WorldWideScience

Sample records for gray gy cobalt-60

  1. Key technology studies of GY-20 and GY-40 High-capacity cobalt-60 transport casks

    International Nuclear Information System (INIS)

    Liu Huifang; Zhang Xin

    2012-01-01

    GY-20 and GY-40 high-capacity cobalt-60 transport casks are used to transport cobalt-60 industrial irradiators and cobalt-60 bundles. The radioactive contents have special features of high-activity and high residual heat, so only a few countries such as Canada, England and Russia have design capacity. The key technologies and corresponding solutions were studied for the design and manufacture of the cask taking into account the structural, thermal, mechanics and shield requests. A series of tests prove that the cask structure design, design criteria for lead coating structure and quality control measurements are reasonable and effective, and the cask shield integrity can be ensured for all conditions. The casks have ability to transport high-activity sealed sources safely, and the design of cask satisfies the requirement of design code and standard. It can provide reference for other B type package. (authors)

  2. The cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Jigang, A.; Liye, Z.; Yisi, L.; Haifeng, W.; Zhifang, W.; Liqiang, W.; Yuanshi, Z.; Xincheng, X.; Furong, L.; Baozeng, G.; Chunfa, S.

    1997-01-01

    The Institute of Nuclear Energy Technology (INET) has successfully designed and constructed a container (cargo) scanner, which uses cobalt-60 of 100-300 Ci as radiation source. The following performances of the Cobalt-60 container scanner have been achieved at INET: a) IQI (Image Quality Indicator) - 2.5% behind 100 mm of steel; b) CI (Contrast Indicator) - 0.7% behind 100 mm of steel; c) SP (Steel Penetration) - 240 mm of steel; d) Maximum Dose per Scanning - 0.02mGy; e) Throughput - twenty 40-foot containers per hour. These performances are equal or similar to those of the accelerator scanners. Besides these nice enough inspection properties, the Cobalt-60 scanner possesses many other special features which are better than accelerator scanners: a) cheap price - it will be only or two tenths of the accelerator scanner's; b) low radiation intensity - the radiation protection problem is much easier to solve and a lot of money can be saved on the radiation shielding building; c) much smaller area for installation and operation; d) simple operation and convenient maintenance; e) high reliability and stability. The Cobalt-60 container (or cargo) scanner is satisfied for boundary customs, seaports, airports and railway stations etc. Because of the nice special features said above, it is more suitable to be applied widely. Its high properties and low price will make it have much better application prospects

  3. Cobalt 60 commercial irradiation facilities

    International Nuclear Information System (INIS)

    West, G.

    1985-01-01

    The advantage of using cobalt 60 for ionizing treatment is that it has excellent penetration. Gamma plants are also very efficient, in as much as there is very little mechanical or electrical equipment in a gamma irradiation facility. The average efficiency of a gamma plant is usually around 95% of all available processing time

  4. Cobalt60 plaques in recurrent retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R. (Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, NY, NY (USA))

    1991-08-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 {times} 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications.

  5. Cobalt60 plaques in recurrent retinoblastoma

    International Nuclear Information System (INIS)

    Fass, D.; McCormick, B.; Abramson, D.; Ellsworth, R.

    1991-01-01

    Cobalt60 plaque irradiation is one treatment option for patients with recurrent retinoblastoma following conventional external beam irradiation (ERT). Tumorocidal doses can be delivered without excessive risk of normal tissue injury. In patients not considered candidates for xenon arc or cryotherapy, 60Co is an alternative to enucleation. Between 1968 and 1987, 85 patients were treated with 60Co plaques, 72 of whom had failed prior ERT. Age at diagnosis ranged from 1 week to 4 years. There are 37 males and 35 females. Seventy-one patients had bilateral disease and one had unilateral. Three patients had both eyes plaqued. Prior ERT ranged from 30 to 70 Gy (mean 4200 Gy). Time from initial therapy to failure ranged from 13 to 60 months. Cobalt plaques of 10 mm, 15 mm, or 10 x 15 mm were used depending on tumor size and location. Dose prescribed to the apex of the tumor ranged from 30 to 50 Gy (median 40 Gy) given over 3 to 8 days. Twelve patients had two plaque applications; three patients had three plaque applications. All patients were followed with routine ophthalmoscopic examinations. Follow-up ranged from 2 to 22 years (mean 8.7). Seven patients died of metastatic disease; 10 patients developed non-ocular second tumors. Thirty patients required enucleation. Twenty-two patients had clear tumor progression, two patients had radiation complications, and six patients had a combination of tumor growth and complications. Cobalt60 can salvage eyes in retinoblastoma patients failing ERT. Currently, the authors are using I125 in an attempt to spare normal ocular tissue and reduce subsequent complications

  6. Cobalt-60 gamma irradiation of shrimp

    International Nuclear Information System (INIS)

    Sullivan, N.L.B.

    1993-01-01

    Meta- and ortho-tyrosine were measured using high performance liquid chromatography (HPLC) in conjunction with electrochemical detection in shrimp irradiated using cobalt-60 gamma radiation in the absorbed dose range 0.8 to 6.0 kGy, in nonirradiated shrimp, and in bovine serum albumin (BSA) irradiated in dilute aqueous solution at 25.0 kGy. Ortho-tyrosine was measured in nonirradiated BSA. Para-, meta-, and ortho-tyrosine was measured using HPLC in conjunction with uv-absorption detection in dilute aqueous solutions of phenylalanine irradiated in the absorbed dose range 16.0 to 195.0 kGy. The measured yields of tyrosine isomers were approximately linear as a function of absorbed dose in shrimp, and in irradiated solutions of phenylalanine up to 37.0 kGy. The occurrence of meta- and ortho-tyrosine, which had formerly been considered unique radiolytic products, has not previously been reported in nonirradiated shrimp or BSA. The conventional hydrolyzation and analytical techniques used in the present study to measure meta- and ortho-tyrosine may provide the basis for a method to detect and determine the dose used in food irradiation

  7. Cobalt 60 availability for radiation processing

    International Nuclear Information System (INIS)

    Fraser, F.M.

    1986-01-01

    In the last 20 years, the steady and significant growth in the application of radiation processing to industrial sterilization has been seen. The principal application of this technology is the sterilization of disposable medical products, food irradiation, the irradiation of personal care goods and so on. At present, more than 70 million curies of cobalt-60 supplied by Atomic Energy of Canada Ltd. have been used for gamma processing in these applications. This is estimated to be more than 80 % of the total cobalt-60 in service in the world. Commercial food irradiation has an exciting future, and as to the impact of food irradiation on the availability of cobalt-60 over the next ten years, two principal factors must be examined, namely, the anticipated demand for cobalt-60 in all radiation processing applications, and the supply of cobalt-60 to reliably meet the expected demand. As for the cobalt-60 in service today, 90 % is used for the sterilization of disposable medical products, 5 % for food irradiation, and 5 % for other application. The demand for up to 30 million curies of cobalt-60 is expected over the next 10 years. Today, it is estimated that over 150,000 tons of spices, fruit and fish are irradiated. The potential cobalt-60 production could exceed 110 million curies per year. Gamma processing application will demand nearly 50 million curies in 1990. (Kako, I.)

  8. Transport of cobalt-60 industrial radiation sources

    Science.gov (United States)

    Kunstadt, Peter; Gibson, Wayne

    This paper will deal with safety aspects of the handling of Cobalt-60, the most widely used industrial radio-isotope. Cobalt-60 is a man-made radioisotope of Cobalt-59, a naturally occurring non radioactive element, that is made to order for radiation therapy and a wide range of industrial processing applications including sterilization of medical disposables, food irradiation, etc.

  9. Ultrasonography-guided cobalt-60 brachytherapy for malignant glioma

    International Nuclear Information System (INIS)

    Sakai, Noboru; Takenaka, Katsunobu; Ueda, Tatsuya

    1989-01-01

    Brachytherapy with cobalt-60 source is reported. In this method it is characterized that the source is inserted interstitially with remote control system by after-loading method via outer catheter (using tandem tube), which was established in the center of residual tumor, using ultrasonography guide with trepanation, or intraoperatively put within the dead space after tumor resection. Six cases of deep-seated and recurrent malignant glioma, were treated with this method. A total dose of 20 to 45 Gy (10 to 15 Gy/day for 2 to 3 days) was delivered to the target. Additionally conventional external irradiation was followed. The effect of cobalt-60 brachytherapy on such tumors were favorable especially for well-circumscribed glioma less than 3 cm on CT scan. (author)

  10. An elevator for cobalt-60 source

    International Nuclear Information System (INIS)

    Tang Zaimin; Liang Donghu

    1990-07-01

    The elevator used for cobalt-60 source is a key device in the irradiation industry. It plays an important role in the safety and control of irradiation operation as well as the utilization rate of radiation source. From 1983 to 1986, Beijing Institute of Nuclear Engineering undertook designing of various size irradiation projects for different uses. Since then a kind of cobalt-60 source elevator suited for the irradiator of wet-source-storage has been chosen. It is reliable in the operation and complete in the function. An automatic control circuit brings the systems of cobalt-60 source elevator into an interlock system which ensures the irradiation operation safety. Besides introducing the structural features and performance of this elevator, the conditions of safety interlocking in raising or lowering the cobalt-60 source is also discussed. The discussion is from the safety viewpoint of operating an irradiator and irradiation technology

  11. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Malkoske, G.R.; Norton, J.L.; Slack, J.

    2002-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments, but are primarily used to sterilize single-use medical products including; surgical kits, gloves, gowns, drapes, and cotton swabs. Other applications include sanitization of cosmetics, microbial reduction of pharmaceutical raw materials, and food irradiation. The technology for producing the cobalt-60 isotope was developed by MDS Nordion and Atomic Energy of Canada Limited (AECL) almost 55 years ago using research reactors at the AECL Chalk River Laboratories in Ontario, Canada. The first cobalt-60 source produced for medical applications was manufactured by MDS Nordion and used in cancer therapy. The benefits of cobalt-60 as applied to medical product manufacturing, were quickly realized and the demand for this radioisotope quickly grew. The same technology for producing cobalt-60 in research reactors was then designed and packaged such that it could be conveniently transferred to a utility/power reactor. In the early 1970's, in co-operation with Ontario Power Generation (formerly Ontario Hydro), bulk cobalt-60 production for industrial irradiation applications was initiated in the four Pickering A CANDU reactors. As the demand and acceptance of sterilization of medical products grew, MDS Nordion expanded its bulk supply by installing the proprietary Canadian technology for producing cobalt-60 in additional CANDU reactors. CANDU is unique among the power reactors of the world, being heavy water moderated and fuelled with natural uranium. They are also designed and supplied with stainless steel adjusters, the primary function of which is to shape the neutron flux to optimize reactor power and fuel bum-up, and to provide excess reactivity needed to overcome xenon-135 poisoning following a reduction of power. The reactor is designed to develop full power output with all of the adjuster

  12. Cobalt-60 production in CANDU reactors

    International Nuclear Information System (INIS)

    Ross, Michel; Lemire, Christian

    2002-01-01

    CANDU reactors can produce cobalt-60 very efficiently and with an interesting return on investment. This paper discusses what is needed to convert a CANDU reactor into a cobalt-60 producer: what are the different phases, the safety studies required, the physical modifications needed, and what is the minimum involvement of the utility owning the plant. The past ten years of experience of Hydro-Quebec as a cobalt-60 producer will be reviewed, including the management of the risk of both incident and electricity generation loss, and including the benefits for the utility and its personnel. Originally a simple metal used for centuries as a pigment, cobalt-59 today is transformed into cobalt-60, a radioactive element of unprecedented value. Well known in medicine for cancer treatment, cobalt-60 is also used to sterilize a wide range of disposable medical products used in hospitals and to sanitize pharmaceutical and cosmetic products. Cobalt-60 is proving to be a new and effective solution, in the food sector, for preserving harvests and controlling food-borne diseases, or to advantageously replace certain gases and chemical products which are suspected of being harmful or carcinogenic. There are also other applications, such as: hardening of some plastics, treatment of sewage sludge and elimination of harmful insect populations. With a half-life of 5,3 years, cobalt-60 is a metal not found in nature. It is a radioactive isotope produced by exposing stable nuclei of cobalt-59 to neutrons. One of the best places to find such an important neutron source is a nuclear reactor. High energy gamma rays are then emitted during the process of radioactive decay, where cobalt-60 seeks again its stable state

  13. Cobalt-60 production in CANDU power reactors

    International Nuclear Information System (INIS)

    Slack, J.; Norton, J.L.; Malkoske, G.R.

    2003-01-01

    MDS Nordion has been supplying cobalt-60 sources to industry for industrial and medical purposes since 1946. These cobalt-60 sources are used in many market and product segments. The major application is in the health care industry where irradiators are used to sterilize single use medical products. These irradiators are designed and built by MDS Nordion and are used by manufacturers of surgical kits, gloves, gowns, drapes and other medical products. The irradiator is a large shielded room with a storage pool for the cobalt-60 sources. The medical products are circulated through the shielded room and exposed to the cobalt-60 sources. This treatment sterilizes the medical products which can then be shipped to hospitals for immediate use. Other applications for this irradiation technology include sanitisation of cosmetics, microbial reduction of pharmaceutical raw materials and food irradiation. The cobalt-60 sources are manufactured by MDS Nordion in their Cobalt Operations Facility in Kanata. More than 75,000 cobalt-60 sources for use in irradiators have been manufactured by MDS Nordion. The cobalt-60 sources are double encapsulated in stainless steel capsules, seal welded and helium leak tested. Each source may contain up to 14,000 curies. These sources are shipped to over 170 industrial irradiators around the world. This paper will focus on the MDS Nordion proprietary technology used to produce the cobalt-60 isotope in CANDU reactors. Almost 55 years ago MDS Nordion and Atomic Energy of Canada developed the process for manufacturing cobalt-60 at the Chalk River Labs, in Ontario, Canada. A cobalt-59 target was introduced into a research reactor where the cobalt-59 atom absorbed one neutron to become cobalt-60. Once the cobalt-60 material was removed from the research reactor it was encapsulated in stainless steel and seal welded using a Tungsten Inert Gas weld. The first cobalt-60 sources manufactured using material from the Chalk River Labs were used in cancer

  14. Total quality management of cobalt-60 sources

    International Nuclear Information System (INIS)

    Malkoske, G.R.

    1999-01-01

    Total Quality Management of Cobalt-60 sources by a supplier requires a life cycle approach to source management. This covers various aspects, including design, manufacturing, installation, field inspection, source surveillance and return of cobalt-60 sources at the end of their useful life. The Total Quality Management approach demonstrates a strong industry commitment to the beneficial use of gamma technology for industrial irradiation applications in both developed nations and in those nations who are developing their infrastructure and techniques for the beneficial use of this technology. MDS Nordion continues to demonstrate its support and commitment to the industry by developing and implementing state-of-the-art standards for the safe use of cobalt-60 sources

  15. Cobalt-60 gamma radiation effects on degradation of pesticides used in stored rice and beans

    International Nuclear Information System (INIS)

    Groppo, Gerson A.

    1988-02-01

    The present work, carried out at CENA, an agriculture nuclear energy center - University of Sao Paulo - Brazil, investigates the Cobalt-60 gamma radiation effects on insecticides applied to stored rice and beans. The radiation dose applied - 200 Gy - to the stored rice and beans treated with insecticides was not sufficient to cause a noticeable chemical degradation through insect mortality. (author). 31 refs., 23 tabs

  16. Cobalt-60 control in Ontario Hydro reactors

    International Nuclear Information System (INIS)

    Lacy, C.S.

    1988-01-01

    This paper discusses the impact of specifying reduced Cobalt-59 in the primary heat transport circuit materials of construction on the radiation fields developed around the primary circuit. An eight-fold reduction in steam generator radiation fields due to Cobalt-60 has been observed for two identical sets of reactors, one with and one without Cobalt-59 control. The comparison is between eight reactors at the Pickering Nuclear Generating Station (PNGS). Units 5 to 8 (PNGS-B) are identical to Units 1 to 4 (PNGS-A) except that PNGS-B has reduced impurity Cobalt-59 in the alloys of construction and a reduced use of stellite. The effects of chemistry control are also discussed

  17. Effects of bathing on skin exposed to Cobalt-60 teletherapy

    International Nuclear Information System (INIS)

    Bohannan, P.A.

    1982-01-01

    The problem of this study was to determine the effects of bathing or not bathing on the degree of skin reaction occurring in patients receiving Cobalt-60 radiation therapy to the chest, back, or head and neck. A quasi experimental study was done using a 2 x 7 repeated measures design. Sixty-seven subjects receiving Cobalt-60 radiation therapy at the Moncrief Radiation Center in Fort Worth, Texas, were randomly assigned to an experimental group who did not bathe during therapy and a control group who did bathe with water during therapy. Observations were made after each 1000 rads of therapy and two weeks after the final treatment. Erythema and pigmentation measurements were taken using the Photovolt 670 and rates were assigned using the Baker-Leith Rating Scale. Findings from the study suggest that bathing the portal of entry with water during the treatment period does not influence the degree of skin response that occurs from Cobalt-60 teletherapy

  18. C-188 cobalt-60 sealed source integrity: source monitoring

    International Nuclear Information System (INIS)

    Defalco, G.M.; Shah, V.

    1995-01-01

    The integrity of C-188 cobalt-60 sealed sources used for radiation processing will be a key factor in the continued industrial acceptance and growth of gamma irradiation technology. Given the public's relatively poor understanding of most nuclear topics and the news media's tendency to sensationalize events, it is appropriate for suppliers and users of gamma technology to be vigilant and conservative regarding the application of cobalt-60 sources to industrial purposes. Nordion's recent decision to extend the optional warranty on its C-188 cobalt-60 sealed source from 15 years to 20 years is based on over 30 years of data generated from its on-going SOURCE SURVEILLANCE PROGRAM. This paper presents an overview of the C-188 SOURCE SURVEILLANCE PROGRAM. (author)

  19. Cobalt 60 gamma irradiation current status, trends and insights

    International Nuclear Information System (INIS)

    Corley, John T.

    1998-01-01

    This paper discusses the current status, trends and insights into the continued, safe use of cobalt 60 gamma irradiation. Also presented are some of the many initiatives undertaken at MDS Nordion. Topics covered include our investment for the future supply of raw materials and the latest news from source production. Briefly presented are the tasks associated with the safe transport of cobalt 60 around the world. Discussed is cobalt 60 usage at the customer site; more specifically maintaining source integrity, source utilization and irradiator design trends. Highlighted are industry trends for North America, Europe and the rest of the world. Finally presented are the challenges and opportunities for the industry. Stressed in the paper is the need to work together

  20. Activation of cobalt 60 in the LVR-15 reactor core

    International Nuclear Information System (INIS)

    Melichar, F.

    1995-12-01

    Cobalt disks were irradiated in the LVR-15 reactor and the relevant cobalt-60 production parameters, particularly the formation rate, were measured. The data were compared with those from previous work by other authors and some discrepancies were found. It is concluded that additional experiments have to be performed in order to obtain reliable data, usable in economic balance assessment with respect to the use of hot chambers for the production of sealed cobalt-60 sources. (P.A.). 4 tabs., 3 refs., 10 annexes

  1. Investigation of the production of cobalt-60 via particle accelerator

    Directory of Open Access Journals (Sweden)

    Artun Ozan

    2017-01-01

    Full Text Available The production process of cobalt-60 was simulated by a particle accelerator in the energy range of 5 to 100 MeV, particle beam current of 1 mA, and irradiation time of 1 hour to perform yield, activity of reaction, and integral yield for charged particle-induced reactions. Based on nuclear reaction processes, the obtained results in the production process of cobalt-60 were also discussed in detail to determine appropriate target material, optimum energy ranges, and suitable reactions.

  2. Effects of cobalt-60 low doses radiation on beam, rice and radish seeds

    International Nuclear Information System (INIS)

    Kikuchi, O.K.

    1987-01-01

    The effects of cobalt-60 gamma radiation on seeds of bean (Phaseolus vulgaris L.), rice (Oryza sativa L.) and radish (Raphanus sativus L.) were studied. Bean and rice seeds were irradiated with 3.5 and 7.7 Gy (32 Gy/h). There was an apparent acceleration on rice seed germination with 3.5 Gy when they were stored for 6 days after irradiation, but the same dose caused a delay when the store time was 1 day. Bean seeds germination was not modified by 3.5 and 7.7 Gy, but the fresh and dry weight of young plants showed an increase, mainly due the major quantity of water in the embryonic axis. Bean seeds were irradiated with 0.5 and 2.0 Gy (30 Gy/h). Seeds germination showed a slight delay irradiating with 0.5 Gy, while height, fresh and dry weight and primary leaves area of the young plants as well as number of nodes, leaves, flowers, beans and seeds were not modified after irradiation with 0.5 and 2.0 Gy. Radish seeds irradiated with 10 and 30 Gy at dose rates of 4.5, 22.5 and 45.0 Gy/h showed a germination delay and fresh and dry weight values for young plants leaves lower than control. Roots of totally developed plants showed no modifications in weight, volume, mean diameter, lenght and in the amount of soluble reducing sugar. (author)

  3. Disinfection of the bee hive's American Foulbrood by gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Gosselin, P.; Charbonneau, R.

    1990-01-01

    Gamma radiation from Cobalt-60 was used to sterilize honeybee combs contaminated by Bacillus larvae. The determination of the radiosensitivity (D 10 ) was done on cultured cells in Brain Heart Infusion broth and was found to be determined at 125 Gy. The D 10 of isolated spores from contaminated combs was then determined at 0,518 kGy and the D 10 of spores irradiated in their own original environment was found at 2,05 kGy. These treated combs were then sent back in the beehives. The bees cleaned the combs thoroughly and started the storage of honey in some cells. Eggs were also layed in others. Forty five days later, there were still no sing of re-appearance of the American Foulbrood disease. (author)

  4. Comparison of three methods for the calibration of cobalt-60 teletherapy machine

    International Nuclear Information System (INIS)

    Adewole, O.O.; Akinlade, B.I.; Oyekunle, O.E.; Ejeh, J.

    2011-01-01

    Two methods of indirect determination of dose rate (machine output) from the Cobalt-60 Teletherapy machines has been reviewed and compared with conventional measurement with dosimetry devices. The dose rate were determined by: (i) Conventional measurement (ii) Application of the law of radioactive decay and (iii) Assumption of 1 % radioactive decomposition per month. The dose rate at the depth of maximum dose (Z m ax), collimator size of 10cm x 10cm and Source to Skin Distance (SSD) of 80cm obtained from these methods were 203.7200cGy/min, 203.8090cGy/min and 203.9530cGy/min respectively. The ratio of dose rate obtained from measurement to that from calculations is within the tolerance value of 2%.

  5. New avenues in cobalt-60 production at Ontario Hydro

    International Nuclear Information System (INIS)

    Mylvaganam, C.K.; Ronchka, R.A.

    1990-01-01

    Ontario Hydro produces cobalt-60 in the control rods of twelve power reactors. These reactors have a typical flux of 2 x 10 14 neutrons/cm 2 /s, making them efficient producers of cobalt-60. Current annual production is 45 million curies. Since the primary function of these reactors is the production of electricity, their flexibility to meet the needs of commercial cobalt production by the control rod route is limited. Ontario Hydro is therefore developing innovative production techniques, making use of the CANDU reactor's unique ability to be fuelled on-power. These techniques will enable production to better respond to the market's requirements for quantity and specific activity. As it is supplementary to control rod production, annual supply could potentially reach 165 million curies. (author)

  6. Consumer products polluted by cobalt-60 on the Dutch market

    International Nuclear Information System (INIS)

    Bothof, J.

    2002-01-01

    In several previous articles of this magazine attention has been paid to reporting of radioactive materials in scrap metals and incidents with radioactive materials, which were dealt with by the VROM-Inspectie Regio Zuid-West (Inspection for the Region South-West in the Netherlands). In this article attention is paid to a special incident with new stainless steel flanges, polluted by cobalt 60 [nl

  7. Cobalt-60 in the treatment of cancer-future scenario

    International Nuclear Information System (INIS)

    Sastri, K.V.S.; Patil, B.N.; Kohli, A.K.

    2009-01-01

    Treatment of cancer using radiation is established method. Cobalt-60 is the workhorse of cancer treatment from the beginning. Later linear accelerators with more accessories were developed and are now used for the advanced treatments like IMRT, IGRT etc. Gammaknife, Gyroknife and supergamma machines using 60 Co have also taken roots for the treatment of cancer. The use of 60 Co in the treatment of cancer is expected to continue for some more time to come. (author)

  8. Nationwide survey of cobalt-60 teletherapy. Final report

    International Nuclear Information System (INIS)

    Thompson, D.L.; Kearly, F.E.; Wyckoff, H.O.; Gitlin, J.N.; Reffit, E.B.; Shangold, E.J.

    1980-08-01

    The Bureau of Radiological Health and the National Bureau of Standards conducted a nationwide survey of cobalt-60 teletherapy facilities to determine their accuracy in delivery of a prescribed dose to a phantom. Participation was obtained from 684 respondents or 75 percent of US facilities. For each cobalt-60 unit the average dose recorded on five dosimeters was within 5 percent of the prescribed value for 83 percent of the respondents and only exceeded a 10 percent difference for 3 percent of the respondents. Sufficient information for reconstruction of dose calculations was available for 87 percent of the participating facilities. Of these reconstructed calculations, 56 percent were within 1 percent of the prescribed dose of 300 rads. The analysis of data from the survey showed that better performance were related to a number of factors. Among these were expressing the machine calibration in terms of dose rate, performing the machine calibration on an annual basis, and correcting for source decay on a monthly basis. Larger facilities achieved better results than smaller facilities when calculating the absorbed dose rate. Also, each 4 machine characteristics (isocentric mounting, short exposure time, high normalized output, and long treatment distance) were related to better performance with regard to both dosimeter readings and calculated doses. Larger facilities were more likely to be using a cobalt-60 unit having those characteristics

  9. Quarantine treatment in eggs of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), with gamma radiation of Cobalt-60

    International Nuclear Information System (INIS)

    Silva, L.K.F.; Arthur, V.; Nava, D.E.; Parra, J.R.P.

    2006-01-01

    The objective of this work has been to determine the lethal dose of gamma radiation of Cobalt-60 for the Stenoma catenifer eggs. For the irradiation of the eggs an irradiador Gammacell-220 (CO60) was utilized, (Rate dose: 1.054 kGY/h). The doses were: 0, 25, 50, 75, 100, 125 and 150 Gy, 90 eggs/dose (six repetitions). The number of caterpillars emerged was evaluated, and the survivors growed in seeds of avocado. The adults obtained were coupled with normal insects, growed in boxes with double face paper containing the food (10% honey) and a fruit of avocado. The experimental design was totally random, being the data submitted to the analysis of the varianza and the averages compared by the test of Tukey (P=5%). The emergence of caterpillars from the treated eggs with dose of 0, 25 and 50 Gy was verified. The dose of 50 Gy caused deformation in the caterpillars emerged. The effect of the gamma radiation in the viability of the eggs was proportional to the dose increase. The adults from the eggs dealt with 25 Gy presented non viabilty of 92,85 and 100% for male and female, respectively. A radiation gamma of 75 Gy is recommended for treatment quarantine for avocado fruits infested with of S. catenifer eggs

  10. Absolute exposure determination of cobalt-60 gamma radiation

    International Nuclear Information System (INIS)

    Ahmad, S.S.; Ali, A.; Orfi, S.D.

    1986-02-01

    The report describes the procedure for the determination of absolute exposure for Cobalt-60 gamma radiation. A graphite cavity chamber, nominal volume of 1 cm 3 , manufactured by Austrian Research Centre Seibersdorf has been used. The exposure rate at reference distance determined with the graphite chamber was compared with mean exposure rate measured with NPL-Therapy level X-ray exposure meter normalized to same date. An agreement of 0.39% was found between the two measuring systems, which seems to be very encouraging and quite satisfactory. (authors)

  11. Economics of gamma processing in cobalt-60 irradiation facilities

    International Nuclear Information System (INIS)

    Gay, H. G.; Kotler, J. G.

    1985-01-01

    Gamma processing by cobalt-60 is well established. However, since irradiation of food is relatively new from the commercial point of view, it is important to assess costs of gamma irradiation in the context of food processing. Five different types of AECL-RCC irradiation equipment are examined in terms of their throughputs, and capital and operating costs. Using these figures, costs of irradiation of nine types of food products are presented. In general, these represent about 2-10% of the wholesale cost of these products

  12. Sensory analysis of dairy products irradiated with cobalt-60 at -78 degrees C

    International Nuclear Information System (INIS)

    Hashisaka, A.E.; Einstein, M.A.; Rasco, B.A.; Hungate, F.P.; Dong, F.M.

    1990-01-01

    Sensory evaluations by healthy individuals were conducted on cobalt-60 irradiated retail dairy products which were to be incorporated into the low microbial diets of immunosuppressed patients. Irradiation (40 kGy at -78 degrees C) caused little change in product color or texture, but generally there was a decrease in overall acceptability and an increase in off-flavor and aftertaste. Modified atmosphere packaging (nitrogen, helium, or air) or antioxidant addition (ascorbyl palmitate or a combination of butylated hydroxyanisole and butylated hydroxytoluene) prior to irradiation were effective in preserving specific sensory attributes, which in some cases resulted in improved overall acceptability (helium packed peppermint ice cream; ascorbyl palmitate treated strawberry yogurt bars) when compared to untreated irradiated products

  13. Differential gene expression in primary fibroblasts induced by proton and cobalt-60 beam irradiation

    DEFF Research Database (Denmark)

    Nielsen, Steffen; Bassler, Niels; Grzanka, Leszek

    2017-01-01

    profile: entrance, mid-SOBP and at the SOBP distal edge. Dose was delivered in three fractions × 3.5 Gy(RBE) (RBE 1.1). Cobalt-60 (Co-60) irradiation was used as reference. Real-time qPCR was performed to determine gene expression levels for 17 genes associated with inflammation response, fibrosis...... and angiogenesis. RESULTS: Differences in median gene expression levels were observed for multiple genes such as IL6, IL8 and CXCL12. Median IL6 expression was 30%, 24% and 47% lower in entrance, mid-SOBP and SOBP distal edge groups than in Co-60 irradiated cells. No genes were found to be oppositely regulated...... fibroblast cultures. Inflammatory factors were generally less extensively upregulated by proton irradiation compared with Co-60 photon irradiation. These effects may possibly influence the development of normal tissue damage in patients treated with proton beam therapy....

  14. Quarantine treatment for Sitophilus zeamais (Coleoptera: Curculionidae) through gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Ramos, Amanda Cristina Oliveira; Potenza, Marcos Roberto

    2009-01-01

    Pests like beetles, moths, fungus and mites normally attack stored products such as grains, spices, flours, brans and tobacco in bale. Among these pests the Sitophilus zeamais is one of the most important pests due its elevated potential of reproduction, infesting a great number of products, inducing great damages. This work had as objective to determine the efficacy of gamma radiation from Cobalt-60 as quarantine treatment for S. zeamais. The insects used in this experiment were reared in maize grains, at the Laboratorio de Artropodes of the Instituto Biologico/SP, on climatic room with 27 ± 2 deg C of temperature and relative humidity of 70 ± 5%. Samples containing 25 adult insects were put in acrylic recipients measuring 2.8cm x 2.8cm. Each treatment had four repetitions, in a total of 100 insects for treatment. They were irradiated with growing doses of gamma radiation: 0 (control); 0,25; 0,5; 0,75; 1,0; 1,25; 1,5; 1,75; 2,0; 2,25 2,5; 2,75; 3,0; 3,5 e 4,0 kGy, in a experimental irradiator of Cobalt-60, model Gammacell-220, located at the Centro de Tecnologia da Radiacoes - CTR of the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN/SP. After irradiation, the samples were transferred to plastic recipients measuring 3,5cm x 10cm, with perforated lids (to allow gaseous exchanges). After the irradiation the samples were kept in climatic room (27 ± 2 deg C and 70 ± 5%). The mortality of insects was evaluated 1 hour after the irradiation and also on the next 7 days. By the results obtained we can conclude that was the dose of 2.75 kGy that induced the immediate mortality for adult insects of the specie S. zeamais. (author)

  15. Activity distribution of a cobalt-60 teletherapy source

    International Nuclear Information System (INIS)

    Jaffray, D.A.; Munro, P.; Battista, J.J.; Fenster, A.

    1991-01-01

    In the course of quantifying the effect of radiation source size on the spatial resolution of portal images, a concentric ring structure in the activity distribution of a Cobalt-60 teletherapy source has been observed. The activity distribution was measured using a strip integral technique and confirmed independently by a contact radiograph of an identical but inactive source replica. These two techniques suggested that this concentric ring structure is due to the packing configuration of the small 60Co pellets that constitute the source. The source modulation transfer function (MTF) showed that this ring structure has a negligible influence on the spatial resolution of therapy images when compared to the effect of the large size of the 60Co source

  16. SSDL Argentina: Dosimetric intercomparison programme for cobalt 60 therapy units

    Energy Technology Data Exchange (ETDEWEB)

    Saravi, M; Papadopulos, S; Mugliaroli, H [Comision Nacional de Energia Atomica, Buenos Aires (Argentina)

    1996-08-01

    Thermoluminescence dosimeters (TLD) are widely used to verify absorbed dose delivered from radiation therapy beams. The Secondary Standard Dosimetry Laboratory (SSDL) of Argentina uses TLD for its mailed dose intercomparison programme for cobalt 60 radiation therapy units. Results obtained since 1978 as well as causes of dose discrepancies greater than 5% are analyzed. Results of the external quality control performed by the IAEA for this programme indicate that the dose evaluated by the SSDL TLD service for the participating centers is about 1% lower than that evaluated by the IAEA TLD service. This deviation is accepted taking on account that a {+-} 2% dose uncertainty for TLD dosimetry is reasonable. (author). 5 refs, 5 figs, 2 tabs.

  17. An Economic Analysis of Electron Accelerators and Cobalt-60 for Irradiating Food

    OpenAIRE

    Morrison, Rosanna Mentzer

    1989-01-01

    Average costs per pound of irradiating food are similar for the electron accelerator and cobalt-60 irradiators analyzed in this study, but initial investment costs can vary by $1 million. Irradiation costs range from 0.5 to 7 cents per pound and decrease as annual volumes treated increase. Cobalt-60 is less expensive than electron beams for annual volumes below 50 million pounds. For radiation source requirements above the equivalent of 1 million curies of cobalt-60, electron beams are more e...

  18. Preoperative cobalt60 irradiation delays the healing of rectal anastomoses in rats

    International Nuclear Information System (INIS)

    Fang, C.B.; Klug, W.A.; Capelhuchnik, P.

    2005-01-01

    The healing of colorectal anastomoses after irradiation therapy continues to be a major concern. The authors evaluated the healing of rectal anastomoses in a rat model after a preoperative 500-c Gy dose of cobalt 60 irradiation. Thirty-six male Wistar rats were divided into two equal groups: control (group A), and irradiation group (group B). Group B received a single 500-c Gy dose of irradiation, and a rectal resection and end-to-end anastomosis was performed in both groups on the seventh day after irradiation. Parameters of the healing process included bursting pressure and collagen content on the fifth, seventh, and fourteenth days after surgery. In the irradiation group, the mean bursting pressure on the fifth, seventh, and fourteenth days was 116, 218, and 273 mmHg, respectively. The collagen content assessed by histomorphometry was 9.0, 20.8, and 32%, respectively. In contrast, the control group had a mean bursting pressure of 175, 225 and 263 mmHg, and a collagen content of 17.8, 28.1, and 32.1%, respectively. The adverse effect of irradiation on healing was detectable only on the fifth postoperative day, as demonstrated by lower bursting pressure (P < 0.013) and collagen content (P < 0.008). However, there was no failure of anastomotic healing such as leakage or dehiscence due to irradiation. We conclude that a single preoperative 500-c Gy dose of irradiation delays the healing of rectal anastomosis in rats. (author)

  19. New formula for calculation of cobalt-60 percent depth dose

    International Nuclear Information System (INIS)

    Tahmasebi Birgani, M. J.; Ghorbani, M.

    2005-01-01

    On the basis of percent depth dose calculation, the application of - dosimetry in radiotherapy has an important role to play in reducing the chance of tumor recurrence. The aim of this study is to introduce a new formula for calculating the central axis percent depth doses of Cobalt-60 beam. Materials and Methods: In the present study, based on the British Journal of Radiology table, nine new formulas are developed and evaluated for depths of 0.5 - 30 cm and fields of (4*4) - (45*45) cm 2 . To evaluate the agreement between the formulas and the table, the average of the absolute differences between the values was used and the formula with the least average was selected as the best fitted formula. The Microsoft Excel 2000 and the Data fit 8.0 soft wares were used to perform the calculations. Results: The results of this study indicated that one amongst the nine formulas gave a better agreement with the percent depth doses listed in the table of British Journal of Radiology . The new formula has two parts in terms of log (A/P). The first part as a linear function with the depth in the range of 0.5 to 5 cm and the other one as a second order polynomial with the depth in the range of 6 to 30 cm. The average of - the differences between the tabulated and the calculated data using the formula (Δ) is equal to 0.3 152. Discussion and Conclusion: Therefore, the calculated percent depth dose data based on this formula has a better agreement with the published data for Cobalt-60 source. This formula could be used to calculate the percent depth dose for the depths and the field sizes not listed in the British Journal of Radiology table

  20. PENYERAPAN COBALT-60 DARI AIR OLEH TANAMAN KIAPU (Pistia stratiotes L.)

    OpenAIRE

    Lailatul Nuzzulul Safitri; Poppy Intan Tjahaja; Ida Bagus Made Suryatika

    2015-01-01

    Has conducted research Cobalt-60 radionuclide uptake by plants kiapu (Pistia stratiotes L.) found in many waters. The purpose of the study was to determine the value of the transfer factor on plant kiapu to Cobalt-60 in water. The study was conducted by growing plants on media kiapu gutter water in pots with the height 35 cm and diameter 11,5 cm containing Cobalt-60. The amount of Cobalt - 60 is absorbed and accumulated by the plant parts, i.e. roots and leaves, was observed by measuring the ...

  1. Research about combination of Gamma Knife and cobalt-60 radiation therapy to treat hypophysoma

    International Nuclear Information System (INIS)

    Xing Yueming; Zhao Xinping; Song Xiang; Wu Wei; Huang Bai

    2003-01-01

    Objective: To probe the therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiotherapy. Methods: 80 Hypophysoma patients who have been randomly grouped into two groups. Combination of Gamma Knife and cobalt-60 radiotherapy group and single Gamma knife group. Results: The therapeutic effectiveness of combination of Gamma Knife and cobalt-60 radiation therapy group was higher than that of single Gamma Knife group. Conclusion: The hospital that treat Hypophysoma with single Gamma Knife should add cobalt-60 radiotherapy in order to increase the local Hypophysoma dose

  2. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae)

    International Nuclear Information System (INIS)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25± 2 deg C, 70 ± 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  3. Degradation of the insecticide ethyl parathion in different environmental matrices by gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Luchini, Luiz Carlos

    1995-01-01

    This work studies the use of gamma radiation from cobalt-60 to induce parathion degradation in different matrices, as well as, quantified GC-NPD and identified by GC-MS, the radiolysis resulting products. Results show that the insecticide was completely degraded in aqueous solution after treatment with 1.0 kGy dosis in a dosis rate of 3.12 kGy h -1 . In methanol, parathion was completely degraded only with 30 kGy at 3.12 kGy h -1 . The metabolites detected after radiolysis were the same formed by biological degradation, i.e, p-nitrophenol, p-aminophenol, paraoxon and aminoparathion. The gamma radiation also degraded paraoxon which is the most toxic metabolite of parathion. It was verified that, not only the total radiation, but also the dosis rate supplied to the aqueous solution had a significant effect on the insecticide degradation, and the formation of metabolites occurred in a selective way respecting the dosis and dosis rate. Otherwise, the gamma radiation did almost not degraded the parathion adsorbed in solid matrices as rice, moist and dry soil, even using dosis of 5,30 and 50 kGy, respectively. The parathion yield and the dosis of gamma radiation needed for 50% reduction of the insecticide initial concentration in aqueous solution were also calculated and presented. Thus, it was verified that irradiation of parathion besides to be an important instrument for environmental decontamination of this pesticide in aqueous matrix, it allows the production of parathion metabolites for ecotoxicological studies. (author)

  4. An athymic mouse model to mimic cobalt-60 cutaneous radiation injury

    Energy Technology Data Exchange (ETDEWEB)

    Mosca, Rodrigo Crespo; Ferreira, Danilo Cardenuto; Napolitano, Celia Marina; Santin, Stefany Plumeri; Dornelles, Leonardo Dalla Porta; Alvarenga, Eluara Ortigoso; Mathor, Monica Beatriz, E-mail: rcmosca@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Propose: Cutaneous wound from irradiation is the most common complication in radiotherapy treatment, and can be lead to mortality. We describe an athymic mouse model to mimic cutaneous radiation injury by Cobalt-60. Methods: A protocol was including dosimetry with silicon diodes,10x10x5 cm arrangement made by four lead bricks and PVC pipe designed to immobilize the athymic mouse in order to irradiate one clamped back skin point that was subdivided in four parts. To get the measurements of dose rates on the arrangement in Panoramic Irradiator, it was used a silicon diode encased in an opaque protection for ambient light and connected to an electric cable, forming a dosing probe. The currents generated in diode sensitive volume as a function of time of exposure to gamma radiation coming from the radiator, with dose rate of 0,015 Gy/min in positions 1, 0,021 Gy/min in position 2, 0,55 Gy/min in position 3 and 1,45 Gy/min in position four. After the dosimetry, each athymic mouse was anesthetized using Xylazine and Ketamine dilution and entered into a PVC pipe and a small portion of skin (1 cm{sup 3}) was clamped. This tube was then fixed to arrangement and the athymic mouse was irradiate for 60 min, than it was being returned to its cage. Results: The wound was visualized in all animals and photographed after 5 days of irradiation, with the emergence of ulceration after 9 days. No systemic or lethal sequelae occurred or visualized in any animals. Late clinical signs included a wound healing after 22 days. Conclusion: While still being a baseline study, we created a new functional preclinical animal model that can be used for new therapies and may improve radiotherapy management. (author)

  5. An athymic mouse model to mimic cobalt-60 cutaneous radiation injury

    International Nuclear Information System (INIS)

    Mosca, Rodrigo Crespo; Ferreira, Danilo Cardenuto; Napolitano, Celia Marina; Santin, Stefany Plumeri; Dornelles, Leonardo Dalla Porta; Alvarenga, Eluara Ortigoso; Mathor, Monica Beatriz

    2013-01-01

    Propose: Cutaneous wound from irradiation is the most common complication in radiotherapy treatment, and can be lead to mortality. We describe an athymic mouse model to mimic cutaneous radiation injury by Cobalt-60. Methods: A protocol was including dosimetry with silicon diodes,10x10x5 cm arrangement made by four lead bricks and PVC pipe designed to immobilize the athymic mouse in order to irradiate one clamped back skin point that was subdivided in four parts. To get the measurements of dose rates on the arrangement in Panoramic Irradiator, it was used a silicon diode encased in an opaque protection for ambient light and connected to an electric cable, forming a dosing probe. The currents generated in diode sensitive volume as a function of time of exposure to gamma radiation coming from the radiator, with dose rate of 0,015 Gy/min in positions 1, 0,021 Gy/min in position 2, 0,55 Gy/min in position 3 and 1,45 Gy/min in position four. After the dosimetry, each athymic mouse was anesthetized using Xylazine and Ketamine dilution and entered into a PVC pipe and a small portion of skin (1 cm 3 ) was clamped. This tube was then fixed to arrangement and the athymic mouse was irradiate for 60 min, than it was being returned to its cage. Results: The wound was visualized in all animals and photographed after 5 days of irradiation, with the emergence of ulceration after 9 days. No systemic or lethal sequelae occurred or visualized in any animals. Late clinical signs included a wound healing after 22 days. Conclusion: While still being a baseline study, we created a new functional preclinical animal model that can be used for new therapies and may improve radiotherapy management. (author)

  6. Effects of cobalt-60 ionizing radiation on human erythrocyte and its membrane proteins

    International Nuclear Information System (INIS)

    Amancio, Francisco Fernandes

    1998-01-01

    Ionizing radiation has several uses, as sterilization and radiotherapy, by its effects on living beings. recently, it has been used, at relatively lower doses (25 Gy), on blood for transfusions, mainly to eliminate undesirable graft host reactions, for use in multi transfused or immunocompromised patients. Here, we study the effect of larger doses of cobalt-60 ionizing radiation (25-1600 Gy) on human erythrocytes, by cytometric, physiologic, biochemical and immunological methods, looking for its effects and its detection. The red cells presented a clear dose-dependent increase in this volume, when irradiated in doses higher than 200 Gy, more significant in stored blood, but without hemolysis. Osmotic fragility was increased only after irradiation of more than 400 Gy. By ektacytometry, there was a lower deformability of irradiated red cells, at low stress (0.3 Pa), similar to capillary flow, but without alteration in higher stress (3 Pa), found in cardiac chambers. By SDS-PAGE, it was demonstrated that irradiated isolated erythrocyte membranes had aggregation of spectrin molecules, and decay of bands with lower molecular mass. This effect could be attributed to the radiation-induced hydroxyl radical, by specific scavenger studies. Those modifications were both antigenic and immunogenic in experimental animals, and the induced antibodies recognizes, by ELISA and immunoblot, both native or irradiated membrane proteins. They recognize rather irradiated whole erythrocyte than native ones, by hemagglutination, indirect immunofluorescence or flow cytometry assays. Our data suggests that human red cells could be irradiated at higher doses than those usually employed, with possible effect on other contaminant pathogens, without loss of viability of its use in transfusions. After improvements, irradiation induced epitopes detection could be a new tool in biological dosimetry. (author)

  7. Practical and clinical considerations in Cobalt-60 tomotherapy

    Directory of Open Access Journals (Sweden)

    Joshi Chandra

    2009-01-01

    Full Text Available Cobalt-60 (Co-60 based radiation therapy continues to play a significant role in not only developing countries, where access to radiation therapy is extremely limited, but also in industrialized countries. Howver, technology has to be developed to accommodate modern techniques, in-clud-ing image guided and adaptive radiation therapy (IGART. In this paper we describe some of the practical and clinical considerations for Co-60 based tomotherapy by comparing Co-60 and 6 MV linac-based tomotherapy plans for a head and neck (HandN cancer and a prostate cancer case. The tomotherapy IMRT plans were obtained by modeling a MIMiC binary multi-leaf collimator attached to a Theratron-780c Co-60 unit and a 6 MV linear accelerator (CL2100EX. The EGSnrc/BEAMnrc Monte Carlo (MC code was used for the modeling of the treatment units with the MIMiC collimator and EGSnrc/DOSXYZnrc code was used for beamlet dose data. An in-house inverse treatment planning program was then used to generate optimized tomotherapy dose distributions for the H and N and prostate cases. The dose distributions, cumulative dose area histograms (DAHs and dose difference maps were used to evaluate and compare Co-60 and 6 MV based tomotherapy plans. A quantitative analysis of the dose distributions and dose-volume histograms shows that both Co-60 and 6 MV plans achieve the plan objectives for the targets (CTV and nodes and OARs (spinal cord in HandN case, and rectum in prostate case.

  8. Radiological safety aspects during handling of adjuster rod (cobalt-60) samples at Cirus

    International Nuclear Information System (INIS)

    Yadav, R.K.B.; Prasad, S.K.; Khuspe, R.R.; Babu, K.S.; Kamble, M.K.; Deshpande, S.B.; Srivastava, Alok; Ramesh, N.; Sharma, R.C.

    2008-01-01

    Cobalt -60 produced from the irradiation of the 59 Co capsules in adjuster rod of Cirus is used in many medical and industrial applications such as radiation therapy, sterilization of agricultural products, sterilization of medical equipment, industrial gamma exposure devices, nucleonic gauging sources etc. Two adjuster rods used for adjusting small reactivity loads (3.5 mk at 40 MW) in reactor contain thirty 59 Co slugs each. The 59 Co slugs are in the form of small capsules. These slugs were irradiated for nearly 3 years of full power operation. Since the amount of activity handled in the adjuster rod is very high (35 - 40 kCi), adequate radiological safety coverage is to be provided during the transfer of adjuster rod from the reactor pile to Tray Rod Facility (TRF) and during remote handling and loading of adjuster rod samples in shipping flask at TRF. Radiation fields observed are 0.4 - 3.0 Gy/h. In Cirus, falling of Adjuster rod from vertical flask at top of pile could result in declaration of evacuation emergency due to potential hazards associated with the high radiation field (∼26 Gy/h at 1m) of 60 Co slugs. Entire process of remote handling is viewed through lead glass and movement of samples is carried out with the help of a pair of master slave manipulator (MSM) arms. TRF with full samples give a radiation background of 0.2 - 20 mGy/h, requiring control of movement of personnel in the area. This paper explains in detail about the health physics aspects during handling of adjuster rod from reactor pile to TRF and back to pile, unloading and loading of radioisotope samples, operational radiation protection experience gained and collective dose consumed for the above transfer and loading job. The collective dose consumed in the handling of two adjuster rods is 8.7 per-mSv. (author)

  9. Cytogenetic characterization of low-dose hyper-radiosensitivity in Cobalt-60 irradiated human lymphoblastoid cells

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Gnanada S. [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States); Joiner, Michael C. [Department of Radiation Oncology, Wayne State University, Detroit, MI 48201 (United States); Tucker, James D., E-mail: jtucker@biology.biosci.wayne.edu [Department of Biological Sciences, Wayne State University, Detroit, MI 48202 (United States)

    2014-12-15

    Highlights: • Human cells were irradiated in G1 or G2 and evaluated for micronuclei and bridges. • Cells irradiated in G2 but not in G1 exhibit low dose hyper-radiosensitivity. • Response curves of cells irradiated in G2 do not fit a linear-no-threshold model. • Response curves of cells irradiated in G1 fit a linear-no-threshold model. - Abstract: The dose-effect relationships of cells exposed to ionizing radiation are frequently described by linear quadratic (LQ) models over an extended dose range. However, many mammalian cell lines, when acutely irradiated in G2 at doses ≤0.3 Gy, show hyper-radiosensitivity (HRS) as measured by reduced clonogenic cell survival, thereby indicating greater cell lethality than is predicted by extrapolation from high-dose responses. We therefore hypothesized that the cytogenetic response in G2 cells to low doses would also be steeper than predicted by LQ extrapolation from high doses. We tested our hypothesis by exposing four normal human lymphoblastoid cell lines to 0–400 cGy of Cobalt-60 gamma radiation. The cytokinesis block micronucleus assay was used to determine the frequencies of micronuclei and nucleoplasmic bridges. To characterize the dependence of the cytogenetic damage on dose, univariate and multivariate regression analyses were used to compare the responses in the low- (HRS) and high-dose response regions. Our data indicate that the slope of the response for all four cell lines at ≤20 cGy during G2 is greater than predicted by an LQ extrapolation from the high-dose responses for both micronuclei and bridges. These results suggest that the biological consequences of low-dose exposures could be underestimated and may not provide accurate risk assessments following such exposures.

  10. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    International Nuclear Information System (INIS)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz; Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana

    2011-01-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and α-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h -1 ) and electron beam (2.9 kGy.s -1 ). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and α-tocopherol (A2). (author)

  11. Effect of antioxidants on thiobarbituric acid reactive substances of mechanically de boned chicken meat irradiated with ionizing radiation: cobalt-60 and electron beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Poliana de Paula; Azevedo, Heliana de; Pomarico Neto, Walter; Roque, Claudio Vitor; Brusqui, Armando Luiz, E-mail: hgomes@cnen.gov.b, E-mail: pbrito@cnen.gov.b, E-mail: cvroque@cnen.gov.b, E-mail: abrusqui@cnen.gov.b [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Haguiwara, Marcia Mayumi Harada; Miyagusku, Luciana, E-mail: marciamh@ital.gov.b, E-mail: lucianam@ital.gov.b [Food Technology Institute (ITAL), SP (Brazil). Meat Technology Center

    2011-07-01

    Samples of MDCM with skin were divided into three groups: control (without antioxidants), Antioxidant 1 - A1 (0.3% Sodium Polyphosphate and Sodium Erythorbate 0.05%) and Antioxidant 2 - A2 (Rosemary Extract 0.02% and {alpha}-Tocopherol 0.01%). The three batches of samples were divided into nine groups: no antioxidant and non-irradiated (Cn/I), with antioxidant A1 and non-irradiated (A1n/I), with antioxidant A2 and non-irradiated (A2n/I) without antioxidant and irradiated in Cobalt-60 source (CCo), with antioxidant A1 irradiated in Cobalt 60 source (A1Co) with antioxidant A2 irradiated in Cobalt-60 source (A2Co) with antioxidant A1 irradiated in Electron beam (A1Eb) and with antioxidant A2 irradiated in Electron beam (A2Eb). Each 100 g sample was conditioned in a transparent, low density polyethylene oxygen permeable bag, frozen overnight at a temperature of -18 +- 1 deg C in a chamber, and irradiated in this state, maintaining the temperature low with dry ice. The samples were irradiated with a dose of 3.0 kGy, used two sources of radiation: Cobalt-60 (3.1 kGy.h{sup -1}) and electron beam (2.9 kGy.s{sup -1}). After this process, the samples were evaluated during the refrigeration period (2 +- 1 deg C) for 11 days for the following analysis: total psychotropic bacteria count, thiobarbituric acid reactive substances (TBARS). The addition of antioxidants was able to reduce lipid oxidation caused by the irradiation. There were no differences between the radiation sources used in the same parameters. The better antioxidants mixture in the TBARS reducing it was rosemary extract and {alpha}-tocopherol (A2). (author)

  12. Evaluation of shelf life of tomatoes after using radiation with cobalt-60 source

    International Nuclear Information System (INIS)

    Vicalvi, Maria Claudia V.; Solidonio, Evelyne G.; Melo, Patryk; Silva, Marcio Albuquerque da; Junior, Carlos Eduardo de O.C.; Silva, Glezia Renata da; Sena, Kesia Xisto F.R. de; Colaco, Waldeciro

    2013-01-01

    Tomato is one of the most consumed fruits in the world and also one of the agricultural products with most losses due to its high perishability. The objective of this research was to evaluate the increased length of shelf life of tomatoes sold in the CEASA-PE through the use of radiation in doses of 1, 1.5 and 2 kGy with Cobalt-60 source. The study used three lots of 100 tomatoes each. Of which, 25 of them were used as the control group and 75 were irradiated with one of 3 different doses. The evaluation of the shelf life of tomatoes before and after use of the radiation was made from the observation of the visual aspects of the initiation of the fruit sto decay. The samples were analyzed at of every seven days. The fruit treated as the control group of the first batch were viable with no signs of decay for more than one month wrapped in sterile plastic wrap and stored at environment temperature ± 25 deg C. It was observed that at the dose of 1.0 kGy there was a delay in the induction of shelf life over 14 days. When used a dose of 1.5 kGy there was an increase of 30 days on shelf life compared with the control group. At a dose of 2.0 kGy, the tomatoes have a shelf life of 92 days. In the second batch of fruits, the duration of tomatoes of the control group was 40 days. At a dose of 1.0 kGy was an increase of 15 days compared to control fruits. When applying the dose of 1.5 kGy, the lifetime of the fruit was 70 days and at the dose of 2.0 kGy fruits were of 106 days starting from the initial date of experiment. The third and final batch,the lifetime of the fruits were not higher than those found in previous batches, the control group had a permanence of 14 days. At the dose of 1.0 kGy, there was the additional 10 days compared to the control group. At a dose of 1.5 kGy was observed that the fruits lasted 35 days starting from the initial day of the experiment and the tomatoes that were irradiated at 2.0 kGy the duration was 45 days from the start date of the

  13. Evaluation of shelf life of tomatoes after using radiation with cobalt-60 source

    Energy Technology Data Exchange (ETDEWEB)

    Vicalvi, Maria Claudia V.; Solidonio, Evelyne G.; Melo, Patryk; Silva, Marcio Albuquerque da; Junior, Carlos Eduardo de O.C.; Silva, Glezia Renata da; Sena, Kesia Xisto F.R. de; Colaco, Waldeciro, E-mail: claudiavicalvi@hotmail.com, E-mail: k.xisto@gmail.com, E-mail: wcolaco@ufpe.com.br [Universidade Federal de Pernanbuco (UFPE), Pernambuco, PE (Brazil)

    2013-07-01

    Tomato is one of the most consumed fruits in the world and also one of the agricultural products with most losses due to its high perishability. The objective of this research was to evaluate the increased length of shelf life of tomatoes sold in the CEASA-PE through the use of radiation in doses of 1, 1.5 and 2 kGy with Cobalt-60 source. The study used three lots of 100 tomatoes each. Of which, 25 of them were used as the control group and 75 were irradiated with one of 3 different doses. The evaluation of the shelf life of tomatoes before and after use of the radiation was made from the observation of the visual aspects of the initiation of the fruit sto decay. The samples were analyzed at of every seven days. The fruit treated as the control group of the first batch were viable with no signs of decay for more than one month wrapped in sterile plastic wrap and stored at environment temperature ± 25 deg C. It was observed that at the dose of 1.0 kGy there was a delay in the induction of shelf life over 14 days. When used a dose of 1.5 kGy there was an increase of 30 days on shelf life compared with the control group. At a dose of 2.0 kGy, the tomatoes have a shelf life of 92 days. In the second batch of fruits, the duration of tomatoes of the control group was 40 days. At a dose of 1.0 kGy was an increase of 15 days compared to control fruits. When applying the dose of 1.5 kGy, the lifetime of the fruit was 70 days and at the dose of 2.0 kGy fruits were of 106 days starting from the initial date of experiment. The third and final batch,the lifetime of the fruits were not higher than those found in previous batches, the control group had a permanence of 14 days. At the dose of 1.0 kGy, there was the additional 10 days compared to the control group. At a dose of 1.5 kGy was observed that the fruits lasted 35 days starting from the initial day of the experiment and the tomatoes that were irradiated at 2.0 kGy the duration was 45 days from the start date of the

  14. Some safety aspects during the replacement of Cobalt-60 sources in teletherapy

    International Nuclear Information System (INIS)

    Milu, C.

    1998-01-01

    Some recent radiation protection problems arose during the replacement of the old Cobalt-60 sources in teletherapy in Romania. There are pointed out the potential radiation risks for the population and the lack of appropriate regulation for the field. (author)

  15. Process of contamination of two trophic dulcaquicole chains by cobalt 60. I

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.; Foulquier, L.

    1978-01-01

    In order to evaluate Cobalt 60 behavior in freshwater ecosystems, two food chains including different nutritionally interdependent species in a natural environment were defined. This article covers the dynamics of water-borne contamination in the species. (Auth.)

  16. Studi Standarisasi Radioterapi Cobalt-60 Terhadap Kuantitas Sel Darah Pada Penderita Kanker Serviks (Cancer Cervics Di Rsup Sanglah Denpasar

    Directory of Open Access Journals (Sweden)

    Retianingsih Oeta Ulan

    2017-09-01

    Full Text Available After doing research with Title Study of Cobalt-60 radiotherapy Standards Against Quantity Blood Cells In Patients with Cervical Cancer (Cancer Cervics at Sanglah Hospital in Denpasar. This study uses secondary data such as a complete blood from each patient with cervical cancer in 2015 that radiotherapy with fractionation method. The amount of patient data used in this study is 5 pieces. The quantity of blood cells that are analyzed include RBC, HGB, WBC and WBC Components (LY, EO, EO, BA, NE, MO. Fractionation dose is 800-5800cGy. The results of data analysis showed that each blood cell components are still within the range of 2-50%, so a method of radiotherapy is still fit for use.

  17. Sterilization of silver acidium pipemedicum skin for the treatment of burns by radioactive cobalt-60-γray

    International Nuclear Information System (INIS)

    Zeng Defeng; Cao Fengsheng; Chen Qinglong; Li Guohui; Su Ziyi; Cao Yong; Wu Wenqing; Qiu Zeyi; Chen Zhanxian

    1995-01-01

    The radiated silver acidum pipemedicum skin (RSAPS) was made of 0.4-0.8mm laminal skin from healthy white pig, which was infiltrated in norfloxacin and silver nitrate, packed with the filkm bag of alummium poil and radiated by cobalt-60γ-ray for sterilization at the dosage of 27.92-35.31Gy/min for a total dose of 25KGY, RSAPS was very effective in sterilization and had no bad effect on elasticity, adhesion, water permeability, and structure of pig skin. So it is highly appreciated by the patients and medical personnel for its convenience of usage and has gained good social and economic beneficial results. (Author)

  18. Hematological changes in sheep inoculated with natural and Cobalt60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    International Nuclear Information System (INIS)

    Netto, D.P.; Alfieri, A.A.; Balarim, M.R.S.; Chiacchio, S.B.; Bicudo, P.L.; Nascimento, N.

    2004-01-01

    Natural (NV) and Cobalt 60 -irradiated (IrV) Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 m M, p H 3.0) and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV) and the other natural venom (NV). Three antigen doses (venom) were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD 50 for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/μl indicates that slight leucocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the N V group, showing its greater toxicity. (author)

  19. Seed germination of peanuts irradiated with cobalt (60CO)

    International Nuclear Information System (INIS)

    Alves, Niedja Marrize C.; Almeida, Francisco de Assis C.; Gomes, Josivanda P.; Pessoa, Elvira B.; Leal, Artur S. Cavalcanti

    2010-01-01

    This work was realized to evaluate the effect of gamma irradiation ( 60 Co) at doses 0, 0.50, 1.00, 1.50, 2.00, 2.50, 3.00 and 4.00 kGy, on germination of seeds of peanut, cultivar BR1. Irradiation Department of Nuclear, UFPE, where he received after the irradiation, they were stored in packing of PET and polyethylene braided with a time of 90 days. Through the results, obtained monthly, concluded that the dose of 0.5 kGy was effective in the germination of seeds of peanut, not affecting its power of germination and overcoming the witness within 30 to 60 days. (author)

  20. Effects of gamma radiation of Cobalt-60 on arabica and conillon seeds coffea: physic-chemistry evaluation

    International Nuclear Information System (INIS)

    Silva, Marcus Henriques da

    2012-01-01

    Brazil is the largest producer and exporter of coffee in the world. The coffee bean is one of the main products of the Brazilian trade balance. Two species of coffee are the most economically important: the Coffea arabica L. and Coffea canephora Pierre is the largest representative of the Coffea canephora Pierre is the coffea conillon. Food irradiation is an area of research that aims to increase the shelf life of foods and controlling pests. This study aimed to verify the physicochemical variables of Arabica coffee and conillon were affected when exposed to doses of gamma radiation from cobalt-60. The samples were provided by Polo in Coffee Quality Technology, Federal University of Lavras - UFLA. The coffee samples were subjected to irradiation doses: 0 (control), 5 kGy and 10 kGy, a multipurpose irradiator of IPEN - Research Institute of Nuclear Energy and the University of São Paulo, at a rate of 7.5 kGy / hour. For irradiation the samples were vacuum-packed in appropriate packaging aluminised. After the process of irradiation the samples were stored at a temperature of 15 ± 1 deg C and relative humidity of 17 ± 1%. The following analyzes were performed: levels of total sugars, glucose, sucrose, caffeine, humidity, pH, total acidity, electrical conductivity and fibers. Analyses were performed 1, 30, 60 and 90 days after irradiation, and the results were submitted to analysis of variance and means were compared by Tukey test at 5%. It was observed that the analysis results of the samples irradiated with 5 kGy and 10 kGy showed values similar to the control. It was concluded that irradiation did not induce deleterious effects on arabica coffee seeds and conillon irradiated with 5 kGy and 10 kGy to 90 days after irradiation. (author)

  1. Lethal dose determination of Cobalt-60 for adult Tribolium castaneum (Coleoptera: Tenebrionidae) and Cryptolestes ferrugineus (Coleoptera: Laemophloeidae)

    International Nuclear Information System (INIS)

    Farias, Anderson Aparecido; Potenza, Marcos Roberto; Reis, Fabricio Caldeira; Sato, Mario Eidi

    2015-01-01

    The insect infestation is a major problem in the grain storage. The pesticides are most widely used method for disinfestation and prevention. Treatment with gamma irradiation may increase the product shelf life without encountering formation of waste can be used in packaged foods and ready for commercialization, representing an important alternative to the use of pesticides. This study aimed to determine the immediate lethal dose of gamma radiation for adults of Tribolium castaneum and Cryptolestes ferrugineus. The study was conducted in the Instituto Biologico and the radiations held at the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN, Sao Paulo city, using a multipurpose irradiator Cobalt-60 with 3.31 dose rate and 3.23 kGy in months of November/2014 and January/2015. Each experimental unit consisted of 20 adult insects, confined in a 10 mL polyethylene container. The experimental plots in number 10 per dose were subjected to increasing doses of gamma radiation: 0; 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.00; 2:50 and 3.00 kGy. Mortality was assessed within two to four hours after irradiation. The data were submitted to Probit analysis, using the POLO PLUS program. The LD90 to control 90% (LD90) to control adult Cryptolestes ferrugineus and Tribolium castaneum were 2.73 and 2.91 kGy, respectively. (author)

  2. Lethal dose determination of Cobalt-60 for adult Tribolium castaneum (Coleoptera: Tenebrionidae) and Cryptolestes ferrugineus (Coleoptera: Laemophloeidae)

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Anderson Aparecido, E-mail: potenza@biologico.sp.gov.br [Instituto Biologico, Centro de Pesquisa e Desenvolvimento de Protecao Ambiental, Sao Paulo, SP (Brazil); Potenza, Marcos Roberto, E-mail: fcreis@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Reis, Fabricio Caldeira; Sato, Mario Eidi, E-mail: mesato@biologico.sp.gov.br [Instituto Biologico, Centro Experimental Central, Laboratorio de Acarologia, Campinas, SP (Brazil)

    2015-07-01

    The insect infestation is a major problem in the grain storage. The pesticides are most widely used method for disinfestation and prevention. Treatment with gamma irradiation may increase the product shelf life without encountering formation of waste can be used in packaged foods and ready for commercialization, representing an important alternative to the use of pesticides. This study aimed to determine the immediate lethal dose of gamma radiation for adults of Tribolium castaneum and Cryptolestes ferrugineus. The study was conducted in the Instituto Biologico and the radiations held at the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN, Sao Paulo city, using a multipurpose irradiator Cobalt-60 with 3.31 dose rate and 3.23 kGy in months of November/2014 and January/2015. Each experimental unit consisted of 20 adult insects, confined in a 10 mL polyethylene container. The experimental plots in number 10 per dose were subjected to increasing doses of gamma radiation: 0; 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.00; 2:50 and 3.00 kGy. Mortality was assessed within two to four hours after irradiation. The data were submitted to Probit analysis, using the POLO PLUS program. The LD90 to control 90% (LD90) to control adult Cryptolestes ferrugineus and Tribolium castaneum were 2.73 and 2.91 kGy, respectively. (author)

  3. Effects of gamma radiation from Cobalt-60 on pequi fruits (Caryocar brasiliense Camb.)

    International Nuclear Information System (INIS)

    Santos, Marcio Ramatiz Lima dos

    2008-01-01

    The aim of this work was to evaluate gamma radiation effects from Cobalt-60 on post harvest characteristics of pequi fruits (Caryocar brasiliense Camb.). Brazilian savannah is the second biome of American Continent and concentrate a lot of plants and animal species. Many plants and their fruits are still unknown of Brazilian population. Just now, they are gained attention of researchers due their nutritional properties, between then is the pequi fruits. Fruits come from Goias State was classified, washed and processed to separate the endocarp (edible part) from pericarp. The endocarps were packing in polyethylene bags with 150 g, labeled and submitted to radiation process (0.0, 0.4, 0.6 and 1.0 kGy doses) on multipurpose irradiator located in IPEN/USP. The samples were analyzed to chemical (pH, trititable acidity, Deg Brix, ratio TSS/TTA, lipids, ash, humidity, protein, soluble and insoluble fiber, total carotenoids and antioxidant activity) and physical properties (loss weight, texture and color). The loss humidity was proportional to radiation applied doses, the highest loss was observed on fruits to 1.0 kGy doses. Soluble fiber and protein showed no significant differences between treatments. Ash, insoluble fiber, dry matter and lipids showed little significant differences. Significant decrease of the pH values was observed for the irradiated samples in relation to control. Irradiated samples texture showed significant increase compared to control, but showed no significant differences between applied doses. The higher value for texture was (39.89 Newton g-1) for 0.6 kGy dose. Total soluble solids (TSS) showed a significant decrease compared to control, but was not significant between applied treatments. Titratable acidity showed a significant decrease for irradiated samples compared to control for all doses, but it was not significant between treatments. The ratio TSS/TTA showed no significant differences compared to control, only for irradiated fruits at 0.6 kGy

  4. Effect of the gamma radiation of cobalt 60 on the beta carotids present in the carrot

    International Nuclear Information System (INIS)

    Perez Lopez, Sergio Victor Hugo

    1997-01-01

    In the present work it was investigated the effect of the gamma radiation of cobalt 60 on the beta carotid's in the carrot (daucus carota), using for it three different radiation dose (100, 150 and 200 kilo-rad) and analyzing them by means of the liquid chromatography technique of high resolution (HPLC)

  5. Point kernel technique for calculating dose rates due to cobalt-60 hot particles

    International Nuclear Information System (INIS)

    Thornhill, M.J.; McCarthy, J.T.; Morrissette, R.R.; Leach, B.N.

    1989-01-01

    This paper reports on a computer code called BETA that has been developed by health physicists at the Vermont Yankee Nuclear Power Station which accounts for the mass and size of hot particles of Cobalt-60, and therefore corrects the Loevinger-based dose calculation for self-absorption

  6. Safety analysis report: packages cobalt-60 shipping cask (packaging of radioactive and fissile materials)

    International Nuclear Information System (INIS)

    Evans, J.E.; Langhaar, J.W.

    1973-07-01

    Safety Analysis Report DPSPU-73-124-1 replaces DPSPU-69-124-1 and Supplement 1 to permit shipment of 350,000 curies of 60 Co (maximum) in cobalt-60 shipping casks in compliance with 10 CFR Part 71, Packaging of Radioactive Materials for Transport

  7. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of cobalt 60 give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of Co60 has created an insurance Quality System which insures the maximum of security for the user. (author)

  8. Effect of cobalt-60 radiation on response to endodontic therapy in monkeys

    International Nuclear Information System (INIS)

    Matson, J.E.; Patterson, S.S.; Kafrawy, A.H.; Hornback, N.B.; Shidnia, H.

    1978-01-01

    Response of teeth that had received therapeutic doses of Cobalt-60 radiation to endodontic therapy were investigated in three monkeys. The results indicated no appreciable effect of the irradiation on the response to root canal treatment aside from reduction in osteoblastic activity

  9. An economic benefit analysis on the cobalt-60 irradiation facility of Beijing Radiation Research Center

    International Nuclear Information System (INIS)

    Wang Binlin

    1995-01-01

    The peculiarity, the investment and annual operating cost of the 3.7 x 10 16 Bq (MCi) cobalt-60 irradiation facility at Beijing Radiation Application Research Centre are described. Its economic benefits each year are analyzed according to several year operating practice. Some related questions on carrying out radiation processing are raised and discussed. (author)

  10. Use of gamma radiation of Cobalt-60 aiming at the quarentenary treatment and the sterilization of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae)

    International Nuclear Information System (INIS)

    Silva, L.K.F.; Arthur, V.; Nava, D.E.; Parra, J.R.P.

    2007-01-01

    The objective of this work was verify the influence of gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham (Lepidoptera: Elachistidae). For this research, insects were irradiated in all phases of their life cycle with doses varying from 0 to 600 Gy and they were maintained at the temperature of 25 +/- 2 deg C, relative humidity of 70 +/- 10% and photofase of 14 h. The species was reared on natural diet, avocado seeds, variety Breda. According to the obtained results, was verified that the lethal dose of gamma radiation to S. catenifer larvae and pupae was of 300 Gy. The sterile dose for upcoming adults from irradiated S. catenifer larvae, was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The use the gamma radiation as treatment quarentine of S. catenifer was efficient, should be treated them with doses able to promote the sterilization of insect, without committing your qualities physical-chemistries and sensorial of fruits. Therefore, is suggested the treatment with the dose of 50 Gy for fruits infested with eggs and 150 Gy for fruits infested with larvae and pupas of S. catenifer. For use the sterile insect technique is recommended the irradiation of pupas and adults with doses of 150 Gy and 200 Gy, respectively [pt

  11. A laboratory and field evaluation of the mobility of cobalt-60/EDTA

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Kirkham, R.R.; Swanson, J.L.

    1983-01-01

    We have observed a time and soil type dependence in the ability of the organic complexant EDTA to keep cobalt-60 in solution. Test results indicate that short-term adsorption tests lasting 5 days or less can be misleading. In short-term tests using cobalt-60/EDTA and soil from the Hanford site, low sorption in batch tests and high mobility in column tests were observed. During long-term batch test using cobalt-60/EDTA, the percentage of cobalt remaining in solution decreased from 90% after 7 days to less than 10% after 500 days. In laboratory and field column tests where low water flow rates allowed long contact time, virtually no cobalt movement was observed even though in the field test tritium was transported over 4 meters. Long-term batch tests using cobalt-60/EDTA and soil from Savannah River burial grounds showed that cobalt remainin in solution dropped to 30% of the total cobalt added after 5 days and to less than 1% after 15 days. Batch tests using soil from Oak Ridge burial grounds were less dramatic showing cobalt in solution decreasing from 90% after 5 days to 70% after 35 days. The cobalt-60/EDTA complex appears to be dissociating and leaving uncomplexed cobalt which is readily sorbed. The dissociation seems to be rather complete in Hanford and Savannah River soil but limited in the Oak Ridge soil. The implication to waste management is that the potential for transport of cobalt by EDTA may not be as serious at all burial sites as once thought

  12. Cobalt-60 Machines and Medical Linear Accelerators: Competing Technologies for External Beam Radiotherapy.

    Science.gov (United States)

    Healy, B J; van der Merwe, D; Christaki, K E; Meghzifene, A

    2017-02-01

    Medical linear accelerators (linacs) and cobalt-60 machines are both mature technologies for external beam radiotherapy. A comparison is made between these two technologies in terms of infrastructure and maintenance, dosimetry, shielding requirements, staffing, costs, security, patient throughput and clinical use. Infrastructure and maintenance are more demanding for linacs due to the complex electric componentry. In dosimetry, a higher beam energy, modulated dose rate and smaller focal spot size mean that it is easier to create an optimised treatment with a linac for conformal dose coverage of the tumour while sparing healthy organs at risk. In shielding, the requirements for a concrete bunker are similar for cobalt-60 machines and linacs but extra shielding and protection from neutrons are required for linacs. Staffing levels can be higher for linacs and more staff training is required for linacs. Life cycle costs are higher for linacs, especially multi-energy linacs. Security is more complex for cobalt-60 machines because of the high activity radioactive source. Patient throughput can be affected by source decay for cobalt-60 machines but poor maintenance and breakdowns can severely affect patient throughput for linacs. In clinical use, more complex treatment techniques are easier to achieve with linacs, and the availability of electron beams on high-energy linacs can be useful for certain treatments. In summary, there is no simple answer to the question of the choice of either cobalt-60 machines or linacs for radiotherapy in low- and middle-income countries. In fact a radiotherapy department with a combination of technologies, including orthovoltage X-ray units, may be an option. Local needs, conditions and resources will have to be factored into any decision on technology taking into account the characteristics of both forms of teletherapy, with the primary goal being the sustainability of the radiotherapy service over the useful lifetime of the equipment

  13. Experimental determination of gamma radiation effect from cobalt 60 on the viscosity of SSBR-B polymer

    International Nuclear Information System (INIS)

    Santos, L.G. dos; Silva Filho, E.

    1989-01-01

    Samples of the polymer known as SSBR-B (Solution Styrenne Butadiene Rubber-Blockade) were irradiated with gamma rays from a 60 Co source. Viscosity analysis performed by using the method of Ostwald Showed that the viscosity remains about constant for doses in the range of zero to 11560 Gray (Gy). For doses greater than 11560 Gy the viscosity increases. This result characterizes an irradiation induced hardening of the polymer. (author) [pt

  14. Use of low doses of cobalt 60 gamma radiation on beet (Beta vulgaris L.), carrot (Daucus carota L.) and radish (Raphanus sativus L.) seed to stimulate increase yield

    International Nuclear Information System (INIS)

    Bovi, Jose Eduardo

    2000-01-01

    The research had the aim of evaluating the effects of low doses of Cobalt-60 gamma radiation on seeds of radish (Raphanus sativus L.) cultiva Champion, cultivars Nantes Forto (european origin) and Brasilia (Rio Grande do Sul origin) carrot (Daucus carota L. var. sativus (Hoffm.) Thell), and red beet (Beta vulgaris L.) cultivar Tall Top Early Wonder before sowing, its effects on plant growth, on the yield and roots storage of two tillages: with sowing in the same day of radiation and six days after radiation seeds. The data showed that the seeds radiation did not interfered negatively on plants growth, and the species presented differences as roots production and doses on both plantation: radish with 5,0 Gy and 2,5 Gy doses respectively to the first and the second sowings, Brasilia carrot with 2,5 Gy dose to both sowings. Nantes carrot with 2,5 Gy and 5,0 Gy respectively to the first and the second sowings, and beet with 7,5 Gy and 5,0 Gy respectively to the first and the second plantations. There is not statistics difference by Tukey test (5% and 1%) and none relation between seeds radiation and loss weight on roots storage. (author)

  15. Radiological shielding of cobalt-60 teletherapy facility at Komfo Anokye Teaching Hospital, Kumasi, Ghana

    International Nuclear Information System (INIS)

    Addison, E.K.T.; Kitcher, H.W.; Kyere, A.W.K.; Nani, E.K.

    2003-01-01

    The radiological shielding of the radiotherapy unit, oncology directorate, Komfo Anokye teaching hospital, has been assessed based on the workload and occupancy factors, in addition to the technical and performance specification of the cirus cobalt-60 equipment. Aspects relating to the design of treatment room were described. Calculations were based on NCRP report 49 and measurements were carried out on the structural shielding design of the cobalt-60 unit by the standard method prescribed in the NCRP report 49. This study was carried out to evaluate the adequacy of the shielding put in place to ensure the safety of the staff, public and oncological patients. The results obtained and measurements made, all fall below the regulatory effective dose limit of 20 mSv per year for staff and 1 mSv per year for the public (author)

  16. The role of Cobalt-60 in modern radiation therapy: Dose delivery and image guidance

    Directory of Open Access Journals (Sweden)

    Schreiner L

    2009-01-01

    Full Text Available The advances in modern radiation therapy with techniques such as intensity-modulated radiation therapy and image-guid-ed radiation therapy (IMRT and IGRT have been limited almost exclusively to linear accel-erators. Investigations of modern Cobalt-60 (Co-60 radiation delivery in the context of IMRT and IGRT have been very sparse, and have been limited mainly to computer-modeling and treatment-planning exercises. In this paper, we report on the results of experiments using a tomotherapy benchtop apparatus attached to a conventional Co-60 unit. We show that conformal dose delivery is possible and also that Co-60 can be used as the radiation source in megavoltage computed tomography imaging. These results complement our modeling studies of Co-60 tomotherapy and provide a strong motivation for continuing development of modern Cobalt-60 treatment devices.

  17. Dosimetry of normal and wedge fields for a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Tripathi, U.B.; Kelkar, N.Y.

    1980-01-01

    A simple analytical method for computation of dose distributions for normal and wedge fields is described and the use of the method in planning radiation treatment is outlined. Formulas has been given to compute: (1) depth dose along central axis of cobalt-60 beam, (2) dose to off-axis points, and (3) dose distribution for a wedge field. Good agreement has been found between theoretical and experimental values. With the help of these formulae, the dose at any point can be easily and accurately calculated and radiotherapy can be planned for tumours of very odd shape and sizes. The limitation of the method is that the formulae have been derived for 50% field definition. For cobalt-60 machine having any other field definition, appropriate correction factors have to be applied. (M.G.B.)

  18. Sedimentation of cobalt-60 and caesium-137 released in Tvaeren, a Baltic bay

    International Nuclear Information System (INIS)

    Ramberg, L.

    1984-01-01

    The amounts of cobalt-60 and caesium-137 bound in the sediment in a bay off the Studsvik research station were determined. Of the cumulative released activity during 22 years, 19% of 60 Co and 1.8% of 137 Cs were found in the sediments within an area of 23 km 2 . The rate of input through sedimentation and the loss rate through physical decay were of the same order in 1981 and were close to steady state for 60 Co while for 137 Cs they had only reached 30% of that level. The sedimentation coefficients calculated for the bay were 6.5 year -1 for 60 Co and 0.49 year -1 for 137 Cs, higher values than many published previously. Cobalt-60 seemed to precipitate close to the outlet and to migrate near the bottom as bed-load. (author)

  19. Conceptual design of a conveyor system for the Philippine multipurpose cobalt-60 gamma irradiation facility

    International Nuclear Information System (INIS)

    Borras, A.M.

    1992-01-01

    The Multipurpose Cobalt-60 Gamma Irradiation Facility at the PNRI presently utilizes the batch irradiation method using turntables to rotate the product boxes. The target materials or products are being carried manually or with the use of pushcart through the personnel maze. This paper presents a conceptual design for the best suitable product-handling or conveyor system for the Philippine Multipurpose Cobalt-60 Gamma Irradiation Facility. The main irradiation conveyor line shall be a 55 cm x 200 cm slat-type conveyor made of SUS 304 material that could be operated in a semi-batch continuous flow and/or shuffle-dwell method with a tact-time range of 10 min to 7 h. The products can be irradiated in a single direction, two-pass, two-sided method. (auth.). 11 refs.; 4 figs.; 2 tabs

  20. Evaluation of skyshine dose due to gamma-rays from a cobalt-60 irradiation facility

    International Nuclear Information System (INIS)

    Kanazawa, Tamotsu; Okamoto, Shinichi; Ohnishi, Tokuhiro; Tsujii, Yukio

    1991-01-01

    We attempted to evaluate skyshine dose due to gamma-rays from a cobalt-60 irradiation facility. As the first step, the results of measurements and calculations were compared of the skyshine dose due to gamma-rays from the cobalt-60 source of 1.45 PBq set in the No.4 irradiation room of our laboratory. Distances of measuring points from the cobalt source were in the range from 17 m to about 100 m in the site of our office. Calculation was carried out with simplified single scattering method. The calculated values of the skyshine dose were higher than the measured values. For more precise evaluation of the skyshine dose, the following factors are to be considered; the dose rate distribution on the roof above the source and the attenuation of gamma-rays by air. (author)

  1. Cobalt-60 simulation of LOCA [loss of coolant accident] radiation effects

    International Nuclear Information System (INIS)

    Buckalew, W.H.

    1989-07-01

    The consequences of simulating nuclear reactor loss of coolant accident (LOCA) radiation effects with Cobalt-60 gamma ray irradiators have been investigated. Based on radiation induced damage in polymer base materials, it was demonstrated that electron/photon induced radiation damage could be related on the basis of average absorbed radiation dose. This result was used to estimate the relative effectiveness of the mixed beta/gamma LOCA and Cobalt-60 radiation environments to damage both bare and jacketed polymer base electrical insulation materials. From the results obtained, it is concluded that present simulation techniques are a conservative method for simulating LOCA radiation effects and that the practices have probably substantially overstressed both bare and jacketed materials during qualification testing. 9 refs., 8 figs., 5 tabs

  2. Contamination of steel produced in the Czech Republic by cobalt 60

    International Nuclear Information System (INIS)

    Malatova, I.; Foltanova, S.; Rulik, P.

    1999-01-01

    In recent years, the metal recycling industry has become aware of the presence of radioactive materials in scrap metal. While the problem has historical roots dating to the earliest days of the use of radium, the use of radioactive materials in industrial devices, coupled with incorrect disposal of those devices led to many cases where radioactive sources were unintentionally smelted in the course of recycling. A survey was made of the steel contamination produced during file years 1993 to 1996 in nine steel producing plants. Altogether 721 steel samples were measured by semiconductor gamma spectrometry. In 62% of the samples, no cobalt 60 activity was detected, i.e. the activity was below the minimum significant activity. In 95.5% of the samples, activity concentration of cobalt 60 was below 10 Bq/kg and in 3.4% of the samples, the activity concentration was between 100 and 1000 Bq/kg. The samples were collected according to a scheme which ensured a random choice. In addition, eight samples collected in plants where file investigation was performed were measured, following the melting of contaminated scrap. These samples had activity concentration of cobalt 60 greater than 1000 Bq/kg. (author)

  3. Effect of different ionizing radiation doses and dose rates, using Cobalt-60 and electrons beam sources, on the staphylococcal enterotoxin inoculated in mechanically deboned chicken meat

    Energy Technology Data Exchange (ETDEWEB)

    Pomarico Neto, Walter; Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Fukuma, Henrique Takuji, E-mail: pbrito@cnen.gov.br, E-mail: hazevedo@cnen.gov.br, E-mail: cvroque@cnen.gov.br, E-mail: htfukuma@cnen.gov.br [Brazilian Nuclear Energy Commission (LAPOC/CNEN), Pocos de Caldas, MG (Brazil); Kodama, Yasko, E-mail: ykodama@ipen.br [Nuclear and Energy Research Institute (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Miya, Norma Terugo Nago; Pereira, Jose Luiz, E-mail: miya@fea.unicamp.br, E-mail: pereira@fea.unicamp.br [Campinas State University (UNICAMP), SP (Brazil). Dept. of Food Sciences

    2011-07-01

    The purpose of food irradiation is the destruction of present pathogenic microorganisms and the increase of shelf life of foods. To achieve this process, the source of cobalt-60 and the electron accelerator can be used. The mechanically deboned chicken meat (MDCM) is used for the production of traditional meat products, and it may come to present pathogenic microorganisms such as staphylococcus aureus, a bacterium that produces enterotoxin, which causes food poisoning. The objective of this study is to analyze the effect of ionizing irradiation with different doses and dose rates, deriving from different radiation sources, on staphylococcal enterotoxin type B (SEB) in the MDCM. 50 g samples of MDCM were prepared in a batch of 6 kg of MDCM. The samples were contaminated, with the exception of the control, with SEB in amounts of about 100 ng. Then they were conditioned in a transparent bag made of low density polyethylene, frozen at -18{+-}1 deg C overnight and irradiated in these conditions with doses of 0.0 kGy (control), 1.5 kGy and 3.0 kGy, and with three different dose rates, both in the Cobalt-60 and the electron accelerator. The experiments were conducted in quintuplicate. The SEB extraction from the MDCM was performed according to the protocol recommended by the manufacturer of the kit VIDAS Staph Enterotoxin II (bioMerrieux). The principle of mass balance was used to determine the actual amount of SEB removed by irradiation. The treatment that presented the best results was the one with a dose of 1.5 kGy, high dose rate of the electron accelerator. (author)

  4. Effect of different ionizing radiation doses and dose rates, using Cobalt-60 and electrons beam sources, on the staphylococcal enterotoxin inoculated in mechanically deboned chicken meat

    International Nuclear Information System (INIS)

    Pomarico Neto, Walter; Brito, Poliana de Paula; Azevedo, Heliana de; Roque, Claudio Vitor; Fukuma, Henrique Takuji; Kodama, Yasko; Miya, Norma Terugo Nago; Pereira, Jose Luiz

    2011-01-01

    The purpose of food irradiation is the destruction of present pathogenic microorganisms and the increase of shelf life of foods. To achieve this process, the source of cobalt-60 and the electron accelerator can be used. The mechanically deboned chicken meat (MDCM) is used for the production of traditional meat products, and it may come to present pathogenic microorganisms such as staphylococcus aureus, a bacterium that produces enterotoxin, which causes food poisoning. The objective of this study is to analyze the effect of ionizing irradiation with different doses and dose rates, deriving from different radiation sources, on staphylococcal enterotoxin type B (SEB) in the MDCM. 50 g samples of MDCM were prepared in a batch of 6 kg of MDCM. The samples were contaminated, with the exception of the control, with SEB in amounts of about 100 ng. Then they were conditioned in a transparent bag made of low density polyethylene, frozen at -18±1 deg C overnight and irradiated in these conditions with doses of 0.0 kGy (control), 1.5 kGy and 3.0 kGy, and with three different dose rates, both in the Cobalt-60 and the electron accelerator. The experiments were conducted in quintuplicate. The SEB extraction from the MDCM was performed according to the protocol recommended by the manufacturer of the kit VIDAS Staph Enterotoxin II (bioMerrieux). The principle of mass balance was used to determine the actual amount of SEB removed by irradiation. The treatment that presented the best results was the one with a dose of 1.5 kGy, high dose rate of the electron accelerator. (author)

  5. A Vision Controlled Robot to Detect and Collect Fallen Hot Cobalt60 Capsules inside Wet Storage Pool of Cobalt60 Irradiators

    International Nuclear Information System (INIS)

    Solyman, A.E.M.

    2015-01-01

    In a typical irradiator that use radioactive cobalt-60 capsules source is one of the peaceful uses of atomic energy, it originated strategy in terms of its importance in the sterilization of medical products and food processing from bacteria and fungi before being exported. However, there are several well-known problems related to the fall of the cobalt-60 capsules inside the wet storage pool as a result of manufacturing defects, defects welds or a problem occurs in the vertical movement of the radioactive source rack. Therefore it is necessary to study this problem and solve it in a scientific way so as to keep the human as much as possible from radiation exposure, according to the principles of radiation protection and safety issued by the International Atomic Energy Agency. The present work considers the possibility to use a vision based control arm robot to collect fallen hot cobalt-60 capsules inside wet storage pool. A 5-DOF arm robot is designed and vision algorithms are established to pick the fallen capsule on the bottom surface of the storage pool, read the information printed on its edge (cap) and move it to a safe storage place. Two object detection approaches are studied; RGB-based filter and background subtraction technique. Vision algorithms and camera calibration are done using MATLAB/SIMULINK program. Robot arm forward and inverse kinematics are developed and programmed using an embedded micro controller system. Experiments show the validity of the proposed system and prove its success. The collecting process will be done without interference of operators, so radiation safety will be increased. The results showed camera calibration equations accuracy. And also the presence of vibrations in the hands of the movement of the robot and thus were seized motor rotation speed to 10 degrees per second to avoid these vibrations.This scientific application keeps the operators as much as possible from radiation exposure so it leads to increase radiation

  6. Aspect of sucrose and its monomers from sugarcane juice submitted to different doses of cobalt-60 irradiation

    International Nuclear Information System (INIS)

    Lima, Roberta B.; Rela, Paulo; Arthur, Valter; Souza, Juliana Ap.; Prezotto, Mariane P.; Baptista, Antonio S.; Aguiar, Claudio L.

    2011-01-01

    /h by Cobalt-60, to those doses analyzed, were not sufficient to modify the sugars profiles found in sugarcane juice, indicating viability to use of gamma irradiation technology on sugar and energy industry, either as an alternative to the clarification (for pigment degradation) in crystal sugar or sterilization process of sugarcane juice. (author)

  7. Aspect of sucrose and its monomers from sugarcane juice submitted to different doses of cobalt-60 irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Roberta B.; Rela, Paulo [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Arthur, Valter, E-mail: arthur@cena.usp.br [Centro de Energia Nuclear da Agricultura (CENA/USP), Piracicaba, SP (Brazil). Dept. de Radiobiologia e Ambiente; Souza, Juliana Ap.; Prezotto, Mariane P.; Baptista, Antonio S.; Aguiar, Claudio L., E-mail: claguiar@esalq.usp.br [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP, (Brazil). Dept. de Agroindustria, Alimentos e Nutricao

    2011-07-01

    emitted to dose rate of 3.88 KGy/h by Cobalt-60, to those doses analyzed, were not sufficient to modify the sugars profiles found in sugarcane juice, indicating viability to use of gamma irradiation technology on sugar and energy industry, either as an alternative to the clarification (for pigment degradation) in crystal sugar or sterilization process of sugarcane juice. (author)

  8. Hematological changes in sheep inoculated with natural and Cobalt60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768

    Directory of Open Access Journals (Sweden)

    D. P. Netto

    2004-01-01

    Full Text Available Natural (NV and Cobalto60-irradiated (IrV Crotalus durissus terrificus venom were used to evaluate serum production capacity of sheep and possible hematological and biochemical effects. Freeze-dried venom aliquots were diluted in acidified saline solution (NaCl 150 mM, pH 3.0 and irradiated by a Cobalt 60 source at a dose of 5.54 x 102 Gy/h and a concentration of 2.000 Gy. Twelve sheep were divided into two groups of six animals. One group received irradiated venom (IrV and the other natural venom (NV. Three antigen doses (venom were administered at monthly intervals. Blood samples were collected weekly for analysis of serum neutralization potency and capacity, complete blood count (CBC, total plasma protein, fibrinogen, albumin, and globulin. At the end of the experiment, the animals were challenged with a LD50 for sheep and showed no signs of envenoming. The two groups did not present clinical alterations. Results of the total leukocyte count did not present interaction or time factor effect for both groups, but there was a different action between them, with the NV group presenting more cells than the IrV group. The leukocyte increase to 13,000/ml indicates that slight leukocytosis occurred in the week after the first inoculation in the NV group. There was no statistically significant difference between groups in the absolute count of segmented neutrophils, eosinophils, and lymphocytes but there were statistically significant oscillations in values at the different collecting times. The NV group presented an increase in the absolute neutrophil count after the first inoculation that persisted for 5 weeks. In the IrV group, the increase in neutrophils occurred only in the first week returning to normal in the following weeks. The alterations in the neutrophil count are indicative of systemic inflammatory response related to cytokine release; response was more marked in the NV group, showing its greater toxicity.

  9. Direct uptake of cobalt 60 by the carp (Cyprinus carpio L.) following experimental chronic or cyclical contamination of water

    International Nuclear Information System (INIS)

    Amiard-Triquet, C.; Foulquier, L.

    1978-01-01

    Irrespective of the nature of experimental cobalt 60 contamination (chronic or cyclical), the activity level in the carp was highest after 32 or 35 days when the concentration factor reached 3. An analysis of cobalt 60 distribution shows preferential uptake by the kidneys. It therefore seems unlikely that the discharge rate of effluents from the nuclear industry and the resulting variations of radioactivity levels in the water significantly modify the impact of contamination on aquatic organisms [fr

  10. Transport of radioactive source of cobalt-60 for the steel industry

    International Nuclear Information System (INIS)

    Santos, Paulo de Oliveira

    2009-01-01

    Radioactive materials are used in the fields of medicine, industry, research and nuclear power production. The use of radioactive material may involve transportation and this implies in the application of safety measures to the workers, public and the environment. Many types of radioactive material are produced all over the world and some modes of transport are involved. The IAEA regulations are based on the philosophy that radioactive material being transported should be adequately packaged to provide protection against the hazards of the material under all conditions of transport. Some Brazilian steel industries control the levels of liquid steel in continuous casting systems by means of sealed sources of cobalt-60. The Center for Development of Nuclear Technology-CDNT produces several of these sources to meet these industries and these sources must be transported in packages designed and tested as requirements of the rules of carriage of radioactive materials. For the transportation of seven sources of cobalt-60 with total activity of 1 GBq since CDNT to the applicant industries was designed, built and tested a Type A package. The thickness of the shield to meet the surface dose rate and the index of transport was calculated by MCNP (Monte Carlo N-Particle Transport Code-Version 5) and practical values were compatible. The sealed sources of cobalt-60 were tested as to leak through the tightness test conducted according to ISO 9978:1992 (E) and the tests to demonstrate the capability of resistance of packaged under normal conditions of transport were made on the facilities of CDNT. (author)

  11. Field and laboratory evaluation of the mobility of cobalt-60/EDTA in an arid environment

    International Nuclear Information System (INIS)

    Jones, T.L.; Gee, G.W.; Swanson, J.L.; Kirkham, R.R.

    1983-02-01

    The ability of the organic complexant EDTA to enhance the mobility of cobalt-60 was investigated in both laboratory and field experiments. Laboratory tests consisted of short term (approximately 7 day) column and batch adsorption tests using soil from the Hanford site as well as long term (approximately 70 day) batch tests with Hanford soil and soils from Oak Ridge and Savannah River. In addition, two large scale tracer tests were conducted using Hanford soil. One used a large (1.6 m) laboratory column, spiked with cobalt-60/EDTA and the other was a field test conducted in an 8 m deep lysimeter. Enhanced mobility decreased sorption were observed in both column and batch tests when the cobalt-60/EDTA solutions contacted Hanford and Oak Ridge soil for only a few days. When long contact times were allowed (months) the Hanford soil showed large increases in sorption with time. The low sorption exhibited initially by the Oak Ridge soil increased slightly over time, however, the high sorption observed with the Savannah River soil remained constant with time. The reduced mobility, with time, observed in Hanford soils was confirmed in both the large scale laboratory and breaking down when contacted with Hanford and Savannah River soil and to a lesser extent, the Oak Ridge soil. It is not known at this time why the complex is breaking down or why the kinetics are different among the soils tested. The implication to waste management is that the potential for transport of cobalt by EDTA complexation may not be as serious as once thought

  12. Analysis and development of methods of correcting for heterogeneities to cobalt-60: computing application

    International Nuclear Information System (INIS)

    Kappas, K.

    1982-11-01

    The purpose of this work is the analysis of the influence of inhomogeneities of the human body on the determination of the dose in Cobalt-60 radiation therapy. The first part is dedicated to the physical characteristics of inhomogeneities and to the conventional methods of correction. New methods of correction are proposed based on the analysis of the scatter. This analysis allows to take account, with a greater accuracy of their physical characteristics and of the corresponding modifications of the dose: ''the differential TAR method'' and ''the Beam Substraction Method''. The second part is dedicated to the computer implementation of the second method of correction for routine application in hospital [fr

  13. Chronic cardiac arrhythmias produced by focused cobalt-60 gamma irradiation of the canine atria

    International Nuclear Information System (INIS)

    Dick, H.L.H.; Saylor, C.B.; Reeves, M.M.; Davies, M.J.

    1979-01-01

    Cardiac arrhythmias following exposure of the human heart to ionizing radiation have been reported. Earlier experiments involving irradiation of the hearts of various animals failed to consistently produce similar arrhythmias. In the present work, cobalt-60 irradiation was focused on the interatrial septum of the hearts of 12 dogs. Ten animals developed arrhythmias: These were repetive junctional and atrial tachycardias, repetitive atrial fibrillation, and type one, second-degree atrial ventricular block. The duration varied from 1 to 52 days, with onsets varying from 48 to 146 days postirradiation

  14. A Measurement and Analysis of Buildup Region Dose for Open Field Photon Beams (Cobalt-60 through 24 MV)

    International Nuclear Information System (INIS)

    McCullough, Edwin C.

    2015-01-01

    The central axis depth dose in the build-up region (surface to d_m_a_x) of single open field photon beams (cobalt-60 through 24 MV) has been measured utilizing parallel plate and extrapolation chamber methodology. These data were used to derive, for a prescription dose of 100 cGy, values of surface dose, the maximum value of dose along the central axis (D_m_a_x) and the depth (nearest the surface) at which 90% of the prescription dose occurs (d_9_0). For both single and parallel opposed pair (POP) open field configurations, data are presented at field sizes of 5 × 5, 15 × 15 and 25 × 25 cm"2 for prescription depths of 10, 15 and 20 cm (midplane for POP). For the treatment machines, field sizes, and prescription depths studied, it is possible to conclude that: for single open field irradiation, surface dose values (as a percentage of the prescription dose) can be either low (<10%) or comparable to the prescription dose itself; for POP open fields, surface dose values are relatively independent of photon energy and midplane depth, and range between 30% and 70% of prescription dose, being principally dependent on field size; the depth of the initial 90 cGy point for a prescription dose of 100 cGy, d_9_0, was larger for POP fields. For either single or POP open field treatments, d_9_0 was always less than 22 mm, while for 6 MV or less, values of d_9_0 were less than 4 mm; D_m_a_x values can be very large (e.g., above 300 cGy) for certain treatment situations and are reduced significantly for POP treatments; for open field POP treatments, the percent reduction in D_m_a_x with each increment in beam energy above 10 MV is reduced over that seen at 10 MV or less and, possibly, this further reduction may be clinically insignificant; for open field POP treatments, changes in surface dose, d_9_0 and D_m_a_x with beam energy above 10 MV do not suggest, with regard to these specific build-up curve parameters, any obvious advantage for treatment with beam energies greater

  15. Effect of cobalt-60 irradiation on the developing tooth germ of rat

    Energy Technology Data Exchange (ETDEWEB)

    You, Dong Soo; Lee, Ki Sik [Department of Dental Radiology, Graduate School, Seoul National University, Seoul (Korea, Republic of)

    1976-11-15

    The author observed the effects of the cobalt-60 irradiation on the amelogenesis and dentinogenesis of the albino rat fetuses by means of histological and histochemical methods. Female in oestrus were mated overnight and examined the next morning for evidence of copulation. The lower left abdomen of mothers were exposed to cobalt-60 irradiation on the 10th day of gestation, 100R 200R and 300R respectively. The fetuses were removed from the mothers on the 18th day of gestation. The employed histochemical methods were PAS reaction, colloidal iron reaction, aldehyde fuchsin stain, -amino acid reaction, -SH radical reaction, and methyl green pyronin stain. The results were as follows; 1. The group irradiated by 100R made no histological differences in comparison with the control group. 2. Increasing the irradiation to 200R, abnormal dentin formation occurred, and resulted in enamel hypoplasia, atrophy, and necrosis of odontoblasts. In dentinal papilla, the dilation and the degeneration of the blood vessels, excessive reticular atrophy, and osteodentin were revealed. 3. With the more irradiation (200R-300R), the positive material of PAS, {alpha}-amino acid and aldehyde fuchsin tended to decrease in the ameloblast and in the odontoblast. No significant changes appeared in DNA, the stainability of methylgreen pyronin.

  16. Model for cobalt 60/58 deposition on primary coolant piping in a boiling water reactor

    International Nuclear Information System (INIS)

    Dehollander, W.R.

    1979-01-01

    A first principles model for deposition of radioactive metals into the corrosion films of primary coolant piping is proposed. It is shown that the predominant mechanism is the inclusion of the radioactive species such as Cobalt 60 into the spinel structure of the corrosion film during the act of active corrosion. This deposition can occupy only a defined fraction of the available plus 2 valence sites of the spinel. For cobalt ions, this ratio is roughly 4.6 x 10 -3 of the total iron sites. Since no distinction is made between Cobalt 60, Cobalt 58, and Cobalt 59 in this process, the radioactivity associated with this inclusion is a function of the ratio of the radioactive species to the nonradioactive species in the water causing the corrosion of the pipe metal. The other controlling parameter is the corrosion rate of the pipe material. This can be a function of time, for example, and it shown that freshly descaled metal when exposed to the cobalt containing water can incorporate as much as 10 x 10 -3 cobalt ions per iron atom in the initial corrosion period. This has implications for the problem of decontaminating nuclear reactor piping. Equations and selected observations are presented without reference to any specifically identified reactor or utility, so as to protect any proprietary interest

  17. Computer generation of cobalt-60 single beam dose distribution using an analytical beam model

    International Nuclear Information System (INIS)

    Jayaraman, S.

    1981-01-01

    A beam dose calculation model based on evaluation of tissue air ratios (TAR) and scatter air ratios (SAR) for cobalt-60 beams of rectangular cross section has been developed. Off-central axis fall-off of primary radiation intensity is derived by an empirical formulation involving an arctangent function with the slope of the geometrical penumbra acting as an essential constant. Central axis TAR and SAR values are assessed by semi-empirical polynomial expressions employing the two sides of the rectangular field as the bariables. The model utilises a minimum number of parametric constants and is useful for computer generation of isodose curves. The model is capable of accounting for situations where wedge filters or split field shielding blocks, are encountered. Further it could be widely applied with minor modifications to several makes of the currently available cobalt-60 units. The paper explains the model and shows examples of the results obtained in comparison with the corresponding experimentally determined dose distributions. (orig.) [de

  18. Determination of cobalt-60 in seawater by solvent extraction with pyrrolidinedithiocarbamic acid

    International Nuclear Information System (INIS)

    Tseng, C.L.; Lo, J.M.

    1978-01-01

    Cobalt-60 was extracted from a large volume of seawater and concentrated in a small volume of organic solution of pyrrolidinedithiocarbamic acid (HPDC) in chloroform. All foreign nuclides in the organic phase were stripped completely with 12N HCl and 2N HNO 3 successively. By this procedure, a chemically pure Co-60 chelate, 60 Co(PDC) 3 , in chloroform was obtained. The recovery of Co-60 activity was found to average 99%. Cobalt-60 in seawater can thus be simply, rapidly and accurately determined by direct NaI(Tl) scintillation counting. The time for a single analysis, for example, exclusive of the counting operation, is about 40 min. The effects of various foreign nuclides on the extraction of Co-60 were examined by the use of 42 radiotracers and the results are tabulated. The nuclides Ag + , Mn 2+ , Ni 2+ , Cu 2+ , Zn 2+ , Cd 2+ , Pb 2+ , Hg 2+ , Fe 3+ , Ga 3+ , In 3+ , As 3+ , Sn 4+ , and Cr 6+ were extracted almost completely into chloroform with cobalt as the pyrrolidinedithiocarbamates. The extraction yield of Sb 3+ was close to 90%. Appreciable fractions of Cs + , Ba 2+ , Cr 3+ , Zr 4+ and Np 5+ were also found in the organic phase. (T.I.)

  19. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    International Nuclear Information System (INIS)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B.; Sakuraba, Roberto K.; Goncalves, Vinicius D.

    2011-01-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  20. Preliminary dosimetric methodology for a new cobalt-60 irradiator for radioinduced necrosis

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Mosca, Rodrigo C.; Zeituni, Carlos A.; Rostelato, Maria Elisa C.M.; Mathor, Monica B., E-mail: esmoura@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Sakuraba, Roberto K.; Goncalves, Vinicius D. [Hospital Israelita Albert Einstein (HIAE), Sao Paulo, SP (Brazil)

    2011-07-01

    The use of ionizing radiation in medical procedures, as radiotherapy, is a well-established clinical process and it has been used for several decades with good clinical results and continuous technology development for treatment optimization. On the contrary, some injuries such as necrosis, may occur with patients, due to wrong administration of the absorbed dose or with expected side effects. To evaluate how these injuries could be investigated and how they can be treated, a new Cobalto-60 irradiator was developed to induce radionecrosis in mice. This irradiator is composed by a cylindrical size and it was set up with eleven Cobalt-60 sources aligned in the surface of a cylindrical lead. This alignment guarantees a small dose focal area in a longitudinal table, with proper frames for positioning mice precisely during the irradiations period. The dosimetric procedure will measure the absorbed dose in the dose focal area, delimited the area of irradiation with penumbra regions (gradients absorbed dose profiles) and others anatomical regions of the mice with high radiosensitivity. Possible dosimetric procedures and related devices will be present in this work,. The obtained dosimetric data will be applied to ensure the accurate period of radiation of a given position. This preliminary study assures that the fundamental dosimetric process of this new Cobalt-60 irradiator and it predicates that dosimetric processes area feasible to be conducted. (author)

  1. Evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Sang Keun; Kim, Wook; Park, Yong Sung; Kang, Joo Hyun; Lee, Yong Jin [Korea Institute of Radiological and Medical Sciences, KIRAMS, Seoul (Korea, Republic of); Cho, Doo Wan; Lee, Hong Soo; Han, Su Cheol [Jeonbuk Department of Inhalation Research, Korea Institute of toxicology, KRICT, Jeongeup (Korea, Republic of)

    2016-12-15

    These absorbed dose can calculated using the Monte Carlo transport code MCNP (Monte Carlo N-particle transport code). Internal radiotherapy absorbed dose was calculated using conventional software, such as OLINDA/EXM or Monte Carlo simulation. However, the OLINDA/EXM does not calculate individual absorbed dose and non-standard organ, such as tumor. While the Monte Carlo simulation can calculated non-standard organ and specific absorbed dose using individual CT image. External radiotherapy, absorbed dose can calculated by specific absorbed energy in specific organs using Monte Carlo simulation. The specific absorbed energy in each organ was difference between species or even if the same species. Since they have difference organ sizes, position, and density of organs. The aim of this study was to individually evaluated cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. We evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. The absorbed energy in each organ compared with mouse heart was 54.6 fold higher than monkey absorbed energy in heart. Likewise lung was 88.4, liver was 16.0, urinary bladder was 29.4 fold higher than monkey. It means that the distance of each organs and organ mass was effects of the absorbed energy. This result may help to can calculated absorbed dose and more accuracy plan for external radiation beam therapy and internal radiotherapy.

  2. Evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation

    International Nuclear Information System (INIS)

    Woo, Sang Keun; Kim, Wook; Park, Yong Sung; Kang, Joo Hyun; Lee, Yong Jin; Cho, Doo Wan; Lee, Hong Soo; Han, Su Cheol

    2016-01-01

    These absorbed dose can calculated using the Monte Carlo transport code MCNP (Monte Carlo N-particle transport code). Internal radiotherapy absorbed dose was calculated using conventional software, such as OLINDA/EXM or Monte Carlo simulation. However, the OLINDA/EXM does not calculate individual absorbed dose and non-standard organ, such as tumor. While the Monte Carlo simulation can calculated non-standard organ and specific absorbed dose using individual CT image. External radiotherapy, absorbed dose can calculated by specific absorbed energy in specific organs using Monte Carlo simulation. The specific absorbed energy in each organ was difference between species or even if the same species. Since they have difference organ sizes, position, and density of organs. The aim of this study was to individually evaluated cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. We evaluation of cobalt-60 energy deposit in mouse and monkey using Monte Carlo simulation. The absorbed energy in each organ compared with mouse heart was 54.6 fold higher than monkey absorbed energy in heart. Likewise lung was 88.4, liver was 16.0, urinary bladder was 29.4 fold higher than monkey. It means that the distance of each organs and organ mass was effects of the absorbed energy. This result may help to can calculated absorbed dose and more accuracy plan for external radiation beam therapy and internal radiotherapy.

  3. Effect of cobalt-60 irradiation on the developing tooth germ of rat

    International Nuclear Information System (INIS)

    You, Dong Soo; Lee, Ki Sik

    1976-01-01

    The author observed the effects of the cobalt-60 irradiation on the amelogenesis and dentinogenesis of the albino rat fetuses by means of histological and histochemical methods. Female in oestrus were mated overnight and examined the next morning for evidence of copulation. The lower left abdomen of mothers were exposed to cobalt-60 irradiation on the 10th day of gestation, 100R 200R and 300R respectively. The fetuses were removed from the mothers on the 18th day of gestation. The employed histochemical methods were PAS reaction, colloidal iron reaction, aldehyde fuchsin stain, -amino acid reaction, -SH radical reaction, and methyl green pyronin stain. The results were as follows; 1. The group irradiated by 100R made no histological differences in comparison with the control group. 2. Increasing the irradiation to 200R, abnormal dentin formation occurred, and resulted in enamel hypoplasia, atrophy, and necrosis of odontoblasts. In dentinal papilla, the dilation and the degeneration of the blood vessels, excessive reticular atrophy, and osteodentin were revealed. 3. With the more irradiation (200R-300R), the positive material of PAS, α-amino acid and aldehyde fuchsin tended to decrease in the ameloblast and in the odontoblast. No significant changes appeared in DNA, the stainability of methylgreen pyronin.

  4. Analysis of Gafchromic EBT3 film calibration irradiated with gamma rays from different systems: Gamma Knife and Cobalt-60 unit.

    Science.gov (United States)

    Najafi, Mohsen; Geraily, Ghazale; Shirazi, Alireza; Esfahani, Mahbod; Teimouri, Javad

    2017-01-01

    In recent years, Gafchromic films are used as an advanced instrument for dosimetry systems. The EBT3 films are a new generation of Gafchromic films. Our main interest is to compare the response of the EBT3 films exposed to gamma rays provided by the Theratron 780C as a conventional radiotherapy system and the Leksell Gamma Knife as a stereotactic radiotherapy system (SRS). Both systems use Cobalt-60 sources, thus using the same energy. However, other factors such as source-to-axis distance, number of sources, dose rate, direction of irradiation, shape of phantom, the field shape of radiation, and different scatter contribution may influence the calibration curve. Calibration curves for the 2 systems were measured and plotted for doses ranging from 0 to 40 Gy at the red and green channels. The best fitting curve was obtained with the Levenberg-Marquardt algorithm. Also, the component of dose uncertainty was obtained for any calibration curve. With the best fitting curve for the EBT3 films, we can use the calibration curve to measure the absolute dose in radiation therapy. Although there is a small deviation between the 2 curves, the p-value at any channel shows no significant difference between the 2 calibration curves. Therefore, the calibration curve for each system can be the same because of minor differences. The results show that with the best fitting curve from measured data, while considering the measurement uncertainties related to them, the EBT3 calibration curve can be used to measure the unknown dose both in SRS and in conventional radiotherapy. Copyright © 2017. Published by Elsevier Inc.

  5. Semi-empirical equivalent field method for dose determination in midline block fields for cobalt - 60 beam

    International Nuclear Information System (INIS)

    Tagoe, S.N.A.; Nani, E.K.; Yarney, J.; Edusa, C.; Quayson-Sackey, K.; Nyamadi, K.M.; Sasu, E.

    2012-01-01

    For teletherapy treatment time calculations, midline block fields are resolved into two fields, but neglecting scattering from other fields, the effective equivalent square field size of the midline block is assumed to the resultant field. Such approach is underestimation, and may be detrimental in achieving the recommended uncertainty of ± 5 % for patient's radiation dose delivery. By comparison, the deviations of effective equivalent square field sizes by calculations and experiments were within 13.2 % for cobalt 60 beams of GWGP80 cobalt 60 teletherapy. Therefore, a modified method incorporating the scatter contributions was adopted to estimate the effective equivalent square field size for midline block field. The measured outputs of radiation beams with the block were compared with outputs of square fields without the blocks (only the block tray) at depths of 5 and 10 cm for the teletherapy machine employing isocentric technique, and the accuracy was within ± 3 % for the cobalt 60 beams. (au)

  6. Cobalt Blues The Story of Leonard Grimmett, the Man Behind the First Cobalt-60 Unit in the United States

    CERN Document Server

    Almond, Peter R

    2013-01-01

    For the latter half of the 20th century, cobalt-60 units were the mainstay of radiation treatments for cancer. Cobalt Blues describes the development of the first cobalt-60 unit in the United States and the man behind it, Leonard Grimmett. Conceptually conceived before World War II, it only became possible because of the development of nuclear reactors during the war. Although Grimmett conceived of and published his ideas first, the Canadians built the first units because of the capability of their reactor to produce more suitable cobalt-60 sources. This book tells the story of how Grimmett and others came together at the time that the U S Atomic Energy Agency was pushing the use of radioactivity in medicine. Due to his sudden death, very little information about Grimmett was known until recently, when various documents have come to light, allowing the full story to be told.

  7. Effect of cobalt-60 gamma-ray irradiation on beans (Phaseolus vulgaris L.) of huasteco variety

    International Nuclear Information System (INIS)

    Navarro A, W.

    1984-01-01

    Bean seeds, Huasteco variety, were irradiated at 10, 20, 30 and 40 kR in a cobalt-60 gamma-ray source. Non-irradiated seeds were used as control. Irradiated and non-irradiated seeds were planted under greenhouse conditions using a random design and a population of 200 plants per treatment for both first and second generations (M 1 and M 2 ). The characters studied were; germination, survival, morphological changes of leaves and stem, change in seed coat colour, flowering, height, stem diameter, number of internodes, number of pods and number of seeds per pod. General plant behaviour was also observed to detect changes on a genic or chromosomic level. (M.A.C.) [pt

  8. High accumulation of cobalt-60 by the particular organ or part of some species in mollusca

    International Nuclear Information System (INIS)

    Yoshida, Katsuhiko

    1981-01-01

    A large amounts of samples in marine Cephalopoda and Tridacna were sampled in north west pacific ocean, near Japan. The samples were separated into organs or parts for determination of Co-60 concentration. A peculiar accumulation of Co-60 by the branchial heart of Octopus was also recognized in field condition, but it had become apparent that branchial heart of squid had not same ability. Liver of Cephalopoda had the ability to highly accumulate the Co-60 and specific activity of squid was one order highter than Octopus. The concentration of Cobalt-60 in visceral muss kidney of Tridacna maxima lineally increased with increasing shell length but that in other soft parts was kept constant. After examination of the other papers it was assumed that Co-60 highly accumulated in these organs was transfered by the food chain. (author)

  9. Exposure buildup factors for a cobalt-60 point isotropic source for single and two layer slabs

    International Nuclear Information System (INIS)

    Chakarova, R.

    1992-01-01

    Exposure buildup factors for point isotropic cobalt-60 sources are calculated by the Monte Carlo method with statistical errors ranging from 1.5 to 7% for 1-5 mean free paths (mfp) thick water and iron single slabs and for 1 and 2 mfp iron layers followed by water layers 1-5 mfp thick. The computations take into account Compton scattering. The Monte Carlo data for single slab geometries are approximated by Geometric Progression formula. Kalos's formula using the calculated single slab buildup factors may be applied to reproduce the data for two-layered slabs. The presented results and discussion may help when choosing the manner in which the radiation field gamma irradiation units will be described. (author)

  10. Dose measurements for characterization of a semi-industrial cobalt-60 gamma-irradiation facility

    International Nuclear Information System (INIS)

    Farah, K.; Jerbi, T.; Kuntz, F.; Kovacs, A.

    2006-01-01

    Cobalt-60 irradiation facility has been put into operation at the National Centre of Nuclear Sciences and Technology, Sidi-thabet, Tunisia. Its technical specifications were controlled by dosimetry commissioning experiments and compared to the data specified by the plant manufacturer. Installation qualification has been carried out to measure absorbed dose distribution in the irradiation cell and products. Two dosimeter systems were used for measurements: Red and Amber Perspex and Cellulose Triacetate (CTA). The regions of minimum and maximum absorbed dose within a homogeneous dummy product (sawdust) with a bulk density of 114kg/m 3 and the dose uniformity ratio were determined. The isodose curves and the three-dimensional views were built using an automatic geostatistical gridding method, the kriging method

  11. Extension of the Commonwealth standard of absorbed dose from cobalt-60 energy to 25 MV

    International Nuclear Information System (INIS)

    Sherlock, S.L.

    1986-01-01

    With the introduction of high energy linear accelerators in hospitals, there is a need for direct measurement of absorbed dose for energies to 25 MV for photons and 20 MeV electrons. The present Australian standard for absorbed dose at cobalt-60 energy is a graphite micro-calorimeter maintained at the AAEC Lucas Heights Research Laboratories. A thorough theoretical analysis of calorimeter operation suggests that computer control and monitoring techniques are appropriate. Solution of Newton's law of cooling for a four-body calorimeter allows development of a computer simulation model. Different temperature control algorithms may then be run and assessed using this model. In particular, the application of a simple differencer is examined. Successful implementation of the calorimeter for energies up to 25 MV could lead to the introduction of an Australian absorbed dose protocol based on calorimetry, therby reducing the uncertainties associated with exposure-based protocols

  12. Calculation support for industrial production of cobalt-60 at Leningrad NPP

    International Nuclear Information System (INIS)

    Artemov, Vladimir; Elshin, Alexander; Ivanov, Alexander; Gorbunov, Evgeny; Ikonnikov, Roman; Pimenov, Alexander

    2008-01-01

    Cobalt-60 is industrially produced at the Leningrad NPP by irradiation of cobalt-59 in special-purpose facilities loaded into the RBMK reactor core (all 4 units). The paper describes calculation methods used to determine the current activity of cobalt in irradiation assemblies for their timely unloading. The described peculiarities of core calculation model account for continuous refueling, overloading of irradiation assemblies and individual thermohydraulics in each channel under variation of reactor power. Fuel burnup in the core is calculated with a time step of about 24 hours. The resulting values for cobalt activity and uncertainties are presented in the paper as well. Deviation of calculated cobalt activity from measured activity is within the experimental accuracy of 10% (at confidence probability of 0.95). (authors)

  13. On the application of a simple model of cobalt-60 beams

    International Nuclear Information System (INIS)

    Gantchew, M.G.

    1979-01-01

    The simple mathematical model of the dose distribution in a phantom irradiated by a single beam of cobalt-60 gamma rays (Wilks, R.J., and Sutcliffe, J.F., 1977, Phys. Med. Biol., vol. 22, 737) requires measurements for each particular field size and diaphragm setting to describe the decrement functions (dose distributions along a straight line perpendicular to the central ray). Measurements made with a Gammatron-3 have shown satisfactory agreement between computed and measured lateral dose distributions for different diaphragm settings if the experimental data was first subjected to additional processing, and Wilks and Sutcliffe's model can therefore be applied to any diaphragm setting using this modification. Field sizes can therefore be entered according to diaphragm indicator reading in dose planning. (U.K.)

  14. Perturbation of cobalt 60 radiation doses by metal objects implanted during oral and maxillofacial surgery

    International Nuclear Information System (INIS)

    Tatcher, M.; Kuten, A.; Helman, J.; Laufer, D.

    1984-01-01

    The influence on cobalt 60 dose distributions of typical metal parts used in oral and maxillofacial surgery was studied. Relative doses were determined by exposing x-ray films in a polystyrene phantom set-up containing samples of vitallium, titanium, and stainless steel. Optical densities were converted to doses with the aid of sensitometric curves. The results show that for normal incidence there is a 25% to 40% increase in dose at the entrance side of the metal and a 20% to 25% decrease in dose at the exit side. The enhancement effect falls off rapidly and becomes negligible at about 1 mm from the interface. The reduction effect decreases more gradually and is still evident at distances of a few centimeters. These dose perturbations should be taken into account in the planning of radiation therapy for patients in whom metal objects have been implanted

  15. Operational Qualification (OQ) Of MINTEC-Sinagama After Cobalt-60 Sources Replenishment

    International Nuclear Information System (INIS)

    Ruzalina Baharin; Hasan Sham; Ahsanulkhaliqin Abdul Wahab

    2014-01-01

    Activity on cobalt-60 sources replenishment at MINTec-Sinagama had been held in May 2014 with total strength of gamma as 440,000 Ci. Therefore, operational qualification (OQ) needs to be done in order to ensure that Sinagama plant is operating well and deliver suitable doses to the customer's products. In this work, three dose mapping exercises were carried out to establish dose distributions and dose reproducibility of plant, which are corresponded to the density of irradiator container (tote) and absorbed dose at normal operation. Dosimeters used were ceric cerous produced by SSDL, Malaysian Nuclear Agency and placed on three planes that represent three-dimensional array. They were located at certain intervals throughout the tote. This paper describes the OQ process and a bit touch on replenishment activity. (author)

  16. The Relation of Design Parameters, Plant Capacity and Processing Costs in Cobalt-60 Sterilization Plants

    International Nuclear Information System (INIS)

    Brown, M.G.

    1967-01-01

    The paper describes the main features of three basic types of cobalt-60 sterilization plants which have been designed to provide a complete range of capacities for radiosterilization of medical products. The smallest plant has a capacity of up to 50 000 cubic feet of medical products a year, the intermediate size plant has a capacity of up to 500 000 cubic feet a year, and the largest plant has a capacity in excess of 1000 000 cubic feet a year. The relations between capital costs, rate of production, efficiency and unit processing costs for each type of plant are discussed. The method of selecting the best type of plant for a particular need will also be outlined. (author)

  17. Formation of amino acids by cobalt-60 irradiation of hydrogen cyanide solutions

    Science.gov (United States)

    Sweeney, M. A.; Toste, A. P.; Ponnamperuma, C.

    1976-01-01

    Experiments were conducted to study the pathway for the prebiotic origin of amino acids from hydrogen cyanide (HCN) under the action of ionizing radiation considered as an effective source of energy on the primitive earth. The irradiations were performed in a cobalt-60 source with a dose rate of 200,000 rad/hr. Seven naturally occurring amino acids are identified among the products formed by the hydrolysis of gamma-irradiated solutions of HCN: glycine, alanine, valine, serine, threonine, aspartic acid, and glutamic acid. The identity of these amino acids is established by gas chromatography and mass spectrometry. Control experiments provided evidence that the amino acids are not the result of contamination.

  18. Concrete Shielding For Radiation Safety And Unexpected Dangerous Inside Cobalt-60 Industrial Irradiator

    International Nuclear Information System (INIS)

    Keshk, A.B.; Aly, R.A.

    2011-01-01

    The study shows a proposed destruction inside one of three cobalt-60 industrial irradiators to determine and reduce the negative results, to improve and modify emergency plan to face terrorism works. The results show the performance of concrete shielding (walls and ceiling) contains the bad effect of dynamic pressures. The explosion forces are prevented to destructive by performance of their concrete shielding, which will contain the most components of devastated systems inside each irradiator after explosion. Shield penetration like electrical cable tunnels, pushers holes, hole with removable plug, product boxes openings, lens opening and ozone duct are affected badly by destruction. Through probability of transporting, some of devastated parts of broken radioactive cobalt- 60 pencils from inside radiation concreter room to outside (surrounded environment) are maintained and causing very danger radiation exposure by gamma rays outside irradiator. A necessity needs to modify emergency plan to prevent any explosive materials to enter inside the main building (irradiation sale) and also discovering any explosive materials which are placed inside the product boxes before passing to inside irradiator. The minimizing radiation exposure (2 mrem/h) inside underground radiation shelters are maintained by reducing radiation dose exerted from a nuclear explosion of 20 kT about 1 km away to a safe value, and calculating the protective factors of radiation main building basements are more than 40 (safety factor) as they are located under ground level, are surrounded by sandy soil and are constructed by concrete. The study shows the proposed basements of the main building maintain success to use as under ground safe radiation shelter (during emergency) with separate safe radiation trace. It begins from the main opening of irradiation sale and leads to underground proposed shelter through modified main stair

  19. Spontaneous carotid-cavernous sinus fistula disappeared following cobalt 60 irradiation. Case report

    Energy Technology Data Exchange (ETDEWEB)

    Satoh, Toru; Yamamoto, Yuji; Asari, Syoji (Matsuyama Shimin Hospital, Ehime (Japan))

    1983-12-01

    The authors reported a case of spontaneous carotid-cavernous sinus fistula fed by meningohypophyseal trunk of the internal carotid artery, that completely disappeared following cobalt 60 irradiation to the region of fistula (27 days; total dose, 4,100 rad). A 65-year-old man was admitted to our hospital on May 25, 1982, with a two-week history of progressive prominence of the left eye, diplopia on left lateral gaze, and continuous intracranial bruit. He first noted redness of the left eye without apparent cause such as head trauma. On admission, slight nonpulsative exophthalmos, periorbital edema, chemosis, and venous congestion of the conjunctiva of the left eye were noted. The pupils were reactive and equal in size, and the left abducent nerve palsy was observed. Fundoscopic examination disclosed to be normal. No bruit was heard over the left orbital region. Left carotid angiography on May 28 demonstrated dural internal carotid-cavernous sinus fistula fed by meningohypophyseal trunk, and drained into superior and inferior ophthalmic veins and basilar venous plexus. Though the patient was treated only conservatively, symptoms became worse to decrease visual acuity. On July 14, we started cobalt 60 irradiation to the region of fistula (27 days; total dose 4,100 rad). Symptoms gradually improved about halfway through irradiation. After completion of irradiation, almost complete improvement of visual and ocular symptoms was observed except the left abducent nerve palsy. Repeated angiography on Aug. 20 revealed complete disappearance of fistula. Three months after treatment, no recurrence of symptoms was observed and the abducent nerve palsy persisted without improvement.

  20. Comparison of skin doses to large fields using tangential beams from cobalt-60 gamma rays and 4-MV x rays

    International Nuclear Information System (INIS)

    Gagnon, W.F.; Peterson, M.D.

    1978-01-01

    Excess radiation to the skin during external beam megavoltage radiation therapy has reportedly caused excessive erythema in patients treated with the Clinac 4 linear accelerator on sloping surfaces, but not for similar treatments with cobalt-60. Doses at the epidermal level were measured under geometries simulating sloping surfaces for a Clinac 4 and an Eldorado 8 cobalt-60 teletherapy machine. For equal doses to the axilla, doses to the epidermal layer were similar. When the tumor dose was calculated for the mediastinum, the dose to the skin in the axillary region was 12% higher for the Clinac 4

  1. Effects of gamma radiation of Cobalt-60 on different phases of the evolutive cycle of pinworm - Tuta absoluta (Meyrich, 1917) (Lepidoptera,Gelechiidae); Efeitos da radiacao gama do Cobalto-60 nas diferentes fases do ciclo evolutivo da traca do tomateiro - Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae)

    Energy Technology Data Exchange (ETDEWEB)

    Groppo, Gerson Antonio

    1996-10-01

    The effects of different gamma radiation (Cobalt-60) doses on different phases of the evolutive cycle of Tuta absoluta (Meyrich, 1917) (Lepidoptera, Gelechiidae) have been studied under laboratory conditions in the laboratory of Entomology of Center for Nuclear Energy in Agriculture (CENA), University of Sao Paulo, Piracicaba, Sao Paulo State, Brazil. For all the treatments with gamma radiation a Cobalt-60 source type Gamma beam-650 was used. The doses utilized ranged from of 0,0 (Control) to 3250 Gy with a dose rate of 1110 Gy/h. The experiment was conducted under controlled conditions at 25{+-} 2 deg C, 70 {+-} 5% of relative humidity and photo period of (12:12). It was verified that the lethal doses were: for eggs - 70 Gy; for larvae - 200 Gy e for pupae - 300 Gy. The sterilizing dose for adults from irradiated larvae was 45 Gy. The sterilizing dose for the crossing of irradiated female with normal males (FI X MN) was 100 Gy and for normal female with irradiated male (FN x MI) was 150 Gy, in the both crosses, doses refer to irradiation of pupae. The sterilizing dose for adults, of both sexes, irradiated and crossed with normal adults, (FI x MN) and (FN x MI, were 150 and 200 Gy, respectively. The average longevity of adults, of both sexes, irradiated and crossed with normal adults was 8,3 days. The immediate lethal dose for adults was 3250 Gy. (author)

  2. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO4: Dy + Ptfe

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin N, J.; Perez P, M.A.; Castillo H, M.; Flores F, F.; Guzman R, L.V.

    1999-01-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO 4 : Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  3. The dosimetry of cobalt-60 γ-ray total body irradiation before bone marrow transplantation

    International Nuclear Information System (INIS)

    Dong Fan; Zhang Guiru

    1989-11-01

    The dosimetric considerations of using conventional cobalt-60 unit total body irradiation (TBI) are presented. By extending the source-to-midplane distance (SMD) to 346 cm, a 92 x 98 cm 2 rectangular field with diagonal dimension 134 cm was obtained. The results from the phantom measurements showed: (1) the effective field corresponding to an average-size patient is 25 x 25 cm 2 , and a method for estimating the effective field of human body is given; (2) the midplane doses are consistently higher than those of surfaces, but the dose ratio of midplane to surface decreases as the body thickness increases, and a significant negative correlation is existed between the dose ratio and thickness, thus a linear regression line is fitted; (3) the anterior-posterior (AP) or AP + bilateral irradiation will yield a more uniform dose distribution in the whole body than the bilateral irradiation; (4) the dose uniformity can apparently be improved by the tissue compensation, for which the technique is described

  4. HAW simulation experiments with cobalt-60 radiation sources in the Asse salt mine

    International Nuclear Information System (INIS)

    Rothfuchs, T.; Wieczorek, K.; Feddersen, H.K.

    1986-01-01

    The report describes the experimental work and the measured data of the joint German-American project for the HAW simulation experiment with cobalt-60 radiation sources in the Asse salt mine, covering the period up to the end of the third quarter 1986. The experiment is intended to yield information on the synergistic effects of heat and ionizing radiation on the salt rock under representative waste repository conditions. The investigations aim at the migration, release, and radiolytic decomposition of the water and gas components in the rock salt, and at the thermally induced strain and deformation processes. In addition, corrosion tests are planned to be made on various container test materials, and analyses of salt rock core samples for assessing the effect of heat and radiation on the rock. The report in hand presents all data obtained during the experiment. The results of the subsequent evaluation and verification studies will be presented in another report, the programme being given in an annex to the report in hand. (orig./RB) [de

  5. Immunological assessment of mice hyperimmunized with native and Cobalt-60-irradiated Bothrops venoms

    International Nuclear Information System (INIS)

    Ferreira Junior, R.S.; Meira, D.A.; Martinez, J.C.

    2005-01-01

    ELISA was used to evaluate, accompany, and compare the humoral immune response of Swiss mice during hyperimmunization with native and Cobalt-60-irradiated ( 60 Co) venoms of Bothrops jararaca, Bothrops jararacussu and Bothrops moojeni. Potency and neutralization were evaluated by in vitro challenges. After hyperimmunization, immunity was observed by in vivo challenge, and the side effects were assessed. The animals immunization with one LD50 of each venom occurred on days 1, 15, 21, 30, and 45, when blood samples were collected; challenges happened on the 60th day. Results showed that ELISA was efficient in evaluating, accompanying and comparing mouse immune response during hyperimmunization. Serum titers produced with natural venom were similar to those produced with irradiated venom. Immunogenic capacity was maintained after 60 Co-irradiation. The sera produced with native venom showed neutralizing potency and capacity similar to those of the sera produced with irradiated venom. All antibodies were able to neutralize five LD50 from these venoms. Clinical alterations were minimum during hyperimmunization with irradiated venom, however, necrosis and death occurred in animals inoculated with native venom. (author)

  6. Research and design of the moving system for the cobalt-60 industrial irradiator

    International Nuclear Information System (INIS)

    Le Minh Tuan; Tran Khac An; Cao Van Chung; Phan Phuoc Thang

    2016-01-01

    On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The nucleus of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1h 20 min and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)

  7. Microbiological Load Of Ethylene Oxide Sterilized Medical Devices And Its Elimination By Cobalt 60 Source

    International Nuclear Information System (INIS)

    Bashir, R.; Afroze, B.; Zulfiqar, H. F.; Saleem, R.; Saleem, F.; Aslam, F.; Naz, S.

    2016-01-01

    Objective: To determine the residing microbial flora of ethylene oxide (EtO) sterilized medical devices and optimization of safe dose of gamma radiation (Cobalt 60 source) for the complete elimination of microbial load. Study Design: Experimental study. Place and Duration of Study: Department of Biotechnology, Lahore College for Women University, Lahore, Pakistan from September 2014 to June 2015. Methodology: Thirty-six samples of EtO sterilized medical devices of same batch of three different companies were collected for this study. Isolation and enumeration of microbes were done by using different selective and differential media. Gram staining and biochemically characterization by API 20 (Bio Merieux, France) kit was done for identification of the microorganisms. The medical devices having high microbial load were sent to Pakistan Radiation Services (PARAS) for gamma irradiations at 3 different selected doses (20 KGy, 25 KGy, and 30 KGy). Result: Different types of Gram positive bacteria (Staphylococcus epidermidis, Staphylococcus aureus and Bacillus subtilis) were isolated from the EtO sterilized samples. Gram negative bacteria and fungi were not detected on these medical devices. Gamma irradiations Result showed that 30 KGy was optimized dose for complete elimination of microbial flora on endotracheal, Nelaton, and tracheostomy tubes. Conclusion: Gamma radiations (Co 60 source) effectively decontaminate the microbial flora on the equipment previously sterilized by the ethylene oxide gas; and 30 KGy is the optimized dose for all these medical devices. (author)

  8. Evaluation of leakage in cobalt-60 unit in National Cancer Institute (NCI) Wad Medani

    International Nuclear Information System (INIS)

    Fadlellah, R. A.

    2013-08-01

    This study has been conducted primarily to evaluate the leakages radiation in cobalt-60 unit in National Cancer Institute Wad Medani, which represent the basic risky factor in this unit for the radio therapists who spend much time during patient set up, also they need to stand near the head of the machine to fix some accessories. The measurements which done using survey meter give normal level of occupational exposure compared with IAEA references except one situation that the radio therapist to be close contact to the head of unit for long time which may increase the received dose, in this situation. The radio therapist either not well trained, or there is insufficient accessories to reduce the time inside the room. Radiotherapy department need a special considerations from the beginning of construction till starting of treatment. It is important to contain separate rooms, for planning to determine treatment area, another one for molding to shape lead blocks to protect normal parts and an optimum designed room for treatment to enable workers to apply basic radiation protection principles. (Author)

  9. Experimental investigation of cobalt-60 accumulation and elimination in Cyprinus carpio (L.)

    International Nuclear Information System (INIS)

    Fritsch, A.F.

    1985-11-01

    When introduced in cation form, 60 Co showed a distinct tendency to form anion or neutral complexes (50% and 20%, respectively); this was favorized by a high biomass content per liter of water. The ionic evolution of the radionuclide did not affect its accumulation level in the fish. Direct contamination predominated (70%) and the concentration factor at equilibrium was 10. Nutritional transfer from Limnaea to carp, after ingestion of 45 contaminated rations in 63 days, resulted in a low radionuclide retention factor (3 x 10 -3 ) that was not subject to bioamplification. Cobalt-60 was primarily eliminated via urine (60%), while the fecal matter contained only 20% of the radioactive isotope ingested in the food. The 60 Co content of carp contaminated from the water increased proportionally with the temperature. However, the 60 Co concentration did not vary significantly with the thermal factor, and the radionuclide concentration factor ranged from 4 to 6 between 8 0 C and 25 0 C. Decontamination was generally a two-phase process characterized by a short biological half-life ( 60 Co contained in the fish. The high 60 Co content of the digestive tract may be explained by fecal excretion of the radioactive isotope (30-40% of the elimination). The kidneys act as radionuclide elimination regulators via the urinary system [fr

  10. Research and design of the moving system for the cobalt-60 industrial irradiator VINAGA2

    International Nuclear Information System (INIS)

    Le Minh Tuan; Tran Khac An; Nguyen Ngoc Phuong; Tran Van Hung; Cao Van Chung; Phan Phuoc Thang; Ha Thanh Viet; Nguyen Thanh Cuong; Nguyen Duc Hoa

    2017-01-01

    On the way of localization of Cobalt-60 industrial irradiators, Research and Development Center for Radiation Technology (VINAGAMMA) has successfully designed and manufactured the first version of Co-60 industrial irradiator, VINAGA1. The second version of Co-60 industrial irradiator has been studied and designed by VINAGAMMA in the frame of the scientific project No. DTCB.02/15/TTNCTK. The main system of a Co-60 industrial irradiator is a mechanical system inside an irradiation room namely a tote box moving system. This report presents the tote box moving system of VINAGA2 designed by VINAGAMMA. The tote box moving system contains 52 tote boxes with the dimensions of 50 cm (w) × 70 cm (l) × 150 cm (h) that are moving around the source racks in the manner of 4 passes and 2 levels. The irradiator VINAGA2 with this tote box moving system has good specifications: The minimum time of an irradiation cycle is 1 h 20 min. and the dose uniformity ratio (DUR) at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 1.4 and 1.8, respectively. Radiation energy utilization efficiency at the product densities of 0.1 g/cm 3 and 0.5 g/cm 3 is 19.7% and 48.8%, respectively. These specifications meet the requirements for a multi-purpose Co-60 industrial irradiator and the present irradiation requirements in Vietnam. (author)

  11. Reconstruction of exposures to the public from a cobalt-60 irradiator facility

    International Nuclear Information System (INIS)

    Chapman, T.E.; Scherpelz, R.I.

    1992-01-01

    A study was performed for the US Department of Energy (DOE) to assess the radiation exposure received by the public from the operation of a cobalt-60 irradiator facility. Located south of Davis, California, at the former Laboratory for Energy-Related Health Research, the facility was an indoor-outdoor gamma irradiator operated for the DOE by the University of California, Davis. From 1970 to 1985, outdoor radiation exposure experiments conducted at the facility resulted in environmental radiation doses of 80 to 120 mSv per year along the facility's perimeter fence. Comprehensive environmental monitoring was not performed in the adjacent, uncontrolled areas and personnel who occupied these areas were not routinely monitored for radiation exposure. Because of incomplete environmental monitoring data, computer modeling was required to reconstruct the environmental dose rates present when the facility was in operation. Personnel occupancy times for the adjacent areas were determined from population statistics, historical records, and personal interviews. The potential dose equivalents calculated for the individuals who lived or worked in neighboring areas ranged from 0.02 to 3.6 mSv per year. These exposures, some of which exceed the current DOE standard of 1 mSv/y, were less than the DOE regulatory limit of 5 mSv/y for exposure to the public that was in effect when the facility was in operation

  12. Regression of uveal malignant melanomas following cobalt-60 plaque. Correlates between acoustic spectrum analysis and tumor regression

    International Nuclear Information System (INIS)

    Coleman, D.J.; Lizzi, F.L.; Silverman, R.H.; Ellsworth, R.M.; Haik, B.G.; Abramson, D.H.; Smith, M.E.; Rondeau, M.J.

    1985-01-01

    Parameters derived from computer analysis of digital radio-frequency (rf) ultrasound scan data of untreated uveal malignant melanomas were examined for correlations with tumor regression following cobalt-60 plaque. Parameters included tumor height, normalized power spectrum and acoustic tissue type (ATT). Acoustic tissue type was based upon discriminant analysis of tumor power spectra, with spectra of tumors of known pathology serving as a model. Results showed ATT to be correlated with tumor regression during the first 18 months following treatment. Tumors with ATT associated with spindle cell malignant melanoma showed over twice the percentage reduction in height as those with ATT associated with mixed/epithelioid melanomas. Pre-treatment height was only weakly correlated with regression. Additionally, significant spectral changes were observed following treatment. Ultrasonic spectrum analysis thus provides a noninvasive tool for classification, prediction and monitoring of tumor response to cobalt-60 plaque

  13. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    Energy Technology Data Exchange (ETDEWEB)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ({sup 60}Co) and examines how these characteristics affect the behavior of {sup 60}Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of {sup 60}Co production, waste types, and waste forms that contain {sup 60}Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom`s nucleus. There is only one stable isotope of cobalt, namely {sup 59}Co. All other cobalt isotopes, including {sup 60}Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ({sup 54}Co-0.19 s) to 5.2 years ({sup 60}Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of {sup 60}Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable {sup 59}Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. {sup 60}Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed.

  14. National Low-Level Waste Management Program Radionuclide Report Series: Volume 12, Cobalt-60

    International Nuclear Information System (INIS)

    Adams, J.P.

    1995-06-01

    This report outlines the basic radiological and chemical characteristics of cobalt-60 ( 60 Co) and examines how these characteristics affect the behavior of 60 Co in various environmental media, such as soils, groundwater, plants, animals, the atmosphere, and the human body. Discussions also include methods of 60 Co production, waste types, and waste forms that contain 60 Co. All cobalt atoms contain 27 protons (Z = 27) and various numbers of neutrons (typically N = 27 to 37 neutrons) within the atom's nucleus. There is only one stable isotope of cobalt, namely 59 Co. All other cobalt isotopes, including 60 Co, are radioactive. The radioactive isotopes of cobalt have half-lives ranging from less than a second ( 54 Co-0.19 s) to 5.2 years ( 60 Co). The radioactive isotopes of cobalt are not a normal constituent of the natural environment and are generated as a result of human activities. The primary source of 60 Co in the environment has been low-level radioactive waste material generated as a result of neutron activation of stable 59 Co that is present in the structural components of nuclear reactor vessels. This isotope is also intentionally produced, usually in reactors but also to some degree in accelerators for industrial and medical uses, such as for radiation sources for cancer treatment and nondestructive testing of metals and welds. 60 Co may enter the environment as a result of the activities associated with nuclear reactor operations and decommissioning and when industrial and medical sources are being used, manufactured, or disposed

  15. Late effects of protracted whole-body irradiation of beagles by cobalt-60 gamma rays

    International Nuclear Information System (INIS)

    Fritz, T.E.; Seed, T.M.; Tolle, D.V.; Lombard, L.S.

    1986-01-01

    So that a stronger basis for extrapolation of low-level radiation effects to man can be provided, existing data from small laboratory animals are being supplemented by studies in a longer lived animal, the dog. Beagle dogs are exposed to continuous cobalt-60 irradiation either throughout life or until predetermined total doses are accumulated. The radiation-specific excess-mortality rate and associated causes of death will be related to both dose rate and total dose. The ongoing studies also emphasize the pathogenesis of myelogenous leukemia. At dose rates of 3.75 to 26.25 rads/day, given continuously, responses were consistent, highly dose-rate dependent, and limited primarily to the hematopoietic system. At rates as low as 0.3 rad/day, the hematopoietic system is still the limiting factor for survival, but below 3.75 rads/day present evidence suggests that the responses are independent of dose rate. Longitudinal studies of peripheral blood and bone marrow detected four preclinical phases of myelogenous leukemia. These phases were characterized by standard hematologic end points, ultrastructural features, in vitro cloning assays, and the acute radiation sensitivity of stem cells. Results suggest that an induced error-prone repair mechanism is the basis for the onset of radiation-induced myelogenous leukemia. Interim data from dogs given terminated exposures suggest that the types of tumors and times to death are different from controls but the numbers of tumors are not yet greater than in controls. 26 refs., 12 figs., 5 tabs

  16. Development of a new model of actinic enteritis in rats using a cobalt-60 open source and a protection device as a collimator

    Energy Technology Data Exchange (ETDEWEB)

    Nunes, Vinicius Rodrigues Taranto; Vidigal, Paula Vieira Teixeira; Barbuto, Rafael Calvao; Duval-Araujo, Ivana, E-mail: vivas1912@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (UFMG), MG (Brazil); Pereira, Marcio Tadeu; Ladeira, Luis Carlos Duarte [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-03-15

    Purpose: To describe a new model of actinic enteritis that does not use radiotherapy machines. Methods: Sixteen Wistar rats were divided into four groups, consisting of four animals each: control (group A), two weeks after irradiation (group B), five weeks after irradiation (group C) and eight weeks after irradiation (group D). Animals were given a 10Gy radiation from a Cobalt-60 natural source in a nuclear technology research center. Protections of the surrounding tissues were obtained through the usage of plumb devices with a hole in the center, which served as a collimator. We obtained irradiated and non-irradiated colons from each animal. Results: In group B we found an important inflammatory response in the irradiated colon, which appeared in a reduced way in group C and was minimal in group D, in which we found a relevant collagen submucosal deposition/fibrosis. In all groups, the non-irradiated colon had a lower pathological damage in comparison with the irradiated colon. Conclusion: We thus described an efficient and feasible technique for obtaining an animal model of actinic enteritis. (author)

  17. Dosimetric Comparison of Real-Time MRI-Guided Tri-Cobalt-60 Versus Linear Accelerator-Based Stereotactic Body Radiation Therapy Lung Cancer Plans.

    Science.gov (United States)

    Wojcieszynski, Andrzej P; Hill, Patrick M; Rosenberg, Stephen A; Hullett, Craig R; Labby, Zacariah E; Paliwal, Bhudatt; Geurts, Mark W; Bayliss, R Adam; Bayouth, John E; Harari, Paul M; Bassetti, Michael F; Baschnagel, Andrew M

    2017-06-01

    Magnetic resonance imaging-guided radiation therapy has entered clinical practice at several major treatment centers. Treatment of early-stage non-small cell lung cancer with stereotactic body radiation therapy is one potential application of this modality, as some form of respiratory motion management is important to address. We hypothesize that magnetic resonance imaging-guided tri-cobalt-60 radiation therapy can be used to generate clinically acceptable stereotactic body radiation therapy treatment plans. Here, we report on a dosimetric comparison between magnetic resonance imaging-guided radiation therapy plans and internal target volume-based plans utilizing volumetric-modulated arc therapy. Ten patients with early-stage non-small cell lung cancer who underwent radiation therapy planning and treatment were studied. Following 4-dimensional computed tomography, patient images were used to generate clinically deliverable plans. For volumetric-modulated arc therapy plans, the planning tumor volume was defined as an internal target volume + 0.5 cm. For magnetic resonance imaging-guided plans, a single mid-inspiratory cycle was used to define a gross tumor volume, then expanded 0.3 cm to the planning tumor volume. Treatment plan parameters were compared. Planning tumor volumes trended larger for volumetric-modulated arc therapy-based plans, with a mean planning tumor volume of 47.4 mL versus 24.8 mL for magnetic resonance imaging-guided plans ( P = .08). Clinically acceptable plans were achievable via both methods, with bilateral lung V20, 3.9% versus 4.8% ( P = .62). The volume of chest wall receiving greater than 30 Gy was also similar, 22.1 versus 19.8 mL ( P = .78), as were all other parameters commonly used for lung stereotactic body radiation therapy. The ratio of the 50% isodose volume to planning tumor volume was lower in volumetric-modulated arc therapy plans, 4.19 versus 10.0 ( P guided tri-cobalt-60 radiation therapy is capable of delivering lung high

  18. Quarantine treatment in eggs of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), with gamma radiation of Cobalt-60; Tratamento quarentenário em ovos de Stenoma catenifer Walsingham (Lepidoptera: Elachistidae), com radiação gama do Cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Silva, L. K.F.; Arthur, V.; Nava, D. E.; Parra, J. R.P.

    2006-10-15

    The objective of this work has been to determine the lethal dose of gamma radiation of Cobalt-60 for the Stenoma catenifer eggs. For the irradiation of the eggs an irradiador Gammacell-220 (CO60) was utilized, (Rate dose: 1.054 kGY/h). The doses were: 0, 25, 50, 75, 100, 125 and 150 Gy, 90 eggs/dose (six repetitions). The number of caterpillars emerged was evaluated, and the survivors growed in seeds of avocado. The adults obtained were coupled with normal insects, growed in boxes with double face paper containing the food (10% honey) and a fruit of avocado. The experimental design was totally random, being the data submitted to the analysis of the varianza and the averages compared by the test of Tukey (P=5%). The emergence of caterpillars from the treated eggs with dose of 0, 25 and 50 Gy was verified. The dose of 50 Gy caused deformation in the caterpillars emerged. The effect of the gamma radiation in the viability of the eggs was proportional to the dose increase. The adults from the eggs dealt with 25 Gy presented non viabilty of 92,85 and 100% for male and female, respectively. A radiation gamma of 75 Gy is recommended for treatment quarantine for avocado fruits infested with of S. catenifer eggs.

  19. Transport of Cobalt 60 from the Argentine Nuclear Power Plant in Embalse

    International Nuclear Information System (INIS)

    Lopez Vietri, J.R.

    2011-01-01

    Full text: The purpose of this presentation is to point out some relevant issues related to the transport of cobalt 60 for domestic uses and export from the Argentine Nuclear Power Plant located in Embalse (ENPP). It is remarked that in last 22 years, ENPP produced about 2600 PBq (70 MCi) of Co-60, and that Argentina is the third Co-60 producer, after Canada and Russia. It is mentioned that in Argentina there are facilities which manufacture Zircaloy seamless tubes and reactivity control bars containing cobalt 59 to be used in ENPP, the operation of Candu reactor at ENPP including cobalt-related activities, and the manufacture and commercialization of Co-60 sealed sources. The Argentine Nuclear Regulatory Authority verifies the compliance of nuclear activities with regulatory standards, including those related to the transport of radioactive material. Then, it is described the process for obtaining Co-60 at ENPP with an activity concentration to allow its use in medicine and industry. After that, is considered in detail the type of package used for the transport of Co-60 from ENPP: it is to say, Type B(U) package designs that must be approved by the Competent Authority origin of the design, and they are able to withstand routine, normal and accident conditions of transport, including severe impacts, fires and immersion in water. The overall dimensions of packages are about 1.0 m to 1.5 m diameter by 1.2 m to 1.8 m high, as well as the gross mass could vary from 6500 kg to 9500 kg. Radioactive contents consist of Co-60 sealed sources (called pencils), with an activity range from 8 PBq to 16 PBq. Then, it is considered activities prior to dispatch of Type B(U) packages at ENPP, including the preparation of radioactive contents, packaging and package (labelling and marking) as well as necessary tests and documentation for transport in order to fulfil pertinent requirements of package design operation manual of the package and related standards. Finally, it is pointed

  20. Autonomous monitoring unit, signs and registration for Cobalt-60 irradiator safety system

    Energy Technology Data Exchange (ETDEWEB)

    Baldaconi, Ricardo H.; Costa, Fabio E. da, E-mail: ricardohovacker@hotmail.com, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7- 200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cell phones. The circuit uses two microcontrollers called 'main' and 'secondary'. The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is

  1. Autonomous monitoring unit, signs and registration for Cobalt-60 irradiator safety system

    International Nuclear Information System (INIS)

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2015-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7- 200 from Siemens and a relay logic. From a set of information, the both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides besides a monitoring the entire process by a synoptic table on the computer screen, also keeps records of all events on the computer's hard drive. The electronic management has proven to be efficient and has not produced any failure that had compromised the safety. The PLC along with the relay logic has always taken the right decisions ensuring proper radiation protection of operators and the integrity of radioactive sources, but it presented over the years of operation (beginning in 2004) less than a dozen flaws in system event log. The deficiency was found between the process of sending events via serial communication (EIA232) to the supervisory program. When failure occurs in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. This work aimed to build a standalone electronics connect the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system. It records each event on a memory card, waits for the right decision of the security system and in case of an incorrect decision an independent alarm notifies its own synoptic picture, and sends a text message to a group of defined cell phones. The circuit uses two microcontrollers called 'main' and 'secondary'. The main is responsible for the control and monitoring of peripheral inputs and outputs of the security system. The main is

  2. Effects of whole-body cobalt 60 gamma irradiation on the young korean native goats

    International Nuclear Information System (INIS)

    Kim, Jong Gyu; Sung, Jai Ki

    1989-01-01

    This study was carried out to investigate the effects of whole-body cobolt-60 gamma irradiation on clinical signs, mortality, hematological, blood chemical, chromosomal and pathologic changes in the young Korean native goats. Groups of goats were exposed to 200, 400, 600 and 800 rads of gamma irradiation from a cobalt-60 source. Clinical signs such as diarrhea, anorexia, weakness and depression of the irradiated goats were observed. Mortalities were 66.7 percent in the group irradiated with 200 rads and 100 percent in the groups irradiated with higher doses. Death times were shortened with the increment of irradiation doses. With time after irradiation, the values of erythrocytes, hemoglobin and packed cell volume decreased in the 200 and 400 rads groups and increased in the 600 and 800 rads groups. The number of total leukocytes of the irradiated goats decreased significantly in all irradiated groups. The degrees of decrease were severe as the irradiated doses were increased. Significant decrease of lymphocyte counts were observed from 6 hours in the 800 rads group and 1 day post irradiation(PI) in all other groups. Post irradiation times for significant reduction of neutrophils were 1, 3, 3 and 5 days for 800, 600, 400 and 200 rads groups, respectively. Serum sorbitol dehydrogenase and serum aspartate aminotransferase activities increased remarkably at 6 hours PI in the 800 rads group and 1 day PI in all other groups. Thereafter the activities returned to normal values. Since mitoses of lymphocytes were completely inhibited in blood cultures of all irradiated goats, chromosomal pictures could not be observed. However, mitoses were observed on 28 days PI in 200 rads group and no abberration in the number and structures of lymphocyte chromosomes were detected. Histopathologic findings in various organs of the irradiated goats were severe necrosis and depletion of lymphoid cells in the lymph nodes and spleen, hypoplasia of hemopoietic cells in the bone marrow

  3. Use of gamma radiation cobalt 60 for disinfestation of Lasioderma serricorne (Fabricius, 1972) (Coleoptera: Anobiidae) in Chamomilla recutita L. and Pimpinela anisum L. dehydrated

    International Nuclear Information System (INIS)

    Alves, Juliana Nazare; Potenza, Marcos Roberto

    2008-01-01

    Stores products such a grains, flours, dry fruits and spices are normally infested by pests as beetles (Lasioderma serricorne), mites and moths, depreciating the product visually and promoting its deterioration. To improve the quality of spices, medicinal plants and others foodstuffs there is a need for adequate methods of handling, correct identification of the species, adequate collection and storage. The objective of this work was to determine the dose of gamma radiation for the disinfestation of medicinal and aromatic plants infested by L. serricorne. The plants used in this study were Chamomilla recutita L. and Pimpinela anisum L. in this dehydrated form. The experiment was carried out in the Laboratorio de Inseticidas e Acaricidas from Instituto Biologico/SP, during the months of January and May 2006, and the irradiations were carried out in the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN/SP, using and experimental Cobalt 60 irradiator, model Gammacell 220. Each treatment consisted of 5 parcels containing 10 g of dehydrated products infested with 20 last instar larvae of L. serricorne, conditioned in plastic 10 x 10 cm containers with small punctures in the cover to allow internal aeration. The substratum previously infested was submitted to increasing doses of gamma radiation: 0: 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.0; 2.25; 2.50 and 2.75 kGy. After irradiation, the samples were kept in a acclimatized room at 27 ± 2 deg C of temperature and relative humidity of 70 ± 5% and after a 45 days period the number of adults insects emerged was evaluated. The disinfestation dose of gamma radiation for last instar larvae L. serricorne on Chamomilla recutita L. and Pimpinela anisum L. was 2.0 kGy. (author)

  4. Use of gamma radiation cobalt 60 for disinfestation of Lasioderma serricorne (Fabricius, 1972) (Coleoptera: Anobiidae) in Chamomilla recutita L. and Pimpinela anisum L. dehydrated

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Juliana Nazare; Potenza, Marcos Roberto [Instituto Biologico, Sao Paulo, SP (Brazil). Centro de Pesquisa e Desenvolvimento de Sanidade Vegetal]. E-mail: julianaabc@ig.com.br; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)]. E-mail: arthur@cena.usp.br

    2008-03-15

    Stores products such a grains, flours, dry fruits and spices are normally infested by pests as beetles (Lasioderma serricorne), mites and moths, depreciating the product visually and promoting its deterioration. To improve the quality of spices, medicinal plants and others foodstuffs there is a need for adequate methods of handling, correct identification of the species, adequate collection and storage. The objective of this work was to determine the dose of gamma radiation for the disinfestation of medicinal and aromatic plants infested by L. serricorne. The plants used in this study were Chamomilla recutita L. and Pimpinela anisum L. in this dehydrated form. The experiment was carried out in the Laboratorio de Inseticidas e Acaricidas from Instituto Biologico/SP, during the months of January and May 2006, and the irradiations were carried out in the Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN/SP, using and experimental Cobalt 60 irradiator, model Gammacell 220. Each treatment consisted of 5 parcels containing 10 g of dehydrated products infested with 20 last instar larvae of L. serricorne, conditioned in plastic 10 x 10 cm containers with small punctures in the cover to allow internal aeration. The substratum previously infested was submitted to increasing doses of gamma radiation: 0: 0.5; 0.75; 1.0; 1.25; 1.50; 1.75; 2.0; 2.25; 2.50 and 2.75 kGy. After irradiation, the samples were kept in a acclimatized room at 27 {+-} 2 deg C of temperature and relative humidity of 70 {+-} 5% and after a 45 days period the number of adults insects emerged was evaluated. The disinfestation dose of gamma radiation for last instar larvae L. serricorne on Chamomilla recutita L. and Pimpinela anisum L. was 2.0 kGy. (author)

  5. Use of gamma radiation cobalt 60 for disinfestation of Lasioderma serricorne (Fabricius, 1972) (Coleoptera: Anobiidae) in Cymbopogon citratus stapf and Ocimun basillicum L. dehydrated

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Amanda C.O.; Potenza, Marcos R.; Alves, Juliana N.; Justi Junior, Joao [Instituto Biologico, Sao Paulo, SP (Brazil). Centro de Pesquisa e Desenvolvimento de Sanidade Vegetal]. E-mail: potenza@biologico.sp.gov.br; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil)]. E-mail: arthur@cena.usp.br

    2007-07-01

    Stored products such as grains, flours, dry fruits and spices are normally infested by pests as beetles (Lasioderma serricorne), mites and moths, depreciating the product visually and promoting its deterioration. To improve the quality of spices, medicinal plants, seasoning and others foodstuffs there is a need for adequate methods of handling, correct identification of the species, adequate collection, pre and post-treatment procedures and adequate storage. The objective of this work was to determine the dose of gamma radiation for the disinfestations of medicinal and aromatic plants dehydrated infested by L. serricone. The plants used in this study were Cymbopogon citratus stapf (lemon grass) and Ocimun basillicum L. (basil) in this dehydrated form. The experiment was carried out in the Arthropods Laboratory of the Instituto Biologico/SP, during the months of January and May 2006, and the irradiations were carried out in the Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN/SP, using an experimental Cobalt 60 irradiator, model Gammacell 220. Each treatment consisted of 5 parcels containing 10g of dehydrated products infested with 20 last instar larvae of L. serricorne, conditioned in plastic 10x10 cm containers with small punctures in the cover to allow internal aeration. The substratum previously infested was kept for 1 day in a acclimatized room at 27 {+-} 2 deg C, after this period the substratum was submitted to increasing doses of gamma radiation: 0; 0,5; 0,75; 1,0; 1,25; 1,50; 1,75; 2,0; 2,25; 2,50 e 2,75 kGy. After irradiation, the samples were kept in a acclimatized room at 27 {+-} 2 deg C of temperature and relative humidity of 70 {+-} 5 % and after a 45 days period the number of adults insects emerged was evaluated. The lethal dose of gamma radiation for L. serrricorne last instar larvae on Cymbopogon citratus stapf and Ocimun basillicum L. was 1,75 kGy. (author)

  6. SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

    International Nuclear Information System (INIS)

    Xu, L; Smith, L; Ciresianu, A

    2016-01-01

    Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

  7. SU-F-T-530: Characterization of a 60-Leaf Motorized MLC Designed for Cobalt-60 Units

    Energy Technology Data Exchange (ETDEWEB)

    Xu, L; Smith, L; Ciresianu, A [Best Theratronics, Ottawa, ON (Canada)

    2016-06-15

    Purpose: In a continuing effort to improve conformal radiation therapy with Cobalt-60 units, a 60-leaf MLC was designed, manufactured, and released to market. This work describes the physics measurements taken to characterize the clinical performance of this MLC. Methods: A 60 leaf MLC was custom designed with tungsten leaves of 4.5 cm height, single focused, achieving field size of 30×30 cm^2 when mounted on a 100cm SAD Cobalt-60 unit. Leakage and output factor measurements were performed using a single ion chamber in a solid water phantom. Penumbra and surface dose were measured using scanning chambers and diodes in a water phantom. Radiation-light coincidence measurements were performed using radiographic films. Results: With MLC mounted, measured penumbras at all depths are smaller than with jaws only. Surface doses were not significantly affected by the presence of MLC, and remained below values recommended by regulatory bodies. Light-radiation coincidences were found to be better than 3 mm for all field sizes. Leakage through the MLC was found to be strongly dependent on field size, increasing from 1.0 % for a 10×10 cm field to 2.0% for a 30×30 cm field. Such results meet the requirements of IEC 60601-2-11. The MLC was found to have significant influence on the output factor, when field size defined by MLC is significantly smaller than field size defined by jaws. Such effect is also observed on linear accelerators, but it is more pronounced on Cobalt-60 units. A 10×10 “diamond” MLC shape inside a 14×14 cm jaw showed output factor that is 5.7% higher than 10×10 cm field defined by matching MLC and jaws. Conclusion: The MLC offers clinically acceptable performance in penumbra, surface dose, and light-radiation coincidence. Several units of this MLC have recently been installed and used clinically. Validation of Cobalt-60 based IMRT with this MLC is ongoing. The authors are employees of Best Theratrnics Ltd.

  8. Progeny of Spalangia endius Walker, 1839 (Hymenoptera: Pteromalidae) in Musca domestica L., 1758 (Diptera: Muscidae) non-viable pupae irradiated by gamma Cobalt-60 and cold stored

    International Nuclear Information System (INIS)

    Itepan, Sara Eloiza Zen.

    1992-06-01

    This study was designed to test acceptability of cold stored irradiated and non-irradiated pupae of Musca domestica L., 1758 (Diptera: Muscidae) by the parasitoid Spalangia endius Walker, 1839 (Hymenoptera: Pteromalidae). The work was carried out in the laboratory of the Entomology Section of the Center of Nuclear Energy in Agriculture (CENA/USP) and in the laboratory of Biological Control of House Flies Eduardo Hiroshi Mizumoto of Entomology Department of the College of Agriculture Luiz de Queiroz (ESALQ/USP), Piracicaba, Sao Paulo, Brazil. The gamma radiation source used was a Cobalt-60 irradiator, Gamma bean-650, with an initial activity of 1,6265 x 10 4 Bq (6,746 Ci). The radiation LD 50 e LD 100 , using a dose ratio of 1457 Gy/h, for 12, 24, 36, 48, 60 and 72 hours old pupae and resulted in 15.35; 15.69; 11.30; 49.4; 142.78 and 175 Gy for LD 50 and 20, 22.5; 32.5; 175; 225 and 300 Gy for LD'1 00 respectively. Following exposure, the pupae were kept in climate chamber at 27 ± 3 0 C and 75 ± % of relative humidity, until all adults had emerged. In succession, 24, 48 and 72 hour-old pupae were exposed to gamma irradiation with a dose of 1440 Gy/hour, in their respective lethal doses. Following the exposure the pupae were stored at cool temperature (10 ± 2 0 C) for different periods of time (5, 15, 20 and 30 days). The same treatment was given for non-irradiated pupae. After the storage period the pupae were expose for 24 h to S. endius in a ratio of 1:10 parasitoid-host. It was not observed any statistical difference (Turkey 5%) in progeny of males and females emerged from irradiated and non-irradiated pupae. There was a preference of the parasitoid to pupae of 48 hours old followed by 24 and 72 hours old for storage period more than 5 days and shorter than 20 days. (author). 50 refs., 6 figs., 17 tabs

  9. Physico chemical and microbiological changes in nopal (Opuntia spp.) irradiated with gamma rays of cobalt 60

    International Nuclear Information System (INIS)

    Perez N, M.

    2001-01-01

    The objective of this work is to study the physico-chemical and microbiological changes which take place in the nopal (Opuntia spp.) after they have been irradiated and stored at environment and refrigeration temperatures in order to determine the level of irradiation dose more adequate for getting them an increase in the storage life, as well as to determine the physico-chemical changes attributed to the irradiation doses used, comparing the obtained results with those ones of non-irradiated nopal samples, which are considered as control samples. The radiation source used was a GAMMABEAM-651 PT, property of the Nuclear Sciences Institute of UNAM. The nopals studied are of the variety (Milpa Alta, Opuntia ficus) which were cut and packed in polyethylene bags with and without nitrogen. In order to find the adequate dose level it was used a lot of 200 samples which were treated in sets of 10. They were irradiated in doses of 0.5 to 10 kGy at a dose reason of 3.7 kGy/h. The adequate doses for getting an increase in the storage life, where there was not darkness were of 1.5 and 2.0 kGy, allowed doses in the NOM-033-SSA1-1993, it was not found any change in acceptability by flavour, but so in the titled activity values and sugars. The lowest loss of weight was found in the 1.5 kGy dose without nitrogen and the highest in the 2.0 kGy with nitrogen dose. Likewise was determined that with the irradiation treatment in the recommended doses it is diminished the microorganisms growth, obtaining an improvement in the general appearance of the nopals during their storage period. (Author)

  10. Effects of gamma radiation of Cobalt-60 on arabica and conillon seeds coffea: physic-chemistry evaluation; Efeitos da radiacao gama do Cobalto-60 em sementes de cafe arabica e conillon: avaliacao fisico-quimica

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Marcus Henriques da

    2012-07-01

    Brazil is the largest producer and exporter of coffee in the world. The coffee bean is one of the main products of the Brazilian trade balance. Two species of coffee are the most economically important: the Coffea arabica L. and Coffea canephora Pierre is the largest representative of the Coffea canephora Pierre is the coffea conillon. Food irradiation is an area of research that aims to increase the shelf life of foods and controlling pests. This study aimed to verify the physicochemical variables of Arabica coffee and conillon were affected when exposed to doses of gamma radiation from cobalt-60. The samples were provided by Polo in Coffee Quality Technology, Federal University of Lavras - UFLA. The coffee samples were subjected to irradiation doses: 0 (control), 5 kGy and 10 kGy, a multipurpose irradiator of IPEN - Research Institute of Nuclear Energy and the University of São Paulo, at a rate of 7.5 kGy / hour. For irradiation the samples were vacuum-packed in appropriate packaging aluminised. After the process of irradiation the samples were stored at a temperature of 15 ± 1 deg C and relative humidity of 17 ± 1%. The following analyzes were performed: levels of total sugars, glucose, sucrose, caffeine, humidity, pH, total acidity, electrical conductivity and fibers. Analyses were performed 1, 30, 60 and 90 days after irradiation, and the results were submitted to analysis of variance and means were compared by Tukey test at 5%. It was observed that the analysis results of the samples irradiated with 5 kGy and 10 kGy showed values similar to the control. It was concluded that irradiation did not induce deleterious effects on arabica coffee seeds and conillon irradiated with 5 kGy and 10 kGy to 90 days after irradiation. (author)

  11. Sensory evaluation of black beans submitted to gamma radiation from Cobalt-60

    International Nuclear Information System (INIS)

    Moura, Neila Camargo de; Canniatti-Brazaca, Solange Guidolin; Spoto, Marta Helena Fillet; Arthur, Valter

    2005-01-01

    The objective of this research was to evaluate the sensory aspects of black beans submitted to gamma radiation from 60 Co. The study involved eight panelists, between 17 to 23 years old, who were selected and trained for the descriptive analysis of appearance, aroma, flavor and texture. The panelists analyzed alterations of appearance, aroma, flavor and texture of non-irradiated and irradiated black beans with doses 2, 4, 6, 8 and 10kGy. The results were analyzed by test F, ANOVA and the Tukey test (5%), with the use of computers and the sensory analysis software Compusense Five and SAS. The results showed that irradiated samples decreased the bitter flavor, accentuated color and brightness and samples non-irradiated dry texture. The radiation treatment is a good method for conservation of black beans in doses evaluated in this study.(author)

  12. The use of Gamma radiation of Cobalt-60 to control avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit of Persea americana (Miller) (Lauraceae)

    International Nuclear Information System (INIS)

    Silva, Lilian Karla Figueira da

    2004-01-01

    This work aimed to evaluate the influence of Gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit Persea americana (Miller) (Lauraceae). For this research, insects were irradiated in ali phases of their life cycle with doses varying from O to 600 Gy and they were maintained at the temperature of 25 +- 2 deg C, humidity of 70 +- 10% and photo phase of 14 h. The species was raised on natural diet, avocado seeds. The cultivar fruits Geada were irradiated with doses that varied from 0 to 150 Gy, maintained for 15 days at room temperature (20 a 35 deg C and humidity of 70 - 80 %) and 30 days at a temperature of 10 deg C, humidity of 40 - 60 %. The chemical-physics and sensorial analyses were carried out. According to the obtained results, it was verified that the lethal dose of gamma radiation to S. catenifer eggs, was of 75 Gy; for caterpillars and pupas was of 300 Gy. The sterile-dose for upcoming adults from irradiated S. catenifer eggs was of 25 Gy; for upcoming adults from irradiated caterpillars, it was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The irradiation in the avocado fruit, maintained at room temperature for 7 days of storage, caused change in the coloration of the fruit (dark spots and yellowish coloration) and more firmness. The sensorial characteristics were kept and the irradiated fruit was the chosen one as favorite for tasting. The irradiated fruits that were kept at 10 deg C, obtained an increase in the storage period, without changing their chemical physics characteristics. The coloration of the fruits was kept, more firmness and a subtle acidity taste increase, being effective in the conservation of the fruits and in the maintenance of their sensorial characteristics. The use of the gamma radiation as treatment quarantine of S. catenifer it was efficient, should be treated them with

  13. External cobalt 60 irradiation alone for stage IIB carcinoma of the uterine cervix

    International Nuclear Information System (INIS)

    Lei, Z.Z.; He, F.Z.

    1989-01-01

    From 1964 to 1980, 97 patients with Stage IIb carcinoma of cervix uteri were treated by external 60Co irradiation alone. Of these 97 patients, 94 (96.9%) had squamous cell carcinoma. The parametrial extension of the lesion almost reached the pelvic wall in 73.2% and vaginal extension reached to the upper half of vaginal in 24.7% of the patients. A tumor dose of 60 Gy was given to the whole pelvis by a four field technic (opposing parallel AP and lateral portals) in 6-8 weeks. A booster dose of 10 Gy was delivered to the cervix by a pair of reduced opposing parallel AP portals or a perineal portal in a week. The doses delivered were equivalent to the Time-Dose-Fractionation (TDF) value of 110-130 at the center of pelvis and 90-110 in the whole pelvis. The 5-year survival rate for all 97 patients was 56.7%. It was 59.8% when those who died of other diseases were excluded. The prognosis of patients without residual tumor on the cervix and/or vagina was better than that with residual tumor (p less than 0.01). Thirty-seven patients died of cancer (23 died of recurrence, 8 of distant metastases, 2 of both, and 4 were lost before the fifth year). Of these 37 patients, 97.3% died within 3 years after initial treatment. During the radiation treatment, reactions were moderate. Late complications included 19 (19.6%) with mild cystitis and 16 (16.5%) with mild proctitis, 2 (2.7%) developed recto-vaginal fistula. These results were slightly poorer than those using intracavitary and external irradiation or the combination of preoperative irradiation plus surgery. Yet, for patients with extensions nearing the pelvic wall or with contra-indications to surgery or intracavitary radiotherapy, external irradiation alone is still of value

  14. Effects of gamma radiation from Cobalt 60 on eggs and adults of Sitotroga cerealella (Oliver, 1819) (Lepidoptera, Gelechiidae) in laboratory

    International Nuclear Information System (INIS)

    Rodrigues, Z.A.; Rego, A.M.; Oliveira, M.L. de; Ferreira, D.

    1983-01-01

    Lethal and sterilizing dosages from Cobalt-60 radiations were determined for Sitotroga cerealella (Oliver, 1819) eggs and adults. Eggs at the age of 0 to 24 hours were irradiated with dosages of 0,1,2; 4,6,8,10 and 12 krad; it was observed that 10 krad killed all embryos although this was not observed in 96 hours old eggs. A new group was irradiated with dosages of 0,60,80,100,120 and 140 krad, and complete lethal dosage was determined as 140 krad. Mating of irradiated with non irradiated insects resulted in 100% infertile eggs when either the males or females had received the dosage of 100 krad. Imediate lethality of S. cerealella adults was not observed with the dosages of 300 to 320 krad but all insects died after two days (L sup(D) 100/ 2 ). (Author) [pt

  15. Study of ozone gas formed in the industrial radiation process with cobalt-60 and its impact on the environment

    International Nuclear Information System (INIS)

    Uzueli, Daniel Henrique

    2013-01-01

    The radiation processing is present in various products such as foods, medical disposable, electrical cables, gems, among others. This process aims to improve the properties, sterilize or sanitize irradiated products. In industrial irradiators facilities, electromagnetic radiation (gamma and X-rays) or electrons before they interact with the products in processing, there are a layer of air. To interact with this air layer, it causes radiolytic effects on the molecules present in the ambient atmosphere, and the main interaction are with the oxygen molecules that have their bonds broken, separating them into two highly reactive atoms that recombine with the other molecule of oxygen to form ozone gas. In this work it was studied the formation, decay and dispersion of ozone in industrial gamma irradiators facilities that use cobalt-60 as a source of radiation. The monitoring of ozone concentration was performed by optical absorption method in a commercial monitor. (author)

  16. Use of gamma radiation cobalt 60 for disinfestation of Lasioderma serricorne (Fabricius, 1972) (Coleoptera: Anobiidae) in Cymbopogon citratus stapf and Ocimun basillicum L. dehydrated

    International Nuclear Information System (INIS)

    Ramos, Amanda C.O.; Potenza, Marcos R.; Alves, Juliana N.; Justi Junior, Joao

    2007-01-01

    Stored products such as grains, flours, dry fruits and spices are normally infested by pests as beetles (Lasioderma serricorne), mites and moths, depreciating the product visually and promoting its deterioration. To improve the quality of spices, medicinal plants, seasoning and others foodstuffs there is a need for adequate methods of handling, correct identification of the species, adequate collection, pre and post-treatment procedures and adequate storage. The objective of this work was to determine the dose of gamma radiation for the disinfestations of medicinal and aromatic plants dehydrated infested by L. serricone. The plants used in this study were Cymbopogon citratus stapf (lemon grass) and Ocimun basillicum L. (basil) in this dehydrated form. The experiment was carried out in the Arthropods Laboratory of the Instituto Biologico/SP, during the months of January and May 2006, and the irradiations were carried out in the Instituto de Pesquisas Energeticas e Nucleares-IPEN/CNEN/SP, using an experimental Cobalt 60 irradiator, model Gammacell 220. Each treatment consisted of 5 parcels containing 10g of dehydrated products infested with 20 last instar larvae of L. serricorne, conditioned in plastic 10x10 cm containers with small punctures in the cover to allow internal aeration. The substratum previously infested was kept for 1 day in a acclimatized room at 27 ± 2 deg C, after this period the substratum was submitted to increasing doses of gamma radiation: 0; 0,5; 0,75; 1,0; 1,25; 1,50; 1,75; 2,0; 2,25; 2,50 e 2,75 kGy. After irradiation, the samples were kept in a acclimatized room at 27 ± 2 deg C of temperature and relative humidity of 70 ± 5 % and after a 45 days period the number of adults insects emerged was evaluated. The lethal dose of gamma radiation for L. serrricorne last instar larvae on Cymbopogon citratus stapf and Ocimun basillicum L. was 1,75 kGy. (author)

  17. Cobalt-60 oxide aerosols: methods of production and short-term retention and distribution kinetics in the beagle dog

    International Nuclear Information System (INIS)

    Barnes, J.E.; Kanapilly, G.M.; Newton, G.J.

    1976-01-01

    Cobalt-60 has been used extensively in nuclear applications and has been considered for use in nuclear auxiliary power devices. The most common chemical form used is the oxide. This study of the retention and distribution of two differnt exoides of cobalt when administered by inhalation was conducted to assess the potential inhalation hazard associated with its use. Cobaltosic oxide (Co 3 O 4 ) was formed by passing a cobalt nitrate aerosol through a heating column at 850 0 C before delivery to the dog. Cobaltous oxide (CoO) was formed by raising the heating column temperature to 1400 0 C. Three beagle dogs were exposed to 60 Co 3 O 4 and sacrificed singly at 8, 64 and 128 days. Three beagle dogs were exposed to 60 CoO and sacrificed at 8, 16 and 64 days after exposure. Whole-body retention patterns showed that 60 CoO left the body with a shorter effective half-life than 60 Co 3 O 4 . The concentration of 60 Co detected in the blood was at least an order of magnitude higher in the dogs exposed to 60 CoO than in the dogs exposed to 60 Co 3 O 4 . Cobalt-60 translocated from the lung accumulated predominantly in the kidney, liver, skeleton and cartilagenous structures such as the trachea. Higher concentrations were reached earlier in the dogs exposed to 60 CoO. After early fecal excretion of material deposited in the upper respiratory tract, excretion was greatest via the urine. The higher solubility of the 60 CoO formed at 1400 0 C relative to 60 Co 3 O 4 formed at 850 0 C is noteworthy considering that generally aerosols formed at higher temperatures are more insoluble than aerosols formed at lower temperatures. (author)

  18. The ''Cobalt 60 Case'' in Taiwan. Conclusions; Das Kobalt-60 Ereignis von Taiwan. Und was ist daraus zu schliessen?

    Energy Technology Data Exchange (ETDEWEB)

    Niemann, Lutz

    2017-08-15

    The ''Cobalt 60 Case'' in Taiwan gives an opportunity for check of the thesis of radiation hormesis. Apartment residents have been exposed to cobalt-60 contaminated steel buildings. The results of a study strongly suggest that whole-body chronic irradiation, in the dose rate range that the apartment residents received, caused no symptomatic adverse health effects, such as radiation sickness, or the increased cancer or increased congenital disease that are predicted by ICRP theories. On the contrary, those who were exposed had lower incidences of cancer mortality and congenital malformations.

  19. Molecular Effects of Irradiation (Cobalt-60 on the Control of Panonychus citri (Acari: Tetranychidae

    Directory of Open Access Journals (Sweden)

    Ke Zhang

    2015-11-01

    Full Text Available The effective dose of irradiation to control pest mites in quarantine has been studied extensively, but the molecular mechanisms underlying the effects of the irradiation on mites are largely unknown. In this study, exposure to 400 Gy of γ rays had significant (p < 0.05 effects on the adult survival, fecundity and egg viability of Panonychus citri. The irradiation caused the degradation of the DNA of P. citri adults and damaged the plasma membrane system of the egg, which led to condensed nucleoli and gathered yolk. Additionally, the transcriptomes and gene expression profiles between irradiated and non-irradiated mites were compared, and three digital gene expression libraries were assembled and analyzed. The differentially expressed genes were putatively involved in apoptosis, cell death and the cell cycle. Finally, the expression profiles of some related genes were studied using quantitative real-time PCR. Our study provides valuable information on the changes in the transcriptome of irradiated P. citri, which will facilitate a better understanding of the molecular mechanisms that cause the sterility induced by irradiation.

  20. Effects of gamma radiation from Cobalt-60 on pequi fruits (Caryocar brasiliense Camb.);Efeitos da radiacao gama do Cobalto-60 em frutos de pequi (Caryocar brasiliense Camb.)

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Marcio Ramatiz Lima dos

    2008-07-01

    The aim of this work was to evaluate gamma radiation effects from Cobalt-60 on post harvest characteristics of pequi fruits (Caryocar brasiliense Camb.). Brazilian savannah is the second biome of American Continent and concentrate a lot of plants and animal species. Many plants and their fruits are still unknown of Brazilian population. Just now, they are gained attention of researchers due their nutritional properties, between then is the pequi fruits. Fruits come from Goias State was classified, washed and processed to separate the endocarp (edible part) from pericarp. The endocarps were packing in polyethylene bags with 150 g, labeled and submitted to radiation process (0.0, 0.4, 0.6 and 1.0 kGy doses) on multipurpose irradiator located in IPEN/USP. The samples were analyzed to chemical (pH, trititable acidity, Deg Brix, ratio TSS/TTA, lipids, ash, humidity, protein, soluble and insoluble fiber, total carotenoids and antioxidant activity) and physical properties (loss weight, texture and color). The loss humidity was proportional to radiation applied doses, the highest loss was observed on fruits to 1.0 kGy doses. Soluble fiber and protein showed no significant differences between treatments. Ash, insoluble fiber, dry matter and lipids showed little significant differences. Significant decrease of the pH values was observed for the irradiated samples in relation to control. Irradiated samples texture showed significant increase compared to control, but showed no significant differences between applied doses. The higher value for texture was (39.89 Newton g-1) for 0.6 kGy dose. Total soluble solids (TSS) showed a significant decrease compared to control, but was not significant between applied treatments. Titratable acidity showed a significant decrease for irradiated samples compared to control for all doses, but it was not significant between treatments. The ratio TSS/TTA showed no significant differences compared to control, only for irradiated fruits at 0.6 kGy

  1. Effect of cobalt-60 gamma irradiation on viability of soybean (glycine max. l) seed

    International Nuclear Information System (INIS)

    Addai, Isaac Kwahene

    2001-12-01

    The rapid rate of deterioration and low viability of soybean seeds particularly in storage is a major constraint to its production in the subtropical and tropical areas. Various approaches have been made to solve this problem but they have centred mainly on the control of the environment. Experimental mutagenesis is one of the ways by which genetic variability could be created to serve as basis for selection. In this study, induced mutations were used to create genetic variation and mutants with improved storability selected to provide a more lasting solution to this problem. Seeds of three soybean varieties - Gmx 92-6-10, Gmx 92-5-4E and TGX 87D- 1303 were subjected to four (4) months ambient storage and three accelerated ageing tests. The germination percentages computed 7 days after planting showed that 20% ethanol solution better mimicked ambient storage than 20% methanol solution and the 75°C hot water. In the radiation dosage response studies, dry seeds containing 10% moisture from the three varieties were subjected to 0, 50, 100, 150, 200 and 250 Gy doses of 60Co gamma rays at Ghana Atomic Energy Commission, Kwabenya and sown. The 250 Gy dose reduced both germination percentage and plant height by about 50% relative to the control and was used as the dosage appropriate for induced mutations for the varieties. Five thousand M2 plants were harvested and screened individually for improved storability using 20% ethanol solution, storing threshed seeds at ambient condition and storing seeds in pods also at ambient conditions. The 20% ethanol solution was less effective in selecting putative in mutants compared to the two ambient storage screening methods, but could be used as an initial screening method. The variety Gmx 92-6-10 was generally considered to give the greatest response to irradiation because it produce the largest proportion of putative mutant improved storability in two out of the three screening methods used at the M2 generation. Since TGX 87D 1

  2. Degradation of the insecticide ethyl parathion in different environmental matrices by gamma radiation from Cobalt-60; Degradacao do inseticida paration etilico em diversas matrizes ambientais por meio de radiacao ionizante gama do cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Luchini, Luiz Carlos

    1995-07-01

    This work studies the use of gamma radiation from cobalt-60 to induce parathion degradation in different matrices, as well as, quantified GC-NPD and identified by GC-MS, the radiolysis resulting products. Results show that the insecticide was completely degraded in aqueous solution after treatment with 1.0 kGy dosis in a dosis rate of 3.12 kGy h{sup -1}. In methanol, parathion was completely degraded only with 30 kGy at 3.12 kGy h{sup -1}. The metabolites detected after radiolysis were the same formed by biological degradation, i.e, p-nitrophenol, p-aminophenol, paraoxon and aminoparathion. The gamma radiation also degraded paraoxon which is the most toxic metabolite of parathion. It was verified that, not only the total radiation, but also the dosis rate supplied to the aqueous solution had a significant effect on the insecticide degradation, and the formation of metabolites occurred in a selective way respecting the dosis and dosis rate. Otherwise, the gamma radiation did almost not degraded the parathion adsorbed in solid matrices as rice, moist and dry soil, even using dosis of 5,30 and 50 kGy, respectively. The parathion yield and the dosis of gamma radiation needed for 50% reduction of the insecticide initial concentration in aqueous solution were also calculated and presented. Thus, it was verified that irradiation of parathion besides to be an important instrument for environmental decontamination of this pesticide in aqueous matrix, it allows the production of parathion metabolites for ecotoxicological studies. (author)

  3. Re-Shielding of Cobalt-60 Teletherapy Rooms for Tomotherapy and Conventional Linear Accelerators using Monte Carlo Simulations

    Science.gov (United States)

    Çeçen, Yiğit; Yazgan, Çağrı

    2017-09-01

    Purpose. Nearly all Cobalt-60 teletherapy machines were removed around the world during the last two decades. The remaining ones are being used for experimental purposes. However, the rooms of these teletherapy machines are valuable because of lack of space in radiotherapy clinics. In order to place a new technology treatment machine in one of these rooms, one should re-shield the room since it was designed only for 1.25 MeV gamma beams on average. Mostly, the vendor of the new machine constructs the new shielding of the room using their experience. However, every radiotherapy room has different surrounding work areas and it would be wise to shield the room considering these special conditions. Also, the shield design goal of the clinic may be much lower than the International Atomic Energy Agency (IAEA) or the local association accepts. The study shows re-shielding of a Cobalt-60 room, specific to the clinic, using Monte Carlo simulations. Materials & Methods: First, a 6 MV Tomotherapy machine, then a 10 MV conventional linear accelerator (LINAC) was placed inside the Cobalt-60 teletherapy room. The photon flux outside the room was simulated using Monte Carlo N-Particle (MCNP6.1) code before and after re-shielding. For the Tomotherapy simulation, flux distributions around the machine were obtained from the vendor and implemented as the source of the model. The LINAC model was more generic with the 10 MeV electron source, the tungsten target, first and secondary collimators. The aim of the model was to obtain the maximum (40x40 cm2) open field at the isocenter. Two different simulations were carried out for gantry angles 90o and 270o. The LINAC was placed in the room such that the primary walls were A' (Gantry 270o) and C' (Gantry 90o) (figure 1). The second part of the study was to model the re-shielding of the room for Tomotherapy and for the conventional LINAC, separately. The aim was to investigate the recommended shielding by the vendors. Left side of the room

  4. Studied by electron paramagnetic resonance (EPR) of polymethyl methacrylate (PMMA) irradiated with gamma photons from cobalt 60

    International Nuclear Information System (INIS)

    Jalali, Hajer

    2013-01-01

    Ionizing radiation is radiation able to deposit enough energy in the material through which they pass to create ionization. These ionizing radiations, when mastered, have many practical uses beneficial (areas of health, industry ...). Gamma rays are emitted by radioactive nuclei. The objective of our work is the study of polymethyl methacrylate (PMMA) irradiated by gamma photons from cobalt-60. To study the technique of radio spectroscopy (9 to 10Hz) electron paramagnetic resonance EPR is used. This technique is specific to characterize transient free radicals involved in chemical reactions such as oxidation, combustion, polymerization reactions ... We analyzed the EPR spectra three batch KS, EB, and JF our dosimeter according to the dose (high and low) and showed that the dosimetric response can be represented in exponential form (high dose) and linear form (low dose). We also studied the kinetics of decay of the EPR signal as a function of time (fading) and showed that the responses relating to stabilize after 20 min of irradiation.

  5. Sci-Thur PM – Brachytherapy 04: Commissioning and Implementation of a Cobalt-60 High Dose Rate Brachytherapy Source

    Energy Technology Data Exchange (ETDEWEB)

    Dysart, Jonathan [Horizon Health Network (Canada)

    2016-08-15

    An Eckert & Ziegler Bebig Co0.A86 cobalt 60 high dose rate (HDR) brachytherapy source was commissioned for clinical use. Long-lived Co-60 HDR sources offer potential logistical and economic advantages over Ir-192 sources, and should be considered for low to medium workload brachytherapy departments where modest increases in treatment times are not a factor. In optimized plans, the Co-60 source provides a similar dose distribution to Ir-192 despite the difference in radiation energy. By switching to Co-60, source exchange frequency can be reduced by a factor of 20, resulting in overall financial savings of more than 50% compared to Ir-192 sources. In addition, a reduction in Physicist QA workload of roughly 200 hours over the 5 year life of the Co-60 source is also expected. These benefits should be considered against the modest increases in average treatment time compared to those of Ir-192 sources, as well as the centre-specific needs for operating room shielding modification.

  6. Design and Simulation of 5-DOF Vision-Based Manipulator to Increase Radiation Safety for Industrial Cobalt-60 Irradiators

    International Nuclear Information System (INIS)

    Solyman, A.E.; Keshk, A.B.; Sharshar, K.A.; Roman, M.R.

    2016-01-01

    Robotics has proved its efficiency in nuclear and radiation fields. Computer vision is one of the advanced approaches used to enhance robotic efficiency. The current work investigates the possibility of using a vision-based controlled arm robot to collect the fallen hot Cobalt-60 capsules inside wet storage pool of industrial irradiator. A 5-DOF arm robot is designed and vision algorithms are established to pick the fallen capsules on the bottom surface of the storage pool, read the information printed on its edge (cap) and move it to a safe storage place. Two object detection approaches are studied; RGB-based filter and background subtraction technique. Vision algorithms and camera calibration are done using MATLAB/SIMULINK program. Robot arm forward and inverse kinematics are developed and programmed using an embedded micro controller system. Experiments show the validity of the proposed system and prove its success. The collecting process will be done without interference of operators, hence radiation safety will be increased.

  7. Single institutional retrospective analysis: treatment of choroidal melanomas with cobalt-60 brachytherapy Análise retrospectiva uni-institucional: tratamento de melanomas de coróide com braquiterapia utilizando cobalto-60

    Directory of Open Access Journals (Sweden)

    Antônio Cássio Assis Pellizzon

    2004-06-01

    Full Text Available PURPOSE: To evaluate the outcome of patients with choroidal melanoma treated with conservative therapy with brachytherapy (episcleral Co-60 plaque therapy at the "Hospital do Cancer" São Paulo, Brazil. METHODS: We evaluated 102 patients consecutively treated from January, 1999 to June, 1999. Median age, maximum tumor base diameter and apex size were 55.5 years, 9.75 mm and 5 mm, respectively. Doses at the base of the tumor, including 1 mm of sclera, ranged from 157 to 487 Gy (median 284.5 Gy and to the apex from 37 to 220 Gy (median 106 Gy. RESULTS: The crude eye preservation rate with conservative therapy alone was 78.5%. Five-year overall actuarial survival rate was 92.2% and eye conservation rate was 78%. Side effects were mostly an uncomplicated retinopathy in 39/102 patients (38.2%; macular degeneration or scarring led to poor central vision in 31/102 patients (30.3% of cases. CONCLUSION: Our experience with cobalt-60 plaque brachytherapy achieved a satisfactory rate of local tumor control, despite the oversized base diameters of treated tumors.OBJETIVOS: Para avaliar o resultado de tratamento pacientes portadores de melanoma de coróide tratados com braquiterapia (placas episclerais de Co-60 no Hospital do Câncer, São Paulo, Brasil. MÉTODOS: Foram avaliados 108 pacientes tratados consecutivamente de janeiro de 1995 a junho de 1999, com idade mediana de 55,5 anos, diâmetro da base do tumor e altura máximos 9,75 mm e 5 mm, respectivamente. As doses na base do tumor, incluindo 1 mm de esclera variaram de 157 a 487 Gy (mediana 284,5 Gy e para o ápice de 37 até 220 Gy (mediana 106 Gy. RESULTADOS: A taxa de preservação ocular foi 78,5%, com sobrevida atuarial global em cinco anos, e a taxa de conservação ocular atuarial foram 92,2% e 78%, respectivamente. Os principais efeitos colaterais relacionados ao tratamento foram retinopatia em 39/102 (38,2% pacientes e degeneração macular, levando a déficit visual central em 31/102 (30

  8. Cobalt-60 and Caesium-137 Gamma Sources; Sources de rayonnement gamma au cobalt-60 et au cesium-137; Gamma-istochniki iz kobal'ta-605 i tseziya-137; Fuentes gamma de cobalto-60 y de cesio-137

    Energy Technology Data Exchange (ETDEWEB)

    Kulish, E E; Fradkin, G M [Academy of Sciences of the USSR, Moscow, Union of Soviet Socialits Republics (Russian Federation)

    1960-07-15

    The paper gives the main technical characteristics of gamma sources produced in the USSR using cobalt-60 and caesium-137 and discusses some of the problems of their production technology. The paper contains information on the radiation spectra of Co{sup 60} and Cs{sup 137} and of the source material from which they are prepared. Data are given on the dependence of the activity of cobalt sources upon the intensity of the neutron beam and the geometrical size of the sample. The yield of caesium by uranium fission is also analyzed. The problem of hermetic sealing of the sources is discussed and a complete nomenclature of all the sources manufactured in the USSR are listed, their size and activity also being indicated. In conclusion a comparison of Co{sup 60} and Cs{sup 137} sources is made. (author) [French] Cette communication expose les caracteristiques techniques fondamentales des sources de rayonnement gamma a base de cobalt-60 et de cesium-137 pro- duites en URSS; on y examine egalement certaines questions relatives a la technologie de leur production. La communication contient des donnees sur la nature du rayonnement des isotopes {sup 60}Co et {sup 137}Cs, ainsi que sur celle des matieres brutes utilisees pour leur preparation. On donne les resultats obtenus lors de l'etude de la variation de l'activite des sources au cobalt en fonction de la valeur du flux de neutrons et des dimensions geometriques de l'echantillon, ainsi que les resultats relatifs a la valeur du rendement en isotopes de cesium lors de la fission des noyaux d'uranium. On etudie ensuite les procedes pour assurer l'hermeticite de ces sources. Suit une nomenclature complete des sources produites en URSS, comportant des indications sur leurs dimensions geometriques et sur les valeurs de leur activite. Enfin, il est procede a une comparaison des sources au {sup 60}Co et au {sup 137}Cs. (author) [Spanish] En este informe se describen las principales caracteristicas tecnicas de las fuentes gamma de

  9. Use of low doses of cobalt 60 gamma radiation on beet (Beta vulgaris L.), carrot (Daucus carota L.) and radish (Raphanus sativus L.) seed to stimulate increase yield; Emprego da radiacao gama do cobalto 60 em sementes de beterraba (Beta vulgaris L.), cenoura (Daucus carota L.) e rabanete (Raphanus sativus L.) para estimular o aumento da producao

    Energy Technology Data Exchange (ETDEWEB)

    Bovi, Jose Eduardo

    2000-07-01

    The research had the aim of evaluating the effects of low doses of Cobalt-60 gamma radiation on seeds of radish (Raphanus sativus L.) cultiva Champion, cultivars Nantes Forto (european origin) and Brasilia (Rio Grande do Sul origin) carrot (Daucus carota L. var. sativus (Hoffm.) Thell), and red beet (Beta vulgaris L.) cultivar Tall Top Early Wonder before sowing, its effects on plant growth, on the yield and roots storage of two tillages: with sowing in the same day of radiation and six days after radiation seeds. The data showed that the seeds radiation did not interfered negatively on plants growth, and the species presented differences as roots production and doses on both plantation: radish with 5,0 Gy and 2,5 Gy doses respectively to the first and the second sowings, Brasilia carrot with 2,5 Gy dose to both sowings. Nantes carrot with 2,5 Gy and 5,0 Gy respectively to the first and the second sowings, and beet with 7,5 Gy and 5,0 Gy respectively to the first and the second plantations. There is not statistics difference by Tukey test (5% and 1%) and none relation between seeds radiation and loss weight on roots storage. (author)

  10. Determination of dosimetric parameters of Asymmetric fields from those of Symmetric fields for equinox 100 Cobalt-60 teletherapy machine

    International Nuclear Information System (INIS)

    Mensah, K.

    2014-07-01

    The Theratron Equinox 100 Cobalt-60 therapy unit is equipped wtih x-ray collimators or jaws that can be moved independently or allow asymmetric fields with field centres positioned away from the true central axis of the beam. Although asymmetric collimation can be performed by beam splitters or secondary blocking on a shadow tray; an independent jaw feature reduces the set-up time and spares the therapist from handling heavy blocks. Clinical sites where asymmetric jaws are typically used include breast, head and neck, craniospinal and prostate. Knowledge of the dose distribution of asymmetric fields is required to help evaluate the dosimetry of this non-standard treatment delivery technique prior to clinical implementation. IBA StarTrack 2-D array was used to acquire beam profiles of symmetric and asymmetric beams of different field sizes and varying depth using the Theratron Equinox 100 Cobalt-60 teletherapy unit. The 2-D water phantom was then used to measure PDDs and output factors of both the symmetric and asymmetric beams at varying depths and field sizes. The off-axis ratio was also determined from the half beam profile of the largest field size of the treatment machine and then the output factor ratios were used to validate it. The treatment planning system was then used to model both the symmetric and asymmetic beams and the PDDs and output factors were also calculated. Beam profiles for asymmetry beams showed good agreement with symmetry beam profiles for smaller field sizes and the deviations among them steadily became more evident with increasing field sizes. This difference in the dose distribution for asymmetric fields compared to the dose distribution for symmetric fields was due to the tilt of the dose profiles towards the beam axis. This tilt in the dose profiles of the asymmetic beams was caused by the oblique incidence of the asymmetric beam at off-axis locations, causing less beam hardening compared to that along the central axis. In treatment

  11. Experiences on the implementation of a postal auditing service to know teletherapy doses using Cobalt 60 attained by the Secondary laboratory for dosimetric calibration from CPHR

    International Nuclear Information System (INIS)

    Campa, R.; Morales, J.A.; Molina, D.; Dominguez, L.

    1998-01-01

    This paper analyzes experiences gained by LSCD from CPHR on the implementation and validation of a postal auditing system. The system checks doses absorbed by water for teletherapy equipment using Cobalt 60. The verification was made with Chinese DTL type JR 1152F (microbars) introduced in capsules developed and employed by IAEA in the postal auditing service for doses IAEA/WHO. The analysis includes the creation of groups of detectors based on their individual sensibility. They have a dispersion range that was almost 2%. Here irradiation was applied to a water dummy. Other tests employed were that for thermal treatment and calibration. Besides one auditing the effectiveness of the postal technique in two facilities using Cobalt 60. The methodology implemented helps to determine doses absorbed in reference conditions with a lower global uncertainty (k=2) (3.2%)

  12. Biological fate of cobalt-60 released during the corrosion of neutron-activated stanless steel in seawater

    International Nuclear Information System (INIS)

    Young, J.S.

    1982-03-01

    Passing seawater over radioactive Type 347 stainless steel in a sediment/seawater laboratory system and exposing marine animals to this environment provided information on the bioaccumulation of 60 Co from radioactive structural material. Exposure of marine organisms to radioactive corrosion products and directly to radioactive stainless steel in seawater simulated some of the possible conditions which could arise from the deposition of radioactive stainless steel on the ocean floor. Detectable levels of 60 Co in marine animals were not observed on a short term basis (5 weeks). Longterm (13 months) exposure of marine animals in a sediment/seawater system resulted in 60 Co bioaccumulation. The specific activity of 60 Co in the organisms was as much as one million times less than that initially present in the radioactive stainless steel. This was due to the dilution of 60 Co by stable cobalt in the seawater, sediments and organisms. As expected the 60 Co specific activity of the organisms never increased above that of the radioactive source. This is because 60 Co is chemicaly indistinguishable from stable Co. Increasing 60 Co concentration factors with decreasing 60 Co concentrations in the seawater and sediment media coupled with relatively constant 60 Co specific activities suggest a possible homeostatic control of cobalt concentrations in certain marine organisms. The evidence indicates that the marine animals derived more of the accumulated 60 Co from the sediments and interstitial water than from seawater. Cobalt-60 concentration factors were generally found to be lower than published cobalt concentration factors due to the predominantly insoluble nature of the corrosion products. Baseline information is provided on trace element concentrations in deep-sea organisms. Stable Co and twenty other elements were measured in abyssal invertebrates and a fish

  13. Dosimetry characterization of the Tunisian Cobalt-60 gamma irradiation pilot plant for the irradiation of the mediterranean fruit fly

    International Nuclear Information System (INIS)

    Bettaieb, Nasreddine; Farah, Kaled; Kadri, Omrane; Jerbi, Taieb; Gharbi, Foued; Manai, Kais

    2005-01-01

    Cobalt-60 gamma irradiation pilot plant has been put into operation in 1999 at the National Center for nuclear scinces and technologies, Sidi-Thabet, Tunisia. An initial characterization of this pilot was performed to determine the overall performance of the irradiator in delivering absorbed dose to a product prior to routine processing, in particular sterilisation of medical devices and food irradiation. A new irradiation holder was recently installed; it was designed especially for the irradiation of pupae of the Meditterranean fruit fly. It consists of four turn plates which makes it possible to rotate the canisters holding the pupae within the radiation field. The axis of ratation is vertical and parallel to the source pencils. Prior to routine irradiation using the new irradiation holder, validation procedures are necessary to establish conditions of the irradiation within the specification. In the course of these procedures, detailed dose mapping on a vertical plane in the middel of the canister of insect pupae with bulk density of 0.446 g /cm3 was carried out for two irradiation configurations : fixed plates and turned plates. GafChromic dosimeter calibrated against Alanine / ESR dosimetry system was used for the dose measurements. The maximum and minimum dose locations were determined and the dose uniformity ratio calculated and discussed. Detailed analyses of the isodose curves and histogram of the frequency distribution of absorbed dose were also given. Transit dose and dose rate in the reference position inside the canister were measured using Fricke dosimeters. The results of measurements of absorbed dose and dose distribution in insect pupae do not show any significant difference in the dose uniformity ratio (U=Dmax / Dmin) between the two irradiation configurations. At the same time we observed with turned plates configuration an improvement of the homogeneity of the absorbed dose distribution in the insect pupae showed by the increasing of the pipae

  14. Uptake of cobalt-60 from sea water and from labelled food by the common shrimp Crangon erangon (L.)

    International Nuclear Information System (INIS)

    Weers, A.W. van

    1975-01-01

    The role of two different modes of uptake in the accumulation of 60 Co by the common shrimp (Crangon crangon (L.)) is the subject of the present study. The results show that accumulation of 60 Co from sea water is a slow process. The concentration factor for whole animals reached in one month was only about 13. Most of the activity accumulated from water appears to be associated with the exoskeleton. As a consequence, moulting has a pronounced effect on the uptake pattern of 60 Co and on the subsequent retention of the radionuclide by shrimps kept in non-radioactive sea water. After single feeding of shrimps with labelled mussel flesh, 60 Co is retained according to an exponential function with a short-lived and a long-lived component. The short-lived component has a mean biological half-life of 1.2 days and accounts for about 80% of the initial activity. About 20% of the initial activity is lost with a mean biological half-life of about 10 days. After repeated feeding of labelled mussel flesh the short-lived component in the 60 Co retention is virtually absent. Cobalt-60 taken up with food is localized mainly in the digestive gland and the concentration in the edible muscles from the abdomen is relatively small. It is concluded from the present study that direct uptake from sea water will play only a minor role in the accumulation of 60 Co in the internal organs of the shrimp. 60 Co released into the marine environment will be taken up by shrimps mainly from food. The results indicate a rapid turnover of 60 Co in shrimps. (author)

  15. Radioprotective activity of curcumin-encapsulated liposomes against genotoxicity caused by Gamma Cobalt-60 irradiation in human blood cells.

    Science.gov (United States)

    Nguyen, Minh-Hiep; Pham, Ngoc-Duy; Dong, Bingxue; Nguyen, Thi-Huynh-Nga; Bui, Chi-Bao; Hadinoto, Kunn

    2017-11-01

    While the radioprotective activity of curcumin against genotoxicity has been well established, its poor oral bioavailability has limited its successful clinical applications. Nanoscale formulations, including liposomes, have been demonstrated to improve curcumin bioavailability. The objective of the present work was (1) to prepare and characterize curcumin-encapsulated liposomes (i.e. size, colloidal stability, encapsulation efficiency, and payload), and (2) subsequently to evaluate their radioprotective activity against genotoxicity in human blood cells caused by Gamma Cobalt-60 irradiation. The curcumin-encapsulated liposomes were prepared by lipid-film hydration method using commercial phosphatidylcholine (i.e. Phospholipon ® 90G). The blood cells were obtained from healthy male donors (n = 3) under an approved ethics protocol. The cell uptake and the radioprotective activity of the curcumin-encapsulated liposomes were characterized by fluorescence microscopy and micronucleus assay, respectively. Nanoscale curcumin-encapsulated liposomes exhibiting good physical characteristics and successful uptake by the human blood cells were successfully prepared. The radioprotective activity of the curcumin-encapsulated liposomes was found to be dependent on the curcumin concentration, where an optimal concentration existed (i.e. 30 μg/mL) independent of the irradiation dose, above which the radioprotective activity had become stagnant (i.e. no more reduction in the micronuclei frequency). The present results established for the first time the radioprotective activity of curcumin-encapsulated liposomes in human blood cells, which coupled by its well-established bioavailability, boded well for its potential application as a nanoscale delivery system of other radioprotective phytochemicals.

  16. Effects of cobalt-60 gamma radiation on the strength-related internal structure of the borosilicate glass

    International Nuclear Information System (INIS)

    Cafe, Arven I.; Liamzon, Angelie J.

    2011-03-01

    Borosilicate glass in the form of glass slides (1.Omm in thickness and cut into 12.5mm x 55.Omm surface area) was examined to determine the reusability or recyclability and strength of glass apparatuses or compartments after exposing to gamma irradiation from Co-60 source. After knowing the initial parameters using EDXRF under six secondary targets, glass specimens prepared was subjected to gamma radiation for doses 3kGy, 6kGy, 15kGy, 25kGy, and 100kGy. Results of characterization under FTIR provides information about the occurred extension of B-O-Si and B-O-B linkages for lower doses (3-25kGy), while destruction of Si-O bonds for higher dose (100kGy). It shows direct relationship on the observed color change from clear ransparent to deep brown corresponding to the change in optical densities as irradiation dose increases. Ability to fade the induced deep brown color was also observed for a certain time interval which satisfies that this type of glass exhibits self healing property. Although, average energy of about 1.25MeV causes rearrangement of atoms within the glass, according to the XRD result, it remained to be an amorphous solid even in higher dose applied which satisfies that remanufacturing and recycling is possible. (author)

  17. Disinfestation of apples attacked by the fruit fly Anastrepha fraterculus (Wied.) (Diptera: Tephritidae) using gamma radiation of cobalt-60

    International Nuclear Information System (INIS)

    Arthur, Valter; Wiendl, Frederico M.

    1996-01-01

    Apples, cv. Gala, artificially infested during 72 hours with adults of the fruit fly Anastrepha fraterculus (Wied.) were irradiated with the following gamma radiation doses: 0 (control), 25, 50, 75 and 100 Gy, at the dose rate of 1048 Gy per hour. After irradiation fruits were put in plastic bags with 80 ml of sugar cane bagasse. The bags were maintained in a rearing room at temperature 21 - 24 deg C, 65 - 75% R H, and photo period of 12 hours. Pupae obtained were sieved out and kept in small glass tubes. All doses tested did not allow emergence of adults. (author)

  18. PENGARUH RADIASI SINAR GAMMA COBALT-60 TERHADAP SIFAT MORFOLOGI DAN AGRONOMI KETIGA VARIETAS JAGUNG (ZEA MAYS L.

    Directory of Open Access Journals (Sweden)

    Makhziah

    2017-04-01

    Full Text Available Mutation is one of the ways to improve genetic variation in plant breeding so the target traits were more easily obtained. Grains of three varieties of maize (Bisma, Madura local, and Gumarang were treated with gamma 60cobalt irradiation doses (0, 100, 200, and 300 Gy before sowing then planted in a split plot randomized block design with three replication, to be evaluated for their morphology and agronomic traits. The Main plot was cultivars and sub plot was gamma radiation rates. There was no interaction between gamma rates and cultivars of maize, but increasing of gamma rates caused decreasing of some traits. Some traits such as plant height and leaves number were decreased significantly when gamma rate increased 100 to 300 Gy as well yield components such as grain weight and grain number per ear. Gamma 200 caused produce more ears than other rates. Bisma exhibited greater performance than Madura and Gumarang both of morphology and agronomic traits.

  19. Development of the irradiation facility SIBO INRA/Tangier, Morocco by upgrading cobalt-60 in a temporary pool and enhancing safety and control features

    Directory of Open Access Journals (Sweden)

    Mohammed Mouhib

    2017-12-01

    Full Text Available An automatic control system is one of the most important parts of an irradiation facility. The level of this control is always maintained to comply with safety procedures during routine work in this field. Also sometimes it is limited to the minimum level of regulation required due to economical aspects; some commercial systems are generally made by manufacturers of industrial facilities and considered affordable by irradiators. In some cases specific irradiation facilities tailor their control systems to their needs. For this kind of irradiator the control system can be developed and upgraded according to personal and industrial experiences. These upgrading procedures are also used by others to develop their systems. The objective of this paper is to share a local experience in upgrading security, safety systems and the use of cobalt-60 for the irradiator. It is a composite experiment at SIBO INRA/Tangier, Morocco and concerns the: (i upgrade of cobalt-60 in a temporary pool in the SIBO irradiator in Tangier. This operation was conducted in collaboration with the International Atomic Energy Agency (IAEA and was a success story of 2014 according to the general conference of IAEA; (ii safety and technical upgrade of the system in the SIBO irradiator made in collaboration with IAEA; (iii installation and upgrade of the security system in accordance with the Global Threat Reduction Programme (GTRP to reduce the threat of a Radiological Dispersal Device (RDD in collaboration with The United States Department of Energy’s National Nuclear Security Administration (NNSA.

  20. Thermoluminescence characteristics of Cu2O doped Calcium Lithium borate glass irradiated with the cobalt-60 gamma rays

    International Nuclear Information System (INIS)

    Rammadhan, Ismail; Taha, Saddon; Wagiran, H.

    2017-01-01

    The aim of this study is to prepare and investigate the thermoluminescence characteristics for the un-doped and Cu 2 O doped calcium lithium borate glass upon adding various Cu 2 O concentrations of 0.005% to 0.1 mol%. The glasses were prepared by melt quenching method and irradiated with 60 CO gamma-ray having different doses in the range of (0.5–4) Gy, (5–10) Gy, and (20–100) Gy. The amorphous phases were identified for optimization glass samples, effect of heating rate, glowing curves, linearity, sensitivity, fading, reproducibility of response and minimum detectable dose are also studied. The TL sample with 0.02 mol% Cu 2 O concentration has higher response compared to the other samples concentration for a delivered dose of 50 Gy, The recorded glow curves consist a dominant peak at 187 °C for a heating rate of 5 °C s −1 . However, the value of effective atomic number Z eff is 8.84 for 0.02Cu 2 O doped which are near to the atomic number of soft tissue. - Highlights: •We have prepared and investigate the crystalline structure for the un-doped and Cu 2 O doped calcium lithium borate glass are carried out. •Investigate the amorphous structure of calcium lithium borate glass. •Determine the best setting of annealing temperature, annealing time and heating rate for Cu 2 O doped calcium lithium borate glass. •The doping effects of Cu 2 O on the thermoluminescence properties of calcium lithium borate glass subjected gamma radiations. •The new dosimeter showed simple glow curve with single prominent peak centred at 187 °C and linear dose–response range 0.5–100 Gy, good reproducibility, the fading of the signal is relatively slow. •Effective atomic number for Cu 2 O doped Calcium lithium borate close to the effective atomic number of soft tissue.

  1. Thermoluminescence characteristics of Cu{sub 2}O doped Calcium Lithium borate glass irradiated with the cobalt-60 gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Rammadhan, Ismail, E-mail: ismail.rammadhan@koyauniversity.org [Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor (Malaysia); Department of Physics, Faculty of Sciences and Health, Koya University, Danielle Mitterrand Boulevard, Koya 45, Kurdistan Region (Iraq); Taha, Saddon [Department of Physics, Faculty of Sciences and Health, Koya University, Danielle Mitterrand Boulevard, Koya 45, Kurdistan Region (Iraq); Wagiran, H. [Department of Physics, Universiti Teknologi Malaysia, 81310 Skudai, Johor (Malaysia)

    2017-06-15

    The aim of this study is to prepare and investigate the thermoluminescence characteristics for the un-doped and Cu{sub 2}O doped calcium lithium borate glass upon adding various Cu{sub 2}O concentrations of 0.005% to 0.1 mol%. The glasses were prepared by melt quenching method and irradiated with {sup 60}CO gamma-ray having different doses in the range of (0.5–4) Gy, (5–10) Gy, and (20–100) Gy. The amorphous phases were identified for optimization glass samples, effect of heating rate, glowing curves, linearity, sensitivity, fading, reproducibility of response and minimum detectable dose are also studied. The TL sample with 0.02 mol% Cu{sub 2}O concentration has higher response compared to the other samples concentration for a delivered dose of 50 Gy, The recorded glow curves consist a dominant peak at 187 °C for a heating rate of 5 °C s{sup −1}. However, the value of effective atomic number Z{sub eff} is 8.84 for 0.02Cu{sub 2}O doped which are near to the atomic number of soft tissue. - Highlights: •We have prepared and investigate the crystalline structure for the un-doped and Cu{sub 2}O doped calcium lithium borate glass are carried out. •Investigate the amorphous structure of calcium lithium borate glass. •Determine the best setting of annealing temperature, annealing time and heating rate for Cu{sub 2}O doped calcium lithium borate glass. •The doping effects of Cu{sub 2}O on the thermoluminescence properties of calcium lithium borate glass subjected gamma radiations. •The new dosimeter showed simple glow curve with single prominent peak centred at 187 °C and linear dose–response range 0.5–100 Gy, good reproducibility, the fading of the signal is relatively slow. •Effective atomic number for Cu{sub 2}O doped Calcium lithium borate close to the effective atomic number of soft tissue.

  2. The use of apoptosis in human lymphocytes peripheral as alternative methods in biological dosimetry of radiation effects from cobalt-60

    International Nuclear Information System (INIS)

    Lemes, Marisa

    1997-01-01

    Gamma rays affect cells in dose-response manner, resulting in cell death, as in cancer radiotherapy. The ionizing radiation acts by transferring energy, mainly by free radicals from water radiolysis that result in nucleic acid damage and other effects in lipids and proteins, The level of exposure is indirectly estimated by physical dosimetry, but the biological dosimetry can measure the direct radiation effect, mainly in post-dividing cells by classical cytogenetic approach. Recently, it was reported that irradiated cells develop an induced programmed death or apoptosis. With a biological dosimetric technique, we measured apoptotic cell fraction in 60 Co in vitro irradiated blood cells from voluntary healthy donors. The agarose gel electrophoresis showed a low sensitivity, because cell DNA presented the characteristic pattern only when the cells were exposed to 100 c Gy or more. Using a terminal DNA labeling technique we observed that the apoptotic cell fraction proportionally increases with irradiation. Similar sensitivity was observed when compared to classical cytogenetics (3 c Gy minimum detection level). These techniques are easier to perform, do not need cell culture and all cells, including interphase ones, can be analyzed, providing a good tool in biological dosimetry. (author)

  3. Application gamma radiation of cobalt-60 in disinfestation of some types of rations for feeding small animals

    International Nuclear Information System (INIS)

    Arthur, Paula Bergamin

    2012-01-01

    The pests as beetles, mites, moths and mushrooms among other, usually infest products stored as: grains, crumbs, flours, coffee, tobacco, dried fruits, animal rations, spices, dehydrated plants, causing the visual depreciation and promoting to deterioration of the products. The present research had as objective the use of the gamma radiation in the disinfestation of some types of rations used for feeding animals of small size. In the first experiment packing of free samples were used measuring 10 cm x 20 cm with capacity of 70 grams of substrate (ration) with 4 types of existent marks in the trade: (1), (2), e (3), and (4). Each treatment consisted of 10 repetitions, that were irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy, to do the disinfestation of the samples. After the irradiation (disinfestation) of the all irradiated packing and more the control was conditioned in plastic boxes of 80 cm x 50 cm with cover, where the insects were liberated Lasioderma serricorne, Plodia interpuctella, Sitophilus zeamais and Sitophilus oryzae, in a total of 400 for each box and maintained at room acclimatized with 27 ± 2 Deg C and relative humidity of 70 ± 5%. In the second experiment packing were used made with the materials of packing of the first experiment. Each packing was made of 10 cm x 15 cm, with capacity of 30 grams of substrate (ration). In each repetition was inoculated 10 insects of each species, in a total of 400 insects for experiment per box. The packing with substrate and insect, were stamped in commercial machine and irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy. The irradiated packing and the control were maintained at room acclimatized same the mentioned in the first experiment. The counting of the number of insects and holes in the packing were made after 60 days. Concluded that only the packing of the ration type number 4 was susceptive to attack of all species of insects. The dose of 0,5 kGy was sufficient to induce the

  4. The use of Gamma radiation of Cobalt-60 to control avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit of Persea americana (Miller) (Lauraceae).; Uso da radiacao gama do Cobalto-60, para controlar a broca-do-abacate Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) e seus efeitos na qualidade do fruto de Persea americana (Miller) (Lauraceae)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Lilian Karla Figueira da

    2004-07-01

    This work aimed to evaluate the influence of Gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit Persea americana (Miller) (Lauraceae). For this research, insects were irradiated in ali phases of their life cycle with doses varying from O to 600 Gy and they were maintained at the temperature of 25 +- 2 deg C, humidity of 70 +- 10% and photo phase of 14 h. The species was raised on natural diet, avocado seeds. The cultivar fruits Geada were irradiated with doses that varied from 0 to 150 Gy, maintained for 15 days at room temperature (20 a 35 deg C and humidity of 70 - 80 %) and 30 days at a temperature of 10 deg C, humidity of 40 - 60 %. The chemical-physics and sensorial analyses were carried out. According to the obtained results, it was verified that the lethal dose of gamma radiation to S. catenifer eggs, was of 75 Gy; for caterpillars and pupas was of 300 Gy. The sterile-dose for upcoming adults from irradiated S. catenifer eggs was of 25 Gy; for upcoming adults from irradiated caterpillars, it was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The irradiation in the avocado fruit, maintained at room temperature for 7 days of storage, caused change in the coloration of the fruit (dark spots and yellowish coloration) and more firmness. The sensorial characteristics were kept and the irradiated fruit was the chosen one as favorite for tasting. The irradiated fruits that were kept at 10 deg C, obtained an increase in the storage period, without changing their chemical physics characteristics. The coloration of the fruits was kept, more firmness and a subtle acidity taste increase, being effective in the conservation of the fruits and in the maintenance of their sensorial characteristics. The use of the gamma radiation as treatment quarantine of S. catenifer it was efficient, should be treated them with

  5. Main aspects in licensing of a type B(U) package design for the transport of 12.95 PBq of cobalt 60

    International Nuclear Information System (INIS)

    Lopez Vietri, J.R.; Novo, R.G.; Bianchi, A.J.

    1995-01-01

    This paper points out the relevant technical issues related to the licensing process, of a type B(U) package design, with cylindrical form and 9.3 ton mass, approved by the Argentine Competent Authority for the transport of 12.95 PBq of cobalt 60 as special form radioactive material. It is briefly described the heat transfer analysis, the structural performance under impulsive loads and the shielding calculation under both normal and accidental conditions of transport, as well as the comparative analysis of the results obtained from design, pre-operational tests and independent evaluation performed by the Argentine Competent Authority to verify the compliance with the Regulations for the Safe Transport of Radioactive Material of the International Atomic Energy Agency. (author). 14 refs., 1 fig., tabs

  6. SU-C-BRC-01: A Monte Carlo Study of Out-Of-Field Doses From Cobalt-60 Teletherapy Units Intended for Historical Correlations of Dose to Normal Tissue

    Energy Technology Data Exchange (ETDEWEB)

    Petroccia, H [University of Florida, Gainesville, FL (United States); Olguin, E [Gainesville, FL (United States); Culberson, W [University of Wisconsin Madison, Madison, WI (United States); Bednarz, B [University of Wisconsin, Madison, WI (United States); Mendenhall, N [UF Health Proton Therapy Institute, Jacksonville, FL (United States); Bolch, W [University Florida, Gainesville, FL (United States)

    2016-06-15

    Purpose: Innovations in radiotherapy treatments, such as dynamic IMRT, VMAT, and SBRT/SRS, result in larger proportions of low-dose regions where normal tissues are exposed to low doses levels. Low doses of radiation have been linked to secondary cancers and cardiac toxicities. The AAPM TG Committee No.158 entitled, ‘Measurements and Calculations of Doses outside the Treatment Volume from External-Beam Radiation Therapy’, has been formed to review the dosimetry of non-target and out-of-field exposures using experimental and computational approaches. Studies on historical patients can provide comprehensive information about secondary effects from out-of-field doses when combined with long-term patient follow-up, thus providing significant insight into projecting future outcomes of patients undergoing modern-day treatments. Methods: We present a Monte Carlo model of a Theratron-1000 cobalt-60 teletherapy unit, which historically treated patients at the University of Florida, as a means of determining doses located outside the primary beam. Experimental data for a similar Theratron-1000 was obtained at the University of Wisconsin’s ADCL to benchmark the model for out-of-field dosimetry. An Exradin A12 ion chamber and TLD100 chips were used to measure doses in an extended water phantom to 60 cm outside the primary field at 5 and 10 cm depths. Results: Comparison between simulated and experimental measurements of PDDs and lateral profiles show good agreement for in-field and out-of-field doses. At 10 cm away from the edge of a 6×6, 10×10, and 20×20 cm2 field, relative out-of-field doses were measured in the range of 0.5% to 3% of the dose measured at 5 cm depth along the CAX. Conclusion: Out-of-field doses can be as high as 90 to 180 cGy assuming historical prescription doses of 30 to 60 Gy and should be considered when correlating late effects with normal tissue dose.

  7. A Modified Design for the Eastern Radiation Canyon for Cobalt60 Irradiator Maintain Attachment For Research and Production

    International Nuclear Information System (INIS)

    Keshk, A.B.; Ashour, M.A.; Imam, M.M.

    2003-01-01

    About 160 industrial radiation facilities using Co 60 are currently in operation in about 45 countries, many of them in developing countries. Most of these facilities are used for sterilization of medical products and pharmaceuticals, with a small number being used for processing of food items. The total installed capacity for processing of medical products at 20-25 k.Gy is about one million ton annually. There is a need to make some modifications on the design of these radiation canyons to allow radiation research, during mass production. By designing a new track for experimental research which can pass inside and outside radiation canyon through a special maze (labyrinth). The research samples will be put in two boxes out side the research door and they will go inside the canyon through research maze and stopped behind the products cars on two position, facing the source rack which will be in radiation position. The boxes will return back after finishing the exposure period

  8. Dosimetric intercomparison in Cobalt 60 unities using TLD-100 crystals and CaSO{sub 4}: Dy + Ptfe; Intercomparacion dosimetrica en unidades de cobalto 60 usando cristales de TLD-100 y CaSO{sub 4}: Dy + PTFE

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E. [Universidad Autonoma Metropolitana Xochimilco, Mexico D.F. (Mexico); Azorin N, J. [Universidad Autonoma Metropolitana Iztapalapa, Mexico D.F. (Mexico); Perez P, M.A. [Instituto Nacional de Cancerologia, Mexico D.F. (Mexico); Castillo H, M. [Centro Medico Nacional 20 de Noviembre, ISSSTE, Mexico D.F. (Mexico); Flores F, F. [Unidad de Oncologia, Centro Medico Nacional, IMSS, Mexico D.F. (Mexico); Guzman R, L.V. [Unidad de Oncologia, Hospital General de Mexico, Mexico D.F. (Mexico)

    1999-07-01

    The purpose of this work is to design and construct a phantom in basis of thermoplastic polymer of methyl methacrylate that is reutilizable and which allows to do an analysis of the absorbed doses in thermoluminescent crystals (Tl) exposed to cobalt 60 to establish the dosimetric intercomparison in cobalt units which allows to do the follow-up of the Quality assurance programs, standardization of calibration procedures, dosimetry and TLD post intercomparison in radiotherapy. This work allows also prove new thermoluminescent materials of national manufacture developed by Juan Azorin and collaborators as the CaSO{sub 4}: Dy + Ptfe. This is a first study which is realized in Mexico with the system crystal-phantom for aims to intercomparison in cobalt 60 units. In this work participate eight unities of cobalt 60 of different trades belonging at four radiotherapy centers. The results of the dose intercomparison of the eight unities of cobalt 60 were in the range 0.95-1.13, taking in account that the values between 0.95 and 1.05 were considered acceptable in terms of the requirements by the standing legislation. (Author)

  9. Estimation of uranium and cobalt-60 distribution coefficients and uranium-235 enrichment at the Combustion Engineering Company site in Windsor, Connecticut

    International Nuclear Information System (INIS)

    Wang, Y.; Orlandini, K.A.; Yu, C.

    1996-05-01

    Site-specific distribution coefficients for uranium isotopes and cobalt-60 (Co-60) and the fraction of uranium-235 (U-235) enrichment by mass were estimated for environmental samples collected from the Combustion Engineering Company site in Windsor, CT. This site has been identified for remedial action under the US Department of Energy's (DOE) Formerly Utilized Sites Remedial Action Program. The authority of DOE at the Combustion Engineering site is limited to (1) Building 3; (2) other activities or areas associated exclusively with Building 3 (such as sewer lines); or (3) contamination that is exclusively highly enriched uranium. In this study, 16 samples were collected from the Combustion Engineering site, including 8 soil, 4 sediment, 3 water, and 1 water plus sludge sample. These samples were analyzed for isotopic uranium by alpha spectrometry and for Co-60 by gamma spectrometry. The site-specific distribution coefficient for each isotope was estimated as the ratio of extractable radionuclide activity in the solid phase to the activity in the contact solution following a 19-day equilibration. The uranium activity measurements indicate that uranium-234 (U-234) and uranium-238 (U-238) were in secular equilibrium in two soil samples and that soil and sediment samples collected from other sampling locations had higher U-234 activity than U-238 activity in both the solid and solution phases. The site-specific distribution coefficient (Kd) ranged from 82 to 44,600 mL/g for U-238 and from 102 to 65,900 mL/g for U-234. Calculation of U-235 enrichment by mass indicated that four soil samples had values greater than 0.20; these values were 0.37, 0.38, 0.46, and 0.68. Cobalt-60 activity was detected in only three sediment samples. The measured Co-60 activity in the solid phase ranged from 0.15 to 0.45 pCi/g and that in the water phase of all three samples combined was 4 pCi/L. The Kd value for Co-60 in the site brook sediment was calculated to be 70 mL/g

  10. A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator–based stereotactic body radiotherapy for central early-stage non−small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Merna, Catherine; Rwigema, Jean-Claude M.; Cao, Minsong; Wang, Pin-Chieh; Kishan, Amar U.; Michailian, Argin; Lamb, James; Sheng, Ke; Agazaryan, Nzhde; Low, Daniel A.; Kupelian, Patrick; Steinberg, Michael L.; Lee, Percy, E-mail: percylee@mednet.ucla.edu

    2016-04-01

    We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non−small cell lung cancer with a tri-cobalt-60 (tri-{sup 60}Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)–based SBRT. In all, 20 patients with large central early-stage non−small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-{sup 60}Co system for a prescription dose of 50 Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R{sub 100} values were calculated as the total tissue volume receiving 100% of the dose (V{sub 100}) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-{sup 60}Co SBRT plans were performed using Student's t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3 cc (range: 12.1 to 139.4 cc). Of the tri-{sup 60}Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R{sub 100} values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-{sup 60}Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-{sup 60}Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while

  11. A treatment planning comparison between modulated tri-cobalt-60 teletherapy and linear accelerator-based stereotactic body radiotherapy for central early-stage non-small cell lung cancer.

    Science.gov (United States)

    Merna, Catherine; Rwigema, Jean-Claude M; Cao, Minsong; Wang, Pin-Chieh; Kishan, Amar U; Michailian, Argin; Lamb, James; Sheng, Ke; Agazaryan, Nzhde; Low, Daniel A; Kupelian, Patrick; Steinberg, Michael L; Lee, Percy

    2016-01-01

    We evaluated the feasibility of planning stereotactic body radiotherapy (SBRT) for large central early-stage non-small cell lung cancer with a tri-cobalt-60 (tri-(60)Co) system equipped with real-time magnetic resonance imaging (MRI) guidance, as compared to linear accelerator (LINAC)-based SBRT. In all, 20 patients with large central early-stage non-small cell lung cancer who were treated between 2010 and 2015 with LINAC-based SBRT were replanned using a tri-(60)Co system for a prescription dose of 50Gy in 4 fractions. Doses to organs at risk were evaluated based on established MD Anderson constraints for central lung SBRT. R100 values were calculated as the total tissue volume receiving 100% of the dose (V100) divided by the planning target volume and compared to assess dose conformity. Dosimetric comparisons between LINAC-based and tri-(60)Co SBRT plans were performed using Student׳s t-test and Wilcoxon Ranks test. Blinded reviews by radiation oncologists were performed to assess the suitability of both plans for clinical delivery. The mean planning target volume was 48.3cc (range: 12.1 to 139.4cc). Of the tri-(60)Co SBRT plans, a mean 97.4% of dosimetric parameters per patient met MD Anderson dose constraints, whereas a mean 98.8% of dosimetric parameters per patient were met with LINAC-based SBRT planning (p = 0.056). R100 values were similar between both plans (1.20 vs 1.21, p = 0.79). Upon blinded review by 4 radiation oncologists, an average of 90% of the tri-(60)Co SBRT plans were considered acceptable for clinical delivery compared with 100% of the corresponding LINAC-based SBRT plans (p = 0.17). SBRT planning using the tri-(60)Co system with built-in MRI is feasible and achieves clinically acceptable plans for most central lung patients, with similar target dose conformity and organ at risk dosimetry. The added benefit of real-time MRI-guided therapy may further optimize tumor targeting while improving normal tissue sparing, which warrants further

  12. Use of gamma radiation of Cobalt-60 aiming at the quarentenary treatment and the sterilization of Stenoma catenifer Walsingham (Lepidoptera: Elachistidae); Uso de radiación gamma de Cobalto-60 en tratamiento cuarentenario y esterilización de Stenoma catenifer Walsingham (Lepidoptera: Elachistidae)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, L. K.F.; Arthur, V.; Nava, D. E.; Parra, J. R.P.

    2007-07-15

    The objective of this work was verify the influence of gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham (Lepidoptera: Elachistidae). For this research, insects were irradiated in all phases of their life cycle with doses varying from 0 to 600 Gy and they were maintained at the temperature of 25 +/- 2 deg C, relative humidity of 70 +/- 10% and photofase of 14 h. The species was reared on natural diet, avocado seeds, variety Breda. According to the obtained results, was verified that the lethal dose of gamma radiation to S. catenifer larvae and pupae was of 300 Gy. The sterile dose for upcoming adults from irradiated S. catenifer larvae, was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The use the gamma radiation as treatment quarentine of S. catenifer was efficient, should be treated them with doses able to promote the sterilization of insect, without committing your qualities physical-chemistries and sensorial of fruits. Therefore, is suggested the treatment with the dose of 50 Gy for fruits infested with eggs and 150 Gy for fruits infested with larvae and pupas of S. catenifer. For use the sterile insect technique is recommended the irradiation of pupas and adults with doses of 150 Gy and 200 Gy, respectively [Portuguese] O objetivo deste trabalho foi verificar a influência da radiação gama Cobalto-60, na broca-do-abacate, Stenoma catenifer Walsingham (Lepidoptera: Elachistidae) como subsídio a tratamentos quarentenários e para aplicação da técnica do inseto estéril. Para isso, foram irradiados insetos, em todas as fases do ciclo de vida, com doses que variaram de 0 a 600 Gy e mantidos à temperatura de 25 ± 2º C; umidade relativa de 70 ± 10% e fotofase de 14 h. A espécie, foi criada em dieta natural, ou seja, sementes de abacate, cultivar Breda. De acordo com os resultados obtidos, verificou-se que a dose letal de radiação gama para lagartas e pupas de S

  13. Louis Harold Gray (1905-1965)

    International Nuclear Information System (INIS)

    Tomljenovic, I.

    2003-01-01

    15th CGPM (Conference General de Poids et Mesures) conference of 1975 accepted gray (Gy) as the unit of absorbed dose in honour of British physicist and radiation biologist Louis Harold Gray. This unit is a part of the SI system for units and measures. The idea of the article is to give a closer look into the life and work of this great scientist. (author)

  14. Exemption from licensing requirements for spark-gap irradiators that contain cobalt-60: (Docket No. PRM 30-54): Draft environmental statement

    International Nuclear Information System (INIS)

    1975-09-01

    This Draft Statement on environmental considerations associated with the proposed exemption of cobalt-60 in spark-gap irradiators was prepared by the US Nuclear Regulatory Commission, Office of Standards Development (the staff), in accordance with the Commission's regulation 10 CFR Part 51, which implements the requirements of the National Environmental Policy Act of 1969 (NEPA). The NEPA states, among other things, that the federal government has the continuing responsibility to use all practicable means, consistent with other essential considerations of national policy, to improve and to coordinate federal plans, functions, programs, and resources to the end that the nation may: fulfill the responsibilities of each generation as trustee of the environment for succeeding generations; assure for all Americans safe, healthful, productive, and esthetically and culturally pleasing surroundings; attain the widest range of beneficial uses of the environment without degradation, risk to health or safety, or other undesirable and unintended consequences; preserve important historic, cultural, and natural aspects of our national heritage, and maintain, wherever possible, an environment which supports diversity and variety of individual choice; achieve a balance between population and resource use which will permit high standards of living and a wide sharing of life's amenities; and enhance the quality of renewable resources and approach the maximum attainable recycling of depletable resources. 42 refs., 5 figs., 7 tabs

  15. Preliminary study on the effect of cobalt-60 gamma radiation on the conservation of potato tubers for consumption (Solanum tuberosum l.), during the storage period

    International Nuclear Information System (INIS)

    Montepeque Roldan, R.

    1984-03-01

    The object of the thesis is the study of the inhibiting effect of the sprouting of potato tubers, variety Loman, after Cobalt-60 gamma irradiation (with doses of 4, 6, 8, 10 and 12 Krads) as well as after treatment with the chemical inhibitor Isopropyl-N-Phenyl Carbonate (IPC). These treatments were applied to different groups of tubers, after 15 and 45 days from harvesting, stored under two illumination conditions: darkness (closed room), and indirect light (straw hut). The number, length and thickness of the sprouts, as well as the weight, humidity contents and infection of the tubers were recorded twice a month. A random 2x2x7x4 multifactorial design, with 3 repetitions, was used for the analysis and interpretation of the results. Variance and multiple regression analysis, as well as Tukey tests were performed on the IBM/370 computer of the San Carlos University (Guatemala). It was found that both the 4 and 6 Krad doses and the IPC treatments have no effect on the sprouting inhibition. The irradiation with the 8, 10, and 12 Krad doses inhibited the sprouting in an irreversible way, with insignificant loss of weight and moisture, regardless of the irradiation epoch and light condition. However, the tubers stored in darkness, showed ideal characteristics for consumption, and the 8 Krad dose, applied at 15 days after harvesting is concluded to be the best

  16. Humoral response and neutralization capacity of sheep serum inoculated with natural and Cobalt 60-irradiated Crotalus durissus terrificus venom (Laurenti, 1768)

    International Nuclear Information System (INIS)

    Netto, D.P.; Alfieri, A.A.; Chiacchio, S.B.; Bicudo, P.L.; Nascimento, N.

    2002-01-01

    The aim of this work was to investigate antigen irradiation on crotalic antivenom and the capacity of sheep as serum producers. Twelve sheep in two groups of six were inoculated with Crotalus durissus terrificus venom. One group was inoculated with natural venom (N V) and the other with Cobalt 60 gamma-irradiated venom (Ir V). Three antigen doses were given to the animals at monthly intervals for immunization. The toxic activity of the venom was assessed by LD 50 determination in mice. Blood samples were collected weekly analyses of serum neutralization capacity and potency. At the end of the experiment, the animals were challenged with a LD 50 for sheep showed no signs of envenoming. These results showed that toxicity of the irradiated venom was 4.4 times less than the natural venom. The sera from the irradiated group neutralized LD 50 14.6 times, and the sera from the natural group 4.4 times. Sera from the irradiated group were five times more potent. The two groups did not present clinical alterations. The results of this study show the potential for using sheep in crotalic antivenom production. The use of irradiated venom in sheep immunization induces a powerful and lasting humoral immune response shown by both the in vitro neutralization and potency tests and by the indirect ELISA antibody level detection technique. (author)

  17. Cobalt-60 radiation leukemogenesis studies

    International Nuclear Information System (INIS)

    Kawakami, T.G.; Cain, G.R.; Taylor, N.J.; Shifrine, M.; Goldman, M.

    1985-01-01

    Canine myeloblastic leukemia cells are not metabolically a homogeneous population. Isotopic ( 3 H-thymidine) and immunofluorescent labelling of blastic leukemia cells for DNA synthesis indicated that active DNA synthesis occurred in small populations (10-30%) while the remaining cells were at maturation arrest. This characteristic of reduced DNA synthesis is common to granulocytic, monocytic and megakaryoblastic leukemia. Based on allo-transplantation studies, malignancy of leukemic cells is a constitutive property of the cells. A protein factor produced by the leukemic cell is responsible for maturation arrest. Based on SDS-polyacrylamide gel electrophoresis, the maturation arrest factor consist of several peptides. Long-term cultures of leukemic cells have been established. Molecular studies for malignant transformation are now underway. 3 figures, 2 tables

  18. High levels of stable p53 protein and the expression of c-myc in cultured human epithelial tissue after cobalt-60 irradiation

    International Nuclear Information System (INIS)

    Mothersill, C.; Seymour, C.B.; Harney, J.; Hennessy, T.P.

    1994-01-01

    When explants of human uroepithelium or esophageal epithelium are exposed to acute doses of radiation (cobalt-60), the cells which grow out to form the primary cultures show a number of abnormal features. These include the development of characteristic nonsenescent foci. These foci have previously been shown to be c-myc positive and to have an abnormal, tumor-like ultrastructure. Expression of c-myc and the level of stable p53 proteins have now been examined in these cultures 2 weeks after irradiation. Both proteins occurred in dividing cells at the growing edge of the explant and in the foci. The expression of c-myc appeared to be correlated with growth. As expected, variation between individual cultures of normal human cells was noted in the expression of stable p53 protein. Most control uroepithelial cell cultures were negative, but a small cohort showed a wide range of values. The control cultures from the esophageal tissues had high expression of p53, and this decreased marginally after irradiation. Cells positive for p53 were always in cycle and were usually positive for c-myc as well. It would appear from these results that the expression of c-myc and the stable form of the p53 protein occur in irradiated primary cultures of normal human cells both in foci which also express a number of abnormalities and in open-quotes edgeclose quotes cells which are dividing. Cultures of unirradiated cells from esophagus and a small number of uroepithelial samples had high levels of p53. Possible reasons for this are discussed. 33 refs., 2 figs., 3 tabs

  19. The justification for the use of table of equivalent squares with respect to reference depth total scatter factor, and phantom scatter factor, for cobalt-60 teletherapy

    International Nuclear Information System (INIS)

    Afari, F.

    2011-01-01

    The use of equivalent squares is of great value and importance when determining output and depth dose data for rectangular fields. The variation with field shape of collimator scatter factors (S c ), phantom scatter factors (S c,p ) were studied using measurements on GWGP 80 cobalt - 60 teletherapy machine at the National Centre of Radiotherapy and Nuclear Medicine in the Korle-Bu Teaching Hospital. Measurements of the collimator scatter factors (S c ), phantom scatter factors (S p ) and total scatter factors (S c, p) were made at the depth of 5 cm, 10 cm, 15 cm and 20 cm in full scatter water phantom for square field side and rectangular fields of varying dimensions. The measurements were done using the source - axis distance (Sad) technique. The values of total scatter factor (S c,p ), phantom scatter factor and collimator scatter factor (S c ) obtained were used to estimate equivalent squares for the rectangular fields at the various depths. The equivalent squares were computed using the method of interpolation which is based on the scatter analysis of these scatter factors and these estimated equivalent squares were then compared with equivalent squares were then compared with equivalent square fields from BJR (supplement 21) tables of equivalent squares. The research revealed that there were average deviation of 1.5% for smaller rectangular field sizes and 8.8% for elongated rectangular field sizes between the estimated square field sizes and the equivalent square field from BJR (supplement 21) Table of equivalent square fields. The 8.8% for the elongated rectangular fields is not accepted, though such fields are rarely used in our Hospitals. It was found that the values of the equivalent square at the various depth were very consistent and do not vary with reference depth. These findings confirm that the clinical use of the BJR (supplement 21) Table of equivalent squares for total scatter factors and phantom scatter related quantities of rectangular fields is

  20. Effects of single and split doses of cobalt-60 gamma rays and 14 MeV neutrons on mouse stem cell spermatogonia.

    Science.gov (United States)

    Hacker-Klom, U B; Köhnlein, W; Göhde, W

    2000-12-01

    The long-term effects of ionizing radiation on male gonads may be the result of damage to spermatogonial stem cells. Doses of 10 cGy to 15 Gy (60)Co gamma rays or 10 cGy to 7 Gy 14 MeV neutrons were given to NMRI mice as single or split doses separated by a 24-h interval. The ratios of haploid spermatids/2c cells and the coefficients of variation of DNA histogram peaks as measures of both the cytocidal and the clastogenic actions of radiation were analyzed by DNA flow cytometry after DAPI staining. The coefficient of variation is not only a statistical examination of the data but is also used here as a measure of residual damage to DNA (i.e. a biological dosimeter). Testicular histology was examined in parallel. At 70 days after irradiation, the relative biological effectiveness for neutrons at 50% survival of spermatogonial stem cells was 3.6 for single doses and 2.8 for split doses. The average coefficient of variation of unirradiated controls of elongated spermatids was doubled when stem cells were irradiated with single doses of approximately 14 Gy (60)Co gamma rays or 3 Gy neutrons and observed 70 days later. Split doses of (60)Co gamma rays were more effective than single doses, doubling DNA dispersion at 7 Gy. No fractionation effect was found with neutrons with coefficients of variation.

  1. The role of Cobalt-60 source in Intensity Modulated Radiation Therapy: From modeling finite sources to treatment planning and conformal dose delivery

    Science.gov (United States)

    Dhanesar, Sandeep Kaur

    Cobalt-60 (Co-60) units played an integral role in radiation therapy from the mid-1950s to the 1970s. Although they continue to be used to treat cancer in some parts of the world, their role has been significantly reduced due to the invention of medical linear accelerators. A number of groups have indicated a strong potential for Co-60 units in modern radiation therapy. The Medical Physics group at the Cancer Center of the Southeastern Ontario and Queen's University has shown the feasibility of Intensity Modulated Radiation Therapy (IMRT) via simple conformal treatment planning and dose delivery using a Co-60 unit. In this thesis, initial Co-60 tomotherapy planning investigations on simple uniform phantoms are extended to actual clinical cases based on patient CT data. The planning is based on radiation dose data from a clinical Co-60 unit fitted with a multileaf collimator (MLC) and modeled in the EGSnrc Monte Carlo system. An in house treatment planning program is used to calculate IMRT dose distributions. Conformal delivery in a single slice on a uniform phantom based on sequentially delivered pencil beams is verified by Gafchromic film. Volumetric dose distributions for Co-60 serial tomotherapy are then generated for typical clinical sites that had been treated at our clinic by conventional 6MV IMRT using Varian Eclipse treatment plans. The Co-60 treatment plans are compared with the clinical IMRT plans using conventional matrices such as dose volume histograms (DVH). Dose delivery based on simultaneously opened MLC leaves is also explored and a novel MLC segmentation method is proposed. In order to increase efficiency of dose calculations, a novel convolution based fluence model for treatment planning is also proposed. The ion chamber measurements showed that the Monte Carlo modeling of the beam data under the MIMiC MLC is accurate. The film measurements from the uniform phantom irradiations confirm that IMRT plans from our in-house treatment planning system

  2. Interaction of 2-Gy Equivalent Dose and Margin Status in Perioperative High-Dose-Rate Brachytherapy

    International Nuclear Information System (INIS)

    Martinez-Monge, Rafael; Cambeiro, Mauricio; Moreno, Marta; Gaztanaga, Miren; San Julian, Mikel; Alcalde, Juan; Jurado, Matias

    2011-01-01

    Purpose: To determine patient, tumor, and treatment factors predictive of local control (LC) in a series of patients treated with either perioperative high-dose-rate brachytherapy (PHDRB) alone (Group 1) or with PHDRB combined with external-beam radiotherapy (EBRT) (Group 2). Patient and Methods: Patients (n = 312) enrolled in several PHDRB prospective Phase I-II studies conducted at the Clinica Universidad de Navarra were analyzed. Treatment with PHDRB alone, mainly because of prior irradiation, was used in 126 patients to total doses of 32 Gy/8 b.i.d. or 40 Gy/10 b.i.d. treatments after R0 or R1 resections. Treatment with PHDRB plus EBRT was used in 186 patients to total doses of 16 Gy/4 b.i.d. or 24 Gy/6 b.i.d. treatments after R0 or R1 resections along with 45 Gy of EBRT with or without concomitant chemotherapy. Results: No dose-margin interaction was observed in Group 1 patients. In Group 2 patients there was a significant interaction between margin status and 2-Gy equivalent (Eq2Gy) dose (p = 0.002): (1) patients with negative margins had 9-year LC of 95.7% at Eq2Gy = 62.9Gy; (2) patients with close margins of >1 mm had 9-year LC of 92.4% at Eq2Gy = 72.2Gy, and (3) patients with positive/close <1-mm margins had 9-year LC of 68.0% at Eq2Gy = 72.2Gy. Conclusions: Two-gray equivalent doses ≥70 Gy may compensate the effect of close margins ≥1 mm but do not counterbalance the detrimental effect of unfavorable (positive/close <1 mm) resection margins. No dose-margin interaction is observed in patients treated at lower Eq2Gy doses ≤50 Gy with PHDRB alone.

  3. Dependence of some transmission factors on field size and treatment depth in external beam radiation therapy (EBRT) using the theratron equinox 100 cobalt 60 machine

    International Nuclear Information System (INIS)

    Odonkor, P.

    2015-07-01

    The use of beam modifiers in today’s radiotherapy is very important as it attenuates the beam and reduces the dose to the patient; therefore the need to know the amount of attenuation (in terms of a transmission factor) they provide during treatment. The purpose of this research work is to evaluate the variation (or dependence) of the transmission factors (TFs) of block tray and physical wedges (of different angles) as a function of treatment depth and field size using both iso-centric setups, SAD and SSD; and thus compare the results from the two setup techniques. Wedge and tray TF measurements were performed in a full scatter, large water phantom using a 0.04cc ionization chamber and an average photon energy of 1.25MV from a cobalt-60 unit at an SAD/SSD of 100cm at various depths and field sizes with gantry and collimator angles fixed at 0°. From the measurements carried out, the wedge TF of the 15°, 30°, 45°, and 60°, wedges were found to be 0.775±0.005, 0.650±0.010, 0.505±0.015, and 0.280±0.015 respectively; and the tray TF was found to be 0.960±0.003. Also, the results obtained showed that both the wedge TF and the tray TF has a strong linear dependence on treatment depth; however, the variation of the 15°, wedge TF and the tray TF with depth is less significant (less than 2%). Maximum percentage variation for the 15°, wedge for the SAD setup was 1.1% and 1.59% for the SSD setup; and that for the tray was 0.60% for the SAD setup and 0.12% for the SSD setup. Also, the variation of the 15°, 30°, and 45°, wedge TF with field size was less significant (less than 2%); and a weaker dependence was observed with field size as compared to the treatment depth. However, the 60°, wedge showed a significant variation (maximum of 2.22% and 2.88% for the SAD and SSD setups respectively) as an increase in field size was accompanied by an increase in its wedge TF. Also though the tray TF graphically showed a strong linear dependence on field size the

  4. Enhancement of viability of radiosensitive (PBMC and resistant (MDA-MB-231 clones in low-dose-rate cobalt-60 radiation therapy

    Directory of Open Access Journals (Sweden)

    Patrícia Lima Falcão

    2015-06-01

    Full Text Available Abstract Objective: In the present study, the authors investigated the in vitro behavior of radio-resistant breast adenocarcinoma (MDA-MB-231 cells line and radiosensitive peripheral blood mononuclear cells (PBMC, as a function of different radiation doses, dose rates and postirradiation time kinetics, with a view to the interest of clinical radiotherapy. Materials and Methods: The cells were irradiated with Co-60, at 2 and 10 Gy and two different exposure rates, 339.56 cGy.min–1 and the other corresponding to one fourth of the standard dose rates, present over a 10-year period of cobalt therapy. Post-irradiation sampling was performed at pre-established kinetics of 24, 48 and 72 hours. The optical density response in viability assay was evaluated and a morphological analysis was performed. Results: Radiosensitive PBMC showed decrease in viability at 2 Gy, and a more significant decrease at 10 Gy for both dose rates. MDAMB- 231 cells presented viability decrease only at higher dose and dose rate. The results showed MDA-MB-231 clone expansion at low dose rate after 48–72 hours post-radiation. Conclusion: Low dose rate shows a possible potential clinical impact involving decrease in management of radio-resistant and radiosensitive tumor cell lines in cobalt therapy for breast cancer.

  5. Viabilidade e micoflora de sementes de amendoim irradiadas com cobalto (60Co Viability and mycoflora of irradiated seeds of peanut with cobalt (60Co

    Directory of Open Access Journals (Sweden)

    Niédja M. C. Alves

    2011-03-01

    Full Text Available Estudou-se o efeito de diferentes doses da irradiação gama na germinação e percentagem de infecção fúngica em sementes de amendoim cultivar BR1. Inicialmente, as sementes foram avaliadas quanto à micoflora, utilizando-se o método de papel de filtro umedecido, a germinação em substrato de papel germitest e determinação do teor de umidade em estufa, a 105 ± 2 ºC. Posteriormente, as sementes foram submetidas à irradiação com uma fonte de 60Co, tipo gammacell, onde se estudou o efeito de 8 doses de irradiação na micoflora e germinação das sementes acondicionadas em embalagem de PET e polietileno trançado durante 60 dias de armazenamento, sem controle de temperatura e umidade relativa do ar. Os fatores estudados (doses em kGy, embalagens e tempo de armazenamento foram analisados em um delineamento inteiramente casualizado, dispostos em fatorial. Com base nos resultados, observou-se que a irradiação gama afetou negativamente a germinação das sementes de amendoim e que doses acima de 3,0 kGy comprometem a germinação das sementes. A radiação a partir da dose 1,5 kGy eliminou os fungos Aspergillus niger e, Penicillium a partir da dose de 2,5 kGy.The effect of different doses of the gamma irradiation was studied on germination and percentage of fungal infection in peanut seeds cultivar BR1. Initially the seeds were evaluated for the mycoflora using the method of humidified filter paper, the germination in paper substratum germitest and determination of the moisture content in oven at 105 ± 2 ºC. Later on the seeds were submitted to irradiation with a source of 60Co, type gammacell, where the effect was studied of 8 doses of irradiation in the mycoflora and germination of the seeds conditioned in PET packing and polyethylene tressed during 60 days of storage, without control of temperature and relative humidity of the air. The studied factors (doses in kGy, packing and time of storage were analyzed in a completely

  6. Early effects of treatment with radium and cobalt-60 gamma radiation on the proportions and absolute counts of T and B lymphocytes in peripheral blood of women with cervical carcinoma

    International Nuclear Information System (INIS)

    Pluzanska, A.; Robak, T.; Kuchowicz, W.; Bartuzel, T.; Studencki, E.; Zadrozna, O.; Mazurowa, A.

    1977-01-01

    In 20 women with cervical carcinoma the T and B lymphocyte counts were determined in peripheral blood. The determinations were carried out before starting treatment and immediately after radium therapy in a mean dose of 6573 mgh and then after full therapeutic dose of cobalt-60 radiation of 4000 R. For identification of T lymphocytes the rosette E test was used and lymphocytes B were identified by means of the EAC rosette test. Presence of immunoglobulins on lymphocytes B was determined as well. In women with cervical carcinoma the total lymphocyte count in 1 mm 3 of blood, the proportions and absolute counts of T and B lymphocytes were not different from those in healthy women. Immediately after radium therapy the lymphocyte count in peripheral blood fell which was due mainly to a fall of the total count and in the proportion of B lymphocytes. The proportion of lymphocytes T was unchanged and their quantitative fall was statistically not significant. After application of the total therapeutic dose of cobalt-60 radiation a further fall of lymphocyte count was observed, due to a fall of the absolute count of T and B lymphocytes. Their proportions were unchanged. (author)

  7. Sensory evaluation of black beans submitted to gamma radiation from Cobalt-60; Avaliacao sensorial de feijao preto submetido a radiacao de Cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Neila Camargo de; Canniatti-Brazaca, Solange Guidolin; Spoto, Marta Helena Fillet, E-mail: sgcbraza@esalq.usp.b [Escola Superior de Agricultura Luiz de Queiroz (ESALQ/USP), Piracicaba, SP (Brazil). Dept. de Agroindustria, Alimentos e Nutricao; Arthur, Valter [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil). Secao de Entomologia e Irradiacao de Alimentos

    2005-04-15

    The objective of this research was to evaluate the sensory aspects of black beans submitted to gamma radiation from {sup 60}Co. The study involved eight panelists, between 17 to 23 years old, who were selected and trained for the descriptive analysis of appearance, aroma, flavor and texture. The panelists analyzed alterations of appearance, aroma, flavor and texture of non-irradiated and irradiated black beans with doses 2, 4, 6, 8 and 10kGy. The results were analyzed by test F, ANOVA and the Tukey test (5%), with the use of computers and the sensory analysis software Compusense Five and SAS. The results showed that irradiated samples decreased the bitter flavor, accentuated color and brightness and samples non-irradiated dry texture. The radiation treatment is a good method for conservation of black beans in doses evaluated in this study.(author)

  8. Henry Gray, plagiarist.

    Science.gov (United States)

    Richardson, Ruth

    2016-03-01

    The first edition of Anatomy Descriptive and Surgical (1858) was greeted with accolades, but also provoked serious controversy concerning Henry Gray's failure to acknowledge the work of earlier anatomists. A review in the Medical Times (1859) accused Gray of intellectual theft. The journal took the unusual step of substantiating its indictment by publishing twenty parallel texts from Gray and from a pre-existing textbook, Quain's Anatomy. At the recent "Vesalius Continuum" conference in Zakynthos, Greece (2014) Professor Brion Benninger disputed the theft by announcing from the floor the results of a computer analysis of both texts, which he reported exonerated Gray by revealing no evidence of plagiarism. The analysis has not been forthcoming, however, despite requests. Here the historian of Gray's Anatomy supplements the argument set out in the Medical Times 150 years ago with data suggesting unwelcome personality traits in Henry Gray, and demonstrating the utility of others' work to his professional advancement. Fair dealing in the world of anatomy and indeed the genuineness of the lustre of medical fame are important matters, but whether quantitative evidence has anything to add to the discussion concerning Gray's probity can be assessed only if Benninger makes public his computer analysis. © 2015 Wiley Periodicals, Inc.

  9. Dosimetric feasibility of magnetic resonance imaging-guided tri-cobalt 60 preoperative intensity modulated radiation therapy for soft tissue sarcomas of the extremity.

    Science.gov (United States)

    Kishan, Amar U; Cao, Minsong; Mikaeilian, Argin G; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Kamrava, Mitchell

    2015-01-01

    The purpose of this study was to investigate the dosimetric differences of delivering preoperative intensity modulated radiation therapy (IMRT) to patients with soft tissue sarcomas of the extremity (ESTS) with a teletherapy system equipped with 3 rotating (60)Co sources and a built-in magnetic resonance imaging and with standard linear accelerator (LINAC)-based IMRT. The primary study population consisted of 9 patients treated with preoperative radiation for ESTS between 2008 and 2014 with LINAC-based static field IMRT. LINAC plans were designed to deliver 50 Gy in 25 fractions to 95% of the planning target volume (PTV). Tri-(60)Co system IMRT plans were designed with ViewRay system software. Tri-(60)Co-based IMRT plans achieved equivalent target coverage and dosimetry for organs at risk (long bone, skin, and skin corridor) compared with LINAC-based IMRT plans. The maximum and minimum PTV doses, heterogeneity indices, and ratio of the dose to 50% of the volume were equivalent for both planning systems. One LINAC plan violated the maximum bone dose constraint, whereas none of the tri-(60)Co plans did. Using a tri-(60)Co system, we were able to achieve equivalent dosimetry to the PTV and organs at risk for patients with ESTS compared with LINAC-based IMRT plans. The tri-(60)Co system may be advantageous over current treatment platforms by allowing PTV reduction and by elimination of the additional radiation dose associated with daily image guidance, but this needs to be evaluated prospectively. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  10. Energy response of imaging plates to radiation beams from standard beta sources, ortho-voltage and cobalt-60 units and linear accelerators

    Science.gov (United States)

    Gonzalez, Albin Leonel

    literature for comparison purposes. Finally it is important to mention that the dynamic range of the imaging plates measured in this work is about 10 orders of magnitude (10-7--10 3 Gy) where the response is still linear.

  11. Copolymerization of Ethylene Induced by Cobalt-60 Gamma Radiation; Copolymerisation de l'ethylene induite par des rayons gamma du cobalt-60; Sopolimerizatsiya ehtilena pod dejstviem gamma-izlucheniya ot istochnika ks'yali-60; Copolimerizacion del etileno inducida por las radiaciones gamma del cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Steinberg, M.; Colombo, P. [Brookhaven National Laboratory, Long Island, NY (United States)

    1963-11-15

    The gamma radiation initiated copolymerization of ethylene with a number of different monomers was studied at 20{sup o}C and initial pressures up to 680 atm. The experiments were conducted statically in two-phase systems with the exception of the ethylene-carbon monoxide system. Isolation of the copolymers was effected by solvent extraction and fractional precipitation techniques. Infra-red spectroscopy was used for identification. The composition was determined by elemental analysis. A partial evaluation of some of the reaction products including crystalline melting points, densities, solubility characteristics, and molecular weights are given. Evidence of ethylene copolymerization was established with each of the following monomers: styrene, methyl methacrylate, vinyl acetate, acrylonitrile, allyl acetate, isobutylene, chlorotrifluoroethylene, trans 2-butene, methyl acrylate, isoprene, propylene, vinyl chloride, 1-butene, cis 2-butene, carbon monoxide, vinyl pyrrolidone, methyl vinyl ketone, and divinyl benzene. The experimental data obtained in the study of the ethylene-carbon monoxide system were found to obey a linear form of the copolymer composition equation. The ratio of specific rate constants for carbon monoxide and ethylene ({alpha}) was found to have a value of 22.0, indicating that carbon monoxide as a monomer, is activated to the extent that it adds 22 times as fast as an ethylene monomer to an ethylene free-radical chain end. Explosive decomposition was observed to occur during irradiation of ethylene arid chlorotrifluoroethylene under certain irradiation conditions. There is an indication that a threshold radiation intensity exists which induces this violent reaction. The unique advantage of cobalt-60 gamma radiation is that it can be used to induce and control ethylene copolymerization reactions at low temperatures. (author) [French] La copolymerisation de l'ethylene avec divers monomeres provoquee avec des rayons gamma a ete etudiee a 20{sup o

  12. Ionizing radiation effects of Cobalt-60 on the physical-chemical, sensorial and microbiological of bread with addition of linseed (Linum usitatissimum)

    International Nuclear Information System (INIS)

    Moura, Neila Camargo de

    2011-01-01

    The incorporation of functional ingredients on breading products has grown very much lately, because of the preoccupation with the consumers' health. The linseed has awakened the interest by its high level of fiber, lignin, omega-3 and antioxidants compounds. The objective of the present work is evaluate the ionizing radiation effect of 60 Co on the physical-chemical, sensorial and microbiological characteristics of bread with addition of different concentration of brown linseed. There were elaborated 3 types of bread: French roll, form bread prepared with the mixture and form bread produced with conventional ingredients. It was added smashed brown linseed on the bread dough, with concentrations of 8% and 12%. After the preparation, the three kinds of bread packed with polypropylene packages and taken to the IPEN/USP (Institute of Nuclear Energetic Research/University of São Paulo) and irradiated with doses of 6, 8 and 10 kGy. Treatments were elaborated without the addition of linseed and without irradiation, for control, totalizing 12 distinct treatments, to each bread formula tested. Chemical analyses were made (centesimal composition, anti-nutritional compounds, anti-oxidant activity, glycemic index, fat acids, complex B vitamins and minerals); physical analyses (cooking index, volume, color and water activity); sensorial analyses (preference tests and Descriptive Quantitative Analysis - ADQ); microbiological analysis and a survey about irradiated products. It could be seen that the addition of linseed was efficient to increase the level of alimentary fiber and the level of lipids on the 3 bread formula. The three kinds of bread that received the linseed addition and that were not irradiated presented increase on the level of total phenolic; however, when the samples which received the linseed addition were submitted to the irradiation process, it could be noticed the decrease of the antioxidant capacity. There was an increase on the level of omega-3

  13. Hortobágy National Park

    Directory of Open Access Journals (Sweden)

    István Gyarmathy

    2017-06-01

    Full Text Available National parks and protected areas have an important role in protecting starry sky and the undisturbed nighttime environment. Hortobágy which is one of the darkest areas in Hungary, became an International Dark Sky Parks recently. Its significance is mostly related to the protection of the high biodiversity which is endangered by the effects of light pollution. A special monitoring program has been started to survey the nocturnal species and also to monitor the quality of the night sky using   digital cameras. Stargazing night walks are frequently organized. There is a high interest by the general public to attend these night adventures.

  14. Food Irradiation Is Done in Grays, not Rads

    International Nuclear Information System (INIS)

    Strom, Daniel J.

    2002-01-01

    One federal agency has chosen to use exclusively modern SI units of radiation dose in its regulations: the FDA. While not exactly hot news, this bold move by a U.S. government agency on November 26, 1997, should be noted by those who wish to encourage the switch from curies, working level months, rads, rems, and roentgens to becquerels, joule hours per cubic meter, grays, sieverts, and coulombs per kilogram. The regulation is 21 CFR 179, Irradiation in the Production, Processing, and Handling of Food. Specifically, 21 CFR 179.26 (b) 8. permits meat irradiation up to 4.5 kGy for refrigerated meat and 7.0 kGy for frozen meat. Prior to the 1997 addition, radiation doses had been quoted in grays (kGy) with rad (Mrad) values in parentheses. In the 1997 addition, the Mrads disappeared

  15. Study of the effects of Cobalt 60 gamma radiations on the seeds of two textile hibiscus species. Influence of seed water content on their radiosensitivity. Mutagenic effects on two plantlet generation

    International Nuclear Information System (INIS)

    Mahama, Adamou.

    1980-10-01

    This work on textile hibiscus was undertaken for two reasons: to contribute by physical mutagenesis methods to the genetic improvement of these species and especially to obtain the genetic diversity which is seriously lacking in the species sabdariffa var. altissima; to add to research on the effects of mutagenic seed treatments and thus to help towards a better definition of optimum seed irradiation conditions. These two purposes have been fulfilled. The main results may be summed up as follows. - Concerning the improvement of textile hibiscus. Many strains with various new features were selected at the second generation and may lead either to new varieties or at least to interesting precursors for selection programmes. In the second generation derived from Hibiscus saddariffa var. THS 22 some plants were observed with one or more of the following characteristics specific to the edible form: ramified bearing - fleshy calix - smooth leaf. - Concerning the study of mutagenic seed treatment effects. Our experiments showed up the importance of the seed water content and its effect on the response of first-generation plantlets to cobalt 60 γ-ray treatments [fr

  16. The behaviour of cesium 137, chromium 51, cobalt 60, Manganese 54, sodium 22 and zinc 65 in simulated estuarine environments. Effects of suspended mineral particles and dissolved organic matters

    International Nuclear Information System (INIS)

    Mahler, P.

    1985-09-01

    This laboratory investigation studied the retention of 6 radionuclides (cesium 137, chrome 51, cobalt 60, manganese 54, sodium 22 and zinc 65) on three types of clay particles (kaolinite, illite, montmorillonite) and on sediments, suspended in media with salinities ranging between 0 and 34 per mill, with or without organic matters. Measurement of the radioactivity retained by the particles after 5 days' contact with the radionuclide made it possible to calculate the percentages retained and the distribution coefficients, and to follow their evolution versus salinity. Parallel experiments studied the behaviours of the 6 radionuclides as a function of experimental factors (wall effect, contact time..). An exhaustive bibliographic review gives the state-of-the-art of the knowledge. The following conclusions were derived: - the retention of all the radionuclides but chromium 51 decreased as soon as a low salinity appeared. Chromium (available as Cr 3+ ) precipitated quickly and strongly during fixation whatever the surfaces or the conditions: - as for the role of the clay type, illite showed a strong affinity for cesium 137; manganese 54 had a particular behaviour with montmorillonite that enhanced its precipitation into MnO 2 ; with cobalt, sodium and zinc, the percentages retained were always [fr

  17. Study of radio-restoration by various mineral salts and silice wich products (Tuf and Pouzzolane) of rice embryos (oryza-sativa L, Cigalon variety) exposed to cobalt 60 gamma rays

    International Nuclear Information System (INIS)

    Mouthia-Khadija.

    1981-12-01

    Mutagenic treatments produce a large number of mutants per unit time and are used for plant improvement. However these treatments cause damage to cells. To counteract this radio-induced damage 2 methods are being tried: - Protection, which consists in the supply of an active product before application of mutagenic agents; - Restoration, which tries to repair the damage after mutagenic treatment. This work is devoted to restoration processes. Technique for the isolation and culture on a suitable nutrient of rice embryos (oryza sativa L, Cigalon variety) separated from non-irradiated caryopses were developed first. By separating out the embryo in this way it is possible to study in vitro the interactions between the embryo and the rest of the caryopsis (albumin + pericarp). The effects of radiations on embryos from caryopses exposed to cobalt 60 gamma rays were measured next, then the action of certain inorganic elements contained in the caryopsis tissues was analysed. On the basis of the first results obtained the differences in response between plantlets from embryos irradiated or otherwise treated or not either by zinc sulphate or by very silice-rich volcanic products (Tuf and Pouzzolane), were examined by chemical analysis techniques. These tests have allowed the detection of ionic changes induced by irradiation during the different stages of plant development and led to a better estimate of the radio-restoration mechanisms brought about by the various chemical compounds used [fr

  18. Commissioning dosimetry and in situ dose mapping of a semi-industrial Cobalt-60 gamma-irradiation facility using Fricke and Ceric-cerous dosimetry system and comparison with Monte Carlo simulation data

    Science.gov (United States)

    Mortuza, Md Firoz; Lepore, Luigi; Khedkar, Kalpana; Thangam, Saravanan; Nahar, Arifatun; Jamil, Hossen Mohammad; Bandi, Laxminarayan; Alam, Md Khorshed

    2018-03-01

    Characterization of a 90 kCi (3330 TBq), semi-industrial, cobalt-60 gamma irradiator was performed by commissioning dosimetry and in-situ dose mapping experiments with Ceric-cerous and Fricke dosimetry systems. Commissioning dosimetry was carried out to determine dose distribution pattern of absorbed dose in the irradiation cell and products. To determine maximum and minimum absorbed dose, overdose ratio and dwell time of the tote boxes, homogeneous dummy product (rice husk) with a bulk density of 0.13 g/cm3 were used in the box positions of irradiation chamber. The regions of minimum absorbed dose of the tote boxes were observed in the lower zones of middle plane and maximum absorbed doses were found in the middle position of front plane. Moreover, as a part of dose mapping, dose rates in the wall positions and some selective strategic positions were also measured to carry out multiple irradiation program simultaneously, especially for low dose research irradiation program. In most of the cases, Monte Carlo simulation data, using Monte Carlo N-Particle eXtended code version MCNPX 2.7., were found to be in congruence with experimental values obtained from Ceric-cerous and Fricke dosimetry; however, in close proximity positions from the source, the dose rate variation between chemical dosimetry and MCNP was higher than distant positions.

  19. Henry Gray's Anatomy.

    Science.gov (United States)

    Pearce, J M S

    2009-04-01

    Little is generally known of Henry Gray, the author of Gray's Anatomy, and even less of his colleague Henry Vandyke Carter, who played a vital role in the dissections and illustrations leading to the production of the first volume in 1859. This essay attempts to sketch briefly the salient, know aspects of these two men and their divergent careers. It traces succinctly the subsequent fate of the unique anatomy book that has influenced and instructed almost every student of medicine. (c) 2009 Wiley-Liss, Inc.

  20. Cerebral necrosis after 25 Gy radiotherapy in childhood followed 28 years later by 54 Gy radiotherapy

    NARCIS (Netherlands)

    Koot, Radboud W.; Stalpers, Lukas J. A.; Aronica, Eleonora; Bosch, D. Andries

    2007-01-01

    The development of brain necrosis is life-long risk of repeat radiation therapy, even after a long time interval and a moderate radiation dose. We report on a 34-year-old patient who had prophylactic cranial irradiation with 25 Gy and adjuvant chemotherapy in childhood for leukaemia and in

  1. Repairs in 104 Gy/h?

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    In 1989 it was found that in each unit of the MAPS Candu nuclear power station in India the centre portion of the heavy water inlet manifold opposite the 300 mm inlet pipe had torn away. Equipment for remote inspection, repair and removal of debris in an area with constricted and difficult access and radiation fields of about 10 4 Gy/h was developed by Ricardo Hitec of the United Kingdom. This consists of a work performing manipulator, TV viewing systems and a posting tube manipulator for insertion of tools and debris containers into the calandria. A variety of special end effector and tools were also developed jointly with AEA Technology. A first repair campaign was carried out on Unit 1 in 1991. Following a detailed TV survey of the damage a reappraisal of the situation was undertaken and a programme of equipment enhancement carried out. In July 1992 a second repair campaign took place on Unit 2. The difficulties encountered and the degree of success achieved are described. Work proceeded at an intensive level for 14 days when the campaign was ended in view of the exhaustion both of personnel and the equipment. Although more work could have been done a major improvement had been achieved. (UK)

  2. Cobalt 60 cation exchange with mexican clays

    International Nuclear Information System (INIS)

    Nava Galve, R.G.

    1993-01-01

    Mexican clays can be used to remove radioactive elements from contaminated aqueous solutions. Cation exchange experiments were performed with 60 Co radioactive solution. In the present work the effect of contact time on the sorption of Co 2+ was studied. The contact time in hydrated montmorillonite was from 5 to 120 minutes and in dehydrated montmorillonite 5 to 1400 minutes. The Co 2+ uptake value was, in hydrated montmorillonite, between 0.3 to 0.85 m eq/g and in dehydrated montmorillonite, between 0.6 to 1.40 m eq/g. The experiments were done in a pH 5.1 to 5.7 and normal conditions. XRD patterns were used to characterize the samples. The crystallinity was determined by X-ray Diffraction and it was maintained before and after the cation exchange. DTA thermo grams showed the temperatures of the lost humidity and crystallization water. Finally, was observed that dehydrated montmorillonite adsorb more cobalt than hydrated montmorillonite. (Author)

  3. Overview of cobalt-60 external irradiation study

    International Nuclear Information System (INIS)

    Stitzel, K.; Shifrine, M.; Wilson, F.

    1980-01-01

    Work this year has continued to define the immunohematological effects of radiation exposure in Davis beagles over 50 days of age. One case of myeloproliferative disease occurred in one of the animals exposed to 4 R/day, and cases of bone marrow aplasia occurred in the 11 R/day, 4 R/day, and 2 R/day groups. Use of bone marrow transplantation has revealed a profound difference in the mechanism of aplasia induction in dogs which are susceptible to low doses (less than 2000 R exposure at 11 R/day) and dogs which are able to survive in the radiation field for long periods (greater than 3000 R at 11 R/day or 1800 R at 2 R/day). In the latter animals damage occurs to the hematopoietic stromal microenvironment or some other regulatory mechanism which directs the differentiation of the hematopoietic stem cells into the specific end cell pathways (i.e. thrombocytes, red cells neutrophils). In the animals which develop radiation disease after low total exposure, the damage appears to be to the hematopoietic stem cells themselves. This implies that in some animals the stem cells are resistant to massive doses of continuous whole body irradiation, relative to the dose rate

  4. Comparison of humoral immune response, neutralization capacity of anticrotalic serum in young ovines, clinical and weight evaluation between animals inoculated with Crotalus durissus terrificus venom, natural or Cobalt-60-irradiated

    International Nuclear Information System (INIS)

    Ferreira Junior, R.S.

    2005-01-01

    The Elisa technique was used to evaluate and compare the humoral immune response of young ovine to anticrotalic serum production. During serum production, the clinical and weight evaluation of the animals was performed. The parameters utilized were complete blood count, and dosage of urea, creatinine, aspartate aminotransferase, total proteins, albumin and globulin. The animals weight was verified fortnightly during the experiment. The neutralization capacity of the serum produced from the snake Crotalus durissus terrificus natural (NV) and Cobalt-60-irradiated venom (IrV) was evaluated by in vitro challenges. One group of six animals received natural venom, the second group received irradiated venom, and the third was the control group. The animals received six immunizations during 84 days with an interval of 14 days. There was a significant difference (p<5%) in the ELISA test for the profile of the antibodies produced by the experimental groups (NV< IrV). There was no significant difference (p<5%) for biochemical tests, complete blood count, and animals weight between the three groups tested. The group immunized with irradiated venom showed antibodies profile higher than the group immunized with natural venom. The neutralization capacity of the serum produced from the IrV was fivefold higher when compared to the serum produced with NV. The clinical and weight evaluation showed that the o vines in post-weaning phase did not have their physiological profiles altered, and showed an excellent increase in weight during the experimental period. These results indicate a new perspective for the utilization of o vines, aiming the commercial production of anticrotalic serum, which may be applied in the treatment of human and animal envenomation. The cost for its production may be reduced by the posterior utilization of hyperimmunized ovine in human feeding. (author)

  5. Comparison of humoral immune response, neutralization capacity of anticrotalic serum in young ovines, clinical and weight evaluation between animals inoculated with Crotalus durissus terrificus venom, natural or Cobalt-60-irradiated

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Junior, R.S. E-mail: rseabra@cevap.org.br

    2005-07-01

    The Elisa technique was used to evaluate and compare the humoral immune response of young ovine to anticrotalic serum production. During serum production, the clinical and weight evaluation of the animals was performed. The parameters utilized were complete blood count, and dosage of urea, creatinine, aspartate aminotransferase, total proteins, albumin and globulin. The animals weight was verified fortnightly during the experiment. The neutralization capacity of the serum produced from the snake Crotalus durissus terrificus natural (NV) and Cobalt-60-irradiated venom (IrV) was evaluated by in vitro challenges. One group of six animals received natural venom, the second group received irradiated venom, and the third was the control group. The animals received six immunizations during 84 days with an interval of 14 days. There was a significant difference (p<5%) in the ELISA test for the profile of the antibodies produced by the experimental groups (NV

  6. Valine-spectrophotometric readout dosimeter (1 Gy-50 kGy)

    International Nuclear Information System (INIS)

    Nilekani, S.R.; Gupta, B.L.

    2005-01-01

    In this method 20 mg unirradiated/irradiated L-valine powder [(CH 3 ) 2 CH.NH 2 CH.COOH] is dissolved in 10 ml of a solution containing 4x10 -4 mol dm -3 Fe 2+ and 2.5x10 -4 mol dm -3 xylenol orange (XO) in aerated aqueous 0.060 mol dm -3 sulphuric acid (FX). The plot of absorbance at 550 nm against dose is non linear. A dose of 1-50 kGy can be measured. However, dosimeter can be sensitized in the dose range of 1 to 16 kGy by dissolving 50-mg valine powder in 10 ml of a solution which contains 5x10 -4 mol dm -3 Fe 2+ and 3x10 -4 mol dm -3 XO in aerated aqueous 0.065 mol dm -3 sulphuric acid. The plot of absorbance at 549 nm against dose is non-linear. However, dosimeter shows linear response when 500 mg unirradiated/irradiated L-valine powder is dissolved in 10 ml of a solution containing 7.5x10 -4 mol dm -3 Fe 2+ and 3x10 -4 mol dm -3 XO in aerated aqueous 0.25 mol dm -3 sulphuric acid. The plot of absorbance at 557 nm against dose is linear in the dose range of 20-400Gy and doses down to about 1 Gy can be measured using 10-cm path cells. Response of the dosimeter is independent of irradiation temperature in the temperature range 20-50 deg C. Irradiated valine powder is stable for about 1 month. The reproducibility of the method is better than ±2%. This dosimeter is very useful as transfer dosimeter for food irradiation and radiation sterilization

  7. Dosimetric reevaluation of exposure at working stations of the Mafelec Society. Presence on the production site of elevators push-button containing cobalt 60 between the 21. august and the 7 october 2008; Reevaluation dosimetrique des expositions aux postes de travail de la Societe Mafelec. Presence sur le site de production de poussoirs de boutons et de boutons d'ascenseur contenant du cobalt 60 entre le 21 aout et le 7 octobre 2008

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2008-07-01

    On the 7. october 2008, the public authorities were alerted by the Mafelec society of the detection by their customs services of unusual levels of radioactivity during controls on packages containing elevators push-buttons sent by this society. The first measures made on that very day on the site of the Mafelec society at Chimilin (38) by the mobile cell of radiological intervention of Isere department firemen enlightened the presence of radioactivity in elevators the push-buttons in stainless steel and in complete push-buttons delivered to Mafelec by one or several Indian suppliers. After having made an inspection on the site on the 8. october, the nuclear safety authority requested the help of I.R.S.N. to evaluate the doses received by the facility personnel exposed to these radioactive pieces. The Asn also asked I.R.S.N. to evaluate the public exposure if someone used an elevator equipped with such buttons. The first evaluations showed that 22 persons had received a maximal dose between 1.4 and 2.7 mSv. A second report (on the 27 october 2008) gave a revaluation of the dosimetry and went back to the dosimetric evaluation for a person of the public that would take an elevator with push-buttons containing cobalt 60: scenario: presence of a person during 5 minutes by day in the elevator at 50 cm from the control board and that 300 days by year, for this situation the dose received by a person of the public would be about 150 {mu}Sv. (N.C.)

  8. The Internet And Gray Marketing

    OpenAIRE

    Soumava Bandyopadhyay

    2010-01-01

    The purpose of this conceptual paper is to investigate the nature, extent, and outcomes of gray marketing on the Internet.  We examined the current state of Internet-based gray marketing in several product categories and found the phenomenon to be on the rise.  Next, we developed a series of propositions to address evolving trends in online gray marketing, regarding actions of intermediaries and manufacturers, response by consumers, and outcomes on marketing strategy.

  9. Grays Harbor Paper

    Energy Technology Data Exchange (ETDEWEB)

    Quigg, B. [Grays Harbor Paper, Hoquiam, WA (United States)

    2009-07-01

    Wood waste biomass boilers are used at Grays Harbor Paper in Hoquiam, Washington. This presentation showed that large volumes of biomass are left after a traditional clearcut. The opportunities and challenges of collecting branches, tops and stumps from this wet coastal climate were outlined. The paper described some of the low-tech methods for picking up branches, stumps and woody debris. It included several photographs of custom logging machines for timber harvest, including a brush grapple slasher, a shearer shovel, chippers, grinders, slicesaws, trucks, trailers and caterpillar log loaders for handling slash. The slash recovery program relies on innovative harvesting machines that convert scattered logging slash into bundles that can be easily collected, transported, and stored for use in existing facilities that utilize wood fiber for fuel. figs.

  10. Why Does Hair Turn Gray?

    Science.gov (United States)

    ... out, but people with naturally lighter hair are just as likely to go gray. From the time a person notices a few gray hairs, it may take more than 10 years for all of that person's hair to turn ... really believe that this happens. Just in case, try not to freak out your ...

  11. Novel Amdovirus in Gray Foxes

    Science.gov (United States)

    Li, Linlin; Pesavento, Patricia A.; Woods, Leslie; Clifford, Deana L.; Luff, Jennifer; Wang, Chunlin

    2011-01-01

    We used viral metagenomics to identify a novel parvovirus in tissues of a gray fox (Urocyon cinereoargenteus). Nearly full genome characterization and phylogenetic analyses showed this parvovirus (provisionally named gray fox amdovirus) to be distantly related to Aleutian mink disease virus, representing the second viral species in the Amdovirus genus. PMID:22000359

  12. Physico chemical and microbiological changes in nopal (Opuntia spp.) irradiated with gamma rays of cobalt 60; Cambios fisicoquimicos y microbiologicos en nopal (Opuntia spp.) irradiado con rayos gamma de cobalto 60

    Energy Technology Data Exchange (ETDEWEB)

    Perez N, M

    2001-07-01

    The objective of this work is to study the physico-chemical and microbiological changes which take place in the nopal (Opuntia spp.) after they have been irradiated and stored at environment and refrigeration temperatures in order to determine the level of irradiation dose more adequate for getting them an increase in the storage life, as well as to determine the physico-chemical changes attributed to the irradiation doses used, comparing the obtained results with those ones of non-irradiated nopal samples, which are considered as control samples. The radiation source used was a GAMMABEAM-651 PT, property of the Nuclear Sciences Institute of UNAM. The nopals studied are of the variety (Milpa Alta, Opuntia ficus) which were cut and packed in polyethylene bags with and without nitrogen. In order to find the adequate dose level it was used a lot of 200 samples which were treated in sets of 10. They were irradiated in doses of 0.5 to 10 kGy at a dose reason of 3.7 kGy/h. The adequate doses for getting an increase in the storage life, where there was not darkness were of 1.5 and 2.0 kGy, allowed doses in the NOM-033-SSA1-1993, it was not found any change in acceptability by flavour, but so in the titled activity values and sugars. The lowest loss of weight was found in the 1.5 kGy dose without nitrogen and the highest in the 2.0 kGy with nitrogen dose. Likewise was determined that with the irradiation treatment in the recommended doses it is diminished the microorganisms growth, obtaining an improvement in the general appearance of the nopals during their storage period. (Author)

  13. The Gray whale: Eschrichtius robustus

    National Research Council Canada - National Science Library

    Jones, Mary Lou; Leatherwood, Stephen; Swartz, Steven L

    1984-01-01

    .... Section II documents historical aspects of gray whale exploitation and the economic importance of these whales to humans, beginning with aboriginal societies in Asia and North America, and leading...

  14. Niobium in gray cast iron

    International Nuclear Information System (INIS)

    Castello Branco, C.H.; Beckert, E.A.

    1984-03-01

    The potential for utilization of niobium in gray cast iron is appraised and reviewed. Experiments described in literature indicate that niobium provides structural refinement of the eutectic cells and also promotes pearlite formation. (Author) [pt

  15. The GETUG 70 Gy vs. 80 Gy randomized trial for localized prostate cancer: Feasibility and acute toxicity

    International Nuclear Information System (INIS)

    Beckendorf, Veronique; Guerif, Stephane; Le Prise, Elisabeth; Cosset, Jean Marc; Lefloch, Olivier; Chauvet, Bruno; Salem, Naji; Chapet, Olivier; Bourdin, Sylvain; Bachaud, Jean Marc; Maingon, Philippe; Lagrange, Jean-L.eon; Malissard, Luc; Simon, Jean-Marc; Pommier, Pascal M.D.; Hay, Men H.; Dubray, Bernard; Luporsi, Elisabeth; Bey, Pierre

    2004-01-01

    Purpose: To describe treatments and acute tolerance in a randomized trial comparing 70 Gy and 80 Gy to the prostate in patients with localized prostate cancer. Methods and materials: Between September 1999 and February 2002, 306 patients were randomized to receive 70 Gy (153 patients) or 80 Gy (153 patients) in 17 institutions. Patients exhibited intermediate-prognosis tumors. If the risk of node involvement was greater than 10%, surgical staging was required. Previous prostatectomy was excluded, and androgen deprivation was not admitted. The treatment was delivered in two steps. PTV1-including seminal vesicles, prostate, and a 1-0.5-cm margin-received 46 Gy given with a 4-field conformal technique. PTV2, reduced to prostate with the same margins, irradiated with at least 5 fields. Dose was prescribed according to ICRU recommendations in the 70 Gy group, but adapted at the 80 Gy level. Results: All patients but one in the 80 Gy arm completed the treatment. In the 70 Gy arm, the mean dose to the PTV2 was 69.5 Gy. In the 80 Gy arm, the mean dose in the PTV2 was 78.5 Gy. Acute toxicity according to Radiation Therapy Oncology Group scale during treatment was reported in 306 patients. There was no statistically significant difference between the two arms: 12% had no toxicity, 80% complained of bladder toxicity, and 70% complained of rectal symptoms. Two months after the end of treatment, 43% of the 70 Gy level and 48% of the 80 Gy level complained of side effects, including 24% and 20% of sexual disorders. There was 6% and 2% of Grade 3 urinary and rectal toxicity. Five patients required a 10-29-day suspension of the treatment. Acute Grade 2 and 3 side effects were related to PTV and CTV1 size, which was the only independent predictive factor in multivariate analysis. Toxicity was not related to the center, age, arm of treatment, or selected data from dose-volume histogram of organ at risk. Conclusion: Treatments were completed in respect to constraints. Acute toxicity

  16. Comparison between external beam radiotherapy (70 Gy/74 Gy) and permanent interstitial brachytherapy in 890 intermediate risk prostate cancer patients

    International Nuclear Information System (INIS)

    Goldner, Gregor; Pötter, Richard; Battermann, Jan J.; Kirisits, Christian; Schmid, Maximilian P.; Sljivic, Samir; Vulpen, Marco van

    2012-01-01

    Purpose: Aim of this analysis was to compare biochemical no evidence of disease (bNED) rates in intermediate-risk prostate-cancer patients treated at two centres of excellence using different approaches: permanent interstitial brachytherapy (BT) and external beam radiotherapy (EBRT). Materials and methods: A total of 890 intermediate-risk prostate-cancer patients, who were treated from 1998 to 2008, were identified in the two local databases. In Utrecht 601 patients received I-125 BT applying a dose of 144 Gy. In Vienna 289 patients were treated by EBRT, applying a local dose of 70 Gy in 105 patients and 74 Gy in 184 patients. bNED-rates (Phoenix-definition) were assessed. Results: Median follow-up was 48 months (1–150). 5-Year actuarial bNED-rates were 81% for BT-patients and 75% for EBRT-patients (67% for 70 Gy and 82% for 74 Gy), respectively. In univariate analysis no difference between BT and EBRT could be detected. In multivariate analysis including tumour-stage, GleasonScore, initial PSA, hormonal therapy and treatment-centre (BT vs. EBRT) only T-stage, GleasonScore and PSA were found to be significant. Additional analysis including radiation dose showed the same outcome. Conclusions: Intermediate-risk prostate cancer patients treated by permanent interstitial brachytherapy show biochemical tumour-control-rates which are comparable to EBRT of 74 Gy.

  17. Investigation of the effect of temperature, dose rate and short-term post-irradiation change on the response of various types of dosimeters to cobalt-60 gamma radiation for quality assurance in Thailand

    International Nuclear Information System (INIS)

    Biramontri, S.

    2000-01-01

    The influences of combined effect of irradiation temperature from -80 deg. C to 60 deg. C and dose rate between 0.2 and 4 Gy/s on the gamma ray response of several commercial routine dosimeters (Harwell Red 4034, Gammachrome YR, FWT-60-00 radiochromic films, FWT-70-40 optical waveguides, GafChromic films, and Fuji CTA-FTR-125 films) were investigated for quality assurance in radiation processes. Besides, the studies of short term post-irradiation stability for the period of 2 h to 7 days are also presented. The overall results indicate the need for a calibration protocol under conditions of use. (author)

  18. Advanced gray rod control assembly

    Science.gov (United States)

    Drudy, Keith J; Carlson, William R; Conner, Michael E; Goldenfield, Mark; Hone, Michael J; Long, Jr., Carroll J; Parkinson, Jerod; Pomirleanu, Radu O

    2013-09-17

    An advanced gray rod control assembly (GRCA) for a nuclear reactor. The GRCA provides controlled insertion of gray rod assemblies into the reactor, thereby controlling the rate of power produced by the reactor and providing reactivity control at full power. Each gray rod assembly includes an elongated tubular member, a primary neutron-absorber disposed within the tubular member said neutron-absorber comprising an absorber material, preferably tungsten, having a 2200 m/s neutron absorption microscopic capture cross-section of from 10 to 30 barns. An internal support tube can be positioned between the primary absorber and the tubular member as a secondary absorber to enhance neutron absorption, absorber depletion, assembly weight, and assembly heat transfer characteristics.

  19. Grays River Watershed Geomorphic Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Geist, David R

    2005-04-30

    This investigation, completed for the Pacific Northwest National Laboratory (PNNL), is part of the Grays River Watershed and Biological Assessment commissioned by Bonneville Power Administration under project number 2003-013-00 to assess impacts on salmon habitat in the upper Grays River watershed and present recommendations for habitat improvement. This report presents the findings of the geomorphic assessment and is intended to support the overall PNNL project by evaluating the following: The effects of historical and current land use practices on erosion and sedimentation within the channel network The ways in which these effects have influenced the sediment budget of the upper watershed The resulting responses in the main stem Grays River upstream of State Highway 4 The past and future implications for salmon habitat.

  20. Utilisation of gamma radiation of Cobalt-60 as quarantine treatment of medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne (Fabricius, 1792) (Coleoptera, Anobiidae) and Plodia interpunctella (Hubner, 1813) (Lepidoptera, Pyralidae)

    International Nuclear Information System (INIS)

    Alves, Juliana Nazare

    2007-01-01

    The research had as objective the use of the gamma radiation of the Cobalto-60 as quarantine treatment of the medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne and Plodia interpunctella determining the disinfestation doses to attend the criterion in the not emergency of adults of the species in study and analysing through the Chromatography of Thin Layer the effect of the gamma radiation of the cobalto-60 on the active principle of extract dehydrated of Chamomilla recutita, Pimpinella anisum, Origanum vulgare, Cymbopogon citratus, Ocimum basilicum and Thymus vulgaris. The work was developed in the Laboratorio de Inseticidas in the Instituto Biologico in Sao Paulo in the period of August of 2005 the June of 2007. The radiation source used gamma was an experimental irradiator of Cobalto-60, model Gamacell 220, located in the Instituto de Pesquisas Energeticas e Nucleares - IPEN, located in Sao Paulo. In the period of 30 days after the irradiation of the samples evaluated the number of adults emerged of Lasioderma serricorne and Plodia interpunctella, using the data of mortality for the analysis of Probit. Obtained 100% of not emergency of adults in the Lasioderma serricorne with the dose of 2,00 kGy and 100% of not emergency of adults in the Plodia interpunctella with the dose of 2,25 kGy. The Chromatographic Analysis of Thin Layer was to evaluate did not show chemical differences in the extracts analysed. (author)

  1. 45 Gy - tolerance dose spinal cord - dogma or the facts?

    International Nuclear Information System (INIS)

    Maciejewski, B.; Hliniak, A.; Danczak-Ginalska, Z.; Meder, M.; Skolyszewski, J.; Reinfuss, M.; Korzeniowski, S.; Peszynski, J.; Jassem, J.

    1993-01-01

    Dose of 45 Gy as a tolerance dose for spinal cord was questioned based on review of clinical data. Some data show that for conventional fractionation with the dose per fraction of less than 2.0 Gy spinal cord tolerance dose may arise up to 50-55 Gy. This was the base for round-table discussion and the importance of clinical and physical risk factors of postirradiation spinal cord injury was discussed and previous diseases of spinal cord, size of dose per fraction and length of irradiated spinal cord were pointed out as high risk factors. It was concluded that from clinical point of view there is no reason and on need to verify and to increase tolerance dose for spinal cord. (author)

  2. Application gamma radiation of cobalt-60 in disinfestation of some types of rations for feeding small animals; Emprego da radiacao gama do cobalto-60 na desinfestacao de alguns tipos de racoes para alimentacao de animais de pequeno porte

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, Paula Bergamin

    2012-07-01

    The pests as beetles, mites, moths and mushrooms among other, usually infest products stored as: grains, crumbs, flours, coffee, tobacco, dried fruits, animal rations, spices, dehydrated plants, causing the visual depreciation and promoting to deterioration of the products. The present research had as objective the use of the gamma radiation in the disinfestation of some types of rations used for feeding animals of small size. In the first experiment packing of free samples were used measuring 10 cm x 20 cm with capacity of 70 grams of substrate (ration) with 4 types of existent marks in the trade: (1), (2), e (3), and (4). Each treatment consisted of 10 repetitions, that were irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy, to do the disinfestation of the samples. After the irradiation (disinfestation) of the all irradiated packing and more the control was conditioned in plastic boxes of 80 cm x 50 cm with cover, where the insects were liberated Lasioderma serricorne, Plodia interpuctella, Sitophilus zeamais and Sitophilus oryzae, in a total of 400 for each box and maintained at room acclimatized with 27 {+-} 2 Deg C and relative humidity of 70 {+-} 5%. In the second experiment packing were used made with the materials of packing of the first experiment. Each packing was made of 10 cm x 15 cm, with capacity of 30 grams of substrate (ration). In each repetition was inoculated 10 insects of each species, in a total of 400 insects for experiment per box. The packing with substrate and insect, were stamped in commercial machine and irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy. The irradiated packing and the control were maintained at room acclimatized same the mentioned in the first experiment. The counting of the number of insects and holes in the packing were made after 60 days. Concluded that only the packing of the ration type number 4 was susceptive to attack of all species of insects. The dose of 0,5 kGy was sufficient to induce the

  3. The Picture of Dorian Gray

    NARCIS (Netherlands)

    Wilde, Oscar

    2005-01-01

    On its first publication The Picture of Dorian Gray was regarded as dangerously modern in its depiction of fin-de-sicle decadence. In this updated version of the Faust story, the tempter is Lord Henry Wotton, who lives selfishly for amoral pleasure; Dorian's good angel is the portrait painter Basil

  4. Paulette Gray, Ph.D.

    Science.gov (United States)

    Paulette S. Gray, Ph.D. is the Director for the Division of Extramural Activities (DEA). As the director of the division, she is responsible for the overall scientific, fiscal, and administrative management of the division, including broad strategic planning, development, implementation, and evaluation.

  5. Tsenseerimata Dorian Gray? / Udo Uibo

    Index Scriptorium Estoniae

    Uibo, Udo, 1956-

    2011-01-01

    Harvardi ülikooli kirjastus üllitas 2011. a. kevadel Oscar Wilde'i ainsaks jäänud romaani "Dorian Gray portree" esialgse versiooni, mis on varustatud toimetaja Nicholas Frankeli põhjalike kommentaaridega ja kus eessõna manifesteerib jõuliselt autori esteetilisi vaateid

  6. Main aspects in licensing of a type B(U) package design for the transport of 12.95 PBq of cobalt 60; Aspectos relevantes del licenciamiento en Argentina de un modelo de bulto tipo B(U) para transporte de 12,95 PBq de cobalto 60

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Vietri, J R; Novo, R G; Bianchi, A J

    1996-12-31

    This paper points out the relevant technical issues related to the licensing process, of a type B(U) package design, with cylindrical form and 9.3 ton mass, approved by the Argentine Competent Authority for the transport of 12.95 PBq of cobalt 60 as special form radioactive material. It is briefly described the heat transfer analysis, the structural performance under impulsive loads and the shielding calculation under both normal and accidental conditions of transport, as well as the comparative analysis of the results obtained from design, pre-operational tests and independent evaluation performed by the Argentine Competent Authority to verify the compliance with the Regulations for the Safe Transport of Radioactive Material of the International Atomic Energy Agency. (author). 14 refs., 1 fig., tabs.

  7. INDUCTION OF ARTIFICIAL MEIOTIC GY~OGENESIS WITH ...

    African Journals Online (AJOL)

    BSN

    INDUCTION OF ARTIFICIAL MEIOTIC GY~OGENESIS WITH. ULTRAVIOLET RAYS IN THE AFRICA:" CATFISH, CI.ARIAS. ANGUILLARIS. ABSTRACT. P.O. ALUKO. National Institute for Freshwater Fisheries. Research, P.M.B. 6006, New Bussa. Artificial gynogenesis was induced in Clarias a11gw aris ) fenilizing the eggs ...

  8. Lowy, Schiller win 2018 Szent-Györgyi Prize

    Science.gov (United States)

    A press release announcing that NCI scientists Douglas R. Lowy and John T. Schiller will receive the 2018 Szent-Györgyi Prize for Progress in Cancer Research from the National Foundation for Cancer Research for their work on HPV vaccines.

  9. Feasibility of magnetic resonance imaging-guided liver stereotactic body radiation therapy: A comparison between modulated tri-cobalt-60 teletherapy and linear accelerator-based intensity modulated radiation therapy.

    Science.gov (United States)

    Kishan, Amar U; Cao, Minsong; Wang, Pin-Chieh; Mikaeilian, Argin G; Tenn, Stephen; Rwigema, Jean-Claude M; Sheng, Ke; Low, Daniel A; Kupelian, Patrick A; Steinberg, Michael L; Lee, Percy

    2015-01-01

    The purpose of this study was to investigate the dosimetric feasibility of liver stereotactic body radiation therapy (SBRT) using a teletherapy system equipped with 3 rotating (60)Co sources (tri-(60)Co system) and a built-in magnetic resonance imager (MRI). We hypothesized tumor size and location would be predictive of favorable dosimetry with tri-(60)Co SBRT. The primary study population consisted of 11 patients treated with SBRT for malignant hepatic lesions whose linear accelerator (LINAC)-based SBRT plans met all mandatory Radiation Therapy Oncology Group (RTOG) 1112 organ-at-risk (OAR) constraints. The secondary study population included 5 additional patients whose plans did not meet the mandatory constraints. Patients received 36 to 60 Gy in 3 to 5 fractions. Tri-(60)Co system SBRT plans were planned with ViewRay system software. All patients in the primary study population had tri-(60)Co SBRT plans that passed all RTOG constraints, with similar planning target volume coverage and OAR doses to LINAC plans. Mean liver doses and V10Gy to the liver, although easily meeting RTOG 1112 guidelines, were significantly higher with tri-(60)Co plans. When the 5 additional patients were included in a univariate analysis, the tri-(60)Co SBRT plans were still equally able to pass RTOG constraints, although they did have inferior ability to pass more stringent liver and kidney constraints (P < .05). A multivariate analysis found the ability of a tri-(60)Co SBRT plan to meet these constraints depended on lesion location and size. Patients with smaller or more peripheral lesions (as defined by distance from the aorta, chest wall, liver dome, and relative lesion volume) were significantly more likely to have tri-(60)Co plans that spared the liver and kidney as well as LINAC plans did (P < .05). It is dosimetrically feasible to perform liver SBRT with a tri-(60)Co system with a built-in MRI. Patients with smaller or more peripheral lesions are more likely to have optimal liver

  10. Biodegradation polyurethane derived from vegetable oil irradiated with gamma rays 25 kGy and 100 kGy; Biodegradacao de poliuretano derivado de oleo vegetal irradiado com raios gama 25 kGy e 100 kGy

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Antonia M. dos, E-mail: amsantos@rc.unesp.br [Universidade Estadual Paulista - Unesp, Rio Claro, SP (Brazil); Claro Neto, Salvador [Universidade de Sao Paulo - USP, Campus de Sao Carlos, SP (Brazil); Azevedo, Elaine C. de [Universidade Federal do Parana, Campus de Curitiba, PR (Brazil)

    2011-07-01

    The environment requires polymers that can be degraded by the action of microorganisms. In this work was studied the biodegradation of polyurethane samples derived from vegetable oil (castor oil), which were irradiated with gamma rays 25 kGy and 100 kGy compared with the same polyurethane without being irradiated. Biodegradation of polyurethane was carried out in culture medium containing the fungus Aspergillus niger by 146 days and the result was evaluated using the technique of thermogravimetric analysis, where there was a change of behavior of the curves TGA / DTG occurred indicating that chemical modifications of molecules present in the structure of the polymer chain, thus confirming that the material has undergone the action of microorganisms. (author)

  11. Services of Economic Development Organisations in Győr

    Directory of Open Access Journals (Sweden)

    Adrienn Reisinger

    2017-12-01

    Full Text Available Economic development of a municipality is highly depended on organizations and institutions, which services target local entrepreneurs and other economic actors. In the summer of 2015 we have collected and mapped the services of organizations with the function of economic development in the Hungarian city, Győr. Through our research we could identify the services and the characteristics of linkages and cooperation of the economic development organizations (EDOs. Most important findings of the study are the followings: activity of the organizations has a wide range. Some of them are presented in more organizations at the same time. Level of diversification is quite low. Directions of cooperation are mainly based on personal or ad hoc relations. We conducted that EDOs know about each other, despite of this fact the number of linkages is low. In this paper we provide findings about Győr, but the results can be used for other settlements’ economic development, too.

  12. Gray Code for Cayley Permutations

    Directory of Open Access Journals (Sweden)

    J.-L. Baril

    2003-10-01

    Full Text Available A length-n Cayley permutation p of a total ordered set S is a length-n sequence of elements from S, subject to the condition that if an element x appears in p then all elements y < x also appear in p . In this paper, we give a Gray code list for the set of length-n Cayley permutations. Two successive permutations in this list differ at most in two positions.

  13. Biodegradation polyurethane derived from vegetable oil irradiated with gamma rays 25 kGy and 100 kGy

    International Nuclear Information System (INIS)

    Santos, Antonia M. dos; Claro Neto, Salvador; Azevedo, Elaine C. de

    2011-01-01

    The environment requires polymers that can be degraded by the action of microorganisms. In this work was studied the biodegradation of polyurethane samples derived from vegetable oil (castor oil), which were irradiated with gamma rays 25 kGy and 100 kGy compared with the same polyurethane without being irradiated. Biodegradation of polyurethane was carried out in culture medium containing the fungus Aspergillus niger by 146 days and the result was evaluated using the technique of thermogravimetric analysis, where there was a change of behavior of the curves TGA / DTG occurred indicating that chemical modifications of molecules present in the structure of the polymer chain, thus confirming that the material has undergone the action of microorganisms. (author)

  14. Onset of behavioral effects in mice exposed to 10 Gy Co-60 radiation

    International Nuclear Information System (INIS)

    Maier, D.M.; Landauer, M.R.

    1990-01-01

    The effects of 10 Gray (Gy) Co-60 radiation on social behavior, locomotor activity, and body weight were assessed in individually housed male Swiss-Webster mice. In experiment 1, aggressive behavior was evaluated prior to irradiation and for 7 d postirradiation by placing an untreated intruder in the irradiated or sham-irradiated resident's home cage for 5 min. Offensive aggressive behavior was not affected significantly by radiation until day 7 postirradiation, when attack latency increased, the frequency and duration of fighting decreased, and the frequency of bites, lunges, and chases decreased. Untreated intruder mice paired with irradiated resident mice showed a decrease in the duration of defensive upright postures and a decrease in the frequency of defensive upright postures, squeaks, and escapes on day 7 postirradiation. In experiment 2, locomotor activity and body weight were monitored for 7 d postirradiation. Body weight was decreased in irradiated mice beginning 4 d postirradiation. Locomotor activity was suppressed in irradiated animals 90 min after irradiation and remained depressed throughout the 7-d testing period. 25 refs

  15. The Effect of Illumination on Gray Color

    Science.gov (United States)

    Da Pos, Osvaldo; Baratella, Linda; Sperandio, Gabriele

    2010-01-01

    The present study explored the perceptual process of integration of luminance information in the production of the gray color of an object placed in an environment viewed from a window. The mean luminance of the object was varied for each mean luminance of the environment. Participants matched the gray color of the object with that of Munsell…

  16. Photometry of the long period dwarf nova GY Hya

    Science.gov (United States)

    Bruch, Albert; Monard, Berto

    2017-08-01

    Although comparatively bright, the cataclysmic variable GY Hya has not attracted much attention in the past. As part of a project to better characterize such systems photometrically, we observed light curves in white light, each spanning several hours, at Bronberg Observatory, South Africa, in 2004 and 2005, and at the Observatório do Pico dos Dias, Brazil, in 2014 and 2016. These data permit to study orbital modulations and their variations from season to season. The orbital period, already known from spectroscopic observations of Peters and Thorstensen (2005), is confirmed through strong ellipsoidal variations of the mass donor star in the system and the presence of eclipses of both components. A refined period of 0.34723972 (6) days and revised ephemeries are derived. Seasonal changes in the average orbital light curve can qualitatively be explained by variations of the contribution of a hot spot to the system light together with changes of the disk radius. The amplitude of the ellipsoidal variations and the eclipse contact phases permit to put some constraints on the mass ratio, orbital inclination and the relative brightness of the primary and secondary components. There are some indications that the disk radius during quiescence, expressed in units of the component separation, is smaller than in other dwarf novae.

  17. Eileen Gray: a child of Japonism?

    OpenAIRE

    Starr, Ruth

    2008-01-01

    Exhibited at the Glucksman Memorial Symposium on June 12th 2008 My interest is in Gray's lacquer work and the influences on that work in the context of nineteenth-century fashion of Japonisme. Gray (1878-1976) had an appreciation of the Japanese characteristics of lacquer - perhaps absorbed from private and public Irish collections of Japanese art. Gray also had a twenty-year working collaboration with Seizo Sugawara (1884-1937) from Jahoji, Japan - a town famous for its lacquer work. Suga...

  18. MR imaging of heterotopic gray matter

    International Nuclear Information System (INIS)

    Kryst-Widzgowska, T.; Kozlowski, P.; Poniatowska, R.

    1994-01-01

    Six patients with heterotopic gray matter were evaluated with MR. 5 patients had history of seizures. 4 cases were suspected of the cerebral tumor. In the MR examination areas of heterotopic gray matter were found along the posterior horn of the lateral ventricle on the one side in 4 cases and bilateraly in 2 cases. In 3 cases another brain abnormalities were also detected including: hypoplasia of corpus callosum, hypoplasia of brain hemisphere, cavum septi pellucidi. MR is a modality of choice in the assessment of abnormal gray matter migration. (author)

  19. REVISS cobalt-60 production in Russia and beyond

    Science.gov (United States)

    Coppell, David; Latham, Ian; Nazarov, Michael

    2004-09-01

    Since Russian English Venture in Isotope Supply and Services (REVISS) Services is one of only two major global suppliers of sealed radiation sources to the industrial sterilization industry, security of supply of raw materials is understandably of primary concern to the users in the market place. This paper outlines the history, facilities and production capability of REVISS isotope suppliers, from MAYAK Production Association and Leningrad Nuclear Power Plant in Russia to Commission Nacional Energia Atomica in Argentina. The paper provides technical details of reactors and handling facilities used for fabrication of 60Co and 137Cs sources for industrial and research gamma irradiators and other applications. Other sources of 60Co in the world today will be reviewed briefly.

  20. Cobalt-60 production in the BN-350 fast power reactor

    International Nuclear Information System (INIS)

    Zvonarev, A.V.; Korobejnikov, V.V.; Matveenko, I.P.

    1994-01-01

    A possibility of Co-60 isotope production in the BN-350 fast reactor was considered. A special irradiating device, which is an assembly with a central hole, where a container containing cobalt and zirconium hydride is placed. The irradiating device tested permits generating 60 Co with specific activity of 100 Ci/g

  1. Development and production of cobalt-60 sources for metallurgical application

    International Nuclear Information System (INIS)

    Oliveira, Paulo Fernando; Valente, Eduardo Sarmento; Maretti Junior, Fausto

    2002-01-01

    The CDTN has developed and produced 60 Co sources to be used in level controllers on continuous ingot casting. The sources used in these systems are sealed with a stainless steel revetment and have an useful life equivalent to one half life of the 60 Co (5.272 years). Each system of continuous ingot casting uses a source with one specified activity and different activation section. The sources have been imported with a very high cost due the special shields used to keep and transport them safety. One of its sources, with initial activity of 148 MBq, after being used for more than 5 years in one factory, was given to CDTN to carry out an activation section studies. After these studies be concluded CDTN/CNEN began the procedures to produce a new source in the IPR-R1 TRIGA Reactor, with an irradiation of one cobalt wire in the maximum flux region of the core. The same metallic cobalt wire was irradiated (10% of total activity), to determinate the necessary irradiation time to obtain the final activation. The CDTN developed too a stainless steel recipient with a aluminum nucleus, to seal and to guarantee the integrity of the source. (author)

  2. R I 800. A new cobalt-60 sealed source design

    International Nuclear Information System (INIS)

    Freijo, Jose L.; Gomez, Gonzalo

    2006-01-01

    The consolidation of the international market of Co-60 sources and the perspective of its growth has encouraged the development of new types of sealed sources. The model R I 800 is designed for activities up to 65 kCi and allows a large spectrum of capsules with different specific activities. During three years Dioxitek developed the process of fabrication and qualifications to comply the design requirements and succeeded in the product approval. Today, the initial lot at an industrial scale of R I 800 sources is under fabrication and a first partial shipment of 100 kCi to the United Kingdom was successfully carried out at the end of October 2005. The whole lot is for export. Due to the versatility of the R I 800 sealed sources it was possible to use as raw material 1 MCi of Co-60 imported from Russia, irradiated in Leningrad nuclear power plant. (author) [es

  3. Radiation incidents with a cobalt-60 teletherapy unit

    Energy Technology Data Exchange (ETDEWEB)

    Lane, R G; Tolbert, D D; Pailwal, B R; Radtke, R R [Wisconsin Univ., Madison (USA). Dept. of Radiology

    1976-08-01

    Three radiation incidents associated with source drive failures on one particular /sup 60/Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of /sup 60/Co teletherapy units to minimise the results of the malfunctioning of such a system are given.

  4. Radiation incidents with a cobalt-60 teletherapy unit

    International Nuclear Information System (INIS)

    Lane, R.G.; Tolbert, D.D.; Pailwal, B.R.; Radtke, R.R.

    1976-01-01

    Three radiation incidents associated with source drive failures on one particular 60 Co teletherapy unit, which took place during a single year's operation, are discussed. In each case the extra treatment time of the patient, the exposure to the technician, the cause of the breakdown and the subsequent action taken are detailed. Recommendations for users of 60 Co teletherapy units to minimise the results of the malfunctioning of such a system are given. (U.K.)

  5. Dose enhancement in a room cobalt-60 source

    International Nuclear Information System (INIS)

    Simons, M.; Pease, R.L.; Fleetwood, D.M.; Schwank, J.R.; Krzesniak, M.

    1997-01-01

    A room Co-60 source was characterized using TLDs and pMOS RADFETs. Dose enhancement was measured using RADFETs with and without gold- flashed kovar lids. A methodology was developed to predict dose enhancement vs position and test configuration

  6. Reload of cobalt 60 for the J S-6500 irradiator

    International Nuclear Information System (INIS)

    Torres C, G.; Mayoral G, V.M.

    1991-01-01

    The present work has the purpose to describe the activities of the reloads program of the industrial irradiator J S-6500, elaborated for satisfying part of the demand of services and as a first step, to guide the decision making by the part of the ININ authorities in front of a wide market of this service. (Author)

  7. Dosemeter calibration in X-ray and in cobalt-60

    International Nuclear Information System (INIS)

    Silva, T.A. da

    1988-01-01

    Some tests about quality security for clinical dosemeter calibration in secondary standard dosimetry laboratory are described. The tests in gama calibration system, in X-ray calibration, in secondary standard dosimeter, in the dosemeter that will be calibrated, during the calibration and after the calibration are shown. (C.G.C.) [pt

  8. Sorption behaviour of cobalt-60 on Suez Canal bottom sediments

    International Nuclear Information System (INIS)

    Abdel Gawad, S.A.; El-Shinawy, R.M.K.; Abdel Malik, W.E.Y.

    1981-01-01

    Mineralogical, elemental analysis and sorption behaviour of the Suez Canal bottom sediments in the Port Said area were investigated. It was found that the bottom sediment consist mainly of quartz, feldspars and traces of calcite mineral. The cation-exchange capacity was found to increase as the particle size of the sediment decreased. Sorption of 60 Co by the bottom sediment increased with contact time up to 6 h. Variation of the solution pH from 4 to 9 showed limited increase in the sorption of 60 Co. As carrier concentrations increase from 10 -7 N to 10 -3 N, sorption of Co was found to increase linearly following Freundlich isotherm. The presence of Mg 2+ and Fe 3+ in solution depressed the sorption of 60 Co by the sediments. The desorption of 60 Co from bottom sediment with distilled and Suez Canal water was found to increase with contact time. (author)

  9. Overdevelopment tests in steel gammagraphy with cobalt 60 radiation

    International Nuclear Information System (INIS)

    Cinotti, C.; Cocoual, N.

    1985-01-01

    In the case of radiographic control of important thickness of steels, rapidity and image quality characteristics of overdeveloped radiographic films have been studied. Conditions have been fixed allowing to get a sensitive reduction of exposition times without modifying the radiogram quality [fr

  10. The Co{sup 60} Irradiation Facility and the Gamma Field at Riso; Appareil d'irradiation au cobalt-60 et champ sous irradiation gamma, a Riso; Ustanovka dlya obluchenij, rabotayushchaya na So60, i pole gamma-luchej v rizo; Instalacion de irradiacion con cobalto-60 y campo de irradiacion gamma en el centro de Riso

    Energy Technology Data Exchange (ETDEWEB)

    Brynjolfsson, A; Holm, N W [Danish Atomic Energy Commission, Establishment Riso (Denmark)

    1960-07-15

    The paper describes both the Co{sup 60} irradiation facility and the gamma field at the Agricultural Department of the Research Establishment, Riso. The Co{sup 60} irradiation facility contains 1,800 curies of Co{sup 60.} Details of the construction are given together with the safety precautions which have been included in the design. Dosimetry has been carried out by four different methods: 1. Ionisation chambers, 2. Calorimetry, 3. Fricke dosimeter, 4. Photographic films. A general outline is given of the gamma field, including details of source position. The dose rate is approximately 100 r./hr. at a distance of 1 m. An area of radius 15 m is used for the growing of plants under irradiation. A brief indication is given of the class of products which have been irradiated in the two facilities. (author) [French] Le memoire decrit l'appareil d'irradiation au cobalt-60 et le champ sous irradiation gamma du Departement de l'agriculture de l'Organisme de recherche de Riso. L'appareil d'irradiation au cobalt-60 contient une source de 1 800 curies. Des details sont donnes sur la construction ainsi que sur les dispositifs de protection compris dans le plan. Quatre methodes differentes ont ete utilisees pour la dosimetrie: 1. Chambres d'ionisation 2. Calorimetrie 3. Dosimetrie de Fricke 4. Pellicules photographique s On donne un apercu general du champ gamma, ainsi que des details sur la position de la source. L'intensite de dose est de 100 R/h environ a une distance de 1 m. Une zone d'un rayon de 15 m est utilisee pour la croissance des plantes soumises a l'irradiation. Des indications sommaires sont donnees sur la categorie des produits qui ont ete soumis a l'irradiation dans les deux installations. (author) [Spanish] Los autores describen la instalacion de irradiacion con cobalto-60 y el campo de irradiacion gamma del Departamento de Agronomia del Instituto de Investigaciones de Riso. El dispositivo de irradiacion consiste en una fuente de cobalto-60 de 1 800 curies

  11. The effect of illumination on gray color

    Directory of Open Access Journals (Sweden)

    Gabriele Sperandio

    2010-01-01

    Full Text Available The present study explored the perceptual process of integration of luminance information in the production of the gray color of an object placed in an environment viewed from a window. The mean luminance of the object was varied for each mean luminance of the environment. Participants matched the gray color of the object with that of Munsell chips in a viewing box. The results show that the Munsell values so obtained are linear measures of gray color. The results support the possibility that the gray color of the object derives from an additive integration of the information about mean luminance of the object and about mean luminance of the environment, with the weights of this information varying with the mean luminances.

  12. Electrochemical conversion of micropollutants in gray water

    NARCIS (Netherlands)

    Butkovskyi, A.; Jeremiasse, A.W.; Hernandez Leal, L.; Zande, van der T.; Rijnaarts, H.; Zeeman, G.

    2014-01-01

    Electrochemical conversion of micropollutants in real gray water effluent was studied for the first time. Six compounds that are frequently found in personal care and household products, namely methylparaben, propylparaben, bisphenol A, triclosan, galaxolide, and 4- methylbenzilidene camphor

  13. Laboratory Characterization of Gray Masonry Concrete

    National Research Council Canada - National Science Library

    Williams, Erin M; Akers, Stephen A; Reed, Paul A

    2007-01-01

    Personnel of the Geotechnical and Structures Laboratory, U.S. Army Engineer Research and Development Center, conducted a laboratory investigation to characterize the strength and constitutive property behavior of a gray masonry concrete...

  14. Re-irradiation with 36 Gy (1.5 Gy Twice Daily) Plus Paclitaxel for Advanced Recurrent and Previously Irradiated SCCHN is Feasible.

    Science.gov (United States)

    Rades, Dirk; Bartscht, Tobias; Idel, Christian; Hakim, Samer G

    2018-01-01

    Many patients developing a loco-regional recurrence of squamous cell carcinoma of head and neck (SCCHN) have a poor prognosis. Often, recurrences are unresectable, and patients require a second course of radiotherapy or chemoradiation. We present an approach of chemoradiation including mainly 30 Gy of radiotherapy (1.5 Gy twice daily) plus concurrent paclitaxel. To further improve the prognoses of these patients, we increased the radiation dose from 30 to 36 Gy. In four patients with recurrent and previously irradiated SCCHN (60-70 Gy) chemoradiation was carried out using 36 Gy (1.5 Gy twice daily) and concurrent paclitaxel (4-5 times 20-25 mg/m 2 ). One-year loco-regional control rates were 75% inside and 67% outside re-irradiated regions. One-year survival was 50%, and median survival time 11 months. Toxicities were mild (grade 0-2). Re-irradiation with 36 Gy (1.5 Gy twice daily) plus paclitaxel appears feasible and may lead to promising outcomes. This study is preceding a phase I trial. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  15. MQ-1C Gray Eagle Unmanned Aircraft System (MQ-1C Gray Eagle)

    Science.gov (United States)

    2015-12-01

    Range Finder /Laser Designator, Synthetic Aperture Radar/Ground Moving Target Indicator, communications relay, and Hellfire Missiles. Ground equipment...equipment strength . Each Gray Eagle company will consist of 125 soldiers within the Divisional CAB and the NTC. Each unit will have three identical...will bring these companies to full Gray Eagle System equipment strength . Each Gray Eagle company will consist of 125 soldiers within the divisional

  16. Gray matter alterations and correlation of nutritional intake with the gray matter volume in prediabetes

    OpenAIRE

    Hou, Yi-Cheng; Lai, Chien-Han; Wu, Yu-Te; Yang, Shwu-Huey

    2016-01-01

    Abstract The neurophysiology of prediabetes plays an important role in preventive medicine. The dysregulation of glucose metabolism is likely linked to changes in neuron-related gray matter. Therefore, we designed this study to investigate gray matter alterations in medication-naive prediabetic patients. We expected to find alterations in the gray matter of prediabetic patients. A total of 64 prediabetic patients and 54 controls were enrolled. All subjects received T1 scans using a 3-T magnet...

  17. Comparison of seed brachytherapy or external beam radiotherapy (70 Gy or 74 Gy) in 919 low-risk prostate cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Goldner, G.; Poetter, R.; Schmid, M.P.; Kirisits, C. [University Hospital of Vienna (Austria). Dept. of Radiotherapy and Radiobiology; Battermann, J.J.; Sljivic, S.; Vulpen, M. van [University Medical Center Utrecht (Netherlands). Dept. of Radiation Oncology

    2012-04-15

    The aim of this analysis was to compare the biochemical no evidence of disease (bNED) rates in low-risk prostate cancer patients treated at two centers of excellence using different approaches: seed brachytherapy (BT) and external beam radiotherapy (EBRT). Materials and methods: A total of 919 low-risk prostate cancer patients, treated from 1998-2008, were identified in the two databases. In Utrecht, 667 patients received I-125 BT applying a dose of 144 Gy. In Vienna, 252 patients were treated with EBRT, applying a local dose of 70 Gy in 82 patients and 74 Gy in 170 patients. bNED rates (Phoenix definition) were assessed. Results: The median follow-up was 46 months (range 1-148 months). The 5-year actuarial bNED rates were 94% for BT patients and 88% for EBRT patients (p = 0.002) - 84% for patients receiving 70 Gy and 91% for patients receiving 74 Gy, respectively. In the univariate analysis, patients receiving 70 Gy showed significantly worse outcome compared to BT (p = 0.001) and a difference close to significance compared to 74 Gy (p = 0.06). In the multivariate analysis including tumor stage, Gleason score, initial PSA, hormonal therapy, and dose, patients receiving 70 Gy EBRT showed significantly worse bNED rates compared to BT patients. Conclusion: Low-risk prostate cancer patients receiving 74 Gy by EBRT show comparable biochemical control rates to patients receiving seed brachytherapy, whereas patients receiving 70 Gy show significantly worse outcome. (orig.)

  18. Cost Comparison of Conventional Gray Combined Sewer Overflow Control Infrastructure versus a Green/Gray Combination

    Science.gov (United States)

    This paper outlines a life-cycle cost analysis comparing a green (rain gardens) and gray (tunnels) infrastructure combination to a gray-only option to control combined sewer overflow in the Turkey Creek Combined Sewer Overflow Basin, in Kansas City, MO. The plan area of this Bas...

  19. Gray matter heterotopias: MR and clinical features

    International Nuclear Information System (INIS)

    Moon, Tae Myung; Yoon, Jeong Hee; Chung, Chun Phil

    1995-01-01

    To evaluate types of gray matter heterotopias, associated brain anomalies, and its correlation with the patterns of seizure. We evaluated retrospectively 19 patients (male:female=10:9, mean age 21 years) with gray matter heterotopias on brain MRI. Using 1.0T superconducting MR unit, spin echo T1-, proton -density and T2-weighted images in axial, coronal and sagittal planes were obtained. Types of gray matter heterotopias were single subependymal in four patients, multiple subependymal in one, focal subcortical in eight, diffuse subcortical in two, mixed multiple subependymal and focal subcortical in four. Associated anomalies were seen in 11 patients: other neuronal migration anomalies in eight patients, corpus callosum agenesis in two, and combined holoprosencephaly and Dandy-Walker malformation in one. Fifteen patients had seizure. The patterns of seizure were not correlated with the types of heterotopias. In addition to subependymal, focal subcortical, and diffuse subcortical types, gray matter heterotopias included mixed variant of multiple subependymal and subcortical type. Schizencephaly was the most common form of accompanying anomalies, and patterns of seizure were not correlated with types of gray matter heterotopias, even though main clinical manifestation was seizure

  20. Acute and late complications after radiotherapy for prostate cancer: Results of a multicenter randomized trial comparing 68 Gy to 78 Gy

    International Nuclear Information System (INIS)

    Peeters, Stephanie T.H.; Heemsbergen, Wilma D.; Putten, Wim L.J. van; Slot, Annerie; Tabak, Hans; Mens, Jan Willem; Lebesque, Joos V.; Koper, Peter C.M.

    2005-01-01

    Purpose: To compare acute and late gastrointestinal (GI) and genitourinary (GU) side effects in prostate cancer patients randomized to receive 68 Gy or 78 Gy. Methods and materials: Between June 1997 and February 2003, 669 prostate cancer patients were randomized between radiotherapy with a dose of 68 Gy and 78 Gy, in 2 Gy per fraction and using three-dimensional conformal radiotherapy. All T stages with prostate-specific antigen (PSA) 120 days) was scored according to the slightly adapted RTOG/European Organization for Research and Treatment of Cancer (EORTC) criteria. Results: The median follow-up time was 31 months. For acute toxicity no significant differences were seen between the two randomization arms. GI toxicity Grade 2 and 3 was reported as the maximum acute toxicity in 44% and 5% of the patients, respectively. For acute GU toxicity, these figures were 41% and 13%. No significant differences between both randomization arms were seen for late GI and GU toxicity, except for rectal bleeding requiring laser treatment or transfusion (p = 0.007) and nocturia (p = 0.05). The 3-year cumulative risk of late RTOG/EORTC GI toxicity grade ≥2 was 23.2% for 68 Gy, and 26.5% for 78 Gy (p = 0.3). The 3-year risks of late RTOG/EORTC GU toxicity grade ≥2 were 28.5% and 30.2% for 68 Gy and 78 Gy, respectively (p = 0.3). Factors related to acute GI toxicity were HT (p < 0.001), a higher dose-volume group (p = 0.01), and pretreatment GI symptoms (p = 0.04). For acute GU toxicity, prognostic factors were: pretreatment GU symptoms (p < 0.001), HT (p = 0.003), and prior transurethral resection of the prostate (TURP) (p = 0.02). A history of abdominal surgery (p < 0.001) and pretreatment GI symptoms (p = 0.001) were associated with a higher incidence of late GI grade ≥2 toxicity, whereas HT (p < 0.001), pretreatment GU symptoms (p < 0.001), and prior TURP (p = 0.006) were prognostic factors for late GU grade ≥2. Conclusions: Raising the dose to the prostate from 68 Gy to

  1. Influence of neuraminidase and X-ray irradiation (2 Gy and 8 Gy) on microvilli and membrane invaginations of Ehrlich ascites tumor cells in monolayer culture

    International Nuclear Information System (INIS)

    Laudenbach, G.; Baganz, O.; Pfab, R.; Hess, F.; Schachtschabel, D.O.

    1987-01-01

    A monolayer culture (Eagle basal medium plus 10% of fetal calf serum) of Ehrlich ascites tumor cells was exposed to X-radiation with 2 Gy and 8 Gy and treated with Vibrio cholerae neuraminidase alone or combined with sublethal X-ray irradiation (2 Gy). Pictures of the Ehrlich ascites tumor cells taken with the electron microscope were investigated in order to find out any cell surface modifications due to membrane invaginations and microvilli. The results showed that the rate of microvilli as well as that of membrane invaginations became higher with the increasing X-ray dose (2 Gy; 8 Gy). Following to neuraminidase treatment there was a considerable augmentation of membran invaginations as compared to control cells, whereas the number of microvilli was slightly reduced. As it has been already described before, the influence of neuraminidase produced an increased endocytosis activity and a strengthening of the cytoskeleton. Combined treatment with neuraminidase and sublethal X-radiation (2 Gy) caused a higher rate of membrane invaginations than each method alone; the number of microvilli was slightly increased by combined treatment. The conclusion is drawn that these structure modifications are due to reparation processes induced by radiation on the one hand and to an enzymic action of neuraminidase on the cell surface on the other hand. (orig.) [de

  2. Gamma Radiation (5-10 Gy) Impairs Neuronal Function in the Guinea Pig Hippocampus

    Science.gov (United States)

    1993-01-01

    Radiation (5-10 Gy) Impairs Neuronal Function in the Guinea Pig Hippocampus TERRY C. PELLMAR AND DENNIS L. LEPINSKI Ph.vsiology Department..Irmned Forces...L. Gamma Radiation ioral effects. Within hours of irradiation with 10 Gy and (5- 10 Gy) Impairs Neuronal Function in the Guinea Pig Hippo- less...acti v- Guinea pigs were exposed to 5 and 10 Gy ’y radiation. Hippo- ity (9) are evident. campal brain slices were isolated 30 min, I day, 3 days and 5

  3. Comparison of 1 x 8 Gy and 10 x 3 Gy for functional outcome in patients with metastatic spinal cord compression

    Energy Technology Data Exchange (ETDEWEB)

    Rades, Dirk [Department of Radiation Oncology, University Hospital Hamburg-Eppendorf, Hamburg (Germany); Stalpers, Lukas J.A. [Department of Radiatiotherapy, Academic Medical Center, Amsterdam (Netherlands); Hulshof, Maarten C [Department of Radiatiotherapy, Academic Medical Center, Amsterdam (Netherlands); Borgmann, Kerstin [Department of Radiation Oncology, Section Radiobiology, University Hospital Hamburg-Eppendorf, Hamburg (Germany); Karstens, Johann H [Department of Radiation Oncology, Hannover Medical School, Hannover (Germany); Koning, Caro C.E. [Department of Radiatiotherapy, Academic Medical Center, Amsterdam (Netherlands); Alberti, Winfried [Department of Radiation Oncology, University Hospital Hamburg-Eppendorf, Hamburg (Germany)

    2005-06-01

    Purpose: Since life expectancy is markedly reduced in patients with metastatic spinal cord compression (MSCC), a short and effective radiation schedule is desired. This study investigates a reduction of the overall treatment time to only one day by comparing 1 x 8 Gy to the multi-fractionated 10 x 3 Gy for functional outcome. Methods and materials: Data of 204 patients, treated for MSCC with either 1 x 8 Gy (n = 96) or 10 x 3 Gy (n = 108), were analyzed retrospectively. Motor function and ambulatory status were evaluated before and up to 24 weeks after RT. A multivariate analysis (nominal regression) was performed including radiation schedule, performance status, age, irradiated vertebra, and relevant prognostic factors (histology, ambulatory status, time of developing motor deficits). Improvement of motor deficits was selected as basic category and compared with no change and deterioration. Results: Univariate analysis showed no significant difference between the schedules for post-treatment motor function and ambulatory rates. Multivariate analysis demonstrated a significant effect on functional outcome for the prognostic factors, but not for the radiation schedule (p = 0.853 for no change, p = 0.237 for deterioration). Conclusions: Our data suggest the two fractionation schedules to be comparably effective for functional outcome. Thus, 1 x 8 Gy should be considered for patients with a poor survival prognosis.

  4. Comparison of 1 x 8 Gy and 10 x 3 Gy for functional outcome in patients with metastatic spinal cord compression

    International Nuclear Information System (INIS)

    Rades, Dirk; Stalpers, Lukas J.A.; Hulshof, Maarten C.; Borgmann, Kerstin; Karstens, Johann H.; Koning, Caro C.E.; Alberti, Winfried

    2005-01-01

    Purpose: Since life expectancy is markedly reduced in patients with metastatic spinal cord compression (MSCC), a short and effective radiation schedule is desired. This study investigates a reduction of the overall treatment time to only one day by comparing 1 x 8 Gy to the multi-fractionated 10 x 3 Gy for functional outcome. Methods and materials: Data of 204 patients, treated for MSCC with either 1 x 8 Gy (n = 96) or 10 x 3 Gy (n = 108), were analyzed retrospectively. Motor function and ambulatory status were evaluated before and up to 24 weeks after RT. A multivariate analysis (nominal regression) was performed including radiation schedule, performance status, age, irradiated vertebra, and relevant prognostic factors (histology, ambulatory status, time of developing motor deficits). Improvement of motor deficits was selected as basic category and compared with no change and deterioration. Results: Univariate analysis showed no significant difference between the schedules for post-treatment motor function and ambulatory rates. Multivariate analysis demonstrated a significant effect on functional outcome for the prognostic factors, but not for the radiation schedule (p = 0.853 for no change, p = 0.237 for deterioration). Conclusions: Our data suggest the two fractionation schedules to be comparably effective for functional outcome. Thus, 1 x 8 Gy should be considered for patients with a poor survival prognosis

  5. Response to Biber, Gray, and Poonpon (2011)

    Science.gov (United States)

    Yang, WeiWei

    2013-01-01

    The recent "TESOL Quarterly" article by Biber, Gray, and Poonpon (2011) raises important considerations with respect to the use of syntactic complexity (SC) measures in second language (L2) studies. The article draws the field's attention to one particular measure--complexity of noun phrases (NP) (i.e., noun phrases with modifiers, such as…

  6. The Return to Gray Flannel Thinking.

    Science.gov (United States)

    Shields, James J., Jr.

    1979-01-01

    The liberal mood of the 1960s has given way to a conservatism reminiscent of the gray flannel thinking of the 1950s. Today's young people are cautious, cynical, and dead serious about personal survival. Innovation and liberalism in education are being replaced by fiscal conservatism and emphasis on standards. (Author/SJL)

  7. Chapter 17. Information needs: Great gray owls

    Science.gov (United States)

    Gregory D. Hayward

    1994-01-01

    Current understanding of great gray owl biology and ecology is based on studies of less than five populations. In an ideal world, a strong conservation strategy would require significant new information. However, current knowledge suggests that conservation of this forest owl should involve fewer conflicts than either the boreal or flammulated owl. The mix of forest...

  8. Hypothyroidism in children with medulloblastoma: a comparison of 3600 and 2340 cGy craniospinal radiotherapy

    International Nuclear Information System (INIS)

    Paulino, Arnold C.

    2002-01-01

    Purpose: To determine if low-dose craniospinal irradiation (2340 cGy) with chemotherapy is associated with a lower incidence of hypothyroidism compared to standard dose (3600 cGy) with or without chemotherapy in children with medulloblastoma. Patients and Methods: Between 1980 and 1999, 32 patients ≤20 years old survived after craniospinal irradiation with or without chemotherapy. Twenty patients received 3600 cGy craniospinal irradiation (CSI), whereas 12 had 2340 cGy CSI; all patients received a posterior fossa boost to a total dose 5040-5580 cGy. The median ages at the time of CSI for those receiving 2340 cGy and 3600 cGy were 7.2 and 10.2 years, respectively. Chemotherapy (CT) was employed in 22 children. All children who received 2340 cGy had CT consisting of vincristine, CCNU, and either cisplatin or cyclophosphamide. Ten of 20 (50%) patients receiving 3600 cGy had CT; the most common regimen was vincristine, CCNU, and prednisone. Serum-free thyroxine and thyroid-stimulating hormone concentrations were measured in all children at variable times after radiotherapy. Thyroid-stimulating hormone responses to i.v. thyrotrophin-releasing hormone were assessed in those suspected of having central hypothyroidism. Median follow-up for children receiving 2340 cGy was 5 years (range: 2-11.2 years), whereas for those receiving 3600 cGy, follow-up was 12.5 years (range: 2.4-20 years). Results: Eighteen patients (56%) developed hypothyroidism at a median time after radiotherapy of 41 months (range: 10 months to 18 years). Primary hypothyroidism was more common than central hypothyroidism (38% and 19%). All 7 children 10 years had hypothyroidism (p<0.001). Hypothyroidism was documented in 10 of 12 (83%) who had 2340 cGy + CT, 6 of 10 (60%) who had 3600 cGy + CT, and 2 of 10 (20%) who had 3600 cGy without CT (p<0.025). Conclusions: Current treatment regimens consisting of chemotherapy and 2340 cGy craniospinal irradiation followed by a posterior fossa boost for

  9. Multi-Institution Prospective Trial of Reduced-Dose Craniospinal Irradiation (23.4 Gy) Followed by Conformal Posterior Fossa (36 Gy) and Primary Site Irradiation (55.8 Gy) and Dose-Intensive Chemotherapy for Average-Risk Medulloblastoma

    International Nuclear Information System (INIS)

    Merchant, Thomas E.; Kun, Larry E.; Krasin, Matthew J.; Wallace, Dana; Chintagumpala, Murali M.; Woo, Shiao Y.; Ashley, David M.; Sexton, Maree; Kellie, Stewart J.; Ahern, Verity M.B.B.S.; Gajjar, Amar

    2008-01-01

    Purpose: Limiting the neurocognitive sequelae of radiotherapy (RT) has been an objective in the treatment of medulloblastoma. Conformal RT to less than the entire posterior fossa (PF) after craniospinal irradiation might reduce neurocognitive sequelae and requires evaluation. Methods and Materials: Between October 1996 and August 2003, 86 patients, 3-21 years of age, with newly diagnosed, average-risk medulloblastoma were treated in a prospective, institutional review board-approved, multi-institution trial of risk-adapted RT and dose-intensive chemotherapy. RT began within 28 days of definitive surgery and consisted of craniospinal irradiation (23.4 Gy), conformal PF RT (36.0 Gy), and primary site RT (55.8 Gy). The planning target volume for the primary site included the postoperative tumor bed surrounded by an anatomically confined margin of 2 cm that was then expanded with a geometric margin of 0.3-0.5 cm. Chemotherapy was initiated 6 weeks after RT and included four cycles of high-dose cyclophosphamide, cisplatin, and vincristine. Results: At a median follow-up of 61.2 months (range, 5.2-115.0 months), the estimated 5-year event-free survival and cumulative incidence of PF failure rate was 83.0% ± 5.3% and 4.9% ± 2.4% (± standard error), respectively. The targeting guidelines used in this study resulted in a mean reduction of 13% in the volume of the PF receiving doses >55 Gy compared with conventionally planned RT. The reductions in the dose to the temporal lobes, cochleae, and hypothalamus were statistically significant. Conclusion: This prospective trial has demonstrated that irradiation of less than the entire PF after 23.4 Gy craniospinal irradiation for average-risk medulloblastoma results in disease control comparable to that after treatment of the entire PF

  10. Synergistic effect of the combined treatment with gamma irradiation and sodium dichloroisocyanurate to control gray mold (Botrytis cinerea) on paprika

    International Nuclear Information System (INIS)

    Yoon, Minchul; Jung, Koo; Lee, Kwang-Youll; Jeong, Je-Yong; Lee, Ju-Woon; Park, Hae-Jun

    2014-01-01

    Gray mold (Botrytis cinerea) is one of the most major fungal pathogens in paprika. Generally, gamma irradiation over 1 kGy is effective for the control of fungal pathogens; however, a significant change in fruit quality (physical properties) on paprika was shown from gamma irradiation at over 0.6 kGy (p<0.05). Therefore, in this study, the synergistic disinfection effect of the combined treatment with gamma irradiation and sodium dichloroisocyanurate (NaDCC) was investigated to reduce the gamma irradiation dose. In an artificial inoculation experiment of B. cinerea isolated from naturally-infected postharvest paprika, fungal symptoms were observed in the stem and exocarp of paprika after conidial inoculation. From the sensitivity of gamma irradiation and NaDCC, B. cinerea conidia were fully inactivated by 4 kGy of gamma irradiation (D 10 value 0.99 kGy), and were fully inactivated by 50 ppm NaDCC treatment. The fungal symptoms were not detected by the dose-dependent gamma irradiation (>4 kGy) and NaDCC (>50 ppm). As a result of the combined treatment of gamma irradiation and NaDCC, the D 10 value was significantly reduced by 1.06, 0.88, 0.77, and 0.58 kGy (p<0.05). Moreover, fungal symptoms were more significantly reduced in combined treatment groups (gamma irradiation and NaDCC) than single treatment groups (gamma irradiation or NaDCC). These results suggest that combined treatment with irradiation and NaDCC treatment can be applied to preserve quality of postharvest paprika or other fruits. - Highlights: • Paprikas were treated with irradiation and NaDCC to control gray mold. • We confirmed that the combined treatment was synergistically affected. • The treatment can contribute to a reduction of postharvest losses caused by fungi. • This combined treatment can also reduce the doses of irradiation

  11. GY SAMPLING THEORY AND GEOSTATISTICS: ALTERNATE MODELS OF VARIABILITY IN CONTINUOUS MEDIA

    Science.gov (United States)

    In the sampling theory developed by Pierre Gy, sample variability is modeled as the sum of a set of seven discrete error components. The variogram used in geostatisties provides an alternate model in which several of Gy's error components are combined in a continuous mode...

  12. Preliminary results of a randomized trial comparing 400 cGy vs 700 cGy as an adjuvant to prevent heterotopic ossification after total hip arthroplasty

    International Nuclear Information System (INIS)

    Nguyen, Cam; Gupta-Burt, Shalina; Silverton, Craig; Cummings, Marilyn; Galante, Jorge O.

    1997-01-01

    Purpose/Objective: We report our preliminary results of a randomized trial comparing one single dose of 400 cGy versus 700 cGy given postoperatively in an attempt to prevent heterotopic ossification after total hip arthroplasty. Materials and Methods: From 09/1993 and 05/1996, over 800 total hip replacements were performed at our hospital. From this group of patients, 120 hips in 114 high-risk patients (14%) were enrolled in a randomized trial to determine if 400 cGy (Group A) is as efficacious as 700 cGy (Group B) in preventing heterotopic ossification. In Group A, there were 42 males (46 hips) and 12 females (12 hips) with a mean age of 60 (range 41-79); with 18 primary cementless femoral components (33%), 30 primary cemented stems (55%) and 10 revisions. In Group B, there were 30 males (32 hips) and 30 females (31 hips) with a median age of 59 (range 41-85); with 12 primary cementless femoral components (20%), 44 primary cemented stems (73%) and 6 revisions. All acetabular components were of the cementless type. Patients were randomized to receive either 400 cGy or 700 cGy in one fraction. Radiotherapy is given within 48 hours post-operatively using paired anterior and posterior fields, with blocking of the cementless acetabular component and the femoral component. Results: All 114 patients were available for a minimum follow-up of 6 months (range 6-30 months). None of the arthroplasties has failed at the latest follow-up. There were no radiation therapy complications noted. Statistical analysis revealed no difference in the distribution of patients in either group according to age, sex, primary or revision arthroplasty, cemented or cementless femoral component fixation, preoperative heterotopic ossification risk, or surgical approach. Of the 58 hips in Group A, heterotopic ossification was graded as Grade 0 in 24 hips, Grade I in 10 hips, Grade II in 18 hips, Grade III in 6 hips, with no cases of Grade IV. Of the 63 hips in Group B, heterotopic ossification was

  13. Gray matter alterations and correlation of nutritional intake with the gray matter volume in prediabetes

    Science.gov (United States)

    Hou, Yi-Cheng; Lai, Chien-Han; Wu, Yu-Te; Yang, Shwu-Huey

    2016-01-01

    Abstract The neurophysiology of prediabetes plays an important role in preventive medicine. The dysregulation of glucose metabolism is likely linked to changes in neuron-related gray matter. Therefore, we designed this study to investigate gray matter alterations in medication-naive prediabetic patients. We expected to find alterations in the gray matter of prediabetic patients. A total of 64 prediabetic patients and 54 controls were enrolled. All subjects received T1 scans using a 3-T magnetic resonance imaging machine. Subjects also completed nutritional intake records at the 24-hour and 3-day time points to determine their carbohydrate, protein, fat, and total calorie intake. We utilized optimized voxel-based morphometry to estimate the gray matter differences between the patients and controls. In addition, the preprandial serum glucose level and the carbohydrate, protein, fat, and total calorie intake levels were tested to determine whether these parameters were correlated with the gray matter volume. Prediabetic patients had lower gray matter volumes than controls in the right anterior cingulate gyrus, right posterior cingulate gyrus, left insula, left super temporal gyrus, and left middle temporal gyrus (corrected P prediabetic patients. PMID:27336893

  14. Premature graying of hair: An independent risk marker for coronary ...

    African Journals Online (AJOL)

    The presence of premature graying of hair was associated with 3.24 times the risk of CAD on multiple logistic regression analysis. CONCLUSION: The presence of premature graying of hair was associated with an increased risk of CAD in young smokers. Premature graying of hair can be used as preliminary evidence by ...

  15. Spine Radiosurgery: A Dosimetric Analysis in 124 Patients Who Received 18 Gy

    International Nuclear Information System (INIS)

    Schipani, Stefano; Wen, Winston; Jin, Jain-Yue; Kim, Jin Koo; Ryu, Samuel

    2012-01-01

    Purpose: To define the safely tolerated doses to organs at risk (OARs) adjacent to the target volume (TV) of spine radiosurgery (SRS) with 18-Gy in a single fraction. Methods and Materials: A total of 124 patient cases with 165 spine metastases were reviewed. An 18-Gy single-fraction regimen was prescribed to the 90% isodose line encompassing the TV. A constraint of 10 Gy to 10% of the spinal cord outlined 6 mm above and below the TV was used. Dosimetric data to OARs were analyzed. Results: A total of 124 patients (100%) were followed-up, and median follow-up time was 7 months (1-50 months). Symptoms and local control were achieved in 114 patients (92%). Acute Radiation Therapy Oncology Group (RTOG) grade 1 oral mucositis occurred in 11 of 11 (100%) patients at risk for oropharyngeal toxicity after cervical spine treatment. There were no RTOG grade 2-4 acute or late complications. Median TV was 43.2 cc (5.3-175.4 cc) and 90% of the TV received median dose of 19 Gy (17-19.8 Gy). Median (range) of spinal cord maximum dose (Dmax), dose to spinal cord 0.35 cc (Dsc0.35), and cord volume receiving 10 Gy (Vsc10) were 13.8 Gy (5.4-21 Gy), 8.9 Gy (2.6-11.4 Gy) and 0.33 cc (0-1.6 cc), respectively. Other OARs were evaluated when in proximity to the TV. Esophagus (n=58), trachea (n=28), oropharynx (n=11), and kidneys (n=34) received median (range) V10 and V15 of 3.1 cc (0-5.8 cc) and 1.2 cc (0-2.9 cc), 2.8 cc (0-4.9 cc), and 0.8 cc (0-2.1 cc), 3.4 cc (0-6.2 cc) and 1.6 cc (0-3.2 cc), 0.3 cc (0-0.8 cc) and 0.08 cc (0-0.1 cc), respectively. Conclusions: Cord Dmax of 14 Gy and D0.35 of 10 Gy are safe dose constraints for 18-Gy single-fraction SRS. Esophagus V10 of 3 cc and V15 of 1 cc, trachea V10 of 3 cc, and V15 of 1 cc, oropharynx V10 of 3.5 cc and V15 of 1.5 cc, kidney V10 of 0.3 cc, and V15 of 0.1 cc are planning guidelines when these OARs are in proximity to the TV.

  16. Increased Risk of Biochemical and Clinical Failure for Prostate Patients with a Large Rectum at Radiotherapy Planning: Results from the Dutch Trial of 68 GY Versus 78 Gy

    International Nuclear Information System (INIS)

    Heemsbergen, Wilma D.; Hoogeman, Mischa S.; Witte, Marnix G.; Peeters, Stephanie T.H.; Incrocci, Luca; Lebesque, Joos V.

    2007-01-01

    Purpose: To investigate whether a large rectum filling visible on the planning CT scan was associated with a decrease in freedom from any failure (FFF) and freedom from clinical failure (FFCF) for prostate cancer patients. Methods and Materials: Patients from the Dutch trial (78 Gy vs. 68 Gy) with available acute toxicity data were analyzed (n = 549). A 10-mm margin was applied for the first 68 Gy and 0-5 mm for the 10-Gy boost. The dose in the seminal vesicles (SVs) was prescribed within four treatment groups according to the estimated risk of SV involvement. Two potential risk factors (RFs) for a geometric miss were defined: (1) an anorectal volume ≥ 90 cm 3 and ≥ 25% of treatment-time diarrhea (RF1); and (2) the mean cross-sectional area of the anorectum (RF2). We tested whether these were significant predictors for FFF and FFCF within each treatment group. Results: Significant results were observed only for patients with a risk of SV involvement > 25% (dose of 68-78 Gy to the SVs, n = 349). We found a decrease in FFF (p = 0.001) and FFCF (p = 0.01) for the 87 patients with RF1 (for RF2, p = 0.02 and p = 0.01, respectively). The estimated decrease in the FFCF rate at 5 years was 15%. Conclusion: Tumor control was significantly decreased in patients with a risk of SV involvement > 25% and at risk of geometric miss. Current image guidance techniques offer several solutions to geometrically optimize the treatment. Additional research is needed to evaluate whether geometric misses can be prevented using these techniques

  17. Studies of the effect of 0.4-Gy and 0.6-Gy prenatal X-irradiation on postnatal adult behavior in the Wistar rat.

    Science.gov (United States)

    Jensh, R P; Brent, R L; Vogel, W H

    1987-02-01

    Thirty-four pregnant Wistar rats were X-irradiated on the 9th or 17th day of gestation at a dosage level 0.4 Gy or 0.6 Gy or were sham-irradiated. All mothers were allowed to deliver their offspring, and litters were limited to a maximum of eight on day 2. On day 30, 224 offspring were weaned and raised until 60 days of age, at which time testing began. Each rat randomly received, in random order, three of the following six behavioral tests: Water T-maze, Conditioned Avoidance Response, Forelimb Hanging, Activity Wheel, Swimming, and Open Field. There were no statistically significant differences between the irradiated and control groups for maternal weight or weight gain or mean litter size, although the litter size of the 17th day 0.6-Gy group was slightly lower. Among offspring irradiated with 0.6 Gy on the 17th day, 3-day-old neonates' weights were significantly reduced. Offspring irradiated on the 17th day with 0.6 Gy exhibited higher Conditioned Avoidance Response 5th-day and retest avoidance scores than did the controls. There were also significant sex differences in responses within the irradiated and control groups for several tests, which were unrelated to radiation exposure. The results of this study indicate that low-level X-irradiation during the fetal period of rat gestation results in neonatal growth retardation and subtle behavioral alterations that may be manifested in adult life. Growth retardation may be the most sensitive indicator of subtle effects that result from low-level prenatal exposure to X-rays.

  18. Studies of the effect of 0.4-Gy and 0.6-Gy prenatal X-irradiation on postnatal adult behavior in the Wistar rat

    International Nuclear Information System (INIS)

    Jensh, R.P.; Brent, R.L.; Vogel, W.H.

    1987-01-01

    Thirty-four pregnant Wistar rats were X-irradiated on the 9th or 17th day of gestation at a dosage level 0.4 Gy or 0.6 Gy or were sham-irradiated. All mothers were allowed to deliver their offspring, and litters were limited to a maximum of eight on day 2. On day 30, 224 offspring were weaned and raised until 60 days of age, at which time testing began. Each rat randomly received, in random order, three of the following six behavioral tests: Water T-maze, Conditioned Avoidance Response, Forelimb Hanging, Activity Wheel, Swimming, and Open Field. There were no statistically significant differences between the irradiated and control groups for maternal weight or weight gain or mean litter size, although the litter size of the 17th day 0.6-Gy group was slightly lower. Among offspring irradiated with 0.6 Gy on the 17th day, 3-day-old neonates' weights were significantly reduced. Offspring irradiated on the 17th day with 0.6 Gy exhibited higher Conditioned Avoidance Response 5th-day and retest avoidance scores than did the controls. There were also significant sex differences in responses within the irradiated and control groups for several tests, which were unrelated to radiation exposure. The results of this study indicate that low-level X-irradiation during the fetal period of rat gestation results in neonatal growth retardation and subtle behavioral alterations that may be manifested in adult life. Growth retardation may be the most sensitive indicator of subtle effects that result from low-level prenatal exposure to X-rays

  19. Delamination wear mechanism in gray cast irons

    International Nuclear Information System (INIS)

    Salehi, M.

    2000-01-01

    An investigation of the friction and sliding wear of gray cast iron against chromium plated cast irons was carried out on a newly constructed reciprocating friction and wear tester. The tests were the first to be done on the test rig under dry conditions and at the speed of 170 cm/min, and variable loads of 20-260 N for a duration of 15 min. to 3 hours. The gray cast iron surfaces worn by a process of plastic deformation at the subsurface, crack nucleation, and crack growth leading to formation of plate like debris and therefore the delamination theory applies. No evidence of adhesion was observed. This could be due to formation of oxides on the wear surface which prevent adhesion. channel type chromium plating ''picked'' up cast iron from the counter-body surfaces by mechanically trapping cast iron debris on and within the cracks. The removal of the plated chromium left a pitted surface on the cast iron

  20. Gray divorce: Explaining midlife marital splits.

    Science.gov (United States)

    Crowley, Jocelyn Elise

    2017-12-06

    Recent research suggests that one out of every four divorces in the United States is now "gray," meaning that at least one half of the couple has reached the age of 50 when the marriage breaks down. To understand why this age group-the Baby Boomer generation-is splitting up, this study conducted 40 in-depth, semistructured interviews with men and 40 with women who have experienced a gray divorce in their lifetimes. Respondents' beliefs in an expressive individualistic model of marriage, where partnerships are only valuable if they help individuals achieve personal growth, were compared against their potential adherence to what I call a commitment-based model of marriage, where binding, romantic love holds couples together unless there is severe relationship strain. The results demonstrated that the commitment-based model most strongly governs marriage and the decision to divorce among Baby Boomers for both sexes, although some specific reasons for divorce differ for men and women.

  1. Generative complexity of Gray-Scott model

    Science.gov (United States)

    Adamatzky, Andrew

    2018-03-01

    In the Gray-Scott reaction-diffusion system one reactant is constantly fed in the system, another reactant is reproduced by consuming the supplied reactant and also converted to an inert product. The rate of feeding one reactant in the system and the rate of removing another reactant from the system determine configurations of concentration profiles: stripes, spots, waves. We calculate the generative complexity-a morphological complexity of concentration profiles grown from a point-wise perturbation of the medium-of the Gray-Scott system for a range of the feeding and removal rates. The morphological complexity is evaluated using Shannon entropy, Simpson diversity, approximation of Lempel-Ziv complexity, and expressivity (Shannon entropy divided by space-filling). We analyse behaviour of the systems with highest values of the generative morphological complexity and show that the Gray-Scott systems expressing highest levels of the complexity are composed of the wave-fragments (similar to wave-fragments in sub-excitable media) and travelling localisations (similar to quasi-dissipative solitons and gliders in Conway's Game of Life).

  2. Regional gray matter correlates of vocational interests.

    Science.gov (United States)

    Schroeder, David H; Haier, Richard J; Tang, Cheuk Ying

    2012-05-16

    Previous studies have identified brain areas related to cognitive abilities and personality, respectively. In this exploratory study, we extend the application of modern neuroimaging techniques to another area of individual differences, vocational interests, and relate the results to an earlier study of cognitive abilities salient for vocations. First, we examined the psychometric relationships between vocational interests and abilities in a large sample. The primary relationships between those domains were between Investigative (scientific) interests and general intelligence and between Realistic ("blue-collar") interests and spatial ability. Then, using MRI and voxel-based morphometry, we investigated the relationships between regional gray matter volume and vocational interests. Specific clusters of gray matter were found to be correlated with Investigative and Realistic interests. Overlap analyses indicated some common brain areas between the correlates of Investigative interests and general intelligence and between the correlates of Realistic interests and spatial ability. Two of six vocational-interest scales show substantial relationships with regional gray matter volume. The overlap between the brain correlates of these scales and cognitive-ability factors suggest there are relationships between individual differences in brain structure and vocations.

  3. Gray rod for a nuclear reactor

    International Nuclear Information System (INIS)

    Francis, T.A.; Cerni, Samuel.

    1986-01-01

    The invention relates to an improved gray rod for insertion in a nuclear fuel assembly having an array of fuel rods. The gray rod includes a thin-walled cladding tube a first longitudinal section of which is positioned within, and a second longitudinal section of which is positioned essentially without, the array of fuel rods when the gray rod is inserted in the fuel assembly. The first longitudinal section defines a pellet-receiving space having detained therein a stack of annular pellets with an outer diameter sufficient to lend radial support to the wall of the first longitudinal tube section. The second longitudinal section defines a hollow space devoid of pellets and having means to resist radial collapse under external pressure. This means may be a partially compressed spiral spring which serves the dual purpose of retaining the stack of pellets in the pellet-receiving space and of lending radial support to the wall of the second longitudinal tube section or it may be holes through the wall to allow pressure equalisation. The cladding tube is composed of stainless-steel material having a low neutron-capture cross-section, and the annular pellets preferably being composed of Zircaloy or Zirconia material. (author)

  4. 20 Gy Versus 44 Gy of Supplemental External Beam Radiotherapy With Palladium-103 for Patients With Greater Risk Disease: Results of a Prospective Randomized Trial

    International Nuclear Information System (INIS)

    Merrick, Gregory S.; Wallner, Kent E.; Butler, Wayne M.; Galbreath, Robert W.; Taira, Al V.; Orio, Peter; Adamovich, Edward

    2012-01-01

    Purpose: The necessity of external beam radiotherapy (EBRT) as a supplement to prostate brachytherapy remains unknown. We report brachytherapy outcomes for patients with higher risk features randomized to substantially different supplemental EBRT regimens. Methods and Materials: Between December 1999 and June 2004, 247 patients were randomized to 20 Gy vs. 44 Gy EBRT followed by a palladium-103 boost (115 Gy vs. 90 Gy). The eligibility criteria included clinically organ-confined disease with Gleason score 7–10 and/or pretreatment prostate-specific antigen (PSA) level 10–20 ng/mL. The median follow-up period was 9.0 years. Biochemical progression-free survival (bPFS) was defined as a PSA level of ≤0.40 ng/mL after nadir. The median day 0 prescribed dose covering 90% of the target volume was 125.7%; 80 men received androgen deprivation therapy (median, 4 months). Multiple parameters were evaluated for their effect on bPFS. Results: For the entire cohort, the cause-specific survival, bPFS, and overall survival rates were 97.7%, 93.2%, and 80.8% at 8 years and 96.9%, 93.2%, and 75.4% at 10 years, respectively. The bPFS rate was 93.1% and 93.4% for the 20-Gy and 44-Gy arms, respectively (p = .994). However, no statistically significant differences were found in cause-specific survival or overall survival were identified. When stratified by PSA level of ≤10 ng/mL vs. >10 ng/mL, Gleason score, or androgen deprivation therapy, no statistically significant differences in bPFS were discerned between the two EBRT regimens. On multivariate analysis, bPFS was most closely related to the preimplant PSA and clinical stage. For patients with biochemically controlled disease, the median PSA level was <0.02 ng/mL. Conclusion: The results of the present trial strongly suggest that two markedly different supplemental EBRT regimens result in equivalent cause-specific survival, bPFS, and overall survival. It is probable that the lack of benefit for a higher supplemental EBRT

  5. Study of L-aspartic acid for its possible use as a dosimeter in the interval of 3.4-20 kGy at different irradiation temperatures

    Science.gov (United States)

    Meléndez-López, Adriana; Negrón-Mendoza, Alicia; Gómez-Vidales, Virginia; Uribe, Roberto M.; Ramos-Bernal, Sergio

    2014-11-01

    Certain commercial applications of radiation processing increase the efficiency of chemical reactions at low temperatures to decrease the free radicals in the bulk material and avoid the synergistic effects of heat. Such applications have motivated the search for a reliable, low-temperature dosimeter for use under the conditions of the irradiation process. For this purpose, polycrystalline samples of L-aspartic acid (2-aminobutanedioic acid) were irradiated with gamma rays at low temperatures and doses in the kiloGray range (3.4-64 kGy). The potential use of the aspartic acid system as a chemical dosimeter is based on the formation of stable free radicals when the amino acid is exposed to ionizing radiation. These radicals can be studied and quantified using electron spin resonance (ESR). The response curves at different temperatures show that the intensity of the ESR spectra (the five characteristic lines) depends on the dose received. The response of the dosimeter increases with increasing temperature, and this relationship is linear up to 20 kGy at 298 K. The decay characteristics show that the change in the ESR signal over time is low and reproducible. In addition, the L-aspartic acid dosimeter is easy to handle and has low cost.

  6. Information fusion for the Gray Zone

    Science.gov (United States)

    Fenstermacher, Laurie

    2016-05-01

    United States Special Operations Command (SOCOM) recently published a white paper describing the "Gray Zone", security challenges characterized by "ambiguity about the nature of the conflict, opacity of the parties involved…competitive interactions among and within state and non-state actors that fall between the traditional war and peace duality."1 Ambiguity and related uncertainty about actors, situations, relationships, and intent require new approaches to information collection, processing and fusion. General Votel, the current SOCOM commander, during a recent speech on "Operating in the Gray Zone" emphasized that it would be important to get left of the next crises and stated emphatically, "to do that we must understand the Human Domain."2 This understanding of the human domain must come from making meaning based on different perspectives, including the "emic" or first person/participant and "etic" or third person/observer perspectives. Much of the information currently collected and processed is etic. Incorporation and fusion with the emic perspective enables forecasting of behaviors/events and provides context for etic information (e.g., video).3 Gray zone challenges are perspective-dependent; for example, the conflict in Ukraine is interpreted quite differently by Russia, the US and Ukraine. Russia views it as war, necessitating aggressive action, the US views it as a security issue best dealt with by economic sanctions and diplomacy and the Ukraine views it as a threat to its sovereignty.4 General Otto in the Air Force ISR 2023 vision document stated that Air Force ISR is needed to anticipate strategic surprise.5 Anticipatory analysis enabling getting left of a crisis inherently requires a greater focus on information sources that elucidate the human environment as well as new methods that elucidate not only the "who's" and "what's", but the "how's and "why's," extracting features and/or patterns and subtle cues useful for forecasting behaviors and

  7. Gray Zone Legislation and Activities: Evaluating the Orchestration of Convergence Within the Gray Zone

    Science.gov (United States)

    2017-06-01

    The Agency and the Hill (Government Printing Office, 2008), 8. 16 Lowenthal, Intelligence . 17 Marshall Erwin, Covert Action: Legislative Background...military and intelligence activities within the Gray Zone and what directs their convergence. More specifically, the author analyzes the...determining convergence or divergence. In the end, classical military theory directs the convergence and divergence of military and intelligence activities

  8. Effects of nano bamboo charcoal on PAHs-degrading strain Sphingomonas sp. GY2B.

    Science.gov (United States)

    She, Bojia; Tao, Xueqin; Huang, Ting; Lu, Guining; Zhou, Zhili; Guo, Chuling; Dang, Zhi

    2016-03-01

    Nano bamboo charcoal (NBC) has been commonly used in the production of textiles, plastics, paint, etc. However, little is known regarding their effects towards the microorganisms. The effects of NBC on phenanthrene degrading strain Sphingomonas sp. GY2B were investigated in the present study. Results showed that the addition of NBC could improve the phenanthrene removal by Sphingomonas sp. GY2B, with removal efficiencies increased by 10.29-18.56% in comparison to the control at 24h, and phenanthrene was almost completely removed at 48h. With the presence of low dose of NBC (20 and 50mgL(-1)), strain GY2B displayed a better growth at 6h, suggesting that NBC was beneficial to the growth of GY2B and thus resulting in the quick removal of phenanthrene from water. However, the growth of strain GY2B in high dose of NBC (200mgL(-1)) was inhibited at 6h, and the inhibition could be attenuated and eliminated after 12h. NBC-effected phenanthrene solubility experiment suggested that NBC makes a negligible contribution to the solubilization of phenanthrene in water. Results of electronic microscopy analysis (SEM and TEM) indicated NBC may interact with the cell membrane, causing the enhanced membrane permeability and then NBC adsorbed on the membrane would enter into the cells. The findings of this work would provide important information for the future usage and long-term environmental risk assessment of NBC. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. PET MRI Coregistration in Intractable Epilepsy and Gray Matter Heterotopia.

    Science.gov (United States)

    Seniaray, Nikhil; Jain, Anuj

    2017-03-01

    A 25-year-old woman with intractable seizures underwent FDG PET/MRI for seizure focus localization. MRI demonstrated bilateral carpetlike nodular subependymal gray matter and asymmetrical focal dilatation in the right temporal horn. PET/MRI showed increased FDG within subependymal gray matter with significant hypometabolism in right anterior temporal lobe. EEG and ictal semiology confirmed the right temporal seizure origin. This case highlights the importance of identification of gray matter heterotopia on FDG PET/MRI.

  10. Dichromatic Gray Pixel for Camera-agnostic Color Constancy

    OpenAIRE

    Qian, Yanlin; Chen, Ke; Nikkanen, Jarno; Kämäräinen, Joni-Kristian; Matas, Jiri

    2018-01-01

    We propose a novel statistical color constancy method, especially suitable for the Camera-agnostic Color Constancy, i.e. the scenario where nothing is known a priori about the capturing devices. The method, called Dichromatic Gray Pixel, or DGP, relies on a novel gray pixel detection algorithm derived using the Dichromatic Reflection Model. DGP is suitable for camera-agnostic color constancy since varying devices are set to make achromatic pixels look gray under standard neutral illumination....

  11. Randomized Comparison of Whole Brain Radiotherapy, 20 Gy in Four Daily Fractions Versus 40 Gy in 20 Twice-Daily Fractions, for Brain Metastases

    International Nuclear Information System (INIS)

    Graham, P.H.; Bucci, J.; Browne, L.

    2010-01-01

    Purpose: The present study compared the intracranial control rate and quality of life for two radiation fractionation schemes for cerebral metastases. Methods and Materials: A total of 113 patients with a Eastern Cooperative Oncology Group performance status 2 months), absent, or concurrent presentation of extracranial disease were randomized to 40 Gy in 20 twice-daily fractions (Arm A) or 20 Gy in four daily fractions (Arm B), stratified by resection status. The European Organization for Research and Treatment of Cancer Quality of Life 30-item questionnaire was administered monthly during Year 1, bimonthly during Year 2, and then every 6 months to Year 5. Results: The patient age range was 28-83 years (mean 62). Of the 113 patients, 41 had undergone surgical resection, and 74 patients had extracranial disease (31 concurrent and 43 stable). The median survival time was 6.1 months in Arm A and 6.6 months in Arm B, and the overall 5-year survival rate was 3.5%. Intracranial progression occurred in 44% of Arm A and 64% of Arm B patients (p = .03). Salvage surgery or radiotherapy was used in 4% of Arm A patients and 21% of Arm B patients (p = .004). Death was attributed to central nervous system progression in 32% of patients in Arm A and 52% of patients in Arm B (p = .03). The toxicity was minimal, with a minor increase in short-term cutaneous reactions in Arm A. The patients' quality of life was not impaired by the more intense treatment in Arm A. Conclusion: Intracranial disease control was improved and the quality of life was maintained with 40 Gy in 20 twice-daily fractions. This schema should be considered for better prognosis subgroups of patients with cerebral metastases.

  12. The greenhouse effect in a gray planetary atmosphere.

    Science.gov (United States)

    Wildt, R.

    1966-01-01

    Hopf analytical solution for values of ratio of gray absorption coefficients for insolating and escaping radiation /greenhouse parameter/ assumed constant at all depths, presenting temperature distribution graphs

  13. ESR dosimetry below 1 Gy, in X-ray irradiated tooth enamel

    International Nuclear Information System (INIS)

    Fainstein, Carlos; Winkler, Elin

    2000-01-01

    Tooth enamel, extracted from molars, was irradiated with 66 keV X-rays, with doses up to 1 Gy. The preparation of the powder samples is described, as well as the protocol for the acquisition and processing of the spectra. The radiation induced paramagnetism is measured, at room temperature, by ESR Spectroscopy. The ESR spectra is well described considering two paramagnetic species, with magnetic moments (in units of Bohr magneton) g=2,0041, and g 1 =2,0018, g 2 =1,9972. The ESR data (peak-to-peak amplitude per mg, hpp/mg, vs dose D), for doses 0 Gy 2 =0,996) with the linear expression: [hpp/mg] = -0,2(0,4)+14,9(0,5). D [Gy]. The result supports the growing confidence in the use of this material, and method, in Retrospective Dosimetry. (author)

  14. ESR Dosimetry Below 1 Gy, in X-Ray Irradiated Tooth Enamel

    International Nuclear Information System (INIS)

    Fainstein, Carlos; Winkler, E; Dubner, D; Gisone, P; Perez, M.R; Saravi, M; Alvarez, P; Davila, F

    2000-01-01

    Tooth enamel, extracted from molars, was irradiated with 66keV X-rays, with doses up to 1Gy.The preparation of the powder samples is described, as well as the protocol for the acquisition and processing of the spectra.The radiation induced paramagnetism is measured, at room temperature, by ESR Spectroscopy.The ESR spectra is well described considering two paramagnetic species, with magnetic moments (in units of Bohr magnetons) g=2,0041, and g1=2,0018, g2=1,9972.The ESR data (peak-to-peak amplitude per mg, hpp/mg, vs dose D), for doses 0Gy 2 =0,996) with the linear expression: [hpp/mg] = -0,2( 0,4)+14,9(0,5). D [Gy].The result supports the growing confidence in the use of this material, and method, in Retrospective Dosimetry

  15. 哈氏弧菌EcGY020401优化培养%Optimization Culture of Vibrio harveyi EcGY020401

    Institute of Scientific and Technical Information of China (English)

    陶家发; 赖迎迢; 潘厚军; 石存斌; 吴淑勤

    2010-01-01

    目的:为规模化制备弧菌疫苗提供相关数据.方法:利用摇瓶和小型发酵罐培养,通过平板计数测定培养菌液的活菌数.结果:哈氏弧菌(Vibrio harveyi)EcGY020401株最适盐度为20~25g/L,合适的pH为7.5~7.7,葡萄糖浓度最适浓度为2~5g/L,用TSB优化培养基:胰蛋白胨5g/L、蛋白胨15g/L、大豆蛋白胨3g/L、酵母膏1g/L、葡萄糖4g/L、磷酸氢二钾5g/L、氯化钠15g/L、pH 7.5,培养EcGY020401菌株,可达2.95×1010 cfu/mL;小型发酵罐培养,10h可达到生长最大值,菌液浓度为3.46×1010cfu/mL 结论:用优化TSB培养基,采用发酵罐培养弧菌,可降低成本,提搞培养效率.

  16. Aberrant paralimbic gray matter in criminal psychopathy.

    Science.gov (United States)

    Ermer, Elsa; Cope, Lora M; Nyalakanti, Prashanth K; Calhoun, Vince D; Kiehl, Kent A

    2012-08-01

    Psychopaths impose large costs on society, as they are frequently habitual, violent criminals. The pervasive nature of emotional and behavioral symptoms in psychopathy suggests that several associated brain regions may contribute to the disorder. Studies employing a variety of methods have converged on a set of brain regions in paralimbic cortex and limbic areas that appear to be dysfunctional in psychopathy. The present study further tests this hypothesis by investigating structural abnormalities using voxel-based morphometry in a sample of incarcerated men (N=296). Psychopathy was associated with decreased regional gray matter in several paralimbic and limbic areas, including bilateral parahippocampal, amygdala, and hippocampal regions, bilateral temporal pole, posterior cingulate cortex, and orbitofrontal cortex. The consistent identification of paralimbic cortex and limbic structures in psychopathy across diverse methodologies strengthens the interpretation that these regions are crucial for understanding neural dysfunction in psychopathy. PsycINFO Database Record (c) 2012 APA, all rights reserved.

  17. Effect of 30-Gy irradiation in conjunction with leukocyte reduction filter on platelet and transfusion efficiency

    International Nuclear Information System (INIS)

    Shimojima, Hiromi; Sawada, Umihiko; Horie, Takashi; Itoh, Takeyoshi

    2001-01-01

    To evaluate the effect of 30-Gy irradiation in conjunction with leukocyte reduction filter on platelet and transfusion efficiency, we studied platelet recovery, leukocyte reduction rate, content of platelet factor 4 and β-thromboglobulin in platelet products, platelet functions, and positive rates of platelet surface membranes CD42 and CD62, prior to and after treatment. We also evaluated the efficiency of platelet transfusion by estimating post- transfusion (1 and 24 hour) corrected count increment (CCI), and transfusion side effects. Recovery of platelets was 91.8±6.5% and depletion rate of leukocytes was 1.7±1.1 log. There was no significant difference in platelet activation markers or function tests prior to and after the procedure. The mean post-transfusion CCI and 1 and 24 hours were 16,550 (n=114) and 13,310 (n=93), respectively, with 30-Gy irradiation and leukocyte reduction filter. Those treated solely with leukocyte reduction filter were 14,970 (n=114) and 10,880 (n=118), respectively. There was no increase in transfusion side effects after the treatment of platelet concentrate with 30-Gy irradiation combined with leukocyte reduction filter compared with treatment by leukocyte reduction filter alone. These results indicate that treatment with 30 Gy irradiation in conjunction with leukocyte reduction filter is safe and effective in platelet transfusion. (author)

  18. Underwater Image Enhancement by Adaptive Gray World and Differential Gray-Levels Histogram Equalization

    Directory of Open Access Journals (Sweden)

    WONG, S.-L.

    2018-05-01

    Full Text Available Most underwater images tend to be dominated by a single color cast. This paper presents a solution to remove the color cast and improve the contrast in underwater images. However, after the removal of the color cast using Gray World (GW method, the resultant image is not visually pleasing. Hence, we propose an integrated approach using Adaptive GW (AGW and Differential Gray-Levels Histogram Equalization (DHE that operate in parallel. The AGW is applied to remove the color cast while DHE is used to improve the contrast of the underwater image. The outputs of both chromaticity components of AGW and intensity components of DHE are combined to form the enhanced image. The results of the proposed method are compared with three existing methods using qualitative and quantitative measures. The proposed method increased the visibility of underwater images and in most cases produces better quantitative scores when compared to the three existing methods.

  19. From nGy to MGy - new TL dosimetry of complex radiation at high-energy accelerators and thermonuclear fusion facilities

    International Nuclear Information System (INIS)

    Obryk, B.; Bilski, P.; Budzanowski, M.; Olko, P.

    2011-01-01

    One of the well known advantages of thermoluminescence (TL) detectors made of lithium fluoride doped with magnesium, copper and phosphorus (LiF:Mg,Cu,P) is their very high sensitivity to ionizing radiation. LiF:Mg,Cu,P detectors enable measurements of radiation doses from tens of nano grays up to a few kilo grays, when the total saturation of the signal of the so-called main dosimetric peak (at about 220 C. degrees) occurs. In 2006 for the first time we observed unprecedented high-temperature emission of LiF detectors heated to temperatures up to 600 C. degrees, after exposures to radiation doses ranging from 1 kGy to 1 MGy. For quantification of the glow curve shape changes of LiF:Mg,Cu,P detectors in this range of doses and determination of the absorbed dose, the high temperature coefficient (UHTR) was defined. This newly established dosimetric method was tested in a range of radiation qualities, such as gamma radiation, electron and proton beams, thermal neutron fields and in high-energy mixed fields around the SPS and PS accelerators at CERN. A number of dosimetric sets with LiF:Mg,Cu,P detectors are currently installed around the LHC at CERN. The new method for ultra-high dose range monitoring with a single LiF:Mg,Cu,P detector, which is capable of covering at least twelve orders of magnitude of doses, can be used for dosimetry at high energy accelerators and has great potential for accident dosimetry in particular. (authors)

  20. Gray literature: An important resource in systematic reviews.

    Science.gov (United States)

    Paez, Arsenio

    2017-08-01

    Systematic reviews aide the analysis and dissemination of evidence, using rigorous and transparent methods to generate empirically attained answers to focused research questions. Identifying all evidence relevant to the research questions is an essential component, and challenge, of systematic reviews. Gray literature, or evidence not published in commercial publications, can make important contributions to a systematic review. Gray literature can include academic papers, including theses and dissertations, research and committee reports, government reports, conference papers, and ongoing research, among others. It may provide data not found within commercially published literature, providing an important forum for disseminating studies with null or negative results that might not otherwise be disseminated. Gray literature may thusly reduce publication bias, increase reviews' comprehensiveness and timeliness, and foster a balanced picture of available evidence. Gray literature's diverse formats and audiences can present a significant challenge in a systematic search for evidence. However, the benefits of including gray literature may far outweigh the cost in time and resource needed to search for it, and it is important for it to be included in a systematic review or review of evidence. A carefully thought out gray literature search strategy may be an invaluable component of a systematic review. This narrative review provides guidance about the benefits of including gray literature in a systematic review, and sources for searching through gray literature. An illustrative example of a search for evidence within gray literature sources is presented to highlight the potential contributions of such a search to a systematic review. Benefits and challenges of gray literature search methods are discussed, and recommendations made. © 2017 Chinese Cochrane Center, West China Hospital of Sichuan University and John Wiley & Sons Australia, Ltd.

  1. Detection of sub micro Gray dose levels using OSL phosphor LiMgPO_4:Tb,B

    International Nuclear Information System (INIS)

    Rawat, N.S.; Dhabekar, Bhushan; Muthe, K.P.; Koul, D.K.; Datta, D.

    2017-01-01

    Highlights: • LiMgPO4:Tb,B has been studied and shown to possesses minimum measurable dose (MMD) in sub micro Gray region. • MMD as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm"2 has been achieved. • The OSL measurements for low doses has strengthened and validated this claim. • OSL spectrum shows several emission peaks and the prominent peak around 380 nm. - Abstract: Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO_4:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb"3"+ emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW–) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm"2 has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.

  2. Detection of sub micro Gray dose levels using OSL phosphor LiMgPO{sub 4}:Tb,B

    Energy Technology Data Exchange (ETDEWEB)

    Rawat, N.S., E-mail: naru@barc.gov.in [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Dhabekar, Bhushan [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Muthe, K.P. [Technical Physics Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India); Koul, D.K.; Datta, D. [Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai (India)

    2017-04-15

    Highlights: • LiMgPO4:Tb,B has been studied and shown to possesses minimum measurable dose (MMD) in sub micro Gray region. • MMD as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm{sup 2} has been achieved. • The OSL measurements for low doses has strengthened and validated this claim. • OSL spectrum shows several emission peaks and the prominent peak around 380 nm. - Abstract: Detection of sub micro Gray doses finds application in personnel and environmental monitoring, and nuclear forensics. Recently developed LiMgPO{sub 4}:Tb,B (LMP) is highly sensitive Optically Stimulated Luminescence (OSL) phosphor with excellent dosimetric properties. The OSL emission spectrum of LMP consists of several peaks attributed to characteristic Tb{sup 3+} emission. The OSL emission peak at 380 nm is favorable for bi-alkali PMT used in RISO reader system. It is demonstrated that significant improvement in dose detection threshold can be realized for LMP by optimization of continuous wave (CW–) OSL parameters like stimulation intensity and readout time. The minimum measurable dose (MMD) as low as 0.49 µGy in readout time of less than 1 s at stimulation intensity of 32 mW/cm{sup 2} has been achieved using this phosphor. The recommendations for choice of parameters for personnel and environmental monitoring are also discussed.

  3. 125I Monotherapy Using D90 Implant Doses of 180 Gy or Greater

    International Nuclear Information System (INIS)

    Kao, Johnny; Stone, Nelson N.; Lavaf, Amir; Dumane, Vishruta; Cesaretti, Jamie A.; Stock, Richard G.

    2008-01-01

    Purpose: The purpose of this study was to characterize the oncologic results and toxicity profile of patients treated with 125 I implants using the dose delivered to 90% of the gland from the dose-volume histogram (D90) of greater than 144 Gy. Methods and Materials: From June 1995 to Feb 2005, a total of 643 patients were treated with 125 I monotherapy for T1-T2 prostate cancer with a D90 of 180 Gy or greater (median, 197 Gy; range, 180-267 Gy). Implantations were performed using a real-time ultrasound-guided seed-placement method and intraoperative dosimetry to optimize target coverage and homogeneity by using modified peripheral loading. We analyzed biochemical disease-free survival (bDFS) of 435 patients who had a minimum 2-year prostate-specific antigen follow-up (median follow-up, 6.7 years; range, 2.0-11.1 years). Results: Five-year bDFS rates for the entire cohort using the American Society for Therapeutic Radiology and Oncology and Phoenix definitions were 96.9% and 96.5%, respectively. Using the Phoenix definition, 5-year bDFS rates were 97.3% for low-risk patients and 92.8% for intermediate/high-risk patients. The positive biopsy rate was 4.1%. The freedom rate from Grade 2 or higher rectal bleeding at 5 years was 88.5%. Acute urinary retention occurred in 10.7%, more commonly in patients with high pretreatment International Prostate Symptom Scores (p < 0.01). In patients who were potent before treatment, 73.4% remained potent at 5 years after implantation. Conclusions: Patients with a minimum D90 of 180 Gy had outstanding local control based on prostate-specific antigen control and biopsy data. Toxicity profiles, particularly for long-term urinary and sexual function, were excellent and showed that D90 doses of 180 Gy or greater performed using the technique described were feasible and tolerable

  4. Moving Beyond IGY: An Electronic Geophysical Year (eGY) Concept

    Science.gov (United States)

    Baker, D. N.; Barton, C. E.; Rodger, A. S.; Thompson, B. J.; Fraser, B.; Papitashvili, V.

    2003-12-01

    During the International Geophysical Year (1957-1958), member countries established many new geophysical observatories pursuing the major IGY objectives - to collect geophysical data as widely as possible and to provide free access to these data for all scientists around the globe. Today, geophysics has attained a rather good understanding within traditional regions, i.e., the atmosphere, ionosphere, magnetosphere, and other such geospheres. At the same time, it has become clear that much of the new and important science is coming from the studies of interfaces and coupling between geospheres. Thus, if geophysical data are made `'transparently'' available to a much wider range of scientists and students than to those who do the observations, then new and exciting discoveries can be expected. An International Association of Geomagnetic and Aeronomy (IAGA) task force, recognizing that a key achievement of the IGY was the establishment of a worldwide system of data centers and physical observatories, proposes that for the 50th anniversary of IGY, the worldwide scientific community should endorse and promote an electronic Geophysical Year (eGY) initiative. The proposed eGY concept would both commemorate the IGY in 2007-2008 and provide a forward impetus to geophysics in 21st century, similar to that provided by the IGY fifty years ago. The IAGA task force strongly advocates: (1) Securing permission and release of existing data; (2) Creating access to information; and (3) Conversion of relevant analog data to digital form. The eGY concept embraces all available and upcoming geophysical data (e.g., atmospheric, ionospheric, geomagnetic, gravity, etc.) through the establishment of a series of virtual geophysical observatories now being `'deployed'' in cyberspace. The eGY concept is modern, global, and timely; it is attractive, pragmatic, and affordable. The eGY is based on the existing and continually developing computing/networking technologies (e.g., XML, Semantic Web

  5. Subacute Toxicity Study of 40 kGy Irradiated Ready-to-Eat Bulgogi

    International Nuclear Information System (INIS)

    Park, J.G.; Kim, J.H.; Lee, J.W.; Byun, M.W.; Jeon, Y.E.; Kang, I.J.; Hwang, H.J.

    2011-01-01

    The wholesomeness of 40 kGy irradiated ready-to-eat (RTE) bulgogi was evaluated by subacute toxicity studies (body weight, food consumption, organ weight, hematology, serum biochemistry, and histopathological examination) with groups of 40 male and female ICR mice fed the agent at dietary levels of 5% for 90 days. There were no treatment-related adverse effects with regard to body weight, food consumption, organ weight, hematology, serum biochemistry, and histopathology. The no-observed-adverse-effect-level (NOAEL) was also determined to be greater than dietary level of at least 5% (3900 mg/kg body weight/day for males, 3500 mg/kg body weight/day for females) for samples under the present experimental conditions. These results suggest that, under these experimental conditions, RTE bulgogi irradiated at 40 kGy did not show any toxic effects

  6. Results of Zea mays seeds β- irradiation in 0 - 5 Gy range

    International Nuclear Information System (INIS)

    Chicea, Dan; Racuciu, Mihaela

    2008-01-01

    In this study young plants, obtained from the control and beta irradiated seeds, were studied in laboratory experiments. Zea mays seeds with uniform genophond were irradiated with 90 Sr source in the 0 - 5 Gy range. Increased germination percentage was observed under the influence of different radiation doses. We found that small doses of β- radiation have a stimulating effect on the growth of the plantlets, the maximum simulation (among the doses we used) being induced by 0.615 Gy and is statistically significant. We investigated the chlorophyll a to b ratio and the average length variations with the irradiation dose and present the results. Key words: b- radiation, Zea mays, germination rate, plants growth, photoassimilatory pigments,

  7. Histochemical study of reaction of the nucleus supraopticus of rat brain to irradiation with 500 Gy

    International Nuclear Information System (INIS)

    Dosoudilova, M.; Kamarad, V.

    1987-01-01

    The activities were described of some enzymes in nucleus supraopticus of the rat brain at an early interval (5 min) after gamma irradiation with 500 Gy, at a dose rate of 6.9 Gy per minute. The study was performed using cryostat sections. The activities of the following enzymes were shown: alkaline phosphatase, acid phosphatase, ATP-splitting enzyme, thiaminepyrophosphatase, butyrylcholinesterase, acetylcholinesterase, glycero-3-phosphate-dehydrogenase, succinate dehydrogenase, acid nonspecific esterase, and beta glucuronidase. After irradiation, increased activities of acid phosphatase, thiaminepyrophosphatase, and acetylcholinesterase was observed in perikarya of magnocelullar neurons of the nucleus, whereas the activities of other enzymes were weak when compared to controls. A significant decrease in the activity of acidic nonspecific esterase was found. In contrast to the controls, blood capillaries showed increased activities of ATP-splitting enzyme, butyrylcholinesterase, thiaminepyrophosphatase. The activities of alkaline phosphatase and acid phosphatase were not changed. No activity of other enzymes was observed in that site. (author). 13 refs

  8. Pathological study on treated and untreated dogs dead after γ-irradiation with 6 Gy

    International Nuclear Information System (INIS)

    Wang Dewen; Guan Mingchen; Liu Xuetong

    1986-01-01

    Forty dogs γ-irradiated with 6 Gy were divided into three groups: control (8 cases), treated with antibiotics alone (8 cases) and with combined measures (24 cases). The death of dogs in these groups occurred between 8th-12th, 11th-14th and 12th-169th days after irradiation respectively. In the third group, regeneration of hematopoietic cells in sternal bone marrow was first observed in dog dead on 17.5th day after irradiation, and regeneration of lymphoid tissues in spleen on 14th day. The degree of recovery in both of these organs was worse than in dogs irradiated with 3.25 Gy. The complications were varied; for instance, in addition to infection and hemorrhage, there were intussusception, gastric dilation, necrosis and hemorrhage of pancrease, jaundice, cerebral edema, hemorrhage and hernia, cachexia during recovery and so on. The causes of death in these experimental animals were also varied

  9. Pathological study on treated and untreated dogs dead after. gamma. -irradiation with 6 Gy

    Energy Technology Data Exchange (ETDEWEB)

    Dewen, Wang; Mingchen, Guan; Xuetong, Liu

    1986-10-01

    Forty dogs ..gamma..-irradiated with 6 Gy were divided into three groups: control (8 cases), treated with antibiotics alone (8 cases) and with combined measures (24 cases). The death of dogs in these groups occurred between 8th-12th, 11th-14th and 12th-169th days after irradiation respectively. In the third group, regeneration of hematopoietic cells in sternal bone marrow was first observed in dog dead on 17.5th day after irradiation, and regeneration of lymphoid tissues in spleen on 14th day. The degree of recovery in both of these organs was worse than in dogs irradiated with 3.25 Gy. The complications were varied; for instance, in addition to infection and hemorrhage, there were intussusception, gastric dilation, necrosis and hemorrhage of pancrease, jaundice, cerebral edema, hemorrhage and hernia, cachexia during recovery and so on. The causes of death in these experimental animals were also varied.

  10. Transformation of soybean Gy3 gene into Artemisaarenaria mediated by corona discharge

    International Nuclear Information System (INIS)

    Chao, Lu-meng; Na, Ri; Xue, Dan; Xu, Yongze; Liu, Teng

    2013-01-01

    In order to improve the protein content of desert plant, a method of genetic transformation mediated by corona discharge was established. Artemisia seeds were processed in corona electric field for 120 min at 12 kV, and then soaked in 0.1 SSC media that contained Soybean Gy3 gene DNA to incubate for 12 h at 26 °C. Finally the seeds were inoculated on the differentiation medium. Polymerase Chain Reaction (PCR) and Reverse Transcription Polymerase Chain Reaction (RT-PCR) detection showed that the Soybean Gy3 gene had been successfully introduced into genomic DNA of the regenerated plants of Artemisaarenaria. The study provided a new way for corona discharge in plant genetic modification.

  11. Minerals sampling: sensibility analysis and correction factors for Pierre Gy's equation

    International Nuclear Information System (INIS)

    Vallebuona, G.; Niedbalski, F.

    2005-01-01

    Pierre Gy's equation is widely used in ore sampling. This equation is based in four parameters: shape factor, size distribution factor, mineralogical factor and liberation factor. The usual practice is to consider fixed values for the shape and size distribution factors. This practice does not represent well several important ores. The mineralogical factor considers only one specie of interest and the gangue, leaving out other cases such as polymetallic ores where there are more than one species of interest. A sensibility analysis to the Gy's equation factors was done and a procedure to determine specific values for them was developed and presented in this work. mean ore characteristics, associated with an insecure use of the actual procedure, were determined. finally, for a case study, the effects of using each alternative were evaluated. (Author) 4 refs

  12. Local Control With 21-Gy Radiation Therapy for High-Risk Neuroblastoma

    International Nuclear Information System (INIS)

    Casey, Dana L.; Kushner, Brian H.; Cheung, Nai-Kong V.; Modak, Shakeel; LaQuaglia, Michael P.; Wolden, Suzanne L.

    2016-01-01

    Purpose: To evaluate local control after 21-Gy radiation therapy (RT) to the primary site in patients with high-risk neuroblastoma. Methods and Materials: After receiving dose-intensive chemotherapy and gross total resection (GTR), 246 patients (aged 1.2-17.9 years, median 4.0 years) with high-risk neuroblastoma underwent RT to the primary site at Memorial Sloan Kettering from 2000 to 2014. Radiation therapy consisted of 21 Gy in twice-daily fractions of 1.5 Gy each. Local failure (LF) was correlated with biologic prognostic factors and clinical findings at the time of diagnosis and start of RT. Results: Median follow-up of surviving patients was 6.4 years. Cumulative incidence of LF was 7.1% at 2 years after RT and 9.8% at 5 years after RT. The isolated LF rate was 3.0%. Eighty-six percent of all local failures were within the RT field. Local control was worse in patients who required more than 1 surgical resection to achieve GTR (22.4% vs 8.3%, P=.01). There was also a trend toward inferior local control with MYCN-amplified tumors or serum lactate dehydrogenase ≥1500 U/L (P=.09 and P=.06, respectively). Conclusion: After intensive chemotherapy and maximal surgical debulking, hyperfractionated RT with 21 Gy in high-risk neuroblastoma results in excellent local control. Given the young patient age, concern for late effects, and local control >90%, dose reduction may be appropriate for patients without MYCN amplification who achieve GTR.

  13. ESR/Alanine {gamma}-dosimetry in the 10-30 Gy range

    Energy Technology Data Exchange (ETDEWEB)

    Fainstein, C. E-mail: cfainstein@cab.cnea.gov.ar; Winkler, E.; Saravi, M

    2000-05-15

    We report Alanine Dosimeter preparation, procedures for using the ESR/Dosimetry method, and the resulting calibration curve for {gamma}-irradiation in the range from 10-30 Gy. We use calibration curve to measure the irradiation dose in {gamma}-irradiation of human blood, as required in Blood Transfusion Therapy. The ESR/Alanine results are compared against those obtained using the thermoluminescent dosimetry (TLD) method.

  14. Comparing morbidity and cancer control after 3D-conformal (70/74 Gy) and intensity modulated radiotherapy (78/82 Gy) for prostate cancer

    International Nuclear Information System (INIS)

    Dolezel, Martin; Odrazka, Karel; Zouhar, Milan; Jansa, Jan; Paluska, Petr; Vaculikova, Miloslava; Sefrova, Jana; Kohlova, Tereza; Vanasek, Jaroslav; Kovarik, Josef

    2015-01-01

    The purpose of this work was to compare toxicity and cancer control between patients with prostate cancer treated using three-dimensional conformal radiotherapy (3D-CRT) and those treated using intensity-modulated radiation therapy (IMRT). A total of 553 patients with prostate cancer were treated with 3D-CRT 70-74 Gy (3D-CRT 70, 3D-CRT 74) or IMRT 78-82 Gy (IMRT 78, IMRT/SIB 82). Late toxicity was scored according to FC-RTOG/LENT criteria. Biochemical failure was defined using the Phoenix and ASTRO definitions. The 5-year risk of grade 2-4 genitourinary toxicity was 26.3 % (3D-CRT 70), 27.2 % (3D-CRT 74), 17.3 % (IMRT 78), and 25.1 % (IMRT/SIB 82) without statistical differences. The 5-year risk of grade 2-4 gastrointestinal toxicity was 19.4 % (3D-CRT 70), 42.1 % (3D-CRT 74), 20.5 % (IMRT 78), and 26.6 % (IMRT/SIB 82). The differences between 3D-CRT 74 and 3D-CRT 70 and between 3D-CRT 74 and IMRT 78 were statistically significant (log rank p = 0.03). The 5-year Phoenix PSA relapse-free survival (PSA-RFS) in low-risk, intermediate-risk, and high-risk patients treated using 3D-CRT were 89.4, 65.5, and 57.8 %, respectively. Patients treated with IMRT achieved the following results: 90.9, 89.4, and 83.9 %. Clinical relapse-free survival (C-RFS) in patients treated using 3D-CRT vs. IMRT for the aforementioned groups were 94.7 vs. 100 %, 86.8 vs. 98.6 %, and 84.4 vs. 94.5 %. Disease-free survival (DFS) for patients treated using 3D-CRT were 83.1, 70.9, and 71.5 %. The IMRT group reached 95.8, 89.1, and 87.6 %. The PSA-RFS for intermediate- and high-risk patients were statistically significant, while C-RFS and DFS were marginally better. Dose escalation with IMRT was associated with improved cancer control in intermediate- and high-risk patients in comparison with 3D-CRT, without compromising toxicity. (orig.) [de

  15. The Ringhoffer family firm´s stratégy between continuity and change

    Czech Academy of Sciences Publication Activity Database

    Hlavačka, Milan

    2015-01-01

    Roč. 30, č. 2 (2015), s. 201-206 ISSN 0231-7540 R&D Projects: GA ČR(CZ) GA14-19640S Institutional support: RVO:67985963 Keywords : the Ringhoffer family * firm stratégy * economic history * transformation into joint-venture company Subject RIV: AB - History OBOR OECD: History (history of science and technology to be 6.3, history of specific sciences to be under the respective headings)

  16. Local Control With 21-Gy Radiation Therapy for High-Risk Neuroblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Casey, Dana L. [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Kushner, Brian H.; Cheung, Nai-Kong V.; Modak, Shakeel [Department of Pediatrics, Memorial Sloan Kettering Cancer Center, New York, New York (United States); LaQuaglia, Michael P. [Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, New York (United States); Wolden, Suzanne L., E-mail: woldens@mskcc.org [Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York (United States)

    2016-10-01

    Purpose: To evaluate local control after 21-Gy radiation therapy (RT) to the primary site in patients with high-risk neuroblastoma. Methods and Materials: After receiving dose-intensive chemotherapy and gross total resection (GTR), 246 patients (aged 1.2-17.9 years, median 4.0 years) with high-risk neuroblastoma underwent RT to the primary site at Memorial Sloan Kettering from 2000 to 2014. Radiation therapy consisted of 21 Gy in twice-daily fractions of 1.5 Gy each. Local failure (LF) was correlated with biologic prognostic factors and clinical findings at the time of diagnosis and start of RT. Results: Median follow-up of surviving patients was 6.4 years. Cumulative incidence of LF was 7.1% at 2 years after RT and 9.8% at 5 years after RT. The isolated LF rate was 3.0%. Eighty-six percent of all local failures were within the RT field. Local control was worse in patients who required more than 1 surgical resection to achieve GTR (22.4% vs 8.3%, P=.01). There was also a trend toward inferior local control with MYCN-amplified tumors or serum lactate dehydrogenase ≥1500 U/L (P=.09 and P=.06, respectively). Conclusion: After intensive chemotherapy and maximal surgical debulking, hyperfractionated RT with 21 Gy in high-risk neuroblastoma results in excellent local control. Given the young patient age, concern for late effects, and local control >90%, dose reduction may be appropriate for patients without MYCN amplification who achieve GTR.

  17. Antecedents of Gray Divorce: A Life Course Perspective.

    Science.gov (United States)

    Lin, I-Fen; Brown, Susan L; Wright, Matthew R; Hammersmith, Anna M

    2016-12-16

    Increasingly, older adults are experiencing divorce, yet little is known about the risk factors associated with divorce after age 50 (termed "gray divorce"). Guided by a life course perspective, our study examined whether key later life turning points are related to gray divorce. We used data from the 1998-2012 Health and Retirement Study to conduct a prospective, couple-level discrete-time event history analysis of the antecedents of gray divorce. Our models incorporated key turning points (empty nest, retirement, and poor health) as well as demographic characteristics and economic resources. Contrary to our expectations, the onset of an empty nest, the wife's or husband's retirement, and the wife's or husband's chronic conditions were unrelated to the likelihood of gray divorce. Rather, factors traditionally associated with divorce among younger adults were also salient for older adults. Marital duration, marital quality, home ownership, and wealth were negatively related to the risk of gray divorce. Gray divorce is especially likely to occur among couples who are socially and economically disadvantaged, raising new questions about the consequences of gray divorce for individual health and well-being. © The Author 2016. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. Increased expressions of MMP-2 and MMP-9 in lung following 12 Gy local irradiation

    International Nuclear Information System (INIS)

    Yang Kunyu; Liu Li; Zhang Tao; Wu Gang; Hu Yu; Ruebe, C.; Ruebe, C.

    2006-01-01

    Objective: To measure expressions of metalloproteinases and tissue inhibitors of metalloproteinases in the lung following thoracic irradiation of 12 Gy, and explore its possible role in the development of radiation-induced lung damage. Methods: C57BL/6J mice at age of 8 weeks were thoracically irradiated with 12 Gy X-rays (10 MV, 2.4 Gy/min, single exposure), and the control mice were sham-irradiated. The mice were sacrificed at 4 or 8 weeks after thoracic irradiation by decapitation. Lung tissues samples were collected. Expressions of MMP-2, MMP-9, MMP-3, MMP-13, TIMP-1, TIMP-2, and TIMP-3 in lung samples were measured. Results: There was no significant difference in expressions of MMP-3, MMP-13, TIMP-1 TIMP-2, and TIMP-3 in the lung between the two groups at 4 and 8 weeks after thoracic irradiation (or sham-irradiation). However, the expressions of MMP-2 were enhanced by 1.7 and 1.9 folds, and MMP-9 by 2.7 and 2.6 folds at 4 and 8 weeks after thoracic irradiation, respectively. Conclusion: Enhanced expressions of MMP-2 and MMP-9 in the lung were involved in the development of acute lung injury after thoracic irradiation, leading to a disruption of the structure and fibrosis. (authors)

  19. Sterilization of allograft bone: is 25 kGy the gold standard for gamma irradiation?

    Science.gov (United States)

    Nguyen, Huynh; Morgan, David A F; Forwood, Mark R

    2007-01-01

    For several decades, a dose of 25 kGy of gamma irradiation has been recommended for terminal sterilization of medical products, including bone allografts. Practically, the application of a given gamma dose varies from tissue bank to tissue bank. While many banks use 25 kGy, some have adopted a higher dose, while some choose lower doses, and others do not use irradiation for terminal sterilization. A revolution in quality control in the tissue banking industry has occurred in line with development of quality assurance standards. These have resulted in significant reductions in the risk of contamination by microorganisms of final graft products. In light of these developments, there is sufficient rationale to re-establish a new standard dose, sufficient enough to sterilize allograft bone, while minimizing the adverse effects of gamma radiation on tissue properties. Using valid modifications, several authors have applied ISO standards to establish a radiation dose for bone allografts that is specific to systems employed in bone banking. These standards, and their verification, suggest that the actual dose could be significantly reduced from 25 kGy, while maintaining a valid sterility assurance level (SAL) of 10(-6). The current paper reviews the methods that have been used to develop radiation doses for terminal sterilization of medical products, and the current trend for selection of a specific dose for tissue banks.

  20. γ-Radiation (0-150 kGy) Effects on HDPE/LDPE Blends

    International Nuclear Information System (INIS)

    Albano, C.

    2006-01-01

    In the present work, irradiation with 60 C o source was employed to study the effect of γ-rays on some physical properties of HDPE/LDPE blends (0/100, 10/90, 25/75, 50/50, 75/25, 100/0), using various doses: 0, 50, 150 kGy. The blends were prepared by extrusion and plates were compression molded employing fast and slow cooling methods from the melt. Density, degree of crystallinity and mechanical properties were dependant on the cooling rate used and blend composition. Better properties were found for HDPE-rich blends. Mechanical properties showed no significant variations in tensile modulus and yield stress. Instead, a decrease in elongation at break, due to molecular crosslinking or branching reaction effects, with the raise of radiation dose was obtained. Density measurements and differential scanning calorimetry results failed to exhibit significant changes with radiation dose. Some qualitative aspects included changes in endotherms shape. These were attributed to the variation of in crystallite sizes, probably due to structural changes originated by crosslinking and chain scission reactions occurring as a result of γ-rays exposure. On the other hand, there was an abrupt reduction of the melt flow index (MFI) from the range of 16-9 dg/min for 0 kGy to non-fluidity for an exposure of 150 kGy; this behavior is another sign of high crosslinking, impairing the viscous fluidity of the blends

  1. Potential ungulate prey for Gray Wolves

    Science.gov (United States)

    Singer, Francis J.; Mack, John A.

    1993-01-01

    Data were gathered for six ungulate species that reside in or near Yellowstone National Park. If gray wolves (Canis lupus) are reintroduced into the Yellowstone area, their avoidance of human activities or their management by human may determine their range. Therefore, the area of wolf occupation cannot be predicted now. We restricted our analysis to Yellowstone National Park and to the adjacent national forest wilderness areas. We included mostly ungulate herds that summer inside or adjacent to the park and that would probably be affected by wolves. Our wolf study area includes Yellowstone National Park and adjacent wilderness areas most likely to be occupied by wolves. We reviewed publications, park records, survey reports, and state fish and game surveys and reports for statistics on ungulate populations. These data [provide an overview of ungulate populations and harvests. Each ungulate herd is described in detail. We restricted our analysis to 1980-89, because population surveys were more complete during that period and because population estimates of most ungulate populations had increased by the 1980's. We feel the higher estimates of the 1980's reflect more up-to-date techniques and are most representative of the situation into which the wolves would be reintroduced.

  2. Black and gray Helmholtz-Kerr soliton refraction

    International Nuclear Information System (INIS)

    Sanchez-Curto, Julio; Chamorro-Posada, Pedro; McDonald, Graham S.

    2011-01-01

    Refraction of black and gray solitons at boundaries separating different defocusing Kerr media is analyzed within a Helmholtz framework. A universal nonlinear Snell's law is derived that describes gray soliton refraction, in addition to capturing the behavior of bright and black Kerr solitons at interfaces. Key regimes, defined by beam and interface characteristics, are identified, and predictions are verified by full numerical simulations. The existence of a unique total nonrefraction angle for gray solitons is reported; both internal and external refraction at a single interface is shown possible (dependent only on incidence angle). This, in turn, leads to the proposal of positive or negative lensing operations on soliton arrays at planar boundaries.

  3. Conformal radiotherapy to 76 Gy in localized prostate cancer. Therapeutic modalities and preliminary results

    International Nuclear Information System (INIS)

    Pontvert, D.; Mammar, H.; Flam, T.; Debre, B.; Thiounn, N.; Gaboriaud, G.; Jourdan-Da Silvae, N.; Beuzeboc, P.

    2008-01-01

    Purpose: to describe therapeutic modalities for localized prostate cancer treated by conformal radiation to 76 Gy with or without androgen ablation. To evaluate the preliminary results in terms of survival, biological control and toxicity. Patients and method: between January 1998 and June 2001, 321 patients with localized prostate cancer were irradiated at Institut Curie. Tumors were stratified into the three Memorial Sloan-Kettering Cancer Center prognostic groups (1998) for analysis: favorable risk group (F.G.) 23%, intermediate risk group (I.G.) 36.5%, unfavorable risk group (U.G.) 40.5%. Androgen deprivation, mainly neo-adjuvant, less or equal to one year was prescribed to 93.8% of patients (72.6% less or equal to six months). Planning target volume prescription doses were: prostate: 76 Gy, seminal vesicles: 56 to 76 Gy, and pelvic lymph nodes: 44 Gy to 16.8% of patients. Results: the five-year actuarial overall survival was 94% (95% I.C.: 90-97%). The median post-therapeutic follow-up was 36 months (nine to 60 months). The 48-month actuarial rates of biochemical control for the three prognostic groups were statistically different according to both the American Society for Therapeutic Radiology and Oncology consensus (A.S.T.R.O. 1997) and the Fox Chase Cancer Center definitions of biochemical failure (F.C.C.C. 2000) with respectively 87 and 94% for F.G., 78 and 84% for I.G., 54 and 58% for U.G. (P < 10-6 and P < 10-8). At time of our analysis, late post-treatment rectal and bladder bleedings were 17,4 and 13,6%, respectively. According to a 1-4 scale adapted from M.D. Anderson Cancer Center criteria: rectal bleedings were grade 1 (9.6%), grade 2 (6.2%) and grade 3 (1.6%). Bladder bleedings were grade 2 (13%) and grade 3 (0.6%). Analysis of rectal bleeding risk factors showed significant correlations with pelvic lymph nodes irradiation for grade 2 and 3, (P = 0.02), and for all grades, a correlation with smaller rectal wall volumes (P = 0.03), and greater

  4. Differences in quantitative assessment of myocardial scar and gray zone by LGE-CMR imaging using established gray zone protocols.

    Science.gov (United States)

    Mesubi, Olurotimi; Ego-Osuala, Kelechi; Jeudy, Jean; Purtilo, James; Synowski, Stephen; Abutaleb, Ameer; Niekoop, Michelle; Abdulghani, Mohammed; Asoglu, Ramazan; See, Vincent; Saliaris, Anastasios; Shorofsky, Stephen; Dickfeld, Timm

    2015-02-01

    Late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) imaging is the gold standard for myocardial scar evaluation. Heterogeneous areas of scar ('gray zone'), may serve as arrhythmogenic substrate. Various gray zone protocols have been correlated to clinical outcomes and ventricular tachycardia channels. This study assessed the quantitative differences in gray zone and scar core sizes as defined by previously validated signal intensity (SI) threshold algorithms. High quality LGE-CMR images performed in 41 cardiomyopathy patients [ischemic (33) or non-ischemic (8)] were analyzed using previously validated SI threshold methods [Full Width at Half Maximum (FWHM), n-standard deviation (NSD) and modified-FWHM]. Myocardial scar was defined as scar core and gray zone using SI thresholds based on these methods. Scar core, gray zone and total scar sizes were then computed and compared among these models. The median gray zone mass was 2-3 times larger with FWHM (15 g, IQR: 8-26 g) compared to NSD or modified-FWHM (5 g, IQR: 3-9 g; and 8 g. IQR: 6-12 g respectively, p zone extent (percentage of total scar that was gray zone) also varied significantly among the three methods, 51 % (IQR: 42-61 %), 17 % (IQR: 11-21 %) versus 38 % (IQR: 33-43 %) for FWHM, NSD and modified-FWHM respectively (p zone and scar core. Infarct core and total myocardial scar mass also differ using these methods. Further evaluation of the most accurate quantification method is needed.

  5. Muusikamaailm : "Represseeritud muusika" Moskvas. György Kurtagi festival Londonis. Junge Deutshe Philarmonie kevad. Herbert Wernicke lahkunud / Priit Kuusk

    Index Scriptorium Estoniae

    Kuusk, Priit, 1938-

    2002-01-01

    Moskvas toimuvast festivalist "Represseeritud muusika". Londonis toimuvast György Kurtagi festivalist. Saksa orkestri Junge Deutshe Philarmonie kevadesinemistest. Suri saksa ooperilavastaja Herbert Wernicke

  6. Gray Matter Is Targeted in First-Attack Multiple Sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Schutzer, Steven E.; Angel, Thomas E.; Liu, Tao; Schepmoes, Athena A.; Xie, Fang; Bergquist, Jonas P.; Vecsei, Lazlo' ; Zadori, Denes; Camp, David G.; Holland, Bart K.; Smith, Richard D.; Coyle, Patricia K.

    2013-09-10

    The cause of multiple sclerosis (MS), its driving pathogenesis at the earliest stages, and what factors allow the first clinical attack to manifest remain unknown. Some imaging studies suggest gray rather than white matter may be involved early, and some postulate this may be predictive of developing MS. Other imaging studies are in conflict. To determine if there was objective molecular evidence of gray matter involvement in early MS we used high-resolution mass spectrometry to identify proteins in the cerebrospinal fluid (CSF) of first-attack MS patients (two independent groups) compared to established relapsing remitting (RR) MS and controls. We found that the CSF proteins in first-attack patients were differentially enriched for gray matter components (axon, neuron, synapse). Myelin components did not distinguish these groups. The results support that gray matter dysfunction is involved early in MS, and also may be integral for the initial clinical presentation.

  7. Comparison of Cox and Gray's survival models in severe sepsis

    DEFF Research Database (Denmark)

    Kasal, Jan; Andersen, Zorana Jovanovic; Clermont, Gilles

    2004-01-01

    Although survival is traditionally modeled using Cox proportional hazards modeling, this approach may be inappropriate in sepsis, in which the proportional hazards assumption does not hold. Newer, more flexible models, such as Gray's model, may be more appropriate....

  8. Severe maxillary osteomyelitis in a Gray Wolf (Canis lupus)

    Science.gov (United States)

    Barber-Meyer, Shannon

    2012-01-01

    Dental injuries to or abnormalities in functionally important teeth and associated bones in predators may significantly reduce the ability to kill and consume prey (Lazar et al. 2009). This impairment is likely exacerbated in coursing predators, such as Gray Wolves, that bite and hold onto fleeing and kicking prey with their teeth. Damage to carnassials (upper fourth premolar, P4, and lower first molar, M1) and associated bones in Gray Wolves may especially inhibit the consumption of prey because these teeth slice meat and crush bone. Here I report maxillary osteomyelitis involving the carnassials in a wild Gray Wolf from northeastern Minnesota of such severity that I hypothesize it ultimately caused the Gray Wolf to starve to death.

  9. Low-Dose Radiation Therapy (2 Gy × 2) in the Treatment of Orbital Lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Fasola, Carolina E. [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Jones, Jennifer C. [Vaccine Branch, Center for Cancer Research, National Cancer Institute, Bethesda, Maryland (United States); Huang, Derek D. [Department of Internal Medicine, University of California-Los Angeles Olive View, Sylmar, California (United States); Le, Quynh-Thu; Hoppe, Richard T. [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Donaldson, Sarah S., E-mail: sarah2@stanford.edu [Department of Radiation Oncology, Stanford University, Stanford, California (United States)

    2013-08-01

    Purpose: Low-dose radiation has become increasingly used in the management of indolent non-Hodgkin lymphoma (NHL), but has not been studied specifically for cases of ocular adnexal involvement. The objective of this study is to investigate the effectiveness of low-dose radiation in the treatment of NHL of the ocular adnexa. Methods and Materials: We reviewed the records of 20 NHL patients with 27 sites of ocular adnexal involvement treated with low-dose radiation consisting of 2 successive fractions of 2 Gy at our institution between 2005 and 2011. The primary endpoint of this study is freedom from local relapse (FFLR). Results: At a median follow-up time of 26 months (range 7-92), the overall response rate for the 27 treated sites was 96%, with a complete response (CR) rate of 85% (n=23) and a partial response rate of 11% (n=3). Among all treated sites with CR, the 2-year FFLR was 100%, with no in-treatment field relapses. The 2-year freedom from regional relapse rate was 96% with 1 case of relapse within the ipsilateral orbit (outside of the treatment field). This patient underwent additional treatment with low-dose radiation of 4 Gy to the area of relapse achieving a CR and no evidence of disease at an additional 42 months of follow-up. Orbital radiation was well tolerated with only mild acute side effects (dry eye, conjunctivitis, transient periorbital edema) in 30% of treated sites without any reports of long-term toxicity. Conclusions: Low-dose radiation with 2 Gy × 2 is effective and well tolerated in the treatment of indolent NHL of the ocular adnexa with high response rates and durable local control with the option of reirradiation in the case of locoregional relapse.

  10. Low-Dose Radiation Therapy (2 Gy × 2) in the Treatment of Orbital Lymphoma

    International Nuclear Information System (INIS)

    Fasola, Carolina E.; Jones, Jennifer C.; Huang, Derek D.; Le, Quynh-Thu; Hoppe, Richard T.; Donaldson, Sarah S.

    2013-01-01

    Purpose: Low-dose radiation has become increasingly used in the management of indolent non-Hodgkin lymphoma (NHL), but has not been studied specifically for cases of ocular adnexal involvement. The objective of this study is to investigate the effectiveness of low-dose radiation in the treatment of NHL of the ocular adnexa. Methods and Materials: We reviewed the records of 20 NHL patients with 27 sites of ocular adnexal involvement treated with low-dose radiation consisting of 2 successive fractions of 2 Gy at our institution between 2005 and 2011. The primary endpoint of this study is freedom from local relapse (FFLR). Results: At a median follow-up time of 26 months (range 7-92), the overall response rate for the 27 treated sites was 96%, with a complete response (CR) rate of 85% (n=23) and a partial response rate of 11% (n=3). Among all treated sites with CR, the 2-year FFLR was 100%, with no in-treatment field relapses. The 2-year freedom from regional relapse rate was 96% with 1 case of relapse within the ipsilateral orbit (outside of the treatment field). This patient underwent additional treatment with low-dose radiation of 4 Gy to the area of relapse achieving a CR and no evidence of disease at an additional 42 months of follow-up. Orbital radiation was well tolerated with only mild acute side effects (dry eye, conjunctivitis, transient periorbital edema) in 30% of treated sites without any reports of long-term toxicity. Conclusions: Low-dose radiation with 2 Gy × 2 is effective and well tolerated in the treatment of indolent NHL of the ocular adnexa with high response rates and durable local control with the option of reirradiation in the case of locoregional relapse

  11. Effects of 5-Gy irradiation on fertility and mating behaviour of Nezara viridula (Heteroptera: Pentatomidae)

    International Nuclear Information System (INIS)

    Zunic, A.; Cokl, A.; Sersa, G.

    2002-01-01

    Background. The polyphagous and cosmopolitan species Nezara viridula is one of the most important insect pests. The sterile insect technique (SIT) is a pest control strategy that involves sterilising males by exposing them to ionising radiation. Sterile males, released into wild population, mate with females, but eggs are not fertilised and the population gradually declines. Exposing insects to radiation during their growth stage might require lower sterilising dose. The aim of our study was to test whether 5-Gy irradiation of 5 th instar nymphs significantly affects: (1) moulting and further development of the irradiated nymphs, (2) the male's and female's reproductive system and (3) the mating competitiveness of treated males, with special focus on vibrational communication. Methods: The 5 th instar nymphs were irradiated with 5 Gy using X-ray generator and monitored daily. Results: The observed effects of irradiation were: prolonged moulting, increased mortality during development and during the first day of adult life, decreased males to females ratio, decreased fecundity, egg production, proportion of fertile eggs and progeny survival. The reaction of a male to stimulation with the model female calling song was tested. The irradiated and non-irradiated males responded to stimulation with emission of the courtship song (MCrS). Temporal parameters of MCrS emitted by non-irradiated males differed when compared with those of irradiated ones. Conclusions: The 5-Gy irradiation of 5 th instar nymphs did not affect mating behaviour. However since the irradiation during growth stage decreased the fertility and fecundity of emerged adults, this technique, in combination with certain other suppression techniques, could be a successful control strategy for management of Nezara viridula. On the other hand observed effects on moulting and further development of the irradiated nymphs could decrease the efficiency and application of this strategy. (author)

  12. Clinical results of definitive-dose (50 Gy/25 fractions) preoperative chemoradiotherapy for unresectable esophageal cancer

    International Nuclear Information System (INIS)

    Ishikawa, Kazuki; Nakamatsu, Kiyoshi; Shiraishi, Osamu; Yasuda, Takushi; Nishimura, Yasumasa

    2015-01-01

    The clinical results of definitive-dose preoperative chemoradiotherapy (CRT) of 50 Gy/25 fractions/5 weeks for unresectable esophageal cancer were analyzed. Inclusion criteria were unresectable esophageal squamous cell carcinoma with T4b or mediastinal lymph nodes invading to the trachea or aorta. Radiation therapy of 50 Gy/25 fractions/5 weeks was combined concurrently with two courses of FP therapy (CDDP 70 mg/m 2 + 5-FU 700 mg/m 2 /d x 5 days: day 1-5, day 29-33). Tumor response was evaluated 4 weeks after completion of RT. Subtotal esophagectomy was planned 6-8 weeks after RT. Thirty patients (26 male and 4 female) aged from 50-78 years (median 66) were enrolled between 2008 and 2011. The clinical stages according to the 7th edition of UICC were stages II/III/IV, 1/23/6; T1/2/3/4, 1/1/4/24; and N0/1/2/3, 3/25/1/1. All 30 patients completed RT of 50 Gy/ 25 fractions. Initial tumor responses were 21 patients with resectable disease, 7 with unresectable disease, and 2 with progressive disease. Subtotal esophagectomy was performed in 18 (60%) of the 30 patients. Pathological complete response was obtained in five (28%) patients. There were two patients with hospitalization death after surgery (11%). Six of the 7 patients who still had unresectable disease were treated with 1-3 courses of docetaxel, CDDP and 5-FU. Three patients treated without surgery showed long-term survival. The 3-year locoregional control rate and the 3-year overall survival rate for the 30 patients were 70 and 49%, respectively. Definitive-dose preoperative CRT was feasible, and is a promising treatment strategy for unresectable esophageal cancer. (author)

  13. Economic Development and Economic Governance Through the Example of the City of Győr

    Directory of Open Access Journals (Sweden)

    Dávid Fekete

    2018-04-01

    Full Text Available Since the 1990s the metropolitan region and its governance has got into the focus of regional science again. Nowadays a newer wave of metropolitan governance is authoritative, which has exceeded the former administrative-territorial planning aspects, and has appeared on the scene as the mechanism of economic development policy. Examining the development stages of regional policy it is well-known that the classical (modern approach was superseded by the postmodern one. While the national methods applied in the classical period were characterized by strictness, central regulation, indirect regulation of the market (Fordist approach, in the postmodern period flexibility, decentralization and direct regulation have come to the fore (Post-Fordism. In the postmodern period the state level also takes its role in the financing of innovation and research&development, and the notions of networking and competitiveness are coming more and more to the fore. In this article I analyze these processes through the case study of Győr. After the theoretical introduction I examine the tools of economic development and economic governance in the Győr metropolitan region. Activities observed in Győr can strengthen the view-point that the processes of economic development and economic governance have nowadays been going on in parallel with each other. Moreover, the coordinating activities of local authorities can be observed in the work of organizations that support economic governance. In the course of the research it was also confirmed that built infrastructure can serve as a fundamental condition for the cooperation of network-systems that operate the governance system of a municipality.

  14. A randomized phase II trial of concurrent chemoradiation with two doses of radiotherapy, 60Gy and 66Gy, concomitant with a fixed dose of oral vinorelbine in locally advanced NSCLC

    DEFF Research Database (Denmark)

    Hansen, Olfred; Knap, Marianne M; Khalil, Azza

    2017-01-01

    was local progression free interval. A scheduled FDG-PET-CT-scan was performed 9months after randomization. The study was registered at ClinicalTrials.gov (NCT 00887783). RESULTS: Both arms were well tolerated. The local progression free interval at 9months was 54% in the 60Gy arm and 59% in the 66Gy arm...

  15. Gray Matter Concentration Abnormality in Brains of Narcolepsy Patients

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Eun Yeon; Tae, Woo Suk; Kim, Sung Tae; Hong, Seung Bong [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2009-12-15

    To investigate gray matter concentration changes in the brains of narcoleptic patients. Twenty-nine narcoleptic patient with cataplexy and 29 age and sex-matched normal subjects (mean age, 31 years old) underwent volumetric MRIs. The MRIs were spatially normalized to a standard T1 template and subdivided into gray matter, white matter, and cerebrospinal fluid (CSF). These segmented images were then smoothed using a 12-mm full width at half maximum (FWHM) isotropic Gaussian kernel. An optimized voxel-based morphometry protocol was used to analyze brain tissue concentrations using SPM2 (statistical parametric mapping). A one-way analysis of variance was applied to the concentration analysis of gray matter images. Narcoleptics with cataplexy showed reduced gray matter concentration in bilateral thalami, left gyrus rectus, bilateral frontopolar gyri, bilateral short insular gyri, bilateral superior frontal gyri, and right superior temporal and left inferior temporal gyri compared to normal subjects (uncorrected p < 0.001). Furthermore, small volume correction revealed gray matter concentration reduction in bilateral nuclei accumbens, hypothalami, and thalami (false discovery rate corrected p < 0.05). Gray matter concentration reductions were observed in brain regions related to excessive daytime sleepiness, cognition, attention, and memory in narcoleptics with cataplexy

  16. Gray Matter Concentration Abnormality in Brains of Narcolepsy Patients

    International Nuclear Information System (INIS)

    Joo, Eun Yeon; Tae, Woo Suk; Kim, Sung Tae; Hong, Seung Bong

    2009-01-01

    To investigate gray matter concentration changes in the brains of narcoleptic patients. Twenty-nine narcoleptic patient with cataplexy and 29 age and sex-matched normal subjects (mean age, 31 years old) underwent volumetric MRIs. The MRIs were spatially normalized to a standard T1 template and subdivided into gray matter, white matter, and cerebrospinal fluid (CSF). These segmented images were then smoothed using a 12-mm full width at half maximum (FWHM) isotropic Gaussian kernel. An optimized voxel-based morphometry protocol was used to analyze brain tissue concentrations using SPM2 (statistical parametric mapping). A one-way analysis of variance was applied to the concentration analysis of gray matter images. Narcoleptics with cataplexy showed reduced gray matter concentration in bilateral thalami, left gyrus rectus, bilateral frontopolar gyri, bilateral short insular gyri, bilateral superior frontal gyri, and right superior temporal and left inferior temporal gyri compared to normal subjects (uncorrected p < 0.001). Furthermore, small volume correction revealed gray matter concentration reduction in bilateral nuclei accumbens, hypothalami, and thalami (false discovery rate corrected p < 0.05). Gray matter concentration reductions were observed in brain regions related to excessive daytime sleepiness, cognition, attention, and memory in narcoleptics with cataplexy

  17. Cognitive Implications of Deep Gray Matter Iron in Multiple Sclerosis.

    Science.gov (United States)

    Fujiwara, E; Kmech, J A; Cobzas, D; Sun, H; Seres, P; Blevins, G; Wilman, A H

    2017-05-01

    Deep gray matter iron accumulation is increasingly recognized in association with multiple sclerosis and can be measured in vivo with MR imaging. The cognitive implications of this pathology are not well-understood, especially vis-à-vis deep gray matter atrophy. Our aim was to investigate the relationships between cognition and deep gray matter iron in MS by using 2 MR imaging-based iron-susceptibility measures. Forty patients with multiple sclerosis (relapsing-remitting, n = 16; progressive, n = 24) and 27 healthy controls were imaged at 4.7T by using the transverse relaxation rate and quantitative susceptibility mapping. The transverse relaxation rate and quantitative susceptibility mapping values and volumes (atrophy) of the caudate, putamen, globus pallidus, and thalamus were determined by multiatlas segmentation. Cognition was assessed with the Brief Repeatable Battery of Neuropsychological Tests. Relationships between cognition and deep gray matter iron were examined by hierarchic regressions. Compared with controls, patients showed reduced memory ( P processing speed ( P = .02) and smaller putamen ( P deep gray matter iron accumulation in the current multiple sclerosis cohort. Atrophy and iron accumulation in deep gray matter both have negative but separable relationships to cognition in multiple sclerosis. © 2017 by American Journal of Neuroradiology.

  18. Spinal Cord Gray Matter Atrophy in Amyotrophic Lateral Sclerosis.

    Science.gov (United States)

    Paquin, M-Ê; El Mendili, M M; Gros, C; Dupont, S M; Cohen-Adad, J; Pradat, P-F

    2018-01-01

    There is an emerging need for biomarkers to better categorize clinical phenotypes and predict progression in amyotrophic lateral sclerosis. This study aimed to quantify cervical spinal gray matter atrophy in amyotrophic lateral sclerosis and investigate its association with clinical disability at baseline and after 1 year. Twenty-nine patients with amyotrophic lateral sclerosis and 22 healthy controls were scanned with 3T MR imaging. Standard functional scale was recorded at the time of MR imaging and after 1 year. MR imaging data were processed automatically to measure the spinal cord, gray matter, and white matter cross-sectional areas. A statistical analysis assessed the difference in cross-sectional areas between patients with amyotrophic lateral sclerosis and controls, correlations between spinal cord and gray matter atrophy to clinical disability at baseline and at 1 year, and prediction of clinical disability at 1 year. Gray matter atrophy was more sensitive to discriminate patients with amyotrophic lateral sclerosis from controls ( P = .004) compared with spinal cord atrophy ( P = .02). Gray matter and spinal cord cross-sectional areas showed good correlations with clinical scores at baseline ( R = 0.56 for gray matter and R = 0.55 for spinal cord; P amyotrophic lateral sclerosis. © 2018 by American Journal of Neuroradiology.

  19. Effects of 2.0 Gy of 60Co gamma rays irradiation on rat embryos

    International Nuclear Information System (INIS)

    Lee, Juing-Yi; Satow, Yukio

    1987-01-01

    Pregnant rats of Donryu strain were exposed to a whole-body 60 Co γ ray irradiation of a single dose of 2.0 Gy (Dose rate: 0.5 Gy/min) on day 7, 8, 9, 10 or 11 of gestation (sperm day = day 0). The rats were sacrificed on day 18 and the offspring were examined for external and visceral malformations. Malformed embryos occurred between days 7 and 11 with the highest incidence occurring on day 9. Dose with 2.0 Gy increased the rate of resorption or death (52.1 %), in the survivors, caused congenital malformation in a majority of embryos (86.5 %) on day 8 of gestation. There is an increase in malformation (93.3 %) and growth retardation, but no increase in mortality (42.9 %) on day 9 of gestation. Relatively few anomalies resulted from irradiation on day 7 of gestation. The peak day for cardiovascular anomalies occurred on day 9 (88.3 % of all survival embryos) with high levels also occurring on day 8 (86.5 %). Cardiovascular anomalies consisted of VSD, hypoplasia of the pulmonary trunk, coarctation of the aorta, double aortic arch, right aortic arch, riding aorta, complete transposition of the aorta, persistent atrioventricular canal, vascular ring, aberrant right subclavian artery and others. Similar anomalies, but at a lower incidence, were produced by 60 Co γ ray at dose levels of 2.0 Gy on day 10 or 11 of gestation. Cases of cleft lip and cleft palate or facial cleft were observed seventeen fetuses on day 9 of gestation (31 %). Exencephaly occurred in nine embryos treated on day 9 (16.1 %) and in one embryos treated on day 10. Tail defects appeared with treatment on day 9 with the latter predominating on day 11. The present study show that maximum resorption (52.1 %) was seen with treatment on day 8 whereas the highest rate of malformation (93.3 %) was observed with treatment on day 9. (J.P.N.)

  20. Effects of 2. 0 Gy of /sup 60/Co gamma rays irradiation on rat embryos

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Juing-Yi; Satow, Yukio

    1987-01-01

    Pregnant rats of Donryu strain were exposed to a whole-body /sup 60/Co ..gamma.. ray irradiation of a single dose of 2.0 Gy (Dose rate: 0.5 Gy/min) on day 7, 8, 9, 10 or 11 of gestation (sperm day = day 0). The rats were sacrificed on day 18 and the offspring were examined for external and visceral malformations. Malformed embryos occurred between days 7 and 11 with the highest incidence occurring on day 9. Dose with 2.0 Gy increased the rate of resorption or death (52.1 %), in the survivors, caused congenital malformation in a majority of embryos (86.5 %) on day 8 of gestation. There is an increase in malformation (93.3 %) and growth retardation, but no increase in mortality (42.9 %) on day 9 of gestation. Relatively few anomalies resulted from irradiation on day 7 of gestation. The peak day for cardiovascular anomalies occurred on day 9 (88.3 % of all survival embryos) with high levels also occurring on day 8 (86.5 %). Cardiovascular anomalies consisted of VSD, hypoplasia of the pulmonary trunk, coarctation of the aorta, double aortic arch, right aortic arch, riding aorta, complete transposition of the aorta, persistent atrioventricular canal, vascular ring, aberrant right subclavian artery and others. Similar anomalies, but at a lower incidence, were produced by /sup 60/Co ..gamma.. ray at dose levels of 2.0 Gy on day 10 or 11 of gestation. Cases of cleft lip and cleft palate or facial cleft were observed seventeen fetuses on day 9 of gestation (31 %). Exencephaly occurred in nine embryos treated on day 9 (16.1 %) and in one embryos treated on day 10. Tail defects appeared with treatment on day 9 with the latter predominating on day 11. The present study show that maximum resorption (52.1 %) was seen with treatment on day 8 whereas the highest rate of malformation (93.3 %) was observed with treatment on day 9. (J.P.N.).

  1. Local Sensorium, Local Cinema: György Pálfi’s Sensuous Body Politics

    Directory of Open Access Journals (Sweden)

    Kalmár György

    2014-09-01

    Full Text Available György Pálfi’s Hukkle (2002 and Taxidermia (2006 establish markedly unique cinematic styles and richly sensorial life-worlds, which function in both films as counter-discourses opposing official history, hegemonic ideologies, and conventional patterns of (cinematic understanding. In the present study I analyse the ways Pálfi’s films communicate through non-symbolic meaning, bodily discourses, and a heavy reliance on the multisensory evocation of the local sensorium (Marks and the local habitus (Bourdieu so as to create significance on the margins of established, hegemonic systems of meaning, cinema, ideology and identity.

  2. Wholesomeness of food irradiated with doses above 10 kGy

    Energy Technology Data Exchange (ETDEWEB)

    Kaferstein, F [Director, Programme of Food Safety and Food Aid, WHO, CH-1211, Geneva 27, (Switzerland)

    1998-12-31

    Strictly from the scientific point of view, no ceiling should be set for food irradiated with doses greater than the currently recommended upper level of 10 kGy by the Codex Alimentarius Commission. The food irradiation technology itself is safe to such a degree that as long as sensory qualities of food are retained and harmful microorganisms are destroyed, the actual amount of ionizing radiation applied is of secondary consideration. That was the main conclusion of a week-long meeting on high dose irradiation organized jointly by the World Health Organization (WHO), the United Nations Food and Agriculture Organization (FAO) and the International Atomic Energy Agency (IAEA). The knowledge of what can and does occur chemically in high dose irradiated foods which derives from over 50 years of research tells us that one can go as high as 75 kGy, as has already been done in some countries, and the result is the same food is safe and wholesome and nutritionally adequate. (Author)

  3. SyZyGy: A straight interferometric spacecraft system for gravity wave observations

    International Nuclear Information System (INIS)

    Estabrook, F.B.; Armstrong, J.W.; Tinto, Massimo; Folkner, William

    2003-01-01

    We consider a spaceborne gravitational wave (GW) detector formed by three spacecraft in a linear array, coherently exchanging laser beams and using the data combinations of time-delay interferometry (TDI). We previously showed how the measured time series of Doppler shifts in the six one-way laser links between spacecraft pairs in a general unequal-arm triangular configuration can be combined, using TDI, to exactly cancel the otherwise overwhelming phase noise of the lasers while retaining sensitivity to GWs. Here we apply TDI, unfolding the general triangular configuration, to the special case of a linear array of three spacecraft. We show that such an array ('SyZyGy') has, compared with an equilateral triangle GW detector of the same scale, a degraded (but non-zero) sensitivity at low frequencies [f -4 -10 -1 Hz). SyZyGy with ∼1 light-second scale could, for the same instrumental assumptions as LISA, make observations in this intermediate frequency GW band with 5σ sensitivity to sinusoidal waves ≅2.5x10 -23 in a year's integration

  4. Wholesomeness of food irradiated with doses above 10 kGy

    International Nuclear Information System (INIS)

    Kaferstein, F.

    1997-01-01

    Strictly from the scientific point of view, no ceiling should be set for food irradiated with doses greater than the currently recommended upper level of 10 kGy by the Codex Alimentarius Commission. The food irradiation technology itself is safe to such a degree that as long as sensory qualities of food are retained and harmful microorganisms are destroyed, the actual amount of ionizing radiation applied is of secondary consideration. That was the main conclusion of a week-long meeting on high dose irradiation organized jointly by the World Health Organization (WHO), the United Nations Food and Agriculture Organization (FAO) and the International Atomic Energy Agency (IAEA). The knowledge of what can and does occur chemically in high dose irradiated foods which derives from over 50 years of research tells us that one can go as high as 75 kGy, as has already been done in some countries, and the result is the same food is safe and wholesome and nutritionally adequate. (Author)

  5. Functional results of radioiodine therapy with a 300-GY absorbed dose in Graves' disease

    International Nuclear Information System (INIS)

    Willemsen, U.F.; Knesewitsch, P.; Kreisig, T.; Pickardt, C.R.; Kirsch, C.M.

    1993-01-01

    The aim of this study was to assess the results of high-dose radioiodine therapy given to 43 patients with recurrent hyperthyroidism due to Graves' disease between 1986 and 1992. We chose an intrathyroidal absorbed dose of 300 Gy and determined the applied activity individually, which ranged from 240 to 3120 MBq with a median of 752 MBq. Hperthyroidism was eliminated in 86% of cases after 3 months and in 100% after 12 months. No patient required a second radioiodine treatment. The incidnece of hyperthyroidism was 63% after 3 months and 93% after 18 months. Neither the pretherapeutic thyroid-stimulating immunoglobulin level nor the degree of co-existing endocrine ophthalmopathy was correlated with the time at which hypothyroidism developed. Patients with previous radioiodine therapy developed hypothyroidism earlier than patients with previous thyroid surgery. The results show that ablative radioiodine therapy with a 300-Gy absorbed dose is a very effective treatment of hyperthyroidism in Graves' disease, but it should be restricted to patients with recurrent hyperthyroidism combined with severe co-existing disorders or episodes of unfavourable reactions to antithyroid drugs. (orig.)

  6. Safety Evaluation of 30 kGy Irradiated Chocolate Ice Cream

    International Nuclear Information System (INIS)

    Jeon, Y.E.; Yin, X.F.; Chung, C.K.; Kang, I.J.

    2013-01-01

    This study was investigated the potential toxicity of gamma-irradiated chocolate ice cream for its future use in space. Chocolate ice cream was irradiated at a dose of 30 kGy at a temperature of -20°C. For the animal study, AIN-93G was used as a control diet and irradiated and non-irradiated chocolate ice cream diets were administered to male and female ICR mice (ten mice per group) for three months. During the experimental period, the group fed irradiated chocolate ice cream did not show any changes in appearance, behavior, mortality, body weight, organ weight, or food consumption compared to the control. Also, all biochemical parameters, including hematology profiles, erythrocyte counts, and serum biochemical values were in normal ranges. In histopathological examinations of liver and kidney tissues, there were no significant differences between the control group and the group fed irradiated chocolate ice cream. These results indicate that chocolate ice cream irradiated at 30 kGy did not cause any toxic effects and could be applied for the development of safe and hygienic space food

  7. Wholesomeness of food irradiated with doses above 10 kGy

    Energy Technology Data Exchange (ETDEWEB)

    Kaferstein, F. [Director, Programme of Food Safety and Food Aid, WHO, CH-1211, Geneva 27, (Switzerland)

    1997-12-31

    Strictly from the scientific point of view, no ceiling should be set for food irradiated with doses greater than the currently recommended upper level of 10 kGy by the Codex Alimentarius Commission. The food irradiation technology itself is safe to such a degree that as long as sensory qualities of food are retained and harmful microorganisms are destroyed, the actual amount of ionizing radiation applied is of secondary consideration. That was the main conclusion of a week-long meeting on high dose irradiation organized jointly by the World Health Organization (WHO), the United Nations Food and Agriculture Organization (FAO) and the International Atomic Energy Agency (IAEA). The knowledge of what can and does occur chemically in high dose irradiated foods which derives from over 50 years of research tells us that one can go as high as 75 kGy, as has already been done in some countries, and the result is the same food is safe and wholesome and nutritionally adequate. (Author)

  8. Effects of 15 Gy 137Cs γ-rays radiation of rat kidneys on bone metabolism

    International Nuclear Information System (INIS)

    Gao Linfeng; Wang Hongfu; Xu Peikang; Xu Aihong; Zhu Feipeng

    2003-01-01

    The work was to observe the effects of γ-rays radiation of rat kidneys on rat bone metabolism. Ten male SD rats aged 6 months were irradiated at their kidneys with 15 Gy 137 Cs γ-rays (0.91 Gy/min) and were raised for 3 months after the radiation. On collecting 24h urine of rats they were sacrificed for serum, kidney, spine, femur and tibia exams. Results show that the γ-ray irradiation could induce the pathological injuries of renal glomeruli, tubules and mesenchyme. Comparing to the control group, significant changes were found in the irradiated group in terms of their blood urea, nitrogen creatinine, urinal β-2 microglobulin, serum Ca and P, urine Ca and P, activity of serum alkaline phosphatase, 1,25 (OH) 2 D 3 , serum PTH, urine PYD/creatinine, bone mineral density (BMD) of lumbar vertebras, mineral mass of No.4 lumbar vertebra, BMD, dehydrated weight and ash weight of right femur. Marked changes were also found in bone trabecula volume, average bone trabecula thick and the ratio of nodes/points, and rate of mineralization deposition. It was concluded that renal dysfunction and metabolic bone disease might occur with the character of accelerated bone turnover and decreased bone mass

  9. Functional results of radioiodine therapy with a 300-GY absorbed dose in Graves' disease

    Energy Technology Data Exchange (ETDEWEB)

    Willemsen, U.F. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Knesewitsch, P. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Kreisig, T. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany)); Pickardt, C.R. (Dept. of Internal Medicine, Muenchen Univ. (Germany)); Kirsch, C.M. (Dept. of Nuclear Medicine, Dept. of Radiology, Muenchen (Germany))

    1993-11-01

    The aim of this study was to assess the results of high-dose radioiodine therapy given to 43 patients with recurrent hyperthyroidism due to Graves' disease between 1986 and 1992. We chose an intrathyroidal absorbed dose of 300 Gy and determined the applied activity individually, which ranged from 240 to 3120 MBq with a median of 752 MBq. Hperthyroidism was eliminated in 86% of cases after 3 months and in 100% after 12 months. No patient required a second radioiodine treatment. The incidnece of hyperthyroidism was 63% after 3 months and 93% after 18 months. Neither the pretherapeutic thyroid-stimulating immunoglobulin level nor the degree of co-existing endocrine ophthalmopathy was correlated with the time at which hypothyroidism developed. Patients with previous radioiodine therapy developed hypothyroidism earlier than patients with previous thyroid surgery. The results show that ablative radioiodine therapy with a 300-Gy absorbed dose is a very effective treatment of hyperthyroidism in Graves' disease, but it should be restricted to patients with recurrent hyperthyroidism combined with severe co-existing disorders or episodes of unfavourable reactions to antithyroid drugs. (orig.)

  10. Medial frontal white and gray matter contributions to general intelligence.

    Directory of Open Access Journals (Sweden)

    Toshiyuki Ohtani

    Full Text Available The medial orbitofrontal cortex (mOFC and rostral anterior cingulate cortex (rACC are part of a wider neural network that plays an important role in general intelligence and executive function. We used structural brain imaging to quantify magnetic resonance gray matter volume and diffusion tensor white matter integrity of the mOFC-rACC network in 26 healthy participants who also completed neuropsychological tests of intellectual abilities and executive function. Stochastic tractography, the most effective Diffusion Tensor Imaging method for examining white matter connections between adjacent gray matter regions, was employed to assess the integrity of mOFC-rACC pathways. Fractional anisotropy (FA, which reflects the integrity of white matter connections, was calculated. Results indicated that higher intelligence correlated with greater gray matter volumes for both mOFC and rACC, as well as with increased FA for left posterior mOFC-rACC connectivity. Hierarchical regression analyses revealed that DTI-derived FA of left posterior mOFC-rACC uniquely accounted for 29%-34% of the variance in IQ, in comparison to 11%-16% uniquely explained by gray matter volume of the left rACC. Together, left rACC gray matter volume and white matter connectivity between left posterior mOFC and rACC accounted for up to 50% of the variance in general intelligence. This study is to our knowledge the first to examine white matter connectivity between OFC and ACC, two gray matter regions of interests that are very close in physical proximity, and underscores the important independent contributions of variations in rACC gray matter volume and mOFC-rACC white matter connectivity to individual differences in general intelligence.

  11. Health-Related Quality of Life in Patients With Locally Advanced Prostate Cancer After 76 Gy Intensity-Modulated Radiotherapy vs. 70 Gy Conformal Radiotherapy in a Prospective and Longitudinal Study

    International Nuclear Information System (INIS)

    Lips, Irene; Dehnad, Human; Kruger, Arto Boeken; Moorselaar, Jeroen van; Heide, Uulke van; Battermann, Jan; Vulpen, Marco van

    2007-01-01

    Purpose: To compare quality of life (QoL) after 70 Gy conformal radiotherapy with QoL after 76 Gy intensity-modulated radiotherapy (IMRT) in patients with locally advanced prostate carcinoma. Methods and Materials: Seventy-eight patients with locally advanced prostate cancer were treated with 70 Gy three-field conformal radiotherapy, and 92 patients received 76 Gy IMRT with fiducial markers for position verification. Quality of life was measured by RAND-36, the European Organization for Research and Treatment of Cancer core questionnaire (EORTC QLQ-C30(+3)), and the prostate-specific EORTC QLQ-PR25, before radiotherapy (baseline) and 1 month and 6 months after treatment. Quality of life changes in time (baseline vs. 1 month and baseline vs. 6 months) of ≥10 points were considered clinically relevant. Results: Differences between the treatment groups for QoL changes over time occurred in several QoL domains. The 76-Gy group revealed no significant deterioration in QoL compared with the 70-Gy group. The IMRT 76-Gy group even demonstrated a significantly better change in QoL from baseline to 1 month in several domains. The conformal 70-Gy group revealed temporary deterioration in pain, role functioning, and urinary symptoms; for the IMRT 76-Gy group a better QoL in terms of change in health existed after 1 month, which persisted after 6 months. For both treatment groups temporary deterioration in physical role restriction occurred after 1 month, and an improvement in emotional role restriction occurred after 6 months. Sexual activity was reduced after treatment for both groups and remained decreased after 6 months. Conclusions: Intensity-modulated radiotherapy and accurate position verification seem to provide a possibility to increase the radiation dose for prostate cancer without deterioration in QoL

  12. Ionizing radiation effects of Cobalt-60 on the physical-chemical, sensorial and microbiological of bread with addition of linseed (Linum usitatissimum); Efeitos da radiacao ionizante de cobalto-60 nas caracteristicas fisico-quimicas sensoriais e microbiolgicas de paes com adicao de linhaca (Linum usitatissimum)

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Neila Camargo de

    2011-07-01

    The incorporation of functional ingredients on breading products has grown very much lately, because of the preoccupation with the consumers' health. The linseed has awakened the interest by its high level of fiber, lignin, omega-3 and antioxidants compounds. The objective of the present work is evaluate the ionizing radiation effect of {sup 60}Co on the physical-chemical, sensorial and microbiological characteristics of bread with addition of different concentration of brown linseed. There were elaborated 3 types of bread: French roll, form bread prepared with the mixture and form bread produced with conventional ingredients. It was added smashed brown linseed on the bread dough, with concentrations of 8% and 12%. After the preparation, the three kinds of bread packed with polypropylene packages and taken to the IPEN/USP (Institute of Nuclear Energetic Research/University of São Paulo) and irradiated with doses of 6, 8 and 10 kGy. Treatments were elaborated without the addition of linseed and without irradiation, for control, totalizing 12 distinct treatments, to each bread formula tested. Chemical analyses were made (centesimal composition, anti-nutritional compounds, anti-oxidant activity, glycemic index, fat acids, complex B vitamins and minerals); physical analyses (cooking index, volume, color and water activity); sensorial analyses (preference tests and Descriptive Quantitative Analysis - ADQ); microbiological analysis and a survey about irradiated products. It could be seen that the addition of linseed was efficient to increase the level of alimentary fiber and the level of lipids on the 3 bread formula. The three kinds of bread that received the linseed addition and that were not irradiated presented increase on the level of total phenolic; however, when the samples which received the linseed addition were submitted to the irradiation process, it could be noticed the decrease of the antioxidant capacity. There was an increase on the level of omega-3

  13. Longitudinal Study of Gray Matter Changes in Parkinson Disease.

    Science.gov (United States)

    Jia, X; Liang, P; Li, Y; Shi, L; Wang, D; Li, K

    2015-12-01

    The pathology of Parkinson disease leads to morphological brain volume changes. So far, the progressive gray matter volume change across time specific to patients with Parkinson disease compared controls remains unclear. Our aim was to investigate the pattern of gray matter changes in patients with Parkinson disease and to explore the progressive gray matter volume change specific to patients with Parkinson disease with disease progression by using voxel-based morphometry analysis. Longitudinal cognitive assessment and structural MR imaging of 89 patients with Parkinson disease (62 men) and 55 healthy controls (33 men) were from the Parkinson's Progression Markers Initiative data base, including the initial baseline and 12-month follow-up data. Two-way analysis of covariance was performed with covariates of age, sex, years of education, imaging data from multiple centers, and total intracranial volume by using Diffeomorphic Anatomical Registration Through Exponentiated Lie Algebra tool from SPM8 software. Gray matter volume changes for patients with Parkinson disease were detected with decreased gray matter volume in the frontotemporoparietal areas and the bilateral caudate, with increased gray matter volume in the bilateral limbic/paralimbic areas, medial globus pallidus/putamen, and the right occipital cortex compared with healthy controls. Progressive gray matter volume decrease in the bilateral caudate was found for both patients with Parkinson disease and healthy controls, and this caudate volume was positively associated with cognitive ability for both groups. The progressive gray matter volume increase specific to the patients with Parkinson disease was identified close to the left ventral lateral nucleus of thalamus, and a positive relationship was found between the thalamic volume and the tremor scores in a subgroup with tremor-dominant patients with Parkinson disease. The observed progressive changes in gray matter volume in Parkinson disease may provide

  14. Identification of microbial isolates from vacuum-packaged ground pork irradiated at 1 kGy

    International Nuclear Information System (INIS)

    Ehioba, R.M.; Kraft, A.A.; Molins, R.A.; Walker, H.W.; Olson, D.G.; Subbaraman, G.; Skowronski, R.P.

    1988-01-01

    Bacterial cultures from irradiated (1 kGy) and nonirradiated, vacuum-packaged ground pork held at 5 0 C were isolated and characterized over a 12-day storage period. The initial flora of the meat was composed mostly of Pseudomonas sp., and Enterobacter sp. Although the microflora of nonirradiated samples gradually shifted from Gram-negative to Gram-positive microorganisms, 76% of the isolates were characterized as Gram-negative at the onset of spoilage (9 days at 5 0 C). In contrast, the irradiated ground pork microflora was mainly Gram-positive (66%) shortly after irradiation and increased to 97% after 9 days at 5 0 C. A total of 720 isolates were identified to genus

  15. The affect of bone marrow cell biomechanical characteristics to 6 Gy γ irradiation-injured mice

    International Nuclear Information System (INIS)

    Pu Xiaoyun; Chen Xiaoli; Pan Jing; Li Zhaoquan; Deng Jun; Huang Hui; Ye Yong

    2004-01-01

    Objective: To explore the change of bone marrow cell biomechanical characteristics in radiation-injured mice and the influencing factors. Methods: Male Kunming mice were exposed to total body irradiation of 6 Gy γ-rays from a 60 Co source. Electrophoresis, DPH probe-micropore filter, and adhesion rate methods were used to detect cell surface charge, membrane microviscosity, cell deformability, and cell adhesion, respectively. Results: The deformability, adhesiveness and cell surface charges of bone marrow cells (including hematopoietic cells and stromal cells) were dramatically decreased, but membrane microviscosity was obviously increased after irradiation on 1 d, 3 d and 7 d. Conclusion: The biomechanical characteristics of bone marrow cells are obviously changed after radiation injury. It might be one of the reasons of hematopoietic failure after irradiation. (authors)

  16. Pierre Gy's sampling theory and sampling practice heterogeneity, sampling correctness, and statistical process control

    CERN Document Server

    Pitard, Francis F

    1993-01-01

    Pierre Gy's Sampling Theory and Sampling Practice, Second Edition is a concise, step-by-step guide for process variability management and methods. Updated and expanded, this new edition provides a comprehensive study of heterogeneity, covering the basic principles of sampling theory and its various applications. It presents many practical examples to allow readers to select appropriate sampling protocols and assess the validity of sampling protocols from others. The variability of dynamic process streams using variography is discussed to help bridge sampling theory with statistical process control. Many descriptions of good sampling devices, as well as descriptions of poor ones, are featured to educate readers on what to look for when purchasing sampling systems. The book uses its accessible, tutorial style to focus on professional selection and use of methods. The book will be a valuable guide for mineral processing engineers; metallurgists; geologists; miners; chemists; environmental scientists; and practit...

  17. Cardiac ultrastructural changes in rats following 250 Gy whole body. gamma. -irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Guo; Mingyue, Zhu; Zhiqin, Zhao

    1985-10-01

    Sixteen rats were whole body irradiated with 250 Gy of /sup 60/Co ..gamma..-rays, killed at different intervals after exposure, and then observed by electron microscope. We found lysis of part of myofilaments in specimen obtained at 10 minutes after exposure, and resolution of Z-band at 30 minutes after exposure. These changes were more significant in sections at 12 hours postirradiation, but there also appeared cell regeneration at the same time. The vascular changes were more obvious with the endothelial cytoplasma projected in capillary lumen, nearly obstructing it. All of above described changes may be found in hematologic or intestinal forms of radiation sickness, but they must take place more late after exposure. In cardiovascular form, however, these changes were found as early as 10-30 minutes after exposure; this is a special feature helpful to diagnosis.

  18. Study of differential gene expression in human hepatocyte exposed to 50 cGy γ ray

    International Nuclear Information System (INIS)

    Wen Jianhua; Li Jianguo; Tian Huancheng; Li Yanling; Wang Xiaoli; Zuo Yanhui

    2008-01-01

    The study analyzed the differential transcriptional profile of the normal human hepatic cell and the human hepatic cell radiated with 50 cGy γ ray by gene chip technique. The results showed that there were 614 differentially expressed genes among 14 112 human genes analyzed, in which 521 genes were up-regulated and 93 genes down-regulated. These genes are associated with mitochondrial regulation, homo sapiens hepatitis A virus cellular receptor, tumor necrosis factor, cell cycle regulation, kinase and zinc finger protein etc. RT-PCR results indicated that up-regulated expression of gene HAVcr-1, HAVcr-2, MFTC, MOAP1 and down-regulated expression of gene TRIP12, DCN were consistent with gene chip data. (authors)

  19. Substantiation of 25 kGy (by use of VDmax25 method) as the sterilization dose

    International Nuclear Information System (INIS)

    2011-01-01

    The International standards for radiation sterilization require evidence of the effectiveness of a minimum sterilization dose of 25 kGy but do not provide detailed guidance on how this evidence can be generated. Although many of the procedural elements in method VD m ax are similar to those of Method 1 of ANSI/AAMI/ISO 11137-2, there are differences that require elaboration. In this project, test procedure of VD m ax 2 5 method was established and then validated in Radiation Microbiology Laboratory (RML) test conditions. Beside, this method has been applied successfully for two years in order to reply the demand of the manufacturer firms as routine test service. In the near future, RML will be the only accredited laboratory in Turkey on 'validation of radiation sterilization' standard (ANSI/AAMI/ISO 11137-2: 2006) that consists of VD m ax 2 5 method

  20. Low-dose (10-Gy) total skin electron beam therapy for cutaneous T-cell lymphoma

    DEFF Research Database (Denmark)

    Kamstrup, Maria R; Gniadecki, Robert; Iversen, Lars

    2015-01-01

    a total dose of 10 Gy in 10 fractions. Data from 10 of these patients were published previously but were included in the current pooled data analysis. Outcome measures were response rate, duration of response, and toxicity. RESULTS: The overall response rate was 95% with a complete cutaneous response......PURPOSE: Cutaneous T-cell lymphomas (CTCLs) are dominated by mycosis fungoides (MF) and Sézary syndrome (SS), and durable disease control is a therapeutic challenge. Standard total skin electron beam therapy (TSEBT) is an effective skin-directed therapy, but the possibility of retreatments...... or a very good partial response rate (response was 174 days (5.8 months; range: 60-675 days). TSEBT-related acute adverse events (grade 1 or 2) were observed in 60% of patients. CONCLUSIONS...

  1. Morphometric changes of pulmonary tissues after 20 Gy external irradiation of rat chest

    International Nuclear Information System (INIS)

    Cao Zhenshan; Ye Changqing; Yuan Lizhen

    1996-01-01

    The changes in the main parameters of the lungs at different periods of early stage after local 20 Gy external irradiation of the lungs were measured with morphometric method. The results indicated that the walls of pulmonary arterioles and venules thickened and the vascular permeability index (area of vascular lumen/total area of blood vessel) decreased 7 days after irradiation (P 2 , r = -0.919), indicating that narrowing of the vascular lumen was the result of thickening of the vascular wall. Fifteen days after irradiation, the pulmonary alveolar wall thickened, the area of alveolar cavity decreased and the area of pulmonary interstitial space increased (P<0.01). Electron microscopic examination demonstrated profuse exudation surrounding the microvessels, obvious evacuation of pulmonary type-II cells and increase in cellular types and quantity of pulmonary tissues

  2. QCA Gray Code Converter Circuits Using LTEx Methodology

    Science.gov (United States)

    Mukherjee, Chiradeep; Panda, Saradindu; Mukhopadhyay, Asish Kumar; Maji, Bansibadan

    2018-04-01

    The Quantum-dot Cellular Automata (QCA) is the prominent paradigm of nanotechnology considered to continue the computation at deep sub-micron regime. The QCA realizations of several multilevel circuit of arithmetic logic unit have been introduced in the recent years. However, as high fan-in Binary to Gray (B2G) and Gray to Binary (G2B) Converters exist in the processor based architecture, no attention has been paid towards the QCA instantiation of the Gray Code Converters which are anticipated to be used in 8-bit, 16-bit, 32-bit or even more bit addressable machines of Gray Code Addressing schemes. In this work the two-input Layered T module is presented to exploit the operation of an Exclusive-OR Gate (namely LTEx module) as an elemental block. The "defect-tolerant analysis" of the two-input LTEx module has been analyzed to establish the scalability and reproducibility of the LTEx module in the complex circuits. The novel formulations exploiting the operability of the LTEx module have been proposed to instantiate area-delay efficient B2G and G2B Converters which can be exclusively used in Gray Code Addressing schemes. Moreover this work formulates the QCA design metrics such as O-Cost, Effective area, Delay and Cost α for the n-bit converter layouts.

  3. Evaluation of Accelerated Graphitic Corrosion Test of Gray Cast Iron

    International Nuclear Information System (INIS)

    Kim, Jeong Hyeon; Hong, Jong Dae; Chang Heui; Na, Kyung Hwan; Lee, Jae Gon

    2011-01-01

    In operating nuclear power plants, gray cast iron is commonly used as materials for various non-safety system components including pipes in fire water system, valve bodies, bonnets, and pump castings. In such locations, operating condition does not require alloy steels with excellent mechanical properties. But, a few corrosion related degradation, or graphitic corrosion is frequently occurred to gray cast iron during the long-term operation in nuclear power plant. Graphitic corrosion is selective leaching of iron from gray cast iron, where iron gets removed and graphite grains remain intact. In U.S.A., one-time visual inspection and hardness measurement are required from regulatory body to detect the graphitic corrosion for the life extension evaluation of the operating nuclear power plant. In this study, experiments were conducted to make accelerated graphitic corrosion of gray cast iron using electrochemical method, and hardness was measured for the specimens to establish the correlation between degree of graphitic corrosion and surface hardness of gray cast iron

  4. Higher than standard radiation doses (≥72 Gy) with or without androgen deprivation in the treatment of localized prostate cancer

    International Nuclear Information System (INIS)

    Kupelian, Patrick A.; Mohan, Dasarahally S.; Lyons, Janice; Klein, Eric A.; Reddy, Chandana A.

    2000-01-01

    Purpose: To study the effect on biochemical relapse-free survival (bRFS) and clinical disease-free survival of radiation doses delivered to the prostate and periprostatic tissues for localized prostate cancer. Methods and Materials: A total of 1041 consecutive localized prostate cancer cases treated with external beam radiotherapy (RT) at our institution between 7/86 and 2/99 were reviewed. All cases had available pretreatment parameters including pretreatment prostate-specific antigen (iPSA), biopsy Gleason score (bGS), and clinical T stage. The median age was 69 years. Twenty-three percent of cases (n = 238) were African-American. The distribution by clinical T stage was as follows: T1 in 365 cases (35%), T2 in 562 cases (54%), and T3 in 114 cases (11%). The median iPSA level was 10.1 ng/ml (range: 0.4-692.9). The distribution by biopsy Gleason score (bGS) was as follows: ≤6 in 580 cases (56%) and ≥7 in 461 cases (44%). Androgen deprivation (AD) in the adjuvant or neoadjuvant setting was given in 303 cases (29%). The mean RT dose was 71.9 Gy (range: 57.6-78.0 Gy). The median RT dose was 70.2 Gy, with 458 cases (44%) receiving at least 72.0 Gy. The average dose in patients receiving <72 Gy was 68.3 Gy (median 68.4) versus 76.5 Gy (median 78.0) for patients receiving ≥72 Gy. The mean follow-up was 38 months (median 33 months). The number of follow-up prostate-specific antigen (PSA) levels available was 5998. Results: The 5- and 8-year bRFS rates were 61% (95% CI 55-65%) and 58% (95% CI 51-65%), respectively. The 5-year bRFS rates for patients receiving radiation doses ≥72 Gy versus <72 Gy were 87% (95% CI 82-92%) and 55% (95% CI 49-60%), respectively. The 8-year bRFS rates for patients receiving radiation doses ≥72 Gy versus <72 Gy were 87% (95% CI 82-92%) and 51% (95% CI 44-58%), respectively (p < 0.001). A multivariate analysis of factors affecting bRFS was performed using the following parameters: age (continuous variable), race, T-stage (T1-T2 vs. T3

  5. Quality of fresh-cut Iceberg lettuce and spinach irradiated at doses up to 4 kGy

    International Nuclear Information System (INIS)

    Fan Xuetong; Guan Wenqiang; Sokorai, Kimberly J.B.

    2012-01-01

    Fresh-cut Iceberg lettuce packaged in modified atmosphere packages and spinach in perforated film bags were irradiated with gamma rays at doses of 0, 1, 2, 3, and 4 kGy. After irradiation, the samples were stored for 14 days at 4 °C. O 2 levels in the packages of fresh-cut Iceberg lettuce decreased and CO 2 levels increased with increasing radiation dose, suggesting that irradiation increased respiration rates of lettuce. Tissue browning of irradiated cut lettuce was less severe than that of non-irradiated, probably due to the lower O 2 levels in the packages. However, samples irradiated at 3 and 4 kGy had lower maximum force and more severe sogginess than the non-irradiated control. In addition, ascorbic acid content of irradiated lettuce was 22–40% lower than the non-irradiated samples after 14 days of storage. The visual appearance of spinach was not affected by irradiation even at a dose of 4 kGy. Consumer acceptance suggested that more people would dislike and would not buy spinach that was treated at 3 and 4 kGy as compared to the non-irradiated sample. Overall, irradiation at doses of 1 and 2 kGy may be employed to enhance microbial safety of fresh-cut Iceberg lettuce and spinach while maintaining quality. - Highlights: ▶ Headspace composition in the modified atmosphere packages of cut lettuce was affected by irradiation. ▶ Fresh-cut lettuce in adapted atmosphere could tolerate 1 or 2 kGy rays without quality deterioration in look and texture. ▶ Lettuce irradiated at doses higher than 2 kGy developed sogginess. ▶ Irradiated spinach maintained a good appearance at doses of 3 and 4 kGy. ▶ Higher doses (3 and 4 kGy) of radiation decreased consumers' likingness and purchase intent of irradiated spinach.

  6. Prefrontal gray matter volume mediates genetic risks for obesity.

    Science.gov (United States)

    Opel, N; Redlich, R; Kaehler, C; Grotegerd, D; Dohm, K; Heindel, W; Kugel, H; Thalamuthu, A; Koutsouleris, N; Arolt, V; Teuber, A; Wersching, H; Baune, B T; Berger, K; Dannlowski, U

    2017-05-01

    Genetic and neuroimaging research has identified neurobiological correlates of obesity. However, evidence for an integrated model of genetic risk and brain structural alterations in the pathophysiology of obesity is still absent. Here we investigated the relationship between polygenic risk for obesity, gray matter structure and body mass index (BMI) by the use of univariate and multivariate analyses in two large, independent cohorts (n=330 and n=347). Higher BMI and higher polygenic risk for obesity were significantly associated with medial prefrontal gray matter decrease, and prefrontal gray matter was further shown to significantly mediate the effect of polygenic risk for obesity on BMI in both samples. Building on this, the successful individualized prediction of BMI by means of multivariate pattern classification algorithms trained on whole-brain imaging data and external validations in the second cohort points to potential clinical applications of this imaging trait marker.

  7. THE CORROSION BEHAVIOR AND WEAR RESISTANCE OF GRAY CAST IRON

    Directory of Open Access Journals (Sweden)

    Lina F. Kadhim

    2018-01-01

    Full Text Available Gray cast iron has many applications as pipes , pumps and valve bodies where it has influenced by heat and contact with other solutions . This research has studied the corrosion behavior and Vickers hardness of gray cast iron by immersion in four strong alkaline solutions (NaOH, KOH, Ca(OH2, LiOHwith three concentrations (1%,2%,3% of each solution. Dry sliding wear has carried out before and after the heat treatments (stress relief ,normalizing, hardening and tempering. In this work ,maximum wear strength has obtained at tempered gray cast iron and minimum corrosion rate has obtained in LiOH solution by forming protective white visible oxide layer.

  8. The ``gray cortex``: an early sign of stress fracture

    Energy Technology Data Exchange (ETDEWEB)

    Mulligan, M.E. [Dept. of Radiology, Univ. of Maryland Medical Center, Baltimore, MD (United States)

    1995-04-01

    The purpose of this report is to describe an early radiographic sign of stress fracture, the ``gray cortex.`` The imaging findings in three patients with tibial stress fractures were reviewed. The ``gray cortex`` sign was evident on the initial conventional radiographs in all three cases. It was prospectively reported as a sign of stress fracture in two patients and was evident on the initial radiographs (taken elsewhere) of the third patient, who was referred for additional workup of a possible neoplasm. Special imaging studies (technetium-99m bone scan, computed tomography, and magnetic resonance imaging) confirmed the diagnosis in all three cases. (orig.)

  9. The ''gray cortex'': an early sign of stress fracture

    International Nuclear Information System (INIS)

    Mulligan, M.E.

    1995-01-01

    The purpose of this report is to describe an early radiographic sign of stress fracture, the ''gray cortex.'' The imaging findings in three patients with tibial stress fractures were reviewed. The ''gray cortex'' sign was evident on the initial conventional radiographs in all three cases. It was prospectively reported as a sign of stress fracture in two patients and was evident on the initial radiographs (taken elsewhere) of the third patient, who was referred for additional workup of a possible neoplasm. Special imaging studies (technetium-99m bone scan, computed tomography, and magnetic resonance imaging) confirmed the diagnosis in all three cases. (orig.)

  10. Wave-splitting in the bistable Gray-Scott model

    DEFF Research Database (Denmark)

    Rasmussen, K.E.; Mazin, W.; Mosekilde, Erik

    1996-01-01

    The Gray-Scott model describes a chemical reaction in which an activator species grows autocatalytically on a continuously fed substrate. For certain feed rates and activator life times the model shows the coexistence of two homogeneous steady states. The blue state, where the activator concentra......The Gray-Scott model describes a chemical reaction in which an activator species grows autocatalytically on a continuously fed substrate. For certain feed rates and activator life times the model shows the coexistence of two homogeneous steady states. The blue state, where the activator...

  11. [Surface electromyography signal classification using gray system theory].

    Science.gov (United States)

    Xie, Hongbo; Ma, Congbin; Wang, Zhizhong; Huang, Hai

    2004-12-01

    A new method based on gray correlation was introduced to improve the identification rate in artificial limb. The electromyography (EMG) signal was first transformed into time-frequency domain by wavelet transform. Singular value decomposition (SVD) was then used to extract feature vector from the wavelet coefficient for pattern recognition. The decision was made according to the maximum gray correlation coefficient. Compared with neural network recognition, this robust method has an almost equivalent recognition rate but much lower computation costs and less training samples.

  12. Role of NO in adrenergic regulation of the heart after chronic gamma irradiation in 1 Gy dose

    International Nuclear Information System (INIS)

    Suvorova, T.A.; Lobanok, L.M.

    2005-01-01

    Chronic irradiation in 1 Gy dose significantly decreased adrenoreactivity of the heart. Modification of NO-mediated mechanisms plays an important role in radiation-induced changes of adrenergic control of heart functional activity and coronary flow. (authors)

  13. eGY-Africa: addressing the digital divide for science in Africa

    Science.gov (United States)

    Baki, Paul; Nguno, Anna; Barton, Charles; Amaeshi, Larry; Tenthani, Chifundo; Petitdidier, Monique; Cottrell, Les

    2013-04-01

    Adoption of information and communication technologies and access to the Internet is expanding in Africa, but because of the rapid growth elsewhere, a Digital Divide between Africa and the rest of the world exists. In many sub-Saharan African countries, education and research sector suffers some of the worst deficiencies in access to the Internet, despite progress in the development of NRENs - National Research and Education (cyber) Networks. By contrast, it is widely acknowledged in policy statements from the African Union, the UN, and others that strength in this very sector provides the key to meeting and sustaining Millennium Development Goals. Developed countries with effective cyber-capabilities proclaim the benefits to rich and poor alike arising from the Information Revolution. This is still a dream for many scientists in African institutions. As the world of science becomes increasingly Internet-dependent, so they become increasingly isolated. eGY-Africa is a bottom-up initiative by African scientists and their collaborators to try to reduce this digital divide by a campaign of advocacy for better institutional facilities. Four approaches are being taken. The present status of Internet services, problems, and plans are being mapped via a combination of direct measurement of Internet performance (the PingER Project) and a questionnaire-based survey. Information is being gathered on policy statements and initiatives aimed at reducing the digital divide, which can be used for arguing the case for better Internet facilities. Groups of concerned scientists are being formed at the national, regional levels in Africa, building on existing networks as much as possible. Opinion in the international science community is being mobilized. Finally, and perhaps most important of all, eGY-Africa is seeking to engage with the many other programs, initiatives, and bodies that share the goal of reducing the digital divide - either as a direct policy objective, or indirectly

  14. Hyperfractionated radiotherapy (2100 cGY) for stage 4 neuroblastoma as part of intensive multimodality therapy

    International Nuclear Information System (INIS)

    Gollamudi, S.V.; Kushner, B.H.; Merchant, T.E.; LaQuaglia, M.; Lindsley, K.; Rosenfield, N.; Abramson, S.; Kramer, K.; Cheung, N.K.V.

    1997-01-01

    PURPOSE: To retrospectively evaluate the role of hyperfractionated radiotherapy to the primary site following induction chemotherapy and aggressive surgical resection in patients (pts) with stage 4 neuroblastoma. MATERIALS AND METHODS: 48 previously untreated children (median age at diagnosis 3 yo, range 1-10 yo) with stage 4 neuroblastoma achieved a complete-, near-complete-, or partial-remission after multimodality therapy (protocol N4: 6 pts, N5: 7 pts, N6: 27 pts, or N7: 8 pts). All protocols included a regimen consisting of dose-intensive multiagent chemotherapy, maximal surgical debulking, followed by hyperfractionated radiotherapy. Most pts then underwent consolidation with either autologous marrow transplantation (N4 and N5), or immunotherapy (N6 and N7) with radioimmunotherapy (N7). Of 48 pts, 46 had microscopic disease at the primary site prior to beginning radiotherapy (45 underwent gross total resection of the primary, and one had no residual primary disease after chemotherapy alone). One pt had a partial resection, and one remained unresectable after mutimodality therapy. The pre-chemotherapy volume of the primary tumor and regional lymph nodes were irradiated to a total dose of 2100cGy delivered twice-daily in 150 cGy fractions over 7 treatment days. RESULTS: With a median follow-up of 32.5 months (range= 8-145 months), local-regional control was achieved in 44 of the 48 pts. Of the pts who are progression-free, median follow-up was 53.5 months. Overall, 24 of 48 pts progressed, three with local-regional recurrence as the first site of relapse, one with distant failure first and subsequent local-regional recurrence, and 21 with distant failure only. The probability of local-regional control at 32 months was 83%. One of the four pts with local-regional relapse never achieved a complete remission with either systemic therapy, surgical resection or radiotherapy. The progression-free survival at 32 months was 46%. Median time to overall progression was 16

  15. eGY-Africa: Addressing the Digital Divide for Science in Africa

    Energy Technology Data Exchange (ETDEWEB)

    Barton, C.E.; /Australian Natl. U., Canberra; Amory-Mazaudier, C.; /Lab.Phys.Plasmas, Saint Maur des Fosses; Barry, B.; /Assoc.African Univ., Accra; Chukwuma; /Olabisi Onabanjo U.; Cottrell, R.L.; /SLAC; Kalim, U.; /Pakistan Natl. U.; Mebrahtu, A.; /Mekelle U.; Petitdidier, M.; /Lab. d' Atmos., Velizy; Rabiu, B.; /Federal Tech. U., Akure; Reeves, C.; /Earthworks bv, Delft

    2010-06-16

    Adoption of information and communication technologies and access to the Internet is expanding in Africa, but because of the rapid growth elsewhere, a Digital Divide between Africa and the rest of the world exists, and the gap is growing. In many sub-Saharan African countries, education and research sector suffers some of the worst deficiencies in access to the Internet, despite progress in development of NRENs - National Research and Education (cyber) Networks. By contrast, it is widely acknowledged in policy statements from the African Union, the UN, and others that strength in this very sector provides the key to meeting and sustaining Millennium Development Goals. Developed countries with effective cyber-capabilities proclaim the benefits to rich and poor alike arising from the Information Revolution. This is but a dream for many scientists in African institutions. As the world of science becomes increasingly Internet-dependent, so they become increasingly isolated. eGY-Africa is a bottom-up initiative by African scientists and their collaborators to try to reduce this Digital Divide by a campaign of advocacy for better institutional facilities. Four approaches are being taken. The present status of Internet services, problems, and plans are being mapped via a combination of direct measurement of Internet performance (the PingER Project) and a questionnaire-based survey. Information is being gathered on policy statements and initiatives aimed at reducing the Digital Divide, which can be used for arguing the case for better Internet facilities. Groups of concerned scientists are being formed at the national, regional levels in Africa, building on existing networks as much as possible. Opinion in the international science community is being mobilized. Finally, and perhaps most important of all, eGY-Africa is seeking to engage with the many other programs, initiatives, and bodies that share the goal of reducing the Digital Divide - either as a direct policy

  16. Graves' disease and radioiodine therapy. Is success of ablation dependent on the achieved dose above 200 Gy?

    Energy Technology Data Exchange (ETDEWEB)

    Kobe, C.; Eschner, W.; Sudbrock, F.; Weber, I.; Marx, K.; Dietlein, M.; Schicha, H. [Dept. of Nuclear Medicine, Univ. of Cologne (Germany)

    2008-07-01

    Aim: this study was performed to determine the results of ablative radioiodine therapy (RIT) when the achieved dose in the thyroid was above 200 Gy and to characterize predictive factors for treatment outcome. Patients, methods: a total of 571 consecutive patients were observed for 12 months between July 2001 and June 2004. Inclusion criteria were a confirmed diagnosis Groves' disease, compensation of hyperthyroidism and withdrawal of antithyroid drugs two days before preliminary radioiodine-testing and RIT. The intended dose was 250 Gy and the therapeutically achieved dose was calculated from serial uptake measurements. The end-point measure was thyroid function 12 months after RIT; success was defined as elimination of hyperthyroidism. The relation between success rate and the achieved dose, thyroid volume, age and sex of patients, TSH- and TRAb-values and presence of ophthalmopathy was analysed. Results: relief from hyperthyroidism was achieved in 96% of patients who received more than 200 Gy, even for thyroid volumes >40 ml. The success of ablative RIT was not influenced by age or sex of patients, or by TSH- or TRAb values or concomitant ophthalmopathy. The mean achieved dose in the thyroid was 298 Gy with a standard deviation of 74.6 Gy. Conclusion: to achieve a dose of over 200 Gy with the above standard deviation, we recommend calculating on intended dose of 250 Gy and using a dosimetric approach with early and late uptake values in the radioiodine test, to allow early therapeutic intervention should the posttherapeutic thyroid dose fall unexpectedly below 200 Gy. (orig.)

  17. Lack of evidence for increased tolerance of rat spinal cord with decreasing fraction doses below 2 Gy

    International Nuclear Information System (INIS)

    Ang, K.K.; van der Kogel, A.J.; van der Schueren, E.

    1985-01-01

    The radiation tolerance of the spinal cord, both in man and in rats, has been shown to depend strongly on the size of the dose per fraction. With fraction doses down to about 2 Gy, the spinal cord tolerance can be predicted by a modified Ellis formula. More recently alternative isoeffect formulas were based on the linear-quadratic (LQ) model of cell survival where the effect of dose fractionation is characterized by the ratio α/β which varies from tissue to tissue. For the spinal cord, as well as for other late responding tissues, the ratio α/β is small, in contrast to most acutely responding tissues. Both the Ellis-type formula, and to a lesser extent the LQ-model, predict a continuously increasing tolerance dose with decreasing fraction size. From previous experiments on the rat cervical spinal cord with doses per fraction down to about 2 Gy, the ratio α/β was determined to be 1.7 Gy, and the LQ-model would predict a rise in tolerance with a reduction in fraction size to far below 2 Gy. Based on these predictions clinical studies have been initiated assuming a significantly increased tolerance by reduction of fraction size to about 1 Gy. However, in the present experiments no evidence was found for such an increase in tolerance with fraction sizes below 2 Gy

  18. Clotting mechanism in beagles irradiated by 4.5 Gy γ-rays

    International Nuclear Information System (INIS)

    Zhao Zhenhu; Wang Ning; Li Ming; Xing Shuang; Huang Haixiao; Ou Hongling; Xiong Guolin; Zhao Yanfang; Xie Ling; Wang Jinxiang; Miao Jingcheng; Zhu Nankang; Zhang Xueguang; Luo Qingliang; Cong Yuwen

    2010-01-01

    Objective: To explore the clotting mechanism in beagles irradiated by 4.5 Gy γ-rays after treatment with supportive care, or supportive care and combined cytokines. Methods: Sixteen beagles were divided into irradiation control group, Supportive care group and combined cytokines treatment group. Platelet aggregation test, thrombelastography (TEG) and the time measurement were analyzed in vitro. Results: In irradiation group and supportive care group, the platelet aggregation rates in beagles were decreased markedly and the k value of TEG was increased 7 d post-irradiation, while those indexes in combined cytokines treatment group changed little. At 14 d post-irradiation, each parameter of TEG in irradiated group changed obviously. The values of r, k, r + k and M were elevated significantly, clotting time and the maximum coagulation time of thrombus delayed, the Ma value was decreased markedly, and the maximum elasticity amplitude of thrombus was diminished. All parameters in combined cytokines treatment group were better than those in supportive care group. The thrombin time was prolonged obviously in irradiated group 14 d post-irradiation, while the thrombin time was the longest at 2-3 weeks post irradiation in supportive care group and combined cytokines treatment group (P>0.05). Conclusions: Cytokines could improve the platelet aggregation and the blood clotting functions of beagles suffering from acute radiation sickness. (authors)

  19. Alpha-methyl-homocysteine thiolactone protects lung of BALB/c mice irradiated with 6 Gy

    International Nuclear Information System (INIS)

    Lubec, G.; Tichatschek, E.; Foltinova, J.; Leplawy, T.; Mallinger, R.; Getoff, N.

    1996-01-01

    The radiation protective activity of intaperitoneally administered alpha-methyl-homocysteine thiolactone (α-MHCTL); 100 mg/kg body weight) in female BALB/c mice and such treated with cysteine treated (100 mg/kg body weight), using unirradiated and placebo treated irradiated mice were tested as controls. 6Gy whole body irradiated was applied and after a period of three weeks the animals were sacrificed and lungs were taken for morphometry and the determination of o-tyrosine. Septal areas were highest in the irradiated, placebo treated mice (68.67 + 9.82% septal area to total area) and lowest in the α-MHCTL treated irradiated mice (55.67 + 11.29%), significant at the p < 0.05 level. Morphometric data were accompanied by highest levels of o-tyrosine, a reliable parameter for OH-attack, in the irradiated, placebo treated group with 1.87 + 0.40 μM/g lung tissue and 0.32 + 0.13 μM/g lung tissue in the αMHCTL treated group; the statistical difference was significant. Significant radiation protection in the mammalian system at the morphological and biochemical level were found. The potent effect could be explained by the influence of alpha-alkylation in homocysteine thiolactone (HCTL) which renders amino acids unmetabolizeable, nontoxic, increases lipophilicity and therefore improving permeability through membranes. The present report confirms morphological data on the radiation protective activity of this interesting thiol compound. (Author)

  20. Behavioural consequences of an 8 Gy total body irradiation in mice: Regulation by interleukin-4

    International Nuclear Information System (INIS)

    Van der Meeren, A.; Lebaron-Jacobs, L.

    2001-01-01

    The effects of an 8 Gy γ total body irradiation (TBI) on exploration and locomotion activities as well as temperature were studied in C57BL6/J mice. Survival, body weight, and blood cell counts were also assessed in irradiated mice treated with placebo or interleukin (IL)-4. The efficacy of IL-4 treatment on improvement in exploration activity was evaluated. The study was carried out from 3 h to 30 days following exposure. Our results showed a biphasic response to irradiation concerning the exploration activity of mice. Irradiated mice had reduced activity as early as 3 h after exposure, with recovery of activity within 24 h. The exploration activity again decreased 4 days after irradiation and the recovery occurred slowly after day 17. IL-4 ameliorated the exploration status in mice in both phases. The locomotion activity was studied using a telemetry apparatus. A similar pattern to that of the exploration data was observed, with a minimal activity observed between days 13 and 17. A radiation-induced hypothermia was also noticed over the same time period. (author)

  1. Histopathological findings in a surgically resected thalamic cavernous hemangioma 1 year after 40-Gy irradiation.

    Science.gov (United States)

    Nyáry, István; Major, Otto; Hanzély, Zoltán; Szeifert, György T

    2005-01-01

    Stereotactic radiosurgery is a controversial treatment modality in the management of cerebral cavernous hemangiomas (CHs), and results vary from center to center. Even the interpretation of treatment failure is controversial. It is suggested that the systematic pathological investigation of irradiated specimens could help to resolve the controversy. A hemorrhagic lesion in the posterior part of the thalamus had been diagnosed as a tumor and was treated with 40-Gy fractionated radiotherapy. One year after this treatment the case was reconsidered based on new imaging evidence, and the lesion was removed by conventional craniotomy. Histopathological examination revealed a CH with postirradiation changes. Compared with nonirradiated control CH tissue samples, there was endothelial cell destruction and marked fibrosis with scar tissue formation in the stroma of the treated lesion. The histopathological findings in this specimen were similar to those described in arteriovenous malformations after gamma knife surgery. The results of light microscopic investigations suggest that the ionizing effect of radiation energy evokes vascular and connective tissue stroma changes in CHs as well.

  2. Behavioural consequences of an 8 Gy total body irradiation in mice: Regulation by interleukin-4

    Energy Technology Data Exchange (ETDEWEB)

    Van der Meeren, A.; Lebaron-Jacobs, L. [Inst. de Protection et de Surete Nucleaire, Dept. de Protection de la sante de l' Homme et de Dosimetrie, Section Autonome de Radiobiologie Appliquee a la Medecine, IPSN, Fontenay-aux-Roses (France)

    2001-02-01

    The effects of an 8 Gy {gamma} total body irradiation (TBI) on exploration and locomotion activities as well as temperature were studied in C57BL6/J mice. Survival, body weight, and blood cell counts were also assessed in irradiated mice treated with placebo or interleukin (IL)-4. The efficacy of IL-4 treatment on improvement in exploration activity was evaluated. The study was carried out from 3 h to 30 days following exposure. Our results showed a biphasic response to irradiation concerning the exploration activity of mice. Irradiated mice had reduced activity as early as 3 h after exposure, with recovery of activity within 24 h. The exploration activity again decreased 4 days after irradiation and the recovery occurred slowly after day 17. IL-4 ameliorated the exploration status in mice in both phases. The locomotion activity was studied using a telemetry apparatus. A similar pattern to that of the exploration data was observed, with a minimal activity observed between days 13 and 17. A radiation-induced hypothermia was also noticed over the same time period. (author)

  3. 100 Gy 60Co γ-Ray Induced Novel Mutations in Tetraploid Wheat

    Directory of Open Access Journals (Sweden)

    Chuntao Yang

    2014-01-01

    Full Text Available 10 accessions of tetraploid wheat were radiated with 100 Gy 60Co γ-ray. The germination energy, germination rate, special characters (secondary tillering, stalk with wax powder, and dwarf, meiotic process, and high-molecular-weight glutenin subunits (HMW-GSs were observed. Different species has different radiation sensibility. With 1 seed germinated (5%, T. dicoccum (PI434999 is the most sensitive to this dose of radiation. With a seed germination rate of 35% and 40%, this dose also affected T. polonicum (As304 and T. carthlicum (As293. Two mutant dwarf plants, T. turgidum (As2255 253-10 and T. polonicum (As302 224-14, were detected. Abnormal chromosome pairings were observed in pollen mother cells of both T. dicoccoides (As835 237-9 and T. dicoccoides (As838 239-8 with HMW-GS 1Ax silent in seeds from them. Compared with the unirradiated seed of T. polonicum (As304 CK, a novel HMW-GS was detected in seed of T. polonicum (As304 230-7 and its electrophoretic mobility was between 1By8 and 1Dy12 which were the HMW-GSs of Chinese Spring. These mutant materials would be resources for wheat breeding.

  4. Histopathological findings in a surgically resected thalamic cavernous hemangioma 1 year after 40-Gy irradiation.

    Science.gov (United States)

    Nyáry, István; Major, Otto; Hanzély, Zoltán; Szeifert, György T

    2005-01-01

    ✓ Stereotactic radiosurgery is a controversial treatment modality in the management of cerebral cavernous hemangiomas (CHs), and results vary from center to center. Even the interpretation of treatment failure is controversial. It is suggested that the systematic pathological investigation of irradiated specimens could help to resolve the controversy. A hemorrhagic lesion in the posterior part of the thalamus had been diagnosed as a tumor and was treated with 40-Gy fractionated radiotherapy. One year after this treatment the case was reconsidered based on new imaging evidence, and the lesion was removed by conventional craniotomy. Histopathological examination revealed a CH with postirradiation changes. Compared with nonirradiated control CH tissue samples, there was endothelial cell destruction and marked fibrosis with scar tissue formation in the stroma of the treated lesion. The histopathological findings in this specimen were similar to those described in arteriovenous malformations after gamma knife surgery. The results of light microscopic investigations suggest that the ionizing effect of radiation energy evokes vascular and connective tissue stroma changes in CHs as well.

  5. Chapter 13. Current management situation: Great gray owls

    Science.gov (United States)

    Jon Verner

    1994-01-01

    The breeding range of great gray owls (Strix nebulosa) in the United States includes portions of Alaska, mountains in the western United States including portions of the Cascades and Sierra Nevada ranges and the northern Rockies, and portions of Minnesota, Michigan, Wisconsin, and New York (see Chapter 14 and Map 3). The species is sometimes observed...

  6. Mastering the Gray Zone: Understanding a Changing Era of Conflict

    Science.gov (United States)

    2015-12-01

    sequentially or in parallel, to a range of other tactics largely built around psychological opera- tions and information warfare. The goal is to...choice is the prisoner’s dilemma: The assumed players can see the lineup of rewards. Gray zone strategies complicate this process and raise ambiguities

  7. Anophthalmia in a Wild Eastern Gray Squirrel (Sciurus carolinensis).

    Science.gov (United States)

    Rothenburger, Jamie L; Hartnett, Elizabeth A; James, Fiona M K; Grahn, Bruce H

    2017-10-01

    We describe bilateral true anophthalmia in a juvenile female eastern gray squirrel (Sciurus carolinensis) with histologic confirmation that orbital contents lacked ocular tissues. Additionally, the optic chiasm of the brain was absent and axon density in the optic tract adjacent to the lateral geniculate nucleus was reduced.

  8. The occurrence of hepatozoon in the gray squirrel (Sciurus carolinensis)

    Science.gov (United States)

    Herman, C.M.; Price, D.L.

    1955-01-01

    Hepatozoon sciuri (Coles, 1914) is reported from gray squirrels (Sciurus carolinensis) in Washington, D.C. and Maryland. Blood smears stained with Giemsa's stain revealed a parasitemia in 16 to 71% of the squirrels examined. A technique for laking the red cells and concentrating the white cells in blood samples demonstrated this protozoon to be present in every squirrel so tested.

  9. Outplayed: Regaining Strategic Initiative in the Gray Zone

    Science.gov (United States)

    2016-06-01

    and the Great Depression . The period between 1917 and 1945 included two world wars and the Great Depres- sion. There was not a great deal of gray...2015, Center for Strategic and International Studies YouTube Channel video file, avail- able from https://www.youtube.com/watch?v=8WA1rP5WGfY

  10. Lateral cervical nucleus projections to periaqueductal gray matter in cat

    NARCIS (Netherlands)

    Mouton, LJ; Klop, EM; Broman, J; Zhang, ML; Holstege, G; Zhang, Mengliang

    2004-01-01

    The midbrain periaqueductal gray matter (PAG) integrates the basic responses necessary for survival of individuals and species. Examples are defense behaviors such as fight, flight, and freezing, but also sexual behavior, vocalization, and micturition. To control these behaviors the PAG depends on

  11. Nucleus retroambiguus projections to the periaqueductal gray in the cat

    NARCIS (Netherlands)

    Klop, EM; Mouton, LJ; Holstege, G

    2002-01-01

    The nucleus retroambiguus (NRA) of the caudal medulla is a relay nucleus by which neurons of the mesencephalic periaqueductal gray (PAG) reach motoneurons of pharynx, larynx, soft palate, intercostal and abdominal muscles, and several muscles of the hindlimbs. These PAG-NRA-motoneuronal projections

  12. Mentoring Graduate Students: The Good, Bad, and Gray

    Science.gov (United States)

    Ballantine, Jeanne H.; Jolly-Ballantine, John-Andrew

    2015-01-01

    Good mentoring of graduate students influences their perseverance and success to completion, whereas bad mentoring can result in negative outcomes, including delayed degree completion or non-completion. What the authors refer to as the gray zone is that which falls between good and bad mentoring. Examples are partial mentoring or changes in…

  13. Jim Gray on eScience: A Transformed Scientific Method

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 21; Issue 8. Jim Gray on eScience: A Transformed Scientific Method. Classics Volume 21 Issue 8 August 2016 pp 749-763. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/021/08/0749-0763. Abstract ...

  14. Dance and music share gray matter structural correlates.

    Science.gov (United States)

    Karpati, Falisha J; Giacosa, Chiara; Foster, Nicholas E V; Penhune, Virginia B; Hyde, Krista L

    2017-02-15

    Intensive practise of sensorimotor skills, such as music and dance, is associated with brain structural plasticity. While the neural correlates of music have been well-investigated, less is known about the neural correlates of dance. Additionally, the gray matter structural correlates of dance versus music training have not yet been directly compared. The objectives of the present study were to compare gray matter structure as measured by surface- and voxel-based morphometry between expert dancers, expert musicians and untrained controls, as well as to correlate gray matter structure with performance on dance- and music-related tasks. Dancers and musicians were found to have increased cortical thickness compared to controls in superior temporal regions. Gray matter structure in the superior temporal gyrus was also correlated with performance on dance imitation, rhythm synchronization and melody discrimination tasks. These results suggest that superior temporal regions are important in both dance- and music-related skills and may be affected similarly by both types of long-term intensive training. This work advances knowledge of the neural correlates of dance and music, as well as training-associated brain plasticity in general. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Gray fox (Urocyon cinereoargenteus parasite diversity in central Mexico

    Directory of Open Access Journals (Sweden)

    Norma Hernández-Camacho

    2016-08-01

    Full Text Available Mexico has a long history of parasitological studies in communities of vertebrates. However, the mega diversity of the country makes fauna inventories an ongoing priority. Presently, there is little published on the parasite fauna of gray foxes (Urocyon cinereoargenteus Schereber, 1775 and this study provides new records of parasites for gray foxes in central Mexico. It is a continuation of a series of previous parasitological studies conducted with this carnivore in Mexico from 2003 to the present. A total of 24 foxes in the Parque Nacional El Cimatario (PANEC were trapped, anaesthetized, and parasites recovered. The species found were Dirofilaria immitis, Ctenocephalides canis, C. felis, Euhoplopsillus glacialis affinis (first report for gray foxes in Mexico Pulex simulants, and Ixodes sp. Three additional gray fox carcasses were necropsied and the parasites collected were adult nematodes Physaloptera praeputialis and Toxocara canis. The intensive study of the gray fox population selected for the 2013–2015 recent period allowed for a two-fold increase in the number of parasite species recorded for this carnivore since 2003 (nine to 18 parasite species, mainly recording parasitic arthropods, Dirofilaria immitis filariae and adult nematodes. The parasite species recorded are generalists that can survive in anthropic environments; which is characteristic of the present ecological scenario in central Mexico. The close proximity of the PANEC to the city of Santiago de Queretaro suggests possible parasite transmission between the foxes and domestic and feral dogs. Furthermore, packs of feral dogs in the PANEC might have altered habitat use by foxes, with possible impacts on transmission.

  16. "Mr. Database" : Jim Gray and the History of Database Technologies.

    Science.gov (United States)

    Hanwahr, Nils C

    2017-12-01

    Although the widespread use of the term "Big Data" is comparatively recent, it invokes a phenomenon in the developments of database technology with distinct historical contexts. The database engineer Jim Gray, known as "Mr. Database" in Silicon Valley before his disappearance at sea in 2007, was involved in many of the crucial developments since the 1970s that constitute the foundation of exceedingly large and distributed databases. Jim Gray was involved in the development of relational database systems based on the concepts of Edgar F. Codd at IBM in the 1970s before he went on to develop principles of Transaction Processing that enable the parallel and highly distributed performance of databases today. He was also involved in creating forums for discourse between academia and industry, which influenced industry performance standards as well as database research agendas. As a co-founder of the San Francisco branch of Microsoft Research, Gray increasingly turned toward scientific applications of database technologies, e. g. leading the TerraServer project, an online database of satellite images. Inspired by Vannevar Bush's idea of the memex, Gray laid out his vision of a Personal Memex as well as a World Memex, eventually postulating a new era of data-based scientific discovery termed "Fourth Paradigm Science". This article gives an overview of Gray's contributions to the development of database technology as well as his research agendas and shows that central notions of Big Data have been occupying database engineers for much longer than the actual term has been in use.

  17. Histological studies in developing brain after 0.5 Gy neutron irradiation in utero

    International Nuclear Information System (INIS)

    Antal, S.; Fueloep, Z.

    1986-01-01

    Pregnant mice were irradiated with 0.5 Gy neutrons on day 13, 15 or 18 of gestation. There was no significant difference in number of living young born per litter between in neutron irradiated mice and controls. Mortality of irradiated offspings increased in the first 3 days after birth. The brain weight of 21-day old animals after neutron irradiation averaged only 55, 56 and 69% of controls, resp. At six hours after irradiation morphological analysis showed nuclear pyknosis in the central nervous system. On day 13 the telencephalon was severely affected. The 30% cells were pyknotic in the wall of the cerebral hemisphere and 20% of cells in corpus striatum. In the metencephalon marked pyknosis was established in the tectal lamina of mesencephalon (16%) and in the cerebellar anlage (21%). The olfactory plate (24%), the ventricular zone of cerebral hemisphere (30%) and colliculus ganglionaris were damaged mostly (40%) after radiation on day 15 of gestation. The tectum of the mesencephali and in metencephalon the external granular layer of cerebellum and area of the rhombic lip were affected by irradiation (17-20%). The telencephalon found pyknotic but to a less extent in group irradiated on day 18 than it was on day 15. In the olfactory bulb 10% of pyknotic cells were seen and 16% of primary cortex of cerebral hemisphere more over 30% of nucleus caudatus/putamen were affected. In metencephalon 19% of external granular layer of cerebellum and 13% of trigonum cerebelli were pyknotic. In general, lesions of irradiation were rather mild in diencephalon and myelencephalon at all examined ages. Histological examinations support that defined parts of brain are damaged after neutron irradiation in utero and it may lead to the described physiological 18-20 and biochemical consequences 20,23 . (orig.)

  18. 76 FR 12070 - Availability of Seats for the Gray's Reef National Marine Sanctuary Advisory Council

    Science.gov (United States)

    2011-03-04

    ... the Gray's Reef National Marine Sanctuary Advisory Council AGENCY: Office of National Marine Sanctuaries (ONMS), National Ocean Service (NOS), National Oceanic and Atmospheric Administration (NOAA... applications for the following vacant seat on the Gray's Reef National Marine Sanctuary Advisory Council...

  19. 76 FR 68428 - Availability of Seats for the Gray's Reef National Marine Sanctuary Advisory Council

    Science.gov (United States)

    2011-11-04

    ... the Gray's Reef National Marine Sanctuary Advisory Council AGENCY: Office of National Marine Sanctuaries (ONMS), National Ocean Service (NOS), National Oceanic and Atmospheric Administration (NOAA... applications for the following vacant seats on the Gray's Reef National Marine Sanctuary Advisory Council...

  20. 77 FR 27719 - Availability of Seats for the Gray's Reef National Marine Sanctuary Advisory Council

    Science.gov (United States)

    2012-05-11

    ... the Gray's Reef National Marine Sanctuary Advisory Council AGENCY: Office of National Marine Sanctuaries (ONMS), National Ocean Service (NOS), National Oceanic and Atmospheric Administration (NOAA... applications for the following vacant seats on the Gray's Reef National Marine Sanctuary Advisory Council...

  1. 75 FR 17899 - Availability of Seats for the Gray's Reef National Marine Sanctuary Advisory Council

    Science.gov (United States)

    2010-04-08

    ... the Gray's Reef National Marine Sanctuary Advisory Council AGENCY: Office of National Marine Sanctuaries (ONMS), National Ocean Service (NOS), National Oceanic and Atmospheric Administration (NOAA... applications for the following vacant seats on the Gray's Reef National Marine Sanctuary Advisory Council...

  2. 76 FR 27307 - Availability of Seats for the Gray's Reef National Marine Sanctuary Advisory Council

    Science.gov (United States)

    2011-05-11

    ... the Gray's Reef National Marine Sanctuary Advisory Council AGENCY: Office of National Marine Sanctuaries (ONMS), National Ocean Service (NOS), National Oceanic and Atmospheric Administration (NOAA... applications for the following vacant seat on the Gray's Reef National Marine Sanctuary Advisory Council...

  3. Prevention of heterotopic bone formation with early post operative irradiation in high risk patients undergoing total hip arthroplasty: comparison of 10.00 Gy vs 20.00 Gy schedules

    International Nuclear Information System (INIS)

    Anthony, P.; Keys, H.; Evarts, C.M.; Rubin, P.; Lush, C.

    1987-01-01

    Prior studies have demonstrated the effectiveness of postoperative radiation therapy (RT) to the hip area following total hip replacement (THR) surgery in preventing the development of heterotopic bone formation in patients considered to be at high risk for development of this complication. Previously, patients received 20.00 Gy in 10 fractions (fx) over 2 weeks, beginning as soon postop as medically feasible (usually post-op day 2). In an effort to reduce hospital stay and risk of secondary malignancy, a prospective treatment program was initiated April 1982 using a reduced dose of 10.00 Gy in 5 fx over 5-7 days. As of February 1984, 46 consecutive hips determined to be at high risk were treated with this reduced dose. Prior studies have demonstrated that heterotopic bone is always radiographically evident by 8 weeks. Of the 46 hips, 41 had been evaluated with the minimum required 8 week follow-up X ray. Twenty-five of these hips, 61%, had a mean long term follow-up of 12 months. It historical control group, consisting of 54 consecutive high risk post-THR's, was shown to have a 68.5% incidence of heterotopic bone. The 20.00 Gy group, when RT was started by post-op day 5, demonstrated a 3.2% incidence, compared to 4.9% in the 10.00 Gy group. Complication rates were also comparable in the two RT groups, 19.4% and 7.3% respectively; 10.00 Gy is apparently as effective as 20.00 Gy in preventing heterotopic bone formation in high risk post-THR patients

  4. Chapter 16. Conservation status of great gray owls in the United States

    Science.gov (United States)

    Gregory D. Hayward

    1994-01-01

    Previous chapters outlined the biology and ecology of great gray owls as well as the ecology of this species in the western United States. That technical review provides the basis to assess the current conservation status of great gray owls in the United States. Are populations of great gray owls in the United States currently threatened? Are current land management...

  5. 76 FR 78240 - Gray Portland Cement and Clinker From Japan: Continuation of Antidumping Duty Order

    Science.gov (United States)

    2011-12-16

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-588-815] Gray Portland Cement and... Department) initiated the third sunset review of the antidumping duty order on gray portland cement and... of the antidumping duty order on gray portland cement and clinker from Japan would likely lead to...

  6. Atrophy of gray and white matters in the brain during aging

    International Nuclear Information System (INIS)

    Takeda, Shumpei; Matsuzawa, Taiju; Ito, Hisao.

    1984-01-01

    We studied atrophy of gray and white matter during aging in 57 males and 44 females with no neurological disturbances using x-ray computed tomography. The ages ranged from 12 to 80 years. Brain atrophy was expressed as brain volume index: 100% x [(brain volume/cranial cavity volume) in individual subjects]/[(brain volume/cranial cavity volume) in normal subjects of 20-39 years]. Atrophy of gray and white matter volume was expressed as gray and white matter volume indices: 100% x (apparent gray or white matter volume index in individual subjects)/(apparent gray or white matter volume index in normal subjects whose brain volume index was greater than 98%), where apparent gray and white matter volume indices were expressed as 100% x [(gray or white matter volume/cranial cavity volume) in individual subjects]/[(gray or white matter volume/cranial cavity volume) in normal subjects of 20-39 years]. Both the gray and white matter volume indices changed proportionally to the brain volume index (p<0.001). As the brain atrophy advanced, the gray matter volume index decreased more than the white matter volume index (P<0.001). Decrease in the gray and white matter volume indices was statistically significant only in seventies (P<0.002 for gray matter, P<0.05 for white matter). (author)

  7. 75 FR 68756 - Eastern North Pacific Gray Whale; Notice of Petition Availability

    Science.gov (United States)

    2010-11-09

    ... North Pacific Gray Whale; Notice of Petition Availability AGENCY: National Marine Fisheries Service... petition to designate the Eastern North Pacific population of gray whales (Eschrichtius robustus) as a... Eastern North Pacific gray whales is available on the Internet at the following address: http://www.nmfs...

  8. MASTICATORY MUSCLE MYOSITIS IN A GRAY WOLF (CANIS LUPUS).

    Science.gov (United States)

    Kent, Marc; Glass, Eric N; Castro, Fernando A; Miller, Andrew D; de Lahunta, Alexander

    2017-03-01

    A 10-yr-old male, neutered gray wolf ( Canis lupus ) was presented for atrophy of the temporalis and masseter muscles. Clinical signs and magnetic resonance imaging were consistent with a myopathy. Positive serology for antibody titers directed against Type 2M myofibers, and the observation of a mixed mononuclear inflammatory cell infiltrate along with eosinophils and neutrophils within the temporalis muscle, were diagnostic for masticatory muscle myositis. Importantly, protozoal myositis was excluded based on other clinicopathologic data. The case highlights the potential for immune-mediated polymyositis in canids other than the domesticated dog ( Canis lupus familaris). Additionally, awareness of a diet in which raw meat is used should prompt a thorough investigation for an underlying infectious myositis in the gray wolf.

  9. CASTRO: A NEW COMPRESSIBLE ASTROPHYSICAL SOLVER. II. GRAY RADIATION HYDRODYNAMICS

    International Nuclear Information System (INIS)

    Zhang, W.; Almgren, A.; Bell, J.; Howell, L.; Burrows, A.

    2011-01-01

    We describe the development of a flux-limited gray radiation solver for the compressible astrophysics code, CASTRO. CASTRO uses an Eulerian grid with block-structured adaptive mesh refinement based on a nested hierarchy of logically rectangular variable-sized grids with simultaneous refinement in both space and time. The gray radiation solver is based on a mixed-frame formulation of radiation hydrodynamics. In our approach, the system is split into two parts, one part that couples the radiation and fluid in a hyperbolic subsystem, and another parabolic part that evolves radiation diffusion and source-sink terms. The hyperbolic subsystem is solved explicitly with a high-order Godunov scheme, whereas the parabolic part is solved implicitly with a first-order backward Euler method.

  10. Phase 2 Trial of Accelerated, Hypofractionated Whole-Breast Irradiation of 39 Gy in 13 Fractions Followed by a Tumor Bed Boost Sequentially Delivering 9 Gy in 3 Fractions in Early-Stage Breast Cancer

    International Nuclear Information System (INIS)

    Kim, Ja Young; Jung, So-Youn; Lee, Seeyoun; Kang, Han-Sung; Lee, Eun Sook; Park, In Hae; Lee, Keun Seok; Ro, Jungsil; Lee, Nam Kwon; Shin, Kyung Hwan

    2013-01-01

    Purpose: To report a phase 2 trial of accelerated, hypofractionated whole-breast irradiation (AH-WBI) delivered as a daily dose of 3 Gy to the whole breast followed by a tumor bed boost. Methods and Materials: Two hundred seventy-six patients diagnosed with breast cancer (pT1-2 and pN0-1a) who had undergone breast-conserving surgery in which the operative margins were negative were treated with AH-WBI delivered as 39 Gy in 13 fractions of 3 Gy to the whole breast once daily over 5 consecutive working days, and 9 Gy in 3 sequential fractions of 3 Gy to a lumpectomy cavity, all within 3.2 weeks. Results: After a median follow-up period of 57 months (range: 27-75 months), the rate of 5-year locoregional recurrence was 1.4% (n=4), whereas that of disease-free survival was 97.4%. No grade 3 skin toxicity was reported during the follow-up period. Qualitative physician cosmetic assessments of good or excellent were noted in 82% of the patients at 2 months after the completion of AH-WBI. The global cosmetic outcome did not worsen over time, and a good or excellent cosmetic outcome was reported in 82% of the patients at 3 years. The mean pretreatment percentage breast retraction assessment was 12.00 (95% confidence interval [CI]: 11.14-12.86). The mean value of percentage breast retraction assessment increased to 13.99 (95% CI: 12.17-15.96) after 1 year and decreased to 13.54 (95% CI: 11.84-15.46) after 3 years but was not significant (P>.05). Conclusions: AH-WBI consisting of 39 Gy in 13 fractions followed by a tumor bed boost sequentially delivering 9 Gy in 3 fractions can be delivered with excellent disease control and tolerable skin toxicity in patients with early-stage breast cancer after breast-conserving surgery

  11. Design of inspection equipment vehicle of mobile cobalt-60 container scanner

    International Nuclear Information System (INIS)

    Zhang Yanmin; An Jigang; Zhou Liye; Liu Yisi; Wu Zhifang; Xiang Xincheng; Huang Songling

    2000-01-01

    The author introduced the design principle of Inspection Equipment Vehicle of TCM-SCAN Mobile 60 Co container inspection system. Three schemes had been compared. The scheme of scan gate in form of pucker-able rails standing on the vehicle was determined. Prototype was prepared in September 1999. Mobile 60 Co container inspection system had the same inspection performance of fixed 60 Co container inspection system

  12. Electronic equilibrium as a function of depth in tissue from cobalt-60 point source exposures

    International Nuclear Information System (INIS)

    Myrick, J.A.

    1994-08-01

    The Nuclear Regulatory Commission has set the basic criteria for assessing skin dose stemming from hot particle contaminations. Compliance with 10 CFR 20.101 requires that exposure to the skin be evaluated over a 1 cm 2 area at a depth of 0.007 cm. Skin exposure can arise from both the beta and gamma components of radioactive particles and gamma radiation can contribute significantly to skin doses. The gamma component of dose increases dramatically when layers of protective clothing are interposed between the hot particle source and the skin, and in cases where the hot particle is large in comparison to the range of beta particles. Once the protective clothing layer is thicker than the maximum range of the beta particles, skin dose is due solely to gamma radiation. Charged particle equilibrium is not established at shallow depths. The degree of electronic equilibrium establishment must be assessed for shallow doses to prevent the over-assessment of skin dose because conventional fluence-to-dose conversion factors are not applicable. To assess the effect of electronic equilibrium, selected thicknesses of tissue equivalent material were interposed between radiochromic dye film and a 60 Co hot particle source and dose was measured as a function of depth. These measured values were then compared to models which are used to calculate charged particle equilibrium. The Miller-Reece model was found to agree closely with the experimental data while the Lantz-Lambert model overestimated dose at shallow depths

  13. Principles of cobalt-60 teletherapy including an introduction to the compendium. Definitions and conventions

    International Nuclear Information System (INIS)

    Cohen, M.; Mitchell, J.S.

    1984-01-01

    The convention used in the display of the transverse sections of the human body in the plans for radiotherapy follows the editorial policy of the Journal of Computer Assisted Tomography. For the purpose of this Compendium the convention is defined as: The ''seen from above'' convention is used for the head and upper neck, in which is included the oropharynx. This is the 'anatomical convention' now used with the computed tomography (CT) head scanner and is accepted generally by neuroradiologists, neurosurgeons and neurologists. This convention is also employed in the display of isotope scans of the head. The ''seen from below'' convention is used for the rest of the body, i.e. below the level of the lower border of the third cervical vertebral body; this includes the hypopharynx, larynx and thyroid. This is the usual 'radiological convention', i.e. the patient's right is on the observer's left. This is the convention generally used in total body CT scanning of the thorax and abdomen; the same convention is used in isotope and ultrasonic imaging

  14. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of 60 Co give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of 60 Co has created an insurance quality system which insures the maximum of security for the user. (orig.) [de

  15. Principles of cobalt-60 teletherapy including an introduction to the compendium. Guidelines in clinical radiation oncology

    International Nuclear Information System (INIS)

    Mitchell, J.S.; Hlasivec, Z.

    1984-01-01

    It is generally accepted that the clinical radiotherapeutic oncologist must be a well educated doctor, with wide knowledge and experience, able to deal with the many difficult problems that can arise in connection with radiotherapy, curative, palliative or prophylactic. The management, treatment and care of the individual patient with malignant disease is a major task of medicine, requiring up-to-date knowledge in a number of rapidly advancing fields. To be efficient, it is essential for the clinical radiation oncologist to continue his education throughout his life, by reading the literature, attending lectures, conferences and advanced 'refresher' courses, and by visiting other centres. The clinical radiation oncologist will discover that it is wise, where at all possible, to spend a proportion of his time working with other specialists on clinical trials and research, with formal publication of the results. The disciplines of such work will deepen his understanding, not only of his own speciality, but of the whole field of oncology, and will further co-operation between the many different specialists on whose combined efforts the cure of each individual patient and the advances in the treatment of cancer must ultimately depend

  16. Transportation of Radioactive Material Cobalt-60 is one of the Experience

    International Nuclear Information System (INIS)

    Mohd Derus Ibrahim

    2015-01-01

    During transportation of radioactive material in progress, all the procedure (SOP) must have been followed by legally and the wrappers that have been used must be not contaminated, it ensure that safety and security during transportation. (author)

  17. Migration characteristics of cobalt-60 through sandy soil in high pH solution

    International Nuclear Information System (INIS)

    Ohnuki, Toshihiko

    1992-01-01

    Migration characteristics of 60 Co through sandy soil in high pH solution has been investigated by both column and batch techniques. The association of 60 Co with the sandy soil and its components were studied by sequential extraction techniques. The concentration profile of 60 Co in the sandy soil column was composed of two exponential curves showing that 60 Co would consist of immobile and mobile fractions. The immobile 60 Co was retained by the sandy soil and was distributed near the top. Though the mobile 60 Co was little sorbed by soil and migrated through the soil column, maximum concentration of 60 Co in the effluents decreased slightly with increasing path length of the soil column. The sequential extraction of 60 Co from the sandy soil and from its components showed that 60 Co was sorbed by both manganese oxide and clay minerals. And manganese oxide is one of the responsible soil components for the observed decrease in the maximum concentration of 60 Co in the effluents. Although the content of manganese oxide in the sandy soil was 0.13%, manganese oxide is the important component to prevent from the migration of 60 Co in the high pH solution. (author)

  18. Preliminary feasibility study on production of cobalt-60 source for industrial irradiation

    International Nuclear Information System (INIS)

    Joo, Po Kook; Park, Kyung Bae; Ahn, Yun Soo; Lee, Jong Tai; Kim, Hark Rho

    1999-05-01

    As there is a high possible demand of industrial Co-60 source in the world market, feasibility study of a project was performed to produce and to export Co-60 sources, utilizing KEPCO's Wolsung NPP for irradiation of cobalt and KAERI's hot-cells for fabrication of cobalt sources. Main concerns of the study were to understand irradiation and fabrication (encapsulation) processes and to examine related technologies, required facilities and equipment. In particular, it was examined intensively if it would be possible to modify facilities around the reactor vessel of Wolsung NPP tp substantiate the related licensing in order to irradiate cobalt in the reactor. It is expected that once, if cooperation scheme with MDS Nordion of Canada is established, main issues such as modification of facilities, related licensing, raw material procurement and technology transfer for high quality product will be solved. In order to review overall feasibility of the project, present status and prospect of the world market was surveyed and various usages of cobalt sources were reviewed with emphasis on possible demand increase per usage. Food poisoning accidents are prevailing worldwide and food irradiation with cobalt sources is considered as a promising measure to prevent them and may bring forth high increase of cobalt sources demand in the world market. Preliminary economic feasibility was studied in conservation, evaluating roughly the investment and the operating cost based on materials from various information sources. (author)

  19. Effect of cobalt 60 gamma-ray irradiation on the hatching process of chicken eggs

    International Nuclear Information System (INIS)

    Ohkuma, Yoshikazu

    1981-01-01

    An experiment on fertilized chicken eggs was carried out to determine the effects of 60 Co irradiation on the embryos, their fatality, and growth impairment or deformity, in particular. The experimental groups, consisting of 10 eggs each, recieved a 60 Co irradiation of 50 to 2,000 rads on any one day between day 0 and day 20 of incubation. The larger the irradiation dose, the greater was the number of dead embryos. The fatality was higher in the groups receiving irradiation in the earlier stage (1st week). The resultant death was a chronic one. The irradiation also caused body weight decrease and growth impairment. A decrease in the brain and liver weights was noted, suggesting insufficiency in these organs. Deformity occurred in 4%, most of which involved impairments of skeletal growth, of the bones of the extremities and the bill, in particular. Administration of the SH amino acid, cysteine tended to alleviate the adverse effects of the 60 Co irradiation. These results for fertilized chicken eggs suggest the possibility of abortion and the occurrence of deformities in human fetuses if they should be subjected to 60 Co irradiation. (author)

  20. Recent status on cobalt-60 gamma ray radiation sources production and its application in China

    International Nuclear Information System (INIS)

    Cao Zhijian; Song Yunjiang; Zhang Chunhua; Li Maoling

    1993-01-01

    This paper describes the status of Co-60 γ ray radiation sources and their application in China. At present, the production capacity of Co-60 γ ray radiation sources in China is about 11.1 PBq (0.3 MCi) per year. 5 years later, it is increased to 37 PBq (1 MCi) per year. The radioactivity of each source is 370 TBq - 740 TBq (1000-2000 Ci). There are over 150 Co-60 γ ray radiation facilities with total design capacity of over 370 PBq (10 MCi) and practical capacity of about 92.5 PBq (2.5 MCi) in operation. The number of Co-60 γ ray radiation facilities with practical capacity of over 3.7 PBq (0.1 MCi) is 14. The main applications of the Co-60 γ ray sources are radiation crosslinking, radiation sterilization of disposable medical supplies and food irradiation. The prospects for Co-60 γ ray radiation source application in China are good. (author)

  1. An evaluation of low-energy x-ray and cobalt-60 irradiations of MOS transistors

    International Nuclear Information System (INIS)

    Dozier, C.M.; Fleetwood, D.M.

    1987-01-01

    An evaluation of methodologies for irradiating MOS transistors with low-energy x-ray and Co-60 sources has been performed. The authors find that comparisons of voltage shifts produced by bulk trapped charge and interface states in MOS transistors irradiated using two different low energy x-ray sources (an ARACOR 10 keV W source and an 8 keV Cu source) agree to within better than 30 percent. This quality of agreement is similar in magnitude to that between MOS devices irradiated by different Co-60 sources. In contrast, the measurements indicate that interlaboratory comparisons of ratios of shifts produced by x-ray and Co-60 sources can lead to differences in ratios as large as a factor of --1.7. Improved electron-hole recombination data for oxides is presented. This recombination correction, in conjunction with a correction for interface dose enhancement, is used to predict the ratios of shifts produced by x-ray and Co-60 sources. However, the results show that corrections for electron-hole recombination and interface does enhancement do not, by themselves, adequately predict the field dependent behavior of these transistors

  2. SU-E-T-623: Polarity Effects for Small Volume Ionization Chambers in Cobalt-60 Beams

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Y; Bhatnagar, J; Huq, M Saiful [Department of Radiation Oncology, University of Pittsburgh Cancer Institute and UPMC Cancer Center, Pittsburgh, PA (United States)

    2015-06-15

    Purpose: To investigate the polarity effects for small volume ionization chambers in {sup 60}Co gamma-ray beams using the Leksell Gamma Knife Perfexion. Methods: Measurements were made for 7 small volume ionization chambers (a PTW 31016, an Exradin A14, 2 Capintec PR0-5P, and 3 Exradin A16) using a PTW UNIDOSwebline Universal Dosemeter and an ELEKTA solid water phantom with proper inserts. For each ion chamber, the temperature/pressure corrected electric charge readings were obtained for 16 voltage values (±50V, ±100V, ±200V, ±300V, ±400V, ±500V, ±600V, ±700V). For each voltage, a five-minute leakage charge reading and a series of 2-minute readings were continuously taken during irradiation until 5 stable signals (less than 0.05% variation) were obtained. The average of the 5 reading was then used for the calculation of the polarity corrections at the voltage and for generating the saturation curves. Results: The polarity effects are more pronounced at high or low voltages than at the medium voltages for all chambers studied. The voltage dependence of the 3 Exradin A16 chambers is similar in shape. The polarity corrections for the Exradin A16 chambers changes rapidly from about 1 at 500V to about 0.98 at 700V. The polarity corrections for the 7 ion chambers at 300V are in the range from 0.9925 (for the PTW31016) to 1.0035 (for an Exradin A16). Conclusion: The polarity corrections for certain micro-chambers are large even at normal operating voltage.

  3. Quality and security on the uses of cobalt 60 sources for industrial irradiators

    International Nuclear Information System (INIS)

    Desroches, J.

    1976-01-01

    The construction and operation of industrial irradiators using large quantities of 60 Co give rise to an important problem of security. The CEA Radioisotope Department which manufactures and sells sources of 60 Co has created an insurance Quality System which insures the maximum of security for the user

  4. The split-sting trait in Apis mellifera induced by cobalt 60 gamma radiation

    International Nuclear Information System (INIS)

    Silva, Vera Lucia Maciel

    1993-01-01

    The Split-Sting (SS) trait in honey bees, induced by gamma radiation, was discovered by Soares (1975). Bees with this trait are unable to sting, because the parts that compose the sting are separated. Many studies have been done in order to understand this new mutation. We studied the effect of gamma radiation on induction of the SS trait in feral bee strains. The doses were applied to the phase of larvae of queens with 5 days old. The following results were obtained: all doses of radiation induced the SS trait. There was an increase in the percentage of queens with SS with an increase in radiation dose; the SS trait induced by radiation is probably phenocopy; SS bees were observed in nature; increase of the rate mortality and malformation with an increase in radiation dose. (author)

  5. Transfer of Cobalt-60 to plants from soils treated with sewage sludge

    International Nuclear Information System (INIS)

    Grummitt, W.E.

    1976-01-01

    The uptake of 60 Co from soils fertilized with contaminated sewage sludge has been investigated under a variety of experimental conditions. A number of garden plots were prepared by thoroughly mixing sludge containing 60 Co with farm soils from the Ottawa Valley. Edible plants were grown in the open on these plots under conditions approximating those in market gardens. The crops were harvested at maturity and were prepared for measurement of 60 Co by drying portions of the roots, leaves, stems and fruit. The samples were counted on a large germanium detector which was capable of resolving 60 Co from other gamma-emitting nuclides. Cobalt was readily taken up from contaminated sludge but was nonuniformly distributed in various parts of the plant. In general, the roots showed the highest levels while edible portions such as seeds and tubers had much lower concentrations. The uptake ratio, expressed as radioactivity in the sample to radioactivity in the soil, varied from 0.003 to 8 on a dry-weight basis. (author)

  6. Depth determination of buried caesium-137 and cobalt-60 sources using scatter peak data

    International Nuclear Information System (INIS)

    Adams, J. C.; Joyce, M. J.; Mellor, M.

    2009-01-01

    An investigation into an alternative approach to 3D (3-dimensional) source mapping is proposed, by combining the insights of two existing techniques. The first of these is a 3D 'imaging' tool, N-Visage TM that has been developed by REACT Engineering Ltd. This technique is efficient and robust, but is not a true 3D technique as it relies on user-supplied 2D (2-dimensional) manifolds to constrain source locations. The second technique uses the γ-photopeak and an X-ray peak to determine radionuclide source depth using a relative attenuation method. We look at the possibility of combining both techniques to constrain both the location and depth of a radiological source buried under shielding. It is believed a combined method using spectra recorded above the shielding object will be of use in the nuclear decommissioning and land contamination industries. N-Visage TM has previously been used to map source distributions of mixed radionuclides with complex geometries through shielding media. The software works by producing a computer model which recreates the experimental setup. A survey is imported, comprising a set of γ-spectra recorded with an instrument of known efficiency and isotropy taken at a variety of locations around the area of interest. A survey plan recording the location and orientation of the instrument for each reading is also reconstructed. N-Visage TM is then able to determine the locations of the source(s) without prior knowledge of exactly where they are located, by building and inverting a simple physical model relating potential source locations to the recorded spectra. This research sets out to investigate the possibility of combining the geometric insights of N-Visage TM with a method of extracting depth information from scatter data, rather than the X-ray peak. By combining the γ-photopeak and scatter areas of a spectrum, the thickness of the shielding media between source and detector can potentially be inferred. Using scattered photons rather than X-ray attenuation is preferable where depths are of a sufficient thickness to effectively eliminate a measurable X-ray photopeak. (authors)

  7. Accounting for the self-absorption of betas in cobalt-60 hot particles

    International Nuclear Information System (INIS)

    Lantz, M.W.; Steward, J.B.

    1988-01-01

    This paper reports that the assumptions used dose calculations can be overly conservative for discrete hot particles (activated satellite chips and irradiated fuel fragments) due to self-absorption of betas within the particles. Using data from tests with a Co-60 hot particle, a model is developed to estimate the dose reduction factor afforded by self-absorption in a satellite chip with a known thickness. The model can be applied indirectly using ion chamber survey instrument readings (the thickness of the particle does not have to be measured). Tests with Co-60 particles found at the Palo Verde Nuclear Generating Station verify that self-absorption is significant -- in one case, a dose reduction factor of 7 was measured in a satellite chip with a visible thickness

  8. New data on the self-absorption of betas in cobalt-60 hot particles

    International Nuclear Information System (INIS)

    Lantz, M.W.; Steward, J.B.

    1988-01-01

    The authors demonstrated that standard dose calculation methods for hot particles could seriously overestimate the beta dose rate component to skin. The reason-self-absorption within an activated satellite particle that has a finite thickness can lead to dramatic reductions in beta output, as compared to that predicted by calculation models that assume the particle has zero thickness. In this paper, the authors demonstrate the self-absorption effect with a particle model and confirmed it with measurements on two high-activity Co-60 particles found at the Palo Verde Nuclear Power Station. The authors then described a method for using an Eberline RO-2 ion chamber survey instrument to estimate the beta dose rate reduction related to self-absorption within a particle. This method relied on the comparison of the uncorrected beta/gamma ratio [(open window-closed window) divided-by closed window] for a particle expected of exhibiting self-absorption to the ratio obtained for a particle of zero thickness

  9. Repacking of Cobalt 60 spent sources in the central interim storage

    International Nuclear Information System (INIS)

    Zeleznik, N.

    2003-01-01

    After the transfer of the responsibility for the management of the Central interim storage for waste from small producers, located at the reactor centre in Brinje near Ljubljana, Slovenia, the national Agency for radwaste management (ARAO) started with most urgent activities to improve the utilization of the storage facility. One of the main tasks has also been the rearrangement of the already stored radioactive waste in order to reduce volume of the waste and to collect same radioisotopes in the containers. The latest campaign, performed in 2002/2003, was repacking of all Co-60 spent sealed sources in the storage facility and also at the producer's premises which were after conditioning put into two drums with concrete matrix and stored back to the Central interim storage. The preparation works together with the implementation are described in the paper. (author)

  10. Cobalt-60 total body irradiation dosimetry at 220 cm source-axis distance

    International Nuclear Information System (INIS)

    Glasgow, G.P.; Mill, W.B.

    1980-01-01

    Adults with acute leukemia are treated with cyclophosphamide and total body irradiation (TBI) followed by autologous marrow transplants. For TBI, patients seated in a stand angled 45 0 above the floor are treated for about 2 hours at 220 cm source-axis distance (SAD) with sequential right and left lateral 87 cm x 87 cm fields to a 900 rad mid-pelvic dose at about 8 rad/min using a 5000 Ci cobalt unit. Maximum (lateral) to minimum (mid-plane) dose ratios are: hips--1.15, shoulders--1.30, and head--1.05, which is shielded by a compensator filter. Organ doses are small intestine, liver and kidneys--1100 rad, lung--1100 to 1200 rad, and heart--1300 rad. Verification dosimetry reveals the prescribed dose is delivered to within +-5%. Details of the dosimetry of this treatment are presented

  11. Skin response to cobalt 60 irradiation and the consequences for matching the color of facial prostheses

    International Nuclear Information System (INIS)

    van Oort, R.P.; Vermey, J.; Ten Bosch, J.J.

    1984-01-01

    A radiotherapy treatment ( 60 Co) of cancer in the head and neck region causes side effects in the skin that postpone the facial prosthetic treatment. The increasing and fading erythema and pigmentation of the skin was investigated with the use of a subtractive colorimeter. This method was verified with photographs scored according to the Oxford scoring system. Fourteen patients were investigated during a period of 24 weeks. The mean colorimetric skin response showed a peak 6 weeks after the onset of irradiation. Six to 7 weeks later, there was no significant difference between the skin color before and after irradiation. At this time the dry desquamation of the skin is healed. From this viewpoint, the color matching procedure for a facial prosthesis may start not earlier than 15 weeks from the onset of irradiation. If a nonirradiated control field in the facial region is present, a color match for the facial prosthesis can be started just after the irradiation period

  12. Quality control in food irradiated with gamma radiations from Cobalt 60

    International Nuclear Information System (INIS)

    Bustos R, M.E.

    1993-01-01

    The quality control of irradiated food can only be carry out in the irradiation plant by means of the measurement of the absorbed dose by the product, since to day there is not exist a technique which allows to demonstrate that a food has been irradiated. Dosemeters are materials or devices which measure the absorbed dose by the product during the irradiation time. The type of the dosemeter is a choice as a function of factors as the range of dose for to reach of the desired technical purpose, the cost, the handling facility (handy) and its availability. The correct measurements of dose and dose distribution permits to indicate that the irradiation process is safe, effective and legally correct. The food quality after the irradiation is analyzed on basis and tests already established for a specific product: such tests can be sensory, chemical, physical or physiological> The quality control of the irradiation food is an important information for the consumer who wishes to know the food value and hygienic properties of the product. (Author)

  13. Sterilization by cobalt 60 of the mediterranean fruit fly Ceratitis Capitate Wied

    International Nuclear Information System (INIS)

    Dimundu Puena, I.; Cirio, Ugo.

    1978-01-01

    Ceratitis capitata have been irradiated with 2, 4, 6 and 10 Krad of a Co-60 gamma irradiator at 300 rad/min flow. Following results have been obtained: abundant and regular egg laid at 1 to 2 krads, reduced but regular egg laid at 4 krads and total sterility from 6 krads. The 10 krads irradiated insects exhibit satisfactory life time and activity. The 6 and above krads irradiated females are completely sterile but have the laid reflex. The 8 krads irradiated males exhibit sexual strength comparable to that of normal males. Males fertility is decreased with increasing irradiation dose, eggs obtained with normal female have fertility of less than 1 % for doses above 7 krads. However it appears that at 8 krads dose, some males can form again normal spermatozoids after 20 to 30 days. The recommended irradiation dose is 10 krads

  14. Sedimentation of Cobalt-60 and Cesium-137 in the bay of Tvaeren 1964-1980

    International Nuclear Information System (INIS)

    Ramberg, L.; Lampe, S.

    1980-11-01

    Since 1964 the Co-60 and Cs-137 radioactivity of the sediments of the Tvaeren bay has been recorded every year at several points. Changes have been analysed in relation to atmospheric fallout releases from Studsvik distance from release point and depth. Estimates of total quantity for both nuclides bound up in the sediments and a forecast of future trends are presented. Sedimentation coefficients have been calculated and the factors which govern the degree of sedimentation are discussed.(G.B.)

  15. Introduction dosimetric data of cobalt-60 unit in planning new Win-PTL- 3D

    International Nuclear Information System (INIS)

    Gonzalez Perez, Yelina; Rodriguez Zayas, Michael; Perez Guevara, Adrian; Sanchez Zamora, Luis; Reyes Gonzalez, Tommy; Sola Rodriguez, Yeline; Caballero, Roberto; Cruz Marcane, Viviana

    2009-01-01

    3D planning is based on the individual and image reconstruction formation of fields, allowing better absorption of dose volume White minimizing damage to surrounding healthy tissue. During the clinical implementation of the Win-PLT software includes validation from the implementation of dosimetric acceptance tests through a series of precise experimental measurements, reflecting different clinical situations (test cases). For the commissioning characterized the photon beam Cobalt Unit 60, taking measurements with a set consisting of a phantom dosimetric automatic ionization chambers and electrometer Tandem. The measured data are used to power the TPS through WINCOM auxiliary program that lets you adjust a number of parameters to model the photon beam. This adjustment is made by comparing the PDD curves and profiles of experimental data with modeled data. The test cases performed are in compliance with the requirements proposed in the geometric of the AAPM TG55. The modeling of beam dosimetry data was successful, since the discrepancies were within the criteria TRS-430. The cases involved events where points near the edge of the field and in the presence of blocking a discrepancy outside the tolerance, suggesting not to use these items for purposes of limitation. Win TPS-PLT is suitable for clinical use with the photon beam Cobalt Unit 60, backed by the reliability that dropped on the results of beam modeling and verification of dosimetric calculations. (Author)

  16. Effect on treatment planning based on properties of Cobalt-60 stereotactic radiosurgery units

    International Nuclear Information System (INIS)

    Nakazawa, Hisato; Komori, Masataka; Uchiyama, Yukio; Hagiwara, Masahiro; Hayashi, Naoki

    2014-01-01

    The brand-new version of gamma knife, Perfexion, is equipped with an automatic collimator arrangement system that does not require manual collimator exchange and a couch-traveling system that is approximately ten times faster than Model C, so treatment time with multiple shots is assumed to remain within a clinically acceptable range. In this study, the treatment plans for Model C and Perfexion were compared from the viewpoint of number of shots, coverage, selectivity, conformity, and gradient in planning target volume (PTV) coverage. We enrolled 187 and 89 patients with vestibular schwannomas treated by Model C and Perfexion in the study. Treatment planning was created on a Leksell GammaPlan workstation. The mean PTV was 5.2 ml (range 0.1-18.4 ml) in Model C and 4.1 ml (range 0.1-32.1 ml) in Perfexion. The mean shot number for Model C and Perfexion was 11 (range 2-27) and 16 (range 1-41) at the isodose contour of 40-60%, respectively. The mean PTV coverage was 94% (range 73-100%) and 98% (range 91-100%), and the mean PTV selectivity was 83% (range 46-98%) and 87% (range 63-97%) for Model C and Perfexion, respectively. The mean conformity index was 1.15 (range 0.81-2.02) and 1.14 (range 0.97-1.57), and the mean gradient index was 2.82 (range 2.37-3.35) and 2.91 (range 2.55-4.48) for Model C and Perfexion, respectively. In Perfexion, better PTV coverage and selectivity were achieved by using an excessively large number of shots. In addition, the use of a small collimator in Perfexion produced a steeper dose gradient. Our comparative research demonstrated the greater clinical usefulness of Perfexion. (author)

  17. Scanning electron microscopy of mouse intestinal mucosa after cobalt 60 and D-T neutron irradiation

    International Nuclear Information System (INIS)

    Hamlet, R.; Carr, K.R.; Toner, P.G.; Nias, A.H.W.

    1976-01-01

    The stem-cell population of the intestinal crypt is an important model system in experimental radiobiology. Standardized techniques have been developed to allow quantitation of the response of crypt cells to radiation injury following doses of 0 to 2 krad of D-T neutrons or 60 Co γ rays. These techniques rely on the identification of regenerating crypt cells three-and-a-half days after irradiation. The results were expressed as the number of regenerating crypts per circumference of small intestine, as determined by conventional histological examination; the more profound the injury, the smaller the the crypt count. The practical relevance of crypt-counting techniques to clinical radiotherapy is limited by their relative insensitivity; the dose levels commonly used in fractionated radiotherapy produced no detectable response. Scanning electron microscopy of the mucosal surface provided a more sensitive measure of radiation injury. The earliest detectable changes occurred at the level of 300 rad of γ radiation, well below the threshold of the crypt-counting technique. At around 1,000 rad, where the first drop in crypt counts occurred, there were well-marked morphological changes which became more severe with increasing dose levels. Some differences have been observed between the morphological effects of γ and neutron irradiation at points of radiobiological equivalence in terms of crypt counts (using RBE value of about 2). The changes observed may reflect more than the disruption of epithelial cell kinetics. Mucosal morphology is the total expression of many different biological parameters of which the regenerative ability of the crypt cells is only one. The surface microanatomy of the gut may be the most sensitive indicator of radiation injury which is conveniently available for study. (author)

  18. Guidelines for industrial radiation sterilization of disposable medical products (Cobalt-60 gamma irradiation)

    International Nuclear Information System (INIS)

    1990-01-01

    This IAEA document is aimed at providing necessary guidance on standards and criteria and assistance to Member States, particularly developing countries, in their attempts to properly set up facilities for industrial radiation sterilization of duly-manufactured medical products by exposure to Co-60 gamma radiation. The contents of the guidelines have therefore been designed, as far as practicable, to reflect the practices and procedures currently employed in the processing of the majority of the radiation-sterilized medical products being produced worldwide. Consequently, this document has attempted to present to its users, for information and for action, all the relevant features of the standard criteria as are currently in existence under the auspices of the various authoritative national and/or regional Codes or Guides. The potential user(s) from Member States are expected to freely decide which of the various standards as enumerated in the Guidelines document should be considered for inclusion or exclusion either partially or totally in the context of the formulation of their own nationally-acceptable guidelines. Refs and tabs

  19. Developed and applications of a method for dose comparation of the cobalt 60 in radiotherapy

    International Nuclear Information System (INIS)

    Leao, J.L.B.

    1975-01-01

    IAEA and WHO developed a postal intercomparison program for measuring the output of Co-60 therapy units all over the world. This work reports first results of an modified postal intercomparison based on IAEA/WHO program. A mailable 10 x 10 x 10,5cm Mix-D phantom with embedded TLD dosimeters, films and field markers of lead and a questionary were developed to obtain not only informations regarding output of Co-60 therapy machines but also to get information about alignment, field homogeneity, dose calculations, field size and surface dose. This program was field tested in 10 different Radiotherapy Centers. The results of this intercomparison gave a spread of the absorbed dose from 78 rads to 127 rads for the 100 rads asked for in 5cm depth of the phantom. Variation in the prescribed fieldsize of 6 x 6cm were between 30cm 2 and 100cm 2 . In half of the cases inhomogeneity of the radiation field was spotted [pt

  20. Selective extraction of cobalt 60 and radium on CSA's SIMTM system

    International Nuclear Information System (INIS)

    Denton, M.S.; Higgins, I.R.

    1988-01-01

    CSA, has developed and promoted a new ground/well water treatment media and support system for hydrogen sulfide, iron, and manganese called The SIM System. This media was also found to have a selective affinity for arsenic, selenium, antimony, bismuth and lead. All heavy metals have not been checked, but of special rad-waste interest is Co-60 and Ra-226. Barium has been used as a stand-in for Ra in the lab, but both Co and Ba have exhibited very high affinities from Oak Ridge waters. A very attractive feature is that the adsorbed metals may be eluted with a minimum of acid, unlike ion exchangers that regenerate with difficulty or zeolites which dissolve in acids. This opens up the new dimension of extraction/concentration of these contaminants. Ordinary water softening ion exchange resin is excellent for extraction of Ra from drinking water, but, as mentioned, regenerates with great difficulty. The SIM media may be used for pre-treatment with the acid regenerant reloaded on ordinary resin for a very high concentration of Ra, or Co, for final disposal. The very stable SIM media may also be disposed of directly. Strontium (Sr-90) affinity isn't as great as for barium, but is greater than calcium. The separation factor of SIM for Sr/Ca may well be better than the value of two (2) observed for ordinary cation resin. Further studies are being made to demonstrate the full potential of this selective media for certain rad-wastes

  1. Radiation safety assessment of cobalt 60 external beam radiotherapy using the risk-matrix method

    International Nuclear Information System (INIS)

    Dumenigo, C; Vilaragut, J.J.; Ferro, R.; Guillen, A.; Ramirez, M.L.; Ortiz Lopez, P.; Rodriguez, M.; McDonnell, J.D.; Papadopulos, S.; Pereira, P.P.; Goncalvez, M.; Morales, J.; Larrinaga, E.; Lopez Morones, R.; Sanchez, R.; Delgado, J.M.; Sanchez, C.; Somoano, F.

    2008-01-01

    External beam radiotherapy is the only practice in which humans are placed directly in a radiation beam with the intention to deliver a very high dose. This is why safety in radiotherapy is very critical, and is a matter of interest to both radiotherapy departments and regulatory bodies. Accidental exposures have occurred throughout the world, thus showing the need for systematic safety assessments, capable to identify preventive measures and to minimize consequences of accidental exposure. Risk-matrix is a systematic approach which combines the relevant event features to assess the overall risk of each particular event. Once an event sequence is identified, questions such as how frequent the event, how severe the potential consequences and how reliable the existing safety measures are answered in a risk-matrix table. The ultimate goal is to achieve that the overall risk for events with severe consequences should always be low o very low. In the present study, the risk-matrix method has been applied to an hypothetical radiotherapy department, which could be equivalent to an upper level hospital of the Ibero American region, in terms of safety checks and preventive measures. The application of the method has identified 76 event sequences and revealed that the hypothetical radiotherapy department is sufficiently protected (low risk) against them, including 23 event sequences with severe consequences. The method has revealed that the risk of these sequences could grow to high level if certain specific preventive measures were degraded with time. This study has identified these preventive measures, thus facilitating a rational allocation of resources in regular controls to detect any loss of reliability. The method has proven to have an important practical value and is affordable at hospital level. The elaborated risk-matrix can be easily adapted to local circumstances, in terms of existing controls and safety measures. This approach can help hospitals to identify vulnerable aspects and improvements required and regulatory bodies to improve the quality of their inspections. (author)

  2. Activation measurements for thermal neutrons. Part A. Cobalt (60Co) activation

    International Nuclear Information System (INIS)

    Kerr, George D.; Shizuma, Kiyoshi; Endo, Satoru; Maruyama, Takashi; Cullings, Harry M.; Komura, Kazuhisa; Okumura, Yutaka; Egbert, Stephen D.

    2005-01-01

    The 60 Co measurements at Hiroshima and Nagasaki were reviewed and compared with the results of the new DS02 calculations for the two cities. Some corrections were made to previously published data from the 1965 measurements of JNIRS, ground ranges of all of the 60 Co measurements were reviewed and new ground ranges were determined when possible by transforming sample coordinates to the new city maps for Hiroshima and Nagasaki, and transmission factors were investigated for a number of samples used in the 60 Co measurements. Transmission factors were not calculated for all samples used in the 60 Co measurements but some general rules were given for estimating transmission factors for these samples. Experimental measurements of the background 60 Co activity from environmental neutrons were also reviewed, and it was found that the 60 Co background from environmental neutrons was not an important factor in the 60 Co measurements of bomb-induced activity at either city. (J.P.N.)

  3. Scanning electron microscopy of mouse intestinal mucosa after cobalt 60 and D-T neutron irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Hamlet, R [Belvidere Hospital, Glasgow (UK). Institute of Radiotherapeutics and Oncology; Carr, K R; Toner, P G; Nias, A H.W.

    1976-07-01

    The stem-cell population of the intestinal crypt is an important model system in experimental radiobiology. Standardized techniques have been developed to allow quantitation of the response of crypt cells to radiation injury following doses of 0 to 2 krad of D-T neutrons or /sup 60/Co ..gamma.. rays. These techniques rely on the identification of regenerating crypt cells three-and-a-half days after irradiation. The results were expressed as the number of regenerating crypts per circumference of small intestine, as determined by conventional histological examination; the more profound the injury, the smaller the the crypt count. The practical relevance of crypt-counting techniques to clinical radiotherapy is limited by their relative insensitivity; the dose levels commonly used in fractionated radiotherapy produced no detectable response. Scanning electron microscopy of the mucosal surface provided a more sensitive measure of radiation injury. The earliest detectable changes occurred at the level of 300 rad of ..gamma.. radiation, well below the threshold of the crypt-counting technique. At around 1,000 rad, where the first drop in crypt counts occurred, there were well-marked morphological changes which became more severe with increasing dose levels. Some differences have been observed between the morphological effects of ..gamma.. and neutron irradiation at points of radiobiological equivalence in terms ofCrypt counts (using RBE value of about 2). The changes observed may reflect more than the disruption of epithelial cell kinetics. Mucosal morphology is the total expression of many different biological parameters of which the regenerative ability of the crypt cells is only one. The surface microanatomy of the gut may be the most sensitive indicator of radiation injury which is conveniently available for study.

  4. Graft polymerization of styrene onto starch by simultaneous cobalt-60 irradiation

    International Nuclear Information System (INIS)

    Fanta, G.F.; Burr, R.C.; Doane, W.M.; Russell, C.R.

    1977-01-01

    Starch-g-polystyrene copolymers have been prepared by the simultaneous 60 Co irradiation of starch--styrene mixtures, and copolymers have been characterized with respect to weight per cent polystyrene (% add-on) and also the molecular weight and molecular weight distribution of polystyrene grafts. In a typical polymerization, 4g each of starch and styrene were blended with 1 ml water and 1.5 ml of an organic solvent; the resulting semisolid paste was irradiated to a total dose of 1 Mrad. With ethylene glycol, acetonitrile, ethanol, methanol, acetone, and dimethylformamide as the organic solvent, values for % add-on ranged from 24% to 29%. The highest % add-on (43%) and the highest conversion of styrene to grafted polymer (76%) were obtained when the organic solvent was omitted, and water alone was used. When water was also omitted, polymerization of styrene was negligible; however, graft copolymer was formed in the absence of water when either ethylene glycol or ethanol was added. Attempts were unsuccessful to achieve a % add-on greater than 43% by doubling the amount of styrene in the polymerization recipe. Mixtures of equal weights of starch and styrene are relatively nonviscous, but these mixtures thicken when either water or ethylene glycol is blended in. Reasons for this thickening action and the possible influence of thickening on the graft polymerization reaction were explored

  5. Gray Wolves as Climate Change Buffers in Yellowstone

    OpenAIRE

    Wilmers Christopher C; Getz Wayne M; Getz Wayne M

    2005-01-01

    Understanding the mechanisms by which climate and predation patterns by top predators co-vary to affect community structure accrues added importance as humans exert growing influence over both climate and regional predator assemblages. In Yellowstone National Park, winter conditions and reintroduced gray wolves (Canis lupus) together determine the availability of winter carrion on which numerous scavenger species depend for survival and reproduction. As climate changes in Yellowstone, therefo...

  6. Gray wolves as climate change buffers in Yellowstone.

    OpenAIRE

    Christopher C Wilmers; Wayne M Getz

    2005-01-01

    Understanding the mechanisms by which climate and predation patterns by top predators co-vary to affect community structure accrues added importance as humans exert growing influence over both climate and regional predator assemblages. In Yellowstone National Park, winter conditions and reintroduced gray wolves (Canis lupus) together determine the availability of winter carrion on which numerous scavenger species depend for survival and reproduction. As climate changes in Yellowstone, therefo...

  7. Production of hybrids between western gray wolves and western coyotes.

    Directory of Open Access Journals (Sweden)

    L David Mech

    Full Text Available Using artificial insemination we attempted to produce hybrids between captive, male, western, gray wolves (Canis lupus and female, western coyotes (Canis latrans to determine whether their gametes would be compatible and the coyotes could produce and nurture offspring. The results contribute new information to an ongoing controversy over whether the eastern wolf (Canis lycaon is a valid unique species that could be subject to the U. S. Endangered Species Act. Attempts with transcervically deposited wolf semen into nine coyotes over two breeding seasons yielded three coyote pregnancies. One coyote ate her pups, another produced a resorbed fetus and a dead fetus by C-section, and the third produced seven hybrids, six of which survived. These results show that, although it might be unlikely for male western wolves to successfully produce offspring with female western coyotes under natural conditions, western-gray-wolf sperm are compatible with western-coyote ova and that at least one coyote could produce and nurture hybrid offspring. This finding in turn demonstrates that gamete incompatibility would not have prevented western, gray wolves from inseminating western coyotes and thus producing hybrids with coyote mtDNA, a claim that counters the view that the eastern wolf is a separate species. However, some of the difficulties experienced by the other inseminated coyotes tend to temper that finding and suggest that more experimentation is needed, including determining the behavioral and physical compatibility of western gray wolves copulating with western coyotes. Thus although our study adds new information to the controversy, it does not settle it. Further study is needed to determine whether the putative Canis lycaon is indeed a unique species.

  8. Evaluation of Subependymal Gray Matter Heterotopias on Fetal MRI.

    Science.gov (United States)

    Nagaraj, U D; Peiro, J L; Bierbrauer, K S; Kline-Fath, B M

    2016-04-01

    Subependymal grey matter heterotopias are seen in a high proportion of children with Chiari II malformation and are potentially clinically relevant. However, despite its growing use, there is little in the literature describing its detection on fetal MRI. Our aim was to evaluate the accuracy in diagnosing subependymal gray matter heterotopias in fetuses with spinal dysraphism on fetal MR imaging. This study is a retrospective analysis of 203 fetal MRIs performed at a single institution for spinal dysraphism during a 10-year period. Corresponding obstetric sonography, postnatal imaging, and clinical/operative reports were reviewed. Of the fetal MRIs reviewed, 95 fetuses were included in our analysis; 23.2% (22/95) were suspected of having subependymal gray matter heterotopias on fetal MR imaging prospectively. However, only 50% (11/22) of these cases were confirmed on postnatal brain MR imaging. On postnatal brain MR imaging, 28.4% (27/95) demonstrated imaging findings consistent with subependymal gray matter heterotopia. Only 40.7% (11/27) of these cases were prospectively diagnosed on fetal MR imaging. Fetal MR imaging is limited in its ability to identify subependymal gray matter heterotopias in fetuses with spinal dysraphism. It is believed that this limitation relates to a combination of factors, including artifacts from fetal motion, the very small size of fetal neuroanatomy, differences in imaging techniques, and, possibly, irregularity related to denudation of the ependyma/subependyma in the presence of spinal dysraphism and/or stretching of the germinal matrix in ventriculomegaly. © 2016 by American Journal of Neuroradiology.

  9. Exposing asymmetric gray matter vulnerability in amyotrophic lateral sclerosis

    OpenAIRE

    Devine, Matthew S.; Pannek, Kerstin; Coulthard, Alan; McCombe, Pamela A.; Rose, Stephen E.; Henderson, Robert D.

    2015-01-01

    Limb weakness in amyotrophic lateral sclerosis (ALS) is typically asymmetric. Previous studies have identified an effect of limb dominance on onset and spread of weakness, however relative atrophy of dominant and non-dominant brain regions has not been investigated. Our objective was to use voxel-based morphometry (VBM) to explore gray matter (GM) asymmetry in ALS, in the context of limb dominance. 30 ALS subjects were matched with 17 healthy controls. All subjects were right-handed. Each und...

  10. Complete permutation Gray code implemented by finite state machine

    Directory of Open Access Journals (Sweden)

    Li Peng

    2014-09-01

    Full Text Available An enumerating method of complete permutation array is proposed. The list of n! permutations based on Gray code defined over finite symbol set Z(n = {1, 2, …, n} is implemented by finite state machine, named as n-RPGCF. An RPGCF can be used to search permutation code and provide improved lower bounds on the maximum cardinality of a permutation code in some cases.

  11. Effect of protracted whole-body gamma irradiation with 6.7 Gy and 4.8 Gy (700 and 500 R) on trypsin inhibition activity of blood, cervical mucus and on morphological structure of cervix in ewes

    International Nuclear Information System (INIS)

    Molnarova, M.; Arendarcik, J.; Molnar, P.

    1984-01-01

    The pattern of changes in the trypsin inhibition activities (TIA) of blood plasma, cervical mucus and the morphological structure of the cervix was studied in ewes exposed to 60 Co radiation for seven and five days, the radiation doses being 6.7 Gy and 4.8 Gy, respectively. During exposure, the group of ewes irradaited with 4.8 Gy was given the Roboran vitamin addition and following irradiation ampicillin (5250 mg). TIA was determined from retardation of the hydrolysis of the synthetic substrate N-alpha-tosyl-p-nitroanilide by bovine trypsin; the TIA was expressed as the percentage of inhibited trypsin. Almost all the studied TIA values of blood plasma and cervical mucus were increased in the irradiated animals, the range being from 103.1 to 155.0% of the levels for non-irradiated ewes. A reduction was recorded only in the total TIA of blood plasma in the group irradiated with a dose of 6.7 Gy (83.1% of the values for non-irradiated animals). In the group of animals irradiated with 4.8 Gy and non Roboran administered, the TIA of cervical mucus was observed to decrease to 92.4%. It was found during the study of changes in the proportion of glands in the stroma and changes in epithelium thickness in the mucous membrane of the cervix uteri that the irradiated ewes had the epithelium thickness reduced to 95.3% to 65.5% and that their stromal gland number decreased to 75.4% to 79.7% of that recorded in non-irradiated animals. It was only in the group given the Roboran supplement that an increase to 123.7% of the gland number for untreated ewes was recorded on the tenth day after termination of the irradiation

  12. Response of mesenchymal stem cells in mice to 3.5 Gy X-ray irradiation

    International Nuclear Information System (INIS)

    Su Wenxia; Liu Huimin; Chen Yonghong; Zeng Wen; Liu Wenli; Sun Hanying

    2011-01-01

    Objective: To investigate the response of mesenchymal stem cells in mice to medium-dose X-ray irradiation in vitro. Methods: The mouse mesenchymal stem cell line C3H10T1/2 was submitted to 3.5 Gy X-ray irradiation. Hoechst33258 staining of adherent cells and Annexin V-FITC staining and flow cytometry analysis of suspension cells were performed respectively to assess cellular apoptosis at 3, 6, 12, 24, 48, 72 h and 1 week after irradiation. SA-β-gal staining was performed to analyze the cellular senescence at 24, 48, 72 h and 1 week after irradiation. The mRNA level of both Fas with its ligand FasL and p53 with its downstream target p21 WAF1 were measured by Real-Time PCR analysis. The expression of Fas protein was determined by immunofluorescence staining. Results: An increased apoptosis was observed at 3 h after irradiation with apoptosis rate 11.72% ± 1.61% (t=9.01, P<0.01), the apoptosis rate reached the peak level at 12 h 20.52% ± 1.96% (t=16.27, P<0.01), and then declined progressively to normal level at 48 h 4.93% ±0.46% (t=2.26, P>0.05). The SA-β-gal positive rate of post-radiation cells at 72 h was 53.33% ± 5.62%, significantly higher than that of normal control 3.24% ± 0.39% (t=17.77, P<0.01). The level of Fas, FasL mRNA was found to be elevated 3 h after irradiation with a peak at 12 h, and no differences were found l week later. The level of Fas protein was observed to reach the peak at 12 h after irradiation. The occurrence of peak level of Fas/FasL mRNA and protein was consistent with that of apoptosis of C3H10T1/2 cell. A transient up-regulation of p53, p21 WAF1 mRNA expression was found at 12 h after irradiation followed by a significant increase later at 72 h after irradiation. The occurrence of the two peaks of p53, p21 WAF1 mRNA expression were coincident with that of cellular apoptosis and senescence, respectively. The levels of p53, p21 WAF1 mRNA in senescence group were significantly higher than those of apoptosis group (t=17.85, 13

  13. Tetrahedral gray code for visualization of genome information.

    Directory of Open Access Journals (Sweden)

    Natsuhiro Ichinose

    Full Text Available We propose a tetrahedral Gray code that facilitates visualization of genome information on the surfaces of a tetrahedron, where the relative abundance of each [Formula: see text]-mer in the genomic sequence is represented by a color of the corresponding cell of a triangular lattice. For biological significance, the code is designed such that the [Formula: see text]-mers corresponding to any adjacent pair of cells differ from each other by only one nucleotide. We present a simple procedure to draw such a pattern on the development surfaces of a tetrahedron. The thus constructed tetrahedral Gray code can demonstrate evolutionary conservation and variation of the genome information of many organisms at a glance. We also apply the tetrahedral Gray code to the honey bee (Apis mellifera genome to analyze its methylation structure. The results indicate that the honey bee genome exhibits CpG overrepresentation in spite of its methylation ability and that two conserved motifs, CTCGAG and CGCGCG, in the unmethylated regions are responsible for the overrepresentation of CpG.

  14. Gray matter and white matter abnormalities in online game addiction

    International Nuclear Information System (INIS)

    Weng, Chuan-Bo; Qian, Ruo-Bing; Fu, Xian-Ming; Lin, Bin; Han, Xiao-Peng; Niu, Chao-Shi; Wang, Ye-Han

    2013-01-01

    Online game addiction (OGA) has attracted greater attention as a serious public mental health issue. However, there are only a few brain magnetic resonance imaging studies on brain structure about OGA. In the current study, we used voxel-based morphometry (VBM) analysis and tract-based spatial statistics (TBSS) to investigate the microstructural changes in OGA and assessed the relationship between these morphology changes and the Young's Internet Addiction Scale (YIAS) scores within the OGA group. Compared with healthy subjects, OGA individuals showed significant gray matter atrophy in the right orbitofrontal cortex, bilateral insula, and right supplementary motor area. According to TBSS analysis, OGA subjects had significantly reduced FA in the right genu of corpus callosum, bilateral frontal lobe white matter, and right external capsule. Gray matter volumes (GMV) of the right orbitofrontal cortex, bilateral insula and FA values of the right external capsule were significantly positively correlated with the YIAS scores in the OGA subjects. Our findings suggested that microstructure abnormalities of gray and white matter were present in OGA subjects. This finding may provide more insights into the understanding of the underlying neural mechanisms of OGA

  15. Gray matter and white matter abnormalities in online game addiction

    Energy Technology Data Exchange (ETDEWEB)

    Weng, Chuan-Bo, E-mail: send007@163.com [Department of Neurosurgery, Anhui Provincial Hospital Affiliated to Anhui Medical University, 17 Lujiang Road, Hefei, Ahui Province 230001 (China); School of Neurosurgery, Anhui Medical University, 81 Meishang Road, Hefei, Anhui Province 230032 (China); Qian, Ruo-Bing, E-mail: rehomail@163.com [Department of Neurosurgery, Anhui Provincial Hospital Affiliated to Anhui Medical University, 17 Lujiang Road, Hefei, Ahui Province 230001 (China); Anhui Provincial Institute of Stereotactic Neurosurgery, 9 Lujiang Road, Hefei, Ahui Province 230001 (China); Fu, Xian-Ming, E-mail: 506537677@qq.com [Department of Neurosurgery, Anhui Provincial Hospital Affiliated to Anhui Medical University, 17 Lujiang Road, Hefei, Ahui Province 230001 (China); Anhui Provincial Institute of Stereotactic Neurosurgery, 9 Lujiang Road, Hefei, Ahui Province 230001 (China); Lin, Bin, E-mail: 274722758@qq.com [School of Neurosurgery, Anhui Medical University, 81 Meishang Road, Hefei, Anhui Province 230032 (China); Han, Xiao-Peng, E-mail: hanxiaopeng@163.com [Department of Psychology, Anhui Provincial Hospital Affiliated to Anhui Medical University, 17 Lujiang Road, Hefei, Ahui Province 230001 (China); Niu, Chao-Shi, E-mail: niuchaoshi@163.com [Department of Neurosurgery, Anhui Provincial Hospital Affiliated to Anhui Medical University, 17 Lujiang Road, Hefei, Ahui Province 230001 (China); Anhui Provincial Institute of Stereotactic Neurosurgery, 9 Lujiang Road, Hefei, Ahui Province 230001 (China); Wang, Ye-Han, E-mail: wangyehan@163.com [Department of Neurosurgery, Anhui Provincial Hospital Affiliated to Anhui Medical University, 17 Lujiang Road, Hefei, Ahui Province 230001 (China); Anhui Provincial Institute of Stereotactic Neurosurgery, 9 Lujiang Road, Hefei, Ahui Province 230001 (China)

    2013-08-15

    Online game addiction (OGA) has attracted greater attention as a serious public mental health issue. However, there are only a few brain magnetic resonance imaging studies on brain structure about OGA. In the current study, we used voxel-based morphometry (VBM) analysis and tract-based spatial statistics (TBSS) to investigate the microstructural changes in OGA and assessed the relationship between these morphology changes and the Young's Internet Addiction Scale (YIAS) scores within the OGA group. Compared with healthy subjects, OGA individuals showed significant gray matter atrophy in the right orbitofrontal cortex, bilateral insula, and right supplementary motor area. According to TBSS analysis, OGA subjects had significantly reduced FA in the right genu of corpus callosum, bilateral frontal lobe white matter, and right external capsule. Gray matter volumes (GMV) of the right orbitofrontal cortex, bilateral insula and FA values of the right external capsule were significantly positively correlated with the YIAS scores in the OGA subjects. Our findings suggested that microstructure abnormalities of gray and white matter were present in OGA subjects. This finding may provide more insights into the understanding of the underlying neural mechanisms of OGA.

  16. Regional gray matter variation in male-to-female transsexualism

    Science.gov (United States)

    Luders, Eileen; Sánchez, Francisco J.; Gaser, Christian; Toga, Arthur W.; Narr, Katherine L.; Hamilton, Liberty S.; Vilain, Eric

    2009-01-01

    Gender identity—one's sense of being a man or a woman—is a fundamental perception experienced by all individuals that extends beyond biological sex. Yet, what contributes to our sense of gender remains uncertain. Since individuals who identify as transsexual report strong feelings of being the opposite sex and a belief that their sexual characteristics do not reflect their true gender, they constitute an invaluable model to understand the biological underpinnings of gender identity. We analyzed MRI data of 24 male-to-female (MTF) transsexuals not yet treated with cross-sex hormones in order to determine whether gray matter volumes in MTF transsexuals more closely resemble people who share their biological sex (30 control men), or people who share their gender identity (30 control women). Results revealed that regional gray matter variation in MTF transsexuals is more similar to the pattern found in men than in women. However, MTF transsexuals show a significantly larger volume of regional gray matter in the right putamen compared to men. These findings provide new evidence that transsexualism is associated with distinct cerebral pattern, which supports the assumption that brain anatomy plays a role in gender identity. PMID:19341803

  17. POD Model Reconstruction for Gray-Box Fault Detection

    Science.gov (United States)

    Park, Han; Zak, Michail

    2007-01-01

    Proper orthogonal decomposition (POD) is the mathematical basis of a method of constructing low-order mathematical models for the "gray-box" fault-detection algorithm that is a component of a diagnostic system known as beacon-based exception analysis for multi-missions (BEAM). POD has been successfully applied in reducing computational complexity by generating simple models that can be used for control and simulation for complex systems such as fluid flows. In the present application to BEAM, POD brings the same benefits to automated diagnosis. BEAM is a method of real-time or offline, automated diagnosis of a complex dynamic system.The gray-box approach makes it possible to utilize incomplete or approximate knowledge of the dynamics of the system that one seeks to diagnose. In the gray-box approach, a deterministic model of the system is used to filter a time series of system sensor data to remove the deterministic components of the time series from further examination. What is left after the filtering operation is a time series of residual quantities that represent the unknown (or at least unmodeled) aspects of the behavior of the system. Stochastic modeling techniques are then applied to the residual time series. The procedure for detecting abnormal behavior of the system then becomes one of looking for statistical differences between the residual time series and the predictions of the stochastic model.

  18. Gray matter and white matter abnormalities in online game addiction.

    Science.gov (United States)

    Weng, Chuan-Bo; Qian, Ruo-Bing; Fu, Xian-Ming; Lin, Bin; Han, Xiao-Peng; Niu, Chao-Shi; Wang, Ye-Han

    2013-08-01

    Online game addiction (OGA) has attracted greater attention as a serious public mental health issue. However, there are only a few brain magnetic resonance imaging studies on brain structure about OGA. In the current study, we used voxel-based morphometry (VBM) analysis and tract-based spatial statistics (TBSS) to investigate the microstructural changes in OGA and assessed the relationship between these morphology changes and the Young's Internet Addiction Scale (YIAS) scores within the OGA group. Compared with healthy subjects, OGA individuals showed significant gray matter atrophy in the right orbitofrontal cortex, bilateral insula, and right supplementary motor area. According to TBSS analysis, OGA subjects had significantly reduced FA in the right genu of corpus callosum, bilateral frontal lobe white matter, and right external capsule. Gray matter volumes (GMV) of the right orbitofrontal cortex, bilateral insula and FA values of the right external capsule were significantly positively correlated with the YIAS scores in the OGA subjects. Our findings suggested that microstructure abnormalities of gray and white matter were present in OGA subjects. This finding may provide more insights into the understanding of the underlying neural mechanisms of OGA. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Brain gray matter structural network in myotonic dystrophy type 1.

    Directory of Open Access Journals (Sweden)

    Atsuhiko Sugiyama

    Full Text Available This study aimed to investigate abnormalities in structural covariance network constructed from gray matter volume in myotonic dystrophy type 1 (DM1 patients by using graph theoretical analysis for further clarification of the underlying mechanisms of central nervous system involvement. Twenty-eight DM1 patients (4 childhood onset, 10 juvenile onset, 14 adult onset, excluding three cases from 31 consecutive patients who underwent magnetic resonance imaging in a certain period, and 28 age- and sex- matched healthy control subjects were included in this study. The normalized gray matter images of both groups were subjected to voxel based morphometry (VBM and Graph Analysis Toolbox for graph theoretical analysis. VBM revealed extensive gray matter atrophy in DM1 patients, including cortical and subcortical structures. On graph theoretical analysis, there were no significant differences between DM1 and control groups in terms of the global measures of connectivity. Betweenness centrality was increased in several regions including the left fusiform gyrus, whereas it was decreased in the right striatum. The absence of significant differences between the groups in global network measurements on graph theoretical analysis is consistent with the fact that the general cognitive function is preserved in DM1 patients. In DM1 patients, increased connectivity in the left fusiform gyrus and decreased connectivity in the right striatum might be associated with impairment in face perception and theory of mind, and schizotypal-paranoid personality traits, respectively.

  20. Biological dosimetry of low doses (0.05 - 0.4 Gy) with micronucleus dicentrics and chromosome fragments

    International Nuclear Information System (INIS)

    Rodriguez, L.; Sanchez, E.; Linares, C.; Navlet, J.

    1997-01-01

    This study was carried out within the framework of the agreement between the National Nuclear Safety Council and the University of Alcala of Hernares and in co-operation with the Radiological Service and the Radiation Protection Unit of the Gregorio Maranon General Hospital of Madrid, where irradiations were performed. Blood samples were taken of 4 individuals irradiated with 6 doses of gamma rays between 0.05 Gy and 0.40 Gy, leaving an aliquot dose of 0 Gy. Cultures of lymphocytes for the study of dicentric chromosomes (DC) and chromosomal fragments (fr), stopping the first mitosis after postirradiation with Colcemid. A study of micronuclei (MN) in binuclear cells was also performed, interrupting the first cytokinesis after postirradiation with citocalasina B. After the corresponding studies with optical microscope, statistical analysis was made on the observed data on DC, fr and MN. We made a multiple linear regression analysis of the data of the 4 individuals. We obtained the average of the 4 individuals for each variable and dose and performed the variance analysis. According to our study, neither the DC nor the MN are valid dosemeters for lower doses up to 0.4 Gy. Nevertheless there are indications that the fragments are correlated with the dose to these levels. By increasing both the points of dose and the number of metaphases studied, we believe that a dose curve can be done that would allow to estimate with a reasonable degree of confidence the dose received by a sample irradiated

  1. A thermoluminescence study of mineral silicates extracted from herbs in the dose range 0.5–5 Gy

    International Nuclear Information System (INIS)

    Della Monaca, Sara; Fattibene, Paola; Bortolin, Emanuela

    2013-01-01

    The presence of silicates in many personal objects suggests their potential use at low dose as fortuitous dosimeter in an accidental radiological exposure, when conventional dosimetry is not available. The goal of the present work is the dosimetric characterization of mineral silicates extracted from the plant Hibiscus Sabdariffa L, known as Jamaica flower, in the dose range 0.5–5 Gy. By studying the radiation-induced signal in time, the temperature integration region between 210 °C and 250 °C was found to be the most stable and also reduced the effects of thermal fading in the dose reconstruction process; the dose response curve was linear between 0.5 Gy and 5 Gy. By checking the change in sensitivity after repeated exposures to ionizing radiations and to high temperature heating, no variation in the glow curve shape or peak intensities were detected. To eliminate a pre-existing background signal, all the characterization measurements were performed with aliquots “annealed” by a preliminary readout of the TL. - Highlights: • Glow curves change in shape and intensity just in the first 3 days after irradiation. • The dose response is linear in the dose range 0.5–5 Gy. • The curve shape or intensity don't change after repeated exposures and heatings. • Encouraging results were obtained in the dose recovery test

  2. Development of a 10 kGy(Si) rad hard controller for a mobile robot using COTS

    International Nuclear Information System (INIS)

    Alexandre, J.M.; Marceau, M.

    1999-01-01

    The CEA has developed a 10 kGy(Si) hardened controller using only COTS (Commercial-Off-The-Shelf devices), to equip the mobile robot Andros. An electronic architecture adapted to the constraint of hardening have been carried out, leading to the construction of a complete set of electronics modules (power electronic, control computer). (authors)

  3. Creativity Beyond Originality: György Pálfi's FINAL CUT as Narrative Supercut : [an audiovisual essay / videographic adaptation

    NARCIS (Netherlands)

    Kiss, Miklós

    2015-01-01

    György Pálfi’s FINAL CUT – LADIES & GENTLEMEN (2012) is a movie made out of other movies, literally. It is Vimeo’s and YouTube’s beloved film mashups and supercuts on steroids. Nevertheless, Final Cut does not only offer a genre-, style-, year- or author- and actor-bound fan-made compilation; it is

  4. Palliative radiation therapy for AIDS-associated Kaposi's sarcoma by using a single fraction of 800 cGy

    NARCIS (Netherlands)

    de Wit, R.; Smit, W. G.; Veenhof, K. H.; Bakker, P. J.; Oldenburger, F.; González, D. G.

    1990-01-01

    A single radiation fraction of 800 cGy was used in the treatment of acquired immunodeficiency syndrome (AIDS)-associated Kaposi's sarcoma (KS). A total of 74 radiation treatments was given to a total of 31 patients. Of all 74 evaluable treatments, there were 25 objective major responses (6 complete,

  5. Histogram and gray level co-occurrence matrix on gray-scale ultrasound images for diagnosing lymphocytic thyroiditis.

    Science.gov (United States)

    Shin, Young Gyung; Yoo, Jaeheung; Kwon, Hyeong Ju; Hong, Jung Hwa; Lee, Hye Sun; Yoon, Jung Hyun; Kim, Eun-Kyung; Moon, Hee Jung; Han, Kyunghwa; Kwak, Jin Young

    2016-08-01

    The objective of the study was to evaluate whether texture analysis using histogram and gray level co-occurrence matrix (GLCM) parameters can help clinicians diagnose lymphocytic thyroiditis (LT) and differentiate LT according to pathologic grade. The background thyroid pathology of 441 patients was classified into no evidence of LT, chronic LT (CLT), and Hashimoto's thyroiditis (HT). Histogram and GLCM parameters were extracted from the regions of interest on ultrasound. The diagnostic performances of the parameters for diagnosing and differentiating LT were calculated. Of the histogram and GLCM parameters, the mean on histogram had the highest Az (0.63) and VUS (0.303). As the degrees of LT increased, the mean decreased and the standard deviation and entropy increased. The mean on histogram from gray-scale ultrasound showed the best diagnostic performance as a single parameter in differentiating LT according to pathologic grade as well as in diagnosing LT. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Utilisation of gamma radiation of Cobalt-60 as quarantine treatment of medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne (Fabricius, 1792) (Coleoptera, Anobiidae) and Plodia interpunctella (Hubner, 1813) (Lepidoptera, Pyralidae); Utilizacao da radiacao gama do Cobalto-60 como tratamento quarentenario de plantas medicinais, aromaticas e condimentares desidratadas infestadas por Lasioderma serricorne (Fabricius, 1792) (Coleoptera, Anobiidae) e Plodia interpunctella (Hubner, 1813) (Lepidoptera, Pyralidae)

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Juliana Nazare

    2007-07-01

    The research had as objective the use of the gamma radiation of the Cobalto-60 as quarantine treatment of the medicinal plant, aromatic and seasoning plants dehydrated infested by Lasioderma serricorne and Plodia interpunctella determining the disinfestation doses to attend the criterion in the not emergency of adults of the species in study and analysing through the Chromatography of Thin Layer the effect of the gamma radiation of the cobalto-60 on the active principle of extract dehydrated of Chamomilla recutita, Pimpinella anisum, Origanum vulgare, Cymbopogon citratus, Ocimum basilicum and Thymus vulgaris. The work was developed in the Laboratorio de Inseticidas in the Instituto Biologico in Sao Paulo in the period of August of 2005 the June of 2007. The radiation source used gamma was an experimental irradiator of Cobalto-60, model Gamacell 220, located in the Instituto de Pesquisas Energeticas e Nucleares - IPEN, located in Sao Paulo. In the period of 30 days after the irradiation of the samples evaluated the number of adults emerged of Lasioderma serricorne and Plodia interpunctella, using the data of mortality for the analysis of Probit. Obtained 100% of not emergency of adults in the Lasioderma serricorne with the dose of 2,00 kGy and 100% of not emergency of adults in the Plodia interpunctella with the dose of 2,25 kGy. The Chromatographic Analysis of Thin Layer was to evaluate did not show chemical differences in the extracts analysed. (author)

  7. Grays Harbor and Chehalis River Improvements to Navigation Environmental Studies. Wildlife Studies at Proposed Disposal Sites in Grays Harbor, Washington,

    Science.gov (United States)

    1982-01-01

    sltand. T 𔃼~P i’ W 210 three times VtwCerI November IOC’C -nd ~co l.Etls ~ ec!,!zervc-o betxwe H -gF 12 Th -ind hl rway u- 7Plie Sicuobh. E. Cumin -s 1... stress imposed by dredge dsosal ;ictivities on these species. It is difficult to rredict the effects of establishing a salt marsh in Grays Harbor on

  8. STAYGREEN (CsSGR) is a candidate for the anthracnose (Colletotrichum orbiculare) resistance locus cla in Gy14 cucumber.

    Science.gov (United States)

    Pan, Junsong; Tan, Junyi; Wang, Yuhui; Zheng, Xiangyang; Owens, Ken; Li, Dawei; Li, Yuhong; Weng, Yiqun

    2018-04-21

    Map-based cloning identified a candidate gene for resistance to the anthracnose fungal pathogen Colletotrichum orbiculare in cucumber, which reveals a novel function for the highly conserved STAYGREEN family genes for host disease resistance in plants. Colletotrichum orbiculare is a hemibiotrophic fungal pathogen that causes anthracnose disease in cucumber and other cucurbit crops. No host resistance genes against the anthracnose pathogens have been cloned in crop plants. Here, we reported fine mapping and cloning of a resistance gene to the race 1 anthracnose pathogen in cucumber inbred lines Gy14 and WI 2757. Phenotypic and QTL analysis in multiple populations revealed that a single recessive gene, cla, was underlying anthracnose resistance in both lines, but WI2757 carried an additional minor-effect QTL. Fine mapping using 150 Gy14 × 9930 recombinant inbred lines and 1043 F 2 individuals delimited the cla locus into a 32 kb region in cucumber Chromosome 5 with three predicted genes. Multiple lines of evidence suggested that the cucumber STAYGREEN (CsSGR) gene is a candidate for the anthracnose resistance locus. A single nucleotide mutation in the third exon of CsSGR resulted in the substitution of Glutamine in 9930 to Arginine in Gy14 in CsSGR protein which seems responsible for the differential anthracnose inoculation responses between Gy14 and 9930. Quantitative real-time PCR analysis indicated that CsSGR was significantly upregulated upon anthracnose pathogen inoculation in the susceptible 9930, while its expression was much lower in the resistant Gy14. Investigation of allelic diversities in natural cucumber populations revealed that the resistance allele in almost all improved cultivars or breeding lines of the U.S. origin was derived from PI 197087. This work reveals an unknown function for the highly conserved STAYGREEN (SGR) family genes for host disease resistance in plants.

  9. Effects of acute sublethal gamma radiation exposure on aggressive behavior in male mice: A dose-response study

    International Nuclear Information System (INIS)

    Maier, D.M.; Landauer, M.R.

    1989-01-01

    The resident-intruder paradigm was used to assess the effects of gamma radiation (0, 3, 5, 7 Gray [Gy] cobalt-60) on aggressive offensive behavior in resident male mice over a 3-month period. The defensive behavior of nonirradiated intruder mice was also monitored. A dose of 3 Gy had no effect on either the residents' offensive behavior or the defensive behavior of the intruders paired with them. Doses of 5 and 7 Gy produced decreases in offensive behavior of irradiated residents during the second week postirradiation. The nonirradiated intruders paired with these animals displayed decreases in defensive behavior during this time period, indicating a sensitivity to changes in the residents' behavior. After the third week postirradiation, offensive and defensive behavior did not differ significantly between irradiated mice and sham-irradiated controls. This study suggests that sublethal doses of radiation can temporarily suppress aggressive behavior but have no apparent permanent effect on that behavior

  10. Countering Gray-Zone Hybrid Threats: An Analysis of Russias New Generation Warfare and Implications for the US Army

    Science.gov (United States)

    2016-10-18

    Threats 21 Laws and Cultural Norms as a Weapons System : When operating in the gray zone, aggressors try to use... Operational Phases 26 Countering Gray-Zone Hybrid Threats 4 Abstract The gray zone is an operating environment in...Countering Gray-Zone Hybrid Threats 6 Criminal Organizations and Networks,

  11. Grays River Watershed and Biological Assessment Final Report 2006.

    Energy Technology Data Exchange (ETDEWEB)

    May, Christopher W.; McGrath, Kathleen E.; Geist, David R. [Pacific Northwest National Laboratory; Abbe, Timothy; Barton, Chase [Herrera Environmental Consultants, Inc.

    2008-02-04

    The Grays River Watershed and Biological Assessment was funded to address degradation and loss of spawning habitat for chum salmon (Onchorhynchus keta) and fall Chinook salmon (Onchoryhnchus tshawytscha). In 1999, the National Marine Fisheries Service listed lower Columbia River chum salmon as a threatened Evolutionarily Significant Unit (ESU) under the Endangered Species Act of 1973 (ESA). The Grays River watershed is one of two remaining significant chum salmon spawning locations in this ESU. Runs of Grays River chum and Chinook salmon have declined significantly during the past century, largely because of damage to spawning habitat associated with timber harvest and agriculture in the watershed. In addition, approximately 20-25% of the then-remaining chum salmon spawning habitat was lost during a 1999 channel avulsion that destroyed an important artificial spawning channel operated by the Washington Department of Fish and Wildlife (WDFW). Although the lack of stable, high-quality spawning habitat is considered the primary physical limitation on Grays River chum salmon production today, few data are available to guide watershed management and channel restoration activities. The objectives of the Grays River Watershed and Biological Assessment project were to (1) perform a comprehensive watershed and biological analysis, including hydrologic, geomorphic, and ecological assessments; (2) develop a prioritized list of actions that protect and restore critical chum and Chinook salmon spawning habitat in the Grays River based on comprehensive geomorphic, hydrologic, and stream channel assessments; and (3) gain a better understanding of chum and Chinook salmon habitat requirements and survival within the lower Columbia River and the Grays River. The watershed-based approach to river ecosystem restoration relies on a conceptual framework that describes general relationships between natural landscape characteristics, watershed-scale habitat-forming processes, aquatic

  12. Grays River Watershed and Biological Assessment, 2006 Final Report.

    Energy Technology Data Exchange (ETDEWEB)

    May, Christopher; Geist, David [Pacific Northwest National Laboratory

    2007-04-01

    The Grays River Watershed and Biological Assessment was funded to address degradation and loss of spawning habitat for chum salmon (Onchorhynchus keta) and fall Chinook salmon (Onchoryhnchus tshawytscha). In 1999, the National Marine Fisheries Service listed lower Columbia River chum salmon as a threatened Evolutionarily Significant Unit (ESU) under the Endangered Species Act of 1973 (ESA). The Grays River watershed is one of two remaining significant chum salmon spawning locations in this ESU. Runs of Grays River chum and Chinook salmon have declined significantly during the past century, largely because of damage to spawning habitat associated with timber harvest and agriculture in the watershed. In addition, approximately 20-25% of the then-remaining chum salmon spawning habitat was lost during a 1999 channel avulsion that destroyed an important artificial spawning channel operated by the Washington Department of Fish and Wildlife (WDFW). Although the lack of stable, high-quality spawning habitat is considered the primary physical limitation on Grays River chum salmon production today, few data are available to guide watershed management and channel restoration activities. The objectives of the Grays River Watershed and Biological Assessment project were to (1) perform a comprehensive watershed and biological analysis, including hydrologic, geomorphic, and ecological assessments; (2) develop a prioritized list of actions that protect and restore critical chum and Chinook salmon spawning habitat in the Grays River based on comprehensive geomorphic, hydrologic, and stream channel assessments; and (3) gain a better understanding of chum and Chinook salmon habitat requirements and survival within the lower Columbia River and the Grays River. The watershed-based approach to river ecosystem restoration relies on a conceptual framework that describes general relationships between natural landscape characteristics, watershed-scale habitat-forming processes, aquatic

  13. Influence of the gray gases number in the weighted sum of gray gases model on the radiative heat exchange calculation inside pulverized coal-fired furnaces

    Directory of Open Access Journals (Sweden)

    Crnomarković Nenad Đ.

    2016-01-01

    Full Text Available The influence of the number of gray gases in the weighted sum in the gray gases model on the calculation of the radiative heat transfer is discussed in the paper. A computer code which solved the set of equations of the mathematical model describing the reactive two-phase turbulent flow with radiative heat exchange and with thermal equilibrium between phases inside the pulverized coal-fired furnace was used. Gas-phase radiative properties were determined by the simple gray gas model and two combinations of the weighted sum of the gray gases models: one gray gas plus a clear gas and two gray gases plus a clear gas. Investigation was carried out for two values of the total extinction coefficient of the dispersed phase, for the clean furnace walls and furnace walls covered by an ash layer deposit, and for three levels of the approximation accuracy of the weighting coefficients. The influence of the number of gray gases was analyzed through the relative differences of the wall fluxes, wall temperatures, medium temperatures, and heat transfer rate through all furnace walls. The investigation showed that there were conditions of the numerical investigations for which the relative differences of the variables describing the radiative heat exchange decrease with the increase in the number of gray gases. The results of this investigation show that if the weighted sum of the gray gases model is used, the complexity of the computer code and calculation time can be reduced by optimizing the number of gray gases. [Projekat Ministarstva nauke Republike Srbije, br. TR-33018: Increase in energy and ecology efficiency of processes in pulverized coal-fired furnace and optimization of utility steam boiler air preheater by using in-house developed software tools

  14. Medicinal Herbs Affecting Gray Hair in Iranian Traditional Medicine.

    Science.gov (United States)

    Rameshk, Maryam; Khandani, Shahram Kalantari; Raeiszadeh, Mahboobeh

    2016-05-01

    The presence of hair plays an important role in people's overall physical appearance and self-perception. As a result of increased life expectancy, the desire to look youthful plays a bigger role than ever.The use of medicinal plants is as old as mankind and the market will face many new products containing natural oils and herbs in coming years. In traditional Iranian medicine, many plants and herbal formulations are reported for hair growth as well as the improvement in hair quality. The aim of this article is to introduce effective medicinal plants in traditional Iranian medicine to prevent gray hair and advocate them as the new products. The present investigation is an overview study and has been codified by library search in the main sources of traditional Iranian medicine. In traditional Iranian medicine, three types of formulations are proposed to prevent gray hair, namely (i) treatment compounds, (ii) preventive compounds, and (iii) hair dyes to color gray hairs. Our search showed that the main parts of a plant that is used in the treatment and preventive compounds are seeds and fruits. These are primarily in the form of topical oil or oral compound (electuary). The majority of plant parts used in hair dyes is from the fruit and/or leaves. Natural products are highly popular and the use of plant extracts in formulations is on the rise. This is because synthetic based product may cause health hazards with several side effects. Considering the increased popularity of herbal drugs in hair care, it is worthwhile to conduct systemic investigation on the production and efficacy of these drugs. We trust that our investigation would encourage the use of traditional Iranian medicine in future hair care products.

  15. Selective Leaching of Gray Cast Iron: Electrochemical Aspects

    International Nuclear Information System (INIS)

    Na, Kyung Hwan; Yun, Eun Sub; Park, Young Sheop

    2010-01-01

    Currently, to keep step with increases in energy consumption, much attention has been paid to the construction of new nuclear power plants (NPPs) and to the continued operation of NPPs. For continued operation, the selective leaching of materials should be evaluated by visual inspections and hardness measurements as a part of One-Time Inspection Program according to the requirements of the guidelines for continued operation of pressured water reactors (PWRs) in Korea and license renewals in the United States, entitled the 'Generic Aging Lessons Learned (GALL) report.' However, the acceptance criteria for hardness have yet to be provided. Recently, USNRC released a new draft of the GALL report for comment and plans to publish its formal version by the end of 2010. In the new draft, the quantitative acceptance criteria for hardness are given at last: no more than a 20 percent decrease in hardness for gray cast iron and brass containing more than 15 percent zinc. Selective leaching is the preferential removal of one of the alloying elements from a solid alloy by corrosion processes, leaving behind a weakened spongy or porous residual structure. The materials susceptible to selective leaching include gray cast iron and brass, which are mainly used as pump casings and valve bodies in the fire protection systems of NPPs. Since selective leaching proceeds slowly during a long period of time and causes a decrease in strength without changing the overall dimensions of original material, it is difficult to identify. In the present work, the selective leaching of gray cast iron is investigated in terms of its electrochemical aspects as part of an ongoing research project to study the changes in metal properties by selective leaching

  16. The use of potassium dichromate for ultra high dose up to 120 kGy measurements in industrial irradiation process

    International Nuclear Information System (INIS)

    Conceicao, Cirilo C.S.

    2009-01-01

    The purpose of this work is the study of radiation-induced reduction of the Potassium Dichromate dosimeter in perchloric acid using modification in the composition of Dichromate dosimeter proposed by Sharpe (NPL, October 1982) to extend dose limit up to 120 kGy. This modification can allow measuring dose in process of irradiation of gem and cork directly, in these processes that the absorbed doses are very high. The dosimeter study reached linear response between 10 to 120 kGy. This dosimeter was traceable to the international metrology system, using Gammacell calibrated by Fricke reference dosimeter. The evaluation of the doses was done by spectrophotometric method. Compared to the costs using PMMA (perpex dosimeters), the use of dichromate dosimeters can reduce up to 70% of the dosimetry costs in Brazil. (author)

  17. Experimental analysis of quasi-static and dynamic fracture initiation toughness of gy4 armor steel material

    Science.gov (United States)

    Ren, Peng; Guo, Zitao

    Quasi-static and dynamic fracture initiation toughness of gy4 armour steel material are investigated using three point bend specimen. The modified split Hopkinson pressure bar (SHPB) apparatus with digital image correlation (DIC) system is applied to dynamic loading experiments. Full-field deformation measurements are obtained by using DIC to elucidate on the strain fields associated with the mechanical response. A series of experiments are conducted at different strain rate ranging from 10-3 s-1 to 103 s-1, and the loading rate on the fracture initiation toughness is investigated. Specially, the scanning electron microscope imaging technique is used to investigate the fracture failure micromechanism of fracture surfaces. The gy4 armour steel material fracture toughness is found to be sensitive to strain rate and higher for dynamic loading as compared to quasi-static loading. This work is supported by National Nature Science Foundation under Grant 51509115.

  18. Gray Matter Volumes in Patients with Chronic Fatigue Syndrome

    Directory of Open Access Journals (Sweden)

    Le-wei Tang

    2015-01-01

    Full Text Available Chronic fatigue syndrome (CFS is a debilitating and complex disorder characterized by profound fatigue with uncertain pathologic mechanism. Neuroimage may be an important key to unveil the central nervous system (CNS mechanism in CFS. Although most of the studies found gray matter (GM volumes reduced in some brain regions in CFS, there are many factors that could affect GM volumes in CFS, including chronic pain, stress, psychiatric disorder, physical activity, and insomnia, which may bias the results. In this paper, through reviewing recent literatures, we discussed these interferential factors, which overlap with the symptoms of CFS.

  19. Gray-box modelling approach for description of storage tunnel

    DEFF Research Database (Denmark)

    Harremoës, Poul; Carstensen, Jacob

    1999-01-01

    The dynamics of a storage tunnel is examined using a model based on on-line measured data and a combination of simple deterministic and black-box stochastic elements. This approach, called gray-box modeling, is a new promising methodology for giving an on-line state description of sewer systems...... of the water in the overflow structures. The capacity of a pump draining the storage tunnel is estimated for two different rain events, revealing that the pump was malfunctioning during the first rain event. The proposed modeling approach can be used in automated online surveillance and control and implemented...

  20. Initial experience of single fraction radiotherapy (8 Gy x 1) in the treatment of painful bone metastases

    International Nuclear Information System (INIS)

    Amano, Kosuke; Ikeda, Hiroko; Chigusa, Satoshi; Tanaka, Masahiro; Katayama, Hirofumi; Takeda, Koji

    2014-01-01

    Sixteen patients with painful bone metastases received single fraction radiotherapy of 8 Gy. Single fraction radiotherapy was effective in providing pain relief with response rate of 88.8%. There were no severe acute side effects. The therapeutic regimen was also safe and effective in patients with poor performance status and poor prognosis. Therefore single fraction radiotherapy should be considered to treat pain arising from bone metastases. (author)