WorldWideScience

Sample records for gamma scintigraphic analysis

  1. Gamma scintigraphic analysis of albumin flux in patients with acute respiratory distress syndrome

    International Nuclear Information System (INIS)

    Sugerman, H.J.; Tatum, J.L.; Burke, T.S.; Strash, A.M.; Glauser, F.L.

    1984-01-01

    Computerized gamma-scintigraphy provides a new method for the analysis of albumin flux in patients with pulmonary permeability edema. In this technique, 10 mCi of 99 mTc -tagged human serum albumin is administered and lung:heart radioactivity ratios are determined. This ratio remains constant unless there is a leak of albumin, when a rising ratio with time, called the ''slope index'' (SI), is seen. Thirty-five scintigraphic studies were obtained in 28 patients by means of a portable computerized gamma-camera. Thirteen of these patients had clinical evidence of the acute respiratory distress syndrome (ARDS) and six had or were recovering from left ventricular induced congestive heart failure (CHF). Five of the patients with CHF and pulmonary capillary wedge pressure (PCWP) below 30 mm Hg had normal scintigraphic studies. The patients with ARDS were found to have significantly higher SIs than patients who did not have, or had recovered from, ARDS. Positive SIs were present from 1 to 8 days following the apparent onset of ARDS in seven studies in five patients. Recovery of gas exchange was associated with a return to a normal SI in four patients. In conclusion, computerized gamma-scintigraphy was a sensitive, noninvasive tool for the detection of a pathologic increase in pulmonary protein flux. Positive scintigraphic findings were associated with significantly impaired gas exchange. The method documented that the leak of albumin in patients with ARDS may last for days but resolves with recovery

  2. Gamma camera with an original system of scintigraphic image printing incorporated

    International Nuclear Information System (INIS)

    Roux, G.

    A new gamma camera has been developed, using Anger's Principle to localise the scintillations and incorporating the latest improvements which give a standard of efficiency at present competitive for this kind of apparatus. In the general design of the system special care was devoted to its ease of employment and above all to the production of high-quality scintigraphic images, the recording of images obtained from the gamma camera posing a problem to which a solution is proposed. This consists in storing all the constituent data of an image in a cell matrix of format similar to the scope of the object, the superficial information density of the image being represented by the cell contents. When the examination is finished a special printer supplies a 35x43 cm 2 document in colour on paper, or in black and white on radiological film, at 2:1 or 1:1 magnifications. The laws of contrast representation by the colours or shades of grey are chosen a posteriori according to the organ examined. Documents of the same quality as those so far supplied by a rectilinear scintigraph are then obtained with the gamma camera, which offers its own advantages in addition. The first images acquired in vivo with the whole system, gamma camera plus printer, are presented [fr

  3. Scintigraphic And Ultrasonic Determinations of Thyroid Volume

    International Nuclear Information System (INIS)

    Sarsono; Ismanto; Kunto, W; Hayati, N; Irma, S H

    1996-01-01

    A study has been done on the determination of thyroid volume by scintigraphic method in comparison to ultrasonographic technique, which involved a healthy woman volunteer, 5 women patients and a man patient with thyroid diseases. Scintigraphic examination upon the patient's thyroid was performed using a gamma camera 20 minutes following the injection of 55.5 Mbq (1.5 mCi) Tc-99m pertechnetate. A computer, with a dedicated program, coupled to the gamma camera was employed in the calculation of thyroid volume based on the scintigraphic data. Subsequent to the scintigraphic study, ultrasonographic determination of thyroid volume was then carried out. Correlation test that was applied to the outcome of the two methods of thyroid volume determination resulted in an excellent coefficient of correlation, R, which was 0.99. This showed a very good correlation between these two different techniques of thyroid volume determination

  4. Modeling and analysis of dynamic scintigraphic data for measurement of cardiac perfusion and performance

    International Nuclear Information System (INIS)

    Twieg, D.B.

    1977-01-01

    Clinical scintigraphy is the technique of imaging the distributions of gamma-ray-emitting tracers within a patient's body. The increasingly popular small nuclear medicine computer has greatly facilitated the use of mathematical models for interpretation of scintigraphic data, and has made it possible for the clinician and the researcher to extract from the scintigraphic data information not otherwise available. The purpose of this work was to investigate several models used in dynamic scintigraphic studies of the heart. The Xenon washout method of measuring myocardial perfusion is discussed. The use of single-compartment, multi-compartment, and noncompartmental models are critically examined, and the influence of multiexponential components on monoexponential fits for perfusion measurement from Xenon washouts is investigated. A model of cardiac pump function is developed which allows for incompetent valves at the input and output of the ventricular chamber. An iterative method is used in conjunction with the model to estimate forward and regurgitant flows from simulated noisy scintigraphic data and from patient data. Unlike previously available methods, the method presented here was developed to allow noninvasive determination of both mitral and aortic regurgitation. Simulation results were successful, and preliminary studies in a few patients were encouraging. An investigation is presented into the relationship between the count-volume and geometric scintigraphic methods of estimating left ventricular ejection fraction, an important index of the contractile state of the myocardial muscle. A bias due to failure to account for the effects of Poisson noise was found in one popular method for ejection measurement

  5. Differentiated thyroid carcinoma in a scintigraphically hot nodule: diagnosis and interdisciplinary therapeutical approach

    International Nuclear Information System (INIS)

    Stahl, A.; Hess, U.; Langhammer, H.; Harms, J.; Zwicknagl, M.

    2002-01-01

    A hyperfunctioning differentiated thyroid carcinoma is a rare occurrence. Nevertheless, this diagnosis must be considered in a scintigraphically hot nodule if there is a clinical or sonographic suggestion of malignancy. The case of a 57-year old patient with hyperthyreosis and a scintigraphically hot thyroid nodule is presented. Further evaluation led to the diagnosis of a differentiated thyroid carcinoma with extensive lymph node and pulmonary metastases (pT2b, pN1b, pM1). The scintigraphically hot nodule corresponded to the primary tumor, whereas scintigraphic detection of the lymph node metastases was only possible postoperatively. Extensive resection of the lymph node metastases was achieved by the intraoperative application of a gamma probe (2nd operation). This allowed sufficient uptake of radioiodine in the pulmonary metastases for their detection and subsequent devitalization by radioiodine therapy. Complete elimination of all tumor tissue was documented at a control follow-up after six months. Gamma probe-guided surgery may allow for additional removement of non-palpable lymph node metastases. In selected cases this may optimize the surgical results and thereby facilitate the subsequent radioiodine elimination of advanced differentiated thyroid carcinomas. (author)

  6. Scintigraphic analysis of thyroid diseases at the Lagos University ...

    African Journals Online (AJOL)

    This paper presents a retrospective analysis of randomly selected clinical scintigraphic records at the College of Medicine/Lagos University Teaching Hospital, Nigeria. Out of the 436 patients scanned for various thyroid abnormalities, 266 (61.0%) were used for the analysis due to insufficient data and parameters required ...

  7. 3D tomographic imaging with the γ-eye planar scintigraphic gamma camera

    Science.gov (United States)

    Tunnicliffe, H.; Georgiou, M.; Loudos, G. K.; Simcox, A.; Tsoumpas, C.

    2017-11-01

    γ-eye is a desktop planar scintigraphic gamma camera (100 mm × 50 mm field of view) designed by BET Solutions as an affordable tool for dynamic, whole body, small-animal imaging. This investigation tests the viability of using γ-eye for the collection of tomographic data for 3D SPECT reconstruction. Two software packages, QSPECT and STIR (software for tomographic image reconstruction), have been compared. Reconstructions have been performed using QSPECT’s implementation of the OSEM algorithm and STIR’s OSMAPOSL (Ordered Subset Maximum A Posteriori One Step Late) and OSSPS (Ordered Subsets Separable Paraboloidal Surrogate) algorithms. Reconstructed images of phantom and mouse data have been assessed in terms of spatial resolution, sensitivity to varying activity levels and uniformity. The effect of varying the number of iterations, the voxel size (1.25 mm default voxel size reduced to 0.625 mm and 0.3125 mm), the point spread function correction and the weight of prior terms were explored. While QSPECT demonstrated faster reconstructions, STIR outperformed it in terms of resolution (as low as 1 mm versus 3 mm), particularly when smaller voxel sizes were used, and in terms of uniformity, particularly when prior terms were used. Little difference in terms of sensitivity was seen throughout.

  8. Scintigraphic measurements of gastric emptying corrected for differences in tissue attenuation

    Energy Technology Data Exchange (ETDEWEB)

    Lauritzen, J.B.; Hoejgaard, L.; Uhrenholdt, A. (Copenhagen Univ. (Denmark). Hvidovre Hospital)

    1983-10-01

    In order to evaluate the importance of variations in tissue attenuation in scintigraphic measurements of gastric emptying, both in vivo and in vitro measurements of count rates from an encapsulated sup(99m)Tc dose were performed in different parts of the stomach. The obtained individual tissue correction factors were applied in the calculation of gastric emptying rates by gamma camera in healthy volunteers. The results showed that the anterior gamma camera scan without correction for differences in tissue attenuation underestimated the gastric emptying rate by 11% if the results were expressed as percentage meal emptied over 60 minutes.

  9. Parallel scintigraphic and echographic studies in patients with miscellaneous andrologic diseases

    International Nuclear Information System (INIS)

    Sultanov, S.; Stanchev, P.; Tsvetkov, D.

    1989-01-01

    The diagnostic possibilities of scintigraphic and echographic methods are compared for diagnostics of varicocele, cryptorchidism, orchiepididymitis, atrophy of the testis, post orchidopexy state, tumors, torsion and hypogonadism. A nonselected group of 33 patients is studied. In 24 patients was coincidence in the results from gamma camera scintigraphy and echography, in 7 - lack of coincidence and in 3 - partial coincidence. It is concludied that the two methods are quick, exact and noninvasive. Gamma-camera scintigraphy is especially suitable for torsion, where the diagnosis is infallible, for cryptorchidism, varicocele and for tumors, where the necrotic zones in the testis are very precisely visualized. 3 figs., 4 refs

  10. The use of 111In-labelled platelets for scintigraphic localization of gastrointestinal bleeding with special reference to occult bleeding

    International Nuclear Information System (INIS)

    Gjerloeff Schmidt, K.; Waever Rasmussen, J.; Grove, O.; Andersen, D.

    1986-01-01

    Gamma-camera imaging of the abdomen after injection of autologous 111 In-labelled platelets was applied for localization of gastrointestinal bleeding in a study of 22 patients. In 15 studies showing scintigraphic signs of bleeding, the clinical presentation included occult bleeding in 6, melaena in 4, and bloody stools in 5 patients. Scintigraphy could be done repeatedly for up to 1 week after a single tracer injection. The time interval between the injection and scintigraphic visualization of bleeding ranged from 10 min to 68 h, being longest in cases of occult bleeding. In most cases the scintigraphic findings were supported by other diagnostic modalities, including surgical removal of presumed sources of bleeding. In seven studies without scintigraphic signs of bleeding, a probable source of bleeding was identified by other means in one patient. The 111 In-platelet method seems to be a promising method for localization of gastrointestinal bleeding which may prove particularly useful in cases of occult or recurrent bleeding

  11. Scintigraphic instruments and techniques in nuclear medicine

    International Nuclear Information System (INIS)

    Bornand, B.; Soussaline, F.

    1977-03-01

    The development of new radiopharmaceuticals, cyclotron-produced radionuclides and improvement of detector, scanner and gamma camera characteristics have enable a remarkable recent progress in scintigraphic techniques for organ visualization and functional studies. Using a variety of techniques, positron cameras, section scanners, gamma holography, tomographic imaging appear to be playing an increasing important role. Data processing techniques, for example image processing and three dimensional reconstruction have significantly increased their impact. The principal research work and advances in technique achieved up to 1972 are summarized and the subjects which have been further exploited are outlined. The main section comprises references and abstracts of articles from scientific journals and conference proceedings (191 articles and 221 papers mentioned) for the period 1972-1975 to illustrate advances in this domain: Excerpta Medica (Nuclear Medicine) Abstract Journals and Nuclear Science Abstracts (1972-1975) were used as abstracting publications. This survey is completed with an index of authors and subject-matters. Eleven thesis are mentionned in an appendix [fr

  12. Histiocytosis X: Scintigraphic and roentgenological findings

    International Nuclear Information System (INIS)

    Fezoulidis, I.; Wickenhauser, J.; Schurawitzki, H.; Gritzmann, N.

    1987-01-01

    The aim of this study was to compare the roentgenological and scintigraphic osseous changes in 25 resp. 18 patients with histiocytosis X and to analyse them. In particular, it was also interesting to discuss the divergent reports in the literature in respect of scintigraphic storage behaviour. In all patients examined before initiation of therapy (39 osseous foci) high activities were found scintigraphically. The extension of the scintigraphically active zone was much greater than the corresponding translucencies on the X-ray film. On the other hand, patients after therapy still showed foci on the X-ray film whereas the scan had already become inactive. This striking discrepancy between scan findings before and after therapy could be one of the reasons for divergent literature reports on this problem. (orig.) [de

  13. Scintigraphic measurement of the contractile activity of the gastric antrum using factor analysis

    International Nuclear Information System (INIS)

    Bergmann, H.; Hoebart, J.; Kugi, A.; Stacher, G.; Granser, G.V.

    1990-01-01

    The motor activity of the gastric antrum is difficult to record by manometric means and scintigraphic methods have proved unsatisfactory so far as no consistent relationship between antral contractile activity and gastric emptying rate could be detected. We investigated, using data recorded in 16 healthy human subjects after the ingestion of a semisolid standard meal, whether a newly developed method employing factor analysis would yield more meaningful and reproducible results. Factor analysis was applied to sequential scintigraphic images (3-s frame time) of gastric antrum. The computed factor images and the respective factor curves are representative of distinct dynamic structures of the antrum. From the more or less sinusoidal excursions of the factor curves, which exhibited the 3 cycles per minute frequency characteristic for the stomach, amplitude, frequency and propagation velocity of antral contractions can be calculated. The amplitudes of the factor curves were used to calculate a contraction index. This contraction index was found to be correlated significantly negatively with the gastric half-emptying time of the ingested meal. The employed factor analytical approach thus seems a promising tool to further investigate the role of antral contractility in the process of gastric emptying. (Authors)

  14. Scintigraphic supervision of osteitis

    International Nuclear Information System (INIS)

    Manigault, L.; Sureau, B.; Wioland, M.; Perez, R.

    1975-01-01

    On the assumption that isotopic examinations of the bone metabolism and especially the scintigraphic method could give valuable results in the observation of osteitis patients treated with antibiotics, four cases of this disease were selected and followed regularly every three or four months for at least a year. Several bone scintigraphs were carried out with a scintillation camera after intraveinous injection of technetium-labelled pyrophosphate and the hyperfixation variations of the osteitis centre are given as a function of time. It is shown that bone scintigraphy gives an exact picture of the dimensions and morphology of lesions caused by an osteitis centre and above all, if repeated, enables the development of the infected region to be estimated. It seems that the healing of osteitis can be judged from scintigraphic evidence. Scintigraphy may be considered as a means to check the efficiency of an antibiotic treatment [fr

  15. Contribution to scintigraphic study of pulmonary ventilation using 133Xe

    International Nuclear Information System (INIS)

    Chareyron, R.P.

    1975-01-01

    A technique of regional lung function study, using 133 Xe, is described (instrumentation, procedure, results). A gamma-camera is used for this investigation, its main advantages are as follows. The picture is smaller than the one produced by a scanner, but is obtained more quickly. The gamma-camera equipped with a data processing unit is able to visualize areas of interest and to provide quantitative informations. Two parameters are studied. The first one is Xenon washout speed expressed in (ml/mn/cm 3 ) which gives an exact value of pulmonary ventilation. The latter is retention. This parameter is of interest because retention is more easy to evaluate than washout speed, and is able to quantify what is suggested by scintigraphic pictures. The technique has proven to be valuable in differentiating chronic bronchitis from post-bronchitic emphysema [fr

  16. Combined scintigraphic and radiographic diagnosis of bone and joint diseases. Including gamma correction interpretation. 4. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong-Whee [Sung Ae General Hospital, Seoul (Korea, Republic of). Dept. of Nuclear Medicine and Radiology

    2013-07-01

    In this fourth edition of Combined Scintigraphic and Radiographic Diagnosis of Bone and Joint Diseases, the text has been thoroughly amended, updated, and partially rearranged to reflect the latest advances. In addition to discussing the role of pinhole imaging in the range of disorders previously covered, the new edition pays detailed attention to the novel diagnostic use of gamma correction pinhole bone scan in a broad spectrum of skeletal disorders, including physical, traumatic, and sports injuries, infectious and non-infectious bone diseases, benign and malignant bone tumors, and soft tissue diseases. A large number of state of the art pinhole scans and corroborative CT, MRI, and/or ultrasound images are presented side by side. The book has been enlarged to encompass various new topics, including occult fractures; cervical sprain and whiplash trauma; bone marrow edema; microfractures of trabeculae; evident, gaping, and stress fractures; and differential diagnosis. This new edition will be essential reading for practitioners and researchers in not only nuclear medicine but also radiology, orthopedic surgery, and pathology.

  17. Combined scintigraphic and radiographic diagnosis of bone and joint diseases. Including gamma correction interpretation. 4. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Bahk, Yong-Whee

    2013-01-01

    In this fourth edition of Combined Scintigraphic and Radiographic Diagnosis of Bone and Joint Diseases, the text has been thoroughly amended, updated, and partially rearranged to reflect the latest advances. In addition to discussing the role of pinhole imaging in the range of disorders previously covered, the new edition pays detailed attention to the novel diagnostic use of gamma correction pinhole bone scan in a broad spectrum of skeletal disorders, including physical, traumatic, and sports injuries, infectious and non-infectious bone diseases, benign and malignant bone tumors, and soft tissue diseases. A large number of state of the art pinhole scans and corroborative CT, MRI, and/or ultrasound images are presented side by side. The book has been enlarged to encompass various new topics, including occult fractures; cervical sprain and whiplash trauma; bone marrow edema; microfractures of trabeculae; evident, gaping, and stress fractures; and differential diagnosis. This new edition will be essential reading for practitioners and researchers in not only nuclear medicine but also radiology, orthopedic surgery, and pathology.

  18. Scintigraphic ventriculography and stress testing

    International Nuclear Information System (INIS)

    Goris, M.L.; Hung, J.; Debusk, R.F.

    1982-01-01

    Scintigraphic stress ventriculography yields information which is complex and defies description by the difference in ejection fraction between rest and maximum exercise only. The complexity results in part from the ''derived'' nature of the ejection fraction measurement, which is physiologically secondary to stroke volume and end-diastolic volume. Furthermore, the nature of the stress test in which the pulse (stress) is not independent from the response forces an analysis which considers ''when'' as much as ''what'' happens. Automation in data processing, however, has made oversimplification unnecessary and allows a more exhaustive but correct analysis

  19. Scintigraphic evaluation of primary congenital hypothyroidism: results of the Greek screening program

    Energy Technology Data Exchange (ETDEWEB)

    Panoutsopoulos, G.; Ilias, I.; Batsakis, C.; Christakopoulou, I. [Dept. of Nuclear Medicine, ' ' Sotiria' ' Hospital, Athens (Greece); Mengreli, C. [Inst. of Child Health, Athens (Greece)

    2001-04-01

    The Greek screening program for primary congenital hypothyroidism was initiated in 1979. By early 2000, thyrotropin measurements had been performed in 1,976,719 newborns, using dried blood spots obtained by heel prick. Among these children, 584 were diagnosed with congenital hypothyroidism (incidence: 1/3,384 births) and were given L-thyroxine (L-T{sub 4}) replacement therapy. In order to further evaluate and classify the children as having either an aplastic (AT) or an ectopic thyroid gland (ET) or as showing thyroidal dyshormonogenesis (DN, with a nomotopic gland), scintigraphic studies were performed at the age of 2-3 years. In 413 children of this age group (including 24 subsequently diagnosed as having had transient hypothyroidism, in whom L-T{sub 4} therapy was not resumed), thyroid hormones were measured and scintigraphic studies were done after withdrawal of L-T{sub 4} replacement treatment for 3 weeks. Given the long duration of the study, we used various scintigraphic modalities. In 96 children (group A), scintigraphy was performed using technetium-99m pertechnetate ({sup 99m}TcO{sub 4}{sup -}; 18.5 MBq given i.v.) and a rectilinear scanner. Seventy-three children (group B) were studied with {sup 99m}TcO{sub 4}{sup -} (18.5 MBq given i.v.) and a gamma camera equipped with a pinhole collimator. In these groups, atropine was administered 30 min prior to the study (0.02 mg/kg i.v. or i.m.) in order to reduce the secretion of saliva from the salivary glands. Finally, in the remaining 220 children (group C) iodine-123 sodium iodide ({sup 123}I-Na) (0.74-1.85 MBq i.v.) and the same gamma camera were used. Between-group comparisons of scintigraphic findings were done with the chi square test. In 191 children from group C, thyroglobulin (Tg) was measured and in 49 children ultrasound (US) was performed (categorising the gland as AT or ET/DN). Comparison of these modalities was done with the kappa statistic. In group A, 61.5% of children had AT, 26.0% had ET and

  20. The value of scintigraphic examinations in the diagnosis of pathologic processes in the posterior scala in childhood and youth

    International Nuclear Information System (INIS)

    Piepgras, U.; Huber, G.; Emde, H.

    1980-01-01

    The diagnostical possibilities of computerized tomography (CT) and brain scintigraphy are compared. Serial scintigraphy by gamma cameras, scintigraphic examinations of the liquor space and the ventricles are discussed, too. In addition to CT, scintigraphy is also recommended in the following cases: hydrocephalus of unknown origin, dilatation of the IVth ventricle, diagnosis of recidive tumours, and unclear density differences. (L.E.)

  1. Scintigraphic diagnosis of the gastro-esophageal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Pfluecke, F.; Krueger, M.; Reinke, R.; Groth, P. (Rostock Univ. (German Democratic Republic). Radiologische Klinik)

    1982-09-01

    Patients with peptic esophagitis or typical complaints with respect to reflux without esophagitis and control persons (n = 68) were comparatively examined for gastroesophageal reflux by means of scintigraphy (after administration of test solutions labelled with /sup 99m/Tc-DTPA or after intravenous application of /sup 99m/Tc-pertechnetate) and by means of continuous intraesophageal p/sub H/ measurement. The scintigraphic test of the reflux was successful for very few patients only with reflux disease and a reflux detectable by measuring the p/sub H/. The application of pentagastrin failed in improving the scintigraphic detection of the reflux. The cause of the unsuccessful scintigraphic evidence for the majority of the reflux patients seems to be the relatively small reflux volume.

  2. Scintigraphic diagnosis of the gastro-esophageal reflux

    International Nuclear Information System (INIS)

    Pfluecke, F.; Krueger, M.; Reinke, R.; Groth, P.

    1982-01-01

    Patients with peptic esophagitis or typical complaints with respect to reflux without esophagitis and control persons (n = 68) were comparatively examined for gastroesophageal reflux by means of scintigraphy (after administration of test solutions labelled with /sup 99m/Tc-DTPA or after intravenous application of /sup 99m/Tc-pertechnetate) and by means of continuous intraesophageal p/sub H/ measurement. The scintigraphic test of the reflux was successful for very few patients only with reflux disease and a reflux detectable by measuring the p/sub H/. The application of pentagastrin failed in improving the scintigraphic detection of the reflux. The cause of the unsuccessful scintigraphic evidence for the majority of the reflux patients seems to be the relatively small reflux volume

  3. Scintigraphic determination of the effect of metoclopramide and morphine on small intestinal transit time

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, E.K.; Caride, V.J.; Winchenbach, K.; Troncale, F.J.; McCallum, R.W.

    1988-01-01

    To determine if a scintigraphic method could detect pharmacologic changes in small intestinal transit time (SITT), 10 male volunteers were studied at baseline and after intravenously administered metoclopramide (10 mg) and morphine (8 mg). Five of these volunteers were studied with the hydrogen breath test method for comparison. For each of the scintigraphic studies, the volunteers were positioned supine under a large-field-of-view gamma camera after ingesting an isosmotic lactulose solution containing 99mtechnetium-diethylenetriaminepentaacetic acid (DTPA). Data were collected and stored in a computer. Both gastric emptying and SITT were determined. SITT was 81 +/- 11 min (mean +/- S.E.M.; N = 10) during baseline studies, was decreased significantly to 50 +/- 6 min (N = 10; P less than 0.01) after metoclopramide, and was increased significantly to 161 +/- 15 min (N = 8; P less than 0.01) after morphine. Baseline mean values were 86.3 +/- 15 min (N = 15) for the hydrogen breath tests, 47 +/- 8 min (N = 5) for metoclopramide, and 183 +/- 16 min (N = 5) for morphine. For gastric emptying, there was no significant difference in percentage emptying at 1 hr for baseline and metochopramide (82 +/- 5% vs. 88 +/- 4%). Morphine prolonged gastric emptying at 1 hr to 63 +/- 8%. We conclude that the scintigraphic method for measuring SITT permits accurate investigation of the pharmacologic effects on intestinal motility and, in addition, may be a useful research and clinical method for SITT determination.

  4. Application of a general-purpose scintigraphic scanner to transverse-section (tomographic) gamma-ray imaging

    International Nuclear Information System (INIS)

    Bradstock, P.A.; Milward, R.C.

    1976-01-01

    The paper describes the recent application of a general-purpose commercial scintigraphic scanner to transverse-section radioisotope tomography. The principle of the method is to obtain the distribution of radioactive material in a thin transverse slice of the body or brain, from a mathematical reconstruction using the measured transverse projections of the activity within that slice. The usefulness of the radioisotope section-scanning technique for clinical diagnosis, as evidenced from one year's use of the machine at the Midland Centre for Neurology and Neurosurgery, Birmingham, U.K., is briefly discussed. (orig.) [de

  5. Thermosetting gels with modulated gelation temperature for ophthalmic use: the rheological and gamma scintigraphic studies.

    Science.gov (United States)

    Wei, Gang; Xu, Hui; Ding, Ping Tian; Li, San Ming; Zheng, Jun Min

    2002-09-18

    For ophthalmic drug delivery, Pluronic F127 solutions have a phase transition temperature too low for them to be instilled into the eye at room temperature. Refrigerator storage is usually required to make administration easier, whereas the potential irritation of cold to the sensitive ocular tissues may result in poor topical bioavailability. The purpose of this study is to develop a thermosetting gel with a suitable phase transition temperature by combining Pluronic analogs and to examine the influence of incorporating mucoadhesive polysaccharide, sodium hyaluronate (HA-Na), on the ocular retention of the gel. Dynamic rheological method and single photon emission computing tomography (SPECT) technique were used to ex/in vivo evaluate the thermosetting gels, respectively. An optimized formulation containing 21% F127 and 10% F68 increased the phase transition temperature by 9 degrees C as evaluated by elasticity modulus compared to that of individual 21% F127 solution. Rheological behaviors of the Pluronic solutions showed that the combined Pluronic formulation was free flowing liquid below 25 degrees C and converted to a firm gel under the physiological condition. Furthermore, this formulation possessed the highest viscosity both before and after tear dilution at 35 degrees C. Gamma scintigraphic data demonstrated that the clearance of the thermosetting gel labeled with 99mTc-DTPA was significantly delayed with respect to the phosphate buffered solution, and at least a threefold increase of the corneal residence time was achieved. However, no further improvement in the ocular retention was observed when adding HA-Na into the thermosetting gel due to the substantially decreased gel strength. Copyright 2002 Elsevier Science B.V.

  6. Scintigraphic appearance of the piriformis muscle syndrome

    International Nuclear Information System (INIS)

    Karl, R.D. Jr.; Yedinak, M.A.; Hartshorne, M.F.; Cawthon, M.A.; Bauman, J.M.; Howard, W.H.; Bunker, S.R.

    1985-01-01

    This is the first report in the nuclear medicine literature of the scintigraphic appearance of the piriformis muscle syndrome. This syndrome previously has been thought to be a purely clinical diagnosis and imaging modalities have been ignored. However, its confusing clinical presentation can lead to unnecessary surgical exploration. This case is presented to illustrate the characteristic scintigraphic pattern and suggest the role of nuclear medicine scanning in establishing the diagnosis

  7. Scintigraphic features of cirrhosis of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Bell, E; Biersack, H J; Altland, H; Albrecht, M; Winkler, C

    1980-09-01

    A retrospective study of 101 patients with histologically confirmed cirrhosis of the liver and portal hypertension was carried out in order to evaluate the accepted scintigraphic criteria. In only 20% were all the essential criteria present. The absence of generally accepted important scintigraphic signs does not exclude the diagnosis of cirrhosis of the liver. Specificity of liver scintigraphy in cirrhosis of the liver is fairly low, but sensitivity of the method is almost 100%.

  8. Scintigraphic evaluation of the sacroiliac joints in anklylosing spondylitis

    International Nuclear Information System (INIS)

    Schoerner, W.

    1980-01-01

    The sedimentation of sup(99m)Tc-phosphate complexes into the sacroiliac joints was investigated in 94 patients with loin pains and suspected of ankylosing spondylitis (SpA) and a control group of 96 healthy patients. The investigation yields the following results: 1. the visual evaluation of the scintigrams does not allow a reliable diagnosis and should be replaced by a semi-quantitative technique, 2. the index ISC/sacrum does remarkably depend on age, 3rd even in young patients the scintigraphic examination appears to be useful to alidate the clinical suspicion of sacroilictis which is in contradiction to literature, 4th with increasing SpA the scintigraphic detectability of changes in the ISG decreases. 5th the floriditily of the ISG process determines the scintigraphic detectability of the process of the disease, 6th the scintigraphic finding is unspecific. Inflammatory states of the disease of different genesis and degenerative processes in the ISG equally yield pathological index values. (orig./MG) [de

  9. Pharyngeal transit time measured by scintigraphic and biomagnetic method

    International Nuclear Information System (INIS)

    Miquelin, C.A.; Braga, F.J.H.N.; Baffa, O.

    1996-01-01

    A comparative evaluation between scintigraphic and biomagnetic method to measure the pharyngeal transit is presented. Three volunteers have been studied. The aliment (yogurt) was labeled with 9 9 m Technetium for the scintigraphic test and with ferrite for the biomagnetic one. The preliminary results indicate a difference between the values obtained, probably due to the biomagnetic detector resolution

  10. Scintigraphic demonstration of splenosis

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, C.A.; Sakimura, I.T.; Siegel, M.E.

    1986-03-01

    A case of splenosis, or the autotransplantation of splenic tissue following trauma, was encountered unexpectedly on a routine liver scan performed in the workup of alcoholic liver disease. Confirmatory scintigraphic images using Tc-99m labeled, heat-damaged, autologous erythrocytes are presented with CT scans of the abdomen.

  11. Quantitative and regional evaluation methods for lung scintigraphs

    International Nuclear Information System (INIS)

    Fichter, J.

    1982-01-01

    For the evaluation of perfusion lung scintigraphs with regard to the quantitative valuation and also with regard to the choice of the regions new criteria were presented. In addition to the usual methods of sectioning each lung lobe into upper, middle and lower level and the determination of the per cent activity share of the total activity the following values were established: the median of the activity distribution and the differences of the per cent counting rate as well as of the median of the corresponding regions of the right and left lung. The individual regions should describe the functional structures (lobe and segment structure). A corresponding computer program takes over the projection of lobe and segment regions in a simplified form onto the scintigraph with consideration of individual lung stretching. With the help of a clinical study on 60 patients and 18 control persons with 99mTc-MAA and 133 Xe-gas lung scintigraphs the following results could be determined: depending on the combination of the 32 parameters available for evaluation and the choice of regions between 4 and 20 of the 60 patients were falsely negatively classified and 1 to 2 of the 18 controls were falsely positive. The accuracy of the Tc-scintigraph proved to be better. All together using the best possible parameter combinations comparative results were attained. (TRV) [de

  12. Diffuse lung uptake (DLU) on Ga-67 scintigraph: Clinical, radiologic and pathologic correlation

    International Nuclear Information System (INIS)

    Sy, W.M.; Seo, I.S.; Vieira, J.; Zaman, M.

    1985-01-01

    Review, analysis and correlation (clinical, radiologic and pathologic) of 29 consecutive adults (16 drug addicts and/or homosexuals) with DLU on Ga-67 scintigraph were made. Diffuse increased uptake of at least 75% of both lungs was considered as DLU. WFOF cameras were used to obtain 24 to 96 hr. scintigraphs after IV injection of 3-5 mCi of Ga-67 citrate. In 26, tissue diagnosis established: pneumocystis carinii (PC) 15, miliary tuberculosis (TB) 3, sarcoidosis (SR) 3, drug-induced toxicity 2, and toxoplasmosis (TX), primary hyperparathyroidism and nonspecific lymphocytic pneumonia-one each. In two with breast and one with esophageal carcinomas, no lung tissue diagnosis was sought. Concurrent chest x-rays were negative in 16, but in 7/16, lung infiltrate was later documented. An average of 31 days elapsed before x-rays became positive in four with PC, 7 days in two with TB, and 22 days in one with TX. In 13, concurrent x-rays showed lung infiltrate, but in 6, only subtle, localized rather than diffuse infiltrate was noted. Fourteen of 29 had at least two Ga-67 studies. In 12 (7 PC, 2 TB, 3 SR) of 14 whose repeat studies showed significant to total disappearance of DLU, all did well clinically. In two whose initial studies were negative or equivocal, they became clinically worse when the repeat study showed DLU. In three others (2 PC, 1 TX) who died, their single studies recorded intense DLU. DLU on gallium scintigraph indicated a variety of pathology. In 55.2%, gallium scintigraph predated x-ray findings by a few days to weeks. In 20.3%, x-ray findings were only subtle or localized. Scintigraphic changes correlated well with the clinical courses in various diseases

  13. The new techniques of scintigraphic imaging

    International Nuclear Information System (INIS)

    Chatal, J.F.

    1990-01-01

    The purpose of scintigraphic imaging is not to explore the morphology of an organ (or its abnormalities) but rather its functional and metabolic characteristics. It is thus important that a molecular structure (e.g., a hormonal receptor or an antigen) closely linked to the functional activity of an organ or tissue be targeted on its cell surface. Such diagnostic targeting requires the synthesis and labeling of a radiopharmaceutical substance specific for the receptor or antigen in question. It also requires a detection system adapted to count rates and signal-to-background ratios (generally moderate). The synthesis of new radiopharmaceutical agents, a critical stage for the future of nuclear medicine, is a long and often risky process in which success is difficult to foresee. Radiolabeling must be stable in vitro and in vivo, and the radiopharmaceutical must subsequently retain its capability of recognizing the targeted molecule. In endocrinology, the exemplary achievement in this direction has been the synthesis of 131 I-6-iodomethylnorcholesterol and 131 I-metaiodobenzylguanidine for functional scintigraphy of the adrenal cortex and medulla. Progress in detection equipment has been marked by the development of monophotonic tomoscintigraphy, using gamma cameras with a revolving head to obtain slices in different spatial planes showing the distribution in the organism of the injected radiopharmaceutical agent [fr

  14. Scintigraphic Small Intestinal Transit Time and Defaecography in Patients with J-Pouch

    Directory of Open Access Journals (Sweden)

    Mie Dilling Kjaer

    2015-10-01

    Full Text Available Objective methods for examination of pouch function are warranted for a better understanding of the functional result and treatment of dysfunction. The objective of this study was to evaluate the results of scintigraphic intestinal transit time and defaecography compared to the results of pouch function, mucosal condition and a questionnaire on quality of life (QoL. This cross-sectional study included 21 patients. Scintigraphic transit time and defaecography was determined with the use of Tc-99m. Pouch function was assessed by number of bowel movements, pouch volume, and continence. Pouch mucosal condition was evaluated by endoscopy and histology. Median transit time was 189 min (105–365. Median ejection fraction at defaecography (EF was 49% (3–77 and 62% (17–98 after first and second defecation. Median pouch volume was 223 mL (100–360. A median daily stool frequency of nine (4–25 was reported and three (14% patients suffered from daytime incontinence. No patients had symptomatic or endoscopic pouchitis; however, the histology showed unspecific inflammation in 19 (90% patients. There was no correlation between transit time, evacuation fraction (EF and pouch function in univariate analysis. However, we found a high body mass index (BMI and a low bowel movement frequency to be associated with a longer transit time by multivariate analysis. Scintigraphic determination of transit time and defaecography are feasible methods in patients with ileal pouch anal anastomosis, but the clinical relevance is yet doubtful.

  15. Gastroesophageal reflux disease. Scintigraphic, endoscopic and histologic considerations

    Energy Technology Data Exchange (ETDEWEB)

    Kault, B.; Halvorsen, T.; Petersen, H.; Grette, K.; Myrvold, H.E.

    1986-01-01

    Radionucleotide scintigraphy and esophagoscopy with biopsy were carried out in 101 patients with symptoms strongly suggestive of gastroesophageal reflux (GER) disease. GER was visualized by scintigraphy in 86.1% of the patients. Endoscopic and histologic esophagitis were found in 68.1% and 58.4% of the patients, respectively, whereas both examinations taken together showed evidence of esophagitis in 82%. Histologic evidence of esophagitis was found in nearly all patients with severe endoscopic changes, and in 43.7% of the patients with no endoscopic abnormality. Scintigraphic reflux was demonstrated more frequently in the patients with severe endoscopic esophagitis (97.5%) than in those with no or only mild endoscopic changes (78.6%). Scintigraphic reflux was found in 91.5% and 78.5% of the patients with and without histologic evidence of esophagitis. 15 of the 18 patients (83.3%) without endoscopic and histologic abnormalities in the esophagus had scintigraphic evidence of reflux. The present study strongly supports the clinical significance of scintigraphy in GER disease and confirms that esophageal biopsy specimens increase the sensitivity of endoscopic evaluation. 31 refs.

  16. Scintigraphic presentation of hip joint synovial chondromatosis

    Energy Technology Data Exchange (ETDEWEB)

    Zwas, S T; Friedman, B; Nerubay, J

    1988-09-01

    A case of hip joint synovial chondromatosis with an unusual scintigraphic pattern is described. This pattern was suggestive of a hip joint destructive reactive articular process or late manifestations of avascular necrosis of the femoral head. Concurrent radiographs were normal, as were laboratory investigations. Follow-up radiographs six months later showed radiolucencies and erosive bone changes in the diseased joint. Surgical and histopathological findings revealed well developed hip synovial chondromatosis (HSC) with thickened synovium and large, loose, cartilaginous bodies occupying and widening the tightened joint space, with destructive secondary juxta articular pressure and bone erosions. This and other scintigraphic patterns in HSC, and the differential diagnosis of the findings in patients with painful hip presentations are discussed.

  17. Analysis of stress fractures associated with lameness in Thoroughbred flat racehorses training on different track surfaces undergoing nuclear scintigraphic examination.

    Science.gov (United States)

    MacKinnon, M C; Bonder, D; Boston, R C; Ross, M W

    2015-05-01

    There is limited information regarding the impact of training track surface on the occurrence of stress fractures. To evaluate the impact of training track surface on the proportion of long bone and pelvic stress fractures associated with lameness in Thoroughbred horses in flat race training undergoing nuclear scintigraphic examination. Retrospective study. Scintigraphic examinations of Thoroughbred flat racehorses were evaluated from 2 hospitals (hospital A [Toronto Equine Hospital], 2003-2009, and hospital B [George D. Widener Hospital for Large Animals, School of Veterinary Medicine, University of Pennsylvania], 1994-2006). Horses admitted to hospital A trained at a single track, at which the main training surface changed from dirt to synthetic on 27 August 2006. Two distinct populations existed at hospital B: horses that trained on dirt (numerous trainers) and those that trained on turf (single trainer). All scintigraphic images were evaluated by a blinded reviewer. Fisher's exact test and logistic regression were used when appropriate, and significance was set at Pfractures detected in scintigraphic examinations from horses training on a synthetic surface (31.7%) in comparison to scintigraphic examinations from horses training on a dirt surface (23.0%) at an earlier point in time (P = 0.03). There was a greater proportion of hindlimb/pelvic and tibial stress fractures diagnosed in horses from the synthetic surface-trained group than from the dirt-trained group at hospital A (Pfractures diagnosed, but other factors, such as training philosophy, appear to be important. Future prospective investigations to fully elucidate the relationship between training track surface and the proportion of stress fractures and other nonfatal musculoskeletal injuries are warranted. © 2014 EVJ Ltd.

  18. Scintigraphic aspect of liver in hepatitis. [/sup 198/Au-radiocolloid

    Energy Technology Data Exchange (ETDEWEB)

    Silva, W M; Medeiros, M [Hospital dos Servidores do Estado, Rio de Janeiro (Brazil). Servico de Medicina Nuclear

    1976-01-01

    A series of scintigraphs was made in a group of 15 patients with viral hepatitis, and compared with biochemical tests. Although in some patients the last biochemical tests were only slightly elevated, and in others entirely normal, they all continued to show abnormal scintigraphs with a mottled aspect and splenic uptake. It is supposed that some sequellae remain in the hepatic tissue even though the patient responds well in clinical and laboratory tests.

  19. Scintigraphic evaluation of gastrointestinal motility disorders

    Energy Technology Data Exchange (ETDEWEB)

    Choe, Jae Gol [College of Medicine, Korea Univ., Seoul (Korea, Republic of)

    2001-02-01

    Current scintigraphic tests of gastrointestinal motor function provides relevant pathophysiologic information, but their clinical utility is controversial. Many scintigraphic methods are developed to investigate gastrointestinal motility from oral cavity to colon. These are esophageal transit scintigraphy, oropharyngeal transit study, gastric emptying test, small bowel transit time measurement, colon transit study and gastroesopahgeal reflux scintigraphy. Scintigraphy of gastrointestinal tract is the most physiologic and noninvasive method to evaluate gastrointestinal motility disorders. Stomach emptying test is regarded as a gold standard in motility study. Gastrointestinal transit scintigraphy also has a certain role in assessment of drug effect to GI motility and changes after theraphy of motility disorders. Scintigraphy provides noninvasive and quantitative assessment of physiological transit throughout the gastrointestinal tract, and it is extremely useful for diagnosing gastrointestinal motor dysfunction. This article reviews the current procedures, indications, significance and guidelines for gastrointestinal motility measurements by scintigraphy.

  20. Scintigraphic evaluation of gastrointestinal motility disorders

    International Nuclear Information System (INIS)

    Choe, Jae Gol

    2001-01-01

    Current scintigraphic tests of gastrointestinal motor function provides relevant pathophysiologic information, but their clinical utility is controversial. Many scintigraphic methods are developed to investigate gastrointestinal motility from oral cavity to colon. These are esophageal transit scintigraphy, oropharyngeal transit study, gastric emptying test, small bowel transit time measurement, colon transit study and gastroesopahgeal reflux scintigraphy. Scintigraphy of gastrointestinal tract is the most physiologic and noninvasive method to evaluate gastrointestinal motility disorders. Stomach emptying test is regarded as a gold standard in motility study. Gastrointestinal transit scintigraphy also has a certain role in assessment of drug effect to GI motility and changes after theraphy of motility disorders. Scintigraphy provides noninvasive and quantitative assessment of physiological transit throughout the gastrointestinal tract, and it is extremely useful for diagnosing gastrointestinal motor dysfunction. This article reviews the current procedures, indications, significance and guidelines for gastrointestinal motility measurements by scintigraphy

  1. NEPHRUS: model of intelligent multilayers expert system for evaluation of the renal system based on scintigraphic images analysis

    International Nuclear Information System (INIS)

    Silva, Jose W.E. da; Schirru, Roberto; Boasquevisque, Edson M.

    1997-01-01

    This work develops a prototype for the system model based on Artificial Intelligence devices able to perform functions related to scintigraphic image analysis of the urinary system. Criteria used by medical experts for analysis images obtained with 99m Tc+DTPA and/or 99m Tc+DMSA were modeled and a multi resolution diagnosis technique was implemented. Special attention was given to the programs user interface design. Human Factor Engineering techniques were considered so as to ally friendliness and robustness. Results obtained using Artificial Neural Networks for the qualitative image analysis and the knowledge model constructed shows the feasibility of Artificial Intelligence implementation that use 'inherent' abilities of each technique in the resolution of diagnosis image analysis problems. (author). 12 refs., 2 figs., 2 tabs

  2. Congenital vascular malformations in scintigraphic evaluation

    International Nuclear Information System (INIS)

    Pilecki, Stanisław; Gierach, Marcin; Gierach, Joanna; Świętaszczyk, Cyprian; Junik, Roman; Lasek, Władysław

    2014-01-01

    Congenital vascular malformations are tumour-like, non-neoplastic lesions caused by disorders of vascular tissue morphogenesis. They are characterised by a normal cell replacement cycle throughout all growth phases and do not undergo spontaneous involution. Here we present a scintigraphic image of familial congenital vascular malformations in two sisters. A 17-years-old young woman with a history of multiple hospitalisations for foci of vascular anomalies appearing progressively in the upper and lower right limbs, chest wall and spleen. A Parkes Weber syndrome was diagnosed based on the clinical picture. Due to the occurrence of new foci of malformations, a whole-body scintigraphic examination was performed. A 12-years-old girl reported a lump in the right lower limb present for approximately 2 years, which was clinically identified as a vascular lesion in the area of calcaneus and talus. Phleboscintigraphy visualized normal radiomarker outflow from the feet via the deep venous system, also observed in the superficial venous system once the tourniquets were released. In static and whole-body examinations vascular malformations were visualised in the area of the medial cuneiform, navicular and talus bones of the left foot, as well as in the projection of right calcaneus and above the right talocrural joint. People with undiagnosed disorders related to the presence of vascular malformations should undergo periodic follow-up to identify lesions that may be the cause of potentially serious complications and to assess the results of treatment. Presented scintigraphic methods may be used for both diagnosing and monitoring of disease progression

  3. Scintigraphic evaluation of floating, gastroretentive formulation of clarithramycin in healthy human volunteers

    International Nuclear Information System (INIS)

    Ali, Raisuddin; Aji Alex, M.R.; Dutta, M.; Singh, Thakuri; Bhatnagar, A.; Bajaj, M.; Singla, Y.P.; Ahmad, F.J.; Khar, R.K.

    2010-01-01

    Full text: Objective of the present study concerns formulation and evaluation of oral buoyant effervescent tablets of clarithromycin for prolongation of gastric residence time (GRT) and to enhance eradication of Helicobacter pylori (H. pylori) for longer period of time. Materials and Methods: Clarithromycin (CLA) a macrolide antibiotic was chosen as the candidate drug for its immense potential as an Anti H. pylori agent. HPMC and/or xanthan gum were used as release-retarding polymer(s) whereas sodium bicarbonate (NaHCO 3 ) was utilized as a gas former. The tablets were prepared by wet granulation method. Formulations were evaluated for physicochemical properties, in vitro drug release as well as drug release kinetics and stability studies. In vivo gamma scintigraphic studies were assessed for the optimized buoyant gastroretentive tablets in six healthy human volunteers to study influence of nature of the dosage form i.e. conventional or sustained release gastroretentive tablets and the presence of food in the stomach on intragastric performance of gastroretentive tablets. Result: The fabricated tablets showed acceptable physiochemical properties. Non-fickian release transport was confirmed as the drug release mechanism from the prepared tablets. Optimized tablets composed of HPMC K15M, xanthan gum, and NaHCO 3 were promising systems exhibiting excellent floating properties. The overall performance was found to be highly sustained. Scintigraphic imaging revealed GRT of 320 min or more in fed state on the other hand GRT of 180 min or less in case of unfed state. Conclusion: The developed gastroretentive system has potential to increase efficacy of the therapy and improve patient

  4. Scintigraphic measurement of colonic transit in patients with idiopathic constipation

    International Nuclear Information System (INIS)

    Yoon, K. H.; Kim, C. K.

    1999-01-01

    To evaluate usefulness of scintigraphic measurement of total and regional colonic transit in patients with idiopathic constipation. 25 patients who were complained chronic constipation underwent scintigraphic measurement of the total and regional colon transit. Of them 10 patients were diagnosed as idiopathic constipation, none of whom had evidence of abnormal function of the pelvic floor. Ten healthy volunteers were also studied. 67 Gallium-labelled Amberlite resin particles were ingested in a coated capsule with methacrylate that dispersed in the ileocecal region. Images were obtained using a gamma camera at regular intervals for the 2, 4, 8, 24, and 48 hours after the initial counting of the radioactivity in the cecum. We determined the geometric center in four regions of interest in the colon (ascending, transverse, descending, and rectosigmoid). Ten patients with colonic inertia showed significant retention of solid residue in the ascending and transverse colon over a 48-hour period. The median values for the healthy subjects at 2, 4, 8, and 24, and 48 hours were 1.44±0.2 (midway through ascending), 1.71±0.45 (midway through transverse), 2.64±0.95 (midway through descending), 3.94±0.89 (midway through rectosigmoid), and 4.52±0.76 (midway through the stool compartment). On the contrary, the values of ten patients with colonic inertia were 1.0±0.0 (midway through ascending), 1.0±0.0 (midway through ascending). 1.02 ±0.06 (midway through ascending), 1.70±0.36 (midway through transverse), and 2.33±0.31(midway through descending) at the same time (p<0.001). In patients with idiopathic constipation is characterized by exaggerated reservoir factions of the ascending and transverse colons. Scintigraphy using 67 Gallium-labelled pellets seems to be a useful tool to demonstrate the delayed colonic transit in patients with colonic inertia

  5. Scintigraphic measurement of colonic transit in patients with idiopathic constipation

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K. H.; Kim, C. K. [College of Medicine, Wonkwang Univ., Iksan (Korea, Republic of)

    1999-07-01

    To evaluate usefulness of scintigraphic measurement of total and regional colonic transit in patients with idiopathic constipation. 25 patients who were complained chronic constipation underwent scintigraphic measurement of the total and regional colon transit. Of them 10 patients were diagnosed as idiopathic constipation, none of whom had evidence of abnormal function of the pelvic floor. Ten healthy volunteers were also studied. 67 Gallium-labelled Amberlite resin particles were ingested in a coated capsule with methacrylate that dispersed in the ileocecal region. Images were obtained using a gamma camera at regular intervals for the 2, 4, 8, 24, and 48 hours after the initial counting of the radioactivity in the cecum. We determined the geometric center in four regions of interest in the colon (ascending, transverse, descending, and rectosigmoid). Ten patients with colonic inertia showed significant retention of solid residue in the ascending and transverse colon over a 48-hour period. The median values for the healthy subjects at 2, 4, 8, and 24, and 48 hours were 1.44{+-}0.2 (midway through ascending), 1.71{+-}0.45 (midway through transverse), 2.64{+-}0.95 (midway through descending), 3.94{+-}0.89 (midway through rectosigmoid), and 4.52{+-}0.76 (midway through the stool compartment). On the contrary, the values of ten patients with colonic inertia were 1.0{+-}0.0 (midway through ascending), 1.0{+-}0.0 (midway through ascending). 1.02 {+-}0.06 (midway through ascending), 1.70{+-}0.36 (midway through transverse), and 2.33{+-}0.31(midway through descending) at the same time (p<0.001). In patients with idiopathic constipation is characterized by exaggerated reservoir factions of the ascending and transverse colons. Scintigraphy using 67 Gallium-labelled pellets seems to be a useful tool to demonstrate the delayed colonic transit in patients with colonic inertia.

  6. Gallium 67 scintigraphic examination of dilated myocardiopathies

    International Nuclear Information System (INIS)

    Lanfranchi, J.; Sachs, R.N.; Beaudet, B.; Deblock, C.; Tellier, P.

    1989-01-01

    Twenty-seven patients were diagnosed as having dilated cardiomyopathies, based on increases in the cardiothoracic index > 0.50, in the diastolic and systolic diameters of the left ventricle, and in the telediastolic volume of the left ventricle, which was indexed by body surface determined by contrast ventriculography. They underwent gallium 67 scintigraphic examination of the myocardium, in order to non-invasively detect the presence of an inflammatory infiltrate. Fifteen of them also had endomyocardial biopsies and all had virology check-up. The results were disappointing. Only in one case was the scintigraphic image undeniably positive; in 20 other patients the findings were dubious or negative. This technique did not demonstrate the presence of an inflammatory infiltrate and thus an association between myocarditis and dilated cardiomyopathy, could not be established [fr

  7. Scintigraphic and clinical findings in the Standardbred metatarsophalangeal joint: 114 cases (1993-1995)

    International Nuclear Information System (INIS)

    Ross, M.W.

    1998-01-01

    To correlate scintigraphic and clinical findings of the metatarsophalangeal joint (MTPJ) in Standardbreds, radiographic findings in horses with confirmed MTPJ lameness, and determine if stress reaction and more advanced bone remodelling occurred in the MTPJ, medical records of 114 Standardbreds admitted between September 1993 and April 1995 in which bone scintigraphy included standing lateral and plantar views of the metatarsophalangeal joint (MTPJ) were reviewed. Images obtained using a large field of view gamma camera were evaluated visually for location, definition and intensity of increased radioisotope uptake (IRU), which was graded as mild, moderate, or intense. Clinical history and lameness examination findings were recorded and, in horses with documented MTPJ lameness, radiographic examination included the 30 degree (down-angled) dorsolateral 45 degree plantaromedial view thought to be useful in evaluation of the plantarolateral condyle of the third metatarsal bone (MtIII). The most common abnormality, IRU of the plantarolateral aspect of MtIII, was seen in 67 horses, and horses were further classified according to scintigraphic and clinical findings. In 43 horses in which lameness was not localised to the MTPJ, mild (32 horses), moderate (10 horses), and intense (one horse) IRU of MtHII was found. In 24 horses with lameness localised to the MTPJ, moderate (18 horses) and intense (6 horses) IRU was found. Of 18 horses with moderate IRU of MtIII, 9 had radiographic evidence of abnormal bony remodelling of MtIII, whereas 5 of 6 horses with intense IRU had radiographic changes. In 12 horses with MTPJ lameness and radiographic evidence of bony remodelling without fracture, radiographic changes consisted of plantarolateral subchondral radiolucency and sclerosis (7 horses), radiolucency and osteochondrosis (one horse), and plantar MtIII sclerosis without radiolucency (4 horses). In 2 horses with moderate IRU and MTPJ lameness, radiographic evidence of

  8. Scintigraphic acquisition entropy (2). A new approach in the quality control of the scintillation camera performances

    International Nuclear Information System (INIS)

    Elloumi, I.; Bouhdima, M.S.

    2002-01-01

    A new approach in the survey of the performances of gamma camera based on the entropy associated to the scintigraphic acquisition is presented. We take into account the sensitivity, the variation of the collimator response in function of the depth, the uncertainty on the number of counts, the multiplex effect and the spatial uncertainty. This entropy function is expressed in function of all the acquisition parameters: intrinsic crystal resolution, collimator characteristics, emitter object parameters and the source activity. The application of this method to the study of the influence of the collimation shows that the entropy associated to a collimator permits a best appreciation of the quality of the acquisition and therefore a better analysis of collimator performances. Likewise, the evolution of the entropy associated to the acquisition of a uniform source image is in agreement with the variation of the quality of image histogram. One shows, thus, that nor the spatial resolution, nor the sensitivity and nor the signal to noise ratio are able detect a variation of the image quality, when analysed one by one. (author)

  9. Scintigraphic evaluation of the esophageal-gastric function

    International Nuclear Information System (INIS)

    Taillefer, R.; Lefebvre, B.; Beauchamp, G.

    1986-01-01

    The authors present a brief review of the use of radionuclides in the pathophysiological evaluation of both esophageal and gastric function. Technical indications of these three following scintigraphic procedures are discussed: radionuclide esophagogram; gastro-esophogeal reflux study; and gastric emptying study

  10. Scintigraphic follow-up of fracture healing in animals

    International Nuclear Information System (INIS)

    Klug, W.; Franke, W.G.; Schulze, M.

    1983-01-01

    Secondary bone fracture heating was analysed by scintigraphic follow-up studies in rabbits using sup(99m)Tc-HEDP. 24 hours after fracture the activity ratio between the fractured and the non-fractured lower limb was 2,2. The maximal count density in the fracture region is found during the 14th and 28th day after fracture. Concomitantly there is a significant increase of bone marrow vessels and content of copper, magnesium, sodium and water in the callus. Although roentgenographic controls and static investigations with respect to consolidation reveal a complete heating already 126 days after fracture, the complete scintigraphic normalisation of the lower limb fracture of the rabbit is found not earlier than at the 203rd day after fracture. (orig.) [de

  11. Scintigraphic follow-up of fracture healing in animals

    Energy Technology Data Exchange (ETDEWEB)

    Klug, W.; Franke, W.G.; Schulze, M.

    1983-08-01

    Secondary bone fracture healing was analysed by scintigraphic follow-up studies in rabbits using sup(99m)Tc-HEDP. 24 hours after fracture the activity ratio between the fractured and the non-fractured lower limb was 2,2. The maximal count density in the fracture region is found during the 14th and 28th day after fracture. Concomitantly there is a significant increase of bone marrow vessels and content of copper, magnesium, sodium and water in the callus. Although roentgenographic controls and static investigations with respect to consolidation reveal a complete healing already 126 days after fracture, the complete scintigraphic normalisation of the lower limb fracture of the rabbit is found not earlier than at the 203rd day after fracture.

  12. Scintigraphic imaging with 99mTc- exorphin C in rabbits

    International Nuclear Information System (INIS)

    Ertay, T.; Uenak, P.; Tasci, C.; Zihnioglu, F.; Durak, H.

    2005-01-01

    Exorphin C is a peptide with five amino acids [(Tyr-Pro-Ile-Ser-Leu) Trifluoroacetate salt] (Sigma) that has an affinity to opioid receptor-expressing tissues and tumors. Exorphin-C was labeled with 99m Tc using glucoheptonate (GH) as bifunctional chelating agent. Then, we investigated its radiopharmaceutical potential as opioid receptor-expressing tissue on rabbits. Quality controls were performed by ITLC, paper electrophoresis and HPLC. Labeling efficiency was higher than 98%. The compound was stable for at least 5 h at room temperature. Scintigraphic imaging with 99m Tc-GH-exorphin C ( 99m Tc-GE) was performed on male Albino rabbits. Static images were obtained from anterior projection using a Camstar XR/T gamma camera at several time intervals. Although a significant amount of activity was seen in the brain, less activity was seen on receptor saturation studies at 30 min. Slight hepatobiliary excretion was seen, though the main excretion route was renal. After saturating, the receptor hepatobiliary excretion was not seen; the only excretion route was renal

  13. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    in the experiment. Evaluation of one versus two scintigraphic projections, trials for assessment of the reproducibility, a comparison of the scintigraphic method with a water-plethysmographic method and registration of the fractional reduction in blood volume caused by exsanguination as a result of simple elevation......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation......We introduce a new method for evaluating reductions in local blood volumes in extremities, based on the combined use of autologue injection of 99mTc-radiolabelled erythrocytes and clamping of the limb blood flow by the use of a tourniquet. Twenty-two healthy male volunteers participated...

  14. Scintigraphic appearances of Gaucher's disease

    International Nuclear Information System (INIS)

    Okada, Junichi; Uchiyama, Guio; Hayakawa, Kazushige; Araki, Tsutomu; Hayashi, Sanshin; Yamada, Kayoko; Seto, Kazuhiko

    1985-01-01

    Gaucher's disease is an inborn error of metabolism in which glucocerebroside accumlates within reticuloendotherial cells of spleen, liver and bone marrow. The scintigraphic appearances are described in a 19-year-old man with Gaucher's disease. The colloid scan showed increased uptake in the lung and bone marrow of legs where the reticuloendotherial system was activated. The bone scan demonstrated increased activity in the metaphyseal and diaphyseal region infiltrated by Gaucher's cell. Ga-67 was thought to be accumlated in the progressive focus of the disease. (author)

  15. Radiographic and scintigraphic evaluation of total knee arthroplasty

    International Nuclear Information System (INIS)

    Schneider, R.; Soudry, M.

    1986-01-01

    Various radiographic and scintigraphic methods are used to supplement clinical findings in the evaluation of total knee arthroplasty and its complications. Serial roentgenograms offer reliable information for diagnosing mechanical loosening. Wide and extensive radiolucency at the cement-bone interface and shift in position and alignment of prosthetic components can be seen in almost all cases by the time revision is necessary. Radiographic abnormalities are usually not present in acute infection, but are often present in chronic infection. Bone scanning has a high sensitivity for diagnosis of infection or loosening, but is nonspecific because increased uptake is often present around asymptomatic total knee arthroplasties with normal radiographs. Differential bone and Gallium scanning and scanning with Indium 111-labeled leukocytes have a greater specificity for diagnosis of infection than does bone or Gallium scanning alone. Routine radiographic and scintigraphic studies have shown a high incidence of deep vein thrombosis in the calf after total knee arthroplasty. Clinically significant pulmonary embolization is infrequent

  16. Economic analysis of radiodiagnostic equipment use

    International Nuclear Information System (INIS)

    Kochetova, G.P.; Turaev, R.N.

    1984-01-01

    The method for calculating costs for performing radiotdiagnostic investigation is suggested, analysis of structure of these costs and their dependence on output and working in shifts is given. As example the calculation of costs for performing radiodiagnostic investigations on gamma cameras with a computer and without it and on a scanner using fabricated radiopharmaceuticals and short-lived radionuclides. The developed technique for costs calculation for radiodignostic investigation permits to determine the cost of performing any investigation in changing values of any cost components. The analysis of the cost stucture for the investigation and dependence on apparatus capacity permit to contemplate the methods of reducing costs and raising apparatus use efficiency. One of these methods is transition to double-shift work of scintigraphic rooms equipped in the first place by gamma-cameras with computers

  17. Scintigraphic demonstration of tracheo-esophageal fistula

    International Nuclear Information System (INIS)

    Dunn, E.K.; Man, A.C.; Lin, K.J.; Kaufman, H.D.; Solomon, N.A.

    1983-01-01

    A tracheo-esophageal fistula, developed following radiotherapy for an esophageal carcinoma, was vividly demonstrated by radionuclide imaging. The abnormality was later confirmed by a barium esophagram and endoscopic examinations. The scintigraphic procedure, making use of a Tc-99m sulfur colloid swallow, appears to be a simple alternative method use of a Tc-99m sulfur colloid swallow, appears to be a simple alternative method that may be clinically useful for the diagnosis of such a condition

  18. Sequential Analysis of Gamma Spectra

    International Nuclear Information System (INIS)

    Fayez-Hassan, M.; Hella, Kh.M.

    2009-01-01

    This work shows how easy one can deal with a huge number of gamma spectra. The method can be used for radiation monitoring. It is based on the macro feature of the windows XP connected to QBASIC software. The routine was used usefully in generating accurate results free from human errors. One hundred measured gamma spectra were fully analyzed in 10 minutes using our fast and automated method controlling the Genie 2000 gamma acquisition analysis software.

  19. Scintigraphic evaluation of brain death

    International Nuclear Information System (INIS)

    Park, C. H.; Bai, M. S.; Cho, K. K.; Kim, S. J.; Yoon, S. N.; Cho, C. W.

    1997-01-01

    A law recognizing brain death is a life saving legal measure in patients suffering from badly diseased organs such as kidney, liver, heart, and lung. Such law is being discussed for legalization at the Korean National Assembly. There are various criteria used for brain death in western world and brain scintiscan is one of them. However, the scintiscan is not considered in establishing brain death in the draft of the law. The purpose of this report is to spread this technique in nuclear medicine society as well as in other medical societies. We evaluated 7 patients with clinical suspicion of brain death by various causes. The patient's age ranged from 5 to 39 years. We used 5-20mCi 99m Tc-HMPAO (d.1-hexamethyl propylene amine oxime) or ECD (Ethyl Cysteinate Dimer), lipophilic agents that cross BBB (blood brain barrier). A dynamic study followed by static or SPECT (single photon emission tomography) was performed. Interpretive criteria used for brain death were 1) no intracranial circulation 2) no brain uptake. The second criteria is heavily used. Five of 7 patients were scintigraphically brain dead and the remaining 2 had some brain uptake excluding the diagnosis of scintigraphic brain death. In conclusion, cerebral perfusion study using a lipophilic brain tracer offers a noninvasive, rapid, easy, accurate and reliable mean in the diagnosis of brain death. We believe that this modality should be included in the criteria of brain death in the draft of the proposed Korean law

  20. Scintigraphic defecography in various anorectal disorders

    International Nuclear Information System (INIS)

    Ishii, Yuji; Oya, Masatoshi; Ishikawa, Hiroshi

    1998-01-01

    Scintigraphic defecography was performed using 99m Tc-DATA to quantitatively evaluate defecation in 26 patients after low anterior resection of rectal cancer (LAP-group), 19 patients with chronic constipation (C-group), 11 patients with miscellaneous anal symptoms (AN-group), and 12 normal volunteers. After introducing semi-solid artificial stool containing 99m Tc-DTPA into the rectum, right lateral images of the anorectum were serially obtained during voluntary evacuation. From the time activity curve of the whole rectum, the half emptying time (T1/2) and the percentage of rectal evacuation (evacuation ratio) were calculated. Three abnormal patterns were identified: the flat type in which a temporary elevation of the RI activity, usually recorded in normal volunteers at the beginning of evacuation, was not recorded; the slow type in which T1/2 was over 20 seconds; and the poor evacuation type in which evacuation ratio was less than 80%. In the LAR-group, all the patients having very low anastomosis showed abnormal patterns irrespective of the type of reconstruction (straight or colonic J-pouch). In the C-group, 10 patients who had either slow pattern or poor evacuation pattern were suggested to have outlet obstruction. In the AN-group, the evacuation pattern differed from patient to patient. Scintigraphic defecography is useful in identifying abnormal evacuation in various anorectal disorders. (author)

  1. Scintigraphic defecography in various anorectal disorders

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Yuji; Oya, Masatoshi; Ishikawa, Hiroshi [Dokkyo Univ., School of Medicine, Saitama (Japan). Koshigaya Hospital

    1998-04-01

    Scintigraphic defecography was performed using {sup 99m}Tc-DATA to quantitatively evaluate defecation in 26 patients after low anterior resection of rectal cancer (LAP-group), 19 patients with chronic constipation (C-group), 11 patients with miscellaneous anal symptoms (AN-group), and 12 normal volunteers. After introducing semi-solid artificial stool containing {sup 99m}Tc-DTPA into the rectum, right lateral images of the anorectum were serially obtained during voluntary evacuation. From the time activity curve of the whole rectum, the half emptying time (T1/2) and the percentage of rectal evacuation (evacuation ratio) were calculated. Three abnormal patterns were identified: the flat type in which a temporary elevation of the RI activity, usually recorded in normal volunteers at the beginning of evacuation, was not recorded; the slow type in which T1/2 was over 20 seconds; and the poor evacuation type in which evacuation ratio was less than 80%. In the LAR-group, all the patients having very low anastomosis showed abnormal patterns irrespective of the type of reconstruction (straight or colonic J-pouch). In the C-group, 10 patients who had either slow pattern or poor evacuation pattern were suggested to have outlet obstruction. In the AN-group, the evacuation pattern differed from patient to patient. Scintigraphic defecography is useful in identifying abnormal evacuation in various anorectal disorders. (author)

  2. Experience based on 60 observations of scintigraphic bone exploration using pyrophosphates

    International Nuclear Information System (INIS)

    Mienville, J.-C.

    1975-01-01

    5 to 15 millicuries of technetium 99m-labelled pyrophosphates are injected intraveinously. 3 to 5 hours later, when the blood activity has dropped, the bone uptake is sufficient to give a good scintigraphic image of the skeleton. The skeleton may be explored one segment at a time, using a scanning scintigraph or a scintillation camera, or the whole skeleton front and back may be examined much more quickly with a 'whole-body' device. A study of 60 observations shows the large number of hyperfixations revealed by isotopic explorations in rheumatological diseases. A hyperfixation was observed in almost all bone localities of osteophilic cancers, osteonecrosis, Paget's disease, infections osteo-arthritis and algoneurodystrophy. On the other hand the isotopic test was found to be negative or inefficient in arthroses, osteoporosis and local bone manifestations of Kahler's or Hodgkin's disease. Finally inflammatory arthritis was detectable by scintigraphy in about half the cases studied. In reality a hyperfixation reflects a local rise in the metabolic activity of the bone at the moment of the examination. As a result the scintigraphic images lack specificity. This factor must therefore be accounted for in the patient's records and isotopic results compared with those of clinical and para-clinical examinations [fr

  3. Scintigraphic findings in ankylosing spondylitis.

    Science.gov (United States)

    Lentle, B C; Russell, A S; Percy, J S; Jackson, F I

    1977-06-01

    A prospective study of bone scintigraphic findings has been carried out in 63 patients, firmly diagnosed as having ankylosing spondylitis. In addition to abnormal uptake of the radiotracer at the sacroiliac joints, a peripheral arthropathy has been a common finding, particularly in the proximal joints, occurring in up to 50% of patients. Increased uptake of radiotracer in the spine has also been found both diffusely and focally. Focal increases have been noted at the apophyseal joints in 40% of patients and in three patients with a sterile intervertebral diskitis, an unusual complication of this disease only diagnosed in two patients after bone scintigraphy.

  4. Statistical and heuristic image noise extraction (SHINE): a new method for processing Poisson noise in scintigraphic images

    International Nuclear Information System (INIS)

    Hannequin, Pascal; Mas, Jacky

    2002-01-01

    Poisson noise is one of the factors degrading scintigraphic images, especially at low count level, due to the statistical nature of photon detection. We have developed an original procedure, named statistical and heuristic image noise extraction (SHINE), to reduce the Poisson noise contained in the scintigraphic images, preserving the resolution, the contrast and the texture. The SHINE procedure consists in dividing the image into 4 x 4 blocks and performing a correspondence analysis on these blocks. Each block is then reconstructed using its own significant factors which are selected using an original statistical variance test. The SHINE procedure has been validated using a line numerical phantom and a hot spots and cold spots real phantom. The reference images are the noise-free simulated images for the numerical phantom and an extremely high counts image for the real phantom. The SHINE procedure has then been applied to the Jaszczak phantom and clinical data including planar bone scintigraphy, planar Sestamibi scintigraphy and Tl-201 myocardial SPECT. The SHINE procedure reduces the mean normalized error between the noisy images and the corresponding reference images. This reduction is constant and does not change with the count level. The SNR in a SHINE processed image is close to that of the corresponding raw image with twice the number of counts. The visual results with the Jaszczak phantom SPECT have shown that SHINE preserves the contrast and the resolution of the slices well. Clinical examples have shown no visual difference between the SHINE images and the corresponding raw images obtained with twice the acquisition duration. SHINE is an entirely automatic procedure which enables halving the acquisition time or the injected dose in scintigraphic acquisitions. It can be applied to all scintigraphic images, including PET data, and to all low-count photon images

  5. Scintigraphic evidence of transplanted hepatocytes in spleen and liver

    International Nuclear Information System (INIS)

    Henne-Bruns, D.; Kremer, B.; Gramminger, K.; Broelsch, C.

    1986-01-01

    In rats suffering from hepatic enzymatic deficiency transplanted hepatocytes could be evidenced scintigraphically in liver, spleen and granulomas. In pigs, however, it is very difficult to demonstrate transplanted hepatocytes by scintiscanning because of the thickness of the tissues and the high background radiation in large animals

  6. Unusual and subtle scintigraphic findings in the evaluation of the battered child

    International Nuclear Information System (INIS)

    Howard, J.L.; Barron, B.J.; Smith, G.G.

    1988-01-01

    Nuclear medicine imaging plays a key role in the evaluation of skeletal trauma. Recent findings in our department show that diagnoses other than skeletal trauma are often identified by means of subtle and unusual scintigraphic findings. The subject material will place strong emphasis on the less mentioned but often more important visceral and intracranial injury. Specific scintigraphic abnormalities to be demonstrated, with appropriate correlative radiographs, include (1) visceral and soft tissue (eg, duodenal hematoma, splenic laceration, renal contusion, hepatic hematoma, rhabdomyolysis and soft-tissue hematoma); (2) cranial (eg, intracranial bleeding, edema, and infarct, cephalohematoma, skull fracture, and widening of sutures; and (3) skeletal (various subtle abnormalities)

  7. Investigation of gamma spectra analysis

    International Nuclear Information System (INIS)

    Wu Huailong; Liu Suping; Hao Fanhua; Gong Jian; Liu Xiaoya

    2006-01-01

    In the investigation of radiation fingerprint comparison, it is found out that some of the popular gamma spectra analysis software have shortcomings, which decrease the radiation fingerprint comparison precision. So a new analysis software is developed for solving the problems. In order to display the advantage of developed program, some typical simulative warhead gamma spectra are analyzed respectively by present software and GAMMAVISION and GENNIE2000. Present software can be applied not only in nuclear warheads deep-cuts verification, but also in any radiation measurement field. (authors)

  8. Evolution of scintigraphic renal lesions in children after an episode of acute pyelonephritis

    International Nuclear Information System (INIS)

    Donoso, Gilda; Lagos, Elizabeth; Rosati, Pia; Hevia, Pilar; Cuevas, Karen; Lobo, Gabriel; Perez, Andres; Gutierrez, Daniela

    2012-01-01

    Background: Abnormal Dimercaptosuccinic acid (DMSA) renal scintigraphy performed six months after an acute pyelonephritis (AP) is generally interpreted as scarring. Aim: To perform a follow up of childhood patients showing scintigraphic renal lesions during the acute phase of pyelonephritis (within 7 days from the beginning of fever). Material and Methods: A scintigraphic control was carried out at 5-7 months and, in case of persistent lesions, an additional late scintigraphy at 10-13 months. All patients were followed clinically for one year and those with a relapse of urinary tract infection were excluded from the study. Results: Eighty five patients with a median age of 8 months were included. Among these, the first scintigraphic control was normal in 59 (69%) and abnormal in 26 patients (31%). In five of these 26 patients (5/26:19%-5/85:6%), a considerable regression of the lesions was obvious on the early control, and normalized completely on the late control. When expressing the results in kidney units, 107 showed lesions during the acute phase of infection; 69% was normal at the early control. Thirty three showed lesions persisting at the early control (31%) and 7 out of these 33 (21%) became normal on the late control (7/107: 7%). In total, 25% of the children included in the study (24% of the kidney units) remained with renal sequelae one year after the initial episode of AP. Conclusions: The persistence of scintigraphic lesions six months after an episode of AP, does not necessarily correspond to permanent scars, since normalization can sometimes be observed on late controls

  9. Prompt gamma-ray activation analysis (PGAA)

    International Nuclear Information System (INIS)

    Kern, J.

    1996-01-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs

  10. Prompt gamma-ray activation analysis (PGAA)

    Energy Technology Data Exchange (ETDEWEB)

    Kern, J [Fribourg Univ. (Switzerland). Inst. de Physique

    1996-11-01

    The paper deals with a brief description of the principles of prompt gamma-ray activation analysis (PGAA), with the detection of gamma-rays, the PGAA project at SINQ and with the expected performances. 8 figs., 3 tabs., 10 refs.

  11. Investigation of gamma spectra analysis

    International Nuclear Information System (INIS)

    Wu Huailong; Liu Suping; Hao Fanhua

    2006-12-01

    During the investigation of radiation fingerprint comparison, it is found out that the popular gamma spectra analysis softwares are faultful, which decrease the precision of radiation fingerprint comparison. So a new analysis software is development for solving the problems. In order to display the advantage of new program, some typical simulative gamma spectra of radiation source are analyzed respectively by our software and GAMMAVISION and GENNIE2000. The software can be applied not only in nuclear warheads deep-cuts verification, but also in any radiation measurement field. (authors)

  12. 99m-Tc HMDP bone scintigraphic findings of gouty arthropathy of both hands

    International Nuclear Information System (INIS)

    Shih, Wei-Jen; Domstad, P.A.; Purcell, M.; DeLand, F.H.

    1988-01-01

    The 99m Tc hydroxy methylene diphosphonate scintigraphic findings of both hands are correlated to the radiographic findings in a patient with a 30-year history of gouty arthropathy. Scintigraphic differentiation of the type of arthritis on the basis of uptake pattern is difficult. However, the findings of rheumatoid arthritis are confined to the joints and usually the involvement is symmetrical. With gout there is a tendency toward asymmetrical, bilateral, multifocal joint involvement with areas of intense abnormal uptake; because of the associated soft tissue swelling, the intense uptake usually extends beyond the involved joints. (author)

  13. 20. Quality assurance and quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Vavrejn, B.

    1989-01-01

    Quality control principles to be applied when taking over and using nuclear medicine instrumentation are given. Such instrumentation includes activity meters, gamma detectors for in vitro measurements (manual or automated instruments), gamma detectors for in vivo measurements (with one or several probes), 'movable' scintigraphs and 'steady' scintigraphs (gamma cameras). (Z.S.)

  14. Scintigraphic findings in ankylosing spondylitis

    International Nuclear Information System (INIS)

    Lentle, B.C.; Russell, A.S.; Percy, J.S.; Jackson, F.I.

    1977-01-01

    A prospective study of bone scintigraphic findings has been carried out in 63 patients, firmly diagnosed as having ankylosing spondylitis. In addition to abnormal uptake of the radiotracer at the sacroiliac joints, a peripheral arthropathy has been a common finding, particularly in the proximal joints, occurring in up to 50 percent of patients. Increased uptake of radiotracer in the spine has also been found both diffusely and focally. Focal increases have been noted at the apophyseal joints in 40 percent of patients and in three patients with a sterile intervertebral diskitis, an unusual complication of this disease only diagnosed in two patients after bone scintigraphy

  15. Scintigraphic findings on 99mTc-MDP, 99mTc-sestamibi and 99mTc-HMPAO images in Gaucher's disease

    International Nuclear Information System (INIS)

    Mariani, G.; Molea, N.; La Civita, L.; Porciello, G.; Lazzeri, E.; Ferri, C.

    1996-01-01

    We report here on the use of the lipophilic cationic complex technetium-99m sestamibi ( 99m Tc-MIBI), employed as an indicator of increased cellular density and metabolic activity, to evaluate Gaucher cell infiltrates in the bone marrow; 99m Tc-hexametazime ( 99m Tc-HMPAO) was also employed, as a pure indicator of lipidic infiltration in the bone marrow. A 67-year-old patient with known type 1 Gaucher's disease presented with a painful left hip and knee and difficulty in gait subsequent to traumatic fracture of the left femoral neck that had required implant of a fixation screw-plaque. Bone scan with 99m Tc-methylene diphosphonate revealed reduced uptake at the distal metaphyseal-epiphyseal femoral region. In addition, whole-body maps and spot-view acquisitions of the thighs and legs were recorded at both 30 min and 2.5 h after the injection of 99m Tc-MIBI: the scintigraphic pattern clearly showed increased uptake at several sites involved by Gaucher deposits in the bone marrow (both knees, with variable intensity in different areas), matching the bone changes detected by conventional x-ray. The target to non-target ratios slowly decreased with time, from an average value of 2.25 in the early scan to an average value of 2 in the delayed scan. The lipid-soluble agent 99m Tc-HMPAO exhibited a superimposable scintigraphic pattern of accumulation at the involved sites, though with lower target to non-target ratios (1.27-1.48). The results obtained in this patient suggest a potential role of 99m Tc-MIBI in the scintigraphic evaluation of Gaucher's lipid deposits in the bone marrow. If the results are confirmed in other patients, this radiopharmaceutical would offer clear advantages over 133 Xe because of its wider availability and greater practicality (i.v. administration of 99m Tc-MIBI versus inhalation of 133 Xe, and use of a single gamma camera instead of two as with 133 Xe). (orig.). With 3 figs

  16. Scintigraphic study of gastric emptying with colloidal tin

    International Nuclear Information System (INIS)

    Rodríguez Paleo, Lester; Nuez Vilar, Maricela; Machado Lois, Marisel; López González, María Karla; Torres Leyva, Oscar; Izquierdo Izquierdo, Yimel; García González, Idelsy; Conesa Gonzalez, Ana Ibis

    2016-01-01

    Gastroparesis is defined as a delay in gastric emptying in the absence of mechanical obstruction, associated with symptoms such as nausea and / or vomiting, feeling of postprandial gastric fullness, early satiety or epigastric pain for more than 3 months. The gold standard in the diagnosis of delayed gastric emptying scintigraphy is gastric emptying and radiopharmaceutical has been used more 99m Tc-sulfur colloid not available in the country. In order to evaluate the usefulness of colloidal tin in the scintigraphic gastric emptying study, a descriptive study was conducted in 64 patients over 18 years using as radiopharmaceutical 99m Tc-Sn colloid. 31% of patients had symptoms. The emptying time was normal in 50 cases and the association of gastroparesis symptoms was observed in 20 (15 diabetic and 5 non-diabetic), 9 patients had a delayed emptying, but reported no symptoms. Gastroparesis was more frequent in women than in men (35% versus 21%). 21% of patients had a moderate delayed gastric emptying. Conclusions: The results obtained with 99m Tc-Sn colloid are comparable to those reported by other authors using 99m Tc-SC in the scintigraphic assessment of gastric emptying. (author)

  17. Scintigraphic portrayal of β receptors in the heart

    International Nuclear Information System (INIS)

    Sisson, J.C.; Wieland, D.M.; Koeppe, R.A.; Normolle, D.; Frey, K.A.; Bolgos, G.; Johnson, J.; Van Dort, M.E.; Gildersleeve, D.L.

    1991-01-01

    Myocardial β adrenergic receptors play important roles in physiology and disease, but the receptors have not before been portrayed. The β antagonist, iodocyanopindolol (ICYP), was used to develop a scintigraphic method for depicting the receptors in the living heart. Labeled with 125I, ICYP bound firmly to β receptors in the rat heart; the data conformed to a mathematical model. In vivo saturation kinetics indicated binding sites with two affinities. Inhibition of ICYP binding by beta antagonists of different potency and different selectivity for β-1 and β-2 receptors produced the expected pharmacologic effects. Inhibition by lipophilic and hydrophilic antagonists gave no evidence that ICYP was appreciably bound to internalized receptors. Fractional binding by tracer quantities of (-) ICYP and ± ICYP demonstrated stereospecificity. Labeled with 123I, ICYP bound to the hearts of intact dogs so that scintigraphic tomographs depicted ventricular myocardium. Small doses of beta antagonists selectively reduced the binding of ICYP to lung enabling better visualization of the heart. Thus, 123I-ICYP appears to portray the beta receptors in the living heart, and the characteristics of binding permit the development of mathematical models and lay the basis for quantifying this receptor binding

  18. Scintigraphic evaluation of the esophageal transit in patients with polymyositis

    International Nuclear Information System (INIS)

    Viterbo, B.G.; Moriguchi, S.M.; Rocha, O.M.; Henry, M.A.C.A.

    2002-01-01

    Aim: To evaluate the esophageal function of patients with polymyositis. Materials and Methods: Nine patients with polymyositis were evaluated, 8 female and 1 male. The ages ranged from 20 to 65 years. Seventeen healthy volunteers (4 female and 13 male) were also evaluated as control group. The median age was 28 years (20 to 41). All patients and controls were submitted to the esophageal scintigraphy performed after the oral ingestion of 37 MBq of stannous colloidal labeled with 99m Tc and diluted in 10 ml of water. The dynamic study was acquired on the supine position, 1 frame/0.5 sec., during 50 sec with a large-field-of-view gamma-camera. Time-activity curves were generated from ROIs positioned over the three portions of the esophagus (upper, middle and distal). The radiotracer retention (RR) after 15 seconds of the peak of radioactivity on the whole esophagus was calculated as a percentage. The pattern of the time-activity curves was classified as normal, as hypomotility or as a mixed pattern, with associated dysmotility. Non-parametric statistical analysis was made with the Mann-Whitney test and the significance level was set at 5%. Results: All the patients with polymyositis presented esophageal motor alterations on the esophageal scintigraphy. Eight (88.9%) patients revealed a mixed pattern at the three segments of the esophagus and 1 (11.1%) patient presented hypomotility at the middle and distal segments. All the healthy volunteers showed normal results at the scintigraphic study. The mean RR of the patients with polymyositis was 69.1% and 4.4% on the control group (P<0.0001). Conclusion: The esophageal transit scintigraphy is a sensitive and useful method to evaluate functional disorders of the esophagus of patients with polymyositis

  19. Is there a role for scintigraphic imaging of bone manifestations in Gaucher disease? A review of the literature

    International Nuclear Information System (INIS)

    Mikosch, P.; State Hospital Klagenfurt; Kohlfuerst, S.; Gallowitsch, H.J.; Kresnik, E.; Lind, P.; Mehta, A.B.; Hughes, D.A.

    2008-01-01

    Gaucher disease is the most prevalent inherited, lysosomal storage disease and is caused by deficient activity of the enzyme β-glucocerebrosidase. Bone and bone marrow alterations are frequent in the most prevalent non-neuronopathic form of Gaucher disease. Imaging of bone manifestations in Gaucher disease is performed by a variety of imaging methods, conventional X-ray and MRI as the most frequently and most important ones. However, different modalities of scintigraphic imaging have also been used. This article gives an overview on scintigraphic imaging with respect to bone manifestations in Gaucher disease discussing the advantages and limitations of scintigraphic imaging in comparison to other imaging methods. (orig.)

  20. The skeletal changes of progressive systemic scleroderma (PSS), of exclusive Raynaud phenomenon and of circumscript scleroderma in a gamma camera scintigraph

    International Nuclear Information System (INIS)

    Ulbrich, T.

    1987-01-01

    The bases of this study are the skeletal scintigraphs of altogether 34 patients with the three forms of scleroderma mentioned in the title. The PSS shows a polytropic, symmetric distribution pattern, the exclusive Raynaud's phenomenon shows a basic skeleton which is unchanged in contrast to circumscript scleroderma, with which also the larger joints are relatively more frequently attacked than the little ones. As a result of high sensitivity skeletal scintiscanning makes possible an early recognition of osseous changes and is there with superior to X-radiology and should then see an increased use for the clarification of the diagnosis of arthropathy in scleroderma. (TRV) [de

  1. Scintigraphic anatomy of coronary artery disease in digital thallium-201 myocardial images

    International Nuclear Information System (INIS)

    Wainwright, R.J.

    1981-01-01

    One hundred and eight patients with single and multiple vessel coronary artery disease confirmed by arteriography were evaluated by exercise thallium-201 ( 201 Tl) myocardial scintigraphy to determine the scintigraphic appearances of specific coronary stenoses. In general proximal stenoses caused more widespread, but not necessarily more severe, myocardial tracer deficit, than distal stenoses. In particular, proximal dominant right coronary artery disease was specifically associated with extensive inferior wall tracer deficit in the anterior scintigram, whereas proximal left circumflex disease caused similar tracer depletion best visualised in the left lateral scintigram. A triad of uptake defects was caused by left anterior descending coronary artery disease; one of these defects called 'diagonal window tracer deficit' was the most useful scintigraphic sign distinguishing proximal from distal disease in the left anterior descending coronary artery. Certain scintigraphic patterns of 201 Tl myocardial accumulation appear invaluable in the noninvasive localisation of stenoses within specific coronary arteries and thus may be useful in predicting life-threatening coronary artery disease which should be confirmed by definitive coronary arteriography. The digital 201 Tl myocardial scintigram also provides an independent functional guide to the interpretation of coronary arteriograms and may be helpful in the planning of aortocoronary bypass graft surgery. (author)

  2. Differentiation of scintigraphic-morphological changes of the thyroid by diffusion techniques

    International Nuclear Information System (INIS)

    Auf Hamada, T.

    1974-01-01

    The essay was based on the question of the possibility of obtaining a diagnostic parameter by determining the thyroidal blood circulation with the aid of gamma-camera examination. A series of confirmed cases of hyperthyreoses, adenomas, cycts, and malignomas was selected trying to distinguish the criteria of the blood circulation of clinically, serologically, and scintigraphically normal organs. The blood circulation of the normal-sized, or slightly enlarged thyroid showed in all cases a normal curve with constant increase, but without a peak during the period of examination (60 sec.). If we look at the curve in the case of hyperthyreosis, we see, in contrast to the normal findings a notably faster accumulation of the nuclide in the thyroid, with a slightly reduced enrichment in the further course of the examination, in comparison to the initial part of the curve. The blood circulation curves of decompensated adenomas show, in contrast to the compensated adenoma, also a faster initial accumulation, in relation to the total height of the impulse, which is quantitatively increased by 1/3. If we compare all adenomas, we see that the curve ascends continously, although only in two of seven cases a peak could be differentiated, which might be due to a faster thyroid clearance. (orig./AJ) [de

  3. Gamma activation analysis with microtron

    International Nuclear Information System (INIS)

    Fiderkiewicz, A.; Kierzek, J.; Parus, J.; Swiderska-Kowalczyk, M.; Wolski, W.; Zoltowski, T.

    1989-01-01

    The physical principles of gamma activation analysis, its capabilities as well as its application to analyse polymetallic ores with use of mean power microtron are presented. Limits of detection and determination for above twenty elements occurring in those ores with use of short- and longlived radioisotopes are specified. The work contains conception of construction of race-track microtron with electrons energy adjusted in 10-30 MeV range and with current not less than 20 μA. Besides the development of microtrons, the reason for choosing the race-track construction for gamma activation analysis is given. 69 refs., 35 figs., 5 tabs. (author)

  4. Proceedings of the workshop on multiple prompt gamma-ray analysis

    International Nuclear Information System (INIS)

    Ebihara, Mitsuru; Hatsukawa, Yuichi; Oshima, Masumi

    2006-10-01

    The workshop on 'Multiple Prompt Gamma-ray Analysis' was held on March 8, 2006 at Tokai. It is based on a project, 'Developments of real time, non-destructive ultra sensitive elemental analysis using multiple gamma-ray detections and prompt gamma ray analysis and its application to real samples', one of the High priority Cooperative Research Programs performed by Japan Atomic Energy Agency and the University of Tokyo. In this workshop, the latest results of the Multiple Prompt Gamma ray Analysis (MPGA) study were presented, together with those of Neutron Activation Analysis with Multiple Gamma-ray Detection (NAAMG). The 9 of the presented papers are indexed individually. (J.P.N.)

  5. Intercomparison of gamma ray analysis software packages

    International Nuclear Information System (INIS)

    1998-04-01

    The IAEA undertook an intercomparison exercise to review available software for gamma ray spectra analysis. This document describes the methods used in the intercomparison exercise, characterizes the software packages reviewed and presents the results obtained. Only direct results are given without any recommendation for a particular software or method for gamma ray spectra analysis

  6. Targeting of macrophages for the scintigraphic evaluation of inflammatory lesions in a model of radio-induced inflammation in pigs

    International Nuclear Information System (INIS)

    Hoffschir, D.; Daburon, F.; Normier, G.; Binz, H.; Le Pape, A.

    1991-01-01

    For a new scintigraphic strategy based on the targeting of macrophages recruited by inflammatory lesions, a specific ligand able to interact with these cells both in vitro and in vivo has been developed. J001 is a 34 KDa acylated peptidopoly 1-3 galactoside isolated from proteoglycans of a non pathogenic strain of klebsiella. When labelled with 99mTc then administrated by aerosol, this agent has been demonstrated to be a potent tool for the scintigraphic imaging of inflammatory lymph nodes in experimental berylliosis and in patients with sarcoidosis, lung tumors and ganglionic metastases. An experimental model was developed in pigs using an acute and localized muscular γ irradiation in the limb and skin resection to prevent ulceration. Dynamic imaging was performed during two hours after intravenous injection of 1 mg J001 labelled with 370 MBq 99mTc in the presence of 0.125 mg stannous fluoride. The perfusion of the lesions was evaluated from scintigraphic data obtained both 15 min after IV injection of J001 or 99mTc 04-. The intensity of the fixation of J001 was quantified 2 hours after injection and expressed as a scintigraphic ratio: R2h = cpm in lesion / cpm in a defined healthy area in the same limb. After induction of irradiation, scintigraphic ratios exhibited a progressive increase to reach a maximum (R2h = 3.6) after 3 months. Then, they decreased to recover a normal value about 6 months after irradiation. At that time, histological controls and clinical observations exhibited a significant decrease in inflammatory reaction, macrophages recruitment and apparition of fibrosis. J001 fixation was very sensitive to corticosteroids that resulted in a complete clearing of the scintigraphic images 12 to 24 hours after treatment. Two weeks were then required for a complete recovery of the inflammatory reaction and J001 fixation. So, targeting of macrophages with J001 should offer a sensitive and specific tool for the scintigraphic assessment of inflammation and

  7. Preliminary analysis of the KAERI RCCS Experiment Using GAMMA+

    Energy Technology Data Exchange (ETDEWEB)

    Khoza, Samukelisiwe; Tak, Nam-il; Lim, Hong-Sik; Lee, Sung-Nam; Cho, Bong-Hyun; Kim, Jong-Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    This paper describes the analysis of the KAERI RCCS experiment. GAMMA+ code was used for analysis of the RCCS 1/4-scale natural cooling experimental facility designed and built at KAERI to verify the performance of the natural circulation phenomenon. The results obtained from the GAMMA+ analysis showing the temperature profiles and flow rates at steady state were compared with the results from the preliminary experiments conducted in this facility. GAMMA+ analysis for the KAERI RCCS experimental setup was carried out to understand its natural circulation behavior. The air flow rate at the chimney exit achieved by experiments was from to be almost same as that of GAMMA+.

  8. Use of gamma spectroscopy in activation analysis; Utilisation de la spectrographie gamma dans l'analyse par activation

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, [Commissariat a l' Energie Atomique, Saclay (France).Centre d' Etudes Nucleaires

    1959-07-01

    Brief review of the principles of activation analysis: calculation of activities, decay curves, {beta} absorption curves, examples of application. - Principle and description of the {gamma} spectrograph. - Practical utilisation of the {gamma} spectrograph: analysis by activation, analysis by {beta} - x fluorescence. - Sensitivity limit of the method and precision of the measurements. - Possible improvements to the method: {gamma} spectroscopy with elimination of the Compton effect. (author) [French] Bref rappel des principes de l'analyse par activation: calcul des activites, courbes de decroissance, courbes d'absorption {beta}, exemples d'utilisation. - Principe et description du spectrographe {gamma}. - Utilisation pratique de la spectrographie {gamma}: analyse par activation, analyse par fluorescence {beta} - x. - Limite de sensibilite de la methode et precision des mesures. - Ameliorations possibles de la methode: spectrographe {gamma} avec elimination de l'effet Compton. (auteur)

  9. The holistic analysis of gamma-ray spectra in instrumental neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Blaauw, M

    1993-11-15

    The subject is the computerized analysis of the gamma-ray spectra in INAA. This analysis can be separated in three parts: The conversion of the spectra to information on {gamma}-ray energies and their relative intensities (spectrum reduction), the determination of the relation between the intensity of a {gamma}-ray and the amount of the corresponding element present in the sample (standardization) and the attribution of the {gamma}-ray energies to the elements, including the subsequent computation of the amounts of the elements (interpretation). A {gamma}-ray spectrum can be considered to be the linear sum of the {gamma}-ray spectra of the individual radionuclides present in the sample. Knowing the relative activities of the different radionuclides that may be produced by activation of a single element, a {gamma}-ray spectrum in INAA can also be considered to be the linear sum of the spectra of the elements. This principle has hitherto not been used in INAA to analyze the spectra by linear least squares methods, using all {gamma}-ray energies observed in the spectrum. The implementation of this `holistic` approach required that attention be paid to both spectrum reduction, standardization and interpretation. The thesis describes the methods developed for the holistic analysis of {gamma}-ray spectra in INAA, and present results of experimental comparisons between the holistic and other approaches. (orig./HP).

  10. Dynamic scintigraphic studies after oesophageal reconstruction

    International Nuclear Information System (INIS)

    Maliska, C.M.; Maliska, C.; Pinto, E.; Castro, L.; Fonseca, L.B.E; Miranda, M.

    1997-01-01

    Full text: We have studied the oesophageal transit and gastric emptying in the monitoring of the effect of oesophageal reconstruction surgery. Oncologic patients were evaluated after oesophageal reconstruction surgery with gastric (14 patients) or colonic (5 patients) tube and they were compared with 15 healthy volunteers, using scintigraphic method with liquid food (S-colloid-Tc99m). In the oesophageal transit studies there were no significant statistical differences among the three groups, when we have just considered to two superior (of the three) segments, as oesophagus, showing that the distal neo-tube works just like the stomach of normal volunteers

  11. Prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Goswami, A.

    2003-01-01

    Prompt gamma neutron activation analysis (PGNAA) is a technique for the analysis of elements present in solid, liquid and gaseous samples by measuring the capture gamma rays emitted from the sample during neutron irradiation. The technique is complementary to conventional neutron activation analysis (NAA) as it can be used in number of cases where NAA fails. Though the technique was first used in sixties, the advantage of the technique was first highlighted by Lindstrom and Anderson. PGNAA is increasingly being used as a rapid, instrumental, nondestructive and multielement analysis technique. A monograph and several excellent reviews on this topic have appeared recently. In this review, an attempt has been made to bring out the essential aspects of the technique, experimental arrangement and instrumentation involved, and areas of application. Some of the results will also be presented

  12. Gamma-Ray Spectrum Analysis Software GDA

    International Nuclear Information System (INIS)

    Wanabongse, P.

    1998-01-01

    The developmental work on computer software for gamma-ray spectrum analysis has been completed as a software package version 1.02 named GDA, which is an acronym for Gamma-spectrum Deconvolution and Analysis. The software package consists of three 3.5-inch diskettes for setup and a user's manual. GDA software can be installed for using on a personal computer with Windows 95 or Windows NT 4.0 operating system. A computer maybe the type of 80486 CPU with 8 megabytes of memory

  13. Scintigraphic Methods to Evaluate Alterations of Gastric and Esophageal Functions in Female Obesity

    Directory of Open Access Journals (Sweden)

    Özgür Ömür

    2014-02-01

    Full Text Available Objective: Altered gastrointestinal function has frequently been observed in obese patients. The aim of this study was to investigate the frequency of gastro-esophageal reflux (GER and to determine the alterations of gastric emptying and esophageal transit by scintigraphic methods in obese patients. Methods: Scintigraphic studies of 50 obese female non-diabetic patients who had not received any treatment for weight control were retrospectively reviewed. Mean Body Mass Index (BMI was 34.96±3.04 kg/m² (range:32-39 kg/m². All subjects were submitted to scintigraphic evaluation of esophageal transit, gastro-esophageal reflux, gastric emptying and presence of Helicobacter pylori infection. The data of obese patients were compared with those of sex-age matched 30 non-obese cases who were selected from our clinical archive. Results: In obese group, seventeen (34% patients were found to be GER positive scintigraphically; mean gastric emptying time (t½ was 59.18±30.8 min and the mean esophageal transit time was 8.9±7.2 s. Frequency of positive GER scintigraphy and the mean value of esophageal transit time were significantly higher in obese patients than non-obese control subjects. Gastric emptying time and esophageal transit time values were significantly longer in GER positive obese patients than GER negative ones. There was no statistically significant difference in the frequency of positive C14 urea breath test between obese and non-obese subjects and there were also no statistically significant correlations between BMI, GER, esophageal transit time and gastric emptying time. Conclusion: In our study, 42 of the 50 obese patients had esophago-gastric motility alterations. The significance of these alterations in obesity is not fully understood, but it is believed that these changes could be because of potential contributing factors in the development or maintenance of obesity or changes in eating habits

  14. The 'fragmented' scintigraphic lung pattern in pulmonary lymphangitic carcinomatosis secondary to breast cancer.

    Science.gov (United States)

    Vattimo, A V; Burroni, L; Bertelli, P; Vella, A; Volterrani, D

    1998-01-01

    Pulmonary lymphangitic carcinomatosis (PLC) is an unusual presentation of diffuse infiltrative lung disease. In this report we present two cases secondary to breast cancer; the diagnosis was made by means of transbronchial lung biopsy or postmortem examination. The goal of this study was to analyze the scintigraphic pattern of pulmonary perfusion performed with technetium-99m macroaggregated albumin (99mTc-MAA) in the hope of achieving improved recognition of PLC and its subsequent diagnosis. Upon admission, both patients underwent routine clinical exams followed by chest X-rays. The second patient also underwent CT examination, and both were ultimately examined using pulmonary perfusion scintigraphy with 99mTc-MAA. In the various exams performed, the most reliable and easily identified diagnostic finding turned out to be a characteristic 'fragmented' lung pattern revealed with the perfusion lung scan. Unfortunately, in both cases the patients' conditions rapidly worsened and death occurred shortly following scintigraphy. We were able to conclude that the recognition of the mentioned fragmented scintigraphic lung pattern may be useful in suspected PLC, whereas the nonspecific clinical presentation of this pathology makes diagnosis extremely difficult, with the most significant results being achieved through a comparison of scintigraphic and high resolution CT data.

  15. Scintigraphic evaluation of gastroesophageal reflux

    International Nuclear Information System (INIS)

    Malmud, L.S.; Fisher, R.S.

    1983-01-01

    When patients have symptomatic gastroesophageal reflux disease, their symptoms usually respond to conventional therapeutic measures. In some patients, however, the symptoms may persist despite the application of standard treatment regimens. It is in these instances that the clinician may employ extensive diagnostic tests to determine the cause of the patient's complaints. Because the introduction of gastroesophageal scintigraphy, a number of other techniques were employed to evaluate gastroesophageal reflux. These include barium esophagography, barium cineesophagography; endoscopy; esophageal mucosal biopsy; esophageal manometry; the acid-clearance test; and acid-reflux testing. Each of the nonscintigraphic techniques has a limitation either in its sensitivity or in the requirement for endogastric intubation. In addition, with the exception of the scintigraphic method, none of the tests permits quantitation of reflux

  16. Scintigraphic evaluation of Zenker's diverticulum

    Energy Technology Data Exchange (ETDEWEB)

    Valenza, Venanzio; Perotti, Germano; Di Giuda, Daniela [Institute of Nuclear Medicine, Policlinico A. Gemelli, Catholic University of Sacred Heart, Largo Gemelli 8, 00168, Rome (Italy); Castrucci, Gioacchino [Department of Surgery, Bel Colle Hospital, Viterbo (Italy); Celi, Giuseppe; Restaino, Gennaro [Institute of Radiology, Catholic University of Sacred Heart, Rome (Italy)

    2003-12-01

    Zenker's diverticulum (ZD) is a rare pathology, with a prevalence of between 0.01% and 0.11%. Definitive diagnosis of ZD can be accomplished by contrast radiographic examination (barium oesophagogram, BE); oesophageal manometry (ME) is recommended mainly for those patients suffering from dysphagia and/or gastro-oesophageal reflux. The aims of the present study were to assess whether oropharyngo-oesophageal scintigraphy (OPES) is able (a) to visualise ZD and (2) to demonstrate the corresponding alteration in the swallowing phases. We studied 16 patients (nine male, seven female, mean age 67.4 years), and 17 healthy volunteers (ten male, seven female, mean age 53 years) as a control group. All the patients underwent ME, BE and OPES. Nine patients underwent surgery and six of them were re-evaluated after 6 months. We administered 10 ml of water with 37 MBq of technetium-99m colloid through a straw, acquiring 480 sequential images (0.125 s/frame for a total of 60 s) with the patient standing in front of the gamma camera in the 80 right anterior oblique position. Two static images were performed at the end of the dynamic phase, before and after ingestion of 100 ml of unlabelled water to evaluate the presence of inflammation (persistence of radioactivity in the diverticulum or oesophagus). Study of the sequential scintigraphic images and time-activity curves permitted both qualitative (diverticulum visualisation, multiple deglutitions, reflux, presence of inflammation) and quantitative analyses [oral, pharyngeal and oesophageal transit times and retention indexes, tracheal aspiration percentage] of swallowing disorders. OPES showed a good correlation with the results of other diagnostic techniques usually performed in patients with this pathology, and especially with ME in the evaluation of oropharyngeal phase disorders. Furthermore, OPES is a sensitive and simple technique that is well tolerated and entails a low irradiation dose for patients. (orig.)

  17. Scintigraphic diagnosis of experimentally induced pericarditis in dogs using 99sup(m)Tc-labelled pyrophosphate

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubizek, J.; Simon, J.; Veverkova, O.; Karlova Universita, Hradec Kralove

    1981-01-01

    In the present paper the possibilities of scintigraphic diagnosis of experimental pericarditis are discussed. Pericarditis was induced by either talc or formaldehyde intrapericardially. In all animals the administration of talc as well as formaldehyde produced inflammatory changes which were more serious after formaldehyde. The scan of the talc pericarditis was carried out on the 7th day after operation and of the formaldehyde pericarditis on the 3rd, 7th and 14th day. No positive scintigraphic finding was made in any of the experimental animals, apart from a massive incorporation in the operation scars. The counting of radioactive impulses after the exstirpation of the tissue samples confirmed the scintigraphic findings. Statistical evaluation did not reveal any essential difference between the accumulation of the radiopharmaceutical into the pericarditis as well as into the pericardial bag in comparison with the control animals. Although our model does not exactly reflect the situation of patients suffering from pericarditis it may be assumed that pyrophosphate scintigraphy is not suitable for the diagnosis of acute pericarditis in clinical practice. (orig.) [de

  18. Serendipity in scintigraphic gastrointestinal bleeding studies

    International Nuclear Information System (INIS)

    Goergen, T.G.

    1983-01-01

    A retrospective review of 80 scintigraphic bleeding studies performed with Tc-99m sulfur colloid or Tc-99m labeled red blood cells showed five cases where there were abnormal findings not related to bleeding. In some cases, the abnormalities were initially confused with bleeding or could obscure an area of bleeding, while in other cases, the abnormalities represented additional clinical information. These included bone marrow replacement related to tumor and radiation therapy, hyperemia related to a uterine leiomyoma and a diverticular abscess, and a dilated abdominal aorta (aneurysm). Recognition of such abnormalities should prevent an erroneous diagnosis and the additional information may be of clinical value

  19. Survey of 26 suprarenal scintigraphs on Cushing's syndrome patients

    International Nuclear Information System (INIS)

    Venot, A.; Luton, J.P.; Roucayrol, J.C.; Bricaire, H.

    On the basis of the results of 26 Cushing's syndrome examinations some new scintigraphic aspects are described, suprarenal scintigraphy is compared with retroperitoneal insufflation, its value in the observation of a medical treatment of Cushing's disease is demonstrated and finally some preliminary results are given on the application in the same pathological context, of 75 Se-6-selenocholesterol which was compared with 131 I-19-iodocholesterol [fr

  20. 99m-Tc-IDA scintigraphic demonstrability of biliary elements and liver function tests in hepatobiliary diseases

    International Nuclear Information System (INIS)

    Kim, C.Y.; Bahk, Y.W.

    1982-01-01

    In the present communication, the results will be reported on a clinical study of how well scintigraphic visualization of the hepatobiliary elements and several commonly used clinical liver function tests correlate each other in various diseases of the hepatobiliary system. The demonstrability of the biliary tract, gallblader (GB) and duodenum was rather closely paralleled to serum bilirubin level and less closely to alkaline phosphatase and rather poorly to SGOT and SGPT. The biliary tree could not be visualized scintigraphically when bilirubin exceeded 10 mg/dl

  1. A novel fully integrated handheld gamma camera

    International Nuclear Information System (INIS)

    Massari, R.; Ucci, A.; Campisi, C.; Scopinaro, F.; Soluri, A.

    2016-01-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  2. A novel fully integrated handheld gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Massari, R.; Ucci, A.; Campisi, C. [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy); Scopinaro, F. [University of Rome “La Sapienza”, S. Andrea Hospital, Rome (Italy); Soluri, A., E-mail: alessandro.soluri@ibb.cnr.it [Biostructure and Bioimaging Institute (IBB), National Research Council of Italy (CNR), Rome (Italy)

    2016-10-01

    In this paper, we present an innovative, fully integrated handheld gamma camera, namely designed to gather in the same device the gamma ray detector with the display and the embedded computing system. The low power consumption allows the prototype to be battery operated. To be useful in radioguided surgery, an intraoperative gamma camera must be very easy to handle since it must be moved to find a suitable view. Consequently, we have developed the first prototype of a fully integrated, compact and lightweight gamma camera for radiopharmaceuticals fast imaging. The device can operate without cables across the sterile field, so it may be easily used in the operating theater for radioguided surgery. The prototype proposed consists of a Silicon Photomultiplier (SiPM) array coupled with a proprietary scintillation structure based on CsI(Tl) crystals. To read the SiPM output signals, we have developed a very low power readout electronics and a dedicated analog to digital conversion system. One of the most critical aspects we faced designing the prototype was the low power consumption, which is mandatory to develop a battery operated device. We have applied this detection device in the lymphoscintigraphy technique (sentinel lymph node mapping) comparing the results obtained with those of a commercial gamma camera (Philips SKYLight). The results obtained confirm a rapid response of the device and an adequate spatial resolution for the use in the scintigraphic imaging. This work confirms the feasibility of a small gamma camera with an integrated display. This device is designed for radioguided surgery and small organ imaging, but it could be easily combined into surgical navigation systems.

  3. Scintigraphic imaging of endocrine organs

    International Nuclear Information System (INIS)

    Gross, M.D.; Shapiro, B.; Thrall, J.H.; Freitas, J.E.; Beierwaltes, W.H.

    1984-01-01

    The nuclear medicine approach to the portrayal of endocrine organs is unique; the scintigraphic images provide not only anatomic and localization information, but in many instances allow a quantitative assessment of organ function. The ability to image endocrine glands is based upon the design of radionuclides and radiopharmaceuticals with characteristics to take advantage of many unique and specific biochemical and advantage of many unique and specific biochemical and metabolic functions of these tissues. The recent introduction of new radiopharmaceutical and tracers has provided the consulting endocrinologist with imaging procedures that allow localization and functional characterization not available by other single, noninvasive diagnostic modalities. This review will serve as an update of the available techniques to image and quantitate the function of the endocrine glands using the nuclear medicine approach

  4. GRABGAM Analysis of Ultra-Low-Level HPGe Gamma Spectra

    International Nuclear Information System (INIS)

    Winn, W.G.

    1999-01-01

    The GRABGAM code has been used successfully for ultra-low level HPGe gamma spectrometry analysis since its development in 1985 at Savannah River Technology Center (SRTC). Although numerous gamma analysis codes existed at that time, reviews of institutional and commercial codes indicated that none addressed all features that were desired by SRTC. Furthermore, it was recognized that development of an in-house code would better facilitate future evolution of the code to address SRTC needs based on experience with low-level spectra. GRABGAM derives its name from Gamma Ray Analysis BASIC Generated At MCA/PC

  5. GRABGAM Analysis of Ultra-Low-Level HPGe Gamma Spectra

    Energy Technology Data Exchange (ETDEWEB)

    Winn, W.G.

    1999-07-28

    The GRABGAM code has been used successfully for ultra-low level HPGe gamma spectrometry analysis since its development in 1985 at Savannah River Technology Center (SRTC). Although numerous gamma analysis codes existed at that time, reviews of institutional and commercial codes indicated that none addressed all features that were desired by SRTC. Furthermore, it was recognized that development of an in-house code would better facilitate future evolution of the code to address SRTC needs based on experience with low-level spectra. GRABGAM derives its name from Gamma Ray Analysis BASIC Generated At MCA/PC.

  6. Development of a novel gamma probe for detecting radiation direction

    Science.gov (United States)

    Pani, R.; Pellegrini, R.; Cinti, M. N.; Longo, M.; Donnarumma, R.; D'Alessio, A.; Borrazzo, C.; Pergola, A.; Ridolfi, S.; De Vincentis, G.

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security.

  7. Development of a novel gamma probe for detecting radiation direction

    International Nuclear Information System (INIS)

    Pani, R.; Pellegrini, R.; Cinti, M.N.; Longo, M.; Donnarumma, R.; Borrazzo, C.; D'Alessio, A.; Pergola, A.; Ridolfi, S.; Vincentis, G. De

    2016-01-01

    Spatial localization of radioactive sources is currently a main issue interesting different fields, including nuclear industry, homeland security as well as medical imaging. It is currently achieved using different systems, but the development of technologies for detecting and characterizing radiation is becoming important especially in medical imaging. In this latter field, radiation detection probes have long been used to guide surgery, thanks to their ability to localize and quantify radiopharmaceutical uptake even deep in tissue. Radiolabelled colloid is injected into, or near to, the tumor and the surgeon uses a hand-held radiation detector, the gamma probe, to identify lymph nodes with radiopharmaceutical uptkake. The present work refers to a novel scintigraphic goniometric probe to identify gamma radiation and its direction. The probe incorporates several scintillation crystals joined together in a particular configuration to provide data related to the position of a gamma source. The main technical characteristics of the gamma locator prototype, i.e. sensitivity, spatial resolution and detection efficiency, are investigated. Moreover, the development of a specific procedure applied to the images permits to retrieve the source position with high precision with respect to the currently used gamma probes. The presented device shows a high sensitivity and efficiency to identify gamma radiation taking a short time (from 30 to 60 s). Even though it was designed for applications in radio-guided surgery, it could be used for other purposes, as for example homeland security

  8. Role of intensity transformation function for enhancement of bone scintigraphic images.

    Science.gov (United States)

    Pandey, Anil Kumar; Dhiman, Vishali; Sharma, Akshima; ArunRaj, Sreedharan Thankarajan; Baghel, Vivek; Patel, Chetan; Sharma, Param Dev; Bal, Chandrasekhar; Kumar, Rakesh

    2018-03-29

    The bone scintigraphic image might exceed the dynamic range (the ratio between the highest and the lowest brightness a monitor is capable of displaying) of display monitor. In this case, a high intensity area, and loss of the details of other structures in the displayed image makes the clinical interpretation a challenging task. We have investigated the role of intensity transformation function for enhancement of these types of images. Methods: Forty high dynamic range bone scintigraphic images were processed using intensity transformation (IT) function. The IT function has two parameters: threshold and slope. Keeping the threshold equal to mean counts of the image, the value of slope was varied from 1 to 20. In-house application program written in MATLAB R2013b was used to process images. Twenty output images corresponding to one input image were visually inspected by two experienced nuclear medicine (NM) physicians to select diagnostic quality images, and from their selection the standardized slope (value of slope parameter) that produced maximum numbers of diagnostic images was determined. They also rated the image quality of input and output images (at standardized slope) on scale 1 to 5 [where 1 is for poor and 5 if for the excellent diagnostic quality]. Student's t-test was used to test the significance of difference between the mean image quality score assigned to input and processed images at significance level α = 0.05. Results: The application of IT functions with standardized parameters significantly improved the quality of high dynamic range bone scintigraphic images ( P enhancement. Copyright © 2018 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  9. Avascularity of the femoral head following intracapsular fracture: a comparative scintigraphic and bioptic study

    Energy Technology Data Exchange (ETDEWEB)

    Hoilund-Carlsen, P F; Widding, A; Uhrenholdt, A; Christoffersen, P; Grieff, J [Copenhagen Univ. (Denmark)

    1980-03-01

    Bioptic and scintigraphic methods of diagnosing avascular necrosis of the femoral head following intracapsular fracture of the femoral neck were compared. During operative treatment of patients, biospy samples of bone marrow were taken from the femoral head about 2 hours after the intravenous injection of sup(99m)Tc-Sn-pyrophosphate; histological examination of the biopsies were also performed. Scintigrams of the femoral head using sup(99m)Tc-pyrophosphate were performed 2 days, 7 days and 6 weeks post-operatively. The biopsies confirmed no morphological changes being apparent in the first few days. The biopsy samples indicated two groups of patients with either high or low activity in the femoral head. However, it was concluded that the use of bone-seeking radionuclides with this technique might be more reliable. Scintigraphic trends divided the patients into three groups, one with persistently normal, another with varying, and a third with decreased activity in the femoral head. It was concluded that very early scintigraphy is probably not the method of choice since the images were often difficult to interpret. For the present, assessment of the viability of the femoral head should rest upon scintigraphic examinations performed about 6 weeks or 3 months after the injury.

  10. Development of superior bone scintigraphic agent from a series of {sup 99m}Tc-labeled zoledronic acid derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jianguo [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China); Qiu Ling, E-mail: qiulingwx@gmail.com [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China); Cheng Wen [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China); Luo Shineng, E-mail: shineng914@yahoo.com.cn [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China); Xue Li; Zhang Shu [Key Laboratory of Nuclear Medicine, Ministry of Health, Jiangsu Key Laboratory of Molecular Nuclear Medicine, Jiangsu Institute of Nuclear Medicine, Wuxi 214063 (China)

    2012-05-15

    Two novel zoledronic acid (ZL) derivatives, 1-hydroxy-4-(1H-imidazol-1-yl)butane-1,1-diyldiphosphonic acid (IBDP) and 1-hydroxy-5-(1H-imidazol-1-yl)pentane-1,1-diyldiphosphonic acid (IPeDP), were prepared and labeled with the radionuclide technetium-99m in a high labeling yield. In vitro stabilities of these radiolabeled complexes were measured by the radio-HPLC analysis as a function of time, which showed excellent stability with the radiochemical purity of over 95% at 6 h post preparation. Their in vivo biological performances were evaluated and compared with those of {sup 99m}Tc-ZL and {sup 99m}Tc-MDP (methylenediphosphonic acid). The biodistribution in mice and scintigraphic images of the rabbit showed that the tracer agent {sup 99m}Tc-IPeDP had highly selective uptake in the skeletal system and rapid clearance from the blood and soft tissues and an excellent scintigraphic image can be obtained in a shorter time post injection with clear visualization of the skeleton and low soft tissue activity. These preclinical studies suggest that {sup 99m}Tc-IPeDP would be a novel superior bone scintigraphic agent. - Highlights: Black-Right-Pointing-Pointer Two novel diphosphonic acids were labeled with the {sup 99m}Tc in high labeling yield. Black-Right-Pointing-Pointer {sup 99m}Tc-IPeDP had high uptake in skeletal system and rapid clearance from blood. Black-Right-Pointing-Pointer {sup 99m}Tc-IPeDP reveals attractive biological features as superior bone scanning agent.

  11. Scintigraphic small intestinal transit time and defaecography in patients with J-pouch

    DEFF Research Database (Denmark)

    Kjær, Mie Dilling; Simonsen, Jane Angel; Hvidsten, Svend

    2015-01-01

    Objective methods for examination of pouch function are warranted for a better understanding of the functional result and treatment of dysfunction. The objective of this study was to evaluate the results of scintigraphic intestinal transit time and defaecography compared to the results of pouch...... function, mucosal condition and a questionnaire on quality of life (QoL). This cross-sectional study included 21 patients. Scintigraphic transit time and defaecography was determined with the use of Tc-99m. Pouch function was assessed by number of bowel movements, pouch volume, and continence. Pouch...... mucosal condition was evaluated by endoscopy and histology. Median transit time was 189 min (105–365). Median ejection fraction at defaecography (EF) was 49% (3–77) and 62% (17–98) after first and second defecation. Median pouch volume was 223 mL (100–360). A median daily stool frequency of nine (4...

  12. A comparison of methods of assessment of scintigraphic colon transit.

    Science.gov (United States)

    Freedman, Patricia Noel; Goldberg, Paul A; Fataar, Abdul Basier; Mann, Michael M

    2006-06-01

    There is no standard method of analysis of scintigraphic colonic transit investigation. This study was designed to compare 4 techniques. Sixteen subjects (median age, 37.5 y; range, 21-61 y), who had sustained a spinal cord injury more than a year before the study, were given a pancake labeled with 10-18 MBq of (111)In bound to resin beads to eat. Anterior and posterior images were acquired with a gamma-camera 3 h after the meal and then 3 times a day for the next 4 d. Seven regions of interest, outlining the ascending colon, hepatic flexure, transverse colon, splenic flexure, descending colon, rectosigmoid, and total abdominal activity at each time point, were drawn on the anterior and posterior images. The counts were decay corrected and the geometric mean (GM), for each region, at each time point calculated. The GM was used to calculate the percentage of the initial total abdominal activity in each region, at each time point. Colonic transit was assessed in 4 ways: (a) Three independent nuclear medicine physicians visually assessed transit on the analog images and classified subjects into 5 categories of colonic transit (rapid, intermediate, generalized delay, right-sided delay, or left-sided delay). (b) Parametric images were constructed from the percentage activity in each region at each time point. (c) The arrival and clearance times of the activity in the right and left colon were plotted as time-activity curves. (d) The geometric center of the distribution of the activity was calculated and plotted on a graph versus time. The results of these 4 methods were compared using an agreement matrix. Though simple to perform, the visual assessment was unreliable. The best agreement occurred between the parametric images and the arrival and clearance times of the activity in the right and left colon. The different methods of assessment do not produce uniform results. The best option for evaluating colonic transit appears to be a combination of the analog images

  13. Analysis of radionuclide mixtures by {alpha}-{gamma} and {beta}-{gamma} coincidences using a simple device; Analyse de melanges de radionucleides par un dispositif simple de coincidences {alpha}-{gamma} et {beta}-{gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Pottier, R; Berger, R [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Fontenay-aux-Roses, 92 (France)

    1966-06-01

    A procedure is described for the qualitative and quantitative spectrographic analysis of radioactive sources containing two alpha-gamma emitters having the same alpha energy or two beta-gamma emitters having the same gamma energy. The main apparatus is a multichannel pulse-height analyzer including a coincidence circuit. The principle of the method, the synoptic scheme, the electronic device, the type of sources, and the precautions to be taken or the corrections to take into account are reported. The results obtained in solving the three following problems are discussed as examples of applications of the method: analysis of {sup 241}Am in alpha-gamma sources containing {sup 238}Pu; analysis of {sup 237}Np in beta-gamma sources containing {sup 239}Pu; and analysis of {sup 106}Ru-{sup 106}Rh in beta-gamma sources containing {sup 95}Zr-{sup 95}Nb. (authors) [French] Dans ce. rapport, on presente une methode d'analyse spectrographique qualitative et quantitative de sources radioactives contenant deux emetteurs alpha-gamma de meme energie alpha et deux emetteurs beta-gamma de meme energie gamma. L'organe principal est un analyseur d'amplitude a 400 canaux comprenant un circuit de coincidence. On decrit le principe de la methode, le schema synoptique, l'appareillage, le type des sources, les precautions a prendre ou les corrections a faire. On discute les resultats obtenus dans la solution des trois problemes suivants traites a titre d'application de la methode: 1. analyse d'americium 241 en presence de plutonium 238; 2. analyse de neptunium 237 en presence de plutonium 239; 3. analyse de ruthenium 106-rhodium 106 en presence de zirconium 95-niobium 95. (auteurs)

  14. Study of gamma ray analysis software's. Application to activation analysis of geological samples

    International Nuclear Information System (INIS)

    Silva, Luiz Roberto Nogueira da

    1998-01-01

    A comparative evaluation of the gamma-ray analysis software VISPECT, in relation to two commercial gamma-ray analysis software packages, OMNIGAM (EG and G Ortec) and SAMPO 90 (Canberra) was performed. For this evaluation, artificial gamma ray spectra were created, presenting peaks of different intensities and located at four different regions of the spectrum. Multiplet peaks with equal and different intensities, but with different channel separations, were also created. The results obtained showed a good performance of VISPECT in detecting and analysing single and multiplet peaks of different intensities in the gamma-ray spectrum. Neutron activation analysis of the geological reference material GS-N (IWG-GIT) and of the granite G-94, used in a Proficiency Testing Trial of Analytical Geochemistry Laboratories, was also performed , in order to evaluate the VISEPCT software in the analysis of real samples. The results obtained by using VISPECT were as good or better than the ones obtained using the other programs. (author)

  15. Sample analysis using gamma ray induced fluorescent X-ray emission

    Energy Technology Data Exchange (ETDEWEB)

    Sood, B S; Allawadhi, K L; Gandhi, R; Batra, O P; Singh, N [Punjabi Univ., Patiala (India). Nuclear Science Labs.

    1983-01-01

    A non-destructive method for the analysis of materials using gamma ray-induced fluorescent x-ray emission has been developed. In this method, special preparation of very thin samples in which the absorption of the incident gamma rays and the emitted fluorescent x-rays is negligible, is not needed, and the absorption correction is determined experimentally. A suitable choice of the incident gamma ray energies is made to minimise enhancement effects through selective photoionization of the elements in the sample. The method is applied to the analysis of a typical sample of the soldering material using 279 keV and 59.5 keV gamma rays from /sup 203/Hg and /sup 241/Am radioactive sources respectively. The results of the analysis are found to agree well with those obtained from the chemical analysis.

  16. Pharyngeal transit time measured by scintigraphic and biomagnetic method; Tempo de transito faringeano medido atraves dos metodos cintilografico e biomagnetico

    Energy Technology Data Exchange (ETDEWEB)

    Miquelin, C.A.; Braga, F.J.H.N.; Baffa, O. [Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Dept. de Fisica; Dantas, R.O.; Oliveira, R.B. [Faculdade de Medicina de Ribeirao Preto, SP (Brazil)

    1996-12-31

    A comparative evaluation between scintigraphic and biomagnetic method to measure the pharyngeal transit is presented. Three volunteers have been studied. The aliment (yogurt) was labeled with {sup 9}9{sup m} Technetium for the scintigraphic test and with ferrite for the biomagnetic one. The preliminary results indicate a difference between the values obtained, probably due to the biomagnetic detector resolution 3 refs., 2 figs., 1 tab.

  17. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    were carried out. No significant differences between results obtained by the use of one or two scintigraphic projections were found. The between-subject coefficient of variation was 14% in the lower limb experiment and 11% in the upper limb experiment. The within-subject coefficient of variation was 6......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation...... of the lower limb and a mean reduction of 0.45+/-0.10 (2 SD) after half a minute of elevation of the upper limb. We conclude that the method is precise and can be used in investigating physiologic and pathophysiologic mechanisms in relation to blood volumes of limbs not subject to research previously....

  18. An optimum analysis sequence for environmental gamma-ray spectrometry

    International Nuclear Information System (INIS)

    De la Torre, F.; Rios M, C.; Ruvalcaba A, M. G.; Mireles G, F.; Saucedo A, S.; Davila R, I.; Pinedo, J. L.

    2010-10-01

    This work aims to obtain an optimum analysis sequence for environmental gamma-ray spectroscopy by means of Genie 2000 (Canberra). Twenty different analysis sequences were customized using different peak area percentages and different algorithms for: 1) peak finding, and 2) peak area determination, and with or without the use of a library -based on evaluated nuclear data- of common gamma-ray emitters in environmental samples. The use of an optimum analysis sequence with certified nuclear information avoids the problems originated by the significant variations in out-of-date nuclear parameters of commercial software libraries. Interference-free gamma ray energies with absolute emission probabilities greater than 3.75% were included in the customized library. The gamma-ray spectroscopy system (based on a Ge Re-3522 Canberra detector) was calibrated both in energy and shape by means of the IAEA-2002 reference spectra for software intercomparison. To test the performance of the analysis sequences, the IAEA-2002 reference spectrum was used. The z-score and the reduced χ 2 criteria were used to determine the optimum analysis sequence. The results show an appreciable variation in the peak area determinations and their corresponding uncertainties. Particularly, the combination of second derivative peak locate with simple peak area integration algorithms provides the greater accuracy. Lower accuracy comes from the combination of library directed peak locate algorithm and Genie's Gamma-M peak area determination. (Author)

  19. Scintigraphic examinations after stent implantation in central airways

    International Nuclear Information System (INIS)

    Richter, W.S.; Kettner, B.I.; Munz, D.L.

    1998-01-01

    Endotracheal and endobronchial stent implantation has been developed as an effective treatment of benign and malignant airway stenosis and of tracheo- or bronchoesophageal fistulas. The selection of the stent type depends on the kind and site of disease. Chest X-ray and bronchoscopy are the procedures of choice for monitoring of stent position, structure, and function. However, with scintigraphic methods the effects of stent implantation on pulmonary ventilation and perfusion can be assessed non-invasively. The validation of the effect of a stent implantation on mucociliary and tussive clearance remains to be elucidated. (orig.) [de

  20. Liver scintigraphic features associated with alcoholism

    International Nuclear Information System (INIS)

    Drum, D.E.; Beard, J.O.

    1978-01-01

    The relationships between scintigraphic features and clinical alcoholism were studied by review of 2406 liver scintiphotos. Two distinct patterns were significantly associated with alcoholism: heterogeneous distribution of radiocolloid in the liver, and jointly increased uptake of tracer by the spleen and vertebral bone marrow. A total of 13 overall patterns were found to distinguish, with considerable reliability, alcoholics from all other patients. This finding reflects the frequency with which alcohol abuse is associated with hepatic dysfunction in hospital patients. These observations indicate an important role for the nuclear medicine physician in detection of alcoholism among patients referred for liver-spleen imaging, and they form a basis for comparison with the diagnostic efficacy of other methods of evaluating diffuse liver diseases

  1. Preliminary results on scintigraphic evaluation of malignant external otitis

    International Nuclear Information System (INIS)

    Malamitsi, J.; Maragoudakis, P.; Papafragou, K.; Koukouliou, V.; Kalatzis, Y.; Adamopoulos, G.; Proukakis, C.

    1993-01-01

    Malignant external otitis (MEO) is a potentially fatal otitis occurring in diabetic and immunosuppressed patients, which may cause cranial nerve palsies and massive thrombophlebitis of the brain. We studied five diabetic patients with the clinical diagnosis of external otitis who were suspected of having MEO and one diabetic patient presumed cured from MEO. All of them underwent methylene diphosphonate, nanocolloid and gallium single-photon emission tomography studies with quantitative analysis on the basis of regions of interest and count profile curves. This combined assessment helped us to diagnose and follow-up soft tissue and temporal bone infection, especially in the case of transsphenoidal extension of the disease, since conventional radiology and computed tomography were of no particular help. On the basis of these results, we consider scintigraphic demonstration of skull base infection as a fourth criterion of MEO given that the classical Chandler's triad (diabetes, granuloma, and Pseudomonas aeruginosa) is not always present. (orig.)

  2. Neutron-gamma discrimination by pulse analysis with superheated drop detector

    International Nuclear Information System (INIS)

    Das, Mala; Seth, S.; Saha, S.; Bhattacharya, S.; Bhattacharjee, P.

    2010-01-01

    Superheated drop detector (SDD) consisting of drops of superheated liquid of halocarbon is irradiated to neutrons and gamma-rays from 252 Cf fission neutron source and 137 Cs gamma source, respectively, separately. Analysis of pulse height of signals at the neutron and gamma-ray sensitive temperature provides significant information on the identification of neutron and gamma-ray induced events.

  3. Tables of nuclear constants for gamma activation analysis

    International Nuclear Information System (INIS)

    Randa, Z.; Kreisinger, F.

    1980-01-01

    The tables of photonuclear reactions presented, designed for gamma activation analysis, list accurate data on energy of photons emitted by radionuclides, gamma line intensity, half-lives, photonuclear reactions, or the genetic relationship leading to the formation of the given radionuclide together with the respective reaction thresholds. They also list natural isotopic occurrence of the individual target nuclides. The tables are arranged by increasing atomic numbers of newly formed radionuclides and by increasing gamma energies. (B.S.)

  4. An optimum analysis sequence for environmental gamma-ray spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    De la Torre, F.; Rios M, C.; Ruvalcaba A, M. G.; Mireles G, F.; Saucedo A, S.; Davila R, I.; Pinedo, J. L., E-mail: fta777@hotmail.co [Universidad Autonoma de Zacatecas, Centro Regional de Estudis Nucleares, Calle Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2010-10-15

    This work aims to obtain an optimum analysis sequence for environmental gamma-ray spectroscopy by means of Genie 2000 (Canberra). Twenty different analysis sequences were customized using different peak area percentages and different algorithms for: 1) peak finding, and 2) peak area determination, and with or without the use of a library -based on evaluated nuclear data- of common gamma-ray emitters in environmental samples. The use of an optimum analysis sequence with certified nuclear information avoids the problems originated by the significant variations in out-of-date nuclear parameters of commercial software libraries. Interference-free gamma ray energies with absolute emission probabilities greater than 3.75% were included in the customized library. The gamma-ray spectroscopy system (based on a Ge Re-3522 Canberra detector) was calibrated both in energy and shape by means of the IAEA-2002 reference spectra for software intercomparison. To test the performance of the analysis sequences, the IAEA-2002 reference spectrum was used. The z-score and the reduced {chi}{sup 2} criteria were used to determine the optimum analysis sequence. The results show an appreciable variation in the peak area determinations and their corresponding uncertainties. Particularly, the combination of second derivative peak locate with simple peak area integration algorithms provides the greater accuracy. Lower accuracy comes from the combination of library directed peak locate algorithm and Genie's Gamma-M peak area determination. (Author)

  5. Temporal functional analysis of dynamic scintigraphy by application of the Karhunen-Loeve transform

    International Nuclear Information System (INIS)

    Girardot-Verdenet, Josette.

    1981-01-01

    Four main themes are dealt with in four different chapters. The first describes the scintigraphic data acquisition system: gamma camera and computer, as well as the various types of examination performed. Chapter two develops the subject of image processing techniques, especially as applied to kidney and heart scintigraphs which cover all problems encountered by doctors in the interpretation of a dynamic scintigraph. Chapter three is devoted to the formalism of Karhunen-Loeve transformation, the method best suited for data sorting because alone able to achieve a compression of this data in the sense of the mean quadratic error. The method is applied in chapter four to obtain functional heart and kidney images. The demarcation of the outlines of organs is often imprecise and two neighbouring zones developing at different rates have been differentiated by application of the Fukunaga-Koontz transformation which uses the properties of the Kahrunen-Loeve transformation in the case of heart scintigraphy where ventricles and auricles are superimposed. The aim of this work is to find out whether the compression of data for the Kahrunen-Loeve transformation provides any objective elements in the interpretation of dynamic scintigraphs [fr

  6. Red gold analysis by using gamma absorption tchnique

    International Nuclear Information System (INIS)

    Kurtoglu, A.; Tugrul, A.B.

    2001-01-01

    Gold is a valuable metal and also preferable materials for antique artefacts and some advanced technology products. It can be offered for the analysis of the gold as namely; neutron activation analysis, X-ray florescence technique, Auger spectroscopy, atomic absorption and wet chemistry. Some limitations exist in practice for these techniques, especially in the points of financial and applicability concepts. An advanced a practical technique is gamma absorption technique for the gold alloys. This technique is based on discontinuities in the absorption coefficient for gamma rays at corresponding to the electronic binding energies of the absorber. If irradiation is occurred at gamma absorption energy for gold, absorption rates of the red gold changes via the gold amounts in the alloy. Red gold is a basic and generally preferable alloy that has copper and silver additional of the gold in it. The gold amount defines as carat of the gold. Experimental studies were observed for four different carats of red gold; these are 8, 14, 18 and 22 carats. K-edge energy level of the gold is on 80 keV energy. So, Ba-133 radioisotope is preferred as the gamma source because of it has gamma energy peak in that energy. Experiments observed in the same geometry for all samples. NaI(Tl) detector and multichannel analyser were used for measurements. As a result of the experiments, the calibration curves could be drawn for red gold. For examine this curve, unknown samples are measured in experimental set and it can be determined the carat of it with the acceptability. So the red gold analysis can be observed non-destructively, easily and quickly by using the gamma absorption technique

  7. Hepatic Scintigraphic Findings of Budd-Chiari Syndrome due to Inferior Vena Caval Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Chung, Soo Kyo; Byun, Jae Young; Lee, Sung Yong; Shinn, Kyung Sub; Kim, Choon Yul; Bahk, Yong Whee [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1988-03-15

    Budd-Chiari syndrome (BCS) is a rare clinical entity characterized by post-sinusoidal portal hypertension caused by the obstruction to the hepatic vein outflow. The diagnosis is suggested by hepatic scintigraphy and is usually confirmed by hepatic venography, inferior vena cavography and biopsy. The scintigraphic finding of BCS caused by the obstruction of main hepatic vein has been reported to consist typically of hypertrophy of the caudate lobe with increased radionuclide accumulation. Such a typical finding has been accounted for by the fact that the venous outflow from the caudate lobe is preserved when the main hepatic vein is obstructed. But usually, the hepatic venous outflow from the caudate lobe is also obstructed in BCS due to inferior vena caval obstruction. So hepatic scintigraphic findings of BCS due to inferior vena caval obstruction show different findings as compared with the BCS due to hepatic vein obstruction. We evaluate the hepatic scintigrams of the 13 cases of BCS due to inferior vena caval obstruction and review the literatures. The results are as follows: 1) We cannot observe the caudate lobe hypertrophy with increased uptake, which is known as a classic finding in BCS due to hepatic vein obstruction. 2) The most prominent hepatic scintigraphic findings of BCS are nonhomogenous uptake in the liver with extrahepatic uptake in the all cases. 3) We can see cold areas at the superior aspect of right hepatic lobe in 7 cases (54%). This is a useful finding suggesting BCS due to inferior vena caval obstruction.

  8. Hepatic Scintigraphic Findings of Budd-Chiari Syndrome due to Inferior Vena Caval Obstruction

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chung, Soo Kyo; Byun, Jae Young; Lee, Sung Yong; Shinn, Kyung Sub; Kim, Choon Yul; Bahk, Yong Whee

    1988-01-01

    Budd-Chiari syndrome (BCS) is a rare clinical entity characterized by post-sinusoidal portal hypertension caused by the obstruction to the hepatic vein outflow. The diagnosis is suggested by hepatic scintigraphy and is usually confirmed by hepatic venography, inferior vena cavography and biopsy. The scintigraphic finding of BCS caused by the obstruction of main hepatic vein has been reported to consist typically of hypertrophy of the caudate lobe with increased radionuclide accumulation. Such a typical finding has been accounted for by the fact that the venous outflow from the caudate lobe is preserved when the main hepatic vein is obstructed. But usually, the hepatic venous outflow from the caudate lobe is also obstructed in BCS due to inferior vena caval obstruction. So hepatic scintigraphic findings of BCS due to inferior vena caval obstruction show different findings as compared with the BCS due to hepatic vein obstruction. We evaluate the hepatic scintigrams of the 13 cases of BCS due to inferior vena caval obstruction and review the literatures. The results are as follows: 1) We cannot observe the caudate lobe hypertrophy with increased uptake, which is known as a classic finding in BCS due to hepatic vein obstruction. 2) The most prominent hepatic scintigraphic findings of BCS are nonhomogenous uptake in the liver with extrahepatic uptake in the all cases. 3) We can see cold areas at the superior aspect of right hepatic lobe in 7 cases (54%). This is a useful finding suggesting BCS due to inferior vena caval obstruction.

  9. Scintigraphic images of bacterial infection using aptamers directly labeled with 99mTc

    International Nuclear Information System (INIS)

    Santos, S.R.; Correa, C.R.; Andrade, A.S.R.; Barros, A.L.B.; Diniz, S.O.F.; Cardoso, V.N.

    2015-01-01

    Staphylococcus aureus is specie of great medical importance and is the most commonly agent found in infections of soft tissues, bone infections and bone prostheses. In this study, aptamers selected to S. aureus were labeled by the direct method with 99m Tc and used for bacterial infection identification by scintigraphy. The radiolabeled aptamers radiochemical purity and stability were assessed by thin-layer chromatography (TLC). Three groups of Swiss mice (n=6) were used for the scintigraphic imaging studies. The first group was infected intramuscularly in the right thigh with S. aureus, the second group with C. albicans and the third group received zymosan to induce aseptic inflammation. After 24 h, radiolabeled aptamers (18 MBq) were injected by the tail vein. Scintigraphic images were acquired at 1 h and 4 h postinjection. The radiolabeling yield with 99m Tc was over 90%. The radiolabeled aptamers were stable in 0.9% saline, plasma and cysteine excess. The scintigraphic image profiles showed high uptake in the kidneys and bladder in all groups, indicating a main renal excretion consistent with the hydrophilic nature of the molecule. No accumulation of radioactivity was observed in the thyroid, stomach, liver and spleen, indicating acceptable levels of radiochemical impurities. The group infected with S. aureus showed a visible uptake in the infected right thigh at 1 h post-injection. For the control groups (C. albicans and zymosan) visible differences between the right and left thighs were not observed. The radiolabeled aptamers were able to distinguish aseptic inflammation from bacterial infection and bacterial from fungal infection. (author)

  10. Genomic sequences of murine gamma B- and gamma C-crystallin-encoding genes: promoter analysis and complete evolutionary pattern of mouse, rat and human gamma-crystallins.

    Science.gov (United States)

    Graw, J; Liebstein, A; Pietrowski, D; Schmitt-John, T; Werner, T

    1993-12-22

    The murine genes, gamma B-cry and gamma C-cry, encoding the gamma B- and gamma C-crystallins, were isolated from a genomic DNA library. The complete nucleotide (nt) sequences of both genes were determined from 661 and 711 bp, respectively, upstream from the first exon to the corresponding polyadenylation sites, comprising more than 2650 and 2890 bp, respectively. The new sequences were compared to the partial cDNA sequences available for the murine gamma B-cry and gamma C-cry, as well as to the corresponding genomic sequences from rat and man, at both the nt and predicted amino acid (aa) sequence levels. In the gamma B-cry promoter region, a canonical CCAAT-box, a TATA-box, putative NF-I and C/EBP sites were detected. An R-repeat is inserted 366 bp upstream from the transcription start point. In contrast, the gamma C-cry promoter does not contain a CCAAT-box, but some other putative binding sites for transcription factors (AP-2, UBP-1, LBP-1) were located by computer analysis. The promoter regions of all six gamma-cry from mouse, rat and human, except human psi gamma F-cry, were analyzed for common sequence elements. A complex sequence element of about 70-80 bp was found in the proximal promoter, which contains a gamma-cry-specific and almost invariant sequence (crygpel) of 14 nt, and ends with the also invariant TATA-box. Within the complex sequence element, a minimum of three further features specific for the gamma A-, gamma B- and gamma D/E/F-cry genes can be defined, at least two of which were recently shown to be functional. In addition to these four sequence elements, a subtype-specific structure of inverted repeats with different-sized spacers can be deduced from the multiple sequence alignment. A phylogenetic analysis based on the promoter region, as well as the complete exon 3 of all gamma-cry from mouse, rat and man, suggests separation of only five gamma-cry subtypes (gamma A-, gamma B-, gamma C-, gamma D- and gamma E/F-cry) prior to species separation.

  11. Computer processing of dynamic scintigraphic studies

    International Nuclear Information System (INIS)

    Ullmann, V.

    1985-01-01

    The methods are discussed of the computer processing of dynamic scintigraphic studies which were developed, studied or implemented by the authors within research task no. 30-02-03 in nuclear medicine within the five year plan 1981 to 85. This was mainly the method of computer processing radionuclide angiography, phase radioventriculography, regional lung ventilation, dynamic sequential scintigraphy of kidneys and radionuclide uroflowmetry. The problems are discussed of the automatic definition of fields of interest, the methodology of absolute volumes of the heart chamber in radionuclide cardiology, the design and uses are described of the multipurpose dynamic phantom of heart activity for radionuclide angiocardiography and ventriculography developed within the said research task. All methods are documented with many figures showing typical clinical (normal and pathological) and phantom measurements. (V.U.)

  12. Fast renal trapping of porcine Luteinizing Hormone (pLH shown by 123I-scintigraphic imaging in rats explains its short circulatory half-life

    Directory of Open Access Journals (Sweden)

    Locatelli Alain

    2003-10-01

    Full Text Available Abstract Background Sugar moieties of gonadotropins play no primary role in receptor binding but they strongly affect their circulatory half-life and consequently their in vivo biopotencies. In order to relate more precisely hepatic trapping of these glycoproteic hormones with their circulatory half-life, we undertook a comparative study of the distribution and elimination of porcine LH (pLH and equine CG (eCG which exhibit respectively a short and a long half-life. This was done first by following half-lives of pLH in piglets with hepatic portal circulation shunted or not. It was expected that such a shunt would enhance the short half-life of pLH. Subsequently, scintigraphic imaging of both 123I-pLH and 123I-eCG was performed in intact rats to compare their routes and rates of distribution and elimination. Methods Native pLH or eCG was injected to normal piglets and pLH was tested in liver-shunted anæsthetized piglet. Blood samples were recovered sequentially over one hour time and the hormone concentrations were determined by a specific ELISA method. Scintigraphic imaging of 123I-pLH and 123I-eCG was performed in rats using a OPTI-CGR gamma camera. Results In liver-shunted piglets, the half-life of pLH was found to be as short as in intact piglets (5 min. In the rat, the half-life of pLH was also found to be very short (3–6 min and 123I-pLH was found to accumulate in high quantity in less than 10 min post injection at the level of kidneys but not in the liver. 123I-eCG didn't accumulate in any organ in the rats during the first hour, plasma concentrations of this gonadotropin being still elevated (80% at this time. Conclusion In both the porcine and rat species, the liver is not responsible for the rapid elimination of pLH from the circulation compared to eCG. Our scintigraphic experiments suggest that the very short circulatory half-life of LH is due to rapid renal trapping.

  13. Scintigraphic scoring system for grading severity of gastro-esophageal reflux on 99mTc sulfur colloid gastro-esophageal reflux scintigraphy: a prospective study of 39 cases with pre and post treatment assessment

    International Nuclear Information System (INIS)

    Puranik, Ameya D.; Nair, Gopinathan; Bandyopadhyay, Abhijit; Shinto, Ajit; Zade, Anand; Aggarwal, Rajiv

    2013-01-01

    The study aimed at developing a scoring system for scintigraphic grading of gastro-esophageal reflux (GER), on gastro-esophageal reflux scintigraphy (GERS) and comparison of clinical and scintigraphic scores, pre- and post-treatment. A total of 39 cases with clinically symptomatic GER underwent 99m Tc sulfur colloid GERS; scores were assigned based on the clinical and scintigraphic parameters. Post domperidone GERS was performed after completion of treatment. Follow up GERS was performed and clinical and scintigraphic parameters were compared with baseline parameters. Paired t-test on pre and post domperidone treatment clinical scores showed that the decline in post-treatment scores was highly significant, with P value < 0.001. The scintigraphic scoring system had a sensitivity of 93.9% in assessing treatment response to domperidone, specificity of 83.3% i.e., 83.3% of children with no decline in scintigraphic scores show no clinical response to Domperidone. The scintigraphic scoring system had a positive predictive value of 96.9% and a negative predictive value of 71.4%. GERS with its quantitative parameters is a good investigation for assessing the severity of reflux and also for following children post-treatment. (author)

  14. Evaluation of radionuclide calibrators and scintigraphic cameras used in nuclear medicine in the Sergipe

    International Nuclear Information System (INIS)

    Lima Ferreira, F.C.; Nascimento Souza, D. do

    2008-01-01

    A quality control program to nuclear medicine services concerns the verification of the efficiency of equipment used to diagnosis and treatment, allow the professional improvement. In this study were assessed the performance of two radionuclide calibrators (activimeters) and of two scintigraphic cameras employed in nuclear medicine in the state of Sergipe, Brazil, according to regulation CNEN -NN-3.05. Additionally, to the radionuclide calibrators it was established a nd characterized an intercomparison of activities measured by different practitioners from standard samples of sealed radioactive sources of 133 Ba and 57 Co. The evaluation of this manufacture object was made thought quality control tests on scintigraphic cameras, such as: test of spatial resolution, tomographic resolution and linearity. The results of the quality control tests were satisfactory and they one can be used as parameter in future evaluations. (author)

  15. Scintigraphic detection of regional disruption of adrenergic neurons in the heart

    International Nuclear Information System (INIS)

    Sisson, J.C.; Lynch, J.J.; Johnson, J.; Jaques, S. Jr.; Wu, D.; Bolgos, G.; Lucchesi, B.R.; Wieland, D.M.

    1988-01-01

    Experiments were designed to detect regional disruptions of adrenergic neurons in the hearts of living dogs. The neuron disruption was achieved by the application of phenol to the epicardium of the left ventricle. Evidence for denervation was the reduction in endogenous norepinephrine (NE) concentrations in the myocardium beneath the region of phenol treatment and toward the apex. Radiolabeled meta-iodobenzylguanidine (MIBG) acts as an analog of NE and as such is concentrated in adrenergic nerve terminals. Following phenol application, MIBG labeled with 125 I was found, 20 hours after injection, to be distributed within myocardium in patterns comparable to those of NE. However, left stellectomy did not alter the distributions of NE or 125 I-MIBG in the myocardium and apparently did not disrupt adrenergic innervation. MIBG labeled with 123 I enabled scintigraphic images of heart neurons in the living dog 3 and 20 hours after injection; these images portrayed the regions of adrenergic neuron disruption caused by phenol treatment. Concentrations of thallium-201 depicted on scintigraphic image and of triphenyltetrazolium observed on in vitro staining demonstrated no myocardial injury. Thus, scintigraphy with 123 I-MIBG will display regional adrenergic denervations in the heart

  16. Scintigraphic investigation of sacroiliac disease

    International Nuclear Information System (INIS)

    Lentle, B.C.; Russell, A.S.; Percy, J.S.; Jackson, F.I.

    1977-01-01

    Bone scintigraphs obtained with both technetium-99m polyphosphate and technetium-99m pyrophosphate have been abnormal at the sacroiliac joints of 44 patients with definite ankylosing spondylitis (AS). Because of the normal registration of the sacroiliac joints on bone scintigraphy, it has been necessary to develop a profile-scan technique to quantify the abnormality that proves to be significantly different from the normal finding. In 17 patients with a strong clinical suspicion of AS but normal radiographs, the sacroiliac joints have frequently been abnormal. This finding is meaningful because there is a common occurrence in this group of the histocompatibility antigen HL A-B27, known to be a marker of AS. We also note the frequency of abnormal sacroiliac scintigrams in 26 patients with rheumatoid arthritis and in a group of other diseases--Crohn's disease, uveitis, psoriasis, ulcerative colitis, and Reiters' disease--all of which share some of the manifestations of AS

  17. Hyper-functioning Thyroid Nodule with Scintigraphic Owl's Eye Appearance

    International Nuclear Information System (INIS)

    Al-Kordi, R.S.; Elgazzar, A.H.

    2006-01-01

    Hyper-functioning thyroid nodules may produce various scintigraphic appearances on thyroid scans. Autonomously hyper functioning thyroid nodules invariably demonstrate degenerative changes. These changes may give rise to central or less commonly peripheral photopenic areas on a thyroid scan within otherwise a hot nodule. In this report we present a case of hyper functioning autonomous nodule with peripheral degeneration and residual central functioning tissue giving the appearance of an owl's eye. Although rare, this pattern can be seen in a variety of benign and malignant thyroid conditions. (author)

  18. Evaluation by scintigraphic images of musculoskeletal infection with 99mTc ciprofloxacin

    International Nuclear Information System (INIS)

    Casacó, C.A.; Hernández, A.; Perera, A.; Prats, A.; Batista, J.F.; Torres, L.A.; Quesada, R.; Sánchez, Y.; Valladares, L.; Sánchez, E.L.; Marrero, L.O.; Mustelier, E.

    2016-01-01

    Introduction: Infectious diseases present high morbidity and mortality in all countries, especially in the third world. In Cuba between 2005 and 2014, approximately 1.3% of the total deaths were killed. Orthopedic infections are among the most common. The scintigraphic methods currently used are not able to discern between a septic focus and a sterile inflammation. Radiological methods detect a bone infection only when there is significant anatomical damage. Ciprofloxacin as a drug binds and inhibits topoisomerase II or bacterial gyrase DNA. Objective: to evaluate the efficacy of 99m Tc-ciprofloxacin in the detection of osteo-articular bacterial processes. Materials and Methods: An experimental, cross-sectional, cross-sectional study was conducted involving 258 patients with suspected osteoarticular infectious processes. The presence of the lesion and the quantification and intensity of uptake in the foci of infection in images with 99m Tc-MDP (3h post-administration) and 99m Tc-ciprofloxacin (1, 4 and 24h post-administration) were visually determined. Studies of 99m Tc-ciprofloxacin were compared with Culture / Biopsy results. Results: The germ that most frequently appears in infected osteo-articular sites is staphilococcusaureus. No adverse effects were detected in any of the subjects studied. Studies with 99m Tc-MDP allow delineating infected areas but are not specific. 99mTc-ciprofloxacin shows the sites of active osteo-articular bacterial infection and when it is fixed in a septic focus gives intense captures at both 4 and 24 hours. It exhibits a sensitivity similar to 99mTc-MDP, but a significantly higher specificity. Conclusions: Scintigraphic images with 99m Tc-ciprofloxacin show sites of active osteo-articular bacterial infection with a specificity significantly higher than 99m Tc-MDP. The microbiological and scintigraphic results were positive for sepsis in 122 patients out of 219 who were sampled.

  19. Contribution of different scintigraphic techniques to the management of medullary thyroid carcinoma

    International Nuclear Information System (INIS)

    Sandrock, D.; Blossey, H.C.; Steinroeder, M.; Munz, D.L.

    1989-01-01

    We compared three different scintigraphic techniques for the localization of neck recurrences and metastases in seven patients with medullary thyroid carcinoma one month to eight years after the first surgical intervention. Three successive scintigraphic studies were performed in five patients (6 x 3 studies) within two weeks using 201Tl chloride, 111In-labeled F(ab')2 fragments of the anti-carcinoembryonic antigen (anti-CEA) monoclonal antibody (MoAb) BW 431/31, and 131I meta-iodo-benzylguanidine (MIBG). Additionally, 11 studies were performed with the 111In-labeled MoAb fragment BW 431/31 (seven studies) or the 99mTc-labeled intact anti-CEA MoAb BW 431/26 (four studies). The gold standards for classifying scintigraphic results were biopsy, histology, surgery, and cytology. Six regions were classified as positive or negative in each study: thyroid region, four quadrants (lymph node regions) around the thyroid, and the region of the upper mediastinum. Of 36 sites, 201Tl was true positive (TP) in seven sites, false-positive (FP) in one site, true negative (TN) in 22 sites, and false-negative (FN) in six sites, resulting in a sensitivity of 54% and a specificity of 96%. 131I MIBG was TP in four sites, FP in none of the sites, TN in 23 sites, and FN in nine sites, with a sensitivity of 31% and a specificity of 100%. Immunoscintigraphy (102 sites overall) was TP in 16 sites, FP in five sites, TN in 77 sites, and FN in four sites, resulting in a sensitivity of 80% and a specificity of 94%. Immunoscintigraphy with 111In/99mTc anti-CEA F(ab')2 fragment/intact antibody is superior to scintigraphy with 201Tl and 131I MIBG

  20. Gold analysis by the gamma absorption technique

    International Nuclear Information System (INIS)

    Kurtoglu, Arzu; Tugrul, A.B.

    2003-01-01

    Gold (Au) analyses are generally performed using destructive techniques. In this study, the Gamma Absorption Technique has been employed for gold analysis. A series of different gold alloys of known gold content were analysed and a calibration curve was obtained. This curve was then used for the analysis of unknown samples. Gold analyses can be made non-destructively, easily and quickly by the gamma absorption technique. The mass attenuation coefficients of the alloys were measured around the K-shell absorption edge of Au. Theoretical mass attenuation coefficient values were obtained using the WinXCom program and comparison of the experimental results with the theoretical values showed generally good and acceptable agreement

  1. A tool to include gamma analysis software into a quality assurance program.

    Science.gov (United States)

    Agnew, Christina E; McGarry, Conor K

    2016-03-01

    To provide a tool to enable gamma analysis software algorithms to be included in a quality assurance (QA) program. Four image sets were created comprising two geometric images to independently test the distance to agreement (DTA) and dose difference (DD) elements of the gamma algorithm, a clinical step and shoot IMRT field and a clinical VMAT arc. The images were analysed using global and local gamma analysis with 2 in-house and 8 commercially available software encompassing 15 software versions. The effect of image resolution on gamma pass rates was also investigated. All but one software accurately calculated the gamma passing rate for the geometric images. Variation in global gamma passing rates of 1% at 3%/3mm and over 2% at 1%/1mm was measured between software and software versions with analysis of appropriately sampled images. This study provides a suite of test images and the gamma pass rates achieved for a selection of commercially available software. This image suite will enable validation of gamma analysis software within a QA program and provide a frame of reference by which to compare results reported in the literature from various manufacturers and software versions. Copyright © 2015. Published by Elsevier Ireland Ltd.

  2. 3D segmentation of scintigraphic images with validation on realistic GATE simulations

    International Nuclear Information System (INIS)

    Burg, Samuel

    2011-01-01

    The objective of this thesis was to propose a new 3D segmentation method for scintigraphic imaging. The first part of the work was to simulate 3D volumes with known ground truth in order to validate a segmentation method over other. Monte-Carlo simulations were performed using the GATE software (Geant4 Application for Emission Tomography). For this, we characterized and modeled the gamma camera 'γ Imager' Biospace"T"M by comparing each measurement from a simulated acquisition to his real equivalent. The 'low level' segmentation tool that we have developed is based on a modeling of the levels of the image by probabilistic mixtures. Parameters estimation is done by an SEM algorithm (Stochastic Expectation Maximization). The 3D volume segmentation is achieved by an ICM algorithm (Iterative Conditional Mode). We compared the segmentation based on Gaussian and Poisson mixtures to segmentation by thresholding on the simulated volumes. This showed the relevance of the segmentations obtained using probabilistic mixtures, especially those obtained with Poisson mixtures. Those one has been used to segment real "1"8FDG PET images of the brain and to compute descriptive statistics of the different tissues. In order to obtain a 'high level' segmentation method and find anatomical structures (necrotic part or active part of a tumor, for example), we proposed a process based on the point processes formalism. A feasibility study has yielded very encouraging results. (author) [fr

  3. Gamma model and its analysis for phase measuring profilometry.

    Science.gov (United States)

    Liu, Kai; Wang, Yongchang; Lau, Daniel L; Hao, Qi; Hassebrook, Laurence G

    2010-03-01

    Phase measuring profilometry is a method of structured light illumination whose three-dimensional reconstructions are susceptible to error from nonunitary gamma in the associated optical devices. While the effects of this distortion diminish with an increasing number of employed phase-shifted patterns, gamma distortion may be unavoidable in real-time systems where the number of projected patterns is limited by the presence of target motion. A mathematical model is developed for predicting the effects of nonunitary gamma on phase measuring profilometry, while also introducing an accurate gamma calibration method and two strategies for minimizing gamma's effect on phase determination. These phase correction strategies include phase corrections with and without gamma calibration. With the reduction in noise, for three-step phase measuring profilometry, analysis of the root mean squared error of the corrected phase will show a 60x reduction in phase error when the proposed gamma calibration is performed versus 33x reduction without calibration.

  4. Scintigraphic colonic transit study in children with chronic constipation

    International Nuclear Information System (INIS)

    Yano, Tsunehiro; Uemura, Sadashige; Nakaoka, Tatsuo; Nakagawa, Yoshikiyo; Tanimoto, Terutaka; Sone, Teruki

    2008-01-01

    Chronic constipation can be caused either by slow colonic transit or by functional fecal retention. The treatment strategy for chronic constipation should be based on its etiology. Scintigraphic colonic transit study (SCTS) is useful for dividing the cause of the constipation into slow colonic transit and functional fecal retention. SCTS is also useful for judging the therapeutic effect and postoperative intestinal motility of Hirschsprung's disease, anorectal molformation, and others. As SCTS is a safe, simple, and painless examination, it is one of the most important examinations in evaluating chronic constipation. (author)

  5. An unusual scintigraphic pattern in sickle cell patients

    International Nuclear Information System (INIS)

    Glaser, A.M.; Chen, D.C.P.; Siegel, M.E.; Norris, S.L.; Haywood, L.J.

    1989-01-01

    We reviewed the nuclear medicine files of all patients enrolled in the sickle cell disease clinic who had had scans performed within the previous 5 years. We specifically looked for patterns of tracer uptake in these scans that would correlate with the severe anemia and consequent bone marrow hyperactivity of sickle cell patients. Thirty-three patients were included (21 men and 12 women) with a mean age of 26.8 years (range 17-48 years). The appearance of each of these patients' most recent scans was examined in the areas of the distal femurs, the proximal tibias and the distal tibias; a distinct triangular shaped pattern of increased activity was identified in these areas in a majority of patients. Thirty-three patients without sickle cell disease served as age-matched controls. This pattern was seen in 65.1% (95 out of 146 images) of the sickle cell patients' delayed images and 80.4% (82 out of 102 images) of their blood pool images. In contrast, the control patients demonstrated the triangular pattern in none of their blood pool studies (0%) and only 10.9% of their delayed bone images (P<0.001). The mean age of sickle cell patients with this pattern is 25.6 years which was significantly lower than that of those without this pattern (mean=37.5 years, P<0.05). Given the high prevalence of this unique scintigraphic pattern in a group of patients with known accelerated bone marrow function, these findings may be scintigraphic evidence of bone marrow expansion. The patient's age appears to be an important factor in visualization of this pattern. (orig.)

  6. Scintigraphic images of bacterial infection using aptamers directly labeled with {sup 99m}Tc

    Energy Technology Data Exchange (ETDEWEB)

    Santos, S.R.; Correa, C.R.; Andrade, A.S.R., E-mail: sararoberta7@hotmail.com, E-mail: crisrcorrea@gmail.com, E-mail: antero@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Barros, A.L.B.; Diniz, S.O.F.; Cardoso, V.N., E-mail: brancodebarros@yahoo.com.br, E-mail: valbertcardoso@yahoo.com.br, E-mail: simoneodilia@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Farmacia. Departamento de Analises Clinicas e Toxicologicas

    2015-07-01

    Staphylococcus aureus is specie of great medical importance and is the most commonly agent found in infections of soft tissues, bone infections and bone prostheses. In this study, aptamers selected to S. aureus were labeled by the direct method with {sup 99m}Tc and used for bacterial infection identification by scintigraphy. The radiolabeled aptamers radiochemical purity and stability were assessed by thin-layer chromatography (TLC). Three groups of Swiss mice (n=6) were used for the scintigraphic imaging studies. The first group was infected intramuscularly in the right thigh with S. aureus, the second group with C. albicans and the third group received zymosan to induce aseptic inflammation. After 24 h, radiolabeled aptamers (18 MBq) were injected by the tail vein. Scintigraphic images were acquired at 1 h and 4 h postinjection. The radiolabeling yield with {sup 99m}Tc was over 90%. The radiolabeled aptamers were stable in 0.9% saline, plasma and cysteine excess. The scintigraphic image profiles showed high uptake in the kidneys and bladder in all groups, indicating a main renal excretion consistent with the hydrophilic nature of the molecule. No accumulation of radioactivity was observed in the thyroid, stomach, liver and spleen, indicating acceptable levels of radiochemical impurities. The group infected with S. aureus showed a visible uptake in the infected right thigh at 1 h post-injection. For the control groups (C. albicans and zymosan) visible differences between the right and left thighs were not observed. The radiolabeled aptamers were able to distinguish aseptic inflammation from bacterial infection and bacterial from fungal infection. (author)

  7. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru [Chiba Univ. (Japan). School of Medicine

    1994-09-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author).

  8. Nontraumatic femoral head necrosis. Classification of bone scintigraphic findings and diagnostic value of SPECT following planar imaging

    International Nuclear Information System (INIS)

    Minoshima, Satoshi; Uchida, Yoshitaka; Anzai, Yoshimi; Uno, Kimiichi; Arimizu, Noboru

    1994-01-01

    This study was conducted to determine bone scintigraphic findings in nontraumatic femoral head avascular necrosis and diagnostic value of SPECT imaging following a conventional planar imaging. Forty-three femoral heads in twenty-six cases with idiopathic femoral head necrosis (n=2), systemic lupus erythematosus (n=22), aplastic anemia (n=1), and renal transplantation (n=1) were studied. The diagnosis for femoral head necrosis was based on magnetic resonance imaging as well as other diagnostic studies in all cases. Scintigraphic findings of planar and SPECT images were classified into six categories: normal (N); cold or decrease (C); partial increase with cold or decrease (PH+C); ring-like increase with a cold center (RH+C); partial increase (PH); diffuse and/or irregular increase (DH). Avascular necrosis was confirmed in twenty-four femoral heads, in which planar and SPECT images showed scintigraphic findings of N (n=3, 2), C (n=1, 3), PH+C (n=2, 8), RH+C (n=2, 3), PH (n=9, 2), and DH (n=7, 6), respectively. Femoral heads without avascular necrosis demonstrated planar and SPECT findings of N (n=16, 12), C (n=0, 6), and DH (n=3, 1), respectively. When considering C, PH+C, and RH+C as diagnostic findings for avascular necrosis, sensitivities of planar and SPECT images were 21% and 58%, and specificities were 100% and 68%, respectively. In nineteen femoral heads with normal planar findings (N), SPECT correctly identified avascular necrosis in two femoral heads and misidentified six normal femoral heads as avascular necrosis. In nineteen femoral heads with nondiagnostic abnormalities (PH, DH), SPECT correctly identified avascular necrosis in seven femoral heads and showed no false positive. Diagnostic planar findings in five femoral heads were concordant with SPECT diagnosis. These results indicate that SPECT imaging is most valuable when planar images show nondiagnostic abnormalities based on the proposed classification of scintigraphic findings. (author)

  9. Quantitative portable gamma spectroscopy sample analysis for non-standard sample geometries

    International Nuclear Information System (INIS)

    Enghauser, M.W.; Ebara, S.B.

    1997-01-01

    Utilizing a portable spectroscopy system, a quantitative method for analysis of samples containing a mixture of fission and activation products in nonstandard geometries was developed. The method can be used with various sample and shielding configurations where analysis on a laboratory based gamma spectroscopy system is impractical. The portable gamma spectroscopy method involves calibration of the detector and modeling of the sample and shielding to identify and quantify the radionuclides present in the sample. The method utilizes the intrinsic efficiency of the detector and the unattenuated gamma fluence rate at the detector surface per unit activity from the sample to calculate the nuclide activity and Minimum Detectable Activity (MDA). For a complex geometry, a computer code written for shielding applications (MICROSHIELD) is utilized to determine the unattenuated gamma fluence rate per unit activity at the detector surface. Lastly, the method is only applicable to nuclides which emit gamma rays and cannot be used for pure beta emitters. In addition, if sample self absorption and shielding is significant, the attenuation will result in high MDA's for nuclides which solely emit low energy gamma rays. The following presents the analysis technique and presents verification results demonstrating the accuracy of the method

  10. Analysis of portable gamma flaw detectors concerning radiation hygiene

    International Nuclear Information System (INIS)

    Makarova, T.V.

    1982-01-01

    Design and shields of gamma flaw detectors as one of the main factors responsible for personnel dose were studied. The analysis was conducted using the results of radiation hygienic surveys of gamma flaw detection laboratories functioning constantly in Estonia. It is shown that recently the replacement of GUP apparatuses by flaw detectors of RID and ''Gamma-RID'' (types which have design and shielding advantages is observed. However personnel doses have not reduced considerably for the last 10 years. This fact is attributed to design disadvantages of the RID and ''Gamma-RID'' apparatuses the removing of which will give the decreasing of annual personnel dose by 80 %

  11. The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)

    Energy Technology Data Exchange (ETDEWEB)

    Pinault, Jean-Louis [IAEA Expert, 96 rue du Port David, 45370 Dry (France)], E-mail: jeanlouis_pinault@hotmail.fr; Solis, Jose [Instituto Peruano de Energia Nuclear, Av. Canada No. 1470, San Borja, Lima 41 (Peru)

    2009-04-15

    The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories covering both borehole logging and on-line analysis on conveyor belt of raw materials.

  12. The use of fast digital filters for the processing of scintigraphic pictures

    International Nuclear Information System (INIS)

    Grochulski, W.; Penczek, P.

    1982-01-01

    A brief review of typical methods applied in the development of digital filters for the processing of scintigraphic pictures is given. A simple parametrisation of such filters in the frequency domain is proposed and successfully applied in the case of mathematically simulated IAEA phantoms. The FFT algorithm is used. A possible application of the fast Walsh transform is pointed out. (author)

  13. Computers in activation analysis and gamma-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, B. S.; D' Agostino, M. D.; Yule, H. P. [eds.

    1979-01-01

    Seventy-three papers are included under the following session headings: analytical and mathematical methods for data analysis; software systems for ..gamma..-ray and x-ray spectrometry; ..gamma..-ray spectra treatment, peak evaluation; least squares; IAEA intercomparison of methods for processing spectra; computer and calculator utilization in spectrometer systems; and applications in safeguards, fuel scanning, and environmental monitoring. Separate abstracts were prepared for 72 of those papers. (DLC)

  14. Prompt gamma-ray analysis of steel slag in concrete

    International Nuclear Information System (INIS)

    Naqvi, Akhtar Abbas; Garwan, Muhammad Ahmad; Nagadi, Mahmoud Mohammad; Rehman, Khateeb-ur; Raashid, Mohammad; Masalehuddin Mohiuddin, Mohammad; Al-Amoudi, Omar Saeed Baghabra

    2009-01-01

    Blast furnace slag (BFS) is added to Portland cement concrete to increase its durability, particularly its corrosion resistance. Monitoring the concentration of BFS in concrete for quality control purposes is desired. In this study, the concentration of BFS in concrete was measured by utilizing an accelerator-based prompt gamma-ray neutron activation analysis (PGNAA) setup. The optimum size of the BFS cement concrete specimen that produces the maximum intensity of gamma rays at the detector location was calculated through Monte Carlo simulations. The simulation results were experimentally validated through the gamma-ray yield measurement from BFS cement concrete specimens having different radii. The concentration of BFS in the cement concrete specimens was assessed through calcium and silicon gamma-ray yield measurement from cement concrete specimens containing 5 to 80 wt% BFS. The yield of calcium gamma rays decreases with increasing BFS concentration in concrete while the yield of silicon gamma rays increases with increasing BFS concentration in concrete. The calcium-to-silicon gamma-ray yield ratio has an inverse relation with BFS concentration in concrete. (author)

  15. Correlation between radiological, scintigraphic and histological changes in bone in rabbits following irradiation with single and fractionated doses

    International Nuclear Information System (INIS)

    Burgener, F.A.; King, M.A.; Weber, D.A.

    1979-01-01

    In the left hind legs of eight rabbits were irradiated with 1,750 rad in a single dose or with 4,650 rad divided over a period of three weeks. These animals, as well as four who had not been irradiated, were examined periodically radiologically and with 99 mTechnetium pyrophosphate scintigrams during one year. No difference could be detected between the results of the single and fractionated doses. Scintigraphically there was a biphasic increase in uptake, the first peak co-inciding with the irradiation and of vascular origin, whereas the second peak occured at four months and was due to a change in bone metabolism. At the end of a year uptake in the irradiated limb was slightly reduced. The earliest radiological changes were found after six months, at the end of the second scintigraphic peak; they consisted of coarsening and blurring of the trabeculae, non-homogeneous spotty mineralisation and endosteal scalloping. Six animals developed a radiation-induced bone sarcoma, first demonstrated either by scintigraphy or radiology depending on its histology. The value of combining radiological and scintigraphic examinations for the early detection of post-radiation abnormalities is stressed. (orig.) [de

  16. Scintigraphic determination of gastrointestinal transit times. A comparison with breath hydrogen and radiologic methods

    DEFF Research Database (Denmark)

    Madsen, J L; Larsen, N E; Hilsted, J

    1991-01-01

    A scintigraphic method for determination of gastrointestinal transit times was compared with the breath hydrogen test and a multiple-bolus, single-radiograph technique. A close temporal association was found between the caecal appearance of radioactivity and the onset of breath hydrogen excretion...... the breath hydrogen concentration profiles....

  17. Tables of nuclear constants for gamma activation analysis

    International Nuclear Information System (INIS)

    Randa, Z.; Kreisinger, F.

    1983-01-01

    Tables of nuclear data were compiled for the purpose of routine gamma (photon) activation analysis. The tables are arranged in two parts. The first one lists the radionuclides in the order of their atomic number. In the second one, the emitted gamma-ray photons are tabulated in the order of increasing energy. Tables contain the gamma emitters produced by the following photonuclear reactions: (#betta#,#betta#), (#betta#,n), (#betta#,p), (#betta#,p+n), (#betta#,2n), (#betta#,3n), (#betta#,4n), (#betta#,2p), (#betta#,α), (#betta#,α+n), (#betta#,α+p). This set corresponds to the maximum energy of the bremsstrahlung of roughly 45 MeV. The program for the output of the tabulated data allows the data as required for specific irradiation and measuring reduction of conditions (reaction thresholds, energy and intensity of gamma-rays, half-lives and target elements). (author)

  18. MO-FG-202-06: Improving the Performance of Gamma Analysis QA with Radiomics- Based Image Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wootton, L; Nyflot, M; Ford, E [University of Washington Department of Radiation Oncology, Seattle, WA (United States); Chaovalitwongse, A [University of Washington Department of Industrial and Systems Engineering, Seattle, Washington (United States); University of Washington Department of Radiology, Seattle, WA (United States); Li, N [University of Washington Department of Industrial and Systems Engineering, Seattle, Washington (United States)

    2016-06-15

    Purpose: The use of gamma analysis for IMRT quality assurance has well-known limitations. Traditionally, a simple thresholding technique is used to evaluated passing criteria. However, like any image the gamma distribution is rich in information which thresholding mostly discards. We therefore propose a novel method of analyzing gamma images that uses quantitative image features borrowed from radiomics, with the goal of improving error detection. Methods: 368 gamma images were generated from 184 clinical IMRT beams. For each beam the dose to a phantom was measured with EPID dosimetry and compared to the TPS dose calculated with and without normally distributed (2mm sigma) errors in MLC positions. The magnitude of 17 intensity histogram and size-zone radiomic features were derived from each image. The features that differed most significantly between image sets were determined with ROC analysis. A linear machine-learning model was trained on these features to classify images as with or without errors on 180 gamma images.The model was then applied to an independent validation set of 188 additional gamma distributions, half with and half without errors. Results: The most significant features for detecting errors were histogram kurtosis (p=0.007) and three size-zone metrics (p<1e-6 for each). The sizezone metrics detected clusters of high gamma-value pixels under mispositioned MLCs. The model applied to the validation set had an AUC of 0.8, compared to 0.56 for traditional gamma analysis with the decision threshold restricted to 98% or less. Conclusion: A radiomics-based image analysis method was developed that is more effective in detecting error than traditional gamma analysis. Though the pilot study here considers only MLC position errors, radiomics-based methods for other error types are being developed, which may provide better error detection and useful information on the source of detected errors. This work was partially supported by a grant from the Agency for

  19. Scintigraphic diagnosis of stress-induced incomplete fractures of the proximal tibia

    International Nuclear Information System (INIS)

    Collier, B.D.; Johnson, R.P.; Carrera, G.F.; Akhtar, K.; Isitman, A.T.

    1984-01-01

    Incomplete stress fractures of the proximal tibial diaphysis can be diagnosed by bone scintigraphy. The scintigraphic appearance of incomplete rather than complete tibial stress fractures is apparently reported for the first time in this article. With no treatment other than restricted activity, this injury heals rapidly and completely in 4 to 6 weeks. The major threat to the patient's welfare is unfounded suspicion of tumor or infection which may lead to biopsy or inappropriate therapy

  20. Comparison of gamma knife validation film's analysis results of different film dose analysis software

    International Nuclear Information System (INIS)

    Cheng Xiaojun; Zhang Conghua; Liu Han; Dai Fuyou; Hu Chuanpeng; Liu Cheng; Yao Zhongfu

    2011-01-01

    Objective: To compare the analytical result of different kinds of film dose analysis software for the same gamma knife, analyze the reasons of difference caused, and explore the measurements and means for quality control and quality assurance during testing gamma knife and analyzing its result. Methods: To test the Moon Deity gamma knife with Kodak EDR2 film and γ-Star gamma knife with GAFCHROMIC® EBT film, respectively. All the validation films are scanned to proper imagine format for dose analysis software by EPSON PERFECTION V750 PRO scanner. Then imagines of Moon Deity gamma knife are analyzed with Robot Knife Adjuvant 1.09 and Fas-09 1.0, and imagines of γ-Star gamma knife with Fas-09 and MATLAB 7.0. Results: There is no significant difference in the maximum deviation of radiation field size (Full Width at Half Maximum, FWHM) and its nominal value between Robot Knife Adjuvant and Fas-09 for Moon Deity gamma knife (t=-2.133, P>0.05). The analysis on the radiation field's penumbra region width of collimators which have different sizes indicated that the differences are significant (t=-8.154, P<0.05). There is no significant difference in the maximum deviation of FWHM and its nominal value between Fas-09 and MATLAB for γ-Star gamma knife (t=-1.384, P>0.05). However, following national standards,analysis of φ4 mm width of collimators can obtain different results according to the two kinds software, and the result of Fas-09 is not qualified while MATLAB is qualified. The analysis on the radiation field's penumbra region width of collimators which have different sizes indicates that the differences are significant (t=3.074, P<0.05). The imagines are processed with Fas-09. The analysis of imagine in the pre-and the post-processing indicates that there is no significant difference in the maximum deviation of FWHM and its nominal value (t=0.647, P>0.05), and the analytical result of the radiation field's penumbra region width indicates that there is

  1. Assessment of skeleton scintigraphic study in breast cancer patients (relative to 322 observations)

    International Nuclear Information System (INIS)

    Liechtmaneger, Nicole.

    1976-01-01

    The results of scintigraphic whole-skeleton examinations have recently been improved by the use of sup(99m)Tc labelled phosphorus compounds. An assessment was made of 368 explorations, most of which were carried out with pyrophosphates and a few, the most recent, with ethane hydroxy diphosphonate, both labelled with sup(99m)Tc. For pyrophosphates a 10 mCi intraveinous injection is followed by a latency time of about 3 hours before the scintigraphic examination. In the case of diphosphonates, which have only been used lately and on relatively few cases, the same 10 mCi intravenous injection is administered but the latency time before the examination is only half as long, i.e. about 1h30 min, which is a definite advantage. However the number of examinations carried out with the latter is too small to afford a significant comparison between the two products. The main object of this work is to count the hyperfixation centres and to estimate their specificity and their coexistence or otherwise with clinical or radiological signs [fr

  2. Gamma scintigraphy in the evaluation of pharmaceutical dosage forms

    International Nuclear Information System (INIS)

    Davis, S.S.; Hardy, J.G.; Newman, S.P.; Wilding, I.R.

    1992-01-01

    Gamma-scintigraphy is applied extensively in the development and evaluation of pharmaceutical drug delivery systems. It is used particularly for monitoring formulations in the gastrointestinal and respiratory tracts. The radiolabelling is generally achieved by the incorporation of an appropriate technetium-99m or indium-111 labelled radiopharmaceutical into the formulation. In the case of complex dosage forms, such as enteric-coated tablets, labelling is best undertaken by the addition of a non-radioactive tracer such as samarium-152 or erbium-170 followed by neutron activation of the final product. Systems investigated include tablets and multiparticulates for oral administration, enemas and suppositories, metered dose inhalers and nebulisers, and nasal sprays and drops. Gamma-scintigraphy provides information on the deposition, dispersion and movement of the formulation. The combination of such studies with the assay of drug levels in blood or urine specimens, pharmacoscintigraphy, provides information concerning the sites of drug release and absorption. Data acquired from the scintigraphic evaluation of pharmaceutical dosage forms are now being used increasingly at all stages of product development, from the assessment of prototype delivery systems to supporting the product licence application. (orig.)

  3. Gamma scintigraphy in the evaluation of pharmaceutical dosage forms

    Energy Technology Data Exchange (ETDEWEB)

    Davis, S.S.; Hardy, J.G.; Newman, S.P.; Wilding, I.R. (Pharmaceutical Profiles Ltd., Nottingham (United Kingdom))

    1992-11-01

    Gamma-scintigraphy is applied extensively in the development and evaluation of pharmaceutical drug delivery systems. It is used particularly for monitoring formulations in the gastrointestinal and respiratory tracts. The radiolabelling is generally achieved by the incorporation of an appropriate technetium-99m or indium-111 labelled radiopharmaceutical into the formulation. In the case of complex dosage forms, such as enteric-coated tablets, labelling is best undertaken by the addition of a non-radioactive tracer such as samarium-152 or erbium-170 followed by neutron activation of the final product. Systems investigated include tablets and multiparticulates for oral administration, enemas and suppositories, metered dose inhalers and nebulisers, and nasal sprays and drops. Gamma-scintigraphy provides information on the deposition, dispersion and movement of the formulation. The combination of such studies with the assay of drug levels in blood or urine specimens, pharmacoscintigraphy, provides information concerning the sites of drug release and absorption. Data acquired from the scintigraphic evaluation of pharmaceutical dosage forms are now being used increasingly at all stages of product development, from the assessment of prototype delivery systems to supporting the product licence application. (orig.).

  4. Interferences in Prompt {gamma} Analysis of corrosive contaminants in concrete

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, KFUPM Box 1815, Dhahran-31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2006-12-21

    An accelerator-based Prompt Gamma Neutron Activation Analysis (PGNAA) setup has been developed to measure the concentration of corrosive chloride and sulfate contaminants in concrete. The Minimum Detectable Concentration (MDC) limit of chlorine and sulfur in the concrete depends upon the {gamma}-ray used for elemental analysis. For more interfering {gamma}-rays, the MDC limit is higher than that for less interfering {gamma}-rays. The MDC limit of sulfur in concrete measured for the KFUPM PGNAA setup was calculated to be 0.60{+-}0.19 wt%. The MDC limit is equal to the upper limit of sulfur concentration in concrete set by the British Standards. The MDC limit of chlorine in concrete for the KFUPM PGNAA setup, which was calculated for less interfering 1.165 MeV {gamma}-rays, was found to be 0.075{+-}0.025 wt%. The lower limits of the MDC of chlorine in concrete was 73% higher than the limit set by American Concrete Institute. The limit of the MDC can be improved to the desired standard by increasing the intensity of neutron source. For moreinterfering 5.715 and 6.110 MeV chlorine {gamma}-rays the MDC limit was found to be 2-3 times larger than that of 1.165 MeV {gamma}-rays. When normalized to the same intensity of the neutron source, the MDC limits of chlorine and sulfur in concrete from the KFUPM PGNAA setup are better than MDC limits of chlorine in concrete obtained with the {sup 241}Am-Be source-based PGNAA setup. This study has shown that an accelerator-based PGNAA setup can be used in chlorine and sulfur analysis of concrete samples.

  5. The Dynamic Characteristic Analysis of Mini Gamma Calorimeter

    International Nuclear Information System (INIS)

    Setiyanto

    2004-01-01

    The gamma calorimeter is a facility to measure the gamma heating in the nuclear reactor. The dimensions of the conventional calorimeters are in general too large, that is an inconvenience if those calorimeters will be applied in the high temperature reactor as a nuclear power plant. To avoid that inconvenience, it is necessary to propose the innovation on the feature of the existing calorimeter. The basic idea of the innovation is to create the small type of calorimeter without the absorbed material. The last analysis was realized to determine of the static calorimeter characteristic or sensitivities as a function of the dimension and the material of gas isolations. Based on those results, the analyses is reasonably to be continued to determine the dynamic characteristic or period of calorimeter. The analysis was performed using the finite difference method, two dimension simplified. It can be concluded that the mini gamma calorimeter proposed is reasonable to be made. (author)

  6. Differential diagnosis of scintigraphic brain centres by 75Se selenite

    International Nuclear Information System (INIS)

    Bestagno, M.; Garraffa, V.; Rembado, R.; Guerra, U.

    1975-01-01

    Since standard brain scintigraphy with sup(99m)Tc is not always adequate for a satisfactory differential diagnosis of the radioactive foci detected, the possibilities of 75 Se sodium selenite were investigated. It was observed that in centres due to a vascular lesion the selenite concentration is always low, rising steeply in neoplasmic foci. The 75 Se-selenite scintigraphic method is considered highly valid, complementing that of sup(99m)Tc when this latter is unsuitable for diagnosis of the nature of cerebral foci [fr

  7. Interest of scintigraphic imaging in Madagascar for the diagnosis of ectopic parathyroid adenoma, about one case

    International Nuclear Information System (INIS)

    Andriantsoa, J.; Andriamanalina, T.; Ramamonjy, A.; Ranivontsoarivony, M.; Ramahandridona, G.; Razafindramboa, H.; Gizy Ratiambahoaka, D.

    2008-01-01

    This study reports the first case of ectopic parathyroid adenoma, diagnosed in the Department of Nuclear Medicine in Antananarivo. This clinical vignette illustrates the interest of the MIBI-Tc-99 m scan in locating this adenoma and its diagnostic confirmation after six years of erratic diagnosis. A whole body bone scintigraphy has also allowed to assess the state of bone metabolism and study outbreaks of fracture. The parathyroid scintigraphy was carried out after intra-venous administration of 666 MBq of MIBI- 99m Tc. Dynamic images, static early and late static were acquired with a gamma camera E-Cam Siemens. The whole body bone scan was carried out after administration of 555 MBq of M.D.P.-Tc-99 m. The results evidenced the presence of an para-aortic increased uptake area pointing to a left parathyroid adenoma. The persistence of a late left sub maxillary increased uptake area raises, however, a reservation about the existence of a second adenoma. The bone scan displayed global skeletal remodeling, non suggestive of metastases, as it was mentioned with the CT-scan. In a diagnostic tools limited environment, skeletal pain refractory to pain-killers, a chronic hypercalcemia associated with an increased parathyroid hormone level, should trigger the scintigraphic exploration in order to avoid bone and renal complications

  8. Retrospective analysis of 'gamma distribution' based IMRT QA criteria

    International Nuclear Information System (INIS)

    Wen, C.; Chappell, R.A.

    2010-01-01

    Full text: IMRT has been implemented into clinical practice at Royal Hobart Hospital (RHH) since mid 2006 for treating patients with Head and Neck (H and N) or prostate tumours. A local quality assurance (QA) acceptance criteria based on 'gamma distribution' for approving IMRT plan was developed and implemented in early 2007. A retrospective analysis of such criteria over 194 clinical cases will be presented. The RHH IMRT criteria was established with assumption that gamma distribution obtained through inter-comparison of 2 D dose maps between planned and delivered was governed by a positive-hail' normal distribution. A commercial system-MapCheck was used for 2 D dose map comparison with a built-in gamma analysis tool. Gamma distribution histogram was generated and recorded for all cases. By retrospectively analysing those distributions using curve fitting technique, a statistical gamma distribution can be obtained and evaluated. This analytical result can be used for future IMRT planing and treatment delivery. The analyses indicate that gamma distribution obtained through MapCheckTM is well under the normal distribution, particularly for prostate cases. The applied pass/fail criteria is not overly sensitive to identify 'false fails' but can be further tighten-up for smaller field while for larger field found in both H and N and prostate cases, the criteria was correctly applied. Non-uniform distribution of detectors in MapCheck and experience level of planners are two major factors to variation in gamma distribution among clinical cases. This criteria derived from clinical statistics is superior and more accurate than single-valued criteria for lMRT QA acceptance procedure. (author)

  9. TPASS: a gamma-ray spectrum analysis and isotope identification computer code

    International Nuclear Information System (INIS)

    Dickens, J.K.

    1981-03-01

    The gamma-ray spectral data-reduction and analysis computer code TPASS is described. This computer code is used to analyze complex Ge(Li) gamma-ray spectra to obtain peak areas corrected for detector efficiencies, from which are determined gamma-ray yields. These yields are compared with an isotope gamma-ray data file to determine the contributions to the observed spectrum from decay of specific radionuclides. A complete FORTRAN listing of the code and a complex test case are given

  10. Scintigraphic calf perfusion symmetry after exercise and prediction of cardiovascular events: One stone to kill two birds?

    International Nuclear Information System (INIS)

    Tellier, Philippe; Lecouffe, Pascal; Zureik, Mahmoud

    2007-01-01

    Background: Peripheral arterial disease (PAD) is commonly associated with a high cardiovascular mortality and morbidity as a marker of plurifocal atherosclerosis. Whether exercise thallium perfusion muscular asymmetry in the legs associated with PAD has prognostic value is unknown. Such a hypothesis was evaluated in a prospective study which remains the gold standard in clinical research. Methods and results: Scintigraphic calf perfusion symmetry after exercise (SCPSE) was measured at the end of a maximal or symptom-limited treadmill exercise test in 358 patients with known or suspected coronary artery disease (CAD). During the follow-up period (mean 85.3±32.8 months), 93 cardiovascular events and deaths (incident cases) occurred. Among those incident cases, the percentage of subjects with higher SCPSE values (third tertile) was 45.2%, versus 29.1% in controls (lower tertiles) (p=0.005). In stepwise multivariate analysis performed with the Cox proportional hazards model, previous CAD and SCPSE were the only significant independent predictors of prognosis. The multivariate relative risk of cardiovascular death or event in subjects with higher values of SCPSE was 1.94 (95% CI: 1.15-3.21; p<0.01). Conclusions: Scintigraphic calf perfusion asymmetry after exercise was independently associated with incident cardiovascular events in high-risk subjects. This index, which is easily and quickly calculated, could be used for evaluation of cardiovascular risk

  11. Scintigraphic calf perfusion symmetry after exercise and prediction of cardiovascular events: One stone to kill two birds?

    Science.gov (United States)

    Tellier, Philippe; Lecouffe, Pascal; Zureik, Mahmoud

    2007-02-01

    BackgroundPeripheral arterial disease (PAD) is commonly associated with a high cardiovascular mortality and morbidity as a marker of plurifocal atherosclerosis. Whether exercise thallium perfusion muscular asymmetry in the legs associated with PAD has prognostic value is unknown. Such a hypothesis was evaluated in a prospective study which remains the gold standard in clinical research. Methods and resultsScintigraphic calf perfusion symmetry after exercise (SCPSE) was measured at the end of a maximal or symptom-limited treadmill exercise test in 358 patients with known or suspected coronary artery disease (CAD). During the follow-up period (mean 85.3±32.8 months), 93 cardiovascular events and deaths (incident cases) occurred. Among those incident cases, the percentage of subjects with higher SCPSE values (third tertile) was 45.2%, versus 29.1% in controls (lower tertiles) ( p=0.005). In stepwise multivariate analysis performed with the Cox proportional hazards model, previous CAD and SCPSE were the only significant independent predictors of prognosis. The multivariate relative risk of cardiovascular death or event in subjects with higher values of SCPSE was 1.94 (95% CI: 1.15-3.21; p<0.01). ConclusionsScintigraphic calf perfusion asymmetry after exercise was independently associated with incident cardiovascular events in high-risk subjects. This index, which is easily and quickly calculated, could be used for evaluation of cardiovascular risk.

  12. Imaging of heterogeneous materials by prompt gamma-ray neutron activation analysis

    International Nuclear Information System (INIS)

    Staples, P.; Prettyman, T.; Lestone, J.

    1998-01-01

    The authors have used a tomographic gamma scanner (TGS) to produce tomographic prompt gamma-ray neutron activation analysis imaging (PGNAA) of heterogeneous matrices. The TGS was modified by the addition of graphite reflectors that contain isotopic neutron sources for sample interrogation. The authors are in the process of developing the analysis methodology necessary for a quantitative assay of large containers of heterogeneous material. This nondestructive analysis (NDA) technique can be used for material characterization and the determination of neutron assay correction factors. The most difficult question to be answered is the determination of the source-to-sample coupling term. To assist in the determination of the coupling term, the authors have obtained images for a range of sample that are very well characterized, such as, homogenous pseudo one-dimensional samples to three-dimensional heterogeneous samples. They then compare the measurements to MCNP calculations. For an accurate quantitative measurement, it is also necessary to determine the sample gamma-ray self attenuation at higher gamma-ray energies, namely pair production should be incorporated into the analysis codes

  13. The scintigraphic investigation of sacroiliac disease.

    Science.gov (United States)

    Lentle, B C; Russell, A S; Percy, J S; Jackson, F I

    1977-06-01

    Bone scintigraphs obtained with both Technetium-99m polyphosphate and Technetium-99m pyrophosphate have been abnormal at the sacroiliac joints of 44 patients with definite ankylosing spondylitis (AS). Because of the normal registration of the sacroiliac joints on bone scintigraphy, it has been necessary to develop a profile-scan technique to quantify the abnormality that proves to be significantly different from the normal finding. In 17 patients with a strong clinical suspicion of AS but normal radiographs, the sacroiliac joints have frequently been abnormal. This finding is meaningful because there is a common occurence in this group of the histocompatibility antigen HL A-B27, known to be a marker of AS. We also note the frequency of abnormal sacroiliac scinitigrams in 26 patients with rheumatoid arthritis and in a group of other diseases-Crohn's disease, uveitis, psoriasis, ulcerative colitis, and Reiter's disease-all of which share some of the manifestations of AS.

  14. Scintigraphic scoring system for grading severity of gastro-esophageal reflux on 99mTc sulfur colloid gastro-esophageal reflux scintigraphy: A prospective study of 39 cases with pre and post treatment assessment.

    Science.gov (United States)

    Puranik, Ameya D; Nair, Gopinathan; Aggarwal, Rajiv; Bandyopadhyay, Abhijit; Shinto, Ajit; Zade, Anand

    2013-04-01

    The study aimed at developing a scoring system for scintigraphic grading of gastro-esophageal reflux (GER), on gastro-esophageal reflux scintigraphy (GERS) and comparison of clinical and scintigraphic scores, pre- and post-treatment. A total of 39 cases with clinically symptomatic GER underwent 99mTc sulfur colloid GERS; scores were assigned based on the clinical and scintigraphic parameters. Post domperidone GERS was performed after completion of treatment. Follow up GERS was performed and clinical and scintigraphic parameters were compared with baseline parameters. Paired t-test on pre and post domperidone treatment clinical scores showed that the decline in post-treatment scores was highly significant, with P value reflux and also for following children post-treatment.

  15. Stress fractures of the humerus, radius, and tibia in horses: clinical features and radiographic and/or scintigraphic appearance

    International Nuclear Information System (INIS)

    Mackey, V.S.; Trout, D.R.; Meagher, D.M.; Hornof, W.J.

    1987-01-01

    The medical records, radiographic and nuclear scintigraphic findings of 26 racing horses with 27 stress fracture episodes of the humerus, radius, or tibia were reviewed. The purposes of this study were to describe the radiographic and/or scintigraphic features of stress fractures of the humerus, radius, or tibia, and to evaluate the signalment and history of horses in which stress fracture occurred. Stress fractures of the three long bones examined were primarily seen in 2- and 3-year-old male Thoroughbred horses; commonly, the onset of lameness was immediately following training gallops or racing. There were 13 humeral stress fracture episodes in 12 horses. Ten were in the proximal caudolateral cortex, and three were in the distal craniomedial cortex. Radical stress fractures were seen in three horses, all in the midshaft radius. Tibial stress fractures were diagnosed in 11 horses. They were located in the proximal lateral tibia in six horses, the distal caudolateral tibia in three horses, and the midshaft tibia in three horses. Fifteen stress fractures were diagnosed with radiography alone, one was diagnosed with scintigraphy alone, nine were diagnosed with radiographs and scintigraphy, and, in two horses, radiographs were negative, but the scintigraphic findings were consistent with stress fracture

  16. Gamma self-shielding correction factors calculation for aqueous bulk sample analysis by PGNAA technique

    International Nuclear Information System (INIS)

    Nasrabadi, M.N.; Mohammadi, A.; Jalali, M.

    2009-01-01

    In this paper bulk sample prompt gamma neutron activation analysis (BSPGNAA) was applied to aqueous sample analysis using a relative method. For elemental analysis of an unknown bulk sample, gamma self-shielding coefficient was required. Gamma self-shielding coefficient of unknown samples was estimated by an experimental method and also by MCNP code calculation. The proposed methodology can be used for the determination of the elemental concentration of unknown aqueous samples by BSPGNAA where knowledge of the gamma self-shielding within the sample volume is required.

  17. Evaluation of peak-fitting software for gamma spectrum analysis

    International Nuclear Information System (INIS)

    Zahn, Guilherme S.; Genezini, Frederico A.; Moralles, Mauricio

    2009-01-01

    In all applications of gamma-ray spectroscopy, one of the most important and delicate parts of the data analysis is the fitting of the gamma-ray spectra, where information as the number of counts, the position of the centroid and the width, for instance, are associated with each peak of each spectrum. There's a huge choice of computer programs that perform this type of analysis, and the most commonly used in routine work are the ones that automatically locate and fit the peaks; this fit can be made in several different ways - the most common ways are to fit a Gaussian function to each peak or simply to integrate the area under the peak, but some software go far beyond and include several small corrections to the simple Gaussian peak function, in order to compensate for secondary effects. In this work several gamma-ray spectroscopy software are compared in the task of finding and fitting the gamma-ray peaks in spectra taken with standard sources of 137 Cs, 60 Co, 133 Ba and 152 Eu. The results show that all of the automatic software can be properly used in the task of finding and fitting peaks, with the exception of GammaVision; also, it was possible to verify that the automatic peak-fitting software did perform as well as - and sometimes even better than - a manual peak-fitting software. (author)

  18. Radioimmunological determination of alphafetoprotein and gamma camera scintigraphy in patients with tumours of the testes

    International Nuclear Information System (INIS)

    Milkov, V.; Sultanov, S.

    1989-01-01

    By means of radioimmunological method the blood serum concentrations of alphafetoprotein (AFP) were investigated in 35 patients with histologically confirmed tumours of the testes prior to surgical intervention. Parallely in all patients gamma camera scintigraphy of the testes was performed. Seven of all investigated 15 patients with seminoma of the testes had increased concentrations of AFP in the blood serum. In 7 of the examinated 10 patients with diagnosis teratoma of the testes increased blood serum concentrations of AFP were established, while 6 of the examined patients with embryonic tumour of the testis had increased blood serum concentrations of AFP. In comparison with the results established in the control group of 30 healthy males, this increase of AFP was statistically reliable. All examined patients showed positive scintigraphic findings, which confirmed the diagnosis of tumour of the testes. It is concluded that the parallel determination of blood serum AFP and gamma camera investigation of the testes could be successfully apllied in the diagnosis of these malignant diseases

  19. Gastric emptying and intragastric distribution of lipids in man. A new scintigraphic method of study

    International Nuclear Information System (INIS)

    Jian, R.; Vigneron, N.; Najean, Y.; Bernier, J.J.

    1982-01-01

    We measured gastric emptying of fat and water from a solid-liquid meal in healthy volunteers using a tubeless scintigraphic method. 75 Se glycerol triether, incorporated in butter, was the lipid-phase marker, and /sup 99m/Tcm, ingested with 250 ml water, the non-lipid phase marker. In seven of these subjects we also measured the gastric emptying of solids and liquids with /sup 99m/Tc bound to cooked egg whites as the solid-phase marker and 111 In ingested with 250 ml water as the marker of the solid and aqueous phases. Emptying and intragastric repartition of each marker were measured by detection of radioactivity changes over the abdominal area using a gamma-camera. The stability and the specificity of the labeling was checked for each marker. Mean gastric emptying rate (expressed as percentage ingested marker emptied per hr) of lipids (17.4 +/- 2.4) was much lower than that of the rest of the meal (34.2 +/- 1.8) and slightly, but significantly, lower than that of solids (22.8 +/- 1.8). An intragastric layering of fat above nonlipids was observed only after the first postprandial hour and remained moderate. Thus, lipids are emptied more slowly than any other component of an ordinary meal, and this is not due only to layering of fat above water

  20. Gastric emptying and intragastric distribution of lipids in man. A new scintigraphic method of study

    Energy Technology Data Exchange (ETDEWEB)

    Jian, R.; Vigneron, N.; Najean, Y.; Bernier, J.J.

    1982-08-01

    We measured gastric emptying of fat and water from a solid-liquid meal in healthy volunteers using a tubeless scintigraphic method. /sup 75/Se glycerol triether, incorporated in butter, was the lipid-phase marker, and /sup 99m/Tcm, ingested with 250 ml water, the non-lipid phase marker. In seven of these subjects we also measured the gastric emptying of solids and liquids with /sup 99m/Tc bound to cooked egg whites as the solid-phase marker and /sup 111/In ingested with 250 ml water as the marker of the solid and aqueous phases. Emptying and intragastric repartition of each marker were measured by detection of radioactivity changes over the abdominal area using a gamma-camera. The stability and the specificity of the labeling was checked for each marker. Mean gastric emptying rate (expressed as percentage ingested marker emptied per hr) of lipids (17.4 +/- 2.4) was much lower than that of the rest of the meal (34.2 +/- 1.8) and slightly, but significantly, lower than that of solids (22.8 +/- 1.8). An intragastric layering of fat above nonlipids was observed only after the first postprandial hour and remained moderate. Thus, lipids are emptied more slowly than any other component of an ordinary meal, and this is not due only to layering of fat above water.

  1. A methodology for radiological accidents analysis in industrial gamma radiography

    International Nuclear Information System (INIS)

    Silva, F.C.A. da.

    1990-01-01

    A critical review of 34 published severe radiological accidents in industrial gamma radiography, that happened in 15 countries, from 1960 to 1988, was performed. The most frequent causes, consequences and dose estimation methods were analysed, aiming to stablish better procedures of radiation safety and accidents analysis. The objective of this work is to elaborate a radiological accidents analysis methodology in industrial gamma radiography. The suggested methodology will enable professionals to determine the true causes of the event and to estimate the dose with a good certainty. The technical analytical tree, recommended by International Atomic Energy Agency to perform radiation protection and nuclear safety programs, was adopted in the elaboration of the suggested methodology. The viability of the use of the Electron Gamma Shower 4 Computer Code System to calculate the absorbed dose in radiological accidents in industrial gamma radiography, mainly at sup(192)Ir radioactive source handling situations was also studied. (author)

  2. Prompt gamma analysis of chlorine in concrete for corrosion study

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2006-02-15

    Measurement of chlorine in concrete is very important for studying of corrosion of reinforcing steel in concrete. Corrosion of reinforcing steel is primarily ascribed to the penetration of chloride ions to the steel surface. Preventive measures for avoiding concrete structure reinforcement corrosion requires monitoring the chloride ion concentration in concrete so that its concentration does not exceed a threshold limit to initiate reinforcement concrete corrosion. An accelerator based prompt gamma neutron activation analysis (PGNAA) setup has been developed for non-destructive analysis of elemental composition of concrete samples. The setup has been used to measure chlorine concentration in concrete samples over a 1-3 wt% concentration range. Although a strong interference has been observed between the chlorine {gamma}-rays and calcium {gamma}-rays from concrete, the chlorine concentration in concrete samples has been successfully measured using the 1.164 and 7.643 MeV chlorine {gamma}-rays. The experimental data were compared with the results of the Monte Carlo simulations. An excellent agreement has been achieved between the experimental data and results of Monte Carlo simulations. The study has demonstrated the successful use of the accelerator-based PGNAA setup in non-destructive analysis of chlorine in concrete samples.

  3. 123I-BMIPP delayed scintigraphic imaging in patients with chronic heart failure

    International Nuclear Information System (INIS)

    Kida, Keisuke; Akashi, Yoshihiro J.; Yoneyama, Kihei; Shimokawa, Mitsuhiro; Musha, Haruki

    2008-01-01

    The objective of the present study was to clarify the ability of 123 I-beta-methyl-iodophenylpentadecanoic acid ( 123 I-BMIPP) to evaluate the heart-to-mediastinum (H/M) ratio and myocardial global washout rate (WR) in patients with chronic heart failure (CHF). The severity of CHF was evaluated on the basis of the New York Heart Association (NYHA) classification. Twenty patients with CHF (13 with idiopathic dilated cardiomyopathy and 7 with ischemic cardiomyopathy) and 11 age-matched controls underwent myocardial radionuclide imaging. Scintigraphic images were obtained from each participant at the early (30 min following radio-isotope injection) and late (4 h) phases using 123 I-BMIPP. The H/M ratio and WR were calculated from planar images. Concentrations of plasma brain natriuretic peptide (BNP) were measured prior to the scintigraphic study. The 123 I-BMIPP uptake of early H/M and global WR did not significantly differ among groups, but uptake of delayed H/M was significantly lower in patients with NYHA class III than in controls (control 2.47±0.39; class III 1.78±0.28 P 123 I-BMIPP uptake of delayed H/M enhances the image of CHF severity. The myocardial WR of 123 I-BMIPP also effectively depicted the severity of CHF. (author)

  4. Simultaneous analysis of qualitative parameters of solid fuel using complex neutron gamma method

    International Nuclear Information System (INIS)

    Dombrovskij, V.P.; Ajtsev, N.I.; Ryashchikov, V.I.; Frolov, V.K.

    1983-01-01

    A study was made on complex neutron gamma method for simultaneous analysis of carbon content, ash content and humidity of solid fuel according to gamma radiation of inelastic fast neutron scattering and radiation capture of thermal neutrons. Metrological characteristics of pulse and stationary neutron gamma methods for determination of qualitative solid fuel parameters were analyzed, taking coke breeze as an example. Optimal energy ranges of gamma radiation detection (2-8 MeV) were determined. The advantages of using pulse neutron generator for complex analysis of qualitative parameters of solid fuel in large masses were shown

  5. Scintigraphic detection of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging

    Energy Technology Data Exchange (ETDEWEB)

    Georgiou, E C; Arkas, A Z; Alevizaki, C C; Gnafakis, N [Evangelismos Hospital, Athens (Greece). Dept. of Endocrinology and Radioisotopes; Evangelismos Hospital, Athens (Greece). Gynaecology Clinic)

    1979-12-01

    Three cases of scintigraphic visualization of gynaecological tumours by sup(99m)Tc-HSA blood pool imaging are presented, i.e. one case of fibrothecoma ('cold' area visualization) and two cases of fibromyoma ('hot' area visualization). It is suggested that this technique may be useful in the preoperative evaluation of gynaecological tumours and their vascularity.

  6. Scintigraphic assessment of ectopic splenic tissue localization and function following splenectomy for trauma

    Energy Technology Data Exchange (ETDEWEB)

    Zwas, S.T.; Samra, D.; Samra, Y.; Sibber, G.R.

    1986-07-01

    Twenty-three subjects who had a splenectomy as a result of trauma underwent scintigraphic evaluation with a sensitive heat-denatured sup(99m)Tc-labeled red blood cells (DRBC). This method enabled detection of ectopic splenic tissue foci (ESTF) as small as 1x1 cm in diameter. ESTF splenosis or accessory spleen was detected in 15 cases (65%), a higher incidence than previously reported. The size of the ESTF ranged from 1x1 to 5x10 cm (0.8-40 cm/sup 2/), and 53% were less than 2x2 cma (3 cm/sup 2/). A new multiparametric scintigraphic evaluating technique is described, which estimates the quantity of ESTF and its grade of activity, relative to that of the liver. The technique is a highly efficient assessor of ESTF function. Good correlation was found between the size and activity of the ESTF and the presence of Howell-Jolly bodies (HJB), but with a low sensitivity for detecting small ESTF. Correlation was low between residual splenic tissue and concentrations of IgM, IgA and IgG immunoglobulins. The sup(99m)Tc-DRBC method described is recommended for verification of ESTF existence, localization, and function.

  7. Scintigraphic assessment of ectopic splenic tissue localization and function following splenectomy for trauma

    International Nuclear Information System (INIS)

    Zwas, S.T.

    1986-01-01

    Twenty-three subjects who had a splenectomy as a result of trauma underwent scintigraphic evaluation with a sensitive heat-denatured sup(99m)Tc-labeled red blood cells (DRBC). This method enabled detection of ectopic splenic tissue foci (ESTF) as small as 1x1 cm in diameter. ESTF splenosis or accessory spleen was detected in 15 cases (65%), a higher incidence than previously reported. The size of the ESTF ranged from 1x1 to 5x10 cm (0.8-40 cm 2 ), and 53% were less than 2x2 cma (3 cm 2 ). A new multiparametric scintigraphic evaluating technique is described, which estimates the quantity of ESTF and its grade of activity, relative to that of the liver. The technique is a highly efficient assessor of ESTF function. Good correlation was found between the size and activity of the ESTF and the presence of Howell-Jolly bodies (HJB), but with a low sensitivity for detecting small ESTF. Correlation was low between residual splenic tissue and concentrations of IgM, IgA and IgG immunoglobulins. The sup(99m)Tc-DRBC method described is recommended for verification of ESTF existence, localization, and function. (orig.)

  8. Scintigraphic pattern of small bowel bleeding

    International Nuclear Information System (INIS)

    Anshu Rajnish Sharma; Charan, S.; Silva, I.

    2004-01-01

    Introduction: Small intestine is the longest part of gastrointestinal tract. Intra-luminal haemorrhage occurring anywhere in its long and tortuous course is difficult to trace. It is relatively inaccessible to endoscopic evaluation. Upper GI endoscopy can see only up to distal duodenum, whereas colonoscope can view maximum of 30 centimeters of terminal ileum after negotiating the scope through ileo-caecal valve. Hence, localization of bleeding source from small bowel remains a difficult clinical problem. This group of patients can be evaluated with scintigraphy for localizing the site of bleeding before undergoing either angiography or surgery. To our best of knowledge, there is no study, which has utilized scintigraphy for evaluation of small bowel bleed exclusively. The present study has been designed to know the efficacy of 99mTc-RBC scintigraphy in detecting small bowel bleed and to know whether it can differentiate between jejunal and ileal bleeding ? Materials and methods: Thirteen patients presenting with lower gastrointestinal bleeding (malena) were enrolled for the study. In all cases, upper GI endoscopy (UGIE) was unremarkable. Colonoscopic examination was either negative or suspected bleeding occurring proximal to ileo-caecal valve. Thus, in these patients, it is presumed clinically that bleeding is originating from small bowel. Barium meal follow through (BMFT) studies, however, could not delineate any etiological lesion in these patients. There were 8 men and 5 women (mean age 48 years). All patients were anemic (Hb- 6 gm%) and mean 3 units of blood were transfused.These patients were subjected to Tc-99m labeled red blood cells scintigraphy (15 mci, in-vivo method) for localization of source of bleeding. The scintiscan was acquired in two phases. A first pass phase acquired at a rate of 2 seconds per frame for 60 seconds followed by acquisition of static abdominal images (500 K, 256 x 256 matrix) at 5 minutes intervals up to 90 minutes on LFOV gamma

  9. Scintigraphic measurements of the heart-blood-pool in dialyzed chronic uremic patients

    International Nuclear Information System (INIS)

    Nagy, E.S.; Nemessanyi, Z.; Narai, G.; Szegedi Orvostudomanyi Egyetem; Szegedi Orvostudomanyi Egyetem

    1976-01-01

    The authors have carried out scintigraphic measurements of the heart in order to diagnose the presence of an exudative pericarditis 50 times in 26 dialyzed uremic patients. Within the one year's observation 13 patients had an exudative pericarditis from the beginning on. In 8 cases a regression of the exudation could be observed. The examination has a low risk for the patient and is suitable to demonstrate clinically relevant pericardial liquid accumulation. (orig.) [de

  10. Gamma-ray isotopic analysis development at Los Alamos

    Energy Technology Data Exchange (ETDEWEB)

    Thomas E. Sampson

    1999-11-01

    This report describes the development history and characteristics of software developed in the Safeguards Science and Technology group at Los Alamos for gamma-ray isotopic analysis. This software analyzes the gamma-ray spectrum from measurements performed on actinide samples (principally plutonium and uranium) of arbitrary size, geometry, and physical and chemical composition. The results are obtained without calibration using only fundamental tabulated nuclear constants. Characteristics of the current software versions are discussed in some detail and many examples of implemented measurement systems are shown.

  11. Development of advanced sensing system for antipersonnel mines with neutron capture gamma-ray analysis

    International Nuclear Information System (INIS)

    Iguchi, Tetsuo

    2006-01-01

    Neutron induced prompt gamma-ray analysis (NPGA) for survey of antipersonnel landmines is developed. A concept of sensor system with compact strong accelerator neutron source, simulation of detection and simulation results by trial examinations are stated. The measurement principles, objects, system construction, development of compact accelerator neutron source and high performance neutron capture gamma-ray detector, simulation of detection of landmine are reported. It can detect 10.8 MeV gamma-rays and estimate the incident angle of gamma-ray. Schematic layouts of the compact accelerator neutron resource, the compact Compton gamma camera and sensor unit, the estimation principle of incident angle of gamma-ray, experiments and comparison between the experimental results and the estimation results, a preliminary trial experiment system for sensing antipersonnel mines with neutron capture gamma-ray analysis are illustrated. (S.Y.)

  12. Scintigraphical analyses of pulmonary function in dogs

    International Nuclear Information System (INIS)

    Clercx, C.

    1988-01-01

    The main goal of this study was to develop a quantitative analysis from 99mTc aerosol inhalation/perfusion (I/P) lung scintigrams. In particular attention was focused on both the regional I/P distribution, concerning the ratio of the mean I and P values in several lung regions, as well as on the local (intraregional) distribution of I/P, under a wide range of circumstances. In Ch. 2, the method and reference material are described. The distribution of the inhalation-to-perfusion ratios (I/P) is studied in anesthetized healthy dogs, with emphasis on inter-regional distribution and intra-regional dispersion of the I/P ratio. Moreover, it provides an insight into canine pulmonary physiology, frequently transposed from human lung physiology, what is not always correct. Ch. 3 deals with the possible methodological and physiological influences on the interpretation of scintigraphical measurements, such as age, posture and breed. Investigation of the effects of age and breed was pursued using qualitative studies of canine lung surfactant. The actual knowledge in this field lets prospect veterinary clinical meaning in the future. Finally in Ch. 4, the diagnostic value of the measurements was examined in experimental models of important lung disorders with different pathophysiological features, such as lobar and sublobar airway obstruction, and lung embolism. It also permits the investigation of the relative contribution of different compensating mechanisms upon the ventilation-to-perfusion ratio, such as collateral ventilation and hypoxic vasoconstriction. 218 refs.; 31 figs.; 14 tabs

  13. Recent improvements in plutonium gamma-ray analysis using MGA

    International Nuclear Information System (INIS)

    Ruhter, W.D.; Gunnink, R.

    1992-06-01

    MGA is a gamma-ray spectrum analysis program for determining relative plutonium isotopic abundances. It can determine plutonium isotopic abundances better than 1% using a high-resolution, low-energy, planar germanium detector and measurement times ten minutes or less. We have modified MGA to allow determination of absolute plutonium isotopic abundances in solutions. With calibration of a detector using a known solution concentration in a well-defined sample geometry, plutonium solution concentrations can be determined. MGA can include analysis of a second spectrum of the high-energy spectrum to include determination of fission product abundances relative to total plutonium. For the high-energy gamma-ray measurements we have devised a new hardware configuration, so that both the low- and high-energy gamma-ray detectors are mounted in a single cryostat thereby reducing weight and volume of the detector systems. We describe the detector configuration, and the performance of the MGA program for determining plutonium concentrations in solutions and fission product abundances

  14. Analysis of gamma irradiated pepper constituents, 5

    International Nuclear Information System (INIS)

    Takagi, Kazuko; Okuyama, Tsuneo; Ishikawa, Toshihiro.

    1988-01-01

    Gamma irradiated peppers (10 krad, 100 krad, 1 Mrad) were analyzed by HPLC. The extraction method and HPLC conditions were same as the first report, that is, the extraction from pepper was performed by Automatic Air Hammer and the extracted samples were separated on a reversed phase C 8 column with a concave gradient from 0.1% trifluoro aceticacid (TFA) in water to 75% acetonitrile-0.1% TFA in water for 60 minutes and detected at 210 nm, 280 nm. It is difficult to compare with irradiated and unirradiated pepper constituents by their peak height or area. And the method of multi variant statistically analysis was introduced. The 'peak n area/peak n + 1 area' ratio was calculated by computer. Each peak area was accounted by integrator. The value of these ratio were called 'parameter'. Each chromatogram has 741 parameters calculated with 39 chromatographic peaks. And these parameters were abopted to the multi variant statiscally analysis. Comparison of constituents between irradiated pepper and unirradiated pepper was done by 741 parameters. The correlation of parameters between irradiated and unirradiated was investigated by use of computer. Some parameters of irradiated case were selected as which had no correlation with unirradiated case. That is to say these parameters were thought to be changed with gamma spectrum irradiation. By this method, Coumarin was identified as a changed component with gamma irradiation. (author)

  15. A proposal to study the esophageal transit by biomagnetic and scintigraphic study

    International Nuclear Information System (INIS)

    Daghastanli, N.A.; Braga, F.J.H.N.; Baffa, O.

    1996-01-01

    The initial results for a new apparatus to study the esophageal transit time is studied in asymptomatic persons for a yogurt bolus (10 ml). The bolus is uniformly labeled with 5 g of ferrite powder (biomagnetic study, B) or 350 MBq of 99m Tc (scintigraphic study, C). For the B study the detection is made by means two pair of coils in opposite phase excited by a 10 k Hz sinusoidal voltage. The signal response is obtained when the bolus traverses the coils placed on the regions-of-interest (ROIs) of the esophagus (furcula, F and xiphoid process, X) and produces a signal voltage that is measured by a lock-in amplifier Stanford SR530. For C studies an Orbiter Siemens scintillation camera is used linked to a computer. The data analysis shows a (4.1±0.7)s in B studies and (3.7±0.9)s in C studies (R=0.6, P<0.07)

  16. Quantitative portable gamma-spectroscopy sample analysis for non-standard sample geometries

    International Nuclear Information System (INIS)

    Ebara, S.B.

    1998-01-01

    Utilizing a portable spectroscopy system, a quantitative method for analysis of samples containing a mixture of fission and activation products in nonstandard geometries was developed. This method was not developed to replace other methods such as Monte Carlo or Discrete Ordinates but rather to offer an alternative rapid solution. The method can be used with various sample and shielding configurations where analysis on a laboratory based gamma-spectroscopy system is impractical. The portable gamma-spectroscopy method involves calibration of the detector and modeling of the sample and shielding to identify and quantify the radionuclides present in the sample. The method utilizes the intrinsic efficiency of the detector and the unattenuated gamma fluence rate at the detector surface per unit activity from the sample to calculate the nuclide activity and Minimum Detectable Activity (MDA). For a complex geometry, a computer code written for shielding applications (MICROSHIELD) is utilized to determine the unattenuated gamma fluence rate per unit activity at the detector surface. Lastly, the method is only applicable to nuclides which emit gamma-rays and cannot be used for pure beta or alpha emitters. In addition, if sample self absorption and shielding is significant, the attenuation will result in high MDA's for nuclides which solely emit low energy gamma-rays. The following presents the analysis technique and presents verification results using actual experimental data, rather than comparisons to other approximations such as Monte Carlo techniques, to demonstrate the accuracy of the method given a known geometry and source term. (author)

  17. Clinical, radiographic and scintigraphic aspects of the trapeziometacarpal osteoarthritis

    International Nuclear Information System (INIS)

    Kaziyama, Helena Hideko Seguchi

    1996-01-01

    Trapeziometacarpal osteoarthritis occurs mainly in women during the menopausal period. It is related to manual activities and is usually bilateral. The onset is insidious and the evolution is slow and progressive. It is characterized by of strength and pain in the basis of the thumb resulting in limitation of the use and function of the hand. The diagnosis of this condition is based on the physical examination. The manouver of compression axial-rotation of the trapezimetacarpal joint is a common positive finding. Typical findings of osteoarthritis are present in the radiological studies. Scintigraphic images have a predictive value. The early diagnosis is important to avoid the risk factors and to prevent disabilities of the hand. (author)

  18. Innovative research reactor core designed. Estimation and analysis of gamma heating distribution

    International Nuclear Information System (INIS)

    Setiyanto

    2014-01-01

    The Gamma heating value is an important factor needed for safety analysis of each experiments that will be realized on research reactor core. Gamma heat is internal heat source occurs in each irradiation facilities or any material irradiated in reactor core. This value should be determined correctly because of the safety related problems. The gamma heating value is in general depend on. reactor core characteristics, different one and other, and then each new reactor design should be completed by gamma heating data. The Innovative Research Reactor is one of the new reactor design that should be completed with any safety data, including the gamma heating value. For this reasons, calculation and analysis of gamma heating in the hole of reactor core and irradiation facilities in reflector had been done by using of modified and validated Gamset computer code. The result shown that gamma heating value of 11.75 W/g is the highest value at the center of reactor core, higher than gamma heating value of RSG-GAS. However, placement of all irradiation facilities in reflector show that safety characteristics for irradiation facilities of innovative research reactor more better than RSG-GAS reactor. Regarding the results obtained, and based on placement of irradiation facilities in reflector, can be concluded that innovative research reactor more safe for any irradiation used. (author)

  19. Scintigraphic findings in amoebic abscess of the liver

    International Nuclear Information System (INIS)

    Buenemann, H.; Petersen, F.; Mohr, W.

    1976-01-01

    The accuracy, size, localization and course of liver scans of solitary or multiple amoebic liver abscesses was evaluated in 52 patients. The scintigraphic data were correlated with the clinical symptoms. In 47 of the 52 patients it was possible to demonstrate the liver abscess on the scintigram; the right lobe of the liver was involved more frequently than would have been expected simply on the basis of its volume. In most of the patients investigated the abscesses were solitary and in only 28% it was possible to recognise two or three abscesses occurring simultaneously. Follow-up examinations showed rapid diminution in the size of the abscess during medical treatment, but complete return to normal during the first six months occured in only 17% of cases. The results are discussed. (orig.) [de

  20. Epiphyseal involvement in Erdheim-Chester disease: radiographic and scintigraphic findings in a case with lytic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz-Hernandez, G.; Tajahuerce-Romera, G.M.; Latorre-Ibanez, M.D.; Lara-Pomares, A. [Servicio de Medicina Nuclear, Hospital Provincial de Castellon (Spain); Vila-Fayos, V. [Servicio de Reumatologia, Hospital Comarcal de Vinaroz (Spain)

    2000-08-01

    We reported a symmetric increase of activity in lower links secondary to Erdheim-Chester disease and demonstrated by bone scans and radiographs. An inusual scintigraphic and radiographic appearance with epiphyseal involvement and lytic lesions is described. Differential diagnosis of bone scan and radiographic findings is discussed. (orig.)

  1. Methods for the analysis of the overlapped peaks in analytical gamma-spectrometry

    International Nuclear Information System (INIS)

    Sterlinski, S.; Wasek, M.

    1989-01-01

    A new simple method for the quantitative analysis of the doublet peaks in Ge(Li) or HPGe gamma-spectrometry is presented. No assumptions on the shape of the peaks in gamma-ray spectra being measured are required. Special feature of the method proposed is its usefulness for the analysis of closed doublets. 7 refs., 6 figs. (author)

  2. Non destructive multi elemental analysis using prompt gamma neutron activation analysis techniques: Preliminary results for concrete sample

    Energy Technology Data Exchange (ETDEWEB)

    Dahing, Lahasen Normanshah [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor, Malaysia and Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia); Yahya, Redzuan [School of Applied Physics, Universiti Kebangsaan Malaysia, 43600 Bangi, Selangor (Malaysia); Yahya, Roslan; Hassan, Hearie [Malaysian Nuclear Agency (Nuklear Malaysia), Bangi 43000, Kajang (Malaysia)

    2014-09-03

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10×10×10 cm{sup 3} and 15×15×15 cm{sup 3} were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with NAA and XRF techniques as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed.

  3. Artificial neural networks application for analysis of gamma ray spectrum obtained from the scintillation detectors

    International Nuclear Information System (INIS)

    Stegowski, Z.

    2002-01-01

    Scintillation detectors are commonly used for the gamma ray detection. Actually the small peak resolution and the significant Compton effect fraction limit their utilization in the gamma ray spectrometry analysis. This article presents the artificial neural networks (ANN) application to the analysis of the gamma ray spectra acquired from scintillation detectors. The obtained results validate the effectiveness of the ANN method to spectrometry analysis. (author)

  4. Imaging of heterogeneous materials by prompt gamma-ray neutron activation analysis

    International Nuclear Information System (INIS)

    Staples, Parrish; Prettyman, Tom; Lestone, John

    1999-01-01

    We have used a Tomographic Gamma Scanner (TGS) to produce tomographic Prompt Gamma-Ray Neutron Activation Imaging of heterogeneous matrices [T.H. Prettyman, R.J. Estep, G.A. Sheppard, Trans. Am. Nucl. Soc. 69 (1993) 183-184]. The TGS was modified by the addition of graphite reflectors that contain isotopic neutron sources for sample interrogation. We are in the process of developing the analysis methodology necessary for a quantitative assay of large containers of heterogeneous material. This nondestructive analysis technique can be used for material characterization and the determination of neutron assay correction factors. The most difficult question to be answered is the determination of the source to sample coupling term. To assist in the determination of the coupling term we have obtained images for a range of samples that are very well characterized; such as, homogenous pseudo one-dimensional samples to three-dimensional heterogeneous samples. We then compare the measurements to Monte Carlo N-particle calculations. For an accurate quantitative measurement it is also necessary to determine the sample gamma-ray self attenuation at higher gamma-ray energies, namely pair production should be incorporated into the analysis codes

  5. Application of neutron-gamma analysis for determination of C/N ratio in compost

    Science.gov (United States)

    Neutron-gamma analysis is based on the acquisition of gamma rays from neutron irradiated study objects. The intensity and energy of the registered gamma rays gives information on the types and amounts of elements in the studied object. The use of this method for measurements of soil carbon demonstra...

  6. Scintigraphic test of the vitality and functional fitness of organs conserved for transplantation

    International Nuclear Information System (INIS)

    Bozduganov, A.; Marinov, V.

    1976-01-01

    Having reviewed critically present-day methods of testing the vitality of isolated perfused organs, the authors propose their own. It is founded in the principles of colour scintigraphy after introduction of short-lived nuclides. The method was applied in testing 57 isolated preserved organs (5 kidneys, 12 livers, 5 hearts and 4 spleens from dogs; 2 kidneys and 27 livers from rabbits; 1 kidney and 1 liver from young pigs). Moreover, compararive scintigraphic and biochemical investigations were conducted on 2 dogs and 4 young pigs (A. Bozduganov, E. Simeonov, N. Bogdanova). The techniques of isolation and perfusion of the organ have been given a detailed description. Sup(113m)In was used as tracer. Areas of radioactivity deposits were visualized more or less intensely, depending on the degree of vitality and functional fitness still present actually; else, blanks were seen. Orthotransplantation and heterotransplantation with subsequent scintigraphic examination in vivo served, in scattered instances, the purpose of confirming or of rejecting ambiguous vitality findings in preserved organs. Advantages of the method are a general and specified evaluation of the organ in all of its areas; anatomical integrity of the object under test; applicability to various organs; possibility of conducting dynamic tests; accurate reproduction of vitality and functional findings, etc

  7. Scintigraphic assessment of colostomy irrigation.

    Science.gov (United States)

    Christensen, P.; Olsen, N.; Krogh, K.; Laurberg, S.

    2002-09-01

    OBJECTIVE: This study aims to evaluate colonic transport following colostomy irrigation with a new scintigraphic technique. MATERIALS AND METHODS: To label the bowel contents 19 patients (11 uncomplicated colostomy irrigation, 8 complicated colostomy irrigation) took 111In-labelled polystyrene pellets one and two days before investigation. 99mTc-DTPA was mixed with the irrigation fluid to assess its extent within the bowel. Scintigraphy was performed before and after a standardized washout procedure. The colon was divided into three segments 1: the caecum andascending colon; 2: the transverse colon; 3: the descending and sigmoid colon. Assuming ordered evacuation of the colon, the contribution of each colonic segment to the total evacuation was expressed as a percentage of the original segmental counts. These were added to reach a total defaecation score (range: 0-300). RESULTS: In uncomplicated colostomy irrigation, the median defaecation score was 235 (range: 145-289) corresponding to complete evacuation of the descending and transverse colon and 35% evacuation of the caecum/ascending colon. In complicated colostomy irrigation it was possible to distinguish specific emptying patterns. The retained irrigation fluid reached the caecum in all but one patient. CONCLUSION: Scintigraphy can be used to evaluate colonic emptying following colostomy irrigation.

  8. Derivative based sensitivity analysis of gamma index

    Directory of Open Access Journals (Sweden)

    Biplab Sarkar

    2015-01-01

    Full Text Available Originally developed as a tool for patient-specific quality assurance in advanced treatment delivery methods to compare between measured and calculated dose distributions, the gamma index (γ concept was later extended to compare between any two dose distributions. It takes into effect both the dose difference (DD and distance-to-agreement (DTA measurements in the comparison. Its strength lies in its capability to give a quantitative value for the analysis, unlike other methods. For every point on the reference curve, if there is at least one point in the evaluated curve that satisfies the pass criteria (e.g., δDD = 1%, δDTA = 1 mm, the point is included in the quantitative score as "pass." Gamma analysis does not account for the gradient of the evaluated curve - it looks at only the minimum gamma value, and if it is <1, then the point passes, no matter what the gradient of evaluated curve is. In this work, an attempt has been made to present a derivative-based method for the identification of dose gradient. A mathematically derived reference profile (RP representing the penumbral region of 6 MV 10 cm × 10 cm field was generated from an error function. A general test profile (GTP was created from this RP by introducing 1 mm distance error and 1% dose error at each point. This was considered as the first of the two evaluated curves. By its nature, this curve is a smooth curve and would satisfy the pass criteria for all points in it. The second evaluated profile was generated as a sawtooth test profile (STTP which again would satisfy the pass criteria for every point on the RP. However, being a sawtooth curve, it is not a smooth one and would be obviously poor when compared with the smooth profile. Considering the smooth GTP as an acceptable profile when it passed the gamma pass criteria (1% DD and 1 mm DTA against the RP, the first and second order derivatives of the DDs (δD', δD" between these two curves were derived and used as the

  9. Evaluation of quatitative scintigraphic method in diagnosis of esophagic involvement of Progressive Systemic Sclerosis

    International Nuclear Information System (INIS)

    Von Muehlen, C.A.

    1985-01-01

    Twenty patients with Progressive Systemic Sclerosis are studied by scintigraphic methodology. The esophageal transit method is used for liquid and solid meals. The results are compared with the ones of a control group, without or not gastrintestinal problems but without autoimmune diasese. 99 sup(m)Tc-sulfurcolloid is used as labelling compound. The studies were done in supine and orthostatical position. (M.A.C.) [pt

  10. Methodology for Quantitative Analysis of Large Liquid Samples with Prompt Gamma Neutron Activation Analysis using Am-Be Source

    International Nuclear Information System (INIS)

    Idiri, Z.; Mazrou, H.; Beddek, S.; Amokrane, A.

    2009-01-01

    An optimized set-up for prompt gamma neutron activation analysis (PGNAA) with Am-Be source is described and used for large liquid samples analysis. A methodology for quantitative analysis is proposed: it consists on normalizing the prompt gamma count rates with thermal neutron flux measurements carried out with He-3 detector and gamma attenuation factors calculated using MCNP-5. The relative and absolute methods are considered. This methodology is then applied to the determination of cadmium in industrial phosphoric acid. The same sample is then analyzed by inductively coupled plasma (ICP) method. Our results are in good agreement with those obtained with ICP method.

  11. Spreadsheet analysis of gamma spectra for nuclear material measurements

    International Nuclear Information System (INIS)

    Mosby, W.R.; Pace, D.M.

    1990-01-01

    A widely available commercial spreadsheet package for personal computers is used to calculate gamma spectra peak areas using both region of interest and peak fitting methods. The gamma peak areas obtained are used for uranium enrichment assays and for isotopic analyses of mixtures of transuranics. The use of spreadsheet software with an internal processing language allows automation of routine analysis procedures increasing ease of use and reducing processing errors while providing great flexibility in addressing unusual measurement problems. 4 refs., 9 figs

  12. The scintigraphic reaction pattern of traumatic bone lesions

    International Nuclear Information System (INIS)

    Spitz, J.

    1994-01-01

    The indications for bone scintigraphy in traumatology result: 1. Definite exclusion of bone lesions by normal scintigraphic findings (except for the scull). 2. Unclear result of X-ray or a mismatch between clinical investigation and X-ray result. 3. Screening after multiple injury which leads to the detection of an unknown bone lesion in every second patient. 4. Suspicion of a complicated healting course in cases of doubtful X-ray results. 5. The estimation of relative fracture age. This question always rises, if a pre-existing trauma or morphologic changes in X-ray make a clear diagnosis impossible. The additional information gained by bone scintigraphy is in part exclusive and not to be drawn from any other imaging modality. This renders bone scintigraphy to an important tool in the work up of medico-legal questions in traumatology. (orig.) [de

  13. Application of prompt gamma-ray activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Yong Sam; Park, Kwang Won; Moon, Jong Hwa; Kim, Sun Ha; Baek, Sung Ryel [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-03-01

    This technical report is written for the promotion to utilization of prompt gamma-ray activation analysis facility to be installed in HANARO reactor. It is described for a practical aspects including experiment and equipments, methodology, current status of the research and development and its applications. 102 refs., 32 figs., 25 tabs. (Author)

  14. Sjoegren's syndrome. A functional scintigraphic study of salivary glands

    International Nuclear Information System (INIS)

    Arrago, J.P.; Rain, J.D.; Rocher, F.; Vigneron, N.; Pecking, A.; Najean, Y.

    1984-01-01

    One-hundred and twenty patients with sicca syndrome, connective tissue disease or chronic graft-versus-host disease were investigated in the Saint-Louis Hospital Department of Nuclear Medicine. Technetium scanning of the salivary glands was performed in all patients. The results of the scintigraphic study were closely correlated with clinical and histological data in patients with Sjoegren's syndrome. This method, which accurately quantifies the salivary function without danger nor discomfort to the patients, has a number of advantages: (a) it is sensitive enough to detect minimal salivary gland dysfunction; (b) it differentiates between parotid gland and submandibular gland involvement demonstrates assymetry in pathological processes; (c) it helps in following up patients with Sjoegren's disease and in assessing the results of immunosuppressive or anti-inflammatory treatment [fr

  15. Computational analysis of kidney scintigrams

    Energy Technology Data Exchange (ETDEWEB)

    Vrincianu, D.; Puscasu, E.; Creanga, D. [University Al. I. Cuza, Faculty of Physics, 11 Blvd. Carol I, 700506, Iasi (Romania); Stefanescu, C. [University of Medicine and Pharmacy Gr. T. Popa, Iasi (Romania)

    2013-11-13

    The scintigraphic investigation of normal and pathological kidneys was carried out using specialized gamma-camera device from nuclear medicine hospital department. Technetium 90m isotope with gamma radiation emission, coupled with vector molecules for kidney tissues was introduced into the subject body, its dynamics being recorded as data source for kidney clearance capacity. Two representative data series were investigated, corresponding to healthy and pathological organs respectively. The semi-quantitative tests applied for the comparison of the two distinct medical situations were: the shape of probability distribution histogram, the power spectrum, the auto-correlation function and the Lyapunov exponent. While power spectrum led to similar results in both cases, significant differences were revealed by means of distribution probability, Lyapunov exponent and correlation time, recommending these numerical tests as possible complementary tools in clinical diagnosis.

  16. High resolution gamma-ray spectroscopy applied to bulk sample analysis

    International Nuclear Information System (INIS)

    Kosanke, K.L.; Koch, C.D.; Wilson, R.D.

    1980-01-01

    A high resolution Ge(Li) gamma-ray spectrometer has been installed and made operational for use in routine bulk sample analysis by the Bendix Field Engineering Corporation (BFEC) geochemical analysis department. The Ge(Li) spectrometer provides bulk sample analyses for potassium, uranium, and thorium that are superior to those obtained by the BFEC sodium iodide spectrometer. The near term analysis scheme permits a direct assay for uranium that corrects for bulk sample self-absorption effects and is independent of the uranium/radium disequilibrium condition of the sample. A more complete analysis scheme has been developed that fully utilizes the gamma-ray data provided by the Ge(Li) spectrometer and that more properly accounts for the sample self-absorption effect. This new analysis scheme should be implemented on the BFEC Ge(Li) spectrometer at the earliest date

  17. Development of prompt gamma activation analysis

    International Nuclear Information System (INIS)

    Olmez, I.

    1982-01-01

    Application of prompt gamma-activation analysis to some environmental samples and NBS's standard reference materials were examined, using NBS reactor and the technique developed by the nuclear chemistry group of the University of Maryland. Concentration of several elements, Cd, B, S, Se, Sb, Zn, Ba, Cr, Cs, Co, Si, Hf, Ce, Yb, Lu, Th, Sc, Eu, Fe, Ta and Rb, were determined by both PGAA and INAA. (author)

  18. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Certain, D.A.; Brolio, R.; Salomon, G.C.; Carvalho, N.; Barbosa, Z.L.M.

    1972-01-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin 131 I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions [pt

  19. Scintigraphic study of blood perfusion of the pulmonary artery in pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Certain, D A; Brolio, R; Salomon, G C [Sao Paulo Univ. (Brazil). Faculdade de Saude Publica; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear; Barbosa, Z L.M. [Associacao dos Sanatorios Populares de Campos do Jordao, Brazil

    1972-10-01

    Blood perfusion in the pulmonary artery is studied by pulmonary scintigraphy with macroaggregated albumin /sup 131/I, in 74 cases of pulmonary tuberculosis. Results shown by scintigraphy are compared to those observed in roentgenography and also correlated with the extension and degree of the lesions, and with the presence of associated tuberculosis, considered capable of changing the scintigraphic picture. The reduction of blood flow in the pulmonary artery are observed in cases of infiltrative, fibrotic of caseous lesions, as well as in cases of minor lesions.

  20. In vitro evaluation, biodistribution and scintigraphic imaging in mice of radiolabeled anthrax toxins

    International Nuclear Information System (INIS)

    Dadachova, Ekaterina; Rivera, Johanna; Revskaya, Ekaterina; Nakouzi, Antonio; Cahill, Sean M.; Blumenstein, Michael; Xiao, Hui; Rykunov, Dmitry; Casadevall, Arturo

    2008-01-01

    Introduction: There is a lot of interest towards creating therapies and vaccines for Bacillus anthracis, a bacterium which causes anthrax in humans and which spores can be made into potent biological weapons. Systemic injection of lethal factor (LF), edema factor (EF) and protective antigen (PA) in mice produces toxicity, and this protocol is commonly used to investigate the efficacy of specific antibodies in passive protection and vaccine studies. Availability of toxins labeled with imageable radioisotopes would allow to demonstrate their tissue distribution after intravenous injection at toxin concentration that are below pharmacologically significant to avoid masking by toxic effects. Methods: LF, EF and PA were radiolabeled with 188 Re and 99m Tc, and their performance in vitro was evaluated by macrophages and Chinese hamster ovary cells toxicity assays and by binding to macrophages. Scintigraphic imaging and biodistribution of intravenously (IV) injected 99m Tc-and 123 I-labeled toxins was performed in BALB/c mice. Results: Radiolabeled toxins preserved their biological activity. Scatchard-type analysis of the binding of radiolabeled PA to the J774.16 macrophage-like cells revealed 6.6x10 4 binding sites per cell with a dissociation constant of 6.7 nM. Comparative scintigraphic imaging of mice injected intravenously with either 99m Tc-or 123 I-labeled PA, EF and LF toxins demonstrated similar biodistribution patterns with early localization of radioactivity in the liver, spleen, intestines and excretion through kidneys. The finding of renal excretion shortly after IV injection strongly suggests that toxins are rapidly degraded which could contribute to the variability of mouse toxigenic assays. Biodistribution studies confirmed that all three toxins concentrated in the liver and the presence of high levels of radioactivity again implied rapid degradation in vivo. Conclusions: The availability of 188 Re and 99m Tc-labeled PA, LF and EF toxins allowed us to

  1. Principle and preliminary results of the whole-body scintigraphic unit Omniview

    International Nuclear Information System (INIS)

    Methlin, G.; Jung, G.M.; Gerard, G.

    The Picker Company has recently launched a system adapted to its Dynacamera for the production of whole-body scintigraphs. For the last few months the radioisotopes service of the Strasbourg Anti-Cancer Centre has been in possession of such a system, intended mainly for systematic research on metastases, especially of the bone, and on the degree of extension of tumours. On the basis of the short experience so far acquired the report is limited to an outline of the working principle of this device, the presentation of preliminary documents and a few critical remarks summing up first impressions [fr

  2. Application of full spectrum analysis technique for NaI(TI) based gamma ray spectral monitoring system

    International Nuclear Information System (INIS)

    Pant, Amar D.; Verma, Amit K.; Narayani, K.; Anilkumar, S.; Singh, Rajvir

    2016-01-01

    NaI(Tl) is commonly used for the gamma spectrometry analysis in laboratories. It continues to be the first choice for gamma spectrometry in many applications even today. Many gamma spectrometric methods are developed to experimentally determine activity of radionuclides in samples. Detectors used worldwide for gamma radiation monitoring are either GM based or scintillator based detector based on count rate. For radiation early warning systems radionuclide specific radiation monitoring methodology is required i.e. gamma ray spectrometry based environmental monitoring system. A computer program has been developed for gamma spectral monitoring by the use of full spectrum analysis (FSA). In this measured spectra are fitted using individual spectral components by least square fitting (LSF). The method is found very useful in situations, where radionuclide specific environmental radiation monitoring is required. The paper describes the details of the FSA procedure for the on line acquisition and analysis of gamma ray spectra from Nal(Tl) detectors

  3. Visual gamma-ray analysis. VIPF program (WINDOW 95)

    International Nuclear Information System (INIS)

    Yamada, S.

    1998-01-01

    VIsual Peak Fitting (VIPF) program for the analysis of gamma radiation peaks from Ge detectors which works on WINDOWS 95 as an operating system has been developed. Gamma-ray peaks are simulated as Gauss function with 1st- or 2nd-order polynomial function for the background spectrum. Any function can be further added to for parameter fitting. The VIPF program can be obtained through internet by down-loading: http://w3.rri.kyoto-u.ac.jp/~yamada. Details of the program procedure, explanation of the fitting function to be used and peak search routine, and manuals of the code are given. (Ohno, S.)

  4. Scintigraphic criteria for administration of therapeutic activities of 131I for ablation of residual thyroid tissue in patients with differentiated thyroid cancer

    International Nuclear Information System (INIS)

    Dzhuzha, D.A.

    2003-01-01

    With the aim to determinate the optical scintigraphic criteria of radioablation of the small parts of residual thyroid tissue (RTT) after a thyroidectomy the results of postoperative monitoring of 29 women aged 23-60 with differentiated thyroid cancer, who did not get the radioiodine therapy, were analyzed. At the single postoperative scintigraphy with 131 I the optimal scintigraphic criteria for radioablation are the relative level of 131 I accumulation in RTT and the relative specific volume activity in RTT. At the values of these indices below 0.21% and 0.16%/sm 3 , respectively, only suppressive thyroid hormone therapy and standard monitoring are recommended

  5. EBT-P gamma-ray-shielding analysis

    International Nuclear Information System (INIS)

    Gohar, Y.

    1983-01-01

    First, a one-dimensional scoping study was performed for the gamma-ray shield of the ELMO Bumpy Torus proof-of-principle device to define appropriate shielding material and determine the required shielding thickness. The dose-equivalent results are analyzed as a function of the radiation-shield thickness for different shielding options. A sensitivity analysis for the pessimistic case is given. The recommended shielding option based on the performance and cost is discussed. Next, a three-dimensional scoping study for the coil shield was performed for four different shielding options to define the heat load for each component and check the compliance with the design criterion of 10 watts maximum heat load per coil from the gamma-ray sources. Also, a detailed biological-dose survey was performed which included: (a) the dose equivalent inside and outside the building, (b) the dose equivalent from the two mazes of the building, and (c) the skyshine contribution to the dose equivalent

  6. NEPHRUS: model of intelligent multilayers expert system for evaluation of the renal system based on scintigraphic images analysis; NEPRUS: modelo de sistema especialista em multicamadas inteligentes para avaliacao do sistema urinario baseado na analise de imagens cintilograficas

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Jose W.E. da; Schirru, Roberto [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia; Boasquevisque, Edson M. [Universidade do Estado, Rio de Janeiro, RJ (Brazil). Servico de Medicina Nuclear

    1997-10-01

    This work develops a prototype for the system model based on Artificial Intelligence devices able to perform functions related to scintigraphic image analysis of the urinary system. Criteria used by medical experts for analysis images obtained with {sup 99m} Tc+DTPA and/or {sup 99m} Tc+DMSA were modeled and a multi resolution diagnosis technique was implemented. Special attention was given to the programs user interface design. Human Factor Engineering techniques were considered so as to ally friendliness and robustness. Results obtained using Artificial Neural Networks for the qualitative image analysis and the knowledge model constructed shows the feasibility of Artificial Intelligence implementation that use `inherent` abilities of each technique in the resolution of diagnosis image analysis problems. (author). 12 refs., 2 figs., 2 tabs.

  7. 123I-BMIPP delayed scintigraphic imaging in patients with chronic heart failure.

    Science.gov (United States)

    Kida, Keisuke; Akashi, Yoshihiro J; Yoneyama, Kihei; Shimokawa, Mitsuhiro; Musha, Haruki

    2008-11-01

    The objective of the present study was to clarify the ability of 123I-beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) to evaluate the heart-to-mediastinum (H/M) ratio and myocardial global washout rate (WR) in patients with chronic heart failure (CHF). The severity of CHF was evaluated on the basis of the New York Heart Association (NYHA) classification. Twenty patients with CHF (13 with idiopathic dilated cardiomyopathy and 7 with ischemic cardiomyopathy) and 11 age-matched controls underwent myocardial radionuclide imaging. Scintigraphic images were obtained from each participant at the early (30 min following radio-isotope injection) and late (4 h) phases using 123I-BMIPP. The H/M ratio and WR were calculated from planar images. Concentrations of plasma brain natriuretic peptide (BNP) were measured prior to the scintigraphic study. The 123I-BMIPP uptake of early H/M and global WR did not significantly differ among groups, but uptake of delayed H/M was significantly lower in patients with NYHA class III than in controls (control 2.47 +/- 0.39; class III 1.78 +/- 0.28, P < 0.05). The uptake of delayed H/M and global WR correlated with plasma log BNP in all participants (r = -0.38, P < 0.05; 0.43, P < 0.05, respectively). These data suggest that 123I-BMIPP uptake of delayed H/M enhances the image of CHF severity. The myocardial WR of 123I-BMIPP also effectively depicted the severity of CHF.

  8. Dynamic renal scintigraphic estimation of deceased donor kidneys in a rat model

    Directory of Open Access Journals (Sweden)

    Huseyin Aydin Mitil

    2017-01-01

    Full Text Available At present a large number of the renal transplantations are being performed from the deceased donors. The success of these transplantations depends on the viability of the deceased donor kidneys. The aim of this study was to investigate the reliability of scintigraphic estimation of function of deceased donor kidneys by comparing the histopathologic and scintigraphic findings. Ten rats were included in the study (2–3 months old, 250–300 g, all male. Control scintigraphy was performed to all the rats by injection of 37 MBq Tc-99m DTPA from the tail vein in a dynamic manner. Brain death of the rats was achieved by inflation of a Fogartys catheter in the cranial cavity. Immediately, after brain death confirmation, dynamic renal scintigraphy was performed with the same parameters of control scintigraphy. In the comparison of scintigraphies obtained in the before and just after brain death period, there was impairment of tubular functions, concentration and excretion functions in the postbrain death period. In the immediate postbrain death period, there was a significant elevation in the glomerular filtration rate and time to maximum concentration values. In the histopathological evaluation of the kidney samples in the postbrain death period, there were definitive findings of tubular impairment. Dynamic renal scintigraphy also demonstrated definite impairment of tubular system and tubular functions in the deceased donor kidneys. This could explain the reason of the increased frequency of acute tubular necrosis seen among deceased donor kidneys.

  9. Measurements and analysis of neutron and gamma noise in BWR's

    International Nuclear Information System (INIS)

    Dam, H. van; Kleiss, E.B.J.

    1985-01-01

    Neutron and gamma sensitive collectrons (self-powered detectors) have been designed for incore noise measurements in BWRs. A so-called twin-type has been developed for measurements of two-phase flow characteristics and detailed axial velocity distributions. Construction aspects of the twin detectors are discussed. An analysis is presented of the response of both detector types to incore parametric fluctuations. This analysis is based on detector response functions which provide an insight into the 'field of view' of the two types. The results are supported by experimental verifications; it is shown that incore gamma detectors provide useful additional information about two-phase flow in a BWR. (author)

  10. Scintigraphic imaging of Staphylococcus aureus infection using 99mTc radiolabeled aptamers.

    Science.gov (United States)

    Santos, Sara Roberta Dos; de Sousa Lacerda, Camila Maria; Ferreira, Iêda Mendes; de Barros, André Luís Branco; Fernandes, Simone Odília; Cardoso, Valbert Nascimento; de Andrade, Antero Silva Ribeiro

    2017-10-01

    Staphylococcus aureus is a specie of great medical importance associated with many infections as bacteremia and infective endocarditis as well as osteoarticular, skin and soft tissue, pleuropulmonary, and device related infections. Early identification of infectious foci is crucial for successful treatment. Scintigraphy could contribute to this purpose since specific radiotracers were available. Aptamers due to their high specificity have great potential for radiopharmaceuticals development. In the present study scintigraphic images of S. aureus infectious foci were obtained using specific S. aureus aptamers radiolabeled with 99m Tc. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. ZZ TPASGAM-85, Gamma Spectra Data Library for Activation Analysis

    International Nuclear Information System (INIS)

    1995-01-01

    Description of program or function: Format: for use with RSIC code package PSR-164/TPASS. Nuclides: 1438 radionuclides; Origin: Recently-published results and also from Nuclear Data Sheets and Atomic Data and Nuclear Data Tables. The TPASGAM data library contains gamma-ray decay information for 1438 radionuclides. The data consist of gamma-ray energies and intensities as well as cross section information useful in activation analysis. This compilation of radionuclide decay data contains, for those radionuclides tabulated, all necessary data for qualitatively and quantitatively measuring the concentration of photon emitting radionuclides as well as conducting activation analyses using gamma-ray spectrometry. It was developed specifically for use with RSIC code package PSR-164/TPASS

  12. Portable microcomputer unit for the analysis of plutonium gamma-ray spectra

    International Nuclear Information System (INIS)

    Ruhter, W.D.; Camp, D.C.

    1981-10-01

    A portable microcomputer has been developed for the IAEA to perform in-field analysis of plutonium gamma-ray spectra. The unit includes a 16-bit LSI-11/2 microprocessor, 32K words of memory, a 20-character display for user prompting, and a 20-character thermal printer for hardcopy output. Only the positions of the 148-keV Pu-241 and 208-keV U-237 peaks are required for spectral analysis. The unit was tested against gamma-ray spectra taken of NBS plutonium standards and IAEA spectra. Results obtained are presented

  13. Prompt Gamma Activation Analysis (PGAA): Technique of choice for nondestructive bulk analysis of returned comet samples

    International Nuclear Information System (INIS)

    Lindstrom, D.J.; Lindstrom, R.M.

    1989-01-01

    Prompt gamma activation analysis (PGAA) is a well-developed analytical technique. The technique involves irradiation of samples in an external neutron beam from a nuclear reactor, with simultaneous counting of gamma rays produced in the sample by neutron capture. Capture of neutrons leads to excited nuclei which decay immediately with the emission of energetic gamma rays to the ground state. PGAA has several advantages over other techniques for the analysis of cometary materials: (1) It is nondestructive; (2) It can be used to determine abundances of a wide variety of elements, including most major and minor elements (Na, Mg, Al, Si, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni), volatiles (H, C, N, F, Cl, S), and some trace elements (those with high neutron capture cross sections, including B, Cd, Nd, Sm, and Gd); and (3) It is a true bulk analysis technique. Recent developments should improve the technique's sensitivity and accuracy considerably

  14. An Overview of the XGAM Code and Related Software for Gamma-ray Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Younes, W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-11-13

    The XGAM spectrum-fitting code and associated software were developed specifically to analyze the complex gamma-ray spectra that can result from neutron-induced reactions. The XGAM code is designed to fit a spectrum over the entire available gamma-ray energy range as a single entity, in contrast to the more traditional piecewise approaches. This global-fit philosophy enforces background continuity as well as consistency between local and global behavior throughout the spectrum, and in a natural way. This report presents XGAM and the suite of programs built around it with an emphasis on how they fit into an overall analysis methodology for complex gamma-ray data. An application to the analysis of time-dependent delayed gamma-ray yields from 235U fission is shown in order to showcase the codes and how they interact.

  15. Gamma Splines and Wavelets

    Directory of Open Access Journals (Sweden)

    Hannu Olkkonen

    2013-01-01

    Full Text Available In this work we introduce a new family of splines termed as gamma splines for continuous signal approximation and multiresolution analysis. The gamma splines are born by -times convolution of the exponential by itself. We study the properties of the discrete gamma splines in signal interpolation and approximation. We prove that the gamma splines obey the two-scale equation based on the polyphase decomposition. to introduce the shift invariant gamma spline wavelet transform for tree structured subscale analysis of asymmetric signal waveforms and for systems with asymmetric impulse response. Especially we consider the applications in biomedical signal analysis (EEG, ECG, and EMG. Finally, we discuss the suitability of the gamma spline signal processing in embedded VLSI environment.

  16. The progress of neutron induced prompt gamma analysis technique in 1988-2002

    International Nuclear Information System (INIS)

    Liu Yuren; Jing Shiwei

    2003-01-01

    The new development of the neutron induced prompt gamma-ray analysis (NIPGA) technology in 1988-2002 are described. The pulse fast-thermal neutron activation analysis method, which utilizes the inelastic reaction and capture reaction jointly is employed to measure the elemental content in the material more efficiently. The lifetime of the neutron generator is more than 10000 h and the capability of HPGe, TeZeCd and MCA (multi-channel analyser) reaches the high level. At the same time, Monte Carlo Library least-square method is used to solve the nonlinearity problem in the PGNAA (Prompt Gamma Neutron Activation Analysis)

  17. Improved soil particle-size analysis by gamma-ray attenuation

    International Nuclear Information System (INIS)

    Oliveira, J.C.M.; Vaz, C.M.P.; Reichardt, K.; Swartzendruber, D.

    1997-01-01

    The size distribution of particles is useful for physical characterization of soil. This study was conducted to determine whether a new method of soil particle-size analysis by gamma-ray attenuation could be further improved by changing the depth and time of measurement of the suspended particle concentration during sedimentation. In addition to the advantage of nondestructive, undisturbed measurement by gamma-ray attenuation, as compared with conventional pipette or hydrometer methods, the modifications here suggested and employed do substantially decrease the total time for analysis, and will also facilitate total automation and generalize the method for other sedimentation studies. Experimental results are presented for three different Brazilian soil materials, and illustrate the nature of the fine detail provided in the cumulative particle-size distribution as given by measurements obtained during the relatively short time period of 28 min

  18. Page: a program for gamma spectra analysis in PC microcomputers

    International Nuclear Information System (INIS)

    Goncalves, M.A.; Yamaura, M.; Costa, G.J.C.; Carvalho, E.I. de; Matsuda, H.T.; Araujo, B.F. de.

    1991-04-01

    PAGE is a software package, written in BASIC language, to perform gamma spectra analysis. It was developed to be used in a high-purity intrinsic germanium detector-multichannel analyser-PC microcomputer system. The analysis program of PAGE package accomplishes functions as follows: peak location; gamma nuclides identification; activity determination. Standard nuclides sources were used to calibrate the system. To perform the efficiency x energy calibration a logarithmic fit was applied. Analysis of nuclides with overlapping peaks is allowed by PAGE program. PAGE has additional auxiliary programs for: building and list of isotopic nuclear data libraries; data acquisition from multichannel analyser; spectrum display with automatic area and FWHM determinations. This software is to be applied in analytical process control where time response is a very important parameter. PAGE takes ca. 1.5 minutes to analyse a complex spectrum from a 4096 channels MCA. (author)

  19. Support vector machines for prediction and analysis of beta and gamma-turns in proteins.

    Science.gov (United States)

    Pham, Tho Hoan; Satou, Kenji; Ho, Tu Bao

    2005-04-01

    Tight turns have long been recognized as one of the three important features of proteins, together with alpha-helix and beta-sheet. Tight turns play an important role in globular proteins from both the structural and functional points of view. More than 90% tight turns are beta-turns and most of the rest are gamma-turns. Analysis and prediction of beta-turns and gamma-turns is very useful for design of new molecules such as drugs, pesticides, and antigens. In this paper we investigated two aspects of applying support vector machine (SVM), a promising machine learning method for bioinformatics, to prediction and analysis of beta-turns and gamma-turns. First, we developed two SVM-based methods, called BTSVM and GTSVM, which predict beta-turns and gamma-turns in a protein from its sequence. When compared with other methods, BTSVM has a superior performance and GTSVM is competitive. Second, we used SVMs with a linear kernel to estimate the support of amino acids for the formation of beta-turns and gamma-turns depending on their position in a protein. Our analysis results are more comprehensive and easier to use than the previous results in designing turns in proteins.

  20. A simple scintigraphic method for continuous monitoring of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Lipp, R.W.; Hammer, H.F.; Schnedl, W.; Dobnig, H.; Passath, A.; Leb, G.; Krejs, G.J. (Graz Univ. (Austria). Div. of Nuclear Medicine and Endocrinology)

    1993-03-01

    A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20-50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s anteroposterior exposures in the supine position are obtained for 90 min. A second recording sequence of 20 min is added after a 30-min interval. The results can be displayed as immediate cine-replay, as time-activity diagrams and/or as acitivty retention values. Complicated mathematical fittings are not necessary. The method lends itself equally to the testing of in- and outpatients. (orig.).

  1. /sup 99m/Tc-aminohexylidendiphosphonate and /sup 99/mTc-Pyrophosphate in the scintigraphic diagnosis of experimental cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Kafka, P; Mazurova, Y; Hadas, L; Vizda, J; Palicka, V; Grossman, V

    1987-10-01

    Experimental cardiomyopathy was provoked in 24 dogs with high intravenous doses of adrenaline and theophylline. These lesions were studied by means of the new agent /sup 99m/Tc-AHDP and /sup 99m/Tc-PYP in comparison. Cardiomyopathy could be imaged as early as 4 h after the onset of involvement but not later than 7 days. A maximum accumulation occurred in lesions 24 h old, /sup 99m/Tc uptake in the myocardium was graded scintigraphically, /sup 99m/Tc-AHDP was accumulated in the altered myocardium to a greater extent than /sup 99m/Tc-PYP. Scintigraphic findings were in good agreement with plasma levels of creatine-kinase. A comparison with histology demonstrated that the maximum accumulation of radiopharmaceuticals occurred at the time when the development of myocardium involvement reached the stage of myocytolysis.

  2. Prompt gamma-ray analysis of chlorine in superpozz cement concrete

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A., E-mail: aanaqvi@kfupm.edu.sa [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Kalakada, Zameer [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Al-Matouq, Faris A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Maslehuddin, M. [Center for Engineering Research, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Ur-Rehman, Khateeb [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2012-11-21

    The chlorine concentration in Superpozz (SPZ) cement concrete was analyzed using a newly designed prompt gamma-ray neutron activation (PGNAA) setup utilizing a portable neutron generator. The setup, which mainly consists of a neutron source along with its moderator placed side by side with a shielded gamma-ray detector, allows determining chloride concentration in a concrete structure from one side. The setup has been tested through chlorine detection in chloride-contaminated Superpozz (SPZ) cement concrete specimens using 6.11 and 2.86{+-}3.10 MeV chlorine prompt gamma-rays. The optimum 0.032{+-}0.012 wt% value of Minimum Detectable Concentration (MDC) of chlorine in SPZ cement concrete measured in this study shows a successful application of a portable neutron generator in chloride analysis of concrete structure for corrosion studies.

  3. Q{sub {gamma}-H2AX}, an analysis method for partial-body radiation exposure using {gamma}-H2AX in non-human primate lymphocytes

    Energy Technology Data Exchange (ETDEWEB)

    Redon, Christophe E., E-mail: redonc@mail.nih.gov [NIH, NCI, CCR, Laboratory of Molecular Pharmacology, Bethesda, MD 20892 (United States); Nakamura, Asako J.; Gouliaeva, Ksenia [NIH, NCI, CCR, Laboratory of Molecular Pharmacology, Bethesda, MD 20892 (United States); Rahman, Arifur; Blakely, William F. [Armed Forces Radiobiology Research Institute, Uniformed Services University, Bethesda, MD 20889-5603 (United States); Bonner, William M. [NIH, NCI, CCR, Laboratory of Molecular Pharmacology, Bethesda, MD 20892 (United States)

    2011-09-15

    We previously used the {gamma}-H2AX assay as a biodosimeter for total-body irradiation (TBI) exposure ({gamma}-rays) in a rhesus macaque (Macaca mulatta) model. Utilizing peripheral blood lymphocytes and plucked hairs, we obtained statistically significant {gamma}-H2AX responses days after total-body exposure to 1-8.5 Gy ({sup 60}Co {gamma}-rays at 55 cGy min{sup -1}). Here, we introduce a partial-body exposure analysis method, Q{sub {gamma}-H2AX}, which is based on the number of {gamma}-H2AX foci per damaged cells as evident by having one or more {gamma}-H2AX foci per cell. Results from the rhesus monkey - TBI study were used to establish Q{sub {gamma}-H2AX} dose-response calibration curves to assess acute partial-body exposures. {gamma}-H2AX foci were detected in plucked hairs for several days after in vivo irradiation demonstrating this assay's utility for dose assessment in various body regions. The quantitation of {gamma}-H2AX may provide a robust biodosimeter for analyzing partial-body exposures to ionizing radiation in humans.

  4. Analysis of burnt nuclear fuel elements by gamma-spectrometry

    International Nuclear Information System (INIS)

    Lammer, M.

    1978-01-01

    Gamma-spectrometry allows a non-destructive determination of the fission and activation product content of spent nuclear fuel. The concentration of some of these products depends significantly on the so-called fuel parameters which describe the irradiation history and the fuel composition. The use of these dependences for deriving ''unknown fuel parameters'' from measured fission product activities is investigated in this work. Relevant application fields are burnup determination, fuel testing and inspections within the nuclear materials safeguards programme. The present thesis investigates how these dependences can be used to derive unknown fuel parameters. The possibilities and basic limitations of deriving information from a measured gamma spectrum are considered on principle. The main conclusion is that only ratios of fission product activities allow the development of an interpretation method which is generally applicable to all types of fuel from different reactors. The dependence of activity ratios on cooling time, irradiation time, integrated and final neutron flux, fuel composition, as well as fission and breeding rates are then investigated and presented graphically in a way suitable for applicaton. These relationships can be used for the analysis of spent fuel, and the detailed procedures, which depend on the applicaton field, are worked out in this work. In order to test the interpretation methods, samples of nuclear fuel have been irradiated and the gamma spectra analysed. The methods developed in this work can be applied successfully to the analysis of burnt fuel in the frame of fuel testing programmes and to safeguards verification purposes. If however, apart from a gamma spectrum, no information on the investigated fuel is available, the above-mentioned parameters can be derived with low accuracy only. (author)

  5. Analysis of copper-nickel ores by gamma-gamma method in ore enrichment works

    International Nuclear Information System (INIS)

    Bol'shakov, A.Yu.; Tovstenko, Yu.G.; Chinskij, E.B.; Eliseev, G.I.

    1973-01-01

    The paper presents experimental data on continuous gamma-gamma assay of copper-nickel ores on conveyor belts and of dry discrete samples of classifier overflow at the enrichment plants of the Pechenganikel' group. The relative errors are given of the results of comparison of two-hour rapid analyses and shift and 24-hour chemical analyses of classifier overflow samples with the figures for gamma-gamma assay. The factors affecting the accuracy of the latter technique are elucidated. Practical recommendations are given on the use of this technique at the above enrichment plants. (author)

  6. Scintigraphic hepatobiliary function studies in newborn infants to diagnose biliary hypoplasia or atresia

    International Nuclear Information System (INIS)

    Askari-Sabi, Z.

    1987-01-01

    The results obtained from scintigraphic hepatobiliary function studies, intraoperative cholangiography and histological examinations in a total of 17 infants suspected of having biliary atresia were compared and analysed with reference to the clinical signs and symptoms observed. In most cases, the individual diagnostic procedures led to consistent findings, even though there were some variations in the clinical picture. Patient outcome is largely determined by the site of atresia, due to which fact surgical correction should be carried out as soon as possible, in any case before the 8th week post partum. (TRV) [de

  7. The theoretical study of full spectrum analysis method for airborne gamma-ray spectrometric data

    International Nuclear Information System (INIS)

    Ni Weichong

    2011-01-01

    Spectra of airborne gamma-ray spectrometry was found to be the synthesis of spectral components of radioelement sources by analyzing the constitution of radioactive sources for airborne gamma-ray spectrometric survey and establishing the models of gamma-ray measurement. The mathematical equation for analysising airborne gamma-ray full spectrometric data can be expressed into matrix and related expansions were developed for the mineral resources exploration, environmental radiation measurement, nuclear emergency monitoring, and so on. Theoretical study showed that the atmospheric radon could be directly computed by airborne gamma-ray spectrometric data with full spectrum analysis without the use of the accessional upward-looking detectors. (authors)

  8. Librarian driven analysis of gamma ray spectra

    International Nuclear Information System (INIS)

    Kondrashov, V.; Petersone, I.

    2002-01-01

    For a set of a priori given radionuclides extracted from a general nuclide data library, the authors use median estimates of the gamma-peak areas and estimates of their errors to produce a list of possible radionuclides matching gamma ray line(s). The identification of a given radionuclide is obtained by searching for a match with the energy information of a database. This procedure is performed in an interactive graphic mode by markers that superimpose, on the spectral data, the energy information and yields provided by a general gamma ray data library. This library of experimental data includes approximately 17,000 gamma ray energy lines related to 756 known gamma emitter radionuclides listed by the ICRP. (author)

  9. Component Analysis of Long-Lag, Wide-Pulse Gamma-Ray Burst ...

    Indian Academy of Sciences (India)

    Principal Component Analysis of Long-Lag, Wide-Pulse Gamma-Ray. Burst Data. Zhao-Yang Peng. ∗. & Wen-Shuai Liu. Department of Physics, Yunnan Normal University, Kunming 650500, China. ∗ e-mail: pzy@ynao.ac.cn. Abstract. We have carried out a Principal Component Analysis (PCA) of the temporal and spectral ...

  10. Computer programs for data reduction and interpretation in plutonium and uranium analysis by gamma ray spectrometry

    International Nuclear Information System (INIS)

    Singh, R.K.; Moorthy, A.D.; Babbar, R.K.; Udagatti, S.V.

    1989-01-01

    Non destructive gamma ray have been developed for analysis of isotopic abundances and concentrations of plutonium and uranium in the respective product solutions of a reprocessing plant. The method involves analysis of gamma rays emitted from the sample and uses a multichannel analyser system. Data reduction and interpretation of these techniques are tedious and time consuming. In order to make it possible to use them in routine analysis, computer programs have been developed in HP-BASIC language which can be used in HP-9845B desktop computer. A set of programs, for plutonium estimation by high resolution gamma ray spectrometry and for on-line measurement of uranium by gamma ray spectrometry are described in this report. (author) 4 refs., 3 tabs., 6 figs

  11. Gamma camera image processing and graphical analysis mutual software system

    International Nuclear Information System (INIS)

    Wang Zhiqian; Chen Yongming; Ding Ailian; Ling Zhiye; Jin Yongjie

    1992-01-01

    GCCS gamma camera image processing and graphical analysis system is a special mutual software system. It is mainly used to analyse various patient data acquired from gamma camera. This system is used on IBM PC, PC/XT or PC/AT. It consists of several parts: system management, data management, device management, program package and user programs. The system provides two kinds of user interfaces: command menu and command characters. It is easy to change and enlarge this system because it is best modularized. The user programs include almost all the clinical protocols used now

  12. A gamma scintigraphic study of gastric coating by Expidet, tablet and liquid formulations

    International Nuclear Information System (INIS)

    Washington, N.; Wilson, C.G.; Greaves, J.L.; Norman, S.

    1989-01-01

    The gastric residence time and gastric coating properties of 10 mg of radiolabelled micronised resin incorporated into Expidet formulations, chewable tablets and 10 ml of a liquid formulation were measued by gamma scintigraphy in twelve fasted, healthy subjects. All preparations emptied from the stomach in a similar manner for the first 1.5 h; however, the final 10% of the activity from the Expidet formulation emptied considerably more slowly than the initial phase. The total mean gastric emptying times for the three formulations were 2.3, 2.5 and 5.5 h for the tablet, liquid and Expidet formulation, respectively. The amount of activity following administration of the table or Expidet formulation was the same in the three regions of the stomach, but the coating of the mucosa by the Expidet formulation within each area was observed to be more uniform due to the greater dispersion of the dose form. The table broke up into a number of small discrete pieces. The gastric residence time of 99m Tc-labelled resin delivered in an Expidet formulation is significantly longer than the same marker administered in a table or in 10 ml of a liquid formulation. Moreover, coating of the gastric mucosa was more uniform with the Expidet formulation than the other two formulations studied. (author) 10 refs.; 6 figs

  13. SU-E-T-647: Quality Assurance of VMAT by Gamma Analysis Dependence On Low-Dose Threshold

    International Nuclear Information System (INIS)

    Song, J; Kim, M; Lee, S; Lee, M; Suh, T; Park, S

    2015-01-01

    Purpose: The AAPM TG-119 instructed institutions to use low-dose threshold (LDT) of 10% or a ROI determined by the jaw when they collected gamma analysis QA data of planar dose distribution. Also, based on a survey by Nelms and Simon, more than 70% of institutions use a LDT between 0% and 10% for gamma analysis. However, there are no clinical data to quantitatively demonstrate the impact of the LDT on the gamma index. Therefore, we performed a gamma analysis with LDTs of 0% to 15% according to both global and local normalization and different acceptance criteria: 3%/3 mm, 2%/2 mm, and 1%/1 mm. Methods: A total of 30 treatment plans—10 head and neck, 10 brain, and 10 prostate cancer cases—were randomly selected from the Varian Eclipse TPS, retrospectively. For the gamma analysis, a predicted portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using a Varian Clinac iX and an EPID. Then, the gamma analysis was performed using the Portal Dosimetry software. Results: For the global normalization, the gamma passing rate (%GP) decreased as the LDT increased, and all cases of low-dose thresholds exhibited a %GP above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for local normalization, the %GP increased as LDT increased. The gamma passing rate with LDT of 10% increased by 6.86%, 9.22% and 6.14% compared with the 0% in the case of the head and neck, brain and prostate for 3%/3 mm criteria, respectively. Conclusion: Applying the LDT in the global normalization does not have critical impact to judge patient-specific QA results. However, LDT for the local normalization should be carefully selected because applying the LDT could affect the average of the %GP to increase rapidly

  14. SU-E-T-647: Quality Assurance of VMAT by Gamma Analysis Dependence On Low-Dose Threshold

    Energy Technology Data Exchange (ETDEWEB)

    Song, J; Kim, M; Lee, S; Lee, M; Suh, T [Department of Biomedical Engineering, Reasearch Institute of Biomedical Engineering, The Catholic University of Korea, Seoul (Korea, Republic of); Park, S [Department of Biomedical Engineering, Reasearch Institute of Biomedical Engineering, The Catholic University of Korea, Seoul (Korea, Republic of); Department of Radiation Oncology, Uijeongbu St. Mary’s Hospital, Gyeonggi-do (Korea, Republic of)

    2015-06-15

    Purpose: The AAPM TG-119 instructed institutions to use low-dose threshold (LDT) of 10% or a ROI determined by the jaw when they collected gamma analysis QA data of planar dose distribution. Also, based on a survey by Nelms and Simon, more than 70% of institutions use a LDT between 0% and 10% for gamma analysis. However, there are no clinical data to quantitatively demonstrate the impact of the LDT on the gamma index. Therefore, we performed a gamma analysis with LDTs of 0% to 15% according to both global and local normalization and different acceptance criteria: 3%/3 mm, 2%/2 mm, and 1%/1 mm. Methods: A total of 30 treatment plans—10 head and neck, 10 brain, and 10 prostate cancer cases—were randomly selected from the Varian Eclipse TPS, retrospectively. For the gamma analysis, a predicted portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using a Varian Clinac iX and an EPID. Then, the gamma analysis was performed using the Portal Dosimetry software. Results: For the global normalization, the gamma passing rate (%GP) decreased as the LDT increased, and all cases of low-dose thresholds exhibited a %GP above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for local normalization, the %GP increased as LDT increased. The gamma passing rate with LDT of 10% increased by 6.86%, 9.22% and 6.14% compared with the 0% in the case of the head and neck, brain and prostate for 3%/3 mm criteria, respectively. Conclusion: Applying the LDT in the global normalization does not have critical impact to judge patient-specific QA results. However, LDT for the local normalization should be carefully selected because applying the LDT could affect the average of the %GP to increase rapidly.

  15. Gamma spectrum analysis including NAA with SAMPO for Windows

    International Nuclear Information System (INIS)

    Aarnio, P.A.; Nikkinen, M.T.; Routti, J.T.

    1995-01-01

    SAMPO for Windows is a high performance gamma spectrum analysis program. All the measurement, analysis and NAA phases can be done either under full interactive use control or user defined tasks can be used for automated measurement and analysis sequences including control of MCAs and sample changers. High resolution gamma-ray spectroscopy together with the possibility to resolve complex multiplets with high accuracy makes SAMPO very suitable for INAA. On the other hand, the possibility to automate analysis sequences allows it use effectively also in all routine NAA measurements. NAA in SAMPO is accomplished using comparative methods. Spectra of standards, flux monitors, controls and actual samples are analyzed normally to obtain the peak areas which are optionally corrected for decay. In the comparison the flux monitor results are used to correct for variations in the effective neutron flux. An optional irradiation position correction can also be applied. The controls are used to alarm for possible deviations in the results. The sophisticated spectrum analysis methods used together with the comparative NAA and monitors give accurate results limited by the systematic effects only. The Windows environment provides ease of use and further processing power is available through the interface to expert system identification of nuclides. (author) 19 refs.; 1 tab

  16. Scintigraphic visualization of bacterial translocation in experimental strangulated intestinal obstruction

    International Nuclear Information System (INIS)

    Galeev, Yu.M.; Popov, M.V.; Salato, O.V.; Lishmanov, Yu.B.; Grigorev, E.G.; Aparcin, K.A.

    2009-01-01

    The purpose of this study was to obtain scintigraphic images depicting translocation of 99m Tc-labelled Escherichia coli bacteria through the intestinal barrier and to quantify this process using methods of nuclear medicine. Thirty male Wistar rats (including 20 rats with modelled strangulated intestinal obstruction and 10 healthy rats) were used for bacterial scintigraphy. 99m Tc-labelled E. coli bacteria ( 99m Ts-E. coli) with an activity of 7.4-11.1 MBq were administered into a section of the small intestine. Scintigraphic visualization of bacterial translocation into organs and tissues of laboratory animals was recorded in dynamic (240 min) and static (15 min) modes. The number of labelled bacteria, which migrated through the intestinal barrier, was quantified by calculating the translocation index (TI). Control indicated no translocation of 99m Ts-E. coli administered into the intestine through the parietes of the small intestine's distal part in healthy animals. Animals with strangulated obstruction demonstrated different migration strength and routes of labelled bacteria from strangulated and superior to strangulation sections of the small intestine. 99m Ts-E. coli migrated from the strangulated loop into the peritoneal cavity later causing systemic bacteraemia through peritoneal resorption. The section of the small intestine, which was superior to the strangulation, demonstrated migration of labelled bacteria first into the portal and then into the systemic circulation. The strangulated section of the small intestine was the main source of bacteria dissemination since the number of labelled bacteria, which migrated from this section significantly, exceeded that of the area superior to the strangulation section of the small intestine (p = 0.0003). Bacterial scintigraphy demonstrated the possibility of visualizing migration routes of labelled bacteria and quantifying their translocation through the intestinal barrier. This approach to study bacterial

  17. Upgrading of analogue gamma cameras with PC based computer system

    International Nuclear Information System (INIS)

    Fidler, V.; Prepadnik, M.

    2002-01-01

    Full text: Dedicated nuclear medicine computers for acquisition and processing of images from analogue gamma cameras in developing countries are in many cases faulty and technologically obsolete. The aim of the upgrading project of International Atomic Energy Agency (IAEA) was to support the development of the PC based computer system which would cost 5.000 $ in total. Several research institutions from different countries (China, Cuba, India and Slovenia) were financially supported in this development. The basic demands for the system were: one acquisition card an ISA bus, image resolution up to 256x256, SVGA graphics, low count loss at high count rates, standard acquisition and clinical protocols incorporated in PIP (Portable Image Processing), on-line energy and uniformity correction, graphic printing and networking. The most functionally stable acquisition system tested on several international workshops and university clinics was the Slovenian one with a complete set of acquisition and clinical protocols, transfer of scintigraphic data from acquisition card to PC through PORT, count loss less than 1 % at count rate of 120 kc/s, improvement of integral uniformity index by a factor of 3-5 times, reporting, networking and archiving solutions for simple MS network or server oriented network systems (NT server, etc). More than 300 gamma cameras in 52 countries were digitized and put in the routine work. The project of upgrading the analogue gamma cameras yielded a high promotion of nuclear medicine in the developing countries by replacing the old computer systems, improving the technological knowledge of end users on workshops and training courses and lowering the maintenance cost of the departments. (author)

  18. Gamma Activation Analysis in the Havana Bay superficial sediments

    International Nuclear Information System (INIS)

    Lopez, N.; Gelen, A.; Diaz Riso, O.; Manso, M.V.; Simon, M.J.; Maslov, A.G.; Gustova, M.V.; Beltran, J.; Soto, J.

    2003-01-01

    A preliminary study of 26 elements of Havana Bay superficial sediments were made using Gamma Activation Analysis. Samples from five zones of Havana Bay were analyzed. The results show a close interrelation between the concentration levels of the studied elements and the contaminant sources

  19. A compact neutron beam generator system designed for prompt gamma nuclear activation analysis.

    Science.gov (United States)

    Ghassoun, J; Mostacci, D

    2011-08-01

    In this work a compact system was designed for bulk sample analysis using the technique of PGNAA. The system consists of (252)Cf fission neutron source, a moderator/reflector/filter assembly, and a suitable enclosure to delimit the resulting neutron beam. The moderator/reflector/filter arrangement has been optimised to maximise the thermal neutron component useful for samples analysis with a suitably low level of beam contamination. The neutron beam delivered by this compact system is used to irradiate the sample and the prompt gamma rays produced by neutron reactions within the sample elements are detected by appropriate gamma rays detector. Neutron and gamma rays transport calculations have been performed using the Monte Carlo N-Particle transport code (MCNP5). 2010 Elsevier Ltd. All rights reserved.

  20. Failure modes and effects analysis (FMEA) for Gamma Knife radiosurgery.

    Science.gov (United States)

    Xu, Andy Yuanguang; Bhatnagar, Jagdish; Bednarz, Greg; Flickinger, John; Arai, Yoshio; Vacsulka, Jonet; Feng, Wenzheng; Monaco, Edward; Niranjan, Ajay; Lunsford, L Dade; Huq, M Saiful

    2017-11-01

    Gamma Knife radiosurgery is a highly precise and accurate treatment technique for treating brain diseases with low risk of serious error that nevertheless could potentially be reduced. We applied the AAPM Task Group 100 recommended failure modes and effects analysis (FMEA) tool to develop a risk-based quality management program for Gamma Knife radiosurgery. A team consisting of medical physicists, radiation oncologists, neurosurgeons, radiation safety officers, nurses, operating room technologists, and schedulers at our institution and an external physicist expert on Gamma Knife was formed for the FMEA study. A process tree and a failure mode table were created for the Gamma Knife radiosurgery procedures using the Leksell Gamma Knife Perfexion and 4C units. Three scores for the probability of occurrence (O), the severity (S), and the probability of no detection for failure mode (D) were assigned to each failure mode by 8 professionals on a scale from 1 to 10. An overall risk priority number (RPN) for each failure mode was then calculated from the averaged O, S, and D scores. The coefficient of variation for each O, S, or D score was also calculated. The failure modes identified were prioritized in terms of both the RPN scores and the severity scores. The established process tree for Gamma Knife radiosurgery consists of 10 subprocesses and 53 steps, including a subprocess for frame placement and 11 steps that are directly related to the frame-based nature of the Gamma Knife radiosurgery. Out of the 86 failure modes identified, 40 Gamma Knife specific failure modes were caused by the potential for inappropriate use of the radiosurgery head frame, the imaging fiducial boxes, the Gamma Knife helmets and plugs, the skull definition tools as well as other features of the GammaPlan treatment planning system. The other 46 failure modes are associated with the registration, imaging, image transfer, contouring processes that are common for all external beam radiation therapy

  1. Somatostatin receptor scintigraphy and intraoperative gamma probe detection in the localisation and treatment of pancreatic insulinoma

    International Nuclear Information System (INIS)

    Loh, Nelson K.; Macdonald, William B.; Dunne, Marina L.; Rao, Sudhakar

    2009-01-01

    Full text: Aims: We report a case of insulinoma that was successfully enucleated under radio-guidance after an initial unsuccessful laparotomy. This case highlights the utility of Somatostatin Receptor Scintigraphy (SRS) and gamma probe in the localisation and treatment of neuroendocrine tumours. Methods: The patient presented with recurrent hypoglycaemia. An abdominal CT scan identified a lesion in the uncinate process of the pancreas, however, laparotomy with use of intraoperative ultrasound failed to localise the lesion. SRS with SPECTICT was then requested by the surgical team with a view to radio-guided surgery. Results: SRS demonstrated an octreotide-avid tumour in the posterior uncinate process of the pancreas, and confirmed suitability for radio-guided surgery. At re-exploration, the surgeon was again unable to palpate the lesion or localise it with intraoperative ultrasound, however, the lesion was successfully detected and removed with the use of a gamma probe. A postoperative SRS confirmed complete excision and histopathology was diagnostic of insulinoma. Conclusion: This case highlights the utility of SRS in the intraoperative localisation and surgical excision of neuroendocrine tumours. The lesion was unable to be localised clinically or with intraoperative ultrasound but was successfully detected with scintigraphic techniques. The surgical team acknowledge that the use of a gamma probe enabled enucleation of the insulinoma, which obviated the need for an invasive Whipple's procedure.

  2. Monitoring and Analysis of Environmental Gamma Dose Rate around Serpong Nuclear Complex

    Directory of Open Access Journals (Sweden)

    I.P. Susila

    2017-08-01

    Full Text Available An environmental radiation monitoring system that continuously measures gamma dose rate around nuclear facilities is an important tool to present dose rate information to the public or authorities for radiological protection during both normal operation and radiological accidents. We have developed such a system that consists of six GM-based device for monitoring the environmental dose rate around Serpong Nuclear Complex. It has operated since 2010. In this study, a description of the system and analysis of measured data are presented. Analysis of the data for the last five years shows that the average dose rate levels were between 84-99 nSv/h which are still lower than terrestrial gamma radiation levels at several other locations in Indonesia. Time series analysis of the monitoring data demonstrates a good agreement between an increase in environmental gamma dose rate and the presence of iodine and argon in the air by in situ measurement. This result indicates that system is also effective for an early warning system in the case of radiological emergency.

  3. Scintigraphic evaluation of the osteoblastic activity of rabbit tibial defects after HYAFF11 membrane application.

    Science.gov (United States)

    Mermerkaya, Musa Uğur; Doral, Mahmut Nedim; Karaaslan, Fatih; Huri, Gazi; Karacavuş, Seyhan; Kaymaz, Burak; Alkan, Erkan

    2016-05-03

    An unfavorable condition for bone healing is the presence of bone defects. Under such conditions, a material can play a role to cover fractured or defective bone. Technological advances now allow for the use of such material. Hyalonect(®) (Fidia Advanced Biopolymers SLR, Italy), a novel membrane comprising knitted fibers of esterified hyaluronan (HYAFF11) can be used to cover fractured or grafted bone and can also serve as a scaffold to keep osteoprogenitor cells in place. The aim of this study was to compare osteoblastic activity by the use of scintigraphic methods in defective rabbit tibias during early-phase bone healing with or without a hyaluronan-based mesh. Two groups (A and B) of New Zealand albino rabbits were used; each group included 10 animals. Operations on all rabbits were performed under general anesthesia. We also resected 10-mm bone segments from each animal's tibial diaphysis. After resection, tibias with defects were fixed using Kirschner wires. In group A, no hyaluronan-based mesh was used. In group B, tibial segmental defects were enclosed with a hyaluronan-based mesh. The rabbits were followed up for 4 weeks postoperatively, after which bone scintigraphic studies were performed on each animal to detect and compare osteoblastic activity. The mean count in the fracture side of the hyaluronan-based mesh group was significantly higher compared to that of the group A (p = 0.019). However, there was no significant difference between group B and control rabbits with respect to the mean count on the intact bone side (p = 0.437). The bone defect (fracture)/intact bone mean count ratio was significantly higher in group B compared to group A (p = 0.008). A hyaluronan-based mesh plays a role in promoting osteoblastic activity. Hyalonect(®) is suitable for restoring tissue continuity whenever the periosteal membrane is structurally impaired or inadequate. Our results demonstrated that, during early-phase bone healing, osteoblastic activity

  4. Computer code for qualitative analysis of gamma-ray spectra

    International Nuclear Information System (INIS)

    Yule, H.P.

    1979-01-01

    Computer code QLN1 provides complete analysis of gamma-ray spectra observed with Ge(Li) detectors and is used at both the National Bureau of Standards and the Environmental Protection Agency. It locates peaks, resolves multiplets, identifies component radioisotopes, and computes quantitative results. The qualitative-analysis (or component identification) algorithms feature thorough, self-correcting steps which provide accurate isotope identification in spite of errors in peak centroids, energy calibration, and other typical problems. The qualitative-analysis algorithm is described in this paper

  5. Cold neutron prompt gamma activation analysis at NIST; A progress report

    Energy Technology Data Exchange (ETDEWEB)

    Paul, R L; Lindstrom, R M [National Inst. of Standards and Technology, Gaithersburg, MD (United States). Div. of Inorganic Analytical Research; Vincent, D H [Michigan Univ., Ann Arbor, MI (United States). Dept. of Nuclear Engineering

    1994-05-01

    An instrument for prompt gamma-ray activation analysis is now in operation at the NIST Cold Neutron Research Facility (CNRF). The cold neutron beam is relatively free of contamination by fast neutrons and reactor gamma rays, and the neutron fluence rate is 1.5 x 10 [sup 8] cm [sup -2] x s [sup -1] (thermal equivalent). As a result of a compact target-detector geometry the sensitivity is better by a factor of as much as seven than that obtained with an existing thermal instrument, and hydrogen background is a factor of 50 lower. This instrument was applied to multielement analysis of the Allende meteorite and other materials. (author) 14 refs.; 2 figs.; 1 tab.

  6. Temporal contrast enhancement and parametric imaging for the visualisation of time patterns in dynamic scintigraphic imaging

    International Nuclear Information System (INIS)

    Deconinck, F.; Bossuyt, A.; Lepoudre, R.

    1982-01-01

    Image contrast, photon noise and sampling frequency limit the visual extraction of relevant temporal information in scintigraphic image series. When the Unitation is mainly due to low temporal contrast, temporal contrast enhancement will strongly improve the perceptibility of time patterns in the series. When the limitation is due to photon noise and limited temporal sampling, parametric imaging by means of the Hadamard transform can visualise temporal patterns. (WU)

  7. Scintigraphic appearance of stress-induced trauma of the dorsal cortex of the third metacarpal bone in racing Thoroughbred horses: 121 cases (1978-1986)

    International Nuclear Information System (INIS)

    Koblik, P.D.; Hornof, W.J.; Seeherman, H.J.

    1988-01-01

    Review of 121 bone scintigrams obtained on racing Thoroughbred horses with clinical histories indicative of forelimb lameness revealed 3 scintigraphic patterns of stress-induced trauma to the dorsal cortex of the third metacarpal bone: (1) focal, intense uptake associated with recent stress fracture; (2) regional uptake of varying intensity or a mixed pattern of uptake associated with chronic stress fracture; and (3) diffuse, mild to moderate uptake associated with periostitis (bucked shins). The latter scintigraphic pattern appeared to be an exaggerated manifestation of the normal remodeling process evident in immature horses (2 to 3 years old). Scintigraphy was most helpful in identifying radiographically occult stress fractures, determining the extent of cortical involvement before surgical intervention in cases of chronic stress fractures, and monitoring the fracture healing process

  8. The first results of measurements in military hospital laboratory for gamma spectrometry analysis

    International Nuclear Information System (INIS)

    Jankovic, Lj.; Pantelic, G.; Misovic, M.

    1997-01-01

    In this paper we present the basic features of the equipment for gamma spectrometry analysis and the first measurements results of the 134 Cs and 137 Cs activities. Gamma spectrum is measured using HP GE Detector. The obtained results show low level activities of the 134 Cs and 137 Cs in the environment. (author)

  9. Analysis of the gamma spectra of the uranium, actinium, and thorium decay series

    International Nuclear Information System (INIS)

    Momeni, M.H.

    1981-09-01

    This report describes the identification of radionuclides in the uranium, actinium, and thorium series by analysis of gamma spectra in the energy range of 40 to 1400 keV. Energies and absolute efficiencies for each gamma line were measured by means of a high-resolution germanium detector and compared with those in the literature. A gamma spectroscopy method, which utilizes an on-line computer for deconvolution of spectra, search and identification of each line, and estimation of activity for each radionuclide, was used to analyze soil and uranium tailings, and ore

  10. Scintigraphic evaluation of traumatic splenic lesions in children

    International Nuclear Information System (INIS)

    Erasmie, U.; Mortensson, W.; Persson, U.; Laennergren, K.; St. Goerans Children's Hospital, Stockholm

    1988-01-01

    Ninety-eight children with recent blunt abdominal trauma which initially evoked clinical suspicion of splenic injury were examined with colloid scintigraphy of the spleen and the liver using multiple imaging views and with abdominal survey. Nineteen children were, in addition, examined with tomographic scintigraphy. The clinical findings and the course of the disorder were reanalysed. Scintigraphy indicated splenic injury in 56 children and hepatic injury in another 5 children. The left lateral and the left oblique were the optimum imaging views for detecting splenic ruptures. Tomographic scintigraphy did not improve the diagnostic yield. Abdominal survey failed to indicate almost every second case of splenic rupture and provided no additional information of significance. The clinical review agreed with the scintigraphic diagnosis of splenic lesions but, in addition, it suggested possible splenic lesions in another 10 children with normal scintigraphy. This discrepancy cannot be explained as surgery was not employed; the occurrence of splenic lesions too small to become detectable at scintigraphy or to provoke clinically evident symptoms may be supposed. (orig.)

  11. Right ventricular function: methodologic and clinical considerations in noninvasive scintigraphic assessment

    International Nuclear Information System (INIS)

    Manno, B.V.; Iskandrian, A.S.; Hakki, A.H.

    1984-01-01

    Right ventricular function plays an important role in many cardiac disorders. Changes in left ventricular function, right ventricular afterload and preload, cardiac medications and ischemia may affect right ventricular function. Radionuclide ventriculography permits quantitative assessment of regional and global function of the right ventricle. This assessment can be made at rest, during exercise or after pharmacologic interventions. The overlap between right ventricle and right atrium is a major limitation for gated scintigraphic techniques. The use of imaging with newer short-lived radionuclides may permit more accurate and reproducible assessment of right ventricular function by means of the first pass method. Further work in areas related to improvement of techniques and the impact of right ventricular function on prognosis is needed

  12. Standard gamma-ray spectra for the comparison of spectral analysis software

    Energy Technology Data Exchange (ETDEWEB)

    Woods, S.; Hemingway, J.; Bowles, N. [and others

    1997-08-01

    Three sets of standard {gamma}-ray spectra have been produced for use in assessing the performance of spectral analysis software. The origin of and rationale behind the spectra are described. Nine representative analysis systems have been tested both in terms of component performance and in terms of overall performance and the problems encountered in the analysis are discussed. (author)

  13. Analysis of gamma spectra with a HP calcultor

    International Nuclear Information System (INIS)

    Rocc, H.C.

    1978-01-01

    Three programs for the analysis of gamma spectra, specially useful for neutron activation analysis, were adapted and tested. The equipment used is a Hewlett-Packard, model 9810-A desk-computer, supplied with punched tape reader, additional memory in magnetic tape and plotter, being the system capacity 111 numerical registers and 2036 programme steps. The first programme allows automatic photopeak detection in spectra up to 4096 channels, obtained with Ge(Li) detectors,generating the corresponding background radiation line. The areas and their standard deviations are calculated and the spectrum and background can be plotted [pt

  14. Increased technetium uptake is not equivalent to muscle necrosis: scintigraphic, morphological and intramuscular pressure analyses of sore muscles after exercise

    Science.gov (United States)

    Crenshaw, A. G.; Friden, J.; Hargens, A. R.; Lang, G. H.; Thornell, L. E.

    1993-01-01

    A scintigraphic technique employing technetium pyrophosphate uptake was used to identify the area of skeletal muscle damage in the lower leg of four runners 24 h after an ultramarathon footrace (160 km). Most of the race had been run downhill which incorporated an extensive amount of eccentric work. Soreness was diffuse throughout the posterior region of the lower leg. In order to interpret what increased technetium uptake reflects and to express extreme endurance related damages, a biopsy was taken from the 3-D position of abnormal uptake. In addition, intramuscular pressures were determined in the deep posterior compartment. Scintigraphs revealed increased technetium pyrophosphate uptake in the medial portion of the gastrocnemius muscle. For 3698 fibres analysed, 33 fibres (1%) were necrotic, while a few other fibres were either atrophic or irregular shaped. A cluster of necrotic fibres occurred at the fascicular periphery for one subject and fibre type grouping occurred for another. Ultrastructural analysis revealed Z-line streaming near many capillaries and variously altered subsarcolemmal mitochondria including some with paracrystalline inclusions. The majority of the capillaries included thickened and irregular shaped endothelial cells. Intramuscular pressures of the deep posterior compartment were slightly elevated (12-15 mmHg) for three of the four subjects. Increased technetium uptake following extreme endurance running does not just reflect muscle necrosis but also subtle fibre abnormalities. Collectively, these pathological findings are attributed to relative ischaemia occurring during the race and during pre-race training, whereas, intramuscular pressure elevations associated with muscle soreness are attributed to mechanical stress caused by extensive eccentric work during the race.

  15. Detection of rejection of canine orthotopic cardiac allografts with indium-111 lymphocytes and gamma scintigraphy

    International Nuclear Information System (INIS)

    Eisen, H.J.; Rosenbloom, M.; Laschinger, J.C.; Saffitz, J.E.; Cox, J.L.; Sobel, B.E.; Bolman, R.M. III; Bergmann, S.R.

    1988-01-01

    Previous studies have demonstrated the feasibility of detecting canine heterotopic cardiac allograft rejection scintigraphically after administration of 111In lymphocytes. To determine whether the approach is capable of detecting rejection in orthotopic cardiac transplants in which labeled lymphocytes circulating in the blood pool may reduce sensitivity, the present study was performed in which canine orthotopic cardiac transplants were evaluated in vivo. Immunosuppression was maintained with cyclosporine A (10-20 mg/kg/day) and prednisone (1 mg/kg/day) for 2 wk after transplantation. Subsequently, therapy was tapered. Five successful allografts were evaluated scintigraphically every 3 days after administration of 100-350 microCi 111In autologous lymphocytes. Correction for labeled lymphocytes circulating in the blood pool, but not actively sequestered in the allografts was accomplished by administering 3-6 mCi 99mTc autologous erythrocytes and employing a previously validated blood-pool activity correction technique. Cardiac infiltration of labeled lymphocytes was quantified as percent indium excess (%IE), scintigraphically detectable 111In in the transplant compared with that in blood, and results were compared with those of concomitantly performed endomyocardial biopsy. Scintigraphic %IE for hearts not undergoing rejection manifest histologically was 0.7 +/- 0.4. Percent IE for rejecting hearts was 6.8 +/- 4.0 (p less than 0.05). Scintigraphy detected each episode of rejection detected by biopsy. Scintigraphic criteria for rejection (%IE greater than 2 s.d. above normal) were not manifest in any study in which biopsies did not show rejection. Since scintigraphic results with 111In-labeled lymphocytes were concordant with biopsy results in orthotopic cardiac transplants, noninvasive detection of graft rejection in patients should be attainable with the approach developed

  16. Prototype of an expert system to help nuclide identification in gamma spectrum analysis

    International Nuclear Information System (INIS)

    Jayanthi, Kasi Annapurna; Corcuera, Raquel Paviotti; Oliveira, Gina Maira B.

    1995-01-01

    This report describes the development and use of IDENT, prototype of an expert system that helps the researcher to identify radionuclides in gamma-ray spectroscopy. Normally the method adopted by the researcher is iterative, time consuming and becomes complicated in the analysis of large and complex gamma-ray spectra. The present expert system is based on the knowledge transmitted by expert and specialists in this area and the results show that it is helpful for researches who perform nuclide identification through gamma-ray spectroscopy. The gamma-ray spectrum of a material sample with about 140 peaks would take about a week or two be analysed by a specialist. The same task can be done in a few minutes using this expert system. (author). 14 refs., 2 figs

  17. ROBOCAL: An automated NDA [nondestructive analysis] calorimetry and gamma isotopic system

    International Nuclear Information System (INIS)

    Hurd, J.R.; Powell, W.D.; Ostenak, C.A.

    1989-01-01

    ROBOCAL, which is presently being developed and tested at Los Alamos National Laboratory, is a full-scale, prototype robotic system for remote calorimetric and gamma-ray analysis of special nuclear materials. It integrates a fully automated, multidrawer, vertical stacker-retriever system for staging unmeasured nuclear materials, and a fully automated gantry robot for computer-based selection and transfer of nuclear materials to calorimetric and gamma-ray measurement stations. Since ROBOCAL is designed for minimal operator intervention, a completely programmed user interface is provided to interact with the automated mechanical and assay systems. The assay system is designed to completely integrate calorimetric and gamma-ray data acquisition and to perform state-of-the-art analyses on both homogeneous and heterogeneous distributions of nuclear materials in a wide variety of matrices

  18. Pasteurized intercalary autogenous bone graft: radiographic and scintigraphic features

    International Nuclear Information System (INIS)

    Ehara, Shigeru; Tamakawa, Yoshiharu; Nishida, Jun; Shiraishi, Hideo

    2000-01-01

    Objective. Pasteurized autogenous bone graft sterilized at a low temperature (60 C) is one option for reconstruction after resection of bone and soft tissue tumors. The purpose of this investigation was to assess the normal and abnormal radiographic and scintigraphic findings of pasteurized intercalary autogenous bone graft after resection of bone and soft tissue sarcomas.Design. This was a retrospective evaluation of the radiography and bone scintigraphy findings in patients after treatment of bone and soft tissue sarcomas using an intercalary pasteurized autogenous bone graft.Patients. Among 10 consecutive patients, eight had intercalary grafts, and they constitute the subjects of this study. All available radiography and bone scintigraphy findings were reviewed for the healing process and the possibility of complications.Results and conclusions. Healing and incorporation of the graft were observed in five patients during the follow-up, but the other three did not heal satisfactorily. Rapid incorporation of pasteurized autogenous bone graft can be demonstrated by means of radiography and bone scintigraphy. (orig.)

  19. GammaLog Playback 1.0 - mobile gamma ray spectrometry software

    International Nuclear Information System (INIS)

    Watson, R.J.; Smethurst, M.A.

    2011-01-01

    The Geological Survey of Norway (NGU) operates a mobile gamma ray spectrometer system which can be used in nuclear emergency situations to determine the location and type of orphan sources, or the extent and type of fallout contamination. The system consists of a 20 litre (16 litre downward and 4 litre upward looking) RSX-5 NaI detector and spectrometer, and can be mounted in fixed wing aircraft, helicopters, or vans/cars as appropriate. NGU has developed its own data acquisition and analysis software for this system. GammaLog (Smethurst 2005) controls the acquisition, display, and storage of data from the spectrometer, and performs real-time data analysis including estimation of dose rates and fallout concentrations, and separation of geological and anthropogenic components of the signal. The latter is particularly important where the geological radioisotope signal varies strongly from one place to another, and makes it easier to locate and identify anthropogenic sources which might otherwise be difficult to separate from the geological background signal. A modified version of GammaLog has been developed, GammaLog Playback, which allows the replay of previously acquired GammaLog datasets, while performing similar processing and display as the GammaLog acquisition software. This allows datasets to be reviewed and compared in the field or during post-survey analysis to help plan subsequent measurement strategies.(Au)

  20. Application of Principal Component Analysis in Prompt Gamma Spectra for Material Sorting

    Energy Technology Data Exchange (ETDEWEB)

    Im, Hee Jung; Lee, Yun Hee; Song, Byoung Chul; Park, Yong Joon; Kim, Won Ho

    2006-11-15

    For the detection of illicit materials in a very short time by comparing unknown samples' gamma spectra to pre-programmed material signatures, we at first, selected a method to reduce the noise of the obtained gamma spectra. After a noise reduction, a pattern recognition technique was applied to discriminate the illicit materials from the innocuous materials in the noise reduced data. Principal component analysis was applied for a noise reduction and pattern recognition in prompt gamma spectra. A computer program for the detection of illicit materials based on PCA method was developed in our lab and can be applied to the PGNAA system for the baggage checking at all ports of entry at a very short time.

  1. Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

    Science.gov (United States)

    Jeong, Meeyoung; Lee, Kyeong Beom; Kim, Kyeong Ja; Lee, Min-Kie; Han, Ju-Bong

    2014-12-01

    Odyssey, one of the NASA¡¯s Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of 40K, 232Th and 238U in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

  2. Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

    Directory of Open Access Journals (Sweden)

    Meeyoung Jeong

    2014-12-01

    Full Text Available Odyssey, one of the NASA’s Mars exploration program and SELENE (Kaguya, a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of 40K, 232Th and 238U in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

  3. The analysis of the gamma-ray pulseheight spectra resulting from the NaI detector

    International Nuclear Information System (INIS)

    Huang Zhengde; Zhang Guishan; Chen Qun; Cao Zhong

    1990-01-01

    The analysis of the Gamma-ray pulse-height spectra resulting from NaI detector is described by using weighted least square iteration. The computer program has the function of searching for Gamma-ray peak automatically. It can be used in the analysis of continuous, discrete or their superposition spectra. Besides, there are some function of the spectrum smooth,the correction of the shift in gain and zero energy channel intercept. Some results of the computer program are presented

  4. Technical Aspect for Operating Portable Prompt Gamma Neutron Activation Analysis (PGNAA) on Terengganu Inscribed Stone

    International Nuclear Information System (INIS)

    Rasif Mohd Zain; Hearie Hassan; Roslan Yahya

    2015-01-01

    Prompt Gamma Neutron Activation analysis (PGNAA) is a type of neutron activation analysis which can determined element with nearly no gamma ray decay after being irradiated by neutron sourced. Thus, element that cannot be determined by the conventional NAA for example H, B, N, Si and Cd, can be determine by PGNAA. This paper focuses on the technical working procedure for operating portable PGNAA in field work. The device is designed as a portable non-destructive investigation tool applying an isotopic neutron source (Cf-252) and a gamma-ray spectroscopy system for in-situ investigation. The studied have been carried out on Terengganu inscribed stone at Terengganu State Museum. (author)

  5. Characterization of acute undifferentiated leukemia by combined analysis of plasma membrane-associated gamma-glutamyltranspeptidase and soluble terminal transferase.

    Science.gov (United States)

    Heumann, D; Losa, G; Barras, C; Morell, A; von Fliedner, V

    1985-08-01

    gamma-Glutamyltranspeptidase (gamma-GT) is a plasma membrane-associated enzyme present in blasts of certain acute leukemias. We analyzed 90 cases of undifferentiated and differentiated acute leukemias for gamma-GT, using a colorimetric assay. Blasts of all patients with common acute lymphoblastic leukemia (ALL) and T-ALL were negative for gamma-GT (less than 5 units). In contrast, gamma-GT was significantly elevated in acute myeloblastic or monoblastic leukemia blasts (P less than .001). In 16 cases of acute undifferentiated leukemia (AUL) studied, the levels of gamma-GT ranged from 0 to 93 units; in eight cases, gamma-GT was positive (greater than 5 units), and six of these had 2% to 5% Sudan black-positive leukemic cells in the blast-enriched suspension. Combined gamma-GT/TdT analysis revealed that both enzyme markers were mutually exclusive in 75% of AUL cases, suggesting that gamma-GT+/TdT-blasts are of nonlymphoid origin, and gamma-GT-/TdT+ blasts are of lymphoid origin. Two cases were devoid of both enzyme activities and could represent truly undifferentiated leukemia. Thus, combined gamma-GT/TdT analysis underlines the heterogeneity of AUL and appears to be useful in defining the lineage commitment of undifferentiated leukemic blasts.

  6. Determination of gold in lump by the gamma-activation analysis method

    International Nuclear Information System (INIS)

    Yantsen, V.A.; Ermakov, K.S.

    2006-01-01

    Full text: In the report the installation is described used in the Central gamma-activation analysis laboratory (CGAAL) for express quantitative determination of gold concentration in large powdered samples. The method of gold contents determination for non-crushed samples (pieces up to 100 mm). The given gamma-activation analysis method is widely used in mining industry, and at researches related with selection of optimal technological circuits designed for sorting the pieces of ore and rock materials. By developing this method it is now possible to create the technological collection of separated pieces by size, large by the amount of samples, imitating various sorts (by gold concentration in them) and types (by elemental composition) ores, and, based on these collection, to compare the efficiencies of various enrichment methods by knowing in advance the concentrations of gold in these lumps being the final sorting products. The Gamma-activation analysis method of large pieces is mainly used as foundation for the x-ray radiometric (XRR) method of pieces separation of gold-bearing ores from the deposits mined by the Navoi mining combine. It allows significant increase in the rate of research and development works on selection of the most reliable separation characteristics. Based on these one can develop optimal technological circuits for ore enrichment with portion sorting methods. (author)

  7. Analysis of gamma irradiator dose rate using spent fuel elements with parallel configuration

    International Nuclear Information System (INIS)

    Setiyanto; Pudjijanto MS; Ardani

    2006-01-01

    To enhance the utilization of the RSG-GAS reactor spent fuel, the gamma irradiator using spent fuel elements as a gamma source is a suitable choice. This irradiator can be used for food sterilization and preservation. The first step before realization, it is necessary to determine the gamma dose rate theoretically. The assessment was realized for parallel configuration fuel elements with the irradiation space can be placed between fuel element series. This analysis of parallel model was choice to compare with the circle model and as long as possible to get more space for irradiation and to do manipulation of irradiation target. Dose rate calculation were done with MCNP, while the estimation of gamma activities of fuel element was realized by OREGEN code with 1 year of average delay time. The calculation result show that the gamma dose rate of parallel model decreased up to 50% relatively compared with the circle model, but the value still enough for sterilization and preservation. Especially for food preservation, this parallel model give more flexible, while the gamma dose rate can be adjusted to the irradiation needed. The conclusion of this assessment showed that the utilization of reactor spent fuels for gamma irradiator with parallel model give more advantage the circle model. (author)

  8. Scintigraphic characteristics of experimental myocardial infarct extension

    International Nuclear Information System (INIS)

    Kronenberg, M.W.; Wooten, N.E.; Friesinger, G.C.; Page, D.L.; Higgins, S.B.; Collins, J.C.; O'Connor, J.L.; Price, R.R.; Brill, A.B.

    1979-01-01

    Technetium-99m-stannous pyrophosphate scintiphotos were evaluated for diagnosing and quantitating myocardial infarct (MI) extension in sedated dogs. Infarction and extension were produced by serial left anterior descending coronary artery ligations at 0 and 48 hours. We compared serial scintiphoto data with regional myocardial blood flow (MBF) (microsphere technique) and infarct histopathology. In eight control dogs, the scintigraphic MI area was stable at 24, 48, and 72 hours. In each of 11 dogs undergoing extension, the MI area increased after the 48-hour occlusion, averaging a 48.9% increase (p < 0.001). Grossly, most extensions were mixtures of confluent necrosis and moderate (patchy) necrosis. MBF to confluent infarct tissue decreased significantly, allowing the documentation of extension by totaling the grams of newly flow-deprived tissue, but patchy infarct tissue had little flow deprivation, making it difficult to quantitate this type of extension accurately by flow criteria alone. Rarely, extension could be diagnosed using conventional histologic criteria. We concluded that the scintiphoto MI area was related quantitatively to infarct weight in both control and extension. However, it was not possible to determine that an increase in the MI scintiphoto area was an accurate predictor of the degree of extension using independent flow or pathologic criteria

  9. Measurements of Soil Carbon by Neutron-Gamma Analysis in Static and Scanning Modes.

    Science.gov (United States)

    Yakubova, Galina; Kavetskiy, Aleksandr; Prior, Stephen A; Torbert, H Allen

    2017-08-24

    The herein described application of the inelastic neutron scattering (INS) method for soil carbon analysis is based on the registration and analysis of gamma rays created when neutrons interact with soil elements. The main parts of the INS system are a pulsed neutron generator, NaI(Tl) gamma detectors, split electronics to separate gamma spectra due to INS and thermo-neutron capture (TNC) processes, and software for gamma spectra acquisition and data processing. This method has several advantages over other methods in that it is a non-destructive in situ method that measures the average carbon content in large soil volumes, is negligibly impacted by local sharp changes in soil carbon, and can be used in stationary or scanning modes. The result of the INS method is the carbon content from a site with a footprint of ~2.5 - 3 m 2 in the stationary regime, or the average carbon content of the traversed area in the scanning regime. The measurement range of the current INS system is >1.5 carbon weight % (standard deviation ± 0.3 w%) in the upper 10 cm soil layer for a 1 hmeasurement.

  10. Medicina nucleara: introducerea in computerizarea investigatiei in vivo cu radionuclizi

    International Nuclear Information System (INIS)

    Mateescu, Gh.; Dumitriu, L.; Notas, E.

    1981-12-01

    Firstly some bgsical aspects of nuclear medicine in vivo procedures along with the requirements for digital data handling in scintigraphic process are synthetically presented from the technical point of view. The essential features needed to interface an usual (Anger) gammacamera to a general-purpose computer are next underlined also emphasizing that an optional configuration for a computerized scintigraphic system could be implemented using a CORAL-4q11 minicomputer. Finally a system of programs, termed GAMMA-11, extensively used for scintigraphic studies is described together with a set of original algorithms which have been implemented as new FORTRAN programs and modularly included within this system. (authors)

  11. An Exact Solution of the Gamma Ray Burst Arrival Time Analysis ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    An Exact Solution of the Gamma Ray Burst Arrival Time Analysis. Problem. S. Sinha ISRO Satellite Center, Bangalore 560 017, India. Abstract. An analytical solution of the GRB arrival time analysis is presented. The errors in the position of the GRB resulting from timing and position errors of different satellites are calculated.

  12. Computational techniques in gamma-ray skyshine analysis

    International Nuclear Information System (INIS)

    George, D.L.

    1988-12-01

    Two computer codes were developed to analyze gamma-ray skyshine, the scattering of gamma photons by air molecules. A review of previous gamma-ray skyshine studies discusses several Monte Carlo codes, programs using a single-scatter model, and the MicroSkyshine program for microcomputers. A benchmark gamma-ray skyshine experiment performed at Kansas State University is also described. A single-scatter numerical model was presented which traces photons from the source to their first scatter, then applies a buildup factor along a direct path from the scattering point to a detector. The FORTRAN code SKY, developed with this model before the present study, was modified to use Gauss quadrature, recent photon attenuation data and a more accurate buildup approximation. The resulting code, SILOGP, computes response from a point photon source on the axis of a silo, with and without concrete shielding over the opening. Another program, WALLGP, was developed using the same model to compute response from a point gamma source behind a perfectly absorbing wall, with and without shielding overhead. 29 refs., 48 figs., 13 tabs

  13. Relevance of 123I-BMIPP delayed scintigraphic imaging for patients with angina pectoris ? a pilot study

    OpenAIRE

    Koyama, Kohei; Akashi, Yoshihiro J.; Kida, Keisuke; Suzuki, Kengo; Ishibashi, Yuki; Musha, Haruki; Banach, Maciej

    2011-01-01

    Introduction The study was designed to clarify the role of 123I-?-methyl-iodophenylpentadecanoic acid (123I-BMIPP) in the evaluation of myocardial fatty acid metabolism in patients with stable angina pectoris (AP) before and after percutaneous coronary intervention (PCI). Material and methods Ten controls (mean age: 70.4 ?10.5 years) and 12 patients with AP (mean age: 67.4 ?11.6 years) and single vessel coronary artery disease participated in the radionuclide cardiac study. Scintigraphic imag...

  14. Scintigraphic detection of remote transmural myocardial infarction with thallium-201

    International Nuclear Information System (INIS)

    Silber, S.; Fleck, E.; Bierner, M.; Klein, U.; Rudolph, W.

    1979-01-01

    This study was undertaken to assess the value of the thallium-201-scintigram in the detection of remote myocardial infarction with respect to localization and extent as well as the degree of impairment of left ventricular wall motion. 114 patients with typical history of infarction, unequivocal ECG changes and angiographically-documented irreversible asynergy were investigated and 25 healthy subjects served as controls. Electrocardiographic classification of infarction as extensive or non-extensive was based on number of leads involved. The thallium-201-scintigrams were visually analyzed for evaluation of each of 3 segments in all 6 recorded projections. The angiograms were evaluated with respect to regional wall motion derived for the semi-axis shortening of the 3 corresponding scintigraphic segments in the right and left anterior oblique projections. Standard classification of localization and degree of asynergy were employed. (orig.) 891 AJ/orig. 892 MB [de

  15. Recent advances in segmented gamma scanner analysis

    International Nuclear Information System (INIS)

    Sprinkle, J.K. Jr.; Hsue, S.T.

    1987-01-01

    The segmented gamma scanner (SGS) is used in many facilities to assay low-density scrap and waste generated in the facilities. The procedures for using the SGS can cause a negative bias if the sample does not satisfy the assumptions made in the method. Some process samples do not comply with the assumptions. This paper discusses the effect of the presence of lumps on the SGS assay results, describes a method to detect the presence of lumps, and describes an approach to correct for the lumps. Other recent advances in SGS analysis are also discussed

  16. The Analysis Of Spent Fuel Utilization For A Gamma Irradiator

    International Nuclear Information System (INIS)

    MS, Pudjijanto; Setiyanto

    2002-01-01

    The gamma irradiator using RSG-GAS spent fuels was analyzed. The cylindrical geometry of the irradiator was designed by locating the spent fuels the cylindrical periphery. The analysis was focused to evaluate the feasibilities of the irradiator as a fruits and vegetables irradiator. The spent fuels activities were calculated using Origen2 code, while the dose rate at the irradiation positions was determined by linear attenuation model with transport coefficient. The evaluated results showed that the cylindrical geometry of irradiators with diameter around 1-1.5 m gave the effective dose rate for fruits and vegetables preservation. It can be concluded that one can use the RSG-GAS spent fuels effectively as a gamma irradiator for certain applications

  17. Causes of appearance of scintigraphic hot areas on thyroid scintigraphy analyzed with clinical features and comparative ultrasonographic findings

    Energy Technology Data Exchange (ETDEWEB)

    Iwata, Masahiro [Hikone Municipal Hospital, Shiga (Japan); Kasagi, Kanji [Takamatsu Red Cross Hospital, Kagawa (Japan); Hatabu, Hiroto [Univ. of Pennsylvania Medical Center, PA (United States); Misaki, Takashi; Iida, Yasuhiro; Fujita, Toru; Konishi, Junji [Kyoto Univ. (Japan). Graduate School of Medicine

    2002-06-01

    This study was done retrospectively to analyze the ultrasonographic (US) findings in thyroid scintigraphic hot areas (HA). Three-thousand, eight-hundred and thirty-nine consecutive patients who underwent {sup 99m}Tc-pertechnetate (n=3435) or {sup 123}I (n=457) scintigraphy were analyzed. HA were regarded as present when the tracer concentration was greater than the remaining thyroid tissue, or when hemilobar uptake was observed. High-resolution US examinations were performed with a real-time electronic linear scanner with a 7.5 or 10 MHz transducer. One hundred and four (2.7%) were found to be scintigraphic HA (n=120). US revealed a nodular lesion or well-demarcated thyroid tissue corresponding to the HA in 94 areas (78.4%, Category 1), an ill-defined region with different echogenicity in 13 areas (10.8%, Category 2), and no correlating lesion in 13 areas (10.8%, Category 3). These 104 patients included 43 with adenomatous goiter (59 areas), 33 with adenoma, 11 with Hashimoto's thyroiditis, 5 with primary thyroid cancer, 4 with euthyroid ophthalmic Graves' disease (EOG), 3 with hemilobar atrophy or hypogenesis, 2 with hemilobar agenesis, 2 with hypothyroidism with blocking-type TSH-receptor antibodies (TSHRAb), 1 with acute suppurative thyroiditis. Among the 59 adenomatous nodules and 33 adenomas, 51 (86.4%) and 32 (97.0%), respectively, belonged to Category 1. A solitary toxic nodule was significantly larger and occurs more often in older patients than in younger patients. On the other hand, all 17 patients with known autoimmune thyroid diseases including Hashimoto's thyroiditis, EOG and hypothyroidism with blocking TSHRAb belonged to Category 2 or 3. Possible underlying mechanisms are hyperfunctioning tumors or nodules, localized functioning thyroid tissue freed from autoimmune destruction, inflammation or tumor invasion, congenital abnormality, clusters of hyperactive follicular cells caused by long-term TSH and/or TSHRAb stimulation, asymmetry

  18. Causes of appearance of scintigraphic hot areas on thyroid scintigraphy analyzed with clinical features and comparative ultrasonographic findings

    International Nuclear Information System (INIS)

    Iwata, Masahiro; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Fujita, Toru; Konishi, Junji

    2002-01-01

    This study was done retrospectively to analyze the ultrasonographic (US) findings in thyroid scintigraphic hot areas (HA). Three-thousand, eight-hundred and thirty-nine consecutive patients who underwent 99m Tc-pertechnetate (n=3435) or 123 I (n=457) scintigraphy were analyzed. HA were regarded as present when the tracer concentration was greater than the remaining thyroid tissue, or when hemilobar uptake was observed. High-resolution US examinations were performed with a real-time electronic linear scanner with a 7.5 or 10 MHz transducer. One hundred and four (2.7%) were found to be scintigraphic HA (n=120). US revealed a nodular lesion or well-demarcated thyroid tissue corresponding to the HA in 94 areas (78.4%, Category 1), an ill-defined region with different echogenicity in 13 areas (10.8%, Category 2), and no correlating lesion in 13 areas (10.8%, Category 3). These 104 patients included 43 with adenomatous goiter (59 areas), 33 with adenoma, 11 with Hashimoto's thyroiditis, 5 with primary thyroid cancer, 4 with euthyroid ophthalmic Graves' disease (EOG), 3 with hemilobar atrophy or hypogenesis, 2 with hemilobar agenesis, 2 with hypothyroidism with blocking-type TSH-receptor antibodies (TSHRAb), 1 with acute suppurative thyroiditis. Among the 59 adenomatous nodules and 33 adenomas, 51 (86.4%) and 32 (97.0%), respectively, belonged to Category 1. A solitary toxic nodule was significantly larger and occurs more often in older patients than in younger patients. On the other hand, all 17 patients with known autoimmune thyroid diseases including Hashimoto's thyroiditis, EOG and hypothyroidism with blocking TSHRAb belonged to Category 2 or 3. Possible underlying mechanisms are hyperfunctioning tumors or nodules, localized functioning thyroid tissue freed from autoimmune destruction, inflammation or tumor invasion, congenital abnormality, clusters of hyperactive follicular cells caused by long-term TSH and/or TSHRAb stimulation, asymmetry, etc. Scintigraphic HA are

  19. Causes of appearance of scintigraphic hot areas on thyroid scintigraphy analyzed with clinical features and comparative ultrasonographic findings.

    Science.gov (United States)

    Iwata, Masahiro; Kasagi, Kanji; Hatabu, Hiroto; Misaki, Takashi; Iida, Yasuhiro; Fujita, Toru; Konishi, Junji

    2002-06-01

    This study was done retrospectively to analyze the ultrasonographic (US) findings in thyroid scintigraphic hot areas (HA). Three-thousand, eight-hundred and thirty-nine consecutive patients who underwent 99mTc-pertechnetate (n = 3435) or 123I (n = 457) scintigraphy were analyzed. HA were regarded as present when the tracer concentration was greater than the remaining thyroid tissue, or when hemilobar uptake was observed. High-resolution US examinations were performed with a real-time electronic linear scanner with a 7.5 or 10 MHz transducer. One hundred and four (2.7%) were found to be scintigraphic HA (n = 120). US revealed a nodular lesion or well-demarcated thyroid tissue corresponding to the HA in 94 areas (78.4%, Category 1), an ill-defined region with different echogenicity in 13 areas (10.8%, Category 2), and no correlating lesion in 13 areas (10.8%, Category 3). These 104 patients included 43 with adenomatous goiter (59 areas), 33 with adenoma, 11 with Hashimoto's thyroiditis, 5 with primary thyroid cancer, 4 with euthyroid ophthalmic Graves' disease (EOG), 3 with hemilobar atrophy or hypogenesis, 2 with hemilobar agenesis, 2 with hypothyroidism with blocking-type TSH-receptor antibodies (TSHRAb), I with acute suppurative thyroiditis. Among the 59 adenomatous nodules and 33 adenomas, 51 (86.4%) and 32 (97.0%), respectively, belonged to Category 1. A solitary toxic nodule was significantly larger and occurs more often in older patients than in younger patients. On the other hand, all 17 patients with known autoimmune thyroid diseases including Hashimoto's thyroiditis, EOG and hypothyroidism with blocking TSHRAb belonged to Category 2 or 3. Possible underlying mechanisms are 1) hyperfunctioning tumors or nodules, 2) localized functioning thyroid tissue freed from autoimmune destruction, inflammation or tumor invasion, 3) congenital abnormality, 4) clusters of hyperactive follicular cells caused by long-term TSH and/or TSHRAb stimulation, 5) asymmetry, etc

  20. A gamma scintigraphic study to compare oesophageal clearance of 'Expidet' formulations, tablets and capsules in supine volunteers

    International Nuclear Information System (INIS)

    Wilson, C.G.; Washington, N.; Norman, S.; Greaves, J.L.

    1988-01-01

    The relative rates of transit through the oesophagus of radiolablled 'Expidet' formulations, tablets, capsules or liquids were measured in 10 healthy supine male and female subjects. The movement of the formulations was followed by gamma scintigraphy. Liquids were observed to clear rapidly in a monoexponential pattern in all subjects. The transit of capsules and tablets in the same subjects was slower and more variable. In two subjects, capsules and tablets were observed to lodge in the lower third of the oesophagus. The 'Expidet' formulations cleared from the mouth with several swallows and there was no evidence of oesophageal adhesion. There was no satistically significant difference in total transmit time between the formulations

  1. Scintigraphic evaluation of soft tissue tumors with technetium(V)-99m dimercaptosuccinic acid, a new tumor seeking radiopharmaceutical

    International Nuclear Information System (INIS)

    Ohta, H.; Yoshizumi, M.; Endo, K.; Torizuka, K.; Yokoyama, A.; Yamamoto, K.

    1984-01-01

    Recently, a very promising tumor seeking agent, a Tc(V)-99m dimercaptosuccinic acid (Tc(V)-DMS), which was labelled under optimal pH 8 and very low SnCl/sub 2/ concentrations, has been developed. An equilibrium between a stable form and a dissociated form of anion TcO/sub 4//sup 3-/, structural similarity to PO/sub 4//sup 3-/, postulated for tumor uptake. And the authors have previously reported that Tc(V)-DMS scintigram would be useful in the diagnosis of medullary thyroid carcinoma. In an attempt to widen its applicability, the scintigraphic examinations of soft tissue tumors with Tc(V)-DMS and comparative study with Ga-67 citrate were performed in 58 patients. Scintigrams were made 60-120 min after i.v. administration of 10 mCi Tc(V)-DMS using a conventional gamma camera. Tc(V)-DMS was found to have superior sensitivity of 90% for malignant tumors (including aggressive fibromatosis) to that with Ga-67 citrate of 56%, but inferior specificity of 71% to that with Ga-67 citrate of 80%. And the accuracy of the scan in soft tissue tumors with Tc(V)-DMS and Ga-67 citrate was 78% and 71%, respectively. Although the accumulation of Tc(V)-DMS has been detected in some benign soft tissue tumors and the exact mechanism of Tc(V)-DMS accumulation remains to be elucidated, these data indicated that Tc(V)-DMS scintigraphy would be of great use in the detection of extension or location of malignant soft tissue tumors

  2. Natural gamma ray spectrum analysis technique

    International Nuclear Information System (INIS)

    Chevalier, P.; Seeman, B.

    1976-01-01

    In accordance with an illustrative embodiment of the present invention, a method and apparatus is disclosed for determining the presence of a selected number of naturally radioactive materials in an earth formation from the spectrum of natural gamma radiation emitted by the materials in the formation by deriving representations of portions of the detected gamma radiation spectrum and combining the representations to determine therefrom the presence of the selected materials

  3. The use of combined three-dimensional electron backscatter diffraction and energy dispersive X-ray analysis to assess the characteristics of the gamma/gamma-prime microstructure in alloy 720Li Trade-Mark-Sign

    Energy Technology Data Exchange (ETDEWEB)

    Child, D.J., E-mail: d.child@lboro.ac.uk [Department of Materials, Loughborough University, Loughborough, Leicestershire, LE11 3TU (United Kingdom); West, G.D., E-mail: g.west@lboro.ac.uk [Department of Materials, Loughborough University, Loughborough, Leicestershire, LE11 3TU (United Kingdom); Thomson, R.C., E-mail: r.c.thomson@lboro.ac.uk [Department of Materials, Loughborough University, Loughborough, Leicestershire, LE11 3TU (United Kingdom)

    2012-03-15

    Multiple three-dimensional reconstructions of a {gamma}/{gamma} Prime phase structure in Alloy 720Li have been carried out by employing a serial milling technique with simultaneous electron backscatter diffraction (EBSD) and energy dispersive x-ray (EDX) analysis data collection. Combining EBSD data with EDX is critical in obtaining maps to distinguish between the chemically differing, but crystallographically similar {gamma} and {gamma} Prime phases present in the alloy studied. EDX is shown to allow the differentiation of {gamma} and {gamma} Prime phases, with EBSD providing increased grain shape accuracy. The combination of data sources also allowed identification of coherent {gamma}/{gamma} Prime phase interfaces that would not be identified using solely EBSD or EDX. The study identifies a region of grain banding within the alloy, which provides the basis for a three-dimensional comparison and discussion of {gamma} Prime phase size between coarse and fine grain regions, whilst also identifying coherent {gamma} Prime phase interfaces, possible only using both EDX and EBSD systems simultaneously. The majority of the {gamma} Prime phase lies in the range of 1-10 {mu}m in non-banded regions, with a detectable particle size limit of 500 nm being established. The validity of the reconstruction has been demonstrated using an electron interaction volumes model, and an assessment of the validity of EBSD and EDX data sources is discussed showing {gamma} Prime phase connectivity in all dimensions. -- Highlights: Black-Right-Pointing-Pointer Use of combined EBSD/EDX for the 3D analysis of gamma prime in a Ni-based alloy. Black-Right-Pointing-Pointer Assessment of 3D reconstruction accuracy using CASINO. Black-Right-Pointing-Pointer Observation and validation of gamma prime phase connectivity throughout the alloy. Black-Right-Pointing-Pointer Identification and characterisation of grain banding in gamma prime. Black-Right-Pointing-Pointer Distinction of phase coherency

  4. Feasibility study of plutonium isotopic analysis of resin beads by nondestructive gamma-ray spectroscopy

    International Nuclear Information System (INIS)

    Li, T.K.

    1985-01-01

    We have initiated a feasibility study on the use of nondestructive low-energy gamma-ray spectroscopy for plutonium isotopic analysis on resin beads. Seven resin bead samples were measured, with each sample containing an average of 9 μg of plutonium; the isotopic compositions of the samples varied over a wide range. The gamma-ray spectroscopy results, obtained from 4-h counting-time measurements, were compared with mass spectrometry results. The average ratios of gamma-ray spectroscopy to mass spectrometry were 1.014 +- 0.025 for 238 Pu/ 239 Pu, 0.996 +- 0.018 for 240 Pu/ 239 Pu, and 0.980 +- 0.038 for 241 Pu/ 239 Pu. The rapid, automated, and accurate nondestructive isotopic analysis of resin beads may be very useful to process technicians and International Atomic Energy Agency inspectors. 3 refs., 1 fig., 3 tabs

  5. Evaluation of uncertainties in the gamma-ray heating analysis of a PWR

    International Nuclear Information System (INIS)

    West, J.T.

    1977-01-01

    The limits of accuracy in a PWR gamma heating analysis, which used conventional one- and two-dimensional discrete ordinate transport methods, by utilizing three-dimensional Monte Carlo methods are determined

  6. Automatic analysis algorithm for radionuclide pulse-height data from beta-gamma coincidence systems

    International Nuclear Information System (INIS)

    Foltz Biegalski, K.M.

    2001-01-01

    There are two acceptable noble gas monitoring measurement modes for Comprehensive Nuclear-Test-Ban-Treaty (CTBT) verification purposes defined in CTBT/PC/II/WG.B/1. These include beta-gamma coincidence and high-resolution gamma-spectrometry. There are at present no commercial, off-the-shelf (COTS) applications for the analysis of β-γ coincidence data. Development of such software is in progress at the Prototype International Data Centre (PIDC) for eventual deployment at the International Data Centre (IDC). Flowcharts detailing the automatic analysis algorithm for β-γ coincidence data to be coded at the PIDC is included. The program is being written in C with Oracle databasing capabilities. (author)

  7. Comparative considerations concerning scintigraphy, arteriography and reverse ductography in pancreas diseases

    Energy Technology Data Exchange (ETDEWEB)

    Romani, S; Oselladore, D; Feltrin, G P; Ravasini, R; Zacchi, C; Di Maggio, C; Vedaldi, R; Vio, S; Maffessanti, M; Perelli, R [Padua Univ. (Italy)

    1975-01-01

    Disregarding the actual nature of the diagnosis of pancreatic disease, scintigraphy with labeled selenomethionine significantly reveals pathological disorders, however general they may be. In the recognition of ''scintigraphically normal'' the homogeneous results of a linear scan are distributed on values of 85% and results with the gamma-camera on values of 88%. The scintigraphic response remains even more homogeneous with the pathologic pancreas, e.g. in chronic pancreatitis and cancer, where linear scintigraphy yields correct diagnoses in 84% and 92% of the cases, and the gamma-camera in 84% and 93% of the cases, respectively. In summary, scintigraphy offers an important identification of the normal, and a high percentage of correct diagnoses in the pathological realm; thus, it represents the most appropriate means for detection at the pancreatic level. The methodological choice based on clinical data first takes scintigraphic data and incorporates them with arteriography in the case of suspected carcinomas or with ductography when chronic pancreatitis is believed to exist. Arteriography has priority in the localization of adenomas, while ductography is relied upon in the diagnosis of pseudocysts.

  8. Comparative functional scintigraphic and angiographic examination in pancreas diseases

    International Nuclear Information System (INIS)

    Mendizov, A.; Brilski, V.; Bozhiyanov, A.; Romanova, A.; Mardzhanov, I.; Glavincheva, I.; Meditsinska Akademiya, Sofia

    1979-01-01

    Pancreas scintigraphy with 75 seleno-methionine, pancreocimine-secretine test and selective abdominal angiography was carried out in patients with chronic pancreatitis, pancreas carcinoma and subjects without any pancreas diseases. Scintigraphic changes in pancreas was found in 95,6 per cent of the patients with chronic pancreatitis (136 patients), in 92 per cent of them with pancreas carcinoma (25 patients) and in 53,4 per cent from the subjects without pancreas diseases (30 examined). Pathological changes in pancreatic secretion was found in 93,4 per cent of the patients with chronic pancreatitis (105 patients), in 93,8 per cent of the subjects with pancreas carcinoma (32 patients) and only in 3,9 per cent from the examined without pancreatic diseases. The angiographic examination is informative mainly in case of tumours and cysts of the pancreas. The diagnostic potentialities of the separate methods for pancreas examination were critically assessed. The basic diagnostic problems in pancreas diseases are solved to a great extent with the combined examination with scintigraphy pancreocimine test and angiography (76 patients). (author)

  9. Prompt gamma neutron activation analysis facility at the RA-6 research reactor

    International Nuclear Information System (INIS)

    Sanchez, F. A.; Calzetta, O

    2004-01-01

    A prompt gamma neutron activation activation analysis facility was developed at the 500 kw thermal power RA-6 research reactor of the Bariloche Atomic Center, Argentina.This facility consist of a radial beam port with external positioning of the sample.The gamma radiation is reduced by a bismuth filter placed inside the extraction tube and the beam diameter is limited by a set of two collimators up to 5 cm.The neutron flux at the sample position is 7 10 6 n/cm 2 s with a Cadmium ratio of 20/1.The gamma detector is a 50 % efficiency type p HPGe rounded by a NaI(Tl) for Compton suppressioning.The gamma spectra is measured through 0 to 8.5 MeV.The background have counting rate of 350 cps without sample. In this work is shown the efficiency curve, the calculed sensibilities and the lower detection limits for B, Cd, Sm, Gd, H, Cl, Hg, Eu, Ti, Ag, Au, Mo. The RA-6's PGNAA facility is fully working, although the analytic capacity is under improvement [es

  10. Several experimental applications of gamma ray spectrometry on the analysis of uranium compounds

    International Nuclear Information System (INIS)

    Korob, Ricardo O.; Blasiyh Nuno, Guillermo A.

    2002-01-01

    Several experimental applications of gamma ray spectrometry on the analysis of uranium compounds and materials containing it are studied. Special attention is devoted to the correlation between experimental spectra and the decay chains of 235 U and 238 U contained in the analyzed samples. The following applications are discussed: enrichment determination without using calibration standards, determination of uranium concentration, intensities of the gamma rays emitted by the nuclides present in the decay chains of study and the activity of such nuclides. Because of its importance, detailed discussion about the former one is shown. In addition, preliminary results regarding the emission probabilities of the most important gamma rays of 234m Pa are also informed. (author)

  11. modern utilization of accurate methods for gamma-ray spectral analysis detected by high pure germanium (HPGE) detectors through different applications

    International Nuclear Information System (INIS)

    El-Sayed, M.M.

    2006-01-01

    this thesis presents a novel way for application of wavelet transform theory in gamma-ray spectroscopy . this technique was applied for searching real and weak peaks, solving problem of multiplets, smoothing and de-noising gamma-ray spectra, and using artificial neural network for identifying peaks. a brief description about gamma-ray spectrum analysis is presented. we discussed the necessary formulas and algorithms of wavelet theory to solve these main problems in gamma -ray spectrum analysis. the algorithm of peak search was applied on different types of spectra, IAEA spectra and other sources of gamma spectra. the algorithm of multiplets algorithm was applied successfully on different types of multiplets. the algorithm of de noising was applied successfully on different sources of spectra.finally, a database for neutron activation laboratory is created. this data base consists of five routines, wavelet gamma spectrum analysis, peak identification, elemental concentration , neutron flux determination,and detector efficiency calculation

  12. Spectrum analysis with indoor multi-channels gamma-rays spectrometer (NaI(Tl))

    International Nuclear Information System (INIS)

    Hou Shengli; Fan Weihua

    2005-01-01

    Two calculational methods for analyzing the spectrum which measured by indoor low background multi-channels gamma-rays spectrometer (Na(Tl)) to get the specific activity of 226 Ra, 232 Th and 40 K of the sample are discussed, they are the spectrum analysis method and the characteristic energy peak method (inverse matrix method) respectively. The sample spectrum are analyzed with the program designed according to the two methods, and compared with the results by HPGe gamma-rays spectrometer, showing that the relative deviation is ≤10% with the two methods. (authors)

  13. Diagnostic accuracy of scintigraphic methods in the differential diagnosis of focal liver lesions

    International Nuclear Information System (INIS)

    Czermak, H.; Gomez, I.; Gallowitsch, H.J.; Lind, P.

    1993-01-01

    In a retrospective study of 160 patients who were examined within 12 months, we analysed the diagnosic value of scintigraphic techniques in the differential diagnosis of solid focal liver lesions. Haemangiomas were found in 77 patients. Bloodpool scintigraphy was true-positive in 66 (sensivitity 85%); for lesions greater than 2 cm in diameter, sensitivity increased to 94%. Metastases of CEA-expressing tumors were found in 42 patients, anti-CEA-immunoscintigraphy was true-positive in 33 patients (sensitivity 78.5%). Focal nodulary hyperplasia was found in 3 patients, adenomas in 6 patients. In the remaining 32 patiens we saw 4 hepatocellular carcinomas, 28 metastases from lung and breast cancer, 2 echinococcus cysts and 1 choledochus cyst. (orig.) [de

  14. Novel CT and scintigraphic findings of bone metastasis from invasive lobular breast cancer

    International Nuclear Information System (INIS)

    Al-Ogaili, Zeyad; Troedson, Russell

    2016-01-01

    The aim of this study is to identify and describe the computed tomography and scintigraphic imaging patterns of osseous metastasis from invasive lobular breast cancer (ILC). CT and skeletal scintigraphy (SS) studies of 23 patients with diagnosis of ILC and osseous metastasis on their initial presentation were reviewed.Osseous metastases in 14 patients (60.8%) appear as uniform small sclerotic lesions (USSL) on CT scan. The SS in these patients were interpreted as negative for metastasis (either normal or with some equivocal findings not typical for metastasis). Osseous metastasis from ILC can have a characteristic imaging pattern on CT and SS. The pattern of USSL on CT scan with negative SS is highly suggestive of osseous metastasis from ILC.

  15. Scintigraphic control of bone-fracture healing under ultrasonic stimulation: An animal experimental study

    International Nuclear Information System (INIS)

    Klug, W.; Franke, W.G.; Knoch, H.G.

    1986-01-01

    In a model of closed lower-leg fracture in rabbits and of secondary bone-fracture healing, scintigraphic control until biological healing was performed. Biological fracture healing was assumed for a region of interest (ROI)-activity ratio close to 1.0. After application of sup(99m)Tc-HEDP, 151 examinations were performed. ROI activity increased significantly until day 14 p.i. and reached the maximum value (Q=6.44) on day 14 postfracture. Sixty-one lower leg fractures were treated by ultrasound from days 14-28 postfractures. These stimulated fractures were biologically healed on day 168 postfracture. The fractures that were not treated by ultrasound could not be detected by scanning after day 203 postfracture. (orig.)

  16. Coupling of RELAP5-3D and GAMMA codes for Nuclear Hydrogen System Analysis

    International Nuclear Information System (INIS)

    Jin, Hyung Gon

    2007-02-01

    RELAP5-3D is one of the most important system analysis codes in nuclear field, which has been developed for best-estimate transient simulation of light water reactor coolant systems during postulated accidents. The GAMMA code is a multi-dimensional multi-component mixture analysis code with the complete set of chemical reaction models which is developed for safety analysis of HTGR (High Temperature Gas Cooled Reactor) air-ingress. The two codes, RELAP5-3D and GAMMA, are coupled to be used for nuclear-hydrogen system analysis, which requires the capability of the analysis of multi-component gas mixture and two-phase flow. In order to couple the two codes, 4 steps are needed. Before coupling, the GAMMA code was transformed into DLL (dynamic link liberally) from executive type and RELAP5-3D was recompiled into Compaq Visual Fortran environments for our debugging purpose. As the second step, two programs - RELAP5-3D and GAMMA codes - must be synchronized in terms of time and time step. Based on that time coupling, the coupled code can calculate simultaneously. Time-step coupling had been accomplished successfully and it is tested by using a simple test input. As a next step, source-term coupling was done and it was also tested in two different test inputs. The fist case is a simple test condition, which has no chemical reaction. And the other test set is the chemical reaction model, including four non-condensable gas species, which are He, O2, CO, CO2. Finally, in order to analyze combined cycle system, heat-flux coupling has been made and a simple heat exchanger model was demonstrated

  17. In situ analysis of coal by scintillation gamma-ray spectrometry in deep boreholes

    International Nuclear Information System (INIS)

    Chrusciel, E.; Kopec, M.; Niewodniczanski, J.; Palka, K.W.; Kaczmarski, S.M.; Wojda, F.

    1987-01-01

    Neutron-gamma and gamma-gamma spectrometric loggings have been used for evaluation of coal seams. Interpretation of the logging curves was based on the method of spectrometric parameters i.e. the ratios of gamma-ray intensities recorded within two energy intervals, which depended strongly on a given parameter of coal, while the influence of other parameters is reduced. The boundaries of energy intervals were chosen by multiple correlation analysis of the results of point measurements and results of coal samples assessments. These energy intervals are later used in continuous borehole logging. Some of the coal parameters can be determined by both logging methods, other by one method only. The logging tools are described and examples of the determination of carbon, sulphur, iron, calcium, ash content, calorific value, density and moisture of coal are given. The agreement with the results of laboratory analyses seems quite satisfactory, especially when the calibration procedure was made for the same part of a coal basin. 13 refs., 6 figs., 5 tabs. (author)

  18. Gamma radiation shielding analysis of lead-flyash concretes

    International Nuclear Information System (INIS)

    Singh, Kanwaldeep; Singh, Sukhpal; Dhaliwal, A.S.; Singh, Gurmel

    2015-01-01

    Six samples of lead-flyash concrete were prepared with lead as an admixture and by varying flyash content – 0%, 20%, 30%, 40%, 50% and 60% (by weight) by replacing cement and keeping constant w/c ratio. Different gamma radiation interaction parameters used for radiation shielding design were computed theoretically and measured experimentally at 662 keV, 1173 keV and 1332 keV gamma radiation energy using narrow transmission geometry. The obtained results were compared with ordinary-flyash concretes. The radiation exposure rate of gamma radiation sources used was determined with and without lead-flyash concretes. - Highlights: • Concrete samples with lead as admixture were casted with flyash replacing 0%, 20%, 30%, 40%, 50% and 60% of cement content (by weight). • Gamma radiation shielding parameters of concretes for different gamma ray sources were measured. • The attenuation results of lead-flyash concretes were compared with the results of ordinary flyash concretes

  19. SU-F-T-236: Comparison of Two IMRT/VMAT QA Systems Using Gamma Index Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, N [University of Miami, Miami, FL (United States); Denissova, S [Sylvester Comprehensive Cancer Center Deerfield, Weston, FL (United States)

    2016-06-15

    Purpose: The goal of this study is to assess differences in the Gamma index pass rates when using two commercial QA systems and provide optimum Gamma index parameters for pre-treatment patient specific QA. Methods: Twenty-two VMAT cases that consisted of prostate, lung, head and neck, spine, brain and pancreas, were included in this study. The verification plans have been calculated using AcurosXB(V11) algorithm for different dose grids (1.5mm, 2.5mm, 3mm). The measurements were performed on TrueBeam(Varian) accelerator using both EPID(S1000) portal imager and ArcCheck(SunNuclearCorp) devices. Gamma index criteria variation of 3%/3mm, 2%/3mm, 2%/2mm and threshold (TH) doses of 5% to 50% were used in analysis. Results: The differences in Gamma pass rates between two devices are not statistically significant for 3%/3mm, yielding pass rate higher than 95%. Increase of lower dose TH showed reduced pass rates for both devices. ArcCheck’s more pronounced effect can be attributed to higher contribution of lower dose region spread. As expected, tightening criteria to 2%/2mm (TH: 10%) decreased Gamma pass rates below 95%. Higher EPID (92%) pass rates compared to ArcCheck (86%) probably due to better spatial resolution. Portal Dosimetry results showed lower Gamma pass rates for composite plans compared to individual field pass rates. This may be due to the expansion in the analyzed region which includes pixels not included in the separate field analysis. Decreasing dose grid size from 2.5mm to 1.5mm did not show statistically significant (p<0.05) differences in Gamma pass rates for both QA devices. Conclusion: Overall, both system measurements agree well with calculated dose when using gamma index criteria of 3%/3mm for a variety of VMAT cases. Variability between two systems increases using different dose GRID, TH and tighter gamma criteria and must be carefully assessed prior to clinical use.

  20. New device based on the super spatial resolution (SSR) method

    International Nuclear Information System (INIS)

    Soluri, A.; Atzeni, G.; Ucci, A.; Bellone, T.; Cusanno, F.; Rodilossi, G.; Massari, R.

    2013-01-01

    Recently it have been described that innovative methods, namely Super Spatial Resolution (SSR), can be used to improve the scintigraphic imaging. The aim of SSR techniques is the enhancement of the resolution of an imaging system, using information from several images. In this paper we describe a new experimental apparatus that could be used for molecular imaging and small animal imaging. In fact we present a new device, completely automated, that uses the SSR method and provides images with better spatial resolution in comparison to the original resolution. Preliminary small animal imaging studies confirm the feasibility of a very high resolution system in scintigraphic imaging and the possibility to have gamma cameras using the SSR method, to perform the applications on functional imaging. -- Highlights: • Super spatial resolution brings a high resolution image from scintigraphic images. • Resolution improvement depends on the signal to noise ratio of the original images. • The SSR shows significant improvement on spatial resolution in scintigraphic images. • The SSR method is potentially utilizable for all scintigraphic devices

  1. Formulation of the relationship between indices of neutron-gamma and gamma-gamma method and the percentrage of iron

    International Nuclear Information System (INIS)

    Majorowicz, J.

    1973-01-01

    In this article, the author presents the possibility of a complex utilization of radiometric logging methods, neutron-gamma profiling and gamma-gamma density logging for determining percentage of iron and establishing geophysical possibilities of identifying zones of economically profitable ores in borehole profiles. Figures present the correlations between indices of neutron-gamma and gamma-gamma logging methods and the percentage of iron, as well as the correlation of neutron-gamma and gamma-gamma indices for zones minerallized with iron ores. The article presents the correlational analyses of the results: the correlational coefficients are given as well as total error in determining iron content on the basis of each of the methods described. Next, a multidimensional statistical analysis is carried out on the results obtained. On the basis of the two-dimensional correlational coefficients calculated and the average standard deviation, an equation of linear regression was formulated, simultaneously involving three parameters - the indices of neutron-gamma and gamma-gamma logging and the percentage of iron. The multiple correlational coefficient obtained markedly exceeds the two-dimentional correlation coefficient (r=0.974>rsub(xz)>rsub(yz)>rsub(xy)). The given method of utilizing multidimensional statistics in borehole geophysics for identifying iron ores is an efficient one. On the basis of several relationships among independent variables which are less obvious (smaller values of correlational coefficient), it is possible to obtain a single distinct relationship involving all variables simultaneously. (author)

  2. Database of prompt gamma rays from slow neutron capture for elemental analysis

    International Nuclear Information System (INIS)

    Firestone, R.B.; Choi, H.D.; Lindstrom, R.M.; Molnar, G.L.; Mughabghab, S.F.; Paviotti-Corcuera, R.; Revay, Zs; Trkov, A.; Zhou, C.M.; Zerkin, V.

    2004-01-01

    The increasing importance of Prompt Gamma-ray Activation Analysis (PGAA) in a broad range of applications is evident, and has been emphasized at many meetings related to this topic (e.g., Technical Consultants' Meeting, Use of neutron beams for low- and medium-flux research reactors: radiography and materials characterizations, IAEA Vienna, 4-7 May 1993, IAEA-TECDOC-837, 1993). Furthermore, an Advisory Group Meeting (AGM) for the Coordination of the Nuclear Structure and Decay Data Evaluators Network has stated that there is a need for a complete and consistent library of cold- and thermal neutron capture gamma ray and cross-section data (AGM held at Budapest,14-18 October 1996, INDC(NDS)-363); this AGM also recommended the organization of an IAEA CRP on the subject. The International Nuclear Data Committee (INDC) is the primary advisory body to the IAEA Nuclear Data Section on their nuclear data programs. At a biennial meeting in 1997, the INDC strongly recommended that the Nuclear Data Section support new measurements and update the database on Neutron-induced Prompt Gamma-ray Activation Analysis (21st INDC meeting, INDC/P(97)-20). As a consequence of the various recommendations, a CRP on ''Development of a Database for Prompt Gamma-ray Neutron Activation Analysis (PGAA)'' was initiated in 1999. Prior to this project, several consultants had defined the scope, objectives and tasks, as approved subsequently by the IAEA. Each CRP participant assumed responsibility for the execution of specific tasks. The results of their and other research work were discussed and approved by the participants in research co-ordination meetings (see Summary reports: INDC(NDS)-411, 2000; INDC(NDS)-424, 2001; and INDC(NDS)-443, 200). PGAA is a non-destructive radioanalytical method, capable of rapid or simultaneous ''in-situ'' multi-element analyses across the entire Periodic Table, from hydrogen to uranium. However, inaccurate and incomplete data were a significant hindrance in the

  3. Gamma prior distribution selection for Bayesian analysis of failure rate and reliability

    International Nuclear Information System (INIS)

    Waler, R.A.; Johnson, M.M.; Waterman, M.S.; Martz, H.F. Jr.

    1977-01-01

    It is assumed that the phenomenon under study is such that the time-to-failure may be modeled by an exponential distribution with failure-rate parameter, lambda. For Bayesian analyses of the assumed model, the family of gamma distributions provides conjugate prior models for lambda. Thus, an experimenter needs to select a particular gamma model to conduct a Bayesian reliability analysis. The purpose of this paper is to present a methodology which can be used to translate engineering information, experience, and judgment into a choice of a gamma prior distribution. The proposed methodology assumes that the practicing engineer can provide percentile data relating to either the failure rate or the reliability of the phenomenon being investigated. For example, the methodology will select the gamma prior distribution which conveys an engineer's belief that the failure rate, lambda, simultaneously satisfies the probability statements, P(lambda less than 1.0 x 10 -3 ) = 0.50 and P(lambda less than 1.0 x 10 -5 ) = 0.05. That is, two percentiles provided by an engineer are used to determine a gamma prior model which agrees with the specified percentiles. For those engineers who prefer to specify reliability percentiles rather than the failure-rate percentiles illustrated above, one can use the induced negative-log gamma prior distribution which satisfies the probability statements, P(R(t 0 ) less than 0.99) = 0.50 and P(R(t 0 ) less than 0.99999) = 0.95 for some operating time t 0 . Also, the paper includes graphs for selected percentiles which assist an engineer in applying the methodology

  4. Scintigraphic study of palpable breast nodes with 99m Tc-tetrofosmin

    International Nuclear Information System (INIS)

    Pellini, Marcos Pinto; Fonseca, Lea Mirian Barbosa da; Amarante Junior, Jose Luiz de Medeiros; Fabricio, Maria Ines Menescal

    1998-01-01

    In Brazil, breast carcinoma has the greater incidence among women. In 1996, about 31,210 new cases were diagnosed. The purpose of this study is to determine if 99m technetium-tetrofosmin preferentially concentrates within malignant palpable breast nodes, distinguishing them from the benign lumps. Fifth-four consecutive and unsolicited women, mean age 47.5 +- 10.7 years, with palpable nodes in breast, underwent breast scintigraphy with 99m technetium-tetrofosmin and excisional biopsy or fine needle puncture within interval eight weeks. Histopathologic studies demonstrated 13 cysts, 1 cyst with local inflammation, 11 fibroadenoma, 2 fibrodysplasias, 3 fibroadenomas with high cellularity, 1 fibrocystic change with local inflammation, 23 invasive intraductal carcinomas and 1 invasive lobular carcinoma. The nodes ranged from 10 to 100 mm in greater diameter. The scintigraphic study yielded 30 true-negative cases, 24 true-positives, no false-negative and 1 false-positive. This case was a fibrocystic lump with local inflammation. Two patients had metastases in axillary lymph nodes, well detected in scintigraphy. The statistic analysis showed: sensitivity, 100%; specificity, 96.8%; accuracy, 98.2%; negative predictive value, 100%; positive predictive value, 96.0%. Nonparametric tests of Fisher and Chi-square rejected the antithesis at a confidence interval of 99.9% (p 99m technetium-tetrofosmin preferentially concentrates in malignant palpable breast nodes and can help to distinguish them from the benign tumors with with very high accuracy. (author)

  5. Scintigraphic localization of a disseminated malignant pheochromocytoma with the use of 131I-meta-iodobenzylguanidine

    International Nuclear Information System (INIS)

    Troncone, L.; Maini, L.M.; Rufini, V.; Bonifazi, N.; De Rosa, G.; Corsello, S.M.; Mattei, O.

    1984-01-01

    Preliminary clinical studies with 131 I-meta-iodo-benzylguanidine, a newly synthesized radiopharmaceutical and guanethidine analog capable of imaging the adrenal medulla, have led to the identification, of a case of disseminated malignant pheochromocytoma with the localization of brain and bone metastases. The result is of particular interest as the symptomatology in this case appeared rather equivocal and various investigations had led to a completely different diagnosis. This new scintigraphic technique has proved to be safe, specific and noninvasive, and it may have a clinical application as a complementary or alternative technique to conventional diagnostic tests. (orig.)

  6. Neutron induced gamma spectrometry for on-line compositional analysis in coal conversion and fluidized-bed combustion plants

    International Nuclear Information System (INIS)

    Herzenberg, C.L.; O'Fallon, N.M.; Yarlagadda, B.S.; Doering, R.W.; Cohn, C.E.; Porges, K.G.; Duffey, D.

    1977-01-01

    Nuclear techniques involving relatively penetrating radiation may offer the possibility of non-invasive, continuous on-line instrumental monitoring which is representative of the full process stream. Prompt gamma rays following neutron capture are particularly attractive because the penetrating power of the neutrons and the, typically several MeV, capture gammas makes possible interrogation of material within a pipe. We are evaluating neutron capture gamma techniques for this application, both for elemental composition monitoring and for mass-flow measurement purposes, and this paper will present some recent work on composition analysis by neutron induced gamma spectrometry

  7. Statistical analysis for discrimination of prompt gamma ray peak induced by high energy neutron: Monte Carlo simulation study

    International Nuclear Information System (INIS)

    Do-Kun Yoon; Joo-Young Jung; Tae Suk Suh; Seong-Min Han

    2015-01-01

    The purpose of this research is a statistical analysis for discrimination of prompt gamma ray peak induced by the 14.1 MeV neutron particles from spectra using Monte Carlo simulation. For the simulation, the information of 18 detector materials was used to simulate spectra by the neutron capture reaction. The discrimination of nine prompt gamma ray peaks from the simulation of each detector material was performed. We presented the several comparison indexes of energy resolution performance depending on the detector material using the simulation and statistics for the prompt gamma activation analysis. (author)

  8. Scintigraphic demonstration of single- or two-phase gastric emptying in diabetics

    International Nuclear Information System (INIS)

    Eikman, E.A.; Leichter, S.; Waldholtz, B.; Tenorio, L.; Brady, P.

    1989-01-01

    This paper discusses how a modified scintigraphic test of gastric emptying revealed two types of abnormal gastric emptying in diabetic patients. After ingestion of 100 mL of cooked egg whites labeled with 0.5 mCi of Tc-99m sulfur colloid, the geometric mean stomach radioactivity was recorded serially for 90 minutes. Linear regression computed for the log of radioactivity versus time facilitated recognition of changes in gastric emptying. In 16 of 25 consecutive diabetic patients with postprandial symptoms, initial slow emptying (half-life,>100 minutes) was observed. Single-phase emptying was shown in seven of these patients. In nine patients, the slow-emptying phase lasted up to 50 minutes, followed by a distinct second phase of normal or rapid emptying (half-life, <40 minutes). The existence of different gastric emptying implies differing mechanisms of delay and may be important in treatment

  9. VACTIV-DELPHI graphical dialog based program for the analysis of gamma-ray spectra

    International Nuclear Information System (INIS)

    Zlokazov, V.B.

    2002-01-01

    The program VACTIV - Visual ACTIV - has been developed for the analysis of gamma-ray spectra and is a standard graphical dialog based Windows XX application, driven by a menu, mouse and keyboard. On the one hand, it is a conversion of an existing Fortran program ACTIV to the DELPHI-5 language; on the other hand, it is a transformation of the sequential syntax of Fortran programming to a new object-oriented style, based on the organization of event interaction. Since VACTIV is seemingly the first attempt of applying the newest programming languages and styles to systems of spectrum analysis, the goal of its creation was both getting a convenient and efficient technique for data processing, their methods and events. Now the program is widely used for the processing of gamma-ray spectra in experiments on activation analysis

  10. The design of video and remote analysis system for gamma spectrum based on LabVIEW

    International Nuclear Information System (INIS)

    Xu Hongkun; Fang Fang; Chen Wei

    2009-01-01

    For the protection of analyst in the measurement,as well as the facilitation of expert to realize the remote analysis, a solution of live video combined with internet access and control is proposed. DirectShow technology and the LabVIEW'S IDT (Internet Develop Toolkit) module are used, video and analysis pages of the gamma energy spectrum are integrated and published in the windows system by IIS (Internet Information Sever). We realize the analysis of gamma spectrum and remote operations by internet. At the same time, the system has a friendly interface and easily to be put into practice. It also has some reference value for the related radioactive measurement. (authors)

  11. A comparison of semiconductor gamma spectrometric analysis using the peak net area calculations and the whole spectrum processing

    International Nuclear Information System (INIS)

    Krnac, S.; Koskelo, M.; Venkatamaran, R.

    1998-01-01

    This study was conducted to compare the results of gamma spectrometric analysis using the Scaling Confirmatory Factor Analysis (SCFA) method to that of Genie2K, which uses a more traditional method. Gamma ray spectra had had been acquired for several gamma standard sources, all of which except Co-57 and Eu-152 being single gamma ray emitting nuclides. These standard sources spanned the energy range from 60 keV (Am-241) to 1116 keV (Zn-65). The standard sources were counted at 3 different geometries at 3 different geometries, with source-detector distances of 0, 5, and 15 cm. Using single gamma ray spectra collected at a given counting geometry, and the certificate file, an efficiency calibration was created for that geometry. Three different test spectra, one for each counting geometry, had been created by combining several of the standard source spectra. The efficiency calibrations created for the 3 geometries were loaded into the respective spectrum files. Each test spectrum was analyzed using the standard Genie2K engines; Peak locate, Peak search, Interactive peak fit, Background subs-traction, Efficiency correction, and Nuclide Identification with interference analysis. The results of the various calculation steps were reported. In all 3 test cases, the SCFA method identified all the nuclides correctly. The K-40 activities calculated by the SCFA method were reasonably close to that from Genie2K analysis. In general, the quantitative results of the SCFA method were impressive in all 3 cases. On a positive note, the SCFA method did identify low yield gamma lines in Eu-152, which were not identified by the Genie2K analysis. This substantiates claim that the SCFA is more sensitive than the traditional method of spectrum analysis. (authors)

  12. The Einstein@Home Gamma-ray Pulsar Survey. II. Source Selection, Spectral Analysis, and Multiwavelength Follow-up

    Science.gov (United States)

    Wu, J.; Clark, C. J.; Pletsch, H. J.; Guillemot, L.; Johnson, T. J.; Torne, P.; Champion, D. J.; Deneva, J.; Ray, P. S.; Salvetti, D.; Kramer, M.; Aulbert, C.; Beer, C.; Bhattacharyya, B.; Bock, O.; Camilo, F.; Cognard, I.; Cuéllar, A.; Eggenstein, H. B.; Fehrmann, H.; Ferrara, E. C.; Kerr, M.; Machenschalk, B.; Ransom, S. M.; Sanpa-Arsa, S.; Wood, K.

    2018-02-01

    We report on the analysis of 13 gamma-ray pulsars discovered in the Einstein@Home blind search survey using Fermi Large Area Telescope (LAT) Pass 8 data. The 13 new gamma-ray pulsars were discovered by searching 118 unassociated LAT sources from the third LAT source catalog (3FGL), selected using the Gaussian Mixture Model machine-learning algorithm on the basis of their gamma-ray emission properties being suggestive of pulsar magnetospheric emission. The new gamma-ray pulsars have pulse profiles and spectral properties similar to those of previously detected young gamma-ray pulsars. Follow-up radio observations have revealed faint radio pulsations from two of the newly discovered pulsars and enabled us to derive upper limits on the radio emission from the others, demonstrating that they are likely radio-quiet gamma-ray pulsars. We also present results from modeling the gamma-ray pulse profiles and radio profiles, if available, using different geometric emission models of pulsars. The high discovery rate of this survey, despite the increasing difficulty of blind pulsar searches in gamma rays, suggests that new systematic surveys such as presented in this article should be continued when new LAT source catalogs become available.

  13. Gamma-ray sources

    International Nuclear Information System (INIS)

    Hermsen, W.

    1980-01-01

    Results are presented from an analysis of the celestial gamma-ray fine-scale structure based on over half of the data which may ultimately be available from the COS-B satellite. A catalogue consisting of 25 gamma-ray sources measured at energies above 100 MeV is presented. (Auth.)

  14. Preliminary study for pixel identification on a modular gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Soluri, A., E-mail: soluri@isib.cnr.it; Atzeni, G.; Ucci, A.; Cusanno, F.; Massari, R.

    2014-02-01

    Our group has recently investigated and produced new scintigraphic prototypes based on advanced scintillation structure. The aim of this study is to demonstrate the use of scintillation matrices with size equal to the overall area of the Position Sensitive Photomultiplier Tube (PSPMT), to design a modular gamma camera and study the solution of the dead area problems optimizing the overall pixel identification. In this paper we investigate the response of different combinations with crystals integrated within tungsten structure, coupled with H8500, R8900-C12 and R11265-M64 Hamamatsu PSPMTs. Several scintillation matrices, whose dimensions match to the physical area of the PSPMT, have been analysed so that we have also studied limits of detection for the elements of the matrix in the critical zones of the PSPMT, i.e. corners and borders. In order to enhance the detectability of scintillation elements we improved the light collection by depositing metallic layers or treating the tungsten structure with different coating materials, and shaping the external elements of the scintillation matrices. The results have shown good energy resolution and the proposed method can be applied in medical imaging for obtaining high efficiency scintillation devices.

  15. Registered particles onboard identification in the various apertures of GAMMA-400 space gamma-telescope

    Science.gov (United States)

    Arkhangelskaja, Irene

    2016-07-01

    GAMMA-400 (Gamma Astronomical Multifunctional Modular Apparatus) will be the gamma-telescope onboard international satellite gamma-observatory designed for particle registration in the wide energy band. Its parameters are optimized for detection of gamma-quanta with the energy ˜ 100 GeV in the main aperture. The main scientific goals of GAMMA-400 are to investigate fluxes of γ-rays and the electron-positron cosmic ray component possibly generated by dark matter particles decay or annihilation and to search for and study in detail discrete γ-ray sources, to investigate the energy spectra of Galactic and extragalactic diffuse γ-rays, and to study γ-ray bursts and γ-emission from the active Sun. This article presents analysis of detected events identification procedures and energy resolution in three apertures provide particles registration both from upper and lateral directions based on GAMMA-400 modeling due special designed software. Time and segmentation methods are used to reject backsplash (backscattering particles created when high energy γ-rays interact with the calorimeter's matter and move in the opposite direction) in the main aperture while only energy deposition analysis allows to reject this effect in the additional and lateral ones. The main aperture provides the best angular (all strip layers information analysis) and energy (energy deposition in the all detectors studying) resolution in the energy range 0.1 - 3 × 10^{3} GeV. The energy resolution in this band is 1%. Triggers in the main aperture will be formed using information about particle direction provided by time of flight system and presence of charged particle or backsplash signal formed according to analysis of energy deposition in combination of all two-layers anticoincidence systems individual detectors. In the additional aperture gamma-telescope allows to register events in the energy band 10 × 10^{-3} - 3 × 10^{3} GeV. The additional aperture energy resolution provides due to

  16. ESCL8R and LEVIT8R: interactive graphical analysis of {gamma}-{gamma} and {gamma}-{gamma}-{gamma} coincidence data for level schemes

    Energy Technology Data Exchange (ETDEWEB)

    Radford, D C [Atomic Energy of Canada Ltd., Chalk River, ON (Canada). Chalk River Nuclear Labs.

    1992-08-01

    The extraction of complete and consistent nuclear level schemes from high-fold coincidence data will require intelligent computer programs. These will need to present the relevant data in an easily assimilated manner, keep track of all {gamma}-ray assignments and expected coincidence intensities, and quickly find significant discrepancies between a proposed level scheme and the data. Some steps in this direction have been made at Chalk River. The programs ESCL8R and LEVIT8R, for analysis of two-fold and three-fold data sets respectively, allow fast and easy inspection of the data, and compare the results to expectations calculations on the basis of a proposed level scheme. Least-squares fits directly to the 2D and/or 3D data, with the intensities and energies of the level scheme transitions as parameters, allow fast and easy extraction of the optimum physics results. (author). 4 refs., 3 figs.

  17. A new code for spectrometric analysis for environmental radiological surveillance on monitors focused on gamma radioactivity on aerosols

    Energy Technology Data Exchange (ETDEWEB)

    De Blas, Alfredo; Tapia, Carlos; Riego, Albert; Garcia, Roger; Dies, Javier; Diaz, Pedro [Nuclear Engineering Research Group, Departament of Physics and Nuclear Engineering, Technical University of Catalonia, Barcelona (Spain); Toral, Juan [Raditel Serveis, Tarragona (Spain); Batalla, Enric [Radiological Activities Corrdination Service - SCAR, Generalitat de Catalunya. Barcelona (Spain)

    2015-07-01

    pGamma is a code developed by the NERG group of the Technical University of Catalonia - Barcelona Tech for the analysis of gamma spectra generated by the Equipment for the Continuous Measurement and Identification of Gamma Radioactivity on Aerosols with Paper Filter developed for our group and Raditel Servies company. Nowadays the code is in the process of adaptation for the monitors of the Environmental Radiological Surveillance Network of the Local Government of Catalonia (Generalitat of Catalonia), Spain. The code is a Spectrum Analysis System, it identifies the gamma emitters on the spectrum, determines its Concentration of Activity, generates alarms depending on the Activity of the emitters and generates a report. The Spectrum Analysis System includes a library with emitters of interest, NORM and artificial. The code is being used on the three stations with the aerosol monitor of the Network (Asco and Vandellos, near both Nuclear Power Plants and Barcelona). (authors)

  18. Reduction of Compton background from hydrogen in prompt gamma-ray analysis by multiple photon detection

    International Nuclear Information System (INIS)

    Toh, Y.; Oshima, M.; Kimura, A.; Koizumi, M.; Furutaka, K.; Hatsukawa, Y.

    2008-01-01

    Low-energy photons produced by the Compton scattering from hydrogen increase the background in the lower-energy region of the gamma-ray spectrum. This results in an increase in the detection limit for trace elements. In multiple photon detection prompt gamma-ray analysis (MPGA), only those elements that simultaneously emit two or more prompt gamma-rays, which have cascade relation and are emitted within a short interval, can be measured. Therefore, the influence of hydrogen can be reduced. In this study, standard polymer and food samples are measured. The hydrogen background is reduced in MPGA. (author)

  19. Gamma prior distribution selection for Bayesian analysis of failure rate and reliability

    International Nuclear Information System (INIS)

    Waller, R.A.; Johnson, M.M.; Waterman, M.S.; Martz, H.F. Jr.

    1976-07-01

    It is assumed that the phenomenon under study is such that the time-to-failure may be modeled by an exponential distribution with failure rate lambda. For Bayesian analyses of the assumed model, the family of gamma distributions provides conjugate prior models for lambda. Thus, an experimenter needs to select a particular gamma model to conduct a Bayesian reliability analysis. The purpose of this report is to present a methodology that can be used to translate engineering information, experience, and judgment into a choice of a gamma prior distribution. The proposed methodology assumes that the practicing engineer can provide percentile data relating to either the failure rate or the reliability of the phenomenon being investigated. For example, the methodology will select the gamma prior distribution which conveys an engineer's belief that the failure rate lambda simultaneously satisfies the probability statements, P(lambda less than 1.0 x 10 -3 ) equals 0.50 and P(lambda less than 1.0 x 10 -5 ) equals 0.05. That is, two percentiles provided by an engineer are used to determine a gamma prior model which agrees with the specified percentiles. For those engineers who prefer to specify reliability percentiles rather than the failure rate percentiles illustrated above, it is possible to use the induced negative-log gamma prior distribution which satisfies the probability statements, P(R(t 0 ) less than 0.99) equals 0.50 and P(R(t 0 ) less than 0.99999) equals 0.95, for some operating time t 0 . The report also includes graphs for selected percentiles which assist an engineer in applying the procedure. 28 figures, 16 tables

  20. Analysis of plutonium gamma-ray spectra by small portable computers

    International Nuclear Information System (INIS)

    Ruhter, W.; Gunnink, R.; Camp, D.; DeCarolis, M.

    1985-01-01

    A sophisticated program for isotopic analysis of plutonium gamma-ray spectra using small computers has been developed. It is implemented on a DEC LSI-11/2 configured in a portable unit without a mass storage device for use by IAEA inspectors in the field. Only the positions of the 148-keV 241 Pu and 208-keV 237 U peaks are needed as input. Analysis is completed in 90 seconds by fitting isotopic component response functions to peak multiplets. 9 refs., 2 figs., 1 tab

  1. Whole-body and pinhole bone scintigraphic manifestations of Reiter`s syndrome: distribution patterns and early and characteristic signs

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-Hoon; Chung, Soo-Kyo; Park, Young-Ha; Lee, Sung-Yong; Sohn, Hyung-Sun [Department of Nuclear Medicine, Catholic University Hospitals, Seoul (Korea, Republic of); Bahk, Yong-Whee [Department of Radiology, Samsung Cheil Hospital, Sungkyunkwan University College of Medicine, Seoul (Korea, Republic of)

    1999-02-01

    The characteristic whole-body and pinhole scintigraphic manifestations of osteo-enthesopathy and arthropathy in Reiter`s syndrome (RS) are described, with an emphasis on early diagnosis. We analysed 59 sets of whole-body and pinhole bone scintigrams of 59 patients with RS. The population comprised 47 men and 12 women with an age range from 15 to 53 years (mean=29.4). Bone scintigraphy was carried out 2-2.5 h after intravenous injection of technetium-99m hydroxydiphosphonate using a single-head gamma camera (Siemens Orbiter Model 6601) with a low-energy high-resolution and a 4-mm pinhole collimator for whole-body and pinhole scintigraphy, respectively. In total 262 lesions of osteo-enthesopathy and arthritis were detected on 59 whole-body scintigrams, an incidence of 4.4 lesions per patient. As anticipated, the lesional distribution was asymmetrical: 68% were in the lower limb skeleton and 32% in the axial and upper limb skeleton. Pinhole bone scintigraphy, applied selectively to one region of interest in each case, enabled us to accurately diagnose arthritis and osteo-enthesopathy. It was noteworthy that osteo-enthesopathy, alone or in combination with arthritis, occurred in 78.9%, and had a strong predilection for the foot bones, especially the calcaneus (25.6%). Pinhole scintigraphy detected enthesopathy in the absence of radiographic alteration in 14.1% of cases and portrayed characteristic signs of RS in 6.9%. Whole-body bone scintigraphy augmented with pinhole scintigraphy was found to be useful in order to panoramically display the systemic involvement pattern, to assess the characteristic bone and articular alterations and to detect early signs of RS. (orig.) With 10 figs., 3 tabs., 19 refs.

  2. A study of Venus surface elemental composition from 14 MeV neutron induced gamma ray spectroscopy: Activation analysis

    International Nuclear Information System (INIS)

    Jun, I.; Kim, W.; Smith, M.; Mitrofanov, I.; Litvak, M.

    2011-01-01

    The surface elemental composition of Venus can be determined using an artificially pulsed 14 MeV neutron generator (PNG) combined with a gamma ray spectrometer (GRS). The 14 MeV neutrons will interact with the surface materials and generate gamma rays, characteristic of specific elements, whose energy spectrum will be measured by GRS. These characteristic gamma rays are produced mainly through 3 different neutron interaction mechanisms: capture, inelastic, and activation reactions. Each reaction type has a different neutron energy dependency and different time scale for gamma ray production and transport. Certain elements are more easily identified through one reaction type over the others. Thus, careful analysis of the gamma ray spectra during and after the neutron pulse provides a comprehensive understanding of the surface elemental composition. In this paper, we use a well-tested neutron/gamma transport code, called Monte Carlo N-Particles (MCNP), to investigate the measurement capability of a PNG-GRS detection system through the neutron activation reactions. An activation analysis was performed for a representative soil composition of Venus with a notional operational scenario of PNG and GRS. The analysis shows that the proposed instrument concept can identify most of the modeled surface elements at Venus with sufficient accuracy through the activation mode. Specifically, U, Th, K, Si can be measured to within 1%, Fe within 2%, Al within 10%, Ca within 5%, Mg with 15%, Mn with 20%, and Cl within 6%. Although modeled in the analysis, it is shown that the activation mode alone cannot distinguish the S and Ti peaks.

  3. Modern utilization of accurate methods for gamma-ray spectral analysis detected by high pure germanium (HPGE) detectors through different applications

    International Nuclear Information System (INIS)

    El-Sayed, M.M.

    2005-01-01

    this thesis presents a novel way for application of wavelet trans-from theory in gamma -ray spectroscopy. this technique was applied for searching real and weak peaks, solving problem of multiplets, smoothing and de-noising gamma-ray spectra, and using artificial neural network for identifying peaks. a brief description about gamma-ray spectrum analysis is presented . we discussed the necessary formulas and algorithms of wavelet theory to solve these main problems in gamma ray spectrum analysis. the algorithm of peak search was applied on different types of spectra, IAEA spectra and other sources of gamma spectra. the algorithm of multiplets algorithm was applied successfully on different types of multiplets. the algorithm of denoising was applied successfully on different sources of spectra

  4. Integration of auto analysis program of gamma spectrum and software and determination of element content in sample by k-zero method

    International Nuclear Information System (INIS)

    Trinh Quang Vinh; Truong Thi Hong Loan; Mai Van Nhon; Huynh Truc Phuong

    2014-01-01

    Integrating the gamma spectrum auto-analysis program with elemental analysis software by k-zero method is the objective for many researchers. This work is the first stepin building an auto analysis program of gamma spectrum, which includes modules of reading spectrum, displaying spectrum, calibrating energy of peak, smoothing spectrum, calculating peak area and determining content of elements in sample. Then, the results from the measurements of standard samples by a low level spectrometer using HPGe detector are compared to those of other gamma spectrum auto-analysis programs. (author)

  5. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    International Nuclear Information System (INIS)

    Hausmann, T.; Mueller-Schauenburg, W.; Goeke, M.; Luebeck, M.; Gratz, K.F.; Meier, P.; Manns, M.; Hundeshagen, H.

    1995-01-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  6. Scintigraphic test of gastric emptying and motility: preliminary results in patients with chronic gastritis

    Energy Technology Data Exchange (ETDEWEB)

    Hausmann, T. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Mueller-Schauenburg, W. [Abt. Nuklearmedizin, Univ. Tuebingen (Germany); Goeke, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Luebeck, M. [Abt. Nuklearmedizin, Univ.-Krankenhaus Eppendorf, Hamburg (Germany); Gratz, K.F. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany); Meier, P. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Manns, M. [Abt. Gastroenterologie und Hepatologie, Medizinische Hochschule Hannover (Germany); Hundeshagen, H. [Abt. Nuklearmedizin und Spezielle Biophysik, Medizinische Hochschule Hannover (Germany)

    1995-11-01

    To record gastric peristalsis using a conventional scintigraphic gastric emptying test the frame rate was increased to 1 frame per 3 s at 10, 30, and 50 min postprandially. The gastric contraction frequency was obtained from the first harmonic of a Fourier transform of a gastric region of interest (ROI) curve. The propagation of gastric contractions was better revealed from computed functional images of the phase and amplitude distribution as compared with the multiple scintigraphic images. The maximal count-rate changes per pixel were calculated as an estimate of the most prominent regional contractile activity of the gastric wall. Among 12 patients with chronic gastritis the group with more severe dyspeptic complaints (n = 6) had significantly higher count-rate changes per pixel when compared with the group with minor complaints (20.0, 21.1 and 14.2 vs 12.9, 12.0, and 10.4 counts/pixel X s at 10, 30, and 50 min. respectively; p < 0.05). The mean half-times of gastric emptying (61, SD 11 vs 54, SD 13 min) and the mean gastric contraction frequencies (2.99, SD 0.19; 3.09, SD 0.33; 3.07, SD 0.10 vs 3.15, SD 0.15; 3.17, SD 0.13; 3.23, SD 0.20 cycles/min at 10, 30, and 50 min, respectively) did not show significant differences between both groups. Our preliminary results agree with the hypothesis of the occurrence of more powerful, nonexpulsive gastric-wall contractions in patients with more severe dyspeptic complaints. Hence, additional quantification of gastric motility allowed a more detailed evaluation of gastric-motor-activity disorders that were for so long not accessible to conventional gastric-emptying tests. (orig.)

  7. Scintigraphic and Endoscopic Evaluation of Radiation-induced Acute Gastrointestinal Syndrome in Micro-pig Model

    International Nuclear Information System (INIS)

    Lee, Seung-Sook; Kim, Kyung-Min; Kim, Jin; Jang, Won-Suk; Lee, Jung-Eun; Kim, Noo-Ri; Lee, Sun-Joo; Kim, Mi-Sook; Ji, Young-Hoon; Cheon, Gi-Jeong; Lim, Sang-Moo

    2007-01-01

    Micro-pig model can be served as a proper substitute for humans in studying acute radiation syndrome following radiation-exposure accidents, especially showing similar clinico-pathologic response of hematopoietic and gastrointestinal (GI) syndrome to human. Among acute GI syndrome induced by radiation, GI motility disturbance has not been studied, however, it would be important in a viewpoint of affecting infectious progression from GI tract. Here, we employed scintigraphy of GI transit time and sequential endoscopic examination and tissue sampling in micropigs followed by abdominal radiation exposure. The specific aims of this study are to evaluate objective evidence of GI motility disturbance by scintigraphic evaluation and to find corresponding clinicoapthologic changes in radiation-induced acute GI syndrome

  8. ANALYSIS OF GAMMA HEATING AT TRIGA MARK REACTOR CORE BANDUNG USING PLATE TYPE FUEL

    Directory of Open Access Journals (Sweden)

    Setiyanto Setiyanto

    2016-10-01

    Full Text Available ABSTRACT In accordance with the discontinuation of TRIGA fuel element production by its producer, the operation of all TRIGA type reactor of at all over the word will be disturbed, as well as TRIGA reactor in Bandung. In order to support the continuous operation of Bandung TRIGA reactor, a study on utilization of fuel plate mode, as used at RSG-GAS reactor, to replace the cylindrical model has been done. Various assessments have been done, including core design calculation and its safety aspects. Based on the neutronic calculation, utilization of fuel plate shows that Bandung TRIGA reactor can be operated by 20 fuel elements only. Compared with the original core, the new reactor core configuration is smaller and it results in some empty space that can be used for in-core irradiation facilities. Due to the existing of in-core irradiation facilities, the gamma heating value became a new factor that should be evaluated for safety analysis. For this reason, the gamma heating for TRIGA Bandung reactor using fuel plate was calculated by Gamset computer code. The calculations based on linear attenuation equations, line sources and gamma propagation on space. Calculations were also done for reflector positions (Lazy Susan irradiation facilities and central irradiation position (CIP, especially for any material samples. The calculation results show that gamma heating for CIP is significantly important (0,87 W/g, but very low value for Lazy Susan position (lest then 0,11 W/g. Based on this results, it can be concluded that the utilization of CIP as irradiation facilities need to consider of gamma heating as data for safety analysis report. Keywords: gamma heating, nuclear reactor, research reactor, reactor safety.   ABSTRAK Dengan dihentikannya produksi elemen bakar reaktor jenis Triga oleh produsen, maka semua reaktor TRIGA di dunia terganggu operasinya, termasuk juga reaktor TRIGA 2000 di Bandung. Untuk mendukung pengoperasian reaktor TRIGA Bandung

  9. Consequences of the factorization hypothesis in nucleon-nucleon, $\\gamma p and \\gamma \\gamma$ scattering

    CERN Document Server

    Block, Martin M

    2002-01-01

    Using an eikonal structure for the scattering amplitude, factorization theorems for nucleon-nucleon, gamma p and gamma gamma scattering at high energies have been derived, using only some very general assumptions. Using a QCD-inspired eikonal analysis of nucleon-nucleon scattering, we present here experimental confirmation for factorization of cross sections, nuclear slope parameters B and rho -values (ratio of real to imaginary portion of forward scattering amplitudes), showing that: 1) the three factorization theorems of Block and Kaidalov [2000] hold, 2) the additive quark model holds to approximately=1%, and 3) vector dominance holds to better than approximately=4%. Predictions for the total cross section, elastic cross section and other forward scattering parameters at the LHC (14 TeV) are given. (12 refs).

  10. The Prompt Gamma Neutron Activation Analysis Facility at ICN-Pitesti

    International Nuclear Information System (INIS)

    Barbos, D.; Paunoiu, C.; Mladin, M.; Cosma, C.

    2008-01-01

    PGNAA is a very widely applicable technique for determining the presence and amount of many elements simultaneously in samples ranging in size from micrograms to many grams. PGNAA is characterized by its capability for nondestructive multi-elemental analysis and its ability to analyse elements that cannot be determined by INAA. By means of this PGNAA method we are able to increase the performance of INAA method. A facility has been developed at Institute for Nuclear Research-Pitesti so that the unique features of prompt gamma-ray neutron activation analysis can be used to measure trace and major elements in samples. The facility is linked at the radial neutron beam tube at ACPR-TRIGA reactor. During the PGNAA-facility is in use the ACPR reactor will be operated in steady-state mode at 250 KW maximum power. The facility consists of a radial beam-port, external sample position with shielding, and induced prompt gamma-ray counting system.Thermal neutron flux with energy lower than cadmium cut-off at the sample position was measured using thin gold foil is: φ scd = 1.10 6 n/cm 2 /s with a cadmium ratio of:80.The gamma-ray detection system consist of an HpGe detector of 16% efficiency (detector model GC1518) with 1.85 keV resolution capability. The HpGe is mounted with its axis at 90 deg. with respect to the incident neutron beam at distance about 200mm from the sample position. To establish the performance capabilities of the facility, irradiation of pure element or sample compound standards were performed to identify the gama-ray energies from each element and their count rates

  11. Exclusive production of pion pairs in {gamma}*{gamma} collisions at Large Q{sup 2}

    Energy Technology Data Exchange (ETDEWEB)

    Diehl, M.

    2000-03-15

    The authors perform a QCD analysis of the exclusive production of two mesons in {gamma}*{gamma} collisions in the kinematical domain of large photon virtuality Q and small hadronic invariant mass W. This reaction is dominated by a scale invariant mechanism which factorizes into a perturbative subprocess, {gamma}*{gamma} {r{underscore}arrow} q{anti q} or {gamma}*{gamma} {r{underscore}arrow} gg, and a generalized two-meson distribution amplitude. The authors develop in detail the phenomenology of this process at e{sup +}e{sup {minus}} colliders. Using a simple model for the two-pion distribution amplitude, based on its general properties, the authors estimate the cross section for the kinematics accessible at BABAR, BELLE, CLEO and LEP.

  12. Bone scintigraphy in bone stress. A technical consideration and correlation of the findings to clinical symptoms especially to the pain

    International Nuclear Information System (INIS)

    Kuusela, T.; Vorne, M.; Vahatalo, S.

    1983-01-01

    The purpose of this investigation was to find out a reliable scintigraphic method to investigate different fatigue phenomena in bone and to correlate the scintigraphic findings to the development of clinical symptoms. The gamma-imaging after the injection of bone seeking tracers is recommended to be performed after a period of 1-3 hours. The experiments indicate that in active bone tissue, might it be a healing fracture or a remodeling bone, the tracer uptake still increases after 1-3 hours. The delayed gamma-imaging can therefore be useful, especially if it is important to investigate faint physiological changes in bone tissue. It seems, that the capacity of emission energy in the diagnosis of bone affections is superior to the radiology because of its excellent histo-functional resolution especially in detecting and localizing bone affections

  13. Reference peak method for analysis of doublets in gamma-ray spectrometry used in neutron activation analysis

    International Nuclear Information System (INIS)

    Wasek, M.; Cichowlas, A.; Sterlinski, S.; Dybczynski, R.

    2000-01-01

    A simple algebraic method for the quantitative analysis of doublets in gamma-ray spectra from HPGe detectors is presented. The calculation algorithm is accomplished using the Microsoft Excel program. The method does not require any assumptions regarding the shape of the peaks in the spectrum. The possibilities of quantitative analysis of doublets of various intensity ration and separation of ots components are discussed in detail. The practical examples proved the usefulness the method also for the analysis of the closed doublets. (author)

  14. Computer processing of the scintigraphic image using digital filtering techniques

    International Nuclear Information System (INIS)

    Matsuo, Michimasa

    1976-01-01

    The theory of digital filtering was studied as a method for the computer processing of scintigraphic images. The characteristics and design techniques of finite impulse response (FIR) digital filters with linear phases were examined using the z-transform. The conventional data processing method, smoothing, could be recognized as one kind of linear phase FIR low-pass digital filtering. Ten representatives of FIR low-pass digital filters with various cut-off frequencies were scrutinized from the frequency domain in one-dimension and two-dimensions. These filters were applied to phantom studies with cold targets, using a Scinticamera-Minicomputer on-line System. These studies revealed that the resultant images had a direct connection with the magnitude response of the filter, that is, they could be estimated fairly well from the frequency response of the digital filter used. The filter, which was estimated from phantom studies as optimal for liver scintigrams using 198 Au-colloid, was successfully applied in clinical use for detecting true cold lesions and, at the same time, for eliminating spurious images. (J.P.N.)

  15. Scintigraphic detection of metastatic melanoma using indium 111/DTPA conjugated anti-gp240 antibody (ZME-018)

    International Nuclear Information System (INIS)

    Kirkwood, J.M.; Neumann, R.D.; Zoghbi, S.S.; Ernstoff, M.S.; Cornelius, E.A.; Shaw, C.; Ziyadeh, T.; Fine, J.A.; Unger, M.W.

    1987-01-01

    We evaluated the toxicity, pharmacokinetics, and localization of a monoclonal IgG2 alpha murine anti-human melanoma (gp240) antibody (ZME-018) that recognizes a tumor-associated cell surface glycoprotein of 240,000 molecular weight present in most melanomas. The antibody was conjugated with DTPA (diethylenetriamine pentaacetic acid) and labeled by chelation of 111 In. One mg of antibody labeled with 5 mCi of 111 In was infused, together with 0 to 40 mg of cold carrier ZME-018. The blood clearance, urinary excretion, and in vivo localization were determined in 26 patients. Scintigraphic images were obtained at 24 hours and 72 hours in all patients. Mild toxicity occurred in one patient. The half-time clearance of labeled monoclonal murine antibody (MoAb) from the blood increased from 16.1 hours at an antibody dose of 1 mg to 35.9 hours at 40 mg. Males showed faster clearance from the blood than did females or a single castrated male, perhaps due to selective concentration of antibody in the testes. Nonspecific uptake in liver, spleen, bone marrow, and intestine was seen in all patients. The percentage of known metastatic foci detected increased with the total dosage of antibody, from 23% at doses less than or equal to 5 mg, to 65%, 87% and 78% for 10, 20, and 40 mg, respectively. We conclude that at doses of greater than or equal to 10 mg, ZME-018 is a safe and potentially useful agent for the scintigraphic detection of metastatic malignant melanoma

  16. Automation of a gamma spectrometric analysis method for naturally occuring radionuclides in different materials (NORM)

    International Nuclear Information System (INIS)

    Marzocchi, Olaf

    2009-06-01

    This work presents an improvement over the standard analysis routine used in the Physikalisches Messlabor to detect gamma peaks in spectra from naturally occurring radioactive materials (NORM). The new routine introduces the use of custom libraries of known gamma peaks, in order to ease the work of the software than can therefore detect more peaks. As final result, the user performing the analysis has less chances of making errors and can also analyse more spectra in the same amount of time. A new software, with an optimised interface able to further enhance the productivity of the user, is developed and validated. (orig.)

  17. On the maximum and minimum of two modified Gamma-Gamma variates with applications

    KAUST Repository

    Al-Quwaiee, Hessa; Ansari, Imran Shafique; Alouini, Mohamed-Slim

    2014-01-01

    on these new results to present the performance analysis of (i) a dual-branch free-space optical selection combining diversity undergoing independent but not necessarily identically distributed Gamma-Gamma fading under the impact of pointing errors and of (ii

  18. Analysis and databasing software for integrated tomographic gamma scanner (TGS) and passive-active neutron (PAN) assay systems

    International Nuclear Information System (INIS)

    Estep, R.J.; Melton, S.G.; Buenafe, C.

    2000-01-01

    The CTEN-FIT program, written for Windows 9x/NT in C++,performs databasing and analysis of combined thermal/epithermal neutron (CTEN) passive and active neutron assay data and integrates that with isotopics results and gamma-ray data from methods such as tomographic gamma scanning (TGS). The binary database is reflected in a companion Excel database that allows extensive customization via Visual Basic for Applications macros. Automated analysis options make the analysis of the data transparent to the assay system operator. Various record browsers and information displays simplify record keeping tasks

  19. A Comparative Analysis of Uranium Ore using Laser Fluorimetric and gamma Spectrometry Techniques

    International Nuclear Information System (INIS)

    Madbouly, M.; Nassef, M. H.; El-Mongy, S.A.; Diab, A.M.

    2009-01-01

    A developed chemical separation method was used for the analysis of uranium in a standard U-ore (IAEA-RGU-1) by LASER fluorimetric technique. The non-destructive gamma assay technique was also applied to verify and compare the uranium content analyzed using laser technique. The results of the uranium analysis obtained by laser fluorimetry were found to be in the range of 360 - 420 μg/g with an average value of 390 μg/g. The bias between the measured and the certified value does not exceed 9.9%. For gamma-ray spectrometric analysis, the results of the measured uranium content were found to be in the range of 393.8 - 399.4 μg/g with an average value of 396.3 μg/g. The % difference in the case of γ- assay was 1.6 %. In general, the methods of analysis used in this study are applicable for a precise determination of uranium. It can be concluded that, laser analysis is preferred for assay of uranium ore due to the required small sample weight, the low time of sample preparation and cost of analysis.

  20. Methods for the analysis of overlapped peaks in analytical gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Sterlinski, S.; Wasek, M.

    1989-01-01

    A review of critical evaluation of simple methods for the analysis of overlapped peaks from the point of view of their applicability in activation analysis are described. These methods are adopted from other spectroscopic techniques and gas chromatography. The experimental verification has been carried out for gamma-ray spectra in the energy range 120 KeV - 3 MeV. 28 refs., 8 figs., 3 tabs. (author)

  1. Database of prompt gamma rays from slow neutron capture forelemental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Firestone, R.B.; Choi, H.D.; Lindstrom, R.M.; Molnar, G.L.; Mughabghab, S.F.; Paviotti-Corcuera, R.; Revay, Zs; Trkov, A.; Zhou,C.M.; Zerkin, V.

    2004-12-31

    The increasing importance of Prompt Gamma-ray ActivationAnalysis (PGAA) in a broad range of applications is evident, and has beenemphasized at many meetings related to this topic (e.g., TechnicalConsultants' Meeting, Use of neutron beams for low- andmedium-fluxresearch reactors: radiography and materialscharacterizations, IAEA Vienna, 4-7 May 1993, IAEA-TECDOC-837, 1993).Furthermore, an Advisory Group Meeting (AGM) for the Coordination of theNuclear Structure and Decay Data Evaluators Network has stated that thereis a need for a complete and consistent library of cold- and thermalneutron capture gammaray and cross-section data (AGM held at Budapest,14-18 October 1996, INDC(NDS)-363); this AGM also recommended theorganization of an IAEA CRP on the subject. The International NuclearData Committee (INDC) is the primary advisory body to the IAEA NuclearData Section on their nuclear data programmes. At a biennial meeting in1997, the INDC strongly recommended that the Nuclear Data Section supportnew measurements andupdate the database on Neutron-induced PromptGamma-ray Activation Analysis (21st INDC meeting, INDC/P(97)-20). As aconsequence of the various recommendations, a CRP on "Development of aDatabase for Prompt Gamma-ray Neutron Activation Analysis (PGAA)" wasinitiated in 1999. Prior to this project, several consultants had definedthe scope, objectives and tasks, as approved subsequently by the IAEA.Each CRP participant assumed responsibility for the execution of specifictasks. The results of their and other research work were discussed andapproved by the participants in research co-ordination meetings (seeSummary reports: INDC(NDS)-411, 2000; INDC(NDS)-424, 2001; andINDC(NDS)-443, 200). PGAA is a non-destructive radioanalytical method,capable of rapid or simultaneous "in-situ" multi-element analyses acrossthe entire Periodic Table, from hydrogen to uranium. However, inaccurateand incomplete data were a significant hindrance in the qualitative andquantitative

  2. Analysis of gamma heating at TRIGA mark reactor core Bandung using plate type fuel

    International Nuclear Information System (INIS)

    Setiyanto; Tukiran Surbakti

    2016-01-01

    In accordance with the discontinuation of TRIGA fuel element production by its producer, the operation of all TRIGA type reactor of at all over the word will be disturbed, as well as TRIGA reactor in Bandung. In order to support the continuous operation of Bandung TRIGA reactor, a study on utilization of fuel plate mode, as used at RSG-GAS reactor, to replace the cylindrical model has been done. Various assessments have been done, including core design calculation and its safety aspects. Based on the neutronic calculation, utilization of fuel plate shows that Bandung TRIGA reactor can be operated by 20 fuel elements only. Compared with the original core, the new reactor core configuration is smaller and it results in some empty space that can be used for in-core irradiation facilities. Due to the existing of in-core irradiation facilities, the gamma heating value became a new factor that should be evaluated for safety analysis. For this reason, the gamma heating for TRIGA Bandung reactor using fuel plate was calculated by Gamset computer code. The calculations based on linear attenuation equations, line sources and gamma propagation on space. Calculations were also done for reflector positions (Lazy Susan irradiation facilities) and central irradiation position (CIP), especially for any material samples. The calculation results show that gamma heating for CIP is significantly important (0.87 W/g), but very low value for Lazy Susan position (lest then 0.11 W/g). Based on this results, it can be concluded that the utilization of CIP as irradiation facilities need to consider of gamma heating as data for safety analysis report. (author)

  3. Novel CT and scintigraphic findings of bone metastasis from invasive lobular breast cancer.

    Science.gov (United States)

    Al-Ogaili, Zeyad; Troedson, Russell

    2016-02-01

    The aim of this study is to identify and describe the computed tomography and scintigraphic imaging patterns of osseous metastasis from invasive lobular breast cancer (ILC). CT and skeletal scintigraphy (SS) studies of 23 patients with diagnosis of ILC and osseous metastasis on their initial presentation were reviewed. Osseous metastases in 14 patients (60.8%) appear as uniform small sclerotic lesions (USSL) on CT scan. The SS in these patients were interpreted as negative for metastasis (either normal or with some equivocal findings not typical for metastasis). Osseous metastasis from ILC can have a characteristic imaging pattern on CT and SS. The pattern of USSL on CT scan with negative SS is highly suggestive of osseous metastasis from ILC. © 2015 The Royal Australian and New Zealand College of Radiologists.

  4. Scintigraphic localization of pheochromocytomas using 131 I-meta-iodobenzylguanidine. Comparison with computerized tomography

    International Nuclear Information System (INIS)

    Charbonnel, B.; Coornaert, S.; Tellier, J.L.; Peltier, P.; Chatal, J.F.

    1984-01-01

    Meta-iodobenzylguanidine was synthesized, radiolabelled with I 131 or I 123 and injected to 28 controls and 7 patients totalizing 13 foci of pheochromocytoma. The tumour was located in one adrenal gland in 3 cases, in both adrenal glands in 1 case, and between the aorta and the vena cava in 1 case; 2 were malignant with metastases. Scintigraphy was negative in all controls, whereas all pheochromocytomas were clearly demonstrated 24 h after injection, except one regarded as non functional due to necrosis. By comparison, CT readily showed the tumour in 7 cases, showed it only thanks to scintigraphic guidance in 4 cases and failed in 2 cases. It is concluded that scintigraphy with meta-iodo-benzylguanidine provides a safe and reliable means of locating a wide range of pheochromocytomas [fr

  5. Hepatic handling of a synthetic gamma-labeled bile acid (75SeHCAT)

    International Nuclear Information System (INIS)

    Galatola, G.; Jazrawi, R.P.; Bridges, C.; Joseph, A.E.; Northfield, T.C.

    1988-01-01

    75 Se-homocholic acid-taurine ( 75 SeHCAT) is the first available gamma-labeled bile acid, and should therefore be handled more efficiently and specifically by the liver than previous hepatoscintigraphic agents. We have measured serum and hepatic kinetics for 75 SeHCAT, and compared them with those for the conventional hepatobiliary scintigraphic agent 99mTc-hepatoiminodiacetic acid, and with serum kinetics for the corresponding natural bile acid, [ 14 C]cholic acid-taurine. We used a dynamic scintigraphic technique and serial blood sampling in 8 subjects. Initial hepatic uptake rate was identical to initial serum disappearance rate (14% dose/min) for 75 SeHCAT, but significantly lower for 99mTc-hepatoiminodiacetic acid (6% vs. 14% dose/min, p less than 0.001). Hepatic transit time was shorter for 75 SeHCAT (13 min vs. 22 min, p less than 0.02), net hepatic excretory rate was more rapid (1.4% vs. 0.8% dose/min, p less than 0.001), and urinary excretion was lower (1.0% vs. 9.0% dose, p less than 0.001). Initial and late-plasma disappearance rates were significantly lower for 75 SeHCAT (14.3% and 1.5% dose/min) than for [ 14 C]cholic acid-taurine (21.3% and 2.8% dose/min, respectively), and plasma clearance was also lower (2 75 vs. 670 ml/min). In vitro, 75 SeHCAT was bound to serum proteins more completely than [ 14 C]cholic acid-taurine (90.4% vs. 86.5%, p less than 0.005). We conclude that 75 SeHCAT provides a hepatoscintigraphic agent that is handled more efficiently and specifically by the liver than the conventionally used agent 99mTc-hepatoiminodiacetic acid. It is not cleared from the serum as rapidly as [ 14 C]cholic acid-taurine, probably due to its stronger protein binding. The clinical value of 75 SeHCAT in assessing liver disease should be investigated

  6. On the maximum and minimum of two modified Gamma-Gamma variates with applications

    KAUST Repository

    Al-Quwaiee, Hessa

    2014-04-01

    In this work, we derive the statistical characteristics of the maximum and the minimum of two modified1 Gamma-Gamma variates in closed-form in terms of Meijer\\'s G-function and the extended generalized bivariate Meijer\\'s G-function. Then, we rely on these new results to present the performance analysis of (i) a dual-branch free-space optical selection combining diversity undergoing independent but not necessarily identically distributed Gamma-Gamma fading under the impact of pointing errors and of (ii) a dual-hop free-space optical relay transmission system. Computer-based Monte-Carlo simulations verify our new analytical results.

  7. Biological evaluation of 99mTc-Voriconazole as a potential agent for diagnosis of fungal infections by gamma scintigraphy

    International Nuclear Information System (INIS)

    Reyes, Laura; Martinez, Elena; Giglio, Javier; Teran, Mariella

    2011-01-01

    The spread of HIV has led to an increase of fungal infections such as candidiasis and invasive aspergillosis. Several types of antifungals are used to treat them and some of them can be radiolabeled with a gamma emitting agent to allow detection by scintigraphy of foci of infection. Voriconazole is a triazole agent, suitable for the synthesis of a complex linked with the precursor [ 99m Tc(H 2 O) 3 (CO) 3 ] + . The aim of his work was to label and determine the physicochemical and biological characteristics of voriconazole with 99m Tc for the early detection of fungal infections. Radiochemical purity was determined by HPLC and the complex remained stable during at least 120 min. In vivo studies in rats bearing either sterile inflammation, infection with C. Albicans or A. Niger showed differentiation of the processes not only in biodistribution but also in scintigraphic images

  8. Gamma--gamma directional correlations and coincidence studies in /sup 154/Gd

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, J B; Gupta, S L; Hamilton, J H; Ramayya, A V [Vanderbilt Univ., Nashville, Tenn. (USA). Dept. of Physics; Delhi Univ. (India). Ramjas Coll.)

    1977-06-01

    The intensities, placements and E2/M1 mixing ratios of transitions in the decay of /sup 154/Eu have been carefully studied to provide accurate data for microscopic calculations. Coincidence relationships in thhe decay of /sup 154/Eu have been studied extensively with a multiparameter ..gamma..-..gamma.. coincidence system with two large volume Ge(Li) detectors. Spectra in coincidence with twenty energy gates were analyzed. Twenty-nine new coincidence relationships were established and confirmed most, but not all, of several levels previously assigned by energy fits only. From an analysis of coincidence spectra and singles spectra with a 18% efficiency Ge(Li) detector new information on the gamma-ray intensities were obtained. Precise values of the E2/M1 mixing ratios of transitions from the gamma- and beta-vibrational bands to the g.s. band have been determined from ..gamma..-..gamma.. directional correlation measurements with a NaI(Tl)-Ge(Li) detector coincidence system. Mixing ratios were obtained for a number of other transitions including those from KPI = 0/sup -/ and 2+ bands from direct and skipped cascade correlations.

  9. Gamma-spectrometric analysis of river sediments collected around phosphate fertilizer industries

    International Nuclear Information System (INIS)

    Gallardo, M.C.; Garcia-Leon, M.; Mundi, M.; Respaldiza, M.A.

    1993-01-01

    Gamma-ray spectrometric analysis has been carried out on sediments collected in an estuarine system formed by two major rivers in southern Spain. The results show clearly that important amounts of natural radioactivity are accumulating on the bed of both rivers. This radioactivity appears to originate from effluent from several phoshate fertilizer factories adjacent to the estuary. (author)

  10. A very accurate method for sentinel lymph node investigation: Gamma detecting probe associated with SPECT examination for depth

    International Nuclear Information System (INIS)

    Ascoli, G.; Cinti, P.; Nonni, M.; Rossi, B.

    2002-01-01

    Aim: aim of this study is to magnify the lymphoscintigraphy examination by gamma probe with SPECT acquisition for very accurate detection of depth of axilla node in patients affected by melanoma. Methods: according to physiological peculiarities the lymphatic system plays a very important role and represents the most important barrier to neoplastic cells spreading. The 'sentinel node' is the first lymph node draining the affected area. The tendency for surgery is a 'preventive' axillary dissection, even in presence of a clinically negative examination. In fact a high percentage of clinically negative lymph node shows a positive histology (presence of metastatic cells). The nuclear medicine method for researching 'sentinel node' is represented by a regional lymphoscintigraphy with normal gamma camera with a large field of view followed by examination with gamma detecting probe and, in following day, controlled in operating room to confirm the presence of the node early identified. We have completed this protocol with SPECT examination of affected axilla by use of injected laboratory capillary around axilla to perform an exact investigation of node depth. Discussion: Our experience in 150 cases in 18 months shows 100% of axilla 'sentinel node' detection, 25 cases with positive histologic examination and subsequently axillary dissection. Conclusions: In conclusion the scintigraphic examination with lymphoscintigraphy represents a good tool for management of patient with melanoma and the use of ''targeting' with collimated SPECT represent a very aid for the surgeon in reduction time for detection and dissection of lymph node, with high reduction of anesthesia duration

  11. Two-photon widths of the chi(c0,2) states and helicity analysis for chi(c2) -> gamma gamma

    NARCIS (Netherlands)

    Ablikim, M.; Achasov, M. N.; Ambrose, D. J.; An, F. F.; An, Q.; An, Z. H.; Bai, J. Z.; Ban, Y.; Becker, J.; Berger, N.; Bertani, M.; Bian, J. M.; Boger, E.; Bondarenko, O.; Boyko, I.; Briere, R. A.; Bytev, V.; Cai, X.; Calcaterra, A.; Cao, G. F.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, J. C.; Chen, M. L.; Chen, S. J.; Chen, Y.; Chen, Y. B.; Cheng, H. P.; Chu, Y. P.; Cronin-Hennessy, D.; Dai, H. L.; Dai, J. P.; Dedovich, D.; Deng, Z. Y.; Denig, A.; Denysenko, I.; Destefanis, M.; Ding, W. M.; Ding, Y.; Dong, L. Y.; Dong, M. Y.; Du, S. X.; Fang, J.; Fang, S. S.; Fava, L.; Feldbauer, F.; Feng, C. Q.; Ferroli, R. B.; Fu, C. D.; Fu, J. L.; Gao, Y.; Geng, C.; Goetzen, K.; Gong, W. X.; Gradl, W.; Greco, M.; Gu, M. H.; Gu, Y. T.; Guan, Y. H.; Guo, A. Q.; Guo, L. B.; Guo, Y. P.; Han, Y. L.; Hao, X. Q.; Harris, F. A.; He, K. L.; He, M.; He, Z. Y.; Held, T.; Heng, Y. K.; Hou, Z. L.; Hu, H. M.; Hu, J. F.; Hu, T.; Huang, B.; Huang, G. M.; Huang, J. S.; Huang, X. T.; Huang, Y. P.; Hussain, T.; Ji, C. S.; Ji, Q.; Ji, X. B.; Ji, X. L.; Jia, L. K.; Jiang, L. L.; Jiang, X. S.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Jing, F. F.; Kalantar-Nayestanaki, N.; Kavatsyuk, M.; Kuehn, W.; Lai, W.; Lange, J. S.; Leung, J. K. C.; Li, C. H.; Li, Cheng; Li, Cui; Li, D. M.; Li, F.; Li, G.; Li, H. B.; Li, J. C.; Li, K.; Li, Lei; Li, N. B.; Li, Q. J.; Li, S. L.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. N.; Li, X. Q.; Li, X. R.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, G. R.; Liao, X. T.; Liu, B. J.; Liu, B. J.; Liu, C. L.; Liu, C. X.; Liu, C. Y.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H.; Liu, H. B.; Liu, H. H.; Liu, H. M.; Liu, H. W.; Liu, J. P.; Liu, K. Y.; Liu, Kai; Liu, Kun; Liu, P. L.; Liu, S. B.; Liu, X.; Liu, X. H.; Liu, Y.; Liu, Y. B.; Liu, Z. A.; Liu, Zhiqiang; Liu, Zhiqing; Loehner, H.; Lu, G. R.; Lu, H. J.; Lu, J. G.; Lu, Q. W.; Lu, X. R.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, T.; Luo, X. L.; Lv, M.; Ma, C. L.; Ma, F. C.; Ma, H. L.; Ma, Q. M.; Ma, S.; Ma, T.; Ma, X. Y.; Ma, Y.; Maas, F. E.; Maggiora, M.; Malik, Q. A.; Mao, H.; Mao, Y. J.; Mao, Z. P.; Messchendorp, J. G.; Min, J.; Min, T. J.; Mitchell, R. E.; Mo, X. H.; Morales, C. Morales; Motzko, C.; Muchnoi, N. Yu.; Nefedov, Y.; Nicholson, C.; Nikolaev, I. B.; Ning, Z.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Park, J. W.; Pelizaeus, M.; Peters, K.; Ping, J. L.; Ping, R. G.; Poling, R.; Prencipe, E.; Pun, C. S. J.; Qi, M.; Qian, S.; Qiao, C. F.; Qin, X. S.; Qin, Y.; Qin, Z. H.; Qiu, J. F.; Rashid, K. H.; Rong, G.; Ruan, X. D.; Sarantsev, A.; Schulze, J.; Shao, M.; Shen, C. P.; Shen, X. Y.; Sheng, H. Y.; Shepherd, M. R.; Song, X. Y.; Spataro, S.; Spruck, B.; Sun, D. H.; Sun, G. X.; Sun, J. F.; Sun, S. S.; Sun, X. D.; Sun, Y. J.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, X.; Thorndike, E. H.; Tian, H. L.; Toth, D.; Ullrich, M.; Varner, G. S.; Wang, B.; Wang, B. Q.; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, Q.; Wang, Q. J.; Wang, S. G.; Wang, X. F.; Wang, X. L.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. Y.; Wei, D. H.; Weidenkaff, P.; Wen, Q. G.; Wen, S. P.; Werner, M.; Wiedner, U.; Wu, L. H.; Wu, N.; Wu, S. X.; Wu, W.; Wu, Z.; Xia, L. G.; Xiao, Z. J.; Xie, Y. G.; Xiu, Q. L.; Xu, G. F.; Xu, G. M.; Xu, H.; Xu, Q. J.; Xu, X. P.; Xu, Y.; Xu, Z. R.; Xue, F.; Xue, Z.; Yan, L.; Yan, W. B.; Yang, H. X.; Yang, T.; Yang, Y.; Yang, Y. X.; Ye, H.; Ye, M.; Ye, M. H.; Yu, B. X.; Yu, C. X.; Yu, J. S.; Yu, S. P.; Yuan, C. Z.; Yuan, W. L.; Yuan, Y.; Zafar, A. A.; Zallo, A.; Zeng, Y.; Zhang, B. X.; Zhang, B. Y.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J.; Zhang, J. G.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, L.; Zhang, S. H.; Zhang, T. R.; Zhang, X. J.; Zhang, X. Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. S.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, H. S.; Zhao, J. W.; Zhao, K. X.; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, S. J.; Zhao, T. C.; Zhao, X. H.; Zhao, Y. B.; Zhao, Z. G.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, Y. H.; Zheng, Z. P.; Zhong, B.; Zhong, J.; Zhou, L.; Zhou, X. K.; Zhou, X. R.; Zhu, C.; Zhu, K.; Zhu, K. J.; Zhu, S. H.; Zhu, X. L.; Zhu, X. W.; Zhu, Y. M.; Zhu, Y. S.; Zhu, Z. A.; Zhuang, J.; Zou, B. S.; Zou, J. H.; Zuo, J. X.

    2012-01-01

    Based on a data sample of 106 X 10(6) psi' events collected with the BESIII detector, the decays psi' -> gamma chi(c0,2), chi(c0,2) -> gamma gamma are studied to determine the two-photon widths of the chi(c0,2) states. The two-photon decay branching fractions are determined to be B(chi(c0) -> gamma

  12. Quality-assurance techniques used with automated analysis of gamma-ray spectra

    International Nuclear Information System (INIS)

    Killian, E.W.; Koeppen, L.D.; Femec, D.A.

    1994-01-01

    In the course of developing gamma-ray spectrum analysis algorithms for use by the Radiation Measurements Laboratory at the Idaho National Engineering Laboratory (INEL), several techniques have been developed that enhance and verify the quality of the analytical results. The use of these quality-assurance techniques is critical when gamma-ray analysis results from low-level environmental samples are used in risk assessment or site restoration and cleanup decisions. This paper describes four of the quality-assurance techniques that are in routine use at the laboratory. They are used for all types of samples, from reactor effluents to environmental samples. The techniques include: (1) the use of precision pulsers (with subsequent removal) to validate the correct operation of the spectrometer electronics for each and every spectrum acquired, (2) the use of naturally occurring and cosmically induced radionuclides in samples to help verify that the data acquisition and analysis were performed properly, (3) the use of an ambient background correction technique that involves superimposing (open-quotes mappingclose quotes) sample photopeak fitting parameters onto multiple background spectra for accurate and more consistent quantification of the background activities, (4) the use of interactive, computer-driven graphics to review the automated locating and fitting of photopeaks and to allow for manual fitting of photopeaks

  13. Processing of gamma-ray spectra employing a Fourier deconvolver for the analysis of complex spectra

    International Nuclear Information System (INIS)

    Madan, V.K.; Rattan, S.S.

    1996-01-01

    Processing of a nuclear spectrum e.g. gamma ray spectrum is concerned with the estimation of energies and intensities of radiation. The processing involves filtering, peak detection and its significance, baseline delineation, the qualitative and the quantitative analysis of singlets and multiplets present in the spectrum. The methodology for the analysis of singlets is well established. However, the analysis of multiplets provides a challenge and is a extremely difficult problem. This report incorporates a Fourier deconvolver for the quantitative analysis of doublets separated by more than a full width at half maximum. The method is easy to implement. The report discusses the methodology, mathematical analysis, and the results obtained by analyzing both synthetic and observed spectra. A computer program, developed for the analysis of a nuclear spectrum, was verified by analyzing a 152 Eu gamma ray spectrum. The proposed technique compared favourably with SAMPO and MDFT method. (author). 16 refs., 3 tabs

  14. Analysis of multiphase flows using dual-energy gamma densitometry and neural networks

    International Nuclear Information System (INIS)

    Bishop, C.M.; James, G.D.

    1993-01-01

    Dual-energy gamma densitometry offers a powerful technique for the non-intrusive analysis of multiphase flows. By employing multiple beam lines, information on the phase configuration can be obtained. Once the configuration is known, it then becomes possible in principle to determine the phase fractions. In practice, however, the extraction of the phase fractions from the densitometer data is complicated by the wide variety of phase configurations which can arise, and by the considerable difficulties of modelling multiphase flows. In this paper we show that neural network techniques provide a powerful approach to the analysis of data from dual-energy gamma densitometers, allowing both the phase configuration and the phase fractions to be determined with high accuracy, whilst avoiding the uncertainties associated with modelling. The technique is well suited to the determination of oil, water and gas fractions in multiphase oil pipelines. Results from linear and non-linear network models are compared, and a new technique for validating the network output is described. (orig.)

  15. Gallium-68 DOTA-TATE Positron Emission Tomography/Computed Tomography: Scintigraphic Changes of Adrenal Glands Following Management of Ectopic Cushing's Syndrome by Steroidogenesis Inhibitors

    International Nuclear Information System (INIS)

    Huang, Yu-Ting; Aziz, Shaikh Irfan; Kumar, Aravind S. Ravi

    2014-01-01

    In the era of emerging functional imaging techniques, an understanding of the effects of hormonal therapies on the scintigraphic appearance of endocrine organs is desirable to minimize the erroneous scan interpretation. The mechanisms by which changes in the scintigraphic appearance of endocrine organs occur however sometimes remain ambiguous. This case demonstrates the gallium-68 (Ga-68) DOTA-TATE positron emission tomography/computed tomography (CT) appearance of adrenal glands following management with steroidogenesis inhibitors. The potential mechanisms underlying this change are discussed. A 17-year-old boy with adrenocorticotropic hormone (ACTH) dependent Cushing's syndrome secondary to ectopic ACTH secretion underwent pre- and post-metyrapone and dexamethasone treatment Ga-68 DOTA-TATE scans 4 months apart. Pretreatment, both adrenals demonstrated normal symmetrical prominent Ga-68 DOTA-TATE uptake and normal CT appearance. The posttherapy scan revealed marked symmetrical suppression of Ga-68 DOTA-TATE uptake, but with bilateral adrenal hypertrophy on CT

  16. Pulse shape analysis for the gamma-ray tracking detector Agata

    International Nuclear Information System (INIS)

    Olariu, A.

    2007-10-01

    Agata is the European project for a 4π gamma-ray tracking array of 180 Ge detectors and is expected to have a detection sensitivity higher by 3 orders of magnitude than that of the present generation of gamma spectrometers. The trajectories of the photons inside a Ge crystal are reconstituted, which allows the determination of the initial energy of the incident photons as the total energy deposited along the track. The sequence of a γ-ray scattering process is too fast compared with the time resolution of the detector to be measured electronically, so tracking algorithms are necessary. Gamma-ray tracking detectors are operating in position sensitive mode it means that Ge crystal are segmented in order to facilitate the localization of the gamma interactions. It is possible to improve the position resolution by using the information conveyed by the shape of the detector signal. The task of the PSA (Pulse Shape Analysis) algorithm is to analyze this signal and extract the number of interactions, the position and the energy of each interaction. PSA algorithms rely on a basis of reference signals given by single interactions and that are obtained through an experimental characterization of the detector with scanning systems. The matrix method is a new PSA algorithm that consists in fitting linearly the detector signal with a set of calculated signals. We have tested this method with both simulated and measured signals. In the case of simulated single interactions the position resolution is 1.4 mm which is within Agata's specifications. For measured signals we have obtained mean positional errors of 3.2 mm at the front end of the detector an 4.8 mm at the back end

  17. 201Tl scintigraphic evaluation of tumor mass and viability of bone and soft-tissue tumors

    International Nuclear Information System (INIS)

    Tsuda, Takatoshi; Kubota, Masahiro; Yoshida, Satoru; Shibata, Masahito; Wakabayashi, Jun-ichi; Obata, Hiroyuki; Matsuyama, Toshikatsu; Usui, Masamichi; Ishii, Sei-ichi.

    1994-01-01

    To characterize 201 Tl uptake in patients with bone and soft-tissue tumor, we studied 49 patients with surgically proven tumors and one patient with a tumor diagnosed arteriographically. In 37 of our 50 patients, the tumor was evaluated with 201 Tl and arteriography. Moreover, in 14 of patients with pre-operative chemotherapy, pathologic changes were graded on the basis of percent tumor necrosis as defined histologically. The percent tumor necrosis histologically was compared with changes in the scintigraphic and conventional angiographic studies. Radiologic comparisons demonstrated a high degree of correlation with images of 201 Tl and both arterial and blood pool phase of 99m Tc-HMDP. Ninety-six percent of 28 malignant tumors had positive 201 Tl uptake. None of the patients showed any thallium accumulation in the soft tissues or skeleton adjacent to the lesion. Activity of 201 Tl was mainly dependent upon a tumor blood flow and a vascular density. In of 14 cases with the preoperative chemotherapeutic treatment, 201 Tl scintigraphic changes showed concordance with % tumor necrosis. Thallium-201 was superior to 99m Tc-HMDP in predicting tumor response to chemotherapy. Interestingly, delayed images of 99m Tc-HMDP of 5 responders with >90% tumor necrosis showed decreased uptake in the adjacent bone to the tumor mass lesions. It seems to be quite all right to consider that a major determinant of 201 Tl uptake is intratumoral angiogenecity, which is closely connected with tumor viability. Therefore, 201 Tl is a sensitive radiopharmaceutical for detection of vascular rich bone and soft-tissue tumors, and appears to be a simple and an accurate test for evaluating the response to specific therapeutic regimens of malignant bone and soft-tissue tumors. (author)

  18. Acetabular stress fractures in military endurance athletes and recruits: incidence and MRI and scintigraphic findings

    International Nuclear Information System (INIS)

    Williams, T.R.; Puckett, M.L.; Shin, A.Y.; Gorman, J.D.; Denison, G.

    2002-01-01

    Objective: To evaluate the incidence and the MRI and scintigraphic appearance of acetabular stress (fatigue) fractures in military endurance athletes and recruits. Design and patients: One hundred and seventy-eight active duty military endurance trainees with a history of activity-related hip pain were evaluated by both MRI and bone scan over a 2-year period. Patients in the study ranged in age from 17 to 45 years. They had hip pain related to activity and had plain radiographs of the hip and pelvis that were interpreted as normal or equivocal. The study was originally designed to evaluate the MRI and scintigraphic appearance of femoral neck stress fractures. Patients had scintigraphy and a limited MRI examination (coronal imaging only) within 48 h of the bone scan. Twelve patients demonstrated imaging findings compatible with acetabular stress fractures. Results: Stress fractures are common in endurance athletes and in military populations; however, stress fracture of the acetabulum is uncommon. Twelve of 178 patients (6.7%) in our study had imaging findings consistent with acetabular stress fractures. Two patterns were identified. Seven of the 12 (58%) patients had acetabular roof stress fractures. In this group, two cases of bilateral acetabular roof stress fractures were identified, one with a synchronous tensile sided femoral neck stress fracture. The remaining five of 12 (42%) patients had anterior column stress fractures, rarely occurring in isolation, and almost always occurring with inferior pubic ramus stress fracture (4 of 5, or 80%). One case of bilateral anterior column stress fractures was identified without additional sites of injury. Conclusions: Stress fractures are commonplace in military populations, especially endurance trainees. Acetabular stress fractures are rare and therefore unrecognized, but do occur and may be a cause for activity-related hip pain in a small percentage of military endurance athletes and recruits. (orig.)

  19. Development of isotope dilution gamma-ray spectrometry for plutonium analysis

    Energy Technology Data Exchange (ETDEWEB)

    Li, T.K.; Parker, J.L. (Los Alamos National Lab., NM (United States)); Kuno, Y.; Sato, S.; Kurosawa, A.; Akiyama, T. (Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan))

    1991-01-01

    We are studying the feasibility of determining the plutonium concentration and isotopic distribution of highly radioactive, spent-fuel dissolver solutions by employing high-resolution gamma-ray spectrometry. The study involves gamma-ray plutonium isotopic analysis for both dissolver and spiked dissolver solution samples, after plutonium is eluted through an ion-exchange column and absorbed in a small resin bead bag. The spike is well characterized, dry plutonium containing {approximately}98% of {sup 239}Pu. By using measured isotopic information, the concentration of elemental plutonium in the dissolver solution can be determined. Both the plutonium concentration and the isotopic composition of the dissolver solution obtained from this study agree well with values obtained by traditional isotope dilution mass spectrometry (IDMS). Because it is rapid, easy to operate and maintain, and costs less, this new technique could be an alternative method to IDMS for input accountability and verification measurements in reprocessing plants. 7 refs., 4 figs., 4 tabs.

  20. Analysis of spectra from portable handheld gamma-ray spectrometry for terrain comparative assessment

    International Nuclear Information System (INIS)

    Dias, Flávio; Lima, Marco; Sanjurjo-Sánchez, Jorge; Alves, Carlos

    2016-01-01

    Geological characteristics can have impacts on societal development by, e.g., geotechnical issues and radiological hazard levels. Due to urban sprawl, there is an increasing need for detailed geological assessment. In this work are analysed data from portable handheld gamma-ray spectra (K, eU and eTh) obtained in granitic and Silurian metaclastic outcrops as well as in an profile, roughly N–S, on soil covered terrains transecting a mapped contact between these rock types (the profile's northern extremity is at locations mapped as granite). Estimations from gamma-ray spectra were studied by univariate and multivariate analyses. K, eU and eTh values were higher on granite in relation to Silurian metaclastic rocks. The northern extremity of the profile showed clearly higher contents of eTh and this contrast was supported by univariate statistical tools (normality plot and Wilk–Shapiro test; boxplots). A ternary plot with the contribution of the elements to gamma-ray absorbed dose showed the separation of granite from Silurian metaclastic rocks with the former being nearer the eTh vertex. The points in the northern extremity of the profile are nearer the eTh vertex than the other points on the profile. These visual suggestions were supported by hierarchical cluster analysis, which was able to differentiate between granite and metaclastic outcrops and separate portions of the profile located on different terrains. Portable gamma-ray spectrometry showed, hence, the potential to distinguish granite and metaclastic terrains at a scale useful for engineering works. These results can also be useful for a first comparative zoning of radiological hazards (which are higher for granite). - Highlights: • Contents of K, eU and eTh were estimated by portable gamma-ray spectra. • Spectra were acquired on a profile across a soil covered granite/metaclastic contact. • Spectra were also collected on granite and Silurian metaclastic outcrops. • Obtained estimations were

  1. Advanced gamma ray balloon experiment ground checkout and data analysis

    Science.gov (United States)

    Blackstone, M.

    1976-01-01

    A software programming package to be used in the ground checkout and handling of data from the advanced gamma ray balloon experiment is described. The Operator's Manual permits someone unfamiliar with the inner workings of the software system (called LEO) to operate on the experimental data as it comes from the Pulse Code Modulation interface, converting it to a form for later analysis, and monitoring the program of an experiment. A Programmer's Manual is included.

  2. Analysis of 137Cs radionuclides activities in Cs-zeolite using gamma spectrometry

    International Nuclear Information System (INIS)

    Noviarty; Ginting, Aslina Br; Anggraini, Dian; Rosika K

    2013-01-01

    137 Cs Radionuclide activity analysis has been carried out. The objective is to determine the activity of the 137 Cs radionuclide in Cs-zeolite are packaged in the form of point source. Analysis of 137 Cs Radionuclide activities in Cs zeolite samples was determined by measuring intensity of the isotope 137 Cs gamma energy at 661.7 keV use-y spectrometer. Before measurement the sample, was first carried out measurements of 137 Cs radionuclide in certified point standards from Amersham, to determine the efficiency value. Result the standard sample measurement obtained the efficiency value of 43.98%. Efficiency values obtained are used in the calculation of sample activity. On the measurement of the intensity of the sample obtained results dose rate 196.4537 cps with a standard deviation of 0.5274. By using standard measurement efficiency values obtained by the calculation of the average activity of the radionuclide 137 Cs in Cs-zeolite 524.9082 Bq. Deviation measurements were below 5% (0.27% ) so that the analysis of the activity of radionuclide 137 Cs in Cs-zeolite samples using gamma spectrometer can be accepted with a 95% confidence level. (author)

  3. Neutron capture prompt gamma-ray activation analysis at the NIST cold neutron research facility

    Energy Technology Data Exchange (ETDEWEB)

    Lindstrom, R M; Zeisler, R; Vincent, D H; Greenberg, R R; Stone, C A; Mackey, E A [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Anderson, D L [Food and Drug Administration, Washington, DC (United States); Clark, D D [Cornell Univ., Ithaca, NY (United States)

    1993-01-01

    An instrument for neutron capture prompt gamma-ray activation analysis (PGAA) has been constructed as part of the Cold Neutron Research Facility at the 20 MW National Institute of Standards and Technology Research Reactor. The neutron fluence rate (thermal equivalent) is 1.5*10[sup 8] n*cm[sup -2]*s[sup -] [sup 1], with negligible fast neutrons and gamma-rays. With compact geometry and hydrogen-free construction, the sensitivity is sevenfold better than an existing thermal instrument. Hydrogen background is thirtyfold lower. (author) 17 refs.; 2 figs.

  4. Stellar Sources of Gamma-ray Bursts

    OpenAIRE

    Luchkov, B. I.

    2011-01-01

    Correlation analysis of Swift gamma-ray burst coordinates and nearby star locations (catalog Gliese) reveals 4 coincidences with good angular accuracy. The random probability is 4\\times 10^{-5}, so evidencing that coincident stars are indeed gamma-ray burst sources. Some additional search of stellar gamma-ray bursts is discussed.

  5. A method to describe inelastic gamma field distribution in neutron gamma density logging.

    Science.gov (United States)

    Zhang, Feng; Zhang, Quanying; Liu, Juntao; Wang, Xinguang; Wu, He; Jia, Wenbao; Ti, Yongzhou; Qiu, Fei; Zhang, Xiaoyang

    2017-11-01

    Pulsed neutron gamma density logging (NGD) is of great significance for radioprotection and density measurement in LWD, however, the current methods have difficulty in quantitative calculation and single factor analysis for the inelastic gamma field distribution. In order to clarify the NGD mechanism, a new method is developed to describe the inelastic gamma field distribution. Based on the fast-neutron scattering and gamma attenuation, the inelastic gamma field distribution is characterized by the inelastic scattering cross section, fast-neutron scattering free path, formation density and other parameters. And the contribution of formation parameters on the field distribution is quantitatively analyzed. The results shows the contribution of density attenuation is opposite to that of inelastic scattering cross section and fast-neutron scattering free path. And as the detector-spacing increases, the density attenuation gradually plays a dominant role in the gamma field distribution, which means large detector-spacing is more favorable for the density measurement. Besides, the relationship of density sensitivity and detector spacing was studied according to this gamma field distribution, therefore, the spacing of near and far gamma ray detector is determined. The research provides theoretical guidance for the tool parameter design and density determination of pulsed neutron gamma density logging technique. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Simultaneous neutron and gamma spectrum adjustment

    International Nuclear Information System (INIS)

    Remec, I.

    1996-01-01

    The spectrum adjustment procedure was extended to simultaneous neutron and gamma spectrum adjustment, and the feasibility of this technique is demonstrated in the analysis of HFIR dosimetry experiments. Conditions in which gamma rays may contribute considerably to radiation damage in steels are discussed. Beryllium helium accumulation fluence monitors (HAFMs) were found to be good monitors in gamma fields of intensities high enough to contribute to steel embrittlement. Use of 237 Np, 238 U, and 9 Be HAFM as gamma dosimeters is proposed for high-dose irradiations in high-energy, high-intensity gamma fields

  7. Improvement and Validation of an Aerosol Deposition Model in the GAMMA-FP, a Fission Product Analysis Module for VHTRs

    International Nuclear Information System (INIS)

    Yoon, Churl; Lim, Hong Sik

    2013-01-01

    GAMMA-FP (GAs Multicomponent Mixture Analysis-Fission Products module), consists of gaseous and aerosol fission product analysis modules. The aerosol FP module adopts a multi-component and multi-sectional aerosol analysis model that has been developed based on the MAEROS model. For the first work of FP module development, the MAEROS model has been implemented and examined against some analytic solutions and experimental data by Yoo et al. An aerosol transport model was developed and implemented in the GAMMA-FP code, and verified. In this study, the aerosol deposition model in the GAMMA-FP code was improved by adopting recent achievements, and was validated against an experimental data available. The aerosol deposition model in the GAMMA-FP code has been improved and successfully validated against the STORM SR-11 deposition test. The simulation with the improved deposition model predicted the matched results with the experimental data well. For future studies, the aerosol deposition model by flow irregularities will be implemented and validated against the TRANSAT bend effect test

  8. Improvement and Validation of an Aerosol Deposition Model in the GAMMA-FP, a Fission Product Analysis Module for VHTRs

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Churl; Lim, Hong Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    GAMMA-FP (GAs Multicomponent Mixture Analysis-Fission Products module), consists of gaseous and aerosol fission product analysis modules. The aerosol FP module adopts a multi-component and multi-sectional aerosol analysis model that has been developed based on the MAEROS model. For the first work of FP module development, the MAEROS model has been implemented and examined against some analytic solutions and experimental data by Yoo et al. An aerosol transport model was developed and implemented in the GAMMA-FP code, and verified. In this study, the aerosol deposition model in the GAMMA-FP code was improved by adopting recent achievements, and was validated against an experimental data available. The aerosol deposition model in the GAMMA-FP code has been improved and successfully validated against the STORM SR-11 deposition test. The simulation with the improved deposition model predicted the matched results with the experimental data well. For future studies, the aerosol deposition model by flow irregularities will be implemented and validated against the TRANSAT bend effect test.

  9. Scintigraphic observation of the course of secondary fracture healing with and without ultrasonic stimulation in animal experiments

    International Nuclear Information System (INIS)

    Klug, W.; Franke, W.G.; Schulze, M.

    1986-01-01

    Secondary fracture healing was studied in the course of closed lower leg fractures in rabbit fracture models by /sup 99m/Tc scintiscanning. The ROI activity quotient increased significantly up to the maximum value, Q = 6.44 on the 14th day after fracture. 61 fractures of the lower leg were treated by ultrasonics from the 14th to the 28th day after fracture. These stimulated fractures showed a biologic healing already on the 168th day. Fractures untreated with ultrasonics could not be proved any more scintigraphically only after the 203rd day after fracture. (author)

  10. Utilizing experimentally derived multi-channel gamma-ray spectra for the analysis of airborne data

    International Nuclear Information System (INIS)

    Grasty, R.L.

    1982-01-01

    Gamma-ray spectra derived from measurements on radioactive concrete calibration pads using plywood sheets to simulate the attenuation effect of air have been successfully tested on airbone data. Cesium-137 at 662 keV, from atomic weapons tests was found to contribute significantly to the airborne spectrum. By fitting the experimental spectra, above the cesium energy, to airborne data, significant increases in accuracy were obtained for the measurement of uranium and thorium, compared to the standard 3-window method. By including a cesium spectrum is the analysis of gamma-ray data from a survey carried out in Saskatchewan, it was found that background radiation due to atmospheric bismuth-214 could be measured more reliably than by using a constant over-water background. Similar results were obtained by monitoring low energy lead-214 gamma-rays at 352 keV

  11. Gamma-ray spectrometry applied to down-hole logging

    International Nuclear Information System (INIS)

    Dumesnil, P.; Umiastowsky, K.

    1983-11-01

    Gamma-ray spectrometry permits to improve the accuracy of natural gamma, gamma-gamma and neutron-gamma geophysical measurements. The probe developed at Centre d'Etudes Nucleaires de Saclay allows down-hole gamma-ray spectrometry. Among others, this probe can be applied to the uranium content determination by selective natural gamma method, down-hole determination of the ash content in the coal by gamma-gamma selective method and elemental analysis by neutron-gamma method. For the calibration and an exact interpretation of the measurements it is important to know the gamma-ray and neutron characteristics of the different kinds of rocks considered as probabilistic variables

  12. Optimization of in situ prompt gamma-ray analysis using a HPGe-252Cf probe

    International Nuclear Information System (INIS)

    Chien Chung; Jiunnhsing Chao

    1991-01-01

    Application of in situ measurements by the neutron-induced prompt gamma-ray activation analysis (PGAA) technique to geochemical analysis and mineral survey have been investigated. An in situ survey of water pollutants by PGAA techniques was first proposed in the authors' previous study, where a 2.7-μg 252 Cf neutron source used in connection with a gamma-ray detecting system to determine water pollutants was described. In this paper the authors describe a modified detection probe designed and constructed to look for the optimum conditions of various-intensity 252 Cf neutron sources in measurement of some elements in lake water. Detecting efficiencies at high-energy regions and detection limits for elements commonly found in polluted lakes were evaluated and predicted to investigate the potential application of the probe for in situ measurements

  13. Comparison of Scintigraphic and Radiological Results in the Diagnosis of Pancreatic Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Deininger, H. K.; Sielaff, H. J. [Strahlenklinik der Staedt. Krankenanstalten Heilbronn, Heilbronn, Federal Republic of Germany (Germany)

    1969-05-15

    The results obtained by pancreas scanning and standard radiological diagnostic methods are compared. The roentgenographic examinations of the stomach, intestine, colon, biliary tract and kidneys were performed by standard X-ray methods and by abdominal tomography with pneumoretroperitoneum. Special methods of a radiological pancreatic diagnosis, e.g. selective angiography and intra-operative pancreatography, are intentionally not considered. So far 192 pancreas scans have been carried out after administration of {sup 75}Se-1 -selenomethionine. The patients were prepared either with a special diet or a fasting period. The quality of the pancreas scans depended on the functional state of the pancreatic tissue and a comparison with phantom studies allowed an approximate estimation of the extent of the parenchymatous lesions. Of the 87 cases with proven pancreatic diseases the results were compared with the scintigraphical and radiological findings. This comparative research illustrates the superiority of pancreas scanning over the conventional rontgenographic methods in the exclusion or detection of pancreatic diseases. (author)

  14. Development of low level 226Ra analysis for live fish using gamma-ray spectrometry

    Science.gov (United States)

    Chandani, Z.; Prestwich, W. V.; Byun, S. H.

    2017-06-01

    A low level 226Ra analysis method for live fish was developed using a 4π NaI(Tl) gamma-ray spectrometer. In order to find out the best algorithm for accomplishing the lowest detection limit, the gamma-ray spectrum from a 226Ra point was collected and nine different methods were attempted for spectral analysis. The lowest detection limit of 0.99 Bq for an hour counting occurred when the spectrum was integrated in the energy region of 50-2520 keV. To extend 226Ra analysis to live fish, a Monte Carlo simulation model with a cylindrical fish in a water container was built using the MCNP code. From simulation results, the spatial distribution of the efficiency and the efficiency correction factor for the live fish model were determined. The MCNP model will be able to be conveniently modified when a different fish or container geometry is employed as fish grow up in real experiments.

  15. Prompt Gamma Ray Analysis of Soil Samples

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A.; Khiari, F.Z.; Haseeb, S.M.A.; Hussein, Tanvir; Khateeb-ur-Rehman [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia); Isab, A.H. [Department of Chemistry, King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2015-07-01

    Neutron moderation effects were measured in bulk soil samples through prompt gamma ray measurements from water and benzene contaminated soil samples using 14 MeV neutron inelastic scattering. The prompt gamma rays were measured using a cylindrical 76 mm x 76 mm (diameter x height) LaBr{sub 3}:Ce detector. Since neutron moderation effects strongly depend upon hydrogen concentration of the sample, for comparison purposes, moderation effects were studied from samples containing different hydrogen concentrations. The soil samples with different hydrogen concentration were prepared by mixing soil with water as well as benzene in different weight proportions. Then, the effects of increasing water and benzene concentrations on the yields of hydrogen, carbon and silicon prompt gamma rays were measured. Moderation effects are more pronounced in soil samples mixed with water as compared to those from soil samples mixed with benzene. This is due to the fact that benzene contaminated soil samples have about 30% less hydrogen concentration by weight than the water contaminated soil samples. Results of the study will be presented. (authors)

  16. Self-attenuation of gamma rays during radioactivity concentration analysis of environmental samples

    International Nuclear Information System (INIS)

    Watson, D.; Dharmasiri, J.; Akber, R.

    2001-01-01

    Gamma spectroscopy using HPGe detector systems is a readily used technique for routine analysis of radioactivity in environmental samples. The systems are generally calibrated using standards of known radioactivity and composition. Radioactivity in environmental samples is generally distributed in the bulk of the material. When a sample of finite thickness is analysed through gamma spectroscopy, a proportion of the gamma rays emitted from the sample is either stopped or scattered from the sample material itself. These processes of self-absorption and self-attenuation depend upon the physical and elemental composition of the sample and the energy of the gamma radiation. Since environmental samples vary in composition, instrument calibration using a fixed matrix composition may not be valid for a diversity of samples. We selected and analysed five sample matrices to investigate the influence of self-absorption and self-attenuation in environmental samples. Our selection consisted of bentonite and kaolin representing clay, quartz representing silica, ash representing prepared biota, and analytical grade MnO 2 representing a co-precipitant used for extractive radioactivity from aqueous samples. Our findings show that within 5% of uncertainty the silica based standards can be used to cover the environmental samples of varying clay (silica content). The detection efficiency for ash and MnO 2 could be different particularly in the 30 - 100 keV energy range. The differences in sample behaviour can be explained on the basis of atomic number, mass number and density

  17. Correlation analysis of measurement result between accelerator mass spectrometry and gamma counter

    International Nuclear Information System (INIS)

    Minamimoto, Ryogo; Cheng, C.; Oka, Takashi; Inoue, Tomio; Hamabe, Yoshimi; Shimoda, Marika

    2010-01-01

    The guidelines for microdosing in clinical trials were published in Japan in 2008 following the guidelines of the European Medicines Agency and the Food and Drug Administration. They recommend utilizing accelerator mass spectrometry (AMS) and positron emission tomography as candidates for monitoring drug metabolites in preclinical studies. We correlate the two methods by measuring appropriately labeled tissue samples from various mouse organs using both AMS and gamma counter. First, we measured the 14 C background levels in mouse organs using the AMS system. We then clarified the relationship between AMS and gamma counter by simultaneously administering 14 C-2-fluoro-2-deoxyglucose ( 14 C-FDG) and 18 F-2-fluoro-2-deoxyglucose ( 18 F-FDG). Tissue distribution was examined after 30 min, 1 h, 2 h and 4 h using the AMS system for 14 C-FDG and gamma counter for 18 F-FDG. Background 14 C levels were subtracted from the data obtained with radiotracer administration. The background 14 C concentration differed with tissue type measured. Background 14 C concentration in mouse liver was higher than in other organs, and was approximately 1.5-fold that in blood. The correlation coefficient (r) of the measurements between AMS ( 14 C-FDG) and gamma counter ( 18 F-FDG) was high in both normal (0.99 in blood, 0.91 in brain, 0.61 in liver and 0.78 in kidney) and tumor-bearing mice (0.95 in blood and 0.99 in tumor). The clearance profile of 18 F-FDG was nearly identical to that of 14 C-FDG measured with AMS. Accelerator mass spectrometry analysis has an excellent correlation with biodistribution measurements using gamma counter. Our results suggest that the combination of AMS and positron emission tomography (PET) can act as a complementary approach to accelerate drug development. (author)

  18. Prompt gamma activation analysis (PGAA) and short-lived neutron activation analysis (NAA) applied to the characterization of legacy materials

    International Nuclear Information System (INIS)

    English, G.A.; Firestone, R.B.; Perry, D.L.; Reijonen, J.P.; Ka-Ngo Leung; Garabedian, G.F.; Molnar, G.L.; Revay, Zs.

    2008-01-01

    Without quality historical records that provide the composition of legacy materials, the elemental and/or chemical characterization of such materials requires a manual analytical strategy that may expose the analyst to unknown toxicological hazards. In addition, much of the existing legacy inventory also incorporates radioactivity, and, although radiological composition may be determined by various nuclear-analytical methods, most importantly, gamma-spectroscopy, current methods of chemical characterization still require direct sample manipulation, thereby presenting special problems with broad implications for both the analyst and the environment. Alternately, prompt gamma activation analysis (PGAA) provides a 'single-shot' in-situ, non-destructive method that provides a complete assay of all major entrained elemental constituents. Additionally, neutron activation analysis (NAA) using short-lived activation products complements PGAA and is especially useful when NAA activation surpasses the PGAA in elemental sensitivity. (author)

  19. Prompt gamma activation analysis (PGAA) and short-lived neutron activation analysis (NAA) applied to the characterization of legacy materials

    International Nuclear Information System (INIS)

    Firestone, Richard B; English, G.A.; Firestone, R.B.; Perry, D.L.; Reijonen, J.P.; Leung, Ka-Ngo; Garabedian, G.F.; Molnar, G.L.; Revay, Zs.

    2008-01-01

    Without quality historical records that provide the composition of legacy materials, the elemental and/or chemical characterization of such materials requires a manual analytical strategy that may expose the analyst to unknown toxicological hazards. In addition, much of the existing legacy inventory also incorporates radioactivity, and, although radiological composition may be determined by various nuclear-analytical methods, most importantly, gamma-spectroscopy, current methods of chemical characterization still require direct sample manipulation, thereby presenting special problems with broad implications for both the analyst and the environment. Alternately, prompt gamma activation analysis (PGAA) provides a 'single-shot' in-situ, non-destructive method that provides a complete assay of all major entrained elemental constituents.1-3. Additionally, neutron activation analysis (NAA) using short-lived activation products complements PGAA and is especially useful when NAA activation surpasses the PGAA in elemental sensitivity

  20. Passive gamma analysis of the boiling-water-reactor assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Vo, D., E-mail: ducvo@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM (United States); Favalli, A. [Los Alamos National Laboratory, Los Alamos, NM (United States); Grogan, B. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Jansson, P. [Uppsala University, Uppsala (Sweden); Liljenfeldt, H. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); Mozin, V. [Lawrence Livermore National Laboratory, Livermore, CA (United States); Schwalbach, P. [European Atomic Energy Community (EURATOM), Luxemburg (Luxembourg); Sjöland, A. [Swedish Nuclear Fuel and Waste Management Company, Stockholm (Sweden); Tobin, S.; Trellue, H. [Los Alamos National Laboratory, Los Alamos, NM (United States); Vaccaro, S. [European Atomic Energy Community (EURATOM), Luxemburg (Luxembourg)

    2016-09-11

    This research focused on the analysis of a set of stationary passive gamma measurements taken on the spent nuclear fuel assemblies from a boiling water reactor (BWR) using pulse height analysis data acquisition. The measurements were performed on 25 different BWR assemblies in 2014 at Sweden's Central Interim Storage Facility for Spent Nuclear Fuel (Clab). This study was performed as part of the Next Generation of Safeguards Initiative–Spent Fuel project to research the application of nondestructive assay (NDA) to spent fuel assemblies. The NGSI–SF team is working to achieve the following technical goals more easily and efficiently than in the past using nondestructive assay (NDA) measurements of spent fuel assemblies: (1) verify the initial enrichment, burnup, and cooling time of facility declaration; (2) detect the diversion or replacement of pins, (3) estimate the plutonium mass, (4) estimate the decay heat, and (5) determine the reactivity of spent fuel assemblies. The final objective of this project is to quantify the capability of several integrated NDA instruments to meet the aforementioned goals using the combined signatures of neutrons, gamma rays, and heat. This report presents a selection of the measured data and summarizes an analysis of the results. Specifically, trends in the count rates measured for spectral lines from the following isotopes were analyzed as a function of the declared burnup and cooling time: {sup 137}Cs, {sup 154}Eu, {sup 134}Cs, and to a lesser extent, {sup 106}Ru and {sup 144}Ce. From these measured count rates, predictive algorithms were developed to enable the estimation of the burnup and cooling time. Furthermore, these algorithms were benchmarked on a set of assemblies not included in the standard assemblies set used by this research team.

  1. External scintigraphy in monitoring the behavior of pharmaceutical formulations in vivo I: technique for acquiring high-resolution images of tablets

    International Nuclear Information System (INIS)

    Theodorakis, M.C.; Simpson, D.R.; Leung, D.M.; Devous, M. Sr.

    1983-01-01

    A new method for monitoring tablet disintegration in vivo was developed. In this method, the tablets were labeled with a short-lived radionuclide, technetium 99m, and monitored by a gamma camera. Several innovations were introduced with this method. First, computer reconstruction algorithms were used to enhance the scintigraphic images of the disintegrating tablet in vivo. Second, the use of a four-pinhole collimator to acquire multiple views of the tablet resulted in high count rates and reduced acquisition times of the scintigraphic images. Third, the magnification of the scintigraphic images achieved by pinhole collimation led to significant improvement in resolution. Fourth, the radioinuclide was incorporated into the granulation so that the whole mass of the tablet was uniformly labeled with high levels of activity. This technique allowed the continuous monitoring of the disintegration process of tablets in vivo in experimental animals. Multiple pinhole collimation and the labeling process permitted the acquisition of quality scintigraphic images of the labeled tablet every 30 sec. The resolution of the method was tested in vitro and in vivo

  2. Application of gamma-gamma logging in predicting anomalous geodynamic phenomena in hard coal mines

    International Nuclear Information System (INIS)

    Blaha, F.; Keclik, L.

    1980-01-01

    The application is discussed of gamma-gamma logging in the prediction of dynamic events like coal and gas bursts, coal sliding in medium dip seams and rock bumps. The overall analysis of the applied rock characterization method and of the measurement results shows that the prediction possibilities of dynamic events are partly limited due to specific effects of the rock massive. In these cases, however, unambiguous results may be obtained by other geophysical methods such as seismoacoustic testing etc. In most cases, however, the gamma-gamma logging results may be used for estimating the degree of dynamic events or checking the efficiency of preventive measures in the locality under investigation. (author)

  3. Body composition to climate change studies - the many facets of neutron induced prompt gamma-ray analysis

    International Nuclear Information System (INIS)

    Mitra, S.

    2008-01-01

    In-vivo body composition analysis of humans and animals and in-situ analysis of soil using fast neutron inelastic scattering and thermal neutron capture induced prompt-gamma rays have been described. By measuring carbon (C), nitrogen (N) and oxygen (O), protein, fat and water are determined. C determination in soil has become important for understanding below ground carbon sequestration process in the light of climate change studies. Various neutron sources ranging from radio isotopic to compact 14 MeV neutron generators employing the associated particle neutron time-of-flight technique or micro-second pulsing were implemented. Gamma spectroscopy using recently developed digital multi-channel analyzers has also been described

  4. Body composition to climate change studies - the many facets of neutron induced prompt gamma-ray analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mitra,S.

    2008-11-17

    In-vivo body composition analysis of humans and animals and in-situ analysis of soil using fast neutron inelastic scattering and thermal neutron capture induced prompt-gamma rays have been described. By measuring carbon (C), nitrogen (N) and oxygen (O), protein, fat and water are determined. C determination in soil has become important for understanding below ground carbon sequestration process in the light of climate change studies. Various neutron sources ranging from radio isotopic to compact 14 MeV neutron generators employing the associated particle neutron time-of-flight technique or micro-second pulsing were implemented. Gamma spectroscopy using recently developed digital multi-channel analyzers has also been described.

  5. Analysis of characteristic performance curves in radiodiagnosis by an observer

    International Nuclear Information System (INIS)

    Kossovoj, A.L.

    1988-01-01

    Methods and ways of construction of performance characteristic curves (PX-curves) in roentgenology, their qualitative and quantitative estimation are described. Estimation of PX curves application for analysis of scintigraphic and sonographic images is presented

  6. In situ analysis of coal from single electrode resistance, self-potential and gamma-ray logs

    International Nuclear Information System (INIS)

    Kayal, J.R.

    1981-01-01

    Single electrode resistance, self-potential and gamma-ray logging have been carried out in North Karanpura, West Bokaro and Jharia coalfields of Gondwana basin in Eastern India. Correlation of these geophysical logs is found to be very useful in locating the coal beds, determining their accurate depths and thickness and approximate quality. Coal seams have been detected as very high resistive formations compared to sandstone/shale which are interbedded in the coal basin. High or low self-potential values are obtained against the coal beds depending on the borehole fluid conditions. Burnt coals (Jhama) are characterised as highly conductive beds. Gamma ray logs have been effectively used alongwith electrical logs for correlation and identification of coal seams. Further analysis of gamma-ray log data determines a linear relationship with ash content of coal. (author)

  7. Method of gamma transmission analysis for controlling the hydraulic transport of raw coal

    International Nuclear Information System (INIS)

    Pepelnik, R.; Boessow, E.; Fanger, H.U.

    1978-01-01

    The capacity of the methods for measuring gamma absorption developed at GKSS to be used for the analysis of conweyer flows of water/coal/refuse mixtures has been studied. As only the absorption properties of the refuse are essentially different from those of water the refuce is detected with higher accuracy than the coal. In this way the sensitivity of the gamma transmission analysis method agrees with the fact that in coal mining the critical mining parameters are influenced by refuse. The results of the investigations indicate that for measuring times of about 10 sec, accounting for realisitic variations of the chemism of the refuse, the volume shares can be determined with an accuracy of about +- 4.7 V/O of coal and about +- . 5 V/O of refuse. The measuring arrangement for the drift velocity is capable to record also the size and the number of the refuse lumps. The methods described therefore are well suited for controlling an optimal conveying operation. (orig.) [de

  8. Operator's guide for VAXGAP, a gamma-ray spectrum analysis package

    International Nuclear Information System (INIS)

    Killian, E.W.; Femec, D.A.

    1992-08-01

    This report describes the gamma-ray analysis program VAXGAP, which has continually evolved at the Idaho National Engineering Laboratory over a period of several years. It is an integrated suite of computer programs for performing analyses of pulse-height spectra from high-resolution gamma-ray spectrometers and assorted support functions. VAXGAP programs operate on Digital Equipment Corporation (DEC) VAX computers running the VMS operating system, and were written in VAX FORTRAN and DEC Digital Command Language (DCL). These programs make use of DEC GKS and ReGIS for graphical output on standard terminals and printers, and DEC windows for graphics on workstations and terminals that support the X Window System protocol. This report addresses the use of VAXGAP for data acquisition and control, energy scale calibration, and real-time analyses of background and sample pulse-height spectra. Also addressed are the creation and use efficiency tables and isotope libraries, manipulation of spectrum files and their contents, and graphical display of on-going acquisitions, saved spectra, and mathematical fits to spectral peaks

  9. PC based analysis of gamma ray spectra generated by semiconductor detectors

    International Nuclear Information System (INIS)

    Abani, M.C.; Madan, V.K.

    1993-01-01

    This report describes a spectrum analysis method and computer program for analysis of gamma spectra obtained by using semiconductor detectors and multichannel analysers. The analysis steps incorporated are smoothing, peak location using signal processing method of convolution, selectable background subtraction viz linear, polynomial and step like, peak fitting both for singlets and doublets using Mukoyama's method for evaluation of full width at half maximum and area evaluation including errors in its evaluation. The program also provides a facility for energy calibration. Typical results of analysis for singlets and doublets are included. This report is based on Wilson's report which has been modified and extended. The program is written in BASIC and its listing is included in the appendices. (author). 20 refs., 2 figs., 2 tabs

  10. $\\gamma$-$\\gamma$ and $\\gamma$-p events at high energies

    CERN Document Server

    Schuler, Gerhard A.; Gerhard A Schuler; Torbjorn Sjostrand

    1994-01-01

    A real photon has a complicated nature, whereby it may remain unresolved or fluctuate into a vector meson or a perturbative q-qbar pair. Based on this picture, we previously presented a model for gamma-p events that is based on the presence of three main event classes: direct, VMD and anomalous. In gamma-gamma events, a natural generalization gives three-by-three combinations of the nature of the two incoming photons, and thus six distinct event classes. The properties of these classes are constrained by the choices already made, in the gamma-p model, of cut-off procedures and other aspects. It is therefore possible to predict the energy-dependence of the cross section for each of the six components separately. The total cross section thus obtained is in good agreement with data, and also gives support to the idea that a simple factorized ansatz with a pomeron and a reggeon term can be a good approximation. Event properties undergo a logical evolution from p-p to gamma-p to gamma-gamma events, with larger cha...

  11. Radioguided Parathyroidectomy with Portable Mini Gamma-Camera for the Treatment of Primary Hyperparathyroidism

    Directory of Open Access Journals (Sweden)

    Claudio Casella

    2015-01-01

    Full Text Available Background. A proper localisation of pathological parathyroid glands is essential for a minimally invasive approach in the surgical treatment of primary hyperparathyroidism (PHP. The recent introduction of portable mini gamma-cameras (pMGCs enabled intraoperative scintigraphic scanning. The aim of our study is to evaluate the efficacy of this new method and compare it with the preoperative localisation surveys. Methods. 20 patients were studied; they were evaluated preoperatively by neck ultrasound and Tc-sestaMIBI-scintigraphy and intraoperatively with the pMGC IP Guardian 2. The results obtained from the three evaluations were compared. Results. The pMGC presented a sensitivity of 95%, a specificity of 98.89%, and a diagnostic accuracy of 98.18%, which were higher than those of preoperative ultrasound (sensitivity 55%; specificity 95%; diagnostic accuracy 87% and scintigraphy with Tc-sestaMIBI (sensitivity 73.68%; specificity 96.05%; diagnostic accuracy 91.58%. Conclusions. The pMGC can be used effectively as an intraoperative method to find the correct location of the pathological parathyroid glands. The pMGC is more reliable than the currently used preoperative and intraoperative localisation techniques.

  12. A portable medium-resolution gamma-ray spectrometer and analysis software

    Energy Technology Data Exchange (ETDEWEB)

    Lavietes, A.D.; McQuaid, J.H.; Ruhter, W.D.; Buckley, W.M.; Clark, D-L. [Lawrence Livermore National Lab., CA (United States); Paulus, T.J. [EG and G ORTEC, Oak Ridge, TN (United States)

    1996-07-01

    There is a strong need for portable radiometric instrumentation that can both accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need the Safeguards Technology Program at LLNL has developed a hand-held, non-cryogenic, low-power gamma-ray and x-ray measurements and analysis instrument that can both search for and then accurately verify the presence of nuclear materials. We will report on the use of cadmium zinc telluride (CZT) detectors, detector electronics, and the new field-portable instrument being developed. We will also describe the isotopic analysis that allows enrichment measurements to be made accurately in the field. These systems provide capability for safeguards inspection and verification applications and could find application in counter-smuggling operations.

  13. A portable medium-resolution gamma-ray spectrometer and analysis software

    International Nuclear Information System (INIS)

    Lavietes, A.D.; McQuaid, J.H.; Ruhter, W.D.; Buckley, W.M.; Clark, D-L.; Paulus, T.J.

    1996-07-01

    There is a strong need for portable radiometric instrumentation that can both accurately confirm the presence of nuclear materials and allow isotopic analysis of radionuclides in the field. To fulfill this need the Safeguards Technology Program at LLNL has developed a hand-held, non-cryogenic, low-power gamma-ray and x-ray measurements and analysis instrument that can both search for and then accurately verify the presence of nuclear materials. We will report on the use of cadmium zinc telluride (CZT) detectors, detector electronics, and the new field-portable instrument being developed. We will also describe the isotopic analysis that allows enrichment measurements to be made accurately in the field. These systems provide capability for safeguards inspection and verification applications and could find application in counter-smuggling operations

  14. Application of prompt gamma ray analysis to biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Oura, Yasuji; Nakahara, Hiromichi [Graduate School of Science, Tokyo Metropolitan University, Tokyo (Japan); Enomoto, Shuichi [Radioisotope Technology Division, Cyclotron Center, Institute of Physical and Chemical Research (RIKEN), Wako, Saitama (Japan)

    2001-05-01

    Prompt {gamma}-ray activation analysis using the internal monostandard method was applied to organs taken from rats. After B, Cd, or Hg was injected into the rats, the content ratios of B/H, Cd/H, and Hg/H were determined in the brain, kidney, liver, bone, and muscle to study their distribution and metabolism. B was distributed in all organs but was metabolized rapidly. Cd slowly accumulated in the liver and kidney throughout the 65 hours study but no Cd was detected in the brain. Hg accumulated mainly in the kidney 3 hrs after the injection. (author)

  15. A computer program for automatic gamma-ray spectra analysis

    International Nuclear Information System (INIS)

    Hiromura, Kazuyuki

    1975-01-01

    A computer program for automatic analysis of gamma-ray spectra obtained with a Ge(Li) detector is presented. The program includes a method by comparing the successive values of experimental data for the automatic peak finding and method of leastsquares for the peak fitting. The peak shape in the fitting routine is a 'modified Gaussian', which consists of two different Gaussians with the same height joined at the centroid. A quadratic form is chosen as a function representing the background. A maximum of four peaks can be treated in the fitting routine by the program. Some improvements in question are described. (auth.)

  16. On stream ash analysis of coal based on its natural gamma-ray activity

    International Nuclear Information System (INIS)

    Mathew, P.J.

    1986-01-01

    A novel method based on the natural gamma-ray activity of coal has been developed for the on-stream determination of ash. The accuracy of the method has been verified by measuring the natural gamma-ray activity and ash content of coal samples from a number of locations in New Zealand and Australia. The rms differences between % ash by ignition and % ash by the gamma-ray method ranged from 0.65% ash for coal samples from a Queensland mine to 1.6% ash for samples from a southern New South Wales mine. The rms errors include those to geovariance, and due to sampling and sample analysis by conventional means. The error in ash measurement by the gamma-ray method can therefore be reduced by substantially eliminating these errors. A prototype ash analyser was also developed and field-tested at the Huntly East mine. In a four-week test, the prototype gauge was used to determine the ash content of run-of-mine (rom) coal below 20% ash to within +- 1.7% ash. Laboratory studies of coal samples collected during the field test of the prototype gave an error of 0.8% ash for coal samples below 20% ash content. A higher error was observed in the field test compared with laboratory data, and the difference is attributed to errors in sampling from the conveyor belt

  17. Gamma-ray burst polarimeter (GAP)

    International Nuclear Information System (INIS)

    Mihara, Tatehiro; Murakami, Toshio; Yonetoku, Daisuke; Gunji, Shuichi; Kubo, Shin

    2013-01-01

    The gamma-ray burst polarimeter (GAP: GAmma-ray burst Polarimeter), which had been almost handcrafted by scientists, has succeeded in working normally in interplanetary space, and in detecting the polarization of the gamma-ray from a mysterious astronomical object 'gamma-ray burst'. It is the first result of the detectors in the world exclusively aiming at detecting gamma-ray polarization. We mainly describe the hardware of our GAP equipment and show the method of preparing equipment to work in the cosmic space with a tight budget. The mechanical structure, the electronic circuits, the software on the equipment, the data analysis on the earth, and the scientific results gained by the observation just over one year, are presented after explaining the principle of gamma-ray polarization detection. Our design to protect equipment against mechanical shock and cosmic radiation may provide useful information for future preparation of compact satellite. (J.P.N.)

  18. Prevention Effect of Poly-Gamma-Glutamic Acid on Tissue Damage Induced by Gamma Irradiation as a Natural Cross-Linker

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jaehun; Sung, Nakyun; Kim, Jeongsoo; Jo, Euri; Choi, Jongil; Park, Jongheum; Lee, Juwoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, Kwangwon [Eulji Univ. Hospital, Daejeon (Korea, Republic of); Kwon, Jungkee [Chonbuk National Univ., Jeonju (Korea, Republic of); Kim, Taewoon [Jeonbuk Technopark, Jeonju (Korea, Republic of)

    2012-03-15

    This study was to determine the prevention effect of poly-gamma-glutamic acid (PGA) on tissue damage induced by gamma irradiation for development of xenograft. PGA (MW 2000 kDa) extracted from permeated soy bean (natto) was used in this study as natural compound, and glutaraldehyde (GA) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) were used as a control, chemical based cross-linking agents. GA, EDC and PGA treated porcine tendons were gamma-irradiated at the dose of 30 kGy. Prevention effects against tissue damage were measured as the result of tensile strength, hydroxyproline contents and tissue morphological analysis. Tensile of porcine tendon was remarkably decreased by gamma irradiation, but increased in PGA treated group. Morphological analysis showed that collagen structure was broken by gamma irradiation, but attenuated by PGA treatment. Base on the results, it demonstrated that gamma irradiation can induce severe alteration of porcine tendon, but PGA can effectively improve the tissue damage.

  19. Prevention Effect of Poly-Gamma-Glutamic Acid on Tissue Damage Induced by Gamma Irradiation as a Natural Cross-Linker

    International Nuclear Information System (INIS)

    Kim, Jaehun; Sung, Nakyun; Kim, Jeongsoo; Jo, Euri; Choi, Jongil; Park, Jongheum; Lee, Juwoon; Lee, Kwangwon; Kwon, Jungkee; Kim, Taewoon

    2012-01-01

    This study was to determine the prevention effect of poly-gamma-glutamic acid (PGA) on tissue damage induced by gamma irradiation for development of xenograft. PGA (MW 2000 kDa) extracted from permeated soy bean (natto) was used in this study as natural compound, and glutaraldehyde (GA) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) were used as a control, chemical based cross-linking agents. GA, EDC and PGA treated porcine tendons were gamma-irradiated at the dose of 30 kGy. Prevention effects against tissue damage were measured as the result of tensile strength, hydroxyproline contents and tissue morphological analysis. Tensile of porcine tendon was remarkably decreased by gamma irradiation, but increased in PGA treated group. Morphological analysis showed that collagen structure was broken by gamma irradiation, but attenuated by PGA treatment. Base on the results, it demonstrated that gamma irradiation can induce severe alteration of porcine tendon, but PGA can effectively improve the tissue damage

  20. Scintigraphic myocardial imaging with sup(99m)Tc-labelled pyrophosphate of experimentally produced cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Mazurova, Y.; Bradna, P.

    1981-12-01

    Scintigraphic examination of the myocardium using sup(99m)Tc-labelled pyrophosphate was carried out in 10 dogs with experimentally produced cardiomyopathy. This was brought by introvenous administration of high doses of adrenalin and theophylline. The scan was positive in 8 out of 10 dogs. Hot foci were very extensive. The degree of accumulation was however low (2+). Histological examination of the myocardium using the light microscope showed only scarcely distinguishable damage to the tissue without the presence of necrosis. ECG examinations were normal in all cases. By means of sup(99m)Tc-labelled pyrophosphate even very small myocardial disorders can thus be detected. This fact may be of clinical importance for an early diagnosis of heart lesions.

  1. Automated analysis of off-line measured gamma-spectra using UniSampo gamma-ray spectrum analysis software including criterias for alarming systems

    International Nuclear Information System (INIS)

    Nikkinen, M.T.

    2005-01-01

    In many laboratories the number of measured routine gamma-spectra can be significant and the labour work to review all the data is time consuming and expensive task. In many cases the routine sample does not normally contain radiation above a detectable level, and still the review of the spectra has to be performed. By introducing simple rules for emerging conditions, the review work can be significantly reduced. In one case the need to review the environmental measurement spectra was reduced to less than 1% compared to the original need, which in turn made the review personnel available for more useful functions. Using the UniSampo analysis system, the analysis results of spectra that are causing alarming conditions can be transmitted via e-mail to any address. Some systems are even equipped with the capability to forward these results to hand-portable telephones or pagers. This is a very practical solution for automated environmental monitoring, when the sample spectra are collected automatically and transmitted to central computer for further analysis. Set up of an automatic analysis system, rules for the emerging conditions, technical solutions for an automated alarming system and a generic hypothesis test for the alarming system developed for UniSampo analysis software are described. (author)

  2. Influence of the temperature in the measurement of the gamma automatic probe Gamma Tracer; Influencia de la temperatura en la medicion de la sonda gamma automatica Gamma Tracer

    Energy Technology Data Exchange (ETDEWEB)

    Caveda R, C.A.; Dominguez L, O.; Alonso A, D. [CPHR, Calle 20 No. 4113 e/41 y 47, Playa, C.P. 11300, A.P. 6195, C.P. 10600 La Habana (Cuba); Montalvan E, A.; Fabelo B, O. [CIAC, Ave. Finlay Km 2 1/2, Rpto. Puerto Principe, Camaguey 70800 (Cuba)]. e-mail: caveda@cphr.edu.cu

    2006-07-01

    In the following work an analysis of the existent relationship among the measurement of the absorbed dose rate in air due to the environmental gamma radiation and the temperature, magnitudes measured to intervals of 10 minutes by the gamma probe Gamma Tracer located in the post of occident of the National Net of Environmental Radiological Surveillance (RNVRA), in the Center of Protection and Hygiene of the Radiations (CPHR) is made. For it its were analyzed near 100,000 measurements corresponding to the period 2004-2005. For a better processing and interpretation of the data, these were analyzed with one frequency time zone and monthly using the Gamma Red software to which was necessary to add it some options. Finally it was submitted the probe to a heating process inside a stove. The results of the carried out experiments confirmed that the absorbed dose rate in air due to the environmental gamma radiation depends potentially of the probe temperature in the range of environmental temperature to which is subjected daily the same one. (Author)

  3. Advanced concepts for gamma-ray isotopic analysis and instrumentation

    International Nuclear Information System (INIS)

    Buckley, W.M.; Carlson, J.B.

    1994-07-01

    The Safeguards Technology Program at the Lawrence Livermore National Laboratory is developing actinide isotopic analysis technologies in response to needs that address issues of flexibility of analysis, robustness of analysis, ease-of-use, automation and portability. Recent developments such as the Intelligent Actinide Analysis System (IAAS), begin to address these issues. We are continuing to develop enhancements on this and other instruments that improve ease-of-use, automation and portability. Requests to analyze samples with unusual isotopics, contamination, or containers have made us aware of the need for more flexible and robust analysis. We have modified the MGA program to extend its plutonium isotopic analysis capability to samples with greater 241 Am content or U isotopics. We are looking at methods for dealing with tantalum or lead contamination and contamination with high-energy gamma emitters, such as 233 U. We are looking at ways to allow the program to use additional information about the sample to further extend the domain of analyzable samples. These unusual analyses will come from the domain of samples that need to be measured because of complex reconfiguration or environmental cleanup

  4. Precise measurement of {gamma}(K{yields}e {nu}({gamma}))/{gamma}(K{yields}{mu} {nu}({gamma})) and study of K{yields}e {nu} {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, F.; Massarotti, P.; Meola, S.; Napolitano, M. [Dipartimento di Scienze Fisiche dell' Universita ' ' Federico II' ' , Napoli (Italy); INFN Sezione di Napoli, Napoli (Italy); Antonelli, A.; Antonelli, M.; Bencivenni, G.; Bloise, C.; Bossi, F.; Capon, G.; Capussela, T.; Ciambrone, P.; De Lucia, E.; De Simone, P.; Dreucci, M.; Felici, G.; Gatti, C.; Giovannella, S.; Jacewicz, M.; Lanfranchi, G.; Miscetti, S.; Moulson, M.; Murtas, F.; Palutan, M.; Santangelo, P.; Sciascia, B.; Sibidanov, A.; Spadaro, T.; Venanzoni, G. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Archilli, F. [Dipartimento di Fisica dell' Universita ' ' Tor Vergata' ' , Rome (Italy); INFN Sezione di Roma Tor Vergata, Rome (Italy); Beltrame, P.; Denig, A.; Mueller, S. [Johannes Gutenberg-Universitaet, Institut fuer Kernphysik, Mainz (Germany); Bini, C.; De Santis, A.; De Zorzi, G.; Di Domenico, A.; Fiore, S.; Franzini, P.; Gauzzi, P. [Dipartimento di Fisica dell' Universita ' ' La Sapienza' ' , Rome (Italy); INFN Sezione di Roma, Rome (Italy); Bocchetta, S.; Ceradini, F.; Di Micco, B.; Nguyen, F. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); INFN Sezione di Roma Tre, Rome (Italy); Branchini, P.; Graziani, E.; Passeri, A.; Tortora, L. [INFN Sezione di Roma Tre, Rome (Italy); Capriotti, D. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); Di Donato, C. [INFN Sezione di Napoli, Napoli (Italy); Kulikov, V. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Lee-Franzini, J. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); State University of New York, Physics Department, Stony Brook (United States); Martini, M.; Patera, V.; Versaci, R. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Energetica dell' Universita ' ' La Sapienza' ' , Rome (Italy); Valente, P. [INFN Sezione di Roma, Rome (Italy)

    2009-12-15

    We present a precise measurement of the ratio R{sub K}={gamma}(K{yields}e{nu}({gamma}))/{gamma}(K{yields}{mu}{nu}({gamma})) and a study of the radiative process K{yields}e{nu}{gamma}, performed with the KLOE detector. The results are based on data collected at the Frascati e{sup +}e{sup -} collider DA {phi}NE for an integrated luminosity of 2.2 fb{sup -1}. We find R{sub K}=(2.493{+-}0.025{sub stat}{+-}0.019{sub syst}) x 10{sup -5}, in agreement with the Standard Model expectation. This result is used to improve constraints on parameters of the Minimal Supersymmetric Standard Model with lepton flavor violation. We also measured the differential decay rate d {gamma}(K{yields}e{nu}{gamma})/dE{sub {gamma}} for photon energies 10gamma}}<250 MeV. Results are compared with predictions from theory. (orig.)

  5. A new measurement of the rare decay eta -> pi^0 gamma gamma with the Crystal Ball/TAPS detectors at the Mainz Microtron

    Energy Technology Data Exchange (ETDEWEB)

    Nefkens, B M; Prakhov, S; Aguar-Bartolom��, P; Annand, J R; Arends, H J; Bantawa, K; Beck, R; Bekrenev, V; Bergh��user, H; Braghieri, A; Briscoe, W J; Brudvik, J; Cherepnya, S; Codling, R F; Collicott, C; Costanza, S; Danilkin, I V; Denig, A; Demissie, B; Dieterle, M; Downie, E J; Drexler, P; Fil' kov, L V; Fix, A; Garni, S; Glazier, D I; Gregor, R; Hamilton, D; Heid, E; Hornidge, D; Howdle, D; Jahn, O; Jude, T C; Kashevarov, V L; K��ser, A; Keshelashvili, I; Kondratiev, R; Korolija, M; Kotulla, M; Koulbardis, A; Kruglov, S; Krusche, B; Lisin, V; Livingston, K; MacGregor, I J; Maghrbi, Y; Mancel, J; Manley, D M; McNicoll, E F; Mekterovic, D; Metag, V; Mushkarenkov, A; Nikolaev, A; Novotny, R; Oberle, M; Ortega, H; Ostrick, M; Ott, P; Otte, P B; Oussena, B; Pedroni, P; Polonski, A; Robinson, J; Rosner, G; Rostomyan, T; Schumann, S; Sikora, M H; Starostin, A; Strakovsky, I I; Strub, T; Suarez, I M; Supek, I; Tarbert, C M; Thiel, M; Thomas, A; Unverzagt, M; Watts, D P; Werthmueller, D; Witthauer, L

    2014-08-01

    A new measurement of the rare, doubly radiative decay eta->pi^0 gamma gamma was conducted with the Crystal Ball and TAPS multiphoton spectrometers together with the photon tagging facility at the Mainz Microtron MAMI. New data on the dependence of the partial decay width, Gamma(eta->pi^0 gamma gamma), on the two-photon invariant mass squared, m^2(gamma gamma), as well as a new, more precise value for the decay width, Gamma(eta->pi^0 gamma gamma) = (0.33+/-0.03_tot) eV, are based on analysis of 1.2 x 10^3 eta->pi^0 gamma gamma decays from a total of 6 x 10^7 eta mesons produced in the gamma p -> eta p reaction. The present results for dGamma(eta->pi^0 gamma gamma)/dm^2(gamma gamma) are in good agreement with previous measurements and recent theoretical calculations for this dependence.

  6. Event-sequence time series analysis in ground-based gamma-ray astronomy

    International Nuclear Information System (INIS)

    Barres de Almeida, U.; Chadwick, P.; Daniel, M.; Nolan, S.; McComb, L.

    2008-01-01

    The recent, extreme episodes of variability detected from Blazars by the leading atmospheric Cerenkov experiments motivate the development and application of specialized statistical techniques that enable the study of this rich data set to its furthest extent. The identification of the shortest variability timescales supported by the data and the actual variability structure observed in the light curves of these sources are some of the fundamental aspects being studied, that answers can bring new developments on the understanding of the physics of these objects and on the mechanisms of production of VHE gamma-rays in the Universe. Some of our efforts in studying the time variability of VHE sources involve the application of dynamic programming algorithms to the problem of detecting change-points in a Poisson sequence. In this particular paper we concentrate on the more primary issue of the applicability of counting statistics to the analysis of time-series on VHE gamma-ray astronomy.

  7. Development of an automatic prompt gamma-ray activation analysis system

    International Nuclear Information System (INIS)

    Osawa, Takahito

    2013-01-01

    An automatic prompt gamma-ray activation analysis system was developed and installed at the Japan Research Reactor No. 3 Modified (JRR-3M). The main control software, referred to as AutoPGA, was developed using LabVIEW 2011 and the hand-made program can control all functions of the analytical system. The core of the new system is an automatic sample exchanger and measurement system with several additional automatic control functions integrated into the system. Up to fourteen samples can be automatically measured by the system. (author)

  8. X-ray fluorescence and gamma-ray spectrometry combined with multivariate analysis for topographic studies in agricultural soil

    International Nuclear Information System (INIS)

    Castilhos, Natara D.B. de; Melquiades, Fábio L.; Thomaz, Edivaldo L.; Bastos, Rodrigo Oliveira

    2015-01-01

    Physical and chemical properties of soils play a major role in the evaluation of different geochemical signature, soil quality, discrimination of land use type, soil provenance and soil degradation. The objectives of the present study are the soil elemental characterization and soil differentiation in topographic sequence and depth, using Energy Dispersive X-Ray Fluorescence (EDXRF) as well as gamma-ray spectrometry data combined with Principal Component Analysis (PCA). The study area is an agricultural region of Boa Vista catchment which is located at Guamiranga municipality, Brazil. PCA analysis was performed with four different data sets: spectral data from EDXRF, spectral data from gamma-ray spectrometry, concentration values from EDXRF measurements and concentration values from gamma-ray spectrometry. All PCAs showed similar results, confirmed by hierarchical cluster analysis, allowing the data grouping into top, bottom and riparian zone samples, i.e. the samples were separated due to its landscape position. The two hillslopes present the same behavior independent of the land use history. There are distinctive and characteristic patterns in the analyzed soil. The methodologies presented are promising and could be used to infer significant information about the region to be studied. - Highlights: • Characterization of topographic sequence of two hillslopes from agricultural soil. • Employment of EDXRF and gamma-ray spectrometry data combined with PCA. • The combination of green analytical methodologies with chemometric studies allowed soil differentiation. • The innovative methodology is promising for direct characterization of agricultural catchments

  9. Optimisation of beryllium-7 gamma analysis following BCR sequential extraction

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, A. [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Blake, W.H., E-mail: wblake@plymouth.ac.uk [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Keith-Roach, M.J. [Plymouth University, School of Geography, Earth and Environmental Sciences, 8 Kirkby Place, Plymouth PL4 8AA (United Kingdom); Kemakta Konsult, Stockholm (Sweden)

    2012-03-30

    Graphical abstract: Showing decrease in analytical uncertainty using the optimal (combined preconcentrated sample extract) method. nv (no value) where extract activities were gamma counting uncertainties. Extending analysis time significantly is not always an option for batches of samples, owing to the on-going decay of {sup 7}Be (t{sub 1/2} = 53.3 days). Here, three different methods of preparing and quantifying {sup 7}Be extracted using the optimised BCR three-step scheme have been evaluated and compared with a focus on reducing analytical uncertainties. The optimal method involved carrying out the BCR extraction in triplicate, sub-sampling each set of triplicates for stable Be analysis before combining each set and coprecipitating the {sup 7}Be with metal oxyhydroxides to produce a thin source for gamma analysis. This method was applied to BCR extractions of natural {sup 7}Be in four agricultural soils. The approach gave good counting statistics from a 24 h analysis period ({approx}10% (2

  10. Methodology for using prompt gamma activation analysis to measure the binary diffusion coefficient of a gas in a porous medium

    International Nuclear Information System (INIS)

    Rios Perez, Carlos A.; Biegalski, Steve R.; Deinert, Mark R.

    2012-01-01

    Highlights: ► Prompt gamma activation analysis is used to study gas diffusion in a porous system. ► Diffusion coefficients are determined using prompt gamma activation analysis. ► Predictions concentrations fit experimental measurements with an R 2 of 0.98. - Abstract: Diffusion plays a critical role in determining the rate at which gases migrate through porous systems. Accurate estimates of diffusion coefficients are essential if gas transport is to be accurately modeled and better techniques are needed that can be used to measure these coefficients non-invasively. Here we present a novel method for using prompt gamma activation analysis to determine the binary diffusion coefficients of a gas in a porous system. Argon diffusion experiments were conducted in a 1 m long, 10 cm diameter, horizontal column packed with a SiO 2 sand. The temporal variation of argon concentration within the system was measured using prompt gamma activation analysis. The binary diffusion coefficient was obtained by comparing the experimental data with the predictions from a numerical model in which the diffusion coefficient was varied until the sum of square errors between experiment and model data was minimized. Predictions of argon concentration using the optimal diffusivity fit experimental measurements with an R 2 of 0.983.

  11. Radiogenic hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Rey, G; Woellgens, P; Haase, W [Katharinenhospital, Stuttgart (F.R. Germany). Strahlenklinik

    1976-08-01

    The article is about a patient who developed hepatitis after post-operative radiotherapy of a hypernephroma on the right side with /sup 60/Co ..gamma.. radiation. The scintigraph showed a normal-sized liver with parenchymal defects. Therapy consisted of anti-emetics and vitamin preparations.

  12. Positron tomography. Methodology and applications

    International Nuclear Information System (INIS)

    Kellershohn, C.; Comar, D.

    1979-01-01

    Whereas single photon tomography provides a new and rewarding dimension to conventional nuclear medicine, positron tomography makes a new original approach possible of the analysis in vivo of fundamental biological and physiological processes. The main object of both is the sectional representation of the distribution of a radioactive indicator injected into the body system; compared with conventional detectors (gamma cameras and scintigraphic systems) they provide much greater accuracy in localization. The characteristics of these two methods can be presented schematically by comparing their respective advantages and drawbacks [fr

  13. Constraining CKM $\\gamma$ angle at LHCb

    CERN Document Server

    Vallier, Alexis Roger Louis

    2015-01-01

    The current combination of all available tree-level measurements of the CKM angle gamma at LHCb is reported. It includes results obtained from time independent analyses of B+ -> DK+ and of B0 -> DK∗0 decays; and from a time-dependent analysis of Bs0 -> DsK decays. The results represent the world's best single-experiment determination of gamma. The first observation of the Bs->Ds*K decay and the first observation and amplitude analysis of B- -> D+K-pi- are also reported. In addition to these tree measurements, the estimation of gamma from charmless B meson decay, sensitive to loops contribution, is presented.

  14. Radiative decay of the eta-, eta'-mesons in the nonlocal quark model. [eta(eta'). --> gamma gamma. ; eta. -->. pi. /sup +/. pi. /sup -/. gamma. ; eta. -->. pi. /sup 0/2. gamma. ; eta'. -->. rho/sup 0/. gamma. ; eta'. -->. omega gamma. ;. pi. /sup 0/. -->. gamma. e/sup +/e/sup -/; eta(eta'). -->. gamma mu. /sup +/. mu. /sup -/

    Energy Technology Data Exchange (ETDEWEB)

    Efimov, G V; Ivanov, M A; Nogovitsyn, E A [Joint Inst. for Nuclear Research, Dubna (USSR)

    1981-07-01

    P..--> gamma gamma.. (P=..pi../sup 0/, eta, eta'), eta..--> pi../sup +/..pi../sup -/..gamma.., eta..--> pi../sup 0/..gamma gamma.., eta/sup 1/..-->..V..gamma.. (V=rho/sup 0/, ..omega..), p..--> gamma..l/sup +/l/sup -/ (p=..pi../sup 0/, eta, eta') radiation decays are studied for testing the applicability of the non-local quark model for description of the experimental data. The Feynman diagrams of these decays are presented, values of the widths of the Veta..--> gamma gamma.., eta..--> pi../sup +/..pi../sup -/..gamma.., eta..--> pi../sup 0/..gamma gamma.., eta'..--> gamma gamma.., eta'..-->..rho/sup 0/..gamma.., eta'..--> omega gamma.. decays are calculated and given in the form of a table. Calculations are carried out for two values of the eta eta'-crossing angle: THETA=-11 deg and -18 deg. Values of invariant amplitudes of these decays are determined for ..pi../sup 0/..--> gamma..e/sup +/e/sup -/, eta..--> gamma mu../sup +/..mu../sup -/, eta'..--> gamma mu../sup +/..mu../sup -/ decays at THETA=-11 deg and -18 deg. The best agreement with the experimental data is noted to take place at THETA=-11 deg, the determined width of the eta..--> pi../sup 0/..gamma gamma.. decays is underestimated as compared with the experimental one.

  15. A calibration to predict the concentrations of impurities in plutonium oxide by prompt gamma analysis: Revision 1

    International Nuclear Information System (INIS)

    Narlesky, Joshua E.; Foster, Lynn A.; Kelly, Elizabeth J.; Murray, Roy E. IV

    2009-01-01

    Over 5,500 containers of excess plutonium-bearing materials have been packaged for long-term storage following the requirements of DOE-STD- 3013. Knowledge of the chemical impurities in the packaged materials is important because certain impurities, such as chloride salts, affect the behavior of the material in storage leading to gas generation and corrosion when sufficient moisture also is present. In most cases, the packaged materials are not well characterized, and information about the chemical impurities is limited to knowledge of the material's processing history. The alpha-particle activity from the plutonium and americium isotopes provides a method of nondestructive self-interrogation to identify certain light elements through the characteristic, prompt gamma rays that are emitted from alpha-particle-induced reactions with these elements. Gamma-ray spectra are obtained for each 3013 container using a highresolution, coaxial high-purity germanium detector. These gamma-ray spectra are scanned from 800 to 5,000 keV for characteristic, prompt gamma rays from the detectable elements, which include lithium, beryllium, boron, nitrogen, oxygen, fluorine, sodium, magnesium, aluminum, silicon, phosphorus, chlorine, and potassium. The lower limits of detection for these elements in a plutonium-oxide matrix increase with atomic number and range from 100 or 200 ppm for the lightest elements such as lithium and beryllium, to 19,000 ppm for potassium. The peak areas from the characteristic, prompt gamma rays can be used to estimate the concentration of the light-element impurities detected in the material on a semiquantitative basis. The use of prompt gamma analysis to assess impurity concentrations avoids the expense and the risks generally associated with performing chemical analysis on radioactive materials. The analyzed containers are grouped by impurity content, which helps to identify high-risk containers for surveillance and in sorting materials before packaging.

  16. SAMPO 90 - High resolution interactive gamma spectrum analysis including automation with macros

    International Nuclear Information System (INIS)

    Aarnio, P.A.; Nikkinen, M.T.; Routti, J.T.

    1991-01-01

    SAMPO 90 is a high performance gamma spectrum analysis program for personal computers. It uses high resolution color graphics to display calibrations, spectra, fitting results as multiplet components, and analysis results. All the analysis phases can be done either under full interactive user control or by using macros for automated measurement and analysis sequences including the control of MCAs and sample changers. Semi-automated calibrations for peak shapes (Gaussian with exponential tails), detector efficiency, and energy are available with a possibility for user intervention through interactive graphics. Accurate peak area determination of even the most complex multiplets, of up to 32 components, is accomplished using linear, non-linear and mixed mode fitting, where the component energies and areas can be either frozen or allowed to float in arbitrary combinations. Nuclide identification is done using associated lines techniques which allow interference correction for fully overlapping peaks. Peaked Background Subtraction can be performed and Minimum Detectable Activities calculated. Attenuation corrections can be taken into account in detector efficiency calculation. The most common PC-based MCA spectrum formats (Canberra S100, Ortec ACE, Nucleus PCA, ND AccuSpec) are supported as well as ASCII spectrum files. A gamma-line library is included together with an editor for user configurable libraries. The analysis reports and program parameters are fully customizable. Function key macros can be used to automate the most common analysis procedures. Small batch type modules are additionally available for routine work. SAMPO 90 is a result of over twenty man years of programming and contains 25,000 lines of Fortran, 10,000 lines of C, and 12,000 lines of assembler

  17. Digital filtering of scintigrams and an investigation into the application of the fresnel zone plate in nuclear medicine

    International Nuclear Information System (INIS)

    Berg, C.J.M. van den

    1976-01-01

    By lack of media large enough to obtain a gamma-lens gamma radiation imaging detectors are based on collimation by absorbence. At present, routine static studies in Nuclear Medicine generally make use of gamma cameras equiped with conventional collimators of limited resolution characterized by their impulse response function. Two methods of improvement of scintigraphic imaging are investigated in this thesis: i) Digital filtering of scintigrams obtained with a conventional collimator (Chapter III); ii) Use of alternative collimation techniques i.e. the use of coded apertures, especially of Zone Plates

  18. Prompt gamma cold neutron activation analysis applied to biological materials

    International Nuclear Information System (INIS)

    Rossbach, M.; Hiep, N.T.

    1992-01-01

    Cold neutrons at the external neutron guide laboratory (ELLA) of the KFA Juelich are used to demonstrate their profitable application for multielement characterization of biological materials. The set-up and experimental conditions of the Prompt Gamma Cold Neutron Activation Analysis (PGCNAA) device is described in detail. Results for C, H, N, S, K, B, and Cd using synthetic standards and the 'ratio' technique for calculation are reported for several reference materials and prove the method to be reliable and complementary with respect to the elements being determined by INAA. (orig.)

  19. Detection and localization of lower gastrointestinal bleeding site with scintigraphic techniques

    International Nuclear Information System (INIS)

    Alavi, A.

    1988-01-01

    Successful management of acute gastrointestinal (GI) bleeding frequently depends on accurate localization of the bleeding site. History and clinical findings are often misleading in localizing the site of hemorrhage. The widespread application of flexible endoscopy and selective arteriography now provides accurate diagnoses for the majority of patients with upper GI tract hemorrhage, but lower GI bleeding still is a serious diagnostic problem. Endoscopy and barium studies are of limited value in examining the small bowel and colon in the face of active hemorrhage. Arteriography, although successful in many cases, has limitations. The angiographic demonstration of bleeding is possible only when the injection of contrast material coincides with active bleeding. Since lower GI bleeding is commonly intermittent rather than continuous, a high rate of negative angiographic examinations has been reported. Repeated angiography to pursue recurrent episodes of bleeding is impractical. Because of these shortcomings, in the past decade several noninvasive scintigraphic techniques have been developed to detect and localize sites of GI bleeding. In this chapter the authors discuss details related to the technetium 99m sulfur colloid (Tc-SC) and technetium 99m-labeled red blood cell (Tc-RBC) techniques

  20. Gamma spectroscopy analysis of archived Marshall Island soil samples

    International Nuclear Information System (INIS)

    Herman, S.; Hoffman, K.; Lavelle, K.; Trauth, A.; Glover, S.E.; Connick, W.; Spitz, H.; LaMont, S.P.; Hamilton, T.

    2016-01-01

    Four samples of archival Marshall Islands soil were subjected to non-destructive, broad energy (17 keV-2.61 MeV) gamma-ray spectrometry analysis using a series of different high-resolution germanium detectors. These archival samples were collected in 1967 from different locations on Bikini Atoll and were contaminated with a range of fission and activation products, and other nuclear material from multiple weapons tests. Unlike samples collected recently, these samples have been stored in sealed containers and have been unaffected by approximately 50 years of weathering. Initial results show that the samples contained measurable but proportionally different concentrations of plutonium, 241 Am, and 137 Cs, and 60 Co. (author)

  1. The significance of 123I-BMIPP delayed scintigraphic imaging in cardiac patients.

    Science.gov (United States)

    Akashi, Yoshihiro J; Kida, Keisuke; Suzuki, Kae; Inoue, Koji; Kawasaki, Kensuke; Yamauchi, Masahiro; Musha, Haruki; Anker, Stefan D

    2007-04-25

    Earlier studies have not fully investigated the significance of radionuclide planar imaging in cardiac patients using the fatty acid analogue 123I-beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP). This study was to clarify the effectiveness of 123I-BMIPP in assessing the heart-to-mediastinum ratio (H/M) and myocardial washout rate (WR) in patients with heart disease. Myocardial 123I-BMIPP imaging was performed in 33 patients (20 with chronic heart failure [CHF] and 13 with stable angina pectoris [AP]) and 11 control subjects. Myocardial 123I-BMIPP planner images were obtained 30 min (early image) and 4 h (delayed image) after tracer injection. The left ventricular ejection fraction (LVEF) was measured by quantitative gated single photon emission computed tomography. The concentration of plasma brain natriuretic peptide (BNP) was measured before the scintigraphic study. (1) Delayed H/M was much lower in CHF than in AP (1.93 +/- 0.37 vs. 2.21 +/- 0.38, p acid metabolism disorders in patients with heart disease in both masked and unmasked conditions.

  2. GAMANAL-PC: a program for gamma-ray spectrum analysis using a microcomputer

    International Nuclear Information System (INIS)

    Heimlich, M.; Beeley, P.A.; Page, J.A.

    1989-01-01

    GAMANAL was modified to operate on a microcomputer. The program uses an algorithm involving a Gaussian and a tailing term for fitting and resolving peaks obtained from spectrometers using Ge semiconductor detectors. Gamma-ray energies, intensities and absolute photon emission rates can be determined. A graphical output showing the original and fitted data can also be obtained. The results generated by the program are stored on disk as ASCII files for further analysis. This allows the use of other computer programs and languages in tasks such as decay curve analysis, radionuclide activity measurements and neutron activation analysis. (author) 11 refs.; 2 figs.; 4 tabs

  3. Measurements of gamma-ray energy deposition in a heterogeneous reactor experimental configuration and their analysis

    International Nuclear Information System (INIS)

    Calamand, D.; Wouters, R. de; Knipe, A.D.; Menil, R.

    1984-10-01

    An important contribution to the power output of a fast reactor is provided by the energy deposition from gamma-rays, and is particularly significant in the inner fertile zones of heterogeneous breeder reactor designs. To establish the validity of calculational methods and data for such systems an extensive series of measurements was performed in the zero power reactor Masurca, as part of the RACINE programme. The experimental study involved four European laboratories and the measurement techniques covered a range of thermoluminescent dosemeters and an ionization chamber. The present paper describes and compares the gamma-ray energy deposition measurements and analysis

  4. Multiple Gamma-Ray Detection Capability of a CeBr3 Detector for Gamma Spectroscopy

    Directory of Open Access Journals (Sweden)

    A. A. Naqvi

    2017-01-01

    Full Text Available The newly developed cerium tribromide (CeBr3 detector has reduced intrinsic gamma-ray activity with gamma energy restricted to 1400–2200 keV energy range. This narrower region of background gamma rays allows the CeBr3 detector to detect more than one gamma ray to analyze the gamma-ray spectrum. Use of multiple gamma-ray intensities in elemental analysis instead of a single one improves the accuracy of the estimated results. Multigamma-ray detection capability of a cylindrical 75 mm × 75 mm (diameter × height CeBr3 detector has been tested by analyzing the chlorine concentration in water samples using eight chlorine prompt gamma rays over 517 to 8578 keV energies utilizing a D-D portable neutron generator-based PGNAA setup and measuring the corresponding minimum detection limit (MDC of chlorine. The measured MDC of chlorine for gamma rays with 517–8578 keV energies varies from 0.07 ± 0.02 wt% to 0.80 ± 0.24. The best value of MDC was measured to be 0.07 ± 0.02 wt% for 788 keV gamma rays. The experimental results are in good agreement with Monte Carlo calculations. The study has shown excellent detection capabilities of the CeBr3 detector for eight prompt gamma rays over 517–8578 keV energy range without significant background interference.

  5. The Fermi All-Sky Variability Analysis: A List of Flaring Gamma-Ray Sources and the Search for Transients in our Galaxy

    Science.gov (United States)

    Ackermann, M.; Ajello, M.; Albert, A.; Allafort, A.; Antolini, E.; Baldini, L.; Ballet, J.; Barbiellini, G; Bastieri, D.; Bechtol, K.; hide

    2013-01-01

    In this paper, we present the Fermi All-sky Variability Analysis (FAVA), a tool to systematically study the variability of the gamma-ray sky measured by the Large Area Telescope on board the Fermi Gamma-ray Space Telescope.For each direction on the sky, FAVA compares the number of gamma-rays observed in a given time window to the number of gamma-rays expected for the average emission detected from that direction. This method is used in weekly time intervals to derive a list of 215 flaring gamma-ray sources. We proceed to discuss the 27 sources found at Galactic latitudes smaller than 10 and show that, despite their low latitudes, most of them are likely of extragalactic origin.

  6. Multi Elemental Study Using Prompt Gamma Technique

    International Nuclear Information System (INIS)

    Normanshah Dahing; Muhamad Samudi Yasir; Normanshah Dahing; Hanafi Ithnin; Mohd Fitri Abdul Rahman; Hearie Hassan

    2016-01-01

    In this study, principle of prompt gamma neutron activation analysis has been used as a technique to determine the elements in the sample. The system consists of collimated isotopic neutron source, Cf-252 with HPGe detector and Multichannel Analysis (MCA). Concrete with size of 10x10x10 cm 3 and 15x15x15 cm 3 were analysed as sample. When neutrons enter and interact with elements in the concrete, the neutron capture reaction will occur and produce characteristic prompt gamma ray of the elements. The preliminary result of this study demonstrate the major element in the concrete was determined such as Si, Mg, Ca, Al, Fe and H as well as others element, such as Cl by analysis the gamma ray lines respectively. The results obtained were compared with computer simulation, NAA and XRF as a part of reference and validation. The potential and the capability of neutron induced prompt gamma as tool for multi elemental analysis qualitatively to identify the elements present in the concrete sample discussed. (author)

  7. Scintigraphic evaluation of osteoblastic activity in extraction sockets treated with platelet-rich fibrin.

    Science.gov (United States)

    Gürbüzer, Bahadir; Pikdöken, Levent; Tunali, Mustafa; Urhan, Muammer; Küçükodaci, Zafer; Ercan, Feriha

    2010-05-01

    To evaluate the effect of platelet-rich fibrin (PRF) on the early bone healing process with bone scintigraphy based on technetium-99m methylene diphosphonate uptake in third molar extraction sockets. Fourteen patients with bilaterally soft tissue impacted third mandibular molars were included in the study. The right and left impacted third molars were surgically extracted in the same session. PRF was randomly administered into one of the extraction sockets, whereas the contralateral sockets were left without treatment. Four weeks after surgery, scintigrams were obtained to evaluate scintigraphic differences between PRF-treated and non-PRF-treated sockets. After completion of the clinical study, PRF samples were evaluated by light and scanning electron microscopy. The average increase in technetium-99m methylene diphosphonate uptake as an indication of enhanced bone healing did not differ significantly between PRF-treated and non-PRF-treated sockets 4 weeks postoperatively (P > .05). Abundant fibrin and inflammatory cells were observed by light microscopic examination of PRF samples. Scanning electron microscopic analysis of PRF revealed the existence of platelet aggregates in a fibrin network and crystalline particles on the outer surface of PRF. PRF might not lead to enhanced bone healing in soft tissue impacted mandibular third molar extraction sockets 4 weeks after surgery. PRF exhibits the potential characteristics of an autologous fibrin matrix. However, whether the presence of crystal-like particles on the outer surface of PRF alters bone healing should be investigated further. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Review of the Czubek--Jonas gamma-log program

    International Nuclear Information System (INIS)

    Matthews, M.

    1978-11-01

    Several gamma-ray logs were computer processed using the Czubek--Jones and DOE's MDDAT gamma-log programs. Both of these programs convert counts per second from the gamma-ray logs to percent eU 3 O 8 . The results of these programs were compared to each other and to the core analysis (percent U 3 O 8 ) of the logged boreholes. The two gamma-log programs produced similar results. The core analysis did not compare favorably with the results of either gamma-log program. This unfavorable comparison is probably due to an incorrect assumption of secular equilibrium for the ore surrounding the boreholes. The Czubek--Jonas program requires a knowledge of the linear attenuation coefficient of the rocks surrounding a borehole. This limits the usefulness of the program because this coefficient is generally not known and varies for different gamma-ray energies. It is recommended that the MDDAT program continue to be used for estimating the grade (percent eU 3 O 8 ) from gamma-log data and not be replaced by the Czubek--Jonas program

  9. Application of 111In-bleomycine in the scintigraphy of colorectal cancer

    International Nuclear Information System (INIS)

    Mladenov, B.; Peshev, N.; Minchev, D.; Tsanev, Ts.

    1990-01-01

    A gamma camera scintigraphic study of the large intestine was made of 24 patients ( 23 with colorectal cancer and 1 with abscess). 111 In-bleomycin was used. The diagnosis of all patients was verified surgically and histologically. In 88.2% of the patients a positive scintigraphic scan was obtained. Negative scintigraphic result was obtained in 2 patients with colorectal cancer localized in the ileocaecal and the transversal part of the colon. The operation showed the presence of localized tumour with 2 cm in diameter and no data for infiltration of the adjacent tissues. In the patients with benign neoplasms no accumulation of the radiopharmaceutical was registered. Positive scan was also obtained in 1 patient with post-traumatic abscess of the gluteal region. A second scanning after the conduction of appropriate anti-inflammatory therapy could be used for differentiation of the inflammations from the malignant processes. 3 figs., 5 refs

  10. Gamma radiography and its technological application

    International Nuclear Information System (INIS)

    Courtois, G.

    1962-01-01

    After the presentation of gamma radiography and X-ray radiography, the author compare both techniques showing, in particular, the greater utility of gamma radiography in industrial diagnostic and more particularly on works site diagnostic. Problem of using radiography and safety consideration will be studied. Figures shows two radiography equipment which have been designed for gamma radiography respecting the safety regulations required by the Radioisotope Inter-ministerial Commission. In the second part, different techniques and uses of gamma radiography are briefly described : xerography, neutron radiography, fluoroscopy and imaging amplifier, tomography, betatrons and linear accelerators. Cost analysis will discussed in conclusion. (M.P.)

  11. Determination of 226Ra by gamma spectrometry: study of packaging vial of sample for analysis

    International Nuclear Information System (INIS)

    Carneiro, Andre Cavalcanti

    2015-01-01

    Determination of radioactivity levels of 226 Ra by gamma spectrometry in a sample is based on measurements of 214 Pb and 214 Bi, daughters of 222 Rn. Because radon is a gas, it can leak from the sample vial or accumulate on the upper empty it. If the vial has any crack, there will be loss of gas, which will cause error in determining the 226 Ra concentration. One possible cause of cracks in the vials, that houses standards and samples, is the radiolysis action in the vial material, usually a polymer. As the demand 226 Ra analysis in different matrices (geological samples, food, plants, etc.) is increasing, it was decided to study some polymer vials available on the market, to verify the feasibility to be used when is applied the analysis method using gamma spectrometry. Four types of polymer vials have been studied. The radiation doses in walls of the vials caused by natural radionuclides present in the sample were simulated using gamma irradiation. Tests, such as compressive strength test and tightness, were applied to the irradiated and non-irradiated vials. First, to verify the effect of radiolysis on the vial material and also if there was 222 Rn diffusion in their walls. These preliminary results pointed out that the acrylic vials are the best option of packaging samples for analysis. This study should be repeated in a larger number of samples for a better evaluation. (author)

  12. The topological filtration of gamma-structures

    DEFF Research Database (Denmark)

    Li, Thomas; Reidys, Christian

    2013-01-01

    In this paper we study gamma-structures filtered by topological genus. gamma-structures are a class of RNA pseudoknot structures that plays a key role in the context of polynomial time folding of RNA pseudoknot structures. A gamma-structure is composed by specific building blocks, that have...... topological genus less than or equal to gamma, where composition means concatenation and nesting of such blocks. Our main results are the derivation of a new bivariate generating function for gamma-structures via symbolic methods, the singularity analysis of the solutions and a central limit theorem...... for the distribution of topological genus in gamma-structures of given length. In our derivation specific bivariate polynomials play a central role. Their coefficients count particular motifs of fixed topological genus and they are of relevance in the context of genus recursion and novel folding algorithms....

  13. Coincidence of scintigraphic false positive and false negative findings in parathyroid and thyroid adenomas (case report)

    Energy Technology Data Exchange (ETDEWEB)

    Mana, O.; Zatta, G.; Boccolari, S.; Barbesti, S.; Tarolo, G.L.

    1987-04-01

    The subtractive double tracer scintigraphy with /sup 201/Tl and /sup 99m/Tc is a useful technique in studying parathyroid nodules; nevertheless, this method can give misleading informations especially in presence of thyroid nodules with false positive and false negative findings. In this case report the technique was applied in studying a patient with three nodules (two thyroid adenomas and one parathyroid adenoma), where both scintigraphic and echographic methods provided misleading informations. The selective uptake of /sup 201/Tl in the upper region of the right thyroid lobe gave a false positive finding, while the increased uptake of /sup 99m/Tc in a hyperfunctioning thyroid adenoma of left lobe masked the parathyroid adenoma laying below, giving a false negative finding.

  14. Development of digital gamma-activation autoradiography for analysis of samples of large area

    International Nuclear Information System (INIS)

    Kolotov, V.P.; Grozdov, D.S.; Dogadkin, N.N.; Korobkov, V.I.

    2011-01-01

    Gamma-activation autoradiography is a prospective method for screening detection of inclusions of precious metals in geochemical samples. Its characteristics allow analysis of thin sections of large size (tens of cm2), that favourably distinguishes it among the other methods for local analysis. At the same time, the activating field of the accelerator bremsstrahlung, displays a sharp intensity decrease relative to the distance along the axis. A method for activation dose ''equalization'' during irradiation of the large size thin sections has been developed. The method is based on the usage of a hardware-software system. This includes a device for moving the sample during the irradiation, a program for computer modelling of the acquired activating dose for the chosen kinematics of the sample movement and a program for pixel-by pixel correction of the autoradiographic images. For detection of inclusions of precious metals, a method for analysis of the acquired dose dynamics during sample decay has been developed. The method is based on the software processing pixel by pixel a time-series of coaxial autoradiographic images and generation of the secondary meta-images allowing interpretation regarding the presence of interesting inclusions based on half-lives. The method is tested for analysis of copper-nickel polymetallic ores. The developed solutions considerably expand the possible applications of digital gamma-activation autoradiography. (orig.)

  15. Development of digital gamma-activation autoradiography for analysis of samples of large area

    Energy Technology Data Exchange (ETDEWEB)

    Kolotov, V.P.; Grozdov, D.S.; Dogadkin, N.N.; Korobkov, V.I. [Russian Academy of Sciences, Moscow (Russian Federation). Vernadsky Inst. of Geochemistry and Analytical Chemistry

    2011-07-01

    Gamma-activation autoradiography is a prospective method for screening detection of inclusions of precious metals in geochemical samples. Its characteristics allow analysis of thin sections of large size (tens of cm2), that favourably distinguishes it among the other methods for local analysis. At the same time, the activating field of the accelerator bremsstrahlung, displays a sharp intensity decrease relative to the distance along the axis. A method for activation dose ''equalization'' during irradiation of the large size thin sections has been developed. The method is based on the usage of a hardware-software system. This includes a device for moving the sample during the irradiation, a program for computer modelling of the acquired activating dose for the chosen kinematics of the sample movement and a program for pixel-by pixel correction of the autoradiographic images. For detection of inclusions of precious metals, a method for analysis of the acquired dose dynamics during sample decay has been developed. The method is based on the software processing pixel by pixel a time-series of coaxial autoradiographic images and generation of the secondary meta-images allowing interpretation regarding the presence of interesting inclusions based on half-lives. The method is tested for analysis of copper-nickel polymetallic ores. The developed solutions considerably expand the possible applications of digital gamma-activation autoradiography. (orig.)

  16. Gamma ray spectrum analysis code: sigmas 1.0

    International Nuclear Information System (INIS)

    Siangsanan, P.; Dharmavanij, W.; Chongkum, S.

    1996-01-01

    We have developed Sigmas 1.0 a software package for data reduction and gamma ray spectra evaluation. It is capable of analysing the gamma-ray spectrum in the range of 0-3 MeV by semiconductor detector, i.e. Ge(Li) or HPGe, peak searching, net area determining, plotting and spectrum displaying. There are two methods for calculating the net area under peaks; the Covell method and non-linear fitting by the method of Levenberg and Marquardt which can fit any multiplet peak in the spectrum. The graphic display was rather fast and user friendly

  17. Use of digital computers for correction of gamma method and neutron-gamma method indications

    International Nuclear Information System (INIS)

    Lakhnyuk, V.M.

    1978-01-01

    The program for the NAIRI-S computer is described which is intended for accounting and elimination of the effect of by-processes when interpreting gamma and neutron-gamma logging indications. By means of slight corrections it is possible to use the program as a mathematical basis for logging diagram standardization by the method of multidimensional regressive analysis and estimation of rock reservoir properties

  18. Neural network consistent empirical physical formula construction for neutron–gamma discrimination in gamma ray tracking

    International Nuclear Information System (INIS)

    Yildiz, Nihat; Akkoyun, Serkan

    2013-01-01

    Highlights: ► Detector responses in neutron–gamma discrimination were estimated by neural networks. ► Novel consistent neural network empirical physical formulas (EPFs) were constructed for detector responses. ► The EPFs are of explicit mathematical functional form. ► The EPFs can be used to derive various physical functions relevant to neutron–gamma discrimination in gamma ray tracking. -- Abstract: Gamma ray tracking is an efficient detection technique in studying exotic nuclei which lies far from beta stability line. To achieve very powerful and extraordinary resolution ability, new detectors based on gamma ray tracking are currently being developed. To reach this achievement, the neutron–gamma discrimination in these detectors is also an important task. In this paper, by suitable layered feedforward neural networks (LFNNs), we have constructed novel and consistent empirical physical formulas (EPFs) for some highly nonlinear detector counts measured in neutron–gamma discrimination. The detector counts data used in the discrimination was actually borrowed from our previous paper. The counts used here had been originally measured versus the following parameters: energy deposited in the first interaction points, difference in the incoming direction of initial gamma rays, and finally figure of merit values of the clusters determined by tracking. The LFNN–EPFs are of explicit mathematical functional form. Therefore, by various suitable operations of mathematical analysis, these LFNN–EPFs can be used to derivate further physical functions which might be potentially relevant to neutron–gamma discrimination performance of gamma ray tracking.

  19. Reaction /sup 56/Fe (. gamma. ,. cap alpha. /sub 0/) and /sup 56/Fe (. gamma. , p/sub 0/)

    Energy Technology Data Exchange (ETDEWEB)

    Tamae, T; Sugawara, M [Tohoku Univ., Sendai (Japan). Lab. of Nuclear Science; Tsubota, H

    1975-06-01

    Precise analysis was made on the cross section of the /sup 56/Fe (..gamma.., ..cap alpha../sub 0/) reaction and the angular distribution at Esub(e) = 17 MeV, including the systematic error. The (..gamma.., ..cap alpha../sub 0/) reaction cross section was compared with a calculation using the compound nucleus model, utilizing the photon absorption cross section derived from the experimental values of /sup 56/Fe (..gamma.., n) and /sup 56/Fe (..gamma.., p) cross sections. From the (..gamma.., ..cap alpha../sub 0/) reaction cross section data of various nuclei, an empirical formula was obtained for determining the position of a peak in the (..gamma.., ..cap alpha../sub 0/) reaction cross section. The /sup 56/Fe (..gamma.., p/sub 0/) reaction cross section measured at an excitation energy in the range of 14.6--25.0 MeV was compared with the calculated one with the compound nucleus model, but the form and size differ totally.

  20. Rapid, autonomous analysis of HPGe gamma-ray spectra II: Uranium identification and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Gosnell, Thomas B. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wong, Jamess L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2014-02-11

    RadID is a gamma-ray spectrum analysis program originally written to assist in the detection of the illicit movement of nuclear material. In this second of the three-document series we discuss how RadID detects the presence of uranium isotopes and determines a number of its characteristics, most notably or processed material and enriched estimates.

  1. The Analysis of RSG-GAS Spent Fuel Elements Utilization as a Gamma Irradiator

    International Nuclear Information System (INIS)

    Pudjijanto MS; Setiyanto

    2004-01-01

    A gamma irradiator using RSG-GAS spent fuels was analyzed. The cylindrical geometry of the irradiator was designed using spent fuels placed in the cylindrical periphery. The analysis especially was focused to evaluate the feasibilities of the irradiator for foods and non-foods which need not too high dose rates. While the spent fuels activities were calculated by ORIGEN2 code, the dose rates at the irradiation positions were determined by linear attenuation model with transport coefficient. The evaluated results showed that the cylindrical geometry of the irradiator with diameter around 1-1.5 m gave the effective dose rate for irradiation needs the dose rate about 2 kGy/hr. Regarding this work, it can be concluded that one can use the unutilized spent fuels effectively as a gamma irradiator for certain applications. (author)

  2. Scintigraphic measurement of regional gut transit in idiopathic constipation

    International Nuclear Information System (INIS)

    Stivland, T.; Camilleri, M.; Vassallo, M.; Proano, M.; Rath, D.; Brown, M.; Thomforde, G.; Pemberton, J.; Phillips, S.

    1991-01-01

    In this study, total gut transit and regional colonic transit in patients with idiopathic constipation were measured scintigraphically. Eight patients with severe constipation were studied, none of whom had evidence of abnormal function of the pelvic floor. 99mTc-radiolabeled Amberlite resin particles with a mixed meal were used to assess gastric emptying and small bowel transit; similar particles labeled with 111In were ingested in a coated capsule that dispersed in the ileocecal region. These were used to quantify colonic transit. Five healthy volunteers were also studied. Two patients showed delayed gastric emptying and two had slow small bowel transit. Seven of the eight patients had slow colonic transit. In five, delay affected the whole colon (pancolonic inertia); in two, transit in the ascending and transverse colon was normal, but solids moved through the left colon slowly. Mean colonic transit was also measured using radiopaque markers; this technique identified the patients with slow transit, as shown by measurements of overall colonic transit by simultaneous scintigraphy. However, estimated transit through the ascending and transverse colons was considerably shorter by the radiopaque marker technique. In conclusion, idiopathic constipation is characterized by either exaggerated reservoir functions of the ascending and transverse colons and/or impairment of propulsive function in the descending colon. Particle size may influence the result of regional colonic transit tests. Transit delays in other parts of the gut suggest that, in some patients, the condition may be a more generalized motor dysfunction

  3. Scintigraphic measurement of regional gut transit in idiopathic constipation

    Energy Technology Data Exchange (ETDEWEB)

    Stivland, T.; Camilleri, M.; Vassallo, M.; Proano, M.; Rath, D.; Brown, M.; Thomforde, G.; Pemberton, J.; Phillips, S. (Gastroenterology Research Unit, Mayo Clinic, Rochester, Minnesota (USA))

    1991-07-01

    In this study, total gut transit and regional colonic transit in patients with idiopathic constipation were measured scintigraphically. Eight patients with severe constipation were studied, none of whom had evidence of abnormal function of the pelvic floor. 99mTc-radiolabeled Amberlite resin particles with a mixed meal were used to assess gastric emptying and small bowel transit; similar particles labeled with 111In were ingested in a coated capsule that dispersed in the ileocecal region. These were used to quantify colonic transit. Five healthy volunteers were also studied. Two patients showed delayed gastric emptying and two had slow small bowel transit. Seven of the eight patients had slow colonic transit. In five, delay affected the whole colon (pancolonic inertia); in two, transit in the ascending and transverse colon was normal, but solids moved through the left colon slowly. Mean colonic transit was also measured using radiopaque markers; this technique identified the patients with slow transit, as shown by measurements of overall colonic transit by simultaneous scintigraphy. However, estimated transit through the ascending and transverse colons was considerably shorter by the radiopaque marker technique. In conclusion, idiopathic constipation is characterized by either exaggerated reservoir functions of the ascending and transverse colons and/or impairment of propulsive function in the descending colon. Particle size may influence the result of regional colonic transit tests. Transit delays in other parts of the gut suggest that, in some patients, the condition may be a more generalized motor dysfunction.

  4. Raccoon eyes and the MIBG super scan: scintigraphic signs of neuroblastoma in a case of suspected child abuse

    International Nuclear Information System (INIS)

    Bohdiewicz, P.J.; Gallegos, E.; Fink-Bennett, D.

    1995-01-01

    The authors report on an infant suspected of having been abused, who presented with periorbital edema and ecchymoses (clinial 'raccoon eyes'). The pattern of the nuclear medicine bone scan suggested neuroblastoma rather than trauma. Both the bone scan and the subsequent MIBG scan revealed multiple abnormalities, including markedly increased activity around the orbits, that we termed the 'scintigraphic raccoon eyes' sign. In addition, the grossly abnormal MIBG scan demonstrated avid uptake of MIBG throughout the entire skeleton with essentially complete absence of visualization of the liver and heart (the 'MIBG super scan'). These signs have not previously been described in an infant or a child with neuroblastoma. (orig.)

  5. Raccoon eyes and the MIBG super scan: scintigraphic signs of neuroblastoma in a case of suspected child abuse

    Energy Technology Data Exchange (ETDEWEB)

    Bohdiewicz, P.J. [Nuclear Medicine Dept., William Beaumont Hospital, Royal Oak, MI (United States); Gallegos, E. [Nuclear Medicine Dept., William Beaumont Hospital, Royal Oak, MI (United States); Fink-Bennett, D. [Nuclear Medicine Dept., William Beaumont Hospital, Royal Oak, MI (United States)

    1995-11-01

    The authors report on an infant suspected of having been abused, who presented with periorbital edema and ecchymoses (clinial `raccoon eyes`). The pattern of the nuclear medicine bone scan suggested neuroblastoma rather than trauma. Both the bone scan and the subsequent MIBG scan revealed multiple abnormalities, including markedly increased activity around the orbits, that we termed the `scintigraphic raccoon eyes` sign. In addition, the grossly abnormal MIBG scan demonstrated avid uptake of MIBG throughout the entire skeleton with essentially complete absence of visualization of the liver and heart (the `MIBG super scan`). These signs have not previously been described in an infant or a child with neuroblastoma. (orig.)

  6. Distinguishing 'Higgs' spin hypotheses using $\\gamma \\gamma$ and $W W^*$ decays

    CERN Document Server

    Ellis, John; Hwang, Dae Sung; Sanz, Veronica; You, Tevong

    2013-01-01

    The new particle X recently discovered by the ATLAS and CMS Collaborations in searches for the Higgs boson has been observed to decay into gamma gamma, ZZ* and WW*, but its spin and parity, J^P, remain a mystery, with J^P = 0^+ and 2^+ being open possibilities. We use PYTHIA and Delphes to simulate an analysis of the angular distribution of gg to X to gamma gamma decays in a full 2012 data set, including realistic background levels. We show that this angular distribution should provide strong discrimination between the possibilities of spin zero and spin two with graviton-like couplings: ~ 3 sigma if a conservative symmetric interpretation of the log-likelihood ratio (LLR) test statistic is used, and ~ 6 sigma if a less conservative asymmetric interpretation is used. The WW and ZZ couplings of the Standard Model Higgs boson and of a 2^+ particle with graviton-like couplings are both expected to exhibit custodial symmetry. We simulate the present ATLAS and CMS search strategies for X to WW* using PYTHIA and De...

  7. SAMPO 90 high resolution interactive gamma-spectrum analysis including automation with macros

    International Nuclear Information System (INIS)

    Aarnio, P.A.; Nikkinen, M.T.; Routti, J.T.

    1992-01-01

    SAMPO 90 is high performance gamma-spectrum analysis program for personal computers. It uses color graphics to display calibrations, spectra, fitting results as multiplet components, and analysis results. All the analysis phases can be done either under full interactive user control or macros and programmable function keys can be used for completely automated measurement and analysis sequences including the control of MACs and sample changers. Accurate peak area determination of even the most complex multiplets, of up to 32 components, is accomplished using linear and mixed mode fitting. Nuclide identification is done using associated lines techniques allowing interference correction for fully overlapping peaks. Peaked Background Subtraction can be performed and Minimum Detectable Activities calculated. The analysis reports and program parameters are fully customizable. (author) 13 refs.; 1 fig

  8. THE FERMI ALL-SKY VARIABILITY ANALYSIS: A LIST OF FLARING GAMMA-RAY SOURCES AND THE SEARCH FOR TRANSIENTS IN OUR GALAXY

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, M. [Deutsches Elektronen Synchrotron DESY, D-15738 Zeuthen (Germany); Ajello, M. [Space Sciences Laboratory, 7 Gauss Way, University of California, Berkeley, CA 94720-7450 (United States); Albert, A. [Department of Physics, Center for Cosmology and Astro-Particle Physics, The Ohio State University, Columbus, OH 43210 (United States); Allafort, A.; Bechtol, K.; Blandford, R. D.; Bloom, E. D.; Bottacini, E. [W. W. Hansen Experimental Physics Laboratory, Kavli Institute for Particle Astrophysics and Cosmology, Department of Physics and SLAC National Accelerator Laboratory, Stanford University, Stanford, CA 94305 (United States); Antolini, E.; Bonamente, E. [Dipartimento di Fisica, Universita degli Studi di Perugia, I-06123 Perugia (Italy); Baldini, L. [Universita di Pisa and Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Ballet, J. [Laboratoire AIM, CEA-IRFU/CNRS/Universite Paris Diderot, Service d' Astrophysique, CEA Saclay, F-91191 Gif sur Yvette (France); Barbiellini, G. [Istituto Nazionale di Fisica Nucleare, Sezione di Trieste, I-34127 Trieste (Italy); Bastieri, D. [Istituto Nazionale di Fisica Nucleare, Sezione di Padova, I-35131 Padova (Italy); Bellazzini, R.; Bregeon, J. [Istituto Nazionale di Fisica Nucleare, Sezione di Pisa, I-56127 Pisa (Italy); Bouvier, A. [Santa Cruz Institute for Particle Physics, Department of Physics and Department of Astronomy and Astrophysics, University of California at Santa Cruz, Santa Cruz, CA 95064 (United States); Brandt, T. J. [NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States); Brigida, M. [Dipartimento di Fisica ' ' M. Merlin' ' dell' Universita e del Politecnico di Bari, I-70126 Bari (Italy); Bruel, P., E-mail: majello@slac.stanford.edu, E-mail: allafort@stanford.edu, E-mail: rolf.buehler@desy.de [Laboratoire Leprince-Ringuet, Ecole polytechnique, CNRS/IN2P3, Palaiseau (France); and others

    2013-07-01

    In this paper, we present the Fermi All-sky Variability Analysis (FAVA), a tool to systematically study the variability of the gamma-ray sky measured by the Large Area Telescope on board the Fermi Gamma-ray Space Telescope. For each direction on the sky, FAVA compares the number of gamma-rays observed in a given time window to the number of gamma-rays expected for the average emission detected from that direction. This method is used in weekly time intervals to derive a list of 215 flaring gamma-ray sources. We proceed to discuss the 27 sources found at Galactic latitudes smaller than 10 Degree-Sign and show that, despite their low latitudes, most of them are likely of extragalactic origin.

  9. THE FERMI ALL-SKY VARIABILITY ANALYSIS: A LIST OF FLARING GAMMA-RAY SOURCES AND THE SEARCH FOR TRANSIENTS IN OUR GALAXY

    International Nuclear Information System (INIS)

    Ackermann, M.; Ajello, M.; Albert, A.; Allafort, A.; Bechtol, K.; Blandford, R. D.; Bloom, E. D.; Bottacini, E.; Antolini, E.; Bonamente, E.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bellazzini, R.; Bregeon, J.; Bouvier, A.; Brandt, T. J.; Brigida, M.; Bruel, P.

    2013-01-01

    In this paper, we present the Fermi All-sky Variability Analysis (FAVA), a tool to systematically study the variability of the gamma-ray sky measured by the Large Area Telescope on board the Fermi Gamma-ray Space Telescope. For each direction on the sky, FAVA compares the number of gamma-rays observed in a given time window to the number of gamma-rays expected for the average emission detected from that direction. This method is used in weekly time intervals to derive a list of 215 flaring gamma-ray sources. We proceed to discuss the 27 sources found at Galactic latitudes smaller than 10° and show that, despite their low latitudes, most of them are likely of extragalactic origin.

  10. Optimisation of beryllium-7 gamma analysis following BCR sequential extraction

    International Nuclear Information System (INIS)

    Taylor, A.; Blake, W.H.; Keith-Roach, M.J.

    2012-01-01

    Graphical abstract: Showing decrease in analytical uncertainty using the optimal (combined preconcentrated sample extract) method. nv (no value) where extract activities were 7 Be geochemical behaviour is required to support tracer studies. ► Sequential extraction with natural 7 Be returns high analytical uncertainties. ► Preconcentrating extracts from a large sample mass improved analytical uncertainty. ► This optimised method can be readily employed in studies using low activity samples. - Abstract: The application of cosmogenic 7 Be as a sediment tracer at the catchment-scale requires an understanding of its geochemical associations in soil to underpin the assumption of irreversible adsorption. Sequential extractions offer a readily accessible means of determining the associations of 7 Be with operationally defined soil phases. However, the subdivision of the low activity concentrations of fallout 7 Be in soils into geochemical fractions can introduce high gamma counting uncertainties. Extending analysis time significantly is not always an option for batches of samples, owing to the on-going decay of 7 Be (t 1/2 = 53.3 days). Here, three different methods of preparing and quantifying 7 Be extracted using the optimised BCR three-step scheme have been evaluated and compared with a focus on reducing analytical uncertainties. The optimal method involved carrying out the BCR extraction in triplicate, sub-sampling each set of triplicates for stable Be analysis before combining each set and coprecipitating the 7 Be with metal oxyhydroxides to produce a thin source for gamma analysis. This method was applied to BCR extractions of natural 7 Be in four agricultural soils. The approach gave good counting statistics from a 24 h analysis period (∼10% (2σ) where extract activity >40% of total activity) and generated statistically useful sequential extraction profiles. Total recoveries of 7 Be fell between 84 and 112%. The stable Be data demonstrated that the

  11. Routine studies of swallowed radionuclide transit in pediatrics: experience with 400 patients

    Energy Technology Data Exchange (ETDEWEB)

    Guillet, J.; Basse-Cathalinat, B.; Christophe, E.; Blanquet, P.; Ducassou, D.; Wynchank, S.

    1984-02-01

    Scintigraphic studies of swallowed 99m Tc-sulphur colloid mixed with a few millilitres of liquid, performed on 400 pediatric patients of all ages, allowed visualisation of foregut function and measurement of oesophageal transit time and gastric emptying proportions. This non-invasive and physiological procedure requires a standard gamma camera with computing facilities and was performed as an outpatient routine. It proved very effective for the detection of gastro-oesophageal reflux and aspiration of refluxed liquid in patients of all ages but especially in neonates. The relevance of these scintigraphic results to oesophagitis, repeated respiratory problems, cyanotic and apnoeic spells and alternative methods of investigation is described.

  12. Routine studies of swallowed radionuclide transit in paediatrics: experience with 400 patients

    International Nuclear Information System (INIS)

    Guillet, J.; Basse-Cathalinat, B.; Christophe, E.; Blanquet, P.; Wynchank, S.

    1984-01-01

    Scintigraphic studies of swallowed 99 m Tc-sulphur colloid mixed with a few millilitres of liquid, performed on 400 paediatric patients of all ages, allowed visualisation of foregut function and measurement of oesophageal transit time and gastric emptying proportions. This non-invasive and physiological procedure requires a standard gamma camera with computing facilities and was performed as an outpatient routine. It proved very effective for the detection of gastro-oesophageal reflux and aspiration of refluxed liquid in patients of all ages but especially in neonates. The relevance of these scintigraphic results to oesophagitis, repeated respiratory problems, cyanotic and apnoeic spells and alternative methods of investigation is described. (orig.)

  13. Performance Analysis of Polarization Modulated DirectDetection Optical CDMA Systems over Turbulent FSO LinksModeled by the Gamma-Gamma Distribution

    Directory of Open Access Journals (Sweden)

    Fan Bai

    2015-01-01

    Full Text Available This paper proposes a theoretical study to characterize the transmission of optical code division multiple access (CDMA systems deploying polarization shift keying (PolSK over a free space optical (FSO link under the impact of atmospheric turbulence. In our analysis, a novel transceiver architecture for atmospheric OCDMA FSO systems based on polarization modulation with direct detection is proposed and discussed. A detailed analytical model for PolSK-OCDMA systems over a turbulent FSO link is provided. Further, we derive a closed-form bit error ratio (BER and outage probability expressions, taking into account the multiple-access interference (MAI, optical noise and the atmospheric turbulence effect on the FSO link modeled by the Gamma-Gamma distribution. Finally, the results of this study show the most significant parameters that degrade the transmission performance of the PolSK-OCDMA signal over FSO links and indicate that the proposed approach offers improved bit error ratio (BER performances compared to the on-off-keying (OOK modulation scheme in the presence of turbulence.

  14. Modification of the labelling autologous erythrocytes with Tc-99m to scintigraphic evaluation of deep vein system

    International Nuclear Information System (INIS)

    Quintero, C.M.; Freire, D.Y.

    1993-01-01

    The purpose of this was the modification of labelled autologous red blood cells in vivo/in vitro. Evaluation consisted in different combinations of Tc-99m radiopharmaceuticals as pyrophosphate (PYP) and stannous chloride (SnCl2), anticoagulants as heparin and acid-citrate-dextrose (ACD), and oxidant agents as hydrogen peroxide (H2O2) and sodium hypochlorite (NaClO); factorial block design was carried out to determinate which one brings a better yield of labelling, and more advantages of availability. Results showed that all tested combinations were above 90% labelled; variance analysis indicated significant difference between the two radiopharmaceuticals (P<0.05), being higher percent of labelling with PYP than SnCl2, and PYP-ACD-NaClO the best combination. It was demonstrated that the procedure is safe because hemocultives realized during the labelling process were all negative, evidencing no bacterial contamination. There were significant erythrocyte-shape modifications, too. Due to low costs and good availability of H2O2 as oxidant agent there were no statistic significant differences between the use of H2O2 or NaClO, the modification PYP-ACD-H2O2 will be used as scintigraphic test for deep vein thrombosis

  15. Development and gamma-scintigraphy study of Hibiscus rosasinensis polysaccharide-based microspheres for nasal drug delivery.

    Science.gov (United States)

    Sharma, Nitin; Tyagi, Shanu; Gupta, Satish Kumar; Kulkarni, Giriraj Thirupathirao; Bhatnagar, Aseem; Kumar, Neeraj

    2016-11-01

    This work describes the application of natural plant polysaccharide as pharmaceutical mucoadhesive excipients in delivery systems to reduce the clearance rate through nasal cavity. Novel natural polysaccharide (Hibiscus rosasinensis)-based mucoadhesive microspheres were prepared by using emulsion crosslinking method for the delivery of rizatriptan benzoate (RB) through nasal route. Mucoadhesive microspheres were characterized for different parameters and nasal clearance of technetium-99m ((99m)Tc)-radiolabeled microspheres was determined by using gamma-scintigraphy. Their Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction (XRD) studies showed that the drug was stable during preparation of microspheres. Aerodynamic diameter of microspheres was in the range 13.23 ± 1.83-33.57 ± 3.69 µm. Change in drug and polysaccharide ratio influenced the mucoadhesion, encapsulation efficiency and in-vitro release property. Scintigraphs taken at regular interval indicate that control solution was cleared rapidly from nasal cavity, whereas microspheres showed slower clearance (p < 0.005) with half-life of 160 min. Natural polysaccharide-based microspheres achieved extended residence by minimizing effect of mucociliary clearance with opportunity of sustained delivery for longer duration.

  16. Near stellar sources of gamma-ray bursts

    OpenAIRE

    Luchkov, B. I.; Markin, P. D.

    2012-01-01

    Correlation analysis of gamma-ray burst coordinates and nearby stars, registered on 2008-2011, revealed 5 coincidences with angular accuracy better than 0.1 degree. The random probability is $7\\times 10^{-7}$, so evidencing that coincident stars are indeed gamma-ray burst sources. The proposed method should be continued in order to provide their share in common balance of cosmic gamma-ray bursts.

  17. Molecular analysis of point mutations in a barley genome exposed to MNU and gamma rays

    Energy Technology Data Exchange (ETDEWEB)

    Kurowska, Marzena, E-mail: mkurowsk@us.edu.pl [Department of Genetics, Faculty of Biology and Environmental Protection, University of Silesia, Jagiellonska 28, 40-032 Katowice (Poland); Labocha-Pawlowska, Anna; Gnizda, Dominika; Maluszynski, Miroslaw; Szarejko, Iwona [Department of Genetics, Faculty of Biology and Environmental Protection, University of Silesia, Jagiellonska 28, 40-032 Katowice (Poland)

    2012-10-15

    We present studies aimed at determining the types and frequencies of mutations induced in the barley genome after treatment with chemical (N-methyl-N-nitrosourea, MNU) and physical (gamma rays) mutagens. We created M{sub 2} populations of a doubled haploid line and used them for the analysis of mutations in targeted DNA sequences and over an entire barley genome using TILLING (Targeting Induced Local Lesions in Genomes) and AFLP (Amplified Fragment Length Polymorphism) technique, respectively. Based on the TILLING analysis of the total DNA sequence of 4,537,117 bp in the MNU population, the average mutation density was estimated as 1/504 kb. Only one nucleotide change was found after an analysis of 3,207,444 bp derived from the highest dose of gamma rays applied. MNU was clearly a more efficient mutagen than gamma rays in inducing point mutations in barley. The majority (63.6%) of the MNU-induced nucleotide changes were transitions, with a similar number of G > A and C > T substitutions. The similar share of G > A and C > T transitions indicates a lack of bias in the repair of O{sup 6}-methylguanine lesions between DNA strands. There was, however, a strong specificity of the nucleotide surrounding the O{sup 6}-meG at the -1 position. Purines formed 81% of nucleotides observed at the -1 site. Scanning the barley genome with AFLP markers revealed ca. a three times higher level of AFLP polymorphism in MNU-treated as compared to the gamma-irradiated population. In order to check whether AFLP markers can really scan the whole barley genome for mutagen-induced polymorphism, 114 different AFLP products, were cloned and sequenced. 94% of bands were heterogenic, with some bands containing up to 8 different amplicons. The polymorphic AFLP products were characterised in terms of their similarity to the records deposited in a GenBank database. The types of sequences present in the polymorphic bands reflected the organisation of the barley genome.

  18. Tomography by positrons: methodology and applications

    International Nuclear Information System (INIS)

    Kellershohn, C.; Comar, D.

    1979-01-01

    Whereas gamma tomography (single photon) provides a new and fruitful dimension to conventional nuclear medicine, tomography by positrons makes possible a novel approach to the in-vivo analysis of fundamental and biological processes. The main object of both is the cross sectional representation of the distribution of a radioactive marker injected into the organism and in comparison with conventional detectors (gamma cameras and scintigraphs) they afford a much improved accuracy in position finding. The characteristics of these two methods may be represented diagrammatically by comparing their respective advantages and drawbacks. The method of fabricating positron emitting radioelements, the preparation of the radopharmeutics and the detection appliances are then examined in turn. To conclude, the medical uses: anatomical autoradiographs, as well as physiological, metabolic and pharmacological autoradiographs are described [fr

  19. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    Energy Technology Data Exchange (ETDEWEB)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M., E-mail: mlpena@sgc.gov.co; Orozco, J. [Colombian Geological Survey, Nuclear Affairs Technical Division, Neutron Activation Analysis Laboratory, Bogota D. C. (Colombia)

    2016-07-07

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  20. Association of bone scintigraphic abnormalities with knee malalignment and pain.

    Science.gov (United States)

    Kraus, V B; McDaniel, G; Worrell, T W; Feng, S; Vail, T P; Varju, G; Coleman, R E

    2009-11-01

    The information content of knee bone scintigraphy was evaluated, including pattern, localisation and intensity of retention relative to radiographic features of knee osteoarthritis, knee alignment and knee symptoms. A total of 308 knees (159 subjects) with symptomatic and radiographic knee osteoarthritis of at least one knee was assessed by late-phase (99m)Technetium methylene disphosphonate bone scintigraph, fixed-flexion knee radiograph, full limb radiograph for knee alignment and for self-reported knee symptom severity. Generalised linear models were used to control for within-subject correlation of knee data. The compartmental localisation (medial vs lateral) and intensity of knee bone scan retention were associated with the pattern (varus vs valgus) (p<0.001) and severity (p<0.001) of knee malalignment and localisation and severity of radiographic osteoarthritis (p<0.001). Bone scan agent retention in the tibiofemoral, but not patellofemoral, compartment was associated with severity of knee symptoms (p<0.001) and persisted after adjusting for radiographic osteoarthritis (p<0.001). To the authors' knowledge, this is the first study describing a relationship between knee malalignment, joint symptom severity and compartment-specific abnormalities by bone scintigraphy. This work demonstrates that bone scintigraphy is a sensitive and quantitative indicator of symptomatic knee osteoarthritis. Used selectively, bone scintigraphy is a dynamic imaging modality that holds great promise as a clinical trial screening tool and outcome measure.

  1. Analysis of proposed gamma-ray detection system for the monitoring of core water inventory in a pressurized water reactor

    International Nuclear Information System (INIS)

    Markoff, D.M.

    1987-12-01

    An initial study has been performed of the feasibility of employing an axial array of gamma detectors located outside the pressure vessel to monitor the coolant in a PWR. A one-dimensional transport analysis model is developed for the LOFT research reactor and for a mock-PWR geometry. The gamma detector response to coolant voiding in the core and downcomer has been determined for both geometries. The effects of various conditions (for example, time after shutdown, materials in the transport path, and the relative void fraction in different water regions) on the detector response are studied. The calculational results have been validated by a favorable comparison with LOFT experimental data. Within the limitations and approximations considered in the analysis, the results indicate that the gamma-ray detection scheme is able to unambiguously respond to changes in the coolant inventory within any vessel water region

  2. The use of combined three-dimensional electron backscatter diffraction and energy dispersive X-ray analysis to assess the characteristics of the gamma/gamma-prime microstructure in alloy 720Li™

    International Nuclear Information System (INIS)

    Child, D.J.; West, G.D.; Thomson, R.C.

    2012-01-01

    Multiple three-dimensional reconstructions of a γ/γ′ phase structure in Alloy 720Li have been carried out by employing a serial milling technique with simultaneous electron backscatter diffraction (EBSD) and energy dispersive x-ray (EDX) analysis data collection. Combining EBSD data with EDX is critical in obtaining maps to distinguish between the chemically differing, but crystallographically similar γ and γ′ phases present in the alloy studied. EDX is shown to allow the differentiation of γ and γ′ phases, with EBSD providing increased grain shape accuracy. The combination of data sources also allowed identification of coherent γ/γ′ phase interfaces that would not be identified using solely EBSD or EDX. The study identifies a region of grain banding within the alloy, which provides the basis for a three-dimensional comparison and discussion of γ′ phase size between coarse and fine grain regions, whilst also identifying coherent γ′ phase interfaces, possible only using both EDX and EBSD systems simultaneously. The majority of the γ′ phase lies in the range of 1–10 μm in non-banded regions, with a detectable particle size limit of 500 nm being established. The validity of the reconstruction has been demonstrated using an electron interaction volumes model, and an assessment of the validity of EBSD and EDX data sources is discussed showing γ′ phase connectivity in all dimensions. -- Highlights: ► Use of combined EBSD/EDX for the 3D analysis of gamma prime in a Ni-based alloy. ► Assessment of 3D reconstruction accuracy using CASINO. ► Observation and validation of gamma prime phase connectivity throughout the alloy. ► Identification and characterisation of grain banding in gamma prime. ► Distinction of phase coherency between gamma and gamma prime.

  3. Determination of U, Th and K in bricks by gamma -ray spectrometry, X-ray fluorescence analysis and neutron activation analysis

    Czech Academy of Sciences Publication Activity Database

    Bártová, H.; Kučera, Jan; Musílek, L.; Trojek, T.; Gregorová, E.

    2017-01-01

    Roč. 140, NOV (2017), s. 161-166 ISSN 0969-806X R&D Projects: GA MŠk LM2015056 Institutional support: RVO:61389005 Keywords : Gamma-ray spectrometry * neutron activation analysis * environmental dosimetry Subject RIV: CB - Analytical Chemistry , Separation OBOR OECD: Analytical chemistry Impact factor: 1.315, year: 2016

  4. Proximal gamma-ray spectroscopy to predict soil properties using windows and full-spectrum analysis methods.

    Science.gov (United States)

    Mahmood, Hafiz Sultan; Hoogmoed, Willem B; van Henten, Eldert J

    2013-11-27

    Fine-scale spatial information on soil properties is needed to successfully implement precision agriculture. Proximal gamma-ray spectroscopy has recently emerged as a promising tool to collect fine-scale soil information. The objective of this study was to evaluate a proximal gamma-ray spectrometer to predict several soil properties using energy-windows and full-spectrum analysis methods in two differently managed sandy loam fields: conventional and organic. In the conventional field, both methods predicted clay, pH and total nitrogen with a good accuracy (R2 ≥ 0.56) in the top 0-15 cm soil depth, whereas in the organic field, only clay content was predicted with such accuracy. The highest prediction accuracy was found for total nitrogen (R2 = 0.75) in the conventional field in the energy-windows method. Predictions were better in the top 0-15 cm soil depths than in the 15-30 cm soil depths for individual and combined fields. This implies that gamma-ray spectroscopy can generally benefit soil characterisation for annual crops where the condition of the seedbed is important. Small differences in soil structure (conventional vs. organic) cannot be determined. As for the methodology, we conclude that the energy-windows method can establish relations between radionuclide data and soil properties as accurate as the full-spectrum analysis method.

  5. Influence of the temperature in the measurement of the gamma automatic probe Gamma Tracer

    International Nuclear Information System (INIS)

    Caveda R, C.A.; Dominguez L, O.; Alonso A, D.; Montalvan E, A.; Fabelo B, O.

    2006-01-01

    In the following work an analysis of the existent relationship among the measurement of the absorbed dose rate in air due to the environmental gamma radiation and the temperature, magnitudes measured to intervals of 10 minutes by the gamma probe Gamma Tracer located in the post of occident of the National Net of Environmental Radiological Surveillance (RNVRA), in the Center of Protection and Hygiene of the Radiations (CPHR) is made. For it its were analyzed near 100,000 measurements corresponding to the period 2004-2005. For a better processing and interpretation of the data, these were analyzed with one frequency time zone and monthly using the Gamma Red software to which was necessary to add it some options. Finally it was submitted the probe to a heating process inside a stove. The results of the carried out experiments confirmed that the absorbed dose rate in air due to the environmental gamma radiation depends potentially of the probe temperature in the range of environmental temperature to which is subjected daily the same one. (Author)

  6. Correlative Spectral Analysis of Gamma-Ray Bursts using Swift-BAT and GLAST-GBM

    International Nuclear Information System (INIS)

    Stamatikos, Michael; Sakamoto, Taka; Band, David L.

    2008-01-01

    We discuss the preliminary results of spectral analysis simulations involving anticipated correlated multi-wavelength observations of gamma-ray bursts (GRBs) using Swift's Burst Alert Telescope (BAT) and the Gamma-Ray Large Area Space Telescope's (GLAST) Burst Monitor (GLAST-GBM), resulting in joint spectral fits, including characteristic photon energy (E peak ) values, for a conservative annual estimate of ∼30 GRBs. The addition of BAT's spectral response will (i) complement in-orbit calibration efforts of GBM's detector response matrices, (ii) augment GLAST's low energy sensitivity by increasing the ∼20-100 keV effective area, (iii) facilitate ground-based follow-up efforts of GLAST GRBs by increasing GBM's source localization precision, and (iv) help identify a subset of non-triggered GRBs discovered via off-line GBM data analysis. Such multi-wavelength correlative analyses, which have been demonstrated by successful joint-spectral fits of Swift-BAT GRBs with other higher energy detectors such as Konus-WIND and Suzaku-WAM, would enable the study of broad-band spectral and temporal evolution of prompt GRB emission over three energy decades, thus potentially increasing science return without placing additional demands upon mission resources throughout their contemporaneous orbital tenure over the next decade.

  7. Correlative Spectral Analysis of Gamma-Ray Bursts using Swift-BAT and GLAST-GBM

    International Nuclear Information System (INIS)

    Stamatikos, Michael; Sakamoto, Takanori; Band, David L.

    2008-01-01

    We discuss the preliminary results of spectral analysis simulations involving anticipated correlated multi-wavelength observations of gamma-ray bursts (GRBs) using Swift's Burst Alert Telescope (BAT) and the Gamma-Ray Large Area Space Telescope's (GLAST) Burst Monitor (GLAST-GBM), resulting in joint spectral fits, including characteristic photon energy (E peak ) values, for a conservative annual estimate of ∼30 GRBs. The addition of BAT/s spectral response will (i) complement in-orbit calibration efforts of GBM's detector response matrices, (ii) augment GLAST's low energy sensitivity by increasing the ∼20-100 keV effective area, (iii) facilitate ground-based follow-up efforts of GLAST GRBs by increasing GBM's source localization precision, and (iv) help identify a subset of non-triggered GRBs discovered via off-line GBM data analysis. Such multi-wavelength correlative analyses, which have been demonstrated by successful joint-spectral fits of Swift-BAT GRBs with other higher energy detectors such as Konus-WIND and Suzaku-WAM, would enable the study of broad-band spectral and temporal evolution of prompt GRB emission over three energy decades, thus potentially increasing science return without placing additional demands upon mission resources throughout their contemporaneous orbital tenure over the next decade

  8. Prompt gamma-ray spectroscopy and its use for the elemental chemical analysis

    International Nuclear Information System (INIS)

    Deconninck, G.; Demortier, G.; Bodart, F.

    The elemental chemical analysis by nuclear techniques has been widely developed since a quarter of century. In this review the analysis by irradiation of the the sample (solid or liquid) of a majority of chemical elements by means of the charged particles and the detection during this irradiation of the gamma photons characteristic of the element are considered. After a brief account of the physical phenomena peculiar to the prompt detection of photons in comparison with the activation methods where a delayed activity is measured, a brief description of the experimental equipment for this kind of analysis is given. A comprehensive critical survey of the recent applications to the analysis of metals, semiconductors and electric insulating substances is presented. The necessary informations for the choice of the nuclear reaction to use for a specific analysis are contained in a set of tables. (AF)

  9. Automatic gamma spectrometry analytical apparatus

    International Nuclear Information System (INIS)

    Lamargot, J.-P.; Wanin, Maurice.

    1980-01-01

    This invention falls within the area of quantitative or semi-quantitative analysis by gamma spectrometry and particularly refers to a device for bringing the samples into the counting position. The purpose of this invention is precisely to provide an automatic apparatus specifically adapted to the analysis of hard gamma radiations. To this effect, the invention relates to a gamma spectrometry analytical device comprising a lead containment, a detector of which the sensitive part is located inside the containment and additionally comprising a transfer system for bringing the analyzed samples in succession to a counting position inside the containment above the detector. A feed compartment enables the samples to be brought in turn one by one on to the transfer system through a duct connecting the compartment to the transfer system. Sequential systems for the coordinated forward feed of the samples in the compartment and the transfer system complete this device [fr

  10. A paper sheet phantom for scintigraphic planar imaging. Usefulness of pouch-laminated paper source

    International Nuclear Information System (INIS)

    Takaki, Akihiro; Soma, Tsutomu; Murase, Kenya; Teraoka, Satomi; Murakami, Tomonori; Kojima, Akihiro; Matsumoto, Masanori

    2007-01-01

    In order to perform experimental measurements for evaluation of imaging device's performance, data acquisition technique, and clinical images on scintigraphic imaging, many kinds of phantoms are employed. However, since these materials are acrylic and plastic, the thickness and quality of those materials cause attenuation and scatter in itself. We developed a paper sheet phantom sealed with a pouch laminator, which can be a true radioactive source in air. In this study, the paper sheet phantom was compared to the acrylic liver phantom, with the thickness of 2 cm, which is commercially available. The results showed that although some scatter counts were contained within the image of the acrylic liver phantom, there were few scattered photons in the paper sheet phantom image. Furthermore, this laminated paper sheet phantom made handling of the source and its waste easier. If the paper sheet phantom will be designed more sophisticatedly, it becomes a useful tool for planar imaging experiments. (author)

  11. Scintigraphic evaluation of chronic cholecystitis with cholelithiasis using technetium-99m-labelled pyridoxylidene isoleucine

    International Nuclear Information System (INIS)

    Alp, E.; Bekdik, C.F.; Laleli, Y.; Ercan, M.T.

    1981-01-01

    Technetium-99m-labelled pyridoxylidene isoleucine was evaluated in normal subjects as a hepatobiliar scanning agent and in patients with chronic cholecystitis with cholelithiasis. In all the normals and patients the liver function tests (SGOT, SGPT, AP and serum bilirubin) were normal. Scintigraphic studies were performed at 5, 10, 15, 20, 25, 30 and 60 min after IV administration of the agent. In the normal group (seven subjects) liver was visualized at 5 min, the common bile duct and the gall bladder at 5-15 min and the bowel activity within 20 min. In the patient group (15 subjects) the liver and the common bile duct were visualized at the same time as in the normal group but the gall bladder was either visualized later or not at all. The results showed that chronic cholecystitis with cholelithiasis may be diagnosed with 87% accuracy using 99 Tcsup(m)-pyridoxylidene isoleucine cholescintigraphy. Scintigraphy with this agent has also superiority over roentgenologic examination in 20% of the cases. (author)

  12. Clinical, radiographic and scintigraphic aspects of the trapeziometacarpal osteoarthritis; Caracterizacao clinica, radiografica e cintilografica da osteoartrose trapeziometacarpiana

    Energy Technology Data Exchange (ETDEWEB)

    Kaziyama, Helena Hideko Seguchi

    1996-12-31

    Trapeziometacarpal osteoarthritis occurs mainly in women during the menopausal period. It is related to manual activities and is usually bilateral. The onset is insidious and the evolution is slow and progressive. It is characterized by of strength and pain in the basis of the thumb resulting in limitation of the use and function of the hand. The diagnosis of this condition is based on the physical examination. The manouver of compression axial-rotation of the trapezimetacarpal joint is a common positive finding. Typical findings of osteoarthritis are present in the radiological studies. Scintigraphic images have a predictive value. The early diagnosis is important to avoid the risk factors and to prevent disabilities of the hand. (author) 102 refs., 18 figs., 10 tabs.

  13. Clinical, radiographic and scintigraphic aspects of the trapeziometacarpal osteoarthritis; Caracterizacao clinica, radiografica e cintilografica da osteoartrose trapeziometacarpiana

    Energy Technology Data Exchange (ETDEWEB)

    Kaziyama, Helena Hideko Seguchi

    1997-12-31

    Trapeziometacarpal osteoarthritis occurs mainly in women during the menopausal period. It is related to manual activities and is usually bilateral. The onset is insidious and the evolution is slow and progressive. It is characterized by of strength and pain in the basis of the thumb resulting in limitation of the use and function of the hand. The diagnosis of this condition is based on the physical examination. The manouver of compression axial-rotation of the trapezimetacarpal joint is a common positive finding. Typical findings of osteoarthritis are present in the radiological studies. Scintigraphic images have a predictive value. The early diagnosis is important to avoid the risk factors and to prevent disabilities of the hand. (author) 102 refs., 18 figs., 10 tabs.

  14. Application of the similitude principle to gamma-gamma density measurements; Application du principe de similitude a la mesure gamma-gamma de densite

    Energy Technology Data Exchange (ETDEWEB)

    Czubek, J A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement d' Electronique Generale, Service d' Electronique Industrielle; Institut de Recherches Nucleaires, Dep. VI, Cracow (Poland)

    1966-07-01

    The work presented here deals with the problem of the application of the similitude principle to rock density measurements by the gamma-gamma method. A formula is presented which makes it possible to transform results of gamma-gamma measurements carried out on models in order to make them suitable for comparison with results obtained under actual field conditions. Both the space coordinates and the densities are transformed. This transformation makes it possible to obtain a calibration curve as a function of the density for a gamma-gamma probe using only a single model of given density. The influence has also been studied of the chemical composition on the results obtained from gamma-gamma measurements. A method has been developed for estimating the equivalent Z parameter of the medium; the possibility of completely eliminating the influence of the chemical composition of the medium on the measurement results has been studied. (author) [French] L'etude presentee ci-dessous traite le probleme de l'application du principe de similitude aux mesures de densite des roches par la methode gamma-gamma. Nous indiquons une formule qui permet de transformer les resultats des mesures gamma-gamma effectuees sur les modeles pour les comparer aux resultats obtenus dans les conditions reelles sur le terrain. On transforme les coordonnees spatiales ainsi que les densites. Cette transformation donne la possibilite d'obtenir une courbe d'etalonnage (en fonction de la densite) pour une sonde gamma-gamma en utilisant un seul modele de densite donnee. On a etudie aussi l'influence de la composition chimique sur les resultats obtenus des mesures gamma-gamma. On a etabli une methode d'estimation du parametre Z equivalent du milieu, ainsi que la possibilite d'eliminer completement l'influence de la composition chimique du milieu sur les resultats des mesures de densite. (auteur)

  15. Determination of gamma production from (n, gamma) reactions

    International Nuclear Information System (INIS)

    Kostal, M.

    2007-06-01

    Calculation of gamma production by interaction of neutrons with materials requires a reasonable accuracy of the nuclear libraries, i. e. effective cross sections, nuclear levels and probabilities of transitions between them. Accurate data enable accurate calculations to be performed, e.g. for PGNAA. First, gamma production in a thick 56 Fe target was examined. Appreciable discrepancies were found among the nuclear libraries available. Additional calculations were performed and compared with the observed data. The fluence of photons observed behind a thick iron target was investigated, the target being irradiated with neutrons from the front side. The results were evaluated for the various nuclear libraries. It is concluded that the libraries ENDF/B VI.2., i.e. data embedded in the MCNPX code, are sufficient for a number of applications. However, their accuracy is insufficient for prompt gamma neutron activation analysis. This is also true of data from the libraries JEFF 3.1. a JENDL 3.3, so that other libraries will have to be used for PGNAA. Specifically for 56 Fe, the data from the libraries ENDF/B VII.0 seem to be usable. (P.A.)

  16. The gamma knife: Dose and risk evaluation

    International Nuclear Information System (INIS)

    Jones, E.D.; Alesso, H.P.; Banks, W.W.; Rathbun, P.A.

    1992-01-01

    This paper outlines a risk analysis approach designed to identify and assess most likely failure modes and high-risk, human initiated actions for nuclear medical devices. This approach is being developed under the auspices of the US Nuclear Regulatory Commission, Office of Nuclear Material Safety and Safeguards. The methodology is initiated intended to assess risk associated with the use of the Leksell Gamma Unit (LGU) or gamma knife, a gamma stereotactic radiosurgical device

  17. Use of new spectral analysis methods in gamma spectra deconvolution

    International Nuclear Information System (INIS)

    Pinault, J.L.

    1991-01-01

    A general deconvolution method applicable to X and gamma ray spectrometry is proposed. Using new spectral analysis methods, it is applied to an actual case: the accurate on-line analysis of three elements (Ca, Si, Fe) in a cement plant using neutron capture gamma rays. Neutrons are provided by a low activity (5 μg) 252 Cf source; the detector is a BGO 3 in.x8 in. scintillator. The principle of the methods rests on the Fourier transform of the spectrum. The search for peaks and determination of peak areas are worked out in the Fourier representation, which enables separation of background and peaks and very efficiently discriminates peaks, or elements represented by several peaks. First the spectrum is transformed so that in the new representation the full width at half maximum (FWHM) is independent of energy. Thus, the spectrum is arranged symmetrically and transformed into the Fourier representation. The latter is multiplied by a function in order to transform original Gaussian into Lorentzian peaks. An autoregressive filter is calculated, leading to a characteristic polynomial whose complex roots represent both the location and the width of each peak, provided that the absolute value is lower than unit. The amplitude of each component (the area of each peak or the sum of areas of peaks characterizing an element) is fitted by the weighted least squares method, taking into account that errors in spectra are independent and follow a Poisson law. Very accurate results are obtained, which would be hard to achieve by other methods. The DECO FORTRAN code has been developed for compatible PC microcomputers. Some features of the code are given. (orig.)

  18. Classification of soil samples according to their geographic origin using gamma-ray spectrometry and principal component analysis

    International Nuclear Information System (INIS)

    Dragovic, Snezana; Onjia, Antonije

    2006-01-01

    A principal component analysis (PCA) was used for classification of soil samples from different locations in Serbia and Montenegro. Based on activities of radionuclides ( 226 Ra, 238 U, 235 U, 4 K, 134 Cs, 137 Cs, 232 Th and 7 Be) detected by gamma-ray spectrometry, the classification of soils according to their geographical origin was performed. Application of PCA to our experimental data resulted in satisfactory classification rate (86.0% correctly classified samples). The obtained results indicate that gamma-ray spectrometry in conjunction with PCA is a viable tool for soil classification

  19. Risk analysis of Leksell Gamma Knife Model C with automatic positioning system

    International Nuclear Information System (INIS)

    Goetsch, Steven J.

    2002-01-01

    Purpose: This study was conducted to evaluate the decrease in risk from misadministration of the new Leksell Gamma Knife Model C with Automatic Positioning System compared with previous models. Methods and Materials: Elekta Instruments, A.B. of Stockholm has introduced a new computer-controlled Leksell Gamma Knife Model C which uses motor-driven trunnions to reposition the patient between isocenters (shots) without human intervention. Previous models required the operators to manually set coordinates from a printed list, permitting opportunities for coordinate transposition, incorrect helmet size, incorrect treatment times, missing shots, or repeated shots. Results: A risk analysis was conducted between craniotomy involving hospital admission and outpatient Gamma Knife radiosurgery. A report of the Institute of Medicine of the National Academies dated November 29, 1999 estimated that medical errors kill between 44,000 and 98,000 people each year in the United States. Another report from the National Nosocomial Infections Surveillance System estimates that 2.1 million nosocomial infections occur annually in the United States in acute care hospitals alone, with 31 million total admissions. Conclusions: All medical procedures have attendant risks of morbidity and possibly mortality. Each patient should be counseled as to the risk of adverse effects as well as the likelihood of good results for alternative treatment strategies. This paper seeks to fill a gap in the existing medical literature, which has a paucity of data involving risk estimates for stereotactic radiosurgery

  20. Prompt-gamma neutron activation analysis system design. Effects of D-T versus D-D neutron generator source selection

    International Nuclear Information System (INIS)

    Shypailo, R.J.; Ellis, K.J.

    2008-01-01

    Prompt-gamma neutron activation (PGNA) analysis is used for the non-invasive measurement of human body composition. Advancements in portable, compact neutron generator design have made those devices attractive as neutron sources. Two distinct generators are available: D-D with 2.5 MeV and D-T with 14.2 MeV neutrons. To compare the performance of these two units in our present PGNA system, we performed Monte Carlo simulations (MCNP-5; Los Alamos National Laboratory) evaluating the nitrogen reactions produced in tissue-equivalent phantoms and the effects of background interference on the gamma-detectors. Monte Carlo response curves showed increased gamma production per unit dose when using the D-D generator, suggesting that it is the more suitable choice for smaller sized subjects. The increased penetration by higher energy neutrons produced by the D-T generator supports its utility when examining larger, especially obese, subjects. A clinical PGNA analysis design incorporating both neutron generator options may be the best choice for a system required to measure a wide range of subject phenotypes. (author)