WorldWideScience

Sample records for gas building installations

  1. A regulatory model for conformity evaluation in natural gas building installations; Um modelo regulatorio para avaliacao da conformidade das instalacoes prediais de gas natural

    Fossa, Alberto Jose; Santos, Edmilson Moutinho dos [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia

    2008-07-01

    The challenge of the Brazilian growth needs to consider necessarily the energy arrangements, and natural gas has relevant participation in this matter. The possibility of its end use that make possible an effective adequacy of our energy matrix must be supported by modern concepts of quality and conformity. In this particular, the program of 'Tecnologia Industrial Basica' (TIB), including concepts and application of conformity evaluation processes, is considered basic for the construction of a consistent gas market. This paper present the Brazilian reality related to TIB aspects and elements, from which it constructs a technician and regulatory building gas installations model proposal for a conformity evaluation program in the country. (author)

  2. Poultry farming buildings. Natural gas heating. Guidebook of installation rules; Batiments d`elevage avicole. Chauffage au gaz. Guide des regles d`installation

    NONE

    1997-12-31

    The technical and economical performances of a poultry farm are greatly influenced by the mastery of ambient temperature during the first days of husbandry. The natural gas space heating installation must answer these requirements and also respect all safety rules concerning the personnel and the animals. In order to answer the questions of poultry farming professionals, the technical association of the natural gas industry (ATG) in France and the Groupama insurance company have redefined the new version of this brochure which integrates the recent technological advances and defines the minimum quality and safety rules required to achieve a natural gas heating installation. The different topics presented are: the gas supply (aerial fixed reservoirs), the general distribution panel (location, command systems, regulation systems for LPG installations, electrical equipments), the distribution pipes (general supply, indoor pipes, flexible pipes, pipe fittings), the heating systems (power, choice, power supply, fastening, air renewal), the check and sign and the start-up of the installation, the periodical control and maintenance operations. (J.S.)

  3. Planning of installations in prefabricated buildings

    Stanojević Ana D.

    2014-01-01

    Full Text Available Planning installations is becoming an increasing problem in construction, because the number of devices for technical supply is constantly increasing with continual progress in science and technology. Since the installations of the building can not be viewed unrelated of the construction, problem of its planning is more complicated in prefabricated buildings because the elements of construction are prefabricated. Planning was formerly performed by embedding the installation in prefabricated elements. This method had a lot of flaws, and modern approach tends setting installation out of prefabricated elements except when the traditional approach proves as economical. Although the hot water heating with radiators is the most practical way of heating in prefabricated buildings, the under floor heating systems have greater and greater use. Today, prefabricated sanitary cabins have a huge use and they are much more economical in comparison to special panels for bathrooms that were once create. Approaches in terms of planning electrical installation are different, but for conventional constructed buildings, as well as prefabricated buildings, the use of lightweight prefabricated walls with embedded installations, today is recommended, when the room is loaded with a large number of this installations and if it is possible.

  4. Tolley's industrial and commercial gas installation practice

    Hazlehurst, John

    2010-01-01

    This is the third of three essential reference volumes for those concerned with the installation and servicing of domestic and industrial gas equipment. This volume explains the basic principles underlying the practical and theoretical aspects of installing and servicing gas appliances and associated equipment, from the basics of combustion, to burners, pressure and flow, transfer of heat, controls, as well as materials and processes, electrical aspects, and metering and measuring devices. Covering both Natural Gas and Liquefied Petroleum Gas, the many illustrations and worked examples include

  5. Natural gas fuelling stations installation code

    Barrigar, C; Burford, G; Adragna, M; Hawryn, S

    2004-07-01

    This Canadian Standard applies to natural gas fuelling stations that can be used for fleet and public dispensing operations. This document is divided into 11 sections that address the scope of the Standard; definitions and reference publications; general requirements; compressors; storage; dispensing; flow control devices; storage vessel dispatch and receiving; design, installation and testing of piping, tubing and fittings; and installation of vehicle refuelling appliances (VRAs) connected to storage piping. The most recent revision to the Standard includes requirements for indoor fuelling of natural gas vehicles. This Standard, like all Canadian Standards, was subject to periodic review and was most recently reaffirmed in 2004. tabs., figs.

  6. Gas heat pump installation at Paderborn

    1978-01-01

    A gas heat pump installation at the swimming pool and sport center in Paderborn, developed by Ruhrgas A.G. has a heat capacity of 4650 kW, the largest up to this time and recovers heat from ground water under the sport center, shower, and swimming pool effluent, and air exhausted from the swimming pool to provide 182% of the energy obtained from the natural gas alone. This compares with an 80% efficiency for a conventional boiler fired with natural gas. Natural gas consumption by the sport center has been reduced from 1.2 million m/sup 3/ y to 520,000 m/sup 3//y, a 56% savings. Three identical units each have an eight-cylinder, four-cycle, 253 kW-gas engine.

  7. RA reactor building and installations; Zgrada 'RA' i instalacije

    Badrljica, R; Sanovic, V; Skoric, M [Institute of Nuclear Sciences Boris Kidric, Vinca, Beograd (Serbia and Montenegro)

    1985-08-15

    RA reactor building is made of reinforced concrete and bricks. It is closed facility with a limited number of controlled openings, doors and windows. The site of the building is 100 m above the sea level, 20 m above the mean Danube level and 8 m above the level of the neighbouring stream Mlaka. The building consists of three parts: central prismatic part, annex - surrounding the central part and the sanitary corridor. The biggest space is the reactor hall. In addition to the detailed description and drawings of the reactor building this documents includes design specifications of: electrical installation, water supply system, sewage system, ventilation and heating, gas and compressed air systems. A separate chapter is devoted to fire protection. Zgrada reaktora RA izgradjena je od armiranog betona i opeke, kao zatvoreni objekat ogranicenog broja kontolisanih otvora, sa ogranicenim brojem vrata i prozora. Plato na kojem je zgrada izgradjena nalazi se na 100 m nadmorske visine, na 20 m iznad srednjeg vodostaja Dunava i 8 m iznad nivoa obliznjeg potoka Mlaka. Zgrada se sastoji iz tri dela: sredisnjeg prizmaticnog dela, aneksa - prstenastog okvira sredisnog dela i sanitarnog propusnika. Pojedinacno najveci prostor zauzima reaktorska hala. Pored detaljnog opisa i plana zgrade, ovaj dokument sadrzi projekat elektricne instalacije, projekat vodovoda i kanalizacije, ventilacije i grejanja, instalacije gasa i komprimovanog vazduha. Posebno poglavlje posveceno je protivpozarnoj zastiti.

  8. Development of a unified sizing method for gas radiation heating facilities used in large-volume buildings; Developpement d'une methode de dimensionnement unifiee d'installations de chauffage radiant gaz pour les batiments de grand volume

    Jimenez, M.; Bego, L.; Douls, Y.; Le Dean, P.; Paradowski, V. [Gaz de France, GDF, Dir. de la Recherche, 75 - Paris (France)

    2000-07-01

    Builders now have perfect command of the natural gas heating technique used for large-volume buildings. However, the sizing of heating facilities still leaves grounds for discussion, whatever the energies actually used. Accordingly, between 1997 and 1999, the ATG (technical association of the Gas industry in France), seven French manufacturers of 'large volume' heating equipment, the Chaleur Et Rayonnement (CER) association and Gaz de France decided to collaborate and develop a 'unified sizing method' for heating facilities using radiating emitters. During the first year of the study, the above partners worked on the said method (theoretical thermal study of the radiative phenomena, and then adaptation to the methods currently used by the various manufacturers). In 1998, with the support of the ADEME (the French environment and energy control agency), the partners tested the method on five industrial buildings (studying the thermal behavior and making air renewal measurements with search gases). This work made it possible to either confirm or adapt the theoretical evaluations which had been made originally. In 1999, a software program was produced to make the developed method more user friendly. The program can be used to determine the power to be installed, but also to assess the quality of the chosen configuration of the emitters (unit power, inclination, orientation) for optimum customer comfort. (authors)

  9. Small wind planning and building successful installations

    Clark, Nolan

    2013-01-01

    This book provides a cohesive guide to achieving successful small wind installations. It is a comprehensive information resource from one of the world's most experienced small wind professionals, covering all the key issues for small wind system development, from site and machine selection to international standards compliance. Engineers who are tasked with planning and developing these small wind systems, from choosing the best site and accurately estimating likely power output to obtaining proper permitting and troubleshooting operational inefficiencies, will find this book an ess

  10. Design/Installation and Structural Integrity Assessment of Bethel Valley Low-Level Waste collection and transfer system upgrade for Building 3092 (central off-gas scrubber facility) at Oak Ridge National Laboratory

    1994-10-01

    This document describes and assesses planned modifications to be made to the Building 3092 Central Off-Gas Scrubber Facility of the Oak Ridge National Laboratory, Oak Ridge, Tennessee. The modifications are made in response to the requirements of 40CFR264 Subpart J, relating to environmental protection requirements for buried tank systems. The modifications include the provision of a new scrubber recirculation tank in a new, below ground, lined concrete vault, replacing an existing recirculation sump that does not provide double containment. A new buried, double contained pipeline is provided to permit discharge of spent scrubber recirculation fluid to the Central Waste Collection Header. The new vault, tank, and discharge line are provided with leak detection and provisions to remove accumulated liquid. Ne scrubber recirculation pumps, piping, and accessories are also provided. This assessment concludes that the planned modifications comply with applicable requirements of 40CFR264 Subpart J, as set forth in Appendix F to the Federal Facility Agreement, Docket No. 89-04-FF, covering the Oak Ridge Reservation. A formal design certification statement is included herein on Page 53, a certification covering the installation shall be executed prior to placing the modified facility into service

  11. The role of installers for thermo-technical installations when buying gas boilers

    Jovičić Dragoljub

    2013-01-01

    Full Text Available This study presents the research of role installers for thermo-technical installations when buying gas boilers in the Serbian market. Considering the fact that installers are significantly different, they are grouped by specific, relevant characteristics. The research is focused on the evaluation of marketing mix instruments by nine identified segments of installers. Moreover, research has been explored deeper through conclusion installers about the most important and most credible sources of information on gas boilers. During the research were used secondary and primary data sources. Besides the research at the table, field research has been also done by unstructured personal communication. All collected data were analyzed in details and both hypothesis were tested, where one of them is partially confirmed, and another one fully confirm. Given results can be useful for marketers and their anticipation of demand. Also these results can be used for creating optimal marketing strategy in the Serbian market of gas boilers.

  12. Regulations concerning the cooking installations using the natural gas in the bakeries and the cake shops of the shopping Centers; Reglementation des installations de cuisson au gaz naturel en boulangerie-patisserie dans les centres commerciaux

    NONE

    2001-05-01

    This brochure presents the regulation relative to the cooking installations using the natural gas in bakeries and cake shops of the shopping Centers. Following the general regulation context, the guide presents the ovens which can be installed and the associated technical restraints. The necessary conditions for the buildings, the gas alimentation, the natural gas pipelines in the buildings and the installations conditions are also presented. Finally the guide presents the maintenance facilities obligations. (A.L.B.)

  13. Evaluation Of RSG-GAS Power Installed After 12 Years

    Mrsahala, Yan Bony

    2001-01-01

    The total power installed in RSG-GAS electric system less then 3 x 2500 KVA. Some of powers installed included are the never used loads, so the operationally total load installed that regularly operational and incidental are amount about 3700 KVA. In this condition, the capacity of power transformer installed 3 x 2500 KVA becomes larger. The influences of the numinous power are electric bill payment by RSG-GAS. The reduces power installed may be done as well as remember that some of the load not be operation so that the power consume for that facility could be cut off. The evaluation and calculation result gives some alternatively can be selected to minimize the electric bill payment

  14. Decommissioning of offshore oil and gas installations

    Day, M.D.; Marks, M.H.

    1997-01-01

    A task facing the offshore oil and gas industry is the removal of about 7000 platforms. In this chapter, the legal framework for offshore platform decommissioning is first discussed. The various phases of abandonment are then described. The first and most critical of these is the planning phase which should be initiated years in advance when depletion plans for a field are recommended. Seven discrete activities are identified in the abandonment process itself and briefly discussed. These are: the permanent plugging and abandonment of non-productive well bores; pre-abandonment surveys and data gathering to gain knowledge about the platform and its condition; decommissioning; structure removal; disposal, recycle or reuse of platform components on or off shore; site clearance. (13 figures; 13 references) (UK)

  15. Investigation on Prefabricated Building System Skilled Component Installers

    Nurul Rezuana Buyung

    2013-09-01

    Full Text Available In the face of an increasingly challenging era of globalization, skills and new equipments which includes prefabricated building components, known as Industrialized Building System (IBS has been introduced towards achievement of sustainable construction. IBS is a construction system in which the components are manufactured in a factory, on or off site, positioned and assembled into complete structures with minimal additional site work. IBS requires high construction precision and needs a higher skill level of workers. Compared to the conventional construction method, the skill level of IBS workers is more demanding. Although there are a lot benefits in implementing IBS, the construction industry still not rapidly implementing IBS. The IBS method still considered new and even though there are a lot of benefits it still faces barriers. In an IBS construction, the role of the contractor is shifted from a builder to an assembler on the site. Therefore, this requires the contractor to be prepared technologically with IBS knowledge and skills. It is generally perceived that the number of skilled IBS installers in Malaysia is still low even though the system has been implemented for a long time. This research is carried out to find out whether the existing number of IBS installer is sufficient. Primary data was collected by carrying out interviews with the contractors at the IBS construction site in Penang Island in order to get the contractor’s feedback regarding this issue. Meanwhile, the secondary data was collected from government agencies to get the number of existing IBS installer and the number of IBS projects done in government projects. The results from this study indicated that not all categories of skill workers are in shortage. However, the number of precast concrete installer is in a critical shortage.

  16. MANAGEMENT OF GAS-AIR ENERGY INSTALLATION OF INDUSTRIAL ENTERPRISE

    V. Y. Lobov

    2018-02-01

    Full Text Available Purpose. The goal of the work is to substantiate the issue of effective use of kinetic energy of gas-air flows used by the technological installation for generating electric power, which will allow developing a new control algorithm and creating new software for controlling the gas-air power plant. To test the adequacy of the developed control algorithms and software, to develop a laboratory gas-air power plant. Methodology. To investigate the distribution of air-gas mass in process plants used industrial plant simulation method performed in software SolidWorks Flow Simulation. The method of simulation allowed to develop a new control algorithm and create new software taking into account the basic technical requirements for the management of the gas-air power plant. To test the efficiency of the developed algorithms and control software for the gas-air power plant, a physical modeling method was used on a developed laboratory installation connected via a USB interface with a computer and has a virtual model of the SCADA system presented in the LabVIEW environment. Findings. Based on the modeling of gas-air flows on the developed mathematical model, the optimal ratios of pipeline sizes are rationally determined, the gas-air mixture costs necessary for the most efficient operation of the gas-air power plant, that is, in the working zone of the gas-air path, the generator screw contacts the most significant flows, providing the maximum effect rotation. The obtained results of research of gas-air flows of technological installations of an industrial enterprise in the software environment of SolidWorks Flow Simulation and on their basis the basic technical requirements for the management of a gas-air power plant are developed. An optimal control algorithm has been developed that enabled it to be introduced into the control scheme of a gas-air power plant with a microprocessor or a specialized microcontroller. Originality. New possibilities for

  17. Gas turbine installations in nuclear power plants in Sweden

    Sevestedt, Lars [Electrical Equipment and Gas Turbines, Swedish State Power Board, Ringhals Nuclear Power Plant, S-430 22 Vaeroebacka (Sweden)

    1986-02-15

    At each of the four nuclear power stations in Sweden (Ringhals, Forsmark, Oskarshamn, Barsebaeck) gas turbine generating sets have been installed. These units are normally used for peak load operation dictated of grid and System requirements but they are also connected to supply the electrical auxiliary load of the nuclear plant as reserve power sources. The gas turbines have automatic start capability under certain abnormal conditions (such as reactor trips, low frequency grid etc) but they can also be started manually from several different locations. Starting time is approximately 2- 3 minutes from start up to full load. (author)

  18. Gas turbine installations in nuclear power plants in Sweden

    Sevestedt, Lars

    1986-01-01

    At each of the four nuclear power stations in Sweden (Ringhals, Forsmark, Oskarshamn, Barsebaeck) gas turbine generating sets have been installed. These units are normally used for peak load operation dictated of grid and System requirements but they are also connected to supply the electrical auxiliary load of the nuclear plant as reserve power sources. The gas turbines have automatic start capability under certain abnormal conditions (such as reactor trips, low frequency grid etc) but they can also be started manually from several different locations. Starting time is approximately 2- 3 minutes from start up to full load. (author)

  19. Installation for gas purification and gas mixture preparation

    Ciortea, Constantin; Dumitrescu, Ioana; Armeanu, Adrian

    2002-01-01

    The Gas Production Division of ICSI at Rm. Valcea developed advanced facilities for purification of hydrogen, nitrogen, methane gases, etc, with concentrations up to 99.999 % vol. Pure and ultrapure gases are used for analytical purposes in food industry, biology, medicine, research laboratories, chemical and metallurgical industries. In the frame of ICSI the purified gases are used for preparation of usual and special mixtures of gases as for instance for production of Ar + CO 2 , Ar + CH 4 , Ar + H 2 , Ar + N 2 , N 2 + CO 2 , N 2 + O 2 etc. These mixtures are required in diverse sectors of chemical, electrical, machine and food industry, in nuclear power plants for monitoring, in laboratories of equipment calibrations, etc. (authors)

  20. Design/installation and structural integrity assessment of Bethel Valley low-level waste collection and transfer system upgrade for Building 3092 (Central Off-Gas Scrubber Facility) at Oak Ridge National Laboratory

    1995-01-01

    This document describes and assesses planned modifications to be made to the Building 3092 Central Off-Gas Scrubber Facility of the Oak Ridge National Laboratory, Oak Ridge, Tennessee. The modifications are made in responsible to the requirements of 40CFR264 Subpart J, relating to environmental protection requirements for buried tank systems. The modifications include the provision of a new scrubber recirculation tank in a new, below ground, lines concrete vault, replacing and existing recirculation sump that does not provide double containment. A new buried, double contained pipeline is provided to permit discharge of spent scrubber recirculation fluid to the Central Waste Collection Header. The new vault, tank, and discharge line are provided with leak detection and provisions to remove accumulated liquid. New scrubber recirculation pumps, piping, and accessories are also provided. This assessment concludes that the planned modifications comply with applicable requirements of 40CFR264 Subpart J, as set forth in Appendix F to the Federal Facility Agreement, Docket No. 89-04-FF, covering the Oak Ridge Reservation

  1. Electro magnetic compatibility of cabling and wiring in buildings and installations

    Steenstra, H.T.

    2008-01-01

    The thesis deals with the behaviour, with respect to EMC (Electro Magnetic Compatibility), of cabling and wiring in buildings and installations. Measurement and calculation methods are developed and applied to cabling in a large scale installation as well as to individual cables. Besides, the location and interconnection of conductors, especially concrete reinforcement, in a building is investigated. Finally a procedure is developed that is used to deal with EMC issues in a large installation...

  2. Solar heating, cooling and domestic hot water system installed at Columbia Gas System Service Corporation, Columbus, Ohio

    1980-01-01

    The solar energy system installed in the building has 2,978 sq ft of single axis tracking, concentrating collectors and provides solar energy for space heating, space cooling and domestic hot water. A 1,200,000 Btu/hour water tube gas boiler provides hot water for space heating. Space cooling is provided by a 100 ton hot water fired absorption chiller. Domestic hot water heating is provided by a 50 gallon natural gas domestic storage water heater. Extracts from the site files, specification references, drawings, installation, operation and maintenance instructions are included.

  3. Operation and maintenance of the technical installations in buildings

    Nielsen, O.(red.)

    The report contains twelve papers from a seminar on operation and maintenance, held at the Danish Building Research Institute in October 1976. The papers deal, among other things, with dimensioning and balancing of pipesystems, design of ventilating systems for adequate operation and maintenance,......, cost and quality in maintenance, maintenance service companies, as well as organization and training for building services maintenance....

  4. RFAR installation for Buildings 703, 712, 747, 748 and 1163

    Ferry, M.

    1995-01-01

    This document is to certify the installation and testing of the Radio Fire Alarm Reporting box (RFAR). The Hanford Fire Dept. will be notified of troubles via RFAR. The document outlines prerequisites, necessary equipment, and the fire alarm system test to insure the system is operating correctly

  5. Investigation on Prefabricated Building System Skilled Component Installers

    Nurul Rezuana Buyung; Md Azree Othuman Mydin; Abdul Naser Abdul Ghani

    2013-01-01

    In the face of an increasingly challenging era of globalization, skills and new equipments which includes prefabricated building components, known as Industrialized Building System (IBS) has been introduced towards achievement of sustainable construction. IBS is a construction system in which the components are manufactured in a factory, on or off site, positioned and assembled into complete structures with minimal additional site work. IBS requires high construction precisi...

  6. Electro magnetic compatibility of cabling and wiring in buildings and installations

    Steenstra, H.T.

    2008-01-01

    The thesis deals with the behaviour, with respect to EMC (Electro Magnetic Compatibility), of cabling and wiring in buildings and installations. Measurement and calculation methods are developed and applied to cabling in a large scale installation as well as to individual cables. Besides, the

  7. Escalation scenarios initiated by gas explosions on offshore installations. Probabilistic cause and consequence modelling

    Eknes, Monika Loeland

    1996-12-31

    This Dr. ing. thesis deals with escalation scenarios initiated by gas explosions on offshore installations. Gas explosions is one of the major hazards to such installations. The objectives were to estimate the probability of ignition and frequency of gas explosions for gas leaks on top sides of offshore installations, and to estimate the response and resistance of components that could result in escalation if they failed. Main fields considered cover risk analysis methodology, gas explosions, simplified escalation models, evaluation of structural consequences, case studies, and guidelines. 107 refs., 33 figs., 33 tabs.

  8. A new gas stripper system for BARC-TIFR Pelletron Accelerator facility: installation and preliminary results

    Sharma, S.C.; Ninawe, N.G.; Yadav, M.L.; Ekambaram, M.; Ramjilal; Matkar, U.V.; Ansari, Q.N.; Lokare, R.N.; Ramlal; Gupta, A.K.; Bhagwat, P.V.; Pillay, R.G.

    2009-01-01

    The gas-stripper plays a key role in stripping the heavy and molecular ion beams in a tandem accelerator. Efficiency of gas stripper depends on its supporting vacuum pumps. A new recirculating turbo molecular pump-based gas stripper has been installed in the high voltage terminal of Pelletron Accelerator. Re-circulating the stripper gas reduces the flow of gas into the accelerating tubes reducing the transmission losses. Preliminary results obtained using the new gas stripper system are discussed. (author)

  9. Improved gas installations and services. Phase 1: Analysis project. Part report

    Nielsen, K.J.

    1996-05-01

    As Danish gas companies receive a large number of complaints related to the installation and operation of gas installations it was suggested that a course for personnel should be established in order to raise the standard of services and installation requirements. The first phase of the described project was to evaluate the quality of the gas installers' services so as to determine which aspects of installation and services should be emphasized during such a course. Interviews were carried out and questionnaires (illustrated within the document) sent out to installaters etc. Recommendations include that the level of information given to customers should be raised, also in relation to maintenance, and that installation should be improved. Analyses of the degree of customers' satisfaction, of the nature of the quality of services etc. expected, subjects for further training in this area and details of the training system are dealt with

  10. Analysis of Installed Measures and Energy Savings for Single-Family Residential Better Buildings Projects

    Heaney, M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Polly, B. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-04-30

    This report presents an analysis of data for residential single-family projects reported by 37 organizations that were awarded federal financial assistance (cooperative agreements or grants) by the U.S. Department of Energy’s Better Buildings Neighborhood Program.1 The report characterizes the energy-efficiency measures installed for single-family residential projects and analyzes energy savings and savings prediction accuracy for measures installed in a subset of those projects.

  11. Building system technology with installation bus. Planning now for the future; Gebaeudesystemtechnik - mit Installationsbus. Heute schon an morgen denken

    Vogt, D. [RWE Energie AG, Essen (Germany)

    1995-12-31

    In chapter 16 of the anthology about building technology the building system technology with installation bus is described. The following aspects are discussed: limits of the conventional electric installation, building system technology, building system technology - illusion or reality?; The European Installation Bus Association (EIBA). (BWI) [Deutsch] Kapitel 16 des Sammelbandes ueber Building Control ist dem Thema der Gebaeudesystemtechnik mit Installationsbus gewidmet. In diesem Zusammenhang werden folgende Themenbereiche angesprochen: Grenzen der konventionellen Elektroinstallation; Gebaeudesystemtechnik; Gebaeudesystemtechnik - Illusion oder Realitaet?; Die EIBA (European Installation Bus Association). (BWI)

  12. Large-scale building integrated photovoltaics field trial. First technical report - installation phase

    NONE

    2004-07-01

    This report summarises the results of the first eighteen months of the Large-Scale Building Integrated Photovoltaic Field Trial focussing on technical aspects. The project aims included increasing awareness and application of the technology, raising the UK capabilities in application of the technology, and assessing the potential for building integrated photovoltaics (BIPV). Details are given of technology choices; project organisation, cost, and status; and the evaluation criteria. Installations of BIPV described include University buildings, commercial centres, and a sports stadium, wildlife park, church hall, and district council building. Lessons learnt are discussed, and a further report covering monitoring aspects is planned.

  13. Behavior in exploitation of gas-lift installations with differential valves. Pt. 2

    Bodea, I; Truica, V

    1969-07-01

    In this second installment, charts of casing and tubing pressure are shown to illustrate how they can be used as diagnostic tools, both for continuous and intermittent gas-lift installations. The desirable conditions for continuous gas lift are constant casing and tubing pressures; for intermittent gas lift, cycles of equal length and intensity. After discussion of the possible flow regimes in the production tubing, it is shown that pressure gradient and temperature measurements can also be used as diagnostic tools. The basic rules for designing a continuous flow gas-lift installation by multipoint injection are given. Application of these principles in several wells has resulted in an increase in the oil production rate, a decrease in the gas requirement, and a reduction in the frequency of well pulling jobs. A well-designed installation can be expected to function trouble- free for 2 to 4 yr.

  14. Teachers' and Students' Perception of Instructional Supervision on Capacity Building in Electrical Installation Trade

    Eze, Ogwa Christopher

    2015-01-01

    This research was conducted to ascertain teachers' and students perception of instructional supervision in relation to capacity building in electrical installation trade in technical colleges. Three research questions and a null hypothesis were employed to guide the study. Descriptive survey was adopted. A 23-item questionnaire was used to elicit…

  15. Installation of the Ferranti Mercury computer in building 2 on 30 June 1958

    1958-01-01

    The Ferranti Mercury was CERN's first "central" computer. It was installed in building 2 on 30 June 1958. The Mercury's performance did not compare to the simplest of today's pocket calculators. Its clock speed was a modest 1 MHz and its RAM capacity was 2000 20-bit words.

  16. Solar heating and cooling of residential buildings: sizing, installation and operation of systems. 1980 edition

    None

    1980-09-01

    This manual was prepared as a text for a training course on solar heating and cooling of residential buildings. The course and text are directed toward sizing, installation, operation, and maintenance of solar systems for space heating and hot water supply, and solar cooling is treated only briefly. (MHR)

  17. Low-voltage electrical installations in medical buildings - clinical centres and hospitals

    Simić Ninoslav

    2015-01-01

    Full Text Available This paper presents the observations collected during the testing of electrical installations in medical buildings. The details of the power supply, wiring systems and the implemented systems of protection against electric shocks are described. The causes of some faults during the exploitation of the facilities are presented through practical examples, and the specific problem caused by water leaking through the insulation of electrical installations is explained in detail. It is pointed out how important maintenance, monitoring and application of the latest standards in this area are, as well as adequate training of professional staff.

  18. Study for North-Baranja gas network installation

    Anders, S.; Komornoki, L.

    1999-01-01

    The public administration in Osijecko-Baranjska County in East Slavonia strives for ensuring gas supply for the North Baranja region as part of the regional reconstruction program. MOL Co., Ruhrgas AG., and WGV Co. and Partners have declared their willingness to explore and study the opportunities of gas supply in North Baranja in Croatia. In this context, the three partners have jointly prepared a feasibility study. The study contains four sections: the first briefly outlines the present status in North Baranja and describes the methods of preparing natural gas consumption forecasts. The second section addresses issues related to the dimensioning of the high pressure system transporting gas from Hungary into North Baranja in Croatia, and the required capital expenditures. The third section presents the concept of technical design and engineering, the time planned for implementation as well as capital expenditures for the distribution system. The fourth section introduces the method and results of the profitability analysis. Natural gas consumption in North Baranja is estimated as 20 mcm by 2010. The basic assumption for technical dimensioning the natural gas transmission system, of the region is that the following system components will need to be constructed: 23 km long (PN 25) high pressure system, and 143 km long (PN; 4 bar) medium pressure system, finally 287 km distribution system in cities/ villages. Total capital expenditures for constructing the distribution network are MDEM 32,5 (using 1998 cost levels), according to the study. Of that, the share of the high pressure system will be 20%, the medium pressure system 28,3% and the local distribution network 51,7% (including connections of houses). To prepare the profitability analysis for natural gas supply of North Baranja we used the method of planning a nominal profit statement, balance sheet and cash flow up to 2013. The profitability analysis followed the four options developed for natural gas supply

  19. 46 CFR 58.10-15 - Gas turbine installations.

    2010-10-01

    ... applicable, shall be furnished. (c) Exhausts. (1) Where piping is used for gas turbine exhaust lines, Class II is required as a minimum. (See subpart 56.04 of this subchapter.) Where the exhaust pressure... other than pipe is employed, the drawings and design data shall be submitted to substantiate suitability...

  20. Bacterial community structures in air conditioners installed in Japanese residential buildings.

    Hatayama, Kouta; Oikawa, Yurika; Ito, Hiroyuki

    2018-01-01

    The bacterial community structures in four Japanese split-type air conditioners were analyzed using a next-generation sequencer. A variety of bacteria were detected in the air filter of an air conditioner installed on the first floor. In the evaporator of this air conditioner, bacteria belonging to the genus Methylobacterium, or the family of Sphingomonadaceae, were predominantly detected. On the other hand, the majority of bacteria detected in the air filters and evaporators of air conditioners installed on the fifth and twelfth floors belonged to the family Enterobacteriaceae. The source of bacteria belonging to the family Enterobacteriaceae may have been aerosols generated by toilet flushing in the buildings. Our results suggested the possibility that the bacterial contamination in the air conditioners was affected by the floor level on which they were installed. The air conditioner installed on the lower floor, near the ground, may have been contaminated by a variety of outdoor bacteria, whereas the air conditioners installed on floors more distant from the ground may have been less contaminated by outdoor bacteria. However, these suppositions may apply only to the specific split-type air conditioners that we analyzed, because our sample size was small.

  1. Technology keeps ice away from offshore oil and gas installations

    Anon

    2003-05-01

    Ice management services provided to oil and natural gas operators off Canada's North Atlantic coast by Provincial Airlines is described. Provincial Airlines performs iceberg reconnaissance for both the offshore oil and natural gas operators as well as for the Canadian Ice Centre, using its specially equipped B-200 aircraft. The special equipment includes a complete electronic sensor package with 360-degree anti-submarine warfare radar, a thermal imaging system, high powered gyro-stabilized TV camera system, and a computerized data collection and management system. The Ice Data Network System (IDNS) is a fifth generation computer software package designed to monitor ice, provide drift analysis and forecast future trajectories, assess potential threats or risks associated with each piece of ice, and monitor and evaluate towing operations if required. The IDNS is backed up by a fully staffed ice operations centre from which Provincial Airline ice specialists can access satellite data and reports on ice conditions from around the world. Using a process of data fusion and careful analysis, staff of the Ice Centre can produce near-real time reports that depict ice conditions specific to individual operational requirements. Since drilling platforms cannot move, or require a great deal of time to move, to avoid any risk of an iceberg colliding with an oil platform it is important to know where exactly an iceberg is at any given time, hence the enormous importance of iceberg location information.

  2. Low frequency noise and air vibration generated by a simple cycle gas turbine installation

    Giesbrecht, C.; Hertil, S. [ATCO Noise Management, Calgary, AB (Canada)

    2005-07-01

    Low-frequency noise refers to infrasound whose frequency is lower than the minimum human audible frequency of about 20 Hz. Recently, there have been serious complaints on noise pollution in the frequency range of 1-100 Hz. This presentation outlined ASHRAE noise criteria regions and discussed human perceptions to vibration. It also presented methods that ATCO used for measuring noise at a simple gas turbine installation, inside the site at the administration buildings, at the paths of vibration and noise propagation, and at noise sensitive receptors. A 70 dBC at the closes noise-sensitive receptor was used as a noise limit to minimize annoyance. In addition, 96 dBC was measured at 400 feet. It was noted that reducing the C-weighted sound level depends on reducing the stack noise emissions in the 16 and 31.5 band levels. ATCO evaluated silencer designs and recommended reactive silencers to achieve a 10 dB reduction in noise emitted by the 3 exhaust stacks. 6 figs.

  3. Decree 368/013 To grant to Resume Gas S A the concession to build and operate the pipeline linking the re gasification terminal Puntas de Sayago with Southern Cross Pipeline

    2013-01-01

    Terminal project to be installed in the Resume Tips by Resume Gas S A under Boot mode (Build, Operate, Own, Transfer) in order to receive liquefied natural gas, re gasify and injecting it into the transmission network in the country

  4. 78 FR 56944 - Pacific Gas and Electric Company; Humboldt Bay Independent Spent Fuel Storage Installation

    2013-09-16

    ... process waste at the Humboldt Bay ISFSI will not significantly affect the quality of the human environment... NUCLEAR REGULATORY COMMISSION [Docket No. 72-27; NRC-2011-0115] Pacific Gas and Electric Company; Humboldt Bay Independent Spent Fuel Storage Installation AGENCY: Nuclear Regulatory Commission. ACTION...

  5. Solar heating and hot water system installed at Municipal Building complex, Abbeville, South Carolina

    1979-01-01

    Information on the solar energy system installed at the new municipal building for the City of Abbeville, SC is presented, including a description of solar energy system and buildings, lessons learned, and recommendations. The solar space heating system is a direct air heating system. The flat roof collector panel was sized to provide 75% of the heating requirement based on an average day in January. The collectors used are job-built with two layers of filon corrugated fiberglass FRP panels cross lapped make up the cover. The storage consists of a pit filled with washed 3/4 in - 1 1/2 in diameter crushed granite stone. The air handler includes the air handling mechanism, motorized dampers, air circulating blower, sensors, control relays and mode control unit. Solar heating of water is provided only those times when the hot air in the collector is exhausted to the outside.

  6. Installation of laboratory scale flue gas treatment system at ALURTRON, MINT

    Siti A'iasah Hashim; Khairul Zaman Dahlan; Zulkafli Ghazali; Khomsaton Abu Bakar, Ayub Muhamad

    2002-01-01

    A laboratory scale test rig to treat simulated flue gas using electron beam technology was installed at the Alurtron EB-irradiation center, MINT. The experiment test rig was proposed as a result of a feasibility studies conducted jointly by IAEA, MINT and TNB Research in 1997. The test rig system consisted of several components, among other, diesel generator, gas analyzers and spray cooler. The installation was completed and commissioned in October 2001. Results from the commissioning test runs and subsequent experimental work showed that the efficiency of the gas treatment is high. It was proven that electron beam technology might be applied in the treatment of air pollutants. This paper describes the design and work function of the individual major components as well as the full system function. Results from the initial experimental works are also presented. (Author)

  7. Optimum Installation of Sorptive Building Materials Using Contribution Ratio of Pollution Source for Improvement of Indoor Air Quality.

    Park, Seonghyun; Seo, Janghoo

    2016-04-01

    Reinforcing the insulation and airtightness of buildings and the use of building materials containing new chemical substances have caused indoor air quality problems. Use of sorptive building materials along with removal of pollutants, constant ventilation, bake-out, etc. are gaining attention in Korea and Japan as methods for improving such indoor air quality problems. On the other hand, sorptive building materials are considered a passive method of reducing the concentration of pollutants, and their application should be reviewed in the early stages. Thus, in this research, activated carbon was prepared as a sorptive building material. Then, computational fluid dynamics (CFD) was conducted, and a method for optimal installation of sorptive building materials was derived according to the indoor environment using the contribution ratio of pollution source (CRP) index. The results show that a method for optimal installation of sorptive building materials can be derived by predicting the contribution ratio of pollutant sources according to the CRP index.

  8. Cooling performance of a vertical ground-coupled heat pump system installed in a school building

    Hwang, Yujin; Lee, Jae-Keun; Jeong, Young-Man; Koo, Kyung-Min [Department of Mechanical Engineering, Pusan National University, San 30, Jangjeon-Dong, Kumjung-Ku, Busan 609-735 (Korea); Lee, Dong-Hyuk; Kim, In-Kyu; Jin, Sim-Won [LG Electronics, 391-2 Gaeumjeong-dong, Changwon City, Gyeongnam (Korea); Kim, Soo H. [Department of Nanosystems and Nanoprocess Engineering, Pusan National University, San 30, Jangjeon-Dong, Kumjung-Ku, Busan 609-735 (Korea)

    2009-03-15

    This paper presents the cooling performance of a water-to-refrigerant type ground heat source heat pump system (GSHP) installed in a school building in Korea. The evaluation of the cooling performance has been conducted under the actual operation of GSHP system in the summer of year 2007. Ten heat pump units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. To analyze the cooling performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the cooling capacity and the input power were evaluated to determine the cooling performance of the GSHP system. The average cooling coefficient of performance (COP) and overall COP of the GSHP system were found to be {proportional_to}8.3 and {proportional_to}5.9 at 65% partial load condition, respectively. While the air source heat pump (ASHP) system, which has the same capacity with the GSHP system, was found to have the average COP of {proportional_to}3.9 and overall COP of {proportional_to}3.4, implying that the GSHP system is more efficient than the ASHP system due to its lower temperature of condenser. (author)

  9. ATLAS Installation: Building a Modern-day "Ship in a Bottle"

    Eisenstein, R

    By now, almost everyone connected with the ATLAS project is aware of its tremendously exciting discovery potential for physics. ATLAS is designed both to search for an as-yet-undiscovered piece of the Standard Model - the Higgs boson - as well as to search for indications of possible new physics - such as Supersymmetry - that lie beyond it. It is just this excitement that has propelled more than 2000 physicists, engineers, technical workers and students from all over the world to commit a significant part of their research careers to this massive undertaking. As the sub-detector components of ATLAS continue to arrive regularly here at CERN, the magnitude - and the quality - of that commitment has become very real. Actual objects exist, in building 180 and other places around the CERN site, waiting for installation into the ATLAS cavern, UX15. That installation will begin next April when ATLAS takes delivery of the experimental hall and associated other buildings and underground structures at Point 1. Indeed,...

  10. Building the gas sector in Mexico

    Navarrete, J.E.

    1996-01-01

    Hydrocarbon reserves in Mexico, ranked 8th in the world, were discussed. On January 1, 1996, Mexico's hydrocarbon proven reserves were 62.1 billion barrels ( a decline of some 10 billion barrels since 1984). Of this 48.8 billion corresponded to crude oil and 13.3 billion to natural gas. Mexico's natural gas pipeline network includes 10,280 kilometres in transmission and 2,211 kilometres in distribution, concentrated along the Gulf of Mexico and in the central and northern regions of the country. A new regulatory framework for natural gas, passed in Congress in 1995, was outlined. The new amendments were designed to strengthen the natural gas industry through private investment in the storage, transportation and distribution of natural gas. Stages for third party access were identified. Increased North American regional integration by interconnections between Mexican, American and Canadian pipeline networks, and the effects of such integration on investments, were examined. figs

  11. Relevant aspects in licensing of radioactive installations at petroleum and gas well logging

    Miranda, Marcia Valeria da E. Sa

    2002-01-01

    The importance of the various factors considered during the process of licensing of radioactive installation for petroleum and gas well logging. This process involves the issuing of some public power acts, the co called Administrative Acts. For the radioactive installations the Administrative Acts are related to the Norm CNEN-NE-6.02 'Licensing of Radioactive Installation'. In the conduction of the licensing of radioactive installation of mobile nuclear measurement devices the safety evaluation of radioactive installation and equipment containing incorporated radiation source are included; certification of radioprotection supervisors; programing and evaluation of the radioprotection inspections; and the conduction of conformal inspection according to the project, safety analysis and audits. An evaluation of the impact of the importance grade attributed to each factor in the optimization of licensing process is related. Finally, the prediction of implantation of a control system for the displacement of radioactive sources in the installation is approached comprehending the up-to-date localization of each source at different work front of the Basis

  12. Greenhouse gas emission for co-generation installation - reduction and selling

    Manev, S.; Stankov, N.; Asenov, A.

    2005-01-01

    According to Kyoto protocol countries which have the availability to buy green house gas emissions from other countries could be made by means of realization of investment project. In this article the authors review the necessary scope of work which have to be done in order particular project for co-generation installation to be realized, according the requirement and their own experience in this field

  13. Silence please? Noise from installations in school buildings; Kan het iets stiller? Installatiegeluid in frisse scholen

    Buijs, J.H.N.; Koornneef, W. [Peutz, Zoetermeer (Netherlands)

    2011-10-15

    Air quality in Dutch school buildings often very poor. Mechanical ventilation systems are installed to improve the air quality. In practice some mechanical ventilation, especially local systems with a fan in or nearby the classroom lead to unacceptable noise levels. This can result in the ventilation system being turned off and thus less air quality. Therefore, a low noise level should be an integral part of the design of the ventilation system. [Dutch] Het binnenklimaat in veel scholen is ronduit slecht, in meer dan 80% van de scholen wordt onvoldoende geventileerd, is er sprake van tocht of is het in de zomer te warm. De in 2009 verschenen ISSO publicatie 89 formuleert eisen en geeft oplossingen om tot verbetering te komen. De praktijk leert echter dat een deel van de voorgestelde mechanische ventilatiesystemen overmatige geluidsniveaus en geluidhinder veroorzaken.

  14. Optimizing design concepts for a building with photovoltaic facility; Systeme d'optimisation pour la conception d'un batiment avec une installation photovoltaique

    Le Bail, Yann; Bedard, Claude [Departement du genie de la construction, ETS, Montreal (Canada); Zmeureanu, Radu [Departement du genie du batiment, civil et de l' environement, Universite de Concordia, Montreal (Canada)

    2010-07-01

    In Canada, the energy used in buildings represents 30% of total national consumption. The use of renewable sources of energy is clearly of interest in efforts to reduce dependency on fossil fuels, greenhouse gas emissions and the total level of energy consumption. This study presents a system for economic and environmental performance optimization of a photovoltaic apparatus installed on the roof of a commercial building. This optimization system was tested on a building in Montreal. The results demonstrate that the apparatus does not give sufficient returns either economically or environmentally in Quebec, due to the fact that the electricity supply there is low-priced and clean but it would provide such returns in Munich, where the repurchase price of photovoltaic and conventional electricity is high and conventional electricity is also a polluter. The optimization system proposed in this study allows the environmental and economic returns from a photovoltaic apparatus to be studied.

  15. COMPREHENSIVE DIAGNOSTIC AND IMPROVEMENT TOOLS FOR HVAC-SYSTEM INSTALLATIONS IN LIGHT COMMERCIAL BUILDINGS

    Abram Conant; Mark Modera; Joe Pira; John Proctor; Mike Gebbie

    2004-10-31

    Proctor Engineering Group, Ltd. (PEG) and Carrier-Aeroseal LLP performed an investigation of opportunities for improving air conditioning and heating system performance in existing light commercial buildings. Comprehensive diagnostic and improvement tools were created to address equipment performance parameters (including airflow, refrigerant charge, and economizer operation), duct-system performance (including duct leakage, zonal flows and thermal-energy delivery), and combustion appliance safety within these buildings. This investigation, sponsored by the National Energy Technology Laboratory, a division of the U.S. Department of Energy, involved collaboration between PEG and Aeroseal in order to refine three technologies previously developed for the residential market: (1) an aerosol-based duct sealing technology that allows the ducts to be sealed remotely (i.e., without removing the ceiling tiles), (2) a computer-driven diagnostic and improvement-tracking tool for residential duct installations, and (3) an integrated diagnosis verification and customer satisfaction system utilizing a combined computer/human expert system for HVAC performance. Prior to this work the aerosol-sealing technology was virtually untested in the light commercial sector--mostly because the savings potential and practicality of this or any other type of duct sealing had not been documented. Based upon the field experiences of PEG and Aeroseal, the overall product was tailored to suit the skill sets of typical HVAC-contractor personnel.

  16. ASSESSMENT OF INSTALLATION WATER QUALITY IN AN EDUCATIONAL BUILDING ON THE BASIS OF LEGIONELLA Sp. CONCENTRATION

    Amelia Beata Staszowska

    2017-06-01

    Full Text Available Legionella are known as one of the dangerous water-borne pathogens, causing severe respiratory tract infections. The aim of this study was to assess the installation water quality in an educational building located in Lublin on the basis of Legionella sp. concentration and physicochemical parameters of cold and hot installation water. Samples (n=60 of cold and hot water were collected for testing from the 10 tapping points during three surveys over a period of five months. The test samples were analyzed for the basic physicochemical parameters of the water quality such as pH, electrical conductivity, temperature, hardness, alkalinity, the total carbon content, the concentration of nitrates, chlorides and sulphates. Additionally, the concentration of calcium, magnesium, iron, manganese and zinc were examined. The presence of Legionella in water samples was measured according the standard methods. The quality of the analyzed water did not raise objections and met the criteria of the Ordinance of the Polish Ministry of Health (2015, pos.1989. The only parameter which did not comply with applicable regulations was the temperature of the supply water and return hot water - it was lower than required. Bacteria of the genus Legionella were detected only in the hot water samples from series 1 when the rate of colonization reached the level of 80%. Among the positive samples, 2 contained less than 1000 CFU/100 ml, 4 samples contained 1x103 to 1x104 CFU/100 ml, and 2 samples contained more than 1x104 CFU/100 ml. The maximum number of CFU in a sample was 1.8x104/100 ml. The most dangerous serogroup L. pneumophila sg 1 was not detected in any of the positive isolated samples. All Legionella - positive samples belonged to L. pneumophila sg 2-14. These findings necessitated a corrective action in the form of thermal disinfection system and its maintenance. Its effectiveness was confirmed by the results of the survey of 2 and 3.

  17. Heat recovery from flue gas of coal fired installations with reduced pollutant emission - the Zittau process

    Mueller, H; Strauss, R; Hofmann, K -D; Suder, M; Hultsch, T; Wetzel, W; Gabrysch, H; Jung, J [Technische Hochschule, Zittau (German Democratic Republic)

    1989-01-01

    Explains the Zittau technology of combined flue gas heat recovery and flue gas desulfurization in small brown coal fired power plants. Steam generators to be equipped with this technology have 6.5 or 10 t/h steam capacity and are intended for combustion of low-grade brown coal (8.2 MJ/kg). An industrial 6.5 t/h prototype steam generator is in operation and it achieves 95% SO{sub 2} removal from flue gas with 5600 to 7800 mg SO{sub 2} per m{sup 3} of dry flue gas. The Zittau technology is available in 3 variants: with maximum waste heat recovery, with partial waste heat recovery or without waste heat recovery and only wet flue gas scrubbing. Two flowsheets of flue gas and suspension circulation are provided. The first variant recovers 25.7% of nominal heat capacity (1.1 thermal MW from a 4.2 MW steam generator with 6.5 t/h steam capacity), which amounts to economizing 2,400 t/a brown coal equivalent over 4,000 annual operating hours. The second variant recovers 6.5% of waste heat, requiring less investment by installing smaller heat exchangers than used in the first variant. All three variants have contact spray separators, suction units and suspension preparation equipment. Flue gas suspension scrubbing is carried out with fly ash produced by the steam generator. This ash is capable of absorbing 50 to 70% of flue gas SO{sub 2}. Supply of additional ash from other plants achieve a further 25% SO{sub 2} removal; a higher desulfurization degree is obtained by adding limestone to suspensions. 5 refs.

  18. Improvement to the gas cycle energy generating installations with heat recuperation

    Tilliette, Zephyr.

    1977-01-01

    Improvement to the gas cycle energy generating installations with heat recuperation, comprising a heat source, supplying a fluid at high temperature and pressure, an expansion turbine, at least one recuperator fitted to the turbine outlet, a cooler and compressor in series, the compressor returning the high pressure fluid to the source after heat exchange in the recuperator with the low pressure fluid from the turbine. It is characterised in that at least one steam generator is connected to the low pressure end of the recuperator [fr

  19. Troubleshooting during Installing Ubuntu Enterprise Cloud Supplement (3) to “Guidelines for Building a Private Cloud Infrastructure"

    Panatic, Zoran; Ali Babar, Muhammad

    2012-01-01

    This document provides supplemental material to the book “Guidelines for building a private cloud infrastructure”. This document describes the issues that can be expected during the different phases of the setup and installation of Ubuntu Enterprise Cloud. This document also contains some useful...

  20. SAFETY ALERT - Failure of brass non-return valves in gas point installations

    HSE Unit

    2016-01-01

    There have been three recent failures in brass non-return valves in separate high pressure gas point installations across CERN. Whilst each was in a different gas service, the visual nature of the failure has been similar.   In all three cases, these components were connected to stainless steel flexible connections and stainless steel pipework. From the metallurgical investigation of the failed component, it appears that the failure is linked to uncontrolled tightening, leading to a localised weakening resulting in premature failure when subjected to pressure. Lead levels in the examined components appear to be a contributing factor to the reduction in ductility but are not identified as the root cause. It has also not been possible to attribute failure to a particular batch of material. The Occupational Health & Safety and Environmental Protection Unit prescribes the following actions to be taken, aligned with the CERN Safety Rules: Verification of all brass non-return valves (prioritising...

  1. Radionuclides in produced water from Norwegian oil and gas installations - concentrations and bioavailability

    Eriksen, D.Oe.; Sidhu, R.; Stralberg, E.; Iden, K.I.; Hylland, K.; Ruus, A.; Roeyset, O.; Berntssen, M.H.G.; Rye, H.

    2006-01-01

    Substantial amounts of produced water, containing elevated levels of radionuclides (mainly 226 Ra and 228 Ra) are discharged to the sea as a result of oil and gas production on the Norwegian Continental Shelf. So far no study has assessed the potential radiological effects on marine biota in connection with radionuclide discharges to the North Sea. The main objective of the project is to establish radiological safe discharge limits for radium, lead and polonium associated with other components in produced water from oil and gas installations on the Norwegian continental shelf. This study reports results indicating that the presence of added chemicals such as scale inhibitors in produced water has a marked influence on the formation of radium and barium sulphates when produced water is mixed with sea water. Thus, the mobility and bioavailability of radium (and barium) will be larger than anticipated. Also, the bioavailability of food-borne radium is shown to increase due to presence of such chemicals. (author)

  2. Radionuclides in produced water from Norwegian oil and gas installations — Concentrations and bioavailability

    Eriksen, D. Ø.; Sidhu, R.; Strålberg, E.; Iden, K. I.; Hylland, K.; Ruus, A.; Røyset, O.; Berntssen, M. H. G.; Rye, H.

    2006-01-01

    Substantial amounts of produced water, containing elevated levels of radionuclides (mainly 226Ra and 228Ra) are discharged to the sea as a result of oil and gas production on the Norwegian Continental Shelf. So far no study has assessed the potential radiological effects on marine biota in connection with radionuclide discharges to the North Sea. The main objective of the project is to establish radiological safe discharge limits for radium, lead and polonium associated with other components in produced water from oil and gas installations on the Norwegian continental shelf. This study reports results indicating that the presence of added chemicals such as scale inhibitors in produced water has a marked influence on the formation of radium and barium sulphates when produced water is mixed with sea water. Thus, the mobility and bioavailability of radium (and barium) will be larger than anticipated. Also, the bioavailability of food-borne radium is shown to increase due to presence of such chemicals.

  3. Air intake device for at least one stand-by aggregate installed in an emergency power supply building

    Stoll, A.; Schilling, R.

    1980-01-01

    Stand-by aggregates are installed in an energency power supply building in order to ensure the cooling of nuclear power plants during accidents. In order to assure the stand-by aggregates to be supplied with combustion air also in the case of fire, each stand-by aggregate is provided with two intake pipes for the combustion air, which are horizontally lead through the building wall on the opposite sides of the energency power supply building. Fire valves are incorporated in the inlet pipes, and one of them will always close in the case of fire. (orig.) [de

  4. A reliability analysis of a natural-gas pressure-regulating installation

    Gerbec, Marko, E-mail: marko.gerbec@ijs.s [Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia)

    2010-11-15

    A case study involving analyses of the operability, reliability and availability was made for a selected, typical, high-pressure, natural-gas, pressure-regulating installation (PRI). The study was commissioned by the national operator of the natural-gas, transmission-pipeline network for the purpose of validating the existing operability and maintenance practices and policies. The study involved a failure-risk analysis (HAZOP) of the selected typical installation, retrieval and analysis of the available corrective maintenance data for the PRI's equipment at the network level in order to obtain the failure rates followed by an elaboration of the quantitative fault trees. Thus, both operator-specific and generic literature data on equipment failure rates were used. The results obtained show that two failure scenarios need to be considered: the first is related to the PRI's failure to provide gas to the consumer(s) due to a low-pressure state and the second is related to a failure of the gas pre-heating at the high-pressure reduction stage, leading to a low temperature (a non-critical, but unfavorable, PRI state). Related to the first scenario, the most important cause of failure was found to be a transient pressure disturbance back from the consumer side. The network's average PRI failure frequency was assessed to be about once per 32 years, and the average unavailability to be about 4 minutes per year (the confidence intervals were also assessed). Based on the results obtained, some improvements to the monitoring of the PRI are proposed.

  5. A reliability analysis of a natural-gas pressure-regulating installation

    Gerbec, Marko

    2010-01-01

    A case study involving analyses of the operability, reliability and availability was made for a selected, typical, high-pressure, natural-gas, pressure-regulating installation (PRI). The study was commissioned by the national operator of the natural-gas, transmission-pipeline network for the purpose of validating the existing operability and maintenance practices and policies. The study involved a failure-risk analysis (HAZOP) of the selected typical installation, retrieval and analysis of the available corrective maintenance data for the PRI's equipment at the network level in order to obtain the failure rates followed by an elaboration of the quantitative fault trees. Thus, both operator-specific and generic literature data on equipment failure rates were used. The results obtained show that two failure scenarios need to be considered: the first is related to the PRI's failure to provide gas to the consumer(s) due to a low-pressure state and the second is related to a failure of the gas pre-heating at the high-pressure reduction stage, leading to a low temperature (a non-critical, but unfavorable, PRI state). Related to the first scenario, the most important cause of failure was found to be a transient pressure disturbance back from the consumer side. The network's average PRI failure frequency was assessed to be about once per 32 years, and the average unavailability to be about 4 minutes per year (the confidence intervals were also assessed). Based on the results obtained, some improvements to the monitoring of the PRI are proposed.

  6. Gas explosion in domestic buildings. The vented gas explosion[sub][/sub

    Tadeusz Chyży

    2014-08-01

    Full Text Available In this paper, the basic information, related to the so-called vented gas explosion, has been presented. The vented explosion it is an explosion, during which the destruction of the weakest elements of the structure occurs. Through the resulting holes (decompressing surfaces can flow both combustion products and non-burned gas mixture. In consequence, reduction of the maximum explosion pressure[i] P[sub]red [/sub][/i] may be significant. Often, a gas explosion occurs inside residential buildings. In this case, natural vents are window and door openings.[b]Keywords[/b]: gas, explosion, combustion, explosion vents

  7. An analysis of the performance of a 2.6 kWp building integrated photovoltaic installation

    Sulaiman Shaari

    2000-01-01

    This paper presents a summary of an analysis of the performance results of a 2.6 kWp Building integrated Photovoltaic (BIPV) installation. The building has fifty Siemens M55 photovoltaic (PV) modules integrated as part of the roof of the building, grid-interactive via an SMA inverter. Data have been compiled and a detailed analysis of its performance was done using a dedicated BIPV computer model called PVSYST2.0. It was found that the general performance of the system was at the lower end of the spectrum mainly due to inherent architectural design of the building. This came by way of shading on the modules casted by shadow: of existing roofs of the building, and adverse effects from temperature increases on the modules due to the heating regimes in the building and lack of ventilation of the modules. The problem was exacerbated by an inverter-to-PV size ratio mismatch. In addition there had been some teething problems during the earlier periods of operation. Lessons from this experience are drawn up to serve as a precautionary note in designing other BIPV installations, especially valuable for applications in tropical climate countries, like Malaysia. (Author)

  8. The photovoltaic power system of Geneva Palexpo Building 6; Installation photovoltaique sur la halle 6 de Geneva Palexpo

    Keller, L.; Rhyner, R.

    2004-07-01

    A 70 kW photovoltaic installation has been constructed on the roof of the new Building 6 of Geneva Palexpo, a compound that hosts various conferences, exhibitions and sporting or other events, counting almost 1.5 million visitors a year, including the International Car Show, which alone attracts more than 700,000 visitors each year. The purpose of this installation is the indirect supply of recharging terminals for electric vehicles. The solar installation and the electric vehicle recharging terminals support an information campaign on solar energy and 'sustainable' mobility. For this purpose various explanatory signs have been placed inside the Geneva Palexpo halls and a promotional stand for renewable energy and 'sustainable' transport was placed inside the International Car Show 2003. This stand had some success: more than 4,000 people took part in the competition organised on this occasion. (author)

  9. STOCHASTIC AND GEOMETRIC REASONING FOR INDOOR BUILDING MODELS WITH ELECTRIC INSTALLATIONS – BRIDGING THE GAP BETWEEN GIS AND BIM

    Y. Dehbi

    2017-10-01

    Full Text Available 3D city and building models according to CityGML encode the geometry, represent the structure and model semantically relevant building parts such as doors, windows and balconies. Building information models support the building design, construction and the facility management. In contrast to CityGML, they include also objects which cannot be observed from the outside. The three dimensional indoor models characterize a missing link between both worlds. Their derivation, however, is expensive. The semantic automatic interpretation of 3D point clouds of indoor environments is a methodically demanding task. The data acquisition is costly and difficult. The laser scanners and image-based methods require the access to every room. Based on an approach which does not require an additional geometry acquisition of building indoors, we propose an attempt for filling the gaps between 3D building models and building information models. Based on sparse observations such as the building footprint and room areas, 3D indoor models are generated using combinatorial and stochastic reasoning. The derived models are expanded by a-priori not observable structures such as electric installation. Gaussian mixtures, linear and bi-linear constraints are used to represent the background knowledge and structural regularities. The derivation of hypothesised models is performed by stochastic reasoning using graphical models, Gauss-Markov models and MAP-estimators.

  10. Providing for energy efficiency in homes and small buildings. Part III. Determining which practices are most effective and installing materials

    None

    1980-06-01

    The training program is designed to educate students and individuals in the importance of conserving energy and to provide for developing skills needed in the application of energy-saving techniques that result in energy-efficient buildings. A teacher guide and student workbook are available to supplement the basic manual. Subjects covered in Part III are: determining which practices are most efficient and economical; installing energy-saving materials; and improving efficiency of equipment.

  11. Installation of a freezer building : a logical, innovative and profitable decision; Installation d'un batiment congelateur : une decision logique, innovatrice et rentable

    Vaillancourt, G. [Nutrifrance Ltd. Saint-Jean-Sur-Richelieu, PQ (Canada)

    2009-12-15

    This article reported on a food company in Saint-Jean-sur-Richelieu, Quebec that has recently modernized its operations by constructing an entire freezer building. Nutrifrance Ltd made the decision to modernize its facility based on long-term energy savings. Three scenarios were analysed for the construction of the freezer building in terms of interior and exterior walls, panels and shelving. The final plans consisted of a freezer within the building, where the outer walls were used as the structure to insulate against heat loss. A heated attic was built to avoid condensation on top of the freezer. Forced air ventilation with a header space was also integrated. The floor consists of 18 centimetres of reinforced concrete every 13 centimetres, giving a thermal resistance of R40. A rapid defrosting process through hot gas is used to recuperate 100 per cent of the heat. Waste heat is used to heat the floors of the office building, the loading areas, and to warm the hot water. The system is controlled by automated machinery to maximize efficiency and costs. The construction offers optimal thermal comfort for employees, which has helped reduce employee turnover. The economical impact has been significant, even after one year of operation, and the energy savings for the electricity bill is 30 per cent lower than predicted. Nutrifrance chose not to use the lowest bid for construction since the ultimate goal was comfort and security. The company predicts a payback period of 14 years. 5 figs.

  12. Experimental engineering section off-gas decontamination facility's fractionator column: installation and performance

    Gilliam, T.M.; Fowler, V.L.; Inman, D.J.

    1978-03-01

    A detailed description of the third column recently installed in the Experimental Engineering Section Off-Gas Decontamination Facility (EES-ODF) is presented. The EES-ODF is being used to provide engineering-scale experiments (nominal gas and liquid flows of 5 scfm and 0.5 gpm, respectively) in the development of the Krypton Absorption in Liquid CO 2 (KALC) process. A detailed discussion of the column's construction is provided. This discussion includes the peripherals associated with the column, such as refrigeration, heat exchangers, instrumentation, etc. The compressibility of Goodloe packing (the packing in the other columns) and the possible reduced throughput due to this compression have revealed the desirablility of a random (i.e., noncompressible) packing. Toward this end, the third column is packed with a new random packing (PRO-PAK). A preliminary comparison between this packing and the woven wire mesh packing (Goodloe) used in the other two columns has been made. Experiments comparing the throughput capacity indicate that the PRO-PAK packing has approximately 60% the capacity of Goodloe for a CO 2 system. When used as a fractionator or stripper with the basic O 2 -Kr-CO 2 KALC system, the PRO-PAK column produced HTU values less than or equal to the GOODLOE columns under similar operating conditions

  13. How to prevent greenhouse gas emissions in electrical installations: lighting energy savings and solar energy approaches

    Yavuz, C.; Aksoy, C. [Sakarya University, Faculty of Engineering, Electrical and Electronics Engineering Department, Serdivan (Turkey)

    2012-07-01

    Day by day greenhouse gas emissions increase dramatically. A passive adaptive method of lighting energy savings, daylight responsive systems are considered one of the best solutions for energy efficiency, saving and prevent CO{sub 2} emissions. Results of an annual experiment which was held in Sakarya University proves the necessity of daylight responsive systems with a 41% energy saving and 942.5 kg of prevented CO{sub 2} emissions Thinking this prevention is realized just only in a 36 m{sup 2} room with the use of 8 luminaries spreading such systems to nationwide, a major amount of greenhouse gas emissions would be prohibited. On the other hand energy saving is not the only way to reduce CO{sub 2} emissions. Again in Sakarya University a project has started to investigate the possibility of illumination of a complete building by using solar energy. This paper evaluates these mentioned systems both in energy efficiency, greenhouse gas emissions prevention and economic point of views. (author)

  14. Designing building energy efficiency programs for greenhouse gas reductions

    Blackhurst, Michael; Lima Azevedo, Ines; Scott Matthews, H.; Hendrickson, Chris T.

    2011-01-01

    Costs and benefits of building energy efficiency are estimated as a means of reducing greenhouse gas emissions in Pittsburgh, PA and Austin, TX. The analysis includes electricity and natural gas consumption, covering 75% of building energy consumption in Pittsburgh and 85% in Austin. Two policy objectives were evaluated: maximize GHG reductions given initial budget constraints or maximize social savings given target GHG reductions. This approach evaluates the trade-offs between three primary and often conflicting program design parameters: initial capital constraints, social savings, and GHG reductions. Results suggest uncertainty in local stocks, demands, and efficiency significantly impacts anticipated outcomes. Annual GHG reductions of 1 ton CO 2 eq/capita/yr in Pittsburgh could cost near nothing or over $20 per capita annually. Capital-constrained policies generate slightly less social savings (a present value of a few hundred dollars per capita) than policies that maximize social savings. However, sectors and end uses targeted for intervention vary depending on policy objectives and constraints. Optimal efficiency investment strategies for some end uses vary significantly (in excess of 100%) between Pittsburgh and Austin, suggesting that resources and guidance conducted at the national scale may mislead state and local decision-makers. Results are used to provide recommendations for efficiency program administrators. - Highlights: → We use public data to estimate local building energy costs, benefits and greenhouse gas reductions. → We use optimization to evaluate trade-offs between program objectives and capital constraints. → Local energy market conditions significantly influence efficiency expectations. → Different program objectives can lead to different effective investment strategies. → We reflect on the implications of our results for efficiency program design.

  15. Designing building energy efficiency programs for greenhouse gas reductions

    Blackhurst, Michael, E-mail: mfb@andrew.cmu.edu [Department of Civil, Architectural and Environmental Engineering, University of Texas at Austin, 1 University Station C1752, Austin, TX 78712 (United States); Lima Azevedo, Ines, E-mail: iazevedo@cmu.edu [Department of Engineering and Public Policy, Carnegie Mellon University, 119 Porter Hall, Pittsburgh, PA 15213 (United States); Scott Matthews, H., E-mail: hsm@cmu.edu [Department of Engineering and Public Policy, Carnegie Mellon University, 119 Porter Hall, Pittsburgh, PA 15213 (United States); Department of Civil and Environmental Engineering, Carnegie Mellon University, 119 Porter Hall, Pittsburgh, PA 15213 (United States); Hendrickson, Chris T., E-mail: cth@andrew.cmu.edu [Department of Civil and Environmental Engineering, Carnegie Mellon University, 119 Porter Hall, Pittsburgh, PA 15213 (United States)

    2011-09-15

    Costs and benefits of building energy efficiency are estimated as a means of reducing greenhouse gas emissions in Pittsburgh, PA and Austin, TX. The analysis includes electricity and natural gas consumption, covering 75% of building energy consumption in Pittsburgh and 85% in Austin. Two policy objectives were evaluated: maximize GHG reductions given initial budget constraints or maximize social savings given target GHG reductions. This approach evaluates the trade-offs between three primary and often conflicting program design parameters: initial capital constraints, social savings, and GHG reductions. Results suggest uncertainty in local stocks, demands, and efficiency significantly impacts anticipated outcomes. Annual GHG reductions of 1 ton CO{sub 2} eq/capita/yr in Pittsburgh could cost near nothing or over $20 per capita annually. Capital-constrained policies generate slightly less social savings (a present value of a few hundred dollars per capita) than policies that maximize social savings. However, sectors and end uses targeted for intervention vary depending on policy objectives and constraints. Optimal efficiency investment strategies for some end uses vary significantly (in excess of 100%) between Pittsburgh and Austin, suggesting that resources and guidance conducted at the national scale may mislead state and local decision-makers. Results are used to provide recommendations for efficiency program administrators. - Highlights: > We use public data to estimate local building energy costs, benefits and greenhouse gas reductions. > We use optimization to evaluate trade-offs between program objectives and capital constraints. > Local energy market conditions significantly influence efficiency expectations. > Different program objectives can lead to different effective investment strategies. > We reflect on the implications of our results for efficiency program design.

  16. A Chronology of Attacks on and Unlawful Interferences with, Offshore Oil and Gas Installations, 1975 – 2010

    Mikhail Kashubsky

    2011-12-01

    Full Text Available Throughout its history, the oil and gas industry has been a subject of environmental protests, labour disputes, tensions with local communities, and it has also been a target of various violent activities ranging from vandalism to political violence, which have impinged on the security of oil industry workers and interfered with operational activities of oil companies on numerous occasions. Although a considerable number of attacks on oil and gas infrastructure occurred over the course of the industry’s existence, most of those attacks were directed against onshore petroleum targets. Compared to onshore petroleum infrastructure, attacks on offshore oil and gas installations are relatively rare. The following chronology provides details of attacks, unlawful interferences, and security incidents involving offshore oil and gas installations that happened between 1975 and 2010. 

  17. U. S. EPA voluntary programs and the oil and gas industry : Natural Gas STAR and Energy STAR Buildings Partnership

    Gunnung, P.

    2000-01-01

    The structure of two EPA programs directed towards wasted energy in buildings, reducing emissions, increasing energy efficiency and maximizing profits are described. The programs are based on a partnership approach between EPA and participants, and involve elements of plans and performance benchmarks, an integrated approach and communications and demonstration of successful initiatives. EPA provides planning and technical support in the form of a website, software tools, manuals, electronic sources and a purchasing tool kit. The Energy STAR Building Partnership has over 3,000 participants, and can boast of a cumulative saving of over $ 1.4 billion in energy bills and carbon dioxide emission reduction of 44.1 billion pounds, resulting from efficiency upgrades. The Natural Gas Partnership between the EPA and the oil and natural gas industry to cost effectively reduce methane emissions from the production, transmission, and distribution of natural gas also has had a number of successful initiatives such as replacement or retrofit of high bleed pneumatic devices, installation of flash tank separators on glycol dehydrators and other partner-reported projects such as replacement of wet seals with dry seals on compressors and connecting glycol pump to vapour recovery unit. As a results of these and other initiatives, annual methane emission was reduced by 22.2 bcf in 1998 as opposed to 3.4 bcf prior to the beginning of the program in 1993. Approximately 67 per cent of all reductions can be attributed to partner innovation. Overall assessment is that the program is innovative, achieves both economic and environmental goals, facilitates government and industry cooperation and is living proof that non-regulatory, cooperative programs work

  18. Solar Heating and Cooling of Residential Buildings: Sizing, Installation and Operation of Systems.

    Colorado State Univ., Ft. Collins. Solar Energy Applications Lab.

    This training course and a companion course titled "Design of Systems for Solar Heating and Cooling of Residential Buildings," are designed to train home designers and builders in the fundamentals of solar hydronic and air systems for space heating and cooling and domestic hot water heating for residential buildings. Each course, organized in 22…

  19. Technological features of installation of transformable low-rise buildings from sandwich panels

    Pleshivtsev Aleksandr Aleksandrovich

    2018-04-01

    Full Text Available Subject of research: organizational and technological solutions are considered in the construction of transformable low-rise residential buildings using sandwich panels. Aims: rational choice of organizational and technological solutions for the rhythmic construction of the underground and above-ground part of the transformable low-rise buildings in order to reduce labor costs and construction time. Materials and methods: methods of computer modeling of the technological processes are used to determine the duration of the construction of the low-rise buildings. Results: rational methods for erecting a complex of transformable low-rise buildings are defined, parameters of technological processes are established, an analysis of technological operations is provided for the construction of transformable low-rise residential buildings using sandwich panels. Conclusions: now organizational and technological solutions for the construction of transformable low-rise residential buildings with the use of sandwich panels reduce labour costs, increase the construction pace and as well as the using of improved technological processes in the construction of such buildings leads to a reduction in construction time.

  20. Electrica.l Insta.lla.tions in Multi-storey Buildings

    different diversity factors of the individual sections. However .... auxiliary drives for the heating system and ventila- tion, as well as ... For multi-storey buildings preference is generally given to ... Group p. f correction is expedient if large banks of.

  1. Some problems of evaluating environmental impacts of nuclear power installation building and operation

    Uvirova, E.

    1984-01-01

    The impacts of the construction and operation of a nuclear power installation on the natural environment is discussed, namely on changes in the landscape profile, in the structure of settlement and large-scale agricultural production, the requisition of agricultural land, changes in transport systems, etc., as well as approaches to the evaluation of these environmental impacts with the aim of preserving the optimal state of inter-relations between man and the natural environment. (author)

  2. Low-Cost Gas Heat Pump for Building Space Heating

    Garrabrant, Michael [Stone Mountain Technologies, Inc., Johnson City, TN (United States); Keinath, Christopher [Stone Mountain Technologies, Inc., Johnson City, TN (United States)

    2016-10-11

    , which will allow for improved load matching. In addition, the energy savings analysis showed that a house in Albany, NY, Chicago, IL and Minneapolis, MN would save roughly 32, 28.5 and 36.5 MBtu annually when compared to a 100% efficient boiler, respectively. The gas absorption heat pump achieves this performance by using high grade heat from the combustion of natural gas in combination with low grade heat extracted from the ambient to produce medium grade heat suitable for space and water heating. Expected product features include conventional outdoor installation practices, 4:1 modulation, and reasonable economic payback. These factors position the technology to gain significant market penetration, resulting in a large reduction of energy use and greenhouse gas emissions for residential space heating.

  3. Prevention of radioactive gas seeping into buildings through constructive materials

    Khaydarov, R.A.; Gapurova, O.U.; Khaydarov, R.R.

    2004-01-01

    Full text: One of possible method of realization of the terrorist acts is using gases and liquids, which easily permeate through the constructive materials of walls, floor, ceiling, roof, etc. into buildings by the capillary action of the pores. Toxic volatile organic compounds, organic and inorganic gases, radioactive elements, especially, which emits alpha particles can be used as the dangerous substances. Increased ventilation may help in removing the gases, but can actually increase the gases level by increasing the suction through the pores of concrete. If the gases and liquids are soluble in water and are easily volatilized from it, they can also get by groundwater up to underground structures and penetrate inside through opening and pores in concrete or pushed by hydrostatic pressure. The purpose of this work is creating a method to reduce concentration of toxic and radioactive gases in homes, buildings, underground buildings, tunnels, hangars, garages, bomb shelters, etc. The most effective method to prevent penetration of radionuclides into premises of buildings and underground structures through walls, roofs, floors is using special chemicals, which seal micropores inside the construction materials against gases. Worked out chemicals which consist of blend of polymeric compounds are described in the paper. Radioactive gases permeability in constructive materials after treatment by chemicals was studied. Influence of types of cement, sand and gypsum, preliminary treatment by different chemicals, different types of polymeric compounds, time between treatments, moisture of materials, time between preparation of chemicals and treatment of materials (aging of chemicals), time between treatment of concrete and testing (aging of treated concrete) were examined. Experiments have shown that our method allows reducing the coefficient of gas permeability 200 - 400 times

  4. Experimental optimization of temperature distribution in the hot-gas duct through the installation of internals in the hot-gas plenum of a high-temperature reactor

    Henssen, J.; Mauersberger, R.

    1990-01-01

    The flow conditions in the hot-gas plenum and in the adjacent hot-gas ducts and hot-gas pipes for the high-temperature reactor project PNP-1000 (nuclear process heat project for 1000 MW thermal output) have been examined experimentally. The experiments were performed in a closed loop in which the flow model to be analyzed, representing a 60deg sector of the core bottom of the PNP-1000 with connecting hot-gas piping and diverting arrangements, was installed. The model scale was approx. 1:5.6. The temperature and flow velocity distribution in the hot-gas duct was registered by means of 14 dual hot-wire flowmeters. Through structural changes and/or the installation of internals into the hot-gas plenum of the core bottom offering little flow resistance coolant gas temperature differentials produced in the core could be reduced to such an extent that a degree of mixture amounting to over 80% was achieved at the entrance of the connected heat exchanger systems. Thereby the desired goal of an adequate degree of mixture of the hot gas involving an acceptable pressure loss was reached. (orig.)

  5. Statistical analysis of electromagnetic radiation measurements in the vicinity of GSM/UMTS base station installed on buildings in Serbia.

    Koprivica, Mladen; Slavkovic, Vladimir; Neskovic, Natasa; Neskovic, Aleksandar

    2016-03-01

    As a result of dense deployment of public mobile base stations, additional electromagnetic (EM) radiation occurs in the modern human environment. At the same time, public concern about the exposure to EM radiation emitted by such sources has increased. In order to determine the level of radio frequency radiation generated by base stations, extensive EM field strength measurements were carried out for 664 base station locations, from which 276 locations refer to the case of base stations with antenna system installed on buildings. Having in mind the large percentage (42 %) of locations with installations on buildings, as well as the inevitable presence of people in their vicinity, a detailed analysis of this location category was performed. Measurement results showed that the maximum recorded value of total electric field strength has exceeded International Commission on Non-Ionizing Radiation Protection general public exposure reference levels at 2.5 % of locations and Serbian national reference levels at 15.6 % of locations. It should be emphasised that the values exceeding the reference levels were observed only outdoor, while in indoor total electric field strength in no case exceeded the defined reference levels. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Statistical analysis of electromagnetic radiation measurements in the vicinity of GSM/UMTS base station installed on buildings in Serbia

    Koprivica, Mladen; Slavkovic, Vladimir; Neskovic, Natasa; Neskovic, Aleksandar

    2016-01-01

    As a result of dense deployment of public mobile base stations, additional electromagnetic (EM) radiation occurs in the modern human environment. At the same time, public concern about the exposure to EM radiation emitted by such sources has increased. In order to determine the level of radio frequency radiation generated by base stations, extensive EM field strength measurements were carried out for 664 base station locations, from which 276 locations refer to the case of base stations with antenna system installed on buildings. Having in mind the large percentage (42 %) of locations with installations on buildings, as well as the inevitable presence of people in their vicinity, a detailed analysis of this location category was performed. Measurement results showed that the maximum recorded value of total electric field strength has exceeded International Commission on Non-Ionizing Radiation Protection general public exposure reference levels at 2.5 % of locations and Serbian national reference levels at 15.6 % of locations. It should be emphasised that the values exceeding the reference levels were observed only outdoor, while in indoor total electric field strength in no case exceeded the defined reference levels. (authors)

  7. Numerical model for stack gas diffusion in terrain with buildings. Variations in air flow and gas concentration with additional building near stack

    Sada, Koichi; Michioka, Takenobu; Ichikawa, Yoichi; Komiyama, Sumito; Numata, Kunio

    2009-01-01

    A numerical simulation method for predicting atmospheric flow and stack gas diffusion using a calculation domain of several km around a stack under complex terrain conditions containing buildings has been developed. The turbulence closure technique using a modified k-ε-type model without a hydrostatic approximation was used for flow calculation, and some of the calculation grids near the ground were treated as buildings using a terrain-following coordinate system. Stack gas diffusion was predicted using the Lagrangian particle model, that is, the stack gas was represented by trajectories of released particles. The developed numerical model was applied to a virtual terrain and building conditions in this study prior to the applications of a numerical model for real terrain and building conditions. The height of the additional building (H a ), located about 200 m leeward from the stack, was varied (i.e., H a =0, 20, 30 and 50 m), and its effects on airflow and the concentration of stack gas at a released height of 75 m were calculated. Furthermore, effective stack height, which was used in the safety analysis of atmospheric diffusion for nuclear facilities in Japan, was evaluated from the calculated ground-level concentration of stack gas. The cavity region behind the additional building was calculated, and turbulence near the cavity was observed to decrease when the additional building was present. According to these flow variations with the additional building, tracer gas tended to diffuse to the ground surface rapidly with the additional building at the leeward position of the cavity, and the ground-level stack gas concentration along the plume axis also increased with the height of the additional building. However, the variations in effective stack height with the height of the additional building were relatively small and ranged within several m in this study. (author)

  8. Solar energy system installed at the North Georgia APDC office building

    1979-01-01

    A hydronic, automatic drain-down solar heating and cooling system is described. The system provides solar heat exchange from a 2,001 square foot effective collector area and supplies 65-70 percent of the building's cooling demand, 90-95 percent of the heating demand, and domestic hot water. The acceptance test plan and results, system operation and maintenance, and predicted system performance are presented.

  9. The robustness of buildings and installations. Part 2; Robuustheid van gebouwen en installaties. Deel 2

    Leijten, J.L. [Afdeling Climate Design and Environment, Faculteit Bouwkunde, Technische Universiteit Delft, Delft (Netherlands); Kurvers, S.R. [Apogeum Indoor Environment Consult, Gouda (Netherlands)

    2011-03-15

    In a previous article of this magazine (January 2007) attention was paid to the hypothesis of the robustness of a building. Since then, the hypothesis has been extended and refined. The robustness of an office building was defined as the measure by which the building lives up to its design purpose in a real life situation. In the refined hypothesis more attention is given to the way occupants react to the indoor environment as a whole. Robustness is expected to be particularly increased when the environmental 'Gestalt', the total working environment as perceived by occupants, promotes acceptance of the indoor environment. [Dutch] Een voorgaand artikel in dit tijdschrift (januari 2007) behandelde de gebouwrobuustheidshypothese, waarin de robuustheid van een kantoorgebouw werd gedefinieerd als de mate waarin het binnenmileu in het gerealiseerde gebouw in de praktijk voldoet aan zijn ontwerpdoelstelling. Sindsdien is de hypothese uitgebreid en verfijnd met speciale aandacht voor de manier waarop gebruikers reageren op het binnenmilieu als geheel. De verwachting is dat de robuustheid van een gebouw verder zal toenemen wanneer de omgevings-Gestalt de acceptatie van het binnenmilieu bevordert. De omgevings-Gestalt is het geheel van de werkomgeving zoals de gebruikers die ervaren.

  10. Assessing the safety aspects for use of multilayer pipes in gas distribution of domestic installation; Avaliacao dos aspectos de seguranca para utilizacao de tubos multicamada em instalacoes de distribuicao de gas em residencias

    Bratfisch, Carlos do Amaral Coutinho [Bratfisch - Engenharia em Gas, Sao Paulo, SP (Brazil); Emmeti, Sao Paulo, SP (Brazil); Collela, Ricardo [FGS Brasil Industria e Comercio Ltda., Cotia, SP (Brazil)

    2012-07-01

    The gas distribution networks average flow at the Brazilian market is low and the operating pressure is less than 2.0 kgf/cm{sup 2}. These values are lower if compared to other countries and due this, gas distribution companies, major builders and developers have started a movement to find alternatives to reduce their installation costs, and they have identified in other countries the multilayer system. Because of the great interest of the consumer market for this alternative, and since there is no standards in Brazil that could regulate it, a technical committee was established under the ABNT in order to prepare a standard draft meeting the local market particularities as well this technology requirements. Then it was initiated a quest looking for the knowledge of the 'state of the art' of this technology in various locations around the world, especially Europe, Asia and Oceania, which shows that, with few exceptions, the knowledge of this alternative is still on the beginning, and even in countries where this system is a pioneer some doubts exist with respect to their usage limit. The multilayer system materials were already used at hot and cold water networks for more than twelve years, but only after that it was made an adaptation for building installations of gas distribution networks. Due the need to search and establish safety criteria both with respect to the product as its installation shape, did the necessary motivation to perform a more detailed study of this new technology, meeting the needs of this market. The intention is to present to the consumer market a series of comparative data definitions and techniques to identify this as a modern, updated, economic, efficient and safe alternative option for gas distribution networks. (author)

  11. The choice of primary energy source including PV installation for providing electric energy to a public utility building - a case study

    Radomski, Bartosz; Ćwiek, Barbara; Mróz, Tomasz M.

    2017-11-01

    The paper presents multicriteria decision aid analysis of the choice of PV installation providing electric energy to a public utility building. From the energy management point of view electricity obtained by solar radiation has become crucial renewable energy source. Application of PV installations may occur a profitable solution from energy, economic and ecologic point of view for both existing and newly erected buildings. Featured variants of PV installations have been assessed by multicriteria analysis based on ANP (Analytic Network Process) method. Technical, economical, energy and environmental criteria have been identified as main decision criteria. Defined set of decision criteria has an open character and can be modified in the dialog process between the decision-maker and the expert - in the present case, an expert in planning of development of energy supply systems. The proposed approach has been used to evaluate three variants of PV installation acceptable for existing educational building located in Poznań, Poland - the building of Faculty of Chemical Technology, Poznań University of Technology. Multi-criteria analysis based on ANP method and the calculation software Super Decisions has proven to be an effective tool for energy planning, leading to the indication of the recommended variant of PV installation in existing and newly erected public buildings. Achieved results show prospects and possibilities of rational renewable energy usage as complex solution to public utility buildings.

  12. Relevant aspects in licensing of radioactive installations at petroleum and gas well logging; Aspectos relevantes no licenciamento de instalacoes radiativas em perfilagem de pocos de petroleo ou gas

    Miranda, Marcia Valeria da E. Sa [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2002-07-01

    The importance of the various factors considered during the process of licensing of radioactive installation for petroleum and gas well logging. This process involves the issuing of some public power acts, the co called Administrative Acts. For the radioactive installations the Administrative Acts are related to the Norm CNEN-NE-6.02 'Licensing of Radioactive Installation'. In the conduction of the licensing of radioactive installation of mobile nuclear measurement devices the safety evaluation of radioactive installation and equipment containing incorporated radiation source are included; certification of radioprotection supervisors; programing and evaluation of the radioprotection inspections; and the conduction of conformal inspection according to the project, safety analysis and audits. An evaluation of the impact of the importance grade attributed to each factor in the optimization of licensing process is related. Finally, the prediction of implantation of a control system for the displacement of radioactive sources in the installation is approached comprehending the up-to-date localization of each source at different work front of the Basis.

  13. Flue gas heat recovery operating below the dew point and its utilisation for low temperature heating installations

    Wilsdorf, J.

    1986-11-01

    This paper deals at first with the characteristics of two principal systems for the flue gas heat recovery by reducing the temperature below the dew point. With test results on experimental plants are shown the typical differences between surface and direct contact heat exchange. A second part informs about experiences from the application for low temperature heating installations, especially about thermodynamics condensate quality and technical design. The possible increasing of the efficiency ranges between 10 to 20 per cent.

  14. Method for the combustion of a gas, in fixed bed, with an oxidized solid and associated installation

    Abanades García, Juan Carlos; Fernández García, José Ramón

    2014-01-01

    [EN] The present invention pertains to the field of the generation of energy from combustible gases, incorporating the capture of carbon dioxide for use or permanent storage and, specifically relates to cyclical methods of gas combustion with oxidized solids (chemical looping processes), in fixed bed, for solving the problem of controlling temperature in the combustion of gaseous fuels in fixed beds of metal oxides operating at high pressures, and also the associated installation.

  15. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas. Final report

    1980-06-01

    This document is the Final Report of the Solar Energy System Installed at the First Solar Heated Office Building, One Solar Place, Dallas, Texas. The Solar System was designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 Solargenics, series 76, flat plate collectors with a total area of 1596 square feet. The solar loop circulates an ethylene glycol-water solution through the collectors into a hot water system heat exchanger. The hot water storage subsystem consists of a heat exchanger, two 2300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water fixtures. The building cold water system provides make-up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described. The system became operational July 11, 1979.

  16. Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

    1980-01-01

    A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

  17. Favourable environmental factors for shaft furnace installation for gas carbonitriding and hardening

    Fuchs, H. (Solo-Industrieofenbau, Biehl-Bienne (Switzerland))

    In this lecture we do not primarily speak about the shaft furnace installation as one could think when reading the title - but about one quenching system - mounted over the shaft furnace installation. This quenching system permits a hardening in several mediums, without any formation of flames, smoke and vapour, and causes the surfaces of the pieces to be free of tinder. Moreover, the security for the work staff in the heat treatment shops are highly improved.

  18. Thermal Performance Analysis of Solar Collectors Installed for Combisystem in the Apartment Building

    Žandeckis, A.; Timma, L.; Blumberga, D.; Rochas, C.; Rošā, M.

    2012-01-01

    The paper focuses on the application of wood pellet and solar combisystem for space heating and hot water preparation at apartment buildings under the climate of Northern Europe. A pilot project has been implemented in the city of Sigulda (N 57° 09.410 E 024° 52.194), Latvia. The system was designed and optimised using TRNSYS - a dynamic simulation tool. The pilot project was continuously monitored. To the analysis the heat transfer fluid flow rate and the influence of the inlet temperature on the performance of solar collectors were subjected. The thermal performance of a solar collector loop was studied using a direct method. A multiple regression analysis was carried out using STATGRAPHICS Centurion 16.1.15 with the aim to identify the operational and weather parameters of the system which cause the strongest influence on the collector's performance. The parameters to be used for the system's optimisation have been evaluated.

  19. Monitoring the performance of single and triple junction amorphous silicon modules in two building integrated photovoltaic (BIPV) installations

    Eke, Rustu; Senturk, Ali

    2013-01-01

    Highlights: • The first and the largest BIPV of Turkey were installed. • Single and triple junction amorphous module performances in BIPV applications are analyzed. • Total generated electricity of the BIPV system is measured as 103,702 kW h for 36 months of operation. • Annual energy rating is calculated as 856 kW h/kWp for a non-optimally oriented plant. • The PR of the system is found 0.74 and 0.81 for PV systems on towers and facade respectively. - Abstract: Mugla is located in south west Turkey at 37°13′N latitude and 28°36′E longitude with yearly sum of horizontal global irradiation exceeding 1700 kW h per square meter. Mugla has a Mediterranean Climate which is characterized by long, hot and dry summers with cool and wet winters. Mugla Sıtkı Kocman University is the largest “PV Park” in Turkey consisting of 100 kWp installed Photovoltaic Power Systems (PVPSs) with different PV applications. The 40 kWp building integrated photovoltaic (BIPV) system which is the first and largest in Turkey was installed on the façade and the two towers of the “Staff Block of the Education Faculty’s Building” of Mugla Sıtkı Kocman University in February 2008. Triple junction amorphous silicon photovoltaic modules are used on the façade and single junction amorphous silicon PV modules are used on the East and West towers of the building. In this paper, the 40 kWp BIPV system in Mugla, Turkey is presented, and its performance is evaluated. Energy rating (kW h/kWp energy yield), efficiencies and performance ratios of both applications are also evaluated for 36 months of operation. Daily, monthly and seasonal variations in performance parameters of the BIPV system in relation to solar data and meteorological parameters and outdoor performance of two reference modules (representing the modules on façade and towers) in a summer and a winter day are also investigated

  20. Calibration on Pegase of a selective D.R.G. installation for short life and long life fission gas

    Vasnier, F.

    1968-01-01

    Pegase irradiation loops are equipped with a detection installation which measures the global activity of short-life and long-life fission gases which are released in CO 2 , but the reduced size of circuits in the loop results in an accumulation of long life fission gases, and therefore in problems in the interpretation of measured signals. Thus, the authors propose an additional detection installation which allows long-life fission gases to be separately measured. The principle is to ensure a partial decay of the sampled gas by imposing an additional transit time in order to get rid of short-life fission gases which have a radioactive period of some tenths of a second. A second detector is then used to measure the residual activity of long-life fission gases. The author describes the installation (the normal circuit and the modified circuit), reports the performed tests and the calibration, presents and discusses the obtained results and the installation sensitivity (for short-life and long-life fission gases), and reports their application to the relationship between DRG (sheath failure detection) signals obtained on Pegase and on EDF and EL4 reactors

  1. Seismic Response and Performance Evaluation of Self-Centering LRB Isolators Installed on the CBF Building under NF Ground Motions

    Junwon Seo

    2016-01-01

    Full Text Available This paper mainly treats the seismic behavior of lead-rubber bearing (LRB isolation systems with superealstic shape memory alloy (SMA bending bars functioning as damper and self-centering devices. The conventional LRB isolators that are usually installed at the column bases supply extra flexibility to the centrically braced frame (CBF building with a view to elongate its vibration period, and thus make a contribution to mitigating seismic acceleration transferred from ground to structure. However, these base isolation systems are somehow susceptible to shear failure due to the lack of lateral resistance. In the construction site, they have been used to be integrated with displacement control dampers additionally withstanding lateral seismic forces. For this motivation, LRB isolation systems equipped with superelastic SMA bending bars, which possess not only excellent energy dissipation but also outstanding recentering capability, are proposed in this study. These reinforced and recentering LRB base isolators are modeled as nonlinear component springs, and then assigned into the bases of 2D frame models used for numerical simulation. Their seismic performance and capacity in the base-isolated frame building can be evaluated through nonlinear dynamic analyses conducted with historic ground motion data. After comparative study with analyses results, it is clearly shown that 2D frame models with proposed LRB isolators generally have smaller maximum displacements than those with conventional LRB isolators. Furthermore, the LRB isolation systems with superelastic SMA bending bars effectively reduce residual displacement as compared to those with steel bending bars because they provide more flexibility and recentering force to the entire building structure.

  2. Greenhouse Gas Abatement with Distributed Generation in California's Commercial Buildings

    Stadler, Michael; Marnay, Chris; Cardoso, Goncalo; Megel, Olivier; Siddiqui, Afzal; Lai, Judy

    2009-01-01

    Lawrence Berkeley National Laboratory (LBL) is working with the California Energy Commission (CEC) to determine the role of distributed generation (DG) in greenhouse gas reductions. The impact of DG on large industrial sites is well known, and mostly, the potentials are already harvested. In contrast, little is known about the impact of DG on commercial buildings with peak electric loads ranging from 100 kW to 5 MW. We examine how DG with combined heat and power (CHP) may be implemented within the context of a cost minimizing microgrid that is able to adopt and operate various smart energy technologies, such as thermal and photovoltaic (PV) on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We use a mixed-integer linear program (MILP) that has the minimization of a site's annual energy costs as objective. Using 138 representative commercial sites in California (CA) with existing tariff rates and technology data, we find the greenhouse gas reduction potential for California's commercial sector. This paper shows results from the ongoing research project and finished work from a two year U.S. Department of Energy research project. To show the impact of the different technologies on CO2 emissions, several sensitivity runs for different climate zones within CA with different technology performance expectations for 2020 were performed. The considered sites can contribute between 1 Mt/a and 1.8 Mt/a to the California Air Resources Board (CARB) goal of 6.7Mt/a CO2 abatement potential in 2020. Also, with lower PV and storage costs as well as consideration of a CO2 pricing scheme, our results indicate that PV and electric storage adoption can compete rather than supplement each other when the tariff structure and costs of electricity supply have been taken into consideration. To satisfy the site's objective of minimizing energy costs, the batteries will be charged also by CHP systems during off-peak and mid-peak hours and

  3. High performance gas adsorption and separation of natural gas in two microporous metal-organic frameworks with ternary building units.

    Wang, Dongmei; Zhao, Tingting; Cao, Yu; Yao, Shuo; Li, Guanghua; Huo, Qisheng; Liu, Yunling

    2014-08-14

    Two novel MMOFs, JLU-Liu5 and JLU-Liu6, are based on ternary building units and exhibit high adsorption selectivity for CO2, C2H6 and C3H8 over CH4, which is attributed to steric effects and host-guest interactions. These MMOFs are promising materials for gas adsorption and natural gas purification.

  4. 77 FR 7211 - Pacific Gas and Electric Company, Diablo Canyon Independent Spent Fuel Storage Installation...

    2012-02-10

    ... NUCLEAR REGULATORY COMMISSION [Docket No. 72-26; NRC-2011-0110] Pacific Gas and Electric Company...) issued NRC Materials License No. SNM-2511 to the Pacific Gas and Electric Company (PG&E) for the Diablo.... 5. TS 3.1.2, ``Spent Fuel Storage Cask (SFSC) Heat Removal System,''--revise to allow the HI-STORM...

  5. Performance evaluation of gas-power strategies for building energy conservation

    Gabbar, Hossam A.; Runge, Jason; Bondarenko, Daniel; Bower, Lowell; Pandya, Devarsh; Musharavati, Farayi; Pokharel, Shaligram

    2015-01-01

    Highlights: • Comparison of natural gas and hydrogen fuels for energy conservation in buildings. • Comparison between hydrogen and natural gas fuel cell is performed. • Simulations of building energy supply. • Performance evaluation of two potential gas-power supply scenarios in buildings. • Natural gas fuel cell showed better performance over hydrogen fuel cell. - Abstract: The work provided herein involves a comparison of natural gas and hydrogen fuels for the purpose of energy conservation for buildings via alternative energy generation methodologies. A case study simulation was developed for an average type of commercial building, a nine storey hotel located in Toronto. The two alternative energy source case studies involved the generation of hydrogen via the wind turbine for the fuel cell, and the use of natural gas directly in the steam reforming fuel cell. The simulations for both scenarios were run and the recorded results were compared to the original case study, as well as between the scenarios. To supply for the base load of the building the fuel cells were given the same kW rating for both scenarios. The identification of all existing technologies for hydrogen gas and natural gas has been carried out, and the similar technologies between the two gases were found. For the purpose of realism, only existing purchasable technologies were considered in this paper. Due to the lack of commercially available technologies for hydrogen gas, only a comparison of fuel cell systems could be accomplished. Over the course of the investigative work it was found that when there is no direct supply of hydrogen to the site of utilization, the natural gas fuel cell is beneficial to the building due to its greater efficiency and lower cost. The major drawback for the hydrogen gas fuel cell, when the on-site generation is involved, is that no thermal power extraction systems currently exist for purchase and utilization in the buildings

  6. Heat recovery from flue gas of coal fired installations with reduced pollutant emission - the Zittau process

    Mueller, H; Strauss, R; Hofmann, K -D; Suder, M; Hultsch, T; Wetzel, W; Gabrysch, H; Jung, J [Technische Hochschule, Zittau (German Democratic Republic)

    1988-12-01

    Reviews the technology applied in the Zittau process for flue gas heat recovery and flue gas desulfurization in small brown coal fired power plants. Steam generators have a capacity of 6.5 or 10 t/h, low grade fuel with 8.2 MJ/kg calorific value is combusted. Technology has been developed on an experimental 10 t/h steam generator since 1986; an industrial 6.5 t/h prototype steam generator is now in operation achieving 95% SO{sub 2} removal from flue gas with 5600 to 7800 mg SO{sub 2} per m{sup 3} of dry flue gas. The Zittau technology is available in 3 variants: with maximum waste heat recovery, with partial waste heat recovery or without waste heat recovery and only wet flue gas scrubbing. Two flowsheets of flue gas and suspension circulation are provided. The first variant recovers 25.7% of nominal heat capacity (1.1 thermal MW from a 4.2 MW steam generator with 6.5 t/h steam capacity), the second variant recovers 6.5% of waste heat by reducing heat exchangers to 20% of the size of the first variant. Flue gas suspension scrubbing utilizes power plant ash, which is capable of absorbing 50 to 70% of SO{sub 2}, additional 25% SO{sub 2} removal is achieved by providing either 40% ash from another power plant or limestone for suspensions. Various technological details are included. 5 refs.

  7. Natural Gas Versus Nuclear New Build Versus Life Extension

    Barron, B.

    2013-01-01

    Proven natural gas reserves and production in the USA have continued to increase in recent years. This is due to the exploration of shale formations and the expanded use of hydraulic fracking technology. Looking forward, we can expect that high crude oil prices will sustain natural gas production at current levels (approximately 25% of natural gas production in the USA is a by-product of crude oil drilling), and the natural gas liquid cuts are priced with crude oil. Continued drilling in the near term for natural gas is required by lease obligations and by commitments to investors

  8. Installation design of pump motor control systems for supplied of the RSG-GAS secondary raw water cooling system

    Kiswanto; Teguh Sulistyo; M-Taufik

    2013-01-01

    It has designed already of an installation of the pump motor control system for supplied of raw water to fulfil the RSG-GAS secondary cooling system. The installation design of this plant is used to supply electrical energy from PLN and 3 phase generator to operate the pump motor embedded multilevel type, capacity, Q = 30 m 3 /h; electric power, PN = 4 kW; voltage, 380V/3-/50Hz, and Y connections that can be operated manually or automatically by using the automatic transfer switch. The results obtained recapitulation total load of 4 kW, the magnitude of the nominal current of 9.5 A; kind of safety and capacity are used NFB 16 A, use of this type of cable to the control panel is PLN NYY 6 mm 2 diameter maximum current capacity of 25 A cable and use the control panel to the pump motor cable type NYY 4 mm 2 diameter maximum current capacity of 20 A. The design of the pump motor control system installation is ready to be implemented. (author)

  9. The three-dimensional flow in the chamber of a gas centrifuge with an installed obstacle

    Elsholz, E.

    1977-01-01

    The flow-field in a very fast rotating chamber under the presence of a stationarily installed obstacle is calculated numerically from the complete set of Navier-Stokes-equations. A special differential approximation applied, provides stable and non-oscillating solutions even within the region of very small Ekman-numbers. This type of approximation will be derived and its advantages are discussed. Finally, a numerical result is presented which includes strong radial density gradients and shows very clearly the compressible effects as well as the mechanism of vortex shedding generated by the obstacle. (orig.) [de

  10. Development of a computer system for support and documentation of clearance of buildings of nuclear installations - 59278

    Winkler, Christoph; Woerlen, Stefan; Thierfeldt, Stefan; Schartmann, Frank

    2012-01-01

    Clearance of buildings of nuclear installations in Germany has to comply with general requirements laid down in Section 29 of the German Radiation Protection Ordinance (RPO; Strahlenschutzverordnung), clearance levels as stipulated in Table 1 of Annex III RPO and technical guidance given in the technical standard DIN 25457. Clearance procedures are usually proposed by the licensee and are made part of a decommissioning licence after appropriate review by the authorities. The clearance procedures consist of a radiological characterisation of the various parts of the buildings, a decontamination step if necessary, followed by measurements for checking the success of decontamination, and the actual decision measurements for demonstrating compliance with clearance levels. These three steps rely on various measurement methods, selected depending on the relevant radionuclides to be measured, like sampling with subsequent gamma spectrometry (and if necessary separate evaluation of beta and alpha emitting nuclides), measurements with surface contamination monitory and in situ gamma spectrometry. For a nuclear power plant, the number of samples taken during this procedure can easily reach a few 10, 000, while the number of single measurements can reach several 100, 000 single surface measurements and several 10, 000 measurements with in situ gamma spectrometry. This large number of data together with the correct interpretation according to the valid nuclide vector, the penetration depth of the contamination, the correction for radioactive decay etc have to be managed, which is a error-prone process if carried out manually or with insufficient support by customised software. For this reason, a versatile software tool has been developed by Brenk Systemplanung GmbH that supports the operator in all aspects of clearance of buildings, based on the extensive experience with various clearance procedures in nuclear power plants that Brenk Systemplanung has carried out in the past

  11. A method for starting up the gas isolating section of a benzine pyrolysis installation

    Bruskin, Yu.A.; Gorokhov, V.V.; Kotler, L.D.; Shevchenko, K.N.; Zeldin, V.Ye.

    1982-01-01

    In the method for starting up a gas isolation section of a benzine pyrolysis unit, which includes starting the demethanizer in a steaming mode, starting the ethane and ethylene and propane and propylene towers, filling the ethylene cooling system with a hydrocarbon fraction, starting the ethylene cooling system, switching to a mode of the demethanization unit, starting the subassemblies for hydration and isolation of the ethylene and propylene fractions, in order to reduce the length of the start up period and to reduce the ejection of gas to the burner, after starting the demethanizer in the steaming mode, starting the ethane and ethylene and propane and propylene towers, the ethane and ethylene and propane and propylene fractions are mixed before the hydration subassemblies with an H2 bearing gas for catalytic reforming and then the other units and subassemblies are started.

  12. Multi-criteria optimization for determining installation locations for the power-to-gas technologies

    Moskalenko, Natalia; Lombardi, Pio Alessandro; Komarnicki, Przemyslaw

    2014-01-01

    The steady rise of the integration of renewable energy sources (RES) has led to a re-examination of existing energy storage technologies as well as the development of new ones, e.g. power-to-gas (P2G) technology. This technology uses surplus of electricity from RES to create the synthetic natural gas, which can be stored for long periods of time, and thus it can significantly support the integration of RES into the existing power grid and extend a system transmission capacity, which is needed...

  13. Reduction of greenhouse gas emissions resulting from decreased losses in the conductors of an electrical installation

    Lobão, J.A.; Devezas, T.; Catalão, J.P.S.

    2014-01-01

    Highlights: • A new software application is provided in this paper. • The efficient investment in street lighting and industrial and domestic electrical equipment is analyzed. • The reduction of losses in the conductors of electrical installations is properly accounted for. • The reduction of CO 2 emitted into the atmosphere is also determined. - Abstract: The activities of the electricity sector in production and consumption have implications in almost all environmental problems of today. The main environmental impacts occur during the production of electricity, mainly due to the emission of air pollutants, which is directly linked to climate change that has been observed over time. Ambitious climate change mitigation requires significant changes in many economic sectors, in particular in the production and consumption of energy. Considering that the primary energy consumption has increased, doubling since the 1970s, and in particular the consumption of electricity has had a sharper increase, nearly quadrupling in the same period, all measures that can mitigate environmental impacts on both the supply and demand sides of electricity are of interest. This paper introduces a new software application that analyses efficient investment in street lighting and industrial and domestic electrical equipment, accounting for the reduction of losses in the conductors of electrical installations, which is usually neglected. It also determines the reduction of CO 2 emitted into the atmosphere, which contributes to the reduction of emissions of greenhouse gases from a country or particular product

  14. Gas Atomization Equipment Statement of Work and Specification for Engineering design, Fabrication, Testing, and Installation

    Boutaleb, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pluschkell, T. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-11-30

    The Gas Atomization Equipment will be used to fabricate metallic powder suitable for Powder Bed Fusion additive Manufacturing material to support Lawrence Livermore National Laboratory (LLNL) research and development. The project will modernize our capabilities to develop spherical reactive, refractory, and radioactive powders in the 10-75 μm diameter size range at LLNL.

  15. Consideration of consumer installation fees upon termination of concession contracts in the gas economy

    Schumacher, K.S.

    1995-01-01

    At the Fourth Conference of the Forum Institute on 18 and 19 January 1995 there was a motion to grant the electricity supply an exceptional status in takeover price negotiations in order to do justice to the cost-price coupling prescribed in that sector. This was intended to legitimatise the abandonment of all managerial, market-oriented methods of calculating the actual value of an electricity network. These ideas met with well-founded opposition of the same conference. In the gas economy cost-price coupling is less rigid because here price formation is largely determined by substitution competition with other energy carriers (mineral oil, district heating, electricity). In view of these circumstances the present article deals exclusively with the termination of gas concession contracts. Because of the affinity of Articles 9 and 10 of the General Terms of the Gas Supply to Article 9 and 10 of the General Terms of the Electricity Supply some of the thoughts presented here also apply to the electricity supply. However, the results found here for the gas economy cannot be transferred to the electricity economy without modification. (orig.) [de

  16. Tunisia- British gas intends to participate to the building of a combined cycle electric power plant

    Anon.

    1996-01-01

    Here is described the project to build a combined-cycle power plant in Tunisia, project in which the British Gas is interested. The transport, distribution, import and export of electricity should be controlled by the Tunisian society of electricity and gas. In the context of an agreement with Gec-Alsthom, the british company hopes to offer to build, and exploit the future power plant. (N.C.)

  17. Marine mammal sightings around oil and gas installations in the central North Sea

    Delefosse, Matthieu; Rahbek, Malene Louise; Roesen, Lars

    2017-01-01

    288 animals were reported between May 2013 and May 2016. A total of seven marine mammal species were identified, five cetaceans: harbour porpoise (Phocoena phocoena), minke whale (Balaenoptera acutorostrata), white-beaked dolphin (Lagenorhynchus albirostris), killer whale (Orcinus orca), pilot whales......Relatively little is known about the distribution and diversity of marine mammals around offshore anthropogenic structures. Wepresentresultsobtainedfromincidentalsightings ofmarinemammalsaroundoilandgasinstallationslocated200 kmoff the Danish coast. A total of 131 sightings corresponding to about...... (Globicephala spp.) and two species of pinnipeds: harbour (Phoca vitulina) and grey seals (Halichoerus grypus). The most sighted species were harbour porpoise (41%) and minke whale (31%). Relative counts and biodiversity of marine mammals observed around installations corresponded well with the expected...

  18. Assessment of technological solutions for removal of radium discharged to sea from offshore oil and gas installations

    Eriksen, Dag Oeistein [Primus.inter.pares AS, Kongsberggata 20, NO-0468 Oslo (Norway); Hylland, Ketil [University of Oslo (Norway); Andersen, Knut Inge [Statoil ASA (Norway); Sidhu, Rajdeep Singh [Institute for Energy Technology - IFE (Norway)

    2014-07-01

    On the Norwegian sector of the North-Sea the oil- and gas-producing fields Troll B and C are the main contributors to radium discharged to the sea (190 GBq/a {sup 226}Ra and 150 GBq/a {sup 228}Ra). Thus, to observe effects caused by the emission of radioactivity and to consider remedial action one should focus on these two installations. Both installations are now operated by Statoil. In a previous comprehensive study of the speciation of discharged radium the conclusion was that it is impossible to detect any effect from radiation doses. The incremental doses due to the emissions were found to be in the nSv-range. The study covered precipitation by sulfate in the sea water, absorption on organic and inorganic materials, uptake in cod eggs and in juvenile cod, effect on sediment living organisms, background levels of pelagic fish and in sediments, and modeling of the distribution in the water column as well the distribution along the coastal stream. Despite the lack of radiation effects, an assessment of possible technological solution for removal of the radium has been undertaken. Such methods must meet the severe requirements imposed by the oil recovery process at Troll B and C: High produced water rates (>1000 m{sup 3}/h), high salinity and content of water soluble carboxylic acids originating from the crude oil, in addition to a relatively high content of barium (3 550 tonnes/a). For implementation on an offshore installation the footprint and weight of the equipment would have to be as low as possible. It is also imperative that the radiation doses to operators are as low as possible. This puts strict requirements on the shielding of the absorbents accumulating {sup 226}Ra and {sup 228}Ra. No commercially available methods were identified, but one new conceptual method based on absorption of radium on barite has been proposed. Barite is also a good shielding material. Tests performed at Institute for Energy Technology show, however, that the kinetics of the

  19. Reliability Based assessment of buildings under earthquakes due to gas extraction

    Steenbergen, R.D.J.M.; Vrouwenvelder, A.C.W.M.

    2014-01-01

    In the northern part of the Netherlands over de last decades shallow earthquakes are induced due to large scale gas extraction from the Groningen gas field. Earthquakes occur due to the compaction of the reservoir rock, which leads to subsidence at surface and strain build-up in the reservoir rock

  20. Greenhouse gas emissions of pilot buildings in 2009-2011; Pilottikiinteistoejen kasvihuonekaasupaeaestoet vuosina 2009-2011

    Riihimaki, M.

    2012-07-01

    The Julia 2030 use of premises project sought to reduce the greenhouse gas emissions of selected pilot buildings by 10 per cent over the period from 2009 to 2011 by changing patterns of use. The project also provided an opportunity for further refinement of a climate calculator developed and maintained by WWF for reckoning greenhouse gas emissions of this kind. The use of premises project covered a total of 32 pilot buildings in Helsinki, Espoo, Vantaa, Kauniainen, Kirkkonummi and Kerava. These buildings included nurseries and schools, swimming baths, offices, multi-purpose activity buildings, depots, a sports hall and a health centre. The combined greenhouse gas emissions of the pilot buildings in 2011 amounted to 10,416 tCO{sub 2}e, which was 8 per cent lower than the total of 11,293 tCO{sub 2}e recorded in 2009. This means that the project fell slightly short of its targeted 10 per cent reduction in greenhouse gas emissions. The total greenhouse gas emissions of the pilot buildings adjusted for heating requirement amounted to 10,733 tCO{sub 2}e in 2011, which was about 7 per cent lower than in 2009. Reckoned on a per capita basis for employees or visitors, the total greenhouse gas emissions adjusted for heating requirement fell in 25 buildings, but increased in seven buildings over the period from 2009 to 2011. Particularly significant emission reductions were achieved in Vantaa, where all buildings were able to cut their emissions by between 9 and 45 per cent. The principal cause of greenhouse gas emissions in the pilot buildings was heating consumption, which also accounts for the increase in their unadjusted greenhouse gas emissions over the cold winters of 2009 and 2010. The second most important emission source in the pilot buildings was electricity consumption. Air travel contributed significantly to the overall greenhouse gas emissions of the pilot buildings used by employees taking work-related flights, whereas the contribution of paper consumption and

  1. The principles involved in building an optimum system of magnetic gas analyzers

    Tsai, A N; Sukhanov, S

    1980-01-01

    A short survey is given of magnetomechanical and thermo-magnetic gas analyzers for oxygen. It is noted that the principle of building magnetic gas analyzers that measure secondary phenomena has fact that disadvantages due to the fact that a gas analyzer uses galvanaomagnetic elements from Hall generators. The measurement range is 0-2% of the volume of 0/sub 2/ concentration, the accuracy class is 1 and the threshold sensitivity is .01 percent by volume.

  2. Radon gas inside historical buildings in the city of Cordoba

    Perez, R.; Germanier, A.; Rubio, M.; Sbarato, D.; Zappino, R.

    1998-01-01

    Full text: In this work measurements of the Radon ( 222 Rn) concentration in the inside of historical buildings which date back to the end of the 17th and the beginning of the 18th Centuries have been carried out in the city of Cordoba (Argentina). Meteorological factors such as room temperature and atmospheric pressure have not shown to affect, to a great extent, the results obtained. By comparing the concentration of 222 Rn in environments at different levels we inferred that the soil underlying the buildings does not represent an important source of 222 Rn. The main occurrence of the element was found in room walls, which shows that local building materials are an important source of 222 Rn. Among the materials used in these buildings are granitic rocks, and to a lesser extent, lime, sand and marble. The 222 Rn concentrations recorded in some of the rooms surveyed reach values which are close to the minimum intervene level set by international standards in 4pCi/l. The study of the effects of ventilation in the concentration of 222 Rn allows us to conclude that its values decrease to accepted levels by means of a natural and efficient ventilation of the rooms. (author) [es

  3. Temperature control of thermal-gas-dynamical installation in cleaning oil-well tubes

    Penner, V. A.; Martemyanov, D. B.; Pshenichnikova, V. V.

    2017-08-01

    The article provides the study results of cleaning oil-well tubes, the oil-well tube failure reasons for service by their types have been considered. The chemical method of cleaning oil-well tubes as the least expensive has been reviewed when acid solution moves to the interptube space mixing up with oil and liquidates paraffin and pitches deposits on the internal pipe surface. Except the chemical method of pipes cleaning the mechanical one was considered as well. Also the disadvantages -such as the low productivity of cleaning and design complexity- of this deposits removal method on the internal oil-well tube surface have been considered. An effective method for cleaning oil-well tubing from paraffin and pitches by the thermodynamic plant based on the aircraft engine has been introduced for the first time. The temperature distribution graph in the gas stream at the engine output has been given.

  4. Time-dependent analysis of dissolver off-gas cleaning installations in a reprocessing plant

    Nagel, K.; Furrer, J.; Becker, G.; Obrowski, W.; Seghal, Y.P.; Weymann, J.

    1983-01-01

    The iodine- and aerosol-filtering test facility PASSAT of the Nuclear Research Centre in Karlsruhe has been investigated using a method which allows time-dependent analyses under accident conditions. This method which is closely related to fault-tree analysis needs subdivision in barriers of the system, and their logical combination in a tree. The barriers have binary states: defect and intact. The defect state will be described by a fault tree, whereas the intact state includes dependences of a barrier operation on physical parameters. The intact state enables time-dependent calculations. Calculations have been done for iodine filtering, because the best known entrance data are given. Results demonstrate clearly that the amount of iodine released increases only if both heaters failed, which heat the off-gas from 30 0 C to 80 0 C and then to 130 0 C. Additionally the integrated amount of iodine released depends on time period between the failures of the heaters

  5. Lifecycle performance. Special issue on management and maintenance, hybrid ventilation concepts, installation-low buildings; Lifecycle performance. Themanummer over beheer en onderhoud, hybride ventilatieconcepten, installatie-arme gebouwen

    Thierauf, I. [Universiteit Utrecht, Utrecht (Netherlands); Kurvers, S.R.; Van den Ham, E.R.; Leijten, J.L. [Sectie Climate Design and Sustainability, Afdeling Architectural Engineering and Technology, Faculteit Bouwkunde, Technische Universiteit Delft TUD, Delft (Netherlands); Juricic, S. [Ecole National des Travaux Publics de l' Etat, Lyon (France); Jacobs, P. [Afdeling Energy and Comfort Systems, TNO, Delft (Netherlands); Versteeg, H. [LBP Sight, Nieuwegein (Netherlands); Van Loon, P.P.M. [Stichting Scholen van Morgen, Rotterdam (Netherlands); Hoek, H.C.; Van Eeden, H.; Nibbelink, J. [Collectief C-on, Haarlem (Netherlands); Veerman, J.; Maassen, W.H. [Royal Haskoning DHV, Nijmegen (Netherlands); Derksen, A.H.P. [ISSO, Rotterdam (Netherlands); Morren, K. [Universiteit Twente, Enschede (Netherlands)

    2012-12-15

    In 9 articles various aspects regarding the title topic are discussed: energy efficiency and user comfort, ventilation in new houses with balanced ventilation, the revised assessment for ventilation performance, air quality in school buildings, buildings with only a few installations, hybrid ventilation, the management and maintenance process, and future performance requirements [Dutch] In 9 artikelen wordt aandacht besteed aan diverse aspecten m.b.t. het titelonderwerp: energie-efficientie en gebruikerscomfort, ventilatie in nieuwbouwwoningen met balansventilatie, de herziene beoordelingsrichtlijn ventilatie prestatie, luchtkwaliteit in schoolgebouwen, installatie-arme gebouwen, hybride ventilatie, het beheer- en onderhoudsproces, en de toekomstige prestatie-eisen.

  6. Modelling and dynamic simulation of processes with 'MATLAB'. An application of a natural gas installation in a power plant

    Gonzalez-Bustamante, J.A.; Sala, J.M.; Lopez-Gonzalez, L.M.; Miguez, J.L.; Flores, I.

    2007-01-01

    In this paper, it is proposed to incorporate the analysis of the dynamic performance of the process into the design and engineering stage of projects as a means of analysing and resolving this type of problem. The following contributions are made with this objective in mind:(a)The barriers in the way of dynamic analysis are identified. (b)Software tools which make dynamic analysis accessible during the design and engineering phase of the project are proposed. To achieve this goal, modelling and mathematical simulation are used, with the following features: *strict modelling of mass, momentum and energy conservation equations as well as state equations, and *utilisation of the 'Matlab-Simulink' package as the base-software tool. (c)The procedure and tool proposed for dynamic analysis during the design phase should enable these studies to be carried out at a reasonable cost and time for regular industrial projects, and not just for large research projects or nuclear power plants. To complete this paper, we apply our method to a natural gas installation in a power plant. The model is applied to study the transients of a natural gas supply line to a steam-electric power plant. The results of the model have been validated with the actual data on the boiler trip obtained from the distributed control system of a steam-electric power plant

  7. Radioactivity in produced water from Norwegian oil and gas installations - concentrations, bioavailability and doses to marine biota

    Sidhu, R.; Eriksen, D. Oe.; Straalberg, E.; Iden, K. I.; Rye, H.; Hylland, K.; Ruus, A.; Roeyset, O.; Berntssen, M. H. G.

    2006-03-15

    Substantial amounts of produced water, containing elevated levels of radionuclides (mainly 226Ra and 228Ra) are discharged to the sea as a result of oil and gas production on the Norwegian Continental Shelf. So far no study has assessed the potential radiological effects on marine biota in connection with radionuclide discharges to the North Sea. The main objective of the project is to establish radiological safe discharge limits for radium, lead and polonium associated with other components in produced water from oil and gas installations on the Norwegian continental shelf. Preliminary results indicate that presence of added chemicals such as scale inhibitors in the produced water has a marked influence on the formation of radium and barium sulphates when produced water is mixed with sea water. Thus, the mobility and bio-availability of radium (and barium) may be larger than anticipated. Also, the bio-availability of radium may be increased due to presence of such chemicals, and this is presently being studied. (author) (tk)

  8. The Radon Gas in Underground Buildings in Clay Soils. The Plaza Balmis Shelter as a Paradigm.

    Rizo Maestre, Carlos; Echarri Iribarren, Víctor

    2018-05-17

    In healthy buildings, it is considered essential to quantify air quality. One of the most fashionable indicators is radon gas. To determine the presence of this element, which is harmful to health, in the environment, the composition of the soil is studied. The presence of radon gas within a building depends both on the terrain in which it is located and on the composition of the materials of which it is composed, and not as was previously believed, only by the composition of the soil (whether granitic or not). Many countries are currently studying this phenomenon, including Spain where the building regulations regarding the accumulation of radon gas, do not list in their technical codes, the maximum dose that can a building can hold so that it is not harmful to people and the measures to correct excessive accumulation. Therefore, once the possible existence of radon in any underground building has been verified, regardless of the characteristics of the soil, the importance of defining and unifying the regulations on different levels of radon in all architectural constructions is evident. Medical and health science agencies, including the World Health Organization, consider that radon gas is a very harmful element for people. This element, in its gaseous state, is radioactive and it is present in almost soils in which buildings are implanted. Granitic type soils present higher levels of radon gas. Non-granitic soils have traditionally been considered to have very low radon levels. However, this paper demonstrates the relevant presence of radon in non-granitic soils, specifically in clayey soils, by providing the results of research carried out in the underground air raid shelter at Balmis Square in Alicante (Spain). The results of the measurements of radon accumulation in the Plaza Balmis shelter are five times higher than those obtained in a similar ungrounded building. This research addresses the constructive typology of an under-ground building and the radon

  9. Methane emission from naturally ventilated livestock buildings can be determined from gas concentration measurements

    Bjerg, B; Zhang, Guoqiang; Madsen, J

    2012-01-01

    Determination of emission of contaminant gases as ammonia, methane, or laughing gas from natural ventilated livestock buildings with large opening is a challenge due to the large variations in gas concentration and air velocity in the openings. The close relation between calculated animal heat pr...... to investigate the influence of feed composition on methane emission in a relative large number of operating cattle buildings and consequently it can support a development towards reduced greenhouse gas emission from cattle production.......Determination of emission of contaminant gases as ammonia, methane, or laughing gas from natural ventilated livestock buildings with large opening is a challenge due to the large variations in gas concentration and air velocity in the openings. The close relation between calculated animal heat...... ventilated, 150 milking cow building. The results showed that the methane emission can be determined with much higher precision than ammonia or laughing gas emissions, and, for methane, relatively precise estimations can be based on measure periods as short as 3 h. This result makes it feasible...

  10. Risk-targeted safety distance of reinforced concrete buildings from natural-gas transmission pipelines

    Russo, Paola; Parisi, Fulvio

    2016-01-01

    Natural-gas pipeline accidents mostly result in major damage even to buildings located far away. Therefore, proper safety distances should be observed in land use planning to ensure target safety levels for both existing and new buildings. In this paper, a quantitative risk assessment procedure is presented for the estimation of the annual probability of direct structural damage to reinforced concrete buildings associated with high-pressure natural-gas pipeline explosions. The procedure is based on Monte Carlo simulation and takes into account physical features of blast generation and propagation, as well as damage to reinforced concrete columns. The natural-gas jet release process and the flammable cloud size are estimated through SLAB one-dimensional integral model incorporating a release rate model. The explosion effects are evaluated by a Multi-Energy Method. Damage to reinforced concrete columns is predicted by means of pressure–impulse diagrams. The conditional probability of damage was estimated at multiple pressure–impulse levels, allowing blast fragility surfaces to be derived at different performance limit states. Finally, blast risk was evaluated and allowed the estimation of minimum pipeline-to-building safety distances for risk-informed urban planning. The probabilistic procedure presented herein may be used for performance-based design/assessment of buildings and to define the path of new natural-gas pipeline networks. - Highlights: • The safety of buildings against blast loads due to pipeline accidents is assessed. • A probabilistic risk assessment procedure is presented for natural-gas pipelines. • The annual risk of collapse of reinforced concrete building columns is evaluated. • Monte Carlo simulation was carried out considering both pipeline and column features. • A risk-targeted safety distance is proposed for blast strength class 9.

  11. Power and energy saving in buildings by distributed generation based on gas-engine systems

    Arghandeh, R.; Amidpour, M.; Ghaffari, A. [Khaje Nasir Toosi Univ. of Technology, Tehran (Iran, Islamic Republic of). Joint Program of Energy Systems Engineering; Manchester Univ., Manchester (United Kingdom)

    2008-07-01

    Buildings consume high amounts of energy and produce high amounts of greenhouse gas (GHG) emissions. This paper discussed the use of gas cogeneration distributed generation (DG) technologies as a means of reducing energy consumption from buildings as well as energy losses from transmission lines in Iran. Energy sources and power generation systems were reviewed, and the economical benefits and energy savings resulting from the use of cogeneration systems were outlined. Actual rates of electricity consumption for Iran were estimated. Building power consumption was divided into the following 6 major sections: (1) lighting, (2) home appliances, (3) restaurant and cooking devices, (4) sports facilities, (5) utilities, and (6) electronics. Energy consumption criteria (ECC) and daily consumption charts (DCC) were used to plan and design the cogeneration systems. Energy balances, capital costs, and investment rates of return (IRR) were then calculated for 2 scenarios for a sample building. Results of the study showed that gas engine combined heat and power (CHP) DG systems are a reliable and economic technology for reducing energy consumption in buildings. The IRR of the CHP DG system for the sample building was achieved in 1 year. 13 refs., 10 tabs., 11 figs.

  12. Investigating and analysing the energy and environmental performance of an experimental green roof system installed in a nursery school building in Athens, Greece

    Santamouris, M.; Pavlou, C.; Doukas, P.; Synnefa, A.; Hatzibiros, A. [University of Athens, (Greece). Department of Physics, Division of Applied Physics, Laboratory of Meteorology; Mihalakakou, G. [University of Ioannina, Agrinion (Greece). Department of Environment and Natural Resources Management; Patargias, P. [University of Peloponnesus, Kalamata (Greece). Faculty of Human Sciences and Cultural Studies, Department of History, Archaeology and Cultural Heritage Management

    2007-09-15

    This paper deals with the experimental investigation and analysis of the energy and environmental performance of a green roof system installed in a nursery school building in Athens. The investigation was implemented in two phases. During the first phase, an experimental investigation of the green roof system efficiency was presented and analysed, while in the second one the energy savings was examined through a mathematical approach by calculating both the cooling and heating load for the summer and winter period for the whole building as well as for its top floor. The energy performance evaluation showed a significant reduction of the building's cooling load during summer. This reduction varied for the whole building in the range of 6-49% and for its last floor in the range of 12-87%. Moreover, the influence of the green roof system in the building's heating load was found insignificant, and this can be regarded a great advantage of the system as any interference in the building shell for the reduction of cooling load leads usually to the increase of its heating load. (author)

  13. Development of an installation for the production of high-purity hydrogen using the pressure-swing-adsorption process with coke-oven gas as feedstock

    Nakamura, M; Sugishita, M

    1986-04-01

    This paper describes how Nippon Steel developed a process for producing high-purity hydrogen using the PSA method with coke-oven gas as a feedstock. The process comprises a gas-compression and gas-cooling stage, a pre-treatment stage, an adsorption stage, a de-oxygenation stage and various control and maintenance devices, etc. The triple-tower plant constructed is the equivalent of a four-tower conventional installation, with a maximum capacity of around 10,000 Nm/sup 3//h. 1 tab., 14 figs., 3 refs.

  14. A multi-objective optimization model for energy-efficiency building envelope retrofitting plan with rooftop PV system installation and maintenance

    Fan, Yuling; Xia, Xiaohua

    2017-01-01

    Highlights: • A multi-objective optimization model for building envelope retrofit is presented. • Facility performance degradation and maintenance is built into the model. • A rooftop PV system is introduced to produce electricity. • Economic factors including net present value and payback period are considered. - Abstract: Retrofitting existing buildings with energy-efficient facilities is an effective method to improve their energy efficiency, especially for old buildings. A multi-objective optimization model for building envelope retrofitting is presented. Envelope components including windows, external walls and roofs are considered to be retrofitted. Installation of a rooftop solar panel system is also taken into consideration in this study. Rooftop solar panels are modeled with their degradation and a maintenance scheme is studied for sustainability of energy and its long-term effect on the retrofitting plan. The purpose is to make the best use of financial investment to maximize energy savings and economic benefits. In particular, net present value, the payback period and energy savings are taken as the main performance indicators of the retrofitting plan. The multi-objective optimization problem is formulated as a non-linear integer programming problem and solved by a weighted sum method. Results of applying the designed retrofitting plan to a 50-year-old building consisting of 66 apartments demonstrated the effectiveness of the proposed model.

  15. Study of Cycling Air-Cooling System with a Cold Accumulator for Micro Gas-Turbine Installations

    Ochkov, V. F.; Stepanova, T. A.; Katenev, G. M.; Tumanovskii, V. A.; Borisova, P. N.

    2018-05-01

    Using the cycling air-cooling systems of the CTIC type (Combustion Turbine Inlet Cooling) with a cold accumulator in a micro gas-turbine installation (micro-GTI) to preserve its capacity under the seasonal temperature rise of outside air is described. Water ice is used as the body-storage in the accumulators, and ice water (water at 0.5-1.0°C) is used as the body that cools air. The ice water circulates between the accumulator and the air-water heat exchanger. The cold accumulator model with renewable ice resources is considered. The model contains the heat-exchanging tube lattice-evaporator covered with ice. The lattice is cross-flowed with water. The criterion heat exchange equation that describes the process in the cold accumulator under consideration is presented. The calculations of duration of its active operation were performed. The dependence of cold accumulator service life on water circulation rate was evaluated. The adequacy of the design model was confirmed experimentally in the mock-up of the cold accumulator with a refrigerating machine periodically creating a 200 kg ice reserve in the reservoir-storage. The design model makes it possible to determine the weight of ice reserve of the discharged cold accumulator for cooling the cycle air in the operation of a C-30 type micro- GTI produced by the Capstone Company or micro-GTIs of other capacities. Recommendations for increasing the working capacity of cold accumulators of CTIC-systems of a micro-GTI were made.

  16. Problems of Gas Pressure Build-up in Casing String of UGS and Gas Wells

    Peter Sovius

    2006-10-01

    Full Text Available This paper consists of three basic parts. The opening part is a brief description of problems associated with the secondary untightness of UGS wells (Underground Gas Storages and gas wells generally.The main part of the paper is composed of some cases that we have met in our company. Solution proposals of various cases are also supplied in this part. Separate problem situations are described in terms of finding out an untight point and also a testing result and consequential removing of untightness.The conclusion includes knowledge summary that were taken by solution of complicatedsituations connected with well non-hermeticity.

  17. Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

    2017-06-19

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements. Simulations were completed under a 'peak day' sizing scenario with 183 gpd hot water loads in a Minnesota winter climate case. Full-year simulations were then completed in three climates (ranging from Phoenix to Minneapolis) for three hot water load scenarios (36, 57, and 96 gpd). Model projections indicate that the alternative hybrid offers an average 4.5% efficiency improvement relative to the 0.60 EF gas storage unit across all scenarios modeled. The alternative hybrid water heater evaluated does show promise, but the current low cost of natural gas across much of the country and the relatively small incremental efficiency improvement poses challenges in initially building a market demand for the product.

  18. Proposal for the award of an industrial support contract for the maintenance of and work on tertiary buildings at CERN, and operation of their installations

    2005-01-01

    This document concerns the award of a contract for maintenance of and work on tertiary (i.e. non-accelerator) buildings and operation of their installations. The Finance Committee is invited to agree to the negotiation of a contract with the consortium CEGELEC CENTRE EST (FR) â?" CEGELEC (CH) â?" G.T.M. (FR), the lowest bidder complying with the specification, for the provision of the maintenance of and work on tertiary buildings at CERN, and operation of their installations, for three years for a total amount not exceeding 9 346 650 euros (14 379 454 Swiss francs), not subject to revision until 1st January 2009, with options for additional services for an amount not exceeding 457 600 euros (704 000 Swiss francs), not subject to revision until 1st January 2009, bringing the total to an amount not exceeding 9 804 250 euros (15 083 454 Swiss francs), not subject to revision until 1st January 2009. The contract will include options for two one-year extensions beyond the initial three-year period.

  19. Legal provisions governing technical installations, especially regulations of the Building Law, Trade-and-Industry Law, and Atomic Energy Law

    Nicklisch, F.

    1984-01-01

    The author first shows the various legal regulation patterns of the German law system with regard to technical installations and in this context discusses the comprehensive clause method which refers to scientific-technical standards. This method is said to be an adequate means of achieving suitable results in the relationship between law and technology. However, three weak points can be seen: (1) The law system uses many different standards. (2) Due to uncertainty about the real meaning and content of these standards, it is not clear how these standards are defined. (3) This in practice puts up the question to what extent statutory works of technology are a suitable tool of making legal regulations more concrete, and whether they are to be given binding force. (HSCH) [de

  20. STUDSVIK's methods for treatment/free release of components and buildings structures from decommissioning of nuclear installations

    Krause, G.

    2005-01-01

    This paper will describe methods for treatment of retired, large, contaminated components from NPPs. The treatment includes transports, decontamination, segmentation, melting as well recycling of the metal in Sweden. Decontamination and free release of building strictures is also one of services which Studsvik provides for the nuclear industry. For this services different techniques are used for 'shaving' and subsequent measurements of the concrete surfaces. Since the mid of 1980-ies different procedures for decontamination and segmentation as well as pre- and post treatment have been developed and successively applied at Studsvik's melting facility in Sweden. The experience on this sector are permanent used for improvement and development of methods for treatment of both domestic and foreign large components like: heat exchangers, reactors vessel heads, turbine parts, steam generators and boilers. The high metal recycling rate is due to optimized production and results in extremely low percentage of secondary waste. The driving force is to maximize recycling rate of metal to the steel industry and to minimize the volume of the secondary waste and by that owner's costs for final storage in the national repositories. For decontamination of building structures several options are available using shaving or hammering tools to remove the contaminated concrete layers. This treatment is carried out in the closed circuit where removed dust is directly evacuated into the waste collection drums. During and after the decontamination process the treated and surrounding areas are free from dust and risk of cross contamination has been eliminated. The equipment capacity is up to 30 m2/h with simultaneous concrete removal of 3 mm at very high accuracy. It is not necessary of in-housing (tent, containment) of working area. The presentation will focus on methods, equipment used and experience in treatment of components and methods for decontamination of building structures

  1. Exergetic analysis of the heat pump installed in the Limmat school building in Zurich; Exergieanalyse der Waermepumpe im Schulhaus Limmat - Schlussbericht

    Friedl, M.

    2009-10-15

    In large buildings, heat pumps todays are only used in a small number of cases. In those rare cases, they are operated with synthetic working fluids and are mainly used for low temperature heating. Since January 2006, a heat pump with Propane as working fluid has been operating in a school building in Zuerich (Schulhaus Limmat), which provides space heating and hot water for the old building erected in 1909. As a heat source, a main channel of sewage is used, an ideal heat source, which is only rarely used nowadays. Hence, the installation has a pioneering role in many aspects and has been analysed in detail during the current project. During this project, the Propane heat pump in the Schulhaus Limmat as well as the hydraulic system have been analysed in respect to its exergetic losses. The heat pump has a seasonal performance factor of 2.7. The investigation has shown that the heat pump does not operate in an optimal way and that the hydraulic has room for improvement with respect to exergetic losses. In implementing the measures suggested in this report, the seasonal performance factor can be increased to about 4.4. (author)

  2. Building

    Seavy, Ryan

    2014-01-01

    Building for concrete is temporary. The building of wood and steel stands against the concrete to give form and then gives way, leaving a trace of its existence behind. Concrete is not a building material. One does not build with concrete. One builds for concrete. MARCH

  3. Gas and water permeability of concrete for reactor buildings small specimens

    Mills, R.H.

    1986-03-01

    The effect on permeability of artifical aging by drying shrinkage and by freeze-thaw was determined by observing mass transfer of gas and water under a pressure gradient. It was found that damage due to freeze-thaw was negligible but that cracking around aggregate caused by drying shrinkage resulted in significantly increased permeability to both gas and water. The absence of freeze-thaw damage was attributed to self-dessication. Since the concrete was not exposed to an external source of water, the chemical reaction was sustained by consumption of mixing water. The resulting air voids were, apparently, sufficient to absorb expansive pressures due to ice formation. The response to lateral prestress was different for cracked and uncracked concrete. Although, in all cases, increased prestress resulted in reduced leakage, the effect was stronger in cracked concrete. Mean pore diameter as determined by gas diffusion was not, however, substantially affected because the leakage in cracked concrete remained very low. Reinforcing steel did not have a great influence on permeability of small specimens. Gas transmission through concrete was strongly influenced by moisture content. Free moisture constituted a barrier to gas flow, acting as a virtual solid. This is important since aging of concrete results in reduced free moisture. Ultrasonic pulse velocity appeared to vary with moisture content and porosity of concrete in the same way as gas permeability and gave promise of being effective for in-situ monitoring of concrete in reactor buildings

  4. Investigating erosion of building materials used in an installation for pneumatic transport of coke breeze and coal

    Bandrowski, J.; Kot-Borkowska, Z.; Misztal, M.; Raczek, J.; Kaczmarzyk, G.

    1980-09-01

    This article investigates the influence of the following factors on erosion of building material used in pneumatic transport of coal and coke breeze: intensity of coal or coke breeze flow within the range of 47 to 120 kg/h for coke and 99 to 165 kg/h for coal; speed of solid material particles within the range 3.71 to 7.97 m/s for coke, and 3.30 to 7.58 m/s for coal; duration of the experiments 0.5 to 1.5 h for coke and 2.0 to 5.0 for coal; angle of inclination of the sample of building material 30 to 60 degrees for both coal and coke breeze. Three types of construction material used in pneumatic transport were tested: steel, concrete and chamotte bricks. Investigations show that concrete is characterized by the highest erosion, chamotte bricks by medium erosion and steel by the lowest erosion. As a result of mathematical processing of experimental data, empirical models of erosion of the three materials are constructed. (7 refs.)

  5. Measure Guideline. High Efficiency Natural Gas Furnaces

    Brand, L. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States); Rose, W. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States)

    2012-10-01

    This measure guideline covers installation of high-efficiency gas furnaces, including: when to install a high-efficiency gas furnace as a retrofit measure; how to identify and address risks; and the steps to be used in the selection and installation process. The guideline is written for Building America practitioners and HVAC contractors and installers. It includes a compilation of information provided by manufacturers, researchers, and the Department of Energy as well as recent research results from the Partnership for Advanced Residential Retrofit (PARR) Building America team.

  6. Measure Guideline: High Efficiency Natural Gas Furnaces

    Brand, L.; Rose, W.

    2012-10-01

    This Measure Guideline covers installation of high-efficiency gas furnaces. Topics covered include when to install a high-efficiency gas furnace as a retrofit measure, how to identify and address risks, and the steps to be used in the selection and installation process. The guideline is written for Building America practitioners and HVAC contractors and installers. It includes a compilation of information provided by manufacturers, researchers, and the Department of Energy as well as recent research results from the Partnership for Advanced Residential Retrofit (PARR) Building America team.

  7. Buildings interoperability landscape - Draft

    Hardin, Dave B. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Stephan, Eric G. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Wang, Weimin [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Corbin, Charles D. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States); Widergren, Steven E. [Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)

    2015-02-01

    Buildings are an integral part of our nation’s energy economy. The advancement in information and communications technology (ICT) has revolutionized energy management in industrial facilities and large commercial buildings. As ICT costs decrease and capabilities increase, buildings automation and energy management features are transforming the small-medium commercial and residential buildings sectors. A vision of a connected world in which equipment and systems within buildings coordinate with each other to efficiently meet their owners’ and occupants’ needs, and where buildings regularly transact business with other buildings and service providers (such as gas and electric service providers) is emerging. However, while the technology to support this collaboration has been demonstrated at various degrees of maturity, the integration frameworks and ecosystems of products that support the ability to easily install, maintain, and evolve building systems and their equipment components are struggling to nurture the fledging business propositions of their proponents.

  8. Mandatory reporting of greenhouse gas emissions from buildings: Stakeholders’ opinions in Hong Kong

    Lai, Joseph H.K.

    2014-01-01

    Mandatory reporting of greenhouse gas (GHG) emissions, which is intended to help combat global warming, has been increasingly implemented across the world. For buildings in Hong Kong, however, GHG reporting remains entirely voluntary even though the government has issued a set of guidelines to facilitate building owners and managers to quantify GHG emissions from buildings. Aimed at understanding stakeholders’ opinions on whether, and to what extent, the GHG reporting should be made mandatory, a study involving a questionnaire survey was carried out. Analysis of the opinions revealed that the majority supported making the reporting mandatory for office, hotel/hostel, and industrial buildings. Generally more support was received from those who were highly experienced, employees of non-government public organisations, academics/researchers, or qualified carbon/energy auditors. Their agreement on requiring reporting of activities under scopes 1 and 2 of the GHG Protocol was stronger than that for the scope 3 activities. Reporting of paper waste disposal attracted the weakest support. The reasons for not supporting the mandatory policy, including resource constraint and financial and knowledge barriers that confront the stakeholders, were identified. The findings of this study serve as reference for energy policy makers. - Highlights: • Majority supported mandatory reporting for office and hotel/hostel buildings. • More support was given for reporting of scopes 1 and 2 of the GHG Protocol. • Reporting for paper waste disposal received the weakest support. • Main hurdles were resource constraint and financial and knowledge barriers

  9. Impact of domestic and tertiary buildings heating by natural gas in the Italian context

    Aste, Niccolò; Del Pero, Claudio

    2012-01-01

    Natural Gas (NG) is commonly used for satisfying population needs for heating, domestic hot water production and cooking, particularly in countries where the price of electricity is high. Typically, NG is extensively distributed on urbanized territory and can be exploited by using different technologies. As a consequence, primary energy is usually consumed directly in buildings, allowing high efficiency conversion but also producing pollutants in urban areas. In this paper a comprehensive analysis on NG use in the Italian domestic and tertiary building sector has been carried out, in order to evaluate energy and environmental impact of this fuel on different climatic and geographical contexts, also considering the temporal fluctuation of consumption. The aim of the work is to trace a reliable and up-to-date scenario of NG employment for building heating in Italy, which is one of the EU countries where this source is more widely used. The study was carried out under the research program “Analysis and evaluation of the current status of the reduction measures of environmental impacts due to heating energy consumption in Italy”, funded by the Italian Ministry of Environment. The data presented are an essential basis for the development of building energy efficiency and consumption rationalization policies. - Highlights: ► Detailed assessment of natural gas consumption and emission for residential and tertiary buildings heating in Italy. ► Estimation of the average specific primary energy consumption for households heating in different climatic contexts. ► Nationwide, it is the first study on the whole country with this level of detail.

  10. The benefit of the Dutch Energy Investment Allowance (EIA) for high-efficiency installations in industrial buildings; EIA maakt hr-apparatuur voor bedrijfsgebouwen voordelig

    De Boer, A. [ed.

    1998-02-01

    Gas-fired condensing appliances for space heating of industrial buildings are more expensive than appliances that do not show a high efficiency. In many cases, however, it is still cheaper to invest in condensing appliances. Not only because of lower exploitation costs, but also because of the ISO-high-efficiency subsidy regulation (`ISO-hr`), the energy investment allowance (EIA) and the energy conservation fund. The technologies that are eligible for the EIA are listed in the `Energielijst` (energy list) for 1998

  11. Scenarios of high greenhouse gas emission reduction in transports and buildings by 2050

    Teissier, O.; Meunier, L.

    2008-01-01

    The authors report simulations of different environmental policy measures concerning transports and buildings in France. First, they review measures which may entail a reduction of greenhouse gas emissions, and comment their emission reduction potential and their implementation costs. These measures are then ranked, and only those presenting a significant potential and an economically and technologically feasibility are finally considered. Their impact is then simulated by using different models which are adapted to the both sectors and to time ranges. The obtained results are compared to those obtained with a calibrated trend scenario and with a 'factor 4' scenario

  12. Application of quality assurance guidelines to the high pressure gas system, building 331

    Hanel, S.

    1976-01-01

    Major improvements have been made to decrease the tritium release potential for LLL's tritium-handling facilities in Bldg. 331. Some of the major problems and solutions in designing and building the High Pressure Gas System, which was the first system to be rebuilt are described. To increase system safety, it was necessary to specify material and processes used in component manufacture, to inspect all materials and processes to ensure compliance with specifications, to use proper joint design, to use secondary containment in cases where specifications could not be met, and to exercise tighter control of operating procedures

  13. Seminar series on `Technical building installations`. The example of refrigeration technology for air conditioning plants. Practice-oriented advanced training at Technische Akademie Esslingen training centre. Seminar series on `Technical building installations`; Lehrgangsreihe ``Technische Gebaeudeausruestung``. Beispiel: Kaeltetechnik in Klimaanlagen. Praxisnahe Fortbildung am Weiterbildungszentrum Technische Akademie Esslingen. Lehrgangsreihe ``Technische Gebaeudeausruestung``

    Anon.

    1995-04-01

    The advanced training on ``Technical Building Installations`` at the Technische Akademie Esslingen has been held regularly over a period of 18 years now. The training lasts several days and comprises a total of 12 courses on the subjects: ventilation and air-conditioning, stages A-D; refrigeration, stage A; refrigeration in air conditioning glants; energy concepts for buildings and industry, stages A and B; heating in old and new buildings; sanitation, stages A and B; and, sanitation in old and new buildings. In the present article the structure of the training is illustrated for the example of refrigeration in air conditioning plants. The article also discusses questions concerning the assessment of the training and its benefit to the participants. (BWI) [Deutsch] Seit nunmehr 18 Jahren wird an der Technischen Akademie Esslingen TAE die mehrtaegige Fortbildungsveranstaltung ``Technische Gebaeudeausruestung`` durchgefuehrt. Insgesamt werden in diesem gesamten Themenkomplex 12 Lehrgaenge angeboten: Raumlufttechnik, Teil A-D; Kaeltetechnik Teil A - Kaeltetechnik in Klimaanlagen, Energiekonzepte fuer Gebaeude und Industrie, Teil A und B, Heiztechnik in Neu- und Altbauten, Sanitaertechnik Teil A und B. Am Beispiel des Themenbereiches Kaeltetechnik in Klimaanlagen wird die Lehrgangsausrichtung dargestellt. Ferner werden Fragen der Lehrgangsbewertung und der Nutzen fuer die Teilnehmer diskutiert. (BWI)

  14. Building Commissioning: A Golden Opportunity for Reducing Energy Costs and Greenhouse-gas Emissions

    Mills, Evan

    2009-07-16

    data are available revealed over 10,000 energy-related problems, resulting in 16% median whole-building energy savings in existing buildings and 13% in new construction, with payback time of 1.1 years and 4.2 years, respectively. In terms of other cost-benefit indicators, median benefit-cost ratios of 4.5 and 1.1, and cash-on-cash returns of 91% and 23% were attained for existing and new buildings, respectively. High-tech buildings were particularly cost-effective, and saved higher amounts of energy due to their energy-intensiveness. Projects with a comprehensive approach to commissioning attained nearly twice the overall median level of savings and five-times the savings of the least-thorough projects. It is noteworthy that virtually all existing building projects were cost-effective by each metric (0.4 years for the upper quartile and 2.4 years for the lower quartile), as were the majority of new-construction projects (1.5 years and 10.8 years, respectively). We also found high cost-effectiveness for each specific measure for which we have data. Contrary to a common perception, cost-effectiveness is often achieved even in smaller buildings. Thanks to energy savings valued more than the cost of the commissioning process, associated reductions in greenhouse gas emissions come at 'negative' cost. In fact, the median cost of conserved carbon is negative - -$110 per tonne for existing buildings and -$25/tonne for new construction - as compared with market prices for carbon trading and offsets in the +$10 to +$30/tonne range. Further enhancing the value of commissioning, its non-energy benefits surpass those of most other energy-management practices. Significant first-cost savings (e.g., through right-sizing of heating and cooling equipment) routinely offset at least a portion of commissioning costs - fully in some cases. When accounting for these benefits, the net median commissioning project cost was reduced by 49% on average, while in many cases they exceeded

  15. Risks in the transport and storage of liquefied natural gas. Sub-project 5-2: Investigation into building damage

    Gouwens, C.; Dragosavic, M.

    The large reserves and increasing use of natural gas as a source of energy have resulted in its storage and transport becoming an urgent problem. Since a liquid of the same mass occupies only a fraction of the volume of a gas, it is economical to store natural gas as a liquid. Liquefied natural gas is stored in insulated tanks and also carried by ship at a temperature of -160 C to 170 C. If a serious accident allows the LNG to escape, a gas cloud forms. The results of a possible explosion from such a gas cloud are studied. The development of a leak, escape and evaporation, size and propagation of the gas cloud, the explosive pressures to be expected and the results on the environment are investigated. Damage to buildings is examined making use of the preliminary conclusions of the other sub-projects and especially the explosive pressures.

  16. Patterns identification in supervisory systems of nuclear reactors installations and gas pipelines systems using self-organizing maps

    Doraskevicius Junior, Waldemar

    2005-01-01

    Self-Organizing Maps, SOM, of Kohonen were studied, implemented and tested with the aim of developing, for the energy branch, an effective tool especially for transient identification in nuclear reactors and for gas pipelines networks logistic supervision, by classifying operations and identifying transients or abnormalities. The digital system for the test was developed in Java platform, for the portability and scalability, and for belonging to free development platforms. The system, executed in personal computers, showed satisfactory results to aid in decision taking, by classifying IRIS (International Reactor Innovative and Secure) reactor operation conditions (data from simulator) and by classifying Southeast (owner: TRANSPETRO - Brazil) gas pipeline network. Various adaptations were needed for such business, as new topologies for the output layer of artificial neural network and particular preparation for the input data. (author)

  17. Magnetic compatibility of standard components for electrical installations: Computation of the background field and consequences on the design of the electrical distribution boards and control boards for the ITER Tokamak building

    Benfatto, I.; Bettini, P.; Cavinato, M.; Lorenzi, A. De; Hourtoule, J.; Serra, E.

    2005-01-01

    Inside the proposed Tokamak building, the ITER poloidal field magnet system would produce a stray magnetic field up to 70 mT. This is a very unusual environmental condition for electrical installation equipment and limited information is available on the magnetic compatibility of standard components for electrical distribution boards and control boards. Because this information is a necessary input for the design of the electrical installation inside the proposed ITER Tokamak building specific investigations have been carried out by the ITER European Participant Team. The paper reports on the computation of the background magnetic field map inside the ITER Tokamak building and the consequences on the design of the electrical installations of this building. The effects of the steel inside the building structure and the feasibility of magnetic shields for electrical distribution boards and control boards are also reported in the paper. The results of the test campaigns on the magnetic field compatibility of standard components for electrical distribution boards and control boards are reported in companion papers published in these proceedings

  18. Gas chromatographic study of degradation phenomena concerning building and cultural heritage materials

    Metaxa, E.; Agelakopoulou, T.; Bassiotis, I.; Karagianni, Ch.; Roubani-Kalantzopoulou, F.

    2009-01-01

    Air pollution influences all aspects of social and economical life nowadays. In order to investigate the impact of air pollution on materials of works of art, the method of Reversed Flow-Inverse Gas Chromatography has been selected. The presence of various atmospheric pollutants is studied on marbles, oxides-building materials and samples of authentic statues from the Greek Archaeological Museums of Kavala and of Philippi. The method leads to the determination of several physicochemical quantities and the characterization of the heterogeneous surfaces of these solids. Moreover, the influence of a second pollutant (synergistic effect) is examined. The structure, the properties and the behavior of the materials are examined by X-Ray Diffraction, Scanning Electron Microscopy and Raman Spectroscopy. Therefore, the precise measurement of the above mentioned quantities form the scientific basis for elucidation of the mechanism of the whole phenomenon of the degradation, thus providing a scientific platform to conservation procedures.

  19. Building-Resolved CFD Simulations for Greenhouse Gas Transport and Dispersion over Washington DC / Baltimore

    Prasad, K.; Lopez-Coto, I.; Ghosh, S.; Mueller, K.; Whetstone, J. R.

    2015-12-01

    The North-East Corridor project aims to use a top-down inversion methodology to quantify sources of Greenhouse Gas (GHG) emissions over urban domains such as Washington DC / Baltimore with high spatial and temporal resolution. Atmospheric transport of tracer gases from an emission source to a tower mounted receptor are usually conducted using the Weather Research and Forecasting (WRF) model. For such simulations, WRF employs a parameterized turbulence model and does not resolve the fine scale dynamics generated by the flow around buildings and communities comprising a large city. The NIST Fire Dynamics Simulator (FDS) is a computational fluid dynamics model that utilizes large eddy simulation methods to model flow around buildings at length scales much smaller than is practical with WRF. FDS has the potential to evaluate the impact of complex urban topography on near-field dispersion and mixing difficult to simulate with a mesoscale atmospheric model. Such capabilities may be important in determining urban GHG emissions using atmospheric measurements. A methodology has been developed to run FDS as a sub-grid scale model within a WRF simulation. The coupling is based on nudging the FDS flow field towards that computed by WRF, and is currently limited to one way coupling performed in an off-line mode. Using the coupled WRF / FDS model, NIST will investigate the effects of the urban canopy at horizontal resolutions of 10-20 m in a domain of 12 x 12 km. The coupled WRF-FDS simulations will be used to calculate the dispersion of tracer gases in the North-East Corridor and to evaluate the upwind areas that contribute to tower observations, referred to in the inversion community as influence functions. Results of this study will provide guidance regarding the importance of explicit simulations of urban atmospheric turbulence in obtaining accurate estimates of greenhouse gas emissions and transport.

  20. Air quality impact of a pair of 150 MW gas turbines pre-installation study on the Champagne-sur-Oise site

    Daganaud, A

    1994-12-31

    In the framework of a project for the installation of two gas turbines at the CHAMPAGNE-SUR-OISE power plant, EDF-CNET (Centre National de l`Equipement Thermique) is required to submit an impact report, which includes the present contribution. The purpose of the study was to perform atmospheric dispersion calculations to assess the sulphur dioxide and nitrogen oxide ground concentration levels liable to be incurred by such installations under specified operating conditions. Using the Gaussian dispersion model MULTIPOL, numerical simulations were performed over a 10-year period, based on the chronological stations. The ``fallout`` calculations were performed with an hourly time step over a 1200 point grid covering a 40 x 40 km zone around the plant. The resulting pollution is expressed for each point in terms of annual mean concentrations and daily and hourly mean concentration distributions. Main results are presented as pollution maps, which can then be easily checked against current regulatory values. Two scenarios were simulated : year-long full power operation, which is a fictitious bounding case scenario, and operation about 12 hours per day on 20 to 25 days per year, during the coldest winter periods, which is the most probable scenario. Pollution liable to result from this type of installation was found to be extremely slight. At the most exposed points of the site, the mean SO{sub 2} and NO{sub 2} concentrations obtained for all operating days were only 3{mu}g/m{sup 3} and hourly peaks amounted at most to a few tens of {mu}g/m{sup 3}. Such values remain well below the stipulated limits for these pollutants and the future guide values determined by the European authorities. Increasing the existing very low background level by this specific amount should consequently raise no problems. (Author). 18 figs., 3 annexes., 12 refs.

  1. Design/build/mockup of the Waste Isolation Pilot Plant gas generation experiment glovebox

    Rosenberg, K.E.; Benjamin, W.W.; Knight, C.J.; Michelbacher, J.A.

    1996-01-01

    A glovebox was designed, fabricated, and mocked-up for the WIPP Gas Generation Experiments (GGE) being conducted at ANL-W. GGE will determine the gas generation rates from materials in contact handled transuranic waste at likely long term repository temperature and pressure conditions. Since the customer's schedule did not permit time for performing R ampersand D of the support systems, designing the glovebox, and fabricating the glovebox in a serial fashion, a parallel approach was undertaken. As R ampersand D of the sampling system and other support systems was initiated, a specification was written concurrently for contracting a manufacturer to design and build the glovebox and support equipment. The contractor understood that the R ampersand D being performed at ANL-W would add additional functional requirements to the glovebox design. Initially, the contractor had sufficient information to design the glovebox shell. Once the shell design was approved, ANL-W built a full scale mockup of the shell out of plywood and metal framing; support systems were mocked up and resultant information was forwarded to the glovebox contractor to incorporate into the design. This approach resulted in a glovebox being delivered to ANL-W on schedule and within budget

  2. Tipping points for carbon dioxide and air pollution benefits: an energy systems analysis of natural gas verses electric technologies in the U.S. buildings sector

    Our analysis examines emission trade-offs between electricity and natural gas use in the buildings sector at the system level, including upstream emissions from the electric sector and natural gas mining emissions.

  3. Decree of the 6 May 2017 defining the conditions of additional remuneration of electricity produced by electricity production installations using wind mechanical energy with a maximum of 6 wind turbines. Decree of the 9 May 2014 defining purchase and additional remuneration conditions for the electricity produced by installations using mainly biogas produced by methanization of matters resulting from urban or industrial waste water treatment. Decree of the 9 May 2017 defining purchase conditions for electricity produced by installations implanted on building and using photovoltaic solar energy, with an installed power less than or equal to 100 kilowatts as those concerned at the 3. of the article D.314-15 of the Code of Energy, and located in continental metropolitan territory

    Royal, Segolene; Sapin, Michel

    2017-01-01

    This document gathers three legal texts which respectively define and eventually give elements and methods of calculation of conditions of additional remuneration or purchase of electricity produced by limited wind energy installations, by biogas-based electricity production installations, and by photovoltaic installations mounted on buildings

  4. Analyzing the Impact of Residential Building Attributes, Demographic and Behavioral Factors on Natural Gas Usage

    Livingston, Olga V.; Cort, Katherine A.

    2011-03-03

    study attempts to bridge that gap by analyzing behavioral data and investigate the applicability of additive nonparametric regression to this task. This study evaluates the impact of 31 regressors on residential natural gas usage. The regressors include weather, economic variables, demographic and behavioral characteristics, and building attributes related to energy use. In general, most of the regression results were in line with previous engineering and economic studies in this area. There were, however, some counterintuitive results, particularly with regard to thermostat controls and behaviors. There are a number of possible reasons for these counterintuitive results including the inability to control for regional climate variability due to the data sanitization (to prevent identification of respondents), inaccurate data caused by to self-reporting, and the fact that not all relevant behavioral variables were included in the data set, so we were not able to control for them in the study. The results of this analysis could be used as an in-sample prediction for approximating energy demand of a residential building whose characteristics are described by the regressors in this analysis, but a certain combination of their particular values does not exist in the real world. In addition, this study has potential applications for benefit-cost analysis of residential upgrades and retrofits under a fixed budget, because the results of this study contain information on how natural gas consumption might change once a particular characteristic or attribute is altered. Finally, the results of this study can help establish a relationship between natural gas consumption and changes in behavior of occupants.

  5. Decision 99-27 application 1029022 - Petro-Canada Oil and Gas application to install compressors at the Wilson Creek gas plant and at LSD 3-19-43-4 W5M, Wilson Creek Field

    1999-11-01

    Petro-Canada Oil and Gas applied to the Alberta Energy and Utilities Board (EUB) for approval to add two new compressors at the existing Wilson Creek sour gas processing facility, and to construct and operate a new sour gas compressor station in Alberta. The application was made pursuant to Section 26 (1)(b) of the Oil and Gas Conservation Act and Sections 7.001, 9.020, and 15.050 of the Oil and Gas Conservation Regulations. The applications and interventions were considered at a hearing at the Last West Hall, Rimbley, Alberta, commencing 7 April 1999. The issues concerning the applications were: the need for and location of the compressors, plant life, emissions, sulphur recovery, and noise. Petro-Canada will proceed with its commitment to local landowners to install and commission a sulphur recovery unit within 16 months of the date of this report. The sulphur recovery capability of the facility will meet guidelines defined in IL 88-13 for new sour gas plants based on either the current or an acceptable maximum daily inlet sulphur rate. Continuous-vent gas streams, including glycol regenerator, produced-water tank, and hydrocarbon condensate tank vents, at both the 3-29 compressor and at the Wilson Creek plant site will be burned in a flare or incinerator. Flare stacks at the 3-19 compressor site will be equipped with a suitable pilot and automatic igniter. The Wilson Creek plant flare system will be equipped with a suitable pilot, as well as automatic igniter and/or flame failure detection system. Petro-Canada will implement local ambient air quality monitoring and sound level monitoring consistent with its commitments to local landowners and regulatory requirements

  6. The analysis of energy consumption and greenhouse gas emissions of a large-scale commercial building in Shanghai, China

    Xin Wang

    2016-02-01

    Full Text Available Reasonable test, diagnosis, and analysis are meaningful for building energy efficiency retrofit and management. Energy consumption and greenhouse gas emission of a large-scale commercial building are described in this article. Basic information about energy consumption equipment is included in the investigation. Further diagnoses about the operational state of air-conditioning water systems, and ducted systems were implemented. Energy consumption decreased 200 kWh/m2 per year from 2007 to 2009 after energy-saving reconstruction in 2006. Next, a carbon audit was carried out; this comprised CO2 emission statistics associated with the energy use and categorization and structural analysis (categorization refers to energy categorization and structural analysis means the composition and its proportion relationship of all kinds of primary energy and secondary energy in energy production or consumption. Greenhouse gas emissions could be less than 150 kg/m2 per year from 2007 to 2009. An analysis of the correlation between CO2 emissions, building gross domestic product, and energy efficiency is also presented. This article makes an analysis on the energy utilization and energy-saving reconstruction of a public commercial building in Shanghai and then makes an analysis of carbon audit about greenhouse gas emissions related to energy utilization (it analyzes the status of building’s energy utilization and greenhouse gas emissions, to have a more comprehensive understanding on the internal relationship between energy consumption and its greenhouse gas emissions and provide researchful reference data for the development with reduction strategies of greenhouse gas emission in future building.

  7. Self-reported neurological symptoms in relation to CO emissions due to problem gas appliance installations in London: a cross-sectional survey

    Kreis Irene

    2008-07-01

    Full Text Available Abstract Background Previous research by the authors found evidence that up to 10% of particular household categories may be exposed to elevated carbon monoxide (CO concentrations from poor quality gas appliance installations. The literature suggests certain neurological symptoms are linked to exposure to low levels of CO. This paper addresses the hypothesis that certain self-reported neurological symptoms experienced by a householder are linked to an estimate of their CO exposure. Methods Between 27 April and 27 June 2006, 597 homes with a mains supply of natural gas were surveyed, mainly in old, urban areas of London. Qualified gas engineers tested all gas appliances (cooker, boiler, gas fire, and water heater and reported, according to the Gas Industry Unsafe Situations Procedure, appliances considered At Risk (AR, Immediately Dangerous (ID or Not to Current Standards (NCS. Five exposure risk categories were defined based on measurement of CO emitted by the appliance, its features and its use, with "high or very high" exposure category where occupants were considered likely to be exposed to levels greater than 26 ppm for one hour. The prevalence of symptoms at each level of exposure was compared with that at lowest level of exposure. Results Of the households, 6% were assessed as having a "high or very high" risk of exposure to CO. Of the individuals, 9% reported at least one neurological symptom. There was a statistically significant association between "high or very high" exposure risk to CO and self-reported symptoms compared to "no exposure" likelihood, for households not in receipt of benefit, controlling for "number of residents" and presence of pensioners, OR = 3.23 (95%CI: 1.28, 8.15. Risk ratios across all categories of exposure likelihood indicate a dose-response pattern. Those households in receipt of benefit showed no dose-response pattern. Conclusion This study found an association between risk of CO exposure at low concentration

  8. Sizewell 'B' cable installation

    Gemmell, D.R.

    1992-01-01

    N G Bailey and Co. Ltd., UK were awarded the contract for the procurement, manufacture, works testing, works finishing, supply, delivery, off-loading, storage, installation, site finishing, preservation, setting to work and site testing of the following; the main cable installation throughout the Station including the addition of the Radioactive Waste Building, earthing and lightning protection installation, cable supporting steelwork and carriers and glanding and termination of cables. The cabling installation comprises power distribution, control and instrumentation cabling including all the associated cabling accessories, terminal boxes and similar components. The way that the contract was set-up, awarded and is now being carried out is described. Planning and industrial relations have been key features of the contract. (Author)

  9. Modelling and dynamic simulation of processes with 'MATLAB'. An application of a natural gas installation in a power plant

    Gonzalez-Bustamante, J.A.; Sala, J.M.; Flores, I. [Escuela Superior de Ingenieros Industriales de Bilbao, Universidad del Pais Vasco, Alameda de Urquijo, s/n 48013 Bilbao (Bizkaia) (Spain); Lopez-Gonzalez, L.M. [Escuela Tecnica Superior de Ingenieria Industrial, Universidad de La Rioja, C/ Luis de Ulloa, 20. E 26004 Logrono (La Rioja) (Spain); Miguez, J.L. [Universidad de Vigo, Escuela Tecnica Superior de Ingenieros Industriales, C/Lagoas-Marcosende, s/n 36200 Vigo (Pontevedra) (Spain)

    2007-07-15

    In this paper, it is proposed to incorporate the analysis of the dynamic performance of the process into the design and engineering stage of projects as a means of analysing and resolving this type of problem. The following contributions are made with this objective in mind:(a)The barriers in the way of dynamic analysis are identified. (b)Software tools which make dynamic analysis accessible during the design and engineering phase of the project are proposed. To achieve this goal, modelling and mathematical simulation are used, with the following features: circle strict modelling of mass, momentum and energy conservation equations as well as state equations, and circle utilisation of the 'Matlab-Simulink' package as the base-software tool. (c)The procedure and tool proposed for dynamic analysis during the design phase should enable these studies to be carried out at a reasonable cost and time for regular industrial projects, and not just for large research projects or nuclear power plants. To complete this paper, we apply our method to a natural gas installation in a power plant. The model is applied to study the transients of a natural gas supply line to a steam-electric power plant. The results of the model have been validated with the actual data on the boiler trip obtained from the distributed control system of a steam-electric power plant. (author)

  10. Impact of future urban form on the potential to reduce greenhouse gas emissions from residential, commercial and public buildings in Utsunomiya, Japan

    Ishii, Satoshi; Tabushi, Shoichi; Aramaki, Toshiya; Hanaki, Keisuke

    2010-01-01

    Energy-saving technologies' applicability to making cities more environmentally sustainable can be strongly influenced by the city's form, building uses and their density pattern. Technological developments have clearly shown specific urban forms to be more conducive to installing certain mitigation technologies. In this study, the capacity for implementation and impacts on energy savings and subsequent greenhouse gas (GHG) reduction potential of mitigation technologies such as photovoltaic cells (PV) and combined heat and power (CHP) technologies were analysed with respect to three potential urban forms (high density centralised, medium density averaged and low density de-centralized) for Utsunomiya City, Japan. Given current building use patterns, scenarios for 2030 and 2050, showed the medium density averaged form, which benefits from both PV and CHP technologies, to outperform the other forms, resulting in an energy savings and GHG reduction potential of 27.6% in 2030 and 67.6% in 2050. Interestingly, GHG reduction in 2050 was primarily attributable to PV, while CHP technology had the greater influence in 2030. Despite the limitation of the analysis, the study provides a useful insight, highlighting the relationship between urban forms and GHG reduction potential by two energy-saving technologies.

  11. Installing Omeka

    Jonathan Reeve

    2016-07-01

    Full Text Available Omeka.net is a useful service for Omeka beginners, but there are a few reasons why you might want to install your own copy of Omeka. Reasons include: * Upgrades. By installing Omeka yourself, you can use the latest versions of Omeka as soon as they’re released, without having to wait for Omeka.net to upgrade their system. * Plugins and themes. You can install any plugin or theme you want, without being restricted to those provided by Omeka.net. * Customizations. You can buy a custom domain name, and customize your code to achieve your desired functionality. * Control. You have control over your own backups, and you can update the server yourself so that its security is always up-to-date. * Price. There are many low-cost Virtual Private Servers (VPSs now, some of which cost only $5 per month. * Storage. Many shared hosting providers now offer unlimited storage. This is useful if you have a large media library. In this tutorial, we’ll be entering a few commands on the command line. This tutorial assumes no prior knowledge of the command line, but if you want a concise primer, consult the Programming Historian introduction to BASH. There are other ways of installing Omeka, of course, some using exclusively GUI tools. Some hosting providers even offer “one-click installs” via their control panels. Many of those methods, however, will install older versions of Omeka which are then harder to upgrade and maintain. The method outlined below may not be the easiest way to install Omeka, but it will give you some good practice with using the command line, which is a skill that will be useful if you want to manually upgrade your install, or manually install other web frameworks. (For example, this installation method is very similar to WordPress’s “Five-Minute Install”. There are four steps to this process, and it should take about an hour.

  12. Coupling of WRF and Building-resolved CFD Simulations for Greenhouse Gas Transport and Dispersion

    Prasad, K.; Hu, H.; McDermott, R.; Lopez-Coto, I.; Davis, K. J.; Whetstone, J. R.; Lauvaux, T.

    2014-12-01

    The Indianapolis Flux Experiment (INFLUX) aims to use a top-down inversion methodology to quantify sources of Greenhouse Gas (GHG) emissions over an urban domain with high spatial and temporal resolution. Atmospheric transport of tracer gases from an emission source to a tower mounted receptor are usually conducted using the Weather Research and Forecasting (WRF) model. WRF is used extensively in the atmospheric community to simulate mesoscale atmospheric transport. For such simulations, WRF employs a parameterized turbulence model and does not resolve the fine scale dynamics that are generated by the flow around buildings and communities that are part of a large city. Since the model domain includes the city of Indianapolis, much of the flow of interest is over an urban topography. The NIST Fire Dynamics Simulator (FDS) is a computational fluid dynamics model to perform large eddy simulations of flow around buildings, but it has not been nested within a larger-scale atmospheric transport model such as WRF. FDS has the potential to evaluate the impact of complex urban topography on near-field dispersion and mixing that cannot be simulated with a mesoscale atmospheric model, and which may be important to determining urban GHG emissions using atmospheric measurements. A methodology has been developed to run FDS as a sub-grid scale model within a WRF simulation. The coupling is based on nudging the FDS flow field towards the one computed by WRF, and is currently limited to one way coupling performed in an off-line mode. Using the coupled WRF / FDS model, NIST will investigate the effects of the urban canopy at horizontal resolutions of 2-10 m. The coupled WRF-FDS simulations will be used to calculate the dispersion of tracer gases in an urban domain and to evaluate the upwind areas that contribute to tower observations, referred to in the inversion community as influence functions. Predicted mixing ratios will be compared with tower measurements and WRF simulations

  13. Sector trends and driving forces of global energy use and greenhouse gas emissions: focus in industry and buildings

    Price, Lynn; Worrell, Ernst; Khrushch, Marta

    1999-09-01

    Disaggregation of sectoral energy use and greenhouse gas emissions trends reveals striking differences between sectors and regions of the world. Understanding key driving forces in the energy end-use sectors provides insights for development of projections of future greenhouse gas emissions. This report examines global and regional historical trends in energy use and carbon emissions in the industrial, buildings, transport, and agriculture sectors, with a more detailed focus on industry and buildings. Activity and economic drivers as well as trends in energy and carbon intensity are evaluated. The authors show that macro-economic indicators, such as GDP, are insufficient for comprehending trends and driving forces at the sectoral level. These indicators need to be supplemented with sector-specific information for a more complete understanding of future energy use and greenhouse gas emissions.

  14. Sector trends and driving forces of global energy use and greenhouse gas emissions: focus in industry and buildings

    Price, Lynn; Worrell, Ernst; Khrushch, Marta

    1999-01-01

    Disaggregation of sectoral energy use and greenhouse gas emissions trends reveals striking differences between sectors and regions of the world. Understanding key driving forces in the energy end-use sectors provides insights for development of projections of future greenhouse gas emissions. This report examines global and regional historical trends in energy use and carbon emissions in the industrial, buildings, transport, and agriculture sectors, with a more detailed focus on industry and buildings. Activity and economic drivers as well as trends in energy and carbon intensity are evaluated. The authors show that macro-economic indicators, such as GDP, are insufficient for comprehending trends and driving forces at the sectoral level. These indicators need to be supplemented with sector-specific information for a more complete understanding of future energy use and greenhouse gas emissions

  15. Control of Greenhouse Gas Emissions by Optimal DER Technology Investment and Energy Management in Zero-Net-Energy Buildings

    Stadler, Michael; Siddiqui, Afzal; Marnay, Chris; Aki, Hirohisa; Lai, Judy

    2009-01-01

    The U.S. Department of Energy has launched the commercial building initiative (CBI) in pursuit of its research goal of achieving zero-net-energy commercial buildings (ZNEB), i.e. ones that produce as much energy as they use. Its objective is to make these buildings marketable by 2025 such that they minimize their energy use through cutting-edge, energy-efficiency technologies and meet their remaining energy needs through on-site renewable energy generation. This paper examines how such buildings may be implemented within the context of a cost- or CO2-minimizing microgrid that is able to adopt and operate various technologies: photovoltaic modules (PV) and other on-site generation, heat exchangers, solar thermal collectors, absorption chillers, and passive/demand-response technologies. A mixed-integer linear program (MILP) that has a multi-criteria objective function is used. The objective is minimization of a weighted average of the building's annual energy costs and CO2 emissions. The MILP's constraints ensure energy balance and capacity limits. In addition, constraining the building's energy consumed to equal its energy exports enables us to explore how energy sales and demand-response measures may enable compliance with the ZNEB objective. Using a commercial test site in northernCalifornia with existing tariff rates and technology data, we find that a ZNEB requires ample PV capacity installed to ensure electricity sales during the day. This is complemented by investment in energy-efficient combined heat and power (CHP) equipment, while occasional demand response shaves energy consumption. A large amount of storage is also adopted, which may be impractical. Nevertheless, it shows the nature of the solutions and costs necessary to achieve a ZNEB. Additionally, the ZNEB approach does not necessary lead to zero-carbon (ZC) buildings as is frequently argued. We also show a multi-objective frontier for the CA example, whichallows us to estimate the needed technologies

  16. Methyl chloride via oxyhydrochlorination of methane: A building block for chemicals and fuels from natural gas

    Benson, R.L.; Brown, S.S.D.; Ferguson, S.P.; Jarvis, R.F. Jr. [Dow Corning Corp., Carrollton, KY (United States)

    1995-12-31

    The objectives of this program are to (a) develop a process for converting natural gas to methyl chloride via an oxyhydrochlorination route using highly selective, stable catalysts in a fixed-bed, (b) design a reactor capable of removing the large amount of heat generated in the process so as to control the reaction, (c) develop a recovery system capable of removing the methyl chloride from the product stream and (d) determine the economics and commercial viability of the process. The general approach has been as follows: (a) design and build a laboratory scale reactor, (b) define and synthesize suitable OHC catalysts for evaluation, (c) select first generation OHC catalyst for Process Development Unit (PDU) trials, (d) design, construct and startup PDU, (e) evaluate packed bed reactor design, (f) optimize process, in particular, product recovery operations, (g) determine economics of process, (h) complete preliminary engineering design for Phase II and (i) make scale-up decision and formulate business plan for Phase II. Conclusions regarding process development and catalyst development are presented.

  17. Building integrated photovoltaics

    Ritzen, M.J.; Vroon, Z.A.E.P.; Geurts, C.P.W.; Reinders, Angèle; Verlinden, Pierre; Sark, Wilfried; Freundlich, Alexandre

    2017-01-01

    Photovoltaic (PV) installations can be realized in different situations and on different scales, such as at a building level. PV installations at the building level can either be added to the building envelope, which is called building added PV (BAPV), or they can be integrated into the building

  18. The radon gas at the context of legislation on the quality of internal air in buildings - the Portuguese experience

    Pinto, Paulo G.A.N.; Pereira, Alcides J.S.C.; Neves, Luis J.P.F.

    2011-01-01

    Radon gas has been recognized as an important environmental risk factor, especially when found in high concentrations inside buildings, and is currently classified by the World Health Organization as a carcinogen type 1. In this context, there is legislation in Portugal since 2006 that sets limits to its concentration in indoor air. The aim of this work was to synthesize the existing legislation with focus on the sampling and analysis. Some statistical data about the measurements obtained in the Natural Radioactivity Laboratory, of the Department of Earth Sciences, of the University of Coimbra are presented, and discussed in the context of the National Energy Certification of Buildings System

  19. Installation Art

    Petersen, Anne Ring

    Despite its large and growing popularity – to say nothing of its near-ubiquity in the world’s art scenes and international exhibitions of contemporary art –installation art remains a form whose artistic vocabulary and conceptual basis have rarely been subjected to thorough critical examination....... In Installation Art: Between Image and Stage, Anne Ring Petersen aims to change that. She begins by exploring how installation art developed into an interdisciplinary genre in the 1960s, and how its intertwining of the visual and the performative has acted as a catalyst for the generation of new artistic...... phenomena. It investigates how it became one of today’s most widely used art forms, increasingly expanding into consumer, popular and urban cultures, where installation’s often spectacular appearance ensures that it meets contemporary demands for sense-provoking and immersive cultural experiences. The main...

  20. Installation Art

    Petersen, Anne Ring

    . In Installation Art: Between Image and Stage, Anne Ring Petersen aims to change that. She begins by exploring how installation art developed into an interdisciplinary genre in the 1960s, and how its intertwining of the visual and the performative has acted as a catalyst for the generation of new artistic......Despite its large and growing popularity – to say nothing of its near-ubiquity in the world’s art scenes and international exhibitions of contemporary art –installation art remains a form whose artistic vocabulary and conceptual basis have rarely been subjected to thorough critical examination...... phenomena. It investigates how it became one of today’s most widely used art forms, increasingly expanding into consumer, popular and urban cultures, where installation’s often spectacular appearance ensures that it meets contemporary demands for sense-provoking and immersive cultural experiences. The main...

  1. Border installations

    Lenaerts, Koen

    1988-01-01

    Border installations cover all nuclear plants located near the border with a neighbouring state. However, the actual distance depends on the context. The distance can vary considerably. Also the prohibition on siting near a heavily populated area also defines the actual distance variably. The distance criteria may be modified by other factors of topography, prevailing climate and so on. Various examples which illustrate the problems are given. For example, the Creys-Melville nuclear power plant is 80km from Geneva and the Cattonam installation is 12km from the French border with Luxembourg and Germany. The Cattenom case is explained and the legal position within the European Institutions is discussed. The French licensing procedures for nuclear power stations are described with special reference to the Cattenom power plant. Border installations are discussed in the context of European Community Law and Public International Law. (U.K.)

  2. Influence of flue gas desulfurization (FGD) installations on emission characteristics of PM2.5 from coal-fired power plants equipped with selective catalytic reduction (SCR).

    Li, Zhen; Jiang, Jingkun; Ma, Zizhen; Fajardo, Oscar A; Deng, Jianguo; Duan, Lei

    2017-11-01

    Flue gas desulfurization (FGD) and selective catalytic reduction (SCR) technologies have been widely used to control the emissions of sulphur dioxide (SO 2 ) and nitrogen oxides (NO X ) from coal-fired power plants (CFPPs). Field measurements of emission characteristics of four conventional CFPPs indicated a significant increase in particulate ionic species, increasing PM 2.5 emission with FGD and SCR installations. The mean concentrations of PM 2.5 from all CFPPs tested were 3.79 ± 1.37 mg/m 3 and 5.02 ± 1.73 mg/m 3 at the FGD inlet and outlet, respectively, and the corresponding contributions of ionic species were 19.1 ± 7.7% and 38.2 ± 7.8%, respectively. The FGD was found to enhance the conversion of NH 3 slip from the SCR to NH 4 + in the PM 2.5 , together with the conversion of SO 2 to SO 4 2- , and increased the primary NH 4 + and SO 4 2- aerosol emissions by approximately 18.9 and 4.2 times, respectively. This adverse effect should be considered when updating the emission inventory of CFPPs and should draw the attention of policy-makers for future air pollution control. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Rebuilding of the Altermatt hydropower installation in Frauenfeld, Switzerland - Building permission and implementation project; Werkbetriebe Frauenfeld: Neubau Wasserkraftwerk Altermatt-Frauenfeld - Konzessions- und Bauprojekt. Schlussbericht

    Hintermann, M.

    2008-04-15

    This illustrated final report elaborated for the Swiss Federal Office of Energy (SFOE) takes a look at a project concerning the rebuilding of the existing Altermatt hydropower station in Frauenfeld, Switzerland. The history of the installation, built in 1860 and put out of service in the 1980s, is briefly discussed. The project for the reactivation of the location with a new hydropower station is discussed and various studies made concerning the location are examined. Figures on the water flow to be expected are presented and the concept behind the project is discussed, as are details such as water levels and installations that will help fish and beavers get past the power station's dam. The electromechanical installations of the 120 kW power station are briefly described. Environmental aspects are also discussed and figures are quoted on the energy production to be expected and the costs involved.

  4. A stochastic optimization approach to reduce greenhouse gas emissions from buildings and transportation

    Karan, Ebrahim; Asadi, Somayeh; Ntaimo, Lewis

    2016-01-01

    The magnitude of building- and transportation-related GHG (greenhouse gas) emissions makes the adoption of all-EVs (electric vehicles) powered with renewable power as one of the most effective strategies to reduce emission of GHGs. This paper formulates the problem of GHG mitigation strategy under uncertain conditions and optimizes the strategies in which EVs are powered by solar energy. Under a pre-specified budget, the objective is to determine the type of EV and power generation capacity of the solar system in such a way as to maximize GHG emissions reductions. The model supports the three primary solar systems: off-grid, grid-tied, and hybrid. First, a stochastic optimization model using probability distributions of stochastic variables and EV and solar system specifications is developed. The model is then validated by comparing the estimated values of the optimal strategies and actual values. It is found that the mitigation strategies in which EVs are powered by a hybrid solar system lead to the best cost-expected reduction of CO_2 emissions ratio. The results show an accuracy of about 4% for mitigation strategies in which EVs are powered by a grid-tied or hybrid solar system and 11% when applied to estimate the CO_2 emissions reductions of an off-grid system. - Highlights: • The problem of GHG mitigation is formulated as a stochastic optimization problem. • The objective is to maximize CO_2 emissions reductions within a specified budget. • The stochastic model is validated using actual data. • The results show an estimation accuracy of 4–11%.

  5. Nuclear installations

    2001-01-01

    This document presents the fulfilling of the Brazilian obligations under the Convention on Nuclear Safety. The Chapter 2 of the document contains some details about the existing Brazilian nuclear installations. Also, safety improvements at Angra 1 and aspects of Angra 2 and 3 are reported

  6. Nuclear installations

    1998-01-01

    This document presents the fulfilling of the Brazilian obligations under the Convention on Nuclear Safety. The Chapter 2 of the document contains some details about the existing Brazilian nuclear installations. Also, safety improvements at Angra 1 and aspects of Angra 2 and 3 are reported

  7. Experimental and Numerical Investigation of the Tracer Gas Methodology in the Case of a Naturally Cross-Ventilated Building

    Nikolopoulos, Nikos; Nikolopoulos, Aristeidis; Larsen, Tine Steen

    2012-01-01

    The paper presents the investigation of a naturally cross – ventilated building using both experimental and numerical methods with the parameters being the free-stream and the incidence angle of the wind to the openings of the building. The experimental methodology calculates the air change rate......, focusing on the time dependent character of the induced flow field. The numerical results are compared with corresponding experimental data for the three aforementioned experimental methodologies in the case of a full scale building inside a wind-tunnel. The numerical investigation reveals that for large...... based either on measurements of the inlet velocity profile, the outlet velocity profile or the descending rate of the tracer gas concentration using the decay method. The numerical investigation is based on the solution of the governing Navier-Stokes equations in their full three dimensional expression...

  8. Automated installation methods for photovoltaic arrays

    Briggs, R.; Daniels, A.; Greenaway, R.; Oster, J., Jr.; Racki, D.; Stoeltzing, R.

    1982-11-01

    Since installation expenses constitute a substantial portion of the cost of a large photovoltaic power system, methods for reduction of these costs were investigated. The installation of the photovoltaic arrays includes all areas, starting with site preparation (i.e., trenching, wiring, drainage, foundation installation, lightning protection, grounding and installation of the panel) and concluding with the termination of the bus at the power conditioner building. To identify the optimum combination of standard installation procedures and automated/mechanized techniques, the installation process was investigated including the equipment and hardware available, the photovoltaic array structure systems and interfaces, and the array field and site characteristics. Preliminary designs of hardware for both the standard installation method, the automated/mechanized method, and a mix of standard installation procedures and mechanized procedures were identified to determine which process effectively reduced installation costs. In addition, costs associated with each type of installation method and with the design, development and fabrication of new installation hardware were generated.

  9. Parameter design for a phase change material board installed on the inner surface of building exterior envelopes for cooling in China

    Sun, Xiaoqin; Zhang, Quan; Medina, Mario A.; Lee, Kyoung Ok; Liao, Shuguang

    2016-01-01

    Highlights: • Phase change material (PCM) boards were simulated in building envelopes. • The buildings were located in four cities with different climatic conditions. • Energy and mass efficiency was proposed to evaluate utilization of PCM board. • The optimal melting temperature increased with increasing mean air temperature. - Abstract: Phase change materials (PCMs) can be used for building envelope thermal management and for energy conservation because of their potential to absorb and release large amounts of heat with small wall temperature variations. In this paper, the heat transfer theory of a PCM board used for building envelopes is presented, together with a mathematical model based on the moving heat-source method. It was found that the model accurately predicted the position of the solid–liquid interface in time and space, comparing with the published data. Energy and mass efficiency (EME) was proposed to evaluate the energy efficiency of PCM boards in office buildings located in various climatic regions in China for cooling. The influences on EME of parameters, including melting temperature of PCM, PCM board thickness and the heat transfer coefficient of building envelope, were analyzed. The optimal melting temperatures of PCM board, which resulted in the peak EME, in office building were 24.1 °C in Shenyang, 25.0 °C in Kunming, 25.3 °C in Zhengzhou and 25.5 °C Changsha, respectively. The EME increased with the increasing heat transfer coefficient of building envelope. For the city of Changsha with higher outdoor air temperature, none of the PCM boards modeled contributed effectively.

  10. PHYSICO-CHEMICAL ANALYSIS OF THE WASTE FROM INSTALLATION OF SEMI-DRY FLUE GAS DESULFURIZATION OF INDUSTRIAL CHP PLANT IN JANIKOWO

    Marta Plaskacz-Dziuba

    2014-10-01

    Full Text Available The paper presents results of the analysis of waste from semi-dry flue gas desulphurisation installation called Integrated Novel Desulphurisation (NID. A comprehensive analysis of the physicochemical properties was conducted, including analyzes of the content of ions SO32- and SO42- (relating to 2CaSO3·H2O i CaSO4·2H2O, moisture, SiO2 and R2O3 and SEM-EDX analysis. The original method for the determination of sulphates (IV using a potentiometric titrator was designed. Determined that the main component of both studied wastes was 2CaSO3·H2O, and its content is for NID 1 – 41,24±0,63%, for NID 2 – 45,53±0,33%. The content of CaSO4·2H2O, which was determined by gravimetric method amounted for the NID 1 – 8,92±0,12%, for the NID 2 – 8,27±0,08%. The moisture content for both tested materials was about 4%, the content of SiO2 was in the range of 8–10%, and R2O3 content was about 1%. It was also shown that the test material is not homogenous. Images from scanning electron microscope showed that in the waste occured irregularly agglomerates with a diameter between 30 and 100 microns. EDX analysis revealed that elements constituted NID wastes are oxygen, sulfur, calcium, chlorine, silicon, aluminum, copper and carbon.

  11. Profiler : Canadian oil and gas : the First Nations : building successful partnerships

    Anon.

    2010-05-15

    Canada's petroleum and natural gas is often produced in remote areas where the majority of the population is Aboriginal. Many First Nations and Metis communities are now playing an active role in Canada's oil and gas industry. Aboriginal-owned companies have earned more than $2.6 billion in the oil sands region since 1999. In 2007, the value of contracts between Alberta oil sands companies and Aboriginal companies was estimated at $606 million. This special supplement discussed First Nations partnerships in the oil and gas industry. Articles in the supplement presented new employment, training and partnership activities in the oil and gas industry as well as activities related to emerging unconventional resources. Educational programs and training facilities were described. The employment and procurement practices of leading oil and gas operators were discussed. The supplement featured presentations by several leading oil and gas companies. tabs., figs.

  12. Building America Case Study: Assessment of a Hybrid Retrofit Gas Water Heater

    M. Hoeschele, E. Weitzel, C. Backman

    2017-06-01

    This project completed a modeling evaluation of a hybrid gas water heater that combines a reduced capacity tankless unit with a downsized storage tank. This product would meet a significant market need by providing a higher efficiency gas water heater solution for retrofit applications while maintaining compatibility with the half-inch gas lines and standard B vents found in most homes. The TRNSYS simulation tool was used to model a base case 0.60 EF atmospheric gas storage water, a 0.82 EF non-condensing gas tankless water heater, an existing (high capacity) hybrid unit on the market, and an alternative hybrid unit with lower storage volume and reduced gas input requirements.

  13. Installation and investigation of a cogeneration system in a hospital building at Anieres; Installation et suivi d'un couplage chaleur-force (CCF) sur le site de l'ORT a Anieres

    NONE

    2004-07-01

    A system for combined heat and power generation has been added to the complex energy system of the ORT building of the general hospital at Anieres (canton Geneva, Southwestern Switzerland). Such a system allows both to reduce deficiencies of electric power and to supply the necessary sanitary hot water. The detailed investigation showed that the hydraulic inclusion of the cogeneration unit is of prime importance for obtaining a high number of operating hours, a prerequisite for economic operation. A hydraulic control of the primary loop by a temperature sensor in the return flow has proven to be adequate. Another critical point is the control of the cogeneration unit. The control must be very precisely adjusted if the requirements for electric power and warm water are to be fulfilled without heat dissipation. In this context, the management of the warm water storage tanks plays a decisive role.

  14. Safety requirements for buildings under induced earthquakes due to gas extraction

    Steenbergen, R.D.J.M.; Vrouwenvelder, A.C.W.M.

    2017-01-01

    In the Dutch province of Groningen over the last year shallow earthquakes are induced due to large scale gas extraction from the gas field at 3 km depth. The induced earthquakes differ from the better known tectonic earthquakes all over the world, caused by movement of the earth at large depths. The

  15. Using a gas-fired heat pump for heating and cooling in an office building

    Bergmann, E [Westfaelische Ferngas-A.G., Dortmund (Germany, F.R.)

    1979-01-01

    Within the frame of the efforts made for a rational energy application by using new technologies, especially the long-known concept of heat pumps was prepared for heat production in swimming pools, sport centers, and buildings. Motivated by these activities, this technology was used, with additional heat recovery, for air-conditioning an administration building. After investigating various supply systems, an energy concept was processed with the aim to optimize the relation of the building costs to the operational costs of the air-condition, ventilation,- and heating systems.

  16. Using of gas for water heating at buildings - study on technical and economical viability; Utilizacao de gas para aquecimento de agua em instalacoes prediais - estudo de viabilidade tecnica e economica

    Fossa, Alberto Jose [MDJ Assessoria e Engenharia Consultiva, Santo Amaro, SP (Brazil)]. E-mail: afossa@mdj.com.br; Chaguri, Jose Jorge [Caltherm Sistemas de Aquecimento, Sao Paulo, SP (Brazil)]. E-mail: jchaguri@caltherm.com.br; Santos, Edmilson Moutinho dos [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Eletrotecnica e Energia]. E-mail: edsantos@iee.usp.br

    2006-07-01

    The recent discovery of significant Brazilian's natural gas reserves has been opened a discussion concerning public procedures in order to incentive development of gas industry thru delivery of this energetic to the end consumer. Concerning this figure, a significant quantity of uses has been questioned related economical viability. This paper comes to analyze the possibility to change electrical energy for natural gas on heating water systems used on residential installations. Concerns about economical impact of alternative adopted on locals where public regulations are been established to incentive natural gas end uses. (author)

  17. Developing competition while building up the infrastructure of the Brazilian gas industry

    De Mello Sant Ana, Paulo Henrique; De Martino Jannuzzi, Gilberto; Valdir Bajay, Sergio

    2009-01-01

    For the last 20 years, countless countries have been carrying out structural reforms in the natural gas industry, trying to achieve efficiency and economic rationality with the introduction of competition. The objective of the paper is to present an approach to the development of competition and infrastructure of the Brazilian natural gas industry. This approach is based on a market projection to 2011, on the international experience and on the characteristics of the Brazilian market, infrastructure and regulatory framework. Possible impacts of the proposed measures are also provided. According to the market projection carried out in this paper, in 2011 there will be a possible surplus of natural gas in the country, which includes a dependence diminishing of the Bolivian gas supply. This gas surplus, allied to an upcoming Gas Law and the trade liberalization in the states of Sao Paulo and Rio de Janeiro, can stimulate the development of competition, if some changes that proposed in this paper are made in the current Gas Bills. The approach proposed herein seeks to stimulate non-discriminatory open access, focused on information transparency and tariff regulation to help the development of infrastructure and competition. (author)

  18. Update of the database of photovoltaic installations in the UK

    Taylor, D.; Bruhns, H.

    1999-07-01

    The article describes an updated database of photovoltaic (PV) installations in the UK. The database contains more than 300 records representing over 40,000 photovoltaic installations with more than 100 buildings that use photovoltaic arrays. Figures show: (i) a chart of cumulative PV applications to date; (ii) a chart of cumulative installations in the database; (iii) the growth of Building Integrated PV installed to date; (iv) the cumulative growth of peak power of PV for buildings installed every year since 1985; (v) the distribution by application of all PV installations in the database and (vi) the various applications of PV installations.

  19. Thermodynamic, ecological and economic aspects of the use of the gas turbine for heat supply to the stripping process in a supercritical CHP plant integrated with a carbon capture installation

    Bartela, Łukasz; Skorek-Osikowska, Anna; Kotowicz, Janusz

    2014-01-01

    Highlights: • Variants of integration of CHP plant with CCS and gas turbine unit were analyzed. • The simulations of operation of plants under changing load were realized. • Conditions of competitiveness for all solutions were identified. • Integration can be profitable if prices of allowance will reach values >60 €/MgCO 2 . - Abstract: This paper presents the results of thermodynamic and economic analyses for eight variants of a combined heat and power (CHP) plant fuelled with coal working under supercritical steam parameters and integrated with a CO 2 capture installation and a gas turbine system. The motivation behind using a gas turbine in the system was to generate steam to supply heat for the stripping process that occurs in the separation installation to regenerate the sorbent. Additional analyses were conducted for the reference case, a CHP unit in which the CO 2 separation process was not conducted, to enable an economic evaluation of the integration of a CHP unit with a CO 2 separation installation according to the variants proposed. The break-even price of electricity and avoided emission costs were used to evaluate the respective solutions. In this paper, the results of the sensitivity analysis of the economic evaluation indicators in terms of the change in the annual operation time, price of emission allowance and heat demand rate for the realization of the stripping process for all cases are presented

  20. Design/installation and structural integrity assessment under the Federal Facility Agreement for Bethel Valley Low-Level Waste Collection and Transfer System upgrade for Building 2026 (High Radiation Level Analytical Laboratory) and Building 2099 (Monitoring and Control Station) at Oak Ridge National Laboratory

    1994-10-01

    This document presents a Design/Installation and Structural Integrity Assessment for a replacement tank system for portions of the Bethel Valley Low Level Waste (LLW) System, located at the Oak Ridge Reservation, Oak Ridge, Tennessee. This issue of the assessment covers the design aspects of the replacement tank system, and certifies that the design has sufficient structural integrity and is acceptable for the storing or treating of hazardous and/or radioactive substances. The present issue identifies specific activities that must be completed during the fabrication, installation, and testing of the replacement tank system in order to provide assurance that the final installation complies with governing requirements. Portions of the LLW system are several decades old, or older, and do not comply with current environmental protection regulations. Several subsystems of the LLW system have been designated to receive a state-of-the-art replacement and refurbishment. One such subsystem serves Building 2026, the High Radiation Level Analytical Laboratory. This assessment focuses on the scope of work for the Building 2026 replacement LLW Collection and Transfer System, including the provision of a new Monitoring and Control Station (Building 2099) to receive, store, and treat (adjust pH) low level radioactive waste

  1. Comparison of revegetation of a gas pipeline right-of-way in two forested wetland crossings involving conventional methods of pipeline installation and horizontal drilling, Nassau County, Florida

    Van Dyke, G.D. [Trinity Christian Coll., Palos Heights, IL (United States). Dept. of Biology; Shem, L.M.; Zimmerman, R.E. [Argonne National Lab., IL (United States)

    1993-10-01

    One year after pipeline installation, vegetation in the right-of-way (ROW) was inventoried at two stream floodplain crossings in Nassau County, Florida. Both sites were forested wetlands composed of Acer rubrum, Fraxinus caroliniana, Liquidamber styraciflua, Nyssa ogecho, Quercus laurifolia, and Taxodium distichum, together with other wetland trees. Pipeline installation across the Brandy Branch floodplain was by conventional ditching and backfill methods. Installation across the Deep Creek floodplain was by horizontal drilling after clearcutting the ROW. The latter method left tree stumps, understory vegetation, and soil layers intact, except for disruptions caused by logging. According to the inventory, vegetation at the drilled site was more diverse (nearly twice as many species occurring in the ROW as at the trenched site) and more robust (no unvegetated exposed soil compared to 15% at the trenched site). Differences between the ROW vegetation at the two sites can be attributed to both site differences and installation technologies used.

  2. Border installations

    Lenaerts, K.

    1988-01-01

    This chapter highlights the legal problems raised by the concept of a border installation. Using the Cattenom nuclear power plant as an example, the author describes the different stages of the legal conflict raised by construction of the plant and analyses the relationship between French administrative law and some provisions of the Euratom Treaty. Based on the Treaty, the Community institutions have adopted directives to strengthen inter-State co-operation and consultation between neighbouring countries. He observes that these principles of co-operation, consultation and vigilance already exist in public international law; however, international case law has not yet made it possible to establish the strict liability of the constructing state in case of a nuclear accident (NEA) [fr

  3. Building the NGV [natural gas vehicle] industry into the 21st century

    Eaves, M.

    1992-01-01

    The status and potential of the natural gas vehicle (NGV) industry is reviewed. The current status of NGV technology is discussed, and a perspective on the business potential of NGV is offered. The cost of compressed natural gas is compared with the cost of conventional fuel options. At present there is a ca 92-97 cent/gallon differential between natural gas and gasoline, however it is not clear that this is sufficient to provide an incentive for purchasing a compressor. The economics of running a Sierra pickup truck are calculated, and it is proposed that a fuel cost differential in the order of 30 cents may be enough to entice consumers to purchase NGV. The gas industry is expected to finance the fuelling infrastructure for NGVs for the reasonable future. The investment must be made using a 25-40 cent per therm differential (or 30-50 cent/gallon equivalent) to finance compressor facilities. Extensive tables and graphs are presented that show the dependence of number of vehicles (and gas sales) on simple payback periods for compressor facilities. 4 figs., 19 tabs

  4. Formulation of models for determination of the fuel gas demand and consumption in residential buildings; Formulacao de modelos para determinacao da demanda e consumo de gas combustivel em edificios residenciais

    Ilha, Marina Sangoi de Oliveira [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Civil. Dept. de Hidraulica e Saneamento; Goncalves, Orestes Marracini [Sao Paulo Univ., SP (Brazil). Escola Politecnica. Dept. de Engenharia de Construcao Civil

    1996-07-01

    This work presents models for design flow rate and gas volume determination in residential buildings. First, an experimental investigation, applied on a sample of residential buildings at Sao Paulo, Brazil, is described, which essentially consisted in the filling of a form and measurement of gas volume at one minute interval during 10 days (mean). From this data, it was performed a regression analysis in order to explain design flow rate (demand) and gas volume values (consumption), based on different variables. Models proposed on this work are different from the current applied methodology due to their 'open' approach, that is, involved variables can be explicitly found in formulas. (author)

  5. Expert methods in control systems of deep oil and gas holes building

    Sementsov, G.; Fadeeva, I.; Chigur, I. [State Technical Univ. of Oil and Gas, Ivano-Frankivsk (Ukraine)

    2000-07-01

    Attempts to provide self-control of process of long holing on oil and gas have not given due effect owing to complication of object, it fuzzy and equivocation of the information. In this connection it is offered to use for management of drilling expert systems, which one use fuzzy models and methods of the theory of fuzzy control systems. (orig.)

  6. Solar-energy landmark Building-Columbia, Missouri

    1981-01-01

    Report includes design, cost, installation, maintenance, and performance details for attractive solar installation which supplies space heating for four-story Visitors Center. 176 hydronic flat-plate collectors, water-to-water heat exchanger, and 5,000-gallon storage tank comprise system which provides 71 percent of building's heat. Natural-gas-fired boiler supplies auxiliary hot water to heating system when necessary.

  7. An anus of operation of a refrigeration system and installed solar heating in the CIESOL Building: Arfrisol project; Un ano de operacion de un sistema de refrigeracion y calefaccion solar instalado en el Edificio Ciesol: Proyecto Arfrisol

    Rosiek, S.; Batlles, F. J.

    2008-07-01

    In this paper we will analyse the thermodynamic behaviour of the solar-assisted air-conditioning system installed in the CIESOL building, operating in both heating and cooling mode. This system consists mainly of flat-plate solar collectors and the simple effect LiBr-H{sub 2}O absorption chiller and has been operating since October 2006. We will analyze the behaviour of the flat-plate collectors array during whole year of operation. The average values of coefficient of performance and the cooling capacity were calculated for summer months, obtaining values of order of 60% and 40 kW respectively. Finally, the energy and CO{sub 2} saving were estimated, obtaining values of order of 17000 kWh/year and 13 tons/year respectively. (Author)

  8. Response of a reactor building due to detonation of flat layered gas clouds

    Frik, G.

    1984-05-01

    The stress of the containment of a PWR plant of today is calculated for the loading of three detonating flat layered gas clouds. The dynamic response of the structure due to the blast wave is determined and comparisons are made with previous results of the detonating stochiometric gas cloud and with results of the individual task 11A (GRS). The calculations were realized with the method of modal superposition and linear elastic material laws. The stress conditions of the structure were comprehended by three loading cases of the flat, layered gas clouds. The first loading case B(a) leads to high stresses, which are not interpretable with a linear analysis. On the other hand, the loading case B(b) leads to stresses which are not much above and B(c) to stresses which are not much below the yield stress. It is demonstrated for a linear analysis, that the structure will not be injured by the detonation wave of case B(c). (orig./HP) [de

  9. Strong explosions impact on buildings representative of an industrial facility; Impact de fortes explosions sur les batiments representatifs d'une installation industrielle

    Trelat, S

    2006-12-15

    The goal of this study is to focus on the analysis of blast wave damage to structures when blast wave is consequence of explosive charge detonation. The objective is to propose useful tools to predict charges on structure. All experiences are realized in laboratory. The experimental investigation consists in simulating a detonation of a stoichiometric propane-oxygen mixture at ground level or at higher altitude. The study is going to give us experimental data on blast wave effects on a structure. For that, two types of structures frequently found on industrial site are going to be used: a parallelepipedal structure and a cylindrical structure, both with known dimensions. Finally, the important point of the problem is to determine an energetic equivalence between TNT and gas used in the experiments, in order to model TNT explosions at full scale by gaseous explosions at reduced scale. (author)

  10. Preliminary experimental investigation of a natural gas-fired ORC-based micro-CHP system for residential buildings

    Farrokhi, M.; Noie, S.H.; Akbarzadeh, A.A.

    2014-01-01

    The continual increases in energy demand and greenhouse gas emissions, call for efficient use of energy resources. Decentralized combined heat and power (CHP) technology provides an alternative for the world to meet and solve energy-related problems including energy shortages, energy supply security, emission control and conservation of energy. This paper presents the preliminary results of an experimental investigation of a natural gas-fired micro-CHP system for residential buildings based on an organic Rankine cycle (ORC). Isopentane was used as the ORC working fluid in consideration of several criteria including its environmentally-friendly characteristics. Experiments were conducted to evaluate the performance of the developed system at different heat source temperatures of nominally 85, 80, 75, 70, and 65 °C. The maximum electrical power output of 77.4 W was generated at heating water entry temperature of 84.1 °C, corresponding to net cycle electrical efficiency of 1.66%. Further work will be done with a view to increasing the cycle electrical efficiency by using more efficient components, in particular the expander and generator. - Highlights: •A natural gas-fired ORC-based micro-scale CHP system has been developed and tested. •The good agreement between the mechanical and gross power validates the assumptions. •A vane expander suits a micro-CHP system based on an organic Rankine cycle. •A vane expander does not suit power generation by a Trilateral Flash Cycle (TFC). •Domestic gas-fired ORC systems may reduce reliance on central power stations

  11. Installation package - home solar heater

    1980-01-01

    Installation of commerical solar-heating system at two story, three bedroom house in New Hampshire is described in 65 page report. System collectors are integrated part of building replacing conventional roofing or siding. Report also includes general description of system, its operation and guidelines, orientation and references.

  12. Nanoparticles from the Gas Phase as Building Blocks for Electrical Devices

    Fissan, H.; Kennedy, M.K.; Krinke, T.J.; Kruis, F.E.

    2003-01-01

    Electrical device development is driven by miniaturization and possibilities to use new chemical and physical effects. Nanotechnology offers both aspects. The structural dimensions of materials and devices are small and because of that large exchange surfaces are provided but also effects like quantum effects may occur and be used to get new or at least improved properties of nanostructured materials and devices.Nanoparticles are of special interest because of their nanodimensions in all three directions, so that nanoeffects become most prominent. They can be synthesized in solid materials, in liquids and in gases. Gas synthesis has several advantages compared to the other phases, especially the high cleanliness which can be achieved. In case of electrical devices the particles have to be deposited onto substrates in a structured way.The substrate may consist out of microelectronic devices in which the deposited nanoparticles are introduced for the basic function. In case of a transistor this would be the gate function, in case of a sensor this would be the sensing layer, where the contact with the measurement object takes place. For two kinds of particles SnO 2 and PbS, synthesized in the gas phase, we demonstrate the way how to create devices with improved sensor properties

  13. To fully exert the important role of natural gas in building a modern energy security system in China: An understanding of China's National l3th Five-Year Plan for Natural Gas Development

    Zhen Wang

    2017-07-01

    Full Text Available Along with the introduction of 13th Five-Year Plans in succession for natural gas development programmed by governments at all levels and much more attention paid to haze governance by relevant departments, natural gas, as one of the major energy sources, has ushered in a strategic opportunity era. In view of this, based upon China's National 13th Five-Year Plan for Natural Gas Development formulated by the National Development and Reform Commission, the developing trend of natural gas sector was predicted in the period of 13th Five-Year Plan in terms of supply side, demand side, pricing system, infrastructure construction, etc. and some feasible proposals were made on the whole industrial chain. In terms of the supply side, natural gas will be of availability, accessibility, assurance, affordability, and accountability in the production and supply chains. In terms of the demand side, air pollution treatment will indirectly stimulate gas consumption increase. Gas power generation will become the dominant. Natural gas as a transportation fuel will bring a good new opportunity. Thus it is believed that as the present natural gas development is restricted by both gas pricing system and infrastructure construction, further reform should be strengthened to break the barriers of systems and mechanisms; and that due to many uncertainties in the natural gas market, the decisive role of market in the resource allocation should be fully exerted to ensure the main force of natural gas in building a dependable energy strategic system in present and future China.

  14. Solar Water Heater Installation Package

    1982-01-01

    A 48-page report describes water-heating system, installation (covering collector orientation, mounting, plumbing and wiring), operating instructions and maintenance procedures. Commercial solar-powered water heater system consists of a solar collector, solar-heated-water tank, electrically heated water tank and controls. Analysis of possible hazards from pressure, electricity, toxicity, flammability, gas, hot water and steam are also included.

  15. Building and interconnecting hydrogen networks: Insights from the electricity and gas experience in Europe

    Bento, Nuno

    2008-01-01

    This paper aims to investigate the transition to a new energy system based on hydrogen in the European liberalized framework. After analyzing the literature on the hydrogen infrastructure needs in Europe, we estimate the size and scope of the transition challenge. We take the theoretical framework of network economics to analyze early hydrogen infrastructure needs. Therefore, several concepts are applied to hydrogen economics such as demand club effects, scale economies on large infrastructures, scope economies, and positive socio-economical externalities. Based on the examples of the electricity and natural gas industry formation in Europe, we argue for public intervention in order to create conditions to reach more rapidly the critical size of the network and to prompt network externalities, allowing for the market diffusion of and, thus, an effective transition to the new energy system

  16. A Real-Time Construction Safety Monitoring System for Hazardous Gas Integrating Wireless Sensor Network and Building Information Modeling Technologies.

    Cheung, Weng-Fong; Lin, Tzu-Hsuan; Lin, Yu-Cheng

    2018-02-02

    In recent years, many studies have focused on the application of advanced technology as a way to improve management of construction safety management. A Wireless Sensor Network (WSN), one of the key technologies in Internet of Things (IoT) development, enables objects and devices to sense and communicate environmental conditions; Building Information Modeling (BIM), a revolutionary technology in construction, integrates database and geometry into a digital model which provides a visualized way in all construction lifecycle management. This paper integrates BIM and WSN into a unique system which enables the construction site to visually monitor the safety status via a spatial, colored interface and remove any hazardous gas automatically. Many wireless sensor nodes were placed on an underground construction site and to collect hazardous gas level and environmental condition (temperature and humidity) data, and in any region where an abnormal status is detected, the BIM model will alert the region and an alarm and ventilator on site will start automatically for warning and removing the hazard. The proposed system can greatly enhance the efficiency in construction safety management and provide an important reference information in rescue tasks. Finally, a case study demonstrates the applicability of the proposed system and the practical benefits, limitations, conclusions, and suggestions are summarized for further applications.

  17. Rules and regulations on ionizing radiations sources installations

    1980-01-01

    The finality of this legislative text is to establish the standards and procedures for site, design, building, operation and decommissioning of nuclear installations, radioactive installations and ionizing radiations sources. This text include the commercialization of radioactive substances and equipment fabrication

  18. Installation of a radioactive waste disposal facility. The necessity of building up durable links between the general public and radioactive waste. Feedback from experience in France

    Comte, Annabelle; Farin, Sebastien

    2015-01-01

    2013 has been a banner year for Andra with widespread discussions on the question of long-term management of radioactive waste: a nationwide public discussion about the planned Cigeo deep disposal facility has been organized and national discussions on the energy source transition had inevitably brought up the question of what to do with future radioactive waste to be produced under the various scenarios put forward. In spite of an open institutional framework, with numerous legal provisions for citizen participation, 2013 showed that creation of a radioactive waste disposal facility is not, and cannot be, a question dealt with like breaking news, within a given temporal or spatial perimeter. Any attempts to bring up the subject under the spotlight of public scrutiny inevitably shift the discussions away from their central theme and abandon the underlying question - what should be done with the existing radioactive waste and the waste that is bound to be produced? - to move on to the other major question: ''Should we stop using nuclear power or not?'', which takes us away from our responsibilities towards future generations. Daring to face the question, anchor it in citizen discussions, and create awareness of our duties towards coming generations: this is the challenge that Andra had already set itself several years ago. Our position is a strong one; rather than seeking to mask the problem of radioactive waste, we must face up to our responsibilities: the waste is already there, and we have to do something with it. It will take time to be successful here. Long-term management of radioactive waste is clearly a really long-term matter. All the experience in the field has shown that it involves patience and careful listening, and requires building up a basis for solid trust among the potential neighboring population, who are the most directly concerned. Durable proximity human investment is one of the key factors of success. For over 20 years now

  19. Installation of a radioactive waste disposal facility. The necessity of building up durable links between the general public and radioactive waste. Feedback from experience in France

    Comte, Annabelle; Farin, Sebastien [Andra, Chatenay-Malabry (France)

    2015-07-01

    2013 has been a banner year for Andra with widespread discussions on the question of long-term management of radioactive waste: a nationwide public discussion about the planned Cigeo deep disposal facility has been organized and national discussions on the energy source transition had inevitably brought up the question of what to do with future radioactive waste to be produced under the various scenarios put forward. In spite of an open institutional framework, with numerous legal provisions for citizen participation, 2013 showed that creation of a radioactive waste disposal facility is not, and cannot be, a question dealt with like breaking news, within a given temporal or spatial perimeter. Any attempts to bring up the subject under the spotlight of public scrutiny inevitably shift the discussions away from their central theme and abandon the underlying question - what should be done with the existing radioactive waste and the waste that is bound to be produced? - to move on to the other major question: ''Should we stop using nuclear power or not?'', which takes us away from our responsibilities towards future generations. Daring to face the question, anchor it in citizen discussions, and create awareness of our duties towards coming generations: this is the challenge that Andra had already set itself several years ago. Our position is a strong one; rather than seeking to mask the problem of radioactive waste, we must face up to our responsibilities: the waste is already there, and we have to do something with it. It will take time to be successful here. Long-term management of radioactive waste is clearly a really long-term matter. All the experience in the field has shown that it involves patience and careful listening, and requires building up a basis for solid trust among the potential neighboring population, who are the most directly concerned. Durable proximity human investment is one of the key factors of success. For over 20 years now

  20. Lightning protection system analysis at Multipurpose Reactor G A. Siwabessy building

    Teguh-Sulistyo

    2003-01-01

    Analysis to the part of lightning protection system at Multi Purpose Reactor GA Siwabessy (RSG-GAS) have been done. Observation examined the damage of some part of the earthing system caused by human error of chemically system. The analysis performed some assumptions and simulations to the points of lightning stroke. From this analysis obtained that the reactor building do not have vertical finial which can protect effectively to the whole reactor building and auxiliary building. Installing some new finials at some places are needed to protect building therefore the reactor building and auxiliary building well safe from lighting stroke

  1. Calculating green house gas emissions for buildings: analysis of the performance of several carbon counting tools in different climates

    La Roche, P.

    2010-03-01

    Full Text Available The first step to reduce greenhouse gas emissions from buildings is to be able to count them. If this counting is integrated in the design process the impact of architectural design strategies can be evaluated more easily and a building with reduced emissions can be developed. Fifty greenhouse gas calculators and energy modeling software were compared in the main areas in which buildings are responsible for carbon emissions: operation, water, construction, waste and transportation to and from the building. These tools had to be free and easy to use so that they could be used by everybody in the initial phases of the architectural design process, while providing sufficient precision to provide useful input to the designer. The effect of modifying the envelope insulation, the quality of the windows, the efficiency of the heating and cooling systems, and integrating direct gain and night ventilation, on operation emissions was evaluated with two energy modeling tools: HEED and Design Builder. Results demonstrated that implementing appropriate design strategies significantly reduced emissions from operation in all climates. An easy to implement protocol that combines several tools for GHG counting in buildings is provided at the end.

    El primer paso para reducir las emisiones de gases invernadero generadas por las edificaciones es el poder calcularlas adecuadamente. Si esta actividad se integra al proceso de diseño arquitectónico; entonces el impacto de las estrategias de diseño se puede evaluar más fácilmente; resultando un edificio con menores emisiones. Cincuenta herramientas de cálculo de emisiones y programas de modelaje se compararon en las áreas en las cuales los edificios son responsables de las emisiones de gases invernadero: operación; agua; construcción; basura; y transporte desde y hasta el edificio. Las herramientas comparadas debían ser fáciles de utilizar; pero con suficiente precisión para proveer información de

  2. Installed water resource modelling systems for catchment ...

    Following international trends there are a growing number of modelling systems being installed for integrated water resource management, in Southern Africa. Such systems are likely to be installed for operational use in ongoing learning, research, strategic planning and consensus-building amongst stakeholders in the ...

  3. Integrated Life Cycle Energy and Greenhouse Gas Analysis of Exterior Wall Systems for Residential Buildings

    Reza Broun

    2014-11-01

    Full Text Available This paper investigates the breakdown of primary energy use and greenhouse gas (GHG emissions of two common types of exterior walls in the U.K.: insulated concrete form (ICF and cavity walls. A comprehensive assessment was conducted to evaluate the environmental performance of each exterior wall system over 50 years of service life in Edinburgh and Bristol. The results indicate that for both wall systems, use phase is the major contributor to the overall environmental impacts, mainly due to associated electricity consumption. For the ICF wall system in Edinburgh, 91% of GHG emissions were attributed to the use phase, with 7.8% in the pre-use and 1.2% in end-of-life phases. For the same system in Bristol, emissions were 89%, 9% and 2%, respectively. A similar trend was observed for cavity wall systems in both locations. It was concluded that in each scenario, the ICF wall system performed better when compared to the cavity wall system. The results of the sensitivity analysis clearly show that the uncertainties relevant to the change of the thickness of the wall are quite tolerable: variable up to 5%, as far as energy and greenhouse emissions are concerned.

  4. Solar Panel Installations on Existing Structures

    Tim D. Sass; Pe; Leed

    2013-01-01

    The rising price of fossil fuels, government incentives and growing public aware-ness for the need to implement sustainable energy supplies has resulted in a large in-crease in solar panel installations across the country. For many sites the most eco-nomical solar panel installation uses existing, southerly facing rooftops. Adding solar panels to an existing roof typically means increased loads that must be borne by the building-s structural elements. The structural desig...

  5. Selection tests of rubber coatings for the purpose of washing towers and other components in flue gas desulfurization installations. Selectietesten van rubberdeklagen ten behoeve van wastorens en andere componenten in rookgasontzwavelingsinstallaties; Deel 1

    Schipper, B.A.; Van Manen, J. (KEMA Inspecties en Materialen, Arnhem (Netherlands))

    1993-01-01

    It has appeared that the service life of chloroprene-based rubber coatings in flue gas desulfurization (FGD) installations in coal-fired power plants in the Netherlands is short. A number of rubber coating types, applied in washing towers, pipelines, pumps and boilers of FGD installations, is tested on a laboratory scale. Use has been made of the KEMA-developed accelerated test method, the Delta-T-Tube Test. In this test a rubber foil is attached to the outside of a tube. The tube is internally cooled and the outside is exposed to a test medium. Also use has been made of the KEMA-FGD test facility to expose the pipes in the washing tank and in the flue gas canal. Plates, coated with a rubber foil, are tested in so-called Atlas cells. The tubes and the plates were controlled for blister and crack formation and for erosion. Thermal analyses methods and mechanical tests were carried out to characterize the plates and the tubes before and after the exposures. It is concluded that butyl-based rubbers show better results than chloroprene-based rubbers

  6. Market entry mode and competency building of Western oil companies in the Russian up stream oil and gas industry

    Stephenson, Paul M.

    This dissertation investigated the market entry and competency building strategies within the context of the Russian oil and gas industry. The study was designed to be of interest to business practitioners and academics given the growing importance of fossil fuel in the energy balance of the global economy and the importance of Russia as a supplier and purchaser in the international market. The study's mixed methodology provides an understanding on the environmental factors that are postulated to impact foreign direct investment flow into Russia and the oil and gas sector. A case study of a fictitiously named Western-Russo oil company was conducted to provide a deep understanding of how capability is viewed by Russian and Western employees and the factors that influences the implementation of a successful competency development program. The case was centered on the development of a Well-Site supervisor group within a Western-Russian oil company. Findings of the study showed that there was no correlation between corruption and foreign direct investment inflow into the Russian economy. The findings also showed that both Russian and Western employees in the oil and gas industry are less focused on nontechnical competency development issues, that Western employees are more orientated towards the bottom-line than Russian employees, and that both groups see operational management as a core competency. In the area of financial management and technology application, there were significant differences in the viewpoint of both groups. Western employees saw a stronger need for financial management and less need for technology application when compared to their Russian counterparts. The results have implications for Western business contemplating entering the Russian oil and gas industry. Western firms need to understand the key drivers that will help them overcome the social and cultural barriers between Western and Russian employees. The role of the company leader is very

  7. Historical Consumption of Heating Natural Gas and Thermal Monitoring of a Multifamily High-Rise Building in a Temperate/Cold Climate in Argentina

    Celina Filippín

    2012-12-01

    Full Text Available This paper analyzes the historical consumption of natural gas in a multifamily high-rise building and the monitored winter thermal behavior of an apartment sample. The building is located in the center of Argentina (latitude: 36º27’S; longitude: 64º27’W, where the climate is a cold temperate with an absolute minimum temperature that may reach −10 °C. The building has two blocks, North and South. The building’s annual gas consumption and its variability between 1996 and 2008 are shown. The South block consumed 78% more gas, a situation expected due to lower solar resource availability and greater vulnerability regarding strong and cold SW winds. Indoor temperatures monitored during 2009 in four apartments are described. The outdoor minimum temperature reached −5 °C, with solar irradiance around 500 W/m2 at midday. Results showed that the average indoor temperatures were 20.1, 20.6, 24.0 and 22.1 °C. The highest consumption value corresponded to the apartment exposed to SW cold winds. Compared to the rest of the building, the apartment on the top floor consumes 59% more energy than the average for the gas consumed throughout the year. The authors assume that the energy potentials of intervention are different, and not necessarily all the apartments should have the same technological response.

  8. Gas

    1996-01-01

    The French government has decided to modify the conditions of extension of local natural gas authorities to neighbouring districts. The European Union is studying the conditions of internal gas market with the objective of more open markets although considering public service requirements

  9. A prototype of one of the eight sections that will form one of the big-wheels of the ATLAS muon spectrometer has been installed in building 887 at Prévessin . Over 40 institutes in 11 countries are involved in the construction of the ATLAS muon spectrometer.

    Patrice Loïez

    2001-01-01

    A prototype of one of the eight sections that will form one of the big-wheels of the ATLAS muon spectrometer has been installed in building 887 at Prévessin . Over 40 institutes in 11 countries are involved in the construction of the ATLAS muon spectrometer.

  10. Recommendations for main line block valves installation in gas pipelines; Recomendacoes para instalacao de valvulas de bloqueio de linha tronco em gasodutos

    Frisoli, Caetano [TRANSPETRO - PETROBRAS Transportes, Rio de Janeiro, RJ (Brazil); Oliveira, Valeriano Duque de [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Cases of gas pipelines block valves and its pneumatic actuators presenting problems during the final pipeline commissioning and pre-operation phases, like internal leaks, leaking to the atmosphere, pneumatic circuit defects caused by water and debris, are nearly common. The majority can be avoided if a series of measuring are to be planned and implemented, as well as if an adequate planning of commissioning operations and line gasification, valves and actuators, are to be applied. This paper shows the practical experience in the construction and commissioning of valves and its actuators in the Bolivia-Brazil gas pipeline, which, in the first construction phase had a series of problems. After the diagnosis a set of procedures was implemented in the secondary construction phase, resulting in insignificant problems detected. All measures and procedures taken in the planning process, as well as additional aspects related to the main line valve design, its by-passes and supports, are demonstrated. (author)

  11. Artificial intelligence in gas plant operation help; L'intelligence artificielle dans l'aide a l'exploitation des installations gazieres

    Pietrzak, J.M. [Gaz de France (GDF), Centre d' Expertise Operationnelle et de Service, Dir. de la Production et du Transport, 75 - Paris (France)

    2000-07-01

    The problems encountered in activities associated with the life cycle of gas plants - in the core business sectors of GDF- demonstrate the need to access this know how in a practical and efficient way for an optimise use and operation of these gas plants. Simulation is an excellent tool for integration and transfer of this know-how. It requires to use methods and technologies of Artificial Intelligence and objects in particular. The operation help tools and prototypes have been developed with the co-operation and investment of a little software company and derive from the commitment and desire of a number of experts and their senior managers to prepare the future and invest in the durability of know-how in the company's core business sectors. (author)

  12. NEMP effects on domestic installation

    Braun, C.; Clemens, P.; Graf, W.; Guidi, P.; Schmidt, H.U.

    1985-01-01

    The measurements have been made in a building of a psychiatric clinic at Alzey/West Germany. The building has been chosen for the measuring campaign because it has its own electrical installation for mains current supply and emergency power supply, apart from systems of the other buildings. The two supply systems DONNERSBERG could be cut off completely from the other mains systems, so that coupling and feed experiments could be made without mains voltage. Current supply to the measuring systems was done by means of extension cables, or by batteries. The wiring for connection to the room circuits is parallel to the exterior wall, so that measurements could be done by using a frame antenna placed outside of the building parallel to the exterior wall. (orig./DG) [de

  13. Liquefied natural gas storage at Ambergate

    Higton, C W; Mills, M J

    1970-08-19

    Ambergate works was planned in 1965-1966 and the decision was taken to install 4 ICI lean gas reformers using natural gas as feedstock, fuel, and enrichment. To cover the possible failure of natural gas supplies, petroleum distillate would be used as alternative feedstock and fuel. The choice for alternative enrichment lay between LPG or LNG. Since LNG would provide peak-on-peak storage facilities for either the East Midlands Board or the Gas Council when conversion was completed--and in the meantime would provide an additional source of LNG for local requirements when temporary LNG installations were used during conversion--agreement was reached with the Gas Council for it to build a 5,000-ton storage installation at Ambergate. The installation consists of 3 major sections: (1) the offloading bay and storage tank; (2) the reliquefaction system; and (3) the export system. The offloading bay and storage tank are for the reception and storage of liquefied Algerian natural gas, delivered to Ambergate by road tanker from the Canvey Is. Terminal. The reliquefaction system is to maintain the necessary storage tank conditions by reliquefying the boil-off natural gas. The export system delivers LNG from the storage tank at high pressure through a vaporization section in the national methane grid.

  14. Large eddy simulation of pollutant gas dispersion with buoyancy ejected from building into an urban street canyon.

    Hu, L H; Xu, Y; Zhu, W; Wu, L; Tang, F; Lu, K H

    2011-09-15

    The dispersion of buoyancy driven smoke soot and carbon monoxide (CO) gas, which was ejected out from side building into an urban street canyon with aspect ratio of 1 was investigated by large eddy simulation (LES) under a perpendicular wind flow. Strong buoyancy effect, which has not been revealed before, on such pollution dispersion in the street canyon was studied. The buoyancy release rate was 5 MW. The wind speed concerned ranged from 1 to 7.5m/s. The characteristics of flow pattern, distribution of smoke soot and temperature, CO concentration were revealed by the LES simulation. Dimensionless Froude number (Fr) was firstly introduced here to characterize the pollutant dispersion with buoyancy effect counteracting the wind. It was found that the flow pattern can be well categorized into three regimes. A regular characteristic large vortex was shown for the CO concentration contour when the wind velocity was higher than the critical re-entrainment value. A new formula was theoretically developed to show quantitatively that the critical re-entrainment wind velocities, u(c), for buoyancy source at different floors, were proportional to -1/3 power of the characteristic height. LES simulation results agreed well with theoretical analysis. The critical Froude number was found to be constant of 0.7. Copyright © 2010 Elsevier B.V. All rights reserved.

  15. Design and installation of earth energy systems

    Loggia, S; Adragna, M; Coyle, S; Foley, C; Hawryn, S; Martin, A; McConnell, J [eds.

    2002-07-01

    This first edition of the Canadian Standards Association (CSA) Standard C448 Series, replaces CSA Standards CAN/CSA-C445-M92 entitled Design and Installation of Earth Energy Heat Pump Systems for Residential and Other Small Buildings, as well as C447-94 entitled Design and Installation of Earth Energy Heat Pump Systems for Commercial and Institutional Buildings. This standard document consists of three parts: (C448.1) Design and installation of earth energy systems for commercial and institutional buildings; (C448.2) Design and installation of earth energy systems for residential and small buildings; and, (C448.3) Design and installation of underground thermal energy storage systems for commercial and institutional buildings. In C448.1, the requirements applicable to any system falling within the scope of the C448 series were included. Alternative requirements for houses and small buildings were added in C448.2. It was noted that either standard may be implemented. The standards applicable to the intentional storage of energy in the earth for later use were presented in C448.3. This latter section includes a brief introduction on underground thermal energy storage (UTES). tabs.

  16. The radon gas at the context of legislation on the quality of internal air in buildings - the Portuguese experience; O gas radao no contexto da legislacao sobre a qualidade do ar interior em edificios - a experiencia portuguesa

    Pinto, Paulo G.A.N.; Pereira, Alcides J.S.C.; Neves, Luis J.P.F., E-mail: ppinto@dct.uc.p, E-mail: apereira@dct.uc.p, E-mail: luisneves@dct.uc.p [Universidade de Coimbra (Portugal). Dept. de Ciencias da Terra. Instituto do Mar

    2011-10-26

    Radon gas has been recognized as an important environmental risk factor, especially when found in high concentrations inside buildings, and is currently classified by the World Health Organization as a carcinogen type 1. In this context, there is legislation in Portugal since 2006 that sets limits to its concentration in indoor air. The aim of this work was to synthesize the existing legislation with focus on the sampling and analysis. Some statistical data about the measurements obtained in the Natural Radioactivity Laboratory, of the Department of Earth Sciences, of the University of Coimbra are presented, and discussed in the context of the National Energy Certification of Buildings System

  17. Structural considerations for solar installers : an approach for small, simplified solar installations or retrofits.

    Richards, Elizabeth H.; Schindel, Kay (City of Madison, WI); Bosiljevac, Tom; Dwyer, Stephen F.; Lindau, William (Lindau Companies, Inc., Hudson, WI); Harper, Alan (City of Madison, WI)

    2011-12-01

    Structural Considerations for Solar Installers provides a comprehensive outline of structural considerations associated with simplified solar installations and recommends a set of best practices installers can follow when assessing such considerations. Information in the manual comes from engineering and solar experts as well as case studies. The objectives of the manual are to ensure safety and structural durability for rooftop solar installations and to potentially accelerate the permitting process by identifying and remedying structural issues prior to installation. The purpose of this document is to provide tools and guidelines for installers to help ensure that residential photovoltaic (PV) power systems are properly specified and installed with respect to the continuing structural integrity of the building.

  18. Bridging interpersonal installation art with tangible business modeling

    Mitchell, Robb

    2012-01-01

    This position paper introduces an exploration of what deploying physical artefacts to enliven discussions about business innovation has in common with building room sized mechanical installations to provoke social interaction.......This position paper introduces an exploration of what deploying physical artefacts to enliven discussions about business innovation has in common with building room sized mechanical installations to provoke social interaction....

  19. Feasibility analysis of installing a natural gas cogeneration system in a slaughterhouse; Analise da viabilidade da implantacao de um sistema de cogeracao de energia a gas natural em um frigorifico

    Takaki, Alessandro Tomio; Dib, Fernando Henrique; Campitelli, Flavio Moreti; Romao Junior, Ricardo Agudo; Ramos, Ricardo Alan Verdu [Universidade Estadual Paulista (NUPLEN/UNESP), Ilha Solteira, SP (Brazil). Dept. de Engenharia Mecanica. Nucleo de Planejamento Energetico, Geracao e Cogeracao de Energia], Email: nuplen@dem.feis.unesp.br

    2006-07-01

    In this work the analysis of the viability of implantation of a natural gas cogeneration system in a bovine slaughterhouse is carried out. Among the studied configurations there are the current plant and the modified plant that allow the use of natural gas. For evaluation of the performance, energetic and exegetic analyses for each one of the configurations are carried out. It's also accomplished a thermo economic analysis that makes possible to evaluate the reflexes of the investment and combustible on the composition of the cost of products. (author)

  20. Nuclear Installations Act 1965

    1965-01-01

    This Act governs all activities related to nuclear installations in the United Kingdom. It provides for the licensing procedure for nuclear installations, the duties of licensees, the competent authorities and carriers of nuclear material in respect of nuclear occurrences, as well as for the system of third party liability and compensation for nuclear damage. The Act repeals the Nuclear Installations (Licensing and Insurance) Act 1959 and the Nuclear Installations (Amendment Act) 1965 except for its Section 17(2). (NEA) [fr

  1. Installation report - Lidar

    Georgieva Yankova, Ginka; Villanueva, Héctor

    The report describes the installation, configuration and data transfer for the ground-based lidar. The unit is provided by a customer but is installed and operated by DTU while in this project.......The report describes the installation, configuration and data transfer for the ground-based lidar. The unit is provided by a customer but is installed and operated by DTU while in this project....

  2. STRUCTURAL SOLUTIONS AND SPECIAL FEATURES OF THE THERMAL PROTECTION ANALYSIS OF EXTERIOR WALLS OF BUILDINGS MADE OF AUTOCLAVED GAS-CONCRETE BLOCKS

    Bedov Anatolij Ivanovich

    2012-10-01

    Full Text Available Relevant structural solutions, physical and mechanical characteristics, coefficients of thermal conductivity for exterior masonry walls made of autoclaved gas-concrete blocks are provided in the article. If a single-layer wall is under consideration, an autoclaved gas-concrete block is capable of performing the two principal functions of a shell structure, including the function of thermal protection and the bearing function. The functions are performed simultaneously. Therefore, the application of the above masonry material means the design development and erection of exterior walls of residential buildings noteworthy for their thermal efficiency. In the event of frameless structures, the height of the residential building in question may be up to 5 stories, while the use of a monolithic or a ready-made frame makes it possible to build high-rise buildings, and the number of stories is not limited in this case. If the average block density is equal to 400…500 kilograms per cubic meter, the designed wall thickness is to be equal to 400 mm. Its thermal resistance may be lower than the one set in the event of the per-element design of the thermal protection (Rreq = 3.41 м2 C/Watt, in Ufa, although it will meet the requirements of the applicable regulations if per-unit power consumption rate is considered.

  3. The Upgraded Plasma Focus Installation > - The Installation >

    Krokhin, O.N.; Nikulin, V.Ya.; Babenko, B.A.; Gorbunov, D.N.; Gurei, A.E.; Kalachev, N.V.; Kozlova, T.A.; Malafeev, Yu.S.; Polukhin, S.N.; Sychev, A.A.; Tikhomirov, A.A.; Tsybenko, S.P.; Volobuev, I.V.

    1999-01-01

    The paper presents the upgraded plasma focus installation > - the installation > and some preliminary experimental results. The total energy stored in capacity bank is now 400 kJ, current - 5 MA with the rise time 3.5 μs. The investigation is targeted on the study of near electrode processes and its influence on plasma dynamics in a special operating regime of Filippov type PF - Hard X-ray regime. (author)

  4. 46 CFR 119.430 - Engine exhaust pipe installation.

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Engine exhaust pipe installation. 119.430 Section 119... INSTALLATION Specific Machinery Requirements § 119.430 Engine exhaust pipe installation. (a) The design of all... an exhaust pipe. (b) Exhaust gas must not leak from the piping or any connections. The piping must be...

  5. Study of the potential of using geocooling of an installation with vertical geothermal probes applied to an administrative building in Chiasso - final report; Etude du potentiel d'utilisation de 'geocooling' d'une installation avec sondes geothermiques verticales applique a un batiment administratif 'Minergie' a Chiasso - Rapport final

    Pahud, D.; Caputo, P.; Branca, G.; Generelli, M.

    2008-12-15

    The new office building of Brogeda-Chiasso Swiss custom has been built to satisfy the 'Minergie' standard. Low energy requirements for heating and cooling make it possible to use active concrete plates for thermal energy emission (they are called TABS in German). Further, there are ideal conditions for the integration of a geothermal system based on geocooling: a borehole heat exchanger field is coupled to a heat pump in winter and to the cooling distribution through a flat plate heat exchanger in summer. The building has been considered as a reference case in the framework of a study about geocooling applications. A dynamic system model has been developed to simulate the building, the emission of thermal energy, the technical installation and the thermal interactions between them. The simulation tool, called COOLSIM, has been developed using TRNSYS and benefits of developments and validations performed with previous simulation tools such as PILESIM2 and BRIDGESIM. A procedure has been defined to assess the technical feasibility of a system based on geocooling and to establish its sizing. A sensitivity study has been performed to assess and show the influences of the main system parameters on the system sizing. The sizing of the borehole heat exchanger field has been evaluated by determining the total borehole length of the boreholes in relation to the heat pump power and the cooling requirements that have to be met by geocooling. The most influential parameters related to thermal requirements are the heat extraction rate from the boreholes, the temperature level in the geocooling distribution and the ratio between the annual heating and cooling energy requirements. The lowest possible heat power and the highest possible temperature have to be identified. It is important to have a large enough temperature difference between the initial ground temperature and the forward fluid temperature in the cooling distribution. The annual cooling energy transferred

  6. Study of the potential of using geocooling of an installation with vertical geothermal probes applied to an administrative building in Chiasso - final report; Etude du potentiel d'utilisation de 'geocooling' d'une installation avec sondes geothermiques verticales applique a un batiment administratif 'Minergie' a Chiasso - Rapport final

    Pahud, D.; Caputo, P.; Branca, G.; Generelli, M.

    2008-12-15

    The new office building of Brogeda-Chiasso Swiss custom has been built to satisfy the 'Minergie' standard. Low energy requirements for heating and cooling make it possible to use active concrete plates for thermal energy emission (they are called TABS in German). Further, there are ideal conditions for the integration of a geothermal system based on geocooling: a borehole heat exchanger field is coupled to a heat pump in winter and to the cooling distribution through a flat plate heat exchanger in summer. The building has been considered as a reference case in the framework of a study about geocooling applications. A dynamic system model has been developed to simulate the building, the emission of thermal energy, the technical installation and the thermal interactions between them. The simulation tool, called COOLSIM, has been developed using TRNSYS and benefits of developments and validations performed with previous simulation tools such as PILESIM2 and BRIDGESIM. A procedure has been defined to assess the technical feasibility of a system based on geocooling and to establish its sizing. A sensitivity study has been performed to assess and show the influences of the main system parameters on the system sizing. The sizing of the borehole heat exchanger field has been evaluated by determining the total borehole length of the boreholes in relation to the heat pump power and the cooling requirements that have to be met by geocooling. The most influential parameters related to thermal requirements are the heat extraction rate from the boreholes, the temperature level in the geocooling distribution and the ratio between the annual heating and cooling energy requirements. The lowest possible heat power and the highest possible temperature have to be identified. It is important to have a large enough temperature difference between the initial ground temperature and the forward fluid temperature in the cooling distribution. The annual cooling energy transferred by

  7. Solar system installation at Louisville, Kentucky

    1978-01-01

    The installation of a solar space heating and domestic hot water system is described. The overall philosophy used was to install both a liquid and a hot air system retrofitted to existing office and combined warehouse building. The 1080 sq. ft. office space is heated first and excess heat is dumped into the warehouse. The two systems offer a unique opportunity to measure the performance and compare results of both air and liquid at one site.

  8. Decommissioning of offshore installations

    Oeen, Sigrun; Iversen, Per Erik; Stokke, Reidunn; Nielsen, Frantz; Henriksen, Thor; Natvig, Henning; Dretvik, Oeystein; Martinsen, Finn; Bakke, Gunnstein

    2010-07-01

    expertise and overall assessments, and is best dealt with at central level. When new regulations have entered into force, the Norwegian Radiation Protection Authority will be responsible for regulating radioactive releases and waste from the same facilities under the Pollution Control Act. This will require close coordination between the two agencies and makes it more important to transfer authority to the Climate and Pollution Agency. In addition, decommissioning of offshore facilities involves the oil and gas industry and may involve the import and export of waste, both areas where the Climate and Pollution Agency is already the competent authority. The costs of decommissioning the roughly 500 installations on the Norwegian continental shelf are uncertain, but a preliminary estimate suggests that the overall cost will be about NOK 160 billion. This estimate does not include the removal of fixed concrete substructures, since the costs of this are very uncertain at present.

  9. Safety report concerning the reactor Pegase - volume 1 - Description of the installation - volume 2 - Safety of the installations

    Lacour, J.

    1964-01-01

    In the first volume: This report is a description of the reactor Pegase, given with a view to examine the safety of the installations. The Cadarache site at which they are situated is briefly described, in particular because of the consequences on the techniques employed for building Pegase. A description is also given of the original aspects of the reactor. The independent loops which are designed for full-scale testing of fuel elements used in natural uranium-gas-graphite reactor systems are described in this report, together with their operational and control equipment. In the second volume: In the present report are examined the accidents which could cause damage to the Pegase reactor installation. Among possible causes of accidents considered are the seismicity of the region, an excessive power excursion of the reactor and a fracture in the sealing of an independent loop. Although all possible precautions have been taken to offset the effects of such accidents, their ultimate consequences are considered here. The importance is stressed of the security action and regulations which, added to the precautions taken for the construction, ensure the safety of the installations. (authors) [fr

  10. Design/Installation and Structural Integrity Assessment of Bethel Valley Low-Level Waste Collection and transfer system upgrade for Building 2649 (Transported Waste Receiving Facility) at Oak Ridge National Laboratory

    1995-01-01

    This document covers the design aspects of the new tank system and certifies that the design has sufficient structural integrity and is acceptable for storing or treating hazardous and/or radioactive substances. This issue identifies specific activities that must be completed during fabrication, installation, and testing of the new tank system in order to prove compliance of the final installation with governing requirements. The assessment is responsive to the Environmental Restoration Agreement for the Oak Ridge Reservation

  11. Positional Arrangements of Waste Exhaust Gas Ducts of C-Type Balanced Chimney Heating Devices on Building Façades

    Erkan AVLAR

    2009-01-01

    Full Text Available In Turkey today, with the increase in availability of natural gas,detached heating devices are being preferred over existingheating devices. Due to the lack of chimneys in existing buildingsin Turkey or the presence of chimneys that fail to conformto standards, the use of C-type balanced chimney devices has increased.C-type balanced chimney devices take the combustionair directly from the outside by a specific air duct as detachedheating equipment, with enclosed combustion chambers anda specific waste gas exhaust duct, and they are ventilated independentlyof the field of equipment. Because of their essentiality,the use of a chimney is not required in these devices;the waste gas is exhausted through walls, windows, doors, orbalconies. The natural gas is a clean fossil fuel that requires nostorage in buildings and is easy to use. However, water vapor,carbon dioxide and nitrogen oxides are produced by the combustionof natural gas. It is widely known that high concentrationsof these products can have some adverse effects onhumans such as dizziness, headaches and nausea. As a result,the waste products could recoil through wall openings on thefaçade to create unhealthy indoor environments that could bedangerous to human health. Therefore, the importance of standardsand regulations about the positional arrangements of thewaste gas exhaust ducts of C-type balanced chimney devices onbuilding façades is increasing. In this research, we analyze thestudies of the Institution of Turkish Standards, Chamber of MechanicalEngineers, gas distribution companies, municipalitiesand authorized firms and compare the criteria to determine thenecessary application method. According to our comparison ofthe references accessed, the criteria are not uniform.

  12. LHC installation planning

    Weisz, S

    2005-01-01

    installation of the general services, the installation of the cryogenic line (QRL), the installation of the machine elements and the hardware commissioning. While the installation of the general services is now almost finished (see presentation by Katy Foraz and Serge Grillot), several problems and delays with the QRL made it unavoidable to revise the installation strategy and to schedule a number tasks in parallel. A new compressed installation planning has been issued, that fulfils the strategic objectives and allows starting new activities with minimal delays in sectors 7-8 and 8-1. However, the shortcuts that are introduced increase the level of risk that we will have to face and the coordination of such a large and complex variety of simultaneous activities makes the project even more challenging. The document will describe how the input from the different equipment groups is taken into account by the master schedule planning team with respect to equipment availability and production as well as logistics...

  13. Fuel cells: new technology of natural gas for energetical building; Pilas de combustible: nueva tecnologia de gas natural para edificios energeticamente autoabastecidos

    Gutierrez, A. M.

    2000-07-01

    Fuel Cells have emerged in the last decade as one of the most promising new and sustainable natural gas technologies for meeting the energy needs of all the economy sectors into the 21st century. Fuel Cells are an environmentally clean, quiet, and highly efficient method for generating electricity and heat from natural gas. A fuel cell is an electrochemical device that converts the chemical energy of a fuel directly to usable energy (electricity and heat) without combustion. For this reason, the application and use of the fuel cell technology may be the most important technological advancement of the next century. At the beginning of the 2000 year Sociedad de Gas de Euskadi, s. a. started a demonstration project in favour of the high-temperature planar solid oxide fuel cell (SOFC) for domestic micro-CHP utilization. This type is certainly most exacting from the materials standpoint, and it offers the advantage of uncomplicated fuel pretreatment. (Author)

  14. Methyl chloride via oxyhydrochlorination of methane: A building block for chemicals and fuels from natural gas. Environmental assessment

    1996-09-01

    DOE's natural gas mission, in partnership with its stakeholders, is to undertake and promote activities to maximize the Nation's ability to supply, transport, and use natural gas to encourage economic growth, enhance energy interests security, and improve the environment. In implementing this mission, DOE has been involved in promoting domestic natural gas as a clean, abundant, and reliable source of energy. In particular, DOE is interested in technologies capable of converting natural gas to other valuable resources, such as transportation fuels, hydrogen, and premium chemicals. The purpose of the proposed action is to further examine the potential of one such technology for natural gas conversion. Over the past five years, DOE's Pittsburgh Energy Technology Center has supported a research program to determine the feasibility of producing methyl chloride (CH 3 Cl), a key ingredient used in the silicone industry, directly from methane (the primary component of natural gas) via an oxyhydrochlorination (OHC) process. As a result of this research program the OHC process is now ready for further development. The proposed action would advance the OHC natural gas conversion technology to an integrated engineering-scale process at the Dow Corning plant in Carrollton, Kentucky

  15. Electrical installation calculations basic

    Kitcher, Christopher

    2013-01-01

    All the essential calculations required for basic electrical installation workThe Electrical Installation Calculations series has proved an invaluable reference for over forty years, for both apprentices and professional electrical installation engineers alike. The book provides a step-by-step guide to the successful application of electrical installation calculations required in day-to-day electrical engineering practice. A step-by-step guide to everyday calculations used on the job An essential aid to the City & Guilds certificates at Levels 2 and 3Fo

  16. Electrical installation calculations advanced

    Kitcher, Christopher

    2013-01-01

    All the essential calculations required for advanced electrical installation workThe Electrical Installation Calculations series has proved an invaluable reference for over forty years, for both apprentices and professional electrical installation engineers alike. The book provides a step-by-step guide to the successful application of electrical installation calculations required in day-to-day electrical engineering practiceA step-by-step guide to everyday calculations used on the job An essential aid to the City & Guilds certificates at Levels 2 and 3For apprentices and electrical installatio

  17. Electrical installations and regulations

    Whitfield, J F

    1966-01-01

    Electrical Installations and Regulations focuses on the regulations that apply to electrical installations and the reasons for them. Topics covered range from electrical science to alternating and direct current supplies, as well as equipment for providing protection against excess current. Cables, wiring systems, and final subcircuits are also considered, along with earthing, discharge lighting, and testing and inspection.Comprised of 12 chapters, this book begins with an overview of electrical installation work, traits of a good electrician, and the regulations governing installations. The r

  18. IMCOM LONWORKS Building Automation Systems Implementation Strategy

    Schwenk, David M; Bush, Joseph; Hughes, Lucie M; Briggs, Stephen; White, Will

    2007-01-01

    Army Installations often expand their use of digital control systems for heating, ventilating, and air conditioning and other mechanical and electrical building systems on a building-by-building basis...

  19. Introduction: Green Building Handbook

    Van Wyk, Llewellyn V

    2010-08-01

    Full Text Available By recognising the specific environmental challenges facing South Africa, mindful of the government‘s commitment to reducing South Africa‘s Greenhouse gas emissions, and acknowledging the need to build social cohesion, the Green Building Handbook...

  20. Update on Geothermal Direct-Use Installations in the United States

    Beckers, Koenraad J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Young, Katherine R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Snyder, Diana M. [Georgia State University

    2017-02-15

    Direct-use of geothermal energy currently has limited penetration in the United States, with an estimated installed capacity of about 500 MWth, supplying on the order of 0.01% of the total annual U.S. heat demand (about 30 EJ). We see higher penetration levels in other countries such as Iceland (about 90%) and Hungary (2.5%). An updated database of geothermal direct-use systems in the U.S. has been compiled and analyzed, building upon the Oregon Institute of Technology (OIT) Geo-Heat Center direct-use database. Types of directuse applications examined include hot springs resorts and pools, aquaculture farms, greenhouses, and district heating systems, among others; power-generating facilities and ground-source heat pumps were excluded. Where possible, the current operation status, open and close dates, well data, and other technical data were obtained for each entry. The database contains 545 installations, of which 407 are open, 108 are closed, and 30 have an unknown status. Spas are the most common type of installation, accounting for 50% of installations by number. Aquaculture installations (46 out of 407 open installations) account for the largest percentage (26%) of installed capacity in operation (129 MWth out of 501 MWth). Historical deployment curves show the installed capacity significantly increased in the 1970s and 1980s mainly due to development of geothermal district heating, aquaculture, and greenhouse systems. Since the 2000s, geothermal direct-use development appears to have slowed, and the number of sites in operation decreased due to closures. Case studies reveal multiple barriers to geothermal direct-use implementation and operation, including 1) existence of an information gap among stakeholders, developers, and the general public, 2) competition from cheap natural gas, and 3) the family-owned, small-scale nature of businesses might result in discontinuation among generations.

  1. Underground gas storage Uelsen: Findings from planning, building and commissioning. Part 1: Deposit; Untertagegasspeicher Uelsen: Erkenntnisse aus Planung, Bau und Inbetriebnahme. Teil 1: Lagerstaette

    Wallbrecht, J.; Beckmann, H.; Reiser, H.; Wilhelm, R. [BEB Erdgas und Erdoel GmbH, Hannover (Germany)

    1998-12-31

    The underground gas storage at Uelsen which was built as a H-gas storage in a former variegated sandstone gasfield in Western Lower Saxony close to the town of Nordhorn has added to the gas supply system of the BEB Erdgas and Erdoel GmbH. The underground storage is connected to the Bunde-Rheine transport pipeline BEB-grid gas system by a 27 km pipeline and is a consequent expansion of BEB`s underground storage/transport system. Planning, building and commissioning were handled by BEB. Findings to date are described. [Deutsch] Der Untertagegasspeicher (UGS) Uelsen, der in einem ehemaligen Buntsandstein Gasfeld im westlichen Niedersachsen in der Naehe der Stadt Nordhorn als H-Gasspeicher eingerichtet wurde, hat die BEB Erdgas und Erdoel GmbH eine weitere Staerkung ihres Gasversorgungssystems erreicht. Der UGS Uelsen ist ueber eine 27 km lange Anbindungsleitung mit der zum BEB - Ferngasleitungssystems gehoerenden Bunde-Rheine Transportleitung verbunden und stellt eine konsequente Erweiterung des BEB Untertagegasspeicher-/Transportsystems dar. Planung, Bau und Inbetriebnahme erfolgten durch BEB im Rahmen einer integrierten bereichsuebergreifenden Projektbearbeitung. Die hierbei gewonnenen Erkenntnisse werden im Folgenden fuer den Untertagebereich dargestellt. (orig.)

  2. Installation dismantling system, working process and hood utilizable in this system

    Poirier, J.C.; Mulcey, P.; Morel, P.; Vavasseur, C.

    1989-01-01

    The system for dismantling an installation under a controlled atmosphere is made by a tool polluting the atmosphere, a gas blanket creating a continement zone around the tool, an extractor removing polluted gas from the zone, a purifier for the extracted gas and a controller regulating the flow of gas in the blanket and keeping the installation at constant pressure [fr

  3. Designing Software-Based Interactive Installations

    Andreasen, Troels; Juul, Niels Christian; Rosendahl, Mads

    2014-01-01

    of the installation using tools like sketching or storyboarding. The design involves a clarification of available and appropriate building blocks, as well as the linking of these blocks to provide an architectural framework comprising the intended external behavior. The construction phase takes a component...

  4. VERA 3.5 Installation Guide

    Bartlett, Roscoe A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Baird, Mark L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Berrill, Mark A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Kulesza, Joel A. [Univ. of Michigan, Ann Arbor, MI (United States); Mervin, Brenden T. [Electric Power Research Inst. (EPRI), Charlotte, NC (United States)

    2016-08-16

    This guide describes the structure and setup of the standard VERA development environment (VERA Dev Env) and standard VERA Third Party Libraries (TPLs) that need to be in place before installing many of the VERA simulation components. It describes everything from the initial setup on a new machine to the final build, testing, and installation of VERA components. The goal of this document is to describe how to create the directories and contents outlined in Standard VERA Dev Env Directory Structure and then obtain the remaining VERA source and build, test, and install any of the necessary VERA components on a given system. This document describes the process both for a development version of VERA and for a released tarball of the VERA sources.

  5. VERA 3.5 Installation Guide

    Bartlett, Roscoe A.; Baird, Mark L.; Berrill, Mark A.; Kulesza, Joel A.; Mervin, Brenden T.

    2016-01-01

    This guide describes the structure and setup of the standard VERA development environment (VERA Dev Env) and standard VERA Third Party Libraries (TPLs) that need to be in place before installing many of the VERA simulation components. It describes everything from the initial setup on a new machine to the final build, testing, and installation of VERA components. The goal of this document is to describe how to create the directories and contents outlined in Standard VERA Dev Env Directory Structure and then obtain the remaining VERA source and build, test, and install any of the necessary VERA components on a given system. This document describes the process both for a development version of VERA and for a released tarball of the VERA sources.

  6. Underground gas storage Uelsen: Findings from planning, building and commissioning the surface buildings and structures; Untertagegasspeicher (UGS) Uelsen: Erkenntnisse aus Planung, Bau und Inbetriebnahme der obertaegigen Anlagen

    Focke, H.; Brueggmann, R.; Mende, F.; Steinkraus, D.; Wauer, R. [BEB Erdgas und Erdoel GmbH, Hannover (Germany)

    1998-12-31

    The article describes the concepts of the plants and equipment and the specific features of the underground storage at Uelsen. The underground storage will be purpose-built as an H-gas storage in a nearly depleted sandstone deposit. At a nominal deliverability of 250.000 cubic m/h (Vn) the storage at Uelsen has more potential for expansion. This potential was taken into account by designing appropriate pressure stages, capacities, performance characteristics and space. (orig.). [Deutsch] Die nachfolgende Veroeffentlichung stellt das anlagentechnische Grundkonzept und die spezifischen Besonderheiten des UGS Uelsen dar. Der im suedwestlichen Niedersachsen als H-Gasspeicher in einer nahezu ausgefoerderten Buntsandsteinlagerstaette eingerichtete UGS Uelsen wird in mehreren Ausbaustufen bedarfsgerecht fertiggestellt. Bei einer Nennentnahmekapazitaet von 450.000 m{sup 3}/h (Vn) und einer Nenninjektionsleistung von 250.000 m{sup 3}/h (Vn) weist der UGS Uelsen noch weiteres Potential fuer Erweiterungen auf. Dieses Ausbaupotential wurde bei der Planung und dem Bau der bestehenden Anlagen durch Festlegung entsprechender Druckstufen, Kapazitaeten, Leistungsgroessen und Platzanordnungen beruecksichtigt. (orig.)

  7. Radon gas inside historical buildings in the city of Cordoba; Gas {sup 222}Rn en construcciones historicas de la ciudad de Cordoba

    Perez, R; Germanier, A; Rubio, M [CEPROCOR, Cordoba (Argentina); Sbarato, D; Zappino, R [Observatorio Ambiental de la Municipalidad de Cordoba, Cordoba (Argentina)

    1998-07-01

    Full text: In this work measurements of the Radon ({sup 222}Rn) concentration in the inside of historical buildings which date back to the end of the 17th and the beginning of the 18th Centuries have been carried out in the city of Cordoba (Argentina). Meteorological factors such as room temperature and atmospheric pressure have not shown to affect, to a great extent, the results obtained. By comparing the concentration of {sup 222}Rn in environments at different levels we inferred that the soil underlying the buildings does not represent an important source of {sup 222}Rn. The main occurrence of the element was found in room walls, which shows that local building materials are an important source of {sup 222}Rn. Among the materials used in these buildings are granitic rocks, and to a lesser extent, lime, sand and marble. The {sup 222}Rn concentrations recorded in some of the rooms surveyed reach values which are close to the minimum intervene level set by international standards in 4pCi/l. The study of the effects of ventilation in the concentration of {sup 222}Rn allows us to conclude that its values decrease to accepted levels by means of a natural and efficient ventilation of the rooms. (author) [Spanish] Texto completo: En este trabajo se han realizado mediciones de la concentracion de radon (radon 222) en el interior de edificios de la ciudad de Cordoba que datan de finales del siglo XVII y comienzos del siglo XVIII. Las concentraciones de radon 222 se determinaron con un detector pasivo Radon Monitor 05-418, marca Victoreen. El mismo consta de una camara de difusion electrostatica y un detector de estado solido (Si) de juntura difundida. No se observo, en los resultados obtenidos, influencias causadas por factores meteorologicos como la temperatura ambiente y la presion atmosferica. Por comparacion de la concentracion de radon 222 en ambientes ubicados en distintas plantas se dedujo que el suelo subyacente bajo los edificios representa una fuente secundaria

  8. Methods for measuring gas emissions from naturally ventilated livestock buildings: Developments over the last decade and perspectives for improvement

    Ogink, N.W.M.; Mosquera Losada, J.; Calvet, S.; Zhang, G.

    2013-01-01

    The objectives of this paper are: 1) to give an overview of the development of methods for measuring emission rates from naturally ventilated livestock buildings over the last decade, 2) to identify and evaluate strengths and weaknesses, 3) to summarise and conclude the current state-of-art of

  9. Decreasing of energy consumption for space heating in existing residential buildings; Combined geothermal and gas district heating systems

    Rosca, Marcel

    2000-01-01

    The City of Oradea, Romania, has a population of about 230 000 inhabitants. Almost 70% of the total heat demand, including industrial, is supplied by a classical East European type district heating system. The heat is supplied by two low grade coal fired co-generation power plants. The oldest distribution networks and substitutions, as well as one power plant, are 35 years old and require renovation or even reconstruction. The geothermal reservoir located under the city supplies at present 2,2% of the total heat demand. By generalizing the reinjection, the production can be increased to supply about 8% of the total heat demand, without any significant reservoir pressure or temperature decline over 25 years. Another potential energy source is natural gas, a main transport pipeline running close to the city. Two possible scenarios are envisaged to replace the low grade coal by natural gas and geothermal energy as heat sources for Oradea. In one scenario, the geothermal energy supplies the heat for tap water heating and the base load for space heating in a limited number of substations, with peak load being produced by natural gas fired boilers. In the other scenario, the geothermal energy is only used for tap water heating. In both scenarios, all substations are converted into heat plants, natural gas being the main energy source. The technical, economic, and environmental assessment of the two proposed scenarios are compared with each other, as well as with the existing district heating system. Two other possible options, namely to renovate and convert the existing co-generation power plants to natural gas fired boilers or to gas turbines, are only briefly discussed, being considered unrealistic, at least for the short and medium term future. (Author)

  10. A supermolecular building layer approach for gas separation and storage applications: the eea and rtl MOF platforms for CO 2 capture and hydrocarbon separation

    Chen, Zhijie

    2015-02-11

    The supermolecular building layer (SBL) approach was employed to deliberately synthesize five novel metal–organic frameworks (1–5) with an exposed array of amide or amine functionalities within their pore system. The ability to decorate the pores with nitrogen donor moieties offers potential to evaluate/elucidate the structure–adsorption property relationship. Two MOF platforms, eea-MOF and rtl-MOF, based on pillaring of kgm-a or sql-a layers with heterofunctional 3-connected organic building blocks were targeted and constructed to purposely introduce and expose the desired amide or amine functionalities. Interestingly, gas adsorption properties of eea-MOF-4 (1) and eea-MOF-5 (2) showed that by simply altering the nitrogen donor position within the ligand, it is possible to relatively reduce the pore size of the related eea-MOF material and subsequently increase the associated CO2 uptake. The slightly confined pore space in 2, relative to 1, has enabled an enhancement of the pore local charge density and thus the observed relative increase in the CO2 and H2 isosteric heat of adsorption (Qst). In addition, light hydrocarbon adsorption studies revealed that 2 is more selective toward C2H6 and C3H8 over CH4 than 1, as exemplified for C2H6 : CH4 (5 : 95) or C3H8 : CH4 (5 : 95) binary gas mixtures.

  11. 3D Projection Installations

    Halskov, Kim; Johansen, Stine Liv; Bach Mikkelsen, Michelle

    2014-01-01

    Three-dimensional projection installations are particular kinds of augmented spaces in which a digital 3-D model is projected onto a physical three-dimensional object, thereby fusing the digital content and the physical object. Based on interaction design research and media studies, this article ...... Fingerplan to Loop City, is a 3-D projection installation presenting the history and future of city planning for the Copenhagen area in Denmark. The installation was presented as part of the 12th Architecture Biennale in Venice in 2010....

  12. TESLA accelerator installation

    Neskovic, N.; Ostojic, R.; Susini, A.; Milinkovic, Lj.; Ciric, D.; Dobrosavljevic, A.; Brajuskovic, B.; Cirkovic, S.; Bojovic, B.; Josipovic, M.

    1992-01-01

    The TESLA accelerator Installation is described. Its main parts are the VINCY Cyclotron, the multiply charged heavy-ion mVINIS Ion Source, and the negative light-ion pVINIS Ion Source. The Installation should be the principal installation of a regional center for basic and applied research in nuclear physics, atomic physics, surface physics and solid state physics, for production of radioisotopes, for research and therapy in nuclear medicine. The first extraction of the ion beam from the Cyclotron is planned for 1995. (R.P.) 3 refs.; 1 fig

  13. NRC new sustainable building

    Semczyszyn, D.

    2004-01-01

    'Full text:' The National Research Council Institute For Fuel Cell Innovation is relocating to a purpose-built 71,343 sq. Ft. (6598 sq. M) Research, Testing, Evaluation, and Industry Incubation Facility in the spring of 2006. The new facility will contain Hydrogen-ready laboratories, the existing relocated Hydrogen Safe Environmental Test Chamber, a hydrogen vehicle maintenance bay, a hydrogen vehicle refuelling station, and the following demonstration projects and features: 1. A Ground Source Heat Pump: This long-proven natural-source heating and cooling technology to provide climate control for the new IFCI's atrium and galleria. It is being designed by Keen Engineering of North Vancouver, BC. 2. 5 KW Solid Oxide Fuel Cell System: Fuelled by natural gas and in the future, from biomass, the fuel cell will also produce approximately 15 kW of waste heat, which will be captured and used to supply heat for the building. The Solid Oxide Fuel Cell will be supplied by Fuel Cell Technologies in Kingston, ON. 3. LEED Building certification: Attaining LEED 'green building' certification is considered an important complement to the plans for the new NRC-IFCI, because it will provide respected third-party verification of government's commitment to efficient building design and construction. Project architects Bunting Coady of Vancouver, BC believe the IFCI has strong potential to earn gold LEED certification. 4. Photovoltaic hydrogen source for back-up power fuel cell system: A photovoltaic array will capture energy from sunlight to power an electrolyzer that will produce and store hydrogen for a PEM fuel cell emergency backup power system. The electrolyzer will be provided by Hydrogenics of Mississauga, ON. Photovoltaics are being designed and installed by the British Columbia Institute of Technology. (author)

  14. 78 FR 26354 - Transcontinental Gas Pipeline Company, LLC; Notice of Intent to Prepare an Environmental Impact...

    2013-05-06

    ... proposes to: Add an incremental 6,540 horsepower (hp) of compression at its existing Compressor Station 195 in York County, Pennsylvania by: installing a new 35 kilovolt substation, variable frequency drive building, and associated coolers; replacing three existing natural gas- fired reciprocating engines and...

  15. 30 CFR 817.180 - Utility installations.

    2010-07-01

    ... PERMANENT PROGRAM PERFORMANCE STANDARDS PERMANENT PROGRAM PERFORMANCE STANDARDS-UNDERGROUND MINING ACTIVITIES § 817.180 Utility installations. All underground mining activities shall be conducted in a manner...; oil, gas, and coal-slurry pipelines, railroads; electric and telephone lines; and water and sewage...

  16. Construction, fabrication, and installation

    1992-05-01

    This standard specifies the construction, fabrication, and installation requirements that apply to concrete containment structures of a containment system designated as class containment components, parts and appurtenances for nuclear power plants

  17. Visiting the SPS installation

    1975-01-01

    ...., Guenther Loehr, Hans Horisberger walk along the SPS tunnel: here, on the right, an absorber block of 22 tons for beam dumping in the external beam lines. The chariot serves for the installation of the block.

  18. Biggest semiconductor installed

    2008-01-01

    Scientists and technicians at the European Laboratory for Particle Physics, commonly known by its French acronym CERN (Centre Europen pour la Recherche Nuclaire), have completed the installation of the largest semiconductor silicon detector.

  19. The expert Kurt Reithaar on building safety: 'More and more technical installations for less money'. Fachmann Kurt Reithaar zum Thema Sicherheit bei Gebaeuden: 'Immer mehr Technik fuer weniger Geld'

    Reithaar, K [Cerberus AG, Maennedorf (Switzerland); Aeberli, O E

    1990-06-01

    Safety requirements differ largely depending on the kind of building to be protected. In case of industrial buildings the question of data protection is of great importance. In order to comply with this requirement depending on the risk licenses by invitation are used. In industrial buildings also fire protection is to the fore. The weakest factor of safety systems surely is the human factor, i.e. incorrect operation. Therefore sufficient instruction and training of the operators is very important. In order to ensure extensive protection several different technical solutions are necessary. Here microprocessor engineering plays a decisive role. (BWI).

  20. Safety report concerning the reactor Pegase - volume 1 - Description of the installation - volume 2 - Safety of the installations; Rapport de surete du reacteur pegase - tome 1 - Description des installations - tome 2 - Surete des installations

    Lacour, J. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Legoin, P. [S.E.M. Hispano-Suiza, 92 - Colombes (France)

    1964-07-01

    In the first volume: This report is a description of the reactor Pegase, given with a view to examine the safety of the installations. The Cadarache site at which they are situated is briefly described, in particular because of the consequences on the techniques employed for building Pegase. A description is also given of the original aspects of the reactor. The independent loops which are designed for full-scale testing of fuel elements used in natural uranium-gas-graphite reactor systems are described in this report, together with their operational and control equipment. In the second volume: In the present report are examined the accidents which could cause damage to the Pegase reactor installation. Among possible causes of accidents considered are the seismicity of the region, an excessive power excursion of the reactor and a fracture in the sealing of an independent loop. Although all possible precautions have been taken to offset the effects of such accidents, their ultimate consequences are considered here. The importance is stressed of the security action and regulations which, added to the precautions taken for the construction, ensure the safety of the installations. (authors) [French] Dans le volume 1: Ce rapport est une description du reacteur Pegase, afin d'examiner la surete des installations. Le site de CADARACHE ou elles sont situees, a ete sommairement decrit, en particulier, a cause des consequences sur les techniques mises en oeuvre pour la realisation de Pegase. Nous nous sommes egalement attache a decrire les aspects originaux du reacteur. Les boucles autonomes destinees a tester en vraie grandeur des elements combustibles de la filiere uranium naturel graphite-gaz, ainsi que leurs dispositifs de controle et d'exploitation, figurent egalement dans ce rapport. Dans le volume 2: Dans le present rapport, nous examinons des accidents pouvant endommager des installations du reacteur Pegase. Les origines d'accidents examines

  1. Safety report concerning the reactor Pegase - volume 1 - Description of the installation - volume 2 - Safety of the installations; Rapport de surete du reacteur pegase - tome 1 - Description des installations - tome 2 - Surete des installations

    Lacour, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires; Legoin, P [S.E.M. Hispano-Suiza, 92 - Colombes (France)

    1964-07-01

    In the first volume: This report is a description of the reactor Pegase, given with a view to examine the safety of the installations. The Cadarache site at which they are situated is briefly described, in particular because of the consequences on the techniques employed for building Pegase. A description is also given of the original aspects of the reactor. The independent loops which are designed for full-scale testing of fuel elements used in natural uranium-gas-graphite reactor systems are described in this report, together with their operational and control equipment. In the second volume: In the present report are examined the accidents which could cause damage to the Pegase reactor installation. Among possible causes of accidents considered are the seismicity of the region, an excessive power excursion of the reactor and a fracture in the sealing of an independent loop. Although all possible precautions have been taken to offset the effects of such accidents, their ultimate consequences are considered here. The importance is stressed of the security action and regulations which, added to the precautions taken for the construction, ensure the safety of the installations. (authors) [French] Dans le volume 1: Ce rapport est une description du reacteur Pegase, afin d'examiner la surete des installations. Le site de CADARACHE ou elles sont situees, a ete sommairement decrit, en particulier, a cause des consequences sur les techniques mises en oeuvre pour la realisation de Pegase. Nous nous sommes egalement attache a decrire les aspects originaux du reacteur. Les boucles autonomes destinees a tester en vraie grandeur des elements combustibles de la filiere uranium naturel graphite-gaz, ainsi que leurs dispositifs de controle et d'exploitation, figurent egalement dans ce rapport. Dans le volume 2: Dans le present rapport, nous examinons des accidents pouvant endommager des installations du reacteur Pegase. Les origines d'accidents examines comprennent la seismicite

  2. Fort Carson Building 1860 Biomass Heating Analysis Report

    Hunsberger, Randolph [National Renewable Energy Lab. (NREL), Golden, CO (United States); Tomberlin, Gregg [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gaul, Chris [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    As part of the Army Net-Zero Energy Installation program, the Fort Carson Army Base requested that NREL evaluate the feasibility of adding a biomass boiler to the district heating system served by Building 1860. We have also developed an Excel-spreadsheet-based decision support tool--specific to the historic loads served by Building 1860--with which users can perform what-if analysis on gas costs, biomass costs, and other parameters. For economic reasons, we do not recommend adding a biomass system at this time.

  3. Preliminary project of installation for separation tubes tests-ITTS

    Rocha, Z.

    1984-01-01

    A consolidation of actual ideas about installation, entitled ''Installation to separation tubes tests-ITTS'', expected to CDTN is presented. The project bases, the testing to be realized, the procedures to be obeyed during the operation, the components and the space required by installation and auxiliary equipments, the presumable origin of components (nacional and international), including a preliminary list of building and operation costs are described. (author) [pt

  4. The liberalization of the European gas sector and the strategic positioning of firms: A dynamic approach for corporate competence building

    Avadikyan, A.; Amesse, F.; Cohendet, P.; Heraud, J-A.

    2002-01-01

    A framework to explain how competitive changes occurring in one sector can affect both the dynamics of required competencies and the frontiers with adjacent sectors is proposed. When applied to the natural gas sector, the results provide a better understanding of how competencies in the sector evolve according to the new market structure and the strategic movements engaged in by the different players. The proposed framework combines the two approaches -- evolution and strategy -- to show that a firm's competencies define both membership in a specific sector and its distinctiveness from its competitors. To define the strategic positioning process the concept of core competencies is introduced, i.e. competencies developed by firms through their specific history which, when combined in a specific manner with new competencies could give them sustainable competitive advantage. Finally, the authors explain the concept of dynamic capabilities, which rely on a set of organizational and strategic processes needed to integrate, develop and create new competencies in order to initiate, or to adapt to market changes. The final conclusion is that the recent liberalization of the European gas and power sectors weakened institutional entry barriers, a phenomenon which compelled operators traditionally protected by regional or national monopolies to compete with other potential actors. With specific reference to the gas, power and oil industries it is stated that if they had relatively clear frontiers in the past, these frontiers have now become increasingly permeable. However, this weakening of institutional barriers has a beneficial consequence: it allows companies to deploy strategies to take advantage of new growth and rent appropriation opportunities. Examples of adaptation by European oil companies, power companies and natural gas firms are used to illustrate the principles embodied in the proposed framework. 18 refs., 1 fig

  5. Capping off installation

    2006-01-01

    Installation of the cathode strip chambers for the muon system on the CMS positive endcap has been completed. Technicians install one of the last muon system cathode strip chambers on the CMS positive endcap. Like successfully putting together the pieces of a giant puzzle, installation of the muon system cathode strip chambers on one of the CMS endcaps has been completed. Total installation of the cathode strip chambers (CSC) is now 91 percent complete; only one ring of chambers needs to be mounted on the remaining endcap to finish installation of the entire system. To guarantee a good fit for the 468 total endcap muon system CSCs, physicists and engineers from the collaboration spent about 10 years carefully planning the design. The endcap muon system's cables, boxes, pipes and other parts were designed and integrated using a 3D computerized model. 'It took a long time to do all the computer modelling, but in the long run it saved us an enormous amount of time because it meant that everything fit together,...

  6. 46 CFR 115.702 - Installation tests and inspections.

    2010-10-01

    ... CERTIFICATION Repairs and Alterations § 115.702 Installation tests and inspections. Whenever a launching appliance, survival craft, rescue boat, fixed gas fire extinguishing system, machinery, fuel tank, or...

  7. 49 CFR 192.357 - Customer meters and regulators: Installation.

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meters and regulators: Installation. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.357 Customer meters and regulators: Installation. (a...

  8. 49 CFR 192.359 - Customer meter installations: Operating pressure.

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Customer meter installations: Operating pressure... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Customer Meters, Service Regulators, and Service Lines § 192.359 Customer meter installations: Operating pressure...

  9. 46 CFR 182.430 - Engine exhaust pipe installation.

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Engine exhaust pipe installation. 182.430 Section 182... 100 GROSS TONS) MACHINERY INSTALLATION Specific Machinery Requirements § 182.430 Engine exhaust pipe... equipment might come in contact with an exhaust pipe. (b) Exhaust gas must not leak from the piping or any...

  10. Python Introduction and Installation

    William J. Turkel

    2012-07-01

    Full Text Available This first lesson in our section on dealing with Online Sources is designed to get you and your computer set up to start programming. We will focus on installing the relevant software – all free and reputable – and finally we will help you to get your toes wet with some simple programming that provides immediate results. In this opening module you will install the Python programming language, the Beautiful Soup HTML/XML parser, and a text editor. Screencaps provided here come from Komodo Edit, but you can use any text editor capable of working with Python. Here’s a list of other options: Python Editors. Once everything is installed, you will write your first programs, “Hello World” in Python and HTML.

  11. Questions for the nuclear installations inspectorate

    Conroy, C.; Flood, M.; MacRory, R.; Patterson, W.C.

    1976-01-01

    The responsibilities of the Nuclear Installations Inspectorate are considered, and the responsibilities of other bodies for (a) reprocessing and enrichment, and (b) security. Questions for the Nuclear Installations Inspectorate are then set out under the following heads: general (on such topics as vandalism, sabotage, threats, security, reactor incidents); magnox reactors; corrosion; advanced gas-cooled reactor; steam generating heavy water reactor; fast breeder reactor; reproces-sing and waste. Most of the questions are concerned with technical problems that have been reported or might possibly arise during construction or operation, affecting the safety of the reactor or process. (U.K.)

  12. Python Introduction and Installation

    William J. Turkel; Adam Crymble

    2012-01-01

    This first lesson in our section on dealing with Online Sources is designed to get you and your computer set up to start programming. We will focus on installing the relevant software – all free and reputable – and finally we will help you to get your toes wet with some simple programming that provides immediate results. In this opening module you will install the Python programming language, the Beautiful Soup HTML/XML parser, and a text editor. Screencaps provided here come from Komodo ...

  13. Logistics of LEP installation

    Genier, C.; Capper, S.

    1988-01-01

    The size of the LEP project, coupled with the tight construction schedules, calls for organized planning, logistics, monitoring and control. This is being carried out at present using tools such as ORACLE the Relational Database Management System, running on a VAX cluster for data storage and transfer, micro-computers for on-site follow-up, and PC's running Professional ORACLE, DOS and XENIX linked to a communications network to receive data feedback concerning transport and handling means. Following over 2 years of installations, this paper presents the methods used for the logistics of installation and their results

  14. Electrical installations technology

    Whitfield, J F

    1968-01-01

    Electrical Installations Technology covers the syllabus of the City and Guilds of London Institute course No. 51, the "Electricians B Certificate”. This book is composed of 15 chapters that deal with basic electrical science and electrical installations. The introductory chapters discuss the fundamentals and basic electrical principles, including the concept of mechanics, heat, magnetic fields, electric currents, power, and energy. These chapters also explore the atomic theory of electric current and the electric circuit, conductors, and insulators. The subsequent chapter focuses on the chemis

  15. Field installation and maintenance

    Prebble, R.E.

    1981-01-01

    The use of a neutron moisture meter for the determination of the water content of soil necessitates the installation of an access tube down which the probe can be lowered. Errors in neutron count rate will be introduced if water enters the air gap between a loose fitting tube and the soil. Errors may also be caused by changes in the soil structure resulting from the techniques for soil removal and from driving the access hole. Access tube materials and dimensions, methods of installation and maintenance of the site are discussed

  16. Efectos de la instalación de un gasoducto sobre algunas propiedades del suelo superficial y la cobertura vegetal en el NE de Chubut Gas-pipeline installation effects on superficial soil properties and vegetation cover in Northeastern Chubut

    Esteban Kowaljow

    2008-07-01

    , sobre todo, por la baja calidad de los sedimentos extraídos de los horizontes inferiores de la zanja.In this work we describe the impact of a gas-pipeline installation and the replacing of the material removed in part of the clear-cutting, on some physical and chemical properties of the soils and vegetation in three ecological sites of Northeastern Chubut. In these sites we identified four different areas: area 1, clear-cut strip, where the traffic of heavy machinery was intense; area 2, clear-cut strip, with soil and vegetation replaced; and other two areas in the undisturbed adjacent steppe: mounds associated to shrubs and mound interspaces. The highest bulk densities were recorded in area 1 and in the mound interspaces (1.43 Mg m-3. The penetrometer resistance was significantly higher in the areas 1 and 2, recording values higher than 1 MPa. The infiltration rate was much higher in the mound (261 mm h-1 than in the other areas. The infiltration rate of area 2 (85 mm h-1 was higher than that of area 1 (35 mm h-1 and the mound interspaces (50 mm h-1. Total nitrogen and organic carbon content in soils of the areas 1 and 2 were similar to those of the mound interspaces and significantly lower than those of the mound, except in the area 2 of one ecological site. Clear-cut and topsoil removal, and the subsequent traffic of heavy machinery caused by underground gas-pipeline installation produced a strong impact on the physical properties of these soils. The main limitation in the highly disturbed soils was the decrease in the infiltration rate, mainly due to high compaction and low porosity. This may in part explain the slow vegetation cover recovery in the area 1. The replacement of the stripped sediment and vegetation on the disturbed strip did not improve the recovery of the vegetation cover. It was mainly due to the low quality of the sediments extracted from the pipeline ditch.

  17. De Minimis Thresholds for Federal Building Metering Appropriateness

    Henderson, Jordan W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-03-31

    The U.S. Department of Energy (DOE) is required by statute and Presidential Memorandum to establish guidelines for agencies to meter their Federal buildings for energy (electricity, natural gas, and steam) and water. See 42 U.S.C. § 8253(e). DOE issued guidance in February 2006 on the installation of electric meters in Federal buildings. A recent update to the 2006 guidance accounts for more current metering practices within the Federal Government. The updated metering guidance specifies that all Federal buildings shall be considered “appropriate” for energy or water metering unless identified for potential exclusion. In developing the updated guidance to carry out the statue, Congress also directed DOE to (among other things) establish exclusions from the metering requirements based on the de minimis quantity of energy use of a Federal building, industrial process, or structure. This paper discusses the method used to identify de minimis values.

  18. Study on installation of the submersible mixer

    Tian, F; Shi, W D; He, X H; Xu, Y H; Jiang, H

    2013-01-01

    Study on installation of the submersible mixer for sewage treatment has been limited. In this article, large-scale computational fluid dynamics software FLUENT6.3 was adopted. ICEM software was used to build an unstructured grid of sewage treatment pool. After that, the sewage treatment pool was numerically simulated by dynamic coordinate system technology and RNG k-ε turbulent model and PIOS algorithm. Agitation pools on four different installation location cases were simulated respectively, and the external characteristic of the submersible mixer and the velocity cloud of the axial section were respectively comparatively analyzed. The best stirring effect can be reached by the installation location of case C, which is near the bottom of the pool 600 mm and blade distance the bottom at least for 200 mm wide and wide edge and narrow edge distance by 4:3. The conclusion can guide the engineering practice

  19. Project installation the large equipment in line system in Brazil. Gas export line valve P-40 FPSO-MLS. Field Marlim Sul, Campos Basin, Brazil; Operacao de instalacao do maior equipamento no sistema in line ja realizado no Brasil. Valvula do gasoduto P-40 X FPSO-MLS. Campo de Marlim Sul, Bacia de Campos, Brasil

    Marques, Marcos Antonio Rodrigues; Fernandes, Paulo Tavares [PETROBRAS, Campos dos Goytacases, RJ (Brazil). Exploracao e Producao

    2005-07-01

    This work will approach the current level of development of the installation of connected underwater equipment to flexible lines in the underwater engineering operations in Campos' Basin. The project will show studies, analysis and simulations (through software developed by PETROBRAS) about the installation of the largest equipment laid in the 'in-line' system (connected to flexible lines) in Brazil - and one of the largest of the world: the ESDV (Emergency Shut Down Valve) of the gas pipeline P-40 x FPSO-MLS, in the South Marlim field, in Campos' Basin. This ESDV, of about 18.000 kg, 4 m height and 6,5 m length, has the purpose of assuring the safety conditions on the facilities, interrupting the gas flow exported for P-40 in case of emergency situations. Its installation opened a new alternative in releasing underwater equipment, using the ships that install the flexible lines. This operation occurred in June, 2004, and required the use of a second vessel for support and monitoring of the ESDV laying. The ESDV was installed at 400 m from FPSO-MLS, in a water depth of 1.137 m. This method shall be used broadly by the company in the implantation of the new units of Campos' Basin, and the upcoming studies must consider the gradual increase of the water depth in the new projects. This work will focus the technological development in this area, and one of its purposes is to foresee the future difficulties that can appear in the implantation of the production systems in deep and ultra-deep waters. (author)

  20. Nuclear Installations Act 1969

    1969-01-01

    The purpose of this Act is to amend the Nuclear Installations Act 1965 to bring it into full compliance with the international conventions on nuclear third party liability to which the United Kingdom is a Signatory, namely, the Paris Convention, the Brussels Supplementary Convention and the Vienna Convention. (NEA) [fr

  1. Installing and Scaling out Ubuntu Enterprise Cloud in Virtual Environment

    Pantić, Zoran; Ali Babar, Muhammad

    This document contains the supplemental material to the book “Guidelines for Building a Private Cloud Infrastructure”. This document provides guidance on how to install Ubuntu Enterprise Cloud in virtual environment, and afterwards how to scale out when needed. The purpose of this supplemental book...... is to provide a practical, step-by-step, detailed guide on how to dimension and install the machines and network. Some initial steps of configuring the cloud are also covered. The installation is performed in a virtual environment based on Windows 7 and VMware Workstation 7. The cloud installation is performed...... cloud, both using the command line tools, and GUI based tool HybridFox....

  2. Design/installation and structural integrity assessment under the Federal Facility Agreement for Bethel Valley low-level waste collection and transfer system upgrade for Building 2026 (High Radiation Level Analytical Laboratory) and Building 2099 (Monitoring and Control Station) at Oak Ridge National Laboratory

    1994-11-01

    This document presents a Design/Installation and Structural Integrity Assessment for a replacement tank system for portions of the Bethel Valley Low-Level Waste (LLW) System, located at the Oak Ridge Reservation, Oak Ridge, Tennessee. This issue of the assessment covers the design aspects of the replacement tank system, and certifies that the design has sufficient structural integrity and is acceptable for the storing or treating of hazardous and/or radioactive substances. This document will be reissued at a future date and will then include the assessment of the installation of the replacement tank system. The present issue identifies specific activities that must be completed during the fabrication, installation, and testing of the replacement tank system in order to provide assurance that the final installation complies with governing requirements

  3. Manure gas

    Carre, I

    1948-11-01

    Descriptions are given of several batch digesters: the Algerian, Salubra, Betur, Baudot-Hardoll and Ofla, and Somagaz designs. Sketches of two Ducellier and Isman designs are given with a photograph of an installation consisting of four contiguous, rectangular concrete tanks. There are short explanations of the fundamentals and economics of the process, and of the use of the gas.

  4. The latest electrical installation (I)

    Won, Jong Su

    1976-04-01

    This book deals with the latest electrical installation. The contents of this book are construction electrical installation, regulations related electrical installation, foundation and principle of wiring, main line feeder, lighting installation, power of wiring, main line feeder, lighting installation, power installation, method to read structure drawing for electrical construct drawing electric lamp wiring diagram, working drawing, material and tools and method of construction of electrical installation on types of wiring construction, metallic conduit, rigid poly-vinyl conduit wiring, bus duct work, cable work and insulation out of metal lathed.

  5. Inspection method as a tool for 'Bouwtransport'. Quality of building facade determines the functioning of installations; Ontwikkelde inspectiemethodiek Bouwtransport kan helpen. Kwaliteit gebouwschil bepaalt functioneren installaties

    Ten Bolscher, G.H. [DWA installatie- en energieadvies, Bodegraven (Netherlands)

    2012-02-15

    Buildings that have energy efficient or sustainable energy systems with low temperature heating have high demands when it comes to the constructional quality. Defects in the building facade often cause comfort complaints resulting from draught or cold radiation. To support local authorities and construction parties, the Dutch province of North Holland developed an inspection method: BouwTransparant. This instrument supports local authorities, environmental agencies and construction parties in realizing the EPC requirements. [Dutch] Gebouwen met energie-efficiente of duurzame energiesystemen met lage-temperatuurverwarming stellen hoge eisen aan de bouwkundige kwaliteit. Gebreken in de gebouwschil veroorzaken vaak comfortklachten door tocht of koudestraling. Om gemeenten en bouwende partijen te ondersteunen heeft de provincie Noord-Holland een inspectiemethodiek ontwikkeld: BouwTransparant. Dit is een instrument om gemeenten, milieudiensten en bouwende partijen te ondersteunen bij de realisatie van de EPC-eisen.

  6. Simulation of the build-up phase of a high voltage low pressure gas discharge using Monte-Carlo-methods

    Niessen, W.

    1990-02-01

    In this report the simulation of a Pseudospark predischarge between anode and cathode using Monte-Carlo-Methods is described. In the early phase of the discharge electric and magnetic self-fields can be neglected. The model is based on a discharge between two infinitely extended capacitor plates. Eleven different collision reactions and two electrode surface effects are taken into account. A Fortran program was developed that computes the built-up of the discharge in time and space. A specially of the code is, that not only electrons and ions are taken into account, but also fast neutral atoms and molecules. Three pairs of diode-length and voltage were investigated at different pressures: 350 kV/5.0 cm, 30 kV/10.0 cm and 6.9 kV/0.7 cm. The working gas was hydrogen. The computations included: The Paschen-curve, the time evolution of the current densities of the electrons at the anode and the ions at the cathode, the space- and time-dependent particle densities, the time-dependent energy distributions of the different particle species, the relative number of the different collision reactions. (orig./HSI) [de

  7. Worlds meet in Building 180.

    Raphael Vuillermet

    In the assembly hall of Building 180, several teams of various nationalities and different countries work together for the ATLAS forward muon detector. For nearly two years, Americans, Chinese, Europeans, Israelis, Japanese, Pakistanis and Russians are assembling and testing the so-called "Big Wheels" and the muon EIL4 stations. Each team is independent in its tasks: one team is assembling the mechanical structure, another one is installing services and muon chambers, while a third is testing the electronics and the gas system. A team is in charge of the transport and storage of the sectors and another is assembling the sectors in the ATLAS cavern. A total of nearly 60 people are participating in this project. Some members for the ATLAS Big Wheel team in the assembly hall of building 180. People from different cultures and religions and with different mother tongues are working side by side in harmony. Everyone in building 180, from technicians to professors, has the opportunity to meet and work with...

  8. Department of the Army Installation Restoration Program

    Anderson, A.W.

    1988-01-01

    The Army's Installation Restoration Program (IRP) was established in 1975 in response to regulatory action at several installations where past disposal practices had caused contamination of streams and groundwater. The need to decontaminate excess Army-owned real estate also was considered in early IRP activities. A variety of site types have been discovered on Army installations. The major site types evaluated to date include: contaminated soil areas, landfills, lagoons, buildings, burning grounds, sumps, pits, storage tanks, sewage treatment plants, storage pads, industrial wastewater treatment plants, and salvage yards. Twenty Army installations have been proposed for or listed on the National Priorities List (NPL). The need for taking action at hazardous waste sites, however, is based on threats they pose to human health, welfare or the environment. Sites do not have to be on the SPL in order to be cleaned up through IRP activities. All of the sites that caused Army installations to be proposed for the NPL are being evaluated and cleaned up. In addition, all Army properties have been or will be assessed and where needed they will be addressed by the IRP

  9. BROOKHAVEN: RHIC installation

    Anon.

    1994-01-01

    This summer, the first superconducting magnet was installed in 3.8 kilometre tunnel for Brookhaven's RHIC heavy ion collider (October, page 31). Manufactured by Northrop Grumman's Electronics and System Integration Division, the magnet is the first of RHIC's 373 dipoles. In addition to the dipoles, Northrop Grumman will also provide 432 RHIC quadrupoles. The first quadrupole was delivered on 8 April, a month before the first dipole arrived for onsite testing prior to installation. RHIC will need 1,700 superconducting magnets - dipoles, quadrupoles, sextupoles and correcting magnets, 1,200 of which will be built by industry and the rest built at Brookhaven. The 300 sextupoles are being supplied by Everson Electric

  10. Entropy and Digital Installation

    Susan Ballard

    2005-01-01

    Full Text Available This paper examines entropy as a process which introduces ideas of distributed materiality to digital installation. Beginning from an analysis of entropy as both force and probability measure within information theory and it’s extension in Ruldof Arnheim’s text ‘Entropy and Art” it develops an argument for the positive rather thannegative forces of entropy. The paper centres on a discussion of two recent works by New Zealand artists Ronnie van Hout (“On the Run”, Wellington City Gallery, NZ, 2004 and Alex Monteith (“Invisible Cities”, Physics Room Contemporary Art Space, Christchurch, NZ, 2004. Ballard suggests that entropy, rather than being a hindrance to understanding or a random chaotic force, discloses a necessary and material politics of noise present in digital installation.

  11. Installation Strategic Planning Guidebook

    2012-05-01

    Installation natural resource concerns (for example, wetlands , number of endangered species, water use restrictions, encroachment on training lands...Koehler Publishing, 1994 7. Strategy Safari – A Guided Tour Through the Wilds of Strategic Management by Henry Mintzberg, Bruce Ahlstrand, and...T. (1987). NY: Knopf 36. Shaping Strategic Planning: Frogs, Dragons, Bees and Turkey Tails. Pfeiffer, J. W., Goodstein, L. D. & Nolan, T. M. (1989

  12. Installing the ALICE detector

    Maximilien Brice

    2006-01-01

    The huge iron yoke in the cavern at Point 2 in the LHC tunnel is prepared for the installation of the ALICE experiment. The yoke is being reused from the previous L3 experiment that was located at the same point during the LEP project from 1989 to 2000. ALICE will be inserted piece by piece into the cradle where it will be used to study collisions between two beams of lead ions.

  13. SNRIU nuclear installation modifications

    Goroshanskyi, Andrii

    2013-01-01

    Design stages of Nuclear Instalations (NI): NI design is performed in three stages: • Feasibility study: - Feasibility study is developed on the basis of the customer task for production facilities and linear facilities engineering and transport infrastructure that require detailed study of relevant decisions and identify options for and feasibility of construction. • Design: - The design is developed on the basis of design task, initial data and approved the previous stage under three-stage design. • Detailed documentation

  14. Torsion instability of Dynamic Cables during Installation

    Opgård, Marie Finstad

    2017-01-01

    The oil and gas industry today is a heavily regulated segment, and current standard hasestablished restrictions which yields a very limited weather window for offshore cable installations. This is due to experience with cable failure in harsh weather. A limiting factor in current practice is the design criterion for the minimum allowable radius of curvature in the touchdown point. In addition, current practice does not allow for occurrence of compression in the touch down zone...

  15. Safety of nuclear installations

    1991-01-01

    In accordance with the Nuclear Energy Act, a Licence may only be issued if the precautions required by the state of the art have been taken to prevent damage resulting from the construction and operation of the installation. The maximum admissible body doses in the area around the installation which must be observed in planning constructional and other technical protective measures to counter accidents in or at a nuclear power station (accident planning values, are established). According to the Radiological Protection Ordinance the Licensing Authority can consider these precautions to have been taken if, in designing the installation against accidents, the applicant has assumed the accidents which, according to the Safety Criteria and Guidelines for Nuclear Power Stations published in the Federal Register by the Federal Minister of the Interior after hearing the competent senior state authorities, must determine the design of a nuclear power station. On the basis of previous experience from safety analysis, assessment and operation of nuclear power stations, the accident guidelines published here define which accidents are determinative for the safety-related design of PWR power stations and what verification -particularly with regard to compliance with the accident planning values of the Radiological Protection Ordinance -must be provided by the applicant. (author)

  16. First ALICE detectors installed!

    2006-01-01

    Detectors to track down penetrating muon particles are the first to be placed in their final position in the ALICE cavern. The Alice muon spectrometer: in the foreground the trigger chamber is positioned in front of the muon wall, with the dipole magnet in the background. After the impressive transport of its dipole magnet, ALICE has begun to fill the spectrometer with detectors. In mid-July, the ALICE muon spectrometer team achieved important milestones with the installation of the trigger and the tracking chambers of the muon spectrometer. They are the first detectors to be installed in their final position in the cavern. All of the eight half planes of the RPCs (resistive plate chambers) have been installed in their final position behind the muon filter. The role of the trigger detector is to select events containing a muon pair coming, for instance, from the decay of J/ or Y resonances. The selection is made on the transverse momentum of the two individual muons. The internal parts of the RPCs, made o...

  17. Gas centrifuge uranium enrichment programme in the United States of America

    Gestson, D.K.

    1983-01-01

    The technology of uranium enrichment using the gas centrifuge is fully proven as a result of over twenty years of research. The high performance of the centrifuge has been confirmed, and its reliability established, through detailed evaluation of a series of centrifuge designs. The baseline centrifuge for the Gas Centrifuge Enrichment Plant (GCEP) is now in commercial production by three qualified manufacturers. It will be ready for installation in GCEP on schedule. The GCEP construction is also on schedule, with two process buildings expected to start operation in 1988 and 1989. Development and demonstration of the Set IV advanced gas centrifuge is under way and it is expected to be ready for installation in Process Building 3 in early 1989. (author)

  18. Heat Flow and Gas Hydrates on the Continental Margin of India: Building on Results from NGHP Expedition 01

    Anne Trehu; Peter Kannberg

    2011-06-30

    The Indian National Gas Hydrate Program (NGHP) Expedition 01 presented the unique opportunity to constrain regional heat flow derived from seismic observations by using drilling data in three regions on the continental margin of India. The seismic bottom simulating reflection (BSR) is a well-documented feature in hydrate bearing sediments, and can serve as a proxy for apparent heat flow if data are available to estimate acoustic velocity and density in water and sediments, thermal conductivity, and seafloor temperature. Direct observations of temperature at depth and physical properties of the sediment obtained from drilling can be used to calibrate the seismic observations, decreasing the uncertainty of the seismically-derived estimates. Anomalies in apparent heat flow can result from a variety of sources, including sedimentation, erosion, topographic refraction and fluid flow. We constructed apparent heat flow maps for portions of the Krishna-Godavari (K-G) basin, the Mahanadi basin, and the Andaman basin and modeled anomalies using 1-D conductive thermal models. Apparent heat flow values in the Krishna-Godavari (K-G) basin and Mahanadi basin are generally 0.035 to 0.055 watts per square meter (W/m{sup 2}). The borehole data show an increase in apparent heat flow as water depth increases from 900 to 1500 m. In the SW part of the seismic grid, 1D modeling of the effect of sedimentation on heat flow shows that {approx}50% of the observed increase in apparent heat flow with increasing water depth can be attributed to trapping of sediments behind a 'toe-thrust' ridge that is forming along the seaward edge of a thick, rapidly accumulating deltaic sediment pile. The remainder of the anomaly can be explained either by a decrease in thermal conductivity of the sediments filling the slope basin or by lateral advection of heat through fluid flow along stratigraphic horizons within the basin and through flexural faults in the crest of the anticline. Such flow

  19. Heat Flow and Gas Hydrates on the Continental Margin of India: Building on Results from NGHP Expedition 01

    Trehu, Anne; Kannberg, Peter

    2011-06-30

    The Indian National Gas Hydrate Program (NGHP) Expedition 01 presented the unique opportunity to constrain regional heat flow derived from seismic observations by using drilling data in three regions on the continental margin of India. The seismic bottom simulating reflection (BSR) is a well-documented feature in hydrate bearing sediments, and can serve as a proxy for apparent heat flow if data are available to estimate acoustic velocity and density in water and sediments, thermal conductivity, and seafloor temperature. Direct observations of temperature at depth and physical properties of the sediment obtained from drilling can be used to calibrate the seismic observations, decreasing the uncertainty of the seismically-derived estimates. Anomalies in apparent heat flow can result from a variety of sources, including sedimentation, erosion, topographic refraction and fluid flow. We constructed apparent heat flow maps for portions of the Krishna-Godavari (K-G) basin, the Mahanadi basin, and the Andaman basin and modeled anomalies using 1-D conductive thermal models. Apparent heat flow values in the Krishna-Godavari (K-G) basin and Mahanadi basin are generally 0.035 to 0.055 watts per square meter (W/m2). The borehole data show an increase in apparent heat flow as water depth increases from 900 to 1500 m. In the SW part of the seismic grid, 1D modeling of the effect of sedimentation on heat flow shows that ~50% of the observed increase in apparent heat flow with increasing water depth can be attributed to trapping of sediments behind a "toe-thrust" ridge that is forming along the seaward edge of a thick, rapidly accumulating deltaic sediment pile. The remainder of the anomaly can be explained either by a decrease in thermal conductivity of the sediments filling the slope basin or by lateral advection of heat through fluid flow along stratigraphic horizons within the basin and through flexural faults in the crest of the anticline. Such flow probably plays a role in

  20. SOL-PAC: Integrated solar heating and heat pump systems for refurbished buildings - Performance analysis; SOL-PAC: analyse des performances du couplage d'une pompe a chaleur avec une installation solaire thermique pour la renovation - Rapport final

    Citherlet, C.; Bony, J.; Nguyen, B.

    2008-07-01

    The purpose of this study is to evaluate the energetic and economic performances of various types of brine/water heat pumps coupled with a fan coil fitted with solar collectors. Different indicators such as the annual coefficient of performance or the electricity consumption have been compared between the different analysed systems. The optimization of the energy control system and energy storage was investigated in order to reduce the operation time of the fan coil. This study has been performed using the TRNSYS computerized simulation package. The icing of the fan coil as well as its defrosting cycles could not been taken into account within the framework of this project, because of a lack of a numerical model. At current electricity prices, the most economical solution remains the heat pump without solar collectors. However, from an energy point of view, the annual overall coefficient of performance of the installation may be improved by 15 to 36%, depending on the climate, thanks to the coupling with solar collectors. (author)

  1. Deployment Considerations for Low-cost Air Quality Sensor Networks; Examining Spatial Variability of Gas-Phase Pollutants Around a Building in Los Angeles

    Collier-Oxandale, A. M.; Hannigan, M.; Casey, J. G.; Johnston, J.; Coffey, E.; Thorson, J.

    2017-12-01

    The field of low-cost air quality sensing technologies is growing rapidly through the continual development of new sensors, increased research into sensor performance, and more and more community groups utilizing sensors to investigate local issues. However, as this technology is still in an exploratory phase, there are few `best-practices' available to serve as guidelines for these projects and the standardization of some procedures could benefit the research community as a whole. For example, deployment considerations such as where and how to place a monitor at a given location are often determined by accessibility and safety, power-requirements, and what is an ideal for sampling the target pollutant. Using data from multiple gas-phase sensors, we will examine the importance of siting considerations for low-cost monitoring systems. During a sampling campaign in Los Angeles, a subset of monitors was deployed at one field site to explore the variability in air quality sensor data around a single building. The site is a three story, multi-family housing unit in a primarily residential neighborhood that is near two major roadways and other potential sources of pollution. Five low-cost monitors were co-located prior to and following the field deployment. During the approximately 2.5-month deployment, these monitors were placed at various heights above street level, on different sides of the building, and on the roof. In our analysis, we will examine how monitor placement affects a sensor's ability to detect local verses more regional trends and how this building-scale spatial variability changes over time. Additionally, examining data from VOC sensors (quantified for methane and total non-methane hydrocarbon signals) and O3 sensors will allow us to compare the variability of primary and secondary pollutants. An outcome of this analysis may include guidelines or `best practices' for siting sensors that could aid in ensuring the collection of high quality field data

  2. Samus Toroid Installation Fixture

    Stredde, H.; /Fermilab

    1990-06-27

    The SAMUS (Small Angle Muon System) toroids have been designed and fabricated in the USSR and delivered to D0 ready for installation into the D0 detector. These toroids will be installed into the aperture of the EF's (End Toroids). The aperture in the EF's is 72-inch vertically and 66-inch horizontally. The Samus toroid is 70-inch vertically by 64-inch horizontally by 66-inch long and weighs approximately 38 tons. The Samus toroid has a 20-inch by 20-inch aperture in the center and it is through this aperture that the lift fixture must fit. The toroid must be 'threaded' through the EF aperture. Further, the Samus toroid coils are wound about the vertical portion of the aperture and thus limit the area where a lift fixture can make contact and not damage the coils. The fixture is designed to lift along a surface adjacent to the coils, but with clearance to the coil and with contact to the upper steel block of the toroid. The lift and installation will be done with the 50 ton crane at DO. The fixture was tested by lifting the Samus Toroid 2-inch off the floor and holding the weight for 10 minutes. Deflection was as predicted by the design calculations. Enclosed are sketches of the fixture and it relation to both Toroids (Samus and EF), along with hand calculations and an Finite Element Analysis. The PEA work was done by Kay Weber of the Accelerator Engineering Department.

  3. Nuclear reactor installation

    Keller, W.

    1976-01-01

    A nuclear reactor installation includes a pressurized-water coolant reactor vessel and a concrete biological shield surrounding this vessel. The shield forms a space between it and the vessel large enough to permit rapid escape of the pressurized-water coolant therefrom in the event the vessel ruptures. Struts extend radially between the vessel and shield for a distance permitting normal radial thermal movement of the vessel, while containing the vessel in the event it ruptures, the struts being interspaced from each other to permit rapid escape of the pressurized-water coolant from the space between the shield and the vessel

  4. Decommissioning nuclear installations

    Dadoumont, J.

    2010-01-01

    When a nuclear installation is permanently shut down, it is crucial to completely dismantle and decontaminate it on account of radiological safety. The expertise that SCK-CEN has built up in the decommissioning operation of its own BR3 reactor is now available nationally and internationally. Last year SCK-CEN played an important role in the newly started dismantling and decontamination of the MOX plant (Mixed Oxide) of Belgonucleaire in Dessel, and the decommissioning of the university research reactor Thetis in Ghent.

  5. Fires of sodium installations

    Hajek, L.; Tlalka, R.

    1984-01-01

    A survey is presented of the literature dealing with fires of sodium installations between 1974 and 1981. Also described are three experimental fires of ca 50 kg of sodium in an open area, monitored by UJV Rez. The experimental conditions of the experiments are described and a phenomenological description is presented of the course of the fires. The experiments showed a relationship between wind velocity in the area surrounding the fire and surface temperature of the sodium flame. Systems analysis methods were applied to sodium area, spray and tube fires. (author)

  6. Worldwide installed geothermal power

    Laplaige, P.

    1995-01-01

    Worldwide electric energy production data are easy to compile, according to the informations given by individual countries. On the contrary, thermal applications of geothermics are difficult to quantify due to the variety of applications and the number of countries concerned. Exhaustive informations sometimes cannot be obtained from huge countries (China, Russia..) because of data centralization problems or not exploitable data transmission. Therefore, installed power data for geothermal heat production are given for 26 countries over the 57 that have answered the International Geothermal Association questionnaire. (J.S.). 1 fig., 2 tabs., 1 photo

  7. Wireless installation standard

    Lim, Hwang Bin

    2007-12-01

    This is divided six parts which are radio regulation law on securing of radio resource, use of radio resource, protection of radio resource, radio regulation enforcement ordinance with securing, distribution and assignment of radio regulation, radio regulation enforcement regulation on utility of radio resource and technical qualification examination, a wireless installation regulation of technique standard and safety facility standard, radio regulation such as certification regulation of information communicative machines and regulation of radio station on compliance of signal security, radio equipment in radio station, standard frequency station and emergency communication.

  8. Nuclear installations sites safety

    Barber, P.; Candes, P.; Duclos, P.; Doumenc, A.; Faure, J.; Hugon, J.; Mohammadioun, B.

    1988-11-01

    This report is divided into ten parts bearing: 1 Safety analysis procedures for Basis Nuclear Installations sites (BNI) in France 2 Site safety for BNI in France 3 Industrial and transport activities risks for BNI in France 4 Demographic characteristics near BNI sites in France 5 Meteorologic characteristics of BNI sites in France 6 Geological aspects near the BNI sites in France 7 Seismic studies for BNI sites in France 8 Hydrogeological aspects near BNI sites in France 9 Hydrological aspects near BNI sites in France 10 Ecological and radioecological studies of BNI sites in France [fr

  9. Performance of buried pipe installation.

    2010-05-01

    The purpose of this study is to determine the effects of geometric and mechanical parameters : characterizing the soil structure interaction developed in a buried pipe installation located under : roads/highways. The drainage pipes or culverts instal...

  10. Emergency gas processing device

    Taruishi, Yoshiaki; Sasaki, Susumu.

    1984-01-01

    Purpose: To enable the reduction of radioactive substances released out of reactor buildings irrespective of the aging change in the buildings. Constitution: There are provided an exhaust gas flow channel for cleaning contaminated airs within a reactor building by way of a series of filters and exhausting the cleaned airs by means of exhaust fans to the outside and a gas recycling flow channel having a cooler in connection with the exhaust gas flow channel at a position downstream of the exhaust fans for returning the cleaned airs in the exhaust gas flow channel to the inside of the reactor buildings. The pressure difference between the outside and the inside of the reactor buildings is made constant by controlling the air flow channel within the gas recycling flow channel by a flow control valve. The airs cleaned by the series of the filters are recycled to the inside of the buildings to decrease the radioactive substance within the buildings. (Horiuchi, T.)

  11. New technological developments in gas processing

    Draper, R.C.

    1996-01-01

    The changes that the natural gas industry has undergone over the last few years was discussed. Low natural gas prices forced companies to react to their high reserves replacements costs. They were forced to downsize and undergo major restructuring because they were losing money due to high operating costs; the future for natural gas prices looked pessimistic. The changes have led to a new kind of business practice, namely 'partnering with third party processor', mid-stream companies known as aggregators, to build and operate facilities as part of a move towards cost effective improvements for gas producers. Besides reducing capital and operating costs, the producer under this arrangements can dedicate his capital to finding new gas which is the basis of growth. Recent technological changes in the gas processing industry were also touched upon. These included enhanced technologies such as increased liquid hydrocarbon recovery, segregation of C3+ and C5+, installation of gas separation membrane systems, small sulphur plants, acid gas injection and selective or mixed solvents. Details of some of these technologies were described. 2 refs., 2 figs

  12. CNGS Reflector installed

    2006-01-01

    A major component that will help target the CNGS neutrino beam for its 732km journey through the earth's crust, from CERN to the Gran Sasso laboratory in Italy, has been installed in its final position. The transport of the huge magnetic horn reflector through the CNGS access gallery. A team from CNGS and TS/IC, and the contractors DBS, transported the magnetic horn reflector on 5th December, in a carefully conducted operation that took just under two hours. The reflector is 7m long, 1.6m in diameter and 1.6 tonnes in weight. With only a matter of centimetres to spare on either side, the reflector was transported through the CNGS access gallery, before being installed in the experiment's target chamber. The larger of two magnetic horns, the reflector will help refocus sprays of high energy pions and kaons emitted after a 0.5MW stream of protons from the Super Proton Synchrotron (SPS) strikes nucleons in a graphite target. The horns are toroidal magnetic lenses and work with high pulsed currents: 150 kA f...

  13. Heating equipment installation system

    Meuschke, R.E.; Pomaibo, P.P.

    1991-01-01

    Disclosed is a method for installing a heater unit assembly in a reactor pressure vessel for performance of an annealing treatment on the vessel, the vessel having a vertical axis, being open at the top, being provided at the top with a flange having a horizontal surface, and being provided internally, at a location below the flange, with orientation elements which are asymmetrical with respect to the vertical axis, by the steps of: providing an orientation fixture having an upwardly extending guide member and orientation elements and installing the orientation fixture in the vessel so that the orientation elements of the orientation fixture mate with the orientation elements of the pressure vessel in order to establish a defined position of the orientation fixture in the pressure vessel, and so that the guide member projects above the pressure vessel flange; placing a seal ring in a defined position on the pressure vessel flange with the aid of the guide member; mounting at least one vertical, upwardly extending guide stud upon the seal ring; withdrawing the orientation fixture from the pressure vessel; and moving the heater unit assembly vertically downwardly into the pressure vessel while guiding the heater unit assembly along a path with the aid of the guide stud. 5 figures

  14. State-of-the-art of NORM nuclide determination in samples from oil and gas production : Validation of potential standardization methods through an interlaboratory test programme

    Knaepen, WAI; Bergwerf, W; Lancee, PJF; vanDijk, W; Jansen, JFW; Janssen, RGC; Kiezenberg, WHT; vanSluijs, R; Tijsmans, MH; Voors, PI

    1995-01-01

    Gas and oil companies frequently encounter build-up of Naturally Occurring Radioactive Material (NORM) in their production and processing facilities. In the Netherlands NORM is subject to strict national regulations and, consequently, installations have to be screened on a regular basis. The

  15. Natural gas, the comfort stamina; Le gaz nerf du confort

    Le Bail, L. [Gaz de France (GDF), 75 - Paris (France)

    1997-09-01

    According to consumers and thermal engineers opinion, natural gas is the most performing and the less expensive energy source for domestic uses. In this optimistic context, the customers expectations for more performing, economical and aesthetic appliances and systems is growing up. This paper gives a general overview of the recent improvements of natural gas heating systems and appliances: high efficiency heating plants, mural and airtight central heating plants, condensation heating plants, heaters, mono- or dual-pipe heating installations, heating floors etc.. All these products have a significant effect on the thermal comfort of residential buildings and on the reduction of energy costs. (J.S.)

  16. ID Barrel installed in cryostat

    Apsimon, R.; Romaniouk, A.

    Wednesday 23rd August was a memorable day for the Inner Detector community as they witnessed the transport and installation of the central part of the inner detector (ID-barrel) into the ATLAS detector. Many members of the collaboration gathered to witness this moment at Point 1. After years of design, construction and commissioning, the outer two detectors (TRT and SCT) of the ID barrel were moved from the SR1 cleanroom to the ATLAS cavern. The barrel was moved across the car park from building 2175 to SX1. Although only a journey of about 100 metres, this required weeks of planning and some degree of luck as far as the weather was concerned. Accelerometers were fitted to the barrel to provide real-time monitoring and no values greater than 0.1 g were recorded, fully satisfying the transport specification for this extremely precise and fragile detector. Muriel, despite her fear of heights, bravely volunteered to keep a close eye on the detector. Swapping cranes to cross the entire parking lot, while Mur...

  17. Design/Installation and Structural Integrity Assessment of the Bethel Valley Low-Level Waste Collection and Transfer System Upgrade for Building 3544 (Process Waste Treatment Plant) at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    1996-12-01

    This document describes and assesses planned modifications to be made to the Building 3544 Process Waste Treatment Plant of the Oak Ridge National Laboratory, Oak Ridge, Tennessee. The modifications are made in response to the requirements of the Federal Facility Agreement (FFA) relating to environmental protection requirements for tank systems. The modifications include the provision of a new double contained LLW line replacing an existing buried line that does not provide double containment. This new above ground, double contained pipeline is provided to permit discharge of treated process waste fluid to an outside truck loading station. The new double contained discharge line is provided with leak detection and provisions to remove accumulated liquid. An existing LLW transfer pump, concentrated waste tank, piping and accessories are being utilized, with the addition of a secondary containment system comprised of a dike, a chemically resistant internal coating on the diked area surfaces and operator surveillance on a daily basis for the diked area leak detection. This assessment concludes that the planned modifications comply with applicable requirements of Federal Facility Agreement, Docket No. 89-04-FF, covering the Oak Ridge Reservation

  18. Decommissioning and abandonment of offshore installations

    Side, J.C.

    1992-01-01

    To the onlooker surprising little thought was given at the project planning stage to the fate of offshore facilities once their production lifetimes had come to an end. Throughout the 1970s at least, international law required the complete removal of all structures and installations one disused or abandoned. Fishermen's organisations were led to believe that such installations would be entirely removed yet many of the designs of these show that removal was not much in the minds of the engineers or project management during the design stages. Changes in the text of the United Nations' Convention on the Law of the Sea and (by their widespread legal adoption) in customary international law may now permit partial removal of installations subject to important safeguards for navigation, the environment and other users of the sea. Of the North Sea states at least one has adopted policies that will minimise the cost associated with offshore decommissioning and abandonment and both the UK and Norway are adopting legislation which will provide for a case by case approach to the decommissioning and abandonment of offshore facilities and allow partial removal options. There has thus been a recent and significant change in approach to the abandonment of offshore oil and gas installations. This chapter reviews the development of abandonment laws and policies, outlines the available removal options, and provides a consideration of the environmental and fishery implications of these for the North Sea. (Author)

  19. Applications of the automatic meter reading techniques at the Brazilian gas domestic market; Application des techniques de releve automatique des compteurs sur le marche domestique Bresilien du gaz

    Venancio, J.; Monteiro, F. [Comgas, Sao Paulo (Brazil); D' Oliveira, R.D. [ORBIS, Curitiba (Brazil)

    2000-07-01

    This article will describe applications of the automation and automatic meter reading techniques at the internal gas pipes installations design, considering residential and commercial buildings, and taking in account the tendency of rapid growth of the activities related to the natural gas industry in Brazil, as well as the recently development of new technologies that can be applied with affordable prices. It will be analysed the application of an automatic meter reading technology in a building of several floors in Sao Paulo, which gas installations design is being carried up, with be purpose of making a comparative cost-effectiveness study with the traditional constructive methods applied in Brazil. As a result, it will be purposed a new commercialization model for the gas in Brazil at the residential and commercial market. (authors)

  20. Installing Ubuntu Enterprise Cloud in a Physical Environment

    Pantić, Zoran; Ali Babar, Muhammad

    This document contains the supplemental material to “Guidelines for Building a Private Cloud Infrastructure.” This supplemental material provides guidance on how to install Ubuntu Enterprise Cloud in a physical environment. The purpose of this document is to provide a practical, step......-by-step, detailed guide on how to pre-configure and install the machines and network. For more detailed description of the steps, a reader is advised to refer to another supplemental book named “Installing and Scaling out Ubuntu Enterprise Cloud in Virtual Environment.” There are a few more details, accompanied...... with screenshots. The material included in this supplemental document is based on the installation that was performed in a physical environment based on HP ProLiant DL380 G4 servers, 100 Mbit/s witches, and a firewall/router that isolated the whole solution. The cloud installation was performed using the (for...

  1. The tariffs of use of liquefied natural gas transportation networks and facilities; Les tarifs d'utilisation des reseaux de transport et des installations de gaz naturel liquefie

    NONE

    2005-07-01

    The new tariff proposals for the use of natural gas transportation networks were transmitted to the French Ministry of economy, finances and industry on October 27, 2004 by the commission of energy regulation. These proposals have been adopted and are the object of three legislative texts: the decree no. 2005-607 from May 27 2005 relative to the tariffing rules, the by-law from May 27, 2005 relative to the definition of balancing areas, and the advice from May 27, 2005 relative to the tariffs of use of natural gas transportation networks. In application of article 7 of the law from January 3, 2003, the implementation of the first tariffs of use of natural gas transportation networks and of liquefied natural gas (LNG) facilities is defined in the decree no. 2004-994 from September 21, 2004. On the main transportation network, the tariffing is of 'input-output' type and does not depend on the distance, while at the regional network scale, the tariffing is linked with the distance. The tariff of use of LNG facilities is the sum of 4 terms: a fixed term applied to each batch unloaded at the methane terminal, a term proportional to the unloaded LNG quantities, a term depending on the duration of use of LNG storage facilities and a term covering the gas consumptions of LNG facilities. This document gathers these different legislative texts with their appendixes. (J.S.)

  2. SOME SPECIFIC FEATURES OF ENERGY CONSUMPTION IN MODERN RESIDENTIAL BUILDINGS

    S. N. Osipov

    2018-01-01

    Full Text Available Over the past 20 years there have been significant changes in the customer requirements for housing in the countries of the former USSR. Besides, new materials and construction products, such as the ones for sealed windows and balcony doors have appeared in the market. The number of vacant flats with the heating off in the winter significantly increased that may cause condensation on the surfaces of interroom partitions and the formation of mold. Meanwhile, the requirements for lower energy consumption are constantly increasing, that is especially pronouncedly manifested in the growth of normative values of thermal resistance of enclosing structures of buildings and in the increased interest in the use of secondary energy resources extracted from the air and effluent wastewater. The present article describes the method to prevent moisture condensation on the fencing of adjacent premises with different temperatures containing heating systems and the use of waste heat removed from the room exhaust air. For quick emergency switching of in-house systems of heat and gas supply to outdoor mobile sources of heat and gas it is recommended to install special taps with connectors insulated in special niches in the walls or other parts of buildings considering the possibility of placing them close to the outer mobile sources of heat and gas. In the case of heating the building with the aid of a roof gas boiler or by doorto-door heaters fueled by gas, a single pipeline (collector, equipped with an additional device for the connection of emergency gas supply is being put along the wall. In order to reduce specific heat consumption for heating of buildings it is recommended to increase the net enclosure volume of buildings and to improve their form in various ways, including by combining two or more adjacent low-rise buildings in one secondary building with increasing height and with the broadening of either or each side for modernization and reconstruction

  3. An application of the gas-fired chilling and heating units to domestic houses

    Choi, J.H.; Yang, Y.M.; Chae, J.M.; Bang, H.S.; Kwon, O.B.; Yoo, S.I.; Kim, T.H. [R and D Center, Korea Gas Co. (Korea); Lee, T.W.; Kim, T.H.; Kim, B.H.; Hwang, I.J.; Kim, J.Y.; Kim, C.D.; Park, S.J. [Korea Institute of Construction Technology (Korea)

    1999-10-01

    Following researches and considerations were performed in this study for an efficient application of gas-fired chilling and heating units to the residential buildings. (1) Status of domestic cooling and heating for residential building. (2) Various introduction schemes of outdoor unit. (3) Design exclusive area for the gas appliance and installation of it. (4) Ventilation of exhaust gas and heat. (5) Prepare the installation specifications or standards for gas-fired chilling and heating units. (6) Design technique of plumbing for cooling and heating. (7) Evaluation of unit's capacity considering the thermal load of domestic buildings. (8) Cooling and heating system with the unit. (9) Fundamental test for evaluation of applicability. (10) Actual design and construction of experimental house for an application and a demonstration of the developed gas units. (11) Field test for cooling and heating. (12) Evaluation of economic efficiency. (13) Establish a business potential. (14) Establishment of legal and systematic support, energy rate. (15) Troubleshooting in the course of development and application of the new gas appliance. 41 refs., 214 figs., 52 tabs.

  4. Photovoltaics for professionals solar electric systems marketing, design and installation

    Falk, Antony; Remmers, Karl-Heinz

    2007-01-01

    For the building industry, the installation of photovoltaic systems has become a new field of activity. Interest in solar energy is growing and future business prospects are excellent. Photovoltaics for Professionals describes the practicalities of marketing, designing and installing photovoltaic systems, both grid-tied and stand-alone. It has been written for electricians, technicians, builders, architects and building engineers who want to get involved in this expanding industry. It answers all the beginner's questions as well as serving as a textbook and work of reference

  5. Gas transfer system

    Oberlin, J.C.; Frick, G.; Kempfer, C.; North, C.

    1988-09-01

    The state of work on the Vivitron gas transfer system and the system functions are summarized. The system has to: evacuate the Vivitron reservoir; transfer gas from storage tanks to the Vivitron; recirculate gas during operation; transfer gas from the Vivitron to storage tanks; and assure air input. The system is now being installed. Leak alarms are given by SF6 detectors, which set off a system of forced ventilation. Another system continuously monitors the amount of SF6 in the tanks [fr

  6. Demonstrate Energy Component of the Installation Master Plan Using Net Zero Installation Virtual Testbed

    2015-09-01

    compliant GIS, usually obtained from the installation itself. NZP also includes an appropriate weather file for the location selected, using the closest...such as solar photovoltaics, solar-thermal, wind energy, biomass (wood chips, etc.), biogas , or synthetic gas need to be considered as part of the mix...have better information. In some cases, such as photovoltaics, users can obtain data from an online system and enter it into NZP. In this case, users

  7. Gas engine supplied with fermentation gas

    Cupial, K

    1978-01-01

    A CH/sub 4/-rich fermentation gas from the waste-treatment plant at Czestochowa is used as fuel to drive the generating set composed of an electric generator and a piston diesel engine adapted to operation with the fermentation gas. The adaption involved the use of a classical car ignition installation instead of the injection pumps and injector. The gas contains approximately CH/sub 4/ 60, CO/sub 2/ 32, N 5, and H 3 volume%.

  8. Lietojumprogrammu instalāciju izveides risinājumi

    Zālītis, Mārtiņš

    2010-01-01

    Bakalaura darbā „Lietojumprogrammu instalāciju izveides risinājumi” mērķis ir izanalizēt lietotājam draudzīgas un nedraudzīgas instalācijas, kā arī salīdzināt instalāciju veidošanas rīkus, norādot uz to stiprajām un vājajām pusēm. Lai izpētītu instalāciju izveides iespējas tiek izmantota tīmeklī pieejamā informācija, autora darbs ar instalāciju rīkiem un to novērtējums. Parādīta sarežģītas instalācijas uzbūve, kas izveidota ar NSIS instalāciju rīku, kuru arī autors atzīst par labāko risinājum...

  9. Nuclear reactor installation

    Jungmann, A.

    1976-01-01

    A nuclear reactor metal pressure vessel is surrounded by a concrete wall forming an annular space around the vessel. Thermal insulation is in this space and surrounds the vessel, and a coolant-conductive layer is also in this space surrounding the thermal insulation, coolant forced through this layer reducing the thermal stress on the concrete wall. The coolant-conductive layer is formed by concrete blocks laid together and having coolant passages, these blocks being small enough individually to permit them to be cast from concrete at the reactor installation, the thermal insulation being formed by much larger sheet-metal clad concrete segments. Mortar is injected between the interfaces of the coolant-conductive layer and concrete wall and the interfaces between the fluid-conductive layer and the insulation, a layer of slippery sheet material being interposed between the insulation and the mortar. When the pressure vessel is thermally expanded by reactor operation, the annular space between it and the concrete wall is completely filled by these components so that zero-excursion rupture safeguard is provided for the vessel. 4 claims, 1 figure

  10. ROS Installation and Commissioning

    Gorini, B

    The ATLAS Readout group (a sub-group of TDAQ) has now completed the installation and commissioning of all of the Readout System (ROS) units. Event data from ATLAS is initially handled by detector specific hardware and software, but following a Level 1 Accept the data passes from the detector specific Readout Drivers (RODs) to the ROS, the first stage of the central ATLAS DAQ. Within the final ATLAS TDAQ system the ROS stores the data and on request makes it available to the Level 2 Trigger (L2) processors and to the Event Builder (EB) as required. The ROS is implemented as a large number of PCs housing custom built cards (ROBINs) and running custom multi-threaded software. Each ROBIN card (shown below) contains buffer memories to store the data, plus a field programmable gate array ( FPGA ) and an embedded PowerPC processor for management of the memories and data requests, and is implemented as a 64-bit 66 MHz PCI card. Both the software and the ROBIN cards have been designed and developed by the Readout g...

  11. Burnable gas concentration control device

    Goto, Hiroshi; Sanada, Takahiro; Kuboniwa, Takao.

    1980-01-01

    Purpose: To provide connecting ports by doubling nitrogen gas injection pipes thereby to secure lengthiness of the device only by providing one nitrogen gas generator. Constitution: Nitrogen gas injection pipes are provided in two lines separately, and attachable and detachable connecting ports for feeding nitrogen gas connectable to a movable type nitrogen gas supply installation for the purpose of backing up the nitrogen gas generator. (Yoshihara, H.)

  12. New fast reactor installation concept

    Anon.

    1976-01-01

    The large size and complexity of fast reactor installations are emphasised and these difficulties will be increased with the advent of fast reactors of higher power. In this connection a new concept of fast reactor installation is described with a view to reducing the size of the installation and enabling most components, including even the primary vessel, to be constructed within the confines of a workshop. Full constructional details are given. (U.K.)

  13. Installing Python Modules with pip

    Fred Gibbs

    2013-01-01

    This lesson shows you how to download and install Python modules. There are many ways to install external modules, but for the purposes of this lesson, we’re going to use a program called pip. As of Python 2.7.9 and newer, pip is installed by default. This tutorial will be helpful for anyone using older versions of Python (which are still quite common).

  14. Energy Requirement and Comfort of Gas- and Electric-powered Hot-water Systems

    Luedemann, B.; Schmitz, G.

    1999-01-01

    In view of the continuous reduction in the specific heating energy demand of new buildings the power demand for hot-water supply increasingly dominates the heating supply of residential buildings. Furthermore, the German energy-savings-regulation 2000 (ESVO) is intended to evaluate the techniques installed such as domestic heating or hot-water supply within an overall energetic view of the building. Planning advice for domestic heating, ventilation and hot-water systems in gas-heated, low-energy buildings has therefore been developed in a common research project of the Technical University of Hamburg Harburg (TUHH) and four energy supply companies. In this article different gas-or electricity-based hot-water systems in one family houses and multiple family houses are compared with one another with regard to the aspects of comfort and power requirements considering the user's behaviour. (author)

  15. Skaha Lake crossing, innovations in pipeline installation

    Fernandez, M.L.; Bryce, P.W.; Smith, J.D.

    1995-01-01

    This paper describes the construction of a 10.8 km long NPS16 (406 mm, 16 inch diameter) pipeline, across Skaha Lake, in the south Okanagan valley, British Columbia, Canada. The water crossing is part of the 32 km South Okanagan Natural Gas Pipeline Project (SONG) operated by BC Gas. The pipeline is located in a region dependent on year-round tourism. Therefore, the design and construction was influenced by sensitive environmental and land use concerns. From earlier studies, BC Gas identified surface tow or lay as preferred installation methods. The contractor, Fraser River Pile and Dredge departed from a conventional laybarge methodology after evaluating environmental data and assessing locally available equipment. The contractor proposed a surface tow with multiple surface tie-ins. This approach modification to the ''Surface Tow and Buoy Release Method'' (STBRM) used previously with success on relatively short underwater pipelines. A total of 10 pipe strings, up to 1 km long, were towed into position on the lake and tied-in using a floating platform. The joined pipeline was lowered to the lakebed by divers releasing buoys while tension was maintained from a winch barge at the free end of the pipeline. From analysis and field verified measurement the installation stresses were well below the allowable limits during all phases of construction. The entire construction, including mobilization and demobilization, lasted less than three months, and actual pipelaying less than three weeks. Installation was completed within budget and on schedule, without any environmental or safety related incidents. The SONG pipeline became operational in December 1994

  16. Patterns identification in supervisory systems of nuclear reactors installations and gas pipelines systems using self-organizing maps; Identificacao de padroes em sistemas supervisorios de instalacoes de reatores nucleares e em sistemas de gasodutos utilizando mapas auto-organizaveis

    Doraskevicius Junior, Waldemar

    2005-07-01

    Self-Organizing Maps, SOM, of Kohonen were studied, implemented and tested with the aim of developing, for the energy branch, an effective tool especially for transient identification in nuclear reactors and for gas pipelines networks logistic supervision, by classifying operations and identifying transients or abnormalities. The digital system for the test was developed in Java platform, for the portability and scalability, and for belonging to free development platforms. The system, executed in personal computers, showed satisfactory results to aid in decision taking, by classifying IRIS (International Reactor Innovative and Secure) reactor operation conditions (data from simulator) and by classifying Southeast (owner: TRANSPETRO - Brazil) gas pipeline network. Various adaptations were needed for such business, as new topologies for the output layer of artificial neural network and particular preparation for the input data. (author)

  17. Deliberation Nr 2017-047. Deliberation of the Commission for regulation of energy on the 16 March 2017 bearing opinion on the decree project defining purchase conditions for the electricity produced by installations mounted on building and using photovoltaic solar energy, with a peak power less than or equal to 100 kilowatts such as those defined in the 3. of the article D. 314-15 of the Code of Energy, and located in continental metropolitan France

    Carenco, Jean-Francois; Chauvet, Christine; Edwige, Catherine; Gassin, Helene; Padova, Yann; Sotura, Jean-Pierre

    2017-01-01

    After a brief presentation of the context, of the referral, and of the CRE (commission for the regulation of energy) ability, this document proposes an overview of the decree project in terms of concerned installations, and of payment conditions. These conditions are addressed in terms of levels, of evolution, of premium in relationship with integration to the building, of tariff indexing. The next part proposes a profitability analysis. It addresses various calculation hypotheses used to model business plans (total sale, installations for self-consumption), and analyses initial payment levels for a total sale and for sale of surplus. Additional remarks are made regarding the energy production level, guarantee deposit, certificate of compliance, communication between producer and network manager, rules to define the limits of a site, purchase contract duration, the E coefficient, and possible criteria for photovoltaic modules. The document ends with the statement of the CRE opinion on this decree project

  18. The insurance of nuclear installations

    Francis, H.W.

    1977-01-01

    A brief account is given of the development of nuclear insurance. The subject is dealt with under the following headings: the need for nuclear insurance, nuclear insurance pools, international co-operation, nuclear installations which may be insured, international conventions relating to the liability of operators of nuclear installations, classes of nuclear insurance, nuclear reactor hazards and their assessment, future developments. (U.K.)

  19. Build up of Radioactive Krypton and Xenon Analysis System

    Lee, D. K.; Choi, C. S.; Chung, K. H.; Lee, W.; Cho, Y. H.; Lee, C. W.

    2008-03-01

    The objective of this project is to build up an analysis system to measure the activity of the atmospheric radioactive krypton and xenon in Korea. The work scopes of the project include the purchase and the installation of the analysis system to measure the activity of the radioactive krypton and xenon in air, and the establishment of the operation capability of the system through the training of the operator. The system consists of two air sampling systems, and one radioactivity analysis system, which incorporates the enrichment system, the gas chromatography to purify a mixture gas, and the gas proportional counter to count the activity of pure krypton and xenon gas. As planned originally, the establishment of the analysis system has been completed. At present, one air sampler is successfully being operated at a specific site of the South Korea to measure the background radioactivities of Kr-85 and Xe-133 in air. The other air sampler is being reserved at the KAERI in the Daejeon for a emergency like the second nuclear test of the North Korea. During the normal time, the reserved air sampler will be used to collect the air sample for the performance test of the analysis system and the cross analysis for the calibration of the system. The radioactivity analysis system has been installed at the KAERI, and is being used to measure the activity of Kr-85 and Xe-133 in the air sample from a domestic site

  20. Designing in-building optical fiber networks

    Koonen, A.M.J.; Boom, van den H.P.A.; Tangdiongga, E.; Jung, H.D.; Guignard, P.

    2010-01-01

    Optical fiber in-building networks carrying wired and wireless services can outperform CAT-5E networks regarding versatility and installation costs. POF-based point-to-point architectures are optimum for small buildings, and (optically routed) SMF-based bus architectures for larger buildings.

  1. Installation of Cacouna Energy's liquefied natural gas terminal : public inquiry report; Projet d'implantation du terminal methanier Energie Cacouna : rapport d'enquete et d'audience publique

    Cosgrove, W.J. (comp.)

    2006-11-15

    This paper discussed the proposed construction of a liquefied natural gas (LNG) terminal 15 km northeast of Riviere-du-Loup, Quebec, in area that has strong land and marine biodiversity. The proposed project to import LNG for the North American market would involve the construction of ship docking facilities, transhipment facilities, and ground storage facilities. Quebec's environmental agency, the Bureau d'audiences publiques sur l'environnement (BAPE) examined the sustainability of the project with respect to biophysical aspects, social, economic and cultural development, as well as the environment, health, and public safety. Public hearings for the project attracted many citizens, First Nation groups and corporations with two opinions, for and against the project. Those in favour mentioned that Quebec must diversify its usual source of LNG from the west and that the project would promote competition. People at the public hearing expressed concerns for the quality of life, public health, air quality, noise pollution, visual impairment of the landscape, the security related to the operations of the terminal and navigation, public safety, recreational activities, marine mammals, fish, birds, animals, marshlands, greenhouse gas emissions, water pollution and soil pollution. This paper also outlined the state of the North-American market for LNG and its evolution; LNG supply and demand for the next twenty years; changes in gas prices; and emergency planning for the implementation of the project. BAPE recommended that the environmental monitoring and tracking be done by a project proponent. It was concluded that the proposed project would create competition with western Canada due to continually higher LNG prices, and would promote local jobs during the construction phase. 41 refs., 7 tabs., 8 figs.

  2. AWAKE starts the equipment installation phase

    Antonella Del Rosso

    2015-01-01

    AWAKE is the proof-of-principle experiment whose aim is to use protons to generate powerful wakefields to accelerate an electron beam. With accelerator gradients hundreds of times higher than those used in current systems, this technique could revolutionise the field of particle acceleration. Installed in the tunnel previously used by the CNGS facility, AWAKE is completing the service installation phase and will receive the plasma cell in the coming months.   The AWAKE proton line with all the magnets installed. (Image: AWAKE collaboration.) AWAKE is the world’s first proton-driven plasma wakefield acceleration experiment. In AWAKE, a beam of protons from the SPS will be travelling through a plasma cell and this will generate a wakefield that, in turn, will accelerate an electron beam. A laser will ionise the gas in the plasma cell and seed the self-modulation instability that will trigger the wakefield in the plasma. The project aims to prove that the plasma wakefield can be driv...

  3. DOD low energy model installation program

    Fournier, D.F. Jr.

    1993-01-01

    The Model Low Energy Installation Program is a demonstration of an installation-wide, comprehensive energy conservation program that meets the Department of Defense (DoD) energy management goals of reducing energy usage and costs by at least 20%. It employs the required strategies for meeting these goals, quantifies the environmental compliance benefits resulting from energy conservation and serves as a prototype for DoD wide application. This project will develop both analysis tools and implementation procedures as well as demonstrate the effectiveness of a comprehensive, coordinated energy conservation program based on state-of-the-art technologies. A military installation is in reality a small to medium sized city. It generally has a complete utilities infrastructure including water supply and distribution, sewage collection and treatment, electrical supply and distribution, central heating and cooling plants with thermal distribution, and a natural gas distribution system. These utilities are quite extensive and actually consume about 10-15% of the energy on the facility not counting the energy going into the central plants

  4. Cost-effectiveness of solar energy in energy-efficient buildings

    Kessler, S.; Iten, R.; Vettori, A.; Haller, A.; Ochs, M.; Keller, L.

    2005-01-01

    This report for the Swiss Federal Office of Energy (SFOE) presents the results of a study that examined the potentials and restraints with respect to the use of solar energy in the new construction and refurbishment of residential buildings in Switzerland. The method used is based on a 'learning-curve' technique. The first part of the report deals with the development of prices for solar-collector installations from 1990 until now. The second part deals with today's costs and future developments up to the year 2030. A reference building is used as the basis for the comparison of eight system variants. A further eight variants combine solar technology with traditional heating installations such as oil, gas and wood boilers and heat-pumps. Scenarios for the market situation for solar energy in 2030 are discussed

  5. Optimisation of a green gas supply chain--a review.

    Bekkering, J; Broekhuis, A A; van Gemert, W J T

    2010-01-01

    In this review the knowledge status of and future research options on a green gas supply based on biogas production by co-digestion is explored. Applications and developments of the (bio)gas supply in The Netherlands have been considered, whereafter literature research has been done into the several stages from production of dairy cattle manure and biomass to green gas injection into the gas grid. An overview of a green gas supply chain has not been made before. In this study it is concluded that on installation level (micro-level) much practical knowledge is available and on macro-level knowledge about availability of biomass. But on meso-level (operations level of a green gas supply) very little research has been done until now. Future research should include the modeling of a green gas supply chain on an operations level, i.e. questions must be answered as where to build digesters based on availability of biomass. Such a model should also advise on technology of upgrading depending on scale factors. Future research might also give insight in the usability of mixing (partly upgraded) biogas with natural gas. The preconditions for mixing would depend on composition of the gas, the ratio of gases to be mixed and the requirements on the mixture.

  6. Successful pipeline installation for Parque das Conchas development; Subsea installation

    Bartz, Cesar

    2010-07-01

    Subsea 7 has successfully delivered again in Brazilian deep-waters. The subsea engineering and construction company has recently completed pipeline installation activities for the Parque das Conchas (BC-10) development, offshore Brazil. (AG)

  7. Natural gas in low energy house Zittau

    Maertens, L.; Koschack, A.

    1999-01-01

    This paper describes a low-energy house in Zittau, Germany. The house consists of two parts A and B. Part A is heated by means of gas boilers and condensed boilers, while part B is solar heated. Energy for heating and warming of tap water is an important part of the primary energy consumption in Germany. Therefore, one way of reducing the CO2 emissions is to reduce the heat losses of buildings through outer facades and air ventilation, to use regenerative energy sources, to use fuels with low CO2 emissivity like natural gas, and to install efficient heating- and hot water preparation systems. The low-energy house in Zittau is used for energy research

  8. The installations of the Amsterdam town hall annex music theatre. Het stadhuis/muziektheater te Amsterdam, zitten daar ookinstallaties in

    Huijben, J.W.

    1989-10-01

    The following systems within the title building are discussed:installations to produce heat or cold energy; air treatment andventilation systems; high-voltage installations and energy conservationmeasures; low-voltage installations; transport systems and stageinstallations. In particular mechanical engineering, the electricalinstallations and the energy conservation measures are highlighted. 13figs.

  9. Wood Pellet-Fired Biomass Boiler Project at the Ketchikan Federal Building

    Tomberlin, Gregg [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-06-01

    Biomass boiler systems have existed for many years, but the technology has advanced in recent decades and can now provide automated and efficient operation for a relatively modest investment. Key advances in system monitoring and control allow for lower operating costs, since the control systems run all aspects of the boiler, including feed, load reduction and even tube cleaning. These advances have made such systems economical on a small scale in situations where inexpensive fuels like natural gas are not available. This creates an opportunity for building operators in remote, cold-climate locations to reduce the use of expensive fuels for heating buildings. GSA Region 10 installed the system at the federal building in Ketchikan, Alaska and submitted the project to the Green Proving Ground (GPG) program. GSA's GPG program contracted with the National Renewable Energy Laboratory (NREL) to assess the installation and the technology. The system serves as a demonstration to assess actual system efficiencies, as well as operating characteristics and financial benefits. In addition to installation and operational issues, the project team/researchers examined other issues, including fuel transportation costs, building energy savings, and overall economics.

  10. A supermolecular building layer approach for gas separation and storage applications: the eea and rtl MOF platforms for CO 2 capture and hydrocarbon separation

    Chen, Zhijie; Adil, Karim; Weselinski, Lukasz Jan; Belmabkhout, Youssef; Eddaoudi, Mohamed

    2015-01-01

    The supermolecular building layer (SBL) approach was employed to deliberately synthesize five novel metal–organic frameworks (1–5) with an exposed array of amide or amine functionalities within their pore system. The ability to decorate the pores

  11. Experience with building integrated solar collectors; Erfaring med bygningsintegrerte solfangere

    Simonsen, Ingeborg; Time, Berit; Andresen, Inger

    2011-07-01

    The main objective of the research 'Zero Emission Buildings' ZEB is to develop products and solutions that provide buildings with zero greenhouse gas emissions associated with the production, operation and disposal. Can we make this happen must the building produce more energy than it needs to compensate for greenhouse gas emissions from the production of materials and the actual construction.To build up knowledge on experience with building integrated solar collectors in Norway, we have in this study made interviews with suppliers and manufacturers of solar collectors and some building owners. Since the focus is on climate shell, we have limited the study to include solar collectors to replace a part of the cladding or roofing. Construction upstairs roofing, outside facade or freestanding rack is not considered as building integrated in this context. The providers we have been in contact with appeals to slightly different parts of the market. This is reflected in the product's development, assembly and approach to the calculation of energy delivery. Overall, providers may offer a range of products suitable for both the professional and skilled carpenter, the interested 'man in the street' . The feedback we have received shows generally good experiences with the product and the installation. Because of the preliminary short operating periods of the investigated plants we have little data on energy supply from these plants. In summary, we can say that the knowledge and the products are available and it is up to use to use them.(Author)

  12. LHCb Dockerized Build Environment

    Clemencic, M.; Belin, M.; Closier, J.; Couturier, B.

    2017-10-01

    Used as lightweight virtual machines or as enhanced chroot environments, Linux containers, and in particular the Docker abstraction over them, are more and more popular in the virtualization communities. The LHCb Core Software team decided to investigate how to use Docker containers to provide stable and reliable build environments for the different supported platforms, including the obsolete ones which cannot be installed on modern hardware, to be used in integration builds, releases and by any developer. We present here the techniques and procedures set up to define and maintain the Docker images and how these images can be used to develop on modern Linux distributions for platforms otherwise not accessible.

  13. Solar Installation Labor Market Analysis

    Friedman, B.; Jordan, P.; Carrese, J.

    2011-12-01

    The potential economic benefits of the growing renewable energy sector have led to increased federal, state, and local investments in solar industries, including federal grants for expanded workforce training for U.S. solar installers. However, there remain gaps in the data required to understand the size and composition of the workforce needed to meet the demand for solar power. Through primary research on the U.S. solar installation employer base, this report seeks to address that gap, improving policymakers and other solar stakeholders understanding of both the evolving needs of these employers and the economic opportunity associated with solar market development. Included are labor market data covering current U.S. employment, expected industry growth, and employer skill preferences for solar installation-related occupations. This study offers an in-depth look at the solar installation sectors. A study published by the Solar Foundation in October 2011 provides a census of labor data across the entire solar value chain.

  14. Installation of the Gbar LINAC

    Maximilien, Brice

    2017-01-01

    Installation of the GBAR linac in its shielding bunker. The electrons accelerated to 10 MeV toward a target will produce the positrons that are necessary to form anti hydrogen with the antiprotons coming from the ELENA decelerator.

  15. DAQ INSTALLATION IN USC COMPLETED

    A. Racz

    After one year of work at P5 in the underground control rooms (USC55-S1&S2), the DAQ installation in USC55 is completed. The first half of 2006 was dedicated to the DAQ infrastructures installation (private cable trays, rack equipment for a very dense cabling, connection to services i.e. water, power, network). The second half has been spent to install the custom made electronics (FRLs and FMMs) and place all the inter-rack cables/fibers connecting all sub-systems to central DAQ (more details are given in the internal pages). The installation has been carried out by DAQ group members, coming from the hardware and software side as well. The pictures show the very nice team spirit !

  16. Nuclear installations and their environment

    Rieu, Ch.; Berge-Thierry, C.; Duval, C.; Bonnet, Ch.; Gaubert, B.; Riffard, Th.; Greffier, G.; Cervantes, J.C.; Le Breton, F.; Clement, C.; Charbonnier, R.; Andreani, A.M.; Maubert, H.; Maisonneuve, A.

    2002-01-01

    This dossier deals with protection of nuclear installations against external risks. The articles come from the presentations of the Conference on 'Nuclear installations and their environment', held by the 'Safety and Environment Protection' Section of the French Nuclear Energy Society on October 15, 2002. Floods, earthquakes, winter cold, snow-falls, wind, fires are the main natural risks taken into account. Risks from industrial environment and communication lines are also considered. (authors)

  17. Suitcase to Audit Solar Installations

    Alberdi, J.; Barcala, J.M.; Blas de, J.; Molinero, A.; Navarrete, J.J.; Yuste, C.

    2001-07-01

    The audit suitcase was proposed by BESEL to introduce in the solar energy market a new tool which can make an evaluation of solar installation efficiency. Non-invasive sensors and low power components permit both easy installation of the devices and data storage for a period as long as ten days. This project was funded by the contract JOR3-CT98-7030 of the European Union JOULE III program. (Author)

  18. Suitcase to Audit Solar Installations

    Alberdi, J.; Barcala, J. M.; Blas, J. de; Molinero, A.; Navarrete, J. J.; Yuste, C.

    2001-01-01

    The audit suitcase was proposed by BESEL to introduce in the solar energy market a new tool which can make an evaluation of solar installation efficiency. Non-invasive sensors and low power components permit both easy installation of the devices and data storage for a period as long as ten days. This project was funded by the contract JOR3-CT98-7030 of the European Union JOULE III program. (Author)

  19. Improving Gas Furnace Performance: A Field and Laboratory Study at End of Life

    Brand, L. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States); Yee, S. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States); Baker, J. [Partnership for Advanced Residential Retrofit (PARR), Des Plaines, IL (United States)

    2015-02-01

    In 2010, natural gas provided 54% of total residential space heating energy the U.S. on a source basis, or 3.5 Quadrillion Btu. Natural gas burned in furnaces accounted for 92% of that total, and boilers and other equipment made up the remainder. A better understanding of installed furnace performance is a key to energy savings for this significant energy usage. In this project, the U.S. Department of Energy Building America team Partnership for Advanced Residential Retrofit examined the impact that common installation practices and age-induced equipment degradation may have on the installed performance of natural gas furnaces over the life of the product, as measured by steady-state efficiency and annual efficiency. The team identified 12 furnaces of various ages and efficiencies that were operating in residential homes in the Des Moines, Iowa, metropolitan area and worked with a local heating, ventilation, and air conditioning contractor to retrieve furnaces and test them at the Gas Technology Institute laboratory for steady-state efficiency and annual efficiency. Prior to removal, system airflow, static pressure, equipment temperature rise, and flue loss measurements were recorded for each furnace as installed in the house.

  20. Mapping the performance of wood-burning stoves by installations worldwide

    Luis Teles de Carvalho, Ricardo; Jensen, Ole Michael; Tarelho, Luis A. C.

    2016-01-01

    environmental health risk. Research stressed the need to increase the performance of conventional interplays between users, stoves and buildings. This scientific review aims to characterize the performance and environmental effects of 9 wood-burning stove categories by installations worldwide...

  1. Planning and building a gas cave store in Bremen-Lesum; Planung und Errichtung von einem Gaskavernenspeicher in Bremen-Lesum

    Kossert, J.; Schultz, K.F. [Mobil Erdgas Erdoel GmbH, Celle (Germany)

    1998-12-31

    In order to supply sufficient natural gas to the Northern part of Germany Mobil set up a gas cave storage in Bremen Lesum. Drilling- and brine engineering, plant design, electricity supply, brine plant are described. Remote control, personnel planning, operational experience and plants for gas operation as well as pipelines, compressors and gas drying are described. [Deutsch] Um kuenftig den Spitzenbedarf nach umweltfreundlichem Erdgas in Norddeutschland befriedigen zu koennen, errichtete Mobil einen Gaskavernenspeicher in Bremen Lesum. Im Folgenden wird die Bohr-und Soltechnik, die Anordnung der Anlagenteile, die Elektroversorgung der Solanlage sowie der Solbetrieb naeher erlaeutert. Ausserdem werden die Fernueberwachung, der Personaleinsatz, die Betriebserfahrungen und die Anlagen fuer den Gasbetrieb wie Verbindungsleitung, Kompressoranlage und Gastrocknungsanlage beschrieben.(msk)

  2. Public building retrofit

    1982-01-01

    This report demonstrates the economic viability of cost effective, energy efficient retrofitting of a public building. The Whitehorse Chamber of Commerce in conjunction with the Canada/Yukon Conservation and Renewable Energy Demonstration Project undertook the demonstration project. The energy conservation features included increasing the insulation in the walls and ceiling, providing a 6 mm polyethylene air-vapour barrier and installing triple glazed windows on the north side. Also, an air-to-air heat exchanger and a combination wood/oil furnace were installed. However, neither of these latter features have been used since the completion of the renovations. In total, the features cost approximately $26,300. The energy conservation measures yielded less energy savings than expected. Although the T.C. Richard building is now consuming less heating oil (33% less); the amount of electricity used has increased by 146.6%. Overall the building achieved a 23% reduction in heating consumption (this figure takes into account the heat energy generated from the lighting system). Reasons for the low yield in energy savings can be attributed to the improper installation of the air-vapour barrier and not using the existing wood boiler. 1 fig. 5 tabs.

  3. Solving Confliction Problem Between the Gas Turbine Generator Seal-oil System and Building Steel Structure%燃机发电机密封油系统与钢结构碰撞问题之解决

    陈闻菲; 杨承佐

    2014-01-01

    国内某燃机联合循环电厂在建设阶段发生了的发电机密封油系统布置与厂房钢结构碰撞的问题。在听取设计人员及专家意见后,分析了问题产生的原因,提出了解决办法。%The confliction between gas turbine gen-erator seal-oil system and GT (Gas turbine) building steel structure happened during the constructive stage of a do-mestic CCPP (Combined cycle power plant). After listening to the opinions of the experts, cause to result in the problem was analyzed and solving way was suggested.

  4. Magnetic resonance imaging: project planning and management of a superconductive M.R.I. installation

    Condon, P.M.; Robertson, A.R.

    1989-01-01

    The planning and installation of a Superconductive Magnetic Resonance Imaging installation at the Royal Adelaide Hospital, Adelaide, South Australia is described. Tender specification, assessment of offers via criteria weighted analysis of technical and economic factors and the final recommendation for a 1.0 Tesla unit are discussed. Building and installation considerations are noted including fringe field effects, magnetic shielding, radiofrequency shielding, cryogens, metallic screening and specific considerations in the Magnet room. 9 refs., 7 figs

  5. Physical installation of Pelletron and electron cooling system

    Hurh, P.

    1997-01-01

    Bremsstrahlung of 5 MeV electrons at a loss current of 50 microamp in the acceleration region is estimated to produce X-ray intensities of 7 Rad/sec. Radiation losses due to a misteer or sudden obstruction will of course be much higher still (estimated at 87,500 Rad/hr for a 0.5 mA beam current). It is estimated that 1.8 meters of concrete will be necessary to adequately shield the surrounding building areas at any possible Pelletron installation site. To satisfy our present electron cooling development plan, two Pelletron installations are required, the first at our development lab in the Lab B/NEF Enclosure area and the second at the operational Main Injector service building, MI-30, in the main Injector ring. The same actual Pelletron and electron beam-line components will be used at both locations. The Lab B installation will allow experimentation with actual high energy electron beam to develop the optics necessary for the cooling straight while Main Injector/Recycler commissioning is taking place. The MI-30 installation is obviously the permanent home for the Pelletron when electron cooling becomes operational. Construction plans for both installations will be discussed here

  6. Biogas: the support arrangement is extended to hybrid valorization installations

    2013-01-01

    This document presents and contains three decrees which authorize the hybrid valorization of biogas, i.e. by production of electricity and of bio-methane which is injected in natural gas networks, in order to support the development of methanization. Prospect development, tariff and contract duration are briefly discussed. The decrees address the contracting conditions between bio-methane producers and natural gas providers, purchase conditions for the electricity produced by biogas installations, purchase conditions of bio-methane injected in natural gas networks. The document also contains the discussion the Commission of energy regulation about the first decree

  7. Steam System Balancing and Tuning for Multifamily Residential Buildings in Chicagoland - Second Year of Data Collection

    Choi, J.; Ludwig, P.; Brand, L.

    2013-08-01

    Steam heated buildings often suffer from uneven heating as a result of poor control of the amount of steam entering each radiator. In order to satisfy the heating load to the coldest units, other units are overheated. As a result, some tenants complain of being too hot and open their windows in the middle of winter, while others complain of being too cold and are compelled to use supplemental heat sources. Building on previous research, CNT Energy identified 10 test buildings in Chicago and conducted a study to identify best practices for the methodology, typical costs, and energy savings associated with steam system balancing. A package of common steam balancing measures was assembled and data were collected on the buildings before and after these retrofits were installed to investigate the process, challenges, and the cost effectiveness of improving steam systems through improved venting and control systems. The test buildings that received venting upgrades and new control systems showed 10.2% savings on their natural gas heating load, with a simple payback of 5.1 years. The methodologies for and findings from this study are presented in detail in this report. This report has been updated from a version published in August 2012 to include natural gas usage information from the 2012 heating season and updated natural gas savings calculations.

  8. Solar heating and hot water system installed at Charlotte Memorial Hospital, Charlotte, North Carolina

    1981-01-01

    Detailed information regarding the design and installation of a heating and hot water system in a commercial application is given. This information includes descriptions of system and building, design philosophy, control logic operation modes, design and installation drawing and a brief description of problems encountered and their solutions.

  9. Building Languages

    ... Glossary Contact Information Information For… Media Policy Makers Building Languages Recommend on Facebook Tweet Share Compartir Communicating ... any speech and only very loud sounds. Close × “Building Blocks” “Building Blocks” refers to the different skills ...

  10. Solar system installation at Louisville, Kentucky (final report)

    1978-08-07

    A contract was awarded in June 1976 for the installation of a solar space heating and domestic hot water system at 2400 Watteroon Trail, Louisville, Kentucky. The overall philosophy used was to install both a liquid and a hot air system retrofitted to the existing office and combined warehouse building. The 1080 sq ft office space is heated first and excess heat is dumped into the warehouse. The two systems offered a unique opportunity to measure the performance and compare results of both air and liquid at one site. The two systems are described in detail and information on the data acquisition system is included.

  11. IMCOM LonWorks (registered trademark) Building Automation Systems Implementation Strategy

    Schwenk, David M; Bush, Joseph; Hughes, Lucie M; Briggs, Stephen; White, Will

    2008-01-01

    Army Installations often expand their use of digital control systems for heating, ventilating, and air conditioning and other mechanical and electrical building systems on a building-by-building basis...

  12. Displacement pile installation effects in sand

    Beijer-Lundberg, A.

    2015-01-01

    Installation effects govern the post-installation behaviour of displacement piles in sand. These effects are currently not completely understood. Suitable experimental techniques to model these installation effects include field, laboratory and experimental models. In the current thesis a

  13. Interotex-innovative gas equipment for heating and cooling

    Winnington, T.L. [Interotex Ltd. (United Kingdom); Moore, N. [British Gas plc (United Kingdom); Valle, F.; Sanz, J. I. [Gas Natural SDG S.A. (Spain); Chavarri, J.M. [Fagor Electrodomesticos S. Coop. (Spain); Uselton, R. [Lennox Industries Inc. (United States)

    1997-10-01

    Conventionally, cooling technology for the residential market is provided by electrically driven vapour re-compression systems. But lately, due to the Montreal Protocol - restricting the utilisation of ozone depleting substances - and to the high peak demand in electricity, created by electrical air conditioning systems, there is a commercial opportunity for gas fired air conditioning appliances. This paper describes the development programme for a radical new absorption technology, from the theoretical studies, through the experimental programme, to the building, commissioning and installation of demonstration machines. It also includes an analysis of the world-wide residential cooling market and the opportunities available to manufacturers and gas utilities to introduce new gas heating and cooling technology, capable of competing effectively with electrical systems. (au)

  14. Energy efficiency measures for offshore oil and gas platforms

    Nguyen, Tuong-Van; Voldsund, Mari; Breuhaus, Peter

    2016-01-01

    . They include: (i) the installation of multiple pressure levels in production manifolds, (ii) the implementation of multiphaseexpanders, (iii) the promotion of energy and process integration, (iv) the limitation of gas recirculation around the compressors, (v) the exploitation of low-temperature heat from...... the gas cooling steps, (vi) the downsizing or replacement of the existing gas turbines, and (vii) the use of the waste heat from the powerplant. The present study builds on four actual cases located in the North and Norwegian Seas, which differ by the type of oil processed, operating conditions...... and strategies. The benefits and practical limitations of each measure are discussed based on thermodynamic, economic and environmental factors. Signiffcant energy savings and reductions in CO2-emissions are depicted, reaching up to 15-20 %. However, they strongly differ from one facility to another, which...

  15. New method and installation for rapid determination of radon diffusion coefficient in various materials

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-01-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10 −12 to 5·10 −5 m 2 /s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). - Highlights: • The new method and installation for determination of radon diffusion coefficient D are developed. • The measured D-values vary in an extremely wide range, from 5×10 -5 to 1×10 -12 m 2 /s. • The materials include water, air, soil, building materials and radon-proof membranes. • The duration of the single test does not exceed 18 hours. • The measurement uncertainty varies from 5% (in permeable materials) to 40% (in radon gas barriers)

  16. Safety reassessment of the old installations involved in fuel cycle

    Guillard, M

    2003-01-01

    Since the early 1990's, CEA (French atomic energy commission) has been preparing a plan for the renovation of a laboratory situated at Cadarache and dedicated to the study of irradiated materials and fuels. The main aim of this renovation was the improvement of the seismic behaviour of the laboratory since it was not built according to the para-seismic rules now in force. The solution chosen, given the different projects studied, the provisional unavailability of the plant and the related costs, was a partial reinforcement of the building in association with a limited plant life time and the reduction of activities in the oldest part of the installation. Another aim of this renovation was a global upgrading of the safety concerning: -) radioactive material containment (upgrade of the first static barrier by reinforcing cell leak-proofing, installation of a second level of very high efficiency filtration at the cell outputs, and separation of cell and general building ventilation networks; -) fire protection (fire sectoring with the isolation of the premises involving safety-important equipment, replacement of the automatic fire detection system, and definition of a new piloting of ventilation in case of fire); -) power cut risks (installation of permanent sources for the power supply of safety-important equipment); and -) earthquake behaviour (addition of reinforced connections between the 3 parts of the building, strengthening of peripheral walls, widening of joints between cells and building, and reinforcement of the foundation of the concrete cells). (A.C.)

  17. Safety reassessment of the old installations involved in fuel cycle

    Guillard, M.

    2003-01-01

    Since the early 1990's, CEA (French atomic energy commission) has been preparing a plan for the renovation of a laboratory situated at Cadarache and dedicated to the study of irradiated materials and fuels. The main aim of this renovation was the improvement of the seismic behaviour of the laboratory since it was not built according to the para-seismic rules now in force. The solution chosen, given the different projects studied, the provisional unavailability of the plant and the related costs, was a partial reinforcement of the building in association with a limited plant life time and the reduction of activities in the oldest part of the installation. Another aim of this renovation was a global upgrading of the safety concerning: -) radioactive material containment (upgrade of the first static barrier by reinforcing cell leak-proofing, installation of a second level of very high efficiency filtration at the cell outputs, and separation of cell and general building ventilation networks; -) fire protection (fire sectoring with the isolation of the premises involving safety-important equipment, replacement of the automatic fire detection system, and definition of a new piloting of ventilation in case of fire); -) power cut risks (installation of permanent sources for the power supply of safety-important equipment); and -) earthquake behaviour (addition of reinforced connections between the 3 parts of the building, strengthening of peripheral walls, widening of joints between cells and building, and reinforcement of the foundation of the concrete cells). (A.C.)

  18. Risk Analysis of Flare Flame-out Condition in a Gas Process Facility Analyse des risques des conditions d’extinction de torche au sein d’une installation de traitement de gaz

    Zadakbar O.

    2011-02-01

    Full Text Available Flaring is a common method of disposal of flammable waste gases in the downstream industries. Flare flame out (flame lift-off or blow-outs often occurs causing toxic vapors to discharge. The toxic gases released may have hazardous effects on the surrounding environment. To study the effect of inhalation exposure of these toxic gases on human health, the four steps of the EPA (Environmental Protection Agency framework with the field data to quantify the cancer and non-cancer health risks are integrated in this paper. As a part of exposure assessment, gas dispersion modeling using AERMOD and UDM-PHAST is applied in two different conditions of normal flaring and flare flame out during a particular climate condition in Khangiran region. Recommendations to avoid flare flame out conditions are also presented here. Le torchage est un procédé courant d’élimination des gaz résiduaires inflammables dans les industries de traitement. L’extinction de la torche (par décollage ou soufflage de flamme provoque souvent une émission de vapeurs toxiques. Ces gaz toxiques libérés peuvent présenter des effets dangereux sur le milieu environnant. Pour étudier l’effet d’une exposition par inhalation de ces gaz toxiques sur la santé, cet article croise les quatre étapes de la démarche de l’EPA (Environmental Protection Agency, Agence de protection de l’environnement avec les données d’exploitation afin de quantifier le risque sanitaire cancérologique et non cancérologique. Dans le cadre de l’estimation d’exposition, une modélisation de dispersion des gaz utilisant AERMOD et UDM-PHAST est évaluée dans deux configurations différentes de torchage normal et d’extinction de torche à l’occasion de conditions climatiques particulières dans la région du Khangiran. L’article propose également des recommandations destinées à éviter les conditions d’une extinction de flamme de torche.

  19. Evaluating the need for economic support policies in promoting greenhouse gas emission reduction measures in the building sector: The case of Greece

    Georgopoulou, E.; Sarafidis, Y.; Mirasgedis, S.; Balaras, C.A.; Gaglia, A.; Lalas, D.P.

    2006-01-01

    During the last decade the CO 2 emissions from the residential and tertiary sectors have been rising continuously. This is cause for concern but also an area to be targeted for emission reduction measures in national action plans. This paper proposes a methodological framework, using the Greek building sector (characterized by an aging building stock constructed mostly in the period before 1980) as a case study for the examination of the economic attractiveness of possible measures, which incorporates crucial parameters such as local climate, use of buildings, age of building stock, etc. that affect the energy conservation potential and consequently the economic performance of available measures. Utilizing this framework, the approach is able to classify measures into three categories, namely 'win-win' cases (i.e. where the implementation of emission reduction measures presents a net economic benefit for end-users), measures that require the implementation of appropriate economic support policies in order to make them economically attractive for end-users, and measures that have excessive cost. The results indicate that the emissions reduction potential of 'win-win' cases is significant. They also demonstrate how individual measures can provide significant reductions if carefully targeted economic support policies are applied. Finally, sensitivity analyses performed with respect to the discount rate applied indicate that it has a substantial impact on the economic performance of some measures and consequently on the magnitude of the 'win-win' potential associated to emissions reduction

  20. Second update of the database of photovoltaic installations in the UK

    Taylor, D; Bruhns, H

    2001-07-01

    This update of the database of photovoltaic (PV) installations in the UK developed by Altechnica for the Department of Trade and Industry has double the number of records of the previous edition, and focuses on the use of photovoltaic (PV) installations for buildings, for example using some form of a PV array, building integrated PV module, and building attached PV array. The growth in building related PV installations is examined along with the use of PV in telecommunication equipment, navigation buoys and light vessels, buildings, pumps for solar water heating systems, schools, lighthouses, and petrol stations. Details are given of the electronic data entry form for the database and the increase in the number of fields to allow additional information such as tilt angle and orientation area of the array to be added.

  1. Building America Case Study: Addressing Multifamily Piping Losses with Solar Hot Water, Davis, California

    2016-12-01

    Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

  2. Using Solar Hot Water to Address Piping Heat Losses in Multifamily Buildings

    Springer, David [Alliance for Residential Building Innovation, Davis, CA (United States); Seitzler, Matt [Alliance for Residential Building Innovation, Davis, CA (United States); Backman, Christine [Alliance for Residential Building Innovation, Davis, CA (United States); Weitzel, Elizabeth [Alliance for Residential Building Innovation, Davis, CA (United States)

    2015-10-01

    Solar thermal water heating is most cost effective when applied to multifamily buildings and some states offer incentives or other inducements to install them. However, typical solar water heating designs do not allow the solar generated heat to be applied to recirculation losses, only to reduce the amount of gas or electric energy needed for hot water that is delivered to the fixtures. For good reasons, hot water that is recirculated through the building is returned to the water heater, not to the solar storage tank. The project described in this report investigated the effectiveness of using automatic valves to divert water that is normally returned through the recirculation piping to the gas or electric water heater instead to the solar storage tank. The valves can be controlled so that the flow is only diverted when the returning water is cooler than the water in the solar storage tank.

  3. The safety of nuclear installations

    1993-01-01

    This Safety Fundamental publication sets out basic objectives, concepts and principles for ensuring safety that can be used both by the IAEA in its international assistance operations and by Member States in their national nuclear programmes. These Safety Fundamentals apply primarily to those nuclear installations in which the stored energy developed in certain situations could potentially results in the release of radioactive material from its designated location with the consequent risk of radiation exposure of people. These principles are applicable to a broad range of nuclear installations, but their detailed application will depend on the particular technology and the risks posed by it. In addition to nuclear power plants, such installations may include: research reactors and facilities, fuel enrichment, manufacturing and reprocessing plants; and certain facilities for radioactive waste treatment and storage

  4. The Creation of a French Basic Nuclear Installation - Description of the Regulatory Process - 13293

    Mahe, Carole [CEA Marcoule - BP17171 - 30207 Bagnols-Sur-Ceze (France); Leroy, Christine [CEA Cadarache - 13108 Saint Paul-Lez-Durance (France)

    2013-07-01

    CEA is a French government-funded technological research organization. It has to build a medium-level waste interim storage facility because the geological repository will not be available until 2025. This interim storage facility, called DIADEM, has to be available in 2017. These wastes are coming from the research facilities for spent fuel reprocessing and the dismantling of the most radioactive parts of nuclear facilities. The CEA handles the waste management by inventorying the needs and updating them regularly. The conception of the facility is mainly based on this inventory. It provides quantity and characteristics of wastes and it gives the production schedule until 2035. Beyond mass and volume, main characteristics of these radioactive wastes are chemical nature, radioisotopes, radioactivity, radiation dose, the heat emitted, corrosive or explosive gas production, etc. These characteristics provide information to study the repository safety. DIADEM mainly consists of a concrete cell, isolated from the outside, wherein stainless steel welded containers are stored, stacked in a vertical position in the racks. DIADEM is scheduled to store three types of 8 mm-thick, stainless steel cylindrical containers with an outside diameter 498 mm and height from 620 to 2120 mm. DIADEM will be a basic nuclear installation (INB in French) because of overall activity of radioactive substances stored. The creation of a French basic nuclear installation is subject to authorization according to the French law No. 2006-686 of 13 June 2006 on Transparency and Security in the Nuclear Field. The authorization takes into account the technical and financial capacities of the licensee which must allow him to conduct his project in compliance with these interests, especially to cover the costs of decommissioning the installation and conduct remediation work, and to monitor and maintain its location site or, for radioactive waste disposal installations, to cover the definitive shut

  5. The Creation of a French Basic Nuclear Installation - Description of the Regulatory Process - 13293

    Mahe, Carole; Leroy, Christine

    2013-01-01

    CEA is a French government-funded technological research organization. It has to build a medium-level waste interim storage facility because the geological repository will not be available until 2025. This interim storage facility, called DIADEM, has to be available in 2017. These wastes are coming from the research facilities for spent fuel reprocessing and the dismantling of the most radioactive parts of nuclear facilities. The CEA handles the waste management by inventorying the needs and updating them regularly. The conception of the facility is mainly based on this inventory. It provides quantity and characteristics of wastes and it gives the production schedule until 2035. Beyond mass and volume, main characteristics of these radioactive wastes are chemical nature, radioisotopes, radioactivity, radiation dose, the heat emitted, corrosive or explosive gas production, etc. These characteristics provide information to study the repository safety. DIADEM mainly consists of a concrete cell, isolated from the outside, wherein stainless steel welded containers are stored, stacked in a vertical position in the racks. DIADEM is scheduled to store three types of 8 mm-thick, stainless steel cylindrical containers with an outside diameter 498 mm and height from 620 to 2120 mm. DIADEM will be a basic nuclear installation (INB in French) because of overall activity of radioactive substances stored. The creation of a French basic nuclear installation is subject to authorization according to the French law No. 2006-686 of 13 June 2006 on Transparency and Security in the Nuclear Field. The authorization takes into account the technical and financial capacities of the licensee which must allow him to conduct his project in compliance with these interests, especially to cover the costs of decommissioning the installation and conduct remediation work, and to monitor and maintain its location site or, for radioactive waste disposal installations, to cover the definitive shut

  6. Transmission power control for wireless home and building automation

    Bacchiani, C.

    2015-01-01

    Home and building automation can provide significant improvements in comfort and energy efficiency of buildings. However, its diffusion is hindered by the complexity of installation and maintenance. Wireless connectivity can simplify this process, reducing installation time and cost, but it requires

  7. New electricity generating installations - Czech experience

    Biza, K.; Pazdera, F.; Zdarek, J.

    2004-01-01

    Economically and technically are analysed alternatives for new electricity generation installations (GEN 111+ NPPs, finalization of NPPs under construction, lifetime extension of existing NPPs, coal plants and gas plants). Described are experienced with NPP Temelin (lessons learned from its design, construction, start-up and resent operation and service experience) and new Czech Energy Policy, where the nuclear energy is an important source for electricity generation. Discussed is also impact of potential trading with CO 2 limits and strategy on minimization of dependence on energy from politically unstable regions. Underlined is important role of preparation of young generation for safe and reliable long term operation of NPPs. General recommendation is to orient on finalization of NPPs under construction, lifetime extension of existing NPPs and long term orientation on new generation of NPPs (GEN III+ and GEN IV). (author)

  8. Industrial installation surveillance acoustic device

    Marini, Jean; Audenard, Bernard.

    1981-01-01

    The purpose of this invention is the detection of possible impacts of bodies migrating inside the installation, using acoustic sensors of the waves emitted at the time of impact of the migrating bodies. This device makes it possible to take into account only those acoustic signals relating to the impacts of bodies migrating in the area under surveillance, to the exclusion of any other acoustic or electric perturbing phenomenon. The invention has a preferential use in the case of a linear shape installation in which a fluid flows at high rate, such as a section of the primary system of a pressurized water nuclear reactor [fr

  9. Facile Synthesis of a Hydroxyl-Functionalized Tröger’s Base Diamine: A New Building Block for High-Performance Polyimide Gas Separation Membranes

    Ma, Xiaohua; Abdul Hamid, Mahmoud; Miao, Xiaohe; Pinnau, Ingo

    2017-01-01

    the highest gas-pair permselectivity values of all reported OH-functionalized PIM-PIs to date. The high permselectivity of 6FDA-HTB resulted primarily from exceptional diffusion selectivity due to strong size-sieving properties caused by hydrogen bonding

  10. High temperature gas cleaning for pressurized gasification. Final report

    Alden, H.; Hagstroem, P.; Hallgren, A.; Waldheim, L. [TPS Termiska Processer AB, Nykoeping (Sweden)

    2000-04-01

    The purpose of the project was to build an apparatus to study pressurized, high temperature gas cleaning of raw gasification gas generated from biomass. A flexible and easy to operate pressurized apparatus was designed and installed for the investigations in high temperature gas cleaning by means of thermal, catalytic or chemical procedures. A semi continuos fuel feeding concept, at a maximum rate of 700 g/h, allowed a very constant formation of a gas product at 700 deg C. The gas product was subsequently introduced into a fixed bed secondary reactor where the actual gas cleanup or reformation was fulfilled. The installation work was divided into four work periods and apart from a few delays the work was carried out according to the time plan. During the first work period (January - June 1994) the technical design, drawings etc. of the reactor and additional parts were completed. All material for the construction was ordered and the installation work was started. The second work period (July - December 1994) was dedicated to the construction and the installation of the different components. Initial tests with the electrical heating elements, control system and gas supply were assigned to the third work period (January - June 1995). After the commissioning and the resulting modifications, initial pyrolysis and tar decomposition experiments were performed. During the fourth and final work period, (June - December 1995) encouraging results from first tests allowed the experimental part of the project work to commence, however in a slightly reduced program. The experimental part of the project work comparatively studied tar decomposition as a function of the process conditions as well as of the choice of catalyst. Two different catalysts, dolomite and a commercial Ni-based catalyst, were evaluated in the unit. Their tar cracking ability in the pressure interval 1 - 20 bar and at cracker bed temperatures between 800 - 900 deg C was compared. Long term tests to study

  11. Block Gas Sol Unit in Haderslev

    Vejen, Niels Kristian

    2000-01-01

    Investigation of a SDHW system based on a Block Gas Sol Unit from Baxi A/S installed by a consumer i Haderslev, Denmark.......Investigation of a SDHW system based on a Block Gas Sol Unit from Baxi A/S installed by a consumer i Haderslev, Denmark....

  12. Dauphin Island natural gas project

    Layfield, R.P.; Elser, K.L.; Ostler, R.H.

    1994-01-01

    Arco Oil and Gas Co. installed the Dauphin Island production facility in a fragile Alabama marine environment supporting important fisheries and tourist facilities. The authors used proactive communication with governmental agencies, area industry, and the public; innovative construction technologies; and unique platform design to minimize the environmental and aesthetic impacts and to develop an economically successful gas field. The innovative equipment used in the offshore pipeline installation is a model approach for solving certain turbidity problems. The project has received numerous environmental awards

  13. Dauphin Island natural gas project

    Layfield, R.P. (Arco International Oil and Gas Co., Plano, TX (United States)); Elser, K.L.; Ostler, R.H. (Arco Oil and Gas Co., Houston, TX (United States))

    1994-01-01

    Arco Oil and Gas Co. installed the Dauphin Island production facility in a fragile Alabama marine environment supporting important fisheries and tourist facilities. The authors used proactive communication with governmental agencies, area industry, and the public; innovative construction technologies; and unique platform design to minimize the environmental and aesthetic impacts and to develop an economically successful gas field. The innovative equipment used in the offshore pipeline installation is a model approach for solving certain turbidity problems. The project has received numerous environmental awards.

  14. Liquid natural gas. Japan

    Van Kooij, E.

    1998-01-01

    An overview is given of the technical know-how and expertise in Japan with respect to the supply, transport, storage and use of LNG. First the overall energy supply in Japan is outlined. Next, the reasons for the use of LNG as an energy source in Japan are discussed. As an example of a typical LNG-installation in Japan the construction of the Himeji Terminal of Osaka Gas Company is described. Finally, attention is paid to the world's largest and modern below-surface LNG-tanks (capacity of 200,000 m 3 ), installed at the Negishi Terminal of Tokyo Gas Company

  15. Wind and Solar Energy Resource Assessment for Navy Installations in the Midwestern US

    Darmenova, K.; Apling, D.; Higgins, G. J.; Carnes, J.; Smith, C.

    2012-12-01

    A stable supply of energy is critical for sustainable economic development and the ever-increasing demand for energy resources drives the need for alternative weather-driven renewable energy solutions such as solar and wind-generated power. Recognizing the importance of energy as a strategic resource, the Department of the Navy has focused on energy efficient solutions aiming to increase tactical and shore energy security and reduce greenhouse gas emissions. Implementing alternative energy solutions will alleviate the Navy installations demands on the National power grid, however transitioning to renewable energy sources is a complex multi-stage process that involves initial investment in resource assessment and feasibility of building solar and wind power systems in Navy's facilities. This study focuses on the wind and solar energy resource assessment for Navy installations in the Midwestern US. We use the dynamically downscaled datasets at 12 km resolution over the Continental US generated with the Weather Research and Forecasting (WRF) model to derive the wind climatology in terms of wind speed, direction, and wind power at 20 m above the surface for 65 Navy facilities. In addition, we derived the transmissivity of the atmosphere, diffuse radiation fraction, cloud cover and seasonal energy potential for a zenith facing surface with unobstructed horizon for each installation location based on the results of a broadband radiative transfer model and our cloud database based on 17-years of GOES data. Our analysis was incorporated in a GIS framework in combination with additional infrastructure data that enabled a synergistic resource assessment based on the combination of climatological and engineering factors.

  16. Cost-effectiveness of solar energy in energy-efficient buildings; Kosten und Nutzen von Solarenergie in energieeffizienten Bauten

    Kessler, S.; Iten, R.; Vettori, A. [Infras, Zuerich (Switzerland); Haller, A.; Ochs, M. [Ernst Schweizer AG, Hedingen (Switzerland); Keller, L. [Bureau d' Etudes Keller-Burnier, Lavigny (Switzerland)

    2005-07-01

    This report for the Swiss Federal Office of Energy (SFOE) presents the results of a study that examined the potentials and restraints with respect to the use of solar energy in the new construction and refurbishment of residential buildings in Switzerland. The method used is based on a 'learning-curve' technique. The first part of the report deals with the development of prices for solar-collector installations from 1990 until now. The second part deals with today's costs and future developments up to the year 2030. A reference building is used as the basis for the comparison of eight system variants. A further eight variants combine solar technology with traditional heating installations such as oil, gas and wood boilers and heat-pumps. Scenarios for the market situation for solar energy in 2030 are discussed.

  17. Horn installed in CNGS tunnel

    Maximilien Brice

    2005-01-01

    The horn is installed for the CERN Neutrinos to Gran Sasso (CNGS) project. Protons collide with a graphite target producing charged particles that are focussed by the magnetic field in the horn. These particles will then pass into a decay tube where they decay into neutrinos, which travel towards a detector at Gran Sasso 732 km away in Italy.

  18. Installation tests for BERSAFE 88

    Bamfield, R.D.; Haigh, R.

    1989-02-01

    A set of ten test problems for each of the four BERSAFE stress analysis programs is provided. These problems along with this report, which forms part of the BERSAFE 88 documentation, constitute a test of the customers' BERSAFE installation. On running the problems and attaining results identical to those presented here, the customer should have some confidence that his system is operating correctly. (author)

  19. YB0 SERVICES INSTALLATION COMPLETED

    The beauty of the completed YB0 was briefly visible at P5 as preparations continue for Tracker installation. A tremendous effort, lasting 7 months and involving more than 100 workers on the busiest days, resulted in 5700 electrical cables, 780 optical cables with 65k fibre channels, and 550 pipes laid on YB0 for HB, EB and Tracker.

  20. A techno-economic assessment of grid connected photovoltaic system for hospital building in Malaysia

    Mat Isa, Normazlina; Tan, Chee Wei; Yatim, AHM

    2017-07-01

    Conventionally, electricity in hospital building are supplied by the utility grid which uses mix fuel including coal and gas. Due to enhancement in renewable technology, many building shall moving forward to install their own PV panel along with the grid to employ the advantages of the renewable energy. This paper present an analysis of grid connected photovoltaic (GCPV) system for hospital building in Malaysia. A discussion is emphasized on the economic analysis based on Levelized Cost of Energy (LCOE) and total Net Present Post (TNPC) in regards with the annual interest rate. The analysis is performed using Hybrid Optimization Model for Electric Renewables (HOMER) software which give optimization and sensitivity analysis result. An optimization result followed by the sensitivity analysis also being discuss in this article thus the impact of the grid connected PV system has be evaluated. In addition, the benefit from Net Metering (NeM) mechanism also discussed.

  1. 46 CFR 121.240 - Gas systems.

    2010-10-01

    ... gas (LPG) and compressed natural gas (CNG) must meet the following requirements: (a) The design, installation and testing of each LPG system must meet ABYC A-1, “Marine Liquefied Petroleum Gas (LPG) Systems... 46 Shipping 4 2010-10-01 2010-10-01 false Gas systems. 121.240 Section 121.240 Shipping COAST...

  2. 30 CFR 57.4504 - Fan installations.

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fan installations. 57.4504 Section 57.4504... Control Installation/construction/maintenance § 57.4504 Fan installations. (a) Fan houses, fan bulkheads... of combustible materials, except installed wiring, ground and track support, headframes, and direct...

  3. Solar heating and domestic hot water system installed at North Dallas High School

    1980-01-01

    The solar energy system located at the North Dallas High School, Dallas, Texas is discussed. The system is designed as a retrofit in a three story with basement, concrete frame high school building. Extracts from the site files, specification references for solar modification to existing building heating and domestic hot water systems, drawings, installation, operation and maintenance instructions are included.

  4. Solar heating system installed at Jackson, Tennessee. Final report

    None

    1980-10-01

    The solar energy heating system installed at the Coca-Cola Bottling Works in Jackson, Tennessee is described. The system consists of 9480 square feet of Owens-Illinois evacuated tubular solar collectors with attached specular cylindrical reflectors and will provide space heating for the 70,000 square foot production building in the winter, and hot water for the bottle washing equipment the remainder of the year. Component specifications and engineering drawings are included. (WHK)

  5. Software for simulation of nuclear simulation of nuclear installations

    Castaneda, J.O.; Ramos, L.M.; Arjona, O.; Rodriguez, L.

    1993-01-01

    The software is an instrument to build conceptual-type simulators of low, medium and full scale for used in nuclear installations. The system is composed by composed by two basic modules: one for the edition and the other for the simulation. The first one allows to prepare the information to simulate: mathematical model, technological design (fundamentally, operation board or mnemotechnical design), parameters to be shown, failures to be simulated

  6. Statement of nuclear incidents at nuclear installations: first quarter 1994

    1994-06-01

    As a requirement of the 1974 Health and Safety at Work Act, the United Kingdom Health and Safety Inspectorate is required to publish reports of nuclear incidents at nuclear installations. This report covers the period 1st January to 31st March 1994. Two incidents are reported for Dungeness A Power Station, one at the Amersham International building on site at Harwell Laboratory, one at AEA Technology's Windscale Plant and one at British Nuclear Fuels Limited's Sellafield site. (UK)

  7. Last End Cap Toroid installation : The Pharaonic enterprise

    Arnaud Foussat

    After the successful and impressive transport feat from Building 191 to Point 1 was carried out by the Friderici crew on 28th June, the second and last Toroid End Cap, ECT-C, was transferred into the surface building, SX1, on 2nd July. The ECT-C was installed in the ATLAS cavern on the C-side on 12th July. As the person responsible for the project, in my opinion, one of the crucial points of this project was to design all the tooling and installation sequences taking into account the building infrastructure dimensional constraints. View of the ECT installation tooling and preparation for the ECT-C descent into the ATLAS 80m-shaft by the ATLAS magnet group and DBS teams. The movement of the 240-ton magnet and 12-m diameter toroid end-cap was achieved in collaboration with SCALES, a subcontractor company, using a hydraulic gantry able to lower the ECT inside the shaft by 5m below the floor level . This allowed the DBS team to attach the end-cap with the 2 x 140 tons overhead crane and lower it onto the c...

  8. Photovoltaic building blocks

    Hanberg, Peter Jesper; Jørgensen, Anders Michael

    2014-01-01

    efficiency of about 15% for commercial Silicon solar cells there is still much to gain. DTU Danchip provides research facilities, equipment and expertise for the building blocks that comprises fabricating the efficient solar cell. In order to get more of the sun light into the device we provide thin film......Photovoltaics (PV), better known as solar cells, are now a common day sight on many rooftops in Denmark.The installed capacity of PV systems worldwide is growing exponentially1 and is the third most importantrenewable energy source today. The cost of PV is decreasing fast with ~10%/year but to make...... it directcompetitive with fossil energy sources a further reduction is needed. By increasing the efficiency of the solar cells one gain an advantage through the whole chain of cost. So that per produced Watt of power less material is spent, installation costs are lower, less area is used etc. With an average...

  9. The installation of helium auxiliary systems in HTGR

    Qin Zhenya; Fu Xiaodong

    1993-01-01

    The inert gas Helium was chosen as reactor coolant in high temperature gas coolant reactor, therefore a set of Special and uncomplex helium auxiliary systems will be installed, the safe operation of HTR-10 can be safeguarded. It does not effect the inherent safety of HTR-10 MW if any one of all those systems were damaged during operation condition. This article introduces the design function and the system principle of all helium auxiliary systems to be installed in HTR-10. Those systems include: helium purification and its regeneration system, helium supply and storage system, pressure control and release system of primary system, dump system for helium auxiliary system and fuel handling, gaseous waste storage system, water extraction system for helium auxiliary systems and evacuation system for primary system

  10. Monitoring-based HVAC commissioning of an existing office building for energy efficiency

    Wang, Liping; Greenberg, Steve; Fiegel, John; Rubalcava, Alma; Earni, Shankar; Pang, Xiufeng; Yin, Rongxin; Woodworth, Spencer; Hernandez-Maldonado, Jorge

    2013-01-01

    Highlights: ► Demonstrated monitoring-based HVAC commissioning using an existing office building. ► Diagnosed various types of faulty operation in the HVAC system by trend data analyses. ► Identified a list of energy saving measures for the HVAC system. ► Quantified energy saving potential for each commissioning measure using calibrated energy simulation model. ► Achieved an actual energy saving of 10% after the implementations of cost-effective measures. -- Abstract: The performance of Heating, Ventilation and Air Conditioning (HVAC) systems may fail to satisfy design expectations due to improper equipment installation, equipment degradation, sensor failures, or incorrect control sequences. Commissioning identifies and implements cost-effective operational and maintenance measures in buildings to bring them up to the design intent or optimum operation. An existing office building is used as a case study to demonstrate the process of commissioning. Building energy benchmarking tools are applied to evaluate the energy performance for screening opportunities at the whole building level. A large natural gas saving potential was indicated by the building benchmarking results. Faulty operations in the HVAC systems, such as improper operations of air-side economizers, simultaneous heating and cooling, and ineffective optimal start, were identified through trend data analyses and functional testing. The energy saving potential for each commissioning measure is quantified with a calibrated building simulation model. An actual energy saving of 10% was realized after the implementations of cost-effective measures.

  11. Solar heating, cooling, and domestic hot water system installed at Kaw Valley State Bank and Trust Company, Topeka, Kansas

    1980-01-01

    The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.

  12. Physical protection of nuclear installations

    Toepfer, K.

    1989-01-01

    This contribution investigates the possible danger and the legal basis of physical protection and explains the current, integrated system provided for, as well as the underlying possible scenarios of an assault: (1) by a violent crowd of aggressors outside the installation, (2) by a small group of aggressors outside the installation, (3) by a person allowed to enter (internal assault). The physical protection system supplements the internal safety measures to enhance protection against hypothetical and possible acts of terrorism or other criminal assault. The system covers external and internal controlled areas, access monitoring, physical protection control room and service, security checks of the personnel, and activities to disclose sabotage. Some reflections on the problem field between security controls and the constitutional state conclude this contribution. (orig./HSCH) [de

  13. The dismantling of nuclear installations

    Lacoste, A.C.; Duthe, M.; Mignon, H.; Lambert, F.; Pradel, Ph.; Hillewaere, J.P.; Dupre la Tour, St.; Mandil, C.; Weil, L.; Eickelpasch, N.; Finsterwalder, L.

    1997-01-01

    for nuclear installations, the dismantling is an important part of their exploitation. The technology of dismantling is existing and to get a benefit from the radioactive decay, it seems more easy for operating company such E.D.F. to wait for fifty years before dismantling. But in order to get the knowledge of this operation, the Safety Authority wanted to devote this issue of 'Controle'to the dismantling method. This issue includes: the legal aspects, the risks assessment, the dismantling policy at E.D.F., the site of Brennilis (first French experience of dismantling), the dismantling techniques, the first dismantling of a fuel reprocessing plant, comparison with classical installations, economic aspect, some German experiences, the cleansing of the american site of Handford. (N.C.)

  14. ATLAS Software Installation on Supercomputers

    Undrus, Alexander; The ATLAS collaboration

    2018-01-01

    PowerPC and high performance computers (HPC) are important resources for computing in the ATLAS experiment. The future LHC data processing will require more resources than Grid computing, currently using approximately 100,000 cores at well over 100 sites, can provide. Supercomputers are extremely powerful as they use resources of hundreds of thousands CPUs joined together. However their architectures have different instruction sets. ATLAS binary software distributions for x86 chipsets do not fit these architectures, as emulation of these chipsets results in huge performance loss. This presentation describes the methodology of ATLAS software installation from source code on supercomputers. The installation procedure includes downloading the ATLAS code base as well as the source of about 50 external packages, such as ROOT and Geant4, followed by compilation, and rigorous unit and integration testing. The presentation reports the application of this procedure at Titan HPC and Summit PowerPC at Oak Ridge Computin...

  15. Environmental assessment [of nuclear installations

    Townsley, M.

    1989-01-01

    The European Community has introduced a directive which instructs that for all projects likely to have a significant effect on the environment consent should only be given after a rigorous assessment of such effects has been carried out and presented as an environmental statement. Projects requiring environmental assessment include nuclear power stations, any thermal power station over 300MW, any radioactive waste storage or disposal facility, any installation which produces electricity, power lines, installations for fuel production, fuel reprocessing, radioactive waste processing and fuel enrichment. The statement must include a description of the likely effects, direct and indirect, on the environment of the development, with reference to human beings, flora, fauna, soil, water, air, climate, landscape, interactions of two or more of these, material assets and cultural heritage. Measures to avoid or remedy the impact must be included. (U.K.)

  16. Use of thermal desorption gas chromatography-olfactometry/mass spectrometry for the comparison of identified and unidentified odor active compounds emitted from building products containing linseed oil

    Clausen, P. A.; Knudsen, Henrik Nellemose; Larsen, K.

    2008-01-01

    The emission of odor active volatile organic compounds (VOCs) from a floor oil based on linseed oil, the linseed oil itself and a low-odor linseed oil was investigated by thermal desorption gas chromatography combined with olfactometry and mass spectrometry (TD-GC-O/MS). The oils were applied...... to filters and conditioned in the micro emission cell, FLEC, for 1-3 days at ambient temperature, an air exchange rate of 26.9 h-1 and a 30% relative humidity. These conditions resulted in dynamic headspace concentrations and composition of the odor active VOCs that may be similar to real indoor setting...

  17. Quality assurance in nuclear installations

    Torres M, Nelson.

    1985-08-01

    It has been proven that the bad quality of products, equipment, installations, and services is not due to the lack of tests, experiments and verifications. The main causes are associated with insufficient organization of the activities that have influence on the quality. The garantee of quality is conceptualized as an appropriate instrument composed of normalized criteria initially in advanced technologies. Such as nuclear science and aerospace technology. However, with the appropriate modifications it can be applied to conventional technologies

  18. Method of installing well conductors

    Houser, D.M.

    1991-01-01

    This patent describes a method of installing a well conductor in a marine environment. It comprises sealing a well conductor with a watertight plug; submerging the conductor from an elevated platform; adding additional conductor lengths to the conductor as needed thereby forming a conductor string; adjusting the buoyancy of the string to control the lowering of the string to the sea floor; and drilling through the plug after the conductor string has achieved the desired penetration depth

  19. Seismic evaluation of nuclear installations

    Mattar Neto, Miguel

    1997-01-01

    Some considerations regarding extreme external events, natural or man-induce, such as earthquakes, floods, air crashes, etc, shall be done for nuclear facilities to minimizing the potential impact of the installation on the public and the environment. In this paper the main aspects of the seismic evaluation of nuclear facilities (except the nuclear power reactors) will be presented based on different codes and standards. (author). 7 refs., 2 tabs

  20. Mounting clips for panel installation

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  1. Building America

    Brad Oberg

    2010-12-31

    IBACOS researched the constructability and viability issues of using high performance windows as one component of a larger approach to building houses that achieve the Building America 70% energy savings target.

  2. Building calculations

    Jensen, Bjarne Christian; Hansen, Svend Ole

    Textbook on design of large panel building including rules on robustness and a method for producing the Statical documentattion......Textbook on design of large panel building including rules on robustness and a method for producing the Statical documentattion...

  3. Installed capacity in New York

    Charlton, J.

    2006-01-01

    This presentation discussed capacity issues related to the New York Independent System Operator (NYISO). The NYISO's market volume was approximately $11 billion in 2005, and it was responsible for providing 32,075 MW of electricity at peak load to its users. Regulatory uncertainty is currently discouraging investment in new generating resources. All load serving entities are required to contract for sufficient capacity in order to meet their capacity obligations. Market participants currently determine capacity and energy revenues. The NYISO market allows suppliers to recover variable costs for providing ancillary services, and the economic value of the revenue source governs decisions made in the wholesale electricity market. The installed capacity market was designed as a spot auction deficiency auction. Phased-in demand curves are used to modify the installed capacity market's design. A sloped demand curve mechanism is used to value capacity above the minimum requirement for both reliability and competition. Participation in the day-ahead market enhances competition and exerts downward pressure on energy and ancillary service market prices. It was concluded that the market structures and design features of the installed capacity markets recognize the need for system reliability in addition to encouraging robust competition and recognizing energy price caps and regulatory oversights. tabs., figs

  4. Leukaemia near british nuclear installations

    Hubert, D.

    1991-01-01

    An excess of childhood leukaemia has been seen near some British nuclear installations, especially near the Sellafield reprocessing plant. The same result was found in a more general study including a large number of nuclear sites. Similar studies made in USA, Canada and France have been negative. Moreover, epidemiological studies made in England have discovered other childhood leukaemia clusters in areas far from nuclear facilities, and especially near potential sites of nuclear installations. Several explanations are suggested but no definite conclusion is yet possible. Doses from radioactive releases seem to be too low to account for the additional deaths from leukaemia by environmental contamination. A virus activation, which might be associated with population influx into rural isolated areas, has been considered. The hypothesis of genetic mutation induced by ionising radiation in the fathers of children with leukaemia has been made because a higher risk of leukaemia was observed for children of fathers employed at Sellafield. No firm conclusion is possible considering the small number of observed cases and the lack of excess leukaemias in the offspring of Hiroshima and Nagasaki survivors. The possibility of internal contamination, chemicals or even radon is discussed as other causes. Studies in progress might allow to find an answer to the problem of leukaemia in the vicinity of British nuclear installations [fr

  5. Gas and Gas Pains

    ... to produce gas. Often, relatively simple changes in eating habits can lessen bothersome gas. Certain digestive system disorders, ... such as soda and beer, increase stomach gas. Eating habits, such as eating too quickly, drinking through a ...

  6. Analysis of energy economic renovation for historic wooden apartment buildings in cold climates

    Arumägi, Endrik; Kalamees, Targo

    2014-01-01

    Highlights: • Energy saving potential in historic wooden apartment buildings is up to 63%. • In historic wooden apartment buildings an economically viable energy saving level is 50%. • The largest energy saving potential lies in heat source and building service systems. • Of the building structures, insulation of the external wall has the highest potential. • New heating and ventilation systems must be installed to fulfill regulations limits. - Abstract: Buildings represent the largest sector of primary energy consumption and play a major role in saving energy and reducing greenhouse gas emissions. Our analysis of energy consumption and potential energy savings is based on field measurements, computer simulations and economic calculations. The average primary energy consumption (PE) of wooden apartment buildings was 331 kW h/(m 2 a) 83% higher than the limit 180 kW h/(m 2 a) set in national regulations for apartment buildings subject to major renovation. The studied buildings represent a high potential for energy savings. The renovation packages were compiled using different insulation measures, HVAC solutions and energy sources to achieve a 20–65% reduction of primary energy. For historic buildings, the renovation solutions that concentrate on the building envelope can be problematic due to the need to preserve cultural and architectural values. Our calculation results indicate that the cost optimal PE level is around 250 kW h/(m 2 a) and the point at which renovation packages recover expenses is around a PE level of 170 kW h/(m 2 a). In terms of the architectural appearance the point at which renovation packages recover expenses is around a PE level of 210 kW h/(m 2 a). We propose to set a different PE limit for historic wooden apartment buildings with an architectural appearance worth preserving

  7. Solar building

    Zhang, Luxin

    2014-01-01

    In my thesis I describe the utilization of solar energy and solar energy with building integration. In introduction it is also mentioned how the solar building works, trying to make more people understand and accept the solar building. The thesis introduces different types of solar heat collectors. I compared the difference two operation modes of solar water heating system and created examples of solar water system selection. I also introduced other solar building applications. It is conv...

  8. Building envelope

    Gibberd, Jeremy T

    2009-01-01

    Full Text Available for use in the building. This is done through photovoltaic and solar water heating panels and wind turbines. Ideally these are integrated in the design of the building envelope to improve the aesthetic quality of the building and minimise material... are naturally ventilated. Renewable energy The building envelope includes renewable energy generation such as photovoltaics, wind turbines and solar water heaters and 10% of the building’s energy requirements are generated from these sources. Views All...

  9. Model of the containment building of Almaraz NPP and the system of recombiners PARs, with the GOTHIC code, for the study of the diffusion of combustible gases

    Garcia Gonzalez, M.; Huelamo, E.; Mazrtinez, M.; Perez, J. R.

    2014-01-01

    This paper presents the analysis of distribution of gases within the containment building carried out a simulation model with the code Thermo hydraulic GOTHIC, which has been evaluated based on passive autocatalytic recombiners gas control system. The model considers scenarios of severe accident with specific conditions that produce the most hydrogen generation rates. Intended to verify the effectiveness of the control system of gas expected to be installed in the Almaraz Nuclear power plant so that the number and location of recombiners equipment meets its function of preventing the formation of explosive atmospheres which impairs the integrity of the containment, reducing and limiting the concentration of combustible gases during the postulated accident. (Author)

  10. Auxiliary buildings

    Lakner, I.; Lestyan, E.

    1979-01-01

    The nuclear power station represents a complicated and a particular industrial project. Consequently, the design of the auxiliary buildings serving the power station (offices, kitchen, refreshment room, workshops, depots, water treatment plant building, boiler houses, etc.) requires more attention than usual. This chapter gives a short survey of the auxiliary buildings already completed and discusses the problems of their design, location and structure. (author)

  11. Building 2000

    Den Ouden, C.; Steemers, T.C.

    1992-01-01

    This is the first volume of Building 2000, a pilot project of the Commission's R and D-programme 'Solar Energy Applications to Buildings' with the purpose of encouraging the adoption of solar architecture in large buildings. In this first rich illustrated volume the results of the design studies illustrating passive solar architecture in buildings in the European Community are presented in particular for the building categories as mentioned in the subtitle. In a second volume, a similar series of studies is presented for the building categories: office buildings, public buildings and hotels and holiday complexes. Several Design Support Workshops were organized during the Building 2000 programme during which Building 2000 design teams could directly exchange ideas with the various design advice experts represented at these workshops. In the second part of the Building 2000 final report a summary of a selection of many reports is presented (15 papers), as produced by Design Support experts. Most of the design support activities resulted in changes of the various designs, as have been reported by the design teams in the brochures presented in the first part of this book. It is to be expected that design aids and simulation tools for passive solar options, daylighting concepts, comfort criteria etc., will be utilized more frequently in the future. This will result in a better exchange of information between the actual design practitioners and the European R and D community. This technology transfer will result in buildings with a higher quality with respect to energy and environmental issues

  12. Building 2000

    Den Ouden, C [EGM Engineering BV, Dordrecht (Netherlands); Steemers, T C [Commission of the European Communities, Brussels (Belgium)

    1992-01-01

    This is the first volume of Building 2000, a pilot project of the Commission's R and D-programme 'Solar Energy Applications to Buildings' with the purpose of encouraging the adoption of solar architecture in large buildings. In this first rich illustrated volume the results of the design studies illustrating passive solar architecture in buildings in the European Community are presented in particular for the building categories as mentioned in the subtitle. In a second volume, a similar series of studies is presented for the building categories: office buildings, public buildings and hotels and holiday complexes. Several Design Support Workshops were organized during the Building 2000 programme during which Building 2000 design teams could directly exchange ideas with the various design advice experts represented at these workshops. In the second part of the Building 2000 final report a summary of a selection of many reports is presented (15 papers), as produced by Design Support experts. Most of the design support activities resulted in changes of the various designs, as have been reported by the design teams in the brochures presented in the first part of this book. It is to be expected that design aids and simulation tools for passive solar options, daylighting concepts, comfort criteria etc., will be utilized more frequently in the future. This will result in a better exchange of information between the actual design practitioners and the European R and D community. This technology transfer will result in buildings with a higher quality with respect to energy and environmental issues.

  13. Installation of the backfill and plug test

    Gunnarsson, D.; Borgesson, L.; Hokmark, H.; Hohannesson, L.E.; Sanden, T.

    2003-01-01

    The Backfill and Plug Test is a full scale test of backfill material, backfilling technique and a tunnel plug. The main objectives of the Backfill and Plug Test are: - to develop and test different materials and compaction techniques for backfilling of tunnels excavated by blasting; - to test the function of the backfill and its interaction with the surrounding rock in a tunnel excavated by blasting; - to develop technique for building tunnel plugs and to test the function. The installation was made in the Swedish underground laboratory, Aspo HRL, during 1999. The inner part of the tunnel is not used for the test but was filled with drainage material. The test volume, which is about 28 m long, can be divided into the following three parts: - the inner part filled with backfill containing 30% bentonite; - the outer part filled with backfill without bentonite and bentonite blocks and pellets at the roof; - the plug. Permeable layers divide the test volume into 11 test sections. The permeable layers are used for increasing the water saturation rate in the backfill and for applying hydraulic gradients between the layers for studying the flow of water in the backfill and in the near field rock. The permeable layers were installed every 2.2 m and each layer is divided into three units in order to separately measure the flow close to the roof, in the central areas of the tunnel and close to the floor. The outer part ends with a wall of prefabricated concrete beams that were used for temporary support of the backfill during the casting of the plug. The upper volume close to the plug is filled with bentonite pellets and blocks consisting of 20% bentonite and 80% sand. The backfill is instrumented with 34 pore water pressure cells, 21 total pressure cells, 57 sensors for monitoring the water saturation and 13 gauges for measuring the local hydraulic conductivity. The water pressures in the permeable mats are measured in all sections. Four pressure cylinders, 2 in the roof

  14. Gas Tank for Cars

    Peter Lorenz

    2011-09-01

    Full Text Available In this work the development of a highly efficient pressure vessel for liquid petroleum gas (LPG in integral design is described. The pressure vessel can be customized in an optimal available installation space and thus means that the suitable for everyday use of existing modified cars or trucks can be increased.

  15. Pressure Build-up and Decay in Acid Gas Injection Operations in Reefs in the Zama Field, Canada, and Implications for CO2 Storage

    Pooladi-Darvish, M.; Hong, H.; Pooladi-Darvish, M.; Bachu, S.

    2011-01-01

    The objective of this paper is to examine reasons for pressure rise in the Zama X2X pool in northwestern Alberta, Canada, that was used for acid gas disposal, and whether subsequent pressure decay was a result of pressure dissipation into a larger aquifer. The Zama X2X pool, approximately 1 km 2 in size, is connected to four other nearby pools through a common underlying aquifer. Pressure analysis for all the pools indicates that they are in good hydraulic communication. Initial pressure in the Zama X2X pool was approximately 15 MPa. Pressure declined first during oil production, stabilizing at around 10 MPa in the early 1970's, after which started to increase such that it reached 26 MPa in 1986. Subsequently, pressure declined reaching 22 MPa by 1995 just prior to starting injection of acid gas (80% CO 2 and 20% H 2 S). The operator injected acid gas at lower rates and wellhead pressures than those licensed by the regulatory agency. Despite significant production of water and hydrocarbons, the pressure in the Zama X2X pool continued to be higher than the initial reservoir pressure by more than 5 MPa, such that disposal operations were suspended in late 1998. Oil production continued all this time until 2002. Numerical simulations using CMG-IMEM and corresponding sensitivity studies reported in this paper show that disposal of more than 1 million m 3 of water between 1970 and 1988 and again in 1992-1993 in the adjacent Zama YY pool, which is in good hydrodynamic communication with the Zama X2X pool through the aquifer below the oil column, is the main reason for the high pressures observed in the Zama X2X pool. Sensitivity studies indicate that pressure decay in the X2X pool was due to fluid production. The study indicates that while pressure rise has been caused by hydraulic communication between the X2X and YY pools through the common aquifer, the aquifer was not of large volume to allow dissipation of the pressure. In addition to the case study, the implications

  16. Analysis of volatile organic compounds released from the decay of surrogate human models simulating victims of collapsed buildings by thermal desorption-comprehensive two-dimensional gas chromatography-time of flight mass spectrometry.

    Agapiou, A; Zorba, E; Mikedi, K; McGregor, L; Spiliopoulou, C; Statheropoulos, M

    2015-07-09

    Field experiments were devised to mimic the entrapment conditions under the rubble of collapsed buildings aiming to investigate the evolution of volatile organic compounds (VOCs) during the early dead body decomposition stage. Three pig carcasses were placed inside concrete tunnels of a search and rescue (SAR) operational field terrain for simulating the entrapment environment after a building collapse. The experimental campaign employed both laboratory and on-site analytical methods running in parallel. The current work focuses only on the results of the laboratory method using thermal desorption coupled to comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (TD-GC×GC-TOF MS). The flow-modulated TD-GC×GC-TOF MS provided enhanced separation of the VOC profile and served as a reference method for the evaluation of the on-site analytical methods in the current experimental campaign. Bespoke software was used to deconvolve the VOC profile to extract as much information as possible into peak lists. In total, 288 unique VOCs were identified (i.e., not found in blank samples). The majority were aliphatics (172), aromatics (25) and nitrogen compounds (19), followed by ketones (17), esters (13), alcohols (12), aldehydes (11), sulfur (9), miscellaneous (8) and acid compounds (2). The TD-GC×GC-TOF MS proved to be a sensitive and powerful system for resolving the chemical puzzle of above-ground "scent of death". Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Gas Detection for Experiments

    Hay, D

    2001-01-01

    Flammable gases are often used in detectors for physics experiments. The storage, distribution and manipulation of such flammable gases present several safety hazards. As most flammable gases cannot be detected by human senses, specific well-placed gas detection systems must be installed. Following a request from the user group and in collaboration with CERN safety officers, risk analyses are performed. An external contractor, who needs to receive detailed user requirements from CERN, performs the installations. The contract is passed on a guaranteed results basis. Co-ordination between all the CERN groups and verification of the technical installation is done by ST/AA/AS. This paper describes and focuses on the structured methodology applied to implement such installations based on goal directed project management techniques (GDPM). This useful supervision tool suited to small to medium sized projects facilitates the task of co-ordinating numerous activities to achieve a completely functional system.

  18. Review of vibration effect during piling installation to adjacent structure

    Rahman, Nurul Aishah Abd; Musir, Adhilla Ainun; Dahalan, Nurol Huda; Ghani, Abdul Naser Abdul; Khalil, Muhamad Kasimi Abd

    2017-12-01

    Basically, many major structures across the world such as towers, high rise building, houses and bridges utilize pile as a support material. The use of pile is important to strengthen the structures. However, this has led to another problem to the nearest surrounding structures resulted from pile driving. As part of a construction work, unavoidable pile driving activity generates a vibration towards the surrounding structures if uncontrolled may cause damage to the adjacent structure. As the current construction works are frequently located in urban areas where the distance between the nearest building structures is not far, vibration may cause damage to nearby structures. Knowing which part of the building that is mostly affected by various vibration patterns from the impact of pile driving is crucial. Thus, it is very important to predict the impact of vibration during piling installation work. This paper reviews the vibrations generated by piling activity toward surrounding structures in terms sources of vibration, impact of piling installation, pile-soil interaction, and factors affecting the vibration impact of building as well as to study the parameters involved in vibration generation during piling works.

  19. State of gas exchange in recumbent and orthostatic positions and under physical load in healthy persons of varying age, sex and body build

    Glezer, G. A.; Charyyev, M.; Zilbert, N. L.

    1980-01-01

    Age effect on gas exchange was studied in the recumbent and orthostatic positions and under physical load. In the case of the older age group and for normal as compared with hypersthenic persons, oxygen consumption during rest and during moderate physical overload diminishes. When the vertical position is assumed oxygen consumption in persons of various age groups is distinctly increased, particularly in the elderly group. There is a reduction in the amount of oxygen consumption, oxygen pulse, recovery coefficient, and work efficiency under moderate overload. In persons over 50, physical labor induces a large oxygen requirement and a sharp rise in the level of lactic acid and the blood's lactate/pyruvate ratio. No distinct difference was noted in the amount of oxygen consumed during rest and during physical overload in men and women of the same physical development and age.

  20. Reproductive effects of the water-accommodated fraction of a natural gas condensate in the Indo-Pacific reef-building coral Pocillopora damicornis.

    Villanueva, R D; Yap, H T; Montaño, M N E

    2011-11-01

    Toxic effects of the water-accommodated fraction (WAF) of a natural gas condensate on the reproduction of the brooding coral Pocillopora damicornis were studied in short-term (24 h) laboratory experiments. Coral fragments were exposed to varying concentrations of condensate WAF during different reproductive phases: gametogenesis, early embryogenesis, and late embryogenesis (when nighttime planulation occurs). During gametogenesis, exposure to condensate WAF did not inhibit subsequent production of larvae. On the other hand, exposure to >25% WAF of gravid corals, at early and late embryogenesis, resulted in abortion and early release of larvae, respectively, with higher percentages of larvae expelled in fragments treated with higher concentrations of condensate WAF at least 3h after onset of exposure. Aborted larvae during early embryogenesis were 'premature', as they are of small size (0.06±0.03 mm³), low metamorphic competency (54%), and white in coloration, with a pale brown oral end (indicating low density of zooxanthellae). Those larvae released at the latter part of embryogenesis are bigger in size (0.22±0.08 mm³), possess 100% metamorphic competency, and are brown in coloration (high density of zooxanthellae). Aside from direct effects on reproduction, fragment mortality index was higher in samples exposed to higher concentrations of condensate WAF (>25%), hence lowering the number of potentially reproducing polyps. Altogether, exposure to >25% natural gas condensate WAF for at least 3h can potentially disrupt the replenishment of coral populations due to negative effects on reproduction and early life processes. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Impact of PID on industrial rooftop PV-installations

    Buerhop, Claudia; Fecher, Frank W.; Pickel, Tobias; Patel, Tirth; Zetzmann, Cornelia; Camus, Christian; Hauch, Jens; Brabec, Christoph J.

    2017-08-01

    Potential induced degradation (PID) causes severe damage and financial losses even in modern PV-installations. In Germany, approximately 19% of PV-installations suffer from PID and resulting power loss. This paper focuses on the impact of PID in real installations and how different evaluated time intervals influence the performance ratio (PR) and the determined degradation rate. The analysis focuses exemplarily on a 314 kWp PV-system in the Atlantic coastal climate. IR-imaging is used for identifying PID without operation interruption. Historic electric performance data are available from a monitoring system for several years on system level, string level as well as punctually measured module string IV- curves. The data sets are combined for understanding the PID behavior of this PV plant. The number of PID affected cells within a string varies strongly between 1 to 22% with the string position on the building complex. With increasing number of PID-affected cells the performance ratio decreases down to 60% for daily and monthly periods. Local differences in PID evolution rates are identified. An average PR-reduction of -3.65% per year is found for the PV-plant. On the string level the degradation rate varied up to 8.8% per year depending on the string position and the time period. The analysis reveals that PID generation and evolution in roof-top installations on industrial buildings with locally varying operation conditions can be fairly complex. The results yield that local operating conditions, e.g. ambient weather conditions as well as surrounding conditions on an industrial building, seem to have a dominating impact on the PID evolution rate.

  2. Radio-contaminant behaviour in the cover-gas space and the containment building of a sodium-cooled fast reactor in accident conditions

    Mathe, Emmanuel

    2014-01-01

    In the context of the Generation IV initiative, the consequences of a severe-accident (SA) in a sodium-cooled fast reactor must be studied. A SFR (Sodium cooled Fast Reactor) severe accident involves the disruption of the core by super-criticality involving the destruction of a certain number of fuel assemblies. Subsequently the interaction between hot fuel and liquid sodium can lead to a vapor explosion which could create a breach in the primary system. Some contaminated liquid sodium would thus be ejected into the containment building. In this situation, the evaluation of potential releases to the environment (the source term) must forecast the quantity and the chemical speciation of the radio-contaminants likely to be released from the containment building. One critical risk of a SA is the production of contaminated aerosols in the containment building by spray ejection of primary-system sodium. Being pyrophoric, the sodium droplets react with oxygen first oxidizing then burning, with significant heat of combustion. As well as evaluating the consequences of a pressure rise inside the containment, the evolution of the sodium must be assessed since not only is it activated and contaminated but, in oxide form, very toxic. Ultimately, the aerosols are the main radiological risk acting as the vector for radionuclide transport to the environment in the event of a problem with the confinement. These aerosols could evolve and interact with the FP (Fissile Products) and these interactions could modify the physical and chemical nature of the PF. We model a large part of the events that occur during a SA inside a SFR from the sodium spray fire to the reaction between sodium aerosols and PF (iodine). At first, we develop a numerical model (NATRAC) that simulates the sodium spray fire, calculates the temperature and the pressure inside the containment as well as the mass of aerosols produced during this kind of fire. The simulation has been validated with different

  3. Nuclear installations: decommissioning and dismantling

    Anon.

    1995-01-01

    This document is a compilation of seven talks given during the 1995 EUROFORUM conference about decommissioning and dismantling of Nuclear installations in the European Community. The first two papers give a detailed description of the legal, financial and regulatory framework of decommissioning and dismantling of nuclear facilities in the European Union and a review of the currently available decommissioning techniques for inventory, disassembly, decontamination, remote operations and management of wastes. Other papers describe some legal and technical aspects of reactor and plants dismantling in UK, Germany, Spain and France. (J.S.)

  4. Helium transfer line installation details.

    G. Perinic

    2007-01-01

    A particularity of the 32 m long four in one helium transfer line in between the cold box in USC55 and the cavern UX5 is the fact that the transfer line passes through a hole in the crane rail support beam. In order to ensure the alignment of the suspension rail in the interconnecting tunnel with the hole in the rail support as well as the connection points at both ends required precise measurements of the given geometries as well as the installation of a temporary target for the verification of the theoretical predictions.

  5. Rehyd development and installation report

    Schuch, R.L.; Woodall, H.N.

    1977-12-01

    Rehyd, a low-impedance, HYDRA-type, water transmission line for bremsstrahlung exposures, was installed on the north side of the REBA facility. Rehyd produces 300 kA beams of 1.2 MeV electrons with a pulse width of 170 ns. Nominal x-ray exposure dose capabilities of 7 cal/g and 20 to 25 kJ were realized thus far. A description is given of the specific design parameters and facility layouts including the unique features of the REBA Marx generator/Rehyd line energy-transfer system. Diode configurations, magnetic-field applications, and output measurements are also presented

  6. Not simply a pipe dream : new concept in pipelaying is helping to build one of Europe's major gas pipelines

    Anon.

    2010-07-15

    This article discussed Volvo Construction Equipment's new concept in pipelaying machinery and its use in building the Bunde-Etzel pipeline. The Volvo PL4611 can lower a 1-kilometre-long pipe at once using 10 Volvo pipelayers at the same time. Lowering and laying is the sole purpose of the Volvo machines, and they are accompanied by 10 Volvo EC290BNLC crawler excavators. The Volvo pipelayers differ from conventional side-boom track-type tractor pipelayers in that the boom can turn 360 degrees, providing greater flexibility, precision, and control for placing pipe. The PL4611 is based on the EC460C standard excavator hydraulic design, so it can be disassembled easily and transported quickly. By switching the boom for digging equipment, the PL4611 can be changed into an excavator. The boom is longer than a standard pipelayer, allowing the machine to sit back from the trench, lessening the risk of tipping. The boom is mounted inside the track frame, near the machine's central line, providing it with a higher lift capacity and greater stability. The standard fully enclosed Volvo Care Cab provides the operator with excellent visibility. The boom is asymmetrical, allowing the pipe to be seen at all times for placing loads safely and precisely. A standard Load Management System enables the operator to determine what can be lifted safely. The pipelayer also meets the highest emission standards. 3 figs.

  7. Proper Installation of Replacement Windows | Efficient Windows

    Collaborative Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring

  8. Performance evaluation of buried pipe installation.

    2010-05-01

    The purpose of this study is to determine the effects of geometric and mechanical parameters characterizing the soil structure interaction developed in a buried pipe installation located under roads/highways. The drainage pipes or culverts installed ...

  9. 14 CFR 171.159 - Installation requirements.

    2010-01-01

    ... Installation requirements. (a) The facility must be installed according to accepted good engineering practices... must have a reliable source of suitable primary power, either from a power distribution system or...

  10. Building 2000

    Den Ouden, C.; Steemers, T.C.

    1992-01-01

    This is the second volume of Building 2000, a pilot project of the Commission's R and D-programme 'Solar Energy Applications to Buildings' with the purpose of encouraging the adoption of solar architecture in large buildings. In this second rich illustrated volume the results of the design studies illustrating passive solar architecture in buildings in the European Community are presented in particular for the building categories as mentioned in the subtitle. In the first volume, a similar series of studies is presented for the building categories: schools, laboratories and universities, and sports and educational centres. Several Design Support Workshops were organized during the Building 2000 programme during which Building 2000 design teams could directly exchange ideas with the various design advice experts represented at these workshops. In the second part of the Building 2000 final report a summary of a selection of many reports is presented (11 papers), as produced by Design Support experts. Most of the design support activities resulted in changes of the various designs, as have been reported by the design teams in the brochures presented in the first part of this book. It is to be expected that design aids and simulation tools for passive solar options, daylighting concepts, comfort criteria etc., will be utilized more frequently in the future. This will result in a better exchange of information between the actual design practitioners and the European R and D community. This technology transfer will result in buildings with a higher quality with respect to energy and environmental issues

  11. Building 2000

    Den Ouden, C [EGM Engineering BV, Dordrecht (Netherlands); Steemers, T C [Commission of the European Communities, Brussels (Belgium)

    1992-01-01

    This is the second volume of Building 2000, a pilot project of the Commission's R and D-programme 'Solar Energy Applications to Buildings' with the purpose of encouraging the adoption of solar architecture in large buildings. In this second rich illustrated volume the results of the design studies illustrating passive solar architecture in buildings in the European Community are presented in particular for the building categories as mentioned in the subtitle. In the first volume, a similar series of studies is presented for the building categories: schools, laboratories and universities, and sports and educational centres. Several Design Support Workshops were organized during the Building 2000 programme during which Building 2000 design teams could directly exchange ideas with the various design advice experts represented at these workshops. In the second part of the Building 2000 final report a summary of a selection of many reports is presented (11 papers), as produced by Design Support experts. Most of the design support activities resulted in changes of the various designs, as have been reported by the design teams in the brochures presented in the first part of this book. It is to be expected that design aids and simulation tools for passive solar options, daylighting concepts, comfort criteria etc., will be utilized more frequently in the future. This will result in a better exchange of information between the actual design practitioners and the European R and D community. This technology transfer will result in buildings with a higher quality with respect to energy and environmental issues.

  12. Lifetime environmental impact of buildings

    Mequignon, Marc

    2014-01-01

    This work discusses the impact of the life of buildings on? sustainable development methods.?The study of the lifespan of the building is used to assess and?manage the environmental impacts associated?with all the stages of a product's life, from raw material extraction?through to repair, maintenance and?? 'end of life' scenarios. While several papers have discussed thegreenhouse gas emissions of buildings,?less research has been done on how these are affected by the lifespan?of the building. This book serves to?highlight the pertinence of this factor and contributes to providing?new ideas on

  13. Radon Protection in the Technical Building Code

    Frutos, B.; Garcia, J. P.; Martin, J. L.; Olaya, M.; Serrano, J I.; Suarez, E.; Fernandez, J. A.; Rodrigo, F.

    2003-01-01

    Building construction in areas with high radon gas contamination in land requires the incorporation of certain measures in order to prevent the accumulation of this gas on the inside of buildings. These measures should be considered primarily in the design and construction phases and should take the area of the country into consideration where the construction will take place depending on the potential risk of radon entrance. Within the Technical Building Code, radon protection has been considered through general classification of the country and specific areas where building construction is to take place, in different risk categories and in the introduction of building techniques appropriate for each area. (Author) 17 refs

  14. Information from the installation service

    GS Department

    2010-01-01

    The French customs office moves out from Prévessin (building 904) to Ferney-Voltaire on January 20th-21st-22nd. For this reason the customs office will remain closed from Wednesday 20th to Friday 22nd January included. The service will open at the French customs office in Ferney-Voltaire on Monday January 25th.

  15. Installation of stationary battery plants

    Nowak, K

    1977-01-01

    The author discusses the problems encountered in designing battery rooms and charging stations. The VDE 0510 rule is not sufficient. Additional Laender regulations (regulations concerning electrical operating rooms) are not uniform. It is therefore necessary for planners, builders, owners, and building authorities to establish a common standard.

  16. Vacuum Insulation Panels Applied in Building Constructions

    Tenpierik, M.J.

    2010-01-01

    Due to sustainability and due to international treaties, it is desired and required to reduce greenhouse gas emissions drastically. One contributor to these emissions is the burning of fossil fuels for generating power and electricity to be used in and for buildings. Buildings and building-related

  17. Recovery of krypton-85 from dissolver off-gas streams

    Law, J.P.; Lamb, K.M.

    1988-01-01

    The Rare Gas Plant at the Idaho Chemical Processing Plant Recovers fission product krypton and xenon from dissolver off gas streams. Recently the system was upgraded to allow processing of hydrogen rich dissolver off-gas streams. A trickle bed hydrogen recombiner was installed and tested. The Rare Gas Plant can now safely process gas streams containing up to 80% hydrogen

  18. Facile Synthesis of a Hydroxyl-Functionalized Tröger’s Base Diamine: A New Building Block for High-Performance Polyimide Gas Separation Membranes

    Ma, Xiaohua

    2017-12-04

    Two intrinsically microporous polyimides (PIM-PIs) were synthesized by the polycondensation reaction of 4,4′-(hexafluoroisopropylidene)diphthalic anhydride (6FDA) and 3,3,3′,3′-tetramethylspirobisindane-6,7,6′,7′-tetracarboxylic dianhydride (SBI) with a newly designed o-hydroxyl-functionalized Tröger’s base diamine, 1,7-diamino-6H,12H-5,11-methanodibenzo[1,5]diazocine-2,8-diol (HTB). Both amorphous PIM-PIs were soluble in aprotic solvents and showed excellent thermal stability with onset decomposition temperature of ∼380 °C. SBI-HTB displayed a higher CO2 permeability (466 vs 67 barrer) than 6FDA-HTB but a significantly lower selectivity for CO2/CH4 (29 vs 73), H2/CH4 (29 vs 181), O2/N2 (4.6 vs 6.0), and N2/CH4 (1 vs 2.5). 6FDA-HTB displayed the highest gas-pair permselectivity values of all reported OH-functionalized PIM-PIs to date. The high permselectivity of 6FDA-HTB resulted primarily from exceptional diffusion selectivity due to strong size-sieving properties caused by hydrogen bonding between the proton of the hydroxyl group and the nitrogen atoms in the tertiary amine of the Tröger’s base (O–H···N).

  19. Procedure for qualification of electric equipment installed in containments for pressurized water reactors subject to accident conditions

    1991-11-01

    This generic norm is usable for electrical equipment installed in containment building of PWR subject to accidental conditions. She defines the qualification methods and the general rules usable for the test specifications of qualification for these materials

  20. Fuel followed control rod installation at AFRRI

    Moore, Mark; Owens, Chris; Forsbacka, Matt

    1992-01-01

    Fuel Followed Control Rods (FFCRs) were installed at the Armed Forces Radiobiology Research Institute's 1 MW TRIGA Reactor. The procedures for obtaining, shipping, and installing the FFCRs is described. As part of the FFCR installation, the transient rod drive was relocated. Core performance due to the addition of the fuel followed control rods is discussed. (author)

  1. Flat-plate solar collector - installation package

    1978-01-01

    Package includes installation, operation and maintenance manual for collector, analysis of safety hazards, special handling instructions, materials list, installation drawings, and warranty and certification statement. Manual includes instructions for roof preparation and for preparing collector for installation. Several pages are devoted to major and minor repairs.

  2. 47 CFR 22.383 - In-building radiation systems.

    2010-10-01

    ... MOBILE SERVICES Operational and Technical Requirements Technical Requirements § 22.383 In-building radiation systems. Licensees may install and operate in-building radiation systems without applying for... 47 Telecommunication 2 2010-10-01 2010-10-01 false In-building radiation systems. 22.383 Section...

  3. Laboratory Building

    Herrera, Joshua M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-03-01

    This report is an analysis of the means of egress and life safety requirements for the laboratory building. The building is located at Sandia National Laboratories (SNL) in Albuquerque, NM. The report includes a prescriptive-based analysis as well as a performance-based analysis. Following the analysis are appendices which contain maps of the laboratory building used throughout the analysis. The top of all the maps is assumed to be north.

  4. Thermo Active Building Systems – Using Building Mass To Heat and Cool

    Olesen, Bjarne W.

    2014-01-01

    , Austria, Netherlands, etc.), this type of system has been installed in a significant number of new office buildings since the late 1990s. The trend is spreading to other parts of the world (the rest of Europe, North America and Asia). Thermo active building systems (TABS) are primarily used for cooling...

  5. Water and power installation for Lanzarote (Canary Islands) Spain

    Krebs, F.

    1977-03-01

    Water producing and electrical generating facilities had to be increased on the Spanish Canary Island of Lanzarote for it to develop beyond its 1972 status. The Ministry of Public Works, prepared specifications for a turnkey installation of two 2500 M/sup 3//D desalting plants and a 5 MW (net) generating system. In 1973 through international competition Babcock and Wilcox, Espanola won a contract to build the installation. In December 1975 the construction of the project was completed. In early January 1976 the first line was producing 103% of the rated production at a thermal efficiency of 120% of the rated value. The second line was modified to operate at a reduced maximum brine temperature and commissioned. This plant was brought to full production which was 115% of the rated production in 2/sup 1///sub 2/ days. Problems and delays during the commissioning, were minimal. A 5 days performance test of the installation was run. During this test the water production was 111/sup 1///sub 2/% of the rated value at a specific energy consumption of 93% of the rated value while the maximum brine temperature was maintained 6/sup 0/C less than the design value. The high performances were achieved because the plants were well designed and built and properly commissioned. During the first 4/sup 1///sub 2/ months that the owner operated the installation it provided water and power as demanded. During that time the average plant production was 107% of the rated capacity.

  6. Statement of nuclear incidents at nuclear installations

    2002-01-01

    The Health and Safety Executive (HSE) presents the statement of nuclear incidents at nuclear installations published under the Health and Safety Commission's powers derived from section 11 of the Health and Safety at Work, etc. Act 1974. INCIDENT 02/4/1. Harwell (United Kingdom Atomic Energy Authority) On 6 November 2002 during operations in a glove box in B220, the over pressure alarm sounded. The operators evacuated and shortly afterwards the airborne activity monitors also sounded. The building emergency arrangements for airborne activity alarms was initiated to ascertain the source and to manage the operations. An investigation by UKAEA confirmed that a release of Americium 241 into the working area had occurred at a quantity in excess of Schedule 8 column 4 of the Ionising Radiations Regulations 1999 (IRRs). A number of personnel have received intakes including the two operators and the health physics personnel who attended the event. The highest dose (up to 6 mSv.) was received by the Health Physics charge hand. UKAEA placed an embargo on the use of similar systems and have completed their own management investigation and produced an internal report. It concludes that the likely cause of the event was over-pressurisation of the vacuum equipment used in the process. The report also highlights improvements required to the ventilation system in the laboratory and adjoining areas. An action plan has been developed for this work and progress is being made. NIl has followed the UKAEA investigation and carried out its own study including a visit by a ventilation specialist. This has confirmed the problems with the ventilation system. It is a complex issue that may have a wider impact across the building. A letter has been sent to UKAEA detailing a series of short-term requirements and the need to review implications and produce a longer-term action plan. UKAEA is cooperating fully with these requirements. INCIDENT 02/4/2. Dounreay (United Kingdom Atomic Energy

  7. Energy transition and security: which voluntary codes? Energy efficiency: IEA, IEC and ISO dialogue. The European Commission's safety, solidarity and efficiency measures. Securing natural gas supplies and favoring cogeneration. Less energy consuming buildings: rework of the energy efficiency directive. Energy efficiency inside buildings: GDF Suez report

    Tourneur, J.C.

    2009-01-01

    This dossier gathers a series of short articles about energy security and efficiency in a context of policy transition. The first paper deals with the use of international standards to promote energy efficiency thanks to efficient public policies and private sector actions. This was the main topic of the mixed workshop organized by the International electrotechnics Commission (IEC) in spring 2009. The second paper presents the new strategic analysis of the European commission in the domain of energy which stresses on the '20-20-20' climate change proposals approved in December 2008. A new European action plan for energy security and solidarity defines 5 domains requiring an extra action to warrant a sustainable energy supply. The commission is also examining the challenges that Europe will have to face between 2020 and 2050. The third article treats of the security of natural gas supplies which represents a quarter of the European Union (EU) energy mix. The supply crises susceptible to occur may have serious economic and social consequences. Therefore, the EU must be prepared to warrant its security of supplies. Cogeneration allows the EU to stay close to its energy goals. Buildings play a key role in the realisation of the EU's energy saving objectives and fight against climate change. The new directive on buildings energy efficiency (2002/91/CE) will allow to exploit this potential of saving and to stimulate sustainable investment and employment as well. Finally, the publication of the second WBCSD (World business council for sustainable development) international report on buildings energy efficiency has led GDF Suez utility to reaffirm its commitment in favour of energy saving and efficiency. (J.S.)

  8. Completed installations and the individual commissioning of the KSTAR MG system

    Kim, Chang-Hwan, E-mail: kch2004@nfri.re.kr [National Fusion Research Institute, 169-148 Gwahangno, Yusung-gu, Daejeon 305-333 (Korea, Republic of); Eom, Dae-young; Lee, Woo-Jin; Kong, Jong-Dea; Joung, Nam-Young; Kim, Yang-Soo; Kwon, Myeun [National Fusion Research Institute, 169-148 Gwahangno, Yusung-gu, Daejeon 305-333 (Korea, Republic of); Jang, Eun; Han, Chul-Woo; Lee, Sel-Ki; Kim, Gwang-Seon; Maeng, Jae-Hoon [Vitzrotech Co., Ltd, 605-2 Seonggok-dong, Danwon-gu, Ansan, Gyeonggi-do 425-833 (Korea, Republic of)

    2014-04-15

    Highlights: • All components of the MG system were made from each professional supplier and installed completely in the NFRI site. • The building and the overhead crane which need to install the MG system, were built in two sections. One is for the bearing, rotor and stator and the other section is for the VVVF and excitation system. • The dummy coil testing will commence in July 2013 and the comprehensive performance test of MG will be tested from August when the MPS commissioning is processing with superconducting coil. - Abstract: Peak power of 200 MVA is required in order to achieve the goal within a long pulse scenario for the final operation of the Korean Superconducting Tokamak Advanced Research (KSTAR). The available grid power is only 100 MVA at the National Fusion Research Institute (NFRI) site. Motor generator (MG) was considered as a method of resolving such problems. The design of the KSTAR MG system was completed in July 2010 and individual devices were produced by relevant manufacturers. The installation of individual devices was completed in December 2012. Specifically, the stator and rotor were assembled at the site due to their large size and weight. The bearings, variable voltage variable frequency (VVVF) and excitation systems were transported and installed on site after being manufactured externally. The building used for MG installation was built in 2011. With the building designed for ease of installation, an overhead crane was designed to allow access to the loading bay. In this paper, we discuss the installation of the MG system and the construction of the building suitable for installation of individual devices. In addition, performance on the test results of individual devices is also discussed.

  9. Solar hot water system installed at Las Vegas, Nevada. Final report

    None

    1981-01-01

    The solar hot water system installed at LaQuinta Motor Inn Inc., at Las Vegas, Nevada is described. The Inn is a three-story building with a flat roof for installation of the solar panels. The system consists of 1200 square feet of liquid flat plate collectors, a 2500 gallon insulated vertical steel storage tank, two heat exchangers and pumps and controls. The system was designed to supply approximately 74 percent of the total hot water load.

  10. Installation of the LHC experimental insertions

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the low-beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  11. INSTALLATION OF THE LHC EXPERIMENTAL INSERTIONS

    Bartolome-Jimenez, S

    2004-01-01

    The installation of the LHC experimental insertions, and particularly the installation of the Low-Beta quadrupoles, raises many technical challenges due to the stringent alignment specifications and to the difficulty of access in very confined areas. The compact layout with many lattice elements, vacuum components, beam control instrumentation and the presence of shielding does not allow for any improvisation in the installation procedure. This paper reviews all the constraints that need to be taken into account when installing the experimental insertions. It describes the chronological sequence of installation and discusses the technical solutions that have been adopted.

  12. The effect of cleanliness control during installation work on the amount of accumulated dust in ducts of new HVAC installations.

    Holopainen, R; Tuomainen, M; Asikainen, V; Pasanen, P; Säteri, J; Seppänen, O

    2002-09-01

    The aim of this study was to evaluate the amount of dust in supply air ducts in recently installed ventilation systems. The samples for the determination of dust accumulation were collected from supply air ducts in 18 new buildings that have been constructed according to two different cleanliness control levels classified as category P1 (low oil residues and protected against contaminations) and category P2, as defined in the Classification of Indoor Climate, Construction and Building Materials. In the ducts installed according to the requirements of cleanliness category P1 the mean amount of accumulated dust was 0.9 g/m2 (0.4-2.9 g/m2), and in the ducts installed according to the cleanliness category P2 it was 2.3 g/m2 (1.2-4.9 g/m2). A significant difference was found in the mean amounts of dust between ducts of categories P1 and P2 (P < 0.008). The cleanliness control procedure in category P1 proved to be a useful and effective tool for preventing dust accumulation in new air ducts during the construction process. Additionally, the ducts without residual oil had lower amounts of accumulated dust indicating that the demand for oil free components in the cleanliness classification is reasonable.

  13. Indigenous Architecture for Expeditionary Installations

    2006-03-01

    engineers to choose from pre-established contract line items to custom-order buildings depending on the need. This process is quick and easy, often...extremely strong and capable of withstanding strong windstorms (Nabokov, 1989: 340). Like the Navajo, the Pima and Papago tribes also adapted their...CLTD values could not be found for the subject wall assemblies; therefore, a straight temperature difference was used. Furthermore, since the focus

  14. Wind profiler installed in Antarctica

    Balsley, B. B.; Carey, J.; Woodman, R. F.; Sarango, M.; Urbina, J.; Rodriguez, R.; Ragaini, E.

    A VHF (50 MHz) wind profiler was installed in Antarctica at the Peruvian Base “Machu Picchu” on King George Island from January 21 to 26. The wind profiler will provide a first look at atmospheric dynamics over the region.The profiler—the first of its kind in Antarctica—is a National Science Foundationsponsored cooperative project of the University of Colorado, the Geophysical Institute of Peru, the University of Piura (Peru), and the Peruvian Navy. This venture was also greatly facilitated by Peru's Comision Nacional de Asuntos Antartidos and Consejo Nacional de Ciencias y Tecnologia, with additional logis tics support provided by the Argentinean Navy and the Uruguayan Air Force.

  15. Problems of Technology of Energy-Saving Buildings and Their Impact on Energy Efficiency in Buildings

    Kwasnowski, Pawel; Fedorczak-Cisak, Malgorzata; Knap, Katarzyna

    2017-10-01

    Introduction of EPBD in legislation of the EU member states caused that buildings must meet very stringent requirements of thermal protection and energy efficiency. On the basis of EPBD provisions, EU Member States introduce standard of NZEB (Nearly Zero-Energy Buildings). Such activities cause a need for new, innovative materials and technologies, and new approaches to design, construction and retrofitting of buildings. Indispensable is the precise coordination of the design of structure and technical installations of building, which may be provided in an integrated design process in the system BIM. Good coordination and cooperation of all contractors during the construction phase is also necessary. The article presents the problems and the new methodology for the design, construction and use of energy efficient buildings in terms of energy saving technologies, including discussion of the significant impact of the automation of technical installations on the building energy efficiency.

  16. Energy efficiency to reduce residential electricity and natural gas use under climate change.

    Reyna, Janet L; Chester, Mikhail V

    2017-05-15

    Climate change could significantly affect consumer demand for energy in buildings, as changing temperatures may alter heating and cooling loads. Warming climates could also lead to the increased adoption and use of cooling technologies in buildings. We assess residential electricity and natural gas demand in Los Angeles, California under multiple climate change projections and investigate the potential for energy efficiency to offset increased demand. We calibrate residential energy use against metered data, accounting for differences in building materials and appliances. Under temperature increases, we find that without policy intervention, residential electricity demand could increase by as much as 41-87% between 2020 and 2060. However, aggressive policies aimed at upgrading heating/cooling systems and appliances could result in electricity use increases as low as 28%, potentially avoiding the installation of new generation capacity. We therefore recommend aggressive energy efficiency, in combination with low-carbon generation sources, to offset projected increases in residential energy demand.

  17. Building a capacity building manual

    Clinton, DD

    2010-02-01

    Full Text Available Organizations 2010 Building a capacity building manual Daniel D. Clinton, Jr., P.E., F.NSPE Chair, WFEO Capacity Building Committee Dr Andrew Cleland, FIPENZ, Chief Executive, IPENZ, NZ Eng David Botha, FSAICE, Executive Director, SAICE, SA Dawit... 2010 Tertiary level University curricula Coaches and mentors Facilities EXCeeD Remuneration of Academics Experiential training Outreach to Students Students chapters Young members forum World Federation of Engineering Organizations 2010 Post...

  18. Quality assurance in the structural installations of nuclear power stations

    Schnellenbach, G.; Wrage, S.

    1985-01-01

    The concept of quality assurance distinguishes between self-monitoring of the design, manufacturing and executing firms and external monitoring by state institutions or by experts commissioned by them. The long-term control of structures is within the area of responsibility of the owner. This quality assurance concept is controlled in detail by statutes, which clearly define responsibilities. This structural engineering quality assurance system also forms the basis for the design, construction and utilization of structural installations of nuclear power stations; requirements emanating from the Atomic Energy Acts for the structural installations demand, however, to some extent a sharpening of self- and external monitoring. Therefore, today a quality concept has been developed for the important engineering safety-related buildings of nuclear power stations. This concept takes account of the strict requirements imposed and fulfils the requirement of KTA 1401. (orig.) [de

  19. Heritage plaza parking lots improvement project- Solar PV installation

    Hooks, Todd [Agua Caliente Indian Reservation, Palm Springs, CA (United States)

    2017-03-31

    The Agua Caliente Band of Cahuilla Indians (ACBCI or the “Tribe”) installed a 79.95 kW solar photovoltaic (PV) system to offset the energy usage costs of the Tribal Education and Family Services offices located at the Tribe's Heritage Plaza office building, 90I Tahquitz Way, Palm Springs, CA, 92262 (the "Project"). The installation of the Solar PV system was part of the larger Heritage Plaza Parking Lot Improvements Project and mounted on the two southern carport shade structures. The solar PV system will offset 99% of the approximately 115,000 kWh in electricity delivered annually by Southern California Edison (SCE) to the Tribal Education and Family Services offices at Heritage Plaza, reducing their annual energy costs from approximately $22,000 annually to approximately $200. The total cost of the proposed solar PV system is $240,000.

  20. Results of gas monitoring of double-shell flammable gas watch list tanks

    Wilkins, N.E.

    1995-01-01

    Tanks 103-SY; 101-AW; 103-, 104-, and 105-AN are on the Flammable Gas Watch List. Recently, standard hydrogen monitoring system (SHMS) cabinets have been installed in the vent header of each of these tanks. Grab samples have been taken once per week, and a gas chromatograph was installed on tank 104-AN as a field test. The data that have been collected since gas monitoring began on these tanks are summarized in this document