WorldWideScience

Sample records for generation-atomic fluorescence detection

  1. Antimony speciation in soils: improving the detection limits using post-column pre-reduction hydride generation atomic fluorescence spectroscopy (HPLC/pre-reduction/HG-AFS).

    Science.gov (United States)

    Quiroz, Waldo; Olivares, David; Bravo, Manuel; Feldmann, Jorg; Raab, Andrea

    2011-04-15

    HG-AFS is highly sensitive and low cost detection system and its use for antimony chemical speciation coupled to HPLC is gaining popularity. However speciation analysis in soils is strongly hampered because the most efficient extractant reported in the literature (oxalic acid) strongly inhibits the generation of SbH(3) by Sb(V), the major species in this kind of matrix, severely affecting its detection limits. The purpose of this research is to reduce the detection limit of Sb(V), by using a post column on-line reduction system with l-cysteine reagent (HPLC/pre-reduction/HG-AFS). The system was optimized by experimental design, optimum conditions found were 2% (w/v) and 10°C temperature coil. Detection limits of Sb(V) and Sb(III) in oxalic acid (0.25 mol L(-1)) were improved from 0.3 and 0.1 μg L(-1) to 0.07 and 0.07 μg L(-1), respectively. The methodology developed was applied to Chilean soils, where Sb(V) was the predominant species. Copyright © 2011 Elsevier B.V. All rights reserved.

  2. [Research on optimization of mathematical model of flow injection-hydride generation-atomic fluorescence spectrometry].

    Science.gov (United States)

    Cui, Jian; Zhao, Xue-Hong; Wang, Yan; Xiao, Ya-Bing; Jiang, Xue-Hui; Dai, Li

    2014-01-01

    Flow injection-hydride generation-atomic fluorescence spectrometry was a widely used method in the industries of health, environmental, geological and metallurgical fields for the merit of high sensitivity, wide measurement range and fast analytical speed. However, optimization of this method was too difficult as there exist so many parameters affecting the sensitivity and broadening. Generally, the optimal conditions were sought through several experiments. The present paper proposed a mathematical model between the parameters and sensitivity/broadening coefficients using the law of conservation of mass according to the characteristics of hydride chemical reaction and the composition of the system, which was proved to be accurate as comparing the theoretical simulation and experimental results through the test of arsanilic acid standard solution. Finally, this paper has put a relation map between the parameters and sensitivity/broadening coefficients, and summarized that GLS volume, carrier solution flow rate and sample loop volume were the most factors affecting sensitivity and broadening coefficients. Optimizing these three factors with this relation map, the relative sensitivity was advanced by 2.9 times and relative broadening was reduced by 0.76 times. This model can provide a theoretical guidance for the optimization of the experimental conditions.

  3. Antimony speciation analysis in sediment reference materials using high-performance liquid chromatography coupled to hydride generation atomic fluorescence spectrometry

    International Nuclear Information System (INIS)

    Potin-Gautier, M.; Pannier, F.; Quiroz, W.; Pinochet, H.; Gregori, I. de

    2005-01-01

    This work presents the development of suitable methodologies for determination of the speciation of antimony in sediment reference samples. Liquid chromatography with a post-column photo-oxidation step and hydride generation atomic fluorescence spectrometry as detection system is applied to the separation and determination of Sb(III), Sb(V) and trimethylantimony species. Post-column decomposition and hydride generation steps were studied for sensitive detection with the AFS detector. This method was applied to investigate the conditions under which speciation analysis of antimony in sediment samples can be carried out. Stability studies of Sb species during the extraction processes of solid matrices, using different reagents solutions, were performed. Results demonstrate that for the extraction yield and the stability of Sb species in different marine sediment extracts, citric acid in ascorbic acid medium was the best extracting solution for antimony speciation analysis in this matrix (between 55% and 65% of total Sb was recovered from CRMs, Sb(III) being the predominant species). The developed method allows the separation of the three compounds within 6 min with detection limits of 30 ng g -1 for Sb(III) and TMSbCl2 and 40 ng g -1 for Sb(V) in sediment samples

  4. Antimony speciation analysis in sediment reference materials using high-performance liquid chromatography coupled to hydride generation atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Potin-Gautier, M. [Laboratoire de Chimie Analytique, BioInorganique et Environnement LCABIE (UMR CNRS 3054), Universite de Pau et des pays de l' Adour, 64000 Pau (France); Pannier, F. [Laboratoire de Chimie Analytique, BioInorganique et Environnement LCABIE (UMR CNRS 3054), Universite de Pau et des pays de l' Adour, 64000 Pau (France)]. E-mail: Florence.pannier@univ-pau.fr; Quiroz, W. [Laboratoire de Chimie Analytique, BioInorganique et Environnement LCABIE (UMR CNRS 3054), Universite de Pau et des pays de l' Adour, 64000 Pau (France); Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Pontificia Universidad catolica de Valparaiso (Chile); Pinochet, H. [Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Pontificia Universidad catolica de Valparaiso (Chile); Gregori, I. de [Laboratorio de Quimica Analitica y Ambiental, Instituto de Quimica, Pontificia Universidad catolica de Valparaiso (Chile)

    2005-11-30

    This work presents the development of suitable methodologies for determination of the speciation of antimony in sediment reference samples. Liquid chromatography with a post-column photo-oxidation step and hydride generation atomic fluorescence spectrometry as detection system is applied to the separation and determination of Sb(III), Sb(V) and trimethylantimony species. Post-column decomposition and hydride generation steps were studied for sensitive detection with the AFS detector. This method was applied to investigate the conditions under which speciation analysis of antimony in sediment samples can be carried out. Stability studies of Sb species during the extraction processes of solid matrices, using different reagents solutions, were performed. Results demonstrate that for the extraction yield and the stability of Sb species in different marine sediment extracts, citric acid in ascorbic acid medium was the best extracting solution for antimony speciation analysis in this matrix (between 55% and 65% of total Sb was recovered from CRMs, Sb(III) being the predominant species). The developed method allows the separation of the three compounds within 6 min with detection limits of 30 ng g{sup -1} for Sb(III) and TMSbCl2 and 40 ng g{sup -1} for Sb(V) in sediment samples.

  5. [Indirect determination of rare earth elements in Chinese herbal medicines by hydride generation-atomic fluorescence spectrometry].

    Science.gov (United States)

    Zeng, Chao; Lu, Jian-Ping; Xue, Min-Hua; Tan, Fang-Wei; Wu, Xiao-Yan

    2014-07-01

    Based on their similarity in chemical properties, rare earth elements were able to form stable coordinated compounds with arsenazo III which were extractable into butanol in the presence of diphenylguanidine. The butanol was removed under reduced pressure distillation; the residue was dissolved with diluted hydrochloric acid. As was released with the assistance of KMnO4 and determined by hydrogen generation-atomic fluorescence spectrometry in terms of rare earth elements. When cesium sulfate worked as standard solution, extraction conditions, KMnO4 amount, distillation temperature, arsenazo III amount, interfering ions, etc were optimized. The accuracy and precision of the method were validated using national standard certified materials, showing a good agreement. Under optimum condition, the linear relationship located in 0.2-25 microg x mL(-1) and detection limit was 0.44 microg x mL(-1). After the herbal samples were digested with nitric acid and hydrogen peroxide, the rare earth elements were determined by this method, showing satisfactory results with relative standard deviation of 1.3%-2.5%, and recoveries of 94.4%-106.0%. The method showed the merits of convenience and rapidness, simple instrumentation and high accuracy. With the rare earths enriched into organic phase, the separation of analytes from matrix was accomplished, which eliminated the interference. With the residue dissolved by diluted hydrochloric acid after the solvent was removed, aqueous sample introduction eliminated the impact of organic phase on the tubing connected to pneumatic pump.

  6. Development of an analytical method for antimony speciation in vegetables by HPLC-hydride generation-atomic fluorescence spectrometry.

    Science.gov (United States)

    Olivares, David; Bravo, Manuel; Feldmann, Jorg; Raab, Andrea; Neaman, Alexander; Quiroz, Waldo

    2012-01-01

    A new method for antimony speciation in terrestrial edible vegetables (spinach, onions, and carrots) was developed using HPLC with hydride generation-atomic fluorescence spectrometry. Mechanical agitation and ultrasound were tested as extraction techniques. Different extraction reagents were evaluated and optimal conditions were determined using experimental design methodology, where EDTA (10 mmol/L, pH 2.5) was selected because this chelate solution produced the highest extraction yield and exhibited the best compatibility with the mobile phase. The results demonstrated that EDTA prevents oxidation of Sb(III) to Sb(V) and maintains the stability of antimony species during the entire analytical process. The LOD and precision (RSD values obtained) for Sb(V), Sb(III), and trimethyl Sb(V) were 0.08, 0.07, and 0.9 microg/L and 5.0, 5.2, and 4.7%, respectively, for a 100 microL sample volume. The application of this method to real samples allowed extraction of 50% of total antimony content from spinach, while antimony extracted from carrots and onion samples ranged between 50 and 60 and 54 and 70%, respectively. Only Sb(V) was detected in three roots (onion and spinach) that represented 60-70% of the total antimony in the extracts.

  7. Cloud point extraction for trace inorganic arsenic speciation analysis in water samples by hydride generation atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shan, E-mail: ls_tuzi@163.com; Wang, Mei, E-mail: wmei02@163.com; Zhong, Yizhou, E-mail: yizhz@21cn.com; Zhang, Zehua, E-mail: kazuki.0101@aliyun.com; Yang, Bingyi, E-mail: e_yby@163.com

    2015-09-01

    A new cloud point extraction technique was established and used for the determination of trace inorganic arsenic species in water samples combined with hydride generation atomic fluorescence spectrometry (HGAFS). As(III) and As(V) were complexed with ammonium pyrrolidinedithiocarbamate and molybdate, respectively. The complexes were quantitatively extracted with the non-ionic surfactant (Triton X-114) by centrifugation. After addition of antifoam, the surfactant-rich phase containing As(III) was diluted with 5% HCl for HGAFS determination. For As(V) determination, 50% HCl was added to the surfactant-rich phase, and the mixture was placed in an ultrasonic bath at 70 °C for 30 min. As(V) was reduced to As(III) with thiourea–ascorbic acid solution, followed by HGAFS. Under the optimum conditions, limits of detection of 0.009 and 0.012 μg/L were obtained for As(III) and As(V), respectively. Concentration factors of 9.3 and 7.9, respectively, were obtained for a 50 mL sample. The precisions were 2.1% for As(III) and 2.3% for As(V). The proposed method was successfully used for the determination of trace As(III) and As(V) in water samples, with satisfactory recoveries. - Highlights: • Cloud point extraction was firstly established to determine trace inorganic arsenic(As) species combining with HGAFS. • Separate As(III) and As(V) determinations improve the accuracy. • Ultrasonic release of complexed As(V) enables complete As(V) reduction to As(III). • Direct HGAFS analysis can be performed.

  8. Simultaneous speciation analysis of Sb(III), Sb(V) and (CH3)3SbCl2 by high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry detection (HPLC-HG-AFS): application to antimony speciation in sea water.

    Science.gov (United States)

    De Gregori, Ida; Quiroz, Waldo; Pinochet, Hugo; Pannier, Florence; Potin-Gautier, Martine

    2005-10-14

    This paper presents an improvement for the simultaneous separation of Sb(V), Sb(III) and (CH3)3SbCl2 species by high performance liquid chromatography (HPLC) and its detection by hydride generation-atomic fluorescence spectrometry (HG-AFS). The separation was performed on an anion exchange column PRP-X100 using a gradient elution program between EDTA/KHP (potasium hydrogen phtalate) as first mobile phase and phosphate solutions solution as the second one. The chromatographic separation and the HG-AFS parameters were optimized by experimental design. The best results were obtained by using an elution program with 20 mmol l(-1) EDTA + 2 mmol(-01) KHP solution at pH 4.5, during 1.15 min, then change to 50 mmol l(-1) (NH4)2HPO4 solution at pH 8.3, switching back after 4.0 min to the first mobile phase, until 5 min, with a constant flow rate of 1.5 ml min(-1). Retention time of Sb(V), Sb(III) and trimethylantimony species were 1.22, 2.31 and 3.45 min and the detection limits were 0.13; 0.07 and 0.13 microg l(-1), respectively. Studies on the stability of this antimony species in sea water samples on the function of the elapsed time of storage in refrigerator at 4 degrees C was performed employing the optimized method. Results revealed that Sb(III) is easily oxidized within some hours to Sb(V) in sea water stored at 4 degrees C. However, when the sea water was immediately mixed with EDTA no oxidation of Sb(III) was observed up to 1 week of storage. The proposed methodology was then applied to the antimony speciation in sea water samples.

  9. Redox speciation analysis of antimony in soil extracts by hydride generation atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Fuentes, Edwar; Pinochet, Hugo; Gregori, Ida de E-mail: idegrego@ucv.cl; Potin-Gautier, Martine

    2003-07-18

    A sensitive atomic spectrometric method for the redox speciation analysis of antimony in soils is described. The method is based on the selective generation of stibine from Sb(III) in a continuous flow system using atomic fluorescence spectrometry for detection. Sb(V) is masked by citric or oxalic acid in HCl medium. The procedure was optimized with synthetic solutions of Sb(III) and Sb(V). The effect of carboxylic acid and HCl concentration on the recovery of Sb(III) and Sb(V) species from standard solutions, and on the fluorescence signal were studied. Both species were extracted from soil with H{sub 2}O, 0.05 mol l{sup -1} EDTA and 0.25 mol l{sup -1} H{sub 2}SO{sub 4}. Since the soil samples were collected from sites impacted by copper mining activities, the effect of Cu{sup 2+} on the determination of antimony in synthetic solutions and soil extracts was studied. Cu{sup 2+} decreased the Sb(III) signal, but had no effect on the total antimony determination. Therefore, the selective determination of Sb(III) was carried out in citric acid-HCl medium, using the analyte addition technique. Total antimony in soil extracts was determined using the standard calibration technique after reducing Sb(V) to Sb(III) at room temperature with KI-ascorbic acid. The Sb(V) concentration was calculated from the difference between total antimony and Sb(III). The limits of detection (PS Analytical, Excalibur Millennium model) were 17 and 10 ng l{sup -1} for Sb(III) and total antimony, respectively, and the R.S.D. at the 0.5-{mu}g l{sup -1} level were 2.5 and 2.4%, respectively. The total antimony concentration of soils is in the mg kg{sup -1} range; the Sb recovery from the different soils by the extracting solutions was between less than 0.02% and approximately 10%. Similar recoveries were obtained using EDTA and sulfuric acid solutions. Sb(V) was found to be the main antimony species extracted from soils.

  10. Continuous flow hydride generation-atomic fluorescence spectrometric determination and speciation of arsenic in wine

    Energy Technology Data Exchange (ETDEWEB)

    Karadjova, Irina B. [Faculty of Chemistry, University of Sofia, 1 James Bourchier Blvd., Sofia 1164 (Bulgaria); Lampugnani, Leonardo [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy)]. E-mail: lampugnani@ipcf.cnr.it; Onor, Massimo [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy); D' Ulivo, Alessandro [C.N.R. Istituto per i processi chimico-fisici, Area della Ricerca di Pisa, Via Moruzzi 1, 56124 Pisa (Italy); Tsalev, Dimiter L. [Faculty of Chemistry, University of Sofia, 1 James Bourchier Blvd., Sofia 1164 (Bulgaria)

    2005-07-15

    Methods for the atomic fluorescence spectrometric (AFS) determination of total arsenic and arsenic species in wines based on continuous flow hydride generation (HG) with atomization in miniature diffusion flame (MDF) are described. For hydride-forming arsenic, L-cysteine is used as reagent for pre-reduction and complexation of arsenite, arsenate, monomethylarsonate and dimethylarsinate. Concentrations of hydrochloric acid and tetrahydroborate are optimized in order to minimize interference by ethanol. Procedure permits determination of the sum of these four species in 5-10-fold diluted samples with limit of detection (LOD) 0.3 and 0.6 {mu}g l{sup -1} As in white and red wines, respectively, with precision between 2% and 8% RSD at As levels within 0.5-10 {mu}g l{sup -1}. Selective arsine generation from different reaction media is used for non-chromatographic determination of arsenic species in wines: citrate buffer at pH 5.1 for As(III); 0.2 mol l{sup -1} acetic acid for arsenite + dimethylarsinate (DMA); 8 mol l{sup -1} HCl for total inorganic arsenic [As(III) + As(V)]; and monomethylarsonate (MMA) calculated by difference. Calibration with aqueous and ethanol-matched standard solutions of As(III) is used for 10- and 5-fold diluted samples, respectively. The LODs are 0.4 {mu}g l{sup -1} for As(III) and 0.3 {mu}g l{sup -1} for the other three As species and precision is within 4-8% RSDs. Arsenic species in wine were also determined by coupling of ion chromatographic separation on an anion exchange column and HG-flame AFS detection. Methods were validated by means of recovery studies and comparative analyses by HG-AFS and electrothermal atomic absorption spectrometry after microwave digestion. The LODs were 0.12, 0.27, 0.15 and 0.13 {mu}g l{sup -1} (as As) and RSDs were 2-6%, 5-9%, 3-7% and 2-5% for As(III), As(V), MMA and DMA arsenic species, respectively. Bottled red and white wines from Bulgaria, Republic of Macedonia and Italy were analyzed by non

  11. Hydride generation atomic fluorescence spectrometric determination of As, Bi, Sb, Se(IV) and Te(IV) in aqua regia extracts from atmospheric particulate matter using multivariate optimization

    Energy Technology Data Exchange (ETDEWEB)

    Moscoso-Perez, Carmen [Department of Analytical Chemistry, Faculty of Sciences, University of A Coruna, Campus da Zapateira s/n, E-15071 A Coruna (Spain); Moreda-Pineiro, Jorge [Department of Analytical Chemistry, Faculty of Sciences, University of A Coruna, Campus da Zapateira s/n, E-15071 A Coruna (Spain)]. E-mail: jmoreda@udc.es; Lopez-Mahia, Purificacion [Department of Analytical Chemistry, Faculty of Sciences, University of A Coruna, Campus da Zapateira s/n, E-15071 A Coruna (Spain); Muniategui-Lorenzo, Soledad [Department of Analytical Chemistry, Faculty of Sciences, University of A Coruna, Campus da Zapateira s/n, E-15071 A Coruna (Spain); Fernandez-Fernandez, Esther [Department of Analytical Chemistry, Faculty of Sciences, University of A Coruna, Campus da Zapateira s/n, E-15071 A Coruna (Spain); Prada-Rodriguez, Dario [Department of Analytical Chemistry, Faculty of Sciences, University of A Coruna, Campus da Zapateira s/n, E-15071 A Coruna (Spain)

    2004-11-22

    A highly sensitive and simple method, based on hydride generation and atomic fluorescence detection, has been developed for the determination of As, Bi, Sb, Se(IV) and Te(IV) in aqua regia extracts from atmospheric particulate matter samples. Atmospheric particulates matter was collected on glass fiber filters using a medium volume sampler (PM1 particulate matter). Two-level factorial designs have been used to optimise the hydride generation atomic fluorescence spectrometry (HG-AFS) procedure. The effects of several parameters affecting the hydride generation efficiency (hydrochloric acid, sodium tetrahydroborate and potassium iodide concentrations and flow rates) have been evaluated using a Plackett-Burman experimental design. In addition, parameters affecting the hydride measurement (delay, analysis and memory times) have been also investigated. The significant parameters obtained (sodium tetrahydroborate concentration, sodium tetrahydroborate flow rate and analysis time for As; hydrochloric acid concentration and sodium tetrahydroborate flow rate for Se(IV); and sodium tetrahydroborate concentration and sodium tetrahydroborate flow rate for Te(IV)) have been optimized by using 2{sup n} + star central composite design. Hydrochloric acid concentration and sodium tetrahydroborate flow rate were the significant parameters obtained for Sb and Bi determination, respectively. Using a univariate approach these parameters were optimized. The accuracy of methods have been verified by using several certified reference materials: SRM 1648 (urban particulate matter) and SRM 1649a (urban dust). Detection limits in the range of 6 x 10{sup -3} to 0.2 ng m{sup -3} have been achieved. The developed methods were applied to several atmospheric particulate matter samples corresponding to A Coruna city (NW Spain)

  12. Hydride generation atomic fluorescence spectrometric determination of As, Bi, Sb, Se(IV) and Te(IV) in aqua regia extracts from atmospheric particulate matter using multivariate optimization

    International Nuclear Information System (INIS)

    Moscoso-Perez, Carmen; Moreda-Pineiro, Jorge; Lopez-Mahia, Purificacion; Muniategui-Lorenzo, Soledad; Fernandez-Fernandez, Esther; Prada-Rodriguez, Dario

    2004-01-01

    A highly sensitive and simple method, based on hydride generation and atomic fluorescence detection, has been developed for the determination of As, Bi, Sb, Se(IV) and Te(IV) in aqua regia extracts from atmospheric particulate matter samples. Atmospheric particulates matter was collected on glass fiber filters using a medium volume sampler (PM1 particulate matter). Two-level factorial designs have been used to optimise the hydride generation atomic fluorescence spectrometry (HG-AFS) procedure. The effects of several parameters affecting the hydride generation efficiency (hydrochloric acid, sodium tetrahydroborate and potassium iodide concentrations and flow rates) have been evaluated using a Plackett-Burman experimental design. In addition, parameters affecting the hydride measurement (delay, analysis and memory times) have been also investigated. The significant parameters obtained (sodium tetrahydroborate concentration, sodium tetrahydroborate flow rate and analysis time for As; hydrochloric acid concentration and sodium tetrahydroborate flow rate for Se(IV); and sodium tetrahydroborate concentration and sodium tetrahydroborate flow rate for Te(IV)) have been optimized by using 2 n + star central composite design. Hydrochloric acid concentration and sodium tetrahydroborate flow rate were the significant parameters obtained for Sb and Bi determination, respectively. Using a univariate approach these parameters were optimized. The accuracy of methods have been verified by using several certified reference materials: SRM 1648 (urban particulate matter) and SRM 1649a (urban dust). Detection limits in the range of 6 x 10 -3 to 0.2 ng m -3 have been achieved. The developed methods were applied to several atmospheric particulate matter samples corresponding to A Coruna city (NW Spain)

  13. Determination of total Sb,Se Te, and Bi and evaluation of their inorganic species in garlic by hydride-generation-atomic-fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Matos Reyes, M.N.; Cervera, M.L.; Guardia, M. de la [University of Valencia, Department of Analytical Chemistry, Burjassot, Valencia (Spain)

    2009-07-15

    A sensitive and simple analytical method has been developed for determination of Sb(III), Sb(V), Se(IV), Se(VI), Te(IV), Te(VI), and Bi(III) in garlic samples by using hydride-generation-atomic-fluorescence spectrometry (HG-AFS). The method is based on a single extraction of the inorganic species by sonication at room temperature with 1 mol L{sup -1} H{sub 2}SO{sub 4} and washing of the solid phase with 0.1% (w/v) EDTA, followed by measurement of the corresponding hydrides generated under two different experimental conditions directly and after a pre-reduction step. The limit of detection of the method was 0.7 ng g{sup -1} for Sb(III), 1.0 ng g{sup -1} for Sb(V), 1.3 ng g{sup -1} for Se(IV), 1.0 ng g{sup -1} for Se(VI), 1.1 ng g{sup -1} for Te(IV), 0.5 ng g{sup -1} for Te(VI), and 0.9 ng g{sup -1} for Bi(III), in all cases expressed in terms of sample dry weight. (orig.)

  14. Arsenic speciation based on ion exchange high-performance liquid chromatography hyphenated with hydride generation atomic fluorescence and on-line UV photo oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Bin He; Jiang Gui-bin; Xu Xiao-bai [Chinese Academy of Scinces, Beijing (China). Research Center for Eco-Environmental Sciences

    2000-12-01

    An on-line method capable of the separation of arsenic species was developed for the speciation of arsenite As(III), arsenate As(V), monomethylarsenic (MMA) and dimethylarsenic acid (DMA) in biological samples. The method is based on the combination of high-performance liquid chromatograph (HPLC) for separation, UV photo oxidation for sample digestion and hydride generation atomic fluorescence spectrometry (HGAFS) for sensitive detection. The best separation results were obtained with an anion-exchange AS11 column protected by an AG11 guard column, and gradient elution with NaH{sub 2}PO{sub 4} and water as mobile phase. The on-line UV photo oxidation with 1.5% K{sub 2}S{sub 2}O{sub 8} in 0.2 mol L{sup -1} NaOH in an 8 m PTFE coil for 40 s ensures the digestion of organoarsenic compounds. Detection limits for the four species were in the range of 0.11-0.15 ng (20 {mu}L injected). Procedures were validated by analysis of the certified reference materials GBW09103 freeze-dried human urine and the results were in good agreement with the certified values of total arsenic concentration. The method has been successfully applied to speciation studies of blood arsenic species with no need of sample pretreatment. Speciation of arsenic in blood samples collected from two patients after the ingestion of realgar-containing drug reveals slight increase of arsenite and DMA, resulting from the digestion of realgar. (orig.)

  15. [Cloud Point extraction for determination of mercury in Chinese herbal medicine by hydride generation atomic fluorescence spectrometry with optimization using Box-Behnken design].

    Science.gov (United States)

    Wang, Mei; Li, Shan; Zhou, Jian-dong; Xu, Ying; Long, Jun-biao; Yang, Bing-yi

    2014-08-01

    Cloud point extraction (CPE) is proposed as a pre-concentration procedure for the determination of Hg in Chinese herbal medicine samples by hydride generation-atomic fluorescence spectrometry (HG-AFS). Hg2+ was reacted with dithizone to form hydrophobic chelate under the condition of pH. Using Triton X-114, as surfactant, chelate was quantitatively extracted into small volume of the surfactant-rich phase by heating the solution in a water bath for 15 min and centrifuging. Four variables including pH, dithizone concentration, Triton X-114 concentration and equilibrium temperature (T) showed the significant effect on extraction efficiency of total Hg evaluated by single-factor experiment, and Box-Behnken design and response surface method- ology were adopted to further investigate the mutual interactions between these variables and to identify their optimal values that would generate maximum extraction efficiency. The results showed that the binomial was used to fit the response to experimental levels of each variable. ALL linear, quadratic terms of four variables, and interactions between pH and Trion X-114, pH and di- thizone affected the response value(extraction efficiency) significantly at 5% level. The optimum extraction conditions were as follows: pH 5.1, Triton X-114 concentration of 1.16 g x L(-1), dithizone concentration of 4.87 mol x L(-1), and T 58.2 degrees C, the predicted value of fluorescence was 4528.74 under the optimum conditions, and the experimental value had only 2.1% difference with it. Under the conditions, fluorescence was linear to mercury concentration in the range of 1-5 microg x L(-1). The limit of detection obtained was 0.01247 microg x L(-1) with the relative standard deviations (R.S.D.) for six replicate determinations of 1.30%. The proposed method was successfully applied to determination of Hg in morindae Radix, Andrographitis and dried tangerine samples with the recoveries of 95.0%-100.0%. Apparently Box-Behnken design combined with

  16. Determination of inorganic arsenic in algae using bromine halogenation and on-line nonpolar solid phase extraction followed by hydride generation atomic fluorescence spectrometry.

    Science.gov (United States)

    Zhang, Weihong; Qi, Yuehan; Qin, Deyuan; Liu, Jixin; Mao, Xuefei; Chen, Guoying; Wei, Chao; Qian, Yongzhong

    2017-08-01

    Accurate, stable and fast analysis of toxic inorganic arsenic (iAs) in complicated and arsenosugar-rich algae matrix is always a challenge. Herein, a novel analytical method for iAs in algae was reported, using bromine halogenation and on-line nonpolar solid phase extraction (SPE) followed by hydride generation atomic fluorescence spectrometry (HG-AFS). The separation of iAs from algae was first performed by nonpolar SPE sorbent using Br - for arsenic halogenation. Algae samples were extracted with 1% perchloric acid. Then, 1.5mL extract was reduced by 1% thiourea, and simultaneously reacted (for 30min) with 50μL of 10% KBr for converting iAs to AsBr 3 after adding 3.5mL of 70% HCl to 5mL. A polystyrene (PS) resin cartridge was employed to retain arsenicals, which were hydrolyzed, eluted from the PS resin with H 2 O, and categorized as iAs. The total iAs was quantified by HG-AFS. Under optimum conditions, the spiked recoveries of iAs in real algae samples were in the 82-96% range, and the method achieved a desirable limit of detection of 3μgkg -1 . The inter-day relative standard deviations were 4.5% and 4.1% for spiked 100 and 500μgkg -1 respectively, which proved acceptable for this method. For real algae samples analysis, the highest presence of iAs was found in sargassum fusiforme, followed by kelp, seaweed and laver. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Ionic liquid-assisted separation and determination of selenium species in food and beverage samples by liquid chromatography coupled to hydride generation atomic fluorescence spectrometry.

    Science.gov (United States)

    Castro Grijalba, Alexander; Fiorentini, Emiliano F; Wuilloud, Rodolfo G

    2017-03-31

    Different ionic liquids (ILs) were assayed as mobile phase modifiers for the separation and determination of selenite [Se(IV)], selenate [Se(VI)], selenomethionine (SeMet) and Se-methylselenocysteine (SeMeSeCys) by reversed-phase high-performance liquid chromatography coupled to hydride generation atomic fluorescence spectrometry (RP-HPLC-HG-AFS). The use of several ILs: 1-butyl-3-methylimidazolium chloride, 1-hexyl-3-methylimidazolium chloride ([C 6 mim]Cl), 1-octyl-3-methylimidazolium chloride, 1-dodecyl-3-methylimidazolium bromide, 1-hexadecyl-3-methylimidazolium bromide and tributyl(methyl)phosphonium methylsulphate was evaluated. Also, the effect of pH, buffer type and IL concentration on the separation of Se species was studied. Complete separation was attained within 12min using a C 8 column and a gradient performed with a mobile phase containing 0.1% (v/v) [C 6 mim]Cl at pH 6.0. The proposed method allows the separation of inorganic and organic Se species in a single chromatographic run, adding further benefits over already reported methods based on RP-HPLC. In addition, the influence of ILs on the AFS signals of each Se species was evaluated and a multivariate methodology was used for optimization of AFS sensitivity. The limits of detection were 0.92, 0.86, 1.41 and 1.19μgL -1 for Se(IV), Se(VI), SeMet and SeMeSeCys, respectively. The method was successfully applied for speciation analysis of Se in complex samples, such as wine, beer, yeast and garlic. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Arsenic fractionation in agricultural soil using an automated three-step sequential extraction method coupled to hydride generation-atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Rosas-Castor, J.M. [Universidad Autónoma de Nuevo León, UANL, Facultad de Ciencias Químicas, Cd. Universitaria, San Nicolás de los Garza, Nuevo León, C.P. 66451 Nuevo León (Mexico); Group of Analytical Chemistry, Automation and Environment, University of Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca (Spain); Portugal, L.; Ferrer, L. [Group of Analytical Chemistry, Automation and Environment, University of Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca (Spain); Guzmán-Mar, J.L.; Hernández-Ramírez, A. [Universidad Autónoma de Nuevo León, UANL, Facultad de Ciencias Químicas, Cd. Universitaria, San Nicolás de los Garza, Nuevo León, C.P. 66451 Nuevo León (Mexico); Cerdà, V. [Group of Analytical Chemistry, Automation and Environment, University of Balearic Islands, Cra. Valldemossa km 7.5, 07122 Palma de Mallorca (Spain); Hinojosa-Reyes, L., E-mail: laura.hinojosary@uanl.edu.mx [Universidad Autónoma de Nuevo León, UANL, Facultad de Ciencias Químicas, Cd. Universitaria, San Nicolás de los Garza, Nuevo León, C.P. 66451 Nuevo León (Mexico)

    2015-05-18

    Highlights: • A fully automated flow-based modified-BCR extraction method was developed to evaluate the extractable As of soil. • The MSFIA–HG-AFS system included an UV photo-oxidation step for organic species degradation. • The accuracy and precision of the proposed method were found satisfactory. • The time analysis can be reduced up to eight times by using the proposed flow-based BCR method. • The labile As (F1 + F2) was <50% of total As in soil samples from As-contaminated-mining zones. - Abstract: A fully automated modified three-step BCR flow-through sequential extraction method was developed for the fractionation of the arsenic (As) content from agricultural soil based on a multi-syringe flow injection analysis (MSFIA) system coupled to hydride generation-atomic fluorescence spectrometry (HG-AFS). Critical parameters that affect the performance of the automated system were optimized by exploiting a multivariate approach using a Doehlert design. The validation of the flow-based modified-BCR method was carried out by comparison with the conventional BCR method. Thus, the total As content was determined in the following three fractions: fraction 1 (F1), the acid-soluble or interchangeable fraction; fraction 2 (F2), the reducible fraction; and fraction 3 (F3), the oxidizable fraction. The limits of detection (LOD) were 4.0, 3.4, and 23.6 μg L{sup −1} for F1, F2, and F3, respectively. A wide working concentration range was obtained for the analysis of each fraction, i.e., 0.013–0.800, 0.011–0.900 and 0.079–1.400 mg L{sup −1} for F1, F2, and F3, respectively. The precision of the automated MSFIA–HG-AFS system, expressed as the relative standard deviation (RSD), was evaluated for a 200 μg L{sup −1} As standard solution, and RSD values between 5 and 8% were achieved for the three BCR fractions. The new modified three-step BCR flow-based sequential extraction method was satisfactorily applied for arsenic fractionation in real agricultural

  19. Speciation of the immediately mobilisable As(III), As(V), MMA and DMA in river sediments by high performance liquid chromatography-hydride generation-atomic fluorescence spectrometry following ultrasonic extraction

    International Nuclear Information System (INIS)

    Huerga, A.; Lavilla, I.; Bendicho, C.

    2005-01-01

    In this work, a fast method is developed for the speciation of As(III), As(V), MMA and DMA in the immediately mobilisable fraction of river sediments (i.e. water-soluble and phosphate-exchangeable) by high performance liquid chromatography-hydride generation-atomic fluorescence detection (HPLC-HG-AFD) after extraction using focused ultrasound. The influence of relevant parameters influencing an ion-pairing chromatographic separation following isocratic elution (i.e. amount of MeOH in the mobile phase, ion pair reagent concentration, pH, flow rate) was studied. Focused ultrasound transmitted from an ultrasonic probe provided the same extractable contents as conventional extraction with no changes in the species distribution. The effect of the drying step over extraction of As species was investigated. The following drying procedures were compared: freeze-, oven-, microwave- and air-drying. No influence of the drying operation on the water-extractable fraction was observed. However, freeze- and air-drying yielded significantly higher phosphate-extractable amounts of As(III) and As(V) as compared to oven and microwaves. Detection limits for the As species were in the range 1.3-4.1 ng/g for the water-soluble fraction and 1.6-4.8 ng/g for the phosphate buffer exchangeable fraction. The method was applied to the speciation of immediately mobilisable As(III), As(V), DMA and MMA in 11 sediment samples collected along the beds of the Louro River (southern Galicia, Spain)

  20. Use of aqueous slurries of coal fly ash samples for the direct determination of As, Sb, and Se by hydride generation-atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Moreda-Pineiro, J.; Moscoso-Perez, C.; Lopez-Mahia, P.; Muniategui-Lorenzoa, S.; Fernandez-Fernandez, E.; Prada-Rodriguez, D. [University of La Coruna, La Coruna (Spain). Faculty of Science

    2006-01-15

    A highly sensitive and simple method was developed based on the continuous hydride generation of aqueous coal fly ash slurry samples and the direct atomic fluorescence detection of As, Sb, and Se. A 2{sup 8} x 3/64 Plackett-Burman design was used as the multivariate strategy for evaluation of the effects of several variables involved in hydride generation efficiency (HCl, NaBH{sub 4}, NaBH{sub 4} flow rate, particle size, and slurry concentration). In addition, measurement time was also considered. Slurry concentration was the significant variable for As, hydrochloric acid concentration for Sb determination; no significant variable was found for Se. Optimum values for the significant variables were selected by using univariate approaches. The precision obtained ({lt} 8.0 %) was adequate for the determination of several hydride-forming elements in coal fly ash samples. Since there was a matrix effect, the standard addition method was required. Accuracy was assessed by analyzing NIST 1633b Coal Fly Ash certified reference material. Detection limits within the range of 0.03-0.67 {mu} g g{sup -1} were achieved. The developed methods were applied to several coal fly ash samples obtained from a coal-fired power plant.

  1. Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline

    Directory of Open Access Journals (Sweden)

    Blanca G. Beltrán

    2016-01-01

    Full Text Available Hydride generation (HG of lead technique presents interferences from foreign ions of complex matrix samples. In order to minimize these interferences, the effect of masking agents such as KI, L-cysteine, and 1,10-phenanthroline was studied in the absence and in the presence of selected interfering species (As, Cr, Cu, and Fe. Different modes of addition of masking agents were accomplished, that is, to either sample or KBH4 reducing solution. The lead determinations were performed using a flow injection analysis (FIA system coupled to HG and atomic fluorescence spectrometry (AFS. The linearity of calibration curves (1–10 μg Pb L−1 was not affected by the addition of the masking agents. The use of KI in the reducing solution diminished interferences from concentrations of As and Cu, while 1,10-phenanthroline showed a positive effect on the interference by As. Moreover, Cr and Cu appeared to be the most serious interfering ions for plumbane (PbH4, because they drastically reduced the analytical signal of lead. Fe did not present any interference under the employed experimental conditions, even at high levels. The accuracy was established through the analysis of certified reference material (i.e., BCR-610, groundwater using KI as masking agent. The detection limit reached by FIA-HG-AFS proposed methodology was 0.03 μg Pb L−1.

  2. Simultaneous determination of total arsenic and total selenium in Chinese medicinal herbs by hydride generation atomic fluorescence spectrometry in tartaric acid medium

    International Nuclear Information System (INIS)

    Liu Zhanfeng; Sun Hanwen; Shen Shigang; Li Liqing; Shi Hongmei

    2005-01-01

    By HG-AFS, a new method was proposed for simultaneous determination of total arsenic and total selenium existed in the Chinese medicinal herbs in tartaric acid medium. The effects of analytical conditions and coexisting ions on the fluorescence signal intensity of analytes were investigated. The proposed method was provided with linear response ranges above 22 μg l -1 for As and 44 μg l -1 for Se, and the detection limits of 0.13 and 0.12 μg l -1 were obtained for As and Se respectively. The recoveries of 93.8-96.1% for As and 95.3-99.1% for Se, and the precision of 1.2-3.8% and 2.4-5.3% (R.S.D., n = 8) respectively, were obtained via simultaneous determined four samples of Chinese medicinal herbs and three certified botanic reference materials successfully. The proposed method has the advantages of simple operation, high sensitivity and high efficiency

  3. Fluorescence detection: SPIE volume 743

    International Nuclear Information System (INIS)

    Menzel, E.R.

    1987-01-01

    This book contains proceedings arranged into four sessions. They are: Fluorescence spectroscopic techniques; Fluorescence in analysis and materials characterization; Fluorescence in medicine and biochemistry; and Fluorescence in criminalistics

  4. Fluorescence detection: SPIE volume 743

    Energy Technology Data Exchange (ETDEWEB)

    Menzel, E.R.

    1987-01-01

    This book contains proceedings arranged into four sessions. They are: Fluorescence spectroscopic techniques; Fluorescence in analysis and materials characterization; Fluorescence in medicine and biochemistry; and Fluorescence in criminalistics.

  5. Fractionation and redox speciation of antimony in agricultural soils by hydride generation--atomic fluorescence spectrometry and stability of Sb(III) and Sb(V) during extraction with different extractant solutions.

    Science.gov (United States)

    Fuentes, Edwar; Pinochet, Hugo; Potin-Gautier, Martine; De Graegori, Ida

    2004-01-01

    This stability of Sb(III) and Sb(V) species was studied during single extraction from soils by water. EDTA, diluted H2SO4 and H3PO4, and oxalic acid/oxalate solutions, with and without ascorbic acid, were used as stabilizing reagent of both Sb species. Antimony redox speciation in soil extracts was performed by selective hydride generation-atomic fluorescence spectrometry. Simulated extraction procedures (without soil) showed that, except in oxalate medium, Sb(III) was oxidized to Sb(V), and this reaction was avoided with ascorbic acid. Recovery studies from a spiked agricultural soil showed that no oxidation but sorption of Sb(III) occurred during the extraction process in water and H2SO4 medium, and quantitative oxidation in EDTA and oxalate medium. With ascorbic acid, this oxidation was totally avoided in EDTA and partially avoided in oxalate solution. A new sequential extraction procedure was proposed and applied to the fractionation and redox speciation of antimony in agricultural soils, using EDTA + ascorbic acid, pH 7 (available under complexing and moderately reducible conditions); oxalic acid/oxalate + ascorbic acid (extractable in reducible conditions) and HNO3 + HCl + HF (residual fraction). The proposed extraction scheme can provide information about the availability and mobility of antimony redox species in agricultural soils.

  6. Fluorescence detection of dental calculus

    International Nuclear Information System (INIS)

    Gonchukov, S; Sukhinina, A; Vdovin, Yu; Biryukova, T

    2010-01-01

    This work is devoted to the optimization of fluorescence dental calculus diagnostics in optical spectrum. The optimal wavelengths for fluorescence excitation and registration are determined. Two spectral ranges 620 – 645 nm and 340 – 370 nm are the most convenient for supra- and subgingival calculus determination. The simple implementation of differential method free from the necessity of spectrometer using was investigated. Calculus detection reliability in the case of simple implementation is higher than in the case of spectra analysis at optimal wavelengths. The use of modulated excitation light and narrowband detection of informative signal allows us to decrease essentially its diagnostic intensity even in comparison with intensity of the low level laser dental therapy

  7. Detection of Counterfeit Tequila by Fluorescence Spectroscopy

    Directory of Open Access Journals (Sweden)

    José Manuel de la Rosa Vázquez

    2015-01-01

    Full Text Available An ultraviolet (UV light induced fluorescence study to discriminate fake tequila from genuine ones is presented. A portable homemade system based on four light emitting diodes (LEDs from 255 to 405 nm and a miniature spectrometer was used. It has been shown that unlike fake and silver tequila, which produce weak fluorescence signal, genuine mixed, rested, and aged tequilas show high fluorescence emission in the range from 400 to 750 nm. The fluorescence intensity grows with aging in 100% agave tequila. Such fluorescence differences can even be observed with naked eyes. The presented results demonstrate that the fluorescence measurement could be a good method to detect counterfeit tequila.

  8. Fluorescence quenching based alkaline phosphatase activity detection.

    Science.gov (United States)

    Mei, Yaqi; Hu, Qiong; Zhou, Baojing; Zhang, Yonghui; He, Minhui; Xu, Ting; Li, Feng; Kong, Jinming

    2018-01-01

    Simple and fast detection of alkaline phosphatase (ALP) activity is of great importance for diagnostic and analytical applications. In this work, we report a turn-off approach for the real-time detection of ALP activity on the basis of the charge transfer induced fluorescence quenching of the Cu(BCDS) 2 2- (BCDS = bathocuproine disulfonate) probe. Initially, ALP can enzymatically hydrolyze the substrate ascorbic acid 2-phosphate to release ascorbic acid (AA). Subsequently, the AA-mediated reduction of the Cu(BCDS) 2 2- probe, which displays an intense photoluminescence band at the wavelength of 402nm, leads to the static quenching of fluorescence of the probe as a result of charge transfer. The underlying mechanism of the fluorescence quenching was demonstrated by quantum mechanical calculations. The Cu(BCDS) 2 2- probe features a large Stokes shift (86nm) and is highly immune to photo bleaching. In addition, this approach is free of elaborately designed fluorescent probes and allows the detection of ALP activity in a real-time manner. Under optimal conditions, it provides a fast and sensitive detection of ALP activity within the dynamic range of 0-220mUmL -1 , with a detection limit down to 0.27mUmL -1 . Results demonstrate that it is highly selective, and applicable to the screening of ALP inhibitors in drug discovery. More importantly, it shows a good analytical performance for the direct detection of the endogenous ALP levels of undiluted human serum and even whole blood samples. Therefore, the proposed charge transfer based approach has great potential in diagnostic and analytical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. 21 CFR 872.1745 - Laser fluorescence caries detection device.

    Science.gov (United States)

    2010-04-01

    ... is to aid in the detection of tooth decay by measuring increased laser induced fluorescence. (b... aids in the detection of tooth decay by measuring increased laser induced fluorescence; and (3) The... SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Diagnostic Devices § 872.1745 Laser fluorescence caries...

  10. Performance evaluation of spot detection algorithms in fluorescence microscopy images

    CSIR Research Space (South Africa)

    Mabaso, M

    2012-10-01

    Full Text Available Detection of messenger Ribonucleic Acid (mRNA) spots in fluorescence microscopy images is of great importance for biologists seeking better understanding of cell functionality. Fluorescence microscopy and specific staining methods make biological...

  11. Using Fluorescent Viruses for Detecting Bacteria in Water

    Science.gov (United States)

    Tabacco, Mary Beth; Qian, Xiaohua; Russo, Jaimie A.

    2009-01-01

    A method of detecting water-borne pathogenic bacteria is based partly on established molecular-recognition and fluorescent-labeling concepts, according to which bacteria of a species of interest are labeled with fluorescent reporter molecules and the bacteria can then be detected by fluorescence spectroscopy. The novelty of the present method lies in the use of bacteriophages (viruses that infect bacteria) to deliver the fluorescent reporter molecules to the bacteria of the species of interest.

  12. Optimal fluorescence waveband determination for detecting defect cherry tomatoes using fluorescence excitation-emission matrix

    Science.gov (United States)

    A multi-spectral fluorescence imaging technique was used to detect defect cherry tomatoes. The fluorescence excitation and emission matrix was used to measure for defects, sound surface, and stem areas to determine the optimal fluorescence excitation and emission wavelengths for discrimination. Two-...

  13. Sensitive detection of fluorescence in western blotting by merging images.

    Science.gov (United States)

    Kondo, Yukari; Higa, Shinichiro; Iwasaki, Takeshi; Matsumoto, Tomoya; Maehara, Kazumitsu; Harada, Akihito; Baba, Yoshihiro; Fujita, Masatoshi; Ohkawa, Yasuyuki

    2018-01-01

    The western blotting technique is widely used to analyze protein expression levels and protein molecular weight. The chemiluminescence method is mainly used for detection due to its high sensitivity and ease of manipulation, but it is unsuitable for detailed analyses because it cannot be used to detect multiple proteins simultaneously. Recently, more attention has been paid to the fluorescence detection method because it is more quantitative and is suitable for the detection of multiple proteins simultaneously. However, fluorescence detection can be limited by poor image resolution and low detection sensitivity. Here, we describe a method to detect fluorescence in western blots using fluorescence microscopy to obtain high-resolution images. In this method, filters and fluorescent dyes are optimized to enhance detection sensitivity to a level similar to that of the chemiluminescence method.

  14. Optimal Fluorescence Waveband Determination for Detecting Defective Cherry Tomatoes Using a Fluorescence Excitation-Emission Matrix

    Directory of Open Access Journals (Sweden)

    In-Suck Baek

    2014-11-01

    Full Text Available A multi-spectral fluorescence imaging technique was used to detect defective cherry tomatoes. The fluorescence excitation and emission matrix was used to measure for defects, sound surface and stem areas to determine the optimal fluorescence excitation and emission wavelengths for discrimination. Two-way ANOVA revealed the optimal excitation wavelength for detecting defect areas was 410 nm. Principal component analysis (PCA was applied to the fluorescence emission spectra of all regions at 410 nm excitation to determine the emission wavelengths for defect detection. The major emission wavelengths were 688 nm and 506 nm for the detection. Fluorescence images combined with the determined emission wavebands demonstrated the feasibility of detecting defective cherry tomatoes with >98% accuracy. Multi-spectral fluorescence imaging has potential utility in non-destructive quality sorting of cherry tomatoes.

  15. A fluorescent polymer dots positive readout fluorescent quenching lateral flow sensor for ractopamine rapid detection.

    Science.gov (United States)

    Shi, Cong Ying; Deng, Ning; Liang, Jia Jie; Zhou, Ke Nan; Fu, Qiang Qiang; Tang, Yong

    2015-01-07

    A fluorescent polymer dots positive readout and sensitive lateral flow assay (LFA) based on fluorescent quenching has been developed to detect ractopamine (Rac), a chemical residue in food, harmful to human health. Compared with traditional LFA strips, these fluorescent quenching LFA (FQLFA) strips provide a positive correlation method that allows users to obtain results from a weak fluorescent signal. The immunoassay strip scheme is based on the fact that fluorescent polymer dots (FPDs) in close proximity to gold nanoparticles (AuNPs) represent a strong fluorescent quenching. We show that the FQLFA strips can be used as a source to quantitatively analyze Rac in phosphate buffers (PB), swine urine and muscle tissue samples. The lowest detection limitation of the FQLFA was 0.16 ng mL(-1). Our results indicated that this novel scheme was more suitable for rapid detection of small molecules. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Sensitive turn-on fluorescent detection of tartrazine based on fluorescence resonance energy transfer.

    Science.gov (United States)

    Huang, Sheng Tian; Shi, Yan; Li, Nian Bing; Luo, Hong Qun

    2012-01-18

    We introduce a sensitive, rapid, label-free and general fluorescent method for the determination of tartrazine by competitive binding to reduced graphene oxide (rGO) against fluorescein, and the fluorescence recovery upon fluorescein desorption from rGO provides a quantitative readout for tartrazine, giving a detection limit of 0.53 ng mL(-1).

  17. Tomato seeds maturity detection system based on chlorophyll fluorescence

    Science.gov (United States)

    Li, Cuiling; Wang, Xiu; Meng, Zhijun

    2016-10-01

    Chlorophyll fluorescence intensity can be used as seed maturity and quality evaluation indicator. Chlorophyll fluorescence intensity of seed coats is tested to judge the level of chlorophyll content in seeds, and further to judge the maturity and quality of seeds. This research developed a detection system of tomato seeds maturity based on chlorophyll fluorescence spectrum technology, the system included an excitation light source unit, a fluorescent signal acquisition unit and a data processing unit. The excitation light source unit consisted of two high power LEDs, two radiators and two constant current power supplies, and it was designed to excite chlorophyll fluorescence of tomato seeds. The fluorescent signal acquisition unit was made up of a fluorescence spectrometer, an optical fiber, an optical fiber scaffolds and a narrowband filter. The data processing unit mainly included a computer. Tomato fruits of green ripe stage, discoloration stage, firm ripe stage and full ripe stage were harvested, and their seeds were collected directly. In this research, the developed tomato seeds maturity testing system was used to collect fluorescence spectrums of tomato seeds of different maturities. Principal component analysis (PCA) method was utilized to reduce the dimension of spectral data and extract principal components, and PCA was combined with linear discriminant analysis (LDA) to establish discriminant model of tomato seeds maturity, the discriminant accuracy was greater than 90%. Research results show that using chlorophyll fluorescence spectrum technology is feasible for seeds maturity detection, and the developed tomato seeds maturity testing system has high detection accuracy.

  18. Detection of rheumatoid arthritis in humans by fluorescence imaging

    Science.gov (United States)

    Ebert, Bernd; Dziekan, Thomas; Weissbach, Carmen; Mahler, Marianne; Schirner, Michael; Berliner, Birgitt; Bauer, Daniel; Voigt, Jan; Berliner, Michael; Bahner, Malte L.; Macdonald, Rainer

    2010-02-01

    The blood pool agent indo-cyanine green (ICG) has been investigated in a prospective clinical study for detection of rheumatoid arthritis using fluorescence imaging. Temporal behavior as well as spatial distribution of fluorescence intensity are suited to differentiate healthy and inflamed finger joints after i.v. injection of an ICG bolus.

  19. Design of Fluorescent Compounds for Scintillation Detection

    Energy Technology Data Exchange (ETDEWEB)

    Pla-Dalmau, Anna [Northern Illinois U.

    1990-01-01

    Plastic scintillation detectors for high energy physics applications require the development of new fluorescent compounds to meet the demands set by the future generation of particle accelerators such as the Superconducting Supercollider (SSe). Plastic scintillators are commonly based on a polymer matrix doped with two fluorescent compounds: the primary dopant and the wavelength shifter. Their main characteristics are fast response time and high quantum efficiency. The exposure to larger radiation doses and demands for larger light output questions their survivability in the future experiments. A new type of plastic scintillator - intrinsic scintillator - has been suggested. It uses a single dopant as primary and wavelength shifter, and should be less susceptible to radiation damage....

  20. A simple and sensitive fluorescent probe for specific detection of ...

    Indian Academy of Sciences (India)

    Afluorescent probe, with simplicity of structure and convenience of synthesis, is capable of detecting cysteine over other biothiols, such as homocysteine and glutathione. The detection limit of 60nM and 190-fold increase in fluorescence intensity offer advantage for detection of Cys in biological systems. Furthermore, the ...

  1. Phenylethynylpyrene excimer forming hybridization probes for fluorescence SNP detection

    DEFF Research Database (Denmark)

    Prokhorenko, Igor A.; Astakhova, Irina V.; Momynaliev, Kuvat T.

    2009-01-01

    Excimer formation is a unique feature of some fluorescent dyes (e.g., pyrene) which can be used for probing the proximity of biomolecules. Pyrene excimer fluorescence has previously been used for homogeneous detection of single nucleotide polymorphism (SNP) on DNA. 1-Phenylethynylpyrene (1-1-PEPy......), a photostable pyrene derivative with redshifted fluorescence, is able to form excimers (emission maximum about 500-510 nm) and is well suitable for nucleic acid labeling. We have shown the utility of 1-1-PEPy in the excimer-forming DNA probes for detection of 2144A/G and 2143A/G transitions, and 2143A...

  2. Study of the fluorescence signal for gastrointestinal dysplasia detection

    Science.gov (United States)

    Pimenta, S.; Castanheira, E. M. S.; Minas, G.

    2014-08-01

    The detection of cancer at the dysplasia stage is one of the most important goals in biomedical research. Optical techniques, specifically diffuse reflectance and intrinsic fluorescence, may improve the ability to detect gastrointestinal (GI) cancers, since they have exquisite sensitivity to some intrinsic biomarkers present on the tissues. This work follows the research that has been done towards the implementation of a spectroscopy microsystem for the early detection of GI cancers. For that purpose, the behavior of the fluorescence signal, at different temperatures and considering the most important biomarkers in GI malignancy detection, was studied and presented.

  3. Monolithic PDMS passband filters for fluorescence detection.

    Science.gov (United States)

    Llobera, Andreu; Demming, Stefanie; Joensson, Haakan N; Vila-Planas, J; Andersson-Svahn, Helene; Büttgenbach, Stephanus

    2010-08-07

    We present the fabrication and characteristics of monolithically integrated ink dyed poly(dimethylsiloxane) (PDMS) filters for optical sensing in disposable lab-on-a-chip. This represents a migration of auxillary functions onto the disposable chip with the goal of producing truly portable systems. Filters made from commercially available ink (Pelikan) directly mixed into PDMS oligomer without the use of any additional solvents were patterned with standard soft lithography technologies. Furthermore, a fabrication process based on capillary forces is presented allowing PDMS coloration of arbitrary shapes. Different filters of varying thickness fabricated using red, green and blue ink in four different concentrations were characterized. The optimal performance was found with filter thicknesses of 250 microm and ink to PDMS ratios of 0.1 (mL ink : mL PDMS oligomer) resulting in a transmittance ranging from -15.1 dB to -12.3 dB in the stopband and from -4.0 dB to -2.5 dB in the passband. Additionally, we demonstrate the robustness of this approach as the ink dyed PDMS filters do not exhibit temporal ageing due to diffusion or autofluorescence. We also show that such filters can easily be integrated in fluorescence systems, with stopbands efficient enough to allow fluorescence measurements under non-optimal conditions (broadband excitation, 180 degrees configuration). Integrated ink dyed PDMS filters add robust optical functionalities to disposable microdevices at a low cost and will enable the use of these devices for a wide range of fluorescence and absorbance based biological and chemical analysis.

  4. Fluorescence detection of organic molecules in the Jovian atmosphere.

    Science.gov (United States)

    Levine, J S; Rogowski, R S

    1975-07-01

    A search for fluorescent emission due to the presence of possible organic molecules in the Jovian atmosphere is described. We first consider natural Jovian fluorescent emission excited by precipitating auroral particles. Due to our lack of knowledge of the Jovian precipitation particle energies and fluxes we next consider fluorescent emission excited by a laser system aboard a Jupiter spacecraft. Laser-induced fluorescence is routinely used to monitor trace constituents and pollutants in the terrestrial atmosphere. Several spacecraft laser systems are currently under development. Our calculations indicate that laser-induced fluorescent detection is approximately two orders of magnitude more sensitive than rocket ultraviolet measurements of possible Jovian absorption features at 2600 A that have been attributed to the presence of adenine or benzene.

  5. Smart phone based bacterial detection using bio functionalized fluorescent nanoparticles

    International Nuclear Information System (INIS)

    Rajendran, Vinoth Kumar; Bakthavathsalam, Padmavathy; Ali, Baquir Mohammed Jaffar

    2014-01-01

    We are describing immunochromatographic test strips with smart phone-based fluorescence readout. They are intended for use in the detection of the foodborne bacterial pathogens Salmonella spp. and Escherichia coli O157. Silica nanoparticles (SiNPs) were doped with FITC and Ru(bpy), conjugated to the respective antibodies, and then used in a conventional lateral flow immunoassay (LFIA). Fluorescence was recorded by inserting the nitrocellulose strip into a smart phone-based fluorimeter consisting of a light weight (40 g) optical module containing an LED light source, a fluorescence filter set and a lens attached to the integrated camera of the cell phone in order to acquire high-resolution fluorescence images. The images were analysed by exploiting the quick image processing application of the cell phone and enable the detection of pathogens within few minutes. This LFIA is capable of detecting pathogens in concentrations as low as 10 5 cfu mL −1 directly from test samples without pre-enrichment. The detection is one order of magnitude better compared to gold nanoparticle-based LFIAs under similar condition. The successful combination of fluorescent nanoparticle-based pathogen detection by LFIAs with a smart phone-based detection platform has resulted in a portable device with improved diagnosis features and having potential application in diagnostics and environmental monitoring. (author)

  6. Characteristics of subgingival calculus detection by multiphoton fluorescence microscopy

    Science.gov (United States)

    Tung, Oi-Hong; Lee, Shyh-Yuan; Lai, Yu-Lin; Chen, How-Foo

    2011-06-01

    Subgingival calculus has been recognized as a major cause of periodontitis, which is one of the main chronic infectious diseases of oral cavities and a principal cause of tooth loss in humans. Bacteria deposited in subgingival calculus or plaque cause gingival inflammation, function deterioration, and then periodontitis. However, subgingival calculus within the periodontal pocket is a complicated and potentially delicate structure to be detected with current dental armamentaria, namely dental x-rays and dental probes. Consequently, complete removal of subgingival calculus remains a challenge to periodontal therapies. In this study, the detection of subgingival calculus employing a multiphoton autofluorescence imaging method was characterized in comparison with a one-photon confocal fluorescence imaging technique. Feasibility of such a system was studied based on fluorescence response of gingiva, healthy teeth, and calculus with and without gingiva covered. The multiphoton fluorescence technology perceived the tissue-covered subgingival calculus that cannot be observed by the one-photon confocal fluorescence method.

  7. Cyclodextrin-carbon nanotube composites for fluorescent detection of cholesterol

    Science.gov (United States)

    Gilbert, Simeon; Jeong, Hae Kyung; Dowben, P. A.

    2017-11-01

    The efficiency of cyclodextrin-carbon nanotube composites (CD-CNT) for cholesterol detection was investigated using their fluorescent yields in the presence of rhodamine 6G (R6G). The CD-CNT composites using α-, β- and γ-cyclodextrin (x-CD) all showed strong fluorescent responses to cholesterol when in the presence of R6G. The α-CD based composites, however, exhibit more dramatic fluorescent changes in response to cholesterol, over a wider range of cholesterol concentrations, and also display the highest binding constant of 2.98 × 105 M-1 with cholesterol. The effectiveness of these fluorescent responses for the detection of cholesterol depends primarily on the concentration and cavity size of the CD.

  8. Satellite-detected fluorescence reveals global physiology of ocean phytoplankton

    Directory of Open Access Journals (Sweden)

    M. J. Behrenfeld

    2009-05-01

    Full Text Available Phytoplankton photosynthesis links global ocean biology and climate-driven fluctuations in the physical environment. These interactions are largely expressed through changes in phytoplankton physiology, but physiological status has proven extremely challenging to characterize globally. Phytoplankton fluorescence does provide a rich source of physiological information long exploited in laboratory and field studies, and is now observed from space. Here we evaluate the physiological underpinnings of global variations in satellite-based phytoplankton chlorophyll fluorescence. The three dominant factors influencing fluorescence distributions are chlorophyll concentration, pigment packaging effects on light absorption, and light-dependent energy-quenching processes. After accounting for these three factors, resultant global distributions of quenching-corrected fluorescence quantum yields reveal a striking consistency with anticipated patterns of iron availability. High fluorescence quantum yields are typically found in low iron waters, while low quantum yields dominate regions where other environmental factors are most limiting to phytoplankton growth. Specific properties of photosynthetic membranes are discussed that provide a mechanistic view linking iron stress to satellite-detected fluorescence. Our results present satellite-based fluorescence as a valuable tool for evaluating nutrient stress predictions in ocean ecosystem models and give the first synoptic observational evidence that iron plays an important role in seasonal phytoplankton dynamics of the Indian Ocean. Satellite fluorescence may also provide a path for monitoring climate-phytoplankton physiology interactions and improving descriptions of phytoplankton light use efficiencies in ocean productivity models.

  9. Detection of Salmonella typhi utilizing bioconjugated fluorescent polymeric nanoparticles

    International Nuclear Information System (INIS)

    Jain, Swati; Chattopadhyay, Sruti; Jackeray, Richa; Abid, Zainul; Singh, Harpal

    2016-01-01

    Present work demonstrates effective utilization of functionalized polymeric fluorescent nanoparticles as biosensing probe for the detection of Salmonella typhi bacteria on modified polycarbonate (PC) filters in about 3 h. Antibody modified-PC membranes were incubated with contaminated bacterial water for selective capturing which were detected by synthesized novel bioconjugate probe. Core–shell architecture of polymeric nanoparticles endows them with aqueous stabilization and keto-enolic functionalities making them usable for covalently linking S. typhi antibodies without any crosslinker or activator. Bradford analysis revealed that one nanoparticle has an average of 3.51 × 10 −19  g or 21 × 10 4 bound S. typhi Ab molecules. Analysis of the regions of interest (ROI) in fluorescent micrographs of modified fluoroimmunoassay showed higher detection sensitivity of 5 × 10 2  cells/mL due to signal amplification unlike conventional naked dye FITC-Ab conjugate. Fluorescence of pyrene dye remained same on immobilization of biomolecules and nanoparticles showed stable fluorescent intensity under prolong exposure to laser owing to protective polymeric layer allowing accurate identification of bacteria. Surface-functionalized PC matrix and fluorescent label NPs permit covalent interactions among biomolecules enhancing signal acquisitions showing higher detection efficiency as compared to conventional microtiter plate-based system. Our novel immunoassay has the potential to be explored as rapid detection method for identifying S. typhi contaminations in water.Graphical Abstract

  10. Detection of Salmonella typhi utilizing bioconjugated fluorescent polymeric nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Swati, E-mail: swatijain.iitd@gmail.com; Chattopadhyay, Sruti, E-mail: sruticiitd@gmail.com; Jackeray, Richa; Abid, Zainul; Singh, Harpal, E-mail: harpal2000@yahoo.com [Centre for Biomedical Engineering, Indian Institute of Technology-Delhi (India)

    2016-05-15

    Present work demonstrates effective utilization of functionalized polymeric fluorescent nanoparticles as biosensing probe for the detection of Salmonella typhi bacteria on modified polycarbonate (PC) filters in about 3 h. Antibody modified-PC membranes were incubated with contaminated bacterial water for selective capturing which were detected by synthesized novel bioconjugate probe. Core–shell architecture of polymeric nanoparticles endows them with aqueous stabilization and keto-enolic functionalities making them usable for covalently linking S. typhi antibodies without any crosslinker or activator. Bradford analysis revealed that one nanoparticle has an average of 3.51 × 10{sup −19} g or 21 × 10{sup 4} bound S. typhi Ab molecules. Analysis of the regions of interest (ROI) in fluorescent micrographs of modified fluoroimmunoassay showed higher detection sensitivity of 5 × 10{sup 2} cells/mL due to signal amplification unlike conventional naked dye FITC-Ab conjugate. Fluorescence of pyrene dye remained same on immobilization of biomolecules and nanoparticles showed stable fluorescent intensity under prolong exposure to laser owing to protective polymeric layer allowing accurate identification of bacteria. Surface-functionalized PC matrix and fluorescent label NPs permit covalent interactions among biomolecules enhancing signal acquisitions showing higher detection efficiency as compared to conventional microtiter plate-based system. Our novel immunoassay has the potential to be explored as rapid detection method for identifying S. typhi contaminations in water.Graphical Abstract.

  11. Molecular engineering and fluorescence for the detection of toxic cations

    International Nuclear Information System (INIS)

    Souchon, V.

    2007-11-01

    This work is a part of the 'Toxicologie Nucleaire Environnementale' program which aims at studying the effects on the living of heavy metals or radionuclides involved in nuclear industry. Most particularly, it deals with the design of new fluorescent sensors for the selective detection of Pb 2+ , Cd 2+ and Cs + in biological media. Several fluorescent calixarenes possessing nitrogen atoms were synthesized and their properties as potential lead sensors were investigated. One of them could be used in experimental conditions close to biological media and new target compounds with amide functional groups were proposed. Many approaches were considered for the design of selective fluorescent sensors for cadmium. On the basis of literature results, many chelating compounds incorporating sulfur atoms were synthesized but showed no significant affinity towards cadmium. On the opposite, compounds functionalized with several pyridine-2'-yl-1,2,3-triazol fluorescent moieties linked to a β-cyclodextrin or a calix[4]arene showed good affinity for cadmium in methanol, but the selectivity was found to be insufficient. In contrast, very satisfying results in terms of both selectivity and sensitivity could be obtained with the commercial calcium sensor Rhod-5N in an aqueous medium at neutral pH. Lastly, micromolar detection limits for the selective detection of caesium were reached in an aqueous medium at neutral pH thanks to a new sulfonated fluorescent calixarene with two appended crown-ethers. An original complexation mechanism was proposed and validated by molecular modelling (DFT). (author)

  12. Detection of intaoral lesions using a fluorescence camera

    Science.gov (United States)

    Thoms, Michael

    2006-02-01

    Optical methods for the detection of carious lesions, calculus and plaque have the advantage of being minimally invasive. The use of endogeneous fluorescence markers like porphyrins could simplify the application of fluorescence techniques in the dental practice. It is known that porphyrins are produced by some of the bacterial species that are present in the oral cavity. Since porphyrins have an excitation band at about 400nm they have the potential to be used as fluorescent markers of locations in the oral cavity where the production of bacteria is out of the limits of healthy regions. Further, modern and efficient GaN-based semiconductor diodes emit light in this spectral range and thus make the implementation of fluorescence sensors with excitation at this wavelength easy. Carious lesions, calculus and plaque have been measured using a self build fluorescence camera using GaN-diodes for illumination at 405nm. Further, emission spectra under this excitation were recorded. For the latter purpose freshly extracted teeth were used. It has been found that already in the case of an initial carious lesion red porphyrin-fluorescence is emitted whereas it is absent in healthy enamel. In already brown coloured carious lesions the emission bands of porphyrin are present but the observed overall fluorescence intensity is lower, probably due to the absorption of the fluorescence by the carious defect itself. In dental calculus, dental plaque and subgingival concrements porphyrin originated luminescence was found as well. Since in these cases the emission spectra differ slightly it can be concluded that they originate from different types of porphyrins and thus also from different bacteria. These results show that this fluorescence technique can be a promising method to diagnose carious lesions, calculus and plaque.

  13. Research of the absorbance detection and fluorescence detection for multifunctional nutrition analyzer

    Science.gov (United States)

    Ni, Zhengyuan; Yan, Huimin; Ni, Xuxiang; Zhang, Xiuda

    2017-10-01

    The research of the multifunctional analyzer which integrates absorbance detection, fluorescence detection, time-resolved fluorescence detection, biochemical luminescence detection methods, can make efficient detection and analysis for a variety of human body nutrients. This article focuses on the absorbance detection and fluorescence detection system. The two systems are modular in design and controlled by embedded system, to achieve automatic measurement according to user settings. In the optical path design, the application of confocal design can improve the optical signal acquisition capability, and reduce the interference. A photon counter is used for detection, and a high performance counter module is designed to measure the output of photon counter. In the experiment, we use neutral density filters and potassium dichromate solution to test the absorbance detection system, and use fluorescein isothiocyanate FITC for fluorescence detection system performance test. The experimental results show that the absorbance detection system has a detection range of 0 4OD, and has good linearity in the detection range, while the fluorescence detection system has a high sensitivity of 1pmol/L concentration.

  14. Prenatal detection of aneuploidies using fluorescence in situ ...

    Indian Academy of Sciences (India)

    Unknown

    Fluorescence in situ hybridization (FISH) is a powerful molecular cytogenetic technique which allows rapid detection of aneuploidies on interphase cells and metaphase spreads. The aim of the present study was to evaluate FISH as a tool in prenatal diagnosis of aneuploidies in high risk pregnancies in an Indian set up.

  15. Detection of oxidative hair treatment using fluorescence microscopy.

    Science.gov (United States)

    Witt, Silvana; Wunder, Cora; Paulke, Alexander; Verhoff, Marcel A; Schubert-Zsilavecz, Manfred; Toennes, Stefan W

    2016-08-01

    In assessing abstinence from drug or alcohol abuse, hair analysis plays an important role. Cosmetic hair treatment influences the content of deposited drugs which is not always detectable during analysis. Since oxidation of melanin leads to an increase in fluorescence, a microscopic method was developed to distinguish natural from cosmetically treated hair. For validation, natural hair samples were treated with different types of cosmetics and inspected by fluorescence microscopy. Hair samples from 20 volunteers with documented cosmetic treatment and as a proof of concept 100 hair samples from forensic cases were analyzed by this method. Apart from autofluorescence with excitation at 365 nm, no obvious fluorescence was observed in untreated hair samples. Tinting and a natural plant product had no influence on fluorescence, but dyeing procedures including oxidation led to a marked increase in fluorescence. Proof of cosmetic treatment was achieved in hair samples from the 20 volunteers. In 100 forensic cases, 13 samples were characterized as oxidatively treated, which was in accordance with the respective disclosure except for one case where treatment was not admitted. This fluorescence microscopic procedure proved to be fast, easy, and reliable to identify oxidatively treated hair samples, which must be considered especially in evaluating cases of negative drug results. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Nondestructive fluorescent state detection of single neutral atom qubits.

    Science.gov (United States)

    Gibbons, Michael J; Hamley, Christopher D; Shih, Chung-Yu; Chapman, Michael S

    2011-04-01

    We demonstrate nondestructive (lossless) fluorescent state detection of individual neutral atom qubits trapped in an optical lattice. The hyperfine state of the atom is measured with a 95% accuracy and an atom loss rate of 1%. Individual atoms are initialized and detected over 100 times before being lost from the trap, representing a 100-fold improvement in data collection rates over previous experiments. Microwave Rabi oscillations are observed with repeated measurements of one and the same single atom. © 2011 American Physical Society

  17. Parallel detection experiment of fluorescence confocal microscopy using DMD.

    Science.gov (United States)

    Wang, Qingqing; Zheng, Jihong; Wang, Kangni; Gui, Kun; Guo, Hanming; Zhuang, Songlin

    2016-05-01

    Parallel detection of fluorescence confocal microscopy (PDFCM) system based on Digital Micromirror Device (DMD) is reported in this paper in order to realize simultaneous multi-channel imaging and improve detection speed. DMD is added into PDFCM system, working to take replace of the single traditional pinhole in the confocal system, which divides the laser source into multiple excitation beams. The PDFCM imaging system based on DMD is experimentally set up. The multi-channel image of fluorescence signal of potato cells sample is detected by parallel lateral scanning in order to verify the feasibility of introducing the DMD into fluorescence confocal microscope. In addition, for the purpose of characterizing the microscope, the depth response curve is also acquired. The experimental result shows that in contrast to conventional microscopy, the DMD-based PDFCM system has higher axial resolution and faster detection speed, which may bring some potential benefits in the biology and medicine analysis. SCANNING 38:234-239, 2016. © 2015 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  18. Pollution detection using the spectral fluorescent signatures (SFS technique

    Directory of Open Access Journals (Sweden)

    Mª Del Carmen Martín

    2014-06-01

    Full Text Available This work has been developed in the Applied Physics Department at the University of Vigo within the line of research based on the treatment of the degraded water by pollutants through the use of microalgae, reducing the emissions of greenhouse gases through the absorption of CO2 in the process and the reuse of biomass as biofuel. Remote sensing techniques have contributed to a great extent to the development of oil pollution monitoring systems. However, the available detection methods, mainly designed for spaceborne and airborne long distance inspection, are too expensive and complex to be used in an operational way by relatively unskilled personnel. In the framework of DEOSOM project (European AMPERA project, an innovative water monitoring method was proposed, in two steps: early oil spill detection using a portable shipborne laser-induced fluorescence LIDAR (LIF/LIDAR, and analysis of suspicious water samples in laboratory using the Spectral Fluorescent Signature (SFS technique. This work is focused on the second technique. This system aims to optimize the production of microalgae for biofuel and contaminant cleaning applications and was developed and tested in photo-bioreactors in the University of Vigo within the EnerBioAlgae project (SUDOE. In this project, the SFS technique was used as a diagnostic tool employing the fluorescence analyzer INSTANT-SCREENER M53UVC. The Spectral Fluorescence Signature technique (SFS is based on compounds fluorescence properties. The fluorescence intensity of a sample is measured at different excitation and emission wavelengths to produce a 3-dimensional fluorescence matrix, which can also be presented as a 2-dimensional color image where the color shows the intensity of the fluorescence. These matrices offer qualitative and quantitative information, since they can be useful for the identification of different substances from their characteristic excitation and emission spectra of fluorescence. They also

  19. Detection of DNA damage by comet fluorescence in situ hybridization.

    Science.gov (United States)

    Schlörmann, Wiebke; Glei, Michael

    2012-01-01

    Comet fluorescence in situ hybridization (Comet-FISH) is a useful method to detect overall and region-specific DNA damage in individual cells. Two well-established methods are combined, the Comet assay (single cell gel electrophoresis) and fluorescence in situ hybridization (FISH). The Comet assay is the method of choice for the detection of DNA damage. With the alkaline version the influence of specific substances such as water pollutants or ingredients of food on individual cells can be easily measured. The Comet assay involves the embedding of cells in agarose on microscopic slides, lysis of cells, and separation of DNA via electrophoresis. Damaged DNA migrates from the nucleus (head of the comet) forming a tail. The percentage of DNA in the tail correlates with the degree of DNA strand breaks (DNA damage). The combination of FISH with the Comet assay uses labeled probes which hybridize specifically to selected DNA sequences. This allows the detection of specific DNA damage or repair capacity in single cells. Here we present exemplarily the Comet-FISH method by detection of DNA damage using hydrogen peroxide as a genotoxic model substrate.

  20. Remote detection of nitrocompounds by laser-induced fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Simeonsson, J.B.; Barnes, E.M.; Mullane, M.; Pacquette, H.L. [Univ. of Iowa, Iowa City, IA (United States)

    1995-12-31

    Localized contaminations of subsurface soil and water by nitrocompounds is an environmental problem of great concern to the Department of Defense. Pollution by these materials is problematic because of the mutagenic and carcinogenic properties of not only the parent compounds, but also their microbial degradation products. Leaching of high explosives from munitions is the primary source of this contamination as nearly all high explosives include the nitro-(NO{sub 2}-) functionality in their molecular structure. Remediation of this problem is difficult, however, as there are no techniques available for the remote detection of these compounds. Currently emphasis is on the development of fiber optic coupled sensors which can be implemented in existing cone penentrometer (CPT) systems. Photofragmentation approaches are well suited to detecting classes of molecules and have been shown to be a very effective strategy for detecting nitrocompounds, especially when the NO fragment is targeted for detection. We are investigating a photofragmentation/laser-induced fluorescence (PF/LIF) approach for the remote detection and measurement of nitrocompounds that is fully compatible with fiber optic coupling. In our studies, single wavelength excitation has been used to (i) photofragment the parent compounds and (ii) probe the resulting photofragments to detect NO. Various wavelength schemes have been evaluated. Results will be presented to demonstrate the feasibility of a PF/LIF based sensor for the remote detection of nitrocompounds.

  1. Selective Detection of Neurotransmitters by Fluorescence and Chemiluminescence Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ziqiang Wang; Edward S. Yeung

    2001-08-06

    In recent years, luminescence imaging has been widely employed in neurochemical analysis. It has a number of advantages for the study of neuronal and other biological cells: (1) a particular molecular species or cellular constituent can be selectively visualized in the presence of a large excess of other species in a heterogeneous environment; (2) low concentration detection limits can be achieved because of the inherent sensitivity associated with fluorescence and chemiluminescence; (3) low excitation intensities can be used so that long-term observation can be realized while the viability of the specimen is preserved; and (4) excellent spatial resolution can be obtained with the light microscope so subcellular compartments can be identified. With good sensitivity, temporal and spatial resolution, the flux of ions and molecules and the distribution and dynamics of intracellular species can be measured in real time with specific luminescence probes, substrates, or with native fluorescence. A noninvasive detection scheme based on glutamate dehydrogenase (GDH) enzymatic assay combined with microscopy was developed to measure the glutamate release in cultured cells from the central nervous system (CNS). The enzyme reaction is very specific and sensitive. The detection limit with CCD imaging is down to {micro}M levels of glutamate with reasonable response time. They also found that chemiluminescence associated with the ATP-dependent reaction between luciferase and luciferin can be used to image ATP at levels down to 10 nM in the millisecond time scale. Similar imaging experiments should be feasible in a broad spectrum of biological systems.

  2. [Determination of trace bismuth in iron, steel and alloy by hydride generation-atomic fluorimetry].

    Science.gov (United States)

    Liu, Q

    2000-02-01

    With the aid of hydride generation-atomic fluorimetry, an analysis method by adding thiosemicarbazide-ascorbic acid and phosphoric acid to eliminate the interference of matrix has been developed for the determination of trace bismuth in iron, steel and alloy. The detection limit is Bi = 0.02 microgram.g-1 (3 sigma, n = 11, sample amount 0.2000 g). The method has been applied to determine trace arsenic in middle and low alloy steel, ferro and nickel-based superalloy, nickel-based superalloy, cobalt-based superalloy, copper alloy with satisfactory results.

  3. Chemical point detection using differential fluorescence from molecularly imprinted polymers

    Science.gov (United States)

    Pestov, Dmitry; Anderson, John E.; Nelson, Jean; Tepper, Gary C.

    2004-12-01

    Fluorescence represents one of the most attractive approaches for chemical sensing due to the abundant light produced by most fluorophores, resulting in excellent detection sensitivity. However, the broad and overlapping emission spectra of target and background species have made it difficult to perform species identification in a field instrument because of the need to perform spectral decomposition and analysis. This paper describes a new chemical sensing strategy based on differential fluorescence measurements from molecularly imprinted polymers, which eliminates the need to perform any spectral analysis. Species identification is accomplished by measuring the differential light output from a pair of polymers-one imprinted to a target species and the other identical, but not imprinted. The imprinted polymer selectively concentrates the target molecule and controls the energy (wavelength) of the emitted fluorescence signal and the differential output eliminates common mode signals associated with non-specific background interference. Because no spectral analysis is required, the sensors can be made extremely small and require very little power. Preliminary performance parameters from a prototype sensor are presented and discussed.

  4. Protein- protein interaction detection system using fluorescent protein microdomains

    Science.gov (United States)

    Waldo, Geoffrey S.; Cabantous, Stephanie

    2010-02-23

    The invention provides a protein labeling and interaction detection system based on engineered fragments of fluorescent and chromophoric proteins that require fused interacting polypeptides to drive the association of the fragments, and further are soluble and stable, and do not change the solubility of polypeptides to which they are fused. In one embodiment, a test protein X is fused to a sixteen amino acid fragment of GFP (.beta.-strand 10, amino acids 198-214), engineered to not perturb fusion protein solubility. A second test protein Y is fused to a sixteen amino acid fragment of GFP (.beta.-strand 11, amino acids 215-230), engineered to not perturb fusion protein solubility. When X and Y interact, they bring the GFP strands into proximity, and are detected by complementation with a third GFP fragment consisting of GFP amino acids 1-198 (strands 1-9). When GFP strands 10 and 11 are held together by interaction of protein X and Y, they spontaneous association with GFP strands 1-9, resulting in structural complementation, folding, and concomitant GFP fluorescence.

  5. Interest of Fluorescence Derivatization and Fluorescence Probe Assisted Post-column Detection of Phospholipids: A Short Review

    Directory of Open Access Journals (Sweden)

    Pratrice Prognon

    2010-01-01

    Full Text Available Phospholipids are essential constituents of all living cell membranes. There are many analytical methods available for the quantitative and qualitative determination of phospholipids, but since these molecules lack chromophores, common absorbance based methods are of limited use. Beside mass spectrometry, some less specific approaches that are routinely used are evaporative light scattering detection or fluorescence, which exhibit sufficient sensitivity. Here, we focus on fluorescence, which remains an interesting way to quantify phospholipids. Two ways of detecting phospholipids by fluorescence are possible coupled with separation techniques such as thin layer chromatography (TLC, high performance liquid chromatography (HPLC and capillary electrophoresis (CE: firstly, pre-column derivatization procedures and secondly, probe assisted post-column detection with suitable fluorescence reagents. In both cases, the common purpose is to increase the detection sensitivity. It is shown that, whereas pre-column derivatization is characterized by selectivity due to the chemical functionality of the analyte involved in the derivatization process, in supramolecular post-column derivatization, the selectivity only proceeds from the capacity of the lipid to involve supramolecular assemblies with a fluorescence probe. The aim of this review is to summarize available experiments concerning fluorescence detection of phospholipids. The interest and limitation of such detection approaches are discussed.

  6. Detection of dengue group viruses by fluorescence in situ hybridization

    Directory of Open Access Journals (Sweden)

    Raquin Vincent

    2012-10-01

    Full Text Available Abstract Background Dengue fever (DF and dengue hemorrhagic fever (DHF represent a global challenge in public health. It is estimated that 50 to 100 million infections occur each year causing approximately 20,000 deaths that are usually linked to severe cases like DHF and dengue shock syndrome. The causative agent of DF is dengue virus (genus Flavivirus that comprises four distinct serotypes (DENV-1 to DENV-4. Fluorescence in situ hybridization (FISH has been used successfully to detect pathogenic agents, but has not been implemented in detecting DENV. To improve our understanding of DENV infection and dissemination in host tissues, we designed specific probes to detect DENV in FISH assays. Methods Oligonucleotide probes were designed to hybridize with RNA from the broadest range of DENV isolates belonging to the four serotypes, but not to the closest Flavivirus genomes. Three probes that fit the criteria defined for FISH experiments were selected, targeting both coding and non-coding regions of the DENV genome. These probes were tested in FISH assays against the dengue vector Aedes albopictus (Diptera: Culicidae. The FISH experiments were led in vitro using the C6/36 cell line, and in vivo against dissected salivary glands, with epifluorescence and confocal microscopy. Results The three 60-nt oligonucleotides probes DENV-Probe A, B and C cover a broad range of DENV isolates from the four serotypes. When the three probes were used together, specific fluorescent signals were observed in C6/36 infected with each DENV serotypes. No signal was detected in either cells infected with close Flavivirus members West Nile virus or yellow fever virus. The same protocol was used on salivary glands of Ae. albopictus fed with a DENV-2 infectious blood-meal which showed positive signals in the lateral lobes of infected samples, with no significant signal in uninfected mosquitoes. Conclusion Based on the FISH technique, we propose a way to design and use

  7. Detection of vitellogenin incorporation into zebrafish oocytes by FITC fluorescence

    Directory of Open Access Journals (Sweden)

    Yokoi Hayato

    2011-04-01

    Full Text Available Abstract Background Large volumes of lymph can be collected from the eye-sacs of bubble-eye goldfish. We attempted to induce vitellogenin (Vtg in the eye-sac lymph of bubble-eye goldfish and develop a method for visualizing Vtg incorporation by zebrafish oocytes using FITC-labeling. Methods Estrogen efficiently induced Vtg in the eye-sac lymph of goldfish. After FITC-labeled Vtg was prepared, it was injected into mature female zebrafish. Results Incorporation of FITC-labeled Vtg by zebrafish oocytes was detected in in vivo and in vitro experiments. The embryos obtained from zebrafish females injected with FITC-labeled Vtg emitted FITC fluorescence from the yolk sac and developed normally. Conclusion This method for achieving Vtg incorporation by zebrafish oocytes could be useful in experiments related to the development and endocrinology of zebrafish oocytes.

  8. Laser-induced fluorescence detection strategies for sodium atoms and compounds in high-pressure combustors

    Science.gov (United States)

    Weiland, Karen J. R.; Wise, Michael L.; Smith, Gregory P.

    1993-01-01

    A variety of laser-induced fluorescence schemes were examined experimentally in atmospheric pressure flames to determine their use for sodium atom and salt detection in high-pressure, optically thick environments. Collisional energy transfer plays a large role in fluorescence detection. Optimum sensitivity, at the parts in 10 exp 9 level for a single laser pulse, was obtained with the excitation of the 4p-3s transition at 330 nm and the detection of the 3d-3p fluorescence at 818 nm. Fluorescence loss processes, such as ionization and amplified spontaneous emission, were examined. A new laser-induced atomization/laser-induced fluorescence detection technique was demonstrated for NaOH and NaCl. A 248-nm excimer laser photodissociates the salt molecules present in the seeded flames prior to atom detection by laser-induced fluorescence.

  9. Noninvasive skin fluorescence spectroscopy for detection of abnormal glucose tolerance

    Directory of Open Access Journals (Sweden)

    Edward L. Hull, PhD

    2014-09-01

    Full Text Available The ENGINE study evaluated noninvasive skin fluorescence spectroscopy (SFS for detection of abnormal glucose tolerance (AGT. The AGT detection performance of SFS was compared to fasting plasma glucose (FPG and hemoglobin A1C (A1C. The study was a head-to-head comparison of SFS to FPG and A1C in an at-risk population of 507 subjects, with no prior diagnosis of diabetes, each of whom received a 75 g, two-hour oral glucose tolerance test (OGTT. Subjects were measured by SFS on multiple days in fasting and non-fasting states. SFS data were acquired and analyzed with the SCOUT DS® device (VeraLight, Albuquerque, NM, USA. Disease truth was AGT, defined as OGTT ≥ 7.8 mmol/L. Sensitivity, false positive rate (FPR, ROC area, and equal error rate (EER for detection of AGT were computed. The reproducibility of SFS and FPG was assessed. The AGT sensitivity of SFS at the device's recommended screening threshold of 50 was 75.2%, higher than that of FPG (thresholds of 5.6 mmol/L or 6.1 mmol/L and A1C (thresholds of 5.7% or 6.0%. The SFS FPR was 42.1%, comparable to an A1C threshold of 5.7% (FPR = 43.5%. The EERs of SFS, FPG and A1C were similar, as were the partial ROC areas for FPRs of 20–50%. The reproducibility of SFS was 7.7% versus 8.1% for FPG. SFS had similar AGT detection performance to FPG and A1C and is a viable alternative to screening individuals for AGT.

  10. Fluorescence Probe Based on an Amino-Functionalized Fluorescent Magnetic Nanocomposite for Detection of Folic Acid in Serum.

    Science.gov (United States)

    Li, Xiaowan; Chen, Ligang

    2016-11-23

    A new fluorescence probe constructed with a multifunctional nanocomposite, Fe 3 O 4 -ZnS:Mn 2+ /SiO 2 -NH 2 , was successfully synthesized and then used to detect folic acid in real serum samples. The nanocomposite was characterized by fluorescence spectroscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray powder diffraction, and physical property measurement system. With the addition of analyte, the Fe 3 O 4 -ZnS:Mn 2+ /SiO 2 -NH 2 composite and folic acid formed a new complex because cross-linking of the amino and carboxyl groups participated in the condensation reaction. Then, the energy of quantum dots was transferred to the complex and led to quenching of the fluorescence. Moreover, the fluorescence intensity decreased significantly as the concentration of folic acid increased, and the fluorescence quenching ratio F 0 /F was related to the folic acid concentration in the range from 0.1 to 5 μg mL -1 . This method was used for detecting folic acid in real serum samples and gave recoveries in the range of 89.0%-96.0%, with relative standard deviations of 1.2%-3.9%. The detection limit was 9.6 ng mL -1 (S/N = 3). These satisfactory and simple results showed the great potential of this fluorescence probe in the field of pharmaceutical analysis.

  11. Ultrasensitive fluorescence immunoassay for detection of ochratoxin A using catalase-mediated fluorescence quenching of CdTe QDs

    Science.gov (United States)

    Huang, Xiaolin; Zhan, Shengnan; Xu, Hengyi; Meng, Xianwei; Xiong, Yonghua; Chen, Xiaoyuan

    2016-04-01

    Herein, for the first time we report an improved competitive fluorescent enzyme linked immunosorbent assay (ELISA) for the ultrasensitive detection of ochratoxin A (OTA) by using hydrogen peroxide (H2O2)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (QDs). In this immunoassay, catalase (CAT) was labeled with OTA as a competitive antigen to connect the fluorescence signals of the QDs with the concentration of the target. Through the combinatorial use of H2O2-induced fluorescence quenching of CdTe QDs as a fluorescence signal output and the ultrahigh catalytic activity of CAT to H2O2, our proposed method could be used to perform a dynamic linear detection of OTA ranging from 0.05 pg mL-1 to 10 pg mL-1. The half maximal inhibitory concentration was 0.53 pg mL-1 and the limit of detection was 0.05 pg mL-1. These values were approximately 283- and 300-folds lower than those of horseradish peroxidase (HRP)-based conventional ELISA, respectively. The reported method is accurate, highly reproducible, and specific against other mycotoxins in agricultural products as well. In summary, the developed fluorescence immunoassay based on H2O2-induced fluorescence quenching of CdTe QDs can be used for the rapid and highly sensitive detection of mycotoxins or haptens in food safety monitoring.Herein, for the first time we report an improved competitive fluorescent enzyme linked immunosorbent assay (ELISA) for the ultrasensitive detection of ochratoxin A (OTA) by using hydrogen peroxide (H2O2)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (QDs). In this immunoassay, catalase (CAT) was labeled with OTA as a competitive antigen to connect the fluorescence signals of the QDs with the concentration of the target. Through the combinatorial use of H2O2-induced fluorescence quenching of CdTe QDs as a fluorescence signal output and the ultrahigh catalytic activity of CAT to H2O2, our proposed method could be used to

  12. Fluorescent Receptor Binding Assay for Detecting Ciguatoxins in Fish.

    Science.gov (United States)

    Hardison, D Ransom; Holland, William C; McCall, Jennifer R; Bourdelais, Andrea J; Baden, Daniel G; Darius, H Taiana; Chinain, Mireille; Tester, Patricia A; Shea, Damian; Quintana, Harold A Flores; Morris, James A; Litaker, R Wayne

    2016-01-01

    Ciguatera fish poisoning is an illness suffered by > 50,000 people yearly after consumption of fish containing ciguatoxins (CTXs). One of the current methodologies to detect ciguatoxins in fish is a radiolabeled receptor binding assay (RBA(R)). However, the license requirements and regulations pertaining to radioisotope utilization can limit the applicability of the RBA(R) in certain labs. A fluorescence based receptor binding assay (RBA(F)) was developed to provide an alternative method of screening fish samples for CTXs in facilities not certified to use radioisotopes. The new assay is based on competition binding between CTXs and fluorescently labeled brevetoxin-2 (BODIPY®-PbTx-2) for voltage-gated sodium channel receptors at site 5 instead of a radiolabeled brevetoxin. Responses were linear in fish tissues spiked from 0.1 to 1.0 ppb with Pacific ciguatoxin-3C (P-CTX-3C) with a detection limit of 0.075 ppb. Carribean ciguatoxins were confirmed in Caribbean fish by LC-MS/MS analysis of the regional biomarker (C-CTX-1). Fish (N = 61) of six different species were screened using the RBA(F). Results for corresponding samples analyzed using the neuroblastoma cell-based assay (CBA-N2a) correlated well (R2 = 0.71) with those of the RBA(F), given the low levels of CTX present in positive fish. Data analyses also showed the resulting toxicity levels of P-CTX-3C equivalents determined by CBA-N2a were consistently lower than the RBA(F) affinities expressed as % binding equivalents, indicating that a given amount of toxin bound to the site 5 receptors translates into corresponding lower cytotoxicity. Consequently, the RBA(F), which takes approximately two hours to perform, provides a generous estimate relative to the widely used CBA-N2a which requires 2.5 days to complete. Other RBA(F) advantages include the long-term (> 5 years) stability of the BODIPY®-PbTx-2 and having similar results as the commonly used RBA(R). The RBA(F) is cost-effective, allows high sample

  13. Fluorescent Receptor Binding Assay for Detecting Ciguatoxins in Fish.

    Directory of Open Access Journals (Sweden)

    D Ransom Hardison

    Full Text Available Ciguatera fish poisoning is an illness suffered by > 50,000 people yearly after consumption of fish containing ciguatoxins (CTXs. One of the current methodologies to detect ciguatoxins in fish is a radiolabeled receptor binding assay (RBA(R. However, the license requirements and regulations pertaining to radioisotope utilization can limit the applicability of the RBA(R in certain labs. A fluorescence based receptor binding assay (RBA(F was developed to provide an alternative method of screening fish samples for CTXs in facilities not certified to use radioisotopes. The new assay is based on competition binding between CTXs and fluorescently labeled brevetoxin-2 (BODIPY®-PbTx-2 for voltage-gated sodium channel receptors at site 5 instead of a radiolabeled brevetoxin. Responses were linear in fish tissues spiked from 0.1 to 1.0 ppb with Pacific ciguatoxin-3C (P-CTX-3C with a detection limit of 0.075 ppb. Carribean ciguatoxins were confirmed in Caribbean fish by LC-MS/MS analysis of the regional biomarker (C-CTX-1. Fish (N = 61 of six different species were screened using the RBA(F. Results for corresponding samples analyzed using the neuroblastoma cell-based assay (CBA-N2a correlated well (R2 = 0.71 with those of the RBA(F, given the low levels of CTX present in positive fish. Data analyses also showed the resulting toxicity levels of P-CTX-3C equivalents determined by CBA-N2a were consistently lower than the RBA(F affinities expressed as % binding equivalents, indicating that a given amount of toxin bound to the site 5 receptors translates into corresponding lower cytotoxicity. Consequently, the RBA(F, which takes approximately two hours to perform, provides a generous estimate relative to the widely used CBA-N2a which requires 2.5 days to complete. Other RBA(F advantages include the long-term (> 5 years stability of the BODIPY®-PbTx-2 and having similar results as the commonly used RBA(R. The RBA(F is cost-effective, allows high sample

  14. A low-cost 2D fluorescence detection system for mm sized beads on-chip

    NARCIS (Netherlands)

    Segerink, Loes Irene; Koster, Maarten J.; Sprenkels, A.J.; van den Berg, Albert

    2012-01-01

    In this paper we describe a compact fluorescence detection system for on-chip analysis of beads, comprising a low-cost optical HD-DVD pickup. The complete system consists of a fluorescence detection unit, a control unit and a microfluidic chip containing microchannels and optical markers. With these

  15. Fluorescent Immunoassay Development for PrPSc Detection and Antemortem Diagnosis of TSEs

    National Research Council Canada - National Science Library

    Carp, Richard I

    2005-01-01

    ... fiber-based fluorescence detection system. By using magnetic beds-based immunocapture protocols, plasma PrP from normal and scrapie-infected animals was successfully isolated and can be detected directly by Western blot...

  16. A Fluorescence Based Miniaturized Detection Module for Toxin Producing Algae

    Science.gov (United States)

    Zieger, S. E.; Mistlberger, G.; Troi, L.; Lang, A.; Holly, C.; Klimant, I.

    2016-12-01

    Algal blooms are sensitive to external environmental conditions and may pose a serious threat to marine and human life having an adverse effect on the ecosystem. Harmful algal blooms can produce different toxins, which can lead to massive fish kills or to human disorders. Facing these problems, miniaturized and low-cost instrumentation for an early detection and identification of harmful algae classes has become more important over the last years. 1,2Based on the characteristic pigment pattern of different algae classes, we developed a miniaturized detection module, which is able to detect and identify algae classes after analyzing their spectral behavior. Our device combines features of a flow-cytometer and fluorimeter and is build up as a miniaturized and low-cost device of modular design. Similar to a fluorimeter, it excites cells in the capillary with up to 8 different excitation wavelengths recording the emitted fluorescence at 4 different emission channels. Furthermore, the device operates in a flow-through mode similar to a flow-cytometer, however, using only low-cost elements such as LEDs and photodiodes. Due to its miniaturized design, the sensitivity and selectivity increase, whereas background effects are reduced. With a sampling frequency of 140 Hz, we try to detect and count particular cell events even at a concentration of 2 cells / 7.3 µL illuminated volume. Using a self-learning multivariate algorithm, the data are evaluated autonomously on the device enabling an in-situ analysis. The flexibility in choosing excitation and emission wavelengths as well as the high sampling rate enables laboratory applications such as measuring induction kinetics. However, in its first application, the device is part of an open and modular monitoring system enabling the sensing of chemical compounds such as toxic and essential Hg, Cd, Pb, As and Cu trace metal species, nutrients and species related to the carbon cycle, VOCs and potentially toxic algae classes (FP7

  17. Electrophoresis microchip with integrated waveguides for simultaneous native UV fluorescence and absorbance detection

    DEFF Research Database (Denmark)

    Ohlsson, Pelle Daniel; Sala, Olga Ordeig; Mogensen, Klaus Bo

    2009-01-01

    Simultaneous label-free detection of UV absorbance and native UV-excited fluorescence in an electrophoresis microchip is presented. UV transparent integrated waveguides launch light at a wavelength of 254 nm from a mercury lamp along the length of a 1-mm. long detection cell. Transmitted UV light...... lid and by choosing a PMT insensitive to the excitation light. This way, the need for a fluorescence filter is eliminated. Calibration curves were measured for serotonin, tryptophan, propranolol and acetaminophen, and separations of the four compounds were demonstrated by electrophoresis and MEKC. All...... compounds could be detected in the micromolar range by absorbance detection, but fluorescence detection improved detection limits for compounds displaying native UV fluorescence up to ten times. The simultaneous detection also proved useful for the identification of compounds with similar retention times...

  18. Spectral and physiological information from chlorophyll fluorescence signals in the detection of pine damage

    Energy Technology Data Exchange (ETDEWEB)

    Meinander, O. [Finnish Meteorological Inst., Helsinki (Finland). Air Quality Dept.; Somersalo, S. [Helsinki Univ., Helsinki (Finland). Dept. of Plant Biology

    1995-12-31

    Photosynthesis is often among the first targets of the air pollution stress of plants. As chlorophyll fluorescence is a process competing with photosynthetic electron transport it can be employed to study the potential photosynthetic capacity and to detect damage to the photosynthetic apparatus. Many previous studies have shown that chlorophyll fluorescence can be a powerful tool in the detection of forest damage. In this preliminary study, singular value analysis of the fluorescence induction curves was used together with the traditional way of analyzing fluorescence measurements. The experimental data were collected from ozone and carbon dioxide fumigated Scots pine saplings. (author)

  19. Benzoxazinone kanamycin A conjugate. A new fluorescent probe suitable to detect mycoplasmas in cell culture.

    Science.gov (United States)

    Monsigny, M; Midoux, P; Depierreux, C; Bebear, C; Le Bris, M T; Valeur, B

    1990-01-01

    The synthesis of a new benzoxazinone derivative suitable to detect early infection of cultured cells with mycoplasmas is described. p-[beta-(7-dimethylamino 1,4-benzoxazin 2-one 3yl)-vinyl]- phenylpropenoic acid was coupled to kanamycin A, an aminoglycoside leading to a cationic fluorescent probe which fluoresces at 600 nm upon excitation at 490 nm. This fluorescent probe is shown to heavily label the glycocallix of all the mycoplasma strains tested which are found to be associated with contaminated cultured cells and to allow an easy and rapid detection of contamination by fluorescence microscopy and flow cytometry.

  20. Cutaneous porphyrins exhibit anti-stokes fluorescence that is detectable in sebum (Conference Presentation)

    Science.gov (United States)

    Tian, Giselle; Zeng, Haishan; Zhao, Jianhua; Wu, Zhenguo; Al Jasser, Mohammed; Lui, Harvey; Mclean, David I.

    2016-02-01

    Porphyrins produced by Propionibacterium acnes represent the principal fluorophore associated with acne, and appear as orange-red luminescence under the Wood's lamp. Assessment of acne based on Wood's lamp (UV) or visible light illumination is limited by photon penetration depth and has limited sensitivity for earlier stage lesions. Inducing fluorescence with near infrared (NIR) excitation may provide an alternative way to assess porphyrin-related skin disorders. We discovered that under 785 nm CW laser excitation PpIX powder exhibits fluorescence emission in the shorter wavelength range of 600-715 nm with an intensity that is linearly dependent on the excitation power. We attribute this shorter wavelength emission to anti-Stokes fluorescence. Similar anti-Stokes fluorescence was also detected focally in all skin-derived samples containing porphyrins. Regular (Stokes) fluorescence was present under UV and visible light excitation on ex vivo nasal skin and sebum from uninflamed acne, but not on nose surface smears or sebum from inflamed acne. Co-registered CW laser-excited anti-Stokes fluorescence and fs laser-excited multi-photon fluorescence images of PpIX powder showed similar features. In the skin samples because of the anti-Stokes effect, the NIR-induced fluorescence was presumably specific for porphyrins since there appeared to be no anti-Stokes emission signals from other typical skin fluorophores such as lipids, keratins and collagen. Anti-Stokes fluorescence under NIR CW excitation is more sensitive and specific for porphyrin detection than UV- or visible light-excited regular fluorescence and fs laser-excited multi-photon fluorescence. This approach also has higher image contrast compared to NIR fs laser-based multi-photon fluorescence imaging. The anti-Stokes fluorescence of porphyrins within sebum could potentially be applied to detecting and targeting acne lesions for treatment via fluorescence image guidance.

  1. Application of fluorescence spectroscopy and imaging in the detection of a photosensitizer in photodynamic therapy

    Science.gov (United States)

    Zang, Lixin; Zhao, Huimin; Zhang, Zhiguo; Cao, Wenwu

    2017-02-01

    Photodynamic therapy (PDT) is currently an advanced optical technology in medical applications. However, the application of PDT is limited by the detection of photosensitizers. This work focuses on the application of fluorescence spectroscopy and imaging in the detection of an effective photosenzitizer, hematoporphyrin monomethyl ether (HMME). Optical properties of HMME were measured and analyzed based on its absorption and fluorescence spectra. The production mechanism of its fluorescence emission was analyzed. The detection device for HMME based on fluorescence spectroscopy was designed. Ratiometric method was applied to eliminate the influence of intensity change of excitation sources, fluctuates of excitation sources and photo detectors, and background emissions. The detection limit of this device is 6 μg/L, and it was successfully applied to the diagnosis of the metabolism of HMME in the esophageal cancer cells. To overcome the limitation of the point measurement using fluorescence spectroscopy, a two-dimensional (2D) fluorescence imaging system was established. The algorithm of the 2D fluorescence imaging system is deduced according to the fluorescence ratiometric method using bandpass filters. The method of multiple pixel point addition (MPPA) was used to eliminate fluctuates of signals. Using the method of MPPA, SNR was improved by about 30 times. The detection limit of this imaging system is 1.9 μg/L. Our systems can be used in the detection of porphyrins to improve the PDT effect.

  2. Frequency domain diffuse fluorescence tomography for detection of deep lesions

    Science.gov (United States)

    Netz, Uwe J.; Gersonde, Ingo; Toelsner, Jan; Illing, Gerd

    2011-07-01

    In this paper we present two-dimensional phantom measurements of fluorescence light distribution in the frequency domain and reconstruction of three-dimensional fluorophore distribution. An experimental set-up was built up with two dimensional laser scanning, intensity modulation with frequencies up to 1 GHz, and two-dimensional imaging of modulated fluorescence light. Stable phantoms were developed simulating mammary tissue to perform measurements in a backscattering geometry for a variety of cylindrical fluorescence sources with different diameters, fluorophore concentrations, and surface distances at different modulation frequencies. At first calculated fluorescence light distributions from Monte-Carlo simulations was compared to measured data. In a second step from tomographic data sets of calculated fluorescent light, three-dimensional tomographic reconstructions of fluorophore distribution were performed. Finally three-dimensional tomographic reconstructions of fluorophore distribution were performed from tomographic fluorescence measurements. We found good concurrence between measured and calculated fluorescence distribution. Synthetic and real tomographic reconstruction showed good localization but underestimated the depth of fluorophore distribution.

  3. Detection of hepatocarcinoma in rats by integration of the fluorescence spectrum: Experimental model

    Science.gov (United States)

    Marcassa, J. C.; Ferreira, J.; Zucoloto, S.; Castro E Silva, O., Jr.; Marcassa, L. G.; Bagnato, V. S.

    2006-05-01

    The incorporation of spectroscopic techniques into diagnostic procedures may greatly improve the chances for precise diagnostics. One promising technique is fluorescence spectroscopy, which has recently been used to detect many different types of diseases. In this work, we use laser-induced tissue fluorescence to detect hepatocarcinoma in rats using excitation light at wavelengths of 443 and 532 nm. Hepatocarcinoma was induced chemically in Wistar rats. The collected fluorescence spectrum ranges from the excitation wavelength up to 850 nm. A mathematical procedure carried out on the spectrum determines a figure of merit value, which allows the detection of hepatocarcinoma. The figure of merit involves a procedure which evaluates the ratio between the backscattered excitation wavelength and the broad emission fluorescence band. We demonstrate that a normalization allowed by integration of the fluorescence spectra is a simple operation that may allow the detection of hepatocarcinoma.

  4. Homogenization optics to improve detectability of a fluorescence response to a single laser pulse: Detection of feces on apples

    Science.gov (United States)

    Fecal contamination of produce is a known food safety risk. Measuring fluorescence responses to UV excitation is an established method for detecting such contamination. One measurement system utilizes a pulsed UV laser to induce a fluorescence response from fecal material and a gated intensified cam...

  5. Fluorescent nanoparticles for the accurate detection of drug delivery

    NARCIS (Netherlands)

    Priem, Bram; Tian, Cheng; Tang, Jun; Zhao, Yiming; Mulder, Willem J. M.

    2015-01-01

    The application of intravenously administered nanoparticle (NP) therapies is increasingly being explored for a variety of diseases. The key to their success lies in a thorough understanding of nanoparticle pharmacological behavior, specificity and elimination kinetics. Fluorescent imaging techniques

  6. Screen-printed fluorescent sensors for rapid and sensitive anthrax biomarker detection

    International Nuclear Information System (INIS)

    Lee, Inkyu; Oh, Wan-Kyu; Jang, Jyongsik

    2013-01-01

    Highlights: •We fabricated flexible anthrax sensors with a simple screen-printing method. •The sensors selectively detected B. anthracis biomarker. •The sensors provide the visible alarm against anthrax attack. -- Abstract: Since the 2001 anthrax attacks, efforts have focused on the development of an anthrax detector with rapid response and high selectivity and sensitivity. Here, we demonstrate a fluorescence sensor for detecting anthrax biomarker with high sensitivity and selectivity using a screen-printing method. A lanthanide–ethylenediamine tetraacetic acid complex was printed on a flexible polyethersulfone film. Screen-printing deposition of fluorescent detecting moieties produced fluorescent patterns that acted as a visual alarm against anthrax

  7. Molecular engineering and fluorescence for the detection of toxic cations; Ingenierie moleculaire et fluorescence pour la reconnaissance de cations toxiques

    Energy Technology Data Exchange (ETDEWEB)

    Souchon, V

    2007-11-15

    This work is a part of the 'Toxicologie Nucleaire Environnementale' program which aims at studying the effects on the living of heavy metals or radionuclides involved in nuclear industry. Most particularly, it deals with the design of new fluorescent sensors for the selective detection of Pb{sup 2+}, Cd{sup 2+} and Cs{sup +} in biological media. Several fluorescent calixarenes possessing nitrogen atoms were synthesized and their properties as potential lead sensors were investigated. One of them could be used in experimental conditions close to biological media and new target compounds with amide functional groups were proposed. Many approaches were considered for the design of selective fluorescent sensors for cadmium. On the basis of literature results, many chelating compounds incorporating sulfur atoms were synthesized but showed no significant affinity towards cadmium. On the opposite, compounds functionalized with several pyridine-2'-yl-1,2,3-triazol fluorescent moieties linked to a {beta}-cyclodextrin or a calix[4]arene showed good affinity for cadmium in methanol, but the selectivity was found to be insufficient. In contrast, very satisfying results in terms of both selectivity and sensitivity could be obtained with the commercial calcium sensor Rhod-5N in an aqueous medium at neutral pH. Lastly, micromolar detection limits for the selective detection of caesium were reached in an aqueous medium at neutral pH thanks to a new sulfonated fluorescent calixarene with two appended crown-ethers. An original complexation mechanism was proposed and validated by molecular modelling (DFT). (author)

  8. Ratiometric Fluorescent Detection of Phosphate in Aqueous Solution Based on Near Infrared Fluorescent Silver Nanoclusters/Metal-Organic Shell Composite.

    Science.gov (United States)

    Dai, Cong; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2015-11-17

    Synthesis of near-infrared (NIR) fluorescent AgNCs with high quantum yield and stability is challenging but important for sensing and bioimaging application. Here, we report the fabrication of AgNCs/metal-organic shell composite via the deposition of metal-organic (zinc-nitrogen) coordination shell around AgNCs for ratiometric detection of phosphate. The composite exhibits NIR emission at 720 nm with 30 nm red-shift in comparison to bare AgNCs and a weak emission at 510 nm from the shell. The absolute quantum yield of NIR fluorescence of the composite is 15%, owing to FRET from the shell to the AgNCs core under the excitation at 430 nm. Besides, the composite is stable due to the protection of the shell. On the basis of the composite, a novel ratiometric fluorescence probe for the detection of phosphate in aqueous solution with good sensitivity and selectivity was developed. The limit of detection (3s) is 0.06 μM, and the relative standard deviation for 10 replicate detections of 10 μM phosphate was 0.6%. The recoveries of spiked phosphate in water, human urine, and serum samples ranged from 94.1% to 103.4%.

  9. Real-time detection of airborne fluorescent bioparticles in Antarctica

    Science.gov (United States)

    Crawford, Ian; Gallagher, Martin W.; Bower, Keith N.; Choularton, Thomas W.; Flynn, Michael J.; Ruske, Simon; Listowski, Constantino; Brough, Neil; Lachlan-Cope, Thomas; Fleming, Zoë L.; Foot, Virginia E.; Stanley, Warren R.

    2017-12-01

    We demonstrate, for the first time, continuous real-time observations of airborne bio-fluorescent aerosols recorded at the British Antarctic Survey's Halley VI Research Station, located on the Brunt Ice Shelf close to the Weddell Sea coast (lat 75°34'59'' S, long 26°10'0'' W) during Antarctic summer, 2015. As part of the NERC MAC (Microphysics of Antarctic Clouds) aircraft aerosol cloud interaction project, observations with a real-time ultraviolet-light-induced fluorescence (UV-LIF) spectrometer were conducted to quantify airborne biological containing particle concentrations along with dust particles as a function of wind speed and direction over a 3-week period. Significant, intermittent enhancements of both non- and bio-fluorescent particles were observed to varying degrees in very specific wind directions and during strong wind events. Analysis of the particle UV-induced emission spectra, particle sizes and shapes recorded during these events suggest the majority of particles were likely a subset of dust with weak fluorescence emission responses. A minor fraction, however, were likely primary biological particles that were very strongly fluorescent, with a subset identified as likely being pollen based on comparison with laboratory data obtained using the same instrument. A strong correlation of bio-fluorescent particles with wind speed was observed in some, but not all, periods. Interestingly, the fraction of fluorescent particles to total particle concentration also increased significantly with wind speed during these events. The enhancement in concentrations of these particles could be interpreted as due to resuspension from the local ice surface but more likely due to emissions from distal sources within Antarctica as well as intercontinental transport. Likely distal sources identified by back trajectory analyses and dispersion modelling were the coastal ice margin zones in Halley Bay consisting of bird colonies with likely associated high bacterial

  10. LED-Induced fluorescence and image analysis to detect stink bug damage in cotton bolls.

    Science.gov (United States)

    Mustafic, Adnan; Roberts, Erin E; Toews, Michael D; Haidekker, Mark A

    2013-02-20

    Stink bugs represent a major agricultural pest complex attacking more than 200 wild and cultivated plants, including cotton in the southeastern US. Stink bug feeding on developing cotton bolls will cause boll abortion or lint staining and thus reduced yield and lint value. Current methods for stink bug detection involve manual harvesting and cracking open of a sizable number of immature cotton bolls for visual inspection. This process is cumbersome, time consuming, and requires a moderate level of experience to obtain accurate estimates. To improve detection of stink bug feeding, we present here a method based on fluorescent imaging and subsequent image analyses to determine the likelihood of stink bug damage in cotton bolls. Damage to different structures of cotton bolls including lint and carpal wall can be observed under blue LED-induced fluorescence. Generally speaking, damaged regions fluoresce green, whereas non-damaged regions with chlorophyll fluoresce red. However, similar fluorescence emission is also observable on cotton bolls that have not been fed upon by stink bugs. Criteria based on fluorescent intensity and the size of the fluorescent spot allow to differentiate between true positives (fluorescent regions associated with stink bug feeding) and false positives (fluorescent regions due to other causes). We found a detection rates with two combined criteria of 87% for true-positive marks and of 8% for false-positive marks. The imaging technique presented herein gives rise to a possible detection apparatus where a cotton boll is imaged in the field and images processed by software. The unique fluorescent signature left by stink bugs can be used to determine with high probability if a cotton boll has been punctured by a stink bug. We believe this technique, when integrated in a suitable device, could be used for more accurate detection in the field and allow for more optimized application of pest control.

  11. LED-Induced fluorescence and image analysis to detect stink bug damage in cotton bolls

    Science.gov (United States)

    2013-01-01

    Background Stink bugs represent a major agricultural pest complex attacking more than 200 wild and cultivated plants, including cotton in the southeastern US. Stink bug feeding on developing cotton bolls will cause boll abortion or lint staining and thus reduced yield and lint value. Current methods for stink bug detection involve manual harvesting and cracking open of a sizable number of immature cotton bolls for visual inspection. This process is cumbersome, time consuming, and requires a moderate level of experience to obtain accurate estimates. To improve detection of stink bug feeding, we present here a method based on fluorescent imaging and subsequent image analyses to determine the likelihood of stink bug damage in cotton bolls. Results Damage to different structures of cotton bolls including lint and carpal wall can be observed under blue LED-induced fluorescence. Generally speaking, damaged regions fluoresce green, whereas non-damaged regions with chlorophyll fluoresce red. However, similar fluorescence emission is also observable on cotton bolls that have not been fed upon by stink bugs. Criteria based on fluorescent intensity and the size of the fluorescent spot allow to differentiate between true positives (fluorescent regions associated with stink bug feeding) and false positives (fluorescent regions due to other causes). We found a detection rates with two combined criteria of 87% for true-positive marks and of 8% for false-positive marks. Conclusions The imaging technique presented herein gives rise to a possible detection apparatus where a cotton boll is imaged in the field and images processed by software. The unique fluorescent signature left by stink bugs can be used to determine with high probability if a cotton boll has been punctured by a stink bug. We believe this technique, when integrated in a suitable device, could be used for more accurate detection in the field and allow for more optimized application of pest control. PMID:23421982

  12. Sensitive detection and separation of fluorescent derivatives using capillary electrophoresis with laser-induced fluorescence detection with 532nm Nd:YAG laser

    International Nuclear Information System (INIS)

    Vrabel, Patrik; Taborsky, Petr; Ryvolova, Marketa; Havel, Josef; Preisler, Jan

    2006-01-01

    Capillary electrophoresis with laser-induced fluorescence detection (CELIF) is a powerful tool for separation and sensitive determination of fluorescent species. Biologically active compounds, such as amino acids, peptides and proteins may exhibit native fluorescence, which is however often low and/or an expensive laser is required for excitation in UV. Therefore, labelling of the analytes with a fluorescent dye is usually necessary. In this work, a home-built CELIF instrument with diode pumped frequency-doubled continuous wave Nd:YAG excitation laser with feedback power regulation (532nm) was constructed. The suitability of this type of laser for LIF detection in a separation method was found excellent. A limit of detection (LOD) (S/N=3) of 2x10 -13 mol/l was achieved with rhodamine B, which is comparable to those obtained using similar instruments with Ar + laser [Y.F. Cheng, N.J. Dovichi, Science 242 (1988) 562, E.S. Yeung et al., J. Chromatogr. 608 (1992) 73]. LOD of a protein derivatized according to modified procedures [M.J. Little et al., Anal. Chim. Acta 339 (1997) 279, A. Chersi et al., Biochim. Biophys. Acta 1336 (1997) 83] was determined. Detection of the derivatives was found to be limited by insufficient reaction recovery at low analyte concentration, chemical noise, separation efficiency and quality of the derivatizing reagent rather than by the detector performance. As a consequence, a huge gap between the detection ability of CELIF instruments and LOD determined in real samples is revealed

  13. Design of a confocal microfluidic particle sorter using fluorescent photon burst detection

    NARCIS (Netherlands)

    Kunst, B.H.; Schots, A.; Visser, A.J.W.G.

    2004-01-01

    An instrumental system is described for detecting and sorting single fluorescent particles such as microspheres, bacteria, viruses, or even smaller macromolecules in a flowing liquid. The system consists of microfluidic chips (biochips), computer controlled high voltage power supplies, and a

  14. Cancer detection using NIR elastic light scattering and tissue fluorescence imaging

    Energy Technology Data Exchange (ETDEWEB)

    Demos, S G; Staggs, M; Radousky, H B; Gandour-Edwards, R; deVere White, R

    2000-12-04

    Near infrared imaging using elastic light scattering and tissue fluorescence under long-wavelength laser excitation are explored for cancer detection. Various types of normal and malignant human tissue samples were utilized in this investigation.

  15. Fluorescent Immunoassay Development for PrPSc Detection and Antemortem Diagnosis of TSEs

    National Research Council Canada - National Science Library

    Carp, Richard I

    2005-01-01

    The overall goal of our study is to develop methods of high-sensitivity and high-specificity for the antemortem diagnosis of prion diseases by detecting PrPSc in biological fluids using fluorescent immunoassay...

  16. Fluorescent Immunoassay Development for PrP(Sc) Detection and Antemortem Diagnosis of TSEs

    National Research Council Canada - National Science Library

    Carp, Richard I

    2004-01-01

    The overall goal of our study is to develop methods of high-sensitivity and high-specificity for the antemortem diagnosis of prion diseases by detecting PrPsc in biological fluids using fluorescent immunoassay...

  17. A graphitic carbon nitride based fluorescence resonance energy transfer detection of riboflavin.

    Science.gov (United States)

    Han, Jing; Zou, Hong Yan; Gao, Ming Xuan; Huang, Cheng Zhi

    2016-01-01

    Fluorescence resonance energy transfer (FRET), which occurs between two luminescent chromophores, can greatly improve the selectivity and sensitivity of a fluorescent assay when a ratiometric signaling with the fluorescence enhancement of the acceptor at the expense of the donor is adopted. In this study, a fluorescence ratiometric detection (FRD) of riboflavin (RF) has been made based on FRET, as the strong overlap occurred between the emission spectrum of graphitic carbon nitride (g-C3N4) and absorption spectrum of RF, in which g-C3N4 acts as the energy donor and RF as the energy acceptor. With increasing concentration of RF, the fluorescence intensity of g-C3N4 emission at 444 nm decreased and the fluorescence peak at 523 nm for RF increased regularly, making the fluorescence intensity ratio of 523 nm to 444 nm linearly dependent on the concentration of RF in the range from 0.4 μM to 10 μM, giving a limit of the detection of 170 nM. This method can be used to quantify RF in complex systems such as milk and drink, showing that the novel FRET-based fluorescence ratiometric detection can enable an attractive assay platform for analytes of interest. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Detection of vegetation stress from laser-induced fluorescence signatures

    International Nuclear Information System (INIS)

    Subhash, N.

    1995-01-01

    The in vivo laser-induced fluorescence (LIF) signatures of UV irradiated Salvia splendens plants were measured using an Optical Multichannel Analyser (OMA) system with Nitrogen laser excitation. The LIF spectra which consisted of the blue-green and the red chlorophyll bands were analysed with a non-linear interactive procedure using Gaussian spectral functions. The fluorescence intensity ratios of the various bands obtained from curve fitted parameters were found to be more sensitive to changes in the photosynthetic activity of the plant. The variation in the intensity ratio for the chlorophyll bands for nutrient stressed sunflower, cotton and groundnut plants as well as the nutrient and water stressed rice plants are also presented. It is observed that vegetation stress not only changes the fluorescence intensity ratios and the vitality index of the plant but also changes the peak position of the emission bands, in some cases. It is also seen that analysis of the fluorescence spectra in vegetation remote sensing applications would require a deconvolution procedure to evaluate the exact contribution of each band in the total spectra. (author). 23 refs, 8 figs, 5 tabs

  19. Performance of LED fluorescence microscopy for the detection of ...

    African Journals Online (AJOL)

    Introduction: Ziehl-Neelsen (ZN) bright-field microscopy is time-consuming, with poor sensitivity, even under optimal conditions. Introduction of Primo Star iLED fluorescent microscopy (FM) may improve TB case finding at referral hospitals in Rwanda. The study aimed to determine the acceptability and effectiveness of iLED ...

  20. Highly selective and sensitive fluorescent chemosensor for femtomolar detection of silver ion in aqueous medium

    OpenAIRE

    Arulraj, Abraham Daniel; Devasenathipathy, Rajkumar; Chen, Shen-Ming; Vasantha, Vairathevar Sivasamy; Wang, Sea-Fue

    2015-01-01

    The chemical sensing for the trace level detection of silver ion in aqueous solution still remains a challenge using simple, rapid, and inexpensive method. We report that thionine can be used as a fluorescent probe for the detection of Ag+ ion. The successive addition of Ag+ ion to the solution containing thionine quenches (turns-off) the fluorescence intensity of thionine. Association and quenching constants have been estimated by the Benesi–Hildebrand method and Stern–Volmer plot, respectiv...

  1. Photochemistry of Bisphenol-A Based Polycarbonate: Early Detection of Photoproducts by Fluorescence Spectroscopy

    Science.gov (United States)

    1993-07-13

    Reactor with 300 nm lamps. Figure 15b Expanded view of Figure 15a. Figure 16 UV - Visible spectra of salicylic acid (OD = 0.2 at 310 nm) in DCM for 0, 5...Mississippi, Hattiesburg, Mississippi 39406-0076. ABSTRACT The utility of fluorescence spectroscopy in detection of salicylic acid and 2,Z- biphenol type...1). In the ensuing discussion, we will describe a procedure which allows for detection via fluorescence spectroscopy of salicylic acid as well as

  2. Digitally synchronized LCD projector for multi-color fluorescence excitation in parallel capillary electrophoresis detection.

    Science.gov (United States)

    Lin, Shi-Wei; Chang, Chih-Hang; Wu, Dai-Yang; Lin, Che-Hsin

    2010-10-15

    A simple method is proposed for modulating the excitation light used for multi-color fluorescence detection in a single capillary electrophoresis (CE) channel. In the proposed approach, a low-cost commercial liquid crystal device (LCD) projector with digitally-modulated LCD switches is used to provide the illumination light source and the fluorescence emitted from the CE chip is synchronously detected using an ultraviolet-visible-near infrared (UV-vis-NIR) spectrometer. The modulated light source enables the detection of multiple fluorescence signals within a single CE channel without the need of mechanically switching optical components. In order to enhance the sensing performance of the proposed system, two short-pass filters and one band-pass filter are inserted into the LCD projector to modify the wavelength spectra for fluorescence excitation. With this simple approach, the signal-to-noise (SN) ratio of the fluorescence detection signals is greatly improved by a factor of approximately 22 when detecting Atto647N fluorescent dye. The feasibility of the proposed multi-color CE detection approach is demonstrated by detecting two different samples including a mixed sample comprising FITC, Rhodamine B and Atto647N fluorescent dyes and a bio-sample composed of two ssDNAs labeled with FITC and Cy3, respectively. Results confirm that the digitally-modulated excitation system proposed in this study has significant potential for the parallel analysis of fluorescently-labeled bio-samples using a multi-color detection scheme. Copyright © 2010 Elsevier B.V. All rights reserved.

  3. Fluorescent graphene quantum dot nanoprobes for the sensitive and selective detection of mercury ions.

    Science.gov (United States)

    Wang, Baojuan; Zhuo, Shujuan; Chen, Luyang; Zhang, Yongjun

    2014-10-15

    Graphene quantum dots were prepared by ultrasonic route and served as a highly selective water-soluble probe for sensing of Hg(2+). The fluorescence emission spectrum of graphene quantum dots was at about 430nm. In the presence of Hg(2+), the fluorescence of the quantum dots significantly quenched. And the fluorescence intensity gradually decreased with the increasing concentration of Hg(2+). The change of fluorescence intensity is directly proportional to the concentration of Hg(2+). Under optimum conditions, the linear range for the detection of Hg(2+) was 8.0×10(-7) to 9×10(-6)M with a detection limit of 1.0×10(-7)M. In addition, the preliminary mechanism of fluorescence quenching was discussed in the paper. The constructed sensor with high sensitivity and selectivity, simple, rapid properties makes it valuable for further application. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Improved in Vivo Whole-Animal Detection Limits of Green Fluorescent Protein–Expressing Tumor Lines by Spectral Fluorescence Imaging

    Directory of Open Access Journals (Sweden)

    Jenny M. Tam

    2007-07-01

    Full Text Available Green fluorescent protein (GFP has been used for cell tracking and imaging gene expression in superficial or surgically exposed structures. However, in vivo murine imaging is often limited by several factors, including scatter and attenuation with depth and overlapping autofluorescence. The autofluorescence signals have spectral profiles that are markedly different from the GFP emission spectral profile. The use of spectral imaging allows separation and quantitation of these contributions to the total fluorescence signal seen in vivo by weighting known pure component profiles. Separation of relative GFP and autofluorescence signals is not readily possible using epifluorescent continuous-wave single excitation and emission bandpass imaging (EFI. To evaluate detection thresholds using these two methods, nude mice were subcutaneously injected with a series of GFP-expressing cells. For EFI, optimized excitation and emission bandpass filters were used. Owing to the ability to separate autofluorescence contributions from the emission signal using spectral imaging compared with the mixed contributions of GFP and autofluorescence in the emission signal recorded by the EFI system, we achieved a 300-fold improvement in the cellular detection limit. The detection limit was 3 × 103 cells for spectral imaging versus 1 × 106 cells for EFI. Despite contributions to image stacks from autofluorescence, a 100-fold dynamic range of cell number in the same image was readily visualized. Finally, spectral imaging was able to separate signal interference of red fluorescent protein from GFP images and vice versa. These findings demonstrate the utility of the approach in detecting low levels of multiple fluorescent markers for whole-animal in vivo applications.

  5. [A cell-based detection of ciguatoxin using sodium fluorescence probe].

    Science.gov (United States)

    Yuan, Jian-hui; Yang, Hui; Tang, Huan-wen; Huang, Wei; Xu, Xin-yun; Liu, Jian-jun; Ke, Yue-bin; Cheng, Jin-quan; Zhuang, Zhi-xiong

    2011-04-01

    To establish a cell-based detection method of ciguatoxin using fluorescence assay. Mouse neuroblastoma N-2A cells were exposed to ouabain and veratridine and different concentrations of standard ciguatoxin samples (P-CTX-1) to establish the curvilinear relationship between the toxin dosage and fluorescence intensity using the sodium fluorescence probe CoroNaTM Green. The toxicity curvilinear relationship was also generated between the toxin dosage and cell survival using CCK-8 method. Based on these standard curves, the presence of ciguatoxin was detected in 33 samples of deep-sea coral fish. A correlation was found between the detection results of cell-based fluorescence assay and cytotoxicity assay, whose detection limit reached 103 g/ml and 1012 g/ml, respectively. The cell-based fluorescent assay sensitivity showed a higher sensitivity than cytotoxicity assay with a 2-4 h reduction of the detection time. The cell-based fluorescent assay can quickly and sensitively detect ciguatoxin and may serve as a good option for preliminary screening of the toxin.

  6. Detection of reactive oxygen species in mainstream cigarette smoke by a fluorescent probe

    Science.gov (United States)

    Liu, Li; Xu, Shi-jie; Li, Song-zhan

    2009-07-01

    A mass of reactive oxygen species(ROS) are produced in the process of smoking. Superfluous ROS can induce the oxidative stress in organism, which will cause irreversible damage to cells. Fluorescent probe is taken as a marker of oxidative stress in biology and has been applied to ROS detection in the field of biology and chemistry for high sensitivity, high simplicity of data collection and high resolution. As one type of fluorescent probe, dihydrorhodamine 6G (dR6G) will be oxidized to the fluorescent rhodamine 6G, which could be used to detect ROS in mainstream cigarette smoke. We investigated the action mechanism of ROS on dR6G, built up the standard curve of R6G fluorescence intensity with its content, achieved the variation pattern of R6G fluorescence intensity with ROS content in mainstream cigarette smoke and detected the contents of ROS from the 4 types of cigarettes purchased in market. The result shows that the amount of ROS has close relationship with the types of tobacco and cigarette production technology. Compared with other detecting methods such as electronic spin resonance(ESR), chromatography and mass spectrometry, this detection method by the fluorescent probe has higher efficiency and sensitivity and will have wide applications in the ROS detection field.

  7. Fabrication of AO/LDH fluorescence composite and its detection of Hg2+in water.

    Science.gov (United States)

    Liu, Meng; Lv, Guocheng; Mei, Lefu; Wei, Yanke; Liu, Jieyuan; Li, Zhaohui; Liao, Libing

    2017-10-17

    Divalent mercury ion (Hg 2+ ) is one of the most common pollutants in water with high toxicity and significant bioaccumulation, for which sensitive and selective detection methods are highly necessary to carry out its detection and quantification. Fluorescence detection by organic dyes is a simple and rapid method in pollutant analyses and is limited because of quenching caused by aggregation dye molecules. Hydrotalcite (LDH) is one of the most excellent carrier materials. In this study, an organic dye acridine orange (AO) was successfully loaded on the LDH layers, which significantly inhibited fluorescence quenching of AO. The composite AO/LDH reaches the highest fluorescence intensity when the AO initial concentration is 5 mg/L. With its enhanced fluorescent property, the composite powder was fabricated to fluorescence test papers. The maximal fluorescence intensity was achieved with a pulp to AO/LDH ratio of 1:5 which can be used to detect Hg 2+ in water by naked eyes. Hg 2+ in aqueous solution can be detected by instruments in the range of 0.5 to 150 mM. The novelty of this study lies on both the development of a new type of mineral-dye composite material, as well as its practical applications for fast detection.

  8. "Turn-on" fluorescent probe for detection of H2S and its applications in bioimaging

    Science.gov (United States)

    Zhao, Qi; Kang, Jin; Wen, Ying; Huo, Fangjun; Zhang, Yongbin; Yin, Caixia

    2018-01-01

    A novel fluorescent probe (named YQ-1) containing disulfide-bond coumarin derivative was developed for H2S. In response to H2S, YQ-1 showed remarkable fluorescent emission enhancement at 462 nm. Besides, YQ-1 exhibited higher selectivity, faster response rate, low cytotoxicity and low detection limit (0.052 μM). Further, YQ-1 was used to detect the presence of H2S level in living A549 cells, indicating YQ-1 has good membrane permeability and fluorescence properties.

  9. Green fluorescent protein-doped sol-gel silica planar waveguide to detect organophosphorus compound

    Science.gov (United States)

    Enami, Y.; Suye, S.

    2012-02-01

    We report novel living protein-doped planar waveguide, and real-time detection of an organophosphorus compound using a sol-gel silica planar waveguide doped with a green fluorescent protein and an organophosphorus hydrolase on a yeast-cell surface. The waveguide was pumped at 488 nm, and emitted green fluorescence at the far field. The green fluorescent light at 550 nm changed by 50% from the original power 1 min after application of the organophosphorus compound. The results enable the real-time detection of biochemical weapon and insecticide harmful for human body by using an in-line fiber sensor network.

  10. High sensitivity fluorescent single particle and single molecule detection apparatus and method

    Science.gov (United States)

    Mathies, Richard A.; Peck, Konan; Stryer, Lubert

    1990-01-01

    Apparatus is described for ultrasensitive detection of single fluorescent particles down to the single fluorescent molecule limit in a fluid or on a substrate comprising means for illuminating a predetermined volume of the fluid or area of the substrate whereby to emit light including background light from the fluid and burst of photons from particles residing in the area. The photon burst is detected in real time to generate output representative signal. The signal is received and the burst of energy from the fluorescent particles is distinguished from the background energy to provide an indication of the number, location or concentration of the particles or molecules.

  11. A ratiometric nanoprobe based on silver nanoclusters and carbon dots for the fluorescent detection of biothiols

    Science.gov (United States)

    Zhang, Shuming; Lin, Bixia; Yu, Ying; Cao, Yujuan; Guo, Manli; Shui, Lingling

    2018-04-01

    Ratiometric fluorescent probes could eliminate the influence from experimental factors and improve the detection accuracy. In this article, a ratiometric nanoprobe was constructed based on silver nanoclusters (AgNCs) with nitrogen-doped carbon dots (NCDs) and used for the detection of biothiols. The fluorescence peak of AgNCs was observed at 650 nm with excitation wavelength at 370 nm. In order to construct the ratiometric fluorescent probe, NCDs with the excitation and emission wavelengths at 370 nm and 450 nm were selected. After adding AgNCs, the fluorescence of NCDs was quenched. The mechanism of the fluorescence quenching was studied by fluorescence, UV-Vis absorption and the fluorescence lifetime spectra. The results indicated that the quenching could be ascribed to the inner filter effect (IFE). With the addition of biothiols, the fluorescence of AgNCs at 650 nm decreased due to the breakdown of AgNCs, and the fluorescence of NCDs at 450 nm recovered accordingly. Thus, the relationship between the ratio of the fluorescence intensities (I450/I650) and biothiol concentration was used to establish the determination method for biothiols. Cysteine (Cys) was taken as the model of biothiols, and the working curve for Cys was I450/I650 = 0.60CCys - 1.86 (CCys: μmol/L) with the detection limit of 0.14 μmol/L (S/N = 3). Then, the method was used for the detection of Cys in human urine and serum samples with satisfactory accuracy and recovery ratios. Furthermore, the probe could be applied for the visual semi-quantitative determination of Cys by naked eyes.

  12. Detection of proximal caries using quantitative light-induced fluorescence-digital and laser fluorescence: a comparative study.

    Science.gov (United States)

    Yoon, Hyung-In; Yoo, Min-Jeong; Park, Eun-Jin

    2017-12-01

    The purpose of this study was to evaluate the in vitro validity of quantitative light-induced fluorescence-digital (QLF-D) and laser fluorescence (DIAGNOdent) for assessing proximal caries in extracted premolars, using digital radiography as reference method. A total of 102 extracted premolars with similar lengths and shapes were used. A single operator conducted all the examinations using three different detection methods (bitewing radiography, QLF-D, and DIAGNOdent). The bitewing x-ray scale, QLF-D fluorescence loss (ΔF), and DIAGNOdent peak readings were compared and statistically analyzed. Each method showed an excellent reliability. The correlation coefficient between bitewing radiography and QLF-D, DIAGNOdent were -0.644 and 0.448, respectively, while the value between QLF-D and DIAGNOdent was -0.382. The kappa statistics for bitewing radiography and QLF-D had a higher diagnosis consensus than those for bitewing radiography and DIAGNOdent. The QLF-D was moderately to highly accurate (AUC = 0.753 - 0.908), while DIAGNOdent was moderately to less accurate (AUC = 0.622 - 0.784). All detection methods showed statistically significant correlation and high correlation between the bitewing radiography and QLF-D. QLF-D was found to be a valid and reliable alternative diagnostic method to digital bitewing radiography for in vitro detection of proximal caries.

  13. Sensitive detection of alkaline phosphatase by switching on gold nanoclusters fluorescence quenched by pyridoxal phosphate.

    Science.gov (United States)

    Halawa, Mohamed Ibrahim; Gao, Wenyue; Saqib, Muhammad; Kitte, Shimeles Addisu; Wu, Fengxia; Xu, Guobao

    2017-09-15

    In this work, we designed highly sensitive and selective luminescent detection method for alkaline phosphatase using bovine serum albumin functionalized gold nanoclusters (BSA-AuNCs) as the nanosensor probe and pyridoxal phosphate as the substrate of alkaline phosphatase. We found that pyridoxal phosphate can quench the fluorescence of BSA-AuNCs and pyridoxal has little effect on the fluorescence of BSA-AuNCs. The proposed mechanism of fluorescence quenching by PLP was explored on the basis of data obtained from high-resolution transmission electron microscopy (HRTEM), dynamic light scattering (DLS), UV-vis spectrophotometry, fluorescence spectroscopy, fluorescence decay time measurements and circular dichroism (CD) spectroscopy. Alkaline phosphatase catalyzes the hydrolysis of pyridoxal phosphate to generate pyridoxal, restoring the fluorescence of BSA-AuNCs. Therefore, a recovery type approach has been developed for the sensitive detection of alkaline phosphatase in the range of 1.0-200.0U/L (R 2 =0.995) with a detection limit of 0.05U/L. The proposed sensor exhibit excellent selectivity among various enzymes, such as glucose oxidase, lysozyme, trypsin, papain, and pepsin. The present switch-on fluorescence sensing strategy for alkaline phosphatase was successfully applied in human serum plasma with good recoveries (100.60-104.46%), revealing that this nanosensor probe is a promising tool for ALP detection. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Improved murine glioma detection following modified diet and photobleaching of skin PpIX fluorescence

    Science.gov (United States)

    Gibbs, Summer L.; O'Hara, Julia A.; Hoopes, P. Jack; Pogue, Brian W.

    2007-02-01

    The Aminolevulinic Acid (ALA) - Protoporphyrin IX (PpIX) system is unique in the world of photosensitizers in that the prodrug ALA is enzymatically transformed via the tissue of interest into fluorescently detectable levels of PpIX. This system can be used to monitor cellular metabolism of tumor tissue for applications such as therapy monitoring. Detecting PpIX fluorescence noninvasively has proven difficult due to the high levels of PpIX produced in the skin compared to other tissue both with and without ALA administration. In the current study, methods to decrease skin PpIX autofluorescence and skin PpIX fluorescence following ALA administration have been examined. Use of a purified diet is found to decrease both skin PpIX autofluorescence and skin PpIX fluorescence following ALA administration, while addition of a broad spectrum antibiotic to the water shows little effect. Following ALA administration, improved brain tumor detection is seen when skin PpIX fluorescence is photobleached via blue light prior to transmission spectroscopic measurements of tumor bearing and control animals. Both of these methods to decrease skin PpIX autofluorescence and skin PpIX fluorescence following ALA administration are shown to have a large effect on the ability to detect tumor tissue PpIX fluorescence noninvasively in vivo.

  15. Turn-on fluorescence detection of H2O2 and TATP.

    Science.gov (United States)

    Germain, Meaghan E; Knapp, Michael J

    2008-11-03

    Peroxide-based explosives, like triacetone triperoxide (TATP), are important targets for detection because of their broad use in improvised explosives but pose challenges. We report a highly sensitive turn-on fluorescence detection for H2O2 and organic peroxides, including TATP. The detection strategy relies on oxidative deboronation to unmask H2Salen, which subsequently binds Zn(2+) to form fluorescent Zn(Salen). Sensitivity is excellent, with detection limits below 10 nM for H2O2, TATP, and benzoyl peroxide. In addition, acid treatment is necessary to sense TATP, suggesting the potential to discriminate between H2O2 and TATP based upon minimal sample pretreatment.

  16. Detection of mechanical and disease stresses in citrus plants by fluorescence spectroscopy

    Science.gov (United States)

    Belasque, J., Jr.; Gasparoto, M. C. G.; Marcassa, L. G.

    2008-04-01

    We have investigated the detection of mechanical and disease stresses in citrus plants (Citrus limonia [L.] Osbeck) using laser-induced fluorescence spectroscopy. Due to its economic importance we have chosen to investigate the citrus canker disease, which is caused by the Xanthomonas axonopodis pv. citri bacteria. Mechanical stress was also studied because it plays an important role in the plant's infection by such bacteria. A laser-induced fluorescence spectroscopy system, composed of a spectrometer and a 532 nm10 mW excitation laser was used to perform fluorescence spectroscopy. The ratio of two chlorophyll fluorescence bands allows us to detect and discriminate between mechanical and disease stresses. This ability to discriminate may have an important application in the field to detect citrus canker infected trees.

  17. Bifunctional fluorescent probes for detection of amyloid aggregates and reactive oxygen species

    Science.gov (United States)

    Needham, Lisa-Maria; Weber, Judith; Fyfe, James W. B.; Kabia, Omaru M.; Do, Dung T.; Klimont, Ewa; Zhang, Yu; Rodrigues, Margarida; Dobson, Christopher M.; Ghandi, Sonia; Bohndiek, Sarah E.; Snaddon, Thomas N.; Lee, Steven F.

    2018-02-01

    Protein aggregation into amyloid deposits and oxidative stress are key features of many neurodegenerative disorders including Parkinson's and Alzheimer's disease. We report here the creation of four highly sensitive bifunctional fluorescent probes, capable of H2O2 and/or amyloid aggregate detection. These bifunctional sensors use a benzothiazole core for amyloid localization and boronic ester oxidation to specifically detect H2O2. We characterized the optical properties of these probes using both bulk fluorescence measurements and single-aggregate fluorescence imaging, and quantify changes in their fluorescence properties upon addition of amyloid aggregates of α-synuclein and pathophysiological H2O2 concentrations. Our results indicate these new probes will be useful to detect and monitor neurodegenerative disease.

  18. Fluorescent QDs-polystyrene composite nanospheres for highly efficient and rapid protein antigen detection

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Changhua; Mao, Mao [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China); Yuan, Hang [Tsinghua University, Life Science Division, Graduate School at Shenzhen (China); Shen, Huaibin [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China); Wu, Feng; Ma, Lan, E-mail: malan@sz.tsinghua.edu.cn [Tsinghua University, Life Science Division, Graduate School at Shenzhen (China); Li, Lin Song, E-mail: lsli@henu.edu.cn [Henan University, Key Laboratory for Special Functional Materials of the Ministry of Education (China)

    2013-09-15

    In this paper, high-quality carboxyl-functionalized fluorescent (red, green, and blue emitting) nanospheres (46-103 nm) consisting of hydrophobic quantum dots (QDs) and polystyrene were prepared by a miniemulsion polymerization approach. This miniemulsion polymerization approach induced a homogeneous distribution and high aqueous-phase transport efficiency of fluorescent QDs in composite nanospheres, which proved the success of our encoding QDs strategy. The obtained fluorescent nanospheres exhibited high stability in aqueous solution under a wide range of pH, different salt concentrations, PBS buffer, and thermal treatment at 80 Degree-Sign C. Based on the red emitting composite nanosphere, we performed fluorescent lateral flow immunoassay (LFIA) strips for high-sensitivity and rapid alpha-fetal protein detection. The detection limit reached 0.1 ng/mL, which was 200 times higher than commercial colloidal gold-labeled LFIA strips, and it reached similar detection level in enzyme-linked immunosorbent assay kit.

  19. Fluorescent QDs-polystyrene composite nanospheres for highly efficient and rapid protein antigen detection

    Science.gov (United States)

    Zhou, Changhua; Mao, Mao; Yuan, Hang; Shen, Huaibin; Wu, Feng; Ma, Lan; Li, Lin Song

    2013-09-01

    In this paper, high-quality carboxyl-functionalized fluorescent (red, green, and blue emitting) nanospheres (46-103 nm) consisting of hydrophobic quantum dots (QDs) and polystyrene were prepared by a miniemulsion polymerization approach. This miniemulsion polymerization approach induced a homogeneous distribution and high aqueous-phase transport efficiency of fluorescent QDs in composite nanospheres, which proved the success of our encoding QDs strategy. The obtained fluorescent nanospheres exhibited high stability in aqueous solution under a wide range of pH, different salt concentrations, PBS buffer, and thermal treatment at 80 °C. Based on the red emitting composite nanosphere, we performed fluorescent lateral flow immunoassay (LFIA) strips for high-sensitivity and rapid alpha-fetal protein detection. The detection limit reached 0.1 ng/mL, which was 200 times higher than commercial colloidal gold-labeled LFIA strips, and it reached similar detection level in enzyme-linked immunosorbent assay kit.

  20. Synthesis and characterization of near IR fluorescent albumin nanoparticles for optical detection of colon cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Sarit; Pellach, Michal [Department of Chemistry, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 52900 (Israel); Kam, Yossi [Institute for Drug Research, School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, P.O. Box 12065, Jerusalem 91120 (Israel); Grinberg, Igor; Corem-Salkmon, Enav [Department of Chemistry, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 52900 (Israel); Rubinstein, Abraham [Institute for Drug Research, School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, P.O. Box 12065, Jerusalem 91120 (Israel); Margel, Shlomo, E-mail: shlomo.margel@mail.biu.ac.il [Department of Chemistry, Bar-Ilan Institute of Nanotechnology and Advanced Materials, Bar-Ilan University, Ramat-Gan 52900 (Israel)

    2013-03-01

    Near IR (NIR) fluorescent human serum albumin (HSA) nanoparticles hold great promise as contrast agents for tumor diagnosis. HSA nanoparticles are considered to be biocompatible, non-toxic and non-immunogenic. In addition, NIR fluorescence properties of these nanoparticles are important for in vivo tumor diagnostics, with low autofluorescence and relatively deep penetration of NIR irradiation due to low absorption of biomatrices. The present study describes the synthesis of new NIR fluorescent HSA nanoparticles, by entrapment of a NIR fluorescent dye within the HSA nanoparticles, which also significantly increases the photostability of the dye. Tumor-targeting ligands such as peanut agglutinin (PNA) and anti-carcinoembryonic antigen antibodies (anti-CEA) were covalently conjugated to the NIR fluorescent albumin nanoparticles, increasing the potential fluorescent signal in tumors with upregulated corresponding receptors. Specific colon tumor detection by the NIR fluorescent HSA nanoparticles was demonstrated in a chicken embryo model and a rat model. In future work we also plan to encapsulate cancer drugs such as doxorubicin within the NIR fluorescent HSA nanoparticles for both colon cancer imaging and therapy. - Highlights: Black-Right-Pointing-Pointer Near IR human serum albumin nanoparticles were synthesized and characterized. Black-Right-Pointing-Pointer Nanoparticles were shown to be physically and chemically stable and photostable. Black-Right-Pointing-Pointer Tumor-targeting ligands were covalently conjugated to the nanoparticles. Black-Right-Pointing-Pointer Specific colon cancer tumor detection was demonstrated in chicken-embryo and rat models.

  1. Molecularly imprinted fluorescent probe based on FRET for selective and sensitive detection of doxorubicin

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhifeng, E-mail: 897061147@qq.com [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Deng, Peihong; Li, Junhua [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China); Xu, Li [Department of Applied Chemistry, College of Materials and Energy, South China Agricultural University, Guangzhou 510642 (China); Tang, Siping [College of Chemistry and Materials Science, Hengyang Normal University, Key Laboratory of Functional Organometallic Materials of Hunan Province University, Hengyang 421008 (China)

    2017-04-15

    Highlights: • FRET-based molecularly imprinted probe for detection of doxorubicin was prepared. • The detection limit of the probe was 13.8 nM for doxorubicin. • The FRET-based probe had a higher selectivity for the template than ordinary MIMs. - Abstract: In this work, a new type of fluorescent probe for detection of doxorubicin has been constructed by the combined use of fluorescence resonance energy transfer (FRET) technology and molecular imprinting technique (MIT). Using doxorubicin as the template, the molecularly imprinted polymer thin layer was fabricated on the surfaces of carbon dot (CD) modified silica by sol-gel polymerization. The excitation energy of the fluorescent donor (CDs) could be transferred to the fluorescent acceptor (doxorubicin). The FRET based fluorescent probe demonstrated high sensitivity and selectivity for doxorubicin. The detection limit was 13.8 nM. The fluorescent probe was successfully applied for detecting doxorubicin in doxorubicin-spiked plasmas with a recovery of 96.8–103.8%, a relative standard deviation (RSD) of 1.3–2.8%. The strategy for construction of FRET-based molecularly imprinted materials developed in this work is very promising for analytical applications.

  2. Chair-side detection of Prevotella Intermedia in mature dental plaque by its fluorescence.

    Science.gov (United States)

    Nomura, Yoshiaki; Takeuchi, Hiroaki; Okamoto, Masaaki; Sogabe, Kaoru; Okada, Ayako; Hanada, Nobuhiro

    2017-06-01

    Prevotella intermedia/nigrescens is one of the well-known pathogens causing periodontal diseases, and the red florescence excited by the visible blue light caused by the protoporphyrin IX in the bacterial cells could be useful for the chair-side detection. The aim of this study was to evaluated levels of periodontal pathogen, especially P. intermedia in clinical samples of red fluorescent dental plaque. Thirty two supra gingival plaque samples from six individuals were measured its fluorescence at 640nm wavelength excited by 409nm. Periodontopathic bacteria were counted by the Invader PLUS PCR assay. Co-relations the fluorescence intensity and bacterial counts were analyzed by Person's correlation coefficient and simple and multiple regression analysis. Positive and negative predictive values of the fluorescence intensities for with or without P. intermedia in supragingival plaque was calculated. When relative fluorescence unit (RFU) were logarithmic transformed, statistically significant linear relations between RFU and bacterial counts were obtained for P. intermedia, Porphyromonas gingivalis and Tannerella forsythia. By the multiple regression analysis, only P. intermedia had statistically significant co-relation with fluorescence intensities. All of the fluorescent dental plaque contained P. intermedia m. In contrast, 28% of non-fluorescent plaques contained P. intermedia. To check the fluorescence dental plaque in the oral cavity could be the simple chair-side screening of the mature dental plaque before examining the periodontal pathogens especially P. intermedia by the PCR method. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Oligonucleotide-stabilized fluorescent silver nanoclusters for the specific and sensitive detection of biotin.

    Science.gov (United States)

    Xiong, Xiaoli; Tang, Yan; Zhao, Jingjin; Zhao, Shulin

    2016-02-21

    A novel biotin fluorescent probe based on oligonucleotide-stabilized silver nanoclusters (DNA-AgNCs) was synthesized by employing a biotinylated cytosine-rich sequence as a synthesized template. The fluorescence properties of the DNA-AgNCs are related to the modified position of the DNA. When biotin is linked to the middle thymine base of the DNA sequence, the DNA-AgNCs emit the strongest fluorescence. Moreover, the stability of the DNA-AgNCs was affected by avidin through biotin-avidin binding, quenching the fluorescence of the DNA-AgNCs. In contrast, if free biotin is further introduced into this system, the quenching is apparently weakened by competition, leading to the restoration of fluorescence. This phenomenon can be utilized for the detection of biotin. Under the optimal conditions, the fluorescence recovery is linearly proportional to the concentration of biotin in the range of 10 nM-1.0 μM with a detection limit of 6.0 nM. This DNA-AgNCs probe with excellent fluorescent properties is sensitive and selective for the detection of biotin and has been applied for the determination of biotin in wheat flour.

  4. A capillary-based probe for in situ detection of enhanced fluorescence signals

    Science.gov (United States)

    Long, F.; Xiao, R.; Zhu, A. N.; Shi, H. C.; Wang, S. Q.

    2013-07-01

    A simple, compact, and high sensitivity capillary-based probe for the in situ detection of fluorescence signals with high sensitivity is demonstrated. A home-made single-multi-mode fiber coupler that is coaxially aligned with the capillary-based probe provides for the transmission of excitation light and the collection and transmission of fluorescence. We propose a conceptually straightforward theoretical model to optimize the factors affecting the fluorescence-capture capability of the capillary-based probe. The fluorescence signal detected by fiber-optic spectroscopy non-linearly increases with the length of the capillary-based probe. In addition, the thicker the capillary tube wall is, the less the fluorescence signals determined are. The performance of the proposed probe is evaluated experimentally by measuring the fluorescence spectra of Cy5.5 dye and blue-green algae. The experimental results show that the proposed probe provides more than a ten-fold increase in fluorescence signal compared with direct measurements by a flat-tipped multi-mode fiber probe. The advantages of the capillary-based probe, which include its simple and compact structure, excellent light collection efficiency, requirement of small sample volume, and recoverability of samples, allow its wide application to in situ detection in the medical, forensic, biological, geological, and environmental fields with high sensitivity.

  5. Metal-enhanced fluorescent detection for protein microarrays based on a silver plasmonic substrate.

    Science.gov (United States)

    Li, Hui; Wang, Min; Qiang, Weibing; Hu, Hongting; Li, Wei; Xu, Danke

    2014-04-07

    This paper presents an ultrasensitive fluorescent detection method through fabricating a silver microarray substrate. Silver nanoparticles (AgNPs) and Ag@Au core-shell nanoparticles with different sizes were first synthesized by a seed-mediated growth method and the metal-enhanced fluorescence of these nanoparticles on different fluorescent dyes was investigated. The results indicated that AgNPs could act as a versatile and effective metal-enhanced fluorescence material for various fluorophores, whereas the enhanced fluorescence from Ag@Au was limited only to certain fluorophores. When the AgNPs were functionalized with aptamers and fluorescent dyes, a good analytical performance for simultaneous detection of human IgE and platelet-derived growth factor-BB (PDGF-BB) could be obtained. AgNPs were not only used as detection tags but also used to fabricate the plasmonic microarray substrate to further enhance the sensitivity of fluorescent detection. As a result, a linear response to PDGF-BB concentration was obtained in the concentration range of 16 pg mL(-1) to 50 ng mL(-1), and the detection limit was 3.2 pg mL(-1). In addition, the AgNP modified plasmonic microarrays showed remarkable recovery and no significant interference from human serum when applied to 2 ng mL(-1) PDGF-BB concentration. The plasmonic microarray substrate demonstrated both high specificity and sensitivity for protein microarray detection and this novel approach has great potential for ultrasensitive detection of protein biomarkers in the bio-medical field.

  6. Enhancing early bladder cancer detection with fluorescence-guided endoscopic optical coherence tomography

    Science.gov (United States)

    Pan, Y. T.; Xie, T. Q.; Du, C. W.; Bastacky, S.; Meyers, S.; Zeidel, M. L.

    2003-12-01

    We report an experimental study of the possibility of enhancing early bladder cancer diagnosis with fluorescence-image-guided endoscopic optical coherence tomography (OCT). After the intravesical instillation of a 10% solution of 5-aminolevulinic acid, simultaneous fluorescence imaging (excitation of 380-420 nm, emission of 620-700 nm) and OCT are performed on rat bladders to identify the photochemical and morphological changes associated with uroepithelial tumorigenesis. The preliminary results of our ex vivo study reveal that both fluorescence and OCT can identify early uroepithelial cancers, and OCT can detect precancerous lesions (e.g., hyperplasia) that fluorescence may miss. This suggests that a cystoscope combining 5-aminolevulinic acid fluorescence and OCT imaging has the potential to enhance the efficiency and sensitivity of early bladder cancer diagnosis.

  7. Combining electrophoresis with detection under ultraviolet light and multiple ultrafiltration for isolation of humic fluorescence fractions.

    Science.gov (United States)

    Trubetskaya, Olga E; Shaloiko, Lubov A; Demin, Dmitrii V; Marchenkov, Victor V; Proskuryakov, Ivan I; Coelho, Christian; Trubetskoj, Oleg A

    2011-04-01

    Polyacrylamide gel electrophoresis of chernozem soil humic acids (HAs) followed by observation under UV (312 nm) excitation light reveals new low molecular weight (MW) fluorescent fractions. Ultrafiltration of HAs sample in 7 M urea on a membrane of low nominal MW retention (NMWR, 5 kDa) was repetitively used for separation of fluorescent and non-fluorescent species. Thirty ultrafiltrates and the final retentate R were obtained. Fluorescence maxima of separate ultrafiltrates were different and non-monotonously changed in the range of 475-505 nm. Fluorescence maxima of less than 490 nm were detected only in the four first utrafiltrates. For further physical-chemical analyses all utrafiltrates were combined into a fraction called UFchernozem soil HAs complex. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. A simple and compact fluorescence detection system for capillary electrophoresis and its application to food analysis.

    Science.gov (United States)

    Zhai, Haiyun; Yuan, Kaisong; Yu, Xiao; Chen, Zuanguang; Liu, Zhenping; Su, Zihao

    2015-10-01

    A novel fluorescence detection system for CE was described and evaluated. Two miniature laser pointers were used as the excitation source. A Y-style optical fiber was used to transmit the excitation light and a four-branch optical fiber was used to collect the fluorescence. The optical fiber and optical filter were imported into a photomultiplier tube without any extra fixing device. A simplified PDMS detection cell was designed with guide channels through which the optical fibers were easily aligned to the detection window of separation capillary. According to different requirements, laser pointers and different filters were selected by simple switching and replacement. The fluorescence from four different directions was collected at the same detecting point. Thus, the sensitivity was enhanced without peak broadening. The fluorescence detection system was simple, compact, low-cost, and highly sensitive, with its functionality demonstrated by the separation and determination of red dyes and fluorescent whitening agents. The detection limit of rhodamine 6G was 7.7 nM (S/N = 3). The system was further applied to determine illegal food dyes. The CE system is potentially eligible for food safety analysis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Silica Nanoparticle-Enhanced Fluorescent Sensor Array for Heavy Metal Ions Detection in Colloid Solution.

    Science.gov (United States)

    Peng, Juanjuan; Li, Junyao; Xu, Wang; Wang, Lu; Su, Dongdong; Teoh, Chai Lean; Chang, Young-Tae

    2018-02-06

    Sensitivity and detection limit are two vital factors that affect fluorophores-based sensing and imaging system. However, it remains a challenge to improve the sensitivity and detection limit of fluorophores, largely due to their limited response and photophysical properties. In this study, we report for the first time, a novel approach to enhance the sensitivity and detection limit of probes using silica nanoparticles, also known as silica nanoparticles-enhanced fluorescence (SiEF). SiEF can drastically improve the fluorescence intensities and detection limit of fluorophores. A SiEF-improved fluorescent sensor array for rapid and sensitive identification of different heavy metal ions is achieved, and a 3D spatial dispersion graph is obtained based on the SiEF-improved fluorescent sensor array, which provides a lower concentration dependent pattern than fluorophores alone, allowing qualitative, quantitative, and sensitive detection of heavy metal ions. Furthermore, with UV lamp irradiation of the sensor-metal ion mixtures, the output signals enable direct visual of heavy metal ions with low concentration. Thus, the SiEF approach provides a simple and practical strategy for fluorescent probes to improve their sensitivity and detection limit in analytes sensing.

  10. Fluorescent detection of C-reactive protein using polyamide beads

    Science.gov (United States)

    Jagadeesh, Shreesha; Chen, Lu; Aitchison, Stewart

    2016-03-01

    Bacterial infection causes Sepsis which is one of the leading cause of mortality in hospitals. This infection can be quantified from blood plasma using C - reactive protein (CRP). A quick diagnosis at the patient's location through Point-of- Care (POC) testing could give doctors the confidence to prescribe antibiotics. In this paper, the development and testing of a bead-based procedure for CRP quantification is described. The size of the beads enable them to be trapped in wells without the need for magnetic methods of immobilization. Large (1.5 mm diameter) Polyamide nylon beads were used as the substrate for capturing CRP from pure analyte samples. The beads captured CRP either directly through adsorption or indirectly by having specific capture antibodies on their surface. Both methods used fluorescent imaging techniques to quantify the protein. The amount of CRP needed to give a sufficient fluorescent signal through direct capture method was found suitable for identifying bacterial causes of infection. Similarly, viral infections could be quantified by the more sensitive indirect capture method. This bead-based assay can be potentially integrated as a disposable cartridge in a POC device due to its passive nature and the small quantities needed.

  11. Early detection of tumor masses by in vivo hematoporphyrin-mediated fluorescence imaging

    Energy Technology Data Exchange (ETDEWEB)

    Autiero, Maddalena [Dipartimento di Scienze Fisiche, Universita di Napoli Federico II, Via Cinthia, I-80126 Naples (Italy); Celentano, Luigi [Dipartimento di Scienze Biomorfologiche e Funzionali, Universita di Napoli Federico II, Via Pansini 5, I-80126 Naples (Italy); Cozzolino, Rosanna [Dipartimento di Biologia Strutturale e Funzionale, Universita di Napoli Federico II, Via Cinthia, I-80126 Naples (Italy); Laccetti, Paolo [Dipartimento di Biologia Strutturale e Funzionale, Universita di Napoli Federico II, Via Cinthia, I-80126 Naples (Italy); Marotta, Marcello [Dipartimento di Medicina Clinica e Sperimentale, Universita di Napoli Federico II, Via Pansini 5, I-80131 Naples (Italy); Mettivier, Giovanni [Dipartimento di Scienze Fisiche, Universita di Napoli Federico II, Via Cinthia, I-80126 Naples (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Via Cinthia, I-80126 Naples (Italy); Cristina Montesi, Maria [Dipartimento di Scienze Fisiche, Universita di Napoli Federico II, Via Cinthia, I-80126 Naples (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Via Cinthia, I-80126 Naples (Italy); Quarto, Maria [Dipartimento di Scienze Fisiche, Universita di Napoli Federico II, Via Cinthia, I-80126 Naples (Italy); Riccio, Patrizia [Dipartimento di Biologia e Patologia Cellulare e Molecolare, Universita di Napoli Federico II, Via Pansini 5, I-80131 Naples (Italy); Roberti, Giuseppe [Dipartimento di Scienze Fisiche, Universita di Napoli Federico II, Via Cinthia, I-80126 Naples (Italy)]. E-mail: roberti@unina.it; Russo, Paolo [Dipartimento di Scienze Fisiche, Universita di Napoli Federico II, Via Cinthia, I-80126 Naples (Italy); Istituto Nazionale di Fisica Nucleare (INFN), Via Cinthia, I-80126 Naples (Italy)

    2007-02-01

    We investigated the capability of fluorescence reflectance imaging (FRI) for the early detection of surface tumors in mice. We used a hematoporphyrin (HP) compound (HP dichlorohydrate) as a red fluorescent marker and a low noise, high sensitivity, digital CCD camera for fluorescence imaging. In this preliminary study, highly malignant anaplastic human thyroid carcinoma cells were implanted subcutaneously in one mouse and their growth was monitored daily for 5 days by FRI. The selective HP uptake by the tumor tissues was successfully observed: we observed the fluorescence of tumor only 3 days after cancer cells injection, i.e. when the tumor mass was neither visible (to the naked eye) or palpable. These measurements indicate that FRI is a suitable technique to detect minute subcutaneous tumor masses. This FRI system will be coupled to a radionuclide imaging system based on a CdTe detector for in vivo multimodal imaging in mice.

  12. Early detection of tumor masses by in vivo hematoporphyrin-mediated fluorescence imaging

    International Nuclear Information System (INIS)

    Autiero, Maddalena; Celentano, Luigi; Cozzolino, Rosanna; Laccetti, Paolo; Marotta, Marcello; Mettivier, Giovanni; Cristina Montesi, Maria; Quarto, Maria; Riccio, Patrizia; Roberti, Giuseppe; Russo, Paolo

    2007-01-01

    We investigated the capability of fluorescence reflectance imaging (FRI) for the early detection of surface tumors in mice. We used a hematoporphyrin (HP) compound (HP dichlorohydrate) as a red fluorescent marker and a low noise, high sensitivity, digital CCD camera for fluorescence imaging. In this preliminary study, highly malignant anaplastic human thyroid carcinoma cells were implanted subcutaneously in one mouse and their growth was monitored daily for 5 days by FRI. The selective HP uptake by the tumor tissues was successfully observed: we observed the fluorescence of tumor only 3 days after cancer cells injection, i.e. when the tumor mass was neither visible (to the naked eye) or palpable. These measurements indicate that FRI is a suitable technique to detect minute subcutaneous tumor masses. This FRI system will be coupled to a radionuclide imaging system based on a CdTe detector for in vivo multimodal imaging in mice

  13. A Fluorescence Polarization Assay To Detect Steroid Hormone Traces in Milk.

    Science.gov (United States)

    Varriale, Antonio; Pennacchio, Anna; Pinto, Gabriella; Oliviero, Giorgia; D'Errico, Stefano; Majoli, Adelia; Scala, Andrea; Capo, Alessandro; Pennacchio, Angela; Di Giovanni, Stefano; Staiano, Maria; D'Auria, Sabato

    2015-10-21

    Steroids are a class of hormones improperly used in livestock as growth-promoting agents. Due to their high risk for human health, the European Union (EU) has strictly forbidden the administration of all natural and synthetic steroid hormones to food-producing animals, and the development of new rapid detection methods are greatly encouraged. This work reports a novel fluorescence polarization assay, ready to use, capable of detecting 17β-estradiol directly in milk samples with a low limit of detection of <10 pmol. It is based on the coupling of monospecific antibodies against 17β-estradiol and fluorophores, capable of modulating the fluorescence polarization emission on the basis of the specific binding of antibodies to fluorescence-labeled 17β-estradiol derivative. The successful detection of 17β-estradiol has disclosed the development of an efficient method, easily extensible to any food matrix and having the potential to become a milestone in food quality and safety.

  14. Arsenic speciation in natural water samples by coprecipitation-hydride generation atomic absorption spectrometry combination.

    Science.gov (United States)

    Tuzen, Mustafa; Citak, Demirhan; Mendil, Durali; Soylak, Mustafa

    2009-04-15

    A speciation procedure for As(III) and As(V) ions in environmental samples has been presented. As(V) was quantitatively recovered on aluminum hydroxide precipitate. After oxidation of As(III) by using dilute KMnO(4), the developed coprecipitation was applied to determination of total arsenic. Arsenic(III) was calculated as the difference between the total arsenic content and As(V) content. The determination of arsenic levels was performed by hydride generation atomic absorption spectrometry (HG-AAS). The analytical conditions for the quantitative recoveries of As(V) including pH, amount of aluminum as carrier element and sample volume, etc. on the presented coprecipitation system were investigated. The effects of some alkaline, earth alkaline, metal ions and also some anions were also examined. Preconcentration factor was calculated as 25. The detection limits (LOD) based on three times sigma of the blank (N: 21) for As(V) was 0.012 microg L(-1). The satisfactory results for the analysis of arsenic in NIST SRM 2711 Montana soil and LGC 6010 Hard drinking water certified reference materials for the validation of the method was obtained. The presented procedure was successfully applied to real samples including natural waters for arsenic speciation.

  15. Fluorescence hyperspectral imaging technique for the foreign substance detection on fresh-cut lettuce

    Science.gov (United States)

    Nondestructive methods based on fluorescence hyperspectral imaging (HSI) techniques were developed in order to detect worms on fresh-cut lettuce. The optimal wavebands for detecting worms on fresh-cut lettuce were investigated using the one-way ANOVA analysis and correlation analysis. The worm detec...

  16. Determination of acetylsalicylic acid and salicylic acid in foods, using HPLC with fluorescence detection.

    NARCIS (Netherlands)

    Venema, D.P.; Hollman, P.C.H.; Janssen, P.L.T.M.K.; Katan, M.B.

    1996-01-01

    We developed a specific and sensitive HPLC method with fluorescence detection for the determination of free acetylsalicylic acid, free salicylic acid, and free salicylic acid plus salicylic acid after alkaline hydrolysis (free-plus-bound) in foods. Acetylsalicylic acid was detected after postcolumn

  17. Capillary electrophoresis with laser-induced fluorescence detection for fast and reliable apolipoprotein E genotyping

    NARCIS (Netherlands)

    Somsen, GW; Welten, HTME; Mulder, FP; Swart, CW; Kema, IP; de Jong, GJ

    2002-01-01

    The use of capillary electrophoresis (CE) with laser-induced fluorescence (LIF) detection for the rapid determination of apolipoprotein E (apoE) genotypes was studied. High resolution and sensitive detection of the concerned DNA restriction fragments was achieved using CE buffers with

  18. Detection of Resistance to Macrolides in Thermotolerant Campylobacter Species by Fluorescence In Situ Hybridization▿

    OpenAIRE

    Haas, Michaela; Essig, Andreas; Bartelt, Edda; Poppert, Sven

    2008-01-01

    The resistance of enteritis-causing Campylobacter strains to erythromycin is an emerging problem. We therefore evaluated fluorescence in situ hybridization (FISH) for the rapid detection of resistance using 74 campylobacter isolates. FISH showed specificity and sensitivity of 100% for the detection of high-level resistance.

  19. Sensitive detection and separation of fluorescent derivatives using capillary electrophoresis with laser-induced fluorescence detection with 532nm Nd:YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Vrabel, Patrik [Department of Analytical Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic); Taborsky, Petr [Department of Analytical Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic); Ryvolova, Marketa [Department of Analytical Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic); Havel, Josef [Department of Analytical Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic); Preisler, Jan [Department of Analytical Chemistry, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic)]. E-mail: preisler@chemi.muni.cz

    2006-06-15

    Capillary electrophoresis with laser-induced fluorescence detection (CELIF) is a powerful tool for separation and sensitive determination of fluorescent species. Biologically active compounds, such as amino acids, peptides and proteins may exhibit native fluorescence, which is however often low and/or an expensive laser is required for excitation in UV. Therefore, labelling of the analytes with a fluorescent dye is usually necessary. In this work, a home-built CELIF instrument with diode pumped frequency-doubled continuous wave Nd:YAG excitation laser with feedback power regulation (532nm) was constructed. The suitability of this type of laser for LIF detection in a separation method was found excellent. A limit of detection (LOD) (S/N=3) of 2x10{sup -13}mol/l was achieved with rhodamine B, which is comparable to those obtained using similar instruments with Ar{sup +} laser [Y.F. Cheng, N.J. Dovichi, Science 242 (1988) 562, E.S. Yeung et al., J. Chromatogr. 608 (1992) 73]. LOD of a protein derivatized according to modified procedures [M.J. Little et al., Anal. Chim. Acta 339 (1997) 279, A. Chersi et al., Biochim. Biophys. Acta 1336 (1997) 83] was determined. Detection of the derivatives was found to be limited by insufficient reaction recovery at low analyte concentration, chemical noise, separation efficiency and quality of the derivatizing reagent rather than by the detector performance. As a consequence, a huge gap between the detection ability of CELIF instruments and LOD determined in real samples is revealed.

  20. Use of a Novel Rover-mounted Fluorescence Imager and Fluorescent Probes to Detect Biological Material in the Atacama Desert in Daylight

    Science.gov (United States)

    Weinstein, S.; Pane, D.; Warren-Rhodes, K.; Cockell, C.; Ernst, L. A.; Minkley, E.; Fisher, G.; Emani, S.; Wettergreen, D. S.; Wagner, M.

    2005-01-01

    We have developed an imaging system, the Fluorescence Imager (FI), for detecting fluorescence signals from sparse microorganisms and biofilms during autonomous rover exploration. The fluorescence signals arise both from naturally occurring chromophores, such as chlorophyll of cyanobacteria and lichens, and from fluorescent probes applied to soil and rocks. Daylight imaging has been accomplished by a novel use of a high-powered flashlamp synchronized to a CCD camera. The fluorescent probes are cell permanent stains that have extremely low intrinsic fluorescence (quantum yields less than 0.01) and a large fluorescence enhancement (quantum yields greater than 0.4) when bound to the target. Each probe specifically targets either carbohydrates, proteins, nucleic acids or membrane lipids, the four classes of macromolecules found in terrestrial life. The intent of the probes is to interrogate the environment for surface and endolithic life forms.

  1. Highly selective fluorescent probe for the detection of tin (IV) Ion

    International Nuclear Information System (INIS)

    Zhu, Leiming; Yang, Jing; Wang, Qiusheng; Zeng, Lintao

    2014-01-01

    A novel fluorescent compound, 7-diethylamino-3-(2'-(1H-imidazo[4,5-b]phenazine)yl)coumarin (DIPC), was synthesized and employed as a fluorescent probe for detecting tin (IV) ion. Upon addition of tin (IV) ion to the solution of DIPC in DMSO–water (9:1, v/v), DIPC exhibited a considerable red-shift in its absorption spectrum and a decrease in fluorescence intensity. These changes result from tin (IV) ion binding to carbonyl oxygen of coumarin and nitrogen of imidazole, reflecting an enhanced ICT process from N,N-diethylamino unit to imidazole unit. The tin (IV) ion selective response was clearly observed by the naked eye through color change. We also studied the bioimaging application of DIPC for detecting tin (IV) ion in Hela cells. And a significant decrease of the fluorescence from the intracellular area was observed. -- Highlights: • We synthesized a novel coumarin derivative (DIPC). • DIPC was used to detect tin (IV) ion selectively. • The detection process was studied upon UV–vis and fluorescence spectrum. • We studied the bioimaging application of DIPC for detecting Sn 4+ ion in cells

  2. Visual and fluorescent detection of acetamiprid based on the inner filter effect of gold nanoparticles on ratiometric fluorescence quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Xu [Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012 (China); Li, Hongxia [School of Pharmacy, Jilin University, Changchun 130021 (China); Li, Yang [Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012 (China); Su, Xingguang, E-mail: suxg@jlu.edu.cn [Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012 (China)

    2014-12-10

    Highlights: • The RF-QDs were fabricated by two different QDs using layer-by-layer assembly methods. • The PL intensity of RF-QDs could be quenched by AuNPs based on inner-filter effect. • Acetamiprid can adsorb on AuNPs led to the PL intensity of RF-QDs recover properly. • AuNPs serve a dual function as fluorescence quencher and colorimetric reporter in the sensor. - Abstract: In this work, we develop a simple and rapid sensing method for the visual and fluorescent detection of acetamiprid (AC) based on the inner-filter effect (IFE) of gold nanoparticles (AuNPs) on ratiometric fluorescent quantum dots (RF-QDs). The RF-QDs based dual-emission nanosensor was fabricated by assembling green emissive QDs (QDs{sub 539} {sub nm}, λ{sub em} = 539 nm) on the surface of red emissive QDs (QDs{sub 661} {sub nm}, λ{sub em} = 661 nm)-doped silica microspheres. The photoluminescence (PL) intensity of RF-QDs could be quenched by AuNPs based on IFE. Acetamiprid can adsorb on the surface of AuNPs due to its cyano group that has good affinity with gold, which could induce the aggregation of AuNPs accompanying color change from red to blue. Thus, the IFE of AuNPs on RF-QDs was weakened and the PL intensity of RF-QDs was recovered accordingly. Under the optimized conditions, the PL intensity of the RF-QDs/AuNPs system was proportional to the concentration of AC in the range of 0.025–5.0 μg mL{sup −1}, with a detection limit of 16.8 μg L{sup −1}. The established method had been used for AC detection in environmental and agricultural samples with satisfactory results.

  3. Fluorescence spectra of blood and urine for cervical cancer detection

    Science.gov (United States)

    Masilamani, Vadivel; AlSalhi, Mohamad Saleh; Vijmasi, Trinka; Govindarajan, Kanaganaj; Rathan Rai, Ram; Atif, Muhammad; Prasad, Saradh; Aldwayyan, Abdullah S.

    2012-09-01

    In the current study, the fluorescence emission spectra (FES) and Stokes shift spectra (SSS) of blood and urine samples of cervical cancer patients were obtained and compared to those of normal controls. Both spectra showed that the relative intensity of biomolecules such as porphyrin, collagen, Nicotinamide adenine dinucleotide, and flavin were quite out of proportion in cervical cancer patients. The biochemical mechanism for the elevation of these fluorophores is not yet definitive; nevertheless, these biomolecules could serve as tumor markers for diagnosis, screening, and follow-up of cervical cancers. To the best of our knowledge, this is the first report on FES and SSS of blood and urine of cervical cancer patients to give a sensitivity of 80% and specificity of 78%.

  4. Molecular Detection of Bladder Cancer by Fluorescence Microsatellite Analysis and an Automated Genetic Analyzing System

    Directory of Open Access Journals (Sweden)

    Sarel Halachmi

    2007-01-01

    Full Text Available To investigate the ability of an automated fluorescent analyzing system to detect microsatellite alterations, in patients with bladder cancer. We investigated 11 with pathology proven bladder Transitional Cell Carcinoma (TCC for microsatellite alterations in blood, urine, and tumor biopsies. DNA was prepared by standard methods from blood, urine and resected tumor specimens, and was used for microsatellite analysis. After the primers were fluorescent labeled, amplification of the DNA was performed with PCR. The PCR products were placed into the automated genetic analyser (ABI Prism 310, Perkin Elmer, USA and were subjected to fluorescent scanning with argon ion laser beams. The fluorescent signal intensity measured by the genetic analyzer measured the product size in terms of base pairs. We found loss of heterozygocity (LOH or microsatellite alterations (a loss or gain of nucleotides, which alter the original normal locus size in all the patients by using fluorescent microsatellite analysis and an automated analyzing system. In each case the genetic changes found in urine samples were identical to those found in the resected tumor sample. The studies demonstrated the ability to detect bladder tumor non-invasively by fluorescent microsatellite analysis of urine samples. Our study supports the worldwide trend for the search of non-invasive methods to detect bladder cancer. We have overcome major obstacles that prevented the clinical use of an experimental system. With our new tested system microsatellite analysis can be done cheaper, faster, easier and with higher scientific accuracy.

  5. Fluorescence ELISA for sensitive detection of ochratoxin A based on glucose oxidase-mediated fluorescence quenching of CdTe QDs

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Yi [State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Jiangxi-OAI Joint Research Institute, Nanchang University, Nanchang 330047 (China); Huang, Xiaolin [State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Yu, Ruijin [College of Science, Northwest A& F University, Yangling, Shaanxi 712100 (China); Zhou, Yaofeng [State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Xiong, Yonghua, E-mail: yhxiongchen@163.com [State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047 (China); Jiangxi-OAI Joint Research Institute, Nanchang University, Nanchang 330047 (China)

    2016-09-14

    The present study described a novel fluorescence enzyme-linked immunosorbent assay (ELISA) used to detect ochratoxin A (OTA) by using the glucose oxidase (GOx)-mediated fluorescence quenching of mercaptopropionic acid-capped CdTe quantum dots (MPA-QDs), in which GOx was used as an alternative to horseradish peroxidase (HRP) for the oxidization of glucose into hydrogen peroxide (H{sub 2}O{sub 2}) and gluconic acid. The MPA-QDs were used as a fluorescent signal output, whose fluorescence variation was extremely sensitive to the presence of H{sub 2}O{sub 2} or hydrogen ions in the solution. Under the optimized conditions, the proposed fluorescence ELISA demonstrated a good linear detection of OTA in corn extract from 2.4 pg mL{sup −1} to 625 pg mL{sup −1} with a limit of detection of 2.2 pg mL{sup −1}, which was approximately 15-fold lower than that of conventional HRP-based ELISA. Our developed fluorescence immunoassay was also similar to HRP-based ELISA in terms of selectivity, accuracy, and reproducibility. In summary, this study was the first to use the GOx-mediated fluorescence quenching of QDs in immunoassay to detect OTA, offering a new possibility for the analysis of other mycotoxins and biomolecules. - Highlights: • A novel fluorescence ELISA was first developed for the detection of OTA by using GOx-mediated fluorescence quenching of QDs. • The pH- and H{sub 2}O{sub 2}-sensitive MPA-capped CdTe QDs were used as a fluorescent signal output to improve the detection sensitivity. • This novel method open up a different vision to detect other mycotoxins and biomolecules.

  6. Detection of bacterial infection of agave plants by laser-induced fluorescence

    Science.gov (United States)

    Cervantes-Martinez, Jesus; Flores-Hernandez, Ricardo; Rodriguez-Garay, Benjamin; Santacruz-Ruvalcaba, Fernando

    2002-05-01

    Greenhouse-grown plants of Agave tequilana Weber var. azul were inoculated with Erwinia carotovora, the causal agent of stem soft rot. We investigated the laser-induced fluorescence (LIF) of agave plants to determine whether LIF can be used as a noninvasive sensing tool for pathological studies. The LIF technique was also investigated as a means of detecting the effect of the polyamine biosynthesis inhibitor beta-hydroxyethylhydrazine as a bactericide against the pathogenic bacterium Erwinia carotovora. A He-Ne laser at 632.8 nm was used as the excitation source, and in vivo fluorescence emission spectra were recorded in the 660-790-range. Fluorescence maxima were at 690 and 740 nm. The infected plants that were untreated with the bactericide showed a definite increase in fluorescence intensity at both maxima within the first three days after infection. Beginning on the fifth day, a steady decrease in fluorescence intensity was observed, with a greater effect at 740 than at 690 nm. After 30 days there was no fluorescence. The infected plants that had been treated with the bactericide showed no significant change in fluorescence compared with that of the uninfected plants. The ratio of fluorescence intensities was determined to be F 690 nm/F 740 nm for all treatments. These studies indicate that LIF measurements of agave plants may be used for the early detection of certain types of disease and for determining the effect of a bactericide on bacteria. The results also showed that fluorescence intensity ratios can be used as a reliable indicator of the progress of disease.

  7. Electrochemical hydride generation atomic absorption spectrometry for determination of cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Arbab-Zavar, M.H. [Department of Chemistry, Faculty of Science, Ferdowsi University, Mashhad (Iran, Islamic Republic of)]. E-mail: arbab@um.ac.ir; Chamsaz, M. [Department of Chemistry, Faculty of Science, Ferdowsi University, Mashhad (Iran, Islamic Republic of); Youssefi, A. [Pare-Taavous Research Institute, Mashhad (Iran, Islamic Republic of); Aliakbari, M. [Department of Chemistry, Faculty of Science, Ferdowsi University, Mashhad (Iran, Islamic Republic of)

    2005-08-01

    An electrolytic hydride generation system for determination of another hydride forming element, cadmium, by catholyte variation electrochemical hydride generation (EcHG) atomic absorption spectrometry is described. A laboratory-made electrolytic cell with lead-tin alloy as cathode material is designed as electrolytic generator of molecular hydride. The influences of several parameters on the analytical signal have been evaluated using a Plackett-Burman experimental design. The significant parameters such as cathode surface area, electrolytic current, carrier gas flow rate and catholyte concentration have been optimized using univariate method. The analytical figures of merit of procedure developed were determined. The calibration curve was linear up to 20 ng ml{sup -1}of cadmium. The concentration detection limit (3{sigma}, n = 8) of 0.2 ng ml{sup -1} and repeatability (relative standard deviation, n = 7) of 3.1% were achieved at 10.0 ng ml{sup -1}. It was shown that interferences from major constituents at high concentrations were significant. The accuracy of method was verified using a real sample (spiked tap water) by standard addition calibration technique. Recovery of 104% was achieved for Cd in the spiked tap water sample.

  8. Enzyme-Free Detection of Mutations in Cancer DNA Using Synthetic Oligonucleotide Probes and Fluorescence Microscopy

    DEFF Research Database (Denmark)

    Miotke, Laura; Maity, Arindam; Ji, Hanlee

    2015-01-01

    BACKGROUND: Rapid reliable diagnostics of DNA mutations are highly desirable in research and clinical assays. Current development in this field goes simultaneously in two directions: 1) high-throughput methods, and 2) portable assays. Non-enzymatic approaches are attractive for both types......) and finally, detection by fluorescence microscopy. The LNA containing probes display high binding affinity and specificity to DNA containing mutations, which allows for the detection of mutation abundance with an intercalating EvaGreen dye. We used a second probe, which increases the overall number of base...... pairs in order to produce a higher fluorescence signal by incorporating more dye molecules. Indeed we show here that using EvaGreen dye and LNA probes, genomic DNA containing BRAF V600E mutation could be detected by fluorescence microscopy at low femtomolar concentrations. Notably, this was at least...

  9. Thickness dependence of polydopamine thin films on detection sensitivity of surface plasmon-enhanced fluorescence biosensors

    Science.gov (United States)

    Toma, Mana; Tawa, Keiko

    2018-03-01

    A bioinspired polydopamine (PDA) coating is a good candidate for the rapid and cheap chemical modification of biosensor surfaces. Herein, we report the effect of PDA thickness on the detection sensitivity of a fluorescence biosensor utilizing surface plasmon-enhanced fluorescence. The thickness of PDA films was tuned by the incubation time of the dopamine solution and varied from 1 to 17 nm. The detection sensitivity was evaluated as the limit of detection (LOD) of a fluorescently labelled target analyte by a model immunoassay. The LOD was determined to be 1.6 pM for the thickest PDA film and was improved to 1.0 pM by reducing the thickness to the range from 1 to 5 nm, corresponding to the incubation time of 10 to 60 min. The experimental results indicate that the PDA coating is suitable for the surface functionalization of biosensors in mass production as it does not require precise control of the incubation time.

  10. Terbium Functionalized Micelle Nanoprobe for Ratiometric Fluorescence Detection of Anthrax Spore Biomarker.

    Science.gov (United States)

    Luan, Ke; Meng, Ruiqian; Shan, Changfu; Cao, Jing; Jia, Jianguo; Liu, Weisheng; Tang, Yu

    2018-03-06

    Rapid, sensitive, and selective quantitative detection of pyridine dicarboxylic acid (DPA) as biomarker of anthrax spores is in great demand since anthrax spores are highly lethal to human beings and animals and also potential biological warfare agents. Herein, we prepared a ratiometric fluorescence lanthanide functionalized micelle nanoprobe by "one-pot" self-assembly, with an amphiphilic ligand containing β-diketone derivative which can "immobilize" terbium ions through the coordination interaction and a fluorophore as fluorescence reference (FR). The detection strategy was ascribed to Tb 3+ ions in lanthanide functionalized micelle, which can be sensitized to emit the intrinsic luminescence upon addition of DPA due to the presence of energy transfer when DPA chromophore coordinated with Tb 3+ ion. The fluorescence intensity of FR remained essentially constant, leading to ratiometric fluorescence response toward DPA. The results demonstrate that the terbium functionalized micelle was able to sensitively detect DPA with a linear relation in the range of 0 μM to 7.0 μM in aqueous solution, which also showed remarkable selectivity to DPA over other aromatic ligands. Our work paves a new way in the design of ratiometric fluorescence lanthanide functionalized micelle nanoprobes which can be promising for selective and sensitive detection of bacterial spores or biomolecules.

  11. Two sugar-rhodamine "turn-on" fluorescent probes for the selective detection of Fe3 +

    Science.gov (United States)

    Chen, Qing; Fang, Zhijie

    2018-03-01

    Two new sugar-rhodamine fluorescent probes (RDG1 and RDG2) have been synthesized and characterized by 1H NMR, 13C NMR and HRMS. Their UV-Vis, fluorescence spectra and fluorescence-response to Fe3 + are investigated and discussed. RDG1 had a very nice linear relationship between UV absorbance and Fe3 + concentration with the correlation coefficient as high as 0.997 and the detection limit is 3.46 × 10- 6 M. Upon the addition of Fe3 +, the spirolactam ring of RDG1 was opened and a 1:1 metal ligand complex was formed from Job's plot. The results showed that RDG1 can be used as an effective fluorescent probe for selective detection of Fe3 + in water. RDG2 was incorporated the well-known rhodamine group and a water-soluble D-glucose group within one molecule and can be used for detecting Fe3 + in natural water as a selective fluorescent sensor. The addition of Fe3 + into RDG2 resulted in a strongly enhanced fluorescence as well as color change of solution from colorless to pink. Job's plot of RDG2 indicated 1:1 stoichiometry of RDG2-Fe3 +. RDG2 can serve as a probe for Fe3 + between pH = 4.0 to 7.0 and it's detection limit is 2.09 × 10- 6 M. The OFF-ON fluorescent mechanisms of RDG1-Fe3 + and RDG2-Fe3 + are proposed.

  12. Detection of early interproximal caries in vitro using laser fluorescence, dye-enhanced laser fluorescence and direct visual examination.

    Science.gov (United States)

    Eggertsson, H; Analoui, M; van der Veen, M; González-Cabezas, C; Eckert, G; Stookey, G

    1999-01-01

    This in vitro study evaluated the use of laser fluorescence (LF) for the detection of early interproximal carious lesions and whether the detection could be enhanced using a fluorescent dye (DELF). Direct visual examination (DV) was used for comparison. Eighty extracted teeth were used, arranged in 20 blocks, each block having 2 premolars and 2 molars, lined up in a simulated sextant situation. After cleaning with a microabrasion kit, a subcontact window on half of the surfaces (60) was exposed to Carbopol white-spot solution for 5 days. The teeth were remounted in stone and examined by three independent examiners. For LF and DELF an argon laser was used (mixed wavelength of 488 and 514 nm) viewed through glasses (excluding wavelength stained with rhodamine B, and images were taken using a confocal microscope. The images were analyzed using a histogram program for lesion depth and image area. Lesions were present in 62 out of 120 approximal surfaces, with an average depth of 60 microm (range 17-190 microm). Sensitivity ranges for LF, DELF and DV were 56-74, 61-79 and 58-74%, and specificity ranges 67-78, 86-98 and 83-97%, respectively. With this model DELF compared favorably with DV and LF in sensitivity, but specificity was better for DELF and DV than for LF.

  13. Detecting river pollution using fluorescence spectrophotometry: case studies from the Ouseburn, NE England

    International Nuclear Information System (INIS)

    Baker, Andy; Inverarity, Roger; Charlton, Martin; Richmond, Susie

    2003-01-01

    Fluorescence spectrophotometry can be used to detect sewage pollution in an urban river. - Recent advances in fluorescence spectrophotometry enable the analysis of river dissolved organic matter. We investigate the potential of detecting sewage pollution in a small, urbanised catchment. Downstream sampling highlighted a summer maximum in tryptophan fluorescence intensity during low flow. No correlation is observed between ammonia and tryptophan fluorescence intensity. In contrast, two sewage related point-pollution events had both high tryptophan fluorescence intensity and ammonia, suggesting that the summer tryptophan increase does not original from foul sewage. Sewage inputs to the river were therefore monitored at summer baseflow. This demonstrated that >10% of the rivers' discharge is provided by sewerage inputs and that these inputs could be grouped by their fluorescence and ammonia properties: (1) 'clean' storm waters with low ammonia and tryptophan intensity (2) 'grey' waters with high tryptophan intensity and low ammonia concentration, and (3) 'foul' waters with high tryptophan intensity and ammonia concentration. All three types of sewerage input occurred irrespective of flow conditions, suggesting that sewerage cross connections are occurring

  14. Fluorescent Silica Nanoparticles in the Detection and Control of the Growth of Pathogen

    International Nuclear Information System (INIS)

    Chitra, K.; Annadurai, G.

    2013-01-01

    In this present study the bio conjugated fluorescent silica nanoparticles give an efficient fluorescent-based immunoassay for the detection of pathogen. The synthesized silica nanoparticles were poly dispersed and the size of the silica nanoparticles was in the range of 114-164 nm. The energy dispersive X-ray spectrophotometer showed the presence of silica at 1.8 keV and the selected area diffractometer showed amorphous nature of silica nanoparticles. The FTIR spectrum confirmed the attachment of dye and carboxyl group onto the silica nanoparticles surface. The fluorescent silica nanoparticles showed highly efficient fluorescence and the fluorescent emission of silica nanoparticles occurred at 536 nm. The SEM image showed the aggregation of nanoparticles and bacteria. The growth of the pathogenic E. coli was controlled using silica nanoparticles; therefore silica nanoparticles could be used in food packaging material, biomedical material, and so forth. This work provides a rapid, simple, and accurate method for the detection of pathogen using fluorescent-based immunoassay.

  15. New approach to breast tumor detection based on fluorescence x-ray analysis

    Directory of Open Access Journals (Sweden)

    Okuyama, Fumio

    2010-01-01

    Full Text Available A new technical approach to breast-tumor detection is proposed. The technique is based on fluorescence x-ray analysis, and can identify a miniature malignant tumor within the breast. The primary beam intensity needed in fluorescence x-ray analysis is on a lower order of magnitude than that used in mammography. Thus, the newly-proposed technique would enable detection of a still tiny breast cancer while dramatically lowering the radiation dose. Field-emission x-ray sources might be a key for translating this concept into a medical technique.

  16. Rapid and sensitive detection of clenbuterol using a fluorescence nanosensor based on diazo coupling mechanism

    Science.gov (United States)

    Thanh Hop Tran, Thi; Huong Do, Thi Mai; Hoang, Mai Ha; Tuyen Nguyen, Duc; Le, Quang Tuan; Nghia Nguyen, Duc; Ngo, Trinh Tung

    2015-01-01

    In this paper, the fluorescence resonance energy transfer (FRET) effect has been used for fabrication of nanosensor for the detection of clenbuterol. In the nanosensor, the CdTe quantum dots (QDs) are the donors while the acceptor is the super-macromolecule formed by the diazoation coupling mechanism between diazo clenbuterol and naphthylethylene diamine. Changes in fluorescence intensities of nanosensor were used to determine the clenbuterol concentration. We have successfully fabricated a nanosensor for detection of clenbuterol sensible to clenbuterol concentration of 10-12 g ml-1.

  17. Method for detecting binding events using micro-X-ray fluorescence spectrometry

    Science.gov (United States)

    Warner, Benjamin P.; Havrilla, George J.; Mann, Grace

    2010-12-28

    Method for detecting binding events using micro-X-ray fluorescence spectrometry. Receptors are exposed to at least one potential binder and arrayed on a substrate support. Each member of the array is exposed to X-ray radiation. The magnitude of a detectable X-ray fluorescence signal for at least one element can be used to determine whether a binding event between a binder and a receptor has occurred, and can provide information related to the extent of binding between the binder and receptor.

  18. A simple and sensitive fluorescent probe for specific detection of ...

    Indian Academy of Sciences (India)

    Yan-Fei Kang

    ety of human diseases like neurotoxicity, skin lesions, edema, muscle weakness, lethargy, slow growth, hair ... fore, the probe 1 could selectively detect Cys level. In order to explore the effects of other analytes for ... 1 for Cys did not change clearly in the presence of other amino acids or metal ions, even Hcy and GSH.

  19. A simple and sensitive fluorescent probe for specific detection of ...

    Indian Academy of Sciences (India)

    Yan-Fei Kang

    depigmentation,3 cardiovascular4 and Alzheimer's dis- eases.5 Similarly, glutathione (GSH) is the most abun- dant intracellular non-protein thiol and is considered to be an indicator of oxidative stress.6,7 As a conse- quence, detection of these low molecular weight thiols is important and timely. Therefore, a great many of.

  20. Prenatal detection of aneuploidies using fluorescence in situ ...

    Indian Academy of Sciences (India)

    Unknown

    spreads and reduces the time of reporting. However, with the limited number of probes used, the ... The singular benefit of FISH is the rapid detection of aneuploidy by chromosome specific probes applied to ..... racy, was integrated in a clinical prenatal diagnosis program. The assay confirmed the cytogenetic findings, for the.

  1. ISS Ammonia Leak Detection Through X-Ray Fluorescence

    Science.gov (United States)

    Camp, Jordan; Barthelmy, Scott; Skinner, Gerry

    2013-01-01

    Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge

  2. Tools for the quantitative analysis of sedimentation boundaries detected by fluorescence optical analytical ultracentrifugation.

    Directory of Open Access Journals (Sweden)

    Huaying Zhao

    Full Text Available Fluorescence optical detection in sedimentation velocity analytical ultracentrifugation allows the study of macromolecules at nanomolar concentrations and below. This has significant promise, for example, for the study of systems of high-affinity protein interactions. Here we describe adaptations of the direct boundary modeling analysis approach implemented in the software SEDFIT that were developed to accommodate unique characteristics of the confocal fluorescence detection system. These include spatial gradients of signal intensity due to scanner movements out of the plane of rotation, temporal intensity drifts due to instability of the laser and fluorophores, and masking of the finite excitation and detection cone by the sample holder. In an extensive series of experiments with enhanced green fluorescent protein ranging from low nanomolar to low micromolar concentrations, we show that the experimental data provide sufficient information to determine the parameters required for first-order approximation of the impact of these effects on the recorded data. Systematic deviations of fluorescence optical sedimentation velocity data analyzed using conventional sedimentation models developed for absorbance and interference optics are largely removed after these adaptations, resulting in excellent fits that highlight the high precision of fluorescence sedimentation velocity data, thus allowing a more detailed quantitative interpretation of the signal boundaries that is otherwise not possible for this system.

  3. Detection of DNA hybridization based on SnO2 nanomaterial enhanced fluorescence

    International Nuclear Information System (INIS)

    Gu Cuiping; Huang Jiarui; Ni Ning; Li Minqiang; Liu Jinhuai

    2008-01-01

    In this paper, enhanced fluorescence emissions were firstly investigated based on SnO 2 nanomaterial, and its application in the detection of DNA hybridization was also demonstrated. The microarray of SnO 2 nanomaterial was fabricated by the vapour phase transport method catalyzed by patterned Au nanoparticles on a silicon substrate. A probe DNA was immobilized on the substrate with patterned SnO 2 nanomaterial, respectively, by covalent and non-covalent linking schemes. When a fluorophore labelled target DNA was hybridized with a probe DNA on the substrate, fluorescence emissions were only observed on the surface of SnO 2 nanomaterial, which indicated the property of enhancing fluorescence signals from the SnO 2 nanomaterial. By comparing the different fluorescence images from covalent and non-covalent linking schemes, the covalent method was confirmed to be more effective for immobilizing a probe DNA. With the combined use of SnO 2 nanomaterial and the covalent linking scheme, the target DNA could be detected at a very low concentration of 10 fM. And the stability of SnO 2 nanomaterial under the experimental conditions was also compared with silicon nanowires. The findings strongly suggested that SnO 2 nanomaterial could be extensively applied in detections of biological samples with enhancing fluorescence property and high stability

  4. Method for detecting point mutations in DNA utilizing fluorescence energy transfer

    Science.gov (United States)

    Parkhurst, Lawrence J.; Parkhurst, Kay M.; Middendorf, Lyle

    2001-01-01

    A method for detecting point mutations in DNA using a fluorescently labeled oligomeric probe and Forster resonance energy transfer (FRET) is disclosed. The selected probe is initially labeled at each end with a fluorescence dye, which act together as a donor/acceptor pair for FRET. The fluorescence emission from the dyes changes dramatically from the duplex stage, wherein the probe is hybridized to the complementary strand of DNA, to the single strand stage, when the probe is melted to become detached from the DNA. The change in fluorescence is caused by the dyes coming into closer proximity after melting occurs and the probe becomes detached from the DNA strand. The change in fluorescence emission as a function of temperature is used to calculate the melting temperature of the complex or T.sub.m. In the case where there is a base mismatch between the probe and the DNA strand, indicating a point mutation, the T.sub.m has been found to be significantly lower than the T.sub.m for a perfectly match probelstand duplex. The present invention allows for the detection of the existence and magnitude of T.sub.m, which allows for the quick and accurate detection of a point mutation in the DNA strand and, in some applications, the determination of the approximate location of the mutation within the sequence.

  5. Fluorescent carbon nanoparticle-based lateral flow biosensor for ultrasensitive detection of DNA.

    Science.gov (United States)

    Takalkar, Sunitha; Baryeh, Kwaku; Liu, Guodong

    2017-12-15

    We report a fluorescent carbon nanoparticle (FCN)-based lateral flow biosensor for ultrasensitive detection of DNA. Fluorescent carbon nanoparticle with a diameter of around 15nm was used as a tag to label a detection DNA probe, which was complementary with the part of target DNA. A capture DNA probe was immobilized on the test zone of the lateral flow biosensor. Sandwich-type hybridization reactions among the FCN-labeled DNA probe, target DNA and capture DNA probe were performed on the lateral flow biosensor. In the presence of target DNA, FCNs were captured on the test zone of the biosensor and the fluorescent intensity of the captured FCNs was measured with a portable fluorescent reader. After systematic optimizations of experimental parameters (the components of running buffers, the concentration of detection DNA probe used in the preparation of FCN-DNA conjugates, the amount of FCN-DNA dispensed on the conjugate pad and the dispensing cycles of the capture DNA probes on the test-zone), the biosensor could detect a minimum concentration of 0.4 fM DNA. This study provides a rapid and low-cost approach for DNA detection with high sensitivity, showing great promise for clinical application and biomedical diagnosis. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes

    Science.gov (United States)

    Scardelletti, Maximilian C.; Varaljay, Vanessa

    2009-01-01

    The designed benchtop technique is primed to detect bacteria and viruses from antigenic surface marker proteins in solutions, initially water. This inclusive bio-immunoassay uniquely combines nanofiltration and near infrared (NIR) dyes conjugated to antibodies to isolate and distinguish microbial antigens, using laser excitation and spectrometric analysis. The project goals include detecting microorganisms aboard the International Space Station, space shuttle, Crew Exploration Vehicle (CEV), and human habitats on future Moon and Mars missions, ensuring astronaut safety. The technique is intended to improve and advance water contamination testing both commercially and environmentally as well. Lastly, this streamlined technique poses to greatly simplify and expedite testing of pathogens in complex matrices, such as blood, in hospital and laboratory clinics.

  7. Field portable mobile phone based fluorescence microscopy for detection of Giardia lamblia cysts in water samples

    Science.gov (United States)

    Ceylan Koydemir, Hatice; Gorocs, Zoltan; McLeod, Euan; Tseng, Derek; Ozcan, Aydogan

    2015-03-01

    Giardia lamblia is a waterborne parasite that causes an intestinal infection, known as giardiasis, and it is found not only in countries with inadequate sanitation and unsafe water but also streams and lakes of developed countries. Simple, sensitive, and rapid detection of this pathogen is important for monitoring of drinking water. Here we present a cost-effective and field portable mobile-phone based fluorescence microscopy platform designed for automated detection of Giardia lamblia cysts in large volume water samples (i.e., 10 ml) to be used in low-resource field settings. This fluorescence microscope is integrated with a disposable water-sampling cassette, which is based on a flow-through porous polycarbonate membrane and provides a wide surface area for fluorescence imaging and enumeration of the captured Giardia cysts on the membrane. Water sample of interest, containing fluorescently labeled Giardia cysts, is introduced into the absorbent pads that are in contact with the membrane in the cassette by capillary action, which eliminates the need for electrically driven flow for sample processing. Our fluorescence microscope weighs ~170 grams in total and has all the components of a regular microscope, capable of detecting individual fluorescently labeled cysts under light-emitting-diode (LED) based excitation. Including all the sample preparation, labeling and imaging steps, the entire measurement takes less than one hour for a sample volume of 10 ml. This mobile phone based compact and cost-effective fluorescent imaging platform together with its machine learning based cyst counting interface is easy to use and can even work in resource limited and field settings for spatio-temporal monitoring of water quality.

  8. Development of a dielectrophoresis-assisted surface plasmon resonance fluorescence biosensor for detection of bacteria

    Science.gov (United States)

    Kuroda, Chiaki; Iizuka, Ryota; Ohki, Yoshimichi; Fujimaki, Makoto

    2018-05-01

    To detect biological substances such as bacteria speedily and accurately, a dielectrophoresis-assisted surface plasmon resonance (SPR) fluorescence biosensor is being developed. Using Escherichia coli as a target organism, an appropriate voltage frequency to collect E. coli cells on indium tin oxide quadrupole electrodes by dielectrophoresis is analyzed. Then, E. coli is stained with 4‧,6-diamidino-2-phenylindole (DAPI). To clearly detect fluorescence signals from DAPI-stained E. coli cells, the sensor is optimized so that we can excite SPR on Al electrodes by illuminating 405 nm photons. As a result, the number of fluorescence signals is increased on the electrodes by the application of a low-frequency voltage. This indicates that E. coli cells with a lower permittivity than the surrounding water are collected by negative dielectrophoresis onto the electrodes where the electric field strength is lowest.

  9. Short-chain fluorescent tryptophan tags for on-line detection of functional recombinant proteins

    Directory of Open Access Journals (Sweden)

    Siepert Eva-Maria

    2012-09-01

    Full Text Available Abstract Background Conventional fluorescent proteins, such as GFP, its derivatives and flavin mononucleotide based fluorescent proteins (FbFPs are often used as fusion tags for detecting recombinant proteins during cultivation. These reporter tags are state-of-the-art; however, they have some drawbacks, which can make on-line monitoring challenging. It is discussed in the literature that the large molecular size of proteins of the GFP family may stress the host cell metabolism during production. In addition, fluorophore formation of GFP derivatives is oxygen-dependent resulting in a lag-time between expression and fluorescence detection and the maturation of the protein is suppressed under oxygen-limited conditions. On the contrary, FbFPs are also applicable in an oxygen-limited or even anaerobic environment but are still quite large (58% of the size of GFP. Results As an alternative to common fluorescent tags we developed five novel tags based on clustered tryptophan residues, called W-tags. They are only 5-11% of the size of GFP. Based on the property of tryptophan to fluoresce in absence of oxygen it is reasonable to assume that the functionality of our W-tags is also given under anaerobic conditions. We fused these W-tags to a recombinant protein model, the anti-CD30 receptor single-chain fragment variable antibody (scFv Ki-4(scFv and the anti-MucI single-chain fragment variable M12(scFv. During cultivation in Microtiter plates, the overall tryptophan fluorescence intensity of all cultures was measured on-line for monitoring product formation via the different W-tags. After correlation of the scattered light signal representing biomass concentration and tryptophan fluorescence for the uninduced cultures, the fluorescence originating from the biomass was subtracted from the overall tryptophan signal. The resulting signal, thus, represents the product fluorescence of the tagged and untagged antibody fragments. The product fluorescence signal

  10. Fluorescence correlation spectroscopy: Ultrasensitive detection in clear and turbid media

    Science.gov (United States)

    Tahari, Abdel Kader

    In this work, I describe the development of a simple, inexpensive, and powerful alternative technique to detect and analyze, without enrichment, extremely low concentrations of cells, bacteria, viruses, and protein aggregates in turbid fluids for clinical and biotechnological applications. The anticipated applications of this technique are many. They range from the determination of the somatic cell count in milk for the dairy industry, to the enumeration and characterization of microorganisms in environmental microbiology and the food industry, and to the fast and ultrasensitive detection of protein aggregates for the diagnosis of Alzheimer's and other neurodegenerative diseases in clinical medicine. A prototype instrument has been built and allowed the detection and quantification of particles down to a few per milliliter in short scanning times. It consists of a small microscope that has a horizontal geometry and a mechanical instrument that holds a cylindrical cuvette (1 cm in diameter) with two motors that provide a rotational and a slower vertical inversion motions. The illumination focus is centered about 200 mum from the wall of the cuvette inside the sample. The total volume that is explored is large (˜1ml/min for bright particles). The data is analyzed with a correlation filter program based on particle passage pattern recognition. I will also describe further work on improving the sensitivity of the technique, expanding it for multiple-species discrimination and enumeration, and testing the prototype device in actual clinical and biotechnological applications. The main clinical application of this project seeks to establish conditions and use this new technique to quantify and size-analyze oligomeric complexes of the Alzheimer's disease beta-peptide in cerebrospinal fluid and other body fluids as a molecular biomarker for persons at risk of Alzheimer's disease dementia. The technology could potentially be extended to the diagnosis and therapeutic

  11. A new screening method to detect proximal dental caries using fluorescence imaging.

    Science.gov (United States)

    Kim, Eun-Soo; Lee, Eun-Song; Kang, Si-Mook; Jung, Eun-Ha; de Josselin de Jong, Elbert; Jung, Hoi-In; Kim, Baek-Il

    2017-12-01

    This study aimed to assess the screening performance of the quantitative light-induced fluorescence (QLF) technology to detect proximal caries using both fluorescence loss and red fluorescence in a clinical situation. Moreover, a new simplified QLF score for the proximal caries (QS-Proximal) is proposed and its validity for detecting proximal caries was evaluated as well. This clinical study included 280 proximal surfaces, which were assessed by visual-tactile and radiographic examinations and scored by each scoring system according to lesion severity. The occlusal QLF images were analysed in two different ways: (1) a quantitative analysis producing fluorescence loss (ΔF) and red fluorescence (ΔR) parameters; and (2) a new QLF scoring index. For both quantitative parameters and QS-Proximal, the sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) were calculated as a function of the radiographic scoring index at the enamel and dentine caries levels. Both ΔF and ΔR showed excellent AUROC values at the dentine caries level (ΔF=0.860, ΔR=0.902) whereas a relatively lower value was observed at the enamel caries level (ΔF=0.655, ΔR=0.686). The QS-Proximal also showed excellent AUROC ranged from 0.826 to 0.864 for detecting proximal caries at the dentine level. The QS-Proximal, which represents fluorescence changes, showed excellent performance in detecting proximal caries using the radiographic score as the gold standard. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Multiplexed Detection of Attomoles of Nucleic Acids Using Fluorescent Nanoparticle Counting Platform.

    Science.gov (United States)

    Pei, Xiaojing; Yin, Haoyan; Lai, Tiancheng; Zhang, Junlong; Liu, Feng; Xu, Xiao; Li, Na

    2018-01-16

    The sensitive multiplexed detection of nucleic acids in a single sample by a simple manner is of pivotal importance for the diagnosis and therapy of human diseases. Herein, we constructed an automatic fluorescent nanoparticle (FNP) counting platform with a common fluorescence microscopic imaging setup for nonamplification multiplexed detection of attomoles of nucleic acids. Taking the advantages of the highly bright, multicolor emitting FNPs and magnetic separation, the platform enables sensitive multiplexed detection without the need for extra fluorescent labels. Quantification for multiplex DNAs, multiplex microRNAs (miRNA), as well as a DNA and miRNA mixture was achieved with a similar dynamic range, a limit of detection down to 5 amol (5 μL detection volume), and a 81-115% spike recovery from different biological sample matrices. In particular, the sensitivity for multiplex miRNA is by far among the highest without using amplification or the lock nucleic acid hybridization enhancement strategy. Results regarding miRNA-141 from four different cell lines were agreeable with those of the quantitative reverse transcription polymerase chain reaction. Simultaneous detection of miRNA-141 and miRNA-21 in four different cell lines yielded consistent results with publications, indicating the potential for monitoring multiplex miRNA expression associated with the collaborative regulation of important cellular events. This work expands the rule set of multiplex nucleic acid detection strategies and shows promising potential application in clinical diagnosis.

  13. Organ transplant tissue rejection: detection and staging by fluorescence spectroscopy

    Science.gov (United States)

    MacAulay, Calum E.; Whitehead, Peter D.; McManus, Bruce; Zeng, Haishan; Wilson-McManus, Janet; MacKinnon, Nick; Morgan, David C.; Dong, Chunming; Gerla, Paul; Kenyon, Jennifer

    1998-07-01

    Patients receiving heart or other organ transplants usually require some level of anti-rejection drug therapy, most commonly cyclosporine. The rejection status of the organ must be monitored to determine the optimal anti-rejection drug therapy. The current method for monitoring post-transplant rejection status of heart transplant patients consists of taking biopsies from the right ventricle. In this work we have developed a system employing optical and signal-processing techniques that will allow a cardiologist to measure spectral changes associated with tissue rejection using an optical catheter probe. The system employs time gated illumination and detection systems to deal with the dynamic signal acquisition problems associated with in vivo measurements of a beating heart. Spectral data processing software evaluates and processes the data to produce a simple numerical score. Results of measurements made on 100 excised transplanted isograft and allograft rat hearts have demonstrated the ability of the system to detect the presence of rejection and to accurately correlate the spectroscopic results with the ISHLT (International Society for Heart and Lung Transplantation) stage of rejection determined by histopathology. In vivo measurements using a pig transplant model are now in process.

  14. Peptide-assembled graphene oxide as fluorescent turn-on sensor for ultrasensitive Lipopolysaccharide (Endotoxin detection

    Directory of Open Access Journals (Sweden)

    Seng Koon Lim

    2014-06-01

    Full Text Available Introduction: Lipopolysaccharide (LPS, or endotoxin, a major component in the outer cell membrane of Gram-negative bacteria is a very powerful and toxic inflammatory stimulator, resulting in sepsis or septic shock, a significant medical problem affecting about 700 000 patients and causing 250 000 casualties annually in the United States itself. The detection of LPS is highly importance. However, the currently used enzymatic limulus amebocyte lysate assay is highly susceptible to changes in temperature and pH, interference factors, and requires cumbersome sample preparation. A more cost-effective, sensitive and robust detection method is needed. Objective: To design and develop biosensor for LPS detection by assembling a LPS-binding peptide (as LPS receptor with graphene oxide (GO, as fluorescence quencher. Methods: GO was synthesized using a modified Hummer’s method. A synthetic LPS-binding peptide was designed, fluorescent labelled, and assembled with GO in PBS buffer solution. The fluorescence recovery of the peptide-GO was measured upon addition of LPS from Gram negative bacteria: E. coli, K. pneumoniae, Samonella Thyphosa, P. aeruginosa, as well as living pathogenic bacteria. Specificity tests were conducted with various biological molecules to evaluate the sensing performance. Results & Discussion: Specific binding of LPS with peptide release the peptides from GO, resulting in fluorescence recovery, allowing ultrasensitive detection of LPS with the limit of detection of 130 pM, the most sensitive synthetic LPS sensors to-date. The LPS sensor is highly selective to LPS than other biological species. Conclusion: We developed a peptide-GO assembled fluorescence sensor for ultrasensitive and specific LPS/endotoxin detection. This is the most sensitive synthetic LPS sensor reported in the world.

  15. Clinical performance of fluorescence-based methods for detection of occlusal caries lesions in primary teeth

    Directory of Open Access Journals (Sweden)

    Laura Regina Antunes PONTES

    2017-11-01

    Full Text Available Abstract We aimed to investigate the performance of fluorescence-based methods (FBMs, compared to visual inspection after histological validation, in detecting and assessing the activity status of occlusal carious lesions in primary teeth. One examiner evaluated 50 primary molars close to exfoliation in 24 children. Teeth were assessed using quantitative light-induced fluorescence (QLF and pen-type laser fluorescence (LFpen. After exfoliation, histological validation was performed. Teeth were cut and sections were evaluated for lesion depth and activity status (after utilization of a pH indicator under a stereomicroscope. Parameters related to the performance of the methods in detecting caries lesions at two thresholds (initial and dentin lesions were calculated. Regarding the activity status, lesions were classified into sound+inactive or active, and the area under the ROC curve and the diagnostic odds ratio values of the methods were calculated and compared. Evaluation of red fluorescence using QLF presented higher sensitivity but lower specificity than visual inspection in detecting dentin caries lesions. However, QLF considering different parameters and LFpen had similar performance to that obtained with visual inspection. Regarding activity assessment, all FBMs and visual inspection also presented similar performance. In conclusion, FBMs did not prove advantageous for the detection and activity assessment of occlusal caries lesions in primary molars when compared to visual inspection.

  16. Clinical performance of fluorescence-based methods for detection of occlusal caries lesions in primary teeth.

    Science.gov (United States)

    Pontes, Laura Regina Antunes; Novaes, Tatiane Fernandes; Moro, Bruna Lorena Pereira; Braga, Mariana Minatel; Mendes, Fausto Medeiros

    2017-11-06

    We aimed to investigate the performance of fluorescence-based methods (FBMs), compared to visual inspection after histological validation, in detecting and assessing the activity status of occlusal carious lesions in primary teeth. One examiner evaluated 50 primary molars close to exfoliation in 24 children. Teeth were assessed using quantitative light-induced fluorescence (QLF) and pen-type laser fluorescence (LFpen). After exfoliation, histological validation was performed. Teeth were cut and sections were evaluated for lesion depth and activity status (after utilization of a pH indicator) under a stereomicroscope. Parameters related to the performance of the methods in detecting caries lesions at two thresholds (initial and dentin lesions) were calculated. Regarding the activity status, lesions were classified into sound+inactive or active, and the area under the ROC curve and the diagnostic odds ratio values of the methods were calculated and compared. Evaluation of red fluorescence using QLF presented higher sensitivity but lower specificity than visual inspection in detecting dentin caries lesions. However, QLF considering different parameters and LFpen had similar performance to that obtained with visual inspection. Regarding activity assessment, all FBMs and visual inspection also presented similar performance. In conclusion, FBMs did not prove advantageous for the detection and activity assessment of occlusal caries lesions in primary molars when compared to visual inspection.

  17. Detection of chromosome abnormalities by quantitative fluorescent PCR in ectopic pregnancies

    NARCIS (Netherlands)

    Goddijn, Mariette; van Stralen, Marja; Schuring-Blom, Heleen; Redeker, Bert; van Leeuwen, Liesbeth; Repping, Sjoerd; Leschot, Nico; van der Veen, Fulco

    2005-01-01

    Objective: To evaluate the potential value of quantitative fluorescent polymerase chain reaction (QF-PCR) in the detection of chromosome abnormalities in ectopic pregnancies. Methods: Seventy chorionic villi samples of ectopic pregnancies were studied by QF-PCR. Primers for chromosomes 16, 21, X and

  18. Gold Nanoparticles-Coated SU-8 for Sensitive Fluorescence-Based Detections of DNA

    DEFF Research Database (Denmark)

    Cao, Cuong; Birtwell, Sam W.; Høgberg, Jonas

    2012-01-01

    that use fluorescence as the predominant detection workhorse. Here, we show that deposition of a thin gold nanoparticles layer onto the SU-8 surface significantly reduces the autofluorescence of the coated SU-8 surface by as much as 81% compared to bare SU-8. Furthermore, DNA probes can easily...

  19. A Graphene Oxide-Based Fluorescent Method for the Detection of Human Chorionic Gonadotropin.

    Science.gov (United States)

    Xia, Ning; Wang, Xin; Liu, Lin

    2016-10-13

    Human chorionic gonadotropin (hCG) has been regarded as a biomarker for the diagnosis of pregnancy and some cancers. Because the currently used methods (e.g., disposable Point of Care Testing (POCT) device) for hCG detection require the use of many less stable antibodies, simple and cost-effective methods for the sensitive and selective detection of hCG have always been desired. In this work, we have developed a graphene oxide (GO)-based fluorescent platform for the detection of hCG using a fluorescein isothiocyanate (FITC)-labeled hCG-specific binding peptide aptamer (denoted as FITC-PPLRINRHILTR) as the probe, which can be manufactured cheaply and consistently. Specifically, FITC-PPLRINRHILTR adsorbed onto the surface of GO via electrostatic interaction showed a poor fluorescence signal. The specific binding of hCG to FITC-PPLRINRHILTR resulted in the release of the peptide from the GO surface. As a result, an enhanced fluorescence signal was observed. The fluorescence intensity was directly proportional to the hCG concentration in the range of 0.05-20 IU/mL. The detection limit was found to be 20 mIU/mL. The amenability of the strategy to hCG analysis in biological fluids was demonstrated by assaying hCG in the urine samples.

  20. Detection of Helicobacter pylori in the Gastric Mucosa by Fluorescence In Vivo Hybridization

    DEFF Research Database (Denmark)

    Fontenete, Silvia; Leite, Marina; Figueiredo, Céu

    2017-01-01

    In this chapter, we describe a fluorescence in vivo hybridization (FIVH) protocol, using nucleic acid probes, for the detection of the bacterium Helicobacter pylori in the gastric mucosa of an infected C57BL/6 mouse model. This protocol should be easily extended to other microorganisms not only...

  1. Simultaneous and consecutive two-photon excited fluorescence detection in conventional-size liquid chromatography.

    NARCIS (Netherlands)

    Gooijer, C.; Brinkman, U.A.T.; Velthorst, N.H.; van de Nesse, R.J.; van der Wegen, R.J.

    1995-01-01

    The applicability of two-photon excitation (TPE) for fluorescence detection in flow dynamic systems was explored. Emphasis was on conventional-size liquid chromatography (LC) and a direct comparison was made with one-photon excitation (OPE) by the use of standard laser- and lamp excitation.

  2. Bio-inspired photonic-crystal microchip for fluorescent ultratrace detection.

    Science.gov (United States)

    Hou, Jue; Zhang, Huacheng; Yang, Qiang; Li, Mingzhu; Song, Yanlin; Jiang, Lei

    2014-06-02

    Ultratrace detection attracts great interest because it is still a challenge to the early diagnosis and drug testing. Enriching the targets from highly diluted solutions to the sensitive area is a promising method. Inspired by the fog-collecting structure on Stenocara beetle's back, a photonic-crystal (PC) microchip with hydrophilic-hydrophobic micropattern was fabricated by inkjet printing. This device was used to realize high-sensitive ultratrace detection of fluorescence analytes and fluorophore-based assays. Coupled with the fluorescence enhancement effect of a PC, detection down to 10(-16) mol L(-1) was achieved. This design can be combined with biophotonic devices for the detection of drugs, diseases, and pollutions of the ecosystem. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Fluorescence-based lateral flow assays for rapid oral fluid roadside detection of cannabis use.

    Science.gov (United States)

    Plouffe, Brian D; Murthy, Shashi K

    2017-02-01

    With the recent worldwide changes in the legalization of marijuana, there is a significant need for rapid, roadside screening test for driving under the influence of drugs. A robust, sensitive, lateral flow assay has been developed to detect recent use via oral-fluid testing for Δ 9 -tetrahydrocannabinol (THC). This proof-of-concept assay uses a fluorescent-based immunoassay detection of polymeric beads, conjugated to antibodies against native THC. The fluorescent technique allows for significantly lower limits of detection and higher precision determination of recent marijuana use without the use of urine or blood sampling-thus allowing for roadside identification. Detection levels of 0.01 ng/mL were distinguished from background and the lower limit of quantification was determined to approach 1 ng/mL. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Red fluorescence imaging for dental plaque detection and quantification: pilot study

    Science.gov (United States)

    Liu, Zhao; Gomez, Juliana; Khan, Soniya; Peru, Debbie; Ellwood, Roger

    2017-09-01

    The red fluorescence of dental plaque originating from porphyrins in oral bacteria may allow visualization, detection, and scoring of plaque without disclosing agents. Two studies were conducted. The first included 24 healthy participants who abstained from oral hygiene for 24 h. Dental plaque was collected from tooth surfaces, and a 10% solution was prepared. These were scanned by a molecular spectrometer to identify the optimum excitation and emission wavelengths of plaque for developing a red fluorescence imaging system. Fourteen healthy subjects completed the second study. After a washout period (1 week), participants had a prophylaxis at baseline and abstained from oral hygiene during the study. They were monitored using the fluorescence imaging system at baseline, 24 h, and 48 h. A dentist clinically assessed plaque after disclosing and on red fluorescence images. Three descriptors were extracted from images and a RUSBoost classifier derived computer fluorescence scores through cross-validation. Red fluorescence plaque levels increased during the 48-h accumulation. Plaque progression was identified by dentist assessment and computer analysis, presenting significant differences between visits at tooth and subject levels (poral hygiene assessment.

  5. Spectroscopic detection of fluorescent protein marker gene activity in genetically modified plants

    Science.gov (United States)

    Liew, O. W.; Chong, Jenny P. C.; Asundi, Anand K.

    2005-04-01

    This work focuses on developing a portable fibre optic fluorescence analyser for rapid identification of genetically modified plants tagged with a fluorescent marker gene. Independent transgenic tobacco plant lines expressing the enhanced green fluorescence protein (EGFP) gene were regenerated following Agrobacterium-mediated gene transfer. Molecular characterisation of these plant lines was carried out at the DNA level by PCR screening to confirm their transgenic status. Conventional transgene expression analysis was then carried out at the RNA level by RT-PCR and at the protein level by Western blotting using anti-GFP rabbit antiserum. The amount of plant-expressed EGFP on a Western blot was quantified against known amounts of purified EGFP by scanning densitometry. The expression level of EGFP in transformed plants was found to range from 0.1 - 0.6% of total extractable protein. A comparison between conventional western analysis of transformants and direct spectroscopic quantification using the fibre optic fluorescence analyser was made. The results showed that spectroscopic measurements of fluorescence emission from strong EGFP expressors correlated positively with Western blot data. However, the fluorescence analyser was also able to identify weakly expressing plant transformants below the detection limit of colorimetric Western blotting.

  6. Detection of Bacterial Endospores in Soil by Terbium Fluorescence

    Directory of Open Access Journals (Sweden)

    Andrea Brandes Ammann

    2011-01-01

    Full Text Available Spore formation is a survival mechanism of microorganisms when facing unfavorable environmental conditions resulting in “dormant” states. We investigated the occurrence of bacterial endospores in soils from various locations including grasslands (pasture, meadow, allotment gardens, and forests, as well as fluvial sediments. Bacterial spores are characterized by their high content of dipicolinic acid (DPA. In the presence of terbium, DPA forms a complex showing a distinctive photoluminescence spectrum. DPA was released from soil by microwaving or autoclaving. The addition of aluminium chloride reduced signal quenching by interfering compounds such as phosphate. The highest spore content (up to 109 spores per gram of dry soil was found in grassland soils. Spore content is related to soil type, to soil depth, and to soil carbon-to-nitrogen ratio. Our study might provide a basis for the detection of “hot spots” of bacterial spores in soil.

  7. In-vivo optical detection of cancer using chlorin e6 – polyvinylpyrrolidone induced fluorescence imaging and spectroscopy

    International Nuclear Information System (INIS)

    Chin, William WL; Thong, Patricia SP; Bhuvaneswari, Ramaswamy; Soo, Khee Chee; Heng, Paul WS; Olivo, Malini

    2009-01-01

    Photosensitizer based fluorescence imaging and spectroscopy is fast becoming a promising approach for cancer detection. The purpose of this study was to examine the use of the photosensitizer chlorin e6 (Ce6) formulated in polyvinylpyrrolidone (PVP) as a potential exogenous fluorophore for fluorescence imaging and spectroscopic detection of human cancer tissue xenografted in preclinical models as well as in a patient. Fluorescence imaging was performed on MGH human bladder tumor xenografted on both the chick chorioallantoic membrane (CAM) and the murine model using a fluorescence endoscopy imaging system. In addition, fiber optic based fluorescence spectroscopy was performed on tumors and various normal organs in the same mice to validate the macroscopic images. In one patient, fluorescence imaging was performed on angiosarcoma lesions and normal skin in conjunction with fluorescence spectroscopy to validate Ce6-PVP induced fluorescence visual assessment of the lesions. Margins of tumor xenografts in the CAM model were clearly outlined under fluorescence imaging. Ce6-PVP-induced fluorescence imaging yielded a specificity of 83% on the CAM model. In mice, fluorescence intensity of Ce6-PVP was higher in bladder tumor compared to adjacent muscle and normal bladder. Clinical results confirmed that fluorescence imaging clearly captured the fluorescence of Ce6-PVP in angiosarcoma lesions and good correlation was found between fluorescence imaging and spectral measurement in the patient. Combination of Ce6-PVP induced fluorescence imaging and spectroscopy could allow for optical detection and discrimination between cancer and the surrounding normal tissues. Ce6-PVP seems to be a promising fluorophore for fluorescence diagnosis of cancer

  8. Indirect immunofluorescence detection of E. coli O157:H7 with fluorescent silica nanoparticles.

    Science.gov (United States)

    Chen, Ze-Zhong; Cai, Li; Chen, Min-Yan; Lin, Yi; Pang, Dai-Wen; Tang, Hong-Wu

    2015-04-15

    A method of fluorescent nanoparticle-based indirect immunofluorescence assay using either fluorescence microscopy or flow cytometry for the rapid detection of pathogenic Escherichia coli O157:H7 was developed. The dye-doped silica nanoparticles (NPs) were synthesized using W/O microemulsion methods with the combination of 3-aminopropyltriethoxysilane (APTES) and fluorescein isothiocyanate (FITC) and polymerization reaction with carboxyethylsilanetriol sodium salt (CEOS). Protein A was immobilized at the surface of the NPs by covalent binding to the carboxyl linkers and the surface coverage of Protein A on NPs was determined by the Bradford method. Rabbit anti-E. Coli O157:H7 antibody was used as primary antibody to recognize E. coli O157:H7 and then antibody binding protein (Protein A) labeled with FITC-doped silica NPs (FSiNPs) was used to generate fluorescent signal. With this method, E. Coli O157:H7 in buffer and bacterial mixture was detected. In addition, E. coli O157:H7 in several spiked background beef samples were measured with satisfactory results. Therefore, the FSiNPs are applicable in signal-amplified bioassay of pathogens due to their excellent capabilities such as brighter fluorescence and higher photostability than the direct use of conventional fluorescent dyes. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. A hydroxyl radical detection system using gas expansion and fast gating laser-induced fluorescence techniques.

    Science.gov (United States)

    Chen, Hao; Hu, Renzhi; Xie, Pinhua; Xing, Xingbiao; Ling, Liuyi; Li, Zhiyan; Wang, Fengyang; Wang, Yihui; Liu, Jianguo; Liu, Wenqing

    2018-03-01

    An OH radical measurement instrument based on Fluorescence Assay by Gas Expansion (FAGE) has been developed in our laboratory. Ambient air is introduced into a low-pressure fluorescence cell through a pinhole aperture and irradiated by a dye laser at a high repetition rate of 8.5kHz. The OH radical is both excited and detected at 308nm using A-X(0,0) band. To satisfy the high efficiency needs of fluorescence collection and detection, a 4-lens optical system and a self-designed gated photomultiplier (PMT) is used, and gating is actualized by switching the voltage applied on the PMT dynodes. A micro channel photomultiplier (MCP) is also prepared for fluorescence detection. Then the weak signal is accumulated by a photon counter in a specific timing. The OH radical excitation spectrum range in the wavelength of 307.82-308.2nm is detected and the excited line for OH detection is determined to be Q 1 (2) line. The calibration of the FAGE system is researched by using simultaneous photolysis of H 2 O and O 2 . The minimum detection limit of the instrument using gated PMT is determined to be 9.4×10 5 molecules/cm 3 , and the sensitivity is 9.5×10 -7 cps/(OH·cm -3 ), with a signal-to-noise ratio of 2 and an integration time of 60sec, while OH detection limit and the detection sensitivity using MCP is calculated to be 1.6×10 5 molecules/cm 3 and 2.3×10 -6 cps/(OH·cm -3 ). The laboratory OH radical measurement is carried out and results show that the proposed system can be used for atmospheric OH radical measurement. Copyright © 2017. Published by Elsevier B.V.

  10. New Fluorescent Nanoparticles for Ultrasensitive Detection of Nucleic Acids by Optical Methods

    DEFF Research Database (Denmark)

    Mulberg, Mads Westergaard; Taskova, Maria; Thomsen, Rasmus P.

    2017-01-01

    derivatives have higher photostability, brighter fluorescence and hence dramatically lower limits of target detection than the individual organic dyes. These properties make them useful in approaches directed towards ultrasensitive detection of nucleic acids, in particular for imaging and in vitro diagnostics......For decades the detection of nucleic acids and their interactions at low abundances has been a challenging task that has thus far been solved by enzymatic target amplification. In this work we aimed at developing efficient tools for amplification-free nucleic acid detection, which resulted...

  11. A new sensitive and selective fluorescence probe for detection of cyanide.

    Science.gov (United States)

    Duan, Yi-Long; Zheng, Yan-Song

    2013-03-30

    A class of new fluorescence probe α-p-trifluoroacetamidophenyl-4-alkoxycinnamonitrile for detection of cyanide anion was synthesized by the trifluoroacetylation of the fluorophore α-p-aminophenyl-4-alkoxycinnamonitrile. It was found that the probe could selectively detect cyanide anions, even in the presence of hydrogen sulfite and dicarbonate anions which were reported to easily interfere with the detection. The concentration of the cyanide anions that could be detected was as low as 1.0 μM. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Unusual Fluorescent Responses of Morpholine-functionalized Fluorescent Probes to pH via Manipulation of BODIPY's HOMO and LUMO Energy Orbitals for Intracellular pH Detection.

    Science.gov (United States)

    Zhang, Jingtuo; Yang, Mu; Mazi, Wafa; Adhikari, Kapil; Fang, Mingxi; Xie, Fei; Valenzano, Loredana; Tiwari, Ashutosh; Luo, Fen-Tair; Liu, Haiying

    2016-02-26

    Three uncommon morpholine-based fluorescent probes ( A , B and C ) for pH were prepared by introducing morpholine residues to BODIPY dyes at 4,4'- and 2,6-positions, respectively. In contrast to morpholine-based fluorescent probes for pH reported in literature, these fluorescent probes display high fluorescence in a basic condition while they exhibit very weak fluorescence in an acidic condition. The theoretical calculation confirmed that morpholine is unable to function as either an electron donor or an electron acceptor to quench the BODIPY fluorescence in the neutral and basic condition via photo-induced electron transfer (PET) mechanism because the LUMO energy of morpholine is higher than those of the BODIPY dyes while its HOMO energy is lower than those of the BODIPY dyes. However, the protonation of tertiary amines of the morpholine residues in an acidic environment leads to fluorescence quenching of the BODIPY dyes via d-PET mechanism. The fluorescence quenching is because the protonation effectively decreases the LUMO energy which locates between the HOMO and LUMO energies of the BODIPY dyes. Fluorescent probe C with deep-red emission has been successfully used to detect pH changes in mammalian cells.

  13. A miniaturised image based fluorescence detection system for point-of-care-testing of cocaine abuse

    Science.gov (United States)

    Walczak, Rafał; Krüger, Jan; Moynihan, Shane

    2015-08-01

    In this paper, we describe a miniaturised image-based fluorescence detection system and demonstrate its viability as a highly sensitive tool for point-of-care-analysis of drugs of abuse in human sweat with a focus on monitor individuals for drugs of abuse. Investigations of miniaturised and low power optoelectronic configurations and methodologies for real-time image analysis were successfully carried out. The miniaturised fluorescence detection system was validated against a reference detection system under controlled laboratory conditions by analysing spiked sweat samples in dip stick and then strip with sample pad. As a result of the validation studies, a 1 ng mL-1 limit of detection of cocaine in sweat and full agreement of test results with the reference detection system can be reported. Results of the investigations open the way towards a detection system that integrates a hand-held fluorescence reader and a wearable skinpatch, and which can collect and in situ analyse sweat for the presence of cocaine at any point for up to tenths hours.

  14. Development of a fluorescence lidar for biological aerosol detection in the air

    Science.gov (United States)

    He, Tingyao; Rao, Zhimin

    2017-10-01

    In order to investigate biological aerosols in the air, a fluorescence lidar has being developed at Laser Radar Center of Remote Sensing of Atmosphere, Xi'an University of Technology. The fluorescence lidar is constructed with a pulsed Nd:YAG laser, employing at based harmonic (1064 nm), second harmonic (532 nm) and fourth harmonic (266 nm) simultaneously, with a repetition rate of 10 Hz. A 250 mm diameter custom telescope is used to collect optical spectra ranging from 260-1100 nm. In the Infrared detection, an avalanche diode (APD) is used, and two photomultiplier tubes (PMTs) for two linear orthogonal polarization detection at a wavelength of 532 nm. Range-resolved fluorescence signals are collected in 32 channels of compound PMT sensor coupled with Czerny-Turner spectrograph. Based on the current configurations, we performed a series of numerical simulations to estimate the maximal detectable ranges and the minimal detectable concentrations of biological aerosols with various conditions. With a relative error of less than 10%, simulated results show that the system is able to monitor biological aerosols within detected distances of 1.3 km and of 2.0 km at daytime and nighttime, respectively. The developing fluorescence lidar is also capable to identify a minimum concentration of bio-aerosols at about 150 particles;L-1 with daytime operation and 100 particles;L-1 with nighttime at a distance of about 0.1 km. We truly believe that the fluorescence lidar could be spread in the field of remote sensing of biological aerosols in the near future.

  15. Near-infrared fluorescence sentinel lymph node detection in gastric cancer: A pilot study

    Science.gov (United States)

    Tummers, Quirijn R J G; Boogerd, Leonora S F; de Steur, Wobbe O; Verbeek, Floris P R; Boonstra, Martin C; Handgraaf, Henricus J M; Frangioni, John V; van de Velde, Cornelis J H; Hartgrink, Henk H; Vahrmeijer, Alexander L

    2016-01-01

    AIM: To investigate feasibility and accuracy of near-infrared fluorescence imaging using indocyanine green: nanocolloid for sentinel lymph node (SLN) detection in gastric cancer. METHODS: A prospective, single-institution, phase I feasibility trial was conducted. Patients suffering from gastric cancer and planned for gastrectomy were included. During surgery, a subserosal injection of 1.6 mL ICG:Nanocoll was administered around the tumor. NIR fluorescence imaging of the abdominal cavity was performed using the Mini-FLARE™ NIR fluorescence imaging system. Lymphatic pathways and SLNs were visualized. Of every detected SLN, the corresponding lymph node station, signal-to-background ratio and histopathological diagnosis was determined. Patients underwent standard-of-care gastrectomy. Detected SLNs outside the standard dissection planes were also resected and evaluated. RESULTS: Twenty-six patients were enrolled. Four patients were excluded because distant metastases were found during surgery or due to technical failure of the injection. In 21 of the remaining 22 patients, at least 1 SLN was detected by NIR Fluorescence imaging (mean 3.1 SLNs; range 1-6). In 8 of the 21 patients, tumor-positive LNs were found. Overall accuracy of the technique was 90% (70%-99%; 95%CI), which decreased by higher pT-stage (100%, 100%, 100%, 90%, 0% for respectively Tx, T1, T2, T3, T4 tumors). All NIR-negative SLNs were completely effaced by tumor. Mean fluorescence signal-to-background ratio of SLNs was 4.4 (range 1.4-19.8). In 8 of the 21 patients, SLNs outside the standard resection plane were identified, that contained malignant cells in 2 patients. CONCLUSION: This study shows successful use of ICG:Nanocoll as lymphatic tracer for SLN detection in gastric cancer. Moreover, tumor-containing LNs outside the standard dissection planes were identified. PMID:27053856

  16. Detection of Buried Human Remains Using Bioreporter Fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Vass, A. Dr.; Singleton, G. B.

    2001-10-01

    The search for buried human remains is a difficult, laborious and time-consuming task for law enforcement agencies. This study was conducted as a proof of principle demonstration to test the concept of using bioreporter microorganisms as a means to cover large areas in such a search. These bioreporter microorganisms are affected by a particular component of decaying organic matter that is distinct from decaying vegetation. The diamino compounds cadaverine and putrescine were selected as target compounds for the proof-of-principle investigation, and a search for microorganisms and genes that are responsive to either of these compounds was conducted. One recombinant clone was singled out for characterization based on its response to putrescine. The study results show that small concentrations of putrescine increased expression from this bioreporter construct. Although the level of increase was small (making it difficult to distinguish the signal from background), the results demonstrate the principle that bioreporters can be used to detect compounds resulting from decaying human remains and suggest that a wider search for target compounds should be conducted.

  17. Dielectric barrier discharge plasma atomizer for hydride generation atomic absorption spectrometry-Performance evaluation for selenium

    Czech Academy of Sciences Publication Activity Database

    Duben, Ondřej; Boušek, J.; Dědina, Jiří; Kratzer, Jan

    2015-01-01

    Roč. 111, SEP (2015), s. 57-63 ISSN 0584-8547 Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * hydride generation-atomic absorption spectrometry * selenium Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.289, year: 2015

  18. COMPREHENSIVE ANALYSIS OF BIOLOGICALLY RELEVANT ARSENICALS BY PH-SELECTIVE HYDRIDE GENERATION-ATOMIC ABSORPTION SPECTROMETRY

    Science.gov (United States)

    A method based on pH-selective generation and separation of arsines is commonly used for analysis of inorganic, methylated, and dimethylated trivalent and pentavalent arsenicals by hydride generation-atomic absorption spectrometry (HG-AAS). We have optimized this method to pe...

  19. Dielectric barrier discharge plasma atomizer for hydride generation atomic absorption spectrometry-Performance evaluation for selenium

    Czech Academy of Sciences Publication Activity Database

    Duben, Ondřej; Boušek, J.; Dědina, Jiří; Kratzer, Jan

    2015-01-01

    Roč. 111, SEP (2015), s. 57-63 ISSN 0584-8547 Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * hydride generation- atomic absorption spectrometry * selenium Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.289, year: 2015

  20. Sensitive detection of mercury (II) ion using water-soluble captopril-stabilized fluorescent gold nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Jiu-Ju; Huang, Hong; Chen, Wei-Jie; Chen, Jian-Rong; Lin, Hong-Jun; Wang, Ai-Jun, E-mail: ajwang@zjnu.cn

    2013-07-01

    In our work, a simple, facile, and green method was developed for the synthesis of water-soluble and well-dispersed fluorescent gold nanoparticles (Au NPs) within 5 min, using captopril as a capping agent. The as-prepared Au NPs showed strong emission at 414 nm, with a quantum yield of 5.5%. The fluorescence of the Au NPs can be strongly quenched by mercury (II) ion (Hg{sup 2+}) due to the stronger interactions between thiolates (RS{sup −}) and Hg{sup 2+}. It was applied to the detection of Hg{sup 2+} in water samples in the linear ranges of 0.033–0.133 μM and 0.167–2.500 μM, with a detection limit of 0.017 μM. Therefore, the as-prepared Au NPs can meet the requirement for monitoring Hg{sup 2+} in environmental samples. - Graphical abstract: In this work, we developed a simple, fast and facile method for the preparation of water-soluble and fluorescent gold nanoparticles (Au NPs). The trace existence of Hg{sup 2+} could strongly quench the fluorescence of the Au NPs. The Au NPs were used to detect highly toxic Hg{sup 2+} in water samples with high sensitivity and selectivity. Highlights: ► Water-soluble fluorescent Au NPs stabilized by captopril ► The synthesis procedure was simple, fast and facile. ► The fluorescence of the Au NPs can be strongly quenched by Hg{sup 2+}. ► The Au NPs were used to the assay of Hg{sup 2+} in water samples with high sensitivity and selectivity.

  1. Highly selective and rapidly responsive fluorescent probe for hydrogen sulfide detection in wine.

    Science.gov (United States)

    Wang, Hao; Wang, Jialin; Yang, Shaoxiang; Tian, Hongyu; Liu, Yongguo; Sun, Baoguo

    2018-08-15

    A new fluorescent probe 6-(2, 4-dinitrophenoxy)-2-naphthonitrile (probe 1) was designed and synthesized for the selective detection of hydrogen sulfide (H 2 S). The addition of H 2 S to a solution of probe 1 resulted in a marked fluorescence turn-on alongside a visual color change from colorless to light yellow. Importantly, this distinct color response indicated that probe 1 could be used as a visual sensor for H 2 S. Moreover, probe 1 was successfully used as a signal tool to determine the H 2 S levels in beer and red wine. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. A fluorescent dipyrrinone oxime for the detection of pesticides and other organophosphates.

    Science.gov (United States)

    Walton, Ian; Davis, Marauo; Munro, Lyndsay; Catalano, Vincent J; Cragg, Peter J; Huggins, Michael T; Wallace, Karl J

    2012-06-01

    An N,N-carbonyl-bridged dipyrrinone oxime has been synthesized and studied as a potential sensor for organophosphates. The molecular sensor underwent a drastic colorimetric response upon formation of the adduct. The pesticide dimethoate was found to produce the biggest spectral response, with a limit of detection equal to 4.0 ppm using UV-visible spectroscopy. Minimal fluorescence "turn on" via a PET mechanism was seen, and molecular modeling studies were used to explain the lower than expected PET response. The X-ray crystal structure of the fluorescent dipyrrinone oxime was also obtained.

  3. Detection of rheumatoid arthritis by evaluation of normalized variances of fluorescence time correlation functions

    Science.gov (United States)

    Dziekan, Thomas; Weissbach, Carmen; Voigt, Jan; Ebert, Bernd; MacDonald, Rainer; Bahner, Malte L.; Mahler, Marianne; Schirner, Michael; Berliner, Michael; Berliner, Birgitt; Osel, Jens; Osel, Ilka

    2011-07-01

    Fluorescence imaging using the dye indocyanine green as a contrast agent was investigated in a prospective clinical study for the detection of rheumatoid arthritis. Normalized variances of correlated time series of fluorescence intensities describing the bolus kinetics of the contrast agent in certain regions of interest were analyzed to differentiate healthy from inflamed finger joints. These values are determined using a robust, parameter-free algorithm. We found that the normalized variance of correlation functions improves the differentiation between healthy joints of volunteers and joints with rheumatoid arthritis of patients by about 10% compared to, e.g., ratios of areas under the curves of raw data.

  4. Portable total reflection X-ray fluorescence spectrometer for nanogram Cr detection limit.

    Science.gov (United States)

    Kunimura, Shinsuke; Kawai, Jun

    2007-03-15

    A portable total reflection X-ray fluorescence spectrometer is presented. The present spectrometer mainly consists of a 1.5-W X-ray tube, a waveguide type slit, a detector, and a sample carrier (a quartz optical flat), and these components are contained in an attache case-type box. Continuum X-rays emitted from the low-power X-ray tube are used for the excitation of the X-ray fluorescence, and the minimum detection limit for Cr is a few nanograms or the level of 1013 atoms/cm2.

  5. Fluorescence from atmospheric aerosol detected by a lidar indicates biogenic particles in the lowermost stratosphere

    Directory of Open Access Journals (Sweden)

    F. Immler

    2005-01-01

    Full Text Available With a lidar system that was installed in Lindenberg/Germany, we observed in June 2003 an extended aerosol layer at 13km altitude in the lowermost stratosphere. This layer created an inelastic backscatter signal that we detected with a water vapour Raman channel, but that was not produced by Raman scattering. Also, we find evidence for inelastic scattering from a smoke plume from a forest fire that we observed in the troposphere. We interpret the unexpected properties of these aerosols as fluorescence induced by the laser beam at organic components of the aerosol particles. Fluorescence from ambient aerosol had not yet been considered detectable by lidar systems. However, organic compounds such as polycyclic aromatic hydrocarbons sticking to the aerosol particles, or bioaerosol such as bacteria, spores or pollen fluoresce when excited with UV-radiation in a way that is detectable by our lidar system. Therefore, we conclude that fluorescence from organic material released by biomass burning creates, inelastic backscatter signals that we measured with our instrument and thus demonstrate a new and powerful way to characterize aerosols by a remote sensing technique. The stratospheric aerosol layer that we have observed in Lindenberg for three consecutive days is likely to be a remnant from Siberian forest fire plumes lifted across the tropopause and transported around the globe.

  6. Nanostructured biosensor for detecting glucose in tear by applying fluorescence resonance energy transfer quenching mechanism.

    Science.gov (United States)

    Chen, Longyi; Tse, Wai Hei; Chen, Yi; McDonald, Matthew W; Melling, James; Zhang, Jin

    2017-05-15

    In this paper, a nanostructured biosensor is developed to detect glucose in tear by using fluorescence resonance energy transfer (FRET) quenching mechanism. The designed FRET pair, including the donor, CdSe/ZnS quantum dots (QDs), and the acceptor, dextran-binding malachite green (MG-dextran), was conjugated to concanavalin A (Con A), an enzyme with specific affinity to glucose. In the presence of glucose, the quenched emission of QDs through the FRET mechanism is restored by displacing the dextran from Con A. To have a dual-modulation sensor for convenient and accurate detection, the nanostructured FRET sensors were assembled onto a patterned ZnO nanorod array deposited on the synthetic silicone hydrogel. Consequently, the concentration of glucose detected by the patterned sensor can be converted to fluorescence spectra with high signal-to-noise ratio and calibrated image pixel value. The photoluminescence intensity of the patterned FRET sensor increases linearly with increasing concentration of glucose from 0.03mmol/L to 3mmol/L, which covers the range of tear glucose levels for both diabetics and healthy subjects. Meanwhile, the calibrated values of pixel intensities of the fluorescence images captured by a handhold fluorescence microscope increases with increasing glucose. Four male Sprague-Dawley rats with different blood glucose concentrations were utilized to demonstrate the quick response of the patterned FRET sensor to 2µL of tear samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Trace Detection of RDX, HMX and PETN Explosives Using a Fluorescence Spot Sensor.

    Science.gov (United States)

    Wang, Chen; Huang, Helin; Bunes, Benjamin R; Wu, Na; Xu, Miao; Yang, Xiaomei; Yu, Li; Zang, Ling

    2016-05-05

    1,3,5-trinitroperhydro-1,3,5-triazine (RDX), octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), and pentaerythritol tetranitrate (PETN), the major components in plastic explosives, pose a significant threat to public safety. A quick, sensitive, and low-cost detection method for these non-volatile explosives is eagerly demanded. Here we present a fluo-spot approach, which can be employed for in situ detection of trace amount of explosives. The sensor molecule is a charge-transfer fluorophore, DCM, which is strongly fluorescent in its pristine state, but non-fluorescent after the quick reaction with NO2· (or NO2(+)) generated from the UV photolysis of RDX, HMX (or PETN). When fabricated within silica gel TLC plate, the fluo-spot sensor features high sensitivity owing to the large surface area and porous structure of the substrate. The sensor reaction mechanism was verified by various experimental characterizations, including chromatography, UV-Vis absorption and fluorescence spectroscopy, MS and (1)H NMR spectrometry. The fluo-spot also demonstrated high selectivity towards RDX, HMX and PETN, as no significant fluorescence quenching was observed for other chemical compounds including common nitro-aromatic explosives and inorganic oxidative compounds. The DCM sensor can also be used as an economical spray kit to directly spot the explosives by naked eyes, implying great potential for quick, low-cost trace explosives detection.

  8. Real-time detection of an airborne microorganism using inertial impaction and mini-fluorescent microscopy.

    Science.gov (United States)

    Kang, Joon Sang; Lee, Kang Soo; Kim, Sang Soo; Bae, Gwi-Nam; Jung, Jae Hee

    2014-01-07

    To achieve successful real-time detection of airborne pathogenic microorganisms, the problem must be considered in terms of their physical size and biological characteristics. We developed an airborne microorganism detection chip to realize the detection of microorganisms, ensuring compactness, sensitivity, cost-efficiency, and portability, using three key components: an inertial impaction system, a cartridge-type impaction plate, and a mini-fluorescent microscope. The inertial impaction system was used to separate microorganisms in terms of their aerodynamic particle size, and was fabricated with three impaction stages. Numerical analysis was performed to design the system; the calculated cutoff diameter at each impaction stage was 2.02 (first stage), 0.88 (second stage), and 0.54 μm (third stage). The measured cutoff diameters were 2.24, 0.91, and 0.49 μm, respectively. A cartridge-type impaction plate was used, composed of molded polydimethylsiloxane (PDMS) and an actual impaction region made of a SYBR green I dye-stained agar plate. A mini-fluorescent microscope was used to distinguish microbes from non-biological particles. Images of the microorganisms deposited at the impaction zone were obtained via mini-fluorescent microscopy, and fluorescent intensities of the images were calculated using in-house image-processing software. The results showed that the developed system successfully identified aerosolized biological particles from non-biological particles in real time.

  9. Supramolecular assembly affording a ratiometric two-photon fluorescent nanoprobe for quantitative detection and bioimaging.

    Science.gov (United States)

    Wang, Peng; Zhang, Cheng; Liu, Hong-Wen; Xiong, Mengyi; Yin, Sheng-Yan; Yang, Yue; Hu, Xiao-Xiao; Yin, Xia; Zhang, Xiao-Bing; Tan, Weihong

    2017-12-01

    Fluorescence quantitative analyses for vital biomolecules are in great demand in biomedical science owing to their unique detection advantages with rapid, sensitive, non-damaging and specific identification. However, available fluorescence strategies for quantitative detection are usually hard to design and achieve. Inspired by supramolecular chemistry, a two-photon-excited fluorescent supramolecular nanoplatform ( TPSNP ) was designed for quantitative analysis with three parts: host molecules (β-CD polymers), a guest fluorophore of sensing probes (Np-Ad) and a guest internal reference (NpRh-Ad). In this strategy, the TPSNP possesses the merits of (i) improved water-solubility and biocompatibility; (ii) increased tissue penetration depth for bioimaging by two-photon excitation; (iii) quantitative and tunable assembly of functional guest molecules to obtain optimized detection conditions; (iv) a common approach to avoid the limitation of complicated design by adjustment of sensing probes; and (v) accurate quantitative analysis by virtue of reference molecules. As a proof-of-concept, we utilized the two-photon fluorescent probe NHS-Ad-based TPSNP-1 to realize accurate quantitative analysis of hydrogen sulfide (H 2 S), with high sensitivity and good selectivity in live cells, deep tissues and ex vivo -dissected organs, suggesting that the TPSNP is an ideal quantitative indicator for clinical samples. What's more, TPSNP will pave the way for designing and preparing advanced supramolecular sensors for biosensing and biomedicine.

  10. Modular fluorescence complementation sensors for live cell detection of epigenetic signals at endogenous genomic sites.

    Science.gov (United States)

    Lungu, Cristiana; Pinter, Sabine; Broche, Julian; Rathert, Philipp; Jeltsch, Albert

    2017-09-21

    Investigation of the fundamental role of epigenetic processes requires methods for the locus-specific detection of epigenetic modifications in living cells. Here, we address this urgent demand by developing four modular fluorescence complementation-based epigenetic biosensors for live-cell microscopy applications. These tools combine engineered DNA-binding proteins with domains recognizing defined epigenetic marks, both fused to non-fluorescent fragments of a fluorescent protein. The presence of the epigenetic mark at the target DNA sequence leads to the reconstitution of a functional fluorophore. With this approach, we could for the first time directly detect DNA methylation and histone 3 lysine 9 trimethylation at endogenous genomic sites in live cells and follow dynamic changes in these marks upon drug treatment, induction of epigenetic enzymes and during the cell cycle. We anticipate that this versatile technology will improve our understanding of how specific epigenetic signatures are set, erased and maintained during embryonic development or disease onset.Tools for imaging epigenetic modifications can shed light on the regulation of epigenetic processes. Here, the authors present a fluorescence complementation approach for detection of DNA and histone methylation at endogenous genomic sites allowing following of dynamic changes of these marks by live-cell microscopy.

  11. Detection of biological warfare agents using ultra violet-laser induced fluorescence LIDAR.

    Science.gov (United States)

    Joshi, Deepti; Kumar, Deepak; Maini, Anil K; Sharma, Ramesh C

    2013-08-01

    This review has been written to highlight the threat of biological warfare agents, their types and detection. Bacterial biological agent Bacillus anthracis (bacteria causing the disease anthrax) which is most likely to be employed in biological warfare is being discussed in detail. Standoff detection of biological warfare agents in aerosol form using Ultra violet-Laser Induced Fluorescence (UV-LIF) spectroscopy method has been studied. Range-resolved detection and identification of biological aerosols by both nano-second and non-linear femto-second LIDAR is also discussed. Calculated received fluorescence signal for a cloud of typical biological agent Bacillus globigii (Simulants of B. anthracis) at a location of ~5.0 km at different concentrations in presence of solar background radiation has been described. Overview of current research efforts in internationally available working UV-LIF LIDAR systems are also mentioned briefly. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Quantitation of CRM197 using imaged capillary isoelectric focusing with fluorescence detection and capillary Western.

    Science.gov (United States)

    Loughney, John W; Ha, Sha; Rustandi, Richard R

    2017-10-01

    Maurice is a new instrument that can perform imaged capillary isoelectric focusing (icIEF). The standard detection for icIEF is UV absorbance at 280 nm, which limits its application to high protein concentration samples and non-complex samples. Here we describe an icIEF instrument with fluorescence detection. We demonstrate the advantage of using either icIEF with fluorescence detection or quantitative Western Blot to measure diphtheria toxin mutant CRM197 protein titer in crude cell lysates and purified samples. These two techniques have great potentials to become standard methods to analyze protein titers in crude cell lysate or other complex samples types. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Protein A Detection Based on Quantum Dots-Antibody Bioprobe Using Fluorescence Coupled Capillary Electrophoresis

    Directory of Open Access Journals (Sweden)

    Lin Qiu

    2014-01-01

    Full Text Available In this report, fluorescence detection coupled capillary electrophoresis (CE-FL was used to detect Protein A. Antibody was first labeled with Cy5 and then mixed with quantum dots (QDs to form QDs-antibody bioprobe. Further, we observed fluorescence resonance energy transfer (FRET from QDs donor to Cy5 acceptor. The bioprobe was formed and brought QDs and Cy5 close enough to allow FRET to occur. After adding protein A, the FRET system was broken and caused the FRET signal to decrease. Thus, a new method for the determination of protein A was proposed based on the FRET signal changes. This study provides a new trail of thought for the detection of protein.

  14. Rapid fluorescence detection of pathogenic bacteria using magnetic enrichment technique combined with magnetophoretic chromatography.

    Science.gov (United States)

    Che, Yulan; Xu, Yi; Wang, Renjie; Chen, Li

    2017-08-01

    A rapid and sensitive analytical method was developed to detect pathogenic bacteria which combined magnetic enrichment, fluorescence labeling with polyethylene glycol (PEG) magnetophoretic chromatography. As pathogenic bacteria usually exist in complex matrixes at low concentration, an efficient enrichment is essential for diagnosis. In order to capture series types of pathogenic bacteria in samples, amino-modified magnetic nanoparticles (Fe 3 O 4 @SiO 2 -NH 2 ) were prepared for efficient enrichment by the electrostatic interaction with pathogenic bacteria. It was shown that the capture efficiency reached up to 95.4% for Escherichia coli (E. coli). Furthermore, quantitative analysis of the bacteria was achieved by using acridine orange (AO) as a fluorescence probe for the captured E. coli due to its ability of staining series types of bacteria and rapid labeling. In order to remove the free magnetic nanoparticles and redundant fluorescent reagent, the labeled suspension was poured into a PEG separation column and was separated by applying an external magnetic field. The presence of 100 cfu mL -1 E. coli could be detected for semi-quantitative analysis by observing the separation column with the naked eye, and the concentration could be further evaluated by fluorescence detection. All the above processes were finished within 80 min. It was demonstrated that a good linear relationship existed between the fluorescence intensity and the concentration of E. coli ranging from 10 2 to 10 6  cfu mL -1 , with a detection limit of 100 cfu mL -1 when E. coli acted as target bacteria. The recovery rate of E. coli was 93.6∼102.0% in tap water and cooked meat samples, and the RSD was lower than 7% (n = 6); the result coincided with the conventional plate count method. Graphical abstract ᅟ.

  15. The use of fluorescent intrabodies to detect endogenous gankyrin in living cancer cells

    International Nuclear Information System (INIS)

    Rinaldi, Anne-Sophie; Freund, Guillaume; Desplancq, Dominique; Sibler, Annie-Paule; Baltzinger, Mireille; Rochel, Natacha; Mély, Yves; Didier, Pascal; Weiss, Etienne

    2013-01-01

    Expression of antibody fragments in mammalian cells (intrabodies) is used to probe the target protein or interfere with its biological function. We previously described the in vitro characterisation of a single-chain Fv (scFv) antibody fragment (F5) isolated from an intrabody library that binds to the oncoprotein gankyrin (GK) in solution. Here, we have isolated several other scFvs that interact with GK in the presence of F5 and tested whether they allow, when fused to fluorescent proteins, to detect by FRET endogenous GK in living cells. The binding of pairs of scFvs to GK was analysed by gel filtration and the ability of each scFv to mediate nuclear import/export of GK was determined. Binding between scFv-EGFP and RFP-labelled GK in living cells was detected by fluorescence lifetime imaging microscopy (FLIM). After co-transfection of two scFvs fused to EGFP and RFP, respectively, which form a tri-molecular complex with GK in vitro, FRET signal was measured. This system allowed us to observe that GK is monomeric and distributed throughout the cytoplasm and nucleus of several cancer cell lines. Our results show that pairs of fluorescently labelled intrabodies can be monitored by FLIM–FRET microscopy and that this technique allows the detection of lowly expressed endogenous proteins in single living cells. Highlights: ► Endogenous GK in living cells was targeted with pairs of fluorescently-tagged scFvs. ► Tri-molecular complexes containing two scFvs and one molecule GK were formed. ► GK was detected using fluorescence lifetime-based FRET imaging. ► GK is monomeric and homogeneously distributed in several cancer cell lines. ► This technique may have many applications in live-cell imaging of endogenous proteins

  16. The use of fluorescent intrabodies to detect endogenous gankyrin in living cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Rinaldi, Anne-Sophie; Freund, Guillaume; Desplancq, Dominique; Sibler, Annie-Paule; Baltzinger, Mireille [Ecole Supérieure de Biotechnologie de Strasbourg, UMR 7242, CNRS/Université de Strasbourg, boulevard Sébastien Brant, 67412 Illkirch (France); Rochel, Natacha [Institut de Génétique et de Biologie Moléculaire et Cellulaire, UMR 7104, CNRS/INSERM/Université de Strasbourg, rue Laurent Fries, 67404 Illkirch (France); Mély, Yves; Didier, Pascal [Faculté de Pharmacie, UMR 7213, CNRS/Université de Strasbourg, route du Rhin, 67401 Illkirch (France); Weiss, Etienne, E-mail: eweiss@unistra.fr [Ecole Supérieure de Biotechnologie de Strasbourg, UMR 7242, CNRS/Université de Strasbourg, boulevard Sébastien Brant, 67412 Illkirch (France)

    2013-04-01

    Expression of antibody fragments in mammalian cells (intrabodies) is used to probe the target protein or interfere with its biological function. We previously described the in vitro characterisation of a single-chain Fv (scFv) antibody fragment (F5) isolated from an intrabody library that binds to the oncoprotein gankyrin (GK) in solution. Here, we have isolated several other scFvs that interact with GK in the presence of F5 and tested whether they allow, when fused to fluorescent proteins, to detect by FRET endogenous GK in living cells. The binding of pairs of scFvs to GK was analysed by gel filtration and the ability of each scFv to mediate nuclear import/export of GK was determined. Binding between scFv-EGFP and RFP-labelled GK in living cells was detected by fluorescence lifetime imaging microscopy (FLIM). After co-transfection of two scFvs fused to EGFP and RFP, respectively, which form a tri-molecular complex with GK in vitro, FRET signal was measured. This system allowed us to observe that GK is monomeric and distributed throughout the cytoplasm and nucleus of several cancer cell lines. Our results show that pairs of fluorescently labelled intrabodies can be monitored by FLIM–FRET microscopy and that this technique allows the detection of lowly expressed endogenous proteins in single living cells. Highlights: ► Endogenous GK in living cells was targeted with pairs of fluorescently-tagged scFvs. ► Tri-molecular complexes containing two scFvs and one molecule GK were formed. ► GK was detected using fluorescence lifetime-based FRET imaging. ► GK is monomeric and homogeneously distributed in several cancer cell lines. ► This technique may have many applications in live-cell imaging of endogenous proteins.

  17. Ratio-metric sensor to detect riboflavin via fluorescence resonance energy transfer with ultrahigh sensitivity

    Science.gov (United States)

    Wang, Jilong; Su, Siheng; Wei, Junhua; Bahgi, Roya; Hope-Weeks, Louisa; Qiu, Jingjing; Wang, Shiren

    2015-08-01

    In this paper, a novel fluorescence resonance energy transfer (FRET) ration-metric fluorescent probe based on heteroatom N, S doped carbon dots (N, S-CDs) was developed to determine riboflavin in aqueous solutions. The ratio of two emission intensities at different wavelengths is applied to determine the concentration of riboflavin (RF). This method is more effective in reducing the background interference and fluctuation of diverse conditions. Therefore, this probe obtains high sensitivity with a low limit of detection (LOD) of 1.9 nM (0.7 ng/ml) which is in the highest level of all riboflavin detection approaches and higher than single wavelength intensity detection (1.9 μM). In addition, this sensor has a high selectivity of detecting riboflavin in deionized water (pH=7) with other biochemical like amino acids. Moreover, riboflavin in aqueous solution is very sensitive to sunlight and can be degraded to lumiflavin, which is toxic. Because the N, S doped carbon dots cannot serve as an energy donor for N, S doped carbon dots and lumiflavin system, this system makes it easy to determine whether the riboflavin is degraded or not, which is first to be reported. This platform may provide possibilities to build a new and facile fluorescence resonance energy transfer based sensor to detect analytes and metamorphous analytes in aqueous solution.

  18. Biosynthesis of CdS nanoparticles: A fluorescent sensor for sulfate-reducing bacteria detection.

    Science.gov (United States)

    Qi, Peng; Zhang, Dun; Zeng, Yan; Wan, Yi

    2016-01-15

    CdS nanoparticles were synthesized with an environmentally friendly method by taking advantage of the characteristic metabolic process of sulfate-reducing bacteria (SRB), and used as fluorescence labels for SRB detection. The presence of CdS nanoparticles was observed within and immediately surrounded bacterial cells, indicating CdS nanoparticles were synthesized both intracellularly and extracellularly. Moreover, fluorescent properties of microbial synthesized CdS nanoparticles were evaluated for SRB detection, and a linear relationship between fluorescence intensity and the logarithm of bacterial concentration was obtained in the range of from 1.0×10(2) to 1.0×10(7)cfu mL(-1). The proposed SRB detection method avoided the use of biological bio-recognition elements which are easy to lose their specific recognizing abilities, and the bacterial detection time was greatly shortened compared with the widely used MPN method which would take up to 15 days to accomplish the detection process. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Direct fluorescence detection of VirE2 secretion by Agrobacterium tumefaciens.

    Science.gov (United States)

    Yaakov, Noga; Barak, Yoav; Pereman, Idan; Christie, Peter J; Elbaum, Michael

    2017-01-01

    VirE2 is a ssDNA binding protein essential for virulence in Agrobacterium tumefaciens. A tetracysteine mutant (VirE2-TC) was prepared for in vitro and in vivo fluorescence imaging based on the ReAsH reagent. VirE2-TC was found to be biochemically active as it binds both ssDNA and the acidic secretion chaperone VirE1. It was also biologically functional in complementing virE2 null strains transforming Arabidopsis thaliana roots and Nicotiana tabacum leaves. In vitro experiments demonstrated a two-color fluorescent complex using VirE2-TC/ReAsH and Alexa Fluor 488 labeled ssDNA. In vivo, fluorescent VirE2-TC/ReAsH was detected in bacteria and in plant cells at time frames relevant to transformation.

  20. Direct fluorescence detection of VirE2 secretion by Agrobacterium tumefaciens

    Science.gov (United States)

    Yaakov, Noga; Barak, Yoav; Pereman, Idan; Christie, Peter J.; Elbaum, Michael

    2017-01-01

    VirE2 is a ssDNA binding protein essential for virulence in Agrobacterium tumefaciens. A tetracysteine mutant (VirE2-TC) was prepared for in vitro and in vivo fluorescence imaging based on the ReAsH reagent. VirE2-TC was found to be biochemically active as it binds both ssDNA and the acidic secretion chaperone VirE1. It was also biologically functional in complementing virE2 null strains transforming Arabidopsis thaliana roots and Nicotiana tabacum leaves. In vitro experiments demonstrated a two-color fluorescent complex using VirE2-TC/ReAsH and Alexa Fluor 488 labeled ssDNA. In vivo, fluorescent VirE2-TC/ReAsH was detected in bacteria and in plant cells at time frames relevant to transformation. PMID:28403156

  1. A Fluorescent Probe for Sensitive Detection of Hydrazine and Its Application in Red Wine and Water.

    Science.gov (United States)

    Wang, Jialin; Wang, Hao; Yang, Shaoxiang; Tian, Hongyu; Liu, Yongguo; Hao, Yanfeng; Zhang, Jie; Sun, Baoguo

    2018-01-01

    A fluorescent probe, 7-(diethylamino)-2-oxo-2H-chromene-4-carbaldehyde (probe 1), was designed and synthesized for the sensitive detection of hydrazine. The addition of N 2 H 4 caused the fluorescence intensity of probe 1 to decrease. The probe's fluorescence was turn-off after adding N 2 H 4 , which could be observed under UV light at 365 nm. Moreover, once treated with different concentrations N 2 H 4 solutions, the solution color change could be distinguished, which indicates that probe 1 could be used as a visual sensor for hydrazine. Moreover, probe 1 can be used as a signal tool to determine hydrazine levels in solutions, such as red wine and water.

  2. Detection of potassium deficiency on palm oil tree (Elaeis guineensis (jacq)) by laser induced fluorescence

    International Nuclear Information System (INIS)

    Diomande, K.; Konate, A.; Krou Adjo, V.; Soro, A.; Ebby, N.; Ballo, K.

    1998-02-01

    The potassium is the main nutrient element which plays a significant role on oil palm tree (Elaeis guineensis (jacq)) production and its resistance to the dry season. One can observe 30% decrease of the production in case of potassium deficiency. The potassium nutrition control of an oil palm tree field is a very important activity and leads to the fertilization policy. The Laser Induced Fluorescence (L.I.F.) is a fast and simple method compared to the classical one, ''Diagnostic Foliaire'', usually used in agronomy. We used the L.I.F. method to detect the oil palm tree stress caused by potassium deficiency, analysing the fluorescence spectrum of the chlorophyll a. We proved that the intensity ratio of the fluorescence spectrum R=F690/F73S is superior to 0.5 when the tree is under stress and its value is around 0.4 in case of intact tree. (author)

  3. Rapidly Responsive and Highly Selective Fluorescent Probe for Bisulfite Detection in Food.

    Science.gov (United States)

    Wang, Jialin; Hao, Yanfeng; Wang, Hao; Yang, Shaoxiang; Tian, Hongyu; Sun, Baoguo; Liu, Yongguo

    2017-04-05

    The new fluorescent probe 4-hydroxy-3-((2E,4E)-5-phenylpenta-2,4-dienoyl)-2H-chromen-2-one (probe 1) was designed and synthesized for selective detection of sulfite. The fluorescence intensity of the probe was decreased only in the presence of HSO 3 - ; all other anions assessed resulted in an increased fluorescence response. Hence, probe 1 acts as a highly selective sensor for HSO 3 - . This sulfite sensitivity can also be readily monitored visually, as once treated with sulfite the solution shows a marked color change from yellow to colorless. Moreover, probe 1 can be conveniently used as a signal tool to determine the HSO 3 - levels in various sugar samples.

  4. Measurement of fluorescent probes concentration ratio in the cerebrospinal fluid for early detection of Alzheimer's disease

    Science.gov (United States)

    Harbater, Osnat; Gannot, Israel

    2014-03-01

    The pathogenic process of Alzheimer's Disease (AD), characterized by amyloid plaques and neurofibrillary tangles in the brain, begins years before the clinical diagnosis. Here, we suggest a novel method which may detect AD up to nine years earlier than current exams, minimally invasive, with minimal risk, pain and side effects. The method is based on previous reports which relate the concentrations of biomarkers in the Cerebrospinal Fluid (CSF) (Aβ and Tau proteins) to the future development of AD in mild cognitive impairment patients. Our method, which uses fluorescence measurements of the relative concentrations of the CSF biomarkers, replaces the lumbar puncture process required for CSF drawing. The process uses a miniature needle coupled trough an optical fiber to a laser source and a detector. The laser radiation excites fluorescent probes which were prior injected and bond to the CSF biomarkers. Using the ratio between the fluorescence intensities emitted from the two biomarkers, which is correlated to their concentration ratio, the patient's risk of developing AD is estimated. A theoretical model was developed and validated using Monte Carlo simulations, demonstrating the relation between fluorescence emission and biomarker concentration. The method was tested using multi-layered tissue phantoms simulating the epidural fat, the CSF in the sub-arachnoid space and the bone. These phantoms were prepared with different scattering and absorption coefficients, thicknesses and fluorescence concentrations in order to simulate variations in human anatomy and in the needle location. The theoretical and in-vitro results are compared and the method's accuracy is discussed.

  5. Studies of benzothiazole and benzoselenazole squaraines as fluorescent probes for albumins detection.

    Science.gov (United States)

    Volkova, Kateryna D; Kovalska, Vladyslava B; Losytskyy, Mykhaylo Yu; Bento, Artur; Reis, Lucinda V; Santos, Paulo F; Almeida, Paulo; Yarmoluk, Sergiy M

    2008-09-01

    Series of squaraine benzothiazole and benzoselenazole dyes were studied as possible fluorescent probes for the detection of proteins, particularly albumins. It was shown that majority of the studied squaraines give significant fluorescent response on the human serum albumin (HSA) and bovine serum albumin presence. For squaraine dyes with N-hexyl pendent groups (P-1, P-2, P-3, P-5) about 100-540-fold fluorescence intensity increase upon albumins addition was observed. At the same time in presence of other proteins, namely insulin, avidin from hen egg white, immunoglobulin G (IgG), carbonic anhydrase fluorescence enhancement values were considerably lower -up to 43 times in IgG presence. It was noted that generally, squaraines with long N-hexyl pendent groups demonstrate higher emission increase values upon proteins addition comparing with their analogues with short N-ethyl tails. It was shown that fluorescence intensity enhancement for benzothiazole squaraine dye P-3, relates linearly to the HSA concentration over the wide range-from 0.2 to 500 microg/ml. Together with noticeable selectivity of this dye to albumins, existence of wide dynamic range gives possibility to propose P-3 dye as probe for HSA quantification.

  6. Highly sensitive rapid fluorescence detection of protein residues on surgical instruments

    International Nuclear Information System (INIS)

    Kovalev, Valeri I; Bartona, James S; Richardson, Patricia R; Jones, Anita C

    2006-01-01

    There is a risk of contamination of surgical instruments by infectious protein residues, in particular, prions which are the agents for Creutzfeldt-Jakob Disease in humans. They are exceptionally resistant to conventional sterilization, therefore it is important to detect their presence as contaminants so that alternative cleaning procedures can be applied. We describe the development of an optimized detection system for fluorescently labelled protein, suitable for in-hospital use. We show that under optimum conditions the technique can detect ∼10 attomole/cm 2 with a scan speed of ∼3-10 cm 2 /s of the test instrument's surface. A theoretical analysis and experimental measurements will be discussed

  7. Detection limits of 405 nm and 633 nm excited PpIX fluorescence for brain tumor detection during stereotactic biopsy

    Science.gov (United States)

    Markwardt, Niklas; Götz, Marcus; Haj-Hosseini, Neda; Hollnburger, Bastian; Sroka, Ronald; Stepp, Herbert; Zelenkov, Petr; Rühm, Adrian

    2016-04-01

    5-aminolevulinic-acid-(5-ALA)-induced protoporphyrin IX (PpIX) fluorescence may be used to improve stereotactic brain tumor biopsies. In this study, the sensitivity of PpIX-based tumor detection has been investigated for two potential excitation wavelengths (405 nm, 633 nm). Using a 200 μm fiber in contact with semi-infinite optical phantoms containing ink and Lipovenös, PpIX detection limits of 4.0 nM and 200 nM (relating to 1 mW excitation power) were determined for 405 nm and 633 nm excitation, respectively. Hence, typical PpIX concentrations in glioblastomas of a few μM should be well detectable with both wavelengths. Additionally, blood layers of selected thicknesses were placed between fiber and phantom. Red excitation was shown to be considerably less affected by blood interference: A 50 μm blood layer, for instance, blocked the 405- nm-excited fluorescence completely, but reduced the 633-nm-excited signal by less than 50%. Ray tracing simulations demonstrated that - without blood layer - the sensitivity advantage of 405 nm rises for decreasing fluorescent volume from 50-fold to a maximum of 100-fold. However, at a tumor volume of 1 mm3, which is a typical biopsy sample size, the 633-nm-excited fluorescence signal is only reduced by about 10%. Further simulations revealed that with increasing fiber-tumor distance, the signal drops faster for 405 nm. This reduces the risk of detecting tumor tissue outside the needle's coverage, but diminishes the overlap between optically and mechanically sampled volumes. While 405 nm generally offers a higher sensitivity, 633 nm is more sensitive to distant tumors and considerably superior in case of blood-covered tumor tissue.

  8. Automatic segmentation of lesions for the computer-assisted detection in fluorescence urology

    Science.gov (United States)

    Kage, Andreas; Legal, Wolfgang; Kelm, Peter; Simon, Jörg; Bergen, Tobias; Münzenmayer, Christian; Benz, Michaela

    2012-03-01

    Bladder cancer is one of the most common cancers in the western world. The diagnosis in Germany is based on the visual inspection of the bladder. This inspection performed with a cystoscope is a challenging task as some kinds of abnormal tissues do not differ much in their appearance from their surrounding healthy tissue. Fluorescence Cystoscopy has the potential to increase the detection rate. A liquid marker introduced into the bladder in advance of the inspection is concentrated in areas with high metabolism. Thus these areas appear as bright "glowing". Unfortunately, the fluorescence image contains besides the glowing of the suspicious lesions no more further visual information like for example the appearance of the blood vessels. A visual judgment of the lesion as well as a precise treatment has to be done using white light illumination. Thereby, the spatial information of the lesion provided by the fluorescence image has to be guessed by the clinical expert. This leads to a time consuming procedure due to many switches between the modalities and increases the risk of mistreatment. We introduce an automatic approach, which detects and segments any suspicious lesion in the fluorescence image automatically once the image was classified as a fluorescence image. The area of the contour of the detected lesion is transferred to the corresponding white light image and provide the clinical expert the spatial information of the lesion. The advantage of this approach is, that the clinical expert gets the spatial and the visual information of the lesion together in one image. This can save time and decrease the risk of an incomplete removal of a malign lesion.

  9. Fluorescent cadmium sulfide nanoparticles for selective and sensitive detection of toxic pesticides in aqueous medium

    International Nuclear Information System (INIS)

    Walia, Shanka; Acharya, Amitabha

    2014-01-01

    The detection of pesticide residues in ground water, food, or soil samples is extremely important. The currently available laboratory techniques have several drawbacks and needs to be replaced. Fluorescent chemosensors for pesticide detection were reported in the literature, with few reports published on quantum dot-based pesticide sensors, but none of these were focused toward differentiating organophosphorus and organochlorine pesticides specifically. In this respect, glutathione-coated CdS nanoparticles were synthesized and characterized. The TEM studies of the nanoparticles suggested mostly monodispersed spherical particles, with size in the range of 11.5±1 nm. The prepared fluorescent nanoparticles were found to selectively recognize organochlorine pesticide dicofol among all the other pesticides studied, by increasing the fluorescence intensity of the nanoparticles ∼ 2.5 times. Similar studies carried out with organophosphorous pesticide dimethoate did not result any change in the fluorescence intensity of the nanoparticles. Further studies carried out with commercially available pesticide solutions, also confirmed similar results. The TEM, SEM, and DLS studies suggested aggregation of the nanoparticles in the presence of dicofol. Control experiments suggested possible role of both amine and carboxylic acid functional groups of glutathione in the recognition of dicofol. The limit of detection of dicofol was found to be ∼ 55±11 ppb.Graphical AbstractGlutathione-coated CdS nanoparticles selectively recognize organochlorine pesticide dicofol among all the other pesticides studied, by increasing the fluorescence intensity of the nanoparticles. The TEM, SEM, and DLS studies suggested aggregation of the nanoparticles in the presence of dicofol

  10. In vitro evaluation of laser fluorescence devices for caries detection through stereomicroscopic imaging.

    Science.gov (United States)

    Oancea, Roxana; Podariu, Angela Codruţa; Vasile, Liliana; Sava-Roşianu, Ruxandra; Folescu, Roxana

    2013-01-01

    The aims of this study were to determine the diagnostic accuracy and reproducibility of the laser fluorescence device (LF), and the relationship between laser fluorescence readings taken at the entrance of the fissure, ICDAS visual examination caries detection system and the histological depth of the lesion. Two hundred and forty teeth (122 human third molars and 118 bicuspids) were selected from 62 patients enrolled in the study. Visual and LF examinations (Diagnodent, Kavo, Biberach, Germany) of the occlusal surfaces were performed in vivo. After tooth extraction, histological sections were evaluated by stereomicroscopy in vitro. Statistical analysis was performed using multiple statistical methods (SPSS ver. 17). Intra-examiner reproducibility for the LF measurements was excellent: intra-class-correlation coefficient (ICC) for LF was 0.957. Kappa values for each examiner's reproducibility were 0.74-0.82. The diagnostic performance of the LF device gave a good overall diagnostic accuracy according to ICDAS II codes and histological values as indicated by the area under the ROC curve of 0.707 and 0.709 respectively. The results of the study showed acceptable diagnostic accuracy for the laser fluorescence device. This supports the view that dentists can be site specific in applying fluorescence-based devices to multiple discrete sites within the same surface. In conclusion, these diagnostic methods have different characteristics, indications and limitations for use. In order to detect caries on occlusal surfaces thoroughly, a combination of methods would be the best practice moderated by clinical knowledge and experience.

  11. Quaternized magnetic nanoparticles-fluorescent polymer system for detection and identification of bacteria.

    Science.gov (United States)

    Wan, Yi; Sun, Yan; Qi, Peng; Wang, Peng; Zhang, Dun

    2014-05-15

    Nanomaterial-based 'chemical nose' sensor with sufficient sensing specificity is a useful analytical tool for the detection of toxicologically important substances in complicated biological systems. A sensor array containing three quaternized magnetic nanoparticles (q-MNPs)-fluorescent polymer systems has been designed to identify and quantify bacteria. The bacterial cell membranes disrupt the q-MNP-fluorescent polymer, generating unique fluorescence response array. The response intensity of the array is dependent on the level of displacement determined by the relative q-MNP-fluorescent polymer binding strength and bacteria cells-MNP interaction. These characteristic responses show a highly repeatable bacteria cells and can be differentiated by linear discriminant analysis (LDA). Based on the array response matrix from LDA, our approach has been used to measure bacteria with an accuracy of 87.5% for 10(7) cfu mL(-1) within 20 min. Combined with UV-vis measurement, the method can be successfully performed to identify and detect eight different pathogen samples with an accuracy of 96.8%. The measurement system has a potential for further applications and provides a facile and simple method for the rapid analysis of protein, DNA, and pathogens. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. "Fluorescent glycogen" formation with sensibility for in vivo and in vitro detection.

    Science.gov (United States)

    Louzao, M Carmen; Espiña, Begoña; Vieytes, Mercedes R; Vega, Felix V; Rubiolo, Juan A; Baba, Otto; Terashima, Tatsuo; Botana, Luis M

    2008-08-01

    There are presently many methods of detecting complex carbohydrates, and particularly glycogen. However most of them require radioisotopes or destruction of the tissue and hydrolysis of glycogen to glucose. Here we present a new method based on the incorporation of 2-NBDG (2-{N-[7-nitrobenz-2-oxa-1, 3-diazol 4-yl] amino}-2-deoxyglucose), a D-glucose fluorescent derivative, into glycogen. Two kinds of approaches were carried out by using Clone 9 rat hepatocytes as a cellular model; (1) Incubation of cell lysates with 2-NBDG, carbohydrate precipitation in filters and measurement of fluorescence in a microplate reader (2) Incubation of living hepatocytes with 2-NBDG and recording of fluorescence images by confocal microscopy. 2-NBDG labeled glycogen in both approaches. We confirmed this fact by comparison to the labeling obtained with a specific monoclonal anti-glycogen antibody. Also drugs that trigger glycogen synthesis or degradation induced an increase or decrease of fluorescence, respectively. This is a simple but efficient method of detecting glycogen with 2-NBDG. It could be used to record changes in glycogen stores in living cells and cell-free systems and opens the prospect of understanding the role of this important energy reserve under various physiological and pathophysiological conditions.

  13. Fluorescent nanoscale detection of biotin-streptavidin interaction using near-field scanning optical microscopy

    International Nuclear Information System (INIS)

    Park, Hyun Kyu; Chung, Bong Hyun; Gokarna, Anisha; Hulme, John P; Park, Hyun Gyu

    2008-01-01

    We describe a nanoscale strategy for detecting biotin-streptavidin binding using near-field scanning optical microscopy (NSOM) that exploits the fluorescence properties of single polydiacetylene (PDA) liposomes. NSOM is more useful to observe nanomaterials having optical properties with the help of topological information. We synthesized amine-terminated 10,12-pentacosadiynoic acid (PCDA) monomer (PCDA-NH 2 ) and used this derivatized monomer to prepare PCDA liposomes. PCDA-NH 2 liposomes were immobilized on an aldehyde-functionalized glass surface followed by photopolymerization by using a 254 nm light source. To measure the biotin-streptavidin binding, we conjugated photoactivatable biotin to immobilized PCDA-NH 2 liposomes by UV irradiation (365 nm) and subsequently allowed them to interact with streptavidin. We analyzed the fluorescence using a fluorescence scanner and observed single liposomes using NSOM. The average height and NSOM signal observed in a single liposome after binding were ∼31.3 to 8.5 ± 0.5 nm and 0.37 to 0.16 ± 0.6 kHz, respectively. This approach, which has the advantage of not requiring a fluorescent label, could prove highly beneficial for single molecule detection technology

  14. Detection of polycyclic aromatic hydrocarbons (PAHs) in Medicago sativa L. by fluorescence microscopy.

    Science.gov (United States)

    Alves, Wilber S; Manoel, Evelin A; Santos, Noemi S; Nunes, Rosane O; Domiciano, Giselli C; Soares, Marcia R

    2017-04-01

    Green technologies, such as phytoremediation, are effective for removing organic pollutants derived from oil and oil products, including polycyclic aromatic hydrocarbons (PAHs). Given the increasing popularity of these sustainable remediation techniques, methods based on fluorescence microscopy and multiphoton microscopy for the environmental monitoring of such pollutants have emerged in recent decades as effective tools for phytoremediation studies aimed at understanding the fate of these contaminants in plants. However, little is known about the cellular and molecular mechanisms involved in PAH uptake, responses and degradation by plants. Thus, the present study aimed to detect the location of pyrene, anthracene and phenanthrene using fluorescence microscopy techniques in shoots and roots of Medicago sativa L. (alfalfa) plants grown in artificially contaminated soil (150ppm PAHs) for 40days. Leaflet and root samples were then collected and observed under a fluorescence microscope to detect the presence of PAHs in various tissues. One important finding of the present study was intense fluorescence in the glandular secreting trichomes (GSTs) of plants grown in contaminated soil. These trichomes, with a previously unknown function, may be sites of PAH conjugation and degradation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Fluorescent sensors for selective detection of thiols: expanding the intramolecular displacement based mechanism to new chromophores.

    Science.gov (United States)

    Niu, Li-Ya; Zheng, Hai-Rong; Chen, Yu-Zhe; Wu, Li-Zhu; Tung, Chen-Ho; Yang, Qing-Zheng

    2014-03-21

    Biological thiols, including cysteine (Cys), homocystein (Hcy) and glutathione (GSH), play crucial roles in maintaining the appropriate redox status of biological systems. An abnormal level of biothiols is associated with different diseases, therefore, the discrimination between them is of great importance. Herein, we present two fluorescent sensors for selective detection of biothiols based on our recently reported intramolecular displacement mechanism. We expanded this mechanism to commercially available chromophores, 4-chloro-7-nitro-2,1,3-benzoxadiazole (NBD-Cl) and heptamethine cyanine dye IR-780. The sensors operate by undergoing displacement of chloride by thiolate. The amino groups of Cys/Hcy further replace the thiolate to form amino-substituted products, which exhibit dramatically different photophysical properties compared to sulfur-substituted products from the reaction with GSH. NBD-Cl is highly selective towards Cys/Hcy and exhibits significant fluorescence enhancement. IR-780 showed a variation in its fluorescence ratio towards Cys over other thiols. Both of the sensors can be used for live-cell imaging of Cys. The wide applicability of the mechanism may provide a powerful tool for developing novel fluorescent sensors for selective detection of biothiols.

  16. Image overlay solution based on threshold detection for a compact near infrared fluorescence goggle system.

    Science.gov (United States)

    Gao, Shengkui; Mondal, Suman B; Zhu, Nan; Liang, RongGuang; Achilefu, Samuel; Gruev, Viktor

    2015-01-01

    Near infrared (NIR) fluorescence imaging has shown great potential for various clinical procedures, including intraoperative image guidance. However, existing NIR fluorescence imaging systems either have a large footprint or are handheld, which limits their usage in intraoperative applications. We present a compact NIR fluorescence imaging system (NFIS) with an image overlay solution based on threshold detection, which can be easily integrated with a goggle display system for intraoperative guidance. The proposed NFIS achieves compactness, light weight, hands-free operation, high-precision superimposition, and a real-time frame rate. In addition, the miniature and ultra-lightweight light-emitting diode tracking pod is easy to incorporate with NIR fluorescence imaging. Based on experimental evaluation, the proposed NFIS solution has a lower detection limit of 25 nM of indocyanine green at 27 fps and realizes a highly precise image overlay of NIR and visible images of mice in vivo. The overlay error is limited within a 2-mm scale at a 65-cm working distance, which is highly reliable for clinical study and surgical use.

  17. Fluorescence detection of glutathione and oxidized glutathione in blood with a NIR-excitable cyanine probe.

    Science.gov (United States)

    Liu, Chang-Hui; Qi, Feng-Pei; Wen, Fu-Bin; Long, Li-Ping; Liu, Ai-Juan; Yang, Rong-Hua

    2018-01-19

    Cyanine has been widely utilized as a near infrared (NIR) fluorophore for detection of glutathione (GSH). However, the excitation of most of the reported cyanine-based probes was less than 800 nm, which inevitably induce biological background absorption and lower the sensitivity, limiting their use for detection of GSH in blood samples. To address this issue, here, a heptamethine cyanine probe (DNIR), with a NIR excitation wavelength at 804 nm and a NIR emission wavelength at 832 nm, is employed for the detection of GSH and its oxidized form (GSSG) in blood. The probe displays excellent selectivity for GSH over GSSG and other amino acids, and rapid response to GSH, in particular a good property for indirect detection of GSSG in the presence of enzyme glutathione reductase and the reducing agent nicotinamideadenine dinucleotide phosphate, without further separation prior to fluorescent measurement. To the best of our knowledge, this is the first attempt to explore NIR fluorescent approach for the simultaneous assay of GSH and GSSG in blood. As such, we expect that our fluorescence sensors with both NIR excitation and NIR emission make this strategy suitable for the application in complex physiological systems.

  18. Fluorescence detection of glutathione and oxidized glutathione in blood with a NIR-excitable cyanine probe

    Science.gov (United States)

    Liu, Chang-hui; Qi, Feng-pei; Wen, Fu-bin; Long, Li-ping; Liu, Ai-juan; Yang, Rong-hua

    2018-04-01

    Cyanine has been widely utilized as a near infrared (NIR) fluorophore for detection of glutathione (GSH). However, the excitation of most of the reported cyanine-based probes was less than 800 nm, which inevitably induce biological background absorption and lower the sensitivity, limiting their use for detection of GSH in blood samples. To address this issue, here, a heptamethine cyanine probe (DNIR), with a NIR excitation wavelength at 804 nm and a NIR emission wavelength at 832 nm, is employed for the detection of GSH and its oxidized form (GSSG) in blood. The probe displays excellent selectivity for GSH over GSSG and other amino acids, and rapid response to GSH, in particular a good property for indirect detection of GSSG in the presence of enzyme glutathione reductase and the reducing agent nicotinamideadenine dinucleotide phosphate, without further separation prior to fluorescent measurement. To the best of our knowledge, this is the first attempt to explore NIR fluorescent approach for the simultaneous assay of GSH and GSSG in blood. As such, we expect that our fluorescence sensors with both NIR excitation and NIR emission make this strategy suitable for the application in complex physiological systems.

  19. Detection of shrimp-derived components in food by real-time fluorescent PCR.

    Science.gov (United States)

    Cao, Jijuan; Yu, Bing; Ma, Lidan; Zheng, Qiuyue; Zhao, Xin; Xu, Junyi

    2011-10-01

    Crustaceans such as shrimp and crabs and their products are important allergens in food, and allergic reactions due to the consumption of shrimp and crabs are frequently reported. However, the chemical properties of shrimp-derived allergens, except for Pen a I, are still unclear. Therefore, it is important to establish a more sensitive and specific method for detecting the composition of foods containing shrimp. In the present study, we developed a real-time fluorescent PCR to identify the specific shrimp-derived components in food. The primers and TaqMan probes for real-time fluorescent PCR were designed based on 16S rRNA genes through comparing a large number of nucleic acid sequences from different species of shrimp that have been published by the National Center for Biotechnology Information. In total, 56 kinds of samples, including different kinds of shrimp, crab, fish, shellfish, and octopus, were subjected to detection by real-time PCR. The results indicated that real-time fluorescent PCR could successfully identify the shrimp-derived components. In order to explore the effect of food processing on detection sensitivity, fish powder containing shrimp powder was treated by heating at 133°C for 30 min. The limit of detection of shrimp-derived components in fish powder was 0.05% (wt/wt).

  20. Improvement of LOD in Fluorescence Detection with Spectrally Nonuniform Background by Optimization of Emission Filtering.

    Science.gov (United States)

    Galievsky, Victor A; Stasheuski, Alexander S; Krylov, Sergey N

    2017-10-17

    The limit-of-detection (LOD) in analytical instruments with fluorescence detection can be improved by reducing noise of optical background. Efficiently reducing optical background noise in systems with spectrally nonuniform background requires complex optimization of an emission filter-the main element of spectral filtration. Here, we introduce a filter-optimization method, which utilizes an expression for the signal-to-noise ratio (SNR) as a function of (i) all noise components (dark, shot, and flicker), (ii) emission spectrum of the analyte, (iii) emission spectrum of the optical background, and (iv) transmittance spectrum of the emission filter. In essence, the noise components and the emission spectra are determined experimentally and substituted into the expression. This leaves a single variable-the transmittance spectrum of the filter-which is optimized numerically by maximizing SNR. Maximizing SNR provides an accurate way of filter optimization, while a previously used approach based on maximizing a signal-to-background ratio (SBR) is the approximation that can lead to much poorer LOD specifically in detection of fluorescently labeled biomolecules. The proposed filter-optimization method will be an indispensable tool for developing new and improving existing fluorescence-detection systems aiming at ultimately low LOD.

  1. Improved sensing using simultaneous deep-UV Raman and fluorescence detection-II

    Science.gov (United States)

    Hug, W. F.; Bhartia, R.; Sijapati, K.; Beegle, L. W.; Reid, R. D.

    2014-05-01

    Photon Systems in collaboration with JPL is continuing development of a new technology robot-mounted or hand-held sensor for reagentless, short-range, standoff detection and identification of trace levels chemical, biological, and explosive (CBE) materials on surfaces. This deep ultraviolet CBE sensor is the result of Army STTR and DTRA programs. The evolving 10 to 15 lb, 20 W, sensor can discriminate CBE from background clutter materials using a fusion of deep UV excited resonance Raman (RR) and laser induced native fluorescence (LINF) emissions collected is less than 1 ms. RR is a method that provides information about molecular bonds, while LINF spectroscopy is a much more sensitive method that provides information regarding the electronic configuration of target molecules. Standoff excitation of suspicious packages, vehicles, persons, and other objects that may contain hazardous materials is accomplished using excitation in the deep UV where there are four main advantages compared to near-UV, visible or near-IR counterparts. 1) Excited between 220 and 250 nm, Raman emission occur within a fluorescence-free region of the spectrum, eliminating obscuration of weak Raman signals by fluorescence from target or surrounding materials. 2) Because Raman and fluorescence occupy separate spectral regions, detection can be done simultaneously, providing an orthogonal set of information to improve both sensitivity and lower false alarm rates. 3) Rayleigh law and resonance effects increase Raman signal strength and sensitivity of detection. 4) Penetration depth into target in the deep UV is short, providing spatial/spectral separation of a target material from its background or substrate. 5) Detection in the deep UV eliminates ambient light background and enable daylight detection.

  2. Two-color fluorescent in situ hybridization in the embryonic zebrafish brain using differential detection systems

    Directory of Open Access Journals (Sweden)

    Hauptmann Giselbert

    2011-07-01

    Full Text Available Abstract Background Whole-mount in situ hybridization (WISH is extensively used to characterize gene expression patterns in developing and adult brain and other tissues. To obtain an idea whether a novel gene might be involved in specification of a distinct brain subdivision, nucleus or neuronal lineage, it is often useful to correlate its expression with that of a known regional or neuronal marker gene. Two-color fluorescent in situ hybridization (FISH can be used to compare different transcript distributions at cellular resolution. Conventional two-color FISH protocols require two separate rounds of horseradish peroxidase (POD-based transcript detection, which involves tyramide signal amplification (TSA and inactivation of the first applied antibody-enzyme conjugate before the second detection round. Results We show here that the alkaline phosphatase (AP substrates Fast Red and Fast Blue can be used for chromogenic as well as fluorescent visualization of transcripts. To achieve high signal intensities we optimized embryo permeabilization properties by hydrogen peroxide treatment and hybridization conditions by application of the viscosity-increasing polymer dextran sulfate. The obtained signal enhancement allowed us to develop a sensitive two-color FISH protocol by combining AP and POD reporter systems. We show that the combination of AP-Fast Blue and POD-TSA-carboxyfluorescein (FAM detection provides a powerful tool for simultaneous fluorescent visualization of two different transcripts in the zebrafish brain. The application of different detection systems allowed for a one-step antibody detection procedure for visualization of transcripts, which significantly reduced working steps and hands-on time shortening the protocol by one day. Inactivation of the first applied reporter enzyme became unnecessary, so that false-positive detection of co-localization by insufficient inactivation, a problem of conventional two-color FISH, could be

  3. Rapid determination of ampicillin in bovine milk by liquid chromatography with fluorescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Ang, C.Y.W.; Luo, Wenhong [National Center for Toxicological Research, Jefferson, AR (United States)

    1997-01-01

    A rapid and sensitive liquid chromatographic (LC) method was developed for the determination of ampicillin residues in raw bovine milk, processed skim milk, and pasteurized, homogenized whole milk with vitamin D. Milk samples were deproteinized with trichloroacetic acid (TCA) and acetonictrile. After centrifugation, the clear supernatant was reacted with formaldehyde and TCA under heat. The major fluorescent derivative of ampicillin was then determined by reversed-phase LC with fluorescence detection. Average recoveries of ampicillin fortified at 5, 10, and 20 ppb (ng/mL) were all >85% with coefficients of variation <10%. Limits of detection ranged from 0.31 to 0.51 ppb and limits of quantitation, from 0.66 to 1.2 ppb. After appropriate validation, this method should be suitable for rapid analysis of milk for ampicillin residues at the tolerance level of 10 ppb. 16 refs., 4 figs., 3 tabs.

  4. Green synthesis of fluorescent carbon dots for sensitive detection of Fe2+ and hydrogen peroxide

    Science.gov (United States)

    Shi, Jing; Ni, Gang; Tu, Jinchun; Jin, Xiaoyong; Peng, Juan

    2017-06-01

    In this paper, the green synthesis of fluorescent carbon dots (CDs) via one-step hydrothermal treatment of cornstalk was investigated. This approach is facile, economical, and effective. The obtained CDs with an average diameter of 5.2 nm possess many excellent properties such as emitting blue fluorescence under UV light (365 nm), high monodispersity, good stability, excellent water dispersibility, and absolute quantum yield of 7.6%. Then, these CDs were used as sensing probes for the detection of Fe2+ and H2O2 with detection limits as low as 0.18 and 0.21 μM, respectively. This sensing platform shows advantages such as high selectivity, good precision, rapid operation, and avoiding the precipitation of iron oxyhydroxides.

  5. Phosphorus doped graphitic carbon nitride nanosheets as fluorescence probe for the detection of baicalein.

    Science.gov (United States)

    Wang, Xuan; Li, Xuebing; Chen, Wenfang; Wang, Rulin; Bian, Wei; Choi, Martin M F

    2018-02-24

    Phosphorus doped graphitic carbon nitride (P-g-C 3 N 4 ) nanosheets were synthesized by calcination. P-g-C 3 N 4 nanosheets were characterized by XRD, XPS, TEM, fluorescence, ultraviolet-visible absorption and Fourier transform infrared spectroscopy. The fluorescence of the P-g-C 3 N 4 nanosheets was gradually quenched with the increase in the concentration of baicalein at room temperature. The proposed probe was used for the determination of baicalein in the concentration 2.0-30μM with a detection limit of 53nM. The quenching mechanism was discussed. The P-g-C 3 N 4 nanosheets have been successfully applied for effective and selective detection of baicalein in human urine samples and blood samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Experimental Detection of Branching at a Conical Intersection in a Highly Fluorescent Molecule.

    Science.gov (United States)

    Brazard, Johanna; Bizimana, Laurie A; Gellen, Tobias; Carbery, William P; Turner, Daniel B

    2016-01-07

    Conical intersections are molecular configurations at which adiabatic potential-energy surfaces touch. They are predicted to be ubiquitous, yet condensed-phase experiments have focused on the few systems with clear spectroscopic signatures of negligible fluorescence, high photoactivity, or femtosecond electronic kinetics. Although rare, these signatures have become diagnostic for conical intersections. Here we detect a coherent surface-crossing event nearly two picoseconds after optical excitation in a highly fluorescent molecule that has no photoactivity and nanosecond electronic kinetics. Time-frequency analysis of high-sensitivity measurements acquired using sub-8 fs pulses reveals phase shifts of the signal due to branching of the wavepacket through a conical intersection. The time-frequency analysis methodology demonstrated here on a model compound will enable studies of conical intersections in molecules that do not exhibit their diagnostic signatures. Improving the ability to detect conical intersections will enrich the understanding of their mechanistic role in molecular photochemistry.

  7. Liquid nitrogen-assisted synthesis of fluorescent carbon dots from Blueberry and their performance in Fe3+ detection

    Science.gov (United States)

    Aslandaş, Ayşe Merve; Balcı, Neslihan; Arık, Mustafa; Şakiroğlu, Halis; Onganer, Yavuz; Meral, Kadem

    2015-11-01

    Fluorescent carbon dots (C-dots) were synthesized by a facile method containing liquid N2 treatment and centrifuge processes. The photophysical properties of the C-dots in an aqueous solution were examined at various conditions such as concentration, temperature, pH and excitation wavelength by using UV-vis absorption, fluorescence and time-resolved fluorescence spectroscopies. The C-dots emitted a broad fluorescence between approximately 350-550 nm and their fluorescence was tuned by changing excitation wavelength. The as-prepared C-dots were applied to Fe3+ detection from aqueous solution. Spectroscopic data revealed that the as-prepared C-dots were used to detect Fe3+ in the range of 12.5 μM to 100 μM as a fluorescence sensor.

  8. Optimization of Synthesis and Modification of ZnSe/ZnS Quantum Dots for Fluorescence Detection ofEscherichia coil.

    Science.gov (United States)

    Wu, Pian; Huang, Ruixue; Li, Guiyin; He, Yayuan; Chen, Cuimei; Xiao, Wen; Ding, Ping

    2018-05-01

    This study prepared an innovative 3-mercaptopropionic acid modified ZnSe/ZnS core/shell quantum dots (MPA-ZnSe/ZnS QDs), and established a rapid fluorescence method to detect the E. coli cells count by using MPA-ZnSe/ZnS QDs as fluorescence probe. The formulation variables and process were optimized using the response surface methodology (RSM). Fluorescence microscopy was used to obtain fluorescence microscope images of MPA-ZnSe/ZnS QDs that bind to bacteria. The fluorescence peak intensity increases with increasing cells count in the range of 101-108 CFU/mL. Compared with the traditional based on fluorescent detection methods, this method is more convenient and useful in the bacterial count determination.

  9. The X-ray-fluorescence facility at ANKA, Karlsruhe: Minimum detection limits and micro probe capabilities

    CERN Document Server

    Simon, R; Hagelstein, M

    2003-01-01

    At the recently constructed synchrotron radiation facility ANKA at Karlsruhe, Germany, a beamline partially dedicated to X-ray fluorescence has been constructed where TXRF and micro probe SRXRF experiments can be performed. The beam line with its retractable double multilayer monochromator is described. First measurements on reference samples allow a preliminary characterization of beam line parameters like exploitable energy range and the energy resolution as well as the sensitivity of the set-up in means of minimum detection limits.

  10. Detection of carcinoembryonic antigen using functional magnetic and fluorescent nanoparticles in magnetic separators

    Science.gov (United States)

    Tsai, H. Y.; Chang, C. Y.; Li, Y. C.; Chu, W. C.; Viswanathan, K.; Bor Fuh, C.

    2011-06-01

    We combined a sandwich immunoassay, anti-CEA/CEA/anti-CEA, with functional magnetic ( 80 nm) and fluorescent ( 180 nm) nanoparticles in magnetic separators to demonstrate a detection method for carcinoembryonic antigen (CEA). Determination of CEA in serum can be used in clinical diagnosis and monitoring of tumor-related diseases. The CEA concentrations in samples were deduced and determined based on the reference plot using the measured fluorescent intensity of sandwich nanoparticles from the sample. The linear range of CEA detection was from 18 ng/mL to 1.8 pg/mL. The detection limit of CEA was 1.8 pg/mL. In comparison with most other detection methods, this method had advantages of lower detection limit and wider linear range. The recovery was higher than 94%. The CEA concentrations of two serum samples were determined to be 9.0 and 55 ng/mL, which differed by 6.7% (9.6 ng/mL) and 9.1% (50 ng/mL) from the measurements of enzyme-linked immunosorbent assay (ELISA), respectively. The analysis time can be reduced to one third of ELISA. This method has good potential for other biomarker detections and biochemical applications.

  11. Detection of carcinoembryonic antigen using functional magnetic and fluorescent nanoparticles in magnetic separators

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, H. Y., E-mail: annetsai@csmu.edu.tw [Chung Shan Medical University, Department of Applied Chemistry (China); Chang, C. Y.; Li, Y. C.; Chu, W. C.; Viswanathan, K.; Bor Fuh, C., E-mail: cbfuh@ncnu.edu.tw [National Chi Nan University, Department of Applied Chemistry (China)

    2011-06-15

    We combined a sandwich immunoassay, anti-CEA/CEA/anti-CEA, with functional magnetic ({approx}80 nm) and fluorescent ({approx}180 nm) nanoparticles in magnetic separators to demonstrate a detection method for carcinoembryonic antigen (CEA). Determination of CEA in serum can be used in clinical diagnosis and monitoring of tumor-related diseases. The CEA concentrations in samples were deduced and determined based on the reference plot using the measured fluorescent intensity of sandwich nanoparticles from the sample. The linear range of CEA detection was from 18 ng/mL to 1.8 pg/mL. The detection limit of CEA was 1.8 pg/mL. In comparison with most other detection methods, this method had advantages of lower detection limit and wider linear range. The recovery was higher than 94%. The CEA concentrations of two serum samples were determined to be 9.0 and 55 ng/mL, which differed by 6.7% (9.6 ng/mL) and 9.1% (50 ng/mL) from the measurements of enzyme-linked immunosorbent assay (ELISA), respectively. The analysis time can be reduced to one third of ELISA. This method has good potential for other biomarker detections and biochemical applications.

  12. Highly selective and sensitive fluorescent chemosensor for femtomolar detection of silver ion in aqueous medium

    Directory of Open Access Journals (Sweden)

    Abraham Daniel Arulraj

    2015-12-01

    Full Text Available The chemical sensing for the trace level detection of silver ion in aqueous solution still remains a challenge using simple, rapid, and inexpensive method. We report that thionine can be used as a fluorescent probe for the detection of Ag+ ion. The successive addition of Ag+ ion to the solution containing thionine quenches (turns-off the fluorescence intensity of thionine. Association and quenching constants have been estimated by the Benesi–Hildebrand method and Stern–Volmer plot, respectively. From the plot, the nature of the fluorescence quenching was confirmed as static quenching. An important feature of our chemosensor is high selectivity towards the determination of silver ion in aqueous solution over the other competitive metal ions. The detection limit of the sensor achieved 5 fM for Ag+ ion, which is superior to all previously reported chemosensors. The NMR and FT-IR studies were also carried out to support the complex formation between thionine and Ag+ ion. The practicality of the proposed chemosensor for determination of Ag+ ion was carried in untreated water samples.

  13. A small azide-modified thiazole-based reporter molecule for fluorescence and mass spectrometric detection

    Directory of Open Access Journals (Sweden)

    Stefanie Wolfram

    2014-10-01

    Full Text Available Molecular probes are widely used tools in chemical biology that allow tracing of bioactive metabolites and selective labeling of proteins and other biomacromolecules. A common structural motif for such probes consists of a reporter that can be attached by copper(I-catalyzed 1,2,3-triazole formation between terminal alkynes and azides to a reactive headgroup. Here we introduce the synthesis and application of the new thiazole-based, azide-tagged reporter 4-(3-azidopropoxy-5-(4-bromophenyl-2-(pyridin-2-ylthiazole for fluorescence, UV and mass spectrometry (MS detection. This small fluorescent reporter bears a bromine functionalization facilitating the automated data mining of electrospray ionization MS runs by monitoring for its characteristic isotope signature. We demonstrate the universal utility of the reporter for the detection of an alkyne-modified small molecule by LC–MS and for the visualization of a model protein by in-gel fluorescence. The novel probe advantageously compares with commercially available azide-modified fluorophores and a brominated one. The ease of synthesis, small size, stability, and the universal detection possibilities make it an ideal reporter for activity-based protein profiling and functional metabolic profiling.

  14. Detection of 13,19-didesmethyl C spirolide by fluorescence polarization using Torpedo electrocyte membranes.

    Science.gov (United States)

    Fonfría, Eva S; Vilariño, Natalia; Molgó, Jordi; Aráoz, Rómulo; Otero, Paz; Espiña, Begoña; Louzao, M Carmen; Alvarez, Mercedes; Botana, Luis M

    2010-08-01

    Fluorescence polarization (FP) is a powerful tool for studying molecular interactions by monitoring changes in the apparent size of fluorescent molecules. In this paper, a previously described fluorescence polarization assay was used to detect 13,19-didesmethyl C spirolide. The assay is based on the competition of cyclic imine marine biotoxins with alpha-bungarotoxin for binding to nicotinic acetylcholine receptor-enriched membranes of Torpedo marmorata. The 13,19-didesmethyl C spirolide was detected in buffer and mussel matrix. The sensitivity of the assay for the 13,19-didesmethyl C spirolide and the 13-desmethyl C spirolide was similar. After an acetone/chloroform extraction of spiked mussel meat, the average recovery rate of 13,19-didesmethyl C spirolide was 77.7 +/- 1.9%. The quantification range for this toxin in mussel was 40-200 microg/kg of shellfish meat. This assay can be used to detect the spirolides 13,19-didesmethyl C spirolide and 13-desmethyl C spirolide, in shellfish as a screening assay. Copyright 2010 Elsevier Inc. All rights reserved.

  15. Toxorhynchites-fluorescent antibody system for the detection of bluetongue virus from Culicoides midges (Diptera: Ceratopogonidae).

    Science.gov (United States)

    Habibur Rahman, A; Manickam, R

    1997-12-01

    A new system, the Toxorhynchites-fluorescent antibody (TFA) test in which the larvae of Toxorhynchites splendens mosquitoes were used for the detection of bluetongue virus (BTV) from Culicoides midges, was developed. Twenty-seven pools of Culicoides midges were collected from bluetongue-prone areas of Tamil Nadu by use of the light-trap and suction-trap methods. A suspension of each pool was injected intrathoracically into T. splendens IV instar larvae and inoculated onto Vero cell monolayers. An indirect fluorescent antibody technique and an immunoperoxidase test were used to detect BTV antigen in smears of crushed midges, crushed larval head smears after incubation for 7 d at 28 degrees and cell monolayers showing cytopathic effects 48 h post inoculation. The suspensions were also injected intravenously into embryonated chicken eggs, and the characteristic BTV-induced lesion(s), viz. cherry-red appearance of embryos, were observed after 48 h. Virus was confirmed by a qualitative neutralization test conducted simultaneously in embryonated chicken eggs. A total of seven out of 27 samples (26%) were positive for the presence of BTV antigen in all the diagnostic systems used. Since BTV propagates readily in experimentally infected T. splendens larvae and the BTV antigen can be detected by the fluorescent antibody technique with a sensitivity comparable to that for virus propagated in tissue culture and embryonated eggs, the TFA system can be adopted as a new method for the isolation of BTV from vectors. The advantages of the TFA system are discussed.

  16. Secondary caries detection with a novel fluorescence-based camera system in vitro

    Science.gov (United States)

    Brede, Olivier; Wilde, Claudia; Krause, Felix; Frentzen, Matthias; Braun, Andreas

    2010-02-01

    The aim of the study was to assess the ability of a fluorescence based optical system to detect secondary caries. The optical detecting system (VistaProof) illuminates the tooth surfaces with blue light emitted by high power GaN-LEDs at 405 nm. Employing this almost monochromatic excitation, fluorescence is analyzed using a RGB camera chip and encoded in color graduations (blue - red - orange - yellow) by a software (DBSWIN), indicating the degree of caries destruction. 31 freshly extracted teeth with existing fillings and secondary caries were cleaned, excavated and refilled with the same kind of restorative material. 19 of them were refilled with amalgam, 12 were refilled with a composite resin. Each step was analyzed with the respective software and analyzed statistically. Differences were considered as statistically significant at p0.05). There was a significant difference between baseline measurements of the teeth primarily filled with composite resins and the refilled situation (p=0.014). There was also a significant difference between the non-excavated and the excavated group (Composite p=0.006, Amalgam p=0.018). The in vitro study showed, that the fluorescence based system allows detecting secondary caries next to composite resin fillings but not next to amalgam restorations. Cleaning of the teeth is not necessary, if there is no visible plaque. Further studies have to show, whether the system shows the same promising results in vivo.

  17. Light emitting diode, photodiode-based fluorescence detection system for DNA analysis with microchip electrophoresis.

    Science.gov (United States)

    Hall, Gordon H; Glerum, D Moira; Backhouse, Christopher J

    2016-02-01

    Electrophoretic separation of fluorescently end-labeled DNA after a PCR serves as a gold standard in genetic diagnostics. Because of their size and cost, instruments for this type of analysis have had limited market uptake, particularly for point-of-care applications. This might be changed through a higher level of system integration and lower instrument costs that can be realized through the use of LEDs for excitation and photodiodes for detection--if they provide sufficient sensitivity. Here, we demonstrate an optimized microchip electrophoresis instrument using polymeric fluidic chips with fluorescence detection of end-labeled DNA with a LOD of 0.15 nM of Alexa Fluor 532. This represents orders of magnitude improvement over previously reported instruments of this type. We demonstrate the system with an electrophoretic separation of two PCR products and their respective primers. We believe that this is the first LED-induced fluorescence microchip electrophoresis system with photodiode-based detection that could be used for standard applications of PCR and electrophoresis. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Versatile single-molecule multi-color excitation and detection fluorescence setup for studying biomolecular dynamics

    KAUST Repository

    Sobhy, M. A.

    2011-11-07

    Single-molecule fluorescence imaging is at the forefront of tools applied to study biomolecular dynamics both in vitro and in vivo. The ability of the single-molecule fluorescence microscope to conduct simultaneous multi-color excitation and detection is a key experimental feature that is under continuous development. In this paper, we describe in detail the design and the construction of a sophisticated and versatile multi-color excitation and emission fluorescence instrument for studying biomolecular dynamics at the single-molecule level. The setup is novel, economical and compact, where two inverted microscopes share a laser combiner module with six individual laser sources that extend from 400 to 640 nm. Nonetheless, each microscope can independently and in a flexible manner select the combinations, sequences, and intensities of the excitation wavelengths. This high flexibility is achieved by the replacement of conventional mechanical shutters with acousto-optic tunable filter (AOTF). The use of AOTF provides major advancement by controlling the intensities, duration, and selection of up to eight different wavelengths with microsecond alternation time in a transparent and easy manner for the end user. To our knowledge this is the first time AOTF is applied to wide-field total internal reflection fluorescence (TIRF) microscopy even though it has been commonly used in multi-wavelength confocal microscopy. The laser outputs from the combiner module are coupled to the microscopes by two sets of four single-mode optic fibers in order to allow for the optimization of the TIRF angle for each wavelength independently. The emission is split into two or four spectral channels to allow for the simultaneous detection of up to four different fluorophores of wide selection and using many possible excitation and photoactivation schemes. We demonstrate the performance of this new setup by conducting two-color alternating excitation single-molecule fluorescence resonance energy

  19. Detection of protease activity by fluorescent protein FRET sensors: from computer simulation to live cells

    Science.gov (United States)

    Goryashchenko, Alexander S.; Khrenova, Maria G.; Savitsky, Alexander P.

    2018-04-01

    Förster resonance energy transfer (FRET) sensors are widely used for the detection of protease activity in vitro and in vivo. Usually they consist of a FRET pair connected with a polypeptide linker containing a specific cleavage site for the relevant protease. Use of the fluorescent proteins as components of the FRET pair allows genetic encoding of such sensors and solves the problem of their delivery into live cells and animals. There are several ways to improve the properties of such sensors, mainly to increase FRET efficiency and therefore the dynamic range. One of the ways to achieve this is to use a non-fluorescent chromoprotein as an acceptor. Molecular dynamic simulations may assist in the construction of linker structures connecting donor and acceptor molecules. Estimation of the orientation factor κ 2 can be obtained by methods based on quantum theory and combined quantum mechanics/molecular mechanics approaches. The linker can be structured by hydrophobic interactions, bringing it into a closed conformation that shortens the distance between donor and acceptor and, consequently, increases FRET efficiency. We analyzed the effects of different linker structures on the detection of caspase-3 activity using a non-fluorescent acceptor. Also we have constructed the Tb3+- TagRFP sensor in which a complex of the terbium ion and terbium-binding peptide is used as a donor. This allowed us to use the unique property of lanthanide ions—fluorescence lifetime up to milliseconds—to perform measurements with time delay and exclude the nanosecond-order fluorescence. Using our systems as a starting point, by changing the recognition site in the linker it is possible to perform imaging of different protease activity in vitro or in vivo.

  20. Fluorescence/depolarization lidar for mid-range stand-off detection of biological agents

    Science.gov (United States)

    Mierczyk, Z.; Kopczyński, K.; Zygmunt, M.; Wojtanowski, J.; Młynczak, J.; Gawlikowski, A.; Młodzianko, A.; Piotrowski, W.; Gietka, A.; Knysak, P.; Drozd, T.; Muzal, M.; Kaszczuk, M.; Ostrowski, R.; Jakubaszek, M.

    2011-06-01

    LIDAR system for real-time standoff detection of bio-agents is presented and preliminary experimental results are discussed. The detection approach is based on two independent physical phenomena: (1) laser induced fluorescence (LIF), (2) depolarization resulting from elastic scattering on non-spherical particles. The device includes three laser sources, two receiving telescopes, depolarization component and spectral signature analyzing spectrograph. It was designed to provide the stand-off detection capability at ranges from 200 m up to several kilometers. The system as a whole forms a mobile platform for vehicle or building installation. Additionally, it's combined with a scanning mechanics and advanced software, which enable to conduct the semi-automatic monitoring of a specified space sector. For fluorescence excitation, 3-rd (355 nm) and 4-th (266 nm) harmonics of Nd:YAG pulsed lasers are used. They emit short (~6 ns) pulses with the repetition rate of 20 Hz. Collecting optics for fluorescence echo detection and spectral content analysis includes 25 mm diameter f/4 Newton telescope, Czerny Turner spectrograph and 32-channel PMT. Depending on the grating applied, the spectral resolution from 20 nm up to 3 nm per channel can be achieved. The system is also equipped with an eye-safe (1.5 μm) Nd:YAG OPO laser for elastic backscattering/depolarization detection. The optical echo signal is collected by Cassegrain telescope with aperture diameter of 12.5 mm. Depolarization detection component based on polarizing beam-splitter serves as the stand-off particle-shape analyzer, which is very valuable in case of non-spherical bio-aerosols sensing.

  1. A rapid-screening approach to detect and quantify microplastics based on fluorescent tagging with Nile Red

    Science.gov (United States)

    Maes, Thomas; Jessop, Rebecca; Wellner, Nikolaus; Haupt, Karsten; Mayes, Andrew G.

    2017-03-01

    A new approach is presented for analysis of microplastics in environmental samples, based on selective fluorescent staining using Nile Red (NR), followed by density-based extraction and filtration. The dye adsorbs onto plastic surfaces and renders them fluorescent when irradiated with blue light. Fluorescence emission is detected using simple photography through an orange filter. Image-analysis allows fluorescent particles to be identified and counted. Magnified images can be recorded and tiled to cover the whole filter area, allowing particles down to a few micrometres to be detected. The solvatochromic nature of Nile Red also offers the possibility of plastic categorisation based on surface polarity characteristics of identified particles. This article details the development of this staining method and its initial cross-validation by comparison with infrared (IR) microscopy. Microplastics of different sizes could be detected and counted in marine sediment samples. The fluorescence staining identified the same particles as those found by scanning a filter area with IR-microscopy.

  2. Highly sensitive fluorescence resonance energy transfer (FRET)-based nanosensor for rapid detection of clenbuterol

    Science.gov (United States)

    Nghia Nguyen, Duc; Ngo, Trinh Tung; Liem Nguyen, Quang

    2012-09-01

    In this study we investigate the fabrication of a fluorescence resonance energy transfer (FRET)-based nanosensor for the detection of clenbuterol. The nanosensor consists of CdTe quantum dots coated by clenbuterol recognizable agent naphthol and diazotized clenbuterol. Changes in maximal photoluminescent intensities of the nanosensor were utilized to measure clenbuterol concentrations. The maximal photoluminescent intensities of the nanosensor were found to decrease with increasing clenbuterol concentrations, following a linear correlation. We have successfully fabricated a nanosensor for detection of clenbuterol with sensitivity up to 10 pg ml-1.

  3. The Fluorescence Enhancement of Mercury Detected in Food Based on Rhodamine Derivatives.

    Science.gov (United States)

    Fan, Cai-ling; Xie, Pu-hui; Cui, Shu-min; Yang, Li-na; Sun, Qing; Ai, Zhi-lu

    2015-05-01

    Recently, the problem of food security is more and more serious, and people pay attention to mercury because of the toxic of it. A new approach for the determination of mercury content in foodstuff is devised. In this paper, first, we design and synthesis a new kind of fluorescent probe whose matrix based on rhodamine B, hydrazine hydrate and hydroxy benzaldehyde. Through the analysis of H-NMR spectra of the synthesized product L1, we confirm that the synthetic substance is the adjacent carboxyl benzaldehyde hydrazone structure generation of rhodamine B. Then, we measure the fluorescence signal intensity of the probe with different concentrations of mercury ions fully upon complexation by fluorescence spectrometer and we can study the relationship between the mercury ion concentration and the fluorescence intensity and draw the standard working curve. Following, It's time to discuss the microwave digestion processing of tea, after digestion we use the synthetic probe Li for determination of mercury content in tea. The experimental results show that the maximum excitation wavelength of the probe and coordination compound are 568. 05 and 560. 00 nm, the maximum emission wavelength are 587. 94 and 580. 00 nm. Then we can find the best testing conditions to improve the degree of accuracy, that is: room temperature, 50% the methanol solution, 3. 0 mL pH 4. 0 buffer solution, in the extent of 30 min. The experimental results show that Na+, K+, Ca2+, Cu2+, Zn2+, Al3+ have little impact on the fluorescence intensity of the:probe. Fe3+, Mg2+, Ba2+ has a weak enhancement to the fluorescence intensity of the probe. While a low concentrations of Hg2+ have an obviously enhanced effect on the fluorescence intensity of the probe. In contrast to other metal ions, the probe for Hg2+ has a good selectivity. Linear relationship between the magnitude of increase in fluorescence intensity and concentration of mercury ion was in the range of 5~20 ng . L-1 with detection limit (3S/N) of

  4. Non-invasive detection of aflatoxin-contaminated figs using fluorescence and multispectral imaging.

    Science.gov (United States)

    Kalkan, Habil; Güneş, Ali; Durmuş, Efkan; Kuşçu, Alper

    2014-01-01

    Agricultural products are prone to aflatoxin (AF)-producing moulds (Aspergillus flavus, A. parasiticus) during harvesting, drying, processing and also storage. AF is a mycotoxin that may cause liver cancer when consumed in amounts higher than allowed limits. Figs, like other agricultural products, are mostly affected by AF-producing moulds and these moulds usually produce kojic acid together with AF. Kojic acid is a fluorescent compound and exhibiting bright greenish yellow fluorescence (BGYF) under ultraviolet (UV) light. Using this fluorescence property, fig-processing plants manually select and remove the BGYF+ figs to reduce the AF level of the processed figs. Although manual selection is based on subjective criteria and strongly depends on the expertise level of the workers, it is known as the most effective way of removing AF-contaminated samples. However, during manual selection, workers are exposed to UV radiation and this brings skin health problems. In this study, we individually investigated the figs to measure their fluorescence level, surface mould concentration and AF levels and noted a strong correlation between mould concentration and BGYF and AF, and BGYF and surface. In addition to a pairwise correlation, we proposed a machine-vision and machine-learning approach to detect the AF-contaminated figs using their multispectral images under UV light. The figs were classified in two different approaches considering their surface mould and AF level with error rates of 9.38% and 11.98%, respectively.

  5. Detection of Colorectal Cancer by a Quantitative Fluorescence Determination of DNA Amplification in Stool

    Directory of Open Access Journals (Sweden)

    Daniele Calistri

    2004-09-01

    Full Text Available DNA amplification of exfoliated cells in stool repre sents an inexpensive and rapid test, but has only 50% to 60% sensitivity. A new quantitative method, calle( fluorescence long DNA, was developed and validate( in our laboratory on stool obtained from 86 patient., with primary colorectal cancer and from 62 health individuals. It consists of the amplification of stoo DNA with fluorescence primers and the quantification of the amplification using a standard curve. Results are arbitrarily expressed in nanograms. The potential of thi new method compared to the conventional approact was analyzed in a subgroup of 94 individuals (51 patients and 38 healthy volunteers. In the presen series, DNA amplification analysis showed a specific ity of 97% and a sensitivity of only 50%. Conversely fluorescence DNA evaluation, using the best cutoff o 25 ng, showed a sensitivity of about 76% and a spec ificity of 93%. Similar sensitivity was observed regard less of Dukes stage, tumor location, and size, thu., also permitting the detection of early-stage tumors The present study seems to indicate that quantitative fluorescence DNA determination in stool successfully identifies colorectal cancer patients with a sensitivity comparable, if not superior, to that of multiple gene analysis but at a lower cost and in a shorter time.

  6. Selective fluorescence detection of Cu{sup 2+} in aqueous solution and living cells

    Energy Technology Data Exchange (ETDEWEB)

    Saleem, Muhammad; Lee, Ki-Hwan, E-mail: khlee@kongju.ac.kr

    2014-01-15

    A rhodamine B semicarbazide 3 was synthesized by the reaction of rhodamine B acid chloride 2 with hydrazine carboxamide hydrochloride under reflux with triethyl amine in acetonitrile. It was used as selective fluorescent and colorimetric sensor for visual detection of Cu{sup 2+} over competitive ions (Fe{sup 3+},Fe{sup 2+}, Cr{sup 3+}, Cd{sup 2+}, Pb{sup 2+}, Zn{sup 2+}, Hg{sup 2+}, Co{sup 2+}, Ni{sup 2+}, Ca{sup 2+}, Mg{sup 2+}, Ag{sup 2+}, Mn{sup 2+}, Sr{sup 2+}, Cs{sup 2+}, Na{sup +}, K{sup +}, Li{sup +}) in aqueous methanol (1:1, v/v), exhibiting a fast response time, less than few second and a detection limit of 1.6×10{sup −7} mol/L at neutral pH. The proposed sensing system can be successfully applicable for determination of Cu{sup 2+} in waste water samples showing turn on fluorescence response and for further monitoring of intracellular Cu{sup 2+} levels in living cells with high sensitivity and selectivity at micro molar level concentrations using confocal fluorescence spectroscopy. The synthesis of probe 3 was confirmed by {sup 1}H NMR, {sup 13}C NMR and mass spectrometric analysis. -- Highlights: • New chemosensor rhodamine B semicarbazide 3 was synthesized. • Addition of Cu{sup +2} ion into aqueous solution of probe 3 gave visual color changes as well as fluorescent off/on observations. • The proposed spirolactam ring opening mechanism of the synthesized probe triggered by copper ion was revealed by using mass spectrum. • High selectivity and sensitivity of probe 3 towards Cu{sup +2} are excellent enough to detect micromolar level of Cu{sup +2} ion even in aqueous media and living cells.

  7. Radiographic and laser fluorescence methods have no benefits for detecting caries in primary teeth.

    Science.gov (United States)

    Mendes, F M; Novaes, T F; Matos, R; Bittar, D G; Piovesan, C; Gimenez, T; Imparato, J C P; Raggio, D P; Braga, M M

    2012-01-01

    Clinical guidelines advise that dentists take radiographs in children to detect caries lesions missed by visual inspection; however, due to the current low caries prevalence in most countries, we hypothesized that the adjunct methods of caries detection would not significantly improve the detection of primary molar lesions in comparison to visual inspection alone. We evaluated the performance of visual inspection, alone or in combination with radiographic and laser fluorescence pen (LFpen) methods, in detecting occlusal and approximal caries lesions in primary molars. Two examiners evaluated children who had sought dental treatment with these diagnostic strategies. The reference standard involved the temporary separation of approximal and operative interventions for occlusal surfaces. The sensitivity, specificity, accuracy and utility of diagnostic strategies were calculated. Simultaneous combined strategies increased sensitivities but decreased specificities. Furthermore, no differences were observed in accuracy and utility, parameters more influenced by caries prevalence. In conclusion, adjunct radiographic and laser fluorescence methods offer no benefits to the detection of caries in primary teeth in comparison to visual inspection alone; hence, present clinical guidelines should be re-evaluated. Copyright © 2012 S. Karger AG, Basel.

  8. Development of narrow-band fluorescence index for the detection of aflatoxin contaminated corn

    Science.gov (United States)

    Yao, Haibo; Hruska, Zuzana; Kincaid, Russell; Ononye, Ambrose; Brown, Robert L.; Bhatnagar, Deepak; Cleveland, Thomas E.

    2011-06-01

    Aflatoxin is produced by the fungus Aspergillus flavus when the fungus invades developing corn kernels. Because of its potent toxicity, the levels of aflatoxin are regulated by the Food and Drug Administration (FDA) in the US, allowing 20 ppb (parts per billion) limits in food, and feed intended for interstate commerce. Currently, aflatoxin detection and quantification methods are based on analytical tests. These tests require the destruction of samples, can be costly and time consuming, and often rely on less than desirable sampling techniques. Thus, the ability to detect aflatoxin in a rapid, non-invasive way is crucial to the corn industry in particular. This paper described how narrow-band fluorescence indices were developed for aflatoxin contamination detection based on single corn kernel samples. The indices were based on two bands extracted from full wavelength fluorescence hyperspectral imagery. The two band results were later applied to two large sample experiments with 25 g and 1 kg of corn per sample. The detection accuracies were 85% and 95% when 100 ppb threshold was used. Since the data acquisition period is significantly lower for several image bands than for full wavelength hyperspectral data, this study would be helpful in the development of real-time detection instrumentation for the corn industry.

  9. Native fluorescence detection of biomolecular and pharmaceutical compounds in capillary electrophoresis: detector designs, performance and applications: A review

    NARCIS (Netherlands)

    de Kort, B.J.; de Jong, G.J.; Somsen, G.W.

    2013-01-01

    This review treats the coupling of capillary electrophoresis (CE) with fluorescence detection (Flu) for the analysis of natively fluorescent biomolecular and pharmaceutical compounds. CE-Flu combines the excellent separation efficiency of CE with the high selectivity and sensitivity of Flu. In

  10. Fluorescence detection of pesticides using quantum dot materials – A review

    Energy Technology Data Exchange (ETDEWEB)

    Nsibande, S.A.; Forbes, P.B.C., E-mail: patricia.forbes@up.ac.za

    2016-11-16

    High pesticide use, especially in agriculture, can lead to environmental pollution and potentially adverse health effects. As result, pesticide residues end up in different media, including water and food products, which may serve as direct routes for human exposure. There is thus a continuous drive to develop analytical methods for screening and quantification of these compounds in the different environmental media in which they may occur. Development of quantum dot (QD) based sensors for monitoring pesticides has gained momentum in recent years. QD materials have excellent and unique optical properties and have high fluorescence quantum yields compared to other fluorophores. They have thus been used in numerous studies for the development of probes for organic pollutants. In this paper we specifically review their application as fluorescence probes for pesticide detection in different media including water and in fruits and vegetables. The low detection limits reported demonstrate the potential use of these methods as alternatives to expensive and time-consuming conventional techniques. We also highlight potential limitations that these probes may present when it comes to routine application. Finally we discuss possible future improvements to enhance the selectivity and robustness of these sensors. We note that there is still a need for researchers to develop standardized QD based sensors which could lead to their commercialization and routine application. - Highlights: • Application of quantum dots as fluorescence probes in pesticide detection. • Recognition elements and modification strategies towards selective pesticide detection. • Sensitive detection below regulatory limits in various matrices. • Challenges and possible solutions towards standardization of quantum dot based analytical methods.

  11. Fluorescence detection of pesticides using quantum dot materials – A review

    International Nuclear Information System (INIS)

    Nsibande, S.A.; Forbes, P.B.C.

    2016-01-01

    High pesticide use, especially in agriculture, can lead to environmental pollution and potentially adverse health effects. As result, pesticide residues end up in different media, including water and food products, which may serve as direct routes for human exposure. There is thus a continuous drive to develop analytical methods for screening and quantification of these compounds in the different environmental media in which they may occur. Development of quantum dot (QD) based sensors for monitoring pesticides has gained momentum in recent years. QD materials have excellent and unique optical properties and have high fluorescence quantum yields compared to other fluorophores. They have thus been used in numerous studies for the development of probes for organic pollutants. In this paper we specifically review their application as fluorescence probes for pesticide detection in different media including water and in fruits and vegetables. The low detection limits reported demonstrate the potential use of these methods as alternatives to expensive and time-consuming conventional techniques. We also highlight potential limitations that these probes may present when it comes to routine application. Finally we discuss possible future improvements to enhance the selectivity and robustness of these sensors. We note that there is still a need for researchers to develop standardized QD based sensors which could lead to their commercialization and routine application. - Highlights: • Application of quantum dots as fluorescence probes in pesticide detection. • Recognition elements and modification strategies towards selective pesticide detection. • Sensitive detection below regulatory limits in various matrices. • Challenges and possible solutions towards standardization of quantum dot based analytical methods.

  12. Transparent Electrode Materials for Simultaneous Amperometric Detection of Exocytosis and Fluorescence Microscopy.

    Science.gov (United States)

    Kisler, Kassandra; Kim, Brian N; Liu, Xin; Berberian, Khajak; Fang, Qinghua; Mathai, Cherian J; Gangopadhyay, Shubhra; Gillis, Kevin D; Lindau, Manfred

    2012-01-01

    We have developed and tested transparent microelectrode arrays capable of simultaneous amperometric measurement of oxidizable molecules and fluorescence imaging through the electrodes. Surface patterned microelectrodes were fabricated from three different conducting materials: Indium-tin-oxide (ITO), nitrogen-doped diamond-like carbon (DLC) deposited on top of ITO, or very thin (12-17 nm) gold films on glass substrates. Chromaffin cells loaded with lysotracker green or acridine orange dye were placed atop the electrodes and vesicle fluorescence imaged with total internal reflection fluorescence (TIRF) microscopy while catecholamine release from single vesicles was measured as amperometric spikes with the surface patterned electrodes. Electrodes fabricated from all three materials were capable of detecting amperometric signals with high resolution. Unexpectedly, amperometric spikes recorded with ITO electrodes had only about half the amplitude and about half as much charge as those detected with DLC or gold electrodes, indicating that the ITO electrodes are not as sensitive as gold or DLC electrodes for measurement of quantal catecholamine release. The lower sensitivity of ITO electrodes was confirmed by chronoamperometry measurements comparing the currents in the presence of different analytes with the different electrode materials.

  13. An Amidochlorin-Based Colorimetric Fluorescent Probe for Selective Cu2+ Detection

    Directory of Open Access Journals (Sweden)

    Wenting Li

    2016-01-01

    Full Text Available The design and synthesis of selective and sensitive chemosensors for the quantification of environmentally and biologically important ionic species has attracted widespread attention. Amidochlorin p6 (ACP; an effective colorimetric and fluorescent probe for copper ions (Cu2+ in aqueous solution derived from methyl pheophorbide-a (MPa was designed and synthesized. A remarkable color change from pale yellow to blue was easily observed by the naked eye upon addition of Cu2+; and a fluorescence quenching was also determined. The research of fluorescent quenching of ACP-Cu2+ complexation showed the detection limit was 7.5 × 10−8 mol/L; which suggested that ACP can act as a high sensitive probe for Cu2+ and can be used to quantitatively detect low levels of Cu2+ in aqueous solution. In aqueous solution the probe exhibits excellent selectivity and sensitivity toward Cu2+ ions over other metal ions (M = Zn2+; Ni2+; Ba2+; Ag+; Co2+; Na+; K+; Mg2+; Cd2+; Pb2+; Mn2+; Fe3+; and Ca2+. The obvious change from pale yellow to blue upon the addition of Cu2+ could make it a suitable “naked eye” indicator for Cu2+.

  14. Detection of fecal contamination on beef meat surfaces using handheld fluorescence imaging device (HFID)

    Science.gov (United States)

    Oh, Mirae; Lee, Hoonsoo; Cho, Hyunjeong; Moon, Sang-Ho; Kim, Eun-Kyung; Kim, Moon S.

    2016-05-01

    Current meat inspection in slaughter plants, for food safety and quality attributes including potential fecal contamination, is conducted through by visual examination human inspectors. A handheld fluorescence-based imaging device (HFID) was developed to be an assistive tool for human inspectors by highlighting contaminated food and food contact surfaces on a display monitor. It can be used under ambient lighting conditions in food processing plants. Critical components of the imaging device includes four 405-nm 10-W LEDs for fluorescence excitation, a charge-coupled device (CCD) camera, optical filter (670 nm used for this study), and Wi-Fi transmitter for broadcasting real-time video/images to monitoring devices such as smartphone and tablet. This study aimed to investigate the effectiveness of HFID in enhancing visual detection of fecal contamination on red meat, fat, and bone surfaces of beef under varying ambient luminous intensities (0, 10, 30, 50 and 70 foot-candles). Overall, diluted feces on fat, red meat and bone areas of beef surfaces were detectable in the 670-nm single-band fluorescence images when using the HFID under 0 to 50 foot-candle ambient lighting.

  15. In vitro study of caries detection through sound dentin using a laser fluorescence device, DIAGNOdent.

    Science.gov (United States)

    Iwami, Yukiteru; Shimizu, Ayako; Yamamoto, Hiroko; Hayashi, Mikako; Takeshige, Fumio; Ebisu, Shigeyuki

    2003-02-01

    The objective of this study was to investigate the feasibility of proximal surface caries detection using a laser fluorescence device, DIAGNOdent, through the sound dentin surrounding the cavity wall after removal of occlusal caries. Extracted sound human molars were ground to prepare horizontal and vertical dentin plates 1.4 mm thick. Extracted carious human molars were reduced in thickness horizontally from the occlusal surfaces until exposure of the dentin caries. The dentin plate was placed on the carious tooth. Before and after gradual thinning of the dentin plate from approximately 1.4 mm to 0.2 mm thick, the dentin caries was measured 10 times through the plate by the laser fluorescence device with a cone-shaped tip or a broad tip. When the dentin plate was reduced to less than 0.3 mm thick (using a combination of a horizontal plate and cone-shaped tip) or 0.2 mm thick (using the other combinations), the values measured with the laser fluorescence device were significantly larger than the values before reducing the thickness of the dentin. Based on these results, the device offers potential use as one of the screening tests for proximal surface caries detection through sound dentin when the sound dentin between tip and caries is thin.

  16. Fluorescent multiplex linkage analysis and carrier detection for Duchenne/Becker muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Schwartz, L.S.; Hoffman, E.P. (Univ. of Pittsburgh Schoool of Medicine, Pittsburgh, PA (United States)); Tarleton, J. (Self Memorial Hospital, Greenwood, SC (United States)); Popovich, B. (Children' s Hosptial and Health Center, San Diego, CA (United States)); Seltzer, W.K. (Univ. of Colorado Health Sciences Center, Denver, CO (United States))

    1992-10-01

    The authors have developed a fast and accurate PCR-based linkage and carrier detection protocol for families of Duchenne muscular dystrophy (DMD)/Becker muscular dystrophy (BMD) patients with or without detectable deletions of the dystrophin gene, using fluorescent PCR products analyzed on an automated sequencer. When a deletion is found in the affected male DMD/BMD patient by standard multiplex PCR, fluorescently labeled primers specific for the deleted and nondeleted exon(s) are used to amplify the DNA of at-risk female relatives by using multiplex PCR at low cycle number (20 cycles). The products are then quantitatively analyzed on an automatic sequencer to determine whether they are heterozygous for the deletion and thus are carriers. As a confirmation of the deletion data, and in cases in which a deletion is not found in the proband, fluorescent multiplex PCR linkage is done by using four previously described polymorphic dinucleotide sequences. The four (CA)[sub n] repeats are located throughout the dystrophin gene, making the analysis highly informative and accurate. The authors present the successful application of this protocol in families who proved refractory to more traditional analyses. 22 refs., 3 figs.

  17. Capillary electrophoresis hyphenated with UV-native-laser induced fluorescence detection (CE/UV-native-LIF).

    Science.gov (United States)

    Couderc, François; Ong-Meang, Varravaddheay; Poinsot, Véréna

    2017-01-01

    Native laser-induced fluorescence using UV lasers associated to CE offers now a large related literature, for now 30 years. The main works have been performed using very expensive Ar-ion lasers emitting at 257 and 275 nm. They are not affordable for routine analyses, but have numerous applications such as protein, catecholamine, and indolamine analysis. Some other lasers such as HeCd 325 nm have been used but only for few applications. Diode lasers, emitting at 266 nm, cheaper, are extensively used for the same topics, even if the obtained sensitivity is lower than the one observed using the costly UV-Ar-ion lasers. This review presents various CE or microchips applications and different UV lasers used for the excitation of native fluorescence. We showed that CE/Native UV laser induced fluorescence detection is very sensitive for detection as well as small aromatic biomolecules than proteins containing Trp and Tyr amino acids. Moreover, it is a simple way to analyze biomolecules without derivatization. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Fiber optic-based fluorescence detection system for in vivo studies of exogenous chromophore pharmacokinetics

    Science.gov (United States)

    Doiron, Daniel R.; Dunn, J. B.; Mitchell, W. L.; Dalton, Brian K.; Garbo, Greta M.; Warner, Jon A.

    1995-05-01

    The detection and quantification of the concentration of exogenous chromophores in-vivo by their fluorescence is complicated by many physical and geometrical parameters. Measurement of such signals is advantageous in determining the pharmacokinetics of photosensitizers such as those used in photodynamic therapy (PDT) or to assist in the diagnosis of tissue histological state. To overcome these difficulties a ratio based fiber optic contact fluorometer has been developed. This fluorescence detection system (FDS) uses the ratio of the fluorescence emission peak of the exogenous chromophore to that of endogenous chromophores, i.e. autofluorescence, to correct for a variety of parameters affecting the magnitude of the measured signals. By doing so it also minimizes the range of baseline measurements prior to exogenous drug injection, for various tissue types. Design of the FDS and results of its testing in animals and patients using the second generation photosensitizer Tin ethyletiopurpurin (SnET2) are presented. These results support the feasibility and usefulness of the Ratio FDS system.

  19. Laser-induced fluorescence detection platform for point-of-care testing

    Science.gov (United States)

    Berner, Marcel; Hilbig, Urs; Schubert, Markus B.; Gauglitz, Günter

    2017-08-01

    Point-of-care testing (POCT) devices for continuous low-cost monitoring of critical patient parameters require miniaturized and integrated setups for performing quick high-sensitivity analyses, away from central clinical laboratories. This work presents a novel and promising laser-induced fluorescence platform for measurements in direct optical test formats that leads towards such powerful POCT devices based on fluorescence-labeled immunoassays. Ultimate sensitivity of thin film photodetectors, integrated with microfluidics, and a comprehensive optimization of all system components aim at low-level signal detection in the targeted biosensor application. The setup acquires fluorescence signals from the volume of a microfluidic channel. An innovative sandwiching process forms a flow channel in the microfluidic chips by embedding laser-cut double-sided adhesive tapes. The custom fit of amorphous silicon based photodiode arrays to the geometry of the flow channel enables miniaturization, fully adequate for POCT devices. A free-beam laser excitation with line focus provides excellent alignment stability, allows for easy and reliable swapping of the disposable microfluidic chips, and therewith greatly improves the ease of use of the resulting integrated device. As a proof-of-concept of this novel in-volume measurement approach, the limit of detection for the dye DY636-COOH in pure water as a model fluorophore is examined and found to be 26 nmol l-1 .

  20. Sensitive and Selective Ratiometric Fluorescence Probes for Detection of Intracellular Endogenous Monoamine Oxidase A.

    Science.gov (United States)

    Wu, Xiaofeng; Li, Lihong; Shi, Wen; Gong, Qiuyu; Li, Xiaohua; Ma, Huimin

    2016-01-19

    Monoamine oxidase A (MAO-A) is known to widely exist in most cell lines in the body, and its dysfunction (unusually high or low levels of MAO-A) is thought to be responsible for several psychiatric and neurological disorders. Thus, a sensitive and selective method for evaluating the relative MAO-A levels in different live cells is urgently needed to better understand the function of MAO-A, but to our knowledge such a method is still lacking. Herein, we rationally design two new ratiometric fluorescence probes (1 and 2) that can sensitively and selectively detect MAO-A. The probes are constructed by incorporating a recognition group of propylamine into the fluorescent skeleton of 1,8-naphthalimide, and the detection mechanism is based on amine oxidation and β-elimination to release the fluorophore (4-hydroxy-N-butyl-1,8-naphthalimide), which is verified by HPLC analysis. Reaction of the probes with MAO-A produces a remarkable fluorescence change from blue to green, and the ratio of fluorescence intensity at 550 and 454 nm is directly proportional to the concentration of MAO-A in the ranges of 0.5-1.5 and 0.5-2.5 μg/mL with detection limits of 1.1 and 10 ng/mL (k = 3) for probes 1 and 2, respectively. Surprisingly, these probes show strong fluorescence responses to MAO-A but almost none to MAO-B (one of two isoforms of MAO), indicating superior ability to distinguish MAO-A from MAO-B. The high specificity of the probes for MAO-A over MAO-B is further supported by different inhibitor experiments. Moreover, probe 1 displays higher sensitivity than probe 2 and is thus investigated to image the relative MAO-A levels in different live cells, such as HeLa and NIH-3T3 cells. It is found that the concentration of endogenous MAO-A in HeLa cells is approximately 1.8 times higher than that in NIH-3T3 cells, which is validated by the result from an ELISA kit. Additionally, the proposed probes may find more uses in the specific detection of MAO-A between the two isoforms of MAO

  1. A conformation-induced fluorescence method for microRNA detection

    DEFF Research Database (Denmark)

    Aw, Sherry S; Tang, Melissa Xm; Teo, Yin Nah

    2016-01-01

    MicroRNAs play important roles in a large variety of biological systems and processes through their regulation of target mRNA expression, and show promise as clinical biomarkers. However, their small size presents challenges for tagging or direct detection. Innovation in techniques to sense...... and quantify microRNAs may aid research into novel aspects of microRNA biology and contribute to the development of diagnostics. By introducing an additional stem loop into the fluorescent RNA Spinach and altering its 3' and 5' ends, we have generated a new RNA, Pandan, that functions as the basis for a micro......RNA sensor. Pandan contains two sequence-variable stem loops that encode complementary sequence for a target microRNA of interest. In its sensor form, it requires the binding of a target microRNA in order to reconstitute the RNA scaffold for fluorophore binding and fluorescence. Binding of the target micro...

  2. Functionalization of Polymers with Fluorescent and Neutron Sensitive Groups for Efficient Neutron and Gamma Detection

    Science.gov (United States)

    Mahl, Adam; Yemam, Henok; Remedes, Tyler; Stuntz, Jack; Koldemir, Unsal; Sellinger, Alan; Greife, Uwe

    2015-10-01

    This presentation will review the efforts made by an interdisciplinary development project aimed at cost-effective, thermal neutron sensitive, plastic scintillators as part of the communities efforts towards replacing 3He based detectors. Colorado School of Mines researchers with backgrounds in Physics and Chemistry have worked on the incorporation of 10B in plastics through admixture of various commercial and novel dopants developed at CSM. In addition, new fluorescent dopants have been developed for plastic scintillators in an effort towards better understanding quenching effects and scintillator response to thermal neutrons via pulse shape discrimination methods. Results on transparent samples using fluorescent spectroscopy and gamma/neutron excitation will be presented. Funded via Department of Homeland Security - Domestic Nuclear Detection Office.

  3. Highly sensitive and selective fluorescent detection of cerebral lead(II) based on graphene quantum dot conjugates.

    Science.gov (United States)

    Qi, Yan-Xia; Zhang, Min; Fu, Qian-Qian; Liu, Ran; Shi, Guo-Yue

    2013-11-21

    A novel probe based on graphene quantum dot conjugates was developed for fluorescent detection of Pb(2+) (LOD: 9 pM) and furthermore for monitoring Pb(2+) in the striatum of rat, combined with microdialysis sampling in vivo.

  4. SERS and fluorescence-based ultrasensitive detection of mercury in water.

    Science.gov (United States)

    Makam, Pandeeswar; Shilpa, Rohilla; Kandjani, Ahmad Esmaielzadeh; Periasamy, Selvakannan R; Sabri, Ylias Mohammad; Madhu, Chilakapati; Bhargava, Suresh Kumar; Govindaraju, Thimmaiah

    2018-02-15

    The development of reliable and ultrasensitive detection marker for mercury ions (Hg 2+ ) in drinking water is of great interest for toxicology assessment, environmental protection and human health. Although many Hg 2+ detection methods have been developed, only few offer sensitivities below 1pM. Herein, we describe a simple histidine (H) conjugated perylene diimide (PDI) bolaamphiphile (HPH) as a dual-responsive optical marker to develop highly selective and sensitive probe as visible (sol-to-gel transformation), fluorescence and SERS-based Hg 2+ sensor platform in the water. Remarkably, HPH as a SERS marker supported on Au deposited monodispersed nanospheres monolayers (Au-MNM) of polystyrene offers an unprecedented selectivity and the best ever reported detection limit (LOD) of 60 attomolar (aM, 0.01 parts-per-quadrillion (ppq)) for Hg 2+ in water. This is ten orders of magnitude lower than the United States Environmental Protection Agency (USEPA) tolerance limit of Hg 2+ in drinking water (10nM, 2 ppb). This simple and effective design principle of host-guest interactions driven fluorescence and SERS-based detection may inspire the future molecular engineering strategies for the development of ultrasensitive toxic analyte sensor platforms. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. A sensitive fluorescence quenching method for the detection of tartrazine with acriflavine in soft drinks.

    Science.gov (United States)

    Yang, Huan; Ran, Guihua; Yan, Jingjing; Zhang, Hui; Hu, Xiaoli

    2018-03-01

    In this work, a simple, rapid, sensitive, selective spectrofluorimetric method was applied to detect tartrazine. The fluorescence of acriflavine could be efficiently quenched by tartrazine. The method manifested real time response as well as presented satisfied linear relationship to tartrazine. The linear response range of tartrazine (R 2 = 0.9995) was from 0.056 to 5 μmol L -1 . The detection limit (3σ/k) was 0.017 μmol L -1 , indicating that this method could be applied to detect traces of tartrazine. The accuracy and precision of the method was further assured by recovery studies via a standard addition method, with percentage recoveries in the range of 96.0% to 103.0%. Moreover, a quenching mechanism was investigated systematically by the linear plots at varying temperatures based on the Stern-Volmer equation, fluorescence lifetime and UV-visible absorption spectra, all of which proved to be static quenching. This sensitive, selective assay possessed a great application prospect for the food industry owing to its simplicity and rapidity for the detection of tartrazine. Copyright © 2017 John Wiley & Sons, Ltd.

  6. Intrinsic Tryptophan Fluorescence in the Detection and Analysis of Proteins: A Focus on Förster Resonance Energy Transfer Techniques

    Directory of Open Access Journals (Sweden)

    Amar B. T. Ghisaidoobe

    2014-12-01

    Full Text Available F resonance energy transfer (FRET occurs when the distance between a donor fluorophore and an acceptor is within 10 nm, and its application often necessitates fluorescent labeling of biological targets. However, covalent modification of biomolecules can inadvertently give rise to conformational and/or functional changes. This review describes the application of intrinsic protein fluorescence, predominantly derived from tryptophan (\\(\\uplambda_{\\textsc{ex}}\\sim\\ nm, \\(\\uplambda_{\\textsc{em}}\\sim\\ 350 nm, in protein-related research and mainly focuses on label-free FRET techniques. In terms of wavelength and intensity, tryptophan fluorescence is strongly influenced by its (or the proteinlocal environment, which, in addition to fluorescence quenching, has been applied to study protein conformational changes. Intrinsic F resonance energy transfer (iFRET, a recently developed technique, utilizes the intrinsic fluorescence of tryptophan in conjunction with target-specific fluorescent probes as FRET donors and acceptors, respectively, for real time detection of native proteins.

  7. Early detection of urothelial premalignant lesions using hexaminolevulinate fluorescence cystoscopy in high risk patients

    Directory of Open Access Journals (Sweden)

    Nespoli Luca

    2010-11-01

    Full Text Available Abstract Background To evaluate fluorescence cystoscopy with hexaminolevulinate (HAL in the early detection of dysplasia (DYS and carcinoma in situ (CIS in select high risk patients. Methods We selected 30 consecutive bladder cancer patients at high risk for progression. After endoscopic resection, all patients received (a induction BCG schedule when needed, and (b white light and fluorescence cystoscopy after 3 months. HAL at doses of 85 mg (GE Healthcare, Buckinghamshire, United Kingdom dissolved in 50 ml of solvent to obtain an 8 mmol/L solution was instilled intravesically with a 12 Fr catheter into an empty bladder and left for 90 minutes. The solution was freshly prepared immediately before instillation. Cystoscopy was performed within 120 minutes of bladder emptying. Standard and fluorescence cystoscopy was performed using a double light system (Combilight PDD light source 5133, Wolf, Germany which allowed an inspection under both white and blue light. Results The overall incidence was 43.3% dysplasia, 23.3% CIS, and 13.3% superficial transitional cell cancer. In 21 patients, HAL cystoscopy was positive with one or more fluorescent flat lesions. Of the positive cases, there were 4 CIS, 10 DYS, 2 association of CIS and DYS, 4 well-differentiated non-infiltrating bladder cancers, and 1 chronic cystitis. In 9 patients with negative HAL results, random biopsies showed 1 CIS and 1 DYS. HAL cystoscopy showed 90.1% sensitivity and 87.5% specificity with 95.2% positive predictive value and 77.8% negative predictive value. Conclusion Photodynamic diagnosis should be considered a very important tool in the diagnosis of potentially evolving flat lesions on the bladder mucosa such as DYS and CIS. Moreover, detection of dysplasic lesions that are considered precursors of CIS may play an important role in preventing disease progression. In our opinion, HAL cystoscopy should be recommended in the early follow-up of high risk patients.

  8. Development of graphite carbon nitride based fluorescent immune sensor for detection of alpha fetoprotein

    Science.gov (United States)

    Li, Yike; Dong, Lingyu; Wang, Xiangfeng; Liu, Yuan; Liu, Hailing; Xie, Mengxia

    2018-05-01

    A novel fluorescent immunosensor for determination of alpha fetoprotein (AFP) in serum samples has been developed based on the nano graphite carbon nitride (g-C3N4) as fluorophore and immunomagnetic beads (MBs) as separation material. The bulk g-C3N4 was obtained by thermal polymerization of melamine, and then carboxylated and exfoliated to acquire the carboxylated nano g-C3N4 (c-n-g-C3N4), which has been characterized and the results showed that it had excellent fluorescent properties. The antibodies of AFP (Ab1, Ab2) were conjugated to the MBs and the c-n-g-C3N4, respectively. In assay of AFP detection, the magnetic part of the immunosensor, MBs-Ab1, would form the sandwich type complex with the signal part of the sensor, c-n-g-C3N4-Ab2. The developed immunosensor could simplify the process of separation due to the MBs. The results illustrated that proposed approach held a good linearity between the fluorescence intensity of the sensor and the AFP concentration ranging from 5-600 ng/mL with the limit of detection as low as 0.43 ng/mL, and its spiking recoveries ranged from 98.2% to 105.9% with RSD from 2.1% to 3.5%. The fabricated fluorescent immunosensor possesses the merits of good sensitivity, excellent selectivity, high biocompatibility and low cost, and the results provide a novel clue to develop immunosensor for determination of the biomarkers in complex matrices.

  9. BODIPY-based azamacrocyclic ensemble for selective fluorescence detection and quantification of homocysteine in biological applications.

    Science.gov (United States)

    Li, Zan; Geng, Zhi-Rong; Zhang, Cui; Wang, Xiao-Bo; Wang, Zhi-Lin

    2015-10-15

    Considering the significant role of plasma homocysteine in physiological processes, two ensembles (F465-Cu(2+) and F508-Cu(2+)) were constructed based on a BODIPY (4,4-difluoro-1,3,5,7-tetramethyl-4-bora-3a,4a-diaza-s-indacene) scaffold conjugated with an azamacrocyclic (1,4,7-triazacyclononane and 1,4,7,10-tetraazacyclododecane) Cu(2+) complex. The results of this effort demonstrated that the F465-Cu(2+) ensemble could be employed to detect homocysteine in the presence of other biologically relevant species, including cysteine and glutathione, under physiological conditions with high selectivity and sensitivity in the turn-on fluorescence mode, while the F508-Cu(2+) ensemble showed no fluorescence responses toward biothiols. A possible mechanism for this homocysteine-specific specificity involving the formation of a homocysteine-induced six-membered ring sandwich structure was proposed and confirmed for the first time by time-dependent fluorescence spectra, ESI-MS and EPR. The detection limit of homocysteine in deproteinized human serum was calculated to be 241.4 nM with a linear range of 0-90.0 μM and the detection limit of F465 for Cu(2+) is 74.7 nM with a linear range of 0-6.0 μM (F508, 80.2 nM, 0-7.0 μM). We have demonstrated the application of the F465-Cu(2+) ensemble for detecting homocysteine in human serum and monitoring the activity of cystathionine β-synthase in vitro. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Rapid detection of authenticity and adulteration of walnut oil by FTIR and fluorescence spectroscopy: a comparative study.

    Science.gov (United States)

    Li, Bingning; Wang, Haixia; Zhao, Qiaojiao; Ouyang, Jie; Wu, Yanwen

    2015-08-15

    Fourier transform infrared (FTIR) and fluorescence spectroscopy combined with soft independent modeling of class analogies (SIMCA) and partial least square (PLS) were used to detect the authenticity of walnut oil and adulteration amount of soybean oil in walnut oil. A SIMCA model of FTIR spectra could differentiate walnut oil and other oils into separate categories; the classification limit of soybean oil in walnut oil was 10%. Fluorescence spectroscopy could differentiate oil composition by the peak position and intensity of emission spectrum without multivariate analysis. The classification limit of soybean oil adulterated in walnut oil by fluorescence spectroscopy was below 5%. The deviation of the prediction model for fluorescence spectra was lower than that for FTIR spectra. Fluorescence spectroscopy was more applicable than FTIR in the adulteration detection of walnut oil, both from the determination limit and prediction deviation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Proximity-dependent protein detection based on enzyme-assisted fluorescence signal amplification.

    Science.gov (United States)

    Tan, Yuyu; Guo, Qiuping; Zhao, Xiayu; Yang, Xiaohai; Wang, Kemin; Huang, Jin; Zhou, Yu

    2014-01-15

    In this paper, we develop a sensitive fluorescence method for protein detection based on proximity extension and enzyme-assisted signal amplification. In this novel method, pairs of proximity probes are designed, and the recognition elements are integrated into the proximity probes. Then proteins are detected by transforming aptamer or antibody-protein binding signals into DNA detection based on proximity effect. In addition, nick sites are introduced into the proximity probes to amplify the detectable signal. As proof of concept, detection of human α-thrombin and human IgG are demonstrated in this study. The aptamers and antibodies are coupled in the proximity probes as recognition elements for human α-thrombin and human IgG respectively. In the presence of target protein, aptamer or antibody-protein binding signals are transformed into detectable signals by the proximity effect, and can be further amplified by enzyme-assisted strand displacement. The above mentioned strategies consequently bring the limit of detection (LOD) to as low as 1 pM for human α-thrombin and 6 pM for human IgG. Furthermore, this method might be extended to sensitive detection of other proteins by changing recognition elements of proximity probes. © 2013 Elsevier B.V. All rights reserved.

  12. Association between the cariogenicity of a dental microcosm biofilm and its red fluorescence detected by Quantitative Light-induced Fluorescence-Digital (QLF-D).

    Science.gov (United States)

    Lee, Eun-Song; Kang, Si-Mook; Ko, Hae-Youn; Kwon, Ho-Keun; Kim, Baek-Il

    2013-12-01

    This study evaluated whether Quantitative Light-induced Fluorescence-Digital (QLF-D) can detect the levels of cariogenicity of dental microcosm biofilms by assessing the red fluorescence intensity. Dental microcosm biofilms were initiated from human saliva on bovine enamel discs. Biofilms with various levels of cariogenicity were then grown in artificial saliva supplemented with sucrose at different concentrations (0.05%, 0.1%, 0.2%, and 0.5%) in 24-well microplates. After 10 days, fluorescence images of the biofilms were captured by the QLF-D to analyse the red fluorescence intensity, which was quantified as the red/green ratio (R/G value). The supernatant pH was also measured, as well as the total and aciduric bacteria counts of the collected biofilms. Mineral loss in enamel was also evaluated by calculating the percentage of surface microhardness changes (%SHC). The R/G values of the biofilms differed significantly with the sucrose concentration (pdental microcosm biofilms in vitro, which indicates that this device can be used to detect the levels of cariogenicity of a dental biofilm. The QLF-D is able to assess the cariogenic levels of dental plaque based on the intensity of red fluorescence. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Highly sensitive rapid fluorescence detection of protein residues on surgical instruments

    Energy Technology Data Exchange (ETDEWEB)

    Kovalev, Valeri I [School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Bartona, James S [School of Engineering and Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS (United Kingdom); Richardson, Patricia R [School of Chemistry, University of Edinburgh, Edinburgh, EH9 3JJ (United Kingdom); Jones, Anita C [School of Chemistry, University of Edinburgh, Edinburgh, EH9 3JJ (United Kingdom)

    2006-07-15

    There is a risk of contamination of surgical instruments by infectious protein residues, in particular, prions which are the agents for Creutzfeldt-Jakob Disease in humans. They are exceptionally resistant to conventional sterilization, therefore it is important to detect their presence as contaminants so that alternative cleaning procedures can be applied. We describe the development of an optimized detection system for fluorescently labelled protein, suitable for in-hospital use. We show that under optimum conditions the technique can detect {approx}10 attomole/cm{sup 2} with a scan speed of {approx}3-10 cm{sup 2}/s of the test instrument's surface. A theoretical analysis and experimental measurements will be discussed.

  14. DNA-functionalized gold nanoparticle-based fluorescence polarization for the sensitive detection of silver ions.

    Science.gov (United States)

    Wang, Gongke; Wang, Shuangli; Yan, Changling; Bai, Guangyue; Liu, Yufang

    2018-04-05

    Despite their practical applications, Ag + ions are environmental pollutants and affect human health. So the effective detection methods of Ag + ions are imperative. Herein, we developed a simple, sensitive, selective, and cost-effective fluorescence polarization sensor for Ag + detection in aqueous solution using thiol-DNA-functionalized gold nanoparticles (AuNPs). In this sensing strategy, Ag + ions can specifically interact with a cytosine-cytosine (CC) mismatch in DNA duplexes and form stable metal-mediated cytosine-Ag + -cytosine (C-Ag + -C) base pairs. The formation of the C-Ag + -C complex results in evident changes in the molecular volume and fluorescence polarization signal. To achieve our aims, we prepared two complementary DNA strands containing C-base mismatches (probe A: 5'-SH-A 10 -TACCACTCCTCAC-3' and probe B: 5'-TCCTCACCAGTCCTA-FAM-3'). The stable hybridization between probe A and probe B occurs with the formation of the C-Ag + -C complex in the presence of Ag + ions, leading to obvious fluorescence quenching in comparison to the system without AuNP enhancement. The assay can be used to identify nanomolar levels of Ag + within 6 min at room temperature, and has extremely high specificity for Ag + , even in the presence of higher concentrations of interfering metal ions. Furthermore, the sensor was successfully applied to the detection of Ag + ions in environmental water samples and showed excellent selectivity and high sensitivity, implying its promising application in the future. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Comparison of laser fluorescence devices for detection of caries in primary teeth.

    Science.gov (United States)

    Cınar, Cağdaş; Atabek, Didem; Odabaş, Mesut E; Olmez, Ayşegül

    2013-04-01

    The aim of this in vivo study was to evaluate the performance of fluorescence-based devices in detecting occlusal caries lesions in primary molars compared with conventional methods. Two examiners assessed 44 occlusal surfaces of first and second primary molars in 20 patients using two fluorescence devices: DIAGNOdent (LF) and DIAGNOdent pen (LFpen). Teeth were also assessed by visual examination and bitewing radiograph. Histological examination served as the gold standard after extraction. By using the McNemar test, the sensitivity, specificity, accuracy, and area under the receiver operating curve were calculated as outer enamel (D1), inner enamel (D2) and dentine caries (D3) lesion thresholds. The intra- and inter-examiner reproducibility were calculated using the Cohen's unweighted kappa statistics. At the D1 threshold, the LFpen sensitivity was statistically higher than LF and radiographic examination (P 0.05). All methods demonstrated the highest sensitivity values at D3. At the D1 and D2 thresholds, there were no significant differences between the LFpen specificity and the other methods. All methods presented similar performance in detecting all lesions considering the area under the receiver operating curve. The LFpen showed better performance than LF. Furthermore, visual examination and the LFpen device seem to be sufficient for detection of occlusal caries in primary molars. © 2013 FDI World Dental Federation.

  16. Highly sensitive immunoassay of protein molecules based on single nanoparticle fluorescence detection in a nanowell

    Science.gov (United States)

    Han, Jin-Hee; Kim, Hee-Joo; Lakshmana, Sudheendra; Gee, Shirley J.; Hammock, Bruce D.; Kennedy, Ian M.

    2011-03-01

    A nanoarray based-single molecule detection system was developed for detecting proteins with extremely high sensitivity. The nanoarray was able to effectively trap nanoparticles conjugated with biological sample into nanowells by integrating with an electrophoretic particle entrapment system (EPES). The nanoarray/EPES is superior to other biosensor using immunoassays in terms of saving the amounts of biological solution and enhancing kinetics of antibody binding due to reduced steric hindrance from the neighboring biological molecules. The nanoarray patterned onto a layer of PMMA and LOL on conductive and transparent indium tin oxide (ITO)-glass slide by using e-beam lithography. The suspension of 500 nm-fluorescent (green emission)-carboxylated polystyrene (PS) particles coated with protein-A followed by BDE 47 polyclonal antibody was added to the chip that was connected to the positive voltage. The droplet was covered by another ITO-coated-glass slide and connected to a ground terminal. After trapping the particles into the nanowells, the solution of different concentrations of anti-rabbit- IgG labeled with Alexa 532 was added for an immunoassay. A single molecule detection system could quantify the anti-rabbit IgG down to atto-mole level by counting photons emitted from the fluorescent dye bound to a single nanoparticle in a nanowell.

  17. Highly Sensitive and Miniaturized Fluorescence Detection System with an Autonomous Capillary Fluid Manipulation Chip

    Directory of Open Access Journals (Sweden)

    Ji Fang

    2012-05-01

    Full Text Available This paper presents a novel, highly sensitive and ultra-small fluorescent detection system, including an autonomous capillary fluid manipulation chip. The optical detector integrates a LED light source, all necessary optical components, and a photodiode with preamplifier into one package of about 2 cm × 2 cm × 2 cm. Also, the low-cost and simple pumpless microfluidic device works well in sample preparation and manipulation. This chip consists of capillary stop valves and trigger valves which are fabricated by lithography and then bonded with a polydimethylsiloxane-ethylene oxide polymer polydimethylsiloxane (PEO-PDMS cover. The contact angle of the PEO-PDMS can be adjusted by changing the concentration of the PEO. Hence, the fluidic chip can achieve functionalities such as timing features and basic logical functions. The prototype has been tested by fluorescence dye 5-Carboxyfluorescein (5-FAM dissolved into the solvent DMSO (Dimethyl Sulfoxide. The results prove a remarkable sensitivity at a pico-scale molar, around 1.08 pM. The low-cost and miniaturized optical detection system, with a self-control capillary-driven microfluidic chip developed in this work, can be used as the crucial parts in portable biochemical detection applications and point of care testing.

  18. Simple, rapid and inexpensive quantitative fluorescent PCR method for detection of microdeletion and microduplication syndromes.

    Directory of Open Access Journals (Sweden)

    Martin Stofanko

    Full Text Available Because of economic limitations, the cost-effective diagnosis of patients affected with rare microdeletion or microduplication syndromes is a challenge in developing countries. Here we report a sensitive, rapid, and affordable detection method that we have called Microdeletion/Microduplication Quantitative Fluorescent PCR (MQF-PCR. Our procedure is based on the finding of genomic regions with high homology to segments of the critical microdeletion/microduplication region. PCR amplification of both using the same primer pair, establishes competitive kinetics and relative quantification of amplicons, as happens in microsatellite-based Quantitative Fluorescence PCR. We used patients with two common microdeletion syndromes, the Williams-Beuren syndrome (7q11.23 microdeletion and the 22q11.2 microdeletion syndromes and discovered that MQF-PCR could detect both with 100% sensitivity and 100% specificity. Additionally, we demonstrated that the same principle could be reliably used for detection of microduplication syndromes, by using patients with the Lubs (MECP2 duplication syndrome and the 17q11.2 microduplication involving the NF1 gene. We propose that MQF-PCR is a useful procedure for laboratory confirmation of the clinical diagnosis of microdeletion/microduplication syndromes, ideally suited for use in developing countries, but having general applicability as well.

  19. Assessing the Performance of the Laser Fluorescence Technique in Detecting Proximal Caries Cavities

    Directory of Open Access Journals (Sweden)

    Majid Akbari

    Full Text Available Introduction: Diagnosing the necessity of cavity preparation and restoration in demineralized proximal areas is always considered as a challenge in restorative treatment planning. The purpose of this study was to assess the performance of the laser fluorescence (LF technique in detection of proximal cavities.Materials & Methods: In this clinical trial, 44 proximal surfaces in 38 dental students were evaluated. The selected patients had radiolucent proximal lesions restricted to inner half of enamel or outer third of dentine in bitewing radiographs (BW. DIAGNOdent pen (LF pen device was used to determine the presence or absence of caries cavities in suspected proximal surfaces. Orthodontic elastic separators were then placed in the contact areas to provide enough space for direct visual and tactile examination. The sensitivity, specificity and accuracy of the laser fluorescence technique were calculated versus the reference standard. The ROC curve was drawn and the best cut-off to determine the presence or absence of proximal cavities was determined.Results: Using DIAGNOdent pen, the optimal cut-off for detecting proximal cavities was 18. The sensitivity, specificity and accuracy of DIAGNOdent pen for diagnosing proximal caries cavities were 100 per cent, 97.3 per cent and 97.7 per cent, respectively. Conclusion: Due to the high diagnostic accuracy of DIAGNOdent pen in detecting proximal caries cavities, it can be used as a valuable supplement in restorative treatment planning.

  20. Fluorescent method for detection of cleaved collagens using O-phthaldialdehyde (OPA).

    Science.gov (United States)

    Go, Katrina; Horikawa, Yousuke; Garcia, Ricardo; Villarreal, Francisco J

    2008-04-24

    Analysis of collagen degradation remains an important but cumbersome task. Traditional methods with dansyl chloride derivatization of collagen have been used to quantify collagen damage. Fluorescent labeling reagents have been developed that offer advantages such as greater solubility in water and low background emission. One such reagent is o-phthalaldehyde (OPA). In this study, we used OPA as a means of detecting small amounts of degraded collagen. Collagen samples isolated from skin or heart were used for OPA conjugation to exposed amino termini ("opalation"). Experiments utilizing small samples aliquoted in microtiter plates were performed to evaluate effects of increasing concentrations of OPA, varying concentrations of collagen, and effects of matrix metalloproteinase (MMP) digestion. Results indicate that within 10 min of reaction, OPA can be used to detect relative differences in cleaved vs. uncleaved collagen from skin or heart. Heart samples obtained from regions of high MMP activity correlated with increased OPA fluorescence relative to tissue with lower MMP activity. On the basis of these results, we conclude that OPA has valuable practical advantages for analytical use in detecting cleaved collagen in small tissue samples.

  1. A simple dental caries detection system using full spectrum of laser-induced fluorescence

    Science.gov (United States)

    Rocha-Cabral, Renata Maciel; Mendes, Fausto Medeiros; Maldonado, Edison Puig; Zezell, Denise Maria

    2015-06-01

    Objectives: to develop an apparatus for the detection of early caries lesions in enamel using the full extent of the tooth fluorescence spectrum, through the integration of a laser diode, fiber optics, filters and one portable spectrometer connected to a computer, all commercially available; to evaluate the developed device in clinical and laboratory tests, and compare its performance with commercial equipment. Methods: clinical examinations were performed in patients with indication for exodontics of premolars. After examinations, the patients underwent surgery and the teeth were stored individually. The optical measurements were repeated approximately two months after extraction, on the same sites previously examined, then histological analysis was carried out. Results: the spectral detector has presented high specificity and moderate sensitivity when applied to differentiate between healthy and damaged tissues, with no significant differences from the performance of the commercial equipment. The developed device is able to detect initial damages in enamel, with depth of approximately 300 μm. Conclusions: we successfully demonstrated the development of a simple and portable system based in laser-induced fluorescence for caries detection, assembled from common commercial parts. As the spectral detector acquires a complete recording of the spectrum from each tissue, it is possible to use it for monitoring developments of caries lesions.

  2. Detection of vegetation LUE based on chlorophyll fluorescence separation algorithm from Fraunhofer line

    Science.gov (United States)

    Liu, Liangyun; Zhang, Bing

    2009-09-01

    Photosynthetic efficiency is very important, and not yet generally assessable by remote sensing. Much research has proved the possibility of the separation of solar-induced chlorophyll fluorescence (ChlF) from the reflected hyperspectral data. As the 'probe' of plant photosynthesis, it is possible to detect photosynthetic light use efficiency (LUE) by the separated solar-induced ChlF. A diurnal experiment was carried out on winter wheat on Apr. 18, 2008, and the canopy radiance spectra and leaf LUE data were measured synchronously. The solar-induced chlorophyll fluorescence signals at 760nm and 688nm were separated from the reflected radiance spectral based on Fraunhofer lines in two oxygen absorption bands. The result showed that LUE was negatively correlated to the separated chlorophyll signals. The statistical models for LUE based on the solar-induced chlorophyll fluorescence values at 688 nm and 760 nm bands had correlation coefficients (R2) of 0.64 and 0.78, respectively. In addition, photochemical reflectance index (PRI) was also linked to LUE, and a statistical model for LUE based on PRI has a correlation coefficient (R2) of 0.66. The presented method provides a novel solution for monitoring LUE from remote sensing data.

  3. Detection of wood cell wall porosity using small carbohydrate molecules and confocal fluorescence microscopy.

    Science.gov (United States)

    Donaldson, L A; Kroese, H W; Hill, S J; Franich, R A

    2015-09-01

    A novel approach to nanoscale detection of cell wall porosity using confocal fluorescence microscopy is described. Infiltration of cell walls with a range of nitrophenyl-substituted carbohydrates of different molecular weights was assessed by measuring changes in the intensity of lignin fluorescence, in response to the quenching effect of the 4-nitrophenyl group. The following carbohydrates were used in order of increasing molecular weight; 4-nitrophenyl β-D-glucopyrano-side (monosaccharide), 4-nitrophenyl β-D-lactopyranoside (disaccharide), 2-chloro-4-nitrophenyl β-D-maltotrioside (trisaccharide), and 4-nitrophenyl α-D-maltopentaoside (pentasaccharide). This technique was used to compare cell wall porosity in wood which had been dewatered to 40% moisture content using supercritical CO2, where cell walls remain fully hydrated, with kiln dried wood equilibrated to 12% moisture content. Infiltration of cell walls as measured by fluorescence quenching, was found to decrease with increasing molecular weight, with the pentasaccharide being significantly excluded compared to the monosaccharide. Porosity experiments were performed on blocks and sections to assess differences in cell wall accessibility. Dewatered and kiln dried wood infiltrated as blocks showed similar results, but greater infiltration was achieved by using sections, indicating that not all pores were easily accessible by infiltration from the lumen surface. In wood blocks infiltrated with 4-nitrophenyl α-D-maltopentaoside, quenching of the secondary wall was quite variable, especially in kiln dried wood, indicating limited connectivity of pores accessible from the lumen surface. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  4. Assessment of variable fluorescence fluorometry as an approach for rapidly detecting living photoautotrophs in ballast water

    Science.gov (United States)

    First, Matthew R.; Robbins-Wamsley, Stephanie H.; Riley, Scott C.; Drake, Lisa A.

    2018-03-01

    Variable fluorescence fluorometry, an analytical approach that estimates the fluorescence yield of chlorophyll a (F0, a proximal measure of algal concentration) and photochemical yield (FV/FM, an indicator of the physiological status of algae) was evaluated as a means to rapidly assess photoautotrophs. Specifically, it was used to gauge the efficacy of ballast water treatment designed to reduce the transport and delivery of potentially invasive organisms. A phytoflagellate, Tetraselmis spp. (10-12 μm) and mixed communities of ambient protists were examined in both laboratory experiments and large-scale field trials simulating 5-d hold times in mock ballast tanks. In laboratory incubations, ambient organisms held in the dark exhibited declining F0 and FV/FM measurements relative to organisms held under lighted conditions. In field experiments, increases and decreases in F0 and FV/FM over the tank hold time corresponded to those of microscope counts of organisms in two of three trials. In the third trial, concentrations of organisms ≥ 10 and light-limited ballast tanks, would not be detected via variable fluorescence fluorometry, however.

  5. [Commercial orange juice beverages detection by fluorescence spectroscopy combined with PCA-ED and PLSR methods].

    Science.gov (United States)

    Hu, Yang-jun; Zhu, Chun; Chen, Guo-qing; Zhang, Yong; Kong, Fan-biao; Li, Run; Zhu, Zhuo-wei; Wang, Xu; Gao, Shu-mei

    2014-08-01

    In order to classify the orange juiice beverages effectively, the fluorescence character differences of two kinds of orange juice beverages including 100% orange juice and orange drink were analyzed and compared, principal component analysis combined with Euclidean distance was adopted to classify two kinds of orange juice beverages, and ideal classification results were obtained. Meanwhile, the orange juice content estimation model was established by using fluorescence spectroscopy combined with partial least squares regression method, and the correlation coefficient R, root mean square error of calibration RMSEC and root mean square error of prediction RMSEP were 0.997, 0.87% and 2.05%, respectively. The experimental results indicate that the calibration model offers comparatively accurate content estimation, which reflect the actual orange juice content in the commercial orange juice beverages. The exploration to classify orange juice beverages was carried out from two aspects of qualitative and quantitative analysis by employing fluorescence spectroscopy combined with chemometrics method, which can provide a new idea for the classification and adulteration detection of commercial orange juice beverages, and also can give certain reference basis for the quality control of orange juice raw material.

  6. Liquid chromatographic determination with fluorescence detection of B6 vitamers and riboflavin in milk and pharmaceuticals

    International Nuclear Information System (INIS)

    Gatti, R.; Gioia, M.G.

    2005-01-01

    A simple, reliable and selective high performance liquid chromatographic method with fluorescence detection at different programmed wavelengths has been developed for the simultaneous analysis of B 6 vitamers (pyridoxal 5'-phosphate, 4-pyridoxic acid, pyridoxal, pyridoxine and pyridoxamine) and Vitamin B 2 in commercial vitaminized milk and in woman milk. The chromatographic separations were performed on a reversed phase octyl column by using a mobile phase consisting of sodium pentanesulfonate in 1% acetic acid-methanol-tetrahydrofuran under gradient elution conditions. The fluorescence intensity of pyridoxal 5'-phosphate was enhanced by post-column photochemical conversion, giving significantly different fluorescence spectra by a on-line photoreactor switched OFF and ON under irradiation at 254 nm. In addition, a simple and rapid method in isocratic conditions without the need of photochemical conversion was proposed for the analysis of Vitamin B 6 and Vitamin B 2 in pharmaceuticals. Linearity, precision, recovery, selectivity and sensitivity were found satisfactory for each analysed compound. Quantitation limits ranged from 26 to 240 fmol

  7. A Fluorescent Probe for Detecting Mycobacterium tuberculosis and Identifying Genes Critical for Cell Entry

    Science.gov (United States)

    Yang, Dong; Ding, Feng; Mitachi, Katsuhiko; Kurosu, Michio; Lee, Richard E.; Kong, Ying

    2016-01-01

    The conventional method for quantitating Mycobacterium tuberculosis (Mtb) in vitro and in vivo relies on bacterial colony forming unit (CFU) enumeration on agar plates. Due to the slow growth rate of Mtb, it takes 3–6 weeks to observe visible colonies on agar plates. Imaging technologies that are capable of quickly quantitating both active and dormant tubercle bacilli in vitro and in vivo would accelerate research toward the development of anti-TB chemotherapies and vaccines. We have developed a fluorescent probe that can directly label the Mtb cell wall components. The fluorescent probe, designated as DLF-1, has a strong affinity to the D-Ala-D-Ala unit of the late peptidoglycan intermediates in the bacterial cell wall. We demonstrate that DLF-1 is capable of detecting Mtb in both the actively replicating and dormant states in vitro at 100 nM without inhibiting bacterial growth. The DLF-1 fluorescence signal correlated well with CFU of the labeled bacteria (R2 = 1 and 0.99 for actively replicating and dormant Mtb, respectively). DLF-1 can also quantitate labeled Mtb inside of cells. The utility of DLF-1 probe to quantitate Mtb was successfully applied to identify genes critical for cell invasion. In conclusion, this novel near infrared imaging probe provides a powerful new tool for enumerating Mtb with potential future use in bacterial virulence study. PMID:28066347

  8. A Fluorescent Probe for Detecting Mycobacterium tuberculosis and Identifying Genes Critical for Cell Entry

    Directory of Open Access Journals (Sweden)

    Dong Yang

    2016-12-01

    Full Text Available ABSTRACTThe conventional method for quantitating Mycobacterium tuberculosis (Mtb in vitro and in vivo relies on bacterial colony forming unit (CFU enumeration on agar plates. Due to the slow growth rate of Mtb, it takes 3-6 weeks to observe visible colonies on agar plates. Imaging technologies that are capable of quickly quantitating both active and dormant tubercle bacilli in vitro and in vivo would accelerate research towards the development of anti-TB chemotherapies and vaccines. We have developed a fluorescent probe that can directly label the Mtb cell wall components. The fluorescent probe, designated as DLF-1, has a strong affinity to the D-Ala-D-Ala unit of the late peptidoglycan intermediates in the bacterial cell wall. We demonstrate that DLF-1 is capable of detecting Mtb in both the active replicating and dormant states in vitro at 100 nM without inhibiting bacterial growth. The DLF-1 fluorescence signal correlated well with CFU of the labeled bacteria (R2=1 and 0.99 for active replicating and dormant Mtb, respectively. DLF-1 can also quantitate labeled Mtb inside of cells. The utility of DLF-1 probe to quantitate Mtb was also successfully applied to identify genes critical for cell invasion. In conclusion, this novel near infrared imaging probe provides a powerful new tool for enumerating Mtb with potential future use in bacterial virulence study.

  9. Bioprobes Based on Aptamer and Silica Fluorescent Nanoparticles for Bacteria Salmonella typhimurium Detection

    Science.gov (United States)

    Wang, Qiu-Yue; Kang, Yan-Jun

    2016-03-01

    In this study, we have developed an efficient method based on single-stranded DNA (ssDNA) aptamers along with silica fluorescence nanoparticles for bacteria Salmonella typhimurium detection. Carboxyl-modified Tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate (RuBPY)-doped silica nanoparticles (COOH-FSiNPs) were prepared using reverse microemulsion method, and the streptavidin was conjugated to the surface of the prepared COOH-FSiNPs. The bacteria S. typhimurium was incubated with a specific ssDNA biotin-labeled aptamer, and then the aptamer-bacteria conjugates were treated with the synthetic streptavidin-conjugated silica fluorescence nanoprobes (SA-FSiNPs). The results under fluorescence microscopy show that SA-FSiNPs can be applied effectively for the labeling of bacteria S. typhimurium with great photostable property. To further verify the specificity of SA-FSiNPs out of multiple bacterial conditions, variant concentrations of bacteria mixtures composed of bacteria S. typhimurium, Escherichia coli, and Bacillus subtilis were treated with SA-FSiNPs.

  10. Pancreatic tumor detection using hypericin-based fluorescence spectroscopy and cytology

    Science.gov (United States)

    Lavu, Harish; Geary, Kevin; Fetterman, Harold R.; Saxton, Romaine E.

    2005-04-01

    Hypericin is a novel, highly fluorescent photosensitizer that exhibits selective tumor cell uptake properties and is particularly resistant to photobleaching. In this study, we have characterized hypericin uptake in human pancreatic tumor cells with relation to incubation time, cell number, and drug concentration. Ex vivo hypericin based fluorescence spectroscopy was performed to detect the presence of MIA PaCa-2 pancreatic tumor cells in the peritoneal cavity of BALB/c nude mice, as well as to quantify gross tumor burden. Hypericin based cytology of peritoneal lavage samples, using both one and two photon laser confocal microscopy, demonstrated more than a two-fold increase in fluorescence emission of pancreatic tumor cells as compared to control samples. In vitro treatment of pancreatic cancer cells with hypericin based photodynamic therapy showed tumor cell cytotoxicity in a drug dose, incident laser power, and time dependent manner. For these experiments, a continuous wavelength solid-state laser source (532 nm) was operated at power levels in the range of 100-400 mW. Potential applications of hypericin in tumor diagnosis, staging, and therapy will be presented.

  11. Fluorescent gel particles in the nanometer range for detection of metabolites in living cells

    DEFF Research Database (Denmark)

    Almdal, K.; Sun, H.; Poulsen, A.K.

    2006-01-01

    In this present work a research program that aims at the development of sensor particles based on ratiometric detection of fluorescence from two dyes was embarked on. Such particles can in principle be used to achieve spatially and time resolved measurements of metabolite concentrations in living...... micelles in oil microemulsions. Typical sizes of the particles are tens of nanometers. Characterization methods for such particles based on size exclusion chromatography, photon correlation spectroscopy, scanning electron microscopy, and atomic force microscopy have been developed. The stability...

  12. Detection of orange juice frauds using front-face fluorescence spectroscopy and Independent Components Analysis.

    Science.gov (United States)

    Ammari, Faten; Redjdal, Lamia; Rutledge, Douglas N

    2015-02-01

    The aim of this study was to find simple objective analytical methods to assess the adulteration of orange juice by grapefruit juice. The adulterations by addition of grapefruit juice were studied by 3D-front-face fluorescence spectroscopy followed by Independent Components Analysis (ICA) and by classical methods such as free radical scavenging activity and total flavonoid content. The results of this study clearly indicate that frauds by adding grapefruit juice to orange juice can be detected at percentages as low as 1%. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Flame Front Detection Using Formaldehyde Laser Induced Fluorescence In Turbulent Lean Premixed Flames

    Energy Technology Data Exchange (ETDEWEB)

    Schenker, S.; Tylli, N.; Bombach, R.

    2005-03-01

    The present work aims at suggesting the excitation-detection scheme best suited for laser-induced fluorescence measurements of formaldehyde in turbulent lean premixed flames. In the literature, three different excitation schemes within the A{sup 1} X{sup 1} electronic transition have been suggested, with excitation into the 2{sup 1}{sub 0} 4{sup 1}{sub 0} , 4{sup 1}{sub 0} , and 4{sup 0}{sub 1} vibratoric bands, respectively. These excitation schemes were tested systematically and both advantages and disadvantages for each scheme are discussed. (author)

  14. Simplified sheath flow cuvette design for ultrasensitive laser induced fluorescence detection in capillary electrophoresis.

    Science.gov (United States)

    Dada, Oluwatosin O; Huge, Bonnie J; Dovichi, Norman J

    2012-07-07

    We present a design for a sheath-flow cuvette that uses a relatively inexpensive quartz cuvette. The cuvette has a high optical quality square flow chamber that is fused to quartz tubes at each end. PEEK/TEFZEL fittings hold and seal the quartz flow chamber without putting strain on the cuvette. The performance of the cuvette is evaluated as a laser-induced fluorescence detector for capillary electrophoresis. The cuvette produces mass detection limits of 50 yoctomoles (30 copies) for 5-carboxyl tetramethylrhodamine (5 TAMRA SE) with a separation efficiency of 400,000 theoretical plates.

  15. Reaction rate constant of HO2+O3 measured by detecting HO2 from photofragment fluorescence

    Science.gov (United States)

    Manzanares, E. R.; Suto, Masako; Lee, Long C.; Coffey, Dewitt, Jr.

    1986-01-01

    A room-temperature discharge-flow system investigation of the rate constant for the reaction 'HO2 + O3 yields OH + 2O2' has detected HO2 through the OH(A-X) fluorescence produced by photodissociative excitation of HO2 at 147 nm. A reaction rate constant of 1.9 + or - 0.3 x 10 to the -15th cu cm/molecule per sec is obtained from first-order decay of HO2 in excess O3; this agrees well with published data.

  16. Surface extended x-ray absorption fine structure of low-Z absorbates using fluorescence detection

    International Nuclear Information System (INIS)

    Stoehr, J.; Kollin, E.B.; Fischer, D.A.; Hastings, J.B.; Zaera, F.; Sette, F.

    1985-05-01

    Comparison of x-ray fluorescence yield (FY) and electron yield surface extended x-ray absorption fine structure spectra above the S K-edge for c(2 x 2) S on Ni(100) reveals an order of magnitude higher sensitivity of the FY technique. Using FY detection, thiophene (C 4 H 4 S) chemisorption on Ni(100) is studied with S coverages down to 0.08 monolayer. The molecule dissociates at temperatures as low as 100K by interaction with fourfold hollow Ni sites. Blocking of these sites by oxygen leaves the molecule intact

  17. Smartphone Cortex Controlled Real-Time Image Processing and Reprocessing for Concentration Independent LED Induced Fluorescence Detection in Capillary Electrophoresis.

    Science.gov (United States)

    Szarka, Mate; Guttman, Andras

    2017-10-17

    We present the application of a smartphone anatomy based technology in the field of liquid phase bioseparations, particularly in capillary electrophoresis. A simple capillary electrophoresis system was built with LED induced fluorescence detection and a credit card sized minicomputer to prove the concept of real time fluorescent imaging (zone adjustable time-lapse fluorescence image processor) and separation controller. The system was evaluated by analyzing under- and overloaded aminopyrenetrisulfonate (APTS)-labeled oligosaccharide samples. The open source software based image processing tool allowed undistorted signal modulation (reprocessing) if the signal was inappropriate for the actual detection system settings (too low or too high). The novel smart detection tool for fluorescently labeled biomolecules greatly expands dynamic range and enables retrospective correction for injections with unsuitable signal levels without the necessity to repeat the analysis.

  18. Folic acid functionalized silver nanoparticles with sensitivity and selectivity colorimetric and fluorescent detection for Hg2+ and efficient catalysis.

    Science.gov (United States)

    Su, Dongyue; Yang, Xin; Xia, Qingdong; Zhang, Qi; Chai, Fang; Wang, Chungang; Qu, Fengyu

    2014-09-05

    In this research, folic acid functionalized silver nanoparticles (FA-AgNPs) were selected as a colorimetric and a 'turn on' fluorescent sensor for detecting Hg(2+). After being added into Hg(2+), AgNPs can emit stable fluorescence at 440 nm when the excitation wavelength is selected at 275 nm. The absorbance and fluorescence of the FA-AgNPs could reflect the concentration of the Hg(2+) ions. Thus, we developed a simple, sensitive analytical method to detect Hg(2+) based on the colorimetric and fluorescence enhancement of FA-AgNPs. The sensor exhibits two linear response ranges between absorbance and fluorescence intensity with Hg(2+) concentration, respectively. Meanwhile, a detection limit of 1 nM is estimated based on the linear relationship between responses with a concentration of Hg(2+). The high specificity of Hg(2+) with FA-AgNPs interactions provided the excellent selectivity towards detecting Hg(2+) over other metal ions (Pb(2+), Mg(2+), Zn(2+), Ni(2+), Cu(2+), Co(2+), Ca(2+), Mn(2+), Fe(2+), Cd(2+), Ba(2+), Cr(6+) and Cr(3+)). This will provide a simple, effective and multifunctional colorimetric and fluorescent sensor for on-site and real-time Hg(2+) ion detection. The proposed method can be applied to the analysis of trace Hg(2+) in lake water. Additionally, the FA-AgNPs can be used as efficient catalyst for the reduction of 4-nitrophenol and potassium hexacyanoferrate (III).

  19. Label-free fluorescent detection of thrombin activity based on a recombinant enhanced green fluorescence protein and nickel ions immobilized nitrilotriacetic acid-coated magnetic nanoparticles.

    Science.gov (United States)

    Wang, Ming; Lei, Chunyang; Nie, Zhou; Guo, Manli; Huang, Yan; Yao, Shouzhuo

    2013-11-15

    Herein, a novel label-free fluorescent assay has been developed to detect the activity of thrombin and its inhibitor, based on a recombinant enhanced green fluorescence protein (EGFP) and Ni(2+) ions immobilized nitrilotriacetic acid-coated magnetic nanoparticles (Ni(2+)-NTA MNPs). The EGFP, containing a thrombin cleavage site and a hexahistidine sequence (His-tag) at its N-terminal, was adsorbed onto Ni(2+)-NTA MNPs through Ni(2+)-hexahistidine interaction, and dragged out of the solution by magnetic separation. Thrombin can selectively digest EGFP accompanied by His-tag peptide sequence leaving, and the resulting EGFP cannot be captured by Ni(2+)-NTA MNPs and kept in supernatant. Hence the fluorescence change of supernatant can clearly represent the activity of thrombin. Under optimized conditions, such assay showed a relatively low detection limit (3.0×10(-4) U mL(-1)), and was also used to detect the thrombin inhibitor, Hirudin, and further applied to detect thrombin activity in serum. Combined with the satisfactory reusability of Ni(2+)-NTA MNPs, our method presents a promising candidate for simple, sensitive, and cost-saving protease activity detecting and inhibitor screening. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Micro-Droplet Detection Method for Measuring the Concentration of Alkaline Phosphatase-Labeled Nanoparticles in Fluorescence Microscopy

    Directory of Open Access Journals (Sweden)

    Rufeng Li

    2017-11-01

    Full Text Available This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1 Gaussian filtering to remove the noise of overall fluorescent targets, (2 a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3 an red maximizing inter-class variance thresholding method (OTSU to segment the enhanced image for getting the binary map of the overall micro-droplets, (4 a circular Hough transform (CHT method to detect overall micro-droplets and (5 an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy.

  1. Micro-Droplet Detection Method for Measuring the Concentration of Alkaline Phosphatase-Labeled Nanoparticles in Fluorescence Microscopy.

    Science.gov (United States)

    Li, Rufeng; Wang, Yibei; Xu, Hong; Fei, Baowei; Qin, Binjie

    2017-11-21

    This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP) was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1) Gaussian filtering to remove the noise of overall fluorescent targets, (2) a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3) an red maximizing inter-class variance thresholding method (OTSU) to segment the enhanced image for getting the binary map of the overall micro-droplets, (4) a circular Hough transform (CHT) method to detect overall micro-droplets and (5) an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy.

  2. Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy

    KAUST Repository

    Ceylan Koydemir, Hatice

    2017-06-14

    Giardia lamblia is a waterborne parasite that affects millions of people every year worldwide, causing a diarrheal illness known as giardiasis. Timely detection of the presence of the cysts of this parasite in drinking water is important to prevent the spread of the disease, especially in resource-limited settings. Here we provide extended experimental testing and evaluation of the performance and repeatability of a field-portable and cost-effective microscopy platform for automated detection and counting of Giardia cysts in water samples, including tap water, non-potable water, and pond water. This compact platform is based on our previous work, and is composed of a smartphone-based fluorescence microscope, a disposable sample processing cassette, and a custom-developed smartphone application. Our mobile phone microscope has a large field of view of ~0.8 cm2 and weighs only ~180 g, excluding the phone. A custom-developed smartphone application provides a user-friendly graphical interface, guiding the users to capture a fluorescence image of the sample filter membrane and analyze it automatically at our servers using an image processing algorithm and training data, consisting of >30,000 images of cysts and >100,000 images of other fluorescent particles that are captured, including, e.g. dust. The total time that it takes from sample preparation to automated cyst counting is less than an hour for each 10 ml of water sample that is tested. We compared the sensitivity and the specificity of our platform using multiple supervised classification models, including support vector machines and nearest neighbors, and demonstrated that a bootstrap aggregating (i.e. bagging) approach using raw image file format provides the best performance for automated detection of Giardia cysts. We evaluated the performance of this machine learning enabled pathogen detection device with water samples taken from different sources (e.g. tap water, non-potable water, pond water) and achieved

  3. Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy

    Directory of Open Access Journals (Sweden)

    Ceylan Koydemir Hatice

    2017-06-01

    Full Text Available Giardia lamblia is a waterborne parasite that affects millions of people every year worldwide, causing a diarrheal illness known as giardiasis. Timely detection of the presence of the cysts of this parasite in drinking water is important to prevent the spread of the disease, especially in resource-limited settings. Here we provide extended experimental testing and evaluation of the performance and repeatability of a field-portable and cost-effective microscopy platform for automated detection and counting of Giardia cysts in water samples, including tap water, non-potable water, and pond water. This compact platform is based on our previous work, and is composed of a smartphone-based fluorescence microscope, a disposable sample processing cassette, and a custom-developed smartphone application. Our mobile phone microscope has a large field of view of ~0.8 cm2 and weighs only ~180 g, excluding the phone. A custom-developed smartphone application provides a user-friendly graphical interface, guiding the users to capture a fluorescence image of the sample filter membrane and analyze it automatically at our servers using an image processing algorithm and training data, consisting of >30,000 images of cysts and >100,000 images of other fluorescent particles that are captured, including, e.g. dust. The total time that it takes from sample preparation to automated cyst counting is less than an hour for each 10 ml of water sample that is tested. We compared the sensitivity and the specificity of our platform using multiple supervised classification models, including support vector machines and nearest neighbors, and demonstrated that a bootstrap aggregating (i.e. bagging approach using raw image file format provides the best performance for automated detection of Giardia cysts. We evaluated the performance of this machine learning enabled pathogen detection device with water samples taken from different sources (e.g. tap water, non-potable water, pond

  4. Comparison of supervised machine learning algorithms for waterborne pathogen detection using mobile phone fluorescence microscopy

    Science.gov (United States)

    Ceylan Koydemir, Hatice; Feng, Steve; Liang, Kyle; Nadkarni, Rohan; Benien, Parul; Ozcan, Aydogan

    2017-06-01

    Giardia lamblia is a waterborne parasite that affects millions of people every year worldwide, causing a diarrheal illness known as giardiasis. Timely detection of the presence of the cysts of this parasite in drinking water is important to prevent the spread of the disease, especially in resource-limited settings. Here we provide extended experimental testing and evaluation of the performance and repeatability of a field-portable and cost-effective microscopy platform for automated detection and counting of Giardia cysts in water samples, including tap water, non-potable water, and pond water. This compact platform is based on our previous work, and is composed of a smartphone-based fluorescence microscope, a disposable sample processing cassette, and a custom-developed smartphone application. Our mobile phone microscope has a large field of view of 0.8 cm2 and weighs only 180 g, excluding the phone. A custom-developed smartphone application provides a user-friendly graphical interface, guiding the users to capture a fluorescence image of the sample filter membrane and analyze it automatically at our servers using an image processing algorithm and training data, consisting of >30,000 images of cysts and >100,000 images of other fluorescent particles that are captured, including, e.g. dust. The total time that it takes from sample preparation to automated cyst counting is less than an hour for each 10 ml of water sample that is tested. We compared the sensitivity and the specificity of our platform using multiple supervised classification models, including support vector machines and nearest neighbors, and demonstrated that a bootstrap aggregating (i.e. bagging) approach using raw image file format provides the best performance for automated detection of Giardia cysts. We evaluated the performance of this machine learning enabled pathogen detection device with water samples taken from different sources (e.g. tap water, non-potable water, pond water) and achieved a

  5. Detection of trisomy 12 by fluorescent in situ hybridization (FISH in chronic lymphocytic leukemia

    Directory of Open Access Journals (Sweden)

    Maria de Lourdes L.F. Chauffaille

    2000-09-01

    Full Text Available Chronic lymphocytic leukemia (CLL presents a varying incidence of karyotypic abnormalities whose detection is complicated by difficulties in obtaining mitosis for analysis in this type of mature lymphocyte disorder. Since the introduction of molecular cytogenetics (FISH = fluorescent in situ hybridization, applying centromeric probes for chromosome 12 has made it possible to detect a higher percentage of trisomy 12 cases. The objective of the present study was to detect trisomy 12 by FISH (alpha satellite probe in 13 patients with CLL whose karyotypes by G-banding were either normal or inadequate. Using this method trisomy 12 was detected in three patients in a percentage of positive cells varying from 55.5% to 79%, showing that FISH is a sensitive and highly specific method for trisomy detection and should be routinely performed when the karyotype is normal.A leucemia linfocítica crônica (CLL apresenta incidência variável de anomalias de cariótipo devido às dificuldades em se obter mitose para análise. Desde a introdução da citogenética molecular (FISH = hibridação in situ por fluorescência usando sonda centromérica para o cromossomo 12 foi possível detectar uma maior porcentagem de casos com trissomia 12. O objetivo deste trabalho foi de detectar trissomia 12 por FISH (sonda alfa satélite em 13 pacientes com CLL cujos cariótipos por banda G haviam sido normais ou sem resultado. Três pacientes apresentaram trissomia 12 por este método com uma porcentagem de células trissômicas variando de 55,5 a 79%, demonstrando que a FISH é um método sensível e altamente específico para detecção de trissomia 12.

  6. New Monte Carlo model of cylindrical diffusing fibers illustrates axially heterogeneous fluorescence detection: simulation and experimental validation.

    Science.gov (United States)

    Baran, Timothy M; Foster, Thomas H

    2011-08-01

    We present a new Monte Carlo model of cylindrical diffusing fibers that is implemented with a graphics processing unit. Unlike previously published models that approximate the diffuser as a linear array of point sources, this model is based on the construction of these fibers. This allows for accurate determination of fluence distributions and modeling of fluorescence generation and collection. We demonstrate that our model generates fluence profiles similar to a linear array of point sources, but reveals axially heterogeneous fluorescence detection. With axially homogeneous excitation fluence, approximately 90% of detected fluorescence is collected by the proximal third of the diffuser for μ(s)'∕μ(a) = 8 in the tissue and 70 to 88% is collected in this region for μ(s)'∕μ(a) = 80. Increased fluorescence detection by the distal end of the diffuser relative to the center section is also demonstrated. Validation of these results was performed by creating phantoms consisting of layered fluorescent regions. Diffusers were inserted into these layered phantoms and fluorescence spectra were collected. Fits to these spectra show quantitative agreement between simulated fluorescence collection sensitivities and experimental results. These results will be applicable to the use of diffusers as detectors for dosimetry in interstitial photodynamic therapy.

  7. A Model System for Concurrent Detection of Antigen and Antibody Based on Immunological Fluorescent Method

    Directory of Open Access Journals (Sweden)

    Yuan-Cheng Cao

    2015-01-01

    Full Text Available This paper describes a combined antigen/antibody immunoassay implemented in a 96-well plate using fluorescent spectroscopic method. First, goat anti-human IgG was used to capture human IgG (model antigen; goat anti-human IgG (Cy3 or FITC was used to detect the model antigen; a saturating level of model antigen was then added followed by unlabelled goat anti-human IgG (model antibody; finally, Cy3 labelled rabbit anti-goat IgG was used to detect the model antibody. Two approaches were applied to the concomitant assay to analyze the feasibility. The first approach applied FITC and Cy3 when both targets were present at the same time, resulting in 50 ng/mL of the antibody detection limit and 10 ng/mL of antigen detection limit in the quantitative measurements of target concentration, taking the consideration of FRET efficiency of 68% between donor and acceptor. The sequential approach tended to lower the signal/noise (S/N ratio and the detection of the model antigen (lower than 1 ng/mL had better sensitivity than the model antibody (lower than 50 ng/mL. This combined antigen/antibody method might be useful for combined detection of antigens and antibodies. It will be helpful to screen for both antigen and antibody particularly in the situations of the multiserotype and high-frequency mutant virus infections.

  8. A highly selective chemosensor for colorimetric detection of Hg{sup 2+} and fluorescence detection of pH changes in aqueous solution

    Energy Technology Data Exchange (ETDEWEB)

    Kavitha, Ramasamy; Stalin, Thambusamy, E-mail: drstalin76@gmail.com

    2014-05-01

    A naturally existing and unmodified simple chemosensor, 2-hydroxy-1,4-naphthoquinone (2HNQ), was identified and used for both the colorimetric detection of Hg{sup 2+} and the fluorescent (on-off) detection of pH. The distinct color change and quenching of fluorescence emission was visible to the naked eye. More importantly, the chemosensor was used in combination with β-cyclodextrin (β-CD), which enabled the sensor to be solubilized and stabilized in aqueous solutions. The sensor selectively detected Hg{sup 2+} via the stable 1:1 complexation of the CåO and OH groups with Hg{sup 2+} and reflected pH changes in the range from 6 to 12 via a fluorescence on–off response resulting from the deprotonation of the hydroxyl group in 2HNQ. - Highlights: • The 2-Hydroxy-1,4-Naphthoquinone (2HNQ) chemosensor is capable of both colorimetric detection of Hg{sup 2+} and a fluorescence on-off response to pH. • The distinct color change and quenching of fluorescence emission are detectable with the naked eye. • The on– off fluorescence response in the pH range from 6– to 12 is due to the deprotonation of the hydroxyl group in 2HNQ.

  9. One-pot synthesis of gold nanoclusters with bright red fluorescence and good biorecognition abilities for visualization fluorescence enhancement detection of E. coli.

    Science.gov (United States)

    Liu, Jiali; Lu, Lili; Xu, Suying; Wang, Leyu

    2015-03-01

    A facile one-pot strategy was developed for the synthesis of lysozyme functionalized fluorescence gold nanoclusters (AuNCs). The lysozymes added to reduce Au(3+) ions and stabilize the AuNCs during the synthesis were coated on the AuNCs surface and retained their specific recognition ability for bacteria such as Escherichia coli (E. coli). Based on such ability, these AuNCs were specifically attached onto the surface of E. coli, which resulted in great red fluorescence enhancement. Nevertheless, the bovine serum albumin (BSA) stabilized AuNCs could not recognize E. coli and no fluorescence enhancement was observed. Upon the addition of E. coli, the red fluorescence intensity of lysozyme-AuNCs was enhanced linearly over the range of 2.4×10(4) -6.0×10(6) CFU/mL of E. coli with high sensitivity (LOD=2.0×10(4) CFU/mL, S/N=3). The visualization fluorescence evolution may enable the rapid and real-time detection of bacteria. This study may be extended to other functional proteins such as antibody, enzyme, and peptide functionalized nanoclusters while retaining the bioactivity of coating proteins and find wide applications in the fields of biochemistry and biomedicine. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Low light CMOS contact imager with an integrated poly-acrylic emission filter for fluorescence detection.

    Science.gov (United States)

    Dattner, Yonathan; Yadid-Pecht, Orly

    2010-01-01

    This study presents the fabrication of a low cost poly-acrylic acid (PAA) based emission filter integrated with a low light CMOS contact imager for fluorescence detection. The process involves the use of PAA as an adhesive for the emission filter. The poly-acrylic solution was chosen due its optical transparent properties, adhesive properties, miscibility with polar protic solvents and most importantly its bio-compatibility with a biological environment. The emission filter, also known as an absorption filter, involves dissolving an absorbing specimen in a polar protic solvent and mixing it with the PAA to uniformly bond the absorbing specimen and harden the filter. The PAA is optically transparent in solid form and therefore does not contribute to the absorbance of light in the visible spectrum. Many combinations of absorbing specimen and polar protic solvents can be derived, yielding different filter characteristics in different parts of the spectrum. We report a specific combination as a first example of implementation of our technology. The filter reported has excitation in the green spectrum and emission in the red spectrum, utilizing the increased quantum efficiency of the photo sensitive sensor array. The thickness of the filter (20 μm) was chosen by calculating the desired SNR using Beer-Lambert's law for liquids, Quantum Yield of the fluorophore and the Quantum Efficiency of the sensor array. The filters promising characteristics make it suitable for low light fluorescence detection. The filter was integrated with a fully functional low noise, low light CMOS contact imager and experimental results using fluorescence polystyrene micro-spheres are presented.

  11. [Establishment and Improvement of Portable X-Ray Fluorescence Spectrometer Detection Model Based on Wavelet Transform].

    Science.gov (United States)

    Li, Fang; Wang, Ji-hua; Lu, An-xiang; Han, Ping

    2015-04-01

    The concentration of Cr, Cu, Zn, As and Pb in soil was tested by portable X-ray fluorescence spectrometer. Each sample was tested for 3 times, then after using wavelet threshold noise filtering method for denoising and smoothing the spectra, a standard curve for each heavy metal was established according to the standard values of heavy metals in soil and the corresponding counts which was the average of the 3 processed spectra. The signal to noise ratio (SNR), mean square error (MSE) and information entropy (H) were taken to assess the effects of denoising when using wavelet threshold noise filtering method for determining the best wavelet basis and wavelet decomposition level. Some samples with different concentrations and H3 B03 (blank) were chosen to retest this instrument to verify its stability. The results show that: the best denoising result was obtained with the coif3 wavelet basis at the decomposition level of 3 when using the wavelet transform method. The determination coefficient (R2) range of the instrument is 0.990-0.996, indicating that a high degree of linearity was found between the contents of heavy metals in soil and each X-ray fluorescence spectral characteristic peak intensity with the instrument measurement within the range (0-1,500 mg · kg(-1)). After retesting and calculating, the results indicate that all the detection limits of the instrument are below the soil standards at national level. The accuracy of the model has been effectively improved, and the instrument also shows good precision with the practical application of wavelet transform to the establishment and improvement of X-ray fluorescence spectrometer detection model. Thus the instrument can be applied in on-site rapid screening of heavy metal in contaminated soil.

  12. Detection of Organic Matter in Greenland Ice Cores by Deep-UV Fluorescence

    Science.gov (United States)

    Willis, M.; Malaska, M.; Wanger, G.; Bhartia, R.; Eshelman, E.; Abbey, W.; Priscu, J. C.

    2017-12-01

    The Greenland Ice Sheet is an Earthly analog for icy ocean worlds in the outer Solar System. Future missions to such worlds including Europa, Enceladus, and Titan may potentially include spectroscopic instrumentation to examine the surface/subsurface. The primary goal of our research is to test deep UV/Raman systems for in the situ detection and localization of organics in ice. As part of this effort we used a deep-UV fluorescence instrument able to detect naturally fluorescent biological materials such as aromatic molecules found in proteins and whole cells. We correlated these data with more traditional downstream analyses of organic material in natural ices. Supraglacial ice cores (2-4 m) were collected from several sites on the southwest outlet of the Greenland Ice Sheet using a 14-cm fluid-free mechanical coring system. Repeat spectral mapping data were initially collected longitudinally on uncut core sections. Cores were then cut into 2 cm thick sections along the longitudinal axis, slowly melted and analyzed for total organic carbon (TOC), total dissolved nitrogen (TDN), and bacterial density. These data reveal a spatial correlation between organic matter concentration, cell density, and the deep UV fluorescence maps. Our results provide a profile of the organics embedded within the ice from the top surface into the glacial subsurface, and the TOC:TDN data from the clean interior of the cores are indicative of a biological origin. This work provides a background dataset for future work to characterize organic carbon in the Greenland Ice Sheet and validation of novel instrumentation for in situ data collection on icy bodies.

  13. Selective detection of Mg2+ ions via enhanced fluorescence emission using Au–DNA nanocomposites

    Directory of Open Access Journals (Sweden)

    Tanushree Basu

    2017-04-01

    Full Text Available The biophysical properties of DNA-modified Au nanoparticles (AuNPs have attracted a great deal of research interest for various applications in biosensing. AuNPs have strong binding capability to the phosphate and sugar groups in DNA, rendering unique physicochemical properties for detection of metal ions. The formation of Au–DNA nanocomposites is evident from the observed changes in the optical absorption, plasmon band, zeta potential, DLS particle size distribution, as well as TEM and AFM surface morphology analysis. Circular dichroism studies also revealed that DNA-functionalized AuNP binding caused a conformational change in the DNA structure. Due to the size and shape dependent plasmonic interactions of AuNPs (33–78 nm with DNA, the resultant Au–DNA nanocomposites (NCs exhibit superior fluorescence emission due to chemical binding with Ca2+, Fe2+ and Mg2+ ions. A significant increase in fluorescence emission (λex = 260 nm of Au–DNA NCs was observed after selectively binding with Mg2+ ions (20–800 ppm in an aqueous solution where a minimum of 100 ppm Mg2+ ions was detected based on the linearity of concentration versus fluorescence intensity curve (λem = 400 nm. The effectiveness of Au–DNA nanocomposites was further verified by comparing the known concentration (50–120 ppm of Mg2+ ions in synthetic tap water and a real life sample of Gelusil (300–360 ppm Mg2+, a widely used antacid medicine. Therefore, this method could be a sensitive tool for the estimation of water hardness after careful preparation of a suitably designed Au–DNA nanostructure.

  14. Quantification of Small Extracellular Vesicles by Size Exclusion Chromatography with Fluorescence Detection.

    Science.gov (United States)

    Xu, Rui; Fitts, Austin; Li, Xiangtang; Fernandes, Joseph; Pochampally, Radhika; Mao, Jinghe; Liu, Yi-Ming

    2016-11-01

    Chemical analysis of small extracellular vesicles (sEVs) circulating in body fluids holds potentials in noninvasive diagnosis of diseases and evaluation of therapeutic treatments. However, quantification of sEVs remains a challenge due to lacking of cost-effective analytical protocols. Herein we report a facile method based on size exclusion chromatography with fluorescence detection (SEC-FD) for sEVs quantification. After removal of cells and cell debris, a 0.50 mL sample (e.g., cell culture medium) is incubated with CM-Dil dye to fluorescently label sEVs. The incubation solution is then separated on a SEC column packed with Sepharose CL-4B. The eluent is monitored fluorescently at Ex553 nm/Em570 nm by using a fluorometer equipped with a 50-μL flow through cuvette. Separation efficiency of the proposed SEC-FD method was evaluated by analyzing 100 nm liposomes and albumin-FITC conjugate. Liposomes were eluted out in less than 6 min, about 10 min before albumin-FITC. A separation repeatability (RSD in retention time) of 1.4% (n = 5) was obtained for liposomes. In analysis of cell culture media, linear calibration curves based on SEC-FD peak height versus sEVs concentration were obtained with r 2 value of 0.996. Intraday quantification repeatability (RSD in peak height) was 3.2% (n = 5). The detection limit was estimated to be 2.9 × 10 7 exosome particles/mL. The proposed assay was applied to the first study of sEVs secretion from TK6 cells cultured in serum-free medium for a culturing period from 1 to 48 h.

  15. Automated Aflatoxin Analysis Using Inline Reusable Immunoaffinity Column Cleanup and LC-Fluorescence Detection.

    Science.gov (United States)

    Rhemrev, Ria; Pazdanska, Monika; Marley, Elaine; Biselli, Scarlett; Staiger, Simone

    2015-01-01

    A novel reusable immunoaffinity cartridge containing monoclonal antibodies to aflatoxins coupled to a pressure resistant polymer has been developed. The cartridge is used in conjunction with a handling system inline to LC with fluorescence detection to provide fully automated aflatoxin analysis for routine monitoring of a variety of food matrixes. The handling system selects an immunoaffinity cartridge from a tray and automatically applies the sample extract. The cartridge is washed, then aflatoxins B1, B2, G1, and G2 are eluted and transferred inline to the LC system for quantitative analysis using fluorescence detection with postcolumn derivatization using a KOBRA® cell. Each immunoaffinity cartridge can be used up to 15 times without loss in performance, offering increased sample throughput and reduced costs compared to conventional manual sample preparation and cleanup. The system was validated in two independent laboratories using samples of peanuts and maize spiked at 2, 8, and 40 μg/kg total aflatoxins, and paprika, nutmeg, and dried figs spiked at 5, 20, and 100 μg/kg total aflatoxins. Recoveries exceeded 80% for both aflatoxin B1 and total aflatoxins. The between-day repeatability ranged from 2.1 to 9.6% for aflatoxin B1 for the six levels and five matrixes. Satisfactory Z-scores were obtained with this automated system when used for participation in proficiency testing (FAPAS®) for samples of chilli powder and hazelnut paste containing aflatoxins.

  16. Medically Relevant Assays with a Simple Smartphone and Tablet Based Fluorescence Detection System

    Directory of Open Access Journals (Sweden)

    Piotr Wargocki

    2015-05-01

    Full Text Available Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  17. Rapid Detection of Glycogen Synthase Kinase-3 Activity in Mouse Sperm Using Fluorescent Gel Shift Electrophoresis

    Directory of Open Access Journals (Sweden)

    Hoseok Choi

    2016-04-01

    Full Text Available Assaying the glycogen synthase kinase-3 (GSK3 activity in sperm is of great importance because it is closely implicated in sperm motility and male infertility. While a number of studies on GSK3 activity have relied on labor-intensive immunoblotting to identify phosphorylated GSK3, here we report the simple and rapid detection of GSK3 activity in mouse sperm using conventional agarose gel electrophoresis and a fluorescent peptide substrate. When a dye-tethered and prephosphorylated (primed peptide substrate for GSK3 was employed, a distinct mobility shift in the fluorescent bands on the agarose was observed by GSK3-induced phosphorylation of the primed peptides. The GSK3 activity in mouse testes and sperm were quantifiable by gel shift assay with low sample consumption and were significantly correlated with the expression levels of GSK3 and p-GSK3. We suggest that our assay can be used for reliable and rapid detection of GSK3 activity in cells and tissue extracts.

  18. Sensitive detection of copper ions via ion-responsive fluorescence quenching of engineered porous silicon nanoparticles

    Science.gov (United States)

    Hwang, Jangsun; Hwang, Mintai P.; Choi, Moonhyun; Seo, Youngmin; Jo, Yeonho; Son, Jaewoo; Hong, Jinkee; Choi, Jonghoon

    2016-10-01

    Heavy metal pollution has been a problem since the advent of modern transportation, which despite efforts to curb emissions, continues to play a critical role in environmental pollution. Copper ions (Cu2+), in particular, are one of the more prevalent metals that have widespread detrimental ramifications. From this perspective, a simple and inexpensive method of detecting Cu2+ at the micromolar level would be highly desirable. In this study, we use porous silicon nanoparticles (NPs), obtained via anodic etching of Si wafers, as a basis for undecylenic acid (UDA)- or acrylic acid (AA)-mediated hydrosilylation. The resulting alkyl-terminated porous silicon nanoparticles (APS NPs) have enhanced fluorescence stability and intensity, and importantly, exhibit [Cu2+]-dependent quenching of fluorescence. After determining various aqueous sensing conditions for Cu2+, we demonstrate the use of APS NPs in two separate applications - a standard well-based paper kit and a portable layer-by-layer stick kit. Collectively, we demonstrate the potential of APS NPs in sensors for the effective detection of Cu2+.

  19. Differential Leukocyte Counting via Fluorescent Detection and Image Processing on a Centrifugal Microfluidic Platform.

    Science.gov (United States)

    Balter, Max L; Chen, Alvin I; Colinco, C Amara; Gorshkov, Alexander; Bixon, Brian; Martin, Vincent; Fromholtz, Alexander; Maguire, Timothy J; Yarmush, Martin L

    2016-12-21

    Centrifugal microfluidics has received much attention in the last decade for the automation of blood testing at the point-of-care, specifically for the detection of chemistries, proteins, and nucleic acids. However, the detection of common blood cells on-disc, particularly leukocytes, remains a challenge. In this paper, we present two analytical methods for enumerating leukocytes on a centrifugal platform using a custom-built fluorescent microscope, acridine orange nuclear staining, and image processing techniques. In the first method, cell analysis is performed in glass capillary tubes; in the second, acrylic chips are used. A bulk-cell analysis approach is implemented in both cases where the pixel areas of fractionated lymphocyte/monocyte and granulocyte layers are correlated with cell counts. Generating standard curves using porcine blood sample controls, we observed strong linear fits to measured cell counts using both methods. Analyzing the pixel intensities of the fluorescing white cell region, we are able to differentiate lymphocytes from monocytes via pixel clustering, demonstrating the capacity to perform a 3-part differential. Finally, a discussion of pros and cons of the bulk-cell analysis approach concludes the paper.

  20. Stepwise multiphoton activation fluorescence reveals a new method of melanin detection

    Science.gov (United States)

    Lai, Zhenhua; Kerimo, Josef; Mega, Yair; DiMarzio, Charles A.

    2013-06-01

    The stepwise multiphoton activated fluorescence (SMPAF) of melanin, activated by a continuous-wave mode near infrared (NIR) laser, reveals a broad spectrum extending from the visible spectra to the NIR and has potential application for a low-cost, reliable method of detecting melanin. SMPAF images of melanin in mouse hair and skin are compared with conventional multiphoton fluorescence microscopy and confocal reflectance microscopy (CRM). By combining CRM with SMPAF, we can locate melanin reliably. However, we have the added benefit of eliminating background interference from other components inside mouse hair and skin. The melanin SMPAF signal from the mouse hair is a mixture of a two-photon process and a third-order process. The melanin SMPAF emission spectrum is activated by a 1505.9-nm laser light, and the resulting spectrum has a peak at 960 nm. The discovery of the emission peak may lead to a more energy-efficient method of background-free melanin detection with less photo-bleaching.

  1. Fabrication of high performance microlenses for an integrated capillary channel electrochromatograph with fluorescence detection

    International Nuclear Information System (INIS)

    Wendt, J. R.; Warren, M. E.; Sweatt, W. C.; Bailey, C. G.; Matzke, C. M.; Arnold, D. W.; Allerman, A. A.; Carter, T. R.; Asbill, R. E.; Samora, S.

    1999-01-01

    We describe the microfabrication of an extremely compact optical system as a key element in an integrated capillary channel electrochromatograph with fluorescence detection. The optical system consists of a vertical cavity surface-emitting laser (VCSEL), two high performance microlenses, and a commercial photodetector. The microlenses are multilevel diffractive optics patterned by electron beam lithography and etched by reactive ion etching in fused silica. The design uses substrate-mode propagation within the fused silica substrate. Two generations of optical subsystems are described. The first generation design has a 6 mm optical length and is integrated directly onto the capillary channel-containing substrate. The second generation design separates the optical system onto its own substrate module and the optical path length is further compressed to 3.5 mm. The first generation design has been tested using direct fluorescence detection with a 750 nm VCSEL pumping a 10 -4 M solution of CY-7 dye. The observed signal-to-noise ratio of better than 100:1 demonstrates that the background signal from scattered pump light is low despite the compact size of the optical system and is adequate for system sensitivity requirements. (c) 1999 American Vacuum Society

  2. A sensitive fluorescence method for detection of E. Coli using rhodamine 6G dyeing.

    Science.gov (United States)

    Wang, Yaohui; Jiang, Caina; Wen, Guiqing; Zhang, Xinghui; Luo, Yanghe; Qin, Aimiao; Liang, Aihui; Jiang, Zhiliang

    2016-06-01

    Negatively charged bacteria combined with positively charged alkaline dye rhodamine 6G (Rh6G) in NaH2 PO4 -Na2 HPO4 buffer solution pH 7.4, by electrostatic interaction. The dyed bacteria exhibited a strong fluorescence peak at 552 nm and fluorescence intensity was directly linear to Escherichia coli (E. coli), Bacillus subtilis (B. subtilis) and Staphylococcus aureus (S. aureus) concentrations in the range of 7.06 × 10(4) to 3.53 × 10(7) , 4.95 × 10(5) to 2.475 × 10(8) and 32.5 to 16250 colony forming unit/mL (cfu/mL) respectively, with detection limits of 3.2 × 10(4) cfu/mL E. coli, 2.3 × 10(5) cfu/mL B. subtilis and 16 cfu/mL S. aureus, respectively. Samples were cultured for 12 h, after which the linear detection range for E. coli was 2 to 88 cfu/mL. This simple, rapid and sensitive method was used for the analysis of water and drinking samples. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Fluorescence in situ hybridization detection of cytogenetic abnormalities and prognosis in multiple myeloma

    Directory of Open Access Journals (Sweden)

    Zhou Xu

    2015-01-01

    Full Text Available We evaluated the prognosis of patients with newly diagnosed multiple myeloma (MM and attempted to find a suitable treatment strategy for them. Interphase fluorescence in situ hybridization (FISH detection was performed on 57 patients with MM. The following probes: IgH, p53, 1q21, RB1, and D13S319 specific for the rearrangements of 14q32, 17p13, 1q21 and 13q14 were used. Fluorescent hybridization signals were observed using an Olympus BX60 epifluorescence microscope equipped with filters for detecting fluoroisothiocyanate (FITC, Texas red, and 4'-6-Diamidino-2-phenylindole (DAPI. Triple color clone-specific images were captured using a Quips XL genetic workstation. The mortalities in patients with moderate prognosis (66.7% and poor prognosis (50% were significantly higher compared with that in patients with good prognosis (15%, P<0.05. All the patients in good and moderate prognosis groups achieved complete remission (CR/very good partial remission (VGPR/partial remission (PR, whereas only half of the cases in the poor prognosis group reached this level. Patients 2 supported by autologous hematopoietic stem-cell transplantation presented CR/PR and long survival. For those with poor prognosis, a proper therapeutic regimen and timely transplantation, especially tandem transplantation, was necessary due to the rapid progression and complications.

  4. Liquid chromatographic determination of zearalenone and zearalenol in animal feeds and grains, using fluorescence detection.

    Science.gov (United States)

    Bagneris, R W; Gaul, J A; Ware, G M

    1986-01-01

    A liquid chromatographic (LC) method was developed for the determination of zearalenone and zearalenol in grains and mixed animal feeds. Samples are extracted with chloroform and purified by a base-acid liquid-liquid partition. Zearalenone and zearalenol are separated by reverse phase LC and determined by fluorescence detection, excitation wavelength 236 nm with a 418 nm cutoff filter. The method was applied to the determination of zearalenone and zearalenol in 395 survey samples of corn, oats, barley, sorghum, silage, and finished feeds. The limit of detection is 10 ng/g for both toxins. The range of naturally occurring toxins found was 10-4,000 ng/g. Average recoveries were 84% for zearlenone and 69% for zearalenol. Coefficients of variation were 24.6% for zearalenone and 30.8% for zearalenol for crop year 1980, and 28.3% for zearalenone and 22.0% for zearalenol for crop year 1981.

  5. A highly flexible polymerization technique to prepare fluorescent nanospheres for trace ammonia detection

    International Nuclear Information System (INIS)

    Waich, K.; Sandholzer, M.; Mayr, T.; Slugovc, C.; Klimant, I.

    2010-01-01

    The preparation of pH-sensitive nanospheres by emulsion polymerization for the detection of trace levels of ammonia is described. A fluorescent, polymerizable xanthene dye was copolymerized with styrene, crosslinkers and further copolymers aimed at enhancing the sensitivity to obtain materials for sensing of ammonia. A half-seeded technique was used to obtain stable emulsions of the monomers which were cured to obtain nanospheres with covalently attached active components. The nanospheres were embedded in a silicon matrix and the sensor films obtained were investigated regarding their response to ammonia at concentrations between 25 and 1,000 ppb. Sensors containing polystyrene nanospheres crosslinked with divinylbenzene showed the best performance in ammonia measurements exhibiting detection limits (LODs) of less than 25 ppb ammonia.

  6. Fluorescence hyper-spectral imaging to detecting faecal contamination on fresh tomatoes

    Directory of Open Access Journals (Sweden)

    Roberto Romaniello

    2016-03-01

    Full Text Available Faecal contamination of fresh fruits represents a severe danger for human health. Thus some techniques based on microbiological testing were developed to individuate faecal contaminants but those tests do not results efficient because their non-applicability on overall vegetable unity. In this work a methodology based on hyper-spectral fluorescence imaging was developed and tested to detecting faecal contamination on fresh tomatoes. Two image-processing methods were performed to maximise the contrast between the faecal contaminant and tomatoes skin: principal component analysis and band image ratio (BRI. The BRI method allows classifying correctly 70% of contaminated area, with no false-positives in all examined cases. Thus, the developed methodology can be employed for a fast and effective detection of faecal contamination on fresh tomatoes.

  7. An airborne lidar instrument for detection of OH using the technique of laser-induced fluorescence

    Science.gov (United States)

    Davis, L. I., Jr.; James, J. V.; Morris, P. T.; Guo, C.; Postiff, R.

    1985-01-01

    Under suitable laboratory conditions, it has been demonstrated that the laser-induced fluorescence (LIF) measurement technique is sensitive enough to detect single atoms and molecules. This potential sensitivity has provided motivation for the development of this technique for ambient OH measurements. The present paper is concerned with an airborne lidar instrument for measuring OH concentration as used for the NASA GTE/CITE (Global Tropospheric Experiment/Chemical Instrumentation Test and Evaluation) intercomparison experiments during the fall of 1983 and the spring of 1984. A description is given of a working airborne instrument for measurements of OH in ambient air. The detection sensitivity demonstrated in the experiments should be sufficient for routine measurements in areas in which the OH concentration is in the range of high 1,000,000 molecule per cu cm or higher.

  8. A novel fluorescent probe (dtpa-bis(cytosine)) for detection of Eu(III) in rare earth metal ions

    Science.gov (United States)

    Yang, Fan; Ren, Peipei; Liu, Guanhong; Song, Youtao; Bu, Naishun; Wang, Jun

    2018-03-01

    In this paper, a novel fluorescent probe, dtpa-bis(cytosine), was designed and synthesized for detecting europium (Eu3 +) ion. Upon addition of Eu3 + ions into the dtpa-bis(cytosine) solution, the fluorescence intensity can strongly be enhanced. Conversely, adding other rare earth metal ions, such as Y3 +, Ce3 +, Pr3 +, Nd3 +, Sm3 +, Gd3 +, Tb3 +, Dy3 +, Ho3 +, Er3 +, Yb3 + and Lu3 +, into dtpa-bis(cytosine) solution, the fluorescence intensity is decreased slightly. Some parameters affecting the fluorescence intensity of dtpa-bis(cytosine) solution in the presence of Eu3 + ions were investigated, including solution pH value, Eu3 + ion concentration and interfering substances. The detection mechanism of Eu3 + ion using dtpa-bis(cytosine) as fluorescent probe was proposed. Under optimum conditions, the fluorescence emission intensities of EuIII-dtpa-bis(cytosine) at 375 nm in the concentration range of 0.50 × 10- 5 mol • L- 1-5.00 × 10- 5 mol • L- 1 of Eu3 + ion display a better linear relationship. The limit of detection (LOD) was determined as 8.65 × 10- 7 mol • L- 1 and the corresponding correlation coefficient (R2) of the linear equation is 0.9807. It is wished that the proposed method could be applied for sensitively and selectively detecting Eu3 + ion.

  9. Gateway Vectors for Simultaneous Detection of Multiple Protein-Protein Interactions in Plant Cells Using Bimolecular Fluorescence Complementation.

    Science.gov (United States)

    Kamigaki, Akane; Nito, Kazumasa; Hikino, Kazumi; Goto-Yamada, Shino; Nishimura, Mikio; Nakagawa, Tsuyoshi; Mano, Shoji

    2016-01-01

    Bimolecular fluorescence complementation (BiFC) is widely used to detect protein-protein interactions, because it is technically simple, convenient, and can be adapted for use with conventional fluorescence microscopy. We previously constructed enhanced yellow fluorescent protein (EYFP)-based Gateway cloning technology-compatible vectors. In the current study, we generated new Gateway cloning technology-compatible vectors to detect BiFC-based multiple protein-protein interactions using N- and C-terminal fragments of enhanced cyan fluorescent protein (ECFP), enhanced green fluorescent protein (EGFP), and monomeric red fluorescent protein (mRFP1). Using a combination of N- and C-terminal fragments from ECFP, EGFP and EYFP, we observed a shift in the emission wavelength, enabling the simultaneous detection of multiple protein-protein interactions. Moreover, we developed these vectors as binary vectors for use in Agrobacterium infiltration and for the generate transgenic plants. We verified that the binary vectors functioned well in tobacco cells. The results demonstrate that the BiFC vectors facilitate the design of various constructions and are convenient for the detection of multiple protein-protein interactions simultaneously in plant cells.

  10. Gateway Vectors for Simultaneous Detection of Multiple Protein−Protein Interactions in Plant Cells Using Bimolecular Fluorescence Complementation

    Science.gov (United States)

    Hikino, Kazumi; Goto-Yamada, Shino; Nishimura, Mikio; Nakagawa, Tsuyoshi; Mano, Shoji

    2016-01-01

    Bimolecular fluorescence complementation (BiFC) is widely used to detect protein—protein interactions, because it is technically simple, convenient, and can be adapted for use with conventional fluorescence microscopy. We previously constructed enhanced yellow fluorescent protein (EYFP)-based Gateway cloning technology-compatible vectors. In the current study, we generated new Gateway cloning technology-compatible vectors to detect BiFC-based multiple protein—protein interactions using N- and C-terminal fragments of enhanced cyan fluorescent protein (ECFP), enhanced green fluorescent protein (EGFP), and monomeric red fluorescent protein (mRFP1). Using a combination of N- and C-terminal fragments from ECFP, EGFP and EYFP, we observed a shift in the emission wavelength, enabling the simultaneous detection of multiple protein—protein interactions. Moreover, we developed these vectors as binary vectors for use in Agrobacterium infiltration and for the generate transgenic plants. We verified that the binary vectors functioned well in tobacco cells. The results demonstrate that the BiFC vectors facilitate the design of various constructions and are convenient for the detection of multiple protein—protein interactions simultaneously in plant cells. PMID:27490375

  11. Rhodol-based far-red fluorescent probe for the detection of cysteine and homocysteine over glutathione.

    Science.gov (United States)

    Liu, Yunchang; Xiang, Kaiqiang; Tian, Baozhu; Zhang, Jinlong

    2017-02-01

    The simultaneous discrimination of cysteine (Cys), homocysteine (Hcy) and glutathione (GSH) is of great importance due to their roles in biology and close link to many diseases, especially via the development of a far-red fluorescent probe that could be used for rapid, selective, and sensitive detection of all three. Herein, we report the characterization of a far-red fluorescent probe with turn-on fluorescence properties and visible color changes that could be used for the detection of cysteine and homocysteine over glutathione. In this study we found that the sensor could discriminate cysteine and homocysteine over glutathione within 20 min. Function of this probe was based on the conjugate addition-cyclization reaction and showed a low detection limit to cysteine and homocysteine. Upon the addition of cysteine and homocysteine, the absorption band at 592 nm rose gradually and fluorescence was detected at 645 nm. The color changed from colorless to blue and fluorescence changed from absent to strong red fluorescence, which could be differentiated by the naked eye. All these unique features make this probe particularly potentially favorable for use in cysteine/homocysteine sensing and bioimaging applications. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  12. A fluorescence method for detection of DNA and DNA methylation based on graphene oxide and restriction endonuclease HpaII.

    Science.gov (United States)

    Wei, Wei; Gao, Chunyan; Xiong, Yanxiang; Zhang, Yuanjian; Liu, Songqin; Pu, Yuepu

    2015-01-01

    DNA methylation plays an important role in many biological events and is associated with various diseases. Most traditional methods for detection of DNA methylation are based on the complex and expensive bisulfite method. In this paper, we report a novel fluorescence method to detect DNA and DNA methylation based on graphene oxide (GO) and restriction endonuclease HpaII. The skillfully designed probe DNA labeled with 5-carboxyfluorescein (FAM) and optimized GO concentration keep the probe/target DNA still adsorbed on the GO. After the cleavage action of HpaII the labeled FAM is released from the GO surface and its fluorescence recovers, which could be used to detect DNA in the linear range of 50 pM-50 nM with a detection limit of 43 pM. DNA methylation induced by transmethylase (Mtase) or other chemical reagents prevents HpaII from recognizing and cleaving the specific site; as a result, fluorescence cannot recover. The fluorescence recovery efficiency is closely related to the DNA methylation level, which can be used to detect DNA methylation by comparing it with the fluorescence in the presence of intact target DNA. The method for detection of DNA and DNA methylation is simple, reliable and accurate. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Remote detection of buried explosives by fluorescent and bioluminescent microbial sensors (Conference Presentation)

    Science.gov (United States)

    Belkin, Shimshon; Yagur-Kroll, Sharon; Zohar, Cheinat; Rabinovitz, Zahi; Nussinovitch, Amos; Kabessa, Yossi; Agranat, Aharon J.

    2017-06-01

    Current landmine detection methodologies are not much different in principle from those employed 75 years ago, in that they require actual presence in the minefield, with obvious risks to personnel and equipment. Other limitations include an extremely large ratio of false positives, as well as a very limited ability to detect non-metallic landmines. In this lecture a microbial-based solution for the remote detection of buried landmines described. The small size requirements, rapid responses and sensing versatility of bacterial bioreporters allow their integration into diverse types of devices, for laboratory as well as field applications. The relative ease by which molecular sensing and reporting elements can be fused together to generate dose-dependent quantifiable physical (luminescent, fluorescent, colorimetric, electrochemical) responses to pre-determined conditions allows the construction of diverse classes of sensors. Over the last two decades we and others have employed this principle to design and construct microbial bioreporter strains for the sensitive detection of (a) specific chemicals of environmental concern (heavy metals, halogenated organics etc.) or (b) their deleterious biological effects on living systems (such as toxicity or genotoxicity). In many of these cases, additional molecular manipulations beyond the initial sensor-reporter fusion may be highly beneficial for enhancing the performance of the engineered sensor systems. This presentation highlights several of the approaches we have adopted over the years to achieve this aim, while focusing on the application of live cell microbeads for the remote detection of buried landmines and other explosive devices.

  14. Micro-RNA detection based on fluorescence resonance energy transfer of DNA-carbon quantum dots probes.

    Science.gov (United States)

    Khakbaz, Faeze; Mahani, Mohamad

    2017-04-15

    Carbon quantum dots have been proposed as an effective platform for miRNA detection. Carbon dots were synthesized by citric acid. The synthesized dots were characterized by dynamic light scattering, UV-Vis spectrophotometry, spectrofluorimetry, transmission electron microscopy and FT-IR spectrophotometry. The fluorescence quantum yield of the synthesized dots was determined using quinine sulfate as the standard. The FAM-labeled single stranded DNA, as sensing element, was adsorbed on dots by π-π interaction. The quenching of the dots fluorescence due to fluorescence resonance energy transfer (FRET) was used for mir 9-1 detection. In the presence of the complementary miRNA, the FRET did not take place and the fluorescence was recovered. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Hydrodynamic size characterization of a self-emulsifying lipid pharmaceutical excipient by Taylor dispersion analysis with fluorescent detection.

    Science.gov (United States)

    Chamieh, Joseph; Jannin, Vincent; Demarne, Frédéric; Cottet, Hervé

    2016-11-20

    In this work, the sizing of microemulsion droplets of a lipid-based pharmaceutical excipient (Labrasol ® ALF) is performed by Taylor dispersion analysis (TDA) using fluorescent detection. An hydrophobic fluorescent marker is used to tag the microemulsion droplet and to increase the sensitivity of detection (compared to UV detection). Combined with the frontal TDA mode, fluorescent detection was mandatory for an accurate sizing of microemulsions containing large coacervates. Microemulsion sizing of Labrasol was performed at various concentrations from 1 to 70g.L -1 and at two different temperature (25°C and 37°C). Results obtained by TDA are compared to those derived from DLS measurements. The combination of both techniques allows estimating the size and proportion of coacervates in the microemulsion, as well as the polydispersity in size of the sample. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Dimethylaminodiethylenetriamine Derivatives of Fluorescence Chemosenso for Detection of Zn2+ In Aqueous Solution

    Science.gov (United States)

    Adnan, S. N. A. M.; Hasan, S.; Zakaria, S.; Yusof, Y. M.

    2017-02-01

    Fluorescent chemosensors for the detection and measurement of metal ions, especially for cations environmental interest such as Fe3+, Co2+, Mn2+, Cu2+, and Zn2+ are actively investigated because it shows simplicity, high sensitivity and fast response. New benzenyl derivative bearing pyridine group has been synthesized and studied as fluorescent chemosensor for Zn2+ ion. Chemosensor N-{2-[(4-Dimethylamino-benzylidene)-amino]-ethyl}-N’-pyridin-2-ylmethylene-ethane-1,2-diamine was synthesized by condensation of p-dimethylaminobenzaldehyde, diethylenetriamine and o-pyridinecarbaldehyde and characterized by FT-IR, 1H-NMR and elemental analysis (CHN). FT-IR showed the appearance of peak azomethine (C=NH) at 1639.46 cm-1, pyridine (C-N) at 1591 cm-1and disappearance of NH2 peak at 3278.78 cm-1 after the condensation reaction in between aldehyde and amine. 1H-NMR signal at 8.19 ppm, 3.12 ppm and 8.08 ppm was assigned to C=NH, N(CH3)2 and C-N respectively, confirmed the formation of N-{2-[(4-Dimethylamino-benzylidene)-amino]-ethyl}-N’-pyridin-2-ylmethylene-ethane-1,2-diamine. The elemental analysis was found closed to the theoretical value and the percent composition of A is 91.82%. Sensor A exhibits high selectivity and sensitivity towards Zn2+. Other metal ions such Cu2+, Fe3+, Co2+ and Ni2+ had no such significant effect on the fluorescence. The detection limit of N-{2-[(4-Dimethylamino-benzylidene)-amino]-ethyl}-N’-pyridin-2-ylmethylene-ethane-1,2-diamine for Zn2+ was 3.5 x 10-5 M. M. This sensor exhibits a very good fluorescence sensing ability to Zn2+ over a wide range of pH. Therefore it is capable of being a practical system for the monitoring of Zn2+ concentrations in real water sample.

  17. Use of Green Fluorescent Protein To Detect Expression of an Endopolygalacturonase Gene of Colletotrichum lindemuthianum during Bean Infection

    OpenAIRE

    Dumas, Bernard; Centis, Sylvie; Sarrazin, Nathalie; Esquerré-Tugayé, Marie-Thérèse

    1999-01-01

    The 5′ noncoding region of clpg2, an endopolygalacturonase gene of the bean pathogen Colletotrichum lindemuthianum, was fused to the coding sequence of a gene encoding a green fluorescent protein (GFP), and the construct was introduced into the fungal genome. Detection of GFP accumulation by fluorescence microscopy examination revealed that clpg2 was expressed at the early stages of germination of the conidia and during appressorium formation both in vitro and on the host plant.

  18. Determination of inorganic arsenic and its organic metabolites in urine by flow-injection hydride generation atomic absorption spectrometry.

    Science.gov (United States)

    Hanna, C P; Tyson, J F; McIntosh, S

    1993-08-01

    A method has been developed for the determination of inorganic arsenic [As(III) and As(V)] and its organic metabolites (monomethylarsenic and dimethylarsenic) in urine by flow-injection hydride generation atomic absorption spectrometry. The nontoxic seafood-derived arsenobetaine and arsenocholine species were first separated by a solid-phase extraction procedure. The remaining sample was digested with a mixture of nitric and sulfuric acids and potassium dichromate, followed by attack with hydrogen peroxide. The resulting As(V) was reduced to As(III) with potassium iodide in hydrochloric acid before injection into the flow-injection manifold. The percentage analytical recoveries (mean +/- 95% confidence interval) of various arsenic species added to a urine specimen at 250 micrograms/L were 108 +/- 2, 112 +/- 11, 104 +/- 7, and 95 +/- 5 for As(III), As(V), monomethylarsenic, and dimethylarsenic, respectively. For the determination of arsenic in Standard Reference Material 2670 (toxic metals in human urine), results agreed with the certified value (480 +/- 100 micrograms/L). Analyses of samples for the Centre de Toxicologie du Quebec, containing seafood-derived species, demonstrated the viability of the separation procedure. Detection limits were between 0.1 and 0.2 microgram/L in the solution injected into the manifold, and precision at 10 micrograms/L was between 2% and 3% (CV). These preliminary results show that the method might be applicable to determinations of arsenic in a range of clinical urine specimens.

  19. A modified routine analysis of arsenic content in drinking-water in Bangladesh by hydride generation-atomic absorption spectrophotometry.

    Science.gov (United States)

    Wahed, M A; Chowdhury, Dulaly; Nermell, Barbro; Khan, Shafiqul Islam; Ilias, Mohammad; Rahman, Mahfuzar; Persson, Lars Ake; Vahter, Marie

    2006-03-01

    The high prevalence of elevated levels of arsenic in drinking-water in many countries, including Bangladesh, has necessitated the development of reliable and rapid methods for the determination of a wide range of arsenic concentrations in water. A simple hydride generation-atomic absorption spectrometry (HG-AAS) method for the determination of arsenic in the range of microg/L to mg/L concentrations in water is reported here. The method showed linearity over concentrations ranging from 1 to 30 microg/L, but requires dilution of samples with higher concentrations. The detection limit ranged from 0.3 to 0.5 microg/L. Evaluation of the method, using internal quality-control (QC) samples (pooled water samples) and spiked internal QC samples throughout the study, and Standard Reference Material in certain lots, showed good accuracy and precision. Analysis of duplicate water samples at another laboratory also showed good agreement. In total, 13,286 tubewell water samples from Matlab, a rural area in Bangladesh, were analyzed. Thirty-seven percent of the water samples had concentrations below 50 microg/L, 29% below the WHO guideline value of 10 microg/L, and 17% below 1 microg/L. The HG-AAS was found to be a precise, sensitive, and reasonably fast and simple method for analysis of arsenic concentrations in water samples.

  20. Palladium Nanoparticles-Based Fluorescence Resonance Energy Transfer Aptasensor for Highly Sensitive Detection of Aflatoxin M₁ in Milk.

    Science.gov (United States)

    Li, Hui; Yang, Daibin; Li, Peiwu; Zhang, Qi; Zhang, Wen; Ding, Xiaoxia; Mao, Jin; Wu, Jing

    2017-10-13

    A highly sensitive aptasensor for aflatoxin M₁ (AFM₁) detection was constructed based on fluorescence resonance energy transfer (FRET) between 5-carboxyfluorescein (FAM) and palladium nanoparticles (PdNPs). PdNPs (33 nm) were synthesized through a seed-mediated growth method and exhibited broad and strong absorption in the whole ultraviolet-visible (UV-Vis) range. The strong coordination interaction between nitrogen functional groups of the AFM₁ aptamer and PdNPs brought FAM and PdNPs in close proximity, which resulted in the fluorescence quenching of FAM to a maximum extent of 95%. The non-specific fluorescence quenching caused by PdNPs towards fluorescein was negligible. After the introduction of AFM₁ into the FAM-AFM₁ aptamer-PdNPs FRET system, the AFM₁ aptamer preferentially combined with AFM₁ accompanied by conformational change, which greatly weakened the coordination interaction between the AFM₁ aptamer and PdNPs. Thus, fluorescence recovery of FAM was observed and a linear relationship between the fluorescence recovery and the concentration of AFM₁ was obtained in the range of 5-150 pg/mL in aqueous buffer with the detection limit of 1.5 pg/mL. AFM₁ detection was also realized in milk samples with a linear detection range from 6 pg/mL to 150 pg/mL. The highly sensitive FRET aptasensor with simple configuration shows promising prospect in detecting a variety of food contaminants.

  1. Censoring: a new approach for detection limits in total-reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Pajek, M. [Institute of Physics, Swietokrzyska Academy, Swietokrzyska 15, 25-406 Kielce (Poland)]. E-mail: pajek@pu.kielce.pl; Kubala-Kukus, A. [Institute of Physics, Swietokrzyska Academy, Swietokrzyska 15, 25-406 Kielce (Poland); Braziewicz, J. [Institute of Physics, Swietokrzyska Academy, Swietokrzyska 15, 25-406 Kielce (Poland)

    2004-08-31

    It is shown that the detection limits in the total-reflection X-ray fluorescence (TXRF), which restrict quantification of very low concentrations of trace elements in the samples, can be accounted for using the statistical concept of censoring. We demonstrate that the incomplete TXRF measurements containing the so-called 'nondetects', i.e. the non-measured concentrations falling below the detection limits and represented by the estimated detection limit values, can be viewed as the left random-censored data, which can be further analyzed using the Kaplan-Meier (KM) method correcting for nondetects. Within this approach, which uses the Kaplan-Meier product-limit estimator to obtain the cumulative distribution function corrected for the nondetects, the mean value and median of the detection limit censored concentrations can be estimated in a non-parametric way. The Monte Carlo simulations performed show that the Kaplan-Meier approach yields highly accurate estimates for the mean and median concentrations, being within a few percent with respect to the simulated, uncensored data. This means that the uncertainties of KM estimated mean value and median are limited in fact only by the number of studied samples and not by the applied correction procedure for nondetects itself. On the other hand, it is observed that, in case when the concentration of a given element is not measured in all the samples, simple approaches to estimate a mean concentration value from the data yield erroneous, systematically biased results. The discussed random-left censoring approach was applied to analyze the TXRF detection-limit-censored concentration measurements of trace elements in biomedical samples. We emphasize that the Kaplan-Meier approach allows one to estimate the mean concentrations being substantially below the mean level of detection limits. Consequently, this approach gives a new access to lower the effective detection limits for TXRF method, which is of prime interest

  2. Real-Time Fluorescence Loop Mediated Isothermal Amplification for the Detection of Acinetobacter baumannii

    Science.gov (United States)

    Wang, Qinqin; Zhou, Yanbin; Li, Shaoli; Zhuo, Chao; Xu, Siqi; Huang, Lixia; Yang, Ling; Liao, Kang

    2013-01-01

    Background Detection of Acinetobacter baumannii has been relying primarily on bacterial culture that often fails to return useful results in time. Although DNA-based assays are more sensitive than bacterial culture in detecting the pathogen, the molecular results are often inconsistent and challenged by doubts on false positives, such as those due to system- and environment-derived contaminations. In addition, these molecular tools require expensive laboratory instruments. Therefore, establishing molecular tools for field use require simpler molecular platforms. The loop-mediated isothermal amplification method is relatively simple and can be improved for better use in a routine clinical bacteriology laboratory. A simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in the same platform has been developed in recent years. This method is referred to as real-time loop-mediated isothermal amplification. In this study, we attempted to utilize this method for rapid detection of A. baumannii. Methodology and Significant Findings Species-specific primers were designed to test the utility of this method. Clinical samples of A. baumannii were used to determine the sensitivity and specificity of this system compared to bacterial culture and a polymerase chain reaction method. All positive samples isolated from sputum were confirmed to be the species of Acinetobacter by 16S rRNA gene sequencing. The RealAmp method was found to be simpler and allowed real-time detection of DNA amplification, and could distinguish A. baumannii from Acinetobacter calcoaceticus and Acinetobacter genomic species 3. DNA was extracted by simple boiling method. Compared to bacterial culture, the sensitivity and specificity of RealAmp in detecting A. baumannii was 98.9% and 75.0%, respectively. Conclusion The RealAmp assay only requires a single unit, and the assay positivity can be verified by visual inspection. Therefore, this assay has

  3. Real-time fluorescence loop mediated isothermal amplification for the detection of Acinetobacter baumannii.

    Directory of Open Access Journals (Sweden)

    Qinqin Wang

    Full Text Available BACKGROUND: Detection of Acinetobacter baumannii has been relying primarily on bacterial culture that often fails to return useful results in time. Although DNA-based assays are more sensitive than bacterial culture in detecting the pathogen, the molecular results are often inconsistent and challenged by doubts on false positives, such as those due to system- and environment-derived contaminations. In addition, these molecular tools require expensive laboratory instruments. Therefore, establishing molecular tools for field use require simpler molecular platforms. The loop-mediated isothermal amplification method is relatively simple and can be improved for better use in a routine clinical bacteriology laboratory. A simple and portable device capable of performing both the amplification and detection (by fluorescence of LAMP in the same platform has been developed in recent years. This method is referred to as real-time loop-mediated isothermal amplification. In this study, we attempted to utilize this method for rapid detection of A. baumannii. METHODOLOGY AND SIGNIFICANT FINDINGS: Species-specific primers were designed to test the utility of this method. Clinical samples of A. baumannii were used to determine the sensitivity and specificity of this system compared to bacterial culture and a polymerase chain reaction method. All positive samples isolated from sputum were confirmed to be the species of Acinetobacter by 16S rRNA gene sequencing. The RealAmp method was found to be simpler and allowed real-time detection of DNA amplification, and could distinguish A. baumannii from Acinetobacter calcoaceticus and Acinetobacter genomic species 3. DNA was extracted by simple boiling method. Compared to bacterial culture, the sensitivity and specificity of RealAmp in detecting A. baumannii was 98.9% and 75.0%, respectively. CONCLUSION: The RealAmp assay only requires a single unit, and the assay positivity can be verified by visual inspection

  4. Mass amplifying probe for sensitive fluorescence anisotropy detection of small molecules in complex biological samples.

    Science.gov (United States)

    Cui, Liang; Zou, Yuan; Lin, Ninghang; Zhu, Zhi; Jenkins, Gareth; Yang, Chaoyong James

    2012-07-03

    Fluorescence anisotropy (FA) is a reliable and excellent choice for fluorescence sensing. One of the key factors influencing the FA value for any molecule is the molar mass of the molecule being measured. As a result, the FA method with functional nucleic acid aptamers has been limited to macromolecules such as proteins and is generally not applicable for the analysis of small molecules because their molecular masses are relatively too small to produce observable FA value changes. We report here a molecular mass amplifying strategy to construct anisotropy aptamer probes for small molecules. The probe is designed in such a way that only when a target molecule binds to the probe does it activate its binding ability to an anisotropy amplifier (a high molecular mass molecule such as protein), thus significantly increasing the molecular mass and FA value of the probe/target complex. Specifically, a mass amplifying probe (MAP) consists of a targeting aptamer domain against a target molecule and molecular mass amplifying aptamer domain for the amplifier protein. The probe is initially rendered inactive by a small blocking strand partially complementary to both target aptamer and amplifier protein aptamer so that the mass amplifying aptamer domain would not bind to the amplifier protein unless the probe has been activated by the target. In this way, we prepared two probes that constitute a target (ATP and cocaine respectively) aptamer, a thrombin (as the mass amplifier) aptamer, and a fluorophore. Both probes worked well against their corresponding small molecule targets, and the detection limits for ATP and cocaine were 0.5 μM and 0.8 μM, respectively. More importantly, because FA is less affected by environmental interferences, ATP in cell media and cocaine in urine were directly detected without any tedious sample pretreatment. Our results established that our molecular mass amplifying strategy can be used to design aptamer probes for rapid, sensitive, and selective

  5. Performance of a Cyanobacteria Whole Cell-Based Fluorescence Biosensor for Heavy Metal and Pesticide Detection

    Directory of Open Access Journals (Sweden)

    Salmijah Surif

    2013-05-01

    Full Text Available Whole cell biosensors always face the challenge of low stability of biological components and short storage life. This paper reports the effects of poly(2-hydroxyethyl methacrylate (pHEMA immobilization on a whole cell fluorescence biosensor for the detection of heavy metals (Cu, Pb, Cd, and pesticides (dichlorophenoxyacetic acid (2,4-D, and chlorpyrifos. The biosensor was produced by entrapping the cyanobacterium Anabaena torulosa on a cellulose membrane, followed by applying a layer of pHEMA, and attaching it to a well. The well was then fixed to an optical probe which was connected to a fluorescence spectrophotometer and an electronic reader. The optimization of the biosensor using several factors such as amount of HEMA and drying temperature were undertaken. The detection limits of biosensor without pHEMA for Cu, Cd, Pb, 2,4-D and chlorpyrifos were 1.195, 0.027, 0.0100, 0.025 and 0.025 µg/L respectively. The presence of pHEMA increased the limits of detection to 1.410, 0.250, 0.500, 0.235 and 0.117 µg/L respectively. pHEMA is known to enhance the reproducibility of the biosensor with average relative standard deviation (RSD of ±1.76% for all the pollutants tested, 48% better than the biosensor without pHEMA (RSD = ±3.73%. In storability test with Cu 5 µg/L, the biosensor with pHEMA performed 11.5% better than the test without pHEMA on day-10 and 5.2% better on day-25. pHEMA is therefore a good candidate to be used in whole cell biosensors as it increases reproducibility and enhances biosensor storability.

  6. Detection and Analysis of Enamel Cracks by Quantitative Light-induced Fluorescence Technology.

    Science.gov (United States)

    Jun, Mi-Kyoung; Ku, Hye-Min; Kim, Euiseong; Kim, Hee-Eun; Kwon, Ho-Keun; Kim, Baek-Il

    2016-03-01

    The ability to accurately detect tooth cracks and quantify their depth would allow the prediction of crack progression and treatment success. The aim of this in vitro study was to determine the capabilities of quantitative light-induced fluorescence (QLF) technology in the detection of enamel cracks. Ninety-six extracted human teeth were selected for examining naturally existing or suspected cracked teeth surfaces using a photocuring unit. QLF performed with a digital camera (QLF-D) images were used to assess the ability to detect enamel cracks based on the maximum fluorescence loss value (ΔFmax, %), which was then analyzed using the QLF-D software. A histologic evaluation was then performed in which the samples were sectioned and observed with the aid of a polarized light microscope. The relationship between ΔFmax and the histology findings was assessed based on the Spearman rank correlation. The sensitivity and specificity were calculated to evaluate the validity of using QLF-D to analyze enamel inner-half cracks and cracks extending to the dentin-enamel junction. There was a strong correlation between the results of histologic evaluations of enamel cracks and the ΔFmax value, with a correlation coefficient of 0.84. The diagnostic accuracy of QLF-D had a sensitivity of 0.87 and a specificity of 0.98 for enamel inner-half cracks and a sensitivity of 0.90 and a specificity of 1.0 for cracks extending to the dentin-enamel junction. These results indicate that QLF technology would be a useful clinical tool for diagnosing enamel cracks, especially given that this is a nondestructive method. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Histological validation of a laser fluorescence device for occlusal caries detection in primary molars.

    Science.gov (United States)

    Apostolopoulou, D; Lagouvardos, P; Kavvadia, K; Papagiannoulis, L

    2009-11-01

    This was to validate in vitro a laser fluorescence device, DIAGNOdent 2095 - DD, on the detection of occlusal caries in primary molars using the histological examination as the gold standard and to compare the laser fluorescence findings to the results of the conventionally used diagnostic methods. 111 occlusal pits in 24 extracted primary molars were examined for caries by one trained operator (Intra-examiner Reliability K>0.83), using direct visual (DV), indirect visual (IDV), radiographic (XR) and fluorescence (DD) examinations and then the extent of caries was determined histologically. Sensitivity, specificity, accuracy and the area under the ROC curve - AUC were calculated for all methods, using the histological evaluation as the gold standard. Differences between examination methods were estimated by pair-wise comparison of their respective AUC. DD's sensitivity for enamel and for dentine lesions respectively was 0.90 and 0.36, its specificity 0.36 and 0.91 and its accuracy 0.61 and 0.65. The DD device exhibited better sensitivity than specificity for enamel lesions and better specificity than sensitivity for lesions into dentine. The DD device was found to have the highest sensitivity for lesions into enamel, specificity and accuracy and as well as the largest AUC compared with all other methods. For lesions into dentine however, according to AUC values the DD was not statistically significant different from the other methods. Compared with the other methods, the DD had the highest validity for enamel caries while its validity for caries into dentine was not statistical different from the other methods.

  8. The effect of distance and tooth structure on laser fluorescence caries detection.

    Science.gov (United States)

    Markowitz, K; Stenvall, R M; Graye, M

    2012-01-01

    The DIAGNOdent, a device used in caries detection, uses a laser to excite fluorescence from pigments in carious tooth structure. In clinical use assessing occlusal surfaces, distance and tooth structure may separate the instrument's tip from the fluorescent source.The aim of this in vitro study was to examine the effect of distance and tooth structure on laser fluorescence (LF) readings.In one set of experiments, a porphyrin pigmentin oil suspension was used as a LF signal source. Thin slices of enamel and dentin were obtained from extracted molars. Pigment-induced LF readings were obtained when these slices were placed between the porphyrin pigment and the LF instrument's tip. The effect of either demineralized or intact tooth tissue on pigment-induced LF readings was assessed.In other experiments on extracted molars with small occlusal caries, LF readings were taken from pit/fissure sites before and after removal of the occlusal surface.LF readings are proportional to pigment con-centration and inversely proportional to the distance between the suspension and the instrument's tip. Enamel, demineralized enamel,dentin, and demineralized dentin all caused significant reductions in LF signal, all readings being taken with the same tip-pigment distance. Demineralized enamel (white with intact surface) caused the most reduction.After sectioning of carious teeth, there was a significant increase in LF readings.The results of this study indicate that distance and the presence of tooth structure between the carious lesion and the instrument's tip reduce LF readings. These results indicate that anatomic factors interfere with the LF device's ability to assess occlusal caries. DIAGNOdent readings should not be relied on when making diagnostic decisions.

  9. Censoring approach to the detection limits in X-ray fluorescence analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pajek, M. [Institute of Physics, Swietokrzyska Academy, Swietokrzyska 15, 25-406 Kielce (Poland)]. E-mail: pajek@pu.kielce.pl; Kubala-Kukus, A. [Institute of Physics, Swietokrzyska Academy, Swietokrzyska 15, 25-406 Kielce (Poland)

    2004-10-08

    We demonstrate that the effect of detection limits in the X-ray fluorescence analysis (XRF), which limits the determination of very low concentrations of trace elements and results in appearance of the so-called 'nondetects', can be accounted for using the statistical concept of censoring. More precisely, the results of such measurements can be viewed as the left random censored data, which can further be analyzed using the Kaplan-Meier method correcting the data for the presence of nondetects. Using this approach, the results of measured, detection limit censored concentrations can be interpreted in a nonparametric manner including the correction for the nondetects, i.e. the measurements in which the concentrations were found to be below the actual detection limits. Moreover, using the Monte Carlo simulation technique we show that by using the Kaplan-Meier approach the corrected mean concentrations for a population of the samples can be estimated within a few percent uncertainties with respect of the simulated, uncensored data. This practically means that the final uncertainties of estimated mean values are limited in fact by the number of studied samples and not by the correction procedure itself. The discussed random-left censoring approach was applied to analyze the XRF detection-limit-censored concentration measurements of trace elements in biomedical samples.

  10. Pen-type laser fluorescence device versus bitewing radiographs for caries detection on approximal surfaces.

    Science.gov (United States)

    Bizhang, M; Wollenweber, N; Singh-Hüsgen, P; Danesh, G; Zimmer, S

    2016-11-04

    The accurate detection of approximal caries is generally difficult. The aim of this study was to assess the ability of the pen-type laser fluorescence device (LF pen) to detect approximal carious lesions in comparison to bitewing radiographs (BW). Three hundred forty-one tooth surfaces were diagnosed in 20 patients with an average age of 26.70 (±2.82) years. Each test tooth was sequentially assessed by a single calibrated examiner using visual inspection, BW, and the LF pen. Radiographs were used as the gold standard to calculate an appropriate cut-off. Sensitivity, specificity and accuracy values for cut-off limits of 15, measured by the LF pen were compared using the chi 2 test (McNemar test). For approximal caries at D3 level, the highest values of specificity and sensitivity were observed for the LF pen at a cut-off value of 15 (96.8 and 83.0 %) and for visual inspection (99.3 and 4.3 %). Within the limitations of this study, dentin caries on approximal surfaces could be detected equally well by the LF pen as by the bitewing radiographs. Therefore, the LF pen can be recommended as an alternative to radiographs for the detection of approximal caries in a regular dental practice setting. DRKS00004817 on DRKS on 12 th March 2013.

  11. Development and Testing of an Air Fluorescence Imaging System for the Detection of Radiological Contamination

    International Nuclear Information System (INIS)

    Inrig, Elizabeth; Koslowsky, Vern; Andrews, Bob; Dick, Michael; Forget, Patrick; Ing, Harry; Hugron, Roger; Wong, Larry

    2011-01-01

    Detection of radionuclides emitting short-range radiation, such as α and low-energy β particles, has always presented a challenge, particularly when such radionuclides are dispersed over a wide area. In this situation, conventional detection methods require the area of interest to be surveyed using a fragile probe at very close range--a slow, error-prone, and potentially dangerous process that may take many hours for a single room. The instrument under development uses a novel approach by imaging radiation-induced fluorescence in the air surrounding a contaminated area, rather than detecting the radiation directly. A robust and portable system has been designed and built that will allow contaminated areas to be rapidly detected and delineated. The detector incorporates position-sensitive photo-multiplier tubes, UV filters, a fast electronic shutter and an aspherical phase mask that significantly increases the depth-of-field. Preliminary tests have been conducted using sealed 241 Am sources of varying activities and surface areas. The details of the instrument design will be described and the results of recent testing will be presented.

  12. Validation of the chlorophyll fluorescence imaging method (CFI for early detection of herbicide resistance in weeds

    Directory of Open Access Journals (Sweden)

    Menegat, Alexander

    2014-02-01

    Full Text Available The increasing number of herbicide tolerant weed populations is illustrating the increasing demand for reliable methods for an accelerated detection of herbicide tolerance compared to greenhouse studies. Several methods for resistance quick detection have been published in previous years. One of the recent methods is the Chlorophyll Fluorescence Imaging Method (CFI. For this method changes in photosynthetic activity of the target organisms, caused by herbicides, are determined. General assumption of this method in terms of herbicide resistance detection is that each herbicidal compound, independent of the mode of action, will cause changes within the photosynthetic apparatus of the target organisms. This effect already could be confirmed for several modes of action (PSII, ALS, ACCase, EPSPS, synth. Auxins. Aim of this study is to validate this novel method on the basis of greenhouse experiments and single nucleotide polymorphisms (SNP analysis. The resistance profiles of 10 black-grass populations (Alopecurus myosuroides Huds. have been determined in greenhouse herbicide efficacy trials and constitutive SNP analyses of the survivors. With the CFI-method it was possible to detect the resistance profile as well as the resistance frequency within the populations. The results from the greenhouse experiments could be reproduced with conformity of 94%. This result is valid for the tested herbicides mesosulfuron, pyroxsulam as well as clodinafop and pinoxaden.

  13. Fluorescence In Situ Hybridization for MicroRNA Detection in Archived Oral Cancer Tissues

    Directory of Open Access Journals (Sweden)

    Zonggao Shi

    2012-01-01

    Full Text Available The noncoding RNA designated as microRNA (miRNA is a large group of small single-stranded regulatory RNA and has generated wide-spread interest in human disease studies. To facilitate delineating the role of microRNAs in cancer pathology, we sought to explore the feasibility of detecting microRNA expression in formalin-fixed paraffin-embedded (FFPE tissues. Using FFPE materials, we have compared fluorescent in situ hybridization (FISH procedures to detect miR-146a with (a different synthetic probes: regular custom DNA oligonucleotides versus locked nucleic acid (LNA incorporated DNA oligonucleotides; (b different reporters for the probes: biotin versus digoxigenin (DIG; (c different visualization: traditional versus tyramide signal amplification (TSA system; (d different blocking reagents for endogenous peroxidase. Finally, we performed miR-146a FISH on a commercially available oral cancer tissue microarray, which contains 40 cases of oral squamous cell carcinoma (OSCC and 10 cases of normal epithelia from the human oral cavity. A sample FISH protocol for detecting miR-146a is provided. In summary, we have established reliable in situ hybridization procedures for detecting the expression of microRNA in FFPE oral cancer tissues. This method is an important tool for studies on the involvement of microRNA in oral cancer pathology and may have potential prognostic or diagnostic value.

  14. High sensitivity detection of selenium by laser excited atomic fluorescence spectrometry using electrothermal atomization

    International Nuclear Information System (INIS)

    Heitmann, U.; Hese, A.; Schoknecht, G.; Gries, W.

    1995-01-01

    The high sensitivity detection of the trace element selenium is reported. The analytical method applied is Laser Excited Atomic Fluorescence Spectrometry using Electrothermal Atomization within a graphite furnace atomizer. For the production of tunable laser radiation in the VUV spectral region a laser system was developed which consists of two dye lasers pumped by a Nd:YAG laser. The laser radiations are subsequently frequency doubled and sum frequency mixed by nonlinear optical KDP or BBO crystals, respectively. The system works with a repetition rate of 20 Hz and provides output energies of up to 100 μJ in the VUV at a pulse duration of 5 ns. The analytical investigations were focused on the detection of selenium in aqueous solutions and samples of human whole blood. From measurements on aqueous standards detection limits of 1.5 ng/l for selenium were obtained, with corresponding absolute detected masses of only 15 fg. The linear dynamic range spanned six orders of magnitude and good precision was achieved. In case of human whole blood samples the recovery was found to be within the range of 96% to 104%. The determination of the selenium content yielded medians of [119.5 ± 17.3] μg/l for 200 frozen blood samples taken in 1988 and [109.1 ± 15.6] μg/l for 103 fresh blood samples. (author)

  15. Graphitic Carbon Nitride Nanosheets-Based Ratiometric Fluorescent Probe for Highly Sensitive Detection of H2O2 and Glucose.

    Science.gov (United States)

    Liu, Jin-Wen; Luo, Ying; Wang, Yu-Min; Duan, Lu-Ying; Jiang, Jian-Hui; Yu, Ru-Qin

    2016-12-14

    Graphitic carbon nitride (g-C 3 N 4 ) nanosheets, an emerging graphene-like carbon-based nanomaterial with high fluorescence and large specific surface areas, hold great potential for biosensor applications. Current g-C 3 N 4 nanosheets based fluorescent biosensors majorly rely on single fluorescent intensity reading through fluorescence quenching interactions between the nanosheets and metal ions. Here we report for the first time the development of a novel g-C 3 N 4 nanosheets-based ratiometric fluorescence sensing strategy for highly sensitive detection of H 2 O 2 and glucose. With o-phenylenediamine (OPD) oxidized by H 2 O 2 in the presence of horseradish peroxidase (HRP), the oxidization product can assemble on the g-C 3 N 4 nanosheets through hydrogen bonding and π-π stacking, which effectively quenches the fluorescence of g-C 3 N 4 while delivering a new emission peak. The ratiometric signal variations enable robust and sensitive detection of H 2 O 2 . On the basis of the glucose converting into H 2 O 2 through the catalysis of glucose oxidase, the g-C 3 N 4 -based ratiometric fluorescence sensing platform is also exploited for glucose assay. The developed strategy is demonstrated to give a detection limit of 50 nM for H 2 O 2 and 0.4 μM for glucose, at the same time, it has been successfully used for glucose levels detection in human serum. This strategy may provide a cost-efficient, robust, and high-throughput platform for detecting various species involving H 2 O 2 -generation reactions for biomedical applications.

  16. Arsenic Speciation of Waters from the Aegean Region, Turkey by Hydride Generation: Atomic Absorption Spectrometry.

    Science.gov (United States)

    Çiftçi, Tülin Deniz; Henden, Emur

    2016-08-01

    Arsenic in drinking water is a serious problem for human health. Since the toxicity of arsenic species As(III) and As(V) is different, it is important to determine the concentrations separately. Therefore, it is necessary to develop an accurate and sensitive method for the speciation of arsenic. It was intended with this work to determine the concentrations of arsenic species in water samples collected from Izmir, Manisa and nearby areas. A batch type hydride generation atomic absorption spectrometer was used. As(V) gave no signal under the optimal measurement conditions of As(III). A certified reference drinking water was analyzed by the method and the results showed excellent agreement with the reported values. The procedure was applied to 34 water samples. Eleven tap water, two spring water, 19 artesian well water and two thermal water samples were analyzed under the optimal conditions.

  17. Light-emitting diode and laser fluorescence-based devices in detecting occlusal caries

    Science.gov (United States)

    Rodrigues, Jonas A.; Hug, Isabel; Neuhaus, Klaus W.; Lussi, Adrian

    2011-10-01

    The aim of this study was to assess the performance of two light-emitting diode (LED)- and two laser fluorescence-based devices in detecting occlusal caries in vitro. Ninety-seven permanent molars were assessed twice by two examiners using two LED- (Midwest Caries - MID and VistaProof - VP) and two laser fluorescence-based (DIAGNOdent 2095 - LF and DIAGNOdent pen 2190 - LFpen) devices. After measuring, the teeth were histologically prepared and classified according to lesion extension. At D1 the specificities were 0.76 (LF and LFpen), 0.94 (MID), and 0.70 (VP); the sensitivities were 0.70 (LF), 0.62 (LFpen), 0.31 (MID), and 0.75 (VP). At D3 threshold the specificities were 0.88 (LF), 0.87 (LFpen), 0.90 (MID), and 0.70 (VP); the sensitivities were 0.63 (LF and LFpen), 0.70 (MID), and 0.96 (VP). Spearman's rank correlations with histology were 0.56 (LF), 0.51 (LFpen), 0.55 (MID), and 0.58 (VP). Inter- and intraexaminer ICC values were high and varied from 0.83 to 0.90. Both LF devices seemed to be useful auxiliary tools to the conventional methods, presenting good reproducibility and better accuracy at D3 threshold. MID was not able to differentiate sound surfaces from enamel caries and VP still needs improvement on the cut-off limits for its use.

  18. Thiophene Appended Dual Fluorescent Sensor for Detection of Hg2+and Cysteamine.

    Science.gov (United States)

    Sarkar, Soma; Roy, Swapnadip; Saha, R N; Panja, Sujit S

    2018-01-01

    An efficient and highly selective pyrene-thiophene conjugate has been reported as a dual sensor for Hg 2+ and cysteamine (an important drug for genetic disorder). The sensor displays a turn-on fluorescence response towards Hg 2+ in a 2:1 stoichiometric ratio via excimer formation with a detection limit as low as of 30.6 nM. The excimer emission upon binding with Hg 2+ has been rationalized by experimental as well as theoritical studies. Moreover, the [probe-Hg 2+ ] adduct functions as an efficient sensor for cysteamine. This sensing process happens via the extraction of Hg 2+ from the adduct. In this paper, change in emission properties of the receptor with varying pH and water content has also been explained. The sensing abilities of the sensor were examined in real water sample analysis. Therefore, the sensor can be used as an efficient and reusable fluorescent sensor for recognition of Hg 2+ in water.

  19. Fluorescence turn-on detection of Sn2+ in live eukaryotic and prokaryotic cells.

    Science.gov (United States)

    Lan, Haichuang; Wen, Ying; Shi, Yunming; Liu, Keyin; Mao, Yueyuan; Yi, Tao

    2014-10-21

    Sn(2+) is usually added to toothpaste to prevent dental plaque and oral disease. However, studies of its physiological role and bacteriostatic mechanism are restricted by the lack of versatile Sn(2+) detection methods applicable to live cells, including Streptococcus mutans. Here we report two Sn(2+) fluorescent probes containing a rhodamine B derivative as a fluorophore, linked via the amide moiety to N,N-bis(2-hydroxyethyl)ethylenediamine (R1) and tert-butyl carbazate group (R2), respectively. These probes can selectively chelate Sn(2+) and show marked fluorescence enhancement due to the ring open reaction of rhodamine induced by Sn(2+) chelation. The probes have high sensitivity and selectivity for Sn(2+) in the presence of various relevant metal ions. Particularly, both R1 and R2 can target lysosomes, and R2 can probe Sn concentrations in lysosomes with rather acidic microenvironment. Furthermore, these two probes have low toxicity and can be used as imaging probes for monitoring Sn(2+) not only in live KB cells (eukaryotic) but also in Streptococcus mutans cells (prokaryotic), which is a useful tool to study the physiological function of Sn(2+) in biological systems.

  20. KF polymerase-based fluorescence aptasensor for the label-free adenosine detection.

    Science.gov (United States)

    Liao, Dongli; Jiao, Huping; Wang, Bin; Lin, Quan; Yu, Cong

    2012-02-21

    We have developed a simple, inexpensive, and label-free method for the selective detection of adenosine. Klenow fragment polymerase (KF polymerase) is a commonly-used 5' to 3' DNA polymerase, it also has 3' to 5' exonuclease activity that can digest single-stranded DNA. An adenosine binding DNA aptamer was employed, the aptamer was split into two pieces of single-stranded DNA (aptamer-A1 + aptamer-A2). Without the addition of adenosine, aptamer-A1 and aptamer-A2 existed as single-stranded DNA which could be efficiently degraded by the exonuclease activity of KF polymerase. Much reduced background fluorescence was obtained when SYBR Green dye was added. However, in the presence of adenosine, aptamer-A1 and aptamer-A2 bound to adenosine, and hybridization of the complementary sequences resulted in the formation of a duplex DNA structure, which could initiate DNA polymerization. The addition of SYBR Green dye resulted in a very high fluorescence enhancement, which could be used for the quantification of adenosine.

  1. Determination of the carbohydrates from Notopterygium forbesii Boiss by HPLC with fluorescence detection.

    Science.gov (United States)

    Zhang, Shijuan; Li, Chunli; Zhou, Guoying; Che, Guodong; You, Jinmao; Suo, Yourui

    2013-09-12

    A sensitive pre-column derivatization method was developed for analysis of carbohydrates by HPLC with fluorescence detection. The introduction of 2-(12-benzo[b]acridin-5(12H)-yl)-acetohydrazide (BAAH) with excellent fluorescence property into the molecules of monosaccharides greatly enhanced the HPLC sensitivity of the analytes. Meanwhile, derivatization with BAAH also greatly increased the hydrophobicity of the monosaccharides and made them elute at increased retention times. The monosaccharides with similar properties therefore could be completely separated due to the increased interaction between the analytes and the column. Component monosaccharides of the polysaccharides obtained from the roots, stems and leaves of Notopterygium forbesii Boiss (NF) were analyzed by the developed method. The results indicated that the polysaccharides of NF were mainly composed of d-galactose and d-glucose. This is the first systematic study of the sugar composition of the polysaccharides of NF. It will be helpful for the quality control of NF. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Fluorescence detection, enumeration and characterization of single circulating cells in vivo: technology, applications and future prospects

    Science.gov (United States)

    Hartmann, Carolin; Patil, Roshani; Lin, Charles P.; Niedre, Mark

    2018-01-01

    There are many diseases and biological processes that involve circulating cells in the bloodstream, such as cancer metastasis, immunology, reproductive medicine, and stem cell therapies. This has driven significant interest in new technologies for the study of circulating cells in small animal research models and clinically. Most currently used methods require drawing and enriching blood samples from the body, but these suffer from a number of limitations. In contrast, ‘in vivo flow cytometry’ (IVFC) refers to set of technologies that allow study of cells directly in the bloodstream of the organism in vivo. In recent years the IVFC field has grown significantly and new techniques have been developed, including fluorescence microscopy, multi-photon, photo-acoustic, and diffuse fluorescence IVFC. In this paper we review recent technical advances in IVFC, with emphasis on instrumentation, contrast mechanisms, and detection sensitivity. We also describe key applications in biomedical research, including cancer research and immunology. Last, we discuss future directions for IVFC, as well as prospects for broader adoption by the biomedical research community and translation to humans clinically.

  3. Development of new photon detection device for Cherenkov and fluorescence radiation

    Directory of Open Access Journals (Sweden)

    Tinti A.

    2013-06-01

    Full Text Available Recent progress on the development of a new solid state detector allowed the use of finely pixelled photocathodes obtained from silicon semiconductors. SiPM detectors seem to be an ideal tool for the detection of Cherenkov and fluorescence light in spite of their not yet resolved criticism for operating temperature and intrinsic noise. The main disadvantage of SiPM in this case is the poor sensitivity in the wavelength range 300-400 nm, where the Cherenkov light and fluorescence radiation are generated. We report on the possibility to realize a new kind of pixelled photodetector based on the use of silicon substrate with carbon nanotube compounds, more sensitive to the near UV radiation. Also if at the very beginning, the development of such detector appears very promising and useful for astroparticle physics, both in the ground based arrays and in the space experiments. The detectors are ready to be operated in conditions of measurements without signal amplification.

  4. Easy and Rapid Detection of Mumps Virus by Live Fluorescent Visualization of Virus-Infected Cells.

    Directory of Open Access Journals (Sweden)

    Tadanobu Takahashi

    Full Text Available Mumps viruses show diverse cytopathic effects (CPEs of infected cells and viral plaque formation (no CPE or no plaque formation in some cases depending on the viral strain, highlighting the difficulty in mumps laboratory studies. In our previous study, a new sialidase substrate, 2-(benzothiazol-2-yl-4-bromophenyl 5-acetamido-3,5-dideoxy-α-D-glycero-D-galacto-2-nonulopyranosidonic acid (BTP3-Neu5Ac, was developed for visualization of sialidase activity. BTP3-Neu5Ac can easily and rapidly perform histochemical fluorescent visualization of influenza viruses and virus-infected cells without an antiviral antibody and cell fixation. In the present study, the potential utility of BTP3-Neu5Ac for rapid detection of mumps virus was demonstrated. BTP3-Neu5Ac could visualize dot-blotted mumps virus, virus-infected cells, and plaques (plaques should be called focuses due to staining of infected cells in this study, even if a CPE was not observed. Furthermore, virus cultivation was possible by direct pick-up from a fluorescent focus. In conventional methods, visible appearance of the CPE and focuses often requires more than 6 days after infection, but the new method with BTP3-Neu5Ac clearly visualized infected cells after 2 days and focuses after 4 days. The BTP3-Neu5Ac assay is a precise, easy, and rapid assay for confirmation and titration of mumps virus.

  5. An LED light source and novel fluorophore combinations improve fluorescence laparoscopic detection of metastatic pancreatic cancer in orthotopic mouse models.

    Science.gov (United States)

    Metildi, Cristina A; Kaushal, Sharmeela; Lee, Claudia; Hardamon, Chanae R; Snyder, Cynthia S; Luiken, George A; Talamini, Mark A; Hoffman, Robert M; Bouvet, Michael

    2012-06-01

    The aim of this study was to improve fluorescence laparoscopy of pancreatic cancer in an orthotopic mouse model with the use of a light-emitting diode (LED) light source and optimal fluorophore combinations. Human pancreatic cancer models were established with fluorescent FG-RFP, MiaPaca2-GFP, BxPC-3-RFP, and BxPC-3 cancer cells implanted in 6-week-old female athymic mice. Two weeks postimplantation, diagnostic laparoscopy was performed with a Stryker L9000 LED light source or a Stryker X8000 xenon light source 24 hours after tail-vein injection of CEA antibodies conjugated with Alexa 488 or Alexa 555. Cancer lesions were detected and localized under each light mode. Intravital images were also obtained with the OV-100 Olympus and Maestro CRI Small Animal Imaging Systems, serving as a positive control. Tumors were collected for histologic analysis. Fluorescence laparoscopy with a 495-nm emission filter and an LED light source enabled real-time visualization of the fluorescence-labeled tumor deposits in the peritoneal cavity. The simultaneous use of different fluorophores (Alexa 488 and Alexa 555), conjugated to antibodies, brightened the fluorescence signal, enhancing detection of submillimeter lesions without compromising background illumination. Adjustments to the LED light source permitted simultaneous detection of tumor lesions of different fluorescent colors and surrounding structures with minimal autofluorescence. Using an LED light source with adjustments to the red, blue, and green wavelengths, it is possible to simultaneously identify tumor metastases expressing fluorescent proteins of different wavelengths, which greatly enhanced the signal without compromising background illumination. Development of this fluorescence laparoscopy technology for clinical use can improve staging and resection of pancreatic cancer. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  6. A sensitive turn on fluorescent probe for detection of biothiols using MnO2@carbon dots nanocomposites

    Science.gov (United States)

    Garg, Dimple; Mehta, Akansha; Mishra, Amit; Basu, Soumen

    2018-03-01

    Presently, the combination of carbon quantum dots (CQDs) and metal oxide nanostructures in one frame are being considered for the sensing of purine compounds. In this work, a combined system of CQDs and MnO2 nanostructures was used for the detection of anticancer drugs, 6-Thioguanine (6-TG) and 6-Mercaptopurine (6-MP). The CQDs were synthesized through microwave synthesizer and the MnO2 nanostructures (nanoflowers and nanosheets) were synthesized using facile hydrothermal technique. The CQDs exhibited excellent fluorescence emission at 420 nm when excited at 320 nm wavelength. By combining CQDs and MnO2 nanostructures, quenching of fluorescence was observed which was attributed to fluorescence resonance energy transfer (FRET) mechanism, where CQDs act as electron donor and MnO2 act as acceptor. This fluorescence quenching behaviour disappeared on the addition of 6-TG and 6-MP due to the formation of Mn-S bond. The detection limit for 6-TG (0.015 μM) and 6-MP (0.014 μM) was achieved with the linear range of concentration (0-50 μM) using both MnO2 nanoflowers and nanosheets. Moreover, the as-prepared fluorescence-sensing technique was successfully employed for the detection of bio-thiol group in enapril drug. Thus a facile, cost-effective and benign chemistry approach for biomolecule detection was designed.

  7. Trifunctional fluorescent unnatural nucleoside: Label free detection of T-T/C-C base mismatches, abasic site and bulge DNA.

    Science.gov (United States)

    Bag, Subhendu Sekhar; Pradhan, Manoj Kumar; Talukdar, Sangita

    2017-08-01

    The detection and targeting of both the mismatched and abasic DNA is highly important which would ultimately help in designing new diagnostics and chemotherapeutics. Furthermore, sensing and targeting the bulge sequence with a fluorescent probe would be useful to study the role of bulges in nucleic acid function or could have significant therapeutic potential. Thus, detection of specific bulges by small fluorescent molecules is an attractive research area since the past several years. Many attempts have been made to prepare such compounds. We report herein a label free strategy for the detection of pyrimidine base mismatches (T/T and C/C), sensing of abasic site, and pyrimidine base bulge DNA using an unnatural tetrazolylpyrene nucleoside ( TPy B Do ) as a bare fluorescent probe. The H-bonding/hydrophobic force mediated interactions allow the sensing of all three deformed DNA via an enhancement of fluorescence signal using our simple "Just-Mix and Read" strategy. The binding of the probe to all the three deformed DNA duplexes is accompanied by an increase in the thermal melting stability of the deformed DNAs. That the probe binds efficiently to the minor groove near the deformed site was evident from spectroscopic studies. All the spectral evidences open up a multitude of possibilities for using our probe, tetrazolylpyrene nucleoside, as an efficient fluorescent light-up bio-probe for label free DNA detection. Copyright © 2017. Published by Elsevier B.V.

  8. Fluorescence visualization efficacy for detecting oral lesions more prone to be dysplastic and potentially malignant disorders: a pilot study.

    Science.gov (United States)

    Simonato, Luciana Estevam; Tomo, Saygo; Miyahara, Glauco Issamu; Navarro, Ricardo Scarparo; Villaverde, Antonio Guillermo Jose Balbin

    2017-03-01

    To analyze the efficacy of fluorescence visualization in early detection of oral early neoplastic processes when used by an inexperienced and an adept oral examiner. A dental student and an expert professional in oral diagnosis examined 15 randomly selected patients using conventional oral examination and fluorescence visualization searching for early signs of epithelial dysplasia and oral potentially malignant disorders. Patients detected with oral lesions in any of examinations were submitted to incisional biopsy for definitive diagnosis. Taking histopathologic analysis as Gold Standard, sensitivity, specificity, positive and negative predictive values and accuracy of inexperienced examiner for detecting both epithelium dysplasia and oral potentially malignant disorders increased when using fluorescence visualization compared to conventional white light examination, matching the same values found for expert professional in oral diagnosis. Furthermore, it was possible to observe discrete increase in the efficacy of expert professional's examination when using fluorescence visualization. This study indicates fluorescence visualization is capable of improve inexperienced professionals' efficacy for early detecting oral lesions more prone to be dysplastic and oral potentially malignant disorders. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Rapid Simultaneous Amplification and Detection of the MBR/JH Chromosomal Translocation by Fluorescence Melting Curve Analysis

    Science.gov (United States)

    Bohling, Sandra D.; King, Thomas C.; Wittwer, Carl T.; Elenitoba-Johnson, Kojo S. J.

    1999-01-01

    Polymerase chain reaction (PCR) amplification and product analysis for the detection of chromosomal translocations, such as the t(14;18), has traditionally been a two-step process. PCR product detection has generally entailed gel electrophoresis and/or hybridization or sequencing for confirmation of assay specificity. Using a microvolume fluorimeter integrated with a thermal cycler and a PCR-compatible double-stranded DNA (dsDNA) binding fluorescent dye (SYBR Green I), we investigated the feasibility of simultaneous thermal amplification and detection of MBR/JH translocation products by fluorescence melting curve analysis. We analyzed DNA from 30 cases of lymphoproliferative disorders comprising 19 cases of previously documented MBR/JH-positive follicle center lymphoma and 11 reactive lymphadenopathies. The samples were coded and analyzed blindly for the presence of MBR/JH translocations by fluorescence melting curve analysis. We also performed dilutional assays using the MBR/JH-positive cell line SUDHL-6. Multiplex PCR for MBR/JH and β-globin was used to simultaneously assess sample adequacy. All (100%) of the 19 cases previously determined to be MBR/JH positive by conventional PCR analysis showed a characteristic sharp decrease in fluorescence at ∼90°C by melting curve analysis after amplification. Fluorescence melting peaks obtained by plotting the negative derivative of fluorescence over temperature (−dF/dT) versus temperature (T) showed melting temperatures (Tm) at 88.85 ± 1.15°C. In addition, multiplex assays using both MBR/JH and β-globin primers yielded easily distinguishable fluorescence melting peaks at ∼90°C and 81.2°C, respectively. Dilutional assays revealed that fluorescence melting curve analysis was more sensitive than conventional PCR and agarose gel electrophoresis with ultraviolet transillumination by as much as 100-fold. Simultaneous amplification and fluorescence melting curve analysis is a simple, reliable, and sensitive method

  10. Polychromatic excitation improves detection limits in total reflection X-ray fluorescence analysis compared with monochromatic excitation.

    Science.gov (United States)

    Kunimura, Shinsuke; Kawai, Jun

    2010-08-01

    Detection limits obtained by a portable total reflection X-ray fluorescence (TXRF) spectrometer with or without a monochromator are compared. A 1 W X-ray tube (tube voltage: 20 kV) is used in this spectrometer. Polychromatic excitation improves the detection limits in TXRF analysis with the low power X-ray tube compared with monochromatic excitation. A detection limit of 26 pg is achieved for Co when using the weak polychromatic X-rays.

  11. Determination of ochratoxin A in coriander (Coriandrum sativum L. by HPCL/fluorescence detection

    Directory of Open Access Journals (Sweden)

    Celeste Matos Lino

    2006-06-01

    Full Text Available An analytical study based on extraction with acetonitrile-water, immunoaffinity column cleanup, and HPLC/fluorescence detection for separation and identification of ochratoxin A in coriander was carried out. Validation of the applied methodology was done through accuracy and precision studies. Homogenized samples of coriander were spiked in triplicate with ochratoxin A at 0.5, 1.0, 2.0, and 5.0 µg/kg levels. Recovery values were in the range of 98% for a fortification level at 0.5 µg/kg to 109.1% at 1.0 µg/kg. Application to coriander samples available in Portuguese markes showed no contamination with ochratoxin A.

  12. Structure and dynamics of olefin radical cation aggregates. Time-resolved fluorescence detected magnetic resonance

    International Nuclear Information System (INIS)

    Desrosiers, M.F.; Trifunac, A.D.

    1986-01-01

    The time-resolved EPR spectra and thus the structure and dynamics of transient hydrocarbon radical cations are obtained by the pulse radiolysis-fluorescence detected magnetic resonance (FDMR) technique. Here the authors report the observation of short-lived radical cations from olefins. FDMR-EPR spectra of radical cations from tetramethylethylene and cyclohexadiene are illustrated. The olefin radical cations, FDMR spectra are concentration-dependent, since dimerization with neutral molecules takes place at higher (>10 -2 M) olefin concentration. Rate constants for the dimerization reaction are derived and the effect of solvent viscosity on aggregate formation is demonstrated. By monitoring the further reactions of dimer cations the authors have obtained EPR evidence for previously unobserved higher-order (multimer) radical cation aggregates of olefins. 16 references, 5 figures

  13. Complexing membrane for uranium detection by total reflection X-ray fluorescence.

    Science.gov (United States)

    Hatzistavros, Vasilios; Koulouridakis, Pavlos; Kallithrakas-Kontost, Nikolaos

    2005-07-01

    Selective membranes containing a few micrograms of various complexing reagents in a polyvinyl chloride (PVC) matrix were produced in order to determine low uranium concentrations in water. The membranes were produced on the surfaces of quartz glasses, and immersed in water solutions containing uranium salts (5 - 50 ng/mL). By the end of the equilibration time, the membranes were left to dry and analyzed based on the total reflection X-ray fluorescence. The effects of the complexing agents and their mass proportions added in the membranes were studied. The combination of the complexing reagents dithizone and thiourea gave the best result. The minimum detection limit was measured to be equal to 0.8 ng/mL.

  14. Laser-Induced Fluorescence Detection in High-Throughput Screening of Heterogeneous Catalysts and Single Cells Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Su, Hui [Iowa State Univ., Ames, IA (United States)

    2001-01-01

    Laser-induced fluorescence detection is one of the most sensitive detection techniques and it has found enormous applications in various areas. The purpose of this research was to develop detection approaches based on laser-induced fluorescence detection in two different areas, heterogeneous catalysts screening and single cell study. First, the author introduced laser-induced imaging (LIFI) as a high-throughput screening technique for heterogeneous catalysts to explore the use of this high-throughput screening technique in discovery and study of various heterogeneous catalyst systems. This scheme is based on the fact that the creation or the destruction of chemical bonds alters the fluorescence properties of suitably designed molecules. By irradiating the region immediately above the catalytic surface with a laser, the fluorescence intensity of a selected product or reactant can be imaged by a charge-coupled device (CCD) camera to follow the catalytic activity as a function of time and space. By screening the catalytic activity of vanadium pentoxide catalysts in oxidation of naphthalene, they demonstrated LIFI has good detection performance and the spatial and temporal resolution needed for high-throughput screening of heterogeneous catalysts. The sample packing density can reach up to 250 x 250 subunits/cm2 for 40-μm wells. This experimental set-up also can screen solid catalysts via near infrared thermography detection. In the second part of this dissertation, the author used laser-induced native fluorescence coupled with capillary electrophoresis (LINF-CE) and microscope imaging to study the single cell degranulation. On the basis of good temporal correlation with events observed through an optical microscope, they have identified individual peaks in the fluorescence electropherograms as serotonin released from the granular core on contact with the surrounding fluid.

  15. Laser-Induced Fluorescence Detection in High-Throughput Screening of Heterogeneous Catalysts and Single Cells Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Su, Hui [Iowa State Univ., Ames, IA (United States)

    2001-01-01

    Laser-induced fluorescence detection is one of the most sensitive detection techniques and it has found enormous applications in various areas. The purpose of this research was to develop detection approaches based on laser-induced fluorescence detection in two different areas, heterogeneous catalysts screening and single cell study. First, we introduced laser-induced imaging (LIFI) as a high-throughput screening technique for heterogeneous catalysts to explore the use of this high-throughput screening technique in discovery and study of various heterogeneous catalyst systems. This scheme is based on the fact that the creation or the destruction of chemical bonds alters the fluorescence properties of suitably designed molecules. By irradiating the region immediately above the catalytic surface with a laser, the fluorescence intensity of a selected product or reactant can be imaged by a charge-coupled device (CCD) camera to follow the catalytic activity as a function of time and space. By screening the catalytic activity of vanadium pentoxide catalysts in oxidation of naphthalene, we demonstrated LIFI has good detection performance and the spatial and temporal resolution needed for high-throughput screening of heterogeneous catalysts. The sample packing density can reach up to 250 x 250 subunits/cm2 for 40-μm wells. This experimental set-up also can screen solid catalysts via near infrared thermography detection.

  16. BSA-AuNPs@Tb-AMP metal-organic frameworks for ratiometric fluorescence detection of DPA and Hg2.

    Science.gov (United States)

    Cai, Keying; Zeng, Mulan; Liu, Fenfen; Liu, Nan; Huang, Zhenzhong; Song, Yonghai; Wang, Li

    2017-11-01

    An easy and effective strategy for synthesizing a ratiometric fluorescent nanosensor has been demonstrated in this work. Novel fluorescent BSA-AuNPs@Tb-AMP (BSA, bovine serum albumin; AMP, adenosine 5'-monophosphate; AuNPs, Au nanoparticles) metal-organic framework (MOF) nanostructures were synthesized by encapsulating BSA-AuNPs into Tb-AMP MOFs for the detection of 2,6-pyridinedicarboxylic acid (DPA) and Hg 2+ . DPA could strongly co-ordinate with Tb 3+ to replace water molecules from the Tb 3+ center and accordingly enhanced the fluorescence of Tb-AMP MOFs. The fluorescence of BSA-AuNPs at 405 nm remained constant. While the fluorescence of BSA-AuNPs at 635 nm was quenched after Hg 2+ was added, the fluorescence of Tb-AMP MOFs remained constant. Accordingly, a ratiometric fluorescence nanosensor was constructed for detection of DPA and Hg 2+ . The ratiometric nanosensor exhibited good selectivity to DPA over other substances. The F 545 /F 405 linearly increased with increase of DPA concentration in the range of 50 nM to 10 μM with a detection limit as low as 17.4 nM. F 635 /F 405 increased linearly with increase of Hg 2+ concentration ranging from 50 nM to 1 μM with a detection limit as low as 20.9 nM. Additionally, the nanosensor could be successfully applied for the determination of DPA and Hg 2+ in running water. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Efficient fluorescence detection of protoporphyrin IX in metastatic lymph nodes of murine colorectal cancer stained with indigo carmine.

    Science.gov (United States)

    Matsuo, Hisataka; Harada, Yoshinori; Minamikawa, Takeo; Kato, Yoshiyuki; Murayama, Yasutoshi; Otsuji, Eigo; Takamatsu, Tetsuro; Tanaka, Hideo

    2017-09-01

    Protoporphyrin IX (PpIX), a biochemical converted from 5-aminolevulinc acid (5-ALA) in living cells, is useful for intraoperative fluorescent detection of cancer metastasis in lymph nodes (LNs). However, unknown is whether the fluorescence of PpIX can be detected in the LNs when they coexist with indigo carmine, a blue dye commonly used for identification of sentinel LNs during surgery. To address this issue, we sought to evaluate the diagnostic usefulness of PpIX fluorescence in the presence of indigo carmine in a mouse LN metastasis model of rectal cancer after administration of 5-ALA. Spectral analysis of pure chemicals revealed that the absorption spectrum of indigo carmine widely overlapped with the fluorescence spectrum of PpIX specifically at the peak of 632nm, a common emission wavelength for detecting PpIX, but not at the other peak of 700nm. Due to such spectral overlap, the PpIX fluorescence intensity was significantly attenuated by mixture with indigo carmine at 632nm, but not at 700nm. Accordingly, fluorescent measurements of the mouse metastatic LN revealed more intense presentation of PpIX at 700nm than at 632nm, indicating that the diagnostic usefulness is greater at 700nm than at 632nm for the indigo carmine-dyed LNs after administration of 5-ALA. From these observations, we propose that the fluorescence measurement is more efficient at 700nm than at 632nm for detection of PpIX in metastatic LNs stained with indigo carmine. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Detection and mapping of oil-contaminated soils by remote sensing of laser-induced fluorescence

    Science.gov (United States)

    Luedeker, Wilhelm; Guenther, Kurt P.; Dahn, Hans-Guenter

    1995-10-01

    The contamination of soil by aromatic mineral hydrocarbons (MHC) (e.g., gasoline, oil, etc.) has become a severe environmental problem because not only men, animals, and plants are threatened but also the water and air. With the unification of Germany a great number of suspected contaminated sites in the new countries were registered. An estimation of the German Federal Ministry of Environment (BMU) counts 180,000 areas contaminated with different pollutants, 55,000 are situated in the former GDR. On military settlements for example more than fifty percent of the chemicals are MHCs. Hence one can get an idea of the importance of soil pollution by hydrocarbons. Other zones contaminated due to carelessness or accidents are civil petrolstations, airports, refineries, pipelines, and traffic disasters. At the present time for most of these areas the contamination is assumed due to recent use. Due to the large extension of the problem an estimation and evaluation of the potential hazard for the environment is difficult and expensive to perform. In the case of an actual endangering the total area must be mapped in detail resulting in increasing costs for the owner. Nevertheless it is necessary to find reliable timesaving areal mapping and monitoring methods. One opportunity presented in this paper is the application of remote sensing by laser induced fluorescence from an airborne platform. It promises to fulfill these requirements in a sufficiently fast manner with very high spatial resolution. The access to the pollutant detection is the specific laser induced fluorescence emitted by the MHC (finger print). The present work shows the requirements for a helicopterborne lidar system for MHC mapping and how the detected signals are to be evaluated and interpreted.

  19. A rapid and cost-effective fluorescence detection in tube (FDIT method to analyze protein phosphorylation

    Directory of Open Access Journals (Sweden)

    Xiao Jin

    2016-11-01

    Full Text Available Abstract Background Protein phosphorylation is one of the most important post-translational modifications catalyzed by protein kinases in living organisms. The advance of genome sequencing provided the information of protein kinase families in many organisms, including both model and non-model plants. The development of proteomics technologies also enabled scientists to efficiently reveal a large number of protein phosphorylations of an organism. However, kinases and phosphorylation targets are still to be connected to illustrate the complicated network in life. Results Here we adapted Pro-Q® Diamond (Pro-Q® Diamond Phosphoprotein Gel Stain, a widely used phosphoprotein gel-staining fluorescence dye, to establish a rapid, economical and non-radioactive fluorescence detection in tube (FDIT method to analyze phosphorylated proteins. Taking advantages of high sensitivity and specificity of Pro-Q® diamond, the FDIT method is also demonstrated to be rapid and reliable, with a suitable linear range for in vitro protein phosphorylation. A significant and satisfactory protein kinase reaction was detected as fast as 15 min from Wheat Kinase START 1.1 (WKS1.1 on a thylakoid ascorbate peroxidase (tAPX, an established phosphorylation target in our earlier study. Conclusion The FDIT method saves up to 95% of the dye consumed in a gel staining method. The FDIT method is remarkably quick, highly reproducible, unambiguous and capable to be scaled up to dozens of samples. The FDIT method could serve as a simple and sensitive alternative procedure to determine protein kinase reactions with zero radiation exposure, as a supplementation to other widely used radioactive and in-gel assays.

  20. A simple, fast and low-cost turn-on fluorescence method for dopamine detection using in situ reaction

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiulan [School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003 (China); Zhu, Yonggang [Microfluidics and Fluid Dynamics Laboratory, CSIRO Manufacturing, Private Bag 10, Clayton South, Victoria, 3168 (Australia); Li, Xie [School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003 (China); Guo, Xuhong [School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003 (China); State Key Laboratory of Chemical Engineering, East China University of Science and Technology, Shanghai, 200237 (China); Zhang, Bo [Key Laboratory of Xinjiang Phytomedicine Resources of Ministry of Education, School of Pharmacy, Shihezi University, Shihezi, 832000 (China); Jia, Xin, E-mail: jiaxin@shzu.edu.cn [School of Chemistry and Chemical Engineering/Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Bingtuan, Key Laboratory of Materials-Oriented Chemical Engineering of Xinjiang Uygur Autonomous Region, Engineering Research Center of Materials-Oriented Chemical Engineering of Xinjiang Bingtuan, Shihezi University, Shihezi, 832003 (China); and others

    2016-11-09

    A simple, fast and low-cost method for dopamine (DA) detection based on turn-on fluorescence using resorcinol is developed. The rapid reaction between resorcinol and DA allows the detection to be performed within 5 min, and the reaction product (azamonardine) with high quantum yield generates strong fluorescence signal for sensitive optical detection. The detection exhibits a high sensitivity to DA with a wide linear range of 10 nM–20 μM and the limit of detection is estimated to be 1.8 nM (S/N = 3). This approach has been successfully applied to determine DA concentrations in human urine samples with satisfactory quantitative recovery of 97.84%–103.50%, which shows great potential in clinical diagnosis. - Highlights: • A turn-on fluorescence technique is developed for dopamine detection by using one-step selective reaction between resorcinol and dopamine. • The limit of detection is 1.8 nM (S/N = 3). • This detection could be completed within 5 min. • The method has been demonstrated to successfully detect dopamine in human urine samples with high recovery ratio of 97.84%–103.50%.

  1. A simple, fast and low-cost turn-on fluorescence method for dopamine detection using in situ reaction

    International Nuclear Information System (INIS)

    Zhang, Xiulan; Zhu, Yonggang; Li, Xie; Guo, Xuhong; Zhang, Bo; Jia, Xin

    2016-01-01

    A simple, fast and low-cost method for dopamine (DA) detection based on turn-on fluorescence using resorcinol is developed. The rapid reaction between resorcinol and DA allows the detection to be performed within 5 min, and the reaction product (azamonardine) with high quantum yield generates strong fluorescence signal for sensitive optical detection. The detection exhibits a high sensitivity to DA with a wide linear range of 10 nM–20 μM and the limit of detection is estimated to be 1.8 nM (S/N = 3). This approach has been successfully applied to determine DA concentrations in human urine samples with satisfactory quantitative recovery of 97.84%–103.50%, which shows great potential in clinical diagnosis. - Highlights: • A turn-on fluorescence technique is developed for dopamine detection by using one-step selective reaction between resorcinol and dopamine. • The limit of detection is 1.8 nM (S/N = 3). • This detection could be completed within 5 min. • The method has been demonstrated to successfully detect dopamine in human urine samples with high recovery ratio of 97.84%–103.50%.

  2. The Synthesis of a Coumarin Carbohydrazide Dinuclear Copper Complex Based Fluorescence Probe and Its Detection of Thiols.

    Directory of Open Access Journals (Sweden)

    Guangjie He

    Full Text Available Small-molecule thiols, such as cysteine (CYS and glutathione (GSH, are essential for maintaining the cellular redox environment and play important roles in regulating various cellular physiological functions. A fluorescence probe (compound 1-Cu2+ for thiols based on coumarin carbohydrazide dinuclear copper complex was developed. Compound 1 was synthesized from the reaction of 7-(diethylamino-2-oxo-2H-chromene-3-carbohydrazide with 4-tert-butyl-2,6- diformylphenol. Accordingly, the copper complex (compound 1-Cu2+ was prepared by mixing compound 1 with 2 equivalents copper ions. Compound 1 had strong fluorescence while compound 1-Cu2+ hardly possessed fluorescence owing to the quenching nature of paramagnetism Cu2+ to the fluorescence molecule excited state. However, the fluorescence intensity of compound 1-Cu2+ was increased dramatically after the addition of thiol-containing amino acids, but not the other non-sulfhydryl amino acids. UV-vis absorption and fluorescence spectra indicated that compound 1-Cu2+ had good selectivity and sensitivity for thiols such as glutathione in CH3CN:H2O (3:2, v/v PBS solution. The fluorescence imaging experiments implied that compound 1-Cu2+ has potential application in thiol-containing amino acids detection in living cells.

  3. Automated detection of breast cancer in resected specimens with fluorescence lifetime imaging

    Science.gov (United States)

    Phipps, Jennifer E.; Gorpas, Dimitris; Unger, Jakob; Darrow, Morgan; Bold, Richard J.; Marcu, Laura

    2018-01-01

    Re-excision rates for breast cancer lumpectomy procedures are currently nearly 25% due to surgeons relying on inaccurate or incomplete methods of evaluating specimen margins. The objective of this study was to determine if cancer could be automatically detected in breast specimens from mastectomy and lumpectomy procedures by a classification algorithm that incorporated parameters derived from fluorescence lifetime imaging (FLIm). This study generated a database of co-registered histologic sections and FLIm data from breast cancer specimens (N  =  20) and a support vector machine (SVM) classification algorithm able to automatically detect cancerous, fibrous, and adipose breast tissue. Classification accuracies were greater than 97% for automated detection of cancerous, fibrous, and adipose tissue from breast cancer specimens. The classification worked equally well for specimens scanned by hand or with a mechanical stage, demonstrating that the system could be used during surgery or on excised specimens. The ability of this technique to simply discriminate between cancerous and normal breast tissue, in particular to distinguish fibrous breast tissue from tumor, which is notoriously challenging for optical techniques, leads to the conclusion that FLIm has great potential to assess breast cancer margins. Identification of positive margins before waiting for complete histologic analysis could significantly reduce breast cancer re-excision rates.

  4. Axion dark matter detection by laser induced fluorescence in rare-earth doped materials.

    Science.gov (United States)

    Braggio, Caterina; Carugno, Giovanni; Chiossi, Federico; Lieto, Alberto Di; Guarise, Marco; Maddaloni, Pasquale; Ortolan, Antonello; Ruoso, Giuseppe; Santamaria, Luigi; Tasseva, Jordanka; Tonelli, Mauro

    2017-11-09

    We present a detection scheme to search for QCD axion dark matter, that is based on a direct interaction between axions and electrons explicitly predicted by DFSZ axion models. The local axion dark matter field shall drive transitions between Zeeman-split atomic levels separated by the axion rest mass energy m a c 2 . Axion-related excitations are then detected with an upconversion scheme involving a pump laser that converts the absorbed axion energy (~hundreds of μeV) to visible or infrared photons, where single photon detection is an established technique. The proposed scheme involves rare-earth ions doped into solid-state crystalline materials, and the optical transitions take place between energy levels of 4f N electron configuration. Beyond discussing theoretical aspects and requirements to achieve a cosmologically relevant sensitivity, especially in terms of spectroscopic material properties, we experimentally investigate backgrounds due to the pump laser at temperatures in the range 1.9 - 4.2 K. Our results rule out excitation of the upper Zeeman component of the ground state by laser-related heating effects, and are of some help in optimizing activated material parameters to suppress the multiphonon-assisted Stokes fluorescence.

  5. Characterization and optimization of a red-shifted fluorescence polarization ADP detection assay.

    Science.gov (United States)

    Kleman-Leyer, Karen M; Klink, Tony A; Kopp, Andrew L; Westermeyer, Thane A; Koeff, Mark D; Larson, Brad R; Worzella, Tracy J; Pinchard, Cori A; van de Kar, Sebastianus A T; Zaman, Guido J R; Hornberg, Jorrit J; Lowery, Robert G

    2009-02-01

    ATP depletion and ADP formation are generic detection methods used for the identification of kinase and other ATP-utilizing enzyme inhibitors in high-throughput screening campaigns. However, the most widely used nucleotide detection approaches require high ATP consumption rates or involve the use of coupling enzymes, which can complicate the selection of lead compounds. As an alternative, we have developed the Transcreener (BellBrook Labs, Madison, WI) platform, which relies on the direct immunodetection of nucleotides. Here we describe the development of antibodies with >100-fold selectivity for ADP versus ATP, which enable robust detection of initial velocity rates (Z' > 0.7 at 10% substrate consumption) at ATP concentrations ranging from 0.1 microM to 1,000 microM in a competitive fluorescence polarization (FP) immunoassay. Competitive binding experiments indicate similar affinities for other nucleotide diphosphates, including 2' -deoxy ADP, GDP, and UDP. The antibody-tracer complex and the red-shifted, ratiometric FP signal are stable for at least 24 h at room temperature, providing suitable conditions for high-throughput screening. A method for calculating a kinase ATP Km with this FP immunoassay is also presented. The Transcreener ADP assay provides a simple, generic assay platform for inhibitor screening and selectivity profiling that can be used for any ADP-generating enzyme.

  6. Evaluation of a miniature microscope objective designed for fluorescence array microscopy detection of Mycobacterium tuberculosis.

    Science.gov (United States)

    McCall, Brian; Olsen, Randall J; Nelles, Nicole J; Williams, Dawn L; Jackson, Kevin; Richards-Kortum, Rebecca; Graviss, Edward A; Tkaczyk, Tomasz S

    2014-03-01

    A prototype miniature objective that was designed for a point-of-care diagnostic array microscope for detection of Mycobacterium tuberculosis and previously fabricated and presented in a proof of concept is evaluated for its effectiveness in detecting acid-fast bacteria. To evaluate the ability of the microscope to resolve submicron features and details in the image of acid-fast microorganisms stained with a fluorescent dye, and to evaluate the accuracy of clinical diagnoses made with digital images acquired with the objective. The lens prescription data for the microscope design are presented. A test platform is built by combining parts of a standard microscope, a prototype objective, and a digital single-lens reflex camera. Counts of acid-fast bacteria made with the prototype objective are compared to counts obtained with a standard microscope over matched fields of view. Two sets of 20 smears, positive and negative, are diagnosed by 2 pathologists as sputum smear positive or sputum smear negative, using both a standard clinical microscope and the prototype objective under evaluation. The results are compared to a reference diagnosis of the same sample. More bacteria are counted in matched fields of view in digital images taken with the prototype objective than with the standard clinical microscope. All diagnostic results are found to be highly concordant. An array microscope built with this miniature lens design will be able to detect M tuberculosis with high sensitivity and specificity.

  7. Ultrasensitive Quantum Dot Fluorescence quenching Assay for Selective Detection of Mercury Ions in Drinking Water

    Science.gov (United States)

    Ke, Jun; Li, Xinyong; Zhao, Qidong; Hou, Yang; Chen, Junhong

    2014-07-01

    Mercury is one of the most acutely toxic substances at trace level to human health and living thing. Developing a rapid, cheap and water soluble metal sensor for detecting mercury ions at ppb level remains a challenge. Herein, a metal sensor consisting of MPA coated Mn doped ZnSe/ZnS colloidal nanoparticles was utilized to ultrasensitively and selectively detect Hg2+ ions with a low detection limit (0.1 nM) over a dynamic range from 0 to 20 nM. According to strong interaction between thiol(s) and mercury ions, mercaptopropionic acid (MPA) was used as a highly unique acceptor for mercury ions in the as-obtained ultrasensitive sensor. In the presence of mercury ions, colloidal nanoparticles rapidly agglomerated due to changes of surface chemical properties, which results in severe quenching of fluorescent intensity. Meanwhile, we find that the original ligands are separated from the surface of colloidal nanoparticles involving strongly chelation between mercury ion and thiol(s) proved by controlled IR analysis. The result shows that the QD-based metal ions sensor possesses satisfactory precision, high sensitivity and selectivity, and could be applied for the quantification analysis of real samples.

  8. Construction of genetically engineered bacteria that degrades organophosphorus pesticide residues and can be easily detected by the fluorescence.

    Science.gov (United States)

    Li, Qin; Wang, Pan; Chen, Rui; Li, Wei; Wu, Yi-Jun

    2014-01-01

    Organophosphorus compounds (OPs) are widely used in agriculture and industry and there is increased concern about their toxicological effects in the environment. Bioremediation can offer an efficient and cost-effective option for the removal of OPs. Herein, we describe the construction of a genetically engineered microorganism (GEM) that can degrade OPs and be directly detected and monitored in the environment using an enhanced green fluorescent protein (EGFP) fusion strategy. The coding regions of EGFP, a reporter protein that can fluoresce by itself, and organophosphorus hydrolase (OPH), which has a broad substrate specificity and is able to hydrolyse a number of organophosphorus pesticides, were cloned into the expression vector pET-28b. The fusion protein of EGFP-OPH was expressed in E. coli BL21 (DE3) and the protein expression reached the highest level at 11 h after isopropyl beta-D-thiogalactopyranoside induction. The fluorescence of the GEM was detected by fluorescence spectrophotometry and microscopy, and its ability to degrade OPs was determined by OPH activity assay. Those GEM that express the fusion protein (EGFP and OPH) exhibited strong fluorescence intensity and also potent hydrolase activity, which could be used to degrade organophosphorus pesticide residues in the environment and can also be directly monitored by fluorescence.

  9. On the influence of the instillation time on the results of HAL (Hexvix) fluorescence detection of superficial bladder cancer

    Science.gov (United States)

    Jichlinski, Patrice; Aymon, Daniela; Wagnieres, Georges A.; Marti, Alexandre; Lange, Norbert; Guillou, Louis; Leisinger, Hans-Juerg; van den Bergh, Hubert

    2003-10-01

    Hexyl aminolevulinate (HAL) fluorescence cystoscopy is being investigated as a new diagnostic tool for the detection of flat urothelial malignancies in bladder cancers. However, the influence of the bladder instillation time on the performance of this detection modality has not been addressed up to now. We report our initial experience comparing different instillation schedules of HAL cystoscopy in the diagnosis of superficial bladder cancer. A total of 718 fluorescent positive (433) and fluorescence negative (285) biopsies have been taken in the bladder of 143 patients using the Storz D-light fluorescence imaging system (Karl Storz, Tuttlingen, Germany) which allows both white and blue light (380-450 nm) bladder wall inspection. Following hospitalisation, 50 ml of HAL (8mM) phosphate buffer solution was instilled into the bladder of patients during one hour (1 hour protocol involving 57 patients), or during two hours followed by a two hours resting time after removal of the solution (2+2 hours protocol involving 86 patients). Both instillation subgroups were homogeneous in terms of proportion of high risk disease, previous BCG treatment and/or recurrent disease. This study indicates that the instillation duration does not influence the results of HAL (Hexvix) fluorescence cystoscopy in our conditions. Compared to the standard use of ALA, HAL (Hexvix) fluorescence cystoscopy allows a significant reduction of the instillation time (to less than one hour) without prejudicing the efficacy of the method, what represents a real advantage in daily clinical practice.

  10. A coumarin based Schiff base probe for selective fluorescence detection of Al3 + and its application in live cell imaging

    Science.gov (United States)

    Sen, Bhaskar; Sheet, Sanjoy Kumar; Thounaojam, Romita; Jamatia, Ramen; Pal, Amarta Kumar; Aguan, Kripamoy; Khatua, Snehadrinarayan

    2017-02-01

    A new coumarin based Schiff base compound, CSB-1 has been synthesized to detect metal ion based on the chelation enhanced fluorescence (CHEF). The cation binding properties of CSB-1 was thoroughly examined in UV-vis and fluorescence spectroscopy. In fluorescence spectroscopy the compound showed high selectivity toward Al3 + ion and the Al3 + can be quantified in mixed aqueous buffer solution (MeOH: 0.01 M HEPES Buffer; 9:1; v/v) at pH 7.4 as well as in BSA media. The fluorescence intensity of CSB-1 was enhanced by 24 fold after addition of only five equivalents of Al3 +. The fluorescence titration of CSB-1 with Al3 + in mixed aqueous buffer afforded a binding constant, Ka = (1.06 ± 0.2) × 104 M- 1. The colour change from light yellow to colourless and the appearance of blue fluorescence, which can be observed by the naked eye, provides a real-time method for Al3 + sensing. Further the live cell imaging study indicated that the detection of intracellular Al3 + ions are also readily possible in living cell.

  11. A G-quadruplex based fluorescent oligonucleotide turn-on probe towards iodides detection in real samples.

    Science.gov (United States)

    Li, Qian; Li, Shuaihua; Chen, Xiu; Bian, Liujiao

    2017-09-01

    A basket-type G-quadruplex (GQ) fluorescent oligonucleotide (OND) probe is designed to detect iodides dependent on thymine-Hg(II)-thymine (T-Hg(II)-T) base pairs and the intrinsic fluorescence quenching capacity of GQ. In the presence of Hg(II) ions (Hg 2+ ), the two hexachloro-fluorescein-labeled ONDs form a hairpin structure and the fluorophores are dragged close to the GQ, leading to fluorescence quenching of the probe due to photoinduced electron transfer. Upon addition of iodide anions, Hg 2+ are extracted from T-Hg(II)-T complexes which attributes to the stronger binding with iodide anions, resulting in the fluorescence recovery. Through performing the fluorescence quenching and recovery processes, this probe developed a fluorescence turn-on sensor for iodide anions determination over a linear range of 20-200nmol/L with a limit of detection of 5nmol/L. The practical use of the turn-on technology was demonstrated by its application in determination of iodides in water, food, pharmaceutical products and biological samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. A "turn-on" fluorescent sensor for ozone detection in ambient air using protein-directed gold nanoclusters.

    Science.gov (United States)

    Wu, Di; Qi, Wenjing; Liu, Chun; Zhang, Qing

    2017-04-01

    A "turn-on" fluorescent sensor for ozone using bovine serum albumin-directed gold nanoclusters (BSA-Au NCs) via energy transfer was developed. The spectral overlap of fluorescent spectrum of BSA-Au NCs with absorption spectrum of indigo carmine (IDS) was utilized. Ozone cleaves C = C bond of IDS and suppresses energy transfer from BSA-Au NCs to IDS. Therefore, this proposed fluorescent sensor is a "turn-on" detection motif. It is the first application of fluorescent nanoclusters in sensitively detecting ozone from 0.2 to 12 μM with the limit of detection of 35 nM (the volume of 500 μL, 1.68 ppb). The proposed fluorescent sensor for ozone is more sensitive and faster (within 2 min) than most methods and is with good selectivity for ozone detection against other reactive oxygen species, reactive nitrogen, or metallic ions. Besides, the proposed method is also utlized in ozone detection in ambient air by monitoring 1 h (60 min) in Qijiang district in Chongqing city. The average of concentration of ozone in ambient air ranges from 44.97 to 52.85 μg/m 3 . The results are compared with the automatic monitoring data provided by Qijiang Environmental Monitoring Station and the relative deviations range, respectively, from 2.1 to 5.6%, which suggests that it is a promising fluorescent sensor for ozone in ambient air. This study not only develops a new model of energy transfer motif using BSA-Au NCs as donor and IDS as acceptor but also expands the application of BSA-Au NCs in environmental science. Graphical abstract A "turn-on" fluorescent sensor for ozone detection using bovine serum albumin-directed gold nanoclusters (BSA-Au NCs) via energy transfer is developed. It is the first time to utilize spectral overlap of fluorescent spectrum of BSA-Au NCs with absorption spectrum of indigo carmine and to achieve fast, sensitive, and selective ozone detection with a limit of detection of down to 35 nM (the volume of 500 μL, 1.68 ppb).

  13. Development of a fluorescent antibody method for the detection of Enterococcus faecium and its potential for coastal aquatic environment monitoring.

    Science.gov (United States)

    Caruso, Gabriella; Monticelli, L S; Caruso, R; Bergamasco, A

    2008-02-01

    A direct, microscopic fluorescent antibody method was developed to detect the occurrence of Enterococcus faecium in coastal aquatic environments and was compared with the conventional membrane filtering method. The "in situ" application of the antibody-based protocol in the analysis of water samples collected from coastal polyhaline habitats demonstrated good sensitivity and ease of implementation. Data obtained with the microscopic technique were in agreement with those obtained from culture counts. The fluorescent antibody method proved to be a rapid and reliable technique for the detection of E. faecium. The advantages and limitations intrinsic to the method are discussed, highlighting the potential of this new technique for monitoring coastal aquatic environments.

  14. Electrostatic-assembly-driven formation of supramolecular rhombus microparticles and their application for fluorescent nucleic acid detection.

    Directory of Open Access Journals (Sweden)

    Hailong Li

    Full Text Available In this paper, we report on the large-scale formation of supramolecular rhombus microparticles (SRMs driven by electrostatic assembly, carried out by direct mixing of an aqueous HAuCl(4 solution and an ethanol solution of 4,4'-bipyridine at room temperature. We further demonstrate their use as an effective fluorescent sensing platform for nucleic acid detection with a high selectivity down to single-base mismatch. The general concept used in this approach is based on adsorption of the fluorescently labeled single-stranded DNA (ssDNA probe by SRM, which is accompanied by substantial fluorescence quenching. In the following assay, specific hybridization with its target to form double-stranded DNA (dsDNA results in desorption of ssDNA from SRM surface and subsequent fluorescence recovery.

  15. Fluorescent signaling based on sulfoxide profluorophores: application to the visual detection of the explosive TATP.

    Science.gov (United States)

    Malashikhin, Sergey; Finney, Nathaniel S

    2008-10-01

    The first visual fluorescence-based assay for the peroxide explosive triacetone triperoxide (TATP) is described. The assay is based on a conceptually new fluorescence signaling mechanism, in which nonemissive pyrenyl sulfoxide profluorophores are oxidized to visibly emissive pyrenyl sulfones. Although not without limitations, these first-generation fluorescent probes can provide a visual response to ca. 100 nmol of TATP. In addition, the success of this assay suggests the potential for broader application of aryl sulfoxides in fluorescent chemosensing.

  16. Determination of ultra trace arsenic species in water samples by hydride generation atomic absorption spectrometry after cloud point extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ulusoy, Halil Ibrahim, E-mail: hiulusoy@yahoo.com [University of Cumhuriyet, Faculty of Science, Department of Chemistry, TR-58140, Sivas (Turkey); Akcay, Mehmet; Ulusoy, Songuel; Guerkan, Ramazan [University of Cumhuriyet, Faculty of Science, Department of Chemistry, TR-58140, Sivas (Turkey)

    2011-10-10

    Graphical abstract: The possible complex formation mechanism for ultra-trace As determination. Highlights: {yields} CPE/HGAAS system for arsenic determination and speciation in real samples has been applied first time until now. {yields} The proposed method has the lowest detection limit when compared with those of similar CPE studies present in literature. {yields} The linear range of the method is highly wide and suitable for its application to real samples. - Abstract: Cloud point extraction (CPE) methodology has successfully been employed for the preconcentration of ultra-trace arsenic species in aqueous samples prior to hydride generation atomic absorption spectrometry (HGAAS). As(III) has formed an ion-pairing complex with Pyronine B in presence of sodium dodecyl sulfate (SDS) at pH 10.0 and extracted into the non-ionic surfactant, polyethylene glycol tert-octylphenyl ether (Triton X-114). After phase separation, the surfactant-rich phase was diluted with 2 mL of 1 M HCl and 0.5 mL of 3.0% (w/v) Antifoam A. Under the optimized conditions, a preconcentration factor of 60 and a detection limit of 0.008 {mu}g L{sup -1} with a correlation coefficient of 0.9918 was obtained with a calibration curve in the range of 0.03-4.00 {mu}g L{sup -1}. The proposed preconcentration procedure was successfully applied to the determination of As(III) ions in certified standard water samples (TMDA-53.3 and NIST 1643e, a low level fortified standard for trace elements) and some real samples including natural drinking water and tap water samples.

  17. The microbe capture experiment in space: Fluorescence microscopic detection of microbes captured by aerogel

    Science.gov (United States)

    Sugino, Tomohiro; Yokobori, Shin-Ichi; Yang, Yinjie; Kawaguchi, Yuko; Okudaira, Kyoko; Tabata, Makoto; Kawai, Hideyuki; Hasegawa, Sunao; Yamagishi, Akihiko

    Microbes have been collected at the altitude up to about 70 km in the sampling experiment done by several groups[1]. We have also collected high altitude microbes, by using an airplane and balloons[2][3][4][5]. We collected new deinococcal strain (Deinococcus aetherius and Deinococ-cus aerius) and several strains of spore-forming bacilli from stratosphere[2][4][5]. However, microbe sampling in space has never been reported. On the other hand, "Panspermia" hy-pothesis, where terrestrial life is originated from outside of Earth, has been proposed[6][7][8][9]. Recent report suggesting existence of the possible microbe fossils in the meteorite of Mars origin opened the serious debate on the possibility of migration of life embedded in meteorites (and cosmic dusts)[10][11]. If we were able to find terrestrial microbes in space, it would suggest that the terrestrial life can travel between astronomical bodies. We proposed a mission "Tanpopo: Astrobiology Exposure and Micrometeoroid Capture Experiments" to examine possible inter-planetary migration of microbes, organic compounds and meteoroids on Japan Experimental Module of the International Space Station (ISS)[12]. Two of six sub themes in this mission are directly related to interplanetary migration of microbes. One is the direct capturing experi-ment of microbes (probably within the particles such as clay) in space by the exposed ultra-low density aerogel. Another is the exposure experiment to examine survivability of the microbes in harsh space environment. They will tell us the possibility of interplanetary migration of microbes (life) from Earth to outside of Earth (or vise versa). In this report, we will report whether aerogel that have been used for the collection of space debris and cosmic dusts can be used for microbe sampling in space. We will discuss how captured particles by aerogel can be detected with DNA-specific fluorescent dye, and how to distinguish microbes from other mate-rials (i.e. aerogel and

  18. Optical detection of λ-cyhalothrin by core-shell fluorescent molecularly imprinted polymers in Chinese spirits.

    Science.gov (United States)

    Wang, Jixiang; Gao, Lin; Han, Donglai; Pan, Jianming; Qiu, Hao; Li, Hongji; Wei, Xiao; Dai, Jiangdong; Yang, Jinghai; Yao, Hui; Yan, Yongsheng

    2015-03-11

    In this study, fluorescent molecularly imprinted polymers (FMIPs), which were for the selective recognition and fluorescence detection of λ-cyhalothrin (LC), were synthesized via fluorescein 5(6)-isothiocyanate (FITC) and 3-aminopropyltriethoxysilane (APTS)/SiO2 particles. The SiO2@FITC-APTS@MIPs were characterized by Fourier transform infrared (FT-IR), UV-vis spectrophotometer (UV-vis), fluorescence spectrophotometer, thermogravimetric analysis (TGA), confocal laser scanning microscope (CLSM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). The as-synthesized SiO2@FITC-APTS@MIPs with an imprinted polymer film (thickness was about 100 nm) was demonstrated to be spherically shaped and had good monodispersity, high fluorescence intensity, and good selective recognition. Using fluorescence quenching as the detection tool, the largest fluorescence quenching efficiency (F0/F - 1) of SiO2@FITC-APTS@MIPs is close to 2.5 when the concentration of the LC is 1.0 μM L(-1). In addition, a linear relationship (F0/F - 1= 0.0162C + 0.0272) could be obtained covering a wide concentration range of 0-60 nM L(-1) with a correlation coefficient of 0.9968 described by the Stern-Volmer equation. Moreover, the limit of detection (LOD) of the SiO2@FITC-APTS@MIPs was 9.17 nM L(-1). The experiment results of practical detection revealed that the SiO2@FITC-APTS@MIPs as an attractive recognition element was satisfactory for the determination of LC in Chinese spirits. Therefore, this study demonstrated the potential of SiO2@FITC-APTS@MIPs for the recognition and detection of LC in food.

  19. Detection of trace tetracycline in fish via synchronous fluorescence quenching with carbon quantum dots coated with molecularly imprinted silica

    Science.gov (United States)

    Yang, Ji; Lin, Zheng-Zhong; Nur, A.-Zha; Lu, Yan; Wu, Ming-Hui; Zeng, Jun; Chen, Xiao-Mei; Huang, Zhi-Yong

    2018-02-01

    A novel fluorescence-based sensor combining synchronous fluorescence spectroscopy (SFS) with molecularly imprinted polymers (MIPs) was fabricated with reverse microemulsion method. Tetracycline (TC), (3-aminopropyl) triethoxysilane (APTES), tetraethyl orthosilicate (TEOS) and carbon quantum dots (CDs) were used as template, functional monomer, cross-linker and signal sources respectively in the probe preparation. A synchronous fluorescence emission (λem) at 355 nm was observed for the prepared MIP-coated CDs (MIP@CDs) particles when the wavelength interval (Δλ) was set as 70 nm, and the synchronous fluorescence intensity could be rapidly and efficiently quenched by TC based on inner filter effect (IFE). The quenching efficiencies of synchronous fluorescence intensity was linearly fitted with tetracycline (TC) concentrations ranging from 0.1 to 50 μmol L- 1 with a detection limit (DL) of 9 nmol L- 1 (3σ, n = 9). The MIP@CDs was used as a probe to detect TC in fish samples with the recoveries ranging from 98.4% to 103.1% and the relative standard deviation less than 6.0%. The results illustrated that the as-prepared MIP@CDs could be applied to the detection of trace TC in fish samples with rapidity, high sensitivity and accuracy.

  20. "Turn-on" fluorescence detection of lead ions based on accelerated leaching of gold nanoparticles on the surface of graphene.

    Science.gov (United States)

    Fu, Xiuli; Lou, Tingting; Chen, Zhaopeng; Lin, Meng; Feng, Weiwei; Chen, Lingxin

    2012-02-01

    A novel platform for effective "turn-on" fluorescence sensing of lead ions (Pb(2+)) in aqueous solution was developed based on gold nanoparticle (AuNP)-functionalized graphene. The AuNP-functionalized graphene exhibited minimal background fluorescence because of the extraordinarily high quenching ability of AuNPs. Interestingly, the AuNP-functionalized graphene underwent fluorescence restoration as well as significant enhancement upon adding Pb(2+), which was attributed to the fact that Pb(2+) could accelerate the leaching rate of the AuNPs on graphene surfaces in the presence of both thiosulfate (S(2)O(3)(2-)) and 2-mercaptoethanol (2-ME). Consequently, this could be utilized as the basis for selective detection of Pb(2+). With the optimum conditions chosen, the relative fluorescence intensity showed good linearity versus logarithm concentration of Pb(2+) in the range of 50-1000 nM (R = 0.9982), and a detection limit of 10 nM. High selectivity over common coexistent metal ions was also demonstrated. The practical application had been carried out for determination of Pb(2+) in tap water and mineral water samples. The Pb(2+)-specific "turn-on" fluorescence sensor, based on Pb(2+) accelerated leaching of AuNPs on the surface of graphene, provided new opportunities for highly sensitive and selective Pb(2+) detection in aqueous media.

  1. Performance of laser fluorescence devices and visual examination for the detection of occlusal caries in permanent molars

    Science.gov (United States)

    Rechmann, Peter; Charland, Daniel; Rechmann, Beate M. T.; Featherstone, John D. B.

    2012-03-01

    The aim of this study was to evaluate the diagnostic capabilities of a laser fluorescence tool DIAGNOdent (KaVo, Biberach, Germany) and two light-emitting diode fluorescence tools--Spectra Caries Detection Aid (AIR TECHNIQUES, Melville, NY), and SOPROLIFE light-induced fluorescence evaluator in daylight and blue florescence mode (SOPRO, ACTEON Group, La Ciotat, France)--in comparison to the caries detection and assessment system (ICDAS-II) in detection of caries lesions. In 100 subjects (age 23.4+/-10.6 years), 433 posterior permanent unrestored teeth were examined. On the occlusal surfaces, up to 1066 data points for each assessment method were available for statistical evaluation, including 1034 ICDAS scores (intra-examiner kappa=0.884). For the SOPROLIFE tool, a new caries-scoring system was developed. Per assessment tool each average score for one given ICDAS code was significantly different from the one for another ICDAS code. Normalized data linear regression revealed that both SOPROLIFE assessment tools allowed for best caries score discrimination followed by DIAGNOdent and Spectra Caries Detection Aid. The area under the receiver operating characteristics curve calculations showed the same grading sequence when cutoff point ICDAS codes 0-1-2 were grouped together. Sensitivity and specificity values at the same cutoff were calculated (DIAGNOdent 87/66, Spectra Caries Detection Aid 93/37, SOPROLIFE 93/63, SOPROLIFE blue fluorescence 95/55.)

  2. Sensitive detection of mercury and copper ions by fluorescent DNA/Ag nanoclusters in guanine-rich DNA hybridization.

    Science.gov (United States)

    Peng, Jun; Ling, Jian; Zhang, Xiu-Qing; Bai, Hui-Ping; Zheng, Liyan; Cao, Qiu-E; Ding, Zhong-Tao

    2015-02-25

    In this work, we designed a new fluorescent oligonucleotides-stabilized silver nanoclusters (DNA/AgNCs) probe for sensitive detection of mercury and copper ions. This probe contains two tailored DNA sequence. One is a signal probe contains a cytosine-rich sequence template for AgNCs synthesis and link sequence at both ends. The other is a guanine-rich sequence for signal enhancement and link sequence complementary to the link sequence of the signal probe. After hybridization, the fluorescence of hybridized double-strand DNA/AgNCs is 200-fold enhanced based on the fluorescence enhancement effect of DNA/AgNCs in proximity of guanine-rich DNA sequence. The double-strand DNA/AgNCs probe is brighter and stable than that of single-strand DNA/AgNCs, and more importantly, can be used as novel fluorescent probes for detecting mercury and copper ions. Mercury and copper ions in the range of 6.0-160.0 and 6-240 nM, can be linearly detected with the detection limits of 2.1 and 3.4 nM, respectively. Our results indicated that the analytical parameters of the method for mercury and copper ions detection are much better than which using a single-strand DNA/AgNCs. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Comparison of molecular imprinted particles prepared using precipitation polymerization in water and chloroform for fluorescent detection of nitroaromatics

    International Nuclear Information System (INIS)

    Stringer, R. Cody; Gangopadhyay, Shubhra; Grant, Sheila A.

    2011-01-01

    Highlights: → Imprinted polymers prepared using precipitation polymerization. → Comparison of chloroform and water as polymerization solvent. → Imprinted polymer doped with quantum dots for fluorescent sensor. → Fluorescent imprinted polymer used to detect nitroaromatic explosives. → Chloroform is ideal solvent for molecular imprinting of nitroaromatics. - Abstract: A comparative study was conducted to study the effects that two different polymerization solvents would have on the properties of imprinted polymer microparticles prepared using precipitation polymerization. Microparticles prepared in chloroform, which previous results indicated was the optimal solvent for molecular imprinting of nitroaromatic explosive compounds, were compared to water, which was hypothesized to decrease water swelling of the polymer and allow enhanced rebinding of aqueous template. The microparticles were characterized and were integrated into a fluorescence sensing mechanism for detection of nitroaromatic explosive compounds. The performance of the sensing mechanisms was compared to illustrate which polymerization solvent produced optimal imprinted polymer microparticles for detection of nitroaromatic molecules. Results indicated that the structures of microparticles synthesized in chloroform versus water varied greatly. Sensor performance studies showed that the microparticles prepared in chloroform had greater imprinting efficiency and higher template rebinding than those prepared in water. For detection of 2,4,6-trinitrotoluene, the chloroform-based fluorescent microparticles achieved a lower limit of detection of 0.1 μM, as compared to 100 μM for the water-based fluorescent microparticles. Detection limits for 2,4-dinitrotoluene, as well as time response studies, also demonstrated that the chloroform-based particles are more effective for detection of nitroaromatic compounds than water-based particles. These results illustrate that the enhanced chemical properties of

  4. Green synthesis of fluorescence carbon nanoparticles from yum and application in sensitive and selective detection of ATP.

    Science.gov (United States)

    Zhan, Zixuan; Cai, Jiao; Wang, Qi; Su, Yingying; Zhang, Lichun; Lv, Yi

    2016-05-01

    Fluorescent carbon nanoparticles (CPs), a fascinating class of recently discovered nanocarbons, have been widely known as some of the most promising sensing probes in biological or chemical analysis. In this study, we demonstrate a green synthetic methodology for generating water-soluble CPs with a quantum yield of approximately 24% via a simple heating process using yum mucilage as a carbon source. The prepared carbon nanoparticles with an ~10 nm size possessed excellent fluorescence properties, and the fluorescence of the CPs was strongly quenched by Fe(3+), and recovered by adenosine triphosphate (ATP), thus, an 'off' and 'on' system can be easily established. This 'CPs-Fe(3+)-ATP' strategy was sensitive and selective at detecting ATP with the linear range of 0.5 µmol L(-1) to 50 µmol L(-1) and with a detection limit of 0.48 µmol L(-1). Copyright © 2015 John Wiley & Sons, Ltd.

  5. A novel NBD-based fluorescent turn-on probe for the detection of cysteine and homocysteine in living cells

    Science.gov (United States)

    Wang, Jiamin; Niu, Linqiang; Huang, Jing; Yan, Zhijie; Wang, Jianhong

    2018-03-01

    Biothiols, such as cysteine (Cys), homocysteine (Hcy) and glutathione (GSH), are involved in a number of biological processes and play crucial roles in biological systems. Thus, the detection of biothiols is highly important for early diagnosis of diseases and evaluation of disease progression. Herein, we developed a new turn-on fluorescent probe 1 based on 7-nitro-2,1,3-benzoxadiazole (NBD) with high selectivity and sensitivity for Cys/Hcy on account of nucleophilic substitution and Smiles rearrangement reaction. The probe could sense Cys/Hcy rapidly, the intensity of fluorescence increased immediately within 1 min. Furthermore, the probe is low toxic and has been successfully applied to detect intracellular Cys/Hcy by cell fluorescence imaging in living normal and cancer cells.

  6. Detecting long-term low-irradiance stress and water stress of trees with laser-induced fluorescence measurements

    International Nuclear Information System (INIS)

    Sagawa, M.; Kurata, K.; Takahashi, K.; Mineuchi, K.

    2001-01-01

    The objective of this study was to find simple and objective methods of diagnosing the ailments of trees in indoor spaces, such as atriums. In this study, two simple diagnostics were compared. One was the analysis of the laser-induced fluorescence spectra of leaves and the other was the analysis of the laser-induced chlorophyll-fluorescence induction kinetics (Kautsky effect). In the latter analysis, second time derivatives of the induction-kinetics curves were used. Cinnamomum camphora and Quercus myrsinifolia grown under different light conditions and Cinnamomum camphora under water stress were used in the experiments. The effects of low irradiance were detected in both the induction kinetics and the spectra; however, the effects of water stress were detected in the induction kinetics only. These results indicate the possibility of utilizing laser-induced-fluorescence induction-kinetics for diagnosing the ailments of trees. (author)

  7. Multiplex fluorescence melting curve analysis for mutation detection with dual-labeled, self-quenched probes.

    Directory of Open Access Journals (Sweden)

    Qiuying Huang

    2011-04-01

    Full Text Available Probe-based fluorescence melting curve analysis (FMCA is a powerful tool for mutation detection based on melting temperature generated by thermal denaturation of the probe-target hybrid. Nevertheless, the color multiplexing, probe design, and cross-platform compatibility remain to be limited by using existing probe chemistries. We hereby explored two dual-labeled, self-quenched probes, TaqMan and shared-stem molecular beacons, in their ability to conduct FMCA. Both probes could be directly used for FMCA and readily integrated with closed-tube amplicon hybridization under asymmetric PCR conditions. Improved flexibility of FMCA by using these probes was illustrated in three representative applications of FMCA: mutation scanning, mutation identification and mutation genotyping, all of which achieved improved color-multiplexing with easy probe design and versatile probe combination and all were validated with a large number of real clinical samples. The universal cross-platform compatibility of these probes-based FMCA was also demonstrated by a 4-color mutation genotyping assay performed on five different real-time PCR instruments. The dual-labeled, self-quenched probes offered unprecedented combined advantage of enhanced multiplexing, improved flexibility in probe design, and expanded cross-platform compatibility, which would substantially improve FMCA in mutation detection of various applications.

  8. Mobile low power total reflexion x-ray fluorescence spectrometer with pg-detection-limit

    Energy Technology Data Exchange (ETDEWEB)

    Dietsch, R.; Holz, Th.; Mai, H. [Fraunhofer Institute Material and Beam Technology, Dresden, (Germany); Waldschlaeger, U. [I.U.T. GmbH, Berlin, (Germany)

    1999-12-01

    Full text: Total reflexion x-ray fluorescence (TXRF) spectrometry is an efficient tool in trace element analysis. Conventional laboratory spectrometers can achieve detection limits in the pg-range. Unfortunately high power X-ray tubes (i.e. some kW) and LN{sub 2}-cooled Si(Li)-detectors are sometimes not applicable within mobile TXRF-spectrometers. Therefore a portable device for TXRF (PicoTAX{sub PS}) has been developed and the latest results will be presented. This device is a very compact combination of an air-cooled low power X-ray tube (Mo-anode, 40W) a Peltier-cooled PlN-diode detector and a high quality flat primary Ni/C X-ray mirror (2t= 7.84 nm, N100, R> 80%). The background radiation is reduced by means of this particular mirror. That way the achievable detection limits are comparable with conventional 1.5 kW TXRF- spectrometers. The characteristic parameters of X-ray source, detector and Ni/C mirror will be presented. Additionally, the performance of this portable TXRF-system will be demonstrated by selected examples. Copyright (1999) Australian X-ray Analytical Association Inc. 1 fig.

  9. Fundus auto fluorescence and spectral domain ocular coherence tomography in the early detection of chloroquine retinopathy

    Directory of Open Access Journals (Sweden)

    Megan B. Goodman

    2015-08-01

    Full Text Available Purpose: To determine the sensitivity of spectral domain ocular coherence tomography (SD-OCT and fundus auto fluorescence (FAF images as a screening test to detect early changes in the retina prior to the onset of chloroquine retinopathy. Method: The study was conducted using patients taking chloroquine (CQ, referred by the Rheumatology Department to the Ophthalmology Department at Tygerberg Academic Hospital. Group A consisted of 59 patients on CQ for less than 5 years, and Group B consisted of 53 patients on CQ for more than 5 years. A 200 × 200 macula thickness map, 5-line raster SD-OCT on a Carl Zeiss Meditec Cirrus HD-OCT and FAF images on a Carl Zeiss Meditec Visucam 500 were recorded for 223 eyes. Images were reviewed independently, and then those of Groups A and B compared. Results: There were no statistically significant differences between Groups A and B. The criteria included the internal limiting membrane and the retinal pigment epithelium (ILM-RPE thickness, interdigitation zone integrity (p = 0.891, df = 1, χ² = 0.1876, ellipsoid zone integrity (p = 0.095, df = 2, χ² = 4.699 and FAF image irregularities (p = 0.479, df = 1, χ²= 4995978. Conclusion: The inclusion of SD-OCT and FAF as objective tests into the prescribed screening guidelines does not appear to simplify the detection of subclinical injury in patients on chloroquine treatment.

  10. Multiresidue determination of quinolone antibacterials in eggs of laying hens by liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Hassouan, M K; Ballesteros, O; Taoufiki, J; Vílchez, J L; Cabrera-Aguilera, M; Navalón, A

    2007-06-01

    An analytical method for the simultaneous determination of seven quinolones (ciprofloxacin, enrofloxacin, danofloxacin, difloxacin, flumequine, oxolinic acid and sarafloxacin) in egg samples of laying hens was developed. Their use is totally prohibited in animals from which eggs are produced for human consumption. Protein precipitation was achieved by addition of acetonitrile and ammonia, removal of acetonitrile with dichloromethane, the quinolones remaining in the basic aqueous extract. The aqueous extract was analysed by liquid chromatography with fluorescence detection (LC-FD). The mobile phase was composed of acetonitrile and 10 mM citrate buffer solution of pH 4.5, with an initial composition of acetonitrile-water (12:88, v/v) and using linear gradient elution. Norfloxacin was used as an internal standard. The limits of detection found were 4-12 ng g(-1). These values were lower than the maximum residue limits (MRLs) established by the European Union for these compounds in different tissues of eggs-producing animals.

  11. Detection of genetically altered copper levels in Drosophila tissues by synchrotron x-ray fluorescence microscopy.

    Directory of Open Access Journals (Sweden)

    Jessica C Lye

    Full Text Available Tissue-specific manipulation of known copper transport genes in Drosophila tissues results in phenotypes that are presumably due to an alteration in copper levels in the targeted cells. However direct confirmation of this has to date been technically challenging. Measures of cellular copper content such as expression levels of copper-responsive genes or cuproenzyme activity levels, while useful, are indirect. First-generation copper-sensitive fluorophores show promise but currently lack the sensitivity required to detect subtle changes in copper levels. Moreover such techniques do not provide information regarding other relevant biometals such as zinc or iron. Traditional techniques for measuring elemental composition such as inductively coupled plasma mass spectroscopy are not sensitive enough for use with the small tissue amounts available in Drosophila research. Here we present synchrotron x-ray fluorescence microscopy analysis of two different Drosophila tissues, the larval wing imaginal disc, and sectioned adult fly heads and show that this technique can be used to detect changes in tissue copper levels caused by targeted manipulation of known copper homeostasis genes.

  12. Metal-organic gel enhanced fluorescence anisotropy for sensitive detection of prostate specific antigen

    Science.gov (United States)

    Zhao, Ting Ting; Peng, Zhe Wei; Yuan, Dan; Zhen, Shu Jun; Huang, Cheng Zhi; Li, Yuan Fang

    2018-03-01

    In this contribution, we demonstrated that Cu-based metal-organic gel (Cu-MOG) was able to serve as a novel amplification platform for fluorescence anisotropy (FA) assay for the first time, which was confirmed by the sensitive detection of a common cancer biomarker, prostate specific antigen (PSA). The dye-labeled probe aptamer (PA) product was adsorbed onto the benzimidazole derivative-containing Cu-MOG via electrostatic incorporation and strong π-π stacking interactions, which significantly increased the FA value due to the enlargement of the molecular volume of the PA/Cu-MOG complex. With the introduction of target PSA, the FA value was obviously decreased on account of the specific recognition between PSA and PA which resulted in the detachment of PA from the surface of MOG. The linear range was from 0.5-8 ng/mL, with a detection limit of 0.33 ng/mL. Our work has thus helped to demonstrate promising application of MOG material in the fields of biomolecules analysis and disease diagnosis.

  13. Molecular engineering of a fluorescent bioprobe for sensitive and selective detection of amphibole asbestos.

    Directory of Open Access Journals (Sweden)

    Takenori Ishida

    Full Text Available Fluorescence microscopy-based affinity assay could enable highly sensitive and selective detection of airborne asbestos, an inorganic environmental pollutant that can cause mesothelioma and lung cancer. We have selected an Escherichia coli histone-like nucleoid structuring protein, H-NS, as a promising candidate for an amphibole asbestos bioprobe. H-NS has high affinity to amphibole asbestos, but also binds to an increasingly common asbestos substitute, wollastonite. To develop a highly specific Bioprobe for amphibole asbestos, we first identified a specific but low-affinity amosite-binding sequence by slicing H-NS into several fragments. Second, we constructed a streptavidin tetramer complex displaying four amosite-binding fragments, resulting in the 250-fold increase in the probe affinity as compared to the single fragment. The tetramer probe had sufficient affinity and specificity for detecting all the five types of asbestos in the amphibole group, and could be used to distinguish them from wollastonite. In order to clarify the binding mechanism and identify the amino acid residues contributing to the probe's affinity to amosite fibers, we constructed a number of shorter and substituted peptides. We found that the probable binding mechanism is electrostatic interaction, with positively charged side chains of lysine residues being primarily responsible for the probe's affinity to asbestos.

  14. Early tumor detection afforded by in vivo imaging of near-infrared II fluorescence.

    Science.gov (United States)

    Tao, Zhimin; Dang, Xiangnan; Huang, Xing; Muzumdar, Mandar D; Xu, Eric S; Bardhan, Neelkanth Manoj; Song, Haiqin; Qi, Ruogu; Yu, Yingjie; Li, Ting; Wei, Wei; Wyckoff, Jeffrey; Birrer, Michael J; Belcher, Angela M; Ghoroghchian, P Peter

    2017-07-01

    Cell-intrinsic reporters such as luciferase (LUC) and red fluorescent protein (RFP) have been commonly utilized in preclinical studies to image tumor growth and to monitor therapeutic responses. While extrinsic reporters that emit near infrared I (NIR-I: 650-950 nm) or near-infrared II (NIR-II: 1000-1700 nm) optical signals have enabled minimization of tissue autofluorescence and light scattering, it has remained unclear as to whether their use has afforded more accurate tumor imaging in small animals. Here, we developed a novel optical imaging construct comprised of rare earth lanthanide nanoparticles coated with biodegradable diblock copolymers and doped with organic fluorophores, generating NIR-I and NIR-II emissive bands upon optical excitation. Simultaneous injection of multiple spectrally-unique nanoparticles into mice bearing tumor implants established via intraperitoneal dissemination of LUC + /RFP + OVCAR-8 ovarian cancer cells enabled direct comparisons of imaging with extrinsic vs. intrinsic reporters, NIR-II vs. NIR-I signals, as well as targeted vs. untargeted exogenous contrast agents in the same animal and over time. We discovered that in vivo optical imaging at NIR-II wavelengths facilitates more accurate detection of smaller and earlier tumor deposits, offering enhanced sensitivity, improved spatial contrast, and increased depths of tissue penetration as compared to imaging with visible or NIR-I fluorescent agents. Our work further highlights the hitherto underappreciated enhancements in tumor accumulation that may be achieved with intraperitoneal as opposed to intravenous administration of nanoparticles. Lastly, we found discrepancies in the fidelity of tumor uptake that could be obtained by utilizing small molecules for in vivo as opposed to in vitro targeting of nanoparticles to disseminated tumors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Kerosene detection using laser induced fluorescence imaging for aeronautical engines application; Detection du kerozene par imagerie de fluorescence induite par laser, pour application sur foyer aeronautique

    Energy Technology Data Exchange (ETDEWEB)

    Baranger, Ph.

    2004-10-15

    The new concepts of aeronautical engines, developed to follow the evolution of the European standards of pollution, are generally based on an improvement of the processes of liquid fuel injection and mixture in the combustion chamber. There is currently no model mature enough to work without experimental validation. The purpose of this thesis is to assess the possibility of measuring the kerosene (Jet A1) vapour distribution by PLIF (Planar Laser Induced Fluorescence). That measurement technique must quantitatively image the instantaneous concentrations fields of the vaporized fuel in a spray. The implementation of such a technique needs an experimental spectroscopic study, which was realized on the vapour of fuel. First of all, this study allowed us to determine the properties of the kerosene fluorescence spectrum versus physical parameters such as temperature, pressure or gas mixture composition, especially in presence of oxygen molecules. Then, it was shown that the fluorescence spectrum of the fuel could be reproduce in all physical conditions by a single mixture of four aromatics. Their photophysical properties were also analyzed. Following this spectroscopic study, a phenomenological model for the fluorescence of the gaseous fuel was set up. This model led us to a protocol for an optical diagnostic on this fuel vapour. An experiment was set up to test the implementation and the limits of this technique in simple laboratory conditions. This experiment confirmed that this is indeed a promising technique for the diagnostic of the fuel vapour in aeronautical engine. (author)

  16. One- and two-photon induced fluorescence spectroscopy enabling the detection of localized aflatoxin contamination in individual maize kernels

    Science.gov (United States)

    Smeesters, L.; Meulebroeck, W.; Raeymaekers, S.; Thienpont, H.

    2016-04-01

    The presence of carcinogenic aflatoxins in food and feed products is a major worldwide problem. To date, the aflatoxin contamination can only be detected by the use of destructive sample-based chemical analyses. Therefore, we developed an optical setup able to detect the localized aflatoxin contamination in individual maize kernels, on the basis of one- and two- photon induced fluorescence spectroscopy. Our developed optical configuration comprises a tunable titanium-sapphire laser (710nm-830nm) in combination with second harmonic wavelength generation (355nm-415nm), enabling the measurement of both one- and two-photon induced fluorescence spectra. Moreover, an accurate scanning of the kernel's surface was induced by the use of automated translation stages, allowing to study the localized maize contamination. First, the operation of the setup is validated by the characterization of pure aflatoxin B1 powder. Second, the fluorescence spectra of healthy (aflatoxin B1) and contaminated maize kernels (>70ppb aflatoxin B1) were measured, after excitation with 365nm, 730nm, 750nm and 780nm. For both the one- and two- photon induced fluorescence processes, the presence of the aflatoxin inside the contaminated maize kernels influenced the intrinsic fluorescence signals. Based on the fluorescence spectrum between 400nm and 550nm, we defined a detection criterion to identify the contaminated maize kernels. Furthermore, we demonstrate the sensing of the localized contamination level, indicating both contaminated maize kernels with a high contamination level in a limited surface area (as small as 1mm2) as with a lower contamination spread over a large surface area (up to 20mm2). As a result, our developed measurement methodology allows the identification of the localized aflatoxin contamination, paving the way to the non-destructive, real-time and high-sensitive industrial scanning-based detection of aflatoxins in food products.

  17. APTS and rGO co-functionalized pyrenated fluorescent nanonets for representative vapor phase nitroaromatic explosive detection

    Science.gov (United States)

    Guo, Linjuan; Zu, Baiyi; Yang, Zheng; Cao, Hongyu; Zheng, Xuefang; Dou, Xincun

    2014-01-01

    For the first time, flexible PVP/pyrene/APTS/rGO fluorescent nanonets were designed and synthesized via a one-step electrospinning method to detect representative subsaturated nitroaromatic explosive vapor. The functional fluorescent nanonets, which were highly stable in air, showed an 81% quenching efficiency towards TNT vapor (~10 ppb) with an exposure time of 540 s at room temperature. The nice performance of the nanonets was ascribed to the synergistic effects induced by the specific adsorption properties of APTS, the fast charge transfer properties and the effective π-π interaction with pyrene and TNT of rGO. Compared to the analogues of TNT, the PVP/pyrene/APTS/rGO nanonets showed notable selectivity towards TNT and DNT vapors. The explored functionalization method opens up brand new insight into sensitive and selective detection of vapor phase nitroaromatic explosives.For the first time, flexible PVP/pyrene/APTS/rGO fluorescent nanonets were designed and synthesized via a one-step electrospinning method to detect representative subsaturated nitroaromatic explosive vapor. The functional fluorescent nanonets, which were highly stable in air, showed an 81% quenching efficiency towards TNT vapor (~10 ppb) with an exposure time of 540 s at room temperature. The nice performance of the nanonets was ascribed to the synergistic effects induced by the specific adsorption properties of APTS, the fast charge transfer properties and the effective π-π interaction with pyrene and TNT of rGO. Compared to the analogues of TNT, the PVP/pyrene/APTS/rGO nanonets showed notable selectivity towards TNT and DNT vapors. The explored functionalization method opens up brand new insight into sensitive and selective detection of vapor phase nitroaromatic explosives. Electronic supplementary information (ESI) available: Vapor pressure of TNT and its analogues, fluorescence quenching kinetics, fluorescence quenching efficiencies and additional SEM images. See DOI: 10.1039/c3nr04960d

  18. Protein Nano-Object Integrator (ProNOI for generating atomic style objects for molecular modeling

    Directory of Open Access Journals (Sweden)

    Smith Nicholas

    2012-12-01

    Full Text Available Abstract Background With the progress of nanotechnology, one frequently has to model biological macromolecules simultaneously with nano-objects. However, the atomic structures of the nano objects are typically not available or they are solid state entities. Because of that, the researchers have to investigate such nano systems by generating models of the nano objects in a manner that the existing software be able to carry the simulations. In addition, it should allow generating composite objects with complex shape by combining basic geometrical figures and embedding biological macromolecules within the system. Results Here we report the Protein Nano-Object Integrator (ProNOI which allows for generating atomic-style geometrical objects with user desired shape and dimensions. Unlimited number of objects can be created and combined with biological macromolecules in Protein Data Bank (PDB format file. Once the objects are generated, the users can use sliders to manipulate their shape, dimension and absolute position. In addition, the software offers the option to charge the objects with either specified surface or volumetric charge density and to model them with user-desired dielectric constants. According to the user preference, the biological macromolecule atoms can be assigned charges and radii according to four different force fields: Amber, Charmm, OPLS and PARSE. The biological macromolecules and the atomic-style objects are exported as a position, charge and radius (PQR file, or if a default dielectric constant distribution is not selected, it is exported as a position, charge, radius and epsilon (PQRE file. As illustration of the capabilities of the ProNOI, we created a composite object in a shape of a robot, aptly named the Clemson Robot, whose parts are charged with various volumetric charge densities and holds the barnase-barstar protein complex in its hand. Conclusions The Protein Nano-Object Integrator (ProNOI is a convenient tool for

  19. Nitrogen and Sulfur Codoped Reduced Graphene Oxide as a General Platform for Rapid and Sensitive Fluorescent Detection of Biological Species.

    Science.gov (United States)

    Chen, Lu; Song, Liping; Zhang, Yichi; Wang, Ping; Xiao, Zhidong; Guo, Yuguo; Cao, Feifei

    2016-05-11

    Nitrogen (N) and sulfur (S) codoped reduced graphene oxide (N,S-rGO) was synthesized through a facile solvothermal process. The introduction of N and S heteroatoms into GO effectively activated the sp(2)-hybridized carbon lattice and made the material an ideal electron/energy acceptor. Such unique properties enable this material to perform as a general platform for rapid and sensitive detection of various biological species through simple fluorescence quenching and recovering. When quantum dot (QD)-labeled HBV (human being disease-related gene hepatitis B virus DNA) and HIV (human being disease-related gene human immunodeficiency virus DNA) molecular beacon probes were mixed with N,S-rGO, QD fluorescence was quenched; when target HBV and HIV DNA were added, QD fluorescence was recovered. By the recovered fluorescence intensity, the target virus DNA detection limits were reduced to 2.4 nM for HBV and 3.0 nM for HIV with detection time of less than 5 min. It must be stressed out that different viruses in the same homogeneous aqueous media could be discriminated and quantified simultaneously through choosing diverse QD probes with different colors. Moreover, even one mismatched target DNA could be distinguished using this method. When altering the molecular beacon loop domain to protein aptamers, this sensing strategy was also able to detect thrombin and IgE in 5 min with detection limits of 0.17 ng mL(-1) and 0.19 ng mL(-1), respectively, which was far more rapid and sensitive than bare GO-based fluorescence detection strategy.

  20. Intraoperative Multispectral Fluorescence Imaging for the Detection of the Sentinel Lymph Node in Cervical Cancer : A Novel Concept

    NARCIS (Netherlands)

    Crane, Lucia M. A.; Themelis, George; Pleijhuis, Rick G.; Harlaar, Niels J.; Sarantopoulos, Athanasios; Arts, Henriette J. G.; van der Zee, Ate G. J.; Vasilis, Ntziachristos; van Dam, Gooitzen M.

    2011-01-01

    Real-time intraoperative near-infrared fluorescence (NIRF) imaging is a promising technique for lymphatic mapping and sentinel lymph node (SLN) detection. The purpose of this technical feasibility pilot study was to evaluate the applicability of NIRF imaging with indocyanin green (ICG) for the

  1. Ratiometric fluorescence detection of superoxide anion based on AuNPs-BSA@Tb/GMP nanoscale coordination polymers.

    Science.gov (United States)

    Liu, Nan; Hao, Juan; Cai, Keying; Zeng, Mulan; Huang, Zhenzhong; Chen, Lili; Peng, Bingxian; Li, Ping; Wang, Li; Song, Yonghai

    2018-02-01

    A novel ratiometric fluorescence nanosensor for superoxide anion (O 2 •- ) detection was designed with gold nanoparticles-bovine serum albumin (AuNPs-BSA)@terbium/guanosine monophosphate disodium (Tb/GMP) nanoscale coordination polymers (NCPs) (AuNPs-BSA@Tb/GMP NCPs). The abundant hydroxyl and amino groups of AuNPs-BSA acted as binding points for the self-assembly of Tb 3+ and GMP to form core-shell AuNPs-BSA@Tb/GMP NCP nanosensors. The obtained probe exhibited the characteristic fluorescence emission of both AuNPs-BSA and Tb/GMP NCPs. The AuNPs-BSA not only acted as a template to accelerate the growth of Tb/GMP NCPs, but also could be used as the reference fluorescence for the detection of O 2 •- . The resulting AuNPs-BSA@Tb/GMP NCP ratiometric fluorescence nanosensor for the detection of O 2 •- demonstrated high sensitivity and selectivity with a wide linear response range (14 nM-10 μM) and a low detection limit (4.7 nM). Copyright © 2017 John Wiley & Sons, Ltd.

  2. Sensitive spectroscopic detection of large and denatured protein aggregates in solution by use of the fluorescent dye Nile re

    NARCIS (Netherlands)

    Sutter, M.; Oliveira, S.; Sanders, N.N.; Lucas, B.; Hoek, van A.; Hink, M.A.; Visser, A.J.W.G.; Smedt, de S.C.; Hennink, W.E.; Jiskoot, W.

    2007-01-01

    The fluorescent dye Nile red was used as a probe for the sensitive detection of large, denatured aggregates of the model protein ß-galactosidase (E. coli) in solution. Aggregates were formed by irreversible heat denaturation of ß-galactosidase below and above the protein¿s unfolding temperature of

  3. Highly sensitive turn-on fluorescent detection of captopril based on energy transfer between fluorescein isothiocyanate and gold nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Hormozi-Nezhad, M. Reza, E-mail: hormozi@sharif.edu [Department of Chemistry, Sharif University of Technology, Tehran 11155-9516 (Iran, Islamic Republic of); Institute for Nanoscience and Nanotechnology, Sharif University of Technology, Tehran, PO Box 11365-9161 (Iran, Islamic Republic of); Bagheri, H.; Bohloul, A.; Taheri, N.; Robatjazi, H. [Department of Chemistry, Sharif University of Technology, Tehran 11155-9516 (Iran, Islamic Republic of)

    2013-02-15

    A novel approach for highly sensitive detection of captopril was developed based on the fluorescence resonance energy transfer (FRET) between gold nanoparticles (Au NPs) and fluorescein isothiocyanate (FITC), in which FITC acts as the donor and Au NPs as the acceptor. The fluorescence intensity of fluorescein isothiocyanate (FITC) was strictly quenched as a result of noncovalently adsorbed on Au NPs. Upon the addition of captopril, the fluorescence intensity of FITC 'turn-on' due to the competition between captopril and FITC towards the surface of Au NPs. Under the optimum conditions, the fluorescence intensity of the released FITC displays a linear relationship in the range of 20 {mu}g L{sup -1} to 500 {mu}g L{sup -1} of captopril. Lower limit of detection for captopril, at the signal-to-noise ratio of 3 (3{sigma}), was 2.6 {mu}g L{sup -1}. The developed methodology was successfully applied for the determination of captopril in human plasma. - Highlights: Black-Right-Pointing-Pointer Detection of Captopril at PPb levels using FRET method. Black-Right-Pointing-Pointer We study effect of variables on FRET process for determination of Captopril. Black-Right-Pointing-Pointer Detecting Captopril in real samples e.g. Human plasma.

  4. A novel fluorescent biosensor for Adenosine Triphosphate detection based on the polydopamine nanospheres integrating with enzymatic recycling amplification.

    Science.gov (United States)

    Ji, Xiaoting; Yi, Bingqing; Xu, Yujuan; Zhao, Yanan; Zhong, Hua; Ding, Caifeng

    2017-07-01

    Based on the protective performance of polydopamine nanospheres (PDANSs) for DNA against nuclease digestion and the specific recognition characteristic of aptamer, we have developed an enzymatic recycling signal amplification method for highly sensitive and selective detection of adenosine triphosphate (ATP). Fluorescence measurements were carried out to verify the DNA polymerase and exonuclease III (Exo III) assisted target recycling process and fluorescence signal amplification. In the absence of the ATP, initially, the signal DNA-PDANSs complex was in the "off" state due to the efficient fluorescence quenching of 6-carboxyfluorescein (FAM) adjacent to the surface of PDANSs. Due to the binding of the aptamer by ATP, it trigger DNA polymerase and Exo III assisted target recycling process by the product of release, the complex would change into the "on" state as a result of the dissociation of the FAM from the surface of PDANSs, thus providing greatly enhanced fluorescence emission intensity. The method allows quantitative detection of ATP in the range of 20-600nM with a detection limit of 8.32nM. This biosensor requires no complex operations, and is a new high efficiency method for ATP detection. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Fluorescent detection of dipicolinic acid as a biomarker of bacterial spores using lanthanide-chelated gold nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Donmez, Mert [Department of Chemistry, Faculty of Art and Sciences, Duzce University, Duzce 81620 (Turkey); Yilmaz, M. Deniz, E-mail: deniz.yilmaz@gidatarim.edu.tr [Department of Bioengineering, Faculty of Engineering and Architecture, Konya Food and Agriculture University, Konya 42080 (Turkey); Kilbas, Benan, E-mail: benankilbas@duzce.edu.tr [Department of Chemistry, Faculty of Art and Sciences, Duzce University, Duzce 81620 (Turkey)

    2017-02-15

    Highlights: • The nanosensors based on gold nanoparticles functionalized with lanthanide complexes were synthesized. • The nanosensors selectively and sensitively detected DPA, a biomarker of bacterial spores. • Ratiometric sensing of DPA by a ternary complex was achieved by ligand displacement strategy. - Abstract: Gold nanoparticles (GNPs) functionalized with ethylenediamine-lanthanide complexes (Eu-GNPs and Tb-GNPs) were used for the selective fluorescent detection of dipicolinic acid (DPA), a unique biomarker of bacterial spores, in water. Particles were characterized by transmission electron microscopy and zeta potential measurements. The coordination of DPA to the lanthanides resulted in the enhancement of the fluorescence. A selective response to DPA was observed over the nonselective binding of aromatic ligands. The ligand displacement strategy were also employed for the ratiometric fluorescent detection of DPA. 4,4,4-trifluoro-1-(2-naphthyl)-1,3-butanedion (TFNB) was chosen as an antenna to synthesize ternary complexes. The addition of DPA on EuGNP:TFNB ternary complex quenched the initial emission of the complex at 615 nm and increased the TFNB emission at 450 nm when excited at 350 nm. The results demonstrated that the ratiometric fluorescent detection of DPA was achieved by ligand displacement strategy.

  6. Detection of Silver Nanoparticles in Cells by Flow Cytometry Using Light Scattering and Far-red Fluorescence

    Science.gov (United States)

    The cellular uptake of different sized silver nanoparticles (l0 nm, 50 nm, and 75nm) coated with polyvinylpyrrolidone (PVP) or citrate in ARPE-19 cells following 24 hour incubation was detected by side scatter through the use of a flow cytometer. A large far red fluorescence sign...

  7. Sensitive determination of specific radioactivity of positron emission tomography radiopharmaceuticals by radio high-performance liquid chromatography with fluorescence detection.

    Science.gov (United States)

    Nakao, Ryuji; Furutsuka, Kenji; Yamaguchi, Masatoshi; Suzuki, Kazutoshi

    2008-10-01

    A sensitive quality control method is often required in positron emission tomography (PET) radiopharmaceutical analysis due to the high specific radioactivity of synthetic products. The applicability of a radio high-performance liquid chromatography (HPLC) method with fluorescence detection was evaluated for a wide variety of PET radiopharmaceuticals. In 29 different radiopharmaceuticals studied, 20 compounds exhibited native fluorescence. These properties enabled sensitive determination of their chemical masses by direct fluorimetric detection after separation by HPLC. For some substances, detection limits were below nanograms per milliliter level, at least 40 times better than current UV absorbance detection. Sufficient reproducibility and linearity were obtained for the analysis of pharmaceutical fluid. Post-column fluorimetric derivatization was also established for the quantitative determination of FDG and ClDG in [(18)F]FDG samples. These methods could be applied successfully to the analysis of PET radiopharmaceuticals with ultra-high specific radioactivity.

  8. First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range

    Directory of Open Access Journals (Sweden)

    Anita J. Crompton

    2017-11-01

    Full Text Available In this work, a robust stand-off alpha detection method using the secondary effects of alpha radiation has been sought. Alpha particles ionise the surrounding atmosphere as they travel. Fluorescence photons produced as a consequence of this can be used to detect the source of the alpha emissions. This paper details experiments carried out to detect this fluorescence, with the focus on photons in the ultraviolet C (UVC wavelength range (180–280 nm. A detector, UVTron R9533 (Hamamatsu, 325-6, Sunayama-cho, Naka-ku, Hamamatsu City, Shizuoka Pref., 430-8587, Japan, designed to detect the UVC emissions from flames for fire alarm purposes, was tested in various gas atmospheres with a 210Po alpha source to determine if this could provide an avenue for stand-off alpha detection. The results of the experiments show that this detector is capable of detecting alpha-induced air fluorescence in normal indoor lighting conditions, as the interference from daylight and artificial lighting is less influential on this detection system which operates below the UVA and UVB wavelength ranges (280–315 nm and 315–380 nm respectively. Assuming a standard 1 r 2 drop off in signal, the limit of detection in this configuration can be calculated to be approximately 240 mm, well beyond the range of alpha-particles in air, which indicates that this approach could have potential for stand-off alpha detection. The gas atmospheres tested produced an increase in the detector count, with xenon having the greatest effect with a measured 52% increase in the detector response in comparison to the detector response in an air atmosphere. This type of alpha detection system could be operated at a distance, where it would potentially provide a more cost effective, safer, and faster solution in comparison with traditional alpha detection methods to detect and characterise alpha contamination in nuclear decommissioning and security applications.

  9. First Results of Using a UVTron Flame Sensor to Detect Alpha-Induced Air Fluorescence in the UVC Wavelength Range.

    Science.gov (United States)

    Crompton, Anita J; Gamage, Kelum A A; Bell, Steven; Wilson, Andrew P; Jenkins, Alex; Trivedi, Divyesh

    2017-11-29

    In this work, a robust stand-off alpha detection method using the secondary effects of alpha radiation has been sought. Alpha particles ionise the surrounding atmosphere as they travel. Fluorescence photons produced as a consequence of this can be used to detect the source of the alpha emissions. This paper details experiments carried out to detect this fluorescence, with the focus on photons in the ultraviolet C (UVC) wavelength range (180-280 nm). A detector, UVTron R9533 (Hamamatsu, 325-6, Sunayama-cho, Naka-ku, Hamamatsu City, Shizuoka Pref., 430-8587, Japan), designed to detect the UVC emissions from flames for fire alarm purposes, was tested in various gas atmospheres with a 210 Po alpha source to determine if this could provide an avenue for stand-off alpha detection. The results of the experiments show that this detector is capable of detecting alpha-induced air fluorescence in normal indoor lighting conditions, as the interference from daylight and artificial lighting is less influential on this detection system which operates below the UVA and UVB wavelength ranges (280-315 nm and 315-380 nm respectively). Assuming a standard 1 r 2 drop off in signal, the limit of detection in this configuration can be calculated to be approximately 240 mm, well beyond the range of alpha-particles in air, which indicates that this approach could have potential for stand-off alpha detection. The gas atmospheres tested produced an increase in the detector count, with xenon having the greatest effect with a measured 52% increase in the detector response in comparison to the detector response in an air atmosphere. This type of alpha detection system could be operated at a distance, where it would potentially provide a more cost effective, safer, and faster solution in comparison with traditional alpha detection methods to detect and characterise alpha contamination in nuclear decommissioning and security applications.

  10. Subunits of highly Fluorescent Protein R-Phycoerythrin as Probes for Cell Imaging and Single-Molecule Detection

    Energy Technology Data Exchange (ETDEWEB)

    Isailovic, Dragan [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The purposes of our research were: (1) To characterize subunits of highly fluorescent protein R-Phycoerythrin (R-PE) and check their suitability for single-molecule detection (SMD) and cell imaging, (2) To extend the use of R-PE subunits through design of similar proteins that will be used as probes for microscopy and spectral imaging in a single cell, and (3) To demonstrate a high-throughput spectral imaging method that will rival spectral flow cytometry in the analysis of individual cells. We first demonstrated that R-PE subunits have spectroscopic and structural characteristics that make them suitable for SMD. Subunits were isolated from R-PE by high-performance liquid chromatography (HPLC) and detected as single molecules by total internal reflection fluorescence microscopy (TIRFM). In addition, R-PE subunits and their enzymatic digests were characterized by several separation and detection methods including HPLC, capillary electrophoresis, sodium dodecyl sulfate-polyacrilamide gel electrophoresis (SDS-PAGE) and HPLC-electrospray ionization mass spectrometry (ESI-MS). Favorable absorption and fluorescence of the R-PE subunits and digest peptides originate from phycoerythrobilin (PEB) and phycourobilin (PUB) chromophores that are covalently attached to cysteine residues. High absorption coefficients and strong fluorescence (even under denaturing conditions), broad excitation and emission fluorescence spectra in the visible region of electromagnetic spectrum, and relatively low molecular weights make these molecules suitable for use as fluorescence labels of biomolecules and cells. We further designed fluorescent proteins both in vitro and in vivo (in Escherichia coli) based on the highly specific attachment of PEB chromophore to genetically expressed apo-subunits of R-PE. In one example, apo-alpha and apo-beta R-PE subunits were cloned from red algae Polisiphonia boldii (P. boldii), and expressed in E. coli. Although expressed apo-subunits formed inclusion

  11. A fluorescence-quenching platform based on biomineralized hydroxyapatite from natural seashell and applied to cancer cell detection.

    Science.gov (United States)

    Zhang, Ying; Liu, Wei; Banks, Craig E; Liu, Fei; Li, Mao; Xia, Fan; Yang, Xiangliang

    2014-12-19

    As a typical biomineral, hydroxyapatite (HAp) is widely applied in bone implants and other related fields. However, the inherent nature of HAp can potentially be altered through restricting its fabrication conditions. Here, HAp fabricated by a hydrothermal treatment of pieces of natural seashell is demonstrated to have the capability of fluorescence quenching. To the best of the author's knowledge, this is the first time that this new property of HAp has been reported. Consequently, we assembled a fluorescence-quenching platform based on the biomineralized HAp substrate following a hydrothermal treatment and associated with a DNA molecular beacon and applied to cancer cell detection by the transformation from "OFF state" (fluorescence quenching) to "ON state" (fluorescence recovery). Herein, we found that the outer surface of HAp material after hydrothermal biomineralization for 5 days has considerable capability for both fluorescence quenching and recovery. These results may also have implications in the further detection of various targets such as cancer cells with other special surface antigens, significant biological small molecules or disease related microRNA, just by changing the sequence of the nucleic acid beacon according to the corresponding aptamer.

  12. Label-free fluorescence strategy for sensitive detection of adenosine triphosphate using a loop DNA probe with low background noise.

    Science.gov (United States)

    Lin, Chunshui; Cai, Zhixiong; Wang, Yiru; Zhu, Zhi; Yang, Chaoyong James; Chen, Xi

    2014-07-15

    A simple, rapid, label-free, and ultrasensitive fluorescence strategy for adenosine triphosphate (ATP) detection was developed using a loop DNA probe with low background noise. In this strategy, a loop DNA probe, which is the substrate for both ligation and digestion enzyme reaction, was designed. SYBR green I (SG I), a double-stranded specific dye, was applied for the readout fluorescence signal. Exonuclease I (Exo I) and exonuclease III (Exo III), sequence-independent nucleases, were selected to digest the loop DNA probe in order to minimize the background fluorescence signal. As a result, in the absence of ATP, the loop DNA was completely digested by Exo I and Exo III, leading to low background fluorescence owing to the weak electrostatic interaction between SG I and mononucleotides. On the other hand, ATP induced the ligation of the nicking site, and the sealed loop DNA resisted the digestion of Exo I and ExoIII, resulting in a remarkable increase of fluorescence response. Upon background noise reduction, the sensitivity of the ATP determination was improved significantly, and the detection limitation was found to be 1.2 pM, which is much lower than that in almost all the previously reported methods. This strategy has promise for wide application in the determination of ATP.

  13. Organic Liquids-Responsive β-Cyclodextrin-Functionalized Graphene-Based Fluorescence Probe: Label-Free Selective Detection of Tetrahydrofuran

    Directory of Open Access Journals (Sweden)

    Huawen Hu

    2014-06-01

    Full Text Available In this study, a label-free graphene-based fluorescence probe used for detection of volatile organic liquids was fabricated by a simple, efficient and low-cost method. To fabricate the probe, a bio-based β-cyclodextrin (β-CD was firstly grafted on reduced graphene surfaces effectively and uniformly, as evidenced by various characterization techniques such as Ultraviolet/Visible spectroscopy, Fourier transform infrared spectroscopy, X-ray diffraction, thermogravimetric analysis, scanning electron microscopy and transmission electron microscopy. The subsequent inclusion of Rhodamine B (RhB into the inner cavities of the β-CD grafted on the graphene surfaces was achieved easily by a solution mixing method, which yielded the graphene-based fluorescent switch-on probe. In addition, the gradual and controllable quenching of RhB by Fluorescence Resonance Energy Transfer from RhB to graphene during the process of stepwise accommodation of the RhB molecules into the β-CD-functionalized graphene was investigated in depth. A wide range of organic solvents was examined using the as-fabricated fluorescence probe, which revealed the highest sensitivity to tetrahydrofuran with the detection limit of about 1.7 μg/mL. Some insight into the mechanism of the different responsive behaviors of the fluorescence sensor to the examined targets was also described.

  14. Label-Free Fluorescent Detection of Trypsin Activity Based on DNA-Stabilized Silver Nanocluster-Peptide Conjugates

    Directory of Open Access Journals (Sweden)

    Cai-Xia Zhuo

    2016-11-01

    Full Text Available Trypsin is important during the regulation of pancreatic exocrine function. The detection of trypsin activity is currently limited because of the need for the substrate to be labeled with a fluorescent tag. A label-free fluorescent method has been developed to monitor trypsin activity. The designed peptide probe consists of six arginine molecules and a cysteine terminus and can be conjugated to DNA-stabilized silver nanoclusters (DNA-AgNCs by Ag-S bonding to enhance fluorescence. The peptide probe can also be adsorbed to the surface of graphene oxide (GO, thus resulting in the fluorescence quenching of DNA-AgNCs-peptide conjugate because of Förster resonance energy transfer. Once trypsin had degraded the peptide probe into amino acid residues, the DNA-AgNCs were released from the surface of GO, and the enhanced fluorescence of DNA-AgNCs was restored. Trypsin can be determined with a linear range of 0.0–50.0 ng/mL with a concentration as low as 1 ng/mL. This label-free method is simple and sensitive and has been successfully used for the determination of trypsin in serum. The method can also be modified to detect other proteases.

  15. Fluorescent probes concentration estimation in vitro and ex vivo as a model for early detection of Alzheimer's disease

    Science.gov (United States)

    Harbater, Osnat; Gannot, Israel

    2014-12-01

    The pathogenic process of Alzheimer's disease (AD) begins years before clinical diagnosis. Here, we suggest a method that may detect AD several years earlier than current exams. The method is based on previous reports that relate the concentration ratio of biomarkers (amyloid-beta and tau) in the cerebrospinal fluid (CSF) to the development of AD. Our method replaces the lumbar puncture process required for CSF drawing by using fluorescence measurements. The system uses an optical fiber coupled to a laser source and a detector. The laser radiation excites two fluorescent probes which may bond to the CSF biomarkers. Their concentration ratio is extracted from the fluorescence intensities and can be used for future AD detection. First, we present a theoretical model for fluorescence concentration ratio estimation. The method's feasibility was validated using Monte Carlo simulations. Its accuracy was then tested using multilayered tissue phantoms simulating the epidural fat, CSF, and bone. These phantoms have various optical properties, thicknesses, and fluorescence concentrations in order to simulate human anatomy variations and different fiber locations. The method was further tested using ex vivo chicken tissue. The average errors of the estimated concentration ratios were low both in vitro (4.4%) and ex vivo (10.9%), demonstrating high accuracy.

  16. Label-free detection of kanamycin based on a G-quadruplex DNA aptamer-based fluorescent intercalator displacement assay

    Science.gov (United States)

    Xing, Yun-Peng; Liu, Chun; Zhou, Xiao-Hong; Shi, Han-Chang

    2015-01-01

    This work was the first to report that the kanamycin-binding DNA aptamer (5'-TGG GGG TTG AGG CTA AGC CGA-3') can form stable parallel G-quadruplex DNA (G4-DNA) structures by themselves and that this phenomenon can be verified by nondenaturing polyacrylamide gel electrophoresis and circular dichroism spectroscopy. Based on these findings, we developed a novel label-free strategy for kanamycin detection based on the G4-DNA aptamer-based fluorescent intercalator displacement assay with thiazole orange (TO) as the fluorescence probe. In the proposed strategy, TO became strongly fluorescent upon binding to kanamycin-binding G4-DNA. However, the addition of kanamycin caused the displacement of TO from the G4-DNA-TO conjugate, thereby resulting in decreased fluorescent signal, which was inversely related to the kanamycin concentration. The detection limit of the proposed assay decreased to 59 nM with a linear working range of 0.1 μM to 20 μM for kanamycin. The cross-reactivity against six other antibiotics was negligible compared with the response to kanamycin. A satisfactory recovery of kanamycin in milk samples ranged from 80.1% to 98.0%, confirming the potential of this bioassay in the measurement of kanamycin in various applications. Our results also served as a good reference for developing similar fluorescent G4-DNA-based bioassays in the future.

  17. Automated Microfluidic Droplet-Based Sample Chopper for Detection of Small Fluorescence Differences Using Lock-In Analysis.

    Science.gov (United States)

    Negou, Jean T; Avila, L Adriana; Li, Xiangpeng; Hagos, Tesfagebriel M; Easley, Christopher J

    2017-06-06

    Fluorescence is widely used for small-volume analysis and is a primary tool for on-chip detection in microfluidic devices, yet additional expertise, more elaborate optics, and phase-locked detectors are needed for ultrasensitive measurements. Recently, we designed a microfluidic analog to an optical beam chopper (μChopper) that alternated formation of picoliter volume sample and reference droplets. Without complex optics, the device negated large signal drifts (1/f noise), allowing absorbance detection in a mere 27 μm optical path. Here, we extend the μChopper concept to fluorescence detection with standard wide-field microscope optics. Precision of droplet control in the μChopper was improved by automation with pneumatic valves, allowing fluorescence measurements to be strictly phase locked at 0.04 Hz bandwidth to droplets generated at 3.50 Hz. A detection limit of 12 pM fluorescein was achieved when sampling 20 droplets, and as few as 310 zeptomoles (3.1 × 10 -19 mol) were detectable in single droplets (8.8 nL). When applied to free fatty acid (FFA) uptake in 3T3-L1 adipocytes, this μChopper permitted single-cell FFA uptake rates to be quantified at 3.5 ± 0.2 × 10 -15 mol cell -1 for the first time. Additionally, homogeneous immunoassays in droplets exhibited insulin detection limits of 9.3 nM or 190 amol (1.9 × 10 -16 mol). The combination of this novel, automated μChopper with lock-in detection provides a high-performance platform for detecting small differences with standard fluorescence optics, particularly in situations where sample volume is limited. The technique should be simple to implement into a variety of other droplet fluidics devices.

  18. Steric hindrance inhibition of strand displacement for homogeneous and signal-on fluorescence detection of human serum antibodies.

    Science.gov (United States)

    Peng, Ying; Li, Xin; Yuan, Ruo; Xiang, Yun

    2016-10-18

    Based on a new steric hindrance inhibition of the DNA strand displacement strategy, we report the design of a robust fluorescence signal-on method for homogeneous and sensitive detection of antibodies from human serum samples. Such a steric hindrance effect leads to sensitive detection of the target antibodies with a detection limit of 5.6 nM. In addition, the developed sensing approach shows high selectivity against other interference proteins and the detection of the target antibodies in human sera by this method is also verified.

  19. A detection method for Legionella spp in (cooling) water: fluorescent in situ hybridisation (FISH) on whole bacteria.

    Science.gov (United States)

    Declerck, P; Verelst, L; Duvivier, L; Van Damme, A; Ollevier, F

    2003-01-01

    Although traditional culture methods are appropriate for detection of Legionella species, such culture takes several days. Rapid detection (FISH) on whole bacteria. Water samples were filtered and the concentrated bacteria were immediately detected (without culture) with a fluorescence microscope following appropriate labelling. The detection level was very high and quantification was possible. For the detection of all Legionella spp. the probe LEG705 was used, complementary to a 16S rRNA sequence conserved in all Legionella spp. For specific detection of L. pneumophila the probe LEGPNE1 was used. This probe is designed against a variable domain of the 16S rRNA sequence from L. pneumophila. CY3 and FLUOS labels were tested and CY3 showed clearly detectable bacteria with minimum background staining. This FISH technique is very sensitive, fast, reliable and individual bacteria are easily detected.

  20. Dual color fluorescence in situ hybridization (FISH) assays for detecting Mycobacterium tuberculosis and Mycobacterium avium complexes and related pathogens in cultures

    OpenAIRE

    Shah, Jyotsna; Weltman, Helena; Narciso, Patricia; Murphy, Christina; Poruri, Akhila; Baliga, Shrikala; Sharon, Leesha; York, Mary; Cunningham, Gail; Miller, Steve; Caviedes, Luz; Gilman, Robert; Desmond, Edward; Ramasamy, Ranjan

    2017-01-01

    Two rapid dual color fluorescence in situ hybridization (FISH) assays were evaluated for detecting M. tuberculosis and related pathogens in cultures. The MN Genus-MTBC FISH assay uses an orange fluorescent probe specific for the Mycobacterium tuberculosis complex (MTBC) and a green fluorescent probe specific for the Mycobacterium and Nocardia genera (MN Genus) to detect and distinguish MTBC from other Mycobacteria and Nocardia. A complementary MTBC-MAC FISH assay uses green and orange fluores...

  1. A dual-responsive fluorescence method for the detection of clenbuterol based on BSA-protected gold nanoclusters.

    Science.gov (United States)

    Cao, Xueling; Li, Hongwei; Lian, Lili; Xu, Na; Lou, Dawei; Wu, Yuqing

    2015-04-29

    The illegal feeding of clenbuterol (CLB) to domestic animals and the potential harm of it to human health lead an urgent requirement for the efficient detection of CLB, especially in the edible meat. In this paper we reported a new fluorescence method for the detection of trace amount of CLB by using the BSA-protected gold nanoclusters (AuNCs@BSA). Under the excitation of either 280 or 500 nm the emission of AuNCs@BSA was quenched obviously by diazotized CLB, supplying a dual-responsive fluorescence method to detect CLB in aqueous solution. In addition, the linear response of the fluorescence intensity of AuNCs@BSA to diazotized CLB allowed the quantitative detection of CLB in a range of 4.0 nM-300 μM upon excitation at two wavelength, and the limit of detection for CLB was 3.0 nM upon 280 nm excitation and 1.6 nM upon 500 nm excitation, respectively. In addition, the dual-responsive mechanism of AuNCs@BSA to CLB was investigated in detail by using several CLB analogues and reference compounds. Particularly, the proposed method was successfully applied to detect CLB in pork mince and the results were validated well by HPLC, illustrating it could be used as a reliable, rapid, and cost-effective technique for the determination of CLB residues in real samples. Copyright © 2015. Published by Elsevier B.V.

  2. Development of fiber optic spectroscopy for in-vitro and in-planta detection of fluorescent proteins

    Science.gov (United States)

    Liew, Oi Wah; Chen, Jun-Wei; Asundi, Anand K.

    2001-10-01

    The objective of this project is to apply photonics technology to bio-safety management of genetically modified (GM) plants. The conventional method for screening GM plants is through selection using antibiotic resistance markers. There is public concern with such approaches and these are associated with food safety issues, escape of antibiotic resistance genes to pathogenic microorganisms and interference with antibiotic therapy. Thus, the strategy taken in this project is to replace antibiotic resistance markers with fluorescent protein markers that allow for rapid and non-invasive optical screening of genetically modified plants. In this paper, fibre optic spectroscopy was developed to detect and quantify recombinant green (EGFP) and red (DsRED) fluorescent proteins in vitro and in planta. In vitro detection was first carried out to optimize the sensitivity of the optical system. The bacterial expression vectors carrying the coding regions of EGFP and DsRED were introduced into Escherichia coli host cells and fluorescent proteins were produced following induction with IPTG. Soluble EGFP and DsRED proteins were isolated from lysed bacterial cells and serially diluted for quantitative analysis by fibre optic spectroscopy using different light sources, namely, blue LED (475 nm), tungsten halogen (350 - 1000 nm) and double frequency Nd:YAG green laser (532 nm). Fluorescence near the expected emission wavelengths could be detected up to 320X dilution for EGFP and DsRED with blue LED and 532 nm green laser, respectively, as the excitation source. Tungsten halogen was found to be unsuitable for excitation of both EGFP and DsRED. EGFP was successfully purified by size separation under non-denaturing electrophoretic conditions and quantified. The minimum concentration of EGFP detectable with blue LED excitation was 5 mg/ml. To determine the capability of spectroscopy detection in planta, transgenic potato hairy roots and whole modified plant lines expressing the

  3. Fluorescent probes for detection of picric acid explosive: A greener approach

    Energy Technology Data Exchange (ETDEWEB)

    Chakravarty, Sudesna; Gogoi, Bedanta; Sen Sarma, Neelotpal, E-mail: neelot@iasst.gov.in

    2015-09-15

    Green materials with advantages of low cost and high sensitivity are important from the perspective of human health, environment and homeland security. Herein, we have reported two cost effective modified biomaterials as fluorophores for detection of Picric acid in aqueous state. The biomaterials Scutellarin–Hispiduloside and Curcumin have been modified with green solvent glycerol for Picric acid detection in aqueous solution. The limit of detection for Picric acid by Scutellarin–Hispiduloside–glycerol and Curcumin–glycerol are 9.1×10{sup −8} M and 6.03×10{sup −8} M respectively. These luminescence based sensors have also been able to detect Picric acid in real samples with high efficiency. The fluorescence quenching efficiency of Scutellarin–Hispiduloside–glycerol has been found to be 99% while that for Curcumin–glycerol, it is 88.9% for 0.5 µM Picric acid in aqueous state. In both the cases, the quenching is governed by FRET between the fluorophore and the quencher and the FRET efficiency has been found to be 0.968 and 0.792 respectively. In addition, both the systems show excellent selectivity towards PA in presence of other nitroaromatic compounds and are also statistically accessible. The utilization of readily available cheap biomaterials without using multistep protocol for synthesis and devoid of any kind of sophisticated equipments for the processs further enhances the utility of the method. - Highlights: • Environmentally benign systems – Scutellarin, Hispiduloside and curcumin with green solvent glycerol – have been used for Picric acid sensing. • The method is simple and cost effective with a detection limit for CIG and CG found to be 9.1×10−8 M and 6.03×10−8 M of PA respectively. • Both the sensing systems were found to be highly selective for Picric acid in the presence of structurally similar compounds. • The quenching occurs by FRET between the fluorophore and the quencher and the FRET efficiency is determined

  4. Experimental Research of Reliability of Plant Stress State Detection by Laser-Induced Fluorescence Method

    Directory of Open Access Journals (Sweden)

    Yury Fedotov

    2016-01-01

    Full Text Available Experimental laboratory investigations of the laser-induced fluorescence spectra of watercress and lawn grass were conducted. The fluorescence spectra were excited by YAG:Nd laser emitting at 532 nm. It was established that the influence of stress caused by mechanical damage, overwatering, and soil pollution is manifested in changes of the spectra shapes. The mean values and confidence intervals for the ratio of two fluorescence maxima near 685 and 740 nm were estimated. It is presented that the fluorescence ratio could be considered a reliable characteristic of plant stress state.

  5. A Compact Fluorescence Lifetime Excitation-Emission Spectrometer (FLEXEMS) for Detecting Trace Organics, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Small Business Innovative Research (SBIR) effort, Leiden Measurement Technology (LMT) proposes to design and build the Fluorescence Lifetime Excitation...

  6. A Compact Fluorescence Lifetime Excitation-Emission Spectrometer (FLEXEMS) for Detecting Trace Organics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Small Business Innovative Research (SBIR) effort, Leiden Measurement Technology (LMT) proposes to design and build the Fluorescence Lifetime Excitation...

  7. Noninvasive murine glioma detection improved following photobleaching of skin PpIX fluorescence

    Science.gov (United States)

    Gibbs-Strauss, Summer L.; Davis, Scott C.; O'Hara, Julia A.; Hoopes, P. Jack; Hasan, Tayyaba; Pogue, Brian W.

    2008-02-01

    Aminolevulinic Acid (ALA) is a prodrug which can be administered to cells, animals or patients after which it is transformed via the Heme synthesis pathway into the fluorescent molecule Protoporphyrin IX (PpIX). PpIX has been shown to be useful as both a photosensitizer for photodynamic therapy (PDT) and as a fluorescence imaging contrast agent. The ALA-PpIX system not only provides contrast for fluorescence imaging but also gives information about the metabolic activity of the imaged tissue and thus could be useful for monitoring cancer therapy. In the current study skin photobleaching was examined to determine if PpIX fluorescence contrast in malignant brain tumors could be better visualized noninvasively. Red light photobleaching decreased skin PpIX fluorescence and increased the ability to noninvasively quantify PpIX fluorescence in murine gliomas, as in vivo measurements of mean PpIX fluorescence more closely matched ex vivo quantification following skin photobleaching. Three doses of blue light photobleaching (4 J/cm2, 8 J/cm2 and 12 J/cm2) were tested and determined to give similar levels of skin photobleaching as well as a similar window of decreased skin PpIX fluorescence for noninvasive fluorescence imaging following the photobleaching dose administration.

  8. In-vivo concentration ratio estimation of two fluorescent probes for early detection of Alzheimer's Disease

    Science.gov (United States)

    Harbater, Osnat; Gannot, Israel

    2015-03-01

    In-vivo measurement of the concentrations of biological compounds using fluorescence is one of the challenging biophotonic fields. These measurements are useful in diagnostic and treatment monitoring applications that use fluorescent probes which may bond to specific proteins and drugs. In some cases the relative concentration of two compounds is a sufficient biological indicator. For instance, it has been shown that the ratio between Amyloid-Beta and tau protein in the Cerebrospinal fluid (CSF) may predict the development of Alzheimer's disease (AD) several years before current diagnosis. We have previously suggested a system that could measure the concentration ratio of these two proteins in-vivo without the need to collect CSF samples. This system uses a miniature needle with an optical fiber which is coupled to a laser source and a detector. The fiber excites fluorescent probes which were injected and bond to the proteins in the CSF, and collects the fluorescence emission. Using the fluorescence intensity ratio, the concentration ratio between the proteins is estimated, and AD may be diagnosed. In this work we present the results of an in-vivo trial performed on mice. Miniature tubes containing two fluorescent probes in several concentration ratios were inserted into the mice in two locations: subcutaneously, and deeper in the abdomen. The fluorescent probes were excited and the fluorescence intensity was measured. The concentration ratios were extracted from the fluorescence intensities using a simple calibration curve. The extracted ratios are compared to the true ratios and the system's accuracy is estimated.

  9. Development of a Novel Fiber Optic Sensor Combined with a Fluorescence Turn-on Probe for Cu (II Detection

    Directory of Open Access Journals (Sweden)

    Ma J.

    2013-04-01

    Full Text Available Existing staining-based methodology for the detection of metal ions is not well suited for real-time or in situ use. This is a significant problem, given that these ions can have a considerable impact on both human health and the environment. Thus, there is growing interest and need for simple, rapid and in-situ monitoring techniques for the purpose of detecting various target analytes (e.g. heavy metals, which is of a significant importance in many fields ranging from environmental monitoring to the study of intracellular processes. Among various sensors developed, optical fiber-optic sensors (FOS, based on fluorescence, are one class of sensors that address this goal [1]. Optical fibers are ideal for environmental sensing applications because of their ability to transmit optical signals to and from the sensing region without the use of free-space optics. In this work, we present, for the first time, a simple FOS incorporating novel fluorescence turn-on mechanism [2] that could detect Cu (II as low as 10−4 M. Traditionally, fluorescence quenching or “turn-off” was used to detect Cu (II [3]. In recent years, fluorescence “turn-on” emerges as a preferable tool. The developed fiber-optic sensor has two fiber leads and one probe head. One fiber lead includes 6 fibers for He-Ne laser excitation light delivery (e-fibers. Another fiber lead has one receiving fiber (r-fiber connected to an Ocean Optics QE65000 scientific grade spectrometer, which is interrogated by a computer via USB connection. The SpectroSuite software is used to observe and to record all spectra. The probe head combines all fibers together to form a coaxial structure with the r-fiber placed in the center. The key component in the proposed fluorescent sensing system is a probe prepared by binding a receptor containing a zwitterionic chromophore (M1, through noncovalent interactions, to the fluorescent polymer (P1 resulting in quenching its emission. The sensing mechanism

  10. Probe development for detection of TERRA 1 intramolecular G-quadruplex formation using a fluorescent adenosine derivative.

    Science.gov (United States)

    Kim, In Sun; Seo, Young Jun

    2014-03-15

    We developed a probing system to detect the intramolecular G-quadruplex of telomeric repeat-containing RNA (TERRA 1). We used a fluorescent adenosine derivative rA(py) as a fluorophore and incorporated it into the dangling position of the parallel-type G-quadruplex sequence of TERRA 1. The rA(py)-modified G-quadruplex structure exhibited a strong