  1. A Prototype for Passive Gamma Emission Tomography

    International Nuclear Information System (INIS)

    Honkamaa, T.; Levai, F.; Berndt, R.; Schwalbach, P.; Vaccaro, S.; ); Turunen, A.

    2015-01-01

    Combined efforts of multiple stakeholders of the IAEA Support Programme task JNT 1510: ''Prototype of passive gamma emission tomograph (PGET)'', resulted in the design, manufacturing and extensive testing of an advanced verification tool for partial defect testing on light water reactor spent fuel. The PGET has now reached a proven capability of detecting a single missing or substituted pin inside a BWR and VVER-440 fuel assemblies. The task started in 2004 and it is planned to be finished this year. The PGET head consists of two banks of 104 CdTe detectors each with integrated data acquisition electronics. The CdTe detectors are embedded in tungsten collimators which can be rotated around the fuel element using an integrated stepping motor mounted on a rotating table. All components are packed inside a toroid watertight enclosure. Control, data acquisition and image reconstruction analysis is fully computerized and automated. The design of the system is transportable and suitable for safeguards verifications in spent fuel ponds anywhere. Four test campaigns have been conducted. In 2009, the first test in Ringhals NPP failed collecting data but demonstrated suitability of the PGET for field deployments. Subsequent tests on fuel with increasing complexity were all successful (Ispra, Italy (2012), Olkiluoto, Finland (2013) and Loviisa, Finland (2014)). The paper will present the PGET design, results obtained from the test campaigns and mention also drawbacks that were experienced in the project. The paper also describes further tests which would allow evaluating the capabilities and limitations of the method and the algorithm used. Currently, the main technical shortcoming is long acquisition time, due to serial control and readout of detectors. With redesigned electronics it can be expected that the system would be able to verify a VVER-440 assembly in five minutes, which meets the IAEA user requirements. (author)

  2. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  3. Realization of a gamma emission tomography by a servo-controlled camera and bed

    International Nuclear Information System (INIS)

    Parmentier, M.; Gunzman, D.; Bidet, R.

    1979-01-01

    A gamma-camera and a whole-body bed were connected to a minicomputer which controlled automatically their movements. By combining horizontal displacement of the bed with vertical displacement and rotation of the camera we were able to obtain the equivalent of camera rotation around the bed. This method provides an inexpensive way of realizing gamma emission tomography [fr

  4. Positron emission tomography with gamma camera in coincidence mode

    International Nuclear Information System (INIS)

    Hertel, A.; Hoer, G.

    1999-01-01

    Positron emission tomography using F-18 FDG has been estbalished in clinical diagnostics with first indications especially in oncology. To install a conventional PET tomography (dedicated PET) is financially costly and restricted to PET examinations only. Increasing demand for PET diagnostics on one hand and restricted financial resources in the health system on the other hand led industry to develop SPECT cameras to be operated in coincidence mode (camera PET) in order to offer nuclear medicine physicians cost-effective devices for PET diagnostic. At the same time camera PET is inferior to conventional PET regarding sensitivity and detection-efficiency for 511 keV photons. Does camera-PET offer a reliable alternative to conventional PET? The first larger comparative studies are now available, so a first apraisal about the technical clinical performance of camera-PET can be done. (orig.) [de

  5. Characteristics of a single photon emission tomography system with a wide field gamma camera

    International Nuclear Information System (INIS)

    Mathonnat, F.; Soussaline, F.; Todd-Pokropek, A.E.; Kellershohn, C.

    1979-01-01

    This text summarizes a work study describing the imagery possibilities of a single photon emission tomography system composed of a conventional wide field gamma camera, connected to a computer. The encouraging results achieved on the various phantoms studied suggest a significant development of this technique in clinical work in Nuclear Medicine Departments [fr

  6. Single photon emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-09-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) imaging technique. Content: 1 - Introduction: anatomic, functional and molecular imaging; Principle and role of functional or molecular imaging; 2 - Radiotracers: chemical and physical constraints, main emitters, radioisotopes production, emitters type and imaging techniques; 3 - Single photon emission computed tomography: gamma cameras and their components, gamma camera specifications, planar single photon imaging characteristics, gamma camera and tomography; 4 - Quantification in single photon emission tomography: attenuation, scattering, un-stationary spatial resolution, partial volume effect, movements, others; 5 - Synthesis and conclusion

  7. A new gamma camera for positron emission tomography

    International Nuclear Information System (INIS)

    Schotanus, P.

    1988-01-01

    This thesis describes the detection of annihiliation radiation employing a new principle: radiation is absorbed in a barium fluoride (BaF 2) crystal and the resulting scintillation light is detected in a multiwire proportional chamber filled with a photsensitive vapour. The application of such a detector for PET is new; the use of a high density fast scintillator in combination with a low pressure wire chamber offers a good detection efficiency and permits high count rates because of the small dead time. In this work, the physical background of the above detection mechanism is explored and the performance parameters of a gamma camera using this new principle, are determined. Furthermore, a comprehensive research on the scintillation mechanism and physical characteristics of the increasingly popular BaF 2 scintillator is presented. Also, a new class of ultraviolet (UV) scintillation materials, consisting of rare earth doped fluorides, is introduced. (author). 211 refs.; 30 figs.; 17 tabs

  8. Voluminal modelling for the characterization of wastes packages by gamma emission computed tomography

    International Nuclear Information System (INIS)

    Pettier, J.L.; Thierry, R.

    2001-01-01

    The aim of this work is to model the measurement process used for multi-photon emission computed tomography on nuclear waste drum. Our model MEPHISTO (Multi-Energy PHoton Imagery through Segmented TOmography) takes into account all phenomena influencing gamma emergent flux and high resolution spectrometric measurements using an HpGe detector through a collimator aperture. These phenomena are absorption and Compton scattering of gamma photons in waste drum, geometrical blur, spatial and energetic response of the detector. The analysis of results shows better localisation and quantification performances compared with a Ray-Driven method. It proves the importance of an accurate modelization of collimated measurements to reduce noise and stabilize iterative image reconstructions. (authors)

  9. A model problem for restricted-data gamma ray emission tomography of highly active nuclear waste

    International Nuclear Information System (INIS)

    Cattle, Brian A.

    2007-01-01

    This paper develops the work of Cattle et al. [Cattle, B.A., Fellerman, A.S., West, R.M., 2004. On the detection of solid deposits using gamma ray emission tomography with limited data. Measurement Science and Technology 15, 1429-1439] by considering a generalization of the model employed therein. The focus of the work is the gamma ray tomographic analysis of high-level waste processing. The work in this paper considers a two-dimensional model for the measurement of gamma ray photon flux, as opposed to the previous one-dimensional analysis via the integrated Beer-Lambert law. The mathematical inverse problem that arises in determining physical quantities from the photon count measurements is tackled using Bayesian statistical methods that are implemented computationally using a Markov chain Monte Carlo (MCMC) approach. In a further new development, the effect of the degree of collimation of the detector on the reliability of the solutions is also considered

  10. Emission computerized axial tomography from multiple gamma-camera views using frequency filtering.

    Science.gov (United States)

    Pelletier, J L; Milan, C; Touzery, C; Coitoux, P; Gailliard, P; Budinger, T F

    1980-01-01

    Emission computerized axial tomography is achievable in any nuclear medicine department from multiple gamma camera views. Data are collected by rotating the patient in front of the camera. A simple fast algorithm is implemented, known as the convolution technique: first the projection data are Fourier transformed and then an original filter designed for optimizing resolution and noise suppression is applied; finally the inverse transform of the latter operation is back-projected. This program, which can also take into account the attenuation for single photon events, was executed with good results on phantoms and patients. We think that it can be easily implemented for specific diagnostic problems.

  11. Contribution to regularizing iterative method development for attenuation correction in gamma emission tomography

    International Nuclear Information System (INIS)

    Cao, A.

    1981-07-01

    This study is concerned with the transverse axial gamma emission tomography. The problem of self-attenuation of radiations in biologic tissues is raised. The regularizing iterative method is developed, as a reconstruction method of 3 dimensional images. The different steps from acquisition to results, necessary to its application, are described. Organigrams relative to each step are explained. Comparison notion between two reconstruction methods is introduced. Some methods used for the comparison or to bring about the characteristics of a reconstruction technique are defined. The studies realized to test the regularizing iterative method are presented and results are analyzed [fr

  12. Emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Gullberg, G.T.; Huesman, R.H.

    1979-01-01

    This chapter is devoted to the methods of computer assisted tomography for determination of the three-dimensional distribution of gamma-emitting radionuclides in the human body. The major applications of emission computed tomography are in biological research and medical diagnostic procedures. The objectives of these procedures are to make quantitative measurements of in vivo biochemical and hemodynamic functions

  13. Multiaxial tomography of heart chambers by gated blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Tamaki, N.; Mukai, T.; Ishii, Y.; Yonekura, Y.; Yamamoto, K.; Kadota, K.; Kambara, H.; Kawai, C.; Torizuka, K.

    1983-01-01

    Fifteen patients and three volunteers underwent radionuclide blood-pool cardiac studies with electrocardiographic gating. Following conventional planar-gated imaging (anterior and left anterior oblique projections), emission computed tomography (ECT), using a rotating gamma camera, was performed.A series of transaxial tomograms of the cardiac chambers was obtained. The left ventricular short-axis plane, long-axis plane, and four-chamber-view plane were then reorganized; each chamber was visualized separately. Compared to gated planar imaging, this technique showed regional asynergy more clearly in patients with myocardial infarction and demonstrated dilatation of the atria and ventricles more accurately in patients with an atrial septal defect and valvular heart diseases. In addition, when a section of the heart is otained at any angle with gated blood pool ECT, three-dimensional assessment of cardiac chambers in motion is more precise; mutual superimposition becomes unnecessary

  14. Gamma knife treatment for refractory epilepsy in seizure focus localized by positron emission tomography/CT★

    Science.gov (United States)

    Bai, Xia; Wang, Xuemei; Wang, Hongwei; Zhao, Shigang; Han, Xiaodong; Hao, Linjun; Wang, Xiangcheng

    2012-01-01

    A total of 80 patients with refractory epilepsy were recruited from the Inner Mongolia Medical College Affiliated Hospital. The foci of 60% of the patients could be positioned using a combined positron emission tomography/CT imaging modality. Hyper- and hypometabolism foci were examined as part of this study. Patients who had abnormal metabolism in positron emission tomography/CT imaging were divided into intermittent-phase group and the seizure-phase group. The intermittent-phase group was further divided into a single-focus group and a multiple-foci group according to the number of seizure foci detected by imaging. Following gamma knife treatment, seizure frequency was significantly lower in the intermittent-phase group and the seizure-phase group. Wieser’s classification reached Grade I or II in nearly 40% of patients. Seizure frequency was significantly lower following treatment, but Wieser’s classification score was significantly higher in the seizure-phase group compared with the intermittent-phase group. Seizure frequency was significantly lower following treatment in the single-focus group, but Wieser’s classification score was significantly higher in the single-focus group as compared with the multiple-foci group. PMID:25317147

  15. Gamma-Ray Emission Tomography: Modeling and Evaluation of Partial-Defect Testing Capabilities

    International Nuclear Information System (INIS)

    Jacobsson Svard, S.; Jansson, P.; Davour, A.; Grape, S.; White, T.A.; Smith, L.E.; Deshmukh, N.; Wittman, R.S.; Mozin, V.; Trellue, H.

    2015-01-01

    Gamma emission tomography (GET) for spent nuclear fuel verification is the subject for IAEA MSP project JNT1955. In line with IAEA Safeguards R&D plan 2012-2023, the aim of this effort is to ''develop more sensitive and less intrusive alternatives to existing NDA instruments to perform partial defect test on spent fuel assembly prior to transfer to difficult to access storage''. The current viability study constitutes the first phase of three, with evaluation and decision points between each phase. Two verification objectives have been identified; (1) counting of fuel pins in tomographic images without any a priori knowledge of the fuel assembly under study, and (2) quantitative measurements of pinby- pin properties, e.g., burnup, for the detection of anomalies and/or verification of operator-declared data. Previous measurements performed in Sweden and Finland have proven GET highly promising for detecting removed or substituted fuel rods in BWR and VVER-440 fuel assemblies even down to the individual fuel rod level. The current project adds to previous experiences by pursuing a quantitative assessment of the capabilities of GET for partial defect detection, across a broad range of potential IAEA applications, fuel types and fuel parameters. A modelling and performance-evaluation framework has been developed to provide quantitative GET performance predictions, incorporating burn-up and cooling-time calculations, Monte Carlo radiation-transport and detector-response modelling, GET instrument definitions (existing and notional) and tomographic reconstruction algorithms, which use recorded gamma-ray intensities to produce images of the fuel's internal source distribution or conclusive rod-by-rod data. The framework also comprises image-processing algorithms and performance metrics that recognize the inherent tradeoff between the probability of detecting missing pins and the false-alarm rate. Here, the modelling and analysis framework is

  16. Gamma camera based Positron Emission Tomography: a study of the viability on quantification

    International Nuclear Information System (INIS)

    Pozzo, Lorena

    2005-01-01

    Positron Emission Tomography (PET) is a Nuclear Medicine imaging modality for diagnostic purposes. Pharmaceuticals labeled with positron emitters are used and images which represent the in vivo biochemical process within tissues can be obtained. The positron/electron annihilation photons are detected in coincidence and this information is used for object reconstruction. Presently, there are two types of systems available for this imaging modality: the dedicated systems and those based on gamma camera technology. In this work, we utilized PET/SPECT systems, which also allows for the traditional Nuclear Medicine studies based on single photon emitters. There are inherent difficulties which affect quantification of activity and other indices. They are related to the Poisson nature of radioactivity, to radiation interactions with patient body and detector, noise due to statistical nature of these interactions and to all the detection processes, as well as the patient acquisition protocols. Corrections are described in the literature and not all of them are implemented by the manufacturers: scatter, attenuation, random, decay, dead time, spatial resolution, and others related to the properties of each equipment. The goal of this work was to assess these methods adopted by two manufacturers, as well as the influence of some technical characteristics of PET/SPECT systems on the estimation of SUV. Data from a set of phantoms were collected in 3D mode by one camera and 2D, by the other. We concluded that quantification is viable in PET/SPECT systems, including the estimation of SUVs. This is only possible if, apart from the above mentioned corrections, the camera is well tuned and coefficients for sensitivity normalization and partial volume corrections are applied. We also verified that the shapes of the sources used for obtaining these factors play a role on the final results and should be delt with carefully in clinical quantification. Finally, the choice of the region

  17. Evaluation of pulmonary nodules and lung cancer with one-inch crystal gamma coincidence positron emission tomography/CT versus dedicated positron emission tomography/CT

    International Nuclear Information System (INIS)

    Moodie, K.; Lau, E.; Hicks, R. J.; Cherk, M. H.; Turlakow, A.; Skinner, S.; Kelly, M. J.; Kalff, V.

    2009-01-01

    Full text: Dedicated positron emission tomography (PET)/CT scanners using BGO and related detectors (d-PET) have become standard imaging instruments in many malignancies. Hybrid gamma camera systems using Nal detectors in coincidence mode (g-PET) have been compared to d-PET but reported usefulness has been variable when gamma cameras with half-inch to three-fourth-inch thick crystals have been used without CT. Our aim was to compare g-PET with a 1-in.-thick crystal and inbuilt CT for lesion localization and attenuation correction (g-PET/CT) and d-PET/CT in patients presenting with potential and confirmed lung malignancies. One hour after 18F-fluorodeoxyglucose (FDG), patients underwent BGO d-PET/CT from jaw to proximal thigh. This was followed by one to two bed position g-PET/CT 194 + 27 min after FDG. Each study pair was independently analysed with concurrent CT. d-PET/CT was interpreted by a radiologist experienced in both PET and CT, and g-PET/CT by consensus reading of an experienced PET physician and an experienced CT radiologist, A TNM score was assigned and studies were then unblinded and compared. Fifty-seven patients underwent 58 scan pairs over 2 years. Eighty-nine percent concordance was shown between g-PET/CT and d-PET/CT for the assessment of I intrapulmonary lesions, with 100% concordance for intrapulmonary lesions I >10 mm (36 of 36). Eighty-eight per cent (51 of 58) concordance was shown between g-PET/CTand d-PET/CTforTNM staging. Coincidence imaging usingan optimized dual-head 1-in.-thick crystal gamma camera with inbuilt CT compares reasonably well with dedicated PET/CT for evaluation of indeterminate pulmonary lesions and staging of pulmonary malignancies and may be of some] value when d-PET/CT is not readily available.

  18. Emission computed tomography

    International Nuclear Information System (INIS)

    Ott, R.J.

    1986-01-01

    Emission Computed Tomography is a technique used for producing single or multiple cross-sectional images of the distribution of radionuclide labelled agents in vivo. The techniques of Single Photon Emission Computed Tomography (SPECT) and Positron Emission Tomography (PET) are described with particular regard to the function of the detectors used to produce images and the computer techniques used to build up images. (UK)

  19. An introduction to emission computed tomography

    International Nuclear Information System (INIS)

    Williams, E.D.

    1985-01-01

    This report includes salient features of the theory and an examination of practical considerations for someone who is using or introducing tomography, selecting equipment for it or wishing to develop a clinical application. Emphasis is on gamma camera tomography. The subject is dealt with under the following headings: emission computed and gamma camera tomography and the relationship to other medical imaging techniques, the tomographic reconstruction technique theory, rotating gamma camera tomography, attenuation correction and quantitative reconstruction, other single photon tomographic techniques, positron tomography, image display, clinical application of single photon and positron tomography, and commercial systems for SPECT. Substantial bibliography. (U.K.)

  20. Positron emission tomography

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.

    1985-01-01

    This book contains 24 selections. Some of the titles are: Positron Emission Tomography Instrumentation, Generator Systems for Positron Emitters, Reconstruction Algorithms, Cerebral Glucose Consumption: Methodology and Validation, Cerebral Blood Flow Tomography Using Xenon-133 Inhalation: Methods and Clinical Applications, PET Studies of Stroke, Cardiac Positron Emission Tomography, and Use of PET in Oncology

  1. Emission computed tomography using rotating gamma cameras for stress 201Tl myocardial imaging

    International Nuclear Information System (INIS)

    Takeda, Kan; Maeda, Hisato; Nakagawa, Tsuyoshi; Yamaguchi, Nobuo; Taguchi, Mitsuo

    1983-01-01

    The purpose of this study is to evaluate the efficacy of emission computed tomography (ECT) for stress 201 Tl myocardial imaging to localize coronary artery disease (CAD) in comparison with planar (PL) images. In a series of 14 normal subjects and 53 patients with CAD proved coronary arteriography, ECT and PL imaging were performed successively. ECT data were collected for 90 projections in a 64 x 64 matrix form with a total aquisition time of 6 munutes over 180 0 of opposed dual cameras ratation and tomographic sections oriented perpendicular and parallel to the long axis of left ventricle were reconstructed. PL images were obtained for left lateral, left anterior oblique (30 0 and 45 0 ) and anterior projections. Both ECT and PL myocardial images were divided into 8 segments and segmental analysis was performed by visual interpretation. The ECT images remarkably increased sensitivity over the PL images in left anterior descending (LAD) artery (from 56% to 76%), right coronary artery (RCA) (from 50% to 96%), and circumflex artery (CX) (from 56% to 69%) lesions. The specificity for ECT images, as compared with PL images, was higher in LAD (88% against 85%) but slightly lower in RCA (70% ag ainst 72%) and CX (84% against 88%). Overall accuracy, therefore, was improved in LAD (from 67% to 81%) and RCA (from 64% to 79%) but equal in CX (81%). We conclude that stress 201 Tl ECT imaging result in a remarkable improvement in the localization of CAD, especially in patients with RCA lesions and multi-vessel disease. (author)

  2. Regional cerebral blood flow measurement using N-isopropyl-p-[123I] iodoamphetamine and rotating gamma camera emission computed tomography

    International Nuclear Information System (INIS)

    Matsuda, Hiroshi; Seki, Hiroyasu; Ishida, Hiroko

    1985-01-01

    Thirty-one regional cerebral blood flow (rCBF) measurements were performed on 26 patients with cerebrovascular accidents using N-Isopropyl-p-[ 123 I] Iodoamphetamine ( 123 I-IMP) and rotating gamma camera emission computed tomography (ECT). The equation for determining rCBF is as follows: F=100.R.Cb/(N.A), where F is rCBF in ml/100 g/min., R is the constant withdrawal rate of arterial blood in ml/min., Cb is the brain activity concentration in μCi/g, A is the total activity (5 min.) in the withdrawal arterial whole blood in μCi and N is the fraction of A that is true tracer activity (0.75). In determining Cb at 5 min. after injection, reconstructed counts from 35 min. to 59 min. were corrected to represent those from 4 min. to 5 min. with the use of time activity curve for the entire brain immediately after injection to 30 min. Reconstructed counts of central region in tomographic image were corrected 118% of the obtained values from the result of the countingrate ratio between peripheral and central regions of interests obtained from phantom study. Brain mean blood flow values were distributed from 11 to 39 ml/100 g/min. In 119 cortical regions obtained from 11 measurements in 9 patients, there was a significant correlation (r=0.41, p 123 I-IMP and rotating gamma camera ECT and those from 133 Xe inhalation method. rCBF measurement using 123 I-IMP and rotating gamma camera ECT is not only relatively noninvasive measurement for the entire brain but also three-dimensional evaluation. Besides, it is superior in spatial resolution and accuracy to conventional 133 Xe clearance method. (author)

  3. Positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lindback, Stig [GEMS PET Systems AB, Uppsala (Sweden)

    1995-07-15

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body.

  4. Positron emission tomography

    International Nuclear Information System (INIS)

    Lindback, Stig

    1995-01-01

    Positron Emission Tomography (PET) is an advanced nuclear medicine technique used for research at major centres. Unique diagnostic information is obtained from tomographic measurements of the biochemistry and physiology of tissues and organs. In theory, diseases are related to biochemical changes and these can be observed with PET long before any anatomical changes are detectable. In PET the radioactive component is a positron-emitting isotope or 'tracer'. The positrons annihilate with electrons in the body to produce two gamma rays 180° apart; coincidence detection of these gammas provides a very efficient method of determining the spatial distribution of the radioisotope tracer. Because physiological measurements are usually required in a single imaging session, very short-lived isotopes are used to label the tracer molecules; isotope production and labelling is usually carried out in situ. The most commonly used radionuclides are carbon- 11 (half-life 20 minutes), nitrogen-13 (10 minutes), oxygen-15 (2 minutes), and fluorine-18 (110 minutes). A PET system has three major components: - a particle accelerator with targets for production of the positron-emitting isotopes; - chemistry modules for synthesis and labelling of the desired tracers; - and a PET camera for in-vivo measurements of the distribution of the tracer in the body

  5. Investigation of the Feasibility of Utilizing Gamma Emission Computed Tomography in Evaluating Fission Product Migration in Irradiated TRISO Fuel Experiments

    International Nuclear Information System (INIS)

    Harp, Jason M.; Demkowicz, Paul A.

    2014-01-01

    In the High Temperature Gas-Cooled Reactor (HTGR) the TRISO particle fuel serves as the primary fission product containment. However the large number of TRISO particles present in proposed HTGRs dictates that there will be a small fraction (~10"-"4 to 10"-"5) of as manufactured defects and in-pile particle failures that will lead to some fission product release. The matrix material surrounding the TRISO particles in fuel compacts and the structural graphite holding the TRISO particles in place can also serve as sinks for containing any released fission products. However data on the migration of solid fission products through these materials is lacking. One of the primary goals of the AGR-3/4 experiment is to study fission product migration from intentionally failed TRISO particles in prototypic HTGR components such as structural graphite and compact matrix material. In this work, the potential for a Gamma Emission Computed Tomography (GECT) technique to non-destructively examine the fission product distribution in AGR-3/4 components and other irradiation experiments is explored. Specifically, the feasibility of using the Idaho National Laboratory (INL) Hot Fuels Examination Facility (HFEF) Precision Gamma Scanner (PGS) system for this GECT application was considered. Previous experience utilizing similar techniques, the expected activities in AGR-3/4 rings, and analysis of this work indicate using GECT to evaluate AGR-3/4 will be feasible. The GECT technique was also applied to other irradiated nuclear fuel systems currently available in the HFEF hot cell, including oxide fuel pins, metallic fuel pins, and monolithic plate fuel. Results indicate GECT with the HFEF PGS is effective. (author)

  6. High-precision gamma-ray spectroscopy of 61Cu, an emerging medical isotope used in positron emission tomography

    Science.gov (United States)

    Nelson, N.; Ellison, P.; Nickles, R.; McCutchan, E.; Sonzogni, A.; Smith, S.; Greene, J.; Carpenter, M.; Zhu, S.; Lister, C.; Moran, K.

    2017-09-01

    61Cu (t1 / 2 = 3.339h) is an important medical isotope used in positron emission tomography (PET) tumor hypoxia imaging scans; however, its beta-plus decay and the subsequent gamma decay of 61Ni has not been studied in over 30 years. Therefore, high quality decay data of 61Cu is desired to determine the overall dose delivered to a patient. In this study, 61Cu was produced at the University of Wisconsin - Madison cyclotron and then assayed using the Gammasphere array at Argonne National Laboratory. Consisting of 70 Compton-suppressed high-purity germanium (HPGe) detectors, Gammasphere provides precise decay data that exceeds that of previous 61Cu studies. γ-ray singles and coincident data were recorded and then analyzed using Radware gf3m software. Through γ- γ coincidence techniques, new γ-ray transitions were identified and high precision determination of γ-ray intensities were made. These modifications and additions to the current decay scheme will be presented, and their impact on the resulting does estimates will be discussed. DOE Isotope Program is acknowledged for funding ST5001030. Work supported by the U.S. DOE under Grant No. DE-FG02-94ER40848 and Contract Nos. DE-AC02-98CH10946 and DE-AC02-06CH11357 and by the Science Undergraduate Laboratory Internship Program (SULI).

  7. Positron emission tomography. Basic principles

    International Nuclear Information System (INIS)

    Rodriguez, Jose Luis; Massardo, Teresa; Gonzalez, Patricio

    2001-01-01

    The basic principles of positron emission tomography (PET) technique are reviewed. lt allows to obtain functional images from gamma rays produced by annihilation of a positron, a positive beta particle. This paper analyzes positron emitters production in a cyclotron, its general mechanisms, and the various detection systems. The most important clinical applications are also mentioned, related to oncological uses of fluor-l8-deoxyglucose

  8. In-vivo Diagnosis of Breast Cancer Using Gamma Stimulated Emission Computed Tomography

    Science.gov (United States)

    2011-04-01

    DUKE UNIVERSITY. Downloaded on May 07,2010 at 21:39:16 UTC from IEEE Xplore . Restrictions apply. Fig.4. shows the number of gamma-rays detected...2421 Authorized licensed use limited to: DUKE UNIVERSITY. Downloaded on May 07,2010 at 21:39:16 UTC from IEEE Xplore . Restrictions apply...21:39:16 UTC from IEEE Xplore . Restrictions apply. Quantitative Elemental Imaging with Neutrons for Breast Cancer Diagnosis: a GEANT4 Study

  9. Quantification in emission tomography

    International Nuclear Information System (INIS)

    Buvat, Irene

    2011-11-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) and positron emission tomography (PET) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena 2 - Main problems impacting quantification in PET and SPECT: problems, consequences, correction methods, results (Attenuation, scattering, partial volume effect, movement, un-stationary spatial resolution in SPECT, fortuitous coincidences in PET, standardisation in PET); 3 - Synthesis: accessible efficiency, know-how, Precautions, beyond the activity measurement

  10. Single photon emission computed tomography of the brain with a rotating gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Biersack, H J; Knopp, R; Winkler, C; Wappenschmidt, J

    1981-08-01

    In 471 patients SPECT of the brain was performed in addition to conventional serial brain scintigraphy using a rotating gamma camera (GAMMATOME T 9000). 23 patients had tumorous lesions, 26 had vascular lesions, and 422 patients revealed normal brain findings. 5 of the 23 patients with tumorous lesion and 5 of the 12 patients with vascular lesion (anamnesis shorter than 4 weeks) showed positive SPECT results but false negative conventional brain scans. Specificity could be improved up to 98% (412 out of 422 patients) using SPECT and conventional scintigraphy.

  11. Cardiac positron emission tomography

    International Nuclear Information System (INIS)

    Eftekhari, M.; Ejmalian, G.

    2003-01-01

    Positron emission tomography is an intrinsically tool that provide a unique and unparalleled approach for clinicians and researchers to interrogate the heart noninvasively. The ability to label substances of physiological interest with positron-emitting radioisotopes has permitted insight into normal blood flow and metabolism and the alterations that occur with disease states. Positron emission tomography of the heart has evolved as a unique, noninvasive approach for the assessment of myocardial perfusion, metabolism, and function. Because of the intrinsic quantitative nature of positron emission tomography measurements as well as the diverse compounds that can be labeled with positron- emitting radioisotopes, studies with positron emission tomography have provided rich insight into the physiology of the heart under diverse conditions

  12. Positron emission tomography

    International Nuclear Information System (INIS)

    Iio, Masahiro

    1982-01-01

    Utilization of positron emission tomography was reviewed in relation to construction and planned construction of small-size medical cyclotrons, planned construction of positron cameras and utilization of short-lived radionuclides. (Chiba, N.)

  13. Positron emission tomography

    International Nuclear Information System (INIS)

    Dvorak, O.

    1989-01-01

    The principle is briefly described of positron emission tomography, and its benefits and constraints are listed. It is emphasized that positron emission tomography (PET) provides valuable information on metabolic changes in the organism that are otherwise only very difficult to obtain, such as brain diagnosis including relationships between mental disorders and the physiology and pathophysiology of the brain. A PET machine is to be installed in Czechoslovakia in the near future. (L.O.)

  14. Positron emission tomography

    International Nuclear Information System (INIS)

    Wienhard, K.; Heiss, W.D.

    1984-01-01

    The principles and selected clinical applications of positron emission tomography are described. In this technique a chemical compound is labeled with a positron emitting isotope and its biochemical pathway is traced by coincidence detection of the two annihilation photons. The application of the techniques of computed tomography allows to reconstruct the spatial distribution of the radioactivity within a subject. The 18 F-deoxyglucose method for quantitative measurement of local glucose metabolism is discussed in order to illustrate the possibilities of positron emission tomography to record physiological processes in vivo. (orig.) [de

  15. The review of myocardial positron emission computed tomography and positron imaging by gamma camera

    Energy Technology Data Exchange (ETDEWEB)

    Ohtake, Tohru [Tokyo Univ. (Japan). Faculty of Medicine

    1998-04-01

    To measure myocardial blood flow, Nitrogen-13 ammonia, Oxygen-15 water, Rubidium-82 and et al. are used. Each has merit and demerit. By measuring myocardial coronary flow reserve, the decrease of flow reserve during dipyridamole in patients with hypercholesterolemia or diabetes mellitus without significant coronary stenosis was observed. The possibility of early detection of atherosclerosis was showed. As to myocardial metabolism, glucose metabolism is measured by Fluorine-18 fluorodeoxyglucose (FDG), and it is considered as useful for the evaluation of myocardial viability. We are using FDG to evaluate insulin resistance during insulin clamp in patients with diabetes mellitus by measuring glucose utilization rate of myocardium and skeletal muscle. FFA metabolism has been measured by {sup 11}C-palmitate, but absolute quantification has not been performed. Recently the method for absolute quantification was reported, and new radiopharmaceutical {sup 18}F-FTHA was reported. Oxygen metabolism has been estimated by {sup 11}C-acetate. Myocardial viability, cardiac efficiency was evaluated by oxygen metabolism. As to receptor or sympathetic nerve end, cardiac insufficiency or cardiac transplantation was evaluated. Imaging of positron emitting radiopharmaceutical by gamma camera has been performed. Collimator method is clinically useful for cardiac imaging of viability study. (author). 54 refs.

  16. Outcomes of the JNT 1955 Phase I Viability Study of Gamma Emission Tomography for Spent Fuel Verification

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsson-Svard, Staffan; Smith, Leon E.; White, Timothy; Mozin, Vladimir V.; Jansson, Peter; Davour, Anna; Grape, Sophie; Trellue, Holly R.; Deshmukh, Nikhil S.; Wittman, Richard S.; Honkamaa, Tapani; Vaccaro, Stefano; Ely, James

    2017-05-17

    The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly has been assessed within the IAEA Support Program project JNT 1955, phase I, which was completed and reported to the IAEA in October 2016. Two safeguards verification objectives were identified in the project; (1) independent determination of the number of active pins that are present in a measured assembly, in the absence of a priori information about the assembly; and (2) quantitative assessment of pin-by-pin properties, for example the activity of key isotopes or pin attributes such as cooling time and relative burnup, under the assumption that basic fuel parameters (e.g., assembly type and nominal fuel composition) are known. The efficacy of GET to meet these two verification objectives was evaluated across a range of fuel types, burnups and cooling times, while targeting a total interrogation time of less than 60 minutes. The evaluations were founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types were used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. The simulated instrument response data were then processed using a variety of tomographic-reconstruction and image-processing methods, and scoring metrics were defined and used to evaluate the performance of the methods.This paper describes the analysis framework and metrics used to predict tomographer performance. It also presents the design of a “universal” GET (UGET) instrument intended to support the full range of verification scenarios envisioned by the IAEA. Finally, it gives examples of the expected partial-defect detection capabilities for some fuels and diversion scenarios, and it provides a comparison of predicted performance for the notional UGET design and an optimized variant of an existing IAEA instrument.

  17. Positron emission tomography

    International Nuclear Information System (INIS)

    Chandrasekhar, Preethi; Himabindu, Pucha

    2000-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging technique used to study different molecular pathways and anatomical structures. PET has found extensive applications in various fields of medicine viz. cardiology, oncology, psychiatry/psychology, neuro science and pulmonology. This study paper basically deals with the physics, chemistry and biology behind the PET technique. It discusses the methodology for generation of the radiotracers responsible for emission of positrons and the annihilation and detection techniques. (author)

  18. Emission tomography for adrenal imaging

    International Nuclear Information System (INIS)

    Britton, K.E.; Shapiro, B.; Hawkins, L.A.

    1980-01-01

    Single photon emission tomography (SPET) of the adrenals was compared to convential gamma camera images. Depths of 19 adrenals were assessed by both the lateral skin-upper kidney pole method and by SPET. Eleven patients with adrenal disorders were also studied. An advantage of using SPET was that the analogue transverse section image showed improvement over the conventional posterior view because the liver activity was well separated from the adrenal. Furthermore, non-adrenal tissue background was virtually eliminated and adrenal depth determination facilitated. (U.K.)

  19. single photon emission tomography and positron emission tomography - Part 1 (October 2012), Part 2 (October 2010)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2010-10-01

    The objective of this lecture is to present the single photon emission computed tomography (SPECT) and the positron emission tomography (PET) imaging techniques. Part 1 Content: 1 - Introduction: anatomic, functional and molecular imaging; 2 - Radiotracers: chemical and physical constraints, gamma photon emitters, positon emitters, radioisotopes production, emitters type and imaging techniques; 3 - Gamma cameras; 4 - Quantification in emission tomography: attenuation, scattering, un-stationary spatial resolution; 5 - Synthesis and conclusion. Part 2 content: 1 - Positon emitters; 2 - Positons detection: Coincidence detection (electronic collimation, PET detectors with gamma cameras, dedicated PET detectors, spectrometry); PET detectors type; time-of-flight PET; 2D PET; 3D PET; 3 - Quantification in emission tomography: detected events, attenuation, scattering, fortuitous coincidences, standardisation; 4 - Common SPECT and PET problems: partial volume effect, movement, tomographic reconstruction, calibration, dead time; 5 - Synthesis and conclusion

  20. Positron emission tomography

    International Nuclear Information System (INIS)

    Pavuk, M.

    2003-12-01

    The aim of this project is to provide a simple summary of new trends in positron emission tomography and its basic physical principles. It provides thereby compendious introduction of the trends of the present development in diagnostics using PET systems. A review of available literature was performed. (author)

  1. Positron emission tomography

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation using a

  2. Single photon emission computerized tomography

    International Nuclear Information System (INIS)

    Hooge, P. de.

    1983-01-01

    In this thesis two single-photon emission tomographic techniques are presented: (a) longitudinal tomography with a rotating slanting-hole collimator, and (b) transversal tomography with a rotating gamma camera. These methods overcome the disadvantages of conventional scintigraphy. Both detection systems and the image construction methods are explained and comparisons with conventional scintigraphy are drawn. One chapter is dedicated to the determination of system parameters like spatial resolution, contrast, detector uniformity, and size of the object, by phantom studies. In separate chapters the results are presented of detection of tumors and metastases in the liver and the liver hilus; skeletal diseases; various pathological aberrations of the brain; and myocardial perfusion. The possible use of these two ect's for other organs and body areas is discussed in the last chapter. (Auth.)

  3. High-resolution emission tomography of small laboratory animals: physics and gamma-astronomy meet molecular biology

    International Nuclear Information System (INIS)

    Beekman, F.J.; Colijn, A.P.; Vastenhouw, B.; Wiegant, V.M.; Gerrits, M.A.F.M.

    2003-01-01

    Molecular imaging can be defined as the characterization and measurement of biological processes in living animals, model systems and humans at the cellular and molecular level using remote imaging detectors. An example concerns the mapping of the distributions of radioactively labeled molecules in laboratory animals which is of crucial importance for life sciences. Tomographic methods like Single Photon Emission Computed Tomography (SPECT) offer a possibility to visualize distributions of radioactively labeled molecules in living animals. Miniature tomography systems, derived from their clinical counterparts, but with a much higher image resolution are under development in several institutes. An example is U-SPECT that will be discussed in the present paper. Such systems are expected to accelerate several biomedical research procedures, the understanding of gene and protein function, as well as pharmaceutical development

  4. Positron emission tomography

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Diksic, M.; Meyer, E.; Feindel, W.H.

    1984-01-01

    One of the most exciting new technologies introduced in the last 10 yr is positron emission tomography (PET). PET provides quantitative, three-dimensional images for the study of specific biochemical and physiological processes in the human body. This approach is analogous to quantitative in-vivo autoradiography but has the added advantage of permitting non-invasive in vivo studies. PET scanning requires a small cyclotron to produce short-lived positron emitting isotopes such as oxygen-15, carbon-11, nitrogen-13 and fluorine-18. Proper radiochemical facilities and advanced computer equipment are also needed. Most important, PET requires a multidisciplinary scientific team of physicists, radiochemists, mathematicians, biochemists and physicians. The most recent trends are reviewed in the imaging technology, radiochemistry, methodology and clinical applications of positron emission tomography. (author)

  5. Positron emission tomography

    International Nuclear Information System (INIS)

    Marchenkov, N.S.

    2000-01-01

    The foundations of the positron emission tomography (PET), widely used for the medical diagnostics, are considered. The brief description of the cyclotron for production of radionuclides, applied in the PET, the target devices for manufacturing the position emitters, the moduli for the radiopharmaceuticals synthesis (RPS) for the PET is presented. The necessity and concept of complete automation of the RPS for the PET are discussed [ru

  6. Positron emission tomography

    International Nuclear Information System (INIS)

    Paans, A.M.J.

    1981-01-01

    Positron emitting radiopharmaceuticals have special applications in in-vivo studies of biochemical processes. The combination of a cyclotron for the production of radionuclides and a positron emission tomograph for the registration of the distribution of radioactivity in the body enables the measurement of local radioactivity concentration in tissues, and opens up new possibilities in the diagnosis and examination of abnormalities in the metabolism. The principles and procedures of positron emission tomography are described and the necessary apparatus considered, with emphasis on the positron camera. The first clinical applications using 55 Co bloemycine for tumor detection are presented. (C.F.)

  7. Development of small-diameter lead-glass-tube matrices for gamma-ray conversion in positron emission tomography

    International Nuclear Information System (INIS)

    Schwartz, G.M.

    1985-05-01

    A gamma-ray converter for a multiwire proportional chamber (MWPC) positron emission tomograph is described. The converter is made of small-diameter (0.48 mm inner diameter, 0.06 mm wall thickness) lead-oxide-glass tubes fused to form a honeycomb matrix. The surfaces of the tubes are reduced in a hydrogen atmosphere to provide the drift electric field for detection of the conversion electrons. The detection efficiency for a 10 mm thick converter is 6.65%, with a time resolution of 160 ns (FWHM). A scheme which will improve the spatial resolution of the tomograph by use of the self quenching streamer mode of chamber operation is described. Details of construction of the converters and the MWPC are presented, as well as the design performance of a high spatial resolution positron emission tomograph (HISPET). 40 refs., 22 figs

  8. Tomography by positrons emission

    International Nuclear Information System (INIS)

    Mosconi, Sergio L.

    1999-01-01

    The tomography by positrons emission is a technology that allows to measure the concentration of positrons emission in a tri dimensional body through external measurements. Among the isotope emissions have carbon isotopes are ( 11 C), of the oxygen ( 15 O), of the nitrogen ( 13 N) that are three the element that constitute the base of the organic chemistry. Theses have on of the PET's most important advantages, since many biological interesting organic molecules can be tracer with these isotopes for the metabolism studies 'in vivo' through PET, without using organic tracers that modify the metabolism. The mentioned isotopes, also possess the characteristic of having short lifetime, that constitute on of PET's advantages from the dosimetric point of view. Among 11 C, 15 O, and 13 N, other isotopes that can be obtained of a generator as the 68 Ga and 82 Rb

  9. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs

  10. Positron Emission Tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M.J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET. 22 figs.

  11. Positron Emission Tomography (PET)

    Science.gov (United States)

    Welch, M. J.

    1990-01-01

    Positron emission tomography (PET) assesses biochemical processes in the living subject, producing images of function rather than form. Using PET, physicians are able to obtain not the anatomical information provided by other medical imaging techniques, but pictures of physiological activity. In metaphoric terms, traditional imaging methods supply a map of the body's roadways, its, anatomy; PET shows the traffic along those paths, its biochemistry. This document discusses the principles of PET, the radiopharmaceuticals in PET, PET research, clinical applications of PET, the cost of PET, training of individuals for PET, the role of the United States Department of Energy in PET, and the futures of PET.

  12. Positron emission tomography

    CERN Document Server

    Paans, A M J

    2006-01-01

    Positron Emission Tomography (PET) is a method for measuring biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labelled with positron emitting radionuclides such as 11C, 13N, 15O and 18F and by measuring the annihilation radiation using a coincidence technique. This includes also the measurement of the pharmacokinetics of labelled drugs and the measurement of the effects of drugs on metabolism. Also deviations of normal metabolism can be measured and insight into biological processes responsible for diseases can be obtained. At present the combined PET/CT scanner is the most frequently used scanner for whole-body scanning in the field of oncology.

  13. Positron emission tomography. Positronemisionstomografi

    Energy Technology Data Exchange (ETDEWEB)

    Bolwig, T G; Haunsoe, S; Dahlgaard Hove, J; Hesse, B; Hoejgard, L; Jensen, M; Paulson, O B; Hastrup Svendsen, J; Soelvsten Soerensen, S

    1994-10-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ([sup 11]C), oxygen ([sup 15]O), and nitrogen ([sup 13]N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.).

  14. Positron emission tomography

    International Nuclear Information System (INIS)

    Bolwig, T.G.; Haunsoe, S.; Dahlgaard Hove, J.; Hesse, B.; Hoejgard, L.; Jensen, M.; Paulson, O.B.; Hastrup Svendsen, J.; Soelvsten Soerensen, S.

    1994-01-01

    Positron emission tomography (PET) is a method for quantitative imaging of regional physiological and biochemical parameters. Positron emitting radioactive isotopes can be produced by a cyclotron, eg. the biologically important carbon ( 11 C), oxygen ( 15 O), and nitrogen ( 13 N) elements. With the tomographic principles of the PET scanner the quantitative distribution of the administered isotopes can be determined and images can be provided as well as dynamic information on blood flow, metabolism and receptor function. In neurology PET has been used for investigations on numerous physiological processes in the brain: circulation, metabolism and receptor studies. In Parkinson's disease PET studies have been able to localize the pathology specifically, and in early stroke PET technique can outline focal areas with living but non-functioning cells, and this could make it possible to intervene in this early state. With positron emission tomography a quantitative evaluation of myocardial blood flow, glucose and fatty acid metabolism can be made as well as combined assessments of blood flow and metabolism. Combined studies of blood flow and metabolism can determine whether myocardial segments with abnormal motility consist of necrotic or viable tissue, thereby delineating effects of revascularisation. In the future it will probably be possible to characterize the myocardial receptor status in different cardiac diseases. The PET technique is used in oncology for clinical as well as more basic research on tumor perfusion and metabolism. Further, tumor uptake of positron labelled cytotoxic drugs might predict the clinical benefit of treatment. (au) (19 refs.)

  15. Emission computed tomography

    International Nuclear Information System (INIS)

    Phelps, M.E.

    1977-01-01

    Although there are many common aspects to x-ray transmission and radionuclide emission (ECT) computerized tomography, there are added difficulties and a number of particular factors which form the basis of ECT. The relationship between the physical factors, system design, methodologic approach and assumptions of ECT is discussed. The instrumentation design and application strategies in ECT at this time are diverse and in a rapid stage of development. The approaches are divided into two major categories of Single Photon Counting (SPC) employing scanner and camera concepts with radionuclides of 99 /sup m/Tc, 201 Tl, 123 I etc., and Annihilation Coincidence Detection (ACD) of positron-emitting radionuclides. Six systems in the former and ten systems in the latter category, with examples of typical studies, illustrate the different approaches

  16. Positron emission computed tomography

    International Nuclear Information System (INIS)

    Grover, M.; Schelbert, H.R.

    1985-01-01

    Regional mycardial blood flow and substrate metabolism can be non-invasively evaluated and quantified with positron emission computed tomography (Positron-CT). Tracers of exogenous glucose utilization and fatty acid metabolism are available and have been extensively tested. Specific tracer kinetic models have been developed or are being tested so that glucose and fatty acid metabolism can be measured quantitatively by Positron-CT. Tracers of amino acid and oxygen metabolism are utilized in Positron-CT studies of the brain and development of such tracers for cardiac studies are in progress. Methods to quantify regional myocardial blood flow are also being developed. Previous studies have demonstrated the ability of Positron-/CT to document myocardial infarction. Experimental and clinical studies have begun to identify metabolic markers of reversibly ischemic myocardium. The potential of Positron-CT to reliably detect potentially salvageable myocardium and, hence, to identify appropriate therapeutic interventions is one of the most exciting applications of the technique

  17. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector planes positioned side-by-side around a patient area to detect radiation. Each plane includes a plurality of photomultiplier tubes and at least two rows of scintillation crystals on each photomultiplier tube extend across to adjacent photomultiplier tubes for detecting radiation from the patient area. Each row of crystals on each photomultiplier tube is offset from the other rows of crystals, and the area of each crystal on each tube in each row is different than the area of the crystals on the tube in other rows for detecting which crystal is actuated and allowing the detector to detect more inter-plane slides. The crystals are offset by an amount equal to the length of the crystal divided by the number of rows. The rows of crystals on opposite sides of the patient may be rotated 90 degrees relative to each other

  18. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each ring contains a plurality of scintillation detectors which are positioned around an inner circumference with a septum ring extending inwardly from the inner circumference along each outer edge of each ring. An additional septum ring is positioned in the middle of each ring of detectors and parallel to the other septa rings, whereby the inward extent of all the septa rings may be reduced by one-half and the number of detectors required in each ring is reduced. The additional septa reduces the costs of the positron camera and improves its performance

  19. Positron emission tomography camera

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    A positron emission tomography camera having a plurality of detector rings positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom. Each detector ring or offset ring includes a plurality of photomultiplier tubes and a plurality of scintillation crystals are positioned relative to the photomultiplier tubes whereby each tube is responsive to more than one crystal. Each alternate crystal in the ring is offset by one-half or less of the thickness of the crystal such that the staggered crystals are seen by more than one photomultiplier tube. This sharing of crystals and photomultiplier tubes allows identification of the staggered crystal and the use of smaller detectors shared by larger photomultiplier tubes thereby requiring less photomultiplier tubes, creating more scanning slices, providing better data sampling, and reducing the cost of the camera. The offset detector ring geometry reduces the costs of the positron camera and improves its performance

  20. Regional cerebral blood flow measurement using N-isopropyl-p-(/sup 123/I) iodoamphetamine and rotating gamma camera emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Hiroshi; Seki, Hiroyasu; Ishida, Hiroko (Kanazawa Univ. (Japan). School of Medicine)

    1985-01-01

    Thirty-one regional cerebral blood flow (rCBF) measurements were performed on 26 patients with cerebrovascular accidents using N-Isopropyl-p-(/sup 123/I) Iodoamphetamine (/sup 123/I-IMP) and rotating gamma camera emission computed tomography (ECT). The equation for determining rCBF is as follows: F=100.R.Cb/(N.A), where F is rCBF in ml/100 g/min., R is the constant withdrawal rate of arterial blood in ml/min., Cb is the brain activity concentration in ..mu..Ci/g, A is the total activity (5 min.) in the withdrawal arterial whole blood in ..mu..Ci and N is the fraction of A that is true tracer activity (0.75). In determining Cb at 5 min. after injection, reconstructed counts from 35 min. to 59 min. were corrected to represent those from 4 min. to 5 min. with the use of time activity curve for the entire brain immediately after injection to 30 min. Reconstructed counts of central region in tomographic image were corrected 118% of the obtained values from the result of the counting rate ratio between peripheral and central regions of interest obtained from phantom study. Brain mean blood flow values were distributed from 11 to 39 ml/100 g/min. In 119 cortical regions obtained from 11 measurements in 9 patients, there was a significant correlation (r=0.41, p < 0.001) between rCBF values obtained from /sup 123/I-IMP and rotating gamma camera ECT and those from /sup 133/Xe inhalation method. rCBF measurement using /sup 123/I-IMP and rotating gamma camera ECT is not only relatively noninvasive measurement for the entire brain but also three-dimensional evaluation. Besides, it is superior in spatial resolution and accuracy to conventional /sup 133/Xe clearance method.

  1. [Diagnostic use of positron emission tomography in France: from the coincidence gamma-camera to mobile hybrid PET/CT devices].

    Science.gov (United States)

    Talbot, Jean-Noël

    2010-11-01

    Positron emission tomography (PET) is a well-established medical imaging method. PET is increasingly used for diagnostic purposes, especially in oncology. The most widely used radiopharmaceutical is FDG, a glucose analogue. Other radiopharmaceuticals have recently been registered or are in development. We outline technical improvements of PET machines during more than a decade of clinical use in France. Even though image quality has improved considerably and PET-CT hybrid machines have emerged, spending per examination has remained remarkably constant. Replacement and maintenance costs have remained in the range of 170-190 Euros per examination since 1997, whether early CDET gamma cameras or the latest time-of-flight PET/CT devices are used. This is mainly due to shorter acquisition times and more efficient use of FDG New reimbursement rates for PET/CT are needed in France in order to favor regular acquisition of state-of-the-art devices. One major development is the coupling of PET and MR imaging.

  2. Diagnosis of myocardial viability by dual-head coincidence gamma camera fluorine-18 fluorodeoxyglucose positron emission tomography with and without non-uniform attenuation correction

    International Nuclear Information System (INIS)

    Nowak, B.; Zimmy, M.; Kaiser, H.-J.; Schaefer, W.; Reinartz, P.; Buell, U.; Schwarz, E.R.; Dahl, J. vom

    2000-01-01

    This study assessed a dual-head coincidence gamma camera (hybrid PET) equipped with single-photon transmission for myocardial fluorine-18 fluorodeoxyglucose (FDG) imaging by comparing this technique with conventional positron emission tomography (PET) using a dedicated ring PET scanner. Twenty-one patients were studied with dedicated FDG ring PET and FDG hybrid PET for evaluation of myocardial glucose metabolism, as well as technetium-99 m tetrofosmin single-photon emission tomography (SPET) to estimate myocardial perfusion. All patients underwent transmitted attenuation correction using germanium-68 rod sources for ring PET and caesium-137 point sources for hybrid PET. Ring PET and hybrid PET emission scans were started 61±12 and 98±15 min, respectively, after administration of 154±31 MBq FDG. Attenuation-corrected images were reconstructed iteratively for ring PET and hybrid PET (ac-hybrid PET), and non-attenuation-corrected images for hybrid PET (non-ac-hybrid PET) only. Tracer distribution was analysed semiquantitatively using a volumetric vector sampling method dividing the left ventricular wall into 13 segments. FDG distribution in non-ac-hybrid PET and ring PET correlated with r=0.36 (P<0.0001), and in ac-hybrid PET and ring PET with r=0.79 (P<0.0001). Non-ac-hybrid PET significantly overestimated FDG uptake in the apical and supra-apical segments, and underestimated FDG uptake in the remaining segments, with the exception of one lateral segment. Ac-hybrid PET significantly overestimated FDG uptake in the apical segment, and underestimated FDG uptake in only three posteroseptal segments. A three-grade score was used to classify diagnosis of viability by FDG PET in 136 segments with reduced perfusion as assessed by SPET. Compared with ring PET, non-ac-hybrid PET showed concordant diagnoses in 80 segments (59%) and ac-hybrid PET in 101 segments (74%) (P<0.001). Agreement between ring PET and non-ac-hybrid PET was best in the basal lateral wall and in the

  3. Neutron stimulated emission computed tomography: Background corrections

    International Nuclear Information System (INIS)

    Floyd, Carey E.; Sharma, Amy C.; Bender, Janelle E.; Kapadia, Anuj J.; Xia, Jessie Q.; Harrawood, Brian P.; Tourassi, Georgia D.; Lo, Joseph Y.; Kiser, Matthew R.; Crowell, Alexander S.; Pedroni, Ronald S.; Macri, Robert A.; Tajima, Shigeyuki; Howell, Calvin R.

    2007-01-01

    Neutron stimulated emission computed tomography (NSECT) is an imaging technique that provides an in-vivo tomographic spectroscopic image of the distribution of elements in a body. To achieve this, a neutron beam illuminates the body. Nuclei in the body along the path of the beam are stimulated by inelastic scattering of the neutrons in the beam and emit characteristic gamma photons whose unique energy identifies the element. The emitted gammas are collected in a spectrometer and form a projection intensity for each spectral line at the projection orientation of the neutron beam. Rotating and translating either the body or the beam will allow a tomographic projection set to be acquired. Images are reconstructed to represent the spatial distribution of elements in the body. Critical to this process is the appropriate removal of background gamma events from the spectrum. Here we demonstrate the equivalence of two background correction techniques and discuss the appropriate application of each

  4. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment

  5. NMF on positron emission tomography

    DEFF Research Database (Denmark)

    Bödvarsson, Bjarni; Hansen, Lars Kai; Svarer, Claus

    2007-01-01

    In positron emission tomography, kinetic modelling of brain tracer uptake, metabolism or binding requires knowledge of the cerebral input function. Traditionally, this is achieved with arterial blood sampling in the arm or as shown in (Liptrot, M, et al., 2004) by non-invasive K-means clustering....... We propose another method to estimate time-activity curves (TAC) extracted directly from dynamic positron emission tomography (PET) scans by non-negative matrix factorization (NMF). Since the scaling of the basis curves is lost in the NMF the estimated TAC is scaled by a vector alpha which...

  6. Cerebral emission computer tomography with a rotating gamma camera: clinic results with J-123 Isopropylamphetamin and J-123-Fenetyllin

    International Nuclear Information System (INIS)

    Biersack, H.J.; Hartmann, A.; Froescher, W.; Reske, S.-N.; Reichmann, K.; Knopp, R.; Winkler, C.

    1984-01-01

    Many amines can pass the blood brain barrier and accumulate in relatively large amounts in the brain tissue. For about 2 years 123-J amphetamines have, therefore, been used for brain imaging by several teams. Our experience sofar is based on 28 patients. Of these, 14 were epileptics, 10 had cerebrovascular diseases, 2 suffered from migraine and another 2 had brain tumors. In 3 patients with vascular lesions studies were repeated twice or three times. Amphetamine uptake in the brain was measured with a rotating gamma camera system (Gammatome T9000/CGR). At an examination time of 20 minutes 64 frames were acquired during one full rotation. The pulse rate was about 3000 second after injecting 6.5 mCi of 123-J amphetamine. Of the epileptics, 8 showed defects both on CT and SPECT, in 3 cases both studies were normal. While 1 patient with CT positivity had a normal SPECT, 2 cases were found to have lesions on SPECT inspite of a normal CT. The size of the lesion seen on amphetamine SPECT was lager than on CT in 3 of 9 patients. In the 10 patients with cerebrovascular lesions the 2 procedures showed concordant normal patterns in 1 and concordant abnormal patterns in 7 instances. 2 patients with normal CT were found to have a lesion on amphetamine scanning which corresponded to the neurologic findings. Regarding the size of the lesions, SPECT showed a more extensive involvement than CT in 2 cases. This again was in good agreement with the neurologic findings. Inspite of repeat studies cerebellar diaschisis was only seen in a single case with healed cerebral infarction and hemiplegia of some years' standing. Two patients suffered from migraine and compromised blood flow was identified as suggested by the neurologic findings inspite of a normal CT. (Author)

  7. Scintillators for positron emission tomography

    International Nuclear Information System (INIS)

    Moses, W.W.; Derenzo, S.E.

    1995-09-01

    Like most applications that utilize scintillators for gamma detection, Positron Emission Tomography (PET) desires materials with high light output, short decay time, and excellent stopping power that are also inexpensive, mechanically rugged, and chemically inert. Realizing that this ''ultimate'' scintillator may not exist, this paper evaluates the relative importance of these qualities and describes their impact on the imaging performance of PET. The most important PET scintillator quality is the ability to absorb 511 keV photons in a small volume, which affects the spatial resolution of the camera. The dominant factor is a short attenuation length (≤ 1.5 cm is required), although a high photoelectric fraction is also important (> 30% is desired). The next most important quality is a short decay time, which affects both the dead time and the coincidence timing resolution. Detection rates for single 511 keV photons can be extremely high, so decay times ≤ 500 ns are essential to avoid dead time losses. In addition, positron annihilations are identified by time coincidence so ≤5 ns fwhm coincidence pair timing resolution is required to identify events with narrow coincidence windows, reducing contamination due to accidental coincidences. Current trends in PET cameras are toward septaless, ''fully-3D'' cameras, which have significantly higher count rates than conventional 2-D cameras and so place higher demands on scintillator decay time. Light output affects energy resolution, and thus the ability of the camera to identify and reject events where the initial 511 keV photon has undergone Compton scatter in the patient. The scatter to true event fraction is much higher in fully-3D cameras than in 2-D cameras, so future PET cameras would benefit from scintillators with a 511 keV energy resolution < 10--12% fwhm

  8. Positron Emission Tomography (PET)

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hines, H.

    2001-01-01

    ADAC Laboratories has two main imaging strengths: PET and Gamma Cameras. PET's three-dimensional imaging of metabolic function is used in oncology, with emerging opportunties in cardiology, genetic mapping and pharmaceuticals research. In oncology, PET imaging can provide comprehensive and accurate staging information which is not available from CT or MRI. In some cases, this information can lead to modification of treatment, for example from an aggressive approach to one of palliation. The SKYLight is the world's first and only gantry-free camera. It is a dual-detector variable angle camera designed for high throughput, with unsurpassed openness and patient access. (orig.)

  9. Assessment of left ventricular function by gated cardiac blood-pool emission computed tomography using a rotating gamma camera

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa; Honda, Minoru

    1991-01-01

    To elucidate the usefulness of gated cardiac blood-pool single photon emission CT (SPECT) with Tc-99m for the evaluation of left ventricular (LV) global and regional functions, 18 patients with coronary artery disease were studied. Thirty-two gated projection images were obtained over 360-degree at 16 frames per cardiac cycle. As LV volume was calculated by integrating the numbers of voxels which constituted LV and multiplying by the volume of a single voxel (0.1143 ml), we performed phantom studies to determine the appropriate cut-off level to detect LV outline. These cut-off levels were affected by the background activity and organ volume itself. So we constructed Volume-Cut-Level-Curve at each background activity. In clinical studies, short axis images which constituted LV were selected and provisional LV volumes were calculated at the cut-off levels of 45, 50 and 55%. These volumes were plotted on the Volume-Cut-Level-Curve and the true cut-off levels were obtained to calculate LV end-diastolic or end-systolic volume (EDV, ESV). The cut-off levels were different at every patient and ED or ES. EDV, ESV and LV ejection fraction obtained by SPECT were correlatd well with those obtained by contrast ventriculography (LVG) (r=0.89, 0.94, 0.94 each, p<0.01). For the LV wall motion analysis, LVGs obtained at two projections were compared with SPECT or gated cardiac blood-pool planar imaging (Planar) in 5 segments. In addition to visual comparison, wall motion scores (WMS) based on the degree of wall motion abnormality were calculated in each segment. Correlation of WMS between LVG and SPECT (r=0.84) was significantly (p<0.01) superior to that between LVG and Planar (r=0.62). Especially in SPECT, wall motion analyses at septal and infero-posterior segments were superior to those in Planar. Although gated SPECT requires relatively long time to perform, it is a useful method to detect LV global and regional functions. (author)

  10. Single photon emission computerized tomography (SPECT)

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as 123 I and 99 Tc m that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  11. Single photon emission computerized tomography (SPECT)

    Energy Technology Data Exchange (ETDEWEB)

    Ganatra, R D

    1993-12-31

    Tomography in nuclear medicine did not originate after the introduction of X-ray computerized tomography (CT). Even in the days of rectilinear scanner, tomography was attempted with multiple detector heads rotating around the patient, but the counts at each plane were never very high to obtain a satisfactory image. A high resolution focusing collimator can look at different depths but taking several slices in one projection was a time consuming process. Rectilinear scanners lose lot of counts in the collimator to look at one point, at on time, in one plane. It is true that attempts to do tomography with gamma camera really got a boost after the success of CT. By that time, algorithms for doing reconstruction of images also were highly refined and for advanced. Clinical application of SPECT has become widespread now, because of the development of suitable radiopharmaceuticals and improvement in instrumentation. The SPECT provides a direct measure of regional organ function and is performed with nuclides such as {sup 123}I and {sup 99}Tc{sup m} that emit a mono-image photon during their decay. SPECT is far less expensive than positron emission tomography

  12. Instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.; Derenzo, S.E.; Huesman, R.H.

    1984-01-01

    Positron emission tomography with a spatial resolution of 2 mm full width at half maximum for quantitation in regions of interest 4 mm in diameter will become possible with the development of detectors that achieve ultrahigh resolution. Improved resolution will be possible using solid-state photodetectors for crystal identification or photomultiplier tubes with many small electron multipliers. Temporal resolution of 2 seconds and gating of cyclic events can be accomplished if statistical requirements are met. The major physical considerations in achieving high-resolution positron emission tomography are the degradation in resolution resulting from positron range, emission angle, parallax error, detector sampling density, the sensitivity of various detector materials and packing schemes, and the tradeoff between temporal resolution and statistical accuracy. The accuracy of data required for physiological models depends primarily on the fidelity of spatial sampling independent of statistical constraints

  13. Preliminary results with gamma-tomography using a rotating gammacamera

    International Nuclear Information System (INIS)

    Raynaud, C.; Soussaline, F.; Todd-Pokropek, A.; Zurowski, S.; Kellershohn, C.

    1980-03-01

    In order to perform single photon emission tomography also known as gamma-tomography (GT). We have used a system comprising a GE 400 T coupled to an Informatek Simis 3 computer. Up to a maximum of 64 transverse axial tomograms can be reconstructed and then sorted to obtain sagittal and frontal slices through the volume reconstructed. Of the 48 patients so far studied, 29 had brain scans for tumor and 29 liver scans for tumor, abcess or cirrhosis. The results obtained are indicated

  14. Emission tomography system

    International Nuclear Information System (INIS)

    Phelps, M.E.; Hoffman, E.J.; Williams, C.W.; Burgiss, S.G.

    1983-01-01

    In the present invention a positron emission tomographic system is provided in which the random photon coincidence background is determined for the lines of sight along which the positron annihiliations are located. The circuitry is arranged so that this background may be subtracted almost simultaneously from the total photon coincidence measurement, or may be stored in a temporary memory for latter subtraction. In this system, an appropriate coincidence resolution time is selected and coincidences of photons detected at 180 degree opposed detectors within the time resolution are recorded as the overall coincidence count. This total count includes a source(true events) count plus a background(random coincidences) count. The background count is determined by measuring photons detected at these same sets of photon detectors and employing the same coincidence resolution period, where the signals from one set of detectors are passed through a delay longer in time than this resolution period

  15. Detectors for high resolution dynamic positron emission tomography

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.; Huesman, R.H.

    1985-01-01

    Tomography is the technique of producing a photographic image of an opaque specimen by transmitting a beam of x-rays or gamma rays through the specimen onto an adjacent photographic film. The image results from variations in thickness, density, and chemical composition, of the specimen. This technique is used to study the metabolism of the human brain. This article examines the design of equipment used for high resolution dynamic positron emission tomography. 27 references, 5 figures, 3 tables

  16. Hybrid Gama Emission Tomography (HGET): FY16 Annual Report

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Erin A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Smith, Leon E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wittman, Richard S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Campbell, Luke W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Deshmukh, Nikhil S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zalavadia, Mital A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Batie, Margo A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Mozin, Vladimir V. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-02-01

    Current International Atomic Energy Agency (IAEA) methodologies for the verification of fresh low-enriched uranium (LEU) and mixed oxide (MOX) fuel assemblies are volume-averaging methods that lack sensitivity to individual pins. Further, as fresh fuel assemblies become more and more complex (e.g., heavy gadolinium loading, high degrees of axial and radial variation in fissile concentration), the accuracy of current IAEA instruments degrades and measurement time increases. Particularly in light of the fact that no special tooling is required to remove individual pins from modern fuel assemblies, the IAEA needs new capabilities for the verification of unirradiated (i.e., fresh LEU and MOX) assemblies to ensure that fissile material has not been diverted. Passive gamma emission tomography has demonstrated potential to provide pin-level verification of spent fuel, but gamma-ray emission rates from unirradiated fuel emissions are significantly lower, precluding purely passive tomography methods. The work presented here introduces the concept of Hybrid Gamma Emission Tomography (HGET) for verification of unirradiated fuels, in which a neutron source is used to actively interrogate the fuel assembly and the resulting gamma-ray emissions are imaged using tomographic methods to provide pin-level verification of fissile material concentration.

  17. Positron emission tomography takes lead

    International Nuclear Information System (INIS)

    Simms, R.

    1989-01-01

    Positron emission tomography (PET)'s ability to detect functional abnormalities before they manifest anatomically is examined and some of its most common applications are outlined. It is emphasised that when PET facility and Australian Nuclear Science and Technology Organization's national cyclotron are established at the Royal Prince Alfred Hospital, the availability of short-lived tracers such as oxygen 15, nitrogen 13 and fluorine 18 would improve the specificity of tests(e.g. for brain tumors or cardiac viability) further. Construction of the cyclotron will start shortly and is due to be completed and operating by the end of 1991

  18. Fundamentals of positron emission tomography

    International Nuclear Information System (INIS)

    Ostertag, H.

    1989-01-01

    Positron emission tomography is a modern radionuclide method of measuring physiological quantities or metabolic parameters in vivo. The methods is based on: (1) Radioactive labelling with positron emitters; (2) the coincidence technique for the measurement of the annihilation radiation following positron decay; (3) analysis of the data measured using biological models. The basic aspects and problems of the method are discussed. The main fields of future research are the synthesis of new labelled compounds and the development of mathematical models of the biological processes to be investigated. (orig.) [de

  19. Single-photon emission computed tomography

    International Nuclear Information System (INIS)

    Budinger, T.F.

    1986-01-01

    Single photon tomography dates from the early 1960's when the idea of emission transverse section tomography was presented by Kuhl and Edwards. They used a rectilinear scanner and analogue back-projection methods to detect emissions from a series of sequential positions transverse to the cephaldcaudad axis of the body. This chapter presents an explanation of emission tomography by describing longitudinal and transverse section tomography. In principle all modes of tomography can be considered under the general topic of coded apertures wherein the code ranges from translation of a pinhole collimator to rotation of a parallel hole or focused collimator array

  20. Cardiac blood pool emission tomography

    International Nuclear Information System (INIS)

    Itti, R.; Philippe, L.; Lorgeron, J.M.; Charbonnier, B.; Raynaud, P.; Brochier, M.

    1983-01-01

    After blood pool labeling using technetium-99m, a series of cardiac pictures is acquired during the rotation of a gamma-camera about the patient. Computer processing leads to reconstruction of various tomographic slices from the original planar projection. Electrocardiographic gating selects the different phases of the cardiac cycle. Individual slices through the left ventricular region are added in order to provide ''thick'' slices on which global and regional parameters of the left ventricular function can be determined. Due to the proportionality existing between count rates and labeled blood volumes, any geometrical model can be avoided. The delineation of regions of interest for count integration is made easier due to the absence of superimposition of structures; no correction for background is necessary. Tomography thus appears to be more consistent and more accurate than the classical methods using planar projections. In addition, right ventricular morphological and kinetic studies can be performed in the same conditions as for the left ventricle [fr

  1. Sparse image representation for jet neutron and gamma tomography

    Energy Technology Data Exchange (ETDEWEB)

    Craciunescu, T. [EURATOM-MEdC Association, Institute for Laser, Plasma and Radiation Physics, Bucharest (Romania); Kiptily, V. [EURATOM/CCFE Association, Culham Science Centre, Abingdon (United Kingdom); Murari, A. [Consorzio RFX, Associazione EURATOM-ENEA per la Fusione, Padova (Italy); Tiseanu, I.; Zoita, V. [EURATOM-MEdC Association, Institute for Laser, Plasma and Radiation Physics, Bucharest (Romania)

    2013-10-15

    Highlights: •A new tomographic method for the reconstruction of the 2-D neutron and gamma emissivity on JET. •The method is based on the sparse representation of the reconstructed image in an over-complete dictionary. •Several techniques, based on a priori information are used to regularize this highly limited data set tomographic problem. •The proposed method provides good reconstructions in terms of shapes and resolution. -- Abstract: The JET gamma/neutron profile monitor plasma coverage of the emissive region enables tomographic reconstruction. However, due to the availability of only two projection angles and to the coarse sampling, tomography is a highly limited data set problem. A new reconstruction method, based on the sparse representation of the reconstructed image in an over-complete dictionary, has been developed and applied to JET neutron/gamma tomography. The method has been tested on JET experimental data and significant results are presented. The proposed method provides good reconstructions in terms of shapes and resolution.

  2. Positron emission tomography of the heart

    Energy Technology Data Exchange (ETDEWEB)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease.

  3. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Schelbert, H.R.; Phelps, M.E.; Kuhl, D.E.

    1979-01-01

    Positron emission computed tomography (PCT) represents an important new tool for the noninvasive evaluation and, more importantly, quantification of myocardial performance. Most currently available techniques permit assessment of only one aspect of cardiac function, i.e., myocardial perfusion by gamma scintillation camera imaging with Thallium-201 or left ventricular function by echocardiography or radionuclide angiocardiography. With PCT it may become possible to study all three major segments of myocardial performance, i.e., regional blood flow, mechanical function and, most importantly, myocardial metabolism. Each of these segments can either be evaluated separately or in combination. This report briefly describes the principles and technological advantages of the imaging device, reviews currently available radioactive tracers and how they can be employed for the assessment of flow, function and metabolism; and, lastly, discusses possible applications of PCT for the study of cardiac physiology or its potential role in the diagnosis of cardiac disease

  4. Development of novel emission tomography system

    Science.gov (United States)

    Fu, Geng

    In recent years, small animals, such as mice and rats, have been widely used as subjects of study in biomedical research while molecular biology and imaging techniques open new opportunities to investigate disease model. With the help of medical imaging techniques, researchers can investigate underlying mechanisms inside the small animal, which are useful for both early diagnosis and treatment monitoring. Based on tracer principle single photon emission computed tomography (SPECT) has increased popularity in small animal imaging due to its higher spatial resolution and variety of single-photon emitting radionuclides. Since the image quality strongly depends on the detector properties, both scintillation and semiconductor detectors are under active investigation for high resolution X-ray and gamma ray photon detection. The desired detector properties include high intrinsic spatial resolution, high energy resolution, and high detection efficiency. In this thesis study, we have made extensive efforts to develop novel emission tomography system, and evaluate the use of both semiconductor and ultra-high resolution scintillation detectors for small animal imaging. This thesis work includes the following three areas. Firstly, we have developed a novel energy-resolved photon counting (ERPC) detector. With the benefits of high energy resolution, high spatial resolution, flexible detection area, and a wide dynamic range of 27--200keV, ERPC detector is well-suited for small animal SPECT applications. For prototype ERPC detector excellent imaging (˜350microm) and spectroscopic performance (4keV Co-57 122keV) has been demonstrated in preliminary study. Secondly, to further improve spatial resolution to hundred-micron level, an ultra-high resolution Intensified EMCCD (I-EMCCD) detector has been designed and evaluated. This detector consists of the newly developed electron multiplying CCD (EMCCD) sensor, columnar CsI(Tl) scintillator, and an electrostatic de-magnifier (DM) tube

  5. Diagnostic value of sectional images obtained by emission tomography

    International Nuclear Information System (INIS)

    Roucayrol, J.C.

    1981-01-01

    It is now possible to obtain clear images of the various planes in and around a structure with ultra-sounds (echotomography), X-rays (computerized tomography) and recently, gamma-rays from radioactive substances (emission tomography). Axial transverse tomography, which is described here, is to conventional scintigraphy what CT scan is to radiography. It provides images of any structure capable of concentrating sufficiently a radioactive substance administered intravenously. These images are perpendicular to the longitudinal axis of the body. As shown by examples in the liver, lungs and myocardium, lesions which had passed unnoticed with other exploratory techniques can now be demonstrated, and the location, shape and extension of known lesions can be more accurately assessed. Emission tomography already has its place in modern diagnostic procedures side by side with echotomography and CT scan [fr

  6. Energy spectrum of lightning gamma emission

    Energy Technology Data Exchange (ETDEWEB)

    Chubenko, A.P. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Karashtin, A.N. [Research Radiophysics Institute, Nizhny Novgorod (Russian Federation); Ryabov, V.A., E-mail: ryabov@x4u.lebedev.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shepetov, A.L. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Antonova, V.P.; Kryukov, S.V. [Ionosphere Institute, Almaty (Kazakhstan); Mitko, G.G.; Naumov, A.S.; Pavljuchenko, L.V. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Ptitsyn, M.O., E-mail: ptitsyn@lpi.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shalamova, S.Ya. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shlyugaev, Yu.V. [Research Radiophysics Institute, Nizhny Novgorod (Russian Federation); Vildanova, L.I. [Tien-Shan Mountain Cosmic Ray Station, Almaty (Kazakhstan); Zybin, K.P. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Gurevich, A.V., E-mail: alex@lpi.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation)

    2009-08-10

    The results of gamma emission observations obtained during thunderstorms at Tien-Shan Mountain Cosmic Ray Station are presented. The energy spectrum radiation of the stepped leader gamma radiation is measured. The total energy of stepped leader emitted in gamma rays is estimated as 10{sup -3}-10{sup -2} J. The experimental results are in an agreement with the runaway breakdown mechanism.

  7. Energy spectrum of lightning gamma emission

    International Nuclear Information System (INIS)

    Chubenko, A.P.; Karashtin, A.N.; Ryabov, V.A.; Shepetov, A.L.; Antonova, V.P.; Kryukov, S.V.; Mitko, G.G.; Naumov, A.S.; Pavljuchenko, L.V.; Ptitsyn, M.O.; Shalamova, S.Ya.; Shlyugaev, Yu.V.; Vildanova, L.I.; Zybin, K.P.; Gurevich, A.V.

    2009-01-01

    The results of gamma emission observations obtained during thunderstorms at Tien-Shan Mountain Cosmic Ray Station are presented. The energy spectrum radiation of the stepped leader gamma radiation is measured. The total energy of stepped leader emitted in gamma rays is estimated as 10 -3 -10 -2 J. The experimental results are in an agreement with the runaway breakdown mechanism.

  8. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Mathis, C.A.; Moyer, B.R.; Huesman, R.H.; Derenzo, S.E.

    1983-01-01

    Positron emission tomography (PET) offers the opportunity to noninvasively measure heart muscle blood perfusion, oxygen utilization, metabolism of fatty acids, sugars and amino acids. This paper reviews physiological principles which are basic to PET instrumentation for imaging the heart and gives examples of the application of positron emission tomography for measuring myocardial flow and metabolism. 33 references, 11 figures, 1 table

  9. High-precision gamma-ray spectroscopy of 82Rb and 72As, two important medical isotopes used in positron emission tomography

    Science.gov (United States)

    Nino, Michael; McCutchan, E.; Smith, S.; Sonzogni, A.; Muench, L.; Greene, J.; Carpenter, M.; Zhu, S.; Lister, C.

    2015-10-01

    Both 82Rb and 72As are very important medical isotopes used in imaging procedures, yet their full decay schemes were last studied decades ago using low-sensitivity detection systems; high quality decay data is necessary to determine the total dose received by the patient, the background in imaging technologies, and shielding requirements in production facilities. To improve the decay data of these two isotopes, sources were produced at the Brookhaven Linac Isotope Producer (BLIP) and then the Gammasphere array, consisting of 89 Compton-suppressed HPGe detectors, at Argonne National Laboratory was used to analyze the gamma-ray emissions from the daughter nuclei 82 Kr and 72 Ge. Gamma-ray singles and coincidence information were recorded and analyzed using Radware Gf3m software. Significant revisions were made to the level schemes including the observation of many new transitions and levels as well as a reduction in uncertainty on measured γ-ray intensities and deduced β-feedings. The new decay schemes as well as their impact on dose calculations will be presented. DOE Isotope Program is acknowledged for funding ST5001030. Work supported by the U.S. DOE under Grant No. DE-FG02-94ER40848 and Contract Nos. DE-AC02-98CH10946 and DE-AC02-06CH11357 and by the Science Undergraduate Laboratory Internships Program (SULI).

  10. Improved positron emission tomography camera

    International Nuclear Information System (INIS)

    Mullani, N.A.

    1986-01-01

    A positron emission tomography camera having a plurality of rings of detectors positioned side-by-side or offset by one-half of the detector cross section around a patient area to detect radiation therefrom, and a plurality of scintillation crystals positioned relative to the photomultiplier tubes whereby each tube is responsive to more than one crystal. Each alternate crystal in the ring may be offset by one-half or less of the thickness of the crystal such that the staggered crystals are seen by more than one photomultiplier tube. This sharing of crystals and photomultiplier tubes allows identification of the staggered crystal and the use of smaller detectors shared by larger photomultiplier tubes thereby requiring less photomultiplier tubes, creating more scanning slices, providing better data sampling, and reducing the cost of the camera. (author)

  11. Positron emission tomography and migraine

    International Nuclear Information System (INIS)

    Chabriat, H.

    1992-01-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT 2 serotonin receptors can be studied in migraine patients with PET

  12. Positron emission tomography basic sciences

    CERN Document Server

    Townsend, D W; Valk, P E; Maisey, M N

    2003-01-01

    Essential for students, science and medical graduates who want to understand the basic science of Positron Emission Tomography (PET), this book describes the physics, chemistry, technology and overview of the clinical uses behind the science of PET and the imaging techniques it uses. In recent years, PET has moved from high-end research imaging tool used by the highly specialized to an essential component of clinical evaluation in the clinic, especially in cancer management. Previously being the realm of scientists, this book explains PET instrumentation, radiochemistry, PET data acquisition and image formation, integration of structural and functional images, radiation dosimetry and protection, and applications in dedicated areas such as drug development, oncology, and gene expression imaging. The technologist, the science, engineering or chemistry graduate seeking further detailed information about PET, or the medical advanced trainee wishing to gain insight into the basic science of PET will find this book...

  13. Positron emission tomography with Positome, 2

    International Nuclear Information System (INIS)

    Nukui, Hideaki; Yamamoto, Y.L.; Thompson, C.J.; Feindel, W.

    1979-01-01

    Positron emission tomography with Positome II using 68 Ga-EDTA was performed in cases with brain tumor and cerebral arteriovenous malformation. A significant focal uptake in static study and hemodynamic changes in dynamic study were noted in all cases except one case with intracranial lipoma. Comparing this method with sup(99m) Tc-pertechnetate cerebral image study and computerized axial tomography, the diagnostic rate for detecting brain tumor was almost equal in all of these three methods. However, detecting and localizing was easier and clearer in static positron emission tomography with 68 Ga-EDTA than in sup(99m) Tc-pertechnetate cerebral image and computerized axial tomography without infusion of contrast medium. Furthermore, static positron emission tomography with 68 Ga-EDTA was superior to computerized axial tomography without infusion of contrast medium for detecting cerebral arteriovenous malformation. Concerning dynamic positron emission tomography with 68 Ga-EDTA, semiquantitative values obtained by this method correlated well with findings of computerized axial tomography and was thought to be more precise and in detail than the findings of sup(99m) Tc-pertechnetate cerebral image study. Summation of the previous studies about dynamic positron emission tomography with 77 Kr in occlusive cerebrovascular disease is also reported. In conclusion, static positron emission tomography with 68 Ga-EDTA is a very useful diagnostic method for detecting and localizing brain tumor and cerebral arteriovenous malformation without any attendant complications. Furthermore, a good combination of static and dynamic positron emission tomography and computerized axial tomography appear to be outstandingly effective for not only detecting the lesion but also understanding the pathophysiological aspect in cases with various intracranial lesions. (author)

  14. Positron emission tomography in oncology

    International Nuclear Information System (INIS)

    Lecomte, R.; Bentourkia, M.; Benard, F.

    2002-01-01

    Positron Emission Tomography is a sophisticated molecular imaging technique, using a special scanner, that displays the functional status of tissues in the body at the cellular level (their metabolism). It is a diagnostic scan that provides the physician with information not available with traditional anatomic studies such as CT or MRI. PET can detect changes in cell function (disease) long before they are evident as physical (anatomic) changes seen on CT or MRI. In this way PET can add important information about many diseases allowing the physician to make a diagnosis often much earlier than with anatomic imaging techniques such as CT or MRI alone. In addition, in cases where an abnormality is noted on CT or MRI, PET can help differentiate benign changes from changes due to disease. PET scanning also typically images the entire body, unlike CT/MRI which is usually broken up into specific limited body section scans. All cells use glucose as an energy source but cancer cells use much more since they are growing much faster and out of control. This is the basis of imaging with F-18 FDG glucose, the radiotracer agent use in a PET oncology study. The abnormal, accelerated glucose used by cancer cells is detected by the PET scanner that processes the emissions from the F-18 FDG glucose by abnormally high levels of metabolism (tumor)

  15. Basic principles of 18F-fluoro-deoxyglucose positron emission tomography

    International Nuclear Information System (INIS)

    Standke, R.

    2002-01-01

    Positron emission tomography uses photons to receive regional information about dynamic, physiologic, and biochemical processes in the living body. A positron decay is measured indirectly by the simultaneous registration of both gamma rays created by the annihilation. The event is counted, if two directly opposite located detectors register gamma rays in coincidence. Unfortunately the detectors of a positron emission tomography system do not register only true coincident events. There are also scattered and random coincidences. Different types of positron tomographs are presented and scintillation crystals, which are in use for positron emission tomography are discussed. The 2D- and 3D-acquisition methods are described as well as preprocessing methods, such as correction for attenuation, scatter and dead time. For quantification the relative parameter standard uptake value (SUV) is explained. Finally hybrid systems, such as combined positron emission tomography/computed tomography scanners and the use of computed tomography data for attenuation correction are introduced. (author)

  16. Simultaneous emission and transmission scanning in positron emission tomography

    International Nuclear Information System (INIS)

    Satoh, Tomohiko; Tanaka, Kazumi; Kitamura, Keishi; Amano, Masaharu; Miura, Shuichi

    2001-01-01

    Examination by PET (positron emission tomography) scanning, following the dosage of 2-deoxy- 18 F fluoro-D-glucose (FDG), is positively utilized for the diagnosis of cancers, rather than for the purpose of studies. This is because the examination by FDG-PET (PET scanning following the dosage of FDG) ensures higher efficiency in discrimination of cancers, than conventional CT and PET. The method of whole body scanning by PET scanning following the dosage of FDG is effectively utilized not only for discrimination cancers, but also for determining the degree of malignancy of tumors and evaluating the methods of treatment of cancers. In conventional methods for examining the degree of malignancy of tumors and evaluating the methods of cancer treatment, it is necessary to correct for the gamma-ray attenuation, which requires a longer time for examination, increasing the physical and psychological pains of the patients. We have installed the simultaneous emission and transmission scanning capability into the HEADTOME-V of the Shimadzu SET-2000W Series positron emission tomographic scanning instruments, to establish an instrument that permits FDG-PET whole body scanning in actual clinical fields, with minimized physical and psychological pains of patients concerned, yet ensuring an outstandingly high examination efficiency. This report also presents some data obtained by this newly developed instrument and those obtained in practical applications. (author)

  17. Method of multiplanar emission tomography and apparatus therefor

    International Nuclear Information System (INIS)

    Gottschalk, S.C.; Smith, K.A.; Wake, R.H.

    1981-01-01

    A method of emission tomography using a gamma camera and a rotating collimator having an array of a large number of slanted, small diameter holes. A planar projection corresponding to each angular orientation assumed by the collimator is recorded. From these series of planar projections, a three-dimensional simulation model is reconstructed by an iterative algorithm which approximates the emitting object. The simulated model comprises multiple separable planes

  18. Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera.

    Science.gov (United States)

    Shiraishi, Shinya; Sakamoto, Fumi; Tsuda, Noriko; Yoshida, Morikatsu; Tomiguchi, Seiji; Utsunomiya, Daisuke; Ogawa, Hisao; Yamashita, Yasuyuki

    2015-01-01

    Myocardial perfusion imaging (MPI) may fail to detect balanced ischemia. We evaluated myocardial perfusion reserve (MPR) using Tl dynamic single-photon emission computed tomography (SPECT) and a novel cadmium zinc telluride (CZT) camera for predicting 3-vessel or left main coronary artery disease (CAD). METHODS AND RESULTS: A total of 55 consecutive patients with suspected CAD underwent SPECT-MPI and coronary angiography. The MPR index was calculated using the standard 2-compartment kinetic model. We analyzed the utility of MPR index, other SPECT findings, and various clinical variables. On multivariate analysis, MPR index and history of previous myocardial infarction (MI) predicted left main and 3-vessel disease. The area under the receiver operating characteristic curve was 0.81 for MPR index, 0.699 for history of previous MI, and 0.86 for MPR index plus history of previous MI. MPR index ≤1.5 yielded the highest diagnostic accuracy. Sensitivity, specificity, and accuracy were 86%, 78%, and 80%, respectively, for MPR index, 64%, 76%, 73% for previous MI, and 57%, 93%, and 84% for MPR index plus history of previous MI. Quantification of MPR using dynamic SPECT and a novel CZT camera may identify balanced ischemia in patients with left main or 3-vessel disease.

  19. Positron emission tomography in neuropsychology.

    Science.gov (United States)

    Heiss, W D; Herholz, K; Pawlik, G; Wagner, R; Wienhard, K

    1986-01-01

    By positron emission tomography (PET) of 18F-2-fluoro-2-deoxy-D-glucose (FDG) local cerebral metabolic rate for glucose (LCMRGl) can be measured in man. Normal values in cerebral cortex and basal ganglia range from 35 to 50 mumol/100 g/min, the values in gray matter structures of the posterior fossa were 25-30 mumol/100 g/min, the lowest LCMRGl was found in the white matter (15-20 mumol/100 g/min). During sensory stimulation by various modalities functional activation increases LCMRGl in the respective special areas, while sleep decreases metabolic rate in all cortical and basal gray matter structures. In many neurological disorders CMRGl is altered in a disease-specific pattern. In dementia of the Alzheimer type CMRGl is impaired even in early stages with accentuation in the parieto-temporal cortex, while in multi-infarct dementia glucose uptake is mainly reduced in the multifocal small infarcts. In Huntington's chorea the most conspicuous changes are found in the caudate nucleus and putamen. In cases of focal lesions (e.g. ischemic infarcts) metabolic disturbances extend far beyond the site of the primary lesion and inactivation of metabolism is found in intact brain structures far away from the anatomical lesion. Additional applications of PET include determination of the metabolism of various substrates, of protein synthesis, of function and distribution of receptors, of tumor growth and of the distribution of drugs as well as the measurement of oxygen consumption, blood flow and blood volume.

  20. Positron emission tomography in epilepsy

    International Nuclear Information System (INIS)

    Hosokawa, Shinichi; Kato, Motohiro; Otsuka, Makoto; Kuwabara, Yasuo; Ichiya, Yuichi; Goto, Ikuo

    1989-01-01

    Positron emission tomography (PET) was performed with the 18 F-fluoro-deoxy-glucose method on 29 patients with epilepsy (generalized epilepsy, 4; partial epilepsy, 24; undetermined type, 1). The subjects were restricted to patients with epilepsy without focal abnormality on X-CT. All the patients with generalized epilepsy showed a normal pattern on PET. Fourteen out of the 24 patients with partial epilepsy and the 1 with epilepsy of undermined type showed focal hypometabolism on PET. The hypometabolic zone was localized in areas including the temporal cortex in 11 patients, frontal in 2 and thalamus in 1. The location of hypometabolic zone and that of interictal paroxysmal activity on EEG were well correlated in most patients. The patients with poorly-controlled seizure showed a higher incidence of PET abnormality (12 out of 13) than those with well-controlled seizures (2 out of 11). The incidence of abnormality on PET and MRI and the location of both abnormality were not necessarily coincident. These results indicated that the PET examination in epilepsy provides valuable information about the location of epileptic focus, and that the findings on PET in patients with partial epilepsy may be one of the good indicators about the intractability of partial epilepsy, and that PET and MRI provide complementary information in the diagnosis of epilepsy. (author)

  1. Radiopharmaceutical chemistry for positron emission tomography

    NARCIS (Netherlands)

    Elsinga, PH

    Radiopharmaceutical chemistry includes the selection, preparation, and preclinical evaluation of radiolabeled compounds. This paper describes selection criteria for candidates for positron emission tomography (PET) investigations. Practical aspects of nucleophilic and electrophilic

  2. Development of emission computed tomography in Japan

    International Nuclear Information System (INIS)

    Tanaka, E.

    1984-01-01

    Two positron emission computed tomography (PCT) devices developed in Japan are described. One is for head and the other for wholebody. The devices show fairly quantitative images with slight modifications of the existing algorithms because they were developed based on filtered back-projection. The PCT device seems to be better than the single photon emission computed tomography (SPECT) since it provides adequade compensation for photon attenuation in patients. (M.A.C.) [pt

  3. Dynamic emission tomography of regional cerebral blood flow

    International Nuclear Information System (INIS)

    Lassen, N.A.

    1984-01-01

    The author reviews three tomographic methods for measuring the regional cerebral blood flow: single photon transmission tomography; dual photon emission tomography; and single photon emission tomography. The latter technique is discussed in detail. (Auth.)

  4. Fluorodeoxyglucose Positron Emission Tomography-Computed Tomography in Disseminated Cryptococcosis.

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography-computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm.

  5. Attenuation Correction Strategies for Positron Emission Tomography/Computed Tomography and 4-Dimensional Positron Emission Tomography/Computed Tomography

    OpenAIRE

    Pan, Tinsu; Zaidi, Habib

    2013-01-01

    This article discusses attenuation correction strategies in positron emission tomography/computed tomography (PET/CT) and 4 dimensional PET/CT imaging. Average CT scan derived from averaging the high temporal resolution CT images is effective in improving the registration of the CT and the PET images and quantification of the PET data. It underscores list mode data acquisition in 4 dimensional PET and introduces 4 dimensional CT popular in thoracic treatment planning to 4 dimensional PET/CT. ...

  6. Emission tomography: quantitative aspects in metabolic and physiopathologic studies

    International Nuclear Information System (INIS)

    Yerouchalmi-Soussaline, F.

    1984-11-01

    This thesis presents instrumental and data processing studies developped in emission tomography in man, using gamma and positron emitting tracers. High contrast visualisation of volume distribution of tracers in the organs, kinetic studies and measurements of radioactive concentration or of other clinical parameters necessitate a detailed analysis of all physical factors limiting the accuracy of the measure; therefore, development of adapted imaging devices and data processing techniques, together with models describing correctly the phenomena under study are to be carried out. Thus, in single photon (gamma) emission tomography an image reconstruction strategy is elaborated, based on an analytical model for the ill-posed problem including the attenuation effect. In positron emission tomography, the time-of-flight information combined with the reconstruction technique is used in the design of a first prototype imaging device which performance is presented and evaluated in a clinical environment. Moreover, a priori or a posteriori techniques correcting for Compton diffusion events, limited statistics and limited resolutions, are proposed and discussed for the improvement of regional measurement accuracy, in metabolic and physiopathologic studies [fr

  7. Pre-equilibrium gamma emissions

    International Nuclear Information System (INIS)

    Ghosh, Sudip

    1993-01-01

    Together with the direct reaction and the compound nuclear emissions the pre-equilibrium (PEQ) or pre-compound processes give a fairly complete picture of nuclear reactions induced by light ions at energies of some tens of MeV. PEQ particle emissions covering the higher energy continuum spectra have been investigated in detail both experimentally and theoretically. In contrast, very little work has been done on PEQ γ- emissions. The reason is that in spite of extensive work done on PEQ particle emissions, the mechanism is not yet fully understood. Also, the PEQ γ-emission cross-sections (∼ micro barns) are very small compared to the PEQ particle emission cross-sections (∼ milli barns). Yet apart from the academic interest the understanding of PEQ γ-emissions is important for applied fusion research etc. In this paper the PEQ γ-emissions is discussed and the work done in this field is reviewed. (author). 14 refs

  8. Data analysis in emission tomography using emission-count posteriors

    International Nuclear Information System (INIS)

    Sitek, Arkadiusz

    2012-01-01

    A novel approach to the analysis of emission tomography data using the posterior probability of the number of emissions per voxel (emission count) conditioned on acquired tomographic data is explored. The posterior is derived from the prior and the Poisson likelihood of the emission-count data by marginalizing voxel activities. Based on emission-count posteriors, examples of Bayesian analysis including estimation and classification tasks in emission tomography are provided. The application of the method to computer simulations of 2D tomography is demonstrated. In particular, the minimum-mean-square-error point estimator of the emission count is demonstrated. The process of finding this estimator can be considered as a tomographic image reconstruction technique since the estimates of the number of emissions per voxel divided by voxel sensitivities and acquisition time are the estimates of the voxel activities. As an example of a classification task, a hypothesis stating that some region of interest (ROI) emitted at least or at most r-times the number of events in some other ROI is tested. The ROIs are specified by the user. The analysis described in this work provides new quantitative statistical measures that can be used in decision making in diagnostic imaging using emission tomography. (paper)

  9. Data analysis in emission tomography using emission-count posteriors

    Science.gov (United States)

    Sitek, Arkadiusz

    2012-11-01

    A novel approach to the analysis of emission tomography data using the posterior probability of the number of emissions per voxel (emission count) conditioned on acquired tomographic data is explored. The posterior is derived from the prior and the Poisson likelihood of the emission-count data by marginalizing voxel activities. Based on emission-count posteriors, examples of Bayesian analysis including estimation and classification tasks in emission tomography are provided. The application of the method to computer simulations of 2D tomography is demonstrated. In particular, the minimum-mean-square-error point estimator of the emission count is demonstrated. The process of finding this estimator can be considered as a tomographic image reconstruction technique since the estimates of the number of emissions per voxel divided by voxel sensitivities and acquisition time are the estimates of the voxel activities. As an example of a classification task, a hypothesis stating that some region of interest (ROI) emitted at least or at most r-times the number of events in some other ROI is tested. The ROIs are specified by the user. The analysis described in this work provides new quantitative statistical measures that can be used in decision making in diagnostic imaging using emission tomography.

  10. Positron emission tomography/computed tomography scanning for ...

    African Journals Online (AJOL)

    Background: Although the site of nosocomial sepsis in the critically ill ventilated patient is usually identifiable, it may remain occult, despite numerous investigations. The rapid results and precise anatomical location of the septic source using positron emission tomography (PET) scanning, in combination with computed ...

  11. Photons-based medical imaging - Radiology, X-ray tomography, gamma and positrons tomography, optical imaging; Imagerie medicale a base de photons - Radiologie, tomographie X, tomographie gamma et positons, imagerie optique

    Energy Technology Data Exchange (ETDEWEB)

    Fanet, H.; Dinten, J.M.; Moy, J.P.; Rinkel, J. [CEA Leti, Grenoble (France); Buvat, I. [IMNC - CNRS, Orsay (France); Da Silva, A. [Institut Fresnel, Marseille (France); Douek, P.; Peyrin, F. [INSA Lyon, Lyon Univ. (France); Frija, G. [Hopital Europeen George Pompidou, Paris (France); Trebossen, R. [CEA-Service hospitalier Frederic Joliot, Orsay (France)

    2010-07-01

    This book describes the different principles used in medical imaging. The detection aspects, the processing electronics and algorithms are detailed for the different techniques. This first tome analyses the photons-based techniques (X-rays, gamma rays and visible light). Content: 1 - physical background: radiation-matter interaction, consequences on detection and medical imaging; 2 - detectors for medical imaging; 3 - processing of numerical radiography images for quantization; 4 - X-ray tomography; 5 - positrons emission tomography: principles and applications; 6 - mono-photonic imaging; 7 - optical imaging; Index. (J.S.)

  12. X-Ray-Driven Gamma Emission

    International Nuclear Information System (INIS)

    Carroll, J. J.; Karamian, S. A.; Rivlin, L. A.; Zadernovsky, A. A.

    2001-01-01

    X-ray-driven gamma emission describes processes that may release nuclear energy in a 'clean' way, as bursts of incoherent or coherent gamma rays without the production of radioactive by-products. Over the past decade, studies in this area, as a part of the larger field of quantum nucleonics, have gained tremendous momentum. Since 1987 it has been established that photons could trigger gamma emission from a long-lived metastable nuclear excited state of one nuclide and it appears likely that triggering in other isotopes will be demonstrated conclusively in the near future. With these experimental results have come new proposals for the creation of collective and avalanche-like incoherent gamma-ray bursts and even for the ultimate light source, a gamma-ray laser. Obviously, many applications would benefit from controlled bursts of gamma radiation, whether coherent or not. This paper reviews the experimental results and concepts for the production of gamma rays, driven by externally produced X-rays

  13. Measuring techniques in emission computed tomography

    International Nuclear Information System (INIS)

    Jordan, K.; Knoop, B.

    1988-01-01

    The chapter reviews the historical development of the emission computed tomography and its basic principles, proceeds to SPECT and PET, special techniques of emission tomography, and concludes with a comprehensive discussion of the mathematical fundamentals of the reconstruction and the quantitative activity determination in vivo, dealing with radon transformation and the projection slice theorem, methods of image reconstruction such as analytical and algebraic methods, limiting conditions in real systems such as limited number of measured data, noise enhancement, absorption, stray radiation, and random coincidence. (orig./HP) With 111 figs., 6 tabs [de

  14. Positron emission tomography studies of brain receptors

    International Nuclear Information System (INIS)

    Maziere, B.; Maziere, M.

    1991-01-01

    Probing the regional distribution and affinity of receptors in the brain, in vivo, in human and non human primates has become possible with the use of selective ligands labelled with positron emitting radionuclides and positron emission tomography (PET). After describing the techniques used in positron emission tomography to characterize a ligand receptor binding and discussing the choice of the label and the limitations and complexities of the in vivo approach, the results obtained in the PET studies of various neurotransmission systems: dopaminergic, opiate, benzodiazepine, serotonin and cholinergic systems are reviewed

  15. Positron emission tomography imaging of gene expression

    International Nuclear Information System (INIS)

    Tang Ganghua

    2001-01-01

    The merging of molecular biology and nuclear medicine is developed into molecular nuclear medicine. Positron emission tomography (PET) of gene expression in molecular nuclear medicine has become an attractive area. Positron emission tomography imaging gene expression includes the antisense PET imaging and the reporter gene PET imaging. It is likely that the antisense PET imaging will lag behind the reporter gene PET imaging because of the numerous issues that have not yet to be resolved with this approach. The reporter gene PET imaging has wide application into animal experimental research and human applications of this approach will likely be reported soon

  16. Positron emission tomography in brain function study

    International Nuclear Information System (INIS)

    Wu Hua

    2006-01-01

    Little has been recognized about the advanced brain function. Recent years several new techniques such as event-related potentials, megnetoencephalography, functional magnetic resonance imaging and positron emission tomography (PET) have been used in the study of brain function. The methodology, application study in normal people and clinical patients of PET in brain function are reviewed. (authors)

  17. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Moyer, B.R.; Mathis, C.A.; Ganz, E.; Huesman, R.H.; Derenzo, S.E.

    1982-01-01

    Positron emission tomography (PET) of the heart can measure blood perfusion, metabolism of fatty acids, metabolism of sugars, uptake of amino acids and can quantitate infarction volume. The principles which are basic to PET instrumentation and procedures for quantitative studies of the heart muscle with examples of measurements of myocardial flow and metabolism, are reviewed

  18. Positron emission tomography of the heart

    International Nuclear Information System (INIS)

    Budinger, T.F.; Yano, Y.; Huesman, R.H.; Derenzo, S.E.; Moyer, B.R.; Mathis, C.A.; Ganz, E.; Knittel, B.

    1983-01-01

    Positron emission tomography (PET) of the heart can measure blood perfusion, metabolism of fatty acids, metabolism of sugars, uptake of amino acids and can quantitate infarction volume. The principles are reviewed which are basic to PET instrumentation and procedures for quantitative studies of human physiology with examples of measurements of myocardial flow and metabolism

  19. Is positron emission tomography useful in stroke?

    NARCIS (Netherlands)

    DeReuck, J; Leys, D; DeKeyser, J

    Positron emission tomography (PET) has been widely used in the study of stroke and related cerebrovascular diseases. It has shown the various stages leading to cerebral infarction and defined the significance of the ischaemic penumbra. PET scan can predict the clinical outcome of patients with acute

  20. Positron emission tomography in malignant haematological disease

    NARCIS (Netherlands)

    Schot, Bartholomeus Wilhelmus

    2007-01-01

    Positron emission tomography (PET) is a diagnostic technique with a promising role especially in the haemato-oncology. Although its use in the management ; of malignant lymphoma seems to be established already, much about the true potential and drawbacks of FDG-PET in this disease are still unknown.

  1. Positron emission tomography applied to fluidization engineering

    NARCIS (Netherlands)

    Dechsiri, C; Ghione, A; van de Wiel, F; Dehling, HG; Paans, AMJ; Hoffmann, AC

    The movement of particles in a laboratory fluidized bed has been studied using Positron Emission Tomography (PET). With this non-invasive technique both pulses of various shapes and single tracer particles were followed in 3-D. The equipment and materials used made it possible to label actual bed

  2. Advanced Instrumentation for Positron Emission Tomography [PET

    Science.gov (United States)

    Derenzo, S. E.; Budinger, T. F.

    1985-04-01

    This paper summarizes the physical processes and medical science goals that underlay modern instrumentation design for Positron Emission Tomography. The paper discusses design factors such as detector material, crystalphototube coupling, shielding geometry, sampling motion, electronics design, time-of-flight, and the interrelationships with quantitative accuracy, spatial resolution, temporal resolution, maximum data rates, and cost.

  3. Gamma ray emission from pulsars

    International Nuclear Information System (INIS)

    Salvati, M.; Massaro, E.

    1978-01-01

    A model for the production of gamma rays in a pulsar environment is presented, together with numerical computations fitted to the observations of PSR 0833-45. It is assumed that the primary particles are accelerated close to the star surface and then injected along the open field lines, which cause them to emit curvature radiation. The equation describing the particles' braking is integrated exactly up to the first order in the pulsar rotational frequency, and the transfer problem for the curvature photons is solved with the aberration, the Doppler shif, and the pair production absorption being taken into account. The latter effect is due not only to the transverse component of the magnetic field, but also to the electric field induced by the rotation. The synchrotron radiation emitted by the secondary particles is also included, subject to the 'on-the-spot' approximation. It is found that the observed gamma rays originate in the innermost regions of the magnetosphere, where the open lines' bundle is narrow and the geometrical beaming is effective. As shown by the computed pulse profiles, the duty cycle turns out to be equal to a few percent, comparable to the one of PSR 0833-45. The averaged spectra indicate that a substantial fraction of the primary photons do outlive the interaction with the magnetisphere; furthermore, the agreement in shape with the observational curves suggests that the acceleration output is fiarly close to a monoenergetic beam of particles. (orig.) [de

  4. 21 CFR 892.1200 - Emission computed tomography system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Emission computed tomography system. 892.1200... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1200 Emission computed tomography system. (a) Identification. An emission computed tomography system is a device intended to detect the...

  5. Positron emission tomography - a new approach to brain chemistry

    International Nuclear Information System (INIS)

    Jacobson, H.G.

    1988-01-01

    Positron emission tomography permits examination of the chemistry of the brain in living beings. Until recently, positron emission tomography had been considered a research tool, but it is rapidly moving into clinical practice. This report describes the uses and applications of positron emission tomography in examinations of patients with strokes, epilepsy, malignancies, dementias, and schizophrenia and in basic studies of synaptic neurotransmission

  6. Gamma-ray Emission from Globular Clusters

    Directory of Open Access Journals (Sweden)

    Pak-Hin T. Tam

    2016-03-01

    Full Text Available Over the last few years, the data obtained using the Large Area Telescope (LAT aboard the Fermi Gamma-ray Space Telescope has provided new insights on high-energy processes in globular clusters, particularly those involving compact objects such as MilliSecond Pulsars (MSPs. Gamma-ray emission in the 100 MeV to 10 GeV range has been detected from more than a dozen globular clusters in our galaxy, including 47 Tucanae and Terzan 5. Based on a sample of known gammaray globular clusters, the empirical relations between gamma-ray luminosity and properties of globular clusters such as their stellar encounter rate, metallicity, and possible optical and infrared photon energy densities, have been derived. The measured gamma-ray spectra are generally described by a power law with a cut-off at a few gigaelectronvolts. Together with the detection of pulsed γ-rays from two MSPs in two different globular clusters, such spectral signature lends support to the hypothesis that γ-rays from globular clusters represent collective curvature emission from magnetospheres of MSPs in the clusters. Alternative models, involving Inverse-Compton (IC emission of relativistic electrons that are accelerated close to MSPs or pulsar wind nebula shocks, have also been suggested. Observations at >100 GeV by using Fermi/LAT and atmospheric Cherenkov telescopes such as H.E.S.S.-II, MAGIC-II, VERITAS, and CTA will help to settle some questions unanswered by current data.

  7. Monte Carlo simulation of gamma ray tomography for image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Guedes, Karlos A.N.; Moura, Alex; Dantas, Carlos; Melo, Silvio; Lima, Emerson, E-mail: karlosguedes@hotmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Meric, Ilker [University of Bergen (Norway)

    2015-07-01

    The Monte Carlo simulations of known density and shape object was validate with Gamma Ray Tomography in static experiments. An aluminum half-moon piece placed inside a steel pipe was the MC simulation test object that was also measured by means of gamma ray transmission. Wall effect of the steel pipe due to irradiation geometry in a single pair source-detector tomography was evaluated by comparison with theoretical data. MCNPX code requires a defined geometry to each photon trajectory which practically prevents this usage for tomography reconstruction simulation. The solution was found by writing a program in Delphi language to create input files automation code. Simulations of tomography data by automated MNCPX code were carried out and validated by experimental data. Working in this sequence the produced data needed a databank to be stored. Experimental setup used a Cesium-137 isotopic radioactive source (7.4 × 109 Bq), and NaI(Tl) scintillation detector of (51 × 51) × 10−3 m crystal size coupled to a multichannel analyzer. A stainless steel tubes of 0,154 m internal diameter, 0.014 m thickness wall. The results show that the MCNPX simulation code adapted to automated input file is useful for generating a matrix data M(θ,t), of a computerized gamma ray tomography for any known density and regular shape object. Experimental validation used RMSE from gamma ray paths and from attenuation coefficient data. (author)

  8. Gamma camera based Positron Emission Tomography: a study of the viability on quantification; Tomografia por emissao de positrons com sistemas PET/SPECT: um estudo da viabilidade de quantifizacao

    Energy Technology Data Exchange (ETDEWEB)

    Pozzo, Lorena

    2005-07-01

    Positron Emission Tomography (PET) is a Nuclear Medicine imaging modality for diagnostic purposes. Pharmaceuticals labeled with positron emitters are used and images which represent the in vivo biochemical process within tissues can be obtained. The positron/electron annihilation photons are detected in coincidence and this information is used for object reconstruction. Presently, there are two types of systems available for this imaging modality: the dedicated systems and those based on gamma camera technology. In this work, we utilized PET/SPECT systems, which also allows for the traditional Nuclear Medicine studies based on single photon emitters. There are inherent difficulties which affect quantification of activity and other indices. They are related to the Poisson nature of radioactivity, to radiation interactions with patient body and detector, noise due to statistical nature of these interactions and to all the detection processes, as well as the patient acquisition protocols. Corrections are described in the literature and not all of them are implemented by the manufacturers: scatter, attenuation, random, decay, dead time, spatial resolution, and others related to the properties of each equipment. The goal of this work was to assess these methods adopted by two manufacturers, as well as the influence of some technical characteristics of PET/SPECT systems on the estimation of SUV. Data from a set of phantoms were collected in 3D mode by one camera and 2D, by the other. We concluded that quantification is viable in PET/SPECT systems, including the estimation of SUVs. This is only possible if, apart from the above mentioned corrections, the camera is well tuned and coefficients for sensitivity normalization and partial volume corrections are applied. We also verified that the shapes of the sources used for obtaining these factors play a role on the final results and should be delt with carefully in clinical quantification. Finally, the choice of the region

  9. Multimodal Imaging of Integrin Receptor-Positive Tumors by Bioluminescence, Fluorescence, Gamma Scintigraphy, and Single-Photon Emission Computed Tomography Using a Cyclic RGD Peptide Labeled with a Near-Infrared Fluorescent Dye and a Radionuclide

    Directory of Open Access Journals (Sweden)

    W. Barry Edwards

    2009-03-01

    Full Text Available Integrins, particularly the αvβ3 heterodimers, play important roles in tumor-induced angiogenesis and invasiveness. To image the expression pattern of the αvβ3 integrin in tumors through a multimodality imaging paradigm, we prepared a cyclic RGDyK peptide analogue (LS308 bearing a tetraazamacrocycle 1,4,7,10-tetraazacyclododecane-N, N′, N″, N‴-tetraacetic acid (DOTA and a lipophilic near-infrared (NIR fluorescent dye cypate. The αvβ3 integrin binding affinity and the internalization properties of LS308 mediated by the αvβ3 integrin in 4t1luc cells were investigated by receptor binding assay and fluorescence microscopy, respectively. The in vivo distribution of 111In-labeled LS308 in a 4t1luc tumor-bearing mouse model was studied by fluorescence, bioluminescence, planar gamma, and single-photon emission computed tomography (SPECT. The results show that LS308 has high affinity for αvβ3 integrin and internalized preferentially via the αvβ3 integrin-mediated endocytosis in 4t1luc cells. We also found that LS308 selectively accumulated in αvβ3-positve tumors in a receptor-specific manner and was visualized by the four imaging methods. Whereas the endogenous bioluminescence imaging identified the ensemble of the tumor tissue, the fluorescence and SPECT methods with the exogenous contrast agent LS308 reported the local expression of αvβ3 integrin. Thus, the multimodal imaging approach could provide important complementary diagnostic information for monitoring the efficacy of new antiangiogenic drugs.

  10. Positron Emission Tomography imaging with the SmartPET system

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom)], E-mail: cooperrj@ornl.gov; Boston, A.J.; Boston, H.C.; Cresswell, J.R.; Grint, A.N.; Harkness, L.J.; Nolan, P.J.; Oxley, D.C.; Scraggs, D.P.; Mather, A.R. [Department of Physics, University of Liverpool, Liverpool, Merseyside L69 7ZE (United Kingdom); Lazarus, I.; Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington, Cheshire WA4 4AD (United Kingdom)

    2009-07-21

    The Small Animal Reconstruction Tomograph for Positron Emission Tomography (SmartPET) project is the development of a small animal Positron Emission Tomography (PET) demonstrator based on the use of High-Purity Germanium (HPGe) detectors and state of the art digital electronics. The experimental results presented demonstrate the current performance of this unique system. By performing high precision measurements of one of the SmartPET HPGe detectors with a range of finely collimated gamma-ray beams the response of the detector as a function of gamma-ray interaction position has been quantified, facilitating the development of parametric Pulse Shape Analysis (PSA) techniques and algorithms for the correction of imperfections in detector performance. These algorithms have then been applied to data from PET imaging measurements using two such detectors in conjunction with a specially designed rotating gantry. In this paper we show how the use of parametric PSA approaches allows over 60% of coincident events to be processed and how the nature and complexity of an event has direct implications for the quality of the resulting image.

  11. Emission computed tomography: methodology and applications

    International Nuclear Information System (INIS)

    Reivich, M.; Alavi, A.; Greenberg, J.; Fowler, J.; Christman, D.; Rosenquist, A.; Rintelmann, W.; Hand, P.; MacGregor, R.; Wolf, A.

    1980-01-01

    A technique for the determination of local cerebral glucose metabolism using positron emission computed tomography is described as an example of the development of use of this methodology for the study of these parameters in man. The method for the determination of local cerebral glucose metabolism utilizes 18 F-2-fluoro-2-deoxyglucose ([ 18 F]-FDG). In this method [ 18 F]-FDG is used as a tracer for the exchange of glucose between plasma and brain and its phosphorylation by hexokinase in the tissue. The labelled product of metabolism, [ 18 F]-FDG phosphate, is essentially trapped in the tissue over the time course of the measurement. The studies demonstrate the potential usefulness of emission computed tomography for the measurement of various biochemical and physiological parameters in man. (Auth.)

  12. Positron emission tomography tracers for imaging angiogenesis

    International Nuclear Information System (INIS)

    Haubner, Roland; Beer, Ambros J.; Wang, Hui; Chen, Xiaoyuan

    2010-01-01

    Position emission tomography imaging of angiogenesis may provide non-invasive insights into the corresponding molecular processes and may be applied for individualized treatment planning of antiangiogenic therapies. At the moment, most strategies are focusing on the development of radiolabelled proteins and antibody formats targeting VEGF and its receptor or the ED-B domain of a fibronectin isoform as well as radiolabelled matrix metalloproteinase inhibitors or α v β 3 integrin antagonists. Great efforts are being made to develop suitable tracers for different target structures. All of the major strategies focusing on the development of radiolabelled compounds for use with positron emission tomography are summarized in this review. However, because the most intensive work is concentrated on the development of radiolabelled RGD peptides for imaging α v β 3 expression, which has successfully made its way from bench to bedside, these developments are especially emphasized. (orig.)

  13. A wavelet phase filter for emission tomography

    International Nuclear Information System (INIS)

    Olsen, E.T.; Lin, B.

    1995-01-01

    The presence of a high level of noise is a characteristic in some tomographic imaging techniques such as positron emission tomography (PET). Wavelet methods can smooth out noise while preserving significant features of images. Mallat et al. proposed a wavelet based denoising scheme exploiting wavelet modulus maxima, but the scheme is sensitive to noise. In this study, the authors explore the properties of wavelet phase, with a focus on reconstruction of emission tomography images. Specifically, they show that the wavelet phase of regular Poisson noise under a Haar-type wavelet transform converges in distribution to a random variable uniformly distributed on [0, 2π). They then propose three wavelet-phase-based denoising schemes which exploit this property: edge tracking, local phase variance thresholding, and scale phase variation thresholding. Some numerical results are also presented. The numerical experiments indicate that wavelet phase techniques show promise for wavelet based denoising methods

  14. Longitudinal emission tomography of thyroid and heart

    International Nuclear Information System (INIS)

    Giessen, J.W. van.

    1986-01-01

    In this thesis three devices are discussed for longitudinal emission tomography, one of which has been developed for myocardial imaging and the other two for thyroid imaging. Longitudinal emission tomography is a technique which enables three-dimensional reconstruction of the radioactivity distribution within an organ from two-dimensional distributions on a detector surface. In Ch. 1 a general survey is given of the clinical environment in which the devices will be used. Ch. 2 discusses a well-known technique for myocardial imaging: seven-pinhole tomography. In Ch. 3 this technique is applied to imaging of the thyroid. Three different reconstruction methods have been applied to the data collected with the system (from phantoms as well as from patients) and the results have been evaluated. Ch. 4 discusses simulation studies which were carried out in order to investigate the potentialities of a time-coded aperture (TCA) system designed for thyroid tomography. In Ch. 5 a prototype is tested of the time coded aperture in a clinical environment. The last chapter presents a comparison between the (thyroid) 7P collimator and the TCA device. (Auth.)

  15. Positron emission tomography in movement disorders

    International Nuclear Information System (INIS)

    Martin, W.R.W.

    1985-01-01

    Positron emission tomography provides a method for the quantitation of regional function within the living human brain. Studies of cerebral metabolism and blood flow in patients with Huntington's disease, Parkinson's disease and focal dystonia have revealed functional abnormalities within substructures of the basal ganglia. Recent developments permit assessment of both pre-synaptic and post-synaptic function ion dopaminergic pathways. These techniques are now being applied to studies of movement disorders in human subjects

  16. Positron emission tomography in movement disorders

    Energy Technology Data Exchange (ETDEWEB)

    Martin, W R.W.

    1985-02-01

    Positron emission tomography provides a method for the quantitation of regional function within the living human brain. Studies of cerebral metabolism and blood flow in patients with Huntington's disease, Parkinson's disease and focal dystonia have revealed functional abnormalities within substructures of the basal ganglia. Recent developments permit assessment of both pre-synaptic and post-synaptic function in dopaminergic pathways. These techniques are now being applied to studies of movement disorders in human subjects.

  17. Positron emission tomography imaging--technical considerations

    International Nuclear Information System (INIS)

    Muehllehner, G.; Karp, J.S.

    1986-01-01

    Positron imaging instrumentation has improved rapidly in the last few years. Scanners currently under development are beginning to approach fundamental limits set by positron range and noncolinearity effects. This report reviews the latest developments in positron emission tomography (PET) instrumentation, emphasizing the development of coding schemes that reduce the complexity and cost of high-resolution scanners. The relative benefits of using time-of-flight (TOF) information is discussed as well. 68 references

  18. Physics and instrumentation of emission computed tomography

    International Nuclear Information System (INIS)

    Links, J.M.

    1986-01-01

    Transverse emission computed tomography can be divided into two distinct classes: single photon emission computed tomography (SPECT) and positron emission tomography (PET). SPECT is usually accomplished with specially-adapted scintillation cameras, although dedicated SPECT scanners are available. The special SPECT cameras are standard cameras which are mounted on gantries that allow 360 degree rotation around the long axis of the head or body. The camera stops at a number of angles around the body (usually 64-128), acquiring a ''projection'' image at each stop. The data from these projections are used to reconstruct transverse images with a standard ''filtered back-projection'' algorithm, identical to that used in transmission CT. Because the scintillation camera acquires two-dimensional images, a simple 360 degree rotation around the patient results in the acquisition of data for a number of contiguous transverse slices. These slices, once reconstructed, can be ''stacked'' in computer memory, and orthogonal coronal and sagittal slices produced. Additionally, reorienting algorithms allow the generation of slices that are oblique to the long axis of the body

  19. Image reconstruction from projections and its application in emission computer tomography

    International Nuclear Information System (INIS)

    Kuba, Attila; Csernay, Laszlo

    1989-01-01

    Computer tomography is an imaging technique for producing cross sectional images by reconstruction from projections. Its two main branches are called transmission and emission computer tomography, TCT and ECT, resp. After an overview of the theory and practice of TCT and ECT, the first Hungarian ECT type MB 9300 SPECT consisting of a gamma camera and Ketronic Medax N computer is described, and its applications to radiological patient observations are discussed briefly. (R.P.) 28 refs.; 4 figs

  20. Simulation on a limited angle beam gamma ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jong Bum; Jung, Sung Hee; Moon, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Limited angle beam tomography was introduced in the medical field more than two decades ago, where it was mainly used for cardiovascular diagnostics. Later, it was also used to trace multiphase flows. In these studies, the detection systems were fixed and a scanning electron beam was rapidly swept across an xray target using deflection coils. Thus very fast scanning was possible in these studies, but their geometry resulted in a heavy and bulky system because of a complex control system and vacuum tube. Because of its heavy hardware, limited angle beam tomography has remained as indoor equipment. If the source section is replaced by a gamma ray source, limited angle beam tomography will have a very light source device. In addition, limited angle beam tomography with a gamma ray source can be designed using an open type portable gantry because it does not need a vacuum guide for an electron beam. There is a lot of need for a portable tomographic system but so far no definitive solution has been created. The inspection of industrial on-line pipes, wood telephone poles, and cultural assets are some application areas. This study introduces limited angle beam gamma ray tomography, its simulation, and image reconstruction results. Image reconstruction was performed on the virtual experimental data from a Monte Carlo simulation. Image reconstruction algorithms that are known to be useful for limited angle data were applied and their results compared

  1. Positron emission tomography in the diagnosis and staging of lung cancer

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Højgaard, L

    2001-01-01

    positron emission tomography (PET) and gamma-camera PET in the diagnostic investigation of non-small-cell lung cancer (NSCLC). A systematic literature search was carried out in the MEDLINE and EMBASE databases and the Cochrane Controlled Trials Register. We identified 55 original works on the diagnostic...

  2. Egret observations of the extragalactic gamma-ray emission

    DEFF Research Database (Denmark)

    Sreekumar, P.; Bertsch, D.L.; Dingus, B.L.

    1998-01-01

    The all-sky survey in high-energy gamma rays (E > 30 MeV) carried out by EGRET aboard the Compton Gamma Ray Observatory provides a unique opportunity to examine in detail the diffuse gamma-ray emission. The observed diffuse emission has a Galactic component arising from cosmic-ray interactions wi...

  3. Simulation Study of Single Photon Emission Computed Tomography for Industrial Applications

    International Nuclear Information System (INIS)

    Roy, Tushar; Sarkar, P. S.; Sinha, Amar

    2008-01-01

    SPECT (Single Photon Emission Computed Tomography) provides for an invaluable non-invasive technique for the characterization and activity distribution of the gamma-emitting source. For many applications of radioisotopes for medical and industrial application, not only the positional information of the distribution of radioisotopes is needed but also its strength. The well-established X-ray radiography or transmission tomography techniques do not yield sufficient quantitative information about these objects. Emission tomography is one of the important methods for such characterization. Application of parallel beam, fan beam and 3D cone beam emission tomography methods have been discussed in this paper. Simulation studies to test these algorithms have been carried out to validate the technique.

  4. Positron Emission Tomography: Its 65 years

    International Nuclear Information System (INIS)

    Del Guerra, A.; Belcari, N.; Bisogni, M.

    2016-01-01

    Positron Emission Tomography (PET) is a well-established imaging technique for in vivo molecular imaging. In this review after a brief history of PET there are presented its physical principles and the technology that has been developed for bringing PET from a bench experiment to a clinical indispensable instrument. The limitations and performance of the PET tomographs are discussed, both as for the hardware and software aspects. The status of art of clinical, preclinical and hybrid scanners (i.e., PET/CT and PET/MR) is reported. Finally the actual trend and the recent and future technological developments are fully illustrated.

  5. Methods and instrumentation for positron emission tomography

    International Nuclear Information System (INIS)

    Mandelkern, M.A.; Phelps, M.E.

    1988-01-01

    This paper reports on positron emission tomography (PET), a technique for the noninvasive measurement of local tissue concentrations of injected radioactive tracers. Tracer kinetics techniques can be applied to this information to quantify physiologic function in human tissue. In the tracer method, a pharmaceutical is labeled by a radioactive atom. When introduced into the subject that molecule follows a physiologic pathway. The space- and time-dependent distribution of the radionuclide is obtained via an imaging technique. If the radiopharmaceutical is sufficiently analogous to a natural substrate or other substance of interest, a quantitative image can be translated into a physiologic measurement

  6. Features and applications of positron emission tomography

    International Nuclear Information System (INIS)

    Fan Mingwu

    1997-01-01

    Positron emission tomography, the so-called world's smartest camera, is based on a NaI or BGO detector and imaging of positron-emitting radioisotopes which are introduced as a tracer into the regional tissue or organ of interest. With the aid of a computer visual images of a series of these distributions can be built into a picture of the functional status of the tissue or organ being imaged. This highly accurate imaging technique is already widely used for clinical diagnostics heart disease, brain disorder, tumors and so on

  7. Contribution of positron emission tomography in neurology

    International Nuclear Information System (INIS)

    Salmon, E.; Franck, G.

    1992-01-01

    Positron Emission Tomography (PET) is a scanner technique using tracers labelled with shortlived radioisotopes which allows to study and quantify human metabolic processes or drug pharmacology in vivo. The technique is first applied in physiological studies. Sleep, normal brain metabolism or cerebral activations have been studied. The pharmacological approach concerns both drug distribution in the human brain and blood flow or metabolic variations under treatment. Main neurological applications in pathology are cerebrovascular disorders, diseases leading to dementia, epilepsy, movement disorders, and brain tumors. In each field of application, PET gives unique and frequently early informations. It nicely combines both dynamic informations and measurement precision. (author)

  8. Electrocardiographic gating in positron emission computed tomography

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Wisenberg, G.; Schelbert, H.R.; Kuhl, D.E.

    1979-01-01

    Electrocardiographic (ECG) synchronized multiple gated data acquisition was employed with positron emission computed tomography (ECT) to obtain images of myocardial blood pool and myocardium. The feasibility and requirements of multiple gated data acquisition in positron ECT were investigated for 13NH3, ( 18 F)-2-fluoro-2-D-deoxyglucose, and ( 11 C)-carboxyhemoglobin. Examples are shown in which image detail is enhanced and image interpretation is facilitated when ECG gating is employed in the data collection. Analysis of count rate data from a series of volunteers indicates that multiple, statistically adequate images can be obtained under a multiple gated data collection format without an increase in administered dose

  9. Positron emission tomography/computed tomography imaging and rheumatoid arthritis.

    Science.gov (United States)

    Wang, Shi-Cun; Xie, Qiang; Lv, Wei-Fu

    2014-03-01

    Rheumatoid arthritis (RA) is a phenotypically heterogeneous, chronic, destructive inflammatory disease of the synovial joints. A number of imaging tools are currently available for evaluation of inflammatory conditions. By targeting the upgraded glucose uptake of infiltrating granulocytes and tissue macrophages, positron emission tomography/computed tomography with fluorine-18 fluorodeoxyglucose ((18) F-FDG PET/CT) is available to delineate inflammation with high sensitivity. Recently, several studies have indicated that FDG uptake in affected joints reflects the disease activity of RA. In addition, usage of FDG PET for the sensitive detection and monitoring of the response to treatment has been reported. Combined FDG PET/CT enables the detailed assessment of disease in large joints throughout the whole body. These unique capabilities of FDG PET/CT imaging are also able to detect RA-complicated diseases. Therefore, PET/CT has become an excellent ancillary tool to assess disease activity and prognosis in RA. © 2014 Asia Pacific League of Associations for Rheumatology and Wiley Publishing Asia Pty Ltd.

  10. Therapy response evaluation with positron emission tomography-computed tomography.

    Science.gov (United States)

    Segall, George M

    2010-12-01

    Positron emission tomography-computed tomography with F-18-fluorodeoxyglucose is widely used for evaluation of therapy response in patients with solid tumors but has not been as readily adopted in clinical trials because of the variability of acquisition and processing protocols and the absence of universal response criteria. Criteria proposed for clinical trials are difficult to apply in clinical practice, and gestalt impression is probably accurate in individual patients, especially with respect to the presence of progressive disease and complete response. Semiquantitative methods of determining tissue glucose metabolism, such as standard uptake value, can be a useful descriptor for levels of tissue glucose metabolism and changes in response to therapy if technical quality control measures are carefully maintained. The terms partial response, complete response, and progressive disease are best used in clinical trials in which the terms have specific meanings and precise definitions. In clinical practice, it may be better to use descriptive terminology agreed upon by imaging physicians and clinicians in their own practice. Copyright © 2010. Published by Elsevier Inc.

  11. Classification of JET Neutron and Gamma Emissivity Profiles

    Science.gov (United States)

    Craciunescu, T.; Murari, A.; Kiptily, V.; Vega, J.; Contributors, JET

    2016-05-01

    In thermonuclear plasmas, emission tomography uses integrated measurements along lines of sight (LOS) to determine the two-dimensional (2-D) spatial distribution of the volume emission intensity. Due to the availability of only a limited number views and to the coarse sampling of the LOS, the tomographic inversion is a limited data set problem. Several techniques have been developed for tomographic reconstruction of the 2-D gamma and neutron emissivity on JET. In specific experimental conditions the availability of LOSs is restricted to a single view. In this case an explicit reconstruction of the emissivity profile is no longer possible. However, machine learning classification methods can be used in order to derive the type of the distribution. In the present approach the classification is developed using the theory of belief functions which provide the support to fuse the results of independent clustering and supervised classification. The method allows to represent the uncertainty of the results provided by different independent techniques, to combine them and to manage possible conflicts.

  12. Physical and technical basis of positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Bauer, R.

    1994-01-01

    Positron emission tomography utilizes the annihilation of positrons, generating pairs of gamma quanta which are emitted in opposing directions. 'Electronic collimation' is performed by coincident detection of both quanta. Thus, there is no need for mechanical collimators and no limiting connection between sensitivity and spatial resolution. Transversal tomograms are reconstructed from the projection data by means of highly sophisticated data processing. The half life of the most positron emitters used in medical applications is short and of the order of some minutes. Therefore, many positron emitters have to be produced on-side by means of a cyclotron. PET is superior to SPECT with respect to physical and technical aspects, but the high costs of PET limit its wide-spread use up to now. (orig.) [de

  13. Cardiological applications of positron emission tomography

    International Nuclear Information System (INIS)

    Schelbert, H.; Czernin, J.

    1994-01-01

    Positron emission tomography (PET) expands the diagnostic possibilities of nuclear medicine techniques for the diagnosis of coronary artery disease and, especially, for the identification of myocardial viability. The presence of coronary artery disease can be detected by evaluation of myocardial blood flow at rest and during pharmacologically induced hyperemia with a sensitivity of 84 to 98% and a specificity of 78 to 100% according to recent studies. Comparative investigations in the same patients have demonstrated a significant gain in the diagnostic accuracy of PET as compared with single photon emission computed tomography (SPECT). PET has influenced even more profoundly the identification of myocardial viability. Measured against the functional outcome of regional contractile function after successful revascularization, an increase of glucose utilization relative to regional myocardial blood flow is 77 to 85% accurate in identifying reversibly injured myocardium. Conversely, PET is 78 to 92% accurate in identifying myocardium as irreversibly injured when pre-operative glucose uptake was reduced or absent. Recent studies have indicated that it is possible to predict to some extent post-revascularization improvement in left ventricular function as well as in congestive heart failure related symptoms in patients with ischemic cardiomyopathy. Furthermore, PET can identify patients with an increased risk of mortality and morbidity as a result of ischemic heart disease and, thus, stratify patients to the most appropriate and cost-effective therapeutic approach. (authors)

  14. Positron emission tomography of the lung

    International Nuclear Information System (INIS)

    Wollmer, P.

    1984-01-01

    Positron emission tomography enables the distribution of positron emitting isotopes to be imaged in a transverse plane through the body and the regional concentration of the isotope to be measured quantitatively. This thesis reports some applications of positron emission tomography to studies of pulmonary pathophysiology. Measurements in lung phantoms showed that regional lung density could be measured from a transmission tomogram obtained with an external source of positron emitting isotope. The regional, fractional blood volume was measured after labelling the blood with carbon-11-monoxide. Regional extravascular lung density (lung tissue and interstitial water per unit thoracic volume) was obtained by subtracting fractional blood volume from lung density. Measurements in normal subjects revealed large regional variations in lung density and fractional blood volume in the supine posture. Extravascular lung density showed a more uniform distribution. The technique has been used to study patients with chronic interstitial pulmonary oedema, pulmonary sarcoidosis and fibrosis, pulmonary arterial hypertension and patients with intracardiac, left-to-right shunt. Tomographic measurements of pulmonary tissue concentration of radionuclides are difficult, since corrections for the blood content and the inflation of the lung must be applied. A simultaneous measurement of lung density and fractional blood volume allows such corrections to be made and the extravascular tracer concentration to be calculated. This has been applied to measurements of the tissue penetration of carbon-11-labelled erythromycin in patients with lobar pneumonia. (author)

  15. RELIABILITY OF POSITRON EMISSION TOMOGRAPHY-COMPUTED TOMOGRAPHY IN EVALUATION OF TESTICULAR CARCINOMA PATIENTS.

    Science.gov (United States)

    Nikoletić, Katarina; Mihailović, Jasna; Matovina, Emil; Žeravica, Radmila; Srbovan, Dolores

    2015-01-01

    The study was aimed at assessing the reliability of 18F-fluorodeoxyglucose positron emission tomography-computed tomography scan in evaluation of testicular carcinoma patients. The study sample consisted of 26 scans performed in 23 patients with testicular carcinoma. According to the pathohistological finding, 14 patients had seminomas, 7 had nonseminomas and 2 patients had a mixed histological type. In 17 patients, the initial treatment was orchiectomy+chemotherapy, 2 patients had orchiectomy+chemotherapy+retroperitoneal lymph node dissection, 3 patients had orchiectomy only and one patient was treated with chemotherapy only. Abnormal computed tomography was the main cause for the oncologist to refer the patient to positron emission tomography-computed tomography scan (in 19 scans), magnetic resonance imaging abnormalities in 1 scan, high level oftumor markers in 3 and 3 scans were perforned for follow-up. Positron emission tomography-computed tomography imaging results were compared with histological results, other imaging modalities or the clinical follow-up of the patients. Positron emission tomography-computed tomography scans were positive in 6 and negative in 20 patients. In two patients, positron emission tomography-computed tomography was false positive. There were 20 negative positron emission omography-computed tomography scans perforned in 18 patients, one patient was lost for data analysis. Clinically stable disease was confirmed in 18 follow-up scans performed in 16 patients. The values of sensitivty, specificity, accuracy, and positive- and negative predictive value were 60%, 95%, 75%, 88% and 90.5%, respectively. A hgh negative predictive value obtained in our study (90.5%) suggests that there is a small possibility for a patient to have future relapse after normal positron emission tomography-computed tomography study. However, since the sensitivity and positive predictive value of the study ire rather low, there are limitations of positive

  16. F-18-fluorodeoxyglucose-positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Joerg, L.; Langsteger, W.

    2002-01-01

    Whole-body positron emission tomography (PET) with the radiolabeled glucose analog F-18-fluorodeoxyglucose (F-18-FDG) is a sensitive diagnostic tool that images tumors based on increased uptake of glucose. Several recent publications have shown that F-18-fluorodeoxyglucose-positron emission tomography is more sensitive than computed-tomography (CT) in detecting colorectal cancer. In patients with increasing CEA (carcinoembryonic antigen) and no evidence of recurrent disease on CT F-18-fluorodeoxyglucose-positron emission tomography often detects recurrent cancer. In all, patient management seems to be changed in about 25 % of patients who undergo F-18-fluorodeoxyglucose-positron emission tomography in addition to standard staging procedure. Limited reports to date on both chemotherapy and radiotherapy support the role of F-18-fluorodeoxyglucose-positron emission tomography in assessing treatment response. Also regarding preoperative staging of primary colorectal cancer the literature is very limited. (author)

  17. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

    Science.gov (United States)

    Kinahan, Paul E; Hasegawa, Bruce H; Beyer, Thomas

    2003-07-01

    A synergy of positron emission tomography (PET)/computed tomography (CT) scanners is the use of the CT data for x-ray-based attenuation correction of the PET emission data. Current methods of measuring transmission use positron sources, gamma-ray sources, or x-ray sources. Each of the types of transmission scans involves different trade-offs of noise versus bias, with positron transmission scans having the highest noise but lowest bias, whereas x-ray scans have negligible noise but the potential for increased quantitative errors. The use of x-ray-based attenuation correction, however, has other advantages, including a lack of bias introduced from post-injection transmission scanning, which is an important practical consideration for clinical scanners, as well as reduced scan times. The sensitivity of x-ray-based attenuation correction to artifacts and quantitative errors depends on the method of translating the CT image from the effective x-ray energy of approximately 70 keV to attenuation coefficients at the PET energy of 511 keV. These translation methods are usually based on segmentation and/or scaling techniques. Errors in the PET emission image arise from positional mismatches caused by patient motion or respiration differences between the PET and CT scans; incorrect calculation of attenuation coefficients for CT contrast agents or metallic implants; or keeping the patient's arms in the field of view, which leads to truncation and/or beam-hardening (or x-ray scatter) artifacts. Proper interpretation of PET emission images corrected for attenuation by using the CT image relies on an understanding of the potential artifacts. In cases where an artifact or bias is suspected, careful inspection of all three available images (CT and PET emission with and without attenuation correction) is recommended. Copyright 2003 Elsevier Inc. All rights reserved.

  18. OBSERVATION OF CORRELATED OPTICAL AND GAMMA EMISSIONS FROM GRB 081126

    International Nuclear Information System (INIS)

    Klotz, A.; Boer, M.; Gendre, B.; Atteia, J. L.; Coward, D. M.; Imerito, A. C.

    2009-01-01

    We present an analysis of time-resolved optical emissions observed from the gamma-ray burst GRB 081126 during the prompt phase. The analysis employed time-resolved photometry using optical data obtained by the TAROT telescope, using BAT data from the Swift spacecraft, and time-resolved spectroscopy at high energies from the GBM instrument onboard the Fermi spacecraft. The optical emission of GRB 081126 is found to be compatible with the second gamma emission pulse shifted by a positive time lag of 8.4 ± 3.9 s. This is the first well-resolved observation of a time lag between optical and gamma emissions during a gamma-ray burst. Our observations could potentially provide new constraints on the fireball model for gamma-ray burst early emissions. Furthermore, observations of time lags between optical and gamma ray photons provides an exciting opportunity to constrain quantum gravity theories.

  19. A Correlated Optical and Gamma Emission from GRB 081126A

    International Nuclear Information System (INIS)

    Gendre, B.; Klotz, A.; Atteia, J. L.; Boeer, M.; Coward, D. M.; Imerito, A. C.

    2010-01-01

    We present an analysis of time-resolved optical emissions observed from the gamma-ray burst GRB 081126 during the prompt phase. The analysis employed time-resolved photometry using optical data obtained by the TAROT telescope, BAT data from the Swift spacecraft and time-resolved spectroscopy at high energies from the GBM instrument onboard the Fermi spacecraft. The optical emission of GRB 081126 is found to be compatible with the second gamma emission pulse shifted by a positive time-lag of 8.4±3.9 sec. This is the first well resolved observation of a time lag between optical and gamma emissions during a gamma-ray burst. Our observations could potentially provide new constraints on the fireball model for gamma ray burst early emissions. Furthermore, observations of time-lags between optical and gamma ray photons provides an exciting opportunity to constrain quantum gravity theories.

  20. Single-photon emission tomography and cerebral blood flow

    International Nuclear Information System (INIS)

    Celsis, P.; Chan, M.; Marc-Vergnes, J.P.; Sveinsdottir, E.; Goldman, T.G.; Henriksen, L.; Paulson, O.B.; Stokely, E.M.; Lassen, N.A.

    1982-01-01

    This paper illustrates the capabilities of single-photon emission tomography in imaging local cerebral blood flows in man. The results purport the conclusion that a fairly good improvement has been achieved when compared to stationary detectors and that single-photon emission tomography is a well-suited tool for studying cerebral hemodynamics, especially within the framework of clinical studies [fr

  1. Positron emission tomography in drug development

    International Nuclear Information System (INIS)

    Rubin, R. H.; Fischman, A. J.

    1997-01-01

    There are four kinds of measurements that can be carried out with positron emission tomography (PET) that can contribute significantly to the process of drug development: pharmacodynamic measurement of tissue metabolism influenced by a given drug; precise measurements of tissue blood flow; tissue pharmacokinetics of a given drug following administration of a particular dose; and the temporal course of ligand-receptor interaction. One or more of these measurements can greatly improve the decision making involved in determining the appropriate dose of a drug, the clinical situations in which a drug might be useful, and the linkage of pharmacokinetics with pharmacodynamics, which is at the heart of effective drug development. The greater the potential of a particular compound as a therapeutic agent, the greater the potential for PET to contribute to the drug development process

  2. Applications of positron emission tomography to psychiatry

    International Nuclear Information System (INIS)

    Volkow, N.D.; Brodie, J.D.; Gomez-mont, F.

    1985-01-01

    The brain's inaccessibility has hampered investigation of the metabolic changes underlying the behavioral and psychological symptoms of psychiatric patients. Using positron emission transaxial tomography (PET) to study the functioning human brain opens the possibility of directly investigating the patterns of activity associated with mental illness. A major focus of present-day research in psychiatry has been to identify etiological agents that fit a medical model of psychiatric illness. Experiments seeking pathophysiological indices that would permit objective classification of psychiatric illnesses have failed to reveal consistent abnormalities. The lack of consistency is explained in part by research designs that deal with the brain as if it were a homogeneous organ. PET offers a unique technique for monitoring the regional biochemical activity that is associated with the different ''brain states'' and ''brain traits'' of normal subjects and psychiatric patients

  3. Motion correction in thoracic positron emission tomography

    CERN Document Server

    Gigengack, Fabian; Dawood, Mohammad; Schäfers, Klaus P

    2015-01-01

    Respiratory and cardiac motion leads to image degradation in Positron Emission Tomography (PET), which impairs quantification. In this book, the authors present approaches to motion estimation and motion correction in thoracic PET. The approaches for motion estimation are based on dual gating and mass-preserving image registration (VAMPIRE) and mass-preserving optical flow (MPOF). With mass-preservation, image intensity modulations caused by highly non-rigid cardiac motion are accounted for. Within the image registration framework different data terms, different variants of regularization and parametric and non-parametric motion models are examined. Within the optical flow framework, different data terms and further non-quadratic penalization are also discussed. The approaches for motion correction particularly focus on pipelines in dual gated PET. A quantitative evaluation of the proposed approaches is performed on software phantom data with accompanied ground-truth motion information. Further, clinical appl...

  4. Positron emission tomography and basal ganglia functions

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Motohiro; Otsuka, Makoto; Taniwaki, Koukyo; Hosokawa, Shinichi; Kuwabara, Yasuo; Ichiya, Yuichi [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1990-05-01

    With the advent of positron emission tomography (PET), studies on the human brain function and pathophysiology of brain damage have been extremely progressed. It is well-known that the basal ganglia plays an important role as one of the central nervous system involved in exercise regulation. More recently, the potential involvement of the basal ganglia in psychological processes, such as cognitive function, has been pointed out, receiving much attention. In spite of such a lot of studies, however, basal ganglia function remains unclear. This paper describes the relationships between PET findings and basal ganglia function. PET findings are discussed in relation to brain energy metabolism and striatal dopamine function. Pathophysiology of the basal ganglia are described in terms of the following diseases: Parkinson's disease, Parkinson's syndrome, progressive supranuclear palsy, Huntington's disease, and dystonia. Physiological backgrounds of the basal ganglia for PET images are also referred to. (N.K.) 75 refs.

  5. Positron emission tomography and basal ganglia functions

    International Nuclear Information System (INIS)

    Kato, Motohiro; Otsuka, Makoto; Taniwaki, Koukyo; Hosokawa, Shinichi; Kuwabara, Yasuo; Ichiya, Yuichi

    1990-01-01

    With the advent of positron emission tomography (PET), studies on the human brain function and pathophysiology of brain damage have been extremely progressed. It is well-known that the basal ganglia plays an important role as one of the central nervous system involved in exercise regulation. More recently, the potential involvement of the basal ganglia in psychological processes, such as cognitive function, has been pointed out, receiving much attention. In spite of such a lot of studies, however, basal ganglia function remains unclear. This paper describes the relationships between PET findings and basal ganglia function. PET findings are discussed in relation to brain energy metabolism and striatal dopamine function. Pathophysiology of the basal ganglia are described in terms of the following diseases: Parkinson's disease, Parkinson's syndrome, progressive supranuclear palsy, Huntington's disease, and dystonia. Physiological backgrounds of the basal ganglia for PET images are also referred to. (N.K.) 75 refs

  6. Partial Volume Effects correction in emission tomography

    International Nuclear Information System (INIS)

    Le Pogam, Adrien

    2010-01-01

    Partial Volume Effects (PVE) designates the blur commonly found in nuclear medicine images and this PhD work is dedicated to their correction with the objectives of qualitative and quantitative improvement of such images. PVE arise from the limited spatial resolution of functional imaging with either Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT). They can be defined as a signal loss in tissues of size similar to the Full Width at Half Maximum (FWHM) of the PSF of the imaging device. In addition, PVE induce activity cross contamination between adjacent structures with different tracer uptakes. This can lead to under or over estimation of the real activity of such analyzed regions. Various methodologies currently exist to compensate or even correct for PVE and they may be classified depending on their place in the processing chain: either before, during or after the image reconstruction process, as well as their dependency on co-registered anatomical images with higher spatial resolution, for instance Computed Tomography (CT) or Magnetic Resonance Imaging (MRI). The voxel-based and post-reconstruction approach was chosen for this work to avoid regions of interest definition and dependency on proprietary reconstruction developed by each manufacturer, in order to improve the PVE correction. Two different contributions were carried out in this work: the first one is based on a multi-resolution methodology in the wavelet domain using the higher resolution details of a co-registered anatomical image associated to the functional dataset to correct. The second one is the improvement of iterative deconvolution based methodologies by using tools such as directional wavelets and curvelets extensions. These various developed approaches were applied and validated using synthetic, simulated and clinical images, for instance with neurology and oncology applications in mind. Finally, as currently available PET/CT scanners incorporate more

  7. Gravitational Waves versus X and Gamma Ray Emission in a Short Gamma-Ray Burst

    OpenAIRE

    Oliveira, F. G.; Rueda, Jorge A.; Ruffini, Remo

    2012-01-01

    The recent progress in the understanding the physical nature of neutron star equilibrium configurations and the first observational evidence of a genuinely short gamma-ray burst, GRB 090227B, allows to give an estimate of the gravitational waves versus the X and Gamma-ray emission in a short gamma-ray burst.

  8. High-energy gamma-ray emission in compact binaries

    International Nuclear Information System (INIS)

    Cerutti, Benoit

    2010-01-01

    Four gamma-ray sources have been associated with binary systems in our Galaxy: the micro-quasar Cygnus X-3 and the gamma-ray binaries LS I +61 degrees 303, LS 5039 and PSR B1259-63. These systems are composed of a massive companion star and a compact object of unknown nature, except in PSR B1259-63 where there is a young pulsar. I propose a comprehensive theoretical model for the high-energy gamma-ray emission and variability in gamma-ray emitting binaries. In this model, the high-energy radiation is produced by inverse Compton scattering of stellar photons on ultra-relativistic electron-positron pairs injected by a young pulsar in gamma-ray binaries and in a relativistic jet in micro-quasars. Considering anisotropic inverse Compton scattering, pair production and pair cascade emission, the TeV gamma-ray emission is well explained in LS 5039. Nevertheless, this model cannot account for the gamma-ray emission in LS I +61 degrees 303 and PSR B1259-63. Other processes should dominate in these complex systems. In Cygnus X-3, the gamma-ray radiation is convincingly reproduced by Doppler-boosted Compton emission of pairs in a relativistic jet. Gamma-ray binaries and micro-quasars provide a novel environment for the study of pulsar winds and relativistic jets at very small spatial scales. (author)

  9. Applications of multi-pinhole gamma camera collimation to tomography and image enhancement

    Science.gov (United States)

    Simpson, D. R.

    1981-06-01

    Multi-pinhole gamma camera collimation was introduced in the field of emission tomography. This collimation process simultaneously produces several images covering a limited angular range, which may then be recombined to obtain tomographic slices of the object imaged. A possible method for improving the images obtained by this technique by combining two multi-pinhole views taken 90 deg apart was investigated. Collimators were designed and built both for tomography and imaging tablet disintegration, and computer programs were written to reconstruct the images by simple backprojection and by filtered backprojection. The use of multi-pinhole collimators to image the disintegration of tablets in vivo was clearly demonstrated. Phantom tests done in vitro were capable of imaging defects as small as 5 sq mm, while images made with real tablets both in vitro and in vivo readily showed the onset and progress of the tablet disintegration.

  10. Gamma-ray emission profile measurements during JET ICRH discharges

    Energy Technology Data Exchange (ETDEWEB)

    Jarvis, O N; Marcus, F B; Sadler, G; Van Belle, P [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Howarth, P J.A. [Birmingham Univ. (United Kingdom); Adams, J M; Bond, D S [UKAEA Harwell Lab. (United Kingdom). Energy Technology Div.

    1994-07-01

    Gamma-ray emission from plasma-impurity reactions caused by minority ICRH accelerating fuel ions to MeV energies has been measured using the JET neutron profile monitor. A successful data analysis technique has been used to isolate the RF-induced gamma-ray emission that was detected, enabling profiles of gamma-ray emission to be obtained. The 2-d gamma-ray emission profiles show that virtually all the radiation originates from the low field side of the RF resonance layer, as expected from RF-induced pitch angle diffusion. The emission profiles indicate the presence of a small population of resonant {sup 3}He ions that possess orbits lying near the passing-trapped boundary. 6 refs., 4 figs.

  11. The Positron Emission Tomography. A diagnostic technique

    International Nuclear Information System (INIS)

    Salvadori, P.

    2001-01-01

    Positron Emission Tomography (PET) is a new imaging modality, which is able to assess non-invasively the biochemical mechanisms, underlying physiological and pathophysiological processes in vivo in humans. The technique relies on the administration of radioactive tracers labeled with short-lived positron emitters, which need to be produced on site via a particle accelerator (cyclotron). Radionuclides are produced upon request and formulated into biologically active organic molecules having precise pharmacokinetics and specificity. The radiotracer can be detected by the PET scanner and represented as tomographic sections (images of body sections) showing its regional distribution and concentration. This makes it possible to address clinical questions concerning occurrence and evolution of many diseases as well as their response to therapy. The ability to image (measure) biological processes and not only anatomy enables PET to explore diseases in the very early stage, including those diseases which are not related to modifications of organ structure (e.g. psychiatric diseases, metabolic disorders, biochemical disfunction). PET plays a major role, in conjunction with the other imaging modalities, to improve diagnosis capabilities and disease mechanism understanding [it

  12. A continuation method for emission tomography

    International Nuclear Information System (INIS)

    Lee, M.; Zubal, I.G.

    1993-01-01

    One approach to improved reconstructions in emission tomography has been the incorporation of additional source information via Gibbs priors that assume a source f that is piecewise smooth. A natural Gibbs prior for expressing such constraints is an energy function E(f,l) defined on binary valued line processes l as well as f. MAP estimation leads to the difficult problem of minimizing a mixed (continuous and binary) variable objective function. Previous approaches have used Gibbs 'potential' functions, φ(f v ) and φ(f h ), defined solely on spatial derivatives, f v and f h , of the source. These φ functions implicitly incorporate line processes, but only in an approximate manner. The correct φ function, φ * , consistent with the use of line processes, leads to difficult minimization problems. In this work, the authors present a method wherein the correct φ * function is approached through a sequence of smooth φ functions. This is the essence of a continuation method in which the minimum of the energy function corresponding to one member of the φ function sequence is used as an initial condition for the minimization of the next, less approximate, stage. The continuation method is implemented using a GEM-ICM procedure. Simulation results show improvement using the continuation method relative to using φ * alone, and to conventional EM reconstructions

  13. Amorphous silicon detectors in positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Conti, M. (Istituto Nazionale di Fisica Nucleare, Pisa (Italy) Lawrence Berkeley Lab., CA (USA)); Perez-Mendez, V. (Lawrence Berkeley Lab., CA (USA))

    1989-12-01

    The physics of the detection process is studied and the performances of different Positron Emission Tomography (PET) system are evaluated by theoretical calculation and/or Monte Carlo Simulation (using the EGS code) in this paper, whose table of contents can be summarized as follows: a brief introduction to amorphous silicon detectors and some useful equation is presented; a Tantalum/Amorphous Silicon PET project is studied and the efficiency of the systems is studied by Monte Carlo Simulation; two similar CsI/Amorphous Silicon PET projects are presented and their efficiency and spatial resolution are studied by Monte Carlo Simulation, light yield and time characteristics of the scintillation light are discussed for different scintillators; some experimental result on light yield measurements are presented; a Xenon/Amorphous Silicon PET is presented, the physical mechanism of scintillation in Xenon is explained, a theoretical estimation of total light yield in Xenon and the resulting efficiency is discussed altogether with some consideration of the time resolution of the system; the amorphous silicon integrated electronics is presented, total noise and time resolution are evaluated in each of our applications; the merit parameters {epsilon}{sup 2}{tau}'s are evaluated and compared with other PET systems and conclusions are drawn; and a complete reference list for Xenon scintillation light physics and its applications is presented altogether with the listing of the developed simulation programs.

  14. Functional cardiac imaging: positron emission tomography

    International Nuclear Information System (INIS)

    Mullani, N.A.; Gould, K.L.

    1984-01-01

    Dynamic cardiovascular imaging plays a vital role in the diagnosis and treatment of cardiac disease by providing information about the function of the heart. During the past 30 years, cardiovascular imaging has evolved from the simple chest x-ray and fluoroscopy to such sophisticated techniques as invasive cardiac angiography and cinearteriography and, more recently, to noninvasive cardiac CT scanning, nuclear magnetic resonance, and positron emission tomography, which reflect more complex physiologic functions. As research tools, CT, NMR, and PET provide quantitative information on global as well as regional ventricular function, coronary artery stenosis, myocardial perfusion, glucose and fatty acid metabolism, or oxygen utilization, with little discomfort or risk to the patient. As imaging modalities become more sophisticated and more oriented toward clinical application, the prospect of routinely obtaining such functional information about the heart is becoming realistic. However, these advances are double-edged in that the interpretation of functional data is more complex than that of the anatomic imaging familiar to most physicians. They will require an enhanced understanding of the physiologic and biochemical processes, as well as of the instrumentation and techniques for analyzing the data. Of the new imaging modalities that provide functional information about the heart, PET is the most useful because it quantitates the regional distribution of radionuclides in vivo. Clinical applications, interpretation of data, and the impact of PET on our understanding of cardiac pathophysiology are discussed. 5 figures

  15. Amorphous silicon detectors in positron emission tomography

    International Nuclear Information System (INIS)

    Conti, M.; Perez-Mendez, V.

    1989-12-01

    The physics of the detection process is studied and the performances of different Positron Emission Tomography (PET) system are evaluated by theoretical calculation and/or Monte Carlo Simulation (using the EGS code) in this paper, whose table of contents can be summarized as follows: a brief introduction to amorphous silicon detectors and some useful equation is presented; a Tantalum/Amorphous Silicon PET project is studied and the efficiency of the systems is studied by Monte Carlo Simulation; two similar CsI/Amorphous Silicon PET projects are presented and their efficiency and spatial resolution are studied by Monte Carlo Simulation, light yield and time characteristics of the scintillation light are discussed for different scintillators; some experimental result on light yield measurements are presented; a Xenon/Amorphous Silicon PET is presented, the physical mechanism of scintillation in Xenon is explained, a theoretical estimation of total light yield in Xenon and the resulting efficiency is discussed altogether with some consideration of the time resolution of the system; the amorphous silicon integrated electronics is presented, total noise and time resolution are evaluated in each of our applications; the merit parameters ε 2 τ's are evaluated and compared with other PET systems and conclusions are drawn; and a complete reference list for Xenon scintillation light physics and its applications is presented altogether with the listing of the developed simulation programs

  16. Positron emission tomography (PET) in psychiatry

    International Nuclear Information System (INIS)

    Buchsbaum, M.S.

    1984-01-01

    In the past the approach to the brain has been necessarily indirect, employing peripheral fluids to assess central and regional neurochemical processes. Blood, urine, skin and muscle biopsy, and cerebrospinal fluid are valuable reflectors of the neurochemical and neuropharmacological activity of the brain, but are removed in time and place from disordered thought processes and diluted by the products of both functional and dysfunctional brain systems. Biopsy studies have helped in studying the functional disorders of organs like the liver, but they are destructive to the brain and less useful because unlike these organs, the brain has a regional variation in its chemistry. The experimental insights from animal studies focusing on the pharmacology of individual cell groups - in striatum or locus coeruleus, for example - cannot easily or unambigiously be applied to clinical populations. Positron emission tomography (PET) is a versatile approach utilizing the mathematics of x-ray transmission scanning (CT scanning) to produce slice images of radioisotope distribution. PET makes possible a wide range of metabolic studies. Positron emitters such as carbon-11 or fluorine-18 can be used to label glucose, amino acids, drugs, neurotransmitter precursors, and many other molecules and examine their distribution and fate in discrete cell groups

  17. Gamma-ray emission profile measurements during JET ICRH discharges

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, P.J.A. [Birmingham Univ. (United Kingdom); Adams, J.M.; Bond, D.S.; Watkins, N. [AEA Technology, Harwell (United Kingdom); Jarvis, O.N.; Marcus, F.B.; Sadler, G.; Belle, P. van [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

    1994-12-31

    Ion Cyclotron Resonant Heating (ICRH) that is tuned to minority fuel ions can induce an energy diffusion of the heated species and create high energy tail temperatures of {approx} 1 MeV. The most energetic of these accelerated minority ions can undergo nuclear reactions with impurity Be and C that produces {gamma}-ray emission from the decay of the excited product nuclei. This RF-induced {gamma}-ray emission has been recorded using the JET neutron emission profile diagnostic which is capable of distinguishing neutrons and {gamma}-rays. Appropriate data processing has enabled the RF-induced {gamma}-ray emission signals to be isolated from the {gamma}-ray emission signals associated with neutron interactions in the material surrounding the profile monitor. The 2-d {gamma}-ray emission profiles show that virtually all the radiation originates from the low field side of the RF resonance layer, as expected from RF-induced pitch angle diffusion. The emission profiles indicate the presence of a small population of resonant {sup 3}He ions that possess orbits lying near the passing-trapped boundary. (author) 6 refs., 4 figs.

  18. Positron emission tomography for the assessment of myocardial viability

    International Nuclear Information System (INIS)

    Schelbert, H.R.

    1991-01-01

    The detection of viable myocardium or ischemically injured myocardium with a reversible impairment of contractile function remains clinically important but challenging. Detection of reversible dysfunction and distinction from irreversible tissue injury by positron emission tomography is based on identification of preserved or even enhanced glucose metabolism with F-18 2-fluoro 2-deoxyglucose. Regional patterns of myocardial glucose utilization and blood flow, defined as perfusion-metabolism mismatches or matches, on positron emission tomography in patients with chronic or even acute ischemic heart disease are highly accurate in predicting the functional outcome after interventional revascularization. Compared with thallium-201 redistribution scintigraphy, positron emission tomography appears to be diagnostically more accurate, especially in patients with severely impaired left ventricular function. While larger clinical trials are needed for further confirmation, positron emission tomography has already proved clinically useful for stratifying patients with poor left ventricular function to the most appropriate therapeutic approach

  19. Positron emission tomography for staging of oesophageal and gastroesophageal malignancy

    NARCIS (Netherlands)

    Kole, AC; Plukker, JT; Nieweg, OE; Vaalburg, W

    Positron emission tomography (PET) with [F-18]-fluoro-2-deoxy-D-glucose (FDG) was prospectively investigated as a means of detecting metastatic disease in patients with oesophageal tumours and compared with computerized tomography (CT), with the surgical findings as a gold standard. Twenty-six

  20. Positron emission tomography of incidentally detected small pulmonary nodules

    DEFF Research Database (Denmark)

    Fischer, B M; Mortensen, J; Dirksen, A

    2004-01-01

    The aim of this study was to assess the value of fluorodeoxyglucose positron emission tomography (FDG PET) imaging of small pulmonary nodules incidentally detected by spiral computed tomography (CT) in a high-risk population. Ten patients (five females, five males, aged 54-72 years) were recruited...

  1. Positron emission tomography now and in the future

    International Nuclear Information System (INIS)

    Vaalburg, W.

    1987-01-01

    A survey is given of positron emission tomography used in nuclear medicine. The production of positron emitting radionuclides is discussed. The development of positron detectors is described. The application of positron emission tomography in cardiology, oncology and neurology is treated. The authors conclude that PET is a unique method to examine metabolic processes, although the method is still in its infancy. 7 refs.; 1 table

  2. Shielding design for positron emission tomography facility

    International Nuclear Information System (INIS)

    Abdallah, I.I.

    2007-01-01

    With the recent advent of readily available tracer isotopes, there has been marked increase in the number of hospital-based and free-standing positron emission tomography (PET) clinics. PET facilities employ relatively large activities of high-energy photon emitting isotopes, which can be dangerous to the health of humans and animals. This coupled with the current dose limits for radiation worker and members of the public can result in shielding requirements. This research contributes to the calculation of the appropriate shielding to keep the level of radiation within an acceptable recommended limit. Two different methods were used including measurements made at selected points of an operating PET facility and computer simulations by using Monte Carlo Transport Code. The measurements mainly concerned the radiation exposure at different points around facility using the survey meter detectors and Thermoluminescent Dosimeters (TLD). Then the set of manual calculation procedures were used to estimate the shielding requirements for a newly built PEF facility. The results from the measurement and the computer simulation were compared to the results obtained from the set manual calculation procedure. In general, the estimated weekly dose at the points of interest is lower than the regulatory limits for the little company of Mary Hospital. Furthermore, the density and the HVL for normal strength concrete and clay bricks are almost similar. In conclusion, PET facilities present somewhat different design requirements and are more likely to require additional radiation shielding. Therefore, existing shields at the little Company of Mary Hospital are in general found to be adequate and satisfactory and additional shielding was found necessary at the new PET facility in the department of Nuclear Medicine of the Dr. George Mukhari Hospital. By use of appropriate design, by implying specific shielding requirements and by maintaining good operating practices, radiation doses to

  3. Positron emission tomography and cerebral metabolism

    International Nuclear Information System (INIS)

    Comar, D.; Maziere, M.; Zarifian, E.; Naquet, R.

    1979-01-01

    The association of new methods of labelling with short lived radioisotopes and of visualisation 'in vivo' of these labelled molecules by emission tomography, provide the possibility of studying brain metabolism at different levels. Two examples will illustrate the possibilities of this methodology. Cerebral metabolism of methionine- 11 C in phenylketonutic patients: The cerebral uptake of methionine was measured in 24 PKU children aged 1 to 40 months on a low protein diet. Ten of them were examined twice at intervals of several months. Stopping the diet for one week leads to an increase in blood phenylalanine and to a significant important decrease in brain uptake of labelled methionine. Futhermore, for children under treatment having a low phenylalanine blood concentration, brain uptake of methionine decreases with age between 1 and 40 months. These results suggest that the treatment of this disease should be started as soon as possible after birth. Cerebral metabolism of psychoactive drugs: The study of the brain distribution and kinetics of psychoactive drugs may help in understanding their mode of action. Chlorpromazine- 11 C was administered i.v. to schyzophrenic patients not previously treated with neuroleptics. In all patients the brain uptake of the drug was high and rapid, and was localized mainly in the grey matter, probably in proportion to the blood flow. Non-specific binding of this drug to brain proteins prevented visualization of specific binding to dopaminergic or αnor-adrenergic receptors. Specific receptor binding of benzodiazepines was however visualized in the brain of baboons after injection of 11 C-flunitrazepam (specific activity = 600 Ci/μmole) and subsequent displacement of this radioactive ligand by a pharmacological dose of Lorazepam

  4. Quantifying the limitations of small animal positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Oxley, D.C. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom)], E-mail: dco@ns.ph.liv.ac.uk; Boston, A.J.; Boston, H.C.; Cooper, R.J.; Cresswell, J.R.; Grint, A.N.; Nolan, P.J.; Scraggs, D.P. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury Laboratory, Warrington, WA4 4AD Cheshire (United Kingdom); Beveridge, T.E. [School of Materials and Engineering, Monash University, Melbourne (Australia)

    2009-06-01

    The application of position sensitive semiconductor detectors in medical imaging is a field of global research interest. The Monte-Carlo simulation toolkit GEANT4 [ (http://geant4.web.cern.ch/geant4/)] was employed to improve the understanding of detailed {gamma}-ray interactions within the small animal Positron Emission Tomography (PET), high-purity germanium (HPGe) imaging system, SmartPET [A.J. Boston, et al., Oral contribution, ANL, Chicago, USA, 2006]. This system has shown promising results in the field of PET [R.J. Cooper, et al., Nucl. Instr. and Meth. A (2009), accepted for publication] and Compton camera imaging [J.E. Gillam, et al., Nucl. Instr. and Meth. A 579 (2007) 76]. Images for a selection of single and multiple point, line and phantom sources were successfully reconstructed using both a filtered-back-projection (FBP) [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007] and an iterative reconstruction algorithm [A.R. Mather, Ph.D. Thesis, University of Liverpool, 2007]. Simulated data were exploited as an alternative route to a reconstructed image allowing full quantification of the image distortions introduced in each phase of the data processing. Quantifying the contribution of uncertainty in all system components from detector to reconstruction algorithm allows the areas in need of most attention on the SmartPET project and semiconductor PET to be addressed.

  5. Recurrent ovarian endodermal sinus tumor: demonstration by computed tomography, magnetic resonance imaging, and positron emission tomography

    International Nuclear Information System (INIS)

    Romero, J.A.; Kim, E.E.; Tresukosol, D.; Kudelka, A.P.; Edwards, C.L.; Kavanagh, J.J.

    1995-01-01

    We report a case of recurrent endodermal sinus tumor of the ovary that was identified and/or clearly depicted by computed tomography, magnetic resonance imaging, and positron emission tomography. The potential roles of various imaging modalities in the detection of recurrent endodermal sinus tumor are discussed. (orig.)

  6. Fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography in evaluation of residual intramuscular myxoma

    International Nuclear Information System (INIS)

    Zade, Anand; Ahire, Archana; Shetty, Shishir; Rai, Sujith; Bokka, Rajashekharrao; Velumani, Arokiaswamy; Kabnurkar, Rasika

    2015-01-01

    Intramuscular myxoma (IM) is a rare benign neoplasm. In a patient diagnosed with IM of left thigh, we report the utility of a postoperative fluorine-18 fluorodeoxyglucose positron emission tomography-computed tomography scan in assessing the efficacy of surgical excision

  7. Positron emission tomography-computed tomography has a clinical impact for patients with cervical cancer

    DEFF Research Database (Denmark)

    Sandvik, Rikke Mulvad; Jensen, Pernille Tine; Hendel, Helle W

    2011-01-01

    Many studies have found that positron emission tomography-computed tomography (PET-CT) has a high sensitivity and specificity in the identification of metastasis in cervical cancer. Herlev Hospital, Denmark, has been performing PET-CTs in stage I-IV cervical cancer since 1 May 2006. The present...

  8. Diffuse nesidioblastosis diagnosed on a Ga-68 DOTATATE positron emission tomography/computerized tomography

    International Nuclear Information System (INIS)

    Arun, Sasikumar; Mittal, Bhagwant Rai; Shukla, Jaya; Bhattacharya, Anish; Kumar, Praveen

    2013-01-01

    The authors describe a 50 days old pre-term infant with persistent hyperinsulinemic hypoglycemia of infancy in whom 68 Ga DOTATATE positron emission tomography/computerized tomography scan showed diffusely increased tracer uptake in the entire pancreas with no abnormal tracer uptake anywhere else in the body, suggestive of a diffuse variant of nesidioblastosis. (author)

  9. Role of albedo from the Gamma-400 telescope calorimeter when recording the primary gamma emission.

    Science.gov (United States)

    Ginsburg, V. L.; Kurnosova, L. V.; Labensky, A. G.; Topchiev, N. P.; Fradkin, M. I.; Kaplin, V. A.; Kaplin, D. V.; Loginov, V. A.; Maklyaev, E. F.; Runtso, M. F.; Gorchakov, E. V.

    A calorimeter albedo emission affecting the Gamma-400 telescope operation is studied, when recording γ-quanta at energies from 10 to 1000 GeV. Methods for diminishing this impact on measuring data are proposed.

  10. Gamma-ray emission from internal shocks in novae

    Science.gov (United States)

    Martin, P.; Dubus, G.; Jean, P.; Tatischeff, V.; Dosne, C.

    2018-04-01

    Context. Gamma-ray emission at energies ≥100 MeV has been detected from nine novae using the Fermi Large Area Telescope (LAT), and can be explained by particle acceleration at shocks in these systems. Eight out of these nine objects are classical novae in which interaction of the ejecta with a tenuous circumbinary material is not expected to generate detectable gamma-ray emission. Aim. We examine whether particle acceleration at internal shocks can account for the gamma-ray emission from these novae. The shocks result from the interaction of a fast wind radiatively-driven by nuclear burning on the white dwarf with material ejected in the initial runaway stage of the nova outburst. Methods: We present a one-dimensional model for the dynamics of a forward and reverse shock system in a nova ejecta, and for the associated time-dependent particle acceleration and high-energy gamma-ray emission. Non-thermal proton and electron spectra are calculated by solving a time-dependent transport equation for particle injection, acceleration, losses, and escape from the shock region. The predicted emission is compared to LAT observations of V407 Cyg, V1324 Sco, V959 Mon, V339 Del, V1369 Cen, and V5668 Sgr. Results: The ≥100 MeV gamma-ray emission arises predominantly from particles accelerated up to 100 GeV at the reverse shock and undergoing hadronic interactions in the dense cooling layer downstream of the shock. The emission rises within days after the onset of the wind, quickly reaches a maximum, and its subsequent decrease reflects mostly the time evolution of the wind properties. Comparison to gamma-ray data points to a typical scenario where an ejecta of mass 10-5-10-4 M⊙ expands in a homologous way with a maximum velocity of 1000-2000 km s-1, followed within a day by a wind with a velocity values of which result in the majority of best-fit models having gamma-ray spectra with a high-energy turnover below 10 GeV. Our typical model is able to account for the main

  11. Emission tomography: quantitative aspects in metabolic and physio-pathologic studies

    International Nuclear Information System (INIS)

    Yerouchalmi-Soussaline, F.

    1984-01-01

    This thesis presents instrumental and data processing studies developed in emission tomography in man, using gamma and positron emitting tracers. High contrast visualisation of volume distribution of tracers in the organs, kinetic studies and measurements of radioactive concentration or of other clinical parameters necessitate a detailed analysis of all physical factors limiting the accuracy of the measure; therefore, development of adapted imaging devices and data processing techniques, together with models describing correctly the phenomena under study are to be carried out. Thus, in single photon (gamma) emission tomography an image reconstruction strategy is elaborated, based on an analytical model for the ill-posed problem including the attenuation effect. In positron emission tomography, the time-of-flight information combined with the reconstruction technique is used in the design of a first prototype imaging device which performance is presented and evaluated in a clinical environment. Moreover, a priori or a posteriori techniques correcting for Compton diffusion events, limited statistics and limited resolution, are proposed and discussed for the improvement of regional measurement accuracy, in metabolic and physio-pathologic studies. (author) [fr

  12. Hybrid Single Photon Emission Computed Tomography/Computed Tomography Sulphur Colloid Scintigraphy in Focal Nodular Hyperplasia

    International Nuclear Information System (INIS)

    Bhoil, Amit; Gayana, Shankramurthy; Sood, Ashwani; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2013-01-01

    It is important to differentiate focal nodular hyperplasia (FNH), a benign condition of liver most commonly affecting women, from other neoplasm such as hepatic adenoma and metastasis. The functional reticuloendothelial features of FNH can be demonstrated by scintigraphy. We present a case of breast cancer in whom fluorodeoxyglucose positron emission tomography/computerized tomography (CT) showed a homogenous hyperdense lesion in liver, which on Tc99m sulfur colloid single-photon emission computed tomography/CT was found to have increased focal tracer uptake suggestive of FNH

  13. Positron emission tomography and migraine. Tomographie par emission de positons et migraine

    Energy Technology Data Exchange (ETDEWEB)

    Chabriat, H. (CEA, 91 - Orsay (France). Service Hospitalier Frederic Joliot)

    1992-04-01

    Positron emission tomography (PET) is a brain imaging technique that allows in vivo studies of numerous physiological parameters. There have been few PET studies in migraine patients. Cerebral blood flow changes with no variations in brain oxygen consumption have been reported in patients with prolonged neurologic manifestations during migraine attacks. Parenteral administration of reserpine during migraine headache has been followed by a fall in the overall cerebral uptake of glucose. The small sample sizes and a number of methodologic problems complicate the interpretation of these results. Recent technical advances and the development of new PET tracers can be expected to provide further insight into the pathophysiology of migraine. Today cerebral cortex 5 HT{sub 2} serotonin receptors can be studied in migraine patients with PET.

  14. A link between prompt optical and prompt gamma-ray emission in gamma-ray bursts.

    Science.gov (United States)

    Vestrand, W T; Wozniak, P R; Wren, J A; Fenimore, E E; Sakamoto, T; White, R R; Casperson, D; Davis, H; Evans, S; Galassi, M; McGowan, K E; Schier, J A; Asa, J W; Barthelmy, S D; Cummings, J R; Gehrels, N; Hullinger, D; Krimm, H A; Markwardt, C B; McLean, K; Palmer, D; Parsons, A; Tueller, J

    2005-05-12

    The prompt optical emission that arrives with the gamma-rays from a cosmic gamma-ray burst (GRB) is a signature of the engine powering the burst, the properties of the ultra-relativistic ejecta of the explosion, and the ejecta's interactions with the surroundings. Until now, only GRB 990123 had been detected at optical wavelengths during the burst phase. Its prompt optical emission was variable and uncorrelated with the prompt gamma-ray emission, suggesting that the optical emission was generated by a reverse shock arising from the ejecta's collision with surrounding material. Here we report prompt optical emission from GRB 041219a. It is variable and correlated with the prompt gamma-rays, indicating a common origin for the optical light and the gamma-rays. Within the context of the standard fireball model of GRBs, we attribute this new optical component to internal shocks driven into the burst ejecta by variations of the inner engine. The correlated optical emission is a direct probe of the jet isolated from the medium. The timing of the uncorrelated optical emission is strongly dependent on the nature of the medium.

  15. ISPA - a high accuracy X-ray and gamma camera Exhibition LEPFest 2000

    CERN Multimedia

    2000-01-01

    ISPA offers ... Ten times better resolution than Anger cameras High efficiency single gamma counting Noise reduction by sensitivity to gamma energy ...for Single Photon Emission Computed Tomography (SPECT)

  16. Positron-molecule interactions and corresponding positron attachment to molecules. As a basis for positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Tachikawa, Masanori; Kimura, Mineo; Pichl, Lukas

    2007-01-01

    Through positron and electron interactions, they annihilate emitting primarily two gamma rays with 180-degree opposite directions. Positron spectroscopy using the characteristics of these gamma rays has been employed for analyzing various properties of material as well as for positron emission tomography (PET). However, its fundamental physics of positron-electron interactions and resulting features of emitting gamma rays are not well understood. By obtaining better understanding of positron interactions, it should become possible to provide the firm bases for positron spectroscopy in finer accuracy and quality. Here, we propose a significant mechanism for positron annihilation through positron attachment process, which may help increase the quality of positron spectroscopy. (author)

  17. Single photon emission computed tomography and oth selected computer topics

    International Nuclear Information System (INIS)

    Frey, G.D.

    1981-01-01

    This book, the proceedings of a meeting in January 1980, contains 21 papers. Thirteen are devoted to aspects of emission tomography, four to nuclear cardiology, and five to other topics. The initial set of papers consists of reviews of the single photon emission tomography process. These include transverse axial tomography using scintillation cameras and other devices, longitudinal section tomography, and pin-hole and slant-hole systems. These reviews are generally well done, but as might be expected, lack any coherence from paper to paper. The papers on nuclear cardiology include several of Fourier analysis in nuclear cardiology and one on shunt quantification. Other clinical papers are on quantifying Tc-99m glucoheptonate uptake in the brain and on iron-59 retention studies. A general criticism of the book is the poor quality of photographic reproductions

  18. Characterisation of high-burnup LWR fuel rods through gamma tomography

    International Nuclear Information System (INIS)

    Caruso, S.

    2007-01-01

    Current fuel management strategies for light water reactors (LWRs), in countries with high back-end costs, progressively extend the discharge burnup at the expense of increasing the 235 U enrichment of the fresh UO 2 fuel loaded. In this perspective, standard non-destructive assay techniques, which are very attractive because they are fast, cheap, and preserve the fuel integrity, in contrast to destructive approaches, require further validation when burnup values become higher than 50 GWd/t. This doctoral work has been devoted to the development and optimisation of non-destructive assay techniques based on gamma-ray emissions from irradiated fuel. It represents an important extension of the unique, high-burnup related database, generated in the framework of the LWR PROTEUS Phase II experiments. A novel tomographic measurement station has been designed and developed for the investigation of irradiated fuel rod segments. A unique feature of the station is that it allows both gamma-ray transmission and emission computerised tomography to be performed on single fuel rods. Four burnt UO 2 fuel rod segments of 400 mm length have been investigated, two with very high (52 GWd/t and 71 GWd/t) and two with ultra-high (91 GWd/t and 126 GWd/t) burnup. Several research areas have been addressed, as described below. The application of transmission tomography to spent fuel rods has been a major task, because of difficulties of implementation and the uniqueness of the experiments. The main achievements, in this context, have been the determination of fuel rod average material density (a linear relationship between density and burnup was established), fuel rod linear attenuation coefficient distribution (for use in emission tomography), and fuel rod material density distribution. The non-destructive technique of emission computerised tomography (CT) has been applied to the very high and ultra-high burnup fuel rod samples for determining their within-rod distributions of caesium and

  19. Brain receptor single-photon emission computer tomography with 123I Datscan in Parkinson's disease

    International Nuclear Information System (INIS)

    Minchev, D.; Peshev, N.; Kostadinova, I.; Grigorova, O.; Trindev, P.; Shotekov, P.

    2005-01-01

    Clinical aspects of Parkinson's disease are not enough for the early diagnosis of the disease. Positron emission tomography and the receptor single - photon emission tomography can be used for imaging functional integrity of nigrostriatal dopaminergic structures. 24 patient (17 men and 7 women) were investigated. 20 of them are with Parkinson's disease and 4 are with essential tremor. The radiopharmaceutical - 123I-Datscan (ioflupane, bind with 123I) represent a cocaine analogue with selective affinity to dopamine transporters, located in the dopaminergic nigrostriatal terminals in the striatum. Single - photon emission computer tomography was performed with SPECT gamma camera (ADAC, SH Epic detector). The scintigraphic study was made 3 to 6 hours after intravenous injection of the radiopharmaceutical - 123I- Datscan in dose 185 MBq. 120 frames are registered with duration of each one 22 seconds and gamma camera rotation 360. After generation of transversal slices we generated two composites pictures. The first composite picture image the striatum, the second - the occipital region. Two ratios were calculated representing the uptake of the radiopharmaceutical in the left and right striatum. Qualitative and quantitative criteria were elaborated for evaluating the scintigraphic patterns. Decreased, nonhomogeneous and asymmetric uptake of the radiopharmaceutical coupled with low quantitative parameters in range from 1.44 to 2.87 represents the characteristic scintigraphic pattern for Parkinson's disease with clear clinical picture. Homogenous with high intensity and symmetric uptake of the radiopharmaceutical in the striatum coupled with his clear frontier and with quantitative parameters up to 4.40 represent the scintigraphic pattern in two patients with essential tremor. Receptor single - photon emission computer tomography with 123I - Datscan represents an accurate nuclear-medicine method for precise diagnosis of Parkinson's disease and for its differentiation from

  20. Diagnosis of dementia with single photon emission computed tomography

    International Nuclear Information System (INIS)

    Jagust, W.J.; Budinger, T.F.; Reed, B.R.

    1987-01-01

    Single photon emission computed tomography is a practical modality for the study of physiologic cerebral activity in vivo. We utilized single photon emission computed tomography and N-isopropyl-p-iodoamphetamine iodine 123 to evaluate regional cerebral blood flow in nine patients with Alzheimer's disease (AD), five healthy elderly control subjects, and two patients with multi-infarct dementia. We found that all subjects with AD demonstrated flow deficits in temporoparietal cortex bilaterally, and that the ratio of activity in bilateral temporoparietal cortex to activity in the whole slice allowed the differentiation of all patients with AD from both the controls and from the patients with multi-infarct dementia. Furthermore, this ratio showed a strong correlation with disease severity in the AD group. Single photon emission computed tomography appears to be useful in the differential diagnosis of dementia and reflects clinical features of the disease

  1. Analysis of concrete material through gamma ray computerized tomography

    International Nuclear Information System (INIS)

    Oliveira Junior, J.M. de

    2004-01-01

    Computerized Tomography (CT) refers to the cross sectional imaging of an object from both transmission or reflection data collected by illuminating the object from many different directions. The most important contribution of CT is to greatly improve abilities to distinguish regions with different gamma ray transmittance and to separate over-lying structures. The mathematical problem of the CT imaging is that of estimating an image from its projections. These projections can represent, for example, the linear attenuation coefficient of γ-rays along the path of the ray. In this work we will present some new results obtained by using tomographic techniques to analyze column samples of concrete to check the distribution of various materials and structural problems. These concrete samples were made using different proportions of stone, sand and cement. Another set of samples with different proportions of sand and cement were also used to verify the outcome from the CT analysis and the differences between them. Those samples were prepared at the Material Laboratory of Faculdade de Engenharia de Sorocaba, following the same procedures used in real case of concrete tests. The projections used in this work was obtained by Mini Computerized Tomograph of Uniso (MTCU), located at the Experimental Nuclear Physics Laboratory at University of Sorocaba. This tomograph operates with a gamma ray source of 241 Am (photons of 60 keV and 100 mCi of intensity) and a NaI(Tl) solid state detector. The system features translation and rotation scanning modes, a 100 mm effective field of view, and 1 mm spatial resolution. The image reconstruction problem is solved using Discrete Filtered Backprojection (FBP). (author)

  2. Simulating Gamma-Ray Emission in Star-forming Galaxies

    Energy Technology Data Exchange (ETDEWEB)

    Pfrommer, Christoph [Leibniz-Institut für Astrophysik Potsdam (AIP), An der Sternwarte 16, D-14482 Potsdam (Germany); Pakmor, Rüdiger; Simpson, Christine M.; Springel, Volker, E-mail: cpfrommer@aip.de [Heidelberg Institute for Theoretical Studies, Schloss-Wolfsbrunnenweg 35, D-69118 Heidelberg (Germany)

    2017-10-01

    Star-forming galaxies emit GeV and TeV gamma-rays that are thought to originate from hadronic interactions of cosmic-ray (CR) nuclei with the interstellar medium. To understand the emission, we have used the moving-mesh code Arepo to perform magnetohydrodynamical galaxy formation simulations with self-consistent CR physics. Our galaxy models exhibit a first burst of star formation that injects CRs at supernovae. Once CRs have sufficiently accumulated in our Milky Way–like galaxy, their buoyancy force overcomes the magnetic tension of the toroidal disk field. As field lines open up, they enable anisotropically diffusing CRs to escape into the halo and to accelerate a bubble-like, CR-dominated outflow. However, these bubbles are invisible in our simulated gamma-ray maps of hadronic pion-decay and secondary inverse-Compton emission because of low gas density in the outflows. By adopting a phenomenological relation between star formation rate (SFR) and far-infrared emission and assuming that gamma-rays mainly originate from decaying pions, our simulated galaxies can reproduce the observed tight relation between far-infrared and gamma-ray emission, independent of whether we account for anisotropic CR diffusion. This demonstrates that uncertainties in modeling active CR transport processes only play a minor role in predicting gamma-ray emission from galaxies. We find that in starbursts, most of the CR energy is “calorimetrically” lost to hadronic interactions. In contrast, the gamma-ray emission deviates from this calorimetric property at low SFRs due to adiabatic losses, which cannot be identified in traditional one-zone models.

  3. Simulating Gamma-Ray Emission in Star-forming Galaxies

    Science.gov (United States)

    Pfrommer, Christoph; Pakmor, Rüdiger; Simpson, Christine M.; Springel, Volker

    2017-10-01

    Star-forming galaxies emit GeV and TeV gamma-rays that are thought to originate from hadronic interactions of cosmic-ray (CR) nuclei with the interstellar medium. To understand the emission, we have used the moving-mesh code Arepo to perform magnetohydrodynamical galaxy formation simulations with self-consistent CR physics. Our galaxy models exhibit a first burst of star formation that injects CRs at supernovae. Once CRs have sufficiently accumulated in our Milky Way-like galaxy, their buoyancy force overcomes the magnetic tension of the toroidal disk field. As field lines open up, they enable anisotropically diffusing CRs to escape into the halo and to accelerate a bubble-like, CR-dominated outflow. However, these bubbles are invisible in our simulated gamma-ray maps of hadronic pion-decay and secondary inverse-Compton emission because of low gas density in the outflows. By adopting a phenomenological relation between star formation rate (SFR) and far-infrared emission and assuming that gamma-rays mainly originate from decaying pions, our simulated galaxies can reproduce the observed tight relation between far-infrared and gamma-ray emission, independent of whether we account for anisotropic CR diffusion. This demonstrates that uncertainties in modeling active CR transport processes only play a minor role in predicting gamma-ray emission from galaxies. We find that in starbursts, most of the CR energy is “calorimetrically” lost to hadronic interactions. In contrast, the gamma-ray emission deviates from this calorimetric property at low SFRs due to adiabatic losses, which cannot be identified in traditional one-zone models.

  4. Quantification in single photon emission computed tomography (SPECT)

    International Nuclear Information System (INIS)

    Buvat, Irene

    2005-01-01

    The objective of this lecture is to understand the possibilities and limitations of the quantitative analysis of single photon emission computed tomography (SPECT) images. It is also to identify the conditions to be fulfilled to obtain reliable quantitative measurements from images. Content: 1 - Introduction: Quantification in emission tomography - definition and challenges; quantification biasing phenomena; 2 - quantification in SPECT, problems and correction methods: Attenuation, scattering, un-stationary spatial resolution, partial volume effect, movement, tomographic reconstruction, calibration; 3 - Synthesis: actual quantification accuracy; 4 - Beyond the activity concentration measurement

  5. New detector developments for high resolution positron emission tomography

    International Nuclear Information System (INIS)

    Ziegler, S.I.; Pichler, B.; Lorenz, E.

    1998-01-01

    The strength of quantitative, functional imaging using positron emission tomography, specially in small animals, is limited due to the spatial resolution. Therefore, various tomograph designs employing new scintillators, light sensors, or coincidence electronic are investigated to improve resolution without losses in sensitivity. Luminous scintillators with short light decay time in combination with novel readout schemes using photomultipliers or semiconductor detectors are currently tested by several groups and are implemented in tomographs for small animals. This review summarises the state of development in high resolution positron emission tomography with a detailed description of a system incorporating avalanche photodiode arrays and small scintillation crystals. (orig.) [de

  6. Positron emission tomography in oncology. Council on Scientific Affairs

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report describes the current and potential uses of positron emission tomography in clinical medicine and research related to oncology. Assessment will be possible of metabolism and physiology of tumors and their effects on adjacent tissues. Specific probes are likely to be developed for target sites on tumors, including monoclonal antibodies and specific growth factors that recognize tumors. To date, most oncological applications of positron emission tomography tracers have been qualitative; in the future, quantitative metabolic measurements should aid in the evaluation of tumor biology and response to treatment. 41 references

  7. Positron emission tomography in the evaluation of subdural hematomas

    International Nuclear Information System (INIS)

    Ericson, K.; Bergstroem, M.; Eriksson, L.

    1980-01-01

    Fifteen patients with 21 subdural effusions were investigated both with transmission computer assisted tomography (CAT) and positron emission tomography (PET). The tracer in the emission studies was 68 Ga-EDTA. Twelve lesions were visualized both with CAT and PET. Five lesions that were negative or doubtful on CAT were visualized with PET, whereas four lesions negative or doubtful on PET were demonstrated by CAT. The two methods complement each other due to the fact that they are based on different mechanisms: CAT mainly on attenuation of the fluid collection. PET on isotope accumulation, particularly in the hematoma membranes

  8. 134Cs emission probabilities determination by gamma spectrometry

    Science.gov (United States)

    de Almeida, M. C. M.; Poledna, R.; Delgado, J. U.; Silva, R. L.; Araujo, M. T. F.; da Silva, C. J.

    2018-03-01

    The National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) of Rio de Janeiro performed primary and secondary standardization of different radionuclides reaching satisfactory uncertainties. A solution of 134Cs radionuclide was purchased from commercial supplier to emission probabilities determination of some of its energies. 134Cs is a beta gamma emitter with 754 days of half-life. This radionuclide is used as standard in environmental, water and food control. It is also important to germanium detector calibration. The gamma emission probabilities (Pγ) were determined mainly for some energies of the 134Cs by efficiency curve method and the Pγ absolute uncertainties obtained were below 1% (k=1).

  9. $\\gamma$-Ray Pulsars: Emission Zones and Viewing Geometries

    OpenAIRE

    Romani, Roger W.; Yadigaroglu, I. -A.

    1994-01-01

    There are now a half dozen young pulsars detected in high energy photons by the Compton GRO, showing a variety of emission efficiencies and pulse profiles. We present here a calculation of the pattern of high energy emission on the sky in a model which posits $\\gamma$-ray production by charge depleted gaps in the outer magnetosphere. This model accounts for the radio to $\\gamma$-ray pulse offsets of the known pulsars, as well as the shape of the high energy pulse profiles. We also show that $...

  10. Homotopic non-local regularized reconstruction from sparse positron emission tomography measurements

    International Nuclear Information System (INIS)

    Wong, Alexander; Liu, Chenyi; Wang, Xiao Yu; Fieguth, Paul; Bie, Hongxia

    2015-01-01

    Positron emission tomography scanners collect measurements of a patient’s in vivo radiotracer distribution. The system detects pairs of gamma rays emitted indirectly by a positron-emitting radionuclide (tracer), which is introduced into the body on a biologically active molecule, and the tomograms must be reconstructed from projections. The reconstruction of tomograms from the acquired PET data is an inverse problem that requires regularization. The use of tightly packed discrete detector rings, although improves signal-to-noise ratio, are often associated with high costs of positron emission tomography systems. Thus a sparse reconstruction, which would be capable of overcoming the noise effect while allowing for a reduced number of detectors, would have a great deal to offer. In this study, we introduce and investigate the potential of a homotopic non-local regularization reconstruction framework for effectively reconstructing positron emission tomograms from such sparse measurements. Results obtained using the proposed approach are compared with traditional filtered back-projection as well as expectation maximization reconstruction with total variation regularization. A new reconstruction method was developed for the purpose of improving the quality of positron emission tomography reconstruction from sparse measurements. We illustrate that promising reconstruction performance can be achieved for the proposed approach even at low sampling fractions, which allows for the use of significantly fewer detectors and have the potential to reduce scanner costs

  11. 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography in Tuberculosis: Spectrum of Manifestations.

    Science.gov (United States)

    Agarwal, Krishan Kant; Behera, Abhishek; Kumar, Rakesh; Bal, Chandrasekhar

    2017-01-01

    The objective of this article is to provide an illustrative tutorial highlighting the utility of 18 F-fluorodeoxyglucose-positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) imaging to detect spectrum of manifestations in patients with tuberculosis (TB). FDG-PET/CT is a powerful tool for early diagnosis, measuring the extent of disease (staging), and consequently for evaluation of response to therapy in patients with TB.

  12. Gamma-ray pulsars: Emission zones and viewing geometries

    Science.gov (United States)

    Romani, Roger W.; Yadigaroglu, I.-A.

    1995-01-01

    There are now a half-dozen young pulsars detected in high-energy photons by the Compton Gamma-Ray Observatory (CGRO), showing a variety of emission efficiencies and pulse profiles. We present here a calculation of the pattern of high-energy emission on the sky in a model which posits gamma-ray production by charge-depleted gaps in the outer magnetosphere. This model accounts for the radio to gamma-ray pulse offsets of the known pulsars, as well as the shape of the high-energy pulse profiles. We also show that about one-third of emitting young radio pulsars will not be detected due to beaming effects, while approximately 2.5 times the number of radio-selected gamma-ray pulsars will be viewed only high energies. Finally we compute the polarization angle variation and find that the previously misunderstood optical polarization sweep of the Crab pulsar arises naturally in this picture. These results strongly support an outer magnetosphere location for the gamma-ray emission.

  13. Submillimeter medical imaging in emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lang, C.; Thirolf, P.G. [LMU, Muenchen (Germany); Habs, D. [LMU, Muenchen (Germany); MPQ, Garching (Germany); Zoglauer, A. [SSL, Berkeley (United States)

    2012-07-01

    We present a nuclear medical imaging technique, capable to reach submillimeter spatial resolution in 3 dimensions with a short exposure time and a low radioactive dose compared to conventional PET. This '{gamma}-PET' technique takes advantage of specific e{sup +} sources which simultaneously with the {beta}{sup +} decay emit an additional photon. Exploiting the triple coincidence between the positron annihilation and the additional emitted {gamma}, it is possible to separate the reconstructed 'true' events from background. Thus the spatial uncertainty introduced by the motion of the e{sup +} or by Compton scattering within the patient can be strongly reduced in the direction normal to the annihilation. MC-simulations and image reconstruction studies have been performed using the library MEGAlib, which we modified to realize an event reconstruction using the {beta}{sup +}{gamma} coincidences. The simulated geometry consists of 4 LaBr{sub 3} scintillator crystals (5 x 5 x 3 cm{sup 3}) read out by a 2D-segmented photomultiplier (64 pixels, each 6 x 6 mm{sup 2}) and 4 double-sided silicon strip detectors (each with 2 x 128 strips, active area of 5 x 5 cm{sup 2}, thickness 0.5 mm), positioned around an H{sub 2}O sphere of 6 cm diameter. Inside are two {sup 22}Na point-like test sources, placed at a distance of 0.4 mm. The resolution results in 0.2 mm (FWHM) in each direction, surpassing the performance of conventional PET by about an order of magnitude.

  14. Positron emission tomography of malignant tumours at head and neck. Evaluation of the diagnostic value of positron emission tomography by comparison with computed tomography

    International Nuclear Information System (INIS)

    Kettler, Nele

    2011-01-01

    Imaging methods for early, accurate diagnosis and aftercare of malignant growths is currently one of the most important research topics. The objective of this thesis is to evaluate the diagnostic value of FDG-positron emission tomography by comparison with computed tomography for patients with squamous cell carcinoma, malignant melanoma or sarcoma at head and neck. Measurement criteria are sensitivity and specificity. A retrospective evaluation of 100 examinations on 85 patients of University clinic Aachen was performed. The examination reports were supported by reports from histology, positron emission tomography and computed tomography. In each case, the histological results were assumed to provide a reliable benchmark. Sensitivity and specificity for the primary tumour site, metastatic lymphatic nodes and defined anatomic structures were compared across all patients. Comparisons were also performed on sub groups separated by gender, cancer type and the time and frequency at which tumours arose. The statistic analysis was done with MedCalc. Results: The results for sensitivity and specificity of the primary tumour site were 86.42% and 42.86%, and 64.71% and 66.07%, for positron emission tomography and computed tomography respectively. The results for the lymphatic nodes were 51.52% and 92.86% and 64.71% and 66.07%. When the constituent anatomic structures were evaluated separately, the specificity was significantly higher. The separation by gender showed no difference. Because the classification by tumor type resulted in samples that were of varying size, a comparison was difficult. For the diagnosis of primary tumours, the examination with positron emission tomography was superior, whereas computed tomography proved more effective for the diagnosis of recurrent tumours. For the diagnosis of the main tumour site, both methods were shown to be equally suitable. For the assessment of lymphatic nodes, positron emission tomography was superior to computed tomography

  15. 3D fast reconstruction in positron emission tomography

    International Nuclear Information System (INIS)

    Egger, M.L.; Scheurer, A. Hermann; Joseph, C.; Morel, C.

    1996-01-01

    The issue of long reconstruction times in positron emission tomography (PET) has been addressed from several points of view, resulting in an affordable dedicated system capable of handling routine 3D reconstructions in a few minutes per frame : on the hardware side using fast processors and a parallel architecture, and on the software side, using efficient implementation of computationally less intensive algorithms

  16. Time-of-flight positron emission tomography and associated detectors

    International Nuclear Information System (INIS)

    Vacher, J.; Allemand, R.; Campagnolo, R.

    1983-04-01

    An analysis of the timing capabilities of the detectors (scintillators and photomultipliers) in time-of-flight positron emission tomography is presented. The advantages of BaF 2 compared with CsF for the futur tomographs are evaluated [fr

  17. Cobalt-55 positron emission tomography in recurrent ischaemic stroke

    NARCIS (Netherlands)

    De Reuck, J; Santens, P; Keppens, J; De Bleecker, J; Strijckmans, K; Goethals, P; Lemahieu, [No Value; Korf, J

    The present study investigates if Cobalt-55 (Co-55) positron emission tomography (PET) allows us to distinguish and detect recent, recurrent strokes in patients who had already suffered a previous infarct in the same vascular territory. Fourteen patients with recurrent strokes underwent a Co-55 PET

  18. Measurement of absolute bone blood flow by positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nahmias, C.; Cockshott, W.P.; Garnett, E.S.; Belbeck, L.W.

    1986-03-01

    A method of measuring bone blood flow has been developed using /sup 18/F sodium fluoride and positron emission tomography. The blood flow levels are in line with those obtained experimentally from microsphere embolisation. This investigative method could be applied to elucidate a number of clinical questions involving bone perfusion.

  19. Positron emission tomography in drug development and drug evaluation

    NARCIS (Netherlands)

    Paans, AMJ; Vaalburg, W

    2000-01-01

    Positron Emission Tomography (PET) is an imaging modality which can determine biochemical and physiological processes in vivo in a quantitative way by using radiopharmaceuticals labeled with positron emitting radionuclides as C-11, N-13, O-15 and F-18 and by measuring the annihilation radiation

  20. MR imaging and positron emission tomography of cortical heterotopia

    Energy Technology Data Exchange (ETDEWEB)

    Bairamian, D.; Di Chiro, G.; Theodore, W.H.; Holmes, M.D.; Dorwart, R.H.; Larson, S.M.

    1985-11-01

    Heterotopia of the gray matter is a developmental malformation in which ectopic cortex is found in the white matter of the brain. A case of a 33-year-old man with cortical heterotopia who had a lifelong history of seizures and psychomotor retardation is reported, including the results of cerebral CT, magnetic resonance imaging, and positron emission tomography using YF-2-deoxyglucose.

  1. MR imaging and positron emission tomography of cortical heterotopia

    International Nuclear Information System (INIS)

    Bairamian, D.; Di Chiro, G.; Theodore, W.H.; Holmes, M.D.; Dorwart, R.H.; Larson, S.M.

    1985-01-01

    Heterotopia of the gray matter is a developmental malformation in which ectopic cortex is found in the white matter of the brain. A case of a 33-year-old man with cortical heterotopia who had a lifelong history of seizures and psychomotor retardation is reported, including the results of cerebral CT, magnetic resonance imaging, and positron emission tomography using 18 F-2-deoxyglucose

  2. Amyloid-β positron emission tomography imaging probes

    DEFF Research Database (Denmark)

    Kepe, Vladimir; Moghbel, Mateen C; Långström, Bengt

    2013-01-01

    , a number of factors appear to preclude these probes from clinical utilization. As the available "amyloid specific" positron emission tomography imaging probes have failed to demonstrate diagnostic value and have shown limited utility for monitoring therapeutic interventions in humans, a debate...

  3. Positron Emission Tomography : background, possibilities and perspectives in neuroscience

    NARCIS (Netherlands)

    Paans, AMJ

    Positron Emission Tomography (PET) is a method for determining biochemical and physiological processes in vivo in a quantitative way. This includes the measurement of the pharmacokinetics of labeled drugs and the measurement of the effects of drugs and/or therapy on metabolism. Also deviations of

  4. Physiopathology of ischemic strokes: the input of positron emission tomography

    International Nuclear Information System (INIS)

    Steinling, M.; Samson, Y.

    1999-01-01

    The tomography by positrons emissions has brought essential physiological and pathological knowledge relative to cerebral vascular accidents in the acute phase, because it is possible to measure the cerebral blood flow, the oxygen extraction rate and the local oxygen consumption. (N.C.)

  5. High resolution and high speed positron emission tomography data acquisition

    International Nuclear Information System (INIS)

    Burgiss, S.G.; Byars, L.G.; Jones, W.F.; Casey, M.E.

    1986-01-01

    High resolution positron emission tomography (PET) requires many detectors. Thus, data collection systems for PET must have high data rates, wide data paths, and large memories to histogram the events. This design uses the VMEbus to cost effectively provide these features. It provides for several modes of operation including real time sorting, list mode data storage, and replay of stored list mode data

  6. Positron emission tomography in presurgical diagnosis of partial epilepsies

    International Nuclear Information System (INIS)

    Hajek, M.; Leenders, K.L.; Wieser, H.G.

    1992-01-01

    We present results of studies in which positron emission tomography was applied to the presurgical evaluation of epileptics. Emphasis is placed on results of PET studies with various tracers in partial epilepsies and on the use of PET in age-related epileptic syndromes in children. (orig.) [de

  7. Serotonin synthesis studied with positron emission tomography, (PET)

    DEFF Research Database (Denmark)

    Honoré, Per Gustaf Hartvig; Lundquist, Pinelopi

    Positron emission tomography (PET) has the potential to study the biosynthesis and release of serotonin (5HT) at brain serotonergic neurons. PET requires probe compounds with specific attributes to enable imaging and quantification of biological processes. This section focuses on probes to measure...

  8. Recent developments in positron emission tomography (PET) instrumentation

    Energy Technology Data Exchange (ETDEWEB)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs.

  9. Recent developments in positron emission tomography (PET) instrumentation

    International Nuclear Information System (INIS)

    Derenzo, S.E.; Budinger, T.F.

    1986-04-01

    This paper presents recent detector developments and perspectives for positron emission tomography (PET) instrumentation used for medical research, as well as the physical processes in positron annihilation, photon scattering and detection, tomograph design considerations, and the potentials for new advances in detectors. 117 refs., 4 figs., 4 tabs

  10. Quantification in dynamic and small-animal positron emission tomography

    NARCIS (Netherlands)

    Disselhorst, Johannes Antonius

    2011-01-01

    This thesis covers two aspects of positron emission tomography (PET) quantification. The first section addresses the characterization and optimization of a small-animal PET/CT scanner. The sensitivity and resolution as well as various parameters affecting image quality (reconstruction settings, type

  11. Observations of gamma-ray emission in solar flares

    International Nuclear Information System (INIS)

    Forrest, D.J.; Chupp, E.L.; Suri, A.N.; Reppin, C.

    1973-01-01

    This paper reviews the observations of gamma-ray emission made from the OSO-7 satellite in connection with two solar flares in early August 1972. The details of the measurements and a preliminary interpretation of some of the observed features are given. (U.S.)

  12. New Possibilities of Positron-Emission Tomography

    Science.gov (United States)

    Volobuev, A. N.

    2018-01-01

    The reasons for the emergence of the angular distribution of photons generated as a result of annihilation of an electron and a positron in a positron-emission tomograph are investigated. It is shown that the angular distribution of the radiation intensity (i.e., the probability of photon emission at different angles) is a consequence of the Doppler effect in the center-of-mass reference system of the electron and the positron. In the reference frame attached to the electron, the angular distribution of the number of emitted photons does not exists but is replaced by the Doppler shift of the frequency of photons. The results obtained in this study make it possible to extend the potentialities of the positron-emission tomograph in the diagnostics of diseases and to obtain additional mechanical characteristics of human tissues, such as density and viscosity.

  13. Activity and gamma-ray emission standards

    International Nuclear Information System (INIS)

    Debertin, K.

    1983-01-01

    The standards made available by PTB are standards defined with regard to their activity A. If standard and measuring sample do not contain the same nuclide, the comparison with the standard is made via the emission rate R of the photons of a given energy. For this comparison, the value recommended by PTB for PTB standards should be used, as this value in many cases has been derived by emission rate measurements on specimens whose activity has been directly correlated with the activity of the standards released. (orig./DG) [de

  14. Attenuation correction using simultaneous emission - transmission tomography

    International Nuclear Information System (INIS)

    Ljubenov, V.; Marinkovic, P.

    1998-01-01

    In order to reduce degrading influence of attenuation on SPECT image quality, possibility for correction, based on simultaneous emission / transmission measurements, is discussed. Numerical photon transport simulations through the phantom and acquisition of of tomographic projections are performed by using Monte Carlo code MCNP-4A. Amount of contamination in transmission data due to photon Compton scattering for emission energy window is specially analyzed and appropriate spatial depending 'noise / signal' factors for three different external sources, applied with Tc-99m, are determined (author)

  15. A scanner for single photon emission tomography

    International Nuclear Information System (INIS)

    Smith, D.B.; Cumpstey, D.E.; Evans, N.T.S.; Coleman, J.D.; Ettinger, K.V.; Mallard, J.R.

    1982-01-01

    The technique of single photon ECT has now been available for some eighteen years, but has yet still to be exploited fully. The difficulties of doing this lie in the need for gathering data of sufficiently good statistical accuracy in a reasonable counting time, in the uniformity of detector sensitivity, and in the means for correcting the image satisfactorily for photon attenuation within the body. The relative ease with which a general purpose gamma camera can be adapted to give rotation around the patient makes this an attractive practical approach to the problem. However, the sensitivity of gamma cameras over their field of view is by no means uniform, and their sensitivity is less good than that of purpose-designed scanners when no more than about ten sections through the body are required. There is therefore a need to assess the clinical usefulness of a whole body tomographic scanner of high sensitivity and uniformity. Such a machine is the Aberdeen Section Scanner Mark II described

  16. Fermi Discovery of Gamma-Ray Emission from NGC 1275

    Energy Technology Data Exchange (ETDEWEB)

    Abdo, Aous A.; /Naval Research Lab, Wash., D.C.; Ackermann, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Ajello, M.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Asano, K.; /Tokyo Inst. Tech.; Baldini, L.; /INFN, Pisa; Ballet, J.; /DAPNIA, Saclay; Barbiellini, Guido; /INFN, Trieste /Trieste U.; Bastieri, Denis; /INFN, Padua /Padua U.; Baughman, B.M.; /Ohio State U.; Bechtol, K.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bellazzini, R.; /INFN, Pisa; Blandford, R.D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bloom, Elliott D.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bonamente, E.; /INFN, Perugia /Perugia U.; Borgland, A.W.; /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept.; Bregeon, J.; /INFN, Pisa; Brez, A.; /INFN, Pisa; Brigida, M.; /Bari U. /INFN, Bari; Bruel, P.; /Ecole Polytechnique; Burnett, Thompson H.; /Washington U., Seattle; Caliandro, G.A.; /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /IASF, Milan /IASF, Milan /DAPNIA, Saclay /ASDC, Frascati /INFN, Perugia /Perugia U. /SISSA, Trieste /George Mason U. /Naval Research Lab, Wash., D.C. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Perugia /Perugia U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Montpellier U. /ASDC, Frascati /Sonoma State U. /Stockholm U., OKC /Royal Inst. Tech., Stockholm /Stockholm U. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Naval Research Lab, Wash., D.C. /INFN, Trieste /Bari U. /INFN, Bari /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /NASA, Goddard /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /CENBG, Gradignan /CENBG, Gradignan /Montpellier U. /Bari U. /INFN, Bari /Naval Research Lab, Wash., D.C. /Stanford U., HEPL /KIPAC, Menlo Park /Stanford U., Phys. Dept. /INFN, Trieste /Hiroshima U.; /more authors..

    2009-05-15

    We report the discovery of high-energy (E > 100 MeV) {gamma}-ray emission from NGC 1275, a giant elliptical galaxy lying at the center of the Perseus cluster of galaxies, based on observations made with the Large Area Telescope (LAT) of the Fermi Gamma-ray Space Telescope. The positional center of the {gamma}-ray source is only {approx}3{prime} away from the NGC 1275 nucleus, well within the 95% LAT error circle of {approx}5{prime}. The spatial distribution of {gamma}-ray photons is consistent with a point source. The average flux and power-law photon index measured with the LAT from 2008 August 4 to 2008 December 5 are F{sub {gamma}} = (2.10 {+-} 0.23) x 10{sup -7} ph (>100 MeV) cm{sup -2} s{sup -1} and {Gamma} = 2.17 {+-} 0.05, respectively. The measurements are statistically consistent with constant flux during the four-month LAT observing period. Previous EGRET observations gave an upper limit of F{sub {gamma}} < 3.72 x 10{sup -8} ph (>100 MeV) cm{sup -2} s{sup -1} to the {gamma}-ray flux from NGC 1275. This indicates that the source is variable on timescales of years to decades, and therefore restricts the fraction of emission that can be produced in extended regions of the galaxy cluster. Contemporaneous and historical radio observations are also reported. The broadband spectrum of NGC 1275 is modeled with a simple one-zone synchrotron/synchrotron self-Compton model and a model with a decelerating jet flow.

  17. The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in resectable pancreatic cancer.

    Science.gov (United States)

    Crippa, Stefano; Salgarello, Matteo; Laiti, Silvia; Partelli, Stefano; Castelli, Paola; Spinelli, Antonello E; Tamburrino, Domenico; Zamboni, Giuseppe; Falconi, Massimo

    2014-08-01

    The role of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in pancreatic ductal adenocarcinoma is debated. We retrospectively assessed the value of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in addition to conventional imaging as a staging modality in pancreatic cancer. (18)Fluoro-deoxyglucose positron emission tomography/computed tomography was performed in 72 patients with resectable pancreatic carcinoma after multi-detector computed tomography positron emission tomography was considered positive for a maximum standardized uptake value >3. Overall, 21% of patients had a maximum standardized uptake value ≤ 3, and 60% of those had undergone neoadjuvant treatment (P=0.0001). Furthermore, 11% of patients were spared unwarranted surgery since positron emission tomography/computed tomography detected metastatic disease. All liver metastases were subsequently identified with contrast-enhanced ultrasound. Sensitivity and specificity of positron emission tomography/computed tomography for distant metastases were 78% and 100%. The median CA19.9 concentration was 48.8 U/mL for the entire cohort and 292 U/mL for metastatic patients (P=0.112). The widespread application of (18)fluoro-deoxyglucose positron emission tomography/computed tomography in patients with resectable pancreatic carcinoma seems not justified. It should be considered in selected patients at higher risk of metastatic disease (i.e. CA19.9>200 U/mL) after undergoing other imaging tests. Neoadjuvant treatment is significantly associated with low metabolic activity, limiting the value of positron emission tomography in this setting. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  18. Applications of multi-pinhole gamma camera collimation to tomography and image enhancement

    International Nuclear Information System (INIS)

    Simpson, D.R.

    1981-01-01

    Recently, multi-pinhole gamma camera collimation has been introduced in the field of emission tomography. This collimation process simultaneously produces several images covering a limited angular range, which may then be recombined to obtain tomographic slices of the object imaged. This study has investigated a possible method for improving the images obtained by this technique by two multi-pinhole views taken 90 0 apart. During the course of this work, multi-pinhole collimation was also applied to in vivo imaging of the disintegration of tablets. Collimmators were designed and built both for tomography and imaging tablet disintegration, and computer programs were written to reconstruct the images by simple backprojection and by filtered backprojection. The use of multi-pinhole collimators to image the disintegration of tablets in vivo was clearly demonstrated. Phantom tests done in vitro were capable of imaging defects as small as 5 mm 2 , while images made with real tablets both in vitro and in vivo readily showed the onset and progress of the tablet disintegration. Further experiments are planned using this technique to measure gastric emptying times disintegration times of various tablet formulations. Limitations of multi-pinhole technique included problems such as limited ranges of viewing and artifacts introduced due to incomplete sampling

  19. Design optimization of high speed gamma-ray tomography

    International Nuclear Information System (INIS)

    Maad, Rachid

    2009-01-01

    This thesis concerns research and development of efficient gamma-ray systems for high speed tomographic imaging of hydrocarbon flow dynamics with a particular focus on gas liquid imaging. The Bergen HSGT (High Speed Gamma-ray Tomograph) based on instant imaging with a fixed source-detector geometry setup, has been thoroughly characterized with a variety of image reconstruction algorithms and flow conditions. Experiments in flow loops have been carried out for reliable characterization and error analysis, static flow phantoms have been applied for the majority of experiments to provide accurate imaging references. A semi-empirical model has been developed for estimation of the contribution of scattered radiation to each HSGT detector and further for correction of this contribution prior to data reconstruction. The Bergen FGGT (Flexible Geometry Gamma-ray Tomograph) has been further developed, particularly on the software side. The system emulates any fan beam tomography. Based on user input of geometry and other conditions, the new software perform scanning, data acquisition and storage, and also weight matrix calculation and image reconstruction with the desired method. The FGGT has been used for experiments supporting those carried out with the HSGT, and in addition for research on other fan beam geometries suitable for hydrocarbon flow imaging applications. An instant no-scanning tomograph like the HSGT has no flexibility with respect to change of geometry, which usually is necessary when applying the tomograph for a new application. A computer controlled FGGT has been designed and built at the UoB. The software developed for the FGGT controls the scanning procedure, the data acquisition, calculates the weight matrix necessary for the image reconstruction, reconstructs the image using standard reconstruction algorithms, and calculates the error of the reconstructed image. The performance of the geometry has been investigated using a 100 mCi 241 Am disk source, a

  20. 77 FR 21783 - Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography...

    Science.gov (United States)

    2012-04-11

    ...] Guidance on Media Fills for Validation of Aseptic Preparations for Positron Emission Tomography Drugs... Aseptic Preparations for Positron Emission Tomography (PET) Drugs.'' This guidance is intended to help... Preparations for Positron Emission Tomography (PET) Drugs.'' Most PET drugs are designed for parenteral...

  1. Two-quantum Doppler-free induced gamma emission

    International Nuclear Information System (INIS)

    Zadernovsky, A.A.

    1999-01-01

    Reported here is a theoretical study of an alternative way to remove the pernicious influence of chaotic motion of free nuclei by means of external ignition of two-quantum IGE process in counter-propagating intense photon beams. The performed analysis reveals the main advantages and drawbacks of this method. The following conclusions are underlined: 1. in contrast to single-quantum emission in an ensemble of nuclei with Doppler-broadened gain line, this method involves all nuclei regardless of there individual velocities; 2. a specific dynamic distributed feedback is in this case established in absence of any reflecting structures; 3. because of non-linearity of the feedback, with a coefficient proportional to the photon flux density of the igniting beam, the excitation of nuclei is released in an avalanche-like manner, which result in emission of a giant pulse of gamma quanta; 4. at present, the implementation of such a process is impeded by the absence of a source of igniting gamma quanta, with the sufficient photon flux density. Therefore the advantage of the propose technique may manifests themselves only in designing a final stage of a source of gamma quanta (e.g., in X-ray or gamma-ray laser, relativistic undulator, free electron laser, etc.) for production of short giant pulse of coherent gamma photons. (author)

  2. Use of positron emission tomography in colorectal cancer

    International Nuclear Information System (INIS)

    Gonzalez E, Patricio; Jofre E, Josefina; Massardo V, Teresa; Humeres, Pamela; Canessa G, Jose; Sierralta C, Paulina

    2002-01-01

    The value of PET (Positron Emission Tomography) in colorectal cancer is presented. PET is a novel technique that uses F-18-FDG (fluorodeoxiglucose) to assess glucose metabolism by whole body imaging. It has been demonstrated that malignant cells have both increase of glucose uptake and utilization. In colorectal cancer, PET is indicated for staging, assess recurrence, liver metastasis and treatment follow-up. PET is more sensitive and specific than CT (Computed Tomography) and is cost effective. In 30% of cases PET may change patient management, avoiding unnecessary procedures (au)

  3. Single photon emission computed tomography in children with idiopathic seizures

    International Nuclear Information System (INIS)

    Hara, Masafumi; Takahashi, Mutsumasa; Kojima, Akihiro; Shimomura, Osamu; Kinoshita, Rumi; Tomiguchi, Seiji; Taku, Keiichi; Miike, Teruhisa

    1991-01-01

    Single photon emission computed tomography (SPECT) with N-isoprophyl-p [ 123 I]-iodoamphetamine (IMP), X-ray computed tomography (X-CT), and magnetic resonance imaging (MRI) were performed in 20 children with idiopathic seizures. In children with idiopathic seizures, SPECT could detect the abnormal sites at the highest rate (45%) compared with CT (10%) and MRI (12%), but the abnormal sites on SPECT correlated poorly with the foci on electroencephalograph (EEG). Idiopathic epilepsy with hypoperfusion on SPECT was refractory to treatment and was frequently associated with mental and/or developmental retardation. Perfusion defects on SPECT scans probably affect the development and maturation of the brain in children. (author)

  4. Positron emission tomography of FDG in schizophrenia

    International Nuclear Information System (INIS)

    Sargent, T. III; Kusubov, N.

    1986-01-01

    The use of the Donner dynamic positron emission tomograph to study fluorodeoxyglucose labelled 18 F uptake in the brain of six patients with schizophrenia is reported. The glucose metabolic rate and the local cerebral metabolic rate were calculated. The dynamic brain uptake data and the blood input function were used to calculate rate constants by an iterative least squares fitting program for all regions of interest chosen in the brain. Although the number of patients was small, differences in k3 were statistically significant in several brain regions compared with normal controls

  5. Imaging phase holdup distribution of three phase flow systems using dual source gamma ray tomography

    International Nuclear Information System (INIS)

    Varma, Rajneesh; Al-Dahhan, Muthanna; O'Sullivan, Joseph

    2008-01-01

    Full text: Multiphase reaction and process systems are used in abundance in the chemical and biochemical industry. Tomography has been successfully employed to visualize the hydrodynamics of multiphase systems. Most of the tomography methods (gamma ray, x-ray and electrical capacitance and resistance) have been successfully implemented for two phase dynamic systems. However, a significant number of chemical and biochemical systems consists of dynamic three phases. Research effort directed towards the development of tomography techniques to image such dynamic system has met with partial successes for specific systems with applicability to limited operating conditions. A dual source tomography scanner has been developed that uses the 661 keV and 1332 keV photo peaks from the 137 Cs and 60 Co for imaging three phase systems. A new approach has been developed and applied that uses the polyenergetic Alternating Minimization (A-M) algorithm, developed by O'Sullivan and Benac (2007), for imaging the holdup distribution in three phases' dynamic systems. The new approach avoids the traditional post image processing approach used to determine the holdup distribution where the attenuation images of the mixed flow obtained from gamma ray photons of two different energies are used to determine the holdup of three phases. In this approach the holdup images are directly reconstructed from the gamma ray transmission data. The dual source gamma ray tomography scanner and the algorithm were validated using a three phase phantom. Based in the validation, three phase holdup studies we carried out in slurry bubble column containing gas liquid and solid phases in a dynamic state using the dual energy gamma ray tomography. The key results of the holdup distribution studies in the slurry bubble column along with the validation of the dual source gamma ray tomography system would be presented and discussed

  6. Diagnostic utility of fluorodeoxyglucose positron emission tomography/computed tomography in pyrexia of unknown origin

    International Nuclear Information System (INIS)

    Singh, Nidhi; Kumar, Rakesh; Malhotra, Arun; Bhalla, Ashu Seith; Kumar, Uma; Sood, Rita

    2005-01-01

    The present study was undertaken to evaluate the diagnostic utility of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (F-18 FDG PET/CT) in patients presenting as pyrexia of unknown origin (PUO). Forty-seven patients (31 males and 16 females; mean age of 42.7 ± 19.96 years) presenting as PUO to the Department of Medicine at the All India Institute of Medical Sciences, New Delhi over a period of 2 years underwent F-18 FDG PET/CT. PET ⁄ CT was considered supportive when its results correlated with the final definitive diagnosis. Final diagnosis was made on the basis of combined evaluation of history, clinical findings, investigations, and response to treatment. Thirty-five PET/CT studies (74.5%) were positive. However, only 18 (38.3%) were supportive of the final diagnosis. In three patients (6.4%), PET/CT was considered diagnostic as none of the other investigations including contrast-enhanced computed tomography of chest and abdomen, and directed tissue sampling could lead to the final diagnosis. All these three patients were diagnosed as aortoarteritis. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography is an important emerging modality in the workup of PUO. It supported the final diagnosis in 38% of our patients and was diagnostic in 6.4% of patients. Thus, PET/CT should only be considered as second-line investigation for the diagnostic evaluation of PUO; especially in suspected noninfectious inflammatory disorders

  7. Applications of X-ray Computed Tomography and Emission Computed Tomography

    International Nuclear Information System (INIS)

    Seletchi, Emilia Dana; Sutac, Victor

    2005-01-01

    Computed Tomography is a non-destructive imaging method that allows visualization of internal features within non-transparent objects such as sedimentary rocks. Filtering techniques have been applied to circumvent the artifacts and achieve high-quality images for quantitative analysis. High-resolution X-ray computed tomography (HRXCT) can be used to identify the position of the growth axis in speleothems by detecting subtle changes in calcite density between growth bands. HRXCT imagery reveals the three-dimensional variability of coral banding providing information on coral growth and climate over the past several centuries. The Nuclear Medicine imaging technique uses a radioactive tracer, several radiation detectors, and sophisticated computer technologies to understand the biochemical basis of normal and abnormal functions within the brain. The goal of Emission Computed Tomography (ECT) is to accurately determine the three-dimensional radioactivity distribution resulting from the radiopharmaceutical uptake inside the patient instead of the attenuation coefficient distribution from different tissues as obtained from X-ray Computer Tomography. ECT is a very useful tool for investigating the cognitive functions. Because of the low radiation doses associated with Positron Emission Tomography (PET), this technique has been applied in clinical research, allowing the direct study of human neurological diseases. (authors)

  8. Positron Emission Tomography: Principles, Technology, and Recent Developments

    Science.gov (United States)

    Ziegler, Sibylle I.

    2005-04-01

    Positron emission tomography (PET) is a nuclear medical imaging technique for quantitative measurement of physiologic parameters in vivo (an overview of principles and applications can be found in [P.E. Valk, et al., eds. Positron Emission Tomography. Basic Science and Clinical Practice. 2003, Springer: Heidelberg]), based on the detection of small amounts of posi-tron-emitter-labelled biologic molecules. Various radiotracers are available for neuro-logical, cardiological, and oncological applications in the clinic and in research proto-cols. This overview describes the basic principles, technology, and recent develop-ments in PET, followed by a section on the development of a tomograph with ava-lanche photodiodes dedicated for small animal imaging as an example of efforts in the domain of high resolution tomographs.

  9. Positron emission tomography in the management of cervix cancer patients

    International Nuclear Information System (INIS)

    Bonardel, G.; Gontier, E.; Soret, M.; Dechaud, C.; Fayolle, M.; Foehrenbach, H.; Chargari, C.; Bauduceau, O.

    2009-01-01

    Since its introduction in clinical practice in the 1990 s, positron emission tomography (PET), usually with 18 F-fluoro-2-deoxy-D-glucose ( 18 F-F.D.G.), has become an important imaging modality in patients with cancer. For cervix carcinoma, F.D.G.-PET is significantly more accurate than computed tomography (CT) and is recommended for loco-regional lymph node and extra pelvic staging. The metabolic dimension of the technique provides additional prognostic information. Ongoing studies now concentrate on more advanced clinical applications, such as the planning of radiotherapy, the response evaluation after the induction of therapy, the early detection of recurrence. Technical innovations, such as PET cameras with better spatial resolution and hybrid positron emission tomography/computed tomography (PET-CT), available now on the whole territory, provide both anatomic and metabolic information in the same procedure. From the point of view of biological metabolism, new radiopharmaceutical probes are being developed. Those hold promise for future refinements in this field. This article reviews the current applications of F.D.G.-PET in patients with cervix cancer. (authors)

  10. Polarized Emission from Gamma-Ray Burst Jets

    Directory of Open Access Journals (Sweden)

    Shiho Kobayashi

    2017-11-01

    Full Text Available I review how polarization signals have been discussed in the research field of Gamma-Ray Bursts (GRBs. I mainly discuss two subjects in which polarimetry enables us to study the nature of relativistic jets. (1 Jet breaks: Gamma-ray bursts are produced in ultra-relativistic jets. Due to the relativistic beaming effect, the emission can be modeled in a spherical model at early times. However, as the jet gradually slows down, we begin to see the edge of the jet together with polarized signals at some point. (2 Optical flash: later time afterglow is known to be insensitive to the properties of the original ejecta from the GRB central engine. However, a short-lived, reverse shock emission would enable us to study the nature of of GRB jets. I also briefly discuss the recent detection of optical circular polarization in GRB afterglow.

  11. {sup 134}Cs emission probabilities determination by gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, M.C.M. de, E-mail: candida@cnen.gov.br [Comissão Nacional de Energia Nuclear (DINOR/CNEN), Riode Janeiro, RJ (Brazil); Poledna, R.; Delgado, J.U.; Silva, R.L.; Araujo, M.T.; Silva, C.J. da [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-07-01

    The National Laboratory for Ionizing Radiation Metrology (LNMRI/IRD/CNEN) of Rio de Janeiro performed primary and secondary standardization of different radionuclides reaching satisfactory uncertainties. A solution of {sup 134}Cs radionuclide was purchased from commercial supplier to emission probabilities determination of some of its energies. {sup 134}Cs is a beta gamma emitter with 754 days of half-life. This radionuclide is used as standard in environmental, water and food control. It is also important to germanium detector calibration.The gamma emission probabilities (Pγ) were determined mainly for some energies of the {sup 134}Cs by efficiency curve method and the Pγ absolute uncertainties obtained were below 1% (k=1). (author)

  12. Fluorodeoxyglucose positron emission tomography-computed tomography findings in a case of xanthogranulomatous pyelonephritis

    Science.gov (United States)

    Joshi, Prathamesh; Lele, Vikram; Shah, Hardik

    2013-01-01

    Xanthogranulomatous pyelonephritis (XGNP) is an uncommon condition characterized by chronic suppurative renal inflammation that leads to progressive parenchymal destruction. This condition can clinically present as recurrent urinary tract infections, flank pain, hematuria, and occasionally sepsis, and weight loss. This condition is usually associated with obstructing renal calculus. We present 18-fluorodeoxyglucose positron emission tomography-computed tomography (18-FDG PET/CT) findings in an elderly male suffering from pyrexia and weight loss and suspected urinary tract infection. PET/CT findings in this case lead to diagnosis of XGNP. This diagnosis should be kept in mind while evaluating similar symptoms and PET/CT scan findings. PMID:24019680

  13. Position emission tomography with or without computed tomography in the primary staging of Hodgkin's lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Loft, Annika; Hansen, Mads

    2006-01-01

    BACKGROUND AND OBJECTIVES: In order to receive the most appropriate therapy, patients with Hodgkin's lymphoma (HL) must be accurately stratified into different prognostic staging groups. Computed tomography (CT) plays a pivotal role in the conventional staging. The aim of the present study...... was to investigate the value of positron emission tomography using 2-[18F]fluoro-2-deoxy-D-glucose (FDG-PET) and combined FDG-PET/CT for the staging of HL patients, and the impact on the choice of treatment. DESIGN AND METHODS: Ninety-nine consecutive, prospectively included patients had FDG-PET and CT...

  14. Application of positron emission tomography in the heart

    International Nuclear Information System (INIS)

    Anon.

    1988-01-01

    This report discusses experimental and clinical applications of positron emission tomography to the heart, including measurements of blood flow to the myocardium and studies of metabolism and experimental injury. Most initial clinical studies have concentrated on ischemic heart disease, but the technique also has potential for investigation of cardiomyopathies, studying the neural control of the heart, and evaluating the effects of drugs on cardiac tissues

  15. Contribution of positron emission tomography in pleural disease.

    OpenAIRE

    Duysinx, Bernard; Corhay, Jean-Louis; Larock, Marie-Paule; Withofs, Nadia; Bury, Thierry; Hustinx, Roland; Louis, Renaud

    2010-01-01

    INTRODUCTION: Positron emission tomography (PET) now plays a clear role in oncology, especially in chest tumours. We discuss the value of metabolic imaging in characterising pleural pathology in the light of our own experience and review the literature. BACKGROUND: PET is particularly useful in characterising malignant pleural pathologies and is a factor of prognosis in mesothelioma. Metabolic imaging also provides clinical information for staging lung cancer, in researching the primary tumou...

  16. Simulated annealing image reconstruction for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Sundermann, E; Lemahieu, I; Desmedt, P [Department of Electronics and Information Systems, University of Ghent, St. Pietersnieuwstraat 41, B-9000 Ghent, Belgium (Belgium)

    1994-12-31

    In Positron Emission Tomography (PET) images have to be reconstructed from moisy projection data. The noise on the PET data can be modeled by a Poison distribution. In this paper, we present the results of using the simulated annealing technique to reconstruct PET images. Various parameter settings of the simulated annealing algorithm are discussed and optimized. The reconstructed images are of good quality and high contrast, in comparison to other reconstruction techniques. (authors). 11 refs., 2 figs.

  17. Fluorodeoxyglucose Positron Emission Tomography–Computed Tomography in Disseminated Cryptococcosis

    Science.gov (United States)

    Tripathy, Sarthak; Parida, Girish Kumar; Roy, Shambo Guha; Singhal, Abhinav; Mallick, Saumya Ranjan; Tripathi, Madhavi; Shamim, Shamim Ahmed

    2017-01-01

    Disseminated cryptococcosis without pulmonary involvement is a very rare phenomenon. Patterns of organ involvement in cryptococcosis resemble various other infective conditions as well as malignant conditions on fluorodeoxyglucose positron emission tomography–computed tomography. We present a case of a 43-year-old male patient who had disseminated cryptococcosis. The rarity of the case being noninvolvement of lungs and meninges and resembling more like lymphoma due to the diffuse involvement of the lymph nodes on both sides of the diaphragm. PMID:29142368

  18. A new liquid xenon scintillation detector for positron emission tomography

    International Nuclear Information System (INIS)

    Chepel, V.Yu.

    1993-01-01

    A new positron-sensitive detector of annihilation photons filled with liquid xenon is proposed for positron emission tomography. Simultaneous detection of both liquid xenon scintillation and ionization current produces a time resolution of < 1 ns and a position resolution in the tangential direction of the tomograph ring is ∼ 1 mm and in the radial direction is ∼ 5 mm. The advantages of a tomograph with new detectors are discussed. New algorithms of Compton scattering can be used. (author)

  19. Measurement of brain pH with positron emission tomography

    International Nuclear Information System (INIS)

    Buxton, R.B.; Alpert, N.M.; Ackerman, R.H.; Wechsler, L.R.; Elmaleh, D.R.; Correia, J.A.

    1985-01-01

    With positron emission tomography (PET) it is now possible to measure local brain pH noninvasively in humans. The application of PET to the determination of pH is relatively new, so only a handful of papers on the subject have appeared in print. This chapter reviews the current strategies for measuring brain pH with PET, discuss methodological problems, and present initial results

  20. Simulated annealing image reconstruction for positron emission tomography

    International Nuclear Information System (INIS)

    Sundermann, E.; Lemahieu, I.; Desmedt, P.

    1994-01-01

    In Positron Emission Tomography (PET) images have to be reconstructed from moisy projection data. The noise on the PET data can be modeled by a Poison distribution. In this paper, we present the results of using the simulated annealing technique to reconstruct PET images. Various parameter settings of the simulated annealing algorithm are discussed and optimized. The reconstructed images are of good quality and high contrast, in comparison to other reconstruction techniques. (authors)

  1. Measurement of liver volume by emission computed tomography

    International Nuclear Information System (INIS)

    Kan, M.K.; Hopkins, G.B.

    1979-01-01

    In 22 volunteers without clinical or laboratory evidence of liver disease, liver volume was determined using single-photon emission computed tomography (ECT). This technique provided excellent object contrast between the liver and its surroundings and permitted calculation of liver volume without geometric assumptions about the liver's configuration. Reproducibility of results was satisfactory, with a root-mean-square error of less than 6% between duplicate measurements in 15 individuals. The volume measurements were validated by the use of phantoms

  2. Proceedings of the First International Induced Gamma Emission Workshop

    International Nuclear Information System (INIS)

    Popescu, I.I.; Ur, C.A.

    1999-01-01

    The proceedings of the First International Induced Gamma Emission Workshop held on August 16-20, 1997 in Predeal, Romania contain 40 communications. These are bunched in the following 7 sections: 1. Opening session (8 papers); 2. Theory and Modelling (7 papers); 3. Pump Mechanisms (6 papers); 4. Pump Sources (3 papers); 5. Collective Effects (8 papers); 6. Nuclear Isomers (3 papers); 7. Moessbauer Effect (5 papers)

  3. High-energy emission from gamma-ray bursts

    International Nuclear Information System (INIS)

    Nolan, P.L.; Share, G.H.; Matz, S.; Chupp, E.L.; Forrest, D.J.; Rieger, E.

    1984-01-01

    We discuss broad-band continuum spectroscopy of 17 gamma-ray bursts above 0.3 MeV. The spectra were fitted by 3 trial functions, none of which provided an adequate fit to all the spectra. Most were too hard for a thermal bremsstarhlung function. Harder functional forms, such as thermal synchrotron or power-law, provide better fits for most of the spectra. The strong emission observed above 1 MeV raises some interesting theoretical questions

  4. Fast Neutron Emission Tomography of Used Nuclear Fuel Assemblies

    Science.gov (United States)

    Hausladen, Paul; Iyengar, Anagha; Fabris, Lorenzo; Yang, Jinan; Hu, Jianwei; Blackston, Matthew

    2017-09-01

    Oak Ridge National Laboratory is developing a new capability to perform passive fast neutron emission tomography of spent nuclear fuel assemblies for the purpose of verifying their integrity for international safeguards applications. Most of the world's plutonium is contained in spent nuclear fuel, so it is desirable to detect the diversion of irradiated fuel rods from an assembly prior to its transfer to ``difficult to access'' storage, such as a dry cask or permanent repository, where re-verification is practically impossible. Nuclear fuel assemblies typically consist of an array of fuel rods that, depending on exposure in the reactor and consequent ingrowth of 244Cm, are spontaneous sources of as many as 109 neutrons s-1. Neutron emission tomography uses collimation to isolate neutron activity along ``lines of response'' through the assembly and, by combining many collimated views through the object, mathematically extracts the neutron emission from each fuel rod. This technique, by combining the use of fast neutrons -which can penetrate the entire fuel assembly -and computed tomography, is capable of detecting vacancies or substitutions of individual fuel rods. This paper will report on the physics design and component testing of the imaging system. This material is based upon work supported by the U.S. Department of Energy, Office of Defense Nuclear Nonproliferation Research and Development within the National Nuclear Security Administration, under Contract Number DE-AC05-00OR22725.

  5. Materials testing by computerized tomography with neutrons and gamma-rays

    Energy Technology Data Exchange (ETDEWEB)

    El-Ghobary, A M; Bakkoush, F A; Megahid, R M [Reactor and Neutron Physics Department, Nuclear Research Center, A.E.A., Cairo (Egypt)

    1997-12-31

    The method of computerized tomography by fast neutrons and gamma-rays are used for inspecting and testing of materials by non-destructive technique. The transmission technique was applied using narrow collimated beams of reactor neutrons and gamma-ray. The neutron and gamma-rays transmitted through the object inspection were measured by means of a neutron gamma detector with Ne - 213 liquid organic scintillator. The undesired pulses of neutrons or gamma-rays are rejected from the transmitted beam by a discrimination technique based on the difference in the decay part of light pulse produced by recoil electrons or recoil protons. The transmitted neutrons or gamma-rays for different projections used to get the image of the section through the object investigated using the method of filtered back projection (FBP) algorithm. 8 figs.

  6. Positron emission tomography, physical bases and comparaison with other techniques

    International Nuclear Information System (INIS)

    Guermazi, Fadhel; Hamza, F; Amouri, W.; Charfeddine, S.; Kallel, S.; Jardak, I.

    2013-01-01

    Positron emission tomography (PET) is a medical imaging technique that measures the three-dimensional distribution of molecules marked by a positron-emitting particle. PET has grown significantly in clinical fields, particularly in oncology for diagnosis and therapeutic follow purposes. The technical evolutions of this technique are fast. Among the technical improvements, is the coupling of the PET scan with computed tomography (CT). PET is obtained by intravenous injection of a radioactive tracer. The marker is usually fluorine ( 18 F) embedded in a glucose molecule forming the 18-fluorodeoxyglucose (FDG-18). This tracer, similar to glucose, binds to tissues that consume large quantities of the sugar such cancerous tissue, cardiac muscle or brain. Detection using scintillation crystals (BGO, LSO, LYSO) suitable for high energy (511keV) recognizes the lines of the gamma photons originating from the annihilation of a positron with an electron. The electronics of detection or coincidence circuit is based on two criteria: a time window, of about 6 to 15 ns, and an energy window. This system measures the true coincidences that correspond to the detection of two photons of 511 kV from the same annihilation. Most PET devices are constituted by a series of elementary detectors distributed annularly around the patient. Each detector comprises a scintillation crystal matrix coupled to a finite number (4 or 6) of photomultipliers. The electronic circuit, or the coincidence circuit, determines the projection point of annihilation by means of two elementary detectors. The processing of such information must be extremely fast, considering the count rates encountered in practice. The information measured by the coincidence circuit is then positioned in a matrix or sinogram, which contains a set of elements of a projection section of the object. Images are obtained by tomographic reconstruction by powerful computer stations equipped with a software tools allowing the analysis and

  7. Fluorodeoxyglucose-positron emission tomography/computed tomography imaging features of colloid adenocarcinoma of the lung: a case report.

    Science.gov (United States)

    Wang, ZhenGuang; Yu, MingMing; Chen, YueHua; Kong, Yan

    2017-07-27

    Colloid adenocarcinoma of the lung is a rare subtype of variants of invasive adenocarcinomas. We report the appearance of this unusual entity on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography. A 60-year-old man of Chinese Han nationality coughed with a little white sputum for 1 month. Chest computed tomography showed multiple bilateral subpleural nodules and plaques accompanied by air bronchograms, which were most concentrated in the lower lobe of his right lung. Positron emission tomography indicated increased radioactivity uptake with a maximum standardized uptake value of 3.5. Positron emission tomography/computed tomography showed a soft tissue density lesion in his left adrenal gland with a maximum standardized uptake value of 4.1. The positron emission tomography/computed tomography appearance suggested a primary colloid adenocarcinoma in the lower lobe of his right lung accompanied by intrapulmonary and left adrenal gland metastases. The diagnostic rate of colloid adenocarcinoma can be increased by combining the anatomic and metabolic information of lesions. The advantage of positron emission tomography/computed tomography in the diagnosis of colloid adenocarcinoma, as with other cancers, is the ability to locate extrapulmonary disease, facilitating clinical staging.

  8. Imaging of the dopaminergic neurotransmission system using single-photon emission tomography and positron emission tomography in patients with parkinsonism

    International Nuclear Information System (INIS)

    Booij, J.; Tissingh, G.; Winogrodzka, A.; Royen, E.A. van

    1999-01-01

    Parkinsonism is a feature of a number of neurodegenerative diseases, including Parkinson's disease, multiple system atrophy and progressive supranuclear palsy. The results of post-mortem studies point to dysfunction of the dopaminergic neurotransmitter system in patients with parkinsonism. Nowadays, by using single-photon emission tomography (SPET) and positron emission tomography (PET) it is possible to visualise both the nigrostriatal dopaminergic neurons and the striatal dopamine D 2 receptors in vivo. Consequently, SPET and PET imaging of elements of the dopaminergic system can play an important role in the diagnosis of several parkinsonian syndromes. This review concentrates on findings of SPET and PET studies of the dopaminergic neurotransmitter system in various parkinsonian syndromes. (orig.)

  9. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  10. Evaluation of dosimetric techniques in positrons emission tomography and computerized tomography (PET/CT)

    International Nuclear Information System (INIS)

    Pinto, Gabriella Montezano

    2014-01-01

    Among diagnostic techniques PET/CT is one of those with the highest dose delivery to the patient as a cause of external exposure to X-rays, and the use of a radiopharmaceutical that results in a high energy gamma emission. The dosimetry of these two components becomes important in order to optimize and justify the technique. Various dosimetric techniques are found in literature without a consensus of the best to use. With the advances in technological and consequent equipment configuration changes, upgrades and variation in methodologies, particularly in computed tomography, a standardization of these techniques is required. Previous studies show that CT is responsible for 70 % of the dose delivered to the patient in PET/CT examinations. Thus, many researchers have been focused on CT dose optimization protocols studies. This work analyzes the doses involved in a PET/CT oncology protocol by using an Alderson female anthropomorphic phantom in a public hospital of Rio de Janeiro city. The dose estimate for PET examination resulting from the use of 18 F - FDG radiopharmaceutical was conducted through dose factors published in ICRP 106; the dose for CT was estimated and compared by calculation of the absorbed doses to patients according to four methods: thermoluminescent dosimetry (TL0100) distributed in critical organs of the Alderson phantom; measurements of CTOI according to AAPM number 96; correction factor for effective diameter SSOE (AAPM Number 204); and simulation by ImPACT program For CT, the results in terms of effective dose presented (TLO, CTOI and ImPACT) ± 5 % maximum variations between methodologies. Considering medium absorbed dose (TLO, SSOE and ImPACT) the results differed in ± 7 % from each other. These findings demonstrate that parameters provided by the manufacturer on the console can be used to have a primary approach of both, absorbed and effective doses to the patient since that a quality assurance program of these parameters are adopted in

  11. Stimulated Emission Computed Tomography (NSECT) images enhancement using a linear filter in the frequency domain

    Energy Technology Data Exchange (ETDEWEB)

    Viana, Rodrigo S.S.; Tardelli, Tiago C.; Yoriyaz, Helio, E-mail: hyoriyaz@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Jackowski, Marcel P., E-mail: mjack@ime.usp.b [University of Sao Paulo (USP), SP (Brazil). Dept. of Computer Science

    2011-07-01

    In recent years, a new technique for in vivo spectrographic imaging of stable isotopes was presented as Neutron Stimulated Emission Computed Tomography (NSECT). In this technique, a fast neutrons beam stimulates stable nuclei in a sample, which emit characteristic gamma radiation. The photon energy is unique and is used to identify the emitting nuclei. The emitted gamma energy spectra can be used for reconstruction of the target tissue image and for determination of the tissue elemental composition. Due to the stochastic nature of photon emission process by irradiated tissue, one of the most suitable algorithms for tomographic reconstruction is the Expectation-Maximization (E-M) algorithm, once on its formulation are considered simultaneously the probabilities of photons emission and detection. However, a disadvantage of this algorithm is the introduction of noise in the reconstructed image as the number of iterations increases. This increase can be caused either by features of the algorithm itself or by the low sampling rate of projections used for tomographic reconstruction. In this work, a linear filter in the frequency domain was used in order to improve the quality of the reconstructed images. (author)

  12. Stimulated Emission Computed Tomography (NSECT) images enhancement using a linear filter in the frequency domain

    International Nuclear Information System (INIS)

    Viana, Rodrigo S.S.; Tardelli, Tiago C.; Yoriyaz, Helio; Jackowski, Marcel P.

    2011-01-01

    In recent years, a new technique for in vivo spectrographic imaging of stable isotopes was presented as Neutron Stimulated Emission Computed Tomography (NSECT). In this technique, a fast neutrons beam stimulates stable nuclei in a sample, which emit characteristic gamma radiation. The photon energy is unique and is used to identify the emitting nuclei. The emitted gamma energy spectra can be used for reconstruction of the target tissue image and for determination of the tissue elemental composition. Due to the stochastic nature of photon emission process by irradiated tissue, one of the most suitable algorithms for tomographic reconstruction is the Expectation-Maximization (E-M) algorithm, once on its formulation are considered simultaneously the probabilities of photons emission and detection. However, a disadvantage of this algorithm is the introduction of noise in the reconstructed image as the number of iterations increases. This increase can be caused either by features of the algorithm itself or by the low sampling rate of projections used for tomographic reconstruction. In this work, a linear filter in the frequency domain was used in order to improve the quality of the reconstructed images. (author)

  13. Limits for an inverse bremsstrahlung origin of the diffuse Galactic soft gamma-ray emission

    DEFF Research Database (Denmark)

    Pohl, M.

    1998-01-01

    origin of the soft Galactic gamma-ray continuum through inverse bremsstrahlung. A flux of low-energy cosmic rays strong enough to produce the observed spectrum of gamma-rays implies substantial gamma-ray emission at a few MeV through nuclear de-excitation. It is shown that the existing limits on excess 3......-7 MeV emission from the Galactic plane, in concert with the constraints from pi(0)-decay gamma-ray emission at higher energies, are in serious conflict with an inverse bremsstrahlung origin of the Galactic soft gamma-ray emission for any physically plausible low-energy cosmic ray spectrum. While...

  14. Gamma-emissions of some meteorites and terrestrial rocks. Evaluation of lunar soil radioactivity

    International Nuclear Information System (INIS)

    Nordemann, D.

    1966-01-01

    The gamma-emissions of some terrestrial rocks and of the following meteorites: Bogou, Eagle-Station, Granes, and Dosso were studied by quantitative low background gamma spectrometry. These measurements and their interpretation lead to the evaluation of the possible gamma-emissions of several models of lunar soils. (author) [fr

  15. The Prompt and High Energy Emission of Gamma Ray Bursts

    International Nuclear Information System (INIS)

    Meszaros, P.

    2009-01-01

    I discuss some recent developments concerning the prompt emission of gamma-ray bursts, in particular the jet properties and radiation mechanisms, as exemplified by the naked-eye burst GRB 080319b, and the prompt X-ray emission of XRB080109/SN2008d, where the progenitor has, for the first time, been shown to contribute to the prompt emission. I discuss then some recent theoretical calculations of the GeV/TeV spectrum of GRB in the context of both leptonic SSC models and hadronic models. The recent observations by the Fermi satellite of GRB 080916C are then reviewed, and their implications for such models are discussed, together with its interesting determination of a bulk Lorentz factor, and the highest lower limit on the quantum gravity energy scale so far.

  16. Dark matter properties implied by gamma ray interstellar emission models

    Energy Technology Data Exchange (ETDEWEB)

    Balázs, Csaba; Li, Tong, E-mail: csaba.balazs@monash.edu, E-mail: tong.li@monash.edu [ARC Centre of Excellence for Particle Physics at the Tera-scale, School of Physics and Astronomy, Monash University, Melbourne, Victoria 3800 (Australia)

    2017-02-01

    We infer dark matter properties from gamma ray residuals extracted using eight different interstellar emission scenarios proposed by the Fermi-LAT Collaboration to explain the Galactic Center gamma ray excess. Adopting the most plausible simplified ansatz, we assume that the dark matter particle is a Majorana fermion interacting with standard fermions via a scalar mediator. To trivially respect flavor constraints, we only couple the mediator to third generation fermions. Using this theoretical hypothesis, and the Fermi residuals, we calculate Bayesian evidences, including Fermi-LAT exclusion limits from 15 dwarf spheroidal galaxies as well. Our evidence ratios single out one of the Fermi scenarios as most compatible with the simplified dark matter model. In this scenario the dark matter (mediator) mass is in the 25-200 (1-1000) GeV range and its annihilation is dominated by bottom quark final state. Our conclusion is that the properties of dark matter extracted from gamma ray data are highly sensitive to the modeling of the interstellar emission.

  17. Imaging prostate cancer: an update on positron emission tomography and magnetic resonance imaging

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Turkbey, Baris; Choyke, Peter

    2010-01-01

    , and molecular imaging information. Developments in imaging technologies, specifically magnetic resonance imaging (MRI) and positron emission tomography (PET)/computed tomography (CT), have improved the detection rate of prostate cancer. MRI has improved lesion detection and local staging. Furthermore, MRI...

  18. Single photon emission computed tomography in AIDS dementia complex

    International Nuclear Information System (INIS)

    Pohl, P.; Vogl, G.; Fill, H.; Roessler, H.Z.; Zangerle, R.; Gerstenbrand, F.

    1988-01-01

    Single photon emission computed tomography (SPECT) studies were performed in AIDS dementia complex using IMP in 12 patients (and HM-PAO in four of these same patients). In all patients, SPECT revealed either multiple or focal uptake defects, the latter corresponding with focal signs or symptoms in all but one case. Computerized tomography showed a diffuse cerebral atrophy in eight of 12 patients, magnetic resonance imaging exhibited changes like atrophy and/or leukoencephalopathy in two of five cases. Our data indicate that both disturbance of cerebral amine metabolism and alteration of local perfusion share in the pathogenesis of AIDS dementia complex. SPECT is an important aid in the diagnosis of AIDS dementia complex and contributes to the understanding of the pathophysiological mechanisms of this disorder

  19. Diagnosis and evaluation of gastric cancer by positron emission tomography

    Science.gov (United States)

    Wu, Chen-Xi; Zhu, Zhao-Hui

    2014-01-01

    Gastric cancer is the second leading cause of cancer mortality worldwide. The diagnosis of gastric cancer has been significantly improved with the broad availability of gastrointestinal endoscopy. Effective technologies for accurate staging and quantitative evaluation are still in demand to merit reasonable treatment and better prognosis for the patients presented with advanced disease. Preoperative staging using conventional imaging tools, such as computed tomography (CT) and endoscopic ultrasonography, is inadequate. Positron emission tomography (PET), using 18F-fluorodeoxyglucose (FDG) as a tracer and integrating CT for anatomic localization, holds a promise to detect unsuspected metastasis and has been extensively used in a variety of malignancies. However, the value of FDG PET/CT in diagnosis and evaluation of gastric cancer is still controversial. This article reviews the current literature in diagnosis, staging, response evaluation, and relapse monitoring of gastric cancer, and discusses the current understanding, improvement, and future prospects in this area. PMID:24782610

  20. Positron emission tomography (PET) for oncologic applications in oral region

    International Nuclear Information System (INIS)

    Shozushima, Masanori; Terasaki, Kazunori

    2004-01-01

    A rapidly emerging clinical application of positron emission tomography (PET) is the detection of cancer with radionuclide tracer, because it provides information unavailable by ultrasound, computed tomography or magnetic resonance imaging. The most commonly used radiotracer for PET oncologic imaging is fluorine-18-labeled fluorodeoxyglucose ( 18 F-FDG). Early studies show PET has potential value in viewing the region of the tumor, detecting, staging, grading, monitoring response to anticancer therapy, and differentiating recurrent or residual disease from post treatment changes. However, limitations of FDG-PET in the head and neck region, namely, physiological FDG uptake in the salivary glands and palatine tonsils, have been reported, increasing the false-positive rates in image interpretation. This review was designed to address these distinctions of oral cancer PET imaging: specialization of PET equipment, cancer cell metabolism, proliferation and tracers, clinical diagnosis of oral cancer with PET, pitfalls in oncologic diagnosis with FDG-PET imaging. (author)

  1. Positron emission tomography in a national research centre

    International Nuclear Information System (INIS)

    Weinreich, R.

    1989-01-01

    The example of the Paul Scherrer Institute shows that positron emission tomography can be implanted successfully as spin-off into an appropriate environment. The adaption to the existing irradiation facilities of the technique of production of the short-lived positron emitters is complex. However, the basic necessities of a tomography programme can be covered. Moreover, the relatively high energy of the institute's injector cyclotron allows additional production of rare-used longer-lived positron emitters. The scanner exceeded the guaranteed specifications. With respect to the somewhat lower availability of beam time compared to a usual baby cyclotron, the research programme must not be very patient-intense. A strong participation of the pharmaceutical industry has directed research priorities into the pharmacological area. (orig.) [de

  2. Imaging local brain function with emission computed tomography

    International Nuclear Information System (INIS)

    Kuhl, D.E.

    1984-01-01

    Positron emission tomography (PET) using 18 F-fluorodeoxyglucose (FDG) was used to map local cerebral glucose utilization in the study of local cerebral function. This information differs fundamentally from structural assessment by means of computed tomography (CT). In normal human volunteers, the FDG scan was used to determine the cerebral metabolic response to conrolled sensory stimulation and the effects of aging. Cerebral metabolic patterns are distinctive among depressed and demented elderly patients. The FDG scan appears normal in the depressed patient, studded with multiple metabolic defects in patients with multiple infarct dementia, and in the patients with Alzheimer disease, metabolism is particularly reduced in the parietal cortex, but only slightly reduced in the caudate and thalamus. The interictal FDG scan effectively detects hypometabolic brain zones that are sites of onset for seizures in patients with partial epilepsy, even though these zones usually appear normal on CT scans. The future prospects of PET are discussed

  3. Inverse compton emission of gamma rays near the pulsar surface

    International Nuclear Information System (INIS)

    Morini, M.

    1981-01-01

    The physical conditions near pulsar surface that might give rise to gamma ray emission from Crab and Vela pulsars are not yet well understood. Here I suggest that, in the context of the vacuum discharge mechanism proposed by Ruderman and Sutherland (1975), gamma rays are produced by inverse Compton scattering of secondary electrons with the thermal radiation of the star surface as well as for curvature and synchotron radiation. It is found that inverse Compton scattering is relevant if the neutron star surface temperature is greater than 10 6 K or of the polar cap temperature is of the order of 5 x 10 6 K. Inverse Compton scattering in anisotropic photon fields and Klein-Nishina regime is here carefully considered. (orig.)

  4. Time resolution in scintillator based detectors for positron emission tomography

    International Nuclear Information System (INIS)

    Gundacker, S.

    2014-01-01

    In the domain of medical photon detectors L(Y)SO scintillators are used for positron emission tomography (PET). The interest for time of flight (TOF) in PET is increasing since measurements have shown that new crystals like L(Y)SO coupled to state of the art photodetectors, e.g. silicon photomultipliers (SiPM), can reach coincidence time resolutions (CTRs) of far below 500ps FWHM. To achieve these goals it is important to study the processe in the whole detection chain, i.e. the high energy particle or gamma interaction in the crystal, the scintillation process itself, the light propagation in the crystal with the light transfer to the photodetector, and the electronic readout. In this thesis time resolution measurements for a PET like system are performed in a coincidence setup utilizing the ultra fast amplifier discriminator NINO. We found that the time-over-threshold energy information provided by NINO shows a degradation in energy resolution for higher SiPM bias voltages. This is a consequence of the increasing dark count rate (DCR) of the SiPM with higher bias voltages together with the exponential decay of the signal. To overcome this problem and to operate the SiPM at its optimum voltage in terms of timing we developed a new electronic board that employs NINO only as a low noise leading edge discriminator together with an analog amplifier which delivers the energy information. With this new electronic board we indeed improved the measured CTR by about 15%. To study the limits of time resolution in more depth we measured the CTR with 2x2x3mm3 LSO:Ce codoped 0.4%Ca crystals coupled to commercially available SiPMs (Hamamatsu S10931-50P MPPC) and achieved a CTR of 108±5ps FWHM at an energy of 511keV. We determined the influence of the data acquisition system and the electronics on the CTR to be 27±2ps FWHM and thus negligible. To quantitatively understand the measured values, we developed a Monte Carlo simulation tool in MATLAB that incorporates the timing

  5. Positron Emission Tomography (PET) and breast cancer in clinical practice

    International Nuclear Information System (INIS)

    Lavayssiere, Robert; Cabee, Anne-Elizabeth; Filmont, Jean-Emmanuel

    2009-01-01

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005

  6. Positron Emission Tomography (PET) and breast cancer in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Lavayssiere, Robert [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France)], E-mail: cab.lav@wanadoo.fr; Cabee, Anne-Elizabeth [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); Centre RMX, 80, avenue Felix Faure, 75105 Paris (France); Filmont, Jean-Emmanuel [Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); American Hospital of Paris, Nuclear Medicine, 63, boulevard Victor Hugo - BP 109, 92202 Neuilly sur Seine Cedex (France)

    2009-01-15

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005].

  7. Contribution of positron emission tomography in pleural disease.

    Science.gov (United States)

    Duysinx, B; Corhay, J-L; Larock, M-P; Withofs, N; Bury, T; Hustinx, R; Louis, R

    2010-10-01

    Positron emission tomography (PET) now plays a clear role in oncology, especially in chest tumours. We discuss the value of metabolic imaging in characterising pleural pathology in the light of our own experience and review the literature. PET is particularly useful in characterising malignant pleural pathologies and is a factor of prognosis in mesothelioma. Metabolic imaging also provides clinical information for staging lung cancer, in researching the primary tumour in metastatic pleurisy and in monitoring chronic or recurrent pleural pathologies. PET should therefore be considered as a useful tool in the diagnosis of liquid or solid pleural pathologies. Copyright © 2010 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  8. Positron emission tomography. Present status and Romanian perspectives

    International Nuclear Information System (INIS)

    Constantinescu, B.; Lungu, V.

    1995-01-01

    Basic principles of the positron emission tomography (PET) are summarised. The main PET methods using short-lived radioisotopes (i.e. 11 C, 13 N, 15 O, 18 F) are briefly reviewed. Three types of particle accelerators for radioisotopes production and medical uses (including radiotherapy), corresponding to the proton energy (E p p p < 200 MeV) are presented. PET imaging equipment and procedures are discussed. Main radiopharmaceuticals based on beta decay for PET studies and their role in medicine is also described. Finally, perspectives for a PET program in Romania (Cyclotron + Radiochemistry + Tomograph ) are discussed. (author)

  9. Kinetic modeling in pre-clinical positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kuntner, Claudia [AIT Austrian Institute of Technology GmbH, Seibersdorf (Austria). Biomedical Systems, Health and Environment Dept.

    2014-07-01

    Pre-clinical positron emission tomography (PET) has evolved in the last few years from pure visualization of radiotracer uptake and distribution towards quantification of the physiological parameters. For reliable and reproducible quantification the kinetic modeling methods used to obtain relevant parameters of radiotracer tissue interaction are important. Here we present different kinetic modeling techniques with a focus on compartmental models including plasma input models and reference tissue input models. The experimental challenges of deriving the plasma input function in rodents and the effect of anesthesia are discussed. Finally, in vivo application of kinetic modeling in various areas of pre-clinical research is presented and compared to human data.

  10. Time-of-Flight Positron Emission Tomography with Radiofrequency Phototube

    International Nuclear Information System (INIS)

    Margaryan, A.; Kakoyan, V.; Knyazyan, S.

    2011-01-01

    In this paper γ-detector, based on the radiofrequency (RF) phototube and recently developed fast and ultrafast scintillators, is considered for Time-of-Flight positron emission tomography applications. Timing characteristics of such a device has been investigated by means of a dedicated Monte Carlo code based on the single photon counting concept. Biexponential timing model for scintillators have been used. The calculations have shown that such a timing model is in a good agreement with recently measured data. The timing resolution of -detectors can be significantly improved by using the RF phototube. (authors)

  11. Low-resource synchronous coincidence processor for positron emission tomography

    International Nuclear Information System (INIS)

    Sportelli, Giancarlo; Belcari, Nicola; Guerra, Pedro; Santos, Andres

    2011-01-01

    We developed a new FPGA-based method for coincidence detection in positron emission tomography. The method requires low device resources and no specific peripherals in order to resolve coincident digital pulses within a time window of a few nanoseconds. This method has been validated with a low-end Xilinx Spartan-3E and provided coincidence resolutions lower than 6 ns. This resolution depends directly on the signal propagation properties of the target device and the maximum available clock frequency, therefore it is expected to improve considerably on higher-end FPGAs.

  12. Functional imaging of the brain with positron emission tomography

    International Nuclear Information System (INIS)

    Alavi, A.; Reivich, M.; Jones, S.C.; Greenberg, J.H.; Wolf, A.P.

    1982-01-01

    An extensive review, with 191 references, of the development and diagnostic use of positron emission tomography (PET) of the brain is presented. An historical overview of functional studies of the brain reviews the use of nitrons oxide, 85 Kr and 133 Xe, [ 14 C]2-deoxyglucose, and [ 18 F]FDG. The [ 18 F]FDG technique allows the investigation of the effects of physiologic stimulation on the brain. Several studies using this technique are reported. The effects of stroke, seizure disorders, aging and dementia, and schizophrenia on cerebral metabolism as demosntrated by PET are explored

  13. Images to visualize the brain. PET: Positron Emission Tomography

    International Nuclear Information System (INIS)

    1992-01-01

    Diagnosis instrument and research tool, Positron Emission Tomography permits advanced technological developments on positron camera, on molecule labelling and principally on very complex 3D image processing. Cyceron Centre in Caen-France works on brain diseases and try to understand the mechanism of observed troubles and to assess the treatment efficiency with PET. Service Hospitalier Frederic Joliot of CEA-France establishes a mapping of cognitive functions in PET as vision areas, anxiety regions, brain organization of language, different attention forms, voluntary actions and motor functions

  14. Gamma-burst emission from neutron-star accretion

    Science.gov (United States)

    Colgate, S. A.; Petschek, A. G.; Sarracino, R.

    1983-01-01

    A model for emission of the hard photons of gamma bursts is presented. The model assumes accretion at nearly the Eddington limited rate onto a neutron star without a magnetic field. Initially soft photons are heated as they are compressed between the accreting matter and the star. A large electric field due to relatively small charge separation is required to drag electrons into the star with the nuclei against the flux of photons leaking out through the accreting matter. The photon number is not increased substantially by Bremsstrahlung or any other process. It is suggested that instability in an accretion disc might provide the infalling matter required.

  15. Neutron-Activated Gamma-Emission: Technology Review

    Science.gov (United States)

    2012-01-01

    in Be9 + α  C12 + n and Be9 + α  3He4 + n. Chadwick (5) made use of the naturally occurring α-emitter polonium - 210 , which decays to lead-206 with...emission, the variation of gamma attenuation with distance and the presence of organic clutter (in food , fertilizer, dirt road, etc.) makes it 8...a neutron source by mixing a radioisotope that emits alpha particles, such as radium or polonium , with a low atomic weight isotope, usually in the

  16. An analysis of true- and false-positive results of vocal fold uptake in positron emission tomography-computed tomography imaging.

    Science.gov (United States)

    Seymour, N; Burkill, G; Harries, M

    2018-03-01

    Positron emission tomography-computed tomography with fluorine-18 fluorodeoxy-D-glucose has a major role in the investigation of head and neck cancers. Fluorine-18 fluorodeoxy-D-glucose is not a tumour-specific tracer and can also accumulate in benign pathology. Therefore, positron emission tomography-computed tomography scan interpretation difficulties are common in the head and neck, which can produce false-positive results. This study aimed to investigate patients detected as having abnormal vocal fold uptake on fluorine-18 fluorodeoxy-D-glucose positron emission tomography-computed tomography. Positron emission tomography-computed tomography scans were identified over a 15-month period where reports contained evidence of unilateral vocal fold uptake or vocal fold pathology. Patients' notes and laryngoscopy results were analysed. Forty-six patients were identified as having abnormal vocal fold uptake on positron emission tomography-computed tomography. Twenty-three patients underwent positron emission tomography-computed tomography and flexible laryngoscopy: 61 per cent of patients had true-positive positron emission tomography-computed tomography scans and 39 per cent had false-positive scan results. Most patients referred to ENT for abnormal findings on positron emission tomography-computed tomography scans had true-positive findings. Asymmetrical fluorine-18 fluorodeoxy-D-glucose uptake should raise suspicion of vocal fold pathology, accepting a false-positive rate of approximately 40 per cent.

  17. Efficacy of 3D-positron emission tomography/computed tomography for upper abdomen.

    Science.gov (United States)

    Murakami, Koji; Nakahara, Tadaki

    2014-04-01

    Recent advancement in computed tomography (CT) enables us to obtain high spatial resolution image and made it possible to construct extensive high-definition three-dimensional (3D) images. But a lack of contrast resolution in CT alone is still remained problem. Meanwhile, as fluorodeoxyglucose-positron emission tomography (PET) can visualize tumors in high contrast, we can create 3D images fusing the accumulation in tumors on PET/CT images. Such images can play the role of a "map of body" which makes it easy to understand the anatomical information before surgery. We also try to evaluate segmental liver function by using PET/CT fusion images. By using (11) C-methionine PET/contrast-enhanced CT, superior image quality compared to single photon emission computed tomography/CT can be obtained. CT, especially with contrast enhancement for obtaining anatomical imaging information plus PET for obtaining functional imaging information is a highly compatible combination, and adding these two types information will further increase clinical usefulness. © 2014 Japanese Society of Hepato-Biliary-Pancreatic Surgery.

  18. Cone beam tomography of the heart using single-photon emission-computed tomography

    International Nuclear Information System (INIS)

    Gullberg, G.T.; Christian, P.E.; Zeng, G.L.; Datz, F.L.; Morgan, H.T.

    1991-01-01

    The authors evaluated cone beam single-photon emission-computed tomography (SPECT) of the heart. A new cone beam reconstruction algorithm was used to reconstruct data collected from short scan acquisitions (of slightly more than 180 degrees) of a detector anteriorally traversing a noncircular orbit. The less than 360 degrees acquisition was used to minimize the attenuation artifacts that result from reconstructing posterior projections of 201T1 emissions from the heart. The algorithm includes a new method for reconstructing truncated projections of background tissue activity that eliminates reconstruction ring artifacts. Phantom and patient results are presented which compare a high-resolution cone beam collimator (50-cm focal length; 6.0-mm full width at half maximum [FWHM] at 10 cm) to a low-energy general purpose (LEGP) parallel hole collimator (8.2-mm FWHM at 10 cm) which is 1.33 times more sensitive. The cone beam tomographic results are free of reconstruction artifacts and show improved spatial and contrast resolution over that obtained with the LEGP parallel hole collimator. The limited angular sampling restrictions and truncation problems associated with cone beam tomography do not deter from obtaining diagnostic information. However, even though these preliminary results are encouraging, a thorough clinical study is still needed to investigate the specificity and sensitivity of cone beam tomography

  19. The metabolism of the human brain studied with positron emission tomography

    International Nuclear Information System (INIS)

    Greitz, T.; Ingvar, D.H.; Widen, L.

    1985-01-01

    This volume presents coverage of the use of positron emission tomography (PET) to study the human brain. The contributors assess new developments in high-resolution positron emission tomography, cyclotrons, radiochemistry, and tracer kinetic models, and explore the use of PET in brain energy metabolism, blood flow, and protein synthesis measurements, receptor analysis, and pH determinations, In addition, they discuss the relevance and applications of positron emission tomography from the perspectives of physiology, neurology, and psychiatry

  20. Clinical applications of positron emission tomography at Montreal Neurological Institute

    International Nuclear Information System (INIS)

    Morgan, P.P.

    1983-01-01

    The Montreal Neurological Institute occupies a leading position in positron emission tomography (PET) of the brain with the help of the following three techological gains: they have acquired a 'Therascan' positron emission tomograph manufactured by Atomic Energy of Canada Ltd.; also, a 'Baby Cyclotron' manufactured by Japan Steel Works Ltd.; and they have written a computer program to display the results in colour. Four short-lived isotopes are used; 11 C, 15 O, 18 F, 13 N. Studies of the oxygen uptake of tumours, their glucose metabolism (as monitored by 18 F labelled 2-fluoro-2-deoxyglucose), and their uptake of therapeutic agents, provide valuable research and diagnostic information. PET is also being used to study epilepsy and cerebrovascular disease

  1. Sensitivity estimation in time-of-flight list-mode positron emission tomography.

    Science.gov (United States)

    Herraiz, J L; Sitek, A

    2015-11-01

    An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

  2. Sensitivity estimation in time-of-flight list-mode positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Herraiz, J. L. [Madrid-MIT M+Visión Consortium, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 and Grupo de Física Nuclear, Departamento de Física Atómica, Molecular y Nuclear, Universidad Complutense de Madrid, CEI Moncloa, Madrid 28040 (Spain); Sitek, A., E-mail: sarkadiu@gmail.com [Center for Advanced Medical Imaging Sciences, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts 02114 (United States)

    2015-11-15

    Purpose: An accurate quantification of the images in positron emission tomography (PET) requires knowing the actual sensitivity at each voxel, which represents the probability that a positron emitted in that voxel is finally detected as a coincidence of two gamma rays in a pair of detectors in the PET scanner. This sensitivity depends on the characteristics of the acquisition, as it is affected by the attenuation of the annihilation gamma rays in the body, and possible variations of the sensitivity of the scanner detectors. In this work, the authors propose a new approach to handle time-of-flight (TOF) list-mode PET data, which allows performing either or both, a self-attenuation correction, and self-normalization correction based on emission data only. Methods: The authors derive the theory using a fully Bayesian statistical model of complete data. The authors perform an initial evaluation of algorithms derived from that theory and proposed in this work using numerical 2D list-mode simulations with different TOF resolutions and total number of detected coincidences. Effects of randoms and scatter are not simulated. Results: The authors found that proposed algorithms successfully correct for unknown attenuation and scanner normalization for simulated 2D list-mode TOF-PET data. Conclusions: A new method is presented that can be used for corrections for attenuation and normalization (sensitivity) using TOF list-mode data.

  3. Acute Calculous Cholecystitis Missed on Computed Tomography and Ultrasound but Diagnosed with Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Carina Mari Aparici

    2016-01-01

    Full Text Available We present a case of a 69-year-old patient who underwent ascending aortic aneurysm repair with aortic valve replacement. On postsurgical day 12, he developed leukocytosis and low-grade fevers. The chest computed tomography (CT showed a periaortic hematoma which represents a postsurgical change from aortic aneurysm repair, and a small pericardial effusion. The abdominal ultrasound showed cholelithiasis without any sign of cholecystitis. Finally, a fluorodeoxyglucose (FDG-positron emission tomography (PET/CT examination was ordered to find the cause of fever of unknown origin, and it showed increased FDG uptake in the gallbladder wall, with no uptake in the lumen. FDG-PET/CT can diagnose acute cholecystitis in patients with nonspecific clinical symptoms and laboratory results.

  4. First image from a combined positron emission tomography and field-cycled MRI system.

    Science.gov (United States)

    Bindseil, Geron A; Gilbert, Kyle M; Scholl, Timothy J; Handler, William B; Chronik, Blaine A

    2011-07-01

    Combining positron emission tomography and MRI modalities typically requires using either conventional MRI with a MR-compatible positron emission tomography system or a modified MR system with conventional positron emission tomography. A feature of field-cycled MRI is that all magnetic fields can be turned off rapidly, enabling the use of conventional positron emission tomography detectors based on photomultiplier tubes. In this demonstration, two photomultiplier tube-based positron emission tomography detectors were integrated with a field-cycled MRI system (0.3 T/4 MHz) by placing them into a 9-cm axial gap. A positron emission tomography-MRI phantom consisting of a triangular arrangement of positron-emitting point sources embedded in an onion was imaged in a repeating interleaved sequence of ∼1 sec MRI then 1 sec positron emission tomography. The first multimodality images from the combined positron emission tomography and field-cycled MRI system show no additional artifacts due to interaction between the systems and demonstrate the potential of this approach to combining positron emission tomography and MRI. Copyright © 2010 Wiley-Liss, Inc.

  5. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Science.gov (United States)

    Sürücü, Erdem; Demir, Yusuf; Dülger, Ahmet C.; Batur, Abdüssamed; Ölmez, Şehmus; Kitapçı, Mehmet T.

    2016-01-01

    A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT) scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG) uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT. PMID:27751978

  6. Prognostic Evaluation of 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Endometrial Cancer

    DEFF Research Database (Denmark)

    Vilstrup, Mie Holm; Jochumsen, Kirsten M; Hess, Søren

    2017-01-01

    .19-8.49) and 1.93 (0.80-4.68), respectively. Whole-body cTLG of greater than or equal to 176.1 g yielded a hazard ratio of 5.70 (1.94-16.78) for OS in a multivariate analysis. CONCLUSIONS: Preoperative SUVmax and cTLG showed potential as independent prognostic markers of OS in patients with primarily high...... and a preoperative F-fluorodeoxyglucose positron emission tomography/computed tomography before curatively intended treatment were included. The scans were evaluated using standard uptake values [maximum standard uptake value (SUVmax) and partial volume corrected (c) mean standardized uptake value (SUVmean...... proportional regression models were used for prognostic evaluation. RESULTS: Eighty-three patients (median age, 69.9 y; range, 26.8-91.1) with primarily high-risk endometrial cancer or suspected high The International Federation of Gynecology and Obstetrics stage were included. Mean follow-up time was 3...

  7. Fasciola Hepatica Mimicking Malignancy on 18F-Fluorodeoxyglucose-Positron Emission Tomography/Computed Tomography

    Directory of Open Access Journals (Sweden)

    Erdem Sürücü

    2016-10-01

    Full Text Available A 48-year-old female with complaints of gastrointestinal symptoms such as abdominal pain, fatigue, vomiting, nausea, and weight loss was diagnosed with neuroendocrine tumor after removal of a 2 mm lesion from the stomach with endoscopic biopsy. Her magnetic resonance imaging that was performed due to on-going symptoms showed multiple linear hypointense lesions in the liver. Positron emission tomography/computed tomography (PET/CT scan was performed for differential diagnosis, which showed high fluorodeoxyglucose (FDG uptake in these lesions. Clinical and laboratory findings revealed the final diagnosis as Fasciola hepatica. The imaging features of this case is presented to aid in differentiating this infectious disease from malignancy and avoid misdiagnosis on FDG-PET/CT.

  8. Positron emission tomography/computed tomography and radioimmunotherapy of prostate cancer

    DEFF Research Database (Denmark)

    Bouchelouche, Kirsten; Capala, Jacek; Oehr, Peter

    2009-01-01

    of a number of diagnostic and therapeutic strategies. J591, a monoclonal antibody, which targets the extracellular domain of prostate-specific membrane antigen, shows promising results. HER2 receptors may also have a potential as target for PET/CT imaging and RIT of advanced prostate cancer. SUMMARY: PET......PURPOSE OF REVIEW: Traditional morphologically based imaging modalities are now being complemented by positron emission tomography (PET)/computed tomography (CT) in prostate cancer. Metastatic prostate cancer is an attractive target for radioimmunotherapy (RIT) as no effective therapies...... are available. This review highlights the most important achievements within the last year in PET/CT and RIT of prostate cancer. RECENT FINDINGS: Conflicting results exist on the use of choline for detection of malignant disease in the prostate gland. The role of PET/CT in N-staging remains to be elucidated...

  9. Fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of primary pulmonary angiosarcomas

    International Nuclear Information System (INIS)

    Krishnamurthy, Arvind; Nayak, Deepika; Ramshankar, Vijayalakshmi; Majhi, Urmila

    2015-01-01

    Angiosarcoma is a malignant vascular tumor that originates from the mesenchymal cells which have undergone angioblastic differentiation. Pulmonary angiosarcomas are invariably (>90%) metastatic tumors form primaries of the skin, bone, liver, breast, or heart. Primary pulmonary angiosarcomas are exceedingly rare, with just about 20 cases being reported in the literature. We report an additional case with a brief review of the literature of a primary pulmonary angiosarcoma in a 26-year-old lady who presented with intractable hemoptysis. In addition, we highlight the potential of fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography as an important diagnostic tool in the evaluation of this tumor and thus contribute to the existing sparse literature on this fascinating yet devastating disease

  10. F-18-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Appearance of Extramedullary Hematopoesis in a Case of Primary Myelofibrosis

    Science.gov (United States)

    Mukherjee, Anirban; Bal, Chandrasekhar; Tripathi, Madhavi; Das, Chandan Jyoti; Shamim, Shamim Ahmed

    2017-01-01

    A 44-year-old female with known primary myelofibrosis presented with shortness of breath. High Resolution Computed Tomography thorax revealed large heterogeneously enhancing extraparenchymal soft tissue density mass involving bilateral lung fields. F-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography revealed mildly FDG avid soft tissue density mass with specks of calcification involving bilateral lung fields, liver, and spleen. Subsequent histopathologic evaluation from the right lung mass was suggestive of extramedullary hematopoesis. PMID:28533647

  11. Development of a simple photon emission computed tomography dedicated to the small animal

    International Nuclear Information System (INIS)

    Bekaert, V.

    2006-11-01

    The development of in vivo small animal imaging becomes essential to study human pathologies. The ImaBio project of Institut Pluridisciplinaire Hubert Curien (IPHC) fits in the process of developing new instruments for biomedical applications with the development of a multimodality imaging platform dedicated to small animal imaging (AMISSA). This thesis presents the study, the design and the development of a Single Photon Emission Computed Tomography (SPECT) which will be integrated to the AMISSA platform. The result of these developments is the possibility to obtain the spatial distribution of an injected molecule into the animal. The SPECT technical solutions are based on the acquired knowledge of the institute allowing the conception of a device with cameras adapted to the gamma detection produced by the radiotracers used in single photon imaging. In order to cover the entire of the transverse field of view, four gamma cameras are arranged in a ring around the volume of interest. Each camera consists of 5 individual modules based on a YAP:Ce crystal array, a multi-anode photomultiplier and a dedicated multichannel electronic device. Finally, 20 detection modules were calibrated to give the same result for an identical energy deposit. The data are acquired then process to extract the positions and the energies deposited by gamma photons in the crystals. This last information is then gathered to build the projections. The 3D reconstructed image from the projections is carried out by the sequence of two algorithms, analytical and iterative OS-EM, both modified to take into account the singular geometry of our detection system. Finally, the obtained image is fused with the anatomical information given by the micro Computed Tomography system. (author)

  12. Differentiation of malignant glioma and metastatic brain tumor by thallium-201 single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Yasuhiro; Kuwana, Nobumasa; Noji, Masato; Tosa, Junichi [Yokohama Minami Kyosai Hospital (Japan)

    1994-09-01

    The use of superdelayed thallium-201 single photon emission computed tomography ([sup 201]Tl SPECT) for differentiating malignant gliomas from cerebral metastases was investigated in 23 patients (7 with meningioma, 6 with glioma, 7 with cerebral metastasis, 1 with each of neurinoma, abscess, and necrosis). 4 mCi of [sup 201]Tl was injected intravenously, and gamma camera scans were performed after 10 minutes and 4, 24, 72, and 96 hours (superdelayed scan). The mean thallium index of meningiomas was significantly higher than those of gliomas and cerebral metastases after 10 minutes, while the mean thallium indices of meningiomas and gliomas were significantly higher than those of cerebral metastases after 96 hours. The combination of early and superdelayed [sup 201]Tl SPECT may be useful in differentiating malignant gliomas from cerebral metastases. (author).

  13. Emission and transmission tomography systems to be developed for the future needs of Jules Horowitz material testing reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kotiluoto, Petri [VTT Technical Research Centre of Finland, P.O.Box 1000, FI-02044 VTT (Finland)], E-mail: petri.kotiluoto@vtt.fi; Wasastjerna, Frej; Kekki, Tommi [VTT Technical Research Centre of Finland, P.O.Box 1000, FI-02044 VTT (Finland); Sipilae, Heikki; Banzuzi, Kukka [Oxford Instruments Analytical Oy, Nihtisillankuja 5, P.O.Box 85, FI-02631 Espoo (Finland); Kinnunen, Petri; Heikinheimo, Liisa [VTT Technical Research Centre of Finland, P.O.Box 1000, FI-02044 VTT (Finland)

    2009-08-01

    The new 100 MW Jules Horowitz material testing reactor will be built in Cadarache, France. It will support, for instance, research on new types of innovative nuclear fuel. As a Finnish in-kind contribution, 3D emission and transmission tomography equipment will be delivered for both the reactor and the active component storage pool. The image reconstruction of activities inside the used nuclear fuel will be based on gamma spectrometry measurements. A new type of underwater digital X-ray linear detector array is under development for transmission imaging, based on GaAs and direct conversion of X-rays into an electrical signal. A shared collimator will be used for both emission and transmission measurements. Some preliminary design has been performed. For the current design, the expected gamma spectrometric response of a typical high-purity germanium detector has been simulated with MCNP for minimum and maximum source activities (specified by CEA) to be measured in future.

  14. Report of two cases of fluorodeoxyglucose positron emission tomography/computed tomography appearance of hibernoma: A rare benign tumor

    International Nuclear Information System (INIS)

    Agrawal, Archi; Kembhavi, Seema; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2014-01-01

    False-positive findings are commonly seen in positron emission tomography computed tomography imaging. One of the most common false positive finding is uptake of fluorodeoxyglucose in brown adipose tissue. Herein, we report two cases with incidentally detected hibernomas-a brown fat containing tumor with metabolic activity

  15. Unusual sites of metastatic recurrence of osteosarcoma detected on fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography

    International Nuclear Information System (INIS)

    Kabnurkar, Rasika; Agrawal, Archi; Rekhi, Bharat; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2015-01-01

    Osteosarcoma (OS) is the most common nonhematolymphoid primary bone malignancy characterized by osteoid or new bone formation. Lungs and bones are the most common sites of metastases. We report a case where unusual sites of the soft tissue recurrence from OS were detected on restaging fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography scan done post 6 years of disease free interval

  16. The value of positron emission tomography/computed tomography for evaluating metastatic disease in patients with pancreatic cancer.

    Science.gov (United States)

    Kim, Mi-Jin; Lee, Kwang Hyuck; Lee, Kyu Taek; Lee, Jong Kyun; Ku, Bon-Ho; Oh, Cho-Rong; Heo, Jin Seok; Choi, Seong-Ho; Choi, Dong Wook

    2012-08-01

    Routine application of positron emission tomography/computed tomography (PET/CT) for pancreatic cancer staging remains a controversial approach. The purpose of this study was to reassess the clinical impact of PET/CT for the detection of distant metastasis of pancreatic cancer. From January 2006 to June 2009, 125 patients with histologically proven pancreatic cancer that had undergone PET/CT at our hospital were retrospectively reviewed. To evaluate the clinical efficacy of PET/CT on the management plan, the post-PET/CT management plans were compared with the pre-PET/CT management plans. After the conventional staging workup, we determined that 76 patients (60.8%) had resectable lesions, whereas 48 patients had unresectable lesions. One patient underwent explorative laparotomy due to equivocal resectability. Positron emission tomography/computed tomography diagnosed distant metastasis in only 2 (2.6%) of the 76 patients with resectable lesions, and these patients did not undergo unnecessary surgical treatment. Complete resection was not performed in 8 of the 74 operative patients because they had distant metastasis detected during the operative procedure. Positron emission tomography/computed tomography diagnosed distant metastasis in 32 of the 44 patients with metastatic lesions that were histologically shown to have sensitivity of 72.7%. Positron emission tomography/computed tomography has a limited role in the evaluation of metastatic disease from pancreatic cancer.

  17. Incidental head and neck findings on 18F-fluoro-deoxy-glucose positron emission tomography computed tomography.

    Science.gov (United States)

    Williams, S P; Kinshuck, A J; Williams, C; Dwivedi, R; Wieshmann, H; Jones, T M

    2015-09-01

    The overlapping risk factors for lung and head and neck cancer present a definite risk of synchronous malignant pathology. This is the first study to specifically review incidental positron emission tomography computed tomography findings in the head and neck region in lung carcinoma patients. A retrospective review was performed of all lung cancer patients who underwent positron emission tomography computed tomography imaging over a five-year period (January 2008 - December 2012), identified from the Liverpool thoracic multidisciplinary team database. Six hundred and nine patients underwent positron emission tomography computed tomography imaging over this period. In 76 (12.5 per cent) scans, incidental regions of avid 18F-fluoro-deoxy-glucose uptake were reported in the head and neck region. In the 28 patients who were fully investigated, there were 4 incidental findings of malignancy. In lung cancer patients undergoing investigative positron emission tomography computed tomography scanning, a significant number will also present with areas of clinically significant 18F-fluoro-deoxy-glucose uptake in the head and neck region. Of these, at least 5 per cent may have an undiagnosed malignancy.

  18. Extensive tumor thrombus of hepatocellular carcinoma in the entire portal venous system detected on fluorodeoxyglucose positron emission tomography computed tomography

    International Nuclear Information System (INIS)

    Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Puranik, Ameya; Rangarajan, Venkatesh

    2013-01-01

    Detection of thrombus is usually an incidental finding on fluorodeoxyglucose positron emission tomography/computed tomography studies. Nevertheless this is an important finding in terms of disease prognostication and in planning the treatment strategy. We herein report a case of a 50-years-old male, a diagnosed case of hepatocellular carcinoma with extensive hypermetabolic thrombus involving the entire portal venous system. (author)

  19. Diagnosis of sinusoidal obstruction syndrome by positron emission tomography/computed tomography: report of two cases treated by defibrotide.

    Science.gov (United States)

    Gauthé, Mathieu; Bozec, Laurence; Bedossa, Pierre

    2014-11-01

    Sinusoidal obstruction syndrome (SOS) is a potentially fatal liver injury that mainly occurs after myeloablative chemotherapy. We report two cases of SOS investigated by 18F-fluorodeoxyglucose positron emission tomography/computed tomography and treated with defibrotide. © 2014 by the American Association for the Study of Liver Diseases.

  20. Clinical applications of positron emission tomography in breast cancer patients

    International Nuclear Information System (INIS)

    Roemer, W.; Avril, N.; Schwaiger, M.

    1997-01-01

    Increased glucose metabolism by malignant tissue can be visualized with positron emission tomography (PET), using the radiolabeled glucose analogue F-18 fluorodeoxyglucose (FDG). Depending on the criteria of image interpretation FDG-PET allows detection of breast cancer with a sensitivity of 68% to 94 % and a specificity of 84 % to 97 %. However, sensitivity to visualize small tumors (< 1 cm) is limited. Positron emission tomography demonstrates tumor involvement of regional lymph nodes with high accuracy, predominantly in patients with advanced breast cancer. The sensitivity for the detection of axillary lymph node metastases was 79% with a corresponding specificity of 96 %. Lymph node metastases could not be identified in four of six patients with small primary breast cancer (stage pT1), resulting in a sensitivity of only 33% in these patients. By visualizing primary tumors and metastases in one imaging procedure, PET imaging may allow the effective staging of breast cancer patients. Further studies are needed to define the role of scintigraphic techniques for the diagnostic work-up in patients. (author)

  1. Positron emission tomography: Physics, instrumentation, and image analysis

    International Nuclear Information System (INIS)

    Porenta, G.

    1994-01-01

    Positron emission tomography (PET) is a noninvasive diagnostic technique that permits reconstruction of cross-sectional images of the human body which depict the biodistribution of PET tracer substances. A large variety of physiological PET tracers, mostly based on isotopes of carbon, nitrogen, oxygen, and fluorine is available and allows the in vivo investigation of organ perfusion, metabolic pathways and biomolecular processes in normal and diseased states. PET cameras utilize the physical characteristics of positron decay to derive quantitative measurements of tracer concentrations, a capability that has so far been elusive for conventional SPECT (single photon emission computed tomography) imaging techniques. Due to the short half lives of most PET isotopes, an on-site cyclotron and a radiochemistry unit are necessary to provide an adequate supply of PET tracers. While operating a PET center in the past was a complex procedure restricted to few academic centers with ample resources. PET technology has rapidly advanced in recent years and has entered the commercial nuclear medicine market. To date, the availability of compact cyclotrons with remote computer control, automated synthesis units for PET radiochemistry, high-performance PET cameras, and userfriendly analysis workstations permits installation of a clinical PET center within most nuclear medicine facilities. This review provides simple descriptions of important aspects concerning physics, instrumentation, and image analysis in PET imaging which should be understood by medical personnel involved in the clinical operation of a PET imaging center. (author)

  2. Nuclear medicine and positron emission tomography: An overview

    International Nuclear Information System (INIS)

    McCarthy, T.J.; Schwarz, S.W.; Welch, M.J.

    1994-01-01

    Nuclear medicine is the field of medical practice that involves the oral or intravenous administration of radioactive materials for use in diagnosis and therapy. The majority of radiopharmaceutical available are used for diagnostic purposes. These involve the determination of organ function, shape, or position from an image of the radioactivity distribution within an organ or at a location within the body. After administration, the radiopharmaceutical localizes within an organ or target tissue due to its biological or physiologic characteristics. This diagnostic capability is usually the result of the emission of gamma radiation from the radiopharmaceutical localized within an organ. This allows for external detection and imaging using a special type of camera known as a gamma camera. When a positron-emitting radionuclide decays, a positron (positive electron) is emitted from the nucleus. The positron then annihilates with an electron, resulting in the release of energy in the form of two 511-KeV γ-rays at 180 degree to one another. The energy of these photons is sufficient to pass through tissue. Thus, placing a series of detectors around the patient allows technicians to monitor the emission of both of the photons that result from a single positron annihilation. this ultimately allows an accurate quantification of the distribution of radioactivity in the body not possible when only a single γ-ray is emitted

  3. Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography and (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for recurrent prostate carcinoma: results of a prospective clinical trial.

    Science.gov (United States)

    Schuster, David M; Nieh, Peter T; Jani, Ashesh B; Amzat, Rianot; Bowman, F Dubois; Halkar, Raghuveer K; Master, Viraj A; Nye, Jonathon A; Odewole, Oluwaseun A; Osunkoya, Adeboye O; Savir-Baruch, Bital; Alaei-Taleghani, Pooneh; Goodman, Mark M

    2014-05-01

    We prospectively evaluated the amino acid analogue positron emission tomography radiotracer anti-3-[(18)F]FACBC compared to ProstaScint® ((111)In-capromab pendetide) single photon emission computerized tomography-computerized tomography to detect recurrent prostate carcinoma. A total of 93 patients met study inclusion criteria who underwent anti-3-[(18)F]FACBC positron emission tomography-computerized tomography plus (111)In-capromab pendetide single photon emission computerized tomography-computerized tomography for suspected recurrent prostate carcinoma within 90 days. Reference standards were applied by a multidisciplinary board. We calculated diagnostic performance for detecting disease. In the 91 of 93 patients with sufficient data for a consensus on the presence or absence of prostate/bed disease anti-3-[(18)F]FACBC had 90.2% sensitivity, 40.0% specificity, 73.6% accuracy, 75.3% positive predictive value and 66.7% negative predictive value compared to (111)In-capromab pendetide with 67.2%, 56.7%, 63.7%, 75.9% and 45.9%, respectively. In the 70 of 93 patients with a consensus on the presence or absence of extraprostatic disease anti-3-[(18)F]FACBC had 55.0% sensitivity, 96.7% specificity, 72.9% accuracy, 95.7% positive predictive value and 61.7% negative predictive value compared to (111)In-capromab pendetide with 10.0%, 86.7%, 42.9%, 50.0% and 41.9%, respectively. Of 77 index lesions used to prove positivity histological proof was obtained in 74 (96.1%). Anti-3-[(18)F]FACBC identified 14 more positive prostate bed recurrences (55 vs 41) and 18 more patients with extraprostatic involvement (22 vs 4). Anti-3-[(18)F]FACBC positron emission tomography-computerized tomography correctly up-staged 18 of 70 cases (25.7%) in which there was a consensus on the presence or absence of extraprostatic involvement. Better diagnostic performance was noted for anti-3-[(18)F]FACBC positron emission tomography-computerized tomography than for (111)In-capromab pendetide single

  4. Dynamic positron emission tomography for study of cerebral hemodynamics in a cross section of the head using positron-emitting 68Ga-EDTA and 77Kr

    International Nuclear Information System (INIS)

    Yamamoto, Y.L.; Thompson, C.J.; Meyer, E.; Robertson, J.S.; Feindel, W.

    1977-01-01

    Dynamic positron emission tomographic studies were performed on over 120 patients with occlusive cerebrovascular disease, arteriovenous malformations, and brain tumors, using the positron section scanner, consisting of a ring of 32 scintillation detectors. The radiopharmaceuticals were nondiffusible 68 Ga-EDTA for transit time and uptake studies and the diffusible tracer, 77 Kr, for quantitative regional cerebral blood flow studies in every square centimeter of the cross section of the head. The results of dynamic positron emission tomography in correlation with the results from the gamma scintillation camera dynamic studies and computed tomography (CT) scans are discussed

  5. Budget impact from the incorporation of positron emission tomography ? computed tomography for staging lung cancers

    OpenAIRE

    Biz, Aline Navega; Caetano, Ros?ngela

    2015-01-01

    OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer.METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazi...

  6. A single photon emission computed tomograph based on a limited dumber of detectors for fluid flow visualization; Tomographie d'emission gamma a partir d'un nombre limite de detecteurs appliquee a la visualisation d'ecoulements

    Energy Technology Data Exchange (ETDEWEB)

    Legoupil, S

    1999-07-01

    We present in this work a method for fluid flow visualization in a system using radioactive tracers. The method is based on single photon emission computed tomography techniques, applied to a limited number of discrete detectors. We propose in this work a method for the estimation of the transport matrix of photons, associated to the acquisition system.This method is based on the modelization of profiles acquired for a set of point sources located in the imaged volume. Monte Carlo simulations allow to separate scattered photons from those directly collected by the system. The influence of the energy tracer is exposed. The reconstruction method is based on the maximum likelihood - expectation maximization algorithm. An experimental device, based on 36 detectors was realised for the visualization of water circulation in a vessel. A video monitoring allows to visualize the dye water tracer. Dye and radioactive tracers are injected simultaneously in a water flow circulating in the vessel. Reconstructed and video images are compared. Quantitative and qualitative analysis show that fluid flow visualization is feasible with a limited number of detectors. This method can be applied for system involving circulations of fluids. (author)

  7. ¹⁸F-fluorodeoxyglucose positron emission tomography-computed tomography for the evaluation of bone metastasis in patients with gastric cancer.

    Science.gov (United States)

    Ma, Dae Won; Kim, Jie-Hyun; Jeon, Tae Joo; Lee, Yong Chan; Yun, Mijin; Youn, Young Hoon; Park, Hyojin; Lee, Sang In

    2013-09-01

    The roles of positron emission tomography and bone scanning in identifying bone metastasis in gastric cancer are unclear. We compared the usefulness of positron emission tomography-computed tomography and scanning in detecting bone metastasis in gastric cancer. Data from 1485 patients diagnosed with gastric cancer who had undergone positron emission tomography-computed tomography and scanning were reviewed. Of 170 enrolled patients who were suspected of bone metastasis in either positron emission tomography or scanning, 81.2% were confirmed to have bone metastasis. The sensitivity, specificity, and accuracy were 93.5%, 25.0%, and 80.6%, respectively, for positron emission tomography and 93.5%, 37.5%, and 82.9%, respectively, for scanning. 87.7% of patients with bone metastasis showed positive findings on two modalities. 15.0% of solitary bone metastases were positive on positron emission tomography only. Positron emission tomography was superior to scanning for the detection of synchronous bone metastasis, but the two modalities were similar for the detection of metachronous bone metastasis. The concordance rate of response assessment after treatment between two modalities was moderate. Positron emission tomography-computed tomography may be more effective for the diagnosis of bone metastasis in the initial staging workup. Conversely, bone scanning and positron emission tomography-computed tomography may be similarly effective for the detection of metachronous bone metastasis. Copyright © 2013 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  8. A method for measuring the energy spectrum of coincidence events in positron emission tomography.

    Science.gov (United States)

    Goertzen, Andrew L; Stout, David B; Thompson, Christopher J

    2010-01-21

    Positron emission tomography (PET) system energy response is typically characterized in singles detection mode, yet there are situations in which the energy spectrum of coincidence events might be different than the spectrum measured in singles mode. Examples include imaging with isotopes that emit a prompt gamma in coincidence with a positron emission, imaging with low activity in a LSO/LYSO-based cameras, in which the intrinsic activity is significant, and in high scatter situations where the two 511 keV photons have different scattering probabilities (i.e. off-center line source). The ability to accurately measure the energy spectrum of coincidence events could be used for validating simulation models, optimizing energy discriminator levels and examining scatter models and corrections. For many PET systems operating in coincidence mode, the only method available for estimating the energy spectrum is to step the lower and upper level discriminators (LLD and ULD). Simple measurement techniques such as using a narrow sliding energy window or stepping only the LLD will not yield a spectrum of coincidence events that is accurate for cases where there are different energy components contributing to the spectrum. In this work we propose a new method of measuring the energy spectrum of coincidence events in PET based on a linear combination of two sets of coincident count measurements: one made by stepping the LLD and one made by stepping the ULD. The method was tested using both Monte Carlo simulations of a Siemens microPET R4 camera and measured data acquired on a Siemens Inveon PET camera. The results show that our energy spectrum calculation method accurately measures the coincident energy spectra for cases including the beta/gamma spectrum of the (176)Lu intrinsic activity present in the LSO scintillator crystals, a (68)Ge source and an (124)I source (in which there are prompt gamma-rays emitted together with the positron).

  9. Is there any role of positron emission tomography computed tomography for predicting resectability of gallbladder cancer?

    Science.gov (United States)

    Kim, Jaihwan; Ryu, Ji Kon; Kim, Chulhan; Paeng, Jin Chul; Kim, Yong-Tae

    2014-05-01

    The role of integrated (18)F-2-fluoro-2-deoxy-D-glucose positron emission tomography computed tomography (PET-CT) is uncertain in gallbladder cancer. The aim of this study was to show the role of PET-CT in gallbladder cancer patients. Fifty-three patients with gallbladder cancer underwent preoperative computed tomography (CT) and PET-CT scans. Their medical records were retrospectively reviewed. Twenty-six patients underwent resection. Based on the final outcomes, PET-CT was in good agreement (0.61 to 0.80) with resectability whereas CT was in acceptable agreement (0.41 to 0.60) with resectability. When the diagnostic accuracy of the predictions for resectability was calculated with the ROC curve, the accuracy of PET-CT was higher than that of CT in patients who underwent surgical resection (P=0.03), however, there was no difference with all patients (P=0.12). CT and PET-CT had a discrepancy in assessing curative resection in nine patients. These consisted of two false negative and four false positive CT results (11.3%) and three false negative PET-CT results (5.1%). PET-CT was in good agreement with the final outcomes compared to CT. As a complementary role of PEC-CT to CT, PET-CT tended to show better prediction about resectability than CT, especially due to unexpected distant metastasis.

  10. Nondestructive assay of TRU waste using gamma-ray active and passive computed tomography

    International Nuclear Information System (INIS)

    Roberson, G.P.; Decman, D.; Martz, H.; Keto, E.R.; Johansson, E.M.

    1995-01-01

    The authors have developed an active and passive computed tomography (A and PCT) scanner for assaying radioactive waste drums. Here they describe the hardware components of their system and the software used for data acquisition, gamma-ray spectroscopy analysis, and image reconstruction. They have measured the performance of the system using ''mock'' waste drums and calibrated radioactive sources. They also describe the results of measurements using this system to assay a real TRU waste drum with relatively low Pu content. The results are compared with X-ray NDE studies of the same TRU waste drum as well as assay results from segmented gamma scanner (SGS) measurements

  11. Positron emission tomography/computed tomography surveillance in patients with Hodgkin lymphoma in first remission has a low positive predictive value and high costs.

    Science.gov (United States)

    El-Galaly, Tarec Christoffer; Mylam, Karen Juul; Brown, Peter; Specht, Lena; Christiansen, Ilse; Munksgaard, Lars; Johnsen, Hans Erik; Loft, Annika; Bukh, Anne; Iyer, Victor; Nielsen, Anne Lerberg; Hutchings, Martin

    2012-06-01

    The value of performing post-therapy routine surveillance imaging in patients with Hodgkin lymphoma is controversial. This study evaluates the utility of positron emission tomography/computed tomography using 2-[18F]fluoro-2-deoxyglucose for this purpose and in situations with suspected lymphoma relapse. We conducted a multicenter retrospective study. Patients with newly diagnosed Hodgkin lymphoma achieving at least a partial remission on first-line therapy were eligible if they received positron emission tomography/computed tomography surveillance during follow-up. Two types of imaging surveillance were analyzed: "routine" when patients showed no signs of relapse at referral to positron emission tomography/computed tomography, and "clinically indicated" when recurrence was suspected. A total of 211 routine and 88 clinically indicated positron emission tomography/computed tomography studies were performed in 161 patients. In ten of 22 patients with recurrence of Hodgkin lymphoma, routine imaging surveillance was the primary tool for the diagnosis of the relapse. Extranodal disease, interim positron emission tomography-positive lesions and positron emission tomography activity at response evaluation were all associated with a positron emission tomography/computed tomography-diagnosed preclinical relapse. The true positive rates of routine and clinically indicated imaging were 5% and 13%, respectively (P = 0.02). The overall positive predictive value and negative predictive value of positron emission tomography/computed tomography were 28% and 100%, respectively. The estimated cost per routine imaging diagnosed relapse was US$ 50,778. Negative positron emission tomography/computed tomography reliably rules out a relapse. The high false positive rate is, however, an important limitation and a confirmatory biopsy is mandatory for the diagnosis of a relapse. With no proven survival benefit for patients with a pre-clinically diagnosed relapse, the high costs and low

  12. Plasma Emission Profile Recreation using Soft X-Ray Tomography

    Science.gov (United States)

    Page, J. W.; Mauel, M. E.; Levesque, J. P.

    2015-11-01

    With sufficient views from multiple diode arrays, soft X-ray tomography is an invaluable plasma diagnostic because it is a non-perturbing method to reconstruct the emission within the interior of the plasma. In preparation for the installation of new SXR arrays in HBT-EP, we compute high-resolution tomographic reconstructions of discharges having kink-like structures that rotate nearly rigidly. By assuming a uniform angular mapping from the kink mode rotation, Δϕ ~ ωΔ t, a temporal sequence from a single 16-diode fan array represents as many as 16 x 100 independent views. We follow the procedure described by Wang and Granetz and use Bessel basis functions to take the inverse Radon transform. This transform is fit to our data using a least-squares method to estimate the internal SXR emissivity as a sum of polar functions. By varying different parameters of the transformation, we optimize the quality of our recreation of the emission profile and quantify how the reconstruction changes with the azimuthal order of the transform. Supported by U.S. DOE Grant DE-FG02-86ER53222.

  13. 77 FR 71802 - Guidance on Investigational New Drug Applications for Positron Emission Tomography Drugs...

    Science.gov (United States)

    2012-12-04

    ... Positron Emission Tomography (PET) Drugs.'' The guidance is intended to assist manufacturers of PET drugs... one self-addressed adhesive label to assist that office in processing your requests. See the... ``Investigational New Drug Applications for Positron Emission Tomography (PET) Drugs.'' The guidance summarizes the...

  14. A library least-squares approach for scatter correction in gamma-ray tomography

    Science.gov (United States)

    Meric, Ilker; Anton Johansen, Geir; Valgueiro Malta Moreira, Icaro

    2015-03-01

    Scattered radiation is known to lead to distortion in reconstructed images in Computed Tomography (CT). The effects of scattered radiation are especially more pronounced in non-scanning, multiple source systems which are preferred for flow imaging where the instantaneous density distribution of the flow components is of interest. In this work, a new method based on a library least-squares (LLS) approach is proposed as a means of estimating the scatter contribution and correcting for this. The validity of the proposed method is tested using the 85-channel industrial gamma-ray tomograph previously developed at the University of Bergen (UoB). The results presented here confirm that the LLS approach can effectively estimate the amounts of transmission and scatter components in any given detector in the UoB gamma-ray tomography system.

  15. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E. (National Institute of Aging, Baltimore, MD (USA))

    1990-11-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas.

  16. Evaluation of brain tumours by positron emission tomography

    International Nuclear Information System (INIS)

    Schober, O.; Meyer, G.J.

    1992-01-01

    The clinical application of positron emission tomography (PET) for the evaluation of brain tumours has proved clinically valuable. Amino acid and FDG-glucose PET provide information on the degree of malignancy and the prognosis during the initial evaluation. After therapy, the residual tumour can be visualized and recurrence can be differentiated from necrosis. Amino acids have advantages over FDG for these clinical applications. Blood flow, oxygen extraction and metabolism and blood-brain barrier permeability are of minor relevance in clinical situations. Comparison of PET with MRI and MRS will provide new data. The quantitative information of the unique information yielded by PET will lead to a more important clinical role, as will the extrapolation of this experience to the SPECT technique. (orig.) [de

  17. Single photon emission computed tomography of the liver

    International Nuclear Information System (INIS)

    Makler, P.T. Jr.

    1988-01-01

    Single photon emission computed tomography (SPECT) of the liver has been introduced in order to improve sensitivity and localization of space-occupying lesions. There have been numerous reports on the usefulness of the technique, as well as extensive analyses of its technical drawbacks. In general, SPECT provides a more accurate estimation of defect size than does conventional planar scintigraphy for cases in which one wishes to evaluate changes in lesion size due to therapy. The presence of a superimposed parenchymal disease, however, remains a major problem, which will only be resolved by a scanning technique that specifically detects the disease process of concern (hot spot imaging) rather than displacement of normal tissue (cold spot imaging)

  18. Temporoparietal cortex in aphasia. Evidence from positron emission tomography

    International Nuclear Information System (INIS)

    Metter, E.J.; Hanson, W.R.; Jackson, C.A.; Kempler, D.; van Lancker, D.; Mazziotta, J.C.; Phelps, M.E.

    1990-01-01

    Forty-four aphasic patients were examined with (F18)-fluorodeoxyglucose positron emission tomography in a resting state to determine whether consistent glucose metabolic abnormalities were present. Ninety-seven percent of subjects showed metabolic abnormalities in the angular gyrus, 89% in the supramarginal gyrus, and 87% in the lateral and transverse superior temporal gyrus. Pearson product moment correlations were calculated between regional metabolic measures and performance on the Western Aphasia Battery. No significant correlations were found between the Western Aphasia Battery scores and right hemisphere metabolic measures. Most left hemisphere regions correlated with more than one score from the Western Aphasia Battery. Temporal but not frontal regions had significant correlations to the comprehension score. The left temporoparietal region was consistently affected in these subjects, suggesting that common features in the aphasias were caused by left temporoparietal dysfunction, while behavioral differences resulted from (1) the extent of temporoparietal changes, and (2) dysfunction elsewhere in the brain, particularly the left frontal and subcortical areas

  19. Studies of the brain cannabinoid system using positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Gatley, S.J.; Volkow, N.D.

    1995-10-01

    Studies using radiolabeled psychoactive drugs in conjunction with positron emission tomography (PET) have permitted the imaging of binding sites in the human brain. Similar studies of marijuana have been hampered by the unsuitability of radiolabeled THC for PET studies, and the current unavailability of other in vivo imaging agents for cannabinoid receptors. Recent developments in medicinal chemistry suggest that a PET radiotracer for cannabinoid receptors will soon become available. This chapter briefly reviews these developments, together with the results of PET studies of the effects of marijuana and other abused drugs on brain metabolism. It also reviews PET studies of cocaine binding sites, to demonstrate the kind of investigations that will be possible when a cannabinoid receptor PET radioligand becomes available.

  20. An automated blood sampling system used in positron emission tomography

    International Nuclear Information System (INIS)

    Eriksson, L.; Bohm, C.; Kesselberg, M.

    1988-01-01

    Fast dynamic function studies with positron emission tomography (PET), has the potential to give accurate information of physiological functions of the brain. This capability can be realised if the positron camera system accurately quantitates the tracer uptake in the brain with sufficiently high efficiency and in sufficiently short time intervals. However, in addition, the tracer concentration in blood, as a function of time, must be accurately determined. This paper describes and evaluates an automated blood sampling system. Two different detector units are compared. The use of the automated blood sampling system is demonstrated in studies of cerebral blood flow, in studies of the blood-brain barrier transfer of amino acids and of the cerebral oxygen consumption. 5 refs.; 7 figs

  1. Positron Emission Tomography: state of the art and future developments

    International Nuclear Information System (INIS)

    Pizzichemi, M.

    2016-01-01

    Positron emission tomography (PET) plays a fundamental role in medical imaging, with a wide range of applications covering, among the others, oncology, neurology and cardiology. PET has undergone a steady technological evolution since its introduction in mid 20th century, from the development of 3D PET in the late 1980s, to the invention of PET/CT in the 1990s and more recently with the introduction of PET/MR scanners. The current research topics aiming to develop the next generation of PET scanners are summarized in this paper, focusing on the efforts to increase the sensitivity of the detectors, as long as improving their timing, spatial and energy resolutions, with the final goal of reducing the amount of radioactive dose received by the patients and the duration of the exams while improving at the same time the detectability of lesions.

  2. Studies of the brain cannabinoid system using positron emission tomography

    International Nuclear Information System (INIS)

    Gatley, S.J.; Volkow, N.D.

    1995-01-01

    Studies using radiolabeled psychoactive drugs in conjunction with positron emission tomography (PET) have permitted the imaging of binding sites in the human brain. Similar studies of marijuana have been hampered by the unsuitability of radiolabeled THC for PET studies, and the current unavailability of other in vivo imaging agents for cannabinoid receptors. Recent developments in medicinal chemistry suggest that a PET radiotracer for cannabinoid receptors will soon become available. This chapter briefly reviews these developments, together with the results of PET studies of the effects of marijuana and other abused drugs on brain metabolism. It also reviews PET studies of cocaine binding sites, to demonstrate the kind of investigations that will be possible when a cannabinoid receptor PET radioligand becomes available

  3. Axial positrons emission tomography: from mouse to human brain imaging

    International Nuclear Information System (INIS)

    Brard, Emmanuel

    2013-01-01

    Positrons emission tomography is a nuclear imaging technics using nuclear decays. It is used both in clinical and preclinical studies. The later requires the use of small animals such as the mouse. The objective is to obtain the best signal with the best spatial resolution. Yet, a weight ratio between humans and mice indicates the need of a sub-millimeter resolution. A conventional scanner is based on detection modules surrounding the object to image and arranged perpendicularly. This implies a strong relationship between efficiency and spatial resolution. This work focuses on the axial geometry in which detection modules are arranged parallel to the object. This limits the relationship between the figures of merit, leading to both high spatial resolution and efficiency. The simulations of prototypes showed great perspectives in term of sub-millimeter resolution with efficiencies of 15 or 40% according to the scanner's axial extension. These results indicate great perspectives for both clinical and preclinical imaging. (author)

  4. A Case of Corticobasal Degeneration Studied with Positron Emission Tomography

    Directory of Open Access Journals (Sweden)

    H. Nagasawa

    1993-01-01

    Full Text Available We measured cerebral blood flow, oxygen metabolism, glucose utilization, and dopamine metabolism in the brain of a patient with corticobasal degeneration using positron emission tomography (PET. The clinical picture is distinctive, comprising features referable to both cortical and basal ganglionic dysfunction. Brain imagings of glucose and dopamine metabolism can demonstrate greater abnormalities in the cerebral cortex and in the striatum contralateral to the more affected side than those of blood flow and oxygen metabolism. This unique combination study measuring both cerebral glucose utilization and dopamine metabolism in the nigrostriatal system can provide efficient information about the dysfunctions which are correlated with individual clinical symptoms, and this study is essential to diagnosis of corticobasal degeneration.

  5. Differential diagnosis of depression: relevance of positron emission tomography

    International Nuclear Information System (INIS)

    Schwartz, J.M.; Baxter, L.R. Jr.; Mazziotta, J.C.; Gerner, R.H.; Phelps, M.E.

    1987-01-01

    The proper differential diagnosis of depression is important. A large body of research supports the division of depressive illness into bipolar and unipolar subtypes with respect to demographics, genetics, treatment response, and neurochemical mechanisms. Optimal treatment is different for unipolar and bipolar depressions. Treating a patient with bipolar depression as one would a unipolar patient may precipitate a serious manic episode or possibly even permanent rapid cycling disorder. The clinical distinction between these disorders, while sometimes difficult, can often be achieved through an increased diagnostic suspicion concerning a personal or family history of mania. Positron emission tomography and the FDG method, which allow in vivo study of the glucose metabolic rates for discrete cerebral structures, provide new evidence that bipolar and unipolar depression are two different disorders

  6. Evaluating patients with ischemic cerebrovascular disease using positron emission tomography

    International Nuclear Information System (INIS)

    Raichle, M.E.

    1982-01-01

    Recent advances in nuclear medicine imaging techniques offer an important alternative for the evaluation of therapy for ischemic cerebrovascular disease. In particular, positron emission tomography (PET), with its capacity to provide quantitative measurements of brain blood flow, metabolism and biochemistry on a truly regional basis, now offers the opportunity to evaluate therapy in terms of specific changes in these parameters. By doing this PET permits one to study the problem on an individual patient basis with each subject serving as his own control. The author has been pursuing this approach in patients considered candidates for superficial temporal artery-middle cerebral artery anastomosis to bypass major stenotic or occlusive lesions of the internal carotid or middle cerebral artery. The results indicate that PET is of considerable value in establishing much more exactly the pathophysiology of certain forms of ischemic cerebrovascular disease and evaluating a form of therapy designed to correct the basic underlying defect. (Auth./C.F.)

  7. Knowledge-based automated radiopharmaceutical manufacturing for Positron Emission Tomography

    International Nuclear Information System (INIS)

    Alexoff, D.L.

    1991-01-01

    This article describes the application of basic knowledge engineering principles to the design of automated synthesis equipment for radiopharmaceuticals used in Positron Emission Tomography (PET). Before discussing knowledge programming, an overview of the development of automated radiopharmaceutical synthesis systems for PET will be presented. Since knowledge systems will rely on information obtained from machine transducers, a discussion of the uses of sensory feedback in today's automated systems follows. Next, the operation of these automated systems is contrasted to radiotracer production carried out by chemists, and the rationale for and basic concepts of knowledge-based programming are explained. Finally, a prototype knowledge-based system supporting automated radiopharmaceutical manufacturing of 18FDG at Brookhaven National Laboratory (BNL) is described using 1stClass, a commercially available PC-based expert system shell

  8. Determination of the attenuation map in emission tomography

    CERN Document Server

    Zaidi, H

    2002-01-01

    Reliable attenuation correction methods for quantitative emission computed tomography (ECT) require accurate delineation of the body contour and often necessitate knowledge of internal anatomical structure. Two broad classes of methods have been used to calculate the attenuation map referred to as "transmissionless" and transmission-based attenuation correction techniques. While calculated attenuation correction belonging to the first class of methods is appropriate for brain studies, more adequate methods must be performed in clinical applications where the attenuation coefficient distribution is not known a priori, and for areas of inhomogeneous attenuation such as the chest. Measured attenuation correction overcomes this problem and utilizes different approaches to determine this map including transmission scanning, segmented magnetic resonance images or appropriately scaled X-ray CT scans acquired either independently on separate or simultaneously on multimodality imaging systems. Combination of data acqu...

  9. Radiopharmaceuticals for positron emission tomography investigations of Alzheimer's disease

    International Nuclear Information System (INIS)

    Naagren, Kjell; Halldin, Christer; Rinne, Juha O.

    2010-01-01

    Alzheimer's disease (AD) is a common degenerative neurological disease that is an increasing medical, economical, and social problem. There is evidence that a long ''asymptomatic'' phase of the disease exists where functional changes in the brain are present, but structural imaging for instance with magnetic resonance imaging remains normal. Positron emission tomography (PET) is one of the tools by which it is possible to explore changes in cerebral blood flow and metabolism and the functioning of different neurotransmitter systems. More recently, investigation of protein aggregations such as amyloid deposits or neurofibrillary tangles containing tau-protein has become possible. The purpose of this paper is to review the current knowledge on various 18 F- and 11 C-labelled PET tracers that could be used to study the pathophysiology of AD, to be used in the early or differential diagnosis or to be used in development of treatment and in monitoring of treatment effects. (orig.)

  10. Brain abnormalities in murderers indicated by positron emission tomography.

    Science.gov (United States)

    Raine, A; Buchsbaum, M; LaCasse, L

    1997-09-15

    Murderers pleading not guilty by reason of insanity (NGRI) are thought to have brain dysfunction, but there have been no previous studies reporting direct measures of both cortical and subcortical brain functioning in this specific group. Positron emission tomography brain imaging using a continuous performance challenge task was conducted on 41 murderers pleading not guilty by reason of insanity and 41 age- and sex-matched controls. Murderers were characterized by reduced glucose metabolism in the prefrontal cortex, superior parietal gyrus, left angular gyrus, and the corpus callosum, while abnormal asymmetries of activity (left hemisphere lower than right) were also found in the amygdala, thalamus, and medial temporal lobe. These preliminary findings provide initial indications of a network of abnormal cortical and subcortical brain processes that may predispose to violence in murderers pleading NGRI.

  11. Investigation of language lateralization mechanism by Positron Emission Tomography

    International Nuclear Information System (INIS)

    Belin, Pascal

    1997-01-01

    As language lateralization in the brain left hemisphere is one of the most well known but less understood characteristics of the human brain, this research thesis reports the use of brain functional imaging to address some specific aspects of this lateralization. In a first part, the author reports the study of mechanisms of recovery from aphasia after a left hemisphere lesion within a population of aphasic right-handers. Based on a contrast between patients with a persistent aphasia despite usual language therapies, and patients with a significant recovery after a melodic and rhythmic therapy (TMR), a PET-based (positron emission tomography) activation study has been developed, based on the opposition between usual language stimuli and stimuli accentuated by TMR. In the second part, the author explored more systematically on sane patients the influence of some physical characteristics of auditory stimulation on the induced functional asymmetry [fr

  12. Clinical cardiac positron emission tomography: State of the art

    International Nuclear Information System (INIS)

    Gould, K.L.

    1991-01-01

    Cardiac positron emission tomography (PET) has evolved rapidly from a relatively esoteric research tool into clinical applications providing unique, quantitative information on myocardial perfusion, metabolism, and cell membrane function and having a potentially significant impact on cardiovascular medicine. Although there are many different positron radionuclides for imaging diverse myocardial behavior, three radionuclides have reached accepted clinical utility. Cardiac PET using nitrogen-13-ammonia, rubidium-82, and fluoro-18-deoxyglucose has proved accurate and definitive in multiple university and private-practice sites for diagnosing and assessing severity and location of coronary artery disease in symptomatic or asymptomatic patients, for identifying injured but viable myocardium potentially salvageable by revascularization, and for ruling out clinically significant coronary artery stenosis with a high specificity in patients who might otherwise undergo coronary arteriography to document the absence of significant disease. 89 references

  13. F-18-fluorodeoxyglucose-positron-emission tomography in neurology

    International Nuclear Information System (INIS)

    Fazekas, F.; Payer, F.

    2002-01-01

    Positron emission tomography using F-18-fluorodeoxyglucose (F-18-FDG-PET) is an ideal tool for imaging regional cerebral metabolism as glucose is the most important source of energy for neurons. Under physiologic conditions the pattern of metabolism reflects the state of cerebral activation which can be modulated by various stimuli to investigate cerebral organization. Pathologic conditions usually cause a drop in metabolism because of neuronal inactivity or loss. They can, however, also be associated with an increased rate of glucose metabolism such as in case of active epileptic foci or malignant tumors. As a consequence F-18-FDG-PET has become a valuable functional imaging modality especially for the diagnostic clarification of non-contributory or negative morphologic imaging results. Dementia, pre-surgical evaluation of epilepsy and neurooncology are currently frequent indications for referral to F-18-FDG-PET in neurology. (author)

  14. Fluorodeoxyglucose positron emission tomography in pancreatic cancer: an unsolved problem

    International Nuclear Information System (INIS)

    Kato, Takashi; Fukatsu, Hiroshi; Ito, Kengo; Tadokoro, Masanori; Ota, Toyohiro; Ikeda, Mitsuru; Isomura, Takayuki; Ito, Shigeki; Nishino, Masanari; Ishigaki, Takeo

    1995-01-01

    The aim of this study was to examine the significance and problems of 2-[fluorine-18]-2-deoxy-d-glucose (FDG) positron emission tomography (PET) in diagnosing pancreatic cancer and mass-forming pancreatitis (MFP). PET, X-ray computed tomography (CT) and magnetic resonance (MR) imaging were performed in 15 patients with pancreatic cancer and nine patients with MFP. The areas of the PET scan were determined according to the markers drawn on the patients at CT or MR imaging. Regions of interests (ROIs) were placed by reference to the CT or MR images corresponding to the PET images. Tissue metabolism was evaluated by the differential absorption ratio (DAR) at 50 min after intravenous injection of FDG [DAR = tissue tracer concentration/(injected dose/body weight). The DAR value differed significantly in pancreatic cancer (mean±SD, 4.64±1.94) and MFP (mean±SD, 2.84±2.22) (P<0.05). In one false-negative case (mucinous adenocarcinoma), the tumour contained a small number of malignant cells. In one false-positive case, lymphocytes accumulated densely in the mass in the pancreatic head. Further studies are necessary to investigate the histopathological characteristics (especially the cellularity) and other factors affecting the FDG DAR on PET images. (orig.)

  15. Denoising multicriterion iterative reconstruction in emission spectral tomography

    Science.gov (United States)

    Wan, Xiong; Yin, Aihan

    2007-03-01

    In the study of optical testing, the computed tomogaphy technique has been widely adopted to reconstruct three-dimensional distributions of physical parameters of various kinds of fluid fields, such as flame, plasma, etc. In most cases, projection data are often stained by noise due to environmental disturbance, instrumental inaccuracy, and other random interruptions. To improve the reconstruction performance in noisy cases, an algorithm that combines a self-adaptive prefiltering denoising approach (SPDA) with a multicriterion iterative reconstruction (MCIR) is proposed and studied. First, the level of noise is approximately estimated with a frequency domain statistical method. Then the cutoff frequency of a Butterworth low-pass filter was established based on the evaluated noise energy. After the SPDA processing, the MCIR algorithm was adopted for limited-view optical computed tomography reconstruction. Simulated reconstruction of two test phantoms and a flame emission spectral tomography experiment were employed to evaluate the performance of SPDA-MCIR in noisy cases. Comparison with some traditional methods and experiment results showed that the SPDA-MCIR combination had obvious improvement in the case of noisy data reconstructions.

  16. Positron Emission Tomography with Three-Dimensional Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of `mobile pixels`, which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs.

  17. Positron Emission Tomography with Three-Dimensional Reconstruction

    International Nuclear Information System (INIS)

    Erlandsson, K.

    1996-10-01

    The development of two different low-cost scanners for positron emission tomography (PET) based on 3D acquisition are presented. The first scanner consists of two rotating scintillation cameras, and produces quantitative images, which have shown to be clinically useful. The second one is a system with two opposed sets of detectors, based on the limited angle tomography principle, dedicated for mammographic studies. The development of low-cost PET scanners can increase the clinical impact of PET, which is an expensive modality, only available at a few centres world-wide and mainly used as a research tool. A 3D reconstruction method was developed that utilizes all the available data. The size of the data-sets is considerably reduced, using the single-slice rebinning approximation. The 3D reconstruction is divided into 1D axial deconvolution and 2D transaxial reconstruction, which makes it relatively fast. This method was developed for the rotating scanner, but was also implemented for multi-ring scanners with and without inter plane septa. An iterative 3D reconstruction method was developed for the limited angle scanner, based on the new concept of 'mobile pixels', which reduces the finite pixel errors and leads to an improved signal to noise ratio. 100 refs

  18. Hepatic Pseudolymphoma with Fluorodeoxyglucose Uptake on Positron Emission Tomography

    Directory of Open Access Journals (Sweden)

    Kazuhiro Suzumura

    2017-12-01

    Full Text Available A 69-year-old woman with chronic hepatitis B was admitted to our hospital with a hepatic tumor. The levels of 2 tumor markers, carcinoembryonic antigen and carbohydrate antigen 19-9, were slightly elevated; however, the α-fetoprotein and protein levels induced by vitamin K antagonist II were within the normal limits. Abdominal ultrasonography showed a well-defined peripheral hypoechoic mass that was isoechoic and homogeneous on the inside. Computed tomography showed a poorly enhanced tumor of 13 mm in diameter in the 5th segment of the liver. Fluorodeoxyglucose positron emission tomography showed a slight uptake (maximum standard uptake value 3.4 by the hepatic tumor. These findings suggested cholangiocellular carcinoma, and we performed anterior segmentectomy of the liver. A histopathological examination showed a hepatic pseudolymphoma. The patient’s postoperative course was uneventful, and she remains alive without recurrence 5 months after undergoing surgery. In most cases, hepatic pseudolymphoma is preoperatively diagnosed as a malignant tumor and a definite diagnosis is made after resection. It is therefore necessary to consider hepatic pseudolymphoma as a differential diagnosis in patients with hepatic tumors.

  19. Biological imaging in radiation therapy: role of positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nestle, Ursula; Hentschel, Michael; Grosu, Anca-Ligia [Departments of Radiation Oncology, University of Freiburg, Robert Koch Str. 3, 79106 Freiburg (Germany); Weber, Wolfgang [Nuclear Medicine, University of Freiburg, Robert Koch Str. 3, 79106 Freiburg (Germany)], E-mail: ursula.nestle@uniklinik-freiburg.de

    2009-01-07

    In radiation therapy (RT), staging, treatment planning, monitoring and evaluation of response are traditionally based on computed tomography (CT) and magnetic resonance imaging (MRI). These radiological investigations have the significant advantage to show the anatomy with a high resolution, being also called anatomical imaging. In recent years, so called biological imaging methods which visualize metabolic pathways have been developed. These methods offer complementary imaging of various aspects of tumour biology. To date, the most prominent biological imaging system in use is positron emission tomography (PET), whose diagnostic properties have clinically been evaluated for years. The aim of this review is to discuss the valences and implications of PET in RT. We will focus our evaluation on the following topics: the role of biological imaging for tumour tissue detection/delineation of the gross tumour volume (GTV) and for the visualization of heterogeneous tumour biology. We will discuss the role of fluorodeoxyglucose-PET in lung and head and neck cancer and the impact of amino acids (AA)-PET in target volume delineation of brain gliomas. Furthermore, we summarize the data of the literature about tumour hypoxia and proliferation visualized by PET. We conclude that, regarding treatment planning in radiotherapy, PET offers advantages in terms of tumour delineation and the description of biological processes. However, to define the real impact of biological imaging on clinical outcome after radiotherapy, further experimental, clinical and cost/benefit analyses are required. (topical review)

  20. Biological imaging in radiation therapy: role of positron emission tomography.

    Science.gov (United States)

    Nestle, Ursula; Weber, Wolfgang; Hentschel, Michael; Grosu, Anca-Ligia

    2009-01-07

    In radiation therapy (RT), staging, treatment planning, monitoring and evaluation of response are traditionally based on computed tomography (CT) and magnetic resonance imaging (MRI). These radiological investigations have the significant advantage to show the anatomy with a high resolution, being also called anatomical imaging. In recent years, so called biological imaging methods which visualize metabolic pathways have been developed. These methods offer complementary imaging of various aspects of tumour biology. To date, the most prominent biological imaging system in use is positron emission tomography (PET), whose diagnostic properties have clinically been evaluated for years. The aim of this review is to discuss the valences and implications of PET in RT. We will focus our evaluation on the following topics: the role of biological imaging for tumour tissue detection/delineation of the gross tumour volume (GTV) and for the visualization of heterogeneous tumour biology. We will discuss the role of fluorodeoxyglucose-PET in lung and head and neck cancer and the impact of amino acids (AA)-PET in target volume delineation of brain gliomas. Furthermore, we summarize the data of the literature about tumour hypoxia and proliferation visualized by PET. We conclude that, regarding treatment planning in radiotherapy, PET offers advantages in terms of tumour delineation and the description of biological processes. However, to define the real impact of biological imaging on clinical outcome after radiotherapy, further experimental, clinical and cost/benefit analyses are required.

  1. Quality assurance and radiation safety in positron emission tomography

    International Nuclear Information System (INIS)

    Kmetyuk, Ya.V.; Radosh, H.V.; Bezshyyko, O.A.; Golinka-Bezshyyko, L.O.; Kadenko, I.M.; Kazinova, O.A.; Nagai, A.O.

    2012-01-01

    Scientific studies, clinical experience and economic analysis have shown that the positron emission tomography (PET) is clinically and cost effective cancer diagnostics method. Combined PET and computed tomography (PET/CT) has proven clinical utility, particularly in the diagnosis, staging or restaging malignant disease and metastases, surgical planning, radiation therapy planning and evaluation of treatment response. The use of PET/CT has grown substantially in the past few years, with an increasing number of hospitals and installations of PET/CT imaging centers each year. In the same time combination of 2 procedures, each of which impart a radiation dose and, as a result, increases the deleterious influence for health, creates additional radiation safety issues. In these conditions the role of quality assurance (QA) and quality control (QC) programs is getting more and more important. We considered main QA and radiation safety requirements for whole PET technology chain from radio-pharmacy facilities to PET/CT scanning and patient release criteria. All these issues were considered and assessed having the example of PET facilities and technology chain of All-Ukrainian Center for Radiosurgery of the Clinical Hospital 'Feofania'

  2. Neutrino emission from gamma-ray burst fireballs, revised.

    Science.gov (United States)

    Hümmer, Svenja; Baerwald, Philipp; Winter, Walter

    2012-06-08

    We review the neutrino flux from gamma-ray bursts, which is estimated from gamma-ray observations and used for the interpretation of recent IceCube data, from a particle physics perspective. We numerically calculate the neutrino flux for the same astrophysical assumptions as the analytical fireball neutrino model, including the dominant pion and kaon production modes, flavor mixing, and magnetic field effects on the secondary muons, pions, and kaons. We demonstrate that taking into account the full energy dependencies of all spectra, the normalization of the expected neutrino flux reduces by about one order of magnitude and the spectrum shifts to higher energies, where we can pin down the exact origin of the discrepancies by the recomputation of the analytical models. We also reproduce the IceCube-40 analysis for exactly the same bursts and same assumptions and illustrate the impact of uncertainties. We conclude that the baryonic loading of the fireballs, which is an important control parameter for the emission of cosmic rays, can be constrained significantly with the full-scale experiment after about ten years.

  3. Clinical impact of 18F-fluorodeoxyglucose positron emission tomography in the diagnosis of neurological diseases

    International Nuclear Information System (INIS)

    Buck, A.; Kamel, E.

    2002-01-01

    In this review it will be discussed in which neurological disorders positron emission tomography can yield important diagnostic information. Because positron emission tomography is an expensive method indications have to be cleary defined. One important question concerns the differentiation of tumor recurrence and scar due to radiation therapy or an operation. The grading of brain tumors is another application. In HIV patients fluorodeoxyglucose positron emission tomography can separate lymphoma and toxoplasmosis. In the evaluation of dementia positron emission tomography can help to clarify the differential diagnosis. Another important area is the presurgical evaluation of epilepsy patients and patients with cerebrovascular disease in whom a surgical revascularization procedure is planned. In extrapyramidal disorders, positron emission tomography can often help to establish the final diagnosis. (author)

  4. Industrial process gamma tomography. Final report of a coordinated research project 2003-2007

    International Nuclear Information System (INIS)

    2008-05-01

    Gamma computed tomography (CT) is complementary to radiotracer and gamma sealed source techniques largely used for analyzing industrial process units. Relevant target areas for gamma CT applications are generally known. Although the methodology is generic and applicable across broad industrial specimen and facilities, a number of specific items have been identified as the most appropriate target beneficiaries of these applications: distillation columns; packed beds; risers; fluidized beds and other multiphase processing units. These industrial process units present significant technical challenges to CT investigations in terms of the complexity of the multiphase flows that occur in them. In order to address these needs, the IAEA implemented a Coordinated Research Project (CRP) on Industrial Process Gamma Tomography with the overall objective of testing and validating CT techniques for diagnosing industrial multiphase processes. CT laboratories from Argentina, Brazil, Czech Republic, France, Republic of Korea, Malaysia, Norway, Poland, United Kingdom and the United States of America have participated. The specific objectives of the CRP were assessment of the tomographic methods, evaluation of them for investigation of multiphase engineering processes, and design of prototypes of simple CT systems for industrial processing, which can be transferred to other developing countries. The CRP has generated an active network, which also included other groups engaged in the CT field. The round robin test has played an important role in validation of techniques and software. This TECDOC is prepared based on the findings and achievements of the CRP. It is a comprehensive technical report containing valuable information, not readily available in any single publication elsewhere. The participants' reports and software developed by them are compiled in a CD-ROM and attached to the back cover. The guidelines and software packages described in this report can be used as an

  5. A library least-squares approach for scatter correction in gamma-ray tomography

    International Nuclear Information System (INIS)

    Meric, Ilker; Anton Johansen, Geir; Valgueiro Malta Moreira, Icaro

    2015-01-01

    Scattered radiation is known to lead to distortion in reconstructed images in Computed Tomography (CT). The effects of scattered radiation are especially more pronounced in non-scanning, multiple source systems which are preferred for flow imaging where the instantaneous density distribution of the flow components is of interest. In this work, a new method based on a library least-squares (LLS) approach is proposed as a means of estimating the scatter contribution and correcting for this. The validity of the proposed method is tested using the 85-channel industrial gamma-ray tomograph previously developed at the University of Bergen (UoB). The results presented here confirm that the LLS approach can effectively estimate the amounts of transmission and scatter components in any given detector in the UoB gamma-ray tomography system. - Highlights: • A LLS approach is proposed for scatter correction in gamma-ray tomography. • The validity of the LLS approach is tested through experiments. • Gain shift and pulse pile-up affect the accuracy of the LLS approach. • The LLS approach successfully estimates scatter profiles

  6. Effectiveness of lead aprons in positron emission tomography

    International Nuclear Information System (INIS)

    Bezerra Fonseca, R.; Amaral, A.

    2008-01-01

    Full text: In the last two decades, Positron Emission Tomography (PET) has emerged as clinical diagnostic technique, becoming one of the fastest growing imaging tools in modern nuclear medicine. Because 511 keV annihilation photon energy is much higher than the photon with mean energy of 140 keV emitted in Single Photon Computed Tomography (SPECT), medical staff working in PET studies receive a higher dose than those working only with SPECT tracers do. As a result, special attention must be paid to keep radiation exposure as low as reasonably achievable (ALARA principle). Lead equivalent apron is the principal personal protective equipment for technologists occupationally exposed to ionizing radiation in medical procedures and may be an important component in the ALARA program. However, in practices involving PET, 0.5 mm lead equivalent aprons have been used regardless of photon's energy. In this context, this work was designed for evaluating radioprotective effectiveness of such aprons in PET procedures. For this, the operational quantities personal dose equivalent H p (0.07) and H p (10) have been assessed by using MCNP4C code in a model of individual exposure to small source of 511 keV photons, representing the situation of injection of the radiopharmaceutical, in two situations: technologists wearing and not wearing 0.5 mm lead aprons. To represent the technologist a mathematical anthropomorphic phantom was employed, and the simulated source to subject distances varied between 40 to 100 cm, in steps of 10 cm. The results showed no significant differences between the values obtained for H p (10) in the two situations, pointing out that that there is no radioprotective influence of wearing such aprons on PET practices. Compared to simulations without such device, H p (0.07) increased up about 26% when technologist is wearing radioprotective aprons, depending on the source to subject distance. On the basis of this work, 0.5 mm lead equivalent aprons should not be

  7. Astigmatic single photon emission computed tomography imaging with a displaced center of rotation

    International Nuclear Information System (INIS)

    Wang, H.; Smith, M.F.; Stone, C.D.; Jaszczak, R.J.

    1998-01-01

    A filtered backprojection algorithm is developed for single photon emission computed tomography (SPECT) imaging with an astigmatic collimator having a displaced center of rotation. The astigmatic collimator has two perpendicular focal lines, one that is parallel to the axis of rotation of the gamma camera and one that is perpendicular to this axis. Using SPECT simulations of projection data from a hot rod phantom and point source arrays, it is found that a lack of incorporation of the mechanical shift in the reconstruction algorithm causes errors and artifacts in reconstructed SPECT images. The collimator and acquisition parameters in the astigmatic reconstruction formula, which include focal lengths, radius of rotation, and mechanical shifts, are often partly unknown and can be determined using the projections of a point source at various projection angles. The accurate determination of these parameters by a least squares fitting technique using projection data from numerically simulated SPECT acquisitions is studied. These studies show that the accuracy of parameter determination is improved as the distance between the point source and the axis of rotation of the gamma camera is increased. The focal length to the focal line perpendicular to the axis of rotation is determined more accurately than the focal length to the focal line parallel to this axis. copyright 1998 American Association of Physicists in Medicine

  8. Emission tomography with sup(99m)Tc-pyrophosphate in the diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Poeyhoenen, L.; Uusitalo, A.; Virjo, A.

    1985-01-01

    Electrocardiograms (ECG) and enzyme criteria are usually used to confirm the diagnosis of acute myocardial infarction in the case of chest pain. However, ECG is not always diagnostic. Elevated enzyme values may be due to causes other than myocardial infarction. In uncertain cases, the ECG and enzyme criteria can be supplemented by emission tomography, performed with technetium pyrophosphate that will accumulate in the site of infarction. Twenty-nine patients with suspected acute myocardial infarction were studied with emission tomography. Of these 12 had acute transmural infarction. Both enzyme tests and ECG were diagnostic in only 7 of these 12 cases, 4 had positive enzyme tests but a nondiagnostic ECG and in one case neither enzymes nor ECG were diagnostic. In 11 patients the infarcted myocardial area was detected with emission tomography. Six patients had acute nontransmural infarction. Only 2 of these had positive emission tomography. The chest pain was not due to infarction in 11 patients. All these patients had negative emission tomography. The sensitivity of emission tomography was 92% and specificity 100% in transmural acute infarction. In nontransmural infarction the specificity was only 33%. Emission tomography is a valuable diagnostic tool. It may be the decisive method when ECG and enzymes are not diagnostic. Emissin tomography also shows the localization and size of the infarcted area in the myocardium. (orig.)

  9. 3D reconstruction of radioactive sample utilizing gamma tomography

    Science.gov (United States)

    Zoul, David; Zháňal, Pavel

    2018-07-01

    Unique three-dimensional (3D) tomography apparatus was developed and successfully tested at Research Centre Rez, which concentrates at investigation of the degradation of microstructural and mechanical properties of structural materials of nuclear reactors components after a long-term operating exposure. The apparatus allows a 3D view into the interior of low-dimension radioactive samples with a diameter up to several centimeters and a resolution in order of cubic millimeters. It is designed to detect domains with different levels of radioactivity such as cavities, cracks or regions with different chemical composition. The unique collimator design, the use of stepper motors for fine and accurate sample scanning, along with advanced 3D image reconstruction software developed at Research Centre Rez, enables a resolution approaching 1 mm3. Devices working on a similar principle have been used for decades, e.g., in nuclear medicine for the diagnosis of malignant tumors, and are increasingly being applied in the nuclear industry. However, for the first time similar equipment is used for non-destructive testing of low-dimension radioactive samples.

  10. Attenuation correction in emission tomography using the emission data—A review

    Energy Technology Data Exchange (ETDEWEB)

    Berker, Yannick, E-mail: berker@mail.med.upenn.edu; Li, Yusheng [Department of Radiology, University of Pennsylvania, 3620 Hamilton Walk, Philadelphia, Pennsylvania 19104 (United States)

    2016-02-15

    The problem of attenuation correction (AC) for quantitative positron emission tomography (PET) had been considered solved to a large extent after the commercial availability of devices combining PET with computed tomography (CT) in 2001; single photon emission computed tomography (SPECT) has seen a similar development. However, stimulated in particular by technical advances toward clinical systems combining PET and magnetic resonance imaging (MRI), research interest in alternative approaches for PET AC has grown substantially in the last years. In this comprehensive literature review, the authors first present theoretical results with relevance to simultaneous reconstruction of attenuation and activity. The authors then look back at the early history of this research area especially in PET; since this history is closely interwoven with that of similar approaches in SPECT, these will also be covered. We then review algorithmic advances in PET, including analytic and iterative algorithms. The analytic approaches are either based on the Helgason–Ludwig data consistency conditions of the Radon transform, or generalizations of John’s partial differential equation; with respect to iterative methods, we discuss maximum likelihood reconstruction of attenuation and activity (MLAA), the maximum likelihood attenuation correction factors (MLACF) algorithm, and their offspring. The description of methods is followed by a structured account of applications for simultaneous reconstruction techniques: this discussion covers organ-specific applications, applications specific to PET/MRI, applications using supplemental transmission information, and motion-aware applications. After briefly summarizing SPECT applications, we consider recent developments using emission data other than unscattered photons. In summary, developments using time-of-flight (TOF) PET emission data for AC have shown promising advances and open a wide range of applications. These techniques may both remedy

  11. Spectrum of single photon emission computed tomography/computed tomography findings in patients with parathyroid adenomas.

    Science.gov (United States)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Harisankar, Chidambaram Natrajan Balasubramanian; Bhattacharya, Anish; Bhadada, Sanjay

    2011-01-01

    Primary hyperparathyroidism results from excessive parathyroid hormone secretion. Approximately 85% of all cases of primary hyperparathyroidism are caused by a single parathyroid adenoma; 10-15% of the cases are caused by parathyroid hyperplasia. Parathyroid carcinoma accounts for approximately 3-4% of cases of primary disease. Technetium-99m-sestamibi (MIBI), the current scintigraphic procedure of choice for preoperative parathyroid localization, can be performed in various ways. The "single-isotope, double-phase technique" is based on the fact that MIBI washes out more rapidly from the thyroid than from abnormal parathyroid tissue. However, not all parathyroid lesions retain MIBI and not all thyroid tissue washes out quickly, and subtraction imaging is helpful. Single photon emission computed tomography (SPECT) provides information for localizing parathyroid lesions, differentiating thyroid from parathyroid lesions, and detecting and localizing ectopic parathyroid lesions. Addition of CT with SPECT improves the sensitivity. This pictorial assay demonstrates various SPECT/CT patterns observed in parathyroid scintigraphy.

  12. Detecting Metastatic Bladder Cancer Using (18)F-Fluorodeoxyglucose Positron-Emission Tomography/Computed Tomography.

    Science.gov (United States)

    Öztürk, Hakan

    2015-10-01

    The purpose of this study was to retrospectively investigate the contribution of (18)F-fluorodeoxyglucose-positron emission tomography/computed tomography ((18)F-FDG-PET/CT) to detection of metastatic bladder cancer. The present study included 79 patients (69 men and 10 women) undergoing (18)F-FDG-PET/CT upon suspicion of metastatic bladder cancer between July 2007 and April 2013. The mean age was 66.1 years with a standard deviation of 10.7 years (range, 21 to 85 years). Patients were required to fast for 6 hours prior to scanning, and whole-body PET scanning from the skull base to the upper thighs was performed approximately 1 hour after intravenous injection of 555 MBq of (18)F-FDG. Whole body CT scanning was performed in the cranio-caudal direction. FDG-PET images were reconstructed using CT data for attenuation correction. Suspicious recurrent or metastatic lesions were confirmed by histopathology or clinical follow-up. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of (18)F-FDG-PET/CT were 89%, 78%, 90%, 75%, and 86%, respectively. (18)F-FDG-PET/CT can detect metastases with high sensitivity and positive predictive values in patients with metastatic bladder carcinoma.

  13. Brain Positron Emission Tomography-Computed Tomography Gender Differences in Tinnitus Patients.

    Science.gov (United States)

    Shlamkovich, Nathan; Gavriel, Haim; Eviatar, Ephraim; Lorberboym, Mordechay; Aviram, Eliad

    2016-10-01

    Increased metabolism in the left auditory cortex has been reported in tinnitus patients. However, gender difference has not been addressed. To assess the differences in Positron emission tomography-computed tomography (PET-CT) results between the genders in tinnitus patients. Retrospective cohort. Included were patients referred to our clinic between January 2011 and August 2013 who complained of tinnitus and underwent fluorodeoxyglucose (FDG)-PET to assess brain metabolism. Univariate and multivariate nominal logistic regressions were used to evaluate the association between upper temporal gyrus (UTG; right and left) and gender. Included were 140 patients (87 males) with an average age of 52.5 yr (median = 53.1). Bilateral tinnitus was found in 85 patients (60.7%), left sided in 30 (21.4%), and right sided in 21(15%). Increased uptake in the UTG was found in 60% of the patients on either side. Males had a statistically significant increased uptake in the UTG in those with unilateral tinnitus and in the entire population. We present the largest study reported so far on tinnitus patients who have undergone FDG-PET-CT. We found a statistically significant difference between the genders in FDG uptake by the UTG. Further investigations should be undertaken to reveal the etiologies for these differences and to assess different therapeutic protocols according to gender. American Academy of Audiology

  14. Use of Positron Emission Tomography/Computed Tomography in Radiation Treatment Planning for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kezban Berberoğlu

    2016-06-01

    Full Text Available Radiotherapy (RT plays an important role in the treatment of lung cancer. Accurate diagnosis and staging are crucial in the delivery of RT with curative intent. Target miss can be prevented by accurate determination of tumor contours during RT planning. Currently, tumor contours are determined manually by computed tomography (CT during RT planning. This method leads to differences in delineation of tumor volume between users. Given the change in RT tools and methods due to rapidly developing technology, it is now more significant to accurately delineate the tumor tissue. F18 fluorodeoxyglucose positron emission tomography/CT (F18 FDG PET/CT has been established as an accurate method in correctly staging and detecting tumor dissemination in lung cancer. Since it provides both anatomic and biologic information, F18 FDG PET decreases interuser variability in tumor delineation. For instance, tumor volumes may be decreased as atelectasis and malignant tissue can be more accurately differentiated, as well as better evaluation of benign and malignant lymph nodes given the difference in FDG uptake. Using F18 FDG PET/CT, the radiation dose can be escalated without serious adverse effects in lung cancer. In this study, we evaluated the contribution of F18 FDG PET/CT for RT planning in lung cancer.

  15. 18F-FDG positron emission tomography/computed tomography in infective endocarditis.

    Science.gov (United States)

    Salomäki, Soile Pauliina; Saraste, Antti; Kemppainen, Jukka; Bax, Jeroen J; Knuuti, Juhani; Nuutila, Pirjo; Seppänen, Marko; Roivainen, Anne; Airaksinen, Juhani; Pirilä, Laura; Oksi, Jarmo; Hohenthal, Ulla

    2017-02-01

    The diagnosis of infective endocarditis (IE), especially the diagnosis of prosthetic valve endocarditis (PVE) is challenging since echocardiographic findings are often scarce in the early phase of the disease. We studied the use of 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) in IE. Sixteen patients with suspected PVE and 7 patients with NVE underwent visual evaluation of 18 F-FDG-PET/CT. 18 F-FDG uptake was measured also semiquantitatively as maximum standardized uptake value (SUV max ) and target-to-background ratio (TBR). The modified Duke criteria were used as a reference. There was strong, focal 18 F-FDG uptake in the area of the affected valve in all 6 cases of definite PVE, in 3 of 5 possible PVE cases, and in 2 of 5 rejected cases. In all patients with definite PVE, SUV max of the affected valve was higher than 4 and TBR higher than 1.8. In contrast to PVE, only 1 of 7 patients with NVE had uptake of 18 F-FDG by PET/CT in the valve area. Embolic infectious foci were detected in 58% of the patients with definite IE. 18 F-FDG-PET/CT appears to be a sensitive method for the detection of paravalvular infection associated with PVE. Instead, the sensitivity of PET/CT is limited in NVE.

  16. Mycosis fungoides: Positron emission tomography/computed tomography in staging and monitoring the effect of therapy

    International Nuclear Information System (INIS)

    D’Souza, Maria Mathew; D’Souza, Paschal; Sharma, Rajnish; Jaimini, Abhinav; Mondal, Anupam

    2015-01-01

    A 58-year-old woman, diagnosed as a case of mycosis fungoides (MF), underwent [18F]-fluoro-D-glucose positron emission tomography/computed tomography (FDG PET/CT) examination. The study revealed intense FDG uptake in a large ulceroproliferative right thigh lesion, indurated plaques in the chest wall and left thigh, along with multiple sites of cutaneous involvement, axillary and inguinal lymphadenopathy. The patient underwent chemotherapy with CHOP regimen, radiotherapy for the right thigh lesion, along with topical corticosteroids and emollients for the disseminated cutaneous involvement. Repeat [18F]-FDG PET/CT study performed a year later, showed near complete disease regression specifically of the ulceroproliferative lesion and indurated cutaneous plaques, no change in lymphadenopathy, and a subtle diffuse progression of the remaining cutaneous lesions. A multidisciplinary approach to the diagnosis, staging and treatment of MF has long been suggested for optimizing outcomes from management of patients with this disease. This case highlights the potential role of incorporating PET/CT as a single modality imaging technique in the staging and assessment of response to therapy

  17. Technical aspects of positron emission tomography/computed tomography in radiotherapy treatment planning.

    Science.gov (United States)

    Scripes, Paola G; Yaparpalvi, Ravindra

    2012-09-01

    The usage of functional data in radiation therapy (RT) treatment planning (RTP) process is currently the focus of significant technical, scientific, and clinical development. Positron emission tomography (PET) using ((18)F) fluorodeoxyglucose is being increasingly used in RT planning in recent years. Fluorodeoxyglucose is the most commonly used radiotracer for diagnosis, staging, recurrent disease detection, and monitoring of tumor response to therapy (Lung Cancer 2012;76:344-349; Lung Cancer 2009;64:301-307; J Nucl Med 2008;49:532-540; J Nucl Med 2007;48:58S-67S). All the efforts to improve both PET and computed tomography (CT) image quality and, consequently, lesion detectability have a common objective to increase the accuracy in functional imaging and thus of coregistration into RT planning systems. In radiotherapy, improvement in target localization permits reduction of tumor margins, consequently reducing volume of normal tissue irradiated. Furthermore, smaller treated target volumes create the possibility of dose escalation, leading to increased chances of tumor cure and control. This article focuses on the technical aspects of PET/CT image acquisition, fusion, usage, and impact on the physics of RTP. The authors review the basic elements of RTP, modern radiation delivery, and the technical parameters of coregistration of PET/CT into RT computerized planning systems. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. A novel phantom design for emission tomography enabling scatter- and attenuation-''free'' single-photon emission tomography imaging

    International Nuclear Information System (INIS)

    Larsson, S.A.; Johansson, L.; Jonsson, C.; Pagani, M.; Jacobsson, H.

    2000-01-01

    A newly designed technique for experimental single-photon emission tomography (SPET) and positron emission tomography (PET) data acquisition with minor disturbing effects from scatter and attenuation has been developed. In principle, the method is based on discrete sampling of the radioactivity distribution in 3D objects by means of equidistant 2D planes. The starting point is a set of digitised 2D sections representing the radioactivity distribution of the 3D object. Having a radioactivity-related grey scale, the 2D images are printed on paper sheets using radioactive ink. The radioactive sheets can be shaped to the outline of the object and stacked into a 3D structure with air or some arbitrary dense material in between. For this work, equidistantly spaced transverse images of a uniform cylindrical phantom and of the digitised Hoffman rCBF phantom were selected and printed out on paper sheets. The uniform radioactivity sheets were imaged on the surface of a low-energy ultra-high-resolution collimator (4 mm full-width at half-maximum) of a three-headed SPET camera. The reproducibility was 0.7% and the uniformity was 1.2%. Each rCBF sheet, containing between 8.3 and 80 MBq of 99m TcO 4 - depending on size, was first imaged on the collimator and then stacked into a 3D structure with constant 12 mm air spacing between the slices. SPET was performed with the sheets perpendicular to the central axis of the camera. The total weight of the stacked rCBF phantom in air was 63 g, giving a scatter contribution comparable to that of a point source in air. The overall attenuation losses were <20%. A second SPET study was performed with 12-mm polystyrene plates in between the radioactive sheets. With polystyrene plates, the total phantom weight was 2300 g, giving a scatter and attenuation magnitude similar to that of a patient study. With the proposed technique, it is possible to obtain ''ideal'' experimental images (essentially built up by primary photons) for comparison with

  19. Single-photon emission computed tomography/computed tomography in lung cancer and malignant lymphoma.

    Science.gov (United States)

    Schillaci, Orazio

    2006-10-01

    In nuclear oncology, despite the fast-growing diffusion of (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET), single-photon emission computed tomography (SPECT) studies can still play an useful clinical role in several applications. The main limitation of SPECT imaging with tumor-seeking agents is the lack of the structural delineation of the pathologic processes they detect; this drawback sometimes renders SPECT interpretation difficult and can diminish its diagnostic accuracy. Fusion with morphological studies can overcome this limitation by giving an anatomical map to scintigraphic data. In the past, software-based fusion of independently performed SPECT and CT images proved to be time-consuming and impractical for routine use. The recent development of dual-modality integrated imaging systems that provide functional (SPECT) and anatomical (CT) images in the same scanning session, with the acquired images coregistered by means of the hardware, has opened a new era in this field. The first reports indicate that SPECT/CT is very useful in cancer imaging because it is able to provide further information of clinical value in several cases. In SPECT, studies of lung cancer and malignant lymphomas using different radiopharmaceutical, hybrid images are of value in providing the correct localization of tumor sites, with a precise detection of the involved organs, and the definition of their functional status, and in allowing the exclusion of disease in sites of physiologic tracer uptake. Therefore, in lung cancer and lymphomas, hybrid SPECT/CT can play a role in the diagnosis of the primary tumor, in the staging of the disease, in the follow-up, in the monitoring of therapy, in the detection of recurrence, and in dosimetric estimations for target radionuclide therapy.

  20. Retroperitoneal Endometriosis: A Possible Cause of False Positive Finding at 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography

    International Nuclear Information System (INIS)

    Maffione, Anna Margherita; Panzavolta, Riccardo; Lisato, Laura Camilla; Ballotta, Maria; D'Isanto, Mariangela Zanforlini; Rubello, Domenico

    2015-01-01

    Endometriosis is a frequent and clinically relevant problem in young women. Laparoscopy is still the gold standard for the diagnosis of endometriosis, but frequently both morphologic and functional imaging techniques are involved in the diagnostic course before achieving a conclusive diagnosis. We present a case of a patient affected by infiltrating retroperitoneal endometriosis falsely interpreted as a malignant mass by contrast-enhanced magnetic resonance imaging and 18 F-fluorodeoxyglucose positron emission tomography/computed tomography

  1. Utility of fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography in a child with chronic granulomatous disease

    International Nuclear Information System (INIS)

    Garg, Gunjan; DaSilva, Raphaella; Bhalakia, Avni; Milstein, David M.

    2016-01-01

    We report the fluorodeoxyglucose positron emission tomography/computed tomography (FDG - PET/CT) findings in an 11-month-old boy with suspected milk protein allergy, presented to the hospital with 2-month history of fever of unknown origin and failure to thrive. It showed FDG avid lymphadenopathy above and below the diaphragm and splenic focus, which could represent diffuse inflammatory process or lymphoma. Subsequent jejunal biopsy showed non-necrotizing granulomas

  2. Head and neck: normal variations and benign findings in FDG positron emission tomography/computed tomography imaging.

    Science.gov (United States)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-04-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. EEG, transmission computed tomography, and positron emission tomography with fluorodeoxyglucose 18F. Their use in adults with gliomas

    International Nuclear Information System (INIS)

    Newmark, M.E.; Theodore, W.H.; Sato, S.; De La Paz, R.; Patronas, N.; Brooks, R.; Jabbari, B.; Di Chiro, G.

    1983-01-01

    We evaluated the relationship between findings from EEG, transmission computed tomography (CT), and positron emission tomography in 23 adults with gliomas. The cortical metabolic rate was suppressed in patients with and without focal slowing. Focal delta activity was not related to involvement of gray or white matter. Rhythmic delta activity and focal attenuation of background amplitude on EEG, however, were correlated with involvement of the thalamus

  4. Patterns of brown fat uptake of 18F-fluorodeoxyglucose in positron emission tomography/computed tomography scan

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Bhattacharya, Anish; Mittal, Bhagwant Rai

    2015-01-01

    Fluorodeoxyglucose (FDG) positron emission tomography (PET) has become the common imaging modality in oncological practice. FDG uptake is seen in brown adipose tissue in a significant number of patients. Recognizing the uptake patterns is important for optimal FDG PET interpretation. The introduction of PET/computed tomography (PET/CT) revolutionized PET imaging, bringing much-needed anatomical information. Careful review and correlation of FDG PET images with anatomical imaging should be performed to characterize accurately any lesion having high FDG uptake

  5. Promising role of single photon emission computed tomography/computed tomography in Meckel's scan

    International Nuclear Information System (INIS)

    Jain, Anurag; Chauhan, MS; Pandit, AG; Kumar, Rajeev; Sharma, Amit

    2012-01-01

    Meckel's scan is a common procedure performed in nuclear medicine. Single-photon emission computed tomography/computed tomography (SPECT/CT) in a suspected case of heterotopic location of gastric mucosa can increase the accuracy of its anatomic localization. We present two suspected cases of Meckel's diverticulum in, which SPECT/CT co-registration has helped in better localization of the pathology

  6. In Vivo Treatment Sensitivity Testing With Positron Emission Tomography/Computed Tomography After One Cycle of Chemotherapy for Hodgkin Lymphoma

    DEFF Research Database (Denmark)

    Hutchings, Martin; Kostakoglu, Lale; Zaucha, Jan Maciej

    2014-01-01

    PURPOSE: Negative [(18)F]fluorodeoxyglucose (FDG) -positron emission tomography (PET)/computed tomography (CT) after two cycles of chemotherapy indicates a favorable prognosis in Hodgkin lymphoma (HL). We hypothesized that the negative predictive value would be even higher in patients responding....... In the absence of precise pretherapeutic predictive markers, PET1 is the best method for response-adapted strategies designed to select patients for less intensive treatment....

  7. Trails on 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Leading to Diagnosis of Testicular Adrenal Rest Tumor.

    Science.gov (United States)

    Kashyap, Raghava

    2018-01-01

    Testicular adrenal rest tumors (TARTs) are secondary to hypertrophy of adrenal rest cells in the rete testis in settings of hypersecretion of androgens. We present a case of congenital adrenal hyperplasia with TART with clues to the diagnosis on 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT). To the best of our knowledge, this is the first reported case on the role of 18 F-FDG PET/CT in TART.

  8. Gamma-emissions of some meteorites and terrestrial rocks. Evaluation of lunar soil radioactivity; Emissions gamma de quelques meteorites et roches terrestres. Evaluation de la radioactivite du sol lunaire

    Energy Technology Data Exchange (ETDEWEB)

    Nordemann, D. [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    The gamma-emissions of some terrestrial rocks and of the following meteorites: Bogou, Eagle-Station, Granes, and Dosso were studied by quantitative low background gamma spectrometry. These measurements and their interpretation lead to the evaluation of the possible gamma-emissions of several models of lunar soils. (author) [French] Les emissions gamma des meteorites Bogou, Eagle-Station, Granes et Dosso et de quelques roches terrestres ont ete etudiees par spectrometrie gamma quantitative a faible mouvement propre. Ces mesures et leur interpretation permettent d'evaluer les principales contributions des emissions gamma du sol lunaire pour des modeles de compositions possibles variees. (auteur)

  9. Gamma-emissions of some meteorites and terrestrial rocks. Evaluation of lunar soil radioactivity; Emissions gamma de quelques meteorites et roches terrestres. Evaluation de la radioactivite du sol lunaire

    Energy Technology Data Exchange (ETDEWEB)

    Nordemann, D [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    The gamma-emissions of some terrestrial rocks and of the following meteorites: Bogou, Eagle-Station, Granes, and Dosso were studied by quantitative low background gamma spectrometry. These measurements and their interpretation lead to the evaluation of the possible gamma-emissions of several models of lunar soils. (author) [French] Les emissions gamma des meteorites Bogou, Eagle-Station, Granes et Dosso et de quelques roches terrestres ont ete etudiees par spectrometrie gamma quantitative a faible mouvement propre. Ces mesures et leur interpretation permettent d'evaluer les principales contributions des emissions gamma du sol lunaire pour des modeles de compositions possibles variees. (auteur)

  10. 18F-fluorodeoxyglucose positron emission tomography in uterine carcinosarcoma

    International Nuclear Information System (INIS)

    Ho, Kung-Chu; Yen, Tzu-Chen; Lai, Chyong-Huey; Wu, Tzu-I; Chang, Ting-Chang; Huang, Huei-Jean; Ng, Koon-Kwan; Lin, Gigin; Wang, Chun-Chieh; Hsueh, Swei

    2008-01-01

    Uterine carcinosarcomas clinically confined to the uterus usually harbor occult metastases. We conducted a pilot study to evaluate the value of 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in uterine carcinosarcoma. Patients with histologically confirmed uterine carcinosarcoma were enrolled. Abdominal and pelvic magnetic resonance imaging (MRI)/whole-body computed tomography (CT) scan, and whole-body 18 F-FDG PET or PET/CT were undertaken for primary staging, evaluating response, and restaging/post-therapy surveillance. The clinical impact of 18 F-FDG PET was determined on a scan basis. A total of 19 patients were recruited and 31 18 F-FDG PET scans (including 8 scans performed on a PET/CT scanner) were performed. Positive impacts of scans were found in 36.8% (7/19) for primary staging, 66.7% (2/3) for monitoring response, and 11.1% (1/9) for restaging/post-therapy surveillance. PET excluded falsely inoperable disease defined by MRI in two patients. Aggressive treatment applying to three patients with PET-defined resectable stage IVB disease seemed futile. Two patients died of disease shortly after salvage therapy restaged by PET. With PET monitoring, one stage IVB patient treated by targeted therapy only was alive with good performance. Using PET did not lead to improvement of overall survival of this series compared with the historical control (n = 35) (P 0.779). The preliminary results suggest that 18 F-FDG PET is beneficial in excluding falsely inoperable disease for curative therapy and in making a decision on palliation for better quality of life instead of aggressive treatment under the guidance of PET. PET seems to have limited value in post-therapy surveillance or restaging after failure. (orig.)

  11. Fluorodeoxyglucose positron emission tomography in pulmonary carcinoid tumors

    International Nuclear Information System (INIS)

    Gasparri, R.; Rezende, G. C.; Brambilla, D.; Petrella, F.; Galetta, D.; Spaggiari, L.; Fazio, N.; Maisonneuve, P.; Travaini, L. L.; Paganelli, G.

    2015-01-01

    The role of fluorodeoxyglucose positron emission tomography (FDG-PET) as an additional investigation to computer tomography for pulmonary carcinoid tumors remains controversial. The aim of this study was to assess the role of FDG-PET for the diagnosis and staging of pulmonary carcinoid tumors. It has been performed a retrospective mono-institutional analysis of data from 97 patients with pathologically confirmed pulmonary carcinoid tumor who had been operated on between July 1998 and April 2009 and had had a preoperative FDG-PET scan performed. Sixty-five (67%) of the 97 tumors were typical (TC) and 32 (33%) atypical (AC) carcinoid tumors. Overall FDG-PET sensitivity was 67% being lower for TC (60%) than for AC (81%) (P=0.04). FDG-PET negative tumors were smaller than FDG-PET positive tumors, with a respective median size of 15 and 17 mm (P=0.02). Median SUVmax for FDG-PET-positive tumors was 4.0 (2.8-5.1) with no difference between TC and AC tumors. Median Ki-67 expression was respectively 4.7% and 3.1% for FDG-PET positive and FDG-PET negative tumors (P=0.05). During a median follow-up of 49 months (interquartile range 30-63 months), 9 patients (4TC, 5AC) developed recurrent disease. Neither SUVmax nor Ki-67 expression resulted associated with disease-free survival. With an overall sensitivity of 67%, FDG-PET has shown to be useful in the preoperative work-up of patients with suspect lung carcinoid tumors. In particular it could have a role in larger tumors. These results warrant a prospective evaluation of FDG-PET in the staging of lung carcinoid tumor.

  12. Nondestructive testing diagnosis for corrosion and welding by means of hydrostatic test and gamma ray tomography

    International Nuclear Information System (INIS)

    Moura, Alex E.; Dantas, Carlos C.; Nery, Marcelo S.; Barbosa, Jose Maria A.; Rolim, Tiago L.; Melo, Silvio B.; Lima, Emerson A.O.

    2013-01-01

    Diagnoses of light and severe corrosion process in steel tubes are carried out and results are presented. The material discontinuity in metallic pieces was investigated and signals from gamma source detection shown defect present or no defect present. Samples taken from street illumination posts were placed in computerized gamma ray scan to investigate corrosion effect. Scanning at three angles 0 deg, 60 deg and 120 deg degrees with five repetitions provide data set sufficient to a statistical analysis. Samples taken from small diameter steel tubes with light corrosion were analyzed too. Comparing corrosion-free samples detection of transmission gamma ray shows that along with diameter reduction a random density distribution takes place with severe corrosive process. The asymmetry induced in sample density provided to be effective for diagnosis of light corrosion by means of straight-line slope obtained in gamma profile. Structural integrity of steel pipes affected by welding process and defect propagation due to Hydrostatic Testing - HT was simulated by numerical finite element method and data comparison with experimental gamma tomography was carried out. Samples of pipes with preexisting defect on the welding region were submitted to hydrostatic tests over working pressure and a correlation between defect degree and structural resistance was evaluated. (author)

  13. Influence of 18F-fluorodeoxyglucose-positron emission tomography on computed tomography-based radiation treatment planning for oesophageal cancer

    International Nuclear Information System (INIS)

    Everitt, C.; Leong, T.

    2006-01-01

    The addition of positron emission tomography (PET) information to CT-based radiotherapy treatment planning has the potential to improve target volume definition through more accurate localization of the primary tumour and involved regional lymph nodes. This case report describes the first patient enrolled to a prospective study evaluating the effects of coregistered positron emission tomography/CT images on radiotherapy treatment planning for oesophageal cancer. The results show that if combined positron emission tomography/CT is used for radiotherapy treatment planning, there may be alterations to the delineation of tumour volumes when compared to CT alone. For this patient, a geographic miss of tumour would have occurred if CT data alone were used for radiotherapy planning Copyright (2006) Blackwell Publishing Asia Pty Ltd

  14. Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series.

    Science.gov (United States)

    Bartoletti, Michele; Tumietto, Fabio; Fasulo, Giovanni; Giannella, Maddalena; Cristini, Francesco; Bonfiglioli, Rachele; Raumer, Luigi; Nanni, Cristina; Sanfilippo, Silvia; Di Eusanio, Marco; Scotton, Pier Giorgio; Graziosi, Maddalena; Rapezzi, Claudio; Fanti, Stefano; Viale, Pierluigi

    2014-01-13

    The diagnosis of prosthetic valve endocarditis is challenging. The gold standard for prosthetic valve endocarditis diagnosis is trans-esophageal echocardiography. However, trans-esophageal echocardiography may result in negative findings or yield images difficult to differentiate from thrombus in patients with prosthetic valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission tomography is a potentially promising diagnostic tool for several infectious conditions and it has also been employed in patients with prosthetic valve endocarditis but data are still scant. We reviewed the charts of 6 patients with prosthetic aortic valves evaluated for suspicion of prosthetic valve endocarditis, at two different hospital, over a 3-year period. We found 3 patients with early-onset PVE cases and blood cultures yielding Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus lugdunensis, respectively; and 3 late-onset cases in the remaining 3 patients with isolation in the blood of Streptococcus bovis, Candida albicans and P. aeruginosa, respectively. Initial trans-esophageal echocardiography was negative in all the patients, while fluorodeoxyglucose positron emission tomography showed images suspicious for prosthetic valve endocarditis. In 4 out of 6 patients valve replacement was done with histology confirming the prosthetic valve endocarditis diagnosis. After an adequate course of antibiotic therapy fluorodeoxyglucose positron emission tomography showed resolution of prosthetic valve endocarditis in all the patients. Our experience confirms the potential role of fluoroseoxyglucose positron emission tomography in the diagnosis and follow-up of prosthetic valve endocarditis.

  15. Positron Emission Tomography (PET) in the oncologic clinical practice

    International Nuclear Information System (INIS)

    Serna M, J.A.; Luviano, C.; Martinez V, D.; Maldonado S, A.

    2005-01-01

    We intended to determine the frequency with that the computer axial tomography (TAC), it was able to visualize the lesions extra neoplasia detected by the PET tomography in patients with fully identified primary malignant neoplasia. (Author)

  16. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography for preoperative lymph node staging in patients undergoing radical cystectomy for bladder cancer: a prospective study.

    Science.gov (United States)

    Hitier-Berthault, Maryam; Ansquer, Catherine; Branchereau, Julien; Renaudin, Karine; Bodere, Françoise; Bouchot, Olivier; Rigaud, Jérôme

    2013-08-01

    The objective of our study was to analyze the diagnostic performance of (18) F-fluorodeoxyglucose positron emission tomography-computed tomography for lymph node staging in patients with bladder cancer before radical cystectomy and to compare it with that of computed tomography. A total of 52 patients operated on between 2005 and 2010 were prospectively included in this prospective, mono-institutional, open, non-randomized pilot study. Patients who had received neoadjuvant chemotherapy or radiotherapy were excluded. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography in addition to computed tomography was carried out for lymph node staging of bladder cancer before radical cystectomy. Lymph node dissection during radical cystectomy was carried out. Findings from (18) F-fluorodeoxyglucose positron emission tomography-computed tomography and computed tomography were compared with the results of definitive histological examination of the lymph node dissection. The diagnostic performance of the two imaging modalities was assessed and compared. The mean number of lymph nodes removed during lymph node dissection was 16.5 ± 10.9. Lymph node metastasis was confirmed on histological examination in 22 cases (42.3%). This had been suspected in five cases (9.6%) on computed tomography and in 12 cases (23.1%) on (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. Sensitivity, specificity, positive predictive value, negative predictive value, relative risk and accuracy were 9.1%, 90%, 40%, 57.4%, 0.91 and 55.7%, respectively, for computed tomography, and 36.4%, 86.7%, 66.7%, 65%, 2.72, 65.4%, respectively, for (18) F-fluorodeoxyglucose positron emission tomography-computed tomography. (18) F-fluorodeoxyglucose positron emission tomography-computed tomography is more reliable than computed tomography for preoperative lymph node staging in patients with invasive bladder carcinoma undergoing radical cystectomy. © 2012 The Japanese

  17. GammaScorpion: mobile gamma-ray tomography system for early detection of basal stem rot in oil palm plantations

    Science.gov (United States)

    Abdullah, Jaafar; Hassan, Hearie; Shari, Mohamad Rabaie; Mohd, Salzali; Mustapha, Mahadi; Mahmood, Airwan Affendi; Jamaludin, Shahrizan; Ngah, Mohd Rosdi; Hamid, Noor Hisham

    2013-03-01

    Detection of the oil palm stem rot disease Ganoderma is a major issue in estate management and production in Malaysia. Conventional diagnostic techniques are difficult and time consuming when using visual inspection, and destructive and expensive when based on the chemical analysis of root or stem tissue. As an alternative, a transportable gamma-ray computed tomography system for the early detection of basal stem rot (BSR) of oil palms due to Ganoderma was developed locally at the Malaysian Nuclear Agency, Kajang, Malaysia. This system produces high quality tomographic images that clearly differentiate between healthy and Ganoderma infected oil palm stems. It has been successfully tested and used to detect the extent of BSR damage in oil palm plantations in Malaysia without the need to cut down the trees. This method offers promise for in situ inspection of oil palm stem diseases compared to the more conventional methods.

  18. Quantified measurement of brain blood volume: comparative evaluations between the single photon emission computer tomography and the positron computer tomography

    International Nuclear Information System (INIS)

    Bouvard, G.; Fernandez, Y.; Petit-Taboue, M.C.; Derlon, J.M.; Travere, J.M.; Le Poec, C.

    1991-01-01

    The quantified measurement of cerebral blood volume is interesting for the brain blood circulation studies. This measurement is often used in positron computed tomography. It's more difficult in single photon emission computed tomography: there are physical problems with the limited resolution of the detector, the Compton effect and the photon attenuation. The objectif of this study is to compare the results between these two techniques. The quantified measurement of brain blood volume is possible with the single photon emission computer tomogragry. However, there is a loss of contrast [fr

  19. Development of portable gamma ray tomography for imaging corrosion under insulation

    International Nuclear Information System (INIS)

    Rasif Mohd Zain; Roslan Yahya

    2009-01-01

    Corrosion under insulation (CUI) on the external wall of steel pipes is a common problem in many types of industrial plants. This is mainly due to the presence of moisture or water in the insulation materials. This type of corrosion can cause failures in areas that are normally of a primary concern to an inspection program. The failures are often the result of localized corrosion and not general wasting over large area. These failures can tee catastrophic in nature at least have an adverse economic effect in terms of downtime and repairs. There are number of techniques used today for CUI investigations. The main ones are profile radiography, pulse eddy current (PEC), ultrasonic spot readings and insulation removal. A new system that has been developed is gamma-ray computer tomography. The system is based on parallel-beam gamma ray absorption technique using NaI(Tl) 1 ' x 1 ' scintillation detectors. This paper describes the development of gamma ray tomography system. (author)

  20. FERMI DISCOVERY OF GAMMA-RAY EMISSION FROM NGC 1275

    International Nuclear Information System (INIS)

    Abdo, A. A.; Ackermann, M.; Ajello, M.; Bechtol, K.; Blandford, R. D.; Bloom, E. D.; Borgland, A. W.; Asano, K.; Baldini, L.; Bellazzini, R.; Bregeon, J.; Brez, A.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Baughman, B. M.; Bonamente, E.; Brigida, M.; Bruel, P.; Burnett, T. H.

    2009-01-01

    We report the discovery of high-energy (E > 100 MeV) γ-ray emission from NGC 1275, a giant elliptical galaxy lying at the center of the Perseus cluster of galaxies, based on observations made with the Large Area Telescope (LAT) of the Fermi Gamma-ray Space Telescope. The positional center of the γ-ray source is only ∼3' away from the NGC 1275 nucleus, well within the 95% LAT error circle of ∼5'. The spatial distribution of γ-ray photons is consistent with a point source. The average flux and power-law photon index measured with the LAT from 2008 August 4 to 2008 December 5 are F γ = (2.10 ± 0.23) x 10 -7 ph (>100 MeV) cm -2 s -1 and Γ = 2.17 ± 0.05, respectively. The measurements are statistically consistent with constant flux during the four-month LAT observing period. Previous EGRET observations gave an upper limit of F γ -8 ph (>100 MeV) cm -2 s -1 to the γ-ray flux from NGC 1275. This indicates that the source is variable on timescales of years to decades, and therefore restricts the fraction of emission that can be produced in extended regions of the galaxy cluster. Contemporaneous and historical radio observations are also reported. The broadband spectrum of NGC 1275 is modeled with a simple one-zone synchrotron/synchrotron self-Compton model and a model with a decelerating jet flow.

  1. Fermi Discovery of Gamma-Ray Emission from NGC 1275

    International Nuclear Information System (INIS)

    Abdo, Aous A.; Ackermann, M.; Ajello, M.; Asano, K.; Baldini, L.; Ballet, J.; Barbiellini, Guido; Bastieri, Denis; Baughman, B.M.; Bechtol, K.; Bellazzini, R.; Blandford, R.D.; Bloom, Elliott D.; Bonamente, E.; Borgland, A.W.; Bregeon, J.; Brez, A.; Brigida, M.; Bruel, P.; Burnett, Thompson H.; Caliandro, G.A.

    2009-01-01

    We report the discovery of high-energy (E > 100 MeV) γ-ray emission from NGC 1275, a giant elliptical galaxy lying at the center of the Perseus cluster of galaxies, based on observations made with the Large Area Telescope (LAT) of the Fermi Gamma-ray Space Telescope. The positional center of the γ-ray source is only ∼3(prime) away from the NGC 1275 nucleus, well within the 95% LAT error circle of ∼5(prime). The spatial distribution of γ-ray photons is consistent with a point source. The average flux and power-law photon index measured with the LAT from 2008 August 4 to 2008 December 5 are F γ = (2.10 ± 0.23) x 10 -7 ph (>100 MeV) cm -2 s -1 and Γ = 2.17 ± 0.05, respectively. The measurements are statistically consistent with constant flux during the four-month LAT observing period. Previous EGRET observations gave an upper limit of F γ -8 ph (>100 MeV) cm -2 s -1 to the γ-ray flux from NGC 1275. This indicates that the source is variable on timescales of years to decades, and therefore restricts the fraction of emission that can be produced in extended regions of the galaxy cluster. Contemporaneous and historical radio observations are also reported. The broadband spectrum of NGC 1275 is modeled with a simple one-zone synchrotron/synchrotron self-Compton model and a model with a decelerating jet flow.

  2. Fluorinated tracers for imaging cancer with positron emission tomography

    International Nuclear Information System (INIS)

    Couturier, Olivier; Chatal, Jean-Francois; Luxen, Andre; Vuillez, Jean-Philippe; Rigo, Pierre; Hustinx, Roland

    2004-01-01

    2-[ 18 F]fluoro-2-deoxy-d-glucose (FDG) is currently the only fluorinated tracer used in routine clinical positron emission tomography (PET). Fluorine-18 is considered the ideal radioisotope for PET imaging owing to the low positron energy (0.64 MeV), which not only limits the dose rate to the patient but also results in a relatively short range of emission in tissue, thereby providing high-resolution images. Further, the 110-min physical half-life allows for high-yield radiosynthesis, transport from the production site to the imaging site and imaging protocols that may span hours, which permits dynamic studies and assessment of potentially fairly slow metabolic processes. The synthesis of fluorinated tracers as an alternative to FDG was initially tested using nucleophilic fluorination of the molecule, as performed when radiolabelling with iodine-124 or bromide-76. However, in addition to being long, with multiple steps, this procedure is not recommended for bioactive molecules containing reactive groups such as amine or thiol groups. Radiochemical yields are also often low. More recently, radiosynthesis from prosthetic group precursors, which allows easier radiolabelling of biomolecules, has led to the development of numerous fluorinated tracers. Given the wide availability of 18 F, such tracers may well develop into important routine tracers. This article is a review of the literature concerning fluorinated radiotracers recently developed and under investigation for possible PET imaging in cancer patients. Two groups can be distinguished. The first includes ''generalist'' tracers, i.e. tracers amenable to use in a wide variety of tumours and indications, very similar in this respect to FDG. These are tracers for non-specific cell metabolism, such as protein synthesis, amino acid transport, nucleic acid synthesis or membrane component synthesis. The second group consists of ''specific'' tracers for receptor expression (i.e. oestrogens or somatostatin), cell

  3. Relevance of positron emission tomography (PET) in oncology

    International Nuclear Information System (INIS)

    Weber, W.A.; Avril, N.; Schwaiger, M.

    1999-01-01

    Background: The clinical use of positron emission tomography (PET) for detection and staging of malignant tumors is rapidly increasing. Furthermore, encouraging results for monitoring the effects of radio- and chemotherapy have been reported. Methods: This review describes the technical principles of PET and the biological characteristics of tracers used in oncological research and patient studies. The results of clinical studies published in peer reviewed journals during the last 5 years are summarized and clinical indications for PET scans in various tumor types are discussed. Results and Conclusions: Numerous studies have documented the high diagnostic accuracy of PET studies using the glucose analogue F-18-fluordeoxyglucose (FDG-PET) for detection and staging of malignant tumors. In this field, FDG-PET has been particularly successful in lung cancer, colorectal cancer, malignant lymphoma and melanoma. Furthermore, FDG-PET has often proven to be superior to morphological imaging techniques for differentation of tumor recurrence from scar tissue. Due to the high glucose utilization of normal gray matter radiolabeled amino-acids like C-11-methionine are superior to FDG for detection and delineation of brain tumors by PET. In the future, more specific markers of tumor cell proliferation and gene expression may allow the application of PET not only for dianostic imaging also but for non-invasive biological characterization of malignant tumors and early monitoring of therapeutic interventions. (orig.) [de

  4. Measurement of regional cerebral blood flow by positron emission tomography

    International Nuclear Information System (INIS)

    Herscovitch, P.; Powers, W.J.

    1987-01-01

    The principal advantage of positron emission tomography over other methods for measuring cerebral blood flow stems from the accurate, quantitative three-dimensional measurements of regional brain radioactivity that are possible with this technique. As a result, accurate quantitative measurements of regional cerebral blood flow can be obtained for both superficial and deep cerebral structures. The value of PET for investigating central nervous system physiology and pathology extends far beyond this, however. Through the use of different radiotracers and appropriate mathematical models, PET can be applied to the measurement of a wide variety of physiologic variables. Measurements of rCBF tell only part of the story. Experience with PET and with a variety of other techniques has taught us that rCBF is at times a poor indicator of the metabolic, functional, and biochemical status of cerebral tissue. It is only by understanding the interaction of all of these factors that our understanding of neurologic disease can advance. It is in the investigation of these complex relationships that the real value of PET resides

  5. Analysis of human cerebral functions using positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Shibasaki, Takashi

    1984-01-01

    Positron emission tomography has two major advantages to analyse human cerebral functions in vivo. First, we can see the distribution of a variety of substance in the living (and doing something) human brain. Positron emitters, 11 C, 13 N, 15 O and 18 F, are made by medical cyclotron and are elements of natural substrates or easily tagged to substrate. Second, the distribution of the tracer is calculated to make a quantitative functional map in a reasonable spatial resolution over the entire brain in the same time. Not only cortical areas but also deeper structures show regional cerebral blood flow (rCBF) or local cerebral metabolic rates (LCMRs). Nowadays, PET is put to practical use for determination of mainly rCBF, LCMR for glucose (LCMRsub(glu)), LCMR for oxygen (LCMRsub(o2)) and regional cerebral blood volume (rCBV). There have been many other pilot studies, such as estimation of distribution of given neurotransmitters or modulators in the brain which also confirms the substances' role in the neuronal function, and observation of protein synthesis relating to memory function. (J.P.N.)

  6. European health telematics networks for positron emission tomography

    Science.gov (United States)

    Kontaxakis, George; Pozo, Miguel Angel; Ohl, Roland; Visvikis, Dimitris; Sachpazidis, Ilias; Ortega, Fernando; Guerra, Pedro; Cheze-Le Rest, Catherine; Selby, Peter; Pan, Leyun; Diaz, Javier; Dimitrakopoulou-Strauss, Antonia; Santos, Andres; Strauss, Ludwig; Sakas, Georgios

    2006-12-01

    A pilot network of positron emission tomography centers across Europe has been setup employing telemedicine services. The primary aim is to bring all PET centers in Europe (and beyond) closer, by integrating advanced medical imaging technology and health telematics networks applications into a single, easy to operate health telematics platform, which allows secure transmission of medical data via a variety of telecommunications channels and fosters the cooperation between professionals in the field. The platform runs on PCs with Windows 2000/XP and incorporates advanced techniques for image visualization, analysis and fusion. The communication between two connected workstations is based on a TCP/IP connection secured by secure socket layers and virtual private network or jabber protocols. A teleconsultation can be online (with both physicians physically present) or offline (via transmission of messages which contain image data and other information). An interface sharing protocol enables online teleconsultations even over low bandwidth connections. This initiative promotes the cooperation and improved communication between nuclear medicine professionals, offering options for second opinion and training. It permits physicians to remotely consult patient data, even if they are away from the physical examination site.

  7. Characterization of time resolved photodetector systems for Positron Emission Tomography

    CERN Document Server

    Powolny, François

    The main topic of this work is the study of detector systems composed of a scintillator, a photodetector and readout electronics, for Positron Emission Tomography (PET). In particular, the timing properties of such detector systems are studied. The first idea is to take advantage of the good timing properties of the NINO chip, which is a fast preamplifier-discriminator developed for the ALICE Time of flight detector at CERN. This chip uses a time over threshold technique that is to be applied for the first time in medical imaging applications. A unique feature of this technique is that it delivers both timing and energy information with a single digital pulse, the time stamp with the rising edge and the energy from the pulse width. This entails substantial simplification of the entire readout architecture of a tomograph. The scintillator chosen in the detector system is LSO. Crystals of 2x2x10mm3 were used. For the photodetector, APDs were first used, and were then replaced by SiPMs to make use of their highe...

  8. Utilisation of spatial and temporal correlations in positron emission tomography

    International Nuclear Information System (INIS)

    Sureau, F.

    2008-06-01

    In this thesis we propose, implement, and evaluate algorithms improving spatial resolution in reconstructed images and reducing data noise in positron emission tomography imaging. These algorithms have been developed for a high resolution tomograph (HRRT) and applied to brain imaging, but can be used for other tomographs or studies. We first developed an iterative reconstruction algorithm including a stationary and isotropic model of resolution in image space, experimentally measured. We evaluated the impact of such a model of resolution in Monte-Carlo simulations, physical phantom experiments and in two clinical studies by comparing our algorithm with a reference reconstruction algorithm. This study suggests that biases due to partial volume effects are reduced, in particular in the clinical studies. Better spatial and temporal correlations are also found at the voxel level. However, other methods should be developed to further reduce data noise. We then proposed a maximum a posteriori de-noising algorithm that can be used for dynamic data to de-noise temporally raw data (sino-grams) or reconstructed images. The a priori modeled the coefficients in a wavelet basis of all the signals without noise (in an image or sinogram). We compared this technique with a reference de-noising method on replicated simulations. This illustrates the potential benefits of our approach of sinogram de-noising. (author)

  9. Positron emission tomography scans on kanji and kana

    International Nuclear Information System (INIS)

    Sakurai, Yasuhisa

    2002-01-01

    We reanalyzed our positron emission tomography (PET) study on reading of Japanese kanji (morphogram) words, kana (phonogram) words and kana nonwords, using Statistical Parametric Mapping (SPM). The basal occipital and occipito-temporal areas were activated in common, among which activity was most pronounced in the fusiform/inferior temporal gyri with kanji and in the inferior occipital gyrus with kana. The results were consistent with the clinical observations that damage to the posterior inferior temporal cortex including the fusiform/inferior temporal gyri causes alexia with agraphia for kanji, whereas damage to the posterior occipital area including the inferior occipital gyrus causes pure alexia for kana. Bases on the present results and the lesion studies, a dual-route hypothesis that modifies Iwata's model of reading about the Japanese language was proposed. That is, the middle occipital gyrus, deep perisylvian temporoparietal cortex and posterior temporal gyrus constitute a dorsal route for reading and process phonology for words, whereas the inferior occipital, fusiform and posterior inferior temporal gyri constitute a ventral route for reading and process orthography and lexico-semantics for words. The ventral route may gain dominance in reading, according as a word is repeatedly presented. (author)

  10. Brain single photon emission computed tomography in neonates

    International Nuclear Information System (INIS)

    Denays, R.; Van Pachterbeke, T.; Tondeur, M.

    1989-01-01

    This study was designed to rate the clinical value of [ 123 I]iodoamphetamine (IMP) or [ 99m Tc] hexamethyl propylene amine oxyme (HM-PAO) brain single photon emission computed tomography (SPECT) in neonates, especially in those likely to develop cerebral palsy. The results showed that SPECT abnormalities were congruent in most cases with structural lesions demonstrated by ultrasonography. However, mild bilateral ventricular dilatation and bilateral subependymal porencephalic cysts diagnosed by ultrasound were not associated with an abnormal SPECT finding. In contrast, some cortical periventricular and sylvian lesions and all the parasagittal lesions well visualized in SPECT studies were not diagnosed by ultrasound scans. In neonates with subependymal and/or intraventricular hemorrhage the existence of a parenchymal abnormality was only diagnosed by SPECT. These results indicate that [ 123 I]IMP or [ 99m Tc]HM-PAO brain SPECT shows a potential clinical value as the neurodevelopmental outcome is clearly related to the site, the extent, and the number of cerebral lesions. Long-term clinical follow-up is, however, mandatory in order to define which SPECT abnormality is associated with neurologic deficit

  11. Automated identification of the lung contours in positron emission tomography

    International Nuclear Information System (INIS)

    Nery, F; Ferreira, N C; Faustino, R; Silva, J Silvestre; Caramelo, F J

    2013-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging technique that permits to analyze, in three dimensions, the physiological processes in vivo. One of the areas where PET has demonstrated its advantages is in the staging of lung cancer, where it offers better sensitivity and specificity than other techniques such as CT. On the other hand, accurate segmentation, an important procedure for Computer Aided Diagnostics (CAD) and automated image analysis, is a challenging task given the low spatial resolution and the high noise that are intrinsic characteristics of PET images. This work presents an algorithm for the segmentation of lungs in PET images, to be used in CAD and group analysis in a large patient database. The lung boundaries are automatically extracted from a PET volume through the application of a marker-driven watershed segmentation procedure which is robust to the noise. In order to test the effectiveness of the proposed method, we compared the segmentation results in several slices using our approach with the results obtained from manual delineation. The manual delineation was performed by nuclear medicine physicians that used a software routine that we developed specifically for this task. To quantify the similarity between the contours obtained from the two methods, we used figures of merit based on region and also on contour definitions. Results show that the performance of the algorithm was similar to the performance of human physicians. Additionally, we found that the algorithm-physician agreement is similar (statistically significant) to the inter-physician agreement.

  12. Application of positron emission tomography in the lung

    International Nuclear Information System (INIS)

    Valind, S.O.; Wollmer, P.E.; Rhodes, C.G.

    1985-01-01

    The early application of positron emission tomography in the lung was mainly concerned with the investigation of the regional volume of the vascular and extravascular compartments, using measurements of fractional blood volume and lung density. However, in addition to its passive role in the exchange of oxygen and carbon dioxide, the lung exerts a number of active, metabolic functions such as the inactivation of circulating vasoactive compounds and the synthesis and release of biologically active substances. Furthermore, many of the pulmonary disorders originate at a cellular or metabolic level, or have metabolic consequences. Many of the substrates of biochemical reactions and the biologically active compounds, or their analogs, can be labeled with positron-emitting radioisotopes without disturbing their biological or biochemical characteristics. In combination with the development of the appropriate physiological and biochemical models, the quantitative measurements possible with PET provide a unique opportunity of regionally studying the metabolic processes of the lung of man in vivo. Hence, a range of different expressions of metabolism and of lung function can be evaluated and their interdependence can be studied regionally

  13. Application of ART to time-coded emission tomography

    International Nuclear Information System (INIS)

    Koral, K.F.; Rogers, W.L.

    1979-01-01

    Devices for single-photon emission tomography currently take projections either in a plane over a full angular range (0-360 0 ) or in a volume with a limited angular range. The planar, pseudo-random, time-coded aperture, in conjunction with an Anger camera, is a device of the limited angular range type. It employs multiple pinholes whose transmission varies as a function of time. Previously, image reconstruction was accomplished by simple back-projection of coefficients obtained by time-correlating pinhole transmission with detector-element count rate, resulting in a low-contrast image. Using the Algebraic Reconstruction Technique (ART) a method is introduced for division of the correlation coefficients into subsets allowing the three-dimensional reconstruction to be accomplished on a minicomputer. Results from simulations and experimental phantom data show that ART improves depth resolution compared to back-projection, that under-relaxation produces better images in the case of noisy data, and that the division of the correlation coefficients into subsets has no effect on quality. The images depict the expected resolution degradation in the direction normal to the detector plane due to the limited angular range of projections but yield quantitative results whose relative values are good, even though attenuation is neglected. (author)

  14. Simultaneous in vivo positron emission tomography and magnetic resonance imaging.

    Science.gov (United States)

    Catana, Ciprian; Procissi, Daniel; Wu, Yibao; Judenhofer, Martin S; Qi, Jinyi; Pichler, Bernd J; Jacobs, Russell E; Cherry, Simon R

    2008-03-11

    Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution of biologically targeted radiotracers with high sensitivity, but images generally lack anatomic context and are of lower spatial resolution. Integration of these technologies permits the acquisition of temporally correlated data showing the distribution of PET radiotracers and MRI contrast agents or MR-detectable metabolites, with registration to the underlying anatomy. An MRI-compatible PET scanner has been built for biomedical research applications that allows data from both modalities to be acquired simultaneously. Experiments demonstrate no effect of the MRI system on the spatial resolution of the PET system and <10% reduction in the fraction of radioactive decay events detected by the PET scanner inside the MRI. The signal-to-noise ratio and uniformity of the MR images, with the exception of one particular pulse sequence, were little affected by the presence of the PET scanner. In vivo simultaneous PET and MRI studies were performed in mice. Proof-of-principle in vivo MR spectroscopy and functional MRI experiments were also demonstrated with the combined scanner.

  15. Positron emission tomography in degenerative disorders of the dopaminergic system

    Energy Technology Data Exchange (ETDEWEB)

    Karbe, H; Holthoff, V; Huber, M; Herholz, K; Wienhard, K; Wagner, R; Heiss, W D [Universitaetsklinik fuer Neurologie und Max-Planck-Institut fuer neurologische Forschung, Koeln (Germany)

    1992-01-01

    21 patients who had Parkinson's disease (PD), PD plus dementia of Alzheimer type (PDAT) or progressive supranuclear palsy (PSP), were studied with positron emission tomography (PET) using ({sup 18}F)-2-fluoro-2-deoxy-D-glucose (FDG). In one patient with strictly unilateral PD side differences in striatal dopa uptake were studied with 6-({sup 18}F)fluoro-L-dopa (F-dopa). In patients with PD PET with FDG did not show any significant change in regional cerebral metabolic rates for glucose (rCMR(Glu)). In PDAT glucose metabolism was generally reduced, the most severe decrease was found in parietal cortex. The metabolic pattern was similar to that typically found in patients with Alzheimer's disease (AD). In the patient with strictly unilateral PD rCMR(Glu) was normal, F-dopa PET, however, revealed a distinct reduction of dopa uptake in the contralateral putamen. In PSP glucose metabolism was significantly decreased in subcortical regions (caudatum, putamen and brainstem) and in frontal cortex. Thus PET demonstrated a clear difference of metabolic pattern between PDAT and PSP. (authors).

  16. Respiratory synchronization for lung tumors exploration by positon emission tomography

    International Nuclear Information System (INIS)

    Grotus, Nicolas

    2009-01-01

    Positron Emission Tomography (PET) is a medical imaging technique that requires several minutes of acquisition to get an image. PET images are thus severely affected by the respiratory motion of the patient, which introduces a blur in the images. Techniques consisting in gating the PET acquisition as a function of the patient respiration exist and reduce the respiratory blur in the PET images. However, these techniques increase the noise in the reconstructed images. The aim of this work was to propose a method for respiratory motion compensation that would not enhance the noise in the PET images, without increasing the acquisition duration nor estimating the deformation field associated with the respiratory motion. We proposed 2 original spatio-temporal (4D) reconstruction algorithms of gated PET images. These 2 methods take advantage of the temporal correlation between the images corresponding to the different breathing phases. The performances of these techniques were evaluated and compared to classic approaches using phantom data and simulated data. The results showed that the 4D reconstructions increase the signal-to-noise ratio compared to the classic reconstructions while maintaining the reduction of the respiratory blur. For a fixed acquisition duration, the 4D reconstructions can thus yield gated images that are almost free of respiratory blur and of the same quality in terms of noise level as the ones obtained without respiratory gating. The clinical feasibility of the proposed techniques was also demonstrated. (author) [fr

  17. Imaging Cellular Proliferation in Prostate Cancer with Positron Emission Tomography

    Directory of Open Access Journals (Sweden)

    Hossein Jadvar

    2015-07-01

    Full Text Available Prostate cancer remains a major public health problem worldwide. Imaging plays an important role in the assessment of disease at all its clinical phases, including staging, restaging after definitive therapy, evaluation of therapy response, and prognostication. Positron emission tomography with a number of biologically targeted radiotracers has been demonstrated to have potential diagnostic and prognostic utility in the various clinical phases of this prevalent disease. Given the remarkable biological heterogeneity of prostate cancer, one major unmet clinical need that remains is the non-invasive imaging-based characterization of prostate tumors. Accurate tumor characterization allows for image-targeted biopsy and focal therapy as well as facilitates objective assessment of therapy effect. PET in conjunction with radiotracers that track the thymidine salvage pathway of DNA synthesis may be helpful to fulfill this necessity. We review briefly the preclinical and pilot clinical experience with the two major cellular proliferation radiotracers, [18F]-3’-deoxy-3’-fluorothymidine and [18F]-2’-fluoro-5-methyl-1-beta-D-arabinofuranosyluracil in prostate cancer.

  18. Iterative concurrent reconstruction algorithms for emission computed tomography

    International Nuclear Information System (INIS)

    Brown, J.K.; Hasegawa, B.H.; Lang, T.F.

    1994-01-01

    Direct reconstruction techniques, such as those based on filtered backprojection, are typically used for emission computed tomography (ECT), even though it has been argued that iterative reconstruction methods may produce better clinical images. The major disadvantage of iterative reconstruction algorithms, and a significant reason for their lack of clinical acceptance, is their computational burden. We outline a new class of ''concurrent'' iterative reconstruction techniques for ECT in which the reconstruction process is reorganized such that a significant fraction of the computational processing occurs concurrently with the acquisition of ECT projection data. These new algorithms use the 10-30 min required for acquisition of a typical SPECT scan to iteratively process the available projection data, significantly reducing the requirements for post-acquisition processing. These algorithms are tested on SPECT projection data from a Hoffman brain phantom acquired with a 2 x 10 5 counts in 64 views each having 64 projections. The SPECT images are reconstructed as 64 x 64 tomograms, starting with six angular views. Other angular views are added to the reconstruction process sequentially, in a manner that reflects their availability for a typical acquisition protocol. The results suggest that if T s of concurrent processing are used, the reconstruction processing time required after completion of the data acquisition can be reduced by at least 1/3 T s. (Author)

  19. Carbon-11-methionine positron emission tomography imaging of chordoma

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hong [Department of Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan); Department of Medical Imaging, Research Center Hospital for Charged Particle Therapy, National Institute of Radiological Sciences, 4-9-1, Anagawa, Inage-ku, 263-8555, Chiba (Japan); Yoshikawa, Kyosan; Tamura, Katsumi; Sagou, Kenji; Kandatsu, Susumu [Clinical Diagnosis Section, National Institute of Radiological Sciences, Chiba (Japan); Tian, Mei; Suhara, Tetsuya; Suzuki, Kazutoshi; Tanada, Shuji [Department of Medical Imaging, National Institute of Radiological Sciences, Chiba (Japan); Tsujii, Hirohiko [Research Center for Charged Particle Therapy, National Institute of Radiological Sciences, Chiba (Japan)

    2004-09-01

    Chordoma is a rare malignant bone tumor that arises from notochord remnants. This is the first trial to investigate the utility of {sup 11}C-methionine (MET) positron emission tomography (PET) in the imaging of chordoma before and after carbon-ion radiotherapy (CIRT). Fifteen patients with chordoma were investigated with MET-PET before and after CIRT and the findings analyzed visually and quantitatively. Tumor MET uptake was evaluated by tumor-to-nontumor ratio (T/N ratio). In 12 (80%) patients chordoma was clearly visible in the baseline MET-PET study with a mean T/N ratio of 3.3{+-}1.7. The MET uptake decreased significantly to 2.3{+-}1.4 after CIRT (P<0.05). A significant reduction in tumor MET uptake of 24% was observed after CIRT. Fourteen (93%) patients showed no local recurrence after CIRT with a median follow-up time of 20 months. This study has demonstrated that MET-PET is feasible for imaging of chordoma. MET-PET could provide important tumor metabolic information for the therapeutic monitoring of chordoma after CIRT. (orig.)

  20. Carbon-11-methionine positron emission tomography imaging of chordoma

    International Nuclear Information System (INIS)

    Zhang, Hong; Yoshikawa, Kyosan; Tamura, Katsumi; Sagou, Kenji; Kandatsu, Susumu; Tian, Mei; Suhara, Tetsuya; Suzuki, Kazutoshi; Tanada, Shuji; Tsujii, Hirohiko

    2004-01-01

    Chordoma is a rare malignant bone tumor that arises from notochord remnants. This is the first trial to investigate the utility of 11 C-methionine (MET) positron emission tomography (PET) in the imaging of chordoma before and after carbon-ion radiotherapy (CIRT). Fifteen patients with chordoma were investigated with MET-PET before and after CIRT and the findings analyzed visually and quantitatively. Tumor MET uptake was evaluated by tumor-to-nontumor ratio (T/N ratio). In 12 (80%) patients chordoma was clearly visible in the baseline MET-PET study with a mean T/N ratio of 3.3±1.7. The MET uptake decreased significantly to 2.3±1.4 after CIRT (P<0.05). A significant reduction in tumor MET uptake of 24% was observed after CIRT. Fourteen (93%) patients showed no local recurrence after CIRT with a median follow-up time of 20 months. This study has demonstrated that MET-PET is feasible for imaging of chordoma. MET-PET could provide important tumor metabolic information for the therapeutic monitoring of chordoma after CIRT. (orig.)

  1. Positron emission tomography: a new paradigm in cancer management

    International Nuclear Information System (INIS)

    Paez Gutierrez, Diana Isabel; De los Reyes, Amelia; Llamas Olier, Augusto

    2007-01-01

    The National Cancer Institute (NCI) is currently building a positron emission tomography facility that will house a cyclotron and a PET fusion scanner. lt should be operational as of december 2007, being a cancer dedicated national referral center, the NCI should provide both positron-emitting radiopharmaceuticals and medical services to institutions and patients nationwide. PET technology provides metabolic information that has been documented to be useful in patient care. The properties of positron decay allow accurate imaging of the in vivo distribution of positron-emitting radiopharmaceuticals. a wide array of positron-emitting radiopharmaceuticals has been used to characterize multiple physiologic and pathologic states. The major clinical PET applications are in cancer patients using fluorine-18 fluorodeoxyglucose (FDG). FDG, an analogue of glucose, accumulates in most tumors in a greater amount than it does in normal tissue. PET is being used in diagnosis and follow-up of several malignancies, and the list of articles supporting its use continues to grow. in this article, the instrumentation aspects of PET are described and most of the clinical applications in oncology are described

  2. European health telematics networks for positron emission tomography

    International Nuclear Information System (INIS)

    Kontaxakis, George; Pozo, Miguel Angel; Ohl, Roland; Visvikis, Dimitris; Sachpazidis, Ilias; Ortega, Fernando; Guerra, Pedro; Cheze-Le Rest, Catherine; Selby, Peter; Pan, Leyun; Diaz, Javier; Dimitrakopoulou-Strauss, Antonia; Santos, Andres; Strauss, Ludwig; Sakas, Georgios

    2006-01-01

    A pilot network of positron emission tomography centers across Europe has been setup employing telemedicine services. The primary aim is to bring all PET centers in Europe (and beyond) closer, by integrating advanced medical imaging technology and health telematics networks applications into a single, easy to operate health telematics platform, which allows secure transmission of medical data via a variety of telecommunications channels and fosters the cooperation between professionals in the field. The platform runs on PCs with Windows 2000/XP and incorporates advanced techniques for image visualization, analysis and fusion. The communication between two connected workstations is based on a TCP/IP connection secured by secure socket layers and virtual private network or jabber protocols. A teleconsultation can be online (with both physicians physically present) or offline (via transmission of messages which contain image data and other information). An interface sharing protocol enables online teleconsultations even over low bandwidth connections. This initiative promotes the cooperation and improved communication between nuclear medicine professionals, offering options for second opinion and training. It permits physicians to remotely consult patient data, even if they are away from the physical examination site

  3. Clinical application of positron emission tomography imaging in urologic tumors

    International Nuclear Information System (INIS)

    Tang Ganghua; Wu Guangyuan

    2007-01-01

    Positron emission tomography (PET) is an advanced noninvasive molecular imaging modality that is being investigated for use in the differentiation, diagnosis, and guiding therapy ora variety of cancer types. FDG PET has the unique clinical value in the differentiation, diagnosis, and monitoring therapy of prostate, such as bladder, renal, and testicle cancer. However, high false-positive and false-negative findings are observed in the detection of these tumors with FDG PET. 11 C-Choline (CH) and 11 C-acetate (AC) can overcome the pitfall of FDG, and appear to be more successful than FGD in imaging prostate cancer and bladder cancer. The short half-life of 11 C prevents the widespread use of CH and AC and 18 F-fluorocholine (FCH) and 18 F-fluoroacetate (FAC) seem to be potential tracers. Potential clinical value of the new PET tracers, such as 3'-deoxy-3'- 18 F-fluorothymidine (FLT), 18 F-fluorodihydrotestosterone (FDHT), and 9-(4- 18 F-3-hydroxymethylbutyl)-guanine( 18 F-FHBG) in the detection of urologic tumors, can deserve further study. (authors)

  4. 67Ga-emission computed tomography in bronchogenic carcinoma

    International Nuclear Information System (INIS)

    Ichiya, Yuichi; Oshiumi, Yoshihiko; Kuwabara, Yasuo; Wada, Makoto; Ayabe, Zenji; Matsuura, Keiichi

    1982-01-01

    Both conventional 67 Ga scintigraphy and 67 Ga emission computed tomography (ECT) were performed in 36 patients with bronchogenic carcinoma to evaluate clinical significance of 67 Ga-ECT as an adjunctive method. Each patient received 111 -- 185 MBq (3 -- 5 mCi) of 67 Ga-citrate intravenously. A rotation #betta# camera (Shimadzu LFOV-E) was used for ECT study, and a #betta# camera (Searle LFOV) was used for conventional scintigraphy. The detectability of 67 Ga scintigraphy with ECT in primary tumors and regional lymph node metastases was compared retrospectively with that of conventional 67 Ga scintigraphy alone. There was little improvement in detection of primary and metastatic lesions by adding 67 Ga-ECT. Only 3 primary tumors were demonstrated more distinctly by 67 Ga-ECT. However, there was no lesion which was detected only by 67 Ga-ECT. Our data indicate that inclusion of 67 Ga-ECT in the routine examination is unnecessary in cases with bronchogenic carcinoma. (author)

  5. Gallium tomoscintigraphic imaging of esophageal cancer using emission computed tomography

    International Nuclear Information System (INIS)

    Hattori, Takao; Nakagawa, Tsuyoshi; Takeda, Kan; Maeda, Hisato; Taguchi, Mitsuo

    1983-01-01

    Emission computed tomography (ECT) was clinically evaluated in 67 Ga imaging of esophageal cancer. ECT system used in this study is equipped with opposed dual large-field-of-view cameras (GCA 70A-S, Toshiba Co.). Data were acquired by rotating the two cameras 180 0 about the longitudinal axis of the patient. Total acquisition time was about 12 minutes. Multiple slices of transaxial, sagittal and coronal sections were reconstructed in a 64 x 64 matrix form using convolution algorithms. In three out of six cases studied the tumor uptake was not detected on conventional images, because the lesion was small, concentration of activity was poor or the lesion activity was overlapped with the neighbouring activities distributed to normal organs such as sternum, vertebra, liver and hilus. On ECT images, by contrast, abnormal uptake of the tumors was definitively detected in all the six cases. ECT imaging was also useful in estimating the effect of treatment by the decrease in 67 Ga concentration. We have devised a special technique to repeat ECT scan with a thin tube filled with 67 Ga solution inserted through the esophagus. By this technique, comparing paired images with and without the tube activity, exact location of the uptake against the esophagus and extraesophageal extension of the disease could be accurately evaluated in a three-dimensional field of view. ECT in gallium scanning is expected to be of great clinical value to elevate the confidence level of diagnosis in detecting, localizing and following up the diseases. (author)

  6. Proceedings of clinical SPECT [single photon emission computed tomography] symposium

    International Nuclear Information System (INIS)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base

  7. European health telematics networks for positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kontaxakis, George [Universidad Politecnica de Madrid, ETSI Telecomunicacion, Madrid 28040 (Spain)]. E-mail: g.kontaxakis@upm.es; Pozo, Miguel Angel [Centro PET Complutense, Madrid 28040 (Spain); Universidad Complutense de Madrid, Instituto Pluridisciplinar, Madrid 28040 (Spain); Ohl, Roland [MedCom Gesellschaft fuer medizinische Bildverarbeitung mbH, Darmstadt 64283 (Germany); Visvikis, Dimitris [U650 INSERM, Lab. du Traitement de L' Information Medicale, University of Brest Occidentale, CHU Morvan, Brest 29609 (France); Sachpazidis, Ilias [Fraunhofer Institute for Computer Graphics, Darmstadt 64283 (Germany); Ortega, Fernando [Fundacion Instituto Valenciano de Oncologia, Valencia 46009 (Spain); Guerra, Pedro [Universidad Politecnica de Madrid, ETSI Telecomunicacion, Madrid 28040 (Spain); Cheze-Le Rest, Catherine [Dept. Medicine Nucleaire, CHU Morvan, Brest 29609 (France); Selby, Peter [MedCom Gesellschaft fuer medizinische Bildverarbeitung mbH, Darmstadt 64283 (Germany); Pan, Leyun [German Cancer Research Centre, Clinical Cooperation Unit Nuclear Medicine, Heidelberg 69120 (Germany); Diaz, Javier [Fundacion Instituto Valenciano de Oncologia, Valencia 46009 (Spain); Dimitrakopoulou-Strauss, Antonia [German Cancer Research Centre, Clinical Cooperation Unit Nuclear Medicine, Heidelberg 69120 (Germany); Santos, Andres [Universidad Politecnica de Madrid, ETSI Telecomunicacion, Madrid 28040 (Spain); Strauss, Ludwig [German Cancer Research Centre, Clinical Cooperation Unit Nuclear Medicine, Heidelberg 69120 (Germany); Sakas, Georgios [MedCom Gesellschaft fuer medizinische Bildverarbeitung mbH, Darmstadt 64283 (Germany); Fraunhofer Institute for Computer Graphics, Darmstadt 64283 (Germany)

    2006-12-20

    A pilot network of positron emission tomography centers across Europe has been setup employing telemedicine services. The primary aim is to bring all PET centers in Europe (and beyond) closer, by integrating advanced medical imaging technology and health telematics networks applications into a single, easy to operate health telematics platform, which allows secure transmission of medical data via a variety of telecommunications channels and fosters the cooperation between professionals in the field. The platform runs on PCs with Windows 2000/XP and incorporates advanced techniques for image visualization, analysis and fusion. The communication between two connected workstations is based on a TCP/IP connection secured by secure socket layers and virtual private network or jabber protocols. A teleconsultation can be online (with both physicians physically present) or offline (via transmission of messages which contain image data and other information). An interface sharing protocol enables online teleconsultations even over low bandwidth connections. This initiative promotes the cooperation and improved communication between nuclear medicine professionals, offering options for second opinion and training. It permits physicians to remotely consult patient data, even if they are away from the physical examination site.

  8. Single-Photon Emission Computed Tomography (SPECT) in childhood epilepsy

    International Nuclear Information System (INIS)

    Gulati, Sheffali; Kalra, Veena; Bal, C.S.

    2000-01-01

    The success of epilepsy surgery is determined strongly by the precise location of the epileptogenic focus. The information from clinical electrophysiological data needs to be strengthened by functional neuroimaging techniques. Single photon emission computed tomography (SPECT) available locally has proved useful as a localising investigation. It evaluates the regional cerebral blood flow and the comparison between ictal and interictal blood flow on SPECT has proved to be a sensitive nuclear marker for the site of seizure onset. Many studies justify the utility of SPECT in localising lesions to possess greater precision than interictal scalp EEG or anatomic neuroimaging. SPECT is of definitive value in temporal lobe epilepsy. Its role in extratemporal lobe epilepsy is less clearly defined. It is useful in various other generalized and partial seizure disorders including epileptic syndromes and helps in differentiating pseudoseizures from true seizures. The need for newer radiopharmaceutical agents with specific neurochemical properties and longer shelf life are under investigation. Subtraction ictal SPECT co-registered to MRI is a promising new modality. (author)

  9. The natural history of misery perfusion in positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Shinji; Fujii, Kiyotaka; Matsushima, Toshio; Fukui, Masashi; Sadoshima, Shouzou; Kuwabara, Yasuo (Kyushu Univ., Fukuoka (Japan). Faculty of Medicine)

    1992-03-01

    This report reviews the natural courses of misery perfusion in 5 patients with atherosclerotic cerebrovascular occlusion diseases. Cases 1 showed partial improvement and Case 2 showed deterioration of misery perfusion on positron emission tomography (PET). These 2 patients did not show any clinical changes during the follow-up periods. Case 3 showed remarkable improvement of misery perfusion during the 2-year follow-ups, but his neurological condition worsened. The EC-IC bypass improved both in PET and clinical symptoms. Case 4 had a stroke at the region of misery perfusion in PET. Case 5 had a lacunar infarction 2 years after the EC-IC bypass on the opposite side. PET taken one month before the stroke did not show any signs of hypoperfusion in the area of the lacunar infarction. Misery perfusion seems not to be a static but a dynamic condition that can develop into cerebral infarction by some hemodynamic stresses. Cerebral cortical or lobar infarction may occur in the region of severe misery perfusion. EC-IC bypass may prevent impending infarction of the cerebral cortex by improving the regional cerebral blood flow. However, EC-CI bypass will not prevent the lacunar infarction of the basal ganglia or internal capsule. (author).

  10. Variation in positron emission tomography use after colon cancer resection.

    Science.gov (United States)

    Bailey, Christina E; Hu, Chung-Yuan; You, Y Nancy; Kaur, Harmeet; Ernst, Randy D; Chang, George J

    2015-05-01

    Colon cancer surveillance guidelines do not routinely include positron emission tomography (PET) imaging; however, its use after surgical resection has been increasing. We evaluated the secular patterns of PET use after surgical resection of colon cancer among elderly patients and identified factors associated with its increasing use. We used the SEER-linked Medicare database (July 2001 through December 2009) to establish a retrospective cohort of patients age ≥ 66 years who had undergone surgical resection for colon cancer. Postoperative PET use was assessed with the test for trends. Patient, tumor, and treatment characteristics were analyzed using univariable and multivariable logistic regression analyses. Of the 39,221 patients with colon cancer, 6,326 (16.1%) had undergone a PET scan within 2 years after surgery. The use rate steadily increased over time. The majority of PET scans had been performed within 2 months after surgery. Among patients who had undergone a PET scan, 3,644 (57.6%) had also undergone preoperative imaging, and 1,977 (54.3%) of these patients had undergone reimaging with PET within 2 months after surgery. Marriage, year of diagnosis, tumor stage, preoperative imaging, postoperative visit to a medical oncologist, and adjuvant chemotherapy were significantly associated with increased PET use. PET use after colon cancer resection is steadily increasing, and further study is needed to understand the clinical value and effectiveness of PET scans and the reasons for this departure from guideline-concordant care. Copyright © 2015 by American Society of Clinical Oncology.

  11. Image-reconstruction algorithms for positron-emission tomography systems

    International Nuclear Information System (INIS)

    Cheng, S.N.C.

    1982-01-01

    The positional uncertainty in the time-of-flight measurement of a positron-emission tomography system is modelled as a Gaussian distributed random variable and the image is assumed to be piecewise constant on a rectilinear lattice. A reconstruction algorithm using maximum-likelihood estimation is derived for the situation in which time-of-flight data are sorted as the most-likely-position array. The algorithm is formulated as a linear system described by a nonseparable, block-banded, Toeplitz matrix, and a sine-transform technique is used to implement this algorithm efficiently. The reconstruction algorithms for both the most-likely-position array and the confidence-weighted array are described by similar equations, hence similar linear systems can be used to described the reconstruction algorithm for a discrete, confidence-weighted array, when the matrix and the entries in the data array are properly identified. It is found that the mean square-error depends on the ratio of the full width at half the maximum of time-of-flight measurement over the size of a pixel. When other parameters are fixed, the larger the pixel size, the smaller is the mean square-error. In the study of resolution, parameters that affect the impulse response of time-of-flight reconstruction algorithms are identified. It is found that the larger the pixel size, the larger is the standard deviation of the impulse response. This shows that small mean square-error and fine resolution are two contradictory requirements

  12. Gamma-ray emission from 80-86As isotopes

    International Nuclear Information System (INIS)

    Kratz, J.V.; Franz, H.; Kaffrell, N.; Hermann, G.

    1975-01-01

    Activities of 80-86 As were produced in (n,p) reactions on stable selenium nuclei as fission products, and via β - decay from their precursors. To separate arsenic and germanium from fission product mixtures, rapid chemical separations were applied. Gamma-ray emission from arsenic isotopes was studied in γ-singles and γγ coincidence experiments. Partial decay schemes are proposed for 34sec 81 As, 14.0sec and 19.1sec 82 As, 13.3sec 83 As and 5.3sec 84 As. The delayed-neutron branch in the decay of 2.05sec 85 As was shown to preferentially populate several excited levels in 84 Se while the ground state of 84 Se is fed to 29% only. The systematics of low-lying levels in doubly even selenium isotopes is extended up to mass number 86. Discontinuities in the systematics at N=48 are interpreted as an indication of a soft character of the nucleus 82 Se. (Auth.)

  13. Role of Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Diagnostic Evaluation of Carcinoma Urinary Bladder: Comparison with Computed Tomography

    International Nuclear Information System (INIS)

    Chakraborty, Dhritiman; Mittal, Bhagwant Rai; Kashyap, Raghava; Mete, Utham Kumar; Narang, Vikram; Das, Ashim; Bhattacharya, Anish; Khandelwal, Niranjan; Mandal, Arup K.

    2014-01-01

    Bladder carcinoma is the most frequent tumor of the urinary tract and accounts 7% of all malignancies in men and 2% of all malignancies in women. This retrospective study was carried out to assess the diagnostic utility of F18-fludeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) in the imaging evaluation of bladder carcinoma. Seventy-seven consecutive patients diagnosed to have carcinoma urinary bladder referred for F18-FDG PET/CT were included in this study. Thirty-four patients were for initial staging after transurethral biopsy and remaining 43 patients were for restaging. All patients also underwent CT scan of the abdomen and pelvis. PET/CT findings were correlated with diagnostic CT scan and histopathological findings. In 30 of the 34 patients for initial staging, both PET/CT and CT confirmed the primary lesion in the bladder. Histopathology report was available in 23 patients. Lymph nodes FDG uptake reported to be metastatic in 10/23 patients while CT detected lymph node metastasis in 12 patients. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy have been calculated to be 87.5%, 80%, 70%, 92%, 82% for PET/CT and 66%, 57%, 50%, 72%, 60% for CT respectively. PET/CT detected metastatic disease in 8 patients whereas CT detected in 4 patients. Of the 43 patients for restaging, local recurrence was detected in 24 patients on both PET/CT and CT. Histopathology report was available in 17 patients. Sensitivity, specificity, PPV, NPV and accuracy were 85%, 60%, 60%, 85%, 70% for PET/CT and 80%, 50%, 40%, 85%, 58% for CT respectively. Nineteen patients were detected to have metastatic disease by PET/CT, whereas CT detected metastases in 11 patients. F-18 FDG PET/CT is a very useful modality in pre-operative staging and monitoring after surgery, chemotherapy or radiotherapy of patients with carcinoma urinary bladder

  14. Physical factors affecting single photon emission computed tomography (SPECT) applied in nuclear medicine

    International Nuclear Information System (INIS)

    Farag, H.I.; Khalil, W.A.; Hassan, R.A.

    2003-01-01

    many physical factors degrade single photon emission computed tomography (SPECT) images both qualitatively and quantitatively. Physical properties important for the assessment of the potential of emission computed tomography implemented by collimated detector systems include sensitivity, statistical and angular sampling requirements, attenuation compensation, resolution, uniformity, and multisection design constraints. SPECT has highlighted the used to improve gamma camera performance. Flood field nonuniformity is translated into tomographic the need to improve gamma camera performance. Flood field nonuniformity is translated into tomographic images as major artifacts because it distorts the data obtained at each projection. Also, poor energy resolution translates directly into degraded spatial resolution through reduced ability to reject scattered photons on the basic of pluses height analysis. The aim of this work is study the different and most important acquisition and processing parameters, which affect the quality of the SPECT images. The present study investigates the various parameters effecting SPECT images and experimental results demonstrate that: daily uniformity checks and evaluation are essential to ensure that the SPECT system is working properly. The Core used in the reconstruction process could be correct to avoid data misalignment. 60 mumblers of views gave the best image quality, rather than 20 or 30 views. Time per view (TPV) 30 or 20 sec gave a good image quality, rather than high-resolution collimator, is recommended in order to provide good spatial resolution. On the other hand patient motion could cause serious reconstruction artifacts. A cine display is recommended to identify movement artifacts. In the case of matrix size, matrix 128x128 give the best resolution than matrix 64x64. Energy window width, 15% compared with the standard 20% improved the resolution. Butter worth filter (cut off 0.57 cyc/cm with order 6 ) give the best resolution

  15. Use of Computed Tomography and Positron Emission Tomography/Computed Tomography for Staging of Local Extent in Patients With Malignant Pleural Mesothelioma

    OpenAIRE

    Frauenfelder, Thomas; Kestenholz, Peter; Hunziker, Roger; Nguyen, Thi Dan Linh; Fries, Martina; Veit-Haibach, Patrick; Husmann, Lars; Stahel, Rolf; Weder, Walter; Opitz, Isabelle

    2015-01-01

    PURPOSE The objective of this study was to determine the diagnostic value of computed tomography (CT) and positron emission tomography (PET)/CT for staging of malignant pleural mesothelioma (MPM) in patients undergoing induction chemotherapy. METHODS Sixty-two patients (median age, 61 years; female: n = 9) with proven MPM underwent CT after induction chemotherapy. Of these, 28 underwent additional PET/CT. Extrapleural pneumonectomy was performed for pathological TNM staging. Clinical TNM s...

  16. Roles of computed tomography and [18F]fluorodeoxyglucose-positron emission tomography/computed tomography in the characterization of multiple solitary solid lung nodules

    OpenAIRE

    Travaini, LL; Trifirò, G; Vigna, PD; Veronesi, G; De Pas, TM; Spaggiari, L; Paganelli, G; Bellomi, M

    2012-01-01

    The purpose of this study is to compare the performance of multidetector computed tomography (CT) and positron emission tomography/CT (PET/CT) with [18F]fluorodeoxyglucose in the diagnosis of multiple solitary lung nodules in 14 consecutive patients with suspicious lung cancer. CT and PET/CT findings were reviewed by a radiologist and nuclear medicine physician, respectively, blinded to the pathological diagnoses of lung cancer, considering nodule size, shape, and location (CT) and maximum st...

  17. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    Energy Technology Data Exchange (ETDEWEB)

    Yeung, Timothy P C [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Yartsev, Slav [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Lee, Ting-Yim [Robarts Research Institute, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Imaging, The University of Western Ontario, London Health Sciences Centre, Victoria Hospital, Ontario, Canada, N6A 5W9 (Australia); Lawson Health Research Institute, St. Joseph' s Health Care London, Ontario, Canada, N6A 4V2 (Canada); Wong, Eugene [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Physics and Astronomy, The University of Western Ontario, Ontario, Canada, N6A 3K7 (Canada); He, Wenqing [Department of Statistical and Actuarial Sciences, The University of Western Ontario, Ontario, Canada, N6A 5B7 (Canada); Fisher, Barbara; VanderSpek, Lauren L [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Macdonald, David [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada); Department of Clinical Neurological Sciences, The University of Western Ontario, London Health Sciences Centre, University Hospital, Ontario, Canada, N6A 5A5 (Canada); Bauman, Glenn, E-mail: glenn.bauman@lhsc.on.ca [London Regional Cancer Program, London Health Sciences Centre, Ontario, Canada, N6A 4L6 (Canada); Department of Medical Biophysics, The University of Western Ontario, Ontario, Canada, N6A 5C1 (Canada); Department of Oncology, The University of Western Ontario, London Health Sciences Centre, London Regional Cancer Program, Ontario, Canada, N6A 4L6 (Canada)

    2014-02-15

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity.

  18. Role of positron emission tomography-computed tomography in endometrial cancer

    Science.gov (United States)

    Erdemoğlu, Evrim; Çerçi, Sevim Süreyya; Erdemoğlu, Ebru; Yalçın, Yakup; Tatar, Burak

    2017-01-01

    Objective: The efficacy of preoperative 18F-fluoro-D-glucose (18F-FDG) positron emission tomography-computed tomography (PET-CT) in endometrium cancer is controversial. We examined the efficacy of PET-CT and the association between maximum standardized uptake value (SUVmax) and prognostic factors in endometrial cancer. Materials and Methods: Thirty patients with endometrial cancer underwent preoperative 18F-FDG/PET-CT. The patients were treated with abdominal hysterectomy with bilateral salpingo-oophorectomy, and bilateral systemic pelvic lymphadenectomy was planned for all patients; paraaortic lymphadenectomy was performed in patients with intermediate and high risk. Tumor histology, grade, depth of myometrial invasion, maximum tumor diameter, lymphovascular invasion, nodal status, and ovarian/adnexal metastases were recorded. Results: The mean primary tumor diameter was reported smaller in PET-CT and the effect size of PET-CT was -0.60. The kappa value was 0.06 for myometrial invasion. Pelvic lymph node metastasis was reported in 22.2% of patients in PET-CT. However, 3.7% of patients had pelvic lymph node metastasis. The kappa value for pelvic lymph node metastasis was 0.23, and sensitivity, specificity, and positive and negative predictive values were 100%, 80.7%, 16.6%, and 100%, respectively. Paraaortic lymph node metastasis in PET-CT was suspected in 10%. However, paraaortic lymph node metastasis was found in 6.7% in histopathologic analyses. The kappa value was 0.15. The sensitivity, specificity, and positive and negative predictive values of PET-CT for detecting paraaortic lymph node metastases were 100%, 93.7%, 66.6%, and 100%, respectively. Myometrial invasion and tumor diameter were the only important prognostic factors affecting SUVmax. Conclusion: According to our results, PET-CT has a limited role and diagnostic efficacy in endometrial cancer. The indications of FDG/PET-CT in endometrium cancer should be studied further and revised. PMID:29379661

  19. Positron emission tomography combined with computed tomography for diagnosis of synchronous and metachronous tumors

    International Nuclear Information System (INIS)

    Zlatareva, D.; Garcheva, M.; Hadjiiska, V.

    2013-01-01

    Full text: Introduction: Positron emission tomography combined computed tomography (PET/CT) has proved to be the method of choice in oncology for diagnosis and staging, planning and determining the effect of treatment. Aim of the study was to determine the diagnostic capabilities of PET/CT for the detection of synchronous and metachronous tumors. Materials and Methods: The study was conducted with 18F FDG on Discovery, GE Healthcare under standard protocol. 18F FDG is dosed per kg body weight applying before a meal in blood sugar within reference values. The survey was conducted 60 min after application, in addition to visual assessment using quantitative indicators. For a period of a year (2012) 1408 patients were studied. In 11 (2 men, 9 women) of them synchronous and metachronous unsuspected tumors were found. Results: The most common as the second tumors are found processes in the head and neck, followed by lung cancer and colorectal cancer. In four of the cases operational or histological verification was made. In others cases due to refusal or advanced disease indications for systemic therapy the verification wasn't made. Diagnosis of the second tumor has changed the approach to patients as the therapeutic effect was detected at 3 patients over a period of nine months by repeated PET/CT study. Conclusion: The hybrid PET/CT, combining information about structural changes (CT) and metabolic changes (PET) plays an important role in the diagnosis of synchronous and metachronous tumors. This can significantly change the therapeutic management and prognosis of patients

  20. Positron emission tomography/computed tomography--imaging protocols, artifacts, and pitfalls.

    Science.gov (United States)

    Bockisch, Andreas; Beyer, Thomas; Antoch, Gerald; Freudenberg, Lutz S; Kühl, Hilmar; Debatin, Jörg F; Müller, Stefan P

    2004-01-01

    There has been a longstanding interest in fused images of anatomical information, such as that provided by computed tomography (CT) or magnetic resonance imaging (MRI) systems, with biological information obtainable by positron emission tomography (PET). The near-simultaneous data acquisition in a fixed combination of a PET and a CT scanner in a combined PET/CT imaging system minimizes spatial and temporal mismatches between the modalities by eliminating the need to move the patient in between exams. In addition, using the fast CT scan for PET attenuation correction, the duration of the examination is significantly reduced compared to standalone PET imaging with standard rod-transmission sources. The main source of artifacts arises from the use of the CT-data for scatter and attenuation correction of the PET images. Today, CT reconstruction algorithms cannot account for the presence of metal implants, such as dental fillings or prostheses, properly, thus resulting in streak artifacts, which are propagated into the PET image by the attenuation correction. The transformation of attenuation coefficients at X-ray energies to those at 511 keV works well for soft tissues, bone, and air, but again is insufficient for dense CT contrast agents, such as iodine or barium. Finally, mismatches, for example, due to uncoordinated respiration result in incorrect attenuation-corrected PET images. These artifacts, however, can be minimized or avoided prospectively by careful acquisition protocol considerations. In doubt, the uncorrected images almost always allow discrimination between true and artificial finding. PET/CT has to be integrated into the diagnostic workflow for harvesting the full potential of the new modality. In particular, the diagnostic power of both, the CT and the PET within the combination must not be underestimated. By combining multiple diagnostic studies within a single examination, significant logistic advantages can be expected if the combined PET

  1. Relationship of computed tomography perfusion and positron emission tomography to tumour progression in malignant glioma

    International Nuclear Information System (INIS)

    Yeung, Timothy P C; Yartsev, Slav; Lee, Ting-Yim; Wong, Eugene; He, Wenqing; Fisher, Barbara; VanderSpek, Lauren L; Macdonald, David; Bauman, Glenn

    2014-01-01

    Introduction: This study aimed to explore the potential for computed tomography (CT) perfusion and 18-Fluorodeoxyglucose positron emission tomography (FDG-PET) in predicting sites of future progressive tumour on a voxel-by-voxel basis after radiotherapy and chemotherapy. Methods: Ten patients underwent pre-radiotherapy magnetic resonance (MR), FDG-PET and CT perfusion near the end of radiotherapy and repeated post-radiotherapy follow-up MR scans. The relationships between these images and tumour progression were assessed using logistic regression. Cross-validation with receiver operating characteristic (ROC) analysis was used to assess the value of these images in predicting sites of tumour progression. Results: Pre-radiotherapy MR-defined gross tumour; near-end-of-radiotherapy CT-defined enhancing lesion; CT perfusion blood flow (BF), blood volume (BV) and permeability-surface area (PS) product; FDG-PET standard uptake value (SUV); and SUV:BF showed significant associations with tumour progression on follow-up MR imaging (P < 0.0001). The mean sensitivity (±standard deviation), specificity and area under the ROC curve (AUC) of PS were 0.64 ± 0.15, 0.74 ± 0.07 and 0.72 ± 0.12 respectively. This mean AUC was higher than that of the pre-radiotherapy MR-defined gross tumour and near-end-of-radiotherapy CT-defined enhancing lesion (both AUCs = 0.6 ± 0.1, P ≤ 0.03). The multivariate model using BF, BV, PS and SUV had a mean AUC of 0.8 ± 0.1, but this was not significantly higher than the PS only model. Conclusion: PS is the single best predictor of tumour progression when compared to other parameters, but voxel-based prediction based on logistic regression had modest sensitivity and specificity

  2. Enhancement of positron emission tomography-computed tomography image quality using the principle of stochastic resonance

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Sanjay Kumar; Sharma, Punit; Singh, Harmandeep; Patel, Chetan; Sarkar, Kaushik; Kumar, Rakesh; Bal, Chandra Sekhar

    2014-01-01

    Acquisition of higher counts improves visual perception of positron emission tomography-computed tomography (PET-CT) image. Larger radiopharmaceutical doses (implies more radiation dose) are administered to acquire this count in a short time period. However, diagnostic information does not increase after a certain threshold of counts. This study was conducted to develop a post processing method based on principle of “stochastic resonance” to improve visual perception of the PET-CT image having a required threshold counts. PET-CT images (JPEG file format) with low, medium, and high counts in the image were included in this study. The image was corrupted with the addition of Poisson noise. The amplitude of the Poisson noise was adjusted by dividing each pixel by a constant 1, 2, 4, 8, 16, and 32. The best amplitude of the noise that gave best images quality was selected based on high value of entropy of the output image, high value of structural similarity index and feature similarity index. Visual perception of the image was evaluated by two nuclear medicine physicians. The variation in structural and feature similarity of the image was not appreciable visually, but statistically images deteriorated as the noise amplitude increases although maintaining structural (above 70%) and feature (above 80%) similarity of input images in all cases. We obtained the best image quality at noise amplitude “4” in which 88% structural and 95% feature similarity of the input images was retained. This method of stochastic resonance can be used to improve the visual perception of the PET-CT image. This can indirectly lead to reduction of radiation dose

  3. The predictive value of single-photon emission computed tomography/computed tomography for sentinel lymph node localization in head and neck cutaneous malignancy.

    Science.gov (United States)

    Remenschneider, Aaron K; Dilger, Amanda E; Wang, Yingbing; Palmer, Edwin L; Scott, James A; Emerick, Kevin S

    2015-04-01

    Preoperative localization of sentinel lymph nodes in head and neck cutaneous malignancies can be aided by single-photon emission computed tomography/computed tomography (SPECT/CT); however, its true predictive value for identifying lymph nodes intraoperatively remains unquantified. This study aims to understand the sensitivity, specificity, and positive and negative predictive values of SPECT/CT in sentinel lymph node biopsy for cutaneous malignancies of the head and neck. Blinded retrospective imaging review with comparison to intraoperative gamma probe confirmed sentinel lymph nodes. A consecutive series of patients with a head and neck cutaneous malignancy underwent preoperative SPECT/CT followed by sentinel lymph node biopsy with a gamma probe. Two nuclear medicine physicians, blinded to clinical data, independently reviewed each SPECT/CT. Activity within radiographically defined nodal basins was recorded and compared to intraoperative gamma probe findings. Sensitivity, specificity, and negative and positive predictive values were calculated with subgroup stratification by primary tumor site. Ninety-two imaging reads were performed on 47 patients with cutaneous malignancy who underwent SPECT/CT followed by sentinel lymph node biopsy. Overall sensitivity was 73%, specificity 92%, positive predictive value 54%, and negative predictive value 96%. The predictive ability of SPECT/CT to identify the basin or an adjacent basin containing the single hottest node was 92%. SPECT/CT overestimated uptake by an average of one nodal basin. In the head and neck, SPECT/CT has higher reliability for primary lesions of the eyelid, scalp, and cheek. SPECT/CT has high sensitivity, specificity, and negative predictive value, but may overestimate relevant nodal basins in sentinel lymph node biopsy. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  4. Estimation of intersubject variability of cerebral blood flow measurements using MRI and positron emission tomography

    DEFF Research Database (Denmark)

    Henriksen, Otto Mølby; Larsson, Henrik B W; Hansen, Adam E

    2012-01-01

    PURPOSE: To investigate the within and between subject variability of quantitative cerebral blood flow (CBF) measurements in normal subjects using various MRI techniques and positron emission tomography (PET). MATERIALS AND METHODS: Repeated CBF measurements were performed in 17 healthy, young...

  5. Measurement of blood-brain barrier permeability with positron emission tomography in patients with multiple sclerosis

    International Nuclear Information System (INIS)

    Fieschi, C.; Pozzilli, C.; Bernardi, S.; Bozzao, L.; Lenzi, G.L.; Picozzi, P.; Iannotti, F.; Conforti, P.

    1988-01-01

    The purpose of the investigation was to elucidate the role of positron emission tomography using 68 Ga-EDTA in the study of blood-brain barrier abnormalities associated with multiple sclerosis. 14 refs.; 1 figure

  6. Readout of scintillator light with avalanche photodiodes for positron emission tomography

    International Nuclear Information System (INIS)

    Chen, Ruru; Fremout, A.; Tavernier, S.; Bruyndonckx, P.; Clement, D.; Loude, J.-F.; Morel, C.

    1999-01-01

    The noise properties and other relevant characteristics of avalanche photodiodes have been investigated with the perspective of replacing photomultiplier tubes in positron emission tomography. It is clearly demonstrated that they are a valid alternative to photomultiplier tubes in this application

  7. Imaging Atherosclerosis with Hybrid Positron Emission Tomography/Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Ripa, Rasmus Sejersten; Kjær, Andreas

    2015-01-01

    Noninvasive imaging of atherosclerosis could potentially move patient management towards individualized triage, treatment, and followup. The newly introduced combined positron emission tomography (PET) and magnetic resonance imaging (MRI) system could emerge as a key player in this context. Both...

  8. Measurement of regional cerebral glucose utilization in man by positron emission tomography

    International Nuclear Information System (INIS)

    Baron, J.C.

    1986-05-01

    The various methods available for the study of regional cerebral glucose consumption in man by positron emission tomography are described and their applications, limitations and principal physiopathological results are presented [fr

  9. Evaluation of esophageal cancer by positron emission tomography

    International Nuclear Information System (INIS)

    Himeno, Shinji; Yasuda, Seiei; Shimada, Hideo; Tajima, Tomoo; Makuuchi, Hiroyasu

    2002-01-01

    A retrospective study was performed to determine the indications for positron emission tomography (PET) using [ 18 F]fluorodeoxyglucose (FDG) in patients with esophageal cancer, including those with early cancer, and to investigate whether the tumor-to-normal ratio (T/N ratio) could be used as a substitute for the standardized uptake value (SUV). Thirty-six patients were included in the study. Thirty-one patients who had 36 biopsy-proven lesions (35 squamous cell carcinomas and one small cell carcinoma) underwent PET study prior to treatment. PET images were evaluated visually and the relationship between the depth of invasion and the PET findings were examined in 22 lesions of 19 patients from whom specimens were obtained from the primary tumor by surgery or endoscopic mucosal resection. PET results were also compared with computed tomography (CT) and endoscopic ultrasonography (EUS) for detection of regional lymph node metastases in 18 patients who underwent extended lymph node dissection. Five patients underwent PET studies for the detection of recurrence and the PET findings were compared with their CT findings. The T/N ratio and the SUV were calculated for 20 primary tumors. Among the 15 tumors that were pT1b or greater, all 15 were positive on PET and all seven of the lesions confined to the mucosa (Tis or T1a) were negative. The sensitivity, specificity and accuracy of detecting nodal involvement were, respectively, 37.5, 96.1 and 88.3% by CT, 30.8, 88.5 and 81.0% by EUS and 41.7, 100 and 92.2% by PET. More sites of recurrence were detected by PET than by CT. There was no statistically significant correlation between the SUV and the T/N ratio. PET imaging can detect primary esophageal cancer with a depth of invasion of T1b or greater, but Tis and T1a tumors are undetectable. PET seems to be more accurate than CT or EUS for diagnosing lymph node metastasis. The T/N ratio cannot be used as a substitute for the SUV. (author)

  10. Measurements of the low-energy gamma-ray continuum emission from the Galactic Center direction

    International Nuclear Information System (INIS)

    Jardim, M.V.A.; Martin, I.M.; Jardim, J.O.D.

    1982-07-01

    The measurement of the gamma-ray continuum emission from the Galactic Center (GC) can provide us information about the physical processes taking place there at the site of emission. Using the data obtained with a balloon-borne gamma-ray telescope to measure gamma-rays in the energy interval between 0,3 and 3 MeV, which was launched on March 28, 1980 from Cachoeira Paulista (SP), we calculeted two points for the continuum spectrum in the range between 0,34 and 0,67 MeV. The points are related to the GC emission radiated in the longitude interval - 31 0 0 . The measurements are compatible with the observations in 1969 and 1972 by Haymes et alii and Johnson, respectively. The power law spectrum suggests that the main component for the gamma-ray continuum emission below 10 MeV is dominated by the bremsstrahlung due to relativistic electrons. (Author) [pt

  11. Computed tomography angiography and perfusion to assess coronary artery stenosis causing perfusion defects by single photon emission computed tomography

    DEFF Research Database (Denmark)

    Rochitte, Carlos E; George, Richard T; Chen, Marcus Y

    2014-01-01

    AIMS: To evaluate the diagnostic power of integrating the results of computed tomography angiography (CTA) and CT myocardial perfusion (CTP) to identify coronary artery disease (CAD) defined as a flow limiting coronary artery stenosis causing a perfusion defect by single photon emission computed...... emission computed tomography (SPECT/MPI). Sixteen centres enroled 381 patients who underwent combined CTA-CTP and SPECT/MPI prior to conventional coronary angiography. All four image modalities were analysed in blinded independent core laboratories. The prevalence of obstructive CAD defined by combined ICA...... tomography (SPECT). METHODS AND RESULTS: We conducted a multicentre study to evaluate the accuracy of integrated CTA-CTP for the identification of patients with flow-limiting CAD defined by ≥50% stenosis by invasive coronary angiography (ICA) with a corresponding perfusion deficit on stress single photon...

  12. Fluorodeoxyglucose positron emission tomography/computed tomography findings in a patient with cerebellar mutism after operation in posterior fossa

    Directory of Open Access Journals (Sweden)

    Gonca Kara Gedik

    2017-03-01

    Full Text Available Cerebellar mutism is a transient period of speechlessness that evolves after posterior fossa surgery in children. Although direct cerebellar and brain stem injury and supratentorial dysfunction have been implicated in the mediation of mutism, the pathophysiological mechanisms involved in the evolution of this kind of mutism remain unclear. Magnetic resonance imaging revealed dentatothalamocortical tract injuries and single photon emission computed tomography showed cerebellar and cerebral hypoperfusion in patients with cerebellar mutism. However, findings with 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT in this group of patients have not been documented previously. In this clinical case, we report a patient who experienced cerebellar mutism after undergoing a posterior fossa surgery. Right cerebellar and left frontal lobe hypometabolism was shown using FDG PET/CT. The FDG metabolism of both the cerebellum and the frontal lobe returned to normal levels after the resolution of the mutism symptoms.

  13. Positron emission tomography: Which indications, which benefits?; Tomographie par emission de positons (TEP): quelles indications, quels benefices?

    Energy Technology Data Exchange (ETDEWEB)

    Chassoux, F. [Ctr Hosp St Anne, Serv Neurochirurg, F-75014 Paris (France); Chassoux, F.; Chiron, C. [CEA, I2BM, Serv Hosp Frederic Joliot, F-91 Orsay (France); Chiron, C. [Hop Necker Enfants Malad, INSERM, U663, F-75015 Paris (France); Chassoux, F.; Chiron, C. [Univ Paris 06, F-75005 Paris (France)

    2008-07-01

    Positron emission tomography (PET) is currently used in the pre-surgical workup for drug-resistant partial epilepsies in addition to MRI. Inter-ictal metabolism is studied in clinical practice using {sup 18}fluoro-desoxy-glucose ({sup 18}FDG). In medial temporal lobe epilepsy (MTLE) associated with hippocampal sclerosis, hypo-metabolism ipsilateral to the epileptogenic focus is found in 70-90% of cases. However, hypo-metabolism is larger than the structural lesion observed on MRI and includes the epileptogenic zone and ictal discharge spread areas. Hypo-metabolism is related to surgical outcome and cognitive disturbances in MTLE. Although the usefulness of PET appears less well-established in extra-temporal lobe epilepsy and in children, its sensitivity may be improved by co-registration and superimposition of PET on MRI at any age. Focal hypo-metabolism can be easily detected by visual analysis, allowing detection of minor gyral abnormalities that may correspond to focal cortical dysplasias. Moreover, in cases of negative MRI, focal hypo-metabolism findings may help invasive monitoring planning and deep electrode placement for SEEG, and finally improve surgical outcome. (authors)

  14. Polarization of the prompt gamma-ray emission from the gamma-ray burst of 6 December 2002.

    Science.gov (United States)

    Coburn, Wayne; Boggs, Steven E

    2003-05-22

    Observations of the afterglows of gamma-ray bursts (GRBs) have revealed that they lie at cosmological distances, and so correspond to the release of an enormous amount of energy. The nature of the central engine that powers these events and the prompt gamma-ray emission mechanism itself remain enigmatic because, once a relativistic fireball is created, the physics of the afterglow is insensitive to the nature of the progenitor. Here we report the discovery of linear polarization in the prompt gamma-ray emission from GRB021206, which indicates that it is synchrotron emission from relativistic electrons in a strong magnetic field. The polarization is at the theoretical maximum, which requires a uniform, large-scale magnetic field over the gamma-ray emission region. A large-scale magnetic field constrains possible progenitors to those either having or producing organized fields. We suggest that the large magnetic energy densities in the progenitor environment (comparable to the kinetic energy densities of the fireball), combined with the large-scale structure of the field, indicate that magnetic fields drive the GRB explosion.

  15. Nonhuman primate positron emission tomography neuroimaging in drug abuse research.

    Science.gov (United States)

    Howell, Leonard Lee; Murnane, Kevin Sean

    2011-05-01

    Positron emission tomography (PET) neuroimaging in nonhuman primates has led to significant advances in our current understanding of the neurobiology and treatment of stimulant addiction in humans. PET neuroimaging has defined the in vivo biodistribution and pharmacokinetics of abused drugs and related these findings to the time course of behavioral effects associated with their addictive properties. With novel radiotracers and enhanced resolution, PET neuroimaging techniques have also characterized in vivo drug interactions with specific protein targets in the brain, including neurotransmitter receptors and transporters. In vivo determinations of cerebral blood flow and metabolism have localized brain circuits implicated in the effects of abused drugs and drug-associated stimuli. Moreover, determinations of the predisposing factors to chronic drug use and long-term neurobiological consequences of chronic drug use, such as potential neurotoxicity, have led to novel insights regarding the pathology and treatment of drug addiction. However, similar approaches clearly need to be extended to drug classes other than stimulants. Although dopaminergic systems have been extensively studied, other neurotransmitter systems known to play a critical role in the pharmacological effects of abused drugs have been largely ignored in nonhuman primate PET neuroimaging. Finally, the study of brain activation with PET neuroimaging has been replaced in humans mostly by functional magnetic resonance imaging (fMRI). There has been some success in implementing pharmacological fMRI in awake nonhuman primates. Nevertheless, the unique versatility of PET imaging will continue to complement the systems-level strengths of fMRI, especially in the context of nonhuman primate drug abuse research.

  16. Proceedings of clinical SPECT (single photon emission computed tomography) symposium

    Energy Technology Data Exchange (ETDEWEB)

    1986-09-01

    It has been five years since the last in-depth American College of Nuclear Physicians/Society of Nuclear Medicine Symposium on the subject of single photon emission computed tomography (SPECT) was held. Because this subject was nominated as the single most desired topic we have selected SPECT imaging as the basis for this year's program. The objectives of this symposium are to survey the progress of SPECT clinical applications that have taken place over the last five years and to provide practical and timely guidelines to users of SPECT so that this exciting imaging modality can be fully integrated into the evaluation of pathologic processes. The first half was devoted to a consideration of technical factors important in SPECT acquisition and the second half was devoted to those organ systems about which sufficient clinical SPECT imaging data are available. With respect to the technical aspect of the program we have selected the key areas which demand awareness and attention in order to make SPECT operational in clinical practice. These include selection of equipment, details of uniformity correction, utilization of phantoms for equipment acceptance and quality assurance, the major aspect of algorithms, an understanding of filtered back projection and appropriate choice of filters and an awareness of the most commonly generated artifacts and how to recognize them. With respect to the acquisition and interpretation of organ images, the faculty will present information on the major aspects of hepatic, brain, cardiac, skeletal, and immunologic imaging techniques. Individual papers are processed separately for the data base. (TEM)

  17. Oxygen-15 labelled water production for positron emission tomography

    International Nuclear Information System (INIS)

    Janus, A.; Sachinidis, J.I.; Chan, J.G.; Tochon-Danguy, H.J.

    1998-01-01

    Full text: Functional imaging using positron emission tomography (PET) and 15 O-labelled compounds is both scientifically and clinically challenging. The short half-life of oxygen-15 (t 1/2 = 2 min) allows for multiple administration to a patient without exceeding acceptable levels of absorbed radiation dose and without excessive delay between administrations. The clinical usefulness of [ 15 O]-labelled water for cerebral blood flow measurements has been well established. Here we report the development and construction of a [ 15 O]water generator based on an earlier design from Hammersmith Hospital, London. The cyclotron produces a continuous flow of [ 15 O]O 2 gas by the irradiation of a natural nitrogen target (1% O 2 in N 2 ) with a 5 MeV deuteron beam, via the nuclear reaction ( 14 N(d,n) 15 O). The radioactive gas is then mixed with 5% hydrogen in nitrogen and piped to the water generator located in the scanner room. The O 2 /N 2 gas mixture is reacted over a palladium catalyst at 1500 deg C to produce [ 15 O]H 2 O vapour. The vapour passes through an exchanger where it diffuses across a semi-permeable membrane (cellulose acetate) into saline solution. At the optimum gas flow- rate of 500 mL/min, more than 95% of the radioactive oxygen is converted to radioactive water. Waste radioactive gas is piped back to the cyclotron vault to decay before release into the atmosphere. The saline solution (0.9% NaCl) is pumped continuously through the system at 6 mL/min with an infusion pump (3M AVI470). The present system has been in operation for more than a year and has been used for clinical evaluation of stroke patients and for brain activation research studies

  18. Study of brain metabolism using positron emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Heiss, W D

    1983-03-21

    Positron emission tomography permits the three-dimensional regional measurement of metabolism and blood flow in the brain. For the determination of cerebral metabolic rates of glucose by PET /sup 18/fluordeoxyglucose is usually applied: cerebral metabolic rate of glucose was found to be 36 to 47 ..mu..mol/100 g/min in the grey matter and 23 to 29 ..mu..mol/100 g/min in the white matter of normal volunteers. During physiologic activation metabolic rate of glucose is increased in the respective brain areas in relation to the strength and complexity of the stimulation. In patients suffering from ischaemic stroke glucose metabolism is markedly decreased within the infarction. Additonally, glucose metabolism is reduced by 20% in morphologically intact areas of the homolateral cortex, in the basal ganglia, in the cortical area contralateral to the infarction and in the contralateral cerebellum. This remote reduction of glucose utilization is probably caused by functional inactivation of these brain structures; it could be responsible for the diffuse organic syndrome in stroke victims not caused by the focal lesion. In patients suffering from dementia of the multi-infarct type and of the Alzheimer type glucose metabolism is reduced; the lesions in Alzheimer cases are most prominent in partietal and frontal cortical areas. In Chorea Huntington cases glucose metabolism is primarily disturbed in the striate, especially in the caudate nucleus; in these cases the metabolic disturbance can be detected earlier than the atrophy in computed tomograms. Disturbances of glucose and oxygen utilization are not necessary causes, but may also be sequelae od functional impairment. Additional information on pathogentic mechanisms may be obtained by the investigation of the protein synthesis.

  19. Diagnosis of temporal lobe epilepsy by positron emission tomography

    International Nuclear Information System (INIS)

    Shimizu, Hiroyuki; Ishijima, Buichi; Iio, Masaaki.

    1985-01-01

    Positron emission tomography(PET) was performed in 18 temporal lobe epileptics. About 20 mCi of 11 C-glucose was perorally administered to the patients and 30 minutes later scanning was started when the transport of 11 C-glucose from blood to the brain tissue reached equilibrium. At the level of 25mm above orbitomeatal line, the slice image of the temporal lobe shows a relatively high metabolic oval ring involving the amygdala, hippocapal formation and the hippocampal gyrus medially and the T 1 , T 2 and T 3 neocortices laterally in normal subjects. The epileptic focus, when detected on PET images, was observed as a defect in this oval ring. In 15(83.3%) out of 18 cases, the location of epileptic focus was confirmed as a low metabolic defect. This diagnosis rate was higher than that of other focal epilepsy by PET study. The locations of foci were devided into three types: mesial (5 cases), lateral (4 cases) and combined (6 cases). The seizure symptoms of the patients were analyzed in terms of the correspondence to the focus types. The results showed that automatism and pseudoabsence had a close relation to the mesial and combined types and psychical, vertiginous or visual seizures correlated to the combined and lateral types. Visceral or motor seizures were induced equally by any focus types. These facts suggested that automatism and pseudoabsence were correlated with the mesial organs such as the amygdala and hippocampus and psychical, vertiginous or visual seizures had origin in lateral neocortices. Visceral or motor seizures were supposed to be the results of the spread from the temporal focus to the adjacent structures. It was concluded that PET was very useful in localization diagnosis of temporal lobe epilepsy. In surgical treatment of epilepsy, in which the knowledge of the exact extent of epileptic foci is strongly demanded, PET study will offer invaluable data to the strategy of operation and foreseeing its prognosis. (author)

  20. Application of positron emission tomography in industrial research

    International Nuclear Information System (INIS)

    Jonkers, G.; van den Bergen, E.A.; Vonkeman, K.A.

    1990-01-01

    Positron Emission computed Tomography (PET) is a relatively new imaging technique, exploiting the 511 keV annihilation radiation characteristic of positron emitters. Although exclusively used till now in the field of nuclear medicine, the application of PET for the non-invasive, in-situ visualisation of processes of industrial interest is challenging, because PET can in principle be used to obtain quantitative, 2D/3D images of the flow and distribution of fluids inside process units, whose steel walls may be up to several centimeters thick. With the aid of a NeuroECAT positron tomographer the PET technique has been utilised to image important (model) processes in the petrochemical industry, using physical labelling of the phase to be imaged. First, the displacement of a brine/surfactant phase, labelled with 66 Ga-EDTA, in a piece of reservoir rock was imaged. Secondly, the dehydration of water-in-oil emulsions was monitored dynamically by labelling the water phase with 68 Ga-EDTA. The second study in particular demonstrates that in the presence of noisy data the image reconstruction method utilised strongly influences the results obtained. With the advent of PET in nuclear medicine the availability of short-lived positron emitting nuclides like 11 C (t1/2 = 20 min), 13 N (t1/2 = 10 min) and 15 0 (t1/2 = 2 min) has increased considerably, allowing the investigation of industrially important reactions by chemical labelling. Utilising the NeuroECAT in a special mode, the catalytic oxidation of carbon monoxide could be imaged in a model tubular reactor by using 11 C-labelled CO, providing information about the kinetics of the individual reaction steps and interactions and about the degree of occupation of catalytically active sites. (author)

  1. Positron emission tomography in urological cancer; Positronenemissionstomographie bei urologischen Tumoren

    Energy Technology Data Exchange (ETDEWEB)

    Wit, M. de [Universitaetskrankenhaus Eppendorf, Hamburg (Germany). Abt. Onkologie/Haematologie, Medizinische Klinik; Kotzerke, J. [Universitaetsklinikum Ulm (DE). Radiologie III (Nuklearmedizin)

    2000-09-01

    In staging cancer of the urinary bladder, the kidneys and the prostate and of testicular cancer there is a need for detecting tumor involvement of the lymph nodes to avoid surgical exploration. Positron emission tomography (PET) using fluorodeoxyglucose (FDG) can detect tumorous lymph nodes (sensitivity: 70%, specificity: 85%) which is helpful for several patients. In carcinoma of the prostate, other radiotracers than FDG (e.g. C-11-choline) might be more sensitive to detect tumorous lymph nodes. Up to now no diagnostical benefit of PET in germ cell tumors could be demonstrated in the published small series. In principle FDG-PET is useful in diagnosis of recurrence. In germ cell cancer FDG-PET seems to identify effectively persistent vital tumor tissue after chemotherapy. A multicenter study was initiated to demonstrate the potential of FDG-PET in a sufficient number of patients with germ cell tumor. (orig.) [German] Bei Harnblasen-, Nieren-, Prostata- und Hodenkarzinomen besteht aus klinischer Sicht ein Bedarf an verbessertem Lymphknoten-Staging, um die operative Evaluation zu vermeiden. Die Positronenemissionstomographie (PET) mit Fluordeoxyglukose (FDG) kann daher im Einzelfall bei Harnblasen- und Nierenkarzinomen hilfreich sein (bei Sensitivitaet um 70% und Spezifitaet um 85%). Beim Prostatakarzinom koennten sich andere Radiotracer (z.B. C-11-Cholin) bei der Detektion von tumoroesen Lymphknoten ueberlegen erweisen. Bei Keimzelltumoren konnte ein Nutzen der PET im primaeren Staging bei den bisher publizierten kleinen Studien nicht nachgewiesen werden. Fuer die Rezidivdiagnostik ist bei den genannten Tumoren aus grundsaetzlicher Ueberlegung der Einsatz von DFG-PET sinnvoll. Die Erkennung von vitalem malignen Tumorgewebe nach Chemotherapie erscheint bei Keimzelltumoren mit FDG-PET weitgehend sicher zu gelingen. Eine multizentrische Studie wurde begonnen, die hierueber Aufschluss geben wird. (orig.)

  2. Alcohol ADME in primates studied with positron emission tomography.

    Directory of Open Access Journals (Sweden)

    Zizhong Li

    Full Text Available The sensitivity to the intoxicating effects of alcohol as well as its adverse medical consequences differ markedly among individuals, which reflects in part differences in alcohol's absorption, distribution, metabolism, and elimination (ADME properties. The ADME of alcohol in the body and its relationship with alcohol's brain bioavailability, however, is not well understood.The ADME of C-11 labeled alcohol, CH(3 (11CH(2OH, 1 and C-11 and deuterium dual labeled alcohol, CH(3 (11CD(2OH, 2 in baboons was compared based on the principle that C-D bond is stronger than C-H bond, thus the reaction is slower if C-D bond breaking occurs in a rate-determining metabolic step. The following ADME parameters in peripheral organs and brain were derived from time activity curve (TAC of positron emission tomography (PET scans: peak uptake (C(max; peak uptake time (T(max, half-life of peak uptake (T(1/2, the area under the curve (AUC(60 min, and the residue uptake (C(60 min.For 1 the highest uptake occurred in the kidney whereas for 2 it occurred in the liver. A deuterium isotope effect was observed in the kidneys in both animals studied and in the liver of one animal but not the other. The highest uptake for 1 and 2 in the brain was in striatum and cerebellum but 2 had higher uptake than 1 in all brain regions most evidently in thalamus and cingulate. Alcohol's brain uptake was significantly higher when given intravenously than when given orally and also when the animal was pretreated with a pharmacological dose of alcohol.The study shows that alcohol metabolism in peripheral organs had a large effect on alcohol's brain bioavailability. This study sets the stage for clinical investigation on how genetics, gender and alcohol abuse affect alcohol's ADME and its relationship to intoxication and medical consequences.

  3. GRB 090727 AND GAMMA-RAY BURSTS WITH EARLY-TIME OPTICAL EMISSION

    International Nuclear Information System (INIS)

    Kopač, D.; Gomboc, A.; Japelj, J.; Kobayashi, S.; Mundell, C. G.; Bersier, D.; Cano, Z.; Smith, R. J.; Steele, I. A.; Virgili, F. J.; Guidorzi, C.; Melandri, A.

    2013-01-01

    We present a multi-wavelength analysis of Swift gamma-ray burst GRB 090727, for which optical emission was detected during the prompt gamma-ray emission by the 2 m autonomous robotic Liverpool Telescope and subsequently monitored for a further two days with the Liverpool and Faulkes Telescopes. Within the context of the standard fireball model, we rule out a reverse shock origin for the early-time optical emission in GRB 090727 and instead conclude that the early-time optical flash likely corresponds to emission from an internal dissipation process. Putting GRB 090727 into a broader observational and theoretical context, we build a sample of 36 gamma-ray bursts (GRBs) with contemporaneous early-time optical and gamma-ray detections. From these GRBs, we extract a sub-sample of 18 GRBs, which show optical peaks during prompt gamma-ray emission, and perform detailed temporal and spectral analysis in gamma-ray, X-ray, and optical bands. We find that in most cases early-time optical emission shows sharp and steep behavior, and notice a rich diversity of spectral properties. Using a simple internal shock dissipation model, we show that the emission during prompt GRB phase can occur at very different frequencies via synchrotron radiation. Based on the results obtained from observations and simulation, we conclude that the standard external shock interpretation for early-time optical emission is disfavored in most cases due to sharp peaks (Δt/t < 1) and steep rise/decay indices, and that internal dissipation can explain the properties of GRBs with optical peaks during gamma-ray emission

  4. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer.

    Science.gov (United States)

    Yang, Zhongyi; Pan, Lingling; Cheng, Jingyi; Hu, Silong; Xu, Junyan; Ye, Dingwei; Zhang, Yingjian

    2012-07-01

    To investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity = 95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. © 2012 The Japanese Urological Association.

  5. Clinical value of whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography in the detection of metastatic bladder cancer

    International Nuclear Information System (INIS)

    Yang Zhongyi; Pan Lingling; Cheng Jingyi; Hu Silong; Xu Junyan; Zhang Yingjian; Ye Dingwei

    2012-01-01

    The objective of this study was to investigate the value of whole-body fluorine-18 2-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography for the detection of metastatic bladder cancer. From December 2006 to August 2010, 60 bladder cancer patients (median age 60.5 years old, range 32-96) underwent whole body positron emission tomography/computed tomography positron emission tomography/computed tomography. The diagnostic accuracy was assessed by performing both organ-based and patient-based analyses. Identified lesions were further studied by biopsy or clinically followed for at least 6 months. One hundred and thirty-four suspicious lesions were identified. Among them, 4 primary cancers (2 pancreatic cancers, 1 colonic and 1 nasopharyngeal cancer) were incidentally detected, and the patients could be treated on time. For the remaining 130 lesions, positron emission tomography/computed tomography detected 118 true positive lesions (sensitivity=95.9%). On the patient-based analysis, the overall sensitivity and specificity resulted to be 87.1% and 89.7%, respectively. There was no difference of sensitivity and specificity in patients with or without adjuvant treatment in terms of detection of metastatic sites by positron emission tomography/computed tomography. Compared with conventional imaging modality, positron emission tomography/computed tomography correctly changed the management in 15 patients (25.0%). Positron emission tomography/computed tomography has excellent sensitivity and specificity in the detection of metastatic bladder cancer and it provides additional diagnostic information compared to standard imaging techniques. (author)

  6. High-resolution PET [Positron Emission Tomography] for Medical Science Studies

    Science.gov (United States)

    Budinger, T. F.; Derenzo, S. E.; Huesman, R. H.; Jagust, W. J.; Valk, P. E.

    1989-09-01

    One of the unexpected fruits of basic physics research and the computer revolution is the noninvasive imaging power available to today's physician. Technologies that were strictly the province of research scientists only a decade or two ago now serve as the foundations for such standard diagnostic tools as x-ray computer tomography (CT), magnetic resonance imaging (MRI), magnetic resonance spectroscopy (MRS), ultrasound, single photon emission computed tomography (SPECT), and positron emission tomography (PET). Furthermore, prompted by the needs of both the practicing physician and the clinical researcher, efforts to improve these technologies continue. This booklet endeavors to describe the advantages of achieving high resolution in PET imaging.

  7. Comparison of electrical capacitance tomography and gamma densitometer measurement in viscous oil-gas flows

    Energy Technology Data Exchange (ETDEWEB)

    Archibong Eso, A.; Zhao, Yabin; Yeung, Hoi [Department of Offshore Process and Energy Systems Engineering, Cranfield University, Cranfield (United Kingdom)

    2014-04-11

    Multiphase flow is a common occurrence in industries such as nuclear, process, oil and gas, food and chemical. A prior knowledge of its features and characteristics is essential in the design, control and management of such processes due to its complex nature. Electrical Capacitance Tomography (ECT) and Gamma Densitometer (Gamma) are two promising approaches for multiphase visualization and characterization in process industries. In two phase oil and gas flow, ECT and Gamma are used in multiphase flow monitoring techniques due to their inherent simplicity, robustness, and an ability to withstand wide range of operational temperatures and pressures. High viscous oil (viscosity > 100 cP) is of interest because of its huge reserves, technological advances in its production and unlike conventional oil (oil viscosity < 100 cP) and gas flows where ECT and Gamma have been previously used, high viscous oil and gas flows comes with certain associated concerns which include; increased entrainment of gas bubbles dispersed in oil, shorter and more frequent slugs as well as oil film coatings on the walls of flowing conduits. This study aims to determine the suitability of both devices in the visualization and characterization of high-viscous oil and gas flow. Static tests are performed with both devices and liquid holdup measurements are obtained. Dynamic experiments were also conducted in a 1 and 3 inch facility at Cranfield University with a range of nominal viscosities (1000, 3000 and 7500 cP). Plug, slug and wavy annular flow patterns were identified by means of Probability Mass Function and time series analysis of the data acquired from Gamma and ECT devices with high speed camera used to validate the results. Measured Liquid holdups for both devices were also compared.

  8. Exploring gamma radiation effect on exoelectron emission properties of bone

    Energy Technology Data Exchange (ETDEWEB)

    Zakaria, M.; Dekhtyar, Y.; Bogucharska, T.; Noskov, V. [Riga Technical Univ., Biomedical Engineering and Nanotechnology Institute (Latvia)

    2006-07-01

    Gamma radiation is used for radiation therapy to treat carcinogenic diseases including bone cancer. Ionising radiation kills carcinogenic calls. However, there are side effects of the gamma radiation on the bone surface electron structure. One of the effects is in the form of altering electron density of states of bone that, with time, influences biomedical reactions on bone life condition. (authors)

  9. Exploring gamma radiation effect on exoelectron emission properties of bone

    International Nuclear Information System (INIS)

    Zakaria, M.; Dekhtyar, Y.; Bogucharska, T.; Noskov, V.

    2006-01-01

    Gamma radiation is used for radiation therapy to treat carcinogenic diseases including bone cancer. Ionising radiation kills carcinogenic calls. However, there are side effects of the gamma radiation on the bone surface electron structure. One of the effects is in the form of altering electron density of states of bone that, with time, influences biomedical reactions on bone life condition. (authors)

  10. THERMAL X-RAY EMISSION FROM THE SHOCKED STELLAR WIND OF PULSAR GAMMA-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Zabalza, V.; Paredes, J. M. [Departament d' Astronomia i Meteorologia, Institut de Ciencies del Cosmos (ICC), Universitat de Barcelona (IEEC-UB), Marti i Franques 1, E08028 Barcelona (Spain); Bosch-Ramon, V., E-mail: vzabalza@am.ub.es [Dublin Institute for Advanced Studies, 31 Fitzwilliam Place, Dublin 2 (Ireland)

    2011-12-10

    Gamma-ray-loud X-ray binaries are binary systems that show non-thermal broadband emission from radio to gamma rays. If the system comprises a massive star and a young non-accreting pulsar, their winds will collide producing broadband non-thermal emission, most likely originated in the shocked pulsar wind. Thermal X-ray emission is expected from the shocked stellar wind, but until now it has neither been detected nor studied in the context of gamma-ray binaries. We present a semi-analytic model of the thermal X-ray emission from the shocked stellar wind in pulsar gamma-ray binaries, and find that the thermal X-ray emission increases monotonically with the pulsar spin-down luminosity, reaching luminosities of the order of 10{sup 33} erg s{sup -1}. The lack of thermal features in the X-ray spectrum of gamma-ray binaries can then be used to constrain the properties of the pulsar and stellar winds. By fitting the observed X-ray spectra of gamma-ray binaries with a source model composed of an absorbed non-thermal power law and the computed thermal X-ray emission, we are able to derive upper limits on the spin-down luminosity of the putative pulsar. We applied this method to LS 5039, the only gamma-ray binary with a radial, powerful wind, and obtain an upper limit on the pulsar spin-down luminosity of {approx}6 Multiplication-Sign 10{sup 36} erg s{sup -1}. Given the energetic constraints from its high-energy gamma-ray emission, a non-thermal to spin-down luminosity ratio very close to unity may be required.

  11. Contrast-enhanced fluorodeoxyglucose positron emission tomography/contrast-enhanced computed tomography in mediastinal T-cell lymphoma with superior vena cava syndrome

    International Nuclear Information System (INIS)

    Santhosh, Sampath; Gorla, Arun Kumar Reddy; Bhattacharya, Anish; Varma, Subhash Chander; Mittal, Bhagwant Rai

    2016-01-01

    Positron emission tomography-computed tomography (PET/CT) is a routine investigation for the staging of lymphomas. Contrast-enhanced computed tomography is mandatory whenever parenchymal lesions, especially in the liver and spleen are suspected. We report a rare case of primary mediastinal T-cell lymphoma evaluated with contrast-enhanced PET/CT that showed features of superior vena cava syndrome

  12. INTEGRAL Upper Limits on Gamma-Ray Emission Associated with the Gravitational Wave Event GW150914

    DEFF Research Database (Denmark)

    Savchenko, V.; Ferrigno, C.; Mereghetti, S.

    2016-01-01

    Using observations of the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL), we place upper limits on the gamma-ray and hard X-ray prompt emission associated with the gravitational wave event GW150914, which was discovered by the LIGO/Virgo Collaboration. The omnidirectional view...... in the 75 keV-2 MeV energy range for typical spectral models. Our results constrain the ratio of the energy promptly released in gamma-rays in the direction of the observer to the gravitational wave energy Eγ/EGW ... of the gravitational wave source, based on the available predictions for prompt electromagnetic emission....

  13. Multi-wavelength emission from 3C 66A: clues to its redshift and gamma-ray emission location

    International Nuclear Information System (INIS)

    Yan Da-Hai; Fan Zhong-Hui; Zhou Yao; Dai Ben-Zhong

    2013-01-01

    The quasi-simultaneous multi-wavelength emission of TeV blazar 3C 66A is studied by using a one-zone multi-component leptonic jet model. It is found that the quasi-simultaneous spectral energy distribution of 3C 66A can be well reproduced; in particular, the first three months of its average Fermi-LAT spectrum can be well reproduced by the synchrotron self-Compton component plus external Compton component of the broad line region (BLR). Clues to its redshift and gamma-ray emission location are obtained. The results indicate the following. (i) On the redshift: The theoretical intrinsic TeV spectra can be predicted by extrapolating the reproduced GeV spectra. Through comparing these extrapolated TeV spectra with the corrected observed TeV spectra from extragalactic background light, it is suggested that the redshift of 3C 66A could be between 0.1 and 0.3, with the most likely value being ∼ 0.2. (ii) On the gamma-ray emission location: To well reproduce the GeV emission of 3C 66A under different assumptions on the BLR, the gamma-ray emission region is always required to be beyond the inner zone of the BLR. The BLR absorption effect on gamma-ray emission confirms this point.

  14. Pinhole single-photon emission tomography reconstruction based on median root prior

    International Nuclear Information System (INIS)

    Sohlberg, Antti; Kuikka, Jyrki T.; Ruotsalainen, Ulla

    2003-01-01

    The maximum likelihood expectation maximisation (ML-EM) algorithm can be used to reduce reconstruction artefacts produced by filtered backprojection (FBP) methods in pinhole single-photon emission tomography (SPET). However, ML-EM suffers from noise propagation along iterations, which leads to quantitatively unpleasant reconstruction results. To avoid this increase in noise, the median root prior (MRP) algorithm for pinhole SPET was implemented. Projection data of a line source and Picker's thyroid phantom were collected using a single-head gamma camera with a pinhole collimator. MRP was added to existing pinhole ML-EM reconstruction algorithm and the phantom studies were reconstructed using MRP, ML-EM and FBP for comparison. Coefficients of variation, contrasts and full-widths at half-maximum were calculated and showed a clear reduction in noise without significant loss of resolution or decrease in contrast when MRP was applied. MRP also produced visually pleasing images even with high iteration numbers, free of the checkerboard-type noise patterns which are typical of ML-EM images. (orig.)

  15. Positron Emission Tomography (PET) and its application in clinical diagnosis and functional brain organization studies

    International Nuclear Information System (INIS)

    Grabowska, A.; Krolicki, L.

    1997-01-01

    Recent advances in positron emission tomography (PET) and other brain-imaging techniques have made it possible to visualize the working brain while the human subject is thinking, speaking or planning an action. PET provides researches with an opportunity to infer the neuroanatomy of a given function. Subjects either inhale or are injected with a radioactive material that binds to a physiologically active compound in the body. This serves as a tracer of blood flow and metabolic processes that reflect the activation of a given structure by emitting gamma rays which may be detected through a tomograph. PET research has produced findings that extend our knowledge on several important issues such as cerebral representation of language, perception, attention or memory. It has also proven to be an important source of information for clinical diagnosis of various neurological and psychiatric diseases. The present article provides a short review of main achievements in those fields. However, functional brain imaging is not exempt from methodological and theoretical difficulties. The main limitations of the method have been outlined. (author)

  16. A Delphi study to establish national cost-effectiveness research priorities for positron emission tomography

    International Nuclear Information System (INIS)

    Robert, Glenn; Milne, Ruairidh

    1999-01-01

    Objective: This study aimed to determine the key cost-effectiveness research questions relating to positron emission tomography (PET) in the UK. Methods: A systematic literature review was conducted to establish the existing knowledge base relating to the cost-effectiveness of PET in the various conditions for which it has been proposed. A three-round postal Delphi study of relevant individuals was used to determine the key cost-effectiveness research questions relating to PET in the UK. The content and structure of the Delphi study was informed by the results of the literature review. Results: The most important cost-effectiveness research priorities for the National Health Service (NHS) relating to PET were in the clinical areas of lung cancer, breast cancer and the assessment of myocardial viability. Gamma camera PET using coincidence imaging was highlighted as a modality whose clinical role needed to be determined urgently. Conclusion: Underlying the cost-effectiveness research priorities which were established is the need for evidence that the use of the various PET modalities as a diagnostic technique will alter patient management as compared to existing diagnostic strategies. The findings of the project provide a contemporary overview of the potential role for PET in the NHS and will be relevant to other countries

  17. Cardiac single-photon emission-computed tomography using combined cone-beam/fan-beam collimation

    International Nuclear Information System (INIS)

    Gullberg, Grant T.; Zeng, Gengsheng L.

    2004-01-01

    The objective of this work is to increase system sensitivity in cardiac single-photon emission-computed tomography (SPECT) studies without increasing patient imaging time. For imaging the heart, convergent collimation offers the potential of increased sensitivity over that of parallel-hole collimation. However, if a cone-beam collimated gamma camera is rotated in a planar orbit, the projection data obtained are not complete. Two cone-beam collimators and one fan-beam collimator are used with a three-detector SPECT system. The combined cone-beam/fan-beam collimation provides a complete set of data for image reconstruction. The imaging geometry is evaluated using data acquired from phantom and patient studies. For the Jaszazck cardiac torso phantom experiment, the combined cone-beam/fan-beam collimation provided 1.7 times greater sensitivity than standard parallel-hole collimation (low-energy high-resolution collimators). Also, phantom and patient comparison studies showed improved image quality. The combined cone-beam/fan-beam imaging geometry with appropriate weighting of the two data sets provides improved system sensitivity while measuring sufficient data for artifact free cardiac images

  18. Single photon emission computed tomography and albumin colloid imaging of the liver

    International Nuclear Information System (INIS)

    Croft, B.Y.; Teates, C.D.; Honeyman, J.C.

    1984-01-01

    A single photon emission computed tomography (ECT) system using the GE 400T Anger camera with 37 PM tubes and the SPETS software has been installed in our clinical laboratory. It has been used in the study of liver imaging with Tc-99m albumin colloid and other agents. The object of the study is to define what improvement in liver diagnosis might be made using ECT. Patients were injected with 3-4 mCi (ca 120 MBq) of colloid; five standard liver-spleen views and a 64-image ECT study were acquired. The ECT images were acquired either in a circle of the radius of the longer transverse axis of the patient or in an ellipse to match the patient contour. Studies were corrected for the attenuation of the Tc-99m gamma rays by tissue. A series of normal and abnormal patients have been studied and the data analyzed. The significant change in the technique of ECT imaging is the elliptical motion of the camera head which allows a better approximation of the patient contour and improves the spatial resolution of the images. (orig.)

  19. Quantification of leg muscle perfusion using thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Oshima, M.; Akanabe, H.; Sakuma, S.; Yano, T.; Nishikimi, N.; Shionoya, S.

    1989-01-01

    The purpose of this study is to quantify leg muscle perfusion with 201 Tl single photon emission computed tomography (SPECT). Six normal controls and 21 patients with peripheral arterial disease underwent this examination. Thallium-201 leg SPECT of both stress and redistribution was performed using a dual-headed digital gamma camera. Each slice of transverse images was normalized with pixels and whole-body counts. In normal controls, the activity of posterior tibial muscle components was significantly higher than that of anterior tibial muscle components (p less than 0.001). In 14 components, where patients had insignificant lesions, profile curves were normal in 10 (71%). In 62 components, where patients had arteriographically significant lesions, stress profile curves were abnormal in 57 (92%) compared with normal controls. Approximately, in half (28/62) components which had significant lesions, profile curves showed redistribution after 3 hr compared with normal redistribution curves. In three patients who underwent successful bypass graftings, the activity of each muscle component returned to a normal range

  20. Detection of non-aggressive stage IA lung cancer using chest computed tomography and positron emission tomography/computed tomography.

    Science.gov (United States)

    Shiono, Satoshi; Yanagawa, Naoki; Abiko, Masami; Sato, Toru

    2014-10-01

    In contrast to lung cancer with ground-glass opacity, the radiological investigation of solid lung cancer has not been well examined. The aim of this study was to explore chest computed tomography (CT) and positron emission tomography (PET)/CT findings with regard to outcomes after lung cancer surgery in order to radiologically classify clinical stage IA lung cancers by tumour aggressiveness. Three hundred and fifteen clinical stage IA patients were analysed. Four groups were defined by tumour solidity on CT and by the standardized uptake value (SUV) index on PET-CT (tumour maximum SUV/mean right liver lobe SUV). We analysed the association between radiological findings and both pathological invasiveness and postoperative outcome. Group A (n = 84) had an SUV index <1.0 and non-solid tumours, Group B (n = 24) had an SUV index <1.0 and solid tumours, Group C (n = 54) had an SUV index ≥1.0 and non-solid tumours, while Group D (n = 153) had an SUV index ≥1.0 and solid tumours. Invasive lung cancer was found in 2/84 (2.4%) patients in Group A, 1/24 (4.2%) in Group B, 13/54 (24.1%) in Group C and 58/153 (37.9%) in Group D (P < 0.01). The 5-year recurrence-free rate was 100% in Groups A and B, 90.3% in C and 65.7% in D (P < 0.01). The cancer-specific survival rate was 100% in A and B, 94.6% in C and 81.7% in D (P < 0.01). The present results suggest that preoperative PET/CT and thin-section CT findings provide important information for a selection of surgical procedures for clinical stage IA lung cancers. In clinical stage IA lung cancers displaying solid or non-solid density in thin-section findings, an SUV index <1.0 may be a better criterion for detecting non-aggressive lung cancer even in solid lung cancers. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Positron Emission Tomography Computed Tomography: A Guide for the General Radiologist.

    Science.gov (United States)

    Beadsmoore, Clare; Newman, David; MacIver, Duncan; Pawaroo, Davina

    2015-11-01

    Cancer remains a leading cause of death in Canada and worldwide. Whilst advances in anatomical imaging to detect and monitor malignant disease have continued over the last few decades, limitations remain. Functional imaging, such as positron emission tomography (PET), has improved the sensitivity and specificity in detecting malignant disease. In combination with computed tomography (CT), PET is now commonly used in the oncology setting and is an integral part of many cancer patients' pathways. Although initially the CT component of the study was purely for attenuation of the PET imaging and to provide anatomical coregistration, many centers now combine the PET study with a diagnostic quality contrast enhanced CT to provide one stop staging, thus refining the patient's pathway. The commonest tracer used in everyday practice is FDG (F18-fluorodeoxyglucose). There are many more tracers in routine clinical practice and those with emerging roles, such as 11C-choline, useful in the imaging of prostate cancer; 11C-methionine, useful in imaging brain tumours; C11-acetate, used in imaging hepatocellular carcinomas; 18F-FLT, which can be used as a marker of cellular proliferation in various malignancies; and F18-DOPA and various 68Ga-somatostatin analogues, used in patients with neuroendocrine tumours. In this article we concentrate on FDG PETCT as this is the most commonly available and widely utilised tracer now used to routinely stage a number of cancers. PETCT alters the stage in approximately one-third of patients compared to anatomical imaging alone. Increasingly, PETCT is being used to assess early metabolic response to treatment. Metabolic response can be seen much earlier than a change in the size/volume of the disease which is measured by standard CT imaging. This can aid treatment decisions in both in terms of modifying therapy and in addition to providing important prognostic information. Furthermore, it is helpful in patients with distorted anatomy from surgery

  2. Budget impact from the incorporation of positron emission tomography - computed tomography for staging lung cancers.

    Science.gov (United States)

    Biz, Aline Navega; Caetano, Rosângela

    2015-01-01

    To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer. The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease's prevalence and on the technologies' accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS) database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT) exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used. The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD) million for the restricted offer and 202.7 BRL (125.9 USD) million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD) million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD) and 600 BRL (372.8 USD) million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD) and 103.8 BRL (64.5 USD) million, considering PET-CT for negative CT and PET-CT for all, respectively. The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.

  3. Budget impact from the incorporation of positron emission tomography – computed tomography for staging lung cancers

    Directory of Open Access Journals (Sweden)

    Aline Navega Biz

    2015-01-01

    Full Text Available OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET in mediastinal and distant staging of non-small cell lung cancer.METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used.RESULTS The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD million for the restricted offer and 202.7 BRL (125.9 USD million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD and 600 BRL (372.8 USD million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD and 103.8 BRL (64.5 USD million, considering PET-CT for negative CT and PET-CT for all, respectively.CONCLUSIONS The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.

  4. Does positron emission tomography/computed tomography aid the diagnosis of prosthetic valve infective endocarditis?

    Science.gov (United States)

    Balmforth, Damian; Chacko, Jacob; Uppal, Rakesh

    2016-10-01

    A best evidence topic was constructed according to a structured protocol. The question addressed was whether (18)F-fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) aids the diagnosis of prosthetic valve endocarditis (PVE)? A total of 107 publications were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. The reported outcome of all studies was a final diagnosis of confirmed endocarditis on follow-up. All the six studies were non-randomized, single-centre, observational studies and thus represented level 3 evidence. The diagnostic capability of PET/CT for PVE was compared with that of the modified Duke Criteria and echocardiography, and reported in terms of sensitivity, specificity and positive and negative predictive values. All studies demonstrated an increased sensitivity for the diagnosis of PVE when PET/CT was combined with the modified Duke Criteria on admission. A higher SUVmax on PET was found to be significantly associated with a confirmed diagnosis of endocarditis and an additional diagnostic benefit of PET/CT angiography over conventional PET/non-enhanced CT is reported due to improved anatomical resolution. However, PET/CT was found to be unreliable in the early postoperative period due to its inability to distinguish between infection and residual postoperative inflammatory changes. PET/CT was also found to be poor at diagnosing cases of native valve endocarditis. We conclude that PET/CT aids in the diagnosis of PVE when combined with the modified Duke Criteria on admission by increasing the diagnostic sensitivity. The diagnostic ability of PET/CT can be potentiated by the use of PET/CTA; however, its use may be unreliable in the early postoperative period or in native valve endocarditis. © The Author 2016. Published by

  5. The contribution of single photon emission computed tomography in the clinical assessment of Alzheimer type dementia

    International Nuclear Information System (INIS)

    Boudousq, V.; Collombier, L.; Kotzki, P.O.

    1999-01-01

    Interest of brain single-photon emission computed tomography to support clinical diagnosis of Alzheimer-type dementia is now established. Numerous studies have reported a decreased perfusion in the association cortex of the parietal lobe and the posterior temporal regions. In patients with mild cognitive complaints, the presence of focal hypoperfusion may increase substantially the probability of the disease. In addition, emission tomography emerges as a helpful tool in situation in which there is diagnostic doubt. In this case, the presence of temporo-parietal perfusion deficit associated with hippocampal atrophy on MRI or X-ray computed tomography contributes to diagnostic accuracy. However, some studies suggest that emission tomography may be useful for preclinical prediction of Alzheimer's disease and to predict cognitive decline. (author)

  6. A general class of preconditioners for statistical iterative reconstruction of emission computed tomography

    International Nuclear Information System (INIS)

    Chinn, G.; Huang, S.C.

    1997-01-01

    A major drawback of statistical iterative image reconstruction for emission computed tomography is its high computational cost. The ill-posed nature of tomography leads to slow convergence for standard gradient-based iterative approaches such as the steepest descent or the conjugate gradient algorithm. In this paper new theory and methods for a class of preconditioners are developed for accelerating the convergence rate of iterative reconstruction. To demonstrate the potential of this class of preconditioners, a preconditioned conjugate gradient (PCG) iterative algorithm for weighted least squares reconstruction (WLS) was formulated for emission tomography. Using simulated positron emission tomography (PET) data of the Hoffman brain phantom, it was shown that the convergence rate of the PCG can reduce the number of iterations of the standard conjugate gradient algorithm by a factor of 2--8 times depending on the convergence criterion

  7. Nondestructive and quantitative characterization of TRU and LLW mixed-waste using active and passive gamma-ray spectrometry and computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Camp, D.C.; Martz, H.E.

    1991-11-12

    The technology being proposed by LLNL is an Active and Passive Computed Tomography (A P CT) Drum Scanner for contact-handled (CH) wastes. It combines the advantages offered by two well-developed nondestructive assay technologies: gamma-ray spectrometry and computed tomography (CT). Coupled together, these two technologies offer to nondestructively and quantitatively characterize mixed- wastes forms. Gamma-ray spectroscopy uses one or more external radiation detectors to passively and nondestructively measure the energy spectrum emitted from a closed container. From the resulting spectrum one can identify most radioactivities detected, be they transuranic isotopes, mixed-fission products, activation products or environmental radioactivities. Spectral libraries exist at LLNL for all four. Active (A) or transmission CT is a well-developed, nondestructive medical and industrial technique that uses an external-radiation beam to map regions of varying attenuation within a container. Passive (P) or emission CT is a technique mainly developed for medical application, e.g., single-photon emission CT. Nondestructive industrial uses of PCT are under development and just coming into use. This report discuses work on the A P CT Drum Scanner at LLNL.

  8. Nondestructive and quantitative characterization of TRU and LLW mixed-waste using active and passive gamma-ray spectrometry and computed tomography

    International Nuclear Information System (INIS)

    Camp, D.C.; Martz, H.E.

    1991-01-01

    The technology being proposed by LLNL is an Active and Passive Computed Tomography (A ampersand P CT) Drum Scanner for contact-handled (CH) wastes. It combines the advantages offered by two well-developed nondestructive assay technologies: gamma-ray spectrometry and computed tomography (CT). Coupled together, these two technologies offer to nondestructively and quantitatively characterize mixed- wastes forms. Gamma-ray spectroscopy uses one or more external radiation detectors to passively and nondestructively measure the energy spectrum emitted from a closed container. From the resulting spectrum one can identify most radioactivities detected, be they transuranic isotopes, mixed-fission products, activation products or environmental radioactivities. Spectral libraries exist at LLNL for all four. Active (A) or transmission CT is a well-developed, nondestructive medical and industrial technique that uses an external-radiation beam to map regions of varying attenuation within a container. Passive (P) or emission CT is a technique mainly developed for medical application, e.g., single-photon emission CT. Nondestructive industrial uses of PCT are under development and just coming into use. This report discuses work on the A ampersand P CT Drum Scanner at LLNL

  9. Recurrent proliferating trichilemmal tumor with malignant change on the f-18 fluorodeoxyglucose position emission tomography/computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Eun Ha; Kim, Eun Ha; Kim, Young Jun; Yoo, Seol Bong; Nam, Kyung Hwa [Presbyterian Medical Center, Seonam University College of Medicine, Jeonju (Korea, Republic of)

    2016-06-15

    F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography scan has been used for the diagnosis, assessment of treatment response, and follow-up of various neoplasms. Proliferating trichilemmal cyst or tumor (PTT) is a rare neoplasm, originated from the outer root sheath of a hair follicle. Because this tumor has unpredictable biological and clinical behavior, the long-term clinical follow-up is necessary to detect metastasis or recurrence. We reported a case of recurrent malignant PTT on scalp that showed increased FDG uptake.

  10. Spectrum of fluorodeoxyglucose-positron emission tomography/computed tomography and magnetic resonance imaging findings of ovarian tumors.

    Science.gov (United States)

    Kitajima, Kazuhiro; Ueno, Yoshiko; Maeda, Tetsuo; Murakami, Koji; Kaji, Yasushi; Kita, Masato; Suzuki, Kayo; Sugimura, Kazuro

    2011-11-01

    The purpose of this article is to review fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) and magnetic resonance imaging (MRI) findings in a variety of benign, malignant, and borderline malignant ovarian tumors. It is advantageous to become familiar with the wide variety of FDG-PET/CT findings of this entity. Benign ovarian tumors generally have faint uptake, whereas endometriomas, fibromas, and teratomas show mild to moderate uptake. Malignant ovarian tumors generally have intense uptake, whereas tumors with a small solid component often show minimal uptake.

  11. Positron emission tomography/computed tomography and biomarkers for early treatment response evaluation in metastatic colon cancer

    DEFF Research Database (Denmark)

    Engelmann, Bodil E.; Loft, Annika; Kjær, Andreas

    2014-01-01

    BACKGROUND: Treatment options for metastatic colon cancer (mCC) are widening. We prospectively evaluated serial 2-deoxy-2-[18F]fluoro-d-glucose positron-emission tomography/computed tomography (PET/CT) and measurements of tissue inhibitor of metalloproteinases-1 (TIMP-1), carcinoembryonic antigen...... evaluated by PET/CT before treatment, after one and four treatment series. Morphological and metabolic response was independently assessed according to Response Evaluation Criteria in Solid Tumors and European Organization for Research and Treatment of Cancer PET criteria. Plasma TIMP-1, plasma u...

  12. Contrast-enhanced 18F-fluorodeoxyglucose positron emission tomography/computed tomography in immunoglobulin G4-related retroperitoneal fibrosis

    International Nuclear Information System (INIS)

    Sharma, Punit; Chatterjee, Piyali

    2015-01-01

    Immunoglobulin G4 (IgG4)-related disease encompasses a wide variety of immune disorders previously thought be distinct. IgG4-related retroperitoneal fibrosis is one such entity. Metabolic imaging with 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) can be useful in the management of IgG4-related retroperitoneal fibrosis. We here discuss the case of 63-year-old male with IgG4-related retroperitoneal fibrosis and the role, 18 F-FDG PET/CT played in his management

  13. Function's evaluation, perfusion and metabolism by positron emission tomography associated with multislice tomography (PET/CT) in patient with previous diagnosis to myocardial necrosis

    International Nuclear Information System (INIS)

    Campisi, Roxana; Aramayo, Natalia; Osorio, Amilcar

    2010-01-01

    A 64-years-old male patient with previous diagnosis of myocardial necrosis as assessed by myocardial perfusion gated single photon emission computed tomography (gSPECT) with 3-vessel-disease, left ventricular dysfunction and symptomatic by epigastric pain. The patient was referred for myocardial viability assessment by positron emission tomography (PET) to define clinical management decision. (authors) [es

  14. Monte Carlo simulation for the design of industrial gamma-ray transmission tomography

    International Nuclear Information System (INIS)

    Kim, Jongbum; Jung, Sunghee; Moon, Jinho; Kwon, Taekyong; Cho, Gyuseong

    2011-01-01

    The Monte Carlo simulation and experiment were carried out for a large-scale industrial gamma ray tomographic scanning geometry. The geometry of the tomographic system has a moving source with 16 stationary detectors. This geometry is advantageous for the diagnosis of a large-scale industrial plant. The simulation data was carried out for the phantom with 32 views, 16 detectors, and a different energy bin. The simulation data was processed to be used for image reconstruction. Image reconstruction was performed by a Diagonally-Scaled Gradient-Ascent algorithm for simulation data. Experiments were conducted in a 78 cm diameter column filled with polypropylene grains. Sixteen 0.5-inch-thick and 1 inch long NaI(Tl) cylindrical detectors, and 20 mCi of 137 Cs radioactive source were used. The experimental results were compared to the simulation data. The experimental results were similar to Monte Carlo simulation results. This result showed that the Monte Carlo simulation is useful for predicting the result of the industrial gamma tomographic scan method And it can also give a solution for designing the industrial gamma tomography system and preparing the field experiment. (author)

  15. Convergence analysis of a relaxed EM algorithm with uses in emission tomography

    International Nuclear Information System (INIS)

    Iusem, A.N.

    1989-01-01

    This work describes the Position Emission tomography technique this technique consists of introducing in the organism a radioactive substance and determining its concentration in each part of the body by measuring its emission in a detectors ring. (A.C.A.S.)

  16. Hard burst emission from the soft gamma repeater SGR 1900+14

    NARCIS (Netherlands)

    Woods, P.M.; Kouveliotou, C.; van Paradijs, J.; Briggs, M.S.; Hurley, K.; Göğüş, E.; Preece, R.D.; Giblin, T.W.; Thompson, C.; Duncan, R.C.

    1999-01-01

    We present evidence for burst emission from SGR 1900+14 with a power-law high-energy spectrum extending beyond 500 keV. Unlike previous detections of high-energy photons during bursts from soft gamma repeaters (SGRs), these emissions are not associated with extraordinarily bright flares. Not only is

  17. Smooth Optical Self-similar Emission of Gamma-Ray Bursts

    Energy Technology Data Exchange (ETDEWEB)

    Lipunov, Vladimir; Simakov, Sergey; Gorbovskoy, Evgeny; Vlasenko, Daniil, E-mail: lipunov2007@gmail.com [Lomonosov Moscow State University, Sternberg Astronomical Institute, Universitetsky prospect, 13, 119992, Moscow (Russian Federation)

    2017-08-10

    We offer a new type of calibration for gamma-ray bursts (GRB), in which some class of GRB can be marked and share a common behavior. We name this behavior Smooth Optical Self-similar Emission (SOS-similar Emission) and identify this subclasses of GRBs with optical light curves described by a universal scaling function.

  18. Effective dose to staff members in a positron emission tomography/CT facility using zirconium-89

    Science.gov (United States)

    2013-01-01

    Objective: Positron emission tomography (PET) using zirconium-89 (89Zr) is complicated by its complex decay scheme. In this study, we quantified the effective dose from 89Zr and compared it with fluorine-18 fludeoxyglucose (18F-FDG). Methods: Effective dose distribution in a PET/CT facility in Riyadh was calculated by Monte Carlo simulations using MCNPX. The positron bremsstrahlung, the annihilation photons, the delayed gammas from 89Zr and those emissions from 18F-FDG were modelled in the simulations but low-energy characteristic X-rays were ignored. Results: On the basis of injected activity, the dose from 89Zr was higher than that of 18F-FDG. However, the dose per scan from 89Zr became less than that from 18F-FDG near the patient, owing to the difference in injected activities. In the corridor and control rooms, the 89Zr dose was much higher than 18F-FDG, owing to the difference in attenuation by the shielding materials. Conclusion: The presence of the high-energy photons from 89Zr-labelled immuno-PET radiopharmaceuticals causes a significantly higher effective dose than 18F-FDG to the staff outside the patient room. Conversely, despite the low administered activity of 89Zr, it gives rise to a comparable or even lower dose than 18F-FDG to the staff near the patient. This interesting result raises apparently contradictory implications in the radiation protection considerations of a PET/CT facility. Advances in knowledge: To the best of our knowledge, radiation exposure to staff and public in the PET/CT unit using 89Zr has not been investigated. The ultimate output of this study will lead to the optimal design of the facility for routine use of 89Zr. PMID:23934963

  19. Fabrication of polycrystalline scintillators for the positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Karim, Kamran Said

    2010-01-01

    Transparent ceramics are becoming more and more important for two new types of applications. On the one hand in cases where high mechanical and thermal demands in combination with optical properties are required, on the other hand where the optical properties of transparent materials like glass are not sufficient e.g. in positron-emission-tomography (PET) diagnostics. Most state of the art PET-scanners are using high-priced single crystals as scintillator material. The technological challenge is to replace single crystal by cost-efficient transparent ceramics. Producing transparent ceramics is ordered in synthesis of the powders and in manufacturing of these into transparent ceramics. The aim of this work was to synthesize single phase yttrium-alumina-and Luthetiumalumina-garnet (YAG, LuAG) powders partially doped with neodymium or praseodymium by four different synthesis routes (Pechini-synthesis, sol-gel-route, coprecipitation and solid state reactions). Additionally industrial LuAG and LuPO 4 powders were characterized and manufactured. The powders were processed as submicron- and nanopowders. The compaction of nanopowder greenbodies sintered at high temperatures leads to a ''cross-over'' between both manufacturing route. Newly produced single-phase powders were homogenized with additions of sintering additives like tetraethyl orthosilicate (TEOS) and binders like polyvinyl alcohol (PVA). Moulding the powders were carried out by uniaxial pressing, cold isostatic pressing and in individual cases also by slip casting. The achieved green densities were in a range of 25-42 %. Examination of calcination behaviour leads to a calcination temperature of 1000 C with 2 hours dwell time in air atmosphere. Only solid state reactions resulted into transparent YAG, YAG:Pr, LuAG, LuAG:Pr ceramics. Solid state reactions of nanopowders resulted in heterogeneously transparent samples. Ceramics made by powders of other synthetic routes gave nontransparent ceramics due to porosity

  20. Practical implementation of tetrahedral mesh reconstruction in emission tomography

    Science.gov (United States)

    Boutchko, R.; Sitek, A.; Gullberg, G. T.

    2013-05-01

    This paper presents a practical implementation of image reconstruction on tetrahedral meshes optimized for emission computed tomography with parallel beam geometry. Tetrahedral mesh built on a point cloud is a convenient image representation method, intrinsically three-dimensional and with a multi-level resolution property. Image intensities are defined at the mesh nodes and linearly interpolated inside each tetrahedron. For the given mesh geometry, the intensities can be computed directly from tomographic projections using iterative reconstruction algorithms with a system matrix calculated using an exact analytical formula. The mesh geometry is optimized for a specific patient using a two stage process. First, a noisy image is reconstructed on a finely-spaced uniform cloud. Then, the geometry of the representation is adaptively transformed through boundary-preserving node motion and elimination. Nodes are removed in constant intensity regions, merged along the boundaries, and moved in the direction of the mean local intensity gradient in order to provide higher node density in the boundary regions. Attenuation correction and detector geometric response are included in the system matrix. Once the mesh geometry is optimized, it is used to generate the final system matrix for ML-EM reconstruction of node intensities and for visualization of the reconstructed images. In dynamic PET or SPECT imaging, the system matrix generation procedure is performed using a quasi-static sinogram, generated by summing projection data from multiple time frames. This system matrix is then used to reconstruct the individual time frame projections. Performance of the new method is evaluated by reconstructing simulated projections of the NCAT phantom and the method is then applied to dynamic SPECT phantom and patient studies and to a dynamic microPET rat study. Tetrahedral mesh-based images are compared to the standard voxel-based reconstruction for both high and low signal-to-noise ratio