WorldWideScience

Sample records for garage radio beacon

  1. Recent progress in satellite radio beacon studies with particular emphasis on the ATS-6 radio beacon experiment

    International Nuclear Information System (INIS)

    Davies, K.

    1980-01-01

    In May 1974 a new era in satellite radio beacon studies of the ionosphere opened with the ATS-6 Radio Beacon Experiment. The history of radio beacon studies up to that time is reviewed briefly and the particular features of the ATS-6 beacon are discussed together with the basic theory required to interpret the measurements. The main emphasis is on the ATS-6 beacon experiment but other beacon data are discussed which provide the necessary background. The diurnal and seasonal variations of the total electron content and the plasmaspheric content are presented for the U.S.A. and Europe. In winter the plasmaspheric content over the Western Hemisphere maximizes at night while in Europe and the Pacific it appears to peak near noon. This is thought to be caused by flow of plasma from the local and conjugate ionospheres. Night maxima of total electron content are found showing that they do not arise from depletions of the plasmaspheric content. The plasmaspheric content is highly sensitive to solar-terrestrial disturbance, it reaches a minimum on the third day of a storm and may take between 10 and 20 days of partial filling and emptying to recover. Travelling disturbances in U.S.A., Europe, and India show similarities of speeds but not of direction. Beacon observations of micropulsations in total content, tropospheric fluctuations and Fresnel diffraction by intense ionospheric irregularities are discussed together with radio wave scintillations and some applications of beacon radio data to communications and navigation. (orig.)

  2. Some early results from the ATS-6 radio beacon experiment

    International Nuclear Information System (INIS)

    Davies, K.; Fritz, R.B.; Grubb, R.N.; Jones, J.E.

    1975-01-01

    The multifrequency satellite radio beacon enables the measurement of the columnar electron content of the ionosphere and plasmasphere along the ray path and its spatial and temporal structure. Measurements include modulation phase, Faraday rotation, and amplitude. The characteristics of the beacon transmitter and its design are presented together with the design of the Boulder receiver and antennas and the calibration procedures. A shape factor F is defined which depends on the electron density and geomagnetic field distributions. It is found that F varies by about 30 percent from day to night. It is shown that the ratio of the plasmaspheric content to total content varies from about 0.08 during the day to about 0.35 at night. Other examples which are presented to illustrate the uses of the radio beacon include sunrise effects, solar flare enhancements of total content, and the ionospheric storms of early July 1974

  3. Remote sensing of the ionosphere using satellite radio beacons

    International Nuclear Information System (INIS)

    Davies, Kenneth

    1991-01-01

    Since the launch of Sputnik I in 1957, satellite radio beacons have been used to measure the total electron content of the ionosphere. A review of the role of satellite beacons in studies of the vertical and spatial structure of the total electron content and on the occurrence of plasma irregularities, both of which affect transionospheric radio signals, is presented. Measurements of Faraday rotation and time of flight give information on the topside of the ionosphere and on the protonosphere. Morphological studies show that the slab thickness of the ionosphere depends on the solar index but is approximately independent of geographical location. Scintillation of amplitude, phase, polarization, and angle provide information on plasma irregularity occurrence in space and time. (author). 23 refs., 16 figs ., 4 tabs

  4. Radio beacon synchronization in coherent receivers for nanosatellite applications

    OpenAIRE

    Camps Llorente, Daniel; Piera González, Joan

    2017-01-01

    This document presents a study about the Radio beacon synchronization in coherent receivers for nanosatellite applications. First of all, it is studied the history of these nanosatellites and their actual role in the Aerospace industry, considering their low cost compared to bigger satellites and also because of their availability for all types of companies and people (as universities). These nanosatellites have a wide range of applications, and lots of them depend on the imagination of the u...

  5. 46 CFR 169.555 - Emergency position indicating radio beacon (EPIRB).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.555 Section 169.555 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... Emergency position indicating radio beacon (EPIRB). (a) Each vessel certificated for exposed waters must...

  6. 46 CFR 169.831 - Emergency position indicating radio beacon (EPIRB).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.831 Section 169.831 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... radio beacon (EPIRB). The master shall ensure that— (a) The EPIRB required in § 169.555 of this...

  7. 46 CFR 169.744 - Emergency position indicating radio beacon (EPIRB).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency position indicating radio beacon (EPIRB). 169.744 Section 169.744 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS... position indicating radio beacon (EPIRB). Each EPIRB must be marked with the vessel's name. ...

  8. Rayleigh beacon for measuring the surface profile of a radio telescope.

    Science.gov (United States)

    Padin, S

    2014-12-01

    Millimeter-wavelength Rayleigh scattering from water droplets in a cloud is proposed as a means of generating a bright beacon for measuring the surface profile of a radio telescope. A λ=3  mm transmitter, with an output power of a few watts, illuminating a stratiform cloud, can generate a beacon with the same flux as Mars in 10 GHz bandwidth, but the beacon has a narrow line width, so it is extremely bright. The key advantage of the beacon is that it can be used at any time, and positioned anywhere in the sky, as long as there are clouds.

  9. Some measurements of total electron content made with the ATS-6 radio beacon

    International Nuclear Information System (INIS)

    Davies, K.; Degenhardt, W.; Hartmann, G.K.

    1978-01-01

    The paper deals with some measurements made with the radio beacon on board the ATS-6 satellite in the American and European sectors. Measurements of the slant electron content, the Faraday content, and the plasmaspheric (or residual) content, made under different geographic and geomagnetic conditions, are discussed and compared

  10. ATS-6 radio beacon electron content measurements at Ootacamund, India, October 1975-July 1976

    International Nuclear Information System (INIS)

    Bouwer, S.D.; Davies, K.; Donnelly, R.F.; Grubb, R.N.; Jones, J.E.

    1980-03-01

    An atlas of total slant-path columnar electron content data measured between the ATS-6 satellite and Ootacamund, India, a site near the magnetic Equator is presented. Although these measurements were taken during a solar minimum, the general level of flare and geomagnetic activity that occurred during the observation period is summarized. These total content (N(T)) data were derived from the modulation phase (group delay) of a carrier signal transmitted from the geostationary satellite's Radio Beacon Experiment. This atlas contains two data sets: (1) N(T) as 2-min subsamples digitally recorded between 2 October 1975 and 28 January 1976 corrected for ATS-6 pitch maneuvers and (2) N(T) as 15-min subsamples chart recorded between 21 October 1975 and 22 July 1976 but uncorrected for changes in satellite orientation

  11. Observations of inner plasmasphere irregularities with a satellite-beacon radio-interferometer array

    International Nuclear Information System (INIS)

    Jacobson, A.R.; Hoogeveen, G.; Carlos, R.C.; Wu, G.; Fejer, B.G.; Kelley, M.C.

    1996-01-01

    A radio-interferometer array illuminated by 136-MHz beacons of several geosynchronous satellites has been used to study small (≥10 13 m -2 ) transient disturbances in the total electron content along the lines of sight to the satellites. High-frequency (f>3 mHz) electron content oscillations are persistently observed, particularly during night and particularly during geomagnetically disturbed periods. The oscillations move across the array plane at speeds in the range 200 endash 2000 m/s, with propagation azimuths that are strongly peaked in lobes toward the western half-plane. Detailed analysis of this azimuth behavior, involving comparison between observations on various satellite positions, indicates compellingly that the phase oscillations originate in radio refraction due to geomagnetically aligned plasma density perturbations in the inner plasmasphere. The motion of the phase perturbations across the array plane is caused by EXB drift of the plasma medium in which the irregularities are embedded. We review the statistics of 2.5 years of around-the-clock data on the local time, magnetic disturbance, seasonal, and line-of-sight variations of these observed irregularities. We compare the irregularities close-quote inferred electrodynamic drifts to what is known about midlatitude plasma drift from incoherent scatter. Finally, we show in detail how the observation of these irregularities provides a unique and complementary monitor of inner plasmasphere irregularity incidence and zonal drift.copyright 1996 American Geophysical Union

  12. Low and Mid-Latitude Ionospheric Irregularities Studies Using TEC and Radio Scintillation Data from the CITRIS Radio Beacon Receiver in Low-Earth-Orbit

    Science.gov (United States)

    Siefring, C. L.; Bernhardt, P. A.; Huba, J.; Krall, J.; Roddy, P. A.

    2009-12-01

    Unique data on ionospheric plasma irregularities from the Naval Research Laboratory (NRL) CITRIS (Scintillation and TEC Receiver in Space) instrument will be presented. CITRIS is a multi-band receiver that recorded TEC (Total Electron Content) and radio scintillations from Low-Earth Orbit (LEO) on STPSat1. The 555+/5 km altitude 35° inclination orbit covers low and mid-latitudes. The measurements require propagation from a transmitter to a receiver through the F-region plasma. CITRIS used both 1) satellite beacons in LEO, such as the NRL CERTO (Coherent Electromagnetic Radio TOmography) beacons and 2) the global network of ground-based DORIS (Doppler Orbitography and Radiopositioning Integrated by Satellite) beacons. The TEC measurements allow for tracking of ionospheric disturbances and irregularities while the measurements of scintillations can simultaneously characterize their effects. CITRIS was operated in a complementary fashion with the C/NOFS (Communication/Navigations Outages Forecasting System) satellite during most of its first year of operations. C/NOFS carries a three-frequency 150/400/1067 MHz CERTO beacon and is dedicated to the study of Spread-F. In the case of Spread-F, ionospheric irregularities start with large scale size density gradients (100s of km) and cascade through complex processes to short scale sizes (10s of meters). It is typically the 100m-1km scale features that harm communication and navigation systems through scintillations. A multi-sensor approach is needed to completely understand this complex system, such as, the combination of CITRIS remote radio sensing and C/NOFS in-situ data. Several types of irregularities have been studied including Spread-F and the newly discovered dawn-side depletions. Comparisons with the physics based SAMI3 model are being performed to help our understanding of the morphology of the irregularities.

  13. Results from the northern New Mexico satellite-beacon radio interferometer

    International Nuclear Information System (INIS)

    Carlos, R.; Jacobson, A.; Massey, R.; Wu, G.

    1994-01-01

    An interferometer described in the Boston, 1992, meeting of the Beacon Satellite Symposium has been in full operation for over a year now. It consists of four autonomous stations; three are in a triangle 70 km on a side and one is in the center. The stations receive the VHF beacons from two geosynchronous satellites, GOES-2 and ATS-3. The phases of the beacons are tracked at each station by referring them to an extremely stable rubidium oscillator. The studies of the two satellites are virtually separate experiments. The received phase of the beacon is retarded by the increased Total-Electron-Content of the dense regions of waves in the ionosphere. By comparing the phase history at four spatially separated stations, the authors can determine the two-dimensional propagation vector of the waves. This array is optimal for wavelengths of 70--300 km (periods of 300--3,000 seconds). Since the measurement is of the phase of the signal rather than the difference between the O-mode and X-mode phases, and since the beacons are in the VHF rather than in the L-band of GPS beacons, the array is very sensitive. It has a noise level of 10 13 electrons/m 2 , or 10 -4 of the normal daytime TEC. This has been verified by operating two stations in the same location, so that they saw the same ionosphere. The first interesting results from a year's study is that the authors do not see the same TID's when looking at the two satellites. One conclusion they draw is that they do not see evidence of ionospheric winds

  14. Beaconing Performance in IEEE 802.11p Vehicular Networks: the Effect of Radio Channel Congestion

    OpenAIRE

    Librino, Francesco; Renda, Maria Elena; Santi, Paolo

    2013-01-01

    In this paper, we study the performance of the beaconing mechanism underlying active safety vehicular applications in presence of different levels of channel congestion. The importance of this study lies in the fact that channel congestion is considered a major factor influencing communication performance in vehicular networks, and that ours is the first investigation of the effects of congestion based on extensive, real-world measurements. The results of our study reveal that congestion has ...

  15. 76 FR 17625 - Proposed Information Collection; Comment Request; Emergency Beacon Registrations

    Science.gov (United States)

    2011-03-30

    ... DEPARTMENT OF COMMERCE National Oceanic and Atmospheric Administration Proposed Information Collection; Comment Request; Emergency Beacon Registrations AGENCY: National Oceanic and Atmospheric... emergency radio beacon. Persons purchasing a digital distress beacon, operating in the frequency range of...

  16. Performance Evaluation of Relay Selection Schemes in Beacon-Assisted Dual-Hop Cognitive Radio Wireless Sensor Networks under Impact of Hardware Noises.

    Science.gov (United States)

    Hieu, Tran Dinh; Duy, Tran Trung; Dung, Le The; Choi, Seong Gon

    2018-06-05

    To solve the problem of energy constraints and spectrum scarcity for cognitive radio wireless sensor networks (CR-WSNs), an underlay decode-and-forward relaying scheme is considered, where the energy constrained secondary source and relay nodes are capable of harvesting energy from a multi-antenna power beacon (PB) and using that harvested energy to forward the source information to the destination. Based on the time switching receiver architecture, three relaying protocols, namely, hybrid partial relay selection (H-PRS), conventional opportunistic relay selection (C-ORS), and best opportunistic relay selection (B-ORS) protocols are considered to enhance the end-to-end performance under the joint impact of maximal interference constraint and transceiver hardware impairments. For performance evaluation and comparison, we derive the exact and asymptotic closed-form expressions of outage probability (OP) and throughput (TP) to provide significant insights into the impact of our proposed protocols on the system performance over Rayleigh fading channel. Finally, simulation results validate the theoretical results.

  17. Personal Beacon

    Science.gov (United States)

    2000-01-01

    The MicroPLB (personal locator beacon) is a search and rescue satellite-aided tracking (SARSAT) transmitter. When activated it emits a distress signal to a constellation of internationally operated satellites. The endangered person's identity and location anywhere on Earth is automatically forwarded to central monitoring stations around the world. It is accurate to within just a few meters. The user uses the device to download navigation data from a global positioning satellite receiver. After the download is complete, the MicroPLB functions as a self-locating beacon. Also, it is the only PLB to use a safe battery. In the past, other PLB devices have used batteries that have enough volatility to explode with extreme force. It was developed by Microwave Monolithic, Inc. through SBIR funding from Glenn Research Center and Goddard Space Flight Center.

  18. Nõukogude garaažikultuur. Soviet Garage Culture

    Directory of Open Access Journals (Sweden)

    Tauri Tuvikene

    2012-04-01

    draws on correspondents’ replies to the Estonian National Museum’s survey nr. 198 ’Bike. Car. Radio. Television’ (1997 regarding car usage in the Soviet era, as well as interviews and conversations with garage users over the course of five years. From these replies it became clear that the car did not only mean freedom of movement, which is what it is usually associated with, but it also became clear that the car required maintenance and effort, such as hands-on repair work at the garage. This gave rise to a place-centered kind of culture – a garage culture which was formed from neighbours socialising with one another, masculine car-centered activities, and transactions taking place outside of the official economic system.

  19. First observations of large-scale wave structure and equatorial spread F using CERTO radio beacon on the C/NOFS satellite

    Science.gov (United States)

    Thampi, S.; Yamamoto, M.; Tsunoda, R. T.; Otsuka, Y.; Tsugawa, T.; Uemoto, J.; Ishii, M.

    2009-12-01

    Equatorial spread F (ESF) is a generic name, which refers to the presence of a wide spectrum of field-aligned irregularities in the equatorial nighttime F-region that can extend over nearly seven orders of magnitude. Recently, a large-scale wave structure (LSWS) in the F-layer electron density is identified as a reliable precursor to ESF. The LSWS can be identified as a quasi-periodic modulation in the altitude of isoelectron density contours in the bottomside F-region, superimposed on a mean slope that increases in altitude from west to east. First observations of large-scale wave structure (LSWS) and the subsequent development of equatorial spread F (ESF), using total electron content (TEC) derived from the ground based reception of Coherent Electromagnetic Radio Tomography (CETRO) radio beacon signals on board the C/NOFS (Communications/Navigation Outage Forecasting System) satellite will be presented. For this study the TEC observations from Bac Lieu, Vietnam (9.2°N, 105.6°E geographic, 1.7°N magnetic dip latitude), Phukhet (7.8°N, 98.38°E, 0.4°S dip lat) and Kototabang, Indonesia (0.20°S, 100.32°E, 10.36°S dip lat) are analyzed along with ionosonde observations from Bac Lieu, Chumphon (10.7°N, 99.4°E, 3.3° dip lat) and 30.8 MHz VHF radar observations from Kototabang. It should also be mentioned here that LSWS is not easily detectable with overhead measurements using a sensor at a fixed location, at least not during its early growth phase, mainly because initially it grows in amplitude without significant zonal drift. The results indicate (1) LSWS appears to play a more important role in the development of ESF than the post-sunset rise (PSSR) of the F-layer, and (2) LSWS can appear well before E-region sunset. Other findings, that LSWS does not have significant zonal drift in the initial stages of growth, and can have zonal wavelengths of several hundred kilometers, corroborate earlier reports.

  20. A Route Guidance System for Car Finding in Indoor Parking Garages

    OpenAIRE

    Pei-Chun Lee; Sheng-Shih Wang

    2016-01-01

    This paper presents a route guidance system for car owners to find their cars in parking garages. The presents system comprises a positioning-assisting subsystem and a car-finding mobile app. The positioning-assisting subsystem mainly uses the iBeacon technology for indoor positioning. The car-finding mobile app guides car owners to their cars based on a non-map navigation strategy. This study also designs a virtual coordinate system to support identifying the locations of parking spaces and ...

  1. Good-bye Garage, Hello CCD

    Science.gov (United States)

    Augur, Eleanor

    1977-01-01

    The idea of having a religious education center in a four car garage may sound ridiculous to some but to the parishioners of Saint George's Church in Guilford, Connecticut, it was heaven-sent. (Author/RK)

  2. Molecular Beacons in Diagnostics

    OpenAIRE

    Tyagi, Sanjay; Kramer, Fred Russell

    2012-01-01

    Recent technical advances have begun to realize the potential of molecular beacons to test for diverse infections in clinical diagnostic laboratories. These include the ability to test for, and quantify, multiple pathogens in the same clinical sample, and to detect antibiotic resistant strains within hours. The design principles of molecular beacons have also spawned a variety of allied technologies.

  3. Auditory evacuation beacons

    NARCIS (Netherlands)

    Wijngaarden, S.J. van; Bronkhorst, A.W.; Boer, L.C.

    2005-01-01

    Auditory evacuation beacons can be used to guide people to safe exits, even when vision is totally obscured by smoke. Conventional beacons make use of modulated noise signals. Controlled evacuation experiments show that such signals require explicit instructions and are often misunderstood. A new

  4. Fire extinguishing system in large underground garages

    Directory of Open Access Journals (Sweden)

    Ivan Antonov

    2017-04-01

    Full Text Available In the work is considered an acceptable constructive scheme from a practical point of view at fire extinguishing in underground garages. The garage space is divided into quadrants which covering, for example, 2 cars. In case of ignition on one of them, a sprinkler nozzle system is triggered by the effect of the vertical convective jet. A protective curtain preventing the spread of fire to adjacent vehicles is realized. The solution is based on an integrated method which allows the calculation from hydrodynamic point of view on extinguishing time of the fire extinguishing system.

  5. A BLE-Based Pedestrian Navigation System for Car Searching in Indoor Parking Garages.

    Science.gov (United States)

    Wang, Sheng-Shih

    2018-05-05

    The continuous global increase in the number of cars has led to an increase in parking issues, particularly with respect to the search for available parking spaces and finding cars. In this paper, we propose a navigation system for car owners to find their cars in indoor parking garages. The proposed system comprises a car-searching mobile app and a positioning-assisting subsystem. The app guides car owners to their cars based on a “turn-by-turn” navigation strategy, and has the ability to correct the user’s heading orientation. The subsystem uses beacon technology for indoor positioning, supporting self-guidance of the car-searching mobile app. This study also designed a local coordinate system to support the identification of the locations of parking spaces and beacon devices. We used Android as the platform to implement the proposed car-searching mobile app, and used Bytereal HiBeacon devices to implement the proposed positioning-assisting subsystem. We also deployed the system in a parking lot in our campus for testing. The experimental results verified that the proposed system not only works well, but also provides the car owner with the correct route guidance information.

  6. Failure case of a garage door opener

    Directory of Open Access Journals (Sweden)

    Habib, K.

    2005-12-01

    Full Text Available A failure analysis of a garage door opener was conducted for determination of the cause of the failure. The analysis included visual inspections of broken parts as well as electron microscopy examinations of the fracture surface. The visual inspections showed that a bolt connected to the inner trolley of the garage opener assembly was initially fractured. Also, the results of electron microscopy examinations revealed that the broken bolt failed by fatigue damage phenomenon, due to alternating torsional stresses throughout 25 years of an operational life of the garage opener. In addition, a mathematical model corresponding to the failure mechanism was derived along the failure analysis. The model comprises of both design philosophy and fracture mechanics approaches.

    Se analizó el fallo del mecanismo de apertura de una puerta de garaje con el fin de determinar sus causas. El análisis incluyó una inspección visual de las piezas rotas así como un examen mediante microscopía de la superficie de fractura. La inspección visual reveló que primero se fracturó un perno conectado al carro interior del mecanismo de apertura. Los resultados del análisis por microscopía electrónica también mostraron que el perno roto falló debido a fenómenos de daño por fatiga, debido a los esfuerzos torsionales alternos a la largo de 25 años de vida en servicio del mecanismo de apertura. Por otra parte, se construyó un modelo matemático correspondiente al mecanismo de rotura durante el análisis del mismo. Este modelo comprende enfoques, tanto de la filosofía de diseño como de la mecánica de fractura.

  7. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Westford, MA (United States)

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  8. Air Leakage and Air Transfer Between Garage and Living Space

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  9. Salt attack in parking garage in block of flats

    Science.gov (United States)

    Beran, Pavel; Frankeová, Dita; Pavlík, Zbyšek

    2017-07-01

    In recent years many new block of flats with parking garages placed inside the buildings were constructed. This tendency brings beyond question benefits for residents and also for city planning, but it requires new design and structural approaches and advanced material and construction solutions. The analysis of plaster damage on partition wall in parking garage in one of these buildings is presented in the paper. The damage of studied plaster is caused by the salts which are transported together with snow on cars undercarriage into garage area during winter. The snow melts and water with dissolved salts is transported by the capillary suction from concrete floor into the rendered partition wall. Based on the interior temperature, adsorbed water with dissolved chlorides evaporates and from the over saturated pore solution are formed salt crystals that damages the surface plaster layers. This damage would not occur if the partition wall was correctly isolated from the floor finish layer in the parking garage.

  10. Environmental aspects of parking garages. Living in a compact city

    International Nuclear Information System (INIS)

    Koopmans, J.F.W.; Suverkoop, D.J.

    2005-01-01

    An overview is given of environmental aspects of parking garages in the Netherlands with respect to environmental legislation and regulations, focusing on noise pollution, lighting aspects (of cars and the parking buildings), air quality, and fire safety [nl

  11. COSPAS-SARSAT Beacon Certification Facility

    Data.gov (United States)

    Federal Laboratory Consortium — EPG's COSPAS-SARSAT Beacon Certification Facility is one of five certification facilities in the world. Formal certifications are available for all beacon types and...

  12. 47 CFR 97.203 - Beacon station.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Beacon station. 97.203 Section 97.203... SERVICE Special Operations § 97.203 Beacon station. (a) Any amateur station licensed to a holder of a Technician, Technician Plus, General, Advanced or Amateur Extra Class operator license may be a beacon. A...

  13. Identity verification using computer vision for automatic garage door opening

    NARCIS (Netherlands)

    Wijnhoven, R.G.J.; With, de P.H.N.

    2011-01-01

    We present a novel system for automatic identification of vehicles as part of an intelligent access control system for a garage entrance. Using a camera in the door, cars are detected and matched to the database of authenticated cars. Once a car is detected, License Plate Recognition (LPR) is

  14. Nanosecond-level time synchronization of AERA using a beacon reference transmitter and commercial airplanes

    Directory of Open Access Journals (Sweden)

    Huege Tim

    2017-01-01

    Full Text Available Radio detection of cosmic-ray air showers requires time synchronization of detectors on a nanosecond level, especially for advanced reconstruction algorithms based on the wavefront curvature and for interferometric analysis approaches. At the Auger Engineering Radio Array, the distributed, autonomous detector stations are time-synchronized via the Global Positioning System which, however, does not provide sufficient timing accuracy. We thus employ a dedicated beacon reference transmitter to correct for eventby-event clock drifts in our offline data analysis. In an independent cross-check of this “beacon correction” using radio pulses emitted by commercial airplanes, we have shown that the combined timing accuracy of the two methods is better than 2 nanoseconds.

  15. Nanosecond-level time synchronization of AERA using a beacon reference transmitter and commercial airplanes

    Science.gov (United States)

    Huege, Tim

    2017-03-01

    Radio detection of cosmic-ray air showers requires time synchronization of detectors on a nanosecond level, especially for advanced reconstruction algorithms based on the wavefront curvature and for interferometric analysis approaches. At the Auger Engineering Radio Array, the distributed, autonomous detector stations are time-synchronized via the Global Positioning System which, however, does not provide sufficient timing accuracy. We thus employ a dedicated beacon reference transmitter to correct for eventby-event clock drifts in our offline data analysis. In an independent cross-check of this "beacon correction" using radio pulses emitted by commercial airplanes, we have shown that the combined timing accuracy of the two methods is better than 2 nanoseconds.

  16. A simple statistical signal loss model for deep underground garage

    DEFF Research Database (Denmark)

    Nguyen, Huan Cong; Gimenez, Lucas Chavarria; Kovacs, Istvan

    2016-01-01

    In this paper we address the channel modeling aspects for a deep-indoor scenario with extreme coverage conditions in terms of signal losses, namely underground garage areas. We provide an in-depth analysis in terms of path loss (gain) and large scale signal shadowing, and a propose simple...... propagation model which can be used to predict cellular signal levels in similar deep-indoor scenarios. The proposed frequency-independent floor attenuation factor (FAF) is shown to be in range of 5.2 dB per meter deep....

  17. The ANTARES optical beacon system

    International Nuclear Information System (INIS)

    Ageron, M.; Aguilar, J.A.; Albert, A.

    2007-01-01

    ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented

  18. The ANTARES optical beacon system

    Energy Technology Data Exchange (ETDEWEB)

    Ageron, M. [CPPM - Centre de Physique des Particules de Marseille, CNRS/IN2P3 et Universite de la Mediterranee, 163 Avenue de Luminy, Case 902, 13288 Marseille Cedex 9 (France); Aguilar, J.A. [IFIC - Instituto de Fisica Corpuscular, Edificios de Investigacion de Paterna, CSIC - Universitat de Valencia, Apdo. de Correos 22085, 46071 Valencia (Spain)]. E-mail: J.A.Aguilar@ific.uv.es; Albert, A. [GRPHE - Groupe de Recherche en Physique des Hautes Energies, Universite de Haute Alsace, 61 Rue Albert Camus, 68093 Mulhouse Cedex (France)) (and others)

    2007-08-11

    ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented.

  19. The ANTARES optical beacon system

    Science.gov (United States)

    Ageron, M.; Aguilar, J. A.; Albert, A.; Ameli, F.; Anghinolfi, M.; Anton, G.; Anvar, S.; Ardellier-Desages, F.; Aslanides, E.; Aubert, J.-J.; Auer, R.; Barbarito, E.; Basa, S.; Battaglieri, M.; Becherini, Y.; Beltramelli, J.; Bertin, V.; Bigi, A.; Billault, M.; Blaes, R.; de Botton, N.; Bouwhuis, M. C.; Bradbury, S. M.; Bruijn, R.; Brunner, J.; Burgio, G. F.; Busto, J.; Cafagna, F.; Caillat, L.; Calzas, A.; Capone, A.; Caponetto, L.; Carmona, E.; Carr, J.; Cartwright, S. L.; Castel, D.; Castorina, E.; Cavasinni, V.; Cecchini, S.; Ceres, A.; Charvis, P.; Chauchot, P.; Chiarusi, T.; Circella, M.; Colnard, C.; Compère, C.; Coniglione, R.; Cottini, N.; Coyle, P.; Cuneo, S.; Cussatlegras, A.-S.; Damy, G.; van Dantzig, R.; de Bonis, G.; de Marzo, C.; de Vita, R.; Dekeyser, I.; Delagnes, E.; Denans, D.; Deschamps, A.; Destelle, J.-J.; Dinkespieler, B.; Distefano, C.; Donzaud, C.; Drogou, J.-F.; Druillole, F.; Durand, D.; Ernenwein, J.-P.; Escoffier, S.; Falchini, E.; Favard, S.; Fehr, F.; Feinstein, F.; Ferry, S.; Fiorello, C.; Flaminio, V.; Fratini, K.; Fuda, J.-L.; Galeotti, S.; Gallone, J.-M.; Giacomelli, G.; Girard, N.; Gojak, C.; Goret, Ph.; Graf, K.; Hallewell, G.; Harakeh, M. N.; Hartmann, B.; Heijboer, A.; Heine, E.; Hello, Y.; Hernández-Rey, J. J.; Hößl, J.; Hoffman, C.; Hogenbirk, J.; Hubbard, J. R.; Jaquet, M.; Jaspers, M.; de Jong, M.; Jouvenot, F.; Kalantar-Nayestanaki, N.; Kappes, A.; Karg, T.; Katz, U.; Keller, P.; Kok, E.; Kok, H.; Kooijman, P.; Kopper, C.; Korolkova, E. V.; Kouchner, A.; Kretschmer, W.; Kruijer, A.; Kuch, S.; Kudryavstev, V. A.; Lagier, P.; Lahmann, R.; Lamanna, G.; Lamare, P.; Lambard, G.; Languillat, J.-C.; Laschinsky, H.; Lavalle, J.; Le Guen, Y.; Le Provost, H.; Le van Suu, A.; Lefèvre, D.; Legou, T.; Lelaizant, G.; Lim, G.; Lo Presti, D.; Loehner, H.; Loucatos, S.; Louis, F.; Lucarelli, F.; Lyashuk, V.; Marcelin, M.; Margiotta, A.; Masullo, R.; Mazéas, F.; Mazure, A.; McMillan, J. E.; Megna, R.; Melissas, M.; Migneco, E.; Milovanovic, A.; Mongelli, M.; Montaruli, T.; Morganti, M.; Moscoso, L.; Musumeci, M.; Naumann-Godo, M.; Naumann, C.; Niess, V.; Noble, T.; Olivetto, C.; Ostasch, R.; Palanque-Delabrouille, N.; Payre, P.; Peek, H.; Perez, A.; Petta, C.; Piattelli, P.; Pillet, R.; Pineau, J.-P.; Poinsignon, J.; Popa, V.; Pradier, T.; Racca, C.; Randazzo, N.; van Randwijk, J.; Real, D.; van Rens, B.; Réthoré, F.; Rewiersma, P.; Riccobene, G.; Rigaud, V.; Ripani, M.; Roca, V.; Roda, C.; Rolin, J. F.; Rose, H. J.; Rostovtsev, A.; Roux, J.; Ruppi, M.; Russo, G. V.; Rusydi, G.; Salesa, F.; Salomon, K.; Sapienza, P.; Schmitt, F.; Schuller, J.-P.; Shanidze, R.; Sokalski, I.; Spona, T.; Spurio, M.; van der Steenhoven, G.; Stolarczyk, T.; Streeb, K.; Sulak, L.; Taiuti, M.; Tamburini, C.; Tao, C.; Terreni, G.; Thompson, L. F.; Urbano, F.; Valdy, P.; Valente, V.; Vallage, B.; Vaudaine, G.; Venekamp, G.; Verlaat, B.; Vernin, P.; de Vries-Uiterweerd, G.; van Wijk, R.; Wijnker, G.; de Witt Huberts, P.; Wobbe, G.; de Wolf, E.; Yao, A.-F.; Zaborov, D.; Zaccone, H.; Zornoza, J. D.; Zúñiga, J.

    2007-08-01

    ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three-dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular, when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented.

  20. On making radio contact with extraterrestrial civilizations

    International Nuclear Information System (INIS)

    Bates, D.R.

    1978-01-01

    The problem of attempting to make radio contact with other technological civilizations is examined. It is argued that there are few (perhaps indeed no) omnidirectional radio beacons in the Galaxy primarily because any such beacon, to be effective, would have to be designed for a call-response time of at least some 10 4 years, which is much too long to be likely to be acceptable to governments. A consequence is that any search program by us would have little chance of detecting incoming signals. (Auth.)

  1. Gold Nanoparticle-Based Sensors Activated by External Radio Frequency Fields

    DEFF Research Database (Denmark)

    Della Vedova, Paolo; Ilieva, Mirolyuba; Zhurbenko, Vitaliy

    2015-01-01

    A novel molecular beacon (a nanomachine) is constructed that can be actuated by a radio frequency (RF) field. The nanomachine consists of the following elements arranged in molecular beacon configuration: a gold nanoparticle that acts both as quencher for fluorescence and a localized heat source;...

  2. Multi-Band Multi-Tone Tunable Millimeter-Wave Frequency Synthesizer For Satellite Beacon Transmitter

    Science.gov (United States)

    Simons, Rainee N.; Wintucky, Edwin G.

    2016-01-01

    This paper presents the design and test results of a multi-band multi-tone tunable millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator. The intended application of the synthesizer is in a satellite beacon transmitter for radio wave propagation studies at K-band (18 to 26.5 GHz), Q-band (37 to 42 GHz), and E-band (71 to 76 GHz). In addition, the architecture for a compact beacon transmitter, which includes the multi-tone synthesizer, polarizer, horn antenna, and power/control electronics, has been investigated for a notional space-to-ground radio wave propagation experiment payload on a small satellite. The above studies would enable the design of robust high throughput multi-Gbps data rate future space-to-ground satellite communication links.

  3. Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-11-01

    In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  4. Searching for Cost-Optimized Interstellar Beacons

    Science.gov (United States)

    Benford, Gregory; Benford, James; Benford, Dominic

    2010-06-01

    What would SETI beacon transmitters be like if built by civilizations that had a variety of motives but cared about cost? In a companion paper, we presented how, for fixed power density in the far field, a cost-optimum interstellar beacon system could be built. Here, we consider how we should search for a beacon if it were produced by a civilization similar to ours. High-power transmitters could be built for a wide variety of motives other than the need for two-way communication; this would include beacons built to be seen over thousands of light-years. Extraterrestrial beacon builders would likely have to contend with economic pressures just as their terrestrial counterparts do. Cost, spectral lines near 1 GHz, and interstellar scintillation favor radiating frequencies substantially above the classic "water hole." Therefore, the transmission strategy for a distant, cost-conscious beacon would be a rapid scan of the galactic plane with the intent to cover the angular space. Such pulses would be infrequent events for the receiver. Such beacons built by distant, advanced, wealthy societies would have very different characteristics from what SETI researchers seek. Future searches should pay special attention to areas along the galactic disk where SETI searches have seen coherent signals that have not recurred on the limited listening time intervals we have used. We will need to wait for recurring events that may arriarrive in intermittent bursts. Several new SETI search strategies have emerged from these ideas. We propose a new test for beacons that is based on the Life Plane hypotheses.

  5. Occupational health risk of working in garages: comparative study on blood pressure and hematological parameters between garage workers and Haramaya University community, Harar, eastern Ethiopia.

    Science.gov (United States)

    Ataro, Zerihun; Geremew, Abraham; Urgessa, Fekadu

    2018-01-01

    Occupational exposure to chemicals in garages causes a wide range of biological effects, depending upon the level and duration of exposure. In Ethiopia, there have been few studies conducted to assess the exposure of garage workers to chemicals. Preceding studies have not explored the effect of working in garage on blood pressure and hematological parameters. Therefore, this study aimed to assess differences in blood pressure and hematological parameters among garage workers compared to the Haramaya University community, Harar, eastern Ethiopia. A comparative cross-sectional study was conducted in Harar town, eastern Ethiopia. Thirty garage workers were selected and compared with 30 age- and sex-matched controls comprising of teachers and students. Demographic and occupational data were collected by using a structured questionnaire by a trained data collector. Blood pressure was measured using sphygmomanometry. Hematological parameters were measured with an automated hematology analyzer. Data were analyzed using Stata version 13. The majority of the garage workers did not implement effective preventive or control measures for workplace chemical exposure. Statistically significant increases were found in systolic (128.67±18.14 vs 106.33 ±9.27 mmHg, P workers compared to the control group. On the other hand, statistically significant decreases were found in red blood cells (5.13±0.38 vs 5.46±0.36×10 12 cells/L, P =0.0006), hemoglobin (14.89±0.71 vs 15.45±0.87 g/dL, P =0.0062), hematocrit (43.98%±1.99% vs 46.4%3±2.32%, P workers compared to the control group. There were significant differences in blood pressure and hematological parameters between garage workers and the control group. Therefore, appropriate and effective safety measures need to be taken by the workers to prevent possible chemical exposure during routine tasks.

  6. Beach Advisory and Closing Online Notification (BEACON) system

    Data.gov (United States)

    U.S. Environmental Protection Agency — Beach Advisory and Closing Online Notification system (BEACON) is a colletion of state and local data reported to EPA about beach closings and advisories. BEACON is...

  7. Analysis and measure of novel stereo-garage driven by linear induction motor

    Directory of Open Access Journals (Sweden)

    Lu Qinfen

    2015-12-01

    Full Text Available The car access time is a key parameter, especially in a huge stereo-garage, where this one should be decreased as much as possible. This paper proposes a novel stereo-garage. Adopting the linear induction motors (LIMs, the system has a simple structure and rapid response capability. In the stereo-garage, several LIMs are installed below the crossbeam on a lifting platform, and several LIMs are fixed on the top of a moving frame. During the operation of LIMs, the moving frame moves forward and backward to reach the required parking place, whereas the crossbeam moves horizontally in order to take or store the vehicle rapidly. All these LIMs are the same and should be designed at a low frequency. The influences of key structure parameters and dynamic performances are investigated, based on FEM. The predicted results are validated by a prototype. Finally, the designed LIMs are successfully applied in two 8-layer stereo-garages.

  8. Pricing and availability intervention in vending machines at four bus garages.

    Science.gov (United States)

    French, Simone A; Hannan, Peter J; Harnack, Lisa J; Mitchell, Nathan R; Toomey, Traci L; Gerlach, Anne

    2010-01-01

    To evaluate the effects of lowering prices and increasing availability on sales of healthy foods and beverages from 33 vending machines in 4 bus garages as part of a multicomponent worksite obesity prevention intervention. Availability of healthy items was increased to 50% and prices were lowered at least 10% in the vending machines in two metropolitan bus garages for an 18-month period. Two control garages offered vending choices at usual availability and prices. Sales data were collected monthly from each of the vending machines at the four garages. Increases in availability to 50% and price reductions of an average of 31% resulted in 10% to 42% higher sales of the healthy items. Employees were mostly price responsive for snack purchases. Greater availability and lower prices on targeted food and beverage items from vending machines was associated with greater purchases of these items over an 18-month period. Efforts to promote healthful food purchases in worksite settings should incorporate these two strategies.

  9. BEACON: automated tool for Bacterial GEnome Annotation ComparisON

    KAUST Repository

    Kalkatawi, Manal M.; Alam, Intikhab; Bajic, Vladimir B.

    2015-01-01

    We developed BEACON, a fast tool for an automated and a systematic comparison of different annotations of single genomes. The extended annotation assigns putative functions to many genes with unknown functions. BEACON is available under GNU General Public License version 3.0 and is accessible at: http://www.cbrc.kaust.edu.sa/BEACON/

  10. 14 CFR 171.269 - Marker beacon performance requirements.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Marker beacon performance requirements. 171.269 Section 171.269 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Landing System (ISMLS) § 171.269 Marker beacon performance requirements. ISMLS marker beacon equipment...

  11. Doing Forensic on DTUsat-2 Using the Beacon Counter

    DEFF Research Database (Denmark)

    Fléron, René

    2016-01-01

    DTUsat-2 was launched into a Polar LEO on a Dnepr rocket out of Yasny on 19th June 2014. After the first few days of beacon recording and precise orbit determination it became apparent that all was not nominal. One notable thing was the relatively low beacon count number. The beacon count reflects...

  12. Influence of Parking Price on Parking Garage Users’ Behaviour

    Directory of Open Access Journals (Sweden)

    Jelena Simićević

    2012-09-01

    Full Text Available Parking charge is a powerful tool for solving parking and traffic congestion problems. In order to achieve the expected effects without any adverse impact it is necessary to understand well the users’ responses to this policy. This paper, based on a sample of interviewed parking garage users, has developed binary logit model for identification and quantification of characteristics of users and trips, on which the acceptance of parking price is dependent. In addition, multinomial logit model has been made in order to predict what the users will opt for when faced with an increase in parking price. For the first time the parameter “shorten duration” has been introduced which has shown to be the most significant in making behaviour-related decisions. The results show that the users with the purpose work are the most sensitive to an increase in parking charge, what can be deemed positive for policy makers. However, great sensitivity of the users with the purpose shopping should cause their concern. The results of the multinomial model show that they would not discontinue coming into the area after all.

  13. Solar powered aviation beacon/landing light

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The objective of the work was to design, develop and test Solar Powered Aviation Landing Lights/Obstruction Beacons. The entire lighting units were to be stand alone devices capable of producing their own individual power supply. The whole process was to be documented to provide insight into the processes and decisions involved. (author)

  14. An analytical model for beaconing in VANETs

    NARCIS (Netherlands)

    van Eenennaam, Martijn; Remke, Anne Katharina Ingrid; Heijenk, Geert

    2012-01-01

    IEEE 802.11 CSMA/CA is generally considered to be well-understood, and many detailed models are available. However, most models focus on Unicast in small-scale W-LAN scenarios. When modelling beaconing in VANETs, the Broadcast nature and the (potentially) large number of nodes cause phenomena

  15. Remote tracking of a magnetic receiver using low frequency beacons

    International Nuclear Information System (INIS)

    Sheinker, Arie; Ginzburg, Boris; Salomonski, Nizan; Frumkis, Lev; Kaplan, Ben-Zion

    2014-01-01

    Low frequency magnetic fields feature high penetration ability, which allows communication, localization, and tracking in environments where radio or acoustic waves are blocked or distorted by multipath interferences. In the present work, we propose a method for tracking a magnetic receiver using beacons of low frequency magnetic field, where the receiver includes a tri-axial search-coil magnetometer. Measuring the beacons’ magnetic fields and calculating the total-field signals enables localization without restrictions on magnetometer orientation, allowing on-the-move tracking. The total-field signals are used by a global search method, e.g., simulated annealing (SA) algorithm, to localize the receiver. The magnetic field produced by each beacon has a dipole structure and is governed by the beacon’s position and magnetic moment. We have investigated two different methods for estimating beacons’ magnetic moments prior to localization. The first method requires directional measurements, whereas for the second method the total-field signal is used. Effectiveness of these methods has been proved in numerous field tests. In the present work, we introduce a method for tracking a moving receiver by successive localizations. Using previous localization as a starting point of the search method for the next localization can reduce execution time and chances for divergence. The proposed method has been tested using numerous computer simulations. Successful system operation has been verified in field conditions. The good tracking capability together with simple implementation makes the proposed method attractive for real-time, low power field applications, such as mobile robots navigation. (paper)

  16. Respiratory symptoms and lung function in garage workers and taxi drivers.

    Science.gov (United States)

    Bener, A; Galadari, I; al-Mutawa, J K; al-Maskari, F; Das, M; Abuzeid, M S

    1998-12-01

    The aim of this study was to determine the prevalence of some respiratory symptoms and possible diseases among occupationally-exposed garage workers and taxi drivers. This study involved 158 garage workers and 165 taxi drivers, matched for age, sex, nationality and duration of employment. The mean age of 158 Indian subcontinent garage workers was 34.4 +/- 10.4 years; their mean height and weight were 167.7 +/- 6.6 cm and 72.0 +/- 12.3 kg respectively, and the mean duration of employment garage workers was 8.8 +/- 7.6 years. The mean age of 165 Indian subcontinent male taxi drivers was 34.5 +/- 7.7 years; their mean height and weight were 168.7 +/- 6.1 cm and 71.3 +/- 12.6 kg respectively; and the mean duration of employment was 7.5 +/- 5.4 years. The data on chronic respiratory symptoms showed that garage workers had higher prevalence of symptoms than taxi drivers being significantly greater for chronic phlegm, (p UAE), may be associated with the development of chronic respiratory symptoms and have effects on their daily life and health.

  17. Localization with a mobile beacon in underwater acoustic sensor networks.

    Science.gov (United States)

    Lee, Sangho; Kim, Kiseon

    2012-01-01

    Localization is one of the most important issues associated with underwater acoustic sensor networks, especially when sensor nodes are randomly deployed. Given that it is difficult to deploy beacon nodes at predetermined locations, localization schemes with a mobile beacon on the sea surface or along the planned path are inherently convenient, accurate, and energy-efficient. In this paper, we propose a new range-free Localization with a Mobile Beacon (LoMoB). The mobile beacon periodically broadcasts a beacon message containing its location. Sensor nodes are individually localized by passively receiving the beacon messages without inter-node communications. For location estimation, a set of potential locations are obtained as candidates for a node's location and then the node's location is determined through the weighted mean of all the potential locations with the weights computed based on residuals.

  18. Localization with a Mobile Beacon in Underwater Acoustic Sensor Networks

    Directory of Open Access Journals (Sweden)

    Sangho Lee

    2012-04-01

    Full Text Available Localization is one of the most important issues associated with underwater acoustic sensor networks, especially when sensor nodes are randomly deployed. Given that it is difficult to deploy beacon nodes at predetermined locations, localization schemes with a mobile beacon on the sea surface or along the planned path are inherently convenient, accurate, and energy-efficient. In this paper, we propose a new range-free Localization with a Mobile Beacon (LoMoB. The mobile beacon periodically broadcasts a beacon message containing its location. Sensor nodes are individually localized by passively receiving the beacon messages without inter-node communications. For location estimation, a set of potential locations are obtained as candidates for a node’s location and then the node’s location is determined through the weighted mean of all the potential locations with the weights computed based on residuals.

  19. High-visibility infrared beacons for IFF and combat ID

    Science.gov (United States)

    Pralle, Martin; Puscasu, Irina; Johnson, Edward; Loges, Peter; Melnyk, James

    2005-05-01

    A new kind of Identification Friend or Foe (IFF) infrared beacon has been demonstrated. The omni-directional beacon consists of a pyramidal array of 1W pulsIR thermal light sources. Operating at a total power of 84W, the beacon can be used to track and identify surface vehicles and personnel with a recognition range of up to 6 miles on the battlefield and in urban environments or the marine boundary layer. Advanced photonic technology enables the beacon to be seen only while using a 3-5 μm or 8-12 μm thermal imaging system. There is no visible or near-IR emission to betray the location of the beacon. The beacon is rugged and will operate from -40 to 50°C ambient temperature, 0-100% relative humidity, 0 - 10,000 ft altitude, and meets MIL-STD 810F and MIL-STD 461E.

  20. Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

    Energy Technology Data Exchange (ETDEWEB)

    2014-11-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  1. Aircraft Position Measurement Using Laser Beacon Optics.

    Science.gov (United States)

    1981-01-01

    8217Comparison of Solar Concentrators .’ Solar Energy, Vol. 10, p. 93, 1976. 7. Winston , R., ’Light Collection Within the Framework of Goemetrical Optics ...8217 J. Optical Society of Am., Vol. 60, p. 245, 1970. 8. Welford, W. T., tics of Nonimaging Concentrators . New York, Academic Press, T978. 9. Bracewell...helicopter pilot and the flight engineer on board the YO-3A. This thesis will concentrate on the development of the laser beacon, the detector optics

  2. Development of a universal RNA beacon for exogenous gene detection.

    Science.gov (United States)

    Guo, Yuanjian; Lu, Zhongju; Cohen, Ira Stephen; Scarlata, Suzanne

    2015-05-01

    Stem cell therapy requires a nontoxic and high-throughput method to achieve a pure cell population to prevent teratomas that can occur if even one cell in the implant has not been transformed. A promising method to detect and separate cells expressing a particular gene is RNA beacon technology. However, developing a successful, specific beacon to a particular transfected gene can take months to develop and in some cases is impossible. Here, we report on an off-the-shelf universal beacon that decreases the time and cost of applying beacon technology to select any living cell population transfected with an exogenous gene. ©AlphaMed Press.

  3. Radio tomographic imaging of sporadic-E layers during SEEK-2

    Directory of Open Access Journals (Sweden)

    P. A. Bernhardt

    2005-10-01

    Full Text Available During the SEEK-2 Rocket Campaign in August 2002, a Dual Band Beacon (DBB transmitting to Ground Receivers provided unique data on E-Region electron densities. Information from two rocket beacons and four ground receivers yielded multiple samples of E-region horizontal and vertical variations. The radio beacon measurements were made at four sites (Uchinoura, Tarumizu, Tanegashima, Takazaki in Japan for two rockets (S310-31 and S310-32 launched by the Institute of Space and Aeronautical Science (ISAS. Analysis was completed for four sets of beacon data to provide electron density images of sporadic-E layers. Signals from the two-frequency beacons on the SEEK-2 rockets were processed to yield total electron content (TEC data that was converted into electron density measurements. Wide variations in layer structures were detected. These included horizontal sporadic-E variations, vertical profiles of double, single, and weak layers. The radio beacon measurements were shown to be in agreement with the in-situ SEEK-2 sensors. The first tomographic image of a sporadic-E layer was produced from the data. The rocket beacon technique was shown to be an excellent tool to study sporadic-E layers because absolute TEC accuracy of 0.01 TEC Units can be easily obtained and, with proper receiver placement, electron density images can be produced using computerized ionospheric tomography with better than 1km horizontal and vertical resolution. Keywords. Ionospheric irregularities – Instruments and techniques – Mid-latitude ionosphere

  4. Pricing and Availability Intervention in Vending Machines at Four Bus Garages

    Science.gov (United States)

    Hannan, Peter J; Harnack, Lisa J; Mitchell, Nathan R; Toomey, Traci L; Gerlach, Anne

    2009-01-01

    Objective To evaluate the effects of lowering prices and increasing availability on sales of healthy foods and beverages from 33 vending machines in four bus garages as part of a multi-component worksite obesity prevention intervention. Methods Availability of healthy items was increased to 50% and prices were lowered at least 10% in the vending machines in two metropolitan bus garages for an 18-month period. Two control garages offered vending choices at usual availability and prices. Sales data were collected monthly from each of the vending machines at the four garages. Results Increases in availability to 50% and price reductions of an average of 31% resulted in 10-42% higher sales of the healthy items. Employees were most price-responsive for snack purchases. Conclusions Greater availability and lower prices on targeted food and beverage items from vending machines was associated with greater purchases of these items over an eighteen-month period. Efforts to promote healthful food purchases in worksite settings should incorporate these two strategies. PMID:20061884

  5. Constrained capacity management and cost minimisation of EV-charging in a parking garage

    NARCIS (Netherlands)

    Kamphuis, I.G.; Macdougall, P.; Veen, W. van der; Bakker, E.; Velde, J. van de

    2013-01-01

    Apart from the optimal real-time electricity price to buy the electricity, the optimal, time dependent, capacity contracted with the DSO is of crucial importance for concerted charging of electric vehicles in a parking garage. The battery management system, on its turn, imposes constraints on the

  6. The on-street parking premium and car drivers' choice between street and garage parking

    NARCIS (Netherlands)

    Kobus, M.B.W.; Gutierrez Puigarnau, E.; Rietveld, P.; van Ommeren, J.N.

    2013-01-01

    We introduce a methodology to estimate the effect of parking prices on car drivers' choice between street and garage parking. Our key identifying assumption is that the marginal benefit of parking duration does not depend on this choice. The endogeneity of parking duration is acknowledged in the

  7. Practical Fingerprinting Localization for Indoor Positioning System by Using Beacons

    Directory of Open Access Journals (Sweden)

    Santosh Subedi

    2017-01-01

    Full Text Available Recent developments in the fields of smartphones and wireless communication technologies such as beacons, Wi-Fi, and ultra-wideband have made it possible to realize indoor positioning system (IPS with a few meters of accuracy. In this paper, an improvement over traditional fingerprinting localization is proposed by combining it with weighted centroid localization (WCL. The proposed localization method reduces the total number of fingerprint reference points over the localization space, thus minimizing both the time required for reading radio frequency signals and the number of reference points needed during the fingerprinting learning process, which eventually makes the process less time-consuming. The proposed positioning has two major steps of operation. In the first step, we have realized fingerprinting that utilizes lightly populated reference points (RPs and WCL individually. Using the location estimated at the first step, WCL is run again for the final location estimation. The proposed localization technique reduces the number of required fingerprint RPs by more than 40% compared to normal fingerprinting localization method with a similar localization estimation error.

  8. Economic and environmental impacts of a PV powered workplace parking garage charging station

    International Nuclear Information System (INIS)

    Tulpule, Pinak J.; Marano, Vincenzo; Yurkovich, Stephen; Rizzoni, Giorgio

    2013-01-01

    Highlights: • Photovoltaic (PV) based, plug-in electric vehicle (PEV) charging station located in a workplace parking garage. • Emissions from the power grid. • Economic analysis. • Parametric analysis for parking rates, installed capacities to show benefits to vehicle and garage owner. - Abstract: Plug-in hybrid electric vehicles (PHEVs) and electric vehicles (EVs) have high potential for reducing fuel consumption and emissions, and for providing a way to utilize renewable energy sources for the transportation sector. On the other hand, charging millions of PEVs could overload the power grid, increase emissions and significantly alter economic characteristics. A day-time photovoltaic (PV) based, plug-in electric vehicle charging station located in a workplace parking garage is considered in this research. The results show the impact of PV based workplace charging on the economics and emissions from the power grid. An optimal charge scheduling strategy is compared with an uncontrolled charging case to perform the economics and emissions analysis. Two locations (Columbus, OH and Los Angeles, CA) are selected such that the analysis includes different scenarios of yearly variation of solar radiation and finance structure. A high fidelity hourly simulation model for energy economic analysis is developed considering different types of vehicles, statistical data for driving distances, parking time, installation cost, tax rebates and incentives. An incremental parking rate for accessing the charging facility is considered for economic analysis for the garage owner and the vehicle owner. The analysis is extended to consider the impact of carbon tax implementation on the driver economics and shows the feasibility of such PV based charging stations. Parametric analysis for different parking rates and installed capacities show (i) the feasibility of a PV based workplace charging facility, (ii) benefits to the vehicle owner and the garage owner, and (iii) the need for

  9. Beach Advisory and Closing Online Notification (BEACON) system

    Science.gov (United States)

    Beach Advisory and Closing Online Notification system (BEACON) is a colletion of state and local data reported to EPA about beach closings and advisories. BEACON is the public-facing query of the Program tracking, Beach Advisories, Water quality standards, and Nutrients database (PRAWN) which tracks beach closing and advisory information.

  10. 76 FR 65216 - Beacon Medical Services, LLC, Aurora, CO; Notice of Negative Determination Regarding Application...

    Science.gov (United States)

    2011-10-20

    ... DEPARTMENT OF LABOR Employment and Training Administration [TA-W-80,219] Beacon Medical Services... workers and former workers of Beacon Medical Services, LLC, Aurora, Colorado (Beacon Medical Services... published in the Federal Register on July 8, 2011 (76 FR 40401). The workers of Beacon Medical Services are...

  11. 78 FR 75392 - American Beacon Funds, et al.; Notice of Application

    Science.gov (United States)

    2013-12-11

    ... Asset Management LLC; (b) American Beacon Balanced Fund--the Manager, Barrow, Hanley, Mewhinney... Beacon Funds, et al.; Notice of Application December 5, 2013. AGENCY: Securities and Exchange Commission...) (order). Applicants: American Beacon Funds and American Beacon Select Funds (collectively, the ``Trusts...

  12. Occupational lead exposure among automotive garage workers – a case study for Jimma town, Ethiopia

    Directory of Open Access Journals (Sweden)

    Adela Yalemsew

    2012-07-01

    Full Text Available Abstract Background In Ethiopia, although there are numerous small-scale and medium industries which use lead-based raw materials that may pose health risks to workers, there are no workplace regulations for lead exposure. Moreover, there are no studies carried out on the blood lead levels (BLLs of workers or on the contribution of common workplace practices to lead poisoning. Method A cross-sectional study on the BLLs of 45 automotive garage workers and 40 non-garage workers was carried out in the town of Jimma, Ethiopia. In addition to BLL analysis, data on some risk factors such as smoking, and chewing ‘khat’ (the leaves of Catha adulis were gathered through structured questionnaires and interviews and data analysis was performed using SPSS (version 16. The t-test was used to compare mean BLLs of study groups. The analysis of variance (ANOVA, Kruskal-Wallis, Pearson chi-square and odds ratio tests were used to investigate the associations between specific job type, smoking and/or ‘khat’ chewing, service years and occurrence of non-specific symptoms with BLLs. Results The mean BLL of the automotive-garage workers was found to be significantly greater than that of the controls. The BLLs of all the lead-exposed individuals were found to be over 10 μg/dL, and 53% of them had BLLs ranging 12 – 20 μg/dL, with the remaining 47% having over 20 μg/dL. The BLL of the workers increased with the duration of working in an automotive garage. Individuals involved in manual car painting comprise a larger percentage (58% of those with the highest BLLs (≥ 20 μg/dL. Lead accumulation in individuals who chew ‘khat’ in the work place was found to be faster than in those who are not used to chewing ‘khat’. ‘Khat’ is an evergreen shrub native to tropical East Africa, with dark green opposite leaves which are chewed when fresh for their stimulating effects. Conclusion The findings of the study have clearly demonstrated that the

  13. Justification and choice of hardware for automatic control system by technical means at the garage consumer cooperative

    Directory of Open Access Journals (Sweden)

    Krasnykh V.Yu.

    2017-06-01

    Full Text Available the article describes the main system requirements of software of finished products for implementation of an automatic control system by technical means at the garage consumer cooperative.

  14. Diagnosis of Neisseria gonorrhoeae Using Molecular Beacon

    Science.gov (United States)

    Patel, Achchhe Lal; Sonkar, Subash Chandra; Kumari, Indu; Saluja, Daman

    2015-01-01

    Neisseria gonorrhoeae is an important sexually transmitted diseases (STD) causing pathogen worldwide. Due to absence of an affordable diagnostic assay, routine screening of gonococcal infection becomes impossible in developing countries where infection rates are maximum. Treatment is given on the basis of symptoms alone which leads to spread of infection. Thus, development of a rapid, sensitive, specific, and PCR based visual diagnostic assay suitable for developing countries, required for better disease management, is aimed at in present study. Endocervical swabs were collected from patients visiting gynecology department of various hospitals in Delhi. In-house PCR based assay was developed and modified to visual assay using molecular beacon for end-point detection. It was evaluated against Roche AMPLICOR NG kit and rmp gene. Specificity of beacon was confirmed by competition experiments. Diagnostic test was 98.21% specific and 99.59% sensitive whereas negative and positive predicted value were 99.40% and 98.78%, respectively. We also observed that twice the concentration (2X) of premix was stable at 4°C for 4 months and dry swab samples gave concordant results with that of wet swabs. These features make the test best suitable for routine diagnosis of genital infections in developing countries. PMID:25802857

  15. Molecular Beacon-Based MicroRNA Imaging During Neurogenesis.

    Science.gov (United States)

    Lee, Jonghwan; Kim, Soonhag

    2016-01-01

    The fluorescence monitoring system for examining endogenous microRNA (miRNA) activity in cellular level provides crucial information on not only understanding a critical role of miRNA involving a variety of biological processes, but also evaluating miRNA expression patterns in a noninvasive manner. In this protocol, we report the details of a new procedure for a molecular beacon-based miRNA monitoring system, which includes the illustration scheme for miRNA detection strategy, exogenous miRNA detection, and measurement of endogenous miRNA expression level during neurogenesis. The fluorescence signal of miR-124a beacon quenched by BHQ2 was gradually recovered as increasing concentration of the miR-124a in tube. The functional work of miR-124a beacon was examined in intracellular environment, allowing for the internalization of the miR-124a beacon by lipofectamine, which resulted in activated fluorescent signals of the miR-124a beacon in the HeLa cells after the addition of synthetic miR-124a. The endogenous miR-124a expression level was detected by miR-124a beacon system during neurogenesis, showing brighter fluorescence intensity in cytoplasmic area of P19 cells after induction of neuronal differentiation by retinoic acid. The molecular beacon based-miRNA detection technique could be applicable to the simultaneous visualization of a variety of miRNA expression patterns using different fluorescence dyes. For the study of examining endogenous miRNA expression level using miRNA-beacon system, if cellular differentiation step is already prepared, transfection step of miR-124a beacon into P19 cells, and acquisition of activated fluorescence signal measured by confocal microscope can be conducted approximately within 6 h.

  16. Do rufous hummingbirds (Selasphorus rufus) use visual beacons?

    Science.gov (United States)

    Hurly, T Andrew; Franz, Simone; Healy, Susan D

    2010-03-01

    Animals are often assumed to use highly conspicuous features of a goal to head directly to that goal ('beaconing'). In the field it is generally assumed that flowers serve as beacons to guide pollinators. Artificial hummingbird feeders are coloured red to serve a similar function. However, anecdotal reports suggest that hummingbirds return to feeder locations in the absence of the feeder (and thus the beacon). Here we test these reports for the first time in the field, using the natural territories of hummingbirds and manipulating flowers on a scale that is ecologically relevant to the birds. We compared the predictions from two distinct hypotheses as to how hummingbirds might use the visual features of rewards: the distant beacon hypothesis and the local cue hypothesis. In two field experiments, we found no evidence that rufous hummingbirds used a distant visual beacon to guide them to a rewarded location. In no case did birds abandon their approach to the goal location from a distance; rather they demonstrated remarkable accuracy of navigation by approaching to within about 70 cm of a rewarded flower's original location. Proximity varied depending on the size of the training flower: birds flew closer to a previously rewarded location if it had been previously signalled with a small beacon. Additionally, when provided with a beacon at a new location, birds did not fly directly to the new beacon. Taken together, we believe these data demonstrate that these hummingbirds depend little on visual characteristics to beacon to rewarded locations, but rather that they encode surrounding landmarks in order to reach the goal and then use the visual features of the goal as confirmation that they have arrived at the correct location.

  17. Low-Frequency Beacon Signal Strength Determination.

    Science.gov (United States)

    1980-01-01

    Radio Frequency List , RIS AF-6050-12 [141. Using this value and assum- ing performance for these facilities as indicatcd in FAA Handbook 6050.10, ERP...FAA Handbook 6050. 10 for facilities of appropriate transmitter power, determined from FAA Master Radio Frequency List 6050-12, April 1979...these facilities has not been directly measured and, therefore, values corresponding to transmitter powers given in FAA Master Radio Frequency List , RIS

  18. Snapshot analysis for rhodium fixed incore detector using BEACON methodology

    International Nuclear Information System (INIS)

    Cha, Kyoon Ho; Choi, Yu Sun; Lee, Eun Ki; Park, Moon Ghu; Morita, Toshio; Heibel, Michael D.

    2004-01-01

    The purpose of this report is to process the rhodium detector data of the Yonggwang nuclear unit 4 cycle 5 core for the measured power distribution by using the BEACON methodology. Rhodium snapshots of the YGN 4 cycle 5 have been analyzed by both BEACON/SPINOVA and CECOR to compare the results of both codes. By analyzing a large number of snapshots obtained during normal plant operation. Reviewing the results of this analysis, the BEACON/SPNOVA can be used for the snapshot analysis of Korean Standard Nuclear Power (KSNP) plants

  19. BEACON TSM application system to the operation of PWR reactors

    International Nuclear Information System (INIS)

    Lozano, J. A.; Mildrum, C.; Serrano, J. F.

    2012-01-01

    BEACON-TSM is an advanced core monitoring system for PWR reactor cores, and also offers the possibility to perform a wide range of predictive calculation in support of reactor operation. BEACON-TSM is presently installed and licensed in the 5 Spanish PWR reactors of standard Westinghouse design. the purpose of this paper is to describe the features of this software system and to show the advantages obtainable by a nuclear power plant from its use. To illustrate the capabilities and benefits of BEACON-TSM two real case reactor operating situations are presented. (Author)

  20. Garage carbon monoxide levels from sources commonly used in intentional poisoning.

    Science.gov (United States)

    Hampson, Neil B; Holm, James R; Courtney, Todd G

    2017-01-01

    The incidence of intentional carbon monoxide (CO) poisoning is believed to have declined due to strict federal CO emissions standards for motor vehicles and the uniform application of catalytic converters (CC). We sought to compare ambient CO levels produced by automobiles with and without catalytic converters in a residential garage, as well as from other CO sources commonly used for intentional poisoning. CO levels were measured inside a freestanding 73 m3 one-car garage. CO sources included a 1971 automobile without CC, 2003 automobile with CC, charcoal grill, electrical generator, lawn mower and leaf blower. After 20 minutes of operation, the CO level in the garage was 253 PPM for the car without a catalytic converter and 30 PPM for the car equipped withone. CO levels after operating or burning the other sources were: charcoal 200 PPM; generator >999 PPM; lawn mower 198 PPM; and leaf blower 580 PPM. While emissions controls on automobiles have reduced intentional CO poisonings, alternate sources may produce CO at levels of the same magnitude as vehicles manufactured prior to the use of catalytic converters. Those involved in the care of potentially suicidal individuals should be aware of this.

  1. Beacon-S TM: Non-uniform attenuation correction for SPECT imaging. The new medium-energy transmission device for AXIS and IRIX

    International Nuclear Information System (INIS)

    Daniel Gagnon, D.

    1999-01-01

    The paper presents new medium-energy transmission device for SPECT imaging. Beacon-S includes a 356-keV medium energy 133 Ba source with a 10.54-year half-life. Beacon-S provide high-resolution and high-contrast transmission scans. The higher energy of the gamma substantially improves the transmission contrast for larger patients by virtue of better penetration through the body

  2. Early Detection of Breast Cancer Using Molecular Beacons

    National Research Council Canada - National Science Library

    Yang, Lily

    2008-01-01

    .... We proposed to use molecular beacon technology to detect the level of expression of several biomarker genes that are highly expressed in breast cancer cells but not in normal breast epithelial cells...

  3. Evaluation of light-emitting diode beacon light fixtures.

    Science.gov (United States)

    2009-12-01

    Rotating beacons containing filament light sources have long been used on highway maintenance trucks : to indicate the presence of the truck to other drivers. Because of advances in light-emitting diode (LED) : technologies, flashing lights containin...

  4. Evaluation of BEACON-COLSS Core Monitoring System Benefits

    International Nuclear Information System (INIS)

    Kim, Joon Sung; Park, Young Ho; Morita, Toshio; Book, Michael A.

    2005-01-01

    In Korean Standard Nuclear Power Plant COLSS (Core Operating Limit Supervisory System) is used to monitor the DNBR Power Operating Limit (DNBRPOL) and Linear Heat Rate POL (KWPFPOL). Westinghouse and KNFC have developed an upgraded core monitoring system by combining the BEACON TM core monitoring system 1 (Best Estimate Analyzer for Core Operation . Nuclear) and COLSS into an integrated product that is called BEACON-COLSS. BEACON-COLSS generates the 3-D power distribution corrected by the in-core detectors measurements. The 3-D core power distribution methodology in BEACON-COLSS is significantly better than the synthesis methodology in COLSS. BEACONCOLSS uses the CETOP-D 2 thermal hydraulic code instead of CETOP-1. CETOP-D is a multi-channel thermal hydraulics code that will provide more accurate DNBR calculations than the DNBR calculators currently used in COLSS

  5. Pedestrian hybrid beacon guide : recommendations and case study.

    Science.gov (United States)

    2014-01-01

    A pedestrian hybrid beacon (PHB) is a traffic control : device similar to a European pedestrian signal : (PELICAN) that was imported to the US and adapted by : engineers in Arizona to increase motorists awareness of : pedestrian crossings at uncon...

  6. Radio astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Nagnibeda, V.G.

    1981-01-01

    The history of radio astronomical observations at the Astronomical Observatory of Leningrad State University is reviewed. Various facilities are described, and methods and instruments used are discussed. Some results are summarized for radio observations of the sun, including observations of local sources of solar radio emission, the absolute solar radio flux, and radio emission from filaments and prominences.

  7. A heuristic evaluation of the Facebook's advertising tool beacon

    OpenAIRE

    Jamal, A; Cole, M

    2009-01-01

    Interface usability is critical to the successful adoption of information systems. The aim of this study is to evaluate interface of Facebook's advertising tool Beacon by using privacy heuristics [4]. Beacon represents an interesting case study because of the negative media and user backlash it received. The findings of heuristic evaluation suggest violation of privacy heuristics [4]. Here, analysis identified concerns about user choice and consent, integrity and security of data, and awarene...

  8. Temporal change of EIA asymmetry revealed by a beacon receiver network in Southeast Asia

    Science.gov (United States)

    Watthanasangmechai, Kornyanat; Yamamoto, Mamoru; Saito, Akinori; Maruyama, Takashi; Yokoyama, Tatsuhiro; Nishioka, Michi; Ishii, Mamoru

    2015-05-01

    To reveal the temporal change of the equatorial ionization anomaly (EIA) asymmetry, a multipoint satellite-ground beacon experiment was conducted along the meridional plane of the Thailand-Indonesia sector. The observation includes one station near the magnetic equator and four stations at off-equator latitudes. This is the first EIA asymmetry study with high spatial resolution using GNU Radio Beacon Receiver (GRBR) observations in Southeast Asia. GRBR-total electron contents (TECs) from 97 polar-orbit satellite passes in March 2012 were analyzed in this study. Successive passes captured rapid evolution of EIA asymmetry, especially during geomagnetic disturbances. The penetrating electric fields that occur during geomagnetic disturbed days are not the cause of the asymmetry. Instead, high background TEC associated with an intense electric field empowers the neutral wind to produce severe asymmetry of the EIA. Such rapid evolution of EIA asymmetry was not seen during nighttime, when meridional wind mainly controlled the asymmetric structures. Additional data are necessary to identify the source of the variations, i.e., atmospheric waves. Precisely capturing the locations of the crests and the evolution of the asymmetry enhances understanding of the temporal change of EIA asymmetry at the local scale and leads to a future local modeling for TEC prediction in Southeast Asia.

  9. Beacon-Colss core monitoring system application and benefits

    International Nuclear Information System (INIS)

    Boyd, W.A.; Yoon, T.Y.

    2005-01-01

    Westinghouse and KNFC are creating an upgraded core monitoring system by merging the BEACON system (best estimate analyzer for core operation-nuclear) and COLSS (core operating limit supervisory system) into an integrated product. Although both BEACON and COLSS are core monitoring systems that have been in operation at many plants for a number of years, they each have some features and capabilities that are not in the other. Therefore it has been decided to incorporate portions of COLSS into the beacon system to create an optional level to support core monitoring applications on selected combustion engineering (C-E) designed plants. This optional level in the beacon system will be called BEACON-COLSS and will allow the beacon system to monitor the LCO's and Tech Spec limits at CE plants that currently use COLSS. This paper will present the structure of the new core monitoring system and the benefits it achieves for current COLSS plants, i.e., CE plants in the US and KSNP (Korean standard nuclear power plant). (authors)

  10. Computational study of smoke flow control in garage fires and optimization of the ventilation system

    Directory of Open Access Journals (Sweden)

    Banjac Miloš J.

    2009-01-01

    Full Text Available With the aim of evaluating capabilities of a ventilation system to control the spread of smoke in the emergency operating mode, thereby providing conditions for safe evacuation of people from a fire-struck area, computational fluid dynamics simulation of a fire in a semi-bedded garage was conducted. Using the experimental results of combustion dynamics of a passenger car on fire, optimal positions of ventilation openings were determined. According to recommendations by DIN EN 12101 standard, the operating modes of a ventilation system were verified and optimal start time of the smoke extraction system was defined.

  11. Research and Implementation of Automatic Fuzzy Garage Parking System Based on FPGA

    Directory of Open Access Journals (Sweden)

    Wang Kaiyu

    2016-01-01

    Full Text Available Because of many common scenes of reverse parking in real life, this paper presents a fuzzy controller which accommodates front and back adjustment of vehicle’s body attitude, and based on chaotic-genetic arithmetic to optimize the membership function of this controller, and get a vertical parking fuzzy controller whose simulation result is good .The paper makes the hardware-software embedded design for system based on Field-Programmable Gate Array (FPGA, and set up a 1:10 verification platform of smart car to verify the fuzzy garage parking system with real car. Verification results show that, the system can complete the parking task very well.

  12. Assessment of Material Solutions of Multi-level Garage Structure Within Integrated Life Cycle Design Process

    Science.gov (United States)

    Wałach, Daniel; Sagan, Joanna; Gicala, Magdalena

    2017-10-01

    The paper presents an environmental and economic analysis of the material solutions of multi-level garage. The construction project approach considered reinforced concrete structure under conditions of use of ordinary concrete and high-performance concrete (HPC). Using of HPC allowed to significant reduction of reinforcement steel, mainly in compression elements (columns) in the construction of the object. The analysis includes elements of the methodology of integrated lice cycle design (ILCD). By making multi-criteria analysis based on established weight of the economic and environmental parameters, three solutions have been evaluated and compared within phase of material production (information modules A1-A3).

  13. The use of BEACON monitoring in plant power uprates

    International Nuclear Information System (INIS)

    Miller, Wade

    2003-01-01

    BEACON is the core support software technology that provides Utilities with continuous 3-D core power distribution monitoring, operational analysis capability, and operations support capability. BEACON monitoring delivers quantifiable plant margins for both reload design and plant operations improvement. When linked to Plant Power Upratings, BEACON permits an improvement in fuel cycle economics through higher peaking factors, higher power levels and higher discharge burnups. Operational flexibility of Uprated Plants is enhanced through elimination of axial power shape and core power tilt specifications. Also, the number of flux maps for these plants is reduced and local power is monitored continuously, permitting faster power escalation. Integrated 3-D power distribution analysis capabilities provide core designers with historical margin data that permits a reduction in core follow requirements as well as reduced curve book data related scope. Examples of specific Uprated Plant applications will be discussed. In anticipation of future needs of Uprated Plants, plans to integrate the technology of BEACON with COLSS are being executed. Finally, the capability to monitor Crud Induced Power Shift (axial offset) is also planned for incorporation into BEACON in the near future and will be discussed

  14. 14 CFR 171.321 - DME and marker beacon performance requirements.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false DME and marker beacon performance... (MLS) § 171.321 DME and marker beacon performance requirements. (a) The DME equipment must meet the..._regulations/ibr_locations.html. (b) MLS marker beacon equipment must meet the performance requirements...

  15. 33 CFR 149.580 - What are the requirements for a radar beacon?

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false What are the requirements for a radar beacon? 149.580 Section 149.580 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF... Navigation Miscellaneous § 149.580 What are the requirements for a radar beacon? (a) A radar beacon (RACON...

  16. 77 FR 41271 - Safety Zone; Newburgh to Beacon Swim, Newburgh, Hudson River, NY

    Science.gov (United States)

    2012-07-13

    ... 1625-AA00 Safety Zone; Newburgh to Beacon Swim, Newburgh, Hudson River, NY AGENCY: Coast Guard, DHS... navigable waters of the Hudson River, NY in the vicinity of Newburgh, NY for the annual Newburgh Beacon Swim... Beacon Swim is an annual recurring event that has a permanent safety zone found at 33 CFR 165.160. The...

  17. Nucleic acid detection using BRET-beacons based on bioluminescent protein-DNA hybrids

    NARCIS (Netherlands)

    Engelen, W.; van de Wiel, K.M.; Meijer, L.H.H.; Saha, B.; Merkx, M.

    2017-01-01

    Bioluminescent molecular beacons have been developed using a modular design approach that relies on BRET between the bright luciferase NanoLuc and a Cy3 acceptor. While classical molecular beacons are hampered by background fluorescence and scattering, these BRET-beacons allow detection of low pM

  18. Information Dissemination in VANETS by Piggybacking on Beacons -- An Analysis of the Impact of Network Parameters

    NARCIS (Netherlands)

    Klein Wolterink, W.; Heijenk, Geert; Karagiannis, Georgios

    2011-01-01

    Piggybacking on beacons is a forwarding technique that is regularly used in vehicular ad-hoc network (VANET) research as a means to disseminate data. With this technique data is attached to and transmitted along with scheduled beacons, without changing the timing of the beacons. In this paper we

  19. Radio/FADS/IMU integrated navigation for Mars entry

    Science.gov (United States)

    Jiang, Xiuqiang; Li, Shuang; Huang, Xiangyu

    2018-03-01

    Supposing future orbiting and landing collaborative exploration mission as the potential project background, this paper addresses the issue of Mars entry integrated navigation using radio beacon, flush air data sensing system (FADS), and inertial measurement unit (IMU). The range and Doppler information sensed from an orbiting radio beacon, the dynamic pressure and heating data sensed from flush air data sensing system, and acceleration and attitude angular rate outputs from an inertial measurement unit are integrated in an unscented Kalman filter to perform state estimation and suppress the system and measurement noise. Computer simulations show that the proposed integrated navigation scheme can enhance the navigation accuracy, which enables precise entry guidance for the given Mars orbiting and landing collaborative exploration mission.

  20. Exploring the transformative potential of Bluetooth beacons in higher education

    Directory of Open Access Journals (Sweden)

    Kieran McDonald

    2016-11-01

    Full Text Available The growing ubiquity of smartphones and tablet devices integrated into personal, social and professional life, facilitated by expansive communication networks globally, has the potential to disrupt higher education. Academics and students are considering the future possibilities of exploiting these tools and utilising networks to consolidate and expand knowledge, enhancing learning gain. Bluetooth beacon technology has been developed by both Apple and Google as a way to situate digital information within physical spaces, and this paper reflects on a beacon intervention in a contemporary art school in higher education conducted by the authors intended to develop a situated community of practice in Art & Design. The paper describes the project, including relevant theoretical foundations and background to the beacon technology, with regards to the potential of using these devices to create a connected learning community by enhancing learning and facilitating knowledge creation in a borderless learning space.

  1. Detection of thermocouple malfunction in the Beacon system

    International Nuclear Information System (INIS)

    Morita, T.; Heibel, M.D.; Congedo, T.V.

    1992-01-01

    The BEACON system uses Core Exit Thermocouples (T/C) extensively for continuous radial power distribution monitoring. The T/C's are used to adjust the reference power distribution generated by the BEACON system to match the current radial power distribution. T/C reliability, repeatability, and relative accuracy have been very satisfactory. However, it is very important to detect any T/C malfunctions during operation, since a T/C signal change caused by an undetected malfunction can lead to serious errors in the radial power distribution developed by BEACON. A simple procedure has been developed which is capable of discriminating between changes in T/C signals caused by actual changes in reactor conditions and signal changes caused by T/C malfunctions

  2. Comparison of BEACON and COMPARE reactor cavity subcompartment analyses

    International Nuclear Information System (INIS)

    Burkett, M.W.; Idar, E.S.; Gido, R.G.; Lime, J.F.; Koestel, A.

    1984-04-01

    In this study, a more advanced best-estimate containment code, BEACON-MOD3A, was ued to calculate force and moment loads resulting from a high-energy blowdown for two reactor cavity geometries previously analyzed with the licensing computer code COMPARE-MOD1A. The BEACON force and moment loads were compared with the COMPARE results to determine the safety margins provided by the COMPARE code. The forces and moments calculated by the codes were found to be different, although not in any consistent manner, for the two reactor cavity geometries studied. Therefore, generic summary statements regarding margins cannot be made because of the effects of the detailed physical configuration. However, differences in the BEACON and COMPARE calculated forces and moments can be attributed to differences in the modeling assumptions used in the codes and the analyses

  3. Removal of oil and grease from automobile garage wastewater using electrocoagulation

    Science.gov (United States)

    Manilal, A. M.; Harinarayanan Nampoothiri, M. G.; Soloman, P. A.

    2017-06-01

    Wastewater from automobile garages and workshops is an important contributor to the water pollution. Oil and grease is one of the major content of wastewater from vehicle garages. Wastewater from a public transport depot at Thrissur district in Kerala, India was collected for the study. A batch reactor has been devised to assess the efficacy of electrocoagulation in removing oil and grease from the wastewater. Aluminium and iron were tested as the anode material with stainless steel as cathode. Experiments were conducted to investigate the effect of various operating parameters such as current density, pH, time and salt concentration on oil and grease removal. The results shown that aluminium is superior to iron in removing the oil and grease from the wastewater. The reactor with aluminium as anode was able to remove 90.8 % of the oil and grease at a current density of 0.6 A/dm2 in 15 minutes. The calculated specific energy consumption is also less for aluminium in comparison with iron.

  4. BEACON: automated tool for Bacterial GEnome Annotation ComparisON.

    Science.gov (United States)

    Kalkatawi, Manal; Alam, Intikhab; Bajic, Vladimir B

    2015-08-18

    Genome annotation is one way of summarizing the existing knowledge about genomic characteristics of an organism. There has been an increased interest during the last several decades in computer-based structural and functional genome annotation. Many methods for this purpose have been developed for eukaryotes and prokaryotes. Our study focuses on comparison of functional annotations of prokaryotic genomes. To the best of our knowledge there is no fully automated system for detailed comparison of functional genome annotations generated by different annotation methods (AMs). The presence of many AMs and development of new ones introduce needs to: a/ compare different annotations for a single genome, and b/ generate annotation by combining individual ones. To address these issues we developed an Automated Tool for Bacterial GEnome Annotation ComparisON (BEACON) that benefits both AM developers and annotation analysers. BEACON provides detailed comparison of gene function annotations of prokaryotic genomes obtained by different AMs and generates extended annotations through combination of individual ones. For the illustration of BEACON's utility, we provide a comparison analysis of multiple different annotations generated for four genomes and show on these examples that the extended annotation can increase the number of genes annotated by putative functions up to 27%, while the number of genes without any function assignment is reduced. We developed BEACON, a fast tool for an automated and a systematic comparison of different annotations of single genomes. The extended annotation assigns putative functions to many genes with unknown functions. BEACON is available under GNU General Public License version 3.0 and is accessible at: http://www.cbrc.kaust.edu.sa/BEACON/ .

  5. Beacon communities' public health initiatives: a case study analysis.

    Science.gov (United States)

    Massoudi, Barbara L; Marcial, Laura H; Haque, Saira; Bailey, Robert; Chester, Kelley; Cunningham, Shellery; Riley, Amanda; Soper, Paula

    2014-01-01

    The Beacon Communities for Public Health (BCPH) project was launched in 2011 to gain a better understanding of the range of activities currently being conducted in population- and public health by the Beacon Communities. The project highlighted the successes and challenges of these efforts with the aim of sharing this information broadly among the public health community. The Beacon Community Program, designed to showcase technology-enabled, community-based initiatives to improve outcomes, focused on: building and strengthening health information technology (IT) infrastructure and exchange capabilities; translating investments in health IT to measureable improvements in cost, quality, and population health; and, developing innovative approaches to performance measurement, technology, and care delivery. Four multimethod case studies were conducted based on a modified sociotechnical framework to learn more about public health initiative implementation and use in the Beacon Communities. Our methodological approach included using document review and semistructured key informant interviews. NACCHO Model Practice Program criteria were used to select the public health initiatives included in the case studies. Despite differences among the case studies, common barriers and facilitators were found to be present in all areas of the sociotechnical framework application including structure, people, technology, tasks, overarching considerations, and sustainability. Overall, there were many more facilitators (range = 7-14) present for each Beacon compared to barriers (range = 4-6). Four influential promising practices were identified through the work: forging strong and sustainable partnerships; ensuring a good task-technology fit and a flexible and iterative design; fostering technology acceptance; and, providing education and demonstrating value. A common weakness was the lack of a framework or model for the Beacon Communities evaluation work. Sharing a framework or approach

  6. Beacon Communities’ Public Health Initiatives: A Case Study Analysis

    Science.gov (United States)

    Massoudi, Barbara L.; Marcial, Laura H.; Haque, Saira; Bailey, Robert; Chester, Kelley; Cunningham, Shellery; Riley, Amanda; Soper, Paula

    2014-01-01

    Introduction: The Beacon Communities for Public Health (BCPH) project was launched in 2011 to gain a better understanding of the range of activities currently being conducted in population- and public health by the Beacon Communities. The project highlighted the successes and challenges of these efforts with the aim of sharing this information broadly among the public health community. Background: The Beacon Community Program, designed to showcase technology-enabled, community-based initiatives to improve outcomes, focused on: building and strengthening health information technology (IT) infrastructure and exchange capabilities; translating investments in health IT to measureable improvements in cost, quality, and population health; and, developing innovative approaches to performance measurement, technology, and care delivery. Methods: Four multimethod case studies were conducted based on a modified sociotechnical framework to learn more about public health initiative implementation and use in the Beacon Communities. Our methodological approach included using document review and semistructured key informant interviews. NACCHO Model Practice Program criteria were used to select the public health initiatives included in the case studies. Findings: Despite differences among the case studies, common barriers and facilitators were found to be present in all areas of the sociotechnical framework application including structure, people, technology, tasks, overarching considerations, and sustainability. Overall, there were many more facilitators (range = 7–14) present for each Beacon compared to barriers (range = 4–6). Discussion: Four influential promising practices were identified through the work: forging strong and sustainable partnerships; ensuring a good task-technology fit and a flexible and iterative design; fostering technology acceptance; and, providing education and demonstrating value. Conclusions: A common weakness was the lack of a framework or model for

  7. Development of a high-precision selenodetic coordinate system for the physical surface of the Moon based on LED beacons on its surface

    Science.gov (United States)

    Shirenin, A. M.; Mazurova, E. M.; Bagrov, A. V.

    2016-11-01

    The paper presents a mathematical algorithm for processing an array of angular measurements of light beacons on images of the lunar surface onboard a polar artificial lunar satellite (PALS) during the Luna-Glob mission and coordinate-time referencing of the PALS for the development of reference selenocentric coordinate systems. The algorithm makes it possible to obtain angular positions of point light beacons located on the surface of the Moon in selenocentric celestial coordinates. The operation of measurement systems that determine the position and orientation of the PALS during its active existence have been numerically simulated. Recommendations have been made for the optimal use of different types of measurements, including ground radio trajectory measurements, navigational star sensors based on the onboard star catalog, gyroscopic orientation systems, and space videos of the lunar surface.

  8. Frequency Estimator Performance for a Software-Based Beacon Receiver

    Science.gov (United States)

    Zemba, Michael J.; Morse, Jacquelynne Rose; Nessel, James A.; Miranda, Felix

    2014-01-01

    As propagation terminals have evolved, their design has trended more toward a software-based approach that facilitates convenient adjustment and customization of the receiver algorithms. One potential improvement is the implementation of a frequency estimation algorithm, through which the primary frequency component of the received signal can be estimated with a much greater resolution than with a simple peak search of the FFT spectrum. To select an estimator for usage in a QV-band beacon receiver, analysis of six frequency estimators was conducted to characterize their effectiveness as they relate to beacon receiver design.

  9. Optimalization of Beacon Selection for Localization in Wireless AD-HOC Networks

    Directory of Open Access Journals (Sweden)

    Martin Matula

    2008-01-01

    Full Text Available In this paper we engage in optimalization of convenient beacons for localization position of a node in the ad-hoc network. An algorithm designed by us localizes position of moving or static node by RSS (Received Signal Strength method and trilateration. At first, localization of unknown node runs by combination of all beacons. Than optimalizating algorithmreduces the number of beacons (and repeats localization, while only three left. Its reduction is based on highest levels of received signal strength. It is only when signals are from the nearest beacons. Position localizating exactness is statistically interpreted from all localization by beacons combination and its repeating.

  10. Radio stars

    International Nuclear Information System (INIS)

    Hjellming, R.M.

    1976-01-01

    Any discussion of the radio emission from stars should begin by emphasizing certain unique problems. First of all, one must clarify a semantic confusion introduced into radio astronomy in the late 1950's when most new radio sources were described as radio stars. All of these early 'radio stars' were eventually identified with other galactic and extra-galactic objects. The study of true radio stars, where the radio emission is produced in the atmosphere of a star, began only in the 1960's. Most of the work on the subject has, in fact, been carried out in only the last few years. Because the real information about radio stars is quite new, it is not surprising that major aspects of the subject are not at all understood. For this reason this paper is organized mainly around three questions: what is the available observational information; what physical processes seem to be involved; and what working hypotheses look potentially fruitful. (Auth.)

  11. Overshadowing of geometric cues by a beacon in a spatial navigation task.

    Science.gov (United States)

    Redhead, Edward S; Hamilton, Derek A; Parker, Matthew O; Chan, Wai; Allison, Craig

    2013-06-01

    In three experiments, we examined whether overshadowing of geometric cues by a discrete landmark (beacon) is due to the relative saliences of the cues. Using a virtual water maze task, human participants were required to locate a platform marked by a beacon in a distinctively shaped pool. In Experiment 1, the beacon overshadowed geometric cues in a trapezium, but not in an isosceles triangle. The longer escape latencies during acquisition in the trapezium control group with no beacon suggest that the geometric cues in the trapezium were less salient than those in the triangle. In Experiment 2, we evaluated whether generalization decrement, caused by the removal of the beacon at test, could account for overshadowing. An additional beacon was placed in an alternative corner. For the control groups, the beacons were identical; for the overshadow groups, they were visually unique. Overshadowing was again found in the trapezium. In Experiment 3, we tested whether the absence of overshadowing in the triangle was due to the geometric cues being more salient than the beacon. Following training, the beacon was relocated to a different corner. Participants approached the beacon rather than the trained platform corner, suggesting that the beacon was more salient. These results suggest that associative processes do not fully explain cue competition in the spatial domain.

  12. Robot-Beacon Distributed Range-Only SLAM for Resource-Constrained Operation.

    Science.gov (United States)

    Torres-González, Arturo; Martínez-de Dios, Jose Ramiro; Ollero, Anibal

    2017-04-20

    This work deals with robot-sensor network cooperation where sensor nodes (beacons) are used as landmarks for Range-Only (RO) Simultaneous Localization and Mapping (SLAM). Most existing RO-SLAM techniques consider beacons as passive devices disregarding the sensing, computational and communication capabilities with which they are actually endowed. SLAM is a resource-demanding task. Besides the technological constraints of the robot and beacons, many applications impose further resource consumption limitations. This paper presents a scalable distributed RO-SLAM scheme for resource-constrained operation. It is capable of exploiting robot-beacon cooperation in order to improve SLAM accuracy while meeting a given resource consumption bound expressed as the maximum number of measurements that are integrated in SLAM per iteration. The proposed scheme combines a Sparse Extended Information Filter (SEIF) SLAM method, in which each beacon gathers and integrates robot-beacon and inter-beacon measurements, and a distributed information-driven measurement allocation tool that dynamically selects the measurements that are integrated in SLAM, balancing uncertainty improvement and resource consumption. The scheme adopts a robot-beacon distributed approach in which each beacon participates in the selection, gathering and integration in SLAM of robot-beacon and inter-beacon measurements, resulting in significant estimation accuracies, resource-consumption efficiency and scalability. It has been integrated in an octorotor Unmanned Aerial System (UAS) and evaluated in 3D SLAM outdoor experiments. The experimental results obtained show its performance and robustness and evidence its advantages over existing methods.

  13. Can We Afford These Affordances? GarageBand and the Double-Edged Sword of the Digital Audio Workstation

    Science.gov (United States)

    Bell, Adam Patrick

    2015-01-01

    The proliferation of computers, tablets, and smartphones has resulted in digital audio workstations (DAWs) such as GarageBand in being some of the most widely distributed musical instruments. Positing that software designers are dictating the music education of DAW-dependent music-makers, I examine the fallacy that music-making applications such…

  14. A Case Study Exploring the Use of GarageBand[TM] and an Electronic Bulletin Board in Preservice Music Education

    Science.gov (United States)

    Vratulis, Vetta; Morton, Charlene

    2011-01-01

    This qualitative research study is an exploration of the merit and shortcomings of using a combination of the music software GarageBand[TM] and an electronic bulletin board to facilitate musical and peer learning in a 3-month elementary music methods curriculum and instruction course. A pedagogical objective of this assignment was to increase the…

  15. Faraday polarization fluctuations of satellite beacon signals

    Science.gov (United States)

    Lee, M. C.; Klobuchar, J. A.

    1988-01-01

    The anisotropic effects of random density irregularities in causing Faraday polarization fluctuations of VHF radio signals are examined, taking both rod-like and sheet-like irregularities into consideration. It is found that the variance of Faraday polarization fluctuations depends on the ratio of perpendicular to parallel correlation lengths. The anisotropic effect of rod-like ionospheric irregularities are shown to be most appreciable for longitudinal propagation. The anisotropic effect of sheet-like ionospheric irregularities, however, is not strongly dependent on the radio propagation angle. During transionospheric propagation at large angles with respect to the geomagnetic field, sheet-like irregularities may cause greater Faraday polarization fluctuations than rod-like irregularities.

  16. The BEACON on-line core monitoring system. Functional upgrades and applications

    International Nuclear Information System (INIS)

    Boyd, W.A.; Miller, R.W.

    1997-01-01

    The BEACON TM core monitor system has been in commercial operation since 1989 and was licensed by the USNRC for on-line core power distribution and thermal power limit monitoring in 1994. Since that time BEACON has been installed at 17 plants. Each of these customers has a different perspective on the use of data from BEACON and a different approach on the application of BEACON to support their plant operations. To support these varied needs and approaches the BEACON system has been divided into three operational levels to better match the system functions to the customer needs and approaches to system integration. Based on customer feedback, the BEACON system was upgraded in some areas and streamlined in other areas to better support the needs of each customer. The three operational levels of the BEACON system, the major product upgrades and system evolution that has taken place to support the needs and applications of our customers are discussed. (authors)

  17. A garage-building programme for the city of Vienna and resulting air quality. Related health aspects

    Energy Technology Data Exchange (ETDEWEB)

    Tvrdy, C; Walter, R [Inst. of Environmental Medicine of the City Council of Vienna (Austria)

    1996-12-31

    Urban traffic influences air quality in cities considerably. This is particularly true for the medieval parts of the big European cities, which have not been designed for today s heavy traffic. A problem closely associated with city traffic, is the lack of parking lots, particularly for residents. In Vienna, the parking problem is tackled by the building of underground car parks. In the next years more than 50 large garages (>100 sites) are being planned. The main goal is the clearing of the beautiful old places and streets of Vienna from the bulk of parking vehicles and supplying the citizens with parking spaces in the neighbourhood. According to a recent decision of the City Council of Vienna the construction of `large garages` (>100 parking spaces) requires an official approval by various local authorities. Among them are those responsible for town design and architecture, for fire precaution and fire fighting, for city traffic, for planning and building and for environmental health. In this context the Institute of Environmental Medicine of the City Council of Vienna faced the task of establishing criteria for a health risk assessment linked with `large garages`. Health-risks may be caused by air pollution and noise. This presentation deals with the air pollution problem. Air pollution problems may occur due to traffic in and out of the garage, by insufficient ventilation systems and by construction failures. In the garage programme the health officers have to bring evidence that residents of the houses with underground car parks and residents in the close neighbourhood are not exposed to any health risk due to air pollution

  18. A garage-building programme for the city of Vienna and resulting air quality. Related health aspects

    Energy Technology Data Exchange (ETDEWEB)

    Tvrdy, C.; Walter, R. [Inst. of Environmental Medicine of the City Council of Vienna (Austria)

    1995-12-31

    Urban traffic influences air quality in cities considerably. This is particularly true for the medieval parts of the big European cities, which have not been designed for today s heavy traffic. A problem closely associated with city traffic, is the lack of parking lots, particularly for residents. In Vienna, the parking problem is tackled by the building of underground car parks. In the next years more than 50 large garages (>100 sites) are being planned. The main goal is the clearing of the beautiful old places and streets of Vienna from the bulk of parking vehicles and supplying the citizens with parking spaces in the neighbourhood. According to a recent decision of the City Council of Vienna the construction of `large garages` (>100 parking spaces) requires an official approval by various local authorities. Among them are those responsible for town design and architecture, for fire precaution and fire fighting, for city traffic, for planning and building and for environmental health. In this context the Institute of Environmental Medicine of the City Council of Vienna faced the task of establishing criteria for a health risk assessment linked with `large garages`. Health-risks may be caused by air pollution and noise. This presentation deals with the air pollution problem. Air pollution problems may occur due to traffic in and out of the garage, by insufficient ventilation systems and by construction failures. In the garage programme the health officers have to bring evidence that residents of the houses with underground car parks and residents in the close neighbourhood are not exposed to any health risk due to air pollution

  19. Remarks on the observability of single beacon underwater navigation

    DEFF Research Database (Denmark)

    Jouffroy, Jerome; Ross, Andrew

    This paper contributes a simple and intuitive result in the analysis of underwater navigation using a single ranging beacon. This analysis should help with the design of small and lightweight underwater vehicles by reducing the amount of instrumentation required for accurate navigation. The concept...

  20. The Westinghouse BEACON on-line core monitoring system

    International Nuclear Information System (INIS)

    Buechel, Robert J.; Boyd, William A.; Casadei, Alberto L.

    1995-01-01

    BEACON (Best Estimate Analysis of Core Operations - Nuclear), a core monitoring and operational support package developed by Westinghouse, has been installed at many operating PWRs worldwide. The BEACON system is a real-time monitoring system which can be used in plants with both fixed and movable incore detector systems and utilizes an on-line nodal model combined with core instrumentation data to provide continuous core power distribution monitoring. In addition, accurate core-predictive capabilities utilizing a full core nodal model updated according to plant operating history can be made to provide operational support. Core history information is kept and displayed to help operators anticipate core behavior and take pro-active control actions. The BEACON system has been licensed by the U.S. Nuclear Regulatory Commission for direct, continuous monitoring of DNBR and peak linear heat rate. This allows BEACON to be integrated into the plant technical specifications to permit significant relaxation of operating limitations defined by conventional technical specifications. (author). 4 refs, 2 figs, 1 tab

  1. On the Efficiency of Secure Beaconing in VANETs

    NARCIS (Netherlands)

    Schoch, Elmar; Kargl, Frank

    Direct inter-vehicle communication enables numerous safety applications like intersection collision warning. Beacons - periodic one-hop link-layer broadcast messages containing, e.g., location, heading, and speed - are the basis for many such applications. For security, current work often requires

  2. Smartphone-Based Indoor Localization with Bluetooth Low Energy Beacons

    Directory of Open Access Journals (Sweden)

    Yuan Zhuang

    2016-04-01

    Full Text Available Indoor wireless localization using Bluetooth Low Energy (BLE beacons has attracted considerable attention after the release of the BLE protocol. In this paper, we propose an algorithm that uses the combination of channel-separate polynomial regression model (PRM, channel-separate fingerprinting (FP, outlier detection and extended Kalman filtering (EKF for smartphone-based indoor localization with BLE beacons. The proposed algorithm uses FP and PRM to estimate the target’s location and the distances between the target and BLE beacons respectively. We compare the performance of distance estimation that uses separate PRM for three advertisement channels (i.e., the separate strategy with that use an aggregate PRM generated through the combination of information from all channels (i.e., the aggregate strategy. The performance of FP-based location estimation results of the separate strategy and the aggregate strategy are also compared. It was found that the separate strategy can provide higher accuracy; thus, it is preferred to adopt PRM and FP for each BLE advertisement channel separately. Furthermore, to enhance the robustness of the algorithm, a two-level outlier detection mechanism is designed. Distance and location estimates obtained from PRM and FP are passed to the first outlier detection to generate improved distance estimates for the EKF. After the EKF process, the second outlier detection algorithm based on statistical testing is further performed to remove the outliers. The proposed algorithm was evaluated by various field experiments. Results show that the proposed algorithm achieved the accuracy of <2.56 m at 90% of the time with dense deployment of BLE beacons (1 beacon per 9 m, which performs 35.82% better than <3.99 m from the Propagation Model (PM + EKF algorithm and 15.77% more accurate than <3.04 m from the FP + EKF algorithm. With sparse deployment (1 beacon per 18 m, the proposed algorithm achieves the accuracies of <3.88 m at

  3. Wind energy. From the garage workshop to a global market. 25 years scientific accompaniment

    International Nuclear Information System (INIS)

    Hahn, Berthold; Stuebig, Cornelia; Ponick, Bernd; Keller, Sarina; Felder, Martin; Jachmann, Henning

    2015-01-01

    The plant technology for the use of wind energy on land is so sophisticated that the WEA can be operated as ''normal'' power plants to the grid. Of course, there are still potential for development, for example, in terms of improved reliability, or concerning the fledgling offshore use, always with an emphasis on the simultaneous reduction in costs. Although from the former garages workshops is little remaining, the production techniques are another major issue in terms of quality and costs. The cost of electricity from wind energy is taking account of external costs are already competitive with conventional power generation. To limit the costs of the energy transition one to expect from the wind energy as of the other technologies cost reduction. Various studies show that the wind energy supply in the balance is sufficient several times to provide the expected contribution to supply. [de

  4. Industrial scale garage-type dry fermentation of municipal solid waste to biogas.

    Science.gov (United States)

    Qian, M Y; Li, R H; Li, J; Wedwitschka, H; Nelles, M; Stinner, W; Zhou, H J

    2016-10-01

    The objectives of this study was to through monitoring the 1st industrial scale garage-type dry fermentation (GTDF) MSW biogas plant in Bin County, Harbin City, Heilongjiang Province, China, to investigate its anaerobic digestion (AD) performance and the stability of process. After a monitoring period of 180days, the results showed that the volumetric biogas production of the digesters and percolate tank was 0.72 and 2.22m(3) (m(3)d)(-1), respectively, and the specific biogas yield of the feedstock was about 270m(3)CH4tVS(-1), which indicated that the GTDF is appropriate for the Chinese MSW. This paper also raised some problems aimed at improving the process stability and AD efficiency. Copyright © 2016. Published by Elsevier Ltd.

  5. BEACON: automated tool for Bacterial GEnome Annotation ComparisON

    KAUST Repository

    Kalkatawi, Manal M.

    2015-08-18

    Background Genome annotation is one way of summarizing the existing knowledge about genomic characteristics of an organism. There has been an increased interest during the last several decades in computer-based structural and functional genome annotation. Many methods for this purpose have been developed for eukaryotes and prokaryotes. Our study focuses on comparison of functional annotations of prokaryotic genomes. To the best of our knowledge there is no fully automated system for detailed comparison of functional genome annotations generated by different annotation methods (AMs). Results The presence of many AMs and development of new ones introduce needs to: a/ compare different annotations for a single genome, and b/ generate annotation by combining individual ones. To address these issues we developed an Automated Tool for Bacterial GEnome Annotation ComparisON (BEACON) that benefits both AM developers and annotation analysers. BEACON provides detailed comparison of gene function annotations of prokaryotic genomes obtained by different AMs and generates extended annotations through combination of individual ones. For the illustration of BEACON’s utility, we provide a comparison analysis of multiple different annotations generated for four genomes and show on these examples that the extended annotation can increase the number of genes annotated by putative functions up to 27 %, while the number of genes without any function assignment is reduced. Conclusions We developed BEACON, a fast tool for an automated and a systematic comparison of different annotations of single genomes. The extended annotation assigns putative functions to many genes with unknown functions. BEACON is available under GNU General Public License version 3.0 and is accessible at: http://www.cbrc.kaust.edu.sa/BEACON/

  6. Smartphone-Based Indoor Localization with Bluetooth Low Energy Beacons.

    Science.gov (United States)

    Zhuang, Yuan; Yang, Jun; Li, You; Qi, Longning; El-Sheimy, Naser

    2016-04-26

    Indoor wireless localization using Bluetooth Low Energy (BLE) beacons has attracted considerable attention after the release of the BLE protocol. In this paper, we propose an algorithm that uses the combination of channel-separate polynomial regression model (PRM), channel-separate fingerprinting (FP), outlier detection and extended Kalman filtering (EKF) for smartphone-based indoor localization with BLE beacons. The proposed algorithm uses FP and PRM to estimate the target's location and the distances between the target and BLE beacons respectively. We compare the performance of distance estimation that uses separate PRM for three advertisement channels (i.e., the separate strategy) with that use an aggregate PRM generated through the combination of information from all channels (i.e., the aggregate strategy). The performance of FP-based location estimation results of the separate strategy and the aggregate strategy are also compared. It was found that the separate strategy can provide higher accuracy; thus, it is preferred to adopt PRM and FP for each BLE advertisement channel separately. Furthermore, to enhance the robustness of the algorithm, a two-level outlier detection mechanism is designed. Distance and location estimates obtained from PRM and FP are passed to the first outlier detection to generate improved distance estimates for the EKF. After the EKF process, the second outlier detection algorithm based on statistical testing is further performed to remove the outliers. The proposed algorithm was evaluated by various field experiments. Results show that the proposed algorithm achieved the accuracy of EKF algorithm and 15.77% more accurate than EKF algorithm. With sparse deployment (1 beacon per 18 m), the proposed algorithm achieves the accuracies of EKF algorithm and 21.41% better than EKF algorithm. Therefore, the proposed algorithm is especially useful to improve the localization accuracy in environments with sparse beacon deployment.

  7. Pulmonary function abnormalities associated with exposure to automobile exhaust in a diesel bus garage and roads.

    Science.gov (United States)

    Chattopadhyay, B P; Alam, J; Roychowdhury, A

    2003-01-01

    In Kolkata city the road transports are maintained by private and Government organization. A major work force belonged to the State Transport Corporation (KSTC), Government of West-Bengal. The pollution caused by these vehicles affects the workers health and caused different types of respiratory problems. This study was undertaken to assess the pulmonary function status of these workers. City KSTC garage workers were investigated and categorically divided into two group: garage mechanics and the (2) those transporting the passengers (drivers and conductors). Vital capacity (VC), forced vital capacity (FVC) and peak expiratory flow rate (PEFR) were recorded by Spirovit-SP-10 (Schiller Ltd, Switzerland) and Wright's Peak Flow Meter (UK) on 236 workers. The different flow volumes, FEV(1), FEV(1%), and flow rates, FEF(02-121), FEF(25-75%), etc. were calculated. The administrative people had higher PFT than the other categories. Drivers and conductors have almost equal mean PFT values but mechanical workers had slightly higher. PFT values according to different age ranges and duration of exposure showed gradual decrement as age and duration of exposure increased. Non-smokers had higher lung volumes compared to smokers and ex-smokers. Restrictive, obstructive and combined types of impairments were noticed in 28.4%, 1.7% and 2.9%, respectively, workers. The restrictive impairment was found to be 30.4% in conductors; 28.9% in drivers, 27.9% in mechanics and 21.7% in administration people. Obstructive type of impairment was found to be 2.9% in both drivers and conductors. The effect of pollution by dust and fumes may be responsible for these pulmonary function impairments, restrictive impairments being greater.

  8. The 1992 World Administrative Radio Conference: Technology and Policy Implications

    Science.gov (United States)

    1993-05-01

    As the 20th century draws to a close, new radio technologies and services are poised to change the ways we communicate. Radio waves already make possible a wide range of services considered commonplace--AM and FM radio broadcasting, television, cellular telephones, remote garage-door openers, and baby monitors. Advances in radio technology are giving birth to even more new products and services, including pocket-sized telephones that may allow people to make and receive calls anywhere in the world, high-definition televisions (HDTV) with superior quality pictures and sound, and static-free digital radios. The 1992 World Administrative Radio Conference (WARC-92) authorized frequencies for many of these new radio communication services, and granted additional frequencies for many existing services, including international broadcasting, satellite-based mobile communications, and communications in space. The effects of these changes will be felt well into the 21st century as countries around the world develop and deploy new communications systems to serve the needs of consumers, businesses, and governments. For the United States, the decisions made at the conference will critically affect how we develop new radio technologies and applications, how competitive this country will be in radio communications equipment and services, and how effectively the United States can exercise its role as a leader in world radio communication policymaking. This study of the outcomes and implications of WARC-92 was requested by the House Committee on Energy and Commerce and the Senate Committee on Commerce, Science, and Transportation. OTA was asked to evaluate the success of U.S. proposals at the conference, discuss the implications of the decisions made for U.S. technology and policy development, and identify options for improving U.S. participation in future world radio communication conferences.

  9. Radio stars

    International Nuclear Information System (INIS)

    Hjellming, R.M.; Gibson, D.M.

    1985-01-01

    Studies of stellar radio emission became an important field of research in the 1970's and have now expanded to become a major area of radio astronomy with the advent of new instruments such as the Very Large Array in New Mexico and transcontinental telescope arrays. This volume contains papers from the workshop on stellar continuum radio astronomy held in Boulder, Colorado, and is the first book on the rapidly expanding field of radio emission from stars and stellar systems. Subjects covered include the observational and theoretical aspects of stellar winds from both hot and cool stars, radio flares from active double star systems and red dwarf stars, bipolar flows from star-forming regions, and the radio emission from X-ray binaries. (orig.)

  10. Siim Nestor soovitab : Acid Mothers Temple. Dzhäss ja "tõsidus" NYYD Ensemble ilt. Garage, this is paradise. East-West / Siim Nestor

    Index Scriptorium Estoniae

    Nestor, Siim, 1974-

    2002-01-01

    Jaapani megaorkestri AMT esinemisest Linnakultuurifestivali üritusel "Operation B" Von Krahlis 8. nov. Estonia kontserdisaalis toimuvast ansambli NYYD kontserdist 11. nov. Klubis Wimbledon 8. nov. toimuvast peost "Garage, this is paradise". Saku Suurhallis toimuvast peost "East West"

  11. Beacon-based tourist information system to identify visiting trends of tourists

    Directory of Open Access Journals (Sweden)

    Akihiro Yamaguchi

    2017-11-01

    Full Text Available In this study, we propose a system that provides tourist information and obtains trends of visiting tourists using beacons and cloud service. As part of our research, we are working on the promotion of local area tourism in cooperation with a local community. A low energy Bluetooth device is used as a beacon to transmit a universally unique identifier. In addition, beacons are placed at sightseeing spots and tourist facilities. Our proposed system comprises two application programs; one is a client-side application program that provides area-specific tourist information corresponding to the detected beacon. The other is a server-side application to record time and location information of the detected beacons. In this paper, we describe the scheme of our system, and present the results of experiments conducted using the prototype system in the local tourist area. In addition, we discuss an open platform for information collection services using beacons.

  12. Worksite environment physical activity and healthy food choices: measurement of the worksite food and physical activity environment at four metropolitan bus garages

    Directory of Open Access Journals (Sweden)

    Gerlach Anne F

    2007-05-01

    Full Text Available Abstract Background The present research describes a measure of the worksite environment for food, physical activity and weight management. The worksite environment measure (WEM instrument was developed for the Route H Study, a worksite environmental intervention for weight gain prevention in four metro transit bus garages in Minneapolis-St. Paul. Methods Two trained raters visited each of the four bus garages and independently completed the WEM. Food, physical activity and weight management-related items were observed and recorded on a structured form. Inter-rater reliability was computed at the item level using a simple percentage agreement. Results The WEM showed high inter-rater reliability for the number and presence of food-related items. All garages had vending machines, microwaves and refrigerators. Assessment of the physical activity environment yielded similar reliability for the number and presence/absence of fitness items. Each garage had a fitness room (average of 4.3 items of fitness equipment. All garages had at least one stationary bike and treadmill. Three garages had at least one weighing scale available. There were no designated walking areas inside or outside. There were on average Conclusion The WEM is a reliable measure of the worksite nutrition, physical activity, and weight management environment that can be used to assess changes in the work environment.

  13. SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

    International Nuclear Information System (INIS)

    Amro, H; Chetty, I; Gordon, J; Wen, N

    2014-01-01

    Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in the phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation

  14. Q-Band (37-41 GHz) Satellite Beacon Architecture for RF Propagation Experiments

    Science.gov (United States)

    Simmons, Rainee N.; Wintucky, Edwin G.

    2012-01-01

    In this paper, the design of a beacon transmitter that will be flown as a hosted payload on a geostationary satellite to enable propagation experiments at Q-band (37-41 GHz) frequencies is presented. The beacon uses a phased locked loop stabilized dielectric resonator oscillator and a solid-state power amplifier to achieve the desired output power. The satellite beacon antenna is configured as an offset-fed cut-paraboloidal reflector.

  15. Q-Band (37 to 41 GHz) Satellite Beacon Architecture for RF Propagation Experiments

    Science.gov (United States)

    Simons, Rainee N.; Wintucky, Edwin G.

    2014-01-01

    In this paper, the design of a beacon transmitter that will be flown as a hosted payload on a geostationary satellite to enable propagation experiments at Q-band (37 to 41 GHz) frequencies is presented. The beacon uses a phased locked loop stabilized dielectric resonator oscillator and a solid-state power amplifier to achieve the desired output power. The satellite beacon antenna is configured as an offset-fed cutparaboloidal reflector.

  16. An Analysis of the Optimal Placement of Beacon in Bluetooth-INS Indoor Localization

    OpenAIRE

    Zhao, Xinyu; Ruan, Ling; Zhang, Ling; Long, Yi; Cheng, Fei

    2018-01-01

    The placement of Bluetooth beacon has immediate impact on the accuracy and stability of indoor positioning. Affected by the shelter of building and human, Bluetooth shows uncertain spatial transmission characteristics. Therefore, the scientific deployment of the beacon nodes is closely related to the indoor space environment. In the study of positioning technology using Bluetooth, some scholars have discussed the deployment of Bluetooth beacon in different scenarios. In the principle of avoid...

  17. SU-E-J-257: Image Artifacts Caused by Implanted Calypso Beacons in MRI Studies

    Energy Technology Data Exchange (ETDEWEB)

    Amro, H; Chetty, I; Gordon, J; Wen, N [Henry Ford Health System, Detroit, MI (United States)

    2014-06-01

    Purpose: The presence of Calypso Beacon-transponders in patients can cause artifacts during MRI imaging studies. This could be a problem for post-treatment follow up of cancer patients using MRI studies to evaluate metastasis and for functional imaging studies.This work assesses (1) the volume immediately surrounding the transponders that will not be visualized by the MRI due to the beacons, and (2) the dependence of the non-visualized volume on beacon orientation, and scanning techniques. Methods: Two phantoms were used in this study (1) water filled box, (2) and a 2300 cc block of pork meat. Calypso beacons were implanted in the phantoms both in parallel and perpendicular orientations with respect to the MR scanner magnetic field. MR image series of the phantom were obtained with on a 1.0T high field open MR-SIM with multiple pulse sequences, for example, T1-weighted fast field echo and T2-weighted turbo spin echo. Results: On average, a no-signal region with 2 cm radius and 3 cm length was measured. Image artifacts are more significant when beacons are placed parallel to scanner magnetic field; the no-signal area around the beacon was about 0.5 cm larger in orthogonal orientation. The no-signal region surrounding the beacons slightly varies in dimension for the different pulse sequences. Conclusion: The use of Calypso beacons can prohibit the use of MRI studies in post-treatment assessments, especially in the immediate region surrounding the implanted beacon. A characterization of the MR scanner by identifying the no-signal regions due to implanted beacons is essential. This may render the use of Calypso beacons useful for some cases and give the treating physician a chance to identify those patients prior to beacon implantation.

  18. Aftermath of bustamante attack on genomic beacon service.

    Science.gov (United States)

    Aziz, Md Momin Al; Ghasemi, Reza; Waliullah, Md; Mohammed, Noman

    2017-07-26

    With the enormous need for federated eco-system for holding global genomic and clinical data, Global Alliance for Genomic and Health (GA4GH) has created an international website called beacon service which allows a researcher to find out whether a specific dataset can be utilized to his or her research beforehand. This simple webservice is quite useful as it allows queries like whether a certain position of a target chromosome has a specific nucleotide. However, the increased integration of individuals genomic data into clinical practice and research raised serious privacy concern. Though the answer of such queries are yes or no in Bacon network, it results in serious privacy implication as demonstrated in a recent work from Shringarpure and Bustamante. In their attack model, the authors demonstrated that with a limited number of queries, presence of an individual in any dataset can be determined. We propose two lightweight algorithms (based on randomized response) which captures the efficacy while preserving the privacy of the participants in a genomic beacon service. We also elaborate the strength and weakness of the attack by explaining some of their statistical and mathematical models using real world genomic database. We extend their experimental simulations for different adversarial assumptions and parameters. We experimentally evaluated the solutions on the original attack model with different parameters for better understanding of the privacy and utility tradeoffs provided by these two methods. Also, the statistical analysis further elaborates the different aspects of the prior attack which leads to a better risk management for the participants in a beacon service. The differentially private and lightweight solutions discussed here will make the attack much difficult to succeed while maintaining the fundamental motivation of beacon database network.

  19. Caged molecular beacons: controlling nucleic acid hybridization with light.

    Science.gov (United States)

    Wang, Chunming; Zhu, Zhi; Song, Yanling; Lin, Hui; Yang, Chaoyong James; Tan, Weihong

    2011-05-28

    We have constructed a novel class of light-activatable caged molecular beacons (cMBs) that are caged by locking two stems with a photo-labile biomolecular interaction or covalent bond. With the cMBs, the nucleic acid hybridization process can be easily controlled with light, which offers the possibility for a high spatiotemporal resolution study of intracellular mRNAs. © The Royal Society of Chemistry 2011

  20. Beta aerosols beacon, a truly portable continuous air monitor

    International Nuclear Information System (INIS)

    Prince, R.P.; Garber, F.W.

    1987-01-01

    The Beta Aerosols Beacon (BAB) is a portable (57 lbs) continuous air monitor designed to detect airborne radiation. Utilizing solid state detectors has eliminated the use of lead shielding usually necessary for achieving accurate readings in high background areas, making the monitor lightweight as well as portable. The size of a small suitcase, it can be carried into confined work areas, eliminating the requirement for workers to wear respirators for many maintenance tasks. This paper describes the operation and applications of the BAB

  1. Performance of MAC protocols in beaconing Mobile Adhoc Multibroadcast Networks

    OpenAIRE

    Rico García, Cristina; Lehner, Andreas; Robertson, Patrick; Strang, Thomas

    2010-01-01

    The investigation of infrastructureless safety applications in dierent transportation systems is a hot research topic. The nodes in thevnetwork are designed to advertise to the rest of the nodes informationabout the current traffic situation by means of short beacon messages containing speed, direction, positions and other relevant safety information. The scheduling should be organized by the MAC layer so that the transmitted messages arrive successfully as soon as possible at the recei...

  2. Distributed Beacon Requirements for Branch Point Tolerant Laser Beam Compensation in Extended Atmospheric Turbulence

    National Research Council Canada - National Science Library

    Zetterlind, Virgil

    2002-01-01

    .... A least squares reconstructor is implemented for comparison. System performance is presented for various scenarios, including correction time-delays, wave-front sensor noise, and extended beacons...

  3. a Search for New Physics with the Beacon Mission

    Science.gov (United States)

    Turyshev, Slava G.; Shao, Michael; Girerd, André; Lane, Benjamin

    The primary objective of the Beyond Einstein Advanced Coherent Optical Network (BEACON) mission is a search for new physics beyond general relativity by measuring the curvature of relativistic space-time around the Earth. This curvature is characterized by the Eddington parameter γ — the most fundamental relativistic gravity parameter and a direct measure for the presence of new physical interactions. BEACON will achieve an accuracy of 1 × 10-9 in measuring the parameter γ, thereby going a factor of 30,000 beyond the present best result involving the Cassini spacecraft. Secondary mission objectives include: (i) a direct measurement of the "frame-dragging" and geodetic precessions in the Earth's rotational gravitomagnetic field, to 0.05% and 0.03% accuracy respectively, (ii) the first measurement of gravity's nonlinear effects on light and the corresponding second order spatial metric's effects to 0.01% accuracy. BEACON will lead to robust advances in tests of fundamental physics — this mission could discover a violation or extension of general relativity and/or reveal the presence of an additional long range interaction in physics. It will provide crucial information to separate modern scalar-tensor theories of gravity from general relativity, probe possible ways for gravity quantization, and test modern theories of cosmological evolution.

  4. Adapting Mobile Beacon-Assisted Localization in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Wei Dong

    2009-04-01

    Full Text Available The ability to automatically locate sensor nodes is essential in many Wireless Sensor Network (WSN applications. To reduce the number of beacons, many mobile-assisted approaches have been proposed. Current mobile-assisted approaches for localization require special hardware or belong to centralized localization algorithms involving some deterministic approaches due to the fact that they explicitly consider the impreciseness of location estimates. In this paper, we first propose a range-free, distributed and probabilistic Mobile Beacon-assisted Localization (MBL approach for static WSNs. Then, we propose another approach based on MBL, called Adapting MBL (A-MBL, to increase the efficiency and accuracy of MBL by adapting the size of sample sets and the parameter of the dynamic model during the estimation process. Evaluation results show that the accuracy of MBL and A-MBL outperform both Mobile and Static sensor network Localization (MSL and Arrival and Departure Overlap (ADO when both of them use only a single mobile beacon for localization in static WSNs.

  5. Adapting mobile beacon-assisted localization in wireless sensor networks.

    Science.gov (United States)

    Teng, Guodong; Zheng, Kougen; Dong, Wei

    2009-01-01

    The ability to automatically locate sensor nodes is essential in many Wireless Sensor Network (WSN) applications. To reduce the number of beacons, many mobile-assisted approaches have been proposed. Current mobile-assisted approaches for localization require special hardware or belong to centralized localization algorithms involving some deterministic approaches due to the fact that they explicitly consider the impreciseness of location estimates. In this paper, we first propose a range-free, distributed and probabilistic Mobile Beacon-assisted Localization (MBL) approach for static WSNs. Then, we propose another approach based on MBL, called Adapting MBL (A-MBL), to increase the efficiency and accuracy of MBL by adapting the size of sample sets and the parameter of the dynamic model during the estimation process. Evaluation results show that the accuracy of MBL and A-MBL outperform both Mobile and Static sensor network Localization (MSL) and Arrival and Departure Overlap (ADO) when both of them use only a single mobile beacon for localization in static WSNs.

  6. Impact of beacon wavelength on phase-compensation performance

    Science.gov (United States)

    Enterline, Allison A.; Spencer, Mark F.; Burrell, Derek J.; Brennan, Terry J.

    2017-09-01

    This study evaluates the effects of beacon-wavelength mismatch on phase-compensation performance. In general, beacon-wavelength mismatch occurs at the system level because the beacon-illuminator laser (BIL) and high-energy laser (HEL) are often at different wavelengths. Such is the case, for example, when using an aperture sharing element to isolate the beam-control sensor suite from the blinding nature of the HEL. With that said, this study uses the WavePlex Toolbox in MATLAB® to model ideal spherical wave propagation through various atmospheric-turbulence conditions. To quantify phase-compensation performance, we also model a nominal adaptive-optics (AO) system. We achieve correction from a Shack-Hartmann wavefront sensor and continuous-face-sheet deformable mirror using a least-squares phase reconstruction algorithm in the Fried geometry and a leaky integrator control law. To this end, we plot the power in the bucket metric as a function of BIL-HEL wavelength difference. Our initial results show that positive BIL-HEL wavelength differences achieve better phase compensation performance compared to negative BIL-HEL wavelength differences (i.e., red BILs outperform blue BILs). This outcome is consistent with past results.

  7. Solar Radio

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Scientists monitor the structure of the solar corona, the outer most regions of the Sun's atmosphere, using radio waves (100?s of MHz to 10?s of GHz). Variations in...

  8. Radio astronomy

    International Nuclear Information System (INIS)

    Parijskij, Y.N.; Gossachinskij, I.V.; Zuckerman, B.; Khersonsky, V.K.; Pustilnik, S.; Robinson, B.J.

    1976-01-01

    A critical review of major developments and discoveries in the field of radioastronomy during the period 1973-1975 is presented. The report is presented under the following headings:(1) Continuum radiation from the Galaxy; (2) Neutral hydrogen, 21 cm (galactic and extragalactic) and recombination lines; (3) Radioastronomy investigations of interstellar molecules; (4) Extragalactic radio astronomy and (6) Development in radio astronomy instruments. (B.R.H.)

  9. Mapping plasma structures in the high-latitude ionosphere using beacon satellite, incoherent scatter radar and ground-based magnetometer observations

    Directory of Open Access Journals (Sweden)

    T. Neubert

    2002-06-01

    Full Text Available In the autumn of the year 2000, four radio receivers capable of tracking various beacon satellites were set up along the southwestern coast of Greenland. They are used to reconstruct images of the ionospheric plasma density distribution via the tomographic method. In order to test and validate tomographic imaging under the highly variable conditions often prevailing in the high-latitude ionosphere, a time interval was selected when the Sondrestrom incoherent scatter radar conducted measurements of the ionospheric plasma density while the radio receivers tracked a number of beacon satellites. A comparison between two-dimensional images of the plasma density distribution obtained from the radar and the satellite receivers revealed generally good agreement between radar measurements and tomographic images. Observed discrepancies can be attributed to F region plasma patches moving through the field of view with a speed of several hundred meters per second, thereby smearing out the tomographic image. A notable mismatch occurred around local magnetic midnight when a magnetospheric substorm breakup occurred in the vicinity of southwest Greenland (identified from ground-based magnetometer observations. The breakup was associated with a sudden intensification of the westward auroral electrojet which was centered at about 69 and extended up to some 73 corrected geomagnetic latitude. Ground-based magnetometer data may thus have the potential of indicating when the tomographic method is at risk and may fail. We finally outline the application of tomographic imaging, when combined with magnetic field data, to estimate ionospheric Joule heating rates.

  10. Chimeric peptide beacons: a direct polypeptide analog of DNA molecular beacons†

    OpenAIRE

    Oh, Kenneth J.; Cash, Kevin J.; Lubin, Arica A.; Plaxco, Kevin W.

    2007-01-01

    We have developed a new biosensor architecture, which is comprised of a polypeptide–peptide nucleic acid tri-block copolymer and which we have termed chimeric peptide beacons (CPB), that generates an optical output via a mechanism analogous to that employed in DNA-based molecular beacons.

  11. Weak beacon detection for air-to-ground optical wireless link establishment.

    Science.gov (United States)

    Han, Yaoqiang; Dang, Anhong; Tang, Junxiong; Guo, Hong

    2010-02-01

    In an air-to-ground free-space optical communication system, strong background interference seriously affects the beacon detection, which makes it difficult to establish the optical link. In this paper, we propose a correlation beacon detection scheme under strong background interference conditions. As opposed to traditional beacon detection schemes, the beacon is modulated by an m-sequence at the transmitting terminal with a digital differential matched filter (DDMF) array introduced at the receiving end to detect the modulated beacon. This scheme is capable of suppressing both strong interference and noise by correlation reception of the received image sequence. In addition, the DDMF array enables each pixel of the image sensor to have its own DDMF of the same structure to process its received image sequence in parallel, thus it makes fast beacon detection possible. Theoretical analysis and an outdoor experiment have been demonstrated and show that the proposed scheme can realize fast and effective beacon detection under strong background interference conditions. Consequently, the required beacon transmission power can also be reduced dramatically.

  12. Synthesis and Characterization of a Magnetically Active 19F Molecular Beacon.

    Science.gov (United States)

    Dempsey, Megan E; Marble, Hetal D; Shen, Tun-Li; Fawzi, Nicolas L; Darling, Eric M

    2018-02-21

    Gene expression is used extensively to describe cellular characteristics and behaviors; however, most methods of assessing gene expression are unsuitable for living samples, requiring destructive processes such as fixation or lysis. Recently, molecular beacons have become a viable tool for live-cell imaging of mRNA molecules in situ. Historically, beacon-mediated imaging has been limited to fluorescence-based approaches. We propose the design and synthesis of a novel molecular beacon for magnetic resonance detection of any desired target nucleotide sequence. The biologically compatible synthesis incorporates commonly used bioconjugation reactions in aqueous conditions and is accessible for laboratories without extensive synthesis capabilities. The resulting beacon uses fluorine ( 19 F) as a reporter, which is broadened, or turned "off", via paramagnetic relaxation enhancement from a stabilized nitroxide radical spin label when the beacon is not bound to its nucleic acid target. Therefore, the 19 F NMR signal of the beacon is quenched in its hairpin conformation when the spin label and the 19 F substituent are held in proximity, but the signal is recovered upon beacon hybridization to its specific complementary nucleotide sequence by physical separation of the radical from the 19 F reporter. This study establishes a path for magnetic resonance-based assessment of specific mRNA expression, providing new possibilities for applying molecular beacon technology in living systems.

  13. Beacon Editor: Capturing Signal Transduction Pathways Using the Systems Biology Graphical Notation Activity Flow Language.

    Science.gov (United States)

    Elmarakeby, Haitham; Arefiyan, Mostafa; Myers, Elijah; Li, Song; Grene, Ruth; Heath, Lenwood S

    2017-12-01

    The Beacon Editor is a cross-platform desktop application for the creation and modification of signal transduction pathways using the Systems Biology Graphical Notation Activity Flow (SBGN-AF) language. Prompted by biologists' requests for enhancements, the Beacon Editor includes numerous powerful features for the benefit of creation and presentation.

  14. What Happened to the Beacon Schools? Policy Reform and Educational Equity

    Science.gov (United States)

    Smith, Emma

    2015-01-01

    This paper considers the impact of the Beacon schools initiative on the social and academic characteristics of secondary schools in England. The Beacon schools programme ran from 1998 to 2004 and epitomised the (then) Labour government's focus on school improvement through diversity, collaboration and partnership. This paper looks at variation in…

  15. Detecting and Preventing Beacon Replay Attacks in Receiver-Initiated MAC Protocols for Energy Efficient WSNs

    DEFF Research Database (Denmark)

    Di Mauro, Alessio; Fafoutis, Xenofon; Mödersheim, Sebastian Alexander

    2013-01-01

    In receiver-initiated MAC protocols for Wireless Sensor Networks (WSNs), communication is initiated by the receiver of the data through beacons containing the receiver's identity. In this paper, we consider the case of a network intruder that captures and replays such beacons towards legitimate...

  16. Beacon- and Schema-Based Method for Recognizing Algorithms from Students' Source Code

    Science.gov (United States)

    Taherkhani, Ahmad; Malmi, Lauri

    2013-01-01

    In this paper, we present a method for recognizing algorithms from students programming submissions coded in Java. The method is based on the concept of "programming schemas" and "beacons". Schemas are high-level programming knowledge with detailed knowledge abstracted out, and beacons are statements that imply specific…

  17. Crowdsourcing for Context: Regarding Privacy in Beacon Encounters via Contextual Integrity

    Directory of Open Access Journals (Sweden)

    Bello-Ogunu Emmanuel

    2016-07-01

    Full Text Available Research shows that context is important to the privacy perceptions associated with technology. With Bluetooth Low Energy beacons, one of the latest technologies for providing proximity and indoor tracking, the current identifiers that characterize a beacon are not sufficient for ordinary users to make informed privacy decisions about the location information that could be shared. One solution would be to have standardized category and privacy labels, produced by beacon providers or an independent third-party. An alternative solution is to find an approach driven by users, for users. In this paper, we propose a novel crowdsourcing based approach to introduce elements of context in beacon encounters.We demonstrate the effectiveness of this approach through a user study, where participants use a crowd-based mobile app designed to collect beacon category and privacy information as a scavenger hunt game. Results show that our approach was effective in helping users label beacons according to the specific context of a given beacon encounter, as well as the privacy perceptions associated with it. This labeling was done with an accuracy of 92%, and with an acceptance rate of 82% of all recommended crowd labels. Lastly, we conclusively show how crowdsourcing for context can be used towards a user-centric framework for privacy management during beacon encounters.

  18. Het effect van beacons in de ByAmfi Store gemeten, geanalyseerd en ontmaskerd

    NARCIS (Netherlands)

    Moes, Anne; van Vliet, Harry

    2015-01-01

    Volgens meerdere marketeers zijn beacons ‘the next big thing’; en grote retailers als de Bijenkorf zetten beacons al in. Klanten kopen namelijk steeds meer via internet, en winkels zoeken daarom naar manieren om een beleving te bieden, zodat klanten naar de winkel blijven komen.

  19. Uncertainty analysis for the BEACON-COLSS core monitoring system application

    International Nuclear Information System (INIS)

    Morita, T.; Boyd, W.A.; Seong, K.B.

    2005-01-01

    This paper will cover the measurement uncertainty analysis of BEACON-COLSS core monitoring system. The uncertainty evaluation is made by using a BEACON-COLSS simulation program. By simulating the BEACON on-line operation for analytically generated reactor conditions, accuracy of the 'Measured' results can be evaluated by comparing to analytically generated 'Truth'. The DNB power margin is evaluated based on the Combustion Engineering's Modified Statistical Combination of Uncertainties (MSCU) using the CETOPD code for the DNBR calculation. A BEACON-COLSS simulation program for the uncertainty evaluation function has been established for plant applications. Qualification work has been completed for two Combustion Engineering plants. Results of the BEACON-COLSS measured peaking factors and DNBR power margin are plant type dependent and are applicable to reload cores as long as the core geometry and detector layout are unchanged. (authors)

  20. Detection of DNA damage by using hairpin molecular beacon probes and graphene oxide.

    Science.gov (United States)

    Zhou, Jie; Lu, Qian; Tong, Ying; Wei, Wei; Liu, Songqin

    2012-09-15

    A hairpin molecular beacon tagged with carboxyfluorescein in combination with graphene oxide as a quencher reagent was used to detect the DNA damage by chemical reagents. The fluorescence of molecular beacon was quenched sharply by graphene oxide; while in the presence of its complementary DNA the quenching efficiency decreased because their hybridization prevented the strong adsorbability of molecular beacon on graphene oxide. If the complementary DNA was damaged by a chemical reagent and could not form intact duplex structure with molecular beacon, more molecular beacon would adsorb on graphene oxide increasing the quenching efficiency. Thus, damaged DNA could be detected based on different quenching efficiencies afforded by damaged and intact complementary DNA. The damage effects of chlorpyrifos-methyl and three metabolites of styrene such as mandelieaeids, phenylglyoxylieaeids and epoxystyrene on DNA were studied as models. The method for detection of DNA damage was reliable, rapid and simple compared to the biological methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Addressing Beacon re-identification attacks: quantification and mitigation of privacy risks.

    Science.gov (United States)

    Raisaro, Jean Louis; Tramèr, Florian; Ji, Zhanglong; Bu, Diyue; Zhao, Yongan; Carey, Knox; Lloyd, David; Sofia, Heidi; Baker, Dixie; Flicek, Paul; Shringarpure, Suyash; Bustamante, Carlos; Wang, Shuang; Jiang, Xiaoqian; Ohno-Machado, Lucila; Tang, Haixu; Wang, XiaoFeng; Hubaux, Jean-Pierre

    2017-07-01

    The Global Alliance for Genomics and Health (GA4GH) created the Beacon Project as a means of testing the willingness of data holders to share genetic data in the simplest technical context-a query for the presence of a specified nucleotide at a given position within a chromosome. Each participating site (or "beacon") is responsible for assuring that genomic data are exposed through the Beacon service only with the permission of the individual to whom the data pertains and in accordance with the GA4GH policy and standards.While recognizing the inference risks associated with large-scale data aggregation, and the fact that some beacons contain sensitive phenotypic associations that increase privacy risk, the GA4GH adjudged the risk of re-identification based on the binary yes/no allele-presence query responses as acceptable. However, recent work demonstrated that, given a beacon with specific characteristics (including relatively small sample size and an adversary who possesses an individual's whole genome sequence), the individual's membership in a beacon can be inferred through repeated queries for variants present in the individual's genome.In this paper, we propose three practical strategies for reducing re-identification risks in beacons. The first two strategies manipulate the beacon such that the presence of rare alleles is obscured; the third strategy budgets the number of accesses per user for each individual genome. Using a beacon containing data from the 1000 Genomes Project, we demonstrate that the proposed strategies can effectively reduce re-identification risk in beacon-like datasets. © The Author 2017. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  2. An Interactive Real-Time Locating System Based on Bluetooth Low-Energy Beacon Network †.

    Science.gov (United States)

    Lin, You-Wei; Lin, Chi-Yi

    2018-05-21

    The ubiquity of Bluetooth-enabled smartphones and peripherals has brought tremendous convenience to our daily life. In recent years, Bluetooth beacons have also been gaining popularity in implementing a variety of innovative location-based services such as self-guided systems in exhibition centers. However, the broadcast-based beacon technology can only provide unidirectional communication. In case smartphone users would like to respond to the beacon messages, they have to rely on their own mobile Internet connections to send the information back to the backend system. Nevertheless, mobile Internet services may not be always available or too costly. In this work, we develop a real-time locating system based only on the Bluetooth low energy (BLE) technology to support interactive communications by combining the broadcast and mesh topology options to extend the applicability of beacon solutions. Specifically, we turn the smartphone into a beacon device and augment the beacon devices with the capability of forming a mesh network. The implementation result shows that our beacon devices can detect the presence of specific users at specific locations, and then the presence state can be sent to the application server via the relay of beacon devices. Moreover, the application server can send personalized location-based messages to the users, again via the relay of beacon devices. With the capability of relaying messages between the beacon devices, it would be convenient for developers to implement a variety of interactive applications such as tracking VIP customers at the airport, or tracking an elder with Alzheimer’s disease in the neighborhood.

  3. An Interactive Real-Time Locating System Based on Bluetooth Low-Energy Beacon Network †

    Directory of Open Access Journals (Sweden)

    You-Wei Lin

    2018-05-01

    Full Text Available The ubiquity of Bluetooth-enabled smartphones and peripherals has brought tremendous convenience to our daily life. In recent years, Bluetooth beacons have also been gaining popularity in implementing a variety of innovative location-based services such as self-guided systems in exhibition centers. However, the broadcast-based beacon technology can only provide unidirectional communication. In case smartphone users would like to respond to the beacon messages, they have to rely on their own mobile Internet connections to send the information back to the backend system. Nevertheless, mobile Internet services may not be always available or too costly. In this work, we develop a real-time locating system based only on the Bluetooth low energy (BLE technology to support interactive communications by combining the broadcast and mesh topology options to extend the applicability of beacon solutions. Specifically, we turn the smartphone into a beacon device and augment the beacon devices with the capability of forming a mesh network. The implementation result shows that our beacon devices can detect the presence of specific users at specific locations, and then the presence state can be sent to the application server via the relay of beacon devices. Moreover, the application server can send personalized location-based messages to the users, again via the relay of beacon devices. With the capability of relaying messages between the beacon devices, it would be convenient for developers to implement a variety of interactive applications such as tracking VIP customers at the airport, or tracking an elder with Alzheimer’s disease in the neighborhood.

  4. Determination of BEACON Coupling Coefficients using data from Xenon transient

    International Nuclear Information System (INIS)

    Bozic, M.; Kurincic, B.

    2007-01-01

    NEK uses BEACO TM code (BEACO TM - Westinghouse Best Estimate Analyzer for Core Operating Nuclear) for core monitoring, analysis and core behaviour prediction. Coupling Coefficients determine relationship between core response and excore instrumentation. Measured power distribution using incore moveable detectors during Xenon transient with sufficient power axial offset change is the most important data for further analysis. Classic methodology and BEACO TM Conservative methodology using established Coupling Coefficients are compared on NPP Krsko case. BEACON TM Conservative methodology with predefined Coupling Coefficients is used as a surveillance tool for verification of relationship between core and excore instrumentation during power operation. (author)

  5. Beacon-teknologi - fremtidens kundebehandling eller en trussel for personvernet?

    OpenAIRE

    Jyrkinen, Anna; Kamås, Kamilla

    2016-01-01

    Smarttelefoner har blitt en naturlig del av våre liv. Alt man gjør på smarttelefonen, blir lagret som såkalte “big data”. Dette er verdifull informasjon for bedrifter, da de får mer detaljert bilde av hva forbrukere ser, eller holder på med i det virkelige liv. Det kan oppstå et dilemma ved hvor langt selskapene er villige til å strekke seg, for å samle inn informasjon om sine kunder. Beacons er en ny teknologiform og fungerer via små apparater som kommuniserer med kunder gjenn...

  6. Deep sea AUV navigation using multiple acoustic beacons

    Science.gov (United States)

    Ji, Da-xiong; Song, Wei; Zhao, Hong-yu; Liu, Jian

    2016-04-01

    Navigation is a critical requirement for the operation of Autonomous Underwater Vehicles (AUVs). To estimate the vehicle position, we present an algorithm using an extended Kalman filter (EKF) to integrate dead-reckoning position with acoustic ranges from multiple beacons pre-deployed in the operating environment. Owing to high latency, variable sound speed multipath transmissions and unreliability in acoustic measurements, outlier recognition techniques are proposed as well. The navigation algorithm has been tested by the recorded data of deep sea AUV during field operations in a variety of environments. Our results show the improved performance over prior techniques based on position computation.

  7. Radio astronomy

    CERN Document Server

    Alder, Berni

    1975-01-01

    Methods in Computational Physics, Volume 14: Radio Astronomy is devoted to the role of the digital computer both as a control device and as a calculator in addressing problems related to galactic radio noise. This volume contains four chapters and begins with a technical description of the hardware and the special data-handling problems of using radioheliography, with an emphasis on a selection of observational results obtained with the Culgoora radioheliograph and their significance to solar physics and to astrophysics in general. The subsequent chapter examines interstellar dispersion, i

  8. Overview of on-line core monitoring system BEACON

    International Nuclear Information System (INIS)

    Dai Qing; Chen Xiaosong

    2013-01-01

    After more than 20 years of development, key technologies embedded with such system have reached a certain degree of maturity among some foreign countries. However, domestically, there is no comparable system yet. Through in-depth research and analysis on the most widely used core monitoring system in the world, BEACON, it's hope that this will provide guidance on our independent development of the first core monitoring system in China. Excore detectors, core outlet thermocouples and incore movable detectors are used to provide measure data on the status of the core for BEACON. Under the assumption of nodal homogeneity, an effective fast group model is used to solve the diffusion equation, followed by core-wise interpolation by Green's function. Finally, reconstruction of a calculated core is fitted with measured data using the surface spline function. The most significant technological advances are core monitoring during unstable core conditions, the use of nodal expansion method to improve accuracy and the adoption of single point calibration to increase the period of recalibration for the whole core. (authors)

  9. Water absorption length measurement with the ANTARES optical beacon system

    International Nuclear Information System (INIS)

    Yepes-Ramirez, Harold

    2011-01-01

    ANTARES is a neutrino telescope located in the Mediterranean Sea with the aim of detecting high energy neutrinos of extra-terrestrial origin. It consists of a three dimensional array on 12 detection lines of photomultiplier tubes (PMTs) able to detect the Cherenkov light induced by muons produced in the interaction of neutrinos with the surrounding water and seabed. To reach the best angular resolution, good time and positioning calibrations are required. The propagation of Cherenkov photons strongly depends on the optical properties of the sea water, which has an impact on the reconstruction efficiency. The determination of the optical parameters, as the absorption and scattering lengths, is crucial to calculate properly the effective area and the angular resolution of the detector. The ANTARES optical beacon system consists of pulsed and fast, well controlled light sources distributed throughout the detector to carry out in situ the relative time calibration of the detector components. In this contribution we show some results on the sea water optical properties and their stability measured with the optical beacon system.

  10. Design and implementation of Bluetooth beacon in mobile payment system

    Science.gov (United States)

    Han, Tiantian; Ding, Lei

    2017-08-01

    The current line of payment means, mainly in the following ways, cash payment, credit card payment, WeChat Alipay sweep payment. There are many inconvenience in Cash payment, large amounts of cash inconvenience to carry, count the money to spend time and effort, true and false banknotes difficult to distinguish, ticket settlement easy to go wrong. Credit card payment is relatively time-consuming, and WeChat Alipay sweep payment need to sweep. Therefore, the design of a convenient, fast payment to meet the line to pay the demand is particularly important. Based on the characteristics of BLE Bluetooth wireless communication technology, this paper designs a kind of payment method based on Bluetooth beacon. Through the Bluetooth beacon broadcast consumption, consumers only need to open the relevant APP in the Android client, and you can get Bluetooth via mobile phone Bluetooth the amount of consumption of the standard broadcast, in accordance with the corresponding payment platform to complete the payment process, which pay less time to improve the efficiency of payment.

  11. Power-Efficient Beacon Recognition Method Based on Periodic Wake-Up for Industrial Wireless Devices.

    Science.gov (United States)

    Song, Soonyong; Lee, Donghun; Jang, Ingook; Choi, Jinchul; Son, Youngsung

    2018-04-17

    Energy harvester-integrated wireless devices are attractive for generating semi-permanent power from wasted energy in industrial environments. The energy-harvesting wireless devices may have difficulty in their communication with access points due to insufficient power supply for beacon recognition during network initialization. In this manuscript, we propose a novel method of beacon recognition based on wake-up control to reduce instantaneous power consumption in the initialization procedure. The proposed method applies a moving window for the periodic wake-up of the wireless devices. For unsynchronized wireless devices, beacons are always located in the same positions within each beacon interval even though the starting offsets are unknown. Using these characteristics, the moving window checks the existence of the beacon associated withspecified resources in a beacon interval, checks again for neighboring resources at the next beacon interval, and so on. This method can reduce instantaneous power and generates a surplus of charging time. Thus, the proposed method alleviates the problems of power insufficiency in the network initialization. The feasibility of the proposed method is evaluated using computer simulations of power shortage in various energy-harvesting conditions.

  12. DNA aptamer beacon assay for C-telopeptide and handheld fluorometer to monitor bone resorption.

    Science.gov (United States)

    Bruno, John Gordon; Carrillo, Maria P; Phillips, Taylor; Hanson, Douglas; Bohmann, Jonathan A

    2011-09-01

    A novel DNA aptamer beacon is described for quantification of a 26-amino acid C-telopeptide (CTx) of human type I bone collagen. One aptamer sequence and its reverse complement dominated the aptamer pool (31.6% of sequenced clones). Secondary structures of these aptamers were examined for potential binding pockets. Three-dimensional computer models which analyzed docking topologies and binding energies were in agreement with empirical fluorescence experiments used to select one candidate loop for beacon assay development. All loop structures from the aptamer finalists were end-labeled with TYE 665 and Iowa Black quencher for comparison of beacon fluorescence levels as a function of CTx concentration. The optimal beacon, designated CTx 2R-2h yielded a low ng/ml limit of detection using a commercially available handheld fluorometer. The CTx aptamer beacon bound full-length 26-amino acid CTx peptide, but not a shorter 8-amino acid segment of CTx peptide which is a common target for commercial CTx ELISA kits. The prototype assay was shown to detect CTx peptide from human urine after creatinine and urea were removed by size-exclusion chromatography to prevent nonspecific denaturing of the aptamer beacon. This work demonstrates the potential of aptamer beacons to be utilized for rapid and sensitive bone health monitoring in a handheld or point-of-care format.

  13. Pedestrian and motorists' actions at pedestrian hybrid beacon sites: findings from a pilot study.

    Science.gov (United States)

    Pulugurtha, Srinivas S; Self, Debbie R

    2015-01-01

    This paper focuses on an analysis of pedestrian and motorists' actions at sites with pedestrian hybrid beacons and assesses their effectiveness in improving the safety of pedestrians. Descriptive and statistical analyses (one-tail two-sample T-test and two-proportion Z-test) were conducted using field data collected during morning and evening peak hours at three study sites in the city of Charlotte, NC, before and after the installation of pedestrian hybrid beacons. Further, an analysis was conducted to assess the change in pedestrian and motorists' actions over time (before the installation; 1 month, 3 months, 6 months, and 12 months after the installation). Results showed an increase in average traffic speed at one of the pedestrian hybrid beacon sites while no specific trends were observed at the other two pedestrian hybrid beacon sites. A decrease in the number of motorists not yielding to pedestrians, pedestrians trapped in the middle of the street, and pedestrian-vehicle conflicts were observed at all the three pedestrian hybrid beacon sites. The installation of pedestrian hybrid beacons did not have a negative effect on pedestrian actions at two out of the three sites. Improvements seem to be relatively more consistent 3 months after the installation of the pedestrian hybrid beacon.

  14. Easy-to-Build Satellite Beacon Receiver for Propagation Experimentation at Millimeter Bands

    Directory of Open Access Journals (Sweden)

    F. Machado

    2014-04-01

    Full Text Available This paper describes the design and development of a digital satellite beacon receiver for propagation experimentation. Satellite beacons are frequently available for pointing large antennas, but such signals can be used for measuring rain attenuation and other phenomena as, for example, tropospheric scintillation. A fairly inexpensive beacon receiver has been built using off-the-shelf parts. This instrument is not at all bulky making it suitable for easy transportation. This article analyzes the receiver specifications, describes in detail its structure and presents some operational test results.

  15. Tight Bounds for Beacon-Based Coverage in Simple Rectilinear Polygons

    KAUST Repository

    Bae, Sang Won; Shin, Chan-Su; Vigneron, Antoine E.

    2016-01-01

    We establish tight bounds for beacon-based coverage problems. In particular, we show that $$\\lfloor \\frac{n}{6} \\rfloor $$⌊n6⌋ beacons are always sufficient and sometimes necessary to cover a simple rectilinear polygon P with n vertices. When P is monotone and rectilinear, we prove that this bound becomes $$\\lfloor \\frac{n+4}{8} \\rfloor $$⌊n+48⌋. We also present an optimal linear-time algorithm for computing the beacon kernel of P.

  16. Tight Bounds for Beacon-Based Coverage in Simple Rectilinear Polygons

    KAUST Repository

    Bae, Sang Won

    2016-03-21

    We establish tight bounds for beacon-based coverage problems. In particular, we show that $$\\\\lfloor \\\\frac{n}{6} \\ floor $$⌊n6⌋ beacons are always sufficient and sometimes necessary to cover a simple rectilinear polygon P with n vertices. When P is monotone and rectilinear, we prove that this bound becomes $$\\\\lfloor \\\\frac{n+4}{8} \\ floor $$⌊n+48⌋. We also present an optimal linear-time algorithm for computing the beacon kernel of P.

  17. Comparative Assessment of Blood Lead Levels of Automobile Technicians in Organised and Roadside Garages in Lagos, Nigeria

    Directory of Open Access Journals (Sweden)

    Abdulsalam Saliu

    2015-01-01

    Full Text Available Occupational exposure to lead is common among automobile technicians and constitutes 0.9% of total global health burden with a majority of cases in developing countries. The aim of this study was to determine and compare the blood lead levels of automobile technicians in roadside and organised garages in Lagos State, Nigeria. This was a comparative cross-sectional study. Data were collected using interviewer-administered questionnaires. Physical examinations were conducted and blood was analysed for lead using atomic spectrophotometery. Statistical analyses were performed to compare the median blood lead levels of each group using the independent sample (Mann-Whitney U test. Seventy-three (40.3% of the organised compared to 59 (34.3% of the roadside groups had high blood lead levels. The organised group had statistically significant higher median blood lead levels of, 66.0 µg/dL than the roadside 43.5 µg/dL (P < 0.05. There was also statistically significant association between high blood lead levels and abnormal discolouration of the mucosa of the mouth in the organised group. Automobile technicians in organised garages in Lagos have higher prevalence of elevated blood lead levels and higher median levels than the roadside group. Preventive strategies against lead exposures should be instituted by the employers and further actions should be taken to minimize exposures, improve work practices, implement engineering controls (e.g., proper ventilation, and ensure the use of personal protective equipment.

  18. Spacecraft navigation at Mars using earth-based and in situ radio tracking techniques

    Science.gov (United States)

    Thurman, S. W.; Edwards, C. D.; Kahn, R. D.; Vijayaraghavan, A.; Hastrup, R. C.; Cesarone, R. J.

    1992-08-01

    A survey of earth-based and in situ radiometric data types and results from a number of studies investigating potential radio navigation performance for spacecraft approaching/orbiting Mars and for landed spacecraft and rovers on the surface of Mars are presented. The performance of Doppler, ranging and interferometry earth-based data types involving single or multiple spacecraft is addressed. This evaluation is conducted with that of in situ data types, such as Doppler and ranging measurements between two spacecraft near Mars, or between a spacecraft and one or more surface radio beacons.

  19. Design and Implementation of Distress Prevention System using a Beacon

    Directory of Open Access Journals (Sweden)

    Lee Imsu

    2016-01-01

    Full Text Available It was proven that human accidents due to mountain climbing occupy large proportion of recently occurred man-made disasters. This paper designed and implemented an application that tells users about a variety of accidents that frequently occur in mountain and shows dynamic information about mountain climbing. It designed ‘distress prevention system using beacon’. When using beacon, it can dynamically express information without using GPS. It has advantage of supporting BLE and has little Smartphone battery consumption. The application was developed based on Android as a prototype. We expect that the application developed in this paper can contribute to the protection of precious lives by helping quick rescue in case of emergency such as distress. Manager of mountain can control data regarding the mountain climbing accident where the related functions are provided through view and user authority setup in DBMS.

  20. Beacons of discovery the worldwide science of particle physics

    CERN Document Server

    International Committee for Future Accelerators (ICFA)

    2011-01-01

    To discover what our world is made of and how it works at the most fundamental level is the challenge of particle physics. The tools of particle physics—experiments at particle accelerators and underground laboratories, together with observations of space—bring opportunities for discovery never before within reach. Thousands of scientists from universities and laboratories around the world collaborate to design, build and use unique detectors and accelerators to explore the fundamental physics of matter, energy, space and time. Together, in a common world-wide program of discovery, they provide a deep understanding of the world around us and countless benefits to society. Beacons of Discovery presents a vision of the global science of particle physics at the dawn of a new light on the mystery and beauty of the universe.

  1. BEACON: An application of nodal methods for operational support

    International Nuclear Information System (INIS)

    Boyd, W.A.; Nguyen, T.Q.

    1992-01-01

    A practical application of nodal methods is on-line plant operational support. However, to enable plant personnel to take full advantage of a nodal model to support plant operations, (a) a core nodal model must always be up to date with the current core history and conditions, (b) the nodal methods must be fast enough to allow numerous core calculations to be performed in minutes to support engineering decisions, and (c) the system must be easily accessible to engineering personnel at the reactor, their offices, or any other location considered appropriate. A core operational support package developed by Westinghouse called BEACON (best estimate analysis of core operations - nuclear) has been installed at several plants. Results from these plants and numerous in-core flux maps analyzed have demonstrated the accuracy of the model and the effectiveness of the methodology

  2. Seamless Guidance System Combining GPS, BLE Beacon, and NFC Technologies

    Directory of Open Access Journals (Sweden)

    Rung-Shiang Cheng

    2016-01-01

    Full Text Available Users rely increasingly on Location-Based Services (LBS and automated navigation/guidance systems nowadays. However, while such services are easily implemented in outdoor environments using Global Positioning System (GPS technology, a requirement still exists for accurate localization and guidance schemes in indoor settings. Accordingly, the present study proposes a system based on GPS, Bluetooth Low Energy (BLE beacons, and Near Field Communication (NFC technology. Through establishing graphic information and the design of algorithm, this study develops a guidance system for indoors and outdoors on smart phones, wishing to give user perfect smart life through this system. The proposed system is implemented on a smart phone and evaluated on a student campus environment. The experimental results confirm the ability of the proposed app to switch automatically from an outdoor mode to an indoor mode and to guide the user to requested target destination via the shortest possible route.

  3. The Radio JOVE Project - Shoestring Radio Astronomy

    Science.gov (United States)

    Thieman, J.; Flagg, R.; Greenman, W.; Higgins, C.; Reyes, F.; Sky, J.

    2010-01-01

    Radio JOVE is an education and outreach project intended to give students and other interested individuals hands-on experience in learning radio astronomy. They can do this through building a radio telescope from a relatively inexpensive kit that includes the parts for a receiver and an antenna as well as software for a computer chart recorder emulator (Radio Skypipe) and other reference materials

  4. NPP Grassland: Beacon Hill, U.K., 1972-1993, R1

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains two ASCII text files, one providing productivity measurements for a chalk grassland on Beacon Hill, West Sussex, U.K. (50.92 N, -0.85 W) and...

  5. Development of Aptamer Beacons for Antemortem Diagnosis of Chronic Wasting Disease

    National Research Council Canada - National Science Library

    Clinkenbeard, Kenneth D

    2005-01-01

    .... Once selected, the CWD aptamers will be configured as aptamer beacons that can act as molecular switches to turn "on" a novel and highly sensitive diagnostic technology termed amplifying fluorescing polymer...

  6. Development of Aptamer Beacons for Antemortem Diagnosis of Chronic Wasting Disease

    National Research Council Canada - National Science Library

    Clinkenbeard, Kenneth

    2004-01-01

    .... Once selected, the CWD aptamers will be configured as aptamer beacons that can act as molecular switches to turn on a novel and highly sensitive diagnostic technology termed amplifying fluorescing polymer. Objective...

  7. Evaluation of light-emitting diode beacon light fixtures : final report.

    Science.gov (United States)

    2009-12-01

    Rotating beacons containing filament light sources have long been used on highway maintenance trucks : to indicate the presence of the truck to other drivers. Because of advances in light-emitting diode (LED) : technologies, flashing lights containin...

  8. Highly sensitive and rapid bacteria detection using molecular beacon-Au nanoparticles hybrid nanoprobes.

    Science.gov (United States)

    Cao, Jing; Feng, Chao; Liu, Yan; Wang, Shouyu; Liu, Fei

    2014-07-15

    Since many diseases are caused by pathogenic bacterial infections, accurate and rapid detection of pathogenic bacteria is in urgent need to timely apply appropriate treatments and to reduce economic costs. To end this, we designed molecular beacon-Au nanoparticle hybrid nanoprobes to improve the bacterial detection efficiency and sensitivity. Here, we show that the designed molecular beacon modified Au nanoparticles could specifically recognize synthetic DNAs targets and can readily detect targets in clinical samples. Moreover, the hybrid nanoprobes can recognize Escherichia coli within an hour at a concentration of 10(2) cfu/ml, which is 1000-folds sensitive than using molecular beacon directly. Our results show that the molecular beacon-Au nanoparticle hybrid nanoprobes have great potential in medical and biological applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Multi-kW Uplink Fiber-Laser Beacon with Agile Signal Format, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration —  Laser beacons with scalable powers are needed for ground to deep-space optical communication uplinks. They serve as absolute reference for tracking of spacecraft...

  10. Multi-kW Uplink Fiber-Laser Beacon with Agile Signal Format, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Uplink Laser Beacons for deep-space communication, can benefit greatly from migration to the 1010-1030nm wavelengths, via use of Silicon-APDs on the spacecraft...

  11. High-throughput SNP genotyping: combining tag SNPs and molecular beacons

    CSIR Research Space (South Africa)

    Barreiro, LB

    2009-10-01

    Full Text Available In the last decade, molecular beacons have emerged to become a widely used tool in the multiplex typing of single nucleotide polymorphisms (SNPs). Improvements in detection technologies in instrumentation and chemistries to label these probes have...

  12. BEACON: A Summary Framework to Overcome Potential Reimbursement Hurdles.

    Science.gov (United States)

    Dunlop, William C N; Mullins, C Daniel; Pirk, Olaf; Goeree, Ron; Postma, Maarten J; Enstone, Ashley; Heron, Louise

    2016-10-01

    To provide a framework for addressing payers' criteria during the development of pharmaceuticals. A conceptual framework was presented to an international health economic expert panel for discussion. A structured literature search (from 2010 to May 2015), using the following databases in Ovid: Medline(®) and Medline(®) In-Process (PubMed), Embase (Ovid), EconLit (EBSCOhost) and the National Health Service Economic Evaluation Database (NHS EED), and a 'grey literature' search, were conducted to identify existing criteria from the payer perspective. The criteria assessed by existing frameworks and guidelines were collated; the most commonly reported criteria were considered for inclusion in the framework. A mnemonic was conceived as a memory aide to summarise these criteria. Overall, 41 publications were identified as potentially relevant to the objective. Following further screening, 26 were excluded upon full-text review on the basis of no framework presented (n = 13), redundancy (n = 11) or abstract only (n = 2). Frameworks that captured criteria developed for or utilised by the pharmaceutical industry (n = 5) and reimbursement guidance (n = 10) were reviewed. The most commonly identified criteria-unmet need/patient burden, safety, efficacy, quality-of-life outcomes, environment, evidence quality, budget impact and comparator-were incorporated into the summary framework. For ease of communication, the following mnemonic was developed: BEACON (Burden/target population, Environment, Affordability/value, Comparator, Outcomes, Number of studies/quality of evidence). The BEACON framework aims to capture the 'essence' of payer requirements by addressing the most commonly described criteria requested by payers regarding the introduction of a new pharmaceutical.

  13. Improving adherence to the Epic Beacon ambulatory workflow.

    Science.gov (United States)

    Chackunkal, Ellen; Dhanapal Vogel, Vishnuprabha; Grycki, Meredith; Kostoff, Diana

    2017-06-01

    Computerized physician order entry has been shown to significantly improve chemotherapy safety by reducing the number of prescribing errors. Epic's Beacon Oncology Information System of computerized physician order entry and electronic medication administration was implemented in Henry Ford Health System's ambulatory oncology infusion centers on 9 November 2013. Since that time, compliance to the infusion workflow had not been assessed. The objective of this study was to optimize the current workflow and improve the compliance to this workflow in the ambulatory oncology setting. This study was a retrospective, quasi-experimental study which analyzed the composite workflow compliance rate of patient encounters from 9 to 23 November 2014. Based on this analysis, an intervention was identified and implemented in February 2015 to improve workflow compliance. The primary endpoint was to compare the composite compliance rate to the Beacon workflow before and after a pharmacy-initiated intervention. The intervention, which was education of infusion center staff, was initiated by ambulatory-based, oncology pharmacists and implemented by a multi-disciplinary team of pharmacists and nurses. The composite compliance rate was then reassessed for patient encounters from 2 to 13 March 2015 in order to analyze the effects of the determined intervention on compliance. The initial analysis in November 2014 revealed a composite compliance rate of 38%, and data analysis after the intervention revealed a statistically significant increase in the composite compliance rate to 83% ( p < 0.001). This study supports a pharmacist-initiated educational intervention can improve compliance to an ambulatory, oncology infusion workflow.

  14. Space Telecommunications Radio System STRS Cognitive Radio

    Science.gov (United States)

    Briones, Janette C.; Handler, Louis M.

    2013-01-01

    Radios today are evolving from awareness toward cognition. A software defined radio (SDR) provides the most capability for integrating autonomic decision making ability and allows the incremental evolution toward a cognitive radio. This cognitive radio technology will impact NASA space communications in areas such as spectrum utilization, interoperability, network operations, and radio resource management over a wide range of operating conditions. NASAs cognitive radio will build upon the infrastructure being developed by Space Telecommunication Radio System (STRS) SDR technology. This paper explores the feasibility of inserting cognitive capabilities in the NASA STRS architecture and the interfaces between the cognitive engine and the STRS radio. The STRS architecture defines methods that can inform the cognitive engine about the radio environment so that the cognitive engine can learn autonomously from experience, and take appropriate actions to adapt the radio operating characteristics and optimize performance.

  15. Perancangan Prototipe Receiver Beacon Black Box Locator Acoustic 37,5 kHz Pingers

    OpenAIRE

    RUSTAMAJI RUSTAMAJI; PAULINE RAHMIATI; SARAH PERMATASARI

    2016-01-01

    ABSTRAK Ketika suatu pesawat terbang mengalami kecelakaan terjatuh ke dalam air, maka lokasi keberadaannya dapat dideteksi oleh alat yang disebut receiver beacon black box locator acoustic (pingers receiver). Pingers receiver berfungsi untuk menerima sinyal dengan frekuensi 37,5 kHz ± 1 kHz dari pingers transmitter atau Underwater Locator Beacon (ULB) yang berada pada black box pesawat. Dalam penelitian ini dibuat perancangan pingers receiver yang tersusun dari rangkaian Band Pass Filter (BPF...

  16. Serum inverts and improves the fluorescence response of an aptamer beacon to various vitamin D analytes.

    Science.gov (United States)

    Bruno, John G; Carrillo, Maria P; Phillips, Taylor; Edge, Allison

    2012-01-01

    A dominant aptamer loop structure from a library of nearly 100 candidate aptamer sequences developed against immobilized 25-hydroxyvitamin D(3) (calcidiol) was converted into a 5'-TYE 665 and 3'-Iowa black-labelled aptamer beacon. The aptamer beacon exhibited a mild 'lights on' reaction in buffer as a function of increasing concentrations of several vitamin D analogues and metabolites, with a limit of detection of approximately 200 ng/mL, and was not specific for any particular congener. In 10% or 50% human serum, the same aptamer beacon inverted its fluorescence behaviour to become a more intense 'lights off' reaction with an improved limit of detection in the range 4-16 ng/mL. We hypothesized that this drastic change in fluorescence behaviour was due to the presence of creatinine and urea in serum, which might destabilize the quenched beacon, causing an increase in fluorescence followed by decreasing fluorescence as a function of vitamin D concentrations that may bind and quench increasingly greater fractions of the denatured beacons. However, the results of several control experiments in the presence of physiological or greater concentrations of creatinine and urea, alone or combined in buffer, failed to produce the beacon fluorescence inversion. Other possible mechanistic hypotheses are also discussed. Copyright © 2011 John Wiley & Sons, Ltd.

  17. An adaptive scheme for robot localization and mapping with dynamically configurable inter-beacon range measurements.

    Science.gov (United States)

    Torres-González, Arturo; Martinez-de Dios, Jose Ramiro; Ollero, Anibal

    2014-04-25

    This work is motivated by robot-sensor network cooperation techniques where sensor nodes (beacons) are used as landmarks for range-only (RO) simultaneous localization and mapping (SLAM). This paper presents a RO-SLAM scheme that actuates over the measurement gathering process using mechanisms that dynamically modify the rate and variety of measurements that are integrated in the SLAM filter. It includes a measurement gathering module that can be configured to collect direct robot-beacon and inter-beacon measurements with different inter-beacon depth levels and at different rates. It also includes a supervision module that monitors the SLAM performance and dynamically selects the measurement gathering configuration balancing SLAM accuracy and resource consumption. The proposed scheme has been applied to an extended Kalman filter SLAM with auxiliary particle filters for beacon initialization (PF-EKF SLAM) and validated with experiments performed in the CONET Integrated Testbed. It achieved lower map and robot errors (34% and 14%, respectively) than traditional methods with a lower computational burden (16%) and similar beacon energy consumption.

  18. Supporting Beacon and Event-Driven Messages in Vehicular Platoons through Token-Based Strategies.

    Science.gov (United States)

    Balador, Ali; Uhlemann, Elisabeth; Calafate, Carlos T; Cano, Juan-Carlos

    2018-03-23

    Timely and reliable inter-vehicle communications is a critical requirement to support traffic safety applications, such as vehicle platooning. Furthermore, low-delay communications allow the platoon to react quickly to unexpected events. In this scope, having a predictable and highly effective medium access control (MAC) method is of utmost importance. However, the currently available IEEE 802.11p technology is unable to adequately address these challenges. In this paper, we propose a MAC method especially adapted to platoons, able to transmit beacons within the required time constraints, but with a higher reliability level than IEEE 802.11p, while concurrently enabling efficient dissemination of event-driven messages. The protocol circulates the token within the platoon not in a round-robin fashion, but based on beacon data age, i.e., the time that has passed since the previous collection of status information, thereby automatically offering repeated beacon transmission opportunities for increased reliability. In addition, we propose three different methods for supporting event-driven messages co-existing with beacons. Analysis and simulation results in single and multi-hop scenarios showed that, by providing non-competitive channel access and frequent retransmission opportunities, our protocol can offer beacon delivery within one beacon generation interval while fulfilling the requirements on low-delay dissemination of event-driven messages for traffic safety applications.

  19. Supporting Beacon and Event-Driven Messages in Vehicular Platoons through Token-Based Strategies

    Directory of Open Access Journals (Sweden)

    Ali Balador

    2018-03-01

    Full Text Available Timely and reliable inter-vehicle communications is a critical requirement to support traffic safety applications, such as vehicle platooning. Furthermore, low-delay communications allow the platoon to react quickly to unexpected events. In this scope, having a predictable and highly effective medium access control (MAC method is of utmost importance. However, the currently available IEEE 802.11p technology is unable to adequately address these challenges. In this paper, we propose a MAC method especially adapted to platoons, able to transmit beacons within the required time constraints, but with a higher reliability level than IEEE 802.11p, while concurrently enabling efficient dissemination of event-driven messages. The protocol circulates the token within the platoon not in a round-robin fashion, but based on beacon data age, i.e., the time that has passed since the previous collection of status information, thereby automatically offering repeated beacon transmission opportunities for increased reliability. In addition, we propose three different methods for supporting event-driven messages co-existing with beacons. Analysis and simulation results in single and multi-hop scenarios showed that, by providing non-competitive channel access and frequent retransmission opportunities, our protocol can offer beacon delivery within one beacon generation interval while fulfilling the requirements on low-delay dissemination of event-driven messages for traffic safety applications.

  20. Accelerated Adoption of Advanced Health Information Technology in Beacon Community Health Centers.

    Science.gov (United States)

    Jones, Emily; Wittie, Michael

    2015-01-01

    To complement national and state-level HITECH Act programs, 17 Beacon communities were funded to fuel community-wide use of health information technology to improve quality. Health centers in Beacon communities received supplemental funding. This article explores the association between participation in the Beacon program and the adoption of electronic health records. Using the 2010-2012 Uniform Data System, trends in health information technology adoption among health centers located within and outside of Beacon communities were explored using differences in mean t tests and multivariate logistic regression. Electronic health record adoption was widespread and rapidly growing in all health centers, especially quality improvement functionalities: structured data capture, order and results management, and clinical decision support. Adoption lagged for functionalities supporting patient engagement, performance measurement, care coordination, and public health. The use of advanced functionalities such as care coordination grew faster in Beacon health centers, and Beacon health centers had 1.7 times higher odds of adopting health records with basic safety and quality functionalities in 2010-2012. Three factors likely underlie these findings: technical assistance, community-wide activation supporting health information exchange, and the layering of financial incentives. Additional technical assistance and community-wide activation is needed to support the use of functionalities that are currently lagging. © Copyright 2015 by the American Board of Family Medicine.

  1. Radio Resource Management for V2V Discovery

    DEFF Research Database (Denmark)

    Alvarez, Beatriz Soret; Gatnau, Marta; Kovács, Istvan

    2016-01-01

    Big expectations are put into vehicular communications (V2X) for a safer and more intelligent driving. With human lives at risk, the system cannot afford to fail, which translates into very stringent reliability and latency requirements to the radio network. One of the challenges is to find...... efficient radio resource management (RRM) strategies for direct vehicle-to-vehicle (V2V) communication that can fulfil the requirements even with high traffic density. In cellular networks, a device-to-device (D2D) communication is usually split into two phases: the discovery process, for node awareness...... of each other; and the communication phase itself, where data exchange takes place. In the case of V2V, the discovery phase can utilize the status information that cars broadcast periodically as the beacons to detect the presence of neighbouring cars. For the delivery of specific messages (e...

  2. Evaluation of Physico-Chemical and Fungal Species Associated with Oil Contaminated Soil from Selected Automobile Garage in Sokoto Metropolis

    Directory of Open Access Journals (Sweden)

    Hassan Muhammad Maishanu

    2018-03-01

    Full Text Available This study was conducted with a view to evaluating the physicochemical and mycological properties of different oil contaminated soils collected from three different automobile garages in Sokoto Metropolis, and uncontaminated soil from the temporary site, Usmanu Danfodiyo University, Sokoto (UDUS was used as the control. The pH was determined using pH meter model Hanna (H1991301, quantity of mineral elements was evaluated in accordance with Murphy and Fungi were isolated from the three oil contaminated samples (A, B. and C and the uncontaminated (sample D as control, this was done by standard procedure using the method of P. Ren, T. Jankun & B. Leaderer. The physical, chemical, and mineral elements from the oil-contaminated soils of the three automobile garages and control. The results of particle soil analysis revealed the high content of sandy soil (96.2 to 87.3 and silt is the lowest with (2.5–0.6. Magnesium had the highest concentration of studied minerals, ranging from 193 to 649.2 mg/kg. while PH result revealed that the soil samples were pH value ranged from (16.85–16.20 in oil Contaminated samples, while the control had 15.90, and electrical conductivity ranged from 12.8–13.8 % and 28 % in control, four fungal isolates Aspergillus sp., Penicillum sp., Mucor sp. and Sporobolomyces sp. were identified based on colonial, sexual and morphological characteristics. These fungal strains can be used in bioremediation process and oil pollution reduction in aquatic ecosystems.

  3. The radio universe

    International Nuclear Information System (INIS)

    Worvill, R.

    1977-01-01

    Elementary description of the development of radioastronomy, radio waves from the sun and planets, the use of radio telescopes and the detection of nebulae, supernova, radio galaxies and quasars is presented. A brief glossary of terms is included. (UK)

  4. Quantum dot-based molecular beacon to monitor intracellular microRNAs.

    Science.gov (United States)

    Lee, Jonghwan; Moon, Sung Ung; Lee, Yong Seung; Ali, Bahy A; Al-Khedhairy, Abdulaziz A; Ali, Daoud; Ahmed, Javed; Al Salem, Abdullah M; Kim, Soonhag

    2015-06-02

    Fluorescence monitoring of endogenous microRNA (miRNA or miR) activity related to neuronal development using nano-sized materials provides crucial information on miRNA expression patterns in a noninvasive manner. In this study, we report a new method to monitor intracellular miRNA124a using quantum dot-based molecular beacon (R9-QD-miR124a beacon). The R9-QD-miR124a beacon was constructed using QDs and two probes, miR124a-targeting oligomer and arginine rich cell-penetrating peptide (R9 peptide). The miR124a-targeting oligomer contains a miR124a binging sequence and a black hole quencher 1 (BHQ1). In the absence of target miR124a, the R9-QD-miR124a beacon forms a partial duplex beacon and remained in quenched state because the BHQ1 quenches the fluorescence signal of the R9-QD-miR124a beacon. The binding of miR124a to the miR124a binding sequence of the miR124a-targeting oligomer triggered the separation of the BHQ1 quencher and subsequent signal-on of a red fluorescence signal. Moreover, enhanced cellular uptake was achieved by conjugation with the R9 peptide, which resulted in increased fluorescent signal of the R9-QD-miR124a beacons in P19 cells during neurogenesis due to the endogenous expression of miR124a.

  5. Quantum Dot-Based Molecular Beacon to Monitor Intracellular MicroRNAs

    Directory of Open Access Journals (Sweden)

    Jonghwan Lee

    2015-06-01

    Full Text Available Fluorescence monitoring of endogenous microRNA (miRNA or miR activity related to neuronal development using nano-sized materials provides crucial information on miRNA expression patterns in a noninvasive manner. In this study, we report a new method to monitor intracellular miRNA124a using quantum dot-based molecular beacon (R9-QD-miR124a beacon. The R9-QD-miR124a beacon was constructed using QDs and two probes, miR124a-targeting oligomer and arginine rich cell-penetrating peptide (R9 peptide. The miR124a-targeting oligomer contains a miR124a binging sequence and a black hole quencher 1 (BHQ1. In the absence of target miR124a, the R9-QD-miR124a beacon forms a partial duplex beacon and remained in quenched state because the BHQ1 quenches the fluorescence signal of the R9-QD-miR124a beacon. The binding of miR124a to the miR124a binding sequence of the miR124a-targeting oligomer triggered the separation of the BHQ1 quencher and subsequent signal-on of a red fluorescence signal. Moreover, enhanced cellular uptake was achieved by conjugation with the R9 peptide, which resulted in increased fluorescent signal of the R9-QD-miR124a beacons in P19 cells during neurogenesis due to the endogenous expression of miR124a.

  6. Optical Fiber Nanotips Coated with Molecular Beacons for DNA Detection

    Directory of Open Access Journals (Sweden)

    Ambra Giannetti

    2015-04-01

    Full Text Available Optical fiber sensors, thanks to their compactness, fast response and real-time measurements, have a large impact in the fields of life science research, drug discovery and medical diagnostics. In recent years, advances in nanotechnology have resulted in the development of nanotools, capable of entering the single cell, resulting in new nanobiosensors useful for the detection of biomolecules inside living cells. In this paper, we provide an application of a nanotip coupled with molecular beacons (MBs for the detection of DNA. The MBs were characterized by hybridization studies with a complementary target to prove their functionality both free in solution and immobilized onto a solid support. The solid support chosen as substrate for the immobilization of the MBs was a 30 nm tapered tip of an optical fiber, fabricated by chemical etching. With this set-up promising results were obtained and a limit of detection (LOD of 0.57 nM was reached, opening up the possibility of using the proposed nanotip to detect mRNAs inside the cytoplasm of living cells.

  7. Quencher-free molecular beacon tethering 7-hydroxycoumarin detects targets through protonation/deprotonation.

    Science.gov (United States)

    Kashida, Hiromu; Yamaguchi, Kyohei; Hara, Yuichi; Asanuma, Hiroyuki

    2012-07-15

    In this study, we synthesized a simple but efficient quencher-free molecular beacon tethering 7-hydroxycoumarin on D-threoninol based on its pK(a) change. The pK(a) of 7-hydroxycoumarin in a single strand was determined as 8.8, whereas that intercalated in the duplex was over 10. This large pK(a) shift (more than 1.2) upon hybridization could be attributed to the anionic and hydrophobic microenvironment inside the DNA duplex. Because 7-hydroxycoumarin quenches its fluorescence upon protonation, the emission intensity of the duplex at pH 8.5 was 1/15 that of the single strand. We applied this quenching mechanism to the preparation of a quencher-free molecular beacon by introducing the dye into the middle of the stem part. In the absence of the target, the stem region formed a duplex and fluorescence was quenched. However, when the target was added, the molecular beacon opened and the dye was deprotonated. As a result, the emission intensity of the molecular beacon with the target was 10 times higher than that without the target. Accordingly, a quencher-free molecular beacon utilizing the pK(a) change was successfully developed. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Accurate beacon positioning method for satellite-to-ground optical communication.

    Science.gov (United States)

    Wang, Qiang; Tong, Ling; Yu, Siyuan; Tan, Liying; Ma, Jing

    2017-12-11

    In satellite laser communication systems, accurate positioning of the beacon is essential for establishing a steady laser communication link. For satellite-to-ground optical communication, the main influencing factors on the acquisition of the beacon are background noise and atmospheric turbulence. In this paper, we consider the influence of background noise and atmospheric turbulence on the beacon in satellite-to-ground optical communication, and propose a new locating algorithm for the beacon, which takes the correlation coefficient obtained by curve fitting for image data as weights. By performing a long distance laser communication experiment (11.16 km), we verified the feasibility of this method. Both simulation and experiment showed that the new algorithm can accurately obtain the position of the centroid of beacon. Furthermore, for the distortion of the light spot through atmospheric turbulence, the locating accuracy of the new algorithm was 50% higher than that of the conventional gray centroid algorithm. This new approach will be beneficial for the design of satellite-to ground optical communication systems.

  9. A spiral wave front beacon for underwater navigation: transducer prototypes and testing.

    Science.gov (United States)

    Dzikowicz, Benjamin R; Hefner, Brian T

    2012-05-01

    Transducers for acoustic beacons which can produce outgoing signals with wave fronts whose horizontal cross sections are circular or spiral are studied experimentally. A remote hydrophone is used to determine its aspect relative to the transducers by comparing the phase of the circular signal to the phase of the spiral signal. The transducers for a "physical-spiral" beacon are made by forming a strip of 1-3 piezocomposite transducer material around either a circular or spiral backing. A "phased-spiral" beacon is made from an array of transducer elements which can be driven either in phase or staggered out of phase so as to produce signals with either a circular or spiral wave front. Measurements are made to study outgoing signals and their usefulness in determining aspect angle. Vertical beam width is also examined and phase corrections applied when the hydrophone is out of the horizontal plane of the beacon. While numerical simulations indicate that the discontinuity in the physical-spiral beacon introduces errors into the measured phase, damping observed at the ends of the piezocomposite material is a more significant source of error. This damping is also reflected in laser Doppler vibrometer measurements of the transducer's surface velocity.

  10. Adaptive Beaconing in Mobility Aware Clustering Based MAC Protocol for Safety Message Dissemination in VANET

    Directory of Open Access Journals (Sweden)

    Nishu Gupta

    2017-01-01

    Full Text Available Majority of research contributions in wireless access in vehicular environment (WAVE/IEEE 802.11p standard focus on life critical safety-related applications. These applications require regular status update of vehicle’s position referred to as beaconing. Periodic beaconing in vehicle to vehicle communication leads to severe network congestion in the communication channel. The condition worsens under high vehicular density where it impacts reliability and upper bound latency of safety messages. In this paper, WAVE compliant enhancement to the existing IEEE 802.11p protocol is presented which targets prioritized delivery of safety messages while simultaneously provisioning the dissemination of nonsafety messages. Proposed scheme relies on dynamic generation of beacons to mitigate channel congestion and inefficient bandwidth utilization by reducing transmission frequency of beacons. Through the use of clustering mechanism, different beaconing frequencies and different data transmission rates are assigned to prioritize vehicular mobility. Through extensive simulation results, the performance of the proposed approach is evaluated in terms of a wide range of quality of service (QoS parameters for two different transmission ranges. Results show that the proposed protocol provides significant enhancement and stability of the clustered topology in vehicular ad hoc network over existing standard and other protocols with similar applications.

  11. A Measurement Study of BLE iBeacon and Geometric Adjustment Scheme for Indoor Location-Based Mobile Applications

    Directory of Open Access Journals (Sweden)

    Jeongyeup Paek

    2016-01-01

    Full Text Available Bluetooth Low Energy (BLE and the iBeacons have recently gained large interest for enabling various proximity-based application services. Given the ubiquitously deployed nature of Bluetooth devices including mobile smartphones, using BLE and iBeacon technologies seemed to be a promising future to come. This work started off with the belief that this was true: iBeacons could provide us with the accuracy in proximity and distance estimation to enable and simplify the development of many previously difficult applications. However, our empirical studies with three different iBeacon devices from various vendors and two types of smartphone platforms prove that this is not the case. Signal strength readings vary significantly over different iBeacon vendors, mobile platforms, environmental or deployment factors, and usage scenarios. This variability in signal strength naturally complicates the process of extracting an accurate location/proximity estimation in real environments. Our lessons on the limitations of iBeacon technique lead us to design a simple class attendance checking application by performing a simple form of geometric adjustments to compensate for the natural variations in beacon signal strength readings. We believe that the negative observations made in this work can provide future researchers with a reference on how well of a performance to expect from iBeacon devices as they enter their system design phases.

  12. Improved margin utilization through the use of beacon power distribution surveillance

    International Nuclear Information System (INIS)

    Miller, R. Wade; Boyd, William A.

    2002-01-01

    Core Operations, including fuel cycle costs, can be significantly improved when state of the art surveillance techniques are employed for core power distribution monitoring. Core power distribution monitoring and Technical Specification surveillance are major operational issues at PWR's, particularly in plants with movable in core detectors. Even plants with fixed in core detectors do not always make use of the continuous data that is available. The BEACON TM system (Best Estimate Analysis of Core Operations - Nuclear) is a core monitoring and operational support package developed by Westinghouse for use in PWR plants with fixed or movable in core detectors. BEACON is a real time core monitoring system, which uses existing core instrumentation data and an on-line neutronics model to provide continuous monitored of the core power distribution information. With this information available the BEACON system can be used to continuously monitor core power margin for the plant Tech Spec surveillance requirements and for plant operational guidance

  13. Efficient Beacon Collision Resolution Procedure for IEEE 802.15.4 /Zigbee Wireless Personal Area Networks

    Directory of Open Access Journals (Sweden)

    Bassam A. Zafar

    2017-04-01

    Full Text Available While IEEE 802.15.4/Zigbee is a promising technology for Wireless Personal Area Networks, several transmission problems are not yet resolved. In particular, the problem of beacon transmission interferences is causing the device connection loss to the network. In order to resolve this problem, we present a new distributed and reactive procedure for beacon collision resolution. It is an extension of the alignment procedure to reorganize randomly the beacon transmission time when a collision has occurred. The detail of the proposed procedure will be fully described and analyzed. The performance of our approach is performed by simulations. The results show that our approach reduces the collision probability and the device disconnections consequently.

  14. A beacon interval shifting scheme for interference mitigation in body area networks.

    Science.gov (United States)

    Kim, Seungku; Kim, Seokhwan; Kim, Jin-Woo; Eom, Doo-Seop

    2012-01-01

    This paper investigates the issue of interference avoidance in body area networks (BANs). IEEE 802.15 Task Group 6 presented several schemes to reduce such interference, but these schemes are still not proper solutions for BANs. We present a novel distributed TDMA-based beacon interval shifting scheme that reduces interference in the BANs. A design goal of the scheme is to avoid the wakeup period of each BAN coinciding with other networks by employing carrier sensing before a beacon transmission. We analyze the beacon interval shifting scheme and investigate the proper back-off length when the channel is busy. We compare the performance of the proposed scheme with the schemes presented in IEEE 802.15 Task Group 6 using an OMNeT++ simulation. The simulation results show that the proposed scheme has a lower packet loss, energy consumption, and delivery-latency than the schemes of IEEE 802.15 Task Group 6.

  15. Analyte-Triggered DNA-Probe Release from a Triplex Molecular Beacon for Nanopore Sensing.

    Science.gov (United States)

    Guo, Bingyuan; Sheng, Yingying; Zhou, Ke; Liu, Quansheng; Liu, Lei; Wu, Hai-Chen

    2018-03-26

    A new nanopore sensing strategy based on triplex molecular beacon was developed for the detection of specific DNA or multivalent proteins. The sensor is composed of a triplex-forming molecular beacon and a stem-forming DNA component that is modified with a host-guest complex. Upon target DNA hybridizing with the molecular beacon loop or multivalent proteins binding to the recognition elements on the stem, the DNA probe is released and produces highly characteristic current signals when translocated through α-hemolysin. The frequency of current signatures can be used to quantify the concentrations of the target molecules. This sensing approach provides a simple, quick, and modular tool for the detection of specific macromolecules with high sensitivity and excellent selectivity. It may find useful applications in point-of-care diagnostics with a portable nanopore kit in the future. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Development of satellite position location system for aircraft and boat distress beacons

    Science.gov (United States)

    Kahle, D. R.

    1982-01-01

    An international satellite system for the detection and location of distress beacons carried on aircraft and vessels is in its technical checkout phase. User demonstration and evaluation (D&E) will start in early 1983 and continue for two years. The D&E phase and a subsequent transition period will form the basis for improved search and rescue operations for the 1980's and beyond. The system, called COSPAS/SARSAT, has international participation involving the U.S., Canada, and France as SARSAT members and joint participation with the Soviet Union's COSPAS Project. Norway and the U.K. have recently joined as investigators. Average position location error of the satellite aided processing is expected to be from 10-20KM for the existing 121.5/243 MHz distress beacons and from 2-5KM for experimental beacons transmitting in the 406 MHz band.

  17. Analysis of the Causes of Cracks in the Bottom Floor of the Underground Garage of the Hefei Government Affairs Center by using 3D Finite-Element Analysis

    Directory of Open Access Journals (Sweden)

    ZHU Lei

    2015-09-01

    Full Text Available A three-dimensional finite-element software program is used in this study to analyze the causes of cracks in an underground garage. Numerous cracks, serious and regular alike, can be found in the underground garage of the Hefei Government Affairs Center. These cracks are mainly located around the central part of the bottom floor within a 44.6– 57.8 m radius. To explore the causes of the cracks, two attempts are made. On one hand, on-site crack detection and underground water monitoring are conducted. On the other hand, the finite-element software program ANSYS is adopted to establish a finite-element model for the floor–foundation and connecting beam–foundation soil systems of the underground garage. Furthermore, the influences of the underground foundation, underground water level, soil expansion, and Poisson ratio on the bottom floor are calculated and analyzed. On the basis of the calculation and monitoring results, the following conclusion can be made: underground water is the main cause of the bottom floor cracks because underground water exerts a pushing force from the bottom and causes the expansibility of expansive soil. The study aims to provide a theoretical basis for the treatment of cracking in the Hefei Government Affairs Center, and offer a reference for the design, construction, and maintenance of similar projects.

  18. Development of an aptamer beacon for detection of interferon-gamma.

    Science.gov (United States)

    Tuleuova, Nazgul; Jones, Caroline N; Yan, Jun; Ramanculov, Erlan; Yokobayashi, Yohei; Revzin, Alexander

    2010-03-01

    Traditional antibody-based affinity sensing strategies employ multiple reagents and washing steps and are unsuitable for real-time detection of analyte binding. Aptamers, on the other hand, may be designed to monitor binding events directly, in real-time, without the need for secondary labels. The goal of the present study was to design an aptamer beacon for fluorescence resonance energy transfer (FRET)-based detection of interferon-gamma (IFN-gamma)--an important inflammatory cytokine. Variants of DNA aptamer modified with biotin moieties and spacers were immobilized on avidin-coated surfaces and characterized by surface plasmon resonance (SPR). The SPR studies showed that immobilization of aptamer via the 3' end resulted in the best binding IFN-gamma (K(d) = 3.44 nM). This optimal aptamer variant was then used to construct a beacon by hybridizing fluorophore-labeled aptamer with an antisense oligonucleotide strand carrying a quencher. SPR studies revealed that IFN-gamma binding with an aptamer beacon occurred within 15 min of analyte introduction--suggesting dynamic replacement of the quencher-complementary strand by IFN-gamma molecules. To further highlight biosensing applications, aptamer beacon molecules were immobilized inside microfluidic channels and challenged with varying concentration of analyte. Fluorescence microscopy revealed low fluorescence in the absence of analyte and high fluorescence after introduction of IFN-gamma. Importantly, unlike traditional antibody-based immunoassays, the signal was observed directly upon binding of analyte without the need for multiple washing steps. The surface immobilized aptamer beacon had a linear range from 5 to 100 nM and a lower limit of detection of 5 nM IFN-gamma. In conclusion, we designed a FRET-based aptamer beacon for monitoring of an inflammatory cytokine-IFN-gamma. In the future, this biosensing strategy will be employed to monitor dynamics of cytokine production by the immune cells.

  19. Building and strengthening infrastructure for data exchange: lessons from the beacon communities.

    Science.gov (United States)

    Torres, Gretchen W; Swietek, Karen; Ubri, Petry S; Singer, Rachel F; Lowell, Kristina H; Miller, Wilhelmine

    2014-01-01

    The Beacon Community Cooperative Agreement Program supports interventions, including care-delivery innovations, provider performance measurement and feedback initiatives, and tools for providers and consumers to enhance care. Using a learning health system framework, we examine the Beacon Communities' processes in building and strengthening health IT (HIT) infrastructures, specifically successes and challenges in sharing patient information to improve clinical care. In 2010, the Office of the National Coordinator for Health Information Technology (ONC) launched the three-year program, which provided $250 million to 17 Beacon Communities to invest in HIT and health information exchange (HIE) infrastructure. Beacon Communities used this funding to develop and disseminate HIT-enabled quality improvement practices found effective in particular community and practice environments. NORC conducted 7 site visits, November 2012-March 2013, selecting Communities to represent diverse program features. From August-October 2013, NORC held discussions with the remaining 10 Communities. Following each visit or discussion, NORC summarized the information gathered, including transcripts, team observations, and other documents the Community provided, to facilitate a within-Community analysis of context and stakeholders, intervention strategies, enabling factors, and challenges. Although each Community designed and implemented data-sharing strategies in a unique environment, similar challenges and enabling factors emerged across the Beacons. From a learning health system perspective, their strategies to build and strengthen data-sharing infrastructures address the following crosscutting priorities: promoting technical advances and innovations by helping providers adapt EHRs for data exchange and performance measurement with customizable IT and offering technical support to smaller, independent providers; engaging key stakeholders; and fostering transparent governance and stewardship

  20. Time-Resolved Nucleic Acid Hybridization Beacons Utilizing Unimolecular and Toehold-Mediated Strand Displacement Designs.

    Science.gov (United States)

    Massey, Melissa; Ancona, Mario G; Medintz, Igor L; Algar, W Russ

    2015-12-01

    Nucleic acid hybridization probes are sought after for numerous assay and imaging applications. These probes are often limited by the properties of fluorescent dyes, prompting the development of new probes where dyes are paired with novel or nontraditional luminescent materials. Luminescent terbium complexes are an example of such a material, and these complexes offer several unique spectroscopic advantages. Here, we demonstrate two nonstem-loop designs for light-up nucleic acid hybridization beacons that utilize time-resolved Förster resonance energy transfer (TR-FRET) between a luminescent Lumi4-Tb cryptate (Tb) donor and a fluorescent reporter dye, where time-resolved emission from the dye provides an analytical signal. Both designs are based on probe oligonucleotides that are labeled at their opposite termini with Tb and a fluorescent reporter dye. In one design, a probe is partially blocked with a quencher dye-labeled oligonucleotide, and target hybridization is signaled through toehold-mediated strand displacement and loss of a competitive FRET pathway. In the other design, the intrinsic folding properties of an unblocked probe are utilized in combination with a temporal mechanism for signaling target hybridization. This temporal mechanism is based on a recently elucidated "sweet spot" for TR-FRET measurements and exploits distance control over FRET efficiencies to shift the Tb lifetime within or outside the time-gated detection window for measurements. Both the blocked and unblocked beacons offer nanomolar (femtomole) detection limits, response times on the order of minutes, multiplexing through the use of different reporter dyes, and detection in complex matrices such as serum and blood. The blocked beacons offer better mismatch selectivity, whereas the unblocked beacons are simpler in design. The temporal mechanism of signaling utilized with the unblocked beacons also plays a significant role with the blocked beacons and represents a new and effective

  1. Molecular beacon anchored onto a graphene oxide substrate

    Science.gov (United States)

    Darbandi, Arash; Datta, Debopam; Patel, Krunal; Lin, Gary; Stroscio, Michael A.; Dutta, Mitra

    2017-09-01

    In this article, we report a graphene oxide-based nanosensor incorporating semiconductor quantum dots linked to DNA-aptamers that functions as a ‘turn-off’ fluorescent nanosensor for detection of low concentrations of analytes. A specific demonstration of this turn-off aptasensor is presented for the case of the detection of mercury (II) ions. In this system, ensembles of aptamer-based quantum-dot sensors are anchored onto graphene oxide (GO) flakes which provide a platform for analyte detection in the vicinity of GO. Herein, the operation of this ensemble-based nanosensor is demonstrated for mercury ions, which upon addition of mercury, quenching of the emission intensity from the quantum dots is observed due to resonance energy transfer between quantum dots and the gold nanoparticle connected via a mercury target aptamer. A key result is that the usually dominant effect of quenching of the quantum dot due to close proximity to the GO can be reduced to negligible levels by using a linker molecule in conjunctions with the aptamer-based nanosensor. The effect of ionic concentration of the background matrix on the emission intensity was also investigated. The sensor system is found to be highly selective towards mercury and exhibits a linear behavior (r 2 > 0.99) in the nanomolar concentration range. The detection limit of the sensor towards mercury with no GO present was found to be 16.5 nM. With GO attached to molecular beacon via 14 base, 35 base, and 51 base long linker DNA, the detection limit was found to be 38.4 nM, 9.45 nM, and 11.38 nM; respectively.

  2. Experience and evaluation of advanced on-line core monitoring system 'BEACON' at IKATA site

    International Nuclear Information System (INIS)

    Fujitsuka, Nobumichi; Tanouchi, Hideyuki; Imamura, Yasuhiro; Mizobuchil, Daisuke

    1997-01-01

    Shikoku Electric Power Company installed BEACON core monitoring system into IKATA unit 3 in May 1994. During its first cycle of core operation, various operational data were obtained including data of some anomalous reactor conditions introduced for the test objective of the plant start-up. This paper presents the evaluation of the BEACON system capability based on this experience. The system functions such as core monitoring and anomaly detection, prediction of future reactor conditions and increased efficiency of core management activities are discussed. Our future plan to utilize the system is also presented. (authors)

  3. Code Development and Analysis Program: developmental checkout of the BEACON/MOD2A code

    International Nuclear Information System (INIS)

    Ramsthaler, J.A.; Lime, J.F.; Sahota, M.S.

    1978-12-01

    A best-estimate transient containment code, BEACON, is being developed by EG and G Idaho, Inc. for the Nuclear Regulatory Commission's reactor safety research program. This is an advanced, two-dimensional fluid flow code designed to predict temperatures and pressures in a dry PWR containment during a hypothetical loss-of-coolant accident. The most recent version of the code, MOD2A, is presently in the final stages of production prior to being released to the National Energy Software Center. As part of the final code checkout, seven sample problems were selected to be run with BEACON/MOD2A

  4. Optimal placement of range-only beacons for mobile robot localisation

    CSIR Research Space (South Africa)

    Burke, Michael G

    2011-11-01

    Full Text Available of the Euclidean distance between the position estimate (x; y; z) and the largest orthogo- nal standard deviations in 3D space, and is an improvement on the GDOP metric as it considers both off-diagonal covariance terms and individual beacon noise. The beacon... is the Euclidean distance between an accessed node and a goal. This results in the shortest route to a goal being determined. The cost of traversing to a node is typically the distance between nodes. However, by replacing this cost with the uncertainty metric...

  5. Molecular beacon – tool for real time studying gene activity in stem cells

    DEFF Research Database (Denmark)

    Ilieva, Mirolyuba; Dufva, Martin

    Cells respond to their internal genetic programs and external stimuli by modulating the synthesis of specific mRNAs. Direct observation of mRNA expression in living cells can provide valuable information with regards to understanding fundamental processes such cell differentiation, regeneration...... and cancerogenesis. Molecular beacon technology is based on fluorescence resonance energy transfer (FRET) and the complementary pairing principles. These fluorescent molecular probes are highly specific and sensitive and are one important tool in in vitro diagnostics. Here molecular beacons are used to follow...

  6. Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers

    Science.gov (United States)

    The Pierre Auger Collaboration

    2016-01-01

    To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used to cross-check that indeed we reach a nanosecond-scale timing accuracy by this correction. First, we operate a ``beacon transmitter'' which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.

  7. Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers

    International Nuclear Information System (INIS)

    Aab, A.; Abreu, P.; Aglietta, M.; Ahn, E.J.; Al Samarai, I.; Albuquerque, I.F.M.; Allekotte, I.; Allison, P.; Almela, A.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Alves Batista, R.; Ambrosio, M.; Aminaei, A.

    2016-01-01

    To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used to cross-check that indeed we reach a nanosecond-scale timing accuracy by this correction. First, we operate a ''beacon transmitter'' which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA

  8. Improving Indoor Localization Using Bluetooth Low Energy Beacons

    Directory of Open Access Journals (Sweden)

    Pavel Kriz

    2016-01-01

    Full Text Available The paper describes basic principles of a radio-based indoor localization and focuses on the improvement of its results with the aid of a new Bluetooth Low Energy technology. The advantage of this technology lies in its support by contemporary mobile devices, especially by smartphones and tablets. We have implemented a distributed system for collecting radio fingerprints by mobile devices with the Android operating system. This system enables volunteers to create radio-maps and update them continuously. New Bluetooth Low Energy transmitters (Apple uses its “iBeacon” brand name for these devices have been installed on the floor of the building in addition to existing WiFi access points. The localization of stationary objects based on WiFi, Bluetooth Low Energy, and their combination has been evaluated using the data measured during the experiment in the building. Several configurations of the transmitters’ arrangement, several ways of combination of the data from both technologies, and other parameters influencing the accuracy of the stationary localization have been tested.

  9. Geologic map of the Beacon Rock quadrangle, Skamania County, Washington

    Science.gov (United States)

    Evarts, Russell C.; Fleck, Robert J.

    2017-06-06

    The Beacon Rock 7.5′ quadrangle is located approximately 50 km east of Portland, Oregon, on the north side of the Columbia River Gorge, a scenic canyon carved through the axis of the Cascade Range by the Columbia River. Although approximately 75,000 people live within the gorge, much of the region remains little developed and is encompassed by the 292,500-acre Columbia River Gorge National Scenic Area, managed by a consortium of government agencies “to pro­tect and provide for the enhancement of the scenic, cultural, recreational and natural resources of the Gorge and to protect and support the economy of the Columbia River Gorge area.” As the only low-elevation corridor through the Cascade Range, the gorge is a critical regional transportation and utilities corridor (Wang and Chaker, 2004). Major state and national highways and rail lines run along both shores of the Columbia River, which also provides important water access to ports in the agricultural interior of the Pacific Northwest. Transmission lines carry power from hydroelectric facilities in the gorge and farther east to the growing urban areas of western Oregon and Washington, and natural-gas pipelines transect the corridor (Wang and Chaker, 2004). These lifelines are highly vulnerable to disruption by earthquakes, landslides, and floods. A major purpose of the work described here is to identify and map geologic hazards, such as faults and landslide-prone areas, to provide more accurate assessments of the risks associated with these features.The steep canyon walls of the map area reveal exten­sive outcrops of Miocene flood-basalt flows of the Columbia River Basalt Group capped by fluvial deposits of the ances­tral Columbia River, Pliocene lavas erupted from the axis of the Cascade arc to the east, and volcanic rocks erupted from numerous local vents. The Columbia River Basalt Group unconformably rests on a sequence of late Oligocene and early Miocene rocks of the ancestral Cascade volcanic arc

  10. ClassBeacons: designing distributed visualization of teachers’ physical proximity in the classroom.

    NARCIS (Netherlands)

    An, P.; Bakker, S.; Ordanovski, S.; Taconis, R.; Eggen, J.H.

    2018-01-01

    Pengcheng An, Saskia Bakker, Sara Ordanovski, Ruurd Taconis, Berry Eggen. 2018 (accepted at Oct 2017). ClassBeacons: designing distributed visualization of teachers’ physical proximity in the classroom. In Proceedings of Tangible and Embodied Interaction, TEI 2018, Mar 18-21, 2018,

  11. Pedestrian hybrid beacon crosswalk system (PHB) or high-intensity activated crosswalk (HAWK).

    Science.gov (United States)

    2014-11-01

    The Pedestrian Hybrid Beacon Crosswalk (PHB) is a type of traffic control system, used to aid : pedestrians safely crossing the street and to regulate traffic flow. This study examines the : success of the first PHB installed in the state of Vermont....

  12. Beacon satellite studies and modelling of total electron contents of the ionosphere

    International Nuclear Information System (INIS)

    Tyagi, T.R.

    1990-01-01

    An attempt is made to highlight some of the beacon satellite studies, particularly those relating to total electron content (TEC) and scintillations, with special attention to Indian subcontinent observations. The modelling of TEC is described. The scope of new experiments for specific problem is indicated. (author). 78 refs., 12 figs

  13. Improved fixation quality provided by a Bessel beacon in an adaptive optics system.

    Science.gov (United States)

    Lambert, Andrew J; Daly, Elizabeth M; Dainty, Christopher J

    2013-07-01

    We investigate whether a structured probe beam that creates the beacon for use in a retinal imaging adaptive optics system can provide useful side effects. In particular we investigate whether a Bessel beam that is seen by the subject as a set of concentric rings has a dampening effect on fixation variations of the subject under observation. This calming effect would allow longer periods of observation, particularly for patients with abnormal fixation. An experimental adaptive optics system developed for retinal imaging is used to monitor the fluctuations in aberrations for artificial and human subjects. The probe beam is alternated between a traditional beacon and one provided by a Bessel beam created by SLM. Time-frequency analysis is used to indicate the differences in power and time variation during fixation depending on whether the Bessel beam or the traditional beacon is employed. Comparison is made with the response for an artificial eye to discount systemic variations. Significant evidence is accrued to indicate the reduced fluctuations in fixation when the Bessel beam is employed to create the beacon. © 2013 The Authors Ophthalmic & Physiological Optics © 2013 The College of Optometrists.

  14. The Effects of a Rectangular Rapid-Flashing Beacon on Vehicle Speed

    Science.gov (United States)

    VanWagner, Michelle; Van Houten, Ron; Betts, Brian

    2011-01-01

    In 2008, nearly 31% of vehicle fatalities were related to failure to adhere to safe vehicle speeds (National Highway Traffic Safety Administration [NHTSA], 2009). The current study evaluated the effect of a rectangular rapid-flashing beacon (RRFB) triggered by excessive speed on vehicle speed using a combined alternating treatments and reversal…

  15. Beacon-Based Service Publishing Framework in Multiservice Wi-Fi Hotspots

    Directory of Open Access Journals (Sweden)

    Di Sorte Dario

    2007-01-01

    Full Text Available In an expected future multiaccess and multiservice IEEE 802.11 environment, the problem of providing users with useful service-related information to support a correct rapid network selection is expected to become a very important issue. A feasible short-term 802.11-tailored working solution, compliant with existing equipment, is to publish service information encoded within the SSID information element within beacon frames. This makes it possible for an operator to implement service publishing in 802.11 networks while waiting for a standardized mechanism. Also, this straightforward approach has allowed us to evaluate experimentally the performance of a beacon-based service publishing solution. In fact, the main focus of the paper is indeed to present a quantitative comparison of service discovery times between the legacy scenario, where the user is forced to associate and authenticate with a network point of access to check its service offer, and the enhanced scenario where the set of service-related information is broadcasted within beacons. These discovery times are obtained by processing the results of a measurement campaign performed in a multiaccess/service 802.11 environment. This analysis confirms the effectiveness of the beacon-based approach. We also show that the cost in terms of wireless bandwidth consumption of such solution is low.

  16. Application of the BEACON-TSM system to the operation of PWR reactors

    International Nuclear Information System (INIS)

    Lozano, J. A.; Mildrum, C.; Serrano, J. F.

    2011-01-01

    BEACON-TSM is an advanced system of the operation support of PWR reactors that combines the capabilities of an advanced nodal neutronic model and the measures of the instrumentation available in plant to determine, accurately and continuously, the distribution of power in the core and the available margins to the limits of the beak factors.

  17. Beacon signal in transcranial color coded ultrasound: A sign for brain death

    Directory of Open Access Journals (Sweden)

    Mehmet Akif Topçuoğlu

    2014-04-01

    Full Text Available A widely under-recognized brain-death confirming transcranial ultrasonography pattern resembling the red-blue beacon signal was demonstrated. Familiarity to this distinct and characteristic ultrasonic pattern seems to be important in the perspective of point-of-care neurological ultrasound use and knobology.

  18. Sequential strand displacement beacon for detection of DNA coverage on functionalized gold nanoparticles.

    Science.gov (United States)

    Paliwoda, Rebecca E; Li, Feng; Reid, Michael S; Lin, Yanwen; Le, X Chris

    2014-06-17

    Functionalizing nanomaterials for diverse analytical, biomedical, and therapeutic applications requires determination of surface coverage (or density) of DNA on nanomaterials. We describe a sequential strand displacement beacon assay that is able to quantify specific DNA sequences conjugated or coconjugated onto gold nanoparticles (AuNPs). Unlike the conventional fluorescence assay that requires the target DNA to be fluorescently labeled, the sequential strand displacement beacon method is able to quantify multiple unlabeled DNA oligonucleotides using a single (universal) strand displacement beacon. This unique feature is achieved by introducing two short unlabeled DNA probes for each specific DNA sequence and by performing sequential DNA strand displacement reactions. Varying the relative amounts of the specific DNA sequences and spacing DNA sequences during their coconjugation onto AuNPs results in different densities of the specific DNA on AuNP, ranging from 90 to 230 DNA molecules per AuNP. Results obtained from our sequential strand displacement beacon assay are consistent with those obtained from the conventional fluorescence assays. However, labeling of DNA with some fluorescent dyes, e.g., tetramethylrhodamine, alters DNA density on AuNP. The strand displacement strategy overcomes this problem by obviating direct labeling of the target DNA. This method has broad potential to facilitate more efficient design and characterization of novel multifunctional materials for diverse applications.

  19. A Beacon Transmission Power Control Algorithm Based on Wireless Channel Load Forecasting in VANETs.

    Science.gov (United States)

    Mo, Yuanfu; Yu, Dexin; Song, Jun; Zheng, Kun; Guo, Yajuan

    2015-01-01

    In a vehicular ad hoc network (VANET), the periodic exchange of single-hop status information broadcasts (beacon frames) produces channel loading, which causes channel congestion and induces information conflict problems. To guarantee fairness in beacon transmissions from each node and maximum network connectivity, adjustment of the beacon transmission power is an effective method for reducing and preventing channel congestion. In this study, the primary factors that influence wireless channel loading are selected to construct the KF-BCLF, which is a channel load forecasting algorithm based on a recursive Kalman filter and employs multiple regression equation. By pre-adjusting the transmission power based on the forecasted channel load, the channel load was kept within a predefined range; therefore, channel congestion was prevented. Based on this method, the CLF-BTPC, which is a transmission power control algorithm, is proposed. To verify KF-BCLF algorithm, a traffic survey method that involved the collection of floating car data along a major traffic road in Changchun City is employed. By comparing this forecast with the measured channel loads, the proposed KF-BCLF algorithm was proven to be effective. In addition, the CLF-BTPC algorithm is verified by simulating a section of eight-lane highway and a signal-controlled urban intersection. The results of the two verification process indicate that this distributed CLF-BTPC algorithm can effectively control channel load, prevent channel congestion, and enhance the stability and robustness of wireless beacon transmission in a vehicular network.

  20. A Beacon Transmission Power Control Algorithm Based on Wireless Channel Load Forecasting in VANETs.

    Directory of Open Access Journals (Sweden)

    Yuanfu Mo

    Full Text Available In a vehicular ad hoc network (VANET, the periodic exchange of single-hop status information broadcasts (beacon frames produces channel loading, which causes channel congestion and induces information conflict problems. To guarantee fairness in beacon transmissions from each node and maximum network connectivity, adjustment of the beacon transmission power is an effective method for reducing and preventing channel congestion. In this study, the primary factors that influence wireless channel loading are selected to construct the KF-BCLF, which is a channel load forecasting algorithm based on a recursive Kalman filter and employs multiple regression equation. By pre-adjusting the transmission power based on the forecasted channel load, the channel load was kept within a predefined range; therefore, channel congestion was prevented. Based on this method, the CLF-BTPC, which is a transmission power control algorithm, is proposed. To verify KF-BCLF algorithm, a traffic survey method that involved the collection of floating car data along a major traffic road in Changchun City is employed. By comparing this forecast with the measured channel loads, the proposed KF-BCLF algorithm was proven to be effective. In addition, the CLF-BTPC algorithm is verified by simulating a section of eight-lane highway and a signal-controlled urban intersection. The results of the two verification process indicate that this distributed CLF-BTPC algorithm can effectively control channel load, prevent channel congestion, and enhance the stability and robustness of wireless beacon transmission in a vehicular network.

  1. Analysis and Enhancement of IEEE 802.15.4e DSME Beacon Scheduling Model

    Directory of Open Access Journals (Sweden)

    Kwang-il Hwang

    2014-01-01

    Full Text Available In order to construct a successful Internet of things (IoT, reliable network construction and maintenance in a sensor domain should be supported. However, IEEE 802.15.4, which is the most representative wireless standard for IoT, still has problems in constructing a large-scale sensor network, such as beacon collision. To overcome some problems in IEEE 802.15.4, the 15.4e task group proposed various different modes of operation. Particularly, the IEEE 802.15.4e deterministic and synchronous multichannel extension (DSME mode presents a novel scheduling model to solve beacon collision problems. However, the DSME model specified in the 15.4e draft does not present a concrete design model but a conceptual abstract model. Therefore, in this paper we introduce a DSME beacon scheduling model and present a concrete design model. Furthermore, validity and performance of DSME are evaluated through experiments. Based on experiment results, we analyze the problems and limitations of DSME, present solutions step by step, and finally propose an enhanced DSME beacon scheduling model. Through additional experiments, we prove the performance superiority of enhanced DSME.

  2. Scheduled MAC in Beacon Overlay Networks for Underwater Localization and Time-Synchronization

    NARCIS (Netherlands)

    van Kleunen, W.A.P.; Meratnia, Nirvana; Havinga, Paul J.M.

    2011-01-01

    In this article we introduce a MAC protocol designed for underwater localization and time-synchronisation. The MAC protocol assumes a network of static reference nodes and allows blind nodes to be localized by listening-only to the beacon messages. Such a system is known to be very scalable. We show

  3. Visual detection of STAT5B gene expression in living cell using the hairpin DNA modified gold nanoparticle beacon.

    Science.gov (United States)

    Xue, Jianpeng; Shan, Lingling; Chen, Haiyan; Li, Yang; Zhu, Hongyan; Deng, Dawei; Qian, Zhiyu; Achilefu, Samuel; Gu, Yueqing

    2013-03-15

    Signal transducer and activator of transcription 5B (STAT5B) is an important protein in JAK-STAT signaling pathway that is responsible for the metastasis and proliferation of tumor cells. Determination of the STAT5B messenger Ribonucleic Acid (mRNA) relating to the STAT5B expression provides insight into the mechanism of tumor progression. In this study, we designed and used a special hairpin deoxyribonucleic acid (DNA) for human STAT5B mRNA to functionalize gold nanoparticles, which served as a beacon for detecting human STAT5B expression. Up to 90% quenching efficiency was achieved. Upon hybridizing with the target mRNA, the hairpin DNA modified gold nanoparticle beacons (hDAuNP beacons) release the fluorophores attached at 5' end of the oligonucleotide sequence. The fluorescence properties of the beacon before and after the hybridization with the complementary DNA were confirmed in vitro. The stability of hDAuNP beacons against degradation by DNase I and GSH indicated that the prepared beacon is stable inside cells. The detected fluorescence in MCF-7 cancer cells correlates with the specific STAT5B mRNA expression, which is consistent with the result from PCR measurement. Fluorescence microscopy showed that the hDAuNP beacons internalized in cells without using transfection agents, with intracellular distribution in the cytoplasm rather than the nucleus. The results demonstrated that this beacon could directly provide quantitative measurement of the intracellular STAT5B mRNA in living cells. Compared to the previous approaches, this beacon has advantages of higher target to background ratio of detection and an increased resistance to nuclease degradation. The strategy reported in this study is a promising approach for the intracellular measurement of RNA or protein expression in living cells, and has great potential in the study of drug screening and discovery. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Impact of cognitive radio on radio astronomy

    NARCIS (Netherlands)

    Bentum, Marinus Jan; Boonstra, A.J.; Baan, W.A.

    2010-01-01

    The introduction of new communication techniques requires an increase in the efficiency of spectrum usage. Cognitive radio is one of the new techniques that fosters spectrum efficiency by using unoccupied frequency spectrum for communications. However, cognitive radio will increase the transmission

  5. Fast Radio Bursts

    Indian Academy of Sciences (India)

    Akshaya Rane

    2017-09-12

    ) which were first discovered a decade ago. Following an introduction to radio transients in general, including pulsars and rotating radio transients, we discuss the discovery of FRBs. We then discuss FRB follow-up ...

  6. Supplementary Material for: BEACON: automated tool for Bacterial GEnome Annotation ComparisON

    KAUST Repository

    Kalkatawi, Manal M.; Alam, Intikhab; Bajic, Vladimir B.

    2015-01-01

    Abstract Background Genome annotation is one way of summarizing the existing knowledge about genomic characteristics of an organism. There has been an increased interest during the last several decades in computer-based structural and functional genome annotation. Many methods for this purpose have been developed for eukaryotes and prokaryotes. Our study focuses on comparison of functional annotations of prokaryotic genomes. To the best of our knowledge there is no fully automated system for detailed comparison of functional genome annotations generated by different annotation methods (AMs). Results The presence of many AMs and development of new ones introduce needs to: a/ compare different annotations for a single genome, and b/ generate annotation by combining individual ones. To address these issues we developed an Automated Tool for Bacterial GEnome Annotation ComparisON (BEACON) that benefits both AM developers and annotation analysers. BEACON provides detailed comparison of gene function annotations of prokaryotic genomes obtained by different AMs and generates extended annotations through combination of individual ones. For the illustration of BEACONâ s utility, we provide a comparison analysis of multiple different annotations generated for four genomes and show on these examples that the extended annotation can increase the number of genes annotated by putative functions up to 27 %, while the number of genes without any function assignment is reduced. Conclusions We developed BEACON, a fast tool for an automated and a systematic comparison of different annotations of single genomes. The extended annotation assigns putative functions to many genes with unknown functions. BEACON is available under GNU General Public License version 3.0 and is accessible at: http://www.cbrc.kaust.edu.sa/BEACON/ .

  7. La radio digital

    Directory of Open Access Journals (Sweden)

    Carlos Eduardo Cortés S.

    2015-01-01

    Full Text Available La radio digital es un producto de la llamada convergencia digital. Las nuevas tecnologías interconectadas permiten la aparición de nuevos modos de audiencia y la implementación de herramientas versátiles. Habla del problema de los estándares, de la radio satelital, la radio digital terrestre, las radios internacionales, la interactividad.

  8. Commercial Radio as Communication.

    Science.gov (United States)

    Rothenbuhler, Eric W.

    1996-01-01

    Compares the day-to-day work routines of commercial radio with the principles of a theoretical communication model. Illuminates peculiarities of the conduct of communication by commercial radio. Discusses the application of theoretical models to the evaluation of practicing institutions. Offers assessments of commercial radio deriving from…

  9. Ham radio for dummies

    CERN Document Server

    Silver, H Ward

    2013-01-01

    An ideal first step for learning about ham radio Beyond operating wirelessly, today's ham radio operators can transmit data and pictures; use the Internet, laser, and microwave transmitters; and travel to places high and low to make contact. This hands-on beginner guide reflects the operational and technical changes to amateur radio over the past decade and provides you with updated licensing requirements and information, changes in digital communication (such as the Internet, social media, and GPS), and how to use e-mail via radio. Addresses the critical use of ham radio for replacing downe

  10. BEACON/MOD: a computer program for thermal-hydraulic analysis of nuclear reactor containments - user's manual

    International Nuclear Information System (INIS)

    Broadus, C.R.; Doyle, R.J.; James, S.W.; Lime, J.F.; Mings, W.J.

    1980-04-01

    The BEACON code is a best-estimate, advanced containment code designed to perform a best-estimate analysis of the flow of a mixture of air, water, and steam in a nuclear reactor containment system under loss-of-coolant accident conditions. The code can simulate two-component, two-phase fluid flow in complex geometries using a combination of two-dimensional, one-dimensional, and lumped-parameter representations for the various parts of the system. The current version of BEACON, which is designated BEACON/MOD3, contains mass and heat transfer models for wall film and wall conduction. It is suitable for the evaluation of short-term transients in dry-containment systems. This manual describes the models employed in BEACON/MOD3 and specifies code implementation requirements. It provides application information for input data preparation and for output data interpretation

  11. BEACON/MOD2A analysis of the Arkansas-1 reactor cavity during a hypothetical hot leg break

    International Nuclear Information System (INIS)

    Ramsthaler, J.A.

    1979-01-01

    As part of the evaluation of the new MOD2A version of the BEACON code, the Arkansas-1 reactor cavity was modeled during a hypothetical loss-of-coolant accident. Results of the BEACON analysis were compared with results obtained previously with the COMPARE containment code. Studies were also made investigating some of the BEACON interphasic, timestep control, and wall heat transfer options to assure that these models were working properly and to observe their effects on the results. Descriptions of the Arkansas-1 reactor cavity, initial assumptions during the hypothetical LOCA, and methods of modeling with BEACON are presented. Some of the problems encountered in accurately modeling the penetrations surrounding the hot and cold leg pipes are also discussed

  12. Radiography of Spanish Radio

    Directory of Open Access Journals (Sweden)

    Dra. Emma Rodero Antón

    2007-01-01

    Full Text Available In its eighty years of existence, radio has been always characterized to adapt to the social, cultural and technological transformations. Thus it has been until this moment. Nevertheless, some years ago, the authors and professionals of this medium have been detecting a stagnation that affects to its structure. At a time in continuous technological evolution, radio demands a deep transformation. For that reason, from the conviction of which the future radio, public and commercial, will necessarily have to renew itself, in this paper we establish ten problems and their possible solutions to the radio crisis in order to draw an x-ray of radio in Spain. Radio has future, but it is necessary to work actively by it. That the radio continues being part of sound of our life, it will depend on the work of all: companies, advertisers, professionals, students, investigators and listeners.

  13. Traveling-Wave Tube Amplifier Second Harmonic as Millimeter-Wave Beacon Source for Atmospheric Propagation Studies

    Science.gov (United States)

    Simons, Rainee N.; Wintucky, Edwin G.

    2014-01-01

    This paper presents the design and test results of a CW millimeter-wave satellite beacon source, based on the second harmonic from a traveling-wave tube amplifier and utilizes a novel waveguide multimode directional coupler. A potential application of the beacon source is for investigating the atmospheric effects on Q-band (37-42 GHz) and V/W-band (71- 76 GHz) satellite-to-ground signals.

  14. Cleavable DNA-protein hybrid molecular beacon: A novel efficient signal translator for sensitive fluorescence anisotropy bioassay.

    Science.gov (United States)

    Hu, Pan; Yang, Bin

    2016-01-15

    Due to its unique features such as high sensitivity, homogeneous format, and independence on fluorescent intensity, fluorescence anisotropy (FA) assay has become a hotspot of study in oligonucleotide-based bioassays. However, until now most FA probes require carefully customized structure designs, and thus are neither generalizable for different sensing systems nor effective to obtain sufficient signal response. To address this issue, a cleavable DNA-protein hybrid molecular beacon was successfully engineered for signal amplified FA bioassay, via combining the unique stable structure of molecular beacon and the large molecular mass of streptavidin. Compared with single DNA strand probe or conventional molecular beacon, the DNA-protein hybrid molecular beacon exhibited a much higher FA value, which was potential to obtain high signal-background ratio in sensing process. As proof-of-principle, this novel DNA-protein hybrid molecular beacon was further applied for FA bioassay using DNAzyme-Pb(2+) as a model sensing system. This FA assay approach could selectively detect as low as 0.5nM Pb(2+) in buffer solution, and also be successful for real samples analysis with good recovery values. Compatible with most of oligonucleotide probes' designs and enzyme-based signal amplification strategies, the molecular beacon can serve as a novel signal translator to expand the application prospect of FA technology in various bioassays. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Site-specific standard request for Underground Storage Tanks 1219-U, 1222-U, 2082-U, and 2068-U at the Rust Garage Facility Buildings 9754-1 and 9720-15

    International Nuclear Information System (INIS)

    1994-08-01

    This document is a site-specific standard request for underground storage tanks located at the Rust Garage Facility. These standards are justified based on conclusion derived from the exposure assessment that indicates there is no current or forseeable future human health risk associated with petroleum contaminants on the site, that current and future ecological risks would be generally limited to subsurface species and plant life with roots extending into the area, and that most of the impacted area at the site is covered by asphalt or concrete. The vertical and horizontal extent of soil and ground water contamination are limited to immediate area of the Rust Garage Facility

  16. Visually Detecting the Variation of miR-301a Expression Using Gold Nanoparticle Beacon.

    Science.gov (United States)

    Zhang, Ying; Li, Kai; Li, Dandan; Li, Changfeng; Zhang, Bin

    2018-02-01

    It is well known that microRNA-301a plays an important role in many diseases, as well as is overexpressed in human colon cancer and affects the process of tumorigenesis. Determination of the miR-301a expression provides insight into the mechanism of tumor progression. In this study, we designed a special hairpin deoxyribonucleic acid (DNA) for miR-301a to functionalize gold nanoparticles, which served as a beacon for detecting miR-301a expression. A-quenching efficiency up to 90% was achieved. The beacon we designed in this study can monitor the precise variation of miR-301a expression in vivo. The strategy reported in this study is a promising approach for the measurement of miRNA in living cells. Moreover, it has a great potential in the study of drug screening and discovery.

  17. Topical MMP beacon enabled fluorescence-guided resection of oral carcinoma

    Science.gov (United States)

    Burgess, Laura; Chen, Juan; Wolter, Nikolaus E.; Wilson, Brian; Zheng, Gang

    2016-01-01

    Each year almost 300,000 individuals worldwide are diagnosed with oral cancer, more than 90% of these being oral carcinoma [N. Engl. J. Med. 328, 184 19938417385]. Surgical resection is the standard of care, but accurate delineation of the tumor boundaries is challenging, resulting in either under-resection with risk of local recurrence or over-resection with increased functional loss and negative impact on quality of life. This study evaluates, in two pre-clinical in vivo tumor models, the potential of fluorescence-guided resection using molecular beacons activated by metalloproteinases, which are frequently upregulated in human oral cancer. In both models there was rapid (beacon activation upon local application, allowing clear fluoresecence imaging in vivo and confirmed by ex vivo fluorescence microscopy and HPLC, with minimal activation in normal oral tissues. Although the tissue penetration was limited using topical application, these findings support further development of this approach towards translation to first-in-human trials. PMID:27231609

  18. Design of a K/Q-Band Beacon Receiver for the Alphasat TDP#5 Experiment

    Science.gov (United States)

    Morse, Jacquelynne R.

    2014-01-01

    This paper describes the design and performance of a coherent KQ-band (2040 GHz) beacon receiver developed at NASA Glenn Research Center (GRC) that will be installed at the Politecnico di Milano (POLIMI) for use in the Alphasat Technology Demonstration Payload 5 (TDP5) beacon experiment. The goal of this experiment is to characterize rain fade attenuation at 40 GHz to improve the performance of existing statistical rain attenuation models in the Q-band. The ground terminal developed by NASA GRC utilizes an FFT-based frequency estimation receiver capable of characterizing total path attenuation effects due to gaseous absorption, clouds, rain, and scintillation. The receiver system has been characterized in the lab and demonstrates a system dynamic range performance of better than 58 dB at 1 Hz and better than 48 dB at 10 Hz rates.

  19. Senior radio listeners

    DEFF Research Database (Denmark)

    Blaakilde, Anne Leonora

    Radiobroadcasting and the hardware materialization of radio have during the 20th century changed significantly, which means that senior radio listeners have travelled along with this evolution from large, impressive radio furnitures to DAB and small, wireless, mobile devices, and from grave...... and solemn radio voices to lightharted, laughing and chatting speakers. Senior radio listerners have experienced the development and refinements of technique, content and genres. It is now expected of all media users that they are capable of crossing media, combining, juggling and jumping between various...... media platforms, not the least when listening to radio. The elder generation is no exception from this. Recently, for instance, the Danish public broadcast DR has carried out an exodus of programmes targeted for the senior segment. These programmes are removed from regular FM and sent to DAB receivers...

  20. Increased dose near the skin due to electromagnetic surface beacon transponder.

    Science.gov (United States)

    Ahn, Kang-Hyun; Manger, Ryan; Halpern, Howard J; Aydogan, Bulent

    2015-05-08

    The purpose of this study was to evaluate the increased dose near the skin from an electromagnetic surface beacon transponder, which is used for localization and tracking organ motion. The bolus effect due to the copper coil surface beacon was evaluated with radiographic film measurements and Monte Carlo simulations. Various beam incidence angles were evaluated for both 6 MV and 18 MV experimentally. We performed simulations using a general-purpose Monte Carlo code MCNPX (Monte Carlo N-Particle) to supplement the experimental data. We modeled the surface beacon geometry using the actual mass of the glass vial and copper coil placed in its L-shaped polyethylene terephthalate tubing casing. Film dosimetry measured factors of 2.2 and 3.0 enhancement in the surface dose for normally incident 6 MV and 18 MV beams, respectively. Although surface dose further increased with incidence angle, the relative contribution from the bolus effect was reduced at the oblique incidence. The enhancement factors were 1.5 and 1.8 for 6 MV and 18 MV, respectively, at an incidence angle of 60°. Monte Carlo simulation confirmed the experimental results and indicated that the epidermal skin dose can reach approximately 50% of the dose at dmax at normal incidence. The overall effect could be acceptable considering the skin dose enhancement is confined to a small area (~ 1 cm2), and can be further reduced by using an opposite beam technique. Further clinical studies are justified in order to study the dosimetric benefit versus possible cosmetic effects of the surface beacon. One such clinical situation would be intact breast radiation therapy, especially large-breasted women.

  1. Surface-attached molecular beacons light the way for DNA sequencing

    Czech Academy of Sciences Publication Activity Database

    Paleček, Emil

    2004-01-01

    Roč. 22, č. 2 (2004), s. 55-58 ISSN 0167-7799 R&D Projects: GA AV ČR IBS5004355; GA ČR GA204/03/0566 Institutional research plan: CEZ:AV0Z5004920 Keywords : molecular beacon * DNA stem-loop structure * DNA sensors Subject RIV: BO - Biophysics Impact factor: 8.606, year: 2004

  2. Beacon: A three-dimensional structural analysis code for bowing history of fast breeder reactor cores

    International Nuclear Information System (INIS)

    Miki, K.

    1979-01-01

    The core elements of an LMFBR are bowed due to radial gradients of both temperature and neutron flux in the core. Since all hexagonal elements are multiply supported by adjacent elements or the restraint system, restraint forces and bending stresses are induced. In turn, these forces and stresses are relaxed by irradiation enhanced creep of the material. The analysis of the core bowing behavior requires a three-dimensional consideration of the mechanical interactions among the core elements, because the core consists of different kinds of elements and of fuel assemblies with various burnup histories. A new computational code BEACON has been developed for analyzing the bowing behavior of an LMFBR's core in three dimensions. To evaluate mechanical interactions among core elements, the code uses the analytical method of the earlier SHADOW code. BEACON analyzes the mechanical interactions in three directions, which form angles of 60 0 with one another. BEACON is applied to the 60 0 sector of a typical LMFBR's core for analyzing the bowing history during one equilibrium cycle. 120 core elements are treated, assuming the boundary condition of rotational symmetry. The application confirms that the code can be an effective tool for parametric studies as well as for detailed structural analysis of LMFBR's core. (orig.)

  3. Magnetic resonance beacon to detect intracellular microRNA during neurogenesis.

    Science.gov (United States)

    Lee, Jonghwan; Jin, Yeon A; Ko, Hae Young; Lee, Yong Seung; Heo, Hyejung; Cho, Sujeong; Kim, Soonhag

    2015-02-01

    Magnetic resonance imaging (MRI) offers great spatial resolution for viewing deep tissues and anatomy. We developed a self-assembling signal-on magnetic fluorescence nanoparticle to visualize intracellular microRNAs (miRNAs or miRs) during neurogenesis using MRI. The self-assembling nanoparticle (miR124a MR beacon) was aggregated by the incubation of three different oligonucleotides: a 3' adaptor, a 5' adaptor, and a linker containing miR124a-binding sequences. The T2-weighted magnetic resonance (MR) signal of the self-assembled nanoparticle was quenched when miR124a was absent from test tubes or was minimally expressed in cells and tissues. When miR124a was present in test tubes or highly expressed in vitro and in vivo during P19 cell neurogenesis, it hybridized with the miR124a MR beacon, causing the linker to detach, resulting in increased signal-on MRI intensity. This MR beacon can be used as a new imaging probe to monitor the miRNA-mediated regulation of cellular processes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. A Microfluidic Love-Wave Biosensing Device for PSA Detection Based on an Aptamer Beacon Probe.

    Science.gov (United States)

    Zhang, Feng; Li, Shuangming; Cao, Kang; Wang, Pengjuan; Su, Yan; Zhu, Xinhua; Wan, Ying

    2015-06-11

    A label-free and selective aptamer beacon-based Love-wave biosensing device was developed for prostate specific antigen (PSA) detection. The device consists of the following parts: LiTaO3 substrate with SiO2 film as wave guide layer, two set of inter-digital transducers (IDT), gold film for immobilization of the biorecongniton layer and a polydimethylsiloxane (PDMS) microfluidic channels. DNA aptamer, or "artificial antibody", was used as the specific biorecognition probe for PSA capture. Some nucleotides were added to the 3'-end of the aptamer to form a duplex with the 3'-end, turning the aptamer into an aptamer-beacon. Taking advantage of the selective target-induced assembly changes arising from the "aptamer beacon", highly selective and specific detection of PSA was achieved. Furthermore, PDMS microfluidic channels were designed and fabricated to realize automated quantitative sample injection. After optimization of the experimental conditions, the established device showed good performance for PSA detection between 10 ng/mL to 1 μg/mL, with a detection limit of 10 ng/mL. The proposed sensor might be a promising alternative for point of care diagnostics.

  5. Sparse Localization with a Mobile Beacon Based on LU Decomposition in Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Chunhui Zhao

    2015-09-01

    Full Text Available Node localization is the core in wireless sensor network. It can be solved by powerful beacons, which are equipped with global positioning system devices to know their location information. In this article, we present a novel sparse localization approach with a mobile beacon based on LU decomposition. Our scheme firstly translates node localization problem into a 1-sparse vector recovery problem by establishing sparse localization model. Then, LU decomposition pre-processing is adopted to solve the problem that measurement matrix does not meet the re¬stricted isometry property. Later, the 1-sparse vector can be exactly recovered by compressive sensing. Finally, as the 1-sparse vector is approximate sparse, weighted Cen¬troid scheme is introduced to accurately locate the node. Simulation and analysis show that our scheme has better localization performance and lower requirement for the mobile beacon than MAP+GC, MAP-M, and MAP-MN schemes. In addition, the obstacles and DOI have little effect on the novel scheme, and it has great localization performance under low SNR, thus, the scheme proposed is robust.

  6. Gurus in the garage.

    Science.gov (United States)

    Leonard, D; Swap, W

    2000-01-01

    Before the days of the Internet, it was primarily venture capitalists who coached young entrepreneurs in Silicon Valley. Today, because of the phenomenal number of new companies, venture capitalists are just too busy. The largest firms still take on a few carefully selected, highly promising zero-stage start-ups, but they simply can't spend the time on ones that aren't going to grow huge quickly. To fill the void, a new breed of adviser has stepped in to coach entrepreneurs. Called mentor capitalists, they help entrepreneurs with everything from recruiting top talent to attracting their first million in seed money. The mentor capitalists in Silicon Valley are cashed-out, highly successful business architects who no longer want to start businesses but who love the thrill of the entrepreneurial game. They spend hours and hours with first-time entrepreneurs, guiding them as they create and refine a business model, test their ideas in the marketplace, build business processes, raise money, and find talent. The authors of this article found through dozens of extensive interviews with entrepreneurs and their coaches that mentor capitalists play many roles: sculptor, psychologist, diplomat, kingmaker, talent magnet, process engineer, and rainmaker. In exchange for small equity stakes, the mentor capitalists wear these different hats, doling out expertise just in time, as situations arise, and in doses appropriate to the situation. Mentor capitalists seed Silicon Valley with expertise and knowledge, augmenting or even substituting for classes in entrepreneurship at local universities. But, as the authors note, the role of the mentor capitalist is essential to any start-up, anywhere.

  7. Ionosphere and Radio Communication

    Indian Academy of Sciences (India)

    The upperionosphere is used for radio communication and navigationas it reflects long, medium, as well as short radio waves. Sincesolar radiation is the main cause of the existence of ionosphere,any variation in the radiations can affect the entireradio communication system. This article attempts to brieflyintroduce the ...

  8. Writing for Radio.

    Science.gov (United States)

    Tupper, Marianna S.

    1995-01-01

    Describes a 24-hour commercial radio station simulation class project for eighth-grade language arts. Students wrote their own scripts, chose music and were disc jockeys on their own music and talk shows, and prepared news and traffic reports. Guest speakers from actual commercial radio came in to discuss issues such as advertising, censorship,…

  9. Valuing commercial radio licences

    NARCIS (Netherlands)

    Kerste, M.; Poort, J.; van Eijk, N.

    2015-01-01

    Within the EU regulatory framework, licensees for commercial radio broadcasting may be charged a fee to ensure optimal allocation of scarce resources but not to maximize public revenues. While radio licence renewal occurs in many EU countries, an objective, model-based approach for setting licence

  10. The Radio Jove Project

    Science.gov (United States)

    Thieman, J. R.

    2010-01-01

    The Radio love Project is a hands-on education and outreach project in which students, or any other interested individuals or groups build a radio telescope from a kit, operate the radio telescope, transmit the resulting signals through the internet if desired, analyze the results, and share the results with others through archives or general discussions among the observers. Radio love is intended to provide an introduction to radio astronomy for the observer. The equipment allows the user to observe radio signals from Jupiter, the Sun, the galaxy, and Earth-based radiation both natural and man-made. The project was started through a NASA Director's Discretionary Fund grant more than ten years ago. it has continued to be carried out through the dedicated efforts of a group of mainly volunteers. Dearly 1500 kits have been distributed throughout the world. Participation can also be done without building a kit. Pre-built kits are available. Users can also monitor remote radio telescopes through the internet using free downloadable software available through the radiosky.com website. There have been many stories of prize-winning projects, inspirational results, collaborative efforts, etc. We continue to build the community of observers and are always open to new thoughts about how to inspire the observers to still greater involvement in the science and technology associated with Radio Jove.

  11. Boom Booom Net Radio

    DEFF Research Database (Denmark)

    Grimshaw, Mark Nicholas; Yong, Louisa; Dobie, Ian

    1999-01-01

    of an existing Internet radio station; Boom Booom Net Radio. Whilst necessity dictates some use of technology-related terminology, wherever possible we have endeavoured to keep such jargon to a minimum and to either explain it in the text or to provide further explanation in the appended glossary....

  12. Microminiature radio frequency transmitter for communication and tracking applications

    Science.gov (United States)

    Crutcher, Richard I.; Emery, Mike S.; Falter, Kelly G.; Nowlin, C. H.; Rochelle, Jim M.; Clonts, Lloyd G.

    1997-02-01

    A micro-miniature radio frequency (rf) transmitter has been developed and demonstrated by the Oak Ridge National Laboratory. The objective of the rf transmitter development was to maximize the transmission distance while drastically shrinking the overall transmitter size, including antenna. Based on analysis and testing, an application-specific integrated circuit (ASIC) with a 16-GHz gallium arsenide (GaAs) oscillator and integrated on-chip antenna was designed and fabricated using microwave monolithic integrated circuit (MMIC) technology. Details of the development and the results of various field tests are discussed. The rf transmitter is applicable to covert surveillance and tracking scenarios due to its small size of 2.2 multiplied by 2.2 mm, including the antenna. Additionally, the 16-GHz frequency is well above the operational range of consumer-grade radio scanners, providing a degree of protection from unauthorized interception. Variations of the transmitter design have been demonstrated for tracking and tagging beacons, transmission of digital data, and transmission of real-time analog video from a surveillance camera. Preliminary laboratory measurements indicate adaptability to direct-sequence spread-spectrum transmission, providing a low probability of intercept and/or detection. Concepts related to law enforcement applications are presented.

  13. Portable Integrated Wireless Device Threat Assessment to Aircraft Radio Systems

    Science.gov (United States)

    Salud, Maria Theresa P.; Williams, Reuben A. (Technical Monitor)

    2004-01-01

    An assessment was conducted on multiple wireless local area network (WLAN) devices using the three wireless standards for spurious radiated emissions to determine their threat to aircraft radio navigation systems. The measurement process, data and analysis are provided for devices tested using IEEE 802.11a, IEEE 802.11b, and Bluetooth as well as data from portable laptops/tablet PCs and PDAs (grouping known as PEDs). A comparison was made between wireless LAN devices and portable electronic devices. Spurious radiated emissions were investigated in the radio frequency bands for the following aircraft systems: Instrument Landing System Localizer and Glideslope, Very High Frequency (VHF) Communication, VHF Omnidirectional Range, Traffic Collision Avoidance System, Air Traffic Control Radar Beacon System, Microwave Landing System and Global Positioning System. Since several of the contiguous navigation systems were grouped under one encompassing measurement frequency band, there were five measurement frequency bands where spurious radiated emissions data were collected for the PEDs and WLAN devices. The report also provides a comparison between emissions data and regulatory emission limit.

  14. Surveillance technology for HIV-1 subtype C in Ethiopia: an env-based NASBA molecular beacon assay to discriminate between subcluster C and C'

    NARCIS (Netherlands)

    Ayele, Workenesh; Baar, Michel P. de; Goudsmit, Jaap; Kliphuis, Aletta; Tilahun, Tesfaye; Dorigo-Zetsma, Wendelien; Wolday, Dawit; Abebe, Almaz; Mengistu, Yohannes; Pollakis, Georgios

    2005-01-01

    Forty-nine samples with known C2V3 sequences were used for the evaluation of an env-based molecular beacon assay to distinguish between the two genetic subclusters C and C' which characterize the HIV-1 epidemic in Ethiopia. Two subcluster C and two subcluster C' beacons targeting two different loci

  15. Unlocking radio broadcasts

    DEFF Research Database (Denmark)

    Skov, Mette; Lykke, Marianne

    2012-01-01

    This poster reports the preliminary results of a user study uncovering the information seeking behaviour of humanities scholars dedicated to radio research. The study is part of an interdisciplinary research project on radio culture and auditory resources. The purpose of the study is to inform...... the design of information architecture and interaction design of a research infrastructure that will enable future radio and audio based research. Results from a questionnaire survey on humanities scholars‟ research interest and information needs, preferred access points, and indexing levels are reported....... Finally, a flexible metadata schema is suggested, that includes both general metadata and highly media and research project specific metadata....

  16. Radio y elecciones

    Directory of Open Access Journals (Sweden)

    Alma Rosa Alva de la Selva

    2000-01-01

    Full Text Available En este trabajo se analiza el comportamiento de la radio en México ante la contienda electoral de julio de 2000. Se examina el papel de la radio como espacio para la discusión política, así como el tratamiento informativo que hizo del tema. Asimismo, se analiza la posible repercusión de factores de reciente surgimiento en el panorama radiofónico para un manejo más autónomo de la información política en la radio

  17. Remaining Sites Verification Package for the 100-B-20, 1716-B Maintenance Garage Underground Tank, Waste Site Reclassification Form 2006-019

    Energy Technology Data Exchange (ETDEWEB)

    L. M. Dittmer

    2006-09-27

    The 100-B-20 waste site, located in the 100-BC-1 Operable Unit of the Hanford Site, consisted of an underground oil tank that once serviced the 1716-B Maintenance Garage. The selected action for the 100-B-20 waste site involved removal of the oil tanks and their contents and demonstrating through confirmatory sampling that all cleanup goals have been met. In accordance with this evaluation, a reclassification status of interim closed out has been determined. The results demonstrate that the site will support future unrestricted land uses that can be represented by a rural-residential scenario. These results also show that residual concentrations support unrestricted future use of shallow zone soil and that contaminant levels remaining in the soil are protective of groundwater and the Columbia River.

  18. The horizontal gender segregation and its consequences in the masculinised occupation of mechanic (M/F in the subsector of motor vehicle repair garages in Spain

    Directory of Open Access Journals (Sweden)

    María del Mar Maira Vidal

    2017-07-01

    Full Text Available This paper is based on the results of two research projects of the research group “Women in men’s worlds”: the research project “Women in men’s worlds: Barriers to enter and strategies to overcome them” (Ref.: FEM2011-25228, financed by the National Plan of the Ministry of Economy and Competitiveness between January 2011 and December 2013; and the project “Women in men’s worlds: Socialisation, labour organisation, and image” (CSO2014-54339-P, also financed by the National Plan between September 2015 and September 2018. In both research projects we have analysed occupational horizontal gender segregation in masculinised occupations in Spain. In this paper we present the results of both research projects about female garage mechanics, whose training and occupation reveal a very high rate of gender-related segregation or cases of gender-related discrimination and harassment or sexual harassment.

  19. Remaining Sites Verification Package for the 100-B-20, 1716-B Maintenance Garage Underground Tank. Attachment to Waste Site Reclassification Form 2006-019

    International Nuclear Information System (INIS)

    Dittmer, L.M.

    2006-01-01

    The 100-B-20 waste site, located in the 100-BC-1 Operable Unit of the Hanford Site, consisted of an underground oil tank that once serviced the 1716-B Maintenance Garage. The selected action for the 100-B-20 waste site involved removal of the oil tanks and their contents and demonstrating through confirmatory sampling that all cleanup goals have been met. In accordance with this evaluation, a reclassification status of interim closed out has been determined. The results demonstrate that the site will support future unrestricted land uses that can be represented by a rural-residential scenario. These results also show that residual concentrations support unrestricted future use of shallow zone soil and that contaminant levels remaining in the soil are protective of groundwater and the Columbia River

  20. Molecular beacon probes-base multiplex NASBA Real-time for detection of HIV-1 and HCV.

    Science.gov (United States)

    Mohammadi-Yeganeh, S; Paryan, M; Mirab Samiee, S; Kia, V; Rezvan, H

    2012-06-01

    Developed in 1991, nucleic acid sequence-based amplification (NASBA) has been introduced as a rapid molecular diagnostic technique, where it has been shown to give quicker results than PCR, and it can also be more sensitive. This paper describes the development of a molecular beacon-based multiplex NASBA assay for simultaneous detection of HIV-1 and HCV in plasma samples. A well-conserved region in the HIV-1 pol gene and 5'-NCR of HCV genome were used for primers and molecular beacon design. The performance features of HCV/HIV-1 multiplex NASBA assay including analytical sensitivity and specificity, clinical sensitivity and clinical specificity were evaluated. The analysis of scalar concentrations of the samples indicated that the limit of quantification of the assay was beacon probes detected all HCV genotypes and all major variants of HIV-1. This method may represent a relatively inexpensive isothermal method for detection of HIV-1/HCV co-infection in monitoring of patients.

  1. Creating a Connected Community: Lessons Learned from the Western New York Beacon Community

    Science.gov (United States)

    Maloney, Nancy; Heider, Arvela R.; Rockwood, Amy; Singh, Ranjit

    2014-01-01

    Introduction: Secure exchange of clinical data among providers has the potential to improve quality, safety, efficiency, and reduce duplication. Many communities are experiencing challenges in building effective health information exchanges (HIEs). Previous studies have focused on financial and technical issues regarding HIE development. This paper describes the Western New York (WNY) HIE growth and lessons learned about accelerating progress to become a highly connected community. Methods: HEALTHeLINK, with funding from the Office of the National Coordinator for Health Information Technology (ONC) under the Beacon Community Program, expanded HIE usage in eight counties. The communitywide transformation process used three main drivers: (1) a communitywide Electronic Health Record (EHR) adoption program; (2) clinical transformation partners; and (3) HIE outreach and infrastructure development. Results: ONC Beacon Community funding allowed WNY to achieve a new level in the use of interoperable HIE. Electronic delivery of results into the EHR expanded from 23 practices in 2010 to 222 practices in 2013, a tenfold increase. There were more than 12.5 million results delivered electronically (HL7 messages) to 222 practices’ EHRs via the HIE in 2013. Use of a secure portal and Virtual Health Record (VHR) to access reports (those not delivered directly to the EHR) also increased significantly, from 13,344 report views in 2010 to over 600,000 in 2013. Discussion and Conclusion: The WNY Beacon successfully expanded the sharing of clinical information among different sources of data and providers, creating a highly connected community to improve the quality and continuity of care. Technical, organizational, and community lessons described in this paper should prove beneficial to others as they pursue efforts to create connected communities. PMID:25848618

  2. Making it local: Beacon Communities use health information technology to optimize care management.

    Science.gov (United States)

    Allen, Amy; Des Jardins, Terrisca R; Heider, Arvela; Kanger, Chatrian R; Lobach, David F; McWilliams, Lee; Polello, Jennifer M; Rein, Alison L; Schachter, Abigail A; Singh, Ranjit; Sorondo, Barbara; Tulikangas, Megan C; Turske, Scott A

    2014-06-01

    Care management aims to provide cost-effective, coordinated, non-duplicative care to improve care quality, population health, and reduce costs. The 17 communities receiving funding from the Office of the National Coordinator for Health Information Technology through the Beacon Community Cooperative Agreement Program are leaders in building and strengthening their health information technology (health IT) infrastructure to provide more effective and efficient care management. This article profiles 6 Beacon Communities' health IT-enabled care management programs, highlighting the influence of local context on program strategy and design, and describing challenges, lessons learned, and policy implications for care delivery and payment reform. The unique needs (eg, disease burden, demographics), community partnerships, and existing resources and infrastructure all exerted significant influence on the overall priorities and design of each community's care management program. Though each Beacon Community needed to engage in a similar set of care management tasks--including patient identification, stratification, and prioritization; intervention; patient engagement; and evaluation--the contextual factors helped shape the specific strategies and tools used to carry out these tasks and achieve their objectives. Although providers across the country are striving to deliver standardized, high-quality care, the diverse contexts in which this care is delivered significantly influence the priorities, strategies, and design of community-based care management interventions. Gaps and challenges in implementing effective community-based care management programs include: optimizing allocation of care management services; lack of available technology tailored to care management needs; lack of standards and interoperability; integrating care management into care settings; evaluating impact; and funding and sustainability.

  3. A distance-dependent metal-enhanced fluorescence sensing platform based on molecular beacon design.

    Science.gov (United States)

    Zhou, Zhenpeng; Huang, Hongduan; Chen, Yang; Liu, Feng; Huang, Cheng Zhi; Li, Na

    2014-02-15

    A new metal-enhanced fluorescence (MEF) based platform was developed on the basis of distance-dependent fluorescence quenching-enhancement effect, which combined the easiness of Ag-thiol chemistry with the MEF property of noble-metal structures as well as the molecular beacon design. For the given sized AgNPs, the fluorescence enhancement factor was found to increase with a d(6) dependency in agreement with fluorescence resonance energy transfer mechanism at shorter distance and decrease with a d(-3) dependency in agreement with plasmonic enhancement mechanism at longer distance between the fluorophore and the AgNP surface. As a proof of concept, the platform was demonstrated by a sensitive detection of mercuric ions, using thymine-containing molecular beacon to tune silver nanoparticle (AgNP)-enhanced fluorescence. Mercuric ions were detected via formation of a thymine-mercuric-thymine structure to open the hairpin, facilitating fluorescence recovery and AgNP enhancement to yield a limit of detection of 1 nM, which is well below the U.S. Environmental Protection Agency regulation of the Maximum Contaminant Level Goal (10nM) in drinking water. Since the AgNP functioned as not only a quencher to reduce the reagent blank signal but also an enhancement substrate to increase fluorescence of the open hairpin when target mercuric ions were present, the quenching-enhancement strategy can greatly improve the detection sensitivity and can in principle be a universal approach for various targets when combined with molecular beacon design. © 2013 Elsevier B.V. All rights reserved.

  4. Performance of the NASA Beacon Receiver for the Alphasat Aldo Paraboni TDP5 Propagation Experiment

    Science.gov (United States)

    Nessel, James; Morse, Jacquelynne; Zemba, Michael; Riva, Carlo; Luini, Lorenzo

    2015-01-01

    NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 gigahertz band. NASA GRC has developed and installed a K/Q-band (20/40 gigahertz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20/40 gigahertz signals broadcast from the Alphasat Aldo Paraboni Technology Demonstration Payload (TDP) no. 5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we describe the design and preliminary performance of the NASA propagation terminal, which has been installed and operating in Milan since June 2014. The receiver is based upon a validated Fast Fourier Transform (FFT) I/Q digital design approach utilized in other operational NASA propagation terminals, but has been modified to employ power measurement via a frequency estimation technique and to coherently track and measure the amplitude of the 20/40 gigahertz beacon signals. The system consists of a 1.2-meter K-band and a 0.6-meter Q-band Cassegrain reflector employing synchronous open-loop tracking to track the inclined orbit of the Alphasat satellite. An 8 hertz sampling rate is implemented to characterize scintillation effects, with a 1-hertz measurement bandwidth dynamic range of 45 decibels. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models.

  5. Preliminary Results of the NASA Beacon Receiver for Alphasat Aldo Paraboni TDP5 Propagation Experiment

    Science.gov (United States)

    Nessel, James; Morse, Jacquelynne; Zemba, Michael; Riva, Carlo; Luini, Lorenzo

    2014-01-01

    NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 GHz band. NASA GRC has developed and installed a K/Q-band (20/40 GHz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20/40 GHz signals broadcast from the Alphasat Aldo Paraboni TDP#5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we describe the design and preliminary performance of the NASA propagation terminal, which has been installed and operating in Milan since May 2014. The receiver is based upon a validated Fast Fourier Transform (FFT) I/Q digital design approach utilized in other operational NASA propagation terminals, but has been modified to employ power measurement via a frequency estimation technique and to coherently track and measure the amplitude of the 20/40 GHz beacon signals. The system consists of a 1.2-m K-band and a 0.6-m Qband Cassegrain reflector employing synchronous open-loop tracking to track the inclined orbit of the Alphasat satellite. An 8 Hz sampling rate is implemented to characterize scintillation effects, with a 1-Hz measurement bandwidth dynamic range of 45 dB. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models.

  6. Social cognitive radio networks

    CERN Document Server

    Chen, Xu

    2015-01-01

    This brief presents research results on social cognitive radio networks, a transformational and innovative networking paradigm that promotes the nexus between social interactions and cognitive radio networks. Along with a review of the research literature, the text examines the key motivation and challenges of social cognitive radio network design. Three socially inspired distributed spectrum sharing mechanisms are introduced: adaptive channel recommendation mechanism, imitation-based social spectrum sharing mechanism, and evolutionarily stable spectrum access mechanism. The brief concludes with a discussion of future research directions which ascertains that exploiting social interactions for distributed spectrum sharing will advance the state-of-the-art of cognitive radio network design, spur a new line of thinking for future wireless networks, and enable novel wireless service and applications.

  7. NOAA Weather Radio

    Science.gov (United States)

    del tiempo incluido. Si eres quieres ser avisado de las advertencias y relojes de día o de noche, un Weather Radio relojes son independientes o basadas en el Condado (parroquia basados en Luisiana), aunque

  8. The digital sport radio.

    Directory of Open Access Journals (Sweden)

    Hilario José ROMERO BEJARANO

    2014-07-01

    Full Text Available Radio has been immersed in recent years in a phase of technological integration and business of multimedia, as well as diversification of systems and channels for broadcasting. In addition, Internet has been consolidated as the platform of digital radio that more has evolved as a result of its continued expansion. However, the merger radio-Internet must be understood as a new form of communication, and not solely as a new complementary medium. In this context, it is of great interest to analyze that transformations in the way of reception, contents, languages, programs and schedules, has brought with it for the radio that integration. To this end is taken as main reference the sports areas, a key aspect and broadly representative of the current broadcasting landscape.

  9. Music, radio and mediatization

    DEFF Research Database (Denmark)

    Michelsen, Morten; Krogh, Mads

    2016-01-01

    of mediatization where media as such seem to be ascribed agency. Instead, we consider historical accounts of music–radio in order to address the complex nonlinearity of concrete processes of mediatization as they take place in the multiple meetings between a decentred notion of radio and musical life.......Mediatization has become a key concept for understanding the relations between media and other cultural and social fields. Contributing to the discussions related to the concept of mediatization, this article discusses how practices of radio and music(al life) influence each other. We follow Deacon......’s and Stanyer’s advice to supplement the concept of mediatization with ‘a series of additional concepts at lower levels of abstraction’ and suggest, in this respect, the notion of heterogeneous milieus of music–radio. Hereby, we turn away from the all-encompassing perspectives related to the concept...

  10. ITSY Handheld Software Radio

    National Research Council Canada - National Science Library

    Bose, Vanu

    2001-01-01

    .... A handheld software radio platform would enable the construction of devices that could inter-operate with multiple legacy systems, download new waveforms and be used to construct adhoc networks...

  11. Structure in radio galaxies

    International Nuclear Information System (INIS)

    Breugel, W. van.

    1980-01-01

    It is shown that radio jets are a rather common phenomenon in radio galaxies. Jets can be disguised as trails in head-tail sources, bridges in double sources or simply remain undetected because of lack of resolution and sensitivity. It is natural to associate these jets with the channels which had previously been suggested to supply energy to the extended radio lobes. The observations of optical emission suggest that a continuous non-thermal spectrum extending from 10 9 to 10 15 Hz is a common property of jets. Because significant amounts of interstellar matter are also observed in each of the galaxies surveyed it seems that models for jets which involve an interaction with this medium may be most appropriate. New information about the overall structure of extended radio sources has been obtained from the detailed multifrequency study with the WSRT. (Auth.)

  12. The use of low frequency HF beacons to derive layer shape

    International Nuclear Information System (INIS)

    Heron, M.L.; Davies, K.

    1978-01-01

    The ATS-6 with its coherent multifrequency channels and various calibrations has brought the technology of beacon experiments to the point where the experimental accuracy exceeds that of some of the approximations used to derive total electron content. For example, the magnetic field term in the Faraday rotation experiment used to be given a mean value corresponding to about 50 km above the F layer peak. Another quantity that depends on profile shape is also available with present experiment, namely the refraction or second order term for carrier phase, modulation phase, or Faraday rotation. Some theoretical and experimental results are presented on these problems

  13. Developing children’s palliative care in Africa through beacon centres: lessons learnt

    Science.gov (United States)

    2013-01-01

    Much progress has been made in the provision of palliative care across sub-Saharan Africa, however much still remains to be done, particularly in the area of children’s palliative care (CPC). The Beacon Centres programme was set up in 2009, aimed at improving access to CPC in South Africa, Uganda and Tanzania through more and better-trained health professionals and CPC clinical services of a high standard. Having identified sites in each country to develop into CPC Beacon Centres, Navigators were identified who would be the ‘champions’ for CPC in those sites and lead a programme of training, mentorship and support. Five navigators (2 in Uganda and Tanzania and 1 in South Africa) were trained between September and December 2009. Following this they undertook CPC needs assessments at the 3 centres and set up and delivered a six-month CPC training programme, providing mentorship and support to students to enable them to integrate CPC into their workplaces. To date, 188 participants have commenced the six-month course, with 80 having completed it. CPC has been integrated into the activities of the centres and a CPC virtual resource centre set up in South Africa. The achievements from the Beacon project have been great and the work of the navigators immense, but as in all projects it has not been without its challenges. Lessons learnt include issues around: the focus of the project; the length and nature of the training; assessment; accreditation; the choice of navigators; mentoring; administrative support; co-ordination; the choice of project sites; and the integration of CPC into services. The need for CPC is not going to go away and it is therefore important that models of scaling-up are found that are not only practical, feasible, affordable and sustainable, but that focus on the outcome of improved CPC for all those who need it. It is hoped that the lessons shared from the Beacon Project will help in developing and implementing such models. PMID:23419095

  14. Controlling the signal: Practical privacy protection of genomic data sharing through Beacon services.

    Science.gov (United States)

    Wan, Zhiyu; Vorobeychik, Yevgeniy; Kantarcioglu, Murat; Malin, Bradley

    2017-07-26

    Genomic data is increasingly collected by a wide array of organizations. As such, there is a growing demand to make summary information about such collections available more widely. However, over the past decade, a series of investigations have shown that attacks, rooted in statistical inference methods, can be applied to discern the presence of a known individual's DNA sequence in the pool of subjects. Recently, it was shown that the Beacon Project of the Global Alliance for Genomics and Health, a web service for querying about the presence (or absence) of a specific allele, was vulnerable. The Integrating Data for Analysis, Anonymization, and Sharing (iDASH) Center modeled a track in their third Privacy Protection Challenge on how to mitigate the Beacon vulnerability. We developed the winning solution for this track. This paper describes our computational method to optimize the tradeoff between the utility and the privacy of the Beacon service. We generalize the genomic data sharing problem beyond that which was introduced in the iDASH Challenge to be more representative of real world scenarios to allow for a more comprehensive evaluation. We then conduct a sensitivity analysis of our method with respect to several state-of-the-art methods using a dataset of 400,000 positions in Chromosome 10 for 500 individuals from Phase 3 of the 1000 Genomes Project. All methods are evaluated for utility, privacy and efficiency. Our method achieves better performance than all state-of-the-art methods, irrespective of how key factors (e.g., the allele frequency in the population, the size of the pool and utility weights) change from the original parameters of the problem. We further illustrate that it is possible for our method to exhibit subpar performance under special cases of allele query sequences. However, we show our method can be extended to address this issue when the query sequence is fixed and known a priori to the data custodian, so that they may plan stage their

  15. The Southeastern Minnesota Beacon Project for Community-driven Health Information Technology: Origins, Achievements, and Legacy.

    Science.gov (United States)

    Chute, Christopher G; Hart, Lacey A; Alexander, Alex K; Jensen, Daniel W

    2014-01-01

    The Southeastern (SE) Minnesota Beacon organized all the health care providers, county public health organizations, and school districts in the deployment and integration of health information exchange (HIE) and targeted health communication around childhood asthma and diabetes. The community cooperated to establish a clinical data repository for all residents in the 11-county region. Through this community of practice approach that involved traditional and nontraditional providers, the SE Minnesota Beacon was able to realize unique applications of this technology. This manuscript overviews the associated organization and infrastructure of this community collaboration. The Office of the National Coordinator for Health Information Technology (ONC), as part of the American Recovery and Reinvestment Act of 2009 (ARRA) stimulus, established 17 projects throughout the United States targeting the introduction and meaningful use of health information technology (HIT). These 17 communities were intended to serve as an example of what could be accomplished. The SE Minnesota Beacon is one of these communities. The community ultimately opted for peer-to-peer HIE, using Nationwide Health Information Network (NwHIN) Connect software. The clinical data repository was established using the infrastructure developed by the Regenstrief Institute, which operated as a trusted third party. As an extension to HIE, the consortium of county public health departments created a patient data portal for use by school nurses and parents. Childhood asthma was addressed by creating, exchanging, and maintaining an "asthma action plan" for each affected child, shared throughout the community, including through the patient portal. Diabetes management introduced patient treatment decision tools and patient quality of life measures, facilitating care. Influenza vaccination was enhanced by large-scale community reporting in partnership with the state vaccination registry. The methodology and

  16. Enzymatic Amplification of DNA/RNA Hybrid Molecular Beacon Signaling in Nucleic Acid Detection

    OpenAIRE

    Jacroux, Thomas; Rieck, Daniel C.; Cui, Rong; Ouyang, Yexin; Dong, Wen-Ji

    2012-01-01

    A rapid assay operable under isothermal or non-isothermal conditions is described wherein the sensitivity of a typical molecular beacon (MB) system is improved by utilizing thermostable RNase H to enzymatically cleave an MB comprised of a DNA stem and RNA loop (R/D-MB). Upon hybridization of the R/D-MB to target DNA, there was a modest increase in fluorescence intensity (~5.7x above background) due to an opening of the probe and concomitant reduction in the Förster resonance energy transfer e...

  17. In situ exposure to non-directional beacons for air traffic control.

    Science.gov (United States)

    Joseph, Wout; Goeminne, Francis; Vermeeren, Günter; Verloock, Leen; Martens, Luc

    2012-04-01

    In situ electromagnetic field exposure of workers and the general public due to non-directional beacons (NDB) for air traffic control is assessed and characterized. For occupational exposure, the maximal measured electric field value is 881.6 V/m and the maximal magnetic field value is 9.1 A/m. The maximum electric fields exceed the International Commission on Non-Ionizing Radiation Protection (ICNIRP) reference levels at all seven NDB sites, and the magnetic fields at two of the seven NDB sites (occupational exposure). Recommendations and compliance distances for workers and the general public are provided. © 2012 Wiley Periodicals, Inc.

  18. Observability analysis of 2D single-beacon navigation in the presence of constant currents for two classes of maneuvers

    Digital Repository Service at National Institute of Oceanography (India)

    Crasta, N.; Bayat, M.; Aguiar, A.P.; Pascoal, A.M.

    . In particular, xc = 0 represents a circular motion about the beacon with radius v ω−1. The following result characterizes set of indistinguishable states for the system (5.1)-(5.2) subject to input class Ucir. Proposition 5.6. Consider the system (5...) = npi + 0.5 (−1)n pi, n ∈ Z. Notice also that under this condition the motion is a circular motion around the beacon. The following corollary follows from propositions 5.3 and 5.6. Corollary 5.8. Consider x0 ∈ M. Then (4.1)-(4.2) is observable...

  19. Wireless radio a history

    CERN Document Server

    Coe, Lewis

    2006-01-01

    ""Informative...recommended""--Choice; ""interesting...a good read...well worth reading""--Contact Magazine. This history first looks at Marconi's wireless communications system and then explores its many applications, including marine radio, cellular telephones, police and military uses, television and radar. Radio collecting is also discussed, and brief biographies are provided for the major figures in the development and use of the wireless.

  20. ¿Radios ciudadanas?

    OpenAIRE

    López Vigil, José Ignacio

    1998-01-01

    Educativas, sindicales, populares, comunitarias, libres, rebeldes, participativas, alternativas, alterativas, han sido las denominaciones de la radio cuando su proyecto está al servicio de la gente. Palabras apropiadas y nobles -dice elautor-pero devaluadas, a las que ahora se agrega la radio ciudadana, para relievarla como ejercicio depoder y espacio de verdadera participación de la genteenla vida de su nación.

  1. Classics in radio astronomy

    CERN Document Server

    Sullivan, Woodruff Turner

    1982-01-01

    Radio techniques were the nrst to lead astronomy away from the quiescent and limited Universe revealed by traditional observations at optical wave­ lengths. In the earliest days of radio astronomy, a handful of radio physicists and engineers made one startling discovery after another as they opened up the radio sky. With this collection of classic papers and the extensive intro­ ductory material, the reader can experience these exciting discoveries, as well as understand the developing techniques and follow the motivations which prompted the various lines of inquiry. For instance he or she will follow in detail the several attempts to detect radio waves from the sun at the turn of the century; the unravelling by Jansky of a "steady hiss type static"; the incredible story of Reber who built a 9 meter dish in his backyard in 1937 and then mapped the Milky Way; the vital discoveries by Hey and colleagues of radio bursts from the Sun and of a discrete source in the constellation of Cygnus; the development of re...

  2. Solar radio observations and interpretations

    International Nuclear Information System (INIS)

    Rosenberg, H.

    1976-01-01

    The recent solar radio observations related to flares are reviewed for the frequency range of a few kilohertz to several gigahertz. The analysis of the radio data leads to boundary conditions on the acceleration processes which are responsible for the fast particles which cause radio emission. The role and cause of plasma turbulence at the plasma-frequency and at much lower frequencies is discussed in relation to the acceleration processes and the radio emission mechanisms for the various radio bursts. (author)

  3. Preliminary Statistics from the NASA Alphasat Beacon Receiver in Milan, Italy

    Science.gov (United States)

    Nessel, James; Zemba, Michael; Morse, Jacquelynne; Luini, Lorenzo; Riva, Carlo

    2015-01-01

    NASA Glenn Research Center (GRC) and the Politecnico di Milano (POLIMI) have initiated a joint propagation campaign within the framework of the Alphasat propagation experiment to characterize rain attenuation, scintillation, and gaseous absorption effects of the atmosphere in the 40 gigahertz band. NASA GRC has developed and installed a K/Q-band (20/40 gigahertz) beacon receiver at the POLIMI campus in Milan, Italy, which receives the 20/40 gigahertz signals broadcast from the Alphasat Aldo Paraboni TDP no. 5 beacon payload. The primary goal of these measurements is to develop a physical model to improve predictions of communications systems performance within the Q-band. Herein, we provide an overview of the design and data calibration procedure, and present 6 months of preliminary statistics of the NASA propagation terminal, which has been installed and operating in Milan since May 2014. The Q-band receiver has demonstrated a dynamic range of 40 decibels at an 8-hertz sampling rate. A weather station with an optical disdrometer is also installed to characterize rain drop size distribution for correlation with physical based models.

  4. Performance Evaluation of Beacon-Enabled Mode for IEEE 802.15.4 Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    M. Udin Harun Al Rasyid

    2013-12-01

    Full Text Available IEEE 802.15.5 standard support structure of star and peer-to-peer network formation. Strating from these, the cluster tree network can be built as a special case of peer-to-peer network to increse coverage area. In this paper, we provide an performance evaluation of beacon- enabled mode for IEEE 802.15.4 wireless sensor network on star and cluster topology in order to get the maximum result to apply the appropriate topology model as needed. We conduct analysis on each topology model by using the numbers of nodes from 10 nodes to 100 nodes to analyze throughput, delay, energy consumption, and probability success packet by using NS2 simulator. The simulation results show that the throughput and the probability of success packet of cluster topology are higher than that of star topology, and the energy consumption of cluster topology is lesser than that of star topology. However, cluster topology increases the delay more than star topology. Keywords: IEEE 802.15.4, wireless sensor network, beacon-enabled mode, topology, csma/ca

  5. Secure Utilization of Beacons and UAVs in Emergency Response Systems for Building Fire Hazard.

    Science.gov (United States)

    Seo, Seung-Hyun; Choi, Jung-In; Song, Jinseok

    2017-09-25

    An intelligent emergency system for hazard monitoring and building evacuation is a very important application area in Internet of Things (IoT) technology. Through the use of smart sensors, such a system can provide more vital and reliable information to first-responders and also reduce the incidents of false alarms. Several smart monitoring and warning systems do already exist, though they exhibit key weaknesses such as a limited monitoring coverage and security, which have not yet been sufficiently addressed. In this paper, we propose a monitoring and emergency response method for buildings by utilizing beacons and Unmanned Aerial Vehicles (UAVs) on an IoT security platform. In order to demonstrate the practicability of our method, we also implement a proof of concept prototype, which we call the UAV-EMOR (UAV-assisted Emergency Monitoring and Response) system. Our UAV-EMOR system provides the following novel features: (1) secure communications between UAVs, smart sensors, the control server and a smartphone app for security managers; (2) enhanced coordination between smart sensors and indoor/outdoor UAVs to expand real-time monitoring coverage; and (3) beacon-aided rescue and building evacuation.

  6. Palindromic Molecule Beacon-Based Cascade Amplification for Colorimetric Detection of Cancer Genes.

    Science.gov (United States)

    Shen, Zhi-Fa; Li, Feng; Jiang, Yi-Fan; Chen, Chang; Xu, Huo; Li, Cong-Cong; Yang, Zhe; Wu, Zai-Sheng

    2018-03-06

    A highly sensitive and selective colorimetric assay based on a multifunctional molecular beacon with palindromic tail (PMB) was proposed for the detection of target p53 gene. The PMB probe can serve as recognition element, primer, and polymerization template and contains a nicking site and a C-rich region complementary to a DNAzyme. In the presence of target DNA, the hairpin of PMB is opened, and the released palindromic tails intermolecularly hybridize with each other, triggering the autonomous polymerization/nicking/displacement cycles. Although only one type of probe is involved, the system can execute triple and continuous polymerization strand displacement amplifications, generating large amounts of G-quadruplex fragments. These G-rich fragments can bind to hemin and form the DNAzymes that possess the catalytic activity similar to horseradish peroxidase, catalyzing the oxidation of ABTS by H 2 O 2 and producing the colorimetric signal. Utilizing the newly proposed sensing system, target DNA can be detected down to 10 pM with a linear response range from 10 pM to 200 nM, and mutant target DNAs are able to be distinguished even by the naked eye. The desirable detection sensitivity, high specificity, and operation convenience without any separation step and chemical modification demonstrate that the palindromic molecular beacon holds the potential for detecting and monitoring a variety of nucleic acid-related biomarkers.

  7. A Two-Layer Method for Sedentary Behaviors Classification Using Smartphone and Bluetooth Beacons.

    Science.gov (United States)

    Cerón, Jesús D; López, Diego M; Hofmann, Christian

    2017-01-01

    Among the factors that outline the health of populations, person's lifestyle is the more important one. This work focuses on the caracterization and prevention of sedentary lifestyles. A sedentary behavior is defined as "any waking behavior characterized by an energy expenditure of 1.5 METs (Metabolic Equivalent) or less while in a sitting or reclining posture". To propose a method for sedentary behaviors classification using a smartphone and Bluetooth beacons considering different types of classification models: personal, hybrid or impersonal. Following the CRISP-DM methodology, a method based on a two-layer approach for the classification of sedentary behaviors is proposed. Using data collected from a smartphones' accelerometer, gyroscope and barometer; the first layer classifies between performing a sedentary behavior and not. The second layer of the method classifies the specific sedentary activity performed using only the smartphone's accelerometer and barometer data, but adding indoor location data, using Bluetooth Low Energy (BLE) beacons. To improve the precision of the classification, both layers implemented the Random Forest algorithm and the personal model. This study presents the first available method for the automatic classification of specific sedentary behaviors. The layered classification approach has the potential to improve processing, memory and energy consumption of mobile devices and wearables used.

  8. Perancangan Prototipe Receiver Beacon Black Box Locator Acoustic 37,5 kHz Pingers

    Directory of Open Access Journals (Sweden)

    RUSTAMAJI RUSTAMAJI

    2016-01-01

    When an aircraft caught in an accident and crashes into the water, its location can be detected using a device called a receiver beacon black box locator acoustic (pingers receiver. The pingers receiver functioned as a reciever signal with 37,5 kHz ± 1 kHz frequency from trnasmitter pingers or Underwater Locator Beacon (ULB which is on air plane black blox. In this research made design pingers receiver composed of a series of  Band Pass Filter (BPF, envelope detector, audio amplifier, and loud speaker. The signal of 37,5 kHz ± 1 kHz  frequency sent by pingers transmitter will bereceived by pingers receiver, after which the signal will be processed by the Band Pass Filter (BPF circuit before being detected by envelope detector for take back the signal information which like pulse signal with 10ms width and 1 second interval as pingers signal tha can  be to  be heard by human ear. Based on the  design that  was made, the signal ouput generated by the prototype has a 14 ms width with 1 second interval. Keywords: pingers receiver, band pass filter (BPF, envelope detector, loud speaker.

  9. Tools of radio astronomy

    CERN Document Server

    Wilson, Thomas L; Hüttemeister, Susanne

    2013-01-01

    This 6th edition of “Tools of Radio Astronomy”, the most used introductory text in radio astronomy, has been revised to reflect the current state of this important branch of astronomy. This includes the use of satellites, low radio frequencies, the millimeter/sub-mm universe, the Cosmic Microwave Background and the increased importance of mm/sub-mm dust emission. Several derivations and presentations of technical aspects of radio astronomy and receivers, such as receiver noise, the Hertz dipole and  beam forming have been updated, expanded, re-worked or complemented by alternative derivations. These reflect advances in technology. The wider bandwidths of the Jansky-VLA and long wave arrays such as LOFAR and mm/sub-mm arrays such as ALMA required an expansion of the discussion of interferometers and aperture synthesis. Developments in data reduction algorithms have been included. As a result of the large amount of data collected in the past 20 years, the discussion of solar system radio astronomy, dust em...

  10. 75 FR 20364 - Public Buildings Service; Key Largo Beacon Annex Site; Key Largo, FL; Transfer of Property

    Science.gov (United States)

    2010-04-19

    ... GENERAL SERVICES ADMINISTRATION [Wildlife Order 187; 4-D-FL-1218] Public Buildings Service; Key Largo Beacon Annex Site; Key Largo, FL; Transfer of Property Pursuant to section 2 of Public Law 537, 80th Congress, approved May 19, 1948 (16 U.S.C. 667c), notice is hereby given that: 1. The General...

  11. Guiding Math Students to Campus Services: An Impact Evaluation of the Beacon Program at South Texas College

    Science.gov (United States)

    Visher, Mary; Butcher, Kristin F.; Cerna, Oscar S.

    2011-01-01

    This research rigorously evaluates whether a low-cost intervention can improve students' performance in developmental math. The "Beacon Mentoring Program" was developed at South Texas College by professors, administrators, and staff at the college. Surveys of students revealed that many did not have someone on campus whom they felt they…

  12. Beacon Charter School Needs a School: A Case of Capital Outlay of Charters in a Public District

    Science.gov (United States)

    Wronowski, Meredith L.

    2017-01-01

    The case study presented below is a representation of a real-world, ongoing situation involving a public school district's capital outlay for charter schools within its boundaries. One particular charter, Beacon Charter School, was promised a permanent building by the public school district that also acts as its authorizer. However, recent events…

  13. A molecular-beacon-based asymmetric PCR assay for easy visualization of amplicons in the diagnosis of trichomoniasis.

    Science.gov (United States)

    Sonkar, Subash C; Sachdev, Divya; Mishra, Prashant K; Kumar, Anita; Mittal, Pratima; Saluja, Daman

    2016-12-15

    The currently available nucleic acid amplification tests (NAATs) for trichomoniasis are accurate, quick and confirmative with superior sensitivity than traditional culture-based microbiology assays. However, these assays are associated with problems of carry over contamination, false positive results, requirement of technical expertise for performance and detection of end product. Hence, a diagnostic assay with easy visualization of the amplified product will be profitable. An in-house, rapid, sensitive, specific molecular-beacon-based PCR assay, using primers against pfoB gene of Trichomonas vaginalis, was developed and evaluated using dry ectocervical swabs (n=392) from symptomatic females with vaginal discharge. Total DNA was isolated and used as template for the PCR assays. The performance and reproducibility of PCR assay was evaluated by composite reference standard (CRS). For easy visualization of the amplified product, molecular-beacon was designed and amplicons were visualized directly using fluorescent handheld dark reader or by Micro-Plate Reader. Molecular-beacons are single-stranded hairpin shaped nucleic acid probes composed of a stem, with fluorophore/quencher pair and a loop region complementary to the desired DNA. The beacon-based PCR assay designed in the present study is highly specific as confirmed by competition experiments and extremely sensitive with detection limit of 20fg of genomic DNA (3-4 pathogens). The minimum infrastructure requirement and ease to perform the assay makes this method highly useful for resource poor countries for better disease management. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. A quencher-free molecular beacon design based on pyrene excimer fluorescence using pyrene-labeled UNA (unlocked nucleic acid)

    DEFF Research Database (Denmark)

    Karlsen, Kasper Kannegård; Okholm, Anders Hauge; Kjems, Jørgen

    2013-01-01

    A quencher-free molecular beacon capable of generating pyrene excimer fluorescence has been constructed using strategically positioned pyrene-UNA monomers. Hybridization of a fully complementary RNA target was accompanied by a pyrene excimer emission increase of more than 900%, and detection of RNA...

  15. BEACON/MOD2A: a computer program for subcompartment analysis of nuclear reactor containment. A user's manual

    International Nuclear Information System (INIS)

    Wells, R.A.

    1979-03-01

    The BEACON code is a Best Estimate Advanced Containment code which being developed by EG and G, Idaho, Inc., at the Idaho National Engineering Laboratory. The program is designed to perform a best estimate analysis of the flow of a mixture of air, water, and steam in a nuclear reactor containment system under loss-of-coolant accident conditions. The code can simulate two-component, two-phase fluid flow in complex geometries using a combination of two-dimensional, one-dimensional, and lumped-parameter representations for the various parts of the system. The current version of BEACON, which is designated BEACON/MOD2A, contains mass and heat transfer models for wall film and for wall conduction. It is suitable for the evaluation of short term transients in PWR dry containment systems. This manual describes the models employed in BEACON/MOD2A and specifies code implementation requirements. It provides application information for input data preparation and for output data interpretation

  16. Design and Practical Evaluation of a Family of Lightweight Protocols for Heterogeneous Sensing through BLE Beacons in IoT Telemetry Applications.

    Science.gov (United States)

    Hernández-Rojas, Dixys L; Fernández-Caramés, Tiago M; Fraga-Lamas, Paula; Escudero, Carlos J

    2017-12-27

    The Internet of Things (IoT) involves a wide variety of heterogeneous technologies and resource-constrained devices that interact with each other. Due to such constraints, IoT devices usually require lightweight protocols that optimize the use of resources and energy consumption. Among the different commercial IoT devices, Bluetooth and Bluetooth Low Energy (BLE)-based beacons, which broadcast periodically certain data packets to notify their presence, have experienced a remarkable growth, specially due to their application in indoor positioning systems. This article proposes a family of protocols named Lightweight Protocol for Sensors (LP4S) that provides fast responses and enables plug-and-play mechanisms that allow IoT telemetry systems to discover new nodes and to describe and auto-register the sensors and actuators connected to a beacon. Thus, three protocols are defined depending on the beacon hardware characteristics: LP4S-6 (for resource-constraint beacons), LP4S-X (for more powerful beacons) and LP4S-J (for beacons able to run complex firmware). In order to demonstrate the capabilities of the designed protocols, the most restrictive (LP4S-6) is tested after implementing it for a telemetry application in a beacon based on Eddystone (Google's open beacon format). Thus, the beacon specification is extended in order to increase its ability to manage unlimited sensors in a telemetry system without interfering in its normal operation with Eddystone frames. The performed experiments show the feasibility of the proposed solution and its superiority, in terms of latency and energy consumption, with respect to approaches based on Generic Attribute Profile (GATT) when multiple users connect to a mote or in scenarios where latency is not a restriction, but where low-energy consumption is essential.

  17. Design and Practical Evaluation of a Family of Lightweight Protocols for Heterogeneous Sensing through BLE Beacons in IoT Telemetry Applications

    Science.gov (United States)

    2017-01-01

    The Internet of Things (IoT) involves a wide variety of heterogeneous technologies and resource-constrained devices that interact with each other. Due to such constraints, IoT devices usually require lightweight protocols that optimize the use of resources and energy consumption. Among the different commercial IoT devices, Bluetooth and Bluetooth Low Energy (BLE)-based beacons, which broadcast periodically certain data packets to notify their presence, have experienced a remarkable growth, specially due to their application in indoor positioning systems. This article proposes a family of protocols named Lightweight Protocol for Sensors (LP4S) that provides fast responses and enables plug-and-play mechanisms that allow IoT telemetry systems to discover new nodes and to describe and auto-register the sensors and actuators connected to a beacon. Thus, three protocols are defined depending on the beacon hardware characteristics: LP4S-6 (for resource-constraint beacons), LP4S-X (for more powerful beacons) and LP4S-J (for beacons able to run complex firmware). In order to demonstrate the capabilities of the designed protocols, the most restrictive (LP4S-6) is tested after implementing it for a telemetry application in a beacon based on Eddystone (Google’s open beacon format). Thus, the beacon specification is extended in order to increase its ability to manage unlimited sensors in a telemetry system without interfering in its normal operation with Eddystone frames. The performed experiments show the feasibility of the proposed solution and its superiority, in terms of latency and energy consumption, with respect to approaches based on Generic Attribute Profile (GATT) when multiple users connect to a mote or in scenarios where latency is not a restriction, but where low-energy consumption is essential. PMID:29280975

  18. Design and Practical Evaluation of a Family of Lightweight Protocols for Heterogeneous Sensing through BLE Beacons in IoT Telemetry Applications

    Directory of Open Access Journals (Sweden)

    Dixys L. Hernández-Rojas

    2017-12-01

    Full Text Available The Internet of Things (IoT involves a wide variety of heterogeneous technologies and resource-constrained devices that interact with each other. Due to such constraints, IoT devices usually require lightweight protocols that optimize the use of resources and energy consumption. Among the different commercial IoT devices, Bluetooth and Bluetooth Low Energy (BLE-based beacons, which broadcast periodically certain data packets to notify their presence, have experienced a remarkable growth, specially due to their application in indoor positioning systems. This article proposes a family of protocols named Lightweight Protocol for Sensors (LP4S that provides fast responses and enables plug-and-play mechanisms that allow IoT telemetry systems to discover new nodes and to describe and auto-register the sensors and actuators connected to a beacon. Thus, three protocols are defined depending on the beacon hardware characteristics: LP4S-6 (for resource-constraint beacons, LP4S-X (for more powerful beacons and LP4S-J (for beacons able to run complex firmware. In order to demonstrate the capabilities of the designed protocols, the most restrictive (LP4S-6 is tested after implementing it for a telemetry application in a beacon based on Eddystone (Google’s open beacon format. Thus, the beacon specification is extended in order to increase its ability to manage unlimited sensors in a telemetry system without interfering in its normal operation with Eddystone frames. The performed experiments show the feasibility of the proposed solution and its superiority, in terms of latency and energy consumption, with respect to approaches based on Generic Attribute Profile (GATT when multiple users connect to a mote or in scenarios where latency is not a restriction, but where low-energy consumption is essential.

  19. Galactic radio astronomy

    CERN Document Server

    Sofue, Yoshiaki

    2017-01-01

    This book is a concise primer on galactic radio astronomy for undergraduate and graduate students, and provides wide coverage of galactic astronomy and astrophysics such as the physics of interstellar matter and the dynamics and structure of the Milky Way Galaxy and galaxies. Radio astronomy and its technological development have led to significant progress in galactic astronomy and contributed to understanding interstellar matter and galactic structures. The book begins with the fundamental physics of radio-wave radiation, i.e., black body radiation, thermal emission, synchrotron radiation, and HI and molecular line emissions. The author then gives overviews of ingredients of galactic physics, including interstellar matter such as the neutral (HI), molecular hydrogen, and ionized gases, as well as magnetic fields in galaxies. In addition, more advanced topics relevant to the Galaxy and galaxies are also contained here: star formation, supernova remnants, the Galactic Center and black holes, galactic dynamics...

  20. Radio structure in quasars

    International Nuclear Information System (INIS)

    Barthel, P.D.

    1984-01-01

    In this thesis, observational attention is given to the extended extragalactic radio sources associated with quasars. The isolated compact radio sources, often identified with quasars, are only included in the discussions. Three aspects of the radio structure in quasars and their cosmic evolution are considered: a study of the parsec scale morphology in quasar cores, in relation to the extended morphologies; an investigation of possible epoch dependent hotspot properties as well as a more detailed investigation of this fine scale structure; a VLA project was carried out to obtain morphological information on scales of 0.5 arcsec on high redshift quasars and to investigate possible epoch dependent morphological properties. MERLIN observations at 0.1 arcsec resolution to supplement the VLA data were initiated. (Auth.)

  1. Radio Emission from Supernovae

    International Nuclear Information System (INIS)

    Weiler, Kurt W.; Panagia, Nino; Sramek, Richard A.; Van Dyk, Schuyler D.; Williams, Christopher L.; Stockdale, Christopher J.; Kelley, Matthew T.

    2009-01-01

    Study of radio supernovae over the past 27 years includes more than three dozen detected objects and more than 150 upper limits. From this work it is possible to identify classes of radio properties, demonstrate conformance to and deviations from existing models, estimate the density and structure of the circumstellar material and, by inference, the evolution of the presupernova stellar wind, and reveal the last stages of stellar evolution before explosion. It is also possible to detect ionized hydrogen along the line of sight, to demonstrate binary properties of the presupernova stellar system, and to detect dumpiness of the circumstellar material.

  2. Radio emission from Jupiter

    International Nuclear Information System (INIS)

    Velusamy, T.

    1976-01-01

    The basic features of the different radio emissions from the planet Jupiter are reviewed. These radio emissions characterized into three types as thermal, decimetric and decametric, are discussed. The coherent emission mechanism for the origin of the decametric bursts and the acceleration mechanism for relativistic electrons in the decimetric radiation have not been properly understood. The emissions are much related to the magnetic field of Jupiter. The system III rotation period for Jupiter has been calculated as 092 55 m 29.74 S. (A.K.)

  3. ¿Radios Comunitarias?

    OpenAIRE

    José Ignacio López Vigil

    2015-01-01

    Varias han sido las denominaciones dadas a la radio cuando su proyecto está al servicio de la gente. Palabras apropiadas pero devaluadas al decir del autor, a las que ahora se suma otras radios ciudadanas. Ciudadana para relievarla como ejercicio de poder y espacio de verdadera participación de la gente en la vida de su nación. Ciudadanos son los que piensan con cabeza propia y pesan en la opinión pública. Presenta una sinopsis de la historia de éstas desde 1974. Señala que la competencia obl...

  4. Data governance and data sharing agreements for community-wide health information exchange: lessons from the beacon communities.

    Science.gov (United States)

    Allen, Claudia; Des Jardins, Terrisca R; Heider, Arvela; Lyman, Kristin A; McWilliams, Lee; Rein, Alison L; Schachter, Abigail A; Singh, Ranjit; Sorondo, Barbara; Topper, Joan; Turske, Scott A

    2014-01-01

    Unprecedented efforts are underway across the United States to electronically capture and exchange health information to improve health care and population health, and reduce costs. This increased collection and sharing of electronic patient data raises several governance issues, including privacy, security, liability, and market competition. Those engaged in such efforts have had to develop data sharing agreements (DSAs) among entities involved in information exchange, many of whom are "nontraditional" health care entities and/or new partners. This paper shares lessons learned based on the experiences of six federally funded communities participating in the Beacon Community Cooperative Agreement Program, and offers guidance for navigating data governance issues and developing DSAs to facilitate community-wide health information exchange. While all entities involved in electronic data sharing must address governance issues and create DSAs accordingly, until recently little formal guidance existed for doing so - particularly for community-based initiatives. Despite this lack of guidance, together the Beacon Communities' experiences highlight promising strategies for navigating complex governance issues, which may be useful to other entities or communities initiating information exchange efforts to support delivery system transformation. For the past three years, AcademyHealth has provided technical assistance to most of the 17 Beacon Communities, 6 of whom contributed to this collaborative writing effort. Though these communities varied widely in terms of their demographics, resources, and Beacon-driven priorities, common themes emerged as they described their approaches to data governance and DSA development. The 6 Beacon Communities confirmed that DSAs are necessary to satisfy legal and market-based concerns, and they identified several specific issues, many of which have been noted by others involved in network data sharing initiatives. More importantly, these

  5. [Molecular beacon based PNA-FISH method combined with fluorescence scanning for rapid detection of Listeria monocytogenes].

    Science.gov (United States)

    Wu, Shan; Zhang, Xiaofeng; Shuai, Jiangbing; Li, Ke; Yu, Huizhen; Jin, Chenchen

    2016-07-04

    To simplify the PNA-FISH (Peptide nucleic acid-fluorescence in situ hybridization) test, molecular beacon based PNA probe combined with fluorescence scanning detection technology was applied to replace the original microscope observation to detect Listeria monocytogenes The 5′ end and 3′ end of the L. monocytogenes specific PNA probes were labeled with the fluorescent group and the quenching group respectively, to form a molecular beacon based PNA probe. When PNA probe used for fluorescence scanning and N1 treatment as the control, the false positive rate was 11.4%, and the false negative rate was 0; when N2 treatment as the control, the false positive rate decreased to 4.3%, but the false negative rate rose to 18.6%. When beacon based PNA probe used for fluorescence scanning, taken N1 treatment as blank control, the false positive rate was 8.6%, and the false negative rate was 1.4%; taken N2 treatment as blank control, the false positive rate was 5.7%, and the false negative rate was 1.4%. Compared with PNA probe, molecular beacon based PNA probe can effectively reduce false positives and false negatives. The success rates of hybridization of the two PNA probes were 83.3% and 95.2% respectively; and the rates of the two beacon based PNA probes were 91.7% and 90.5% respectively, which indicated that labeling the both ends of the PNA probe dose not decrease the hybridization rate with the target bacteria. The combination of liquid phase PNA-FISH and fluorescence scanning method, can significantly improve the detection efficiency.

  6. Beacon of Hope? Lessons Learned from Efforts to Reduce Civilian Deaths from Police Shootings in an Australian State.

    Science.gov (United States)

    Saligari, Jessica; Evans, Richard

    2016-04-01

    In the 1990s, the police service in Victoria, Australia, faced a crisis of community confidence due to a spate of civilian deaths from police shootings. In that decade, twice as many civilians died at the hands of the police in Victoria than in every other Australian state combined. Most of those killed were mentally ill and affected by drugs and alcohol, and were rarely a serious threat except to themselves. The problem was also almost entirely an urban phenomenon. Shootings in rural communities, where mentally ill people were more likely to be personally known to local police, were (and remain) almost unknown. The large number of fatalities was recognised as a serious threat to public confidence, and Victoria Police introduced a ground-breaking training programme, Operation Beacon. Operating procedures and weapons training were fundamentally changed, to focus on de-escalation of conflict and avoiding or minimising police use of force. In the short term, Operation Beacon was successful. Shooting incidents were dramatically reduced. However, during the first decade of the new century, the number of civilians being killed again increased. This article examines Operation Beacon, both as a successful model for reducing civilian deaths at the hand of police and as a cautionary tale for police reform. We argue that the lessons of Operation Beacon have been gradually forgotten and that old habits and attitudes resurfaced. Fatal shootings of mentally ill civilians can be prevented, but if success is to be other than temporary, the Beacon philosophy must be continually reemphasised by police management.

  7. Spectrum management and radio resource management considering cognitive radio systems

    NARCIS (Netherlands)

    Haartsen, J.C.; Wieweg, Lasse; Huschke, Jörg

    2005-01-01

    International fora and some national administrations define a cognitive radio (CR) as a pioneering radio communication system that would be capable of altering and adapting its transmitter and receiver parameters based on communication and the exchange of information with related detectable radio

  8. Compact radio sources

    International Nuclear Information System (INIS)

    Altschuler, D.R.

    1975-01-01

    Eighty-seven compact radio sources were monitored between 1971 and 1974 with the National Radio Astronomy Observatory interferometer. Both flux density and polarization were measured at intervals of about one month at wavelengths of 3.7 and 11.1 cms. Forty-four sources showed definite variability in their total and/or polarized flux density. The variations in polarization were of a shorter time scale than the corresponding flux density variations. Some of the qualitative features of an expanding source model were observed. The data suggest that some form of injection of relativistic electrons is taking place. The absence of significant depolarization in the variable sources indicates that only a small fraction of the mass of the radio outburst is in the form of non-relativistic plasma. Some of the objects observed belong to the BL-Lacertal class. It is shown that this class is very inhomogeneous in its radio properties. For the violently variable BL-Lacertal type objects the spectrum, flux variations and polarization data strongly suggest that these are very young objects

  9. Valuing commercial radio licences

    NARCIS (Netherlands)

    Kerste, M.; Poort, J.; van Eijk, N.

    2011-01-01

    Within the EU Regulatory Framework, licensees for commercial radio broadcasting may be charged a fee to ensure optimal allocation of scarce resources but not to maximize public revenues. In this paper, it is described how such a fee can be determined for the purpose of licence renewal or extension.

  10. Radio Frequency Identification

    Indian Academy of Sciences (India)

    Radio Frequency Identification (RFID) has been around sinceearly 2000. Its use has currently become commonplace as thecost of RFID tags has rapidly decreased. RFID tags have alsobecome more 'intelligent' with the incorporation of processorsand sensors in them. They are widely used now in manyinnovative ways.

  11. Nanolensed Fast Radio Bursts

    Science.gov (United States)

    Eichler, David

    2017-12-01

    It is suggested that fast radio bursts can probe gravitational lensing by clumpy dark matter objects that range in mass from 10-3 M ⊙-102 M ⊙. They may provide a more sensitive probe than observations of lensings of objects in the Magellanic Clouds, and could find or rule out clumpy dark matter with an extended mass spectrum.

  12. AMATEUR "HAM" RADIO

    Science.gov (United States)

    these cooler months. Did you know your body can cool 25 times faster in water than in air? That water code at 13 or 20 words-per-minute will no longer be required to obtain amateur radio operating be found by contacting the ARRL or using an Internet search engine to search on such topics as "

  13. Radio images of the planets

    International Nuclear Information System (INIS)

    De Pater, I.

    1990-01-01

    Observations at radio wavelengths make possible detailed studies of planetary atmospheres, magnetospheres, and surface layers. The paper addresses the question of what can be learned from interferometric radio images of planets. Results from single-element radio observations are also discussed. Observations of both the terrestrial and the giant planets are considered. 106 refs

  14. Isothermal amplification detection of nucleic acids by a double-nicked beacon.

    Science.gov (United States)

    Shi, Chao; Zhou, Meiling; Pan, Mei; Zhong, Guilin; Ma, Cuiping

    2016-03-01

    Isothermal and rapid amplification detection of nucleic acids is an important technology in environmental monitoring, foodborne pathogen detection, and point-of-care clinical diagnostics. Here we have developed a novel method of isothermal signal amplification for single-stranded DNA (ssDNA) detection. The ssDNA target could be used as an initiator, coupled with a double-nicked molecular beacon, to originate amplification cycles, achieving cascade signal amplification. In addition, the method showed good specificity and strong anti-jamming capability. Overall, it is a one-pot and isothermal strand displacement amplification method without the requirement of a stepwise procedure, which greatly simplifies the experimental procedure and decreases the probability of contamination of samples. With its advantages, the method would be very useful to detect nucleic acids in point-of-care or field use. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Simple fluorescence-based detection of protein kinase A activity using a molecular beacon probe.

    Science.gov (United States)

    Ma, Changbei; Lv, Xiaoyuan; Wang, Kemin; Jin, Shunxin; Liu, Haisheng; Wu, Kefeng; Zeng, Weimin

    2017-11-02

    Protein kinase A was detected by quantifying the amount of ATP used after a protein kinase reaction. The ATP assay was performed using the T4 DNA ligase and a molecular beacon (MB). In the presence of ATP, DNA ligase catalyzed the ligation of short DNA. The ligation product then hybridized to MB, resulting in a fluorescence enhancement of the MB. This assay was capable of determining protein kinase A in the range of 12.5∼150 nM, with a detection limit of 1.25 nM. Furthermore, this assay could also be used to investigate the effect of genistein on protein kinase A. It was a universal, non-radioisotopic, and homogeneous method for assaying protein kinase A.

  16. Considerations for Community-Based mHealth Initiatives: Insights From Three Beacon Communities

    Science.gov (United States)

    2013-01-01

    Mobile health (mHealth) is gaining widespread attention for its potential to engage patients in their health and health care in their daily lives. Emerging evidence suggests that mHealth interventions can be used effectively to support behavior change, but numerous challenges remain when implementing these programs at the community level. This paper provides an overview of considerations when implementing community-based mHealth initiatives, based on the experiences of three Beacon Communities across the United States that have launched text messaging (short message service, SMS) pilot programs aimed at diabetes risk reduction and disease management. The paper addresses lessons learned and suggests strategies to overcome challenges related to developing text message content, conducting marketing and outreach, enrolling participants, engaging providers, evaluating program effectiveness, and sustaining and scaling the programs. PMID:24128406

  17. Facile conversion of ATP-binding RNA aptamer to quencher-free molecular aptamer beacon.

    Science.gov (United States)

    Park, Yoojin; Nim-Anussornkul, Duangrat; Vilaivan, Tirayut; Morii, Takashi; Kim, Byeang Hyean

    2018-01-15

    We have developed RNA-based quencher-free molecular aptamer beacons (RNA-based QF-MABs) for the detection of ATP, taking advantage of the conformational changes associated with ATP binding to the ATP-binding RNA aptamer. The RNA aptamer, with its well-defined structure, was readily converted to the fluorescence sensors by incorporating a fluorophore into the loop region of the hairpin structure. These RNA-based QF-MABs exhibited fluorescence signals in the presence of ATP relative to their low background signals in the absence of ATP. The fluorescence emission intensity increased upon formation of a RNA-based QF-MAB·ATP complex. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Pyrene functionalized molecular beacon with pH-sensitive i-motif in a loop.

    Science.gov (United States)

    Dembska, Anna; Juskowiak, Bernard

    2015-01-01

    In this work, we present a spectral characterization of pH-sensitive system, which combines the i-motif properties with the spatially sensitive fluorescence signal of pyrene molecules attached to hairpin ends. The excimer production (fluorescence max. ∼480 nm) by pyrene labels at the ends of the molecular beacon is driven by pH-dependent i-motif formation in the loop. To illustrate the performance and reversible work of our systems, we performed the experiments with repeatedly pH cycling between pH values of 7.5±0.3 and 6.5±0.3. The sensor gives analytical response in excimer-monomer switching mode in narrow pH range (1.5 pH units) and exhibits high pH resolution (0.1 pH unit). Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Nanomechanical DNA origami 'single-molecule beacons' directly imaged by atomic force microscopy

    Science.gov (United States)

    Kuzuya, Akinori; Sakai, Yusuke; Yamazaki, Takahiro; Xu, Yan; Komiyama, Makoto

    2011-01-01

    DNA origami involves the folding of long single-stranded DNA into designed structures with the aid of short staple strands; such structures may enable the development of useful nanomechanical DNA devices. Here we develop versatile sensing systems for a variety of chemical and biological targets at molecular resolution. We have designed functional nanomechanical DNA origami devices that can be used as 'single-molecule beacons', and function as pinching devices. Using 'DNA origami pliers' and 'DNA origami forceps', which consist of two levers ~170 nm long connected at a fulcrum, various single-molecule inorganic and organic targets ranging from metal ions to proteins can be visually detected using atomic force microscopy by a shape transition of the origami devices. Any detection mechanism suitable for the target of interest, pinching, zipping or unzipping, can be chosen and used orthogonally with differently shaped origami devices in the same mixture using a single platform. PMID:21863016

  20. Detection of DNA damage based on metal-mediated molecular beacon and DNA strands displacement reaction

    Science.gov (United States)

    Xiong, Yanxiang; Wei, Min; Wei, Wei; Yin, Lihong; Pu, Yuepu; Liu, Songqin

    2014-01-01

    DNA hairpin structure probes are usually designed by forming intra-molecular duplex based on Watson-Crick hydrogen bonds. In this paper, a molecular beacon based on silver ions-mediated cytosine-Ag+-cytosine base pairs was used to detect DNA. The inherent characteristic of the metal ligation facilitated the design of functional probe and the adjustment of its binding strength compared to traditional DNA hairpin structure probes, which make it be used to detect DNA in a simple, rapid and easy way with the help of DNA strands displacement reaction. The method was sensitive and also possesses the good specificity to differentiate the single base mismatched DNA from the complementary DNA. It was also successfully applied to study the damage effect of classic genotoxicity chemicals such as styrene oxide and sodium arsenite on DNA, which was significant in food science, environmental science and pharmaceutical science.

  1. Considerations for community-based mHealth initiatives: insights from three Beacon Communities.

    Science.gov (United States)

    Abebe, Nebeyou A; Capozza, Korey L; Des Jardins, Terrisca R; Kulick, David A; Rein, Alison L; Schachter, Abigail A; Turske, Scott A

    2013-10-15

    Mobile health (mHealth) is gaining widespread attention for its potential to engage patients in their health and health care in their daily lives. Emerging evidence suggests that mHealth interventions can be used effectively to support behavior change, but numerous challenges remain when implementing these programs at the community level. This paper provides an overview of considerations when implementing community-based mHealth initiatives, based on the experiences of three Beacon Communities across the United States that have launched text messaging (short message service, SMS) pilot programs aimed at diabetes risk reduction and disease management. The paper addresses lessons learned and suggests strategies to overcome challenges related to developing text message content, conducting marketing and outreach, enrolling participants, engaging providers, evaluating program effectiveness, and sustaining and scaling the programs.

  2. Improved analysis of plasmasphere motion using the VLA radio interferometer

    Directory of Open Access Journals (Sweden)

    G. W. Hoogeveen

    1997-02-01

    Full Text Available Observations using the very large (VLA radio interferometer during the past five years have enabled the discovery of a new type of plasmasphere disturbance, the magnetic eastward-directed wave. Previous work indicated these disturbances were likely frozen to the geomagnetic field as determined from their azimuth distributions. This work provides a method to explain more accurately the azimuth distribution, thereby allowing the calculation of the disturbances' location in the plasmasphere independently of the measured velocity. The measurable velocity due to corotation is calculated and subtracted from the measured trace velocity. This difference, or deviation from corotation, is attributed to electrodynamic convection; the measurement of plasmaspheric convection may lead to the eventual monitoring of mid-latitude electric fields. Disturbances are seen convecting predominantly westward, with the fastest having angular velocities greater than the anticorotating VLA line of sight. The direction of convection and conditions of observations indicate that the disturbances are likely the same phenomenon seen by the Los Alamos satellite beacon array.

  3. Improved analysis of plasmasphere motion using the VLA radio interferometer

    Directory of Open Access Journals (Sweden)

    G. W. Hoogeveen

    Full Text Available Observations using the very large (VLA radio interferometer during the past five years have enabled the discovery of a new type of plasmasphere disturbance, the magnetic eastward-directed wave. Previous work indicated these disturbances were likely frozen to the geomagnetic field as determined from their azimuth distributions. This work provides a method to explain more accurately the azimuth distribution, thereby allowing the calculation of the disturbances' location in the plasmasphere independently of the measured velocity. The measurable velocity due to corotation is calculated and subtracted from the measured trace velocity. This difference, or deviation from corotation, is attributed to electrodynamic convection; the measurement of plasmaspheric convection may lead to the eventual monitoring of mid-latitude electric fields. Disturbances are seen convecting predominantly westward, with the fastest having angular velocities greater than the anticorotating VLA line of sight. The direction of convection and conditions of observations indicate that the disturbances are likely the same phenomenon seen by the Los Alamos satellite beacon array.

  4. Evaluation of a rectangular rapid flashing beacon system at the Belmont Ridge Road and W&OD Trail mid-block crosswalk.

    Science.gov (United States)

    2015-05-01

    On April 8, 2013, the Virginia Department of Transportation (VDOT) installed a Rectangular Rapid Flashing Beacon : (RRFB) system at Belmont Ridge Road in Loudoun County that included two units at the Washington and Old Dominion : (W&OD) Trail crossin...

  5. Detection of Candida species in pregnant Chinese women with a molecular beacon method.

    Science.gov (United States)

    Zhai, Yanhong; Liu, Jing; Zhou, Li; Ji, Tongzhen; Meng, Lingxin; Gao, Yang; Liu, Ran; Wang, Xiao; Li, Lin; Lu, Binghuai; Cao, Zheng

    2018-04-20

    Candida pathogens are commonly found in women and can cause vulvovaginal candidiasis (VVC), whose infection rate is further increased during pregnancy. We aimed to study the Candida prevalence and strain distribution in pregnant Chinese women with a molecular beacon assay. From March 2016 to February 2017, a total of 993 pregnant women attending routine antenatal visits at the Beijing Obstetrics and Gynecology Hospital were enrolled. For Candida detection and identification, a unique molecular beacon assay was presented and compared with a traditional phenotypic method. Antifungal susceptibility was tested with the following agents: 5-flucytosine, amphotericin B, fluconazole, itraconazole and voriconazole. The prevalence of Candida was found to be 21.8 % when using the molecular method and 15.0 % when using the phenotypic method. The distribution of the Candida spp. was listed in order of decreasing prevalence: Candida albicans (79.8 %), Candida glabrata (13.5 %), Candida parapsilosis (3.7 %), Candida krusei (2.2 %) and Candida tropicalis (1.1 %). We found that 90.7 % of the Candida detection results were consistent between the molecular and the phenotypic methods. In the cases where the sequencing analyses for the Candida isolates resulted in inconsistent identification, the molecular method showed higher sensitivity than the phenotypic method (96.0 vs 64.6 %). C. albicans, C. glabrata and C. parapsilosis were essentially susceptible to all five antifungal agents tested, whereas C. tropicalis and C. krusei were susceptible to voriconazole and amphotericin B. By exhibiting good sensitivity and specificity, the molecular assay may offer a fast and accurate Candida screening platform for pregnant women.

  6. Energy optimization for upstream data transfer in 802.15.4 beacon-enabled star formulation

    Science.gov (United States)

    Liu, Hua; Krishnamachari, Bhaskar

    2008-08-01

    Energy saving is one of the major concerns for low rate personal area networks. This paper models energy consumption for beacon-enabled time-slotted media accessing control cooperated with sleeping scheduling in a star network formulation for IEEE 802.15.4 standard. We investigate two different upstream (data transfer from devices to a network coordinator) strategies: a) tracking strategy: the devices wake up and check status (track the beacon) in each time slot; b) non-tracking strategy: nodes only wake-up upon data arriving and stay awake till data transmitted to the coordinator. We consider the tradeoff between energy cost and average data transmission delay for both strategies. Both scenarios are formulated as optimization problems and the optimal solutions are discussed. Our results show that different data arrival rate and system parameters (such as contention access period interval, upstream speed etc.) result in different strategies in terms of energy optimization with maximum delay constraints. Hence, according to different applications and system settings, different strategies might be chosen by each node to achieve energy optimization for both self-interested view and system view. We give the relation among the tunable parameters by formulas and plots to illustrate which strategy is better under corresponding parameters. There are two main points emphasized in our results with delay constraints: on one hand, when the system setting is fixed by coordinator, nodes in the network can intelligently change their strategies according to corresponding application data arrival rate; on the other hand, when the nodes' applications are known by the coordinator, the coordinator can tune the system parameters to achieve optimal system energy consumption.

  7. The importance of Radio Quiet Zone (RQZ) for radio astronomy

    Science.gov (United States)

    Umar, Roslan; Abidin, Zamri Zainal; Ibrahim, Zainol Abidin

    2013-05-01

    Most of radio observatories are located in isolated areas. Since radio sources from the universe is very weak, astronomer need to avoid radio frequency interference (RFI) from active spectrum users and radio noise produced by human made (telecommunication, mobile phone, microwave user and many more. There are many observatories around the world are surrounded by a Radio Quiet Zone (RQZ), which is it was set up using public or state laws. A Radio Quiet Zone normally consists of two areas: an exclusive area in which totally radio emissions are forbidden, with restrictions for residents and business developments, and a larger (radius up to 100 km above) coordination area where the power of radio transmission limits to threshold levels. Geographical Information System (GIS) can be used as a powerful tool in mapping large areas with varying RQZ profiles. In this paper, we report the initial testing of the usage of this system in order to identify the areas were suitable for Radio Quiet Zone. Among the important parameters used to develop the database for our GIS are population density, information on TV and telecommunication (mobile phones) transmitters, road networks (highway), and contour shielding. We will also use other information gathered from on-site RFI level measurements on selected 'best' areas generated by the GIS. The intention is to find the best site for the purpose of establishing first radio quiet zones for radio telescope in Malaysia.

  8. MO-FG-BRA-06: Electromagnetic Beacon Insertion in Lung Cancer Patients and Resultant Surrogacy Errors for Dynamic MLC Tumour Tracking

    Energy Technology Data Exchange (ETDEWEB)

    Hardcastle, N; Booth, J; Caillet, V; Haddad, C; Crasta, C [Royal North Shore Hospital, St. Leonards, NSW (Australia); O’Brien, R; Keall, P [University of Sydney, Sydney, NSW (Australia); Szymura, K [Royal North Shore Hospital, Sydney, NSW (Australia)

    2016-06-15

    Purpose: To assess endo-bronchial electromagnetic beacon insertion and to quantify the geometric accuracy of using beacons as a surrogate for tumour motion in real-time multileaf collimator (MLC) tracking of lung tumours. Methods: The LIGHT SABR trial is a world-first clinical trial in which the MLC leaves move with lung tumours in real time on a standard linear accelerator. Tracking is performed based on implanted electromagnetic beacons (CalypsoTM, Varian Medical Systems, USA) as a surrogate for tumour motion. Five patients have been treated and have each had three beacons implanted endo-bronchially under fluoroscopic guidance. The centre of mass (C.O.M) has been used to adapt the MLC in real-time. The geometric error in using the beacon C.O.M as a surrogate for tumour motion was measured by measuring the tumour and beacon C.O.M in all phases of the respiratory cycle of a 4DCT. The surrogacy error was defined as the difference in beacon and tumour C.O.M relative to the reference phase (maximum exhale). Results: All five patients have had three beacons successfully implanted with no migration between simulation and end of treatment. Beacon placement relative to tumour C.O.M varied from 14 to 74 mm and in one patient spanned two lobes. Surrogacy error was measured in each patient on the simulation 4DCT and ranged from 0 to 3 mm. Surrogacy error as measured on 4DCT was subject to artefacts in mid-ventilation phases. Surrogacy error was a function of breathing phase and was typically larger at maximum inhale. Conclusion: Beacon placement and thus surrogacy error is a major component of geometric uncertainty in MLC tracking of lung tumours. Surrogacy error must be measured on each patient and incorporated into margin calculation. Reduction of surrogacy error is limited by airway anatomy, however should be taken into consideration when performing beacon insertion and planning. This research is funded by Varian Medical Systems via a collaborative research agreement.

  9. MO-FG-BRA-06: Electromagnetic Beacon Insertion in Lung Cancer Patients and Resultant Surrogacy Errors for Dynamic MLC Tumour Tracking

    International Nuclear Information System (INIS)

    Hardcastle, N; Booth, J; Caillet, V; Haddad, C; Crasta, C; O’Brien, R; Keall, P; Szymura, K

    2016-01-01

    Purpose: To assess endo-bronchial electromagnetic beacon insertion and to quantify the geometric accuracy of using beacons as a surrogate for tumour motion in real-time multileaf collimator (MLC) tracking of lung tumours. Methods: The LIGHT SABR trial is a world-first clinical trial in which the MLC leaves move with lung tumours in real time on a standard linear accelerator. Tracking is performed based on implanted electromagnetic beacons (CalypsoTM, Varian Medical Systems, USA) as a surrogate for tumour motion. Five patients have been treated and have each had three beacons implanted endo-bronchially under fluoroscopic guidance. The centre of mass (C.O.M) has been used to adapt the MLC in real-time. The geometric error in using the beacon C.O.M as a surrogate for tumour motion was measured by measuring the tumour and beacon C.O.M in all phases of the respiratory cycle of a 4DCT. The surrogacy error was defined as the difference in beacon and tumour C.O.M relative to the reference phase (maximum exhale). Results: All five patients have had three beacons successfully implanted with no migration between simulation and end of treatment. Beacon placement relative to tumour C.O.M varied from 14 to 74 mm and in one patient spanned two lobes. Surrogacy error was measured in each patient on the simulation 4DCT and ranged from 0 to 3 mm. Surrogacy error as measured on 4DCT was subject to artefacts in mid-ventilation phases. Surrogacy error was a function of breathing phase and was typically larger at maximum inhale. Conclusion: Beacon placement and thus surrogacy error is a major component of geometric uncertainty in MLC tracking of lung tumours. Surrogacy error must be measured on each patient and incorporated into margin calculation. Reduction of surrogacy error is limited by airway anatomy, however should be taken into consideration when performing beacon insertion and planning. This research is funded by Varian Medical Systems via a collaborative research agreement.

  10. The New Horizons Bistatic Radio Science Experiment to Measure Pluto's Surface Properties

    Science.gov (United States)

    Linscott, I.; Hinson, D. P.; Tyler, G. L.; Vincent, M.

    2014-12-01

    The New Horizons (NH) payload includes a Radio Science Experiment (REX) for principally occultation and radiometric measurement of Pluto and Charon during the flyby in July 2015. The REX subsystem is contained, together with the NH X-Band radio, in the Integrated Electronics Module (IEM) in the New Horizons spacecraft. REX samples and records in two polarizations both total RF power in a 4.5 MHz bandwidth, and radio signal waveforms in a narrow, 1.25 kHz band. During the encounter, and at closest approach to Pluto, the spacecraft's high gain antenna (HGA) will scan Pluto's equatorial latitudes, intercepting the specular zone, a region near Pluto's limb that geometrically favors reflection from the earth's direction. At the same time, a powerful 80 kW uplink beacon will have been transmitted from earth by the DSN to arrive at Pluto during spacecraft closest approach. Reflection from the specular zone is expected to be sufficiently strong to observe the bistatic uplink in the REX narrowband record. Measurements in both polarizations will then be combined to yield surface reflectivity, roughness and limits on the dielectric constant in the specular zone.

  11. Introduction to international radio regulations

    Energy Technology Data Exchange (ETDEWEB)

    Radicella, S M [Abdus Salam International Centre for Theoretical Physics, Trieste (Italy)

    2003-12-15

    These lecture notes contain an overview of basic problems of the International Radio Regulations. Access to the existing information infrastructure, and to that of the future Information Society, depends critically on radio, especially in poor, remote and sparsely populated regions with under-developed telecommunication infrastructure. How the spectrum of radio frequencies is regulated has profound impact on the society, its security, prosperity, and culture. The radio regulations represent a very important framework for an adequate use of radio and should be known by all of those working in the field.

  12. Introduction to international radio regulations

    International Nuclear Information System (INIS)

    Radicella, S.M.

    2003-01-01

    These lecture notes contain an overview of basic problems of the International Radio Regulations. Access to the existing information infrastructure, and to that of the future Information Society, depends critically on radio, especially in poor, remote and sparsely populated regions with under-developed telecommunication infrastructure. How the spectrum of radio frequencies is regulated has profound impact on the society, its security, prosperity, and culture. The radio regulations represent a very important framework for an adequate use of radio and should be known by all of those working in the field

  13. Radio-capacity of ecosystems

    International Nuclear Information System (INIS)

    Kultakhmedov, Yu.; Kultakhmedova-Vyshnyakova, V.

    1997-01-01

    This paper consider a universal approach to ecosystems of different types, based on representation of their radio-capacity. The concept of ecosystem includes reproduction of components (bio-productivity) and conditions such as maintaining of environment quality. Radio-capacity in the case of radionuclide pollution appears in accumulation and redistribution of radionuclides in the ecosystem. As a result the radionuclides are redistributed and buried in soil or lake bottom sediments. Estimation models for the radio-capacity of water and terrestrial ecosystems are represented. The calculations of the radio-capacity factor of water ecosystems are performed, and the high radio-capacity of a freshwater reservoir (F=0.6-0.8) and extremely high radio-capacity of a reservoir cascade (F c =0.99) is shown material from the Dnieper's cascade reservoirs. The methods of radio-capacity estimation of agroecosystems, wood and marine ecosystems are developed. (authors)

  14. The Concept of 'Radio Music'

    DEFF Research Database (Denmark)

    Fjeldsøe, Michael

    2016-01-01

    , educational and didactic effort which would enlighten all of society. For a while it seemed that radio music was considered a genre of its own. To fulfil its function, radio music had to consider technical limitations as well as the educational level and listening modes of the new mass audience. Public radio......, as discussed by Kurt Weill and Paul Hindemith, was at first greeted with great expectations, but soon a more realistic attitude prevailed. Weill, himself a radio critic as well, composed Der Lindberghflug (1929) as a piece of ‘radio music theatre’, but then changed some of its features in order to turn...... it into a didactical play for amateurs, a so-called Lehrstück. The article will present the concept of ‘radio music’ developed within German Neue Sachlichkeit and discuss the relevance of such a concept for current research in the field of radio and music....

  15. Tools of radio astronomy

    CERN Document Server

    Wilson, Thomas L; Hüttemeister, Susanne

    2009-01-01

    The recent years have seen breathtaking progress in technology, especially in the receiver and digital technologies relevant for radio astronomy, which has at the same time advanced to shorter wavelengths. This is the updated and completely revised 5th edition of the most used introductory text in radio astronomy. It presents a unified treatment of the entire field from centimeter to sub-millimeter wavelengths. Topics covered include instruments, sensitivity considerations, observational methods and interpretations of the data recorded with both single dishes and interferometers. This text is useful to both students and experienced practicing astronomers. Besides making major updates and additions throughout the book, the authors have re-organized a number of chapters to more clearly separate basic theory from rapidly evolving practical aspects. Further, problem sets have been added at the end of each chapter.

  16. Radio telescope control

    CERN Document Server

    Schraml, J

    1972-01-01

    An on-line computer control process developed for the 100-m radio telescope of the Max-Planck-Institut fur Radioastronomie in Bonn is described. The instrument is the largest fully steerable antenna in the world. Its operation started on May 31st 1972. It is controlled by a Ferranti Argus 500 on-line computer. The first part of the paper deals with the process itself, the radio telescope and its operation, and the demands resulting for the control program. The second part briefly describes the computer and its hardware. The final part introduces the architecture of the executive program in general, which has been tailored to meet the demands of the process and the hardware. The communication between the observer and the system, the format of data on magnetic tape and an on-line reduction of position measurements are considered. (0 refs).

  17. Die radio in Afrika

    Directory of Open Access Journals (Sweden)

    S. de Villiers

    1966-03-01

    Full Text Available Omvang van radio-uitsendings in en na Afrika. — Redes vir die versnelde tempo van uitbreiding. — Radio as die geskikste massa-kommunikasiemiddel vir Afrika. — Faktore wat die verspreiding bemoeilik. — Skouspelagtige toename in luistertalle.Toe Plinius, wat in die jaar 79 oorlede is, in sy „Historia Naturalis” verklaar het dat daar altyd iets nuuts uit Afrika afkomstig is, kon hy nouliks voorsien het dat die „iets" negentien eeue later in die lug sou setel wat hierdie reuse-vasteland oorspan — ’n Babelse spraakverwarring en ’n ongekende, verbete woorde-oorlog in die etergolwe, onder meer daarop bereken om die harte en hoofde van derduisendes te verower.

  18. An Interfacing System for Radiation Surveillance Using a Radio Communication Network

    International Nuclear Information System (INIS)

    Arunsiri, T.; Punnachaiya, S.; Pattarasumun, A.

    1998-01-01

    The development of an interfacing system for environmental radiation surveillance using radio communication network is aimed to improve a way by which environmental radiation measurement is transmitted and reported from the regional area monitoring station network. This also includes an automatic warning of beacon status via the radio link network to the center of environmental radiation control when an abnormal radiation level is detected. The interfacing system was developed by simulating the EGAT radio link network, the NT 2612, and can be separated into two parts. The first part was for a mobile station which can manage the output data from the radiation measurement system in the standard form of RS-232, IEEE-488, BCD and analog signal. This was accomplished by modulating the signal in selected baud rates ranging from 150 to 9600 bps using an economical radio packet capable of identifying and recalling the station code number. The other part is the linking system between the output data and the microcomputer equipped with a software to manage and evaluate the data from 10 surveillance stations for convenient handing of data output, statistical analysis and transmitting warning signal. Data transmission was tested using a baud rate of 1200 bps and was found to contain no detectable error when digital signal was transmitted while analog signal transmission resulted in deviations of less than ± 0.003%. The development of this radio link system provides a future trend for the environmental radiation monitoring network for countries with nuclear power plants or neighboring countries needed to continuously monitor for any abnormal radiation level in the environment. In case that the radiation surveillance system detects a high level of radiation, a warning signal will be transmitted and appropriate actions may be immediately exercised to control impacts of radiation on environment and living things according to international guidelines

  19. NOAA Weather Radio

    Science.gov (United States)

    cosas afectan la recepción de señas de la radio. Por ejemplo, las extensiones grandes de agua de sal receptor con una antena interior de calidad buena, o conectarlo a una antena externa. Generalmente los Programación Español Listado de estación Explicacion de SAME Coverage Station Listing County Listing

  20. Radio Frequency Interference Mitigation

    Science.gov (United States)

    An, T.; Chen, X.; Mohan, P.; Lao, B. Q.

    2017-09-01

    The observational facilities of radio astronomy keep constant upgrades and developments to achieve better capabilities including increasing the time of the data recording and frequency resolutions, and increasing the receiving and recording bandwidth. However in contrast, only a limited spectrum resource has been allocated to radio astronomy by the International Telecommunication Union, resulting in that the radio observational instrumentations are inevitably exposed to undesirable radio frequency interference (RFI) signals which originate mainly from the terrestrial human activity and are becoming stronger with time. RFIs degrade the quality of data and even lead to invalid data. The impact of RFIs on scientific outcome becomes more and more serious. In this article, the requirement for RFI mitigation is motivated, and the RFI characteristics, mitigation techniques, and strategies are reviewed. The mitigation strategies adopted at some representative observatories, telescopes, and arrays are also introduced. The advantages and shortcomings of the four classes of RFI mitigation strategies are discussed and presented, applicable at the connected causal stages: preventive, pre-detection, pre-correlation, and post-correlation. The proper identification and flagging of RFI is the key to the reduction of data loss and improvement in data quality, and is also the ultimate goal of developing RFI mitigation technique. This can be achieved through a strategy involving a combination of the discussed techniques in stages. The recent advances in the high speed digital signal processing and high performance computing allow for performing RFI excision of the large data volumes generated from large telescopes or arrays in both real time and offline modes, aiding the proposed strategy.

  1. AIDS radio triggers.

    Science.gov (United States)

    Elias, A M

    1991-07-01

    In April 1991, the Ethnic Communities' Council of NSW was granted funding under the Community AIDS Prevention and Education Program through the Department of Community Services and Health, to produce a series of 6x50 second AIDS radio triggers with a 10-second tag line for further information. The triggers are designed to disseminate culturally-sensitive information about HIV/AIDS in English, Italian, Greek, Spanish, Khmer, Turkish, Macedonian, Serbo-Croatian, Arabic, Cantonese, and Vietnamese, with the goal of increasing awareness and decreasing the degree of misinformation about HIV/AIDS among people of non-English-speaking backgrounds through radio and sound. The 6 triggers cover the denial that AIDS exists in the community, beliefs that words and feelings do not protect one from catching HIV, encouraging friends to be compassionate, compassion within the family, AIDS information for a young audience, and the provision of accurate and honest information on HIV/AIDS. The triggers are slated to be completed by the end of July 1991 and will be broadcast on all possible community, ethnic, and commercial radio networks across Australia. They will be available upon request in composite form with an information kit for use by health care professionals and community workers.

  2. Design of a K/Q-Band Beacon Receiver for the Alphasat Technology Demonstration Payload (TDP) #5 Experiment

    Science.gov (United States)

    Morse, Jacquelynne R.

    2014-01-01

    This paper describes the design and performance of a coherent KQ-band (2040 GHz) beacon receiver developed at NASA Glenn Research Center (GRC) that will be installed at the Politecnico di Milano (POLIMI) for use in the Alphasat Technology Demonstration Payload 5 (TDP5) beacon experiment. The goal of this experiment is to characterize rain fade attenuation at 40 GHz to improve the performance of existing statistical rain attenuation models in the Q-band. The ground terminal developed by NASA GRC utilizes an FFT-based frequency estimation receiver capable of characterizing total path attenuation effects due to gaseous absorption, clouds, rain, and scintillation. The receiver system has been characterized in the lab and demonstrates a system dynamic range performance of better than 58 dB at 1 Hz and better than 48 dB at 10 Hz rates.

  3. Hardware Implementation of A Non-RLL Soft-decoding Beacon-based Visible Light Communication Receiver

    OpenAIRE

    Nguyen, Duc-Phuc; Le, Dinh-Dung; Tran, Thi-Hong; Huynh, Huu-Thuan; Nakashima, Yasuhiko

    2018-01-01

    Visible light communication (VLC)-based beacon systems, which usually transmit identification (ID) information in small-size data frames are applied widely in indoor localization applications. There is one fact that flicker of LED light should be avoid in any VLC systems. Current flicker mitigation solutions based on run-length limited (RLL) codes suffer from reduced code rates, or are limited to hard-decoding forward error correction (FEC) decoders. Recently, soft-decoding techniques of RLL-...

  4. A case study of pediatric asthma alerts from the beacon community program in cincinnati: technology is just the first step.

    Science.gov (United States)

    Trudnak, Tara; Mansour, Mona; Mandel, Keith; Sauers, Hadley; Pandzik, Gerry; Donisi, Carl; Fairbrother, Gerry

    2014-01-01

    The Beacon Community in Cincinnati, Ohio was an innovative, community-wide initiative to use technology to transform care. One important feature was the development of regional alerts to notify practices when patients were hospitalized or seen in the emergency department. The purpose of this paper is to describe the way in which technology engages the improvement process, and to describe the early stages of learning how to use technology to enhance quality improvement. We interviewed key Beacon leaders as well as providers and office staff in selected practices. We also collected preliminary data from practices that reflected handling of alerts, including the number of asthma related alerts received and followed up. Regional alerts, supplied by the community-wide health information exchange, were a significant addition to the quality improvement effort in that they enabled practices to identify and follow up with additional children at risk. An important finding was the substantial effort at the practice level to integrate technology into ongoing patient care. Developing the technology for community wide alerts represented a significant endeavor in the Cincinnati Beacon Community. However, the technology was just the first step. Despite extra effort and time required on the part of individual practices, they reported that the value of having alerts was high. Hospital and ED visits represent some of the most costly aspects of care, and an efficient process for intervening with children using these costly services was seen as of significant value.

  5. Wind energy. From the garage workshop to a global market. 25 years scientific accompaniment; Windenergie - von der Garagen-Werkstatt zum Weltmarkt. 25 Jahre wissenschaftliche Begleitung

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Berthold; Stuebig, Cornelia [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany); Ponick, Bernd [Fraunhofer Institut fuer Windenergie und Energiesystemtechnik (IWES), Kassel (Germany); Hannover Univ. (Germany); Keller, Sarina [DLR Deutsches Zentrum fuer Luft- und Raumfahrt e.V., Koeln (Germany); Felder, Martin; Jachmann, Henning [Zentrum fuer Sonnenenergie- und Wasserstoff-Forschung Baden-Wuerttemberg (ZSW), Stuttgart (Germany)

    2015-04-15

    The plant technology for the use of wind energy on land is so sophisticated that the WEA can be operated as ''normal'' power plants to the grid. Of course, there are still potential for development, for example, in terms of improved reliability, or concerning the fledgling offshore use, always with an emphasis on the simultaneous reduction in costs. Although from the former garages workshops is little remaining, the production techniques are another major issue in terms of quality and costs. The cost of electricity from wind energy is taking account of external costs are already competitive with conventional power generation. To limit the costs of the energy transition one to expect from the wind energy as of the other technologies cost reduction. Various studies show that the wind energy supply in the balance is sufficient several times to provide the expected contribution to supply. [German] Die Anlagentechnologie fuer die Windenergienutzung an Land ist so ausgereift, dass die WEA als ''normale'' Kraftwerke am Netz betrieben werden koennen. Selbstverstaendlich bestehen weiterhin Entwicklungspotenziale, z. B. hinsichtlich verbesserter Zuverlaessigkeit oder bezueglich der noch jungen Offshore Nutzung, immer mit einem Augenmerk auf die gleichzeitige Kostenreduktion. Auch wenn von den ehemaligen Garagen Werkstaetten wenig uebrig geblieben ist, sind die Produktionstechniken ein weiteres wesentliches Thema bezueglich Qualitaet und Kosten. Die Kosteneffizienz der Stromerzeugung aus Windenergie ist unter Beruecksichtigung externer Kosten heute schon konkurrenzfaehig zur konventionellen Stromerzeugung. Zur Begrenzung der Kosten der Energiewende wird aber von der Windenergie wie von den anderen Technologien weiterhin eine Kostenreduktion erwartet. Diverse Studien zeigen, dass das Windenergieangebot in der Bilanz mehrfach ausreicht, um den erwarteten Beitrag zur Versorgung leisten zu koennen.

  6. Flexible Adaptation in Cognitive Radios

    CERN Document Server

    Li, Shujun

    2013-01-01

    This book provides an introduction to software-defined radio and cognitive radio, along with methodologies for applying knowledge representation, semantic web, logic reasoning and artificial intelligence to cognitive radio, enabling autonomous adaptation and flexible signaling. Readers from the wireless communications and software-defined radio communities will use this book as a reference to extend software-defined radio to cognitive radio, using the semantic technology described. Readers with a background in semantic web and artificial intelligence will find in this book the application of semantic web and artificial intelligence technologies to wireless communications. For readers in networks and network management, this book presents a new approach to enable interoperability, collaborative optimization and flexible adaptation of network components. Provides a comprehensive ontology covering the core concepts of wireless communications using a formal language; Presents the technical realization of using a ...

  7. Multi-Band (K- Q- and E-Band) Multi-Tone Millimeter-Wave Frequency Synthesizer for Radio Wave Propagation Studies

    Science.gov (United States)

    Simons, Rainee N.; Wintucky, Edwin G.

    2014-01-01

    This paper presents the design and test results of a multi-band multi-tone millimeter-wave frequency synthesizer, based on a solid-state frequency comb generator. The intended application of the synthesizer is in a space-borne transmitter for radio wave atmospheric studies at K-band (18 to 26.5 GHz), Q-band (37 to 42 GHz), and E-band (71 to 76 GHz). These studies would enable the design of robust multi-Gbps data rate space-to-ground satellite communication links. Lastly, the architecture for a compact multi-tone beacon transmitter, which includes a high frequency synthesizer, a polarizer, and a conical horn antenna, has been investigated for a notional CubeSat based space-to-ground radio wave propagation experiment.

  8. The properties of radio ellipticals

    International Nuclear Information System (INIS)

    Sparks, W.B.; Disney, M.J.; Rodgers, A.W.

    1984-01-01

    Optical and additional radio data are presented for the bright galaxies of the Disney and Wall survey (1977 Mon. Not. R. Astron. Soc. 179, 235). These data form the basis of a statistical comparison of the properties of radio elliptical galaxies to radio-quiet ellipticals. The correlations may be explained by the depth of the gravitational potential well in which the galaxy resides governing the circumstances under which an elliptical galaxy rids itself of internally produced gas. (author)

  9. Central radio sources

    International Nuclear Information System (INIS)

    Phinney, E.S.

    1985-01-01

    The compact radio sources in the nuclei of most active galaxies lie closer to their centers of activity than any other region accessible to observation, excepting only the broad emission line region. They provide uniquely strong evidence for bulk motion of matter at relativistic velocities, encouraging the belief that the activity originates in a gravitational potential well whose escape velocity is of the order of the speed of light. The observational facts are reviewed as well as several theoretical pictures of them. Those places where systematic observations could help to distinguish the true theoretical picture from the many competing forgeries are emphasized. 76 references

  10. A quantum dot-aptamer beacon using a DNA intercalating dye as the FRET reporter: application to label-free thrombin detection.

    Science.gov (United States)

    Chi, Chun-Wei; Lao, Yeh-Hsing; Li, Yi-Shan; Chen, Lin-Chi

    2011-03-15

    A new quantum dot (QD)-aptamer (apt) beacon that acts by folding-induced dissociation of a DNA intercalating dye, BOBO-3(B), is demonstrated with label-free thrombin detection. The beacon, denoted as QD-apt:B, is constructed by (1) coupling of a single-stranded thrombin aptamer to Qdot 565 via EDC/Sulfo-NHS chemistry and (2) staining the duplex regions of the aptamer on QD with excess BOBO-3 before thrombin binding. When mixing a thrombin sample with QD-apt:B, BOBO-3 is competed away from the beacon due to target-induced aptamer folding, which then causes a decrease in QD fluorescence resonance energy transfer (FRET)-mediated BOBO-3 emission and achieves thrombin quantitation. In this work, the effects of Mg(2+), coupling time, and aptamer type on the beacon's performances are investigated and discussed thoroughly with various methods, including transmission electron microscopy (TEM), dynamic light scattering (DLS), and two-color differential gel electrophoresis. Using the best aptamer beacon (HTQ37), we attain highly specific and wide-range detection (from nM to μM) of thrombin in buffer, and the beacon can sense nM-range thrombin in 15% diluted serum. Compared to the reported QD aptamer assays, our method is advantageous from the aspect of using a simple sensory unit design without losing the detection sensitivity. Therefore, we consider the QD-apt:B beacon a potential alternative to immuno-reagents and an effective tool to study nucleic acid folding on QD as well. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. Radio Frequency Anechoic Chamber Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Supports the design, manufacture, and test of antenna systems. The facility is also used as an electromagnetic compatibility/radio frequency interference...

  12. The Hartebeeshoek Radio Astronomy Observatory

    International Nuclear Information System (INIS)

    Nicolson, G.D.

    1986-01-01

    This article briefly discusses the questions, problems and study fields of the modern astronomer. Radioastronomy has made important contributions to the study of the evolution of stars and has given much information on the birth of stars while at the other extreme, studies of neutron stars and the radio emission from the remnants of supernova explosions have given further insight into the death of individual stars. Radio astronomical studies have learned astronomers much about the structure of the Milky way and some twenty years ago, in a search for new radio galaxies, quasars were discovered. Radioastronomy research in South Africa is carried out at the Hartebeesthoek Radio Astronomy Observatory

  13. Dramatugi Penyiar Radio

    Directory of Open Access Journals (Sweden)

    Hastika Yanti Nora

    2009-07-01

    Full Text Available Dramaturgy is the work of Erving Goffman. He wrote "Presentation of Self in Everyday Life" in '1959. Following the theatrical analogy, Goffman spoke of a front stage and back stage. The front stage is that part of the performance that generally functions in rather fixed and general ways to define the situation for those who observed the performance. The back stage is situation where facts suppressed in the front or various kinds of informal actions may appear. A back stage is usually adjacent to the front stage, but it also cut off from it. Everyone in this world have to run his role in their everyday life. It also a radio announcer. As an actor, they have to be a nice and friendy person when they perform to make air personality, that is  a good  impression, from their audience. But before their perform in the front stage, there so much to do to prepare in the backstage. The front and back stage is radio announcer dramaturgy.

  14. Space Weather Operation at KASI With Van Allen Probes Beacon Signals

    Science.gov (United States)

    Lee, Jongkil; Kim, Kyung-Chan; Giuseppe, Romeo; Ukhorskiy, Sasha; Sibeck, David; Kessel, Ramona; Mauk, Barry; Giles, Barbara; Gu, Bon-Jun; Lee, Hyesook; Park, Young-Deuk; Lee, Jaejin

    2018-02-01

    The Van Allen Probes (VAPs) are the only modern National Aeronautics and Space Administration (NASA) spacecraft broadcasting real-time data on the Earth's radiation belts for space weather operations. Since 2012, the Korea Astronomy and Space Science Institute (KASI) has contributed to the receipt of these data via a 7 m satellite-tracking antenna and used these beacon data for space weather operations. An approximately 15 min period is required from measurement to acquisition of Level-1 data. In this paper, we demonstrate the use of VAP data for monitoring space weather conditions at geostationary orbit (GEO) by highlighting the Saint Patrick's Day storm of 2015. During that storm, Probe-A observed a significant increase in the relativistic electron flux at 3 RE. Those electrons diffused outward resulting in a large increase of the electron flux >2 MeV at GEO, which potentially threatened satellite operations. Based on this study, we conclude that the combination of VAP data and National Oceanic and Atmospheric Administration-Geostationary Operational Environmental Satellite (NOAA-GOES) data can provide improved space environment information to geostationary satellite operators. In addition, the findings obtained indicate that more data-receiving sites would be necessary and data connections improved if this or a similar system were to be used as an operational data service.

  15. The Inversion of Ionospheric/plasmaspheric Electron Density From GPS Beacon Observations

    Science.gov (United States)

    Zou, Y. H.; Xu, J. S.; Ma, S. Y.

    It is a space-time 4-D tomography to reconstruct ionospheric/ plasmaspheric elec- tron density, Ne, from ground-based GPS beacon measurements. The mathematical foundation of such inversion is studied in this paper and some simulation results of reconstruction for GPS network observation are presented. Assuming reasonably a power law dependence of NE on time with an index number of 1-3 during one ob- servational time of GPS (60-90min.), 4-D inversion in consideration is reduced to a 3-D cone-beam tomography with incomplete projections. To see clearly the effects of the incompleteness on the quality of reconstruction for 3-D condition, we deduced theoretically the formulae of 3-D parallel-beam tomography. After establishing the mathematical basis, we adopt linear temporal dependence of NE and voxel elemental functions to perform simulation of NE reconstruction with the help of IRI90 model. Reasonable time-dependent 3-D images of ionosphere/ plasmasphere electron density distributions are obtained when taking proper layout of the GPS network and allowing variable resolutions in vertical.

  16. A molecular beacon microarray based on a quantum dot label for detecting single nucleotide polymorphisms.

    Science.gov (United States)

    Guo, Qingsheng; Bai, Zhixiong; Liu, Yuqian; Sun, Qingjiang

    2016-03-15

    In this work, we report the application of streptavidin-coated quantum dot (strAV-QD) in molecular beacon (MB) microarray assays by using the strAV-QD to label the immobilized MB, avoiding target labeling and meanwhile obviating the use of amplification. The MBs are stem-loop structured oligodeoxynucleotides, modified with a thiol and a biotin at two terminals of the stem. With the strAV-QD labeling an "opened" MB rather than a "closed" MB via streptavidin-biotin reaction, a sensitive and specific detection of label-free target DNA sequence is demonstrated by the MB microarray, with a signal-to-background ratio of 8. The immobilized MBs can be perfectly regenerated, allowing the reuse of the microarray. The MB microarray also is able to detect single nucleotide polymorphisms, exhibiting genotype-dependent fluorescence signals. It is demonstrated that the MB microarray can perform as a 4-to-2 encoder, compressing the genotype information into two outputs. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Learning from Health Information Exchange Technical Architecture and Implementation in Seven Beacon Communities

    Science.gov (United States)

    McCarthy, Douglas B.; Propp, Karen; Cohen, Alexander; Sabharwal, Raj; Schachter, Abigail A.; Rein, Alison L.

    2014-01-01

    As health care providers adopt and make “meaningful use” of health information technology (health IT), communities and delivery systems must set up the infrastructure to facilitate health information exchange (HIE) between providers and numerous other stakeholders who have a role in supporting health and care. By facilitating better communication and coordination between providers, HIE has the potential to improve clinical decision-making and continuity of care, while reducing unnecessary use of services. When implemented as part of a broader strategy for health care delivery system and payment reform, HIE capability also can enable the use of analytic tools needed for population health management, patient engagement in care, and continuous learning and improvement. The diverse experiences of seven communities that participated in the three-year federal Beacon Community Program offer practical insight into factors influencing the technical architecture of exchange infrastructure and its role in supporting improved care, reduced cost, and a healthier population. The case studies also document challenges faced by the communities, such as significant time and resources required to harmonize variations in the interpretation of data standards. Findings indicate that their progress developing community-based HIE strategies, while driven by local needs and objectives, is also influenced by broader legal, policy, and market conditions. PMID:25848591

  18. The Keys to Governance and Stakeholder Engagement: The Southeast Michigan Beacon Community Case Study

    Science.gov (United States)

    Des Jardins, Terrisca R.

    2014-01-01

    Community-based health information exchanges (HIEs) and efforts to consolidate and house data are growing, given the advent of Accountable Care Organizations (ACOs) under the Affordable Care Act and other similar population health focused initiatives. The Southeast Michigan Beacon Community (SEMBC) can be looked to as one case study that offers lessons learned, insights on challenges faced and accompanying workarounds related to governance and stakeholder engagement. The SEMBC case study employs an established Data Warehouse Governance Framework to identify and explain the necessary governance and stakeholder engagement components, particularly as they relate to community-wide data sharing and data warehouses or repositories. Perhaps the biggest lesson learned through the SEMBC experience is that community-based work is hard. It requires a great deal of community leadership, collaboration and resources. SEMBC found that organizational structure and guiding principles needed to be continually revisited and nurtured in order to build the relationships and trust needed among stakeholder organizations. SEMBC also found that risks and risk mitigation tactics presented challenges and opportunities at the outset and through the duration of the three year pilot period. Other communities across the country embarking on similar efforts need to consider realistic expectations about community data sharing infrastructures and the accompanying and necessary governance and stakeholder engagement fundamentals. PMID:25848612

  19. Theranostic properties of a survivin-directed molecular beacon in human melanoma cells.

    Directory of Open Access Journals (Sweden)

    Sara Carpi

    Full Text Available Survivin is an inhibitor of apoptosis overexpressed in different types of tumors and undetectable in most terminally differentiated normal tissues. In the current study, we sought to evaluate the in vitro theranostic properties of a molecular beacon-oligodeoxynucleotide (MB that targets survivin mRNA. We used laser scanning confocal microscopy to study MB delivery in living cells and real-time PCR and western blot to assess selective survivin-targeting in human malignant melanoma cells. We further assess the pro-apoptotic effect of MB by measuring internucleosomal DNA fragmentation, dissipation of mitochondrial membrane potential (MMP and changes in nuclear morphology. Transfection of MB into A375 and 501 Mel cells generated high signal intensity from the cytoplasm, while no signal was detected in the extracellular environment and in survivin-negative cells (i.e., human melanocytes and monocytes. MB time dependently decreased survivin mRNA and protein expression in melanoma cells with the maximum effect reached at 72 h. Treatment of melanoma cells with MB induced apoptosis by significant changes in MMP, accumulation of histone-complexed DNA fragments in the cytoplasm and nuclear condensation. MB also enhanced the pro-apoptotic effect of standard chemotherapeutic drugs tested at clinically relevant concentrations. The MB tested in the current study conjugates the ability of imaging with the pharmacological silencing activity against survivin mRNA in human melanoma cells and may represent an innovative approach for cancer diagnosis and treatment.

  20. Modified beacon probe assisted dual signal amplification for visual detection of microRNA.

    Science.gov (United States)

    Sun, Xiuwei; Ying, Na; Ju, Chuanjing; Li, Zhongyi; Xu, Na; Qu, Guijuan; Liu, Wensen; Wan, Jiayu

    2018-04-21

    In a recent study, we reported a novel assay for the detection of microRNA-21 based on duplex-specific nuclease (DSN)-assisted isothermal cleavage and hybridization chain reaction (HCR) dual signal amplification. The Fam modified double-stranded DNA products were generated after the HCR, another biotin modified probe was digested by DSN and released from the magnetic beads after the addition of the target miRNA. The released sequence was then combined with HCR products to form a double-tagging dsDNA, which can be recognized by the lateral flow strips. In this study, we introduced a 2-OMethyl-RNA modified beacon probe (2-OMe-MB) to make some improvements based on the previous study. Firstly, the substitution of modified probe combined on magnetic beads avoids the fussy washing steps for the separation of un-reacted probes. Furthermore, the modification of 2-OMe on the stem of the probe avoided the unnecessary cleavage by DSN, which greatly reduce the background signal. Compared to the previous work, these improvements save us a lot of steps but possess the comparable sensitivity and selectivity. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Outage Probability Analysis in Power-Beacon Assisted Energy Harvesting Cognitive Relay Wireless Networks

    Directory of Open Access Journals (Sweden)

    Ngoc Phuc Le

    2017-01-01

    Full Text Available We study the performance of the secondary relay system in a power-beacon (PB assisted energy harvesting cognitive relay wireless network. In our system model, a secondary source node and a relay node first harvest energy from distributed PBs. Then, the source node transmits its data to the destination node with the help of the relay node. Also, fading coefficients of the links from the PBs to the source node and relay node are assumed independent but not necessarily identically distributed (i.n.i.d Nakagami-m random variables. We derive exact expressions for the power outage probability and the channel outage probability. Based on that, we analyze the total outage probability of the secondary relay system. Asymptotic analysis is also performed, which provides insights into the system behavior. Moreover, we evaluate impacts of the primary network on the performance of the secondary network with respect to the tolerant interference threshold at the primary receiver as well as the interference introduced by the primary transmitter at the secondary source and relay nodes. Simulation results are provided to validate the analysis.

  2. Recognition of dual targets by a molecular beacon-based sensor: subtyping of influenza A virus.

    Science.gov (United States)

    Lee, Chun-Ching; Liao, Yu-Chieh; Lai, Yu-Hsuan; Lee, Chang-Chun David; Chuang, Min-Chieh

    2015-01-01

    A molecular beacon (MB)-based sensor to offer a decisive answer in combination with information originated from dual-target inputs is designed. The system harnesses an assistant strand and thermodynamically favored designation of unpaired nucleotides (UNs) to process the binary targets in "AND-gate" format and report fluorescence in "off-on" mechanism via a formation of a DNA four-way junction (4WJ). By manipulating composition of the UNs, the dynamic fluorescence difference between the binary targets-coexisting circumstance and any other scenario was maximized. Characteristic equilibrium constant (K), change of entropy (ΔS), and association rate constant (k) between the association ("on") and dissociation ("off") states of the 4WJ were evaluated to understand unfolding behavior of MB in connection to its sensing capability. Favorable MB and UNs were furthermore designed toward analysis of genuine genetic sequences of hemagglutinin (HA) and neuraminidase (NA) in an influenza A H5N2 isolate. The MB-based sensor was demonstrated to yield a linear calibration range from 1.2 to 240 nM and detection limit of 120 pM. Furthermore, high-fidelity subtyping of influenza virus was implemented in a sample of unpurified amplicons. The strategy opens an alternative avenue of MB-based sensors for dual targets toward applications in clinical diagnosis.

  3. Learning from health information exchange technical architecture and implementation in seven beacon communities.

    Science.gov (United States)

    McCarthy, Douglas B; Propp, Karen; Cohen, Alexander; Sabharwal, Raj; Schachter, Abigail A; Rein, Alison L

    2014-01-01

    As health care providers adopt and make "meaningful use" of health information technology (health IT), communities and delivery systems must set up the infrastructure to facilitate health information exchange (HIE) between providers and numerous other stakeholders who have a role in supporting health and care. By facilitating better communication and coordination between providers, HIE has the potential to improve clinical decision-making and continuity of care, while reducing unnecessary use of services. When implemented as part of a broader strategy for health care delivery system and payment reform, HIE capability also can enable the use of analytic tools needed for population health management, patient engagement in care, and continuous learning and improvement. The diverse experiences of seven communities that participated in the three-year federal Beacon Community Program offer practical insight into factors influencing the technical architecture of exchange infrastructure and its role in supporting improved care, reduced cost, and a healthier population. The case studies also document challenges faced by the communities, such as significant time and resources required to harmonize variations in the interpretation of data standards. Findings indicate that their progress developing community-based HIE strategies, while driven by local needs and objectives, is also influenced by broader legal, policy, and market conditions.

  4. Quantum Dot-Fullerene Based Molecular Beacon Nanosensors for Rapid, Highly Sensitive Nucleic Acid Detection.

    Science.gov (United States)

    Liu, Ye; Kannegulla, Akash; Wu, Bo; Cheng, Li-Jing

    2018-05-15

    Spherical fullerene (C 60 ) can quench the fluorescence of a quantum dot (QD) through energy transfer and charge transfer processes, with the quenching efficiency regulated by the number of proximate C 60 on each QD. With the quenching property and its small size compared with other nanoparticle-based quenchers, it is advantageous to group a QD reporter and multiple C 60 -labeled oligonucleotide probes to construct a molecular beacon (MB) probe for sensitive, robust nucleic acid detection. We demonstrated a rapid, high-sensitivity DNA detection method using the nanosensors composed of QD-C 60 based MBs carried by magnetic nanoparticles (MNPs). The assay was accelerated by first dispersing the nanosensors in analytes for highly efficient DNA capture resulting from short-distance 3-dimensional diffusion of targets to the sensor surface and then concentrating the nanosensors to a substrate by magnetic force to amplify the fluorescence signal for target quantification. The enhanced mass transport enabled a rapid detection (< 10 min) with a small sample volume (1-10 µl). The high signal-to-noise ratio produced by the QD-C 60 pairs and magnetic concentration yielded a detection limit of 100 fM (~106 target DNA copies for a 10 µl analyte). The rapid, sensitive, label-free detection method will benefit the applications in point-of-care molecular diagnostic technologies.

  5. The keys to governance and stakeholder engagement: the southeast michigan beacon community case study.

    Science.gov (United States)

    Des Jardins, Terrisca R

    2014-01-01

    Community-based health information exchanges (HIEs) and efforts to consolidate and house data are growing, given the advent of Accountable Care Organizations (ACOs) under the Affordable Care Act and other similar population health focused initiatives. The Southeast Michigan Beacon Community (SEMBC) can be looked to as one case study that offers lessons learned, insights on challenges faced and accompanying workarounds related to governance and stakeholder engagement. The SEMBC case study employs an established Data Warehouse Governance Framework to identify and explain the necessary governance and stakeholder engagement components, particularly as they relate to community-wide data sharing and data warehouses or repositories. Perhaps the biggest lesson learned through the SEMBC experience is that community-based work is hard. It requires a great deal of community leadership, collaboration and resources. SEMBC found that organizational structure and guiding principles needed to be continually revisited and nurtured in order to build the relationships and trust needed among stakeholder organizations. SEMBC also found that risks and risk mitigation tactics presented challenges and opportunities at the outset and through the duration of the three year pilot period. Other communities across the country embarking on similar efforts need to consider realistic expectations about community data sharing infrastructures and the accompanying and necessary governance and stakeholder engagement fundamentals.

  6. VLC-beacon detection with an under-sampled ambient light sensor

    Science.gov (United States)

    Green, Jacob; Pérez-Olivas, Huetzin; Martínez-Díaz, Saúl; García-Márquez, Jorge; Domínguez-González, Carlos; Santiago-Montero, Raúl; Guan, Hongyu; Rozenblat, Marc; Topsu, Suat

    2017-08-01

    LEDs will replace in a near future the current worldwide lighting mainly due to their low production-cost and energy-saving assets. Visible light communications (VLC) will turn gradually the existing lighting network into a communication network. Nowadays VLC transceivers can be found in some commercial centres in Europe; some of them broadcast continuously an identification tag that contains its coordinate position. In such a case, the transceiver acts as a geolocation beacon. Nevertheless, mobile transceivers represent a challenge in the VLC communication chain, as smartphones have not integrated yet a VLC customized detection stage. In order to make current smartphones capable to detect VLC broadcasted signals, their Ambient Light Sensor (ALS) is adapted as a VLC detector. For this to be achieved, lighting transceivers need to adapt their modulation scheme. For instance, frequencies representing start bit, 1, and 0 logic values can be set to avoid flicker from illumination and to permit detecting the under-sampled signal. Decoding the signal requires a multiple steps real-time signal processing as shown here.

  7. Gold nanoparticle-based beacon to detect STAT5b mRNA expression in living cells: a case optimized by bioinformatics screen.

    Science.gov (United States)

    Deng, Dawei; Li, Yang; Xue, Jianpeng; Wang, Jie; Ai, Guanhua; Li, Xin; Gu, Yueqing

    2015-01-01

    Messenger RNA (mRNA), a single-strand ribonucleic acid with functional gene information is usually abnormally expressed in cancer cells and has become a promising biomarker for the study of tumor progress. Hairpin DNA-coated gold nanoparticle (hDAuNP) beacon containing a bare gold nanoparticle (AuNP) as fluorescence quencher and thiol-terminated fluorescently labeled stem-loop-stem oligonucleotide sequences attached by Au-S bond is currently a new nanoscale biodiagnostic platform capable of mRNA detection, in which the design of the loop region sequence is crucial for hybridizing with the target mRNA. Hence, in this study, to improve the sensitivity and selectivity of hDAuNP beacon simultaneously, the loop region of hairpin DNA was screened by bioinformatics strategy. Here, signal transducer and activator of transcription 5b (STAT5b) mRNA was selected and used as a practical example. The results from the combined characterizations using optical techniques, flow cytometry assay, and cell microscopic imaging showed that after optimization, the as-prepared hDAuNP beacon had higher selectivity and sensitivity for the detection of STAT5b mRNA in living cells, as compared with our previous beacon. Thus, the bioinformatics method may be a promising new strategy for assisting in the designing of the hDAuNP beacon, extending its application in the detection of mRNA expression and the resultant mRNA-based biological processes and disease pathogenesis.

  8. Tuning in to pavement radio

    NARCIS (Netherlands)

    Ellis, S.

    1989-01-01

    This article describes a phenomenon known all over Africa, for which there is no really satisfactory term in English but which is summed up in the French term 'radio trottoir', literally 'pavement radio'. It may be defined as the popular and unofficial discussion of current affairs in Africa,

  9. Wide Field Radio Transient Surveys

    Science.gov (United States)

    Bower, Geoffrey

    2011-04-01

    The time domain of the radio wavelength sky has been only sparsely explored. Nevertheless, serendipitous discovery and results from limited surveys indicate that there is much to be found on timescales from nanoseconds to years and at wavelengths from meters to millimeters. These observations have revealed unexpected phenomena such as rotating radio transients and coherent pulses from brown dwarfs. Additionally, archival studies have revealed an unknown class of radio transients without radio, optical, or high-energy hosts. The new generation of centimeter-wave radio telescopes such as the Allen Telescope Array (ATA) will exploit wide fields of view and flexible digital signal processing to systematically explore radio transient parameter space, as well as lay the scientific and technical foundation for the Square Kilometer Array. Known unknowns that will be the target of future transient surveys include orphan gamma-ray burst afterglows, radio supernovae, tidally-disrupted stars, flare stars, and magnetars. While probing the variable sky, these surveys will also provide unprecedented information on the static radio sky. I will present results from three large ATA surveys (the Fly's Eye survey, the ATA Twenty CM Survey (ATATS), and the Pi GHz Survey (PiGSS)) and several small ATA transient searches. Finally, I will discuss the landscape and opportunities for future instruments at centimeter wavelengths.

  10. CONSTRAINING RADIO EMISSION FROM MAGNETARS

    Energy Technology Data Exchange (ETDEWEB)

    Lazarus, P.; Kaspi, V. M.; Dib, R. [Department of Physics, Rutherford Physics Building, McGill University, 3600 University Street, Montreal, Quebec H3A 2T8 (Canada); Champion, D. J. [Max-Planck-Institut fuer Radioastronomie, Auf dem Huegel 69, 53121 Bonn (Germany); Hessels, J. W. T., E-mail: plazar@physics.mcgill.ca [Netherlands Institute for Radio Astronomy (ASTRON), Postbus 2, 7990 AA Dwingeloo (Netherlands)

    2012-01-10

    We report on radio observations of five magnetars and two magnetar candidates carried out at 1950 MHz with the Green Bank Telescope in 2006-2007. The data from these observations were searched for periodic emission and bright single pulses. Also, monitoring observations of magnetar 4U 0142+61 following its 2006 X-ray bursts were obtained. No radio emission was detected for any of our targets. The non-detections allow us to place luminosity upper limits of L{sub 1950} {approx}< 1.60 mJy kpc{sup 2} for periodic emission and L{sub 1950,single} {approx}< 7.6 Jy kpc{sup 2} for single pulse emission. These are the most stringent limits yet for the magnetars observed. The resulting luminosity upper limits together with previous results are discussed, as is the importance of further radio observations of radio-loud and radio-quiet magnetars.

  11. Radio observations of symbiotic stars

    Energy Technology Data Exchange (ETDEWEB)

    Wright, A E [Commonwealth Scientific and Industrial Research Organization, Epping (Australia). Div. of Radiophysics; Allen, D A

    1978-09-01

    A search for 2-cm continuum emission from 91 symbiotic stars has been undertaken using the Parkes radio telescope. Nine sources have been detected, four of which are reported for the first time. The radio spectral indices are mostly about + 0.6; these are interpreted in terms of mass loss. In two stars a portion of the radio spectrum has an index of zero, and for one of these stars (RX Puppis) this is plausibly a manifestation of the cessation of symbiotic activity that occurred about two decades ago. There is an extraordinarily good correlation between the detectability at 2cm and the presence of circumstellar dust, but not between the radio and optical domains. The importance of continued radio monitoring of HM Sagittae over the next few years is stressed.

  12. Radio opaque gloves

    International Nuclear Information System (INIS)

    Whittaker, A.V.; Whittaker, R.E. Jr.; Goldstrom, R.A.; Shipko, F.J.

    1975-01-01

    Radiation shielding garments and accessories, such as radio-opaque gloves for surgeons, shielding against the harmful x-ray radiation in a fluoroscopic zone, are advantageously different from garments for shielding from other medical uses of x-rays. Such garments are provided with zones of differing opacity, whereby desired sensitivity and ''feel'' through the glove material is retained. One feature is the provision of an ''opacity gradient'' across the glove cross section with opacity being relatively low at the fingertip area (lesser shield-thickness), but relatively high at the less nonprehensile hand zones, such as the palm. Glove fabrication techniques for achieving such an opacity gradient are described. (U.S.)

  13. MUSIC RADIO-JOURNALISM

    Directory of Open Access Journals (Sweden)

    Dubovtceva Ludmila I.

    2014-04-01

    Full Text Available The article is based on years of practical experience, the author highlights the main radio genres in which music correspondent, music reviewer, music commentator, and music leading and a disc jockey work. Theoretical principles of their creative activities are analyzed in common journalistic genres, such as interview, reportage, talk show, live broadcast, radiofilm, as well as specialized genres like concert on demand and music competition. Journalist’ speech is seen as a logical element, the incoming with music in art-structural relationships. However, it does not become the predominant sound layer and aims to harmonious correlation or local penetration into music opus. In addition, important links in music journalism are defined the auxiliary "offscreen" editor's job and keeping the original sound archive. The author cites a number of own work examples on the air.

  14. Radio-adaptive response

    International Nuclear Information System (INIS)

    Ikushima, T.

    1992-01-01

    Knowledge about cellular events in mammalian cells exposed to low doses of ionizing radiation is meager. Recent works showed that human lymphocytes become resistant to radiation-induced chromosomal damage after exposure to low doses of ionizing radiation. Experimental evidence for radio-adaptive response (RAR) in cultured mammalian cells was obtained. Exposure to very low doses of gamma-rays or tritium beta-rays make cells less susceptible to the induction of micronuclei and sister chromatid exchanges by subsequent higher doses. Many important characteristics of the novel response suggest that RAR is a stress response resulting in the enhanced repair of chromosomal DNA damage in cell under restricted conditions. Experiments are still in progress in order to elucidate the molecular basis for RAR processes. (author). 13 refs.; 2 figs., 1 tab

  15. Implementing Software Defined Radio

    CERN Document Server

    Grayver, Eugene

    2013-01-01

    Software Defined Radio makes wireless communications easier, more efficient, and more reliable. This book bridges the gap between academic research and practical implementation. When beginning a project, practicing engineers, technical managers, and graduate students can save countless hours by considering the concepts presented in these pages. The author covers the myriad options and trade-offs available when selecting an appropriate hardware architecture. As demonstrated here, the choice between hardware- and software-centric architecture can mean the difference between meeting an aggressive schedule and bogging down in endless design iterations. Because of the author’s experience overseeing dozens of failed and successful developments, he is able to present many real-life examples. Some of the key concepts covered are: Choosing the right architecture for the market – laboratory, military, or commercial Hardware platforms – FPGAs, GPPs, specialized and hybrid devices Standardization efforts to ens...

  16. Radio-adaptive response

    International Nuclear Information System (INIS)

    Ikushima, Takaji

    1991-01-01

    An adaptive response to radiation stress was found in cultured Chinese hamster V79 cells, as a suppressed induction of micronuclei (MNs) and sister chromatid exchanges (SCEs) in the cells conditioned by very low doses. The important characteristics of the novel chromosomal response, called radio-adaptive response (RAR), that have newly emerged in this study are: 1) Low doses of beta-rays from tritiated water (HTO) as well as tritiated thymidine can cause the RAR. 2) Thermal neutrons, a high LET radiation, can not act as tritium beta-rays or gamma-rays. 3) The RAR expression is suppressed by an inhibition of protein synthesis. 4) Several proteins are newly synthesized concurrently with the RAR expression after adapting doses, viewed by two-dimensional electrophoresis of cellular proteins. These results suggest that the RAR is an adaptive chromosomal DNA repair induced by very low doses of low LET radiations under restricted conditions, accompanying the inducible specific gene expression. (author)

  17. A turbulent radio jet

    International Nuclear Information System (INIS)

    Kahn, F.D.

    1983-01-01

    A relativistic plasma flow can explain many of the observations on the one-sided jets, which are associated with radio sources that show superluminal motions in their cores. The pressure from the ambient medium will communicate across the jet in a relatively short distance, typically 30 kpc. The friction between the jet and the external medium then makes the flow go turbulent. As a result the jet dissipates energy and will be brought to rest within a few hundred kpc, if it does not strike an obstacle before. The mean flow in the jet is strongly sheared and stretches the lines of force of any magnetic field frozen into the plasma. The dominant field direction, as seen from the rest frame of the plasma, is therefore parallel to the length of the jet. Polarization measurements have shown that this is in fact the case. (author)

  18. AGONIZAN RADIOS MINERAS

    Directory of Open Access Journals (Sweden)

    Raquel Salinas

    2015-01-01

    Full Text Available Se ofrece un amplio análisis sobre la industria electoral, recordando que un candidato a presidente es "un producto para la venta". Se Desmenuzan las estrategias utilizadas en el plebiscito chileno,las elecciones norteamericanas con el NO a BUSH. El Mercadeo Social es una nueva metodología utilizada en proyectos de desarrollo a nivel de campo por ello se hace un esclarecimiento y clarifica el vínculo con la comunicación. Se agrega temas como: Los modelos de recepción de mensajes cuyos marcos conceptuales y metodologías aún no se han adaptado al potencial de esta línea de trabajo.Se analiza la agonía de las radios mineras en Bolivia en la que 42 años de historia y heroísmo se desmoronan.

  19. Radio-isotopic tracers

    International Nuclear Information System (INIS)

    Wolfangel, R.G.

    1976-01-01

    The invention concerns the dispersions that may be used for preparing radio-isotopic tracers, technetium labelled dispersions, processes for preparing these dispersions and their use as tracers. Technetium 99m sulphur colloids are utilized as scintillation tracers to give a picture of the reticulo-endothelial system, particularly the liver and spleen. A dispersion is provided which only requires the addition of a radioactive nuclide to form a radioactively labelled dispersion that can be injected as a tracer. It is formed of a colloid of tin sulphur dispersed in an aqueous buffer solution. Such a reagent has the advantage of being safe and reliable and is easier to use. The colloid can be prepared more quickly since additions of several different reagents are avoided. There is no need to heat up and no sulphuretted hydrogen, which is a toxic gas, is used [fr

  20. Radio frequency picosecond phototube

    International Nuclear Information System (INIS)

    Margaryan, A.; Carlini, R.; Ent, R.; Grigoryan, N.; Gyunashyan, K.; Hashimoto, O.; Hovater, K.; Ispiryan, M.; Knyazyan, S.; Kross, B.; Majewski, S.; Marikyan, G.; Mkrtchyan, M.; Parlakyan, L.; Popov, V.; Tang, L.; Vardanyan, H.; Yan, C.; Zhamkochyan, S.; Zorn, C.

    2006-01-01

    We propose a photon detector for recording low-level and ultra-fast optical signals, based on radio frequency (RF) analysis of low-energy photoelectrons (PEs). By using currently developed 500 MHz RF deflector, it is possible to scan circularly and detect single PEs, amplified in multi-channel plates (MCPs). The operation of the tube is investigated by means of thermionic electron source. It is demonstrated that the signals generated in the MCP can be processed event by event; by using available nanosecond electronics and that time resolution better than 20 ps can be achieved. Timing characteristics of the Cherenkov detector with RF phototube in a 'head-on' geometry is investigated by means of Monte Carlo simulation

  1. Radio frequency picosecond phototube

    Energy Technology Data Exchange (ETDEWEB)

    Margaryan, A. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia)]. E-mail: mat@mail.yerphi.am; Carlini, R. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Ent, R. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Grigoryan, N. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Gyunashyan, K. [Yerevan State University of Architecture and Construction, Yerevan (Armenia); Hashimoto, O. [Tohoku University, Sendai 98-77 (Japan); Hovater, K. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Ispiryan, M. [University of Houston, 4800 Calhoun Rd, Houston TX 77204 (United States); Knyazyan, S. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Kross, B. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Majewski, S. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Marikyan, G. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Mkrtchyan, M. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Parlakyan, L. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Popov, V. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Tang, L. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Vardanyan, H. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Yan, C. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States); Zhamkochyan, S. [Yerevan Physics Institute, 2 Alikhanian Brothers Street, Yerevan 375036 (Armenia); Zorn, C. [Thomas Jefferson National Accelerator Facility, Newport News VA 23606 (United States)

    2006-10-15

    We propose a photon detector for recording low-level and ultra-fast optical signals, based on radio frequency (RF) analysis of low-energy photoelectrons (PEs). By using currently developed 500 MHz RF deflector, it is possible to scan circularly and detect single PEs, amplified in multi-channel plates (MCPs). The operation of the tube is investigated by means of thermionic electron source. It is demonstrated that the signals generated in the MCP can be processed event by event; by using available nanosecond electronics and that time resolution better than 20 ps can be achieved. Timing characteristics of the Cherenkov detector with RF phototube in a 'head-on' geometry is investigated by means of Monte Carlo simulation.

  2. Radio propagation measurement and channel modelling

    CERN Document Server

    Salous, Sana

    2013-01-01

    While there are numerous books describing modern wireless communication systems that contain overviews of radio propagation and radio channel modelling, there are none that contain detailed information on the design, implementation and calibration of radio channel measurement equipment, the planning of experiments and the in depth analysis of measured data. The book would begin with an explanation of the fundamentals of radio wave propagation and progress through a series of topics, including the measurement of radio channel characteristics, radio channel sounders, measurement strategies

  3. Magnetospheric radio sounding

    International Nuclear Information System (INIS)

    Ondoh, Tadanori; Nakamura, Yoshikatsu; Koseki, Teruo; Watanabe, Sigeaki; Murakami, Toshimitsu

    1977-01-01

    Radio sounding of the plasmapause from a geostationary satellite has been investigated to observe time variations of the plasmapause structure and effects of the plasma convection. In the equatorial plane, the plasmapause is located, on the average, at 4 R sub(E) (R sub(E); Earth radius), and the plasma density drops outwards from 10 2 -10 3 /cm 3 to 1-10/cm 3 in the plasmapause width of about 600 km. Plasmagrams showing a relation between the virtual range and sounding frequencies are computed by ray tracing of LF-VLF waves transmitted from a geostationary satellite, using model distributions of the electron density in the vicinity of the plasmapause. The general features of the plasmagrams are similar to the topside ionograms. The plasmagram has no penetration frequency such as f 0 F 2 , but the virtual range of the plasmagram increases rapidly with frequency above 100 kHz, since the distance between a satellite and wave reflection point increases rapidly with increasing the electron density inside the plasmapause. The plasmapause sounder on a geostationary satellite has been designed by taking account of an average propagation distance of 2 x 2.6 R sub(E) between a satellite (6.6 R sub(E)) and the plasmapause (4.0 R sub(E)), background noise, range resolution, power consumption, and receiver S/N of 10 dB. The 13-bit Barker coded pulses of baud length of 0.5 msec should be transmitted in direction parallel to the orbital plane at frequencies for 10 kHz-2MHz in a pulse interval of 0.5 sec. The transmitter peak power of 70 watts and 700 watts are required respectively in geomagnetically quiet and disturbed (strong nonthermal continuum emissions) conditions for a 400 meter cylindrical dipole of 1.2 cm diameter on the geostationary satellite. This technique will open new area of radio sounding in the magnetosphere. (auth.)

  4. A Radio Astronomy Science Education Partnership - GAVRT and Radio JOVE

    Science.gov (United States)

    Higgins, C. A.; Thieman, J. R.; Bunnell, K.; Soholt, G.

    2009-12-01

    The planet Jupiter provides an excellent subject to educate, engage, and inspire students and teachers to learn science. The Goldstone Apple-Valley Radio Telescope (GAVRT) program (http://www.lewiscenter.org/gavrt) and The Radio JOVE project (http://radiojove.gsfc.nasa.gov) each have a long history of allowing students and teachers to interact with scientists and real radio telescopes. The upcoming Juno mission to Jupiter (2011 launch) allows both GAVRT and Radio JOVE to combine efforts and engage with the NASA Juno mission, thus increasing the excitement and learning potential for teachers, students, and the general public. Teachers can attend workshops for training to operate a 34-meter radio telescope and/or build their own simple radio telescope, both of which can be used directly in the classroom. We will overview some classroom activities and highlight some teacher-student experiences. In addition, we will update our efforts on greater Web-based control of the radio telescopes, as well as highlight our upcoming workshops to allow better access for teachers in different parts of the Country.

  5. South African Radio League Introduction to Amateur Radio: A study guide for the Radio Amateur Examination

    CSIR Research Space (South Africa)

    Burger, Chris

    2016-01-01

    Full Text Available ) .............................................................................. 15 1.12 The Radio Amateurs’ Examination .......................................................................... 15 1.13 Restrictions on the Use of an Amateur Radio Station .............................................. 16 Chapter 2: Operating... ............................................................................................. 116 14.1 Theory of Operation ............................................................................................... 116 14.2 Turns Ratio...

  6. Radio Astronomy Explorer /RAE/. I - Observations of terrestrial radio noise.

    Science.gov (United States)

    Herman, J. R.; Caruso, J. A.; Stone, R. G.

    1973-01-01

    Radio Astronomy Explorer (RAE) I data are analyzed to establish characteristics of HF terrestrial radio noise at an altitude of about 6000 km. Time and frequency variations in amplitude of the observed noise well above cosmic noise background are explained on the basis of temporal and spatial variations in ionospheric critical frequency coupled with those in noise source distributions. It is shown that terrestrial radio noise regularly breaks through the ionosphere and reaches RAE with magnitudes 15 dB and more above cosmic noise background, on frequencies above the F-layer critical frequency.

  7. Application of a molecular beacon based real-time isothermal amplification (MBRTIA) technology for simultaneous detection of Bacillus cereus and Staphylococcus aureus.

    Science.gov (United States)

    Mandappa, I M; Joglekar, Prasanna; Manonmani, H K

    2015-07-01

    A multiplex real-time isothermal amplification assay was developed using molecular beacons for the detection of Bacillus cereus and Staphylococcus aureus by targeting four important virulence genes. A correlation between targeting highly accessible DNA sequences and isothermal amplification based molecular beacon efficiency and sensitivity was demonstrated using phi(Φ)29 DNA polymerase at a constant isothermal temperature of 30 °C. It was very selective and consistently detected down to 10(1) copies of DNA. The specificity and sensitivity of this assay, when tested with pure culture were high, surpassing those of currently used PCR assays for the detection of these organisms. The molecular beacon based real-time isothermal amplification (MBRTIA) assay could be carried out entirely in 96 well plates or well strips, enabling a rapid and high-throughput detection of food borne pathogens.

  8. X rays from radio binaries

    International Nuclear Information System (INIS)

    Apparao, K.M.V.

    1977-01-01

    Reference is made to the radio binary systems CC Cas, AR Lac, β Per (Algol), β Lyr, b Per and Cyg X-1. It is stated that a thermal interpretation of the radiation from Algol requires a much larger x-ray flux than the observed value of 3.8 x 10 -11 erg/cm 2 /sec/keV in the 2 to 6 keV energy range. Observations of some non-thermal flares, together with the small size of the radio source in Algol, indicate that the radio emission is non-thermal in nature. The radio emission is interpreted as synchrotron radiation and it is suggested that the observed x-ray emission is due to inverse Compton scattering of the light of the primary star by the radio electrons. The x-ray emission from other radio binaries is also calculated using this model. The energy for the radio electrons can arise from annihilation of magnetic lines connecting the binary stars, twisted by the rotation of the stars. (U.K.)

  9. Gold nanoparticle-based beacon to detect STAT5b mRNA expression in living cells: a case optimized by bioinformatics screen

    Directory of Open Access Journals (Sweden)

    Deng D

    2015-04-01

    Full Text Available Dawei Deng,* Yang Li,* Jianpeng Xue, Jie Wang, Guanhua Ai, Xin Li, Yueqing GuDepartment of Biomedical Engineering, China Pharmaceutical University, Nanjing, People’s Republic of China*These authors contributed equally to this workAbstract: Messenger RNA (mRNA, a single-strand ribonucleic acid with functional gene information is usually abnormally expressed in cancer cells and has become a promising biomarker for the study of tumor progress. Hairpin DNA-coated gold nanoparticle (hDAuNP beacon containing a bare gold nanoparticle (AuNP as fluorescence quencher and thiol-terminated fluorescently labeled stem–loop–stem oligonucleotide sequences attached by Au–S bond is currently a new nanoscale biodiagnostic platform capable of mRNA detection, in which the design of the loop region sequence is crucial for hybridizing with the target mRNA. Hence, in this study, to improve the sensitivity and selectivity of hDAuNP beacon simultaneously, the loop region of hairpin DNA was screened by bioinformatics strategy. Here, signal transducer and activator of transcription 5b (STAT5b mRNA was selected and used as a practical example. The results from the combined characterizations using optical techniques, flow cytometry assay, and cell microscopic imaging showed that after optimization, the as-prepared hDAuNP beacon had higher selectivity and sensitivity for the detection of STAT5b mRNA in living cells, as compared with our previous beacon. Thus, the bioinformatics method may be a promising new strategy for assisting in the designing of the hDAuNP beacon, extending its application in the detection of mRNA expression and the resultant mRNA-based biological processes and disease pathogenesis.Keywords: molecular beacon, bioinformatics, gold nanoparticle, STAT5b mRNA, visual detection

  10. Theragnosis-based combined cancer therapy using doxorubicin-conjugated microRNA-221 molecular beacon.

    Science.gov (United States)

    Lee, Jonghwan; Choi, Kyung-Ju; Moon, Sung Ung; Kim, Soonhag

    2016-01-01

    Recently, microRNA (miRNA or miR) has emerged as a new cancer biomarker because of its high expression level in various cancer types and its role in the control of tumor suppressor genes. In cancer studies, molecular imaging and treatment based on target cancer markers have been combined to facilitate simultaneous cancer diagnosis and therapy. In this study, for combined therapy with diagnosis of cancer, we developed a doxorubicin-conjugated miR-221 molecular beacon (miR-221 DOXO MB) in a single platform composed of three different nucleotides: miR-221 binding sequence, black hole quencher 1 (BHQ1), and doxorubicin binding site. Imaging of endogenous miR-221 was achieved by specific hybridization between miR-221 and the miR-221 binding site in miR-221 DOXO MB. The presence of miR-221 triggered detachment of the quencher oligo and subsequent activation of a fluorescent signal of miR-221 DOXO MB. Simultaneous cancer therapy in C6 astrocytoma cells and nude mice was achieved by inhibition of miRNA-221 function that downregulates tumor suppressor genes. The detection of miR-221 expression and inhibition of miR-221 function by miR-221 DOXO MB provide the feasibility as a cancer theragnostic probe. Furthermore, a cytotoxic effect was induced by unloading of doxorubicin intercalated into miR-221 DOXO MB inside cells. Loss of miR-221 function and cytotoxicity induced by the miR-221 DOXO MB provides combined therapeutic efficacy against cancers. This method could be used as a new theragnostic probe with enhanced therapy to detect and inhibit many cancer-related miRNAs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Detection of Naja atra Cardiotoxin Using Adenosine-Based Molecular Beacon.

    Science.gov (United States)

    Shi, Yi-Jun; Chen, Ying-Jung; Hu, Wan-Ping; Chang, Long-Sen

    2017-01-07

    This study presents an adenosine (A)-based molecular beacon (MB) for selective detection of Naja atra cardiotoxin (CTX) that functions by utilizing the competitive binding between CTX and the poly(A) stem of MB to coralyne. The 5'- and 3'-end of MB were labeled with a reporter fluorophore and a non-fluorescent quencher, respectively. Coralyne induced formation of the stem-loop MB structure through A₂-coralyne-A₂ coordination, causing fluorescence signal turn-off due to fluorescence resonance energy transfer between the fluorophore and quencher. CTX3 could bind to coralyne. Moreover, CTX3 alone induced the folding of MB structure and quenching of MB fluorescence. Unlike that of snake venom α-neurotoxins, the fluorescence signal of coralyne-MB complexes produced a bell-shaped concentration-dependent curve in the presence of CTX3 and CTX isotoxins; a turn-on fluorescence signal was noted when CTX concentration was ≤80 nM, while a turn-off fluorescence signal was noted with a further increase in toxin concentrations. The fluorescence signal of coralyne-MB complexes yielded a bell-shaped curve in response to varying concentrations of N. atra crude venom but not those of Bungarus multicinctus and Protobothrops mucrosquamatus venoms. Moreover, N. nigricollis venom also functioned as N. atra venom to yield a bell-shaped concentration-dependent curve of MB fluorescence signal, again supporting that the hairpin-shaped MB could detect crude venoms containing CTXs. Taken together, our data validate that a platform composed of coralyne-induced stem-loop MB structure selectively detects CTXs.

  12. G-Quadruplex DNAzyme Molecular Beacon for Amplified Colorimetric Biosensing of Pseudostellaria heterophylla

    Directory of Open Access Journals (Sweden)

    Juan Hu

    2013-01-01

    Full Text Available With an internal transcribed spacer of 18 S, 5.8 S and 26 S nuclear ribosomal DNA (nrDNA ITS as DNA marker, we report a colorimetric approach for authentication of Pseudostellaria heterophylla (PH and its counterfeit species based on the differentiation of the nrDNA ITS sequence. The assay possesses an unlabelled G-quadruplex DNAzyme molecular beacon (MB probe, employing complementary sequence as biorecognition element and 1:1:1:1 split G-quadruplex halves as reporter. In the absence of target DNA (T-DNA, the probe can shape intermolecular G-quadruplex structures capable of binding hemin to form G-quadruplex-hemin DNAzyme and catalyze the oxidation of ABTS2− to blue-green ABTS•− by H2O2. In the presence of T-DNA, T-DNA can hybridize with the complementary sequence to form a duplex structure, hindering the formation of the G-quadruplex structure and resulting in the loss of the catalytic activity. Consequently, a UV-Vis absorption signal decrease is observed in the ABTS2−-H2O2 system. The “turn-off” assay allows the detection of T-DNA from 1.0 × 10−9 to 3.0 × 10−7 mol·L−1 (R2 = 0.9906, with a low detection limit of 3.1 × 10−10 mol·L−1. The present study provides a sensitive and selective method and may serve as a foundation of utilizing the DNAzyme MB sensor for identifying traditional Chinese medicines.

  13. The journey of primary care practices to meaningful use: a Colorado Beacon Consortium study.

    Science.gov (United States)

    Fernald, Douglas H; Wearner, Robyn; Dickinson, W Perry

    2013-01-01

    The Health Information Technology for Economic and Clinical Health Act of 2009 provides for incentive payments through Medicare and Medicaid for clinicians who implement electronic health records (EHRs) and use this technology meaningfully to improve patient care. There are few comprehensive descriptions of how primary care practices achieve the meaningful use of clinical data, including the formal stage 1 meaningful use requirements. Evaluation of the Colorado Beacon Consortium project included iterative qualitative analysis of practice narratives, provider and staff interviews, and separate focus groups with quality improvement (QI) advisors and staff from the regional health information exchange (HIE). Most practices described significant realignment of practice priorities and aims, which often required substantial education and training of physicians and staff. Re-engineering office processes, data collection protocols, EHRs, staff roles, and practice culture comprised the primary effort and commitment to attest to stage 1 meaningful use and subsequent meaningful use of clinical data. While realizing important benefits, practices bore a significant burden in learning the true capabilities of their EHRs with little effective support from vendors. Attestation was an important initial milestone in the process, but practices faced substantial ongoing work to use their data meaningfully for patient care and QI. Key resources were instrumental to these practices: local technical EHR expertise; collaborative learning mechanisms; and regular contact and support from QI advisors. Meeting the stage 1 requirements for incentives under Medicare and Medicaid meaningful use criteria is the first waypoint in a longer journey by primary care practices to the meaningful use of electronic data to continuously improve the care and health of their patients. The intensive re-engineering effort for stage 1 yielded practice changes consistent with larger practice aims and goals

  14. A Biofunctional Molecular Beacon for Detecting Single Base Mutations in Cancer Cells

    Directory of Open Access Journals (Sweden)

    Haiyan Dong

    2016-01-01

    Full Text Available The development of a convenient and sensitive biosensing system to detect specific DNA sequences is an important issue in the field of genetic disease therapy. As a classic DNA detection technique, molecular beacon (MB is often used in the biosensing system. However, it has intrinsic drawbacks, including high assay cost, complicated chemical modification, and operational complexity. In this study, we developed a simple and cost-effective label-free multifunctional MB (LMMB by integrating elements of polymerization primer, template, target recognition, and G-quadruplex into one entity to detect target DNA. The core technique was accomplished by introducing a G-hairpin that features fragments of both G-quadruplex and target DNA recognition in the G-hairpin stem. Hybridization between LMMB and target DNA triggered conformational change between the G-hairpin and the common C-hairpin, resulting in significant SYBR-green signal amplification. The hybridization continues to the isothermal circular strand-displacement polymerization and accumulation of the double-stranded fragments, causing the uninterrupted extension of the LMMB without a need of chemical modification and other assistant DNA sequences. The novel and programmable LMMB could detect target DNA with sensitivity at 250 pmol/l with a linear range from 2 to 100 nmol/l and the relative standard deviation of 7.98%. The LMMB could sense a single base mutation from the normal DNA, and polymerase chain reaction (PCR amplicons of the mutant-type cell line from the wild-type one. The total time required for preparation and assaying was only 25 minutes. Apparently, the LMMB shows great potential for detecting DNA and its mutations in biosamples, and therefore it opens up a new prospect for genetic disease therapy.

  15. Experimental Analysis of Sublimation Dynamics for Buried Glacier Ice in Beacon Valley, Antarctica

    Science.gov (United States)

    Ehrenfeucht, S.; Dennis, D. P.; Marchant, D. R.

    2017-12-01

    The age of the oldest known buried ice in Beacon Valley, McMurdo Dry Valleys (MDV) Antarctica is a topic of active debate due to its implications for the stability of the East Antarctic Ice Sheet. Published age estimates range from as young as 300 ka to as old as 8.1 Ma. In the upland MDV, ablation occurs predominantly via sublimation. The relict ice in question (ancient ice from Taylor Glacier) lies buried beneath a thin ( 30-70 cm) layer of sublimation till, which forms as a lag deposit as underlying debris-rich ice sublimes. As the ice sublimates, the debris held within the ice accumulates slowly on the surface, creating a porous boundary between the buried-ice surface and the atmosphere, which in turn influences gas exchange between the ice and the atmosphere. Additionally, englacial debris adds several salt species that are ultimately concentrated on the ice surface. It is well documented the rate of ice sublimation varies as a function of overlying till thickness. However, the rate-limiting dynamics under varying environmental conditions, including the threshold thicknesses at which sublimation is strongly retarded, are not yet defined. To better understand the relationships between sublimation rate, till thickness, and long-term surface evolution, we build on previous studies by Lamp and Marchant (2017) and evaluate the role of till thickness as a control on ice loss in an environmental chamber capable of replicating the extreme cold desert conditions observed in the MDV. Previous work has shown that this relationship exhibits exponential decay behavior, with sublimation rate significantly dampened under less than 10 cm of till. In our experiments we pay particular attention to the effect of the first several cm of till in order to quantify the dynamics that govern the transition from bare ice to debris-covered ice. We also examine this transition for various forms of glacier ice, including ice with various salt species.

  16. 75 FR 10439 - Cognitive Radio Technologies and Software Defined Radios

    Science.gov (United States)

    2010-03-08

    ... petition could not through the exercise of due diligence have learned of the facts in question prior to... to a wide variety of radio services, including safety-of-life services--the Commission holds the...

  17. radio frequency based radio frequency based water level monitor

    African Journals Online (AJOL)

    eobe

    ABSTRACT. This paper elucidates a radio frequency (RF) based transmission and reception system used to remotely monitor and .... range the wireless can cover but in this prototype, it ... power supply to the system, the sensed water level is.

  18. Introduction to solar radio astronomy and radio physics

    International Nuclear Information System (INIS)

    Krueger, A.

    1979-01-01

    A systematic summary is presented of the work done during the last thirty years in the field of solar radio astronomy from the standpoint of general solar physics. Instrumental aspects, observations and theory are covered. A brief introduction is given to the matter consisting of the history of solar radio astronomy and some fundamentals of astronomy and solar physics are outlined. Some topics of the instrumental background of solar radio astronomy and the main results of observations are presented. The elements of a theoretical interpretation of solar radio observations are reported and a synthesis of both observation and theory contributing to a general picture of solar and solar-terrestrial physics is outlined. (C.F./Auth)

  19. Potential effects of the introduction of the discrete address beacon system data link on air/ground information transfer problems

    Science.gov (United States)

    Grayson, R. L.

    1981-01-01

    This study of Aviation Safety Reporting System reports suggests that benefits should accure from implementation of discrete address beacon system data link. The phase enhanced terminal information system service is expected to provide better terminal information than present systems by improving currency and accuracy. In the exchange of air traffic control messages, discrete address insures that only the intended recipient receives and acts on a specific message. Visual displays and printer copy of messages should mitigate many of the reported problems associated with voice communications. The problems that remain unaffected include error in addressing the intended recipient and messages whose content is wrong but are otherwise correct as to format and reasonableness.

  20. Introduction to international radio regulations

    Energy Technology Data Exchange (ETDEWEB)

    Struzak, R

    2003-12-15

    These notes introduce the ITU Radio Regulations and related UN and WTO agreements that specify how terrestrial and satellite radio should be used in all countries over the planet. Access to the existing information infrastructure, and to that of the future Information Society, depends critically on these regulations. The paper also discusses few problems related to the use of the radio frequencies and satellite orbits. The notes are extracted from a book under preparation, in which these issues are discussed in more detail. (author)

  1. Introduction to international radio regulations

    International Nuclear Information System (INIS)

    Struzak, R.

    2003-01-01

    These notes introduce the ITU Radio Regulations and related UN and WTO agreements that specify how terrestrial and satellite radio should be used in all countries over the planet. Access to the existing information infrastructure, and to that of the future Information Society, depends critically on these regulations. The paper also discusses few problems related to the use of the radio frequencies and satellite orbits. The notes are extracted from a book under preparation, in which these issues are discussed in more detail. (author)

  2. Magnetogasdynamics of double radio sources

    International Nuclear Information System (INIS)

    Nepveu, M.

    1979-01-01

    The magnetogasdynamical behaviour of plasmoids moving through an ambient gas is investigated numerically with a two-dimensional code, based on the SHASTA scheme. The astrophysical importance of this study lies in the observed extended extragalactic radio sources. It is assumed that plasma clouds with cylinder symmetry are ejected from the nucleus of a galaxy. Their large-scale evolution in the intergalactic medium (IGM) is followed. The gas dynamics of an ejected cloud, the magnetogasdynamics of ejected clouds, the Christiansen-Pacholczyk-Scott picture for radio galaxies and the shear layers in double radio sources are studied. (Auth.)

  3. Shoestring Budget Radio Astronomy (Abstract)

    Science.gov (United States)

    Hoot, J. E.

    2017-12-01

    (Abstract only) The commercial exploitation of microwave frequencies for cellular, WiFi, Bluetooth, HDTV, and satellite digital media transmission has brought down the cost of the components required to build an effective radio telescope to the point where, for the cost of a good eyepiece, you can construct and operate a radio telescope. This paper sets forth a family of designs for 1421 MHz telescopes. It also proposes a method by which operators of such instruments can aggregate and archive data via the Internet. With 90 or so instruments it will be possible to survey the entire radio sky for transients with a 24 hour cadence.

  4. The excess radio background and fast radio transients

    International Nuclear Information System (INIS)

    Kehayias, John; Kephart, Thomas W.; Weiler, Thomas J.

    2015-01-01

    In the last few years ARCADE 2, combined with older experiments, has detected an additional radio background, measured as a temperature and ranging in frequency from 22 MHz to 10 GHz, not accounted for by known radio sources and the cosmic microwave background. One type of source which has not been considered in the radio background is that of fast transients (those with event times much less than the observing time). We present a simple estimate, and a more detailed calculation, for the contribution of radio transients to the diffuse background. As a timely example, we estimate the contribution from the recently-discovered fast radio bursts (FRBs). Although their contribution is likely 6 or 7 orders of magnitude too small (though there are large uncertainties in FRB parameters) to account for the ARCADE 2 excess, our development is general and so can be applied to any fast transient sources, discovered or yet to be discovered. We estimate parameter values necessary for transient sources to noticeably contribute to the radio background

  5. Radio frequency integrated circuit design for cognitive radio systems

    CERN Document Server

    Fahim, Amr

    2015-01-01

    This book fills a disconnect in the literature between Cognitive Radio systems and a detailed account of the circuit implementation and architectures required to implement such systems.  Throughout the book, requirements and constraints imposed by cognitive radio systems are emphasized when discussing the circuit implementation details.  In addition, this book details several novel concepts that advance state-of-the-art cognitive radio systems.  This is a valuable reference for anybody with background in analog and radio frequency (RF) integrated circuit design, needing to learn more about integrated circuits requirements and implementation for cognitive radio systems. ·         Describes in detail cognitive radio systems, as well as the circuit implementation and architectures required to implement them; ·         Serves as an excellent reference to state-of-the-art wideband transceiver design; ·         Emphasizes practical requirements and constraints imposed by cognitive radi...

  6. A radio and optical study of Molonglo radio sources

    Science.gov (United States)

    Ishwara-Chandra, C. H.; Saikia, D. J.; McCarthy, P. J.; van Breugel, W. J. M.

    2001-05-01

    We present multi-wavelength radio observations with the Very Large Array, and narrow- and broad-band optical observations with the 2.5-m telescope at the Las Campanas Observatory, of a well-defined sample of high-luminosity Fanaroff-Riley class II radio galaxies and quasars, selected from the Molonglo Reference Catalogue 1-Jy sample. These observations were carried out as part of a programme to investigate the effects of orientation and environment on some of the observed properties of these sources. We examine the dependence of the Liu-Pooley relationship, which shows that radio lobes with flatter radio spectra are less depolarized, on size, identification and redshift, and show that it is significantly stronger for smaller sources, with the strength of the relationship being similar for both radio galaxies and quasars. In addition to Doppler effects, there appear to be intrinsic differences between the lobes on opposite sides. We discuss the asymmetry in brightness and location of the hotspots, and present estimates of the ages and velocities from matched-resolution observations in the L and C bands. Narrow- and broad-band optical images of some of these sources were made to study their environments and correlate with the symmetry parameters. An extended emission-line region is seen in a quasar, and in four of the objects possible companion galaxies are seen close to the radio axis.

  7. Radio-adaptive response

    International Nuclear Information System (INIS)

    Ikushima, T.

    1992-01-01

    An adaptive response to radiation stress was found as a suppressed induction of chromosomal damage including micronuclei and sister chromatid exchanges in cultured Chinese hamster V79 cells pre-exposed to very low doses of ionizing radiations. The mechanism underlying this novel chromosomal response, called 'radio-adaptive response (RAR)' has been studied progressively. The following results were obtained in recent experiments. 1. Low doses of β-rays from tritiated water (HTO) as well as tritium-thymidine can cause RAR. 2. Thermal neutrons, a high LET radiation, can not act as tritium β-rays or γ-rays. 3. The RAR expression is suppressed not only by the treatment with an inhibitor of protein synthesis but also by RNA synthesis inhibition. 4. Several proteins are newly synthesized concurrently with the RAR expression after the adapting doses, viewed by two-dimensional electrophoresis of cellular proteins. These results suggests that the RAR might be a cellular stress response to a signal produced preferentially by very low doses of low LET radiation under restricted conditions, accompany the inducible specific gene expression. (author)

  8. Beamsteerable GNSS Radio Occultation ASIC

    Data.gov (United States)

    National Aeronautics and Space Administration — We will develop an integrated RF ASIC to enable high quality radio occultation (RO) weather observations using the Global Navigations System Satellite (GNSS)...

  9. Sea Turtle Radio Telemetry Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Radio transmitters attached to sea turtles captured in various fishing gear enabled us to track and measure surfacing time of each turtle. Determining location of...

  10. Zero-Power Radio Device.

    Energy Technology Data Exchange (ETDEWEB)

    Brocato, Robert W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2018-02-01

    This report describes an unpowered radio receiver capable of detecting and responding to weak signals transmit ted from comparatively long distances . This radio receiver offers key advantages over a short range zero - power radio receiver previously described in SAND2004 - 4610, A Zero - Power Radio Receiver . The device described here can be fabricated as an integrated circuit for use in portable wireless devices, as a wake - up circuit, or a s a stand - alone receiver operating in conjunction with identification decoders or other electroni cs. It builds on key sub - components developed at Sandia National Laboratories over many years. It uses surface acoustic wave (SAW) filter technology. It uses custom component design to enable the efficient use of small aperture antennas. This device uses a key component, the pyroelectric demodulator , covered by Sandia owned U.S. Patent 7397301, Pyroelectric Demodulating Detector [1] . This device is also described in Sandia owned U.S. Patent 97266446, Zero Power Receiver [2].

  11. On the evaluation of Web Radio

    OpenAIRE

    Field, A.N.; Hartel, Pieter H.

    2001-01-01

    We develop an evaluation method for Web radio, and perform it to see what we can be learnt about seven prominent Web radio sites. We also evaluate a commercial FM radio station for control purposes. We present a taxonomy of Web radio, and we give our observations and conclusions on this evaluation.

  12. Radio and line transmission 2

    CERN Document Server

    Roddy, Dermot

    2013-01-01

    Radio and Line Transmission, Volume 2 gives a detailed treatment of the subject as well as an introduction to additional advanced subject matter. Organized into 14 chapters, this book begins by explaining the radio wave propagation, signal frequencies, and bandwidth. Subsequent chapters describe the transmission lines and cables; the aerials; tuned and coupled circuits; bipolar transistor amplifiers; field-effect transistors and circuits; thermionic valve amplifiers; LC oscillators; the diode detectors and modulators; and the superheterodyne receiver. Other chapters explore noise and interfere

  13. Historic Radio Astronomy Working Group

    Science.gov (United States)

    2007-06-01

    This special issue of Astronomische Nachrichten contains the proceedings of a session of the Historic Radio Astronomy Working Group of the International Astronomical Union that took place during the 26th General Assembly of the IAU in Prague on 17th August 2006. In addition to the talks presented in Prague some contributions were solicited to give a more complete overview of `The Early History of European Radio Astronomy'.

  14. Radio astronomy on the moon

    International Nuclear Information System (INIS)

    Burns, J.O.; Asbell, J.

    1987-01-01

    The advantages and opportunities for radio astronomy on the moon during the early to mid 21st century are reviewed. In particular, it is argued that the lack of atmosphere, the extremely low seismic activity, the low RF background, and the natural cryogenic environment make the moon (particularly the far side and the poles) a nearly ideal locale for submillimeter/FIR to VLF (below 10 MHz) radio astronomy. 22 references

  15. RADIO NOISE ADVANCES SEXUAL MATURITY

    African Journals Online (AJOL)

    ansistf-lewis

    Mean age at first egg for the radio birds (143 d) was 13 d significantly earlier than controls, but body weight at ... the first 8 h of a 12-h photoperiod with radio noise, to leave only 4 h of light (4L:20D), supported rates of lay ... Age (AFE) and body weight at, and weight of, first egg were recorded for individual birds, and, after a.

  16. RADIO WITHOUT A LISTENER: "MAYAK"

    Directory of Open Access Journals (Sweden)

    Bysko Maxim V.

    2017-12-01

    Full Text Available The singularity of this article is that it is entirely based on a critical analysis of only one live musical radio program on the Mayak radio station and dedicated to the life and work of the famous British composer Andrew Lloyd Webber. In principle, the article can be considered a scientific review of the media product. Based on his analysis, the author comes to the paradoxical conclusion that the presence of a listener becomes unnecessary for modern broadcasting. This is stated by many principles of the conduct of the air, presented in the radio program, where all the information load is placed on the guest in the studio, where there is no preparatory work of the DJs, where their inability to navigate the genres of journalism violates communication norms and colloquial ethics, where an obvious deconstructive approach to the material offered for the listener. In addition, the phenomenon of being the DJs in the radio studio exclusively "for themselves" is emphasized by the sound design of the radio program, which runs counter to the logic of auditory perception (for example, the sequence of jingles, as well as the incompetent selection of musical material, which undoubtedly repels professional radio listeners-musicians.

  17. The radio properties of infrared-faint radio sources

    Science.gov (United States)

    Middelberg, E.; Norris, R. P.; Hales, C. A.; Seymour, N.; Johnston-Hollitt, M.; Huynh, M. T.; Lenc, E.; Mao, M. Y.

    2011-02-01

    Context. Infrared-faint radio sources (IFRS) are objects that have flux densities of several mJy at 1.4 GHz, but that are invisible at 3.6 μm when using sensitive Spitzer observations with μJy sensitivities. Their nature is unclear and difficult to investigate since they are only visible in the radio. Aims: High-resolution radio images and comprehensive spectral coverage can yield constraints on the emission mechanisms of IFRS and can give hints to similarities with known objects. Methods: We imaged a sample of 17 IFRS at 4.8 GHz and 8.6 GHz with the Australia Telescope Compact Array to determine the structures on arcsecond scales. We added radio data from other observing projects and from the literature to obtain broad-band radio spectra. Results: We find that the sources in our sample are either resolved out at the higher frequencies or are compact at resolutions of a few arcsec, which implies that they are smaller than a typical galaxy. The spectra of IFRS are remarkably steep, with a median spectral index of -1.4 and a prominent lack of spectral indices larger than -0.7. We also find that, given the IR non-detections, the ratio of 1.4 GHz flux density to 3.6 μm flux density is very high, and this puts them into the same regime as high-redshift radio galaxies. Conclusions: The evidence that IFRS are predominantly high-redshift sources driven by active galactic nuclei (AGN) is strong, even though not all IFRS may be caused by the same phenomenon. Compared to the rare and painstakingly collected high-redshift radio galaxies, IFRS appear to be much more abundant, but less luminous, AGN-driven galaxies at similar cosmological distances.

  18. Information Content in Radio Waves: Student Investigations in Radio Science

    Science.gov (United States)

    Jacobs, K.; Scaduto, T.

    2013-12-01

    We describe an inquiry-based instructional unit on information content in radio waves, created in the summer of 2013 as part of a MIT Haystack Observatory (Westford, MA) NSF Research Experiences for Teachers (RET) program. This topic is current and highly relevant, addressing science and technical aspects from radio astronomy, geodesy, and atmospheric research areas as well as Next Generation Science Standards (NGSS). Projects and activities range from simple classroom demonstrations and group investigations, to long term research projects incorporating data acquisition from both student-built instrumentation as well as online databases. Each of the core lessons is applied to one of the primary research centers at Haystack through an inquiry project that builds on previously developed units through the MIT Haystack RET program. In radio astronomy, students investigate the application of a simple and inexpensive software defined radio chip (RTL-SDR) for use in systems implementing a small and very small radio telescope (SRT and VSRT). Both of these systems allow students to explore fundamental principles of radio waves and interferometry as applied to radio astronomy. In ionospheric research, students track solar storms from the initial coronal mass ejection (using Solar Dynamics Observatory images) to the resulting variability in total electron density concentrations using data from the community standard Madrigal distributed database system maintained by MIT Haystack. Finally, students get to explore very long-baseline interferometry as it is used in geodetic studies by measuring crustal plate displacements over time. Alignment to NextGen standards is provided for each lesson and activity with emphasis on HS-PS4 'Waves and Their Applications in Technologies for Information Transfer'.

  19. Studying the influence of stem composition in pH-sensitive molecular beacons onto their sensing properties.

    Science.gov (United States)

    Dembska, Anna; Kierzek, Elzbieta; Juskowiak, Bernard

    2017-10-16

    Intracellular sensing using fluorescent molecular beacons is a potentially useful strategy for real-time, in vivo monitoring of important cellular events. This work is focused on evaluation of pyrene excimer signaling molecular beacons (MBs) for the monitoring of pH changes in vitro as well as inside living cells. The recognition element in our MB called pHSO (pH-sensitive oligonucleotide) is the loop enclosing cytosine-rich fragment that is able to form i-motif structure in a specific pH range. However, alteration of a sequence of the 6 base pairs containing stem of MB allowed the design of pHSO probes that exhibited different dynamic pH range and possessed slightly different transition midpoint between i-motif and open loop configuration. Moreover, this conformational transition was accompanied by spectral changes showing developed probes different pyrene excimer-monomer emission ratio triggered by pH changes. The potential of these MBs for intracellular pH sensing is demonstrated on the example of HeLa cells line. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Radio Frequency Interference Site Survey for Thai Radio Telescopes

    Science.gov (United States)

    Jaroenjittichai, P.; Punyawarin, S.; Singwong, D.; Somboonpon, P.; Prasert, N.; Bandudej, K.; Kempet, P.; Leckngam, A.; Poshyachinda, S.; Soonthornthum, B.; Kramer, B.

    2017-09-01

    Radio astronomical observations have increasingly been threaten by the march of today telecommunication and wireless technology. Performance of radio telescopes lies within the fact that astronomical sources are extremely weak. National Astronomy Research Institute of Thailand (NARIT) has initiated a 5-year project, known as the Radio Astronomy Network and Geodesy for Development (RANGD), which includes the establishment of 40-meter and 13-meter radio telescopes. Possible locations have been narrowed down to three candidates, situated in the Northern part of Thailand, where the atmosphere is sufficiently dry and suitable for 22 and 43 GHz observations. The Radio Frequency Interference (RFI) measurements were carried out with a DC spectrum analyzer and directional antennas at 1.5 meter above ground, from 20 MHz to 6 GHz with full azimuth coverage. The data from a 3-minute pointing were recorded for both horizontal and vertical polarizations, in maxhold and average modes. The results, for which we used to make preliminary site selection, show signals from typical broadcast and telecommunication services and aeronautics applications. The signal intensity varies accordingly to the presence of nearby population and topography of the region.

  1. SOX2 and OCT4 mRNA-Expressing Cells, Detected by Molecular Beacons, Localize to the Center of Neurospheres during Differentiation

    DEFF Research Database (Denmark)

    Ilieva, Mirolyuba; Dufva, Martin

    2013-01-01

    Neurospheres are used as in vitro assay to measure the properties of neural stem cells. To investigate the molecular and phenotypic heterogeneity of neurospheres, molecular beacons (MBs) targeted against the stem cell markers OCT4 and SOX2 were designed, and synthesized with a 2'-O-methyl RNA...

  2. Molecular Beacon Enables Combination of Highly Processive and Highly Sensitive Rolling Circle Amplification Readouts for Detection of DNA-Modifying Enzymes

    DEFF Research Database (Denmark)

    Kristoffersen, Emil Laust; Gonzales, Maria; Stougaard, Magnus

    2015-01-01

    is separated, giving rise to a fluorescent signal, measurable in pseudo real-time using a qPCR machine or in a fluorimeter. The RCA products in complex with the molecular beacon can subsequently be moved to microscopic slides and analyzed in a fluorescence microscope. We describe the proof of the principle...

  3. IA-Regional-Radio - Social Network for Radio Recommendation

    Science.gov (United States)

    Dziczkowski, Grzegorz; Bougueroua, Lamine; Wegrzyn-Wolska, Katarzyna

    This chapter describes the functions of a system proposed for the music hit recommendation from social network data base. This system carries out the automatic collection, evaluation and rating of music reviewers and the possibility for listeners to rate musical hits and recommendations deduced from auditor's profiles in the form of regional Internet radio. First, the system searches and retrieves probable music reviews from the Internet. Subsequently, the system carries out an evaluation and rating of those reviews. From this list of music hits, the system directly allows notation from our application. Finally, the system automatically creates the record list diffused each day depending on the region, the year season, the day hours and the age of listeners. Our system uses linguistics and statistic methods for classifying music opinions and data mining techniques for recommendation part needed for recorded list creation. The principal task is the creation of popular intelligent radio adaptive on auditor's age and region - IA-Regional-Radio.

  4. RADIO VARIABILITY IN SEYFERT NUCLEI

    International Nuclear Information System (INIS)

    Mundell, C. G.; Ferruit, P.; Nagar, N.; Wilson, A. S.

    2009-01-01

    Comparison of 8.4 GHz radio images of a sample of eleven, early-type Seyfert galaxies with previous observations reveals possible variation in the nuclear radio flux density in five of them over a seven year period. Four Seyferts (NGC 2110, NGC 3081, MCG -6-30-15, and NGC 5273) show a decline in their 8.4 GHz nuclear flux density between 1992 and 1999, while one (NGC 4117) shows an increase; the flux densities of the remaining six Seyferts (Mrk 607, NGC 1386, Mrk 620, NGC 3516, NGC 4968, and NGC 7465) have remained constant over this period. New images of MCG -5-23-16 are also presented. We find no correlation between radio variability and nuclear radio luminosity or Seyfert nuclear type, although the sample is small and dominated by type 2 Seyferts. Instead, a possible correlation between the presence of nuclear radio variability and the absence of hundred parsec-scale radio emission is seen, with four out of five marginally resolved or unresolved nuclei showing a change in nuclear flux density, while five out of six extended sources show no nuclear variability despite having unresolved nuclear sources. NGC 2110 is the only source in our sample with significant extended radio structure and strong nuclear variability (∼38% decline in nuclear flux density over seven years). The observed nuclear flux variability indicates significant changes are likely to have occurred in the structure of the nucleus on scales smaller than the VLA beam size (i.e., within the central ∼0.''1 (15 pc)), between the two epochs, possibly due to the appearance and fading of new components or shocks in the jet, consistent with previous detection of subparsec-scale nuclear structure in this Seyfert. Our results suggest that all Seyferts may exhibit variation in their nuclear radio flux density at 8.4 GHz, but that variability is more easily recognized in compact sources in which emission from the variable nucleus is not diluted by unresolved, constant flux density radio jet emission

  5. Radio science investigations with Voyager

    International Nuclear Information System (INIS)

    Eshleman, V.R.; Tyler, G.L.; Croft, T.A.

    1977-01-01

    The planned radio science investigations during the Voyager missions to the outer planets involve: (1) the use of the radio links to and from the spacecraft for occultation measurements of planetary and satellite atmospheres and ionospheres, the rings of Saturn, the solar corona, and the general-relativistic time delay for radiowave propagation through the Sun's gravity field; (2) radio link measurements of true or apparent spacecraft motion caused by the gravity fields of the planets, the masses of their larger satellites, and characteristics of the interplanetary medium; and (3) related measurements which could provide results in other areas, including the possible detection of long-wavelength gravitational radiation propagating through the Solar System. The measurements will be used to study: atmospheric and ionospheric structure, constituents, and dynamics; the sizes, radial distribution, total mass, and other characteristics of the particles in the rings of Saturn; interior models for the major planets and the mean density and bulk composition of a number of their satellites; the plasma density and dynamics of the solar corona and interplanetary medium; and certain fundamental questions involving gravitation and relativity. The instrumentation for these experiments is the same ground-based and spacecraft radio systems as will be used for tracking and communicating with the Voyager spacecraft, although several important features of these systems have been provided primarily for the radio science investigations. (Auth.)

  6. Observations of radio sources or 'What happened to radio stars?'

    International Nuclear Information System (INIS)

    Conway, R.G.

    1988-01-01

    A review is given of the early history of the interpretation of the radiation mechanisms following the discovery of the discrete radio sources, both galactic and extragalactic. The conflicting views which prevailed in the early fifties are discussed in some detail: some advocated thermal radiation from stars relatively close by, and others proposed the alternative that synchrotron radiation was responsible for the majority of the radio sources. Attention is drawn to the importance of high-resolution interferometry, whereby the structure of many of the sources could be obtained. Red-shift measurements and spectral distributions also played a part in determining distances and flux strengths at the sources. (U.K.)

  7. Radio Context Awareness and Applications

    Directory of Open Access Journals (Sweden)

    Luca Reggiani

    2013-01-01

    Full Text Available The context refers to “any information that can be used to characterize the situation of an entity, where an entity can be a person, place, or physical object.” Radio context awareness is defined as the ability of detecting and estimating a system state or parameter, either globally or concerning one of its components, in a radio system for enhancing performance at the physical, network, or application layers. In this paper, we review the fundamentals of context awareness and the recent advances in the main radio techniques that increase the context awareness and smartness, posing challenges and renewed opportunities to added-value applications in the context of the next generation of wireless networks.

  8. Modular Software-Defined Radio

    Directory of Open Access Journals (Sweden)

    Rhiemeier Arnd-Ragnar

    2005-01-01

    Full Text Available In view of the technical and commercial boundary conditions for software-defined radio (SDR, it is suggestive to reconsider the concept anew from an unconventional point of view. The organizational principles of signal processing (rather than the signal processing algorithms themselves are the main focus of this work on modular software-defined radio. Modularity and flexibility are just two key characteristics of the SDR environment which extend smoothly into the modeling of hardware and software. In particular, the proposed model of signal processing software includes irregular, connected, directed, acyclic graphs with random node weights and random edges. Several approaches for mapping such software to a given hardware are discussed. Taking into account previous findings as well as new results from system simulations presented here, the paper finally concludes with the utility of pipelining as a general design guideline for modular software-defined radio.

  9. Unseen cosmos the universe in radio

    CERN Document Server

    Graham-Smith, Francis

    2013-01-01

    Radio telescopes have transformed our understanding of the Universe. Pulsars, quasars, Big Bang cosmology: all are discoveries of the new science of radio astronomy. Here, Francis Graham-Smith describes the birth, development, and maturity of radio astronomy, from the first discovery of cosmic radio waves to its present role as a major part of modern astronomy. Radio is part of the electromagnetic spectrum, covering infra-red, visible light, ultraviolet, X-rays, and gamma-rays, and Graham-Smith explains why it is that radio waves give us a unique view of the Universe. Tracing the development o

  10. Reconfigurable radio systems network architectures and standards

    CERN Document Server

    Iacobucci, Maria Stella

    2013-01-01

    This timely book provides a standards-based view of the development, evolution, techniques and potential future scenarios for the deployment of reconfigurable radio systems.  After an introduction to radiomobile and radio systems deployed in the access network, the book describes cognitive radio concepts and capabilities, which are the basis for reconfigurable radio systems.  The self-organizing network features introduced in 3GPP standards are discussed and IEEE 802.22, the first standard based on cognitive radio, is described. Then the ETSI reconfigurable radio systems functional ar

  11. Miniature EVA Software Defined Radio

    Science.gov (United States)

    Pozhidaev, Aleksey

    2012-01-01

    As NASA embarks upon developing the Next-Generation Extra Vehicular Activity (EVA) Radio for deep space exploration, the demands on EVA battery life will substantially increase. The number of modes and frequency bands required will continue to grow in order to enable efficient and complex multi-mode operations including communications, navigation, and tracking applications. Whether conducting astronaut excursions, communicating to soldiers, or first responders responding to emergency hazards, NASA has developed an innovative, affordable, miniaturized, power-efficient software defined radio that offers unprecedented power-efficient flexibility. This lightweight, programmable, S-band, multi-service, frequency- agile EVA software defined radio (SDR) supports data, telemetry, voice, and both standard and high-definition video. Features include a modular design, an easily scalable architecture, and the EVA SDR allows for both stationary and mobile battery powered handheld operations. Currently, the radio is equipped with an S-band RF section. However, its scalable architecture can accommodate multiple RF sections simultaneously to cover multiple frequency bands. The EVA SDR also supports multiple network protocols. It currently implements a Hybrid Mesh Network based on the 802.11s open standard protocol. The radio targets RF channel data rates up to 20 Mbps and can be equipped with a real-time operating system (RTOS) that can be switched off for power-aware applications. The EVA SDR's modular design permits implementation of the same hardware at all Network Nodes concept. This approach assures the portability of the same software into any radio in the system. It also brings several benefits to the entire system including reducing system maintenance, system complexity, and development cost.

  12. Radio-opaque dental compositions

    International Nuclear Information System (INIS)

    Temin, S.C.

    1979-01-01

    Thorium oxide or tantalum oxide, or combinations thereof are used as the x-ray material for radio-opaque filler compositions having particular applicability in dental restorative compositions. The filler compositions contain from about 3% by weight to about 10% by weight, based on the total filler composition, of the x-ray absorbing materials and the remainder being conventional particulate glass or silica, quarts or ceramic filler material. The radio opaque filler compositions are insoluble and non-leachable in alkaline, acidic or neutral aqueous environments, are essentially non-toxic, are either essentially colorless or translucent, and are compatible with acrylic monomers and other polymerizable binder systems

  13. Synthesis imaging in radio astronomy

    International Nuclear Information System (INIS)

    Perley, R.A.; Schwab, F.R.; Bridle, A.H.

    1989-01-01

    Recent advances in techniques and instrumentation for radio synthesis imaging in astronomy are discussed in a collection of review essays. Topics addressed include coherence in radio astronomy, the interferometer in practice, primary antenna elements, cross correlators, calibration and editing, sensitivity, deconvolution, self-calibration, error recognition, and image analysis. Consideration is given to wide-field imaging (bandwidth and time-average smearing, noncoplanar arrays, and mosaicking), high-dynamic-range imaging, spectral-line imaging, VLBI, solar imaging with a synthesis telescope, synthesis imaging of spatially coherent objects, noise in images of very bright sources, synthesis observing strategies, and the design of aperture-synthesis arrays

  14. New discoveries with radio telescopes

    International Nuclear Information System (INIS)

    Schmidt, J.

    1985-01-01

    The author describes in a simple fashion the results obtained by astronomers from ETH Zurich using the broadband 7-m radio telescope in Switzerland to observe the sun over a period of six years. He explains the results in terms of our present understanding of the sun's workings. The astronomers found that a solar eruption is not a single event but consists of tens of thousands of small eruptions or spikes each only 200 km high and producing a burst of radio waves 10-100 times as intense as the background. (T.J.R.A.)

  15. Origin of solar radio waves

    International Nuclear Information System (INIS)

    Olmr, J.

    1977-01-01

    Solar radiowave radiation amounts to about 10 -7 of the total solar radiation. The solar atmosphere emits radiation of different wavelengths from a fraction of nanometer to kilometer waves. The solar radiowaves are of thermal origin and except for neutral hydrogen emission and solid body radio emission their emission always results from free electrons. The radiowave radiation active components were classified in several types, such as noise storms, flashes, flares, continuum, and flashes lasting for several minutes. The respective types are discussed and their origins shown. The mechanisms are described permitting the formation of radio waves of nonthermal origin, i.e., plasma oscillations, gyromagnetic emission, synchrotron and Cherenkov radiations. (J.P.)

  16. Intelligent Cognitive Radio Models for Enhancing Future Radio Astronomy Observations

    Directory of Open Access Journals (Sweden)

    Ayodele Abiola Periola

    2016-01-01

    Full Text Available Radio astronomy organisations desire to optimise the terrestrial radio astronomy observations by mitigating against interference and enhancing angular resolution. Ground telescopes (GTs experience interference from intersatellite links (ISLs. Astronomy source radio signals received by GTs are analysed at the high performance computing (HPC infrastructure. Furthermore, observation limitation conditions prevent GTs from conducting radio astronomy observations all the time, thereby causing low HPC utilisation. This paper proposes mechanisms that protect GTs from ISL interference without permanent prevention of ISL data transmission and enhance angular resolution. The ISL transmits data by taking advantage of similarities in the sequence of observed astronomy sources to increase ISL connection duration. In addition, the paper proposes a mechanism that enhances angular resolution by using reconfigurable earth stations. Furthermore, the paper presents the opportunistic computing scheme (OCS to enhance HPC utilisation. OCS enables the underutilised HPC to be used to train learning algorithms of a cognitive base station. The performances of the three mechanisms are evaluated. Simulations show that the proposed mechanisms protect GTs from ISL interference, enhance angular resolution, and improve HPC utilisation.

  17. Real-time monitoring of disintegration activity of catalytic core domain of HIV-1 integrase using molecular beacon.

    Science.gov (United States)

    Zhang, Da-wei; Zhao, Ming-ming; He, Hong-qiu; Guo, Shun-xing

    2013-09-15

    HIV-1 integrase, an essential enzyme for retroviral replication, is a validated target for anti-HIV therapy development. The catalytic core domain of integrase (IN-CCD) is capable of catalyzing disintegration reaction. In this work, a hairpin-shaped disintegration substrate was designed and validated by enzyme-linked immunosorbent assay; a molecular beacon-based assay was developed for disintegration reaction of IN-CCD. Results showed that the disintegration substrate could be recognized and catalyzed by IN-CCD, and the disintegration reaction can be monitored according to the increase of fluorescent signal. The assay can be applied to real-time detection of disintegration with advantages of simplicity, high sensitivity, and excellent specificity. Copyright © 2013 Elsevier Inc. All rights reserved.

  18. Experimental study of the evanescent-wave photonic sensors response in presence of molecular beacon conformational changes.

    Science.gov (United States)

    Ruiz-Tórtola, Ángela; Prats-Quílez, Francisco; Gónzalez-Lucas, Daniel; Bañuls, María-José; Maquieira, Ángel; Wheeler, Guy; Dalmay, Tamas; Griol, Amadeu; Hurtado, Juan; Bohlmann, Helge; Götzen, Reiner; García-Rupérez, Jaime

    2018-04-17

    An experimental study of the influence of the conformational change suffered by molecular beacon (MB) probes -upon the biorecognition of nucleic acid target oligonucleotides over evanescent wave photonic sensors- is reported. To this end, high sensitivity photonic sensors based on silicon photonic bandgap (PBG) structures were used, where the MB probes were immobilized via their 5' termination. Those MBs incorporate a biotin moiety close to their 3' termination in order to selectively bind a streptavidin molecule to them. The different photonic sensing responses obtained towards the target oligonucleotide detection, when the streptavidin molecule was bound to the MB probes or not, demonstrate the conformational change suffered by the MB upon hybridization, which promotes the displacement of the streptavidin molecule away from the surface of the photonic sensing structure. Schematic diagram of the PBG sensing structure on which the streptavidin-labeled MB probes were immobilized. This article is protected by copyright. All rights reserved.

  19. BEACON/MOD3, 1-D and 2-D 2 Phase Flow and Heat Transfer in Containment, LWR LOCA

    International Nuclear Information System (INIS)

    Broadus, C.R.; Doyle, R.J.; James, S.W.; Lime, J.F.; Mings, W.J.; Ramsthaler, J.A.; Sahota, M.S.

    1982-01-01

    1 - Description of problem or function: The BEACON series of programs is designed to perform a best-estimate analysis of the flow of a mixture of air, water, and steam in a nuclear reactor containment system under loss-of-coolant accident conditions. The code can simulate two-component, two-phase fluid flow in complex geometries using a combination of two-dimensional, one-dimensional, and lumped- parameter representations for the various parts of the system. BEACON/MOD3 contains mass and heat transfer models for wall film and for wall conduction, and is suitable for the evaluation of short- term transients in PWR dry containment systems. The capability to examine the details of a two-components, two-phase flow field in one or two dimensions under nonhomogeneous, nonequilibrium conditions (unequal velocities, unequal temperatures between the two phases) allows analysis of such problems as the calculation of jet impact forces of a fluid leaving a pipe break, the motion of a large pressure wave across a compartment, the variation in flow properties as air is displaced from a compartment by steam and water, the water entrainment or de-entrainment by a high-speed vapor flow, the flow of a flashing liquid, and many other complex nonequilibrium problems of containment system analyses. 2 - Method of solution: The basic Eulerian flow solution procedure is based on the K-FIX two-dimensional two-phase numerical method. Each phase is described by its own density, velocity, and temperature as determined by separate sets of mass, momentum, and energy equations. The two phases are coupled by exchange parameters which model the exchange of mass, momentum, and energy between the two phases. The two sets of field equations are solved with a Eulerian finite- difference technique that implicitly treats the phase transitions and inter-phasic heat transfer in the pressure iteration. The implicit solution is accomplished iteratively without linearization and allows both phases to be

  20. "Molecular beacon"-hosted thioflavin T: Applications for label-free fluorescent detection of iodide and logic operations.

    Science.gov (United States)

    Li, Yan-Yun; Jiang, Xiao-Qin; Lu, Ling-Fei; Zhang, Min; Shi, Guoyue

    2016-04-01

    In this work, we presented a simple, label-free and rapid-responsive fluorescence assay for iodide (I(-)) detection based on "molecular beacon (MB)"-hosted thioflavin T (ThT), achieving a limit of detection as low as 158 nM. The proposed method exhibited very good selectivity to I(-) ions over other anions interference due to the strong binding force between I(-) ions with Hg(2+). Upon the addition of I(-) ions, it would capture Hg(2+) from a T-Hg(2+)-T complex belonging to the MB-like DNA hairpin structure, which eventually quenched the initial fluorescence as output. In addition, it was successfully applied for operation of an integrated DNA logic gate system and to the determination of I(-) in real samples such as human urine. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. BErkeley Atmospheric CO2 Network (BEACON) - Bringing Measurements of CO2 Emissions to a School Near You

    Science.gov (United States)

    Teige, V. E.; Havel, E.; Patt, C.; Heber, E.; Cohen, R. C.

    2011-12-01

    The University of California at Berkeley in collaboration with the Chabot Space and Science Center describe a set of educational programs, workshops, and exhibits based on a multi-node greenhouse gas and air quality monitoring network being deployed over Oakland, California. Examining raw numerical data using highly engaging and effective geo-data visualization tools like Google Earth can make the science come alive for students, and provide a hook for drawing them into deeper investigations. The Climate Science Investigations teacher workshop at the Chabot Space and Science Center will make use of Google Earth, Excel, and other geo-data visualization tools to step students through the process from data acquisition to discovery. Using multiple data sources, including output from the BErkeley Atmospheric CO2 Network (BEACON) project, participants will be encouraged to explore a variety of different modes of data display toward producing a unique, and ideally insightful, illumination of the data.

  2. Basic Investigations of Dynamic Travel Time Estimation Model for Traffic Signals Control Using Information from Optical Beacons

    Science.gov (United States)

    Okutani, Iwao; Mitsui, Tatsuro; Nakada, Yusuke

    In this paper put forward are neuron-type models, i.e., neural network model, wavelet neuron model and three layered wavelet neuron model(WV3), for estimating traveling time between signalized intersections in order to facilitate adaptive setting of traffic signal parameters such as green time and offset. Model validation tests using simulated data reveal that compared to other models, WV3 model works very fast in learning process and can produce more accurate estimates of travel time. Also, it is exhibited that up-link information obtainable from optical beacons, i.e., travel time observed during the former cycle time in this case, makes a crucial input variable to the models in that there isn't any substantial difference between the change of estimated and simulated travel time with the change of green time or offset when up-link information is employed as input while there appears big discrepancy between them when not employed.

  3. LOW-POWER RADIO GALAXIES IN THE DISTANT UNIVERSE: A SEARCH FOR FR I AT 1 < z < 2 IN THE COSMOS FIELD

    International Nuclear Information System (INIS)

    Chiaberge, Marco; Tremblay, Grant; Macchetto, F. Duccio; Sparks, W. B.; Capetti, Alessandro; Tozzi, Paolo

    2009-01-01

    We present a search for FR I radio galaxies between 1 < z < 2 in the COSMOS field. In absence of spectroscopic redshift measurements, the selection method is based on multiple steps which make use of both radio and optical constraints. The basic assumptions are that (1) the break in radio power between low-power FR Is and the more powerful FR IIs does not change with redshift, and (2) that the photometric properties of the host galaxies of low-power radio galaxies in the distant universe are similar to those of FR IIs in the same redshift bin, as is the case for nearby radio galaxies. We describe the results of our search, which yields 37 low-power radio galaxy candidates that are possibly FR Is. We show that a large fraction of these low-luminosity radio galaxies display a compact radio morphology that does not correspond to the FR I morphological classification. Furthermore, our objects are apparently associated with galaxies that show clear signs of interactions, at odds with the typical behavior observed in low-z FR I hosts. The compact radio morphology might imply that we are observing intrinsically small and possibly young objects that will eventually evolve into the giant FR Is we observe in the local universe. One of the objects appears as pointlike in Hubble Space Telescope (HST) images. This might belong to a population of FR I-QSOs, which however would represent a tiny minority of the overall population of high-z FR Is. As for the local FR Is, a large fraction of our objects are likely to be associated with groups or clusters, making them 'beacons' for high-redshift clusters of galaxies. Our search for candidate high-z FR Is we present in this paper constitutes a pilot study for objects to be observed with future high-resolution and high-sensitivity instruments such as the EVLA and ALMA in the radio band, HST/WFC3 in the optical and IR, James Webb Space Telescope in the IR, as well as future generation X-ray satellites.

  4. How a Beacon Community Program in New Orleans Helped Create a Better Health Care System by Building Relationships before Technology.

    Science.gov (United States)

    Khurshid, Anjum; Brown, Lisanne

    2014-01-01

    In the aftermath of Hurricane Katrina, much of New Orleans' healthcare infrastructure was destroyed. Initial federal funding after the storm expanded primary care services and helped set up medical homes for New Orleans' large uninsured and underinsured population. Following that, the Beacon Community in New Orleans, charged with improving health care through the use of technology, decided the best way to accomplish those goals was to build community partnerships and introduce technology improvements based on their input and on their terms. The purpose of this paper is to describe how those partnerships were wrought, including the innovative use of a conceptual framework, and how they are being sustained; how different technologies were and are being introduced; and what the results have been so far. Past successful community experiences, as well as a proven conceptual framework, were used to help establish community partnerships and governance structures, as well as to demonstrate their linkages. This paper represents a compilation of reports and information from key Beacon leaders, staff and providers and their firsthand experiences in setting up those structures, as well as their conclusions. The community partnerships proved extremely successful in not only devising successful ways to introduce new technology into healthcare settings, but in sustaining those changes by creating a governance structure that has enough fluidity to adapt to changing circumstances. Building and developing community partnerships takes time and effort; however, these relationships are necessary and essential to introducing and sustaining new technologies in a healthcare setting and should be a first step for any organization looking to accomplish such goals.

  5. Gastroesophageal reflux in relation to adenocarcinomas of the esophagus: a pooled analysis from the Barrett's and Esophageal Adenocarcinoma Consortium (BEACON.

    Directory of Open Access Journals (Sweden)

    Michael B Cook

    Full Text Available Previous studies have evidenced an association between gastroesophageal reflux and esophageal adenocarcinoma (EA. It is unknown to what extent these associations vary by population, age, sex, body mass index, and cigarette smoking, or whether duration and frequency of symptoms interact in predicting risk. The Barrett's and Esophageal Adenocarcinoma Consortium (BEACON allowed an in-depth assessment of these issues.Detailed information on heartburn and regurgitation symptoms and covariates were available from five BEACON case-control studies of EA and esophagogastric junction adenocarcinoma (EGJA. We conducted single-study multivariable logistic regressions followed by random-effects meta-analysis. Stratified analyses, meta-regressions, and sensitivity analyses were also conducted.Five studies provided 1,128 EA cases, 1,229 EGJA cases, and 4,057 controls for analysis. All summary estimates indicated positive, significant associations between heartburn/regurgitation symptoms and EA. Increasing heartburn duration was associated with increasing EA risk; odds ratios were 2.80, 3.85, and 6.24 for symptom durations of <10 years, 10 to <20 years, and ≥20 years. Associations with EGJA were slighter weaker, but still statistically significant for those with the highest exposure. Both frequency and duration of heartburn/regurgitation symptoms were independently associated with higher risk. We observed similar strengths of associations when stratified by age, sex, cigarette smoking, and body mass index.This analysis indicates that the association between heartburn/regurgitation symptoms and EA is strong, increases with increased duration and/or frequency, and is consistent across major risk factors. Weaker associations for EGJA suggest that this cancer site has a dissimilar pathogenesis or represents a mixed population of patients.

  6. Perkembangan dan Problematika Radio Komunitas di Indonesia

    Directory of Open Access Journals (Sweden)

    Masduki .

    2013-12-01

    Full Text Available Abstract: This article is about the development of community radio in Indonesia, it is problems and solutions. Community radio in Indonesia developed as an alternative to both public radio and commercial radio after the fall of Soeharto in 1998. Two important features of community radio are that it provides all community members with equal access to information, enhancing their rights and obligations, access to justice, public accountability and also enables them to participate actively in radio management and production. Both features enhance people’s selfawareness and sense of belonging to a community. The expansion of the progressive, participatory, community ownership, and non-profit model of community radio, has become a third sector of communication beside the commercial or state media. The dynamic development of community radio in Indonesia faced several problems starting from it is definition, implementation of regulation until standards of programmes operation based on the concept of community approach and participation

  7. Interweave Cognitive Radio with Improper Gaussian Signaling

    KAUST Repository

    Hedhly, Wafa; Amin, Osama; Alouini, Mohamed-Slim

    2018-01-01

    Improper Gaussian signaling (IGS) has proven its ability in improving the performance of underlay and overlay cognitive radio paradigms. In this paper, the interweave cognitive radio paradigm is studied when the cognitive user employs IGS

  8. Contribution Towards Practical Cognitive Radios Systems

    KAUST Repository

    Ben Ghorbel, Mahdi

    2013-01-01

    to cognitive radio systems while taking into account practical constraints. Cogni- tive radios requires a capability to detect spectrum holes (spectrum sensing) and a scheduling flexibility to avoid the occupied spectrum and selectively use the empty spectrum

  9. Educational Radio: The Brazilian Experience.

    Science.gov (United States)

    Speyer, Anne Marie

    1983-01-01

    Explains the value of radio for literacy education, gives a synopsis of the development of educational broadcasting in Brazil, and describes the Movement of Basic Education, a program designed to meet the needs of members of rural communities in their daily working lives. (EAO)

  10. Hybrid spread spectrum radio system

    Science.gov (United States)

    Smith, Stephen F [London, TN; Dress, William B [Camas, WA

    2010-02-09

    Systems and methods are described for hybrid spread spectrum radio systems. A method, includes receiving a hybrid spread spectrum signal including: fast frequency hopping demodulating and direct sequence demodulating a direct sequence spread spectrum signal, wherein multiple frequency hops occur within a single data-bit time and each bit is represented by chip transmissions at multiple frequencies.

  11. Radio frequency modulation made easy

    CERN Document Server

    Faruque, Saleh

    2017-01-01

    This book introduces Radio Frequency Modulation to a broad audience. The author blends theory and practice to bring readers up-to-date in key concepts, underlying principles and practical applications of wireless communications. The presentation is designed to be easily accessible, minimizing mathematics and maximizing visuals.

  12. The isotropic radio background revisited

    Energy Technology Data Exchange (ETDEWEB)

    Fornengo, Nicolao; Regis, Marco [Dipartimento di Fisica Teorica, Università di Torino, via P. Giuria 1, I–10125 Torino (Italy); Lineros, Roberto A. [Instituto de Física Corpuscular – CSIC/U. Valencia, Parc Científic, calle Catedrático José Beltrán, 2, E-46980 Paterna (Spain); Taoso, Marco, E-mail: fornengo@to.infn.it, E-mail: rlineros@ific.uv.es, E-mail: regis@to.infn.it, E-mail: taoso@cea.fr [Institut de Physique Théorique, CEA/Saclay, F-91191 Gif-sur-Yvette Cédex (France)

    2014-04-01

    We present an extensive analysis on the determination of the isotropic radio background. We consider six different radio maps, ranging from 22 MHz to 2.3 GHz and covering a large fraction of the sky. The large scale emission is modeled as a linear combination of an isotropic component plus the Galactic synchrotron radiation and thermal bremsstrahlung. Point-like and extended sources are either masked or accounted for by means of a template. We find a robust estimate of the isotropic radio background, with limited scatter among different Galactic models. The level of the isotropic background lies significantly above the contribution obtained by integrating the number counts of observed extragalactic sources. Since the isotropic component dominates at high latitudes, thus making the profile of the total emission flat, a Galactic origin for such excess appears unlikely. We conclude that, unless a systematic offset is present in the maps, and provided that our current understanding of the Galactic synchrotron emission is reasonable, extragalactic sources well below the current experimental threshold seem to account for the majority of the brightness of the extragalactic radio sky.

  13. The isotropic radio background revisited

    International Nuclear Information System (INIS)

    Fornengo, Nicolao; Regis, Marco; Lineros, Roberto A.; Taoso, Marco

    2014-01-01

    We present an extensive analysis on the determination of the isotropic radio background. We consider six different radio maps, ranging from 22 MHz to 2.3 GHz and covering a large fraction of the sky. The large scale emission is modeled as a linear combination of an isotropic component plus the Galactic synchrotron radiation and thermal bremsstrahlung. Point-like and extended sources are either masked or accounted for by means of a template. We find a robust estimate of the isotropic radio background, with limited scatter among different Galactic models. The level of the isotropic background lies significantly above the contribution obtained by integrating the number counts of observed extragalactic sources. Since the isotropic component dominates at high latitudes, thus making the profile of the total emission flat, a Galactic origin for such excess appears unlikely. We conclude that, unless a systematic offset is present in the maps, and provided that our current understanding of the Galactic synchrotron emission is reasonable, extragalactic sources well below the current experimental threshold seem to account for the majority of the brightness of the extragalactic radio sky

  14. Utrecht and Galactic Radio Astronomy

    NARCIS (Netherlands)

    van Woerden, H.

    Important roles in early Dutch Galactic radio astronomy were played by several Utrecht astronomers: Van de Hulst, Minnaert and Houtgast. The poster announcing the conference contained a number of pictures referring to scientific achievements of the Astronomical Institute Utrecht. One of these

  15. A repeating fast radio burst.

    Science.gov (United States)

    Spitler, L G; Scholz, P; Hessels, J W T; Bogdanov, S; Brazier, A; Camilo, F; Chatterjee, S; Cordes, J M; Crawford, F; Deneva, J; Ferdman, R D; Freire, P C C; Kaspi, V M; Lazarus, P; Lynch, R; Madsen, E C; McLaughlin, M A; Patel, C; Ransom, S M; Seymour, A; Stairs, I H; Stappers, B W; van Leeuwen, J; Zhu, W W

    2016-03-10

    Fast radio bursts are millisecond-duration astronomical radio pulses of unknown physical origin that appear to come from extragalactic distances. Previous follow-up observations have failed to find additional bursts at the same dispersion measure (that is, the integrated column density of free electrons between source and telescope) and sky position as the original detections. The apparent non-repeating nature of these bursts has led to the suggestion that they originate in cataclysmic events. Here we report observations of ten additional bursts from the direction of the fast radio burst FRB 121102. These bursts have dispersion measures and sky positions consistent with the original burst. This unambiguously identifies FRB 121102 as repeating and demonstrates that its source survives the energetic events that cause the bursts. Additionally, the bursts from FRB 121102 show a wide range of spectral shapes that appear to be predominantly intrinsic to the source and which vary on timescales of minutes or less. Although there may be multiple physical origins for the population of fast radio bursts, these repeat bursts with high dispersion measure and variable spectra specifically seen from the direction of FRB 121102 support an origin in a young, highly magnetized, extragalactic neutron star.

  16. Quality in radio-immunology

    International Nuclear Information System (INIS)

    Hegesippe, Michel

    1982-01-01

    The author outlines the technique of radio-immunological analysis (RIA) which is now widely used for neo-natal detection of congenital hyperthyroidism. He describes the methods and controls that are called for - as regards the specificity of doses, the sensitivity and reliability of the separation technique - to guarantee the quality of RIA and the validity of its results [fr

  17. Newnes radio and electronics engineer's pocket book

    CERN Document Server

    Moorshead, H W; Perry, J

    1978-01-01

    Newnes Radio and Electronics Engineer's Pocket Book, Fifteenth Edition provides reference of the information relevant in radio and electronics engineering. The book presents tables, illustrations, and diagrams of various data used in radio and electronics engineering. The coverage of the text includes abbreviations and symbols, electrical equations, and code conversions. The text will be useful to engineers, technicians, and other professionals who require a reference about the different aspects of radio and electronics.

  18. IRAS observations of radio-quiet and radio-loud quasars

    Science.gov (United States)

    Neugebauer, G.; Soifer, B. T.; Miley, G.; Habing, H. J.; Young, E.; Low, F. J.; Beichman, C. A.; Clegg, P. E.; Harris, S.; Rowan-Robinson, M.

    1984-01-01

    Observations from 12 to 100 microns are presented of two radio-quiet and three radio-loud quasars. Over this wavelength range, all five have grossly similar continuum energy distributions. The continua of the radio-loud quasars are consistent with synchrotron radiation. There is an indication, however, of excess 100 micron emission in the two radio-quiet quasars.

  19. Division B Commission 40: Radio Astronomy

    NARCIS (Netherlands)

    Chapman, Jessica M.; Giovaninni, Gabriele; Taylor, Russell; Carilli, Christopher; Hills, Richard; Hirabayashi, Hisashi; Jonas, Justin L.; Lazio, Joseph; Morganti, Raffaella; Nan, Rendong; Rubio, Monica; Shastri, Prjaval; Kellermann, Ken; Ekers, Ronald; Ohishi, Masatoshi

    2016-01-01

    IAU Commission 40 for Radio Astronomy (hereafter C40) brought together scientists and engineers who carry out observational and theoretical research in radio astronomy and who develop and operate the ground and space-based radio astronomy facilities and instrumentation. As of June 2015, the

  20. Exploring Community Radio Programming Practices to Inform ...

    African Journals Online (AJOL)

    A collective case study (multi-site) design was used to probe educational programming practices used in community radio. The paper explores how community radio station programming engages listeners in community generated education programmes that are produced through collaborative work with radio listener clubs.

  1. Politics and Radio in the 1924 Campaign.

    Science.gov (United States)

    Berkman, Dave

    1987-01-01

    Discusses the relation between radio broadcasting and politics in the 1924 presidential campaign, focusing on newspaper and magazine coverage. Notes radio's influence on candidate image, the aspect of censorship, and the use of radio during the campaign and after the election. (MM)

  2. The Effect of Solar Radiation on Radio Signal for Radio Astronomy Purposes

    International Nuclear Information System (INIS)

    Nor Hazmin Sabri; Atiq Wahidah Azlan; Roslan Umar; Roslan Umar; Shahirah Syafa Sulan; Zainol Abidin Ibrahim; Wan Zul Adli Wan Mokhtar

    2015-01-01

    Radio astronomy is a subfields of astronomy which is discovers the celestial objects at radio frequencies. Observation in radio astronomy is conducted using single antenna or array of antennas, known as radio telescope. Other than that, radio astronomy also holds an advantage over other alternatives to optical astronomy due to its capability of observing from the ground level. In this study, the effect of solar radiation that contributes the Radio Frequency Interferences (RFI) is reviewed. The low RFI level is required to set up the radio telescope for radio astronomy observation. The effect of solar radiation on radio signal was investigated by determining the RFI pattern using spectrum analyzer. The solar radiation data was obtained from weather station located at KUSZA Observatory, East Coast Environmental Research Institute (ESERI), UniSZA. We can conclude that the solar radiation factor give the minimum significant effect to radio signal. (author)

  3. The height of electron content changes in the ionosphere from ATS6 beacon data

    International Nuclear Information System (INIS)

    Davies, K.; Heron, M.L.

    1984-01-01

    A technique is described which uses relative changes in Faraday rotation and modulation phase of satellite radio signals to determine the median height of the enhancement (or depletion) in the electron density of the ionosphere. During the post sunrise formation of the F layer the incremental layers have a median height of around 210 km (+- 40) and in the afternoon the decremental median is above the peak at 340 km (+- 40) on a winter day. A winter night-time enhancement just after midnight appears as a thick layer extending upwards from the peak, with a median height at about 730 km. The method applies to large scale irregularities but not to small, dense, scintillation-causing irregularities for which Faraday and modulation phases do not represent the total electron content. (author)

  4. Radio Astronomy Explorer (RAE) 1 observations of terrestrial radio noise

    Science.gov (United States)

    Herman, J. R.; Caruso, J. A.

    1971-01-01

    Radio Astonomy Explorer (RAE) 1 data are analyzed to establish characteristics of HF terrestrial radio noise at an altitude of about 6000 km. Time and frequency variations in amplitude of the observed noise well above cosmic noise background are explained on the basis of temporal and spatial variations in ionospheric critical frequency coupled with those in noise source distributions. It is shown that terrestrial noise regularly breaks through the ionosphere and reaches RAE with magnitudes 15 or more db higher than cosmic noise background. Maximum terrestrial noise is observed when RAE is over the dark side of the Earth in the neighborhood of equatorial continental land masses where thunderstorms occur most frequently. The observed noise level is 30-40 db lower with RAE over oceans.

  5. Fast Radio Bursts and Radio Transients from Black Hole Batteries

    OpenAIRE

    Mingarelli, Chiara M. F.; Levin, Janna; Lazio, T. Joseph W.

    2015-01-01

    Most black holes (BHs) will absorb a neutron star (NS) companion fully intact without tidal disruption, suggesting the pair will remain dark to telescopes. Even without tidal disruption, electromagnetic (EM) luminosity is generated from the battery phase of the binary when the BH interacts with the NS magnetic field. Originally, the luminosity was expected to be in high-energy X-rays or gamma-rays, however, we conjecture that some of the battery power is emitted in the radio bandwidth. While ...

  6. Radio halo sources in clusters of galaxies

    International Nuclear Information System (INIS)

    Hanisch, R.J.

    1986-01-01

    Radio halo sources remain one of the most enigmatic of all phenomena related to radio emission from galaxies in clusters. The morphology, extent, and spectral structure of these sources are not well known, and the models proposed to explain them suffer from this lack of observational detail. However, recent observations suggest that radio halo sources may be a composite of relic radio galaxies. The validity of this model could be tested using current and planned high resolutions, low-frequency radio telescopes. 31 references

  7. Radio investigations of clusters of galaxies

    International Nuclear Information System (INIS)

    Valentijn, E.A.

    1978-01-01

    This thesis contains a number of papers of the series entitled, A Westerbork Survey of Rich Clusters of Galaxies. The primary aim was to study the radio characteristics of cluster galaxies and especially the question whether their ''radio-activity'' is influenced by their location inside a cluster. It is enquired whether the presence of an intra-cluster medium (ICM), or the typical cluster evolution or cluster dynamical processes can give rise to radio-observable effects on the behaviour of cluster galaxies. 610 MHz WSRT observations of the Coma cluster (and radio observations of the Hercules supercluster) are presented. Extended radio sources in Abell clusters are then described. (Auth.)

  8. A molecular beacon based on DNA-templated silver nanoclusters for the highly sensitive and selective multiplexed detection of virulence genes.

    Science.gov (United States)

    Han, Dan; Wei, Chunying

    2018-05-01

    In this work, we develop a fluorescent molecular beacon based on the DNA-templated silver nanoclusters (DNA-Ag NCs). The skillfully designed molecular beacon can be conveniently used for detection of diverse virulence genes as long as the corresponding recognition sequences are embedded. Importantly, the constructed detection system allows simultaneous detection of multiple nucleic acids, which is attributed to non-overlapping emission spectra of the as-synthesized silver nanoclusters. Based on the target-induced fluorescence enhancement, three infectious disease-related genes HIV, H1N1, and H5N1 are detected, and the corresponding detection limits are 3.53, 0.12 and 3.95nM, respectively. This design allows specific, versatile and simultaneous detection of diverse targets with easy operation and low cost. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. In-cell protease assay systems based on trans-localizing molecular beacon proteins using HCV protease as a model system.

    Directory of Open Access Journals (Sweden)

    Jeong Hee Kim

    Full Text Available This study describes a sensitive in-cell protease detection system that enables direct fluorescence detection of a target protease and its inhibition inside living cells. This live-cell imaging system provides a fluorescent molecular beacon protein comprised of an intracellular translocation signal sequence, a protease-specific cleavage sequence, and a fluorescent tag sequence(s. The molecular beacon protein is designed to change its intracellular localization upon cleavage by a target protease, i.e., from the cytosol to a subcellular organelle or from a subcellular organelle to the cytosol. Protease activity can be monitored at the single cell level, and accordingly the entire cell population expressing the protease can be accurately enumerated. The clear cellular change in fluorescence pattern makes this system an ideal tool for various life science and drug discovery research, including high throughput and high content screening applications.

  10. Propagation engineering in radio links design

    CERN Document Server

    Ghasemi, Abdollah; Ghasemi, Farshid

    2013-01-01

    Propagation Engineering in Radio Link Design covers the basic principles of radiowaves propagation in a practical manner.  This fundamental understanding enables the readers to design radio links efficiently. This book elaborates on new achievements as well as recently developed propagation models.  This is in addition to a comprehensive overview of fundamentals of propagation in various scenarios. It examines theoretical calculations, approaches and applied procedures needed for radio links design. The authors study and analysis of the main propagation phenomena and its mechanisms based on the recommendations of International Telecommunications Union, (ITU). The book has been organized in 9 chapters and examines the role of antennas and passive reflectors in radio services, propagation mechanisms related to radar, satellite, short distance, broadcasting and trans-horizon radio links, with two chapters devoted to radio noise and main  parameters of radio link design. The book presents some 278 illustration...

  11. Precision Geodesy via Radio Interferometry.

    Science.gov (United States)

    Hinteregger, H F; Shapiro, I I; Robertson, D S; Knight, C A; Ergas, R A; Whitney, A R; Rogers, A E; Moran, J M; Clark, T A; Burke, B F

    1972-10-27

    Very-long-baseline interferometry experiments, involving observations of extragalactic radio sources, were performed in 1969 to determine the vector separations between antenna sites in Massachusetts and West Virginia. The 845.130-kilometer baseline was estimated from two separate experiments. The results agreed with each other to within 2 meters in all three components and with a special geodetic survey to within 2 meters in length; the differences in baseline direction as determined by the survey and by interferometry corresponded to discrepancies of about 5 meters. The experiments also yielded positions for nine extragalactic radio sources, most to within 1 arc second, and allowed the hydrogen maser clocks at the two sites to be synchronized a posteriori with an uncertainty of only a few nanoseconds.

  12. Recent radio studies of SNR

    International Nuclear Information System (INIS)

    Dickel, J.R.

    1983-01-01

    SNR can generally be recognized as extended sources of continuum radio emission with non-thermal spectra located near the galactic plane. The author describes the kinds of observations currently being obtained and what they tell us about the objects. The data include continuum observations which can reach resolutions of about 1 arcsec using aperture synthesis techniques and also spectral line observations of the interstellar matter being encountered by the remnants. (Auth.)

  13. Superconducting Radio-Frequency Cavities

    Science.gov (United States)

    Padamsee, Hasan S.

    2014-10-01

    Superconducting cavities have been operating routinely in a variety of accelerators with a range of demanding applications. With the success of completed projects, niobium cavities have become an enabling technology, offering upgrade paths for existing facilities and pushing frontier accelerators for nuclear physics, high-energy physics, materials science, and the life sciences. With continued progress in basic understanding of radio-frequency superconductivity, the performance of cavities has steadily improved to approach theoretical capabilities.

  14. Identification of southern radio sources

    International Nuclear Information System (INIS)

    Savage, A.; Bolton, J.G.; Wright, A.E.

    1976-01-01

    Identifications are suggested for 36 radio sources from the southern zones of the Parkes 2700 MHz survey, 28 with galaxies, six with confirmed and two with suggested quasi-stellar objects. The identifications were made from the ESO quick blue survey plates, the SRC IIIa-J deep survey plates and the Palomar sky survey prints. Accurate optical positions have also been measured for nine of the objects and for five previously suggested identifications. (author)

  15. LEP Radio Frequency Copper Cavity

    CERN Multimedia

    The pulse of a particle accelerator. 128 of these radio frequency cavities were positioned around CERN's 27-kilometre LEP ring to accelerate electrons and positrons. The acceleration was produced by microwave electric oscillations at 352 MHz. The electrons and positrons were grouped into bunches, like beads on a string, and the copper sphere at the top stored the microwave energy between the passage of individual bunches. This made for valuable energy savings as it reduced the heat generated in the cavity.

  16. Expanding radio astronomy in Africa

    International Nuclear Information System (INIS)

    Gaylard, M J

    2013-01-01

    The Square Kilometre Array (SKA) Organisation announced in May 2012 that its members had agreed on a dual site solution for the SKA [1]. South Africa's bid for hosting the SKA has caused a ramp up of radio astronomy in Africa. To develop technology towards the SKA, the South African SKA Project (SKA SA) built a protoype radio telescope in 2007, followed in 2010 the seven antenna Karoo Array Telescope (KAT-7). Next is the 64 antenna MeerKAT, which will merge into SKA Phase 1 in Africa. As SKA Phase 2 is intended to add a high resolution capability with baselines out to 3000 km, the SKA SA brought in partner countries in Africa to host outstations. South Africa has been working with the partners to build capacity to operate the SKA and to benefit from it. The SA Department of Science and Technology (DST) developed a proposal to establish radio telescopes in the partner countries to provide hands-on learning and a capability for Very Long Baseline Interferometry (VLBI) research. Redundant 30 m class satellite antennas are being incorporated in this project.

  17. Radio outbursts in extragalactic sources

    International Nuclear Information System (INIS)

    Kinzel, W.M.

    1989-01-01

    Three aspects of the flux density variability of extragalactic radio sources were examined: millimeter wavelength short timescale variability, the spectral evolution of outbursts, and whether the outbursts are periodically spaced. Observations of extragalactic radio sources were conducted using the Five College Radio Astronomy Observatory between January and June 1985 at 88.2 GHz and during June and July 1985 at 40.0 GHz. Many of the sources exhibited significant flux density variations during the observing span. In addition, the most rapid variations observed were comparable with those reported in previous works. Two sources, 0355+50 and OJ287, both exhibited outbursts whose rise and fall timescales were less than a month. An anomalous flux density dropout was observed in 3C446 and was interpreted as an occultation event. Data at five frequencies between 2.7 and 89.6 GHz from the Dent-Balonek monitoring program were used to investigate the spectral evolution of eight outbursts. Outburst profile fitting was used to deconvolve the individual outbursts from one another at each frequency. The fit profiles were used to generate multiple epoch spectra to investigate the evolution of the outbursts. A phase residual minimization method was used to examine four sources for periodic behavior

  18. Advances in solar radio astronomy

    Science.gov (United States)

    Kundu, M. R.

    1982-01-01

    The status of the observations and interpretations of the sun's radio emission covering the entire radio spectrum from millimeter wavelengths to hectometer and kilometer wavelengths is reviewed. Emphasis is given to the progress made in solar radio physics as a result of recent advances in plasma and radiation theory. It is noted that the capability now exists of observing the sun with a spatial resolution of approximately a second of arc and a temporal resolution of about a millisecond at centimeter wavelengths and of obtaining fast multifrequency two-dimensional pictures of the sun at meter and decameter wavelengths. A summary is given of the properties of nonflaring active regions at millimeter, centimeter, and meter-decameter wavelengths. The properties of centimeter wave bursts are discussed in connection with the high spatial resolution observations. The observations of the preflare build-up of an active region are reviewed. High spatial resolution observations (a few seconds of arc to approximately 1 arcsec) are discussed, with particular attention given to the one- and two-dimensional maps of centimeter-wavelength burst sources.

  19. Workshop on Radio Recombination Lines

    CERN Document Server

    1980-01-01

    Since their first detection 15 years ago, radio recombination lines from several elements have been observed in a wide variety of objects including HII regions, planetary nebulae, molecular clouds, the diffuse interstellar medium, and recently, other galaxies. The observations span almost the entire range from 0.1 to 100 GHz, and employ both single­ djsh and aperture synthesis techniques. The theory of radio recombination lines has also advanced strongly, to the point where it is perhaps one of the best-understood in astro­ physics. In a parallel development, it has become possible over the last decade to study these same highly-excited atoms in the laboratory; this work provides further confirmation of the theoretical framework. However there has been continuing controversy over the astrophysical interpre­ tation of radio recombination line observations, especially regarding the role of stimulated emission. A workshop was held in Ottawa on 24-25 August, 1979, bringing together many of the active scientist...

  20. Molecular beacon based biosensor for the sequence-specific detection of DNA using DNA-capped gold nanoparticles-streptavidin conjugates for signal amplification

    International Nuclear Information System (INIS)

    Fang, Xian; Jiang, Wei; Han, Xiaowei; Zhang, Yuzhong

    2013-01-01

    We describe a highly sensitive and selective molecular beacon-based electrochemical impedance biosensor for the sequence-specific detection of DNA. DNA-capped conjugates between gold nanoparticles (Au-NPs) and streptavidin are used for signal amplification. The molecular beacon was labeled with a thiol at its 5′ end and with biotin at its 3′ end, and then immobilized on the surface of a bare gold electrode through the formation of Au-S bonds. Initially, the molecular beacon is present in the “closed” state, and this shields the biotin from being approached by streptavidin due to steric hindrance. In the presence of the target DNA, the target DNA molecules hybridize with the loop and cause a conformational change that moves the biotin away from the surface of the electrode. The biotin thereby becomes accessible for the reporter (the DNA-streptavidin capped Au-NPs), and this results in a distinct increase in electron transfer resistance. Under optimal conditions, the increase in resistance is linearly related to the logarithm of the concentration of complementary target DNA in the range from 1.0 fM to 0.1 μM, with a detection limit of 0.35 fM (at an S/N of 3). This biosensor exhibits good selectivity, and acceptable stability and reproducibility. (author)