WorldWideScience

Sample records for glands false positive

  1. Uptake of 131-I in maxillary bones mimicking salivary glands. False- positive images in patients with differentiated thyroid carcinoma (DTC )

    International Nuclear Information System (INIS)

    Degrossi, Osvaldo J.; Degrossi, E.B.; Levi de Cabrejas, Mariana

    2008-01-01

    In the whole body scans (WBS) with 131-I in the follow-up or treatment of patients bearing DTC it is observed frequently fixation areas of the tracer apparently in relation with salivary glands. These areas generally belong to the salivary glands and are present during the first 48/72 hours, but others are kept during more than 3 weeks. These latter ones were considered as possible uptake in ectopic thyroid cells in the mouth floor, iodized proteins, retention of salivary glands and other assertions. Valdivieso et al. (Cong. Arg. Biol. Med. Nuclear, 1996) and Gutierrez et al. (SLAT,Chile, 1997) considered that the fixation took place also in maxillary bones probably in areas in relation with dental illness (inflammation, pulpitis, dental caries, perionditis, periapical granuloma, periapical cyst and resorption of surrounding bone seen radiologically as periapical radiolucency). This presumption was sustained for two publications (Clin. Nucl. Med. 1998;23. 747-749, and Clin. Nucl. Med. 2000; 23; 314-315). This end the review of 638 131-I WBS carried out between January 1st, 2002 and December 31st of 2007 in 502 patients that were studied for ablation, treatment of metastasis or relapses or follow up. In 31,5% of the patients were observed areas of activity in maxilla. The intensity of concentration of the tracer was 0.3 to 1.2 % of the activity administered. In 10 patients was determinate the effective T 1/2 and in 5 a panoramic Rx of the maxilla and a bone scintigraphy with 99m-Tc-MDP; there were correlation between both images, the 131-I one an the 99m-Tc-MDP with radiology. The effective T 1/2 mean value was 6,87 days ± 0,94 (S.D.) very close to the physical T 1/2 of the radioiodine tracer indicating a strongly labeled molecule. In 6 patients treated with high activities of radioiodine (5,55 to 11,1 MBq - 150 to 300 mCi) actinic lesions were observed in mouth and lingual mucous membrane, including ulcers. The intensity of the images and of the lesions correlate

  2. False Position, Double False Position and Cramer's Rule

    Science.gov (United States)

    Boman, Eugene

    2009-01-01

    We state and prove the methods of False Position (Regula Falsa) and Double False Position (Regula Duorum Falsorum). The history of both is traced from ancient Egypt and China through the work of Fibonacci, ending with a connection between Double False Position and Cramer's Rule.

  3. The false positive exercise test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro; Matsuda, Yasuo; Ozaki, Masaharu; Ogawa, Hiroshi; Ichiyama, Masaji; Matsuda, Masako; Kusukawa, Reizo

    1986-01-01

    Exercise tests with sublingual nitroglycerin were performed on 7 patients with true positive and 8 patients with false positive exercise test results. Four of 7 patients with true positive changes and 8 patients with false positive changes underwent exercise cardiac scintigraphy. Scintigrams showed perfusion defects in 4 patients with true positive outcomes, and no perfusion defect in 8 patients with false positive outcomes. Exercise tests with sublingual nitroglycerin were performed with the same load as that without nitroglycerin. In all 7 patients with true positive exercise test results, ST segment depression observed in the control exercise test was not observed in the nitroglycerin exercise test. In the false positive patients, ST segment depression observed in the control exercise test remained unchanged in 7 of 8 patients receiving nitroglycerin. Exercise tests with sublingual nitroglycerin as well as exercise cardiac scintigraphy are valuable tods in differentiating false positive from true positive patients. Furthermore, these data suggest that ST segment depression in the false positive patients may not be related to myocardial ischemia. (author)

  4. False Positives in Exoplanet Detection

    Science.gov (United States)

    Leuquire, Jacob; Kasper, David; Jang-Condell, Hannah; Kar, Aman; Sorber, Rebecca; Suhaimi, Afiq; KELT (Kilodegree Extremely Little Telescope)

    2018-06-01

    Our team at the University of Wyoming uses a 0.6 m telescope at RBO (Red Buttes Observatory) to help confirm results on potential exoplanet candidates from low resolution, wide field surveys shared by the KELT (Kilodegree Extremely Little Telescope) team. False positives are common in this work. We carry out transit photometry, and this method comes with special types of false positives. The most common false positive seen at the confirmation level is an EB (eclipsing binary). Low resolution images are great in detecting multiple sources for photometric dips in light curves, but they lack the precision to decipher single targets at an accurate level. For example, target star KC18C030621 needed RBO’s photometric precision to determine there was a nearby EB causing exoplanet type light curves. Identifying false positives with our telescope is important work because it helps eliminate the waste of time taken by more expensive telescopes trying to rule out negative candidate stars. It also furthers the identification of other types of photometric events, like eclipsing binaries, so they can be studied on their own.

  5. False Positive and False Negative Effects on Network Attacks

    Science.gov (United States)

    Shang, Yilun

    2018-01-01

    Robustness against attacks serves as evidence for complex network structures and failure mechanisms that lie behind them. Most often, due to detection capability limitation or good disguises, attacks on networks are subject to false positives and false negatives, meaning that functional nodes may be falsely regarded as compromised by the attacker and vice versa. In this work, we initiate a study of false positive/negative effects on network robustness against three fundamental types of attack strategies, namely, random attacks (RA), localized attacks (LA), and targeted attack (TA). By developing a general mathematical framework based upon the percolation model, we investigate analytically and by numerical simulations of attack robustness with false positive/negative rate (FPR/FNR) on three benchmark models including Erdős-Rényi (ER) networks, random regular (RR) networks, and scale-free (SF) networks. We show that ER networks are equivalently robust against RA and LA only when FPR equals zero or the initial network is intact. We find several interesting crossovers in RR and SF networks when FPR is taken into consideration. By defining the cost of attack, we observe diminishing marginal attack efficiency for RA, LA, and TA. Our finding highlights the potential risk of underestimating or ignoring FPR in understanding attack robustness. The results may provide insights into ways of enhancing robustness of network architecture and improve the level of protection of critical infrastructures.

  6. An investigation of false positive dosimetry results

    International Nuclear Information System (INIS)

    Lewandowski, M.A.; Davis, S.A.; Goff, T.E.; Wu, C.F.

    1996-01-01

    The Waste Isolation Pilot Plant (WIPP) is a facility designed for the demonstration of the safe disposal of transuranic waste. Currently, the radiation source term is confined to sealed calibration and check sources since WIPP has not received waste for disposal. For several years the WIPP Dosimetry Group has operated a Harshaw Model 8800C reader to analyze Harshaw 8801-7776 thermoluminescent cards (3 TLD-700 and 1 TLD-600) with 8805 holder. The frequency of false positive results for quarterly dosimeter exchanges is higher than desired by the Dosimetry Group management. Initial observations suggested that exposure to intense ambient sunlight may be responsible for the majority of the false positive readings for element 3. A study was designed to investigate the possibility of light leaking through the holder and inducing a signal in element 3. This paper discusses the methods and results obtained, with special emphasis placed on recommendations to reduce the frequency of light-induced false positive readings

  7. False positive acetaminophen concentrations in icteric serum

    Directory of Open Access Journals (Sweden)

    L. de Jong

    2016-04-01

    Full Text Available Introduction: Serum concentrations of acetaminophen are measured to predict the risk of hepatotoxicity in cases of acetaminophen overdose and to identify acetaminophen use in patients with acute liver injury without a known cause. The acetaminophen concentration determines if treatment with N-acetyl cysteine, the antidote for acetaminophen poisoning, is warranted. Description: A 49-year-old woman was admitted to our hospital with a hepatic encephalopathy and a total serum bilirubin concentration of 442 µmol/l. The acetaminophen concentration of 11.5 mg/l was measured with an enzymatic-colorimetric assay, thus treatment with N-acetyl cysteine was started. Interestingly, the acetaminophen concentration remained unchanged (11.5–12.3 mg/l during a period of 4 consecutive days. In contrast, the acetaminophen concentration measured by HPLC, a chromatographic technique, remained undetectable Discussion: In the presented case, elevated bilirubin was the most likely candidate to interfere with acetaminophen assay causing false positive results. Bilirubin has intense absorbance in the ultraviolet and visible regions of the electromagnetic spectrum and for that reason it causes interference in an enzymatic-colorimetric assay. Conclusion: False positive acetaminophen laboratory test results may be found in icteric serum, when enzymatic-colorimetric assays are used for determination of an acetaminophen concentration. Questionable acetaminophen results in icteric serum should be confirmed by a non-enzymatic method, by means of ultrafiltration of the serum, or by dilution studies. Keywords: Acetaminophen, Enzymatic-colorimetric assays, HPLC, Bilirubin, Interference, Paracetamol, Liver failure, Jaundice

  8. Analysis of false positive and false negative cytological diagnosis of breast lesions

    International Nuclear Information System (INIS)

    Jamal, Awtif A.; Mansoor, I.

    2001-01-01

    To study the reasons for interpretive errors in false negative and false positive diagnosis of breast carcinoma on fine needle aspiration cytology material. We reviewed only those cases in which cytohistological discrepancies were found, where the cytologic material was abnormal and to some extent misinterpreted or both. There was only one false negative case (false negative fraction 0.32%) proved histologically as ductal carcinoma and four false positive cases (false positive fraction 1.2%); 2 fibroadenoma; 1 fibrocystic disease; and 1 stromal fibrosis. Smears of the two false positive fibroadenoma cases showed very high cellularity, overcrowded clusters and frequent stripped nuclei. The fibrocystic case showed tight clusters of apocrine cells and sheets of loosely aggregated macrophages that were over interpreted. Smears of the false negative ductal carcinoma was hypocellular overall, and the cells showed minimal nuclear pleomorphism. Overcrowded clusters and hypercellular smears should be carefully assessed for uniformity of cells and detailed nuclear and cytomorphological features. If the full-blown malignant cytomorphological changes are not visible, a diagnosis of suspicious or inconclusive should be made and frozen section recommended before surgery. Hypocellularity and relatively nuclear monomorphism are the reasons for failure to diagnose malignant breast lesions. Careful attention should be paid to extreme nuclear monomorphism and absence of naked bipolar cells. A cytologically atypical or suspicious diagnosis together with positive radiological and clinical findings should suggest a diagnosis of malignancy. (author)

  9. Consequences of a false-positive mammography result

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Bæksted, Christina; Vejborg, Ilse

    2016-01-01

    group used anxiolytic and antidepressant drugs. There was no difference in use of beta blockers. Hormone therapy was used more frequently by the false-positive, 36.6% versus 28.7%. The proportion of women using anxiolytic and antidepressant drugs increased with 19% from the before to the after period...... in the false-positive group, and with 16% in the normal group, resulting in an RRR of 1.02 (95% CI 0.92-1.14). RRR was 1.03 for beta blockers, 0.97 for hormone therapy. Conclusion(s): Drugs used to mitigate mood disorders were used more frequently by women with false-positive than by women with normal......Background: Previous research showed women experiencing false-positive mammograms to have greater anxiety about breast cancer than women with normal mammograms. To elucidate psychological effects of false-positive mammograms, we studied impact on drug intake.  Methods: We calculated the ratio...

  10. The problem of false positives and false negatives in violent video game experiments.

    Science.gov (United States)

    Ferguson, Christopher J

    The problem of false positives and negatives has received considerable attention in behavioral research in recent years. The current paper uses video game violence research as an example of how such issues may develop in a field. Despite decades of research, evidence on whether violent video games (VVGs) contribute to aggression in players has remained mixed. Concerns have been raised in recent years that experiments regarding VVGs may suffer from both "false positives" and "false negatives." The current paper examines this issue in three sets of video game experiments, two sets of video game experiments on aggression and prosocial behaviors identified in meta-analysis, and a third group of recent null studies. Results indicated that studies of VVGs and aggression appear to be particularly prone to false positive results. Studies of VVGs and prosocial behavior, by contrast are heterogeneous and did not demonstrate any indication of false positive results. However, their heterogeneous nature made it difficult to base solid conclusions on them. By contrast, evidence for false negatives in null studies was limited, and little evidence emerged that null studies lacked power in comparison those highlighted in past meta-analyses as evidence for effects. These results are considered in light of issues related to false positives and negatives in behavioral science more broadly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Science.gov (United States)

    Shanks, Leslie; Ritmeijer, Koert; Piriou, Erwan; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Masiga, Johnson; Abebe, Almaz

    2015-01-01

    Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL) infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals. Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs) was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367) in the VL group compared to 7.9% (200/2526) in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively). The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  12. Accounting for False Positive HIV Tests: Is Visceral Leishmaniasis Responsible?

    Directory of Open Access Journals (Sweden)

    Leslie Shanks

    Full Text Available Co-infection with HIV and visceral leishmaniasis is an important consideration in treatment of either disease in endemic areas. Diagnosis of HIV in resource-limited settings relies on rapid diagnostic tests used together in an algorithm. A limitation of the HIV diagnostic algorithm is that it is vulnerable to falsely positive reactions due to cross reactivity. It has been postulated that visceral leishmaniasis (VL infection can increase this risk of false positive HIV results. This cross sectional study compared the risk of false positive HIV results in VL patients with non-VL individuals.Participants were recruited from 2 sites in Ethiopia. The Ethiopian algorithm of a tiebreaker using 3 rapid diagnostic tests (RDTs was used to test for HIV. The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. Every RDT screen positive individual was included for testing with the gold standard along with 10% of all negatives. The final analysis included 89 VL and 405 non-VL patients. HIV prevalence was found to be 12.8% (47/ 367 in the VL group compared to 7.9% (200/2526 in the non-VL group. The RDT algorithm in the VL group yielded 47 positives, 4 false positives, and 38 negatives. The same algorithm for those without VL had 200 positives, 14 false positives, and 191 negatives. Specificity and positive predictive value for the group with VL was less than the non-VL group; however, the difference was not found to be significant (p = 0.52 and p = 0.76, respectively.The test algorithm yielded a high number of HIV false positive results. However, we were unable to demonstrate a significant difference between groups with and without VL disease. This suggests that the presence of endemic visceral leishmaniasis alone cannot account for the high number of false positive HIV results in our study.

  13. Coincidence of scintigraphic false positive and false negative findings in parathyroid and thyroid adenomas (case report)

    Energy Technology Data Exchange (ETDEWEB)

    Mana, O.; Zatta, G.; Boccolari, S.; Barbesti, S.; Tarolo, G.L.

    1987-04-01

    The subtractive double tracer scintigraphy with /sup 201/Tl and /sup 99m/Tc is a useful technique in studying parathyroid nodules; nevertheless, this method can give misleading informations especially in presence of thyroid nodules with false positive and false negative findings. In this case report the technique was applied in studying a patient with three nodules (two thyroid adenomas and one parathyroid adenoma), where both scintigraphic and echographic methods provided misleading informations. The selective uptake of /sup 201/Tl in the upper region of the right thyroid lobe gave a false positive finding, while the increased uptake of /sup 99m/Tc in a hyperfunctioning thyroid adenoma of left lobe masked the parathyroid adenoma laying below, giving a false negative finding.

  14. Epidemiology, public health, and the rhetoric of false positives

    DEFF Research Database (Denmark)

    Blair, Aaron; Saracci, Rodolfo; Vineis, Paolo

    2009-01-01

    BACKGROUND: As an observational science, epidemiology is regarded by some researchers as inherently flawed and open to false results. In a recent paper, Boffetta et al. [Boffetta P, McLaughlin JK, LaVecchia C, Tarone RE, Lipworth L, Blot WJ. False-positive results in cancer epidemiology: a plea f...

  15. False-positive 111In-pentetreotide Uptake in Gastritis

    International Nuclear Information System (INIS)

    Usmani, Sharjeel; Alshammari, Alshaima

    2013-01-01

    111 In-pentetreotide [ 111 In-octreoscan] is the most widely used radiolabeled somatostatin analog for evaluating neuroendocrine tumor overexpression of somatostatin receptors. False-positives studies of somatostatin receptor scintigraphy have been reported and often the cause is unexplained but assumed to be due to high number of somatostatin receptors in other pathologies. Causes of false-positives include visualization of the gallbladder, nasal mucosa and pulmonary hilar areas in respiratory infections, thyroid abnormalities, accessory spleens, recent Cerebrovascular accidents (CVA's) and activity at the site of a recent surgical incision. In infection or inflammation the cause of false-positive uptake is probably the result of tracer binding by somatostatin receptors on the inflammatory leukocytes. In this case report, we report, a 44-year-old male patient with false-positive 111 In-pentetreotide uptake due to gastritis

  16. Characterisation of false-positive observations in botanical surveys

    Directory of Open Access Journals (Sweden)

    Quentin J. Groom

    2017-05-01

    Full Text Available Errors in botanical surveying are a common problem. The presence of a species is easily overlooked, leading to false-absences; while misidentifications and other mistakes lead to false-positive observations. While it is common knowledge that these errors occur, there are few data that can be used to quantify and describe these errors. Here we characterise false-positive errors for a controlled set of surveys conducted as part of a field identification test of botanical skill. Surveys were conducted at sites with a verified list of vascular plant species. The candidates were asked to list all the species they could identify in a defined botanically rich area. They were told beforehand that their final score would be the sum of the correct species they listed, but false-positive errors counted against their overall grade. The number of errors varied considerably between people, some people create a high proportion of false-positive errors, but these are scattered across all skill levels. Therefore, a person’s ability to correctly identify a large number of species is not a safeguard against the generation of false-positive errors. There was no phylogenetic pattern to falsely observed species; however, rare species are more likely to be false-positive as are species from species rich genera. Raising the threshold for the acceptance of an observation reduced false-positive observations dramatically, but at the expense of more false negative errors. False-positive errors are higher in field surveying of plants than many people may appreciate. Greater stringency is required before accepting species as present at a site, particularly for rare species. Combining multiple surveys resolves the problem, but requires a considerable increase in effort to achieve the same sensitivity as a single survey. Therefore, other methods should be used to raise the threshold for the acceptance of a species. For example, digital data input systems that can verify

  17. Trastuzumab for HER-2-Positive Advanced Salivary Gland Cancer

    Directory of Open Access Journals (Sweden)

    Yi-Tsung Yang

    2014-12-01

    Full Text Available Salivary gland adenocarcinoma is a rare type of head and neck cancer and often has aggressive behavior with propensity to recur and metastasize. Currently, there are no standard treatment guidelines. Surgery is however, the mainstay of treatment in resectable disease and radiation is also considered for most patients after surgery. Systemic chemotherapy is reserved for metastatic cases, but its results are often disappointing. Recent development of molecular biology has shown that salivary gland caner has several molecular changes which may guide potential therapeutic targets. Here, we report a 67 year-old man diagnosed to have metastasized minor salivary gland adenocarcinoma with diffuse human epidermal growth factor receptor-2 (HER-2-positive, by the immunohistochemical (IHC stain. He was treated with a trastuzumab-containing chemotherapeutic regimen with encouraging results.

  18. False positive and false negative FDG-PET scans in various thoracic diseases

    International Nuclear Information System (INIS)

    Chang, Jung Min; Lee, Hyun Ju; Goo, Jin Mo; Lee, Ho Young; Lee, Jong Jin; Chung, June Key; Im, Jung Gi

    2006-01-01

    Fluorodeoxygucose (FDG)-positron emission tomography (PET) is being used more and more to differentiate benign form malignant focal lesions and it has been shown to be more efficacious than conventional chest computed tomography (CT). However, FDG is not a cancer-specific agent, and false positive findings in benign diseases have been reported. Infectious diseases (mycobacterial, fungal, bacterial infection), sarcoidosis, radiation pneumonitis and post-operative surgical conditions have shown intense uptake on PET scan. On the other hand, tumors with low glycolytic activity such as adenomas, bronchioloalveolar carcinomas, carcinoid tumors, low grade lymphomas and small sized tumors have revealed false negative findings on PET scan, Furthermore, in diseases located near the physiologic uptake sites (heart, bladder, kidney, and liver), FDG-PET should be complemented with other imaging modalities to confirm results and to minimize false negative findings. Familiarity with these false positive and negative findings will help radiologists interpret PET scans more accurately and also will help to determine the significance of the findings. In this review, we illustrate false positive and negative findings of PET scan in a variety of diseases

  19. Female False Positive Exercise Stress ECG Testing - Fact Verses Fiction.

    Science.gov (United States)

    Fitzgerald, Benjamin T; Scalia, William M; Scalia, Gregory M

    2018-03-07

    Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard. Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test. Three thousand consecutive negative stress echocardiograms (1036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1036, 18.7%) and males (371/1964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (preinforce the value of stress imaging, particularly in women. Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

  20. Implications of false-positive results for future cancer screenings.

    Science.gov (United States)

    Taksler, Glen B; Keating, Nancy L; Rothberg, Michael B

    2018-06-01

    False-positive cancer screening results may affect a patient's willingness to obtain future screening. The authors conducted logistic regression analysis of 450,484 person-years of electronic medical records (2006-2015) in 92,405 individuals aged 50 to 75 years. Exposures were false-positive breast, prostate, or colorectal cancer screening test results (repeat breast imaging or negative breast biopsy ≤3 months after screening mammography, repeat prostate-specific antigen [PSA] test ≤3 months after PSA test result ≥4.0 ng/mL or negative prostate biopsy ≤3 months after any PSA result, or negative colonoscopy [without biopsy/polypectomy] ≤6 months after a positive fecal occult blood test). Outcomes were up-to-date status with breast or colorectal cancer screening. Covariates included prior screening history, clinical information (eg, family history, obesity, and smoking status), comorbidity, and demographics. Women were more likely to be up to date with breast cancer screening if they previously had false-positive mammography findings (adjusted odds ratio [AOR], 1.43 [95% confidence interval, 1.34-1.51] without breast biopsy and AOR, 2.02 [95% confidence interval, 1.56-2.62] with breast biopsy; both Pfalse-positive PSA testing were more likely to be up to date with colorectal cancer screening (AOR, 1.22 [P = .039] without prostate imaging/biopsy and AOR, 1.60 [P = .028] with imaging/biopsy). Results were stronger for individuals with more false-positive results (all P≤.005). However, women with previous false-positive colorectal cancer fecal occult blood test screening results were found to be less likely to be up to date with breast cancer screening (AOR, 0.73; Pfalse-positive breast or prostate cancer screening test were more likely to engage in future screening. Cancer 2018;124:2390-8. © 2018 American Cancer Society. © 2018 American Cancer Society.

  1. 'False-positive' and 'false-negative' test results in clinical urine drug testing.

    Science.gov (United States)

    Reisfield, Gary M; Goldberger, Bruce A; Bertholf, Roger L

    2009-08-01

    The terms 'false-positive' and 'false-negative' are widely used in discussions of urine drug test (UDT) results. These terms are inadequate because they are used in different ways by physicians and laboratory professionals and they are too narrow to encompass the larger universe of potentially misleading, inappropriate and unexpected drug test results. This larger universe, while not solely comprised of technically 'true' or 'false' positive or negative test results, presents comparable interpretive challenges with corresponding clinical implications. In this review, we propose the terms 'potentially inappropriate' positive or negative test results in reference to UDT results that are ambiguous or unexpected and subject to misinterpretation. Causes of potentially inappropriate positive UDT results include in vivo metabolic conversions of a drug, exposure to nonillicit sources of a drug and laboratory error. Causes of potentially inappropriate negative UDT results include limited assay specificity, absence of drug in the urine, presence of drug in the urine, but below established assay cutoff, specimen manipulation and laboratory error. Clinical UDT interpretation is a complicated task requiring knowledge of recent prescription, over-the-counter and herbal drug administration, drug metabolism and analytical sensitivities and specificities.

  2. Diagnosing periprosthetic infection: false-positive intraoperative Gram stains.

    Science.gov (United States)

    Oethinger, Margret; Warner, Debra K; Schindler, Susan A; Kobayashi, Hideo; Bauer, Thomas W

    2011-04-01

    Intraoperative Gram stains have a reported low sensitivity but high specificity when used to help diagnose periprosthetic infections. In early 2008, we recognized an unexpectedly high frequency of apparent false-positive Gram stains from revision arthroplasties. The purpose of this report is to describe the cause of these false-positive test results. We calculated the sensitivity and specificity of all intraoperative Gram stains submitted from revision arthroplasty cases during a 3-month interval using microbiologic cultures of the same samples as the gold standard. Methods of specimen harvesting, handling, transport, distribution, specimen processing including tissue grinding/macerating, Gram staining, and interpretation were studied. After a test modification, results of specimens were prospectively collected for a second 3-month interval, and the sensitivity and specificity of intraoperative Gram stains were calculated. The retrospective review of 269 Gram stains submitted from revision arthroplasties indicated historic sensitivity and specificity values of 23% and 92%, respectively. Systematic analysis of all steps of the procedure identified Gram-stained but nonviable bacteria in commercial broth reagents used as diluents for maceration of periprosthetic membranes before Gram staining and culture. Polymerase chain reaction and sequencing showed mixed bacterial DNA. Evaluation of 390 specimens after initiating standardized Millipore filtering of diluent fluid revealed a reduced number of positive Gram stains, yielding 9% sensitivity and 99% specificity. Clusters of false-positive Gram stains have been reported in other clinical conditions. They are apparently rare related to diagnosing periprosthetic infections but have severe consequences if used to guide treatment. Even occasional false-positive Gram stains should prompt review of laboratory methods. Our observations implicate dead bacteria in microbiologic reagents as potential sources of false-positive Gram

  3. Diagnostic Invasiveness and Psychosocial Consequences of False-Positive Mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert Dirk; Brodersen, John

    2015-01-01

    PURPOSE: We undertook a study to assess whether women with false-positivemammography have worse psychosocial consequences if managed with aworkup that involves a biopsy (invasive group) than if managed with only additional imaging (noninvasive group). METHODS: We performed subgroup analysis...... of a cohort study of 454 womenwith abnormal screening mammography and 908 matched control women withnormal results. Using a condition-specific questionnaire (Consequences of Screening in Breast Cancer), we assessed 12 psychosocial consequences at 5 time points (0, 1, 6, 18, and 36 months after final diagnosis......) and compared the 2 groups of women with false-positives (invasive and noninvasive management groups). RESULTS: Among the 252 women with false-positive mammography eligible forthis study, psychosocial consequences were similar for those managed invasivelyand those managed noninvasively during the 36 months...

  4. False-positive results in pharmacoepidemiology and pharmacovigilance.

    Science.gov (United States)

    Bezin, Julien; Bosco-Levy, Pauline; Pariente, Antoine

    2017-09-01

    False-positive constitute an important issue in scientific research. In the domain of drug evaluation, it affects all phases of drug development and assessment, from the very early preclinical studies to the late post-marketing evaluations. The core concern associated with this false-positive is the lack of replicability of the results. Aside from fraud or misconducts, false-positive is often envisioned from the statistical angle, which considers them as a price to pay for type I error in statistical testing, and its inflation in the context of multiple testing. If envisioning this problematic in the context of pharmacoepidemiology and pharmacovigilance however, that both evaluate drugs in an observational settings, information brought by statistical testing and the significance of such should only be considered as additional to the estimates provided and their confidence interval, in a context where differences have to be a clinically meaningful upon everything, and the results appear robust to the biases likely to have affected the studies. In the following article, we consequently illustrate these biases and their consequences in generating false-positive results, through studies and associations between drug use and health outcomes that have been widely disputed. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  5. APHRODITE: an Anomaly-based Architecture for False Positive Reduction

    NARCIS (Netherlands)

    Bolzoni, D.; Etalle, Sandro

    We present APHRODITE, an architecture designed to reduce false positives in network intrusion detection systems. APHRODITE works by detecting anomalies in the output traffic, and by correlating them with the alerts raised by the NIDS working on the input traffic. Benchmarks show a substantial

  6. A Demonstration of Regression False Positive Selection in Data Mining

    Science.gov (United States)

    Pinder, Jonathan P.

    2014-01-01

    Business analytics courses, such as marketing research, data mining, forecasting, and advanced financial modeling, have substantial predictive modeling components. The predictive modeling in these courses requires students to estimate and test many linear regressions. As a result, false positive variable selection ("type I errors") is…

  7. False-positive Human Papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Lynge, Elsebeth

    2011-01-01

    Based on data from randomised controlled trials (RCT) on primary cervical screening, it has been reported that the problem of more frequent false-positive tests in Human Papillomavirus (HPV) DNA screening compared to cytology could be overcome. However, these reports predominantly operated...

  8. Evaluation of false positivity and cross reactivity in the investigation ...

    African Journals Online (AJOL)

    This study evaluated the causes of false positive Human Immunodeficiency Virus test results (F+HIV), cross reactivity of HIV antibodies with other non HIV antibodies, and efficiency of the serial and parallel testing algorithms. 100 blood samples randomly collected from clients attending the Heart to Heart HIV counseling and ...

  9. Detecting false positive sequence homology: a machine learning approach.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Bybee, Seth M

    2016-02-24

    Accurate detection of homologous relationships of biological sequences (DNA or amino acid) amongst organisms is an important and often difficult task that is essential to various evolutionary studies, ranging from building phylogenies to predicting functional gene annotations. There are many existing heuristic tools, most commonly based on bidirectional BLAST searches that are used to identify homologous genes and combine them into two fundamentally distinct classes: orthologs and paralogs. Due to only using heuristic filtering based on significance score cutoffs and having no cluster post-processing tools available, these methods can often produce multiple clusters constituting unrelated (non-homologous) sequences. Therefore sequencing data extracted from incomplete genome/transcriptome assemblies originated from low coverage sequencing or produced by de novo processes without a reference genome are susceptible to high false positive rates of homology detection. In this paper we develop biologically informative features that can be extracted from multiple sequence alignments of putative homologous genes (orthologs and paralogs) and further utilized in context of guided experimentation to verify false positive outcomes. We demonstrate that our machine learning method trained on both known homology clusters obtained from OrthoDB and randomly generated sequence alignments (non-homologs), successfully determines apparent false positives inferred by heuristic algorithms especially among proteomes recovered from low-coverage RNA-seq data. Almost ~42 % and ~25 % of predicted putative homologies by InParanoid and HaMStR respectively were classified as false positives on experimental data set. Our process increases the quality of output from other clustering algorithms by providing a novel post-processing method that is both fast and efficient at removing low quality clusters of putative homologous genes recovered by heuristic-based approaches.

  10. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  11. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives

    NARCIS (Netherlands)

    Wolf, M.; Kurvers, R.H.J.M.; Ward, A.J.W.; Krause, S.; Krause, J.

    2013-01-01

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives;

  12. When are false-positive and false-negative 18F'FDG PET scans really false?

    International Nuclear Information System (INIS)

    Binns, D.S.; Hicks, R.J.; Fawcett, M.E.

    1999-01-01

    Full text: A 61-year-old male presented with locally advanced squamous cell carcinoma of the base of tongue. In the absence of wider metastatic disease on conventional staging, he was enrolled in a phase I, dose escalation chemoradiotherapy trial. In this study, therapeutic response to radiotherapy combined with cisplatin and a chemotherapeutic agent which specifically targets hypoxic cells (tirapazamine) was evaluated with serial 18 F-FDG PET scans. Baseline 18 F-FDG PET confirmed locally advanced disease, although a previously undetected lower cervical lymph node was identified and included in the radiotherapy portal. Whole-body PET revealed a small metabolically active area adjacent to the right hemidiaphragm. Respiratory gated, high-resolution helical CT failed to find structural evidence of disease and, as a result, the patient was enrolled in the 7 week therapy regime on the assumption that the PET finding was a false-positive result. Repeat 18 F-FDG PET scans at the middle, end and 12 weeks post-treatment showed excellent therapeutic response in the head and neck which was discordant with clinical and CT findings, and resolution of the metabolically active chest lesion. Despite the negative PET scan, persistent clinical and CT evidence of a residual tumour mass suggested a false-negative result and resulted in a neck lymph node dissection. This showed no evidence of malignant cells. Five months following treatment, the patient presented with pleural effusion at the base on the right lung. Subsequent CT scanning showed a small pleural lesion at the site of initial 18 F-FDG uptake. Biopsy confirmed metastatic disease. The apparent transient resolution of 18 F-FDG uptake in the pleural lesion with treatment presumably reflected a combination of reduced metabolic activity and size due to the partial, but not complete, cytotoxic effects of cisplatin. In conclusion, this case emphasizes the importance of pathological review and clinical follow-up in reconciling

  13. Adrenocortical Carcinoma: False Positive in an I-123 Metaiodobenzylguanidine Scan

    Energy Technology Data Exchange (ETDEWEB)

    Rey, Cristina Rodriguez; Candil, Aida Ortega; Galvan, Eliseo Vano; Martin, Maria Nieves Cabrera; Delgado, Jose Luis Carreras [Clinico San Carlos Hospital, Madrid (Spain)

    2016-06-15

    A 55-year-old man with a personal his history of left pheochromocytoma 2 years previously presented with an abdominal ultrasound showed a large left upper quadrant solid mass (calipers), with heterogeneous echogenicity and central cystic degeneration areas or necrosis. F-18 Fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT was performed as ACC was suspected. ACC is an uncommon malignant neoplasm of unknown cause; however, smoking and oral contraceptives may be risk factors. Patients usually present with advanced-stage disease and have poor prognosis, with a 2-year recurrence rate that ranges form 73 to 86 %. An MIBG scan was performed after injection of 185 MBq of I-123 MIBG intravenously. Single photon emission tomography (SPECT)/CT scan showed abnormal isotope accumulation in the tumor region. The patient underwent total resection of the tumor. The histology was of ACC, with areas of necrosis and cystic areas, so the result of the MIBG scan was a false positive. Authors divided false-positive MIBG studies into three categories. The first category is neuroendocrine lesions other than pheochromocytomas (tumors of the APUD series). the second category consists in adrenal lesions other than pheochromocytomas (adenomas, ACC) the reasons for this abnormal uptake are unclear. The third category consists of tracer uptake adjacent to the adrenal due to abnormalities in the route of excretion.

  14. THE XO PLANETARY SURVEY PROJECT: ASTROPHYSICAL FALSE POSITIVES

    International Nuclear Information System (INIS)

    Poleski, Radosaw; McCullough, Peter R.; Valenti, Jeff A.; Burke, Christopher J.; Machalek, Pavel; Janes, Kenneth

    2010-01-01

    Searches for planetary transits find many astrophysical false positives as a by-product. There are four main types analyzed in the literature: a grazing-incidence eclipsing binary (EB) star, an EB star with a small radius companion star, a blend of one or more stars with an unrelated EB star, and a physical triple star system. We present a list of 69 astrophysical false positives that had been identified as candidates of transiting planets of the on-going XO survey. This list may be useful in order to avoid redundant observation and characterization of these particular candidates that have been independently identified by other wide-field searches for transiting planets. The list may be useful for those modeling the yield of the XO survey and surveys similar to it. Subsequent observations of some of the listed stars may improve mass-radius relations, especially for low-mass stars. From the candidates exhibiting eclipses, we report three new spectroscopic double-line binaries and give mass function estimations for 15 single-line spectroscopic binaries.

  15. False positive paediatric labelled white blood cell study

    International Nuclear Information System (INIS)

    Beveridge, N.; Bennett, E.; Thomas, P.

    2002-01-01

    Full text: An eight-month-old female presented for a technetium labelled white blood cell study (LWBC) to exclude an intra-abdominal abscess. Born premature, the child had surgery to repair a perforated bowel and had repeated presentations with diarrhoea, fevers, a tender right upper quadrant and a raised leucocyte count. Multiple imaging modalities failed to demonstrate recurrent bowel perforation, ischaemia or an intra-abdominal mass. A LWBC study was performed with whole body imaging at 1 and 5 hours post re-injection of the radiolabelled blood. No abnormal uptake was visualised in the abdomen but abnormal white cell accumulation was noted in the right hind foot and the length of the right lower leg. This activity appeared to lie along the course of the right tibia. Plain X-ray demonstrated no evidence of tibial osteomyelitis. Concern that the LWBC may be falsely negative in a patient on antibiotics, a gallium scan was immediately performed to re-examine the abdomen. The whole body gallium images demonstrated normal physiological uptake in the abdomen and no evidence of infection in the right leg. The patient had no clinical features to support right leg pathology. The abnormal LWBC localisation in the right lower leg/foot was therefore falsely positive. The most likely explanation is increased activation of the autologous LWBC by 'rough' handling during difficult venesection and re-injection through small veins and needles/cannulas. The slow flow through the veins draining the foot injection site would contribute to margination in these vessel walls. This is a potential cause for false positive LWBC studies- with significant implications for patient care. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  16. Protein complex prediction via dense subgraphs and false positive analysis.

    Directory of Open Access Journals (Sweden)

    Cecilia Hernandez

    Full Text Available Many proteins work together with others in groups called complexes in order to achieve a specific function. Discovering protein complexes is important for understanding biological processes and predict protein functions in living organisms. Large-scale and throughput techniques have made possible to compile protein-protein interaction networks (PPI networks, which have been used in several computational approaches for detecting protein complexes. Those predictions might guide future biologic experimental research. Some approaches are topology-based, where highly connected proteins are predicted to be complexes; some propose different clustering algorithms using partitioning, overlaps among clusters for networks modeled with unweighted or weighted graphs; and others use density of clusters and information based on protein functionality. However, some schemes still require much processing time or the quality of their results can be improved. Furthermore, most of the results obtained with computational tools are not accompanied by an analysis of false positives. We propose an effective and efficient mining algorithm for discovering highly connected subgraphs, which is our base for defining protein complexes. Our representation is based on transforming the PPI network into a directed acyclic graph that reduces the number of represented edges and the search space for discovering subgraphs. Our approach considers weighted and unweighted PPI networks. We compare our best alternative using PPI networks from Saccharomyces cerevisiae (yeast and Homo sapiens (human with state-of-the-art approaches in terms of clustering, biological metrics and execution times, as well as three gold standards for yeast and two for human. Furthermore, we analyze false positive predicted complexes searching the PDBe (Protein Data Bank in Europe database in order to identify matching protein complexes that have been purified and structurally characterized. Our analysis shows

  17. Accurate decisions in an uncertain world: collective cognition increases true positives while decreasing false positives.

    Science.gov (United States)

    Wolf, Max; Kurvers, Ralf H J M; Ward, Ashley J W; Krause, Stefan; Krause, Jens

    2013-04-07

    In a wide range of contexts, including predator avoidance, medical decision-making and security screening, decision accuracy is fundamentally constrained by the trade-off between true and false positives. Increased true positives are possible only at the cost of increased false positives; conversely, decreased false positives are associated with decreased true positives. We use an integrated theoretical and experimental approach to show that a group of decision-makers can overcome this basic limitation. Using a mathematical model, we show that a simple quorum decision rule enables individuals in groups to simultaneously increase true positives and decrease false positives. The results from a predator-detection experiment that we performed with humans are in line with these predictions: (i) after observing the choices of the other group members, individuals both increase true positives and decrease false positives, (ii) this effect gets stronger as group size increases, (iii) individuals use a quorum threshold set between the average true- and false-positive rates of the other group members, and (iv) individuals adjust their quorum adaptively to the performance of the group. Our results have broad implications for our understanding of the ecology and evolution of group-living animals and lend themselves for applications in the human domain such as the design of improved screening methods in medical, forensic, security and business applications.

  18. The OGCleaner: filtering false-positive homology clusters.

    Science.gov (United States)

    Fujimoto, M Stanley; Suvorov, Anton; Jensen, Nicholas O; Clement, Mark J; Snell, Quinn; Bybee, Seth M

    2017-01-01

    Detecting homologous sequences in organisms is an essential step in protein structure and function prediction, gene annotation and phylogenetic tree construction. Heuristic methods are often employed for quality control of putative homology clusters. These heuristics, however, usually only apply to pairwise sequence comparison and do not examine clusters as a whole. We present the Orthology Group Cleaner (the OGCleaner), a tool designed for filtering putative orthology groups as homology or non-homology clusters by considering all sequences in a cluster. The OGCleaner relies on high-quality orthologous groups identified in OrthoDB to train machine learning algorithms that are able to distinguish between true-positive and false-positive homology groups. This package aims to improve the quality of phylogenetic tree construction especially in instances of lower-quality transcriptome assemblies. https://github.com/byucsl/ogcleaner CONTACT: sfujimoto@gmail.comSupplementary information: Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  19. Reduction of lymph tissue false positives in pulmonary embolism detection

    Science.gov (United States)

    Ghanem, Bernard; Liang, Jianming; Bi, Jinbo; Salganicoff, Marcos; Krishnan, Arun

    2008-03-01

    Pulmonary embolism (PE) is a serious medical condition, characterized by the partial/complete blockage of an artery within the lungs. We have previously developed a fast yet effective approach for computer aided detection of PE in computed topographic pulmonary angiography (CTPA),1 which is capable of detecting both acute and chronic PEs, achieving a benchmark performance of 78% sensitivity at 4 false positives (FPs) per volume. By reviewing the FPs generated by this system, we found the most dominant type of FP, roughly one third of all FPs, to be lymph/connective tissue. In this paper, we propose a novel approach that specifically aims at reducing this FP type. Our idea is to explicitly exploit the anatomical context configuration of PE and lymph tissue in the lungs: a lymph FP connects to the airway and is located outside the artery, while a true PE should not connect to the airway and must be inside the artery. To realize this idea, given a detected candidate (i.e. a cluster of suspicious voxels), we compute a set of contextual features, including its distance to the airway based on local distance transform and its relative position to the artery based on fast tensor voting and Hessian "vesselness" scores. Our tests on unseen cases show that these features can reduce the lymph FPs by 59%, while improving the overall sensitivity by 3.4%.

  20. False-positive head-impulse test in cerebellar ataxia

    Directory of Open Access Journals (Sweden)

    Olympia eKremmyda

    2012-11-01

    Full Text Available Abstract:The objective of this study was to compare the findings of the bedside head impulse test (HIT, passive head rotation gain, and caloric irrigation in patients with cerebellar ataxia (CA. In 16 patients with CA and bilaterally pathological bedside HIT, VOR gains were measured during HIT and passive head rotation by scleral search coil technique. Eight of the patients had pathologically reduced caloric responsiveness, while the other eight had normal caloric responses. Those with normal calorics showed a slightly reduced HIT gain (mean±SD: 0.73±0.15. In those with pathological calorics, gains 80ms and 100 ms after the HIT as well as the passive rotation VOR gains were significantly lower. The corrective saccade after head turn occurred earlier in patients with pathological calorics (111±62 ms after onset of the HIT than in those with normal calorics. (191±17 ms, p=0.0064 We indentified two groups of patients with CA: those with an isolated moderate HIT deficit only, probably due to floccular dysfunction, and those with combined HIT, passive rotation and caloric deficit, probably due to a peripheral vestibular deficit. From a clinical point of view, these results show that the bedside HIT alone can be false positive for establishing a diagnosis of a bilateral peripheral vestibular deficit in patients with CA.

  1. Benign oral pathology as a cause of false positive 131I uptake in thyroid carcinoma

    International Nuclear Information System (INIS)

    Mansberg, R.; Wadhwa, S.S.; Fernandes, V.B.

    1997-01-01

    Full text: We present three thyroidectomised patients with a history of thyroid carcinoma who had non-metastatic 131 I uptake due to benign oral pathology. A salivary gland study suggested impaired function but no obstruction was demonstrated on a sialogram. The symptoms resolved on antibiotic therapy and a subsequent 131 I study was normal. A subsequent thallium study demonstrated physiological tracer distribution. A 35-year-old female with papillary cell carcinoma of the thyroid demonstrated a focus of uptake on the right hemi-mandible following both a diagnostic and a therapeutic dose of 131 I. This area was tender and an OPG confirmed an area of liquefaction at this site. A 53-year-old female with medullary cell carcinoma of the thyroid demonstrated a focus of uptake in the right side of the maxilla following a diagnostic administration of 131 I. An OPG confirmed an area of liquefaction around the apex of the right upper centre. These three cases illustrate salivary gland and dental inflammation as causes of false positive 131 I uptake. It is important to differentiate non-metastatic 131 I uptake from that due to functioning metastatic thyroid carcinoma in order to avoid inappropriate treatment with large additional doses of 131 I. As in these patients, clinical assessment and the use of anatomical imaging or other isotopes such as thallium or technetium can be helpful in ruling out a mistaken diagnosis of metastasis

  2. False Positive Radioiodinated Metaiodobenzylguanidine (123I-MIBG Uptake in Undifferentiated Adrenal Malignant Tumor

    Directory of Open Access Journals (Sweden)

    Hee Soo Jung

    2015-01-01

    Full Text Available 123I-Metaiodobenzylguanidine (123I-MIBG scintigraphy is a widely used functional imaging tool with a high degree of sensitivity and specificity in diagnosis of pheochromocytoma. However, rare cases of false positive reactions have been reported. A 67-year-old male patient was admitted with epigastric pain. Abdominal computed tomography (CT revealed a heterogeneous left adrenal mass 6 cm in diameter; following hormone testing, 123I-MIBG scintigraphy was performed to determine the presence of pheochromocytoma, which confirmed eccentric uptake by a large left adrenal gland mass. Chest CT and PET-CT confirmed metastatic lymphadenopathy; therefore, endobronchial ultrasound transbronchial needle aspiration was performed. Metastatic carcinoma of unknown origin was suspected from a lymph node biopsy, and surgical resection was performed for definitive diagnosis and correction of excess hormonal secretion. A final diagnosis of undifferentiated adrenal malignant tumor was rendered, instead of histologically malignant pheochromocytoma, despite the uptake of 123I-MIBG demonstrated by scintigraphy.

  3. False positive localisation of C-11 methionine in a colloid nodule

    International Nuclear Information System (INIS)

    Mahajan, Sonia; Tripathi, Madhavi; Jaimini, Abhinav; Dinesh, Anant

    2011-01-01

    A 45-year-old female diagnosed with carcinoma of the left breast on histopathological examination underwent both 18 F-flourodeoxyglucose (FDG) and 11C-methionine (MET) positron emission tomography/computed tomography (PET/CT) as part of a protocol comparing the utility of these tracers for predicting a response to neoadjuvant chemotherapy in breast carcinoma. Abnormal FDG and MET accumulation was noted in the left breast primary, left axillary lymph nodes, and also in a well-defined nodule present in the left lobe of the thyroid gland. Keeping in mind the possibility of thyroid neoplasm/metastasis, the patient was referred for fine needle aspiration cytology (FNAC) from the thyroid nodule that revealed features of a simple colloid nodule. Focal thyroid lesions incidentally found on 18 F-FDG PET/CT have a high risk of thyroid malignancy. Non-specific accumulation of FDG in thyroid adenomas is also known. This case highlights a potential cause for false positive on C-11 MET PET/CT in colloid adenomas, which should be kept in mind while using this tracer for oncological indications

  4. Risk of breast cancer after false-positive test results in screening mammography

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My Catarina; Risør, Louise Madeleine; Thorsted, Brian Larsen

    2012-01-01

    Screening for disease in healthy people inevitably leads to some false-positive tests in disease-free individuals. Normally, women with false-positive screening tests for breast cancer are referred back to routine screening. However, the long-term outcome for women with false-positive tests...

  5. Memory for media: investigation of false memories for negatively and positively charged public events.

    Science.gov (United States)

    Porter, Stephen; Taylor, Kristian; Ten Brinke, Leanne

    2008-01-01

    Despite a large body of false memory research, little has addressed the potential influence of an event's emotional content on susceptibility to false recollections. The Paradoxical Negative Emotion (PNE) hypothesis predicts that negative emotion generally facilitates memory but also heightens susceptibility to false memories. Participants were asked whether they could recall 20 "widely publicised" public events (half fictitious) ranging in emotional valence, with or without visual cues. Participants recalled a greater number of true negative events (M=3.31/5) than true positive (M=2.61/5) events. Nearly everyone (95%) came to recall at least one false event (M=2.15 false events recalled). Further, more than twice as many participants recalled any false negative (90%) compared to false positive (41.7%) events. Negative events, in general, were associated with more detailed memories and false negative event memories were more detailed than false positive event memories. Higher dissociation scores were associated with false recollections of negative events, specifically.

  6. Look Again: An Investigation of False Positive Detections in Combat Models

    National Research Council Canada - National Science Library

    Wainwright, Ryan K

    2008-01-01

    .... Existing combat models tend to overlook or downplay false positive detections. Signal Detection Theory provides the framework for analysis of an observer's hits, misses, correct rejections, and false alarms...

  7. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  8. The risk factor of false-negative and false-positive for T-SPOT.TB in active tuberculosis.

    Science.gov (United States)

    Di, Li; Li, Yan

    2018-02-01

    T-SPOT.TB is a promising diagnosis tool to identify both pulmonary tuberculosis and extrapulmonary tuberculosis, as well as latent tuberculosis; however, the factors that affect the results of T-SPOT.TB remains unclear. In this study, we aim to figure out the risk factor of T-SPOT.TB for active TB. A total of 349 patients were recruited between January 1st, 2016 and January 22st, 2017 at Renmin Hospital of Wuhan University, including 98 subjects with TB and 251 subjects with non-TB disease, and received T-SPOT.TB (Oxford Immunotec Ltd). Statistics were analyzed by SPSS 19.0 using logistic regression. The overall specificity and sensitivity of the T-SPOT.TB was 92.83% (233/251; 95%CI 0.8872-0.9557) and 83.67% (82/98; 95%CI 0.7454-0.9010), respectively. Patients with tuberculous meningitis were more likely to have false-negative results (OR 17.4, 95%CI 3.068-98.671; P.05). Tuberculous meningitis was a risk factor of false-negative for T-SPOT.TB, while cured TB was a risk factor of false-positive. © 2017 Wiley Periodicals, Inc.

  9. Generating false negatives and false positives for As and Mo concentrations in groundwater due to well installation.

    Science.gov (United States)

    Wallis, Ilka; Pichler, Thomas

    2018-08-01

    Groundwater monitoring relies on the acquisition of 'representative' groundwater samples, which should reflect the ambient water quality at a given location. However, drilling of a monitoring well for sample acquisition has the potential to perturb groundwater conditions to a point that may prove to be detrimental to the monitoring objective. Following installation of 20 monitoring wells in close geographic proximity in central Florida, opposing concentration trends for As and Mo were observed. In the first year after well installation As and Mo concentrations increased in some wells by a factor of 2, while in others As and Mo concentrations decreased by a factor of up to 100. Given this relatively short period of time, a natural change in groundwater composition of such magnitude is not expected, leaving well installation itself as the likely cause for the observed concentration changes. Hence, initial concentrations were identified as 'false negatives' if concentrations increased with time or as 'false positives' if concentrations decreased. False negatives were observed if concentrations were already high, i.e., the As or Mo were present at the time of drilling. False positives were observed if concentrations were relatively lower, i.e., As or Mo were present at low concentrations of approximately 1 to 2μg/L before drilling, but then released from the aquifer matrix as a result of drilling. Generally, As and Mo were present in the aquifer matrix in either pyrite or organic matter, both of which are susceptible to dissolution if redox conditions change due to the addition of oxygen. Thus, introduction of an oxidant into an anoxic aquifer through use of an oxygen saturated drilling fluid served as the conceptual model for the trends where concentrations decreased with time. Mixing between drilling fluid and groundwater (i.e., dilution) was used as the conceptual model for scenarios where increasing trends were observed. Conceptual models were successfully tested

  10. Addressing False Positives in Early Reading Assessment Using Intervention Response Data

    Science.gov (United States)

    McAlenney, Athena Lentini; Coyne, Michael D.

    2015-01-01

    The current study examined a solution to high false positive reading risk classification rates in early kindergarten by investigating a method of identifying students with possible false positive risk classifications and returning them to general classroom instruction. Researchers assessed kindergarten students (N = 105) identified as at risk who…

  11. False-positive results in mammographic screening for breast cancer in Europe

    DEFF Research Database (Denmark)

    Hofvind, Solveig; Ponti, Antonio; Patnick, Julietta

    2012-01-01

    To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment.......To estimate the cumulative risk of a false-positive screening result in European mammographic screening programmes, and examine the rates and procedures of further assessment....

  12. Risk of breast cancer after false-positive results in mammographic screening

    DEFF Research Database (Denmark)

    Roman, Marta; Castells, Xavier; Hofvind, Solveig

    2016-01-01

    risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50–69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1......Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level.......4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93–2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77–1.96), whereas those who tested false-positive at third screening had a RR...

  13. Increased risk of breast cancer in women with false-positive test

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Kuchiki, Megumi; Vejborg, Ilse

    2014-01-01

    of misclassification, i.e. women who were actually false-negatives instead of false-positives. METHOD: We used data from the Copenhagen Mammography Screening Programme, Denmark. The study population was the 295 women, out of 4743 recalled women from a total of 58,003 participants, with a false-positive test during...... the women with misclassified tests had been excluded, there was an excess risk of breast cancer of 27% (RR=1.27, 95% confidence interval (CI), 1.11-1.46) among the women with a false-positive test compared to women with only negative tests. Women with a false-positive test determined at assessment had...... an excess risk of 27%, while false-positives determined at surgery had an excess risk of 30%. CONCLUSIONS: The results indicate that the increased risk is not explained only by misclassification. The excess risk remains for false-positives determined at assessment as well as at surgery, which favours some...

  14. Reducing false-positive incidental findings with ensemble genotyping and logistic regression based variant filtering methods.

    Science.gov (United States)

    Hwang, Kyu-Baek; Lee, In-Hee; Park, Jin-Ho; Hambuch, Tina; Choe, Yongjoon; Kim, MinHyeok; Lee, Kyungjoon; Song, Taemin; Neu, Matthew B; Gupta, Neha; Kohane, Isaac S; Green, Robert C; Kong, Sek Won

    2014-08-01

    As whole genome sequencing (WGS) uncovers variants associated with rare and common diseases, an immediate challenge is to minimize false-positive findings due to sequencing and variant calling errors. False positives can be reduced by combining results from orthogonal sequencing methods, but costly. Here, we present variant filtering approaches using logistic regression (LR) and ensemble genotyping to minimize false positives without sacrificing sensitivity. We evaluated the methods using paired WGS datasets of an extended family prepared using two sequencing platforms and a validated set of variants in NA12878. Using LR or ensemble genotyping based filtering, false-negative rates were significantly reduced by 1.1- to 17.8-fold at the same levels of false discovery rates (5.4% for heterozygous and 4.5% for homozygous single nucleotide variants (SNVs); 30.0% for heterozygous and 18.7% for homozygous insertions; 25.2% for heterozygous and 16.6% for homozygous deletions) compared to the filtering based on genotype quality scores. Moreover, ensemble genotyping excluded > 98% (105,080 of 107,167) of false positives while retaining > 95% (897 of 937) of true positives in de novo mutation (DNM) discovery in NA12878, and performed better than a consensus method using two sequencing platforms. Our proposed methods were effective in prioritizing phenotype-associated variants, and an ensemble genotyping would be essential to minimize false-positive DNM candidates. © 2014 WILEY PERIODICALS, INC.

  15. The effect of recumbency position on the ultrasound measurement of the canine adrenal gland in non-adrenal gland illness

    Directory of Open Access Journals (Sweden)

    Rose AM

    2017-11-01

    Full Text Available Anne Marie Rose,1 Thurid Johnstone,1,2 Sue Finch,3 Cathy Beck1 1U-Vet Animal Hospital Werribee, The University of Melbourne, 2TRACTS Translational Research and Clinical Trial Study Group, The University of Melbourne, 3Statistical Consulting Centre, School of Mathematics and Statistics, The University of Melbourne, Melbourne, VIC, Australia Abstract: Abdominal ultrasound is frequently used to assess the canine adrenal gland (AG and subjective and objective features of normal AGs have been described. The effect of the dogs’ recumbency position on the accuracy of AG measurement acquisition is not known. This prospective study, performed in dogs with non-adrenal illness, compared ultrasonographic AG measurements made in dogs placed in dorsal recumbency with those made in left or right lateral recumbency. AG length, height and width measurements made in the longitudinal image plane, and height and width measurements from the transverse image plane were assessed. The level and limits of agreement between the dorsal and lateral recumbency for each of the measurements were determined using the Bland–Altman analysis. The measurement with the best agreement between the dorsal and lateral recumbency was the caudal pole thickness (CPT from the longitudinal image plane. Agreement between lateral and dorsal recumbency was poorer for the measurements derived from the transverse image plane and poorest for measurements of AG length in the longitudinal plane. This study demonstrates that there is some difference in the measurements acquired in dorsal compared with lateral recumbency; however, the difference is small for the CPT from the longitudinal plane. This finding suggests that the CPT from the longitudinal image plane is the most reliable measurement in terms of agreement between dorsal and lateral recumbency in dogs with non-AG illness. Keywords: adrenal glands, ultrasonography, normal, dog, recumbency

  16. Comparison of cumulative false-positive risk of screening mammography in the United States and Denmark

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp

    2015-01-01

    INTRODUCTION: In the United States (US), about one-half of women screened with annual mammography have at least one false-positive test after ten screens. The estimate for European women screened ten times biennially is much lower. We evaluate to what extent screening interval, mammogram type......=400,204), between 1991-2012 and 1993-2013, respectively. Model-based cumulative false-positive risks were computed for the entire sample, using two statistical methods (Hubbard Njor) previously used to estimate false-positive risks in the US and Europe. RESULTS: Empirical cumulative risk of at least...... one false-positive test after eight (annual or biennial) screens was 41.9% in BCSC, 16.1% in Copenhagen, and 7.4% in Funen. Variation in screening interval and mammogram type did not explain the differences by country. Using the Hubbard method, the model-based cumulative risks after eight screens...

  17. Risk of breast cancer after false-positive results in mammographic screening.

    Science.gov (United States)

    Román, Marta; Castells, Xavier; Hofvind, Solveig; von Euler-Chelpin, My

    2016-06-01

    Women with false-positive results are commonly referred back to routine screening. Questions remain regarding their long-term outcome of breast cancer. We assessed the risk of screen-detected breast cancer in women with false-positive results. We conducted a joint analysis using individual level data from the population-based screening programs in Copenhagen and Funen in Denmark, Norway, and Spain. Overall, 150,383 screened women from Denmark (1991-2008), 612,138 from Norway (1996-2010), and 1,172,572 from Spain (1990-2006) were included. Poisson regression was used to estimate the relative risk (RR) of screen-detected cancer for women with false-positive versus negative results. We analyzed information from 1,935,093 women 50-69 years who underwent 6,094,515 screening exams. During an average 5.8 years of follow-up, 230,609 (11.9%) women received a false-positive result and 27,849 (1.4%) were diagnosed with screen-detected cancer. The adjusted RR of screen-detected cancer after a false-positive result was 2.01 (95% CI: 1.93-2.09). Women who tested false-positive at first screen had a RR of 1.86 (95% CI: 1.77-1.96), whereas those who tested false-positive at third screening had a RR of 2.42 (95% CI: 2.21-2.64). The RR of breast cancer at the screening test after the false-positive result was 3.95 (95% CI: 3.71-4.21), whereas it decreased to 1.25 (95% CI: 1.17-1.34) three or more screens after the false-positive result. Women with false-positive results had a twofold risk of screen-detected breast cancer compared to women with negative tests. The risk remained significantly higher three or more screens after the false-positive result. The increased risk should be considered when discussing stratified screening strategies. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  18. Psychological effects of false-positive results in expanded newborn screening in China.

    Directory of Open Access Journals (Sweden)

    Wen-Jun Tu

    Full Text Available OBJECTIVES: As more families participate expanded newborn screening for metabolic disorders in China, the overall number of false positives increases. Our goal was to assess the potential impact on parental stress, perceptions of the child's health, and family relationships. METHODS: Parents of 49 infants with false-positive screening results for metabolic disorders in the expanded newborn screening panel were compared with parents of 42 children with normal screening results. Parents first completed structured interview using likert scales, closed and open questions. Parents also completed the parenting stress index. RESULTS: A total of 88 mothers and 41 fathers were interviewed. More mothers in the false-positive group reported that their children required extra parental care (21%, compared with 5% of mothers in the normal-screened group (P<0.001. 39% of mothers in the false-positive group reported that they worry about their child's future development, compared with 10% of mothers in the normal-screened group (P<0.001. Fathers in the false-positive group did not differ from fathers in the normal-screened group in reporting worry about their child's extra care requirements, and their child's future development. Children with false-positive results compared with children with normal results were triple as likely to experience hospitalization (27%vs 9%, respectively; P<0.001. CONCLUSIONS: The results showing false-positive screening results may affect parental stress and the parent-child relationship. Parental stress and anxiety can be reduced with improved education and communication to parents about false-positive results.

  19. Is there a positive bias in false recognition? Evidence from confabulating amnesia patients.

    Science.gov (United States)

    Alkathiri, Nura H; Morris, Robin G; Kopelman, Michael D

    2015-10-01

    Although there is some evidence for a positive emotional bias in the content of confabulations in brain damaged patients, findings have been inconsistent. The present study used the semantic-associates procedure to induce false recall and false recognition in order to examine whether a positive bias would be found in confabulating amnesic patients, relative to non-confabulating amnesic patients and healthy controls. Lists of positive, negative and neutral words were presented in order to induce false recall or false recognition of non-presented (but semantically associated) words. The latter were termed 'critical intrusions'. Thirteen confabulating amnesic patients, 13 non-confabulating amnesic patients and 13 healthy controls were investigated. Confabulating patients falsely recognised a higher proportion of positive (but unrelated) words, compared with non-confabulating patients and healthy controls. No differences were found for recall memory. Signal detection analysis, however, indicated that the positive bias for false recognition memory might reflect weaker memory in the confabulating amnesic group. This suggested that amnesia patients with weaker memory are more likely to confabulate and the content of these confabulations are more likely to be positive. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Skin irritation, false positives and the local lymph node assay: a guideline issue?

    Science.gov (United States)

    Basketter, David A; Kimber, Ian

    2011-10-01

    Since the formal validation and regulatory acceptance of the local lymph node assay (LLNA) there have been commentaries suggesting that the irritant properties of substances can give rise to false positives. As toxicology aspires to progress rapidly towards the age of in vitro alternatives, it is of increasing importance that issues relating to assay selectivity and performance are understood fully, and that true false positive responses are distinguished clearly from those that are simply unpalatable. In the present review, we have focused on whether skin irritation per se is actually a direct cause of true false positive results in the LLNA. The body of published work has been examined critically and considered in relation to our current understanding of the mechanisms of skin irritation and skin sensitisation. From these analyses it is very clear that, of itself, skin irritation is not a cause of false positive results. The corollary is, therefore, that limiting test concentrations in the LLNA for the purpose of avoiding skin irritation may lead, unintentionally, to false negatives. Where a substance is a true false positive in the LLNA, the classic example being sodium lauryl sulphate, explanations for that positivity will have to reach beyond the seductive, but incorrect, recourse to its skin irritation potential. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Study of false positives in 5-ALA induced photodynamic diagnosis of bladder carcinoma

    Science.gov (United States)

    Draga, Ronald O. P.; Grimbergen, Matthijs C. M.; Kok, Esther T.; Jonges, Trudy G. N.; Bosch, J. L. H. R.

    2009-02-01

    Photodynamic diagnosis (PDD) is a technique that enhances the detection of tumors during cystoscopy using a photosensitizer which accumulates primarily in cancerous cells and will fluoresce when illuminated by violetblue light. A disadvantage of PDD is the relatively low specificity. In this retrospective study we aimed to identify predictors for false positive findings in PDD. Factors such as gender, age, recent transurethral resection of bladder tumors (TURBT), previous intravesical therapy (IVT) and urinary tract infections (UTIs) were examined for association with the false positive rates in a multivariate analysis. Data of 366 procedures and 200 patients were collected. Patients were instilled with 5-aminolevulinic acid (5-ALA) intravesically and 1253 biopsies were taken from tumors and suspicious lesions. Female gender and TURBT are independent predictors of false positives in PDD. However, previous intravesical therapy with Bacille Calmette-Guérin is also an important predictor of false positives. The false positive rate decreases during the first 9-12 weeks after the latest TURBT and the latest intravesical chemotherapy. Although shortly after IVT and TURBT false positives increase, PDD improves the diagnostic sensitivity and results in more adequate treatment strategies in a significant number of patients.

  2. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  3. Performance quantification of clustering algorithms for false positive removal in fMRI by ROC curves

    Directory of Open Access Journals (Sweden)

    André Salles Cunha Peres

    Full Text Available Abstract Introduction Functional magnetic resonance imaging (fMRI is a non-invasive technique that allows the detection of specific cerebral functions in humans based on hemodynamic changes. The contrast changes are about 5%, making visual inspection impossible. Thus, statistic strategies are applied to infer which brain region is engaged in a task. However, the traditional methods like general linear model and cross-correlation utilize voxel-wise calculation, introducing a lot of false-positive data. So, in this work we tested post-processing cluster algorithms to diminish the false-positives. Methods In this study, three clustering algorithms (the hierarchical cluster, k-means and self-organizing maps were tested and compared for false-positive removal in the post-processing of cross-correlation analyses. Results Our results showed that the hierarchical cluster presented the best performance to remove the false positives in fMRI, being 2.3 times more accurate than k-means, and 1.9 times more accurate than self-organizing maps. Conclusion The hierarchical cluster presented the best performance in false-positive removal because it uses the inconsistency coefficient threshold, while k-means and self-organizing maps utilize a priori cluster number (centroids and neurons number; thus, the hierarchical cluster avoids clustering scattered voxels, as the inconsistency coefficient threshold allows only the voxels to be clustered that are at a minimum distance to some cluster.

  4. Assessment of potential false positives via orbitrap-based untargeted lipidomics from rat tissues.

    Science.gov (United States)

    Xu, Lina; Wang, Xueying; Jiao, Yupei; Liu, Xiaohui

    2018-02-01

    Untargeted lipidomics is increasingly popular due to the broad coverage of lipid species. Data dependent MS/MS acquisition is commonly used in order to acquire sufficient information for confident lipid assignment. However, although lipids are identified based on MS/MS confirmation, a number of false positives are still observed. Here, we discuss several causes of introducing lipid false identifications in untargeted analysis. Phosphotidylcholines and cholesteryl esters generate in-source fragmentation to produce dimethylated phosphotidylethanolamine and free cholesterol. Dimerization of fatty acid results in false identification of fatty acid ester of hydroxyl fatty acid. Realizing these false positives is able to improve confidence of results acquired from untargeted analysis. Besides, thresholds are established for lipids identified using LipidSearch v4.1.16 software to reduce unreliable results. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications.

    Science.gov (United States)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; den Heeten, Gerard; Karssemeijer, Nico

    2016-04-01

    In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists' detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8-1.0 were

  6. Evaluation of positive and false-positive results in syphilis screening of blood donors in Rio de Janeiro, Brazil.

    Science.gov (United States)

    Sandes, V S; Silva, S G C; Motta, I J F; Velarde, L G C; de Castilho, S R

    2017-06-01

    We propose to analyse the positive and false-positive results of treponemal and nontreponemal tests in blood donors from Brazil and to evaluate possible factors associated with the results of treponemal tests. Treponemal tests have been used widely for syphilis screening in blood banks. The introduction of these tests in donor screening has caused an impact and a loss of donors who need to be assessed. This was a retrospective cross-sectional study of syphilis screening and confirmatory test results of blood donors that were obtained before and after adopting a chemiluminescent immunoassay (CLIA). A comparative analysis was performed using a second sample drawn from positive donors. The possible factors associated with CLIA-positive or CLIA-false-positive results were investigated in a subgroup. Statistical tests were used to compare the proportions and adjusted estimates of association. The reactivity rate increased from 1·01% (N = 28 158) to 2·66% (N = 25 577) after introducing the new test. Among Venereal Disease Research Laboratory (VDRL)- and CLIA-confirmed results, the false-positive rates were 40·5% (N = 180) and 37·4% (N = 359), respectively (P = 0·5266). Older donors (OR = 1·04; P = 0·0010) and donors with lower education levels (OR = 6·59; P = 0·0029) were associated with a higher risk of positivity for syphilis. CLIA represents an improvement in blood bank serological screening. However, its use in a healthy population appears to result in high rates of false positives. Identifying which characteristics can predict false positives, however, remains a challenge. © 2017 British Blood Transfusion Society.

  7. Sherlock Holmes and child psychopathology assessment approaches: the case of the false-positive.

    Science.gov (United States)

    Jensen, P S; Watanabe, H

    1999-02-01

    To explore the relative value of various methods of assessing childhood psychopathology, the authors compared 4 groups of children: those who met criteria for one or more DSM diagnoses and scored high on parent symptom checklists, those who met psychopathology criteria on either one of these two assessment approaches alone, and those who met no psychopathology assessment criterion. Parents of 201 children completed the Child Behavior Checklist (CBCL), after which children and parents were administered the Diagnostic Interview Schedule for Children (version 2.1). Children and parents also completed other survey measures and symptom report inventories. The 4 groups of children were compared against "external validators" to examine the merits of "false-positive" and "false-negative" cases. True-positive cases (those that met DSM criteria and scored high on the CBCL) differed significantly from the true-negative cases on most external validators. "False-positive" and "false-negative" cases had intermediate levels of most risk factors and external validators. "False-positive" cases were not normal per se because they scored significantly above the true-negative group on a number of risk factors and external validators. A similar but less marked pattern was noted for "false-negatives." Findings call into question whether cases with high symptom checklist scores despite no formal diagnoses should be considered "false-positive." Pending the availability of robust markers for mental illness, researchers and clinicians must resist the tendency to reify diagnostic categories or to engage in arcane debates about the superiority of one assessment approach over another.

  8. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    Science.gov (United States)

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  9. Algorithm of reducing the false positives in IDS based on correlation Analysis

    Science.gov (United States)

    Liu, Jianyi; Li, Sida; Zhang, Ru

    2018-03-01

    This paper proposes an algorithm of reducing the false positives in IDS based on correlation Analysis. Firstly, the algorithm analyzes the distinguishing characteristics of false positives and real alarms, and preliminary screen the false positives; then use the method of attribute similarity clustering to the alarms and further reduces the amount of alarms; finally, according to the characteristics of multi-step attack, associated it by the causal relationship. The paper also proposed a reverse causation algorithm based on the attack association method proposed by the predecessors, turning alarm information into a complete attack path. Experiments show that the algorithm simplifies the number of alarms, improve the efficiency of alarm processing, and contribute to attack purposes identification and alarm accuracy improvement.

  10. Categorizing Mistaken False Positives in Regulation of Human and Environmental Health

    DEFF Research Database (Denmark)

    Hansen, Steffen Foss; Krayer von Krauss, Martin Paul; Tickner, J.A.

    2007-01-01

    One of the concerns often voiced by critics of the precautionary principle is that a widespread regulatory application of the principle will lead to a large number of false positives (i.e., over-regulation of minor risks and regulation of nonexisting risks). The present article proposes a general......," including: real risks, "The jury is still out," nonregulated proclaimed risks, "Too narrow a definition of risk," and risk-risk tradeoffs. These categories are defined and examples are presented in order to illustrate their key characteristics. On the basis of our analysis, we were able to identify only...... four cases that could be defined as regulatory false positives in the light of today's knowledge and recognized uncertainty: the Southern Corn Leaf Blight, the Swine Flu, Saccharin, and Food Irradiation in relation to consumer health. We conclude that concerns about false positives do not represent...

  11. Image Watermarking Scheme for Specifying False Positive Probability and Bit-pattern Embedding

    Science.gov (United States)

    Sayama, Kohei; Nakamoto, Masayoshi; Muneyasu, Mitsuji; Ohno, Shuichi

    This paper treats a discrete wavelet transform(DWT)-based image watermarking with considering the false positive probability and bit-pattern embedding. We propose an iterative embedding algorithm of watermarking signals which are K sets pseudo-random numbers generated by a secret key. In the detection, K correlations between the watermarked DWT coefficients and watermark signals are computed by using the secret key. L correlations are made available for the judgment of the watermark presence with specified false positive probability, and the other K-L correlations are corresponding to the bit-pattern signal. In the experiment, we show the detection results with specified false positive probability and the bit-pattern recovery, and the comparison of the proposed method against JPEG compression, scaling down and cropping.

  12. [Evaluation of performance and false positivity of Mediace RPR test that uses a chemistry autoanalyzer].

    Science.gov (United States)

    Noh, Jaekwang; Ko, Hak Hyun; Yun, Yeomin; Choi, Young Sook; Lee, Sang Gon; Shin, Sue; Han, Kyou Sup; Song, Eun Young

    2008-08-01

    We evaluated the performance and false positive rate of Mediace RPR test (Sekisui, Japan), a newly introduced nontreponemal test using a chemistry autoanalyzer. The sensitivity of Mediace RPR test was analyzed using sera from 50 patients with syphilis in different stages (8 primary, 7 secondary, and 35 latent), 14 sera positive with fluorescent treponemal antibody absorption (FTA-ABS) IgM, and 74 sera positive with conventional rapid plasma regain (RPR) card test (Asan, Korea) and also positive with Treponema pallidum hemagglutination (TPHA) test or FTA-ABS IgG test. The specificity was analyzed on 108 healthy blood donors. We also performed RPR card test on 302 sera that had been tested positive with Mediace RPR test and also performed TPHA or FTA-ABS IgG test to analyze the false positive rate of Mediace RPR test. A cutoff value of 0.5 R.U. (RPR unit) was used for Mediace RPR test. Mediace RPR test on syphilitic sera of different stages (primary, secondary, and latent stages) and FTA-ABS IgM positive sera showed a sensitivity of 100%, 100%, 82.9% and 100%, respectively. Among the 74 sera positive with conventional RPR card test and TPHA or FTA-ABS IgG test, 55 were positive with Mediace test. The specificity of Mediace RPR test on blood donors was 97.2%. Among the 302 sera positive with Mediace RPR test, 137 sera (45.4%) were negative by RPR card and TPHA/FTA-ABS IgG tests. Although the sensitivities of Mediace RPR were good for primary and secondary syphilis, due to its high negative rate of Mediace RPR over the conventional RPR positive samples, further studies are necessary whether it can replace conventional nontreponemal test for screening purpose. Moreover, in view of the high false positive rate, positive results by Mediace RPR test should be confirmed with treponemal tests.

  13. Newly formed skeletal muscle fibers are prone to false positive immunostaining by rabbit antibodies

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Kliem, Anette; Schrøder, Henrik Daa

    2011-01-01

    rely on controls that reveal non-specific binding by the secondary antibody and neglect that the primary rabbit antibody itself may cause false positive staining of the muscle. We suggest that reliable immuno-based protein detection in newly formed muscle fibers at least requires a nonsense rabbit......Reports on muscle biology and regeneration often implicate immuno(cyto/histo)chemical protein characterization using rabbit polyclonal antibodies. In this study we demonstrate that newly formed myofibers are especially prone to false positive staining by rabbit antibodies and this unwanted staining...

  14. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  15. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  16. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    International Nuclear Information System (INIS)

    Mordang, Jan-Jurre; Gubern-Mérida, Albert; Karssemeijer, Nico; Heeten, Gerard den

    2016-01-01

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  17. Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    Energy Technology Data Exchange (ETDEWEB)

    Mordang, Jan-Jurre, E-mail: Jan-Jurre.Mordang@radboudumc.nl; Gubern-Mérida, Albert; Karssemeijer, Nico [Diagnostic Image Analysis Group, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen 6525 GA (Netherlands); Heeten, Gerard den [The National Training Centre for Breast Cancer Screening, Nijmegen 6503 GJ, The Netherlands and Department of Radiology, Amsterdam Medical Center, Amsterdam 1100 DD (Netherlands)

    2016-04-15

    Purpose: In the past decades, computer-aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications. Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case-based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings. Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free-response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity

  18. Benign lymphoepithelial cysts of the parotid glands in HIV-positive patients. A case report

    International Nuclear Information System (INIS)

    Piqueras, R.M.; Marco, S.F.; Lazaro, S.; Gonzlez, M.

    1997-01-01

    Benign parotid lymphoepithelial cysts (BPLEC) with cervical lymph node involvement are a recently reported radiological sign of HIV infection in head and neck in patients ar risk for developing AIDS. These cysts lesions present in the parotid glands of HIV-positive individuals and are associated with cervical lymph node involvement. We present a case of BPLEC in a HIV-positive patients that was studied by ultrasound and computerized tomography. The diagnosis was confirmed by ultrasound-guided percutaneous biopsy. We describe the radiological signs of this lesion as detected by the imaging techniques employed and we establish the differential diagnosis. (Author) 14 refs

  19. Hemorrhoids detected at colonoscopy: an infrequent cause of false-positive fecal immunochemical test results.

    NARCIS (Netherlands)

    Turenhout, S.T. van; Oort, F.A.; Terhaar sive Droste, J.S.; Coupe, V.M.; Hulst, R.W. van der; Loffeld, R.J.; Scholten, P.; Depla, A.C.; Bouman, A.A.; Meijer, G.A.; Mulder, C.J.; Rossum, L.G.M. van

    2012-01-01

    BACKGROUND: Colorectal cancer screening by fecal immunochemical tests (FITs) is hampered by frequent false-positive (FP) results and thereby the risk of complications and strain on colonoscopy capacity. Hemorrhoids might be a plausible cause of FP results. OBJECTIVE: To determine the contribution of

  20. IS HCI THAT IS USED AS A PRESERVATIVE CREATING FALSE POSITIVES FOR TBA IN GROUND WATER

    Science.gov (United States)

    Will hydrochloric acid produce false positives for TBA? Yes, if you heat the sample to get a lower detection limit for TBA. Conventional purge and trap methods at ambient temperature have a reporting limit for TBA between 50 and 100 g/liter. This is higher than the provisiona...

  1. False-Positive Rate of AKI Using Consensus Creatinine-Based Criteria.

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G S; Negoianu, Dan; Testani, Jeffrey M; Berns, Jeffrey S; Parikh, Chirag R; Wilson, F Perry

    2015-10-07

    Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false-positive rates because of inherent laboratory and biologic variabilities of creatinine. We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false-positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient's true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false-positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%-8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false-positive AKI diagnosis rate of 30.5% (interquartile range =30.1%-30.9%) versus 2.0% (interquartile range =1.9%-2.1%) in patients with true serum creatinine values false-positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. Copyright © 2015 by the American Society of Nephrology.

  2. Positive events protect children from causal false memories for scripted events.

    Science.gov (United States)

    Melinder, Annika; Toffalini, Enrico; Geccherle, Eleonora; Cornoldi, Cesare

    2017-11-01

    Adults produce fewer inferential false memories for scripted events when their conclusions are emotionally charged than when they are neutral, but it is not clear whether the same effect is also found in children. In the present study, we examined this issue in a sample of 132 children aged 6-12 years (mean 9 years, 3 months). Participants encoded photographs depicting six script-like events that had a positively, negatively, or a neutral valenced ending. Subsequently, true and false recognition memory of photographs related to the observed scripts was tested as a function of emotionality. Causal errors-a type of false memory thought to stem from inferential processes-were found to be affected by valence: children made fewer causal errors for positive than for neutral or negative events. Hypotheses are proposed on why adults were found protected against inferential false memories not only by positive (as for children) but also by negative endings when administered similar versions of the same paradigm.

  3. Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?

    Science.gov (United States)

    Yoon, Jung Hyun; Jung, Hae Kyoung; Lee, Jong Tae; Ko, Kyung Hee

    2013-09-01

    To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses. From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3 ± 10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the 'true' and 'false' groups were compared. Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P breast masses had SWE images of good quality. False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition. • Shear-wave elastography (SWE) is widely used during breast imaging • At SWE, false-positive rates were significantly higher than false-negative rates • Larger size, breast thickness, depth and fair quality influences false-positive SWE features • Smaller size, larger breast thickness and depth influences false-negative SWE features.

  4. False positive reduction in protein-protein interaction predictions using gene ontology annotations

    Directory of Open Access Journals (Sweden)

    Lin Yen-Han

    2007-07-01

    Full Text Available Abstract Background Many crucial cellular operations such as metabolism, signalling, and regulations are based on protein-protein interactions. However, the lack of robust protein-protein interaction information is a challenge. One reason for the lack of solid protein-protein interaction information is poor agreement between experimental findings and computational sets that, in turn, comes from huge false positive predictions in computational approaches. Reduction of false positive predictions and enhancing true positive fraction of computationally predicted protein-protein interaction datasets based on highly confident experimental results has not been adequately investigated. Results Gene Ontology (GO annotations were used to reduce false positive protein-protein interactions (PPI pairs resulting from computational predictions. Using experimentally obtained PPI pairs as a training dataset, eight top-ranking keywords were extracted from GO molecular function annotations. The sensitivity of these keywords is 64.21% in the yeast experimental dataset and 80.83% in the worm experimental dataset. The specificities, a measure of recovery power, of these keywords applied to four predicted PPI datasets for each studied organisms, are 48.32% and 46.49% (by average of four datasets in yeast and worm, respectively. Based on eight top-ranking keywords and co-localization of interacting proteins a set of two knowledge rules were deduced and applied to remove false positive protein pairs. The 'strength', a measure of improvement provided by the rules was defined based on the signal-to-noise ratio and implemented to measure the applicability of knowledge rules applying to the predicted PPI datasets. Depending on the employed PPI-predicting methods, the strength varies between two and ten-fold of randomly removing protein pairs from the datasets. Conclusion Gene Ontology annotations along with the deduced knowledge rules could be implemented to partially

  5. False positive seroreactivity to brucellosis in tuberculosis patients: a prevalence study

    Directory of Open Access Journals (Sweden)

    Mojtaba Varshochi

    2011-03-01

    Full Text Available Mojtaba Varshochi1,2, Jafar Majidi2, Marjan Amini1, Kamyar Ghabili3, Mohammadali M Shoja31Department of Infectious Disease, Tabriz University of Medical Sciences, Tabriz, Iran; 2Infectious Disease and Tropical Medicine Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; 3Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz, IranBackground: The rising worldwide incidence of tuberculosis (TB increases the demand for knowledge about its potential seroreactivity with other microbial agents. A few reports and the authors’ experiences indicate that tuberculosis may result in a false-positive brucellosis serology. This may cause a diagnostic challenge because of the close clinical resemblance of these two infections.Objective: The aim of the present prevalence study was to elucidate brucellosis seroreactivity in patients with active TB.Methods: Ninety-eight patients with newly diagnosed and active TB were studied using an enzyme-linked immunosorbent assay (ELISA and Wright’s and Coombs–Wright’s tests. Seventy-five healthy individuals were used as controls. The patients showed signs of recovery after starting a standard anti-TB regimen and had no clinical evidence of brucellosis at a subsequent 6-month follow-up. The data were analyzed statistically by Fisher’s exact test using SPSS 11.0.Results: We found that 9.2% of TB patients versus 1.3% of healthy controls had positive results on the anti-Brucella IgG ELISA (P = 0.04. Five TB patients were found to have agglutination on Wright’s tests, while none of the controls showed agglutination.Conclusion: Active TB patients may have some seroreactivity with Brucella antigens, and Brucella IgG ELISA may give a false positive in these patients. Clinicians should consider false positive brucellosis seroreactivity in patients with active TB.Keywords: false positive serology, ELISA, diagnosis

  6. Waiting time and the psychosocial consequences of false-positive mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert; Brodersen, John

    2015-01-01

    Background: There is wide variation in the psychosocial response to false-positive mammography. We aimed to assess whether women having to wait longer to exclude cancer had increased psychosocial consequences that persisted after cancer was ruled out. Findings: We selected women with false......-positive mammography (n = 272), screened for breast cancer in Copenhagen and Funen (Denmark) over a 1-year period. We measured psychosocial consequences immediately before women attended their recall visit and 1, 6, 18 and 36 months after women received their final diagnosis. After women were told that cancer had been...... ruled out, adverse psychosocial consequences decreased with time. We found no statistically significant differences between women who had cancer ruled out immediately at the recall visit (waiting time of 0) and women who had to wait longer before cancer was ruled out (waiting times 1-30, 30...

  7. Long-term psychosocial consequences of false-positive screening mammography

    DEFF Research Database (Denmark)

    Brodersen, John; Siersma, Volkert Dirk

    2013-01-01

    Cancer screening programs have the potential of intended beneficial effects, but they also inevitably have unintended harmful effects. In the case of screening mammography, the most frequent harm is a false-positive result. Prior efforts to measure their psychosocial consequences have been limite...... by short-term follow-up, the use of generic survey instruments, and the lack of a relevant benchmark-women with breast cancer....

  8. Cross-reactive Carbohydrate Determinant Contributes to the False Positive IgE Antibody to Peanut

    Directory of Open Access Journals (Sweden)

    Komei Ito

    2005-01-01

    Conclusions: Social education about the features of peanut allergy is needed in Japan. Anti-CCD IgE antibody was suggested to be one of the mechanisms contributing to the false positive detection of peanut IgE. Detection of anti-HRP or anti-bromelain IgE can be a useful tool to recognize the presence of anti-CCD antibodies.

  9. Shape based automated detection of pulmonary nodules with surface feature based false positive reduction

    International Nuclear Information System (INIS)

    Nomura, Y.; Itoh, H.; Masutani, Y.; Ohtomo, K.; Maeda, E.; Yoshikawa, T.; Hayashi, N.

    2007-01-01

    We proposed a shape based automated detection of pulmonary nodules with surface feature based false positive (FP) reduction. In the proposed system, the FP existing in internal of vessel bifurcation is removed using extracted surface of vessels and nodules. From the validation with 16 chest CT scans, we find that the proposed CAD system achieves 18.7 FPs/scan at 90% sensitivity, and 7.8 FPs/scan at 80% sensitivity. (orig.)

  10. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  11. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    Energy Technology Data Exchange (ETDEWEB)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-11-19

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of ..beta..-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment.

  12. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    International Nuclear Information System (INIS)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-01-01

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of #betta#-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment

  13. Multilevel Contextual 3-D CNNs for False Positive Reduction in Pulmonary Nodule Detection.

    Science.gov (United States)

    Dou, Qi; Chen, Hao; Yu, Lequan; Qin, Jing; Heng, Pheng-Ann

    2017-07-01

    False positive reduction is one of the most crucial components in an automated pulmonary nodule detection system, which plays an important role in lung cancer diagnosis and early treatment. The objective of this paper is to effectively address the challenges in this task and therefore to accurately discriminate the true nodules from a large number of candidates. We propose a novel method employing three-dimensional (3-D) convolutional neural networks (CNNs) for false positive reduction in automated pulmonary nodule detection from volumetric computed tomography (CT) scans. Compared with its 2-D counterparts, the 3-D CNNs can encode richer spatial information and extract more representative features via their hierarchical architecture trained with 3-D samples. More importantly, we further propose a simple yet effective strategy to encode multilevel contextual information to meet the challenges coming with the large variations and hard mimics of pulmonary nodules. The proposed framework has been extensively validated in the LUNA16 challenge held in conjunction with ISBI 2016, where we achieved the highest competition performance metric (CPM) score in the false positive reduction track. Experimental results demonstrated the importance and effectiveness of integrating multilevel contextual information into 3-D CNN framework for automated pulmonary nodule detection in volumetric CT data. While our method is tailored for pulmonary nodule detection, the proposed framework is general and can be easily extended to many other 3-D object detection tasks from volumetric medical images, where the targeting objects have large variations and are accompanied by a number of hard mimics.

  14. A deep 3D residual CNN for false-positive reduction in pulmonary nodule detection.

    Science.gov (United States)

    Jin, Hongsheng; Li, Zongyao; Tong, Ruofeng; Lin, Lanfen

    2018-05-01

    The automatic detection of pulmonary nodules using CT scans improves the efficiency of lung cancer diagnosis, and false-positive reduction plays a significant role in the detection. In this paper, we focus on the false-positive reduction task and propose an effective method for this task. We construct a deep 3D residual CNN (convolution neural network) to reduce false-positive nodules from candidate nodules. The proposed network is much deeper than the traditional 3D CNNs used in medical image processing. Specifically, in the network, we design a spatial pooling and cropping (SPC) layer to extract multilevel contextual information of CT data. Moreover, we employ an online hard sample selection strategy in the training process to make the network better fit hard samples (e.g., nodules with irregular shapes). Our method is evaluated on 888 CT scans from the dataset of the LUNA16 Challenge. The free-response receiver operating characteristic (FROC) curve shows that the proposed method achieves a high detection performance. Our experiments confirm that our method is robust and that the SPC layer helps increase the prediction accuracy. Additionally, the proposed method can easily be extended to other 3D object detection tasks in medical image processing. © 2018 American Association of Physicists in Medicine.

  15. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension

    International Nuclear Information System (INIS)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya; Fukutake, Toshio.

    1982-01-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH 2 O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH 2 O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered. (author)

  16. Proteins interacting with cloning scars: a source of false positive protein-protein interactions.

    Science.gov (United States)

    Banks, Charles A S; Boanca, Gina; Lee, Zachary T; Florens, Laurence; Washburn, Michael P

    2015-02-23

    A common approach for exploring the interactome, the network of protein-protein interactions in cells, uses a commercially available ORF library to express affinity tagged bait proteins; these can be expressed in cells and endogenous cellular proteins that copurify with the bait can be identified as putative interacting proteins using mass spectrometry. Control experiments can be used to limit false-positive results, but in many cases, there are still a surprising number of prey proteins that appear to copurify specifically with the bait. Here, we have identified one source of false-positive interactions in such studies. We have found that a combination of: 1) the variable sequence of the C-terminus of the bait with 2) a C-terminal valine "cloning scar" present in a commercially available ORF library, can in some cases create a peptide motif that results in the aberrant co-purification of endogenous cellular proteins. Control experiments may not identify false positives resulting from such artificial motifs, as aberrant binding depends on sequences that vary from one bait to another. It is possible that such cryptic protein binding might occur in other systems using affinity tagged proteins; this study highlights the importance of conducting careful follow-up studies where novel protein-protein interactions are suspected.

  17. Analyzing false positives of four questions in the Force Concept Inventory

    Science.gov (United States)

    Yasuda, Jun-ichiro; Mae, Naohiro; Hull, Michael M.; Taniguchi, Masa-aki

    2018-06-01

    In this study, we analyze the systematic error from false positives of the Force Concept Inventory (FCI). We compare the systematic errors of question 6 (Q.6), Q.7, and Q.16, for which clearly erroneous reasoning has been found, with Q.5, for which clearly erroneous reasoning has not been found. We determine whether or not a correct response to a given FCI question is a false positive using subquestions. In addition to the 30 original questions, subquestions were introduced for Q.5, Q.6, Q.7, and Q.16. This modified version of the FCI was administered to 1145 university students in Japan from 2015 to 2017. In this paper, we discuss our finding that the systematic errors of Q.6, Q.7, and Q.16 are much larger than that of Q.5 for students with mid-level FCI scores. Furthermore, we find that, averaged over the data sample, the sum of the false positives from Q.5, Q.6, Q.7, and Q.16 is about 10% of the FCI score of a midlevel student.

  18. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, Jan-Jurre; Gubern-Merida, Albert; Bria, Alessandro; Tortorella, Francesco; den Heeten, Gerard; Karssemeijer, Nico

    2017-01-01

    Purpose: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  19. Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    NARCIS (Netherlands)

    Mordang, J.J.; Gubern Merida, A.; Bria, A.; Tortorella, F.; Heeten, G.; Karssemeijer, N.

    2017-01-01

    PURPOSE: Computer-aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated

  20. Reduction of false-positive recalls using a computerized mammographic image feature analysis scheme

    Science.gov (United States)

    Tan, Maxine; Pu, Jiantao; Zheng, Bin

    2014-08-01

    The high false-positive recall rate is one of the major dilemmas that significantly reduce the efficacy of screening mammography, which harms a large fraction of women and increases healthcare cost. This study aims to investigate the feasibility of helping reduce false-positive recalls by developing a new computer-aided diagnosis (CAD) scheme based on the analysis of global mammographic texture and density features computed from four-view images. Our database includes full-field digital mammography (FFDM) images acquired from 1052 recalled women (669 positive for cancer and 383 benign). Each case has four images: two craniocaudal (CC) and two mediolateral oblique (MLO) views. Our CAD scheme first computed global texture features related to the mammographic density distribution on the segmented breast regions of four images. Second, the computed features were given to two artificial neural network (ANN) classifiers that were separately trained and tested in a ten-fold cross-validation scheme on CC and MLO view images, respectively. Finally, two ANN classification scores were combined using a new adaptive scoring fusion method that automatically determined the optimal weights to assign to both views. CAD performance was tested using the area under a receiver operating characteristic curve (AUC). The AUC = 0.793  ±  0.026 was obtained for this four-view CAD scheme, which was significantly higher at the 5% significance level than the AUCs achieved when using only CC (p = 0.025) or MLO (p = 0.0004) view images, respectively. This study demonstrates that a quantitative assessment of global mammographic image texture and density features could provide useful and/or supplementary information to classify between malignant and benign cases among the recalled cases, which may eventually help reduce the false-positive recall rate in screening mammography.

  1. False-Positive TDxFLx urine Amphetamine/Metamphetamine II assay from Ofloxacin

    International Nuclear Information System (INIS)

    Nomier, Mahmoud A.; Al-Huseini, Hani K.

    2004-01-01

    Immunoassays are widely used in testing urine for illicit drugs. Ofloaxcin and a number of other quinolones were found to induce false-positive opiates (OP) urine immunoassays. This can result in misleading conclusions in the concept of drug abuse The aim of present study was to evaluate the effects of ofloxacin in theraputic doses on the induction of false-positive urine immunoassays for common drugs of abuse in healthy male volunteers. The study was conducted on 6 healthy male volunteers, aging between 35-45 years. Two doses of 400 mg ofloxacin each, were given orally to each volunteer at 12 hours interval and urine samples were collected before ofloaxcin administration and 5-7.5 hours after the second dose. Urine samples were subjected for OP, amphetamine/methamphetamine II (AM/MA II), cocaine and cannabinoids assays on TDxFLx analyzer. Ofloxacin produced significant increase (P cutoff) for AM/MA II assays, were found in all volunteers after ofloaxcin administration. The study recomends strongly the confirmation of positive urine immunoassay results for drugs of abuseby a more specific methodology e.g. gas chromatography/ mass spectroscopy (GC/MS). (author)

  2. Prenatal ultrasound screening: false positive soft markers may alter maternal representations and mother-infant interaction.

    Directory of Open Access Journals (Sweden)

    Sylvie Viaux-Savelon

    Full Text Available In up to 5% of pregnancies, ultrasound screening detects a "soft marker" (SM that places the foetus at risk for a severe abnormality. In most cases, prenatal diagnostic work-up rules out a severe defect. We aimed to study the effects of false positive SM on maternal emotional status, maternal representations of the infant, and mother-infant interaction.Utilizing an extreme-case prospective case control design, we selected from a group of 244 women undergoing ultrasound, 19 pregnant women whose foetus had a positive SM screening and a reassuring diagnostic work up, and 19 controls without SM matched for age and education. In the third trimester of pregnancy, within one week after delivery, and 2 months postpartum, we assessed anxiety, depression, and maternal representations. Mother-infant interactions were videotaped during feeding within one week after delivery and again at 2 months postpartum and coded blindly using the Coding Interactive Behavior (CIB scales. Anxiety and depression scores were significantly higher at all assessment points in the SM group. Maternal representations were also different between SM and control groups at all study time. Perturbations to early mother-infant interactions were observed in the SM group. These dyads showed greater dysregulation, lower maternal sensitivity, higher maternal intrusive behaviour and higher infant avoidance. Multivariate analysis showed that maternal representation and depression at third trimester predicted mother-infant interaction.False positive ultrasound screenings for SM are not benign and negatively affect the developing maternal-infant attachment. Medical efforts should be directed to minimize as much as possible such false diagnoses, and to limit their psychological adverse consequences.

  3. Center not liable for defamation from false-positive hepatitis test.

    Science.gov (United States)

    1997-04-18

    The Nebraska Court of Appeals ruled that [name removed] does not have a cause of action against the Lincoln Plasma Center in Lincoln, NE. The center blacklisted him as a carrier of hepatitis B virus; subsequent tests proved [name removed] was uninfected. [Name removed], a paid plasma donator, was placed on an ineligible list after he tested positive for the hepatitis B surface antigen. [Name removed] sued, alleging that Lincoln defamed him by publishing false information to blood banks about his eligibility to donate. The Court of Appeals upheld a trial court's directed verdict because there was no evidence that the plasma center acted in malice.

  4. Suture Granuloma Showing False-Positive Findings on FDG-PET

    Directory of Open Access Journals (Sweden)

    Kohei Takahara

    2013-01-01

    Full Text Available We report a case of a 33-year-old male with a mixed germ-cell testicular tumor. Postoperative follow-up FDG-PET revealed concentration of FDG in the left inguinal area which is not tumor metastasis or local recurrence but suture reactivity granuloma. In this paper, we reviewed suture granulomas associated with false-positive findings on FDG-PET after surgery. If FDG-PET will be used more frequently in the future, it will be necessary to refrain from using silk thread in order to prevent any unnecessary surgery.

  5. False positive indium-111 white blood cell scan in a closed clavicle fracture

    International Nuclear Information System (INIS)

    Friedman, R.J.; Gordon, L.

    1988-01-01

    Aggressive treatment of the multiply injured patient often requires early fixation of many fractures, some of which may be open. Often, patients develop postoperative fevers requiring a thorough workup to rule out infection. Recently, indium-111 white blood cell (WBC) imaging has become a valuable adjunct in the diagnosis of acute infection. The patient described had a simple, closed clavicle fracture with markedly increased activity on an indium-111 WBC scan obtained for fever workup. This subsequently proved to be a normal, healing, noninfected fracture by other diagnostic techniques. Noninfected, simple closed fractures should be added to the list of causes for a false-positive indium-111 WBC scan

  6. False-positive reduction in CAD mass detection using a competitive classification strategy

    International Nuclear Information System (INIS)

    Li Lihua; Zheng Yang; Zhang Lei; Clark, Robert A.

    2001-01-01

    High false-positive (FP) rate remains to be one of the major problems to be solved in CAD study because too many false-positively cued signals will potentially degrade the performance of detecting true-positive regions and increase the call-back rate in CAD environment. In this paper, we proposed a novel classification method for FP reduction, where the conventional 'hard' decision classifier is cascaded with a 'soft' decision classification with the objective to reduce false-positives in the cases with multiple FPs retained after the 'hard' decision classification. The 'soft' classification takes a competitive classification strategy in which only the 'best' ones are selected from the pre-classified suspicious regions as the true mass in each case. A neural network structure is designed to implement the proposed competitive classification. Comparative studies of FP reduction on a database of 79 images by a 'hard' decision classification and a combined 'hard'-'soft' classification method demonstrated the efficiency of the proposed classification strategy. For example, for the high FP sub-database which has only 31.7% of total images but accounts for 63.5% of whole FPs generated in single 'hard' classification, the FPs can be reduced for 56% (from 8.36 to 3.72 per image) by using the proposed method at the cost of 1% TP loss (from 69% to 68%) in whole database, while it can only be reduced for 27% (from 8.36 to 6.08 per image) by simply increasing the threshold of 'hard' classifier with a cost of TP loss as high as 14% (from 69% to 55%). On the average in whole database, the FP reduction by hybrid 'hard'-'soft' classification is 1.58 per image as compared to 1.11 by 'hard' classification at the TP costs described above. Because the cases with high dense tissue are of higher risk of cancer incidence and false-negative detection in mammogram screening, and usually generate more FPs in CAD detection, the method proposed in this paper will be very helpful in improving

  7. PIPIDA scintigraphy for cholecystitis: false positives in alcoholism and total parenteral nutrition

    International Nuclear Information System (INIS)

    Shuman, W.P.; Gibbs, P.; Rudd, T.G.; Mack, L.A.

    1982-01-01

    A review of gallbladder scintigraphy in patients with potentially compromised hepatobiliary function revealed two groups in whom cholecystitis might be mistakenly diagnosed. In 200 consecutive hospitalized patients studied with technetium-99m-PIPIDA for acute cholecystitis or cholestasis, there were 41 alcoholics and 17 patients on total parenteral nutrition. In 60% of the alcoholics and 92% of those on parenteral nutrition, absent or delayed visualization of the gallbladder occurred without physical or clinical evidence of cholecystitis. A cholecystagogue, sincalide, did not prevent the false-positive features which presumably are due to altered bile flow kinetics related to alcoholism and parenteral nutrition. Four patients on parenteral nutrition undergoing cholecystectomy for suspected cholecystitis had normal gallbladders filled with jellylike viscous thick bile. A positive (nonvisualized or delayed visualized) gallbladder PIPIDA scintigram in these two populations should not be interpreted as indicating a need for cholecystectomy

  8. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  9. False positive rate of carbon monoxide saturation by pulse oximetry of emergency department patients.

    Science.gov (United States)

    Weaver, Lindell K; Churchill, Susan K; Deru, Kayla; Cooney, Darryl

    2013-02-01

    Symptoms of carbon monoxide (CO) poisoning are non-specific. Diagnosis requires suspicion of exposure, confirmed by measuring ambient CO levels or carboxyhemoglobin (COHb). An FDA-approved pulse oximeter (Rad-57) can measure CO saturation (S(pCO)). The device accuracy has implications for clinical decision-making. From April 1 to August 15, 2008, study personnel measured S(pCO) and documented demographic factors at time of clinical blood draw, in a convenience sample of 1,363 subjects presenting to the emergency department at Intermountain Medical Center, Murray, Utah. The technician then assayed COHb. COHb and S(pCO) values were compared by subject; false positive or negative values were defined as S(pCO) at least 3 percentage points greater or less than COHb level, reported by the manufacturer to be ± 1 SD in performance. In 1,363 subjects, 613 (45%) were male, 1,141 (84%) were light-skinned, 14 in shock, 4 with CO poisoning, and 122 (9%) met the criteria for a false positive value (range 3-19 percentage points), while 247 (18%) met the criteria for a false negative value (-13 to -3 percentage points). Risks for a false positive S(pCO) reading included being female and having a lower perfusion index. Methemoglobin, body temperature, and blood pressure also appear to influence the S(pCO) accuracy. There was variability among monitors, possibly related to technician technique, as rotation of monitors among technicians was not enforced. While the Rad-57 pulse oximeter functioned within the manufacturer's specifications, clinicians using the Rad-57 should expect some S(pCO) readings to be significantly higher or lower than COHb measurements, and should not use S(pCO) to direct triage or patient management. An elevated S(pCO) could broaden the diagnosis of CO poisoning in patients with non-specific symptoms. However, a negative S(pCO) level in patients suspected of having CO poisoning should never rule out CO poisoning, and should always be confirmed by COHb. © 2013

  10. Reporting instructions significantly impact false positive rates when reading chest radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J. [The University of Sydney, Medical Image Optimisation and Perception Group, Discipline of Medical Radiation Sciences, Faculty of Health Sciences, Lidcombe, NSW (Australia)

    2016-10-15

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  11. A high false positive rate for Kepler planetary candidates of giant stars using asterodensity profiling

    International Nuclear Information System (INIS)

    Sliski, David H.; Kipping, David M.

    2014-01-01

    Asterodensity profiling (AP) is a relatively new technique for studying transit light curves. By comparing the mean stellar density derived from the transit light curve to that found through an independent method, AP provides information on several useful properties such as orbital eccentricity and blended light. We present an AP survey of 41 Kepler Objects of Interest (KOIs), with a single transiting candidate, for which the target star's mean stellar density has been measured using asteroseismology. The ensemble distribution of the AP measurements for the 31 dwarf stars in our sample shows excellent agreement with the spread expected if the KOIs were genuine and have realistic eccentricities. In contrast, the same test for the 10 giants in our sample reveals significant incompatibility at >4σ confidence. While extreme eccentricities could be invoked, this hypothesis requires four of the KOIs to contact their host star at periastron passage, including the recently claimed confirmation of Kepler-91b. After carefully examining several hypotheses, we conclude that the most plausible explanation is that the transiting objects orbit a different star to that measured with asteroseismology—cases we define as false-positives. Based on the AP distribution, we estimate a false-positive rate (FPR) for Kepler's giant stars with a single transiting object of FPR ≅ 70% ± 30%.

  12. Robust Correlation Analyses: False Positive and Power Validation Using a New Open Source Matlab Toolbox

    Science.gov (United States)

    Pernet, Cyril R.; Wilcox, Rand; Rousselet, Guillaume A.

    2012-01-01

    Pearson’s correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab(R) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand. PMID:23335907

  13. Reporting instructions significantly impact false positive rates when reading chest radiographs

    International Nuclear Information System (INIS)

    Robinson, John W.; Brennan, Patrick C.; Mello-Thoms, Claudia; Lewis, Sarah J.

    2016-01-01

    To determine the impact of specific reporting tasks on the performance of radiologists when reading chest radiographs. Ten experienced radiologists read a set of 40 postero-anterior (PA) chest radiographs: 21 nodule free and 19 with a proven solitary nodule. There were two reporting conditions: an unframed task (UFT) to report any abnormality and a framed task (FT) reporting only lung nodule/s. Jackknife free-response operating characteristic (JAFROC) figure of merit (FOM), specificity, location sensitivity and number of true positive (TP), false positive (FP), true negative (TN) and false negative (FN) decisions were used for analysis. JAFROC FOM for tasks showed a significant reduction in performance for framed tasks (P = 0.006) and an associated decrease in specificity (P = 0.011) but no alteration to the location sensitivity score. There was a significant increase in number of FP decisions made during framed versus unframed tasks for nodule-containing (P = 0.005) and nodule-free (P = 0.011) chest radiographs. No significant differences in TP were recorded. Radiologists report more FP decisions when given specific reporting instructions to search for nodules on chest radiographs. The relevance of clinical history supplied to radiologists is called into question and may induce a negative effect. (orig.)

  14. Robust correlation analyses: false positive and power validation using a new open source matlab toolbox.

    Science.gov (United States)

    Pernet, Cyril R; Wilcox, Rand; Rousselet, Guillaume A

    2012-01-01

    Pearson's correlation measures the strength of the association between two variables. The technique is, however, restricted to linear associations and is overly sensitive to outliers. Indeed, a single outlier can result in a highly inaccurate summary of the data. Yet, it remains the most commonly used measure of association in psychology research. Here we describe a free Matlab((R)) based toolbox (http://sourceforge.net/projects/robustcorrtool/) that computes robust measures of association between two or more random variables: the percentage-bend correlation and skipped-correlations. After illustrating how to use the toolbox, we show that robust methods, where outliers are down weighted or removed and accounted for in significance testing, provide better estimates of the true association with accurate false positive control and without loss of power. The different correlation methods were tested with normal data and normal data contaminated with marginal or bivariate outliers. We report estimates of effect size, false positive rate and power, and advise on which technique to use depending on the data at hand.

  15. False-positive results after environmental pinworm PCR testing due to Rhabditid nematodes in Corncob bedding.

    Science.gov (United States)

    Leblanc, Mathias; Berry, Kristina; Graciano, Sandy; Becker, Brandon; Reuter, Jon D

    2014-11-01

    Modern rodent colonies are housed in individually ventilated cages to protect the animals from contamination with adventitious pathogens. Standard health monitoring through soiled-bedding sentinels does not always detect infections, especially in the context of low pathogen prevalence. Recently proposed alternatives include analyzing environmental samples from the cages or rack exhaust by PCR to improve the detection of rodent pathogens but optimal sampling strategies have not yet been established for different microorganisms. Although generally very sensitive and specific, these molecular assays are not foolproof and subject to false-positive and -negative results and should always be interpreted cautiously with an overall understanding of the intrinsic controls and all the variables that may affect the results. Here, we report a limited Aspiculuris tetraptera outbreak in a mouse barrier facility that was detected by fecal PCR in sentinels and confirmed by fecal flotation and direct cecal examination of both sentinels and colony animals. The outbreak led to a widespread survey of all facilities for pinworms by using environmental PCR from ventilated rack exhaust plenums. Environmental PCR suggested an unexpected widespread contamination of all ventilated racks holding nonautoclaved cages, but results could not be confirmed in sentinel or colony animals by fecal flotation, cecal and colonic examination, or cage PCR testing. After additional investigation, the unexpected environmental PCR results were confirmed as false-positive findings due to the nonspecificity of the assay, leading to the amplification of rhabditid nematodes, which are not infectious in rodents but which contaminated the corncob bedding.

  16. Empirical methods for controlling false positives and estimating confidence in ChIP-Seq peaks

    Directory of Open Access Journals (Sweden)

    Courdy Samir J

    2008-12-01

    Full Text Available Abstract Background High throughput signature sequencing holds many promises, one of which is the ready identification of in vivo transcription factor binding sites, histone modifications, changes in chromatin structure and patterns of DNA methylation across entire genomes. In these experiments, chromatin immunoprecipitation is used to enrich for particular DNA sequences of interest and signature sequencing is used to map the regions to the genome (ChIP-Seq. Elucidation of these sites of DNA-protein binding/modification are proving instrumental in reconstructing networks of gene regulation and chromatin remodelling that direct development, response to cellular perturbation, and neoplastic transformation. Results Here we present a package of algorithms and software that makes use of control input data to reduce false positives and estimate confidence in ChIP-Seq peaks. Several different methods were compared using two simulated spike-in datasets. Use of control input data and a normalized difference score were found to more than double the recovery of ChIP-Seq peaks at a 5% false discovery rate (FDR. Moreover, both a binomial p-value/q-value and an empirical FDR were found to predict the true FDR within 2–3 fold and are more reliable estimators of confidence than a global Poisson p-value. These methods were then used to reanalyze Johnson et al.'s neuron-restrictive silencer factor (NRSF ChIP-Seq data without relying on extensive qPCR validated NRSF sites and the presence of NRSF binding motifs for setting thresholds. Conclusion The methods developed and tested here show considerable promise for reducing false positives and estimating confidence in ChIP-Seq data without any prior knowledge of the chIP target. They are part of a larger open source package freely available from http://useq.sourceforge.net/.

  17. False-positive ethyl glucuronide immunoassay screening caused by a propyl alcohol-based hand sanitizer.

    Science.gov (United States)

    Arndt, Torsten; Grüner, Joachim; Schröfel, Stefanie; Stemmerich, Karsten

    2012-11-30

    Urine ethyl glucuronide (EtG) is considered as a specific marker of recent ethanol consumption. We describe false-positive DRI(®) EIA EtG enzyme immunoassay results caused by propyl glucuronides in urine after using a propanol-based hand sanitizer. EtG screening was done with the DRI(®) EIA EtG assay (Microgenics), using a cut-off of 0.5 mg/L as recommended by the manufacturer and of 0.1 mg/L as demanded by the German Regulations for Reissuing Drivers Licenses. Confirmatory EtG analysis was done with the ClinMass(®) EtG LC-MS/MS testkit (Recipe), extended by the mass transitions 235.1→75.1, 235.1→85.1, and 235.1→113.1 for the detection of the 1- and 2-propyl glucuronides. Self-experiments were done by staff members of our lab (n=7), using 3 mL Sterillium(®) Classic Pure (30 g/100 g 1-propanol and 45 g/100 g 2-propanol) for hand sanitation every quarter of an hour for 8 h according to DIN EN 1500:2011-05 with and without an exhauster and by passive inhalation of the sanitizer vapor. Spot urine samples were taken immediately before and up to 24 h after the first sanitizer use. False-positive immunoassay results of up to 4 mg/L or 2.3 mg/g creatinine were obtained after normal use of the sanitizer and also after passive inhalation of the sanitizer vapor (up to 0.89 mg/L or 0.61 mg/g). Immunoassay results were positive even after 4-fold use of the sanitizer (up to 0.14 mg/L or 0.38 mg/g) and up to 6 h after the last sanitizer contact (maximum 0.63 mg/L and 0.33 mg/g for sanitizer users and 0.25 mg/g after passive inhalation). Spiking of EtG-free urine with 1-propyl glucuronide (Athena Environmental Sciences) between 0.05 and 10 mg/L clearly demonstrated a cross reaction of the immunoassay of approx. 10% as compared to EtG. LC-MS/MS of urines with a positive immunoassay EtG result did not show EtG signals, but distinct signals of 1-propyl glucuronide (n-propyl glucuronide) and 2-propyl glucuronide (iso-propyl glucuronide). An exhauster effectively prevented

  18. Using ELISPOT to expose false positive skin test conversion in tuberculosis contacts.

    Directory of Open Access Journals (Sweden)

    Philip C Hill

    2007-01-01

    Full Text Available Repeat tuberculin skin tests may be false positive due to boosting of waned immunity to past mycobacterial exposure. We evaluated whether an ELISPOT test could identify tuberculosis (TB contacts with boosting of immunity to non-tuberculous mycobacterial exposure.We conducted tuberculin and ELISPOT tests in 1665 TB contacts: 799 were tuberculin test negative and were offered a repeat test after three months. Those with tuberculin test conversion had an ELISPOT, chest X-ray and sputum analysis if appropriate. We compared converters with non-converters, assessed the probability of each of four combinations of ELISPOT results over the two time points and estimated boosting with adjustment for ELISPOT sensitivity and specificity. 704 (72% contacts had a repeat tuberculin test; 176 (25% had test conversion, which increased with exposure to a case (p = 0.002, increasing age (p = 0.0006 and BCG scar (p = 0.06. 114 tuberculin test converters had ELISPOT results: 16(14% were recruitment positive/follow-up positive, 9 (8% positive/negative, 34 (30% negative/positive, and 55 (48% were negative/negative. There was a significant non-linear effect of age for ELISPOT results in skin test converters (p = 0.038. Estimates of boosting ranged from 32%-41% of skin test converters with increasing age. Three converters were diagnosed with TB, two had ELISPOT results: both were positive, including one at recruitment.We estimate that approximately one third of tuberculin skin test conversion in Gambian TB case contacts is due to boosting of immunity to non-tuberculous mycobacterial exposure. Further longitudinal studies are required to confirm whether ELISPOT can reliably identify case contacts with tuberculin test conversion that would benefit most from prophylactic treatment.

  19. Inflammatory disorders mimicking periprosthetic joint infections may result in false positive α-defensin.

    Science.gov (United States)

    Plate, Andreas; Stadler, Laura; Sutter, Reto; Anagnostopoulos, Alexia; Frustaci, Dario; Zbinden, Reinhard; Fucentese, Sandro F; Zinkernagel, Annelies S; Zingg, Patrick O; Achermann, Yvonne

    2018-02-26

    The antimicrobial peptide α-defensin has recently been introduced as potential "single" biomarker with a high sensitivity and specificity for the preoperative diagnosis of periprosthetic joint infections (PJIs). However, most studies assessed the benefits of the test with exclusion of patients with rheumatic diseases. We aimed to evaluate the α-defensin test in a cohort study without exclusion of cases with inflammatory diseases. Between June 2016 and June 2017, we prospectively included cases with a suspected PJI and an available lateral flow test α-defensin (Synovasure®) in synovial fluid. We compared the test result to the diagnostic criteria for PJIs published by an International Consensus Group in 2013. We included 109 cases (49 hips, 60 knees) in which preoperative α-defensin tests had been performed. Thereof, 20 PJIs (16 hips, 4 knees) were diagnosed. Preoperative α-defensin tests were positive in 25 cases (22.9%) with a test sensitivity and specificity of 90% and 92.1% (95% confidence interval [CI], 68.3 - 98.8% and 84.5 - 96.8%, respectively), and a high negative predictive value of 97.6% (95% CI, 91.7 - 99.4%). We interpreted seven α-defensin tests as false positive, mainly in cases with inflammatory rheumatic diseases, including crystal deposition diseases. A negative synovial α-defensin test can reliably rule out a PJI. However, the test can be false positive in conjunction with an underlying non-infectious inflammatory disease. We therefore propose to use the α-defensin test only in addition to MSIS criteria and assessment for crystals in synovial aspirates. Copyright © 2018. Published by Elsevier Ltd.

  20. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Directory of Open Access Journals (Sweden)

    Yamaguchi Rin

    2012-05-01

    Full Text Available Abstract Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases, to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6% cases were benign, including mastopathy (fibrocystic disease in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9% cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC being significantly more frequent (49.5% than papillotubular growing type (Papi-tub (P P = 0.0001 and ductal carcinoma in situ (DCIS (P = 0.0001. Among 458 indeterminate cases, 54/139 (38.8% were histologically benign (mastopathy, 30.0%; fibroadenoma, 27.8%; papilloma, 26.0% and 73/139 (52.5% were malignant, with SIDC being the most frequent malignant tumor (37.0%. Among 52 false-negative cases, SIDC was significantly more frequent (42.3% than DCIS (P = 0.0049 and Papi-tub (P = 0.001. There were three false-positive cases, with one each of fibroadenoma, epidermal cyst and papilloma. Conclusions The inadequate, indeterminate, false-negative and false-positive cases showed similar histological types, notably SIDC for malignant tumors, and mastopathy, fibroadenoma and papilloma for

  1. Prime time news: the influence of primed positive and negative emotion on susceptibility to false memories.

    Science.gov (United States)

    Porter, Stephen; ten Brinke, Leanne; Riley, Sean N; Baker, Alysha

    2014-01-01

    We examined the relation between emotion and susceptibility to misinformation using a novel paradigm, the ambiguous stimuli affective priming (ASAP) paradigm. Participants (N = 88) viewed ambiguous neutral images primed either at encoding or retrieval to be interpreted as either highly positive or negative (or neutral/not primed). After viewing the images, they either were asked misleading or non-leading questions. Following a delay, memory accuracy for the original images was assessed. Results indicated that any emotional priming at encoding led to a higher susceptibility to misinformation relative to priming at recall. In particular, inducing a negative interpretation of the image at encoding led to an increased susceptibility of false memories for major misinformation (an entire object not actually present in the scene). In contrast, this pattern was reversed when priming was used at recall; a negative reinterpretation of the image decreased memory distortion relative to unprimed images. These findings suggest that, with precise experimental control, the experience of emotion at event encoding, in particular, is implicated in false memory susceptibility.

  2. Improved accuracy of cell surface shaving proteomics in Staphylococcus aureus using a false-positive control

    DEFF Research Database (Denmark)

    Solis, Nestor; Larsen, Martin Røssel; Cordwell, Stuart J

    2010-01-01

    Proteolytic treatment of intact bacterial cells is an ideal means for identifying surface-exposed peptide epitopes and has potential for the discovery of novel vaccine targets. Cell stability during such treatment, however, may become compromised and result in the release of intracellular proteins...... that complicate the final analysis. Staphylococcus aureus is a major human pathogen, causing community and hospital-acquired infections, and is a serious healthcare concern due to the increasing prevalence of multiple antibiotic resistances amongst clinical isolates. We employed a cell surface "shaving" technique...... to trypsin and three identified in the control. The use of a subtracted false-positive strategy improved enrichment of surface-exposed peptides in the trypsin data set to approximately 80% (124/155 peptides). Predominant surface proteins were those associated with methicillin resistance-surface protein SACOL...

  3. Factors associated with false-positive self-reported adherence to antihypertensive drugs.

    Science.gov (United States)

    Tedla, Y G; Bautista, L E

    2017-05-01

    Self-reported medication adherence is known to overestimate true adherence. However, little is known about patient factors that may contribute to the upward bias in self-reported medication adherence. The objective of this study is to examine whether demographic, behavioral, medication and mood factors are associated with being a false-positive self-reported adherer (FPA) to antihypertensive drug treatment. We studied 175 patients (mean age: 50 years; 57% men) from primary-care clinics starting antihypertensive drug treatment. Self-reported adherence (SRA) was measured with the Medication Adherence Report Scale (MARS) and by the number of drug doses missed in the previous week/month, and compared with pill count adherence ratio (PCAR) as gold standard. Data on adherence, demographic, behavioral, medication and mood factors were collected at baseline and every 3 months up to 1 year. FPA was defined as being a non-adherer by PCAR and an adherer by self-report. Mixed effect logistic regression was used for the analysis. Twenty percent of participants were FPA. Anxiety increased (odds ratio (OR): 3.00; P=0.01), whereas smoking (OR: 0.40; P=0.03) and drug side effects (OR: 0.46, P=0.03) decreased the probability for FPA by MARS. Education below high-school completion increased the probability of being an FPA as measured by missing doses in the last month (OR: 1.66; P=0.04) and last week (OR: 1.88; P=0.02). The validity of SRA varies significantly according to drug side effects, behavioral factors and patient's mood. Careful consideration should be given to the use of self-reported measures of adherence among patients likely to be false-positive adherers.

  4. A FALSE POSITIVE FOR OCEAN GLINT ON EXOPLANETS: THE LATITUDE-ALBEDO EFFECT

    International Nuclear Information System (INIS)

    Cowan, Nicolas B.; Abbot, Dorian S.; Voigt, Aiko

    2012-01-01

    Identifying liquid water on the surface of planets is a high priority, as this traditionally defines habitability. One proposed signature of oceans is specular reflection ('glint'), which increases the apparent albedo of a planet at crescent phases. We post-process a global climate model of an Earth-like planet to simulate reflected light curves. Significantly, we obtain glint-like phase variations even though we do not include specular reflection in our model. This false positive is the product of two generic properties: (1) for modest obliquities, a planet's poles receive less orbit-averaged stellar flux than its equator, so the poles are more likely to be covered in highly reflective snow and ice; and (2) we show that reflected light from a modest-obliquity planet at crescent phases probes higher latitudes than at gibbous phases, therefore a planet's apparent albedo will naturally increase at crescent phase. We suggest that this 'latitude-albedo effect' will operate even for large obliquities: in that case the equator receives less orbit-averaged flux than the poles, and the equator is preferentially sampled at crescent phase. Using rotational and orbital color variations to map the surfaces of directly imaged planets and estimate their obliquity will therefore be a necessary pre-condition for properly interpreting their reflected phase variations. The latitude-albedo effect is a particularly convincing glint false positive for zero-obliquity planets, and such worlds are not amenable to latitudinal mapping. This effect severely limits the utility of specular reflection for detecting oceans on exoplanets.

  5. PRE-SPECTROSCOPIC FALSE-POSITIVE ELIMINATION OF KEPLER PLANET CANDIDATES

    International Nuclear Information System (INIS)

    Batalha, Natalie M.; Rowe, Jason F.; Borucki, William J.; Koch, David G.; Lissauer, Jack J.; Gilliland, Ronald L.; Jenkins, Jon J.; Caldwell, Douglas; Dunham, Edward W.; Gautier, Thomas N.; Howell, Steve B.; Latham, David W.; Marcy, Geoff W.; Prsa, Andrej

    2010-01-01

    Ten days of commissioning data (Quarter 0) and 33 days of science data (Quarter 1) yield instrumental flux time series of ∼150,000 stars that were combed for transit events, termed threshold crossing events(TCE), each having a total detection statistic above 7.1σ. TCE light curves are modeled as star+planet systems. Those returning a companion radius smaller than 2R J are assigned a Kepler Object of Interest (KOI) number. The raw flux, pixel flux, and flux-weighted centroids of every KOI are scrutinized to assess the likelihood of being an astrophysical false positive versus the likelihood of being a planetary companion. This vetting using Kepler data is referred to as data validation (DV). Herein, we describe the DV metrics and graphics used to identify viable planet candidates amongst the KOIs. Light curve modeling tests for (1) the difference in depth of the odd- versus even-numbered transits, (2) evidence of ellipsoidal variations, and (3) evidence of a secondary eclipse event at phase = 0.5. Flux-weighted centroids are used to test for signals correlated with transit events with a magnitude and direction indicative of a background eclipsing binary. Centroid time series are complimented by analysis of images taken in-transit versus out-of-transit, the difference often revealing the pixel contributing the most to the flux change during transit. Examples are shown to illustrate each test. Candidates passing DV are submitted to ground-based observers for further false-positive elimination or confirmation/characterization.

  6. Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI

    International Nuclear Information System (INIS)

    Padhani, Anwar R.; Khoo, Vincent S.; Suckling, John; Husband, Janet E.; Leach, Martin O.; Dearnaley, David P.

    1999-01-01

    Purpose: To evaluate the dynamic interrelationship between rectal distension and rectal movements, and to determine the effect of rectal movement on the position of the prostatic gland using cine magnetic resonance imaging (MRI). Methods and Materials: Fifty-five patients with biopsy-proven or suspected prostate cancer were examined in the axial plane using repeated spoiled gradient-echo sequences every 10 seconds for 7 minutes. Twenty-four patients received bowel relaxants before imaging. Images were analyzed for the degree of rectal distension, for the incidence, magnitude, and number of rectal and prostate movements. Results: Rectal movements were seen in 28 (51%) patients overall, in 10 (42%) of those receiving bowel relaxants and in 18 (58%) not receiving bowel relaxants. The incidence of rectal movements correlated with the degree of rectal distension (p = 0.0005), but the magnitude of rectal movements did not correlate with the degree of rectal distension. Eighty-six rectal movements resulting in 33 anterior-posterior (AP) prostate movements were seen. The magnitude of rectal movements correlated well with degree of prostate movements (p < 0.001). Prostate movements in the AP direction were seen in 16 (29%) patients, and in 9 (16%) patients the movement was greater than 5 mm. The median prostate AP displacement was anterior by 4.2 (-5 to +14 mm). Conclusions: Cine MRI is able to demonstrate near real time rectal and associated prostate movements. Rectal movements are related to rectal distension and result in significant displacements of the prostate gland over a time period similar to that used for daily fractionated radiotherapy treatments. Delivery of radiotherapy needs to take into account these organ movements

  7. Are Hemorrhoids Associated with False-Positive Fecal Immunochemical Test Results?

    Science.gov (United States)

    Kim, Nam Hee; Park, Jung Ho; Park, Dong Il; Sohn, Chong Il; Choi, Kyuyong; Jung, Yoon Suk

    2017-01-01

    False-positive (FP) results of fecal immunochemical tests (FITs) conducted in colorectal cancer (CRC) screening could lead to performing unnecessary colonoscopies. Hemorrhoids are a possible cause of FP FIT results; however, studies on this topic are extremely rare. We investigated whether hemorrhoids are associated with FP FIT results. A retrospective study was conducted at a university hospital in Korea from June 2013 to May 2015. Of the 34547 individuals who underwent FITs, 3946 aged ≥50 years who underwent colonoscopies were analyzed. Logistic regression analysis was performed to determine factors associated with FP FIT results. Among 3946 participants, 704 (17.8%) showed positive FIT results and 1303 (33.0%) had hemorrhoids. Of the 704 participants with positive FIT results, 165 had advanced colorectal neoplasia (ACRN) and 539 had no ACRN (FP results). Of the 1303 participants with hemorrhoids, 291 showed FP results, of whom 81 showed FP results because of hemorrhoids only. Participants with hemorrhoids had a higher rate of FP results than those without hemorrhoids (291/1176, 24.7% vs. 248/2361, 10.5%; phemorrhoids as the only abnormality had a higher rate of FP results than those experiencing no such abnormalities (81/531, 15.3% vs. 38/1173, 3.2%; phemorrhoids was identified as an independent predictor of FP results (adjusted odds ratio, 2.76; 95% confidence interval, 2.24-3.40; pHemorrhoids are significantly associated with FP FIT results. Their presence seemed to be a non-negligible contributor of FP results in FIT-based CRC screening programs.

  8. Breast cancer risk is increased in the years following false-positive breast cancer screening.

    Science.gov (United States)

    Goossens, Mathijs C; De Brabander, Isabel; De Greve, Jacques; Vaes, Evelien; Van Ongeval, Chantal; Van Herck, Koen; Kellen, Eliane

    2017-09-01

    A small number of studies have investigated breast cancer (BC) risk among women with a history of false-positive recall (FPR) in BC screening, but none of them has used time-to-event analysis while at the same time quantifying the effect of false-negative diagnostic assessment (FNDA). FNDA occurs when screening detects BC, but this BC is missed on diagnostic assessment (DA). As a result of FNDA, screenings that detected cancer are incorrectly classified as FPR. Our study linked data recorded in the Flemish BC screening program (women aged 50-69 years) to data from the national cancer registry. We used Cox proportional hazards models on a retrospective cohort of 298 738 women to assess the association between FPR and subsequent BC, while adjusting for potential confounders. The mean follow-up was 6.9 years. Compared with women without recall, women with a history of FPR were at an increased risk of developing BC [hazard ratio=2.10 (95% confidence interval: 1.92-2.31)]. However, 22% of BC after FPR was due to FNDA. The hazard ratio dropped to 1.69 (95% confidence interval: 1.52-1.87) when FNDA was excluded. Women with FPR have a subsequently increased BC risk compared with women without recall. The risk is higher for women who have a FPR BI-RADS 4 or 5 compared with FPR BI-RADS 3. There is room for improvement of diagnostic assessment: 41% of the excess risk is explained by FNDA after baseline screening.

  9. Frequency and position of pineal gland calcification in a Japanese population

    Energy Technology Data Exchange (ETDEWEB)

    Hattori, Fumio; Ishimaru, Toranosuke; Russell, W J; Kogure, Takashi

    1964-04-23

    A review of all skull roentgenograms of 525 normal patients was conducted to determine the incidence of pineal gland and habenular nucleus calcification, and to compile normal values for pineal gland calcification in a Japanese population. These data are presented as tables and graphs for use in roentgenological interpretation. 17 references, 2 figures, 5 tables.

  10. Computer-Aided Detection in Digital Mammography: False-Positive Marks and Their Reproducibility in Negative Mammograms

    International Nuclear Information System (INIS)

    Kim, Seung Ja; Moon, Woo Kyung; Cho, Nariya; Chang, Jung Min; Seong, Min Hyun

    2009-01-01

    Background: There are relatively few studies reporting the frequency of false-positive computer-aided detection (CAD) marks and their reproducibility in normal cases. Purpose: To evaluate retrospectively the false-positive mark rate of a CAD system and the reproducibility of false-positive marks in two sets of negative digital mammograms. Material and Methods: Two sets of negative digital mammograms were obtained in 360 women (mean age 57 years, range 30-76 years) with an approximate interval of 1 year (mean time 343.7 days), and a CAD system was applied. False-positive CAD marks and the reproducibility were determined. Results: Of the 360 patients, 252 (70.0%) and 240 (66.7%) patients had 1-7 CAD marks on the initial and second mammograms, respectively. The false-positive CAD mark rate was 1.5 (1.1 for masses and 0.4 for calcifications) and 1.4 (1.0 for masses and 0.4 for calcifications) per examination in the initial and second mammograms, respectively. The reproducibility of the false-positive CAD marks was 12.0% for both mass (81/680) and microcalcification (33/278) marks. Conclusion: False-positive CAD marks were seen in approximately 70% of normal cases. However, the reproducibility was very low. Radiologists must be familiar with the findings of false-positive CAD marks, since they are very common and can increase the recall rate in screening

  11. Parental knowledge reduces long term anxiety induced by false-positive test results after newborn screening for cystic fibrosis

    NARCIS (Netherlands)

    Vernooij-van Langen, A.M.M.; Pal, S.M. van der; Reijntjens, A.J.T.; Loeber, J.G.; Dompeling, E.; Dankert-Roelse, J.E.

    2014-01-01

    Background: False-positive screening results in newborn screening for cystic fibrosis may lead to parental stress, family relationship problems and a changed perception of the child's health. Aim of the study: To evaluate whether parental anxiety induced by a false positive screening result

  12. Detecting and avoiding likely false-positive findings - a practical guide.

    Science.gov (United States)

    Forstmeier, Wolfgang; Wagenmakers, Eric-Jan; Parker, Timothy H

    2017-11-01

    Recently there has been a growing concern that many published research findings do not hold up in attempts to replicate them. We argue that this problem may originate from a culture of 'you can publish if you found a significant effect'. This culture creates a systematic bias against the null hypothesis which renders meta-analyses questionable and may even lead to a situation where hypotheses become difficult to falsify. In order to pinpoint the sources of error and possible solutions, we review current scientific practices with regard to their effect on the probability of drawing a false-positive conclusion. We explain why the proportion of published false-positive findings is expected to increase with (i) decreasing sample size, (ii) increasing pursuit of novelty, (iii) various forms of multiple testing and researcher flexibility, and (iv) incorrect P-values, especially due to unaccounted pseudoreplication, i.e. the non-independence of data points (clustered data). We provide examples showing how statistical pitfalls and psychological traps lead to conclusions that are biased and unreliable, and we show how these mistakes can be avoided. Ultimately, we hope to contribute to a culture of 'you can publish if your study is rigorous'. To this end, we highlight promising strategies towards making science more objective. Specifically, we enthusiastically encourage scientists to preregister their studies (including a priori hypotheses and complete analysis plans), to blind observers to treatment groups during data collection and analysis, and unconditionally to report all results. Also, we advocate reallocating some efforts away from seeking novelty and discovery and towards replicating important research findings of one's own and of others for the benefit of the scientific community as a whole. We believe these efforts will be aided by a shift in evaluation criteria away from the current system which values metrics of 'impact' almost exclusively and towards a system

  13. False Positive Uptake in Bilateral Gynecomastia on 68Ga-PSMA PET/CT Scan.

    Science.gov (United States)

    Sasikumar, Arun; Joy, Ajith; Nair, Bindu P; Pillai, M R A; Madhavan, Jayaprakash

    2017-09-01

    A 66-year-old man on hormonal therapy with prostate cancer was referred for Ga-PSMA PET/CT scan for biochemical recurrence. Ga-PSMA PET/CT scan detected moderate heterogeneous tracer concentration in bilateral breast parenchyma, in addition to the abnormal tracer concentration in enlarged prostate gland, right external iliac lymph node, and sclerotic lesion in L4 vertebra. On clinical examination, he was found to have bilateral gynecomastia. Abnormal concentration of Ga-PSMA in breast cancer is now well known, and in this context, it is important to know that tracer localization can occur in gynecomastia as well, as evidenced in this case.

  14. Evaluation of inadequate, indeterminate, false-negative and false-positive cases in cytological examination for breast cancer according to histological type

    Science.gov (United States)

    2012-01-01

    Background We previously investigated the current status of breast cytology cancer screening at seven institutes in our area of southern Fukuoka Prefecture, and found some differences in diagnostic accuracy among the institutions. In the present study, we evaluated the cases involved and noted possible reasons for their original cytological classification as inadequate, indeterminate, false-negative and false-positive according to histological type. Methods We evaluated the histological findings in 5693 individuals who underwent cytological examination for breast cancer (including inadequate, indeterminate, false-negative and false-positive cases), to determine the most common histological types and/or features in these settings and the usefulness/limitations of cytological examination for the diagnosis of breast cancer. Results Among 1152 cytologically inadequate cases, histology revealed that 75/173 (43.6%) cases were benign, including mastopathy (fibrocystic disease) in 38.6%, fibroadenoma in 24.0% and papilloma in 5.3%. Ninety-five of 173 (54.9%) cases were histologically malignant, with scirrhous growing type, invasive ductal carcinoma (SIDC) being significantly more frequent (49.5%) than papillotubular growing type (Papi-tub) (P breast disease. In particular, several inadequate, indeterminate and false-negative cases with samples collected by aspiration were diagnosed as SIDC. These findings should encourage the use of needle biopsy rather than aspiration when this histological type is identified on imaging. Namely, good communication between clinicians and pathological staff, and triple assessment (i.e., clinical, pathological and radiological assessment), are important for accurate diagnosis of aspiration samples. Virtual slides The virtual slide(s) for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/7349809170055423 PMID:22607447

  15. Mammography Clinical Image Quality and the False Positive Rate in a Canadian Breast Cancer Screening Program.

    Science.gov (United States)

    Guertin, Marie-Hélène; Théberge, Isabelle; Zomahoun, Hervé Tchala Vignon; Dufresne, Michel-Pierre; Pelletier, Éric; Brisson, Jacques

    2018-05-01

    The study sought to determine if mammography quality is associated with the false positive (FP) rate in the Quebec breast cancer screening program in 2004 and 2005. Mammography quality of a random sample of screen-film mammograms was evaluated by an expert radiologist following the criteria of the Canadian Association of Radiologists. For each screening examination, scores ranging from 1 (poor quality) to 5 (excellent quality) were attributed for positioning, compression, contrast, exposure level, sharpness, and artifacts. A final overall quality score (lower or higher) was also given. Poisson regression models with robust estimation of variance and adjusted for potential confounding factors were used to assess associations of mammography quality with the FP rate. Among 1,209 women without cancer, there were 104 (8.6%) FPs. Lower overall mammography quality is associated with an increase in the FP rate (risk ratio [RR], 1.4; 95% confidence interval [CI], 1.0-2.1; P = .07) but this increase was not statistically significant. Artifacts were associated with an increase in the FP rate (RR, 2.1; 95% CI, 1.3-3.3; P = .01) whereas lower quality of exposure level was related to a reduction of the FP rate (RR, 0.4; 95% CI, 0.1-1.0; P = .01). Lower quality scores for all other quality attributes were related to a nonstatistically significant increase in the FP rate of 10%-30%. Artifacts can have a substantial effect on the FP rate. The effect of overall mammography quality on the FP rate may also be substantial and needs to be clarified. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  16. False positive results using calcitonin as a screening method for medullary thyroid carcinoma

    Directory of Open Access Journals (Sweden)

    Rafael Loch Batista

    2013-01-01

    Full Text Available The role of serum calcitonin as part of the evaluation of thyroid nodules has been widely discussed in literature. However there still is no consensus of measurement of calcitonin in the initial evaluation of a patient with thyroid nodule. Problems concerning cost-benefit, lab methods, false positive and low prevalence of medullary thyroid carcinoma (MTC are factors that limit this approach. We have illustrated two cases where serum calcitonin was used in the evaluation of thyroid nodule and rates proved to be high. A stimulation test was performed, using calcium as secretagogue, and calcitonin hyper-stimulation was confirmed, but anatomopathologic examination did not evidence medullar neoplasia. Anatomopathologic diagnosis detected Hashimoto thyroiditis in one case and adenomatous goiter plus an occult papillary thyroid carcinoma in the other one. Recommendation for routine use of serum calcitonin in the initial diagnostic evaluation of a thyroid nodule, followed by a confirming stimulation test if basal serum calcitonin is showed to be high, is the most currently recommended approach, but questions concerning cost-benefit and possibility of diagnosis error make the validity of this recommendation discussible.

  17. The uterine blush. A potential false-positive in Meckel's scan interpretation

    International Nuclear Information System (INIS)

    Fink-Bennett, D.

    1982-01-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations

  18. THE POSSIBLE MOON OF KEPLER-90g IS A FALSE POSITIVE

    Energy Technology Data Exchange (ETDEWEB)

    Kipping, D. M.; Torres, G.; Buchhave, L. A. [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); Huang, X.; Bakos, G. Á. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 05844 (United States); Nesvorný, D. [Department of Space Studies, Southwest Research Institute, 1050 Walnut Street, Suite 300, Boulder, CO 80302 (United States); Schmitt, A. R., E-mail: dkipping@cfa.harvard.edu

    2015-01-20

    The discovery of an exomoon would provide deep insights into planet formation and the habitability of planetary systems, with transiting examples being particularly sought after. Of the hundreds of Kepler planets now discovered, the seven-planet system Kepler-90 is unusual for exhibiting an unidentified transit-like signal in close proximity to one of the transits of the long-period gas-giant Kepler-90g, as noted by Cabrera et al. As part of the ''Hunt for Exomoons with Kepler'' project, we investigate this possible exomoon signal and find it passes all conventional photometric, dynamical, and centroid diagnostic tests. However, pixel-level light curves indicate that the moon-like signal occurs on nearly all of the target's pixels, which we confirm using a novel way of examining pixel-level data which we dub the ''transit centroid''. This test reveals that the possible exomoon to Kepler-90g is likely a false positive, perhaps due to a cosmic ray induced sudden pixel sensitivity dropout. This work highlights the extreme care required for seeking non-periodic low-amplitude transit signals, such as exomoons.

  19. The uterine blush. A potential false-positive in Meckel's scan interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Fink-Bennett, D.

    1982-10-01

    To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. Two with irregular periods, and one with no recorded menstrual history, manifested the blush. Radiotracer should be expected in the uterus during the menstrual and secretory phases of the menstrual cycle. It is a manifestation of a normal physiologic phenomenon, and must be recognized to prevent false-positive Meckel's scan interpretations.

  20. Limited agreement of independent RNAi screens for virus-required host genes owes more to false-negative than false-positive factors.

    Directory of Open Access Journals (Sweden)

    Linhui Hao

    Full Text Available Systematic, genome-wide RNA interference (RNAi analysis is a powerful approach to identify gene functions that support or modulate selected biological processes. An emerging challenge shared with some other genome-wide approaches is that independent RNAi studies often show limited agreement in their lists of implicated genes. To better understand this, we analyzed four genome-wide RNAi studies that identified host genes involved in influenza virus replication. These studies collectively identified and validated the roles of 614 cell genes, but pair-wise overlap among the four gene lists was only 3% to 15% (average 6.7%. However, a number of functional categories were overrepresented in multiple studies. The pair-wise overlap of these enriched-category lists was high, ∼19%, implying more agreement among studies than apparent at the gene level. Probing this further, we found that the gene lists implicated by independent studies were highly connected in interacting networks by independent functional measures such as protein-protein interactions, at rates significantly higher than predicted by chance. We also developed a general, model-based approach to gauge the effects of false-positive and false-negative factors and to estimate, from a limited number of studies, the total number of genes involved in a process. For influenza virus replication, this novel statistical approach estimates the total number of cell genes involved to be ∼2,800. This and multiple other aspects of our experimental and computational results imply that, when following good quality control practices, the low overlap between studies is primarily due to false negatives rather than false-positive gene identifications. These results and methods have implications for and applications to multiple forms of genome-wide analysis.

  1. Effect of radiologist experience on the risk of false-positive results in breast cancer screening programs

    International Nuclear Information System (INIS)

    Zubizarreta Alberdi, Raquel; Llanes, Ana B.F.; Ortega, Raquel Almazan; Exposito, Ruben Roman; Collado, Jose M.V.; Oliveres, Xavier Castells; Queiro Verdes, Teresa; Natal Ramos, Carmen; Sanz, Maria Ederra; Salas Trejo, Dolores

    2011-01-01

    To evaluate the effect of radiologist experience on the risk of false-positive results in population-based breast cancer screening programmes. We evaluated 1,440,384 single-read screening mammograms, corresponding to 471,112 women aged 45-69 years participating in four Spanish programmes between 1990 and 2006. The mammograms were interpreted by 72 radiologists. The overall percentage of false-positive results was 5.85% and that for false-positives resulting in an invasive procedure was 0.38%. Both the risk of false-positives overall and of false-positives leading to an invasive procedure significantly decreased (p 14,999 mammograms with respect to the reference category (<500). The risk of both categories of false-positives was also significantly reduced (p < 0.001) as radiologists' years of experience increased: OR 0.96 and OR 0.84, respectively, for 1 year's experience and OR 0.72 and OR 0.73, respectively, for more than 4 years' experience with regard to the category of <1 year's experience. Radiologist experience is a determining factor in the risk of a false-positive result in breast cancer screening. (orig.)

  2. Mouse obesity network reconstruction with a variational Bayes algorithm to employ aggressive false positive control

    Directory of Open Access Journals (Sweden)

    Logsdon Benjamin A

    2012-04-01

    Full Text Available Abstract Background We propose a novel variational Bayes network reconstruction algorithm to extract the most relevant disease factors from high-throughput genomic data-sets. Our algorithm is the only scalable method for regularized network recovery that employs Bayesian model averaging and that can internally estimate an appropriate level of sparsity to ensure few false positives enter the model without the need for cross-validation or a model selection criterion. We use our algorithm to characterize the effect of genetic markers and liver gene expression traits on mouse obesity related phenotypes, including weight, cholesterol, glucose, and free fatty acid levels, in an experiment previously used for discovery and validation of network connections: an F2 intercross between the C57BL/6 J and C3H/HeJ mouse strains, where apolipoprotein E is null on the background. Results We identified eleven genes, Gch1, Zfp69, Dlgap1, Gna14, Yy1, Gabarapl1, Folr2, Fdft1, Cnr2, Slc24a3, and Ccl19, and a quantitative trait locus directly connected to weight, glucose, cholesterol, or free fatty acid levels in our network. None of these genes were identified by other network analyses of this mouse intercross data-set, but all have been previously associated with obesity or related pathologies in independent studies. In addition, through both simulations and data analysis we demonstrate that our algorithm achieves superior performance in terms of power and type I error control than other network recovery algorithms that use the lasso and have bounds on type I error control. Conclusions Our final network contains 118 previously associated and novel genes affecting weight, cholesterol, glucose, and free fatty acid levels that are excellent obesity risk candidates.

  3. ST-Segment Depression in Hyperventilation Indicates a False Positive Exercise Test in Patients with Mitral Valve Prolapse

    Directory of Open Access Journals (Sweden)

    Andreas P. Michaelides

    2010-01-01

    Full Text Available Objectives. Mitral valve prolapse (MVP is a known cause for false positive exercise test (ET. The purpose of this study was to establish additional electrocardiographic criteria to distinguish the false positive exercise results in patients with MVP. Methods. We studied 218 consecutive patients ( years, 103 males with MVP (according to echocardiographic study, and positive treadmill ET was performed due to multiple cardiovascular risk factors or angina-like symptoms. A coronary angiography was performed to detect coronary artery disease (CAD. Results. From 218 patients, 90 (group A presented with normal coronary arteries according to the angiography (false positive ET while the rest 128 (group B presented with CAD. ST-segment depression in hyperventilation phase was present in 54 patients of group A (60% while only in 14 patients of group B (11%, . Conclusions. Presence of ST-segment depression in hyperventilation phase favors a false positive ET in patients with MVP.

  4. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.

    2013-11-04

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.\\'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  5. On minimizing assignment errors and the trade-off between false positives and negatives in parentage analysis

    KAUST Repository

    Harrison, Hugo B.; Saenz Agudelo, Pablo; Planes, Serge; Jones, Geoffrey P.; Berumen, Michael L.

    2013-01-01

    Genetic parentage analyses provide a practical means with which to identify parent-offspring relationships in the wild. In Harrison et al.'s study (2013a), we compare three methods of parentage analysis and showed that the number and diversity of microsatellite loci were the most important factors defining the accuracy of assignments. Our simulations revealed that an exclusion-Bayes theorem method was more susceptible to false-positive and false-negative assignments than other methods tested. Here, we analyse and discuss the trade-off between type I and type II errors in parentage analyses. We show that controlling for false-positive assignments, without reporting type II errors, can be misleading. Our findings illustrate the need to estimate and report both the rate of false-positive and false-negative assignments in parentage analyses. © 2013 John Wiley & Sons Ltd.

  6. Classification of radiological errors in chest radiographs, using support vector machine on the spatial frequency features of false- negative and false-positive regions

    Science.gov (United States)

    Pietrzyk, Mariusz W.; Donovan, Tim; Brennan, Patrick C.; Dix, Alan; Manning, David J.

    2011-03-01

    Aim: To optimize automated classification of radiological errors during lung nodule detection from chest radiographs (CxR) using a support vector machine (SVM) run on the spatial frequency features extracted from the local background of selected regions. Background: The majority of the unreported pulmonary nodules are visually detected but not recognized; shown by the prolonged dwell time values at false-negative regions. Similarly, overestimated nodule locations are capturing substantial amounts of foveal attention. Spatial frequency properties of selected local backgrounds are correlated with human observer responses either in terms of accuracy in indicating abnormality position or in the precision of visual sampling the medical images. Methods: Seven radiologists participated in the eye tracking experiments conducted under conditions of pulmonary nodule detection from a set of 20 postero-anterior CxR. The most dwelled locations have been identified and subjected to spatial frequency (SF) analysis. The image-based features of selected ROI were extracted with un-decimated Wavelet Packet Transform. An analysis of variance was run to select SF features and a SVM schema was implemented to classify False-Negative and False-Positive from all ROI. Results: A relative high overall accuracy was obtained for each individually developed Wavelet-SVM algorithm, with over 90% average correct ratio for errors recognition from all prolonged dwell locations. Conclusion: The preliminary results show that combined eye-tracking and image-based features can be used for automated detection of radiological error with SVM. The work is still in progress and not all analytical procedures have been completed, which might have an effect on the specificity of the algorithm.

  7. The illusion of the positive: the impact of natural and induced mood on older adults' false recall.

    Science.gov (United States)

    Emery, Lisa; Hess, Thomas M; Elliot, Tonya

    2012-11-01

    Recent research suggests that affective and motivational processes can influence age differences in memory. In the current study, we examine the impact of both natural and induced mood state on age differences in false recall. Older and younger adults performed a version of the Deese-Roediger-McDermott (DRM; Roediger & McDermott, 1995 , Journal of Experimental Psychology: Learning, Memory, and Cognition, 21, 803) false memory paradigm in either their natural mood state or after a positive or negative mood induction. Results indicated that, after accounting for age differences in basic cognitive function, age-related differences in positive mood during the testing session were related to increased false recall in older adults. Inducing older adults into a positive mood also exacerbated age differences in false memory. In contrast, veridical recall did not appear to be systematically influenced by mood. Together, these results suggest that positive mood states can impact older adults' information processing and potentially increase underlying cognitive age differences.

  8. Early Disseminated Lyme Disease Causing False-Positive Serology for Primary Epstein-Barr Virus Infection: Report of 2 Cases.

    Science.gov (United States)

    Pavletic, Adriana J; Marques, Adriana R

    2017-07-15

    False-positive serology for Lyme disease was reported in patients with acute infectious mononucleosis. Here we describe 2 patients with early disseminated Lyme disease who were misdiagnosed with infectious mononucleosis based on false-positive tests for primary Epstein-Barr virus infection. Published by Oxford University Press for the Infectious Diseases Society of America 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  9. Data from Paper “False-Positive Psychology: Undisclosed Flexibility in Data Collection and Analysis Allows Presenting Anything as Significant”

    Directory of Open Access Journals (Sweden)

    Joseph P Simmons

    2014-02-01

    Full Text Available The data includes measures collected for the two experiments reported in “False-Positive Psychology” [1] where listening to a randomly assigned song made people feel younger (Study 1 or actually be younger (Study 2. These data are useful because they illustrate inflations of false positive rates due to flexibility in data collection, analysis, and reporting of results. Data are useful for educational purposes.

  10. Consensus-based identification of factors related to false-positives in ultrasound scanning of synovitis and tenosynovitis.

    Science.gov (United States)

    Ikeda, Kei; Narita, Akihiro; Ogasawara, Michihiro; Ohno, Shigeru; Kawahito, Yutaka; Kawakami, Atsushi; Ito, Hiromu; Matsushita, Isao; Suzuki, Takeshi; Misaki, Kenta; Ogura, Takehisa; Kamishima, Tamotsu; Seto, Yohei; Nakahara, Ryuichi; Kaneko, Atsushi; Nakamura, Takayuki; Henmi, Mihoko; Fukae, Jun; Nishida, Keiichiro; Sumida, Takayuki; Koike, Takao

    2016-01-01

    We aimed to identify causes of false-positives in ultrasound scanning of synovial/tenosynovial/bursal inflammation and provide corresponding imaging examples. We first performed systematic literature review to identify previously reported causes of false-positives. We next determined causes of false-positives and corresponding example images for educational material through Delphi exercises and discussion by 15 experts who were an instructor and/or a lecturer in the 2013 advanced course for musculoskeletal ultrasound organized by Japan College of Rheumatology Committee for the Standardization of Musculoskeletal Ultrasonography. Systematic literature review identified 11 articles relevant to sonographic false-positives of synovial/tenosynovial inflammation. Based on these studies, 21 candidate causes of false-positives were identified in the consensus meeting. Of these items, 11 achieved a predefined consensus (≥ 80%) in Delphi exercise and were classified as follows: (I) Gray-scale assessment [(A) non-specific synovial findings and (B) normal anatomical structures which can mimic synovial lesions due to either their low echogenicity or anisotropy]; (II) Doppler assessment [(A) Intra-articular normal vessels and (B) reverberation)]. Twenty-four corresponding examples with 49 still and 23 video images also achieved consensus. Our study provides a set of representative images that can help sonographers to understand false-positives in ultrasound scanning of synovitis and tenosynovitis.

  11. Immunohistochemical localization of anterior pituitary hormones in S-100 protein-positive cells in the rat pituitary gland.

    Science.gov (United States)

    Kikuchi, Motoshi; Yatabe, Megumi; Tando, Yukiko; Yashiro, Takashi

    2011-09-01

    In the anterior and intermediate lobes of the rat pituitary gland, non-hormone-producing cells that express S-100 protein coexist with various types of hormone-producing cells and are believed to function as phagocytes, supporting and paracrine-controlling cells of hormone-producing cells and stem cells, among other functions; however, their cytological characteristics are not yet fully understood. Using a transgenic rat that expresses green fluorescent protein under the promoter of the S100β protein gene, we immunohistochemically detected expression of the luteinizing hormone, thyroid-stimulating hormone, prolactin, growth hormone and proopiomelanocortin by S-100 protein-positive cells located between clusters of hormone-producing cells in the intermediate lobe. These findings lend support to the hypothesis that S-100 protein-positive cells are capable of differentiating into hormone-producing cells in the adult rat pituitary gland.

  12. Commercial radioimmunoassay for beta subunit of human chorionic gonadotropin: falsely positive determinations due to elevated serum luteinizing hormone

    International Nuclear Information System (INIS)

    Fowler, J.E. Jr.; Platoff, G.E.; Kubrock, C.A.; Stuzman, R.E.

    1982-01-01

    Among 17 men who had received seemingly curative treatment for unilateral non-seminomatous germ cell tumors for the testis and who had consistently normal serum human chorionic gonadotropin (HCG) levels at a reference laboratory, 7 (41%) had at least one falsely positive commercial serum HCG determination. To investigate the cause of these falsely positive determinations the authors measured the cross reactivity of luteinizing hormone (LH) and follicle stimulating hormone (FSH) standards in the commercial HCG assay, and studied the relationships between commercial HCG levels and serum LH levels, serum FSH levels and gonadal status in men with and without normal gonadal function. The falsely positive HCG determinations appeared to be due to elevated serum LH levels and cross reactivity of LH in the commercial HCG assay because: 1) there was substantial cross reactivity of the LH standards in the commercial assay, 2) the serum LH was elevated in four of six men with solitary testes, 3) there was a striking correlation between elevated serum LH levels and falsely elevated commercial HCG levels in ten men with solitary or absent testes, and 4) there were no falsely positive HCG determinations in 13 normal men but there were falsely positive HCG determinations in seven of ten anorchid men

  13. Interference Helps to Equalize the Read Range and Reduce False Positives of Passive RFID Tags

    DEFF Research Database (Denmark)

    Krigslund, Rasmus; Popovski, Petar; Pedersen, Gert Frølund

    2012-01-01

    In various applications of RFID systems a reader should reliably get the ID of the tags that are within a bounded proximity region, termed the interrogation zone. This gives rise to two types of errors 1) False Negative Detections (FNDs), when tags within the intended interrogation zone cannot...... interference enables design of well-defined interrogation zones for passive RFID systems....

  14. The effect of information about false negative and false positive rates on people's attitudes towards colorectal cancer screening using faecal occult blood testing (FOBt).

    Science.gov (United States)

    Miles, Anne; Rodrigues, Vania; Sevdalis, Nick

    2013-11-01

    To examine the impact of numeric risk information about false negative (FN) and false positive (FP) rates in faecal occult blood testing (FOBt) on attitudes towards screening. 95 people aged 45-59, living in England, read 6 hypothetical vignettes presented online about the use of FOB testing to detect bowel cancer, in which information about FN and FP rates was systematically varied. Both verbal and numeric FN risk information reduced people's interest in screening compared with no FN information. Numeric FN risk information reduced people's perceptions of screening effectiveness and lowered perceived trust in the results of screening compared with both verbal FN information and no FN information. FP information did not affect attitudes towards FOB testing. There was limited evidence that FN information reduced interest and perceptions of screening effectiveness more in educated groups. Numeric FN risk information decreased people's perceptions of screening effectiveness and trust in the results of screening but did not affect people's interest in screening anymore than verbal FN risk information. Numeric FN information could be added to patient information without affecting interest in screening, although this needs to be replicated in a larger, more representative sample. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  15. Effect of radiologist experience on the risk of false-positive results in breast cancer screening programs

    Energy Technology Data Exchange (ETDEWEB)

    Zubizarreta Alberdi, Raquel [Galician Breast Cancer Screening Programme, Public Health and Planning Directorate, Health Office, Galicia (Spain); Edificio Administrativo da Conselleria de Sanidade, Servicio de Programas Poboacionais de Cribado, Direccion Xeral de Saude Publica e Planificacion, Santiago de Compostela, Galicia (Spain); Llanes, Ana B.F.; Ortega, Raquel Almazan [Galician Breast Cancer Screening Programme, Public Health and Planning Directorate, Health Office, Galicia (Spain); Exposito, Ruben Roman; Collado, Jose M.V.; Oliveres, Xavier Castells [Department of Epidemiology and Evaluation, Institut Municipal d' Investigacio Medica-Parc de Salut Mar. CIBERESP, Barcelona (Spain); Queiro Verdes, Teresa [Galician Agency for Health Technology Assessment, Public Health and Planning Directorate, Health Office, Galicia (Spain); Natal Ramos, Carmen [Principality of Asturias Breast Cancer Screening Programme, Principality of Asturias (Spain); Sanz, Maria Ederra [Public Health Institute, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Salas Trejo, Dolores [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia Breast Cancer Screening Programme, Valencia (Spain)

    2011-10-15

    To evaluate the effect of radiologist experience on the risk of false-positive results in population-based breast cancer screening programmes. We evaluated 1,440,384 single-read screening mammograms, corresponding to 471,112 women aged 45-69 years participating in four Spanish programmes between 1990 and 2006. The mammograms were interpreted by 72 radiologists. The overall percentage of false-positive results was 5.85% and that for false-positives resulting in an invasive procedure was 0.38%. Both the risk of false-positives overall and of false-positives leading to an invasive procedure significantly decreased (p < 0.001) with greater reading volume in the previous year: OR 0.77 and OR 0.78, respectively, for a reading volume 500-1,999 mammograms and OR 0.59 and OR 0.60 for a reading volume of >14,999 mammograms with respect to the reference category (<500). The risk of both categories of false-positives was also significantly reduced (p < 0.001) as radiologists' years of experience increased: OR 0.96 and OR 0.84, respectively, for 1 year's experience and OR 0.72 and OR 0.73, respectively, for more than 4 years' experience with regard to the category of <1 year's experience. Radiologist experience is a determining factor in the risk of a false-positive result in breast cancer screening. (orig.)

  16. S100β-Positive Cells of Mesenchymal Origin Reside in the Anterior Lobe of the Embryonic Pituitary Gland.

    Directory of Open Access Journals (Sweden)

    Kotaro Horiguchi

    Full Text Available The anterior and intermediate lobes of the pituitary gland develop through invagination of the oral ectoderm and as they are endocrine tissues, they participate in the maintenance of vital functions via the synthesis and secretion of numerous hormones. We recently observed that several extrapituitary cells invade the anterior lobe of the developing pituitary gland. This raised the question of the origin(s of these S100β-positive cells, which are not classic endocrine cells but instead comprise a heterogeneous cell population with plural roles, especially as stem/progenitor cells. To better understand the roles of these S100β-positive cells, we performed immunohistochemical analysis using several markers in S100β/GFP-TG rats, which express GFP in S100β-expressing cells under control of the S100β promoter. GFP-positive cells were present as mesenchymal cells surrounding the developing pituitary gland and at Atwell's recess but were not present in the anterior lobe on embryonic day 15.5. These cells were negative for SOX2, a pituitary stem/progenitor marker, and PRRX1, a mesenchyme and pituitary stem/progenitor marker. However, three days later, GFP-positive and PRRX1-positive (but SOX2-negative cells were observed in the parenchyma of the anterior lobe. Furthermore, some GFP-positive cells were positive for vimentin, p75, isolectin B4, DESMIN, and Ki67. These data suggest that S100β-positive cells of extrapituitary origin invade the anterior lobe, undergoing proliferation and diverse transformation during pituitary organogenesis.

  17. S100β-Positive Cells of Mesenchymal Origin Reside in the Anterior Lobe of the Embryonic Pituitary Gland.

    Science.gov (United States)

    Horiguchi, Kotaro; Yako, Hideji; Yoshida, Saishu; Fujiwara, Ken; Tsukada, Takehiro; Kanno, Naoko; Ueharu, Hiroki; Nishihara, Hiroto; Kato, Takako; Yashiro, Takashi; Kato, Yukio

    2016-01-01

    The anterior and intermediate lobes of the pituitary gland develop through invagination of the oral ectoderm and as they are endocrine tissues, they participate in the maintenance of vital functions via the synthesis and secretion of numerous hormones. We recently observed that several extrapituitary cells invade the anterior lobe of the developing pituitary gland. This raised the question of the origin(s) of these S100β-positive cells, which are not classic endocrine cells but instead comprise a heterogeneous cell population with plural roles, especially as stem/progenitor cells. To better understand the roles of these S100β-positive cells, we performed immunohistochemical analysis using several markers in S100β/GFP-TG rats, which express GFP in S100β-expressing cells under control of the S100β promoter. GFP-positive cells were present as mesenchymal cells surrounding the developing pituitary gland and at Atwell's recess but were not present in the anterior lobe on embryonic day 15.5. These cells were negative for SOX2, a pituitary stem/progenitor marker, and PRRX1, a mesenchyme and pituitary stem/progenitor marker. However, three days later, GFP-positive and PRRX1-positive (but SOX2-negative) cells were observed in the parenchyma of the anterior lobe. Furthermore, some GFP-positive cells were positive for vimentin, p75, isolectin B4, DESMIN, and Ki67. These data suggest that S100β-positive cells of extrapituitary origin invade the anterior lobe, undergoing proliferation and diverse transformation during pituitary organogenesis.

  18. False-positive findings in Cochrane meta-analyses with and without application of trial sequential analysis

    DEFF Research Database (Denmark)

    Imberger, Georgina; Thorlund, Kristian; Gluud, Christian

    2016-01-01

    outcome, a negative result and sufficient power. We defined a negative result as one where the 95% CI for the effect included 1.00, a positive result as one where the 95% CI did not include 1.00, and sufficient power as the required information size for 80% power, 5% type 1 error, relative risk reduction...... of 10% or number needed to treat of 100, and control event proportion and heterogeneity taken from the included studies. We re-conducted the meta-analyses, using conventional cumulative techniques, to measure how many false positives would have occurred if these meta-analyses had been updated after each...... new trial. For each false positive, we performed TSA, using three different approaches. RESULTS: We screened 4736 systematic reviews to find 100 meta-analyses that fulfilled our inclusion criteria. Using conventional cumulative meta-analysis, false positives were present in seven of the meta...

  19. [False positive serum des-gamma-carboxy prothrombin after resection of hepatocellular carcinoma].

    Science.gov (United States)

    Hiramatsu, Kumiko; Tanaka, Yasuhito; Takagi, Kazumi; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2007-04-01

    Measurements of serum concentrations of des-gamma-carboxy-prothrombin (PIVKA-II) are widely used for diagnosing hepatocellular carcinoma (HCC). Recently, when we evaluated the correlation of PIVKA-II between two commercially available PIVKA-II immunoassay kits (Lumipulse f vs. Picolumi) to introduce it in our hospital, false high values of PIVKA-II were observed in Lumipulse assay. Four(4%) of 100 serum samples showed false high values, and all of them were obtained from patients less than 2 month after curative resection of HCC. Examining additional 7 patients with HCC resection, serum samples from the 5 patients had the same trend. To elucidate the non-specific reaction by Lumipulse assay which utilized alkaline phosphatase (ALP) enzymatic reaction, inhibition assays by various absorbents such as inactive ALP and IgM antibodies were performed. Excess of inactive ALP reduced the high values of PIVKA-II. Note that anti-bleeding sheets (fibrinogen combined drug), which included bovine thrombin, were directly attached on liver of all patients with HCC resection in this study. As the sheets also contaminate ALP and probably produce IgM antibodies to ALP, the IgM may cross-react with anti-PIVKA-II antibodies directly. Taken together, it was suggested that produced antibodies against ALP derived from anti-bleeding sheets led false high values of PIVKA-II in the patients with HCC resection.

  20. Prospective assessment of the false positive rate of the Australian snake venom detection kit in healthy human samples.

    Science.gov (United States)

    Nimorakiotakis, Vasilios Bill; Winkel, Kenneth D

    2016-03-01

    The Snake Venom Detection Kit (SVDK; bioCSL Pty Ltd, Australia) distinguishes venom from the five most medically significant snake immunotypes found in Australia. This study assesses the rate of false positives that, by definition, refers to a positive assay finding in a sample from someone who has not been bitten by a venomous snake. Control unbroken skin swabs, simulated bite swabs and urine specimens were collected from 61 healthy adult volunteers [33 males and 28 females] for assessment. In all controls, simulated bite site and urine samples [a total of 183 tests], the positive control well reacted strongly within one minute and no test wells reacted during the ten minute incubation period. However, in two urine tests, the negative control well gave a positive reaction (indicating an uninterpretable test). A 95% confidence interval for the false positive rate, on a per-patient rate, derived from the findings of this study, would extend from 0% to 6% and, on a per-test basis, it would be 0-2%. It appears to be a very low incidence (0-6%) of intrinsic true false positives for the SVDK. The clinical impresssion of a high SVDK false positive rate may be mostly related to operator error. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  1. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    -ups at 2 and 12 months postscreening. At 2 months, there was a moderate multivariate effect of group on distress; and intrusive thinking and worry about breast cancer, in particular, were most frequent amongst the false positives. Intrusive thinking still prevailed at 12 months, in addition to a higher...... findings (n=1407), false-positive findings (n=492) and referents from outside the screening programme (n=1718, age 48-49 years). Distress was measured as illness worry, anxiety, depression, cancer beliefs and early detection behaviour. Measurements were one month before screening invitation with follow...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  2. A false-positive detection bias as a function of state and trait schizotypy in interaction with intelligence

    Directory of Open Access Journals (Sweden)

    Phillip eGrant

    2014-09-01

    Full Text Available Hallucinatory experiences are by far not limited to patients with clinical psychosis. A number of internal and external factors may bring about such experiences in healthy individuals, whereby the personality trait of (positive schizotypy is a major mediator of individual differences. Psychotic experiences are defined as associating abnormal meaning to real but objectively irrelevant perceptions. Especially the ambiguity of a stimulus correlates positively with the likelihood of abnormal interpretation, and intelligence is believed to have an important influence and act as protective against clinical psychosis in highly schizotypic individuals.In this study we presented 131 healthy participants with 216 15-letter strings containing either a word, a non-word or only random letters and asked them to report, whether or not they believed to have seen a word. The aim was to replicate findings that participants with high values in positive schizotypy on the trait-level make more false-positive errors and assess the role of stimulus-ambiguity and verbal intelligence. Additionally, we wanted to examine whether the same effect could be shown for indices of state schizotypy.Our results support findings that both state and trait positive schizotypy explain significant variance in seeing things that are not there and that the properties of individual stimuli have additional strong effects on the false-positive hit rates. Finally, we found that verbal intelligence and positive schizotypy interact with stimulus-ambiguity in the production of false-positive perceptions.

  3. A false-positive detection bias as a function of state and trait schizotypy in interaction with intelligence.

    Science.gov (United States)

    Grant, Phillip; Balser, Mona; Munk, Aisha Judith Leila; Linder, Jens; Hennig, Juergen

    2014-01-01

    Hallucinatory experiences are by far not limited to patients with clinical psychosis. A number of internal and external factors may bring about such experiences in healthy individuals, whereby the personality trait of (positive) schizotypy is a major mediator of individual differences. Psychotic experiences are defined as associating abnormal meaning to real but objectively irrelevant perceptions. Especially, the ambiguity of a stimulus correlates positively with the likelihood of abnormal interpretation, and intelligence is believed to have an important influence and act as protective against clinical psychosis in highly schizotypic individuals. In this study, we presented 131 healthy participants with 216 15-letter strings containing either a word, a non-word, or only random letters and asked them to report, whether or not they believed to have seen a word. The aim was to replicate findings that participants with high values in positive schizotypy on the trait-level make more false-positive errors and assess the role of stimulus-ambiguity and verbal intelligence. Additionally, we wanted to examine whether the same effect could be shown for indices of state schizotypy. Our results support findings that both state and trait positive schizotypy explain significant variance in "seeing things that are not there" and that the properties of individual stimuli have additional strong effects on the false-positive hit rates. Finally, we found that verbal intelligence and positive schizotypy interact with stimulus-ambiguity in the production of false-positive perceptions.

  4. The probability of false positives in zero-dimensional analyses of one-dimensional kinematic, force and EMG trajectories.

    Science.gov (United States)

    Pataky, Todd C; Vanrenterghem, Jos; Robinson, Mark A

    2016-06-14

    A false positive is the mistake of inferring an effect when none exists, and although α controls the false positive (Type I error) rate in classical hypothesis testing, a given α value is accurate only if the underlying model of randomness appropriately reflects experimentally observed variance. Hypotheses pertaining to one-dimensional (1D) (e.g. time-varying) biomechanical trajectories are most often tested using a traditional zero-dimensional (0D) Gaussian model of randomness, but variance in these datasets is clearly 1D. The purpose of this study was to determine the likelihood that analyzing smooth 1D data with a 0D model of variance will produce false positives. We first used random field theory (RFT) to predict the probability of false positives in 0D analyses. We then validated RFT predictions via numerical simulations of smooth Gaussian 1D trajectories. Results showed that, across a range of public kinematic, force/moment and EMG datasets, the median false positive rate was 0.382 and not the assumed α=0.05, even for a simple two-sample t test involving N=10 trajectories per group. The median false positive rate for experiments involving three-component vector trajectories was p=0.764. This rate increased to p=0.945 for two three-component vector trajectories, and to p=0.999 for six three-component vectors. This implies that experiments involving vector trajectories have a high probability of yielding 0D statistical significance when there is, in fact, no 1D effect. Either (a) explicit a priori identification of 0D variables or (b) adoption of 1D methods can more tightly control α. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Way forward in case of a false positive in vitro genotoxicity result for a cosmetic substance?

    Science.gov (United States)

    Doktorova, Tatyana Y; Ates, Gamze; Vinken, Mathieu; Vanhaecke, Tamara; Rogiers, Vera

    2014-02-01

    The currently used regulatory in vitro mutagenicity/genotoxicity test battery has a high sensitivity for detecting genotoxicants, but it suffers from a large number of irrelevant positive results (i.e. low specificity) thereby imposing the need for additional follow-up by in vitro and/or in vivo genotoxicity tests. This could have a major impact on the cosmetic industry in Europe, seen the imposed animal testing and marketing bans on cosmetics and their ingredients. Afflicted, but safe substances could therefore be lost. Using the example of triclosan, a cosmetic preservative, we describe here the potential applicability of a human toxicogenomics-based in vitro assay as a potential mechanistically based follow-up test for positive in vitro genotoxicity results. Triclosan shows a positive in vitro chromosomal aberration test, but is negative during in vivo follow-up tests. Toxicogenomics analysis unequivocally shows that triclosan is identified as a compound acting through non-DNA reactive mechanisms. This proof-of-principle study illustrates the potential of genome-wide transcriptomics data in combination with in vitro experimentation as a possible weight-of-evidence follow-up approach for de-risking a positive outcome in a standard mutagenicity/genotoxicity battery. As such a substantial number of cosmetic compounds wrongly identified as genotoxicants could be saved for the future. Copyright © 2013 Elsevier Ltd. All rights reserved.

  6. False-Positive Rate of AKI Using Consensus Creatinine–Based Criteria

    Science.gov (United States)

    Lin, Jennie; Fernandez, Hilda; Shashaty, Michael G.S.; Negoianu, Dan; Testani, Jeffrey M.; Berns, Jeffrey S.; Parikh, Chirag R.

    2015-01-01

    Background and objectives Use of small changes in serum creatinine to diagnose AKI allows for earlier detection but may increase diagnostic false–positive rates because of inherent laboratory and biologic variabilities of creatinine. Design, setting, participants, & measurements We examined serum creatinine measurement characteristics in a prospective observational clinical reference cohort of 2267 adult patients with AKI by Kidney Disease Improving Global Outcomes creatinine criteria and used these data to create a simulation cohort to model AKI false–positive rates. We simulated up to seven successive blood draws on an equal population of hypothetical patients with unchanging true serum creatinine values. Error terms generated from laboratory and biologic variabilities were added to each simulated patient’s true serum creatinine value to obtain the simulated measured serum creatinine for each blood draw. We determined the proportion of patients who would be erroneously diagnosed with AKI by Kidney Disease Improving Global Outcomes creatinine criteria. Results Within the clinical cohort, 75.0% of patients received four serum creatinine draws within at least one 48-hour period during hospitalization. After four simulated creatinine measurements that accounted for laboratory variability calculated from assay characteristics and 4.4% of biologic variability determined from the clinical cohort and publicly available data, the overall false–positive rate for AKI diagnosis was 8.0% (interquartile range =7.9%–8.1%), whereas patients with true serum creatinine ≥1.5 mg/dl (representing 21% of the clinical cohort) had a false–positive AKI diagnosis rate of 30.5% (interquartile range =30.1%–30.9%) versus 2.0% (interquartile range =1.9%–2.1%) in patients with true serum creatinine values false–positive rates caused by inherent variability of serum creatinine at higher baseline values, potentially misclassifying patients with CKD in AKI studies. PMID

  7. False Advertising

    OpenAIRE

    Rhodes, Andrew; Wilson, Chris M

    2016-01-01

    There is widespread evidence that some firms use false advertising to overstate the value of their products. We consider a model in which a policymaker is able to punish such false claims. We characterize an equilibrium where false advertising actively influences rational buyers, and analyze the effects of policy under different welfare objectives. We establish precise conditions where policy optimally permits a positive level of false advertising, and show how these conditions vary intuitive...

  8. Internal Impingement of the Shoulder: A Risk of False Positive Test Outcomes in External Impingement Tests?

    Directory of Open Access Journals (Sweden)

    Tim Leschinger

    2017-01-01

    Full Text Available Background. External impingement tests are considered as being particularly reliable for identifying subacromial and coracoid shoulder impingement mechanisms. The purpose of the present study was to evaluate if these tests are likely to provoke an internal shoulder impingement mechanism which, in cases of a pathologic condition, can lead to a positive test result. Method. In 37 subjects, the mechanical contact between the glenoid rim and the rotator cuff (RC was measured quantitatively and qualitatively in external impingement test positions using an open MRI system. Results. Mechanical contact of the supraspinatus with the posterosuperior glenoid was present in 30 subjects in the Neer test. In the Hawkins test, the subscapularis was in contact with the anterosuperior glenoid in 33 subjects and the supraspinatus in 18. In the horizontal impingement test, anterosuperior contact of the supraspinatus with the glenoid was identified in 35 subjects. Conclusion. The Neer, Hawkins, and horizontal impingement tests are likely to provoke the mechanism of an internal shoulder impingement. A posterosuperior internal impingement mechanism is being provoked predominately in the Neer test. The Hawkins test narrows the distance between the insertions of the subscapularis and supraspinatus and the anterosuperior labrum, which leads to an anterosuperior impingement mechanism.

  9. False-Positive Rate Determination of Protein Target Discovery using a Covalent Modification- and Mass Spectrometry-Based Proteomics Platform

    Science.gov (United States)

    Strickland, Erin C.; Geer, M. Ariel; Hong, Jiyong; Fitzgerald, Michael C.

    2014-01-01

    Detection and quantitation of protein-ligand binding interactions is important in many areas of biological research. Stability of proteins from rates of oxidation (SPROX) is an energetics-based technique for identifying the proteins targets of ligands in complex biological mixtures. Knowing the false-positive rate of protein target discovery in proteome-wide SPROX experiments is important for the correct interpretation of results. Reported here are the results of a control SPROX experiment in which chemical denaturation data is obtained on the proteins in two samples that originated from the same yeast lysate, as would be done in a typical SPROX experiment except that one sample would be spiked with the test ligand. False-positive rates of 1.2-2.2 % and analysis of the isobaric mass tag (e.g., iTRAQ®) reporter ions used for peptide quantitation. Our results also suggest that technical replicates can be used to effectively eliminate such false positives that result from this random error, as is demonstrated in a SPROX experiment to identify yeast protein targets of the drug, manassantin A. The impact of ion purity in the tandem mass spectral analyses and of background oxidation on the false-positive rate of protein target discovery using SPROX is also discussed.

  10. False-positive cryptococcal antigen test associated with use of BBL Port-a-Cul transport vials.

    Science.gov (United States)

    Wilson, Deborah A; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S; Procop, Gary W

    2011-02-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed.

  11. False-Positive Cryptococcal Antigen Test Associated with Use of BBL Port-A-Cul Transport Vials▿

    Science.gov (United States)

    Wilson, Deborah A.; Sholtis, Mary; Parshall, Sharon; Hall, Gerri S.; Procop, Gary W.

    2011-01-01

    A total of 52 residual CSF and serum specimens, which were originally negative with the Cryptococcal Antigen Latex Agglutination System (CALAS), were shown to become falsely positive after placement in BBL Port-A-Cul anaerobic transport vials. This transport device, although excellent for specimen transportation for subsequent culture, should not be used if cryptococcal antigen testing is needed. PMID:21159939

  12. Reduction of false positives in the detection of architectural distortion in mammograms by using a geometrically constrained phase portrait model

    International Nuclear Information System (INIS)

    Ayres, Fabio J.; Rangayyan, Rangaraj M.

    2007-01-01

    Objective One of the commonly missed signs of breast cancer is architectural distortion. We have developed techniques for the detection of architectural distortion in mammograms, based on the analysis of oriented texture through the application of Gabor filters and a linear phase portrait model. In this paper, we propose constraining the shape of the general phase portrait model as a means to reduce the false-positive rate in the detection of architectural distortion. Material and methods The methods were tested with one set of 19 cases of architectural distortion and 41 normal mammograms, and with another set of 37 cases of architectural distortion. Results Sensitivity rates of 84% with 4.5 false positives per image and 81% with 10 false positives per image were obtained for the two sets of images. Conclusion The adoption of a constrained phase portrait model with a symmetric matrix and the incorporation of its condition number in the analysis resulted in a reduction in the false-positive rate in the detection of architectural distortion. The proposed techniques, dedicated for the detection and localization of architectural distortion, should lead to efficient detection of early signs of breast cancer. (orig.)

  13. A False Positive I-131 Metastatic Survey Caused by Radioactive Iodine Uptake by a Benign Thymic Cyst

    Directory of Open Access Journals (Sweden)

    Avneet K. Singh

    2017-01-01

    Full Text Available Thyroid carcinoma is the most common endocrine malignancy in the United States with increasing incidence and diagnosis but stable mortality. Differentiated thyroid cancer rarely presents with distant metastases and is associated with a low risk of morbidity and mortality. Despite this, current protocols recommend remnant ablation with radioactive iodine and evaluation for local and distant metastasis in some patients with higher risk disease. There are several case reports of false positive results of metastatic surveys that are either normal physiologic variants or other pathological findings. Most false positive findings are associated with tissue that has physiologic increased uptake of I-131, such as breast tissue or lung tissue; pathological findings such as thymic cysts are also known to have increased uptake. Our case describes a rare finding of a thymic cyst found on a false positive I-131 metastatic survey. The patient was taken for surgical excision and the final pathology was a benign thymic cyst. Given that pulmonary metastases of differentiated thyroid cancer are rare, thymic cysts, though also rare, must be part of the differential diagnosis for false positive findings on an I-131 survey.

  14. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    Energy Technology Data Exchange (ETDEWEB)

    Roman, M., E-mail: Marta.Roman@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Department of Women and Children’s Health, Oslo University Hospital, Oslo (Norway); Skaane, P., E-mail: PERSK@ous-hf.no [Department of Radiology, Oslo University Hospital Ullevaal, University of Oslo, Oslo (Norway); Hofvind, S., E-mail: Solveig.Hofvind@kreftregisteret.no [Cancer Registry of Norway, Oslo (Norway); Oslo and Akershus University College of Applied Sciences, Faculty of Health Science, Oslo (Norway)

    2014-09-15

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  15. The cumulative risk of false-positive screening results across screening centres in the Norwegian Breast Cancer Screening Program

    International Nuclear Information System (INIS)

    Roman, M.; Skaane, P.; Hofvind, S.

    2014-01-01

    Highlights: • We found variation in early performance measures across screening centres. • Radiologists’ performance may play a key role in the variability. • Potential to improve the effectiveness of breast cancer screening programs. • Continuous surveillance of screening centres and radiologists is essential. - Abstract: Background: Recall for assessment in mammographic screening entails an inevitable number of false-positive screening results. This study aimed to investigate the variation in the cumulative risk of a false positive screening result and the positive predictive value across the screening centres in the Norwegian Breast Cancer Screening Program. Methods: We studied 618,636 women aged 50–69 years who underwent 2,090,575 screening exams (1996–2010. Recall rate, positive predictive value, rate of screen-detected cancer, and the cumulative risk of a false positive screening result, without and with invasive procedures across the screening centres were calculated. Generalized linear models were used to estimate the probability of a false positive screening result and to compute the cumulative false-positive risk for up to ten biennial screening examinations. Results: The cumulative risk of a false-positive screening exam varied from 10.7% (95% CI: 9.4–12.0%) to 41.5% (95% CI: 34.1–48.9%) across screening centres, with a highest to lowest ratio of 3.9 (95% CI: 3.7–4.0). The highest to lowest ratio for the cumulative risk of undergoing an invasive procedure with a benign outcome was 4.3 (95% CI: 4.0–4.6). The positive predictive value of recall varied between 12.0% (95% CI: 11.0–12.9%) and 19.9% (95% CI: 18.3–21.5%), with a highest to lowest ratio of 1.7 (95% CI: 1.5–1.9). Conclusions: A substantial variation in the performance measures across the screening centres in the Norwegian Breast Cancer Screening Program was identified, despite of similar administration, procedures, and quality assurance requirements. Differences in the

  16. Evaluation of Patients with an Apparent False Positive Stool DNA Test: The Role of Repeat Stool DNA Testing.

    Science.gov (United States)

    Cooper, Gregory S; Markowitz, Sanford D; Chen, Zhengyi; Tuck, Missy; Willis, Joseph E; Berger, Barry M; Brenner, Dean E; Li, Li

    2018-03-07

    There is uncertainty as to the appropriate follow-up of patients who test positive on multimarker stool DNA (sDNA) testing and have a colonoscopy without neoplasia. To determine the prevalence of missed colonic or occult upper gastrointestinal neoplasia in patients with an apparent false positive sDNA. We prospectively identified 30 patients who tested positive with a commercially available sDNA followed by colonoscopy without neoplastic lesions. Patients were invited to undergo repeat sDNA at 11-29 months after the initial test followed by repeat colonoscopy and upper endoscopy. We determined the presence of neoplastic lesions on repeat evaluation stratified by results of repeat sDNA. Twelve patients were restudied. Seven patients had a negative second sDNA test and a normal second colonoscopy and upper endoscopy. In contrast, 5 of 12 subjects had a persistently positive second sDNA test, and 3 had positive findings, including a 3-cm sessile transverse colon adenoma with high-grade dysplasia, a 2-cm right colon sessile serrated adenoma with dysplasia, and a nonadvanced colon adenoma (p = 0.045). These corresponded to a positive predictive value of 0.60 (95% CI 0.17-1.00) and a negative predictive value of 1.00 (95% CI 1.00-1.00) for the second sDNA test. In addition, the medical records of all 30 subjects with apparent false positive testing were reviewed and no documented cases of malignant tumors were recorded. Repeat positive sDNA testing may identify a subset of patients with missed or occult colorectal neoplasia after negative colonoscopy for an initially positive sDNA. High-quality colonoscopy with careful attention to the right colon in patients with positive sDNA is critically important and may avoid false negative colonoscopy.

  17. Case of false positive scanning observed after radiation therapy for orbital tumor

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, H [Gifu Prefectural Tajimi Hospital (Japan); Nakamura, K; Maeda, S; Watanabe, R; Miyajima, T

    1978-12-01

    A report was made of 56-year-old female patient of abducensparesis. In the early stage the cause remained undetermined with nothing abnormal noted in scintigraphy. Diplopia disappeared once, but right, exophalmus relapsed. In gammaencepharography, a hot spot was noted in the orbita, sinus ethmoidalis and sirus sphenoidalis. In an operation, squamous cell carcinoma was removed and radiation therapy was performed (total dose of 3520 r) and, three months later a scintigraphy disclosed a high spot of /sup 203/Hg uptake ratio in the right orbita and its lower portions. The biopsy of these portions disclosed a necrotic tissue instead of a tumor. In scintigraphy after radiation therapy against the tumor, it was reported that a positive scintigraphy was present because of the vascular trouble of said portions, although the tumor had disappeared. Attention should be given as well as an opinion of high density together with the examination by CT, especially as to enhancement.

  18. A Case of False-Positive Mycobacterium tuberculosis Caused by Mycobacterium celatum

    Directory of Open Access Journals (Sweden)

    Edward Gildeh

    2016-01-01

    Full Text Available Mycobacterium celatum is a nontuberculous mycobacterium shown to cause symptoms similar to pulmonary M. tuberculosis. Certain strains have been shown to cross-react with the probes used to detect M. tuberculosis, making this a diagnostic challenge. We present a 56-year-old gentleman who developed signs and symptoms of lung infection with computed tomography scan of the chest showing right lung apex cavitation. Serial sputum samples were positive for acid-fast bacilli and nucleic acid amplification testing identified M. tuberculosis ribosomal RNA, resulting in treatment initiation. Further testing with high performance liquid chromatography showed a pattern consistent with M. celatum. This case illustrates the potential for M. celatum to mimic M. tuberculosis in both its clinical history and laboratory testing due to the identical oligonucleotide sequence contained in both. An increasing number of case reports suggest that early reliable differentiation could reduce unnecessary treatment and public health intervention associated with misdiagnosed tuberculosis.

  19. Distinguishing Binders from False Positives by Free Energy Calculations: Fragment Screening Against the Flap Site of HIV Protease

    Science.gov (United States)

    2015-01-01

    Molecular docking is a powerful tool used in drug discovery and structural biology for predicting the structures of ligand–receptor complexes. However, the accuracy of docking calculations can be limited by factors such as the neglect of protein reorganization in the scoring function; as a result, ligand screening can produce a high rate of false positive hits. Although absolute binding free energy methods still have difficulty in accurately rank-ordering binders, we believe that they can be fruitfully employed to distinguish binders from nonbinders and reduce the false positive rate. Here we study a set of ligands that dock favorably to a newly discovered, potentially allosteric site on the flap of HIV-1 protease. Fragment binding to this site stabilizes a closed form of protease, which could be exploited for the design of allosteric inhibitors. Twenty-three top-ranked protein–ligand complexes from AutoDock were subject to the free energy screening using two methods, the recently developed binding energy analysis method (BEDAM) and the standard double decoupling method (DDM). Free energy calculations correctly identified most of the false positives (≥83%) and recovered all the confirmed binders. The results show a gap averaging ≥3.7 kcal/mol, separating the binders and the false positives. We present a formula that decomposes the binding free energy into contributions from the receptor conformational macrostates, which provides insights into the roles of different binding modes. Our binding free energy component analysis further suggests that improving the treatment for the desolvation penalty associated with the unfulfilled polar groups could reduce the rate of false positive hits in docking. The current study demonstrates that the combination of docking with free energy methods can be very useful for more accurate ligand screening against valuable drug targets. PMID:25189630

  20. False-positive pregnancy test after transfusion of solvent/detergent-treated plasma.

    Science.gov (United States)

    Jilma-Stohlawetz, Petra; Wreford-Bush, Tim; Mills, Francesca; Davidson, Fiona; Kursten, Friedrich W; Jilma, Bernd; Birchall, Janet

    2017-12-01

    The transmission of pathogens, antibodies, and proteins is a possible consequence of blood product transfusion. A female patient had an unexpected positive serum β-human chorionic gonadotropin result, indicative of pregnancy, after she had received a transfusion with 1 unit of platelet concentrate, 4 units of red blood cells, and 4 units of pooled solvent/detergent-treated plasma (Octaplas). To investigate the possibility of passive transfusion of β-human chorionic gonadotropin from the plasma transfusion, one additional unit from the same batch was thawed and analyzed. To validate the β-human chorionic gonadotropin assay for use in solvent/detergent-treated plasma and to investigate any interference in the assay, dilution experiments were performed using the implicated plasma batch diluted with male and non-pregnant female sera. Also, plasma from a known pregnant woman was diluted with Octaplas (tested negative for β-human chorionic gonadotropin) and with a male serum to validate the assay for use in solvent/detergent-treated plasma. The implicated solvent/detergent-treated plasma had a mean β-human chorionic gonadotropin level of 91.5 mIU/mL. Results from the dilution experiments revealed an excellent correlation (r > 0.99) between β-human chorionic gonadotropin measurement in solvent/detergent-treated plasma and male serum and no over or under recovery of the expected results. Further measurements of β-human chorionic gonadotropin levels in the female recipient revealed an estimated half-life of 6 hours. This case demonstrates the importance of considering the possibility of passive transmission of analytes to a patient from the transfusion of blood products. Furthermore, the measurement of β-human chorionic gonadotropin is valid in solvent/detergent-treated plasma using a Roche Cobas analyzer. © 2017 AABB.

  1. Predicting residue contacts using pragmatic correlated mutations method: reducing the false positives

    Directory of Open Access Journals (Sweden)

    Alexov Emil G

    2006-11-01

    Full Text Available Abstract Background Predicting residues' contacts using primary amino acid sequence alone is an important task that can guide 3D structure modeling and can verify the quality of the predicted 3D structures. The correlated mutations (CM method serves as the most promising approach and it has been used to predict amino acids pairs that are distant in the primary sequence but form contacts in the native 3D structure of homologous proteins. Results Here we report a new implementation of the CM method with an added set of selection rules (filters. The parameters of the algorithm were optimized against fifteen high resolution crystal structures with optimization criterion that maximized the confidentiality of the predictions. The optimization resulted in a true positive ratio (TPR of 0.08 for the CM without filters and a TPR of 0.14 for the CM with filters. The protocol was further benchmarked against 65 high resolution structures that were not included in the optimization test. The benchmarking resulted in a TPR of 0.07 for the CM without filters and to a TPR of 0.09 for the CM with filters. Conclusion Thus, the inclusion of selection rules resulted to an overall improvement of 30%. In addition, the pair-wise comparison of TPR for each protein without and with filters resulted in an average improvement of 1.7. The methodology was implemented into a web server http://www.ces.clemson.edu/compbio/recon that is freely available to the public. The purpose of this implementation is to provide the 3D structure predictors with a tool that can help with ranking alternative models by satisfying the largest number of predicted contacts, as well as it can provide a confidence score for contacts in cases where structure is known.

  2. Restricted Boltzmann machines based oversampling and semi-supervised learning for false positive reduction in breast CAD.

    Science.gov (United States)

    Cao, Peng; Liu, Xiaoli; Bao, Hang; Yang, Jinzhu; Zhao, Dazhe

    2015-01-01

    The false-positive reduction (FPR) is a crucial step in the computer aided detection system for the breast. The issues of imbalanced data distribution and the limitation of labeled samples complicate the classification procedure. To overcome these challenges, we propose oversampling and semi-supervised learning methods based on the restricted Boltzmann machines (RBMs) to solve the classification of imbalanced data with a few labeled samples. To evaluate the proposed method, we conducted a comprehensive performance study and compared its results with the commonly used techniques. Experiments on benchmark dataset of DDSM demonstrate the effectiveness of the RBMs based oversampling and semi-supervised learning method in terms of geometric mean (G-mean) for false positive reduction in Breast CAD.

  3. Usefulness of exercise ECG test with nitroglycerin and exercise cardiac scintigraphy in patients with false positive exercise ECG test

    International Nuclear Information System (INIS)

    Moritani, Kohshiro

    1984-01-01

    The purpose of this study is to evaluate the clinical usefulness of exercise (Ex) ECG test with sublingual nitroglycerin (NTG) and Ex cardiac scintigraphy in differentiating false positive responses from true positive responses of Ex ECG test. We examined 7 pts (age : 46+-7 years) with true positive Ex ECG test (TP) and 8 pts (age : 55+-10 years) with false positive Ex ECG test (FP). TP had significant coronary artery disease and FP did not. Ex test was done by multistage ergometer test. In 5 pts of TP and all pts of FP, Ex cardiac scintigraphy was performed. In TP, Ex cardiac scintigraphy revealed reversible perfusion deficit, but not in FP. NTG was administered 3 minutes before Ex test was started. Ex test with NTG was terminated at the same load as Ex test without NTG. Pressure-rate products at the end point of Ex test did not show significant difference between Ex test without NTG and that with NTG (TP: 203x10 2 , 213x10 2 , FP: 196x10 2 , 206x10 2 , respectively). In 7 pts of FP, ST depression in Ex test without NTG was not improved in Ex test with NTG. On the other hand, in all pts of TP, ST depression seen in Ex test without NTG, was not observed in Ex test with NTG. It may be concluded that Ex cardiac scintigraphy is diagnostic for differentiation of false positive responses from true positive responses of Ex ECG test, as well as Ex ECG test with NTG is. (author)

  4. Decisions to shoot in a weapon identification task: The influence of cultural stereotypes and perceived threat on false positive errors.

    Science.gov (United States)

    Fleming, Kevin K; Bandy, Carole L; Kimble, Matthew O

    2010-01-01

    The decision to shoot a gun engages executive control processes that can be biased by cultural stereotypes and perceived threat. The neural locus of the decision to shoot is likely to be found in the anterior cingulate cortex (ACC), where cognition and affect converge. Male military cadets at Norwich University (N=37) performed a weapon identification task in which they made rapid decisions to shoot when images of guns appeared briefly on a computer screen. Reaction times, error rates, and electroencephalogram (EEG) activity were recorded. Cadets reacted more quickly and accurately when guns were primed by images of Middle-Eastern males wearing traditional clothing. However, cadets also made more false positive errors when tools were primed by these images. Error-related negativity (ERN) was measured for each response. Deeper ERNs were found in the medial-frontal cortex following false positive responses. Cadets who made fewer errors also produced deeper ERNs, indicating stronger executive control. Pupil size was used to measure autonomic arousal related to perceived threat. Images of Middle-Eastern males in traditional clothing produced larger pupil sizes. An image of Osama bin Laden induced the largest pupil size, as would be predicted for the exemplar of Middle East terrorism. Cadets who showed greater increases in pupil size also made more false positive errors. Regression analyses were performed to evaluate predictions based on current models of perceived threat, stereotype activation, and cognitive control. Measures of pupil size (perceived threat) and ERN (cognitive control) explained significant proportions of the variance in false positive errors to Middle-Eastern males in traditional clothing, while measures of reaction time, signal detection response bias, and stimulus discriminability explained most of the remaining variance.

  5. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    The aim of this study was to examine psychological distress in a mammography screening process as a consequence of screening after adjusting for background, personality and prescreening distress. Subjects, aged 50 years, were invitees at their first screening. There were three groups; normal find...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  6. False positive results occurring in a radioimmunoassay for hepatitis A IgM antibody of the IgM class

    Energy Technology Data Exchange (ETDEWEB)

    Bucens, M R; Pietroboni, G R; Harnett, G B [Virus Lab., Combined Microbiology Service, Queen Elizabeth II Medical Centre, Perth, Western Australia

    1983-12-01

    The diagnosis of hepatitis A infection is usually based on the presence of hepatitis A specific IgM in a single serum sample. The fortuitous observation in one patient that this reactivity was apparently still present 19 mth after her original illness led to the discovery that the ABBOTT HAVAB-M kit method may produce false positive results. A series of patients who had previously had hepatitis A was retested and false positive results were found in 6% of this group. Control groups consisted of patients with other acute and chronic liver disorders and other acute viral diseases. No reactivity was detected in the control sera. Sucrose gradient fractionation revealed that the factor responsible for the false positive results was associated only with serum fractions containing IgA and IgG and that it could be removed by absorption of sera with staphylococcal protein A but not by absorption with streptococcus AR1 or by 2-mercaptoethanol treatment. It was concluded that following hepatitis A infection some patients produce a rheumatoid factor-like substance (not of IgM class) which is cleared from the serum in 2-3 yr. The presence of this factor may lead to a misdiagnosis in patients presenting with jaundice.

  7. One Hundred False-Positive Amphetamine Specimens Characterized by Liquid Chromatography Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Marin, Stephanie J; Doyle, Kelly; Chang, Annie; Concheiro-Guisan, Marta; Huestis, Marilyn A; Johnson-Davis, Kamisha L

    2016-01-01

    Some amphetamine (AMP) and ecstacy (MDMA) urine immunoassay (IA) kits are prone to false-positive results due to poor specificity of the antibody. We employed two techniques, high-resolution mass spectrometry (HRMS) and an in silico structure search, to identify compounds likely to cause false-positive results. Hundred false-positive IA specimens for AMP and/or MDMA were analyzed by an Agilent 6230 time-of-flight (TOF) mass spectrometer. Separately, SciFinder (Chemical Abstracts) was used as an in silico structure search to generate a library of compounds that are known to cross-react with AMP/MDMA IAs. Chemical formulas and exact masses of 145 structures were then compared against masses identified by TOF. Compounds known to have cross-reactivity with the IAs were identified in the structure-based search. The chemical formulas and exact masses of 145 structures (of 20 chemical formulas) were compared against masses identified by TOF. Urine analysis by HRMS correlates accurate mass with chemical formulae, but provides little information regarding compound structure. Structural data of targeted antigens can be utilized to correlate HRMS-derived chemical formulas with structural analogs. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Occurrence of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae isolates.

    Directory of Open Access Journals (Sweden)

    Peng Wang

    Full Text Available Adequate detection of the production of carbapenemase in Enterobacteriaceae isolates is crucial for infection control measures and the appropriate choice of antimicrobial therapy. In this study, we investigated the frequency of false positive results for the detection of carbapenemases in carbapenemase-negative Escherichia coli and Klebsiella pneumoniae clinical isolates by the modified Hodge test (MHT. Three hundred and one E. coli and K. pneumoniae clinical isolates were investigated. All produced extended spectrum β-lactamases (ESBLs but were susceptible to carbapenems. Antimicrobial susceptibility testing was performed by the disk diffusion and agar dilution methods. The MHT was performed using the standard inoculum of test organisms recommended by the CLSI. Genes that encoded ESBLs and carbapenemases were identified by PCR and DNA sequencing. Among the 301 clinical isolates, none of the isolates conformed to the criteria for carbapenemase screening recommended by the CLSI. The susceptibility rates for imipenem, meropenem, and ertapenem all were 100.0%, 100.0%, and 100.0%, respectively. Of the 301 E. coli and K. pneumoniae isolates, none produced carbapenemase. The MHT gave a positive result for 3.3% (10/301 of the isolates. False positive results can occur when the MHT is used to detect carbapenemase in ESBL-producing isolates and clinical laboratories must be aware of this fact.

  9. Multi-scale textural feature extraction and particle swarm optimization based model selection for false positive reduction in mammography.

    Science.gov (United States)

    Zyout, Imad; Czajkowska, Joanna; Grzegorzek, Marcin

    2015-12-01

    The high number of false positives and the resulting number of avoidable breast biopsies are the major problems faced by current mammography Computer Aided Detection (CAD) systems. False positive reduction is not only a requirement for mass but also for calcification CAD systems which are currently deployed for clinical use. This paper tackles two problems related to reducing the number of false positives in the detection of all lesions and masses, respectively. Firstly, textural patterns of breast tissue have been analyzed using several multi-scale textural descriptors based on wavelet and gray level co-occurrence matrix. The second problem addressed in this paper is the parameter selection and performance optimization. For this, we adopt a model selection procedure based on Particle Swarm Optimization (PSO) for selecting the most discriminative textural features and for strengthening the generalization capacity of the supervised learning stage based on a Support Vector Machine (SVM) classifier. For evaluating the proposed methods, two sets of suspicious mammogram regions have been used. The first one, obtained from Digital Database for Screening Mammography (DDSM), contains 1494 regions (1000 normal and 494 abnormal samples). The second set of suspicious regions was obtained from database of Mammographic Image Analysis Society (mini-MIAS) and contains 315 (207 normal and 108 abnormal) samples. Results from both datasets demonstrate the efficiency of using PSO based model selection for optimizing both classifier hyper-parameters and parameters, respectively. Furthermore, the obtained results indicate the promising performance of the proposed textural features and more specifically, those based on co-occurrence matrix of wavelet image representation technique. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Recurrent/metastatic thyroid carcinomas false negative for serum thyroglobulin but positive by posttherapy I-131 whole body scans

    International Nuclear Information System (INIS)

    Park, Eun-Kyung; Lee, Dong Soo; Lee, Myung Chul; Chung, June-Key; Lim, Il Han; Park, Do Joon; Cho, Bo Youn

    2009-01-01

    Serum Tg and I-131 WBS have been used to detect recurrent and metastatic thyroid cancers postoperatively. Tg is known to be more sensitive than I-131 WBS, and therefore, false-negative WBS cases with elevated Tg levels are frequently found. However, the clinical characteristics of false-negative Tg cases with positive WBS have not been clarified. The authors evaluated 824 postoperative patients with differentiated thyroid carcinoma who underwent post-ablation/therapy I-131 WBS. Tg negativity was defined as a Tg level of ≤2 ng/mL without TgAb under thyroid-stimulating hormone stimulation. Remission, recurrence, and metastasis were confirmed using pathologic or clinically findings. Fifty-two patients (6.3%) with functioning metastasis and negativity for TgAb were Tg-negative and posttherapy I-131 WBS-positive (TgN group), and 128 patients with functioning metastases were Tg positive and WBS positive (TgP group). The TgN group consisted of 45 cases of cervical/mediastinal lymph node metastases (86.5%) and seven cases of distant metastasis to lung or bone by follow-up WBS. The TgN group demonstrated significantly higher profiles of regional involvement than the TgP group (P < 0.029). In 47 patients in the TgN group, metastatic uptake disappeared in 33, ameliorated in four, and persisted in ten during follow-up. A significant number of differentiated thyroid cancer patients were Tg-/TgAb-negative despite a positive WBS finding. Cervical and mediastinal lymph nodes were predominant sites of metastasis in the TgN group. WBS should be undertaken routinely as a complementary modality to detect functioning recurrence and metastasis regardless of serum Tg results. (orig.)

  11. SOX10-positive cells emerge in the rat pituitary gland during late embryogenesis and start to express S100β.

    Science.gov (United States)

    Ueharu, Hiroki; Yoshida, Saishu; Kanno, Naoko; Horiguchi, Kotaro; Nishimura, Naoto; Kato, Takako; Kato, Yukio

    2018-04-01

    In the pituitary gland, S100β-positive cells localize in the neurohypophysis and adenohypophysis but the lineage of the two groups remains obscure. S100β is often observed in many neural crest-derived cell types. Therefore, in this study, we investigate the origin of pituitary S100β-positive cells by immunohistochemistry for SOX10, a potent neural crest cell marker, using S100β-green fluorescence protein-transgenic rats. On embryonic day 21.5, a SOX10-positive cell population, which was also positive for the stem/progenitor cell marker SOX2, emerged in the pituitary stalk and posterior lobe and subsequently expanded to create a rostral-caudal gradient on postnatal day 3 (P3). Thereafter, SOX10-positive cells appeared in the intermediate lobe by P15, localizing to the boundary facing the posterior lobe, the gap between the lobule structures and the marginal cell layer, a pituitary stem/progenitor cell niche. Subsequently, there was an increase in SOX10/S100β double-positive cells; some of these cells in the gap between the lobule structures showed extended cytoplasm containing F-actin, indicating a feature of migration activity. The proportion of SOX10-positive cells in the postnatal anterior lobe was lower than 0.025% but about half of them co-localized with the pituitary-specific progenitor cell marker PROP1. Collectively, the present study identified that one of the lineages of S100β-positive cells is a SOX10-positive one and that SOX10-positive cells express pituitary stem/progenitor cell marker genes.

  12. Avoiding false positive antigen detection by flow cytometry on blood cell derived microparticles: the importance of an appropriate negative control.

    Directory of Open Access Journals (Sweden)

    Emerence Crompot

    Full Text Available Microparticles (MPs, also called microvesicles (MVs are plasma membrane-derived fragments with sizes ranging from 0.1 to 1μm. Characterization of these MPs is often performed by flow cytometry but there is no consensus on the appropriate negative control to use that can lead to false positive results.We analyzed MPs from platelets, B-cells, T-cells, NK-cells, monocytes, and chronic lymphocytic leukemia (CLL B-cells. Cells were purified by positive magnetic-separation and cultured for 48h. Cells and MPs were characterized using the following monoclonal antibodies (CD19,20 for B-cells, CD3,8,5,27 for T-cells, CD16,56 for NK-cells, CD14,11c for monocytes, CD41,61 for platelets. Isolated MPs were stained with annexin-V-FITC and gated between 300nm and 900nm. The latex bead technique was then performed for easy detection of MPs. Samples were analyzed by Transmission (TEM and Scanning Electron microscopy (SEM.Annexin-V positive events within a gate of 300-900nm were detected and defined as MPs. Our results confirmed that the characteristic antigens CD41/CD61 were found on platelet-derived-MPs validating our technique. However, for MPs derived from other cell types, we were unable to detect any antigen, although they were clearly expressed on the MP-producing cells in the contrary of several data published in the literature. Using the latex bead technique, we confirmed detection of CD41,61. However, the apparent expression of other antigens (already deemed positive in several studies was determined to be false positive, indicated by negative controls (same labeling was used on MPs from different origins.We observed that mother cell antigens were not always detected on corresponding MPs by direct flow cytometry or latex bead cytometry. Our data highlighted that false positive results could be generated due to antibody aspecificity and that phenotypic characterization of MPs is a difficult field requiring the use of several negative controls.

  13. [False positive results or what's the probability that a significant P-value indicates a true effect?

    Science.gov (United States)

    Cucherat, Michel; Laporte, Silvy

    2017-09-01

    The use of statistical test is central in the clinical trial. At the statistical level, obtaining a Pinformation about the plausibility of the existence of treatment effect. With "Pfalse positive is very high. This is the case if the power is low, if there is an inflation of the alpha risk or if the result is exploratory or chance discoveries. This possibility is important to take into consideration when interpreting the results of clinical trials in order to avoid pushing ahead significant results in appearance, but which are likely to be actually false positive results. Copyright © 2017 Société française de pharmacologie et de thérapeutique. Published by Elsevier Masson SAS. All rights reserved.

  14. False-positive result when a diphenylcarbazide spot test is used on trivalent chromium-passivated zinc surfaces

    DEFF Research Database (Denmark)

    Reveko, Valeriia; Lampert, Felix; Din, Rameez Ud

    2018-01-01

    chromium passivation on zinc; however, subsequent analysis by XPS could not confirm the presence of chromium in a hexavalent state. Conclusions Unintended oxidation of DPC induced by atmospheric corrosion is suggested as a possible reason for the false-positive reaction of the DPC test on a trivalent......A colorimetric 1,5-diphenylcarbazide (DPC)-based spot test can be used to identify hexavalent chromium on various metallic and leather surfaces. DPC testing on trivalent chromium-passivated zinc surfaces has unexpectedly given positive results in some cases, apparently indicating the presence...... of hexavalent chromium; however, the presence of hexavalent chromium has never been confirmed with more sensitive and accurate test methods. Objectives To examine the presence of hexavalent chromium on trivalent chromium-passivated zinc surfaces with a DPC-based spot test. Methods A colorimetric DPC spot test...

  15. False-positive axillary lymph node on F-18 FDG PET/CT due to moxibustion therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Shin Young; Lee, Sang Woo; Ahn, Byeong Cheol; Lee, Jae Tae [Kyungpook National University Hospital, Daegu (Korea, Republic of); Seo, Ji Hyoung [Inje University Haeundae Paik Hospital, Busan (Korea, Republic of)

    2010-12-15

    A 30-year-old female was diagnosed with papillary thyroid cancer and underwent total thyroidectomy and high-dose radioiodine ablation. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for recurrence detection of thyroid carcinoma was performed at 3 years after total thyroidectomy. Moxibustion is a traditional Chinese medicine therapy using moxa or the mugwort herb. Moxibustion is the burning of a small, thimble-sized, smoldering plug of dried leaves such as moxa or mugwort on the skin at an acupuncture point. Acupuncture and moxibustion induce hyperemia and a local inflammatory reaction. Complications associated with moxibustion such as skin bums or infection of the site have been reported previously. False-positive FDG uptake in PET may result from inflammation, infection, and variations in physiological uptake. In the present case, the hypermetabolic axillary lymph node disappeared without any treatment. Well-known of false-positive FDG uptake in axillary lymph noes such as arthritis of the upper extremity, extravasation of injected FDG, and vaccination were not found. Thus, left axillary lymph node uptake was

  16. False-positive axillary lymph node on F-18 FDG PET/CT due to moxibustion therapy

    International Nuclear Information System (INIS)

    Jeong, Shin Young; Lee, Sang Woo; Ahn, Byeong Cheol; Lee, Jae Tae; Seo, Ji Hyoung

    2010-01-01

    A 30-year-old female was diagnosed with papillary thyroid cancer and underwent total thyroidectomy and high-dose radioiodine ablation. F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for recurrence detection of thyroid carcinoma was performed at 3 years after total thyroidectomy. Moxibustion is a traditional Chinese medicine therapy using moxa or the mugwort herb. Moxibustion is the burning of a small, thimble-sized, smoldering plug of dried leaves such as moxa or mugwort on the skin at an acupuncture point. Acupuncture and moxibustion induce hyperemia and a local inflammatory reaction. Complications associated with moxibustion such as skin bums or infection of the site have been reported previously. False-positive FDG uptake in PET may result from inflammation, infection, and variations in physiological uptake. In the present case, the hypermetabolic axillary lymph node disappeared without any treatment. Well-known of false-positive FDG uptake in axillary lymph noes such as arthritis of the upper extremity, extravasation of injected FDG, and vaccination were not found. Thus, left axillary lymph node uptake was

  17. False Positive Findings on I-131 WBS and SPECT/CT in Patients with History of Thyroid Cancer: Case Series

    Directory of Open Access Journals (Sweden)

    Zeina C. Hannoush

    2017-01-01

    Full Text Available Introduction. Although whole body scan (WBS with I-131 is a highly sensitive tool for detecting normal thyroid tissue and metastasis of differentiated thyroid cancer (DTC, it is not specific. Additional information, provided by single photon emission computed tomography combined with X-ray computed tomography (SPECT/CT and by the serum thyroglobulin level, is extremely useful for the interpretation of findings. Case Presentation. We report four cases of false positive WBS in patients with DTC: ovarian uptake corresponding to an endometrioma, scrotal uptake due to a spermatocele, rib-cage uptake due to an old fracture, and hepatic and renal uptake secondary to a granuloma and simple cyst, respectively. Conclusions. Trapping, organification, and storage of iodine are more prominent in thyroid tissue but not specific. Physiologic sodium-iodine symporter expression in other tissues explains some, but not all, of the WBS false positive cases. Other proposed etiologies are accumulation of radioiodine in inflamed organs, metabolism of radiodinated thyroid hormone, presence of radioiodine in body fluids, and contamination. In our cases nonthyroidal pathologies were suspected since the imaging findings were not corroborated by an elevated thyroglobulin level, which is considered a reliable tumor marker for most well-differentiated thyroid cancers. Clinicians should be aware of the potential pitfalls of WBS in DTC to avoid incorrect management.

  18. Impact of intermediate mammography assessment on the likelihood of false-positive results in breast cancer screening programmes

    Energy Technology Data Exchange (ETDEWEB)

    Ascunce, Nieves [Public Health Institute, CIBERESP, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Instituto de Salud Publica, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Ederra, Maria; Delfrade, Josu; Erdozain, Nieves [Public Health Institute, CIBERESP, Navarra Breast Cancer Screening Programme, Pamplona (Spain); Baroja, Araceli [Fundacion Rioja Salud, Logrono (Spain); Zubizarreta, Raquel [Public Health and Planning Directorate, Health Office, Galician Breast Cancer Screening Programme, Galicia (Spain); Salas, Dolores [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia (Spain); Castells, Xavier [Mar Teaching Hospital, CIBERESP, Department of Clinical Epidemiology, Barcelona (Spain)

    2012-02-15

    Breast cancer screening is offered to 100% of the target population in Spain and intermediate mammograms (IMs) are sometimes indicated. This study was aimed at analysing the frequency of IMs, the factors determining their recommendation, and their impact on the risk of false-positive results and the detection rate. Data from 3,471,307 mammograms from Spanish breast cancer screening programmes were included. 3.36% of the mammograms were IMs. The factors associated with the use of IMs were age, initial screening, previous invasive tests, a familial history of breast cancer and use of hormone replacement therapy. In screening episodes with an IM, the probability of a false-positive result was 13.74% (95% CI: 13.43-14.05), almost double that in episodes without IMs (6.02%, 95% CI 5.99-6.05). In young women with previous invasive procedures, a familial history of breast cancer or hormone replacement therapy use who were undergoing their initial screen, this probability was lower when IMs were performed. IMs always increased the detection rate. The factors prompting IMs should be characterised so that radiologists can systematise their recommendations according to the presence of the factors maximising the benefits and minimising the adverse effects of this procedure. (orig.)

  19. Impact of intermediate mammography assessment on the likelihood of false-positive results in breast cancer screening programmes

    International Nuclear Information System (INIS)

    Ascunce, Nieves; Ederra, Maria; Delfrade, Josu; Erdozain, Nieves; Baroja, Araceli; Zubizarreta, Raquel; Salas, Dolores; Castells, Xavier

    2012-01-01

    Breast cancer screening is offered to 100% of the target population in Spain and intermediate mammograms (IMs) are sometimes indicated. This study was aimed at analysing the frequency of IMs, the factors determining their recommendation, and their impact on the risk of false-positive results and the detection rate. Data from 3,471,307 mammograms from Spanish breast cancer screening programmes were included. 3.36% of the mammograms were IMs. The factors associated with the use of IMs were age, initial screening, previous invasive tests, a familial history of breast cancer and use of hormone replacement therapy. In screening episodes with an IM, the probability of a false-positive result was 13.74% (95% CI: 13.43-14.05), almost double that in episodes without IMs (6.02%, 95% CI 5.99-6.05). In young women with previous invasive procedures, a familial history of breast cancer or hormone replacement therapy use who were undergoing their initial screen, this probability was lower when IMs were performed. IMs always increased the detection rate. The factors prompting IMs should be characterised so that radiologists can systematise their recommendations according to the presence of the factors maximising the benefits and minimising the adverse effects of this procedure. (orig.)

  20. Isolation of dendritic-cell-like S100β-positive cells in rat anterior pituitary gland.

    Science.gov (United States)

    Horiguchi, Kotaro; Fujiwara, Ken; Yoshida, Saishu; Higuchi, Masashi; Tsukada, Takehiro; Kanno, Naoko; Yashiro, Takashi; Tateno, Kozue; Osako, Shunji; Kato, Takako; Kato, Yukio

    2014-07-01

    S100β-protein-positive cells in the anterior pituitary gland appear to possess multifunctional properties. Because of their pleiotropic features, S100β-positive cells are assumed to be of a heterogeneous or even a non-pituitary origin. The observation of various markers has allowed these cells to be classified into populations such as stem/progenitor cells, epithelial cells, astrocytes and dendritic cells. The isolation and characterization of each heterogeneous population is a prerequisite for clarifying the functional character and origin of the cells. We attempt to isolate two of the subpopulations of S100β-positive cells from the anterior lobe. First, from transgenic rats that express green fluorescent protein (GFP) driven by the S100β protein promoter, we fractionate GFP-positive cells with a cell sorter and culture them so that they can interact with laminin, a component of the extracellular matrix. We observe that one morphological type of GFP-positive cells possesses extended cytoplasmic processes and shows high adhesiveness to laminin (process type), whereas the other is round in shape and exhibits low adherence to laminin (round type). We successfully isolate cells of the round type from the cultured GFP-positive cells by taking advantage of their low affinity to laminin and then measure mRNA levels of the two cell types by real-time polymerase chain reaction. The resultant data show that the process type expresses vimentin (mesenchymal cell marker) and glial fibrillary acidic protein (astrocyte marker). The round type expresses dendritic cell markers, CD11b and interleukin-6. Thus, we found a method for isolating dendritic-cell-like S100β-positive cells by means of their property of adhering to laminin.

  1. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    International Nuclear Information System (INIS)

    Désert, Jean-Michel; Brown, Timothy M.; Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W.; Bryson, Stephen T.; Borucki, William J.; Knutson, Heather A.; Batalha, Natalie M.; Deming, Drake; Ford, Eric B.; Fortney, Jonathan J.; Gilliland, Ronald L.; Seager, Sara

    2015-01-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  2. LOW FALSE POSITIVE RATE OF KEPLER CANDIDATES ESTIMATED FROM A COMBINATION OF SPITZER AND FOLLOW-UP OBSERVATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Désert, Jean-Michel; Brown, Timothy M. [CASA, Department of Astrophysical and Planetary Sciences, University of Colorado, 389-UCB, Boulder, CO 80309 (United States); Charbonneau, David; Torres, Guillermo; Fressin, François; Ballard, Sarah; Latham, David W. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Bryson, Stephen T.; Borucki, William J. [NASA Ames Research Center, Moffett Field, CA 94035 (United States); Knutson, Heather A. [Division of Geological and Planetary Sciences, California Institute of Technology, Pasadena, CA 91125 (United States); Batalha, Natalie M. [San Jose State University, San Jose, CA 95192 (United States); Deming, Drake [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Ford, Eric B. [University of Florida, Gainesville, FL 32611 (United States); Fortney, Jonathan J. [Department of Astronomy and Astrophysics, University of California, Santa Cruz, CA 95064 (United States); Gilliland, Ronald L. [Center for Exoplanets and Habitable Worlds, The Pennsylvania State University, University Park, PA 16802 (United States); Seager, Sara, E-mail: desert@colorado.edu [Massachusetts Institute of Technology, Cambridge, MA 02159 (United States)

    2015-05-01

    NASA’s Kepler mission has provided several thousand transiting planet candidates during the 4 yr of its nominal mission, yet only a small subset of these candidates have been confirmed as true planets. Therefore, the most fundamental question about these candidates is the fraction of bona fide planets. Estimating the rate of false positives of the overall Kepler sample is necessary to derive the planet occurrence rate. We present the results from two large observational campaigns that were conducted with the Spitzer Space Telescope during the the Kepler mission. These observations are dedicated to estimating the false positive rate (FPR) among the Kepler candidates. We select a sub-sample of 51 candidates, spanning wide ranges in stellar, orbital, and planetary parameter space, and we observe their transits with Spitzer at 4.5 μm. We use these observations to measures the candidate’s transit depths and infrared magnitudes. An authentic planet produces an achromatic transit depth (neglecting the modest effect of limb darkening). Conversely a bandpass-dependent depth alerts us to the potential presence of a blending star that could be the source of the observed eclipse: a false positive scenario. For most of the candidates (85%), the transit depths measured with Kepler are consistent with the transit depths measured with Spitzer as expected for planetary objects, while we find that the most discrepant measurements are due to the presence of unresolved stars that dilute the photometry. The Spitzer constraints on their own yield FPRs between 5% and depending on the Kepler Objects of Interest. By considering the population of the Kepler field stars, and by combining follow-up observations (imaging) when available, we find that the overall FPR of our sample is low. The measured upper limit on the FPR of our sample is 8.8% at a confidence level of 3σ. This observational result, which uses the achromatic property of planetary transit signals that is not investigated

  3. Susceptibility of coagulase positive staphylococci isolated from cow's mammary gland to antibacterial drugs

    Directory of Open Access Journals (Sweden)

    Savić-Rajić Nataša

    2009-01-01

    Full Text Available Coagulase positive staphylococci are one of the most common causes of chronic udder infection. Indiscriminate use of antimicrobial drugs and their presence in the environment where animals live has led to coagulase positive staphylococci strains resistant to antimicrobial means. Proper and timely treatment of sub-clinical mastitis, based on the most effective use of antimicrobial drugs, is the key to good health of the milk herd. The aim was to determine the antimicrobial efficacy of selected assets in relation to coagulase positive staphylococci isolated from samples of milk taken from individual udder quarters of cows in cases of udder infection from three farms with different mastitis prevalence. From a total of 9245 samples of milk taken from individual udder quarters of cows from three farms, 852 strains isolated were coagulase positive staphylococci. Coagulase positive staphylococci were isolated on blood agar and identified on the basis of macro-morphological characteristics and the coagulase and catalase test. The sensitivity of the coagulase positive staphylococci was tested by the Kirby Bauer agar diffusion method with the following antimicrobials: penicillin 6µg, amoxicillin / sulbactam (20 +10µg, cloxacillin 25 µg, cefalexin 30 µg, ceftiofur 30µg, linkomycin 15µg, 30 µg gentamycin and tetracycline 30 µg. Sensitivity testing of coagulase positive staphylococci, isolated in cases of intramammary cow infections, established a high degree of sensitivity in vitro towards penicilinasa resistant drugs (amoxicillin-sublactam, cloxacilin, cephalosporins of the first and third generations and linkomycin. The highest levels of resistance to penicillin (70.4% were found on a farm with a moderate prevalence of udder infection, then on the farm with the highest prevalence of intramammary infections (60.2% and the lowest on the farm with controlled levels of resistance of infection (43.7%. .

  4. Trial sequential analysis reveals insufficient information size and potentially false positive results in many meta-analyses

    DEFF Research Database (Denmark)

    Brok, J.; Thorlund, K.; Gluud, C.

    2008-01-01

    in 80% (insufficient information size). TSA(15%) and TSA(LBHIS) found that 95% and 91% had absence of evidence. The remaining nonsignificant meta-analyses had evidence of lack of effect. CONCLUSION: TSA reveals insufficient information size and potentially false positive results in many meta......OBJECTIVES: To evaluate meta-analyses with trial sequential analysis (TSA). TSA adjusts for random error risk and provides the required number of participants (information size) in a meta-analysis. Meta-analyses not reaching information size are analyzed with trial sequential monitoring boundaries...... analogous to interim monitoring boundaries in a single trial. STUDY DESIGN AND SETTING: We applied TSA on meta-analyses performed in Cochrane Neonatal reviews. We calculated information sizes and monitoring boundaries with three different anticipated intervention effects of 30% relative risk reduction (TSA...

  5. False-positive liver scans due to portal hypertension: correlation with percutaneous transhepatic portograms in 33 patients

    International Nuclear Information System (INIS)

    Takayasu, K.; Moriyama, N.; Suzuki, M.; Yamada, T.; Fukutake, T.; Shima, Y.; Kobayashi, C.; Musha, H.; Okuda, K.

    1983-01-01

    Tc-99m-phytate scanning of the liver and percutaneous transhepatic catheterization of the portal vein were performed in 33 patients--26 with cirrhosis, 3 with chronic active hepatitis, 2 with idiopathic portal hypertension, and 2 with unresolved acute hepatitis. A discrete defect in the porta hepatis area was seen in 6 of 28 patients who had portal vein pressure above 200 mm H2O. In 5 of the 6 patients with a false-positive scan, the umbilical portion of the left portal vein branch was dilated (larger than 25 x 20 mm) on the portogram, with or without a patent paraumbilical vein. The anatomical basis of this phenomenon is discussed, and it is suggested that this area be given special attention

  6. Minimotif Miner 3.0: database expansion and significantly improved reduction of false-positive predictions from consensus sequences.

    Science.gov (United States)

    Mi, Tian; Merlin, Jerlin Camilus; Deverasetty, Sandeep; Gryk, Michael R; Bill, Travis J; Brooks, Andrew W; Lee, Logan Y; Rathnayake, Viraj; Ross, Christian A; Sargeant, David P; Strong, Christy L; Watts, Paula; Rajasekaran, Sanguthevar; Schiller, Martin R

    2012-01-01

    Minimotif Miner (MnM available at http://minimotifminer.org or http://mnm.engr.uconn.edu) is an online database for identifying new minimotifs in protein queries. Minimotifs are short contiguous peptide sequences that have a known function in at least one protein. Here we report the third release of the MnM database which has now grown 60-fold to approximately 300,000 minimotifs. Since short minimotifs are by their nature not very complex we also summarize a new set of false-positive filters and linear regression scoring that vastly enhance minimotif prediction accuracy on a test data set. This online database can be used to predict new functions in proteins and causes of disease.

  7. Benign thyroid and neck lesions mimicking malignancy with false positive findings on positron emission tomography-computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ye Ri; Kim, Shin Young; Lee, Sang Mi [Soonchunhyang University Cheonan Hospital, Cheonan (Korea, Republic of); Lee, Deuk Young [Dept. of Surgery, Younsei Angelot Women' s Clinic, Cheonan (Korea, Republic of)

    2017-02-15

    The increasing use of positron emission tomography-computed tomography (PET/CT) has led to the frequent detection of incidental thyroid and neck lesions with increased 18F-deoxyglucose (FDG) uptake. Although lesions with increased FDG uptake are commonly assumed to be malignant, benign lesions may also exhibit increased uptake. The purpose of this pictorial essay is to demonstrate that benign thyroid and neck lesions can produce false-positive findings on PET/CT, and to identify various difficulties in interpretation. It is crucial to be aware that differentiating between benign and malignant lesions is difficult in a considerable proportion of cases, when relying only on PET/CT findings. Correlation of PET/CT findings with additional imaging modalities is essential to avoid misdiagnosis.

  8. Systematic hybrid LOH: a new method to reduce false positives and negatives during screening of yeast gene deletion libraries

    DEFF Research Database (Denmark)

    Alvaro, D.; Sunjevaric, I.; Reid, R. J.

    2006-01-01

    We have developed a new method, systematic hybrid loss of heterozygosity, to facilitate genomic screens utilizing the yeast gene deletion library. Screening is performed using hybrid diploid strains produced through mating the library haploids with strains from a different genetic background......, to minimize the contribution of unpredicted recessive genetic factors present in the individual library strains. We utilize a set of strains where each contains a conditional centromere construct on one of the 16 yeast chromosomes that allows the destabilization and selectable loss of that chromosome. After...... complementation of any spurious recessive mutations in the library strain, facilitating attribution of the observed phenotype to the documented gene deletion and dramatically reducing false positive results commonly obtained in library screens. The systematic hybrid LOH method can be applied to virtually any...

  9. Reproducibility of mammary gland structure during repeat setups in a supine position.

    NARCIS (Netherlands)

    Klein Zeggelink, W.F.; Deurloo, E.E.; Muller, J.M.; Schultze Kool, L.J.; Gilhuijs, K.G.

    2002-01-01

    PURPOSE: In breast conserving therapy, complete excision of the tumor with an acceptable cosmetic outcome depends on accurate localization in terms of both the position of the lesion and its extent. We hypothesize that preoperative contrast-enhanced magnetic resonance (MR) imaging of the patient in

  10. Automated detection of masses on whole breast volume ultrasound scanner: false positive reduction using deep convolutional neural network

    Science.gov (United States)

    Hiramatsu, Yuya; Muramatsu, Chisako; Kobayashi, Hironobu; Hara, Takeshi; Fujita, Hiroshi

    2017-03-01

    Breast cancer screening with mammography and ultrasonography is expected to improve sensitivity compared with mammography alone, especially for women with dense breast. An automated breast volume scanner (ABVS) provides the operator-independent whole breast data which facilitate double reading and comparison with past exams, contralateral breast, and multimodality images. However, large volumetric data in screening practice increase radiologists' workload. Therefore, our goal is to develop a computer-aided detection scheme of breast masses in ABVS data for assisting radiologists' diagnosis and comparison with mammographic findings. In this study, false positive (FP) reduction scheme using deep convolutional neural network (DCNN) was investigated. For training DCNN, true positive and FP samples were obtained from the result of our initial mass detection scheme using the vector convergence filter. Regions of interest including the detected regions were extracted from the multiplanar reconstraction slices. We investigated methods to select effective FP samples for training the DCNN. Based on the free response receiver operating characteristic analysis, simple random sampling from the entire candidates was most effective in this study. Using DCNN, the number of FPs could be reduced by 60%, while retaining 90% of true masses. The result indicates the potential usefulness of DCNN for FP reduction in automated mass detection on ABVS images.

  11. Public health consequences of a false-positive laboratory test result for Brucella--Florida, Georgia, and Michigan, 2005.

    Science.gov (United States)

    2008-06-06

    Human brucellosis, a nationally notifiable disease, is uncommon in the United States. Most human cases have occurred in returned travelers or immigrants from regions where brucellosis is endemic, or were acquired domestically from eating illegally imported, unpasteurized fresh cheeses. In January 2005, a woman aged 35 years who lived in Nassau County, Florida, received a diagnosis of brucellosis, based on results of a Brucella immunoglobulin M (IgM) enzyme immunoassay (EIA) performed in a commercial laboratory using analyte specific reagents (ASRs); this diagnosis prompted an investigation of dairy products in two other states. Subsequent confirmatory antibody testing by Brucella microagglutination test (BMAT) performed at CDC on the patient's serum was negative. The case did not meet the CDC/Council of State and Territorial Epidemiologists' (CSTE) definition for a probable or confirmed brucellosis case, and the initial EIA result was determined to be a false positive. This report summarizes the case history, laboratory findings, and public health investigations. CDC recommends that Brucella serology testing only be performed using tests cleared or approved by the Food and Drug Administration (FDA) or validated under the Clinical Laboratory Improvement Amendments (CLIA) and shown to reliably detect the presence of Brucella infection. Results from these tests should be considered supportive evidence for recent infection only and interpreted in the context of a clinically compatible illness and exposure history. EIA is not considered a confirmatory Brucella antibody test; positive screening test results should be confirmed by Brucella-specific agglutination (i.e., BMAT or standard tube agglutination test) methods.

  12. Easy fix for clinical laboratories for the false-positive defect with the Abbott AxSym total beta-hCG test.

    Science.gov (United States)

    Cole, Laurence A; Khanlian, Sarah A

    2004-05-01

    False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.

  13. Computer-aided mass detection in mammography: False positive reduction via gray-scale invariant ranklet texture features

    International Nuclear Information System (INIS)

    Masotti, Matteo; Lanconelli, Nico; Campanini, Renato

    2009-01-01

    In this work, gray-scale invariant ranklet texture features are proposed for false positive reduction (FPR) in computer-aided detection (CAD) of breast masses. Two main considerations are at the basis of this proposal. First, false positive (FP) marks surviving our previous CAD system seem to be characterized by specific texture properties that can be used to discriminate them from masses. Second, our previous CAD system achieves invariance to linear/nonlinear monotonic gray-scale transformations by encoding regions of interest into ranklet images through the ranklet transform, an image transformation similar to the wavelet transform, yet dealing with pixels' ranks rather than with their gray-scale values. Therefore, the new FPR approach proposed herein defines a set of texture features which are calculated directly from the ranklet images corresponding to the regions of interest surviving our previous CAD system, hence, ranklet texture features; then, a support vector machine (SVM) classifier is used for discrimination. As a result of this approach, texture-based information is used to discriminate FP marks surviving our previous CAD system; at the same time, invariance to linear/nonlinear monotonic gray-scale transformations of the new CAD system is guaranteed, as ranklet texture features are calculated from ranklet images that have this property themselves by construction. To emphasize the gray-scale invariance of both the previous and new CAD systems, training and testing are carried out without any in-between parameters' adjustment on mammograms having different gray-scale dynamics; in particular, training is carried out on analog digitized mammograms taken from a publicly available digital database, whereas testing is performed on full-field digital mammograms taken from an in-house database. Free-response receiver operating characteristic (FROC) curve analysis of the two CAD systems demonstrates that the new approach achieves a higher reduction of FP marks

  14. False Positive Stress Testing: Does Endothelial Vascular Dysfunction Contribute to ST-Segment Depression in Women? A Pilot Study.

    Science.gov (United States)

    Sharma, Shilpa; Mehta, Puja K; Arsanjani, Reza; Sedlak, Tara; Hobel, Zachary; Shufelt, Chrisandra; Jones, Erika; Kligfield, Paul; Mortara, David; Laks, Michael; Diniz, Marcio; Bairey Merz, C Noel

    2018-06-19

    The utility of exercise-induced ST-segment depression for diagnosing ischemic heart disease (IHD) in women is unclear. Based on evidence that IHD pathophysiology in women involves coronary vascular dysfunction, we hypothesized that coronary vascular dysfunction contributes to exercise electrocardiography (Ex-ECG) ST-depression in the absence of obstructive CAD, so-called "false positive" results. We tested our hypothesis in a pilot study evaluating the relationship between peripheral vascular endothelial function and Ex-ECG. Twenty-nine asymptomatic women without cardiac risk factors underwent maximal Bruce protocol exercise treadmill testing and peripheral endothelial function assessment using peripheral arterial tonometry (Itamar EndoPAT 2000) to measure reactive hyperemia index (RHI). The relationship between RHI and Ex-ECG ST-segment depression was evaluated using logistic regression and differences in subgroups using two-tailed t-tests. Mean age was 54 ± 7 years, body mass index 25 ± 4 kg/m 2 , and RHI 2.51 ± 0.66. Three women (10%) had RHI less than 1.68, consistent with abnormal peripheral endothelial function, while 18 women (62%) met criteria for a positive Ex-ECG based on ST-segment depression in contiguous leads. Women with and without ST-segment depression had similar baseline and exercise vital signs, metabolic equivalents (METS) achieved, and RHI (all p>0.05). RHI did not predict ST-segment depression. Our pilot study demonstrates a high prevalence of exercise-induced ST-segment depression in asymptomatic, middle-aged, overweight women. Peripheral vascular endothelial dysfunction did not predict Ex-ECG ST-segment depression. Further work is needed to investigate the utility of vascular endothelial testing and Ex-ECG for IHD diagnostic and management purposes in women. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Feature-guided analysis for reduction of false positives in CAD of polyps for computed tomographic colonography

    International Nuclear Information System (INIS)

    Naeppi, Janne; Yoshida, Hiroyuki

    2003-01-01

    We evaluated the effect of our novel technique of feature-guided analysis of polyps on the reduction of false-positive (FP) findings generated by our computer-aided diagnosis (CAD) scheme for the detection of polyps from computed tomography colonographic data sets. The detection performance obtained by use of feature-guided analysis in the segmentation and feature analysis of polyp candidates was compared with that obtained by use of our previously employed fuzzy clustering technique. We also evaluated the effect of a feature called modified gradient concentration (MGC) on the detection performance. A total of 144 data sets, representing prone and supine views of 72 patients that included 14 patients with 21 colorectal polyps 5-25 mm in diameter, were used in the evaluation. At a 100% by-patient (95% by-polyp) detection sensitivity, the FP rate of our CAD scheme with feature-guided analysis based on round-robin evaluation was 1.3 (1.5) FP detections per patient. This corresponds to a 70-75 % reduction in the number of FPs obtained by use of fuzzy clustering at the same sensitivity levels. Application of the MGC feature instead of our previously used gradient concentration feature did not improve the detection result. The results indicate that feature-guided analysis is useful for achieving high sensitivity and a low FP rate in our CAD scheme

  16. Selective activation around the left occipito-temporal sulcus for words relative to pictures: individual variability or false positives?

    Science.gov (United States)

    Wright, Nicholas D; Mechelli, Andrea; Noppeney, Uta; Veltman, Dick J; Rombouts, Serge A R B; Glensman, Janice; Haynes, John-Dylan; Price, Cathy J

    2008-08-01

    We used high-resolution fMRI to investigate claims that learning to read results in greater left occipito-temporal (OT) activation for written words relative to pictures of objects. In the first experiment, 9/16 subjects performing a one-back task showed activation in > or =1 left OT voxel for words relative to pictures (P or =1 left OT voxel for words relative to pictures. However, at this low statistical threshold false positives need to be excluded. The semantic decision paradigm was therefore repeated, within subject, in two different scanners (1.5 and 3 T). Both scanners consistently localised left OT activation for words relative to fixation and pictures relative to words, but there were no consistent effects for words relative to pictures. Finally, in a third experiment, we minimised the voxel size (1.5 x 1.5 x 1.5 mm(3)) and demonstrated a striking concordance between the voxels activated for words and pictures, irrespective of task (naming vs. one-back) or script (English vs. Hebrew). In summary, although we detected differential activation for words relative to pictures, these effects: (i) do not withstand statistical rigour; (ii) do not replicate within or between subjects; and (iii) are observed in voxels that also respond to pictures of objects. Our findings have implications for the role of left OT activation during reading. More generally, they show that studies using low statistical thresholds in single subject analyses should correct the statistical threshold for the number of comparisons made or replicate effects within subject. (c) 2007 Wiley-Liss, Inc.

  17. Interval Breast Cancer Rates and Histopathologic Tumor Characteristics after False-Positive Findings at Mammography in a Population-based Screening Program.

    Science.gov (United States)

    Hofvind, Solveig; Sagstad, Silje; Sebuødegård, Sofie; Chen, Ying; Roman, Marta; Lee, Christoph I

    2018-04-01

    Purpose To compare rates and tumor characteristics of interval breast cancers (IBCs) detected after a negative versus false-positive screening among women participating in the Norwegian Breast Cancer Screening Program. Materials and Methods The Cancer Registry Regulation approved this retrospective study. Information about 423 445 women aged 49-71 years who underwent 789 481 full-field digital mammographic screening examinations during 2004-2012 was extracted from the Cancer Registry of Norway. Rates and odds ratios of IBC among women with a negative (the reference group) versus a false-positive screening were estimated by using logistic regression models adjusted for age at diagnosis and county of residence. Results A total of 1302 IBCs were diagnosed after 789 481 screening examinations, of which 7.0% (91 of 1302) were detected among women with a false-positive screening as the most recent breast imaging examination before detection. By using negative screening as the reference, adjusted odds ratios of IBCs were 3.3 (95% confidence interval [CI]: 2.6, 4.2) and 2.8 (95% CI: 1.8, 4.4) for women with a false-positive screening without and with needle biopsy, respectively. Women with a previous negative screening had a significantly lower proportion of tumors that were 10 mm or less (14.3% [150 of 1049] vs 50.0% [seven of 14], respectively; P false-positive screening with benign biopsy. A retrospective review of the screening mammographic examinations identified 42.9% (39 of 91) of the false-positive cases to be the same lesion as the IBC. Conclusion By using a negative screening as the reference, a false-positive screening examination increased the risk of an IBC three-fold. The tumor characteristics of IBC after a negative screening were less favorable compared with those detected after a previous false-positive screening. © RSNA, 2017 Online supplemental material is available for this article.

  18. Biological false-positive venereal disease research laboratory test in cerebrospinal fluid in the diagnosis of neurosyphilis - a case-control study.

    Science.gov (United States)

    Zheng, S; Lin, R J; Chan, Y H; Ngan, C C L

    2018-03-01

    There is no clear consensus on the diagnosis of neurosyphilis. The Venereal Disease Research Laboratory (VDRL) test from cerebrospinal fluid (CSF) has traditionally been considered the gold standard for diagnosing neurosyphilis but is widely known to be insensitive. In this study, we compared the clinical and laboratory characteristics of true-positive VDRL-CSF cases with biological false-positive VDRL-CSF cases. We retrospectively identified cases of true and false-positive VDRL-CSF across a 3-year period received by the Immunology and Serology Laboratory, Singapore General Hospital. A biological false-positive VDRL-CSF is defined as a reactive VDRL-CSF with a non-reactive Treponema pallidum particle agglutination (TPPA)-CSF and/or negative Line Immuno Assay (LIA)-CSF IgG. A true-positive VDRL-CSF is a reactive VDRL-CSF with a concordant reactive TPPA-CSF and/or positive LIA-CSF IgG. During the study period, a total of 1254 specimens underwent VDRL-CSF examination. Amongst these, 60 specimens from 53 patients tested positive for VDRL-CSF. Of the 53 patients, 42 (79.2%) were true-positive cases and 11 (20.8%) were false-positive cases. In our setting, a positive non-treponemal serology has 97.6% sensitivity, 100% specificity, 100% positive predictive value and 91.7% negative predictive value for a true-positive VDRL-CSF based on our laboratory definition. HIV seropositivity was an independent predictor of a true-positive VDRL-CSF. Biological false-positive VDRL-CSF is common in a setting where patients are tested without first establishing a serological diagnosis of syphilis. Serological testing should be performed prior to CSF evaluation for neurosyphilis. © 2017 European Academy of Dermatology and Venereology.

  19. SU-G-BRB-03: Assessing the Sensitivity and False Positive Rate of the Integrated Quality Monitor (IQM) Large Area Ion Chamber to MLC Positioning Errors

    Energy Technology Data Exchange (ETDEWEB)

    Boehnke, E McKenzie; DeMarco, J; Steers, J; Fraass, B [Cedars-Sinai Medical Center, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To examine both the IQM’s sensitivity and false positive rate to varying MLC errors. By balancing these two characteristics, an optimal tolerance value can be derived. Methods: An un-modified SBRT Liver IMRT plan containing 7 fields was randomly selected as a representative clinical case. The active MLC positions for all fields were perturbed randomly from a square distribution of varying width (±1mm to ±5mm). These unmodified and modified plans were measured multiple times each by the IQM (a large area ion chamber mounted to a TrueBeam linac head). Measurements were analyzed relative to the initial, unmodified measurement. IQM readings are analyzed as a function of control points. In order to examine sensitivity to errors along a field’s delivery, each measured field was divided into 5 groups of control points, and the maximum error in each group was recorded. Since the plans have known errors, we compared how well the IQM is able to differentiate between unmodified and error plans. ROC curves and logistic regression were used to analyze this, independent of thresholds. Results: A likelihood-ratio Chi-square test showed that the IQM could significantly predict whether a plan had MLC errors, with the exception of the beginning and ending control points. Upon further examination, we determined there was ramp-up occurring at the beginning of delivery. Once the linac AFC was tuned, the subsequent measurements (relative to a new baseline) showed significant (p <0.005) abilities to predict MLC errors. Using the area under the curve, we show the IQM’s ability to detect errors increases with increasing MLC error (Spearman’s Rho=0.8056, p<0.0001). The optimal IQM count thresholds from the ROC curves are ±3%, ±2%, and ±7% for the beginning, middle 3, and end segments, respectively. Conclusion: The IQM has proven to be able to detect not only MLC errors, but also differences in beam tuning (ramp-up). Partially supported by the Susan Scott Foundation.

  20. Malaria rapid diagnostic tests: Plasmodium falciparum infections with high parasite densities may generate false positive Plasmodium vivax pLDH lines

    Directory of Open Access Journals (Sweden)

    van Esbroeck Marjan

    2010-07-01

    Full Text Available Abstract Background Most malaria rapid diagnostic tests (RDTs detect Plasmodium falciparum and an antigen common to the four species. Plasmodium vivax-specific RDTs target P. vivax-specific parasite lactate dehydrogenase (Pv-pLDH. Previous observations of false positive Pv-pLDH test lines in P. falciparum samples incited to the present study, which assessed P. vivax-specific RDTs for the occurrence of false positive Pv-pLDH lines in P. falciparum samples. Methods Nine P. vivax-specific RDTs were tested with 85 P. falciparum samples of high (≥2% parasite density. Mixed P. falciparum/P. vivax infections were ruled out by real-time PCR. The RDTs included two-band (detecting Pv-pLDH, three-band (detecting P. falciparum-antigen and Pv-pLDH and four-band RDTs (detecting P. falciparum, Pv-pLDH and pan-pLDH. Results False positive Pv-pLDH lines were observed in 6/9 RDTs (including two- three- and four-band RDTs. They occurred in the individual RDT brands at frequencies ranging from 8.2% to 29.1%. For 19/85 samples, at least two RDT brands generated a false positive Pv-pLDH line. Sixteen of 85 (18.8% false positive lines were of medium or strong line intensity. There was no significant relation between false positive results and parasite density or geographic origin of the samples. Conclusion False positive Pv-pLDH lines in P. falciparum samples with high parasite density occurred in 6/9 P. vivax-specific RDTs. This is of concern as P. falciparum and P. vivax are co-circulating in many regions. The diagnosis of life-threatening P. falciparum malaria may be missed (two-band Pv-pLDH RDT, or the patient may be treated incorrectly with primaquine (three- or four-band RDTs.

  1. Retroperitoneal Endometriosis: A Possible Cause of False Positive Finding at 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Maffione, Anna Margherita; Panzavolta, Riccardo; Lisato, Laura Camilla; Ballotta, Maria; D'Isanto, Mariangela Zanforlini; Rubello, Domenico

    2015-01-01

    Endometriosis is a frequent and clinically relevant problem in young women. Laparoscopy is still the gold standard for the diagnosis of endometriosis, but frequently both morphologic and functional imaging techniques are involved in the diagnostic course before achieving a conclusive diagnosis. We present a case of a patient affected by infiltrating retroperitoneal endometriosis falsely interpreted as a malignant mass by contrast-enhanced magnetic resonance imaging and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography

  2. Mammary gland-specific nuclear factor activity is positively regulated by lactogenic hormones and negatively by milk stasis.

    Science.gov (United States)

    Schmitt-Ney, M; Happ, B; Hofer, P; Hynes, N E; Groner, B

    1992-12-01

    The mammary gland-specific nuclear factor (MGF) is a crucial contributor to the regulation of transcription from the beta-casein gene promoter. The beta-casein gene encodes a major milk protein, which is expressed in mammary epithelial cells during lactation and can be induced by lactogenic hormones in the clonal mammary epithelial cell line HC11. We have investigated the specific DNA-binding activity of MGF in mammary epithelial cells in vivo and in vitro. Comparison of MGF in HC11 cells and mammary gland cells from lactating mice revealed molecules with identical DNA-binding properties. Bandshift and UV cross-linking experiments indicated that MGF in HC11 cells has a higher mol wt than MGF found in mice. Little MGF activity was detected in nuclear extracts from HC11 cells cultured in the absence of lactogenic hormones. Lactogenic hormone treatment of HC11 cells led to a strong induction of MGF activity. The induction of MGF activity as well as utilization of the beta-casein promoter were suppressed when epidermal growth factor was present in the tissue culture medium simultaneously with the lactogenic hormones. In lactating animals, MGF activity is regulated by suckling, milk stasis, and systemic hormone signals. The mammary glands from maximally lactating animals, 16 days postpartum, contain drastically reduced MGF activity after removal of the pups for only 8 h. The down-regulation of MGF by pup withdrawal was slower in early lactation, 6 days postpartum. We also investigated the relative contributions of local signals, generated by milk stasis, and systemic hormone signals to the regulation of MGF activity. The access to one row of mammary glands of lactating mothers was denied to the pups for 24 h. High levels of MGF were found in the accessible mammary glands, and intermediate levels of MGF were found in the inaccessible glands of the same mouse. Very low MGF levels were detected when the pups were removed from the dams for 24 h. We conclude that systemic as

  3. K5/K14-positive cells contribute to salivary gland-like breast tumors with myoepithelial differentiation

    DEFF Research Database (Denmark)

    Boecker, Werner; Stenman, Goeran; Loening, Thomas

    2013-01-01

    different cell lineages and define their cellular hierarchy in tumors with myoepithelial differentiation. isTILT analysis of a series of 28 breast, salivary, and lacrimal gland tumors, including pleomorphic adenomas (n=8), epithelial-myoepithelial tumors (n=9), and adenoid cystic carcinomas (n=11) revealed...... heterologeous cell differentiations such as squamous and mesenchymal progenies. p63 was co-expressed with K5/K14 in basal-like progenitor cells, myoepithelial, and squamous cells but not in glandular cells. Our results show that the corresponding counterpart tumors of breast and salivary/lacrimal glands have....... For that reason, we performed an in situ triple immunofluorescence lineage/differentiation tracing (isTILT) and qRT-PCR study of basal (K5/K14), glandular (K7/K8/18), and epidermal-specific squamous (K10) keratins, p63, and smooth muscle actin (SMA; myoepithelial marker) with the aim to construct and trace...

  4. False positive or negative results of shear-wave elastography in differentiating benign from malignant breast masses: analysis of clinical and ultrasonographic characteristics.

    Science.gov (United States)

    Kim, Mi Young; Choi, Nami; Yang, Jung-Hyun; Yoo, Young Bum; Park, Kyoung Sik

    2015-10-01

    Shear-wave elastography (SWE) has the potential to improve diagnostic performance of conventional ultrasound (US) in differentiating benign from malignant breast masses. To investigate false positive or negative results of SWE in differentiating benign from malignant breast masses and to analyze clinical and imaging characteristics of the masses with false SWE findings. From May to October 2013, 166 breast lesions of 164 consecutive women (mean age, 45.3 ± 10.1 years) who had been scheduled for biopsy were included. Conventional US and SWE were performed in all women before biopsy. Clinical, ultrasonographic morphologic features and SWE parameters (pattern classification and standard deviation [SD]) were recorded and compared with the histopathology results. Patient and lesion factors in the "true" and "false" groups were compared. Of the 166 masses, 118 (71.1%) were benign and 48 (28.9%) were malignant. False SWE features were more frequently observed in benign masses. False positive rates of benign masses and false negative rates of malignancy were 53% and 8.2%, respectively, using SWE pattern analysis and were 22.4% and 10.3%, respectively, using SD values. A lesion boundary of the masses on US (P = 0.039) and younger patient age (P = 0.047) were significantly associated with false SWE findings. These clinical and ultrasonographic features need to be carefully evaluated in performance and interpretation of SWE examinations. © The Foundation Acta Radiologica 2014.

  5. Small Intestinal Bacterial Overgrowth May Increase the Likelihood of Lactose and Sorbitol but not Fructose Intolerance False Positive Diagnosis.

    Science.gov (United States)

    Perets, Tsachi Tsadok; Hamouda, Dalal; Layfer, Olga; Ashorov, Olga; Boltin, Doron; Levy, Sigal; Niv, Yaron; Dickman, Ram

    2017-08-01

    Small intestinal bacterial overgrowth (SIBO) is defined as a bacterial count of more than 10 5 colony-forming units per milliliter in duodenal aspirate. It shares many symptoms with carbohydrate intolerance, which makes the clinical distinction of the disorders difficult. The aim of the study was to examine the relationship between a positive carbohydrate breath test and the presence of SIBO suggested by a positive lactulose hydrogen breath test. The electronic database of the gastroenterology laboratory of a tertiary medical center was searched for all patients clinically tested for SIBO in 2012-2013 for whom previous results for lactose, fructose, and/or sorbitol breath test were available. The correlation between positive findings for carbohydrate intolerance and for SIBO was statistically analyzed. The study group included 349 patients, 231 female and 118 male, of mean age 53±19 years. All had symptoms of abdominal bloating and gas. There was a statistically significant difference in rates of a positive breath test for lactose and sorbitol at ≤90 minutes between patients who were positive and negative for SIBO [χ 2 (1)=12.8, p <0.01 and χ 2 (1)=9.5, p <0.01 respectively]. Findings for fructose were not significant. There was no effect of age or gender. SIBO may represent an important reversible cause of carbohydrate intolerance. It may be especially prudent to exclude SIBO patients with an early peak (≤90 minutes) in H 2 excretion. © 2017 by the Association of Clinical Scientists, Inc.

  6. False positive immunoglobulin m antibody to cytomegalovirus in child with infectious mononucleosis caused by epstein-barr virus infection.

    Science.gov (United States)

    Park, Jee Min; Shin, Jae Il; Lee, Jae Seung; Jang, Young Ho; Kim, Sung Hun; Lee, Kang Hyuk; Lee, Chang Hoon

    2009-10-31

    A 16-month-old boy was admitted because of cough that had lasted for 10 days. The patient showed severe hepatomegaly incidentally, and dual positivity of Immunoglobulin (Ig) M to Epstein-Barr virus (EBV) viral capsid antigen (VCA) and cytomegalovirus (CMV). On the basis of seroconversion to Epstein-Barr nuclear antigen (EBNA) Ig G positivity and reduced CMV Ig M titer with persistently negative CMV Ig G, a definite diagnosis of EBV-induced infectious mononucleosis was established 1 year 2 month later.

  7. Massive venlafaxine overdose resulted in a false positive Abbott AxSYM (R) urine immunoassay for phencyclidine

    NARCIS (Netherlands)

    Bond, GR; Steele, PE; Uges, DRA

    2003-01-01

    Case report: A 13-yr-old girl overdosed on 48 x 150 mg venlafaxine (Effexor XR(R)). She was taking venlafaxine regularly for depression. Her only other medications included topical Benzamycin and pyridoxine 50 mg daily for acne. The Abbott AxSYM(R) assay was positive only for phencyclidine, but

  8. Recall Latencies, Confidence, and Output Positions of True and False Memories: Implications for Recall and Metamemory Theories

    Science.gov (United States)

    Jou, Jerwen

    2008-01-01

    Recall latency, recall accuracy rate, and recall confidence were examined in free recall as a function of recall output serial position using a modified Deese-Roediger-McDermott paradigm to test a strength-based theory against the dual-retrieval process theory of recall output sequence. The strength theory predicts the item output sequence to be…

  9. Combination of RNA- and exome-sequencing efficiently eliminates false-positive somatic point mutations and indels – exemplified by cases of CN-AML

    DEFF Research Database (Denmark)

    Herborg, Laura Laine; Hansen, Marcus Celik; Roug, Anne Stidsholt

    Thorough annotation as a means of detecting highly relevant mutations, and aberrated genes, is becoming more feasible as the evidence of biological pathways underlying malignant transformation compiles. However, there is a continuous risk of misinterpretating both true and false positive observat......Thorough annotation as a means of detecting highly relevant mutations, and aberrated genes, is becoming more feasible as the evidence of biological pathways underlying malignant transformation compiles. However, there is a continuous risk of misinterpretating both true and false positive...... in the workflow, not only provides information on malignant expression profiles excluded here, but importantly help to capture the, often very few somatic mutations of myeloid leukaemia....

  10. Radiodine administration under suppression of TSH for identification of false positive receptions in patients with thyroid differentiated carcinoma (TDC): utility of the potassium perchlorate

    International Nuclear Information System (INIS)

    Santangelo, L.A.; Pitoia, F.; Sanz, C.; Niepomniszcze, H.; El Tamer, Elias

    2004-01-01

    The total body scan, after a dose of 131 I correlated with the measurement of stimulated Tg, constitute the principal pillars in follow-up of patients with TDC (thyroid differentiated carcinoma). A bibliographical search revealed more than 70 situations that can cause false total body scans positive. The examination is essential to avoid unnecessary treatment with radioiodine. The object is to evaluate the effectiveness of the radioiodine administration under hormonal therapy thyroid suppressive (THST) to eliminate the possibility of a false total body scan positive in five patients with TDC with stimulated Tg <1ng/ml

  11. [Tropheryma whipplei and Whipple disease: false positive PCR detections of Tropheryma whipplei in diagnostic samples are rare].

    Science.gov (United States)

    Le Scanff, J; Gaultier, J B; Durand, D Vital; Durieu, I; Celard, M; Benito, Y; Vandenesch, F; Rousset, H

    2008-11-01

    PCR can be used to detect T. whipplei (Tw) in samples from variable tissue types and body fluids. We report clinical, evolutive characteristics and final diagnosis in patients with positive Tw PCR assay. Retrospective study of Tw PCR realized since 10years in a microbiology laboratory. Twenty-five Tw PCR assays were positive among 200 realized. Diagnosis was not confirmed in six cases. One patient was missing for follow up. Eighteen patients presented with Whipple's disease. Among these 18 patients, 14 had a classic Whipple's disease, three patients presented an endocarditis and one patient isolated neurological manifestations. Ten patients presented fever, seven a weight loss and 12 joint involvement. Four patients presented cutaneous manifestations, only six had gastrointestinal symptoms. Neurological involvement was reported in five cases, pulmonary symptoms in four cases, cardiac involvement in six cases and ocular signs in two cases. Anemia was reported in four patients and elevated levels of acute-phase reactants in 14 cases. Positive predictive value of Tw PCR for Whipple's disease diagnosis was 75%. Thirteen patients had a good evolution with antibiotics. Three patients presented recurrence and two cases with cardiovascular involvement died. Whipple's disease is rare but often mentioned in internist experience. The diagnosis should be every time confirmed. Tw PCR assay is an important diagnostic tool but is not sufficient to establish the diagnosis and must be interpreted with histopathology and immunohistochemical testing results.

  12. FNAC AS A DIAGNOSTIC TOOL IN SALIVARY GLAND TUMOURS

    Directory of Open Access Journals (Sweden)

    Kalivarapu

    2016-03-01

    Full Text Available BACKGROUND FNAC of salivary gland tumours is an accurate, simple, rapid, inexpensive, well tolerated and harmless procedure. The success of FNAC depends on the adequacy of sample and high-quality preparation. FNAC of salivary gland neoplasms provides essential information in decision making and management. AIM OF THE STUDY Know the role of fine needle aspiration cytology in the diagnosis of benign and malignant lesions of salivary gland. MATERIAL AND METHODS This was a prospective study done at the tertiary care centre for a period of three years. A total number of 67 cases of clinically suspected salivary gland tumours were subjected to fine needle aspiration cytology and correlated with histopathology. RESULTS A total number of 67 cases, clinically suspected as salivary gland tumours were subjected to FNAC and compared with histopathology. The observations of the study were as follows: Most of the tumours were observed between the age group of 31-40 years. The commonest gland involved was the parotid gland, 56 cases of benign, 10 cases of malignant and one case of inconclusive diagnosis was made on FNAC. In the present study, FNAC showed Sensitivity of 66.6%, Specificity of 98%, Positive predictive value; 90.9%, Negative predictive value; 91%, Percentage of false negative cases 33.3%, Percentage of false positive cases 1.9% and Overall Diagnostic Accuracy of 91%. CONCLUSION FNAC is a very useful, simple, cheap, accurate and repeatable technique in the preoperative diagnosis of various salivary gland neoplasms. Overall, diagnostic accuracy was 91%, in cystic lesions of salivary glands, combined FNAC and histopathology is essential for diagnosis.

  13. Strategies to Increase Cancer Detection: Review of True-Positive and False-Negative Results at Digital Breast Tomosynthesis Screening

    Science.gov (United States)

    Weinstein, Susan P.; McDonald, Elizabeth S.; Conant, Emily F.

    2016-01-01

    Digital breast tomosynthesis (DBT) represents a valuable addition to breast cancer screening by decreasing recall rates while increasing cancer detection rates. The increased accuracy achieved with DBT is due to the quasi–three-dimensional format of the reconstructed images and the ability to “scroll through” breast tissue in the reconstructed images, thereby reducing the effect of tissue superimposition found with conventional planar digital mammography. The margins of both benign and malignant lesions are more conspicuous at DBT, which allows improved lesion characterization, increased reader confidence, and improved screening outcomes. However, even with the improvements in accuracy achieved with DBT, there remain differences in breast cancer conspicuity by mammographic view. Early data suggest that breast cancers may be more conspicuous on craniocaudal (CC) views than on mediolateral oblique (MLO) views. While some very laterally located breast cancers may be visualized on only the MLO view, the increased conspicuity of cancers on the CC view compared with the MLO view suggests that DBT screening should be performed with two-view imaging. Even with the improved conspicuity of lesions at DBT, there may still be false-negative studies. Subtle lesions seen on only one view may be discounted, and dense and/or complex tissue patterns may make some cancers occult or extremely difficult to detect. Therefore, radiologists should be cognizant of both perceptual and cognitive errors to avoid potential pitfalls in lesion detection and characterization. ©RSNA, 2016 Online supplemental material is available for this article. PMID:27715711

  14. Preoperative localization of enlarged parathyroid glands by 99mTc-MIBI scintigraphy

    International Nuclear Information System (INIS)

    Fujimoto, Nobumasa; Itoh, Kiichiro; Kishikawa, Hidehumi; Tohda, Akira; Takaha, Natsuki; Kobayashi, Yoshiyuki; Nakamori, Shigeru; Sagawa, Shiro; Sonoda, Takao

    1997-01-01

    From June 1994 to September 1996, 24 patients with biochemical confirmation of hyperparathyroidism were studied with 99m Tc-MIBI scintigraphy prior to operation. Eleven patients had primary hyperparathyroidism (PHPT) and 13 had secondary hyperparathyroidism (SHPT) associated with chronic renal failure, including one patient with recurrent disease after subtotal parathyroidectomy. A positive 99m Tc-MIBI scan for an enlarged gland was defined as an area of persistent focal uptake on the delayed image acquired at 150 min after intravenous injection of 600 MBq of 99m Tc-MIBI. Of 11 patients with PHPT, 10 were found to have solitary parathyroid adenomas at surgery and one patient had primary hyperplasia. 99m Tc-MIBI scintigraphy accurately detected 9 of 10 adenomas and 2 of 3 hyperplastic glands with no false positive results. Both of the two glands that were not detected by 99m Tc-MIBI weighted 200 mg. The mean weight of the 11 glands that were visualized was 1264 mg. The sensitivity and predictive value positive for PHPT were 84.6% and 100%, respectively. In 13 patients with SHPT, all of 49 parathyroid glands were identified during surgery, with 43 hyperplastic glands and 6 normal-size glands. Of 43 hyperplastic glands, 28 were detected by 99m Tc-MIBI and there was significant difference between the mean weight of these 28 glands and that of the 15 nonimaged hyperplastic glands. None of the six normal glands were imaged with 99m Tc-MIBI. One patient had a false positive scan caused by a thyroid nodule. The sensitivity and predictive value positive for SHPT were 65.1% and 96.6%, respectively. (K.H.)

  15. ABIOTIC O2 LEVELS ON PLANETS AROUND F, G, K, AND M STARS: POSSIBLE FALSE POSITIVES FOR LIFE?

    International Nuclear Information System (INIS)

    Harman, C. E.; Kasting, J. F.; Schwieterman, E. W.; Schottelkotte, J. C.

    2015-01-01

    In the search for life on Earth-like planets around other stars, the first (and likely only) information will come from the spectroscopic characterization of the planet's atmosphere. Of the countless number of chemical species terrestrial life produces, only a few have the distinct spectral features and the necessary atmospheric abundance to be detectable. The easiest of these species to observe in Earth's atmosphere is O 2 (and its photochemical byproduct, O 3 ). However, O 2 can also be produced abiotically by photolysis of CO 2 , followed by recombination of O atoms with each other. CO is produced in stoichiometric proportions. Whether O 2 and CO can accumulate to appreciable concentrations depends on the ratio of far-ultraviolet (FUV) to near-ultraviolet (NUV) radiation coming from the planet's parent star and on what happens to these gases when they dissolve in a planet's oceans. Using a one-dimensional photochemical model, we demonstrate that O 2 derived from CO 2 photolysis should not accumulate to measurable concentrations on planets around F- and G-type stars. K-star, and especially M-star planets, however, may build up O 2 because of the low NUV flux from their parent stars, in agreement with some previous studies. On such planets, a “false positive” for life is possible if recombination of dissolved CO and O 2 in the oceans is slow and if other O 2 sinks (e.g., reduced volcanic gases or dissolved ferrous iron) are small. O 3 , on the other hand, could be detectable at UV wavelengths (λ < 300 nm) for a much broader range of boundary conditions and stellar types

  16. ABIOTIC O{sub 2} LEVELS ON PLANETS AROUND F, G, K, AND M STARS: POSSIBLE FALSE POSITIVES FOR LIFE?

    Energy Technology Data Exchange (ETDEWEB)

    Harman, C. E.; Kasting, J. F. [Geosciences Department, Pennsylvania State University, University Park, PA 16802 (United States); Schwieterman, E. W. [NASA Astrobiology Institute—Virtual Planetary Laboratory (United States); Schottelkotte, J. C., E-mail: ceharmanjr@psu.edu [Astronomy Department, Pennsylvania State University, University Park, PA 16802 (United States)

    2015-10-20

    In the search for life on Earth-like planets around other stars, the first (and likely only) information will come from the spectroscopic characterization of the planet's atmosphere. Of the countless number of chemical species terrestrial life produces, only a few have the distinct spectral features and the necessary atmospheric abundance to be detectable. The easiest of these species to observe in Earth's atmosphere is O{sub 2} (and its photochemical byproduct, O{sub 3}). However, O{sub 2} can also be produced abiotically by photolysis of CO{sub 2}, followed by recombination of O atoms with each other. CO is produced in stoichiometric proportions. Whether O{sub 2} and CO can accumulate to appreciable concentrations depends on the ratio of far-ultraviolet (FUV) to near-ultraviolet (NUV) radiation coming from the planet's parent star and on what happens to these gases when they dissolve in a planet's oceans. Using a one-dimensional photochemical model, we demonstrate that O{sub 2} derived from CO{sub 2} photolysis should not accumulate to measurable concentrations on planets around F- and G-type stars. K-star, and especially M-star planets, however, may build up O{sub 2} because of the low NUV flux from their parent stars, in agreement with some previous studies. On such planets, a “false positive” for life is possible if recombination of dissolved CO and O{sub 2} in the oceans is slow and if other O{sub 2} sinks (e.g., reduced volcanic gases or dissolved ferrous iron) are small. O{sub 3}, on the other hand, could be detectable at UV wavelengths (λ < 300 nm) for a much broader range of boundary conditions and stellar types.

  17. Myositis ossificans: a false positive of malignancy in PET - CT F.D.G. and in osseous scintigraphy with HMDP 99Tc

    International Nuclear Information System (INIS)

    Hassler, S.; Bourahla, K.

    2010-01-01

    Myositis ossificans is a difficult differential diagnosis and a false positive for malignancy in both 99m Tc H.M.D.P. (hydroxy-methylene diphosphonate) scintigraphy and in exploration PET-F.D.G. This hypothesis should be mentioned in case of young patients, despite the unusual scintigraphic appearance in a benign process. (N.C.)

  18. Likelihood of early detection of breast cancer in relation to false-positive risk in life-time mammographic screening: population-based cohort study.

    Science.gov (United States)

    Otten, J D M; Fracheboud, J; den Heeten, G J; Otto, S J; Holland, R; de Koning, H J; Broeders, M J M; Verbeek, A L M

    2013-10-01

    Women require balanced, high-quality information when making an informed decision on screening benefits and harms before attending biennial mammographic screening. The cumulative risk of a false-positive recall and/or (small) screen-detected or interval cancer over 13 consecutive screening examinations for women aged 50 from the start of screening were estimated using data from the Nijmegen programme, the Netherlands. Women who underwent 13 successive screens in the period 1975-1976 had a 5.3% cumulative chance of a screen-detected cancer, with a 4.2% risk of at least one false-positive recall. The risk of being diagnosed with interval cancer was 3.7%. Two decades later, these estimates were 6.9%, 7.3% and 2.9%, respectively. The chance of detection of a small, favourable invasive breast cancer, anticipating a normal life-expectancy, rose from 2.3% to 3.7%. Extrapolation to digital screening mammography indicates that the proportion of false-positive results will rise to 16%. Dutch women about to participate in the screening programme can be reassured that the chance of false-positive recall in the Netherlands is relatively low. A new screening policy and improved mammography have increased the detection of an early screening carcinoma and lowering the risk of interval carcinoma.

  19. Endocrine glands

    Science.gov (United States)

    ... Diabetes Gigantism Diabetes insipidus Cushing Disease Watch this video about: Pituitary gland Testes and ovaries: Lack of sex development (unclear genitalia) Thyroid: Congenital hypothyroidism Myxedema Goiter ...

  20. Placing symptoms in context: the role of contextual criteria in reducing false positives in Diagnostic and Statistical Manual of Mental Disorders diagnoses.

    Science.gov (United States)

    Wakefield, Jerome C; First, Michael B

    2012-02-01

    The Diagnostic and Statistical Manual of Mental Disorders (DSM) definition of mental disorder requires that symptoms be caused by a dysfunction in the individual; when dysfunction is absent, symptoms represent normal-range distress or eccentricity and, if diagnosed as a mental disorder, are false positives. We hypothesized that because of psychiatry's lack of direct laboratory tests to distinguish dysfunction from normal-range distress, the context in which symptoms occur (eg, lack of imminent danger in a panic attack) is often essential to determining whether symptoms are caused by a dysfunction. If this is right, then the DSM diagnostic criteria should include many contextual criteria added to symptom syndromes to prevent dysfunction false positives. Despite their potential importance, such contextual criteria have not been previously reviewed. We, thus, systematically reviewed DSM categories to establish the extent of such uses of contextual criteria and created a typology of such uses. Of 111 sampled categories, 68 (61%) used context to prevent dysfunction false positives. Contextual criteria fell into 7 types: (1) exclusion of specific false-positive scenarios; (2) requiring that patients experience preconditions for normal responses (eg, requiring that individuals experience adequate sexual stimulation before being diagnosed with sexual dysfunctions); (3) requiring that symptoms be disproportionate relative to circumstances; (4) for childhood disorders, requiring that symptoms be developmentally inappropriate; (5) requiring that symptoms occur in multiple contexts; (6) requiring a substantial discrepancy between beliefs and reality; and (7) a residual category. Most DSM categories include contextual criteria to eliminate false-positive diagnoses and increase validity of descriptive criteria. Future revisions should systematically evaluate each category's need for contextual criteria. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. [EXPERIENCE OF STUDY AND POSSIBLE WAYS OF ELIMINATION OF FALSE POSITIVE AND FALSE NEGATIVE RESULTS DURING EXECUTION OF POLYMERASE CHAIN REACTION ON AN EXAMPLE OF JUNIN VIRUS RNA DETECTION].

    Science.gov (United States)

    Sizikova, T E; Lebedev, V N; Pantyukhov, V B; Borisevich, S V; Merkulov, V A

    2015-01-01

    Experience of study and possible ways of elimination of false positive and false negative results during execution of polymerase chain reaction on an example of Junin virus RNA detection. MATERIALSS AND METHODS: Junin virus--causative agent of Argentine hemorrhagic fever (AHF) strain XJpR37/5787 was obtained from the State collection of pathogenicity group I causative agents of the 48th Central Research Institute. Reagent kit for detection of Junin virus RNA by RT-PCR was developed in the Institute and consists of 4 sets: for isolation of RNA, execution of reverse-transcription reaction, execution of PCR and electrophoretic detection of PCR products. RT-PCR was carried out by a standard technique. Continuous cell cultures of African green monkey Vero B, GMK-AH-1(D) were obtained from the museum of cell culture department of the Centre. An experimental study of the effect of various factors of impact on the sample under investigation ("thawing-freezing", presence of formaldehyde, heparin) on the obtaining of false negative results during Junin virus RNA detection by using RT-PCR was studied. Addition of 0.01% heparin to the samples was shown to completely inhibit PCR. Addition of 0.05% formaldehyde significantly reduces sensitivity of the method. A possibility of reduction of analysis timeframe from 15 to 5 days was shown during detection of the causative agent in samples with low concentration of the latter by growing the samples and subsequent analysis of the material obtained by using RT-PCR. During detection of causative agent by using RT-PCR false negative results could appear in the presence of formaldehyde and heparin in the sample. A possibility of elimination of false negative PCR results due to concentration of the causative agent in the sample under investigation at a level below sensitivity threshold was shown on the example of Junin virus RNA detection by using growing of the pathogen in appropriate accumulation system with subsequent analysis of the

  2. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  3. High prevalence of human anti-bovine IgG antibodies as the major cause of false positive reactions in two-site immunoassays based on monoclonal antibodies

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Koch, Claus; Jensen, Charlotte H

    2004-01-01

    were purified by protein G affinity chromatography from culture supernatant containing 10% (v/v) fetal calf serum (FCS). Human anti-animal IgG (bovine, mouse, horse, and swine) antibodies and human anti-bovine serum albumin antibodies were measured using an ELISA design, with direct bridging...... of the solid phase and biotinylated antigens. The false positive reactions were abolished by addition of 1% (v/v) bovine serum to the dilution buffer (DB). Human anti-bovine IgG antibodies (HABIA) were detected in 99 out of 104 sera from blood donors (50 females; 54 males). HABIA levels in male sera (n = 54......) were positively correlated to the false positive signals in the PP14 ELISA (r = 0.923; p detected in the donor sera, but levels and frequencies were lower compared to that of HABIA. Furthermore, HABIA were...

  4. Efficient detection of human circulating tumor cells without significant production of false-positive cells by a novel conditionally replicating adenovirus

    Directory of Open Access Journals (Sweden)

    Fuminori Sakurai

    2016-01-01

    Full Text Available Circulating tumor cells (CTCs are promising biomarkers in several cancers, and thus methods and apparatuses for their detection and quantification in the blood have been actively pursued. A novel CTC detection system using a green fluorescence protein (GFP–expressing conditionally replicating adenovirus (Ad (rAd-GFP was recently developed; however, there is concern about the production of false-positive cells (GFP-positive normal blood cells when using rAd-GFP, particularly at high titers. In addition, CTCs lacking or expressing low levels of coxsackievirus–adenovirus receptor (CAR cannot be detected by rAd-GFP, because rAd-GFP is constructed based on Ad serotype 5, which recognizes CAR. In order to suppress the production of false-positive cells, sequences perfectly complementary to blood cell–specific microRNA, miR-142-3p, were incorporated into the 3′-untranslated region of the E1B and GFP genes. In addition, the fiber protein was replaced with that of Ad serotype 35, which recognizes human CD46, creating rAdF35-142T-GFP. rAdF35-142T-GFP efficiently labeled not only CAR-positive tumor cells but also CAR-negative tumor cells with GFP. The numbers of false-positive cells were dramatically lower for rAdF35-142T-GFP than for rAd-GFP. CTCs in the blood of cancer patients were detected by rAdF35-142T-GFP with a large reduction in false-positive cells.

  5. A mode of error: Immunoglobulin binding protein (a subset of anti-citrullinated proteins can cause false positive tuberculosis test results in rheumatoid arthritis

    Directory of Open Access Journals (Sweden)

    Maria Greenwald

    2017-12-01

    Full Text Available Citrullinated Immunoglobulin Binding Protein (BiP is a newly described autoimmune target in rheumatoid arthritis (RA, one of many cyclic citrullinated peptides(CCP or ACPA. BiP is over-expressed in RA patients causing T cell expansion and increased interferon levels during incubation for the QuantiFERON-Gold tuberculosis test (QFT-G TB. The QFT-G TB has never been validated where interferon is increased by underlying disease, as for example RA.Of ACPA-positive RA patients (n = 126, we found a 13% false-positive TB test rate by QFT-G TB. Despite subsequent biologic therapy for 3 years of all 126 RA patients, none showed evidence of TB without INH. Most of the false-positive RA patients after treatment with biologic therapy reverted to a negative QFT-G test. False TB tests correlated with ACPA level (p < 0.02.Three healthy women without arthritis or TB exposure had negative QFT-G TB. In vitro, all three tested positive every time for TB correlating to the dose of BiP or anti-BiP added, at 2 ug/ml, 5 ug/ml, 10 ug/ml, and 20 ug/ml.BiP naturally found in the majority of ACPA-positive RA patients can result in a false positive QFT-G TB. Subsequent undertreatment of RA, if biologic therapy is withheld, and overtreatment of presumed latent TB may harm patients. Keywords: Tuberculosis, IGRA, Rheumatoid arthritis, Interferon, Anti-citrullinated peptide antibody (ACPA, Immunoglobulin binding protein (BiP

  6. The Lifetime Economic Burden of Inaccurate HER2 Testing: Estimating the Costs of False-Positive and False-Negative HER2 Test Results in US Patients with Early-Stage Breast Cancer.

    Science.gov (United States)

    Garrison, Louis P; Babigumira, Joseph B; Masaquel, Anthony; Wang, Bruce C M; Lalla, Deepa; Brammer, Melissa

    2015-06-01

    Patients with breast cancer whose tumors test positive for human epidermal growth factor receptor 2 (HER2) are treated with HER2-targeted therapies such as trastuzumab, but limitations with HER2 testing may lead to false-positive (FP) or false-negative (FN) results. To develop a US-level model to estimate the effect of tumor misclassification on health care costs and patient quality-adjusted life-years (QALYs). Decision analysis was used to estimate the number of patients with early-stage breast cancer (EBC) whose HER2 status was misclassified in 2012. FP results were assumed to generate unnecessary trastuzumab costs and unnecessary cases of trastuzumab-related cardiotoxicity. FN results were assumed to save money on trastuzumab, but with a loss of QALYs and greater risk of disease recurrence and its associated costs. QALYs were valued at $100,000 under a net monetary benefit approach. Among 226,870 women diagnosed with EBC in 2012, 3.12% (n = 7,070) and 2.18% (n = 4,955) were estimated to have had FP and FN test results, respectively. Approximately 8400 QALYs (discounted, lifetime) were lost among women not receiving trastuzumab because of FN results. The estimated incremental per-patient lifetime burden of FP or FN results was $58,900 and $116,000, respectively. The implied incremental losses to society were $417 million and $575 million, respectively. HER2 tests result in misclassification and nonoptimal treatment of approximately 12,025 US patients with EBC annually. The total economic societal loss of nearly $1 billion suggests that improvements in HER2 testing accuracy are needed and that further clinical and economic studies are warranted. Copyright © 2015 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  7. Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C.L., E-mail: clcrawf@sandia.gov; Hill, H.H.

    2013-09-17

    Graphical abstract: -- Highlights: •First study to use (−)SESI-IM-TOFMS to analyze complex mixtures of personal care products. •The study demonstrated, by identifying mobility and mass interferents with explosive signatures, which, if used separately, neither IMS nor MS alone would prevent every false positive for explosives when detected in the presence of a complex sample matrix. •Ingredients in common household cleaning products were shown to either enhance or suppress the ionization of explosives in a SESI-IM-TOFMS analysis. •Mobility separation provided real-time separation of ion species that indicated overlapping isotope peak patterns -- Abstract: Secondary electrospray ionization-ion mobility-time of flight mass spectrometry (SESI-IM-TOFMS) was used to evaluate common household products and food ingredients for any mass or mobility responses that produced false positives for explosives. These products contained ingredients which shared the same mass and mobility drift time ranges as the analyte ions for common explosives. The results of this study showed that the vast array of compounds in these products can cause either mass or mobility false positive responses. This work also found that two ingredients caused either enhanced or reduced ionization of the target analytes. Another result showed that an IMS can provide real-time separation of ion species that impede accurate mass identifications due to overlapping isotope peak patterns. The final result of this study showed that, when mass and mobility values were used to identify an ion, no false responses were found for the target explosives. The wider implication of these results is that the possibility exists for even greater occurrences of false responses from complex mixtures found in common products. Neither IMS nor MS alone can provide 100% assurance from false responses. IMS, due to its low cost, ease of operation, rugged reliability, high sensitivity and tunable selectivity, will remain

  8. False positive of the scintigraphy with octreoscan: a diagnosis of elimination; Faux positif de la scintigraphie a l'octreoscan: un diagnostic d'elimination

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, N.; Brenot-Rossi, I.; Chuto, G.; Giovannini, M.; Delpero, J.R. [Institut Paoli-Calmettes, Marseille, (France)

    2009-05-15

    The imaging of receptors with somatostatin analogs by the pentetreotide-indium 111 (octreoscan) allows the detection of endocrine tumors essentially according to the density of S.S.T.2 receptors at the tumor level. The sensitivity of octreoscan for the detection of intestine endocrine tumors is included between 80 and 100% in the different studies. The clinical case presented here enlightens a case of false positive.We concluded to a physiological elimination of pentetreotide-indium 111 with intra pancreatic biliary stasis (perhaps a dysfunction of sphincter of ampulla of bile duct) and to the lack of tumor centre. It is here a diagnosis of elimination, supported by the different results of examination. all normal. This case of false positive induced expensive and traumatic explorations for the patient. (N.C.)

  9. False-positive positron emission tomography appearance with 18F-fluorodeoxyglucose after definitive radiotherapy for cancer of the mobile tongue.

    Science.gov (United States)

    Ariji, Y; Fuwa, N; Kodaira, T; Tachibana, H; Nakamura, T; Satoh, Y; Ariji, E

    2009-01-01

    (18)F-fluorodeoxyglucose-positron emission tomography (FDG-PET) is an effective tool for evaluating the results of radiotherapy. However, some false-positive appearances caused by physiological or pathological accumulation are reported. We report on three patients who showed a high accumulation of FDG in the lingual muscles but had no recurrent tumour after definitive radiotherapy for the mobile tongue. All patients had squamous cell carcinoma of the tongue and received interstitial radiotherapy with small sources. High uptake was seen in the lingual muscles without recurrence or inflammation, based on physical and MR examinations. This false-positive appearance is thought to relate to ill-balanced high activity of the lingual muscles after definitive radiotherapy.

  10. Unusual False Positive Radioiodine Uptake on 131I Whole Body Scintigraphy in Three Unrelated Organs with Different Pathologies in Patients of Differentiated Thyroid Carcinoma: A Case Series

    International Nuclear Information System (INIS)

    Ranade, Rohit; Pawar, Shwetal; Mahajan, Abhishek; Basu, Sandip

    2016-01-01

    Three cases with unusual false positive radioiodine uptake in three different organs and pathologies (infective old fibrotic lesion in the lung, simple liver cyst, and benign breast lesion) on iodine-131 ( 131 I) whole body scintigraphy. Clinicoradiological correlation was undertaken in all three cases and the pathologies were ascertained. In all the three cases, single-photon emission computerized tomography-computed tomography (SPECT-CT) and ancillary imaging modalities were employed and were helpful in arriving at the final diagnosis

  11. Image findings of a false positive radioactive iodine-131 uptake mimicking metastasis in pulmonary aspergillosis identified on single photon emission computed tomography-computed tomography

    Directory of Open Access Journals (Sweden)

    Kamaleshwaran Koramadai Karuppusamy

    2015-01-01

    Full Text Available High doses of iodine-131 are commonly used in patients with differentiated thyroid cancer after total or subtotal thyroidectomy, in order to ablate the remaining cancer or normal thyroid tissue. Multiple different false-positive scans can occur in the absence of residual thyroid tissue or metastases. The authors present a case of abnormal uptake of radioactive iodine in the aspergilloma, potentially masquerading as pulmonary metastases.

  12. Clinical evaluation of false-positive scintigraphic lesions of the left lobe in portal hypertension. Comparison with portographic findings of the pars umbilicus of the portal vein

    Energy Technology Data Exchange (ETDEWEB)

    Takayasu, Kenichi; Moriyama, Noriyuki; Suzuki, Masao; Yamada, Tatsuya [National Cancer Center, Tokyo (Japan). Hospital; Fukutake, Toshio

    1982-09-01

    sup(99m)Tc-phytate liver scan and percutaneous transhepatic portography (PTP) were performed in 33 patients with portal hypertension due to various hepatic diseases. A defect or space occupying lesion in the left lobe on the scan in these patients was analysed with reference to portographic changes of the pars umbilicus of the left portal vein and the following results were obtained. 1) A false-positive defect on the scintigram was found in 6 (18.2%) of 33 patients, and portal vein pressure (PVP) was above 200 mmH/sub 2/O in all 6 which constituted 21.4% of 28 with PVP above 200 mmH/sub 2/O. 2) In five out of 6 patients with false-positive scan findings, the pars umbilicus was dilated to more than 25 x 15 mm in size, and it was huge and tortuous in 3 of them. 3) The mean PVP in the group with a false-positive scan tended to be higher than that in patients with no abnormalities on the scintigram. It was concluded that in reading of liver scintigrams in patients with portal hypertension, a dilated pars umbilicus and huge para-umbilical vein should be considered.

  13. Proportion of false-positive lesions at interim and end-of-treatment FDG-PET in lymphoma as determined by histology: Systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Adams, Hugo J.A., E-mail: h.j.a.adams@gmail.com; Kwee, Thomas C.

    2016-11-15

    Purpose: To systematically review and meta-analyze the proportion of false-positive lesions at interim and end-of-treatment {sup 18}F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) in lymphoma using biopsy as reference standard. Materials and methods: Medline was searched for original studies. Methodological quality of included studies was evaluated, and results were meta-analytically summarized using random effects (in case of interstudy heterogeneity [I{sup 2} ≤ 50%]) or fixed effects (in case of no interstudy heterogeneity [I{sup 2} > 50%]). Results: Eleven studies, comprising 139 patients who underwent biopsy of an FDG-avid lesion during or after completion of antilymphoma treatment, were included. Overall methodological quality was moderate. The proportion of false-positive results among all biopsied FDG-avid lesions at PET performed during of after completion of treatment ranged between 7.7% and 90.5% (the vast majority was due to inflammatory changes), with a weighted summary proportion (random effects, I{sup 2} = 75.7%) of 55.7% (95% confidence interval [CI]: 32.6–76.6%). There were no available studies on interim FDG-PET in Hodgkin lymphoma. The pooled summary false-positive proportions were 83.0% (95% CI: 72.0%–90.2%) for interim FDG-PET in non-Hodgkin lymphoma (fixed effects, I{sup 2} = 27.7%), 23.1% (95% CI: 4.7%–64.5%) for end-of-treatment FDG-PET in Hodgkin lymphoma (random effects; I{sup 2} = 67.1%), and 31.5% (95% CI: 3.9%–83.9%) for end-of-treatment FDG-PET in non-Hodgkin lymphoma (random effects, I{sup 2} = 68.3%). Conclusion: Both interim and end-of-treatment FDG-PET scans in patients with lymphoma suffer from a very high number of false-positive FDG-avid lesions. This finding, in combination with the previously reported high number of false-negative FGD-PET scans for residual disease detection, suggests that the role of interim and end-of-treatment FDG-PET should be reconsidered.

  14. Next-generation sequencing indicates false-positive MRD results and better predicts prognosis after SCT in patients with childhood ALL.

    Science.gov (United States)

    Kotrova, M; van der Velden, V H J; van Dongen, J J M; Formankova, R; Sedlacek, P; Brüggemann, M; Zuna, J; Stary, J; Trka, J; Fronkova, E

    2017-07-01

    Minimal residual disease (MRD) monitoring via quantitative PCR (qPCR) detection of Ag receptor gene rearrangements has been the most sensitive method for predicting prognosis and making post-transplant treatment decisions for patients with ALL. Despite the broad clinical usefulness and standardization of this method, we and others have repeatedly reported the possibility of false-positive MRD results caused by massive B-lymphocyte regeneration after stem cell transplantation (SCT). Next-generation sequencing (NGS) enables precise and sensitive detection of multiple Ag receptor rearrangements, thus providing a more specific readout compared to qPCR. We investigated two cohorts of children with ALL who underwent SCT (30 patients and 228 samples). The first cohort consisted of 17 patients who remained in long-term CR after SCT despite having low MRD positivity (SCT monitoring using qPCR. Only one of 27 qPCR-positive samples was confirmed to be positive by NGS. Conversely, 10 of 15 samples with low qPCR-detected MRD positivity from 13 patients who subsequently relapsed were also confirmed to be positive by NGS (P=0.002). These data show that NGS has a better specificity in post-SCT ALL management and indicate that treatment interventions aimed at reverting impending relapse should not be based on qPCR only.

  15. An audit to investigate the impact of false positive breast screening results and diagnostic work-up on re-engagement with subsequent routine screening

    International Nuclear Information System (INIS)

    Nightingale, Julie M.; Borgen, Rita; Porter-Bennett, Lisa; Szczepura, Katy

    2015-01-01

    Introduction: Women attending breast screening may have suspicious mammographic findings that are subsequently found at assessment clinic to be normal (false positive, FP). A false positive diagnosis is not harmless, with short and long term negative psychosocial consequences reported. Women are at increased relative risk of breast cancer therefore their attendance at subsequent screening is essential. Aims: To assess the impact of FP breast screening diagnosis and diagnostic work-up on re-attendance rates across four consecutive screening rounds at a typical breast screening centre. Method: Diagnostic interventions and screening re-attendance rates at one prior and two consecutive rounds were analysed for women receiving an FP diagnosis between 2004 and 2006. Results: 397 women (5.57%) were referred for further assessment, including 228 (57.43%) false positives. 34 eligible women failed to re-attend routine screening (+3 years), with 17 failing to re-attend subsequently (+6 years). 70.6% (24/34) of non-attenders had attended at least two screening rounds prior to FP assessment. 75% of FP women had an imaging-only assessment with 17.5% (30/171) failing to re-attend, and 25% received a biopsy, with 7% (4/57) failing to re-attend subsequently. Conclusion: This study is unique as it follows FP women through four consecutive screening rounds. FP non-attendance rates were considerably lower compared to the general screening population, with diagnostic work-up having limited influence. FP non-attendance may appear insignificant in comparison to total screened population, but these women are at greater risk of subsequent cancer so should be actively encouraged to re-engage with the screening programme

  16. Expression of chemokine CXCL10 in dendritic-cell-like S100β-positive cells in rat anterior pituitary gland.

    Science.gov (United States)

    Horiguchi, Kotaro; Fujiwara, Ken; Higuchi, Masashi; Yoshida, Saishu; Tsukada, Takehiro; Ueharu, Hiroki; Chen, Mo; Hasegawa, Rumi; Takigami, Shu; Ohsako, Shunji; Yashiro, Takashi; Kato, Takako; Kato, Yukio

    2014-09-01

    Chemokines are mostly small secreted polypeptides whose signals are mediated by seven trans-membrane G-protein-coupled receptors. Their functions include the control of leukocytes and the intercellular mediation of cell migration, proliferation, and adhesion in several tissues. We have previously revealed that the CXC chemokine ligand 12 (CXCL12) and its receptor 4 (CXCR4) are expressed in the anterior pituitary gland, and that the CXCL12/CXCR4 axis evokes the migration and interconnection of S100β-protein-positive cells (S100β-positive cells), which do not produce classical anterior pituitary hormones. However, little is known of the cells producing the other CXCLs and CXCRs or of their characteristics in the anterior pituitary. We therefore examined whether CXCLs and CXCRs occurred in the rat anterior pituitary lobe. We used reverse transcription plus the polymerase chain reaction to analyze the expression of Cxcl and Cxcr and identified the cells that expressed Cxcl by in situ hybridization. Transcripts of Cxcl10 and its receptor (Cxcr3 and toll-like receptor 4, Tlr4) were clearly detected: cells expressing Cxcl10 and Tlr4 were identified amongst S100β-positive cells and those expressing Cxcr3 amongst adrenocorticotropic hormone (ACTH)-producing cells. We also investigated Cxcl10 expression in subpopulations of S100β-positive cells. We separated cultured S100β-positive cells into the round-type (dendritic-cell-like) and process-type (astrocyte- or epithelial-cell-like) by their adherent activity to laminin, a component of the extracellular matrix; CXCL10 was expressed only in round-type S100β-positive cells. Thus, CXCL10 produced by a subpopulation of S100β-positive cells probably exerts an autocrine/paracrine effect on S100β-positive cells and ACTH-producing cells in the anterior lobe.

  17. False-positive radioactive iodine uptake mimicking miliary lung metastases in a patient affected by papillary thyroid cancer and IgA deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Demidowich, Andrew Paul; Reynolds, James C. [National Institutes of Health, Bethesda (United States); Kundu, Amartya [Dept. of MedicineUniversity of Massachusetts Medical School, Worcester (United States); Celi, Francesco S. [Div. of Endocrinology and MetabolismVirginia Commonwealth UniversityRichmond (United States)

    2016-09-15

    A 42-year-old female with immunoglobulin A deficiency and recurrent sinopulmonary infections underwent thyroidectomy for papillary thyroid cancer (PTC). Follow-up {sup 123}I scintigraphy demonstrated diffuse pulmonary uptake, suggesting metastatic disease. However, subsequent pathologic, biochemical and radiographic testing proved that she was in fact disease free, and the initial {sup 123}I pulmonary uptake was identified as a false positive. Inflammatory conditions may rarely cause iodine uptake in non-thyroidal tissues due to local retention, organification, and/or immunologic utilization. To avoid exposing patients to unnecessary treatments, it is critical for clinicians to recognize that comorbid pulmonary conditions may mimic metastatic PTC on radioiodine scintigraphy.

  18. Massive training artificial neural network (MTANN) for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Armato, Samuel G. III; Li, Feng; Sone, Shusuke; Doi, Kunio

    2003-01-01

    In this study, we investigated a pattern-recognition technique based on an artificial neural network (ANN), which is called a massive training artificial neural network (MTANN), for reduction of false positives in computerized detection of lung nodules in low-dose computed tomography (CT) images. The MTANN consists of a modified multilayer ANN, which is capable of operating on image data directly. The MTANN is trained by use of a large number of subregions extracted from input images together with the teacher images containing the distribution for the 'likelihood of being a nodule'. The output image is obtained by scanning an input image with the MTANN. The distinction between a nodule and a non-nodule is made by use of a score which is defined from the output image of the trained MTANN. In order to eliminate various types of non-nodules, we extended the capability of a single MTANN, and developed a multiple MTANN (Multi-MTANN). The Multi-MTANN consists of plural MTANNs that are arranged in parallel. Each MTANN is trained by using the same nodules, but with a different type of non-nodule. Each MTANN acts as an expert for a specific type of non-nodule, e.g., five different MTANNs were trained to distinguish nodules from various-sized vessels; four other MTANNs were applied to eliminate some other opacities. The outputs of the MTANNs were combined by using the logical AND operation such that each of the trained MTANNs eliminated none of the nodules, but removed the specific type of non-nodule with which the MTANN was trained, and thus removed various types of non-nodules. The Multi-MTANN consisting of nine MTANNs was trained with 10 typical nodules and 10 non-nodules representing each of nine different non-nodule types (90 training non-nodules overall) in a training set. The trained Multi-MTANN was applied to the reduction of false positives reported by our current computerized scheme for lung nodule detection based on a database of 63 low-dose CT scans (1765

  19. Expression of Slug in S100β-protein-positive cells of postnatal developing rat anterior pituitary gland.

    Science.gov (United States)

    Horiguchi, Kotaro; Fujiwara, Ken; Tsukada, Takehiro; Yako, Hideji; Tateno, Kozue; Hasegawa, Rumi; Takigami, Shu; Ohsako, Shunji; Yashiro, Takashi; Kato, Takako; Kato, Yukio

    2016-02-01

    Among heterogeneous S100β-protein-positive (S100β-positive) cells, star-like cells with extended cytoplasmic processes, the so-called folliculo-stellate cells, envelop hormone-producing cells or interconnect homophilically in the anterior pituitary. S100β-positive cells are known, from immunohistochemistry, to emerge from postnatal day (P) 10 and to proliferate and migrate in the parenchyma of the anterior pituitary with growth. Recent establishment of S100β-GFP transgenic rats expressing specifically green fluorescent protein (GFP) under the control of the S100β-promoter has allowed us to observe living S100β-positive cells. In the present study, we first confirmed that living S100β-positive cells in tissue cultures of S100β-GFP rat pituitary at P5 were present prior to P10 by means of confocal laser microscopy and that they proliferated and extended their cytoplasmic processes. Second, we examined the expression of the Snail-family zinc-finger transcription factors, Snail and Slug, to investigate the mechanism behind the morphological changes and the proliferation of S100β-positive cells. Interestingly, we detected Slug expression in S100β-positive cells and its increase together with development in the anterior pituitary. To analyze downstream of SLUG in S100β-positive cells, we utilized specific small interfering RNA for Slug mRNAs and observed that the expression of matrix metalloprotease (Mmp) 9, Mmp14 and chemokine Cxcl12 was down-regulated and that morphological changes and proliferation were decreased. Thus, our findings suggest that S100β-positive cells express Slug and that its expression is important for subsequent migration and proliferation.

  20. A Nested PCR Assay to Avoid False Positive Detection of the Microsporidian Enterocytozoon hepatopenaei (EHP) in Environmental Samples in Shrimp Farms

    Science.gov (United States)

    Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A. P.; Stentiford, Grant D.; Flegel, Timothy W.; Sritunyalucksana, Kallaya

    2016-01-01

    Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers. PMID:27832178

  1. Significance of FDG-PET in Identification of Diseases of the Appendix – Based on Experience of Two Cases Falsely Positive for FDG Accumulation

    Directory of Open Access Journals (Sweden)

    Shimpei Ogawa

    2009-04-01

    Full Text Available A discussion of the significance of F-fluorodeoxyglucose positron emission tomography (FDG-PET in the identification of diseases of the appendix is presented based on two cases falsely positive for FDG accumulation. Both cases were palpable for a tumor in the lower right abdominal region and a prominently enlarged appendix was depicted by CT. Although the patients underwent ileocecal resection based on a strong suspicion of appendiceal cancer rather than appendicitis since abnormal accumulation exhibiting maximum standard uptake values (SUVs of 7.27 and 17.11, respectively, was observed at the same site in FDG-PET examination and since there no malignant findings observed histologically, the patients were diagnosed with appendicitis. Although FDG specifically accumulates not only in malignant tumors, but also in diseases such as acute or chronic inflammation, abscesses and lymphadenitis, and identification based on SUVs has been reported to be used as a method of identification, the two cases reported here were both false-positive cases exhibiting high maximum SUVs. At the present time, although the significance of FDG-PET in the identification of diseases of the appendix is somewhat low and there are limitations on its application, various research is currently being conducted with the aim of improving diagnostic accuracy, and it is hoped that additional studies will be conducted in the future.

  2. A Nested PCR Assay to Avoid False Positive Detection of the Microsporidian Enterocytozoon hepatopenaei (EHP) in Environmental Samples in Shrimp Farms.

    Science.gov (United States)

    Jaroenlak, Pattana; Sanguanrut, Piyachat; Williams, Bryony A P; Stentiford, Grant D; Flegel, Timothy W; Sritunyalucksana, Kallaya; Itsathitphaisarn, Ornchuma

    2016-01-01

    Hepatopancreatic microsporidiosis (HPM) caused by Enterocytozoon hepatopenaei (EHP) is an important disease of cultivated shrimp. Heavy infections may lead to retarded growth and unprofitable harvests. Existing PCR detection methods target the EHP small subunit ribosomal RNA (SSU rRNA) gene (SSU-PCR). However, we discovered that they can give false positive test results due to cross reactivity of the SSU-PCR primers with DNA from closely related microsporidia that infect other aquatic organisms. This is problematic for investigating and monitoring EHP infection pathways. To overcome this problem, a sensitive and specific nested PCR method was developed for detection of the spore wall protein (SWP) gene of EHP (SWP-PCR). The new SWP-PCR method did not produce false positive results from closely related microsporidia. The first PCR step of the SWP-PCR method was 100 times (104 plasmid copies per reaction vial) more sensitive than that of the existing SSU-PCR method (106 copies) but sensitivity was equal for both in the nested step (10 copies). Since the hepatopancreas of cultivated shrimp is not currently known to be infected with microsporidia other than EHP, the SSU-PCR methods are still valid for analyzing hepatopancreatic samples despite the lower sensitivity than the SWP-PCR method. However, due to its greater specificity and sensitivity, we recommend that the SWP-PCR method be used to screen for EHP in feces, feed and environmental samples for potential EHP carriers.

  3. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  4. The Relations Between False Positive and Negative Screens and Smoking Cessation and Relapse in the National Lung Screening Trial: Implications for Public Health.

    Science.gov (United States)

    Clark, Melissa A; Gorelick, Jeremy J; Sicks, JoRean D; Park, Elyse R; Graham, Amanda L; Abrams, David B; Gareen, Ilana F

    2016-01-01

    Lung screening is an opportunity for smoking cessation and relapse prevention, but smoking behaviors may differ across screening results. Changes in smoking were evaluated among 18 840 current and former smokers aged 55-74 scheduled to receive three annual lung screenings. Participants were randomized to low-dose computed tomography or single-view chest radiography in the American College of Radiology/National Lung Screening Trial. Outcome measures included point and sustained (6-month) abstinence and motivation to quit among smokers; and relapse among smokers who quit during follow-up, recent quitters (quit < 6 months), and long-term former smokers (quit ≥ 6 months). During five years of follow-up, annual point prevalence quit rates ranged from 11.6%-13.4%; 48% of current smokers reported a quit attempt and 7% of long-term former smokers relapsed. Any false positive screening result was associated with subsequent increased point (multivariable hazard ratio HR = 1.23, 95% CI = 1.13, 1.35) and sustained (HR = 1.28, 95% CI = 1.15, 1.43) abstinence among smokers. Recent quitters with ≥1 false positive screen were less likely to relapse (HR = 0.72, 95% CI = 0.54, 0.96). Screening result was not associated with relapse among long-term former smokers or among baseline smokers who quit during follow-up. A false positive screen was associated with increased smoking cessation and less relapse among recent quitters. Consistently negative screens were not associated with greater relapse among long-term former smokers. Given the Affordable Care Act requires most health plans to cover smoking cessation and lung screening, the impact and cost-effectiveness of lung screening could be further enhanced with the addition of smoking cessation interventions. © The Author 2015. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. Detection of Yersinia enterocolitica serotype O:9 in the faeces of cattle with false positive reactions in serological tests for brucellosis in Ireland.

    Science.gov (United States)

    O'Grady, Don; Kenny, Kevin; Power, Seamus; Egan, John; Ryan, Fergus

    2016-10-01

    Intestinal infection by Yersinia enterocolitica serotype O:9 (YeO9) in cattle has been linked to false positive serological reactivity (FPSR) in diagnostic tests for brucellosis. Although eradicated in Ireland, brucellosis monitoring still identifies seropositive animals, usually one or two (termed singletons) per herd, which are classed as FPSR. To investigate a link between FPSR and YeO9, faeces and blood were collected from singleton FPSR cattle, and from companion animals, in eight selected herds with more than one FPSR animal, for YeO9 culture and Brucella serology. YeO9 was isolated from 76/474 (16%) FPSR singletons in 309 herds, but not from any of 621 animals in 122 control non-FPSR herds. In the FPSR herds 52/187 (27.8%) animals were culture positive, and 17% of the isolates were from seronegative animals. Seropositive animals were more likely to have a rising antibody titre when culture positive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. False assumptions.

    Science.gov (United States)

    Swaminathan, M

    1997-01-01

    Indian women do not have to be told the benefits of breast feeding or "rescued from the clutches of wicked multinational companies" by international agencies. There is no proof that breast feeding has declined in India; in fact, a 1987 survey revealed that 98% of Indian women breast feed. Efforts to promote breast feeding among the middle classes rely on such initiatives as the "baby friendly" hospital where breast feeding is promoted immediately after birth. This ignores the 76% of Indian women who give birth at home. Blaming this unproved decline in breast feeding on multinational companies distracts attention from more far-reaching and intractable effects of social change. While the Infant Milk Substitutes Act is helpful, it also deflects attention from more pressing issues. Another false assumption is that Indian women are abandoning breast feeding to comply with the demands of employment, but research indicates that most women give up employment for breast feeding, despite the economic cost to their families. Women also seek work in the informal sector to secure the flexibility to meet their child care responsibilities. Instead of being concerned about "teaching" women what they already know about the benefits of breast feeding, efforts should be made to remove the constraints women face as a result of their multiple roles and to empower them with the support of families, governmental policies and legislation, employers, health professionals, and the media.

  7. False-positive 18F-fluorodeoxyglucose positron emission tomography/computed tomography in a patient with metallic implants following chondrosarcoma resection.

    Science.gov (United States)

    Zhou, P U; Tang, Jinliang; Zhang, Dong; Li, Guanghui

    2016-05-01

    Positron emission tomography (PET) with fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG) has been used for the staging and evaluation of recurrence in cancer patients. We herein report a false-positive result of 18 F-FDG PET/computed tomography (CT) scan in a patient following chondrosarcoma resection and metallic implanting. A 35-year-old male patient with chondrosarcoma of the left iliac bone underwent radical resection, metal brace implanting and radiotherapy. A high uptake of 18 F-FDG was observed in the metallic implants and adjacent tissue during PET/CT scanning in the 5th year of follow-up. Tissue biopsy and follow-up examination identified no tumor recurrence or infection at these sites, suggesting that the results of 18 F-FDG PET/CT must be interpreted with caution in cancer patients with metallic implants.

  8. The Dutch Brucella abortus monitoring programme for cattle: the impact of false-positive serological reactions and comparison of serological tests.

    Science.gov (United States)

    Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G

    2002-02-01

    The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.

  9. Upward creep of the heart: A frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT

    International Nuclear Information System (INIS)

    Friedman, J.; Van Train, K.; Maddahi, J.; Rozanski, A.; Prigent, F.; Bietendorf, J.; Waxman, A.; Berman, D.S.

    1989-01-01

    A new cause of artifactual 201 Tl defects on single photon emission computed tomography (SPECT) termed upward creep of the heart is described. In 102 consecutive patients undergoing 201 Tl SPECT, 30 (29%) demonstrated upward creep defined by an upward movement of the heart of greater than or equal to 2 pixels during acquisition. In 45 consecutive patients with a less than 5% likelihood of coronary artery disease, 17 (38%) had upward creep. Of these nine had reversible 201 Tl defects localized to the inferior and basal inferoseptal walls, while none of the 28 without upward creep had defects. The 17 low likelihood patients with upward creep had longer exercise duration and higher peak heart rate than those without upward creep. In five additional low likelihood patients with upward creep in whom imaging was immediately repeated, the upward creep pattern disappeared on the repeated images. After we changed our test protocol to begin imaging 15 min postexercise, only five (14%) of 36 low likelihood patients tested demonstrated upward creep. Upward creep is probably related to a transient increase in mean total lung volume early following exhaustive exercise, resulting in a mean lower position of the diaphragm (and thus the heart) at the beginning of imaging. The frequency of this source of false-positive 201 Tl studies can be reduced by delaying SPECT acquisition until 15 min postexercise

  10. Avian metapneumovirus RT-nested-PCR: a novel false positive reducing inactivated control virus with potential applications to other RNA viruses and real time methods.

    Science.gov (United States)

    Falchieri, Marco; Brown, Paul A; Catelli, Elena; Naylor, Clive J

    2012-12-01

    Using reverse genetics, an avian metapneumovirus (AMPV) was modified for use as a positive control for validating all stages of a popular established RT-nested PCR, used in the detection of the two major AMPV subtypes (A and B). Resultant amplicons were of increased size and clearly distinguishable from those arising from unmodified virus, thus allowing false positive bands, due to control virus contamination of test samples, to be identified readily. Absorption of the control virus onto filter paper and subsequent microwave irradiation removed all infectivity while its function as an efficient RT-nested-PCR template was unaffected. Identical amplicons were produced after storage for one year. The modified virus is likely to have application as an internal standard as well as in real time methods. Additions to AMPV of RNA from other RNA viruses, including hazardous examples such HIV and influenza, are likely to yield similar safe RT-PCR controls. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. False-negative type-specific glycoprotein G antibody responses in STI clinic patients with recurrent HSV-1 or HSV-2 DNA positive genital herpes, The Netherlands.

    Science.gov (United States)

    van Rooijen, Martijn S; Roest, Wim; Hansen, Gino; Kwa, David; de Vries, Henry J C

    2016-06-01

    Herpes simplex virus (HSV) type-discriminating antibody tests (glycoprotein G (gG) directed) are used to identify naïve persons and differentiate acute infections from recurrences. We studied test characteristics of three commercially available antibody tests in patients with recurrent (established by viral PCR tests) herpes simplex virus type 1 (HSV-1) or herpes simplex virus type 2 (HSV-2) genital herpes episodes. Serum samples (at minimum 3 months after t=0) were examined for the presence of gG-1-specific or gG-2-specific antibodies using the HerpeSelect 1 and 2 Immunoblot IgG, the HerpeSelect 1 and 2 enzyme linked immunoassays IgG and the LIAISON HSV-1 and HSV-2 IgG indirect chemiluminescence immunoassays. The immunoblot was HSV-1 positive in 70.6% (95% CI 44.0% to 89.7%), the LIAISON in 88.2% (95% CI 63.5% to 98.5%) and the ELISA in 82.4% (95% CI 56.6% to 96.2%) of the 17 patients with a recurrent HSV-1 episode. From 33 patients with a recurrent HSV-2 episode, the immunoblot was HSV-2 positive in 84.8% (95% CI 68.1% to 94.9%), the LIAISON in 69.7% (95% CI 51.3% to 84.4%) and the ELISA in 84.8% (95% CI 68.1% to 94.9%). Among 15/17 (88.2%; 95% CI 63.5% to 98.5%) patients with HSV-1 and 30/33 (90.1%; 95% CI 75.7% to 98.1%) patients with HSV-2, HSV-1 or HSV-2 antibodies, respectively, were detected in at least one of the three antibody tests. Commercial type-specific gG HSV-1 or HSV-2 antibody assays were false negative in 12-30% of patients with recurrent HSV-1 or HSV-2 DNA positive genital lesions. The clinical and epidemiological use of type-specific HSV serology can be hampered by false-negative results, especially if based on a single test. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Massive-training artificial neural network (MTANN) for reduction of false positives in computer-aided detection of polyps: Suppression of rectal tubes

    International Nuclear Information System (INIS)

    Suzuki, Kenji; Yoshida, Hiroyuki; Naeppi, Janne; Dachman, Abraham H.

    2006-01-01

    One of the limitations of the current computer-aided detection (CAD) of polyps in CT colonography (CTC) is a relatively large number of false-positive (FP) detections. Rectal tubes (RTs) are one of the typical sources of FPs because a portion of a RT, especially a portion of a bulbous tip, often exhibits a cap-like shape that closely mimics the appearance of a small polyp. Radiologists can easily recognize and dismiss RT-induced FPs; thus, they may lose their confidence in CAD as an effective tool if the CAD scheme generates such ''obvious'' FPs due to RTs consistently. In addition, RT-induced FPs may distract radiologists from less common true positives in the rectum. Therefore, removal RT-induced FPs as well as other types of FPs is desirable while maintaining a high sensitivity in the detection of polyps. We developed a three-dimensional (3D) massive-training artificial neural network (MTANN) for distinction between polyps and RTs in 3D CTC volumetric data. The 3D MTANN is a supervised volume-processing technique which is trained with input CTC volumes and the corresponding ''teaching'' volumes. The teaching volume for a polyp contains a 3D Gaussian distribution, and that for a RT contains zeros for enhancement of polyps and suppression of RTs, respectively. For distinction between polyps and nonpolyps including RTs, a 3D scoring method based on a 3D Gaussian weighting function is applied to the output of the trained 3D MTANN. Our database consisted of CTC examinations of 73 patients, scanned in both supine and prone positions (146 CTC data sets in total), with optical colonoscopy as a reference standard for the presence of polyps. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. These CTC cases were subjected to our previously reported CAD scheme that included centerline-based segmentation of the colon, shape-based detection of polyps, and reduction of FPs by use of a Bayesian neural network based on geometric and texture

  13. Toward the breast screening balance sheet: cumulative risk of false positives for annual versus biennial mammograms commencing at age 40 or 50.

    Science.gov (United States)

    Winch, Caleb J; Sherman, Kerry A; Boyages, John

    2015-01-01

    This study aimed to: (1) Estimate cumulative risk of recall from breast screening where no cancer is detected (a harm) in Australia; (2) Compare women screened annually versus biennially, commencing age 40 versus 50; and (3) Compare with international findings. At the no-cost metropolitan program studied, women attended biennial screening, but were offered annual screening if regarded at elevated risk for breast cancer. The cumulative risk of at least one recall was estimated using discrete-time survival analysis. Cancer detection statistics were computed. In total, 801,636 mammograms were undertaken in 231,824 women. Over 10 years, cumulative risk of recall was 13.3 % (95 % CI 12.7-13.8) for those screened biennially, and 19.9 % (CI 16.6-23.2) for those screened annually from age 50-51. Cumulative risk of complex false positive involving a biopsy was 3.1 % (CI 2.9-3.4) and 5.0 % (CI 3.4-6.6), respectively. From age 40-41, the risk of recall was 15.1 % (CI 14.3-16.0) and 22.5 % (CI 17.9-27.1) for biennial and annual screening, respectively. Corresponding rates of complex false positive were 3.3 % (CI 2.9-3.8) and 6.3 % (CI 3.4-9.1). Over 10 mammograms, invasive cancer was detected in 3.4 % (CI 3.3-3.5) and ductal carcinoma in situ in 0.7 % (CI 0.6-0.7) of women, with a non-significant trend toward a larger proportion of Tis and T1N0 cancers in women screened annually (74.5 %) versus biennially (70.1 %), χ (2) = 2.77, p = 0.10. Cancer detection was comparable to international findings. Recall risk was equal to European estimates for women screening from 50 and lower for screening from 40. Recall risk was half of United States' rates across start age and rescreening interval categories. Future benefit/harm balance sheets may be useful for communicating these findings to women.

  14. Characteristics of primary Sjögren's syndrome patients with IgG4 positive plasma cells infiltration in the labial salivary glands.

    Science.gov (United States)

    Liu, Chang; Zhang, Huayong; Yao, Genhong; Hu, Yunxia; Qi, Jingjing; Wang, Yan; Chen, Weiwei; Tang, Xiaojun; Li, Wenchao; Lu, Liwei; Gu, Luo; Sun, Lingyun

    2017-01-01

    The purpose of this study was to investigate the characteristics of primary Sjögren's syndrome (pSS) patients with IgG4 positive (IgG4 + ) plasma cell infiltration in labial salivary glands (LSGs). Paraffin sections of LSGs from 336 pSS patients were stained with IgG4 and IgG monoclonal antibodies. According to the infiltration of IgG4 + plasma cells, patients were divided and clinical and serological characteristics were analyzed and compared. Based on the infiltration of IgG4 + plasma cells in the LSGs, patients were divided into three subgroups, low IgG4, moderate IgG4, and high IgG4 groups. A negative association between the number of infiltrated IgG4 + plasma cells and the disease characteristics was observed. We found that the higher the IgG4 + expression in plasma cells, the lower the positive rates of serum anti-SSA antibodies, anti-SSB antibodies, antinuclear antibodies (ANA), and rheumatoid factor (RF). Besides, patients from the high IgG4 group had the highest frequency of interstitial lung disease (ILD, 30.6%) and tubulointerstitial nephritis (TIN, 13.9%), but the lowest frequency of leucopenia (13.9%), thrombocytopenia (11.1%), and abnormal thyroidal function (0%). PSS patients with different IgG4 + plasma cells infiltration in the LSGs had distinctive clinical and laboratory characteristics. It may help us to further understand the role of IgG4 + plasma cells in pSS.

  15. Raising Awareness of False Positive Newborn Screening Results Arising from Pivalate-Containing Creams and Antibiotics in Europe When Screening for Isovaleric Acidaemia

    Directory of Open Access Journals (Sweden)

    James R. Bonham

    2018-02-01

    Full Text Available While the early and asymptomatic recognition of treatable conditions offered by newborn screening confers clear health benefits for the affected child, the clinical referral of patients with screen positive results can cause significant harm for some families. The use of pivalate-containing antibiotics and more recently the inclusion of neopentanoate as a component within moisturising creams used as nipple balms by nursing mothers can result in a significant number of false positive results when screening for isovaleric acidaemia (IVA by measuring C5 acylcarnitine. A recent survey conducted within centres from nine countries indicated that this form of contamination had been or was a significant confounding factor in the detection of IVA in seven of the nine who responded. In three of these seven the prominent cause was believed to derive from the use of moisturising creams and in another three from antibiotics containing pivalate; one country reported that the cause was mixed. As a result, four of these seven centres routinely perform second tier testing to resolve C5 isobars when an initial C5 result is elevated, and a fifth is considering making this change within their national programme. The use of creams containing neopentanoate by nursing mothers and evolving patterns in the prescription of pivalate-containing antibiotics during pregnancy require those involved in the design and operation of newborn screening programmes used to detect IVA and the doctors who receive clinical referrals from these programmes to maintain an awareness of the potential impact of this form of interference on patient results.

  16. Small intestinal bacterial overgrowth as an uncommon cause of false positive lactose hydrogen breath test among patients with diarrhea-predominant irritable bowel syndrome in Asia.

    Science.gov (United States)

    Wang, Yilin; Xiong, Lishou; Gong, Xiaorong; Li, Weimin; Zhang, Xiangsong; Chen, Minhu

    2015-06-01

    It has been reported that small intestinal bacterial overgrowth (SIBO) may lead to false positive diagnoses of lactose malabsorption (LM) in irritable bowel syndrome patients. The aim of this study was to determine the influence of SIBO on lactose hydrogen breath test (HBT) results in these patients. Diarrhea-predominant irritable bowel syndrome patients with abnormal lactose HBTs ingested a test meal containing (99m) Tc and lactose. The location of the test meal and the breath levels of hydrogen were recorded simultaneously by scintigraphic scanning and lactose HBT, respectively. The increase in hydrogen concentration was not considered to be caused by SIBO if ≥ 10% of (99m) Tc accumulated in the cecal region at the time or before of abnormal lactose HBT. LM was present in 84% (31/37) of irritable bowel syndrome patients. Twenty of these patients agreed to measurement of oro-cecal transit time. Only three patients (15%) with abnormal lactose HBT might have had SIBO. The median oro-cecal transit time between LM and lactose intolerance patients were 75 min and 45 min, respectively (Z=2.545, P=0.011). Most of irritable bowel syndrome patients with an abnormal lactose HBT had LM. SIBO had little impact on the interpretation of lactose HBTs. The patients with lactose intolerance had faster small intestinal transit than LM patients. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  17. False Positive 18F-FDG Uptake in Mediastinal Lymph Nodes Detected with Positron Emission Tomography in Breast Cancer: A Case Report

    Directory of Open Access Journals (Sweden)

    Gamze Uğurluer

    2013-01-01

    Full Text Available Breast cancer is the most frequently diagnosed cancer among females. It is accepted that lymph node involvement with metastatic tumor and the presence of distant metastasis are the most important prognostic factors. Accurate staging is important in determining prognosis and appropriate treatment. Positron emission tomography with computed tomography detects malignancies using 2-[18F]-fluoro-2-deoxy-d-glucose (18F-FDG PET CT with high accuracy and they contribute to decisions regarding diagnosis, staging, recurrence, and treatment response. Here, we report a case of false positive metastatic mediastinal lymph nodes that were diagnosed by 18F-FDG PET CT in a 40-year-old breast cancer patient who had undergone preoperative evaluation. Right paratracheal, prevascular, aorticopulmonary, precarinal, subcarinal, hilar, and subhilar multiple conglomerated mediastinal lymph nodes were revealed in addition to left breast mass and axillary lymph nodes. Mediastinoscopy was performed with biopsy and pathology was reported as granulomatous lymphadenitis. In conclusion, any abnormal FDG accumulation in unusual lymph nodes must be evaluated carefully and confirmed histopathologically.

  18. Specificity and false positive rates of the Test of Memory Malingering, Rey 15-item Test, and Rey Word Recognition Test among forensic inpatients with intellectual disabilities.

    Science.gov (United States)

    Love, Christopher M; Glassmire, David M; Zanolini, Shanna Jordan; Wolf, Amanda

    2014-10-01

    This study evaluated the specificity and false positive (FP) rates of the Rey 15-Item Test (FIT), Word Recognition Test (WRT), and Test of Memory Malingering (TOMM) in a sample of 21 forensic inpatients with mild intellectual disability (ID). The FIT demonstrated an FP rate of 23.8% with the standard quantitative cutoff score. Certain qualitative error types on the FIT showed promise and had low FP rates. The WRT obtained an FP rate of 0.0% with previously reported cutoff scores. Finally, the TOMM demonstrated low FP rates of 4.8% and 0.0% on Trial 2 and the Retention Trial, respectively, when applying the standard cutoff score. FP rates are reported for a range of cutoff scores and compared with published research on individuals diagnosed with ID. Results indicated that although the quantitative variables on the FIT had unacceptably high FP rates, the TOMM and WRT had low FP rates, increasing the confidence clinicians can place in scores reflecting poor effort on these measures during ID evaluations. © The Author(s) 2014.

  19. Interpreting the results of the Semmes-Weinstein monofilament test: accounting for false-positive answers in the international consensus on the diabetic foot protocol by a new model.

    Science.gov (United States)

    Slater, Robert A; Koren, Shlomit; Ramot, Yoram; Buchs, Andreas; Rapoport, Micha J

    2014-01-01

    The Semmes-Weinstein monofilament is the most widely used test to diagnose the loss of protective sensation. The commonly used protocol of the International Consensus on the Diabetic Foot includes a 'sham' application that allows for false-positive answers. We sought to study the heretofore unexamined significance of false-positive answers. Forty-five patients with diabetes and a history of pedal ulceration (Group I) and 81 patients with diabetes but no history of ulceration (Group II) were studied. The three original sites of the International Consensus on the Diabetic Foot at the hallux, 1st metatarsal and 5th metatarsal areas were used. At each location, the test was performed three times: 2 actual and 1 "sham" applications. Scores were graded from 0 to 3 based upon correct responses. Determination of loss of protective sensation was performed with and without calculating a false-positive answer as a minus 1 score. False-positive responses were found in a significant percentage of patients with and without history of ulceration. Introducing false-positive results as minus 1 into the test outcome significantly increased the number of patients diagnosed with loss of protective sensation in both groups. False-positive answers can significantly affect Semmes-Weinstein monofilament test results and the diagnosis of LOPS. A model that accounts for false-positive answers is offered. Copyright © 2013 John Wiley & Sons, Ltd.

  20. Physiological Levels of Pik3ca H1047R Mutation in the Mouse Mammary Gland Results in Ductal Hyperplasia and Formation of ERα-Positive Tumors

    Science.gov (United States)

    Tikoo, Anjali; Roh, Vincent; Montgomery, Karen G.; Ivetac, Ivan; Waring, Paul; Pelzer, Rebecca; Hare, Lauren; Shackleton, Mark; Humbert, Patrick; Phillips, Wayne A.

    2012-01-01

    PIK3CA, the gene coding for the p110α subunit of phosphoinositide 3-kinase, is frequently mutated in a variety of human tumors including breast cancers. To better understand the role of mutant PIK3CA in the initiation and/or progression of breast cancer, we have generated mice with a conditional knock-in of the common activating mutation, Pik3caH1047R, into one allele of the endogenous gene in the mammary gland. These mice developed a ductal anaplasia and hyperplasia by 6 weeks of age characterized by multi-layering of the epithelial lining of the mammary ducts and expansion of the luminal progenitor (Lin−; CD29lo; CD24+; CD61+) cell population. The Pik3caH1047R expressing mice eventually develop mammary tumors with 100% penetrance but with a long latency (>12 months). This is significantly longer than has been reported for transgenic models where expression of the mutant Pik3ca is driven by an exogenous promoter. Histological analysis of the tumors formed revealed predominantly ERα-positive fibroadenomas, carcinosarcomas and sarcomas. In vitro induction of Pik3caH1047R in immortalized mammary epithelial cells also resulted in tumor formation when injected into the mammary fat pad of immunodeficient recipient mice. This novel model, which reproduces the scenario of a heterozygous somatic mutation occurring in the endogenous PIK3CA gene, will thus be a valuable tool for investigating the role of Pik3caH1047R mutation in mammary tumorigenesis both in vivo and in vitro. PMID:22666336

  1. Physiological levels of Pik3ca(H1047R mutation in the mouse mammary gland results in ductal hyperplasia and formation of ERα-positive tumors.

    Directory of Open Access Journals (Sweden)

    Anjali Tikoo

    Full Text Available PIK3CA, the gene coding for the p110α subunit of phosphoinositide 3-kinase, is frequently mutated in a variety of human tumors including breast cancers. To better understand the role of mutant PIK3CA in the initiation and/or progression of breast cancer, we have generated mice with a conditional knock-in of the common activating mutation, Pik3ca(H1047R, into one allele of the endogenous gene in the mammary gland. These mice developed a ductal anaplasia and hyperplasia by 6 weeks of age characterized by multi-layering of the epithelial lining of the mammary ducts and expansion of the luminal progenitor (Lin(-; CD29(lo; CD24(+; CD61(+ cell population. The Pik3ca(H1047R expressing mice eventually develop mammary tumors with 100% penetrance but with a long latency (>12 months. This is significantly longer than has been reported for transgenic models where expression of the mutant Pik3ca is driven by an exogenous promoter. Histological analysis of the tumors formed revealed predominantly ERα-positive fibroadenomas, carcinosarcomas and sarcomas. In vitro induction of Pik3ca(H1047R in immortalized mammary epithelial cells also resulted in tumor formation when injected into the mammary fat pad of immunodeficient recipient mice. This novel model, which reproduces the scenario of a heterozygous somatic mutation occurring in the endogenous PIK3CA gene, will thus be a valuable tool for investigating the role of Pik3ca(H1047R mutation in mammary tumorigenesis both in vivo and in vitro.

  2. Contamination in the Kepler field. Identification of 685 KOIs as false positives via ephemeris matching based ON Q1-Q12 data

    Energy Technology Data Exchange (ETDEWEB)

    Coughlin, Jeffrey L.; Thompson, Susan E.; Burke, Christopher J.; Caldwell, Douglas A.; Jenkins, Jon M.; Mullally, Fergal R.; Rowe, Jason F. [SETI Institute, 189 Bernardo Avenue, Mountain View, CA 94043 (United States); Bryson, Stephen T.; Haas, Michael R.; Howell, Steve B. [NASA Ames Research Center, M/S 244-30, Moffett Field, CA 94035 (United States); Christiansen, Jessie L. [NASA Exoplanet Science Institute, California Institute of Technology, Pasadena CA 91125 (United States); Kolodziejczak, Jeffery J., E-mail: jeffrey.l.coughlin@nasa.gov [NASA Marshall Space Flight Center, Huntsville, AL 35812 (United States)

    2014-05-01

    The Kepler mission has to date found almost 6000 planetary transit-like signals, utilizing three years of data for over 170,000 stars at extremely high photometric precision. Due to its design, contamination from eclipsing binaries, variable stars, and other transiting planets results in a significant number of these signals being false positives (FPs). This directly affects the determination of the occurrence rate of Earth-like planets in our Galaxy, as well as other planet population statistics. In order to detect as many of these FPs as possible, we perform ephemeris matching among all transiting planet, eclipsing binary, and variable star sources. We find that 685 Kepler Objects of Interest (KOIs)—12% of all those analyzed—are FPs as a result of contamination, due to 409 unique parent sources. Of these, 118 have not previously been identified by other methods. We estimate that ∼35% of KOIs are FPs due to contamination, when performing a first-order correction for observational bias. Comparing single-planet candidate KOIs to multi-planet candidate KOIs, we find an observed FP fraction due to contamination of 16% and 2.4% respectively, bolstering the existing evidence that multi-planet KOIs are significantly less likely to be FPs. We also analyze the parameter distributions of the ephemeris matches and derive a simple model for the most common type of contamination in the Kepler field. We find that the ephemeris matching technique is able to identify low signal-to-noise FPs that are difficult to identify with other vetting techniques. We expect FP KOIs to become more frequent when analyzing more quarters of Kepler data, and note that many of them will not be able to be identified based on Kepler data alone.

  3. Curved planar reformation and optimal path tracing (CROP) method for false positive reduction in computer-aided detection of pulmonary embolism in CTPA

    Science.gov (United States)

    Zhou, Chuan; Chan, Heang-Ping; Guo, Yanhui; Wei, Jun; Chughtai, Aamer; Hadjiiski, Lubomir M.; Sundaram, Baskaran; Patel, Smita; Kuriakose, Jean W.; Kazerooni, Ella A.

    2013-03-01

    The curved planar reformation (CPR) method re-samples the vascular structures along the vessel centerline to generate longitudinal cross-section views. The CPR technique has been commonly used in coronary CTA workstation to facilitate radiologists' visual assessment of coronary diseases, but has not yet been used for pulmonary vessel analysis in CTPA due to the complicated tree structures and the vast network of pulmonary vasculature. In this study, a new curved planar reformation and optimal path tracing (CROP) method was developed to facilitate feature extraction and false positive (FP) reduction and improve our PE detection system. PE candidates are first identified in the segmented pulmonary vessels at prescreening. Based on Dijkstra's algorithm, the optimal path (OP) is traced from the pulmonary trunk bifurcation point to each PE candidate. The traced vessel is then straightened and a reformatted volume is generated using CPR. Eleven new features that characterize the intensity, gradient, and topology are extracted from the PE candidate in the CPR volume and combined with the previously developed 9 features to form a new feature space for FP classification. With IRB approval, CTPA of 59 PE cases were retrospectively collected from our patient files (UM set) and 69 PE cases from the PIOPED II data set with access permission. 595 and 800 PEs were manually marked by experienced radiologists as reference standard for the UM and PIOPED set, respectively. At a test sensitivity of 80%, the average FP rate was improved from 18.9 to 11.9 FPs/case with the new method for the PIOPED set when the UM set was used for training. The FP rate was improved from 22.6 to 14.2 FPs/case for the UM set when the PIOPED set was used for training. The improvement in the free response receiver operating characteristic (FROC) curves was statistically significant (p<0.05) by JAFROC analysis, indicating that the new features extracted from the CROP method are useful for FP reduction.

  4. Caprine and ovine Greek dairy products: The official German method generates false-positive results due to κ-casein gene polymorphism.

    Science.gov (United States)

    Tsartsianidou, V; Triantafillidou, D; Karaiskou, N; Tarantili, P; Triantafillidis, G; Georgakis, E; Triantafyllidis, A

    2017-05-01

    Caseins are widely used for species identification of dairy products. Isoelectric focusing (IEF) of para-κ-casein peptide is used as the official German method for the differentiation between caprine (isoform A) and ovine (isoform B) dairy products, based on their different isoelectric points. The discrimination between Greek goat and ewe dairy products using IEF has, however, been shown to be problematic because of the existence of the ewe isoform in milk from Greek indigenous dairy goats. This could be due to nucleotide polymorphisms within the goat κ-casein gene of Greek indigenous breeds, which alter the isoelectric point of the para-κ-casein peptide and lead to false positive results. Previous DNA analysis of the goat κ-casein gene has shown high levels of polymorphism; however, no such information is available for Greek indigenous dairy goats. Therefore, 87 indigenous dairy goats were sequenced at exon IV of κ-casein gene. In total, 9 polymorphic sites were detected. Three nonsynonymous point mutations were identified, which change the isoelectric point of the goat para-κ-casein peptide so that it appears identical to that of the ewe peptide. Ten composite genotypes were reconstructed and 6 of them included the problematic point mutations. For the verification of genetic results, IEF was carried out. Both goat and ewe patterns appeared in the problematic genotypes. The frequency of these genotypes could be characterized as moderate (0.23) to high (0.60) within Greek indigenous breeds. However, this is not an issue restricted to Greece, as such genotypes have been detected in various non-Greek goat breeds. In conclusion, IEF based on the official German method is certainly inappropriate for ovine and caprine discrimination concerning Greek dairy goat products, and consequently a new method should be established. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Thymus Gland Anatomy

    Science.gov (United States)

    ... historical Searches are case-insensitive Thymus Gland, Adult, Anatomy Add to My Pictures View /Download : Small: 720x576 ... Large: 3000x2400 View Download Title: Thymus Gland, Adult, Anatomy Description: Anatomy of the thymus gland; drawing shows ...

  6. Adrenal Gland Tumors: Statistics

    Science.gov (United States)

    ... Gland Tumor: Statistics Request Permissions Adrenal Gland Tumor: Statistics Approved by the Cancer.Net Editorial Board , 03/ ... primary adrenal gland tumor is very uncommon. Exact statistics are not available for this type of tumor ...

  7. Aquaporins and Gland Secretion.

    Science.gov (United States)

    Delporte, Christine

    2017-01-01

    Aquaporins (AQPs ) are expressed in most exocrine and endocrine secretory glands. Consequently, summarizing the expression and functions of AQPs in secretory glands represents a daunting task considering the important number of glands present in the body, as well as the number of mammalian AQPs - thirteen. The roles played by AQPs in secretory processes have been investigated in many secretory glands. However, despite considerable research, additional studies are clearly needed to pursue our understanding of the role played by AQPs in secretory processes. This book chapter will focus on summarizing the current knowledge on AQPs expression and function in the gastrointestinal tract , including salivary glands, gastric glands, Duodenal Brunner's gland, liver and gallbladder, intestinal goblets cells, exocrine and endocrine pancreas, as well as few other secretory glands including airway submucosal glands, lacrimal glands, mammary glands and eccrine sweat glands.

  8. Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

    Energy Technology Data Exchange (ETDEWEB)

    Teramoto, Atsushi, E-mail: teramoto@fujita-hu.ac.jp [Faculty of Radiological Technology, School of Health Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake, Toyoake, Aichi 470-1192 (Japan); Fujita, Hiroshi [Department of Intelligent Image Information, Division of Regeneration and Advanced Medical Sciences, Graduate School of Medicine, Gifu University, 1-1 Yanagido, Gifu 501-1194 (Japan); Yamamuro, Osamu; Tamaki, Tsuneo [East Nagoya Imaging Diagnosis Center, 3-4-26 Jiyugaoka, Chikusa-ku, Nagoya, Aichi 464-0044 (Japan)

    2016-06-15

    Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules

  9. Automated detection of pulmonary nodules in PET/CT images: Ensemble false-positive reduction using a convolutional neural network technique

    International Nuclear Information System (INIS)

    Teramoto, Atsushi; Fujita, Hiroshi; Yamamuro, Osamu; Tamaki, Tsuneo

    2016-01-01

    Purpose: Automated detection of solitary pulmonary nodules using positron emission tomography (PET) and computed tomography (CT) images shows good sensitivity; however, it is difficult to detect nodules in contact with normal organs, and additional efforts are needed so that the number of false positives (FPs) can be further reduced. In this paper, the authors propose an improved FP-reduction method for the detection of pulmonary nodules in PET/CT images by means of convolutional neural networks (CNNs). Methods: The overall scheme detects pulmonary nodules using both CT and PET images. In the CT images, a massive region is first detected using an active contour filter, which is a type of contrast enhancement filter that has a deformable kernel shape. Subsequently, high-uptake regions detected by the PET images are merged with the regions detected by the CT images. FP candidates are eliminated using an ensemble method; it consists of two feature extractions, one by shape/metabolic feature analysis and the other by a CNN, followed by a two-step classifier, one step being rule based and the other being based on support vector machines. Results: The authors evaluated the detection performance using 104 PET/CT images collected by a cancer-screening program. The sensitivity in detecting candidates at an initial stage was 97.2%, with 72.8 FPs/case. After performing the proposed FP-reduction method, the sensitivity of detection was 90.1%, with 4.9 FPs/case; the proposed method eliminated approximately half the FPs existing in the previous study. Conclusions: An improved FP-reduction scheme using CNN technique has been developed for the detection of pulmonary nodules in PET/CT images. The authors’ ensemble FP-reduction method eliminated 93% of the FPs; their proposed method using CNN technique eliminates approximately half the FPs existing in the previous study. These results indicate that their method may be useful in the computer-aided detection of pulmonary nodules

  10. Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer

    International Nuclear Information System (INIS)

    Jang, Hyeong Jun; Im, Chung Geun; Chun, Geum Sung; Jeong, Il Seon; Kim, Hoi Nam

    2008-01-01

    The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H and N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H and N cancer patient of CT On-rail System. The object of H and N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. The changes of target coordinate by the parotid gland movement are X: -0.4∼0.4 cm, Y: -0.4∼0.3 cm, Z: -0.3∼0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivery time.

  11. Adrenal Gland Disorders: Condition Information

    Science.gov (United States)

    ... About Share Facebook Twitter Pinterest Email Print About Adrenal Gland Disorders The adrenal glands, located on the top of ... as estrogen and testosterone. What are adrenal gland disorders? Adrenal gland disorders occur when the adrenal glands do not ...

  12. Output Position and Word Relatedness Effects in a DRM Paradigm: Support for a Dual-Retrieval Process Theory of Free Recall and False Memories

    Science.gov (United States)

    Barnhardt, T. M.; Choi, H.; Gerkens, D. R.; Smith, S. M.

    2006-01-01

    Five experiments investigated predictions--derived from a dual-retrieval process approach to free recall (Brainerd, C. J., Wright, R., Reyna, V. F., & Payne, D. G. (2002). Dual-retrieval processes in free and associative recall. Journal of Memory and Language, 46, 120-152.)--about false memories in a DRM-like paradigm. In all the experiments, the…

  13. CYP2W1 is highly expressed in adrenal glands and is positively associated with the response to mitotane in adrenocortical carcinoma.

    Directory of Open Access Journals (Sweden)

    Cristina L Ronchi

    Full Text Available Adrenocortical tumors comprise frequent adenomas (ACA and rare carcinomas (ACC. Human cytochrome P450 2W1 (CYP2W1 is highly expressed in some cancers holding the potential to activate certain drugs into tumor cytotoxins.To investigate the CYP2W1 expression in adrenal samples and its relationship with clinical outcome in ACC.CYP2W1 expression was investigated by qRT-PCR in 13 normal adrenal glands, 32 ACA, 25 ACC, and 9 different non-adrenal normal tissue samples and by immunohistochemistry in 352 specimens (23 normal adrenal glands, 33 ACA, 239 ACC, 67 non-adrenal normal or neoplastic samples.CYP2W1 mRNA expression was absent/low in normal non-adrenal tissues, but high in normal and neoplastic adrenal glands (all P<0.01 vs non-adrenal normal tissues. Accordingly, CYP2W1 immunoreactivity was absent/low (H-score 0-1 in 72% of non-adrenal normal tissues, but high (H-score 2-3 in 44% of non-adrenal cancers, in 65% of normal adrenal glands, in 62% of ACAs and in 50% of ACCs (all P<0.001 vs non-adrenal normal tissues, being significantly increased in steroid-secreting compared to non-secreting tumors. In ACC patients treated with mitotane only, high CYP2W1 immunoreactivity adjusted for ENSAT stage was associated with longer overall survival and time to progression (P<0.05 and P<0.01, respectively, and with a better response to therapy both as palliative (response/stable disease in 42% vs 6%, P<0.01 or adjuvant option (absence of disease recurrence in 69% vs 45%, P<0.01.CYP2W1 is highly expressed in both normal and neoplastic adrenal glands making it a promising tool for targeted therapy in ACC. Furthermore, CYP2W1 may represent a new predictive marker for the response to mitotane treatment.

  14. Abiotic production of nitrous oxide by lightning. Implications for a false positive identification of life on Earth-Like Planets around quiescent M Dwarfs

    Science.gov (United States)

    Navarro, Karina F.; Navarro-Gonzalez, Rafael; McKay, Christopher P.

    _{2} dominated primitive Earth-like atmospheres. However, during the rise in atmospheric O _{2} at the start of the Proterozoic, the ocean became stratified (anoxic at the bottom and oxygenic at the surface). During this period, the emissions of N _{2}O were probably higher than today associated with a stronger microbial activity in the early anoxic ocean layer (Grenfell et al., 2011). Under this scenario, the predicted N _{2}O concentration would be about 3920 ppb, considering 10% the current atmospheric O _{2} concentrations, 100 times higher the current microbial N _{2}O flux, and a fainter Sun (94.3%) (Grenfell et al., 2011). This concentration would be still undetectable (Grenfell et al., 2011). A completely different scenario could be expected in Earth-like planets orbiting M dwarfs, which are the most abundant stars in the galaxy, representing about 75% of the total stellar population. M stars exhibit a large range in activity levels from very low levels of chromospheric and coronal activity, the so-called “quiescent” to high levels, the so-called “active" states. Photochemical models predict that the N _{2}O concentration would only increase to about 1,000 ppb for the current Earth orbiting an active M star, but surprisingly up to about 1,000 ppm for the current Earth orbiting a quiescent M star (Segura et al., 2005). Therefore, N _{2}O becomes a promising biomarker. Under this scenario it is important to constrain the abiotic sources of N _{2}O under different atmospheric conditions to avoid a false positive identification of life. Here we report an experimental study of the effects of lightning discharges on the nitrogen fixation rate during the evolution of the Earth’s early atmosphere from 10 to 1 percent of carbon dioxide in molecular nitrogen. We extended our study from no methane up to 1,000 ppm CH _{4}, which would be applicable to the postbiotic Earth (Tian et al., 2011). Lightning was simulated in the laboratory by a plasma generated with a

  15. The accuracy of fine-needle aspiration cytology for diagnosis of parotid gland masses: a clinicopathological study of 114 patients

    Directory of Open Access Journals (Sweden)

    Jens Kristjan GUDMUNDSSON

    Full Text Available ABSTRACT Objective Fine-needle aspiration cytology is a valuable method for preoperative assessment of head and neck tumors. However, its accuracy in detection of salivary gland masses is controversial compared with other methods. The aim of this work was to evaluate the effectiveness and accuracy of fine-needle aspiration cytology (FNAC in the diagnosis of parotid gland masses. Material and Methods Over a 10-year period, 126 parotid gland masses were resected. Retrospective chart reviews of 114 patients were performed. The results of FNAC and final histological diagnosis were compared and the accuracy of FNAC was determined. Results Final histological evaluation revealed 11 malignant tumors and 103 benign lesions. Pleomorphic adenoma was the most common neoplasm (63%, followed by Warthin’s tumor (17.5%. The sensitivity of FNAC in detecting malignant tumors was 73% and the specificity was 97%. Positive predictive value (PPV was 73% and negative predictive value (NPV was 97%. The overall accuracy of FNAC in detecting parotid masses was 95%. False-negative diagnosis was found in mucoepidermoid carcinoma, acinic cell carcinoma, and epithelial-myoepithelial carcinoma whereas there was false-positive diagnosis in cases of pleomorphic adenoma and normal parotid gland tissue. Conclusion FNAC is a reliable minimally invasive diagnostic method with a high sensitivity in diagnosis of lesions in parotid glands. The sensitivity of detection of malignant tumors in parotid glands was low due to the biopsy technique used, and depended on tumor location. Postoperative complications decreased after superficial parotidectomy.

  16. Valve spindle gland

    International Nuclear Information System (INIS)

    Burda, Z.; Harazim, A.; Kerlin, K.

    1979-01-01

    A gland is proposed of the valve spindle designed for radioactive or otherwise harmful media, such as in nuclear power plant primary circuits. The gland is installed in the valve cover and consists of a primary and a secondary part and of a gland case partitioning the gland space into two chambers. The bottom face of the gland case is provided with a double-sided collar for controlling the elements of the bottom primary gland while the top face is provided with a removable flange. (M.S.)

  17. Assessment of skin sensitization under REACH: A case report on vehicle choice in the LLNA and its crucial role preventing false positive results.

    Science.gov (United States)

    Watzek, Nico; Berger, Franz; Kolle, Susanne Noreen; Kaufmann, Tanja; Becker, Matthias; van Ravenzwaay, Bennard

    2017-04-01

    In the EU, chemicals with a production or import volume in quantities of one metric ton per year or more have to be tested for skin sensitizing properties under the REACH regulation. The murine Local Lymph Node Assay (LLNA) and its modifications are widely used to fulfil the data requirement, as it is currently considered the first-choice method for in vivo testing to cover this endpoint. This manuscript describes a case study highlighting the importance of understanding the chemistry of the test material during testing for 'skin sensitization' of MCDA (mixture of 2,4- and 2,6-diamino-methylcyclohexane) with particular focus on the vehicle used. While the BrdU-ELISA modification of the LLNA using acetone/olive oil (AOO) as vehicle revealed expectable positive results. However, the concentration control analysis unexpectedly revealed an instability of MCDA in the vehicle AOO. Further studies on the reactivity showed MCDA to rapidly react with AOO under formation of various imine structures, which might have caused the positive LLNA result. The repetition of the LLNA using propylene glycol (PG) as vehicle did not confirm the positive results of the LLNA using AOO. Finally, a classification of MCDA as skin sensitizer according to the Globally Harmonized System (GHS) was not justified. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Mandatory vaccinations in European countries, undocumented information, false news and the impact on vaccination uptake: the position of the Italian pediatric society.

    Science.gov (United States)

    Bozzola, Elena; Spina, Giulia; Russo, Rocco; Bozzola, Mauro; Corsello, Giovanni; Villani, Alberto

    2018-06-14

    High rates of vaccination coverage are important in preventing infectious diseases. Enforcing mandatory vaccinations is one of the strategies that some Countries adopted to protect the community when vaccination coverage is not satisfactory. In Italy, in 2017 vaccination against diphtheria, tetanus, pertussis, hepatitis B, poliovirus, Haemophilus influenzae type b, measles, mumps, rubella and varicella became compulsory in childhood. In order to contrast vaccination policies, anti-vaccination campaigns contribute to the spread of fake news. Among them, there is the false information that Italy is the only one country with mandatory vaccination policy. Aim of our study is confronting vaccination policies in children under 18 months against among different European countries for the following vaccines: diphtheria, tetanus, pertussis, hepatitis B, poliovirus, Haemophilus influenzae type b, measles, mumps, rubella and varicella. Information on policies of mandatory or recommended vaccinations of the European Countries were gathered by ECDC and compared to the Italian one. European Countries recommend or contemplate compulsory vaccines. Among them, eleven Countries (35.4%) have mandatory vaccinations for at least one out of diphtheria, tetanus, pertussis, hepatitis B, poliovirus, Haemophilus influenzae type b, measles, mumps, rubella and varicella vaccine. Not only in Italy, vaccination against diphtheria, tetanus, pertussis, hepatitis B, poliovirus, Haemophilus influenzae type b, measles, mumps, rubella and varicella is mandatory in children under 18 months. Other European countries adopted compulsory policies in order to prevent the spread of infectious diseases and to protect the community.

  19. Adrenal Gland Cancer

    Science.gov (United States)

    ... either benign or malignant. Benign tumors aren't cancer. Malignant ones are. Most adrenal gland tumors are ... and may not require treatment. Malignant adrenal gland cancers are uncommon. Types of tumors include Adrenocortical carcinoma - ...

  20. MARVELS-1: A FACE-ON DOUBLE-LINED BINARY STAR MASQUERADING AS A RESONANT PLANETARY SYSTEM AND CONSIDERATION OF RARE FALSE POSITIVES IN RADIAL VELOCITY PLANET SEARCHES

    International Nuclear Information System (INIS)

    Wright, Jason T.; Roy, Arpita; Mahadevan, Suvrath; Wang, Sharon X.; Fleming, Scott W.; Ford, Eric B.; Payne, Matt; Lee, Brian L.; Ge, Jian; Wang, Ji; Crepp, Justin R.; Gaudi, B. Scott; Eastman, Jason; Pepper, Joshua; Cargile, Phillip; Stassun, Keivan G.; Ghezzi, Luan; González-Hernández, Jonay I.; Wisniewski, John; Dutra-Ferreira, Leticia

    2013-01-01

    We have analyzed new and previously published radial velocity (RV) observations of MARVELS-1, known to have an ostensibly substellar companion in a ∼6 day orbit. We find significant (∼100 m s –1 ) residuals to the best-fit model for the companion, and these residuals are naïvely consistent with an interior giant planet with a P = 1.965 days in a nearly perfect 3:1 period commensurability (|P b /P c – 3| –4 ). We have performed several tests for the reality of such a companion, including a dynamical analysis, a search for photometric variability, and a hunt for contaminating stellar spectra. We find many reasons to be critical of a planetary interpretation, including the fact that most of the three-body dynamical solutions are unstable. We find no evidence for transits, and no evidence of stellar photometric variability. We have discovered two apparent companions to MARVELS-1 with adaptive optics imaging at Keck; both are M dwarfs, one is likely bound, and the other is likely a foreground object. We explore false-alarm scenarios inspired by various curiosities in the data. Ultimately, a line profile and bisector analysis lead us to conclude that the ∼100 m s –1 residuals are an artifact of spectral contamination from a stellar companion contributing ∼15%-30% of the optical light in the system. We conclude that origin of this contamination is the previously detected RV companion to MARVELS-1, which is not, as previously reported, a brown dwarf, but in fact a G dwarf in a face-on orbit.

  1. A cause of false positive of the whole body scanning with iodine 131: obstructive hydronephrosis; Une cause de faux-positif du balayage corps entier a l'iode 131: l'hydronephrose obstructive

    Energy Technology Data Exchange (ETDEWEB)

    Sellem, A.; Elbez, I.; Rejeb, O.; Elkadri, N.; Hammami, H. [Service de medecine nucleaire, hopital Militaire, Tunis, (Tunisia)

    2009-05-15

    The objective is to report the case of a differentiated carcinoma of the thyroid with a false positive aspect to the whole-body scanning with iodine 131 in relation with an accumulation of the tracer at the level of an obstructive appearance hydronephrosis. (N.C.)

  2. Heat treatment and false-positive heartworm antigen testing in ex vivo parasites and dogs naturally infected by Dirofilaria repens and Angiostrongylus vasorum

    Directory of Open Access Journals (Sweden)

    Luigi Venco

    2017-11-01

    Full Text Available Abstract Background Heartworm antigen testing is considered sensitive and specific. Currently available tests are reported as detecting a glycoprotein found predominantly in the reproductive tract of the female worm and can reach specificity close to 100%. Main concerns regard sensitivity in the case of light infections, the presence of immature females or cases of all-male infections. Research and development have been aimed at increasing sensitivity. Recently, heat treatment of serum prior to antigen testing has been shown to result in an increase in positive antigen test results, presumably due to disruption of natural antigen–antibody complexes. Cross-reactions in dogs with both natural and experimental infections with Angiostrongylus vasorum and Spirocerca lupi have been reported, but cross-reactions with other helminths have not been extensively studied. In order to evaluate potential cross-reactivity with other canine and feline parasites, two studies were performed. Study 1: Live adults of Dirofilaria immitis, Dirofilaria repens, Toxocara canis, Toxocara cati, Dipylidium caninum, Taenia taeniaeformis and Mesocestoides spp. larvae were washed and incubated in tubes with saline solution. All worms were alive at the time of removal from the saline. Saline solutions containing excretory/secretory antigens were then tested for heartworm with six different, commercially available antigen tests. All results were evaluated blind by three of the authors. Study 2: Sera from dogs with natural infections by A. vasorum or D. repens, living in areas free of heartworm disease, were tested with the same tests before and after heat treatment (103 °C for 10 min. Results Results suggest that antigens detected by currently available tests are not specific for D. immitis. They may give positive results through detection of different parasites’ antigens that are normally not released into the bloodstream or released in a low amount and/or bound to

  3. Brain modulation of Dufour's gland ester biosynthesis in vitro in the honeybee ( Apis mellifera)

    Science.gov (United States)

    Katzav-Gozansky, Tamar; Hefetz, Abraham; Soroker, Victoria

    2007-05-01

    Caste-specific pheromone biosynthesis is a prerequisite for reproductive skew in the honeybee. Nonetheless, this process is not hardwired but plastic, in that egg-laying workers produce a queen-like pheromone. Studies with Dufour’s gland pheromone revealed that, in vivo, workers’ gland biosynthesis matches the social status of the worker, i.e., sterile workers showed a worker-like pattern whereas fertile workers showed a queen-like pattern (production of the queen-specific esters). However, when incubated in vitro, the gland spontaneously exhibits the queen-like pattern, irrespective of its original worker type, prompting the notion that ester production in workers is under inhibitory control that is queen-dependent. We tested this hypothesis by exposing queen or worker Dufour’s glands in vitro to brain extracts of queens, queenright (sterile) workers and males. Unexpectedly, worker brain extracts activated the queen-like esters biosynthesis in workers’ Dufour’s gland. This stimulation was gender-specific; queen or worker brains demonstrated a stimulatory activity, but male brains did not. Queen gland could not be further stimulated. Bioassays with heated and filtered extracts indicate that the stimulatory brain factor is below 3,000 Da. We suggest that pheromone production in Dufour’s gland is under dual, negative positive control. Under queenright conditions, the inhibitor is released and blocks ester biosynthesis, whereas under queenless conditions, the activator is released, activating ester biosynthesis in the gland. This is consistent with the hypothesis that queenright workers are unequivocally recognized as non-fertile, whereas queenless workers try to become “false queens” as part of the reproductive competition.

  4. Different percentages of false-positive results obtained using five methods for the calculation of reference change values based on simulated normal and ln-normal distributions of data

    DEFF Research Database (Denmark)

    Lund, Flemming; Petersen, Per Hyltoft; Fraser, Callum G

    2016-01-01

    a homeostatic set point that follows a normal (Gaussian) distribution. This set point (or baseline in steady-state) should be estimated from a set of previous samples, but, in practice, decisions based on reference change value are often based on only two consecutive results. The original reference change value......-positive results. The aim of this study was to investigate false-positive results using five different published methods for calculation of reference change value. METHODS: The five reference change value methods were examined using normally and ln-normally distributed simulated data. RESULTS: One method performed...... best in approaching the theoretical false-positive percentages on normally distributed data and another method performed best on ln-normally distributed data. The commonly used reference change value method based on two results (without use of estimated set point) performed worst both on normally...

  5. Evaluation of HIV testing algorithms in Ethiopia: the role of the tie-breaker algorithm and weakly reacting test lines in contributing to a high rate of false positive HIV diagnoses.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Kliescikova, Jarmila; Pearce, Neil; Ariti, Cono; Muluneh, Libsework; Pirou, Erwan; Ritmeijer, Koert; Masiga, Johnson; Abebe, Almaz

    2015-02-03

    In Ethiopia a tiebreaker algorithm using 3 rapid diagnostic tests (RDTs) in series is used to diagnose HIV. Discordant results between the first 2 RDTs are resolved by a third 'tiebreaker' RDT. Médecins Sans Frontières uses an alternate serial algorithm of 2 RDTs followed by a confirmation test for all double positive RDT results. The primary objective was to compare the performance of the tiebreaker algorithm with a serial algorithm, and to evaluate the addition of a confirmation test to both algorithms. A secondary objective looked at the positive predictive value (PPV) of weakly reactive test lines. The study was conducted in two HIV testing sites in Ethiopia. Study participants were recruited sequentially until 200 positive samples were reached. Each sample was re-tested in the laboratory on the 3 RDTs and on a simple to use confirmation test, the Orgenics Immunocomb Combfirm® (OIC). The gold standard test was the Western Blot, with indeterminate results resolved by PCR testing. 2620 subjects were included with a HIV prevalence of 7.7%. Each of the 3 RDTs had an individual specificity of at least 99%. The serial algorithm with 2 RDTs had a single false positive result (1 out of 204) to give a PPV of 99.5% (95% CI 97.3%-100%). The tiebreaker algorithm resulted in 16 false positive results (PPV 92.7%, 95% CI: 88.4%-95.8%). Adding the OIC confirmation test to either algorithm eliminated the false positives. All the false positives had at least one weakly reactive test line in the algorithm. The PPV of weakly reacting RDTs was significantly lower than those with strongly positive test lines. The risk of false positive HIV diagnosis in a tiebreaker algorithm is significant. We recommend abandoning the tie-breaker algorithm in favour of WHO recommended serial or parallel algorithms, interpreting weakly reactive test lines as indeterminate results requiring further testing except in the setting of blood transfusion, and most importantly, adding a confirmation test

  6. PET Study with false positive {sup 68}Ga-Dotatate caused by the presence of an accessory spleen; Estudio PET con {sup 68}Ga-Dotatate falso positivo causado por la presencia de un bazo accesorio

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago / Seccion Medicina Nuclear, Departamento Medicina, Hospital Clinico Universidad de Chile. Santiago (Chile); Jofre, Josefina; Sierralta, M. Paulina; Canessa, Jose [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago. Santiago (Chile)

    2013-05-31

    Neuroendocrine tumors with somatostatin receptor expression are suitable for imaging with somatostatin analogues. {sup 68}Ga-labeled peptides are useful for the diagnosis, staging and assessment of therapeutic response of these tumors. However, for a correct interpretation it is necessary to know the normal biodistribution of somatostatin receptors in the body. Asymmetric adrenal uptake may be a normal variant to cause confusion, or an accessory or ectopic spleen can lead to a false positive result. We report a case of asymmetric adrenal uptake which was correctly considered as a normal variant, but an accessory spleen caused the false impression of being a metastasis from a previously resected primary carcinoid tumor.

  7. HAMS: High-Affinity Mass Spectrometry Screening. A High-Throughput Screening Method for Identifying the Tightest-Binding Lead Compounds for Target Proteins with No False Positive Identifications.

    Science.gov (United States)

    Imaduwage, Kasun P; Go, Eden P; Zhu, Zhikai; Desaire, Heather

    2016-11-01

    A major challenge in drug discovery is the identification of high affinity lead compounds that bind a particular target protein; these leads are typically identified by high throughput screens. Mass spectrometry has become a detection method of choice in drug screening assays because the target and the ligand need not be modified. Label-free assays are advantageous because they can be developed more rapidly than assays requiring labels, and they eliminate the risk of the label interfering with the binding event. However, in commonly used MS-based screening methods, detection of false positives is a major challenge. Here, we describe a detection strategy designed to eliminate false positives. In this approach, the protein and the ligands are incubated together, and the non-binders are separated for detection. Hits (protein binders) are not detectable by MS after incubation with the protein, but readily identifiable by MS when the target protein is not present in the incubation media. The assay was demonstrated using three different proteins and hundreds of non-inhibitors; no false positive hits were identified in any experiment. The assay can be tuned to select for ligands of a particular binding affinity by varying the quantity of protein used and the immobilization method. As examples, the method selectively detected inhibitors that have K i values of 0.2 μM, 50 pM, and 700 pM. These findings demonstrate that the approach described here compares favorably with traditional MS-based screening methods. Graphical Abstract ᅟ.

  8. Chemical applicability domain of the Local Lymph Node Assay (LLNA) for skin sensitisation potency. Part 3. Apparent discrepancies between LLNA and GPMT sensitisation potential: False positives or differences in sensitivity?

    Science.gov (United States)

    Roberts, David W; Schultz, Terry W; Api, Anne Marie

    2016-10-01

    The Local Lymph Node Assay (LLNA) is the gold standard regulatory toxicology test for skin sensitisation along with the guinea pig maximisation test (GPMT). Compared with the GPMT, LLNA uses fewer animals, it is quantitative, and it gives a numerical prediction of potency. However several concerns have been raised with this assay, mainly related to false positives and false negatives. Over the years, many authors, including the developers of the assay, have presented cases where there have been discrepancies between the GMPT and LLNA results. Several theories have been put forward for these discrepancies, the main one being the "over-sensitivity" of the GPMT. This paper analyses the data from a systematic study, published in three papers from 2008 to 2011, covering several classes of chemicals, in particular unsaturated fatty acids, sugar surfactants and ethoxylated alcohols, with many cases of chemicals testing positive in the LLNA being negative in the GPMT. Based on consideration of reaction chemistry and structural alerts, it is concluded that these discrepancies are not LLNA false positives, but can be rationalised in terms of the different protocols of the assays. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Vasoactive intestinal polypeptide (VIP) innervation of the human eyelid glands.

    Science.gov (United States)

    Seifert, P; Spitznas, M

    1999-06-01

    This study was conducted to obtain morphological proof of innervating nerve fibres in the glands of the human eyelid (accessory lacrimal glands of Wolfring, meibomian glands, goblet cells, glands of Zeis, glands of Moll, sweat glands, glands of lanugo hair follicles) and identification of the secretomotorically active neuropeptide vasoactive intestinal polypeptide (VIP) as a common transmitter. Epoxy-embedded ultrathin sections of tissue samples from human eyelids were studied using electron microscopy. Paraffin sections fixed in Bouin-Hollande solution were immunostained with rabbit antiserum against VIP. With the electron microscope we were able to identify nerves in the glandular stroma of all the glands examined with the exception of goblet cells. Intraepithelial single axons were only seen in the parenchyma of Wolfring glands. The morphological findings corresponded with the immunological finding of VIP-positive, nerve-like structures in the same locations, with the exception of lanugo hair follicle glands, and goblet cells. Our findings indicate that the glands of the eyelids and main lacrimal gland represent a functional unit with VIP as a possible common stimulating factor. Copyright 1999 Academic Press.

  10. Modeling Kepler Transit Light Curves as False Positives: Rejection of Blend Scenarios for Kepler-9, and Validation of Kepler-9 d, a Super-Earth-Size Planet in a Multiple System

    Science.gov (United States)

    Torres, Guillermo; Fressin, Francois; Batalha, Natalie M.; Borucki, William J.; Brown, Timothy M.; Bryson, Stephen T.; Buchhave, Lars A.; Charbonneau, David; Ciardi, David R.; Dunham, Edward W.; hide

    2011-01-01

    Light curves from the Kepler Mission contain valuable information on the nature of the phenomena producing the transit-like signals. To assist in exploring the possibility that they are due to an astrophysical false positive we describe a procedure (BLENDER) to model the photometry in terms of a blend rather than a planet orbiting a star. A blend may consist of a background or foreground eclipsing binary (or star-planet pair) whose eclipses are attenuated by the light of the candidate and possibly other stars within the photometric aperture. We apply BLENDER to the case of Kepler-9 (KIC 3323887), a target harboring two previously confirmed Saturn-size planets (Kepler-9 b and Kepler-9 c) showing transit timing variations, and an additional shallower signal with a 1.59 day period suggesting the presence of a super-Earth-size planet. Using BLENDER together with constraints from other follow-up observations we are able to rule out all blends for the two deeper signals and provide independent validation of their planetary nature. For the shallower signal, we rule out a large fraction of the false positives that might mimic the transits. The false alarm rate for remaining blends depends in part (and inversely) on the unknown frequency of small-size planets. Based on several realistic estimates of this frequency, we conclude with very high confidence that this small signal is due to a super-Earth-size planet (Kepler-9 d) in a multiple system, rather than a false positive. The radius is determined to be 1.64(exp)(sub-14),R, and current spectroscopic observations are as yet insufficient to establish its mass.

  11. Immunohistochemical sweat gland profiles.

    Science.gov (United States)

    Noël, Fanchon; Piérard, Gérald E; Delvenne, Philippe; Quatresooz, Pascale; Humbert, Philippe; Piérard-Franchimont, Claudine

    2013-09-01

    Human sweat glands are heterogeneous in their structures and functions. Accordingly, eccrine, apocrine, and apoeccrine glands are distinguished. Some immunohistochemical markers are expected to distinguish the sweat gland types in their secretory and excretory parts. This study used two sets of antibodies. The first panel was composed of antibodies directed to well-defined sweat gland structures. The molecular targets included the low-molecular-weight cytokeratins CAM 5.2, the S100-B protein, the epithelial membrane antigen (EMA), the carcinoembryonic antigen (CEA), and the lectin Ulex europaeus agglutinin-1 (UEA-1). A second exploratory panel of antibodies targeted syndecan-1 (CD138), NKI-C3 (CD63), and CD68. They were used to disclose some undescribed antigen expressions in human sweat glands. The first set of antibodies confirmed previous findings. The immunoreactivities of the three sweat gland types were similar in the excretory ducts. By contrast, they were distinguished in the deeper coiled secretory portions of the glands. Clues supporting their distinction and probably their functional activity were obtained by immunohistochemistry using the S100-B protein, CEA and CD63 antibodies. The immunoreactivity to the S100-B protein, CEA and CD63 possibly help identifying apoeccrine sweat glands or a peculiar functional activity of eccrine sweat glands. © 2013 Wiley Periodicals, Inc.

  12. Dysfunctional ectopic thyroid gland: A case report

    Directory of Open Access Journals (Sweden)

    Stokić Edita

    2014-01-01

    Full Text Available Introduction. Lingual thyroid gland is a rare anomaly of thyroid gland development, occurring more frequently in females. If it causes local symptomatology such as dysphagia, dysphonia or dyspnea it is diagnosed in childhood, however, if it is asymptomatic it is usually diagnosed in adulthood. Case Outline. We present a 23-year-old female patient in whom we diagnosed lingual thyroid gland coincidentally during diagnostic procedures of a concomitant disease. The application of 131I scintigraphy showed an oval field of intensive accumulation of radio markers in the zone of medial face line, around tongue base, with the absence of thyroid gland in its physiological position. Functional testing proved primary hypothyroidism and we started the application of substitution therapy. The application of levothyroxine resulted in reaching euthyroid state and the reduction of thyroid gland size. Conclusion. We present a very rare anomaly of the thyroid gland, and so far there have been no clear attitudes about further treatment. The general condition of the patient, age, the size of ectopic thyroid gland and the existence of local symptomatology or complications represent the factors that have influence on the choice of treatment method.

  13. Salivary Gland Secretion.

    Science.gov (United States)

    Dorman, H. L.; And Others

    1981-01-01

    Describes materials and procedures for an experiment utilizing a live dog to demonstrate: (1) physiology of the salivary gland; (2) parasympathetic control of the salivary gland; (3) influence of varying salivary flow rates on sodium and potassium ions, osmolarity and pH; and (4) salivary secretion as an active process. (DS)

  14. Salivary Gland Cancer

    Science.gov (United States)

    ... contains antibodies that can kill germs. Salivary gland cancer is a type of head and neck cancer. It is rare. It may not cause any ... pain in your face Doctors diagnose salivary gland cancer using a physical exam, imaging tests, and a ...

  15. Proton receptor GPR68 expression in dendritic-cell-like S100β-positive cells of rat anterior pituitary gland: GPR68 induces interleukin-6 gene expression in extracellular acidification.

    Science.gov (United States)

    Horiguchi, Kotaro; Higuchi, Masashi; Yoshida, Saishu; Nakakura, Takashi; Tateno, Kozue; Hasegawa, Rumi; Takigami, Shu; Ohsako, Shunji; Kato, Takako; Kato, Yukio

    2014-11-01

    S100β-positive cells, which do not express the classical pituitary hormones, appear to possess multifunctional properties and are assumed to be heterogeneous in the anterior pituitary gland. The presence of several protein markers has shown that S100β-positive cells are composed of populations such as stem/progenitor cells, epithelial cells, astrocytes and dendritic cells. Recently, we succeeded in separating S100β-positive cells into round-cell (dendritic-cell-like) and process-cell types. We also found the characteristic expression of anti-inflammatory factors (interleukin-6, Il-6) and membrane receptors (integrin β-6) in the round type. Here, we further investigate the function of the subpopulation of S100β-positive cells. Since IL-6 is also a paracrine factor that regulates hormone producing-cells, we examine whether a correlation exists among extracellular acid stress, IL-6 and hormone production by using primary cultures of anterior pituitary cells. Dendritic-cell-like S100β-positive cells notably expressed Gpr68 (proton receptor) and Il-6. Furthermore, the expression of Il-6 and proopiomelanocortin (Pomc) was up-regulated by extracellular acidification. The functional role of IL-6 and GPR68 in the gene expression of Pomc during extracellular acidification was also examined. Small interfering RNA for Il-6 up-regulated Pomc expression and that for Gpr68 reversed the down-regulation of Il-6 and up-regulated Pomc expression by extracellular acidification. Thus, S100β-positive dendritic-like cells can sense an increase in extracellular protons via GPR68 and respond by the production of IL-6 in order to suppress the up-regulation of Pomc expression.

  16. Coinfection of hepatitis A virus genotype IA and IIIA complicated with autoimmune hemolytic anemia, prolonged cholestasis, and false-positive immunoglobulin M anti-hepatitis E virus: a case report.

    Science.gov (United States)

    Kim, Hee Sup; Jeong, Sook Hyang; Jang, Je Hyuck; Myung, Hyung Joon; Kim, Jin Wook; Bang, Soo Mee; Song, Sang Hoon; Kim, Haeryoung; Yun, Hae Sun

    2011-12-01

    A 37-year-old male presented with fever and jaundice was diagnosed as hepatitis A complicated with progressive cholestasis and severe autoimmune hemolytic anemia. He was treated with high-dose prednisolone (1.5 mg/kg), and eventually recovered. His initial serum contained genotype IA hepatitis A virus (HAV), which was subsequently replaced by genotype IIIA HAV. Moreover, at the time of development of hemolytic anemia, he became positive for immunoglobulin M (IgM) anti-hepatitis E virus (HEV). We detected HAV antigens in the liver biopsy specimen, while we detected neither HEV antigen in the liver nor HEV RNA in his serum. This is the first report of hepatitis A coinfected with two different genotypes manifesting with autoimmune hemolytic anemia, prolonged cholestasis, and false-positive IgM anti-HEV.

  17. Comparison of false-negative/positive results of intraoperative evoked potential monitoring between no and partial neuromuscular blockade in patients receiving propofol/remifentanil-based anesthesia during cerebral aneurysm clipping surgery: A retrospective analysis of 685 patients.

    Science.gov (United States)

    Kim, Sung-Hoon; Jin, Seok-Joon; Karm, Myong-Hwan; Moon, Young-Jin; Jeong, Hye-Won; Kim, Jae-Won; Ha, Seung-Il; Kim, Joung-Uk

    2016-08-01

    Although the elicited responses of motor evoked potential (MEP) monitoring are very sensitive to suppression by anesthetic agents and muscle relaxants, the use of neuromuscular blockade (NMB) during MEP monitoring is still controversial because of serious safety concerns and diagnostic accuracy. Here, we evaluated the incidence of unacceptable movement and compared false-negative MEP results between no and partial NMB during cerebral aneurysm clipping surgery. We reviewed patient medical records for demographic data, anesthesia regimen, neurophysiology event logs, MEP results, and clinical outcomes. Patients were divided into 2 groups according to the intraoperative use of NMB: no NMB group (n = 276) and partial NMB group (n = 409). We compared the diagnostic accuracy of MEP results to predict postoperative outcomes between both groups. Additionally, we evaluated unwanted patient movement during MEP monitoring in both groups. Of the 685 patients, 622 (90.8%) manifested no intraoperative changes in MEP and no postoperative motor deficits. Twenty patients showed postoperative neurologic deficits despite preserved intraoperative MEP. False-positive MEP results were 3.6% in the no NMB group and 3.9% in the partial NMB group (P = 1.00). False-negative MEP results were 1.1% in the no NMB group and 4.2% in the partial NMB group (P = 0.02). No spontaneous movement or spontaneous respiration was observed in either group. Propofol/remifentanil-based anesthesia without NMB decreases the stimulation intensity of MEPs, which may reduce the false-negative ratio of MEP monitoring during cerebral aneurysm surgery. Our anesthetic protocol enabled reliable intraoperative MEP recording and patient immobilization during cerebral aneurysm clipping surgery.

  18. Intercellular communications within the rat anterior pituitary. XVI: postnatal changes of distribution of S-100 protein positive cells, connexin 43 and LH-RH positive sites in the pars tuberalis of the rat pituitary gland. An immunohistochemical and electron microscopic study.

    Science.gov (United States)

    Wada, Ikuo; Sakuma, Eisuke; Shirasawa, Nobuyuki; Wakabayashi, Kenjiro; Otsuka, Takanobu; Hattori, Kazuki; Yashiro, Takashi; Herbert, Damon C; Soji, Tsuyoshi

    2014-02-01

    The architecture of luteinizing hormone-releasing hormone (LH-RH) nerve ends and the S-100 protein containing folliculo-stellate cells forming gap junctions in the pars tuberalis is basically important in understanding the regulation of the hormone producing mechanism of anterior pituitary glands. In this study, intact male rats 5-60 days old were prepared for immunohistochemistry and electron microscopy. From immunostained sections, the S-100 containing cells in pars tuberalis were first detected on day 30 and increased in number to day 60; this was parallel to the immunohistochemical staining of gap junction protein, connexin 43. LH-RH positive sites were clearly observed on just behind the optic chiasm and on the root of pituitary stalk on day 30. On day 60, the width of layer increased, while follicles and gap junctions were frequently observed between agranular cells in 10 or more layers of pars tuberalis. In the present study, we investigated the sexual maturation of the anterior pituitary glands through the postnatal development of S-100 positive cells, connexin 43 and LH-RH nerves. It is suggested that the folliculo-stellate cell system including the LH-RH neurons in the pars tuberalis participates in the control of LH secretion along with the portal vein system. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. [The pathology of salivary glands. Tumors of the salivary glands].

    Science.gov (United States)

    Mahy, P; Reychler, H

    2006-01-01

    The management of benign and malignant neoplasms of the salivary glands requires precise knowledge of tumor histogenesis and classification as well as surgical skills. Pleomorphic adenoma and Whartin's tumor are the most frequent tumors in parotid glands while the probability for malignant tumors is higher in other glands, especially in sublingual and minor salivary glands. Those malignant salivary glands tumors are rare and necessitate multidisciplinar staging and management in close collaboration with the pathologist and the radiation oncologist.

  20. Adrenal Gland Disorders

    Science.gov (United States)

    ... Cushing's syndrome, there's too much cortisol, while with Addison's disease, there is too little. Some people are born unable to make enough cortisol. Causes of adrenal gland disorders include Genetic mutations Tumors ...

  1. Mammary gland stem cells

    DEFF Research Database (Denmark)

    Fridriksdottir, Agla J R; Petersen, Ole W; Rønnov-Jessen, Lone

    2011-01-01

    Distinct subsets of cells, including cells with stem cell-like properties, have been proposed to exist in normal human breast epithelium and breast carcinomas. The cellular origins of epithelial cells contributing to gland development, tissue homeostasis and cancer are, however, still poorly...... and differences between mouse and human gland development with particular emphasis on the identity and localization of stem cells, and the influence of the surrounding microenvironment. It is concluded that while recent advances in the field have contributed immense insight into how the normal mammary gland...... develops and is maintained, significant discrepancies exist between the mouse and human gland which should be taken into consideration in current and future models of mammary stem cell biology....

  2. Radionuclide salivary gland imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mishkin, F.S.

    1981-10-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific.

  3. Radionuclide salivary gland imaging

    International Nuclear Information System (INIS)

    Mishkin, F.S.

    1981-01-01

    Salivary gland imaging with 99mTc as pertechnetate provides functional information concerning trapping and excretion of the parotid and submandibular glands. Anatomic information gained often adds little to clinical evaluation. On the other hand, functional information may detect subclinical involvement, which correlates well with biopsy of the minor labial salivary glands. Salivary gland abnormalities in systemic disease such as sarcoidosis, rheumatoid arthritis, lupus erythematosus, and other collagenvascular disorders may be detected before they result in the clinical manifestaions of Sjoegren's syndrome. Such glands, after initially demonstrating increased trapping in the acute phase, tend to have decreased trapping and failure to discharge pertechnetate in response to an appropriate physiologic stimulus. Increased uptake of gallium-67 citrate often accompanies these findings. Inflammatory parotitis can be suspected when increased perfusion is evident on radionuclide angiography with any agent. The ability of the salivary gland image to detect and categorize mass lesions, which result in focal areas of diminished activity such as tumors, cysts, and most other masses, is disappointing, while its ability to detect and categorize Warthin's tumor, which concentrates pertechnetate, is much more valuable, although not specific

  4. False-positive uptake on 2-[18F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography/computed tomography (PET/CT) in oncological imaging

    International Nuclear Information System (INIS)

    Culverwell, A.D.; Scarsbrook, A.F.; Chowdhury, F.U.

    2011-01-01

    With the increasing utilization of integrated positron-emission tomography/computed tomography (PET/CT) using the glucose analogue 2-[ 18 F]-fluoro-2-deoxy-D-glucose (FDG) in oncological imaging, it is important for radiologists and nuclear medicine physicians to be aware that FDG uptake is not specific for malignancy, as many different physiological variants and benign pathological conditions can also exhibit increased glucose metabolism. Such false-positive FDG uptake often arises outside the area of primary interest and may mimic malignant disease, thereby confounding accurate interpretation of PET/CT studies. With the use of illustrative clinical cases, this article will provide a systematic overview of potential interpretative pitfalls and illustrate how such unexpected findings can be appropriately evaluated.

  5. Malignant salivary gland tumours

    International Nuclear Information System (INIS)

    Thompson, S.H.

    1982-01-01

    The most frequent malignant salivary gland tumours are the mucoepidermoid tumour, adenoid cystic carcinoma and adenocarcinoma. The major salivary glands and the minor glands of the mouth and upper respiratory tract may potentially develop any of these malignant lesions. Malignant lesions most frequently present as a palpable mass and tend to enlarge more rapidly than benign neoplasms. Pain, paresthesia, muscle paralysis and fixation to surrounding tissue are all ominous signs and symptoms. The only reliable means of differential diagnosis of these lesions is biopsy and histologic analysis. Therapy involves surgery or a combination of surgery and radiation therapy. The ultimate prognosis is governed by the intrinsic biologic behaviour of the neoplasms, the extent of disease and adequate clinical therapy

  6. Malignant salivary gland tumours

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, S.H. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Oral Pathology)

    1982-08-01

    The most frequent malignant salivary gland tumours are the mucoepidermoid tumour, adenoid cystic carcinoma and adenocarcinoma. The major salivary glands and the minor glands of the mouth and upper respiratory tract may potentially develop any of these malignant lesions. Malignant lesions most frequently present as a palpable mass and tend to enlarge more rapidly than benign neoplasms. Pain, paresthesia, muscle paralysis and fixation to surrounding tissue are all ominous signs and symptoms. The only reliable means of differential diagnosis of these lesions is biopsy and histologic analysis. Therapy involves surgery or a combination of surgery and radiation therapy. The ultimate prognosis is governed by the intrinsic biologic behaviour of the neoplasms, the extent of disease and adequate clinical therapy.

  7. Systemic True False

    African Journals Online (AJOL)

    Preferred Customer

    ):. (a). (b). (c). (d). Answer: True systemics are (b & c); False Systemics (a & d). For more examples, see (10 and 11). Na2O2. NaCl. Na. HCl heat /excess. (O). 300°C electrolysis. (molten). NaOH. NaCl. Na. HCl. H2O electrolysis. (solution). NaCl.

  8. Postoperative Submandibular Gland Swelling following Craniotomy under General Anesthesia

    Directory of Open Access Journals (Sweden)

    Haruka Nakanishi

    2015-01-01

    Full Text Available Objective. Reporting of a rare case of postoperative submandibular gland swelling following craniotomy. Case Report. A 33-year-old male underwent resection for a brain tumor under general anesthesia. The tumor was resected via a retrosigmoid suboccipital approach and the patient was placed in a lateral position with his face down and turned to the right. Slight swelling of the right submandibular gland was observed just after the surgery. Seven hours after surgery, edematous change around the submandibular gland worsened and he required emergent reintubation due to airway compromise. The cause of submandibular gland swelling seemed to be an obstruction of the salivary duct due to surgical positioning. Conclusion. Once submandibular swelling and edematous change around the submandibular gland occur, they can worsen and compromise the air way within several hours after operation. Adequate precaution must be taken for any predisposing skull-base surgery that requires strong cervical rotation and flexion.

  9. Histology of the venom gland of the puff-adder (Bitis arietans)

    African Journals Online (AJOL)

    state. No accessory venom gland was found to be associated with the main venom gland or duct in the same position as has been reported for other snakes. In the resting state the parenchyma of the venom gland was found to consist of tubules lined by a single layer of tall columnar secretory cells. After being stimulated to ...

  10. Lacrimal gland ductal carcinomas

    DEFF Research Database (Denmark)

    Andreasen, Simon; Grauslund, Morten; Heegaard, Steffen

    2017-01-01

    and xerophtalmia; case 2: A 53-year-old man, presented with headache, proptosis and chemosis and case 3: A 73-year-old man, presenting with chemosis and a corneal abscess. All three cases were characterized morphologically including immunohistochemistry and genetically with fluorescence in situ hybridization (FISH...... HER2 amplification was found in cases 2 and 3. CONCLUSION: This study identified a spectrum of genetic events and pattern of protein expression in DC of the lacrimal gland similar to a subset of carcinomas of the breast and ductal carcinomas of the salivary glands. For therapeutic purposes...

  11. The diagnosis of nonclassic congenital adrenal hyperplasia due to 21-hydroxylase deficiency, based on serum basal or post-ACTH stimulation 17-hydroxyprogesterone, can lead to false-positive diagnosis.

    Science.gov (United States)

    Ambroziak, Urszula; Kępczyńska-Nyk, Anna; Kuryłowicz, Alina; Małunowicz, Ewa Maria; Wójcicka, Anna; Miśkiewicz, Piotr; Macech, Magdalena

    2016-01-01

    As nonclassic congenital adrenal hyperplasia (NCCAH) needs to be taken into account in women with hyperandrogenism, we aimed to assess whether the recommended level of poststimulated 17OHP ≥30 nmol/l confirms NCCAH. Forty, consecutive women with biochemical and/or clinical hyperandrogenism (aged 25·4, 18-38) suspected of having NCCAH were recruited to the study. In patients with 17OHP level between 5·1 and 29·9 nmol/l an ACTH stimulation test was performed. In patients with basal or poststimulated 17OHP ≥30 nmol/l, twenty-four-hour urinary steroid profile (USP) analysis was performed and CYP21A2 mutation was assessed. In selected patients with poststimulated 17OHP basal or poststimulated 17OHP ≥30 nmol/l (group A) and with poststimulated 17OHP basal or poststimulated 17OHP ≥30 nmol/l was found in 21, but NCCAH was confirmed by USP followed by genetic testing only in 5 (24%). Four patients were diagnosed as heterozygotes, and in twelve, no CYP21A2 mutation was detected. The diagnosis of NCCAH based only on serum 17OHP measurements (basal or poststimulated) may lead to false-positive diagnosis when performed by immunoassay with a cut-off value of ≥30 nmol/l. The definitive diagnosis can be established based on USP and/or genetic testing. © 2015 John Wiley & Sons Ltd.

  12. Computed tomography of the adrenal glands

    International Nuclear Information System (INIS)

    Buck, J.; Reiser, U.; Heuck, F.

    1982-01-01

    Whole body CT opens a third dimension - in addition with the advantage of being a non-invasive method with relatively negligible risk. Both, the normal CT findings of the adrenal gland and the normal variants in shape and position are described. With help of morphometry and image processing measurements of the size of the adrenal gland of 20 healthy patients were made and are listed; not only the respective normal variants but also hypo-hyperplasia are pointed out. Some examples are suitable for the illustration of pathologic conditions, such as inflammation and benign and malignant primary and secondary neoplasis. Finally, the value of adrenal gland CT is discussed with reference to the other radiologic methods. (orig.)

  13. Major salivary glands

    International Nuclear Information System (INIS)

    Mancuso, A.A.

    1985-01-01

    This chapter deals with two important features of treatment of malignant tumors of the parotid and submandibular gland: the lack of a satisfactory means of staging these lesions, and the all-important treatment considerations relative to the facial nerve in parotid gland malignancies. The imaging physician and the clinician should also consider that many suspected parotid mass lesions turn out to arise from structures extrinsic to the gland. The authors discuss in detail the sources of such mass lesions as well as how CT can be used to differentiate these from intrinsic lesions in the parotid and submandibular glands. Computed tomography and, perhaps in the near future, magnetic resonance imaging (MRI) will provide us with a means to diagnose these tumors earlier. This is especially true when studies are used in situations such as unexplained peripheral seventh nerve paralysis or in the early screening of patients with parotid or periparotid masses. Unfortunately, it is usually patient delay that leads to late diagnosis of palpable mass lesions in this region, and there is little that any imaging study can do to reduce this factor

  14. Baryogenesis in false vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Yuta [KEK Theory Center, IPNS, KEK, Tsukuba, Ibaraki (Japan); Yamada, Masatoshi [Kanazawa University, Institute for Theoretical Physics, Kanazawa (Japan)

    2017-09-15

    The null result in the LHC may indicate that the standard model is not drastically modified up to very high scales, such as the GUT/string scale. Having this in the mind, we suggest a novel leptogenesis scenario realized in the false vacuum of the Higgs field. If the Higgs field develops a large vacuum expectation value in the early universe, a lepton number violating process is enhanced, which we use for baryogenesis. To demonstrate the scenario, several models are discussed. For example, we show that the observed baryon asymmetry is successfully generated in the standard model with higher-dimensional operators. (orig.)

  15. O método da falsa posição na história e na educação matemática The false position method in history and in mathematics education

    Directory of Open Access Journals (Sweden)

    Cleide Farias de Medeiros

    2004-12-01

    Full Text Available Este texto coloca em uma perspectiva histórica o tratamento algébrico precoce que, costumeiramente, é dedicado ao ensino elementar da Aritmética. Defendendo que um tal tratamento algébrico precoce carrega vários pontos negativos para a formação do educando, o texto discute o "método da falsa posição" como uma alternativa viável para um tal ensino introdutório. Apontando as raízes históricas de tal método, o texto procura evidenciar as origens, aplicações e várias formas de visualizar este procedimento iterativo, desde a manipulação de materiais concretos, passando por aplicações geométricas, até atingir o Cálculo Numérico, como um dos procedimentos iterativos na resolução de equações lineares. Uma das conclusões é que, embora não seja o referido método, em sua forma mais simples, nenhum substitutivo para a resolução algébrica simbólica e moderna de equações e de sistemas de equações, ele se constitui certamente em um precioso trampolim para iniciarmos o salto em direção a um estudo mais formalizado. Particularmente, o método da falsa posição revela-se uma utilíssima ferramenta pedagógica na Educação Matemática, principalmente quando vinculado às suas origens históricas, suas abordagens concretas iniciais e suas associações com a Geometria e a Geometria Analítica.This text is a historical perspective on the early algebraic approach that is usually applied to the elementary teaching of Arithmetic. By arguing that such an initial algebraic treatment contains several drawbacks for elementary education, the ‘false position method' is discussed and is presented as a viable alternative for such introductory teaching. By pointing out the historical roots of the method, the text tries to make clear several ways of visualising this iterative procedure. This is done by incorporating the use of manipulatives and geometrical applications as well as the use of numerical calculus as an iterative

  16. Schwannoma of the adrenal gland

    Directory of Open Access Journals (Sweden)

    Anunayi Jeshtadi

    2014-07-01

    Full Text Available Visceral schwannomas are extremely rare and are usually discov-ered incidentally on USG/CT-Scan. Primary schwannomas of the adrenal gland are extremely uncommon. It has been theorized that they originate from Schwann cells that insulate the nerve fi-bers innervating the adrenal medulla. Histopathological examina-tion coupled with immunohistochemistry provides the definitive diagnosis. A 55 year old normotensive female presented with pain in the right loin since 5 months. Her renal parameters were normal. Contrast enhanced computed tomography of abdomen showed a well delineated 6.5 x 5cms mass at upper pole of her right kidney. 24-hour urinary metanephrine was slightly elevated (3.07mg/24hrs. A decline in Serum cortisol levels was observed following a dexamethasone suppression test (18.89nmol/l. Histopathological examination revealed a spindle cell tumor. Immunohistochemistry showed strong and diffuse positive staining for S-100 with negative expression for CD-117, desmin, CD-34, HMB-45, synaptophysin, chromogranin, cytokeratin, and SMA. Ki-67 index was 2%.A diagnosis of cellular schwannoma of adrenal gland was confirmed.

  17. False memories and confabulation.

    Science.gov (United States)

    Johnson, M K; Raye, C L

    1998-04-01

    Memory distortions range from the benign (thinking you mailed a check that you only thought about mailing), to the serious (confusing what you heard after a crime with what you actually saw), to the fantastic (claiming you piloted a spaceship). We review theoretical ideas and empirical evidence about the source monitoring processes underlying both true and false memories. Neuropsychological studies show that certain forms of brain damage (such as combined frontal and medial-temporal lesions) might result in profound source confusions, called confabulations. Neuroimaging techniques provide new evidence regarding more specific links between underlying brain mechanisms and the normal cognitive processes involved in evaluating memories. One hypothesis is that the right prefrontal cortex (PFC) subserves heuristic judgments based on easily assessed qualities (such as familiarity or perceptual detail) and the left PFC (or the right and left PFC together) subserves more systematic judgments requiring more careful analysis of memorial qualities or retrieval and evaluation of additional supporting or disconfirming information. Such heuristic and systematic processes can be disrupted not only by brain damage but also, for example, by hypnosis, social demands and motivational factors, suggesting caution in the methods used by `memory exploring' professions (therapists, police officers, lawyers, etc.) in order to avoid inducing false memories.

  18. Tumors of the sublingual gland

    DEFF Research Database (Denmark)

    Andreasen, Simon; Bjørndal, K; Agander, T K

    2016-01-01

    Tumors of the salivary glands are a heterogeneous group of diseases most often originating in the major salivary glands. Only a minor proportion of mainly malignant tumors arise in the sublingual gland. Due to the rarity of sublingual gland tumors (SGTs), little is known about the clinicopathologic...... are malignant, most frequently ACC with a high rate of metastatic spread. The diagnostic value of FNAC in SGTs seems inferior to what is found for other major salivary glands. DSS is determined by stage and T-stage and not by histopathological parameters. International collaboration is warranted to confirm...

  19. The impact of FNAC in the management of salivary gland lesions: Institutional experiences leading to a risk-based classification scheme.

    Science.gov (United States)

    Rossi, Esther Diana; Wong, Lawrence Q; Bizzarro, Tommaso; Petrone, Gianluigi; Mule, Antonio; Fadda, Guido; Baloch, Zubair M

    2016-06-01

    Fine-needle aspiration cytology (FNAC) has proven its value as an essential step in the diagnosis of salivary gland lesions. Although the majority of salivary gland lesions, especially those that are common and benign, can be diagnosed with ease on FNAC, limited cellularity and morphologic lesion heterogeneity can pose diagnostic challenges and lead to false-positive and false-negative diagnoses. This study presents the institutional experience of FNAC of salivary gland lesions from 2 academic centers. A retrospective analysis was conducted on 1729 salivary gland FNAC specimens that were diagnosed over an 8-year period from January 2008 to March 2015. All samples were processed either with liquid-based cytology alone or in combination with air-dried, Diff-Quik-stained or alcohol-fixed, Papanicolaou-stained smears. Surgical excision was performed in 709 of 1749 FNACs (41%) that were diagnosed as nondiagnostic/inadequate (n = 29), benign (n = 111), neoplasm (n = 453), atypical (n = 15), suspicious for malignancy (n = 28), and malignant (n = 73). The overall concordance between cytologic and histologic diagnoses was 92.2%, with 91.8% concordance in the benign category and 89.5% concordance in cases diagnosed as suspicious for malignancy and malignant. The most frequent benign and malignant lesions were pleomorphic adenoma and squamous cell carcinoma, respectively. There were 46 false-negative and 13 false-positive results, leading to an overall specificity of 97.6% and diagnostic accuracy of 91.3%. FNAC is a reliable diagnostic modality for the diagnosis and management of salivary gland lesions based on its high specificity and diagnostic accuracy. Cancer Cytopathol 2016;124:388-96. © 2016 American Cancer Society. © 2016 American Cancer Society.

  20. False color viewing device

    International Nuclear Information System (INIS)

    Kronberg, J.W.

    1992-01-01

    A viewing device for observing objects in near-infrared false-color comprising a pair of goggles with one or more filters in the apertures, and pads that engage the face for blocking stray light from the sides so that all light reaching the user's eyes come through the filters. The filters attenuate most visible light and pass near-infrared (having wavelengths longer than approximately 700 nm) and a small amount of blue-green and blue-violet (having wavelengths in the 500 to 520 nm and shorter than 435 nm, respectively). The goggles are useful for looking at vegetation to identify different species and for determining the health of the vegetation, and to detect some forms of camouflage. 7 figs

  1. False positive reaction due to endogenous biotin activity in glandular epithelium of decidua Reação falso positiva em epitélio glandular da decídua devido a atividade endógena de biotina

    Directory of Open Access Journals (Sweden)

    Liliana Cruz Spano

    2005-06-01

    Full Text Available Biotin-labeled probe was used in an in situ hybridisation assay to localize virus infection in formalin-fixed, paraffin embedded tissues taken from eleven abortion cases. Probes for human cytomegalovirus (HCMV, human Parvovirus B19 (B19 and human adenovirus type 2 (HAd2, were labeled with biotin-11-dUTP by nick-translation reaction. Streptavidin-alkaline-phosphatase (SAP was used to detect biotin, followed by 4-nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP solution. Positive reaction was observed in nucleus of glandular ephitelium cells of decidua either in positive or in negative control at first and second gestational trimester. The reaction was not inhibited with blocking solution for alkaline phosphatase endogenous activity and it persisted even with probes omission. The use of adequate negative control permitted to reveal the presence of nuclear biotin in glandular epithelium of decidua, responsible for false positivity in detection systems involving streptavidin biotin system (StrepABC. The stained cells resembled to cytophatic effect due to herpesvirus, which could induce further misinterpretation. The results obtained in this study strongly recommend that DNA detection by in situ hybridisation reaction in gestational endometrium should be done without using StrepABC system.Sondas marcadas com biotina foram utilizadas neste trabalho para detecção de infecção viral por hibridização in situ em tecidos fixados com formalina e embebidos em parafina de 11 casos obtidos de abortamento. Sondas para citomegalovírus humano (HCMV, parvovírus B19 humano (B19 e adenovírus humano tipo 2 (HAd2, foram marcadas com biotina-11-dUTP através da reação de nick-translation. Estreptavidina conjugada com fosfatase alcalina (SAP seguida por solução de 4-nitro-azul de tetrazolio/5-bromo-4-cloro-3-indolil fosfato (NBT/BCIP foram utilizadas para detecção da biotina após a reação de hibridização. Reação positiva foi

  2. Pituitary gland tumors

    International Nuclear Information System (INIS)

    Jesser, J.; Schlamp, K.; Bendszus, M.

    2014-01-01

    This article gives an overview of the most common tumors of the pituitary gland and the differential diagnostics with special emphasis on radiological diagnostic criteria. A selective search of the literature in PubMed was carried out. Pituitary adenomas constitute 10-15 % of all intracranial tumors and are the most common tumors of the sellar region. Tumors smaller than 1 cm in diameter are called microadenomas while those larger than 1 cm in diameter are called macroadenomas. Approximately 65 % of pituitary gland adenomas secrete hormones whereby approximately 50 % secrete prolactin, 10 % secrete growth hormone (somatotropin) and 6 % secrete corticotropin. Other tumors located in the sella turcica can also cause endocrinological symptoms, such as an oversecretion of pituitary hormone or pituitary insufficiency by impinging on the pituitary gland or its stalk. When tumors spread into the space cranial to the sella turcica, they can impinge on the optic chiasm and cause visual disorders. A common differential diagnosis of a sellar tumor is a craniopharyngeoma. In children up to 10 % of all intracranial tumors are craniopharyngeomas. Other differential diagnoses for sellar tumors are metastases, meningiomas, epidermoids and in rare cases astrocytomas, germinomas or Rathke cleft cysts As these tumors are located in an anatomically complex region of the skull base and are often very small, a highly focused imaging protocol is required. The currently favored modality is magnetic resonance imaging (MRI) with the administration of a contrast agent. The sellar region should be mapped in thin slices. In cases of suspected microadenoma the imaging protocol should also contain a sequence with dynamic contrast administration in order to assess the specific enhancement characteristics of the tumor and the pituitary gland. (orig.) [de

  3. [Pituitary gland tumors].

    Science.gov (United States)

    Jesser, J; Schlamp, K; Bendszus, M

    2014-10-01

    This article gives an overview of the most common tumors of the pituitary gland and the differential diagnostics with special emphasis on radiological diagnostic criteria. A selective search of the literature in PubMed was carried out. Pituitary adenomas constitute 10-15% of all intracranial tumors and are the most common tumors of the sellar region. Tumors smaller than 1 cm in diameter are called microadenomas while those larger than 1 cm in diameter are called macroadenomas. Approximately 65% of pituitary gland adenomas secrete hormones whereby approximately 50% secrete prolactin, 10% secrete growth hormone (somatotropin) and 6% secrete corticotropin. Other tumors located in the sella turcica can also cause endocrinological symptoms, such as an oversecretion of pituitary hormone or pituitary insufficiency by impinging on the pituitary gland or its stalk. When tumors spread into the space cranial to the sella turcica, they can impinge on the optic chiasm and cause visual disorders. A common differential diagnosis of a sellar tumor is a craniopharyngeoma. In children up to 10% of all intracranial tumors are craniopharyngeomas. Other differential diagnoses for sellar tumors are metastases, meningiomas, epidermoids and in rare cases astrocytomas, germinomas or Rathke cleft cysts As these tumors are located in an anatomically complex region of the skull base and are often very small, a highly focused imaging protocol is required. The currently favored modality is magnetic resonance imaging (MRI) with the administration of a contrast agent. The sellar region should be mapped in thin slices. In cases of suspected microadenoma the imaging protocol should also contain a sequence with dynamic contrast administration in order to assess the specific enhancement characteristics of the tumor and the pituitary gland.

  4. A very low geno2pheno false positive rate is associated with poor viro-immunological response in drug-naïve patients starting a first-line HAART.

    Science.gov (United States)

    Armenia, Daniele; Soulie, Cathia; Di Carlo, Domenico; Fabeni, Lavinia; Gori, Caterina; Forbici, Federica; Svicher, Valentina; Bertoli, Ada; Sarmati, Loredana; Giuliani, Massimo; Latini, Alessandra; Boumis, Evangelo; Zaccarelli, Mauro; Bellagamba, Rita; Andreoni, Massimo; Marcelin, Anne-Geneviève; Calvez, Vincent; Antinori, Andrea; Ceccherini-Silberstein, Francesca; Perno, Carlo-Federico; Santoro, Maria Mercedes

    2014-01-01

    We previously found that a very low geno2pheno false positive rate (FPR ≤ 2%) defines a viral population associated with low CD4 cell count and the highest amount of X4-quasispecies. In this study, we aimed at evaluating whether FPR ≤ 2% might impact on the viro-immunological response in HIV-1 infected patients starting a first-line HAART. The analysis was performed on 305 HIV-1 B subtype infected drug-naïve patients who started their first-line HAART. Baseline FPR (%) values were stratified according to the following ranges: ≤ 2; 2-5; 5-10; 10-20; 20-60; >60. The impact of genotypically-inferred tropism on the time to achieve immunological reconstitution (a CD4 cell count gain from HAART initiation ≥ 150 cells/mm(3)) and on the time to achieve virological success (the first HIV-RNA measurement immunological reconstitution was overall 75.5%, and it was significantly lower for FPR ≤ 2 (54.1%) in comparison to other FPR ranks (78.8%, FPR 2-5; 77.5%, FPR 5-10; 71.7%, FPR 10-20; 81.8%, FPR 20-60; 75.1%, FPR >60; p = 0.008). The overall proportion of patients achieving virological success was 95.5% by 12 months of therapy. Multivariable Cox analyses showed that patients having pre-HAART FPR ≤ 2% had a significant lower relative adjusted hazard [95% C.I.] both to achieve immunological reconstitution (0.37 [0.20-0.71], p = 0.003) and to achieve virological success (0.50 [0.26-0.94], p = 0.031) than those with pre-HAART FPR >60%. Beyond the genotypically-inferred tropism determination, FPR ≤ 2% predicts both a poor immunological reconstitution and a lower virological response in drug-naïve patients who started their first-line therapy. This parameter could be useful to identify patients potentially with less chance of achieving adequate immunological reconstitution and virological undetectability.

  5. Diagnostic Accuracy and Pitfalls of Preoperative Fine Needle Aspiration Cytology in Salivary Gland Lesions

    International Nuclear Information System (INIS)

    TAHOUN, N.; EZZAT, N.

    2008-01-01

    Purpose: Evaluation of diagnostic accuracy of preoperative fine needle aspiration cytology (FNAC) in salivary gland lesions. Patients and Methods: This is a retrospective study of 82 patients presented at NCI, Cairo University with salivary gland lesion who underwent preoperative FNAC diagnosis with subsequent excision and histopathologic assessment. Cytology results were classified as negative, positive, suspicious for cancer and inadequate. The definitive histopathologic report according to WHO Histological typing was the gold standard diagnosis against which FNAC was compared. Results: Our study included 82 patients who underwent preoperative FNAC of major salivary glands with subsequent surgical excision. Male to female ratio was 1.4: 1. The median age was 42 years. Parotid gland was involved in (68.3%), submandibular in (28%) and sub mental gland in (3.7%). Forty cases (48.8%) were cytologically diagnosed as benign lesions, 26 (31.7%) were malignant and 10 (12.2%) were suspicious. Cytological findings were non diagnostic in 6 (7.3%). The most common benign cytologic diagnosis was pleomorphic adenoma; 16 out of 40 cases (40%), while the most common malignant tumor was carcinoma; 22 out of 26 cases (84.6%). Cytologic diagnoses were compared with histopathologic ones and were true-negative in 37 (92.5%), true-positive in 33 (91.6%), false-negative in 3 (8.3%) and false-positive in 3 (7.5%) cases regarding detection of malignant tumors. The cytologic diagnosis achieved a sensitivity of 91.7%; a specificity of 92.5%, PPV 91.6%, NPV 92.5% and diagnostic accuracy 92%. The rates of agreement of histopathologic type for benign and malignant tumors were 89.2% and 91%, respectively. Conclusion: The sensitivity, specificity and diagnostic accuracy of FNAC were 91.7%, 92.5% and 92%, respectively. Attention to subtle morphologic changes, pitfalls and limitations are important to increase diagnostic accuracy. Multidirectional aspiration is preferred to avoid selective

  6. Magnetic resonance imaging validation of pituitary gland compression and distortion by typical sellar pathology.

    Science.gov (United States)

    Cho, Charles H; Barkhoudarian, Garni; Hsu, Liangge; Bi, Wenya Linda; Zamani, Amir A; Laws, Edward R

    2013-12-01

    Identification of the normal pituitary gland is an important component of presurgical planning, defining many aspects of the surgical approach and facilitating normal gland preservation. Magnetic resonance imaging is a proven imaging modality for optimal soft-tissue contrast discrimination in the brain. This study is designed to validate the accuracy of localization of the normal pituitary gland with MRI in a cohort of surgical patients with pituitary mass lesions, and to evaluate for correlation between presurgical pituitary hormone values and pituitary gland characteristics on neuroimaging. Fifty-eight consecutive patients with pituitary mass lesions were included in the study. Anterior pituitary hormone levels were measured preoperatively in all patients. Video recordings from the endoscopic or microscopic surgical procedures were available for evaluation in 47 cases. Intraoperative identification of the normal gland was possible in 43 of 58 cases. Retrospective MR images were reviewed in a blinded fashion for the 43 cases, emphasizing the position of the normal gland and the extent of compression and displacement by the lesion. There was excellent agreement between imaging and surgery in 84% of the cases for normal gland localization, and in 70% for compression or noncompression of the normal gland. There was no consistent correlation between preoperative pituitary dysfunction and pituitary gland localization on imaging, gland identification during surgery, or pituitary gland compression. Magnetic resonance imaging proved to be accurate in identifying the normal gland in patients with pituitary mass lesions, and was useful for preoperative surgical planning.

  7. Detection and localization of enlarged parathyroid glands in patients with hyperparathyroidism using 99mTc-methoxyisobutylisonitrile (MIBI). A study of subtraction scintigraphy with 99mTc-pertechnetate

    International Nuclear Information System (INIS)

    Katagiri, Makoto; Ohtawa, Takahiro; Otsuka, Nobuaki; Morita, Koichi; Sone, Teruki; Mimura, Hiroaki; Yanagimoto, Shinichi; Fukunaga, Masao; Harada, Tanekazu

    1995-01-01

    In this study we investigated the detectability of abnormal parathyroid gland(s) by 99m Tc-methoxy-isobutylisonitrile (MIBI) scintigraphy in patients with hyperparathyroidism. The subjects were 6 patients with primary hyperparathyroidism (PHP) with a single adenoma and 13 patients with renal hyperparathyroidism (RHP) on chronic maintenance hemodialysis. The imaging data of 99m Tc-pertechnetate were subtracted from those of 99m Tc-MIBI (MIBI-Tc), and number and location of the positive images on scintigrams were compared with those obtained by conventional scintigraphy using 201 Tl-Cl and 99m Tc-pertechnetate (Tl-Tc). All of the patients underwent surgery, and the number and location of the abnormal parathyroid glands were confirmed. The number of resected parathyroid glands were 6 in PHP and 52 in RHP. The detectability of MIBI-Tc was 83.3% in PHP and 51.9% in RHP, while that of Tl-Tc was 100% and 44.2%, respectively. Although no statistically significant difference in the detectability was found between MIBI-Tc and Tl-Tc, the number of false positives with MIBI-Tc was less than that with Tl-Tc. The detectability of MIBI-Tc depended on the size of the parathyroid gland. The maximal diameter and weight of the smallest parathyroid gland detected were 15 mm and 290 mg in PHP, and 9 mm and 50 mg in RHP. The existence of the thyroid gland did not reduce the detectability of MIBI-Tc. In conclusion, MIBI-Tc was clinically very useful for the detection of abnormal parathyroid glands in patients with hyperparathyroidism. (author)

  8. Emotions and false memories: valence or arousal?

    Science.gov (United States)

    Corson, Yves; Verrier, Nadège

    2007-03-01

    The effects of mood on false memories have not been studied systematically until recently. Some results seem to indicate that negative mood may reduce false recall and thus suggest an influence of emotional valence on false memory. The present research tested the effects of both valence and arousal on recall and recognition and indicates that the effect is actually due to arousal. In fact, whether participants' mood is positive, negative, or neutral, false memories are significantly more frequent under conditions of high arousal than under conditions of low arousal.

  9. How does negative emotion cause false memories?

    Science.gov (United States)

    Brainerd, C J; Stein, L M; Silveira, R A; Rohenkohl, G; Reyna, V F

    2008-09-01

    Remembering negative events can stimulate high levels of false memory, relative to remembering neutral events. In experiments in which the emotional valence of encoded materials was manipulated with their arousal levels controlled, valence produced a continuum of memory falsification. Falsification was highest for negative materials, intermediate for neutral materials, and lowest for positive materials. Conjoint-recognition analysis produced a simple process-level explanation: As one progresses from positive to neutral to negative valence, false memory increases because (a) the perceived meaning resemblance between false and true items increases and (b) subjects are less able to use verbatim memories of true items to suppress errors.

  10. Magnetic resonance imaging of normal pituitary gland

    International Nuclear Information System (INIS)

    Yamanaka, Masami; Uozumi, Tohru; Sakoda, Katsuaki; Ohta, Masahiro; Kagawa, Yoshihiro; Kajima, Toshio.

    1986-01-01

    Magnetic resonance imaging (MRI) is a suitable procedure for diagnosing such midline-positioned lesions as pituitary adenomas. To differentiate them from microadenomas fifty-seven cases (9 - 74 years old, 29 men and 28 women), including 50 patients without any sellar or parasellar diseases and seven normal volunteers, were studied in order to clarify the MR findings of the shape, height, and signal intensity of the normal pituitary gland, especially at the median sagittal section. The height of a normal pituitary gland varied from 2 to 9 mm (mean: 5.7 mm); the upper surface of the gland was convex in 19.3 %, flat in 49.1 %, and concave in 31.6 %. The mean height of the gland in women in their twenties was 7.5 mm, and the upper convex shape appeared exclusively in women of the second to fourth decades. Nine intrasellar pituitary adenomas (PRL-secreting: 4, GH-secreting: 4, ACTH-secreting: 1), all verified by surgery, were diagnosed using a resistive MR system. The heights of the gland in these cases were from 7 to 15 mm (mean: 11.3 mm); the upper surface was convex in 7 cases. A localized bulging of the upper surface of the gland and a localized depression of the sellar floor were depicted on the coronal and sagittal sections in most cases. Although the GH- and ACTH-secreting adenoma cases showed homogeneous intrasellar contents, in all the PRL-secreting adenoma cases a low-signal-intensity area was detected in the IR images. The mean T1 values of the intrasellar content of the normal volunteers, the PRL-, GH-, and ACTH-secreting adenoma cases, were 367, 416, 355, and 411 ms respectively. However, in the PRL-secreting adenoma cases, the mean T1 value of the areas showing a low signal intensity on IR images was 455 ms; this was a significant prolongation in comparison with that of a normal pituitary gland. (J.P.N.)

  11. Is 18F-fluorocholine-positron emission tomography/computerized tomography a new imaging tool for detecting hyperfunctioning parathyroid glands in primary or secondary hyperparathyroidism?

    Science.gov (United States)

    Michaud, Laure; Burgess, Alice; Huchet, Virginie; Lefèvre, Marine; Tassart, Marc; Ohnona, Jessica; Kerrou, Khaldoun; Balogova, Sona; Talbot, Jean-Noël; Périé, Sophie

    2014-12-01

    Preoperative ultrasonography and scintigraphy using (99m)Tc-sestamibi are commonly used to localize abnormal parathyroid glands. In cases of discrepant results between scintigraphy and ultrasonography, it is important to rely on another diagnostic imaging modality. (18)F-fluorodeoxyglucose (FDG) and (11)C-methionine positron emission tomography (PET) have been studied, but are imperfect to detect abnormal parathyroid glands. Recently, first cases of abnormal parathyroid glands taking-up radiolabelled choline were discovered incidentally in men referred to (11)C-choline or (18)F-fluorocholine (FCH)-PET/CT for prostate cancer. We checked if FCH uptake was a general feature of adenomatous or hyperplastic parathyroid glands. FCH-PET/CT was performed in 12 patients with primary (n = 8) or secondary hyperparathyroidism (1 dialyzed, 3 grafted) and with discordant or equivocal results on preoperative ultrasonography (US) and/or (123)I/(99m)Tc-sestamibi dual-phase scintigraphy. The results of the FCH-PET/CT were evaluated, with surgical exploration and histopathologic examination as the standard of truth. On a per-patient level, the detection rate of FCH-PET/CT (at least one FCH focus corresponding to an abnormal parathyroid gland in a given patient) was 11/12 = 92%. FCH-PET/CT detected 18 foci interpreted as parathyroid glands and correctly localized 17 abnormal parathyroid glands (7 adenomas and 10 hyperplasias). On a per-lesion level, FCH-PET/CT results were 17 TP, 2 false negative ie, a lesion-based sensitivity of 89%, and 1 false positive. As the main result of this pilot study, we show that in patients with hyperparathyroidism and with discordant or equivocal results on scintigraphy or on ultrasonography, adenomatous or hyperplastic parathyroid glands can be localized by FCH-PET/CT with good accuracy. Furthermore, FCH-PET/CT can solve discrepant results between preoperative ultrasonography and scintigraphy and has thus a potential as a functional imaging modality in

  12. The ectopic posterior pituitary gland

    African Journals Online (AJOL)

    2013-11-04

    Nov 4, 2013 ... crinology with short stature, delayed bone age and biochemical features suggestive of hypo pituitarism. Magnetic resonance imaging of the brain demonstrated a flattened anterior pituitary gland within the sella, associated with absence of the infundibular stalk and an ectopic posterior pituitary gland (Fig.

  13. False memories, but not false beliefs, affect implicit attitudes for food preferences.

    Science.gov (United States)

    Howe, David; Anderson, Rachel J; Dewhurst, Stephen A

    2017-09-01

    Previous studies have found that false memories and false beliefs of childhood experiences can have attitudinal consequences. Previous studies have, however, focused exclusively on explicit attitude measures without exploring whether implicit attitudes are similarly affected. Using a false feedback/imagination inflation paradigm, false memories and beliefs of enjoying a certain food as a child were elicited in participants, and their effects were assessed using both explicit attitude measures (self-report questionnaires) and implicit measures (a Single-Target Implicit Association Test). Positive changes in explicit attitudes were observed both in participants with false memories and participants with false beliefs. In contrast, only participants with false memories exhibited more positive implicit attitudes. The findings are discussed in terms of theories of explicit and implicit attitudes. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. The semantics of emotion in false memory.

    Science.gov (United States)

    Brainerd, C J; Bookbinder, S H

    2018-03-26

    The emotional valence of target information has been a centerpiece of recent false memory research, but in most experiments, it has been confounded with emotional arousal. We sought to clarify the results of such research by identifying a shared mathematical relation between valence and arousal ratings in commonly administered normed materials. That relation was then used to (a) decide whether arousal as well as valence influences false memory when they are confounded and to (b) determine whether semantic properties that are known to affect false memory covary with valence and arousal ratings. In Study 1, we identified a quadratic relation between valence and arousal ratings of words and pictures that has 2 key properties: Arousal increases more rapidly as function of negative valence than positive valence, and hence, a given level of negative valence is more arousing than the same level of positive valence. This quadratic function predicts that if arousal as well as valence affects false memory when they are confounded, false memory data must have certain fine-grained properties. In Study 2, those properties were absent from norming data for the Cornell-Cortland Emotional Word Lists, indicating that valence but not arousal affects false memory in those norms. In Study 3, we tested fuzzy-trace theory's explanation of that pattern: that valence ratings are positively related to semantic properties that are known to increase false memory, but arousal ratings are not. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  15. Factors of salivary gland tumor influence on salivary gland function. Studies on salivary scintigraphy using 99mTcO4-

    International Nuclear Information System (INIS)

    Toyama, Michio; Katada, Tsutomu; Sasaki, Yoshihiko; Togashi, Masatoshi; Tsuchimochi, Makoto

    2000-01-01

    The purpose of this study was to show clearly what factors such as tumor size, duration of illness, location, and tumor invasion in salivary gland tumor affect salivary gland function. The study cases were 42 salivary gland tumor patients who underwent computed tomography (CT) and sialoscintigraphy. Salivary gland tumor was confirmed histopathologically. The patients were 24 males and 18 females, aged from 16 to 82 years old (mean age: 52.8 years old). There were 23 patients with parotid gland tumors and 19 patients with submandibular gland tumors (27 benign tumors, 15 malignant tumors). By using 99m TcO 4 - sialoscintigraphy, the salivary gland function was classified into three different types according to stimulatory selection ratio which was expressed as the ratio of pre- to post-stimulation counts on the salivary gland, namely, normal, lower functional, and no functional types. Then the normal type was judged abnormal function, and the lower and no functional types were judged as abnormal function. The results were as follows: There was a significant difference between malignant tumor and benign tumor in salivary gland function (P<0.0001). Depending on tumor size, abnormal function was significantly higher than normal function (P<0.05). There was no statistical significant difference among duration of illness, location of tumor, and salivary gland function. There was a significant difference between tumor invasion and salivary gland function (P<0.0001). The results showed that salivary gland function was disturbed in salivary gland tumor with larger size and positive invasion. (author)

  16. Pituitary gland tumors; Hypophysentumoren

    Energy Technology Data Exchange (ETDEWEB)

    Jesser, J.; Schlamp, K.; Bendszus, M. [Radiologische Klinik, Universitaetsklinikum Heidelberg, Abteilung fuer Neuroradiologie, Heidelberg (Germany)

    2014-10-15

    This article gives an overview of the most common tumors of the pituitary gland and the differential diagnostics with special emphasis on radiological diagnostic criteria. A selective search of the literature in PubMed was carried out. Pituitary adenomas constitute 10-15 % of all intracranial tumors and are the most common tumors of the sellar region. Tumors smaller than 1 cm in diameter are called microadenomas while those larger than 1 cm in diameter are called macroadenomas. Approximately 65 % of pituitary gland adenomas secrete hormones whereby approximately 50 % secrete prolactin, 10 % secrete growth hormone (somatotropin) and 6 % secrete corticotropin. Other tumors located in the sella turcica can also cause endocrinological symptoms, such as an oversecretion of pituitary hormone or pituitary insufficiency by impinging on the pituitary gland or its stalk. When tumors spread into the space cranial to the sella turcica, they can impinge on the optic chiasm and cause visual disorders. A common differential diagnosis of a sellar tumor is a craniopharyngeoma. In children up to 10 % of all intracranial tumors are craniopharyngeomas. Other differential diagnoses for sellar tumors are metastases, meningiomas, epidermoids and in rare cases astrocytomas, germinomas or Rathke cleft cysts As these tumors are located in an anatomically complex region of the skull base and are often very small, a highly focused imaging protocol is required. The currently favored modality is magnetic resonance imaging (MRI) with the administration of a contrast agent. The sellar region should be mapped in thin slices. In cases of suspected microadenoma the imaging protocol should also contain a sequence with dynamic contrast administration in order to assess the specific enhancement characteristics of the tumor and the pituitary gland. (orig.) [German] Diese Arbeit ist eine Uebersicht ueber die haeufigsten Hypophysentumoren und deren Differenzialdiagnosen mit Augenmerk auf die

  17. Chapter 13. Adrenal glands

    International Nuclear Information System (INIS)

    Roux, H.; Paulin, R.

    1975-01-01

    The condition of isotopic methods to the functional and morphological exploration of the adrenal glands is shown, with emphasis on the fact that althought the cortico-adrenal responds to these methods the same does not apply to the medullo-adrenal, which expresses its morphological changes by producing deformations on the cortical image. Funtional tests, mainly directed at the cortico-adrenal, are described first: study of exchangeable sodium and potassium; determination of the plasma concentration and metabolic clearance of some steroid hormones (cortisol, corticosterone, aldosterone); evaluation of the renin activity. These tests are based on competitive analysis and radioimmunological methods. Morphological tests are examined next. Adrenal scintigraphy uses a simple technique (intraveinous administration of 131 I 19-iodocholesterol with no special preliminary preparation) which gives good images and is only limited now by the need to avoid over exposure of the gonads to ionising radiations [fr

  18. Cryopreservation of Parathyroid Glands

    Directory of Open Access Journals (Sweden)

    Marlon A. Guerrero

    2010-01-01

    Full Text Available The risk of permanent hypoparathyroidism following thyroid and parathyroid surgery is around 1% in the hands of experienced endocrine surgeons. Although this complication is rare, rendering a patient permanently aparathyroid has significant consequences on the health and quality of life of the patient. Immediate autotransplantation of parathyroid glands that are injured or unintentionally removed offers the best possibility of graft viability and functionality. However, since the majority of cases of hypoparathyroidism are transient, immediate autotransplantation can complicate postoperative surveillance in certain patients, especially those with primary hyperparathyroidism. Cryopreservation of parathyroid tissue is an alternate technique that was developed to treat patients with permanent hypoparathyroidism. This method allows for parathyroid tissue to be stored and then autotransplanted in a delayed fashion once permanent hypoparathyroidism is confirmed. This article provides a contemporary review on cryopreservation of parathyroid tissue and its current role in thyroid and parathyroid surgery.

  19. Geometric changes of parotid glands caused by hydration during chemoradiotherapy

    International Nuclear Information System (INIS)

    Kager, Petronella M.; Weerdenburg, Sanne C. C. van; Kranen, Simon R. van; Beek, Suzanne van; Lamers-Kuijper, Elisabeth A.; Heemsbergen, Wilma D.; Hamming-Vrieze, Olga; Remeijer, Peter

    2015-01-01

    Plan adaptation during the course of (chemo)radiotherapy of H&N cancer requires repeat CT scanning to capture anatomy changes such as parotid gland shrinkage. Hydration, applied to prevent nephrotoxicity from cisplatin, could temporarily alter the hydrogen balance and hence the captured anatomy. The aim of this study was to determine geometric changes of parotid glands as function of hydration during chemoradiotherapy compared to a control group treated with radiotherapy only. This study included an experimental group (n = 19) receiving chemoradiotherapy, and a control group (n = 19) receiving radiotherapy only. Chemoradiotherapy patients received cisplatin with 9 l of saline solution during hydration in the first, fourth and seventh week. The delineations of the parotid glands on the planning CT scan were automatically propagated to Cone Beam CT scans using deformable image registration. Relative volume and position of the parotid glands were determined at the second chemotherapy cycle (week four) and at fraction 35. When saline solution was administrated, the volume temporarily increased on the first day (7.2 %, p < 0.001), second day (10.8 %, p < 0.001) and third day (7.0 %, p = 0.016). The gland positions shifted lateral, the distance between glands increased on the first day with 1.5 mm (p < 0.001), on the second day 2.2 mm (p < 0.001). At fraction 35, with both groups the mean shrinkage was 24 % ± 11 % (1SD) and the mean medial distance between the parotid glands decreased by 0.47 cm ± 0.27 cm. Hydration significantly modulates parotid gland geometry. Unless, in the context of adaptive RT, a repeat CT scan is timed during a chemotherapy cycle, these effects are of minor clinical relevance

  20. False memories for aggressive acts.

    Science.gov (United States)

    Laney, Cara; Takarangi, Melanie K T

    2013-06-01

    Can people develop false memories for committing aggressive acts? How does this process compare to developing false memories for victimhood? In the current research we used a simple false feedback procedure to implant false memories for committing aggressive acts (causing a black eye or spreading malicious gossip) or for victimhood (receiving a black eye). We then compared these false memories to other subjects' true memories for equivalent events. False aggressive memories were all too easy to implant, particularly in the minds of individuals with a proclivity towards aggression. Once implanted, the false memories were indistinguishable from true memories for the same events, on several dimensions, including emotional content. Implications for aggression-related memory more generally as well as false confessions are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Fetal adrenal gland enlargement - prenatal and postnatal management.

    Science.gov (United States)

    Lackova, Eliska; Cunderlik, Anton; Ticha, Lubica; Gabor, Maria

    2017-11-01

    The enlargement of suprarenal gland is related to preterm birth and the birth weight. The ultrasound measurement of fetal adrenal gland volume may identify women at risk for impending preterm birth. The aim of our study was to investigate the newborns in the region of western Slovakia followed up due to suprarenal gland enlargement. To set the ratio of prenatally diagnosed suprarenal gland enlargment, postnatal managment and treatment and interventions. The newborns with congenital adrenal hyperplasia were excluded. We have analyzed 6 years of medical records of all cases from the western Slovakia region of suprarenal gland enlargement encountered to 1st Pediatric Department, Children's University Hospital Bratislava Republic in the time period of January 2010 to Janurary 2016. The diagnosis of suprarenal gland enlargement was set by ultrasound examination performed on the 4th postnatal day as an overall screening test. Newborns with positive laboratory screening on congenital adrenal hyperplasia (CAH) were excluded from our study. We analyzed the origin of surarenal gland enlargement, gestation week on the due date, the birth weight and other comorbidities and genetic pathologies in newborns with the enlarged suprarenal glands. There were 6 newborns followed up due to suprarenal gland enlargement. All of the patients had diagnosed the adrenal haemorrhage. Adrenal lesions like adrenal cysts or neuroblastomas were not confirmed. All of the adrenal enlargements were benign with no need of other medical or surgical intervention. None of the newborn patients had other genetic abnormalities, mineral or hormonal imbalances, problems with arterial pressure or haemodynamic instability. All of the patients underwent at least 5 prenatal ultrasound tests and at least 2 postnatal ultrasound measurements. The avarage birth weight was 3030 grams (2700 grams - to 3750 grams). The avarage birth lenght was 50 cm (47 centimeter to 53 cm).The average gestation week (gw) on due date

  2. Prostate malignancy grading using gland-related shape descriptors

    Science.gov (United States)

    Braumann, Ulf-Dietrich; Scheibe, Patrick; Loeffler, Markus; Kristiansen, Glen; Wernert, Nicolas

    2014-03-01

    A proof-of-principle study was accomplished assessing the descriptive potential of two simple geometric measures (shape descriptors) applied to sets of segmented glands within images of 125 prostate cancer tissue sections. Respective measures addressing glandular shapes were (i) inverse solidity and (ii) inverse compactness. Using a classifier based on logistic regression, Gleason grades 3 and 4/5 could be differentiated with an accuracy of approx. 95%. Results suggest not only good discriminatory properties, but also robustness against gland segmentation variations. False classifications in part were caused by inadvertent Gleason grade assignments, as a-posteriori re-inspections had turned out.

  3. [Immunoendocrine associations in adrenal glands].

    Science.gov (United States)

    Sterzl, I; Hrdá, P

    2010-12-01

    Immune and endocrine systems are basic regulatory mechanisms of organism and, including the nervous system, maintain the organism's homeostasis. The main immune system representatives are mononuclear cells, T- and B-cells and their products, in the endocrine system the main representatives are cells of the glands with inner secretion and their products. One of the most important glands for maintaining homeostasis are adrenal glands. It has been proven that either cells of the immune system, either endocrine cells can, although in trace amounts, produce mutually mediators of both systems (hormones, cytokines). Disorders in one system can lead to pathological symptoms in the other system. Also here represent adrenals an important model.

  4. Uneven Meibomian Gland Dropout Over the Tarsal Plate and its Correlation With Meibomian Gland Dysfunction.

    Science.gov (United States)

    Yin, Yue; Gong, Lan

    2015-10-01

    To evaluate the distribution of meibomian gland dropout and analyze the correlation between dropout and meibomian gland dysfunction (MGD). A total of 161 eyes of 85 patients with MGD were recruited as the MGD group; 88 eyes of 46 health volunteers were enrolled as the control group (2:1 matched for age and sex). Examinations included the Schirmer I test, breakup time, symptom questionnaire, corneal fluorescein staining, meibum quality, meibomian gland expressibility, and meibomian gland dropout. (1) The incidences of chalazion and eyelid surgery were significantly higher in patients with MGD. (2) All clinical indexes were better in healthy volunteers (all P dropout in the upper eyelid was statistically lower (P dropout than did the middle part, except in the lower eyelid of the control group. (4) The entire or partial dropout was positively related to MGD occurrence. Both additive dropout of the entire 2 eyelids and that of the 2 nasal parts had the strongest correlation (r = 0.792, P dropout (r = -0.229, P dropout of additive (r = 0.185, P dropouts exist in different or single eyelids. (2) Dropout evaluation is better when covering the entire area of both upper and lower meibomians. (3) Nasal part dropout plays a more essential role than the other dropouts in MGD occurrence.

  5. False positive diagnosis of malignancy in a case of cryptogenic organising pneumonia presenting as a pulmonary mass with mediastinal nodes detected on fluorodeoxyglucose-positron emission tomography: a case report

    Science.gov (United States)

    2009-01-01

    Introduction We report the case of a patient with positive findings on a lung emission tomography/computed tomography (PET/CT) scan, with possible contra lateral mediastinal involvement, which strongly suggested an inoperable lung carcinoma. The lung mass proved to be a cryptogenic organising pneumonia. While the latter has previously been shown to be PET/CT positive, mediastinal involvement simulating malignant spread has not been previously reported. Case presentation A 50-year-old Caucasian woman presented with a history of unproductive cough and was found to have a mass in the right upper lobe as shown on chest X-ray and a computed tomography scan. A subsequent PET/CT scan showed strong uptake in the right upper lobe (maximum standard uptake values (SUVmax) 9.6) with increased uptake in the adjacent mediastinum and contralateral mediastinal nodes. Surgical resection and mediastinoscopy revealed cryptogenic organising pneumonia, with enlarged reactive mediastinal lymph nodes. Conclusion The case illustrates the limits of PET/CT scanning as a diagnostic tool, and emphasizes the importance of obtaining histological confirmation of malignant diseases whenever possible. PMID:19946541

  6. Intrasellar Symptomatic Salivary Gland Rest

    Directory of Open Access Journals (Sweden)

    Chih-Hao Chen

    2007-05-01

    Full Text Available Ectopic salivary gland tissue in sellar turcica is frequently observed in microscopic examination at autopsy. This tissue is considered clinically silent. Only 2 symptomatic cases have been previously reported. Here we report a 28-year-old woman presenting with galactorrhea and hyperprolactinemia. Magnetic resonance imaging revealed a 6×5-mm nodule in the posterior aspect of the pituitary gland. This nodule showed isointensity on T1- and T2-weighted images and less enhancement on post-contrast T1-weighted images. Transsphenoidal exploration revealed a cystic lesion within the pituitary gland, which consisted of a grayish gelatinous content. The pathologic examination confirmed the diagnosis of salivary gland rest.

  7. Myositis ossificans: a false positive of malignancy in PET - CT F.D.G. and in osseous scintigraphy with HMDP {sup 99}Tc;La myosite ossifiante: un faux positif de malignite en TEP-TDM FDG et en scintigraphie osseuse au HMDP Tc99

    Energy Technology Data Exchange (ETDEWEB)

    Hassler, S.; Bourahla, K. [CLCC Paul-Strauss, Service de medecine nucleaire, 67 - Strasbourg (France)

    2010-05-15

    Myositis ossificans is a difficult differential diagnosis and a false positive for malignancy in both {sup 99m}Tc H.M.D.P. (hydroxy-methylene diphosphonate) scintigraphy and in exploration PET-F.D.G. This hypothesis should be mentioned in case of young patients, despite the unusual scintigraphic appearance in a benign process. (N.C.)

  8. Multidisciplinary team review of best practices for collection and handling of blood cultures to determine effective interventions for increasing the yield of true-positive bacteremias, reducing contamination, and eliminating false-positive central line-associated bloodstream infections.

    Science.gov (United States)

    Garcia, Robert A; Spitzer, Eric D; Beaudry, Josephine; Beck, Cindy; Diblasi, Regina; Gilleeny-Blabac, Michelle; Haugaard, Carol; Heuschneider, Stacy; Kranz, Barbara P; McLean, Karen; Morales, Katherine L; Owens, Susan; Paciella, Mary E; Torregrosa, Edwin

    2015-11-01

    A literature search was conducted using keywords for articles published in English from January 1990 to March 2015. Using criteria related to blood culture collection and handling, the search yielded 101 articles. References used also included Microbiology Laboratory standards, guidelines, and textbook information. The literature identified diverse and complex issues surrounding blood culture practices, including the impact of false-positive results, laboratory definition of contamination, effect on central line-associated bloodstream infection (CLABSI) reporting, indications for collecting blood cultures, drawing from venipuncture sites versus intravascular catheters, selection of antiseptics, use of needleless connectors, inoculation of blood culture bottles, and optimizing program management in emergency departments, education, and implementation of bundled practice initiatives. Hospitals should optimize best practice in the collection, handling, and management of blood culture specimens, an often overlooked but essential component in providing optimal care of patients in all settings and populations, reducing financial burdens, and increasing the accuracy of reportable CLABSI. Although universal concepts exist in blood culture practices, some issues require further research to determine benefit. Institutions undertaking a review of their blood culture programs are encouraged to use a checklist that addresses elements that encompass the research contained in this review. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Localization diagnosis of hyperfunctional parathyroid gland using 99Tcm-MIBI and 99TcmO4- imaging

    International Nuclear Information System (INIS)

    Zhang Fenru; Deng Huixing; Duan Xiaoyi; Xue Jianjun; Gao Rui

    2010-01-01

    Objective: To study the localization diagnosis value of nuclide imaging by 99 Tc m -MIBI double phase parathyroid combined with 99 Tc m O 4 - thyroid imaging in patients with hyperparathyroidism (HPT). Methods: Patients with primary HPT were 36 cases. Control groups were 10 cases with thyroid disease. Early phase imaging was performed in 15 minute after injecting imaging agent 99 Tc m -MIBI. Delay phase imaging was performed in 2 hours. 36 HPT patients and 10 cases control groups were also performed 99 Tc m O 4 - thyroid imaging 24 hours later. The two kinds of imaging were compared with each other, were analyzed, and were underwent imaging subtracted by eyes and imaging results judgment. Results: In 36 cases of HPT patients, 34 cases showed positive result imaging with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. 2 cases showed false negative result. Positive rate was 94.44 % with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. The positive result imaging showed abnormal increased uptake of 99 Tc m -MIBI. In 36 cases of HPT patients, 12 cases showed positive result with single 99 Tc m -MIBI imaging. 4 cases showed false negative imaging. 20 cases showed ambiguous positive results. Positive rate was 88.89% (55.56% was ambiguous positive results) with single 99 Tc m -MIBI imaging. In 10 cases control groups, 3 cases showed false positive results with single 99 Tc m -MIBI imaging. 1 case showed ambiguous false positive results. No case showed false positive result with 99 Tc m -MIBI/ 99 Tc m O 4 - imaging. Conclusion: 99 Tc m -MIBI parathyroid double phase imaging combined with 99 Tc m O 4 - thyroid imaging have important value for diagnoses and localization of hyperparathyroidism. 99 Tc m -MIBI/ 99 Tc m O 4 - imaging have higher positive rate and higher specificity than single 99 Tc m -MIBI imaging for diagnoses and localization of hyperfunction parathyroid gland. (authors)

  10. False Memories for Affective Information in Schizophrenia.

    Science.gov (United States)

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls ( p  false memories ( p  > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  11. False Memories for Affective Information in Schizophrenia

    Science.gov (United States)

    Fairfield, Beth; Altamura, Mario; Padalino, Flavia A.; Balzotti, Angela; Di Domenico, Alberto; Mammarella, Nicola

    2016-01-01

    Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the to-be-remembered material and false memory occurrence has not yet been studied. In this study, 24 patients and 24 healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative, or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p false memories (p > 0.05) resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e., neutral episodes yielded a higher degree of errors than positive and negative episodes). Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved. PMID:27965600

  12. The influence of the noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) resection diagnosis on the false-positive thyroid cytology rate relates to quality assurance thresholds and the application of NIFTP criteria.

    Science.gov (United States)

    Ohori, N Paul; Wolfe, Jenna; Carty, Sally E; Yip, Linwah; LeBeau, Shane O; Berg, Aaron N; Schoedel, Karen E; Nikiforov, Yuri E; Seethala, Raja R

    2017-09-01

    Noninvasive follicular thyroid neoplasm with papillary-like nuclear features (NIFTP) is a newly defined entity and recent studies have suggested a decrease of a few percentage points in the rate of malignancy (ROM) for the positive-for-malignancy (PFM) cytology category as a result of NIFTP implementation. However, the distinction between a diagnosis of PFM and one of suspicious for malignancy (SFM) may depend on a variety of factors. In the current study, the authors investigated the ROM for the PFM and SFM diagnoses before and after histologic NIFTP reclassification. Cytology cases with PFM and SFM diagnoses and subsequent surgical resection specimens were searched in the files of the study institution from September 2008 to September 2016. The surgical pathology cases of noninvasive encapsulated follicular variant of papillary thyroid carcinoma were reexamined to determine whether they qualified for NIFTP. The distinct ROMs for the PFM and SFM cases were calculated accordingly. The authors' search identified 338 cases of PFM and 139 cases of SFM with a resection outcome. Before NIFTP reclassification, the PFM cases had a ROM of 99.4%; after NIFTP reclassification, the ROM was 99.1% (P = .6861). The ROM of the SFM cases decreased from 75.5% to 66.9% with NIFTP reclassification (P = .1402). One case in the PFM group and 6 cases in the SFM group could not be verified due to insufficient sampling. In the current large series, NIFTP reclassification did not appear to significantly alter the high ROM for the PFM diagnosis. The authors attribute this finding to a strict quality assurance policy, an emphasis on key cytologic criteria, and systematic application of the NIFTP criteria to follicular-patterned lesions. Cancer Cytopathol 2017;125:692-700. © 2017 American Cancer Society. © 2017 American Cancer Society.

  13. Reduced False Memory after Sleep

    Science.gov (United States)

    Fenn, Kimberly M.; Gallo, David A.; Margoliash, Daniel; Roediger, Henry L., III; Nusbaum, Howard C.

    2009-01-01

    Several studies have shown that sleep contributes to the successful maintenance of previously encoded information. This research has focused exclusively on memory for studied events, as opposed to false memories. Here we report three experiments showing that sleep reduces false memories in the Deese-Roediger-McDermott (DRM) memory illusion. False…

  14. Streaming submandibular gland

    International Nuclear Information System (INIS)

    Zajicek, G.; Yagil, C.; Michaeli, Y.

    1985-01-01

    Twenty female young adult rats were injected with tritiated thymidine ( 3 HTdR). The animals were then killed in groups of five, at the following times: 1 hour, and 4, 16, and 23 days. Autoradiograms of sections through the submandibular gland were prepared, and the location of labelled cells in relationship to tubuli and acini was recorded. The different tubular and acinar cross sections could be distinguished by their cell number. Narrow tubuli had fewer nuclei than the wider ones. The nuclear number of a cross section was defined as its class and the location of a labelled epithelial cell was expressed in relationship to the class where it was found. The location of a labelled stromal cell was determined by the class of its neighboring tubular or acinar cross sections. The mean cell numbers of intercalated, granular, and striated duct cross sections were, respectively, 4.7, 10.5, and 10.2, while the average cell content of acini was 4.7 cells. One hour after labelling most labelled tubular epithelial and stromal cells were found in tubular cross sections (or low tubular classes), while in the acini, labelled epithelial and stromal cells were found mainly in wider cross sections (or higher acinar classes). Within the next 23 days labelled tubular cells and stroma proceeded into higher classes, while labelled acinar epithelium and stroma cells were displaced into narrower cross sections (or lower classes). The displaced tubular epithelium and stroma covered daily 0.26 classes. At this velocity the cell will reach the highest tubular class in 62 days and the estimated maximal tubular cell life span is 62 days

  15. Microbiology of Bartholin's Gland Abscess in Japan

    Science.gov (United States)

    Tanaka, Kaori; Mikamo, Hiroshige; Ninomiya, Mochiyoshi; Tamaya, Teruhiko; Izumi, Koji; Ito, Kunihiko; Yamaoka, Kazukiyo; Watanabe, Kunitomo

    2005-01-01

    This study was conducted to determine the current epidemiology concerning the causative organisms for Bartholin's gland abscess in Japan. Microbiological examination of 224 cases showed positive results in 219 cases and negative results in 5 cases. Of all of the bacterial isolates, 307 and 118 were aerobes and anaerobes, respectively. The most frequently isolated bacterium was Escherichia coli. Of the anaerobes, the most frequently isolated organism was Bacteroides species, followed by Prevotella species. The organisms related to respiratory infectious diseases, such as Streptococcus pneumoniae and Haemophilus influenzae, including resistant bacteria, were sometimes involved between 2000 and 2004. PMID:16081994

  16. Unique thermal record in False Bay

    CSIR Research Space (South Africa)

    Grundlingh, ML

    1993-10-01

    Full Text Available Over the past decade False Bay has assumed a prime position in terms of research in to large South African bays. This is manifested by investigations that cover flow conditions modelling, thermal structure, management, biology and nutrients, geology...

  17. Distance Sensitive Bloom Filters Without False Negatives

    DEFF Research Database (Denmark)

    Goswami, Mayank; Pagh, Rasmus; Silvestri, Francesco

    2017-01-01

    A Bloom filter is a widely used data-structure for representing a set S and answering queries of the form “Is x in S?”. By allowing some false positive answers (saying ‘yes’ when the answer is in fact ‘no’) Bloom filters use space significantly below what is required for storing S. In the distanc...

  18. False memories for affective information in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Beth Fairfield

    2016-11-01

    Full Text Available Studies have shown a direct link between memory for emotionally salient experiences and false memories. In particular, emotionally arousing material of negative and positive valence enhanced reality monitoring compared to neutral material since emotional stimuli can be encoded with more contextual details and thereby facilitate the distinction between presented and imagined stimuli. Individuals with schizophrenia appear to be impaired in both reality monitoring and memory for emotional experiences. However, the relationship between the emotionality of the-to-be-remembered material and false memory occurrence has not yet been studied. In this study, twenty-four patients and twenty-four healthy adults completed a false memory task with everyday episodes composed of 12 photographs that depicted positive, negative or neutral outcomes. Results showed how patients with schizophrenia made a higher number of false memories than normal controls (p0.05 resulting from erroneous inferences but did interact with plausible, script consistent errors in patients (i.e. neutral episodes yielded a higher degree of errors than positive and negative episodes. Affective information reduces the probability of generating causal errors in healthy adults but not in patients suggesting that emotional memory impairments may contribute to deficits in reality monitoring in schizophrenia when affective information is involved.

  19. Skin glands, poison and mimicry in dendrobatid and leptodactylid amphibians.

    Science.gov (United States)

    Prates, Ivan; Antoniazzi, Marta M; Sciani, Juliana M; Pimenta, Daniel C; Toledo, Luís Felipe; Haddad, Célio F B; Jared, Carlos

    2012-03-01

    In amphibians, secretions of toxins from specialized skin poison glands play a central role in defense against predators. The production of toxic secretions is often associated with conspicuous color patterns that warn potential predators, as it is the case of many dendrobatid frogs, including Ameerega picta. This species resembles the presumably nontoxic Leptodactylus lineatus. This study tests for mimicry by studying the morphology and distribution of skin glands, components of skin secretion, and defensive behavior. Dorsal skin was studied histologically and histochemically, and skin secretions were submitted to sodium dodecyl sulfate polyacrylamide gel electrophoresis, reversed phase high performance liquid chromatography and assays for proteolytic activity. We found that poison glands in A. picta are filled with nonprotein granules that are rich in carbohydrates, while L. lineatus glands present protein granules. Accordingly, great amounts of proteins, at least some of them enzymes, were found in the poison of L. lineatus but not in that of A. picta. Both species differ greatly on profiles of gland distribution: In L. lineatus, poison glands are organized in clusters whose position coincides with colored elements of the dorsum. These regions are evidenced through a set of displays, suggesting that poison location is announced to predators through skin colors. In contrast, A. picta presents lower densities of glands, distributed homogeneously. This simpler profile suggests a rather qualitative than quantitative investment in chemical defense, in agreement with the high toxicity attributed to dendrobatids in general. Our data suggest that both species are toxic or unpalatable and transmit common warning signals to predators, which represents a case of Müllerian mimicry. Copyright © 2011 Wiley Periodicals, Inc.

  20. Computerized axil tomographic scanning in tumors of the adrenal glands

    International Nuclear Information System (INIS)

    Albertotti, C.; Figueiredo, M.A.; Clemente Filho, A.S.; Secaf, F.

    1980-01-01

    Computed tomography was used for diagnosing primary or recurrent adrenal gland tumors, being positive in all nine cases and later confirmed at surgery. The tumors are adenocarcinoma (6 cases); pheochromocytoma (2); aldostenoma (1) an cyst(u). Comparison of selective arteriography, ultrasonography, scintigraphy and computed tomography has shown the later to be most accurate. (Author) [pt

  1. A Positive Emotional Bias in Confabulatory False Beliefs about Place

    Science.gov (United States)

    Turnbull, Oliver H.; Berry, Helen; Evans, Cathryn E.Y.

    2004-01-01

    Some neurological patients with medial frontal lesions exhibit striking confabulations. Most accounts of the cause of confabulations are cognitive, though the literature has produced anecdotal suggestions that confabulations may not be emotionally neutral, having a ("wish-fulfillment") bias that shapes the patient's perception of reality in a more…

  2. Towards "Zero" False Positive in Structural Health Monitoring

    National Research Council Canada - National Science Library

    Chiu, Wing K; Chang, F. K; Tian, Daniel T

    2007-01-01

    Structural Health Monitoring (SHM) is one aspect of a revolution based on the use of Smart Materials and Structures technologies that have the potential to provide major gains in structural performance and cost-efficient life management...

  3. Detection of Biological False Positive Syphilis Serum Reactions ...

    African Journals Online (AJOL)

    A comparative evaluation of reagin tests (Wassermann, VDRL, RPR) and fluorescent treponema antibody absorption tests (FTA-ABS) performed on blood specimens from 5 271 persons (2 493 pregnant women, 1 130 apparently healthy prospective employees, 1 345 newborn babies and 303 leprosy patients) showed that ...

  4. Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism

    International Nuclear Information System (INIS)

    Pons, F.; Vidal-Sicart, S.; Fuster, D.; Herranz, R.; Torregrosa, J.V.; Sabater, L.; Fernandez-Cruz, L.

    1997-01-01

    Technetium-99m sestamibi scintigraphy has become a valuable tool in locating parathyroid glands in patients with primary hyperparathyroidism. The aim of this study was to evaluate its usefulness in secondary hyperparathyroidism. Twenty patients were injected intravenously with 740 MBq of 99m Tc-sestamibi and images were obtained at 15 min and 2 h post injection. All patients underwent parathyroid ultrasonography (US) as well as bilateral surgical neck exploration and 64 parathyroid glands were removed. US revealed at least one enlarged gland in 15/20 patients (75%), while 99m Tc-sestamibi scintigraphy showed focal areas of increased uptake in at least one gland in 17/20 patients (85%). When imaging results for all glands were evaluated according to surgical results, sensitivity was 54% for parathyroid scintigraphy and 41% for US, and specificity was 89% for both imaging techniques. There was a discrepancy between the two imaging modalities in 28 glands (35%). The mean surgical weight of US-positive glands (1492±1436 mg) was significantly higher than that of US-negative glands (775±703 mg) (P 99m Tc-sestamibi scintigraphy are complementary imaging techniques in the preoperative localization of abnormal parathyroid glands in patients with secondary hyperparathyroidism. The limited sensitivity of the techniques means that patients will still require bilateral neck exploration; therefore routine preoperative parathyroid scanning in renal patients is not justified. (orig.)

  5. Unexpected Detection of Parotid Gland Malignancy during Primary Extracapsular Dissection

    OpenAIRE

    Mantsopoulos, Konstantinos; Velegrakis, Stylianos; Iro, Heinrich

    2015-01-01

    Objective To evaluate the oncologic and functional outcome in cases in which a false preoperative working hypothesis “benign parotid tumor” led to a primary extracapsular dissection being performed rather than a traditional, more radical surgical modality. Study Design Case series with chart review. Setting Academic tertiary referral center. Subjects and Methods The records of all patients treated for malignant tumors of the parotid gland between 2006 and 2012 were...

  6. Llama oviductal sperm reservoirs: involvement of bulbourethral glands.

    Science.gov (United States)

    Apichela, S A; Argañaraz, M E; Giuliano, S; Zampini, R; Carretero, I; Miragaya, M; Miceli, D C

    2014-04-01

    The aim of this study was to elucidate the role of llama seminal plasma in the formation of oviductal sperm reservoirs. Female llamas with follicles in the mature phase were mated with a bulbourethral glands-removed male. Females mated with nonbulbourethral glands-removed males were used as control. Oviducts were obtained by surgery 24 h after mating. The uterotubal junction and isthmus were examined by scanning electron microscopy, and mucopolysaccharides were identified by Alcian blue staining. To know the proteins probably involved in sperm reservoir formation, SDS-PAGE of seminal plasma (8% and 18% resolving gel) was made. Spermatozoa only adhered to the oviductal mucosa surface of uterotubal junction of females mated with nonbulbourethral glands-removed males confirming that seminal plasma and, in particular, bulbourethral secretions are related with the oviductal sperm reservoir formation. Histological sections showed sperm in the lumen, immersed in substance, positive for acid mucopolysaccharides. Alcian blue staining of seminal plasma proteins SDS-PAGE showed a band of high molecular weight containing mucopolysaccharides, only present in nonbulbourethral glands-removed males. Bulbourethral glands would secrete at least eight different proteins that most likely participate in the process of sperm storage in the oviduct. © 2013 Blackwell Verlag GmbH.

  7. Isolated lacrimal gland involvement in Rosai-Dorfman-Destombes disease

    Directory of Open Access Journals (Sweden)

    Gulwani Hanni

    2008-01-01

    Full Text Available Rosai-Dorfman-Destombes (sinus histiocytosis with massive lymphadenopathy disease is an uncommon disease characterized by benign proliferation of histiocytes, with painless lymph node enlargement and frequent extranodal disease. Orbital involvement occurs in 9-11% of cases. However, isolated Rosai-Dorfman-Destombes disease of the lacrimal gland without any systemic involvement is very rare with only three case reports. We describe here one such young male patient with unilateral lacrimal gland swelling. Excision biopsy revealed almost complete replacement of the lacrimal gland by lymphocytes, plasma cells and large pale histiocytes. The latter exhibited emperipolesis and stained positive for S-100 and CD68 on immunohistochemistry. Patient is well and has no other manifestation or recurrence of the disease during a follow-up of 24 months.

  8. True photographs and false memories.

    Science.gov (United States)

    Lindsay, D Stephen; Hagen, Lisa; Read, J Don; Wade, Kimberley A; Garry, Maryanne

    2004-03-01

    Some trauma-memory-oriented psychotherapists advise clients to review old family photo albums to cue suspected "repressed" memories of childhood sexual abuse. Old photos might cue long-forgotten memories, but when combined with other suggestive influences they might also contribute to false memories. We asked 45 undergraduates to work at remembering three school-related childhood events (two true events provided by parents and one pseudoevent). By random assignment, 23 subjects were also given their school classes' group photos from the years of the to-be-recalled events as memory cues. As predicted, the rate of false-memory reports was dramatically higher in the photo condition than in the no-photo condition. Indeed, the rate of false-memory reports in the photo condition was substantially higher than the rate in any previously published study.

  9. [Meibomian gland disfunction in computer vision syndrome].

    Science.gov (United States)

    Pimenidi, M K; Polunin, G S; Safonova, T N

    2010-01-01

    This article reviews ethiology and pathogenesis of dry eye syndrome due to meibomian gland disfunction (MDG). It is showed that blink rate influences meibomian gland functioning and computer vision syndrome development. Current diagnosis and treatment options of MDG are presented.

  10. Underpowered samples, false negatives, and unconscious learning.

    Science.gov (United States)

    Vadillo, Miguel A; Konstantinidis, Emmanouil; Shanks, David R

    2016-02-01

    The scientific community has witnessed growing concern about the high rate of false positives and unreliable results within the psychological literature, but the harmful impact of false negatives has been largely ignored. False negatives are particularly concerning in research areas where demonstrating the absence of an effect is crucial, such as studies of unconscious or implicit processing. Research on implicit processes seeks evidence of above-chance performance on some implicit behavioral measure at the same time as chance-level performance (that is, a null result) on an explicit measure of awareness. A systematic review of 73 studies of contextual cuing, a popular implicit learning paradigm, involving 181 statistical analyses of awareness tests, reveals how underpowered studies can lead to failure to reject a false null hypothesis. Among the studies that reported sufficient information, the meta-analytic effect size across awareness tests was d z = 0.31 (95 % CI 0.24-0.37), showing that participants' learning in these experiments was conscious. The unusually large number of positive results in this literature cannot be explained by selective publication. Instead, our analyses demonstrate that these tests are typically insensitive and underpowered to detect medium to small, but true, effects in awareness tests. These findings challenge a widespread and theoretically important claim about the extent of unconscious human cognition.

  11. Evaluation of the observation of breast glands condition in mammographic early detection programme

    International Nuclear Information System (INIS)

    Kleszczewska, J.; Zomer-Drozda, J.; Tarlowska, L.; Romejko, M.

    1993-01-01

    The results of mammography tests were evaluated for 542 female employees of higher schools during an observation continued over 1 to 7.5 years, and they were compared with the results of the first test. Among 22 cancers detected and confirmed by macroscopic examination, mammography result turned out to be false negative in 2 cases. A positive error occurred in 7 cases. Cancer developed during observation in 8 women, that is, in 4 women from the group of 365 who earlier had correct mammography results (1.1%) and another 4 in the group of 154 women originally showing benign changes in their breast glands (2.6%). This work confirms the importance of regular checkups in the mammographic early detection programme. (author)

  12. Evaluation of Ga-67 scintigraphy for salivary gland tumors

    International Nuclear Information System (INIS)

    Takase, Hiroshi; Toyama, Michio; Eguchi, Tooru; Maeda, Kadzuo

    1993-01-01

    It is often difficult to exactly grasp the malignancy of salivary gland tumor because of inadaptability of percutaneous biopsy. The purpose of this study is to discuss whether Ga-67 scintigraphy on patient with salivary gland tumor can provide useful information for differential diagnosis. We studied retrospectivelly the case records of twenty patients with parotid or submandibular gland tumors admitted to the Nippon Dental University, School of Dentistry at Niigata, between January 1984 and December 1991. The final diagnoses of these twenty patients were pleomorphic adenoma in 11, adenocarcinoma in 3, adenoid cystic carcinoma in 3, Warthin's tumor in 1, oncocytoma in 1, and carcinoma in pleomorphic adenoma in 1. The scintigraphic patterns of the twenty patients were classified as negative (-), weakly positive (+), moderate positive (++), strongly positive (+++). Malignant tumors showed increased activity in Ga-67 images except those in three patients with adenoid cystic carcinomas. We concluded that Ga-67 scintigraphy may be useful to distinguish benign salivary gland tumors from adenocarcinoma or carcinoma in pleomorphic adenoma, but not be useful in detection of adenoid cystic carcinoma. (author)

  13. Imaging of the major salivary glands

    DEFF Research Database (Denmark)

    Afzelius, Pia; Nielsen, Ming-Yuan; Ewertsen, Caroline

    2016-01-01

    The major salivary glands, submandibular, parotid and sublingual glands play an important role in preserving the oral cavity and dental health. Patients with problems of the major salivary glands may present with symptoms such as dry mouth, dysphagia and obstruction of duct, inflammation, severe...

  14. [Brunners gland hiperplasia. Report of two cases].

    Science.gov (United States)

    Padilla Ruiz, Maykel

    2014-04-01

    Brunner's gland hyperplasia is an infrequent benign injury located on the first or second portion of the duodenum. The disease spectrum includes diffuse nodular hyperplasia, circumscribed nodular hyperplasia, and Brunner's gland adenoma. We report two cases, one with an adenoma of Brunner's glands as a duodenal polyp and the other as a diffuse nodular hyperplasia of the duodenal bulb.

  15. Sleep loss produces false memories.

    Directory of Open Access Journals (Sweden)

    Susanne Diekelmann

    Full Text Available People sometimes claim with high confidence to remember events that in fact never happened, typically due to strong semantic associations with actually encoded events. Sleep is known to provide optimal neurobiological conditions for consolidation of memories for long-term storage, whereas sleep deprivation acutely impairs retrieval of stored memories. Here, focusing on the role of sleep-related memory processes, we tested whether false memories can be created (a as enduring memory representations due to a consolidation-associated reorganization of new memory representations during post-learning sleep and/or (b as an acute retrieval-related phenomenon induced by sleep deprivation at memory testing. According to the Deese, Roediger, McDermott (DRM false memory paradigm, subjects learned lists of semantically associated words (e.g., "night", "dark", "coal",..., lacking the strongest common associate or theme word (here: "black". Subjects either slept or stayed awake immediately after learning, and they were either sleep deprived or not at recognition testing 9, 33, or 44 hours after learning. Sleep deprivation at retrieval, but not sleep following learning, critically enhanced false memories of theme words. This effect was abolished by caffeine administration prior to retrieval, indicating that adenosinergic mechanisms can contribute to the generation of false memories associated with sleep loss.

  16. Evolutionary Psychology and False Confession

    Science.gov (United States)

    Bering, Jesse M.; Shackelford, Todd K.

    2005-01-01

    This paper presents comments on Kassin's review, (see record 2005-03019-002) of the psychology of false confessions. The authors note that Kassin's review makes a compelling argument for the need for legal reform in police interrogation practices. Because his work strikes at the heart of the American criminal justice system--its fairness--the…

  17. Working memory affects false memory production for emotional events.

    Science.gov (United States)

    Mirandola, Chiara; Toffalini, Enrico; Ciriello, Alfonso; Cornoldi, Cesare

    2017-01-01

    Whereas a link between working memory (WM) and memory distortions has been demonstrated, its influence on emotional false memories is unclear. In two experiments, a verbal WM task and a false memory paradigm for negative, positive or neutral events were employed. In Experiment 1, we investigated individual differences in verbal WM and found that the interaction between valence and WM predicted false recognition, with negative and positive material protecting high WM individuals against false remembering; the beneficial effect of negative material disappeared in low WM participants. In Experiment 2, we lowered the WM capacity of half of the participants with a double task request, which led to an overall increase in false memories; furthermore, consistent with Experiment 1, the increase in negative false memories was larger than that of neutral or positive ones. It is concluded that WM plays a critical role in determining false memory production, specifically influencing the processing of negative material.

  18. Blood sampling from adrenal gland vein

    International Nuclear Information System (INIS)

    Sun Yong; Ni Caifang

    2009-01-01

    Adrenal gland vein sampling is an interventional method to get the blood samples from the adrenal gland vein. The blood is obtained via a catheter which is selectively inserted in the adrenal gland vein. This technique is mainly used to be diagnostic for primary hyperaldosteronism. A full knowledge of the anatomy and variations of the adrenal gland vein, serious preoperative preparation and skilled catheterization manipulation are necessary for obtaining sufficient blood sample and for reducing the occurrence of complications. Providing the physicians with definite diagnostic evidence and being technically feasible, adrenal gland vein sampling should become one of the routine examinations for clarifying the cause of primary hyperaldosteronism. (authors)

  19. Trust, values and false consensus

    OpenAIRE

    Butler, Jeffrey V.; Giuliano, Paola; Guiso, Luigi

    2012-01-01

    Trust beliefs are heterogeneous across individuals and, at the same time, persistent across generations. We investigate one mechanism yielding these dual patterns: false consensus. In the context of a trust game experiment, we show that individuals extrapolate from their own type when forming trust beliefs about the same pool of potential partners – i.e., more (less) trustworthy individuals form more optimistic (pessimistic) trust beliefs - and that this tendency continues to color trust beli...

  20. With sadness comes accuracy; with happiness, false memory: mood and the false memory effect.

    Science.gov (United States)

    Storbeck, Justin; Clore, Gerald L

    2005-10-01

    The Deese-Roediger-McDermott paradigm lures people to produce false memories. Two experiments examined whether induced positive or negative moods would influence this false memory effect. The affect-as-information hypothesis predicts that, on the one hand, positive affective cues experienced as task-relevant feedback encourage relational processing during encoding, which should enhance false memory effects. On the other hand, negative affective cues are hypothesized to encourage item-specific processing at encoding, which should discourage such effects. The results of Experiment 1 are consistent with these predictions: Individuals in negative moods were significantly less likely to show false memory effects than those in positive moods or those whose mood was not manipulated. Experiment 2 introduced inclusion instructions to investigate whether moods had their effects at encoding or retrieval. The results replicated the false memory finding of Experiment 1 and provide evidence that moods influence the accessibility of lures at encoding, rather than influencing monitoring at retrieval of whether lures were actually presented.

  1. 11C-methionine PET, a novel method for measuring regional salivary gland function after radiotherapy of head and neck cancer

    International Nuclear Information System (INIS)

    Buus, Simon; Grau, Cai; Munk, Ole Lajord; Bender, Dirk; Jensen, Kenneth; Keiding, Susanne

    2004-01-01

    Background and purpose: Loss of salivary gland function is a distressing side-effect of radiotherapy (RT) for head and neck cancer. The aim of this study was to develop a positron emission tomography (PET) method for measuring regional salivary gland function in the major salivary glands irradiated during RT. Patients and methods: Eight head and neck cancer patients were included; two were examined before RT and six after parotid sparing RT. Patients were examined by dynamic 11 C-methionine PET of the major salivary glands and parotid gland salivary flow measurements. PET data were analysed using a kinetic model of salivary gland 11 C-methionine metabolism, in which salivary gland function was quantified by the net metabolic clearance of 11 C-methionine, K. Functional voxel-wise images of K were calculated and matched with the CT-dose-plan for comparing regional salivary gland function with the regional radiation dose. Results: Parotid gland K correlated positively with parotid gland salivary flow, indicating that K can be used as an index of salivary gland function. K of parotid and submandibular glands was reduced dependent on the median radiation dose. In one patient, receiving a heterogeneous radiation dose to the parotid glands, regional salivary gland function was inversely correlated to the regional radiation dose. Conclusions: Salivary gland function can be measured by dynamic 11 C-methionine PET. The net metabolic clearance of 11 C-methionine of salivary glands was reduced dependent on the radiation dose. Dynamic 11 C-methionine PET offers a method for studying the individual response of the major salivary glands to irradiation

  2. Psychoactive drugs and false memory: comparison of dextroamphetamine and delta-9-tetrahydrocannabinol on false recognition

    Science.gov (United States)

    Ballard, Michael E.; Gallo, David A.; de Wit, Harriet

    2014-01-01

    Rationale Several psychoactive drugs are known to influence episodic memory. However, these drugs’ effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Objectives Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ9-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger–McDermott (DRM) illusion. Methods Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. Results As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs’ effects on true memory were positively correlated with their effects on false memory. Conclusions Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories. PMID:21647577

  3. Psychoactive drugs and false memory: comparison of dextroamphetamine and δ-9-tetrahydrocannabinol on false recognition.

    Science.gov (United States)

    Ballard, Michael E; Gallo, David A; de Wit, Harriet

    2012-01-01

    Several psychoactive drugs are known to influence episodic memory. However, these drugs' effects on false memory, or the tendency to incorrectly remember nonstudied information, remain poorly understood. Here, we examined the effects of two commonly used psychoactive drugs, one with memory-enhancing properties (dextroamphetamine; AMP), and another with memory-impairing properties (Δ(9)-tetrahydrocannabinol; THC), on false memory using the Deese/Roediger-McDermott (DRM) illusion. Two parallel studies were conducted in which healthy volunteers received either AMP (0, 10, and 20 mg) or THC (0, 7.5, and 15 mg) in within-subjects, randomized, double-blind designs. Participants studied DRM word lists under the influence of the drugs, and their recognition memory for the studied words was tested 2 days later, under sober conditions. As expected, AMP increased memory of studied words relative to placebo, and THC reduced memory of studied words. Although neither drug significantly affected false memory relative to placebo, AMP increased false memory relative to THC. Across participants, both drugs' effects on true memory were positively correlated with their effects on false memory. Our results indicate that AMP and THC have opposing effects on true memory, and these effects appear to correspond to similar, albeit more subtle, effects on false memory. These findings are consistent with previous research using the DRM illusion and provide further evidence that psychoactive drugs can affect the encoding processes that ultimately result in the creation of false memories.

  4. Diagnosing parathyroid glands: a revision

    International Nuclear Information System (INIS)

    Soroa, V.E.; Rank, G.

    2015-01-01

    Descriptions of the different benign parathyroid pathologies: primary, secondary and tertiary hyperparathyroidism and the possible diagnostic nuclear medicine techniques. We discuss the different acquisition modalities: planar, pinhole, subtraction, SPECT, SPECT/CT and PET/CT. Optimal recommendations for the patient preparation and acquisition, as well as false positive and negative results are also mentioned. Radiopharmaceuticals dosimetry is included. Statements related to other imaging modalities and the one with highest specificity: Ultrasound plus Nuclear Medicine. Emphasize of optimal results of the dual Phase 99m Tc-Setamibi in SPECT and the best selection with SPECT/CT, if available. Mention is done of the curative surgical treatment and the selective venous PTH sampling (excellent result if pre-surgical levels descended to 50 %, circumstances of false outcomes are also presented). Brief enumeration of PET/CT compounds, as another possibility that still has to proof its role in the diagnostic armamentarium of parathyroid pathology. Conclusion: The best diagnostic performance has been obtained with 99m Tc-Sestamibi in SPECT/CT as well as with the subtraction 131 I / 99m Tc-Sestamibi or 99m Tc-pertecneciate/ 99m Tc-Sestamibi methods. Nuclear Medicine is relevant in pointing parathyroid pathology in the surgical act and for a second look re-intervention. PET/CT radiopharmaceuticals are other possibilities that must still demonstrate its value in the diagnostic armamentarium of parathyroid pathologies. (authors) [es

  5. False-Positive Results in a Recombinant Severe Acute Respiratory Syndrome-Associated Coronavirus (SARS-CoV) Nucleocapsid Enzyme-Linked Immunosorbent Assay Due to HCoV-OC43 and HCoV-229E Rectified by Western Blotting with Recombinant SARS-CoV Spike Polypeptide

    OpenAIRE

    Woo, Patrick C. Y.; Lau, Susanna K. P.; Wong, Beatrice H. L.; Chan, Kwok-Hung; Hui, Wai-Ting; Kwan, Grace S. W.; Peiris, J. S. Malik; Couch, Robert B.; Yuen, Kwok-Yung

    2004-01-01

    Using paired serum samples obtained from patients with illness associated with increases in anti-human coronavirus OC43 (HCoV-OC43) or anti-HCoV-229E antibodies, we examined the possibility of false-positive results detected in a recombinant severe acute respiratory syndrome (SARS)-associated coronavirus (SARS-CoV) nucleocapsid protein immunoglobulin G enzyme-linked immunosorbent assay (ELISA). Three of the 21 and 1 of the 7 convalescent-phase serum samples from persons with increases in anti...

  6. The False Premises and False Promises of the Movement to Privatize Public Education.

    Science.gov (United States)

    Hawley, Willis D.

    1995-01-01

    Argues that the movement to provide parents with financial incentives to send students to private schools will increase the racial, ethnic, and socioeconomic homogeneity of American schools. Six common assumptions about the positive effects of privatizing education are examined and deemed false. Probable costs of tuition vouchers for private…

  7. Submandibular gland function and parotid gland function in Bell's palsy, 3

    International Nuclear Information System (INIS)

    Ino, Chiyonori; Yamashita, Toshio; Kato, Mako; Kumazawa, Tadami

    1986-01-01

    With the use of sup(99m)Tc, we attempted to measure simultaneously submandibular gland function and parotid gland function, which is thought not to be controlled by the facial nerve, in patients with unilateral Bell's palsy. For comparison, the lachrymal gland function of some patients was measured by the thread method. We found that facial palsy sometimes affects parotid gland function as well as submandibular gland function. In 60 % of the patients the function of the two glands tended to be affected in the same way. Lachrymal gland function tended to be affected in a similar way to parotid gland function. We conclude that the chorda tympani and the greater petrosal nerve may influence parotid gland function. (author)

  8. Nuclear war as false memory

    Directory of Open Access Journals (Sweden)

    John Timberlake

    2014-10-01

    Full Text Available In this paper Timberlake outlines aspects of his creative practice as an artist, explaining his fascination for the ‘fictions of nuclear war’ – a war that never happened and so became the subject of ‘false memory’. Highlighting discontinued historical trajectories, the author shows how the cultural legacy of Britain’s nuclear test programme of the 1950s and ’60s may be explored meaningfully in paintings and photography resulting from his archival research at the Imperial War Museum in London.

  9. False advertising in the greenhouse?

    Science.gov (United States)

    Banse, K.

    1991-12-01

    Most scientists are convinced of the importance of their own research subjects. Broecker [1991] has deplored the temptation, if not the tendency, to go overboard and exaggerate this importance once funding enters the mind. In particular, he alleges inflated or even false claims by biological (and other) oceanographers regarding the relevance of their research to the "greenhouse effect," caused by the anthropogenic enhancement of the atmospheric CO2 content. He writes [Broecker, 1991, p. 191]: "In my estimation, on any list of subjects requiring intense study with regard to the prediction of the consequences of CO2 buildup in the atmosphere, I would place marine biological cycles near the bottom."

  10. Pituitary gland development: an update.

    Science.gov (United States)

    Bancalari, Rodrigo E; Gregory, Louise C; McCabe, Mark J; Dattani, Mehul T

    2012-01-01

    The embryonic development of the pituitary gland involves a complex and highly spatio-temporally regulated network of integrating signalling molecules and transcription factors. Genetic mutations in any of these factors can lead to congenital hypopituitarism in association with a wide spectrum of craniofacial/midline defects ranging from incompatibility with life to holoprosencephaly (HPE) and cleft palate and septo-optic dysplasia (SOD). Increasing evidence supports a genotypic overlap with hypogonadotrophic hypogonadal disorders such as Kallmann syndrome, which is consistent with the known overlap in phenotypes between these disorders. This chapter reviews the cascade of events leading up to the successful development of the pituitary gland and to highlight key areas where genetic variations can occur thus leading to congenital hypopituitarism and associated defects. Copyright © 2012 S. Karger AG, Basel.

  11. Revisiting the False Confession Problem.

    Science.gov (United States)

    Alvarez-Toro, Viviana; Lopez-Morales, Cesar A

    2018-03-01

    Despite the existence of important safeguards in our criminal legal system, innocent suspects often succumb to forceful and deceptive interrogation techniques. Among those over-represented members of the false confessor population are minors, people with cognitive and intellectual disabilities, and those with psychiatric disorders. Some of the confessions made by these at-risk populations can hardly be considered voluntary or reliable, but they are generally admitted at trial, regardless of their prejudicial effect. Forensic psychiatrists should become more involved in the overall process of evaluating confessions, not only testifying in courts, but also assisting policymakers in reforming the interrogation process and influencing the legal process. Thus, forensic psychiatrists may give their expert opinion by providing proper training to police interrogators and examining videotaped interrogations. In addition, forensic experts can be instrumental in contributing to three legal solutions that we propose to the false confession problem: a constitutional approach, an evidence law approach, and a jury instruction approach. Each of these approaches requires forensic psychiatrists to help judges and jurors understand the coercive nature of the interrogation process and its effect on suspects' behavior. © 2018 American Academy of Psychiatry and the Law.

  12. Prognosis and submandibular gland function

    International Nuclear Information System (INIS)

    Ino, Chiyonori; Yamashita, Toshio; Hanaoka, Mako; Kumazawa, Tadami

    1984-01-01

    Submandibular gland function was tested with sup(99m)Tc-pertechnetate scan 10 days and 3-4 weeks after the onset Bell's palsy, and the results and prognoses were correlated. In the first report we divided the cases into groups A, B and C, and this time group D classified in S.S.R. was poor. Groups A and D can be differentiated by submandibular gland scan within 10 days after the onset; that is to say, the prognosis of more than half the cases can be determined in this early phase. Especially, it is noticeable that group D showing the poor prognosis is differentiated within 10 days after the onset. This method was compared with other tests of facial palsy. Four to five weeks after the onset all tests were of equal accuracy in predicting the prognosis of each group. Within 10 days after the onset, however, submandibular gland scan seems to be more useful than the other tests. (author)

  13. Postoperative radiotherapy for parotid gland malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Keun Yong; Wu, Hong Gyun; Kim, Jae Sung; Park, Charn Il; Kim, Kwang Hyun; Lee, Chae Seo [Seoul National University College of Medicine, Seoul (Korea, Republic of); Kim, In Ah [Bundang Seoul National University Hospital, Seongnam (Korea, Republic of)

    2005-09-15

    The aim of this study was to evaluate the clinical results of postoperative radiotherapy for parotid gland malignancy, and determine prognostic factors for locoregional control and survival. Between 1980 and 2002, 130 patients with parotid malignancy were registered in the database of the Department of Radiation Oncology, Seoul National University Hospital. The subjects of this analysis were the 72 of these 130 patients who underwent postoperative irradiation. There were 42 males and 30 females, with a median age of 46.5 years. The most common histological type was a mucoepidermoid carcinoma. There were 6, 23, 23 and 20 patients in Stages I, II, III and IV, respectively. The median dose to the tumor bed was 60 Gy, with a median fraction size of 1.8 Gy. The overall 5 and 10 year survival rates were 85 and 76%, respectively. The five-year locoregional control rate was 85%, which reached a plateau phase after 6 years. Sex and histological type were found to be statistically significant for overall survival from a multivariate analysis. No other factors, including age, facial nerve palsy and stage, were related to overall survival. For locoregional control, nodal involvement and positive resection margin were associated with poor local control. Histological type, tumor size, perineural invasion and type of surgery were not significant for locoregional control. A high survival rate of parotid gland malignancies, with surgery and postoperative radiotherapy, was confirmed. Sex and histological type were significant prognostic factors for overall survival. Nodal involvement and a positive resection margin were associated with poor locoregional control.

  14. Introducing False EUR and False EUR exchange rates

    Science.gov (United States)

    Ausloos, M.; Ivanova, K.

    2000-10-01

    The Euro ( EUR) is a new currency introduced by the European Community. Its exchange rate is very puzzling. We have invented a false Euro ( FEUR) dating back to 1993 and have derived the exchange rates of the FEUR with respect to currencies not belonging to the EUR, i.e., DKK, CHF, JPY and USD. This allows us to search for correlations between the fluctuations preexisting to the introduction of EUR and present ones in such financial data. The detrended fluctuation analysis ( DFA) statistical method is used. This leads to assume a power-law behavior, i.e., a scaling hypothesis, through an exponent α. The latter has demonstrated its usefulness for the investigations of long-range power-law correlations in several types of financial sequences. Our findings show that the α exponent interestingly characterizes fractional Brownian motion of the currency exchange rates between EUR and DKK over a 25 day interval, and usual Brownian motion otherwise and for the three other investigated exchange rates. We can devise an investment strategy based on the localα technique and obtain appreciable gains for the time being.

  15. Bug hunting with false negatives

    NARCIS (Netherlands)

    Calamé, J.R.; Ioustinova, N.; Pol, van de J.C.; Sidorova, N.; Davies, J.; Gibbons, J.

    2007-01-01

    Safe data abstractions are widely used for verification purposes. Positive verification results can be transferred from the abstract to the concrete system. When a property is violated in the abstract system, one still has to check whether a concrete violation scenario exists. However, even when the

  16. Submandibular salivary gland transfer prevents radiation-induced xerostomia

    International Nuclear Information System (INIS)

    Jha, Naresh; Seikaly, Hadi; McGaw, Timothy; Coulter, Linda

    2000-01-01

    Background: Xerostomia is a significant morbidity of radiation therapy in the management of head and neck cancers. We hypothesized that the surgical transfer of one submandibular salivary gland to submental space, outside the proposed radiation field, prior to starting radiation treatment, would prevent xerostomia. Methods: We are conducting a prospective clinical trial where the submandibular gland is transferred as part of the surgical intervention. The patients are followed clinically, with salivary flow studies and University of Washington quality of life questionnaire. Results: We report early results of 16 patients who have undergone this procedure. Seven patients have finished and 2 patients are currently undergoing radiation treatment. In 2 patients, no postoperative radiation treatment was indicated. Two patients are waiting to start radiation treatment and 2 patients refused treatment after surgery. The surgical transfer was abandoned in 1 patient. All of the transferred salivary glands were positioned outside the proposed radiation fields and were functional. The patients did not complain of any xerostomia and developed only minimal oral mucositis. There were no surgical complications. Conclusions: Surgical transfer of a submandibular salivary gland to the submental space (outside the radiation field) preserves its function and prevents the development of radiation-induced xerostomia

  17. Multifocal Adenomatous Oncocytic Hyperplasia of the Parotid Gland

    Science.gov (United States)

    Kinoshita, Yuichi; Harada, Hiroshi; Kobayashi, Tadao K.; Yoshizawa, Katsuhiko; Yuri, Takashi; Takasu, Kosho; Tsubura, Airo; Shikata, Nobuaki

    2014-01-01

    Multifocal adenomatous oncocytic hyperplasia (MAOH) is a non-neoplastic lesion that is classified as oncocytosis. MAOH is a rare entity of the parotid gland and accounts for approximately 0.1% of salivary gland lesions. Here, we report a case of MAOH of the parotid gland. The patient was a 71-year-old woman who presented with discomfort at the left side of her neck. Fine-needle aspiration cytology of the parotid gland revealed a loose sheet-like cluster of round to polygonal cells with granular cytoplasm against a hemorrhagic background. The cells had round to oval, centrally located nuclei with granular chromatin and without distinct nucleoli. Histologically, the lesion was formed of many variable-sized nodules, comprising oncocyte-like cells with small round nuclei and eosinophilic granular cytoplasm that was positive for mitochondrial antibodies. The diagnosis of MAOH is difficult to make by cytology alone, because the findings overlap with those of other oncocytic lesions. In particular, the cytological findings of MAOH have not been sufficiently reported to date. A correlation of cytology and histology was expected. PMID:25580104

  18. Multifocal Adenomatous Oncocytic Hyperplasia of the Parotid Gland

    Directory of Open Access Journals (Sweden)

    Yuichi Kinoshita

    2014-12-01

    Full Text Available Multifocal adenomatous oncocytic hyperplasia (MAOH is a non-neoplastic lesion that is classified as oncocytosis. MAOH is a rare entity of the parotid gland and accounts for approximately 0.1% of salivary gland lesions. Here, we report a case of MAOH of the parotid gland. The patient was a 71-year-old woman who presented with discomfort at the left side of her neck. Fine-needle aspiration cytology of the parotid gland revealed a loose sheet-like cluster of round to polygonal cells with granular cytoplasm against a hemorrhagic background. The cells had round to oval, centrally located nuclei with granular chromatin and without distinct nucleoli. Histologically, the lesion was formed of many variable-sized nodules, comprising oncocyte-like cells with small round nuclei and eosinophilic granular cytoplasm that was positive for mitochondrial antibodies. The diagnosis of MAOH is difficult to make by cytology alone, because the findings overlap with those of other oncocytic lesions. In particular, the cytological findings of MAOH have not been sufficiently reported to date. A correlation of cytology and histology was expected.

  19. Fijación de radioyodo en huesos maxilares simulando metástasis en pacientes con Carcinoma Diferenciado de Tiroides (CDT): False- Positive images in patients with Differentiated Thyroid Carcinoma. (DTC) Uptake of 131-I in maxillary bones mimicking salivary glands

    OpenAIRE

    O. J. Degrossi; S. Gutiérrez; A. Fadel; E. B. Degrossi; M. C. Valdivieso; R. L. Balbuena; M. del C. Alak; M. de Cabrejas

    2008-01-01

    En estudios centellográficos con 131I (CCT) para seguimiento, postablación o tratamiento de pacientes portadores de carcinoma diferenciado de tiroides (CDT) se observan frecuentemente en tiempos precoces áreas de captación del radiotrazador en macizo facial. Estas áreas corresponden, generalmente, a glándulas salivares y extremo anterior de mucosa nasal y se mantienen durante las primeras 48 horas y no son observadas generalmente a las 72 horas. Pero con menor frecuencia se presentan otras qu...

  20. Radiological diagnosis of the adrenal glands

    International Nuclear Information System (INIS)

    Engelbrecht, V.

    2005-01-01

    The adrenal gland is a common site of disease involving hormonal dysfunction as well as benign and malignant masses. Radiology, especially computed tomography (CT) and magnetic resonance (MR), plays a critical role in detecting and characterizing diseases affecting the adrenal gland. This paper contains a summary of the most important diseases of the adrenal gland and presents criteria for differentiating between benign and malignant masses as well as an algorithm for the diagnostic steps in incidentaloma. (orig.)

  1. Expression of Anti-apoptotic Protein BAG3 in Human Sebaceous Gland Carcinoma of the Eyelid.

    Science.gov (United States)

    Yunoki, Tatsuya; Tabuchi, Yoshiaki; Hayashi, Atsushi

    2017-04-01

    Bcl-2-associated athanogene 3 (BAG3), a co-chaperone of heat shock protein 70 (HSP70), has been shown to play a role in anti-apoptosis of various malignant tumors. In this study, the expression of BAG3 was examined in human sebaceous gland carcinoma of the eyelid. The expression of BAG3 was evaluated by immunohistochemistry of surgical samples from 5 patients with sebaceous gland carcinoma in the eyelid. BAG3 was positive diffusely in the cytoplasm in all patients. The average positive rate of BAG3 was 73.0±26.0% in tumor cells of all patients. BAG3 was highly expressed in sebaceous gland carcinoma of the eyelid. BAG3 may play an important role in the pathogenesis and progression of sebaceous gland carcinoma of the eyelid. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  2. Parotitis and Sialendoscopy of the Parotid Gland.

    Science.gov (United States)

    Hernandez, Stephen; Busso, Carlos; Walvekar, Rohan R

    2016-04-01

    Nonneoplastic disorders of the salivary glands involve inflammatory processes. These disorders have been managed conservatively with antibiotics, warm compresses, massage, sialogogues, and adequate hydration. Up to 40% of patients may have an inadequate response or persistent symptoms. When conservative techniques fail, the next step is operative intervention. Sialendoscopy offers a minimally invasive option for the diagnosis and management of chronic inflammatory disorders of the salivary glands and offers the option of gland and function preservation. In this article, we review some of the more common nonneoplastic disorders of the parotid gland, indications for diagnostic and interventional sialendoscopy, and operative techniques. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Lacrimal Gland Pathologies from an Anatomical Perspective

    Directory of Open Access Journals (Sweden)

    Mahmut Sinan Abit

    2015-06-01

    Full Text Available Most of the patients in our daily practice have one or more ocular surface disorders including conjucntivitis, keratitis, dry eye disease, meibomian gland dysfunction, contact lens related symptoms, refractive errors,computer vision syndrome. Lacrimal gland has an important role in all above mentioned pathologies due to its major secretory product. An anatomical and physiological knowledge about lacrimal gland is a must in understanding basic and common ophthalmological cases. İn this paper it is aimed to explain the lacrimal gland diseases from an anatomical perspective.

  4. Exocrine glands of Schwarziana quadripunctata (Hymenoptera, Apinae, Meliponini

    Directory of Open Access Journals (Sweden)

    C. CRUZ-LANDIM

    Full Text Available This article describes the location, anatomy, histology and ontogeny of adult Schwarziana quadripunctata exocrine glands. These glands appear either as individualized organs (salivary gland system and Dufour gland or as epidermis differentiation (tegumentary glands. Variations in the occurrence and degree of development among colony components with regard to their degree of maturity are also described.

  5. Morphological Features of the Porcine Lacrimal Gland and Its Compatibility for Human Lacrimal Gland Xenografting

    OpenAIRE

    Henker, Robert; Scholz, Michael; Gaffling, Simone; Asano, Nagayoshi; Hampel, Ulrike; Garreis, Fabian; Hornegger, Joachim; Paulsen, Friedrich

    2013-01-01

    In this study, we present first data concerning the anatomical structure, blood supply and location of the lacrimal gland of the pig. Our data indicate that the porcine lacrimal gland may serve as a potential xenograft candidate in humans or as an animal model for engineering of a bioartificial lacrimal gland tissue construct for clinical application. For this purpose, we used different macroscopic preparation techniques and digital reconstruction of the histological gland morphology to gain ...

  6. Complementarity in false memory illusions.

    Science.gov (United States)

    Brainerd, C J; Reyna, V F

    2018-03-01

    For some years, the DRM illusion has been the most widely studied form of false memory. The consensus theoretical interpretation is that the illusion is a reality reversal, in which certain new words (critical distractors) are remembered as though they are old list words rather than as what they are-new words that are similar to old ones. This reality-reversal interpretation is supported by compelling lines of evidence, but prior experiments are limited by the fact that their memory tests only asked whether test items were old. We removed that limitation by also asking whether test items were new-similar. This more comprehensive methodology revealed that list words and critical distractors are remembered quite differently. Memory for list words is compensatory: They are remembered as old at high rates and remembered as new-similar at very low rates. In contrast, memory for critical distractors is complementary: They are remembered as both old and new-similar at high rates, which means that the DRM procedure induces a complementarity illusion rather than a reality reversal. The conjoint recognition model explains complementarity as a function of three retrieval processes (semantic familiarity, target recollection, and context recollection), and it predicts that complementarity can be driven up or down by varying the mix of those processes. Our experiments generated data on that prediction and introduced a convenient statistic, the complementarity ratio, which measures (a) the level of complementarity in memory performance and (b) whether its direction is reality-consistent or reality-reversed. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  7. Leg tendon glands in male bumblebees ( Bombus terrestris): structure, secretion chemistry, and possible functions

    Science.gov (United States)

    Jarau, Stefan; Žáček, Petr; Šobotník, Jan; Vrkoslav, Vladimír; Hadravová, Romana; Coppée, Audrey; Vašíčková, Soňa; Jiroš, Pavel; Valterová, Irena

    2012-12-01

    Among the large number of exocrine glands described in bees, the tarsal glands were thought to be the source of footprint scent marks. However, recent studies showed that the compounds used for marking by stingless bees are secreted by leg tendon instead of tarsal glands. Here, we report on the structure of leg tendon glands in males of Bombus terrestris, together with a description of the chemical composition of their secretions and respective changes of both during the males' lives. The ultrastructure of leg tendon glands shows that the secretory cells are located in three independent regions, separated from each other by unmodified epidermal cells: in the femur, tibia, and basitarsus. Due to the common site of secretion release, the organ is considered a single secretory gland. The secretion of the leg tendon glands of B. terrestris males differs in its composition from those of workers and queens, in particular by (1) having larger proportions of compounds with longer chain lengths, which we identified as wax esters; and (2) by the lack of certain hydrocarbons (especially long chain dienes). Other differences consist in the distribution of double bond positions in the unsaturated hydrocarbons that are predominantly located at position 9 in males but distributed at seven to nine different positions in the female castes. Double bond positions may change chemical and physical properties of a molecule, which can be recognized by the insects and, thus, may serve to convey specific information. The function of male-specific compounds identified from their tendon glands remains elusive, but several possibilities are discussed.

  8. Too Good to be False : Nonsignificant Results Revisited

    NARCIS (Netherlands)

    Hartgerink, Chris H J; Wicherts, Jelte M.; Van Assen, M. A. L. M.

    2017-01-01

    Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST) is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant

  9. Is salivary gland function altered in noninsulin-dependent diabetes mellitus and obesity-insulin resistance?

    Science.gov (United States)

    Ittichaicharoen, Jitjiroj; Chattipakorn, Nipon; Chattipakorn, Siriporn C

    2016-04-01

    Salivary gland dysfunction in several systemic diseases has been shown to decrease the quality of life in patients. In non-insulin dependent diabetes mellitus (NIDDM), inadequate salivary gland function has been evidenced to closely associate with this abnormal glycemic control condition. Although several studies demonstrated that NIDDM has a positive correlation with impaired salivary gland function, including decreased salivary flow rate, some studies demonstrated contradictory findings. Moreover, the changes of the salivary gland function in pre-diabetic stage known as insulin resistance are still unclear. The aim of this review is to comprehensively summarize the current evidence from in vitro, in vivo and clinical studies regarding the relationship between NIDDM and salivary gland function, as well as the correlation between obesity and salivary gland function. Consistent findings as well as controversial reports and the mechanistic insights regarding the effect of NIDDM and obesity-insulin resistance on salivary gland function are also presented and discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Pituitary gland imaging and outcome.

    Science.gov (United States)

    Di Iorgi, Natascia; Morana, Giovanni; Gallizia, Anna Lisa; Maghnie, Mohamad

    2012-01-01

    Magnetic resonance imaging (MRI) allows a detailed and precise anatomical study of the pituitary gland by differentiating between the anterior and posterior pituitary lobes. The identification of posterior pituitary hyperintensity, now considered a marker of neurohypophyseal functional integrity, has been the most striking advance for the diagnosis and understanding of anterior and posterior pituitary diseases. The advent of MRI has in fact led to a significant improvement in the understanding of the pathogenesis of disorders that affect the hypothalamo-pituitary area. Today, there is convincing evidence to support the hypothesis that marked MRI differences in pituitary morphology indicate a diverse range of disorders which affect the organogenesis and function of the anterior pituitary gland with different prognoses. Furthermore, the association of extrapituitary malformations accurately defined by MRI has supported a better definition of several conditions linked to pituitary hormone deficiencies and midline defects. MRI is a very informative procedure that should be used to support a diagnosis of hypopituitarism. It is useful in clinical management, because it helps endocrinologists determine which patients to target for further molecular studies and genetic counselling, which ones to screen for additional hormone deficits, and which ones may need growth hormone replacement into adult life. Copyright © 2012 S. Karger AG, Basel.

  11. Comparative ultrasound measurement of normal thyroid gland ...

    African Journals Online (AJOL)

    2011-08-31

    Aug 31, 2011 ... the normal thyroid gland has a homogenous increased medium level echo texture. The childhood thyroid gland dimension correlates linearly with age and body surface unlike adults. [14] Iodothyronine (T3) and thyroxine (T4) are thyroid hormones which function to control the basal metabolic rate (BMR).

  12. Ductal carcinoma of the parotid gland.

    Science.gov (United States)

    Eriksen, H E; Greisen, O; Hastrup, N

    1987-06-01

    A case of ductal carcinoma of the parotid gland is described. The medical literature contains only 13 previous reports on this kind of adenocarcinoma of the parotid gland. The tumour is characterized by its histologic resemblance to ductal carcinomas of the breast and prostate. The course of previously described cases suggests that this tumour has a highly aggressive biological behaviour.

  13. Effects of depressive disorder on false memory for emotional information.

    Science.gov (United States)

    Yeh, Zai-Ting; Hua, Mau-Sun

    2009-01-01

    This study explored with a false memory paradigm whether (1) depressed patients revealed more false memories and (2) whether more negative false than positive false recognition existed in subjects with depressive disorders. Thirty-two patients suffering from a major depressive episode (DSM-IV criteria), and 30 age- and education-matched normal control subjects participated in this study. After the presentation of a list of positive, negative, and neutral association items in the learning phase, subjects were asked to give a yes/no response in the recognition phase. They were also asked to rate 81 recognition items with emotional valence scores. The results revealed more negative false memories in the clinical depression group than in the normal control group; however, we did not find more negative false memories than positive ones in patients. When compared with the normal group, a more conservative response criterion for positive items was evident in patient groups. It was also found that when compared with the normal group, the subjects in the depression group perceived the positive items as less positive. On the basis of present results, it is suggested that depressed subjects judged the emotional information with criteria different from normal individuals, and patients' emotional memory intensity is attenuated by their mood.

  14. Associations between xerostomia, histopathological alterations, and autonomic innervation of labial salivary glands in men in late midlife.

    Science.gov (United States)

    Sørensen, Christiane Elisabeth; Larsen, Jytte Overgaard; Reibel, Jesper; Lauritzen, Martin; Mortensen, Erik Lykke; Osler, Merete; Pedersen, Anne Marie Lynge

    2014-09-01

    One aim of the present study was to investigate whether symptoms of oral dryness (xerostomia) during daytime, assessed in a study group of middle-aged male positive and negative outliers in cognition scores, were associated with age-related degenerative changes in human labial salivary glands and with quantitative measures of the glandular autonomic innervation. Another aim was to study the relation between the autonomic innervation and loss of secretory acinar cells in these glands. Labial salivary gland biopsies were taken from the lower lip from 190 men, born in 1953 and members of the Danish Metropolit birth cohort, who were examined for age-related changes in cognitive function and dental health as part of the Copenhagen University Center for Healthy Aging clinical neuroscience project. The glands were routinely processed and semi-quantitatively analyzed for inflammation, acinar atrophy, fibrosis, and adipocyte infiltration. Sections of labial salivary gland tissue were stained with the panneuronal marker PGP 9.5. In a subsample of 51 participants, the autonomic innervation of the glands was analyzed quantitatively by use of stereology. Labial salivary gland tissue samples from 33% of all participants displayed moderate to severe acinar atrophy and fibrosis (31%). Xerostomia was not significantly associated with structural changes of labial salivary glands, but in the subsample it was inversely related to the total nerve length in the glandular connective tissue. Acinar atrophy and fibrosis were negatively correlated with the parenchymal innervation and positively related to diffuse inflammation. The results from the present study indicate that aspects of the autonomic innervation of labial salivary glands may play a role in the occurrence of xerostomia which in the present study group was not significantly associated with degenerative changes in these glands. The findings further indicate that the integrity of labial salivary gland acini is related to the

  15. Gordon Research Conference on Mammary Gland Biology

    International Nuclear Information System (INIS)

    1989-01-01

    The 1989 conference was the tenth in the series of biennial Gordon Research Conferences on Mammary Gland Biology. Traditionally this conference brings together scientists from diverse backgrounds and experience but with a common interest in the biology of the mammary gland. Investigators from agricultural and medical schools, biochemists, cell and molecular biologists, endocrinologists, immunologists, and representatives from the emerging biotechnology industries met to discuss current concepts and results on the function and regulation of the normal and neoplastic mammary gland in a variety of species. Of the participants, approximately three-fourths were engaged in studying the normal mammary gland function, whereas the other quarter were engaged in studying the neoplastic gland. The interactions between scientists, clinicians, veterinarians examining both normal and neoplastic cell function serves to foster the multi-disciplinary goals of the conference and has stimulated many cooperative projects among participants in previous years

  16. Homeobox Genes in the Rodent Pineal Gland

    DEFF Research Database (Denmark)

    Rath, Martin Fredensborg; Rohde, Kristian; Klein, David C

    2013-01-01

    The pineal gland is a neuroendocrine gland responsible for nocturnal synthesis of melatonin. During early development of the rodent pineal gland from the roof of the diencephalon, homeobox genes of the orthodenticle homeobox (Otx)- and paired box (Pax)-families are expressed and are essential...... for normal pineal development consistent with the well-established role that homeobox genes play in developmental processes. However, the pineal gland appears to be unusual because strong homeobox gene expression persists in the pineal gland of the adult brain. Accordingly, in addition to developmental...... functions, homeobox genes appear to be key regulators in postnatal phenotype maintenance in this tissue. In this paper, we review ontogenetic and phylogenetic aspects of pineal development and recent progress in understanding the involvement of homebox genes in rodent pineal development and adult function...

  17. Cancer of the thyroid and salivary glands

    International Nuclear Information System (INIS)

    Ezaki, H.; Hayashi, Y.; Ishimaru, Toranosuke; Takeichi, N.

    1986-01-01

    The relationship of atomic bomb exposure to tumors of the head and neck has been studied in detail for the thyroid and salivary gland. It has been deomonstrated by animal experiments and studies conducted on those undergoing radiation therapy of the neck during childhood, and on those exposed to radioactive fallout from hydrogen-bomb tests in the Marshall Islands, that thyroid neoplasms can be induced by radiation. Although it was assumed that radiation would ahve a similar effect on the salivary gland located near the thyroid gland, it was in the 1970s that studies were commenced on the salivary gland. A study of the Adult Health Study population presented data which show that the incidence of salivary gland tumors was 9.3-fold higher in the group exposed to 300+ rad than in the control group and when confined only to malignant tumors the incidence was 21.8-fold higher

  18. Mood-congruent true and false memory: effects of depression.

    Science.gov (United States)

    Howe, Mark L; Malone, Catherine

    2011-02-01

    The Deese/Roediger-McDermott paradigm was used to investigate the effect of depression on true and false recognition. In this experiment true and false recognition was examined across positive, neutral, negative, and depression-relevant lists for individuals with and without a diagnosis of major depressive disorder. Results showed that participants with major depressive disorder falsely recognised significantly more depression-relevant words than non-depressed controls. These findings also parallel recent research using recall instead of recognition and show that there are clear mood congruence effects for depression on false memory performance. © 2011 Psychology Press, an imprint of the Taylor & Francis Group, an Informa business

  19. Metastatic Breast Carcinoma to the Prostate Gland

    Directory of Open Access Journals (Sweden)

    Meghan E. Kapp

    2016-01-01

    Full Text Available Cancer of the male breast is an uncommon event with metastases to the breast occurring even less frequently. Prostate carcinoma has been reported as the most frequent primary to metastasize to the breast; however, the reverse has not been previously reported. Herein, we present, for the first time, a case of breast carcinoma metastasizing to the prostate gland. Prostate needle core biopsy revealed infiltrative nests of neoplastic epithelioid cells, demonstrated by immunohistochemistry (IHC to be positive for GATA3 and ER and negative for PSA and P501S. A prostate cocktail by IHC study demonstrated lack of basal cells (p63 and CK903 and no expression of P501S. The patient’s previous breast needle core biopsy showed strong ER positivity and negative staining for PR and HER2. Similar to the prostate, the breast was negative for CK5/6, p63, and p40. This case demonstrates the importance of considering a broad differential diagnosis and comparing histology and IHC to prior known malignancies in the setting of atypical presentation or rare tumors.

  20. Diagnosing diseases of the thyroid gland by means of scintiscanning and puncture cytology taking into consideration the nodular goitre

    International Nuclear Information System (INIS)

    Eitel, M.

    1981-01-01

    This paper contains the results of scintigraphical and puncture-cytological examinations carried out during an observation period of appr. 3 years on 548 patients with goiters from the Upper-Bavarien endemis region. In total, we had 484 thyroid gland scintigrams which showed 335 uninodular, 71 multinodular, and 78 diffuse goiters. The 335 solitary nodular goiters were allocated 278 cold, 36 warm, and 18 hot nodes; in three cases, the scintigram could not be assessed due to exogenous iodine contamination. In the 71 multinodular goiters, we found 118 cold, 28 warm, and 9 hot nodes. Cytological findings were established in 548 patients. In 484 cases, the findings were negative, in 19 cases suspicious, and in 17 cases positive. The efficiency of cytological diagnosis of malignant tumours can be stated to be 87.5%. The rate of falsely negative smears was 12.5%; cytologically, in 10.9% of the preparations falsely suspicious diagnoses were established, and in 1.6% the diagnoses were falsely positive. (orig./MG) [de

  1. Il nuovo reato di false comunicazioni sociali

    Directory of Open Access Journals (Sweden)

    Lorenzo Maria Corvucci

    2015-12-01

    Full Text Available The author examines the new offence of false social communication introduced by the Italian law dated 27 may 2015 n.69 in force from 14 June 2015. Considering the modifications added to the new offence of false accounting- basically explained to highlight the novum - the attention is paid on a specific major issue, previously discussed by the fifth section of the Italian Supreme Court competent in this matter after a few months from the moment the new law came in force. The questions applies to the fact whether the fraudulent evidence should remain to be punishable as the new discipline has limited the object of the criminal conduct only to “material relevant facts which are untrue” or to the omission of material relevant facts whose communication is imposed by the law regulating the economic situation, the assets and financial position of the company or of the group to which the company belongs. In this way any reference to the evaluations contained in the text previously in force is eliminated. Omissive conduct is the new definition recalling the two previous rules (art. 2621 and 2622 of the Italian civil code.

  2. High confidence in falsely recognizing prototypical faces.

    Science.gov (United States)

    Sampaio, Cristina; Reinke, Victoria; Mathews, Jeffrey; Swart, Alexandra; Wallinger, Stephen

    2018-06-01

    We applied a metacognitive approach to investigate confidence in recognition of prototypical faces. Participants were presented with sets of faces constructed digitally as deviations from prototype/base faces. Participants were then tested with a simple recognition task (Experiment 1) or a multiple-choice task (Experiment 2) for old and new items plus new prototypes, and they showed a high rate of confident false alarms to the prototypes. Confidence and accuracy relationship in this face recognition paradigm was found to be positive for standard items but negative for the prototypes; thus, it was contingent on the nature of the items used. The data have implications for lineups that employ match-to-suspect strategies.

  3. The metapleural gland of ants

    DEFF Research Database (Denmark)

    Yek, Sze Huei; Mueller, Ulrich G

    2011-01-01

    The metapleural gland (MG) is a complex glandular structure unique to ants, suggesting a critical role in their origin and ecological success. We synthesize the current understanding of the adaptive function, morphology, evolutionary history, and chemical properties of the MG. Two functions......-compressible invagination of the integument and the secretion is thought to ooze out passively through the non-closable opening of the MG or is groomed off by the legs and applied to target surfaces. MG loss has occurred repeatedly among the ants, particularly in the subfamilies Formicinae and Myrmicinae, and the MG...... is more commonly absent in males than in workers. MG chemistry has been characterized mostly in derived ant lineages with unique biologies (e.g. leafcutter ants, fire ants), currently precluding any inferences about MG chemistry at the origin of the ants. A synthetic approach integrating functional...

  4. 19 CFR 111.32 - False information.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false False information. 111.32 Section 111.32 Customs... CUSTOMS BROKERS Duties and Responsibilities of Customs Brokers § 111.32 False information. A broker must... procure the giving of, any false or misleading information or testimony in any matter pending before the...

  5. Association of Parathyroid Gland Biopsy Excision Technique With Ex Vivo Radiation Counts During Radioguided Parathyroid Surgery.

    Science.gov (United States)

    Hinson, Andrew M; Lawson, Bradley R; Franco, Aime T; Stack, Brendan C

    2017-06-01

    Parathyroid biopsy represents a means for normal and hyperfunctional glands to be distinguished intraoperatively. However, no data exist to guide surgeons regarding how much of a parathyroid gland must be biopsied to satisfy the 20% rule. To quantify the relative proportion of a hyperfunctional parathyroid gland that must be evaluated with the gamma probe to satisfy the 20% rule. A retrospective review of surgical data for 24 consecutive patients (16 women, 18 men; mean [SD] age, 66.6 [10] years; range, 51-83 years) who underwent surgery for primary hyperparathyroidism between May and October, 2015, in a tertieary academic medical center. Extirpated parathyroid glands were sectioned into parallel or pie-shaped biopsies and evaluated ex vivo with a gamma probe to determine what percentage of a hyperfunctional gland must be sampled to meet the Norman 20% rule. The hypothesis was formulated during data collection. In total, 253 ex vivo biopsy specimens were obtained from 33 surgically removed parathyroid glands. Parathyroid biopsies satisfied the 20% rule with an accuracy that depended on the relative proportion of the parent gland represented: half or more (96.6%; 95% CI, 91.7%-100.0%), a quarter to one-half (87.0%; 95% CI, 79.3%-94.7%), less than a quarter (63.6%; 95% CI, 54.5%-72.8%). When less than a quarter of the gland was removed, pie-shaped biopsies were more likely to satisfy the 20% rule compared with parallel biopsies of the same weight (78.4% vs 56.2%; absolute difference, 22.2%; 95% CI, 4.7%-39.7%). Unless half of a parathyroid gland is biopsied during radioguided parathyroidectomy, the 20% rule cannot reliably rule out the presence of a hyperfunctional parathyroid lesion. Pie-shaped biopsies originating from the center of the gland are associated with a lower rate of false-negative results compared with peripheral biopsies of similar size. Pie-shaped biopsies and biopsy of half or more of each nonexcised parathyroid gland for ex vivo counts may increase

  6. Bioengineered Lacrimal Gland Organ Regeneration in Vivo

    Directory of Open Access Journals (Sweden)

    Masatoshi Hirayama

    2015-07-01

    Full Text Available The lacrimal gland plays an important role in maintaining a homeostatic environment for healthy ocular surfaces via tear secretion. Dry eye disease, which is caused by lacrimal gland dysfunction, is one of the most prevalent eye disorders and causes ocular discomfort, significant visual disturbances, and a reduced quality of life. Current therapies for dry eye disease, including artificial tear eye drops, are transient and palliative. The lacrimal gland, which consists of acini, ducts, and myoepithelial cells, develops from its organ germ via reciprocal epithelial-mesenchymal interactions during embryogenesis. Lacrimal tissue stem cells have been identified for use in regenerative therapeutic approaches aimed at restoring lacrimal gland functions. Fully functional organ replacement, such as for tooth and hair follicles, has also been developed via a novel three-dimensional stem cell manipulation, designated the Organ Germ Method, as a next-generation regenerative medicine. Recently, we successfully developed fully functional bioengineered lacrimal gland replacements after transplanting a bioengineered organ germ using this method. This study represented a significant advance in potential lacrimal gland organ replacement as a novel regenerative therapy for dry eye disease. In this review, we will summarize recent progress in lacrimal regeneration research and the development of bioengineered lacrimal gland organ replacement therapy.

  7. Primary parotid gland lymphoma: a case report

    Directory of Open Access Journals (Sweden)

    Paraskevas Katsaronis

    2011-08-01

    Full Text Available Abstract Introduction Mucosa associated lymphoid tissue lymphomas are the most common lymphomas of the salivary glands. The benign lymphoepithelial lesion is also a lymphoproliferative disease that develops in the parotid gland. In the present case report, we describe one case of benign lymphoepithelial lesion with a subsequent low transformation to grade mucosa associated lymphoid tissue lymphoma appearing as a cystic mass in the parotid gland. Case presentation A 78-year-old Caucasian female smoker was referred to our clinic with a non-tender left facial swelling that had been present for approximately three years. The patient underwent resection of the left parotid gland with preservation of the left facial nerve through a preauricular incision. The pathology report was consistent with a low-grade marginal-zone B-cell non-Hodgkin lymphoma (mucosa associated lymphoid tissue lymphoma following benign lymphoepithelial lesion of the gland. Conclusions Salivary gland mucosa associated lymphoid tissue lymphoma should be considered in the differential diagnosis of cystic or bilateral salivary gland lesions. Parotidectomy is recommended in order to treat the tumor and to ensure histological diagnosis for further follow-up planning. Radiotherapy and chemotherapy should be considered in association with surgery in disseminated forms or after removal.

  8. Comparison of different deep learning approaches for parotid gland segmentation from CT images

    Science.gov (United States)

    Hänsch, Annika; Schwier, Michael; Gass, Tobias; Morgas, Tomasz; Haas, Benjamin; Klein, Jan; Hahn, Horst K.

    2018-02-01

    The segmentation of target structures and organs at risk is a crucial and very time-consuming step in radiotherapy planning. Good automatic methods can significantly reduce the time clinicians have to spend on this task. Due to its variability in shape and often low contrast to surrounding structures, segmentation of the parotid gland is especially challenging. Motivated by the recent success of deep learning, we study different deep learning approaches for parotid gland segmentation. Particularly, we compare 2D, 2D ensemble and 3D U-Net approaches and find that the 2D U-Net ensemble yields the best results with a mean Dice score of 0.817 on our test data. The ensemble approach reduces false positives without the need for an automatic region of interest detection. We also apply our trained 2D U-Net ensemble to segment the test data of the 2015 MICCAI head and neck auto-segmentation challenge. With a mean Dice score of 0.861, our classifier exceeds the highest mean score in the challenge. This shows that the method generalizes well onto data from independent sites. Since appropriate reference annotations are essential for training but often difficult and expensive to obtain, it is important to know how many samples are needed to properly train a neural network. We evaluate the classifier performance after training with differently sized training sets (50-450) and find that 250 cases (without using extensive data augmentation) are sufficient to obtain good results with the 2D ensemble. Adding more samples does not significantly improve the Dice score of the segmentations.

  9. Thyroid Gland in Patients with Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    B T Turumhambetova

    2009-09-01

    Full Text Available The purpose of our study was to investigate the main parameters of thyroid status in patients with rheumatoid arthritis (RA, as well as particularities of course of this disease depending on of thyroid gland function disorder. Materials and methods. 52 women with RA were examined. The first group consisted of 11 women with subclinical and manifestive hypothyroidism the second one 41 women without thyroid gland function disorder. The group comparison was conducted on main indexes of thyroid gland condition the hormon level, AT-TPO, ultrasonic data, as well as clinical and laboratory RA data. Results. In women with hypothyroidism the systemic manifestations of RA were more often truely diagnosed; DAS28 indexes, ESR, the number ot swollen joints were higher. The high level ot AT-TPO was diagnosed in 54,55% – I group and in 31,7% – II group TTG level was really less in patients receiving synthetic glycocorticoids. Small thyroid gland volume was diagnosed in 23,07% of examined patients. The thyroid gland status indexes in them did not differ from patients with normal thyroid gland volume. Reliable increasing of the peripheral resistance index was revealed in lower thyroid artery according to the ultrasonic study data under the reduced thyroid gland size. Conclusions. High incidence of hypothyroidism and AT-TPO carriage in RA was revealed. Hypothyroidism development is accompanied by high clinic-laboratory RA activity. The reduction of the thyroid gland volumes in RA is possibly stipulated not only by autoimmunal pathology, but also chronic ischemia of the organ in the conditions of immune-complex vasculitis and early atherosclerosis. The TTG level in patients with RA is defined not only by pathology of the thyroid gland, but glycocorticoid therapy as well.

  10. Lymphoma type MALT of the parotid gland

    International Nuclear Information System (INIS)

    Frometa Neirai, Carlos; Gonzalez Gomez, Juan Manuel; Arredondo Lopez, Miguel

    2010-01-01

    The lymphomas type MALT or the mucosa-associated lymphoid tissue, are the most recent variety of non-Hodgkin lymphomas present mainly in the gastric mucosa associated with Helycobacter pylori infection and in the thyroid gland in relation to Hashimoto's thyroiditis. Frequently the origin of this lesion can't be determined only by cytology study, thus it is necessary the histopathology analysis for a definitive diagnosis in most cases. Present paper includes the case of male patient with bilateral volume increase of both parotid glands and a diagnosis cytopathological of a benign lymphoepithelial process and the development of a type MALT lymphoma in relation to the right parotid gland. (author)

  11. Hydatid disease of the submandibular gland

    International Nuclear Information System (INIS)

    Ullah, N.; Yousaf, N.

    2001-01-01

    Echinococcosis is a tissue infection of the human caused by the larval stage of echinococcus granulosus or E. multilocularis. Hydatid cyst of the head and neck region is uncommon and the involvement of salivary glands, especially the submandibular gland, is very rare. A case of submandibular gland hydatid cyst is reported in this article, in a patient who was presented with swelling of this area of three months' duration. Examination revealed a soft, non-tender, mobile mass measuring 6x4 cm. Chest X-ray and abdominal ultrasonography were normal. Excision of the whole mass was performed and pathological examination confirmed the fine needle aspiration cytology report. (author)

  12. [Salivary gland drainage into the thyroglossal duct].

    Science.gov (United States)

    Siem, G; Natvig, K; Kolbenstvedt, A; Lømo, J

    2001-01-20

    Failure in regression of the thyroglossal duct is one of the most common reasons for midline swellings in the neck. Several authors have described recurrent thyroglossal duct remnants with persisting draining sinuses. However, few have described accessory salivary glands that drain into the thyroglossal duct. In this article we report two such cases with midline salivary glands in the floor of the mouth. These two patients were subsequently successfully treated with radical tissue resection in the area between the hyoid bone and foramen cecum. Preoperative fistulography or sinography was useful to demonstrate the ductal ramification of the salivary glands, and use of methylene blue during surgery proved of significant value for the result.

  13. Motivated reconstruction: The effect of brand commitment on false memories.

    Science.gov (United States)

    Montgomery, Nicole Votolato; Rajagopal, Priyali

    2018-06-01

    Across 5 studies, we examine the effect of prior brand commitment on the creation of false memories about product experience after reading online product reviews. We find that brand commitment and the valence of reviews to which consumers are exposed, interact to affect the incidence of false memories. Thus, highly committed consumers are more susceptible to the creation of false experience memories on exposure to positive versus negative reviews, whereas low commitment consumers exhibit similar levels of false memories in response to both positive and negative reviews. Further, these differences across brand commitment are attenuated when respondents are primed with an accuracy motivation, suggesting that the biasing effects of commitment are likely because of the motivation to defend the committed brand. Finally, we find that differences in false memories subsequently lead to differences in intentions to spread word-of-mouth (e.g., recommend the product to friends), suggesting that the consequences of false product experience memories can be significant for marketers and consumers. Our findings contribute to the literatures in false memory and marketing by documenting a motivated bias in false memories because of brand commitment. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  14. Discriminating between true-positive and false-positive clinical mastitis alerts from automatic milking systems

    NARCIS (Netherlands)

    Steeneveld, W.; Gaag, van der L.C.; Ouweltjes, W.; Mollenhorst, H.; Hogeveen, H.

    2010-01-01

    Automatic milking systems (AMS) generate alert lists reporting cows likely to have clinical mastitis (CM). Dutch farmers indicated that they use non-AMS cow information or the detailed alert information from the AMS to decide whether to check an alerted cow for CM. However, it is not yet known to

  15. Bartholin’s gland adenoma in a Saanen goat

    Directory of Open Access Journals (Sweden)

    Jessica Regina Moreira

    2017-12-01

    Full Text Available ABSTRACT: Tumors affecting Bartholin’s gland are considered rare in human medicine; there are few reports in the veterinary literature, with descriptions occurring only in cows. This article described the clinical and pathological findings associated with Bartholin’s gland adenoma in a goat. Clinically, a 7-year-old pregnant Saanen goat presented bilateral enlargement of the vulva that did not regress spontaneously after parturition. Grossly, these vulvar masses were multilobulated, contained cystic areas from which oozed a whitish fluid. Histopathology revealed an adenoma characterized by the proliferation of irregularly shaped neoplastic epithelial cells that formed tubular to glandular-like structures. These neoplastic cells demonstrated moderate anisokaryosis and evident nucleoli. The intratumoral proliferation index (PI was estimated by immunoreactivity with the protein ki-67. Further, the glandular-like structures produced a Periodic Acid-Schiff positive secretion. A diagnosis of Bartholin’s gland adenoma was established due to the anatomic location of the neoplastic growths, the histopathological features, and the PI of the tumor.

  16. Consistent absence of BRAF mutations in salivary gland carcinomas

    Directory of Open Access Journals (Sweden)

    Nooshin Mohtasham

    2017-06-01

    Full Text Available Introduction: Malignant salivary gland tumors are rare entities. Despite advances in surgery, radiation therapy and chemotherapy, the rate of the mortality and five-year survival has not been improved markedly over the last few decades. The activation of EGFR- RAS-RAF signaling pathway contributes to the initiation and progression of many human cancers, promising a key pathway for therapeutic molecules. Thus, the objective of this study was to evaluate BRAF mutations in salivary gland carcinomas. Methods: We designed PCR- RFLP (Polymerase Chain Reaction -Restriction Fragment Length Polymorphism and screened 50 salivary gland carcinomas (SGCs including mucoepidermoid carcinoma (MEC, adenoid cystic carcinoma (AdCC and polymorphous low grade adenocarcinoma (PLGA for the BRAF V600E mutation. Results: PCR-RFLP analyses demonstrated no mutation in BRAF exon 15 for SGC samples at position V600, which is the most commonly mutated site for BRAF in human cancer. Conclusions: According to our results SGCs didn’t acquire BRAF mutations that result in a constitutive activation of the signaling cascade downstream of EGFR, hence SGCs can be a good candidate for anti EGFR therapies.

  17. Cytokeratin expression in mouse lacrimal gland germ epithelium.

    Science.gov (United States)

    Hirayama, Masatoshi; Liu, Ying; Kawakita, Tetsuya; Shimmura, Shigeto; Tsubota, Kazuo

    2016-05-01

    The lacrimal gland secretes tear fluids that protect the ocular surface epithelium, and its dysfunction leads to dry eye disease (DED). The functional restoration of the lacrimal gland by engraftment of a bioengineered lacrimal gland using lacrimal gland germ epithelial cells has been proposed to cure DED in mice. Here, we investigate the expression profile of cytokeratins in the lacrimal gland germ epithelium to clarify their unique characteristics. We performed quantitative polymerase chain reaction (Q-PCR) and immunohistochemistry (IHC) analysis to clarify the expression profile of cytokeratin in the lacrimal gland germ epithelium. The mRNA expression of keratin (KRT) 5, KRT8, KRT14, KRT15, and KRT18 in the lacrimal gland germ epithelium was increased compared with that in mouse embryonic stem cells and the lacrimal gland germ mesenchyme, as analyzed by Q-PCR. The expression level of KRT15 increased in the transition from stem cells to lacrimal gland germ epithelium, then decreased as the lacrimal gland matured. IHC revealed that the expression set of these cytokeratins in the lacrimal gland germ epithelium was different from that in the adult lacrimal gland. The expression of KRT15 was observed in the lacrimal gland germ epithelium, and it segmentalized into some of the basal cells in the intercanulated duct in mature gland. We determined the expression profile of cytokeratins in the lacrimal gland epithelium, and identified KRT15 as a candidate unique cellular marker for the lacrimal gland germ epithelium. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Observations on the oesophageal glands in some Tanzanian anurans

    African Journals Online (AJOL)

    in Hyla, Rana, BUfo, Pelobates and Triturus more pep- sinogen was produced in these glands than in the gastric glands. The aim of the present study was to obtain data on the occurrence of oesophageal glands in selected anurans from Tanzania and to compare their structure with the better known gastric glands. Materials ...

  19. Lymphoepithelial cyst of the submandibular gland

    Directory of Open Access Journals (Sweden)

    A Saneem Ahamed

    2014-01-01

    Full Text Available Lymphoepithelial cysts are benign, slowly growing unilocular or multilocular lesions that appear in the head and neck. They are also called Branchial cyst. The head and neck sites are the salivary glands(more commonly parotid and rarely submandibular gland and the oral cavity (usually the floor of the mouth. there are various methods of investigation available today, of which Fine needle aspiration cytology (FNAC can be used to provide an immediate diagnosis of a lymphoepithelial cyst. The other investigations include, Ultrasonogram,and Computed tomography.It usually occurs due to the process of lymphocyte-induced cystic ductular dilatation and the confirmatory diagnosis is always made postoperatively by histopathological examination. The mainstay in the treatment of a lymphoepithelial cyst remains the surgical approach, which includes complete enucleation of the cyst along with total excision of the involved salivary gland. This is a report of a lymphoepithelial cyst involving the submandibular salivary gland and its management.

  20. The surgical management of lacrimal gland pseudotumors

    NARCIS (Netherlands)

    Mombaerts, I.; Schlingemann, R. O.; Goldschmeding, R.; Noorduyn, L. A.; Koornneef, L.

    1996-01-01

    PURPOSE: Lacrimal gland pseudotumors belong to the group of orbital pseudotumor. Systemic corticosteroids are advocated as the primary treatment of choice in orbital pseudotumor, but recurrent and refractory cases are commonly described. In this retrospective study, the authors evaluate alteerative

  1. Computed tomographic diagnosis of parotid gland tumor

    International Nuclear Information System (INIS)

    Matsunaga, Hitoki; Nishimura, Tadao; Takasu, Akihiko; Yagizawa, Mikio; Suzuki, Akio

    1983-01-01

    Investigation with CT has been performed on 20 cases of parotid gland tumors. The intravenous contrast enhancement method was performed in all cases. Six cases were examined by CT and simultaneous sialography. The results were as follows: 1) If and when the margin of the tumor was indistinct and irregular, malignancy was suspected. However, it was difficult to diagnose malignancy by CT examination only. 2) CT for parotid gland tumor was effective in indentifying invasion of tumor into the parapharyngeal space and intracranial space. 3) CT with simultaneous sialography was very effective in locating the parotid gland tumor. 4) CT of axial sections for parotid gland tumor was more reliable if coronaly sections are taken together. 5) CT of malignant and benign tumors were diffusely enhanced by the intravenous contrast enhancement method. However, this was not an indispensable method. (author)

  2. The labral gland on termite soldiers

    Czech Academy of Sciences Publication Activity Database

    Palma-Onetto, V.; Hošková, K.; Křížková, B.; Krejčířová, R.; Pflegerová, Jitka; Bubeníčková, F.; Plarre, R.; Dahlsjö, C. A. L.; Synek, J.; Bourguignon, T.; Sillam-Dusses, D.; Šobotník, J.

    2018-01-01

    Roč. 123, č. 3 (2018), s. 535-544 ISSN 0024-4066 Institutional support: RVO:60077344 Keywords : exocrine gland * hypopharynx * labrum Subject RIV: ED - Physiology OBOR OECD: Entomology Impact factor: 2.288, year: 2016

  3. Salivary gland enlargement during oesophageal stricture dilatation.

    OpenAIRE

    Martin, D.

    1980-01-01

    A case of recurrent salivary gland enlargement occurring during fibreoptic oesophagoscopy and oesophageal stricture dilatation with Eder-Puestow dilators is described. The genesis of this condition is discussed and its transient and usually benign nature emphasized.

  4. Salivary gland doses from dental radiographic exposures

    International Nuclear Information System (INIS)

    Hoshi, Masaharu; Kato, Kazuo; Wada, Takuro; Antoku, Shigetoshi; Russell, W.J.

    1989-01-01

    Salivary gland doses incurred during dental radiography were measured by phantom dosimetry, and these dose data and data obtained during a two-week survey of Hiroshima and Nagasaki dental hospitals and clinics were used to estimate the respective doses to members of the populations of the two cities. The results obtained were used to supplement previously determined doses to the thyroid gland, lens, and pituitary gland from dental radiography. No significant differences in doses were observed by age, sex or city. Doses to the salivary glands during dental radiography are probably not sufficiently large to cause bias in assessments of atomic bomb survivors for late radiation effects. However, the steadily increasing use of dental radiography underscores the need for continued monitoring of dental radiography doses in the interests of these assessments. (author)

  5. [Autoimmune diseases of the thyroid gland].

    Science.gov (United States)

    Allelein, S; Feldkamp, J; Schott, M

    2017-01-01

    Autoimmune diseases of the thyroid gland are considered to be the most frequent cause of thyroid gland disorders. Autoimmune thyroid diseases consist of two subgroups: autoimmune thyroiditis (AIT) and Graves' disease. The AIT is the most common human autoimmune disease. Infiltration of the thyroid gland with cytotoxic T‑cells can lead to an initial thyrotoxicosis und during the course to hypothyroidism due to destruction of the thyroid gland. Substitution with Levothyroxine is indicated for manifest hypothyroidism and subclinical hypothyroidism with increased thyroid antibodies with the intention of normalizing the serum thyroid stimulating hormone (TSH). Graves' disease is characterized by the appearance of stimulating TSH receptor antibodies leading to hyperthyroidism. Endocrine ophthalmopathy may also occur. Ablative therapy with radioiodine therapy or thyroidectomy is administered to patients with Graves' disease without remission after at least 1 year of antithyroid drug therapy.

  6. Amyloidosis of the thyroid gland: ultrasonographic aspect

    International Nuclear Information System (INIS)

    Moya, M.I.; Vilas, I.; Menargues, M.A.; Hernandez, M.

    1998-01-01

    Subclinical amyloid infiltration of the thyroid gland is very common. However, amyloidosis rarely provokes thyroid symptoms. We describe a case of goiter due to secondary amyloidosis and review the characteristic ultrasound findings associated with this condition. (Author) 6 refs

  7. Osteopontin expression in salivary gland carcinomas

    DEFF Research Database (Denmark)

    Bjørndal, Kristine; Larsen, Stine R; Godballe, Christian

    2011-01-01

    J Oral Pathol Med (2010) Background:  In several cancer types, osteopontin (OPN) expression has been correlated with tumor progression and prognosis. Two earlier studies have examined OPN expression in salivary gland carcinomas with contradictory results. Methods:  One hundred and seventy......:  Osteopontin was expressed in all salivary gland carcinomas. Adenoid cystic carcinomas had the highest mean sum score (7.3) and a significantly higher proportion of carcinomas with high OPN sum score than both mucoepidermoid carcinoma and acinic cell carcinoma. Correlation of OPN expression with known...... prognostic factors in salivary gland carcinomas was insignificant. Conclusions:  Salivary gland carcinomas express OPN. The expression does not correlate with known prognostic factors....

  8. Displacement of the normal pituitary gland by sellar and juxtasellar tumours: surgical-MRI correlation and use in differential diagnosis

    International Nuclear Information System (INIS)

    Sumida, M.; Uozumi, T.; Yamanaka, M.; Mukada, K.; Arita, K.; Kurisu, K.; Satoh, H.; Ikawa, F.

    1994-01-01

    We compared the position of the normal pituitary gland as estimated by gadolinium (Gd)-DTPA-enhanced MRI, with its position at surgery in 40 patients with intra- and juxtasellar tumours: 22 pituitary adenomas, 4 craniopharyngiomas, 7 meningiomas, 2 germinomas, and 5 Rathke cleft cysts. In 37 of these, the normal gland showed more intense contrast enhancement than the adjacent tumour, from which it could be differentiated by Gd-DTPA-enhanced MRI, especially in the sagittal plane. The direction of displacement of the normal pituitary gland correlated well with tumour type, so that its position proved helpful in the differential diagnosis. The normal gland was typically displaced superiorly by pituitary adenomas, inferiorly by craniopharyngiomas, and anteriorly by germinomas. It showed variable displacement by Rathke cleft cysts, and was not usually displaced by meningiomas. (orig.)

  9. Radiation Treatment for Primary Adenocarcinoma of Bartholin Gland- A Case Report and Review of Literature

    International Nuclear Information System (INIS)

    Oh, Won Yong; Whang, In Soon

    1989-01-01

    A patient with primary adenocarcinoma of Bartholin gland is reported and the literatures relevant to this disease reviewed. Not only this disease is very rare but also primary carcinomas of Bartholin gland are misdiagnosed as cysts or abscesses in half of the cases, leading to considerable delay in diagnosis. And so, It was wasted long time before definitive therapy. However, because of a different clinical behavior, cancer of the Bartholin gland should be distinguished from other vulvar carcinomas. Histologically, squamous cell carcinoma and adenocarcinoma are the most common. Virtually all histologic types of Bartholin gland carcinoma metastasize to lymph node, bone, lung and liver in distant sites. The authors data and a review of the literature support the concept that radical vulvectomy with or without bilateral inguina1-femoral lymphadenectomy is required. On the other hand, except primary radiation treatment for small or medium sized cancers, the results obtained by radiation therapy in carcinoma of the vulva including Bartholin gland are generally discouraging. A role for postoperative adjuvant radiation therapy suggests because of high incidence of positive inguinal-femoral lymph nodes. In the near time, natural history and biological behavior of Bartholin gland cancer must be disclosed in detail. And also optimal treatment modality and prognostic factors shall be determine

  10. The nasus gland: a new gland in soldiers of Angularitermes (Termitidae, Nasutitermitinae).

    Science.gov (United States)

    Šobotník, Jan; Bourguignon, Thomas; Carrijo, Tiago F; Bordereau, Christian; Robert, Alain; Křížková, Barbora; Constantini, Joice P; Cancello, Eliana M

    2015-09-01

    Termites have developed many exocrine glands, generally dedicated to defence or communication. Although a few of these glands occur in all termite species, or represent synapomorphies of larger clades, others are morphological innovations of a single species, or a few related species. Here, we describe the nasus gland, a new gland occurring at the base of the nasus of Angularitermes soldiers. The nasus gland is composed of class 1, 2, and 3 secretory cells, a rare combination that is only shared by the sternal and tergal glands of some termites and cockroaches. The ultrastructural observations suggest that the secretion is produced by class 2 and 3 secretory cells, and released mostly by class 3 cells. The base of the nasus has a rough appearance due to numerous pits bearing openings of canals conducting the secretion from class 3 secretory cells to the exterior. We tentatively assign a defensive function to the nasus gland, although further research is needed to confirm this function. Although the gland is described only from species of Angularitermes, other genera of Nasutitermitinae also present a rough nasus base, suggesting the presence of a similar, possibly homologous, gland. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Disfluent presentations lead to the creation of more false memories.

    Science.gov (United States)

    Sanchez, Christopher A; Naylor, Jamie S

    2018-01-01

    The creation of false memories within the Deese-Roediger-McDermott (DRM) paradigm has been shown to be sensitive to many factors such as task instructions, participant mood, or even presentation modality. However, do other simple perceptual differences also impact performance on the DRM and the creation of false memories? This study explores the potential impact of changes in perceptual disfluency on DRM performance. To test for a potential influence of disfluency on false memory creation, participants viewed lists under either perceptually disfluent conditions or not. Results indicated that disfluency did significantly impact performance in the DRM paradigm; more disfluent presentations significantly increased the recall and recognition of unpresented information, although they did not impact recall or recognition of presented information. Thus, although disfluency did impact performance, disfluency did not produce a positive benefit related to overall task performance. This finding instead suggests that more disfluent presentations can increase the likelihood that false memories are created, and provide little positive performance benefit.

  12. An analysis of preoperative localization of parathyroid glands in hyperparathyroidism associated with thyroid diseases

    International Nuclear Information System (INIS)

    Komatsu, Makoto; Inoue, Kazuaki; Itoh, Atsuko.

    1996-01-01

    Recently hyperparathyroidism associated with some thyroid diseases, especially nonmedually thyroid carcinoma has been payed attention to. In this study we analyzed 12 cases of hyperparathyroidism (6 cases independent of thyroid diseases and 6 cases associated with thyroid diseases) and estimated the affect of association with thyroid diseases on the preoperative localization of the parathyroid glands. The results of preoperative localization of the parathyroid glands in cases independent of thyroid diseases were relatively satisfactory. On the other hand, the preoperative localization in cases associated with thyroid diseases came to false result in about half of them. It was far from satisfactory. Association of thyroid diseases strongly affected the preoperative localization of the parathyroid glands in hyperparathyroidism. Conventional imaging such as ultrasonography, CT, MRI and 201 Tl- 99m TC subtraction scintigraphy alone were not satisfactory. Now 99m Tc-MIBI scintigraphy is expected to be one of reliable imaging methods for progress in the preoperative localization. (author)

  13. Morphology and diversity of exocrine glands in lepidopteran larvae.

    Science.gov (United States)

    Vegliante, Francesca; Hasenfuss, Ivar

    2012-01-01

    The morphology of 21 exocrine glands and 13 supposedly exocrine structures recorded for lepidopteran larvae is reviewed. The epitracheal glands, for which a double role (exocrine and endocrine) has been demonstrated, are examined as well. Function is well known for at least 8 glands but completely unknown for 6 glands, for 10 putative glandular structures, and for the exocrine component of the epitracheal glands. Functional studies on the remaining structures are insufficient; in some cases (mandibular gland and adenosma) homologous glands may play a different role depending on the species, and only a few taxa have been examined. The secretions of 13 glandular types have been analyzed chemically. The histology of 11 glands is known at the ultrastructural level, whereas that of 6 glands and 7 putative glandular structures is completely unknown. Comparative anatomical studies of the osmeterium, adenosma, and Verson's glands may yield useful information for phylogenetic reconstructions. Copyright © 2012 by Annual Reviews. All rights reserved.

  14. Attitude Importance and the False Consensus Effect.

    Science.gov (United States)

    Fabrigar, Leandre R.; Krosnick, Jon A.

    1995-01-01

    Explores the possibility that importance may regulate the magnitude of the false consensus effect. Analysis revealed a strong false consensus effect but no reliable relation between its magnitude and attitude importance. Results contradict assumptions that the false consensus effect arises from attitudes that directly or indirectly influence…

  15. Histopathological audit of salivary gland neoplasms

    International Nuclear Information System (INIS)

    Memon, J.M.; Sheikh, B.

    2014-01-01

    Salivary gland neoplasms are uncommon but important presentation to general surgeons. Objective: To analyze the relative frequency and distribution of Salivary gland neoplasms in our division. Setting: Department of surgery and pathology, Peoples Medical University hospital and GMMMC hospital Sukkur. Study design: Descriptive (case series) Subjects and methods: A total of 40 patients registered for salivary gland tumors from oct 2008 to 0ct 2013 were included in the study. A thorough history, clinical examination, routine haematological and biochemical studies were done in all patients. FNAC was done in all cases. All patients were subjected to surgical intervention on standard rules. Each resected specimen was sent for histopathology. Information about age, gender and tumor location was obtained from clinical record and frequency of different neoplasms was studied from histopathological report. All data was collected on especially designed proforma. Data analysis was done using spss version 17. Results: A total of 40 patients were registered for salivary gland neoplasms. 28 patients (70%) had parotid lesions, 10 patients (25%) had submandibular gland involvement and 2 patients ( 5%) had minor salivary gland tumors. Patients were between 15 - 80 years of age( mean age =34.7 years) 24 patients(60%) were male and 16 (40%) were female,with male to female ratio of 1.5:1.32 . 22 (80%) had benign lesions and 8 patients (20%) had malignant lesions. Pleomorphic adenoma was the most common benign tumor affecting the parotid gland. Adenocarcinoma represented as the most prevelant parotid malignancy. Benign neoplasms occurred in third and fourth decades of life and malignant neoplasms were diagnosed in sixth and seventh decades of life. Conclusion:Salivary gland neoplasms are uncommon but they have occasioned much interest and debate because of broad histological spectrum. The data presented in this study is corroborated with most of the studied literature worldwide. (author)

  16. Pheromones and exocrine glands in Isoptera.

    Science.gov (United States)

    Costa-Leonardo, Ana Maria; Haifig, Ives

    2010-01-01

    Termites are eusocial insects that have a peculiar and intriguing system of communication using pheromones. The termite pheromones are composed of a blend of chemical substances and they coordinate different social interactions or activities, including foraging, building, mating, defense, and nestmate recognition. Some of these sociochemicals are volatile, spreading in the air, and others are contact pheromones, which are transmitted by trophallaxis and grooming. Among the termite semiochemicals, the most known are alarm, trail, sex pheromones, and hydrocarbons responsible for the recognition of nestmates. The sources of the pheromones are exocrine glands located all over the termite body. The principal exocrine structures considered pheromone-producing glands in Isoptera are the frontal, mandibular, salivary or labial, sternal, and tergal glands. The frontal gland is the source of alarm pheromone and defensive chemicals, but the mandibular secretions have been little studied and their function is not well established in Isoptera. The secretion of salivary glands involves numerous chemical compounds, some of them without pheromonal function. The worker saliva contains a phagostimulating pheromone and probably a building pheromone, while the salivary reservoir of some soldiers contains defensive chemicals. The sternal gland is the only source of trail-following pheromone, whereas sex pheromones are secreted by two glandular sources, the sternal and tergal glands. To date, the termite semiochemicals have indicated that few molecules are involved in their chemical communication, that is, the same compound may be secreted by different glands, different castes and species, and for different functions, depending on the concentration. In addition to the pheromonal parsimony, recent studies also indicate the occurrence of a synergic effect among the compounds involved in the chemical communication of Isoptera. Copyright © 2010 Elsevier Inc. All rights reserved.

  17. CT of submandibular gland sialolithiasis

    International Nuclear Information System (INIS)

    Avrahami, E.; Englender, M.; Chen, E.; Shabtay, D.; Katz, R.; Harell, M.

    1996-01-01

    We emphasise the importance of high-resolution CT with reconstruction in the demonstration of submandibular gland (SMG) sialolithiasis and its role in monitoring treatment. We studied 76 patients with swollen and tender SMG, some with fever. They underwent conventional radiography, sonography (US) and high-resolution CT with reconstructions. Conventional radiographs demonstrated single stones in 29 patients. Axial CT, before reconstructions, demonstrated single stones in 63 patients and multiple stones in another 5. Following CT reconstructions, multiple stones were demonstrated in 37 patients. On US stones were diagnosed in only 33 patients, and multiple stones in only 1. All 68 patients with stones shown on imaging and 2 without stones underwent surgery, with good clinical results. Total removal of the SMG and its duct was performed in patients with multiple stones, chronic inflammatory changes in the SMG, or a solitary stone in the SMG or deep in the duct. A small incision for removal of a solitary stone in the distal aspects of Wharton's duct was performed in 15 patients, with excellent clinical results. Another 14 patients with multiple salivary glad stones, diagnosed on CT reconstructions, did not improve following this procedure and needed further surgery; clinical improvement occurred following excision of the SMG and Wharton's duct. Histological examination in all of these confirmed the presence of additional stones. Conservative anti-inflammatory treatment was recommended for 6 patients in whom CT reconstructions did not demonstrate stones. (orig.)

  18. [Solitary hyperfunctioning thyroid gland carcinomas].

    Science.gov (United States)

    Zivaljevic, V; Zivic, R; Diklic, A; Krgovic, K; Kalezic, N; Vekic, B; Stevanovic, D; Paunovic, I

    2011-08-01

    Thyroid gland carcinomas usually appear as afunctional and hypofunctional lesions on thyroid scintigrams, but some rare cases of thyroid carcinoma with scintigraphic hyperfunctional lesions have also been reported. The aim of our retrospective study was to elucidate the frequency of carcinomas in patients operated for solitary hyperfunctional thyroid nodules and to represent their demographic and clinical features. During one decade (1997/2006), 308 patients were operated for solitary hyperfunctional thyroid nodules in the Centre for Endocrine Surgery in Belgrade. Malignancy was revealed in 9 cases (about 3 %) by histopathological examination. In 6 cases papillary microcarcinomas were found adjacent to dominant hyperfunctional adenomas, while in 3 cases (about 1 %) real hyperfunctional carcinomas were confirmed. Follicular carcinoma was diagnosed in 2 cases and papillary carcinoma in one. All 3 patients were preoperatively hyperthyroid. In both patients with follicular carcinoma we performed lobectomies. In the third case we carried out a total thyroidectomy considering the intraoperative frozen section finding of a papillary carcinoma. According to our results the frequency of solitary hyperfunctioning thyroid carcinomas is about 1 %, so that the possibility that a hyperfunctional nodule is malignant should be considered in the treatment of such lesions. © Georg Thieme Verlag KG Stuttgart ˙ New York.

  19. Voting experiments: Bandwagon voting or false-consensus effect?

    OpenAIRE

    Ivo Bischoff; Henrik Egbert

    2008-01-01

    In an experiment designed to test for expressive voting, Tyran (JPubEc 2004) found a strong positive correlation between the participants' approval for a proposal to donate money for charity and their expected approval rate for fellow voters. This phenomenon can be due to bandwagon voting or a false consensus effect. The social science literature reports both effects for voting decisions. Replicating Tyran's experiment and adding new treatments, we provide evidence for a false consensus effec...

  20. Development of lacrimal gland spheroids for lacrimal gland tissue regeneration.

    Science.gov (United States)

    Massie, Isobel; Spaniol, Kristina; Barbian, Andreas; Geerling, Gerd; Metzger, Marco; Schrader, Stefan

    2018-04-01

    Severe dry eye syndrome resulting from lacrimal gland (LG) dysfunction can cause blindness, yet treatments remain palliative. In vitro reconstruction of LG tissue could provide a curative treatment. We aimed to combine epithelial cells with endothelial cells and mesenchymal stem cells (MSCs) to form a 3D functional unit. Epithelial cells and MSCs were isolated from porcine LG; endothelial cells were isolated from human foreskin. MSCs were characterised (flow cytometry and differentiation potential assays). All 3 cell types were combined on Matrigel and spheroid formation observed. Spheroids were characterised [immunohistochemistry (IHC) and transmission electron microscopy] and function assessed (β-hexosaminidase assay). Spheroids were transferred to decellularised jejunum (SIS-Muc) in dynamic cultures for 1 week before further characterisation. MSCs did not express CD31 but expressed CD44 and CD105 and differentiated towards osteogenic and adipogenic lineages. Spheroids formed on Matrigel within 18 hr, contracting to ~10% of the well area (p function was increased in spheroids cf. monolayer controls (p function (p < .05), viability (p < .05), and proliferation decreased, whilst apoptosis increased. On SIS-Muc under dynamic culture, however, spheroids continued to proliferate to repopulate SIS-Muc. IHC revealed LG epithelial cells coexpressing pan-cytokeratin and lysozyme, as well as endothelial cells and MSCs and cells remained capable of responding to carbachol (p < .05). These spheroids could form the basis of a regenerative medicine treatment approach for dry eye syndrome. In vivo studies are required to evaluate this further. Copyright © 2017 John Wiley & Sons, Ltd.

  1. [Surgical management of minor salivary gland tumors].

    Science.gov (United States)

    Zhou, Liang; Chen, Xiaoling; Huang, Weiting; Li, Kelan; Zhang, Xiaotong; Wang, Wei

    2007-11-01

    To study the clinical features of minor salivary gland tumors and to discuss the treatment modalities for these tumors. Retrospective analysis of 54 cases with minor salivary gland tumor operated in our hospital from 1997 to 2004. Among 54 cases with minor salivary gland tumors in this series, 16 patients lost of follow up. Among the remaining 38 patients, 2 patients with nasal cavity adenoid cystic carcinoma died of tumor recurrence 2 and 3 years after the surgery respectively, one patient with laryngeal myoepithelial carcinoma died of tumor recurrence 3 years after the surgery and one patient with paranasal sinus mucoepidermoid carcinoma died of recurrence 17 months after the surgery. Two patients with paranasal sinus adenoid cystic carcinoma recurred after the primary surgery and were survived without tumor after salvage surgery. The other patients survived with no tumor recurrence. While different histopathology of minor salivary gland tumors were found in this group, malignant tumors were predominant, accounting for 81.4%. The choice of treatment for minor salivary gland tumors depends upon the location and the histopathology of the tumors. The treatment policy for benign tumors is simple tumor excision, while that for malignant tumors is surgery combined with pre- or post-operative radiation therapy. Complete surgical resection of tumor masses and tumor free margin is essential for successful treatment of malignant minor salivary gland tumors.

  2. Lacrimal Gland Radiosensitivity in Uveal Melanoma Patients

    International Nuclear Information System (INIS)

    Muller, Karin; Nowak, Peter J.C.M.; Naus, Nicole; Pan, Connie de; Santen, Cornelis A. van; Levendag, Peter; Luyten, Gre P.M.

    2009-01-01

    Purpose: To find a dose-volume effect for inhomogeneous irradiated lacrimal glands. Methods and Materials: Between 1999 and 2006, 72 patients (42 men and 30 women) were treated with fractionated stereotactic radiotherapy in a prospective, nonrandomized clinical trial (median follow-up, 32 months). A total dose of 50 Gy was given on 5 consecutive days. The mean of all Schirmer test results obtained ≥6 months after treatment was correlated with the radiation dose delivered to the lacrimal gland. Also, the appearance of dry eye syndrome (DES) was related to the lacrimal gland dose distribution. Results: Of the 72 patients, 17 developed a late Schirmer value <10 mm; 9 patients developed DES. A statistically significant relationship was found between the received median dose in the lacrimal gland vs. reduced tear production (p = 0.000) and vs. the appearance of DES (p = 0.003), respectively. A median dose of 7 Gy/fraction to the lacrimal gland caused a 50% risk of low Schirmer results. A median dose of 10 Gy resulted in a 50% probability of DES. Conclusion: We found a clear dose-volume relationship for irradiated lacrimal glands with regard to reduced tear production and the appearance of DES.

  3. Iatrogenic causes of salivary gland dysfunction

    International Nuclear Information System (INIS)

    Schubert, M.M.; Izutsu, K.T.

    1987-01-01

    Saliva is important for maintaining oral health and function. There are instances when medical therapy is intended to decrease salivary flow, such as during general anesthesia, but most instances of iatrogenic salivary gland dysfunction represent untoward or unavoidable side-effects. The clinical expression of the salivary dysfunction can range from very minor transient alteration in saliva flow to a total loss of salivary function. The most common forms of therapy that interfere with salivation are drug therapies, cancer therapies (radiation or chemotherapy), and surgical therapy. These therapies can affect salivation by a number of different mechanisms that include: disruption of autonomic nerve function related to salivation, interference with acinar or ductal cell functions related to salivation, cytotoxicity, indirect effects (vasoconstriction/dilation, fluid and electrolyte balance, etc.), and physical trauma to salivary glands and nerves. A wide variety of drugs is capable of increasing or decreasing salivary flow by mimicking autonomic nervous system actions or by directly acting on cellular processes necessary for salivation: drugs can also indirectly affect salivation by altering fluid and electrolyte balance or by affecting blood flow to the glands. Ionizing radiation can cause permanent damage to salivary glands, damage that is manifest as acinar cell destruction with subsequent atrophy and fibrosis of the glands. Cancer chemotherapy can cause changes in salivation, but the changes are usually much less severe and only transient. Finally, surgical and traumatic injuries interfere with salivation because of either disruption of gland innervation or gross physical damage (or removal) of glandular tissue (including ducts)

  4. Recursive belief manipulation and second-order false-beliefs

    DEFF Research Database (Denmark)

    Braüner, Torben; Blackburn, Patrick Rowan; Polyanskaya, Irina

    2016-01-01

    it indicate that a more fundamental *conceptual change* has taken place? In this paper we extend Braüner's hybrid-logical analysis of first-order false-belief tasks to the second-order case, and argue that our analysis supports a version of the conceptual change position.......The literature on first-order false-belief is extensive, but less is known about the second-order case. The ability to handle second-order false-beliefs correctly seems to mark a cognitively significant step, but what is its status? Is it an example of *complexity only* development, or does...

  5. Avoiding the False Peaks in Correlation Discrimination

    International Nuclear Information System (INIS)

    Awwal, A.S.

    2009-01-01

    Fiducials imprinted on laser beams are used to perform video image based alignment of the 192 laser beams in the National Ignition Facility (NIF) of Lawrence Livermore National Laboratory. In many video images, matched filtering is used to detect the location of these fiducials. Generally, the highest correlation peak is used to determine the position of the fiducials. However, when the signal to-be-detected is very weak compared to the noise, this approach totally breaks down. The highest peaks act as traps for false detection. The active target images used for automatic alignment in the National Ignition Facility are examples of such images. In these images, the fiducials of interest exhibit extremely low intensity and contrast, surrounded by high intensity reflection from metallic objects. Consequently, the highest correlation peaks are caused by these bright objects. In this work, we show how the shape of the correlation is exploited to isolate the valid matches from hundreds of invalid correlation peaks, and therefore identify extremely faint fiducials under very challenging imaging conditions

  6. Macroscopic Study of the Isthmus of the Thyroid Gland in Bangladeshi People: A Postmortem Study

    Directory of Open Access Journals (Sweden)

    Fakhrul Amin Mohammad Hasanul Banna

    2017-01-01

    Full Text Available Background: The position and size of isthmus of thyroid gland varies considerably in human with age, sex, physiologic state, race and geographical location and sometimes the isthmus may be absent. So this study was designed to find out the macroscopic differences in isthmus of thyroid gland of different age and sex groups in Bangladeshi people. Objective: To record the macroscopic characteristics of isthmus of thyroid gland with advancing age in both sexes with a view to help establishing normal standard of Bangladeshi people. Materials and Methods: This descriptive cross-sectional study was carried out on 54 autopsied human thyroid glands aged 5 to 65 years. Thyroid glands were collected from unclaimed dead bodies autopsied in the morgue of Sylhet M. A. G. Osmani Medical College, Sylhet. The collected specimens were divided into groups –– A (20 years and below, B (21 to 50 years and C (50 years and above. All specimens were examined morphologically by careful gross dissection method. Results: The isthmus was absent in 5.56% cases. In most of the cases (35.29% it was against the 1st–4th tracheal rings. There was significant difference in length between Group A and Group C (p<0.05 and in breadth between Group A and Group C and between Group B and Group C (p<0.05. No significant difference was found in length, breadth and thickness of isthmus of the thyroid gland between males and females. Conclusion: The presence or absence, positional change and variation in gross dimension of isthmus of thyroid gland were evident in human. The macroscopic difference was found with increasing age but not with sex.

  7. Too Good to be False: Nonsignificant Results Revisited

    Directory of Open Access Journals (Sweden)

    Chris H. J. Hartgerink

    2017-03-01

    Full Text Available Due to its probabilistic nature, Null Hypothesis Significance Testing (NHST is subject to decision errors. The concern for false positives has overshadowed the concern for false negatives in the recent debates in psychology. This might be unwarranted, since reported statistically nonsignificant findings may just be ‘too good to be false’. We examined evidence for false negatives in nonsignificant results in three different ways. We adapted the Fisher test to detect the presence of at least one false negative in a set of statistically nonsignificant results. Simulations show that the adapted Fisher method generally is a powerful method to detect false negatives. We examined evidence for false negatives in the psychology literature in three applications of the adapted Fisher method. These applications indicate that (i the observed effect size distribution of nonsignificant effects exceeds the expected distribution assuming a null-effect, and approximately two out of three (66.7% psychology articles reporting nonsignificant results contain evidence for at least one false negative, (ii nonsignificant results on gender effects contain evidence of true nonzero effects, and (iii the statistically nonsignificant replications from the Reproducibility Project Psychology (RPP do not warrant strong conclusions about the absence or presence of true zero effects underlying these nonsignificant results. We conclude that false negatives deserve more attention in the current debate on statistical practices in psychology. Potentially neglecting effects due to a lack of statistical power can lead to a waste of research resources and stifle the scientific discovery process.

  8. Venom and Dufour's glands of the emerald cockroach wasp Ampulex compressa (Insecta, Hymenoptera, Sphecidae): structural and biochemical aspects.

    Science.gov (United States)

    Gnatzy, Werner; Michels, Jan; Volknandt, Walter; Goller, Stephan; Schulz, Stefan

    2015-09-01

    The digger wasp species Ampulex compressa produces its venom in two branched gland tubules. They terminate in a short common duct, which is bifurcated at its proximal end. One leg is linked with the venom reservoir, the other one extends to the ductus venatus. Each venom gland tubule possesses, over its entire length, a cuticle-lined central duct. Around this duct densely packed class 3 gland units each composed of a secretory cell and a canal cell are arranged. The position of their nuclei was demonstrated by DAPI staining. The brush border of the secretory cells surrounds the coiled end-apparatus. Venom is stored in a bladder like reservoir, which is surrounded by a thin reticulated layer of muscle fibres. The reservoir as a whole is lined with class 3 gland units. The tubiform Dufour's gland has a length of about 350 μm (∅ 125 μm) only and is surrounded by a network of pronounced striated muscle fibres. The glandular epithelium is mono-layered belonging to the class 1 type of insect epidermal glands. The gland cells are characterized by conspicuous lipid vesicles. Secretion of material via the gland cuticle into the gland lumen is apparent. Analysis of the polypeptide composition demonstrated that the free gland tubules and the venom reservoir contain numerous proteins ranging from 3.4 to 200 kDa. The polypeptide composition of the Dufour's gland is completely different and contains no lectin-binding glycoproteins, whereas a dominant component of the venom droplets is a glycoprotein of about 80 kDa. Comparison of the venom reservoir contents with the polypeptide pattern of venom droplets revealed that all of the major proteinaceous constituents are secreted. The secreted venom contains exclusively proteins present in the soluble contents of the venom gland. The most abundant compound class in the Dufour's gland consisted of n-alkanes followed by monomethyl-branched alkanes and alkadienes. Heptacosane was the most abundant n-alkane