WorldWideScience

Sample records for frame pc-plc regime

  1. An advanced lab frame PC-PLC regime for a power supply control

    International Nuclear Information System (INIS)

    Abdel-Bary, M

    2010-01-01

    A lab frame automatic control system (LFACS) based on a programmable logic controller (PLC) is designed, developed and tested in the laboratory. The LFACS is designed to control and monitor one DC power supply with output current accuracy 0.001 amps, one automatic valve. Also the LFACS will monitor one full range vacuum measurement and one water leak detector. The control system is built based on the internationally standard programmable logic controller (PLC) from Siemens. Two software's have been used; firstly SIMATIC S 7 lite has been used to build the control program and safety interlocks, secondly winCC flexible (runs in a PC computer and communicates with the PLC by multi point interface PC adapter (MPI) has been used to build the user-machine interface . This lab frame control system will be generalized to a global control system to control the MGC-20 cyclotron. The lab tests showed a reliable and flexible control system.

  2. Data communication between Panasonic PLC and PC using SerialPort control in C#.NET environment

    Science.gov (United States)

    Gao, Ting; Gan, Xiaochuan; Ma, Liqun

    2015-02-01

    With the gradual promotion of Microsoft.NET platform, C# as an object-oriented programming language based on the platform has been widely used. Therefore, more attention is concentrated on how to achieve the communication between Panasonic PLC and PC efficiently and fast in C#.NET environment. In this paper, a method of using SerialPort control which could be used for achieving communication between PLC and PC is introduced. Meanwhile, the reason of abnormal thread when displayed the receiving data in form is analyzed and the programming method to solve the problem of thread safety is designed. Achieving the communication of Panasonic PLC and PC in C#.NET environment can give full play to the advantages of the .NET framework. It is practical, easy communication, high reliability and can combine with other measurement and calibration procedures effectively and conveniently. Configuration software is expensive and can only communicate with PLC separately, but these shortcomings can be solved in C#.NET environment. A well-designed user interface realized real-time monitoring of PLC parameters and achieved management and control integration. The experiment show that this method of data transfer is accurate and the program' running is stable.

  3. Implementation of RS-485 Communication between PLC and PC of Distributed Control System Based on VB

    Science.gov (United States)

    Lian Zhang, Chuan; Da Huang, Zhi; Qing Zhou, Gui; Chong, Kil To

    2015-05-01

    This paper focuses on achieving RS-485 communication between programmable logical controller (PLC) and PC based on visual basic 6.0 (VB6.0) on an experimental automatic production line. Mitsubishi FX2N PLCs and a PC are chosen as slave stations and main station, respectively. Monitoring software is developed using VB6.0 for data input/output, flow control and online parameters setting. As a result, all functions are fulfilled with robust performance. It is concluded from results that one PC can monitor several PLCs using RS-485 communication.

  4. Framing of regimes and transition strategies

    DEFF Research Database (Denmark)

    Jensen, Jens Stissing

    2012-01-01

    This article suggests that transition strategies are always formulated in the context of specific representations of the regime and the challenges it faces. It is argued that the framing of a regime affects the envisioning of transition strategies. An analysis of the current development agenda...... for the housing construction sector in Denmark reveals the relevance and impacts of different regime framings. It is proposed that the ability to cope with framing issues as situated and political processes is at the core of the governance of transitions....

  5. Usage of Wifi Technology for PLC Programming

    Directory of Open Access Journals (Sweden)

    Jaromír ŠKUTA

    2009-06-01

    Full Text Available This contribution describes usage of WIFI technology for programming and parameterization of application in PLC. INSYS WLAN unit from the Microelectronics INSYS Corporation is the base of application. Software access point with using USB WIFI component WL167 is running in industrial PC. Particular PC clients are connecting into network infrastructure PLC by the help of this access point and INSYS WLAN unit. This connection allows configuring and uploading program into this PLC.

  6. Modelling regime shifts in the southern Benguela: a frame-based ...

    African Journals Online (AJOL)

    Modelling regime shifts in the southern Benguela: a frame-based approach. MD Smith, A Jarre. Abstract. This study explores the usefulness of a frame-based modelling approach in the southern Benguela upwelling ecosystem, with four frames describing observed small pelagic fish dominance patterns. We modelled the ...

  7. A PC-PCL-based control system for the high-voltage pulsed-power operation of the Intense Diagnostic Neutral Beam (IDNB) Experiment

    International Nuclear Information System (INIS)

    Gribble, R.

    1993-06-01

    A stand-alone, semiautomated control system for the high-voltage pulsed-power energy sources on the Intense Diagnostic Neutral Beam Experiment at Los Alamos National Laboratory using personal computer (PC) and programmable logic controller (PLC) technology has been developed and implemented. The control system, consisting of a PC with the graphic operator interface, the network connecting the PC to the PLC, the PLC, the PLC I/O modules, fiber-optic interfaces and software, is described

  8. Implementation of PID autotuning procedure in PLC controller

    Directory of Open Access Journals (Sweden)

    Daniun Marcin

    2017-01-01

    Full Text Available In this paper, we present the automatic PID tuning procedure based on the Method of Moments and AMIGO tuning rules. The advantage of the Method of Moments is that the time constant and transport delay are estimated at the areas rather than on the individual points. This results in high resistance to the measurement noises. The sensitivity to measurement noises is a serious problem in other autotuning methods. The second advantage of this method is that it approximates plant during identification process to first order model with time delay. We combined the Method of Moments with the AMIGO tuning rules and implemented this combination as a stand-alone autotuning procedure in Siemens S7-1200 PLC controller. Next, we compared this method with two built-in PID autotuning procedures which were available in Siemens S7-1200 PLC controller. The procedure was tested for three types of plant models: with lag-dominated, balanced, and delay-dominated dynamics. We simulated the plants on a PC in Matlab R2013a. The connection between the PC and PLC was maintained through a National Instruments data acquisition board, NI PCI-6229. We conducted tests for step change in the set point, trajectory tracking, and load disturbances. To assess control quality, we used IAE index. We limited our research to PI algorithm. The results prove that proposed method was better than two built-in tuning methods provided by Siemens, oscillating between a few and even a dozen percent in most cases. The proposed method is universal and can be implemented in any PLC controller.

  9. The Design and Realization of Virtual Machine of Embedded Soft PLC Running System

    Directory of Open Access Journals (Sweden)

    Qingzhao Zeng

    2014-11-01

    Full Text Available Currently soft PLC has been the focus of study object for many countries. Soft PLC system consists of the developing system and running system. A Virtual Machine is an important part in running system even in the whole soft PLC system. It explains and performs intermediate code generated by the developing system and updates I/O status of PLC in order to complete its control function. This paper introduced the implementation scheme and execution process of the embedded soft PLC running system Virtual Machine, and mainly introduced its software implementation method, including the realization of the input sampling program, the realization of the instruction execution program and the realization of output refresh program. Besides, an operation code matching method was put forward in the instruction execution program design. Finally, the test takes PowerPC/P1010 (Freescale as the hardware platform and Vxworks as the operating system, the system test result shows that accuracy, the real-time performance and reliability of Virtual Machine.

  10. Solucions PLC obertes

    OpenAIRE

    López Llauradó, Oriol

    2006-01-01

    Treball que, després de revisar el concepte de PLC i d'exposar la necessitat de solucions obertes, defineix el concepte de PLC obert, basat en programari lliure i presenta alguns projectes interessants de PLC obert. Trabajo que, después de revisar el concepto de PLC y de exponer la necesidad de soluciones abiertas, define el concepto de PLC abierto, basado en el software libre y presenta algunos proyectos interesantes de PLC abierto. Study that, after looking at the concept of PLC and s...

  11. PLC Programming

    International Nuclear Information System (INIS)

    Lee, Seong Jae; Wi, Seong Dong; Yoo, Jong Seon; Kim, Se Chan

    2001-02-01

    This book tells of PLC programming for KGL-WIN with summary of PLC, performance and function of PLC like characteristic of KGL-WIN, connection method with PLC, basic performance of K200S/K300S/K1000S, diagram of input and output H/W, writing project, staring the program, editing of program, on-line function, debugging and instructions like control, timer and counter, data transmission, comparison, rotation and moving, system, data operating data conversion and application program.

  12. PLC Berbasis Mikrokontroler Atmega16 Sebagai Pengganti PLC Konvensional

    OpenAIRE

    Brama, Adi; Kurniawan, Syafi’i Agus; Djaohar, Mochammad

    2015-01-01

    Making the research aims to design and build a PLC (Programmable Logic Controller) that uses a microcontroller ATmega16 as the brain of the Micro PLC system. The process of manufacture, testing is done in simulation tools at Pustikom State University of Jakarta and completed the process in May-June 2015. PLC Microcontroller ATmega16-Based As Substitute Conventional PLC, and use the application on a laptop LDmicro to make instructions that form the ladder program to run the output in the form ...

  13. Compartment-Specific Biosensors Reveal a Complementary Subcellular Distribution of Bioactive Furin and PC7

    Directory of Open Access Journals (Sweden)

    Pierpaolo Ginefra

    2018-02-01

    Full Text Available Furin trafficking, and that of related proprotein convertases (PCs, may regulate which substrates are accessible for endoproteolysis, but tools to directly test this hypothesis have been lacking. Here, we develop targeted biosensors that indicate Furin activity in endosomes is 10-fold less inhibited by decanoyl-RVKR-chloromethylketone and enriched >3-fold in endosomes compared to the trans-Golgi network (TGN. Endogenous PC7, which resists this inhibitor, was active in distinct vesicles. Only overexpressed PC7 activity reached the cell surface, endosomes, and the TGN. A PLC motif in the cytosolic tail of PC7 was dispensable for endosomal activity, but it was specifically required for TGN recycling and to rescue proActivin-A cleavage in Furin-depleted B16F1 melanoma cells. In sharp contrast, PC7 complemented Furin in cleaving Notch1 independently of PLC-mediated TGN access. Our study provides a proof in principle that compartment-specific biosensors can be used to gain insight into the regulation of PC trafficking and to map the tropism of PC-specific inhibitors.

  14. Construction of a multi-vender fieldbus system for PC-based control using soft PLC

    Energy Technology Data Exchange (ETDEWEB)

    Park, J. H.; Park, Y. J.; Choi, J. M.; Park, J. S. [Hankyong National Univ., Ansung (Korea)

    2000-12-01

    The relationship between the IEC 61131-3 programming language and the fieldbus application that became necessary as an outcome of the recent automation technology was described.An educational text for the field users on the integration of the Input/Output (I/O) modules and on the IEC 61131-3 programming language was prepared. An attempt was made to include description of the various kind of the fieldbuses and promote understanding of the CAN and the AS-I bus using a practical approach. The profibus is most widely used in the world, and thus is an important and a standardized tool in the area of the process control. A method of integrating the profibus with the most commonly used I/O modules in the field was suggested. The most essential characteristics of the IEC 61131-3 programming language was also described. A method for the construction of the multi-vender I/O modules by the Soft PLC 4C of the softings was suggested. Various technical steps are necessary for the integration of the I/O modules by the soft PLC. An additional software is needed for the more intelligent devises possessing complex technical functions, such as the control valve, the AC driver among others. The 4C control by the softing which is an important industrial solution for the soft PLC was specifically designed for the profibus. So, an OPC server is needed to exchange between the other fieldbuses while the optimum performance is only achieved by using the profibus card by softing. This implies that the business aspect has played a major role for developing the profibus by softing and the domestic users need to pay careful attention to this point additional software tools, such as the PDM or the comuwinn II, are necessary in the process control area to operate a complex and instruments using the DP/PA segment coupler. 13 refs., 46 figs., 12 tabs. (Author)

  15. PLC based development of control, monitoring and interlock for 100 kW, 45.6 MHz ICRH system

    International Nuclear Information System (INIS)

    Jadav, Hiralal; Joshi, Rameshkumar; Mali, Aniruddh K.; Kadia; Bhavesh; Parmar; Maganbhai, Kiritkumar; Kulkarni, S.V.

    2015-01-01

    This paper presents details of PLC based system development for 100KW at the rate 45.6 MHz. Presently in ICRH RF DAC (Data acquisition and control) system existing based on real time VME and linux operating system. The ICRH system consists of 1.5 MW RF generator operating at 22- 40MHz which is used for second harmonic heating and pre-ionization experiments on SST-1 Tokamak at 1.5T and 3T magnetic field operation respectively. The task of PLC system in RF ICRH is to control, monitoring and interlocks HVDC power supply signal. Voltage and current signal of 2 kW, 20 kW, tetrode for 100 kW RF tube electrode like Filament, Control grid, Plate, Screen grid, signal monitor and voltage set raised by PLC analog IO module. Acknowledgement of the HVDC supply Filament, Control grid, Plate, Screen grid power supply is monitor and interlocks by PLC Digital IO module to interlocks stop the RF pulse and off HV power supply. The RF pulse(shot) to trigger signal generator (5mw) RF power output feed to LPA then chain of 2 KW, 20 KW, 100 KW at the rate 45.6 MHz. The programming logic controller (PLC) software is written in ladder language for AH500 Delta make using ISP Soft 2.04 and GUI is in the table form to control and monitor the parameters. Communication of PLC to PC by ethernet LAN network. (author)

  16. Reliability analysis of PLC safety equipment

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J.; Kim, J. Y. [Chungnam Nat. Univ., Daejeon (Korea, Republic of)

    2006-06-15

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system.

  17. Reliability analysis of PLC safety equipment

    International Nuclear Information System (INIS)

    Yu, J.; Kim, J. Y.

    2006-06-01

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system

  18. LCFM - LIVING COLOR FRAME MAKER: PC GRAPHICS GENERATION AND MANAGEMENT TOOL FOR REAL-TIME APPLICATIONS

    Science.gov (United States)

    Truong, L. V.

    1994-01-01

    Computer graphics are often applied for better understanding and interpretation of data under observation. These graphics become more complicated when animation is required during "run-time", as found in many typical modern artificial intelligence and expert systems. Living Color Frame Maker is a solution to many of these real-time graphics problems. Living Color Frame Maker (LCFM) is a graphics generation and management tool for IBM or IBM compatible personal computers. To eliminate graphics programming, the graphic designer can use LCFM to generate computer graphics frames. The graphical frames are then saved as text files, in a readable and disclosed format, which can be easily accessed and manipulated by user programs for a wide range of "real-time" visual information applications. For example, LCFM can be implemented in a frame-based expert system for visual aids in management of systems. For monitoring, diagnosis, and/or controlling purposes, circuit or systems diagrams can be brought to "life" by using designated video colors and intensities to symbolize the status of hardware components (via real-time feedback from sensors). Thus status of the system itself can be displayed. The Living Color Frame Maker is user friendly with graphical interfaces, and provides on-line help instructions. All options are executed using mouse commands and are displayed on a single menu for fast and easy operation. LCFM is written in C++ using the Borland C++ 2.0 compiler for IBM PC series computers and compatible computers running MS-DOS. The program requires a mouse and an EGA/VGA display. A minimum of 77K of RAM is also required for execution. The documentation is provided in electronic form on the distribution medium in WordPerfect format. A sample MS-DOS executable is provided on the distribution medium. The standard distribution medium for this program is one 5.25 inch 360K MS-DOS format diskette. The contents of the diskette are compressed using the PKWARE archiving tools

  19. PC Scene Generation

    Science.gov (United States)

    Buford, James A., Jr.; Cosby, David; Bunfield, Dennis H.; Mayhall, Anthony J.; Trimble, Darian E.

    2007-04-01

    AMRDEC has successfully tested hardware and software for Real-Time Scene Generation for IR and SAL Sensors on COTS PC based hardware and video cards. AMRDEC personnel worked with nVidia and Concurrent Computer Corporation to develop a Scene Generation system capable of frame rates of at least 120Hz while frame locked to an external source (such as a missile seeker) with no dropped frames. Latency measurements and image validation were performed using COTS and in-house developed hardware and software. Software for the Scene Generation system was developed using OpenSceneGraph.

  20. Video frame processor

    International Nuclear Information System (INIS)

    Joshi, V.M.; Agashe, Alok; Bairi, B.R.

    1993-01-01

    This report provides technical description regarding the Video Frame Processor (VFP) developed at Bhabha Atomic Research Centre. The instrument provides capture of video images available in CCIR format. Two memory planes each with a capacity of 512 x 512 x 8 bit data enable storage of two video image frames. The stored image can be processed on-line and on-line image subtraction can also be carried out for image comparisons. The VFP is a PC Add-on board and is I/O mapped within the host IBM PC/AT compatible computer. (author). 9 refs., 4 figs., 19 photographs

  1. Lysophosphatidic acid induces reactive oxygen species generation by activating protein kinase C in PC-3 human prostate cancer cells

    International Nuclear Information System (INIS)

    Lin, Chu-Cheng; Lin, Chuan-En; Lin, Yueh-Chien; Ju, Tsai-Kai; Huang, Yuan-Li; Lee, Ming-Shyue; Chen, Jiun-Hong; Lee, Hsinyu

    2013-01-01

    Highlights: •LPA induces ROS generation through LPA 1 and LPA 3 . •LPA induces ROS generation by activating PLC. •PKCζ mediates LPA-induced ROS generation. -- Abstract: Prostate cancer is one of the most frequently diagnosed cancers in males, and PC-3 is a cell model popularly used for investigating the behavior of late stage prostate cancer. Lysophosphatidic acid (LPA) is a lysophospholipid that mediates multiple behaviors in cancer cells, such as proliferation, migration and adhesion. We have previously demonstrated that LPA enhances vascular endothelial growth factor (VEGF)-C expression in PC-3 cells by activating the generation of reactive oxygen species (ROS), which is known to be an important mediator in cancer progression. Using flow cytometry, we showed that LPA triggers ROS generation within 10 min and that the generated ROS can be suppressed by pretreatment with the NADPH oxidase (Nox) inhibitor diphenylene iodonium. In addition, transfection with LPA 1 and LPA 3 siRNA efficiently blocked LPA-induced ROS production, suggesting that both receptors are involved in this pathway. Using specific inhibitors and siRNA, phospholipase C (PLC) and protein kinase C (PKC) were also suggested to participate in LPA-induced ROS generation. Overall, we demonstrated that LPA induces ROS generation in PC-3 prostate cancer cells and this is mediated through the PLC/PKC/Nox pathway

  2. Lysophosphatidic acid induces reactive oxygen species generation by activating protein kinase C in PC-3 human prostate cancer cells

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Chu-Cheng; Lin, Chuan-En; Lin, Yueh-Chien [Institute of Zoology, College of Life Science, National Taiwan University, Taipei, Taiwan, ROC (China); Ju, Tsai-Kai [Instrumentation Center, National Taiwan University, Taipei, Taiwan, ROC (China); Technology Commons, College of Life Science, National Taiwan University, Taipei, Taiwan, ROC (China); Huang, Yuan-Li [Department of Biotechnology, Asia University, Taichung, Taiwan, ROC (China); Lee, Ming-Shyue [Institute of Biochemistry and Molecular Biology, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC (China); Chen, Jiun-Hong [Institute of Zoology, College of Life Science, National Taiwan University, Taipei, Taiwan, ROC (China); Department of Life Science, College of Life Science, National Taiwan University, Taipei, Taiwan, ROC (China); Lee, Hsinyu, E-mail: hsinyu@ntu.edu.tw [Institute of Zoology, College of Life Science, National Taiwan University, Taipei, Taiwan, ROC (China); Department of Life Science, College of Life Science, National Taiwan University, Taipei, Taiwan, ROC (China); Center for Biotechnology, National Taiwan University, Taipei, Taiwan, ROC (China); Research Center for Developmental Biology and Regenerative Medicine, National Taiwan University, Taipei, Taiwan, ROC (China)

    2013-11-01

    Highlights: •LPA induces ROS generation through LPA{sub 1} and LPA{sub 3}. •LPA induces ROS generation by activating PLC. •PKCζ mediates LPA-induced ROS generation. -- Abstract: Prostate cancer is one of the most frequently diagnosed cancers in males, and PC-3 is a cell model popularly used for investigating the behavior of late stage prostate cancer. Lysophosphatidic acid (LPA) is a lysophospholipid that mediates multiple behaviors in cancer cells, such as proliferation, migration and adhesion. We have previously demonstrated that LPA enhances vascular endothelial growth factor (VEGF)-C expression in PC-3 cells by activating the generation of reactive oxygen species (ROS), which is known to be an important mediator in cancer progression. Using flow cytometry, we showed that LPA triggers ROS generation within 10 min and that the generated ROS can be suppressed by pretreatment with the NADPH oxidase (Nox) inhibitor diphenylene iodonium. In addition, transfection with LPA{sub 1} and LPA{sub 3} siRNA efficiently blocked LPA-induced ROS production, suggesting that both receptors are involved in this pathway. Using specific inhibitors and siRNA, phospholipase C (PLC) and protein kinase C (PKC) were also suggested to participate in LPA-induced ROS generation. Overall, we demonstrated that LPA induces ROS generation in PC-3 prostate cancer cells and this is mediated through the PLC/PKC/Nox pathway.

  3. Melatonin potentiates glycine currents through a PLC/PKC signalling pathway in rat retinal ganglion cells.

    Science.gov (United States)

    Zhao, Wen-Jie; Zhang, Min; Miao, Yanying; Yang, Xiong-Li; Wang, Zhongfeng

    2010-07-15

    In vertebrate retina, melatonin regulates various physiological functions. In this work we investigated the mechanisms underlying melatonin-induced potentiation of glycine currents in rat retinal ganglion cells (RGCs). Immunofluorescence double labelling showed that rat RGCs were solely immunoreactive to melatonin MT(2) receptors. Melatonin potentiated glycine currents of RGCs, which was reversed by the MT(2) receptor antagonist 4-P-PDOT. The melatonin effect was blocked by intracellular dialysis of GDP-beta-S. Either preincubation with pertussis toxin or application of the phosphatidylcholine (PC)-specific phospholipase C (PLC) inhibitor D609, but not the phosphatidylinositol (PI)-PLC inhibitor U73122, blocked the melatonin effect. The protein kinase C (PKC) activator PMA potentiated the glycine currents and in the presence of PMA melatonin failed to cause further potentiation of the currents, whereas application of the PKC inhibitor bisindolylmaleimide IV abolished the melatonin-induced potentiation. The melatonin effect persisted when [Ca(2+)](i) was chelated by BAPTA, and melatonin induced no increase in [Ca(2+)](i). Neither cAMP-PKA nor cGMP-PKG signalling pathways seemed to be involved because 8-Br-cAMP or 8-Br-cGMP failed to cause potentiation of the glycine currents and both the PKA inhibitor H-89 and the PKG inhibitor KT5823 did not block the melatonin-induced potentiation. In consequence, a distinct PC-PLC/PKC signalling pathway, following the activation of G(i/o)-coupled MT(2) receptors, is most likely responsible for the melatonin-induced potentiation of glycine currents of rat RGCs. Furthermore, in rat retinal slices melatonin potentiated light-evoked glycine receptor-mediated inhibitory postsynaptic currents in RGCs. These results suggest that melatonin, being at higher levels at night, may help animals to detect positive or negative contrast in night vision by modulating inhibitory signals largely mediated by glycinergic amacrine cells in the inner

  4. PLC VVVF Elevator Control System

    OpenAIRE

    Tang, Yujian; Gui, Tianyu

    2016-01-01

    The aim of the thesis is to introduce the PLC VVVF elevator and its control system. The thesis can be divided into three parts. The first part is about the overview of the lift: the kinds of the lift and the structure of the lift, it shows the knowledge about the components and the operating systems of the lift. The second part is about the PLC control system, it’s about the operations of the lift from the introduction about the hardware and software of the PLC control system. And the thi...

  5. Modeling a Consistent Behavior of PLC-Sensors

    Directory of Open Access Journals (Sweden)

    E. V. Kuzmin

    2014-01-01

    Full Text Available The article extends the cycle of papers dedicated to programming and verificatoin of PLC-programs by LTL-specification. This approach provides the availability of correctness analysis of PLC-programs by the model checking method.The model checking method needs to construct a finite model of a PLC program. For successful verification of required properties it is important to take into consideration that not all combinations of input signals from the sensors can occur while PLC works with a control object. This fact requires more advertence to the construction of the PLC-program model.In this paper we propose to describe a consistent behavior of sensors by three groups of LTL-formulas. They will affect the program model, approximating it to the actual behavior of the PLC program. The idea of LTL-requirements is shown by an example.A PLC program is a description of reactions on input signals from sensors, switches and buttons. In constructing a PLC-program model, the approach to modeling a consistent behavior of PLC sensors allows to focus on modeling precisely these reactions without an extension of the program model by additional structures for realization of a realistic behavior of sensors. The consistent behavior of sensors is taken into account only at the stage of checking a conformity of the programming model to required properties, i. e. a property satisfaction proof for the constructed model occurs with the condition that the model contains only such executions of the program that comply with the consistent behavior of sensors.

  6. Development of tools for automatic generation of PLC code

    CERN Document Server

    Koutli, Maria; Rochez, Jacques

    This Master thesis was performed at CERN and more specifically in the EN-ICE-PLC section. The Thesis describes the integration of two PLC platforms, that are based on CODESYS development tool, to the CERN defined industrial framework, UNICOS. CODESYS is a development tool for PLC programming, based on IEC 61131-3 standard, and is adopted by many PLC manufacturers. The two PLC development environments are, the SoMachine from Schneider and the TwinCAT from Beckhoff. The two CODESYS compatible PLCs, should be controlled by the SCADA system of Siemens, WinCC OA. The framework includes a library of Function Blocks (objects) for the PLC programs and a software for automatic generation of the PLC code based on this library, called UAB. The integration aimed to give a solution that is shared by both PLC platforms and was based on the PLCOpen XML scheme. The developed tools were demonstrated by creating a control application for both PLC environments and testing of the behavior of the code of the library.

  7. Data acquisition and control system with a programmable logic controller (PLC) for a pulsed chemical oxygen-iodine laser

    Science.gov (United States)

    Yu, Haijun; Li, Guofu; Duo, Liping; Jin, Yuqi; Wang, Jian; Sang, Fengting; Kang, Yuanfu; Li, Liucheng; Wang, Yuanhu; Tang, Shukai; Yu, Hongliang

    2015-02-01

    A user-friendly data acquisition and control system (DACS) for a pulsed chemical oxygen -iodine laser (PCOIL) has been developed. It is implemented by an industrial control computer,a PLC, and a distributed input/output (I/O) module, as well as the valve and transmitter. The system is capable of handling 200 analogue/digital channels for performing various operations such as on-line acquisition, display, safety measures and control of various valves. These operations are controlled either by control switches configured on a PC while not running or by a pre-determined sequence or timings during the run. The system is capable of real-time acquisition and on-line estimation of important diagnostic parameters for optimization of a PCOIL. The DACS system has been programmed using software programmable logic controller (PLC). Using this DACS, more than 200 runs were given performed successfully.

  8. Development of tools for automatic generation of PLC code

    OpenAIRE

    Koutli, Maria; Chasapis, Georgios; Rochez, Jacques

    2014-01-01

    This Master thesis was performed at CERN and more specifically in the EN-ICE-PLC section. The Thesis describes the integration of two PLC platforms, that are based on CODESYS development tool, to the CERN defined industrial framework, UNICOS. CODESYS is a development tool for PLC programming, based on IEC 61131-3 standard, and is adopted by many PLC manufacturers. The two PLC development environments are, the SoMachine from Schneider and the TwinCAT from Beckhoff. The two CODESYS compatible P...

  9. On Construction and Verification of PLC-Programs

    Directory of Open Access Journals (Sweden)

    E. V. Kuzmin

    2012-01-01

    Full Text Available We review some methods and approaches to programming discrete problems for Programmable Logic Controllers on the example of constructing PLC-programs for controling a code lock. For these approaches we evaluate the usability of the model checking method for the analysis of program correctness with respect to the automatic verification tool Cadence SMV. Some possible PLC-program vulnerabilities arising at a number approaches to programming of PLC are revealed.

  10. Identification of the Elusive Mammalian Enzyme Phosphatidylcholine-Specific Phospholipase C

    Science.gov (United States)

    2015-09-01

    Summary of Results. Task 1. To identify mammalian PC- PLC . Based on results published by other groups, we proposed to identify candidate PC- PLC mRNAs by...establishing the role of the elusive mammalian protein, phosphatidycholine- specific phospholipase C (PC- PLC ) in the inflammatory processes involved in...progression of rheumatoid arthritis (RA). Thus, the main scopes of this proposal are: 1. to identify the PC- PLC gene and protein; and 2. to test PC- PLC

  11. Úzkopásmová PLC komunikace se standardy G3-PLC, PRIME a IEEE-1901.2

    OpenAIRE

    Skrášek, Tomáš

    2015-01-01

    Diplomová práce pojednává o standardech úzkopásmové PLC komunikace. V teoretické části jsou popsány všechny dostupné OFDM standardy, mezi něž patří G3-PLC, PRIME, IEEE-1901.2 a G.hnem. Praktická část se zabývá standardy PRIME a G3-PLC. Dále je také porovnán systém OFDM se systémem komunikace na jedné nosné frekvenci v prostředí s reálným rušením. V poslední části je popsán návrh dvou firmware pro PLC modemy Texas Instruments TMDSPLCKIT-V3, které umožňují UART komunikaci a dálkový sběr dat. K ...

  12. PcToll2 positively regulates the expression of antimicrobial peptides by promoting PcATF4 translocation into the nucleus.

    Science.gov (United States)

    Lan, Jiang-Feng; Zhao, Li-Juan; Wei, Shun; Wang, Yuan; Lin, Li; Li, Xin-Cang

    2016-11-01

    Drosophila Toll and mammalian Toll-like receptors (TLRs) are a family of evolutionarily conserved immune receptors that play a crucial role in the first-line defense against intruded pathogens. Activating transcription factor 4 (ATF4), a member of the ATF/CREB transcription factor family, is an important factor that participates in TLR signaling and other physiological processes. However, in crustaceans, whether ATF4 homologs were involved in TLR signaling remains unclear. In the current study, we identified a Toll homolog PcToll2 and a novel ATF4 homolog PcATF4 from Procambarus clarkii, and analyzed the likely regulatory activity of PcATF4 in PcToll2 signaling. The complete cDNA sequence of PcToll2 was 4175 bp long containing an open reading frame of 2820 bp encoding a 939-amino acid protein, and the cDNA sequence of PcATF4 was 2027 bp long with an open reading frame of 1296 bp encoding a 431-amino acid protein. PcToll2 and human TLR4 shared the high identity and they were grouped into a cluster. Furthermore, PcToll2 had a close relationship with other shrimp TLRs that possessed potential antibacterial activity. PcToll2 was highly expressed in the hemocytes, heart and gills, while PcATF4 mainly distributed in gills. Upon challenge with Vibrio parahemolyticus, PcToll2 and PcATF4 together with the antimicrobial peptides of ALF1 and ALF2 were significantly up-regulated in the hemocytes, and the PcATF4 was translocated into the nucleus. After PcToll2 silencing and challenge with Vibrio, the translocation of PcATF4 into the nucleus was inhibited and the expression of ALF1 and ALF2 was reduced, but the expression of PcDorsal and PcSTAT was not affected. Furthermore, after PcATF4 knockdown and challenge with or without Vibrio, the expression of ALF1 and ALF2 was also decreased while the expression of PcToll2 was upregulated. These results suggested that PcToll2 might regulate the expression of ALF1 and ALF2 by promoting the import of PcATF4, instead of the routine

  13. Empirical P-L-C relations for delta Scuti stars

    International Nuclear Information System (INIS)

    Gupta, S.K.

    1978-01-01

    Separate P-L-C relations have been empirically derived by sampling the delta Scuti stars according to their pulsation modes. The results based on these relations have been compared with those estimated from the model based P-L-C relations and the other existing empirical P-L-C relations. It is found that a separate P-L-C relation for each pulsation mode provides a better correspondence with observations. (Auth.)

  14. Automatic production of Iodine-123 with PLC 135/U

    International Nuclear Information System (INIS)

    Moghaddam-Banaem, L.; Afarideh, H.

    2004-01-01

    In this project, the automatic system for production of Iodine-123 with PLC/135μ Siemens, which is designed and installed for the first time in Iran, is discussed. The PLC (Programmable Logic Controller) is used to control industrial processing, which is similar to a computer and consists of central processing unit and memory and Input/Output units. PLC receives input information from auxiliary units such as sensors, switches, etc. and software processes data in memory and then sends commands to output units such as relays, motors, etc.The target section in Iodine production consists of 8 stages. In order to be sure automation works properly the system can be operated both manually and automatically. First PLC checks Manual/Automatic switch and in the case of automatic mode, PLC runs the program in memory and processing is done automatically. For this purpose, PLC takes the value of pressures and temperatures from analog inputs and after processing them it sends commands to digital output to activate valves or vacuum pumps or heaters. In this paper the following subjects are discussed: 1) Production of Iodine 123 2) PLC structure and auxiliary boards 3) Sensors and actuators and their connection to PLC 4) Software flowchart

  15. Application of PLC in irradiation controlling system

    International Nuclear Information System (INIS)

    Qin Wenjuan; Lin Baoling; Wang Mingtao; Huang Daorong; Yao Qiuguo; Gao Weixiang; Yang Kun; Xue Changlin; Pu Jiangling

    2005-01-01

    To deal with the multiprogramming controlling system and computer gathering and printing measure data in Irradiation Station, we adopted Programmable Logic Controller (brief: PLC) instead of PCB to control Irradiation System. PLC improved the anti-jamming ability and debugged for convenience. (authors)

  16. Automated Formal Verification for PLC Control Systems

    CERN Multimedia

    Fernández Adiego, Borja

    2014-01-01

    Programmable Logic Controllers (PLCs) are widely used devices used in industrial control systems. Ensuring that the PLC software is compliant with its specification is a challenging task. Formal verification has become a recommended practice to ensure the correctness of the safety-critical software. However, these techniques are still not widely applied in industry due to the complexity of building formal models, which represent the system and the formalization of requirement specifications. We propose a general methodology to perform automated model checking of complex properties expressed in temporal logics (e.g. CTL, LTL) on PLC programs. This methodology is based on an Intermediate Model (IM), meant to transform PLC programs written in any of the languages described in the IEC 61131-3 standard (ST, IL, etc.) to different modeling languages of verification tools. This approach has been applied to CERN PLC programs validating the methodology.

  17. Translation of PLC Programs to x86 for Simulation and Verification

    CERN Document Server

    Sallai, Gyula

    2017-01-01

    PLC programs are written in special languages, variants of the languages defined in the IEC 61131 standard. These programs cannot be directly executed on personal computers (on x86 architecture). To perform simulation of the PLC program or diagnostics during development, either a real PLC or a PLC simulator has to be used. However, these solutions are often inflexible and they do not provide appropriate performance. By generating x86-representations (semantically equivalent programs which can be executed on PCs, e.g. written in C, C++ or Java) of the PLC programs, some of these challenges could be met. PLCverif is a PLC program verification tool developed at CERN which includes a parser for Siemens PLC programs. In this work, we describe a code generator based on this parser of PLCverif. This work explores the possibilities and challenges of generating programs in widely-used general purpose languages from PLC programs, and provides a proof-of-concept code generation implementation. The presented solution dem...

  18. A non-catalytic histidine residue influences the function of the metalloprotease of Listeria monocytogenes.

    Science.gov (United States)

    Forster, Brian M; Bitar, Alan Pavinski; Marquis, Hélène

    2014-01-01

    Mpl, a thermolysin-like metalloprotease, and PC-PLC, a phospholipase C, are synthesized as proenzymes by the intracellular bacterial pathogen Listeria monocytogenes. During intracellular growth, L. monocytogenes is temporarily confined in a membrane-bound vacuole whose acidification leads to Mpl autolysis and Mpl-mediated cleavage of the PC-PLC N-terminal propeptide. Mpl maturation also leads to the secretion of both Mpl and PC-PLC across the bacterial cell wall. Previously, we identified negatively charged and uncharged amino acid residues within the N terminus of the PC-PLC propeptide that influence the ability of Mpl to mediate the maturation of PC-PLC, suggesting that these residues promote the interaction of the PC-PLC propeptide with Mpl. In the present study, we identified a non-catalytic histidine residue (H226) that influences Mpl secretion across the cell wall and its ability to process PC-PLC. Our results suggest that a positive charge at position 226 is required for Mpl functions other than autolysis. Based on the charge requirement at this position, we hypothesize that this residue contributes to the interaction of Mpl with the PC-PLC propeptide.

  19. Two schemes for rapid generation of digital video holograms using PC cluster

    Science.gov (United States)

    Park, Hanhoon; Song, Joongseok; Kim, Changseob; Park, Jong-Il

    2017-12-01

    Computer-generated holography (CGH), which is a process of generating digital holograms, is computationally expensive. Recently, several methods/systems of parallelizing the process using graphic processing units (GPUs) have been proposed. Indeed, use of multiple GPUs or a personal computer (PC) cluster (each PC with GPUs) enabled great improvements in the process speed. However, extant literature has less often explored systems involving rapid generation of multiple digital holograms and specialized systems for rapid generation of a digital video hologram. This study proposes a system that uses a PC cluster and is able to more efficiently generate a video hologram. The proposed system is designed to simultaneously generate multiple frames and accelerate the generation by parallelizing the CGH computations across a number of frames, as opposed to separately generating each individual frame while parallelizing the CGH computations within each frame. The proposed system also enables the subprocesses for generating each frame to execute in parallel through multithreading. With these two schemes, the proposed system significantly reduced the data communication time for generating a digital hologram when compared with that of the state-of-the-art system.

  20. A Classification of PLC Models and Applications

    NARCIS (Netherlands)

    Mader, Angelika H.; Boel, R.; Stremersch, G.

    In the past years there is an increasing interest in analysing PLC applications with formal methods. The first step to this end is to get formal models of PLC applications. Meanwhile, various models for PLCs have already been introduced in the literature. In our paper we discuss several

  1. The operational benefits of integrated PC control of gamma irradiation plants

    International Nuclear Information System (INIS)

    Comben, M.; Stephens, P.

    1998-01-01

    Compared with the traditional PLC control systems used on many gamma irradiation plants, the semi-intelligent decision making capabilities of a fully integrated PC control system can bring many benefits to the plant operator. The authors will describe how plant operation is fully automatic with the PC control providing all the input-output data required to run the plant efficiently and safely. Detailed product tracking, with live on-screen data, can be incorporated to give both plant operator and product manufacturer complete confidence in the irradiation process. Advanced features such as on-line diagnostics and mechanical part failure prediction are also described. Also available is automated dosimetry, reducing the opportunity for human error, whilst at the same time saving on staff costs and providing highly professional dose validation reports and comprehensive routine dosimetry documentation. The benefits of PURIDEC's PC control system are not only available with its new plants. The system can be supplied as an upgrade to plants of all ages and design giving the current operator all the benefits described in the paper

  2. PLC control of 50 MW klystron modulators

    International Nuclear Information System (INIS)

    Shang Lei; Liu Gongfa; Chen Liping; Lu Yeming; Hong Jun; Zhang Yi; Zhao Feng

    2004-01-01

    Upgrade project of the 50 MW klystron modulators of Hefei Light Source (HLS) was firstly introduced. PLC control system of modulators was employed to replace the old control and monitor system, which was based on relay logic circuit and manual operation method. the PLC system becomes a sub system of the new EPICS control system of HLS. Constant-current, switch-mode and high voltage power supplies were adopted to replace the old 50 Hz power supplies. The technology of modulators was improved and operation was more reliable. The design method, hardware and software of PLC control of modulators were described and the performance was presented. (authors)

  3. The Integration of DCS I/O to an Existing PLC

    Science.gov (United States)

    Sadhukhan, Debashis; Mihevic, John

    2013-01-01

    At the NASA Glenn Research Center (GRC), Existing Programmable Logic Controller (PLC) I/O was replaced with Distributed Control System (DCS) I/O, while keeping the existing PLC sequence Logic. The reason for integration of the PLC logic and DCS I/O, along with the evaluation of the resulting system is the subject of this paper. The pros and cons of the old system and new upgrade are described, including operator workstation screen update times. Detail of the physical layout and the communication between the PLC, the DCS I/O and the operator workstations are illustrated. The complex characteristics of a central process control system and the plan to remove the PLC processors in future upgrades is also discussed.

  4. Realizace úzkopásmových PLC modemů

    OpenAIRE

    Kubíček, Lukáš

    2012-01-01

    Diplomová práce se věnuje úzkopásmové technologii přenosu dat el. sítí NN (PLC) a~možnostem jejího využití v senzorových sítích. Zabývá se jak strukturou a základními vlastnostmi PLC standardu, tak možnostmi jeho uplatnění v praxi. Hlavní částí této práce je realizace PLC sítě pomocí IO ST7570 firmy STMicroelectronics. Jako příklad praktického využití PLC technologie je tato síť připojena k počítači, ve kterém jsou data ze senzoru (wattmetru) připojenému k PLC modemu ukládána pomocí aplikace ...

  5. 78 FR 11976 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-02-21

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) RB211-524 series turbofan engines. That AD currently requires...-16724 (76 FR 40217, July 8, 2011), for all RR plc RB211-524 series turbofan engines. That AD required...

  6. 77 FR 6668 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-02-09

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc RB211-Trent 500 series turbofan engines. This AD requires a one-time inspection of... RB211- Trent 560A2-61 turbofan engines that have not complied with Rolls- Royce plc Service Bulletin No...

  7. Real time control “es-dawet” mixer using dasboard based on PLC and WSN

    Science.gov (United States)

    Siagian, Pandapotan; Hutauruk, Sindak; Kisno

    2017-09-01

    The aim of this study is to monitor and acquire the remote parameters like Speed control a DC Motor, IR Sensor, Temperature of pasteurize mix of ice cream, and send these real values over wireless network. A proposed system is dashboard monitoring system for PLC based system wirelessly using ZigBee protocol. To implement this a ZigBee model is connected to a programmed digital signal controller which would transmit the data to Zigbee coordinator which is connected to a PC through RS232 serial communication. Person can need only to send the reply about the process that is to be carried out and PLC will check the status of the web base sent by person and take the action according to it where wired communication is either more expensive or impossible due to physical conditions. A low cost system for measured the parameters of motor such as IR Sensor, Speed control a DC Motor by PWM and temperature with Zigbee protocol connectivity. A database is built to execute monitoring and to save the motor parameters received by radio frequency (RF) data acquisition system. Experimental results show that the proposed system is less costly, provides higher accuracy as well as safe and gives visual environment.

  8. PLC based control system for RAM assembly test facility

    International Nuclear Information System (INIS)

    Kulkarni, S.S.; Kumar, Vinaya; Chandra, Umesh

    1994-01-01

    The flexibility, expandability, ease of programming and diagnostic features makes the programmable logic controller (PLC) suitable for a variety of control applications in engineering system test facilities. A PLC based control system for RAM assembly test facility (RATF) and for testing the related hydraulic components is being developed and installed at BARC. This paper describes the approach taken for meeting the control requirements and illustrates the PLC software that has been developed. (author). 1 fig

  9. The application of PLC in 60Co container inspection system

    International Nuclear Information System (INIS)

    Huang Yibin; Xiang Xincheng

    2001-01-01

    The author discusses the interlock technique of 60 Co container inspection system, and introduces the hardware structure and program of interlock control system using PLC. Due to adopting PLC distributed control, the system works stably and reliably. The successful application of PLC in 60 Co container inspection system has some use for reference in nuclear technology field

  10. Parameters Evaluation of PLC Dependability and Safety

    Directory of Open Access Journals (Sweden)

    Juraj Zdansky

    2006-01-01

    Full Text Available This paper is focused on evaluation of dependability and safety parameters of PLC (Programmable Logic Controller. Achievement of requested level of these parameters is an application assumption for using PLC in control of safety critical processes. Evaluation of these parameters can be made on the base of suitable model and it can be influenced by system architecture when necessary.

  11. Automated turn pike using PLC and SCADA

    Science.gov (United States)

    Silpa Sreedhar, P.; Aiswarya, P.; Kathirvelan, J.

    2017-11-01

    We propose a smart turnpike based on Programmable Logic Controller (PLC) and Supervisory Control and Data Acquisition Systems (SCADA) in this paper. In this work, the basic idea is to measure the weight of the vehicles and classify them according to its weight to the respective lanes. It is difficult for the turnpike people to monitor the whole process all the time. So, this PLC based diversion system can be implemented in turnpikes to reduce the difficulties. This method will work based on weight sensors (piezo-resistive) whose output will be fed to a PLC, which will control the vehicle diversion. Using SCADA software, the whole process can be monitored from a remote area. The algorithm developed in this successfully installed in real time system.

  12. Power Line Communication (PLC) in Space - Current Status and Outlook

    Science.gov (United States)

    Wolf, J.

    2012-05-01

    The Power Line Communication (PLC) technology as known from various terrestrial applications, e.g. in building automation, in the automotive sector and on aircraft, appears to be a promising technology for the use on spacecraft. Starting from a critical overview on existing terrestrial PLC applications with their pros and cons, the paper gives a motivation for the introduction of the PLC technology on spacecraft, discusses the potential areas where it can be applied and is highlighting the potential problem areas. A short overview of on-going ESA PLC activities is provided and an outlook is given.

  13. PLC-based mode multi/demultiplexers for mode division multiplexing

    Science.gov (United States)

    Saitoh, Kunimasa; Hanzawa, Nobutomo; Sakamoto, Taiji; Fujisawa, Takeshi; Yamashita, Yoko; Matsui, Takashi; Tsujikawa, Kyozo; Nakajima, Kazuhide

    2017-02-01

    Recently developed PLC-based mode multi/demultiplexers (MUX/DEMUXs) for mode division multiplexing (MDM) transmission are reviewed. We firstly show the operation principle and basic characteristics of PLC-based MUX/DEMUXs with an asymmetric directional coupler (ADC). We then demonstrate the 3-mode (2LP-mode) multiplexing of the LP01, LP11a, and LP11b modes by using fabricated PLC-based mode MUX/DEMUX on one chip. In order to excite LP11b mode in the same plane, a PLC-based LP11 mode rotator is introduced. Finally, we show the PLC-based 6-mode (4LP-mode) MUX/DEMUX with a uniform height by using ADCs, LP11 mode rotators, and tapered waveguides. It is shown that the LP21a mode can be excited from the LP11b mode by using ADC, and the two nearly degenerated LP21b and LP02 modes can be (de)multiplexed separately by using tapered mode converter from E13 (E31) mode to LP21b (LP02) mode.

  14. Applying Model Checking to Industrial-Sized PLC Programs

    CERN Document Server

    AUTHOR|(CDS)2079190; Darvas, Daniel; Blanco Vinuela, Enrique; Tournier, Jean-Charles; Bliudze, Simon; Blech, Jan Olaf; Gonzalez Suarez, Victor M

    2015-01-01

    Programmable logic controllers (PLCs) are embedded computers widely used in industrial control systems. Ensuring that a PLC software complies with its specification is a challenging task. Formal verification has become a recommended practice to ensure the correctness of safety-critical software but is still underused in industry due to the complexity of building and managing formal models of real applications. In this paper, we propose a general methodology to perform automated model checking of complex properties expressed in temporal logics (\\eg CTL, LTL) on PLC programs. This methodology is based on an intermediate model (IM), meant to transform PLC programs written in various standard languages (ST, SFC, etc.) to different modeling languages of verification tools. We present the syntax and semantics of the IM and the transformation rules of the ST and SFC languages to the nuXmv model checker passing through the intermediate model. Finally, two real cases studies of \\CERN PLC programs, written mainly in th...

  15. Automatic control model of water filling system with Allen Bradley Micrologix 1400 PLC

    Science.gov (United States)

    Harahap, R.; Adyatma, AF; Fahmi, F.

    2018-02-01

    Programmable Logic Controller or PLC today plays an important role in most industrial control systems. PLC usage can be encountered in almost all fields of industry, not only in the manufacturing world but also on many other things such as elevators in office buildings, hotels hospitals, and others. PLC is an electronic control tool that operates in logic that its programming can be modified with relative ease. As with any controller in general, the PLC processes input signals to further discharge output according to the desired program. PLC usage is very broad because of its high reliability, can be reprogrammed or modified with relative ease, and very helpful in the tracking troubleshooting. One type of existing PLC is Allen Bradley PLC. Allen Bradley PLC program is commonly used in various industries. PLC Allen Bradley (AB) has several types, and one of them is the type of Micrologic 1400. In this study we design a system as a comparison with the conventional system. For that to explore the use of a PLC program which will be supported by a simulator tool, including a program to RSLogic 500, how to programming, monitoring via RSView32, and modification. It is expected to understand the application aspect of operation and programming of this specific PLC and its potential. The purpose of this research is to design water filling automation system by using Allen Bradley Micrologic 1400 type 1766-L32BXB PLC, empowering the use of Allen Bradley Micrologic 1400 PLC and to regulate the desired process to obtain efficiency and effectiveness compared with conventional system arrangement using Relay.

  16. Transacsys PLC - Final Results

    CERN Multimedia

    2002-01-01

    Final results from Transacsys PLC. A subsidary of this company was set up to develop the CERN EDH system into a commercial product but incurred too much financial loss so the project was cancelled (1/2 page).

  17. Electromagnetic compatibility of PLC adapters for in-home/domestic networks

    Science.gov (United States)

    Potisk, Lukas; Hallon, Jozef; Orgon, Milos; Fujdiak, Radek

    2018-01-01

    The use of programable logic controllers (PLC) technology in electrical networks 230 V causes electromagnetic radiation that interferes with other electrical equipment connected to the network [1-4]. Therefore, this article describes the issues of electromagnetic compatibility (EMC) of new PLC adapters used in IP broadband services in a multi-user environment. The measurements of disturbing electromagnetic field originated in PLC adapters were made in a certified laboratory EMC (laboratory of electromagnetic compatibility) in the Institute of Electrical Engineering at Faculty of Electrical Engineering and Information Technology of the Slovak University of Technology in Bratislava. The measured spectra of the radiated electromagnetic field will be compared with the results obtained when testing older PLC modems [5].

  18. Optical interconnection for a polymeric PLC device using simple positional alignment.

    Science.gov (United States)

    Ryu, Jin Hwa; Kim, Po Jin; Cho, Cheon Soo; Lee, El-Hang; Kim, Chang-Seok; Jeong, Myung Yung

    2011-04-25

    This study proposes a simple cost-effective method of optical interconnection between a planar lightwave circuit (PLC) device chip and an optical fiber. It was conducted to minimize and overcome the coupling loss caused by lateral offset which is due to the process tolerance and the dimensional limitation existing between PLC device chips and fiber array blocks with groove structures. A PLC device chip and a fiber array block were simultaneously fabricated in a series of polymer replication processes using the original master. The dimensions (i.e., width and thickness) of the under-clad of the PLC device chip were identical to those of the fiber array block. The PLC device chip and optical fiber were aligned by simple positional control for the vertical direction of the PLC device chip under a particular condition. The insertion loss of the proposed 1 x 2 multimode optical splitter device interconnection was 4.0 dB at 850 nm and the coupling loss was below 0.1 dB compared with single-fiber based active alignment.

  19. Practical application with plc in manipulation of a robotic arm

    Directory of Open Access Journals (Sweden)

    Cristian Barz

    2014-12-01

    Full Text Available This paper presents the use of a robotic arm PLC Siemens in order not using CNC commands. This is done by programming the PLC ladder diagram language that makes movement on the three axes of the arm by means of stepper motors. Required command console PLC is built with the help of a touch screen HMI Weintek. In the user interface are introduced distances and displacement speeds on the three axes.

  20. Reliability Analysis for Safety Grade PLC(POSAFE-Q)

    International Nuclear Information System (INIS)

    Choi, Kyung Chul; Song, Seung Whan; Park, Gang Min; Hwang, Sung Jae

    2012-01-01

    Safety Grade PLC(Programmable Logic Controller), POSAFE-Q, was developed recently in accordance with nuclear regulatory and requirements. In this paper, describe reliability analysis for digital safety grade PLC (especially POSAFE-Q). Reliability analysis scope is Prediction, Calculation of MTBF (Mean Time Between Failure), FMEA (Failure Mode Effect Analysis), PFD (Probability of Failure on Demand). (author)

  1. Full-automatic Special Drill Hydraulic System and PLC Control

    Directory of Open Access Journals (Sweden)

    Tian Xue Jun

    2016-01-01

    Full Text Available A hydraulic-driven and PLC full-automatic special drill is introduced, working principle of the hydraulic system and PLC control system are analyzed and designed, this equipment has the advantages of high efficiency, superior quality and low cost etc.

  2. Living Color Frame System: PC graphics tool for data visualization

    Science.gov (United States)

    Truong, Long V.

    1993-01-01

    Living Color Frame System (LCFS) is a personal computer software tool for generating real-time graphics applications. It is highly applicable for a wide range of data visualization in virtual environment applications. Engineers often use computer graphics to enhance the interpretation of data under observation. These graphics become more complicated when 'run time' animations are required, such as found in many typical modern artificial intelligence and expert systems. Living Color Frame System solves many of these real-time graphics problems.

  3. Efficient Implementation of a Symbol Timing Estimator for Broadband PLC.

    Science.gov (United States)

    Nombela, Francisco; García, Enrique; Mateos, Raúl; Hernández, Álvaro

    2015-08-21

    Broadband Power Line Communications (PLC) have taken advantage of the research advances in multi-carrier modulations to mitigate frequency selective fading, and their adoption opens up a myriad of applications in the field of sensory and automation systems, multimedia connectivity or smart spaces. Nonetheless, the use of these multi-carrier modulations, such as Wavelet-OFDM, requires a highly accurate symbol timing estimation for reliably recovering of transmitted data. Furthermore, the PLC channel presents some particularities that prevent the direct use of previous synchronization algorithms proposed in wireless communication systems. Therefore more research effort should be involved in the design and implementation of novel and robust synchronization algorithms for PLC, thus enabling real-time synchronization. This paper proposes a symbol timing estimator for broadband PLC based on cross-correlation with multilevel complementary sequences or Zadoff-Chu sequences and its efficient implementation in a FPGA; the obtained results show a 90% of success rate in symbol timing estimation for a certain PLC channel model and a reduced resource consumption for its implementation in a Xilinx Kyntex FPGA.

  4. Efficient Implementation of a Symbol Timing Estimator for Broadband PLC

    Directory of Open Access Journals (Sweden)

    Francisco Nombela

    2015-08-01

    Full Text Available Broadband Power Line Communications (PLC have taken advantage of the research advances in multi-carrier modulations to mitigate frequency selective fading, and their adoption opens up a myriad of applications in the field of sensory and automation systems, multimedia connectivity or smart spaces. Nonetheless, the use of these multi-carrier modulations, such as Wavelet-OFDM, requires a highly accurate symbol timing estimation for reliably recovering of transmitted data. Furthermore, the PLC channel presents some particularities that prevent the direct use of previous synchronization algorithms proposed in wireless communication systems. Therefore more research effort should be involved in the design and implementation of novel and robust synchronization algorithms for PLC, thus enabling real-time synchronization. This paper proposes a symbol timing estimator for broadband PLC based on cross-correlation with multilevel complementary sequences or Zadoff-Chu sequences and its efficient implementation in a FPGA; the obtained results show a 90% of success rate in symbol timing estimation for a certain PLC channel model and a reduced resource consumption for its implementation in a Xilinx Kyntex FPGA.

  5. Silica-based PLC with heterogeneously-integrated PDs for one-chip DP-QPSK receiver.

    Science.gov (United States)

    Kurata, Yu; Nasu, Yusuke; Tamura, Munehisa; Kasahara, Ryoichi; Aozasa, Shinichi; Mizuno, Takayuki; Yokoyama, Haruki; Tsunashima, Satoshi; Muramoto, Yoshifumi

    2012-12-10

    To realize a DP-QPSK receiver PLC, we heterogeneously integrated eight high-speed PDs on a silica-based PLC platform with a PBS, 90-degree optical hybrids and a VOA. The use of a 2.5%-Δ waveguide reduced the receiver PLC size to 11 mm x 11 mm. We successfully demonstrated 32 Gbaud DP-QPSK signal demodulation with the receiver PLC.

  6. Control Systems of Rubber Dryer Machinery Components Using Programmable Logic Control (PLC)

    Science.gov (United States)

    Hendra; Yulianto, A. S.; Indriani, A.; Hernadewita; Hermiyetti

    2018-02-01

    Application of programmable logic control (PLC) is widely used on the control systems in the many field engineering such as automotive, aviation, food processing and other industries [1-2]. PLC is simply program to control many automatic activity, easy to use, flexible and others. PLC using the ladder program to solve and regulated the control system component. In previous research, PLC was used for control system of rotary dryer machine. In this paper PLC are used for control system of motion component in the rubber dryer machinery. Component of rubber dryer machine is motors, gearbox, sprocket, heater, drying chamber and bearing. Principle working of rubber dryer machinery is wet rubber moving into the drying chamber by sprocket. Sprocket is driven by motors that conducted by PLC to moving and set of wet rubber on the drying chamber. Drying system uses greenhouse effect by making hanger dryer design in the form of line path. In this paper focused on motion control system motors and sensors drying rubber using PLC. The results show that control system of rubber dryer machinery can work in accordance control input and the time required to dry the rubber.

  7. Development of Multipurpose PLC trainer for the simulator of reactor safety system

    International Nuclear Information System (INIS)

    Syaiful Bakhri; Deswandri; Ahmad Abtokhi

    2014-01-01

    PLC becomes one of the essential components for the current type of reactor which based on digital instrumentation and control. Several studies have demonstrated the promising results including the implementation of PLC's for RSG-GAS research reactor. However, research for the safety and reliability analysis can not be carried out freely in the existing systems.Therefore, this research aims to develop a PLC trainer employing micro PLC OMRON CP1MA which can be useful for simulator of various topics in reactor safety. Two experimental tests were carried out to show the PLC’s performances. The first experimental testing implementing reactor protection system of research reactor RSG-GAS shows the capacity of PLC system to identify the initiator of the SCRAM logic as well as giving a promptly response. Secondly, the application of PLC to controls the water level in dual reservoir system simulation, demonstrates the simplicity of the operation and design while maintaining the best performances. (author)

  8. A study of PLC system vulnerability checklists in nuclear power plants

    International Nuclear Information System (INIS)

    Cha, Ki Jong; Cho, Gi Ho; Ahn, Jaeh Young; Kim, Young Mi; Kwon, Yong Il

    2012-01-01

    Because the design of the PLCs (Programmable Logic Controller) in the I and C (Instrument and Control) systems for NPP (Nuclear Power Plant) were carried out independently, the problems of cyber security were not addressed in the PLC system designs. Recently, the analysis and the countermeasure development for the PLC systems became mandatory due to the developments in cyber attack techniques and the increasingly revealed vulnerability to such attacks. A comparative analysis on the cyber security checklist of PLC in industry control system and in NPP systems was carried out, and in this paper, the cyber security regulatory trend and the PLC usage status are described

  9. A study of PLC system vulnerability checklists in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Ki Jong; Cho, Gi Ho; Ahn, Jaeh Young [Convergence technology Research Commercialization Center, Daejeon (Korea, Republic of); Kim, Young Mi; Kwon, Yong Il [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2012-10-15

    Because the design of the PLCs (Programmable Logic Controller) in the I and C (Instrument and Control) systems for NPP (Nuclear Power Plant) were carried out independently, the problems of cyber security were not addressed in the PLC system designs. Recently, the analysis and the countermeasure development for the PLC systems became mandatory due to the developments in cyber attack techniques and the increasingly revealed vulnerability to such attacks. A comparative analysis on the cyber security checklist of PLC in industry control system and in NPP systems was carried out, and in this paper, the cyber security regulatory trend and the PLC usage status are described.

  10. Using of Finite Automation at Programming PLC

    Directory of Open Access Journals (Sweden)

    Karol Rastocny

    2004-01-01

    Full Text Available The paper is concerning with systematic advances at programming programmable logic controllers (PLC, which comes out from algebraic description of behaviour of sequential circuit, in the way of finite automaton. This kind of access is streamlining the work of a programmer and enabling to use formalisms in the of whole process of system development, that is from process of analysing demands to process of verification and validation created program. The paper considers about using of ladder diagram at programming PLC.

  11. Webová aplikace v PLC PFC200

    OpenAIRE

    Michalík, David

    2017-01-01

    Tato bakalářská práce se věnuje implementaci vlastního způsobu ovládání vstupů, výstupů a paměti PLC PFC200 od firmy WAGO pomocí dynamického webového rozhraní. Součástí práce je popis PLC, způsobů jeho ovládání, rešerše volně dostupných webových serverů pro Linux a popis metod pro vytvoření real-time ovládání. Výstupem je webová aplikace běžící na webovém serveru v PLC, využívající vlastní runtime systém formou daemon programů. This bachelor’s thesis is mainly focused on implementation of ...

  12. Programmable logic controller (PLC) for safety systems of nuclear plants

    International Nuclear Information System (INIS)

    Sen, S.K.; Karmakar, G.; Joseph, Jose; Patil, R.K.

    2002-01-01

    Full text: A programmable logic controller (PLC) has been developed by RCnD, BARC for use in the safety critical systems in nuclear power plants. This PLC uses qualified hardware developed in RCnD for use in NPP. The programming software conforms to IEC-61131 part 3. The application programming is done on function block diagram (FBD) editor and the FBD is automatically converted into code in high level language (C / C++). This feature makes the application easily decipherable and therefore easily subjected to reviews and other validation techniques. The key to make quality software for use in nuclear systems is to enforce various standards in the design and development of the software, something, which is not possible to do with a commercially available PLC. This PLC with its software completely transparent lends itself to rigorous verification and validation easily

  13. Trends in Control Area of PLC Reliability and Safety Parameters

    Directory of Open Access Journals (Sweden)

    Juraj Zdansky

    2008-01-01

    Full Text Available Extension of the PLC application possibilities is closely related to increase of reliability and safety parameters. If the requirement of reliability and safety parameters will be suitable, the PLC could by implemented to specific applications such the safety-related processes control. The goal of this article is to show the way which producers are approaching to increase PLC`s reliability and safety parameters. The second goal is to analyze these parameters for range of present choice and describe the possibility how the reliability and safety parameters can be affected.

  14. Analysis of the PLC object model in the PF linac

    International Nuclear Information System (INIS)

    Abe, Isamu; Shirakawa, Akihiro; Nakahara, Kazuo; Tanaka, Masahiko

    1995-01-01

    Device controllers (front end) for the KEK PF Linac, which has been operated for more than ten years, had to be renewed, because there is no longer support from hardware manufacturer. To reduce maintenance costs, device controllers are planed to be replaced by PLC (Programmable Logic Controller). Investigations launched in the late 1994s for the PLC have carried out in order to make sure of the I/O stability and network possibilities. In this paper, the software for the PLC is discussed based on the OOP concept. (author)

  15. Development of radioactive source scanner based on PLC

    International Nuclear Information System (INIS)

    Yang Guogui; Gao Xiang; Guo Hongli

    2013-01-01

    The radioactive radial uniformity of 68 Ge line radioactive sources is a critical quality parameter. The radioactive source scanner with linear scanning function is developed by making use of high-speed pulse counters, high-speed pulse output ports, and the powerful instruction system of Siemens S7-200 series programmable logic controller (PLC). A computer used as a host computer of the instrument communicate with. the PLC by point to point interface (PPI) protocol, The instrument with functions of data collection, transmission, displaying, saving, motion control and instrument parameter settings, can be used to measure the radioactive radial uniformity and total activity of line radioactive source. The advantages of Using the PLC to develop nuclear instrumentation are development speed, strong anti-interference ability, and low-cost. This paper mainly describes the control system implementation and feature of the instrument. (authors)

  16. Úzkopásmová PLC komunikace pro Smart Metering

    OpenAIRE

    Kubů, Jiří

    2016-01-01

    Tato bakalářská práce se zabývá úzkopásmovou PLC komunikací. V práci je popsán základní princip, rozdělení PLC komunikace, historie technologie, využívané komunikační standardy a rušení ovlivňující datovou komunikaci této technologie. V rámci této práce byly provedeny i experimentální měření v reálném prostředí s modemy od firmy Texas Instruments C2000 PLC TMDSPLCKITV4 a C2000 PLC TMDSPLCKIT-V3. Výsledky tohoto měření jsou reálné přenosové rychlosti. Dále byla vytvořena aplikace pro dálkový s...

  17. Construction and Verification of PLC LD-programs by LTL-specification

    Directory of Open Access Journals (Sweden)

    E. V. Kuzmin

    2013-01-01

    Full Text Available An approach to construction and verification of PLC LD-programs for discrete problems is proposed. For the specification of the program behavior, we use the linear-time temporal logic LTL. Programming is carried out in the LD-language (Ladder Diagram according to an LTL-specification. The correctness analysis of an LTL-specification is carried out by the symbolic model checking tool Cadence SMV. A new approach to programming and verification of PLC LD-programs is shown by an example. For a discrete problem, we give a LD-program, its LTL-specification and an SMV-model. The purpose of the article is to describe an approach to programming PLC, which would provide a possibility of LD-program correctness analysis by the model checking method. Under the proposed approach, the change of the value of each program variable is described by a pair of LTL-formulas. The first LTL-formula describes situations which increase the value of the corresponding variable, the second LTL-formula specifies conditions leading to a decrease of the variable value. The LTL-formulas (used for speci- fication of the corresponding variable behavior are constructive in the sense that they construct the PLC-program (LD-program, which satisfies temporal properties expressed by these formulas. Thus, the programming of PLC is reduced to the construction of LTLspecification of the behavior of each program variable. In addition, an SMV-model of a PLC LD-program is constructed according to LTL-specification. Then, the SMV-model is analysed by the symbolic model checking tool Cadence SMV.

  18. PLC/DTAM Software Programs for Pumping Instrumentation and Control Skid X

    International Nuclear Information System (INIS)

    HORNER, T.M.

    2001-01-01

    This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''X''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines will be tailored for each individual BY-farm skid. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for BY-105 pumping. This document represents the final PLC and DTAM programs for PIC skid ''X'' at BY-105. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  19. 77 FR 13485 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-03-07

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... series turbofan engines. This AD requires inspecting the front combustion liner head section for cracking.... (c) Applicability This AD applies to Rolls-Royce plc (RR) RB211-Trent 800 turbofan engines, all...

  20. Targeting annexin A7 by a small molecule suppressed the activity of phosphatidylcholine-specific phospholipase C in vascular endothelial cells and inhibited atherosclerosis in apolipoprotein E⁻/⁻mice.

    Science.gov (United States)

    Li, H; Huang, S; Wang, S; Zhao, J; Su, L; Zhao, B; Zhang, Y; Zhang, S; Miao, J

    2013-09-19

    Phosphatidylcholine-specific phospholipase C (PC-PLC) is a key factor in apoptosis and autophagy of vascular endothelial cells (VECs), and involved in atherosclerosis in apolipoprotein E⁻/⁻ (apoE⁻/⁻) mice. But the endogenous regulators of PC-PLC are not known. We recently found a small chemical molecule (6-amino-2, 3-dihydro-3-hydroxymethyl-1, 4-benzoxazine, ABO) that could inhibit oxidized low-density lipoprotein (oxLDL)-induced apoptosis and promote autophagy in VECs, and further identified ABO as an inhibitor of annexin A7 (ANXA7) GTPase. Based on these findings, we hypothesize that ANXA7 is an endogenous regulator of PC-PLC, and targeting ANXA7 by ABO may inhibit atherosclerosis in apoE⁻/⁻ mice. In this study, we tested our hypothesis. The results showed that ABO suppressed oxLDL-induced increase of PC-PLC level and activity and promoted the co-localization of ANXA7 and PC-PLC in VECs. The experiments of ANXA7 knockdown and overexpression demonstrated that the action of ABO was ANXA7-dependent in cultured VECs. To investigate the relation of ANXA7 with PC-PLC in atherosclerosis, apoE⁻/⁻ mice fed with a western diet were treated with 50 or 100 mg/kg/day ABO. The results showed that ABO decreased PC-PLC levels in the mouse aortic endothelium and PC-PLC activity in serum, and enhanced the protein levels of ANXA7 in the mouse aortic endothelium. Furthermore, both dosages of ABO significantly enhanced autophagy and reduced apoptosis in the mouse aortic endothelium. As a result, ABO significantly reduced atherosclerotic plaque area and effectively preserved a stable plaques phenotype, including reduced lipid deposition and pro-inflammatory macrophages, increased anti-inflammatory macrophages, collagen content and smooth muscle cells, and less cell death in the plaques. In conclusion, ANXA7 was an endogenous regulator of PC-PLC, and targeting ANXA7 by ABO inhibited atherosclerosis in apoE⁻/⁻ mice.

  1. Modelling and Formal Verification of Timing Aspects in Large PLC Programs

    CERN Document Server

    Fernandez Adiego, B; Blanco Vinuela, E; Tournier, J-C; Gonzalez Suarez, V M; Blech, J O

    2014-01-01

    One of the main obstacle that prevents model checking from being widely used in industrial control systems is the complexity of building formal models out of PLC programs, especially when timing aspects need to be integrated. This paper brings an answer to this obstacle by proposing a methodology to model and verify timing aspects of PLC programs. Two approaches are proposed to allow the users to balance the trade-off between the complexity of the model, i.e. its number of states, and the set of specifications possible to be verified. A tool supporting the methodology which allows to produce models for different model checkers directly from PLC programs has been developed. Verification of timing aspects for real-life PLC programs are presented in this paper using NuSMV.

  2. 77 FR 73268 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-12-10

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... certain Rolls-Royce plc (RR) RB211-Trent 900 series turbofan engines. This AD requires inspection of the... turbofan engines, all serial numbers. (d) Reason This AD was prompted by a Trent 900 engine experiencing a...

  3. 77 FR 56760 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-09-14

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc (RR) RB211-Trent 800 series turbofan engines. This AD requires removing from...-17, 892-17, 892B-17, and 895-17 turbofan engines that have an intermediate pressure (IP) turbine disc...

  4. Totalitäre Regimes

    OpenAIRE

    Merkel, Wolfgang

    2004-01-01

    "The development of the term and the analytical concept of totalitarianism have gone through several stages since the 1920s. However, even in its most sophisticated form, the version seen in Friedrich/ Brzezinski, the concept exhibits substantial systematic classification problems and analytical weaknesses. This article attempts to frame the type of totalitarian regime within a general typology of political regimes. Special attention is dedicated to the problem of distinguishing autocra...

  5. Development of an Adaptive Forecasting System: A Case Study of a PC Manufacturer in South Korea

    Directory of Open Access Journals (Sweden)

    Chihyun Jung

    2016-03-01

    Full Text Available We present a case study of the development of an adaptive forecasting system for a leading personal computer (PC manufacturer in South Korea. It is widely accepted that demand forecasting for products with short product life cycles (PLCs is difficult, and the PLC of a PC is generally very short. The firm has various types of products, and the volatile demand patterns differ by product. Moreover, we found that different departments have different requirements when it comes to the accuracy, point-of-time and range of the forecasts. We divide the demand forecasting process into three stages depending on the requirements and purposes. The systematic forecasting process is then introduced to improve the accuracy of demand forecasting and to meet the department-specific requirements. Moreover, a newly devised short-term forecasting method is presented, which utilizes the long-term forecasting results of the preceding stages. We evaluate our systematic forecasting methods based on actual sales data from the PC manufacturer, where our forecasting methods have been implemented.

  6. Emulation of Narrowband Powerline Data Transmission Channels and Evaluation of PLC Systems

    OpenAIRE

    Liu, Wenqing

    2013-01-01

    This work proposes advanced emulation of the physical layer behavior of NB-PLC channels and the application of a channel emulator for the evaluation of NB-PLC systems. In addition, test procedures and reference channels are proposed to improve efficiency and accuracy in the system evaluation and classification. This work shows that the channel emulator-based solution opens new ways toward flexible, reliable and technology-independent performance assessment of PLC modems.

  7. 78 FR 17297 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-03-21

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) RB211 Trent 500 series turbofan engines. That AD currently requires... 9, 2012), for all RR RB211 Trent 500 series turbofan engines. That AD requires a one-time inspection...

  8. Silencing of the tomato phosphatidylinositol-phospholipase C2 (SlPLC2) reduces plant susceptibility to Botrytis cinerea

    NARCIS (Netherlands)

    Gonorazky, Gabriela; Guzzo, María Carla; Abd-El-Haliem, Ahmed M.; Joosten, Matthieu H.A.J.; Laxalt, Ana María

    2016-01-01

    The tomato [Solanum lycopersicum (Sl)] phosphatidylinositol-phospholipase C (PI-PLC) gene family is composed of six members, named SlPLC1 to SlPLC6, differentially regulated on pathogen attack. We have previously shown that the fungal elicitor xylanase induces a raise of SlPLC2 and SlPLC5

  9. The YvfTU Two-component System is involved in plcR expression in Bacillus cereus

    Directory of Open Access Journals (Sweden)

    Nguyen-the Christophe

    2008-10-01

    Full Text Available Abstract Background Most extracellular virulence factors produced by Bacillus cereus are regulated by the pleiotropic transcriptional activator PlcR. Among strains belonging to the B. cereus group, the plcR gene is always located in the vicinity of genes encoding the YvfTU two-component system. The putative role of YvfTU in the expression of the PlcR regulon was therefore investigated. Results Expression of the plcR gene was monitored using a transcriptional fusion with a lacZ reporter gene in a yvfTU mutant and in its B. cereus ATCC 14579 parental strain. Two hours after the onset of the stationary phase, a stage at which the PlcR regulon is highly expressed, the plcR expression in the yvfTU mutant was only 50% of that of its parental strain. In addition to the reduced plcR expression in the yvfTU mutant, a few members of the PlcR regulon showed a differential expression, as revealed by transcriptomic and proteomic analyses. The virulence of the yvfTU mutant in a Galleria mellonella insect model was slightly lower than that of the parental strain. Conclusion The YvfTU two-component system is not required for the expression of most of the virulence factors belonging to the PlcR regulon. However, YvfTU is involved in expression of plcR, a major regulator of virulence in B. cereus.

  10. 77 FR 32007 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-05-31

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... all Rolls-Royce plc (RR) RB211-Trent 800 series turbofan engines. This AD requires removal from...-17, 877- 17, 884-17, 884B-17, 892-17, 892B-17, and 895-17 turbofan engines. (d) Reason This AD was...

  11. 78 FR 6749 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-01-31

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (AD) for all Rolls-Royce plc (RR) models RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines... 772B-60 turbofan engines. (d) Reason This AD was prompted by low-pressure (LP) compressor blade partial...

  12. Upgradation in SCADA and PLC of existing LN_2 control system for SST-1

    International Nuclear Information System (INIS)

    Panchal, Pradip; Mahesuria, Gaurang; Panchal, Rohit; Patel, Rakesh; Sonara, Dashrath; Pitroda, Dipen; Nimavat, Hiren; Tanna, Vipul; Pradhan, Subrata

    2016-01-01

    Highlights: • The control system of LN_2 Management System of SST-1 is designed on PLC and SCADA. • The implementation and results of up-gradation in PLC and SCADA are reported. • The up-gradation in PLC and SCADA has improved the reliability & availability of SST-1 LN_2 system. - Abstract: Helium Refrigerator/Liquefier system of Steady State Superconducting Tokamak (SST-1) incorporates Liquid Nitrogen (LN_2) pre-cooling system. LN_2 is used for 80 K thermal shields of SST-1, current feeder system and integrated flow distribution and control system. The LN_2 management system is distributed system and requires automatic control. Initially LN_2 control system had Citect based Supervisory Control and Data Acquisition (SCADA) and Koyo make Programmable Logic Controller (PLC). With the passage of time and due to unavailability of their hardware, it is being obsoleted. So, the requirements of new PLC and SCADA systems have been envisaged to make uninterruptable operation of SST-1 cryogenic system. Therefore, Wonderware SCADA and Schneider Electric make PLC is programmed to replace Citect SCADA and Koyo PLC. New control features have been added in upgraded control system for better management of LN_2 system. This upgradation of SCADA and PLC is completed, tested successfully and in operation. Operational performance highlights of the new upgraded system are presented in this paper.

  13. Development and Application of POSAFE-Q PLC Platform

    International Nuclear Information System (INIS)

    Lee, MyeongKyun; Song, SeungWhan; Yun, DongHwa

    2012-01-01

    The Safety-grade Programmable Logic Controller (PLC) Platform named POSAFE-Q was developed so that it meets the requirements of the Safety Class 1E, Quality Class 1, and Seismic Category I. Development process of the POSAFE-Q software developed in accordance with software life cycles. The POSAFE-Q meets safety and suitability for design are based on digital I and C laws, guidelines and technical standards. The POSAFE-Q PLC obtained approval for Topical Report from the Nuclear Safety and Security Commission in Korea. (author)

  14. Towards Designing PLC Networks for Ubiquitous Connectivity in Enterprises

    OpenAIRE

    Ali, Kamran; Pefkianakis, Ioannis; Liu, Alex X.; Kim, Kyu-Han

    2016-01-01

    Powerline communication (PLC) provides inexpensive, secure and high speed network connectivity, by leveraging the existing power distribution networks inside the buildings. While PLC technology has the potential to improve connectivity and is considered a key enabler for sensing, control, and automation applications in enterprises, it has been mainly deployed for improving connectivity in homes. Deploying PLCs in enterprises is more challenging since the power distribution network is more com...

  15. Application of PLC in the crane control system of MJTR

    International Nuclear Information System (INIS)

    Li Ziqiang; Ji Xiangdong

    2004-01-01

    The paper describes the application of PLC (Programmable Controller) in the control system of the bridge crane. PLC is the essential part of the control system, which uses some equipment such as frequency transformer and photoelectric switch to implement remote, manual and automatic centering functions. This paper emphasizes the programming of the automatic hole centering

  16. Wavelet-OFDM Signal Transmission Characteristics with High-Speed PLC Modem

    Science.gov (United States)

    Nakagawa, Kenichi; Tokuda, Masamitsu; Igata, Yuji

    In this paper, we measured the interference immunity characteristics of high-speed PLC system using Wavelet-OFDM when the narrowband conducted interference wave signal was injected. As the results, it was clear that (1) measured PHY rate at the all frequency band hardly decreased in C/I (Carrier to Interference ratio) of above 20dB, but began to decrease rapidly in C/I of below 0dB when the interference signal was injected in the frequency band of high-speed PLC signal, (2) when C/I became from 0dB to -20dB, the measured PHY rate at the frequency existing the notch band were improved around 10Mbps than that at the frequency not existing the notch band, (3) when the narrowband interference wave was injected outside of frequency band of high-speed PLC signal, the measured PHY rate did not decrease than that in each notch band. Therefore, it was revealed that high-speed PLC system using Wavelet-OFDM had good interference immunity characteristics.

  17. Iron-Regulated Phospholipase C Activity Contributes to the Cytolytic Activity and Virulence of Acinetobacter baumannii.

    Directory of Open Access Journals (Sweden)

    Steven E Fiester

    Full Text Available Acinetobacter baumannii is an opportunistic Gram-negative pathogen that causes a wide range of infections including pneumonia, septicemia, necrotizing fasciitis and severe wound and urinary tract infections. Analysis of A. baumannii representative strains grown in Chelex 100-treated medium for hemolytic activity demonstrated that this pathogen is increasingly hemolytic to sheep, human and horse erythrocytes, which interestingly contain increasing amounts of phosphatidylcholine in their membranes. Bioinformatic, genetic and functional analyses of 19 A. baumannii isolates showed that the genomes of each strain contained two phosphatidylcholine-specific phospholipase C (PC-PLC genes, which were named plc1 and plc2. Accordingly, all of these strains were significantly hemolytic to horse erythrocytes and their culture supernatants tested positive for PC-PLC activity. Further analyses showed that the transcriptional expression of plc1 and plc2 and the production of phospholipase and thus hemolytic activity increased when bacteria were cultured under iron-chelation as compared to iron-rich conditions. Testing of the A. baumannii ATCC 19606T plc1::aph-FRT and plc2::aph isogenic insertion derivatives showed that these mutants had a significantly reduced PC-PLC activity as compared to the parental strain, while testing of plc1::ermAM/plc2::aph demonstrated that this double PC-PLC isogenic mutant expressed significantly reduced cytolytic and hemolytic activity. Interestingly, only plc1 was shown to contribute significantly to A. baumannii virulence using the Galleria mellonella infection model. Taken together, our data demonstrate that both PLC1 and PLC2, which have diverged from a common ancestor, play a concerted role in hemolytic and cytolytic activities; although PLC1 seems to play a more critical role in the virulence of A. baumannii when tested in an invertebrate model. These activities would provide access to intracellular iron stores this pathogen

  18. Machine interlock and protection system based on PLC for the SSRF linac

    International Nuclear Information System (INIS)

    Chou Wenjun; Zhou Dayong; Chen Jianfeng; Shen Liren; Liu Yajuan

    2008-01-01

    This paper describes a machine interlock and protection system used for accelerators based on EPICS (Experimental physics and industrial control system). The system is composed of a front-end computer and an FM-3R logic controller PLC. The alarm signal is passed by the hardware directly, and would be deal with PLC. The reporting, recording and analyst of the event are accomplished by EPICS control software. And PLC is linked to the EPICS by Internet. (authors)

  19. 77 FR 75831 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-12-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... certain serial numbers (S/Ns) of Rolls-Royce plc (RR) RB211-Trent 768-60, 772- 60, and 772B-60 turbofan... use any of the RB211-Trent 768-60, 772-60, and 772B-60 turbofan engines listed by S/N in this AD...

  20. Application of Kingview and PLC in friction durability test system

    Science.gov (United States)

    Gao, Yinhan; Cui, Jing; Yang, Kaiyu; Ke, Hui; Song, Bing

    2013-01-01

    Using PLC and Kingview software, a friction durability test system is designed. The overall program, hardware configuration, software structure and monitoring interface are described in detail. PLC ensures the stability of data acquisition, and the KingView software makes the HMI easy to manipulate. The practical application shows that the proposed system is cheap, economical and highly reliable.

  1. 76 FR 65136 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    Science.gov (United States)

    2011-10-20

    ... Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines AGENCY: Federal Aviation Administration (FAA... information identified in this AD, contact Rolls-Royce plc, Corporate Communications, P.O. Box 31, Derby... 8, 2011, to perform the inspection. Costs of Compliance Based on the service information, we...

  2. 78 FR 54149 - Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines

    Science.gov (United States)

    2013-09-03

    ... Airworthiness Directives; Rolls-Royce plc (RR) Turbofan Engines AGENCY: Federal Aviation Administration (FAA... service information identified in this AD, contact Rolls-Royce plc, Corporate Communications, P.O. Box 31... per hour. Replacement parts are estimated to cost about $2,271 per engine. Based on these figures, we...

  3. Normal and pathological NMR imaging aspects of the posterolateral corner (PLC) of the knee

    International Nuclear Information System (INIS)

    Tardieu, M.; Lazennec, J.Y.; Christel, P.; Brasseur, J.L.; Roger, B.; Grenier, P.

    1995-01-01

    The purpose of the study is to compare normal PLC (limits lateral condyle anterior sub luxation) anatomy and its magnetic resonance imaging (MRI) appearance, with the various lesions observed in MRI, from the simple popliteus tendinous contusion to the complete PLC rupture. For this specific work on PLC lesions, we selected 61 examinations among the traumatic knees explored during the last 3 years. Surgical correlation is obtained for the 61 patients. MRI examinations are performed on a 0.5 T. unit. Normal PLC anatomy is compared to the dissection of 4 anatomic subjects. Normal MRI slices are evaluated with this reference analysis. The principle anatomical structures of the PLC include the lateral collateral ligament, the popliteus tendon, the arcuate ligament, the fabello fibular ligament, the posterolateral condylar capsule, and the posterior horn of the lateral meniscus. Surgical findings confirm PLC lesion for 58 patients with 3 false positive. Diagnosis of these lesions is important because chronical posterolateral laxity is secondary to the destabilization of lateral condyle. Unrecognized and untreated posterolateral instability may result in failure of ACL (limits lateral condyle posterior sub-luxation) reconstruction. When clinical tests are doubtful or complex, or the examination very painful, MRI evaluates completely the traumatic knee and particularly the PLC. (authors). 3 refs., 26 figs

  4. Fc gamma receptor activation induces the tyrosine phosphorylation of both phospholipase C (PLC)-gamma 1 and PLC-gamma 2 in natural killer cells

    OpenAIRE

    1992-01-01

    Crosslinking of the low affinity immunoglobulin G (IgG) Fc receptor (Fc gamma R type III) on natural killer (NK) cells initiates antibody- dependent cellular cytotoxicity. During this process, Fc gamma R stimulation results in the rapid activation of phospholipase C (PLC), which hydrolyzes membrane phosphoinositides, generating inositol-1,4,5- trisphosphate and sn-1,2-diacylglycerol as second messengers. We have recently reported that PLC activation after Fc gamma R stimulation can be inhibit...

  5. Design and implementation of tutorials for PLC B&R Automation

    OpenAIRE

    Sýkora, Daniel

    2014-01-01

    Tato bakalářská práce se zabývá návrhem a realizací úloh pro PLC B&R a podrobným návodem práce v Automation Studio. Obsahuje také informace o firmě B&R Automation Ges. m. b. H. a jejích produktech. Návrh úloh probíhal ve vývojovém prostředí B&R Automation Studio. Praktická úloha na regulaci teploty byla řešena a odzkoušena na B&R PLC X20. This bachelor’s thesis deals with the design and the implementation tutorials for PLC B&R as well as the detailed instructions of work in the Automation ...

  6. Application of PLC to mine hoist

    International Nuclear Information System (INIS)

    Zheng Liquan

    2003-01-01

    This paper describes the reform of the hoister JMK 1.85 x 4 (B) with programmable logic controller (PLC), introduces hardware architecture, software architecture and interference protection measures, and presents the existential problems and suggestions for improvement

  7. Substrate analysis of the Pneumocystis carinii protein kinases PcCbk1 and PcSte20 using yeast proteome microarrays provides a novel method for Pneumocystis signalling biology.

    Science.gov (United States)

    Kottom, Theodore J; Limper, Andrew H

    2011-10-01

    Pneumocystis carinii (Pc) undergoes morphological transitions between cysts and trophic forms. We have previously described two Pc serine/threonine kinases, termed PcCbk1 and PcSte20, with PcSte20 belonging to a family of kinases involved in yeast mating, while PcCbk1 is a member of a group of protein kinases involved in regulation of cell cycle, shape, and proliferation. As Pc remains genetically intractable, knowledge on specific substrates phosphorylated by these kinases remains limited. Utilizing the phylogenetic relatedness of Pc to Saccharomyces cerevisiae, we interrogated a yeast proteome microarray containing >4000 purified protein based peptides, leading to the identification of 18 potential PcCbk1 and 15 PcSte20 substrates (Z-score > 3.0). A number of these potential protein substrates are involved in bud site selection, polarized growth, and response to mating α factor and pseudohyphal and invasive growth. Full-length open reading frames suggested by the PcCbk1 and PcSte20 protoarrays were amplified and expressed. These five proteins were used as substrates for PcCbk1 or PcSte20, with each being highly phosphorylated by the respective kinase. Finally, to demonstrate the utility of this method to identify novel PcCbk1 and PcSte20 substrates, we analysed DNA sequence data from the partially complete Pc genome database and detected partial sequence information of potential PcCbk1 kinase substrates PcPxl1 and PcInt1. We additionally identified the potential PcSte20 kinase substrate PcBdf2. Full-length Pc substrates were cloned and expressed in yeast, and shown to be phosphorylated by the respective Pc kinases. In conclusion, the yeast protein microarray represents a novel crossover technique for identifying unique potential Pc kinase substrates. Copyright © 2011 John Wiley & Sons, Ltd.

  8. Voltage Control System of A DC Generator Using PLC

    OpenAIRE

    Subrata CHATTOPADHYAY; Sagarika PAL

    2008-01-01

    The voltage control system of a DC generator may suffer from high frequency oscillations without offset or low frequency oscillation with offset. A PID controller can eliminate both these errors. In the present paper, the voltage control system of a DC generator using a PLC based PID controller has been designed. Operation of PLC as a continuous controller has been described and the load characteristic of DC generator with and without controller have been determined experimentally and reporte...

  9. Intelligent Traffic Light Based on PLC Control

    Science.gov (United States)

    Mei, Lin; Zhang, Lijian; Wang, Lingling

    2017-11-01

    The traditional traffic light system with a fixed control mode and single control function is contradicted with the current traffic section. The traditional one has been unable to meet the functional requirements of the existing flexible traffic control system. This paper research and develop an intelligent traffic light called PLC control system. It uses PLC as control core, using a sensor module for receiving real-time information of vehicles, traffic control mode for information to select the traffic lights. Of which control mode is flexible and changeable, and it also set the countdown reminder to improve the effectiveness of traffic lights, which can realize the goal of intelligent traffic diversion, intelligent traffic diversion.

  10. A formal safety analysis for PLC software-based safety critical system using Z

    International Nuclear Information System (INIS)

    Koh, Jung Soo

    1997-02-01

    This paper describes a formal safety analysis technique which is demonstrated by performing empirical formal safety analysis with the case study of beamline hutch door Interlock system that is developed by using PLC (Programmable Logic Controller) systems at the Pohang Accelerator Laboratory. In order to perform formal safety analysis, we have built the Z formal specifications representation from user requirement written in ambiguous natural language and target PLC ladder logic, respectively. We have also studied the effective method to express typical PLC timer component by using specific Z formal notation which is supported by temporal history. We present a formal proof technique specifying and verifying that the hazardous states are not introduced into ladder logic in the PLC-based safety critical system. And also, we have found that some errors or mismatches in user requirement and final implemented PLC ladder logic while analyzing the process of the consistency and completeness of Z translated formal specifications. In the case of relatively small systems like Beamline hutch door interlock system, a formal safety analysis including explicit proof is highly recommended so that the safety of PLC-based critical system may be enhanced and guaranteed. It also provides a helpful benefits enough to comprehend user requirement expressed by ambiguous natural language

  11. Upgradation in SCADA and PLC of existing LN{sub 2} control system for SST-1

    Energy Technology Data Exchange (ETDEWEB)

    Panchal, Pradip, E-mail: pradip@ipr.res.in; Mahesuria, Gaurang; Panchal, Rohit; Patel, Rakesh; Sonara, Dashrath; Pitroda, Dipen; Nimavat, Hiren; Tanna, Vipul; Pradhan, Subrata

    2016-11-15

    Highlights: • The control system of LN{sub 2} Management System of SST-1 is designed on PLC and SCADA. • The implementation and results of up-gradation in PLC and SCADA are reported. • The up-gradation in PLC and SCADA has improved the reliability & availability of SST-1 LN{sub 2} system. - Abstract: Helium Refrigerator/Liquefier system of Steady State Superconducting Tokamak (SST-1) incorporates Liquid Nitrogen (LN{sub 2}) pre-cooling system. LN{sub 2} is used for 80 K thermal shields of SST-1, current feeder system and integrated flow distribution and control system. The LN{sub 2} management system is distributed system and requires automatic control. Initially LN{sub 2} control system had Citect based Supervisory Control and Data Acquisition (SCADA) and Koyo make Programmable Logic Controller (PLC). With the passage of time and due to unavailability of their hardware, it is being obsoleted. So, the requirements of new PLC and SCADA systems have been envisaged to make uninterruptable operation of SST-1 cryogenic system. Therefore, Wonderware SCADA and Schneider Electric make PLC is programmed to replace Citect SCADA and Koyo PLC. New control features have been added in upgraded control system for better management of LN{sub 2} system. This upgradation of SCADA and PLC is completed, tested successfully and in operation. Operational performance highlights of the new upgraded system are presented in this paper.

  12. Model-based automated testing of critical PLC programs.

    CERN Document Server

    Fernández Adiego, B; Tournier, J-C; González Suárez, V M; Bliudze, S

    2014-01-01

    Testing of critical PLC (Programmable Logic Controller) programs remains a challenging task for control system engineers as it can rarely be automated. This paper proposes a model based approach which uses the BIP (Behavior, Interactions and Priorities) framework to perform automated testing of PLC programs developed with the UNICOS (UNified Industrial COntrol System) framework. This paper defines the translation procedure and rules from UNICOS to BIP which can be fully automated in order to hide the complexity of the underlying model from the control engineers. The approach is illustrated and validated through the study of a water treatment process.

  13. A formal safety analysis for PLC software-based safety critical system using Z

    International Nuclear Information System (INIS)

    Koh, Jung Soo; Seong, Poong Hyun

    1997-01-01

    This paper describes a formal safety analysis technique which is demonstrated by performing empirical formal safety analysis with the case study of beamline hutch door Interlock system that is developed by using PLC (Programmable Logic Controller) systems at the Pohang Accelerator Laboratory. In order to perform formed safety analysis, we have built the Z formal specifications representation from user requirement written in ambiguous natural language and target PLC ladder logic, respectively. We have also studied the effective method to express typical PLC timer component by using specific Z formal notation which is supported by temporal history. We present a formal proof technique specifying and verifying that the hazardous states are not introduced into ladder logic in the PLC-based safety critical system

  14. MultiController: the PLC-SCADA object for advanced regulation

    CERN Document Server

    Ortola, J

    2007-01-01

    Nowadays, industrial solutions with PLCs (Programmable Logic Controllers) have basic control loop features. The SCADA (Supervisory Control And Data Acquisition) system is a key point of the process control system due to an efficient HMI (Human Machine Interfaces) that provides an open method of tuning and leading possibilities. As a consequence, advanced control algorithms have to be developed and implemented for those PLC-SCADA solutions in order to provide perspectives in solving complex and critical regulation problems. The MultiController is an object integrated for a large scale project at CERN (the European Organization for Nuclear Research) named LHC-GCS (Large Hadron Collider - Gas Control System). It is developed for a Framework called CERN-UNICOS based on PLC-SCADA facilities. The MultiController object offers various advanced control loop strategies. It gives to the user advanced control algorithms like PID, Smith Predictor, PFC, GPC and RST. It is implemented as a monolithic entity (in PLC and SCA...

  15. Separation of integrin-dependent adhesion from morphological changes based on differential PLC specificities.

    Science.gov (United States)

    Wooten, D K; Teague, T K; McIntyre, B W

    1999-01-01

    In normal lymphocytes an inside-out signal up-regulating integrin adhesion is followed by a ligand-mediated outside-in cell spreading signal. Protein kinase C (PKC) inhibition blocks lymphocyte adherence to and spreading on fibronectin. In contrast, putative PLC inhibitors yield distinct differences with respect to adhesion and morphology. The phosphatidylinositol-specific phospholipase C (PLC) inhibitor neomycin blocked spreading of CD3/CD28-activated T cells on fibronectin by disrupting adhesion. Furthermore, when an additional inside-out signal for fibronectin adhesion is unnecessary such as with HPB-ALL T leukemic or phorbol-myristate-acetate-treated normal T cells, neomycin treatment does not alter adhesion or morphology. However, the phosphatidylcholine-specific PLC inhibitor D609 abrogates cell spreading without affecting adhesion to fibronectin in these cells as well as the CD3/CD28-activated T cells. These results strongly suggest that inside-out signaling for the integrin alpha4beta1 in lymphocytes proceeds through phosphatidylinositol-specific PLC and PKC, whereas the outside-in signal utilizes phosphatidylcholine-specific PLC and PKC.

  16. Voltage Control System of A DC Generator Using PLC

    Directory of Open Access Journals (Sweden)

    Subrata CHATTOPADHYAY

    2008-06-01

    Full Text Available The voltage control system of a DC generator may suffer from high frequency oscillations without offset or low frequency oscillation with offset. A PID controller can eliminate both these errors. In the present paper, the voltage control system of a DC generator using a PLC based PID controller has been designed. Operation of PLC as a continuous controller has been described and the load characteristic of DC generator with and without controller have been determined experimentally and reported in this paper.

  17. Transforming PLC Programs into Formal Models for Verification Purposes

    CERN Document Server

    Darvas, D; Blanco, E

    2013-01-01

    Most of CERN’s industrial installations rely on PLC-based (Programmable Logic Controller) control systems developed using the UNICOS framework. This framework contains common, reusable program modules and their correctness is a high priority. Testing is already applied to find errors, but this method has limitations. In this work an approach is proposed to transform automatically PLC programs into formal models, with the goal of applying formal verification to ensure their correctness. We target model checking which is a precise, mathematical-based method to check formalized requirements automatically against the system.

  18. Performance analysis of the PLC (Power Line Communication) in medium voltage electrical networks; Analise de desempenho de sistemas PLC em redes eletricas de media tensao

    Energy Technology Data Exchange (ETDEWEB)

    Mota, A.A.; Paleta, R. [Pontificia Universidade Catolica de Campinas (PUC-Campinas), SP (Brazil)], E-mail: amota@puc-campinas.edu.br; Mota, L.T.M.; Ricardo, R.A. [Indelmatec Engenharia, Campinas, SP (Brazil)], E-mail: mota@indelmatec.com.br

    2009-07-01

    Nowadays, the information access in communication networks is widely explored due to the increase of Internet users. In this context, the PLC (Power Line Communication) technology is an alternative for data transmission. This technology is based on the usage of transmission/distribution power lines for data transmission. However there are some problems related to the usage of this technology: adequate data transmission rates and generation of acceptable levels of electromagnetic interference (EMI). This work had the objective of studying the performance of PLC systems in medium voltage electrical networks, through the assess of data transmission rates and the generated EMI. Tests were carried out in a test field that corresponded to a medium voltage electrical network and the obtained results show that, under some circumstances, the PLC system does not reach the existent technical recommendations. (author)

  19. ORPLOT.PC: a graphic utility for ORMGEN.PC and ORVIRT.PC

    International Nuclear Information System (INIS)

    Inversini, C.; Bryson, J.W.

    1986-06-01

    ORPLOT.PC is an interactive graphic utility for ORMGEN.PC and ORVIRT.PC. It executes on an IBM PC/XT or PC/AT equipped with hard disk, graphic card, and 512K minimum memory. The program is capable of: (1) displaying finite-element meshes generated by ORMGEN.PC complete with node numbers, element numbers, and boundary conditions; and (2) generating deformed mesh plots, contour plots, line (X-Y) plots, and developed surface plots of ORVIRT.PC output. A zooming feature allows detailed inspection of any subregion. Because simplicity and ease of use were important objectives during program development, all commands are entered interactively using free format. The option of automatic or user-defined scaling for most plots is another convenience. Plot files may be created and written to hard disk for subsequent hardcopy to printer or plotter. 2 refs., 7 figs

  20. File list: Pol.Plc.50.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.50.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.50.RNA_polymerase_II.AllCell.bed ...

  1. File list: Pol.Plc.10.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.10.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.10.RNA_polymerase_II.AllCell.bed ...

  2. File list: Pol.Plc.05.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.05.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.05.RNA_polymerase_II.AllCell.bed ...

  3. File list: Pol.Plc.20.RNA_polymerase_II.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.20.RNA_polymerase_II.AllCell hg19 RNA polymerase RNA polymerase II Placenta... http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.20.RNA_polymerase_II.AllCell.bed ...

  4. File list: Pol.Plc.50.RNA_Polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.50.RNA_Polymerase_III.AllCell mm9 RNA polymerase RNA Polymerase III Placent...a http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/Pol.Plc.50.RNA_Polymerase_III.AllCell.bed ...

  5. File list: Pol.Plc.20.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.20.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.20.RNA_polymerase_III.AllCell.bed ...

  6. File list: Pol.Plc.10.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.10.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.10.RNA_polymerase_III.AllCell.bed ...

  7. File list: Pol.Plc.05.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.05.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.05.RNA_polymerase_III.AllCell.bed ...

  8. File list: Pol.Plc.50.RNA_polymerase_III.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available Pol.Plc.50.RNA_polymerase_III.AllCell hg19 RNA polymerase RNA polymerase III Placen...ta http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/Pol.Plc.50.RNA_polymerase_III.AllCell.bed ...

  9. 75 FR 46864 - Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes

    Science.gov (United States)

    2010-08-04

    ...-0225; Directorate Identifier 2009-NM-203-AD] RIN 2120-AA64 Airworthiness Directives; Short Brothers PLC... this proposed AD, contact Short Brothers PLC, Airworthiness, P.O. Box 241, Airport Road, Belfast, BT3... amend this proposed AD based on those comments. We will post all comments we receive, without change, to...

  10. Fifth Baltic Sea pollution load compilation (PLC-5)

    Energy Technology Data Exchange (ETDEWEB)

    Knuuttila, S.; Svendsen, L. M.; Staaf, H.; Kotilainen, P.; Boutrup, S.; Pyhala, M.; Durkin, M.

    2011-07-01

    This report includes the main results from the Fifth Pollution Load Compilation abbreviated PLC-5. It includes quantified annual waterborne total loads (from rivers, unmonitored and coastal areas as well as direct point and diffuse sources discharging directly to the Baltic Sea) from 1994 to 2008 to provide a basis for evaluating any decreasing (or increasing) trends in the total waterborne inputs to the Baltic Sea. Chapter 1 contains the objectives of PLC and the framework on classification of inputs and sources. Chapter 2 includes a short description of the Baltic Sea catchment area, while the methods for quantification and analysis together with quality assurance topics are briefly introduced in Chapter 3. More detailed information on methodologies is presented in the PLC-5 guidelines (HELCOM 2006). Chapter 4 reports the total inputs to the Baltic Sea of nutrients and selected heavy metals. Furthermore, the results of the quatification of discharges and losses of nitrogen and phosphorus from point and diffuse sources into inland surface waters within the Baltic Sea catchment area (source-oriented approach or gross loads) as well as the total load to the maritime area (load-oriented approarch or net loads) in 2006 are shown. Typically, results are presented by country and by main Baltic Sea sub-region. In Chapter 5, flow normalization is introduced and the results of trend analyses on 1994-2008 time series data on total waterborne loads of nitrogen and phosphorus are given together with a first evaluation of progress in obtaining the provisional reduction targets by country and by main Baltic Sea sub-region. Chapter 6 includes discussion of some of the main conclusions and advice for future PLCs. The annexes contain the flow-normalized annual load data and figures and tables with results from the PLC-5.

  11. PLC and DTAM Software Programs for Pumping Instrumentation and Control Skid N

    International Nuclear Information System (INIS)

    KOCH, M.R.

    2000-01-01

    This document describe the software programs for the Programmable Logic Controller and the Datable Access Module for Pumping Instrumentation and Control skid ''N''. The Appendices contains copies of the printouts of these software programs. This document describes the software programs for the Allen-Bradley SLC 500 programmable logic controller (PLC) and the Allen-Bradley DTAM PLUS operator interface module used on Pumping Instrumentation and Control (PIC) skid ''N''. The software programs for the SLC 500 and DTAM Plus are based on the core programs provided by Allen-Bradley. The PLC and DTAM software programs on skid ''D'' for SX-104 are the baseline programs. These baselines have been tailored for U-farm skids. The skid ''N'' program for U-109 is similar to the skid ''M'' program for U-102. An Acceptance Test Procedure (ATP) and an Operational Test Procedure (OTP) verify that the software programs meet the specific requirements for U-109 pumping. This document represents the final PLC and DTAM programs for PIC skid ''N'' at U-109. These programs were printed out after the performance of the OTP. The OTP acts as the final qualification test for the software programs. Functional requirements and details of the PLC ladder logic are described in this document. The final programs entered into the PLC and DTAM Plus are included as Appendices to this document

  12. File list: InP.Plc.50.Input_control.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Plc.50.Input_control.AllCell hg19 Input control Input control Placenta SRX19004...9,SRX080366 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Plc.50.Input_control.AllCell.bed ...

  13. File list: InP.Plc.05.Input_control.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Plc.05.Input_control.AllCell hg19 Input control Input control Placenta SRX19004...9,SRX080366 http://dbarchive.biosciencedbc.jp/kyushu-u/hg19/assembled/InP.Plc.05.Input_control.AllCell.bed ...

  14. Integration of the HVCM PLC into the PEFP Control System

    International Nuclear Information System (INIS)

    Song, Young Gi; Jang, Ji Ho; Kwon, Hyeok Jung; Cho, Yong Sub

    2011-01-01

    The High Voltage Converter Modulators (HVCM) for the 100-MeV accelerator was installed to drive the 20-MeV linac. There are two klystrons in the 20-MeV linac and one modulator was used to drive two klystrons simultaneously. The HVCM for the 20-MeV linac area in Korea Atomic Energy Research Institute (KAERI) is shown in Fig. 1. We were faced with the necessity of integrating Programmable Logic Controllers (PLCs) for the HVCM into the Proton Engineering Frontier Project (PEFP) control system. At the PEFP, Experimental Physics and Industrial Control System (EPICS) has become the most widely used solution for building control systems for 100MeV proton accelerator. The EPICS as a standard development tool is a distributed architecture that provides several solutions such as independent programming tools for operating system, operator interface tools, and archiving tools. Although EPICS is used directly in our control system, HVCMs were delivered with the Allen-Bradley ControlLogix as a PLC. The industrial PLC has been verified for safety systems. We need to connect an interface from our EPICS control system to AB-PLC using Ethernet/IP (ControlNet over Ethernet) protocol over Ethernet. In this paper, we will present the communication protocol and EPICS IOC installation for the EPICS based PLC control system

  15. PLC-controlled cryostats for the BlackGEM and MeerLICHT detectors

    Science.gov (United States)

    Raskin, Gert; Morren, Johan; Pessemier, Wim; Bloemen, Steven; Klein-Wolt, Marc; Roelfsema, Ronald; Groot, Paul; Aerts, Conny

    2016-08-01

    BlackGEM is an array of telescopes, currently under development at the Radboud University Nijmegen and at NOVA (Netherlands Research School for Astronomy). It targets the detection of the optical counterparts of gravitational waves. The first three BlackGEM telescopes are planned to be installed in 2018 at the La Silla observatory (Chile). A single prototype telescope, named MeerLICHT, will already be commissioned early 2017 in Sutherland (South Africa) to provide an optical complement for the MeerKAT radio array. The BlackGEM array consists of, initially, a set of three robotic 65-cm wide-field telescopes. Each telescope is equipped with a single STA1600 CCD detector with 10.5k x 10.5k 9-micron pixels that covers a 2.7 square degrees field of view. The cryostats for housing these detectors are developed and built at the KU Leuven University (Belgium). The operational model of BlackGEM requires long periods of reliable hands-off operation. Therefore, we designed the cryostats for long vacuum hold time and we make use of a closed-cycle cooling system, based on Polycold PCC Joule-Thomson coolers. A single programmable logic controller (PLC) controls the cryogenic systems of several BlackGEM telescopes simultaneously, resulting in a highly reliable, cost-efficient and maintenance-friendly system. PLC-based cryostat control offers some distinct advantages, especially for a robotic facility. Apart of temperature monitoring and control, the PLC also monitors the vacuum quality, the power supply and the status of the PCC coolers (compressor power consumption and temperature, pressure in the gas lines, etc.). Furthermore, it provides an alarming system and safe and reproducible procedures for automatic cool down and warm up. The communication between PLC and higher-level software takes place via the OPC-UA protocol, offering a simple to implement, yet very powerful interface. Finally, a touch-panel display on the PLC provides the operator with a user-friendly and robust

  16. Realization of PLC to the Variable Frequency Speed Regulation System of Mine Local Ventilator based on RS-485 Communication

    Science.gov (United States)

    Ma, Kai; Li, Jian; Yun, Yichong

    2018-03-01

    The article first introduces the merits of serial communication in the PLC to the variable frequency speed regulation system of mine local ventilator, and then sets up a hardware application development platform of PLC and inverter based on RS-485 communication technology, next presents communication initialization of the PLC and Inverter. Finally according to the control requirements, PLC send run operation & monitoring instruction to Inverter, realizes the serial communication control between the PLC and Inverter.

  17. Automated Translation of Safety Critical Application Software Specifications into PLC Ladder Logic

    Science.gov (United States)

    Leucht, Kurt W.; Semmel, Glenn S.

    2008-01-01

    The numerous benefits of automatic application code generation are widely accepted within the software engineering community. A few of these benefits include raising the abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at the NASA Kennedy Space Center (KSC) recognized the need for PLC code generation while developing their new ground checkout and launch processing system. They developed a process and a prototype software tool that automatically translates a high-level representation or specification of safety critical application software into ladder logic that executes on a PLC. This process and tool are expected to increase the reliability of the PLC code over that which is written manually, and may even lower life-cycle costs and shorten the development schedule of the new control system at KSC. This paper examines the problem domain and discusses the process and software tool that were prototyped by the KSC software engineers.

  18. Prototype of Automated PLC Model Checking Using Continuous Integration Tools

    CERN Document Server

    Lettrich, Michael

    2015-01-01

    To deal with the complexity of operating and supervising large scale industrial installations at CERN, often Programmable Logic Controllers (PLCs) are used. A failure in these control systems can cause a disaster in terms of economic loses, environmental damages or human losses. Therefore the requirements to software quality are very high. To provide PLC developers with a way to verify proper functionality against requirements, a Java tool named PLCverif has been developed which encapsulates and thus simplifies the use of third party model checkers. One of our goals in this project is to integrate PLCverif in development process of PLC programs. When the developer changes the program, all the requirements should be verified again, as a change on the code can produce collateral effects and violate one or more requirements. For that reason, PLCverif has been extended to work with Jenkins CI in order to trigger automatically the verication cases when the developer changes the PLC program. This prototype has been...

  19. Phosphatidylcholine-specific phospholipase C inhibition down- regulates CXCR4 expression and interferes with proliferation, invasion and glycolysis in glioma cells.

    Directory of Open Access Journals (Sweden)

    Laura Mercurio

    Full Text Available The chemokine receptor CXCR4 plays a crucial role in tumors, including glioblastoma multiforme (GBM, the most aggressive glioma. Phosphatidylcholine-specific phospholipase C (PC-PLC, a catabolic enzyme of PC metabolism, is involved in several aspects of cancer biology and its inhibition down-modulates the expression of growth factor membrane receptors interfering with their signaling pathways. In the present work we investigated the possible interplay between CXCR4 and PC-PLC in GBM cells.Confocal microscopy, immunoprecipitation, western blot analyses, and the evaluation of migration and invasion potential were performed on U87MG cells after PC-PLC inhibition with the xanthate D609. The intracellular metabolome was investigated by magnetic resonance spectroscopy; lactate levels and lactate dehydrogenase (LDH activity were analyzed by colorimetric assay.Our studies demonstrated that CXCR4 and PC-PLC co-localize and are associated on U87MG cell membrane. D609 reduced CXCR4 expression, cell proliferation and invasion, interfering with AKT and EGFR activation and expression. Metabolic analyses showed a decrease in intracellular lactate concentration together with a decrement in LDH activity.Our data suggest that inhibition of PC-PLC could represent a new molecular approach in glioma biology not only for its ability in modulating cell metabolism, glioma growth and motility, but also for its inhibitory effect on crucial molecules involved in cancer progression.

  20. Intergenerational Justice Perceptions and the Role of Welfare Regimes

    DEFF Research Database (Denmark)

    Sabbagh, Clara; Vanhuysse, Pieter

    2010-01-01

    , different welfare regimes structure young people's perceptions of the justness of public resources transfers from young to elderly age-groups and (2) the perceived relative contributions and rewards of various age-groups. Thus we inquire about both the perceived support in principle and about the perceived...... justness of actual outcomes of resource transfers between age-groups. We find that support of transfers from the young to the old is higher in social-democratic and conservative welfare regimes than in liberal and radical regimes. Support of resource transfers also correlates positively with a 'welfare......-statist' ideological frame (the endorsement of egalitarian redistribution and broad state responsibility for welfare provision and the attribution of social inequality to external causes), and negatively with a 'market-based' frame (individualism, a work ethic, and internal attribution). Regarding actual outcomes...

  1. Evaluation of PLC Channel Capacity and ABER Performances for OFDM-Based Two-Hop Relaying Transmission

    Directory of Open Access Journals (Sweden)

    Sana Ezzine

    2017-01-01

    Full Text Available Powerline network is recognized as a favorable infrastructure for Smart Grid to transmit information in the network thanks to its broad coverage and low cost deployment. The existing works are trying to improve and adapt transmission techniques to reduce Powerline Communication (PLC channel attenuation and exploit the limited bandwidth to support high data rate over long distances. Two-hop relaying BroadBand PLC (BB-PLC system, in which Orthogonal Frequency Division Multiplexing (OFDM is used, is considered in this paper. We derive and compare the PLC channel capacity and the end-to-end Average BER (ABER for OFDM-based direct link (DL BB-PLC system and for OFDM-based two-hop relaying BB-PLC system for Amplify and Forward (AF and Decode and Forward (DF protocols. We analyze the improvements when we consider the direct link in a cooperative communication when the relay node only transmits the correctly decoded signal. Maximum ratio combining is employed at the destination node to detect the transmitted signal. In addition, in this paper, we highlight the impact of the relay location on the channel capacity and ABER for AF and DF transmission protocols. Moreover, an efficient use of the direct link was also investigated in this paper.

  2. Bit rate maximization for multicast LP-OFDM systems in PLC context

    OpenAIRE

    Maiga , Ali; Baudais , Jean-Yves; Hélard , Jean-François

    2009-01-01

    ISBN: 978-88-900984-8-2.; International audience; In this paper, we propose a new resource allocation algorithm based on linear precoding technique for multicast OFDM systems. Linear precoding technique applied to OFDM systems has already proved its ability to significantly increase the system throughput in a powerline communication (PLC) context. Simulations through PLC channels show that this algorithm outperforms the classical multicast method (up to 7.3% bit rate gain) and gives better pe...

  3. 76 FR 80430 - Rio Tinto plc and Rio Tinto Limited; Notice of Application

    Science.gov (United States)

    2011-12-23

    ... plc and Rio Tinto Limited; Notice of Application December 19, 2011. AGENCY: Securities and Exchange Commission (``Commission''). ACTION: Notice of application under section 3(b)(2) and 45(a) of the Investment Company Act of 1940 (the ``Act''). SUMMARY: Summary of Application: Rio Tinto plc (``RTP'') and Rio Tinto...

  4. Evaluation of PLC Channel Capacity and ABER Performances for OFDM-Based Two-Hop Relaying Transmission

    OpenAIRE

    Ezzine, Sana; Abdelkefi, Fatma; Cances, Jean Pierre; Meghdadi, Vahid; Bouallégue, Ammar

    2017-01-01

    Powerline network is recognized as a favorable infrastructure for Smart Grid to transmit information in the network thanks to its broad coverage and low cost deployment. The existing works are trying to improve and adapt transmission techniques to reduce Powerline Communication (PLC) channel attenuation and exploit the limited bandwidth to support high data rate over long distances. Two-hop relaying BroadBand PLC (BB-PLC) system, in which Orthogonal Frequency Division Multiplexing (OFDM) is u...

  5. Connecting programmable logic controllers (PLC) to control and data acquisition a comparison of the JET and Wendelstein 7-X approach

    International Nuclear Information System (INIS)

    Hennig, Christine; Kneupner, Klaus; Kinna, David

    2012-01-01

    Highlights: ► We describe 2 ways connecting PLCs to fusion control and data acquisition software. ► At W7-X standardization of the PLC type eases the maintenance of the software. ► At JET PLCs are interfaced with a daemon that hides the PLC specific part. ► There is potential to unify the approaches towards a common fusion PLC interface. - Abstract: The use of programmable logic controllers (PLC) for automation of electromechanical processes is an industrial control system technology. It is more and more in use within the fusion community. Traditionally PLC based systems are operated and maintained using proprietary SCADA systems (supervisory control and data acquisition). They are hardly ever integrated with the fusion control and data acquisition systems. An overview of the state of the art in fusion is given in the article. At JET an inhouse “black box protocol” approach has been developed to communicate with any external system via a dedicated http based protocol. However, a PLC usually cannot be modified to implement this special protocol. Hence, a software layer has been developed that interfaces a PLC by implementing the PLC specific communication part on one side and the black box protocol part on the other side. The software is completely data driven i.e. editing the data structure changes the logic accordingly. It can be tested using the web capability of the black box protocol. Multiple PLC types from different vendors are supported, thus multiple protocols to interface the PLC are in use. Depending on the PLC type and available tools it can be necessary to program the PLC accordingly. Wendelstein 7-X uses another approach. For every single PLC a dedicated communication from and to CoDaC is implemented. This communication is projected (programmed) in the PLC and configurable (data driven) on the CoDaC side. The protocol is UDP based and observed via timeout mechanisms. The use of PLCs for Wendelstein 7-X is standardized. Therefore a single

  6. Connecting programmable logic controllers (PLC) to control and data acquisition a comparison of the JET and Wendelstein 7-X approach

    Energy Technology Data Exchange (ETDEWEB)

    Hennig, Christine, E-mail: Christine.Hennig@ipp.mpg.de [Max-Planck-Institut fuer Plasmaphysik, Wendelsteinstrasse 1, 17491 Greifswald (Germany); Kneupner, Klaus; Kinna, David [JET-EFDA, Culham Science Centre, OX14 3DB Abingdon (United Kingdom)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer We describe 2 ways connecting PLCs to fusion control and data acquisition software. Black-Right-Pointing-Pointer At W7-X standardization of the PLC type eases the maintenance of the software. Black-Right-Pointing-Pointer At JET PLCs are interfaced with a daemon that hides the PLC specific part. Black-Right-Pointing-Pointer There is potential to unify the approaches towards a common fusion PLC interface. - Abstract: The use of programmable logic controllers (PLC) for automation of electromechanical processes is an industrial control system technology. It is more and more in use within the fusion community. Traditionally PLC based systems are operated and maintained using proprietary SCADA systems (supervisory control and data acquisition). They are hardly ever integrated with the fusion control and data acquisition systems. An overview of the state of the art in fusion is given in the article. At JET an inhouse 'black box protocol' approach has been developed to communicate with any external system via a dedicated http based protocol. However, a PLC usually cannot be modified to implement this special protocol. Hence, a software layer has been developed that interfaces a PLC by implementing the PLC specific communication part on one side and the black box protocol part on the other side. The software is completely data driven i.e. editing the data structure changes the logic accordingly. It can be tested using the web capability of the black box protocol. Multiple PLC types from different vendors are supported, thus multiple protocols to interface the PLC are in use. Depending on the PLC type and available tools it can be necessary to program the PLC accordingly. Wendelstein 7-X uses another approach. For every single PLC a dedicated communication from and to CoDaC is implemented. This communication is projected (programmed) in the PLC and configurable (data driven) on the CoDaC side. The protocol is UDP based and

  7. Multi-satellite study of the excitation of Pc3 and Pc4-5 ULF waves and their penetration across the plasmapause during the 2003 Halloween superstorm

    Science.gov (United States)

    Balasis, G.; Daglis, I. A.; Mann, I. R.; Papadimitriou, C.; Zesta, E.; Georgiou, M.; Haagmans, R.; Tsinganos, K.

    2015-10-01

    We use multi-satellite and ground-based magnetic data to investigate the concurrent characteristics of Pc3 (22-100 mHz) and Pc4-5 (1-22 mHz) ultra-low-frequency (ULF) waves on the 31 October 2003 during the Halloween magnetic superstorm. ULF waves are seen in the Earth's magnetosphere, topside ionosphere, and Earth's surface, enabling an examination of their propagation characteristics. We employ a time-frequency analysis technique and examine data from when the Cluster and CHAMP spacecraft were in good local time (LT) conjunction near the dayside noon-midnight meridian. We find clear evidence of the excitation of both Pc3 and Pc4-5 waves, but more significantly we find a clear separation in the L shell of occurrence of the Pc4-5 and Pc3 waves in the equatorial inner magnetosphere, separated by the density gradients at the plasmapause boundary layer. A key finding of the wavelet spectral analysis of data collected from the Geotail, Cluster, and CHAMP spacecraft and the CARISMA and GIMA magnetometer networks was a remarkably clear transition of the waves' frequency into dominance in a higher-frequency regime within the Pc3 range. Analysis of the local field line resonance frequency suggests that the separation of the Pc4-5 and Pc3 emissions across the plasmapause is consistent with the structure of the inhomogeneous field line resonance Alfvén continuum. The Pc4-5 waves are consistent with direct excitation by the solar wind in the plasma trough, as well as Pc3 wave absorption in the plasmasphere following excitation by upstream waves originating at the bow shock in the local noon sector. However, despite good solar wind coverage, our study was not able to unambiguously identify a clear explanation for the sharp universal time (UT) onset of the discrete frequency and large-amplitude Pc3 wave power.

  8. Application of PLC timing control in the neutral beam injector of HT-7

    International Nuclear Information System (INIS)

    Song Shihua; Liu Zhimin; Liu Sheng; Hu Chundong

    2006-01-01

    HT-7 tokamak high power Neutral Beam Injector heating system runs in the mode of pulse timing-control of PLC. The thesis discusses the theory about the operation for the experiment of discharge, which is controlled by PLC logical connection and introduces excellent user-friendly operating interface and the development of the ladder application program and upper monitor program in the VB6.0 environment. Monitor the conditions of power and facility real time by the upper monitor interface. The application of PLC control system ensures the experiment facility running safely and convenient for modifying and setting the parameter simply during the course of experiment. (authors)

  9. Arbitration Award of ICSID on the Investment Disputes of Churchill Mining PLC v. Republic of Indonesia

    Directory of Open Access Journals (Sweden)

    Yordan Gunawan

    2017-03-01

    Full Text Available The research is aimed at analyzing the ICSID (International Centre Settlement Investment Dispute decision in solving a dispute between Churchill Mining PLC and the Government of the Republic of Indonesia. The case brought to the public attention, because mining license owned by PT. Ridlatama which acquired from Churchill Mining PLC had been revocated. Churchill Mining PLC holds 75% share of PT. Ridlatama and it suffered losses caused by the revocation of its mining license. Churchill Mining PLC filed the case to the local court but it failed. Churchill Mining PLC then sought ruling from International arbitration or ICSID. On December 6, 2016, ICSID issued a decision that clearly threw out Churchill Mining PLC claim. ICSID, the World Bank court, ordered the firm to pay a total of US$.9.446.528 in cost to the Government of the Republic of Indonesia. It is based on the evidences that the UK-Australia company did the fraud and had document forgery of coal mining permit in East Kutai, Indonesia. So the firm has violated the Bilateral Investment Treaties between Indonesia-UK and Indonesia-Australia.

  10. Inhibition of phosphatidylcholine-specific phospholipase C prevents bone marrow stromal cell senescence in vitro.

    Science.gov (United States)

    Sun, Chunhui; Wang, Nan; Huang, Jie; Xin, Jie; Peng, Fen; Ren, Yinshi; Zhang, Shangli; Miao, Junying

    2009-10-01

    Bone marrow stromal cells (BMSCs) can proliferate in vitro and can be transplanted for treating many kinds of diseases. However, BMSCs become senescent with long-term culture, which inhibits their application. To understand the mechanism underlying the senescence, we investigated the activity of phosphatidylcholine-specific phospholipase C (PC-PLC) and levels of integrin beta4, caveolin-1 and ROS with BMSC senescence. The activity of PC-PLC and levels of integrin beta4, caveolin-1 and ROS increased greatly during cell senescence. Selective inhibition of increased PC-PLC activity with D609 significantly decreased the number of senescence-associated beta galactosidase positive cells in BMSCs. Furthermore, D609 restored proliferation of BMSCs and their differentiation into adipocytes. Moreover, D609 suppressed the elevated levels of integrin beta4, caveolin-1 and ROS. The data suggest that PC-PLC is involved in senescence of BMSCs, and its function is associated with integrin beta4, caveolin-1 and ROS. (c) 2009 Wiley-Liss, Inc.

  11. Plant phosphatidylcholine-hydrolyzing phospholipases C NPC3 and NPC4 with roles in root development and brassinolide signaling in Arabidopsis thaliana.

    Science.gov (United States)

    Wimalasekera, Rinukshi; Pejchar, Premysl; Holk, André; Martinec, Jan; Scherer, Günther F E

    2010-05-01

    Phosphatidylcholine-hydrolyzing phospholipase C (PC-PLC) catalyzes the hydrolysis of phosphatidylcholine (PC) to generate phosphocholine and diacylglycerol (DAG). PC-PLC has a long tradition in animal signal transduction to generate DAG as a second messenger besides the classical phosphatidylinositol splitting phospholipase C (PI-PLC). Based on amino acid sequence similarity to bacterial PC-PLC, six putative PC-PLC genes (NPC1 to NPC6) were identified in the Arabidopsis genome. RT-PCR analysis revealed overlapping expression pattern of NPC genes in root, stem, leaf, flower, and silique. In auxin-treated P(NPC3):GUS and P(NPC4):GUS seedlings, strong increase of GUS activity was visible in roots, leaves, and shoots and, to a weaker extent, in brassinolide-treated (BL) seedlings. P(NPC4):GUS seedlings also responded to cytokinin with increased GUS activity in young leaves. Compared to wild-type, T-DNA insertional knockouts npc3 and npc4 showed shorter primary roots and lower lateral root density at low BL concentrations but increased lateral root densities in response to exogenous 0.05-1.0 μM BL. BL-induced expression of TCH4 and LRX2, which are involved in cell expansion, was impaired but not impaired in repression of CPD, a BL biosynthesis gene, in BL-treated npc3 and npc4. These observations suggest NPC3 and NPC4 are important in BL-mediated signaling in root growth. When treated with 0.1 μM BL, DAG accumulation was observed in tobacco BY-2 cell cultures labeled with fluorescent PC as early as 15 min after application. We hypothesize that at least one PC-PLC is a plant signaling enzyme in BL signal transduction and, as shown earlier, in elicitor signal transduction.

  12. The PLC: a logical development

    OpenAIRE

    Walker, Mark; Bissell, Christopher; Monk, John

    2010-01-01

    Programmable Logic Controllers (PLCs) have been used to control industrial processes and equipment for over 40 years, having their first commercially recognised application in 1969. Since then there have been enormous changes in the design and application of PLCs, yet developments were evolutionary rather than radical. The flexibility of the PLC does not confine it to industrial use and it has been used for disparate non-industrial control applications . This article reviews the history, deve...

  13. File list: InP.Plc.20.Input_control.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Plc.20.Input_control.AllCell mm9 Input control Input control Placenta SRX112971...02,SRX404310,SRX1072160,SRX871507,SRX192097,SRX192098,SRX192099,SRX204148 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.20.Input_control.AllCell.bed ...

  14. File list: InP.Plc.05.Input_control.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Plc.05.Input_control.AllCell mm9 Input control Input control Placenta SRX344647...160,SRX204147,SRX404310,SRX871506,SRX871507,SRX192098,SRX192097,SRX192099 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.05.Input_control.AllCell.bed ...

  15. File list: InP.Plc.10.Input_control.AllCell [Chip-atlas[Archive

    Lifescience Database Archive (English)

    Full Text Available InP.Plc.10.Input_control.AllCell mm9 Input control Input control Placenta SRX344648...310,SRX871506,SRX142911,SRX871507,SRX204148,SRX192098,SRX192097,SRX192099 http://dbarchive.biosciencedbc.jp/kyushu-u/mm9/assembled/InP.Plc.10.Input_control.AllCell.bed ...

  16. Framing access to medicines in developing countries: an analysis of media coverage of Canada's Access to Medicines Regime.

    Science.gov (United States)

    Esmail, Laura C; Phillips, Kaye; Kuek, Victoria; Cosio, Andrea Perez; Kohler, Jillian Clare

    2010-01-04

    In September 2003, the Canadian government committed to developing legislation that would facilitate greater access to affordable medicines for developing countries. Over the course of eight months, the legislation, now known as Canada's Access to Medicines Regime (CAMR), went through a controversial policy development process and the newspaper media was one of the major venues in which the policy debates took place. The purpose of this study was to examine how the media framed CAMR to determine how policy goals were conceptualized, which stakeholder interests controlled the public debate and how these variables related to the public policy process. We conducted a qualitative content analysis of newspaper coverage of the CAMR policy and implementation process from 2003-2008. The primary theoretical framework for this study was framing theory. A total of 90 articles from 11 Canadian newspapers were selected for inclusion in our analysis. A team of four researchers coded the articles for themes relating to access to medicines and which stakeholders' voice figured more prominently on each issue. Stakeholders examined included: the research-based industry, the generic industry, civil society, the Canadian government, and developing country representatives. The most frequently mentioned themes across all documents were the issues of drug affordability, intellectual property, trade agreements and obligations, and development. Issues such as human rights, pharmaceutical innovation, and economic competitiveness got little media representation. Civil society dominated the media contents, followed far behind by the Canadian government, the research-based and generic pharmaceutical industries. Developing country representatives were hardly represented in the media. Media framing obscured the discussion of some of the underlying policy goals in this case and failed to highlight issues which are now significant barriers to the use of the legislation. Using the media to engage

  17. PLAT: An Automated Fault and Behavioural Anomaly Detection Tool for PLC Controlled Manufacturing Systems.

    Science.gov (United States)

    Ghosh, Arup; Qin, Shiming; Lee, Jooyeoun; Wang, Gi-Nam

    2016-01-01

    Operational faults and behavioural anomalies associated with PLC control processes take place often in a manufacturing system. Real time identification of these operational faults and behavioural anomalies is necessary in the manufacturing industry. In this paper, we present an automated tool, called PLC Log-Data Analysis Tool (PLAT) that can detect them by using log-data records of the PLC signals. PLAT automatically creates a nominal model of the PLC control process and employs a novel hash table based indexing and searching scheme to satisfy those purposes. Our experiments show that PLAT is significantly fast, provides real time identification of operational faults and behavioural anomalies, and can execute within a small memory footprint. In addition, PLAT can easily handle a large manufacturing system with a reasonable computing configuration and can be installed in parallel to the data logging system to identify operational faults and behavioural anomalies effectively.

  18. PLAT: An Automated Fault and Behavioural Anomaly Detection Tool for PLC Controlled Manufacturing Systems

    Directory of Open Access Journals (Sweden)

    Arup Ghosh

    2016-01-01

    Full Text Available Operational faults and behavioural anomalies associated with PLC control processes take place often in a manufacturing system. Real time identification of these operational faults and behavioural anomalies is necessary in the manufacturing industry. In this paper, we present an automated tool, called PLC Log-Data Analysis Tool (PLAT that can detect them by using log-data records of the PLC signals. PLAT automatically creates a nominal model of the PLC control process and employs a novel hash table based indexing and searching scheme to satisfy those purposes. Our experiments show that PLAT is significantly fast, provides real time identification of operational faults and behavioural anomalies, and can execute within a small memory footprint. In addition, PLAT can easily handle a large manufacturing system with a reasonable computing configuration and can be installed in parallel to the data logging system to identify operational faults and behavioural anomalies effectively.

  19. Reliability Analysis of Safety Grade PLC(POSAFE-Q) for Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, J. Y.; Lyou, J.; Lee, D. Y.; Choi, J. G.; Park, W. M.

    2006-01-01

    The Part Count Method of the military standard MILHDK- 217F has been used for the reliability prediction of the nuclear field. This handbook determines the Programmable Logic Controller (PLC) failure rate by summing the failure rates of the individual component included in the PLC. Normally it is easily predictable that the components added for the fault detection improve the reliability of the PLC. But the application of this handbook is estimated with poor reliability because of the increased component number for the fault detection. To compensate this discrepancy, the quantitative reliability analysis method is suggested using the functional separation model in this paper. And it is applied to the Reactor Protection System (RPS) being developed in Korea to identify any design weak points from a safety point of view

  20. The Research about Embedded Soft PLC Running System Based on ARM

    Directory of Open Access Journals (Sweden)

    Fang Ding

    2014-09-01

    Full Text Available The paper discusses the overall construction and operational principle of soft PLC. Considering the real time request of the system, we use Linux+RTAI dual core system as software platform. In this platform, the implementation method of soft PLC operational system is introduced. Especially, the design of instruction analysis module is emphasized. On the basis of energy flow concept, the logic algorithm is established, aligning to the left bus. Finally, the system is tested to evaluate the desired control behavior.

  1. Development of Safety Grade PLC (POSAFE-Q) and Performance Test Results

    International Nuclear Information System (INIS)

    Kim, Chang Hwoi; Park, Won Man; Choi, Jong Gyun; Lee, Dong Young; No, Young Hun; Song, Seung Hwan

    2006-01-01

    The safety grade PLC (POSAFE-Q) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as the RTOS and firmware are being developed according to the safety critical software life cycle. Especially, the formal method is applied to design the SRS (Software Requirement Spec.) and the SDS (Software Design Specification.) to be error-free. The POSAFE-Q has several modules such as processor module, input and output modules, communication modules, redundant processor module, redundant power modules, etc,. To verify the function and performance, several tests such as CT, IT and ST were performed. And also, the equipment qualification test for environment, EMI and EMC, and seismic ware performed. All tests are satisfied with the requirements and specification for safety grade PLC, and the criteria for safety system in nuclear power plants

  2. Development of Safety Grade PLC (POSAFE-Q) and Performance Test Results

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hwoi; Park, Won Man; Choi, Jong Gyun; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of); No, Young Hun; Song, Seung Hwan [POSCON, Seoul (Korea, Republic of)

    2006-07-01

    The safety grade PLC (POSAFE-Q) is being developed in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as the RTOS and firmware are being developed according to the safety critical software life cycle. Especially, the formal method is applied to design the SRS (Software Requirement Spec.) and the SDS (Software Design Specification.) to be error-free. The POSAFE-Q has several modules such as processor module, input and output modules, communication modules, redundant processor module, redundant power modules, etc,. To verify the function and performance, several tests such as CT, IT and ST were performed. And also, the equipment qualification test for environment, EMI and EMC, and seismic ware performed. All tests are satisfied with the requirements and specification for safety grade PLC, and the criteria for safety system in nuclear power plants.

  3. Praksisnær skoleudvikling og PLC som strategisk udviklingsaktør

    DEFF Research Database (Denmark)

    Christensen, Ole; Bach, Anna

    2017-01-01

    I det følgende belyses, hvorledes PLC kan udvikles som strategisk udviklingsaktør og understøtte praksisnær skoleudvikling. Vi ønsker at belyse hvorledes Bekendtgørelsens overordnede intentioner kan få retning og rammer og dermed medvirke til, at hele det pædagogiske personale indgår i skoleudvik......I det følgende belyses, hvorledes PLC kan udvikles som strategisk udviklingsaktør og understøtte praksisnær skoleudvikling. Vi ønsker at belyse hvorledes Bekendtgørelsens overordnede intentioner kan få retning og rammer og dermed medvirke til, at hele det pædagogiske personale indgår i...... skoleudviklingen. I den forbindelse er det vores erfaring, at PLC kan spille en central rolle i forbindelse med den praksisnære og lokale skoleudvikling. Erfaringerne bygger især på udviklings- og forskningsprojekter fra kommunerne Kolding, København, Roskilde og Tårnby. Der har været tale om praksisnære...

  4. Slovak Electric, Plc., 1998

    International Nuclear Information System (INIS)

    1997-06-01

    Slovenske elektrarne, a.s. (Slovak Electric, Plc., abbrevation 'SE, a.s.') is the Slovak electricity generating utility, incorporated on November 1, 1994 as one of new companies formed from substantially all of the assets and a legal successor of Slovensky energeticky podnik, s.p., founded on January 1, 1969 in the form of SEP group. From its predecessor, Slovak Electric, Plc., took over generation of power, operation of 220 kV and 400 kV power system, transit, import, export, and sale of electricity. It is also involved in generation, distribution, and sale of heat. At present, SE's share of electriciry sales in the Slovak Republic is 88.47%. Electricity is delivered to three regional distribution companies and directly to several major industrial enterprises. SE, a.s. operates one nuclear power station, three thermal power plants, and 30 hydro power plants. The second nuclear power plant is under construction (state up tu June 1997) and SE is participating in the construction of two hydro power plants and one combined cycle power plant. The efforts of SE, s.a. focus on the generation of power and heat with minimal environmental impacts. Ecology is given priority in the SE, a.s. development programmes. SE's mission is to permanently satisfy customers' needs, for an acceptable price and with minimal environmental impact. On this CD ROM next chapters are presented: (1) The structure of the Company; (2) Production units; (3) The economic power of the Company; (4) The operation culture; (5) The strategic plans of the Company

  5. Applying Hamming Code to Memory System of Safety Grade PLC (POSAFE-Q) Processor Module

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Taehee; Hwang, Sungjae; Park, Gangmin [POSCO Nuclear Technology, Seoul (Korea, Republic of)

    2013-05-15

    If some errors such as inverted bits occur in the memory, instructions and data will be corrupted. As a result, the PLC may execute the wrong instructions or refer to the wrong data. Hamming Code can be considered as the solution for mitigating this mis operation. In this paper, we apply hamming Code, then, we inspect whether hamming code is suitable for to the memory system of the processor module. In this paper, we applied hamming code to existing safety grade PLC (POSAFE-Q). Inspection data are collected and they will be referred for improving the PLC in terms of the soundness. In our future work, we will try to improve time delay caused by hamming calculation. It will include CPLD optimization and memory architecture or parts alteration. In addition to these hamming code-based works, we will explore any methodologies such as mirroring for the soundness of safety grade PLC. Hamming code-based works can correct bit errors, but they have limitation in multi bits errors.

  6. A Research on Seamless Platform Change of Reactor Protection System From PLC to FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Junbeom; Lee, Jonghoon [Konkuk Univ., Seoul (Korea, Republic of); Lee, Jangsoo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-08-15

    The PLC (Programmable Logic Controller) has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems). Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array). Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea.

  7. A Research on Seamless Platform Change of Reactor Protection System From PLC to FPGA

    International Nuclear Information System (INIS)

    Yoo, Junbeom; Lee, Jonghoon; Lee, Jangsoo

    2013-01-01

    The PLC (Programmable Logic Controller) has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems). Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array). Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea

  8. Applying Hamming Code to Memory System of Safety Grade PLC (POSAFE-Q) Processor Module

    International Nuclear Information System (INIS)

    Kim, Taehee; Hwang, Sungjae; Park, Gangmin

    2013-01-01

    If some errors such as inverted bits occur in the memory, instructions and data will be corrupted. As a result, the PLC may execute the wrong instructions or refer to the wrong data. Hamming Code can be considered as the solution for mitigating this mis operation. In this paper, we apply hamming Code, then, we inspect whether hamming code is suitable for to the memory system of the processor module. In this paper, we applied hamming code to existing safety grade PLC (POSAFE-Q). Inspection data are collected and they will be referred for improving the PLC in terms of the soundness. In our future work, we will try to improve time delay caused by hamming calculation. It will include CPLD optimization and memory architecture or parts alteration. In addition to these hamming code-based works, we will explore any methodologies such as mirroring for the soundness of safety grade PLC. Hamming code-based works can correct bit errors, but they have limitation in multi bits errors

  9. A RESEARCH ON SEAMLESS PLATFORM CHANGE OF REACTOR PROTECTION SYSTEM FROM PLC TO FPGA

    Directory of Open Access Journals (Sweden)

    JUNBEOM YOO

    2013-08-01

    Full Text Available The PLC (Programmable Logic Controller has been widely used to implement real-time controllers in nuclear RPSs (Reactor Protection Systems. Increasing complexity and maintenance cost, however, are now demanding more powerful and cost-effective implementation such as FPGA (Field-Programmable Gate Array. Abandoning all experience and knowledge accumulated over the decades and starting an all-new development approach is too risky for such safety-critical systems. This paper proposes an RPS software development process with a platform change from PLC to FPGA, while retaining all outputs from the established development. This paper transforms FBD designs of the PLC-based software development into a behaviorally-equivalent Verilog program, which is a starting point of a typical FPGA-based hardware development. We expect that the proposed software development process can bridge the gap between two software developing approaches with different platforms, such as PLC and FPGA. This paper also demonstrates its effectiveness using an example of a prototype version of a real-world RPS in Korea.

  10. A Remote PLC Laboratory (RLab) for Distance Practical Work of Industrial Automation

    Science.gov (United States)

    Haritman, E.; Somantri, Y.; Wahyudin, D.; Mulyana, E.

    2018-02-01

    A laboratory is an essential equipment for engineering students to do a useful practical work. Therefore, universities should provide an adequate facility for practical work. On the other hand, industrial automation laboratory would offer students beneficial experience by using various educational PLC kits. This paper describes the development of Web-based Programmable Logic Controller (PLC) remote laboratory called RLab. It provides an environment for learners to study PLC application to control the level of the non-interacting tank. The RLab architecture is based on a Moodle and Remote Desktop, which also manages the booking system of the schedule of practical work in the laboratory. The RLab equipped by USB cameras providing a real-time view of PLC environment. To provide a secured system, the RLab combines Moodle and Remote Desktop application for the authentication system and management of remote users. Moodle will send PartnerID and password to connect to TeamViewer. It has been examined that the laboratory requirement, time and flexibility restrictions constitute a significant obstacle facing traditional students desiring to finish the course. A remote access laboratory can be eliminating time and flexibility restrictions. The preliminary study of RLab usability proved that such system is adequate to give the learners a distance practical work environment.

  11. Stalling autophagy: a new function for Listeria phospholipases

    Directory of Open Access Journals (Sweden)

    Ivan Tattoli

    2014-01-01

    Full Text Available Listeria monocytogenes is a Gram-positive bacterial pathogen that induces its own uptake in non-phagocytic cells. Following invasion, Listeria escapes from the entry vacuole through the secretion of a pore-forming toxin, listeriolysin O (LLO that acts to damage and disrupt the vacuole membrane. Listeria then replicates in the cytosol and is able to spread from cell-to-cell using actin-based motility. In addition to LLO, Listeria produces two phospholipase toxins, a phosphatidylinositol-specific phospholipase C (PI-PLC, encoded by plcB and a broad-range phospholipase C (PC-PLC, encoded by plcA, which contribute to bacterial virulence. It has long been recognized that secretion of PI- and PC-PLC enables the disruption of the double membrane vacuole during cell-to-cell spread, and those phospholipases have also been shown to augment LLO-dependent escape from the entry endosome. However, a specific role for Listeria phospholipases during the cytosolic stage of infection has not been previously reported. In a recent study, we demonstrated that Listeria PI-PLC and PC-PLC contribute to the bacterial escape from autophagy through a mechanism that involves direct inhibition of the autophagic flux in the infected cells [Tattoli et al. EMBO J (2013, 32, 3066-3078].

  12. Equity valuation of Tesco Plc.

    OpenAIRE

    Schmitz, Clemens

    2015-01-01

    This dissertation aimed to value the British retailer Tesco Plc. The objective was to determine a target price for the company and as a consequence determine a buy or sell recommendation when comparing it to the current market price. After the state of the art of literature regarding equity valuation has been assessed, the retail industry as well as Tesco have been analysed in more detail. Based on this, the retail business of Tesco has been valued using the Adjusted Present Va...

  13. Development of the safety PLC for plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hwoi; Lee, Dong Young [Korea Atomic Energy Research Institute, Taejeon (Korea, Republic of)

    2005-11-15

    The safety PLC (POSAFE-Q) is developing in the Korea Nuclear Instrumentation and Control System (KNICS) R and D project. The PLC satisfies Safety Class 1E, Quality Class 1, and Seismic Category I. The software such as RTOS and firmware are developed according to safety critical software life cycle. Especially, the formal method is applied to design SRS (Software Requirement Spec.) and SDS (Software Design Specification.) for error-free. The developed software according to software life cycle is verified by independent software V and V team. The overall response time from an input to the outputs shall be 50ms or less. The prototype for the POSAFE-Q was developed and functional testing and equipment qualification tests have been underway.

  14. An Architecture Of Plc Ls Xbc-Dr30e Based Clean Water Controlling System

    Directory of Open Access Journals (Sweden)

    M.Jusuf Jamanawar Purba

    2017-12-01

    Full Text Available In the industrial field the good controlling system is definitely required to improve the working efficiency of a system. The type of controller PLC Programmable Logic Controller used in Clean Water Controlling System in Electrical Workshop with PLC LS XBC-DR30E. Furthermore such system consistently uses two types of component they are Relay and Timer. The clean water pump control aims to pump the water in well A to storage tank B. The pump will work when water-contained well A is marked by sensor level well A on and the water inside storage tank B is under level 3. When the water inside storage tank B is under level 2 both pumps M1 and M2 will work to fill storage tank B. on the contrary when storage tank B is above level 2 only one pump M1 works until the tank reach level 3. In addition when storage tank B is above level 3 both pumps will stop working. However along with the advancement of recent technology the above system can be controlled by using PLC Programmable Logic Controller. Therefore it is possible to apply the controlling method of PLC as the semester Vs practical module. Based on the trial performed the PLC-based clean water system is well-functioned as the working description compiled before the operation of the tool.

  15. PC communication

    International Nuclear Information System (INIS)

    Oh, Jae Cheol

    1992-03-01

    This text book is comprised of five charters, which is about PC communication for beginners who need to learn manners and how to use Ketel and PC serve. So it introduces first, conception of PC and precautions on using PC communication, second, preparation for PC communication with Modem, its program, install, kinds of protocol and how to use protocol, third directions of emulator of PC communication and super session, fourth, instruction of Ketel with join and access, basic command of Ketel, list of Ketel's menu, Ketel editor, service guide, directions of News service, Stock and bond service business and economic figures, exchange rate and interest rate, tax culture and leisure, Ketel BBS service and posting. The last part has a instruction of PC-serve about join, basic command of PC-serve, service guide and practical guideline.

  16. PC communication

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jae Cheol

    1992-03-15

    This text book is comprised of five charters, which is about PC communication for beginners who need to learn manners and how to use Ketel and PC serve. So it introduces first, conception of PC and precautions on using PC communication, second, preparation for PC communication with Modem, its program, install, kinds of protocol and how to use protocol, third directions of emulator of PC communication and super session, fourth, instruction of Ketel with join and access, basic command of Ketel, list of Ketel's menu, Ketel editor, service guide, directions of News service, Stock and bond service business and economic figures, exchange rate and interest rate, tax culture and leisure, Ketel BBS service and posting. The last part has a instruction of PC-serve about join, basic command of PC-serve, service guide and practical guideline.

  17. PLC based control system and maintenance activities at NCAR, Bilaspur

    International Nuclear Information System (INIS)

    Dewangan, Jaidev; Trivedi, T.; Patel, Shiv P.; Malik, C.; Kumar, Rakesh; Gupta, Santosh Kumar; Bajpai, P.K.

    2015-01-01

    A 3.0 MV high current low energy Pelletron Accelerator facility (Model 9SDH-4, NEC, USA) with TORUIS (ion source for H + and He 2+ beam current H + ion ∼ 50μA @ 6 MeV, He 2+ at ∼ 10μA) and SNICS-II ion source for heavy ions has been commissioned as 'National Centre for Accelerator Based Research' in the Department of Pure and Applied Physics, Guru Ghasidas Vishwavidyalaya. In this paper, we detail out the control system developed and implemented at NCAR. The basic idea of controlling the machine is by providing the output signal through PLC to ACPC of accelerator using user interface points provided by the manufacturer. The PLC based system generates output signal once it receives the feedback signals from search and secure switches, door lock switches and scram switches interlocked with PLC. The output is controlled by ladder logic and is activated only when all the radiation monitors are in healthy state and outside radiations monitor having low radiation level. The details of control system and maintenance activities will be discussed in the paper

  18. Cable-stayed PC bridge with inclined main tower. Hachinohe port island bridge; Keisha shuto to yusuru 2 keikan renzoku PC shachokyo. Hachinoheko port island renrakykyo (kasho)

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, A. [Hachinohe Institute of Technology, Aomori (Japan)

    1994-09-15

    The design and construction of the inclined main bridge, which is being constructed at the mouth of the Hachinohe Harbor (in Japan), are outlined in this paper. This connecting bridge has an overall length of 265.56 m, and consists of the main bridge member of asymmetric 2 cable-stayed PC bridge and the 3 cable-stayed PC box member bridge. An asymmetric design was employed for the main bridge frame to ensure the access space for small ships passing between bridge girders, easy maintenance and service, improved economy, and excellent view. The main tower is a single-pillar reinforced concrete structure with an inclination of 15{degree} and 47 m in height. Forty-eight diagonal cables are arranged so that 12 cable trains are connected to the main tower on the right and left sides respectively, and the back-stay cable structure is used for each upper 3 cable trains to improve safety against the earthquake. The main beam is made by a prestressed concrete structure with inverse trapezoidal 3-chamber frame section. This structure is superior in increasing the safety against wind. Steel tube sheet-pile well is selected for the bridge pier base, and debris layer is selected as a support layer for the base. For the construction of the lower bridge section, sand conversion through predrilling of rubble-mound and debris layer was executed. The underwater non-separative concrete and embedded type frame are used around the bridge piers and its surrounding. For the construction of the upper bridge section, steel frames are used inside the main tower to ensure the construction precision. 7 figs.

  19. Enterprise network with software Asterisk PBX based on the PLC technology

    Directory of Open Access Journals (Sweden)

    Michal Maar

    2017-01-01

    Full Text Available This article presents the software Asterisk PBX solution design in enterprise PLC network (Power Line Communication. The description of the installation and configuration of software Asterisk PBX is involved in the design. The secure interconnection of two enterprise PLC network is implemented via the telecommunication tunnel with security grant using the Cisco routers. The connection between two Asterisk PBXs is designed in context of the establishment of the tunnel. The subject of the article is also cross/connection of exchanges Asterisk PBX and hardware PBX - IP Panasonic PBX K-NS500.

  20. Multi-satellite study of the excitation of Pc3 and Pc4-5 ULF waves and their penetration across the plasmapause during the 2003 Halloween superstorm

    Directory of Open Access Journals (Sweden)

    G. Balasis

    2015-10-01

    Full Text Available We use multi-satellite and ground-based magnetic data to investigate the concurrent characteristics of Pc3 (22–100 mHz and Pc4-5 (1–22 mHz ultra-low-frequency (ULF waves on the 31 October 2003 during the Halloween magnetic superstorm. ULF waves are seen in the Earth's magnetosphere, topside ionosphere, and Earth's surface, enabling an examination of their propagation characteristics. We employ a time–frequency analysis technique and examine data from when the Cluster and CHAMP spacecraft were in good local time (LT conjunction near the dayside noon–midnight meridian. We find clear evidence of the excitation of both Pc3 and Pc4-5 waves, but more significantly we find a clear separation in the L shell of occurrence of the Pc4-5 and Pc3 waves in the equatorial inner magnetosphere, separated by the density gradients at the plasmapause boundary layer. A key finding of the wavelet spectral analysis of data collected from the Geotail, Cluster, and CHAMP spacecraft and the CARISMA and GIMA magnetometer networks was a remarkably clear transition of the waves' frequency into dominance in a higher-frequency regime within the Pc3 range. Analysis of the local field line resonance frequency suggests that the separation of the Pc4-5 and Pc3 emissions across the plasmapause is consistent with the structure of the inhomogeneous field line resonance Alfvén continuum. The Pc4-5 waves are consistent with direct excitation by the solar wind in the plasma trough, as well as Pc3 wave absorption in the plasmasphere following excitation by upstream waves originating at the bow shock in the local noon sector. However, despite good solar wind coverage, our study was not able to unambiguously identify a clear explanation for the sharp universal time (UT onset of the discrete frequency and large-amplitude Pc3 wave power.

  1. β Absorption dust concentration monitor system based on the PLC

    International Nuclear Information System (INIS)

    Lian Dexing; Zhou Xiuliang; Liu Liyan; Li Zonglun; Cao Guanghui; Mao Wanchong

    2011-01-01

    To provide an on-line automatic system for dust concentration monitor is the purpose of this design.The system based on β-ray-absorption-method,employing PLC (Programmable Logic Controller) control technology, is presented. The user input parameter setup,the data acquisition and processing, and the communication with computer can be effectively regulated using the advanced PLC control technology. It has the features of high reliability, easy operation and easy maintenance, and the ability to monitor remotely. Measurement range: 0.1-1500 mg/m 3 , Accuracy: ±9%. The structure,working principle, electric circuit and software development of the system are introduced in detail. (authors)

  2. Bringing Automated Model Checking to PLC Program Development - A CERN Case Study

    CERN Document Server

    Fernandez Adiego, B; Tournier, J-C; Blanco Vinuela, E; Gonzalez Suarez, V M

    2014-01-01

    Verification of critical software is a high priority but a challenging task for industrial control systems. Model checking appears to be an appropriate approach for this purpose. However, this technique is not widely used in industry yet, due to some obstacles. The main obstacles encountered when trying to apply formal verification techniques at industrial installations are the difficulty of creating models out of PLC programs and defining formally the specification requirements. In addition, models produced out of real-life programs have a huge state space, thus preventing the verification due to performance issues. Our work at CERN (European Organization for Nuclear Research) focuses on developing efficient automatic verification methods for industrial critical installations based on PLC (Programmable Logic Controller) control systems. In this paper, we present a tool generating automatically formal models out of PLC code. The tool implements a general methodology which can support several input languages, ...

  3. Design of real-time communication system for image recognition based colony picking instrument

    Science.gov (United States)

    Wang, Qun; Zhang, Rongfu; Yan, Hua; Wu, Huamin

    2017-11-01

    In order to aachieve autommated observatiion and pickinng of monocloonal colonies, an overall dessign and realizzation of real-time commmunication system based on High-throoughput monooclonal auto-piicking instrumment is propossed. The real-time commmunication system is commposed of PCC-PLC commuunication systtem and Centrral Control CComputer (CCC)-PLC communicatioon system. Bassed on RS232 synchronous serial communnication methood to develop a set of dedicated shoort-range commmunication prootocol betweenn the PC and PPLC. Furthermmore, the systemm uses SQL SSERVER database to rrealize the dataa interaction between PC andd CCC. Moreoover, the commmunication of CCC and PC, adopted Socket Ethernnet communicaation based on TCP/IP protoccol. TCP full-dduplex data cannnel to ensure real-time data eexchange as well as immprove system reliability andd security. We tested the commmunication syystem using sppecially develooped test software, thee test results show that the sysstem can realizze the communnication in an eefficient, safe aand stable way between PLC, PC andd CCC, keep thhe real-time conntrol to PLC annd colony inforrmation collecttion.

  4. Bringing Automated Formal Verification to PLC Program Development

    CERN Document Server

    Fernández Adiego, Borja; Blanco Viñuela, Enrique

    Automation is the field of engineering that deals with the development of control systems for operating systems such as industrial processes, railways, machinery or aircraft without human intervention. In most of the cases, a failure in these control systems can cause a disaster in terms of economic losses, environmental damages or human losses. For that reason, providing safe, reliable and robust control systems is a first priority goal for control engineers. Ideally, control engineers should be able to guarantee that both software and hardware fulfill the design requirements. This is an enormous challenge in which industry and academia have been working and making progresses in the last decades. This thesis focuses on one particular type of control systems that operates industrial processes, the PLC (Programmable Logic Controller) - based control systems. Moreover it targets one of the main challenges for these systems, guaranteeing that PLC programs are compliant with their specifications. Traditionally ...

  5. 76 FR 52288 - Airworthiness Directives; Rolls-Royce plc (RR) Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-08-22

    ...-0836; Directorate Identifier 2010-NE-38-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom: telephone 44 (0) 1332 242424; fax 44 (0) 1332... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  6. A PLC generic requirements and specification for safety-related applications in nuclear power plants

    International Nuclear Information System (INIS)

    Han, Jea Bok; Lee, C. K.; Lee, D. Y.

    2001-12-01

    This report presents the requirements and specification to be applied to the generic qualification of programmable Logic Controller(PLC), which is being developed as part of the KNICS project, 'Development of the Digital Reactor Safety Systems' of which purpose is the application to safety-related instrumentation and control systems in nuclear power plants. This report defines the essential and critical characteristics that shall be included as part of a PLC design for safety-related application. The characteristics include performance, reliability, accuracy, the overall response time from an input to the PLC exceeding it trip condition to the resulting outputs, and the specification of processors and memories in digital controller. It also specifies the quality assurance process for software development, dealing with executive software, firmware, application software tools for developing the application software, and human machine interface(HMI). In addition, this report reviews the published standards and guidelines that are required for the PLC development and the quality assurance processes such as environment requirements, seismic withstand requirements, EMI/RFI withstand requirements, and isolation test

  7. Technical considerations for the development of an engineering safety features control system with PLC

    International Nuclear Information System (INIS)

    Lee, C. K.; Kim, C. H.; Han, J. B.; Kim, H.; Lee, S. S.

    2002-01-01

    Technical considerations are summarized for the development of an ESFCS(Engineered Safety Features Control System) with PLC (Programmable Logic Controller). The ESFCS is required for the mitigation of plant accident conditions and therefore developed in conformance with the design requirements applied to the safety critical system. The design of ESFCS primarily considered its safety, and the system has an architecture that will be able to minimize spurious actuation. The PLC based functional distribution and redundant design features are adopted, and the fieldbus is applied in the communication of information and control signals between PLC processors. It is expected that the ESFCS will have several advanced design features compared with the conventional systems supplied by foreign vendors

  8. The YvfTU Two-component System is involved in plcR expression in Bacillus cereus

    NARCIS (Netherlands)

    Brillard, Julien; Susanna, Kim; Michaud, Caroline; Dargaignaratz, Claire; Gohar, Michel; Nielsen-Leroux, Christina; Ramarao, Nalini; Kolsto, Anne-Brit; Nguyen-The, Christophe; Lereclus, Didier; Broussolle, Veronique

    2008-01-01

    Background: Most extracellular virulence factors produced by Bacillus cereus are regulated by the pleiotropic transcriptional activator PlcR. Among strains belonging to the B. cereus group, the plcR gene is always located in the vicinity of genes encoding the YvfTU two-component system. The putative

  9. Amersham International plc. Report and Accounts 1995

    International Nuclear Information System (INIS)

    1995-01-01

    The Annual Report and Accounts for Amersham International plc for the year 1995 are presented. This leading health science company develops products, services and technologies based on its expertise in labelling and detection at the molecular level. Recent work in the fields of life science research, nuclear medicine and industrial quality and safety assurance are described. (UK)

  10. Csseverin inhibits apoptosis through mitochondria-mediated pathways triggered by Ca2 + dyshomeostasis in hepatocarcinoma PLC cells.

    Directory of Open Access Journals (Sweden)

    Mengchen Shi

    2017-11-01

    Full Text Available Numerous experimental and epidemiological studies have demonstrated a link between Clonorchis sinensis (C. sinensis infestation and cholangiocarcinoma (CCA as well as hepatocellular carcinoma (HCC. The underlying molecular mechanism involved in the malignancy of CCA and HCC has not yet been addressed. Csseverin, a component of the excretory/secretory products of C. sinensis (CsESPs, was confirmed to cause obvious apoptotic inhibition in the human HCC cell line PLC. However, the antiapoptotic mechanism is unclear. In the present study, we investigated the cellular features of the antiapoptotic mechanism upon transfection of the Csseverin gene.In the present study, we evaluated the effects of Csseverin gene overexpression on the apoptosis of PLC cells using an Annexin PE/7-AAD assay. Western blotting was applied to quantify the activation of caspase-3 and caspase-9, the mitochondrial translocation of Bax and the release of Cyt c upon Csseverin overexpression in PLC cells. Laser scanning confocal microscopy was used to analyze the changes of intracellular calcium. Fluorescence assay and immunofluorescence assays were performed to observe the changes of the mitochondrial permeability transition pore (MPTP.The overexpression of Csseverin in PLC cells showed apoptosis resistance after the induction of apoptosis. Additionally, the activation of caspase-3 and caspase-9 was specifically weakened in Csseverin overexpression PLC cells. The overexpression of Csseverin reduced the increase in intracellular free Ca2+, thereby inhibiting MPTP opening in PLC cells. Moreover, Bax mitochondrial translocation and the subsequent release of Cyt c were downregulated in apoptotic Csseverin overexpression PLC cells.The present findings suggest that Csseverin, a component of CsESPs, confers protection from human HCC cell apoptosis via the inactivation of membranous Ca2+ channels. Csseverin might be involved in the process of HCC through C. sinensis infestation in

  11. 76 FR 24796 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-05-03

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation.... Request To Revise the Compliance Times Four commenters, American Airlines, Delta Airlines, Rolls-Royce plc... SNPRM were developed to minimize the risk of uncontained disc failure, based on the age of the parts in...

  12. Session 1984-1985. Radioactive waste. Minutes of evidence, Monday 13 May 1985. British Nuclear Fuels plc

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    The Environment Select Committee of the House of Commons received a memorandum from British Nuclear Fuels plc on the treatment and preparation for disposal of radioactive wastes, under the headings: introduction; waste categories; waste management policy; waste arisings; waste treatment plans; appendix I - British Nuclear Fuels plc; appendix II - the nuclear fuel cycle for Magnox, AGR and LWR reactors; appendix III - control of liquid radioactive discharges from Sellafield and their environmental impact. Representatives of BNF plc were examined on the subject of the memorandum and the minutes of evidence are recorded.

  13. Session 1984-85. Radioactive waste. Minutes of evidence, Monday 13 May 1985. British Nuclear Fuels plc

    International Nuclear Information System (INIS)

    1985-01-01

    The Environment Select Committee of the House of Commons received a memorandum from British Nuclear Fuels plc on the treatment and preparation for disposal of radioactive wastes, under the headings: introduction; waste categories; waste management policy; waste arisings; waste treatment plans; appendix I - British Nuclear Fuels plc; appendix II - the nuclear fuel cycle for Magnox, AGR and LWR reactors; appendix III - control of liquid radioactive discharges from Sellafield and their environmental impact. Representatives of BNF plc were examined on the subject of the memorandum and the minutes of evidence are recorded. (U.K.)

  14. 70Z/3 Cbl induces PLC gamma 1 activation in T lymphocytes via an alternate Lat- and Slp-76-independent signaling mechanism.

    Science.gov (United States)

    Graham, Laurie J; Verí, Maria-Concetta; DeBell, Karen E; Noviello, Cristiana; Rawat, Rashmi; Jen, Sandy; Bonvini, Ezio; Rellahan, Barbara

    2003-04-24

    The oncoprotein 70Z/3 Cbl signals in an autonomous fashion or through blockade of endogenous c-Cbl, a negative regulator of signaling. The mechanism of 70Z/3 Cbl-induced signaling was investigated by comparing the molecular requirements for 70Z/3 Cbl- and TCR-induced phospholipase C gamma 1 (PLC gamma 1) activation. 70Z/3 Cbl-induced PLC gamma 1 tyrosine phosphorylation required, in addition to the PLC gamma 1 N-terminal SH2 domain, the C-terminal SH2 and SH3 domains that were dispensable for TCR-induced phosphorylation. Deletion of the leucine zipper of 70Z/3 Cbl did not eliminate 70Z/3 Cbl-induced PLC gamma 1 phosphorylation, suggesting that blockage of c-Cbl via dimerization with 70Z/3 Cbl cannot fully explain 70Z/3 Cbl activating characteristics. The complete elimination of PLC gamma 1 phosphorylation required deleting the SH3 domain-binding region of 70Z/3 Cbl, consistent with 70Z/3 Cbl binding the PLC gamma 1 SH3 domain. 70Z/3 Cbl-induced PLC gamma 1 phosphorylation required Zap-70, as for the TCR, and the tyrosine kinase binding domain of 70Z/3 Cbl, which binds Zap-70, but did not require PLC gamma 1 binding to Lat, a crucial interaction in TCR-induced PLC gamma 1 phosphorylation. Furthermore, 70Z/3 Cbl-induced activation of NFAT, a PLC gamma 1/Ca(2+)-dependent transcriptional event, required Zap-70, but was independent of Slp-76, an adapter required for TCR-induced NFAT activation. These results suggest that 70Z/3 Cbl and PLC gamma 1 form a TCR-, Lat- and Slp-76-independent complex that leads to PLC gamma 1 phosphorylation and activation.

  15. Application of PLC technology in measurement of beam profile on 100 MeV accelerator

    International Nuclear Information System (INIS)

    Yu Luyang; Chinese Academy of Sciences, Beijing; Chen Yongzhong; Chen Yongzhong; Liu Dekang; Chinese Academy of Sciences, Beijing

    2005-01-01

    A comprehensive introduction is given to the real-time measuring method, which is based on the Programmable Logic Controller (PLC) technology and can measure intensity and profile of the beam by a scintillator screen. The whole system has many advantages, such as good reliability, high precision, intuitional measurement, etc. due to the use of the PLC and Labview software. (authors)

  16. Migration towards Windows 2000/XP

    International Nuclear Information System (INIS)

    Gal, J.

    2004-01-01

    The article deals with interesting technical solutions used in the project 'Migration towards Windows 2000/XP', which was introduced by the company AITEN, Plc for companies SE Plc, SEPS Plc and TEKO, Plc in the period 2002 and 2003. The contents of the project was migration of about 100 servers and more than 4 000 PC to the Windows 2000 and XP environs. The result of the project is a unified and documented system in the field of file, print and small application servers and PC. It has enabled to increase the system reliability and availability, to decrease the total costs for administration and operation and to establish the steady environs for users of the applications. (author)

  17. PowerGen plc report and accounts 1994

    International Nuclear Information System (INIS)

    1994-01-01

    The annual report and accounts of PowerGen plc for the year 1994 are presented. Financial highlights are quoted, followed by the Chairman's statement, reviews by the Chief Executive and Financial Directors, reports by the Auditors and Directors, balance sheets and details of the consolidated profit and loss account and principal accounting policies. A four year summary and shareholder information are included. (UK)

  18. Design and experimental study on columns and beams connection in the precast prestressed concrete structure. Precast PC acchaku setsugo ni kansuru sekkeiho to jikkenteki kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, K. (Kurosawa Construction Co. Ltd., Tokyo (Japan))

    1993-07-30

    Design engineering and experimental study were made of precast PC clad connection. The clad connection method between the columns and beams is classified into bracket method, shearing key method, corbel method and reinforcing structure-jointing method, among which the corbel method is recommendable because of its simplicity without slip. The PC clad connection system is characterized by its possibility of structuring the continuous multi-rahmen structure, designing the highest strength concrete and easing the earthquake-proof design with a high toughness restoring force. The PC cable wiring method is classified into X-cross method and continuous method. The design of PC clad connection was experimentally proved by alternately loading the frame. Through the experiment, the interstory deformation angle, and stress behavior of the column and beam PC steel materials were made clear so that their destruction became able to be prevented. Also through the experiment, the interstory deformation angle and maximum column-shearing force were known at the yield point of beam, which had the frame-restoring force characteristics modeled by a trilinear elastoplastic type. 28 refs., 13 figs.

  19. 75 FR 61114 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2010-10-04

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation.... Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, England, DE248BJ; telephone: 011-44... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  20. 75 FR 264 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2010-01-05

    ...-1004; Directorate Identifier 2009-NE-36-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc.... Contact Rolls-Royce plc, P.O. Box 31, Derby, England; telephone: 011-44-1332-249428; fax: 011-44-1332... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  1. 77 FR 1009 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines

    Science.gov (United States)

    2012-01-09

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines AGENCY: Federal Aviation... 5, 2005). ADDRESSES: For service information identified in this AD, contact Rolls-Royce plc, P.O...,000. Based on these figures, we estimate the total cost of the AD to U.S. operators to be $4,206,960...

  2. Five Year Retrospective Study of the Financial Situation of Northern Foods Plc., United Kingdom

    Directory of Open Access Journals (Sweden)

    Louie DACOSTA

    2016-09-01

    Full Text Available This study was conducted as a retrospective analysis of Northern Foods Plc., once a major player in FTSE 350 Food Sector, to evaluate its financial situation over a five year period. The ex post factor research design was used for this study. Annual reports and databases on Northern Foods Plc., and Associated British Foods Plc., were used to perform a series of ratio analyses. The results revealed that Northern Foods Plc.’s performance has been declining as evidenced in the profitability ratios calculated. Also, financial strength was weak and working capital has not been effectively managed, hence affecting its cash and profit generation potentials. The company was limited in its ability to grow and expand as it needed to regularly fund its pension deficit, and finance its high levels of debt. The study concludes that Northern Foods was not in a very strong financial position, yet it was not making the required investments to improve, hence its takeover though this paper will not rule out non-financial issues. Furthermore, the study prescribed five generic points to improve the financial health of any organisation.

  3. Application of PLC to dynamic control system for liquid He cryogenic pumping facility on JT-60U NBI system

    International Nuclear Information System (INIS)

    Honda, A.; Okano, F.; Ooshima, K.; Akino, N.; Kikuchi, K.; Tanai, Y.; Takenouchi, T.; Numazawa, S.; Ikeda, Y.

    2008-01-01

    The control system of the cryogenic facility in the JT-60 NBI system has been replaced by employing the PLC (Programmable Logic Controller) and SCADA (Supervisory Control And Data Acquisition) system. The original control system was constructed about 20 years ago by specifying the DCS (Distributed Control System) computer to deal with ∼400 feedback loops. Recently, troubles on this control system have increased due to its age-induced deterioration. To maintain the high reliability of the cryogenic facility, a new control system has been planned with the PLC and SCADA systems. Their attractive features include high market availability and cost-effectiveness, however, the use of PLC for such a large facility with ∼400 feedback loops has not been established because of insufficient processing capability of the early PLC. Meanwhile, the recent progress in the PLC enables to use the FBD (function block diagram) programming language for 500 function blocks. By optimizing the function blocks and connecting them in the FBD language, the feedback loops have been successfully replaced from DCS to PLC without a software developer. Moreover, an oscillation of the liquid He level, which often occurs during the cooldown mode of the cryopumps, can be automatically stabilized by easily adding a new process program in the PLC. At present, the new control system has worked well

  4. A PLC platform-independent structural analysis on FBD programs for digital reactor protection systems

    International Nuclear Information System (INIS)

    Jung, Sejin; Yoo, Junbeom; Lee, Young-Jun

    2017-01-01

    Highlights: • FBD has been widely used to implement safety-critical software for PLC-based systems. • The safety-critical software should be developed strictly with safety programming guidelines. • There are no argued rules that have specific links to higher guidelines NUREG/CR-6463 PLC platform-independently. • This paper proposes a set of rules on the structure of FBD programs with providing specific links to higher guidelines. • This paper also provides CASE tool ‘FBD Checker’ for analyzing the structure of FBD. - Abstract: FBD (function block diagram) has been widely used to implement safety-critical software for PLC (programmable logic controller)-based digital nuclear reactor protection systems. The software should be developed strictly in accordance with safety programming guidelines such as NUREG/CR-6463. Software engineering tools of PLC vendors enable us to present structural analyses using FBD programs, but specific rules pertaining to the guidelines are enclosed within the commercial tools, and specific links to the guidelines are not clearly communicated. This paper proposes a set of rules on the structure of FBD programs in accordance with guidelines, and we develop an automatic analysis tool for FBD programs written in the PLCopen TC6 format. With the proposed tool, any FBD program that is transformed into an open format can be analyzed the PLC platform-independently. We consider a case study on FBD programs obtained from a preliminary version of a Korean nuclear power plant, and we demonstrate the effectiveness and potential of the proposed rules and analysis tool.

  5. Restructuring of SE, Plc - from a functionally managed company to a process managed commercial-production company

    International Nuclear Information System (INIS)

    Ravasz, V.

    2004-01-01

    The purpose of this presentation is to inform the participants about present changes currently occurred within Slovenske elektrarne, a. s. (SE, Plc). Changes are related to the liberalisation of the electricity market and expected accession of Slovakia to EU. To support its competitiveness, the SE, Plc became a customer-oriented company, prepared to the access of strategic investor. The paper includes the basic information about centralisation and project of Restructuring of SE, Plc., which has started in December 2003. The aim of Restructuring is the change from functionally managed company to a process managed commercial-production company

  6. 77 FR 20987 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-04-09

    ... Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... the Federal Register. That AD applies to RB211-Trent 800 series turbofan engines. The last comment...

  7. 75 FR 61361 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engines

    Science.gov (United States)

    2010-10-05

    ...-0994; Directorate Identifier 2009-NE-39-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-Royce plc., P.O. Box 31, Derby, DE24 8BJ, United Kingdom; Telephone: 011 44 1332 242424, Fax: 011 44... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  8. 76 FR 65997 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engines

    Science.gov (United States)

    2011-10-25

    ...-0994; Directorate Identifier 2009-NE-39-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... Friday, except Federal holidays. For service information identified in this AD, contact Rolls-Royce plc.... Based on these figures, we estimate the cost of this proposed AD on U.S. operators to be $1,499,400. FAA...

  9. 76 FR 2605 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-01-14

    ... Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, DERBY, DE24 8BJ, UK; telephone 44 (0... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  10. Event notification system with a PLC

    International Nuclear Information System (INIS)

    Kawase, M.; Yoshikawa, Hiroshi; Sakaki, Hironao; Takahashi, Hiroki; Sako, Hiroyuki; Kamiya, Junichiro; Takayanagi, Tomohiro

    2004-01-01

    When an interlock occurs in the equipment, it is required to notify the upper rank control system of the Interlock and receive information for apparatus information in the upper rank control system as at high speed as possible. In the apparatus using FA-M3, it can respond to this by using the notice function of an event. This report shows the event notification system with a PLC based Kicker electromagnet power supply for 3GeV RCS. (author)

  11. PLC-based LP₁₁ mode rotator for mode-division multiplexing transmission.

    Science.gov (United States)

    Saitoh, Kunimasa; Uematsu, Takui; Hanzawa, Nobutomo; Ishizaka, Yuhei; Masumoto, Kohei; Sakamoto, Taiji; Matsui, Takashi; Tsujikawa, Kyozo; Yamamoto, Fumihiko

    2014-08-11

    A PLC-based LP11 mode rotator is proposed. The proposed mode rotator is composed of a waveguide with a trench that provides asymmetry of the waveguide. Numerical simulations show that converting LP11a (LP11b) mode to LP11b (LP11a) mode can be achieved with high conversion efficiency (more than 90%) and little polarization dependence over a wide wavelength range from 1450 nm to 1650 nm. In addition, we fabricate the proposed LP11 mode rotator using silica-based PLC. It is confirmed that the fabricated mode rotator can convert LP11a mode to LP11b mode over a wide wavelength range.

  12. Heating systems with PLC and frequency control

    International Nuclear Information System (INIS)

    Abdallah, Salah; Abu-Mallouh, Riyad

    2008-01-01

    In this work, medium capacity controlled heating system is designed and constructed. The programming method of control of heating process is achieved by means of integrated programmable logic controller (PLC) and frequency inverter (FI). The PLC main function is to determine the required temperatures levels and the related time intervals of the heating hold time in the furnace. FI is used to control the dynamic change of temperature between various operating points. The designed system shows the capability for full control of temperature from zero to maximum for any required range of time in case of increasing or decreasing the temperature. All variables of the system will be changed gradually until reaching their needed working points. An experimental study was performed to investigate the effect of tempering temperature and tempering time on hardness and fatigue resistance of 0.4% carbon steel. It was found that increasing tempering temperature above 550 deg. C or tempering time decreases the hardness of the material. It was also found that there is a maximum number of cycles to which the specimen can survive what ever the applied load was

  13. Sheep head frame validation for CT and MRI studies

    Directory of Open Access Journals (Sweden)

    marco trovatelli

    2017-05-01

    Full Text Available Abstract   Introductions Aim of EDEN 2020 project’s Milestone 5 is the development of a steerable catheter for CED system in glioblastoma therapy. The VET group is involved in realization and validation of the proper animal model. Materials and methods In this part of the study two fresh sheep’s head from the local slaughter were used. The heads were located into an ad hoc Frame system based on anatomical measures and CT images, producted by Renishaw plc partner in this project. The frame was adapted and every components were checked for the ex vivo validation tests. CT imaging was taken in Lodi at Università degli studi di Milano, Facoltà di Medicina Veterinaria, with CT scanner and MRI imaging was taken in La Cittadina, Cremona Results System validation was approved by the ex vivo trial. The frame system doesn’t compromise the imaging acquisition in MRI and CT systems. Every system components are functional to their aims. Discussion The Frame system is adapted to the sheep head. It is composed by elements able to lock the head during the imaging acquisition. Frame system is characterized by a support base helpings the animals to keep the head straight forward during imaging time, under general anesthesia. The design of these device support the airways anatomy, avoiding damaging or obstruction of airflows during anesthesia period. The role of elements like mouth bar and ovine head pins is to lock the head in a stable position during imaging acquisition; fixing is guaranteed by V shape head pins, that are arranged against the zygomatic arches. Lateral compression forces to the cranium, and the V shape pins avoid the vertical shifting of the head and any kind of rotations. (fig. 1

  14. 77 FR 4648 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engine

    Science.gov (United States)

    2012-01-31

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-535 Series Turbofan Engine AGENCY: Federal Aviation... identified in this AD, contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone: 011 44... parts are required. Based on these figures, we estimate the cost of this AD on U.S. operators to be $1...

  15. 75 FR 63727 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series Turbofan Engines

    Science.gov (United States)

    2010-10-18

    ...-0162; Directorate Identifier 2004-NE-19-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; telephone: 011-44-1332... would cost $0. Based on these figures, we estimate the total cost of the AD to U.S. operators would be...

  16. Multiprog Virtual Laboratory Applied to PLC Programming Learning

    Science.gov (United States)

    Shyr, Wen-Jye

    2010-01-01

    This study develops a Multiprog virtual laboratory for a mechatronics education designed to teach how to programme a programmable logic controller (PLC). The study was carried out with 34 students in the Department of Industry Education and Technology at National Changhua University of Education in Taiwan. In total, 17 students were assigned to…

  17. Design of EAST LHCD high power supply feedback control system based on PLC

    International Nuclear Information System (INIS)

    Hu Huaichuan; Shan Jiafang

    2009-01-01

    Design of EAST LHCD -35kV/5.6MW high power supply feedback control system based on PLC is described. Industrial computer and PLC are used to control high power supply in the system. PID arithmetic is adopted to achieve the feedback control of voltage of high power supply. Operating system is base on real-time operating system of QNX. Good controlling properties and reliable protective properties of the feedback control system are proved by the experiment results. (authors)

  18. British Nuclear Fuels plc: report and accounts 1987-88

    International Nuclear Information System (INIS)

    1989-01-01

    The Energy Committee has considered the report and accounts of BNFL (British Nuclear Fuels PLC) for the year 1987-88. The report looks at BNFL as a government owned PLC - its activities and financial performance. Various questions are raised about the underlying financial position justifying the optimism portrayed in the report and accounts. The impact of cost-plus contracts on UK customers is examined. The economics of THORP (Thermal Oxide Reprocessing Plant) are also examined especially as the escalation in the cost of constructing THORP means that a substantial loss will be made in the reprocessing of waste for which contracts were signed in the late 1960s or early 1970s. The main conclusions of the report are summarized. One of these is that the UK must be cautious about becoming a repository of foreign nuclear waste. Other specific recommendations are made - some about the decommissioning of BNFL plant. (UK)

  19. NB-PLC channel modelling with cyclostationary noise addition & OFDM implementation for smart grid

    Science.gov (United States)

    Thomas, Togis; Gupta, K. K.

    2016-03-01

    Power line communication (PLC) technology can be a viable solution for the future ubiquitous networks because it provides a cheaper alternative to other wired technology currently being used for communication. In smart grid Power Line Communication (PLC) is used to support communication with low rate on low voltage (LV) distribution network. In this paper, we propose the channel modelling of narrowband (NB) PLC in the frequency range 5 KHz to 500 KHz by using ABCD parameter with cyclostationary noise addition. Behaviour of the channel was studied by the addition of 11KV/230V transformer, by varying load location and load. Bit error rate (BER) Vs signal to noise ratio SNR) was plotted for the proposed model by employing OFDM. Our simulation results based on the proposed channel model show an acceptable performance in terms of bit error rate versus signal to noise ratio, which enables communication required for smart grid applications.

  20. The effect of a dynamic PCL brace on patellofemoral compartment pressures in PCL-and PCL/PLC-deficient knees.

    Science.gov (United States)

    Welch, Tyler; Keller, Thomas; Maldonado, Ruben; Metzger, Melodie; Mohr, Karen; Kvitne, Ronald

    2017-12-01

    The natural history of posterior cruciate ligament (PCL) deficiency includes the development of arthrosis in the patellofemoral joint (PFJ). The purpose of this biomechanical study was to evaluate the hypothesis that dynamic bracing reduces PFJ pressures in PCL- and combined PCL/posterolateral corner (PLC)-deficient knees. Controlled Laboratory Study. Eight fresh frozen cadaveric knees with intact cruciate and collateral ligaments were included. PFJ pressures and force were measured using a pressure mapping system via a lateral arthrotomy at knee flexion angles of 30°, 60°, 90°, and 120° in intact, PCL-deficient, and PCL/PLC-deficient knees under a combined quadriceps/hamstrings load of 400 N/200 N. Testing was then repeated in PCL- and PCL/PLC-deficient knees after application of a dynamic PCL brace. Application of a dynamic PCL brace led to a reduction in peak PFJ pressures in PCL-deficient knees. In addition, the brace led to a significant reduction in peak pressures in PCL/PLC-deficient knees at 60°, 90°, and 120° of flexion. Application of the dynamic brace also led to a reduction in total PFJ force across all flexion angles for both PCL- and PCL/PLC-deficient knees. Dynamic bracing reduces PFJ pressures in PCL- and combined PCL/PLC-deficient knees, particularly at high degrees of knee flexion.

  1. 77 FR 10355 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2012-02-22

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... service of certain critical engine parts based on reduced life limits. This new AD reduces the life limits... effective March 28, 2012. ADDRESSES: For service information identified in this AD, contact Rolls-Royce plc...

  2. The Application of PLC (Powerline Communications) in Brazil in the regulatory viewpoint; A aplicacao do PLC no Brasil do ponto de vista regulatorio

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Daniel; Silva Filho, Armando [Agencia Nacional de Energia Eletrica (ANEEL), Brasilia, DF (Brazil). Superintendencia de Regulacao dos Servicos de Distribuicao

    2010-07-01

    The Powerline Communications technology - PLC allows transmission of data, voice, image and access to high speed internet by the grid, so that a power plug can also be an access point to the network communication. Considering that the electric grid reaches the vast majority of households, there is great potential in using this technology as a tool to achieve the reality of digital inclusion in the country. However, its implementation must be accompanied by effective regulation, both through policies with respect to the conditions of use of radio frequencies, as in regulating the use of distribution networks of electricity as a means of transport for communication signal. In this context, the present article deals with the fundamental rules governing the application of PLC technology from the standpoint of the distributors and consumers of electricity, with attention to quality assurance of electrical energy and facility security.

  3. 3D digital image correlation investigation of PLC effect in a new Ni-Co base superalloy

    Science.gov (United States)

    Gao, Y.; Fu, S. H.; Cheng, T.; Huo, X.; Zhang, Q. C.

    2013-06-01

    Repeated plastic instability accompanying serrated yielding in stress-strain curves and localization of deformation is observed during plastic deformation of many metallic alloys when tensile specimens are deformed under certain experimental conditions of temperature, strain rate, and pre-deformation. This phenomenon is referred to as the Portevin- Le Chatelier (PLC) effect. TMW alloy, a newly developed Ni-Co base superalloy for aircraft engine application, also exhibit PLC effect during tensile test at temperatures ranging from 300 ° to 600 °, which are also the temperature range for engine working. In this paper, a 3D digital image correlation (3D DIC) measurement system was established to observe the localization of deformation (PLC band) in a tensile test performed on TMW alloy specimen at temperature of 400 °. The 3D DIC system, with displacement measurement accuracy up to 0.01 pixels and strain measurement accuracy up to 100 μɛ, has a high performance in displacement field calculation with more than 10000 points every second on a 3.1G Hz CPU computer. The test result shows that, the PLC bands are inclined at an angle of about 60° to the tensile axis. Unlike tensile test performed on aluminums alloy, the widths of PLC bands of TMW alloy specimen, ranging from 4 mm to 4.5 mm, are much greater than the specimen thickness (0.25 mm).

  4. Saltwell PIC Skid Programmable Logic Controller (PLC) Software Configuration Management Plan

    International Nuclear Information System (INIS)

    KOCH, M.R.

    1999-01-01

    This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell PIC Skids as required by LMH-PRO-309/Rev. 0, Computer Software Quality Assurance, Section 2.6, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell PIC Skid Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell PIC Skid PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis

  5. The tension of framed membranes from computer simulations

    DEFF Research Database (Denmark)

    Hamkens, Daniel; Jeppesen, Claus; Ipsen, John H.

    2018-01-01

    the membranes display power-law characteristics for the equation of state, while higher tension levels includes both an extended linear (elastic) as well as a highly non-linear stretching regime. For semi-flexible membranes a transition from extended to buckled conformations takes place at negative frame......Abstract.: We have analyzed the behavior of a randomly triangulated, self-avoiding surface model of a flexible, fluid membrane subject to a circular boundary by Wang-Landau Monte Carlo computer simulation techniques. The dependence of the canonical free energy and frame tension on the frame area...... is obtained for flexible membranes. It is shown that for low bending rigidities the framed membrane is only stable above a threshold tension, suggesting a discontinuous transition from the collapsed (branched polymer) state to a finite tension extended state. In a tension range above this threshold tension...

  6. The investigation of minoxidil-induced [Ca2+]i rises and non-Ca2+-triggered cell death in PC3 human prostate cancer cells.

    Science.gov (United States)

    Chen, I-Shu; Chou, Chiang-Ting; Liu, Yuan-Yuarn; Yu, Chia-Cheng; Liang, Wei-Zhe; Kuo, Chun-Chi; Shieh, Pochuen; Kuo, Daih-Huang; Chen, Fu-An; Jan, Chung-Ren

    2017-02-01

    Minoxidil is clinically used to prevent hair loss. However, its effect on Ca 2+ homeostasis in prostate cancer cells is unclear. This study explored the effect of minoxidil on cytosolic-free Ca 2+ levels ([Ca 2+ ] i ) and cell viability in PC3 human prostate cancer cells. Minoxidil at concentrations between 200 and 800 μM evoked [Ca 2+ ] i rises in a concentration-dependent manner. This Ca 2+ signal was inhibited by 60% by removal of extracellular Ca 2+ . Minoxidil-induced Ca 2+ influx was confirmed by Mn 2+ -induced quench of fura-2 fluorescence. Pre-treatment with the protein kinase C (PKC) inhibitor GF109203X, PKC activator phorbol 12-myristate 13 acetate (PMA), nifedipine and SKF96365 inhibited minoxidil-induced Ca 2+ signal in Ca 2+ containing medium by 60%. Treatment with the endoplasmic reticulum Ca 2+ pump inhibitor 2,5-ditert-butylhydroquinone (BHQ) in Ca 2+ -free medium abolished minoxidil-induced [Ca 2+ ] i rises. Conversely, treatment with minoxidil abolished BHQ-induced [Ca 2+ ] i rises. Inhibition of phospholipase C (PLC) with U73122 abolished minoxidil-evoked [Ca 2+ ] i rises. Overnight treatment with minoxidil killed cells at concentrations of 200-600 μM in a concentration-dependent fashion. Chelation of cytosolic Ca 2+ with 1,2-bis(2-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid/AM (BAPTA/AM) did not prevent minoxidil's cytotoxicity. Together, in PC3 cells, minoxidil induced [Ca 2+ ] i rises that involved Ca 2+ entry through PKC-regulated store-operated Ca 2+ channels and PLC-dependent Ca 2+ release from the endoplasmic reticulum. Minoxidil-induced cytotoxicity in a Ca 2+ -independent manner.

  7. 76 FR 78805 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-12-20

    ... Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation... all Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines. This AD results from mandatory... inspection of the FOHE mounts. We did not change the AD based on this comment. Request To Add Requirement To...

  8. 76 FR 68663 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-11-07

    ...-0755; Directorate Identifier 2010-NE-12-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... Rolls-Royce plc, Corporate Communications, P.O. Box 31, Derby, England, DE248BJ; phone: 011-44-1332... date and may amend this proposed AD based on those comments. We will post all comments we receive...

  9. 78 FR 6206 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-01-30

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., RB211-Trent 977-84, RB211-Trent 977B-84 and RB211-Trent 980-84 turbofan engines. This AD requires on...

  10. A combined PLC and CPU approach to multiprocessor control

    International Nuclear Information System (INIS)

    Harris, J.J.; Broesch, J.D.; Coon, R.M.

    1995-10-01

    A sophisticated multiprocessor control system has been developed for use in the E-Power Supply System Integrated Control (EPSSIC) on the DIII-D tokamak. EPSSIC provides control and interlocks for the ohmic heating coil power supply and its associated systems. Of particular interest is the architecture of this system: both a Programmable Logic Controller (PLC) and a Central Processor Unit (CPU) have been combined on a standard VME bus. The PLC and CPU input and output signals are routed through signal conditioning modules, which provide the necessary voltage and ground isolation. Additionally these modules adapt the signal levels to that of the VME I/O boards. One set of I/O signals is shared between the two processors. The resulting multiprocessor system provides a number of advantages: redundant operation for mission critical situations, flexible communications using conventional TCP/IP protocols, the simplicity of ladder logic programming for the majority of the control code, and an easily maintained and expandable non-proprietary system

  11. 76 FR 5467 - Airworthiness Directives; Pilatus Aircraft Ltd. Models PC-6, PC-6-H1, PC-6-H2, PC-6/350, PC-6/350...

    Science.gov (United States)

    2011-02-01

    ...;Prices of new books are listed in the first FEDERAL REGISTER issue of each #0;week. #0; #0; #0; #0;#0..., Fairchild Heli Porter PC-6 airplanes, or Fairchild-Hiller Corporation PC-6 airplanes. Discussion Section... [[Page 5469

  12. 75 FR 45560 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2010-08-03

    ...-0755; Directorate Identifier 2010-NE-12-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... based on engine thrust rating but now based on operating shaft speeds) introduced by Rolls- Royce. The...-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom: Telephone 44 (0) 1332 242424; fax 44 (0) 1332...

  13. 76 FR 72650 - Airworthiness Directives; Rolls-Royce plc (RR) RB211 Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2011-11-25

    ...-0959; Directorate Identifier 2011-NE-25-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone... AD. We will consider all comments received by the closing date and may amend this proposed AD based...

  14. A fast PID controller Design for Modern PLC for Process Control Application

    International Nuclear Information System (INIS)

    Mirza, A.; Nafis, A.; Anees, R.M.; Idris, S.

    2004-01-01

    PID is the most widely used control scheme in the process industry. Pill controllers are utilized for the control of such varied parameters as pressure, flow, temperature, etc. One characteristic of these parameters is that they posses slow dynamics. Most of the available digital controllers can manipulate only a single parameter- multiple controllers are required for control of more than one parameter. The Fast PID Controller for Modem PLC (Programmable Logic Controller) developed by the authors, provides control of several parameters at a time (through a single Pill control element), enhanced programmability including variable sampling period, parameter monitoring and data storage, which may be easily implemented in a PLC. (author)

  15. Biochemical characterization of the tomato phosphatidylinositol-specific phospholipase C (PI-PLC) family and its role in plant immunity

    NARCIS (Netherlands)

    Abd-El-Haliem, Ahmed; Vossen, J.H.; Zeijl, van Arjan; Dezhsetan, Sara; Testerink, Christa; Seidl, M.F.; Beck, Martina; Strutt, James; Robatzek, Silke; Joosten, M.H.A.J.

    2016-01-01

    Plants possess effective mechanisms to quickly respond to biotic and abiotic stresses. The rapid activation of phosphatidylinositol-specific phospholipase C (PLC) enzymes occurs early after the stimulation of plant immune-receptors. Genomes of different plant species encode multiple PLC homologs

  16. Development of Application Programming Tool for Safety Grade PLC (POSAFE-Q)

    International Nuclear Information System (INIS)

    Koo, Kyungmo; You, Byungyong; Kim, Tae-Wook; Cho, Sengjae; Lee, Jin S.

    2006-01-01

    The pSET (POSAFE-Q Software Engineering Tool) is an application programming tool of the POSAFE-Q which is a safety graded programmable logic controller (PLC) developed for the reactor protect system of the nuclear power plant. The pSET provides an integrated development environment (IDE) which includes editors, compiler, simulator, down loader, debugger, and monitor. The pSET supports the IEC61131-3 standard software model and languages such as LD (ladder diagram) and FBD (function block diagram) which are two of the most widely used PLC programming languages in industry fields. The pSET will also support SFC (sequential function chart) language. The pSET is developed as a part of a Korea Nuclear Instrumentation and Control System (KNICS) project

  17. Developing a Novel USB-PLC Controller for a Mechatronics Cloud Laboratory

    Directory of Open Access Journals (Sweden)

    Wen-Jye Shyr

    2013-04-01

    Full Text Available This study proposes the development and implementation of a novel Universal Serial Bus (USB-Programmable Logic Controller (PLC, called a USB-PLC controller, for a mechatronics cloud laboratory. The aim of a mechatronics cloud laboratory is to provide state of the art research quality equipment to students, allowing them to conduct hands-on experiments via the Internet. One objective of the cloud laboratory is to not only provide equipment for conducting set experiments, but also to provide a means for students to access research equipment in order to conduct individual research experiments. The proposed controller for these cloud laboratory experiments has been chosen in order to expose the students to as many different engineering and technology disciplines as possible.

  18. A Cost Effective Solution for Development Environment for Data Acquisition, Monitoring and Simulation of PLC Controlled Applications

    Directory of Open Access Journals (Sweden)

    O. Bjelica

    2014-06-01

    Full Text Available It is very important to test and monitor the operation of Programmable Logic Controller (PLC in real time (online. Nowadays, conventional, but expensive monitoring systems for PLCs, such as Supervisory Control and Data Acquisition (SCADA systems, software and hardware simulators (or debuggers, are widely used. This paper proposes a user friendly and cost-effective development environment for monitoring, data acquisition and online simulation of applications with PLC. The purpose of this solution is to simulate the process which is controlled by the PLC. The performances of the proposed development environment are presented on the examples of washing machine and dishwasher simulators.

  19. An Integrated Software Development Framework for PLC and FPGA based Digital I and Cs

    International Nuclear Information System (INIS)

    Yoo, Jun Beom; Kim, Eui Sub; Lee, Dong Ah; Choi, Jong Gyun

    2014-01-01

    NuDE 2.0 (Nuclear Development Environment) is a model-based software development environment for safety- critical digital systems in nuclear power plants. It makes possible to develop PLC-based systems as well as FPGA-based systems simultaneously from the same requirement or design specifications. The case study showed that the NuDE 2.0 can be adopted as an effective method of bridging the gap between the existing PLC and upcoming FPGA-based developments as well as a means of gaining diversity

  20. An Integrated Software Development Framework for PLC and FPGA based Digital I and Cs

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Jun Beom; Kim, Eui Sub; Lee, Dong Ah [Konkuk University, Seoul (Korea, Republic of); Choi, Jong Gyun [KAERI, Daejeon (Korea, Republic of)

    2014-08-15

    NuDE 2.0 (Nuclear Development Environment) is a model-based software development environment for safety- critical digital systems in nuclear power plants. It makes possible to develop PLC-based systems as well as FPGA-based systems simultaneously from the same requirement or design specifications. The case study showed that the NuDE 2.0 can be adopted as an effective method of bridging the gap between the existing PLC and upcoming FPGA-based developments as well as a means of gaining diversity.

  1. Exploring spatial-temporal dynamics of fire regime features in mainland Spain

    Science.gov (United States)

    Jiménez-Ruano, Adrián; Rodrigues Mimbrero, Marcos; de la Riva Fernández, Juan

    2017-10-01

    This paper explores spatial-temporal dynamics in fire regime features, such as fire frequency, burnt area, large fires and natural- and human-caused fires, as an essential part of fire regime characterization. Changes in fire features are analysed at different spatial - regional and provincial/NUTS3 - levels, together with summer and winter temporal scales, using historical fire data from Spain for the period 1974-2013. Temporal shifts in fire features are investigated by means of change point detection procedures - Pettitt test, AMOC (at most one change), PELT (pruned exact linear time) and BinSeg (binary segmentation) - at a regional level to identify changes in the time series of the features. A trend analysis was conducted using the Mann-Kendall and Sen's slope tests at both the regional and NUTS3 level. Finally, we applied a principal component analysis (PCA) and varimax rotation to trend outputs - mainly Sen's slope values - to summarize overall temporal behaviour and to explore potential links in the evolution of fire features. Our results suggest that most fire features show remarkable shifts between the late 1980s and the first half of the 1990s. Mann-Kendall outputs revealed negative trends in the Mediterranean region. Results from Sen's slope suggest high spatial and intra-annual variability across the study area. Fire activity related to human sources seems to be experiencing an overall decrease in the northwestern provinces, particularly pronounced during summer. Similarly, the Hinterland and the Mediterranean coast are gradually becoming less fire affected. Finally, PCA enabled trends to be synthesized into four main components: winter fire frequency (PC1), summer burnt area (PC2), large fires (PC3) and natural fires (PC4).

  2. PC-AT to gamma camera interface ANUGAMI-S

    International Nuclear Information System (INIS)

    Bhattacharya, Sadhana; Gopalakrishnan, K.R.

    1997-01-01

    PC-AT to gamma camera interface is an image acquisition system used in nuclear medicine centres and hospitals. The interface hardware and acquisition software have been designed and developed to meet most of the routine clinical applications using gamma camera. The state of the art design of the interface provides quality improvement in addition to image acquisition, by applying on-line uniformity correction which is very essential for gamma camera applications in nuclear medicine. The improvement in the quality of the image has been achieved by image acquisition in positionally varying and sliding energy window. It supports all acquisition modes viz. static, dynamic and gated acquisition modes with and without uniformity correction. The user interface provides the acquisition in various user selectable frame sizes, orientation and colour palettes. A complete emulation of camera console has been provided along with persistence scope and acquisition parameter display. It is a universal system which provides a modern, cost effective and easily maintainable solution for interfacing any gamma camera to PC or upgradation of analog gamma camera. (author). 4 refs., 3 figs

  3. Design and development of PLC based offline impedance matching system for ICRH experiment

    International Nuclear Information System (INIS)

    Joshi, Ramesh; Jadav, H.M.; Mali, Aniruddh; Kulkarni, S.V.

    2015-01-01

    Ion Cyclotron Resonance Heating (ICRH) transmission line has two impedance matching networks, one for offline matching which has been employed before experimental shot. Another is online impedance matching which has been employed during experimental shot. Offline matching network consists of two static stubs, coarse tuner and coarse phase shifter identical in both transmission lines. There are motorized arrangement installed in each stubs and phase shifters. Both stubs are being used to vary transmission line length. Phase shifter is used to match the frequency of generated RF power. Programmable Logic Controller (PLC) based automation and control technique has been designed and developed for the system. Offline matching should be operated below 1 kHz frequency in order to move stepper motors. Program generates required square pulses which employed to motor controller to move either in upward or downward direction. In existing system this operation has been carried out using VME. To reduce the load on VME, PLC based system has been designed and integrated with main DAC system. WinCC software has been used (as SCADA/HMI) to develop front end GUI which communicates with OPC server. Further, OPC communicates with PLC for control of motorized arrangement. This paper describes technical details,design and development of PLC based offline matching system using WinCC as user interface. The communication between WinCC application and hardware devices was realized by OPC technique. The developed system has friendly graphical user interface, high-level automation and comprehensive function such as experimental process control. The system was proved to be reliable and accurate in practical application. (author)

  4. Quantitative rotating frame relaxometry methods in MRI.

    Science.gov (United States)

    Gilani, Irtiza Ali; Sepponen, Raimo

    2016-06-01

    Macromolecular degeneration and biochemical changes in tissue can be quantified using rotating frame relaxometry in MRI. It has been shown in several studies that the rotating frame longitudinal relaxation rate constant (R1ρ ) and the rotating frame transverse relaxation rate constant (R2ρ ) are sensitive biomarkers of phenomena at the cellular level. In this comprehensive review, existing MRI methods for probing the biophysical mechanisms that affect the rotating frame relaxation rates of the tissue (i.e. R1ρ and R2ρ ) are presented. Long acquisition times and high radiofrequency (RF) energy deposition into tissue during the process of spin-locking in rotating frame relaxometry are the major barriers to the establishment of these relaxation contrasts at high magnetic fields. Therefore, clinical applications of R1ρ and R2ρ MRI using on- or off-resonance RF excitation methods remain challenging. Accordingly, this review describes the theoretical and experimental approaches to the design of hard RF pulse cluster- and adiabatic RF pulse-based excitation schemes for accurate and precise measurements of R1ρ and R2ρ . The merits and drawbacks of different MRI acquisition strategies for quantitative relaxation rate measurement in the rotating frame regime are reviewed. In addition, this review summarizes current clinical applications of rotating frame MRI sequences. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  5. On the Dynamic Nature of Performance Management Regimes

    DEFF Research Database (Denmark)

    Kristiansen, Mads Bøge; Dahler-Larsen, Peter; Ghin, Eva Moll

    2018-01-01

    The ambition of this article is to gain a better understanding of the endogenous dynamics of performance management regimes. Based on a review of the literature, we develop a framework that enables us to grasp dimensions and mechanisms of escalation. Hereafter, we demonstrate the use of our frame...

  6. Experimental Study of 6LoPLC for Home Energy Management Systems

    Directory of Open Access Journals (Sweden)

    Augustine Ikpehai

    2016-12-01

    Full Text Available Ubiquitous connectivity is already transforming residential dwellings into smart homes. As citizens continue to embrace the smart home paradigm, a new generation of low-rate and low-power communication systems is required to leverage the mass market presented by energy management in homes. Although Power Line Communication (PLC technology has evolved in the last decade, the adaptation of PLC for constrained networks is not fully charted. By adapting some features of IEEE 802.15.4 and IPv6 over Low-power Wireless Personal Area Network (6LoWPAN into power lines, this paper demonstrates a low-rate, low-power PLC system over the IPv6 network (referred to as 6LoPLC, for Home Energy Management System (HEMS applications. The overall idea is to provide a framework for assessing various scenarios that cannot be easily investigated with the limited number of evaluation hardware available. In this respect, a network model is developed in NS-3 (Version 21 to measure several important characteristics of the designed system and then validated with experimental results obtained using the Hanadu evaluation kits. Following the good agreement between the two, the NS-3 model is utilised to investigate more complex scenarios and various use-cases, such as the effects of impulsive noise, the number of nodes and packet size on the latency and Bit Error Rate (BER performances. We further demonstrate that for different network and application configurations, optimal data sizes exist. For instance, the results reveal that in order to guarantee 99% system reliability, the HEMS application data must not exceed 64 bytes. Finally, it is shown that with impulsive noise in a HEMS network comprising 50 appliances, provided the size of the payload does not exceed 64 bytes, monitoring and control applications incur a maximum latency of 238.117 ms and 248.959 ms, respectively; both of which are within acceptable limits.

  7. Prospective radiological dose assessment. Amersham plc (Amersham site) variation application December 1998

    International Nuclear Information System (INIS)

    Allott, R.

    2001-01-01

    Amersham plc (previously Nycomed-Amersham plc) submitted an application to the Environment Agency in December 1998 for a variation to their radioactive waste discharge authorisations granted under the Radioactive Substances Act 1993. The application requested a reduction in the discharge limits for certain radionuclides and no change for the remaining radionuclides. Amersham plc undertook a further review of their discharge requirements and submitted a new assessment for revised limits in January 2001. This report provides an assessment of the radiological implications of discharges at these revised limits requested by Amersham plc and the limits proposed by the Agency. It has been prepared by the National Compliance Assessment Service at the request of Thames Region to support their determination of the application. Four candidate critical groups were identified who could be exposed to discharges from the Amersham site: 1) Sewage workers at the Maple Lodge sewage works who might be exposed to external radiation from discharges contained within sewage and inadvertently inhale or ingest sewage. 2) Anglers on the Grand Union Canal who eat a small proportion of their annual catch of freshwater fish, who drink water abstracted solely from the River Colne and eat vegetables irrigated by water from the canal. 3) Persons living closest to site who eat locally produced food. 4) Dog walkers living near to site who eat locally produced food. For continuous discharges at the Agency's proposed annual limits, the highest dose of 160 μSv/y is predicted to be received by infants who live closest to the site and eat locally produced food. Therefore, this has been identified as the critical group. Children and adults living at the same location and eating locally produced food receive doses of 140 μSv/y and 130 μSv/y respectively. The critical group dose is less than the source constraint of 300 μSv/y. The dose is dominated by direct radiation from the site (110 μSv/y) and the

  8. 77 FR 21588 - Hart and Cooley, Inc., A Subsidiary of Tomkins, PLC Including On-Site Leased Workers from...

    Science.gov (United States)

    2012-04-10

    ... Subsidiary of Tomkins, PLC Including On- Site Leased Workers from Reliable, Masiello Employment Services..., applicable to workers of Hart and Cooley, Inc., a subsidiary of Tomkins, PLC, including on-site leased... workers. Based on these findings, the Department is amending this certification to include workers leased...

  9. 75 FR 34172 - Rexam Closure Systems, Inc., a Subsidiary of Rexam PLC, Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-06-16

    ... Illinois Manufacturing, Hamlet, NC; Amended Certification Regarding Eligibility To Apply for Worker... PLC, Hamlet, North Carolina. The notice was published in the Federal Register on April 23, 2010 (75 FR... at the Hamlet, North Carolina location of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC. The...

  10. Knowledge-based engineering of a PLC controlled telescope

    Science.gov (United States)

    Pessemier, Wim; Raskin, Gert; Saey, Philippe; Van Winckel, Hans; Deconinck, Geert

    2016-08-01

    As the new control system of the Mercator Telescope is being finalized, we can review some technologies and design methodologies that are advantageous, despite their relative uncommonness in astronomical instrumentation. Particular for the Mercator Telescope is that it is controlled by a single high-end soft-PLC (Programmable Logic Controller). Using off-the-shelf components only, our distributed embedded system controls all subsystems of the telescope such as the pneumatic primary mirror support, the hydrostatic bearing, the telescope axes, the dome, the safety system, and so on. We show how real-time application logic can be written conveniently in typical PLC languages (IEC 61131-3) and in C++ (to implement the pointing kernel) using the commercial TwinCAT 3 programming environment. This software processes the inputs and outputs of the distributed system in real-time via an observatory-wide EtherCAT network, which is synchronized with high precision to an IEEE 1588 (PTP, Precision Time Protocol) time reference clock. Taking full advantage of the ability of soft-PLCs to run both real-time and non real-time software, the same device also hosts the most important user interfaces (HMIs or Human Machine Interfaces) and communication servers (OPC UA for process data, FTP for XML configuration data, and VNC for remote control). To manage the complexity of the system and to streamline the development process, we show how most of the software, electronics and systems engineering aspects of the control system have been modeled as a set of scripts written in a Domain Specific Language (DSL). When executed, these scripts populate a Knowledge Base (KB) which can be queried to retrieve specific information. By feeding the results of those queries to a template system, we were able to generate very detailed "browsable" web-based documentation about the system, but also PLC software code, Python client code, model verification reports, etc. The aim of this paper is to

  11. Glycosaminoglycan composition of PC12 pheochromocytoma cells: a comparison with PC12D cells, a new subline of PC12 cells

    Energy Technology Data Exchange (ETDEWEB)

    Katoh-Semba, R.; Oohira, A.; Sano, M.; Watanabe, K.; Kitajima, S.; Kashiwamata, S.

    1989-03-01

    PC12D cells, a new subline of conventional PC12 cells, respond not only to nerve growth factor but also to cyclic AMP by extending their neurites. These cells are flat in shape and are similar in appearance to PC12 cells that have been treated with nerve growth factor for a few days. In both cell lines, we have characterized the glycosaminoglycans, the polysaccharide moieties of proteoglycans, which are believed to play an important role in cell adhesion and in cell morphology. Under the present culture conditions, only chondroitin sulfate was detected in the media from PC12 and PC12D cells, whereas both chondroitin sulfate and heparan sulfate were found in the cell layers. The levels of cell-associated heparan sulfate and chondroitin sulfate were about twofold and fourfold higher in PC12D cells than in PC12 cells, respectively. Compared to PC12 cells, the amounts of (/sup 35/S)sulfate incorporated for 48 h into chondroitin sulfate were twofold lower but those into heparan sulfate were 35% higher in PC12D cells. The amount of chondroitin sulfate released by PC12D cells into the medium was about a half of that released by PC12 cells. The ratio of (/sup 35/S)sulfate-labeled heparan sulfate to chondroitin sulfate was 6.2 in PC12D cells and 2.2 in PC12 cells. These results suggest that there may be some correlation between the increase in content of glycosaminoglycans and the change in cell morphology, which is followed by neurite outgrowth.

  12. Design and Implementation of an over Current Protection Laboratory for Electrical Power Transmission Systems Based on PLC Techniques

    Directory of Open Access Journals (Sweden)

    Hassaan Th. H. Thabet

    2018-01-01

    Full Text Available This paper describes a modern approach for the protection of transmission lines to ensure theirsafety against the faults occurred in power systems. Our approach uses a Programmable LogicController (PLC to realize a transmission line as an over current protection relay. A conditioningcircuit was designed, implemented and tested to collect data obtained from Hall Effect sensors which convert them to suitable analog values compatible with PLC's inputs. Results obtained by our PLC control system are very similar to those obtained by the conventional relays but more efficient. An Automatic Reclosing System (ARS for remote faults is also included in this approach. Our PLC control system and its algorithm are illustrated in this paper also. This approach is designed to be used in electrical networks laboratories as an educational unit in electrical departments of engineering collages and technical institutes; it can be used also in real power systems through suitable interfacing facilities.

  13. The new control system of HLS linac and transport line

    International Nuclear Information System (INIS)

    Liu Gongfa; Li Weimin; Li Jingyi; Li Chuan; Cheng Liping; Bao Xun; Wang Jigang; Xuan Ke

    2005-01-01

    The new linac and transport line control system of Hefei Light Source (HLS) is a distributed control system based on EPICS (Experimental Physics and Industrial Control System). Industrial PC (IPC) is widely used as not only Input/Output Controller (IOC) but also device controller. Besides industrial PC, PLC and microcontroller are also used as device controllers. The software for industrial PC based device controller is developed based on VxWorks real-time operating system. The software for PLC and microcontroller are written with ladder software package and assemble language, respectively. PC with Linux and SUN workstation with Solaris are used as operator interfaces (OPI). High level control is made up of some EPICS tools and Tcl/Tk scripts. (authors)

  14. VIDEO-PC, SVGA Routines for FORTRAN on PC

    International Nuclear Information System (INIS)

    1994-01-01

    1 - Description of program or function: These primitives are the lowest level routines needed to perform super VGA graphics on a PC. A sample main program is included that exercises the primitives. Both Lahey and Microsoft FORTRAN's have graphics libraries. However, the libraries do not support 256 color graphics at resolutions greater than 320x200. The primitives bypass these libraries while still conforming to standard usage of BIOS. The supported graphics modes depend upon the PC graphics card and its memory. Super VGA resolutions of 640x480 and 800x600 have been tested on an ATI VGA Wonder card with 512 K memory and on several 80486 PC's (unknown manufacturers) at retail stores. 2 - Method of solution: Both Lahey and Microsoft primitives depend upon sending the correct parameters to the PC BIOS (basic input output system) as discussed in the references. 3 - Restrictions on the complexity of the problem: The primitives were developed for 256 color VGA applications. It is known, for instance, that some CGA and 16 color VGA video modes will not operate correctly using these primitives. Potential users should try the test program on their PC/video card combination to determine applicability

  15. SwissProt search result: AK119633 [KOME

    Lifescience Database Archive (English)

    Full Text Available AK119633 002-130-E12 (P15713) Non-hemolytic phospholipase C precursor (EC 3.1.4.3) (PLC-N) (Phosphatidylchol...ine cholinephosphohydrolase) (Phosphatidylcholine-hydrolyzing phospholipase C) (PC-PLC) PHLN_PSEAE 1e-13 ...

  16. SwissProt search result: AK101291 [KOME

    Lifescience Database Archive (English)

    Full Text Available AK101291 J033033G16 (P15713) Non-hemolytic phospholipase C precursor (EC 3.1.4.3) (PLC-N) (Phosphatidylcholi...ne cholinephosphohydrolase) (Phosphatidylcholine-hydrolyzing phospholipase C) (PC-PLC) PHLN_PSEAE 1e-13 ...

  17. SwissProt search result: AK243286 [KOME

    Lifescience Database Archive (English)

    Full Text Available AK243286 J100052F22 (P15713) Non-hemolytic phospholipase C precursor (EC 3.1.4.3) (PLC-N) (Phosphatidylcholi...ne cholinephosphohydrolase) (Phosphatidylcholine-hydrolyzing phospholipase C) (PC-PLC) PHLN_PSEAE 2e-16 ...

  18. Slovak Electric, Plc., 1997

    International Nuclear Information System (INIS)

    1997-06-01

    Slovenske elektrarne, a.s. (Slovak Electric, Plc.) was established on November 1, 1994 as one entity among new entities created as successors to the former Slovensky energeticky podnik. The subject activity is the generation of electric power, operation of transmission 220 kV and 400 kV systems, transit, import, export, and sales of electric power. Besides these activities the company deals with generation, distribution, and sales of heat. The company operates one nuclear power station, three thermal power plants, and thirty hydro power plants. One nuclear Power plant is under construction (state up tu June 1997). On this CD ROM next chapters are presented: (1) The structure of the company; (2) The production Units; (3) The economic power of the company; (4) The operation culture of the company; (5) The strategic plans of the company

  19. Biomimicry 1: PC.

    Science.gov (United States)

    Cumberland, D C; Gunn, J; Malik, N; Holt, C M

    1998-01-01

    The surface properties of stents can be modified by coating them, for example with a polymer. Phosphorylcoline (PC) is the major component of the outer layer of the cell membrane. The haemo- and biocompatibility of a PC-containing polymer is thus based on biomimicry, and has been confirmed by several experiments showing much reduced thrombogenicity of PC-coated surfaces, and porcine coronary artery implants showing no sign of adverse effect. Clinical experience with the PC-coated BiodivYsio appears favourable. The PC coating can be tailored for take up and controlled elution of various drugs for stent-based local delivery, a property which is being actively explored.

  20. Operating experiences with programmable logic controller (PLC) system of Indian Pressurised Heavy Water Reactors (PHWR)

    International Nuclear Information System (INIS)

    Ughade, A.V.; Singh, Ranjeet; Bhattacharya, P.K.; Kulkarni, R.K.; Chandra, Umesh

    2005-01-01

    PLC system was introduced for the first time in Kaiga-1,2 and RAPS-3,4 Nuclear Power Plants (NPPs) for Station Logic Control of Non Safety Related (NSR) and Safety related (SR) systems. However, the safety system logics are still relay based. The experience on the deployment of PLC system, which is computer-based, has brought out various implementation issues. This paper give details of such experiences, the solutions emerged and applied for plants under operation/construction. (author)

  1. Frames and semi-frames

    International Nuclear Information System (INIS)

    Antoine, Jean-Pierre; Balazs, Peter

    2011-01-01

    Loosely speaking, a semi-frame is a generalized frame for which one of the frame bounds is absent. More precisely, given a total sequence in a Hilbert space, we speak of an upper (resp. lower) semi-frame if only the upper (resp. lower) frame bound is valid. Equivalently, for an upper semi-frame, the frame operator is bounded, but has an unbounded inverse, whereas a lower semi-frame has an unbounded frame operator, with a bounded inverse. We study mostly upper semi-frames, both in the continuous and discrete case, and give some remarks for the dual situation. In particular, we show that reconstruction is still possible in certain cases.

  2. Design and Implementation of PLC-Based Automatic Sun tracking System for Parabolic Trough Solar Concentrator

    Directory of Open Access Journals (Sweden)

    Wang Jinping

    2016-01-01

    Full Text Available A sun-tracking system for parabolic trough solar concentrators (PTCs is a control system used to orient the concentrator toward the sun always, so that the maximum energy can be collected. The work presented here is a design and development of PLC based sun tracking control system for PTC. Sun tracking control system consists of a Programmable Logic Controller (PLC and a single axis hydraulic drives tracking control system. Hydraulic drives and the necessary tracking angle algorithm have been designed and developed to perform the technical tasks. A PLC unit was employed to control and monitor the mechanical movement of the PTC and to collect and store data related to the tracking angle of PTC. It is found that the tracking error of the system is less than 0.6°. Field experience shows that tracking algorithm act stable and reliable and suit for PTCs.

  3. PLC Based Automatic Multistoried Car Parking System

    OpenAIRE

    Swanand S .Vaze; Rohan S. Mithari

    2014-01-01

    This project work presents the study and design of PLC based Automatic Multistoried Car Parking System. Multistoried car parking is an arrangement which is used to park a large number of vehicles in least possible place. For making this arrangement in a real plan very high technological instruments are required. In this project a prototype of such a model is made. This prototype model is made for accommodating twelve cars at a time. Availability of the space for parking is detecte...

  4. International Food Regime

    Directory of Open Access Journals (Sweden)

    A. V. Malov

    2018-01-01

    Full Text Available The review article reveals the content of the concept of Food Regime, which is little-known in the Russian academic reference. The author monitored and codified the semantic dynamic of the terminological unit from its original interpretations to modern formulations based on the retrospective analysis. The rehabilitation of the academic merits of D. Puchala and R. Hopkins — authors who used the concept Food Regime for a few years before its universally recognized origin and official scientific debut, was accomplished with help of historical and comparative methods. The author implemented the method of ascension from the abstract to the concrete to demonstrating the classification of Food Regimes compiled on the basis of geopolitical interests in the sphere of international production, consumption, and distribution of foodstuffs. The characteristic features of historically formed Food Regime were described in the chronological order, as well as modern tendencies possessing reformist potential were identified. In particular, it has been established that the idea of Food Sovereignty (which is an alternative to the modern Corporate Food Regime is the subject for acute academic disputes. The discussion between P. McMichael P. and H. Bernstein devoted to the “peasant question” — mobilization frame of the Food Sovereignty strategy was analyzed using the secondary data processing method. Due to the critical analysis, the author comes to the conclusion that it is necessary to follow the principles of the Food Sovereignty strategy to prevent the catastrophic prospects associated with ecosystem degradation, accelerated erosion of soils, the complete disappearance of biodiversity and corporate autoc racy successfully. The author is convinced that the idea of Food Sovereignty can ward off energetic liberalization of nature, intensive privatization of life and rapid monetization of unconditioned human reflexes.

  5. Effects of 5-fluorouracil on biological characteristics and drug resistance mechanisms of liver cancer cell line PLC/RAF/5

    Directory of Open Access Journals (Sweden)

    CHENG Kangwen

    2015-09-01

    Full Text Available ObjectiveTo study the changes in biological characteristics of a liver cancer cell line PLC/RAF/5 after repeated exposure to a chemotherapy drug, 5-fluorouraci (5-FU, and to investigate the relationship between drug-resistant liver cancer cells and liver cancer stem cells. MethodsA low concentration of 5-FU (1 μg/ml was used to treat the human liver cancer cell line PLC/RAF/5 repeatedly to establish the PLC/RAF/5/5-FU cell line. Morphological differences between the two types of cells were observed. The inhibitory effects of different concentrations of 5-FU (0, 0.25, 0.5, 1, 1.5, and 2 μg/ml on the proliferation of the two types of cells were determined using the CCK-8 assay. Apoptosis of the two types of cells after exposure to different concentrations of 5-FU (0.5, 1, and 2 μg/ml for 48 h was analyzed using flow cytometry. The proportions of side population cells in both types of cells were measured using flow cytometry. The colony-forming ability was compared between the two types of cells by the plate colony-forming assay. The expression of Bax, Bcl-2, ABCG2, and FoxM1 proteins in both types of cells was examined by Western blot. Between-group comparison was performed by t test. ResultsThe PLC/RAF/5/5-FU cell line was successfully established using the chemotherapy drug 5-FU. Compared with the PLC/RAF/5 cells, the PLC/RAF/5/5-FU cells had a larger volume, fewer protrusions, a changed shape of a long shuttle, and enhanced refractivity. Moreover, compared with the parent cells, the PLC/RAF/5/5-FU cells had a significantly lower sensitivity to the inhibitory effect of 5-FU on proliferation, a significantly lower proportion of cells at the G0/G1 phase of the cell cycle, significantly higher proportions of cells at the S and G2/M phases, significantly higher resistance to apoptosis, a significantly higher proportion of side population cells, and significantly enhanced proliferation (P<0.05. According to the results of Western blot assay, the

  6. 75 FR 17630 - Airworthiness Directives; Rolls-Royce plc RB211 Trent 700 and Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2010-04-07

    ...-0364; Directorate Identifier 2009-NE-27-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc... based on those comments. We will post all comments we receive, without change, to http://www.regulations... Service Information Rolls-Royce plc has issued Alert Service Bulletin RB.211-72-AG086, dated December 4...

  7. Modeling of Hydration, Compressive Strength, and Carbonation of Portland-Limestone Cement (PLC Concrete

    Directory of Open Access Journals (Sweden)

    Xiao-Yong Wang

    2017-01-01

    Full Text Available Limestone is widely used in the construction industry to produce Portland limestone cement (PLC concrete. Systematic evaluations of hydration kinetics, compressive strength development, and carbonation resistance are crucial for the rational use of limestone. This study presents a hydration-based model for evaluating the influences of limestone on the strength and carbonation of concrete. First, the hydration model analyzes the dilution effect and the nucleation effect of limestone during the hydration of cement. The degree of cement hydration is calculated by considering concrete mixing proportions, binder properties, and curing conditions. Second, by using the gel–space ratio, the compressive strength of PLC concrete is evaluated. The interactions among water-to-binder ratio, limestone replacement ratio, and strength development are highlighted. Third, the carbonate material contents and porosity are calculated from the hydration model and are used as input parameters for the carbonation model. By considering concrete microstructures and environmental conditions, the carbon dioxide diffusivity and carbonation depth of PLC concrete are evaluated. The proposed model has been determined to be valid for concrete with various water-to-binder ratios, limestone contents, and curing periods.

  8. 78 FR 5126 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-01-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. This AD requires replacement of the fuel oil heat exchanger (FOHE). This AD was prompted...-84 turbofan engines with a fuel oil heat exchanger (FOHE), part number 47111-1241, installed. (d...

  9. Exploring spatial–temporal dynamics of fire regime features in mainland Spain

    Directory of Open Access Journals (Sweden)

    A. Jiménez-Ruano

    2017-10-01

    Full Text Available This paper explores spatial–temporal dynamics in fire regime features, such as fire frequency, burnt area, large fires and natural- and human-caused fires, as an essential part of fire regime characterization. Changes in fire features are analysed at different spatial – regional and provincial/NUTS3 – levels, together with summer and winter temporal scales, using historical fire data from Spain for the period 1974–2013. Temporal shifts in fire features are investigated by means of change point detection procedures – Pettitt test, AMOC (at most one change, PELT (pruned exact linear time and BinSeg (binary segmentation – at a regional level to identify changes in the time series of the features. A trend analysis was conducted using the Mann–Kendall and Sen's slope tests at both the regional and NUTS3 level. Finally, we applied a principal component analysis (PCA and varimax rotation to trend outputs – mainly Sen's slope values – to summarize overall temporal behaviour and to explore potential links in the evolution of fire features. Our results suggest that most fire features show remarkable shifts between the late 1980s and the first half of the 1990s. Mann–Kendall outputs revealed negative trends in the Mediterranean region. Results from Sen's slope suggest high spatial and intra-annual variability across the study area. Fire activity related to human sources seems to be experiencing an overall decrease in the northwestern provinces, particularly pronounced during summer. Similarly, the Hinterland and the Mediterranean coast are gradually becoming less fire affected. Finally, PCA enabled trends to be synthesized into four main components: winter fire frequency (PC1, summer burnt area (PC2, large fires (PC3 and natural fires (PC4.

  10. Comportamiento de la Tecnología PLC en la Red Eléctrica

    OpenAIRE

    García Guibout, J.; García Garino, Carlos; Fusario, Rubén J.; Castro Lechtaler, Antonio; Sevilla, Guillermo

    2007-01-01

    La tecnología PLC1 - PowerLine Communications- está referida a la transmisión de datos utilizando la red eléctrica, tanto domiciliaria, como la red de distribución de baja tensión. Dependiendo del tipo de red que se utilice como soporte esta tecnología se divide en PLC indoor y outdoor. La primera se refiere a la utilización de la red domiciliaria y utiliza las frecuencias más altas de 5 MHz a 30 ó 40 MHz. La segunda, outdoor, usa la red de distribución y las frecuencias bajas de 1 MHz a 5 ó ...

  11. PLC based automatic control of pasteurize mix in ice cream production

    Science.gov (United States)

    Yao, Xudong; Liang, Kai

    2013-03-01

    This paper describes the automatic control device of pasteurized mix in the ice cream production process.We design a scheme of control system using FBD program language and develop the programmer in the STEP 7-Micro/WIN software, check for any bugs before downloading into PLC .These developed devices will able to provide flexibility and accuracy to control the step of pasteurized mix. The operator just Input the duration and temperature of pasteurized mix through control panel. All the steps will finish automatically without any intervention in a preprogrammed sequence stored in programmable logic controller (PLC). With the help of this equipment we not only can control the quality of ice cream for various conditions, but also can simplify the production process. This control system is inexpensive and can be widely used in ice cream production industry.

  12. Relativistic treatment of Raman free-electro laser in beam frame

    International Nuclear Information System (INIS)

    Korbacheh, A.; Maraghechi, B.; Aghahosseni, H.

    2004-01-01

    A relativistic theory for Raman backscattering in the beam frame of electrons is used to find the growth rate of free- electron laser in Raman regime. The electromagnetic effects of the space-charge wave are taken into account by using the electrostatic approximation in the beam frame. The wiggler effects on the linear dispersion relations of the space- charge wave and radiation are included in the analysis. A numerical computation is conducted to compare the growth rate of the excited waves with nonrelativistic treatment

  13. 78 FR 70487 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-11-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. This AD requires removal of certain high-pressure (HP) and intermediate-pressure (IP..., RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines with turbine disc part numbers (P/Ns) and...

  14. 78 FR 68360 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-11-14

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... turbofan engines. The AD number is incorrect in the Regulatory text. This document corrects that error. In... turbofan engines. As published, the AD number 2013-19-17 under Sec. 39.13 [Amended], is incorrect. No other...

  15. 78 FR 61171 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-10-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) RB211-535E4-B-37 series turbofan engines. This AD requires removal of affected parts using a...-B-37 series turbofan engines. (d) Unsafe Condition This AD was prompted by recalculating the lives...

  16. Methods of Certification tests PLC-Networks in Compliance Safety Information

    Directory of Open Access Journals (Sweden)

    A. A. Balaev

    2011-12-01

    Full Text Available The aim of this research was description of the methodology of the audit plc-network to meet the requirements of information security. The technique is based on the provisions of the guidance documents and model FSTEC Russia test object methods of information on safety information.

  17. Dynamics of plc gene transcription and α-toxin production during growth of Clostridium perfringens strains with contrasting α-toxin production

    DEFF Research Database (Denmark)

    Abildgaard, Lone; Schramm, Andreas; Rudi, Knut

    2009-01-01

    The aim of the present study was to investigate transcription dynamics of the α-toxin-encoding plc gene relative to two housekeeping genes (gyrA and rplL) in batch cultures of three Clostridium perfringens strains with low, intermediate, and high levels of α-toxin production, respectively. The plc...... transcript level was always low in the low α-toxin producing strain. For the two other strains, plc transcription showed an inducible pattern and reached a maximum level in the late exponential growth phase. The transcription levels were however inversely correlated to α-toxin production for the two strains....... We propose that this discrepancy is due to differences in plc translation rates between the strains and that strain-specific translational rates therefore must be determined before α-toxin production can be extrapolated from transcript levels in C. perfringens....

  18. Cheetah: A high frame rate, high resolution SWIR image camera

    Science.gov (United States)

    Neys, Joel; Bentell, Jonas; O'Grady, Matt; Vermeiren, Jan; Colin, Thierry; Hooylaerts, Peter; Grietens, Bob

    2008-10-01

    A high resolution, high frame rate InGaAs based image sensor and associated camera has been developed. The sensor and the camera are capable of recording and delivering more than 1700 full 640x512pixel frames per second. The FPA utilizes a low lag CTIA current integrator in each pixel, enabling integration times shorter than one microsecond. On-chip logics allows for four different sub windows to be read out simultaneously at even higher rates. The spectral sensitivity of the FPA is situated in the SWIR range [0.9-1.7 μm] and can be further extended into the Visible and NIR range. The Cheetah camera has max 16 GB of on-board memory to store the acquired images and transfer the data over a Gigabit Ethernet connection to the PC. The camera is also equipped with a full CameralinkTM interface to directly stream the data to a frame grabber or dedicated image processing unit. The Cheetah camera is completely under software control.

  19. Drosophila fatty acid taste signals through the PLC pathway in sugar-sensing neurons.

    Directory of Open Access Journals (Sweden)

    Pavel Masek

    Full Text Available Taste is the primary sensory system for detecting food quality and palatability. Drosophila detects five distinct taste modalities that include sweet, bitter, salt, water, and the taste of carbonation. Of these, sweet-sensing neurons appear to have utility for the detection of nutritionally rich food while bitter-sensing neurons signal toxicity and confer repulsion. Growing evidence in mammals suggests that taste for fatty acids (FAs signals the presence of dietary lipids and promotes feeding. While flies appear to be attracted to fatty acids, the neural basis for fatty acid detection and attraction are unclear. Here, we demonstrate that a range of FAs are detected by the fly gustatory system and elicit a robust feeding response. Flies lacking olfactory organs respond robustly to FAs, confirming that FA attraction is mediated through the gustatory system. Furthermore, flies detect FAs independent of pH, suggesting the molecular basis for FA taste is not due to acidity. We show that low and medium concentrations of FAs serve as an appetitive signal and they are detected exclusively through the same subset of neurons that sense appetitive sweet substances, including most sugars. In mammals, taste perception of sweet and bitter substances is dependent on phospholipase C (PLC signaling in specialized taste buds. We find that flies mutant for norpA, a Drosophila ortholog of PLC, fail to respond to FAs. Intriguingly, norpA mutants respond normally to other tastants, including sucrose and yeast. The defect of norpA mutants can be rescued by selectively restoring norpA expression in sweet-sensing neurons, corroborating that FAs signal through sweet-sensing neurons, and suggesting PLC signaling in the gustatory system is specifically involved in FA taste. Taken together, these findings reveal that PLC function in Drosophila sweet-sensing neurons is a conserved molecular signaling pathway that confers attraction to fatty acids.

  20. Saltwell Leak Detector Station Programmable Logic Controller (PLC) Software Configuration Management Plan (SCMP)

    International Nuclear Information System (INIS)

    WHITE, K.A.

    2000-01-01

    This document provides the procedures and guidelines necessary for computer software configuration management activities during the operation and maintenance phases of the Saltwell Leak Detector Stations as required by HNF-PRO-309/Rev.1, Computer Software Quality Assurance, Section 2.4, Software Configuration Management. The software configuration management plan (SCMP) integrates technical and administrative controls to establish and maintain technical consistency among requirements, physical configuration, and documentation for the Saltwell Leak Detector Station Programmable Logic Controller (PLC) software during the Hanford application, operations and maintenance. This SCMP establishes the Saltwell Leak Detector Station PLC Software Baseline, status changes to that baseline, and ensures that software meets design and operational requirements and is tested in accordance with their design basis

  1. Variance in total levels of phospholipase C zeta (PLC-ζ) in human sperm may limit the applicability of quantitative immunofluorescent analysis as a diagnostic indicator of oocyte activation capability.

    Science.gov (United States)

    Kashir, Junaid; Jones, Celine; Mounce, Ginny; Ramadan, Walaa M; Lemmon, Bernadette; Heindryckx, Bjorn; de Sutter, Petra; Parrington, John; Turner, Karen; Child, Tim; McVeigh, Enda; Coward, Kevin

    2013-01-01

    To examine whether similar levels of phospholipase C zeta (PLC-ζ) protein are present in sperm from men whose ejaculates resulted in normal oocyte activation, and to examine whether a predominant pattern of PLC-ζ localization is linked to normal oocyte activation ability. Laboratory study. University laboratory. Control subjects (men with proven oocyte activation capacity; n = 16) and men whose sperm resulted in recurrent intracytoplasmic sperm injection failure (oocyte activation deficient [OAD]; n = 5). Quantitative immunofluorescent analysis of PLC-ζ protein in human sperm. Total levels of PLC-ζ fluorescence, proportions of sperm exhibiting PLC-ζ immunoreactivity, and proportions of PLC-ζ localization patterns in sperm from control and OAD men. Sperm from control subjects presented a significantly higher proportion of sperm exhibiting PLC-ζ immunofluorescence compared with infertile men diagnosed with OAD (82.6% and 27.4%, respectively). Total levels of PLC-ζ in sperm from individual control and OAD patients exhibited significant variance, with sperm from 10 out of 16 (62.5%) exhibiting levels similar to OAD samples. Predominant PLC-ζ localization patterns varied between control and OAD samples with no predictable or consistent pattern. The results indicate that sperm from control men exhibited significant variance in total levels of PLC-ζ protein, as well as significant variance in the predominant localization pattern. Such variance may hinder the diagnostic application of quantitative PLC-ζ immunofluorescent analysis. Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Ceramide-Enriched Membrane Domains in Red Blood Cells and the Mechanism ofSphingomyelinase-Induced Hot-Cold Hemolysis

    DEFF Research Database (Denmark)

    Montes, Ruth; Lopez, David; Sot, Jesus

    2008-01-01

    Hot-cold hemolysis is the phenomenon whereby red blood cells, preincubated at 37 °C in the presence of certain agents, undergo rapid hemolysis when transferred to 4 °C. The mechanism of this phenomenon is not understood. PlcHR2, a phospholipase C/sphingomyelinase from Pseudomonas aeruginosa......) but also in goat erythrocytes, which lack PC. However, in horse erythrocytes, with a large proportion of PC and almost no SM, hot-cold hemolysis induced by PlcHR2 is not observed. Fluorescence microscopy observations confirm the formation of ceramide-enriched domains as a result of PlcHR2 activity. After......-cold hemolysis. Differential scanning calorimetry of erytrocyte membranes treated with PlcHR2 demonstrates the presence of ceramide-rich domains that are rigid at 4 °C but fluid at 37 °C. Ceramidase treatment causes the disapperance of the calorimetric signal assigned to ceramide-rich domains. Finally...

  3. 78 FR 20509 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-04-05

    ... Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed rulemaking...) RB211-535E4-B-37 series turbofan engines. This proposed AD was prompted by recalculating the life of.... (c) Applicability This AD applies to Rolls-Royce plc (RR) RB211-535E4-B-37 series turbofan engines...

  4. 77 FR 39157 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-07-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-84, and 980-84 turbofan engines. That AD currently requires inspecting the intermediate-pressure (IP... RR model RB211-Trent 970-84, 970B-84, 972-84, 972B-84, 977-84, 977B-84, and 980-84 turbofan engines...

  5. Performance Evaluation of CE-OFDM in PLC Channel

    OpenAIRE

    El ghzaoui Mohammed, Belkadid Jamal, Benbassou Ali

    2011-01-01

    One major drawback associated with an OFDM system is that the transmitter’soutput signal may have a high peak-to-average ratio (PAPR). High levels of PARmay be a limiting factor for power line communication (PLC) where regulatorybodies have fixed the maximum amount of transmit power. To overcome thisproblem, many approaches have been presented in the literature. One potentialsolution for reducing the peak-to-average power ratio (PAPR) in an OFDMsystem is to utilize a constant envelope OFDM (C...

  6. 75 FR 61363 - Airworthiness Directives; Rolls-Royce plc RB211-524 Series, -535 Series, RB211 Trent 700 Series...

    Science.gov (United States)

    2010-10-05

    ...-0993; Directorate Identifier 2010-NE-08-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc... Federal holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United... based on those comments. We will post all comments we receive, without change, to http://www.regulations...

  7. 76 FR 29814 - Statutory Debarment and Reinstatement of BAE Systems plc

    Science.gov (United States)

    2011-05-23

    ... Bureau of Political-Military Affairs; Statutory Debarment and Reinstatement of BAE Systems plc and Policy... of Defense Trade Controls Compliance, Bureau of Political-Military Affairs, Department of State (202... required. Statutory debarment is based solely upon conviction in a criminal proceeding, conducted by a...

  8. 78 FR 70489 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-11-26

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., and 560A2-61 turbofan engines. This AD requires replacement or repair of the low-pressure (LP...-61, 556B2-61, 560-61, and 560A2-61 turbofan engines. (d) Reason This AD was prompted by reports of...

  9. 77 FR 58762 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-09-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-Trent 892-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. That AD currently requires...-17, RB211-Trent 892B-17, and RB211-Trent 895-17 turbofan engines. (d) Unsafe Condition This AD was...

  10. 77 FR 37740 - Stagecoach Group plc and Coach USA, Inc., et al.-Acquisition of Control of Assets-American Coach...

    Science.gov (United States)

    2012-06-22

    ... Application. SUMMARY: On May 25, 2012, Stagecoach Group plc (Stagecoach), a noncarrier, and a number of its... Group plc and Coach USA, Inc., et al.--Acquisition of Control of Assets--American Coach Lines of Atlanta...) filed an application under 49 U.S.C. 14303 to acquire control of the assets of ten separate interstate...

  11. On an LAS-integrated soft PLC system based on WorldFIP fieldbus.

    Science.gov (United States)

    Liang, Geng; Li, Zhijun; Li, Wen; Bai, Yan

    2012-01-01

    Communication efficiency is lowered and real-time performance is not good enough in discrete control based on traditional WorldFIP field intelligent nodes in case that the scale of control in field is large. A soft PLC system based on WorldFIP fieldbus was designed and implemented. Link Activity Scheduler (LAS) was integrated into the system and field intelligent I/O modules acted as networked basic nodes. Discrete control logic was implemented with the LAS-integrated soft PLC system. The proposed system was composed of configuration and supervisory sub-systems and running sub-systems. The configuration and supervisory sub-system was implemented with a personal computer or an industrial personal computer; running subsystems were designed and implemented based on embedded hardware and software systems. Communication and schedule in the running subsystem was implemented with an embedded sub-module; discrete control and system self-diagnosis were implemented with another embedded sub-module. Structure of the proposed system was presented. Methodology for the design of the sub-systems was expounded. Experiments were carried out to evaluate the performance of the proposed system both in discrete and process control by investigating the effect of network data transmission delay induced by the soft PLC in WorldFIP network and CPU workload on resulting control performances. The experimental observations indicated that the proposed system is practically applicable. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  12. 78 FR 5 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-01-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-535E4-C-37 turbofan engines. This AD was prompted by an investigation by RR concluding that certain...- 535E4-B-37; RB211-535E4-B-75; and RB211-535E4-C-37 turbofan engines with intermediate-pressure (IP...

  13. 78 FR 37703 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-06-24

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) model RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines. This AD was prompted by low...) model RB211 Trent 768-60, 772-60, and 772B-60 turbofan engines. (d) Reason This AD was prompted by low...

  14. 78 FR 22180 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-04-15

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... 972B-84, RB211-Trent 977-84, RB211-Trent 977B-84, and RB211-Trent 980-84 turbofan engines. This AD... 977B-84, and RB211-Trent 980-84 turbofan engines that incorporate RR production Modification 72-G585 or...

  15. 77 FR 20508 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2012-04-05

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...-Trent 884B-17, RB211-Trent 892-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. That...-17, RB211- Trent 892B-17, and RB211-Trent 895-17 turbofan engines. On September 9, 2011, we also...

  16. Developing a PC-based expert system for fault analysis of reactor instruments

    International Nuclear Information System (INIS)

    Diwakar, M.P.; Rathod, N.C.; Bairi, B.R.; Darbhe, M.D.; Joglekar, S.S.

    1989-01-01

    This paper describes the development of an expert system for fault analysis of electronic instruments in the CIRUS nuclear reactor. The system was developed in Prolog on an IBM PC-XT compatible computer. A 'model-based' approach (Button et al, 1986) was adopted combining 'frames' and 'rules' to provide flexible control over the inferencing mechanisms. Frames represent the domain-objects as well as the inter-object relationships. They include 'demons' or 'active values' for triggering actions. Rules, along with frames, are used for fault analysis. The rules can be activated either in a data-driven or a goal-driven manner. The use of frames makes rule management easier. It is felt that developing in-house shell proved advantageous, compared to using commercially available shells. Choosing the model-based approach was efficient compared to a production system architecture. Therefore, the use of hybrid representations for diagnostic applications is advocated. Based on the experience, some general recommendations for developing such systems are presented. The expert system helps novice operators to understand the process of diagnosis and achieve a significant required level of competence. The system may not achieve the required level of proficiency by itself, but it can be used to train operators to become experts. (author). 12 refs

  17. What is the method in applying formal methods to PLC applications?

    NARCIS (Netherlands)

    Mader, Angelika H.; Engel, S.; Wupper, Hanno; Kowalewski, S.; Zaytoon, J.

    2000-01-01

    The question we investigate is how to obtain PLC applications with confidence in their proper functioning. Especially, we are interested in the contribution that formal methods can provide for their development. Our maxim is that the place of a particular formal method in the total picture of system

  18. Development of Remote Monitoring and a Control System Based on PLC and WebAccess for Learning Mechatronics

    OpenAIRE

    Wen-Jye Shyr; Te-Jen Su; Chia-Ming Lin

    2013-01-01

    This study develops a novel method for learning mechatronics using remote monitoring and control, based on a programmable logic controller (PLC) and WebAccess. A mechatronics module, a Web‐CAM and a PLC were integrated with WebAccess software to organize a remote laboratory. The proposed system enables users to access the Internet for remote monitoring and control of the mechatronics module via a web browser, thereby enhancing work flexibility by enabling personnel to control mechatronics equ...

  19. Comparative diagnostic efficacy of recombinant LLO and PI-PLC-based ELISAs for detection of listeriosis in animals.

    Science.gov (United States)

    Suryawanshi, Rahul D; Malik, Satya Veer Singh; Jayarao, Bhushan; Chaudhari, Sandeep P; Savage, Emily; Vergis, Jess; Kurkure, Nitin V; Barbuddhe, Sukhadeo B; Rawool, Deepak B

    2017-06-01

    The present study for the first time evaluates the serodiagnostic efficacy of two recombinant antigens namely, listeriolysin O (rLLO) and phosphatidyl-inositol phospholipase C (rPI-PLC). Indirect ELISA with the above recombinant antigens was used on samples collected from bovines (n=106), goats (n=138) and pigs (n=92) having either a history of abortion, emaciation and/or apparently healthy animals. Isolation of Listeria was attempted from the blood samples using USDA-FSIS method. On screening of test sera by rLLO-based ELISA, antibodies against anti-listeriolysin O (ALLO) were observed in goats (22.46%), bovines (15.10%) and pigs (16.31%). As advocated, after adsorption of positive serum samples with streptolysin O (SLO), the seropositivity for ALLO was marginally reduced (p>0.05) in goats (21.73%) and bovines (10.38%), whereas, in pigs the reduction (5.43%) was significant (pPLC-based ELISA revealed higher non-specific seropositivity for antilisterial antibodies in goats (45.65%), bovines (31.13%) and pigs (8.69%). Further, on comparing the seropositivity with isolation rate, of the 16 animals that were culturally-positive for L. monocytogenes, 15 showed ALLO positivity in unadsorbed as well as SLO-adsorbed sera by rLLO-based ELISA, however, rPI-PLC-based ELISA could detect seropositivity in only 5 animals. Moreover, rPI-PLC-based ELISA also showed seropositivity in those animals (7/30) that were culturally positive for other Listeria spp. In conclusion, rLLO can serve as a better antigen than rPI-PLC in ELISA for the serodiagnosis of listeriosis in animals; however, prior adsorption of test sera with SLO is required to avoid false positive results. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. The selective and inducible activation of endogenous PI 3-kinase in PC12 cells results in efficient NGF-mediated survival but defective neurite outgrowth.

    Science.gov (United States)

    Ashcroft, M; Stephens, R M; Hallberg, B; Downward, J; Kaplan, D R

    1999-08-12

    The Trk/Nerve Growth Factor receptor mediates the rapid activation of a number of intracellular signaling proteins, including phosphatidylinositol 3-kinase (PI 3-kinase). Here, we describe a novel, NGF-inducible system that we used to specifically address the signaling potential of endogenous PI 3-kinase in NGF-mediated neuronal survival and differentiation processes. This system utilizes a Trk receptor mutant (Trk(def)) lacking sequences Y490, Y785 and KFG important for the activation of the major Trk targets; SHC, PLC-gammal, Ras, PI 3-kinase and SNT. Trk(def) was kinase active but defective for NGF-induced responses when stably expressed in PC12nnr5 cells (which lack detectable levels of TrkA and are non-responsive to NGF). The PI 3-kinase consensus binding site, YxxM (YVPM), was introduced into the insert region within the kinase domain of Trk(def). NGF-stimulated tyrosine phosphorylation of the Trk(def)+PI 3-kinase addback receptor, resulted in the direct association and selective activation of PI 3-kinase in vitro and the production of PI(3,4)P2 and PI(3,4,5)P3 in vivo (comparable to wild-type). PC12nnr5 cells stably expressing Trk(def) + PI 3-kinase, initiated neurite outgrowth but failed to stably extend and maintain these neurites in response to NGF as compared to PC12 parental cells, or PC12nnr5 cells overexpressing wild-type Trk. However, Trk(def) + PI 3-kinase was fully competent in mediating NGF-induced survival processes. We propose that while endogenous PI 3-kinase can contribute in part to neurite initiation processes, its selective activation and subsequent signaling to downstream effectors such as Akt, functions mainly to promote cell survival in the PC12 system.

  1. 75 FR 27964 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-22B and RB211-524 Series Turbofan Engines

    Science.gov (United States)

    2010-05-19

    ...-1157; Directorate Identifier 2009-NE-26-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR... p.m., Monday through Friday, except Federal holidays. Fax: (202) 493-2251. Contact Rolls-Royce plc... received by the closing date and may amend this proposed AD based on those comments. We will post all...

  2. Performance Evaluation of CE-OFDM in PLC Channel

    OpenAIRE

    El Ghzaoui Mohammed; Belkadid Jamal; Benbassou Ali

    2011-01-01

    One major drawback associated with an OFDM system is that the transmitter’s output signal may have a high peak-to-average ratio (PAPR). High levels of PAR may be a limiting factor for power line communication (PLC) where regulatory bodies have fixed the maximum amount of transmit power. To overcome this problem, many approaches have been presented in the literature. One potential solution for reducing the peak-to-average power ratio (PAPR) in an OFDM system is to utilize a constant envelope O...

  3. Embedded PLC Webserver and Possibilities of its Utilization

    OpenAIRE

    Kopček Michal

    2016-01-01

    The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefo...

  4. 78 FR 60658 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-10-02

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT..., 892-17, 892B-17, and 895-17; and RB211-524G2-T-19, -524G3-T- 19, -524H-T-36, and -524H2-T-19 turbofan... (RR) model turbofan engines that have a high-pressure (HP) compressor stage 1 to 4 rotor disc...

  5. The application of PLC automatic control system for resin transfer in pulsed elution

    International Nuclear Information System (INIS)

    Long Maoxiong

    2001-01-01

    An application of Programmable Logic Controller (PLC) in automatic control system for resin transfer in pulsed elution column is described. The design principle as well as hardware and software are also described in detail

  6. Development of a PLC modem for data transmission over a PWM power supply

    Science.gov (United States)

    Batard, Christophe; Ginot, Nicolas; Mannah, Marc Anthony; Millet, Christophe; Poitiers, Frédéric

    2014-04-01

    In variable-speed electrical drive and online conditioning monitoring, a feedback loop is required in order to transmit the sensor information from the motor to the controller close to the inverter. Additional cabling is used for signalling. This extra cabling has a significant cost and data transmission may not be reliable. Thus, the use of power line communication (PLC) technology to transmit data in motor drive application is quite interesting. The use of a PLC modem dedicated to the home network in a three-phase inverter-fed motor power cable does not work. Therefore, specific coupling interfaces are developed to transmit data through a pulse-width modulated power supply. Laboratory tests have shown that the couplers are operating properly. They ensure reliable data transmission in a motor drive application.

  7. A Modification of Gamma Surveymeter Dosemeter 3007A for Monitoring Use Ethernet by PLC T100MD Series

    International Nuclear Information System (INIS)

    Ikhsan Shobari; Subchan, M.; Syahrudin Yusuf; Sutomo Budihardjo

    2010-01-01

    It has been modified a gamma surveymeter Dosemeter 3007A. The Surveymeter represents analogous surveymeter, so that an interface for data acquisition is required. Acquisition system from surveymeter is added to the voltage amplifier module from 0 - 200 mV to 0 - 5 V. This voltage value will represent of doses 0 - 5 mR/hour. Hereinafter the analogous signal 0 - 5 V as signal of input to peripheral of PLC T100MD series. Data in the form of processed analogous signal presented at local display of PLC. For long distance monitoring, data have been sent to a computer from PLC by ethernet. After this modification, the surveymeter can be used to monitor from long distance. By using Internet Service Provider, monitoring can be done at any time and any where as long as network internet is available. (author)

  8. The Cish SH2 domain is essential for PLC-γ1 regulation in TCR stimulated CD8+ T cells.

    Science.gov (United States)

    Guittard, Geoffrey; Dios-Esponera, Ana; Palmer, Douglas C; Akpan, Itoro; Barr, Valarie A; Manna, Asit; Restifo, Nicholas P; Samelson, Lawrence E

    2018-03-28

    Cish, participates within a multi-molecular E3 ubiquitin ligase complex, which ubiquitinates target proteins. It has an inhibitory effect on T cell activation mediated by PLC-γ1 regulation, and it functions as a potent checkpoint in CD8 + T cell tumor immunotherapy. To study the structural and functional relationships between Cish and PLC-γ1 during CD8 + T cell activation, we tested mutants of the Cish-SH2 (R107K) and D/BC (L222Q, C226Q) domains. We confirmed that Cish-SH2-specific binding was essential for PLC-γ1 ubiquitination and degradation. This domain was essential for the Cish-mediated inhibition of Ca 2+ release upon TCR stimulation. No effect on inhibition of cytokine release was observed with SH2 or D/BC mutants, although the absence of Cish led to an increased release of IFN-γ and TNF-α. Using imaging we showed that Cish was expressed mostly in the cytoplasm and we did not see any Cish clustering at the plasma membrane upon stimulation. We conclude that the Cish-SH2 domain is essential for PLC-γ1 regulation in TCR-stimulated CD8 + T cells.

  9. Methylmercury-induced toxicity is mediated by enhanced intracellular calcium through activation of phosphatidylcholine-specific phospholipase C

    International Nuclear Information System (INIS)

    Kang, Mi Sun; Jeong, Ju Yeon; Seo, Ji Heui; Jeon, Hyung Jun; Jung, Kwang Mook; Chin, Mi-Reyoung; Moon, Chang-Kiu; Bonventre, Joseph V.; Jung, Sung Yun; Kim, Dae Kyong

    2006-01-01

    Methylmercury (MeHg) is a ubiquitous environmental toxicant to which humans can be exposed by ingestion of contaminated food. MeHg has been suggested to exert its toxicity through its high reactivity to thiols, generation of arachidonic acid and reactive oxygen species (ROS), and elevation of free intracellular Ca 2+ levels ([Ca 2+ ] i ). However, the precise mechanism has not been fully defined. Here we show that phosphatidylcholine-specific phospholipase C (PC-PLC) is a critical pathway for MeHg-induced toxicity in MDCK cells. D609, an inhibitor of PC-PLC, significantly reversed the toxicity in a time- and dose-dependent manner with concomitant inhibition of the diacylglycerol (DAG) generation and the phosphatidylcholine (PC)-breakdown. MeHg activated the group IV cytosolic phospholipase A 2 (cPLA 2 ) and acidic form of sphingomyelinase (A-SMase) downstream of PC-PLC, but these enzymes as well as protein kinase C (PKC) were not linked to the toxicity by MeHg. Furthermore, MeHg produced ROS, which did not affect the toxicity. Addition of EGTA to culture media resulted in partial decrease of [Ca 2+ ] i and partially blocked the toxicity. In contrast, when the cells were treated with MeHg in the presence of Ca 2+ in the culture media, D609 completely prevented cell death with parallel decrease in [Ca 2+ ] i . Our results demonstrated that MeHg-induced toxicity was linked to elevation of [Ca 2+ ] i through activation of PC-PLC, but not attributable to the signaling pathways such as cPLA 2 , A-SMase, and PKC, or to the generation of ROS

  10. Development of Remote Monitoring and a Control System Based on PLC and WebAccess for Learning Mechatronics

    Directory of Open Access Journals (Sweden)

    Wen-Jye Shyr

    2013-02-01

    Full Text Available This study develops a novel method for learning mechatronics using remote monitoring and control, based on a programmable logic controller (PLC and WebAccess. A mechatronics module, a Web-CAM and a PLC were integrated with WebAccess software to organize a remote laboratory. The proposed system enables users to access the Internet for remote monitoring and control of the mechatronics module via a web browser, thereby enhancing work flexibility by enabling personnel to control mechatronics equipment from a remote location. Mechatronics control and long-distance monitoring were realized by establishing communication between the PLC and WebAccess. Analytical results indicate that the proposed system is feasible. The suitability of this system is demonstrated in the department of industrial education and technology at National Changhua University of Education, Taiwan. Preliminary evaluation of the system was encouraging and has shown that it has achieved success in helping students understand concepts and master remote monitoring and control techniques.

  11. Perancangan Prototype Early Warning System pada Kontrol On/Off Belt Conveyor Menggunakan PLC Siemens S7-300

    Directory of Open Access Journals (Sweden)

    Taufik Taufik

    2016-04-01

    Full Text Available Nowadays, automation system become an important aspect of the manufacturing process because could make integration manufacturing process on it more effective and more efficient. PLC or Programmable Logic Controller is one kind of automation system. Many industries use PLC as automation control device in the manufacturing process to control all kind of process. For example at transportation process of coals in generator industry. Coals could be burned because main elements of coals are carbon, hydrogen, and oxygen. Base on this prototype early warning system design, we get the result if sensor thermocouple detects temperature larger than setpoint temperature (it is 2000C, then PLC will give an order to shut down the output, that is a belt conveyor. The result of this prototype design could use at coals transportation as an early warning system. The design of prototype early warning system could detect and prevent fire because of the consequence of burned coals until spreading of fire could be avoided.

  12. One-way data transfer for PLC to VME status reporting at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Stein, S.J.

    1993-01-01

    The Personnel Safety System for the experimental beamlines at the Advanced Photon Source will use a large number of Allen Bradley Programmable Logic Controllers (PLC) to replace conventional relay logic. PLCs allow for the design of a very advanced safety system that can handle a large number of I/O points. Certain situations Require monitoring of the safety system from various locations around the storage ring via EPICS OPI (operator interface)consoles. This presentation covers the method of choice for transferring data from the Personnel Safety System into an EPICS database. Specifics on PLC ladder design, EPICS database design, and hardware selection are also discussed

  13. Embedded PLC Webserver and Possibilities of its Utilization

    Science.gov (United States)

    Kopček, Michal

    2016-12-01

    The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefore it was chosen as an example.

  14. Embedded PLC Webserver and Possibilities of its Utilization

    Directory of Open Access Journals (Sweden)

    Kopček Michal

    2016-12-01

    Full Text Available The concept Industry 4.0 is a top theme of recent times. Even if it represents the so-called 4th industrial revolution its main ideas could be used also to support the education of subjects from IT and automation. Furthermore, the basic IT and web technologies inherited by this concept are very well known to students. This paper introduces the embedded webserver of PLC and the options for its optimal utilization. The web server is essentially a simple and widely well-known technology, therefore it was chosen as an example.

  15. The natural sediment regime in rivers: broadening the foundation for ecosystem management

    Science.gov (United States)

    Wohl, Ellen E.; Bledsoe, Brian P.; Jacobson, Robert B.; Poff, N. LeRoy; Rathburn, Sara L.; Walters, David M.; Wilcox, Andrew C.

    2015-01-01

    Water and sediment inputs are fundamental drivers of river ecosystems, but river management tends to emphasize flow regime at the expense of sediment regime. In an effort to frame a more inclusive paradigm for river management, we discuss sediment inputs, transport, and storage within river systems; interactions among water, sediment, and valley context; and the need to broaden the natural flow regime concept. Explicitly incorporating sediment is challenging, because sediment is supplied, transported, and stored by nonlinear and episodic processes operating at different temporal and spatial scales than water and because sediment regimes have been highly altered by humans. Nevertheless, managing for a desired balance between sediment supply and transport capacity is not only tractable, given current geomorphic process knowledge, but also essential because of the importance of sediment regimes to aquatic and riparian ecosystems, the physical template of which depends on sediment-driven river structure and function.

  16. 78 FR 54152 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-09-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT...; -535C-37; -535E4-37; - 535E4-B-37, and -535E4-B-75 turbofan engines, and all RB211-524G2-19; - 524G3-19; -524H2-19; and -524H-36 turbofan engines. This AD requires a one-time inspection of the front combustion...

  17. PLC-based search and secure interlock system for the personnel safety in folded tandem ion accelerator

    International Nuclear Information System (INIS)

    Padmakumar, Sapna; Subramanyum, N.B.V.; Bhatt, Jignesh P.; Ware, Shailaja V.; Kansara, M.J.; Gupta, S.K.; Singh, P.

    2006-01-01

    Safety of the personnel is one of the key issues addressed in any accelerator project. The FOTIA facility at BARC is capable of operating under standard operation conditions without any radiation hazard. Even then for a safe and reliable operation of FOTIA a PLC (Programmable logic controller) based interlock system has been implemented. This interlocking system is compact, modular, flexible, robust and easy for troubleshooting. These advantages led to the popularity of PLC rather than using a relay-based system. This paper highlights the salient features of the search and secure interlock for the personal safety of FOTIA. (author)

  18. Process control through the incorporation of PLC networks in service radiation facilities

    International Nuclear Information System (INIS)

    Moehlmann, J.H.F.

    1990-01-01

    In order to ensure the smooth and safe running and operation of an irradiation facility, several regulations must be complied with, most of which are prescribed by the authorities. However, internal working regulations, based on years of practical experience, are of equal importance. The application of computers, micro-processors and PLCs, in combination with semi-conductor electronics, has improved process control considerably. Not only can every step in the process and even each detailed function be controlled, but also the combination of the different functions. By using PLC-systems in combination with computers, important data can be stored, recorded and presented in such a way that the technical staff can be warned in advance of breakdowns or undesirable deviations in the process parameters. Keeping a log of these data will help guarantee the correct functioning of the irradiation facility. It is even possible with these modern PLC techniques to monitor the control-console, so that each operation is recorded and accessible. (author)

  19. Commercial information system of Slovak Electricity Transmission System, Plc

    International Nuclear Information System (INIS)

    Laznicka, L.

    2004-01-01

    Commercial Information System (CIS), which main role of is to support the commercial activities of the company, is built up by business department of SEPS, Plc in close co-operation with the supplier company Sfera, Plc. The system entries are data from electricity meters obtained by automatized data acquisition and from bugging sheets, contractual hour diagrams, parameters of transmission system like measuring schemes and formulas for calculation of demand and supply, contractual data resulting from agreements, business conditions, URSO decisions and valid legislative. A part of the system is also support of process of data evaluation like calculation of transmitted energy quantity, calculation of actual output diagrams, comparison of actual and contractual diagrams, calculation of system divergence, calculation of demand divergence, etc. The final price for the drawings of services, which are joined with transmission of the electric power will be determined by the accounting process. In this causality there are automatically made out invoices for access, losses, system charges, system services, short-term and long-term transits, divergences and for cross-border transmission auctions. System also generates various specialized synopses and statistics for the evaluation requirements of important aspects and for parameter observations. Successive liberalisation of the electricity power market, changes in legislative and URSO decisions require CIS to be sufficiently configurable and to adapt flexible on the alternating environs. (author)

  20. Linking sediment-charcoal records and ecological modeling to understand causes of fire-regime change in boreal forests

    Science.gov (United States)

    Linda B. Brubaker; Philip E. Higuera; T. Scott Rupp; Mark A. Olson; Patricia M. Anderson; Feng Sheng. Hu

    2009-01-01

    Interactions between vegetation and fire have the potential to overshadow direct effects of climate change on fire regimes in boreal forests of North America. We develop methods to compare sediment-charcoal records with fire regimes simulated by an ecological model, ALFRESCO (Alaskan Frame-based Ecosystem Code) and apply these methods to evaluate potential causes of a...

  1. ELIPGRID-PC: Upgraded version

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1995-12-01

    Evaluating the need for and the effectiveness of remedial cleanup at waste sites often includes finding average contaminant concentrations and identifying pockets of contamination called hot spots. The standard tool for calculating the probability of detecting pockets of contamination called hot spots has been the ELIPGRID code of singer and Wickman. The ELIPGRID-PC program has recently made this algorithm available for an IBM reg-sign personal computer (PC) or compatible. A new version of ELIPGRID-PC, incorporating Monte Carlo test results and simple graphics, is herein described. Various examples of how to use the program for both single and multiple hot spot cases are given. The code for an American National Standards Institute C version of the ELIPGRID algorithm is provided, and limitations and further work are noted. This version of ELIPGRID-PC reliably meets the goal of moving Singer's ELIPGRID algorithm to the PC

  2. On Verification of PLC-Programs Written in the LD-Language

    Directory of Open Access Journals (Sweden)

    E. V. Kuzmin

    2012-01-01

    Full Text Available We discuss some questions connected with the construction of a technology of analysing correctness of Programmable Logic Controller programs. We consider an example of modeling and automated verification of PLC-programs written in the Ladder Diagram language (including timed function blocks of the IEC 61131-3 standard. We use the Cadence SMV for symbolic model checking. Program properties are written in the linear-time temporal logic LTL.

  3. 75 FR 33738 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-524 Series and RB211 Trent 500, 700, and 800...

    Science.gov (United States)

    2010-06-15

    ...-0562; Directorate Identifier 2009-NE-29-AD] RIN 2120-AA64 Airworthiness Directives; Rolls-Royce plc (RR...-2251. Contact Rolls-Royce plc, P.O. Box 31, Derby, DE24 8BJ, United Kingdom; phone: 011 44 1332 242424... amend this proposed AD based on those comments. We will post all comments we receive, without change, to...

  4. On the spacecraft attitude stabilization in the orbital frame

    Directory of Open Access Journals (Sweden)

    Antipov Kirill A.

    2012-01-01

    Full Text Available The paper deals with spacecraft in the circular near-Earth orbit. The spacecraft interacts with geomagnetic field by the moments of Lorentz and magnetic forces. The octupole approximation of the Earth’s magnetic field is accepted. The spacecraft electromagnetic parameters, namely the electrostatic charge moment of the first order and the eigen magnetic moment are the controlled quasiperiodic functions. The control algorithms for the spacecraft electromagnetic parameters, which allows to stabilize the spacecraft attitude position in the orbital frame are obtained. The stability of the spacecraft stabilized orientation is proved both analytically and by PC computations.

  5. Framing the frame

    Directory of Open Access Journals (Sweden)

    Todd McElroy

    2007-08-01

    Full Text Available We examined how the goal of a decision task influences the perceived positive, negative valence of the alternatives and thereby the likelihood and direction of framing effects. In Study 1 we manipulated the goal to increase, decrease or maintain the commodity in question and found that when the goal of the task was to increase the commodity, a framing effect consistent with those typically observed in the literature was found. When the goal was to decrease, a framing effect opposite to the typical findings was observed whereas when the goal was to maintain, no framing effect was found. When we examined the decisions of the entire population, we did not observe a framing effect. In Study 2, we provided participants with a similar decision task except in this situation the goal was ambiguous, allowing us to observe participants' self-imposed goals and how they influenced choice preferences. The findings from Study 2 demonstrated individual variability in imposed goal and provided a conceptual replication of Study 1. %need keywords

  6. Characterisation of the flow regimes of arbitrary manoeuvre in absolute and relative frames

    CSIR Research Space (South Africa)

    Gledhill, Irvy MA

    2011-09-01

    Full Text Available ?ping, Link?ping, Sweden ? CSIR 2009 www.csir.co.za Outline Warning: this is a theory paper ? Context ? Background ? Some of the CFD background ? Computational background ? Theoretical background ? In the relative frame... ? CSIR 2011 www.csir.co.za Context ? Engineering tools useless without? ? Engineering judgment which is based on? ? Understanding ? CSIR 2009 www.csir.co.za Objectives: overall ? A formal framework...

  7. Analysis of interleukin (IL)-1 beta and transforming growth factor (TGF)-beta-induced signal transduction pathways in IL-2 and TGF-beta secretion and proliferation in the thymoma cell line EL4.NOB-1.

    Science.gov (United States)

    Siese, A; Jaros, P P; Willig, A

    1999-02-01

    In the present study we investigated the interleukin (IL)-1beta and transforming growth factor-beta1 (TGF-beta1)-mediated proliferation, and production of IL-2 and TGF-beta, in the murine T-cell line, EL4.NOB-1. This cell line is resistant to TGF-beta concerning growth arrest but not autoinduction or suppression of IL-1-induced IL-2 production. When cocultured with IL-1beta, TGF-beta showed growth-promoting activity that could be antagonized by adding the phosphatidyl choline-dependent phospholipase C (PC-PLC) inhibitor, D609. Using specific enzyme inhibitors of protein kinases (PK) C and A, mitogen-activated protein kinase (MAPK), phospholipase A2 (PLA2), phosphatidylinositol-dependent (PI)-PLC and PC-PLC, we showed that IL-1beta-induced IL-2 synthesis was dependent on all investigated kinases and phospholipases, except PC-PLC. TGF-beta1 was able to inhibit IL-2 synthesis by the activation of PKA and MAPK. The same kinases are involved in TGF-beta autoinduction that is accompanied by a secretion of the active but not the latent growth factor and is antagonized by IL-1beta. Addition of the PI-PLC inhibitor, ET 18OCH3, or the PLA2 inhibitor (quinacrine) alone, resulted in secretion of latent TGF-beta and, in the case of ET 18OCH3, active TGF-beta. These data implicate a role for PI-PLC and PLA2 in the control of latency and secretion. Analysis of specific tyrosine activity and c-Fos expression showed synergistic but no antagonistic effects. These events are therefore not involved in IL- and TGF-beta-regulated IL-2 and TGF-beta production, but might participate in IL-1/TGF-beta-induced growth promotion.

  8. Framing the frame

    OpenAIRE

    Todd McElroy; John J. Seta

    2007-01-01

    We examined how the goal of a decision task influences the perceived positive, negative valence of the alternatives and thereby the likelihood and direction of framing effects. In Study 1 we manipulated the goal to increase, decrease or maintain the commodity in question and found that when the goal of the task was to increase the commodity, a framing effect consistent with those typically observed in the literature was found. When the goal was to decrease, a framing effect opposite to the ty...

  9. Cybersecurity Vulnerability Analysis of the PLC PRIME Standard

    Directory of Open Access Journals (Sweden)

    Miguel Seijo Simó

    2017-01-01

    Full Text Available Security in critical infrastructures such as the power grid is of vital importance. The Smart Grid puts power grid classical security approach on the ropes, since it introduces cyberphysical systems where devices, communications, and information systems must be protected. PoweRline Intelligent Metering Evolution (PRIME is a Narrowband Power-Line Communications (NB-PLC protocol widely used in the last mile of Advanced Metering Infrastructure (AMI deployments, playing a key role in the Smart Grid. Therefore, this work aims to unveil the cybersecurity vulnerabilities present in PRIME standard, proposing solutions and validating and discussing the results obtained.

  10. AUTOMATION OF GLASS TEMPERING FURNACE BY USING PLC

    Directory of Open Access Journals (Sweden)

    Abdullah BÜYÜKYILDIZ

    2007-02-01

    Full Text Available In this study, a furnace which is used for observation of environments under high temperature, and also used for manufacturing of glasses which are resisted to high temperature has been designed and implemented. Automation of this system has been done by using PLC. Operating parameters of furnace such as materials entering, the furnace, the local temperature control of furnace, cooling control and materials outing have been sensed with Hall Effect Sensor. Furthermore, the observation of parameters of furnace on screen has been provided with SCADA software. Obtained products have been shown the system works successfully.

  11. Integrated software environment dedicated for implementation of control systems based on PLC controllers

    Directory of Open Access Journals (Sweden)

    Szymon SURMA

    2007-01-01

    Full Text Available Industrial processes’ control systems based on PLC controllers play today a very important role in all fields of transport, including also sea transport. Construction of control systems is the field of engineering, which has been continuously evolving towards maximum simplification of system design path. Up to now the time needed forthe system construction from the design to commissioning had to be divided into a few stages. A mistake made in an earlier stage caused that in most cases the next stages had to be restarted. Available debugging systems allows defect detection at an early stage of theproject implementation. The paper presents general characteristic of integrated software for implementation of complex control systems. The issues related to the software use for programming of the visualisation environment, control computer, selection oftransmission medium and transmission protocol as well as PLC controllers’ configuration, software and control have been analysed.

  12. Design and control of multifunctional sorting and training platform based on PLC control

    Science.gov (United States)

    Wan, Hongqiang; Ge, Shuai; Han, Peiying; Li, Fancong; Zhang, Simiao

    2018-05-01

    Electromechanical integration, as a multi-disciplinary subject, has been paid much attention by universities and is widely used in the automation production of enterprises. Aiming at the problem of the lack of control among enterprises and the lack of training among colleges and universities, this paper presents a design of multifunctional sorting training platform based on PLC control. Firstly, the structure of the platform is determined and three-dimensional modeling is done. Then design the platform's aerodynamic control and electrical control. Finally, realize the platform sorting function through PLC programming and configuration software development. The training platform can be used to design the practical training experiment, which has a strong advance and pertinence in the electromechanical integration teaching. At the same time, the platform makes full use of modular thinking to make the sorting modules more flexible. Compared with the traditional training platform, its teaching effect is more significant.

  13. Automation of Underground Cable Laying Equipment Using PLC and Hmi

    Science.gov (United States)

    Mal Kothari, Kesar; Samba, Vishweshwar; Tania, Kinza; Udayakumar, R., Dr; Karthikeyan, Ram, Dr

    2018-04-01

    Underground cable laying is an alternative for overhead cable laying of telecommunication and power transmission lines. It is becoming very popular in recent times because of some of its advantages over overhead cable laying. This type of cable laying is mostly practiced in developed countries because it is more expensive than overhead cable laying. Underground cable laying is more suitable when land is not available, and it also increases the aesthetics. This paper implements the automation on a manually operated cable pulling winch machine using programmable logic controller (PLC). Winch machines are useful in underground cable laying. The main aim of the project is to replace all the mechanical functions with electrical controls which are operated through a touch screen (HMI). The idea is that the machine should shift between parallel and series circuit automatically based on the pressure sensed instead of manually operating the solenoid valve. Traditional means of throttling the engine using lever and wire is replaced with a linear actuator. Sensors such as proximity, pressure and load sensor are used to provide the input to the system. The HMI used will display the speed, length and tension of the rope being winded. Ladder logic is used to program the PLC.

  14. PC-BLAS, PC Linear Algebra Subroutines

    International Nuclear Information System (INIS)

    Hanson, R.J.

    1989-01-01

    1 - Description of program or function: PC-BLAS is a highly optimized version of the Basic Linear Algebra Subprograms (BLAS), a standardized set of 38 routines that perform low-level operations on vectors of numbers in single- and double-precision real and complex arithmetic. Routines are included to find the index of the largest component of a vector, apply a Givens or modified Givens rotation, multiply a vector by a constant, determine the Euclidean length, perform a dot product, swap and copy vectors, and find the norm of a vector. 2 - Restrictions on the complexity of the problem: The number of components in any vector and the spacing or stride between their entries must not exceed 32,767 (2 15 -1). PC-BLAS will not work with an 80286 CPU operating in 'protected' mode

  15. An automatic energy-saving and thermal monitoring/controlling system for a pond

    Directory of Open Access Journals (Sweden)

    Cheng Ching-Chien

    2017-01-01

    Full Text Available Because of low temperatures and oxygen in cold water, fish will die when cold currents arrive. This will cause tremendous loss of money. In order reduce the cooling of the pond, an automatic thermal detecting and cold-roofing system using a wind-proofing device, heaters, and thermal detectors is proposed. To reduce heat loss due to thermal convection above the pond surface, a motor-driven wind-proofing device automatically controlled by a PLC controller is adopted. Here, the wind-proofing device, thermal detectors, and heating system are connected to the PLC controller. The PLC will also be connected to the PC interface. The temperature thresholds used to trigger the heater and the wind proofing device can be set at the PC interface. Two options for manipulating the heating and the automatic heating can be selected. The related wind-proofing area and the number of heaters will be determined according to the current temperature. Moreover, the PLC can be wirelessly connected to the server PC in the control room. The pond keeper can monitor everything online and control the pond water's temperature. With this, the problem of fish dying in a cold wave can be solved. Consequently, to reduce the electrical exhaust when heating up the pond water, green energy, solar energy and wind energy, is used.

  16. Generic requirements specification for qualifying a commercially available PLC for safety-related applications in nuclear power plants. Final report

    International Nuclear Information System (INIS)

    Ostenso, A.; May, R.

    1996-12-01

    This is a specification for qualifying a commercially available PLC for application to safety systems in nuclear power plants. The specifications are suitable for evaluating a particular PLC product line as a platform for safety-related applications, establishing a suitable qualification test program, and confirming that the manufacturer has a quality assurance program that is adequate for safety-related applications or is sufficiently complete that, with a reasonable set of compensatory actions, it can be brought into conformance. The specification includes requirements for: (1) quality assurance measures applied to the qualification activities, (2) documentation to support the qualification, and (3) documentation to provide the information needed for applying the qualified PLC platform to a specific application. The specifications are designed to encompass a broad range of safety applications; however, qualifying a particular platform for a different range of applications can be accomplished by appropriate adjustments to the requirements

  17. Fuel cycle and waste management: A perspective from British nuclear fuels plc

    International Nuclear Information System (INIS)

    Holmes, R.G.G.; Fairhall, G.A.; Robbins, R.A.

    1996-01-01

    The phrase fuel cycle and waste management implies two separate and distinct activities. British Nuclear Fuels plc (BNFL) has adopted a holistic approach to the fuel cycle that integrates the traditional fuel cycle activities of conversion to uranium hexafluoride, fuel fabrication, power generation, and reprocessing with waste arisings, its subsequent treatment, and disposal

  18. 78 FR 61168 - Airworthiness Directives; Rolls-Royce plc Turbofan Engines

    Science.gov (United States)

    2013-10-03

    ... Airworthiness Directives; Rolls-Royce plc Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT... (RR) RB211-535E4-37, RB211-535E4-B-37, RB211-535E4-C- 37, and RB211-535E4-B-75 turbofan engines. This...-37, RB211-535E4-B-37, RB211-535E4-C-37, and RB211-535E4-B-75 turbofan engines. (d) Unsafe Condition...

  19. Peak Pc Prediction in Conjunction Analysis: Conjunction Assessment Risk Analysis. Pc Behavior Prediction Models

    Science.gov (United States)

    Vallejo, J.J.; Hejduk, M.D.; Stamey, J. D.

    2015-01-01

    Satellite conjunction risk typically evaluated through the probability of collision (Pc). Considers both conjunction geometry and uncertainties in both state estimates. Conjunction events initially discovered through Joint Space Operations Center (JSpOC) screenings, usually seven days before Time of Closest Approach (TCA). However, JSpOC continues to track objects and issue conjunction updates. Changes in state estimate and reduced propagation time cause Pc to change as event develops. These changes a combination of potentially predictable development and unpredictable changes in state estimate covariance. Operationally useful datum: the peak Pc. If it can reasonably be inferred that the peak Pc value has passed, then risk assessment can be conducted against this peak value. If this value is below remediation level, then event intensity can be relaxed. Can the peak Pc location be reasonably predicted?

  20. Dealing with Phrase Level Co-Articulation (PLC) in speech recognition: a first approach

    NARCIS (Netherlands)

    Ordelman, Roeland J.F.; van Hessen, Adrianus J.; van Leeuwen, David A.; Robinson, Tony; Renals, Steve

    1999-01-01

    Whereas nowadays within-word co-articulation effects are usually sufficiently dealt with in automatic speech recognition, this is not always the case with phrase level co-articulation effects (PLC). This paper describes a first approach in dealing with phrase level co-articulation by applying these

  1. Generating Safety-Critical PLC Code From a High-Level Application Software Specification

    Science.gov (United States)

    2008-01-01

    The benefits of automatic-application code generation are widely accepted within the software engineering community. These benefits include raised abstraction level of application programming, shorter product development time, lower maintenance costs, and increased code quality and consistency. Surprisingly, code generation concepts have not yet found wide acceptance and use in the field of programmable logic controller (PLC) software development. Software engineers at Kennedy Space Center recognized the need for PLC code generation while developing the new ground checkout and launch processing system, called the Launch Control System (LCS). Engineers developed a process and a prototype software tool that automatically translates a high-level representation or specification of application software into ladder logic that executes on a PLC. All the computer hardware in the LCS is planned to be commercial off the shelf (COTS), including industrial controllers or PLCs that are connected to the sensors and end items out in the field. Most of the software in LCS is also planned to be COTS, with only small adapter software modules that must be developed in order to interface between the various COTS software products. A domain-specific language (DSL) is a programming language designed to perform tasks and to solve problems in a particular domain, such as ground processing of launch vehicles. The LCS engineers created a DSL for developing test sequences of ground checkout and launch operations of future launch vehicle and spacecraft elements, and they are developing a tabular specification format that uses the DSL keywords and functions familiar to the ground and flight system users. The tabular specification format, or tabular spec, allows most ground and flight system users to document how the application software is intended to function and requires little or no software programming knowledge or experience. A small sample from a prototype tabular spec application is

  2. 76 FR 1985 - Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes

    Science.gov (United States)

    2011-01-12

    ... Airworthiness Directives; Short Brothers PLC Model SD3 Airplanes AGENCY: Federal Aviation Administration (FAA..., at an average labor rate of $85 per work hour. Required parts cost about $10 per product. Based on.... The average labor rate is $85 per work-hour. Based on these figures, we estimate the cost of the AD on...

  3. Model to Counter the Threats in the Data Transmission System PLC-based Technology with the Use of Petri Nets

    Directory of Open Access Journals (Sweden)

    A. A. Balaev

    2010-06-01

    Full Text Available In the article the most important aspects of information security technology Power Line Communica tions, namely the provision of conditions accessibility and integrity, are considered. It is shown that these aspects of the PLC-Technology has some internal “potential” counter, at least, such a widespread threat to both natural disturbances and/or artificial origin. The possibility of such an implementation using the simplified mathematical model of the PLC-based technologies of the theory of Petri nets is presented.

  4. Repairing and Upgrading Your PC

    CERN Document Server

    Thompson, Robert

    2009-01-01

    Repairing and Upgrading Your PC delivers start-to-finish instructions, simple enough for even the most inexperienced PC owner, for troubleshooting, repairing, and upgrading your computer. Written by hardware experts Robert Bruce Thompson and Barbara Fritchman Thompson, this book covers it all: how to troubleshoot a troublesome PC, how to identify which components make sense for an upgrade, and how to tear it all down and put it back together. This book shows how to repair and upgrade all of your PC's essential components.

  5. ANALYSING PERFORMANCE ASSESSMENT IN PUBLIC SERVICES: HOW USEFUL IS THE CONCEPT OF A PERFORMANCE REGIME?

    Science.gov (United States)

    Martin, Steve; Nutley, Sandra; Downe, James; Grace, Clive

    2016-03-01

    Approaches to performance assessment have been described as 'performance regimes', but there has been little analysis of what is meant by this concept and whether it has any real value. We draw on four perspectives on regimes - 'institutions and instruments', 'risk regulation regimes', 'internal logics and effects' and 'analytics of government' - to explore how the concept of a multi-dimensional regime can be applied to performance assessment in public services. We conclude that the concept is valuable. It helps to frame comparative and longitudinal analyses of approaches to performance assessment and draws attention to the ways in which public service performance regimes operate at different levels, how they change over time and what drives their development. Areas for future research include analysis of the impacts of performance regimes and interactions between their visible features (such as inspections, performance indicators and star ratings) and the veiled rationalities which underpin them.

  6. Development of the radiation control system for personal permission, status and record

    International Nuclear Information System (INIS)

    Miyamoto, A.; Yamazaki, H.; Yuki, H.; Nanao, M.; Sugawara, Y.; Ohtsuki, T.

    2003-01-01

    The radiation control system for automated locks, personal status, and recordings in the database was developed at Laboratory of Nuclear Science (LNS), Tohoku University. It consists of the Programmable Logic Controllers (PLC) for the entrance system and Windows PC. The PLC is controlled with Fins Gateway and Compolet on the Windows PC through an ethernet. The SQL Server 2000 was also installed on the Windows PC for database management. In the system, personal data such as destination, purpose, working hours and radiation dose are stored in the database. Furthermore, monthly report of personal data can easily be printed out by using the system. Personal status can be checked by a status monitor of the accelerator in the operation room and the entrance of the radiation controlled area, etc. (author)

  7. The PC graphics handbook

    CERN Document Server

    Sanchez, Julio

    2003-01-01

    Part I - Graphics Fundamentals PC GRAPHICS OVERVIEW History and Evolution Short History of PC Video PS/2 Video Systems SuperVGA Graphics Coprocessors and Accelerators Graphics Applications State-of-the-Art in PC Graphics 3D Application Programming Interfaces POLYGONAL MODELING Vector and Raster Data Coordinate Systems Modeling with Polygons IMAGE TRANSFORMATIONS Matrix-based Representations Matrix Arithmetic 3D Transformations PROGRAMMING MATRIX TRANSFORMATIONS Numeric Data in Matrix Form Array Processing PROJECTIONS AND RENDERING Perspective The Rendering Pipeline LIGHTING AND SHADING Lightin

  8. Homeplug AV and IEEE 1901 a handbook for PLC designers and users

    CERN Document Server

    Latchman, Haniph A; Yonge, Larry; Gavette, Sherman

    2013-01-01

      The only authorized book explaining the HomePlug networking standards HomePlug is a growing technology for creating high-speed Power Line Communication (PLC) networks by transmitting data over in-home or in-office power lines. Users only need to plug adapters into wall outlets to create an instant network of computers, printers, routers, home entertainment

  9. Histamine acting on H1 receptor promotes inhibition of proliferation via PLC, RAC, and JNK-dependent pathways

    International Nuclear Information System (INIS)

    Notcovich, Cintia; Diez, Federico; Tubio, Maria Rosario; Baldi, Alberto; Kazanietz, Marcelo G.; Davio, Carlos; Shayo, Carina

    2010-01-01

    It is well established that histamine modulates cell proliferation through the activation of the histamine H1 receptor (H1R), a G protein-coupled receptor (GPCR) that is known to couple to phospholipase C (PLC) activation via Gq. In the present study, we aimed to determine whether H1R activation modulates Rho GTPases, well-known effectors of Gq/G 11 -coupled receptors, and whether such modulation influences cell proliferation. Experiments were carried out in CHO cells stably expressing H1R (CHO-H1R). By using pull-down assays, we found that both histamine and a selective H1R agonist activated Rac and RhoA in a time- and dose-dependent manner without significant changes in the activation of Cdc42. Histamine response was abolished by the H1R antagonist mepyramine, RGS2 and the PLC inhibitor U73122, suggesting that Rac and RhoA activation is mediated by H1R via Gq coupling to PLC stimulation. Histamine caused a marked activation of serum response factor activity via the H1R, as determined with a serum-responsive element (SRE) luciferase reporter, and this response was inhibited by RhoA inactivation with C3 toxin. Histamine also caused a significant activation of JNK which was inhibited by expression of the Rac-GAP β2-chimaerin. On the other hand, H1R-induced ERK1/2 activation was inhibited by U73122 but not affected by C3 or β2-chimaerin, suggesting that ERK1/2 activation was dependent on PLC and independent of RhoA or Rac. [ 3 H]-Thymidine incorporation assays showed that both histamine and the H1R agonist inhibited cell proliferation in a dose-dependent manner and that the effect was independent of RhoA but partially dependent on JNK and Rac. Our results reveal that functional coupling of the H1R to Gq-PLC leads to the activation of RhoA and Rac small GTPases and suggest distinct roles for Rho GTPases in the control of cell proliferation by histamine.

  10. Metodología para la implementación de controlador difuso tipo Takagi-Sugeno en PLC s7-300

    Directory of Open Access Journals (Sweden)

    Cristian Guarnizo Lemus

    2011-12-01

    Full Text Available This paper presents a methodology for implementing fuzzy logic controllers based on a S7-300 PLC using the programming language SCL(Structured Control Language in STEP 7. We present the design of the fuzzy function, variable declarations, and the evaluation design of membership functions and rules of the fuzzy system. Since this scheme can be implemented more complex fuzzy models, such as adaptive or Autotuner. We present an application example for a discrete time simulated in the PLC using a PI fuzzy controller.

  11. Interlock System for the COMPASS Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Hron, M.; Adamek, J.; Pisacka, J.; Panek, R. [Institute of Plasma Physics AS CR, Association EURATOM/IPP.CR, Prague (Czech Republic); Sova, J.; Siba, J.; Kovarj, J. [Department of Control Engineering, Faculty of Electrical Engineering, Prague (Czech Republic)

    2009-07-01

    Full text of publication follows: The COMPASS tokamak (R=0.56 m, a=0.18 - 0.23 m) is starting operation presently at Institute of Plasma Physics AS CR in Prague. An important issue of the operation is the safety of the personnel and machine protection against faults, presented in this contribution. The personnel protection is based on a restricted access into the experimental hall during the operation of potentially dangerous systems. A tokamak hall access system, based on Honeywell WIN-PAK (tm) 2005, allows to set the status of the experimental area (open/closed) and to control the in and out movement of persons using access cards. On top of this, a check of the whole experimental area by the operator is enforced before the hall enclosure. A hardware interlock then interprets the experimental hall status and controls the operation of key systems accordingly. The permit for operation is granted and the real status of the systems is reported by hard wired potential less contacts. The control procedure is based on a PLC MicroPEL M66. This PLC provides HW interface between Actuators (Relays and switches) and it is connected on PESNET bus. Its programming is done using language Simple v.2 in Winstudio IDE. Second site of personnel protection system is created on PC where runs a .NET application on MSWindows XP or 2000. This PC is connected with PLC via PESNET bus (on RS485 layer) and it generates all control signals to PLC from the operator. Simultaneously, the PC receives all warning and alarm signals from the PLC. This signals are displayed on a screen of the PC in real-time, this way the GUI provides visualization of the controlled process. Except for this fact the operator is informed about the status of the system and individual subsystems on a PC via an operator's panel. Further we will describe the machine protection which uses similar system for checking conditions for the start of a shot. Fast key processes which have to be checked during the shot are

  12. Design of monitoring system for mail-sorting based on the Profibus S7 series PLC

    Science.gov (United States)

    Zhang, W.; Jia, S. H.; Wang, Y. H.; Liu, H.; Tang, G. C.

    2017-01-01

    With the rapid development of the postal express, the workload of mail sorting is increasing, but the automatic technology of mail sorting is not mature enough. In view of this, the system uses Siemens S7-300 PLC as the main station controller, PLC of Siemens S7-200/400 is from the station controller, through the man-machine interface configuration software MCGS, PROFIBUS-DP communication, RFID technology and mechanical sorting hand achieve mail classification sorting monitoring. Among them, distinguish mail-sorting by scanning RFID posted in the mail electronic bar code (fixed code), the system uses the corresponding controller on the acquisition of information processing, the processed information transmit to the sorting manipulator by PROFIBUS-DP. The system can realize accurate and efficient mail sorting, which will promote the development of mail sorting technology.

  13. Comparative analysis of different configurations of PLC-based safety systems from reliability point of view

    Science.gov (United States)

    Tapia, Moiez A.

    1993-01-01

    The study of a comparative analysis of distinct multiplex and fault-tolerant configurations for a PLC-based safety system from a reliability point of view is presented. It considers simplex, duplex and fault-tolerant triple redundancy configurations. The standby unit in case of a duplex configuration has a failure rate which is k times the failure rate of the standby unit, the value of k varying from 0 to 1. For distinct values of MTTR and MTTF of the main unit, MTBF and availability for these configurations are calculated. The effect of duplexing only the PLC module or only the sensors and the actuators module, on the MTBF of the configuration, is also presented. The results are summarized and merits and demerits of various configurations under distinct environments are discussed.

  14. The alcator C-MOD control system

    International Nuclear Information System (INIS)

    Bosco, J.; Fairfax, S.

    1992-01-01

    The Alcator C-MOD experiment includes over 30 engineering and diagnostic subsystems. The control system hardware and software is a mixture of custom and commercial products which includes sensors, signal conditioners, hard-wired controls, programmable logic controllers, displays, a hybrid analog/digital computer, networked personal computers, and networked VAX workstations. This paper describes the computer-based portions of the control system. The control system coordinates all C-MOD systems including power, vacuum, heating and cooling, access control, plasma shape and position control, and diagnostics. Programmable logic controllers (PLC's) are located near each subsystem. The control room is isolated by fiber optics. Functions that are essential to personnel or equipment safety (e.g. access control) are implemented in hardwired logic and monitored but not controlled by the PLC's. The initial configuration will include over 25 Allen-Bradley PLC-5 units. The PLCs in each subsystem are connected to personal computers (PC's) in the control room. The PC's provide graphical displays and operator interface. The Pc's are networked and share process data with each other and with a master control console and a large mimic panel

  15. Inhibitory Effect of Chinese Propolis on Phosphatidylcholine-Specific Phospholipase C Activity in Vascular Endothelial Cells

    Directory of Open Access Journals (Sweden)

    Hongzhuan Xuan

    2011-01-01

    Full Text Available To understand the mechanisms underlying the anti-inflammatory action of Chinese propolis, we investigated its effect on the activity of phosphatidylcholine-specific phospholipase C (PC-PLC that plays critical roles in control of vascular endothelial cell (VEC function and inflammatory responses. Furthermore, p53 and reactive oxygen species (ROS levels and mitochondrial membrane potential (Δψm were investigated. Our data indicated that treatment of Chinese propolis 6.25 and 12.5 μg/ml for 12 hours increased VEC viability obviously. Exposure to Chinese propolis 6.25, 12.5, and 25 μg/ml for 6 and 12 hours significantly decreased PC-PLC activity and p53 level, and ROS levels were depressed by Chinese propolis 12.5 μg/ml and 25 μg/ml dramatically. The Δψm of VECs was not affected by Chinese propolis at low concentration but disrupted by the propolis at 25 μg/ml significantly, which indicated that Chinese propolis depressed PC-PLC activity and the levels of p53 and ROS in VECs but disrupted Δψm at a high concentration.

  16. Compulsory licensing in Canada and Thailand: comparing regimes to ensure legitimate use of the WTO rules.

    Science.gov (United States)

    Lybecker, Kristina M; Fowler, Elisabeth

    2009-01-01

    This paper examines two recent examples of compulsory licensing legislation: one globally embraced regime and one internationally controversial regime operating under the same WTO rules. In particular, we consider Canadian legislation and the use of compulsory licensing for HIV/AIDS drugs destined for a developing country. This is then contrasted with the conditions under which Thai authorities are pursuing compulsory licenses, the outcomes of their compulsory licenses, as well as the likely impact of the Thai policy. Finally, we construct a rubric to evaluate characteristics of a successful regime. This is used to analyze the Canadian and Thai regimes and frame the expected implications of each national policy. It is hoped that the assessment will guide changes to compulsory licensing design to ensure that legitimate regimes are embraced while illegitimate ones are disallowed.

  17. Trust and Collaboration in PLC Teams: Teacher Relationships, Principal Support, and Collaborative Benefits

    Science.gov (United States)

    Hallam, Pamela R.; Smith, Henry R.; Hite, Julie M.; Hite, Steven J.; Wilcox, Bradley R.

    2015-01-01

    Professional learning communities (PLCs) are being recognized as effective in improving teacher collaboration and student achievement. Trust is critical in effectively implementing the PLC model, and the school principal is best positioned to influence school trust levels. Using five facets of trust, this research sought to clarify the impact of…

  18. CoPc and CoPcF16 on gold: Site-specific charge-transfer processes

    Directory of Open Access Journals (Sweden)

    Fotini Petraki

    2014-04-01

    Full Text Available Interface properties of cobalt(II phthalocyanine (CoPc and cobalt(II hexadecafluoro-phthalocyanine (CoPcF16 to gold are investigated by photo-excited electron spectroscopies (X-ray photoemission spectroscopy (XPS, ultraviolet photoemission spectroscopy (UPS and X-ray excited Auger electron spectroscopy (XAES. It is shown that a bidirectional charge transfer determines the interface energetics for CoPc and CoPcF16 on Au. Combined XPS and XAES measurements allow for the separation of chemical shifts based on different local charges at the considered atom caused by polarization effects. This facilitates a detailed discussion of energetic shifts of core level spectra. The data allow the discussion of site-specific charge-transfer processes.

  19. Some relationship between G-frames and frames

    Directory of Open Access Journals (Sweden)

    Mehdi Rashidi-Kouchi

    2015-06-01

    Full Text Available In this paper we proved that every g-Riesz basis for Hilbert space $H$ with respect to $K$ by adding a condition is a Riesz basis for Hilbert $B(K$-module $B(H,K$. This is an extension of [A. Askarizadeh,M. A. Dehghan, {em G-frames as special frames}, Turk. J. Math., 35, (2011 1-11]. Also, we derived similar results for g-orthonormal and orthogonal bases. Some relationships between dual frame, dual g-frame and exact frame and exact g-frame are presented too.

  20. Sequence variation in the alpha-toxin encoding plc gene of Clostridium perfringens strains isolated from diseased and healthy chickens

    DEFF Research Database (Denmark)

    Abildgaard, L; Engberg, RM; Pedersen, Karl

    2009-01-01

    The aim of the present study was to analyse the genetic diversity of the alpha-toxin encoding plc gene and the variation in a-toxin production of Clostridium perfringens type A strains isolated from presumably healthy chickens and chickens suffering from either necrotic enteritis (NE) or cholangio......-hepatitis. The a-toxin encoding plc genes from 60 different pulsed-field gel electrophoresis (PFGE) types (strains) of C perfringens were sequenced and translated in silico to amino acid sequences and the a-toxin production was investigated in batch cultures of 45 of the strains using an enzyme...

  1. Enhanced Operation of Electricity Distribution Grids Through Smart Metering PLC Network Monitoring, Analysis and Grid Conditioning

    Directory of Open Access Journals (Sweden)

    Iker Urrutia

    2013-01-01

    Full Text Available Low Voltage (LV electricity distribution grid operations can be improved through a combination of new smart metering systems’ capabilities based on real time Power Line Communications (PLC and LV grid topology mapping. This paper presents two novel contributions. The first one is a new methodology developed for smart metering PLC network monitoring and analysis. It can be used to obtain relevant information from the grid, thus adding value to existing smart metering deployments and facilitating utility operational activities. A second contribution describes grid conditioning used to obtain LV feeder and phase identification of all connected smart electric meters. Real time availability of such information may help utilities with grid planning, fault location and a more accurate point of supply management.

  2. Study on the Development of Builtin PLC%内嵌式PLC的设计与实现

    Institute of Scientific and Technical Information of China (English)

    刘家亮; 熊晓红; 黄树槐

    2001-01-01

    介绍了PLC编程语言——语句表的结构和特点,讨论了语句表解释程序的词法分析和语法分析技术,以及运用面向对象的编程思想、构造语句表解释程序,实现内嵌式PLC等问题。%In this thesis, the architecture and character of the PLC languageSTL are introduced. And then, the structure of STL interpreting program and the technique of lexical analysis and syntax analysis are discussed. Develop the STL interpreting program with the idea of OOP(objectoriented programming), realized the builtin PLC are also attempted.

  3. Power supply system on HT-7 tokamak for diagnostic neutral beam based on PLC

    International Nuclear Information System (INIS)

    Zhang Jian; Liu Baohua; Ding Tonghai; Du Shaowu

    2006-01-01

    A power supply system for diagnostic neutral beam on the HT-7 Tokamak was developed. Its logic control system based on S7-300 PLC was described. The experimental results show that the system is easy to operate and its performance is reliable. (authors)

  4. Chameleonic dilaton, nonequivalent frames, and the cosmological constant problem in quantum string theory

    International Nuclear Information System (INIS)

    Zanzi, Andrea

    2010-01-01

    The chameleonic behavior of the string theory dilaton is suggested. Some of the possible consequences of the chameleonic string dilaton are analyzed in detail. In particular, (1) we suggest a new stringy solution to the cosmological constant problem and (2) we point out the nonequivalence of different conformal frames at the quantum level. In order to obtain these results, we start taking into account the (strong coupling) string loop expansion in the string frame (S-frame), therefore the so-called form factors are present in the effective action. The correct dark energy scale is recovered in the Einstein frame (E-frame) without unnatural fine-tunings and this result is robust against all quantum corrections, granted that we assume a proper structure of the S-frame form factors in the strong coupling regime. At this stage, the possibility still exists that a certain amount of fine-tuning may be required to satisfy some phenomenological constraints. Moreover in the E-frame, in our proposal, all the interactions are switched off on cosmological length scales (i.e., the theory is IR-free), while higher derivative gravitational terms might be present locally (on short distances) and it remains to be seen whether these facts clash with phenomenology. A detailed phenomenological analysis is definitely necessary to clarify these points.

  5. Design of Usui bridge (PC cable stayed bridge). Usuihashi (PC shachokyo) no sekkei ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Kido, M.; Iizuka, Y. (Japan Highway Public Corp., Tokyo (Japan)); Tanaka, S.; Otsuka, K. (P.S. Concrete Co. Ltd. Kajima Corp. Joint Venture, Tokyo (Japan)); Kitakuni, S. (Kajima Corp., Tokyo (Japan))

    1991-11-30

    Structure and design of single suspension PC cable bridge, which is first kind of high way bridge in Japan and aiming to start for general use by March, 1993, are reported. As a construction outline, main construction quantity and general layout of the whole bridge together with the selective detail and characteristics of the diagonal member, tower, main girder and tower support member, are cited. Design conditions( load, materials, allowable stress and others ), basic plan of the design, and structure analysis( surface stress framed structure analysis, stereoscopic framework analysis and FEM analysis of local stress ) are explained. Design of structure member like main girder is based on diagonal member tension, wave shearing force, level of diagonal strain stress, bending stress when diagonal member anchors the deformed main tower caused by living load during earth quake, principal stress of main tower junction and local stress etc. Main tower support member design is based on the results of corbel shearing force at varied cross section and main stress, and diagonal member design is decided by allowable stress. Diagonal member anchorage traverse beam design depends on bending moment of traverse beam and shearing force. 3 refs., 15 figs., 1 tab.

  6. PC/104 Embedded IOCs at Jefferson Lab

    International Nuclear Information System (INIS)

    Yan, Jianxun; Allison, Trent; Witherspoon, Sue; Cuffe, Anthony

    2009-01-01

    Jefferson Lab has developed embedded IOCs based on PC/104 single board computers (SBC) for low level control systems. The PC/104 IOCs run EPICS on top of the RTEMS operating system. Two types of control system configurations are used in different applications, PC/104 SBC with commercial PC/104 I/O cards and PC/104 SBC with custom designed FPGA-based boards. RTEMS was built with CEXP shell to run on the PC/104 SBC. CEXP shell provides the function of dynamic object loading, which is similar to the widely used VxWorks operating system. Standard software configurations were setup for PC/104 IOC application development to provide a familiar format for new projects as well as ease the conversion of applications from VME based IOCs to PC/104 IOCs. Many new projects at Jefferson Lab are going to employ PC/104 SBCs as IOCs and some applications have already been running them for accelerator operations. The PC/104 - RTEMS IOC provides a free open source Real-Time Operating System (RTOS), low cost/maintenance, easily installed/ configured, flexible, and reliable solution for accelerator control and 12GeV Upgrade projects.

  7. Functional Analysis of Mouse G6pc1 Mutations Using a Novel In Situ Assay for Glucose-6-Phosphatase Activity and the Effect of Mutations in Conserved Human G6PC1/G6PC2 Amino Acids on G6PC2 Protein Expression.

    Directory of Open Access Journals (Sweden)

    Kayla A Boortz

    Full Text Available Elevated fasting blood glucose (FBG has been associated with increased risk for development of type 2 diabetes. Single nucleotide polymorphisms (SNPs in G6PC2 are the most important common determinants of variations in FBG in humans. Studies using G6pc2 knockout mice suggest that G6pc2 regulates the glucose sensitivity of insulin secretion. G6PC2 and the related G6PC1 and G6PC3 genes encode glucose-6-phosphatase catalytic subunits. This study describes a functional analysis of 22 non-synonymous G6PC2 SNPs, that alter amino acids that are conserved in human G6PC1, mouse G6pc1 and mouse G6pc2, with the goal of identifying variants that potentially affect G6PC2 activity/expression. Published data suggest strong conservation of catalytically important amino acids between all four proteins and the related G6PC3 isoform. Because human G6PC2 has very low glucose-6-phosphatase activity we used an indirect approach, examining the effect of these SNPs on mouse G6pc1 activity. Using a novel in situ functional assay for glucose-6-phosphatase activity we demonstrate that the amino acid changes associated with the human G6PC2 rs144254880 (Arg79Gln, rs149663725 (Gly114Arg and rs2232326 (Ser324Pro SNPs reduce mouse G6pc1 enzyme activity without affecting protein expression. The Arg79Gln variant alters an amino acid mutation of which, in G6PC1, has previously been shown to cause glycogen storage disease type 1a. We also demonstrate that the rs368382511 (Gly8Glu, rs138726309 (His177Tyr, rs2232323 (Tyr207Ser rs374055555 (Arg293Trp, rs2232326 (Ser324Pro, rs137857125 (Pro313Leu and rs2232327 (Pro340Leu SNPs confer decreased G6PC2 protein expression. In summary, these studies identify multiple G6PC2 variants that have the potential to be associated with altered FBG in humans.

  8. Protease-activated receptor-2 stimulates intestinal epithelial chloride transport through activation of PLC and selective PKC isoforms.

    Science.gov (United States)

    van der Merwe, Jacques Q; Moreau, France; MacNaughton, Wallace K

    2009-06-01

    Serine proteases play important physiological roles through their activity at G protein-coupled protease-activated receptors (PARs). We examined the roles that specific phospholipase (PL) C and protein kinase (PK) C (PKC) isoforms play in the regulation of PAR(2)-stimulated chloride secretion in intestinal epithelial cells. Confluent SCBN epithelial monolayers were grown on Snapwell supports and mounted in modified Ussing chambers. Short-circuit current (I(sc)) responses to basolateral application of the selective PAR(2) activating peptide, SLIGRL-NH(2), were monitored as a measure of net electrogenic ion transport caused by PAR(2) activation. SLIGRL-NH(2) induced a transient I(sc) response that was significantly reduced by inhibitors of PLC (U73122), phosphoinositol-PLC (ET-18), phosphatidylcholine-PLC (D609), and phosphatidylinositol 3-kinase (PI3K; LY294002). Immunoblot analysis revealed the phosphorylation of both PLCbeta and PLCgamma following PAR(2) activation. Pretreatment of the cells with inhibitors of PKC (GF 109203X), PKCalpha/betaI (Gö6976), and PKCdelta (rottlerin), but not PKCzeta (selective pseudosubstrate inhibitor), also attenuated this response. Cellular fractionation and immunoblot analysis, as well as confocal immunocytochemistry, revealed increases of PKCbetaI, PKCdelta, and PKCepsilon, but not PKCalpha or PKCzeta, in membrane fractions following PAR(2) activation. Pretreatment of the cells with U73122, ET-18, or D609 inhibited PKC activation. Inhibition of PI3K activity only prevented PKCdelta translocation. Immunoblots revealed that PAR(2) activation induced phosphorylation of both cRaf and ERK1/2 via PKCdelta. Inhibition of PKCbetaI and PI3K had only a partial effect on this response. We conclude that basolateral PAR(2)-induced chloride secretion involves activation of PKCbetaI and PKCdelta via a PLC-dependent mechanism resulting in the stimulation of cRaf and ERK1/2 signaling.

  9. The electromagnetic compatibility of the PLC technology; La compatibilite electromagnetique de la technologie CPL. Des donnees sur les lignes electriques

    Energy Technology Data Exchange (ETDEWEB)

    Bermudez, J.-L.; Marthe, E.; Rachidi, F.; Rubinstein, M.; Vukicevic, A.

    2006-07-01

    PLC (Power Line Communications) in Europe or BPL (Broadband over Power Lines) in the US are techniques that allows the utilization of low and middle voltage power lines for the transmission of high frequencies by coupling electrical signals to them. In this way, unshielded power lines may be used for the transmission of numerical information similar to the well known xDSL-techniques using telephone lines. Typically, the frequency range used by PLC is between 9 kHz and 30 MHz. The authors describe the general principles and investigate possible electromagnetic interference with existing radio frequency equipment like xDSL, CATV (Cable Television) and Wireless (GSM, Bluetooth, WiFi). Finally, they present theoretical and experimental results of techniques allowing the reduction of such interference by reducing the emission of electromagnetic signals from PLC systems. The preferred method is based on an active control by injecting an auxiliary signal into the third conductor (ground)

  10. Turnaround and Sustainability in Economic Crisis: The Case of NEXT PLC

    OpenAIRE

    Zhang, Biyan

    2013-01-01

    Purpose- against a background of continued weak economic conditions and with many firms experiencing declining financial performance, this paper presents a synthesis of the business turnaround literature and combines with analysis case –NEXT plc. It purposes to discus the turnaround strategies can keep the declining firm sustainability recovery, during the economic cycle. \\ud \\ud Design/methodology/approach- the turnaround strategy for sustainability recovery are examined by a case study of N...

  11. Formal verification of complex properties on PLC programs

    CERN Document Server

    Darvas, D; Voros, A; Bartha, T; Blanco Vinuela, E; Gonzalez Suarez, V M

    2014-01-01

    Formal verification has become a recommended practice in the safety-critical application areas. However, due to the complexity of practical control and safety systems, the state space explosion often prevents the use of formal analysis. In this paper we extend our former verification methodology with effective property preserving reduction techniques. For this purpose we developed general rule-based reductions and a customized version of the Cone of Influence (COI) reduction. Using these methods, the verification of complex requirements formalised with temporal logics (e.g. CTL, LTL) can be orders of magnitude faster. We use the NuSMV model checker on a real-life PLC program from CERN to demonstrate the performance of our reduction techniques.

  12. PC'eren på arbejde. 3. udgave

    DEFF Research Database (Denmark)

    Andersen, Povl Erik Rostgård

    En generel og ikke-programspecifik introduktion til edb-området med speciel fokus på pc'er og pc-programmel.......En generel og ikke-programspecifik introduktion til edb-området med speciel fokus på pc'er og pc-programmel....

  13. Design and construction the identification of nitriding plasma process parameters using personal computer based on serial communication

    International Nuclear Information System (INIS)

    Frida Iswinning Diah; Slamet Santosa

    2012-01-01

    Design and construction the identification of process parameters using personal computer based on serial communication PLC M-series has been done. The function of this device is to identify the process parameters of a system (plan), to which then be analyzed and conducted a follow-up given to the plan by the user. The main component of this device is the M-Series T100MD1616 PLC and personal computer (PC). In this device the data plan parameters obtained from the corresponding sensor outputs in the form of voltage or current. While the analog parameter data is adjusted to the ADC analog input of the PLC using a signal conditioning system. Then, as the parameter is processed by the PLC then sent to a PC via RS232 to be displayed in the form of graphs or tables and stored in the database. Software to program the database is created using Visual Basic Programming V-6. The device operation test is performed for the measurement of temperature parameter and vacuum level on the plasma nitriding machine. The results indicate that the device has functioning as an identification device parameters process of plasma nitriding machine. (author)

  14. On transforms between Gabor frames and wavelet frames

    DEFF Research Database (Denmark)

    Christensen, Ole; Goh, Say Song

    2013-01-01

    We describe a procedure that enables us to construct dual pairs of wavelet frames from certain dual pairs of Gabor frames. Applying the construction to Gabor frames generated by appropriate exponential Bsplines gives wavelet frames generated by functions whose Fourier transforms are compactly...... supported splines with geometrically distributed knot sequences. There is also a reverse transform, which yields pairs of dual Gabor frames when applied to certain wavelet frames....

  15. Evaluation of a fast PLC module in prospect of the LHC beam interlock system

    CERN Document Server

    Zaera-Sanz, Manuel

    2005-01-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of mseconds. Siemens has introduced a “so called” fast module (FM352-5 Boolean Processor) that provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This note publishes the results of this study. As well, this note could be useful for other applications requiring fast processing using a PLC.

  16. Design and application of the high-voltage DC power-supply control system based on PLC

    International Nuclear Information System (INIS)

    Huang Yiyun; Zheng Guanghua; Wu Junshuan; Yang Chunsheng; Hu Huaichuan

    2002-03-01

    The design and application of A kind of high-voltage DC power-supply control system based on PLC is referred, in addition, KingView is used to monitor the system in real time and manage the man-machine conversation ideally

  17. IBM PC/IX operating system evaluation plan

    Science.gov (United States)

    Dominick, Wayne D. (Editor); Granier, Martin; Hall, Philip P.; Triantafyllopoulos, Spiros

    1984-01-01

    An evaluation plan for the IBM PC/IX Operating System designed for IBM PC/XT computers is discussed. The evaluation plan covers the areas of performance measurement and evaluation, software facilities available, man-machine interface considerations, networking, and the suitability of PC/IX as a development environment within the University of Southwestern Louisiana NASA PC Research and Development project. In order to compare and evaluate the PC/IX system, comparisons with other available UNIX-based systems are also included.

  18. Dynamic regime of coherent population trapping and optimization of frequency modulation parameters in atomic clocks.

    Science.gov (United States)

    Yudin, V I; Taichenachev, A V; Basalaev, M Yu; Kovalenko, D V

    2017-02-06

    We theoretically investigate the dynamic regime of coherent population trapping (CPT) in the presence of frequency modulation (FM). We have formulated the criteria for quasi-stationary (adiabatic) and dynamic (non-adiabatic) responses of atomic system driven by this FM. Using the density matrix formalism for Λ system, the error signal is exactly calculated and optimized. It is shown that the optimal FM parameters correspond to the dynamic regime of atomic-field interaction, which significantly differs from conventional description of CPT resonances in the frame of quasi-stationary approach (under small modulation frequency). Obtained theoretical results are in good qualitative agreement with different experiments. Also we have found CPT-analogue of Pound-Driver-Hall regime of frequency stabilization.

  19. WORKBENCH FOR CONTROL SYSTEMS TRIALS BASED ON VIPA 300 CONTROLLER AND ADVANTECH INPUT/OUTPUT CARD

    Directory of Open Access Journals (Sweden)

    M. V. Levinskyi

    2015-01-01

    Full Text Available The topic is about workbench creation for control systems trials based on VIPA 300 industrial PLC and model of control object which is implemented in MatLab Simulink program on PC. Connection between controller and the PC is provided by the Advantech PCI-1711 input/output card of discrete and analog signals. Object identification,control system synthesis, creation of control device structure and its parametrical identification, as a rule, is done on a PC in a modelling environment, e.g. in MatLab. But often, using this PC modelling, the hardware and software features of algorithms which were obtained during system synthesis are not considered in a specific industrial PLC.It is considered a good idea to use a composite version where obtained algorithms are tested in a real industrial PLC and control object is substituted by a model which is working on a PC in real time scale. In this case software realization of algorithms in a specific PLC are fully taken into account and substitution of real control object by itsmodel considerably reduces the costs for carrying out experiments and allows to study the system behavior when control object parameters and modes of operation vary greatly. The creation of workbench stipulates several stages: configuration and programming of industrial PLC VIPA 313 SC, installation and configuration of Advantech PCI- 1711 input/output card, tuning of Simulink modelling environment for working in real time scale using Real-Time Windows Target Library, testing of workbench by using constant and harmonic signals of different frequencies. Work results of virtual stabilization system are compared with combined version. In virtual stabilization system PID governor and control object are implemented in Simulink. In combined version control object is still implemented in Simulink and PID governor - in VIPA 313 SC controller (using functional block FB58 from Step7 standard library.

  20. Junior PC-Kørekort

    DEFF Research Database (Denmark)

    Hansbøl, Mikala; Mathiasen, Helle

    udviklingsprojekt med forsøg med DANSK IT's Junior PC-kørekort® som metode og redskab til at evaluere og dokumentere elevernes IT-kompetencer. Projektet blev gennemført i perioden fra 2002-2003 og afsluttet i foråret 2003. Rapporten er baseret på kvalitative case studier af elever og læreres arbejde med Junior PC......-kørekort® prøverne. DANSK IT's Junior PC-kørekort® kan betragtes som et forsøg på at etablere en bestemt fælleskulturel tilgang til elevernes IT-kompetencer i folkeskolen. Ud fra et situeret læringsperspektiv problematiserer rapporten anvendelsen af de standardiserede prøver som metode til at dokumentere og evaluere...... elevernes IT-kompetencer. Rapporten (2MB) fylder 80 sider ekskl. bilag. Bemærk, at forskningsrapporten handler om Dansk IT's Junior PC-kørekort - ikke at forveksle med det IT-bevis for folkeskolens elever, som Undevisningsministeriet har udviklet. Dette IT-bevis koncept skiftede navn i januar 2004, hvor...

  1. Měření výpočetního výkonu PLC PFC200

    OpenAIRE

    Majchrák, František

    2017-01-01

    V práci sa analyzujú možnosti merania výpočetného výkonu PLC PFC200 od firmy WAGO. Prvú časť práce venujem priblíženiu funkčnosti automatu, jeho využitiu, jednotlivým možnostiam programovania, zoznamujem sa s implementáciou vlastných programových blokov v prostredí embedded Linux a zisťujem jeho prepojenie s PLC prostredím. V druhej časti práce sa sústredím na meranie výkonu, jeho typy, popis certifikovaných meraní a jeho celkové zhodnotenie. V poslednej časti je vysvetlená aplikácia, ktorá z...

  2. Phosphatidylcholine (PC) biosynthesis in pancreatic islets of Langerhans

    International Nuclear Information System (INIS)

    Hoffman, J.M.; Laychock, S.G.

    1986-01-01

    Islets of Langerhans isolated from rat pancreata were incubated with [ 14 C]choline to determine the biosynthesis of PC by the CDP choline to determine the biosynthesis of PC by the CDPcholine pathway. Recovery of [ 14 C]PC in islet membranes was time-related, and stimulated by glucose (17mM) during 60 min. The rate of PC synthesis was constant during 60 min with glucose stimulation. In contrast, the sulfonylurea tolbutamide (2 mM) reduced the recovery of [ 14 C]choline in PC, and 8-bromo-cyclic AMP (5 mM) did not significantly affect [ 14 C]PC recovery. Incubation of islets in Ca 2+ -free medium enhanced glucose-stimulated recovery of [ 14 C]choline-labeled PC due to the inhibition of phospholipase and phospholipid hydrolysis. Inhibition of CTP:phosphocholine cytidylyltransferase with 5-deoxy-5'-isobutylthioadenosine (SIBA) reduced [ 14 C]PC levels and insulin release in a concentration dependent manner. Treatment with SIBA also reduced Mg 2+ -dependent Ca 2+ -ATPase activity in islet microsomes. Quantitation of membrane PC showed that glucose stimulation did not alter islet P levels. Thus, islet PC biosynthesis is linked to glucose stimulation and contributes to the maintenance of PC levels in membranes undergoing exocytosis and phospholipid hydrolysis. Adequate PC levels support Ca 2+ pump activity and secretory mechanisms

  3. Azimuthal propagation and frequency characteristic of compressional Pc 5 waves observed at geostationary orbit

    International Nuclear Information System (INIS)

    Takahashi, K.; Higbie, P.R.; Baker, D.N.

    1985-01-01

    Energetic particle data from the 1977-007 and 1979-053 satellites and magnetic field data from the GOES 2 and 3 satellites have been used to study eight compressional Pc 5 wave events observed at geostationary orbit during 1979. All the events occurred on the dayside, and most of them were observed during the recovery phase of a geomagnetic storm. By using the data from two of the satellites which were close to each other, we measured the azimuthal phase velocity V/sub phi/ and azimuthal wave number m for selected intervals. For all these intervals the waves propagated westward in the spacecraft frame, and we obtained Vertical Bar V/sub phi/ Vertical Bar = 4--14 km/s and Vertical Bar m Vertical Bar = 40--120. In addition, harmonics of a local standing Alfven wave were often present simultaneously with a compressional Pc 5 wave. The frequency of the compressional wave was typically 25% of that of the second harmonic of the Alfven wave. These observed features are discussed in the light of existing theories of instabilities in the ring current plasma

  4. Attribute Framing and Goal Framing Effects in Health Decisions.

    Science.gov (United States)

    Krishnamurthy, Parthasarathy; Carter, Patrick; Blair, Edward

    2001-07-01

    Levin, Schneider, and Gaeth (LSG, 1998) have distinguished among three types of framing-risky choice, attribute, and goal framing-to reconcile conflicting findings in the literature. In the research reported here, we focus on attribute and goal framing. LSG propose that positive frames should be more effective than negative frames in the context of attribute framing, and negative frames should be more effective than positive frames in the context of goal framing. We test this framework by manipulating frame valence (positive vs negative) and frame type (attribute vs goal) in a unified context with common procedures. We also argue that the nature of effects in a goal-framing context may depend on the extent to which the research topic has "intrinsic self-relevance" to the population. In the context of medical decision making, we operationalize low intrinsic self-relevance by using student subjects and high intrinsic self-relevance by using patients. As expected, we find complete support for the LSG framework under low intrinsic self-relevance and modified support for the LSG framework under high intrinsic self-relevance. Overall, our research appears to confirm and extend the LSG framework. Copyright 2001 Academic Press.

  5. Design of a PLC control program for a batch plant : VHS case study 1

    NARCIS (Netherlands)

    Mader, A.H.; Brinksma, E.; Wupper, H.; Bauer, N.

    2001-01-01

    This article reports on the systematic design and validation of a PLC control program for the batch plant that has been selected as a case study for the EC project on Verification of Hybrid Systems (VHS). We show how a correct design of the control program can be obtained in an incremental manner

  6. Design of a PLC Control Program for a Batch Plant - VHS Case Study 1

    NARCIS (Netherlands)

    Mader, Angelika H.; Brinksma, Hendrik; Wupper, H.; Bauer, N.

    2001-01-01

    This article reports on the systematic design and validation of a PLC control program for the batch plant that has been selected as a case study for the EC project on Verification of Hybrid Systems (VHS). We show how a correct design of the control program can be obtained in an incremental manner

  7. Solid-state framing camera with multiple time frames

    Energy Technology Data Exchange (ETDEWEB)

    Baker, K. L.; Stewart, R. E.; Steele, P. T.; Vernon, S. P.; Hsing, W. W.; Remington, B. A. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States)

    2013-10-07

    A high speed solid-state framing camera has been developed which can operate over a wide range of photon energies. This camera measures the two-dimensional spatial profile of the flux incident on a cadmium selenide semiconductor at multiple times. This multi-frame camera has been tested at 3.1 eV and 4.5 keV. The framing camera currently records two frames with a temporal separation between the frames of 5 ps but this separation can be varied between hundreds of femtoseconds up to nanoseconds and the number of frames can be increased by angularly multiplexing the probe beam onto the cadmium selenide semiconductor.

  8. Quality assessment of platelet concentrates prepared by platelet rich plasma-platelet concentrate, buffy coat poor-platelet concentrate (BC-PC and apheresis-PC methods

    Directory of Open Access Journals (Sweden)

    Singh Ravindra

    2009-01-01

    Full Text Available Background: Platelet rich plasma-platelet concentrate (PRP-PC, buffy coat poor-platelet concentrate (BC-PC, and apheresis-PC were prepared and their quality parameters were assessed. Study Design: In this study, the following platelet products were prepared: from random donor platelets (i platelet rich plasma - platelet concentrate (PRP-PC, and (ii buffy coat poor- platelet concentrate (BC-PC and (iii single donor platelets (apheresis-PC by different methods. Their quality was assessed using the following parameters: swirling, volume of the platelet concentrate, platelet count, WBC count and pH. Results: A total of 146 platelet concentrates (64 of PRP-PC, 62 of BC-PC and 20 of apheresis-PC were enrolled in this study. The mean volume of PRP-PC, BC-PC and apheresis-PC was 62.30±22.68 ml, 68.81±22.95 ml and 214.05±9.91 ml and ranged from 22-135 ml, 32-133 ml and 200-251 ml respectively. The mean platelet count of PRP-PC, BC-PC and apheresis-PC was 7.6±2.97 x 1010/unit, 7.3±2.98 x 1010/unit and 4.13±1.32 x 1011/unit and ranged from 3.2-16.2 x 1010/unit, 0.6-16.4 x 1010/unit and 1.22-8.9 x 1011/unit respectively. The mean WBC count in PRP-PC (n = 10, BC-PC (n = 10 and apheresis-PC (n = 6 units was 4.05±0.48 x 107/unit, 2.08±0.39 x 107/unit and 4.8±0.8 x 106/unit and ranged from 3.4 -4.77 x 107/unit, 1.6-2.7 x 107/unit and 3.2 - 5.2 x 106/unit respectively. A total of 26 units were analyzed for pH changes. Out of these units, 10 each were PRP-PC and BC-PC and 6 units were apheresis-PC. Their mean pH was 6.7±0.26 (mean±SD and ranged from 6.5 - 7.0 and no difference was observed among all three types of platelet concentrate. Conclusion: PRP-PC and BC-PC units were comparable in terms of swirling, platelet count per unit and pH. As expected, we found WBC contamination to be less in BC-PC than PRP-PC units. Variation in volume was more in BC-PC than PRP-PC units and this suggests that further standardization is required for preparation of BC-PC

  9. Enhanced expression of Gqα and PLC-β1 proteins contributes to vascular smooth muscle cell hypertrophy in SHR: role of endogenous angiotensin II and endothelin-1.

    Science.gov (United States)

    Atef, Mohammed Emehdi; Anand-Srivastava, Madhu B

    2014-07-01

    Vascular Gqα signaling has been shown to contribute to cardiac hypertrophy. In addition, angiotensin II (ANG II) was shown to induce vascular smooth muscle cell (VSMC) hypertrophy through Gqα signaling; however, the studies on the role of Gqα and PLC-β1 proteins in VSMC hypertrophy in animal model are lacking. The present study was therefore undertaken to examine the role of Gqα/PLC-β1 proteins and the signaling pathways in VSMC hypertrophy using spontaneously hypertensive rats (SHR). VSMC from 16-wk-old SHR and not from 12-wk-old SHR exhibited enhanced levels of Gqα/PLC-β1 proteins compared with age-matched Wistar-Kyoto (WKY) rats as determined by Western blotting. However, protein synthesis as determined by [(3)H]leucine incorporation was significantly enhanced in VSMC from both 12- and 16-wk-old SHR compared with VSMC from age-matched WKY rats. Furthermore, the knockdown of Gqα/PLC-β1 in VSMC from 16-wk-old SHR by antisense and small interfering RNA resulted in attenuation of protein synthesis. In addition, the enhanced expression of Gqα/PLC-β1 proteins, enhanced phosphorylation of ERK1/2, and enhanced protein synthesis in VSMC from SHR were attenuated by the ANG II AT1 and endothelin-1 (ET-1) ETA receptor antagonists losartan and BQ123, respectively, but not by the ETB receptor antagonist BQ788. In addition, PD98059 decreased the enhanced expression of Gqα/PLC-β1 and protein synthesis in VSMC from SHR. These results suggest that the enhanced levels of endogenous ANG II and ET-1 through the activation of AT1 and ETA receptors, respectively, and MAP kinase signaling, enhanced the expression of Gqα/PLC-β1 proteins in VSMC from 16-wk-old SHR and result in VSMC hypertrophy. Copyright © 2014 the American Physiological Society.

  10. Amarogentin, a secoiridoid glycoside, abrogates platelet activation through PLC γ 2-PKC and MAPK pathways.

    Science.gov (United States)

    Yen, Ting-Lin; Lu, Wan-Jung; Lien, Li-Ming; Thomas, Philip Aloysius; Lee, Tzu-Yin; Chiu, Hou-Chang; Sheu, Joen-Rong; Lin, Kuan-Hung

    2014-01-01

    Amarogentin, an active principle of Gentiana lutea, possess antitumorigenic, antidiabetic, and antioxidative properties. Activation of platelets is associated with intravascular thrombosis and cardiovascular diseases. The present study examined the effects of amarogentin on platelet activation. Amarogentin treatment (15~60  μM) inhibited platelet aggregation induced by collagen, but not thrombin, arachidonic acid, and U46619. Amarogentin inhibited collagen-induced phosphorylation of phospholipase C (PLC) γ2, protein kinase C (PKC), and mitogen-activated protein kinases (MAPKs). It also inhibits in vivo thrombus formation in mice. In addition, neither the guanylate cyclase inhibitor ODQ nor the adenylate cyclase inhibitor SQ22536 affected the amarogentin-mediated inhibition of platelet aggregation, which suggests that amarogentin does not regulate the levels of cyclic AMP and cyclic GMP. In conclusion, amarogentin prevents platelet activation through the inhibition of PLC γ2-PKC cascade and MAPK pathway. Our findings suggest that amarogentin may offer therapeutic potential for preventing or treating thromboembolic disorders.

  11. Evaluation and application of a fast module in a PLC based interlock and control system

    International Nuclear Information System (INIS)

    Zaera-Sanz, M

    2009-01-01

    The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of μseconds. Siemens has introduced a 'so called' fast module (FM352-5 Boolean Processor). It provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This paper publishes the results of this study. As well, this paper could be useful for other applications requiring fast processing using a PLC.

  12. Nonmonotonic belief state frames and reasoning frames

    NARCIS (Netherlands)

    Engelfriet, J.; Herre, H.; Treur, J.

    1995-01-01

    In this paper five levels of specification of nonmonotonic reasoning are distinguished. The notions of semantical frame, belief state frame and reasoning frame are introduced and used as a semantical basis for the first three levels. Moreover, the semantical connections between the levels are

  13. 75 FR 27973 - Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines

    Science.gov (United States)

    2010-05-19

    ... RB211-524C2 Series Turbofan Engines AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice... Rolls-Royce plc (RR) model RB211-524C2-19 and RB211-524C2-B-19 turbofan engines. These engines are...

  14. Controlling the Filling and Capping Operation of a Bottling Plant using PLC and SCADA

    Directory of Open Access Journals (Sweden)

    Kunal Chakraborty

    2015-03-01

    Full Text Available This paper presents basic stages of operation of a bottling plant, i.e. the filling and capping process. The main aim of our paper is to control the filling and capping section of a bottling plant simultaneously. At first a set of empty bottle is run by using a conveyer towards filling section, after the operation, the filled bottles are sent towards the capping section. After successful capping operation, the sealed bottles terminate towards exit and a new set of empty bottle arrive, in this way the process continues. This paper includes the method using which, a bunch of bottles can be filled and capped at one instant of time. This method has made the operation more flexible and time saving. The filling and capping operations are controlled using Programmable Logic Controllers (PLC, as the PLC’s are very much user-efficient, cost-effective and easy to control. By using PLC automation the whole process is kept under control. SCADA (Supervisory Control and Data Acquisition is used to monitor the process by means of a display system.

  15. The Tributary Regime in the oil sector

    International Nuclear Information System (INIS)

    Carta Petrolera

    1998-01-01

    The tributary regime of the oil sector, is framed by the fiscal crisis that the country, maxim if one keeps in mind the importance of the fiscal revenues originated in the exploitation of these resources in Colombia, so much for the tribute coming from the foreign investment of the sector, like for the utilities generated by ECOPETROL and its impact in the public finances. However in front of this focus, the strategic importance of maintaining the investment in hydrocarbons and the paper that the fiscal politics and the tributary politics for the sector should play in the future and they constitute the government's key pieces

  16. 78 FR 65313 - Actavis, Inc. a corporation, and Warner Chilott PLC; Analysis of Agreement Containing Consent...

    Science.gov (United States)

    2013-10-31

    ... FEDERAL TRADE COMMISSION [File No. 131 0152] Actavis, Inc. a corporation, and Warner Chilott PLC... https://ftcpublic.commentworks.com/ftc/actaviswarnerconsent following the instructions on the web-based....com/ftc/actaviswarnerconsent by following the instructions on the web-based form. If this Notice...

  17. PC clusters at CERN's PC farm

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    These Linux-based PC clusters are mainly used for batch and interactive data processing. When the LHC starts operation in 2008, it will produce enough data every year to fill a stack of CDS 20 km tall, so high quality processing is required. To further facilitate this the LHC Computing Grid (LCG) has been set up to share processing power between facilities around the world.

  18. Plant phospholipase C family: Regulation and functional role in lipid signaling.

    Science.gov (United States)

    Singh, Amarjeet; Bhatnagar, Nikita; Pandey, Amita; Pandey, Girdhar K

    2015-08-01

    Phospholipase C (PLC), a major membrane phospholipid hydrolyzing enzyme generates signaling messengers such as diacylglycerol (DAG) and inositol 1,4,5-trisphosphate (IP3) in animals, and their phosphorylated forms such as phosphatidic acid (PA) and inositol hexakisphosphate (IP6) are thought to regulate various cellular processes in plants. Based on substrate specificity, plant PLC family is sub-divided into phosphatidylinositol-PLC (PI-PLC) and phosphatidylcholine-PLC (PC-PLC) groups. The activity of plant PLCs is regulated by various factors and the major ones include, Ca(2+) concentration, phospholipid substrate, post-translational modifications and interacting proteins. Most of the PLC members have been localized at the plasma membrane, suited for their function of membrane lipid hydrolysis. Several PLC members have been implicated in various cellular processes and signaling networks, triggered in response to a number of environmental cues and developmental events in different plant species, which makes them potential candidates for genetically engineering the crop plants for stress tolerance and enhancing the crop productivity. In this review article, we are focusing mainly on the plant PLC signaling and regulation, potential cellular and physiological role in different abiotic and biotic stresses, nutrient deficiency, growth and development. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. PC Mobile Warrior with a built-in cellular phone; Keitai denwa naizogata PC 'Mobile warrior

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    A PC Mobile Warrior with a built-in cellular phone has been developed from PC Libretto through cooperation with the NTT DoCoMo. The new personal computer incorporates into itself some distinguished mobile PC features such as Wake On Radio and Wake On Ring which are defined by MCPC (Mobile Computing Promotion Consortium). Wake On Radio is a function that activates the PC upon entry into the zone from outside, and Wake On Ring is another function that does the same upon arrival of a phone call. Installed on these lower order functions are an application program for automatic transmission of stored e-mails making use of the former function and another for automatic reception of FAX messages making use of the latter function. (translated by NEDO)

  20. PC Pricer

    Data.gov (United States)

    U.S. Department of Health & Human Services — The PC Pricer is a tool used to estimate Medicare PPS payments. The final payment may not be precise to how payments are determined in the Medicare claims processing...

  1. ELIPGRID-PC: A PC program for calculating hot spot probabilities

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1994-10-01

    ELIPGRID-PC, a new personal computer program has been developed to provide easy access to Singer's 1972 ELIPGRID algorithm for hot-spot detection probabilities. Three features of the program are the ability to determine: (1) the grid size required for specified conditions, (2) the smallest hot spot that can be sampled with a given probability, and (3) the approximate grid size resulting from specified conditions and sampling cost. ELIPGRID-PC also provides probability of hit versus cost data for graphing with spread-sheets or graphics software. The program has been successfully tested using Singer's published ELIPGRID results. An apparent error in the original ELIPGRID code has been uncovered and an appropriate modification incorporated into the new program

  2. Media Framing

    DEFF Research Database (Denmark)

    Pedersen, Rasmus T.

    2017-01-01

    The concept of media framing refers to the way in which the news media organize and provide meaning to a news story by emphasizing some parts of reality and disregarding other parts. These patterns of emphasis and exclusion in news coverage create frames that can have considerable effects on news...... consumers’ perceptions and attitudes regarding the given issue or event. This entry briefly elaborates on the concept of media framing, presents key types of media frames, and introduces the research on media framing effects....

  3. Test specification for decant pump and winch assembly

    International Nuclear Information System (INIS)

    Staehr, T.W.

    1994-01-01

    This specification provides the requirements for testing of the vertical turbine decant pump including the floating suction arm with load sensing winch control, instrumentation and the associated PLC/PC control system

  4. Framing effects over time: comparing affective and cognitive news frames

    NARCIS (Netherlands)

    Lecheler, S.; Matthes, J.

    2012-01-01

    A growing number of scholars examine the duration of framing effects. However, duration is likely to differ from frame to frame, depending on how strong a frame is. This strength is likely to be enhanced by adding emotional components to a frame. By means of an experimental survey design (n = 111),

  5. PrPC from stem cells to cancer

    Directory of Open Access Journals (Sweden)

    Séverine eMartin-Lannerée

    2014-09-01

    Full Text Available The cellular prion protein PrPC was initially discovered as the normal counterpart of the pathological scrapie prion protein PrPSc, the main component of the infectious agent of Transmissible Spongiform Encephalopathies. While clues as to the physiological function of this ubiquitous protein were greatly anticipated from the development of knock-out animals, PrP-null mice turned out to be viable and to develop without major phenotypic abnormalities. Notwithstanding, the discovery that hematopoietic stem cells from PrP-null mice have impaired long-term repopulating potential has set the stage for investigating into the role of PrPC in stem cell biology. A wealth of data have now exemplified that PrPC is expressed in distinct types of stem cells and regulates their self-renewal as well as their differentiation potential. A role for PrPC in the fate restriction of embryonic stem cells has further been proposed. Paralleling these observations, an overexpression of PrPC has been documented in various types of tumours. In line with the contribution of PrPC to stemness and to the proliferation of cancer cells, PrPC was recently found to be enriched in subpopulations of tumour-initiating cells. In the present review, we summarize the current knowledge of the role played by PrPC in stem cell biology and discuss how the subversion of its function may contribute to cancer progression.

  6. 76 FR 25353 - Hikma Pharmaceuticals PLC; Analysis of Agreement Containing Consent Orders To Aid Public Comment

    Science.gov (United States)

    2011-05-04

    ... FEDERAL TRADE COMMISSION [File No. 111 0051] Hikma Pharmaceuticals PLC; Analysis of Agreement...-based form. To ensure that the Commission considers an electronic comment, you must file it on the Web-based form at the Web link: https://ftcpublic.commentworks.com/ftc/hikmabaxter . If this Notice appears...

  7. The readout performance evaluation of PowerPC

    International Nuclear Information System (INIS)

    Chu Yuanping; Zhang Hongyu; Zhao Jingwei; Ye Mei; Tao Ning; Zhu Kejun; Tang Suqiu; Guo Yanan

    2003-01-01

    PowerPC, as a powerful low-cost embedded computer, is one of the very important research objects in recent years in the project of BESIII data acquisition system. The researches on the embedded system and embedded computer have achieved many important results in the field of High Energy Physics especially in the data acquisition system. The one of the key points to design an acquisition system using PowerPC is to evaluate the readout ability of PowerPC correctly. The paper introduce some tests for the PowerPC readout performance. (authors)

  8. PLC SCADA systém pro řízení větrného tunelu

    OpenAIRE

    Trenčan, Tomáš

    2017-01-01

    Předložená bakalářská práce se věnuje programovatelnému automatu (PLC) firmy WAGO a SCADA systémům. Skládá se ze dvou části, z teoretické části a z praktické části. V teoretické části jsou na zakladě poznatků z odborné literatury vymezeny pojmy ohledně SCADA systémů, PLC od firmy WAGO a vývojového prostředí e!COCKPIT firmy WAGO a rešerše volně dostupných SCADA systémů podporujících Modbus TCP. Na základě této rešerše byl vybrán SCADA systém pro vizualizaci dvou demonstračníc úloh v praktické ...

  9. Crystallization, optimization and preliminary X-ray characterization of a metal-dependent PI-PLC from Streptomyces antibioticus

    International Nuclear Information System (INIS)

    Jackson, Michael R.; Selby, Thomas L.

    2012-01-01

    Crystallization and diffraction analysis of a Ca 2+ -dependent PI-PLC from Streptomyces is reported. Optimization of crystals was completed using a drop-pinning technique and heavy-atom soaks to achieve high-quality diffraction to 1.23 Å. A recombinant metal-dependent phosphatidylinositol-specific phospholipase C (PI-PLC) from Streptomyces antibioticus has been crystallized by the hanging-drop method with and without heavy metals. The native crystals belonged to the orthorhombic space group P222, with unit-cell parameters a = 41.26, b = 51.86, c = 154.78 Å. The X-ray diffraction results showed significant differences in the crystal quality of samples soaked with heavy atoms. Additionally, drop pinning, which increases the surface area of the drops, was also used to improve crystal growth and quality. The combination of heavy-metal soaks and drop pinning was found to be critical for producing high-quality crystals that diffracted to 1.23 Å resolution

  10. 75 FR 15321 - Airworthiness Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines

    Science.gov (United States)

    2010-03-29

    ... Directives; Rolls-Royce plc RB211-Trent 800 Series Turbofan Engines AGENCY: Federal Aviation Administration... Based on the service information, we estimate that this AD will affect about 138 RB211 Trent 800 series... will cost about $2,000 per engine. Based on these figures, we estimate the cost of the AD on U.S...

  11. PLC-Based Pressure Control in Multi-Pump Applications

    Directory of Open Access Journals (Sweden)

    Vodovozov Valery

    2015-12-01

    Full Text Available The paper is devoted to the centrifugal pumps represented the most popular type of pumping equipment used in different areas. The pressure control approach for variable speed driven (VSD parallel connected centrifugal pumps is reported. The goal of the study is optimization of some quality indices, such as efficiency, consumed power, productivity, energy carrier temperature, heat irradiation, etc. One of them – efficiency – has been studied in the paper more carefully. The mathematical model of pumping process is discussed and a vector-matrix description of the multi-pump application is given. The program-based pressure control system is developed which productivity is changed by regulating the number of working pumps. The paper introduces new pressure control algorithms based on the working point estimation intended for programmable logical controllers (PLC. Experiments prove correctness of the offered methodology.

  12. Probing long-range structural order in SnPc/Ag(111) by umklapp process assisted low-energy angle-resolved photoelectron spectroscopy

    Science.gov (United States)

    Jauernik, Stephan; Hein, Petra; Gurgel, Max; Falke, Julian; Bauer, Michael

    2018-03-01

    Laser-based angle-resolved photoelectron spectroscopy is performed on tin-phthalocyanine (SnPc) adsorbed on silver Ag(111). Upon adsorption of SnPc, strongly dispersing bands are observed which are identified as secondary Mahan cones formed by surface umklapp processes acting on photoelectrons from the silver substrate as they transit through the ordered adsorbate layer. We show that the photoemission data carry quantitative structural information on the adsorbate layer similar to what can be obtained from a conventional low-energy electron diffraction (LEED) study. More specifically, we compare photoemission data and LEED data probing an incommensurate-to-commensurate structural phase transition of the adsorbate layer. Based on our results we propose that Mahan-cone spectroscopy operated in a pump-probe configuration can be used in the future to probe structural dynamics at surfaces with a temporal resolution in the sub-100-fs regime.

  13. Implementasi Penggunaan Smartphone Android untuk Control PC (Personal Computer

    Directory of Open Access Journals (Sweden)

    Imam Solikin

    2018-05-01

    Full Text Available The purpose of this research is to simplify the control of personal computer (PC such as control pointer, keyboard control and make it easier to do the presentation by controlling the slide remotely using smartphone through wifi connections facility. The smartphone is a multimedia phone that combines PC functionality with microprocessor, memory, and built-in modem to produce smart smartphone gadgets. Problems that occur when performing a presentation such as PC control, control pointer and keyboard control for input should be close to the PC so it is less than optimal in explaining the material. The model used in implementing the use of Android Smartphone for PC control is a conceptual model consisting of several stages: potential and problems, data collection, system testing, test results, and system implementation or implementation. From the results of PC control research can be done by connecting the Smartphone with a PC via wifi network so that PC can be controlled remotely. PC control application is an application that can control PC remotely connected via wifi network connection. Benefits derived from this research make it easy to mengedalikan PC remotely such as facilitate in the percentage and control pointer and control Keyboard for input process.

  14. Riesz frames and approximation of the frame coefficients

    DEFF Research Database (Denmark)

    Casazza, P.; Christensen, Ole

    1998-01-01

    A frame is a fmaily {f i } i=1 ∞ of elements in a Hilbert space with the property that every element in can be written as a (infinite) linear combination of the frame elements. Frame theory describes how one can choose the corresponding coefficients, which are called frame coefficients. From...... the mathematical point of view this is gratifying, but for applications it is a problem that the calculation requires inversion of an operator on . The projection method is introduced in order to avoid this problem. The basic idea is to consider finite subfamilies {f i } i=1 n of the frame and the orthogonal...... projection Pn onto its span. For has a representation as a linear combination of fi, i=1,2,..., n and the corresponding coefficients can be calculated using finite dimensional methods. We find conditions implying that those coefficients converge to the correct frame coefficients as n→∞, in which case we have...

  15. Development of a measurement and control system for a 10 kW@20 K refrigerator based on Siemens PLC S7-300

    Science.gov (United States)

    Li, J.; Liu, L. Q.; Liu, T.; Xu, X. D.; Dong, B.; Lu, W. H.; Pan, W.; Wu, J. H.; Xiong, L. Y.

    2017-02-01

    A 10 kW@20 K refrigerator has been established by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this 10 kW@20 K refrigerator is developed. According to the detailed measurement requirements, proper sensors and transmitters are adopted. Siemens S7-300 PLC CPU315-2 PN/DP operates as a master station. Two sets of ET200M DP remote expand I/O, one power meter, two compressors and one vacuum gauge operate as slave stations. Profibus-DP field communication and Modbus communication are used between the master station and the slave stations in this control system. The upper computer HMI (Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. After commissioning, this refrigerator has been operating with a 10 kW of cooling power at 20 K for more than 72 hours.

  16. Frames of exponentials:lower frame bounds for finite subfamilies, and approximation of the inverse frame operator

    DEFF Research Database (Denmark)

    Christensen, Ole; Lindner, Alexander M

    2001-01-01

    We give lower frame bounds for finite subfamilies of a frame of exponentials {e(i lambdak(.))}k is an element ofZ in L-2(-pi,pi). We also present a method for approximation of the inverse frame operator corresponding to {e(i lambdak(.))}k is an element ofZ, where knowledge of the frame bounds for...

  17. Installation and implementation of PC COSYMA; PC COSYMAn kaeyttoeoenotto ja soveltaminen

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, J [VTT Energy, Espoo (Finland). Nuclear Energy

    1995-12-01

    COSYMA is a probabilistic reactor accident consequence assessment model developed in the 1980`s by the research institutes of the EC countries, primarily by NRPB and KfK. In 1993 a simplified version of the program was released to be implemented on a PC. In the study the PC COSYMA program was applied to calculate as the end points nuclide concentrations, doses received, numbers of health effects, areas affected by countermeasures and other results related to countermeasure strategies. Some results are compared with the results obtained by the ARANO program developed by VTT Energy (Technical Research Centre of Finland) to quarantee proper interpretation of the application. (15 refs.).

  18. Effective time management for high performance in an organization Case: Lasaco Assurance PLC

    OpenAIRE

    Adeojo, Adeyinka

    2012-01-01

    The main objective of this thesis is to determine the effect of time management on high organizational performance using LASACO ASSURANCE Plc. as a case company. In this thesis, the employees working with the company were sent questionnaires. Their responses were critically analyzed and thus related to the theories. A quantitative approach was used as the methodology. According to the theory, time management is a method for managers to increase work performance effectiveness. Time man...

  19. Increase in Multicast OFDM Data Rate in PLC Network using Adaptive LP-OFDM

    OpenAIRE

    Maiga , Ali; Baudais , Jean-Yves; Hélard , Jean-François

    2009-01-01

    ISBN: 978-1-4244-3523-4; International audience; Linear precoding (LP) technique applied to OFDM systems has already proved its ability to significantly increase the system throughput in a powerline communication (PLC) context. In this paper, we propose resource allocation algorithms based on the LP technique to increase the multicast OFDM systems bit rate. The conventional multicast capacity is limited by the user which experiences the worst channel conditions. To increase the multicast bit ...

  20. High-speed narrowband PLC - High-performance Access Powerline Communication structures in smart grid; High-Speed Narrowband PLC. Leistungsfaehige Access-Powerline-Kommunikationsstrukturen im Smart Grid

    Energy Technology Data Exchange (ETDEWEB)

    Offner, Georg [devolo AG, Aachen (Germany)

    2012-07-01

    The smart grid provides a stable operation of a decentralized power system which is fed more and more by small providers by means of solar technology and wind power technology. Furthermore, commercial and private clients profit from the smart grid, as they may capture information about their current consumption in real time or can obtain these data from the Internet. The author of the contribution under consideration presents new approaches to access powerline communications that enable efficient communication between IPv6 based household meter and network station. The contribution under consideration describes the technologies used as well as practical experiences and initial results from field tests. Here insights from the integration of G3-PLC are in the foreground.

  1. PC application in DIII-D neutral beam operation

    International Nuclear Information System (INIS)

    Gladd, A.S.

    1986-01-01

    An IBM PC/AT has been implemented to improve operation of the DIII-D neutral beams. The PC system provides centralization of all beam data with reasonable access for online shot-to-shot control and analysis. The PC hardware was configured to interface all four neutral beam host mini-computers, support multi-tasking, and provide storage for approximately one month's accumulation of beam data. The PC software is composed of commercial packages used for performance and statistical analysis (i.e. LOTUS 123, PC PLOT, etc.) host communications software (i.e. PCLINK, KERMIT, etc.) and applications developed software utilizing FORTRAN and BASIC. The objectives of this paper are to describe the implementation of the PC system, the methods of integrating the various software packages, and the scenario for online control and analysis

  2. Development of a Measurement and Control System for a 40l/h Helium Liquefier based on Siemens PLC S7-300

    Science.gov (United States)

    Li, J.; Liu, L. Q.; Xu, X. D.; Liu, T.; Li, Q.; Hu, Z. J.; Wang, B. M.; Xiong, L. Y.; Dong, B.; Yan, T.

    A 40l/h Helium Liquefier has been commissioned by the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. A measurement and control system based on Siemens PLC S7-300 for this Helium Liquefier is developed. Proper sensors are selected, for example, three types of transmitters are adopted respectively according to detailed temperature measurement requirements. Siemens S7-300 PLC CPU315-2PN/DP operates as a master station and three sets of ET200 M DP remote expand I/O operate asslave stations. Profibus-DP field communication is used between the master station and the slave stations. The upper computer HMI(Human Machine Interface) is compiled using Siemens configuration software WinCC V7.0. The upper computer communicates with PLC by means of industrial Ethernet. A specific control logic for this Helium Liquefier is developed. The control of the suction and discharge pressures of the compressor and the control of the turbo-expanders loop are being discussed in this paper. Following the commissioning phase, the outlet temperature of the second stage turbine has reached 8.6K and the temperature before the throttle valve has reached 13.1K.

  3. Prime tight frames

    DEFF Research Database (Denmark)

    Lemvig, Jakob; Miller, Christopher; Okoudjou, Kasso A.

    2014-01-01

    to suggest effective analysis and synthesis computation strategies for such frames. Finally, we describe all prime frames constructed from the spectral tetris method, and, as a byproduct, we obtain a characterization of when the spectral tetris construction works for redundancies below two.......We introduce a class of finite tight frames called prime tight frames and prove some of their elementary properties. In particular, we show that any finite tight frame can be written as a union of prime tight frames. We then characterize all prime harmonic tight frames and use thischaracterization...

  4. Linguistic Justice for which Demos? The Democratic Legitimacy of Language Regime Choices

    Directory of Open Access Journals (Sweden)

    Garcia Núria

    2016-10-01

    Full Text Available In the European Union language regime debate, theorists of multiculturalism and cosmopolitanism have framed their arguments in reference to different theories of justice and democracy. Philippe Van Parijs advocates the diffusion of a lingua franca, namely English, as means of changing the scale of the justificatory community to the European level and allowing the creation of a transnational demos. Paradoxically, one key dimension of democracy has hardly been addressed in this discussion: the question of the democratic legitimacy of language regime choices and citizens’ preferences on the different language regime scenarios. Addressing the question of the congruence of language policy choices operated by national and European elites and ordinary citizens’ preferences, this paper argues first that the dimension of democratic legitimacy is crucial and needs to be taken into account in discussions around linguistic justice. Criticizing the assumption of a direct correspondence between individuals’ language learning choices and citizens’ language regime preferences made by different authors, the analysis shows the ambivalence of citizens’ preferences measured by survey data. The article secondly raises the question of the boundaries of the political community at which the expression of citizens’ preferences should be measured and demonstrates that the outcome and the fairness of territorial linguistic regimes may vary significantly according to the level at which this democratic legitimacy is taken into account.

  5. Construction method with prestressed connection of precast prestressed concrete using composite slab with multi-round opening web. Bibai factory office building of Dopi Kensetsu Kogyo Co; Web bu ni renzoku enkei kaiko wo yusuru PC gosei yukaita wo mochiita PC kumitate koho. Dopi kensetsu kogyo (kabu) Bibai kojo jimushoto shinchiku koji

    Energy Technology Data Exchange (ETDEWEB)

    Kuramochi, H.; Nakai, J.; Arai, S.; Toriya, T.

    1997-07-31

    This report summarizes the experimental result on the structural performance of precast prestressed concrete (PC) composite slab work, and a construction method with prestressed connection of PC. Although a double T type precast PC slab (DT board) is frequently used as buried form for slabs, it requires extremely complex bar arrangement and complicated works. The reinforcement method of supports using deformed hair pin type bars was thus devised which has a structural performance higher than that of the previous methods as well as simple bar arrangement and superior workability. For the reinforced DT board (DP slab) and the composite slab construction method using the DP slab, the structural safety and retained use environment were confirmed by structural performance test and construction test. The foundation and footing beam of the Bibai factory office building were constructed by the conventional method considering the construction method, while the column, beam and floor by this method using PCa members. The upper building frame was thus completed for as short as 23 days. 5 refs., 15 figs., 4 tabs.

  6. Quantum frames

    Science.gov (United States)

    Brown, Matthew J.

    2014-02-01

    The framework of quantum frames can help unravel some of the interpretive difficulties i the foundation of quantum mechanics. In this paper, I begin by tracing the origins of this concept in Bohr's discussion of quantum theory and his theory of complementarity. Engaging with various interpreters and followers of Bohr, I argue that the correct account of quantum frames must be extended beyond literal space-time reference frames to frames defined by relations between a quantum system and the exosystem or external physical frame, of which measurement contexts are a particularly important example. This approach provides superior solutions to key EPR-type measurement and locality paradoxes.

  7. In search of the creation of news frames in Flemish newspapers: The case of the Belgian ‘Syria warriors’

    NARCIS (Netherlands)

    Boesman, J.L.J.; Berbers, A.; d'Haenens, L.; Van Gorp, B.

    2014-01-01

    This paper investigates the framing construction of Flemish newspaper journalists regarding the so-called ‘Syria-warriors’. When the Syrian conflict developed, the rebels against the Assad regim were joined by young muslims from Western European countries. Figures of the number of Belgian fighters

  8. Frame scaling function sets and frame wavelet sets in Rd

    International Nuclear Information System (INIS)

    Liu Zhanwei; Hu Guoen; Wu Guochang

    2009-01-01

    In this paper, we classify frame wavelet sets and frame scaling function sets in higher dimensions. Firstly, we obtain a necessary condition for a set to be the frame wavelet sets. Then, we present a necessary and sufficient condition for a set to be a frame scaling function set. We give a property of frame scaling function sets, too. Some corresponding examples are given to prove our theory in each section.

  9. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    Energy Technology Data Exchange (ETDEWEB)

    Li, J.; Xiong, L. Y.; Peng, N.; Dong, B.; Liu, L. Q. [Key Laboratory of Cryogenics, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing, 100190 (China); Wang, P. [Beijing Sciample Technology Co., Ltd., Beijing, 100190 (China)

    2014-01-29

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

  10. Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

    Science.gov (United States)

    Li, J.; Xiong, L. Y.; Peng, N.; Dong, B.; Wang, P.; Liu, L. Q.

    2014-01-01

    An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

  11. Application of high-frame-rate neutron radiography to fluid measurement

    International Nuclear Information System (INIS)

    Mishima, Kaichiro; Hibiki, Takashi

    1997-01-01

    To apply Neutron radiography (NR) technique to multiphase flow research, high frame-rate NR was developed by assembling up-to-date technologies for neutron source, scintillator, high-speed video and image intensifier. This imaging system has several advantages such as a long recording time (up to 21 minutes), high-frame-rate (up to 1000 frames/s) imaging and no need for triggering signal. Visualization studies of air-water two-phase flow in a metallic duct and molten metal-water interaction were performed at the recording speeds of 250, 500 and 1000 frames/s. The qualities of those consecutive images were good enough to observe the flow pattern and behavior. It was demonstrated also that some characteristics of two-phase flow could be measured from those images in collaboration with image processing techniques. By utilizing geometrical information extracted from NR images, data on flow regime, rising velocity of bubbles, and wave height and interfacial area in annular flow could be obtained. By utilizing attenuation characteristics of neutrons in materials, measurements of void profile and average void fraction could be performed. For this purpose, a quantification method, i.e. Σ-scaling method, was proposed based upon the consideration on the effect of scattered neutrons. This method was tested against known void profiles and compared with existing measurement methods and a correlation for void fraction. It was confirmed that this new technique has significant advantages both in visualizing and measuring high-speed fluid phenomena. (J.P.N.)

  12. Institutional radioactive waste management in the Nuclear Research Institute Rez plc

    International Nuclear Information System (INIS)

    Kovarik, P.; Svoboda, K.; Podlaha, J.

    2008-01-01

    Nuclear research institute Rez, plc. (mentioned below as NRI) has had a dominant position in the area of the nuclear research and development in the Czech Republic, the Central and the Eastern Europe. Naturally, the radioactive waste management is an integral part of the nuclear industry, research and development. For that reason, there is Centre of the radioactive waste management (mentioned below as Centre) in the NRI. This Centre is engaged in the radioactive waste treatment, decontamination, characterisation, decommissioning and other relevant activities. This paper describes the system of technology and other information about institutional radioactive waste management in the NRI. (authors)

  13. The comparison of CAP88-PC version 2.0 versus CAP88-PC version 1.0

    International Nuclear Information System (INIS)

    Yakubovich, B.A.; Klee, K.O.; Palmer, C.R.; Spotts, P.B.

    1997-12-01

    40 CFR Part 61 (Subpart H of the NESHAP) requires DOE facilities to use approved sampling procedures, computer models, or other approved procedures when calculating Effective Dose Equivalent (EDE) values to members of the public. Currently version 1.0 of the approved computer model CAP88-PC is used to calculate EDE values. The DOE has upgraded the CAP88-PC software to version 2.0. This version provides simplified data entry, better printing characteristics, the use of a mouse, and other features. The DOE has developed and released version 2.0 for testing and comment. This new software is a WINDOWS based application that offers a new graphical user interface with new utilities for preparing and managing population and weather data, and several new decay chains. The program also allows the user to view results before printing. This document describes a test that confirmed CAP88-PC version 2.0 generates results comparable to the original version of the CAP88-PC program

  14. Úzkopásmová PLC komunikace s vysokou datovou rychlostí na bázi OFDM techniky

    OpenAIRE

    Csiba, Patrik

    2015-01-01

    Tato bakalářská práce se zabývá úzkopásmovou PLC komunikací. V práci je popisována historie, princip úzkopásmové komunikace a popis čtyř dostupných úzkopásmových standardů (PRIME, G3-PLC, G.hnem, IEEE P1901.2) s jejich porovnáním. V další části jsou popisována experimentální měření, která jsou prováděna v domácím prostředí za použití dostupných modemů TMDSPLCKIT od firmy Texas Instruments, MT39-L1-ver.R modemů od firmy ModemTec a EVALKITST7580-1 od firmy STMicroelectronics. This bachelor p...

  15. Feature of extradosed PC bridge and its design; Daihenshin keburu PC kyo no tokucho to sono sekkei

    Energy Technology Data Exchange (ETDEWEB)

    Komiya, M. [Japan Bridge and Structure Institute Inc., Tokyo (Japan)

    1997-03-31

    A PC bridge with the eccentricity of the external cable increased by protruding the deviated member to the outside of the beam for more effective use of the external cable is called a `PC bridge with tendons of large eccentricity.` The extradosed bridge of main beam/cable joint type is a PC bridge with the external cable arranged via a tower-shaped eccentric member provided at the intermediate support, and resembles morphologically a cable stayed bridge having a very low tower. There are two types of extradosed bridges, i.e. a type with concrete coated external cable (cable stayed slab bridge) and the other with non-coated external cable (external cable stayed bridge). Features, structural planning and designing of the general external cable stayed bridge are shown. The features are the possession of intermediate characteristics of those of the PC beam bridge and the PC cable stayed bridge from the viewpoints of structural property, workability, economic efficiency, and scenic property. Outline of the plan, selection of structural data, design of the external cable, and structural characteristics in the ultimate state are discussed. 19 refs., 18 figs., 15 tabs.

  16. Business strategy and the environment Tesco Plc's declining financial performance and underlying issues

    OpenAIRE

    Haddock-Millar, Julie; Rigby, Chris

    2015-01-01

    The case presents a teaching tool which requires students to: 1) analyze the financial performance of Tesco Plc over the last four years; 2) compare Tesco’s market position with key competitors; 3) identify and evaluate Tesco’s business strategy; 4) evaluate the causes of Tesco’s decline in performance; 5) develop recommendations to address declining performance; 6) identify and evaluate the Human Resource strategic role in addressing and supporting performance. The case is suitable for a bus...

  17. Riesz Frames and Approximation of the Frame Coefficients

    DEFF Research Database (Denmark)

    Christensen, Ole

    1996-01-01

    A frame is a familyof elements in a Hilbert space with the propertythat every element in the Hilbert space can be written as a (infinite)linear combination of the frame elements. Frame theory describes howone can choose the corresponding coefficients, which are calledframe coefficients. From...... the mathematical point of view this isgratifying, but for applications it is a problem that the calculationrequires inversion of an operator on the Hilbert space.The projection method is introduced in order to avoid this problem.The basic idea is to consider finite subfamiliesof the frame and the orthogonal...... projection onto its span. Forfin QTR H,P_nf has a representation as a linear combinationof f_i,i=1,2,..,n, and the corresponding coefficients can be calculatedusing finite dimensional methods. We find conditions implying that thosecoefficients converge to the correct frame coefficients as n goes...

  18. Developing a PLC-friendly state machine model: lessons learned

    Science.gov (United States)

    Pessemier, Wim; Deconinck, Geert; Raskin, Gert; Saey, Philippe; Van Winckel, Hans

    2014-07-01

    Modern Programmable Logic Controllers (PLCs) have become an attractive platform for controlling real-time aspects of astronomical telescopes and instruments due to their increased versatility, performance and standardization. Likewise, vendor-neutral middleware technologies such as OPC Unified Architecture (OPC UA) have recently demonstrated that they can greatly facilitate the integration of these industrial platforms into the overall control system. Many practical questions arise, however, when building multi-tiered control systems that consist of PLCs for low level control, and conventional software and platforms for higher level control. How should the PLC software be structured, so that it can rely on well-known programming paradigms on the one hand, and be mapped to a well-organized OPC UA interface on the other hand? Which programming languages of the IEC 61131-3 standard closely match the problem domains of the abstraction levels within this structure? How can the recent additions to the standard (such as the support for namespaces and object-oriented extensions) facilitate a model based development approach? To what degree can our applications already take advantage of the more advanced parts of the OPC UA standard, such as the high expressiveness of the semantic modeling language that it defines, or the support for events, aggregation of data, automatic discovery, ... ? What are the timing and concurrency problems to be expected for the higher level tiers of the control system due to the cyclic execution of control and communication tasks by the PLCs? We try to answer these questions by demonstrating a semantic state machine model that can readily be implemented using IEC 61131 and OPC UA. One that does not aim to capture all possible states of a system, but rather one that attempts to organize the course-grained structure and behaviour of a system. In this paper we focus on the intricacies of this seemingly simple task, and on the lessons that we

  19. 75 FR 50877 - Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines

    Science.gov (United States)

    2010-08-18

    ... Airworthiness Directives; Rolls-Royce plc RB211-524C2 Series Turbofan Engines AGENCY: Federal Aviation... require adopting the AD as proposed. Costs of Compliance Based on the service information, we estimate.... Required parts will cost about $25,000 per product. Based on these figures, we estimate the cost of the AD...

  20. Building the perfect PC

    CERN Document Server

    Thompson, Robert Bruce

    2006-01-01

    This popular Build-It-Yourself (BIY) PC book covers everything you want to know about building your own system: Planning and picking out the right components, step-by-step instructions for assembling your perfect PC, and an insightful discussion of why you'd want to do it in the first place. Most big brand computers from HP, Dell and others use lower-quality components so they can meet their aggressive pricing targets. But component manufacturers also make high-quality parts that you can either purchase directly, or obtain through distributors and resellers. Consumers and corporations

  1. Frames and counter-frames giving meaning to dementia: a framing analysis of media content.

    Science.gov (United States)

    Van Gorp, Baldwin; Vercruysse, Tom

    2012-04-01

    Media tend to reinforce the stigmatization of dementia as one of the most dreaded diseases in western society, which may have repercussions on the quality of life of those with the illness. The persons with dementia, but also those around them become imbued with the idea that life comes to an end as soon as the diagnosis is pronounced. The aim of this paper is to understand the dominant images related to dementia by means of an inductive framing analysis. The sample is composed of newspaper articles from six Belgian newspapers (2008-2010) and a convenience sample of popular images of the condition in movies, documentaries, literature and health care communications. The results demonstrate that the most dominant frame postulates that a human being is composed of two distinct parts: a material body and an immaterial mind. If this frame is used, the person with dementia ends up with no identity, which is in opposition to the Western ideals of personal self-fulfilment and individualism. For each dominant frame an alternative counter-frame is defined. It is concluded that the relative absence of counter-frames confirms the negative image of dementia. The inventory might be a help for caregivers and other professionals who want to evaluate their communication strategy. It is discussed that a more resolute use of counter-frames in communication about dementia might mitigate the stigma that surrounds dementia. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Advanced control system for the scattering chamber of K-130 cyclotron

    International Nuclear Information System (INIS)

    Bhaumik, Tapas Kumar; Saha, Amiya Kumar; Mandal, Bidhan Chandra; Adak, Debabrata; Purkait, Monirul; Bhattacharya, Sailajananda

    2013-01-01

    The old relay based position control system of the Scattering Chamber of K-130 Cyclotron was more than 30 years old, developed multiple problems over the years, and the components of the control system like relays, potentiometers, limit switches, radiation resistant cables were not functioning as per specifications. It has been replaced recently by a new PLC based embedded control system. This has been developed using Advantech ADAM-5510EKW 16 bit CPU together with required I/O modules. MULTIPROG Basic V.4.6 has been used as programming software and Ladder Diagram has been used to realize control scheme of the PLC. A resistive type touch screen based operator panel, WebOP-2104VN4AE has been mounted on the control rack for local control. iFIX SCADA, 75 tags Runtime Version 5.1 has been used to operate from remote PC connected to the PLC by 70m CAT6 cable. The PLC communicates with the touch panel and remote PC through 100 Mbps Ethernet switch. The Graphical User Interfaces of the local control panel and the remote panel have been developed as per the requirement from the users. All the old sensors, limit switches, relays and cables have been replaced by new items. This paper reports about the development and commissioning of basic hardware, software and operation of the control system for last six months. (author)

  3. 78 FR 23316 - The Royal Bank of Scotland plc, et al.; Notice of Application and Temporary Order

    Science.gov (United States)

    2013-04-18

    ... plc, et al.; Notice of Application and Temporary Order April 12, 2013. AGENCY: Securities and Exchange Commission (``Commission''). ACTION: Temporary order and notice of application for a permanent order under... application for a permanent order. Applicants have also applied for a permanent order. APPLICANTS: The Royal...

  4. An eastward propagating compressional Pc 5 wave observed by AMPTE/CCE in the postmidnight sector

    International Nuclear Information System (INIS)

    Takahashi, K.; McEntire, R.W.; Zanetti, L.J.; Lopez, R.E.; Kistler, L.M.; Ipavich, R.M.

    1987-01-01

    Data from three instruments, the magnetometer, the charge-energy-mass spectrometer, and the medium-energy particle analyzer onboard the Active Magnetospheric Particle Tracer Explorers/Charge Composition Explorer (CCE) spacecraft have been used to study a compressional Pc 5 wave observed at 1925-2200 UT on day 202 (July 21) of 1986 at a radial distance of ≅ 8 R E in the postmidnight sector near the beginning of minor geomagnetic activity. The wave exhibited harmonically related transverse and compressional magnetic oscillations, modulation of the flux of medium energy protons (E approx-gt 10 keV), and a large azimuthal wave number (m ∼ 65). These properties are similar to those of compressional Pc 5 waves observed previously at geostationary orbit. The unique observations associated with the CCE event are the occurrence in the postmidnight sector, the eastward (or sunward) propagation with respect to the spacecraft, and the left-handed polarization of the perturbed magnetic field. These are opposite to previous geostationary observations. The authors propose that the unique propagation and polarization are propagating westward in the plasma rest frame, appears to propagate eastward to the observer because the electric field drift velocity is larger than the wave phase velocity

  5. Novel Networked Remote Laboratory Architecture for Open Connectivity Based on PLC-OPC-LabVIEW-EJS Integration. Application in Remote Fuzzy Control and Sensors Data Acquisition.

    Science.gov (United States)

    González, Isaías; Calderón, Antonio José; Mejías, Andrés; Andújar, José Manuel

    2016-10-31

    In this paper the design and implementation of a network for integrating Programmable Logic Controllers (PLC), the Object-Linking and Embedding for Process Control protocol (OPC) and the open-source Easy Java Simulations (EJS) package is presented. A LabVIEW interface and the Java-Internet-LabVIEW (JIL) server complete the scheme for data exchange. This configuration allows the user to remotely interact with the PLC. Such integration can be considered a novelty in scientific literature for remote control and sensor data acquisition of industrial plants. An experimental application devoted to remote laboratories is developed to demonstrate the feasibility and benefits of the proposed approach. The experiment to be conducted is the parameterization and supervision of a fuzzy controller of a DC servomotor. The graphical user interface has been developed with EJS and the fuzzy control is carried out by our own PLC. In fact, the distinctive features of the proposed novel network application are the integration of the OPC protocol to share information with the PLC and the application under control. The user can perform the tuning of the controller parameters online and observe in real time the effect on the servomotor behavior. The target group is engineering remote users, specifically in control- and automation-related tasks. The proposed architecture system is described and experimental results are presented.

  6. Novel Networked Remote Laboratory Architecture for Open Connectivity Based on PLC-OPC-LabVIEW-EJS Integration. Application in Remote Fuzzy Control and Sensors Data Acquisition

    Directory of Open Access Journals (Sweden)

    Isaías González

    2016-10-01

    Full Text Available In this paper the design and implementation of a network for integrating Programmable Logic Controllers (PLC, the Object-Linking and Embedding for Process Control protocol (OPC and the open-source Easy Java Simulations (EJS package is presented. A LabVIEW interface and the Java-Internet-LabVIEW (JIL server complete the scheme for data exchange. This configuration allows the user to remotely interact with the PLC. Such integration can be considered a novelty in scientific literature for remote control and sensor data acquisition of industrial plants. An experimental application devoted to remote laboratories is developed to demonstrate the feasibility and benefits of the proposed approach. The experiment to be conducted is the parameterization and supervision of a fuzzy controller of a DC servomotor. The graphical user interface has been developed with EJS and the fuzzy control is carried out by our own PLC. In fact, the distinctive features of the proposed novel network application are the integration of the OPC protocol to share information with the PLC and the application under control. The user can perform the tuning of the controller parameters online and observe in real time the effect on the servomotor behavior. The target group is engineering remote users, specifically in control- and automation-related tasks. The proposed architecture system is described and experimental results are presented.

  7. Novel Networked Remote Laboratory Architecture for Open Connectivity Based on PLC-OPC-LabVIEW-EJS Integration. Application in Remote Fuzzy Control and Sensors Data Acquisition

    Science.gov (United States)

    González, Isaías; Calderón, Antonio José; Mejías, Andrés; Andújar, José Manuel

    2016-01-01

    In this paper the design and implementation of a network for integrating Programmable Logic Controllers (PLC), the Object-Linking and Embedding for Process Control protocol (OPC) and the open-source Easy Java Simulations (EJS) package is presented. A LabVIEW interface and the Java-Internet-LabVIEW (JIL) server complete the scheme for data exchange. This configuration allows the user to remotely interact with the PLC. Such integration can be considered a novelty in scientific literature for remote control and sensor data acquisition of industrial plants. An experimental application devoted to remote laboratories is developed to demonstrate the feasibility and benefits of the proposed approach. The experiment to be conducted is the parameterization and supervision of a fuzzy controller of a DC servomotor. The graphical user interface has been developed with EJS and the fuzzy control is carried out by our own PLC. In fact, the distinctive features of the proposed novel network application are the integration of the OPC protocol to share information with the PLC and the application under control. The user can perform the tuning of the controller parameters online and observe in real time the effect on the servomotor behavior. The target group is engineering remote users, specifically in control- and automation-related tasks. The proposed architecture system is described and experimental results are presented. PMID:27809229

  8. First Experience with PLC, OPC and BridgeVIEW in the context of the HMPID liquid distribution prototype

    CERN Document Server

    Maatta, E; CERN. Geneva; Swoboda, Detlef; Lecoeur, G

    1999-01-01

    The TESt (Test and Evaluation Station) [3] project consists in the construction of a stand alone unit for a specific sub-system of an ALICE detector in order to gain first experience with commercial products for detector control. Although the control system includes only a small number of devices and is designed for a particular application, it covers nevertheless all layers of a complete system and can be extended or used in different applications. The control system prototype has been implemented for the Perfluorohexane (C6F14) liquid distribution of the ALICE-HMPID (High-Momentum Particle IDentification)[5]. This report presents the experience acquired while developing the control system with off the shelf items: National Instruments BridgeVIEW [6] supervision software, SIEMENS PLC S7-300 [7] and the programming tool STEP 7. The OPC standard (OLE [12] for Process Control) [8] was used for the communication between BridgeVIEW and the PLC.

  9. Body frames and frame singularities for three-atom systems

    International Nuclear Information System (INIS)

    Littlejohn, R.G.; Mitchell, K.A.; Aquilanti, V.; Cavalli, S.

    1998-01-01

    The subject of body frames and their singularities for three-particle systems is important not only for large-amplitude rovibrational coupling in molecular spectroscopy, but also for reactive scattering calculations. This paper presents a geometrical analysis of the meaning of body frame conventions and their singularities in three-particle systems. Special attention is devoted to the principal axis frame, a certain version of the Eckart frame, and the topological inevitability of frame singularities. The emphasis is on a geometrical picture, which is intended as a preliminary study for the more difficult case of four-particle systems, where one must work in higher-dimensional spaces. The analysis makes extensive use of kinematic rotations. copyright 1998 The American Physical Society

  10. How Different Newspapers Cover Xingjian Conflicts from Human Right Perspective? A Frame Analysis of 10 Newspapers from Taiwan, Hong Kong, Mainland China, Britain and Unites States

    Directory of Open Access Journals (Sweden)

    Chin-Hwa Chang

    2015-11-01

    Full Text Available Drastic increase of riots has been noted in Xingjian, the far-western Chinese region, in recent years, resulting in international media concerns about its ethnic conflicts, terrorism and human rights abuses. How different newspapers covered those conflict events from the human rights perspective? The paper aims to analyze different news frames of 10 newspapers: 4 major Taiwan newspapers, 2 China’s major newspapers, 2 Hong Kong newspapers, New York Times of US and The Guardian in Britain. Adopting a content analysis of 7 major Xingjian riots coverage during 2013/06 to 2013/12, the research finds out that there are 2 major frames, one is the China official frame, which shows less news sources with one-sided pro-regime position, accusing the protesters, concerning less human rights abuses. While the “critical frame” demonstrates more news sources from different positions, accusing both the regime and the protesters, and covering more human rights abuses.

  11. Frame on frames: an annotated bibliography

    International Nuclear Information System (INIS)

    Wright, T.; Tsao, H.J.

    1983-01-01

    The success or failure of any sample survey of a finite population is largely dependent upon the condition and adequacy of the list or frame from which the probability sample is selected. Much of the published survey sampling related work has focused on the measurement of sampling errors and, more recently, on nonsampling errors to a lesser extent. Recent studies on data quality for various types of data collection systems have revealed that the extent of the nonsampling errors far exceeds that of the sampling errors in many cases. While much of this nonsampling error, which is difficult to measure, can be attributed to poor frames, relatively little effort or theoretical work has focused on this contribution to total error. The objective of this paper is to present an annotated bibliography on frames with the hope that it will bring together, for experimenters, a number of suggestions for action when sampling from imperfect frames and that more attention will be given to this area of survey methods research

  12. Organic photovoltaic effects depending on CuPc layer thickness

    International Nuclear Information System (INIS)

    Hur, Sung Woo; Kim, Tae Wan; Chung, Dong Hoe; Oh, Hyun Seok; Kim, Chung Hyeok; Lee, Joon Ung; Park, Jong Wook

    2004-01-01

    Organic photovoltaic effects were studied in device structures of ITO/CuPc/Al and ITO/CuPc/C 60 /BCP/Al by varying the CuPc layer thickness. Since the exciton diffusion length is relatively short in organic semiconductors, a study on the thickness-dependent photovoltaic effects is important. The thickness of the CuPc layer was varied from 10 nm to 50 nm. We found that the optimum CuPc layer thickness was around 40 nm from the analysis of the current density-voltage characteristics in an ITO/CuPc/Al photovoltaic cell. The efficiency of the device shows that the multi-layered heterojunction structure is more appropriate for photovoltaic cells.

  13. 75 FR 28655 - Rexam Closure Systems, Inc. a Subsidiary of Rexam PLC Including On-Site Leased Workers From...

    Science.gov (United States)

    2010-05-21

    ... Hamlet, NC; Amended Certification Regarding Eligibility To Apply for Worker Adjustment Assistance In..., applicable to the workers of Rexam Closure Systems, Inc., a subsidiary of Rexam PLC, Hamlet, North Carolina... paid through Owens Illinois Manufacturing, Hamlet, North Carolina, who became totally or partially...

  14. Based on the Hardware Resources Configurable Shanke PLC Building Energy Consumption Detection System

    Directory of Open Access Journals (Sweden)

    Cheng Guanghe

    2017-01-01

    Full Text Available According to the actual situation of the comprehensive office building and the functional requirements of the building energy consumption monitoring and management system, the office building energy consumption monitoring and management system is designed by using the hardware resource configurable Shanke PLC(SKPLC as the data collector. The system uses data bus technology and field data acquisition technology to achieve the building energy consumption data acquisition and management. Practice has proved that energy-saving effect is good.

  15. Leo II PC

    Data.gov (United States)

    Kansas Data Access and Support Center — LEO II is a second-generation software system developed for use on the PC, which is designed to convert location references accurately between legal descriptions and...

  16. Surface-type nonvolatile electric memory elements based on organic-on-organic CuPc-H2Pc heterojunction

    International Nuclear Information System (INIS)

    Karimov, Khasan S.; Muqeet Rehman, M.; Zameer Abbas, S.; Ahmad, Zubair; Touati, Farid; Mahroof-Tahir, M.

    2015-01-01

    A novel surface-type nonvolatile electric memory elements based on organic semiconductors CuPc and H 2 Pc are fabricated by vacuum deposition of the CuPc and H 2 Pc films on preliminary deposited metallic (Ag and Cu) electrodes. The gap between Ag and Cu electrodes is 30–40 μm. For the current–voltage (I–V) characteristics the memory effect, switching effect, and negative differential resistance regions are observed. The switching mechanism is attributed to the electric-field-induced charge transfer. As a result the device switches from a low to a high-conductivity state and then back to a low conductivity state if the opposite polarity voltage is applied. The ratio of resistance at the high resistance state to that at the low resistance state is equal to 120–150. Under the switching condition, the electric current increases ∼ 80–100 times. A comparison between the forward and reverse I–V characteristics shows the presence of rectifying behavior. (paper)

  17. 160 Gb/s OFDM transmission utilizing an all-optical symbol generator based on PLC

    Science.gov (United States)

    Liang, Xiaojun; Qiao, Yaojun; Li, Wei; Mei, Junyao; Qin, Yi

    2009-11-01

    We demonstrate a 160 Gb/s orthogonal frequency division multiplexing (OFDM) system using an all-optical symbol generator based on planar light circuit (PLC) technology. Excellent bit error rate (BER) is observed after long-distance transmission. The proposed symbol generator fundamentally eliminates the processing speed limits introduced by electronics and is suitable for high integration, making it physically realizable to build high-speed all-optical OFDM systems with a large number of subcarriers.

  18. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    International Nuclear Information System (INIS)

    Baldaconi, Ricardo H.; Costa, Fabio E. da

    2017-01-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  19. Comparative response time and fault logging with a PLC and supervisory software and a standalone unit developed for recording

    Energy Technology Data Exchange (ETDEWEB)

    Baldaconi, Ricardo H., E-mail: ricardohovacker@hotmail.com [Escola Senai Roberto Simonsen, Educação e Tecnologia, Sao Paulo, SP (Brazil); Costa, Fabio E. da, E-mail: fecosta@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    The Cobalt-60 irradiator of IPEN / CNEN, a category IV facility, has a security system for inter locking doors or exposure of radioactive sources made simultaneously by a programmable logic controller (PLC) model S7-200 from Siemens and a relay logic. From a set of information, both systems work together opening doors or exposing the sources. All incoming and outgoing information are sent serially via EIA232 communication to a personal computer with Windows® platform for a supervisory program which provides the monitoring of the entire process by a synoptic table on the computer screen and is also intended to keep records of all events on the computer's hard drive. A deficiency was found for the process of sending events via serial communication (EIA232) from PLC to the supervisory program. When failure occurred in a very short time, the PLC always took the right decision, but the registration process that had to go through the Windows® timeshare lost the information. In the previous work developed a standalone electronics unit connected to the inputs and outputs of the security system, fully optocoupled to avoid any interference to the security system that records each event on a memory card. In this work, for checking the unit developed record time ability, transients incoming signals for simulating failures, were injected at security system inputs and the response time of security system, supervisory program and the autonomous unity were measured and compared. (author)

  20. Nonlinear analysis of the progressive collapse of reinforced concrete plane frames using a multilayered beam formulation

    Directory of Open Access Journals (Sweden)

    C. E. M. Oliveira

    Full Text Available This work investigates the response of two reinforced concrete (RC plane frames after the loss of a column and their potential resistance for progressive collapse. Nonlinear dynamic analysis is performed using a multilayered Euler/Bernoulli beam element, including elasto-viscoplastic effects. The material nonlinearity is represented using one-dimensional constitutive laws in the material layers, while geometrical nonlinearities are incorporated within a corotational beam formulation. The frames were designed in accordance with the minimum requirements proposed by the reinforced concrete design/building codes of Europe (fib [1-2], Eurocode 2 [3] and Brazil (NBR 6118 [4]. The load combinations considered for PC analysis follow the prescriptions of DoD [5]. The work verifies if the minimum requirements of the considered codes are sufficient for enforcing structural safety and robustness, and also points out the major differences in terms of progressive collapse potential of the corresponding designed structures.

  1. Buoyancy-driven chaotic regimes during solute dispersion in pore networks

    International Nuclear Information System (INIS)

    Tsakiroglou, C.D.; Theodoropoulou, M.A.; Karoutsos, V.

    2005-01-01

    In an attempt to investigate gravity effects on solute dispersion at the scale of a pore network, single source-solute transport visualization experiments are performed on glass-etched pore networks of varying morphology and degree of pore-scale heterogeneities. The (lighter) low solute concentration aqueous solution flows steadily through the porous medium and the (heavier) high solute concentration solution is injected at a very low and constant flow rate through an inner port. The transient evolution of the solute concentration distribution over various regions of the pore network is determined at different scales by capturing and video-recording snapshots of the dispersion on PC, measuring automatically the spatial variation of the color intensity of the solution, and transforming the color intensities to solute concentrations. Without the action of gravity, the steady-state dispersion regime changes with Peclet (Pe) number, and the longitudinal and transverse dispersivities are estimated by fitting the experimental datasets to approximate analytic solutions of the advection-dispersion equation. Under the action of gravity, multiple of steady-state solute dispersion regimes is developed at each Pe value, and lobe-shaped instabilities of the solute concentration are observed across the pore network, as the downward flow of the denser (higher solute concentration) fluid is counterbalanced by the upward flow of the less dense (lower solute concentration) fluid. The steady-state dispersion regimes may be periodic, quasi-periodic or chaotic depending on the system parameters. The nature of the transient fluctuations of the average solute concentration is analyzed by identifying the periodicity of the fluctuations, determining the autocorrelation function and the statistical moments of the time series, and inspecting the FFT (fast Fourier transform) power spectra. It is found that the mixing zone tends to be stabilized at higher values of the Peclet (Pe) number

  2. Behaviour of Strengthened RC Frames with Eccentric Steel Braced Frames

    Science.gov (United States)

    Kamanli, Mehmet; Unal, Alptug

    2017-10-01

    After devastating earthquakes in recent years, strengthening of reinforced concrete buildings became an important research topic. Reinforced concrete buildings can be strengthened by steel braced frames. These steel braced frames may be made of concentrically or eccentrically indicated in Turkish Earthquake Code 2007. In this study pushover analysis of the 1/3 scaled 1 reinforced concrete frame and 1/3 scaled 4 strengthened reinforced concrete frames with internal eccentric steel braced frames were conducted by SAP2000 program. According to the results of the analyses conducted, load-displacement curves of the specimens were compared and evaluated. Adding eccentric steel braces to the bare frame decreased the story drift, and significantly increased strength, stiffness and energy dissipation capacity. In this strengthening method lateral load carrying capacity, stiffness and dissipated energy of the structure can be increased.

  3. The human dimension of fire regimes on Earth.

    Science.gov (United States)

    Bowman, David M J S; Balch, Jennifer; Artaxo, Paulo; Bond, William J; Cochrane, Mark A; D'Antonio, Carla M; Defries, Ruth; Johnston, Fay H; Keeley, Jon E; Krawchuk, Meg A; Kull, Christian A; Mack, Michelle; Moritz, Max A; Pyne, Stephen; Roos, Christopher I; Scott, Andrew C; Sodhi, Navjot S; Swetnam, Thomas W; Whittaker, Robert

    2011-12-01

    Humans and their ancestors are unique in being a fire-making species, but 'natural' (i.e. independent of humans) fires have an ancient, geological history on Earth. Natural fires have influenced biological evolution and global biogeochemical cycles, making fire integral to the functioning of some biomes. Globally, debate rages about the impact on ecosystems of prehistoric human-set fires, with views ranging from catastrophic to negligible. Understanding of the diversity of human fire regimes on Earth in the past, present and future remains rudimentary. It remains uncertain how humans have caused a departure from 'natural' background levels that vary with climate change. Available evidence shows that modern humans can increase or decrease background levels of natural fire activity by clearing forests, promoting grazing, dispersing plants, altering ignition patterns and actively suppressing fires, thereby causing substantial ecosystem changes and loss of biodiversity. Some of these contemporary fire regimes cause substantial economic disruptions owing to the destruction of infrastructure, degradation of ecosystem services, loss of life, and smoke-related health effects. These episodic disasters help frame negative public attitudes towards landscape fires, despite the need for burning to sustain some ecosystems. Greenhouse gas-induced warming and changes in the hydrological cycle may increase the occurrence of large, severe fires, with potentially significant feedbacks to the Earth system. Improved understanding of human fire regimes demands: (1) better data on past and current human influences on fire regimes to enable global comparative analyses, (2) a greater understanding of different cultural traditions of landscape burning and their positive and negative social, economic and ecological effects, and (3) more realistic representations of anthropogenic fire in global vegetation and climate change models. We provide an historical framework to promote understanding

  4. The human dimension of fire regimes on Earth

    Science.gov (United States)

    Bowman, David M.J.S.; Balch, Jennifer; Artaxo, Paulo; Bond, William J.; Cochrane, Mark A.; D'Antonio, Carla M.; DeFries, Ruth; Johnston, Fay H.; Keeley, Jon E.; Krawchuk, Meg A.; Kull, Christian A.; Michelle, Mack; Moritz, Max A.; Pyne, Stephen; Roos, Christopher I.; Scott, Andrew C.; Sodhi, Navjot S.; Swetnam, Thomas W.

    2011-01-01

    Humans and their ancestors are unique in being a fire-making species, but 'natural' (i.e. independent of humans) fires have an ancient, geological history on Earth. Natural fires have influenced biological evolution and global biogeochemical cycles, making fire integral to the functioning of some biomes. Globally, debate rages about the impact on ecosystems of prehistoric human-set fires, with views ranging from catastrophic to negligible. Understanding of the diversity of human fire regimes on Earth in the past, present and future remains rudimentary. It remains uncertain how humans have caused a departure from 'natural' background levels that vary with climate change. Available evidence shows that modern humans can increase or decrease background levels of natural fire activity by clearing forests, promoting grazing, dispersing plants, altering ignition patterns and actively suppressing fires, thereby causing substantial ecosystem changes and loss of biodiversity. Some of these contemporary fire regimes cause substantial economic disruptions owing to the destruction of infrastructure, degradation of ecosystem services, loss of life, and smoke-related health effects. These episodic disasters help frame negative public attitudes towards landscape fires, despite the need for burning to sustain some ecosystems. Greenhouse gas-induced warming and changes in the hydrological cycle may increase the occurrence of large, severe fires, with potentially significant feedbacks to the Earth system. Improved understanding of human fire regimes demands: (1) better data on past and current human influences on fire regimes to enable global comparative analyses, (2) a greater understanding of different cultural traditions of landscape burning and their positive and negative social, economic and ecological effects, and (3) more realistic representations of anthropogenic fire in global vegetation and climate change models. We provide an historical framework to promote understanding

  5. Approximately dual frames in Hilbert spaces and applications to Gabor frames

    OpenAIRE

    Christensen, Ole; Laugesen, Richard S.

    2011-01-01

    Approximately dual frames are studied in the Hilbert space setting. Approximate duals are easier to construct than classical dual frames, and can be tailored to yield almost perfect reconstruction. Bounds on the deviation from perfect reconstruction are obtained for approximately dual frames constructed via perturbation theory. An alternative bound is derived for the rich class of Gabor frames, by using the Walnut representation of the frame operator to estimate the deviation from equality in...

  6. Framing the frame: How task goals determine the likelihood and direction of framing effects

    OpenAIRE

    Todd McElroy; John J. Seta

    2007-01-01

    We examined how the goal of a decision task influences the perceived positive, negative valence of the alternatives and thereby the likelihood and direction of framing effects. In Study 1 we manipulated the goal to increase, decrease or maintain the commodity in question and found that when the goal of the task was to increase the commodity, a framing effect consistent with those typically observed in the literature was found. When the goal was to decrease, a framing effect opposite to the ty...

  7. The PLC-based Industrial Temperature Control System: Design and Implementation

    Directory of Open Access Journals (Sweden)

    Wei Fanjie

    2017-01-01

    Full Text Available Targeting at the problem of slow response and low accuracy of the automatic temperature control system for material processing and boiler heating, a new design method is proposed to work with the PLC-based temperature control system, where the box temperature control may be achieved through the fan and the heating plate. The hardware design and software design of the system are analyzed in detail. In this paper, a combination of the traditional PID control and the more popular fuzzy control is taken as the control program to achieve the overall design of the control algorithm. Followed by the simulation in the MATLAB software, the designed system is highlighted by its the characteristics of impressive stability, precision and robustness.

  8. Development of multifunctional radiation monitoring instrument based on PLC technology

    International Nuclear Information System (INIS)

    Li Ziqiang; Zhu Yuye; Zhuang Min

    2007-01-01

    This eight-channel multifunctional Radiation Monitoring Instrument is developed by making use of the built-in high-speed counters and the powerful instruction system of the SIEMES SIMATICS S7 series Programmable Logic Controllers (PLC) to record and process the pulse signal output by the detectors. The instrument with functions, such as analog and digital display, digital storage of digital data, pulse signal generator, network communication, can connect various types of pulse detectors. The initial process can be translated between Graduation Apparatus method and Formula method. the logicality of the high-dosage warning system is processed itself. The signal output will drive the alarm lights and bell directly. This paper mainly describes the configuration, programming and feature of the instrument. (authors)

  9. British Nuclear Fuels PLC: report and accounts 1989-90

    International Nuclear Information System (INIS)

    1991-01-01

    Members of the Energy Select Committee put questions to representatives of British Nuclear Fuels PLC (BNFL) about the annual report and accounts 1989-90. Questions concerned the late publication of the accounts, BNFLs role in the downfall of the nuclear privatisation, government assistance to the nuclear industry, the price BNFL charges for fuel reprocessing and the process of laser isotope separation of uranium. The committee also asked about the rate of return in BNFL's assets as a percentage, Sellafield's potential as a site for a deep repository for radioactive wastes and the 6000 boreholes that MREX will drill at Sellafield. The commercial case for reprocessing is made. Feasibility studies for possible new reactions at Sellafield and Chapel Cross have been carried out. On the whole the Energy Committee were satisfied with the replies from BNFL. (UK)

  10. Mars Science Laboratory Frame Manager for Centralized Frame Tree Database and Target Pointing

    Science.gov (United States)

    Kim, Won S.; Leger, Chris; Peters, Stephen; Carsten, Joseph; Diaz-Calderon, Antonio

    2013-01-01

    The FM (Frame Manager) flight software module is responsible for maintaining the frame tree database containing coordinate transforms between frames. The frame tree is a proper tree structure of directed links, consisting of surface and rover subtrees. Actual frame transforms are updated by their owner. FM updates site and saved frames for the surface tree. As the rover drives to a new area, a new site frame with an incremented site index can be created. Several clients including ARM and RSM (Remote Sensing Mast) update their related rover frames that they own. Through the onboard centralized FM frame tree database, client modules can query transforms between any two frames. Important applications include target image pointing for RSM-mounted cameras and frame-referenced arm moves. The use of frame tree eliminates cumbersome, error-prone calculations of coordinate entries for commands and thus simplifies flight operations significantly.

  11. Electronic transitions and band offsets in C60:SubPc and C60:MgPc on MoO3 studied by modulated surface photovoltage spectroscopy

    International Nuclear Information System (INIS)

    Fengler, S.; Dittrich, Th.; Rusu, M.

    2015-01-01

    Electronic transitions at interfaces between MoO 3 layers and organic layers of C 60 , SubPc, MgPc, and nano-composite layers of SubPc:C 60 and MgPc:C 60 have been studied by modulated surface photovoltage (SPV) spectroscopy. For all systems, time dependent and modulated SPV signals pointed to dissociation of excitons at the MoO 3 /organic layer interfaces with a separation of holes towards MoO 3 . The highest occupied molecular orbital (HOMO)-lowest unoccupied molecular orbital (LUMO) gaps (E HL ) of C 60 , SubPc, and MgPc and the effective E HL of SubPc:C 60 and MgPc:C 60 were measured. The offsets between the LUMO (ΔE L ) or HOMO (ΔE H ) bands were obtained with high precision and amounted to 0.33 or 0.73 eV for SubPc:C 60 , respectively, and to −0.33 or 0.67 eV for MgPc:C 60 , respectively. Exponential tails below E HL and most pronounced sub-bandgap transitions were characterized and ascribed to disorder and transitions from HOMO bands to unoccupied defect states

  12. Behaviour of Strengthened RC Frames with Eccentric Steel Braced Frames

    Directory of Open Access Journals (Sweden)

    Kamanli Mehmet

    2017-01-01

    Full Text Available After devastating earthquakes in recent years, strengthening of reinforced concrete buildings became an important research topic. Reinforced concrete buildings can be strengthened by steel braced frames. These steel braced frames may be made of concentrically or eccentrically indicated in Turkish Earthquake Code 2007. In this study pushover analysis of the 1/3 scaled 1 reinforced concrete frame and 1/3 scaled 4 strengthened reinforced concrete frames with internal eccentric steel braced frames were conducted by SAP2000 program. According to the results of the analyses conducted, load-displacement curves of the specimens were compared and evaluated. Adding eccentric steel braces to the bare frame decreased the story drift, and significantly increased strength, stiffness and energy dissipation capacity. In this strengthening method lateral load carrying capacity, stiffness and dissipated energy of the structure can be increased.

  13. MHC class I signaling in T cells leads to tyrosine kinase activity and PLC-gamma 1 phosphorylation

    DEFF Research Database (Denmark)

    Skov, S; Odum, Niels; Claesson, M H

    1995-01-01

    phosphorylation and the subsequent calcium response. The early tyrosine kinase activity was found to be dependent on expression of the TCR/CD3 complex and the CD45 molecule on the surface of the T cells. Furthermore, MHC-I cross-linking was shown to tyrosine phosphorylate PLC-gamma 1 (phospholipase C-gamma 1...

  14. Experience using EPICS on PC platforms

    International Nuclear Information System (INIS)

    Hill, J.O.; Kasemire, K.U.

    1997-03-01

    The Experimental Physics and Industrial Control System (EPICS) has been widely adopted in the accelerator community. Although EPICS is available on many platforms, the majority of implementations have used UNIX workstations as clients, and VME- or VXI-based processors for distributed input output controllers. Recently, a significant portion of EPICS has been ported to personal computer (PC) hardware platforms running Microsoft's operating systems, and also Wind River System's real time vxWorks operating system. This development should significantly reduce the cost of deploying EPICS systems, and the prospect of using EPICS together with the many high quality commercial components available for PC platforms is also encouraging. A hybrid system using both PC and traditional platforms is currently being implemented at LANL for LEDA, the low energy demonstration accelerator under construction as part of the Accelerator Production of Tritium (APT) project. To illustrate these developments the authors compare their recent experience deploying a PC-based EPICS system with experience deploying similar systems based on traditional (UNIX-hosted) EPICS hardware and software platforms

  15. VirPLC: a Methodology to Developing Capacities, Skills and Self-esteem by the Logical Stimulus with a Simple, Functional and Dynamic Tool

    Directory of Open Access Journals (Sweden)

    Antoni FERRER ROJAS

    2017-07-01

    Full Text Available The proliferation of programming environments such as Logo, Minecraft, Code or Scratch is a consequence of the effectiveness of a graphic language for the introduction of students in programming but, some of the newer systems, such as App Inventor, are slow in the basic interaction: “make it” / “test it”. I propose an alternative for students from the age of 15. It is called VirPLC and it is oriented to something as functional as the systems control, through two screens: one with software to program and, another one with animated hardware to simulate it. VirPLC does not pretend to turn the user into an expert in automation, but to facilitate a first contact between the student and the logic world, by posing problems in practical, near and real control systems such as: crane control; TV competition; alarm; supermarket door; garage door; traffic light; lift... The student raises both the logical operativity, as well as the hardware requirements (inputs and outputs. The software works in an evolutionary and repeated way: “make it” / “test it” and consolidate to improve it. It allows the evolution in levels of greater complexity, where it is debugged until acquiring a solid “product”, functional, safe, versatile and installable. VirPLC step by step “hooks” students who pursue challenges and offers an alternative to apply after some Boolean Algebra notions, and before written programming, with objects, events and classes. VirPLC is freeware, it works under Windows (from XP to W10 and can be downloaded from the author’s WEB. At install time, it adds a folder with more than 30 examples often deliberately incomplete, along with a mini-course with several proposed practices.

  16. Multivariate wavelet frames

    CERN Document Server

    Skopina, Maria; Protasov, Vladimir

    2016-01-01

    This book presents a systematic study of multivariate wavelet frames with matrix dilation, in particular, orthogonal and bi-orthogonal bases, which are a special case of frames. Further, it provides algorithmic methods for the construction of dual and tight wavelet frames with a desirable approximation order, namely compactly supported wavelet frames, which are commonly required by engineers. It particularly focuses on methods of constructing them. Wavelet bases and frames are actively used in numerous applications such as audio and graphic signal processing, compression and transmission of information. They are especially useful in image recovery from incomplete observed data due to the redundancy of frame systems. The construction of multivariate wavelet frames, especially bases, with desirable properties remains a challenging problem as although a general scheme of construction is well known, its practical implementation in the multidimensional setting is difficult. Another important feature of wavelet is ...

  17. Changes in Teachers' Beliefs and Classroom Practices Concerning Inquiry-Based Instruction Following a Year-Long RET-PLC Program

    Science.gov (United States)

    Miranda, Rommel J.; Damico, Julie B.

    2015-01-01

    This mixed-methods study examines how engaging science teachers in a summer Research Experiences for Teachers (RET) followed by an academic-year Professional Learning Community (PLC) focused on translating teacher research experiences to inquiry-based classroom lessons might facilitate changes in their beliefs and classroom practices regarding…

  18. Integration of an open interface PC scene generator using COTS DVI converter hardware

    Science.gov (United States)

    Nordland, Todd; Lyles, Patrick; Schultz, Bret

    2006-05-01

    Commercial-Off-The-Shelf (COTS) personal computer (PC) hardware is increasingly capable of computing high dynamic range (HDR) scenes for military sensor testing at high frame rates. New electro-optical and infrared (EO/IR) scene projectors feature electrical interfaces that can accept the DVI output of these PC systems. However, military Hardware-in-the-loop (HWIL) facilities such as those at the US Army Aviation and Missile Research Development and Engineering Center (AMRDEC) utilize a sizeable inventory of existing projection systems that were designed to use the Silicon Graphics Incorporated (SGI) digital video port (DVP, also known as DVP2 or DD02) interface. To mate the new DVI-based scene generation systems to these legacy projection systems, CG2 Inc., a Quantum3D Company (CG2), has developed a DVI-to-DVP converter called Delta DVP. This device takes progressive scan DVI input, converts it to digital parallel data, and combines and routes color components to derive a 16-bit wide luminance channel replicated on a DVP output interface. The HWIL Functional Area of AMRDEC has developed a suite of modular software to perform deterministic real-time, wave band-specific rendering of sensor scenes, leveraging the features of commodity graphics hardware and open source software. Together, these technologies enable sensor simulation and test facilities to integrate scene generation and projection components with diverse pedigrees.

  19. Flow regimes

    International Nuclear Information System (INIS)

    Kh'yuitt, G.

    1980-01-01

    An introduction into the problem of two-phase flows is presented. Flow regimes arizing in two-phase flows are described, and classification of these regimes is given. Structures of vertical and horizontal two-phase flows and a method of their identification using regime maps are considered. The limits of this method application are discussed. The flooding phenomena and phenomena of direction change (flow reversal) of the flow and interrelation of these phenomena as well as transitions from slug regime to churn one and from churn one to annular one in vertical flows are described. Problems of phase transitions and equilibrium are discussed. Flow regimes in tubes where evaporating liquid is running, are described [ru

  20. Ion and solvent diffusion and ion conduction of PC-DEC and PC-DME binary solvent electrolytes of LiN(SO2CF3)2

    International Nuclear Information System (INIS)

    Hayamizu, Kikuko; Aihara, Yuichi

    2004-01-01

    Two binary mixed solvent systems typically used for lithium batteries were studied by measuring the self-diffusion coefficients of the solvent, lithium ion and anion, independently by using the multi-nuclear pulsed field-gradient spin-echo (PGSE) 1 H, 7 Li and 19 F NMR method. One system was propylene carbonate (PC) and diethyl carbonate (DEC) system and the other binary system was PC and 1,2-dimethoxyethane (DME), and the lithium salt used was LiN(SO 2 CF 3 ) 2 (LiTFSI). The relative ratio of the PC was changed from zero (pure DME and DEC) to 100% (pure PC) in the DME-PC and the DEC-PC systems, respectively. The self-diffusion coefficients of the solvents were measured with and without the lithium salt, and the two solvents had almost the same diffusion coefficient in the DEC-PC system, while DME diffused faster than PC in the DME-PC system. In the electrolytes the solvents diffused the fastest, followed by the anion with the lithium ion diffusing the slowest. The degree of ion dissociation was estimated for each electrolyte by comparing the ionic conductivities estimated from the ion diffusion and those measured directly by the electrochemical method

  1. Salinomycin Exerts Anticancer Effects on PC-3 Cells and PC-3-Derived Cancer Stem Cells In Vitro and In Vivo

    Directory of Open Access Journals (Sweden)

    Yunsheng Zhang

    2017-01-01

    Full Text Available Salinomycin is an antibiotic isolated from Streptomyces albus that selectively kills cancer stem cells (CSCs. However, the antitumor mechanism of salinomycin is unclear. This study investigated the chemotherapeutic efficacy of salinomycin in human prostate cancer PC-3 cells. We found that cytotoxicity of salinomycin to PC-3 cells was stronger than to nonmalignant prostate cell RWPE-1, and exposure to salinomycin induced G2/M phage arrest and apoptosis of PC-3 cells. A mechanistic study found salinomycin suppressed Wnt/β-catenin pathway to induce apoptosis of PC-3 cells. An in vivo experiment confirmed that salinomycin suppressed tumorigenesis in a NOD/SCID mice xenograft model generated from implanted PC-3 cells by inhibiting the Wnt/β-catenin pathway, since the total β-catenin protein level was reduced and the downstream target c-Myc level was significantly downregulated. We also showed that salinomycin, but not paclitaxel, triggered more apoptosis in aldehyde dehydrogenase- (ALDH- positive PC-3 cells, which were considered as the prostate cancer stem cells, suggesting that salinomycin may be a promising chemotherapeutic to target CSCs. In conclusion, this study suggests that salinomycin reduces resistance and relapse of prostate tumor by killing cancer cells as well as CSCs.

  2. PC based 8-parameter data acquisition system

    International Nuclear Information System (INIS)

    Gupta, J.D.; Naik, K.V.; Jain, S.K.; Pathak, R.V.; Suman, B.

    1989-01-01

    Multiparameter data acquisition (MPA) systems which analyse nuclear events with respect to more than one property of the event are essential tools for the study of some complex nuclear phenomena requiring analysis of time coincident spectra. For better throughput and accuracy each parameter is digitized by its own ADC. A stand alone low cost IBM PC based 8-parameter data acquisition system developed by the authors makes use of Address Recording technique for acquiring data from eight 12 bit ADC's in the PC Memory. Two memory buffers in the PC memory are used in ping-pong fashion so that data acquisition in one bank and dumping of data onto PC disk from the other bank can proceed simultaneously. Data is acquired in the PC memory through DMA mode for realising high throughput and hardware interrupt is used for switching banks for data acquisition. A comprehensive software package developed in Turbo-Pascal offers a set of menu-driven interactive commands to the user for setting-up system parameters and control of the system. The system is to be used with pelletron accelerator. (author). 5 figs

  3. Frames and outer frames for Hilbert C^*-modules

    OpenAIRE

    Arambašić, Ljiljana; Bakić, Damir

    2015-01-01

    The goal of the present paper is to extend the theory of frames for countably generated Hilbert $C^*$-modules over arbitrary $C^*$-algebras. In investigating the non-unital case we introduce the concept of outer frame as a sequence in the multiplier module $M(X)$ that has the standard frame property when applied to elements of the ambient module $X$. Given a Hilbert $\\A$-module $X$, we prove that there is a bijective correspondence of the set of all adjointable surjections from the generalize...

  4. Monte Carlo tests of the ELIPGRID-PC algorithm

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1995-04-01

    The standard tool for calculating the probability of detecting pockets of contamination called hot spots has been the ELIPGRID computer code of Singer and Wickman. The ELIPGRID-PC program has recently made this algorithm available for an IBM reg-sign PC. However, no known independent validation of the ELIPGRID algorithm exists. This document describes a Monte Carlo simulation-based validation of a modified version of the ELIPGRID-PC code. The modified ELIPGRID-PC code is shown to match Monte Carlo-calculated hot-spot detection probabilities to within ±0.5% for 319 out of 320 test cases. The one exception, a very thin elliptical hot spot located within a rectangular sampling grid, differed from the Monte Carlo-calculated probability by about 1%. These results provide confidence in the ability of the modified ELIPGRID-PC code to accurately predict hot-spot detection probabilities within an acceptable range of error

  5. A water pumping control system with a programmable logic controller (PLC) and industrial wireless modules for industrial plants--an experimental setup.

    Science.gov (United States)

    Bayindir, Ramazan; Cetinceviz, Yucel

    2011-04-01

    This paper describes a water pumping control system that is designed for production plants and implemented in an experimental setup in a laboratory. These plants contain harsh environments in which chemicals, vibrations or moving parts exist that could potentially damage the cabling or wires that are part of the control system. Furthermore, the data has to be transferred over paths that are accessible to the public. The control systems that it uses are a programmable logic controller (PLC) and industrial wireless local area network (IWLAN) technologies. It is implemented by a PLC, an communication processor (CP), two IWLAN modules, and a distributed input/output (I/O) module, as well as the water pump and sensors. Our system communication is based on an Industrial Ethernet and uses the standard Transport Control Protocol/Internet Protocol for parameterisation, configuration and diagnostics. The main function of the PLC is to send a digital signal to the water pump to turn it on or off, based on the tank level, using a pressure transmitter and inputs from limit switches that indicate the level of the water in the tank. This paper aims to provide a convenient solution in process plants where cabling is not possible. It also has lower installation and maintenance cost, provides reliable operation, and robust and flexible construction, suitable for industrial applications. Copyright © 2010 ISA. Published by Elsevier Ltd. All rights reserved.

  6. On frame multiresolution analysis

    DEFF Research Database (Denmark)

    Christensen, Ole

    2003-01-01

    We use the freedom in frame multiresolution analysis to construct tight wavelet frames (even in the case where the refinable function does not generate a tight frame). In cases where a frame multiresolution does not lead to a construction of a wavelet frame we show how one can nevertheless...

  7. Synchronization in a PLC/VAX-based control and data-acquisition system of a nuclear-fusion experiment

    International Nuclear Information System (INIS)

    Schmidt, V.; Flor, G.; Hemming, O.N.; Luchetta, A.; Manduchi, G.; Vitturi, S.

    1990-01-01

    This paper describes the concept and implementation details of the synchronization mechanisms used in the control and data-acquisition system of the RFX (Reversed-Field Experiment) nuclear-fusion experimental device, at present under construction in Padova, Italy, within the framework of the co-ordinated nuclear-fusion research programme of the European Communities. The system employs industrial PLCs for the 'slow' control and monitoring functions, and a VAX-based CAMAC for the 'fast' functions of trigger-signal generation and data acquisition during the experiment pulses. All subsystems communicate via Ethernet, using compatible software protocols. The operational sequence of the complete system is governed by a single state machine implemented on a PLC-based supervisor system. Equivalent 'slave' state machines are implemented on all other subsystems (PLC- and VAX-based). These state machines are synchronized by means of the exchange of messages via Ethernet. This paper deals in detail with the following components which are involved in system synchronization: The Message Exchange System which implements the system-wide exchange of short messages; the Scheduler programs which implement the state machine on the various computing nodes, and which make use of the Message Exchange System. (orig.)

  8. Quality of Non-Interest Banking Services and Customers’ Satisfaction: Evidence from Jaiz Bank PLC, Kaduna, Nigeria

    Directory of Open Access Journals (Sweden)

    Yusuf Ismaila Mustapha

    2017-02-01

    Full Text Available The dwindling levels of service quality in Nigerian financial institutions had resulted in abysmal performance of most banks and other financial institutions in the sector and this challenge has made it imperative for financial firms to be customer centered in all their operational activities. The purpose of this study is to determine the effect of service quality of non-interest bank on customers’ satisfaction using Jaiz Bank PLC, Kaduna as a case study. The study utilized convenience and snowball sampling techniques to select 147 customers who served as respondents in the study. Correlation and multiple regression analysis were employed as analytical techniques. The results show that compliance with Islamic laws is highly correlated with customer satisfaction which was followed respectively by assurance, reliability, tangibility, responsiveness and empathy dimensions. It was also discovered that the six service quality dimensions significantly influenced the satisfaction of Jaiz Bank Plc, Kaduna branch customers’. The study recommends that management of the bank should exploit and maneuver the service quality dimensions as a survival strategy for improving customers’ satisfaction in an industry characterized by intense competition and environmental dynamism.

  9. High-speed three-frame image recording system using colored flash units and low-cost video equipment

    Science.gov (United States)

    Racca, Roberto G.; Scotten, Larry N.

    1995-05-01

    This article describes a method that allows the digital recording of sequences of three black and white images at rates of several thousand frames per second using a system consisting of an ordinary CCD camcorder, three flash units with color filters, a PC-based frame grabber board and some additional electronics. The maximum framing rate is determined by the duration of the flashtube emission, and for common photographic flash units lasting about 20 microsecond(s) it can exceed 10,000 frames per second in actual use. The subject under study is strobe- illuminated using a red, a green and a blue flash unit controlled by a special sequencer, and the three images are captured by a color CCD camera on a single video field. Color is used as the distinguishing parameter that allows the overlaid exposures to be resolved. The video output for that particular field will contain three individual scenes, one for each primary color component, which potentially can be resolved with no crosstalk between them. The output is electronically decoded into the primary color channels, frame grabbed and stored into digital memory, yielding three time-resolved images of the subject. A synchronization pulse provided by the flash sequencer triggers the frame grabbing so that the correct video field is acquired. A scheme involving the use of videotape as intermediate storage allows the frame grabbing to be performed using a monochrome video digitizer. Ideally each flash- illuminated scene would be confined to one color channel, but in practice various factors, both optical and electronic, affect color separation. Correction equations have been derived that counteract these effects in the digitized images and minimize 'ghosting' between frames. Once the appropriate coefficients have been established through a calibration procedure that needs to be performed only once for a given configuration of the equipment, the correction process is carried out transparently in software every time a

  10. La automática en aplicaciones industriales

    OpenAIRE

    Ipanaque Alama, William; Vásquez Díaz, Edilberto

    1993-01-01

    Las plantas industriales disponen hoy día de herramientas eficientes informáticas y electrónicas que permiten automatizar sus procesos. Una de estas herramientas ha sido el controlador lógico programable (PLC) y el microcomputador (PC).

  11. Poster session ELIPGRID-PC

    International Nuclear Information System (INIS)

    Davidson, J.R.

    1995-01-01

    ELIPGRID-PC, a new personal computer program, has been developed to provide easy access to Singer's ELIPGRID algorithm for hot-spot detection probabilities. Three features of the program are the ability to determine: (1) the grid size required for specified conditions, (2) the smallest hot spot that can be sampled with a given probability, and (3) the approximate grid size resulting from specified conditions and sampling cost. ELIPGRID-PC also provides probability of detection versus cost data for graphing with spreadsheets or graphics software. The program has been successfully tested using Singer's published ELIPGRID results. An apparent error in the published ELIPGRID code has been uncovered and an appropriate modification incorporated into the new program

  12. PEMBUATAN SISTEM KONTROL MESIN CAULKING ROD GUIDE OTOMATIS MENGGUNAKAN PLC OMRON CPM1A

    Directory of Open Access Journals (Sweden)

    Syahril Ardi

    2015-02-01

    Full Text Available Kenaikan tingkat produksi shock absorber perusahaan manufaktur membuat proses produksi harus berjalan dengan baik . Pipa proses pemotongan pada mendempul panduan mesin batang memiliki beberapa masalah yang harus diatasi . Untuk mengatasi masalah tersebut kemudian melakukan modifikasi mesin batang mendempul yang secara otomatis dapat mengurangi waktu siklus pada proses mendempul batang dari 4,5 detik per potong sehingga tingkat produksi memotong garis pipa dapat ditingkatkan . Sistem kontrol otomatis mendempul mesin batang panduan ini dirancang untuk menggunakan Programmable Logic Controller (PLC

  13. A Component-Based Modeling and Validation Method for PLC Systems

    Directory of Open Access Journals (Sweden)

    Rui Wang

    2014-05-01

    Full Text Available Programmable logic controllers (PLCs are complex embedded systems that are widely used in industry. This paper presents a component-based modeling and validation method for PLC systems using the behavior-interaction-priority (BIP framework. We designed a general system architecture and a component library for a type of device control system. The control software and hardware of the environment were all modeled as BIP components. System requirements were formalized as monitors. Simulation was carried out to validate the system model. A realistic example from industry of the gates control system was employed to illustrate our strategies. We found a couple of design errors during the simulation, which helped us to improve the dependability of the original systems. The results of experiment demonstrated the effectiveness of our approach.

  14. Framed School--Frame Factors, Frames and the Dynamics of Social Interaction in School

    Science.gov (United States)

    Persson, Anders

    2015-01-01

    This paper aims to show how the Goffman frame perspective can be used in an analysis of school and education and how it can be combined, in such analysis, with the frame factor perspective. The latter emphasizes factors that are determined outside the teaching process, while the former stresses how actors organize their experiences and define…

  15. PC-Reactor-core transient simulation code

    International Nuclear Information System (INIS)

    Nakata, H.

    1989-10-01

    PC-REATOR, a reactor core transient simulation code has been developed for the real-time operator training on a IBM-PC microcomputer. The program presents capabilities for on-line exchange of the operating parameters during the transient simulation, by friendly keyboard instructions. The model is based on the point-kinetics approximation, with 2 delayed neutron percursors and up to 11 decay power generating groups. (author) [pt

  16. The putative endoglucanase PcGH61D from Phanerochaete chrysosporium is a metal-dependent oxidative enzyme that cleaves cellulose.

    Directory of Open Access Journals (Sweden)

    Bjørge Westereng

    Full Text Available Many fungi growing on plant biomass produce proteins currently classified as glycoside hydrolase family 61 (GH61, some of which are known to act synergistically with cellulases. In this study we show that PcGH61D, the gene product of an open reading frame in the genome of Phanerochaete chrysosporium, is an enzyme that cleaves cellulose using a metal-dependent oxidative mechanism that leads to generation of aldonic acids. The activity of this enzyme and its beneficial effect on the efficiency of classical cellulases are stimulated by the presence of electron donors. Experiments with reduced cellulose confirmed the oxidative nature of the reaction catalyzed by PcGH61D and indicated that the enzyme may be capable of penetrating into the substrate. Considering the abundance of GH61-encoding genes in fungi and genes encoding their functional bacterial homologues currently classified as carbohydrate binding modules family 33 (CBM33, this enzyme activity is likely to turn out as a major determinant of microbial biomass-degrading efficiency.

  17. Network-based H.264/AVC whole frame loss visibility model and frame dropping methods.

    Science.gov (United States)

    Chang, Yueh-Lun; Lin, Ting-Lan; Cosman, Pamela C

    2012-08-01

    We examine the visual effect of whole frame loss by different decoders. Whole frame losses are introduced in H.264/AVC compressed videos which are then decoded by two different decoders with different common concealment effects: frame copy and frame interpolation. The videos are seen by human observers who respond to each glitch they spot. We found that about 39% of whole frame losses of B frames are not observed by any of the subjects, and over 58% of the B frame losses are observed by 20% or fewer of the subjects. Using simple predictive features which can be calculated inside a network node with no access to the original video and no pixel level reconstruction of the frame, we developed models which can predict the visibility of whole B frame losses. The models are then used in a router to predict the visual impact of a frame loss and perform intelligent frame dropping to relieve network congestion. Dropping frames based on their visual scores proves superior to random dropping of B frames.

  18. Framing Failures in Wood-Frame Hip Roofs under Extreme Wind Loads

    Directory of Open Access Journals (Sweden)

    Sarah A. Stevenson

    2018-02-01

    Full Text Available Wood-frame residential roof failures are among the most common and expensive types of wind damage. Hip roofs are commonly understood to be more resilient during extreme wind in relation to gable roofs. However, inspection of damage survey data from recent tornadoes has revealed a previously unstudied failure mode in which hip roofs suffer partial failure of the framing structure. In the current study, evidence of partial framing failures and statistics of their occurrence are explored and discussed, while the common roof design and construction practice are reviewed. Two-dimensional finite element models are developed to estimate the element-level load effects on hip roof trusses and stick-frame components. The likelihood of failure in each member is defined based on relative demand-to-capacity ratios. Trussed and stick-frame structures are compared to assess the relative performance of the two types of construction. The present analyses verify the common understanding that toenailed roof-to-wall connections are likely to be the most vulnerable elements in the structure of a wood-frame hip roof. However, the results also indicate that certain framing members and connections display significant vulnerability under the same wind uplift, and the possibility of framing failure is not to be discounted. Furthermore, in the case where the roof-to-wall connection uses hurricane straps, certain framing members and joints become the likely points of failure initiation. The analysis results and damage survey observations are used to expand the understanding of wood-frame residential roof failures, as they relate to the Enhanced Fujita Scale and provide assessment of potential gaps in residential design codes.

  19. Hukum Lingkungan dan Pertanggungjawaban Strict Liability dalam Sistem Hukum Common Law (Studi Kasus Cambridge Water Co. Ltd v. Eastern Countries Leather Plc

    Directory of Open Access Journals (Sweden)

    Mahfud Mahfud

    2010-12-01

    Full Text Available ABSTRACT: The possibilities for pollution control still offered today Blackburn J.’s celebrated rule of strict liability, now almost 130 years old, has ensured its continuing popularity. There can be few tort lawyers, however, who have not increasingly wondered how much time should be devoted to a case which has received little judicial attention in recent years, and which was last subjected to detailed consideration by the House of Lords nearly 50 years ago, until, that is, the much-published decision of the House of Lords in Cambridge Water Co. Ltd v. Eastern Countries Leather Plc.   (Environmental Law and The Strict Liability Application In the Common Law System (The Case Study of Cambridge Water Co. Ltd V. Eastern Countries Leather Plc

  20. When message-frame fits salient cultural-frame, messages feel more persuasive

    OpenAIRE

    Uskul, Ayse K.; Oyserman, Daphna

    2010-01-01

    The present study examines the persuasive effects of tailored health messages comparing those tailored to match (versus not match) both chronic cultural frame and momentarily salient cultural frame. Evidence from two studies (Study 1: n = 72 European Americans; Study 2: n = 48 Asian Americans) supports the hypothesis that message persuasiveness increases when chronic cultural frame, health message tailoring and momentarily salient cultural frame all match. The hypothesis was tested using a me...