noé; González-Salido, Nuria

    2016-01-01

    The phenomenon of the displacement of the position of the pressure, intensity and acoustic radiation force maxima along the axis of focused acoustic beams under increasing driving amplitudes (nonlinear focal shift) is studied for the case of a moderately focused beam excited with continuous and 25 kHz amplitude modulated signals, both in water and tissue. We prove that in amplitude modulated beams the linear and nonlinear propagation effects coexist in a semi-period of modulation, giving place to a complex dynamic behaviour, where the singular points of the beam (peak pressure, rarefaction, intensity and acoustic radiation force) locate at different points on axis as a function of time. These entire phenomena are explained in terms of harmonic generation and absorption during the propagation in a lossy nonlinear medium both, for a continuous and an amplitude modulated beam. One of the possible applications of the acoustic radiation force displacement is the generation of shear waves at different locations by ...

  19. Quantum Amplitude Amplification and Estimation

    CERN Document Server

    Brassard, G; Mosca, M; Tapp, A; Brassard, Gilles; Hoyer, Peter; Mosca, Michele; Tapp, Alain

    2000-01-01

    Consider a Boolean function $\\chi: X \\to \\{0,1\\}$ that partitions set $X$ between its good and bad elements, where $x$ is good if $\\chi(x)=1$ and bad otherwise. Consider also a quantum algorithm $\\mathcal A$ such that $A \\ket{0} = \\sum_{x\\in X} \\alpha_x \\ket{x}$ is a quantum superposition of the elements of $X$, and let $a$ denote the probability that a good element is produced if $A \\ket{0}$ is measured. If we repeat the process of running $A$, measuring the output, and using $\\chi$ to check the validity of the result, we shall expect to repeat $1/a$ times on the average before a solution is found. *Amplitude amplification* is a process that allows to find a good $x$ after an expected number of applications of $A$ and its inverse which is proportional to $1/\\sqrt{a}$, assuming algorithm $A$ makes no measurements. This is a generalization of Grover's searching algorithm in which $A$ was restricted to producing an equal superposition of all members of $X$ and we had a promise that a single $x$ existed such tha...

  20. Stress examination of flexor tendon pulley rupture in the crimp grip position: a 1.5-Tesla MRI cadaver study

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, Thomas; Janka, Rolf [University of Erlangen-Nuremberg, Department of Radiology, Erlangen (Germany); Fries, Simon [Cantonal Hospital Lucerne, Orthopaedic Department, Wolhusen (Switzerland); Schweizer, Andreas [University of Zurich, Department of Orthopaedics, Balgrist, Zurich (Switzerland); Schoeffl, Isabelle [Klinikum Bamberg, Department of Pediatrics, Bamberg (Germany); Bongartz, Georg [University Basel, Department of Radiology, Basel (Switzerland)

    2015-01-15

    The objectives of this study were the evaluation of flexor tendon pulley rupture of the fingers in the crimp grip position using magnetic resonance imaging (MRI) and the comparison of the results with MRI in the neutral position in a cadaver study. MRI in the crimp grip position and in the neutral position was performed in 21 cadaver fingers with artificially created flexor tendon pulley tears (combined pulley rupture, n = 14; single pulley rupture, n = 7). Measurement of the distance between the tendon and bone was performed. Images were evaluated by two readers, first independently and in cases of discrepancy in consensus. Sensitivity and specificity for detecting combined pulley ruptures were calculated. Tendon bone distances were significantly higher in the crimp grip position than in the neutral position. Sensitivity and specificity for detecting combined pulley rupture were 92.86 % and 100 % respectively in the crimp grip position and 78.57 % and 85.71 % respectively in the neutral position. Kappa values for interobserver reliability were 0.87 in the crimp grip position and 0.59 in the neutral position. MRI examination in the crimp grip position results in higher tendon bone distances by subjecting the pulleys to a higher strain, which facilitates image evaluation with higher interobserver reliability, higher sensitivity, and higher specificity for combined pulley rupture compared with examination in the neutral position. (orig.)

  1. Effects of oncoming target velocities on rapid force production and accuracy of force production intensity and timing.

    Science.gov (United States)

    Ohta, Yoichi

    2016-12-12

    The present study aimed to clarify the effects of oncoming target velocities on the ability of rapid force production and accuracy and variability of simultaneous control of both force production intensity and timing. Twenty male participants (age: 21.0 ± 1.4 years) performed rapid gripping with a handgrip dynamometer to coincide with the arrival of an oncoming target by using a horizontal electronic trackway. The oncoming target velocities were 4, 8, and 12 m · s(-1), which were randomly produced. The grip force required was 30% of the maximal voluntary contraction. Although the peak force (Pf) and rate of force development (RFD) increased with increasing target velocity, the value of the RFD to Pf ratio was constant across the 3 target velocities. The accuracy of both force production intensity and timing decreased at higher target velocities. Moreover, the intrapersonal variability in temporal parameters was lower in the fast target velocity condition, but constant variability in 3 target velocities was observed in force intensity parameters. These results suggest that oncoming target velocity does not intrinsically affect the ability for rapid force production. However, the oncoming target velocity affects accuracy and variability of force production intensity and timing during rapid force production.

  2. Roll dynamics of a ship sailing in large amplitude head waves

    NARCIS (Netherlands)

    Daalen, E.F.G.; Gunsing, M.; Grasman, J.; Remmert, J.

    2014-01-01

    Some ship types may show significant rolling when sailing in large-amplitude (near) head waves. The dynamics of the ship are such that the roll motion is affected by the elevation of the encountering waves. If the natural roll period (without forcing) is about half the period of the forcing by the w

  3. Force feedback reinforces muscle synergies in insect legs.

    Science.gov (United States)

    Zill, Sasha N; Chaudhry, Sumaiya; Büschges, Ansgar; Schmitz, Josef

    2015-11-01

    The nervous system solves complex biomechanical problems by activating muscles in modular, synergist groups. We have studied how force feedback in substrate grip is integrated with effects of sense organs that monitor support and propulsion in insects. Campaniform sensilla are mechanoreceptors that encode forces as cuticular strains. We tested the hypothesis that integration of force feedback from receptors of different leg segments during grip occurs through activation of specific muscle synergies. We characterized the effects of campaniform sensilla of the feet (tarsi) and proximal segments (trochanter and femur) on activities of leg muscles in stick insects and cockroaches. In both species, mechanical stimulation of tarsal sensilla activated the leg muscle that generates substrate grip (retractor unguis), as well as proximal leg muscles that produce inward pull (tibial flexor) and support/propulsion (trochanteral depressor). Stimulation of campaniform sensilla on proximal leg segments activated the same synergistic group of muscles. In stick insects, the effects of proximal receptors on distal leg muscles changed and were greatly enhanced when animals made active searching movements. In insects, the task-specific reinforcement of muscle synergies can ensure that substrate adhesion is rapidly established after substrate contact to provide a stable point for force generation.

  4. A mechanistic ultrasonic vibration amplitude model during rotary ultrasonic machining of CFRP composites.

    Science.gov (United States)

    Ning, Fuda; Wang, Hui; Cong, Weilong; Fernando, P K S C

    2017-04-01

    Rotary ultrasonic machining (RUM) has been investigated in machining of brittle, ductile, as well as composite materials. Ultrasonic vibration amplitude, as one of the most important input variables, affects almost all the output variables in RUM. Numerous investigations on measuring ultrasonic vibration amplitude without RUM machining have been reported. In recent years, ultrasonic vibration amplitude measurement with RUM of ductile materials has been investigated. It is found that the ultrasonic vibration amplitude with RUM was different from that without RUM under the same input variables. RUM is primarily used in machining of brittle materials through brittle fracture removal. With this reason, the method for measuring ultrasonic vibration amplitude in RUM of ductile materials is not feasible for measuring that in RUM of brittle materials. However, there are no reported methods for measuring ultrasonic vibration amplitude in RUM of brittle materials. In this study, ultrasonic vibration amplitude in RUM of brittle materials is investigated by establishing a mechanistic amplitude model through cutting force. Pilot experiments are conducted to validate the calculation model. The results show that there are no significant differences between amplitude values calculated by model and those obtained from experimental investigations. The model can provide a relationship between ultrasonic vibration amplitude and input variables, which is a foundation for building models to predict other output variables in RUM.

  5. Force and motion

    CERN Document Server

    Robertson, William C

    2002-01-01

    Intimidated by inertia? Frightened by forces? Mystified by Newton s law of motion? You re not alone and help is at hand. The stop Faking It! Series is perfect for science teachers, home-schoolers, parents wanting to help with homework all of you who need a jargon-free way to learn the background for teaching middle school physical science with confidence. With Bill Roberton as your friendly, able but somewhat irreverent guide, you will discover you CAN come to grips with the basics of force and motion. Combining easy-to-understand explanations with activities using commonly found equipment, this book will lead you through Newton s laws to the physics of space travel. The book is as entertaining as it is informative. Best of all, the author understands the needs of adults who want concrete examples, hands-on activities, clear language, diagrams and yes, a certain amount of empathy. Ideas For Use Newton's laws, and all of the other motion principles presented in this book, do a good job of helping us to underst...

  6. Discontinuities of multi-Regge amplitudes

    CERN Document Server

    Fadin, V S

    2014-01-01

    In the BFKL approach, discontinuities of multiple production amplitudes in invariant masses of produced particles are discussed. It turns out that they are in evident contradiction with the BDS ansatz for $n$-gluon amplitudes in the planar $N$=4 SYM at $n\\ge 6$. An explicit expression for the NLO discontinuity of the two-to-four amplitude in the invariant mass of two produced gluons is is presented.

  7. On the singularities of massive superstring amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Foda, O.

    1987-06-04

    Superstring one-loop amplitudes with massive external states are shown to be in general ill-defined due to internal on-shell propagators. However, we argue that since any massive string state (in the uncompactified theory) has a finite lifetime to decay into massless particles, such amplitudes are not terms in the perturbative expansion of physical S-matrix elements: These can be defined only with massless external states. Consistent massive amplitudes repuire an off-shell formalism.

  8. DVCS amplitude with kinematical twist-3 terms

    CERN Document Server

    Radyushkin, A V

    2000-01-01

    We compute the amplitude of deeply virtual Compton scattering (DVCS) using the calculus of QCD string operators in coordinate representation. To restore the electromagnetic gauge invariance (transversality) of the twist-2 amplitude we include the operators of twist-3 which appear as total derivatives of twist-2 operators. Our results are equivalent to a Wandzura-Wilczek approximation for twist-3 skewed parton distributions. We find that this approximation gives a finite result for the amplitude of a longitudinally polarized virtual photon, while the amplitude for transverse polarization is divergent, i.e., factorization breaks down in this term.

  9. Scattering Amplitudes via Algebraic Geometry Methods

    DEFF Research Database (Denmark)

    Søgaard, Mads

    This thesis describes recent progress in the understanding of the mathematical structure of scattering amplitudes in quantum field theory. The primary purpose is to develop an enhanced analytic framework for computing multiloop scattering amplitudes in generic gauge theories including QCD without...... Feynman diagrams. The study of multiloop scattering amplitudes is crucial for the new era of precision phenomenology at the Large Hadron Collider (LHC) at CERN. Loop-level scattering amplitudes can be reduced to a basis of linearly independent integrals whose coefficients are extracted from generalized...

  10. Effects of transcranial direct current stimulation on the control of finger force during dexterous manipulation in healthy older adults.

    Directory of Open Access Journals (Sweden)

    Pranav J Parikh

    Full Text Available The contribution of poor finger force control to age-related decline in manual dexterity is above and beyond ubiquitous behavioral slowing. Altered control of the finger forces can impart unwanted torque on the object affecting its orientation, thus impairing manual performance. Anodal transcranial direct current stimulation (tDCS over primary motor cortex (M1 has been shown to improve the performance speed on manual tasks in older adults. However, the effects of anodal tDCS over M1 on the finger force control during object manipulation in older adults remain to be fully explored. Here we determined the effects of anodal tDCS over M1 on the control of grip force in older adults while they manipulated an object with an uncertain mechanical property. Eight healthy older adults were instructed to grip and lift an object whose contact surfaces were unexpectedly made more or less slippery across trials using acetate and sandpaper surfaces, respectively. Subjects performed this task before and after receiving anodal or sham tDCS over M1 on two separate sessions using a cross-over design. We found that older adults used significantly lower grip force following anodal tDCS compared to sham tDCS. Friction measured at the finger-object interface remained invariant after anodal and sham tDCS. These findings suggest that anodal tDCS over M1 improved the control of grip force during object manipulation in healthy older adults. Although the cortical networks for representing objects and manipulative actions are complex, the reduction in grip force following anodal tDCS over M1 might be due to a cortical excitation yielding improved processing of object-specific sensory information and its integration with the motor commands for production of manipulative forces. Our findings indicate that tDCS has a potential to improve the control of finger force during dexterous manipulation in older adults.

  11. Multisensory interaction in vibrotactile detection and discrimination of amplitude modulation

    DEFF Research Database (Denmark)

    Teodorescu, Kinneret; Bouchigny, Sylvain; Hoffmann, Pablo F.

    2011-01-01

    Perception of vibration during drilling demands integration of haptic and auditory information with force information. In this study we explored the ability to detect and discriminate changes in vibrotactile stimuli amplitude based either on purely haptic feedback or together with congruent...... synthesized auditory cues in groups of naive subjects and expert surgeons. Our results point toward the complex influence of multimodal experience during vibration perception. First, in naive subjects, we showed that detection and discrimination of amplitude change in complex vibro-tactile stimulus...... is selectively sensitive to combination of modality and previous experience. In the domain of discrimination, our results suggest that bi-modal performance is always better than uni-modal performance regardless of order of experience. Second, experiments with expert surgeons revealed that expertise in complex...

  12. Analytical approximations for stick-slip vibration amplitudes

    DEFF Research Database (Denmark)

    Thomsen, Jon Juel; Fidlin, A.

    2003-01-01

    The classical "mass-on-moving-belt" model for describing friction-induced vibrations is considered, with a friction law describing friction forces that first decreases and then increases smoothly with relative interface speed. Approximate analytical expressions are derived for the conditions......, the amplitudes, and the base frequencies of friction-induced stick¿slip and pure-slip oscillations. For stick¿slip oscillations, this is accomplished by using perturbation analysis for the finite time interval of the stick phase, which is linked to the subsequent slip phase through conditions of continuity...... and periodicity. The results are illustrated and tested by time-series, phase plots and amplitude response diagrams, which compare very favorably with results obtained by numerical simulation of the equation of motion, as long as the difference in static and kinetic friction is not too large....

  13. REDUCED HAND GRIP STRENGTH IN OVERWEIGHT AND OBESE CHRONIC HEPATITIS C PATIENTS.

    Science.gov (United States)

    Bruch, Juliana Paula; Álvares-DA-Silva, Mário Reis; Alves, Bruna Cherubini; Dall'alba, Valesca

    2016-01-01

    Hepatitis C is a liver disease that causes significant changes in metabolism, and also has an impact on nutritional status. To evaluate the nutritional status and cardiovascular risk in patients with chronic hepatitis C. This cross-sectional study investigated 58 patients with chronic hepatitis C, non-cirrhotic and were not under active pharmacological treatment. Patients with significant alcohol consumption (greater than 10 g ethanol/day) were excluded. Patients underwent nutritional assessment through anthropometric measurements and functional assessment using hand grip strength by dynamometry. The physical activity was assessed using the International Physical Activity Questionnaire. Patients also underwent clinical and laboratory evaluation. Cardiovascular risk was calculated by the Framingham score. The mean age of patients was 51.6±9.7 years, 55.2% were female, and 79.3% had genotype 1. The most prevalent degree of fibrosis was F1 (37.9%) followed by F2 (27.6%) and F3 (1.7%). The prevalence of overweight/obesity considering the body mass index was 70.7%. However, 57.7% of men and 68.8% of women were considered malnourished according to hand grip strength. These patients also had waist circumference (93.5±10.7 cm) and neck circumference (37.0±3.6 cm) high. Almost 60% of patients were considered sedentary or irregularly active. In relation to cardiovascular risk, 50% of patients had high risk of suffering a cardiovascular event within 10 years. Although most patients with hepatitis C presented overweight, associated with high cardiovascular risk, they also have reduced functional capacity, indicative of protein-caloric commitment. Therefore, body mass index can not be considered the only method of assessment for nutritional diagnosis of patients with liver disease. Adopting methods such as hand grip strength can be important for a better understanding of nutritional status of these patients.

  14. IMPACT OF COMBINING MIRROR THERAPY AND HABIT ON HAND GRIP STRENGTH IN CHILDREN WITH HEMIPARESIS

    OpenAIRE

    Asmaa A. Abo Nour; Saleh, Muhammad G.; Emam H. Elnagmy

    2016-01-01

    Background: hemiparetic children usually tend to avoid the use of their impaired arm and are remarkably tend to perform inherently bimanual tasks of daily living with the less impaired arm only rather than with both arms. In fact, these children actually may have never learned to use their impaired arm for certain motor tasks or may only use it in the simplest manner, so the purpose of the study was to determine the impact of combining HABIT and mirror therapy on hand grip in hemiparetic chil...

  15. BCFW construction of the Veneziano amplitude

    Energy Technology Data Exchange (ETDEWEB)

    Fotopoulos, Angelos, E-mail: foto@to.infn.it [Dipartimento di Fisica Teorica dell Universita di Torino and INFN Sezione di Torino, via P. Giuria 1, I-10125 Torino (Italy)

    2011-06-10

    In this paper we demonstrate how one can compute the Veneziano amplitude for bosonic string theory using the Britto-Cachazo-Feng-Witten method. We use an educated ansatz for the cubic amplitude of two tachyons and an arbitrary level string state.

  16. BCFW construction of the Veneziano amplitude

    Science.gov (United States)

    Fotopoulos, Angelos

    2011-06-01

    In this paper we demonstrate how one can compute the Veneziano amplitude for bosonic string theory using the Britto-Cachazo-Feng-Witten method. We use an educated ansatz for the cubic amplitude of two tachyons and an arbitrary level string state.

  17. Interlimb coupling strength scales with movement amplitude.

    Science.gov (United States)

    Peper, C Lieke E; de Boer, Betteco J; de Poel, Harjo J; Beek, Peter J

    2008-05-23

    The relation between movement amplitude and the strength of interlimb interactions was examined by comparing bimanual performance at different amplitude ratios (1:2, 1:1, and 2:1). For conditions with unequal amplitudes, the arm moving at the smaller amplitude was predicted to be more strongly affected by the contralateral arm than vice versa. This prediction was based on neurophysiological considerations and the HKB model of coupled oscillators. Participants performed rhythmic bimanual forearm movements at prescribed amplitude relations. After a brief mechanical perturbation of one arm, the relaxation process back to the initial coordination pattern was examined. This analysis focused on phase adaptations in the unperturbed arm, as these reflect the degree to which the movements of this arm were affected by the coupling influences stemming from the contralateral (perturbed) arm. The thus obtained index of coupling (IC) reflected the relative contribution of the unperturbed arm to the relaxation process. As predicted IC was larger when the perturbed arm moved at a larger amplitude than did the unperturbed arm, indicating that coupling strength scaled with movement amplitude. This result was discussed in relation to previous research regarding sources of asymmetry in coupling strength and the effects of amplitude disparity on interlimb coordination.

  18. Robust seismic images amplitude recovery using curvelets

    NARCIS (Netherlands)

    Moghaddam, Peyman P.; Herrmann, Felix J.; Stolk, C.C.

    2007-01-01

    In this paper, we recover the amplitude of a seismic image by approximating the normal (demigration-migration) operator. In this approximation, we make use of the property that curvelets remain invariant under the action of the normal operator. We propose a seismic amplitude recovery method that

  19. Off-shell amplitudes and Grassmannians

    Science.gov (United States)

    Bork, L. V.; Onishchenko, A. I.

    2017-09-01

    The Grassmannian representation for gauge-invariant amplitudes for arbitrary number of legs with one of them being off-shell is derived for the case of N = 4 SYM. The obtained formula are successfully checked against known BCFW results for MHV n , NMHV4 and NMHV5 amplitudes.

  20. On the singularities of massive superstring amplitudes

    NARCIS (Netherlands)

    Foda, O.

    1987-01-01

    Superstring one-loop amplitudes with massive external states are shown to be in general ill-defined due to internal on-shell propagators. However, we argue that since any massive string state (in the uncompactified theory) has a finite lifetime to decay into massless particles, such amplitudes are n

  1. On the singularities of massive superstring amplitudes

    NARCIS (Netherlands)

    Foda, O.

    1987-01-01

    Superstring one-loop amplitudes with massive external states are shown to be in general ill-defined due to internal on-shell propagators. However, we argue that since any massive string state (in the uncompactified theory) has a finite lifetime to decay into massless particles, such amplitudes are

  2. Effect of three different grip angles on physical parameters during laboratory test in handcycling in able-bodied participants

    Directory of Open Access Journals (Sweden)

    Thomas eAbel

    2015-11-01

    Full Text Available Introduction: Handcycling is a relatively new wheelchair sport that has gained increased popularity for people with lower limb disabilities. The aim of this study was to examine the effect of three different grip positions on physical parameters during handcycling in a laboratory setting.Methods: Twenty one able-bodied participants performed three maximum incremental handcycling tests until exhaustion, each with a different grip angle. The angle between the grip and the crank was randomly set at 90° (horizontal, 0° (vertical or 10° (diagonal. The initial load was 20 W and increased by 20 W each five minutes. In addition, participants performed a 20 s maximum effort.Results: The relative peak functional performance (W/kg, peak heart rate (bpm, associated lactate concentrations (mmol/l and peak oxygen uptake per kilogram body weight (ml.min-1.kg-1 for the different grip positions during the stage test were: (a Horizontal: 1.43 ± 0.21 W/kg, 170.14 ± 12.81 bpm, 9.54 ± 1.93 mmol/l, 30.86 ± 4.57 ml/kg; (b Vertical: 1.38 ± 0.20 W/kg, 171.81 ± 13.87 bpm, 9.91 ± 2.29 mmol/l, 29.75 ± 5.13 ml/kg; (c Diagonal: 1.40 ± 0.22 W/kg, 169.19 ± 13.31 bpm, 9.34 ± 2.36 mmol/l, 29.39 ± 4.70 ml/kg. Statistically significant (p <0.05 differences could only be found for lactate concentration between the vertical grip position and the other grips during submaximal handcycling. Conclusion: The orientation of three different grip angles made no difference to the peak load achieved during an incremental handcycling test and a 20 second maximum effort. At submaximal load, higher lactate concentrations were found when the vertical grip position was used, suggesting that this position may be less efficient than the alternative diagonal or horizontal grip positions.

  3. 可调式握力高枝剪设计及分析%Design and Analysis for Grip Type and Adjustable Lopper

    Institute of Scientific and Technical Information of China (English)

    钱稷; 邸葆; 王鹏飞; 陈海江

    2015-01-01

    可调式握力高枝剪的设计包括外观参数的确定和刀具的设计。根据大宗果树的生长状况确定高枝剪各关键部件结构及参数;根据高枝剪在果园作业受到剪枝过程中刀具剪断和夹持枝条所需力的大小进行刀具的设计。通过在Inventor 软件中构建可调式手握高枝剪三维模型,利用 AIP 中的有限元功能对模型进行分析,得出果园工作环境下高枝剪的安全系数和变形量。果园作业试验结果表明:在该设计参数下,高枝剪性能可靠、使用灵活。%According to the orchard pruning , picking jobs in the working environment conditions ( such as cutting and clamping force required for branches , and so on ) and growth of fruit trees ( such as line spacing and height of fruit trees , and so on ) , choose the right material and appearance of the tree pruner parameters .Building three -dimensional model of grip type and adjustable lopper in software of Inventor .Using technology of ANSYS in the AIP for finite element analy-sis of cutter belong to grip type and adjustable lopper , getting safety coefficients of the lopper .Having experiments in or-chards and testing the date .Proved that the lopper in this design parameter is reliable and flexible in use .

  4. The Lorentzian proper vertex amplitude: Asymptotics

    CERN Document Server

    Engle, Jonathan; Zipfel, Antonia

    2015-01-01

    In previous work, the Lorentzian proper vertex amplitude for a spin-foam model of quantum gravity was derived. In the present work, the asymptotics of this amplitude are studied in the semi-classical limit. The starting point of the analysis is an expression for the amplitude as an action integral with action differing from that in the EPRL case by an extra `projector' term which scales linearly with spins only in the asymptotic limit. New tools are introduced to generalize stationary phase methods to this case. For the case of boundary data which can be glued to a non-degenerate Lorentzian 4-simplex, the asymptotic limit of the amplitude is shown to equal the single Feynman term, showing that the extra term in the asymptotics of the EPRL amplitude has been eliminated.

  5. Amplitude image processing by diffractive optics.

    Science.gov (United States)

    Cagigal, Manuel P; Valle, Pedro J; Canales, V F

    2016-02-22

    In contrast to the standard digital image processing, which operates over the detected image intensity, we propose to perform amplitude image processing. Amplitude processing, like low pass or high pass filtering, is carried out using diffractive optics elements (DOE) since it allows to operate over the field complex amplitude before it has been detected. We show the procedure for designing the DOE that corresponds to each operation. Furthermore, we accomplish an analysis of amplitude image processing performances. In particular, a DOE Laplacian filter is applied to simulated astronomical images for detecting two stars one Airy ring apart. We also check by numerical simulations that the use of a Laplacian amplitude filter produces less noisy images than the standard digital image processing.

  6. A novel mechanism of hippocampal LTD involving muscarinic receptor-triggered interactions between AMPARs, GRIP and liprin-α

    Directory of Open Access Journals (Sweden)

    Dickinson Bryony A

    2009-06-01

    Full Text Available Abstract Background Long-term depression (LTD in the hippocampus can be induced by activation of different types of G-protein coupled receptors, in particular metabotropic glutamate receptors (mGluRs and muscarinic acethycholine receptors (mAChRs. Since mGluRs and mAChRs activate the same G-proteins and isoforms of phospholipase C (PLC, it would be expected that these two forms of LTD utilise the same molecular mechanisms. However, we find a distinct mechanism of LTD involving GRIP and liprin-α. Results Whilst both forms of LTD require activation of tyrosine phosphatases and involve internalisation of AMPARs, they use different molecular interactions. Specifically, mAChR-LTD, but not mGluR-LTD, is blocked by peptides that inhibit the binding of GRIP to the AMPA receptor subunit GluA2 and the binding of GRIP to liprin-α. Thus, different receptors that utilise the same G-proteins can regulate AMPAR trafficking and synaptic efficacy via distinct molecular mechanisms. Conclusion Our results suggest that mAChR-LTD selectively involves interactions between GRIP and liprin-α. These data indicate a novel mechanism of synaptic plasticity in which activation of M1 receptors results in AMPAR endocytosis, via a mechanism involving interactions between GluA2, GRIP and liprin-α.

  7. Amplitude control of the track-induced self-excited vibration for a maglev system.

    Science.gov (United States)

    Zhou, Danfeng; Li, Jie; Zhang, Kun

    2014-09-01

    The Electromagnet Suspension (EMS) maglev train uses controlled electromagnetic forces to achieve suspension, and self-excited vibration may occur due to the flexibility of the track. In this article, the harmonic balance method is applied to investigate the amplitude of the self-excited vibration, and it is found that the amplitude of the vibration depends on the voltage of the power supplier. Based on this observation, a vibration amplitude control method, which controls the amplitude of the vibration by adjusting the voltage of the power supplier, is proposed to attenuate the vibration. A PI controller is designed to control the amplitude of the vibration at a given level. The effectiveness of this method shows a good prospect for its application to commercial maglev systems.

  8. Effect of object width on muscle and joint forces during thumb-index finger grasping.

    Science.gov (United States)

    Vigouroux, Laurent; Domalain, Mathieu; Berton, Eric

    2011-08-01

    The objective of this study was to identify the impact of modifying the object width on muscle and joint forces while gripping objects. The experimental protocol consisted to maintain horizontally five objects of different widths (3.5, 4.5, 5.5, 6.5, and 7.5 cm) with a thumb-index finger grip. Subjects were required to grasp spontaneously the object without any instruction regarding the grip force (GF) to apply. A biomechanical model of thumb-index finger pinch was developed to estimate muscle and joint forces. This model included electromyography, fingertip force, and kinematics data as inputs. The finger joint postures and the GF varied across the object widths. The estimated muscle forces also varied significantly according to the object width. Interestingly, we observed that the muscle force/GF ratios of major flexor muscles remain particularly stable with respect to the width whereas other muscle ratios differed largely. This may argue for a control strategy in which the actions of flexors were preserved in spite of change in joint postures. The estimated joint forces tended to increase with object width and increased in the distal-proximal sense. Overall, these results are of importance for the ergonomic design of handheld objects and for clinical applications.

  9. GRiP: a computational tool to simulate transcription factor binding in prokaryotes.

    Science.gov (United States)

    Zabet, Nicolae Radu; Adryan, Boris

    2012-05-01

    Transcription factors (TFs) are proteins that regulate gene activity by binding to specific sites on the DNA. Understanding the way these molecules locate their target site is of great importance in understanding gene regulation. We developed a comprehensive computational model of this process and estimated the model parameters in (N.R.Zabet and B.Adryan, submitted for publication). GRiP (gene regulation in prokaryotes) is a highly versatile implementation of this model and simulates the search process in a computationally efficient way. This program aims to provide researchers in the field with a flexible and highly customizable simulation framework. Its features include representation of DNA sequence, TFs and the interaction between TFs and the DNA (facilitated diffusion mechanism), or between various TFs (cooperative behaviour). The software will record both information on the dynamics associated with the search process (locations of molecules) and also steady-state results (affinity landscape, occupancy-bias and collision hotspots). http://logic.sysbiol.cam.ac.uk/grip, program and source code

  10. Electric Field Measurements During the Genesis and Rapid Intensification Processes (GRIP) Field Program

    Science.gov (United States)

    Bateman, Monte G.; Blakeslee, Richard J.; Mach, Douglas M.

    2010-01-01

    During the Genesis and Rapid Intensification Processes (GRIP) field program, a system of 6 electric field mills was flown on one of NASA's Global Hawk aircraft. We placed several mills on the aircraft to enable us to measure the vector electric field. We created a distributed, ethernet-connected system so that each sensor has its own embedded Linux system, complete with web server. This makes our current generation system fully "sensor web enabled." The Global Hawk has several unique qualities, but relevant to quality storm electric field measurements are high altitude (20 km) and long duration (20-30 hours) flights. There are several aircraft participating in the GRIP program, and coordinated measurements are happening. Lightning and electric field measurements will be used to study the relationships between lightning and other storm characteristics. It has been long understood that lightning can be used as a marker for strong convective activity. Past research and field programs suggest that lightning flash rate may serve as an indicator and precursor for rapid intensification change in tropical cyclones and hurricanes. We have the opportunity to sample hurricanes for many hours at a time and observe intensification (or de-intensification) periods. The electrical properties of hurricanes during such periods are not well known. American

  11. MusicGlove: motivating and quantifying hand movement rehabilitation by using functional grips to play music.

    Science.gov (United States)

    Friedman, Nizan; Chan, Vicky; Zondervan, Danny; Bachman, Mark; Reinkensmeyer, David J

    2011-01-01

    People with stroke typically must perform much of their hand exercise at home without professional assistance as soon as two weeks after the stroke. Without feedback and encouragement, individuals often lose motivation to practice using the affected hand, and this disuse contributes to further declines in hand function. We developed the MusicGlove as a way to facilitate and motivate at home practice of hand movement. This low-cost device uses music as an interactive and motivating medium to guide hand exercise and to quantitatively assess hand movement recovery. It requires the user to practice functional movements, including pincer grip, key-pinch grip, and finger-thumb opposition, by using those movements to play different musical notes, played along to songs displayed by an interactive computer game. We report here the design of the glove and the results of a single-session experiment with 10 participants with chronic stroke. We found that the glove is well suited for use by people with an impairment level quantified by a Box and Blocks score of at least around 7; that the glove can be used to obtain a measure of hand dexterity (% of notes hit) that correlates strongly with the Box and Blocks score; and that the incorporation of music into training significantly improved both objective measures of hand motor performance and self-ratings of motivation for training in the single session.

  12. The administration and interpretation of the rapid exchange grip test: a national survey.

    Science.gov (United States)

    Shechtman, Orit; Goodall, Sara K

    2008-01-01

    The purpose of the present study was to determine if the administration and interpretation of the rapid exchange grip (REG) test vary among hand therapists nationally. The REG is used to determine sincerity of effort of grip strength. There are inconsistencies in the literature regarding the administration and interpretation of the REG, as various studies use different testing protocols and diverse interpretation criteria for what constitutes a sincere effort. As a result, we expected to find a lack of standardization in the administration and interpretation of the REG in clinical practice. We conducted a random nationwide survey of 200 hand therapists. The questionnaire items regarding the administration of the REG included patient position, test instructions, handle settings, handling of the dynamometer, hand switch rate, number of repetitions, and techniques used to record the score. The items for the interpretation of the REG involved questions regarding comparative tests. We found that the REG test lacks standardized administration protocols and interpretation criteria among therapists nationwide. The lack of standardization is likely to affect the reliability and validity of the REG and to hinder the therapist's ability to accurately report its outcomes. The implications of lack of standardization in assessment techniques to the profession are discussed.

  13. Is the coefficient of variation a valid measure for detecting sincerity of effort of grip strength?

    Science.gov (United States)

    Shechtman, Orit

    1999-01-01

    The wide use of the coefficient of variation in detecting sincerity of effort is puzzling since existing research findings regarding its effectiveness are contradictory. The lack of empirical support in the literature raises the question of whether or not the coefficient of variation is a valid measure for detecting sincerity of effort. Many clinicians, especially those who use a computer software to calculate the coefficient of variation, may not understand how the coefficient of variation is derived and what it is based on. The coefficient of variation is a measure of relative variability and would be used correctly only if the average and the standard deviation of grip strength trials increased proportionally. This case study, however, demonstrated that the average and standard deviation of grip strength are independent. Thus, the coefficient of variation is not a valid measure of sincerity of effort. In addition, this study indicated that the coefficient of variation may be inflated in individuals after carpal tunnel release surgery. The author, therefore, cautions clinicians against the use of the coefficient of variation as a measure of sincerity of effort especially in injured individuals with compromised hand strength.

  14. Grip selection for sequential movements in children and adults with and without Developmental Coordination Disorder.

    Science.gov (United States)

    Wilmut, Kate; Byrne, Maia

    2014-08-01

    When generating a movement adults favor grasps which start the body in an uncomfortable position if they end in a comfortable position (the end-state-comfort effect). In contrast, children with Developmental Coordination Disorder (DCD) select grasps which require little initial hand rotation even though they result in an uncomfortable end position. The current study considered grip selection of individuals with DCD when asked to make simple one step movements and when making more complex multi-staged movements. Adults with DCD (N=17, mean age 24:09, SD age=52months) and children with DCD (N=20, mean age 9:00, SD age=20months) and age and gender matched controls rotated a disc so an arrow pointed toward a specific target(s). Task complexity was increased by increasing the number of targets from 1 to 3. Planning for end-state-comfort was seen in all groups albeit to a lesser extent in children versus adults. The children with DCD showed fewer grips for end-state-comfort compared to their peers and this was explained by a propensity to select minimal initial rotation grasps. This result was mirrored in adults with DCD but only for the longest movement sequence. These results suggest some changes in ability from childhood to adulthood in individuals with DCD.

  15. Hurricane Imaging Radiometer Wind Speed and Rain Rate Retrievals during the 2010 GRIP Flight Experiment

    Science.gov (United States)

    Sahawneh, Saleem; Farrar, Spencer; Johnson, James; Jones, W. Linwood; Roberts, Jason; Biswas, Sayak; Cecil, Daniel

    2014-01-01

    Microwave remote sensing observations of hurricanes, from NOAA and USAF hurricane surveillance aircraft, provide vital data for hurricane research and operations, for forecasting the intensity and track of tropical storms. The current operational standard for hurricane wind speed and rain rate measurements is the Stepped Frequency Microwave Radiometer (SFMR), which is a nadir viewing passive microwave airborne remote sensor. The Hurricane Imaging Radiometer, HIRAD, will extend the nadir viewing SFMR capability to provide wide swath images of wind speed and rain rate, while flying on a high altitude aircraft. HIRAD was first flown in the Genesis and Rapid Intensification Processes, GRIP, NASA hurricane field experiment in 2010. This paper reports on geophysical retrieval results and provides hurricane images from GRIP flights. An overview of the HIRAD instrument and the radiative transfer theory based, wind speed/rain rate retrieval algorithm is included. Results are presented for hurricane wind speed and rain rate for Earl and Karl, with comparison to collocated SFMR retrievals and WP3D Fuselage Radar images for validation purposes.

  16. The effect of vibration exposure during haul truck operation on grip strength, touch sensation, and balance.

    Science.gov (United States)

    Pollard, Jonisha; Porter, William; Mayton, Alan; Xu, Xueyan; Weston, Eric

    2017-01-01

    Falls from mobile equipment are reported at surface mine quarry operations each year in considerable numbers. Research shows that a preponderance of falls occur while getting on/off mobile equipment. Contributing factors to the risk of falls include the usage of ladders, exiting onto a slippery surface, and foot or hand slippage. Balance issues may also contribute to fall risks for mobile equipment operators who are exposed to whole-body vibration (WBV). For this reason, the National Institute for Occupational Safety and Health, Office of Mine Safety and Health Research conducted a study at four participating mine sites with seven haul truck operators. The purpose was to ascertain whether WBV and hand-arm vibration (HAV) exposures for quarry haul truck operators were linked to short-term decreases in performance in relation to postural stability, touch sensation threshold, and grip strength that are of crucial importance when getting on/off the trucks. WBV measures of frequency-weighted RMS accelerations (wRMS) and vibration dose value (VDV), when compared to the ISO/ANSI standards, were mostly below levels identified for the Health Guidance Caution Zone (HGCZ), although there were instances where the levels were within and above the specified Exposure Action Value. Comparably, all mean HAV levels, when compared to the ISO/ANSI standards, were below the HGCZ. For the existing conditions and equipment, no significant correlation could be identified between the WBV, HAV, postural stability, touch sensation threshold, and grip strength measures taken during this study.

  17. Optimal Tuning of Amplitude Proportional Coulomb Friction Damper for Maximum Cable Damping

    DEFF Research Database (Denmark)

    Weber, Felix; Høgsberg, Jan Becker; Krenk, Steen

    2010-01-01

    This paper investigates numerically the optimal tuning of Coulomb friction dampers on cables, where the optimality criterion is maximum additional damping in the first vibration mode. The expression for the optimal friction force level of Coulomb friction dampers follows from the linear viscous...... damper via harmonic averaging. It turns out that the friction force level has to be adjusted in proportion to cable amplitude at damper position which is realized by amplitude feedback in real time. The performance of this adaptive damper is assessed by simulated free decay curves from which the damping...... is estimated. It is found that the damping efficiency agrees well with the expected value at the theoretical optimum. However, maximum damping is larger and achieved at a force to amplitude ratio of 1.4 times the analytical value. Investigations show that the increased damping results from energy spillover...

  18. The coefficient of variation as a measure of sincerity of effort of grip strength, Part I: the statistical principle.

    Science.gov (United States)

    Shechtman, O

    2001-01-01

    The coefficient of variation (CV) is a widely used measure of sincerity of effort of grip strength despite contradictory research findings and lack of empirical support in the literature. The purpose of this study was to investigate whether the CV is an appropriate measure of sincerity of effort. One hundred forty-six uninjured volunteers underwent a series of grip strength tests. The mean, standard deviation (SD), and CV of repeated strength trials were calculated, and paired comparisons were conducted between maximal and submaximal efforts. While the mean of maximal trials was significantly greater, there were no differences in SD between maximal and submaximal trials. Therefore, the increased CV associated with submaximal effort was an artifact of reduced torque rather than an indicator of a true increase in variability. Consequently, the CV is not an appropriate measure of sincerity of effort of grip strength.

  19. Holographic corrections to meson scattering amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Armoni, Adi; Ireson, Edwin, E-mail: 746616@swansea.ac.uk

    2017-06-15

    We compute meson scattering amplitudes using the holographic duality between confining gauge theories and string theory, in order to consider holographic corrections to the Veneziano amplitude and associated higher-point functions. The generic nature of such computations is explained, thanks to the well-understood nature of confining string backgrounds, and two different examples of the calculation in given backgrounds are used to illustrate the details. The effect we discover, whilst only qualitative, is re-obtainable in many such examples, in four-point but also higher point amplitudes.

  20. Hidden simplicity of gauge theory amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Drummond, J M, E-mail: drummond@lapp.in2p3.f [LAPTH, Universite de Savoie, CNRS, B.P. 110, F-74941 Annecy-le-Vieux, Cedex (France)

    2010-11-07

    These notes were given as lectures at the CERN Winter School on Supergravity, Strings and Gauge Theory 2010. We describe the structure of scattering amplitudes in gauge theories, focussing on the maximally supersymmetric theory to highlight the hidden symmetries which appear. Using the Britto, Cachzo, Feng and Witten (BCFW) recursion relations we solve the tree-level S-matrix in N=4 super Yang-Mills theory and describe how it produces a sum of invariants of a large symmetry algebra. We review amplitudes in the planar theory beyond tree level, describing the connection between amplitudes and Wilson loops, and discuss the implications of the hidden symmetries.

  1. Hidden simplicity of gauge theory amplitudes

    Science.gov (United States)

    Drummond, J. M.

    2010-11-01

    These notes were given as lectures at the CERN Winter School on Supergravity, Strings and Gauge Theory 2010. We describe the structure of scattering amplitudes in gauge theories, focussing on the maximally supersymmetric theory to highlight the hidden symmetries which appear. Using the Britto, Cachzo, Feng and Witten (BCFW) recursion relations we solve the tree-level S-matrix in \\ {N}=4 super Yang-Mills theory and describe how it produces a sum of invariants of a large symmetry algebra. We review amplitudes in the planar theory beyond tree level, describing the connection between amplitudes and Wilson loops, and discuss the implications of the hidden symmetries.

  2. Holographic Corrections to Meson Scattering Amplitudes

    CERN Document Server

    Armoni, Adi

    2016-01-01

    We compute meson scattering amplitudes using the holographic duality between confining gauge theories and string theory, in order to consider holographic corrections to the Veneziano amplitude and associated higher-point functions. The generic nature of such computations is explained, thanks to the well-understood nature of confining string backgrounds, and two different examples of the calculation in given backgrounds are used to illustrate the details. The effect we discover, whilst only qualitative, is re-obtainable in many such examples, in four-point but also higher point amplitudes.

  3. Softness and Amplitudes' Positivity for Spinning Particles

    CERN Document Server

    Bellazzini, Brando

    2016-01-01

    We derive positivity bounds for scattering amplitudes of particles with arbitrary spin using unitarity, analyticity and crossing symmetry. The bounds imply the positivity of certain low-energy coefficients of the effective action that controls the dynamics of the light degrees of freedom. We show that low-energy amplitudes strictly softer than $O(p^4)$ do not admit unitary ultraviolet completions unless the theory is free. This enforces a bound on the energy growth of scattering amplitudes in the region of validity of the effective theory. We discuss explicit examples including the Goldstino from spontaneous supersymmetry breaking, and the theory of a spin-1/2 fermion with a shift symmetry.

  4. Target tracking based on frequency spectrum amplitude

    Institute of Scientific and Technical Information of China (English)

    Guo Huidong; Zhang Xinhua; Xia Zhijun

    2006-01-01

    The amplitude of frequency spectrum can be integrated with probabilistic data association (PDA) to distinguish the target with clutter echoes, especially in low SNR underwater environment. A new target-tracking algorithm is presented which adopts the amplitude of frequency spectrum to improve target tracking in clutter. The probabilistic density distribution of frequency spectrum amplitude is analyzed. By simulation, the results show that the algorithm is superior to PDA. This approach enhances stability for the association probability and increases the performance of target tracking.

  5. GRIP: A web-based system for constructing Gold Standard datasets for protein-protein interaction prediction.

    Science.gov (United States)

    Browne, Fiona; Wang, Haiying; Zheng, Huiru; Azuaje, Francisco

    2009-01-26

    Information about protein interaction networks is fundamental to understanding protein function and cellular processes. Interaction patterns among proteins can suggest new drug targets and aid in the design of new therapeutic interventions. Efforts have been made to map interactions on a proteomic-wide scale using both experimental and computational techniques. Reference datasets that contain known interacting proteins (positive cases) and non-interacting proteins (negative cases) are essential to support computational prediction and validation of protein-protein interactions. Information on known interacting and non interacting proteins are usually stored within databases. Extraction of these data can be both complex and time consuming. Although, the automatic construction of reference datasets for classification is a useful resource for researchers no public resource currently exists to perform this task. GRIP (Gold Reference dataset constructor from Information on Protein complexes) is a web-based system that provides researchers with the functionality to create reference datasets for protein-protein interaction prediction in Saccharomyces cerevisiae. Both positive and negative cases for a reference dataset can be extracted, organised and downloaded by the user. GRIP also provides an upload facility whereby users can submit proteins to determine protein complex membership. A search facility is provided where a user can search for protein complex information in Saccharomyces cerevisiae. GRIP is developed to retrieve information on protein complex, cellular localisation, and physical and genetic interactions in Saccharomyces cerevisiae. Manual construction of reference datasets can be a time consuming process requiring programming knowledge. GRIP simplifies and speeds up this process by allowing users to automatically construct reference datasets. GRIP is free to access at http://rosalind.infj.ulst.ac.uk/GRIP/.

  6. GRIP: A web-based system for constructing Gold Standard datasets for protein-protein interaction prediction

    Directory of Open Access Journals (Sweden)

    Zheng Huiru

    2009-01-01

    Full Text Available Abstract Background Information about protein interaction networks is fundamental to understanding protein function and cellular processes. Interaction patterns among proteins can suggest new drug targets and aid in the design of new therapeutic interventions. Efforts have been made to map interactions on a proteomic-wide scale using both experimental and computational techniques. Reference datasets that contain known interacting proteins (positive cases and non-interacting proteins (negative cases are essential to support computational prediction and validation of protein-protein interactions. Information on known interacting and non interacting proteins are usually stored within databases. Extraction of these data can be both complex and time consuming. Although, the automatic construction of reference datasets for classification is a useful resource for researchers no public resource currently exists to perform this task. Results GRIP (Gold Reference dataset constructor from Information on Protein complexes is a web-based system that provides researchers with the functionality to create reference datasets for protein-protein interaction prediction in Saccharomyces cerevisiae. Both positive and negative cases for a reference dataset can be extracted, organised and downloaded by the user. GRIP also provides an upload facility whereby users can submit proteins to determine protein complex membership. A search facility is provided where a user can search for protein complex information in Saccharomyces cerevisiae. Conclusion GRIP is developed to retrieve information on protein complex, cellular localisation, and physical and genetic interactions in Saccharomyces cerevisiae. Manual construction of reference datasets can be a time consuming process requiring programming knowledge. GRIP simplifies and speeds up this process by allowing users to automatically construct reference datasets. GRIP is free to access at http://rosalind.infj.ulst.ac.uk/GRIP/.

  7. Modeling the Maturation of Grip Selection Planning and Action Representation: Insights from Typical and Atypical Motor Development.

    Directory of Open Access Journals (Sweden)

    Ian eFuelscher

    2016-02-01

    Full Text Available We investigated the purported association between developmental changes in grip selection planning and improvements in an individual’s capacity to represent action at an internal level (i.e., motor imagery. Participants were groups of healthy children aged 6-7 years and 8-12 years respectively, while a group of adolescents (13-17 years and adults (18-34 years allowed for consideration of childhood development in the broader context of motor maturation. A group of children aged 8-12 years with probable DCD (pDCD was included as a reference group for atypical motor development. Participants’ proficiency to generate and/or engage internal action representations was inferred from performance on the hand rotation task, a well-validated measure of motor imagery. A grip selection task designed to elicit the end-state comfort (ESC effect provided a window into the integrity of grip selection planning. Consistent with earlier accounts, the efficiency of grip selection planning followed a non-linear developmental progression in neurotypical individuals. As expected, analysis confirmed that these developmental improvements were predicted by an increased capacity to generate and/or engage internal action representations. The profile of this association remained stable throughout the (typical developmental spectrum. These findings are consistent with computational accounts of action planning that argue that internal action representations are associated with the expression and development of grip selection planning across typical development. However, no such association was found for our sample of children with pDCD, suggesting that individuals with atypical motor skill may adopt an alternative, sub-optimal strategy to plan their grip selection compared to their same-age control peers.

  8. [Evaluation of grip strength in normal and obese Wistar rats submitted to swimming with overload after median nerve compression].

    Science.gov (United States)

    Coradinia, Josinéia Gresele; Kakihata, Camila Mayumi Martin; Kunz, Regina Inês; Errero, Tatiane Kamada; Bonfleur, Maria Lúcia; Bertolini, Gladson Ricardo Flor

    2015-01-01

    To verify the functionality through muscle grip strength in animals with obesity induced by monosodium glutamate (MSG) and in control animals, which suffered compression of the right median nerve, and treated with swimming with overload. During the first five days of life, neonatal Wistar rats received subcutaneous injections of MSG. The control group received a hypertonic saline solution. Forty-eight rats were divided into six groups: G1 (control); G2 (control + injury); G3 (control + injury + swimming); G4 (obese); G5 (obese + injury); G6 (obese + injury + swimming). The animals in groups G2, G3, G5 and G6 were submitted to compression of the median nerve and G3 and G6 groups were treated, after injury, with swimming exercise with load for three weeks. The swimming exercise had a progressive duration, according to the week, of 20, 30 and 40minutes. Muscle strength was assessed using a grip strength meter preoperatively and on the 3rd, 7th, 14th and 21st days after surgery. The results were expressed and analyzed using descriptive and inferential statistics. When the grip strength was compared among assessments regardless of group, in the second assessment the animals exhibited lower grip strength. G1 and G4 groups had greater grip strength, compared to G2, G3, G4 and G6. The swimming exercise with overload has not been effective in promoting improvement in muscle grip strength after compression injury of the right median nerve in control and in obese-MSG rats. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  9. Modeling the Maturation of Grip Selection Planning and Action Representation: Insights from Typical and Atypical Motor Development

    Science.gov (United States)

    Fuelscher, Ian; Williams, Jacqueline; Wilmut, Kate; Enticott, Peter G.; Hyde, Christian

    2016-01-01

    We investigated the purported association between developmental changes in grip selection planning and improvements in an individual’s capacity to represent action at an internal level [i.e., motor imagery (MI)]. Participants were groups of healthy children aged 6–7 years and 8–12 years respectively, while a group of adolescents (13–17 years) and adults (18–34 years) allowed for consideration of childhood development in the broader context of motor maturation. A group of children aged 8–12 years with probable DCD (pDCD) was included as a reference group for atypical motor development. Participants’ proficiency to generate and/or engage internal action representations was inferred from performance on the hand rotation task, a well-validated measure of MI. A grip selection task designed to elicit the end-state comfort (ESC) effect provided a window into the integrity of grip selection planning. Consistent with earlier accounts, the efficiency of grip selection planning followed a non-linear developmental progression in neurotypical individuals. As expected, analysis confirmed that these developmental improvements were predicted by an increased capacity to generate and/or engage internal action representations. The profile of this association remained stable throughout the (typical) developmental spectrum. These findings are consistent with computational accounts of action planning that argue that internal action representations are associated with the expression and development of grip selection planning across typical development. However, no such association was found for our sample of children with pDCD, suggesting that individuals with atypical motor skill may adopt an alternative, sub-optimal strategy to plan their grip selection compared to their same-age control peers. PMID:26903915

  10. Effect of isometric hand grip on heart rate in normotensive and hypertensive individuals during head up tilt (300 and 600)

    OpenAIRE

    Badwe, A. N.; Latti, Ramchandra Girimalappa

    2017-01-01

    Objective: To study the effect of isometric hand grip exercise at 20% on normotensive, treated hypertensive, and non treated hypertensive in supine position, and at 300 and 600 head up tilt.Material and Methods: After recording heart rate in supine position, isometric hand grip exercise at 20% was conducted for 2 minutes with dominant hand and heart rate was recorded for 1 minute in all subjects after end of the exercise. The same maneuver was repeated before head up tilt in supine position a...

  11. Open String Amplitudes in Various Gauges

    CERN Document Server

    Fuji, H; Suzuki, H; Fuji, Hiroyuki; Nakayama, Shinsaku; Suzuki, Hisao

    2007-01-01

    Recently, Schnabl constructed the analytic solution of the open string tachyon. Subsequently, the absence of the physical states at the vacuum was proved. The development relies heavily on the use of the gauge condition different from the ordinary one. It was shown that the choice of gauge simplifies the analysis drastically. When we perform the calculation of the amplitudes in Schnabl gauge, we find that the off-shell amplitudes of the Schnabl gauge is still very complicated. In this paper, we propose the use of the propagator in the modified Schnabl gauge and show that this modified use of the Schnabl gauge simplifies the computation of the off-shell amplitudes drastically. We also compute the amplitudes of open superstring in this gauge.

  12. Scattering Amplitudes via Algebraic Geometry Methods

    CERN Document Server

    Søgaard, Mads; Damgaard, Poul Henrik

    This thesis describes recent progress in the understanding of the mathematical structure of scattering amplitudes in quantum field theory. The primary purpose is to develop an enhanced analytic framework for computing multiloop scattering amplitudes in generic gauge theories including QCD without Feynman diagrams. The study of multiloop scattering amplitudes is crucial for the new era of precision phenomenology at the Large Hadron Collider (LHC) at CERN. Loop-level scattering amplitudes can be reduced to a basis of linearly independent integrals whose coefficients are extracted from generalized unitarity cuts. We take advantage of principles from algebraic geometry in order to extend the notion of maximal cuts to a large class of two- and three-loop integrals. This allows us to derive unique and surprisingly compact formulae for the coefficients of the basis integrals. Our results are expressed in terms of certain linear combinations of multivariate residues and elliptic integrals computed from products of ...

  13. Off-shell Amplitudes in Superstring Theory

    CERN Document Server

    Sen, Ashoke

    2014-01-01

    Computing the renormalized masses and S-matrix elements in string theory, involving states whose masses are not protected from quantum corrections, requires defining off-shell amplitude with certain factorization properties. While in the bosonic string theory one can in principle construct such an amplitude from string field theory, there is no fully consistent field theory for superstring and heterotic string theory. In this paper we give a practical construction of off-shell amplitudes satisfying the desired factorization property using the formalism of picture changing operators. We describe a systematic procedure for dealing with the spurious singularities of the integration measure that we encounter when the supermoduli space is not holomorphically projected. This procedure is also useful for computing on-shell amplitudes, as we demonstrate by computing the effect of Fayet-Iliopoulos D-terms in four dimensional heterotic string theory compactifications using this formalism.

  14. Feynman Amplitudes in Mathematics and Physics

    OpenAIRE

    Bloch, Spencer

    2015-01-01

    These are notes of lectures given at the CMI conference in August, 2014 at ICMAT in Madrid. The focus is on some mathematical questions associated to Feynman amplitudes, including Hodge structures, relations with string theory, and monodromy (Cutkosky rules).

  15. Stora's fine notion of divergent amplitudes

    CERN Document Server

    Várilly, Joseph C

    2016-01-01

    Stora and coworkers refined the notion of divergent quantum amplitude, somewhat upsetting the standard power-counting recipe. This unexpectedly clears the way to new prototypes for free and interacting field theories of bosons of any mass and spin.

  16. Open string amplitudes of closed topological vertex

    CERN Document Server

    Takasaki, Kanehisa

    2016-01-01

    The closed topological vertex is the simplest "off-strip" case of non-compact toric Calabi-Yau threefolds with acyclic web diagrams. By the diagrammatic method of topological vertex, open string amplitudes of topological string theory therein can be obtained by gluing a single topological vertex to an "on-strip" subdiagram of the tree-like web diagram. If non-trivial partitions are assigned to just two parallel external lines of the web diagram, the amplitudes can be calculated with the aid of techniques borrowed from the melting crystal models. These amplitudes are thereby expressed as matrix elements, modified by simple prefactors, of an operator product on the Fock space of 2D charged free fermions. This fermionic expression can be used to derive $q$-difference equations for generating functions of special subsets of the amplitudes. These $q$-difference equations may be interpreted as the defining equation of a quantum mirror curve.

  17. Amplitudes for left-handed strings

    CERN Document Server

    Siegel, W

    2015-01-01

    We consider a class of string-like models introduced previously where all modes are left-handed, all states are massless, T-duality is manifest, and only a finite number of orders in the string tension can appear. These theories arise from standard string theories by a singular gauge limit and associated change in worldsheet boundary conditions. In this paper we show how to calculate amplitudes by using the gauge parameter as an infrared regulator. The amplitudes produce the Cachazo-He-Yuan delta-functions after some modular integration; the Mason-Skinner string-like action and amplitudes arise from the zero-tension (infinite-slope) limit. However, without the limit the amplitudes have the same problems as found in the Mason-Skinner formalism.

  18. Force time-history affects fatigue accumulation during repetitive handgrip tasks.

    Science.gov (United States)

    Sonne, Michael W; Hodder, Joanne N; Wells, Ryan; Potvin, Jim R

    2015-02-01

    Muscle fatigue is associated with a higher risk of workplace injury, in particular during repetitive tasks. This study aimed to identify the effect of a complex force-time history (a task with multiple different submaximal effort levels) on fatigue accumulation and recovery during a handgrip task. We measured surface electromyography of the brachioradialis (BRD) and flexor carpi ulnaris (FCU) of ten right hand dominant females with no history of upper limb injury while they performed a complex submaximal visually targeted gripping task. The task consisted of 15%, 30%, 45%, 30%, and 15% maximum voluntary contraction (MVC) plateaus. Each plateau was held for 15s, followed by a 3s MVC and 3s of rest. The "pyramid" was repeated until fatigue criteria were met. Grip force, average EMG and mean power frequency (MnPF) for first cycle and fatigued last cycle, were compared. Post-plateau peak grip force was on average 20.5% MVC lower during the last cycle (pMVC after the first 15% MVC plateau (from baseline), by 5.3% MVC after the 30% MVC plateau and 6.8% MVC after the 45% MVC plateau. Further accumulation of fatigue after the second 30% MVC plateau however was minimal, only decreasing by 1.6% MVC. Recovery appeared to occur during the last 15% MVC plateau with an increase in post plateau grip force of 1.6% MVC. Interestingly, MnPF parameters confirmed significant fatigue accumulation during the back end of a force pyramid. We conclude that in a pattern of contractions with ascending, then descending force intensity, voluntary force recovery was present when the preceding force was of a lower intensity. These findings indicate preceding demands play a role in fatigue accumulation during complex tasks.

  19. Detection of combined frequency and amplitude modulation.

    Science.gov (United States)

    Moore, B C; Sek, A

    1992-12-01

    This article is concerned with the detection of mixed modulation (MM), i.e., simultaneously occurring amplitude modulation (AM) and frequency modulation (FM). In experiment 1, an adaptive two-alternative forced-choice task was used to determine thresholds for detecting AM alone. Then, thresholds for detecting FM were determined for stimuli which had a fixed amount of AM in the signal interval only. The amount of AM was always less than the threshold for detecting AM alone. The FM thresholds depended significantly on the magnitude of the coexisting AM. For low modulation rates (4, 16, and 64 Hz), the FM thresholds did not depend significantly on the relative phase of modulation for the FM and AM. For a high modulation rate (256 Hz) strong effects of modulator phase were observed. These phase effects are as predicted by the model proposed by Hartmann and Hnath [Acustica 50, 297-312 (1982)], which assumes that detection of modulation at modulation frequencies higher than the critical modulation frequency is based on detection of the lower sideband in the modulated signal's spectrum. In the second experiment, psychometric functions were measured for the detection of AM alone and FM alone, using modulation rates of 4 and 16 Hz. Results showed that, for each type of modulation, d' is approximately a linear function of the square of the modulation index. Application of this finding to the results of experiment 1 suggested that, at low modulation rates, FM and AM are not detected by completely independent mechanisms. In the third experiment, psychometric functions were again measured for the detection of AM alone and FM alone, using a 10-Hz modulation rate. Detectability was then measured for combined AM and FM, with modulation depths selected so that each type of modulation would be equally detectable if presented alone. Significant effects of relative modulator phase were found when detectability was relatively high. These effects were not correctly predicted by either a

  20. Short term microgravity effect on isometric hand grip and precision pinch force with visual and proprioceptive feedback

    Science.gov (United States)

    Pastacaldi, P.; Orsini, P.; Bracciaferri, F.; Neri, G.; Porciani, M.; Liuni, L.; Zolesi, V.

    2004-01-01

    Experiments executed on the upper limb are assuming increasing significance in the frame of the Human Physiology in space, for at least two reasons: the upper limb is the principal means of locomotion for the subject living in a space station; furthermore, fatigue can have a significant effect on the hand, for the ordinary work on board, and in particular for the extra-vehicular activities. The degradation of the performances affecting the muscular-skeletal apparatus can be easily recognized on the upper limb, by exerting specific scientific protocols, to be repeated through the permanence of the subject in weightlessness conditions. Another aspect relevant to the effect of microgravity on the upper limb is associated with the alteration of the motor control programs due to the different gravity factor, affecting not only the bio-mechanics of the subject, but in general all his/her psycho-physical conditions, induced by the totally different environment. Specific protocols on the upper limb can facilitate the studies on learning mechanisms for the motor control. The results of such experiments can be transferred to the Earth, useful for treatment of subjects with local traumas or diseases of the Central Nervous System.

  1. Improvement in precision grip force control with self-modulation of primary motor cortex during motor imagery

    Directory of Open Access Journals (Sweden)

    Maria Laura eBlefari

    2015-02-01

    Full Text Available Motor imagery (MI has shown effectiveness in enhancing motor performance. This may be due to the common neural mechanisms underlying MI and motor execution (ME. The main region of the ME network, the primary motor cortex (M1, has been consistently linked to motor performance. However, the activation of M1 during motor imagery is controversial, which may account for inconsistent rehabilitation therapy outcomes using MI. Here, we examined the relationship between contralateral M1 (cM1 activation during MI and changes in sensorimotor performance. To aid cM1 activity modulation during MI, we used real-time fMRI neurofeedback-guided MI based on cM1 hand area blood oxygen level dependent (BOLD signal in healthy subjects, performing kinesthetic MI of pinching. We used multiple regression analysis to examine the correlation between cM1 BOLD signal and changes in motor performance during an isometric pinching task of those subjects who were able to activate cM1 during motor imagery. Activities in premotor and parietal regions were used as covariates. We found that cM1 activity was positively correlated to improvements in accuracy as well as overall performance improvements, whereas other regions in the sensorimotor network were not. The association between cM1 activation during MI with performance changes indicates that subjects with stronger cM1 activation during MI may benefit more from MI training, with implications towards targeted neurotherapy.

  2. Motor Prediction at the Edge of Instability: Alteration of Grip Force Control during Changes in Bimanual Coordination

    Science.gov (United States)

    Danion, Frederic; Jirsa, Viktor K.

    2010-01-01

    Predicting the consequences of actions is fundamental for skilled motor behavior. We investigated whether motor prediction is influenced by the fact that some movements are easier to perform and stabilize than others. Twelve subjects performed a bimanual rhythmical task either symmetrically or asymmetrically (the latter being more difficult and…

  3. Mechanical models of amplitude and frequency modulation

    Energy Technology Data Exchange (ETDEWEB)

    Bellomonte, L; Guastella, I; Sperandeo-Mineo, R M [GRIAF - Research Group on Teaching/Learning Physics, DI.F.TE.R. -Dipartimento di Fisica e Tecnologie Relative, University of Palermo, Viale delle Scienze, Edificio 18, 90128 Palermo (Italy)

    2005-05-01

    This paper presents some mechanical models for amplitude and frequency modulation. The equations governing both modulations are deduced alongside some necessary approximations. Computer simulations of the models are carried out by using available educational software. Amplitude modulation is achieved by using a system of two weakly coupled pendulums, whereas the frequency modulation is obtained by using a pendulum of variable length. Under suitable conditions (small oscillations, appropriate initial conditions, etc) both types of modulation result in significantly accurate and visualized simulations.

  4. Simple parametrization of the. pi. -N amplitude

    Energy Technology Data Exchange (ETDEWEB)

    McLeod, R.J.; Afnan, I.R.

    1985-07-01

    We present a simple parametrization of the S-, P-, and D-wave ..pi..-N amplitudes using separable potentials for T/sub ..pi../<1 GeV. The effect of the inelasticity is included in the Green's function while maintaining consistency with unitarity. The P/sub 11/ amplitude is written as a pole plus nonpole in order to describe pion absorption in A> or =2.

  5. Feynman amplitudes and limits of heights

    Science.gov (United States)

    Amini, O.; Bloch, S. J.; Burgos Gil, J. I.; Fresán, J.

    2016-10-01

    We investigate from a mathematical perspective how Feynman amplitudes appear in the low-energy limit of string amplitudes. In this paper, we prove the convergence of the integrands. We derive this from results describing the asymptotic behaviour of the height pairing between degree-zero divisors, as a family of curves degenerates. These are obtained by means of the nilpotent orbit theorem in Hodge theory.

  6. Nucleon distribution amplitudes from lattice QCD

    Energy Technology Data Exchange (ETDEWEB)

    Goeckeler, M. [Regensburg Univ. (Germany). Inst. fuer Theoretische Physik; Horsley, R. [Edinburgh Univ. (United Kingdom). School of Physics; Kaltenbrunner, T. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (DE). John von Neumann-Inst. fuer Computing NIC] (and others)

    2008-04-15

    We calculate low moments of the leading-twist and next-to-leading twist nucleon distribution amplitudes on the lattice using two flavors of clover fermions. The results are presented in the MS scheme at a scale of 2 GeV and can be immediately applied in phenomenological studies. We find that the deviation of the leading-twist nucleon distribution amplitude from its asymptotic form is less pronounced than sometimes claimed in the literature. (orig.)

  7. Vowel identification by amplitude and phase contrast.

    Science.gov (United States)

    Molis, Michelle R; Diedesch, Anna; Gallun, Frederick; Leek, Marjorie R

    2013-02-01

    Vowel identification is largely dependent on listeners' access to the frequency of two or three peaks in the amplitude spectrum. Earlier work has demonstrated that, whereas normal-hearing listeners can identify harmonic complexes with vowel-like spectral shapes even with very little amplitude contrast between "formant" components and remaining harmonic components, listeners with hearing loss require greater amplitude differences. This is likely the result of the poor frequency resolution that often accompanies hearing loss. Here, we describe an additional acoustic dimension for emphasizing formant versus non-formant harmonics that may supplement amplitude contrast information. The purpose of this study was to determine whether listeners were able to identify "vowel-like" sounds using temporal (component phase) contrast, which may be less affected by cochlear loss than spectral cues, and whether overall identification improves when congruent temporal and spectral information are provided together. Five normal-hearing and five hearing-impaired listeners identified three vowels over many presentations. Harmonics representing formant peaks were varied in amplitude, phase, or a combination of both. In addition to requiring less amplitude contrast, normal-hearing listeners could accurately identify the sounds with less phase contrast than required by people with hearing loss. However, both normal-hearing and hearing-impaired groups demonstrated the ability to identify vowel-like sounds based solely on component phase shifts, with no amplitude contrast information, and they also showed improved performance when congruent phase and amplitude cues were combined. For nearly all listeners, the combination of spectral and temporal information improved identification in comparison to either dimension alone.

  8. Employing Helicity Amplitudes for Resummation in SCET

    CERN Document Server

    Moult, Ian; Tackmann, Frank J; Waalewijn, Wouter J

    2016-01-01

    Helicity amplitudes are the fundamental ingredients of many QCD calculations for multi-leg processes. We describe how these can seamlessly be combined with resummation in Soft-Collinear Effective Theory (SCET), by constructing a helicity operator basis for which the Wilson coefficients are directly given in terms of color-ordered helicity amplitudes. This basis is crossing symmetric and has simple transformation properties under discrete symmetries.

  9. Quartic amplitudes for Minkowski higher spin

    CERN Document Server

    Bengtsson, Anders K H

    2016-01-01

    The problem of finding general quartic interaction terms between fields of higher helicities on the light-front is discussed from the point of view of calculating the corresponding amplitudes directly from the cubic vertices using BCFW recursion. Amplitude based no-go results that has appeared in the literature are reviewed and discussed and it is pointed out how they may perhaps be circumvented.

  10. Amplitude metrics for cellular circadian bioluminescence reporters.

    Science.gov (United States)

    St John, Peter C; Taylor, Stephanie R; Abel, John H; Doyle, Francis J

    2014-12-01

    Bioluminescence rhythms from cellular reporters have become the most common method used to quantify oscillations in circadian gene expression. These experimental systems can reveal phase and amplitude change resulting from circadian disturbances, and can be used in conjunction with mathematical models to lend further insight into the mechanistic basis of clock amplitude regulation. However, bioluminescence experiments track the mean output from thousands of noisy, uncoupled oscillators, obscuring the direct effect of a given stimulus on the genetic regulatory network. In many cases, it is unclear whether changes in amplitude are due to individual changes in gene expression level or to a change in coherence of the population. Although such systems can be modeled using explicit stochastic simulations, these models are computationally cumbersome and limit analytical insight into the mechanisms of amplitude change. We therefore develop theoretical and computational tools to approximate the mean expression level in large populations of noninteracting oscillators, and further define computationally efficient amplitude response calculations to describe phase-dependent amplitude change. At the single-cell level, a mechanistic nonlinear ordinary differential equation model is used to calculate the transient response of each cell to a perturbation, whereas population-level dynamics are captured by coupling this detailed model to a phase density function. Our analysis reveals that amplitude changes mediated at either the individual-cell or the population level can be distinguished in tissue-level bioluminescence data without the need for single-cell measurements. We demonstrate the effectiveness of the method by modeling experimental bioluminescence profiles of light-sensitive fibroblasts, reconciling the conclusions of two seemingly contradictory studies. This modeling framework allows a direct comparison between in vitro bioluminescence experiments and in silico ordinary

  11. Effective gluon interactions from superstring disk amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Oprisa, D.

    2006-05-15

    In this thesis an efficient method for the calculation of the N-point tree-level string amplitudes is presented. Furthermore it is shown that the six-gluon open-superstring disk amplitude can be expressed by a basis of six triple hypergeometric functions, which encode the full {alpha}' dependence. In this connection material for obtaining the {alpha}' expansion of these functions is derived. Hereby many Euler-Zagier sums are calculated including multiple harmonic series. (HSI)

  12. Implementation of Recursion Relations in Gluon Scattering Amplitude Calculations in AdS4 /CFT3

    Science.gov (United States)

    Dokmetzoglou, Nikolaos; Kharel, Savan

    2017-01-01

    The Anti-de Sitter/Conformal Field Theory (AdS/CFT) correspondence is a duality between a theory of gravity in curved-space (AdS) and a conformally-invariant quantum field theory in flat-space (CFT). Scattering amplitudes are observables associated with the probability of the interaction of a given assembly of particles. Gluons, being the exchange particles associated with the strong nuclear force, which holds quarks together to form protons, are abundant byproducts of fundamental particle collisions. Thus, studying gluon scattering amplitudes is an effective way of deepening our understanding of these observables in AdS/CFT. Traditionally, Feynman diagrams have been used to calculate such scattering amplitudes. In this project, we use factorization properties and recursion relations to simplify these calculations. More specifically, we calculate multiple (different helicity combinations) four-point gluon scattering amplitudes in AdS4 /CFT3 (4-D AdS and 3-D CFT) as sums of products of three-point amplitudes. And then we calculate a five-point gluon scattering amplitude in AdS4 /CFT3 by decomposing it into a sum of products of these four-point and three-point amplitudes. Finally we comment on useful identities for checking these amplitudes. This work was supported by a Weinstein Davidson College Research Initiative Summer Research grant.

  13. Force Development during Target-Directed Isometric Force Production in Parkinson’s Disease

    OpenAIRE

    Park, Jin-Hoon; Stelmach, George E.

    2006-01-01

    Performing various daily activities requires precise application and control of forces, which has been well addressed in neurologically healthy individuals. Recent experiments have demonstrated that in young, normal subjects generating rapid force pulses over various force amplitudes was accomplished by linearly increasing the rate of force development while keeping time to peak force approximately constant (i.e., a pulse-height control strategy). Using Parkinson’s disease (PD) patients the p...

  14. Recent Developments: The Gamma Ray Imager/Polarimeter for Solar Flares (GRIPS) Imaging and Detector systems

    Science.gov (United States)

    Duncan, Nicole; Shih, A. Y.; Hurford, G. J.; Saint-Hilaire, P.; Bain, H.; Zoglauer, A.; Lin, R. P.; Boggs, S. E.

    2013-07-01

    In two of the best-observed flares of the last cycle, the Reuven Ramaty High-Energy Solar Spectroscopic Imager (RHESSI) satellite found the centroids of ion and relativistic electron emission to have a significant displacement. This result is surprising; co-spatially accelerated ions and electrons are thought to be transported along the same field lines, implying they would enter the chromosphere together and have similar emission locations. The Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS) balloon instrument will investigate particle transport in solar flares by providing enhanced imaging, spectroscopy and polarimetry of gamma/HXR flare emission (20keV - 10MeV). GRIPS’ key technological improvements over the solar state of the art in HXR/gamma ray energies (RHESSI) include three-dimensional position-sensitive germanium detectors (3D-GeDs) and a single-grid modulating collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs allow GRIPS to Compton track energy deposition within the crystal. This capability (1) enables the MPRM design by acting as a second modulation grid, (2) provides significant background rejection and (3) makes solar polarization measurements possible. The MPRM imager provides quasi-continuous resolution from 12.5 - 162 arcsecs with 2x the throughput of a dual grid collimator system like RHESSI. This spatial resolution can resolve the separate footpoints of many flare sizes. In comparison, RHESSI images with a minimum of 35 arcsecs for gamma-rays, making these footpoints resolvable in only the largest flares. Here, we present the intial calibration of GRIPS’ 3D-GED detectors using laboratory radioactive sources. We evaluate charge sharing between adjacent strips, the detection of coincidences and preliminary depth measurements. The detectors have been shown to have a linear response and resolve line emission. The MPRM modulation grid is constructed and we present initial results from calibration. GRIPS is scheduled for a

  15. Amplitude Modulations of Acoustic Communication Signals

    Science.gov (United States)

    Turesson, Hjalmar K.

    2011-12-01

    In human speech, amplitude modulations at 3 -- 8 Hz are important for discrimination and detection. Two different neurophysiological theories have been proposed to explain this effect. The first theory proposes that, as a consequence of neocortical synaptic dynamics, signals that are amplitude modulated at 3 -- 8 Hz are propagated better than un-modulated signals, or signals modulated above 8 Hz. This suggests that neural activity elicited by vocalizations modulated at 3 -- 8 Hz is optimally transmitted, and the vocalizations better discriminated and detected. The second theory proposes that 3 -- 8 Hz amplitude modulations interact with spontaneous neocortical oscillations. Specifically, vocalizations modulated at 3 -- 8 Hz entrain local populations of neurons, which in turn, modulate the amplitude of high frequency gamma oscillations. This suggests that vocalizations modulated at 3 -- 8 Hz should induce stronger cross-frequency coupling. Similar to human speech, we found that macaque monkey vocalizations also are amplitude modulated between 3 and 8 Hz. Humans and macaque monkeys share similarities in vocal production, implying that the auditory systems subserving perception of acoustic communication signals also share similarities. Based on the similarities between human speech and macaque monkey vocalizations, we addressed how amplitude modulated vocalizations are processed in the auditory cortex of macaque monkeys, and what behavioral relevance modulations may have. Recording single neuron activity, as well as, the activity of local populations of neurons allowed us to test both of the neurophysiological theories presented above. We found that single neuron responses to vocalizations amplitude modulated at 3 -- 8 Hz resulted in better stimulus discrimination than vocalizations lacking 3 -- 8 Hz modulations, and that the effect most likely was mediated by synaptic dynamics. In contrast, we failed to find support for the oscillation-based model proposing a

  16. Strengthening the reporting of genetic risk prediction studies: the GRIPS statement.

    Science.gov (United States)

    Janssens, A Cecile J W; Ioannidis, John P A; van Duijn, Cornelia M; Little, Julian; Khoury, Muin J

    2011-09-01

    • The rapid and continuing progress in gene discovery for complex diseases is fuelling interest in the potential application of genetic risk models for clinical and public health practice. • The number of studies assessing the predictive ability is steadily increasing, but the quality and completeness of reporting vary. • A multidisciplinary workshop sponsored by the Human Genome Epidemiology Network developed a checklist of 25 items recommended for strengthening the reporting of Genetic RIsk Prediction Studies (GRIPS), building on the principles established by prior reporting guidelines. • These recommendations aim to enhance the transparency of study reporting and thereby to improve the synthesis and application of information from multiple studies that might differ in design, conduct or analysis. • A detailed Explanation and Elaboration document is published as an accompanying article [1].

  17. Electromagnet Gripping in Iron Foundry Automation Part I: Principles and Framework

    Directory of Open Access Journals (Sweden)

    Rhythm Suren Wadhwa

    2011-11-01

    Full Text Available Robot grippers are employed to position and retain parts in automated assembly operations. This paper presents an overview of electromagnet part handling framework in an iron foundry and an equivalent electromagnet circuit model. The manner in which this whole concept of automated gripping system operates will be discussed in this paper. The material handling system uses machine vision system coupled with conveyor motion and Ethernet communication strategy to assist the material handling system for transporting the foundry parts. The paper provides an overview of the electromagnet principles at play. The electromagnet interaction with the part is the key issue in the robust handling of this automated foundry system. This paper helps in the realization of the concept of automation in an iron foundry, in which the number of published studies is very limited.

  18. Electrical conductivity measurements from the GISP2 and GRIP Greenland ice cores

    DEFF Research Database (Denmark)

    Dahl-Jensen, Dorthe; Clausen, Henrik Brink; Taylor, K. C.

    1993-01-01

    . Here we present electrical conductivity records for the Greenland Ice Sheet Project 2 (GISP2) and Greenland Ice-core Project (GRIP) ice cores, drilled 28 km apart to enable direct comparison of the results. The upper parts of both records are consistent with previous evidence from other Greenland cores......THE direct-current electrical conductivity of glacial ice depends on its acidity1-3, and can also indicate changes in climate, as ice formed in cold, dusty periods has a high concentration of alkaline dust1,4,5, which significantly reduces the conductivity6,7 compared to warmer, less dusty periods......4,8& #150;12 for a stable Greenland climate during the Holocene, and a series of warm events punctuating the last glacial period. However, there is a significant discrepancy between the two records in the bottom 10% of the cores, calling into question recent reports of climate variability...

  19. Using the coefficient of variation to detect sincerity of effort of grip strength: a literature review.

    Science.gov (United States)

    Shechtman, O

    2000-01-01

    Many clinicians use the coefficient of variation (CV) to assess sincerity of effort, without understanding the premise on which it is based or its physiological and mathematical bases. Clinicians who use computerized evaluation systems that calculate the CV may not even be aware of the formula used to derive it. The wide use of the CV in detecting sincerity of effort of grip strength is puzzling, since it lacks empirical support in the literature. This paper examines the physiological rationale for using measures of variability to detect sincerity of effort, the mathematical basis on which the CV is founded, and the reliability and validity of the CV. The conclusions based on this literature review are that the CV is not an appropriate method for determining whether an effort is sincere and that CV values may be inflated in injured patients with compromised hand strength.

  20. Computer vision-based classification of hand grip variations in neurorehabilitation.

    Science.gov (United States)

    Zariffa, José; Steeves, John D

    2011-01-01

    The complexity of hand function is such that most existing upper limb rehabilitation robotic devices use only simplified hand interfaces. This is in contrast to the importance of the hand in regaining function after neurological injury. Computer vision technology has been used to identify hand posture in the field of Human Computer Interaction, but this approach has not been translated to the rehabilitation context. We describe a computer vision-based classifier that can be used to discriminate rehabilitation-relevant hand postures, and could be integrated into a virtual reality-based upper limb rehabilitation system. The proposed system was tested on a set of video recordings from able-bodied individuals performing cylindrical grasps, lateral key grips, and tip-to-tip pinches. The overall classification success rate was 91.2%, and was above 98% for 6 out of the 10 subjects. © 2011 IEEE

  1. Hurricanes Karl and Tropical Storm Matthew Structure Observed by HIWRAP During GRIP

    Science.gov (United States)

    Heymsfield, G. M.; Guimond, S. R.; Tian, L.

    2012-12-01

    The dual-wavelength (Ku and Ka band) High-Altitude Imaging Wind and Rain Airborne Profiler (HIWRAP) flew for the first time on the Global Hawk during the 2010 Genesis and Rapid Intensification Processes (GRIP). HIWRAP is conical scanning and Doppler, and winds and reflectivity can be mapped within the swath below the Global Hawk. Two interesting cases from the HIWRAP flights were the rapid intensification of Hurricane Karl and the intensification of Tropical Storm Matthew. This presentation will highlight the precipitation and wind structure of these storms during their intensification as derived from the HIWRAP observations. If time permits and if available, highlights from HIWRAP observations from the Hurricane Severe Storm Sentinel (HS3) field campaign in September 2012 will be presented.

  2. Physical function, grip strength and frailty in people living with HIV in sub-Saharan Africa: systematic review.

    Science.gov (United States)

    Bernard, Charlotte; Dabis, François; de Rekeneire, Nathalie

    2017-05-01

    To present the current knowledge on physical function, grip strength and frailty in HIV-infected patients living in sub-Saharan Africa, where the phenomenon is largely underestimated. A systematic search was conducted on MEDLINE, Scopus and African Index Medicus. We reviewed articles on sub-Saharan African people living with HIV (PLHIV) >18 years old, published until November 2016. Of 537 articles, 12 were conducted in six African countries and included in this review. Five articles reported information on functional limitation and one on disability. Two of these five articles reported functional limitation (low gait speed) in PLHIV. Disability was observed in 27% and 3% of PLHIV living in rural and urban places, respectively. Two of three studies reporting grip strength reported lower grip strength (nearly 4 kg) in PLHIV in comparison with uninfected patients. One study reported that PLHIV were more likely to be frail than HIV-uninfected individuals (19.4% vs. 13.3%), whereas another reported no statistical difference. Decline in physical function, grip strength and frailty are now part of the burden of PLHIV living in SSA countries, but current data are insufficient to characterise the real public health dimension of these impairments. Further studies are needed to depict this major public health challenge. As this is likely to contribute to a significant burden on the African healthcare systems and human resources in the near future, a holistic care approach should be developed to inform guidelines. © 2017 John Wiley & Sons Ltd.

  3. Using goal- and grip-related information for understanding the correctness of other's actions: an ERP study.

    Science.gov (United States)

    van Elk, Michiel; Bousardt, Roel; Bekkering, Harold; van Schie, Hein T

    2012-01-01

    Detecting errors in other's actions is of pivotal importance for joint action, competitive behavior and observational learning. Although many studies have focused on the neural mechanisms involved in detecting low-level errors, relatively little is known about error-detection in everyday situations. The present study aimed to identify the functional and neural mechanisms whereby we understand the correctness of other's actions involving well-known objects (e.g. pouring coffee in a cup). Participants observed action sequences in which the correctness of the object grasped and the grip applied to a pair of objects were independently manipulated. Observation of object violations (e.g. grasping the empty cup instead of the coffee pot) resulted in a stronger P3-effect than observation of grip errors (e.g. grasping the coffee pot at the upper part instead of the handle), likely reflecting a reorienting response, directing attention to the relevant location. Following the P3-effect, a parietal slow wave positivity was observed that persisted for grip-errors, likely reflecting the detection of an incorrect hand-object interaction. These findings provide new insight in the functional significance of the neurophysiological markers associated with the observation of incorrect actions and suggest that the P3-effect and the subsequent parietal slow wave positivity may reflect the detection of errors at different levels in the action hierarchy. Thereby this study elucidates the cognitive processes that support the detection of action violations in the selection of objects and grips.

  4. Stretch calculated from grip distance accurately approximates mid-specimen stretch in large elastic arteries in uniaxial tensile tests.

    Science.gov (United States)

    Tian, Lian; Henningsen, Joseph; Salick, Max R; Crone, Wendy C; Gunderson, McLean; Dailey, Seth H; Chesler, Naomi C

    2015-07-01

    The mechanical properties of vascular tissues affect hemodynamics and can alter disease progression. The uniaxial tensile test is a simple and effective method for determining the stress-strain relationship in arterial tissue ex vivo. To enable calculation of strain, stretch can be measured directly with image tracking of markers on the tissue or indirectly from the distance between the grips used to hold the specimen. While the imaging technique is generally considered more accurate, it also requires more analysis, and the grip distance method is more widely used. The purpose of this study is to compare the stretch of the testing specimen calculated from the grip distance method to that obtained from the imaging method for canine descending aortas and large proximal pulmonary arteries. Our results showed a significant difference in stretch between the two methods; however, this difference was consistently less than 2%. Therefore, the grip distance method is an accurate approximation of the stretch in large elastic arteries in the uniaxial tensile test. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. The Grip on the Handball – A Qualitative Analysis of the Influence of Materiality on Creativity in Sport

    DEFF Research Database (Denmark)

    Tanggaard, Lene; Laursen, Dan Nørgaard; Szulevicz, Thomas

    2015-01-01

    how balls made of synthetic polyurethane contribute to a better grip on the ball, which has led to new possibilities for attacking players in handball. The conclusion is that the leather handball is a mediating object, which co-creates the possibilities that the players have in expressing themselves...

  6. Constraints on grip selection in hemiparetic cerebral palsy: Effects of lesional side, end-point accuracy and context.

    NARCIS (Netherlands)

    Steenbergen, B.; Meulenbroek, R.G.J.; Rosenbaum, D.A.

    2004-01-01

    This study was concerned with the selection criteria used for grip planning in adolescents with left or right hemiparetic cerebral palsy. In the first experiment participants picked up a pencil and placed the tip in a pre-defined target region. We varied the size of the target to test the hypothesis

  7. Grip-Pattern Recognition in Smart Gun Based on Likelihood-Ratio Classifier and Support Vector Machine

    NARCIS (Netherlands)

    Shang, Xiaoxin; Veldhuis, Raymond N.J.

    2008-01-01

    In the biometric verification system of a smart gun, the rightful user of a gun is recognized based on grip-pattern recognition. It was found that the verification performance of this system degrades strongly when the data for training and testing have been recorded in different sessions with a time

  8. The Effect of Repetitive Rhythmic Precision Grip Task-Oriented Rehabilitation in Chronic Stroke Patients: A Pilot Study

    Science.gov (United States)

    Dispa, Delphine; Lejeune, Thierry; Thonnard, Jean-Louis

    2013-01-01

    Most chronic stroke patients present with difficulty in the manipulation of objects. The aim of this study was to test whether an intensive program of precision grip training could improve hand functioning of patients at more than 6 months after a stroke. This was a cross-over study; hence, at inclusion, the patients were randomly divided into two…

  9. The coefficient of variation as a measure of sincerity of effort of grip strength, Part II: sensitivity and specificity.

    Science.gov (United States)

    Shechtman, O

    2001-01-01

    The coefficient of variation (CV) is commonly used to detect sincerity of effort. The purpose of this study was to examine whether the CV possessed adequate sensitivity and specificity to effectively detect sincerity of effort of grip strength. One hundred forty-six uninjured volunteers underwent a series of grip strength tests. Sensitivity and specificity values were calculated for various CV cut-off values (between 2.5% and 22%) of the static grip test. The receiver operating characteristic (ROC) curves based on these values demonstrated the trade-offs between specificity and sensitivity. For example, the "traditional" 15% cut-off value yielded poor sensitivity (0.55), whereas the 11% cut-off value yielded poor specificity (0.74). Selecting any cut-off value along the continuum did not provide adequate sensitivity or specificity for labeling an effort sincere or insincere. Although the CV differentiated between maximal and submaximal effort, it was not sensitive or specific enough to do so effectively. Thus, the CV should not be used to assess sincerity of effort of grip strength.

  10. Synaptic and functional linkages between spinal premotor interneurons and hand-muscle activity during precision grip

    Directory of Open Access Journals (Sweden)

    Tomohiko eTakei

    2013-04-01

    Full Text Available Grasping is a highly complex movement that requires the coordination of a number of hand joints and muscles. Previous studies showed that spinal premotor interneurons (PreM-INs in the primate cervical spinal cord have divergent synaptic effects on hand motoneurons and that they might contribute to hand-muscle synergies. However, the extent to which these PreM-IN synaptic connections functionally contribute to modulating hand-muscle activity is not clear. In this paper, we explored the contribution of spinal PreM-INs to hand-muscle activation by quantifying the synaptic linkage (SL and functional linkage (FL of the PreM-INs with hand-muscle activities. The activity of 23 PreM-INs was recorded from the cervical spinal cord (C6–T1, with EMG signals measured simultaneously from hand and arm muscles in two macaque monkeys performing a precision grip task. Spike-triggered averages (STAs of rectified EMGs were compiled for 456 neuron–muscle pairs; 63 pairs showed significant post-spike effects (i.e., SL. Conversely, 231 of 456 pairs showed significant cross-correlations between the IN firing rate and rectified EMG (i.e., FL. Importantly, a greater proportion of the neuron–muscle pairs with SL showed FL (43/63 pairs, 68% compared with the pairs without SL (203/393, 52%, and the presence of SL was significantly associated with that of FL. However, a significant number of pairs had SL without FL (SL∩!FL, n = 20 or FL without SL (!SL∩FL, n = 203, and the proportions of these incongruities exceeded the number expected by chance. These results suggested that spinal PreM-INs function to significantly modulate hand-muscle activity during precision grip, but the contribution of other neural structures is also needed to recruit an adequate combination of hand-muscle motoneurons.

  11. Fabric along the NEEM ice core, Greenland, and its comparison with GRIP and NGRIP ice cores

    Science.gov (United States)

    Montagnat, M.; Azuma, N.; Dahl-Jensen, D.; Eichler, J.; Fujita, S.; Gillet-Chaulet, F.; Kipfstuhl, S.; Samyn, D.; Svensson, A.; Weikusat, I.

    2014-07-01

    Fabric (distribution of crystallographic orientations) along the full NEEM ice core, Greenland was measured in the field by an automatic ice texture analyzer every 10 m, from 33 m down to 2461 m depth. The fabric evolves from a slightly anisotropic fabric at the top, toward a strong single maximum at about 2300 m, which is typical of a deformation pattern mostly driven by uniaxial compression and simple shearing. A sharp increase in the fabric strengthening rate is observed at the Holocene to Wisconsin (HW) climatic transition. From a simple model we estimate that this depth is located at a transition from a state dominated by vertical compression to a state dominated by vertical shear. Comparisons are made to two others ice cores drilled along the same ridge; the GRIP ice core, drilled at the summit of the ice sheet, and the NGRIP ice core, drilled 325 km to the NNW of the summit along the ridge, and 365 km upstream from NEEM. This comparison tends to demonstrate that the ice viscosity change with the HW climatic transition must be associated with the shear-dominated state to induce the abrupt fabric strengthening observed at NEEM. This comparison therefore reflects the increasing role of shear deformation on the coring site when moving NW along the ridge from GRIP to NGRIP and NEEM. The difference in fabric profiles between NEEM and NGRIP also evidences a stronger lateral extension associated with a sharper ridge at NGRIP. Further along the core, centimeter scale abrupt texture (fabric and microstructure) variations are observed in the bottom part of the core. Their positions are in good agreement with the observed folding layers in Dahl-Jensen et al. (2013).

  12. Hand Grip Strength and Myocardial Oxygen Consumption Index among Coronary Artery Bypass Grafting Patients

    Directory of Open Access Journals (Sweden)

    Siti Nur Baait Biniti Mohd Sokran

    2015-07-01

    Full Text Available Background: Hand grip strength (HGS is a reliable indicator of peripheral muscle strength. Although, numerous studies have investigated the strength of hand grip; little attention has been given to coronary artery disease (CAD patients, exploring the relationship between HGS and myocardial oxygen consumption (MVO2 index. The current study aimed to evaluate the interaction between HGS and MVO2 index findings before and after cardiac surgery. Methods: Twenty-seven patients with CAD had HGS were assessed using handheld dynamometer. HGS for each hand were documented. MVO2 index was assessed using rate pressure product (RPP, which is the product of the heart rate (HR and systolic blood pressure (SBP. Repeated measures MANOVA were carried out to estimate the interaction between both hands HGS and MVO2 index before and after surgery. Results: There was significant interactions (P<0.001 for both HGS dominant and non-dominant with large effect sizes (HGS dominant×MVO2 index: hp2=0.44; HGS dominant×RPP: hp2=0.49. This signifies that peripheral muscle strength of the upper limb (HGS dominant and non-dominant had different effects on MVO2 index before and after surgery. The interaction graph shows that the increase in MVO2 index after surgery was significantly greater for peripheral muscle strength of the dominant hand when compared to non-dominant. Conclusion: Patients with CAD had interactions between HGS and oxygen consumption before and after surgery. Hence, HGS might be used as a predictor to assess oxygen consumption among cardiac patients.

  13. Multicentric observational study of pain after the use of a self-gripping lightweight mesh.

    Science.gov (United States)

    García Ureña, M Á; Hidalgo, M; Feliu, X; Velasco, M Á; Revuelta, S; Gutiérrez, R; Utrera, A; Porrero, J L; Marín, M; Zaragoza, C

    2011-10-01

    Investigation in the field of inguinal hernia surgery is now focused on postoperative pain. The extended use of lightweight meshes and alternative methods of fixation may play a relevant role in the reduction of pain. In this study, a new self-gripping lightweight polypropylene mesh is tested. A multicentric, observational study was scheduled to prospectively evaluate this new mesh. Ten centers agreed to participate. Only primary, type 1 or 2 uncomplicated hernias in adults were included. The mesh was placed as a Lichtenstein procedure without any fixation. A complete pain questionnaire was followed at 1 week, and at 1, 3 and 6 months postoperatively. The principal goal of the study was to evaluate maximum pain score at 6 months. Pain was assessed by a visual analog scale. A total of 256 patients were operated. Mean operative time was 35.6 min; 76.2% of patients were operated in an ambulatory setting. There were a few postoperative complications: 2 wound infections, 17 seromas, 21 hematomas, 6 orchitis. The incidence of acute pain was 27.3% at week 1 and 7.5% at month 1. The incidence of chronic pain was 3.6% at month 3 and 2.8% at month 6. No recurrences or long-term complications were observed. This self-gripping mesh can be used safely in type 1 and 2 primary, uncomplicated inguinal hernia with minimal morbidity and most patients under ambulatory setting. The registered incidence of chronic pain is lower than 3%.

  14. Scattering amplitudes in open superstring theory

    Energy Technology Data Exchange (ETDEWEB)

    Schlotterer, Oliver

    2011-07-15

    The present thesis deals with the theme field of the scattering amplitudes in theories of open superstrings. Especially two different formalisms for the handling of superstrings are introduced and applied for the calaculation of tree-level amplitudes - the Ramond- Neveu-Schwarz (RNS) and the Pure-Spinor (PS) formalism. The RNS approach is proved as flexible in order to describe compactification of the initially ten flat space-time dimensions to four dimensions. We solve the technical problems, which result from the interacting basing world-sheet theory with conformal symmetry. This is used to calculate phenomenologically relevant scattering amplitudes of gluons and quarks as well as production rates of massive harmonic vibrations, which were already identified as virtual exchange particles on the massless level. In the case of a low string mass scale in the range of some Tev the string-specific signatures in parton collisions can be observed in the near future in the LHC experiment at CERN and indicated as first experimental proof of the string theory. THose string effects occur universally for a wide class of string ground states respectively internal geometries and represent an elegant way to avoid the so-called landscape problem of the string theory. A further theme complex in this thesis is based on the PS formalism, which allows a manifestly supersymmetric treatment of scattering amplitudes in ten space-time dimension with sixteen supercharges. We introduce a family of superfields, which occur in massless amplitudes of the open string and can be naturally identified with diagrams of three-valued knots. Thereby we reach not only a compact superspace representation of the n-point field-theory amplitude but can also write the complete superstring n-point amplitude as minimal linear combination of partial amplitudes of the field theory as well as hypergeometric functions. The latter carry the string effects and are analyzed from different perspectives, above all

  15. Dynamic nonlinear focal shift in amplitude modulated moderately focused acoustic beams.

    Science.gov (United States)

    Jiménez, Noé; Camarena, Francisco; González-Salido, Nuria

    2017-03-01

    The phenomenon of the displacement of the position of the pressure, intensity and acoustic radiation force maxima along the axis of focused acoustic beams under increasing driving amplitudes (nonlinear focal shift) is studied for the case of a moderately focused beam excited with continuous and 25kHz amplitude modulated signals, both in water and tissue. We prove that in amplitude modulated beams the linear and nonlinear propagation effects coexist in a semi-period of modulation, giving place to a complex dynamic behavior, where the singular points of the beam (peak pressure, rarefaction, intensity and acoustic radiation force) locate at different points on axis as a function of time. These entire phenomena are explained in terms of harmonic generation and absorption during the propagation in a lossy nonlinear medium both for a continuous and an amplitude modulated beam. One of the possible applications of the acoustic radiation force displacement is the generation of shear waves at different locations by using a focused mono-element transducer excited by an amplitude modulated signal.

  16. Spinfoam cosmology with the proper vertex amplitude

    CERN Document Server

    Vilensky, Ilya

    2016-01-01

    The proper vertex amplitude is derived from the EPRL vertex by restricting to a single gravitational sector in order to achieve the correct semi-classical behaviour. We apply the proper vertex to calculate a cosmological transition amplitude that can be viewed as the Hartle-Hawking wavefunction. To perform this calculation we deduce the integral form of the proper vertex and use extended stationary phase methods to estimate the large-volume limit. We show that the resulting amplitude satisfies an operator constraint whose classical analogue is the Hamiltonian constraint of the Friedmann-Robertson-Walker cosmology. We find that the constraint dynamically selects the relevant family of coherent states and demonstrate a similar dynamic selection in standard quantum mechanics.

  17. A description of seismic amplitude techniques

    Science.gov (United States)

    Shadlow, James

    2014-02-01

    The acquisition of seismic data is a non-invasive technique used for determining the sub surface geology. Changes in lithology and fluid fill affect the seismic wavelet. Analysing seismic data for direct hydrocarbon indicators (DHIs), such as full stack amplitude anomalies, or amplitude variation with offset (AVO), can help a seismic interpreter relate the geophysical response to real geology and, more importantly, to distinguish the presence of hydrocarbons. Inversion is another commonly used technique that attempts to tie the seismic data back to the geology. Much has been written about these techniques, and attempting to gain an understanding on the theory and application of them by reading through various journals can be quite daunting. The purpose of this paper is to briefly outline DHI analysis, including full stack amplitude anomalies, AVO and inversion and show the relationship between all three. The equations presented have been included for completeness, but the reader can pass over the mathematical detail.

  18. Scattering Amplitudes and Worldsheet Models of QFTs

    CERN Document Server

    CERN. Geneva

    2016-01-01

    I will describe recent progress on the study of scattering amplitudes via ambitwistor strings and the scattering equations. Ambitwistor strings are worldsheet models of quantum field theories, inspired by string theory. They naturally lead to a representation of amplitudes based on the scattering equations. While worldsheet models and related ideas have had a wide-ranging impact on the modern study of amplitudes, their direct application at loop level is a very recent success. I will show how a major difficulty in the loop-level story, the technicalities of higher-genus Riemann surfaces, can be avoided by turning the higher-genus surface into a nodal Riemann sphere, with the nodes representing the loop momenta. I will present new formulas for the one-loop integrands of gauge theory and gravity, with or without supersymmetry, and also some two-loop results.

  19. Analytic representations of Yang-Mills amplitudes

    Science.gov (United States)

    Bjerrum-Bohr, N. E. J.; Bourjaily, Jacob L.; Damgaard, Poul H.; Feng, Bo

    2016-12-01

    Scattering amplitudes in Yang-Mills theory can be represented in the formalism of Cachazo, He and Yuan (CHY) as integrals over an auxiliary projective space-fully localized on the support of the scattering equations. Because solving the scattering equations is difficult and summing over the solutions algebraically complex, a method of directly integrating the terms that appear in this representation has long been sought. We solve this important open problem by first rewriting the terms in a manifestly Möbius-invariant form and then using monodromy relations (inspired by analogy to string theory) to decompose terms into those for which combinatorial rules of integration are known. The result is the foundations of a systematic procedure to obtain analytic, covariant forms of Yang-Mills tree-amplitudes for any number of external legs and in any number of dimensions. As examples, we provide compact analytic expressions for amplitudes involving up to six gluons of arbitrary helicities.

  20. Amplitude-modulated fiber-ring laser

    DEFF Research Database (Denmark)

    Caputo, J. G.; Clausen, Carl A. Balslev; Sørensen, Mads Peter

    2000-01-01

    Soliton pulses generated by a fiber-ring laser are investigated by numerical simulation and perturbation methods. The mathematical modeling is based on the nonlinear Schrödinger equation with perturbative terms. We show that active mode locking with an amplitude modulator leads to a self-starting......Soliton pulses generated by a fiber-ring laser are investigated by numerical simulation and perturbation methods. The mathematical modeling is based on the nonlinear Schrödinger equation with perturbative terms. We show that active mode locking with an amplitude modulator leads to a self......-starting of stable solitonic pulses from small random noise, provided the modulation depth is small. The perturbative analysis leads to a nonlinear coupled return map for the amplitude, phase, and position of the soliton pulses circulating in the fiber-ring laser. We established the validity of this approach...

  1. Speech production in amplitude-modulated noise

    DEFF Research Database (Denmark)

    Macdonald, Ewen N; Raufer, Stefan

    2013-01-01

    The Lombard effect refers to the phenomenon where talkers automatically increase their level of speech in a noisy environment. While many studies have characterized how the Lombard effect influences different measures of speech production (e.g., F0, spectral tilt, etc.), few have investigated...... the consequences of temporally fluctuating noise. In the present study, 20 talkers produced speech in a variety of noise conditions, including both steady-state and amplitude-modulated white noise. While listening to noise over headphones, talkers produced randomly generated five word sentences. Similar...... to previous studies, talkers raised the level of their voice in steady-state noise. While talkers also increased the level of their voice in amplitude-modulated noise, the increase was not as large as that observed in steady-state noise. Importantly, for the 2 and 4 Hz amplitude-modulated noise conditions...

  2. Amplitude-modulated fiber-ring laser

    DEFF Research Database (Denmark)

    Caputo, J. G.; Clausen, Carl A. Balslev; Sørensen, Mads Peter

    2000-01-01

    Soliton pulses generated by a fiber-ring laser are investigated by numerical simulation and perturbation methods. The mathematical modeling is based on the nonlinear Schrödinger equation with perturbative terms. We show that active mode locking with an amplitude modulator leads to a self-starting......Soliton pulses generated by a fiber-ring laser are investigated by numerical simulation and perturbation methods. The mathematical modeling is based on the nonlinear Schrödinger equation with perturbative terms. We show that active mode locking with an amplitude modulator leads to a self......-starting of stable solitonic pulses from small random noise, provided the modulation depth is small. The perturbative analysis leads to a nonlinear coupled return map for the amplitude, phase, and position of the soliton pulses circulating in the fiber-ring laser. We established the validity of this approach...

  3. On Arbitrary Phases in Quantum Amplitude Amplification

    CERN Document Server

    Hoyer, P

    2000-01-01

    We consider the use of arbitrary phases in quantum amplitude amplification which is a generalization of quantum searching. We prove that the phase condition in amplitude amplification is given by $\\tan(\\phi/2)=\\tan(\\phi/2)(1-2a)$, where $\\phi$ and $\\phi$ are the phases used and where $a$ is the success probability of the given algorithm. Thus the choice of phases depends nontrivially and nonlinearly on the success probability. Utilizing this condition, we give methods for constructing quantum algorithms that succeed with certainty and for implementing arbitrary rotations. We also conclude that phase errors of order up to $\\frac{1}{\\sqrt{a}}$ can be tolerated in amplitude amplification.

  4. Nonlinear (Super)Symmetries and Amplitudes

    CERN Document Server

    Kallosh, Renata

    2016-01-01

    There is an increasing interest in nonlinear supersymmetries in cosmological model building. Independently, elegant expressions for the all-tree amplitudes in models with nonlinear symmetries, like D3 brane Dirac-Born-Infeld-Volkov-Akulov theory, were recently discovered. Using the generalized background field method we show how, in general, nonlinear symmetries of the action, bosonic and fermionic, constrain amplitudes beyond soft limits. The same identities control, for example, bosonic E_{7(7)} scalar sector symmetries as well as the fermionic goldstino symmetries. We present a universal derivation of the vanishing amplitudes in the single (bosonic or fermionic) soft limit. We explain why, universally, the double-soft limit probes the coset space algebra. We also provide identities describing the multiple-soft limit. We discuss loop corrections to N\\geq 5 supergravity, to the D3 brane, and the UV completion of constrained multiplets in string theory.

  5. Analytic Representations of Yang-Mills Amplitudes

    CERN Document Server

    Bjerrum-Bohr, N E J; Damgaard, Poul H; Feng, Bo

    2016-01-01

    Scattering amplitudes in Yang-Mills theory can be represented in the formalism of Cachazo, He and Yuan (CHY) as integrals over an auxiliary projective space---fully localized on the support of the scattering equations. Because solving the scattering equations is difficult and summing over the solutions algebraically complex, a method of directly integrating the terms that appear in this representation has long been sought. We solve this important open problem by first rewriting the terms in a manifestly Mobius-invariant form and then using monodromy relations (inspired by analogy to string theory) to decompose terms into those for which combinatorial rules of integration are known. The result is a systematic procedure to obtain analytic, covariant forms of Yang-Mills tree-amplitudes for any number of external legs and in any number of dimensions. As examples, we provide compact analytic expressions for amplitudes involving up to six gluons of arbitrary helicities.

  6. Modified π π amplitude with σ pole

    Science.gov (United States)

    Bydžovský, P.; Kamiński, R.; Nazari, V.

    2014-12-01

    A set of well-known once subtracted dispersion relations with imposed crossing symmetry condition is used to modify unitary multichannel S (π π , K K ¯, and η η ) and P (π π , ρ 2 π , and ρ σ ) wave amplitudes mostly below 1 GeV. Before the modifications, these amplitudes significantly did not satisfy the crossing symmetry condition and did not describe the π π threshold region. Moreover, the pole of the S wave amplitude related with the f0(500 ) meson (former f0(600 ) or σ ) had much smaller imaginary part and bigger real one in comparison with those in the newest Particle Data Group Tables. Here, these amplitudes are supplemented by near threshold expansion polynomials and refitted to the experimental data in the effective two pion mass from the threshold to 1.8 GeV and to the dispersion relations up to 1.1 GeV. In result the self consistent, i.e., unitary and fulfilling the crossing symmetry condition, S and P wave amplitudes are formed and the σ pole becomes much narrower and lighter. To eliminate doubts about the uniqueness of the so obtained sigma pole position short and purely mathematical proof of the uniqueness of the results is also presented. This analysis is addressed to a wide group of physicists and aims at providing a very effective and easy method of modification of, many presently used, π π amplitudes with a heavy and broad σ meson without changing of their original mathematical structure.

  7. Gluon scattering amplitudes at strong coupling

    Energy Technology Data Exchange (ETDEWEB)

    Alday, Luis F. [Institute for Theoretical Physics and Spinoza Institute, Utrecht University, 3508 TD Utrecht (Netherlands); Maldacena, Juan [School of Natural Sciences, Institute for Advanced Study, Princeton, NJ 08540 (United States)

    2007-06-15

    We describe how to compute planar gluon scattering amplitudes at strong coupling in N = 4 super Yang Mills by using the gauge/string duality. The computation boils down to finding a certain classical string configuration whose boundary conditions are determined by the gluon momenta. The results are infrared divergent. We introduce the gravity version of dimensional regularization to define finite quantities. The leading and subleading IR divergencies are characterized by two functions of the coupling that we compute at strong coupling. We compute also the full finite form for the four point amplitude and we find agreement with a recent ansatz by Bern, Dixon and Smirnov.

  8. Topographic quantitative EEG amplitude in recovered alcoholics.

    Science.gov (United States)

    Pollock, V E; Schneider, L S; Zemansky, M F; Gleason, R P; Pawluczyk, S

    1992-05-01

    Topographic measures of electroencephalographic (EEG) amplitude were used to compare recovered alcoholics (n = 14) with sex- and age-matched control subjects. Delta, alpha, and beta activity did not distinguish the groups, but regional differences in theta distribution did. Recovered alcoholics showed more uniform distributions of theta amplitudes in bilateral anterior and posterior regions compared with controls. Because a minimum of 5 years had elapsed since the recovered alcoholic subjects fulfilled DSM-III-R criteria for alcohol abuse or dependence, it is unlikely these EEG theta differences reflect the effects of withdrawal.

  9. Amplitude Models for Discrimination and Yield Estimation

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, William Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-09-01

    This seminar presentation describes amplitude models and yield estimations that look at the data in order to inform legislation. The following points were brought forth in the summary: global models that will predict three-component amplitudes (R-T-Z) were produced; Q models match regional geology; corrected source spectra can be used for discrimination and yield estimation; three-component data increase coverage and reduce scatter in source spectral estimates; three-component efforts must include distance-dependent effects; a community effort on instrument calibration is needed.

  10. Fatigue Reliability under Multiple-Amplitude Loads

    DEFF Research Database (Denmark)

    Talreja, R.

    1979-01-01

    A method to determine the fatigue of structures subjected to multiple-amplitude loads is presented. Unlike the more common cumulative damage methods, which are usually based on fatigue life data, the proposed method is based on tensile strength data. Assuming the Weibull distribution...... for the initial tensile strength and the fatigue life, the probability distributions for the residual tensile strength in both the crack initiation and the crack propagation stages of fatigue are determined. The method is illustrated for two-amplitude loads by means of experimental results obtained by testing...

  11. Probability amplitude in quantum like games

    CERN Document Server

    Grib, A A; Starkov, K

    2003-01-01

    Examples of games between two partners with mixed strategies, calculated by the use of the probability amplitude are given. The first game is described by the quantum formalism of spin one half system for which two noncommuting observables are measured. The second game corresponds to the spin one case. Quantum logical orthocomplemented nondistributive lattices for these two games are presented. Interference terms for the probability amplitudes are analyzed by using so called contextual approach to probability (in the von Mises frequency approach). We underline that our games are not based on using of some microscopic systems. The whole scenario is macroscopic.

  12. Singularity Structure of Maximally Supersymmetric Scattering Amplitudes

    DEFF Research Database (Denmark)

    Arkani-Hamed, Nima; Bourjaily, Jacob L.; Cachazo, Freddy

    2014-01-01

    We present evidence that loop amplitudes in maximally supersymmetric (N=4) Yang-Mills theory (SYM) beyond the planar limit share some of the remarkable structures of the planar theory. In particular, we show that through two loops, the four-particle amplitude in full N=4 SYM has only logarithmic ...... singularities and is free of any poles at infinity—properties closely related to uniform transcendentality and the UV finiteness of the theory. We also briefly comment on implications for maximal (N=8) supergravity theory (SUGRA)....

  13. New structures in scattering amplitudes: A review

    Science.gov (United States)

    Benincasa, Paolo

    2014-02-01

    We review some recent developments in the understanding of field theories in the perturbative regime. In particular, we discuss the notions of analyticity, unitarity and locality, and therefore the singularity structure of scattering amplitudes in general interacting theories. We describe their tree-level structure and their on-shell representations, as well as the links between the tree-level structure itself and the structure of the loop amplitudes. Finally, we describe the on-shell diagrammatics recently proposed both on general grounds and in the remarkable example of planar supersymmetric theories.

  14. Amplitude ratios in ρ0 leptoproductions and GPDs

    Directory of Open Access Journals (Sweden)

    Goloskokov S.V.

    2017-01-01

    Using the model results we calculate the ratio of different helicity amplitudes for a transversely polarized proton target to the leading twist longitudinal amplitude. Our results are close to the amplitude ratios measured by HERMES.

  15. Effect Of Vibration Amplitude Level On Seated Occupant Reaction Time

    National Research Council Canada - National Science Library

    Amzar Azizan; Ratchaphon Ittianuwat; Zhengqing Liu

    2015-01-01

    ... r.m.s for each volunteer. Seated volunteers were exposed to Gaussian random vibration with frequency band 1-15 Hz at two level of amplitude low vibration amplitude and medium vibration amplitude for 20-minutes in separate days...

  16. Microwave Imaging using Amplitude-only Data

    DEFF Research Database (Denmark)

    Rubæk, Tonny; Zhurbenko, Vitaliy

    2010-01-01

    This paper discuss how the performance of an imaging system is affected when the phase information of the measurements are removed from the data, leaving only amplitude information as input for the imaging algorithm. Simulated data are used for this purpose, and the images resulting from using am...

  17. Connected formulas for amplitudes in standard model

    Science.gov (United States)

    He, Song; Zhang, Yong

    2017-03-01

    Witten's twistor string theory has led to new representations of S-matrix in massless QFT as a single object, including Cachazo-He-Yuan formulas in general and connected formulas in four dimensions. As a first step towards more realistic processes of the standard model, we extend the construction to QCD tree amplitudes with massless quarks and those with a Higgs boson. For both cases, we find connected formulas in four dimensions for all multiplicities which are very similar to the one for Yang-Mills amplitudes. The formula for quark-gluon color-ordered amplitudes differs from the pure-gluon case only by a Jacobian factor that depends on flavors and orderings of the quarks. In the formula for Higgs plus multi-parton amplitudes, the massive Higgs boson is effectively described by two additional massless legs which do not appear in the Parke-Taylor factor. The latter also represents the first twistor-string/connected formula for form factors.

  18. Audio steganography by amplitude or phase modification

    Science.gov (United States)

    Gopalan, Kaliappan; Wenndt, Stanley J.; Adams, Scott F.; Haddad, Darren M.

    2003-06-01

    This paper presents the results of embedding short covert message utterances on a host, or cover, utterance by modifying the phase or amplitude of perceptually masked or significant regions of the host. In the first method, the absolute phase at selected, perceptually masked frequency indices was changed to fixed, covert data-dependent values. Embedded bits were retrieved at the receiver from the phase at the selected frequency indices. Tests on embedding a GSM-coded covert utterance on clean and noisy host utterances showed no noticeable difference in the stego compared to the hosts in speech quality or spectrogram. A bit error rate of 2 out of 2800 was observed for a clean host utterance while no error occurred for a noisy host. In the second method, the absolute phase of 10 or fewer perceptually significant points in the host was set in accordance with covert data. This resulted in a stego with successful data retrieval and a slightly noticeable degradation in speech quality. Modifying the amplitude of perceptually significant points caused perceptible differences in the stego even with small changes of amplitude made at five points per frame. Finally, the stego obtained by altering the amplitude at perceptually masked points showed barely noticeable differences and excellent data recovery.

  19. Hyperlogarithms and periods in Feynman amplitudes

    CERN Document Server

    Todorov, Ivan

    2016-01-01

    The role of hyperlogarithms and multiple zeta values (and their generalizations) in Feynman amplitudes is being gradually recognized since the mid 1990's. The present lecture provides a concise introduction to a fast developing subjects that attracts the attention to a wide range of specialists - from number theorists to particle physicists.

  20. Polynomial structures in one-loop amplitudes

    NARCIS (Netherlands)

    Britto, R.; Feng, B.; Yang, G.

    2008-01-01

    A general one-loop scattering amplitude may be expanded in terms of master integrals. The coefficients of the master integrals can be obtained from tree-level input in a two-step process. First, use known formulas to write the coefficients of (4-2epsilon)-dimensional master integrals; these formulas

  1. Integral coefficients for one-loop amplitudes

    NARCIS (Netherlands)

    Britto, R.; Feng, B.

    2008-01-01

    We present a set of algebraic functions for evaluating the coefficients of the scalar integral basis of a general one-loop amplitude. The functions are derived from unitarity cuts, but the complete cut-integral procedure has been carried out in generality so that it never needs to be repeated. Where

  2. Amplitude Correction Factors of KVN Observations

    CERN Document Server

    Lee, Sang-Sung; Oh, Chung Sik; Kim, Hyo Ryoung; Kim, Jongsoo; Jung, Taehyun; Oh, Se-Jin; Roh, Duk-Gyoo; Jung, Dong-Kyu; Yeom, Jae-Hwan

    2015-01-01

    We report results of investigation of amplitude calibration for very long baseline interferometry (VLBI) observations with Korean VLBI Network (KVN). Amplitude correction factors are estimated based on comparison of KVN observations at 22~GHz correlated by Daejeon hardware correlator and DiFX software correlator in Korea Astronomy and Space Science Institute (KASI) with Very Long Baseline Array (VLBA) observations at 22~GHz by DiFX software correlator in National Radio Astronomy Observatory (NRAO). We used the observations for compact radio sources, 3C~454.3 and NRAO~512, which are almost unresolved for baselines in a range of 350-477~km. Visibility data of the sources obtained with similar baselines at KVN and VLBA are selected, fringe-fitted, calibrated, and compared for their amplitudes. We found that visibility amplitudes of KVN observations should be corrected by factors of 1.10 and 1.35 when correlated by DiFX and Daejeon correlators, respectively. These correction factors are attributed to the combinat...

  3. Holographic corrections to the Veneziano amplitude

    Science.gov (United States)

    Armoni, Adi; Ireson, Edwin

    2017-08-01

    We propose a holographic computation of the 2 → 2 meson scattering in a curved string background, dual to a QCD-like theory. We recover the Veneziano amplitude and compute a perturbative correction due to the background curvature. The result implies a small deviation from a linear trajectory, which is a requirement of the UV regime of QCD.

  4. The CMU Baryon Amplitude Analysis Program

    Science.gov (United States)

    Bellis, Matt

    2007-05-01

    The PWA group at Carnegie Mellon University has developed a comprehensive approach and analysis package for the purpose of extracting the amplitudes for photoproduced baryon resonances. The end goal is to identify any missing resonances that are predicted by the constituent quark model, but not definitively observed in experiments. The data comes from the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab.

  5. Generalised Unitarity for Dimensionally Regulated Amplitudes

    CERN Document Server

    Bobadilla, W J Torres; Mastrolia, P; Mirabella, E

    2015-01-01

    We present a novel set of Feynman rules and generalised unitarity cut-conditions for computing one-loop amplitudes via d-dimensional integrand reduction algorithm. Our algorithm is suited for analytic as well as numerical result, because all ingredients turn out to have a four-dimensional representation. We will apply this formalism to NLO QCD corrections.

  6. Consonant confusions in amplitude-expanded speech.

    Science.gov (United States)

    Freyman, R L; Nerbonne, G P

    1996-12-01

    The perceptual consequences of expanding the amplitude variations in speech were studied under conditions in which spectral information was obscured by signal correlated noise that had an envelope correlated with the speech envelope, but had a flat amplitude spectrum. The noise samples, created individually from 22 vowel-consonant-vowel nonsense words, were used as maskers of those words, with signal-to-noise ratios ranging from -15 to 0 dB. Amplitude expansion was by a factor of 3.0 in terms of decibels. In the first experiment, presentation level for speech peaks was 80 dB SPL. Consonant recognition performance for expanded speech by 50 listeners with normal hearing was as much as 30 percentage points poorer than for unexpanded speech and the types of errors were dramatically different, especially in the midrange of S-N ratios. In a second experiment presentation level was varied to determine whether reductions in consonant levels produced by expansion were responsible for the differences between conditions. Recognition performance for unexpanded speech at 40 dB SPL was nearly equivalent to that for expanded speech at 80 dB SPL. The error patterns obtained in these two conditions were different, suggesting that the differences between conditions in Experiment 1 were due largely to expanded amplitude envelopes rather than differences in audibility.

  7. Microwave Imaging using Amplitude-only Data

    DEFF Research Database (Denmark)

    Rubæk, Tonny; Zhurbenko, Vitaliy

    2010-01-01

    This paper discuss how the performance of an imaging system is affected when the phase information of the measurements are removed from the data, leaving only amplitude information as input for the imaging algorithm. Simulated data are used for this purpose, and the images resulting from using am...

  8. Particle Distribution Modification by Low Amplitude Modes

    Energy Technology Data Exchange (ETDEWEB)

    White, R. B.; Gorelenkov, N.; Heidbrink, W. W.; Van Zeeland, M. A.

    2009-08-28

    Modification of a high energy particle distribution by a spectrum of low amplitude modes is investigated using a guiding center code. Only through resonance are modes effective in modifying the distribution. Diagnostics are used to illustrate the mode-particle interaction and to find which effects are relevant in producing significant resonance, including kinetic Poincare plots and plots showing those orbits with time averaged mode-particle energy transfer. Effects of pitch angle scattering and drag are studied, as well as plasma rotation and time dependence of the equilibrium and mode frequencies. A specific example of changes observed in a DIII-D deuterium beam distribution in the presence of low amplitude experimentally validated Toroidal Alfven (TAE) eigenmodes and Reversed Shear Alfven (RSAE) eigenmodes is examined in detail. Comparison with experimental data shows that multiple low amplitude modes can account for significant modification of high energy beam particle distributions. It is found that there is a stochastic threshold for beam profile modification, and that the experimental amplitudes are only slightly above this threshold.

  9. Stora's fine notion of divergent amplitudes

    Directory of Open Access Journals (Sweden)

    Joseph C. Várilly

    2016-11-01

    Full Text Available Stora and coworkers refined the notion of divergent quantum amplitude, somewhat upsetting the standard power-counting recipe. This unexpectedly clears the way to new prototypes for free and interacting field theories of bosons of any mass and spin.

  10. Taming Tree Amplitudes In General Relativity

    CERN Document Server

    Benincasa, Paolo; Cachazo, Freddy; 10.1088/1126-6708/2007/11/057

    2008-01-01

    We give a proof of BCFW recursion relations for all tree-level amplitudes of gravitons in General Relativity. The proof follows the same basic steps as in the BCFW construction and it is an extension of the one given for next-to-MHV amplitudes by one of the authors and P. Svr\\v{c}ek in hep-th/0502160. The main obstacle to overcome is to prove that deformed graviton amplitudes vanish as the complex variable parameterizing the deformation is taken to infinity. This step is done by first proving an auxiliary recursion relation where the vanishing at infinity follows directly from a Feynman diagram analysis. The auxiliary recursion relation gives rise to a representation of gravity amplitudes where the vanishing under the BCFW deformation can be directly proven. Since all our steps are based only on Feynman diagrams, our proof completely establishes the validity of BCFW recursion relations. This means that many results in the literature that were derived assuming their validity become true statements.

  11. Taming tree amplitudes in general relativity

    Science.gov (United States)

    Benincasa, Paolo; Boucher-Veronneau, Camille; Cachazo, Freddy

    2007-11-01

    We give a proof of BCFW recursion relations for all tree-level amplitudes of gravitons in General Relativity. The proof follows the same basic steps as in the BCFW construction and it is an extension of the one given for next-to-MHV amplitudes by one of the authors and P. Svrcek in hep-th/0502160. The main obstacle to overcome is to prove that deformed graviton amplitudes vanish as the complex variable parameterizing the deformation is taken to infinity. This step is done by first proving an auxiliary recursion relation where the vanishing at infinity follows directly from a Feynman diagram analysis. The auxiliary recursion relation gives rise to a representation of gravity amplitudes where the vanishing under the BCFW deformation can be directly proven. Since all our steps are based only on Feynman diagrams, our proof completely establishes the validity of BCFW recursion relations. This means that many results in the literature that were derived assuming their validity become true statements.

  12. Reconstructing the distributed force on an atomic force microscope cantilever

    Science.gov (United States)

    Wagner, Ryan; Killgore, Jason

    2017-03-01

    A methodology is developed to reconstruct the force applied to an atomic force microscopy (AFM) cantilever given the shape in which it vibrates. This is accomplished by rewriting Bernoulli–Euler beam theory such that the force on the cantilever is approximated as a linear superposition of the theoretical cantilever eigenmodes. The weighting factors in this summation are calculated from the amplitude and phase measured along the length of the cantilever. The accuracy of the force reconstruction is shown to depend on the frequency at which the measurement is performed, the number of discrete points measured along the length of the cantilever, and the signal-to-noise ratio of the measured signal. In contrast to other AFM force reconstruction techniques, this method can reconstruct the distribution of force applied over the length of the AFM cantilever. However, this method performs poorly for localized forces applied to the cantilever, such as is typical of most tip–sample interaction forces. Proof of concept experiments are performed on an electrostatically excited cantilever and the expected force distribution is recovered. This force reconstruction technique offers previously unavailable insight into the distributed forces experienced by an AFM cantilever.

  13. ABJM amplitudes and the positive orthogonal Grassmannian

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Yu-tin [School of Natural Sciences, Institute for Advanced Study,Princeton, NJ 08540 (United States); Wen, CongKao [Centre for Research in String Theory, Department of Physics,Queen Mary University of London, Mile End Road, London E1 4NS (United Kingdom)

    2014-02-25

    A remarkable connection between perturbative scattering amplitudes of four dimensional planar SYM, and the stratification of the positive Grassmannian, was revealed in the seminal work of Arkani-Hamed et al. Similar extension for three-dimensional ABJM theory was proposed. Here we establish a direct connection between planar scattering amplitudes of ABJM theory, and singularities thereof, to the stratification of the positive orthogonal Grassmannian. In particular, scattering processes are constructed through on-shell diagrams, which are simply iterative gluing of the fundamental four-point amplitude. Each diagram is then equivalent to the merging of fundamental OG{sub 2} orthogonal Grassmannian to form a larger OG{sub k}, where 2k is the number of external particles. The invariant information that is encoded in each diagram is precisely this stratification. This information can be easily read off via permutation paths of the on-shell diagram, which also can be used to derive a canonical representation of OG{sub k} that manifests the vanishing of consecutive minors as the singularity of all on-shell diagrams. Quite remarkably, for the BCFW recursion representation of the tree-level amplitudes, the on-shell diagram manifests the presence of all physical factorization poles, as well as the cancellation of the spurious poles. After analytically continuing the orthogonal Grassmannian to split signature, we reveal that each on-shell diagram in fact resides in the positive cell of the orthogonal Grassmannian, where all minors are positive. In this language, the amplitudes of ABJM theory is simply an integral of a product of dlog forms, over the positive orthogonal Grassmannian.

  14. Scaling of motor cortical excitability during unimanual force generation.

    Science.gov (United States)

    Perez, Monica A; Cohen, Leonardo G

    2009-10-01

    During performance of a unimanual force generation task primary motor cortices (M1s) experience clear functional changes. Here, we evaluated the way in which M1s interact during parametric increases in right wrist flexion force in healthy volunteers. We measured the amplitude and the slope of motor evoked potentials (MEP) recruitment curves to transcranial magnetic stimulation (TMS) in the left and right flexor carpi radialis (FCR) muscles at rest and during 10%, 30% and 70% of maximal wrist flexion force. At rest, no differences were observed in the amplitude and slope of MEP recruitment curves in the left and right FCR muscles. With increasing right wrist flexion force, MEP amplitudes increased in both FCR muscles, with larger amplitudes in the right FCR. We found a significant correlation between the left and right MEP amplitudes across conditions. The slope of right and left FCR MEP recruitment curve was significantly steeper at 70% of force compared to rest and 10% of force. A significant correlation between the slope of left and right FCR MEP amplitudes was found at 70% of force only. Our results indicate a differential scaling of excitability in the corticospinal system controlling right and left FCR muscles at increasing levels of unimanual force generation. Specifically, these data highlights that at strong levels of unimanual force the increases in motor cortical excitability with increasing TMS stimulus intensities follow a similar pattern in both M1s, while at low levels of force they do not.

  15. The influence of respiratory acid-base changes on muscle performance and excitability of the sarcolemma during strenuous intermittent hand grip exercise.

    Science.gov (United States)

    Hilbert, M; Shushakov, V; Maassen, N

    2012-02-01

    Acidification has been reported to provide protective effects on force production in vitro. Thus, in this study, we tested if respiratory acid-base changes influence muscle function and excitability in vivo. Nine subjects performed strenuous, intermittent hand grip exercises (10 cycles of 15 s of work/45 s of rest) under respiratory acidosis by CO(2) rebreathing, alkalosis by hyperventilation, or control. The Pco(2), pH, K(+) concentration ([K(+)]), and Na(+) concentration were measured in venous and arterialized blood. Compound action potentials (M-wave) were elicited to examine the excitability of the sarcolemma. The surface electromyogram (EMG) was recorded to estimate the central drive to the muscle. The lowest venous pH during the exercise period was 7.24 ± 0.03 in controls, 7.31 ± 0.05 with alkalosis, and 7.17 ± 0.04 with acidosis (P acidosis than with alkalosis, and, after the second cycle, it was smaller with acidosis than with the control condition (P Respiratory alkalosis stabilized the M-wave area without influencing performance. Thus, we did not find a direct link between performance and alteration of excitability of the sarcolemma due to changes in pH in vivo.

  16. The development of a methodology to determine the relationship in grip size and pressure to racket head speed in a tennis forehand stroke

    DEFF Research Database (Denmark)

    Christensen, Jonas; Rasmussen, John; Halkon, Ben;

    2016-01-01

    This study developed a methodology to examine the effects of grip size and grip firmness on the kinematic contribution of angular velocity (KCAV) to the generation of racket head speed during a topspin tennis forehand. The KCAV is subdivided into kinematic contribution of joint angular velocity...... and kinematic contribution of the body segments in the upper trunk translational and angular velocities. Two Babolat Pure Storm GT rackets, with grip sizes 2 and 4 respectively, were used with Tekscan 9811E pressure sensors applied to the handles to examine pressure distribution during the stroke. Upper body...

  17. Finite-amplitude steady waves in plane viscous shear flows

    Science.gov (United States)

    Milinazzo, F. A.; Saffman, P. G.

    1985-01-01

    Computations of two-dimensional solutions of the Navier-Stokes equations are carried out for finite-amplitude waves on steady unidirectional flow. Several cases are considered. The numerical method employs pseudospectral techniques in the streamwise direction and finite differences on a stretched grid in the transverse direction, with matching to asymptotic solutions when unbounded. Earlier results for Poiseuille flow in a channel are re-obtained, except that attention is drawn to the dependence of the minimum Reynolds number on the physical constraint of constant flux or constant pressure gradient. Attempts to calculate waves in Couette flow by continuation in the velocity of a channel wall fail. The asymptotic suction boundary layer is shown to possess finite-amplitude waves at Reynolds numbers orders of magnitude less than the critical Reynolds number for linear instability. Waves in the Blasius boundary layer and unsteady Rayleigh profile are calculated by employing the artifice of adding a body force to cancel the spatial or temporal growth. The results are verified by comparison with perturbation analysis in the vicinity of the linear-instability critical Reynolds numbers.

  18. New insights on the anatomy of abrupt climate changes based on high-resolution ice core records from NorthGRIP (Greenland)

    Science.gov (United States)

    Capron, E.; Rasmussen, S.; Popp, T. J.; Vaughn, B. H.; Gkinis, V.; Erhardt, T.; Fischer, H.; Blunier, T.; Landais, A.; Pedro, J. B.; Steffensen, J. P.; Svensson, A.; Vinther, B.

    2016-12-01

    The millennial-scale succession of Greenland Stadials (GS) and Greenland Interstadials (GI) illustrates the Greenland expression of the well-known sequence of Dansgaard-Oeschger (DO) events, within which we observe additional climate variations of decadal to centennial-scale duration. Various paradigms, mostly based on interactions between the cryosphere and the ocean, have been proposed to explain the existence and evolution of DO events. Annual to decadal scale records of environmental and climatic regional changes over the rapid transitions are needed to assess whether climate model outputs based on a particular mechanism are consistent with the observed spatial pattern and temporal phasing. Here we present new multiannual resolution stable water isotope measurements (ice δ18O and δD) and annually resolved ion chemistry records from the NorthGRIP ice core. Because these tracers imprint the signatures of different parts of the Northern Hemisphere climate system, we can map the anatomy - the spatial and temporal signature of climate and environmental changes - associated with abrupt transitions (from GS to GI and vice-versa) occurring during Marine Isotopic Stage (MIS) 4. We determine via a statistical approach the timing and duration of the transitions, along with the amplitude of the local and regional changes associated with each Greenland warming and cooling phase. We quantify similarities and differences in the sequences of events through a comparison with results obtained for MIS 3 abrupt transitions and results from the NEEM ice core for selected transitions. The anatomy of abrupt climate changes appears to be different from one event to the next, suggesting that the mechanisms at play are not identical for all of them. We discuss the possible influence of (1) the Heinrich Stadials (i.e. GS during which a Heinrich Event occurred) and of (2) the long term evolution of the climate system on the different decadal to centennial-scale sequences of events

  19. A single magnetic nanocomposite cilia force sensor

    KAUST Repository

    Alfadhel, Ahmed

    2016-04-20

    The advancements in fields like robotics and medicine continuously require improvements of sensor devices and more engagement of cooperative sensing technologies. For example, instruments such as tweezers with sensitive force sensory heads could provide the ability to sense a variety of physical quantities in real time, such as the amount and direction of the force applied or the texture of the gripped object. Force sensors with such abilities could be great solutions toward the development of smart surgical tools. In this work, a unique force sensor that can be integrated at the tips of robotic arms or surgical tools is reported. The force sensor consists of a single bioinspired, permanent magnetic and highly elastic nanocomposite cilia integrated on a magnetic field sensing element. The nanocomposite is prepared from permanent magnetic nanowires incorporated into the highly elastic polydimethylsiloxane. We demonstrate the potential of this concept by performing several experiments to show the performance of the force sensor. The developed sensor element has a 200 μm in diameter single cilium with 1:5 aspect ratio and shows a detection range up to 1 mN with a sensitivity of 1.6 Ω/mN and a resolution of 31 μN. The simple fabrication process of the sensor allows easy optimization of the sensor performance to meet the needs of different applications.

  20. Development and precision position/force control of a new flexure-based microgripper

    Science.gov (United States)

    Yang, Yi-ling; Wei, Yan-ding; Lou, Jun-qiang; Xie, Feng-ran; Fu, Lei

    2016-01-01

    This paper presents the design, modeling and position/force control of a new piezo-driven microgripper with integrated position and force sensors. The structural design of the microgripper is based on double amplification mechanisms employing the bridge-type mechanism and the parallelogram mechanism. The microgripper can generate a large gripping range and pure translation of the gripping arm. Through the pseudorigid-body-model method, theoretical models are derived. By means of several finite-element analysis simulations, the optimal structural parameters for the microgripper are acquired and the theoretical models are analyzed and validated. Furthermore, to improve the performance of the microgripper, a new hybrid position/force control scheme employing a nonlinear fuzzy logic controller combined with an incremental proportional-integral controller is presented. The control scheme is capable of regulating the position and the gripping force of the microgripper simultaneously. Experimental investigation and validation were performed and the experimental results verify the effectiveness of the developed structural design and the proposed hybrid control scheme.

  1. Design of a microelectromechanical systems microgripper with integrated electrothermal actuator and force sensor

    Directory of Open Access Journals (Sweden)

    Sijie Yang

    2016-10-01

    Full Text Available This article presents the conceptual design of a novel compliant microelectromechanical systems (MEMS-based gripper with integrated electrothermal actuator and electrothermal force sensor. By this design solution, the device possesses some unique characteristics including a small and compact footprint size, and a large driving force by the thermal actuator. Owing to the use of a compliant rotational bearing, a large gripping range is obtained. The sensing arm has a capability of detecting the force transmitted from the left arm so as to prevent the damage of the grasped object. Analytical models are developed to evaluate the statics and dynamics performance of the gripper. Simulation results show that the thermal actuator produces sufficient gripping force to execute the gripping operation with a range of 80 µm under a low input voltage of 6 V. Moreover, the results of the established theoretical models match well with the finite element analysis (FEA simulation results, which verifies the feasibility of the proposed gripper design.

  2. Role of attractive forces in tapping tip force microscopy

    DEFF Research Database (Denmark)

    Kyhle, Anders; Sørensen, Alexis Hammer; Bohr, Jakob

    1997-01-01

    We present experimental and numerical results demonstrating the drastic influence of attractive forces on the behaviour of the atomic force microscope when operated in the resonant tapping tip mode in an ambient environment. It is often assumed that tapping is related to repulsive interaction....... In contrast, we find that in general the attractive forces are the most dominant interaction in this mode of operation. We show that attractive forces in combination with the repulsive elastic type of forces cause points of instability in the parameter space constituted by: the cantilever swing amplitude......, the frequency bias point, and the distance between the fixed end of the cantilever and the sample. These points of instability can result in disturbances during image acquisition on hard elastic surfaces. ©1997 American Institute of Physics....

  3. Amplitude Equations for Electrostatic Waves multiple species

    CERN Document Server

    Crawford, J D; Crawford, John David; Jayaraman, Anandhan

    1997-01-01

    The amplitude equation for an unstable electrostatic wave is analyzed using an expansion in the mode amplitude $A(t)$. In the limit of weak instability, i.e. $\\gamma\\to 0^+$ where $\\gamma$ is the linear growth rate, the nonlinear coefficients are singular and their singularities predict the dependence of $A(t)$ on $\\gamma$. Generically the scaling $|A(t)|=\\gamma^{5/2}r(\\gamma t)$ as orders. This result predicts the electric field scaling $|E_k|\\sim\\gamma^{5/2}$ will hold universally for these instabilities (including beam-plasma and two-stream configurations) throughout the dynamical evolution and in the time-asymptotic state. In exceptional cases, such as infinitely massive ions, the coefficients are less singular and the more familiar trapping scaling $|E_k|\\sim\\gamma^2$ is recovered.

  4. Differential equations, associators, and recurrences for amplitudes

    Directory of Open Access Journals (Sweden)

    Georg Puhlfürst

    2016-01-01

    Full Text Available We provide new methods to straightforwardly obtain compact and analytic expressions for ϵ-expansions of functions appearing in both field and string theory amplitudes. An algebraic method is presented to explicitly solve for recurrence relations connecting different ϵ-orders of a power series solution in ϵ of a differential equation. This strategy generalizes the usual iteration by Picard's method. Our tools are demonstrated for generalized hypergeometric functions. Furthermore, we match the ϵ-expansion of specific generalized hypergeometric functions with the underlying Drinfeld associator with proper Lie algebra and monodromy representations. We also apply our tools for computing ϵ-expansions for solutions to generic first-order Fuchsian equations (Schlesinger system. Finally, we set up our methods to systematically get compact and explicit α′-expansions of tree-level superstring amplitudes to any order in α′.

  5. Differential equations, associators, and recurrences for amplitudes

    Science.gov (United States)

    Puhlfürst, Georg; Stieberger, Stephan

    2016-01-01

    We provide new methods to straightforwardly obtain compact and analytic expressions for ɛ-expansions of functions appearing in both field and string theory amplitudes. An algebraic method is presented to explicitly solve for recurrence relations connecting different ɛ-orders of a power series solution in ɛ of a differential equation. This strategy generalizes the usual iteration by Picard's method. Our tools are demonstrated for generalized hypergeometric functions. Furthermore, we match the ɛ-expansion of specific generalized hypergeometric functions with the underlying Drinfeld associator with proper Lie algebra and monodromy representations. We also apply our tools for computing ɛ-expansions for solutions to generic first-order Fuchsian equations (Schlesinger system). Finally, we set up our methods to systematically get compact and explicit α‧-expansions of tree-level superstring amplitudes to any order in α‧.

  6. New structures in scattering amplitudes: a review

    CERN Document Server

    Benincasa, Paolo

    2013-01-01

    We review some recent developments in the understanding of field theories in the perturbative regime. In particular, we discuss the notions of analyticity, unitarity and locality, and therefore the singularity structure of scattering amplitudes in general interacting theories. We describe their tree-level structure and their on-shell representations, as well as the links between the tree-level structure itself and the structure of the loop amplitudes. Finally, we describe the on-shell diagrammatics recently proposed both on general grounds and in the remarkable example of planar supersymmetric theories. This review is partially based on lectures given at: Dipartimento di Fisica and INFN, Universit\\`a di Bologna; Departamento de F{\\i}sica de Part{\\i}culas, Universidade de Santiago de Compostela; and as part of the program Strings@ar Lectures on Advanced Topics of High Energy Physics held at the IAFE

  7. Differential Equations, Associators, and Recurrences for Amplitudes

    CERN Document Server

    Puhlfuerst, Georg

    2015-01-01

    We provide new methods to straightforwardly obtain compact and analytic expressions for epsilon-expansions of functions appearing in both field and string theory amplitudes. An algebraic method is presented to explicitly solve for recurrence relations connecting different epsilon-orders of a power series solution in epsilon of a differential equation. This strategy generalizes the usual iteration by Picard's method. Our tools are demonstrated for generalized hypergeometric functions. Furthermore, we match the epsilon-expansion of specific generalized hypergeometric functions with the underlying Drinfeld associator with proper Lie algebra and monodromy representations. We also setup up our tools for computing epsilon-expansions for solutions to generic first-order Fuchsian equations (Schlesinger system). Finally, we apply our methods to systematically get compact and explicit alpha'-expansions of tree-level superstring amplitudes to any order in alpha'.

  8. Optical twists in phase and amplitude

    DEFF Research Database (Denmark)

    Daria, Vincent R.; Palima, Darwin; Glückstad, Jesper

    2011-01-01

    beams, the far field projection of the twisted optical beam maintains a high photon concentration even at higher values of topological charge. Optical twisters have therefore profound applications to fundamental studies of light and atoms such as in quantum entanglement of the OAM, toroidal traps......Light beams with helical phase profile correspond to photons having orbital angular momentum (OAM). A Laguerre-Gaussian (LG) beam is an example where its helical phase sets a phase-singularity at the optical axis and forms a ring-shaped transverse amplitude profile. Here, we describe a unique beam...... where both phase and amplitude express a helical profile as the beam propagates in free space. Such a beam can be accurately referred to as an optical twister. We characterize optical twisters and demonstrate their capacity to induce spiral motion on particles trapped along the twisters’ path. Unlike LG...

  9. Multilayered models for electromagnetic reflection amplitudes

    Science.gov (United States)

    Linlor, W. I.

    1976-01-01

    The remote sensing of snowpack characteristics with surface installations or with an airborne system could have important applications in water resource management and flood prediction. To derive some insight into such applications, the electromagnetic response of multilayer snow models is analyzed. Normally incident plane waves are assumed at frequencies ranging from 10 to the 6th power to 10 to the 10th power Hz, and amplitude reflection coefficients are calculated for models having various snow-layer combinations, including ice sheets. Layers are defined by a thickness, permittivity, and conductivity; the electrical parameters are constant or prescribed functions of frequency. To illustrate the effect of various layering combinations, results are given in the form of curves of amplitude reflection coefficients, versus frequency for a variety of models. Under simplifying assumptions, the snow thickness and effective dielectric constant can be estimated from the reflection coefficient variations as a function of frequency.

  10. Integrable spin chains and scattering amplitudes

    Energy Technology Data Exchange (ETDEWEB)

    Bartels, J.; Prygarin, A. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Lipatov, L.N. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Petersburg Nuclear Physics Institute (Russian Federation); Sankt-Peterburgskij Univ., St. Petersburg (Russian Federation)

    2011-04-15

    In this review we show that the multi-particle scattering amplitudes in N=4 SYM at large N{sub c} and in the multi-Regge kinematics for some physical regions have the high energy behavior appearing from the contribution of the Mandelstam cuts in the complex angular momentum plane of the corresponding t-channel partial waves. These Mandelstam cuts or Regge cuts are resulting from gluon composite states in the adjoint representation of the gauge group SU(N{sub c}). In the leading logarithmic approximation (LLA) their contribution to the six point amplitude is in full agreement with the known two-loop result. The Hamiltonian for the Mandelstam states constructed from n gluons in LLA coincides with the local Hamiltonian of an integrable open spin chain. We construct the corresponding wave functions using the integrals of motion and the Baxter-Sklyanin approach. (orig.)

  11. On Triple-Cut of Scattering Amplitudes

    CERN Document Server

    Mastrolia, Pierpaolo

    2007-01-01

    It is analysed the triple-cut of one-loop amplitudes in dimensional regularisation within spinor-helicity representation. The triple-cut is defined as a difference of two double-cuts with the same particle content, and a same propagator carrying, respectively, causal and anti-causal prescription in each of the two cuts. That turns out into an effective tool for extracting the coefficients of the three-point functions (and higher-point ones) from one-loop-amplitudes. The phase-space integration is oversimplified by using residues theorem to perform the integration over the spinor variables, via the holomorphic anomaly, and a trivial integration on the Feynman parameter. The results are valid for arbitrary values of dimensions.

  12. Subleading Soft Factor for String Disk Amplitudes

    CERN Document Server

    Schwab, Burkhard U W

    2014-01-01

    We investigate the behavior of superstring disk scattering amplitudes in the presence of a soft external momentum at finite string tension. We prove that there are no $\\alpha'$-corrections to the field theory form of the subleading soft factor $S^{(1)}$. At the end of this work, we also comment on the possibility to find the corresponding subleading soft factors in closed string theory using our result and the KLT relations.

  13. Organizing Filament of Small Amplitude Scroll Waves

    Institute of Scientific and Technical Information of China (English)

    ZHOU TianShou; ZHANG SuoChun

    2001-01-01

    We theoretically analyze the organizing filament of small amplitude scroll waves in general excitable media by perturbation method and explicitly give the expressions of coefficients in Keener theory. In particular for the excitable media with equal diffusion, we obtain a close system for the motion of the filament. With an example of the Oregonator model, our results are in good agreement with those simulated by Winfree.``

  14. Ward identities for amplitudes with reggeized gluons

    Energy Technology Data Exchange (ETDEWEB)

    Bartles, J. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; Universidad Tecnica Federico Santa Maria, Valparaiso (Chile). Dept. de Fisica; Lipatov, L.N. [Hamburg Univ. (Germany). 2. Inst. fuer Theoretische Physik; St. Petersburg Nuclear Physics Institute (Russian Federation); Vacca, G.P. [INFN, Sezione di Bologna (Italy)

    2012-05-15

    Starting from the effective action of high energy QCD we derive Ward identities for Green's functions of reggeized gluons. They follow from the gauge invariance of the effective action, and allow to derive new representations of amplitudes containing physical particles as well as reggeized gluons. We explicitly demonstrate their validity for the BFKL kernel, and we present a new derivation of the kernel.

  15. Automation of 2-loop Amplitude Calculations

    CERN Document Server

    Jones, S P

    2016-01-01

    Some of the tools and techniques that have recently been used to compute Higgs boson pair production at NLO in QCD are discussed. The calculation relies on the use of integral reduction, to reduce the number of integrals which must be computed, and expressing the amplitude in terms of a quasi-finite basis, which simplifies their numeric evaluation. Emphasis is placed on sector decomposition and Quasi-Monte Carlo (QMC) integration which are used to numerically compute the master integrals.

  16. Automatic generation of tree level helicity amplitudes

    CERN Document Server

    Stelzer, T

    1994-01-01

    The program MadGraph is presented which automatically generates postscript Feynman diagrams and Fortran code to calculate arbitrary tree level helicity amplitudes by calling HELAS[1] subroutines. The program is written in Fortran and is available in Unix and VMS versions. MadGraph currently includes standard model interactions of QCD and QFD, but is easily modified to include additional models such as supersymmetry.

  17. Nucleon and $N^* (1535)$ Distribution Amplitudes

    CERN Document Server

    Braun, V M; Göckeler, M; Hagen, C; Horsley, R; Nakamura, Y; Pleiter, D; Rakow, P E L; Schäfer, A; Schiel, R W; Schierholz, G; Stüben, H; Zanotti, J M

    2010-01-01

    The QCDSF collaboration has investigated the distribution amplitudes and wavefunction normalization constants of the nucleon and its parity partner, the $N^* (1535)$. We report on recent progress in the calculation of these quantities on configurations with two dynamical flavors of $\\mathcal{O}(a)$-improved Wilson fermions. New data at pion masses of approximately 270 MeV helps in significantly reducing errors in the extrapolation to the physical point.

  18. Scattering Amplitudes via Algebraic Geometry Methods

    DEFF Research Database (Denmark)

    Søgaard, Mads

    unitarity cuts. We take advantage of principles from algebraic geometry in order to extend the notion of maximal cuts to a large class of two- and three-loop integrals. This allows us to derive unique and surprisingly compact formulae for the coefficients of the basis integrals. Our results are expressed...... in terms of certain linear combinations of multivariate residues and elliptic integrals computed from products of tree-level amplitudes. Several explicit examples are provided...

  19. Connecting physical resonant amplitudes and lattice QCD

    CERN Document Server

    Bolton, Daniel R; Wilson, David J

    2015-01-01

    We present a determination of the isovector, $P$-wave $\\pi\\pi$ scattering phase shift obtained by extrapolating recent lattice QCD results from the Hadron Spectrum Collaboration using $m_\\pi =236$ MeV. The finite volume spectra are described using extensions of L\\"uscher's method to determine the infinite volume Unitarized Chiral Perturbation Theory scattering amplitude. We exploit the pion mass dependence of this effective theory to obtain the scattering amplitude at $m_\\pi= 140$ MeV. The scattering phase shift is found to be in good agreement with experiment up to center of mass energies of 1.2 GeV. The analytic continuation of the scattering amplitude to the complex plane yields a $\\rho$-resonance pole at $E_\\rho= \\left[755(2)(1)(^{20}_{02})-\\frac{i}{2}\\,129(3)(1)(^{7}_{1})\\right]~{\\rm MeV}$. The techniques presented illustrate a possible pathway towards connecting lattice QCD observables of few-body, strongly interacting systems to experimentally accessible quantities.

  20. Reconstructed animation from four-phase grip MRI of the wrist with ulnar-sided pain.

    Science.gov (United States)

    Oda, T; Wada, T; Iba, K; Aoki, M; Tamakawa, M; Yamashita, T

    2013-09-01

    In order to visualize dynamic variations related to ulnar-sided wrist pain, animation was reconstructed from T2* coronal-sectioned magnetic resonance imaging in each of the four phases of grip motion for nine wrists in patients with ulnar pain. Eight of the nine wrists showed a positive ulnar variance of less than 2 mm. Ulnocarpal impaction and triangular fibrocartilage complex injury were assessed on the basis of animation and arthroscopy, respectively. Animation revealed ulnocarpal impaction in four wrists. In one of the four wrists, the torn portion of the articular disc was impinged between the ulnar head and ulnar proximal side of the lunate. In another wrist, the ulnar head impacted the lunate directly through the defect in the articular disc that had previously been excised. An ulnar shortening osteotomy successfully relieved ulnar wrist pain in all four cases with both ulnocarpal impaction and Palmer's Class II triangular fibrocartilage complex tears. This method demonstrated impairment of the articular disc and longitudinal instability of the distal radioulnar joint simultaneously and should be of value in investigating dynamic pathophysiology causing ulnar wrist pain.